Sample records for test results based

  1. The predictive value of the sacral base pressure test in detecting specific types of sacroiliac dysfunction

    PubMed Central

    Mitchell, Travis D.; Urli, Kristina E.; Breitenbach, Jacques; Yelverton, Chris

    2007-01-01

    Abstract Objective This study aimed to evaluate the validity of the sacral base pressure test in diagnosing sacroiliac joint dysfunction. It also determined the predictive powers of the test in determining which type of sacroiliac joint dysfunction was present. Methods This was a double-blind experimental study with 62 participants. The results from the sacral base pressure test were compared against a cluster of previously validated tests of sacroiliac joint dysfunction to determine its validity and predictive powers. The external rotation of the feet, occurring during the sacral base pressure test, was measured using a digital inclinometer. Results There was no statistically significant difference in the results of the sacral base pressure test between the types of sacroiliac joint dysfunction. In terms of the results of validity, the sacral base pressure test was useful in identifying positive values of sacroiliac joint dysfunction. It was fairly helpful in correctly diagnosing patients with negative test results; however, it had only a “slight” agreement with the diagnosis for κ interpretation. Conclusions In this study, the sacral base pressure test was not a valid test for determining the presence of sacroiliac joint dysfunction or the type of dysfunction present. Further research comparing the agreement of the sacral base pressure test or other sacroiliac joint dysfunction tests with a criterion standard of diagnosis is necessary. PMID:19674694

  2. Physical Test Prototypes Based on Microcontroller

    NASA Astrophysics Data System (ADS)

    Paramitha, S. T.

    2017-03-01

    The purpose of this study was to produce a prototype of a physical test-based microcontroller. The research method uses the research and development of the Borg and gall. The procedure starts from the study; research and information collecting, planning, develop preliminary form of product, preliminary field testing, main product revision, playing field testing, operational product revision, field operational testing, final product revision, dissemination and implementation. Validation of the product, obtained through expert evaluation; test products of small scale and large scale; effectiveness test; evaluation of respondents. The results showed that the eligibility assessment of prototype products based physical tests microcontroller. Based on the ratings of seven experts showed that 87% included in the category of “very good” and 13% included in the category of “good”. While the effectiveness of the test results showed that 1). The results of the experimental group to test sit-ups increase by 40% and the control group by 15%. 2). The results of the experimental group to test push-ups increased by 30% and the control group by 10%. 3). The results of the experimental group to test the Back-ups increased by 25% and the control group by 10%. With a significant value of 0.002 less than 0.05, product means a physical test prototype microcontroller based, proven effective in improving the results of physical tests. Conclusions and recommendations; Product physical microcontroller-based assays, can be used to measure the physical tests of pushups, sit ups, and back-ups.

  3. In Situ Biological Treatment Test at Kelly Air Force Base. Volume 2. Field Test Results and Cost Model

    DTIC Science & Technology

    1987-07-01

    Groundwater." Developments in Industrial Microbiology, Volume 24, pp. 225-234. Society of Industrial Microbiology, Arlington, Virginia. 18. Product ...ESL-TR-85-52 cv) VOLUME II CN IN SITU BIOLOGICAL TREATMENT TEST AT KELLY AIR FORCE BASE, VOLUME !1: FIELD TEST RESULTS AND COST MODEL R.S. WETZEL...Kelly Air Force Base, Volume II: Field Test Results and Cost Model (UNCLASSIFIED) 12 PERSONAL AUTHOR(S) Roger S. Wetzel, Connie M. Durst, Donald H

  4. Introducing Computer-Based Testing in High-Stakes Exams in Higher Education: Results of a Field Experiment.

    PubMed

    Boevé, Anja J; Meijer, Rob R; Albers, Casper J; Beetsma, Yta; Bosker, Roel J

    2015-01-01

    The introduction of computer-based testing in high-stakes examining in higher education is developing rather slowly due to institutional barriers (the need of extra facilities, ensuring test security) and teacher and student acceptance. From the existing literature it is unclear whether computer-based exams will result in similar results as paper-based exams and whether student acceptance can change as a result of administering computer-based exams. In this study, we compared results from a computer-based and paper-based exam in a sample of psychology students and found no differences in total scores across the two modes. Furthermore, we investigated student acceptance and change in acceptance of computer-based examining. After taking the computer-based exam, fifty percent of the students preferred paper-and-pencil exams over computer-based exams and about a quarter preferred a computer-based exam. We conclude that computer-based exam total scores are similar as paper-based exam scores, but that for the acceptance of high-stakes computer-based exams it is important that students practice and get familiar with this new mode of test administration.

  5. A comparison of paper-and-pencil and computerized forms of Line Orientation and Enhanced Cued Recall Tests.

    PubMed

    Aşkar, Petek; Altun, Arif; Cangöz, Banu; Cevik, Vildan; Kaya, Galip; Türksoy, Hasan

    2012-04-01

    The purpose of this study was to assess whether a computerized battery of neuropsychological tests could produce similar results as the conventional forms. Comparisons on 77 volunteer undergraduates were carried out with two neuropsychological tests: Line Orientation Test and Enhanced Cued Recall Test. Firstly, students were assigned randomly across the test medium (paper-and-pencil versus computerized). Secondly, the groups were given the same test in the other medium after a 30-day interval between tests. Results showed that the Enhanced Cued Recall Test-Computer-based did not correlate with the Enhanced Cued Recall Test-Paper-and-pencil results. Line Orientation Test-Computer-based scores, on the other hand, did correlate significantly with the Line Orientation Test-Paper-and-pencil version. In both tests, scores were higher on paper-and-pencil tests compared to computer-based tests. Total score difference between modalities was statistically significant for both Enhanced Cued Recall Tests and for the Line Orientation Test. In both computer-based tests, it took less time for participants to complete the tests.

  6. Home-Based HIV Testing for Men Who Have Sex with Men in China: A Novel Community-Based Partnership to Complement Government Programs

    PubMed Central

    Qian, Han-Zhu; Wang, Li-Juan; Zhang, Zheng; Ding, Hai-Feng; Ji, Ya-Cheng; Li, Dong-liang; Xiao, Dong; Hazlitt, Melissa; Vermund, Sten H.; Xiu, Xiangfei; Bao, Yugang

    2014-01-01

    Background The coverage of HIV testing among Chinese men who have sex with men (MSM) remains low after the scale-up of free HIV testing at government-sponsored testing sites. We evaluated the feasibility of home-based HIV self-testing and the willingness to be HIV tested at community-based organizations (CBO). Methods We recruited MSM via on-line advertisement, where they completed an on-line informed consent and subsequent questionnaire survey. Eligible MSM received HIV rapid testing kits by mail, performed the test themselves and reported the result remotely. Results Of the 220 men taking a home-based HIV self-testing, 33 MSM (15%) were seropositive. Nearly 65% of the men reported that they were willing to take HIV testing at CBO, while 28% preferred receiving free HIV testing in the government programs at local Centers for Disease Control and Prevention (CDC). Older and lower-income MSM, those who self-reported homosexual orientation, men with no history of sexually transmitted diseases and a lower number of sexual partners in the past six months were associated with preference for taking HIV testing at CBOs. The top three self-reported existing barriers for HIV testing were: no perception of HIV risk (56%), fear of an HIV positive result being reported to the government (41%), and fear of a positive HIV test result (36%). Conclusion Home-based HIV self-testing is an alternative approach for increasing the coverage of HIV testing among Chinese MSM. CBO-based HIV testing is a potential alternative, but further studies are needed to evaluate its feasibility. PMID:25051160

  7. Oxygen demand of aircraft and airfield pavement deicers and alternative freezing point depressants

    USGS Publications Warehouse

    Corsi, Steven R.; Mericas, Dean; Bowman, George

    2012-01-01

    Aircraft and pavement deicing formulations and other potential freezing point depressants were tested for biochemical oxygen demand (BOD) and chemical oxygen demand (COD). Propylene glycol-based aircraft deicers exhibited greater BOD5 than ethylene glycol-based aircraft deicers, and ethylene glycol-based products had lower degradation rates than propylene glycol-based products. Sodium formate pavement deicers had lower COD than acetate-based pavement deicers. The BOD and COD results for acetate-based pavement deicers (PDMs) were consistently lower than those for aircraft deicers, but degradation rates were greater in the acetate-based PDM than in aircraft deicers. In a 40-day testing of aircraft and pavement deicers, BOD results at 20°C (standard) were consistently greater than the results from 5°C (low) tests. The degree of difference between standard and low temperature BOD results varied among tested products. Freshwater BOD test results were not substantially different from marine water tests at 20°C, but glycols degraded slower in marine water than in fresh water for low temperature tests. Acetate-based products had greater percentage degradation than glycols at both temperatures. An additive component of the sodium formate pavement deicer exhibited toxicity to the microorganisms, so BOD testing did not work properly for this formulation. BOD testing of alternative freezing point depressants worked well for some, there was little response for some, and for others there was a lag in response while microorganisms acclimated to the freezing point depressant as a food source. Where the traditional BOD5 test performed adequately, values ranged from 251 to 1,580 g/kg. Where the modified test performed adequately, values of BOD28 ranged from 242 to 1,540 g/kg.

  8. Space Launch System Base Heating Test: Experimental Operations & Results

    NASA Technical Reports Server (NTRS)

    Dufrene, Aaron; Mehta, Manish; MacLean, Matthew; Seaford, Mark; Holden, Michael

    2016-01-01

    NASA's Space Launch System (SLS) uses four clustered liquid rocket engines along with two solid rocket boosters. The interaction between all six rocket exhaust plumes will produce a complex and severe thermal environment in the base of the vehicle. This work focuses on a recent 2% scale, hot-fire SLS base heating test. These base heating tests are short-duration tests executed with chamber pressures near the full-scale values with gaseous hydrogen/oxygen engines and RSRMV analogous solid propellant motors. The LENS II shock tunnel/Ludwieg tube tunnel was used at or near flight duplicated conditions up to Mach 5. Model development was based on the Space Shuttle base heating tests with several improvements including doubling of the maximum chamber pressures and duplication of freestream conditions. Test methodology and conditions are presented, and base heating results from 76 runs are reported in non-dimensional form. Regions of high heating are identified and comparisons of various configuration and conditions are highlighted. Base pressure and radiometer results are also reported.

  9. S-2 stage 1/25 scale model base region thermal environment test. Volume 1: Test results, comparison with theory and flight data

    NASA Technical Reports Server (NTRS)

    Sadunas, J. A.; French, E. P.; Sexton, H.

    1973-01-01

    A 1/25 scale model S-2 stage base region thermal environment test is presented. Analytical results are included which reflect the effect of engine operating conditions, model scale, turbo-pump exhaust gas injection on base region thermal environment. Comparisons are made between full scale flight data, model test data, and analytical results. The report is prepared in two volumes. The description of analytical predictions and comparisons with flight data are presented. Tabulation of the test data is provided.

  10. Automated Low-Cost Smartphone-Based Lateral Flow Saliva Test Reader for Drugs-of-Abuse Detection.

    PubMed

    Carrio, Adrian; Sampedro, Carlos; Sanchez-Lopez, Jose Luis; Pimienta, Miguel; Campoy, Pascual

    2015-11-24

    Lateral flow assay tests are nowadays becoming powerful, low-cost diagnostic tools. Obtaining a result is usually subject to visual interpretation of colored areas on the test by a human operator, introducing subjectivity and the possibility of errors in the extraction of the results. While automated test readers providing a result-consistent solution are widely available, they usually lack portability. In this paper, we present a smartphone-based automated reader for drug-of-abuse lateral flow assay tests, consisting of an inexpensive light box and a smartphone device. Test images captured with the smartphone camera are processed in the device using computer vision and machine learning techniques to perform automatic extraction of the results. A deep validation of the system has been carried out showing the high accuracy of the system. The proposed approach, applicable to any line-based or color-based lateral flow test in the market, effectively reduces the manufacturing costs of the reader and makes it portable and massively available while providing accurate, reliable results.

  11. 9 CFR 149.6 - Slaughter facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... result based on an ELISA method and is confirmed positive by further testing using the digestion method... decertified. (C) If a test sample yields a positive test result based on an ELISA method, but is not confirmed...

  12. 9 CFR 149.6 - Slaughter facilities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... result based on an ELISA method and is confirmed positive by further testing using the digestion method... decertified. (C) If a test sample yields a positive test result based on an ELISA method, but is not confirmed...

  13. 9 CFR 149.6 - Slaughter facilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... result based on an ELISA method and is confirmed positive by further testing using the digestion method... decertified. (C) If a test sample yields a positive test result based on an ELISA method, but is not confirmed...

  14. 9 CFR 149.6 - Slaughter facilities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... result based on an ELISA method and is confirmed positive by further testing using the digestion method... decertified. (C) If a test sample yields a positive test result based on an ELISA method, but is not confirmed...

  15. 9 CFR 149.6 - Slaughter facilities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... result based on an ELISA method and is confirmed positive by further testing using the digestion method... decertified. (C) If a test sample yields a positive test result based on an ELISA method, but is not confirmed...

  16. Acceptability of self-conducted home-based HIV testing among men who have sex with men in Brazil: data from an on-line survey

    PubMed Central

    Lippman, Sheri A.; Périssé, André R. S.; Veloso, Valdiléa G.; Sullivan, Patrick S.; Buchbinder, Susan; Sineath, R. Craig; Grinsztejn, Beatriz

    2014-01-01

    The Brazilian HIV/AIDS epidemic is concentrated among men who have sex with men (MSM), however HIV testing rates among MSM are not commensurate with their risk. Strategies to expand early diagnosis may include use of self-conducted home-based testing kits, which are now available for purchase in the US. In April 2011 we conducted a survey with Brazilian MSM using Facebook to assess HIV testing preferences and acceptability of home-based testing. Among 356 previously tested, HIV-negative MSM, 47% reported a preference for home-based testing, 27% preferred clinic-based testing, and 26% had no preference. Less frequent testers and those who had considered testing but failed to test were more likely to prefer home-based testing. Close to 90% reported that they would use self-test kits; 62% and 54% said they would use home-based testing to make choices about unprotected sex with regular and new partners, respectively. Concerns included difficulty to understand the tests (32%) and receiving results alone (23%). Overall, home-based testing may appeal to MSM and result in increased testing frequency. Research on feasibility and utilization of self-tests in practice is needed. PMID:24896048

  17. Introducing Computer-Based Testing in High-Stakes Exams in Higher Education: Results of a Field Experiment

    PubMed Central

    Boevé, Anja J.; Meijer, Rob R.; Albers, Casper J.; Beetsma, Yta; Bosker, Roel J.

    2015-01-01

    The introduction of computer-based testing in high-stakes examining in higher education is developing rather slowly due to institutional barriers (the need of extra facilities, ensuring test security) and teacher and student acceptance. From the existing literature it is unclear whether computer-based exams will result in similar results as paper-based exams and whether student acceptance can change as a result of administering computer-based exams. In this study, we compared results from a computer-based and paper-based exam in a sample of psychology students and found no differences in total scores across the two modes. Furthermore, we investigated student acceptance and change in acceptance of computer-based examining. After taking the computer-based exam, fifty percent of the students preferred paper-and-pencil exams over computer-based exams and about a quarter preferred a computer-based exam. We conclude that computer-based exam total scores are similar as paper-based exam scores, but that for the acceptance of high-stakes computer-based exams it is important that students practice and get familiar with this new mode of test administration. PMID:26641632

  18. Preferences for Home-Based HIV Testing Among Heterosexuals at Increased Risk for HIV/AIDS: New Orleans, Louisiana, 2013.

    PubMed

    Robinson, William T; Zarwell, Meagan; Gruber, DeAnn

    2017-07-01

    Participants in the New Orleans arm of the National HIV Behavioral Surveillance of Heterosexuals at Increased Risk for HIV were asked about potential utilization of self-administered home-based tests for HIV. The majority (86%) would use a free home-based test if provided by mail and 99% would seek treatment based on a positive result. In addition, more than half of respondents would return test results in some format to the test provider, whereas most of the remaining participants preferred to discuss results only with their doctor. These findings point toward a potential method for advancing the National HIV/AIDS Strategy.

  19. The Effects of Web-Based Patient Access to Laboratory Results in British Columbia: A Patient Survey on Comprehension and Anxiety.

    PubMed

    Mák, Geneviève; Smith Fowler, Heather; Leaver, Chad; Hagens, Simon; Zelmer, Jennifer

    2015-08-04

    Web-based patient access to personal health information is limited but increasing in Canada and internationally. This exploratory study aimed to increase understanding of how Web-based access to laboratory test results in British Columbia (Canada), which has been broadly available since 2010, affects patients' experiences. In November 2013, we surveyed adults in British Columbia who had had a laboratory test in the previous 12 months. Using a retrospective cohort design, we compared reported wait-time for results, test result comprehension, and anxiety levels of "service users" who had Web-based access to their test results (n=2047) with those of a general population panel that did not have Web-based access (n=1245). The vast majority of service users (83.99%, 95% CI 82.31-85.67) said they received their results within "a few days", compared to just over a third of the comparison group (37.84%, 95% CI 34.96-40.73). Most in both groups said they understood their test results, but the rate was lower for service users than the comparison group (75.55%, 95% CI 73.58-77.49 vs 84.69%, 95% CI 82.59-86.81). There was no significant difference between groups in levels of reported anxiety after receiving test results. While most patients who received their laboratory test results online reported little anxiety after receiving their results and were satisfied with the service, there may be opportunities to improve comprehension of results.

  20. Effects of Concept Map Extraction and a Test-Based Diagnostic Environment on Learning Achievement and Learners' Perceptions

    ERIC Educational Resources Information Center

    Lin, Yu-Shih; Chang, Yi-Chun; Liew, Keng-Hou; Chu, Chih-Ping

    2016-01-01

    Computerised testing and diagnostics are critical challenges within an e-learning environment, where the learners can assess their learning performance through tests. However, a test result based on only a single score is insufficient information to provide a full picture of learning performance. In addition, because test results implicitly…

  1. Home-based HIV testing for men who have sex with men in China: a novel community-based partnership to complement government programs.

    PubMed

    Tao, Jun; Li, Ming-ying; Qian, Han-Zhu; Wang, Li-Juan; Zhang, Zheng; Ding, Hai-Feng; Ji, Ya-Cheng; Li, Dong-liang; Xiao, Dong; Hazlitt, Melissa; Vermund, Sten H; Xiu, Xiangfei; Bao, Yugang

    2014-01-01

    The coverage of HIV testing among Chinese men who have sex with men (MSM) remains low after the scale-up of free HIV testing at government-sponsored testing sites. We evaluated the feasibility of home-based HIV self-testing and the willingness to be HIV tested at community-based organizations (CBO). We recruited MSM via on-line advertisement, where they completed an on-line informed consent and subsequent questionnaire survey. Eligible MSM received HIV rapid testing kits by mail, performed the test themselves and reported the result remotely. Of the 220 men taking a home-based HIV self-testing, 33 MSM (15%) were seropositive. Nearly 65% of the men reported that they were willing to take HIV testing at CBO, while 28% preferred receiving free HIV testing in the government programs at local Centers for Disease Control and Prevention (CDC). Older and lower-income MSM, those who self-reported homosexual orientation, men with no history of sexually transmitted diseases and a lower number of sexual partners in the past six months were associated with preference for taking HIV testing at CBOs. The top three self-reported existing barriers for HIV testing were: no perception of HIV risk (56%), fear of an HIV positive result being reported to the government (41%), and fear of a positive HIV test result (36%). Home-based HIV self-testing is an alternative approach for increasing the coverage of HIV testing among Chinese MSM. CBO-based HIV testing is a potential alternative, but further studies are needed to evaluate its feasibility.

  2. Evaluation of Alternative Altitude Scaling Methods for Thermal Ice Protection System in NASA Icing Research Tunnel

    NASA Technical Reports Server (NTRS)

    Lee, Sam; Addy, Harold E. Jr.; Broeren, Andy P.; Orchard, David M.

    2017-01-01

    A test was conducted at NASA Icing Research Tunnel to evaluate altitude scaling methods for thermal ice protection system. Two new scaling methods based on Weber number were compared against a method based on Reynolds number. The results generally agreed with the previous set of tests conducted in NRCC Altitude Icing Wind Tunnel where the three methods of scaling were also tested and compared along with reference (altitude) icing conditions. In those tests, the Weber number-based scaling methods yielded results much closer to those observed at the reference icing conditions than the Reynolds number-based icing conditions. The test in the NASA IRT used a much larger, asymmetric airfoil with an ice protection system that more closely resembled designs used in commercial aircraft. Following the trends observed during the AIWT tests, the Weber number based scaling methods resulted in smaller runback ice than the Reynolds number based scaling, and the ice formed farther upstream. The results show that the new Weber number based scaling methods, particularly the Weber number with water loading scaling, continue to show promise for ice protection system development and evaluation in atmospheric icing tunnels.

  3. Automated Low-Cost Smartphone-Based Lateral Flow Saliva Test Reader for Drugs-of-Abuse Detection

    PubMed Central

    Carrio, Adrian; Sampedro, Carlos; Sanchez-Lopez, Jose Luis; Pimienta, Miguel; Campoy, Pascual

    2015-01-01

    Lateral flow assay tests are nowadays becoming powerful, low-cost diagnostic tools. Obtaining a result is usually subject to visual interpretation of colored areas on the test by a human operator, introducing subjectivity and the possibility of errors in the extraction of the results. While automated test readers providing a result-consistent solution are widely available, they usually lack portability. In this paper, we present a smartphone-based automated reader for drug-of-abuse lateral flow assay tests, consisting of an inexpensive light box and a smartphone device. Test images captured with the smartphone camera are processed in the device using computer vision and machine learning techniques to perform automatic extraction of the results. A deep validation of the system has been carried out showing the high accuracy of the system. The proposed approach, applicable to any line-based or color-based lateral flow test in the market, effectively reduces the manufacturing costs of the reader and makes it portable and massively available while providing accurate, reliable results. PMID:26610513

  4. Comparing Postsecondary Marketing Student Performance on Computer-Based and Handwritten Essay Tests

    ERIC Educational Resources Information Center

    Truell, Allen D.; Alexander, Melody W.; Davis, Rodney E.

    2004-01-01

    The purpose of this study was to determine if there were differences in postsecondary marketing student performance on essay tests based on test format (i.e., computer-based or handwritten). Specifically, the variables of performance, test completion time, and gender were explored for differences based on essay test format. Results of the study…

  5. Understanding evidence-based diagnosis.

    PubMed

    Kohn, Michael A

    2014-01-01

    The real meaning of the word "diagnosis" is naming the disease that is causing a patient's illness. The cognitive process of assigning this name is a mysterious combination of pattern recognition and the hypothetico-deductive approach that is only remotely related to the mathematical process of using test results to update the probability of a disease. What I refer to as "evidence-based diagnosis" is really evidence-based use of medical tests to guide treatment decisions. Understanding how to use test results to update the probability of disease can help us interpret test results more rationally. Also, evidence-based diagnosis reminds us to consider the costs and risks of testing and the dangers of over-diagnosis and over-treatment, in addition to the costs and risks of missing serious disease.

  6. A Window Into Clinical Next-Generation Sequencing-Based Oncology Testing Practices.

    PubMed

    Nagarajan, Rakesh; Bartley, Angela N; Bridge, Julia A; Jennings, Lawrence J; Kamel-Reid, Suzanne; Kim, Annette; Lazar, Alexander J; Lindeman, Neal I; Moncur, Joel; Rai, Alex J; Routbort, Mark J; Vasalos, Patricia; Merker, Jason D

    2017-12-01

    - Detection of acquired variants in cancer is a paradigm of precision medicine, yet little has been reported about clinical laboratory practices across a broad range of laboratories. - To use College of American Pathologists proficiency testing survey results to report on the results from surveys on next-generation sequencing-based oncology testing practices. - College of American Pathologists proficiency testing survey results from more than 250 laboratories currently performing molecular oncology testing were used to determine laboratory trends in next-generation sequencing-based oncology testing. - These presented data provide key information about the number of laboratories that currently offer or are planning to offer next-generation sequencing-based oncology testing. Furthermore, we present data from 60 laboratories performing next-generation sequencing-based oncology testing regarding specimen requirements and assay characteristics. The findings indicate that most laboratories are performing tumor-only targeted sequencing to detect single-nucleotide variants and small insertions and deletions, using desktop sequencers and predesigned commercial kits. Despite these trends, a diversity of approaches to testing exists. - This information should be useful to further inform a variety of topics, including national discussions involving clinical laboratory quality systems, regulation and oversight of next-generation sequencing-based oncology testing, and precision oncology efforts in a data-driven manner.

  7. The progress test as a diagnostic tool for a new PBL curriculum.

    PubMed

    Al Alwan, I; Al-Moamary, M; Al-Attas, N; Al Kushi, A; AlBanyan, E; Zamakhshary, M; Al Kadri, H M F; Tamim, H; Magzoub, M; Hajeer, A; Schmidt, H

    2011-12-01

    The College of Medicine at King Saud bin Abdulaziz University for Health Sciences (KSAU-HS) is running a PBL-based curriculum. A progress test was used to evaluate components of the basic medical and clinical sciences curriculum. To evaluate the performance of students at different levels of the college of medicine curriculum through USMLE-based test that focused on basic medical and clinical sciences topics. The USMLE-based basic medical and clinical sciences progress test has been conducted since 2007. It covers nine topics, including: anatomy; physiology; histology; epidemiology; biochemistry; behavioral sciences, pathology, pharmacology and immunology/microbiology. Here we analyzed results of three consecutive years of all students in years 1-4. There was a good correlation between progress test results and students' GPA. Progress test results in the clinical topics were better than basic medical sciences. In basic medical sciences, results of pharmacology, biochemistry, behavioral sciences and histology gave lower results than the other disciplines. Results of our progress test proved to be a useful indicator for both basic medical sciences and clinical sciences curriculum. Results are being utilized to help in modifying our curriculum.

  8. Medical students’ attitudes and perspectives regarding novel computer-based practical spot tests compared to traditional practical spot tests

    PubMed Central

    Wijerathne, Buddhika; Rathnayake, Geetha

    2013-01-01

    Background Most universities currently practice traditional practical spot tests to evaluate students. However, traditional methods have several disadvantages. Computer-based examination techniques are becoming more popular among medical educators worldwide. Therefore incorporating the computer interface in practical spot testing is a novel concept that may minimize the shortcomings of traditional methods. Assessing students’ attitudes and perspectives is vital in understanding how students perceive the novel method. Methods One hundred and sixty medical students were randomly allocated to either a computer-based spot test (n=80) or a traditional spot test (n=80). The students rated their attitudes and perspectives regarding the spot test method soon after the test. The results were described comparatively. Results Students had higher positive attitudes towards the computer-based practical spot test compared to the traditional spot test. Their recommendations to introduce the novel practical spot test method for future exams and to other universities were statistically significantly higher. Conclusions The computer-based practical spot test is viewed as more acceptable to students than the traditional spot test. PMID:26451213

  9. A rule-based software test data generator

    NASA Technical Reports Server (NTRS)

    Deason, William H.; Brown, David B.; Chang, Kai-Hsiung; Cross, James H., II

    1991-01-01

    Rule-based software test data generation is proposed as an alternative to either path/predicate analysis or random data generation. A prototype rule-based test data generator for Ada programs is constructed and compared to a random test data generator. Four Ada procedures are used in the comparison. Approximately 2000 rule-based test cases and 100,000 randomly generated test cases are automatically generated and executed. The success of the two methods is compared using standard coverage metrics. Simple statistical tests showing that even the primitive rule-based test data generation prototype is significantly better than random data generation are performed. This result demonstrates that rule-based test data generation is feasible and shows great promise in assisting test engineers, especially when the rule base is developed further.

  10. Investigation of fatigue failure in bituminous base mixes.

    DOT National Transportation Integrated Search

    1980-01-01

    A correlation between the results obtained with the fatigue test and those from the indirect tensile test on two base mixes was attempted in anticipation of the possible use of the latter test to design base mixes for maximum fatigue life. Two base m...

  11. Comparing Science Virtual and Paper-Based Test to Measure Students’ Critical Thinking based on VAK Learning Style Model

    NASA Astrophysics Data System (ADS)

    Rosyidah, T. H.; Firman, H.; Rusyati, L.

    2017-02-01

    This research was comparing virtual and paper-based test to measure students’ critical thinking based on VAK (Visual-Auditory-Kynesthetic) learning style model. Quasi experiment method with one group post-test only design is applied in this research in order to analyze the data. There was 40 eight grade students at one of public junior high school in Bandung becoming the sample in this research. The quantitative data was obtained through 26 questions about living thing and environment sustainability which is constructed based on the eight elements of critical thinking and be provided in the form of virtual and paper-based test. Based on analysis of the result, it is shown that within visual, auditory, and kinesthetic were not significantly difference in virtual and paper-based test. Besides, all result was supported by quistionnaire about students’ respond on virtual test which shows 3.47 in the scale of 4. Means that student showed positive respond in all aspet measured, which are interest, impression, and expectation.

  12. Evaluating the Comparability of Paper- and Computer-Based Science Tests across Sex and SES Subgroups

    ERIC Educational Resources Information Center

    Randall, Jennifer; Sireci, Stephen; Li, Xueming; Kaira, Leah

    2012-01-01

    As access and reliance on technology continue to increase, so does the use of computerized testing for admissions, licensure/certification, and accountability exams. Nonetheless, full computer-based test (CBT) implementation can be difficult due to limited resources. As a result, some testing programs offer both CBT and paper-based test (PBT)…

  13. Documentation and archiving of the Space Shuttle wind tunnel test data base. Volume 2: User's Guide to the Archived Data Base

    NASA Technical Reports Server (NTRS)

    Romere, Paul O.; Brown, Steve Wesley

    1995-01-01

    Development of the Space Shuttle necessitated an extensive wind tunnel test program, with the cooperation of all the major wind tunnels in the United States. The result was approximately 100,000 hours of Space Shuttle wind tunnel testing conducted for aerodynamics, heat transfer, and structural dynamics. The test results were converted into Chrysler DATAMAN computer program format to facilitate use by analysts, a very cost effective method of collecting the wind tunnel test results from many test facilities into one centralized location. This report provides final documentation of the Space Shuttle wind tunnel program. The two-volume set covers the evolution of Space Shuttle aerodynamic configurations and gives wind tunnel test data, titles of wind tunnel data reports, sample data sets, and instructions for accessing the digital data base.

  14. A commercially available immunoglobulin E-based test for food allergy gives inconsistent results in healthy ponies.

    PubMed

    Dupont, S; De Spiegeleer, A; Liu, D J X; Lefère, L; van Doorn, D A; Hesta, M

    2016-01-01

    Commercial immunoglobulin E (IgE)-based tests are available for diagnosis of food allergies and are commonly used in equine practice. However, these tests have been proven unreliable as a screening method in man and other species, but not critically evaluated in equids. Therefore, a commercially available IgE-based test for horses was evaluated. To evaluate the consistency of the results obtained with a commercially available IgE-based test for food allergy diagnosis in ponies (Phase I) and to subject ponies to a provocation trial with the presumed allergens (Phase II). Allergen screening followed by experimental food provocation trials in healthy ponies. Blood samples of 17 healthy Shetland ponies were taken at 2 different time points, sent blinded to a commercial laboratory for screening of common food allergens and the results were evaluated for consistency (Phase I). Ponies that were positive for food allergens were consecutively challenged orally with each allergen separately for 14 days (Phase II). A washout period of one week was applied in ponies with multiple positive results. Clinical parameters and serum amyloid A were monitored during the provocation trial. Only 7/17 ponies were negative on the IgE-based test at the 2 time points, 3 had positive results twice but only one tested positive twice for the same food allergen. No abnormalities were noted during the provocation trials. This study demonstrated that this IgE-based test is not a reliable screening tool for food allergy in healthy equids. © 2015 EVJ Ltd.

  15. Space Launch System Base Heating Test: Environments and Base Flow Physics

    NASA Technical Reports Server (NTRS)

    Mehta, Manish; Knox, Kyle; Seaford, Mark; Dufrene, Aaron

    2016-01-01

    NASA MSFC and CUBRC designed and developed a 2% scale SLS propulsive wind tunnel test program to investigate base flow effects during flight from lift-off to MECO. This type of test program has not been conducted in 40+ years during the NASA Shuttle Program. Dufrene et al paper described the operation, instrumentation type and layout, facility and propulsion performance, test matrix and conditions and some raw results. This paper will focus on the SLS base flow physics and the generation and results of the design environments being used to design the thermal protection system.

  16. Impact of SMS/GPRS Printers in Reducing Time to Early Infant Diagnosis Compared With Routine Result Reporting: A Systematic Review and Meta-Analysis

    PubMed Central

    Markby, Jessica; Boeke, Caroline; Penazzato, Martina; Urick, Brittany; Ghadrshenas, Anisa; Harris, Lindsay; Ford, Nathan; Peter, Trevor

    2017-01-01

    Background: Despite significant gains made toward improving access, early infant diagnosis (EID) testing programs suffer from long test turnaround times that result in substantial loss to follow-up and mortality associated with delays in antiretroviral therapy initiation. These delays in treatment initiation are particularly impactful because of significant HIV-related infant mortality observed by 2–3 months of age. Short message service (SMS) and general packet radio service (GPRS) printers allow test results to be transmitted immediately to health care facilities on completion of testing in the laboratory. Methods: We conducted a systematic review and meta-analysis to assess the benefit of using SMS/GPRS printers to increase the efficiency of EID test result delivery compared with traditional courier paper–based results delivery methods. Results: We identified 11 studies contributing data for over 16,000 patients from East and Southern Africa. The test turnaround time from specimen collection to result received at the health care facility with courier paper–based methods was 68.0 days (n = 6835), whereas the test turnaround time with SMS/GPRS printers was 51.1 days (n = 6711), resulting in a 2.5-week (25%) reduction in the turnaround time. Conclusions: Courier paper–based EID test result delivery methods are estimated to add 2.5 weeks to EID test turnaround times in low resource settings and increase the risk that infants receive test results during or after the early peak of infant mortality. SMS/GPRS result delivery to health care facility printers significantly reduced test turnaround time and may reduce this risk. SMS/GPRS printers should be considered for expedited delivery of EID and other centralized laboratory test results. PMID:28825941

  17. Workarounds and Test Results Follow-up in Electronic Health Record-Based Primary Care.

    PubMed

    Menon, Shailaja; Murphy, Daniel R; Singh, Hardeep; Meyer, Ashley N D; Sittig, Dean F

    2016-01-01

    Electronic health records (EHRs) have potential to facilitate reliable communication and follow-up of test results. However, limitations in EHR functionality remain, leading practitioners to use workarounds while managing test results. Workarounds can lead to patient safety concerns and signify indications as to how to build better EHR systems that meet provider needs. To understand why primary care practitioners (PCPs) use workarounds to manage test results by analyzing data from a previously conducted national cross-sectional survey on test result management. We conducted a secondary data analysis of quantitative and qualitative data from a national survey of PCPs practicing in the Department of Veterans Affairs (VA) and explored the use of workarounds in test results management. We used multivariate logistic regression analysis to examine the association between key sociotechnical factors that could affect test results follow-up (e.g., both technology-related and those unrelated to technology, such as organizational support for patient notification) and workaround use. We conducted a qualitative content analysis of free text survey data to examine reasons for use of workarounds. Of 2554 survey respondents, 1104 (43%) reported using workarounds related to test results management. Of these 1028 (93%) described the type of workaround they were using; 719 (70%) reported paper-based methods, while 230 (22%) used a combination of paper- and computer-based workarounds. Primary care practitioners who self-reported limited administrative support to help them notify patients of test results or described an instance where they personally (or a colleague) missed results, were more likely to use workarounds (p=0.02 and p=0.001, respectively). Qualitative analysis identified three main reasons for workaround use: 1) as a memory aid, 2) for improved efficiency and 3) for facilitating internal and external care coordination. Workarounds to manage EHR-based test results are common, and their use results from unmet provider information management needs. Future EHRs and the respective work systems around them need to evolve to meet these needs.

  18. Accounting for Proof Test Data in a Reliability Based Design Optimization Framework

    NASA Technical Reports Server (NTRS)

    Ventor, Gerharad; Scotti, Stephen J.

    2012-01-01

    This paper investigates the use of proof (or acceptance) test data during the reliability based design optimization of structural components. It is assumed that every component will be proof tested and that the component will only enter into service if it passes the proof test. The goal is to reduce the component weight, while maintaining high reliability, by exploiting the proof test results during the design process. The proposed procedure results in the simultaneous design of the structural component and the proof test itself and provides the designer with direct control over the probability of failing the proof test. The procedure is illustrated using two analytical example problems and the results indicate that significant weight savings are possible when exploiting the proof test results during the design process.

  19. Inexpensive electrolysis of batik waste water: Project-based learning (PjBL) in MA Salafiyah Simbang Kulon Pekalongan, Indonesia

    NASA Astrophysics Data System (ADS)

    Firmansyah, R. Arizal; Rohmatina, Ita

    2017-12-01

    Majority of people in Simbang kulon Indonesia almost every citizen who batik artisans, by utilizing river water to wash batik, as well as a place to dispose of waste. As a result, the river is polluted. However, there are no steps to educate young generation especially students to care about the environment. Therefore, project-based learning is appropriate approach. This research was intended to provide a description of the study of project-based chemistry on redox reaction material and its application for the waste treatment of class X MA Salafiyah Simbang Kulon Pekalongan. The implementation of project-based chemistry study of redox reaction material and its application on batik waste treatment in class X MA Salafiyah Simbang Kulon Pekalongan can be seen from several aspects, such as: (1) planning stage: includes preparation of learning planning activities such as RPP preparation of LKS etc, (2) Implementation stage: this stage consists of classroom discussion, and batik waste treatment project (3) evaluation stage. This evaluation was done by the researcher on the results of project-based learning to measure the level of effectiveness of learning with the achievement of students' competencies in terms of cognitive, that is by doing post-test and interview. The end result was to compare the results of the pre-test of learners who achieve the value of KKM with the results of post-test learners who reached the KKM value of 6.8. The results showed that: the effectiveness level of learning chemistry-based projects redox reaction material and its application on the batik waste treatment of class X MA Salafiyah Simbang Kulon Pekalongan was very high, this can be seen from the comparison of the percentage of school KKM achievement between the value of pre-test results with value of post-test result was difference of pre-test result 8,33% with result of post-test 91,66%, so difference was 81,26%. These results were then reinforced by the results of the researcher's interviews of chemistry subject teachers and students who have followed project-based learning. Based on the results of the interviews, interviewees stated that the project-based learning was effective and interesting. Thus, the study of the project-based chemistry of redox reaction material and its application in batik waste treatment can be used as one of effective alternative learning, so as to create more qualified learners, have high creativity and have a high awareness to their environment.

  20. Enhancing a Computer-Based Testing Environment with Optimum Item Response Time

    ERIC Educational Resources Information Center

    Delen, Erhan

    2015-01-01

    As technology has become more advanced and accessible in instructional settings, there has been an upward trend in computer-based testing in the last decades. The present experimental study examines students' behaviors during computer-based testing in two different conditions and explores how these conditions affect the test results. Results…

  1. Integrated vehicle-based safety systems heavy truck field operational test, methodology and results report.

    DOT National Transportation Integrated Search

    2010-12-01

    "This document presents the methodology and results from the heavy-truck field operational test conducted as part of the Integrated Vehicle-Based Safety Systems program. These findings are the result of analyses performed by the University of Michiga...

  2. Integrated vehicle-based safety systems light-vehicle field operational test, methodology and results report.

    DOT National Transportation Integrated Search

    2010-12-01

    "This document presents the methodology and results from the light-vehicle field operational test conducted as part of the Integrated Vehicle-Based Safety Systems program. These findings are the result of analyses performed by the University of Michi...

  3. Development, evaluation and application of performance-based brake testing technologies field test : executive summary

    DOT National Transportation Integrated Search

    1999-09-01

    This report presents the results of the field test portion of the Development, Evaluation, and Application of Performance-Based Brake Testing Technologies sponsored by the Federal Highway Administrations (FHWA) Office of Motor Carriers.

  4. Comparison of Fault Detection Algorithms for Real-time Diagnosis in Large-Scale System. Appendix E

    NASA Technical Reports Server (NTRS)

    Kirubarajan, Thiagalingam; Malepati, Venkat; Deb, Somnath; Ying, Jie

    2001-01-01

    In this paper, we present a review of different real-time capable algorithms to detect and isolate component failures in large-scale systems in the presence of inaccurate test results. A sequence of imperfect test results (as a row vector of I's and O's) are available to the algorithms. In this case, the problem is to recover the uncorrupted test result vector and match it to one of the rows in the test dictionary, which in turn will isolate the faults. In order to recover the uncorrupted test result vector, one needs the accuracy of each test. That is, its detection and false alarm probabilities are required. In this problem, their true values are not known and, therefore, have to be estimated online. Other major aspects in this problem are the large-scale nature and the real-time capability requirement. Test dictionaries of sizes up to 1000 x 1000 are to be handled. That is, results from 1000 tests measuring the state of 1000 components are available. However, at any time, only 10-20% of the test results are available. Then, the objective becomes the real-time fault diagnosis using incomplete and inaccurate test results with online estimation of test accuracies. It should also be noted that the test accuracies can vary with time --- one needs a mechanism to update them after processing each test result vector. Using Qualtech's TEAMS-RT (system simulation and real-time diagnosis tool), we test the performances of 1) TEAMSAT's built-in diagnosis algorithm, 2) Hamming distance based diagnosis, 3) Maximum Likelihood based diagnosis, and 4) HidderMarkov Model based diagnosis.

  5. Effects of different base agents on prediction of skin irritation by sodium lauryl sulfate using patch testing and repeated application test.

    PubMed

    Horita, Kotomi; Horita, Daisuke; Tomita, Hiroyuki; Yasoshima, Mitsue; Yagami, Akiko; Matsunaga, Kayoko

    2017-05-01

    Animal testing for cosmetics was banned in the European Union (EU) in 2013; therefore, human tests to predict and ensure skin safety such as the patch test or usage test are now in demand in Japan as well as in the EU. In order to investigate the effects of different bases on the findings of tests to predict skin irritation, we performed patch testing (PT) and the repeated application test (RAT) using sodium lauryl sulfate (SLS), a well-known irritant, dissolved in 6 different base agents to examine the effects of these bases on skin irritation by SLS. The bases for PT were distilled water, 50% ethanol, 100% ethanol, a gel containing 50% ethanol, white petrolatum, and hydrophilic cream. The concentrations of SLS were 0.2% and 0.5%. Twelve different base combinations were applied to the normal back skin of 19 individuals for 24h. RAT was performed with distilled water, 50% ethanol, 100% ethanol, a gel containing 50% ethanol, white petrolatum, and hydrophilic cream containing SLS at concentrations of 0.2%, 2%, and 5%, being applied to the arms of the same PT subjects. The test preparation of each base was applied at the same site, with 0.2% SLS being used in the first week, 2% SLS in the following week, and 5% SLS in the final week. The results of PT revealed that skin irritation scores varied when SLS at the same concentration was dissolved in a different base. The results of RAT showed that although skin irritation appeared with every base at a concentration of 5%, the positive rate was approximately the same. In conclusion, our results suggest that skin irritation elicited in PT depends on the base, while in RAT, it does not depend on the type of base employed. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Design Of Computer Based Test Using The Unified Modeling Language

    NASA Astrophysics Data System (ADS)

    Tedyyana, Agus; Danuri; Lidyawati

    2017-12-01

    The Admission selection of Politeknik Negeri Bengkalis through interest and talent search (PMDK), Joint Selection of admission test for state Polytechnics (SB-UMPN) and Independent (UM-Polbeng) were conducted by using paper-based Test (PBT). Paper Based Test model has some weaknesses. They are wasting too much paper, the leaking of the questios to the public, and data manipulation of the test result. This reasearch was Aimed to create a Computer-based Test (CBT) models by using Unified Modeling Language (UML) the which consists of Use Case diagrams, Activity diagram and sequence diagrams. During the designing process of the application, it is important to pay attention on the process of giving the password for the test questions before they were shown through encryption and description process. RSA cryptography algorithm was used in this process. Then, the questions shown in the questions banks were randomized by using the Fisher-Yates Shuffle method. The network architecture used in Computer Based test application was a client-server network models and Local Area Network (LAN). The result of the design was the Computer Based Test application for admission to the selection of Politeknik Negeri Bengkalis.

  7. Computer versus paper--does it make any difference in test performance?

    PubMed

    Karay, Yassin; Schauber, Stefan K; Stosch, Christoph; Schüttpelz-Brauns, Katrin

    2015-01-01

    CONSTRUCT: In this study, we examine the differences in test performance between the paper-based and the computer-based version of the Berlin formative Progress Test. In this context it is the first study that allows controlling for students' prior performance. Computer-based tests make possible a more efficient examination procedure for test administration and review. Although university staff will benefit largely from computer-based tests, the question arises if computer-based tests influence students' test performance. A total of 266 German students from the 9th and 10th semester of medicine (comparable with the 4th-year North American medical school schedule) participated in the study (paper = 132, computer = 134). The allocation of the test format was conducted as a randomized matched-pair design in which students were first sorted according to their prior test results. The organizational procedure, the examination conditions, the room, and seating arrangements, as well as the order of questions and answers, were identical in both groups. The sociodemographic variables and pretest scores of both groups were comparable. The test results from the paper and computer versions did not differ. The groups remained within the allotted time, but students using the computer version (particularly the high performers) needed significantly less time to complete the test. In addition, we found significant differences in guessing behavior. Low performers using the computer version guess significantly more than low-performing students in the paper-pencil version. Participants in computer-based tests are not at a disadvantage in terms of their test results. The computer-based test required less processing time. The reason for the longer processing time when using the paper-pencil version might be due to the time needed to write the answer down, controlling for transferring the answer correctly. It is still not known why students using the computer version (particularly low-performing students) guess at a higher rate. Further studies are necessary to understand this finding.

  8. The Comparison of Accuracy Scores on the Paper and Pencil Testing vs. Computer-Based Testing

    ERIC Educational Resources Information Center

    Retnawati, Heri

    2015-01-01

    This study aimed to compare the accuracy of the test scores as results of Test of English Proficiency (TOEP) based on paper and pencil test (PPT) versus computer-based test (CBT). Using the participants' responses to the PPT documented from 2008-2010 and data of CBT TOEP documented in 2013-2014 on the sets of 1A, 2A, and 3A for the Listening and…

  9. Quality assurance in RT-PCR-based BCR/ABL diagnostics--results of an interlaboratory test and a standardization approach.

    PubMed

    Burmeister, T; Maurer, J; Aivado, M; Elmaagacli, A H; Grünebach, F; Held, K R; Hess, G; Hochhaus, A; Höppner, W; Lentes, K U; Lübbert, M; Schäfer, K L; Schafhausen, P; Schmidt, C A; Schüler, F; Seeger, K; Seelig, R; Thiede, C; Viehmann, S; Weber, C; Wilhelm, S; Christmann, A; Clement, J H; Ebener, U; Enczmann, J; Leo, R; Schleuning, M; Schoch, R; Thiel, E

    2000-10-01

    Here we describe the results of an interlaboratory test for RT-PCR-based BCR/ABL analysis. The test was organized in two parts. The number of participating laboratories in the first and second part was 27 and 20, respectively. In the first part samples containing various concentrations of plasmids with the ela2, b2a2 or b3a2 BCR/ABL transcripts were analyzed by PCR. In the second part of the test, cell samples containing various concentrations of BCR/ABL-positive cells were analyzed by RT-PCR. Overall PCR sensitivity was sufficient in approximately 90% of the tests, but a significant number of false positive results were obtained. There were significant differences in sensitivity in the cell-based analysis between the various participants. The results are discussed, and proposals are made regarding the choice of primers, controls, conditions for RNA extraction and reverse transcription.

  10. Wind tunnel test IA300 analysis and results, volume 1

    NASA Technical Reports Server (NTRS)

    Kelley, P. B.; Beaufait, W. B.; Kitchens, L. L.; Pace, J. P.

    1987-01-01

    The analysis and interpretation of wind tunnel pressure data from the Space Shuttle wind tunnel test IA300 are presented. The primary objective of the test was to determine the effects of the Space Shuttle Main Engine (SSME) and the Solid Rocket Booster (SRB) plumes on the integrated vehicle forebody pressure distributions, the elevon hinge moments, and wing loads. The results of this test will be combined with flight test results to form a new data base to be employed in the IVBC-3 airloads analysis. A secondary objective was to obtain solid plume data for correlation with the results of gaseous plume tests. Data from the power level portion was used in conjunction with flight base pressures to evaluate nominal power levels to be used during the investigation of changes in model attitude, eleveon deflection, and nozzle gimbal angle. The plume induced aerodynamic loads were developed for the Space Shuttle bases and forebody areas. A computer code was developed to integrate the pressure data. Using simplified geometrical models of the Space Shuttle elements and components, the pressure data were integrated to develop plume induced force and moments coefficients that can be combined with a power-off data base to develop a power-on data base.

  11. Mathematics Placement Test: Typical Results with Unexpected Outcomes

    ERIC Educational Resources Information Center

    Ingalls, Victoria

    2011-01-01

    Based on the results of a prior case-study analysis of mathematics placement at one university, the mathematics department developed and piloted a mathematics placement test. This article describes the implementation process for a mathematics placement test and further analyzes the test results for the pilot group. As an unexpected result, the…

  12. Workarounds and Test Results Follow-up in Electronic Health Record-Based Primary Care

    PubMed Central

    Menon, Shailaja; Murphy, Daniel R.; Singh, Hardeep; Meyer, Ashley N. D.

    2016-01-01

    Summary Background Electronic health records (EHRs) have potential to facilitate reliable communication and follow-up of test results. However, limitations in EHR functionality remain, leading practitioners to use workarounds while managing test results. Workarounds can lead to patient safety concerns and signify indications as to how to build better EHR systems that meet provider needs. Objective To understand why primary care practitioners (PCPs) use workarounds to manage test results by analyzing data from a previously conducted national cross-sectional survey on test result management. Methods We conducted a secondary data analysis of quantitative and qualitative data from a national survey of PCPs practicing in the Department of Veterans Affairs (VA) and explored the use of workarounds in test results management. We used multivariate logistic regression analysis to examine the association between key sociotechnical factors that could affect test results follow-up (e.g., both technology-related and those unrelated to technology, such as organizational support for patient notification) and workaround use. We conducted a qualitative content analysis of free text survey data to examine reasons for use of workarounds. Results Of 2554 survey respondents, 1104 (43%) reported using workarounds related to test results management. Of these 1028 (93%) described the type of workaround they were using; 719 (70%) reported paper-based methods, while 230 (22%) used a combination of paper- and computer-based workarounds. Primary care practitioners who self-reported limited administrative support to help them notify patients of test results or described an instance where they personally (or a colleague) missed results, were more likely to use workarounds (p=0.02 and p=0.001, respectively). Qualitative analysis identified three main reasons for workaround use: 1) as a memory aid, 2) for improved efficiency and 3) for facilitating internal and external care coordination. Conclusion Workarounds to manage EHR-based test results are common, and their use results from unmet provider information management needs. Future EHRs and the respective work systems around them need to evolve to meet these needs. PMID:27437060

  13. Mated vertical ground vibration test

    NASA Technical Reports Server (NTRS)

    Ivey, E. W.

    1980-01-01

    The Mated Vertical Ground Vibration Test (MVGVT) was considered to provide an experimental base in the form of structural dynamic characteristics for the shuttle vehicle. This data base was used in developing high confidence analytical models for the prediction and design of loads, pogo controls, and flutter criteria under various payloads and operational missions. The MVGVT boost and launch program evolution, test configurations, and their suspensions are described. Test results are compared with predicted analytical results.

  14. Analytical interferences in point-of-care testing glucometers by icodextrin and its metabolites: an overview.

    PubMed

    Floré, Katelijne M J; Delanghe, Joris R

    2009-01-01

    Current point-of-care testing (POCT) glucometers are based on various test principles. Two major method groups dominate the market: glucose oxidase-based systems and glucose dehydrogenase-based systems using pyrroloquinoline quinone (GDH-PQQ) as a cofactor. The GDH-PQQ-based glucometers are replacing the older glucose oxidase-based systems because of their lower sensitivity for oxygen. On the other hand, the GDH-PQQ test method results in falsely elevated blood glucose levels in peritoneal dialysis patients receiving solutions containing icodextrin (e.g., Extraneal; Baxter, Brussels, Belgium). Icodextrin is metabolized in the systemic circulation into different glucose polymers, but mainly maltose, which interferes with the GDH-PQQ-based method. Clinicians should be aware of this analytical interference. The POCT glucometers based on the GDH-PQQ method should preferably not be used in this high-risk population and POCT glucose results inconsistent with clinical suspicion of hypoglycemic coma should be retested with another testing system.

  15. Smartphone-based analysis of biochemical tests for health monitoring support at home.

    PubMed

    Velikova, Marina; Smeets, Ruben L; van Scheltinga, Josien Terwisscha; Lucas, Peter J F; Spaanderman, Marc

    2014-09-01

    In the context of home-based healthcare monitoring systems, it is desirable that the results obtained from biochemical tests - tests of various body fluids such as blood and urine - are objective and automatically generated to reduce the number of man-made errors. The authors present the StripTest reader - an innovative smartphone-based interpreter of biochemical tests based on paper-based strip colour using image processing techniques. The working principles of the reader include image acquisition of the colour strip pads using the camera phone, analysing the images within the phone and comparing them with reference colours provided by the manufacturer to obtain the test result. The detection of kidney damage was used as a scenario to illustrate the application of, and test, the StripTest reader. An extensive evaluation using laboratory and human urine samples demonstrates the reader's accuracy and precision of detection, indicating the successful development of a cheap, mobile and smart reader for home-monitoring of kidney functioning, which can facilitate the early detection of health problems and a timely treatment intervention.

  16. PZT Active Frequency Based Wind Blade Fatigue to Failure Testing Results for Various Blade Designs

    DTIC Science & Technology

    2011-09-01

    PZT Active Frequency Based Wind Blade Fatigue to Failure Testing Results for Various Blade Designs R. J. WERLINK...number. 1. REPORT DATE SEP 2011 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE PZT Active Frequency Based Wind Blade Fatigue ...18 Abstract: This paper summarizes NASA PZT Health Monitoring System results previously reported for 9 meter blade Fatigue loading to failure

  17. Effect of diet on results obtained by use of two commercial test kits for detection of occult blood in feces of dogs.

    PubMed

    Cook, A K; Gilson, S D; Fischer, W D; Kass, P H

    1992-10-01

    To evaluate the effect of diet on results obtained by use of 2 commercial test kits for detection of occult blood in feces, 5 dogs were fed 7 diets in randomized sequence. Dry and canned diets with various principal ingredients were evaluated. Each diet was offered twice over a 24-hour period, followed by a 36-hour nonfeeding period. Fecal specimens were collected twice daily, and tests for occult blood were performed within 12 hours. The dietary origin of fecal specimens was confirmed by use of colored markers fed with each diet, and was correlated with estimates of gastrointestinal tract transit time. A modified guaiac paper test and an o-tolidine tablet test were performed on each specimen. Of 59 specimens, 4 were positive for occult blood, using the o-tolidine tablet test. Three positive results were associated with a mutton-based canned diet, and 1 positive result was associated with a canned beef-based diet. Of 59 specimens, 11 were positive for occult blood, using the modified guaiac paper test. Four positive results were associated with the mutton diet, and 3 positive results were associated with the beef diet. Of the remaining 5 diets, 4 caused 1 positive reaction. Results were inconsistent with the null hypothesis that the distribution of positive occult blood test results is not affected by diet (P < 0.025), and indicate that diet can affect the specificity of peroxidase-based tests for detection of occult blood in canine feces. Diet modification prior to testing is recommended.

  18. Does Medical Students' Preference of Test Format (Computer-based vs. Paper-based) have an Influence on Performance?

    PubMed Central

    2011-01-01

    Background Computer-based examinations (CBE) ensure higher efficiency with respect to producibility and assessment compared to paper-based examinations (PBE). However, students often have objections against CBE and are afraid of getting poorer results in a CBE. The aims of this study were (1) to assess the readiness and the objections of students to a CBE vs. PBE (2) to examine the acceptance and satisfaction with the CBE on a voluntary basis, and (3) to compare the results of the examinations, which were conducted in different formats. Methods Fifth year medical students were introduced to an examination-player and were free to choose their format for the test. The reason behind the choice of the format as well as the satisfaction with the choice was evaluated after the test with a questionnaire. Additionally, the expected and achieved examination results were measured. Results Out of 98 students, 36 voluntarily chose a CBE (37%), 62 students chose a PBE (63%). Both groups did not differ concerning sex, computer-experience, their achieved examination results of the test, and their satisfaction with the chosen format. Reasons for the students' objections against CBE include the possibility for outlines or written notices, a better overview, additional noise from the keyboard or missing habits normally present in a paper based exam. The students with the CBE tended to judge their examination to be more clear and understandable. Moreover, they saw their results to be independent of the format. Conclusions Voluntary computer-based examinations lead to equal test scores compared to a paper-based format. PMID:22026970

  19. Cognitive Effects of Mindfulness Training: Results of a Pilot Study Based on a Theory Driven Approach

    PubMed Central

    Wimmer, Lena; Bellingrath, Silja; von Stockhausen, Lisa

    2016-01-01

    The present paper reports a pilot study which tested cognitive effects of mindfulness practice in a theory-driven approach. Thirty-four fifth graders received either a mindfulness training which was based on the mindfulness-based stress reduction approach (experimental group), a concentration training (active control group), or no treatment (passive control group). Based on the operational definition of mindfulness by Bishop et al. (2004), effects on sustained attention, cognitive flexibility, cognitive inhibition, and data-driven as opposed to schema-based information processing were predicted. These abilities were assessed in a pre-post design by means of a vigilance test, a reversible figures test, the Wisconsin Card Sorting Test, a Stroop test, a visual search task, and a recognition task of prototypical faces. Results suggest that the mindfulness training specifically improved cognitive inhibition and data-driven information processing. PMID:27462287

  20. Cognitive Effects of Mindfulness Training: Results of a Pilot Study Based on a Theory Driven Approach.

    PubMed

    Wimmer, Lena; Bellingrath, Silja; von Stockhausen, Lisa

    2016-01-01

    The present paper reports a pilot study which tested cognitive effects of mindfulness practice in a theory-driven approach. Thirty-four fifth graders received either a mindfulness training which was based on the mindfulness-based stress reduction approach (experimental group), a concentration training (active control group), or no treatment (passive control group). Based on the operational definition of mindfulness by Bishop et al. (2004), effects on sustained attention, cognitive flexibility, cognitive inhibition, and data-driven as opposed to schema-based information processing were predicted. These abilities were assessed in a pre-post design by means of a vigilance test, a reversible figures test, the Wisconsin Card Sorting Test, a Stroop test, a visual search task, and a recognition task of prototypical faces. Results suggest that the mindfulness training specifically improved cognitive inhibition and data-driven information processing.

  1. The I-V Measurement System for Solar Cells Based on MCU

    NASA Astrophysics Data System (ADS)

    Fengxiang, Chen; Yu, Ai; Jiafu, Wang; Lisheng, Wang

    2011-02-01

    In this paper, an I-V measurement system for solar cells based on Single-chip Microcomputer (MCU) is presented. According to the test principles of solar cells, this measurement system mainly comprises of two parts—data collecting, data processing and displaying. The MCU mainly used as to acquire data, then the collecting results is sent to the computer by serial port. The I-V measurement results of our test system are shown in the human-computer interaction interface based on our hardware circuit. By comparing the test results of our I-V tester and the results of other commercial I-V tester, we found errors for most parameters are less than 5%, which shows our I-V test result is reliable. Because the MCU can be applied in many fields, this I-V measurement system offers a simple prototype for portable I-V tester for solar cells.

  2. Computerized Adaptive Performance Evaluation.

    DTIC Science & Technology

    1980-02-01

    based on classical psychological test theory, with the result that the obtained measurements ani statements of achievement or performance have... psychological aspects of the achievement testing environment. Results , C Applications of Item Characteristic Curve Models and Adaptive Testing Strategies ICC...of immediate knowledge of results and adaptive testing on ability test performance (Research Report 76-4). Minneapolis: Department of Psychology

  3. Integrated vehicle-based safety systems field operational test final program report.

    DOT National Transportation Integrated Search

    2011-06-01

    "This document presents results from the light-vehicle and heavy-truck field operational tests performed as part of the Integrated Vehicle-Based Safety Systems (IVBSS) program. The findings are the result of analyses performed by the University of Mi...

  4. Integrated Vehicle-Based Safety Systems Field Operational Test : Final Program Report

    DOT National Transportation Integrated Search

    2011-06-01

    This document presents results from the light-vehicle and heavy-truck field operational tests performed as part of the Integrated Vehicle-Based Safety Systems (IVBSS) program. The findings are the result of analyses performed by the University of Mic...

  5. The comparison between science virtual and paper based test in measuring grade 7 students’ critical thinking

    NASA Astrophysics Data System (ADS)

    Dhitareka, P. H.; Firman, H.; Rusyati, L.

    2018-05-01

    This research is comparing science virtual and paper-based test in measuring grade 7 students’ critical thinking based on Multiple Intelligences and gender. Quasi experimental method with within-subjects design is conducted in this research in order to obtain the data. The population of this research was all seventh grade students in ten classes of one public secondary school in Bandung. There were 71 students within two classes taken randomly became the sample in this research. The data are obtained through 28 questions with a topic of living things and environmental sustainability constructed based on eight critical thinking elements proposed by Inch then the questions provided in science virtual and paper-based test. The data was analysed by using paired-samples t test when the data are parametric and Wilcoxon signed ranks test when the data are non-parametric. In general comparison, the p-value of the comparison between science virtual and paper-based tests’ score is 0.506, indicated that there are no significance difference between science virtual and paper-based test based on the tests’ score. The results are furthermore supported by the students’ attitude result which is 3.15 from the scale from 1 to 4, indicated that they have positive attitudes towards Science Virtual Test.

  6. Evaluating the efficacy of a chemistry video game

    NASA Astrophysics Data System (ADS)

    Shapiro, Marina

    A quasi-experimental design pre-test/post-test intervention study utilizing a within group analysis was conducted with 45 undergraduate college chemistry students that investigated the effect of implementing a game-based learning environment into an undergraduate college chemistry course in order to learn if serious educational games (SEGs) can be used to achieve knowledge gains of complex chemistry concepts and to achieve increase in students' positive attitude toward chemistry. To evaluate if students learn chemistry concepts by participating in a chemistry game-based learning environment, a one-way repeated measures analysis of variance (ANOVA) was conducted across three time points (pre-test, post-test, delayed post-test which were chemistry content exams). Results showed that there was an increase in exam scores over time. The results of the ANOVA indicated a statistically significant time effect. To evaluate if students' attitude towards chemistry increased as a result of participating in a chemistry game-based learning environment a paired samples t-test was conducted using a chemistry attitudinal survey by Mahdi (2014) as the pre- and post-test. Results of the paired-samples t-test indicated that there was no significant difference in pre-attitudinal scores and post-attitudinal scores.

  7. A Test of Concept Study of At-Home, Self-Administered HIV Testing With Web-Based Peer Counseling Via Video Chat for Men Who Have Sex With Men

    PubMed Central

    Eaton, Lisa A; Siembida, Elizabeth J; Driffin, Daniel D; Baldwin, Robert

    2016-01-01

    Background Men who have sex with men (MSM), particularly MSM who identify as African-American or Black (BMSM), are the sociodemographic group that is most heavily burdened by the human immunodeficiency virus (HIV) epidemic in the United States. To meet national HIV testing goals, there must be a greater emphasis on novel ways to promote and deliver HIV testing to MSM. Obstacles to standard, clinic-based HIV testing include concerns about stigmatization or recognition at in-person testing sites, as well as the inability to access a testing site due to logistical barriers. Objective This study examined the feasibility of self-administered, at-home HIV testing with Web-based peer counseling to MSM by using an interactive video chatting method. The aims of this study were to (1) determine whether individuals would participate in at-home HIV testing with video chat–based test counseling with a peer counselor, (2) address logistical barriers to HIV testing that individuals who report risk for HIV transmission may experience, and (3) reduce anticipated HIV stigma, a primary psychosocial barrier to HIV testing.   Methods In response to the gap in HIV testing, a pilot study was developed and implemented via mailed, at-home HIV test kits, accompanied by HIV counseling with a peer counselor via video chat. A total of 20 MSM were enrolled in this test of concept study, 80% of whom identified as BMSM. Results All participants reported that at-home HIV testing with a peer counseling via video chat was a satisfying experience. The majority of participants (13/18, 72%) said they would prefer for their next HIV testing and counseling experience to be at home with Web-based video chat peer counseling, as opposed to testing in an office or clinic setting. Participants were less likely to report logistical and emotional barriers to HIV testing at the 6-week and 3-month follow-ups. Conclusions The results of this study suggest that self-administered HIV testing with Web-based peer counseling is feasible and that MSM find it to be a satisfactory means by which they can access their test results. This study can serve as a general guideline for future, larger-scale studies of Web-based HIV test counseling for MSM. PMID:27974287

  8. Additional corpus biopsy enhances the detection of Helicobacter pylori infection in a background of gastritis with atrophy

    PubMed Central

    2012-01-01

    Background The best sites for biopsy-based tests to evaluate H. pylori infection in gastritis with atrophy are not well known. This study aimed to evaluate the site and sensitivity of biopsy-based tests in terms of degree of gastritis with atrophy. Methods One hundred and sixty-four (164) uninvestigated dyspepsia patients were enrolled. Biopsy-based tests (i.e., culture, histology Giemsa stain and rapid urease test) and non-invasive tests (anti-H. pylori IgG) were performed. The gold standard of H. pylori infection was defined according to previous criteria. The sensitivity, specificity, positive predictive rate and negative predictive rate of biopsy-based tests at the gastric antrum and body were calculated in terms of degree of gastritis with atrophy. Results The prevalence rate of H. pylori infection in the 164 patients was 63.4%. Gastritis with atrophy was significantly higher at the antrum than at the body (76% vs. 31%; p<0.001). The sensitivity of biopsy-based test decreased when the degree of gastritis with atrophy increased regardless of biopsy site (for normal, mild, moderate, and severe gastritis with atrophy, the sensitivity of histology Giemsa stain was 100%, 100%, 88%, and 66%, respectively, and 100%, 97%, 91%, and 66%, respectively, for rapid urease test). In moderate to severe antrum or body gastritis with atrophy, additional corpus biopsy resulted in increased sensitivity to 16.67% compare to single antrum biopsy. Conclusions In moderate to severe gastritis with atrophy, biopsy-based test should include the corpus for avoiding false negative results. PMID:23272897

  9. Blood-based detection of RAS mutations to guide anti-EGFR therapy in colorectal cancer patients: concordance of results from circulating tumor DNA and tissue-based RAS testing.

    PubMed

    Schmiegel, Wolff; Scott, Rodney J; Dooley, Susan; Lewis, Wendy; Meldrum, Cliff J; Pockney, Peter; Draganic, Brian; Smith, Steve; Hewitt, Chelsee; Philimore, Hazel; Lucas, Amanda; Shi, Elva; Namdarian, Kateh; Chan, Timmy; Acosta, Danilo; Ping-Chang, Su; Tannapfel, Andrea; Reinacher-Schick, Anke; Uhl, Waldemar; Teschendorf, Christian; Wolters, Heiner; Stern, Josef; Viebahn, Richard; Friess, Helmut; Janssen, Klaus-Peter; Nitsche, Ulrich; Slotta-Huspenina, Julia; Pohl, Michael; Vangala, Deepak; Baraniskin, Alexander; Dockhorn-Dworniczak, Barbara; Hegewisch-Becker, Susanne; Ronga, Philippe; Edelstein, Daniel L; Jones, Frederick S; Hahn, Stephan; Fox, Stephen B

    2017-02-01

    An accurate blood-based RAS mutation assay to determine eligibility of metastatic colorectal cancer (mCRC) patients for anti-EGFR therapy would benefit clinical practice by better informing decisions to administer treatment independent of tissue availability. The objective of this study was to determine the level of concordance between plasma and tissue RAS mutation status in patients with mCRC to gauge whether blood-based RAS mutation testing is a viable alternative to standard-of-care RAS tumor testing. RAS testing was performed on plasma samples from newly diagnosed metastatic patients, or from recurrent mCRC patients using the highly sensitive digital PCR technology, BEAMing (beads, emulsions, amplification, and magnetics), and compared with DNA sequencing data of respective FFPE (formalin-fixed paraffin-embedded) tumor samples. Discordant tissue RAS results were re-examined by BEAMing, if possible. The prevalence of RAS mutations detected in plasma (51%) vs. tumor (53%) was similar, in accord with the known prevalence of RAS mutations observed in mCRC patient populations. The positive agreement between plasma and tumor RAS results was 90.4% (47/52), the negative agreement was 93.5% (43/46), and the overall agreement (concordance) was 91.8% (90/98). The high concordance of plasma and tissue results demonstrates that blood-based RAS mutation testing is a viable alternative to tissue-based RAS testing. © 2016 The Authors. Published by FEBS Press and John Wiley & Sons Ltd.

  10. Development of HAN-based Liquid Propellant Thruster

    NASA Astrophysics Data System (ADS)

    Hisatsune, K.; Izumi, J.; Tsutaya, H.; Furukawa, K.

    2004-10-01

    Many of propellants that are applied to the conventional spacecraft propulsion system are toxic propellants. Because of its toxicity, considering the environmental pollution or safety on handling, it will be necessary to apply the "green" propellant to the spacecraft propulsion system. The purpose of this study is to apply HAN based liquid propellant (LP1846) to mono propellant thruster. Compared to the hydrazine that is used in conventional mono propellant thruster, HAN based propellant is not only lower toxic but also can obtain higher specific impulse. Moreover, HAN based propellant can be decomposed by the catalyst. It means there are the possibility of applying to the mono propellant thruster that can leads to the high reliability of the propulsion system.[1],[2] However, there are two technical subjects, to apply HAN based propellant to the mono propellant thruster. One is the high combustion temperature. The catalyst will be damaged under high temperature condition. The other is the low catalytic activity. It is the serious problem on application of HAN based propellant to the mono propellant thruster that is used for attitude control of spacecraft. To improve the catalytic activity of HAN based propellant, it is necessary to screen the best catalyst for HAN based propellant. The adsorption analysis is conducted by Monte Carlo Simulation to screen the catalyst metal for HAN and TEAN. The result of analysis shows the Iridium is the best catalyst metal for HAN and TEAN. Iridium is the catalyst metal that is used at conventional mono propellant thruster catalyst Shell405. Then, to confirm the result of analysis, the reaction test about catalyst is conducted. The result of this test is the same as the result of adsorption analysis. That means the adsorption analysis is effective in screening the catalyst metal. At the evaluating test, the various types of carrier of catalyst are also compared to Shell 405 to improve catalytic activity. The test result shows the inorganic porous media is superior to Shell405 in catalytic activity. Next, the catalyst life with HAN based propellant (LP1846) is evaluated. The Shell405 and inorganic porous media catalyst are compared at the life test. The test result shows the inorganic porous media catalyst is superior to Shell405 in catalyst life. In this paper, the detail of the result of adsorption analysis and evaluating test are reported.

  11. Meta-analysis: accuracy of rapid tests for malaria in travelers returning from endemic areas.

    PubMed

    Marx, Arthur; Pewsner, Daniel; Egger, Matthias; Nüesch, Reto; Bucher, Heiner C; Genton, Blaise; Hatz, Christoph; Jüni, Peter

    2005-05-17

    Microscopic diagnosis of malaria is unreliable outside specialized centers. Rapid tests have become available in recent years, but their accuracy has not been assessed systematically. To determine the accuracy of rapid diagnostic tests for ruling out malaria in nonimmune travelers returning from malaria-endemic areas. The authors searched MEDLINE, EMBASE, CAB Health, and CINAHL (1988 to September 2004); hand-searched conference proceedings; checked reference lists; and contacted experts and manufacturers. Diagnostic accuracy studies in nonimmune individuals with suspected malaria were included if they compared rapid tests with expert microscopic examination or polymerase chain reaction tests. Data on study and patient characteristics and results were extracted in duplicate. The main outcome was the likelihood ratio for a negative test result (negative likelihood ratio) for Plasmodium falciparum malaria. Likelihood ratios were combined by using random-effects meta-analysis, stratified by the antigen targeted (histidine-rich protein-2 [HRP-2] or parasite lactate dehydrogenase [LDH]) and by test generation. Nomograms of post-test probabilities were constructed. The authors included 21 studies and 5747 individuals. For P. falciparum, HRP-2-based tests were more accurate than parasite LDH-based tests: Negative likelihood ratios were 0.08 and 0.13, respectively (P = 0.019 for difference). Three-band HRP-2 tests had similar negative likelihood ratios but higher positive likelihood ratios compared with 2-band tests (34.7 vs. 98.5; P = 0.003). For P. vivax, negative likelihood ratios tended to be closer to 1.0 for HRP-2-based tests than for parasite LDH-based tests (0.24 vs. 0.13; P = 0.22), but analyses were based on a few heterogeneous studies. Negative likelihood ratios for the diagnosis of P. malariae or P. ovale were close to 1.0 for both types of tests. In febrile travelers returning from sub-Saharan Africa, the typical probability of P. falciparum malaria is estimated at 1.1% (95% CI, 0.6% to 1.9%) after a negative 3-band HRP-2 test result and 97% (CI, 92% to 99%) after a positive test result. Few studies evaluated 3-band HRP-2 tests. The evidence is also limited for species other than P. falciparum because of the few available studies and their more heterogeneous results. Further studies are needed to determine whether the use of rapid diagnostic tests improves outcomes in returning travelers with suspected malaria. Rapid malaria tests may be a useful diagnostic adjunct to microscopy in centers without major expertise in tropical medicine. Initial decisions on treatment initiation and choice of antimalarial drugs can be based on travel history and post-test probabilities after rapid testing. Expert microscopy is still required for species identification and confirmation.

  12. DarT: The embryo test with the Zebrafish Danio rerio--a general model in ecotoxicology and toxicology.

    PubMed

    Nagel, Roland

    2002-01-01

    The acute fish test is an animal test whose ecotoxicological relevance is worthy of discussion. The primary aim of protection in ecotoxicology is the population and not the individual. Furthermore the concentration of pollutants in the environment is normally not in the lethal range. Therefore the acute fish test covers solely the situation after chemical spills. Nevertheless, acute fish toxicity data still belong to the base set used for the assessment of chemicals. The embryo test with the zebrafish Danio rerio (DarT) is recommended as a substitute for the acute fish test. For validation an international laboratory comparison test was carried out. A summary of the results is presented in this paper. Based on the promising results of testing chemicals and waste water the test design was validated by the DIN-working group "7.6 Fischei-Test". A normed test guideline for testing waste water with fish is available. The test duration is short (48 h) and within the test different toxicological endpoints can be examined. Endpoints from the embryo test are suitable for QSAR-studies. Besides the use in ecotoxicology the introduction as a toxicological model was investigated. Disturbance of pigmentation and effects on the frequency of heart-beat were examined. A further important application is testing of teratogenic chemicals. Based on the results DarT could be a screening test within preclinical studies.

  13. Wald Sequential Probability Ratio Test for Space Object Conjunction Assessment

    NASA Technical Reports Server (NTRS)

    Carpenter, James R.; Markley, F Landis

    2014-01-01

    This paper shows how satellite owner/operators may use sequential estimates of collision probability, along with a prior assessment of the base risk of collision, in a compound hypothesis ratio test to inform decisions concerning collision risk mitigation maneuvers. The compound hypothesis test reduces to a simple probability ratio test, which appears to be a novel result. The test satisfies tolerances related to targeted false alarm and missed detection rates. This result is independent of the method one uses to compute the probability density that one integrates to compute collision probability. A well-established test case from the literature shows that this test yields acceptable results within the constraints of a typical operational conjunction assessment decision timeline. Another example illustrates the use of the test in a practical conjunction assessment scenario based on operations of the International Space Station.

  14. Alternative methods of flexible base compaction acceptance.

    DOT National Transportation Integrated Search

    2012-11-01

    "This report presents the results from the second year of research work investigating issues with flexible base acceptance testing within the Texas Department of Transportation. This second year of work focused on shadow testing non-density-based acc...

  15. Comparing In-Class and Out-of-Class Computer-Based Tests to Traditional Paper-and-Pencil Tests in Introductory Psychology Courses

    ERIC Educational Resources Information Center

    Frein, Scott T.

    2011-01-01

    This article describes three experiments comparing paper-and-pencil tests (PPTs) to computer-based tests (CBTs) in terms of test method preferences and student performance. In Experiment 1, students took tests using three methods: PPT in class, CBT in class, and CBT at the time and place of their choosing. Results indicate that test method did not…

  16. Bioassays and field immersion tests: a comparison of the antifouling activity of copper-free poly(methacrylic)-based coatings containing tertiary amines and ammonium salt groups.

    PubMed

    Bressy, C; Hellio, C; Marechal, J P; Tanguy, B; Margaillan, A

    2010-10-01

    This paper focuses on the activity spectrum of three dimethylalkyl tertiary amines as potential active molecules and the corresponding ammonium salt-based antifouling (AF) paints. Bioassays (using marine bacteria, microalgae and barnacles) and field tests were combined to assess the AF activity of coatings. Bioassay results demonstrated that the ammonium salt-based paints did not inhibit the growth of microorganisms (except the dimethyldodecylammonium-based coatings) and that the tertiary amines were potent towards bacteria, diatoms, and barnacle larvae at non-toxic concentrations (therapeutic ratio, LC50/EC50, <1). The results from field tests indicated that the ammonium salt-based coatings inhibited the settlement of macrofouling and the dimethylhexadecylammonium-based coatings provided protection against slime in comparison with PVC blank panels. Thus, results from laboratory assays did not fully concur with the AF activity of the paints in the field trial.

  17. Does medical students' preference of test format (computer-based vs. paper-based) have an influence on performance?

    PubMed

    Hochlehnert, Achim; Brass, Konstantin; Moeltner, Andreas; Juenger, Jana

    2011-10-25

    Computer-based examinations (CBE) ensure higher efficiency with respect to producibility and assessment compared to paper-based examinations (PBE). However, students often have objections against CBE and are afraid of getting poorer results in a CBE.The aims of this study were (1) to assess the readiness and the objections of students to a CBE vs. PBE (2) to examine the acceptance and satisfaction with the CBE on a voluntary basis, and (3) to compare the results of the examinations, which were conducted in different formats. Fifth year medical students were introduced to an examination-player and were free to choose their format for the test. The reason behind the choice of the format as well as the satisfaction with the choice was evaluated after the test with a questionnaire. Additionally, the expected and achieved examination results were measured. Out of 98 students, 36 voluntarily chose a CBE (37%), 62 students chose a PBE (63%). Both groups did not differ concerning sex, computer-experience, their achieved examination results of the test, and their satisfaction with the chosen format. Reasons for the students' objections against CBE include the possibility for outlines or written notices, a better overview, additional noise from the keyboard or missing habits normally present in a paper based exam. The students with the CBE tended to judge their examination to be more clear and understandable. Moreover, they saw their results to be independent of the format. Voluntary computer-based examinations lead to equal test scores compared to a paper-based format.

  18. Tests of an ATCRBS Based Trilateration Sensor at Logan International Airport

    DOT National Transportation Integrated Search

    1979-11-01

    Field test results of accuracy and coverage for an ATCRBS based surface trilateration sensor at Logan International Airport are described. This sensor was previously tested at NAFEC for feasibility and because of a lack of sufficient aircraft traffic...

  19. A Cancer Gene Selection Algorithm Based on the K-S Test and CFS.

    PubMed

    Su, Qiang; Wang, Yina; Jiang, Xiaobing; Chen, Fuxue; Lu, Wen-Cong

    2017-01-01

    To address the challenging problem of selecting distinguished genes from cancer gene expression datasets, this paper presents a gene subset selection algorithm based on the Kolmogorov-Smirnov (K-S) test and correlation-based feature selection (CFS) principles. The algorithm selects distinguished genes first using the K-S test, and then, it uses CFS to select genes from those selected by the K-S test. We adopted support vector machines (SVM) as the classification tool and used the criteria of accuracy to evaluate the performance of the classifiers on the selected gene subsets. This approach compared the proposed gene subset selection algorithm with the K-S test, CFS, minimum-redundancy maximum-relevancy (mRMR), and ReliefF algorithms. The average experimental results of the aforementioned gene selection algorithms for 5 gene expression datasets demonstrate that, based on accuracy, the performance of the new K-S and CFS-based algorithm is better than those of the K-S test, CFS, mRMR, and ReliefF algorithms. The experimental results show that the K-S test-CFS gene selection algorithm is a very effective and promising approach compared to the K-S test, CFS, mRMR, and ReliefF algorithms.

  20. A new biological test of water toxicity-yeast Saccharomyces cerevisiae conductometric test.

    PubMed

    Dolezalova, Jaroslava; Rumlova, Lubomira

    2014-11-01

    This new biological test of water toxicity is based on monitoring of specific conductivity changes of yeast Saccharomyces cerevisiae suspension as a result of yeast fermentation activity inhibition in toxic conditions. The test was verified on ten substances with various mechanisms of toxic effect and the results were compared with two standard toxicity tests based on Daphnia magna mobility inhibition (EN ISO 6341) and Vibrio fischeri bioluminescence inhibition (EN ISO 11348-2) and with the results of the S. cerevisiae lethal test (Rumlova and Dolezalova, 2012). The new biological test - S. cerevisiae conductometric test - is an express method developed primarily for field conditions. It is applicable in case of need of immediate information about water toxicity. Fast completion is an advantage of this test (time necessary for test completion is about 60min), the test is simple and the test organism - dried instant yeast - belongs among its biggest advantages because of its long-term storage life and broad availability. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Wind-Tunnel Investigations of Blunt-Body Drag Reduction Using Forebody Surface Roughness

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Sprague, Stephanie; Naughton, Jonathan W.; Curry, Robert E. (Technical Monitor)

    2001-01-01

    This paper presents results of wind-tunnel tests that demonstrate a novel drag reduction technique for blunt-based vehicles. For these tests, the forebody roughness of a blunt-based model was modified using micomachined surface overlays. As forebody roughness increases, boundary layer at the model aft thickens and reduces the shearing effect of external flow on the separated flow behind the base region, resulting in reduced base drag. For vehicle configurations with large base drag, existing data predict that a small increment in forebody friction drag will result in a relatively large decrease in base drag. If the added increment in forebody skin drag is optimized with respect to base drag, reducing the total drag of the configuration is possible. The wind-tunnel tests results conclusively demonstrate the existence of a forebody dragbase drag optimal point. The data demonstrate that the base drag coefficient corresponding to the drag minimum lies between 0.225 and 0.275, referenced to the base area. Most importantly, the data show a drag reduction of approximately 15% when the drag optimum is reached. When this drag reduction is scaled to the X-33 base area, drag savings approaching 45,000 N (10,000 lbf) can be realized.

  2. Tests for detecting overdispersion in models with measurement error in covariates.

    PubMed

    Yang, Yingsi; Wong, Man Yu

    2015-11-30

    Measurement error in covariates can affect the accuracy in count data modeling and analysis. In overdispersion identification, the true mean-variance relationship can be obscured under the influence of measurement error in covariates. In this paper, we propose three tests for detecting overdispersion when covariates are measured with error: a modified score test and two score tests based on the proposed approximate likelihood and quasi-likelihood, respectively. The proposed approximate likelihood is derived under the classical measurement error model, and the resulting approximate maximum likelihood estimator is shown to have superior efficiency. Simulation results also show that the score test based on approximate likelihood outperforms the test based on quasi-likelihood and other alternatives in terms of empirical power. By analyzing a real dataset containing the health-related quality-of-life measurements of a particular group of patients, we demonstrate the importance of the proposed methods by showing that the analyses with and without measurement error correction yield significantly different results. Copyright © 2015 John Wiley & Sons, Ltd.

  3. Accuracy and Cost-Effectiveness of Cervical Cancer Screening by High-Risk HPV DNA Testing of Self-Collected Vaginal Samples

    PubMed Central

    Balasubramanian, Akhila; Kulasingam, Shalini L.; Baer, Atar; Hughes, James P.; Myers, Evan R.; Mao, Constance; Kiviat, Nancy B.; Koutsky, Laura A.

    2010-01-01

    Objective Estimate the accuracy and cost-effectiveness of cervical cancer screening strategies based on high-risk HPV DNA testing of self-collected vaginal samples. Materials and Methods A subset of 1,665 women (18-50 years of age) participating in a cervical cancer screening study were screened by liquid-based cytology and by high-risk HPV DNA testing of both self-collected vaginal swab samples and clinician-collected cervical samples. Women with positive/abnormal screening test results and a subset of women with negative screening test results were triaged to colposcopy. Based on individual and combined test results, five screening strategies were defined. Estimates of sensitivity and specificity for cervical intraepithelial neoplasia grade 2 or worse were calculated and a Markov model was used to estimate the incremental cost-effectiveness ratios (ICERs) for each strategy. Results Compared to cytology-based screening, high-risk HPV DNA testing of self-collected vaginal samples was more sensitive (68%, 95%CI=58%-78% versus 85%, 95%CI=76%-94%) but less specific (89%, 95%CI=86%-91% versus 73%, 95%CI=67%-79%). A strategy of high-risk HPV DNA testing of self-collected vaginal samples followed by cytology triage of HPV positive women, was comparably sensitive (75%, 95%CI=64%-86%) and specific (88%, 95%CI=85%-92%) to cytology-based screening. In-home self-collection for high-risk HPV DNA detection followed by in-clinic cytology triage had a slightly lower lifetime cost and a slightly higher quality-adjusted life expectancy than did cytology-based screening (ICER of triennial screening compared to no screening was $9,871/QALY and $12,878/QALY, respectively). Conclusions Triennial screening by high-risk HPV DNA testing of in-home, self-collected vaginal samples followed by in-clinic cytology triage was cost-effective. PMID:20592553

  4. Documentation and archiving of the Space Shuttle wind tunnel test data base. Volume 1: Background and description

    NASA Technical Reports Server (NTRS)

    Romere, Paul O.; Brown, Steve Wesley

    1995-01-01

    Development of the space shuttle necessitated an extensive wind tunnel test program, with the cooperation of all the major wind tunnels in the United States. The result was approximately 100,000 hours of space shuttle wind tunnel testing conducted for aerodynamics, heat transfer, and structural dynamics. The test results were converted into Chrysler DATAMAN computer program format to facilitate use by analysts, a very cost effective method of collecting the wind tunnel test results from many test facilities into one centralized location. This report provides final documentation of the space shuttle wind tunnel program. The two-volume set covers evolution of space shuttle aerodynamic configurations and gives wind tunnel test data, titles of wind tunnel data reports, sample data sets, and instructions for accessing the digital data base.

  5. Experimental evaluation of high performance base course and road base asphalt concrete with electric arc furnace steel slags.

    PubMed

    Pasetto, Marco; Baldo, Nicola

    2010-09-15

    The paper presents the results of a laboratory study aimed at verifying the use of two types of electric arc furnace (EAF) steel slags as substitutes for natural aggregates, in the composition of base course and road base asphalt concrete (BBAC) for flexible pavements. The trial was composed of a preliminary study of the chemical, physical, mechanical and leaching properties of the EAF steel slags, followed by the mix design and performance characterization of the bituminous mixes, through gyratory compaction tests, permanent deformation tests, stiffness modulus tests at various temperatures, fatigue tests and indirect tensile strength tests. All the mixtures with EAF slags presented better mechanical characteristics than those of the corresponding asphalts with natural aggregate and satisfied the requisites for acceptance in the Italian road sector technical standards, thus resulting as suitable for use in road construction. Copyright 2010 Elsevier B.V. All rights reserved.

  6. Annealing Would Improve beta" - Alumina Solid Electrolyte

    NASA Technical Reports Server (NTRS)

    Williams, Roger; Homer, Margie; Ryan, Margaret; Cortez, Roger; Shields, Virgil; Kisor, Adam

    2003-01-01

    A pre-operational annealing process is under investigation as a potential means of preventing a sudden reduction of ionic conductivity in a Beta"-alumina solid electrolyte (BASE) during use. On the basis of tests, the sudden reduction of ionic conductivity, followed by a slow recovery, has been found to occur during testing of the solid electrolyte and electrode components of an alkali metal thermal-to-electric converter (AMTEC) cell. At this time, high-temperature tests of limited duration have indicated the superiority of the treated BASE, but reproducible tests over thousands of hours are necessary to confirm that microcracking has been eliminated. The ionic conductivity of the treated BASE is also measured to be higher than untreated BASE at 1,073 K in low-pressure sodium vapor. Microcracking resulting in loss of conductivity was not observed with treated BASE in one high-temperature experiment, but this result must be duplicated over very long testing times to be sure of the effect. Shorter annealing times (10 to 20 hours) were found to result in significantly less loss of mass; it may be necessary for the packed powder mixture to evolve some Na2O before the Na2O can leave the ceramic.

  7. Sealing of Base Wells, McClellan Air Force Base, California

    DTIC Science & Technology

    1984-02-15

    Slurry 111-16 Equipment Requirement 111-17 Inspection of the Well 111-18 Turbine Pump Repairs 111-18 Testing of the Well 111-19 Wells to be Sealed 111...hydrogeology underlying the Base, reviews the ES groundwater testing procedures and the conclusions reached by ES as a result of those tests , reviews...perform proper sealing, LSCE proposes that a preliminary engineering site investigation be conducted which would include test drilling and installation

  8. Creative Digital Worksheet Base on Mobile Learning

    NASA Astrophysics Data System (ADS)

    Wibawa, S. C.; Cholifah, R.; Utami, A. W.; Nurhidayat, A. I.

    2018-01-01

    The student is required to understand and act in the classroom and it is very important for selecting the media learning to determine the learning outcome. An instructional media is needed to help students achieve the best learning outcome. The objectives of this study are (1) to make Android-based student worksheet, (2) to know the students’ response on Android-based student worksheet in multimedia subject, (3) to determine the student result using Android-based student worksheet. The method used was Research and Development (R&D) using post-test-only in controlled quasi-experimental group design. The subjects of the study were 2 classes, a control class and an experimental class. The results showed (1) Android-based student worksheet was categorized very good as percentage of 85%; (2) the students’ responses was categorized very good as percentage of 86.42%; (3) the experimental class results were better than control class. The average result on cognitive tests on the experimental class was 89.97 and on control class was 78.31; whether the average result on psychomotor test on the experimental class was 89.90 and on the control class was 79.83. In conclusion, student result using Android-based student worksheet was better than those without it.

  9. Linkage to care following community-based mobile HIV testing compared with clinic-based testing in Umlazi Township, Durban, South Africa.

    PubMed

    Bassett, I V; Regan, S; Luthuli, P; Mbonambi, H; Bearnot, B; Pendleton, A; Robine, M; Mukuvisi, D; Thulare, H; Walensky, R P; Freedberg, K A; Losina, E; Mhlongo, B

    2014-07-01

    The aim of the study was to assess HIV prevalence, disease stage and linkage to HIV care following diagnosis at a mobile HIV testing unit, compared with results for clinic-based testing, in a Durban township. This was a prospective cohort study. We enrolled adults presenting for HIV testing at a community-based mobile testing unit (mobile testers) and at an HIV clinic (clinic testers) serving the same area. Testers diagnosed with HIV infection, regardless of testing site, were offered immediate CD4 testing and instructed to retrieve results at the clinic. We assessed rates of linkage to care, defined as CD4 result retrieval within 90 days of HIV diagnosis and/or completion of antiretroviral therapy (ART) literacy training, for mobile vs. clinic testers. From July to November 2011, 6957 subjects were HIV tested (4703 mobile and 2254 clinic); 55% were female. Mobile testers had a lower HIV prevalence than clinic testers (10% vs. 36%, respectively), were younger (median 23 vs. 27 years, respectively) and were more likely to live >5 km or >30 min from the clinic (64% vs. 40%, respectively; all P < 0.001). Mobile testers were less likely to undergo CD4 testing (33% vs. 83%, respectively) but more likely to have higher CD4 counts [median (interquartile range) 416 (287-587) cells/μL vs. 285 (136-482) cells/μL, respectively] than clinic testers (both P < 0.001). Of those who tested HIV positive, 10% of mobile testers linked to care, vs. 72% of clinic testers (P < 0.001). Mobile HIV testing reaches people who are younger, who are more geographically remote, and who have earlier disease compared with clinic-based testing. Fewer mobile testers underwent CD4 testing and linked to HIV care. Enhancing linkage efforts may improve the impact of mobile testing for those with early HIV disease. © 2013 British HIV Association.

  10. Routine use of point-of-care tests: usefulness and application in clinical microbiology.

    PubMed

    Clerc, O; Greub, G

    2010-08-01

    Point-of-care (POC) tests offer potentially substantial benefits for the management of infectious diseases, mainly by shortening the time to result and by making the test available at the bedside or at remote care centres. Commercial POC tests are already widely available for the diagnosis of bacterial and viral infections and for parasitic diseases, including malaria. Infectious diseases specialists and clinical microbiologists should be aware of the indications and limitations of each rapid test, so that they can use them appropriately and correctly interpret their results. The clinical applications and performance of the most relevant and commonly used POC tests are reviewed. Some of these tests exhibit insufficient sensitivity, and should therefore be coupled to confirmatory tests when the results are negative (e.g. Streptococcus pyogenes rapid antigen detection test), whereas the results of others need to be confirmed when positive (e.g. malaria). New molecular-based tests exhibit better sensitivity and specificity than former immunochromatographic assays (e.g. Streptococcus agalactiae detection). In the coming years, further evolution of POC tests may lead to new diagnostic approaches, such as panel testing, targeting not just a single pathogen, but all possible agents suspected in a specific clinical setting. To reach this goal, the development of serology-based and/or molecular-based microarrays/multiplexed tests will be needed. The availability of modern technology and new microfluidic devices will provide clinical microbiologists with the opportunity to be back at the bedside, proposing a large variety of POC tests that will allow quicker diagnosis and improved patient care.

  11. Test Scheduling for Core-Based SOCs Using Genetic Algorithm Based Heuristic Approach

    NASA Astrophysics Data System (ADS)

    Giri, Chandan; Sarkar, Soumojit; Chattopadhyay, Santanu

    This paper presents a Genetic algorithm (GA) based solution to co-optimize test scheduling and wrapper design for core based SOCs. Core testing solutions are generated as a set of wrapper configurations, represented as rectangles with width equal to the number of TAM (Test Access Mechanism) channels and height equal to the corresponding testing time. A locally optimal best-fit heuristic based bin packing algorithm has been used to determine placement of rectangles minimizing the overall test times, whereas, GA has been utilized to generate the sequence of rectangles to be considered for placement. Experimental result on ITC'02 benchmark SOCs shows that the proposed method provides better solutions compared to the recent works reported in the literature.

  12. A gel-based visual immunoassay for non-instrumental detection of chloramphenicol in food samples.

    PubMed

    Yuan, Meng; Sheng, Wei; Zhang, Yan; Wang, Junping; Yang, Yijin; Zhang, Shuguang; Goryacheva, Irina Yu; Wang, Shuo

    2012-11-02

    A gel-based non-instrumental immuno-affinity assay was developed for the rapid screening of chloramphenicol (CAP) in food samples with the limit of detection (LOD) of 1 μg L(-1). The immuno-affinity test column (IATC) consisted of a test layer containing anti-CAP antibody coupled gel, and a control layer with anti-HRP antibody coupled gel. Based on the direct competitive immuno-reaction and the horseradish peroxidase enzymatic reaction, the test results could be evaluated visually. Basically, blue color development represented the negative results, while the absence of color development represented the positive results. In this study, CAP spiked samples of raw milk, pasteurized milk, UHT milk, skimmed milk powder, acacia honey, date honey, fish and shrimp were tested. Little or none sample pretreatment was required for this assay. The whole procedure was completed within 10min. In conclusion, the gel-based immuno-affinity test is a simple, rapid, and promising on-site screening method for CAP residues in food samples, with no instrumental requirement. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Free-Suspension Residual Flexibility Testing of Space Station Pathfinder: Comparison to Fixed-Base Results

    NASA Technical Reports Server (NTRS)

    Tinker, Michael L.

    1998-01-01

    Application of the free-suspension residual flexibility modal test method to the International Space Station Pathfinder structure is described. The Pathfinder, a large structure of the general size and weight of Space Station module elements, was also tested in a large fixed-base fixture to simulate Shuttle Orbiter payload constraints. After correlation of the Pathfinder finite element model to residual flexibility test data, the model was coupled to a fixture model, and constrained modes and frequencies were compared to fixed-base test. modes. The residual flexibility model compared very favorably to results of the fixed-base test. This is the first known direct comparison of free-suspension residual flexibility and fixed-base test results for a large structure. The model correlation approach used by the author for residual flexibility data is presented. Frequency response functions (FRF) for the regions of the structure that interface with the environment (a test fixture or another structure) are shown to be the primary tools for model correlation that distinguish or characterize the residual flexibility approach. A number of critical issues related to use of the structure interface FRF for correlating the model are then identified and discussed, including (1) the requirement of prominent stiffness lines, (2) overcoming problems with measurement noise which makes the antiresonances or minima in the functions difficult to identify, and (3) the use of interface stiffness and lumped mass perturbations to bring the analytical responses into agreement with test data. It is shown that good comparison of analytical-to-experimental FRF is the key to obtaining good agreement of the residual flexibility values.

  14. Large-aperture space optical system testing based on the scanning Hartmann.

    PubMed

    Wei, Haisong; Yan, Feng; Chen, Xindong; Zhang, Hao; Cheng, Qiang; Xue, Donglin; Zeng, Xuefeng; Zhang, Xuejun

    2017-03-10

    Based on the Hartmann testing principle, this paper proposes a novel image quality testing technology which applies to a large-aperture space optical system. Compared with the traditional testing method through a large-aperture collimator, the scanning Hartmann testing technology has great advantages due to its simple structure, low cost, and ability to perform wavefront measurement of an optical system. The basic testing principle of the scanning Hartmann testing technology, data processing method, and simulation process are presented in this paper. Certain simulation results are also given to verify the feasibility of this technology. Furthermore, a measuring system is developed to conduct a wavefront measurement experiment for a 200 mm aperture optical system. The small deviation (6.3%) of root mean square (RMS) between experimental results and interferometric results indicates that the testing system can measure low-order aberration correctly, which means that the scanning Hartmann testing technology has the ability to test the imaging quality of a large-aperture space optical system.

  15. Dynamic simulation of a reverse Brayton refrigerator

    NASA Astrophysics Data System (ADS)

    Peng, N.; Lei, L. L.; Xiong, L. Y.; Tang, J. C.; Dong, B.; Liu, L. Q.

    2014-01-01

    A test refrigerator based on the modified Reverse Brayton cycle has been developed in the Chinese Academy of Sciences recently. To study the behaviors of this test refrigerator, a dynamic simulation has been carried out. The numerical model comprises the typical components of the test refrigerator: compressor, valves, heat exchangers, expander and heater. This simulator is based on the oriented-object approach and each component is represented by a set of differential and algebraic equations. The control system of the test refrigerator is also simulated, which can be used to optimize the control strategies. This paper describes all the models and shows the simulation results. Comparisons between simulation results and experimental data are also presented. Experimental validation on the test refrigerator gives satisfactory results.

  16. The construction of life prediction models for the design of Stirling engine heater components

    NASA Technical Reports Server (NTRS)

    Petrovich, A.; Bright, A.; Cronin, M.; Arnold, S.

    1983-01-01

    The service life of Stirling-engine heater structures of Fe-based high-temperature alloys is predicted using a numerical model based on a linear-damage approach and published test data (engine test data for a Co-based alloy and tensile-test results for both the Co-based and the Fe-based alloys). The operating principle of the automotive Stirling engine is reviewed; the economic and technical factors affecting the choice of heater material are surveyed; the test results are summarized in tables and graphs; the engine environment and automotive duty cycle are characterized; and the modeling procedure is explained. It is found that the statistical scatter of the fatigue properties of the heater components needs to be reduced (by decreasing the porosity of the cast material or employing wrought material in fatigue-prone locations) before the accuracy of life predictions can be improved.

  17. Cost-effectiveness of population-based screening for colorectal cancer: a comparison of guaiac-based faecal occult blood testing, faecal immunochemical testing and flexible sigmoidoscopy

    PubMed Central

    Sharp, L; Tilson, L; Whyte, S; O'Ceilleachair, A; Walsh, C; Usher, C; Tappenden, P; Chilcott, J; Staines, A; Barry, M; Comber, H

    2012-01-01

    Background: Several colorectal cancer-screening tests are available, but it is uncertain which provides the best balance of risks and benefits within a screening programme. We evaluated cost-effectiveness of a population-based screening programme in Ireland based on (i) biennial guaiac-based faecal occult blood testing (gFOBT) at ages 55–74, with reflex faecal immunochemical testing (FIT); (ii) biennial FIT at ages 55–74; and (iii) once-only flexible sigmoidoscopy (FSIG) at age 60. Methods: A state-transition model was used to estimate costs and outcomes for each screening scenario vs no screening. A third party payer perspective was adopted. Probabilistic sensitivity analyses were undertaken. Results: All scenarios would be considered highly cost-effective compared with no screening. The lowest incremental cost-effectiveness ratio (ICER vs no screening €589 per quality-adjusted life-year (QALY) gained) was found for FSIG, followed by FIT (€1696) and gFOBT (€4428); gFOBT was dominated. Compared with FSIG, FIT was associated with greater gains in QALYs and reductions in lifetime cancer incidence and mortality, but was more costly, required considerably more colonoscopies and resulted in more complications. Results were robust to variations in parameter estimates. Conclusion: Population-based screening based on FIT is expected to result in greater health gains than a policy of gFOBT (with reflex FIT) or once-only FSIG, but would require significantly more colonoscopy resources and result in more individuals experiencing adverse effects. Weighing these advantages and disadvantages presents a considerable challenge to policy makers. PMID:22343624

  18. Safety impact of an integrated crash warning system based on field test data.

    DOT National Transportation Integrated Search

    2011-06-13

    This paper provides the results of an analysis : conducted to assess the safety impact of an integrated : vehicle-based crash warning system based on : naturalistic driving data collected from a field : operational test. The system incorporates four ...

  19. Oscillating flow loss test results in Stirling engine heat exchangers

    NASA Technical Reports Server (NTRS)

    Koester, G.; Howell, S.; Wood, G.; Miller, E.; Gedeon, D.

    1990-01-01

    The results are presented for a test program designed to generate a database of oscillating flow loss information that is applicable to Stirling engine heat exchangers. The tests were performed on heater/cooler tubes of various lengths and entrance/exit configurations, on stacked and sintered screen regenerators of various wire diameters and on Brunswick and Metex random fiber regenerators. The test results were performed over a range of oscillating flow parameters consistent with Stirling engine heat exchanger experience. The tests were performed on the Sunpower oscillating flow loss rig which is based on a variable stroke and variable frequency linear drive motor. In general, the results are presented by comparing the measured oscillating flow losses to the calculated flow losses. The calculated losses are based on the cycle integration of steady flow friction factors and entrance/exit loss coefficients.

  20. The design and application of virtual ion meter based on LABVIEW 8.0.

    PubMed

    Meng, Hu; Li, Jiangyuan; Tang, Yonghuai

    2009-08-01

    The virtual ion meter is developed based on LABVIEW 8.0 by homemade adjusting circuit, data acquisition (DAQ) board, and computer. This note provides details of the structure of testing system and flow chart of DAQ program. This virtual instrument system is applied to multitask testing such as determining rate constant of second-order reaction by pX, pX potentiometric titration, determining oscillating reaction by potential, etc. The result of application indicates that this test system not only has function of real-time data acquiring, displaying, storage, but also realizes remote monitoring and controlling test-control spots through internet, automatic analyzing and processing of data, reporting of result according to the different testing task; moreover, the veracity and repeatability of data processing result are higher than the results of manual data processing.

  1. Scaled Rocket Testing in Hypersonic Flow

    NASA Technical Reports Server (NTRS)

    Dufrene, Aaron; MacLean, Matthew; Carr, Zakary; Parker, Ron; Holden, Michael; Mehta, Manish

    2015-01-01

    NASA's Space Launch System (SLS) uses four clustered liquid rocket engines along with two solid rocket boosters. The interaction between all six rocket exhaust plumes will produce a complex and severe thermal environment in the base of the vehicle. This work focuses on a recent 2% scale, hot-fire SLS base heating test. These base heating tests are short-duration tests executed with chamber pressures near the full-scale values with gaseous hydrogen/oxygen engines and RSRMV analogous solid propellant motors. The LENS II shock tunnel/Ludwieg tube tunnel was used at or near flight duplicated conditions up to Mach 5. Model development was strongly based on the Space Shuttle base heating tests with several improvements including doubling of the maximum chamber pressures and duplication of freestream conditions. Detailed base heating results are outside of the scope of the current work, rather test methodology and techniques are presented along with broader applicability toward scaled rocket testing in supersonic and hypersonic flow.

  2. An observational study of the impact of genetic testing for pain perception in the clinical management of chronic non-cancer pain.

    PubMed

    Sharma, Maneesh; Kantorovich, Svetlana; Lee, Chee; Anand, Natasha; Blanchard, John; Fung, Eric T; Meshkin, Brian; Brenton, Ashley; Richeimer, Steven

    2017-06-01

    Pain levels are a key metric in clinical care. However, the assessment of pain is limited to basic questionnaires and physician interpretation, which yield subjective data. Genetic markers of pain sensitivity, such as single nucleotide polymorphisms in the catechol-O-methyltransferase gene, have been shown to be associated with pain perception and have been used to provide objective information about a patient's pain. The goal of this study was to determine if physician treatment adjustments based on genetic tests of pain perception resulted in improved outcomes for patients. A prospective, longitudinal study was conducted with 134 chronic non-cancer pain patients genotyped for pain perception-related catechol-O-methyltransferase haplotypes. Physicians were provided with patients' results and asked to document 1) their assessment of benefit of the genetic test; 2) treatment changes made based on the genetic test; and 3) patient clinical responses to changes implemented. Based on genetic testing results, physicians adjusted treatment plans for 40% of patients. When medication changes were made based on genetic testing results, 72% of patients showed improvement in clinical status. When non-pharmacological actions were performed, 69% of physicians felt their patients' clinical status improved. Moreover, physicians believed the genetic test results were consistent with patient pain levels in 85% of cases. These results demonstrate that providing personalized medicine with genetic information related to pain perception affected physician clinical decision-making for a substantial proportion of patients in this study, and that the availability and utilization of this information was a contributing factor in clinical improvement. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Verification of a ground-based method for simulating high-altitude, supersonic flight conditions

    NASA Astrophysics Data System (ADS)

    Zhou, Xuewen; Xu, Jian; Lv, Shuiyan

    Ground-based methods for accurately representing high-altitude, high-speed flight conditions have been an important research topic in the aerospace field. Based on an analysis of the requirements for high-altitude supersonic flight tests, a ground-based test bed was designed combining Laval nozzle, which is often found in wind tunnels, with a rocket sled system. Sled tests were used to verify the performance of the test bed. The test results indicated that the test bed produced a uniform-flow field with a static pressure and density equivalent to atmospheric conditions at an altitude of 13-15km and at a flow velocity of approximately M 2.4. This test method has the advantages of accuracy, fewer experimental limitations, and reusability.

  4. Illegal performance enhancing drugs and doping in sport: a picture-based brief implicit association test for measuring athletes’ attitudes

    PubMed Central

    2014-01-01

    Background Doping attitude is a key variable in predicting athletes’ intention to use forbidden performance enhancing drugs. Indirect reaction-time based attitude tests, such as the implicit association test, conceal the ultimate goal of measurement from the participant better than questionnaires. Indirect tests are especially useful when socially sensitive constructs such as attitudes towards doping need to be described. The present study serves the development and validation of a novel picture-based brief implicit association test (BIAT) for testing athletes’ attitudes towards doping in sport. It shall provide the basis for a transnationally compatible research instrument able to harmonize anti-doping research efforts. Method Following a known-group differences validation strategy, the doping attitudes of 43 athletes from bodybuilding (representative for a highly doping prone sport) and handball (as a contrast group) were compared using the picture-based doping-BIAT. The Performance Enhancement Attitude Scale (PEAS) was employed as a corresponding direct measure in order to additionally validate the results. Results As expected, in the group of bodybuilders, indirectly measured doping attitudes as tested with the picture-based doping-BIAT were significantly less negative (η2 = .11). The doping-BIAT and PEAS scores correlated significantly at r = .50 for bodybuilders, and not significantly at r = .36 for handball players. There was a low error rate (7%) and a satisfactory internal consistency (r tt  = .66) for the picture-based doping-BIAT. Conclusions The picture-based doping-BIAT constitutes a psychometrically tested method, ready to be adopted by the international research community. The test can be administered via the internet. All test material is available “open source”. The test might be implemented, for example, as a new effect-measure in the evaluation of prevention programs. PMID:24479865

  5. Clinic-based testing for rectal and pharyngeal Neisseria gonorrhoeae and Chlamydia trachomatis infections by community-based organizations--five cities, United States, 2007.

    PubMed

    2009-07-10

    CDC recommends screening of at-risk men who have sex with men (MSM) at least annually for urethral and rectal gonorrhea and chlamydia, and for pharyngeal gonorrhea. Although the standard method for diagnosis is culture, nucleic acid amplification (NAA) testing is generally more sensitive and favored by most experts. NAA tests have not been cleared by the Food and Drug Administration (FDA) for the diagnosis of extragenital chlamydia or gonorrhea and may not be marketed for that purpose. However, under U.S. law, laboratories may offer NAA testing for diagnosis of extragenital chlamydia or gonorrhea after internal validation of the method by a verification study. To determine sexually transmitted disease (STD) testing practices among community-based organizations serving MSM, CDC and the San Francisco Department of Public Health gathered data on rectal and pharyngeal gonorrhea and chlamydia testing at screening sites managed by six gay-focused community-based organizations in five U.S. cities during 2007. This report summarizes the results of the study, which found that three organizations collected samples for NAA testing and three for culture. In total, approximately 30,000 tests were performed; 5.4% of rectal gonorrhea, 8.9% of rectal chlamydia, 5.3% of pharyngeal gonorrhea, and 1.6% of pharyngeal chlamydia tests were positive. These results demonstrate that gay-focused community-based organizations can detect large numbers of gonorrhea and chlamydia cases and might reach MSM not being tested elsewhere. Public health officials could consider providing support to certain community-based organizations to facilitate testing and treatment of gonorrhea and chlamydia.

  6. Update on HER2 testing for breast and upper gastrointestinal tract cancers.

    PubMed

    Ross, Jeffrey S

    2011-06-01

    With the regulatory approvals in Europe and the USA of trastuzumab-based anti-HER2 targeted therapy for upper gastrointestinal cancers in 2010, HER2 testing has now become universal for newly diagnosed cases of both breast cancer and adenocarcinomas of esophagus, stomach and gastroesophageal origin. In the 12 years or more since the approval of trastuzumab for breast cancer, general refinements in approaches to HER2 testing, including a greater understanding of the implications of preanalytic factors impacting the test results and the application of standardization of reporting of HER2 test results, have taken place. There has also been continuing development in breast cancer with the introduction of new HER2 tests, including non-FISH tests, dimerization assays, phosphorylated HER2 receptor tests, mRNA-based tests, HER2 gene sequencing tests and the application of HER2 testing to circulating tumor cells. Most recently, the introduction of HER2 testing for upper gastrointentinal malignancies has emphasized the need for performing and interpreting slide-based assays in a manner unique to these specimens and not to apply the breast cancer testing protocols to esophageal and gastric adenocarcinomas.

  7. Ethernet-based test stand for a CAN network

    NASA Astrophysics Data System (ADS)

    Ziebinski, Adam; Cupek, Rafal; Drewniak, Marek

    2017-11-01

    This paper presents a test stand for the CAN-based systems that are used in automotive systems. The authors propose applying an Ethernet-based test system that supports the virtualisation of a CAN network. The proposed solution has many advantages compared to classical test beds that are based on dedicated CAN-PC interfaces: it allows the physical constraints associated with the number of interfaces that can be simultaneously connected to a tested system to be avoided, which enables the test time for parallel tests to be shortened; the high speed of Ethernet transmission allows for more frequent sampling of the messages that are transmitted by a CAN network (as the authors show in the experiment results section) and the cost of the proposed solution is much lower than the traditional lab-based dedicated CAN interfaces for PCs.

  8. The performance of multimodal hyperspectral spectroscopy in the detection of precancerous cervical lesions

    NASA Astrophysics Data System (ADS)

    Trahmono; Lusiana, N.; Indarti, J.

    2017-08-01

    The aim of this study was to compare the performance of multimodal hyperspectral spectroscopy (MHS), which combines fluorescence and reflectance spectroscopy, with that of conventional laboratory-based screening tests, such as the Papanicolaou (Pap) smear test and human papilloma virus (HPV) DNA test, for detecting precancerous lesions of the cervix. The study utilized a cross-sectional design, and the kappa test was used in the analytical assessment. MHS scans were obtained from a sample of 70 consecutive patients, followed by sample collection for Pap and HPV DNA analysis and colposcopy referral, if indicated. Of the 70 patients evaluated, the results of cervical spectroscopy were normal in 38 (54.3%) patients, and they were abnormal in 32 (45.7%) patients. Based on the cytology results, 45 (64.3%) samples were normal, and 25 (35.7%) samples were abnormal. According to the results of the HPV DNA test, 47 (67.14%) samples were normal, and 17 (24.28%) samples were abnormal. Based on the results of the kappa test, the agreement between MHS and cytology was 0.793 (p < 0.001). The agreement between MHS and the HPV DNA test was 0.195 (p = 0.086), and the agreement between MHS and colposcopy was 0.479 (p < 0.001).

  9. Validation of a Video-based Game-Understanding Test Procedure in Badminton.

    ERIC Educational Resources Information Center

    Blomqvist, Minna T.; Luhtanen, Pekka; Laakso, Lauri; Keskinen, Esko

    2000-01-01

    Reports the development and validation of video-based game-understanding tests in badminton for elementary and secondary students. The tests included different sequences that simulated actual game situations. Players had to solve tactical problems by selecting appropriate solutions and arguments for their decisions. Results suggest that the test…

  10. Conceptualizing Teaching to the Test under Standards-Based Reform

    ERIC Educational Resources Information Center

    Welsh, Megan E.; Eastwood, Melissa; D'Agostino, Jerome V.

    2014-01-01

    Teacher and school accountability systems based on high-stakes tests are ubiquitous throughout the United States and appear to be growing as a catalyst for reform. As a result, educators have increased the proportion of instructional time devoted to test preparation. Although guidelines for what constitutes appropriate and inappropriate test…

  11. Impact of Learning Model Based on Cognitive Conflict toward Student’s Conceptual Understanding

    NASA Astrophysics Data System (ADS)

    Mufit, F.; Festiyed, F.; Fauzan, A.; Lufri, L.

    2018-04-01

    The problems that often occur in the learning of physics is a matter of misconception and low understanding of the concept. Misconceptions do not only happen to students, but also happen to college students and teachers. The existing learning model has not had much impact on improving conceptual understanding and remedial efforts of student misconception. This study aims to see the impact of cognitive-based learning model in improving conceptual understanding and remediating student misconceptions. The research method used is Design / Develop Research. The product developed is a cognitive conflict-based learning model along with its components. This article reports on product design results, validity tests, and practicality test. The study resulted in the design of cognitive conflict-based learning model with 4 learning syntaxes, namely (1) preconception activation, (2) presentation of cognitive conflict, (3) discovery of concepts & equations, (4) Reflection. The results of validity tests by some experts on aspects of content, didactic, appearance or language, indicate very valid criteria. Product trial results also show a very practical product to use. Based on pretest and posttest results, cognitive conflict-based learning models have a good impact on improving conceptual understanding and remediating misconceptions, especially in high-ability students.

  12. Can Internet-Based Sexual Health Services Increase Diagnoses of Sexually Transmitted Infections (STI)? Protocol for a Randomized Evaluation of an Internet-Based STI Testing and Results Service.

    PubMed

    Wilson, Emma; Free, Caroline; Morris, Tim P; Kenward, Michael G; Syred, Jonathan; Baraitser, Paula

    2016-01-15

    Ensuring rapid access to high quality sexual health services is a key public health objective, both in the United Kingdom and internationally. Internet-based testing services for sexually transmitted infections (STIs) are considered to be a promising way to achieve this goal. This study will evaluate a nascent online STI testing and results service in South East London, delivered alongside standard face-to-face STI testing services. The aim of this study is to establish whether an online testing and results services can (1) increase diagnoses of STIs and (2) increase uptake of STI testing, when delivered alongside standard face-to-face STI testing services. This is a single-blind randomized controlled trial. We will recruit 3000 participants who meet the following eligibility criteria: 16-30 years of age, resident in the London boroughs of Lambeth and Southwark, having at least one sexual partner in the last 12 months, having access to the Internet and willing to take an STI test. People unable to provide informed consent and unable to read and understand English (the websites will be in English) will be excluded. Baseline data will be collected at enrolment. This includes participant contact details, demographic data (date of birth, gender, ethnicity, and sexual orientation), and sexual health behaviors (last STI test, service used at last STI test and number of sexual partners in the last 12 months). Once enrolled, participants will be randomly allocated either (1) to an online STI testing and results service (Sexual Health 24) offering postal self-administered STI kits for chlamydia, gonorrhoea, syphilis, and HIV; results via text message (short message service, SMS), except positive results for HIV, which will be delivered by phone; and direct referrals to local clinics for treatment or (2) to a conventional sexual health information website with signposting to local clinic-based sexual health services. Participants will be free to use any other interventions or services during the trial period. At 6 weeks from randomization we will collect self-reported follow-up data on service use, STI tests and results, treatment prescribed, and acceptability of STI testing services. We will also collect objective data from participating STI testing services on uptake of STI testing, STI diagnoses and treatment. We hypothesise that uptake of STI testing and STI diagnoses will be higher in the intervention arm. Our hypothesis is based on the assumption that the intervention is less time-consuming, more convenient, more private, and incur less stigma and embarrassment than face-to-face STI testing pathways. The primary outcome measure is diagnosis of any STI at 6 weeks from randomization and our co-primary outcome is completion of any STI test at 6 weeks from randomization. We define completion of a test, as samples returned, processed, and results delivered to the intervention and/or clinic settings. We will use risk ratios to calculate the effect of the intervention on our primary outcomes with 95% confidence intervals. All analyses will be based on the intention-to-treat (ITT) principle. This study is funded by Guy's and St Thomas' Charity and it has received ethical approval from NRES Committee London-Camberwell St Giles (Ref 14/LO/1477). Research and Development approval has been obtained from Kings College Hospital NHS Foundation Trust and Guy's and St Thomas' NHS Foundation Trust. Results are expected in June 2016. This study will provide evidence on the effectiveness of an online STI testing and results service in South East London. Our findings may also be generalizable to similar populations in the United Kingdom. International Standard Randomized Controlled Trial Number (ISRCTN): 13354298; http://www.isrctn.com/ISRCTN13354298 (Archived by WebCite at http://www.webcitation.org/6d9xT2bPj).

  13. In Silico Testing of an Artificial-Intelligence-Based Artificial Pancreas Designed for Use in the Intensive Care Unit Setting

    PubMed Central

    DeJournett, Leon; DeJournett, Jeremy

    2016-01-01

    Background: Effective glucose control in the intensive care unit (ICU) setting has the potential to decrease morbidity and mortality rates which should in turn lead to decreased health care expenditures. Current ICU-based glucose controllers are mathematically derived, and tend to be based on proportional integral derivative (PID) or model predictive control (MPC). Artificial intelligence (AI)–based closed loop glucose controllers may have the ability to achieve control that improves on the results achieved by either PID or MPC controllers. Method: We conducted an in silico analysis of an AI-based glucose controller designed for use in the ICU setting. This controller was tested using a mathematical model of the ICU patient’s glucose-insulin system. A total of 126 000 unique 5-day simulations were carried out, resulting in 107 million glucose values for analysis. Results: For the 7 control ranges tested, with a sensor error of ±10%, the following average results were achieved: (1) time in control range, 94.2%, (2) time in range 70-140 mg/dl, 97.8%, (3) time in hyperglycemic range (>140 mg/dl), 2.1%, and (4) time in hypoglycemic range (<70 mg/dl), 0.09%. In addition, the average coefficient of variation (CV) was 11.1%. Conclusions: This in silico study of an AI-based closed loop glucose controller shows that it may be able to improve on the results achieved by currently existing ICU-based PID/MPC controllers. If these results are confirmed in clinical testing, this AI-based controller could be used to create an artificial pancreas system for use in the ICU setting. PMID:27301982

  14. Development of Two-Tier Diagnostic Test Pictorial-Based for Identifying High School Students Misconceptions on the Mole Concept

    NASA Astrophysics Data System (ADS)

    Siswaningsih, W.; Firman, H.; Zackiyah; Khoirunnisa, A.

    2017-02-01

    The aim of this study was to develop the two-tier pictorial-based diagnostic test for identifying student misconceptions on mole concept. The method of this study is used development and validation. The development of the test Obtained through four phases, development of any items, validation, determination key, and application test. Test was developed in the form of pictorial consisting of two tier, the first tier Consist of four possible answers and the second tier Consist of four possible reasons. Based on the results of content validity of 20 items using the CVR (Content Validity Ratio), a number of 18 items declared valid. Based on the results of the reliability test using SPSS, Obtained 17 items with Cronbach’s Alpha value of 0703, the which means that items have accepted. A total of 10 items was conducted to 35 students of senior high school students who have studied the mole concept on one of the high schools in Cimahi. Based on the results of the application test, student misconceptions were identified in each label concept in mole concept with the percentage of misconceptions on the label concept of mole (60.15%), Avogadro’s number (34.28%), relative atomic mass (62, 84%), relative molecule mass (77.08%), molar mass (68.53%), molar volume of gas (57.11%), molarity (71.32%), chemical equation (82.77%), limiting reactants (91.40%), and molecular formula (77.13%).

  15. Do sediment type and test durations affect results of laboratory-based, accelerated testing studies of permeable pavement clogging?

    PubMed

    Nichols, Peter W B; White, Richard; Lucke, Terry

    2015-04-01

    Previous studies have attempted to quantify the clogging processes of Permeable Interlocking Concrete Pavers (PICPs) using accelerated testing methods. However, the results have been variable. This study investigated the effects that three different sediment types (natural and silica), and different simulated rainfall intensities, and testing durations had on the observed clogging processes (and measured surface infiltration rates) of laboratory-based, accelerated PICP testing studies. Results showed that accelerated simulated laboratory testing results are highly dependent on the type, and size of sediment used in the experiments. For example, when using real stormwater sediment up to 1.18 mm in size, the results showed that neither testing duration, nor stormwater application rate had any significant effect on PICP clogging. However, the study clearly showed that shorter testing durations generally increased clogging and reduced the surface infiltration rates of the models when artificial silica sediment was used. Longer testing durations also generally increased clogging of the models when using fine sediment (<300 μm). Results from this study will help researchers and designers better anticipate when and why PICPs are susceptible to clogging, reduce maintenance and extend the useful life of these increasingly common stormwater best management practices. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. The Effects of Eccentric, Velocity-Based Training on Strength and Power in Collegiate Athletes

    PubMed Central

    DOLEZAL, SAMANTHA M.; FRESE, DEREK L.; LLEWELLYN, TAMRA L.

    2016-01-01

    The purpose of this study was to determine if combining velocity-based training with eccentric focus (VEB) and velocity-based training (VBT) results in power and strength gains. Nineteen men and women collegiate track and field athletes participated in this study. The subjects completed a 12-week intervention with either a VEB program or a VBT program. To determine the effectiveness of each program, the subjects completed four exercise tests before and after the training period: vertical jump, medicine ball put test, 1RM projected bench press and 1RM projected squat. There were no significant differences between the VBT results and the VEB results. However, there were significant improvements between the pre-test and post-test measures for each group. There were increases in 1RM projected squat for VEB men, VBT men, and VBT women. There were also significant improvements in the VEB male vertical jump and medicine ball put test pre- to post-intervention. For track and field athletes, both programs may result in strength and power gains, however, the results cannot be used to conclude that one resistance training program is superior. PMID:27990226

  17. The Effects of Eccentric, Velocity-Based Training on Strength and Power in Collegiate Athletes.

    PubMed

    Dolezal, Samantha M; Frese, Derek L; Llewellyn, Tamra L

    2016-01-01

    The purpose of this study was to determine if combining velocity-based training with eccentric focus (VEB) and velocity-based training (VBT) results in power and strength gains. Nineteen men and women collegiate track and field athletes participated in this study. The subjects completed a 12-week intervention with either a VEB program or a VBT program. To determine the effectiveness of each program, the subjects completed four exercise tests before and after the training period: vertical jump, medicine ball put test, 1RM projected bench press and 1RM projected squat. There were no significant differences between the VBT results and the VEB results. However, there were significant improvements between the pre-test and post-test measures for each group. There were increases in 1RM projected squat for VEB men, VBT men, and VBT women. There were also significant improvements in the VEB male vertical jump and medicine ball put test pre- to post-intervention. For track and field athletes, both programs may result in strength and power gains, however, the results cannot be used to conclude that one resistance training program is superior.

  18. A Comment on Early Student Blunders on Computer-Based Adaptive Tests

    ERIC Educational Resources Information Center

    Green, Bert F.

    2011-01-01

    This article refutes a recent claim that computer-based tests produce biased scores for very proficient test takers who make mistakes on one or two initial items and that the "bias" can be reduced by using a four-parameter IRT model. Because the same effect occurs with pattern scores on nonadaptive tests, the effect results from IRT scoring, not…

  19. Integrating Multiple On-line Knowledge Bases for Disease-Lab Test Relation Extraction.

    PubMed

    Zhang, Yaoyun; Soysal, Ergin; Moon, Sungrim; Wang, Jingqi; Tao, Cui; Xu, Hua

    2015-01-01

    A computable knowledge base containing relations between diseases and lab tests would be a great resource for many biomedical informatics applications. This paper describes our initial step towards establishing a comprehensive knowledge base of disease and lab tests relations utilizing three public on-line resources. LabTestsOnline, MedlinePlus and Wikipedia are integrated to create a freely available, computable disease-lab test knowledgebase. Disease and lab test concepts are identified using MetaMap and relations between diseases and lab tests are determined based on source-specific rules. Experimental results demonstrate a high precision for relation extraction, with Wikipedia achieving the highest precision of 87%. Combining the three sources reached a recall of 51.40%, when compared with a subset of disease-lab test relations extracted from a reference book. Moreover, we found additional disease-lab test relations from on-line resources, indicating they are complementary to existing reference books for building a comprehensive disease and lab test relation knowledge base.

  20. Aerodynamic flight evaluation analysis and data base update

    NASA Technical Reports Server (NTRS)

    Boyle, W. W.; Miller, M. S.; Wilder, G. O.; Reheuser, R. D.; Sharp, R. S.; Bridges, G. I.

    1989-01-01

    Research was conducted to determine the feasibility of replacing the Solid Rocket Boosters on the existing Space Shuttle Launch Vehicle (SSLV) with Liquid Rocket Boosters (LRB). As a part of the LRB selection process, a series of wind tunnel tests were conducted along with aero studies to determine the effects of different LRB configurations on the SSLV. Final results were tabulated into increments and added to the existing SSLV data base. The research conducted in this study was taken from a series of wind tunnel tests conducted at Marshall's 14-inch Trisonic Wind Tunnel. The effects on the axial force (CAF), normal force (CNF), pitching moment (CMF), side force (CY), wing shear force (CSR), wing torque moment (CTR), and wing bending moment (CBR) coefficients were investigated for a number of candidate LRB configurations. The aero effects due to LRB protuberances, ET/LRB separation distance, and aft skirts were also gathered from the tests. Analysis was also conducted to investigate the base pressure and plume effects due to the new booster geometries. The test results found in Phases 1 and 2 of wind tunnel testing are discussed and compared. Preliminary LRB lateral/directional data results and trends are given. The protuberance and gap/skirt effects are discussed. The base pressure/plume effects study is discussed and results are given.

  1. The space shuttle ascent vehicle aerodynamic challenges configuration design and data base development

    NASA Technical Reports Server (NTRS)

    Dill, C. C.; Young, J. C.; Roberts, B. B.; Craig, M. K.; Hamilton, J. T.; Boyle, W. W.

    1985-01-01

    The phase B Space Shuttle systems definition studies resulted in a generic configuration consisting of a delta wing orbiter, and two solid rocket boosters (SRB) attached to an external fuel tank (ET). The initial challenge facing the aerodynamic community was aerodynamically optimizing, within limits, this configuration. As the Shuttle program developed and the sensitivities of the vehicle to aerodynamics were better understood the requirements of the aerodynamic data base grew. Adequately characterizing the vehicle to support the various design studies exploded the size of the data base to proportions that created a data modeling/management challenge for the aerodynamicist. The ascent aerodynamic data base originated primarily from wind tunnel test results. The complexity of the configuration rendered conventional analytic methods of little use. Initial wind tunnel tests provided results which included undesirable effects from model support tructure, inadequate element proximity, and inadequate plume simulation. The challenge to improve the quality of test results by determining the extent of these undesirable effects and subsequently develop testing techniques to eliminate them was imposed on the aerodynamic community. The challenges to the ascent aerodynamics community documented are unique due to the aerodynamic complexity of the Shuttle launch. Never before was such a complex vehicle aerodynamically characterized. The challenges were met with innovative engineering analyses/methodology development and wind tunnel testing techniques.

  2. Tuberculin Skin Tests versus Interferon-Gamma Release Assays in Tuberculosis Screening among Immigrant Visa Applicants.

    PubMed

    Chuke, Stella O; Yen, Nguyen Thi Ngoc; Laserson, Kayla F; Phuoc, Nguyen Huu; Trinh, Nguyen An; Nhung, Duong Thi Cam; Mai, Vo Thi Chi; Qui, An Dang; Hai, Hoang Hoa; Loan, Le Thien Huong; Jones, Warren G; Whitworth, William C; Shah, J Jina; Painter, John A; Mazurek, Gerald H; Maloney, Susan A

    2014-01-01

    Objective. Use of tuberculin skin tests (TSTs) and interferon gamma release assays (IGRAs) as part of tuberculosis (TB) screening among immigrants from high TB-burden countries has not been fully evaluated. Methods. Prevalence of Mycobacterium tuberculosis infection (MTBI) based on TST, or the QuantiFERON-TB Gold test (QFT-G), was determined among immigrant applicants in Vietnam bound for the United States (US); factors associated with test results and discordance were assessed; predictive values of TST and QFT-G for identifying chest radiographs (CXRs) consistent with TB were calculated. Results. Of 1,246 immigrant visa applicants studied, 57.9% were TST positive, 28.3% were QFT-G positive, and test agreement was 59.4%. Increasing age was associated with positive TST results, positive QFT-G results, TST-positive but QFT-G-negative discordance, and abnormal CXRs consistent with TB. Positive predictive values of TST and QFT-G for an abnormal CXR were 25.9% and 25.6%, respectively. Conclusion. The estimated prevalence of MTBI among US-bound visa applicants in Vietnam based on TST was twice that based on QFT-G, and 14 times higher than a TST-based estimate of MTBI prevalence reported for the general US population in 2000. QFT-G was not better than TST at predicting abnormal CXRs consistent with TB.

  3. A low-cost mobile adaptive tracking system for chronic pulmonary patients in home environment.

    PubMed

    Işik, Ali Hakan; Güler, Inan; Sener, Melahat Uzel

    2013-01-01

    The main objective of this study is presenting a real-time mobile adaptive tracking system for patients diagnosed with diseases such as asthma or chronic obstructive pulmonary disease and application results at home. The main role of the system is to support and track chronic pulmonary patients in real time who are comfortable in their home environment. It is not intended to replace the doctor, regular treatment, and diagnosis. In this study, the Java 2 micro edition-based system is integrated with portable spirometry, smartphone, extensible markup language-based Web services, Web server, and Web pages for visualizing pulmonary function test results. The Bluetooth(®) (Bluetooth SIG, Kirkland, WA) virtual serial port protocol is used to obtain the test results from spirometry. General packet radio service, wireless local area network, or third-generation-based wireless networks are used to send the test results from a smartphone to the remote database. The system provides real-time classification of test results with the back propagation artificial neural network algorithm on a mobile smartphone. It also provides the generation of appropriate short message service-based notification and sending of all data to the Web server. In this study, the test results of 486 patients, obtained from Atatürk Chest Diseases and Thoracic Surgery Training and Research Hospital in Ankara, Turkey, are used as the training and test set in the algorithm. The algorithm has 98.7% accuracy, 97.83% specificity, 97.63% sensitivity, and 0.946 correlation values. The results show that the system is cheap (900 Euros) and reliable. The developed real-time system provides improvement in classification accuracy and facilitates tracking of chronic pulmonary patients.

  4. Tuberculosis Infection in Urban Adolescents: Results of a School-Based Testing Program.

    ERIC Educational Resources Information Center

    Barry, M. Anita; And Others

    1990-01-01

    Discusses a tuberculosis skin testing program introduced for seventh and tenth grade students in Boston (Massachusetts) public schools. Positivity rate was significantly higher in tenth grade students. Among those testing positive, the majority were born outside the United States. Results suggest that testing may identify a significant number of…

  5. Detection of fetal sex chromosome aneuploidy by massively parallel sequencing of maternal plasma DNA: initial experience in a Chinese hospital.

    PubMed

    Yao, H; Jiang, F; Hu, H; Gao, Y; Zhu, Z; Zhang, H; Wang, Y; Guo, Y; Liu, L; Yuan, Y; Zhou, L; Wang, J; Du, B; Qu, N; Zhang, R; Dong, Y; Xu, H; Chen, F; Jiang, H; Liu, Y; Zhang, L; Tian, Z; Liu, Q; Zhang, C; Pan, X; Yang, S; Zhao, L; Wang, W; Liang, Z

    2014-07-01

    To evaluate the performance of a massively parallel sequencing (MPS)-based test in detecting fetal sex chromosome aneuploidy (SCA) and to present a comprehensive clinical counseling protocol for SCA-positive patients. This was a retrospective study in a large patient cohort of 5950 singleton pregnancies which underwent MPS-based testing as a prenatal screening test for trisomies 21, 18 and 13, with X and Y chromosomes as secondary findings, in Southwest Hospital in China. MPS-based SCA-positive women were offered the choice of knowing whether their SCA results were positive and those who did commenced a two-stage post-test clinical counseling protocol. In Stage 1, general information about SCA was given, and women were given the option of invasive testing for confirmation of findings; in Stage 2, those who had chosen to undergo invasive testing were informed about the specific SCA affecting their fetus and their management options. Thirty-three cases were classified as SCA-positive by MPS-based testing. After Stage 1 of the two-stage post-test clinical counseling session, 33 (100%) of these pregnant women chose to know the screening test results, and 25 (75.76%) underwent an invasive diagnostic procedure and karyotype analysis, in one of whom karyotyping failed. In thirteen cases, karyotyping confirmed the MPS-based test results (two X0 cases, seven XXX cases, three XXY cases and one XYY case), giving a positive predictive value of 54.17% (13/24 cases confirmed by karyotyping). After post-test clinical counseling session Stage 2, seven women chose to terminate the pregnancy: one X0 case, two XXX cases, the three XXY cases and the single XYY case. Six women decided to continue with pregnancy: one X0 case and five XXX cases. Our study showed the feasibility of clinical application of the MPS-based test in the non-invasive detection of fetal SCA. Together with a two-stage post-test clinical counseling protocol, it leads to a well-informed decision-making procedure. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  6. Initial validation of a web-based self-administered neuropsychological test battery for older adults and seniors

    PubMed Central

    Hansen, Tor Ivar; Haferstrom, Elise Christina D.; Brunner, Jan F.; Lehn, Hanne; Håberg, Asta Kristine

    2015-01-01

    Introduction: Computerized neuropsychological tests are effective in assessing different cognitive domains, but are often limited by the need of proprietary hardware and technical staff. Web-based tests can be more accessible and flexible. We aimed to investigate validity, effects of computer familiarity, education, and age, and the feasibility of a new web-based self-administered neuropsychological test battery (Memoro) in older adults and seniors. Method: A total of 62 (37 female) participants (mean age 60.7 years) completed the Memoro web-based neuropsychological test battery and a traditional battery composed of similar tests intended to measure the same cognitive constructs. Participants were assessed on computer familiarity and how they experienced the two batteries. To properly test the factor structure of Memoro, an additional factor analysis in 218 individuals from the HUNT population was performed. Results: Comparing Memoro to traditional tests, we observed good concurrent validity (r = .49–.63). The performance on the traditional and Memoro test battery was consistent, but differences in raw scores were observed with higher scores on verbal memory and lower in spatial memory in Memoro. Factor analysis indicated two factors: verbal and spatial memory. There were no correlations between test performance and computer familiarity after adjustment for age or age and education. Subjects reported that they preferred web-based testing as it allowed them to set their own pace, and they did not feel scrutinized by an administrator. Conclusions: Memoro showed good concurrent validity compared to neuropsychological tests measuring similar cognitive constructs. Based on the current results, Memoro appears to be a tool that can be used to assess cognitive function in older and senior adults. Further work is necessary to ascertain its validity and reliability. PMID:26009791

  7. Containment testing of isolation rooms.

    PubMed

    Rydock, J P; Eian, P K

    2004-07-01

    Results from the tracer containment testing of four 'state-of-the-art' airborne infection isolation rooms, in a new hospital, are presented. A testing technician exited an isolation room several minutes after a small quantity of tracer gas was injected over the patient bed in that room. Easily measurable tracer gas concentrations were then found in the anterooms outside the patient rooms and corridor outside the isolation room suites. Containment factors for the isolation rooms and dilution factors in the anterooms and corridor were calculated, based on the measured tracer concentrations. These results indicate the desirability of evidence-based design standards and guidelines for assessing performance of airborne infection isolation rooms. The study also demonstrates that the tracer testing procedure yields comparable results for equivalent isolation room suites, suggesting good reproducibility of the testing method.

  8. The ACVD task force on canine atopic dermatitis (XVI): laboratory evaluation of dogs with atopic dermatitis with serum-based "allergy" tests.

    PubMed

    DeBoer, D J; Hillier, A

    2001-09-20

    Serum-based in vitro "allergy tests" are commercially available to veterinarians, and are widely used in diagnostic evaluation of a canine atopic patient. Following initial clinical diagnosis, panels of allergen-specific IgE measurements may be performed in an attempt to identify to which allergens the atopic dog is hypersensitive. Methodology for these tests varies by laboratory; few critical studies have evaluated performance of these tests, and current inter-laboratory standardization and quality control measures are inadequate. Other areas where information is critically limited include the usefulness of these tests in diagnosis of food allergy, the effect of extrinsic factors such as season of the year on results, and the influence of corticosteroid treatment on test results. Allergen-specific IgE serological tests are never completely sensitive, nor completely specific. There is only partial correlation between the serum tests and intradermal testing; however, the significance of discrepant results is unknown and unstudied. Variation in test methodologies along with the absence of universal standardization and reporting procedures have created confusion, varying study results, and an inability to compare between studies performed by different investigators.

  9. Evaluation of culture- and PCR-based detection methods for Escherichia coli O157:H7 in inoculated ground beeft.

    PubMed

    Arthur, Terrance M; Bosilevac, Joseph M; Nou, Xiangwu; Koohmaraie, Mohammad

    2005-08-01

    Currently, several beef processors employ test-and-hold systems for increased quality control of ground beef. In such programs, each lot of product must be tested and found negative for Escherichia coli O157:H7 prior to release of the product into commerce. Optimization of three testing attributes (detection time, specificity, and sensitivity) is critical to the success of such strategies. Because ground beef is a highly perishable product, the testing methodology used must be as rapid as possible. The test also must have a low false-positive result rate so product is not needlessly discarded. False-negative results cannot be tolerated because they would allow contaminated product to be released and potentially cause disease. In this study, two culture-based and three PCR-based methods for detecting E. coli O157:H7 in ground beef were compared for their abilities to meet the above criteria. Ground beef samples were individually spiked with five genetically distinct strains of E. coli O157: H7 at concentrations of 17 and 1.7 CFU/65 g and then subjected to the various testing methodologies. There was no difference (P > 0.05) in the abilities of the PCR-based methods to detect E. coli O157:H7 inoculated in ground beef at 1.7 CFU/65 g. The culture-based systems detected more positive samples than did the PCR-based systems, but the detection times (21 to 48 h) were at least 9 h longer than those for the PCR-based methods (7.5 to 12 h). Ground beef samples were also spiked with potentially cross-reactive strains. The PCR-based systems that employed an immunomagnetic separation step prior to detection produced fewer false-positive results.

  10. Impact of an engineering design-based curriculum compared to an inquiry-based curriculum on fifth graders' content learning of simple machines

    NASA Astrophysics Data System (ADS)

    Marulcu, Ismail; Barnett, Michael

    2016-01-01

    Background: Elementary Science Education is struggling with multiple challenges. National and State test results confirm the need for deeper understanding in elementary science education. Moreover, national policy statements and researchers call for increased exposure to engineering and technology in elementary science education. The basic motivation of this study is to suggest a solution to both improving elementary science education and increasing exposure to engineering and technology in it. Purpose/Hypothesis: This mixed-method study examined the impact of an engineering design-based curriculum compared to an inquiry-based curriculum on fifth graders' content learning of simple machines. We hypothesize that the LEGO-engineering design unit is as successful as the inquiry-based unit in terms of students' science content learning of simple machines. Design/Method: We used a mixed-methods approach to investigate our research questions; we compared the control and the experimental groups' scores from the tests and interviews by using Analysis of Covariance (ANCOVA) and compared each group's pre- and post-scores by using paired t-tests. Results: Our findings from the paired t-tests show that both the experimental and comparison groups significantly improved their scores from the pre-test to post-test on the multiple-choice, open-ended, and interview items. Moreover, ANCOVA results show that students in the experimental group, who learned simple machines with the design-based unit, performed significantly better on the interview questions. Conclusions: Our analyses revealed that the design-based Design a people mover: Simple machines unit was, if not better, as successful as the inquiry-based FOSS Levers and pulleys unit in terms of students' science content learning.

  11. Performance-based alternative assessments as a means of eliminating gender achievement differences on science tests

    NASA Astrophysics Data System (ADS)

    Brown, Norman Merrill

    1998-09-01

    Historically, researchers have reported an achievement difference between females and males on standardized science tests. These differences have been reported to be based upon science knowledge, abstract reasoning skills, mathematical abilities, and cultural and social phenomena. This research was designed to determine how mastery of specific science content from public school curricula might be evaluated with performance-based assessment models, without producing gender achievement differences. The assessment instruments used were Harcourt Brace Educational Measurement's GOALSsp°ler: A Performance-Based Measure of Achievement and the performance-based portion of the Stanford Achievement Testspcopyright, Ninth Edition. The identified independent variables were test, gender, ethnicity, and grade level. A 2 x 2 x 6 x 12 (test x gender x ethnicity x grade) factorial experimental design was used to organize the data. A stratified random sample (N = 2400) was selected from a national pool of norming data: N = 1200 from the GOALSsp°ler group and N = 1200 from the SAT9spcopyright group. The ANOVA analysis yielded mixed results. The factors of test, gender, ethnicity by grade, gender by grade, and gender by grade by ethnicity failed to produce significant results (alpha = 0.05). The factors yielding significant results were ethnicity, grade, and ethnicity by grade. Therefore, no significant differences were found between female and male achievement on these performance-based assessments.

  12. Correaltion of full-scale drag predictions with flight measurements on the C-141A aircraft. Phase 2: Wind tunnel test, analysis, and prediction techniques. Volume 1: Drag predictions, wind tunnel data analysis and correlation

    NASA Technical Reports Server (NTRS)

    Macwilkinson, D. G.; Blackerby, W. T.; Paterson, J. H.

    1974-01-01

    The degree of cruise drag correlation on the C-141A aircraft is determined between predictions based on wind tunnel test data, and flight test results. An analysis of wind tunnel tests on a 0.0275 scale model at Reynolds number up to 3.05 x 1 million/MAC is reported. Model support interference corrections are evaluated through a series of tests, and fully corrected model data are analyzed to provide details on model component interference factors. It is shown that predicted minimum profile drag for the complete configuration agrees within 0.75% of flight test data, using a wind tunnel extrapolation method based on flat plate skin friction and component shape factors. An alternative method of extrapolation, based on computed profile drag from a subsonic viscous theory, results in a prediction four percent lower than flight test data.

  13. Evaluation of Machine Learning and Rules-Based Approaches for Predicting Antimicrobial Resistance Profiles in Gram-negative Bacilli from Whole Genome Sequence Data.

    PubMed

    Pesesky, Mitchell W; Hussain, Tahir; Wallace, Meghan; Patel, Sanket; Andleeb, Saadia; Burnham, Carey-Ann D; Dantas, Gautam

    2016-01-01

    The time-to-result for culture-based microorganism recovery and phenotypic antimicrobial susceptibility testing necessitates initial use of empiric (frequently broad-spectrum) antimicrobial therapy. If the empiric therapy is not optimal, this can lead to adverse patient outcomes and contribute to increasing antibiotic resistance in pathogens. New, more rapid technologies are emerging to meet this need. Many of these are based on identifying resistance genes, rather than directly assaying resistance phenotypes, and thus require interpretation to translate the genotype into treatment recommendations. These interpretations, like other parts of clinical diagnostic workflows, are likely to be increasingly automated in the future. We set out to evaluate the two major approaches that could be amenable to automation pipelines: rules-based methods and machine learning methods. The rules-based algorithm makes predictions based upon current, curated knowledge of Enterobacteriaceae resistance genes. The machine-learning algorithm predicts resistance and susceptibility based on a model built from a training set of variably resistant isolates. As our test set, we used whole genome sequence data from 78 clinical Enterobacteriaceae isolates, previously identified to represent a variety of phenotypes, from fully-susceptible to pan-resistant strains for the antibiotics tested. We tested three antibiotic resistance determinant databases for their utility in identifying the complete resistome for each isolate. The predictions of the rules-based and machine learning algorithms for these isolates were compared to results of phenotype-based diagnostics. The rules based and machine-learning predictions achieved agreement with standard-of-care phenotypic diagnostics of 89.0 and 90.3%, respectively, across twelve antibiotic agents from six major antibiotic classes. Several sources of disagreement between the algorithms were identified. Novel variants of known resistance factors and incomplete genome assembly confounded the rules-based algorithm, resulting in predictions based on gene family, rather than on knowledge of the specific variant found. Low-frequency resistance caused errors in the machine-learning algorithm because those genes were not seen or seen infrequently in the test set. We also identified an example of variability in the phenotype-based results that led to disagreement with both genotype-based methods. Genotype-based antimicrobial susceptibility testing shows great promise as a diagnostic tool, and we outline specific research goals to further refine this methodology.

  14. Critical predicted no effect concentrations (PNECs) should not be based on a single toxicity test.

    PubMed

    Chapman, Peter M; Elphick, James R

    2015-05-01

    Predicted no-effect concentrations (PNECs), which represent the concentration of a substance below which an unacceptable effect most likely will not occur, are widely used for risk assessment and in environmental policy and regulation. They are typically based on single-species laboratory toxicity tests; often, a single test result for the most sensitive endpoints drives the derivation of a PNEC. In the present study, the authors provide a case study emphasizing the importance of determining the reliability of those most sensitive endpoints. Five 21-d Daphnia magna toxicity tests conducted using the same procedures by 2 laboratories gave 20% inhibitory concentration responses to a specific ionic composition of total dissolved solids that varied from 684 mg/L to more than 1510 mg/L. The concentration-response curve was shallow; thus, these differences could have been attributable to chance alone. The authors strongly recommend that the most sensitive endpoints that determine PNECs not be based on a single toxicity test result but rather on the geometric mean of at least 3 test results to adequately assess and bound test variability, especially when the concentration-response curve is shallow. © 2015 SETAC.

  15. Development of Standardized Material Testing Protocols for Prosthetic Liners

    PubMed Central

    Cagle, John C.; Reinhall, Per G.; Hafner, Brian J.; Sanders, Joan E.

    2017-01-01

    A set of protocols was created to characterize prosthetic liners across six clinically relevant material properties. Properties included compressive elasticity, shear elasticity, tensile elasticity, volumetric elasticity, coefficient of friction (CoF), and thermal conductivity. Eighteen prosthetic liners representing the diverse range of commercial products were evaluated to create test procedures that maximized repeatability, minimized error, and provided clinically meaningful results. Shear and tensile elasticity test designs were augmented with finite element analysis (FEA) to optimize specimen geometries. Results showed that because of the wide range of available liner products, the compressive elasticity and tensile elasticity tests required two test maxima; samples were tested until they met either a strain-based or a stress-based maximum, whichever was reached first. The shear and tensile elasticity tests required that no cyclic conditioning be conducted because of limited endurance of the mounting adhesive with some liner materials. The coefficient of friction test was based on dynamic coefficient of friction, as it proved to be a more reliable measurement than static coefficient of friction. The volumetric elasticity test required that air be released beneath samples in the test chamber before testing. The thermal conductivity test best reflected the clinical environment when thermal grease was omitted and when liner samples were placed under pressure consistent with load bearing conditions. The developed procedures provide a standardized approach for evaluating liner products in the prosthetics industry. Test results can be used to improve clinical selection of liners for individual patients and guide development of new liner products. PMID:28233885

  16. Comparative effectiveness of incorporating a hypothetical DCIS prognostic marker into breast cancer screening.

    PubMed

    Trentham-Dietz, Amy; Ergun, Mehmet Ali; Alagoz, Oguzhan; Stout, Natasha K; Gangnon, Ronald E; Hampton, John M; Dittus, Kim; James, Ted A; Vacek, Pamela M; Herschorn, Sally D; Burnside, Elizabeth S; Tosteson, Anna N A; Weaver, Donald L; Sprague, Brian L

    2018-02-01

    Due to limitations in the ability to identify non-progressive disease, ductal carcinoma in situ (DCIS) is usually managed similarly to localized invasive breast cancer. We used simulation modeling to evaluate the potential impact of a hypothetical test that identifies non-progressive DCIS. A discrete-event model simulated a cohort of U.S. women undergoing digital screening mammography. All women diagnosed with DCIS underwent the hypothetical DCIS prognostic test. Women with test results indicating progressive DCIS received standard breast cancer treatment and a decrement to quality of life corresponding to the treatment. If the DCIS test indicated non-progressive DCIS, no treatment was received and women continued routine annual surveillance mammography. A range of test performance characteristics and prevalence of non-progressive disease were simulated. Analysis compared discounted quality-adjusted life years (QALYs) and costs for test scenarios to base-case scenarios without the test. Compared to the base case, a perfect prognostic test resulted in a 40% decrease in treatment costs, from $13,321 to $8005 USD per DCIS case. A perfect test produced 0.04 additional QALYs (16 days) for women diagnosed with DCIS, added to the base case of 5.88 QALYs per DCIS case. The results were sensitive to the performance characteristics of the prognostic test, the proportion of DCIS cases that were non-progressive in the model, and the frequency of mammography screening in the population. A prognostic test that identifies non-progressive DCIS would substantially reduce treatment costs but result in only modest improvements in quality of life when averaged over all DCIS cases.

  17. Simulation System of Car Crash Test in C-NCAP Analysis Based on an Improved Apriori Algorithm*

    NASA Astrophysics Data System (ADS)

    Xiang, LI

    In order to analysis car crash test in C-NCAP, an improved algorithm is given based on Apriori algorithm in this paper. The new algorithm is implemented with vertical data layout, breadth first searching, and intersecting. It takes advantage of the efficiency of vertical data layout and intersecting, and prunes candidate frequent item sets like Apriori. Finally, the new algorithm is applied in simulation of car crash test analysis system. The result shows that the relations will affect the C-NCAP test results, and it can provide a reference for the automotive design.

  18. Results of data base management system parameterized performance testing related to GSFC scientific applications

    NASA Technical Reports Server (NTRS)

    Carchedi, C. H.; Gough, T. L.; Huston, H. A.

    1983-01-01

    The results of a variety of tests designed to demonstrate and evaluate the performance of several commercially available data base management system (DBMS) products compatible with the Digital Equipment Corporation VAX 11/780 computer system are summarized. The tests were performed on the INGRES, ORACLE, and SEED DBMS products employing applications that were similar to scientific applications under development by NASA. The objectives of this testing included determining the strength and weaknesses of the candidate systems, performance trade-offs of various design alternatives and the impact of some installation and environmental (computer related) influences.

  19. A Reassessment of Heavy-Duty Truck Aerodynamic Design Features and Priorities

    NASA Technical Reports Server (NTRS)

    Saltzman, Edwin J.; Meyer, Robert R., Jr.

    1999-01-01

    Between 1973 and 1982, the NASA Dryden Flight Research Center conducted "coast-down" tests demonstrating means for reducing the drag of trucks, buses, and motor homes. Numerous configurations were evaluated using a box-shaped test van, a two-axle truck, and a tractor-semitrailer combination. Results from three configurations of the test van are of interest now in view of a trucking industry goal of a 0.25 drag coefficient for tractor-semitrailer combinations. Two test van configurations with blunt-base geometry, similar to present day trucks (one configuration has square front comers and the other has rounded front comers), quantify the base drag increase associated with reduced forebody drag. Hoemer's equations predict this trend; however, test van results, reinforced by large-scale air vehicle data, indicate that Hoemer's formula greatly underestimates this dependence of base drag on forebody efficiency. The demonstrated increase in base drag associated with forebody refinement indicates that the goal of a 0.25 drag coefficient will not be achieved without also reducing afterbody drag. A third configuration of the test van had a truncated boattail to reduce afterbody drag and achieved a drag coefficient of 0.242. These results are included here and references are identified for other means of reducing afterbody drag.

  20. Thermal Expert System (TEXSYS): Systems autonomy demonstration project, volume 2. Results

    NASA Technical Reports Server (NTRS)

    Glass, B. J. (Editor)

    1992-01-01

    The Systems Autonomy Demonstration Project (SADP) produced a knowledge-based real-time control system for control and fault detection, isolation, and recovery (FDIR) of a prototype two-phase Space Station Freedom external active thermal control system (EATCS). The Thermal Expert System (TEXSYS) was demonstrated in recent tests to be capable of reliable fault anticipation and detection, as well as ordinary control of the thermal bus. Performance requirements were addressed by adopting a hierarchical symbolic control approach-layering model-based expert system software on a conventional, numerical data acquisition and control system. The model-based reasoning capabilities of TEXSYS were shown to be advantageous over typical rule-based expert systems, particularly for detection of unforeseen faults and sensor failures. Volume 1 gives a project overview and testing highlights. Volume 2 provides detail on the EATCS testbed, test operations, and online test results. Appendix A is a test archive, while Appendix B is a compendium of design and user manuals for the TEXSYS software.

  1. Thermal Expert System (TEXSYS): Systems autonomy demonstration project, volume 2. Results

    NASA Astrophysics Data System (ADS)

    Glass, B. J.

    1992-10-01

    The Systems Autonomy Demonstration Project (SADP) produced a knowledge-based real-time control system for control and fault detection, isolation, and recovery (FDIR) of a prototype two-phase Space Station Freedom external active thermal control system (EATCS). The Thermal Expert System (TEXSYS) was demonstrated in recent tests to be capable of reliable fault anticipation and detection, as well as ordinary control of the thermal bus. Performance requirements were addressed by adopting a hierarchical symbolic control approach-layering model-based expert system software on a conventional, numerical data acquisition and control system. The model-based reasoning capabilities of TEXSYS were shown to be advantageous over typical rule-based expert systems, particularly for detection of unforeseen faults and sensor failures. Volume 1 gives a project overview and testing highlights. Volume 2 provides detail on the EATCS testbed, test operations, and online test results. Appendix A is a test archive, while Appendix B is a compendium of design and user manuals for the TEXSYS software.

  2. Measurement of susceptibility artifacts with histogram-based reference value on magnetic resonance images according to standard ASTM F2119.

    PubMed

    Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V

    2015-12-01

    The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.

  3. Identification of Anisotropic Criteria for Stratified Soil Based on Triaxial Tests Results

    NASA Astrophysics Data System (ADS)

    Tankiewicz, Matylda; Kawa, Marek

    2017-09-01

    The paper presents the identification methodology of anisotropic criteria based on triaxial test results. The considered material is varved clay - a sedimentary soil occurring in central Poland which is characterized by the so-called "layered microstructure". The strength examination outcomes were identified by standard triaxial tests. The results include the estimated peak strength obtained for a wide range of orientations and confining pressures. Two models were chosen as potentially adequate for the description of the tested material, namely Pariseau and its conjunction with the Jaeger weakness plane. Material constants were obtained by fitting the model to the experimental results. The identification procedure is based on the least squares method. The optimal values of parameters are searched for between specified bounds by sequentially decreasing the distance between points and reducing the length of the searched range. For both considered models the optimal parameters have been obtained. The comparison of theoretical and experimental results as well as the assessment of the suitability of selected criteria for the specified range of confining pressures are presented.

  4. Evaluation of the base/subgrade soil under repeated loading : phase I--laboratory testing and numerical modeling of geogrid reinforced bases in flexible pavement.

    DOT National Transportation Integrated Search

    2009-10-01

    This report documents the results of a study that was conducted to characterize the behavior of geogrid reinforced base : course materials. The research was conducted through an experimental testing and numerical modeling programs. The : experimental...

  5. Effects of computer-based immediate feedback on foreign language listening comprehension and test-associated anxiety.

    PubMed

    Lee, Shu-Ping; Su, Hui-Kai; Lee, Shin-Da

    2012-06-01

    This study investigated the effects of immediate feedback on computer-based foreign language listening comprehension tests and on intrapersonal test-associated anxiety in 72 English major college students at a Taiwanese University. Foreign language listening comprehension of computer-based tests designed by MOODLE, a dynamic e-learning environment, with or without immediate feedback together with the state-trait anxiety inventory (STAI) were tested and repeated after one week. The analysis indicated that immediate feedback during testing caused significantly higher anxiety and resulted in significantly higher listening scores than in the control group, which had no feedback. However, repeated feedback did not affect the test anxiety and listening scores. Computer-based immediate feedback did not lower debilitating effects of anxiety but enhanced students' intrapersonal eustress-like anxiety and probably improved their attention during listening tests. Computer-based tests with immediate feedback might help foreign language learners to increase attention in foreign language listening comprehension.

  6. Web-based versus traditional lecture: are they equally effective as a flexible bronchoscopy teaching method?

    PubMed

    Mata, Caio Augusto Sterse; Ota, Luiz Hirotoshi; Suzuki, Iunis; Telles, Adriana; Miotto, Andre; Leão, Luiz Eduardo Vilaça

    2012-01-01

    This study compares the traditional live lecture to a web-based approach in the teaching of bronchoscopy and evaluates the positive and negative aspects of both methods. We developed a web-based bronchoscopy curriculum, which integrates texts, images and animations. It was applied to first-year interns, who were later administered a multiple-choice test. Another group of eight first-year interns received the traditional teaching method and the same test. The two groups were compared using the Student's t-test. The mean scores (± SD) of students who used the website were 14.63 ± 1.41 (range 13-17). The test scores of the other group had the same range, with a mean score of 14.75 ± 1. The Student's t-test showed no difference between the test results. The common positive point noted was the presence of multimedia content. The web group cited as positive the ability to review the pages, and the other one the role of the teacher. Web-based bronchoscopy education showed results similar to the traditional live lecture in effectiveness.

  7. Home-based versus clinic-based specimen collection in the management of Chlamydia trachomatis and Neisseria gonorrhoeae infections.

    PubMed

    Fajardo-Bernal, Luisa; Aponte-Gonzalez, Johanna; Vigil, Patrick; Angel-Müller, Edith; Rincon, Carlos; Gaitán, Hernando G; Low, Nicola

    2015-09-29

    Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) are the most frequent causes of bacterial sexually transmitted infections (STIs). Management strategies that reduce losses in the clinical pathway from infection to cure might improve STI control and reduce complications resulting from lack of, or inadequate, treatment. To assess the effectiveness and safety of home-based specimen collection as part of the management strategy for Chlamydia trachomatis and Neisseria gonorrhoeae infections compared with clinic-based specimen collection in sexually-active people. We searched the Cochrane Sexually Transmitted Infections Group Specialized Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE and LILACS on 27 May 2015, together with the World Health Organization International Clinical Trials Registry (ICTRP) and ClinicalTrials.gov. We also handsearched conference proceedings, contacted trial authors and reviewed the reference lists of retrieved studies. Randomized controlled trials (RCTs) of home-based compared with clinic-based specimen collection in the management of C. trachomatis and N. gonorrhoeae infections. Three review authors independently assessed trials for inclusion, extracted data and assessed risk of bias. We contacted study authors for additional information. We resolved any disagreements through consensus. We used standard methodological procedures recommended by Cochrane. The primary outcome was index case management, defined as the number of participants tested, diagnosed and treated, if test positive. Ten trials involving 10,479 participants were included. There was inconclusive evidence of an effect on the proportion of participants with index case management (defined as individuals tested, diagnosed and treated for CT or NG, or both) in the group with home-based (45/778, 5.8%) compared with clinic-based (51/788, 6.5%) specimen collection (risk ratio (RR) 0.88, 95% confidence interval (CI) 0.60 to 1.29; 3 trials, I² = 0%, 1566 participants, moderate quality). Harms of home-based specimen collection were not evaluated in any trial. All 10 trials compared the proportions of individuals tested. The results for the proportion of participants completing testing had high heterogeneity (I² = 100%) and were not pooled. We could not combine data from individual studies looking at the number of participants tested because the proportions varied widely across the studies, ranging from 30% to 96% in home group and 6% to 97% in clinic group (low-quality evidence). The number of participants with positive test was lower in the home-based specimen collection group (240/2074, 11.6%) compared with the clinic-based group (179/967, 18.5%) (RR 0.72, 95% CI 0.61 to 0.86; 9 trials, I² = 0%, 3041 participants, moderate quality). Home-based specimen collection could result in similar levels of index case management for CT or NG infection when compared with clinic-based specimen collection. Increases in the proportion of individuals tested as a result of home-based, compared with clinic-based, specimen collection are offset by a lower proportion of positive results. The harms of home-based specimen collection compared with clinic-based specimen collection have not been evaluated. Future RCTs to assess the effectiveness of home-based specimen collection should be designed to measure biological outcomes of STI case management, such as proportion of participants with negative tests for the relevant STI at follow-up.

  8. Multiaxial Fatigue Life Prediction Based on Nonlinear Continuum Damage Mechanics and Critical Plane Method

    NASA Astrophysics Data System (ADS)

    Wu, Z. R.; Li, X.; Fang, L.; Song, Y. D.

    2018-04-01

    A new multiaxial fatigue life prediction model has been proposed in this paper. The concepts of nonlinear continuum damage mechanics and critical plane criteria were incorporated in the proposed model. The shear strain-based damage control parameter was chosen to account for multiaxial fatigue damage under constant amplitude loading. Fatigue tests were conducted on nickel-based superalloy GH4169 tubular specimens at the temperature of 400 °C under proportional and nonproportional loading. The proposed method was checked against the multiaxial fatigue test data of GH4169. Most of prediction results are within a factor of two scatter band of the test results.

  9. Intelligent Evaluation Method of Tank Bottom Corrosion Status Based on Improved BP Artificial Neural Network

    NASA Astrophysics Data System (ADS)

    Qiu, Feng; Dai, Guang; Zhang, Ying

    According to the acoustic emission information and the appearance inspection information of tank bottom online testing, the external factors associated with tank bottom corrosion status are confirmed. Applying artificial neural network intelligent evaluation method, three tank bottom corrosion status evaluation models based on appearance inspection information, acoustic emission information, and online testing information are established. Comparing with the result of acoustic emission online testing through the evaluation of test sample, the accuracy of the evaluation model based on online testing information is 94 %. The evaluation model can evaluate tank bottom corrosion accurately and realize acoustic emission online testing intelligent evaluation of tank bottom.

  10. Testing primates with joystick-based automated apparatus - Lessons from the Language Research Center's Computerized Test System

    NASA Technical Reports Server (NTRS)

    Washburn, David A.; Rumbaugh, Duane M.

    1992-01-01

    Nonhuman primates provide useful models for studying a variety of medical, biological, and behavioral topics. Four years of joystick-based automated testing of monkeys using the Language Research Center's Computerized Test System (LRC-CTS) are examined to derive hints and principles for comparable testing with other species - including humans. The results of multiple parametric studies are reviewed, and reliability data are presented to reveal the surprises and pitfalls associated with video-task testing of performance.

  11. Evaluation of the CDC proposed laboratory HIV testing algorithm among men who have sex with men (MSM) from five US metropolitan statistical areas using specimens collected in 2011.

    PubMed

    Masciotra, Silvina; Smith, Amanda J; Youngpairoj, Ae S; Sprinkle, Patrick; Miles, Isa; Sionean, Catlainn; Paz-Bailey, Gabriela; Johnson, Jeffrey A; Owen, S Michele

    2013-12-01

    Until recently most testing algorithms in the United States (US) utilized Western blot (WB) as the supplemental test. CDC has proposed an algorithm for HIV diagnosis which includes an initial screen with a Combo Antigen/Antibody 4th generation-immunoassay (IA), followed by an HIV-1/2 discriminatory IA of initially reactive-IA specimens. Discordant results in the proposed algorithm are resolved by nucleic acid-amplification testing (NAAT). Evaluate the results obtained with the CDC proposed laboratory-based algorithm using specimens from men who have sex with men (MSM) obtained in five metropolitan statistical areas (MSAs). Specimens from 992 MSM from five MSAs participating in the CDC's National HIV Behavioral Surveillance System in 2011 were tested at local facilities and CDC. The five MSAs utilized algorithms of various screening assays and specimen types, and WB as the supplemental test. At the CDC, serum/plasma specimens were screened with 4th generation-IA and the Multispot HIV-1/HIV-2 discriminatory assay was used as the supplemental test. NAAT was used to resolve discordant results and to further identify acute HIV infections from all screened-non-reactive missed by the proposed algorithm. Performance of the proposed algorithm was compared to site-specific WB-based algorithms. The proposed algorithm detected 254 infections. The WB-based algorithms detected 19 fewer infections; 4 by oral fluid (OF) rapid testing and 15 by WB supplemental testing (12 OF and 3 blood). One acute infection was identified by NAAT from all screened-non-reactive specimens. The proposed algorithm identified more infections than the WB-based algorithms in a high-risk MSM population. OF testing was associated with most of the discordant results between algorithms. HIV testing with the proposed algorithm can increase diagnosis of infected individuals, including early infections. Published by Elsevier B.V.

  12. Optimization and large scale computation of an entropy-based moment closure

    NASA Astrophysics Data System (ADS)

    Kristopher Garrett, C.; Hauck, Cory; Hill, Judith

    2015-12-01

    We present computational advances and results in the implementation of an entropy-based moment closure, MN, in the context of linear kinetic equations, with an emphasis on heterogeneous and large-scale computing platforms. Entropy-based closures are known in several cases to yield more accurate results than closures based on standard spectral approximations, such as PN, but the computational cost is generally much higher and often prohibitive. Several optimizations are introduced to improve the performance of entropy-based algorithms over previous implementations. These optimizations include the use of GPU acceleration and the exploitation of the mathematical properties of spherical harmonics, which are used as test functions in the moment formulation. To test the emerging high-performance computing paradigm of communication bound simulations, we present timing results at the largest computational scales currently available. These results show, in particular, load balancing issues in scaling the MN algorithm that do not appear for the PN algorithm. We also observe that in weak scaling tests, the ratio in time to solution of MN to PN decreases.

  13. Optimization and large scale computation of an entropy-based moment closure

    DOE PAGES

    Hauck, Cory D.; Hill, Judith C.; Garrett, C. Kristopher

    2015-09-10

    We present computational advances and results in the implementation of an entropy-based moment closure, M N, in the context of linear kinetic equations, with an emphasis on heterogeneous and large-scale computing platforms. Entropy-based closures are known in several cases to yield more accurate results than closures based on standard spectral approximations, such as P N, but the computational cost is generally much higher and often prohibitive. Several optimizations are introduced to improve the performance of entropy-based algorithms over previous implementations. These optimizations include the use of GPU acceleration and the exploitation of the mathematical properties of spherical harmonics, which aremore » used as test functions in the moment formulation. To test the emerging high-performance computing paradigm of communication bound simulations, we present timing results at the largest computational scales currently available. Lastly, these results show, in particular, load balancing issues in scaling the M N algorithm that do not appear for the P N algorithm. We also observe that in weak scaling tests, the ratio in time to solution of M N to P N decreases.« less

  14. Subsonic stability and control flight test results of the Space Shuttle /tail cone off/

    NASA Technical Reports Server (NTRS)

    Cooke, D. R.

    1980-01-01

    The subsonic stability and control testing of the Space Shuttle Orbiter in its two test flights in the tailcone-off configuration is discussed, and test results are presented. Flight test maneuvers were designed to maximize the quality and quantity of stability and control data in the minimal time allotted using the Space Shuttle Functional Simulator and the Modified Maximum Likelihood Estimator (MMLE) programs, and coefficients were determined from standard sensor data sets using the MMLE, despite problems encountered in timing due to the different measurement systems used. Results are included for lateral directional and longitudinal maneuvers as well as the Space Shuttle aerodynamic data base obtained using the results of wind tunnel tests. The flight test data are found to permit greater confidence in the data base since the differences found are well within control system capability. It is suggested that the areas of major differences, including lateral directional data with open speedbrake, roll due to rudder and normal force due to elevon, be investigated in any further subsonic flight testing. Improvements in sensor data and data handling techniques for future orbital test flights are indicated.

  15. 37: COMPARISON OF TWO METHODS: TBL-BASED AND LECTURE-BASED LEARNING IN NURSING CARE OF PATIENTS WITH DIABETES IN NURSING STUDENTS

    PubMed Central

    Khodaveisi, Masoud; Qaderian, Khosro; Oshvandi, Khodayar; Soltanian, Ali Reza; Vardanjani, Mehdi molavi

    2017-01-01

    Background and aims learning plays an important role in developing nursing skills and right care-taking. The Present study aims to evaluate two learning methods based on team –based learning and lecture-based learning in learning care-taking of patients with diabetes in nursing students. Method In this quasi-experimental study, 64 students in term 4 in nursing college of Bukan and Miandoab were included in the study based on knowledge and performance questionnaire including 15 questions based on knowledge and 5 questions based on performance on care-taking in patients with diabetes were used as data collection tool whose reliability was confirmed by cronbach alpha (r=0.83) by the researcher. To compare the mean score of knowledge and performance in each group in pre-test step and post-test step, pair –t test and to compare mean of scores in two groups of control and intervention, the independent t- test was used. Results There was not significant statistical difference between two groups in pre terms of knowledge and performance score (p=0.784). There was significant difference between the mean of knowledge scores and diabetes performance in the post-test in the team-based learning group and lecture-based learning group (p=0.001). There was significant difference between the mean score of knowledge of diabetes care in pre-test and post-test in base learning groups (p=0.001). Conclusion In both methods team-based and lecture-based learning approaches resulted in improvement in learning in students, but the rate of learning in the team-based learning approach is greater compared to that of lecture-based learning and it is recommended that this method be used as a higher education method in the education of students.

  16. In Vitro Comparison of Cytotoxicity of Four Root Canal Sealers on Human Gingival Fibroblasts

    PubMed Central

    Konjhodzic-Prcic, Alma; Gorduysus, Omer; Kucukkaya, Selen; Atila, Burcu; Muftuoglu, Sevda; Zeybek, Dilara

    2015-01-01

    The goal of this in vitro study was to evaluate the relative biocompatibility of four endodontic sealers on the cell culture of the human fibroblast through cytotoxicity. Materials and Methods: In this study four endodontics sealers was used GuttaFlow (Roeko)silicone based sealer, AH plus (De Tray-DENTSPLY) epoxy resin based, Apexit (Vivadent) calcium hydroxide based and Endorez (Ultradent) methacrylate based sealer. Sealers were tested on primary cell lines of human gingival fibroblasts. Experiments were preformed in laboratories of Hacettepe University of Ankara, Turkey and Faculty of Dentistry, University of Sarajevo, Bosnia and Herzegovina Cytotoxicity was determinate using WST-1 assay. Results: Results were analyzed by SPSS 19 program. Kolgomorov-Smirnov test, Shapiro-Wilk and descriptive statistics also were used, as well as Kriskall-Wallis, ANOVA test and T- test. According to our results all four sealers showed different cytotoxicity effects on human gingival fibroblast cell culture, but all of them are slightly cytotoxic. Conclusions: According to results of this study it can be concluded: all four sealers showed different cytotoxicity effects on primary cell lines of human gingival fibroblasts, but all of them are slightly cytotoxicity. PMID:25870472

  17. Development of Cold-Formed Steel Seismic Design Recommendations

    DTIC Science & Technology

    2015-08-01

    applied loads, so the impact on design would be minimal. However, had the test been carried out to larger panel deformations without loss of capacity... test shear panels and development of preliminary design recommendations 6. Definition of material properties and coupon test results 7. Pretest of...predicted panel response based on preliminary design model and coupon test results 8. Definition of test configuration, procedures, and

  18. Automation and results of Adjacent Band Emission testing

    DOT National Transportation Integrated Search

    2015-03-01

    Problem Statement : Multiple groups conduct tests in various ways - Outcomes vary based on test setup and assumptions - No standard has been established to conduct such tests - Spectrum is scarce and the need for compliance testing will only increase...

  19. In Silico Testing of an Artificial-Intelligence-Based Artificial Pancreas Designed for Use in the Intensive Care Unit Setting.

    PubMed

    DeJournett, Leon; DeJournett, Jeremy

    2016-11-01

    Effective glucose control in the intensive care unit (ICU) setting has the potential to decrease morbidity and mortality rates which should in turn lead to decreased health care expenditures. Current ICU-based glucose controllers are mathematically derived, and tend to be based on proportional integral derivative (PID) or model predictive control (MPC). Artificial intelligence (AI)-based closed loop glucose controllers may have the ability to achieve control that improves on the results achieved by either PID or MPC controllers. We conducted an in silico analysis of an AI-based glucose controller designed for use in the ICU setting. This controller was tested using a mathematical model of the ICU patient's glucose-insulin system. A total of 126 000 unique 5-day simulations were carried out, resulting in 107 million glucose values for analysis. For the 7 control ranges tested, with a sensor error of ±10%, the following average results were achieved: (1) time in control range, 94.2%, (2) time in range 70-140 mg/dl, 97.8%, (3) time in hyperglycemic range (>140 mg/dl), 2.1%, and (4) time in hypoglycemic range (<70 mg/dl), 0.09%. In addition, the average coefficient of variation (CV) was 11.1%. This in silico study of an AI-based closed loop glucose controller shows that it may be able to improve on the results achieved by currently existing ICU-based PID/MPC controllers. If these results are confirmed in clinical testing, this AI-based controller could be used to create an artificial pancreas system for use in the ICU setting. © 2016 Diabetes Technology Society.

  20. Lactose (mal)digestion evaluated by the 13C-lactose digestion test.

    PubMed

    Vonk, R J; Lin, Y; Koetse, H A; Huang, C; Zeng, G; Elzinga, H; Antoine, J; Stellaard, F

    2000-02-01

    The prevalence of genetically determined lactase nonpersistence is based on the results of the lactose H2 breath test. This test, however, is an indirect test, which might lead to misinterpretation. We determined lactase activity in healthy Chinese and Dutch students using a novel 13C-lactose digestion test. The cut-off value of this test was established in a Chinese population with a homogenous genetic background of lactase nonpersistence and was compared with the results obtained in a Caucasian population. Twenty-five grams of a 13C-lactose solution was consumed by 12 known H2-positive and 5 H2-negative Chinese students and 48 Dutch students and, subsequently, 13C-glucose concentration in plasma and H2 excretion in breath were measured. A similar 13C-glucose response curve was found in all Chinese students. The mean response curve in the Dutch students was more pronounced (P < 0.01). The 1 h (peak) plasma 13C-glucose concentration was the best discriminator between lactose digesting and maldigesting subjects. The cut-off level of 2 mmol L-1 13C-glucose in plasma was defined in the H2-positive Chinese students group. Based on the 13C-glucose response the prevalence of lactose maldigestion in the Dutch subjects was 25%; based on the lactose H2 breath test 17%. Using the 13C-lactose digestion test the results demonstrate a higher prevalence of lactose maldigestion in a Caucasian population than indicated by the results of the H2 breath test. A moderate increase in the plasma 13C-glucose concentration after consumption of 13C-lactose in the young adult Chinese subjects indicates a residual lactase activity in that age group, even when a positive H2 breath test result is obtained. These results indicate that the 13C-glucose concentration in plasma more accurately reflects the small intestinal lactose digestion capacity than the lactose H2 breath test.

  1. Test Use and Abuse

    ERIC Educational Resources Information Center

    Tienken, Christopher H.

    2015-01-01

    The ubiquitous use of standardized test results to make varied judgments about educators, students, and schools within the public school system raises concerns of validity. If the test results have not been validated for making multiple determinations, then the decisions made about educators, students, schools, and school districts based on the…

  2. Different Results of IgE Binding- and Crosslinking-Based Allergy Tests Caused by Allergen Immobilization.

    PubMed

    Okamoto-Uchida, Yoshimi; Nakamura, Ryosuke; Matsuzawa, Yumiko; Soma, Megumi; Kawakami, Hiroshi; Ishii-Watabe, Akiko; Nishimaki-Mogami, Tomoko; Teshima, Reiko; Saito, Yoshiro

    2016-01-01

    The physicochemical nature of allergen molecules differ from the liquid phase to the solid phase. However, conventional allergy tests are based on the detection of immunoglobulin (Ig)E binding to immobilized allergens. We recently developed an in vitro allergy testing method using a luciferase-reporting humanized rat mast cell line to detect IgE crosslinking-induced luciferase expression (EXiLE test). The aim of the present study was to evaluate the effects of antigen immobilization on the results of different in vitro allergy tests using two anti-ovalbumin (OVA) antibodies (Abs), E-C1 and E-G5, with different properties in the OVA-induced allergic reaction. Both Abs showed clear binding to OVA with an enzyme-linked immunosorbent assay and by BIAcore analysis. However, only E-C1 potentiated EXiLE response for the liquid-phase OVA. On the other hand, OVA immobilized on solid-phase induced EXiLE responses in both E-C1 Ab- and E-G5 Ab-sensitized mast cells. Western blotting of OVA indicated that E-C1 Ab binds both to OVA monomers and dimers, unlike E-G5 Ab, which probably binds only to the OVA dimer. These results suggest that antigen immobilization enhanced IgE crosslinking ability through multimerization of allergen molecules in the solid phase, resulting in an increase in false positives in IgE binding-based conventional in vitro allergy tests. These findings shed light on the physicochemical nature of antigens as an important factor for the development and evaluation of in vitro allergy tests and suggest that mast cell activation-based allergy testing with liquid-phase allergens is a promising strategy to evaluate the physiological interactions of IgE and allergens.

  3. Guidelines for Proof Test Analysis

    NASA Technical Reports Server (NTRS)

    Chell, G. G.; McClung, R. C.; Kuhlman, C. J.; Russell, D. A.; Garr, K.; Donnelly, B.

    1999-01-01

    These guidelines integrate state-of-the-art elastic-plastic fracture mechanics (EPFM) and proof test implementation issues into a comprehensive proof test analysis procedure in the form of a road map which identifies the types of data, fracture mechanics based parameters, and calculations needed to perform flaw screening and minimum proof load analyses of fracture critical components. Worked examples are presented to illustrate the application of the road map to proof test analysis. The state-of-the art fracture technology employed in these guidelines is based on the EPFM parameter, J, and a pictorial representation of a J fracture analysis, called the failure assessment diagram (FAD) approach. The recommended fracture technology is validated using finite element J results, and laboratory and hardware fracture test results on the nickel-based superalloy Inconel 718, the aluminum alloy 2024-T3511, and ferritic pressure vessel steels. In all cases the laboratory specimens and hardware failed by ductile mechanisms. Advanced proof test analyses involving probability analysis and multiple-cycle proof testing (MCPT) are addressed. Finally, recommendations are provided on how to account for the effects of the proof test overload on subsequent service fatigue and fracture behaviors.

  4. Feasibility of supervised self-testing using an oral fluid-based HIV rapid testing method: a cross-sectional, mixed method study among pregnant women in rural India

    PubMed Central

    Sarkar, Archana; Mburu, Gitau; Shivkumar, Poonam Varma; Sharma, Pankhuri; Campbell, Fiona; Behera, Jagannath; Dargan, Ritu; Mishra, Surendra Kumar; Mehra, Sunil

    2016-01-01

    Introduction HIV self-testing can increase coverage of essential HIV services. This study aimed to establish the acceptability, concordance and feasibility of supervised HIV self-testing among pregnant women in rural India. Methods A cross-sectional, mixed methods study was conducted among 202 consenting pregnant women in a rural Indian hospital between August 2014 and January 2015. Participants were provided with instructions on how to self-test using OraQuick® HIV antibody test, and subsequently asked to self-test under supervision of a community health worker. Test results were confirmed at a government-run integrated counselling and testing centre. A questionnaire was used to obtain information on patient demographics and the ease, acceptability and difficulties of self-testing. In-depth interviews were conducted with a sub-sample of 35 participants to understand their experiences. Results In total, 202 participants performed the non-invasive, oral fluid-based, rapid test under supervision for HIV screening. Acceptance rate was 100%. Motivators for self-testing included: ease of testing (43.4%), quick results (27.3%) and non-invasive procedure (23.2%). Sensitivity and specificity were 100% for 201 tests, and one test was invalid. Concordance of test result interpretation between community health workers and participants was 98.5% with a Cohen's Kappa (k) value of k=0.566 with p<0.001 for inter-rater agreement. Although 92.6% participants reported that the instructions for the test were easy to understand, 18.7% required the assistance of a supervisor to self-test. Major themes that emerged from the qualitative interviews indicated the importance of the following factors in influencing acceptability of self-testing: clarity and accessibility of test instructions; time-efficiency and convenience of testing; non-invasiveness of the test; and fear of incorrect results. Overall, 96.5% of the participants recommended that the OraQuick® test kits should become publicly available. Conclusions Self-testing for HIV status using an oral fluid-based rapid test under the supervision of a community health worker was acceptable and feasible among pregnant women in rural India. Participants were supportive of making self-testing publicly available. Policy guidelines and implementation research are required to advance HIV self-testing for larger populations at scale. PMID:27630096

  5. Impact of reference change value (RCV) based autoverification on turnaround time and physician satisfaction

    PubMed Central

    Fernández-Grande, Esther; Valera-Rodriguez, Carolina; Sáenz-Mateos, Luis; Sastre-Gómez, Amparo; García-Chico, Pilar; Palomino-Muñoz, Teodoro J.

    2017-01-01

    Background For a quicker delivery of laboratory test results to the hospital emergency department (ED), we implemented an autoverification system based on the reference change value (RCV). The aim of this study was to assess how the RCV based autoverification reflected on turnaround time (TAT) and on physician satisfaction. Materials and methods The laboratory information system (LIS) was programmed to autoverify the results as long as they were within the range settled by RCV, so that the autoverified results were reported to the physician as soon as the tests were carried out, without any further intervention. We analyzed the same three-month periods’ TAT and verification time (VFT) from the years prior to and following the implementation of RCV autoverification. The change in physicians’ satisfaction levels was assessed using the hospital’s Annual Physician Satisfaction Survey (APSS). Over sixty percent of physicians completed the questionnaire, and the amount of daily ED test requests (nearly three hundred) did not vary throughout the duration of this study. Results Mann-Whitney U test showed that the VFT was significantly reduced in all the test but troponin I. There were substantial reductions in TAT medians (haemogram, 75%; fibrinogen, 41%; prothrombin time, 40%; sodium, 27%). The percentage of physicians satisfied with the haematological and biochemical tests´ TAT increased from 84% to 93% and from 86% to 91% respectively. Conclusions Our results reveal that VFT and TAT were severely reduced in most emergency tests, greatly improving physicians’ satisfaction with TAT. PMID:28694725

  6. Integration of genomic medicine into pathology residency training: the stanford open curriculum.

    PubMed

    Schrijver, Iris; Natkunam, Yasodha; Galli, Stephen; Boyd, Scott D

    2013-03-01

    Next-generation sequencing methods provide an opportunity for molecular pathology laboratories to perform genomic testing that is far more comprehensive than single-gene analyses. Genome-based test results are expected to develop into an integral component of diagnostic clinical medicine and to provide the basis for individually tailored health care. To achieve these goals, rigorous interpretation of high-quality data must be informed by the medical history and the phenotype of the patient. The discipline of pathology is well positioned to implement genome-based testing and to interpret its results, but new knowledge and skills must be included in the training of pathologists to develop expertise in this area. Pathology residents should be trained in emerging technologies to integrate genomic test results appropriately with more traditional testing, to accelerate clinical studies using genomic data, and to help develop appropriate standards of data quality and evidence-based interpretation of these test results. We have created a genomic pathology curriculum as a first step in helping pathology residents build a foundation for the understanding of genomic medicine and its implications for clinical practice. This curriculum is freely accessible online. Copyright © 2013 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  7. Are Participants in a Street-Based HIV Testing Program Able to Perform Their Own Rapid Test and Interpret the Results?

    PubMed Central

    de la Fuente, Luis; Rosales-Statkus, María Elena; Hoyos, Juan; Pulido, José; Santos, Sara; Bravo, María José; Barrio, Gregorio; Fernández-Balbuena, Sonia; Belza, María José

    2012-01-01

    Objective Availability of over-the-counter rapid HIV tests could improve access to testing those reluctant or unable to use current services. We aimed to evaluate the feasibility of HIV self-testing using a finger-stick whole-blood rapid test (Determine™ HIV Combo) to detect both antigen and antibody. Methods Before being tested, 313 participants in a street-based testing program were given adapted instructions and a test kit, and performed the self-test without supervision. These participants, together with another 207 who performed supervised self-testing, received additional instructions on how to interpret the test results shown in six colour photos and filled out a questionnaire. Logistic regression and generalized estimating equations (GEE) were used in the statistical analysis. Results About 8.0% (95%CI:4.8%–11.2%) obtained an invalid self-test. An invalid result was inversely associated with male participants who had sex with men (OR = 0.3;95%CI:0.1–1.0). Of the 3111 photos interpreted,4.9% (95%CI:4.1–5.7) were incorrect. Only 1.1% (95%CI:0.3–1.8) of the positive results were interpreted as negative. Age 30 or older (OR = 2.1; 95%CI:1.2–3.7), having been born in Latin America (OR = 1.6; 95%CI:1.1–2.2),and not having university education (OR = 2.1;95%CI:1.2–3.7) were associated with misinterpreting test results in the GEE. Participant's perceptions of both their proficiency when conducting the test and interpretation were related with actual outcomes. Most participants (83.9%) were more motivated than before to use the self-test in the future, and 51.7% would pay >10 Euros for the test if it was sold in pharmacies. Conclusions This is the first study showing that blood-based self-testing with current technology is feasible in HIV-negative participants demanding the test and without prior training or supervision. Bearing in mind that it was conducted under difficult weather conditions and using a complex kit, over-the-counter tests could be a feasible option to complement current diagnostic strategies. More studies are needed to accommodate technology, minimise interpretation mistakes and provide on-line support. PMID:23056342

  8. Effect of the yeast and bacteria biomass on the microbiota in the rumen.

    PubMed

    Vamanu, E; Vamanu, A; Popa, O; Vassu, Tatiana; Ghindea, Raluca; Pelinescu, Diana; Nita, Sultana; Babeanu, Narcisa

    2008-09-15

    This study aims at obtaining a probiotic product based on viable biomass from 6 yeast strains and 2 strains of lactic bacteria used for nutrition of animals. The strains are subjected to some resistance tests, at temperature, pH, pepsin, pancreatin and biliary salts so as to make obvious their viability. Tests were done by comparison to the witness strain and respectively a protective solution based on mucin and casein. Based on the resulted viabilities 2 products are formulated. Their effect is tested by inoculating fresh rumen content and supervising the microbic balance for a period of 12 days. After the final tests, it resulted that the product Fpl (20% Saccharomyces cerevisiae 1-29, 10% Kluyveromyces marxianus R-CS, 20% Issatchenkia orientalis R-BC, 30% Lactobacillus paracasei CMGB16, 20% Enterococcus faecium GM8) was chosen because anaerobic strains were preponderant as a consequence of the tests performed with rumen.

  9. Offgassing Characterization of the Columbus Laboratory Module

    NASA Technical Reports Server (NTRS)

    Rampini, riccardo; Lobascio, Cesare; Perry, Jay L.; Hinderer, Stephan

    2005-01-01

    Trace gaseous contamination in the cabin environment is a major concern for manned spacecraft, especially those designed for long duration missions, such as the International Space Station (ISS). During the design phase, predicting the European-built Columbus laboratory module s contribution to the ISS s overall trace contaminant load relied on "trace gas budgeting" based on material level and assembled article tests data. In support of the Qualification Review, a final offgassing test has been performed on the complete Columbus module to gain cumulative system offgassing data. Comparison between the results of the predicted offgassing load based on the budgeted material/assembled article-level offgassing rates and the module-level offgassing test is presented. The Columbus module offgassing test results are also compared to results from similar tests conducted for Node 1, U.S. Laboratory, and Airlock modules.

  10. Validity evidence for the situational judgment test paradigm in emotional intelligence measurement.

    PubMed

    Libbrecht, Nele; Lievens, Filip

    2012-01-01

    To date, various measurement approaches have been proposed to assess emotional intelligence (EI). Recently, two new EI tests have been developed based on the situational judgment test (SJT) paradigm: the Situational Test of Emotional Understanding (STEU) and the Situational Test of Emotion Management (STEM). Initial attempts have been made to examine the construct-related validity of these new tests; we extend these findings by placing the tests in a broad nomological network. To this end, 850 undergraduate students completed a personality inventory, a cognitive ability test, a self-report EI test, a performance-based EI measure, the STEU, and the STEM. The SJT-based EI tests were not strongly correlated with personality and fluid cognitive ability. Regarding their relation with existing EI measures, the tests did not capture the same construct as self-report EI measures, but corresponded rather to performance-based EI measures. Overall, these results lend support for the SJT paradigm for measuring EI as an ability.

  11. Development of hybrid electric vehicle powertrain test system based on virtue instrument

    NASA Astrophysics Data System (ADS)

    Xu, Yanmin; Guo, Konghui; Chen, Liming

    2017-05-01

    Hybrid powertrain has become the standard configuration of some automobile models. The test system of hybrid vehicle powertrain was developed based on virtual instrument, using electric dynamometer to simulate the work of engines, to test the motor and control unit of the powertrain. The test conditions include starting, acceleration, and deceleration. The results show that the test system can simulate the working conditions of the hybrid electric vehicle powertrain under various conditions.

  12. Development of a sensitive and specific indirect enzyme-linked immunosorbent assay based on a baculovirus recombinant antigen for detection of specific antibodies against Ehrlichia canis.

    PubMed

    López, Lissett; Venteo, Angel; Aguirre, Enara; García, Marga; Rodríguez, Majosé; Amusátegui, Inmaculada; Tesouro, Miguel A; Vela, Carmen; Sainz, Angel; Rueda, Paloma

    2007-11-01

    An indirect enzyme-linked immunosorbent assay (ELISA) based on baculovirus recombinant P30 protein of Ehrlichia canis and the 1BH4 anticanine IgG monoclonal antibody was developed and evaluated by examining a panel of 98 positive and 157 negative sera using the indirect fluorescent antibody (IFA) test as the reference technique. The P30-based ELISA appeared to be sensitive and specific (77.55% and 95.54%, respectively) when qualitative results (positive/negative) were compared with those of the IFA test; the coefficient of correlation (R) between the 2 tests was 0.833. Furthermore, it was possible to establish a mathematical formula for use in comparing the results of both techniques. These results indicate that recombinant P30 antigen-based ELISA is a suitable alternative of the IFA test for simple, consistent, and rapid serodiagnosis of canine ehrlichiosis. Moreover, the use of this recombinant protein as antigen offers a great advantage for antigen preparation in comparison with other techniques in which the whole E. canis organism is used as antigen.

  13. Experimental rotordynamic coefficient results for honeycomb seals

    NASA Technical Reports Server (NTRS)

    Elrod, David A.; Childs, Dara W.

    1988-01-01

    Test results (leakage and rotordynamic coefficients) are presented for seven honeycomb-stator smooth-rotor seals. Tests were carried out with air at rotor speeds up to 16,000 cpm and supply pressures up to 8.2 bars. Test results for the seven seals are compared, and the most stable configuration is identified based on the whirl frequency ratio. Results from tests of a smooth-rotor/smooth-stator seal, a teeth-on-stator labyrinth seal, and the most stable honeycomb seal are compared.

  14. A study on nonlinear estimation of submaximal effort tolerance based on the generalized MET concept and the 6MWT in pulmonary rehabilitation

    PubMed Central

    Szczegielniak, Jan; Łuniewski, Jacek; Stanisławski, Rafał; Bogacz, Katarzyna; Krajczy, Marcin; Rydel, Marek

    2018-01-01

    Background The six-minute walk test (6MWT) is considered to be a simple and inexpensive tool for the assessment of functional tolerance of submaximal effort. The aim of this work was 1) to background the nonlinear nature of the energy expenditure process due to physical activity, 2) to compare the results/scores of the submaximal treadmill exercise test and those of 6MWT in pulmonary patients and 3) to develop nonlinear mathematical models relating the two. Methods The study group included patients with the COPD. All patients were subjected to a submaximal exercise test and a 6MWT. To develop an optimal mathematical solution and compare the results of the exercise test and the 6MWT, the least squares and genetic algorithms were employed to estimate parameters of polynomial expansion and piecewise linear models. Results Mathematical analysis enabled to construct nonlinear models for estimating the MET result of submaximal exercise test based on average walk velocity (or distance) in the 6MWT. Conclusions Submaximal effort tolerance in COPD patients can be effectively estimated from new, rehabilitation-oriented, nonlinear models based on the generalized MET concept and the 6MWT. PMID:29425213

  15. Comparing the results of an analytical model of the no-vent fill process with no-vent fill test results for a 4.96 cubic meters (175 cubic feet) tank

    NASA Technical Reports Server (NTRS)

    Taylor, William J.; Chato, David J.

    1993-01-01

    The NASA Lewis Research Center (NASA/LeRC) have been investigating a no-vent fill method for refilling cryogenic storage tanks in low gravity. Analytical modeling based on analyzing the heat transfer of a droplet has successfully represented the process in 0.034 m and 0.142 cubic m commercial dewars using liquid nitrogen and hydrogen. Recently a large tank (4.96 cubic m) was tested with hydrogen. This lightweight tank is representative of spacecraft construction. This paper presents efforts to model the large tank test data. The droplet heat transfer model is found to over predict the tank pressure level when compared to the large tank data. A new model based on equilibrium thermodynamics has been formulated. This new model is compared to the published large scale tank's test results as well as some additional test runs with the same equipment. The results are shown to match the test results within the measurement uncertainty of the test data except for the initial transient wall cooldown where it is conservative (i.e., overpredicts the initial pressure spike found in this time frame).

  16. Near-Threshold Fatigue Crack Growth Behavior of Fine-Grain Nickel-Based Alloys

    NASA Technical Reports Server (NTRS)

    Newman, John A.; Piascik, Robert S.

    2003-01-01

    Constant-Kmax fatigue crack growth tests were performed on two finegrain nickel-base alloys Inconel 718 (DA) and Ren 95 to determine if these alloys exhibit near-threshold time-dependent crack growth behavior observed for fine-grain aluminum alloys in room-temperature laboratory air. Test results showed that increases in K(sub max) values resulted in increased crack growth rates, but no evidence of time-dependent crack growth was observed for either nickel-base alloy at room temperature.

  17. Perceptions and performance using computer-based testing: One institution's experience.

    PubMed

    Bloom, Timothy J; Rich, Wesley D; Olson, Stephanie M; Adams, Michael L

    2018-02-01

    The purpose of this study was to evaluate student and faculty perceptions of the transition to a required computer-based testing format and to identify any impact of this transition on student exam performance. Separate questionnaires sent to students and faculty asked about perceptions of and problems with computer-based testing. Exam results from program-required courses for two years prior to and two years following the adoption of computer-based testing were compared to determine if this testing format impacted student performance. Responses to Likert-type questions about perceived ease of use showed no difference between students with one and three semesters experience with computer-based testing. Of 223 student-reported problems, 23% related to faculty training with the testing software. Students most commonly reported improved feedback (46% of responses) and ease of exam-taking (17% of responses) as benefits to computer-based testing. Faculty-reported difficulties were most commonly related to problems with student computers during an exam (38% of responses) while the most commonly identified benefit was collecting assessment data (32% of responses). Neither faculty nor students perceived an impact on exam performance due to computer-based testing. An analysis of exam grades confirmed there was no consistent performance difference between the paper and computer-based formats. Both faculty and students rapidly adapted to using computer-based testing. There was no evidence that switching to computer-based testing had any impact on student exam performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Verification of an Automated, Digital Dispensing Platform for At-Will Broth Microdilution-Based Antimicrobial Susceptibility Testing.

    PubMed

    Smith, Kenneth P; Kirby, James E

    2016-09-01

    With rapid emergence of multidrug-resistant bacteria, there is often a need to perform susceptibility testing for less commonly used or newer antimicrobial agents. Such testing can often be performed only by using labor-intensive, manual dilution methods and lies outside the capacity of most clinical labs, necessitating reference laboratory testing and thereby delaying the availability of susceptibility data. To address the compelling clinical need for microbiology laboratories to perform such testing in-house, we explored a novel, automated, at-will broth microdilution-based susceptibility testing platform. Specifically, we used the modified inkjet printer technology in the HP D300 digital dispensing system to dispense, directly from stock solutions into a 384-well plate, the 2-fold serial dilution series required for broth microdilution testing. This technology was combined with automated absorbance readings and data analysis to determine MICs. Performance was verified by testing members of the Enterobacteriaceae for susceptibility to ampicillin, cefazolin, ciprofloxacin, colistin, gentamicin, meropenem, and tetracycline in comparison to the results obtained with a broth microdilution reference standard. In precision studies, essential and categorical agreement levels were 96.8% and 98.3%, respectively. Furthermore, significantly fewer D300-based measurements were outside ±1 dilution from the modal MIC, suggesting enhanced reproducibility. In accuracy studies performed using a panel of 80 curated clinical isolates, rates of essential and categorical agreement and very major, major, and minor errors were 94%, 96.6%, 0%, 0%, and 3.4%, respectively. Based on these promising initial results, it is anticipated that the D300-based methodology will enable hospital-based clinical microbiology laboratories to perform at-will broth microdilution testing of antimicrobials and to address a critical testing gap. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  19. Multidimensional Test Assembly Based on Lagrangian Relaxation Techniques. Research Report 98-08.

    ERIC Educational Resources Information Center

    Veldkamp, Bernard P.

    In this paper, a mathematical programming approach is presented for the assembly of ability tests measuring multiple traits. The values of the variance functions of the estimators of the traits are minimized, while test specifications are met. The approach is based on Lagrangian relaxation techniques and provides good results for the two…

  20. Story Based Activities Enhance Literacy Skills in Preschool Children

    ERIC Educational Resources Information Center

    Yazici, Elçin; Bolay, Hayrunnisa

    2017-01-01

    We investigated the impact of story-based activities on literacy skills in pre-school children. The efficacy of story-based activities program were tested by literacy skills survey test. Results showed that, the scores of overall literacy skills and all subsets skills in the study group (n = 45) were statistically significantly higher than the…

  1. Assessing Computer Literacy: A Validated Instrument and Empirical Results.

    ERIC Educational Resources Information Center

    Gabriel, Roy M.

    1985-01-01

    Describes development of a comprehensive computer literacy assessment battery for K-12 curriculum based on objectives of a curriculum implemented in the Worldwide Department of Defense Dependents Schools system. Test development and field test data are discussed and a correlational analysis which assists in interpretation of test results is…

  2. Experimental BCAS Performance Results

    DOT National Transportation Integrated Search

    1978-07-01

    The results of the (Litchford) Beacon-based Collision Avoidance System concept feasibility evaluation are reported. Included are a description of the concept, analysis and flight test results. The system concept is based on the range and bearing meas...

  3. Tuberculin Skin Tests versus Interferon-Gamma Release Assays in Tuberculosis Screening among Immigrant Visa Applicants

    PubMed Central

    Chuke, Stella O.; Yen, Nguyen Thi Ngoc; Laserson, Kayla F.; Phuoc, Nguyen Huu; Trinh, Nguyen An; Nhung, Duong Thi Cam; Mai, Vo Thi Chi; Qui, An Dang; Hai, Hoang Hoa; Loan, Le Thien Huong; Jones, Warren G.; Whitworth, William C.; Shah, J. Jina; Painter, John A.; Mazurek, Gerald H.; Maloney, Susan A.

    2014-01-01

    Objective. Use of tuberculin skin tests (TSTs) and interferon gamma release assays (IGRAs) as part of tuberculosis (TB) screening among immigrants from high TB-burden countries has not been fully evaluated. Methods. Prevalence of Mycobacterium tuberculosis infection (MTBI) based on TST, or the QuantiFERON-TB Gold test (QFT-G), was determined among immigrant applicants in Vietnam bound for the United States (US); factors associated with test results and discordance were assessed; predictive values of TST and QFT-G for identifying chest radiographs (CXRs) consistent with TB were calculated. Results. Of 1,246 immigrant visa applicants studied, 57.9% were TST positive, 28.3% were QFT-G positive, and test agreement was 59.4%. Increasing age was associated with positive TST results, positive QFT-G results, TST-positive but QFT-G-negative discordance, and abnormal CXRs consistent with TB. Positive predictive values of TST and QFT-G for an abnormal CXR were 25.9% and 25.6%, respectively. Conclusion. The estimated prevalence of MTBI among US-bound visa applicants in Vietnam based on TST was twice that based on QFT-G, and 14 times higher than a TST-based estimate of MTBI prevalence reported for the general US population in 2000. QFT-G was not better than TST at predicting abnormal CXRs consistent with TB. PMID:24738031

  4. Prefabricated Roof Beams for Hardened Shelters

    DTIC Science & Technology

    1993-08-01

    beam with a composite concrete slab. Based on the results of the concept evaluation, a test program was designed and conducted to validate the steel...ultimaw, strength. The results of these tests showed that the design procedure accurately predicts the response of the ste,-confined concrete composite...BENDING OF EXTERNALLY REINFORCED CONCRETE BEAMS ........ 67 TABLE 9. SINGLE POINT LOAD BEAM TEST RESULTS

  5. Cost-effectiveness of MODY genetic testing: translating genomic advances into practical health applications.

    PubMed

    Naylor, Rochelle N; John, Priya M; Winn, Aaron N; Carmody, David; Greeley, Siri Atma W; Philipson, Louis H; Bell, Graeme I; Huang, Elbert S

    2014-01-01

    OBJECTIVE To evaluate the cost-effectiveness of a genetic testing policy for HNF1A-, HNF4A-, and GCK-MODY in a hypothetical cohort of type 2 diabetic patients 25-40 years old with a MODY prevalence of 2%. RESEARCH DESIGN AND METHODS We used a simulation model of type 2 diabetes complications based on UK Prospective Diabetes Study data, modified to account for the natural history of disease by genetic subtype to compare a policy of genetic testing at diabetes diagnosis versus a policy of no testing. Under the screening policy, successful sulfonylurea treatment of HNF1A-MODY and HNF4A-MODY was modeled to produce a glycosylated hemoglobin reduction of -1.5% compared with usual care. GCK-MODY received no therapy. Main outcome measures were costs and quality-adjusted life years (QALYs) based on lifetime risk of complications and treatments, expressed as the incremental cost-effectiveness ratio (ICER) (USD/QALY). RESULTS The testing policy yielded an average gain of 0.012 QALYs and resulted in an ICER of 205,000 USD. Sensitivity analysis showed that if the MODY prevalence was 6%, the ICER would be ~50,000 USD. If MODY prevalence was >30%, the testing policy was cost saving. Reducing genetic testing costs to 700 USD also resulted in an ICER of ~50,000 USD. CONCLUSIONS Our simulated model suggests that a policy of testing for MODY in selected populations is cost-effective for the U.S. based on contemporary ICER thresholds. Higher prevalence of MODY in the tested population or decreased testing costs would enhance cost-effectiveness. Our results make a compelling argument for routine coverage of genetic testing in patients with high clinical suspicion of MODY.

  6. Transonic wind tunnel tests of a .015 scale space shuttle booster model

    NASA Technical Reports Server (NTRS)

    Dennis, R. J.

    1972-01-01

    Details of the test program, an outline of the test procedure, and results of the investigation in tabular form are presented. The base drag reduction potential was determined at cruise conditions (M = .40) of a modified base region, with and without base bleed flow. Transonic effects and cruise control effectiveness of the new base region were also obtained. The tests were performed at Mach numbers from 0.40 to 1.10, at angles of attack from -4 to +20 degrees and at angles of sideslip from -6 to +6 degrees, all at a Reynolds number of 6.56 million per meter (2.0 million per foot).

  7. A systematic review of randomized trials assessing human papillomavirus testing in cervical cancer screening

    PubMed Central

    Patanwala, Insiyyah Y.; Bauer, Heidi M.; Miyamoto, Justin; Park, Ina U.; Huchko, Megan J.; Smith-McCune, Karen K.

    2013-01-01

    Our objective was to assess the sensitivity and specificity of human papillomavirus (HPV) testing for cervical cancer screening in randomized trials. We conducted a systematic literature search of the following databases: MEDLINE, CINAHL, EMBASE, and Cochrane. Eligible studies were randomized trials comparing HPV-based to cytology-based screening strategies, with disease status determined by colposcopy/biopsy for participants with positive results. Disease rates (cervical intraepithelial neoplasia [CIN]2 or greater and CIN3 or greater), sensitivity, and positive predictive value were abstracted or calculated from the articles. Six studies met inclusion criteria. Relative sensitivities for detecting CIN3 or greater of HPV testing-based strategies vs cytology ranged from 0.8 to 2.1. The main limitation of our study was that testing methodologies and screening/management protocols were highly variable across studies. Screening strategies in which a single initial HPV-positive test led to colposcopy were more sensitive than cytology but resulted in higher colposcopy rates. These results have implications for cotesting with HPV and cytology as recommended in the United States. PMID:23159693

  8. Evaluation of Lightning Induced Effects in a Graphite Composite Fairing Structure. Parts 1 and 2

    NASA Technical Reports Server (NTRS)

    Trout, Dawn H.; Stanley, James E.; Wahid, Parveen F.

    2011-01-01

    Defining the electromagnetic environment inside a graphite composite fairing due to lightning is of interest to spacecraft developers. This paper is the first in a two part series and studies the shielding effectiveness of a graphite composite model fairing using derived equivalent properties. A frequency domain Method of Moments (MoM) model is developed and comparisons are made with shielding test results obtained using a vehicle-like composite fairing. The comparison results show that the analytical models can adequately predict the test results. Both measured and model data indicate that graphite composite fairings provide significant attenuation to magnetic fields as frequency increases. Diffusion effects are also discussed. Part 2 examines the time domain based effects through the development of a loop based induced field testing and a Transmission-Line-Matrix (TLM) model is developed in the time domain to study how the composite fairing affects lightning induced magnetic fields. Comparisons are made with shielding test results obtained using a vehicle-like composite fairing in the time domain. The comparison results show that the analytical models can adequately predict the test and industry results.

  9. SU-E-T-769: T-Test Based Prior Error Estimate and Stopping Criterion for Monte Carlo Dose Calculation in Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong, X; Gao, H; Schuemann, J

    2015-06-15

    Purpose: The Monte Carlo (MC) method is a gold standard for dose calculation in radiotherapy. However, it is not a priori clear how many particles need to be simulated to achieve a given dose accuracy. Prior error estimate and stopping criterion are not well established for MC. This work aims to fill this gap. Methods: Due to the statistical nature of MC, our approach is based on one-sample t-test. We design the prior error estimate method based on the t-test, and then use this t-test based error estimate for developing a simulation stopping criterion. The three major components are asmore » follows.First, the source particles are randomized in energy, space and angle, so that the dose deposition from a particle to the voxel is independent and identically distributed (i.i.d.).Second, a sample under consideration in the t-test is the mean value of dose deposition to the voxel by sufficiently large number of source particles. Then according to central limit theorem, the sample as the mean value of i.i.d. variables is normally distributed with the expectation equal to the true deposited dose.Third, the t-test is performed with the null hypothesis that the difference between sample expectation (the same as true deposited dose) and on-the-fly calculated mean sample dose from MC is larger than a given error threshold, in addition to which users have the freedom to specify confidence probability and region of interest in the t-test based stopping criterion. Results: The method is validated for proton dose calculation. The difference between the MC Result based on the t-test prior error estimate and the statistical Result by repeating numerous MC simulations is within 1%. Conclusion: The t-test based prior error estimate and stopping criterion are developed for MC and validated for proton dose calculation. Xiang Hong and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)« less

  10. Model-Based Development of Automotive Electronic Climate Control Software

    NASA Astrophysics Data System (ADS)

    Kakade, Rupesh; Murugesan, Mohan; Perugu, Bhupal; Nair, Mohanan

    With increasing complexity of software in today's products, writing and maintaining thousands of lines of code is a tedious task. Instead, an alternative methodology must be employed. Model-based development is one candidate that offers several benefits and allows engineers to focus on the domain of their expertise than writing huge codes. In this paper, we discuss the application of model-based development to the electronic climate control software of vehicles. The back-to-back testing approach is presented that ensures flawless and smooth transition from legacy designs to the model-based development. Simulink report generator to create design documents from the models is presented along with its usage to run the simulation model and capture the results into the test report. Test automation using model-based development tool that support the use of unique set of test cases for several testing levels and the test procedure that is independent of software and hardware platform is also presented.

  11. A modified culture-based study of bacterial community composition in a tannery wastewater treatment plant.

    PubMed

    Desta, Adey F; Dalhammer, Gunnel; Kittuva, Gunatrana R

    2010-01-01

    Though culture-independent methods have been used in preference to traditional isolation techniques for characterization of microbial community of wastewater treatment plants, it is difficult to widely apply this approach in resource-poor countries. The present study aimed to develop a test to identify the culturable portion of bacterial community in a high-strength wastewater. Wastewater samples were collected from nitrification-denitrification and settling tanks of the treatment plant of Elmo Leather AB tannery located in Borås, Sweden. After cultivating on nutrient agar with the optimal dilution (10⁻²), phenotypic and biochemical identification of the bacteria were done with colony morphology, Gram reaction, growth on MacConkey, phenylethanol media, triple sugar Iron agar slants, catalase and oxidase tests. Biochemical grouping of the isolates was done based on their test results for MacConkey, phenylethanol media, triple sugar Iron agar and oxidase test reaction. From the biochemical groups, isolates were randomly selected for API test and 16SrRNA gene sequencing. The isolates from the denitrification, nitrification tank were identified to be Paracoccus denitrificans (67%), Azoarcus spp (3%) and Spingomonas wittichii (1%). From the settling tank, Paracoccus denitrificans (22%), Corynebacterium freneyi (20%) and Bacillus cereus (1%) were identified. The grouping based on biochemical test results as well as the identification based on sequencing has shown coherence except for discrepancies with the API test. The preliminary implications of the grouping based on culture-based characteristics and its potential application for resource-limited environmental microbial studies is discussed.

  12. High-resolution image reconstruction technique applied to the optical testing of ground-based astronomical telescopes

    NASA Astrophysics Data System (ADS)

    Jin, Zhenyu; Lin, Jing; Liu, Zhong

    2008-07-01

    By study of the classical testing techniques (such as Shack-Hartmann Wave-front Sensor) adopted in testing the aberration of ground-based astronomical optical telescopes, we bring forward two testing methods on the foundation of high-resolution image reconstruction technology. One is based on the averaged short-exposure OTF and the other is based on the Speckle Interferometric OTF by Antoine Labeyrie. Researches made by J.Ohtsubo, F. Roddier, Richard Barakat and J.-Y. ZHANG indicated that the SITF statistical results would be affected by the telescope optical aberrations, which means the SITF statistical results is a function of optical system aberration and the atmospheric Fried parameter (seeing). Telescope diffraction-limited information can be got through two statistics methods of abundant speckle images: by the first method, we can extract the low frequency information such as the full width at half maximum (FWHM) of the telescope PSF to estimate the optical quality; by the second method, we can get a more precise description of the telescope PSF with high frequency information. We will apply the two testing methods to the 2.4m optical telescope of the GMG Observatory, in china to validate their repeatability and correctness and compare the testing results with that of the Shack-Hartmann Wave-Front Sensor got. This part will be described in detail in our paper.

  13. Screening women for cervical cancer carcinoma with a HPV mRNA test: first results from the Venice pilot program.

    PubMed

    Maggino, Tiziano; Sciarrone, Rocco; Murer, Bruno; Dei Rossi, Maria Rosa; Fedato, Chiara; Maran, Michela; Lorio, Melania; Soldà, Marika; Zago, Fiorella; Giorgi Rossi, Paolo; Zorzi, Manuel

    2016-08-23

    HPV DNA-based screening is more effective than a Pap test in preventing cervical cancer, but the test is less specific. New HPV tests have been proposed for primary screening. The HPV mRNA test showed a similar or slightly lower sensitivity than the HPV DNA tests but with a higher specificity. We report the results of an organised HPV mRNA-based screening pilot program in Venice, Italy. From October 2011 to May 2014, women aged 25-64 years were invited to undergo a HPV mRNA test (Aptima). Those testing positive underwent cytological triage. Women with positive cytology were referred to colposcopy, whereas those with negative cytology were referred to repeat the HPV mRNA test 1 year later. The results of the HPV mRNA test program were compared with both the local historical cytology-based program and with four neighbouring DNA HPV-based pilot projects. Overall, 23 211 women underwent a HPV mRNA test. The age-standardised positivity rate was 7.0%, higher than in HPV DNA programs (6.8%; relative rate (RR) 1.11, 95% confidence interval (CI) 1.05-1.17). The total colposcopy referral was 5.1%, double than with cytology (2.6%; RR 2.02, 95% CI 1.82-2.25) but similar to the HPV DNA programs (4.8%; RR 1.02; 95% CI 0.96-1.08). The cervical intraepithelial neoplasia grade 2+ detection rate with HPV mRNA was greater than in the HPV DNA programs at baseline (RR 1.50; 95% CI 1.19-1.88) and not significantly lower at the 1-year repeat (RR 0.70; 95% CI 0.40-1.16). The overall RR was 1.29 (95% CI 1.05-1.59), which was much higher than with cytology (detection rate 5.5‰ vs 2.1‰; RR 2.50, 95% CI 1.76-3.62). A screening programme based on the HPV mRNA obtained results similar to those observed with the HPV DNA test. In routine screening programmes, even a limited increase in HPV prevalence may conceal the advantage represented by the higher specificity of HPV mRNA.

  14. Novel Image Encryption Scheme Based on Chebyshev Polynomial and Duffing Map

    PubMed Central

    2014-01-01

    We present a novel image encryption algorithm using Chebyshev polynomial based on permutation and substitution and Duffing map based on substitution. Comprehensive security analysis has been performed on the designed scheme using key space analysis, visual testing, histogram analysis, information entropy calculation, correlation coefficient analysis, differential analysis, key sensitivity test, and speed test. The study demonstrates that the proposed image encryption algorithm shows advantages of more than 10113 key space and desirable level of security based on the good statistical results and theoretical arguments. PMID:25143970

  15. Design and Development of a Rapid Research, Design, and Development Platform for In-Situ Testing of Tools and Concepts for Trajectory-Based Operations

    NASA Technical Reports Server (NTRS)

    Underwood, Matthew C.

    2017-01-01

    To provide justification for equipping a fleet of aircraft with avionics capable of supporting trajectory-based operations, significant flight testing must be accomplished. However, equipping aircraft with these avionics and enabling technologies to communicate the clearances required for trajectory-based operations is cost-challenging using conventional avionics approaches. This paper describes an approach to minimize the costs and risks of flight testing these technologies in-situ, discusses the test-bed platform developed, and highlights results from a proof-of-concept flight test campaign that demonstrates the feasibility and efficiency of this approach.

  16. The Cost-effectiveness of Rapid HIV Testing in Substance Abuse Treatment: Results of a Randomized Trial*

    PubMed Central

    Schackman, Bruce R.; Metsch, Lisa R.; Colfax, Grant N.; Leff, Jared A.; Wong, Angela; Scott, Callie A.; Feaster, Daniel J.; Gooden, Lauren; Matheson, Tim; Haynes, Louise F.; Paltiel, A. David; Walensky, Rochelle P.

    2012-01-01

    BACKGROUND The President’s National HIV/AIDS Strategy calls for coupling HIV screening and prevention services with substance abuse treatment programs. Fewer than half of US community-based substance abuse treatment programs make HIV testing available on-site or through referral. METHODS We measured the cost-effectiveness of three HIV testing strategies evaluated in a randomized trial conducted in 12 community-based substance abuse treatment programs in 2009: off-site testing referral, on-site rapid testing with information only, on-site rapid testing with risk reduction counseling. Data from the trial included patient demographics, prior testing history, test acceptance and receipt of results, undiagnosed HIV prevalence (0.4%) and program costs. The Cost Effectiveness of Preventing AIDS Complications (CEPAC) computer simulation model was used to project life expectancy, lifetime costs, and quality-adjusted life years (QALYs) for HIV-infected individuals. Incremental cost-effectiveness ratios (2009 US $/QALY) were calculated after adding costs of testing HIV-uninfected individuals; costs and QALYs were discounted at 3% annually. RESULTS Referral for off-site testing is less efficient (dominated) compared to offering on-site testing with information only. The cost-effectiveness ratio for on-site testing with information is $60,300/QALY in the base case, or $76,300/QALY with 0.1% undiagnosed HIV prevalence. HIV risk-reduction counseling costs $36 per person more without additional benefit. CONCLUSIONS A strategy of on-site rapid HIV testing offer with information only in substance abuse treatment programs increases life expectancy at a cost-effectiveness ratio <$100,000/QALY. Policymakers and substance abuse treatment leaders should seek funding to implement on-site rapid HIV testing in substance abuse treatment programs for those not recently tested. PMID:22971593

  17. Creep rupture testing of alloy 617 and A508/533 base metals and weldments.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Natesan, K.; Li, M.; Soppet, W.K.

    2012-01-17

    The NGNP, which is an advanced HTGR concept with emphasis on both electricity and hydrogen production, involves helium as the coolant and a closed-cycle gas turbine for power generation with a core outlet/gas turbine inlet temperature of 750-1000 C. Alloy 617 is a prime candidate for VHTR structural components such as reactor internals, piping, and heat exchangers in view of its resistance to oxidation and elevated temperature strength. However, lack of adequate data on the performance of the alloy in welded condition prompted to initiate a creep test program at Argonne National Laboratory. In addition, Testing has been initiated tomore » evaluate the creep rupture properties of the pressure vessel steel A508/533 in air and in helium environments. The program, which began in December 2009, was certified for quality assurance NQA-1 requirements during January and February 2010. Specimens were designed and fabricated during March and the tests were initiated in April 2010. During the past year, several creep tests were conducted in air on Alloy 617 base metal and weldment specimens at temperatures of 750, 850, and 950 C. Idaho National Laboratory, using gas tungsten arc welding method with Alloy 617 weld wire, fabricated the weldment specimens. Eight tests were conducted on Alloy 617 base metal specimens and nine were on Alloy 617 weldments. The creep rupture times for the base alloy and weldment tests were up to {approx}3900 and {approx}4500 h, respectively. The results showed that the creep rupture lives of weld specimens are much longer than those for the base alloy, when tested under identical test conditions. The test results also showed that the creep strain at fracture is in the range of 7-18% for weldment samples and were much lower than those for the base alloy, under similar test conditions. In general, the weldment specimens showed more of a flat or constant creep rate region than the base metal specimens. The base alloy and the weldment exhibited tertiary creep after 50-60% of the rupture life, irrespective of test temperature in the range of 750-950 C. The results showed that the stress dependence of the creep rate followed a power law for both base alloy and weldments. The data also showed that the stress exponent for creep is the same and one can infer that the same mechanism is operative in both base metal and weldments in the temperature range of the current study. SEM fractography analysis indicated that both base metal and weldment showed combined fracture modes consisting of dimple rupture and intergranular cracking. Intergranular cracking was more evident in the weldment specimens, which is consistent with the observation of lower creep ductility in the weldment than in the base metal.« less

  18. Experimental Evaluation of Suitability of Selected Multi-Criteria Decision-Making Methods for Large-Scale Agent-Based Simulations.

    PubMed

    Tučník, Petr; Bureš, Vladimír

    2016-01-01

    Multi-criteria decision-making (MCDM) can be formally implemented by various methods. This study compares suitability of four selected MCDM methods, namely WPM, TOPSIS, VIKOR, and PROMETHEE, for future applications in agent-based computational economic (ACE) models of larger scale (i.e., over 10 000 agents in one geographical region). These four MCDM methods were selected according to their appropriateness for computational processing in ACE applications. Tests of the selected methods were conducted on four hardware configurations. For each method, 100 tests were performed, which represented one testing iteration. With four testing iterations conducted on each hardware setting and separated testing of all configurations with the-server parameter de/activated, altogether, 12800 data points were collected and consequently analyzed. An illustrational decision-making scenario was used which allows the mutual comparison of all of the selected decision making methods. Our test results suggest that although all methods are convenient and can be used in practice, the VIKOR method accomplished the tests with the best results and thus can be recommended as the most suitable for simulations of large-scale agent-based models.

  19. Comparison of Several Methods of Predicting the Pressure Loss at Altitude Across a Baffled Aircraft-Engine Cylinder

    NASA Technical Reports Server (NTRS)

    Neustein, Joseph; Schafer, Louis J , Jr

    1946-01-01

    Several methods of predicting the compressible-flow pressure loss across a baffled aircraft-engine cylinder were analytically related and were experimentally investigated on a typical air-cooled aircraft-engine cylinder. Tests with and without heat transfer covered a wide range of cooling-air flows and simulated altitudes from sea level to 40,000 feet. Both the analysis and the test results showed that the method based on the density determined by the static pressure and the stagnation temperature at the baffle exit gave results comparable with those obtained from methods derived by one-dimensional-flow theory. The method based on a characteristic Mach number, although related analytically to one-dimensional-flow theory, was found impractical in the present tests because of the difficulty encountered in defining the proper characteristic state of the cooling air. Accurate predictions of altitude pressure loss can apparently be made by these methods, provided that they are based on the results of sea-level tests with heat transfer.

  20. Concurrence of rule- and similarity-based mechanisms in artificial grammar learning.

    PubMed

    Opitz, Bertram; Hofmann, Juliane

    2015-03-01

    A current theoretical debate regards whether rule-based or similarity-based learning prevails during artificial grammar learning (AGL). Although the majority of findings are consistent with a similarity-based account of AGL it has been argued that these results were obtained only after limited exposure to study exemplars, and performance on subsequent grammaticality judgment tests has often been barely above chance level. In three experiments the conditions were investigated under which rule- and similarity-based learning could be applied. Participants were exposed to exemplars of an artificial grammar under different (implicit and explicit) learning instructions. The analysis of receiver operating characteristics (ROC) during a final grammaticality judgment test revealed that explicit but not implicit learning led to rule knowledge. It also demonstrated that this knowledge base is built up gradually while similarity knowledge governed the initial state of learning. Together these results indicate that rule- and similarity-based mechanisms concur during AGL. Moreover, it could be speculated that two different rule processes might operate in parallel; bottom-up learning via gradual rule extraction and top-down learning via rule testing. Crucially, the latter is facilitated by performance feedback that encourages explicit hypothesis testing. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Development and testing of incident detection algorithms. Vol. 2, research methodology and detailed results.

    DOT National Transportation Integrated Search

    1976-04-01

    The development and testing of incident detection algorithms was based on Los Angeles and Minneapolis freeway surveillance data. Algorithms considered were based on times series and pattern recognition techniques. Attention was given to the effects o...

  2. Resilient moduli of typical Missouri soils and unbound granular base materials

    DOT National Transportation Integrated Search

    2008-03-01

    The objective of this project is to accurately determine the resilient moduli for common Missouri subgrade soils and unbound granular base materials in accordance with the AASHTO T 307 test method. The test results included moduli data from 27 common...

  3. Integrated vehicle-based safety systems : heavy-truck field operational test key findings report.

    DOT National Transportation Integrated Search

    2010-08-01

    This document presents key findings from the heavy-truck field operational test conducted as : part of the Integrated Vehicle-Based Safety Systems program. These findings are the result of : analyses performed by the University of Michigan Transporta...

  4. Integrated vehicle-based safety systems light-vehicle field operational test key findings report.

    DOT National Transportation Integrated Search

    2011-01-01

    This document presents key findings from the light-vehicle field operational test conducted as part of the Integrated Vehicle-Based Safety Systems program. These findings are the result of analyses performed by the University of Michigan Transportati...

  5. Integrated vehicle-based safety systems light-vehicle field operational test key findings report.

    DOT National Transportation Integrated Search

    2011-01-01

    "This document presents key findings from the light-vehicle field operational test conducted as part of the Integrated Vehicle-Based Safety Systems program. These findings are the result of analyses performed by the University of Michigan Transportat...

  6. User manual for the NTS ground motion data base retrieval program: ntsgm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    App, F.N.; Tunnell, T.W.

    1994-05-01

    The NTS (Nevada Test Site) Ground Motion Data Base is composed of strong motion data recorded during the normal execution of the US underground test program. It contains surface, subsurface, and structure motion data as digitized waveforms. Currently the data base contains information from 148 underground explosions. This represents about 4,200 measurements and nearly 12,000 individual digitized waveforms. Most of the data was acquired by Los Alamos National Laboratory (LANL) in connection with LANL sponsored underground tests. Some was acquired by Los Alamos on tests conducted by the Defense Nuclear Agency (DNA) and Lawrence Livermore National Laboratory (LLNL), and theremore » are some measurements that were acquired by the other test sponsors on their events and provided for inclusion in this data base. Data acquisition, creation of the data base, and development of the data base retrieval program (ntsgm) are the result of work in support of the Los Alamos Field Test Office and the Office of Nonproliferation and Arms Control.« less

  7. Disposable cartridge biosensor platform for portable diagnostics

    NASA Astrophysics Data System (ADS)

    Yaras, Yusuf S.; Cakmak, Onur; Gunduz, Ali B.; Saglam, Gokhan; Olcer, Selim; Mostafazadeh, Aref; Baris, Ibrahim; Civitci, Fehmi; Yaralioglu, Goksen G.; Urey, Hakan

    2017-03-01

    We developed two types of cantilever-based biosensors for portable diagnostics applications. One sensor is based on MEMS cantilever chip mounted in a microfluidic channel and the other sensor is based on a movable optical fiber placed across a microfluidic channel. Both types of sensors were aimed at direct mechanical measurement of coagulation time in a disposable cartridge using plasma or whole blood samples. There are several similarities and also some important differences between the MEMS based and the optical fiber based solutions. The aim of this paper is to provide a comparison between the two solutions and the results. For both types of sensors, actuation of the cantilever or the moving fiber is achieved using an electro coil and the readout is optical. Since both the actuation and sensing are remote, no electrical connections are required for the cartridge. Therefore it is possible to build low cost disposable cartridges. The reader unit for the cartridge contains light sources, photodetectors, the electro coil, a heater, analog electronics, and a microprocessor. The reader unit has different optical interfaces for the cartridges that have MEMS cantilevers and moving fibers. MEMS based platform has better sensitivity but optomechanical alignment is a challenge and measurements with whole blood were not possible due to high scattering of light by the red blood cells. Fiber sensor based platform has relaxed optomechanical tolerances, ease of manufacturing, and it allows measurements in whole blood. Both sensors were tested using control plasma samples for activated-Partial-Thromboplastin-Time (aPTT) measurements. Control plasma test results matched with the manufacturer's datasheet. Optical fiber based system was tested for aPTT tests with human whole blood samples and the proposed platform provided repeatable test results making the system method of choice for portable diagnostics.

  8. Safety and efficacy of a non-pesticide-based head lice treatment: results of a randomised comparative trial in children.

    PubMed

    Greive, Kerryn A; Lui, Ada H; Barnes, Tanya M; Oppenheim, V M Jane

    2012-11-01

    Increasing resistance to pesticide-based head lice treatments has resulted in the need for alternative products to treat head lice infestations, but there are few clinical studies that have adequately tested these products. This multicentre, randomised, assessor-blind, parallel-group phase IV trial compared the safety and efficacy of a non-pesticide-based head lice shampoo with malathion foam in children. This trial used strict entry criteria, standardised treatment and assessment regimes, sibling control and a primary efficacy end-point defined as the absence of live head lice 21 days after initiating treatment. Repeat insult patch tests were performed to further assess the safety of the non-pesticide-based shampoo. In vitro tests were used to assess its ovicidal and pediculicidal efficacy. A total of 216 children were enrolled, of whom 172 were per-protocol. The non-pesticide-based shampoo was significantly more effective than malathion foam for the intent-to-treat population (62.3 vs 40.4% louse-free, unadjusted P = 0.002; adjusted P = 0.003), as well as for the per-protocol population (67.8 vs 43.0% louse-free, unadjusted P = 0.001; adjusted P = 0.004). Adverse events were limited to itching or stinging. Patch testing with the non-pesticide-based shampoo resulted in no adverse reactions. In vitro tests using body lice demonstrated that the non-pesticide-based shampoo is ovicidal and pediculicidal. The non-pesticide-based shampoo is significantly more effective in eliminating head lice than malathion foam in children, while being associated with a low incidence of mild, transient adverse events. © 2012 Ego Pharmaceuticals Pty Ltd Australasian Journal of Dermatology © 2012 The Australasian College of Dermatologists.

  9. Direct structural parameter identification by modal test results

    NASA Technical Reports Server (NTRS)

    Chen, J.-C.; Kuo, C.-P.; Garba, J. A.

    1983-01-01

    A direct identification procedure is proposed to obtain the mass and stiffness matrices based on the test measured eigenvalues and eigenvectors. The method is based on the theory of matrix perturbation in which the correct mass and stiffness matrices are expanded in terms of analytical values plus a modification matrix. The simplicity of the procedure enables real time operation during the structural testing.

  10. Use of tablet-based kiosks in the emergency department to guide patient HIV self-testing with a point-of-care oral fluid test.

    PubMed

    Gaydos, Charlotte A; Solis, Melissa; Hsieh, Yu-Hsiang; Jett-Goheen, Mary; Nour, Samah; Rothman, Richard E

    2013-09-01

    Despite successes in efforts to integrate HIV testing into routine care in emergency departments, challenges remain. Kiosk-facilitated, directed HIV self-testing offers one novel approach to address logistical challenges. Emergency department patients, 18-64 years, were recruited to evaluate use of tablet-based-kiosks to guide patients to conduct their own point-of-care HIV tests followed by standard-of-care HIV tests by healthcare workers. Both tests were OraQuick Advance tests. Of 955 patients approached, 473 (49.5%) consented; 467 completed the test, and 100% had concordant results with healthcare workers. Median age was 41 years, 59.6% were female, 74.8% were African-American, and 19.6% were White. In all, 99.8% of patients believed the self-test was "definitely" or "probably" correct; 91.7% of patients "trusted their results very much"; 99.8% reported "overall" self-testing was "easy or somewhat easy" to perform. Further, 96.9% indicated they would "probably" or "definitely" test themselves at home were the HIV test available for purchase; 25.9% preferred self-testing versus 34.4% who preferred healthcare professional testing (p>0.05). Tablet-based kiosk testing proved to be highly feasible, acceptable, and an accurate method of conducting rapid HIV self-testing in this study; however, rates of engagement were moderate. More research will be required to ascertain barriers to increased engagement for self-testing.

  11. Design and Development Computer-Based E-Learning Teaching Material for Improving Mathematical Understanding Ability and Spatial Sense of Junior High School Students

    NASA Astrophysics Data System (ADS)

    Nurjanah; Dahlan, J. A.; Wibisono, Y.

    2017-02-01

    This paper aims to make a design and development computer-based e-learning teaching material for improving mathematical understanding ability and spatial sense of junior high school students. Furthermore, the particular aims are (1) getting teaching material design, evaluation model, and intrument to measure mathematical understanding ability and spatial sense of junior high school students; (2) conducting trials computer-based e-learning teaching material model, asessment, and instrument to develop mathematical understanding ability and spatial sense of junior high school students; (3) completing teaching material models of computer-based e-learning, assessment, and develop mathematical understanding ability and spatial sense of junior high school students; (4) resulting research product is teaching materials of computer-based e-learning. Furthermore, the product is an interactive learning disc. The research method is used of this study is developmental research which is conducted by thought experiment and instruction experiment. The result showed that teaching materials could be used very well. This is based on the validation of computer-based e-learning teaching materials, which is validated by 5 multimedia experts. The judgement result of face and content validity of 5 validator shows that the same judgement result to the face and content validity of each item test of mathematical understanding ability and spatial sense. The reliability test of mathematical understanding ability and spatial sense are 0,929 and 0,939. This reliability test is very high. While the validity of both tests have a high and very high criteria.

  12. The Effects of Unitization on Familiarity-Based Source Memory: Testing a Behavioral Prediction Derived From Neuroimaging Data

    ERIC Educational Resources Information Center

    Diana, Rachel A.; Yonelinas, Andrew P.; Ranganath, Charan

    2008-01-01

    Performance on tests of source memory is typically based on recollection of contextual information associated with an item. However, recent neuroimaging results have suggested that the perirhinal cortex, a region thought to support familiarity-based item recognition, may support source attributions if source information is encoded as a feature of…

  13. Development of safe, green and high performance ionic liquids-based batteries (ILLIBATT project)

    NASA Astrophysics Data System (ADS)

    Balducci, A.; Jeong, S. S.; Kim, G. T.; Passerini, S.; Winter, M.; Schmuck, M.; Appetecchi, G. B.; Marcilla, R.; Mecerreyes, D.; Barsukov, V.; Khomenko, V.; Cantero, I.; De Meatza, I.; Holzapfel, M.; Tran, N.

    This manuscript presents the work carried out within the European project ILLIBATT, which was dedicated to the development of green, safe and high performance ionic liquids-based lithium batteries. Different types of ionic liquids-based electrolytes were developed in the project, based on different ionic liquids and polymers. Using these electrolytes, the performance of several anodic and cathodic materials has been tested and promising results have been obtained. Also, electrodes were formulated using water soluble binders. Using these innovative components, lithium-ion and lithium-metal battery prototypes (0.7-0.8 Ah) have been assembled and cycled between 100% and 0% SOC. The results of these tests showed that such ionic liquids-based prototypes are able to display high capacity, high coulombic efficiency and high cycle life. Moreover, safety tests showed that the introduction of these alternative electrolytes positively contribute to the safety of the batteries.

  14. Electric vehicle chassis dynamometer test methods at JPL and their correlation to track tests

    NASA Technical Reports Server (NTRS)

    Marte, J.; Bryant, J.

    1983-01-01

    Early in its electric vehicle (EV) test program, JPL recognized that EV test procedures were too vague and too loosely defined to permit much meaningful data to be obtained from the testing. Therefore, JPL adopted more stringent test procedures and chose the chassis dynamometer rather than the track as its principal test technique. Through the years, test procedures continued to evolve towards a methodology based on chassis dynamometers which would exhibit good correlation with track testing. Based on comparative dynamometer and track test results on the ETV-1 vehicle, the test methods discussed in this report demonstrate a means by which excellent track-to-dynamometer correlation can be obtained.

  15. NAEP: Gold Standard or Fool's Gold?

    ERIC Educational Resources Information Center

    Popham, W. James

    2005-01-01

    Results of tests of students' skills and knowledge conducted by the National Assessment of Educational Progress (NAEP) and the state accountability tests required by the No Child Left Behind (NCLB) program should not be compared. The two tests are based on different standards and have different measurement functions and judging the results of one…

  16. Design and preliminary test results at Mach 5 of an axisymmetric slotted sound shield. [for supersonic wind tunnels (noise reduction in wind tunnel nozzles)

    NASA Technical Reports Server (NTRS)

    Beckwith, I. E.; Spokowski, A. J.; Harvey, W. D.; Stainback, P. C.

    1975-01-01

    The basic theory and sound attenuation mechanisms, the design procedures, and preliminary experimental results are presented for a small axisymmetric sound shield for supersonic wind tunnels. The shield consists of an array of small diameter rods aligned nearly parallel to the entrance flow with small gaps between the rods for boundary layer suction. Results show that at the lowest test Reynolds number (based on rod diameter) of 52,000 the noise shield reduced the test section noise by about 60 percent ( or 8 db attenuation) but no attenuation was measured for the higher range of test reynolds numbers from 73,000 to 190,000. These results are below expectations based on data reported elsewhere on a flat sound shield model. The smaller attenuation from the present tests is attributed to insufficient suction at the gaps to prevent feedback of vacuum manifold noise into the shielded test flow and to insufficient suction to prevent transition of the rod boundary layers to turbulent flow at the higher Reynolds numbers. Schlieren photographs of the flow are shown.

  17. Gear Fault Diagnosis Based on BP Neural Network

    NASA Astrophysics Data System (ADS)

    Huang, Yongsheng; Huang, Ruoshi

    2018-03-01

    Gear transmission is more complex, widely used in machinery fields, which form of fault has some nonlinear characteristics. This paper uses BP neural network to train the gear of four typical failure modes, and achieves satisfactory results. Tested by using test data, test results have an agreement with the actual results. The results show that the BP neural network can effectively solve the complex state of gear fault in the gear fault diagnosis.

  18. Breaking tester for examining strength of consolidated starch

    NASA Astrophysics Data System (ADS)

    Stasiak, Mateusz; Molenda, Marek; Bańda, Maciej; Wiącek, Joanna; Dobrzański, Bohdan; Parafiniuk, Piotr

    2017-04-01

    A new method based on the measurement of force required to break by bending a vertical column of consolidated powder was elaborated, and its results were compared with the ones obtained from the Jenike shear test. A new apparatus was built based on a vertical cylindrical chamber divided into two cylinders connected with a horizontal hinge. The apparatus was tested with samples of potato, maize and wheat starches with moisture content of 6, 12 and 17% and with the addition of a lubricant. Results of testing revealed significant differences in measured force required to rotate the upper part of the cylinder away from the lower one. The average force varied from 0.138 N for maize starch to 0.143 N for potato starch, while, for various moisture contents, the measured force varied from 0.135 N for 6% to 0.143 N for 17% mc. The results were compared with the results of a direct shear test.

  19. Development of a model to simulate infection dynamics of Mycobacterium bovis in cattle herds in the United States

    PubMed Central

    Smith, Rebecca L.; Schukken, Ynte H.; Lu, Zhao; Mitchell, Rebecca M.; Grohn, Yrjo T.

    2013-01-01

    Objective To develop a mathematical model to simulate infection dynamics of Mycobacterium bovis in cattle herds in the United States and predict efficacy of the current national control strategy for tuberculosis in cattle. Design Stochastic simulation model. Sample Theoretical cattle herds in the United States. Procedures A model of within-herd M bovis transmission dynamics following introduction of 1 latently infected cow was developed. Frequency- and density-dependent transmission modes and 3 tuberculin-test based culling strategies (no test-based culling, constant (annual) testing with test-based culling, and the current strategy of slaughterhouse detection-based testing and culling) were investigated. Results were evaluated for 3 herd sizes over a 10-year period and validated via simulation of known outbreaks of M bovis infection. Results On the basis of 1,000 simulations (1000 herds each) at replacement rates typical for dairy cattle (0.33/y), median time to detection of M bovis infection in medium-sized herds (276 adult cattle) via slaughterhouse surveillance was 27 months after introduction, and 58% of these herds would spontaneously clear the infection prior to that time. Sixty-two percent of medium-sized herds without intervention and 99% of those managed with constant test-based culling were predicted to clear infection < 10 years after introduction. The model predicted observed outbreaks best for frequency-dependent transmission, and probability of clearance was most sensitive to replacement rate. Conclusions and Clinical Relevance Although modeling indicated the current national control strategy was sufficient for elimination of M bovis infection from dairy herds after detection, slaughterhouse surveillance was not sufficient to detect M bovis infection in all herds and resulted in subjectively delayed detection, compared with the constant testing method. Further research is required to economically optimize this strategy. PMID:23865885

  20. Predicting Student Performance in Statewide High-Stakes Tests for Middle School Mathematics Using the Results from Third Party Testing Instruments

    ERIC Educational Resources Information Center

    Meylani, Rusen; Bitter, Gary G.; Castaneda, Rene

    2014-01-01

    In this study regression and neural networks based methods are used to predict statewide high-stakes test results for middle school mathematics using the scores obtained from third party tests throughout the school year. Such prediction is of utmost significance for school districts to live up to the state's educational standards mandated by the…

  1. On-orbit characterization of hyperspectral imagers

    NASA Astrophysics Data System (ADS)

    McCorkel, Joel

    Remote Sensing Group (RSG) at the University of Arizona has a long history of using ground-based test sites for the calibration of airborne- and satellite-based sensors. Often, ground-truth measurements at these tests sites are not always successful due to weather and funding availability. Therefore, RSG has also employed automated ground instrument approaches and cross-calibration methods to verify the radiometric calibration of a sensor. The goal in the cross-calibration method is to transfer the calibration of a well-known sensor to that of a different sensor. This dissertation presents a method for determining the radiometric calibration of a hyperspectral imager using multispectral imagery. The work relies on a multispectral sensor, Moderate-resolution Imaging Spectroradiometer (MODIS), as a reference for the hyperspectral sensor Hyperion. Test sites used for comparisons are Railroad Valley in Nevada and a portion of the Libyan Desert in North Africa. A method to predict hyperspectral surface reflectance using a combination of MODIS data and spectral shape information is developed and applied for the characterization of Hyperion. Spectral shape information is based on RSG's historical in situ data for the Railroad Valley test site and spectral library data for the Libyan test site. Average atmospheric parameters, also based on historical measurements, are used in reflectance prediction and transfer to space. Results of several cross-calibration scenarios that differ in image acquisition coincidence, test site, and reference sensor are found for the characterization of Hyperion. These are compared with results from the reflectance-based approach of vicarious calibration, a well-documented method developed by the RSG that serves as a baseline for calibration performance for the cross-calibration method developed here. Cross-calibration provides results that are within 2% of those of reflectance-based results in most spectral regions. Larger disagreements exist for shorter wavelengths studied in this work as well as in spectral areas that experience absorption by the atmosphere.

  2. What do results from coordinate-based meta-analyses tell us?

    PubMed

    Albajes-Eizagirre, Anton; Radua, Joaquim

    2018-08-01

    Coordinate-based meta-analyses (CBMA) methods, such as Activation Likelihood Estimation (ALE) and Seed-based d Mapping (SDM), have become an invaluable tool for summarizing the findings of voxel-based neuroimaging studies. However, the progressive sophistication of these methods may have concealed two particularities of their statistical tests. Common univariate voxelwise tests (such as the t/z-tests used in SPM and FSL) detect voxels that activate, or voxels that show differences between groups. Conversely, the tests conducted in CBMA test for "spatial convergence" of findings, i.e., they detect regions where studies report "more peaks than in most regions", regions that activate "more than most regions do", or regions that show "larger differences between groups than most regions do". The first particularity is that these tests rely on two spatial assumptions (voxels are independent and have the same probability to have a "false" peak), whose violation may make their results either conservative or liberal, though fortunately current versions of ALE, SDM and some other methods consider these assumptions. The second particularity is that the use of these tests involves an important paradox: the statistical power to detect a given effect is higher if there are no other effects in the brain, whereas lower in presence of multiple effects. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Development and validation of a smartphone-based digits-in-noise hearing test in South African English.

    PubMed

    Potgieter, Jenni-Marí; Swanepoel, De Wet; Myburgh, Hermanus Carel; Hopper, Thomas Christopher; Smits, Cas

    2015-07-01

    The objective of this study was to develop and validate a smartphone-based digits-in-noise hearing test for South African English. Single digits (0-9) were recorded and spoken by a first language English female speaker. Level corrections were applied to create a set of homogeneous digits with steep speech recognition functions. A smartphone application was created to utilize 120 digit-triplets in noise as test material. An adaptive test procedure determined the speech reception threshold (SRT). Experiments were performed to determine headphones effects on the SRT and to establish normative data. Participants consisted of 40 normal-hearing subjects with thresholds ≤15 dB across the frequency spectrum (250-8000 Hz) and 186 subjects with normal-hearing in both ears, or normal-hearing in the better ear. The results show steep speech recognition functions with a slope of 20%/dB for digit-triplets presented in noise using the smartphone application. The results of five headphone types indicate that the smartphone-based hearing test is reliable and can be conducted using standard Android smartphone headphones or clinical headphones. A digits-in-noise hearing test was developed and validated for South Africa. The mean SRT and speech recognition functions correspond to previous developed telephone-based digits-in-noise tests.

  4. Droplet digital PCR-based EGFR mutation detection with an internal quality control index to determine the quality of DNA.

    PubMed

    Kim, Sung-Su; Choi, Hyun-Jeung; Kim, Jin Ju; Kim, M Sun; Lee, In-Seon; Byun, Bohyun; Jia, Lina; Oh, Myung Ryurl; Moon, Youngho; Park, Sarah; Choi, Joon-Seok; Chae, Seoung Wan; Nam, Byung-Ho; Kim, Jin-Soo; Kim, Jihun; Min, Byung Soh; Lee, Jae Seok; Won, Jae-Kyung; Cho, Soo Youn; Choi, Yoon-La; Shin, Young Kee

    2018-01-11

    In clinical translational research and molecular in vitro diagnostics, a major challenge in the detection of genetic mutations is overcoming artefactual results caused by the low-quality of formalin-fixed paraffin-embedded tissue (FFPET)-derived DNA (FFPET-DNA). Here, we propose the use of an 'internal quality control (iQC) index' as a criterion for judging the minimum quality of DNA for PCR-based analyses. In a pre-clinical study comparing the results from droplet digital PCR-based EGFR mutation test (ddEGFR test) and qPCR-based EGFR mutation test (cobas EGFR test), iQC index ≥ 0.5 (iQC copies ≥ 500, using 3.3 ng of FFPET-DNA [1,000 genome equivalents]) was established, indicating that more than half of the input DNA was amplifiable. Using this criterion, we conducted a retrospective comparative clinical study of the ddEGFR and cobas EGFR tests for the detection of EGFR mutations in non-small cell lung cancer (NSCLC) FFPET-DNA samples. Compared with the cobas EGFR test, the ddEGFR test exhibited superior analytical performance and equivalent or higher clinical performance. Furthermore, iQC index is a reliable indicator of the quality of FFPET-DNA and could be used to prevent incorrect diagnoses arising from low-quality samples.

  5. Incorporating personalized gene sequence variants, molecular genetics knowledge, and health knowledge into an EHR prototype based on the Continuity of Care Record standard.

    PubMed

    Jing, Xia; Kay, Stephen; Marley, Thomas; Hardiker, Nicholas R; Cimino, James J

    2012-02-01

    The current volume and complexity of genetic tests, and the molecular genetics knowledge and health knowledge related to interpretation of the results of those tests, are rapidly outstripping the ability of individual clinicians to recall, understand and convey to their patients information relevant to their care. The tailoring of molecular genetics knowledge and health knowledge in clinical settings is important both for the provision of personalized medicine and to reduce clinician information overload. In this paper we describe the incorporation, customization and demonstration of molecular genetic data (mainly sequence variants), molecular genetics knowledge and health knowledge into a standards-based electronic health record (EHR) prototype developed specifically for this study. We extended the CCR (Continuity of Care Record), an existing EHR standard for representing clinical data, to include molecular genetic data. An EHR prototype was built based on the extended CCR and designed to display relevant molecular genetics knowledge and health knowledge from an existing knowledge base for cystic fibrosis (OntoKBCF). We reconstructed test records from published case reports and represented them in the CCR schema. We then used the EHR to dynamically filter molecular genetics knowledge and health knowledge from OntoKBCF using molecular genetic data and clinical data from the test cases. The molecular genetic data were successfully incorporated in the CCR by creating a category of laboratory results called "Molecular Genetics" and specifying a particular class of test ("Gene Mutation Test") in this category. Unlike other laboratory tests reported in the CCR, results of tests in this class required additional attributes ("Molecular Structure" and "Molecular Position") to support interpretation by clinicians. These results, along with clinical data (age, sex, ethnicity, diagnostic procedures, and therapies) were used by the EHR to filter and present molecular genetics knowledge and health knowledge from OntoKBCF. This research shows a feasible model for delivering patient sequence variants and presenting tailored molecular genetics knowledge and health knowledge via a standards-based EHR system prototype. EHR standards can be extended to include the necessary patient data (as we have demonstrated in the case of the CCR), while knowledge can be obtained from external knowledge bases that are created and maintained independently from the EHR. This approach can form the basis for a personalized medicine framework, a more comprehensive standards-based EHR system and a potential platform for advancing translational research by both disseminating results and providing opportunities for new insights into phenotype-genotype relationships. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. A Cost-Effectiveness Analysis of a Home-Based HIV Counselling and Testing Intervention versus the Standard (Facility Based) HIV Testing Strategy in Rural South Africa

    PubMed Central

    Tabana, Hanani; Nkonki, Lungiswa; Hongoro, Charles; Doherty, Tanya; Ekström, Anna Mia; Naik, Reshma; Zembe-Mkabile, Wanga; Jackson, Debra; Thorson, Anna

    2015-01-01

    Introduction There is growing evidence concerning the acceptability and feasibility of home-based HIV testing. However, less is known about the cost-effectiveness of the approach yet it is a critical component to guide decisions about scaling up access to HIV testing. This study examined the cost-effectiveness of a home-based HIV testing intervention in rural South Africa. Methods Two alternatives: clinic and home-based HIV counselling and testing were compared. Costs were analysed from a provider’s perspective for the period of January to December 2010. The outcome, HIV counselling and testing (HCT) uptake was obtained from the Good Start home-based HIV counselling and testing (HBHCT) cluster randomised control trial undertaken in KwaZulu-Natal province. Cost-effectiveness was estimated for a target population of 22,099 versus 23,864 people for intervention and control communities respectively. Average costs were calculated as the cost per client tested, while cost-effectiveness was calculated as the cost per additional client tested through HBHCT. Results Based on effectiveness of 37% in the intervention (HBHCT) arm compared to 16% in control arm, home based testing costs US$29 compared to US$38 per person for clinic HCT. The incremental cost effectiveness per client tested using HBHCT was $19. Conclusions HBHCT was less costly and more effective. Home-based HCT could present a cost-effective alternative for rural ‘hard to reach’ populations depending on affordability by the health system, and should be considered as part of community outreach programs. PMID:26275059

  7. Mobile HIV screening in Cape Town, South Africa: clinical impact, cost and cost-effectiveness.

    PubMed

    Bassett, Ingrid V; Govindasamy, Darshini; Erlwanger, Alison S; Hyle, Emily P; Kranzer, Katharina; van Schaik, Nienke; Noubary, Farzad; Paltiel, A David; Wood, Robin; Walensky, Rochelle P; Losina, Elena; Bekker, Linda-Gail; Freedberg, Kenneth A

    2014-01-01

    Mobile HIV screening may facilitate early HIV diagnosis. Our objective was to examine the cost-effectiveness of adding a mobile screening unit to current medical facility-based HIV testing in Cape Town, South Africa. We used the Cost Effectiveness of Preventing AIDS Complications International (CEPAC-I) computer simulation model to evaluate two HIV screening strategies in Cape Town: 1) medical facility-based testing (the current standard of care) and 2) addition of a mobile HIV-testing unit intervention in the same community. Baseline input parameters were derived from a Cape Town-based mobile unit that tested 18,870 individuals over 2 years: prevalence of previously undiagnosed HIV (6.6%), mean CD4 count at diagnosis (males 423/µL, females 516/µL), CD4 count-dependent linkage to care rates (males 31%-58%, females 49%-58%), mobile unit intervention cost (includes acquisition, operation and HIV test costs, $29.30 per negative result and $31.30 per positive result). We conducted extensive sensitivity analyses to evaluate input uncertainty. Model outcomes included site of HIV diagnosis, life expectancy, medical costs, and the incremental cost-effectiveness ratio (ICER) of the intervention compared to medical facility-based testing. We considered the intervention to be "very cost-effective" when the ICER was less than South Africa's annual per capita Gross Domestic Product (GDP) ($8,200 in 2012). We projected that, with medical facility-based testing, the discounted (undiscounted) HIV-infected population life expectancy was 132.2 (197.7) months; this increased to 140.7 (211.7) months with the addition of the mobile unit. The ICER for the mobile unit was $2,400/year of life saved (YLS). Results were most sensitive to the previously undiagnosed HIV prevalence, linkage to care rates, and frequency of HIV testing at medical facilities. The addition of mobile HIV screening to current testing programs can improve survival and be very cost-effective in South Africa and other resource-limited settings, and should be a priority.

  8. Internet-Based HIV and Sexually Transmitted Infection Testing in British Columbia, Canada: Opinions and Expectations of Prospective Clients

    PubMed Central

    Hottes, Travis Salway; Farrell, Janine; Bondyra, Mark; Haag, Devon; Shoveller, Jean

    2012-01-01

    Background The feasibility and acceptability of Internet-based sexually transmitted infection (STI) testing have been demonstrated; however, few programs have included testing for human immunodeficiency virus (HIV). In British Columbia, Canada, a new initiative will offer online access to chlamydia, gonorrhea, syphilis, and HIV testing, integrated with existing clinic-based services. We presented the model to gay men and other men who have sex with men (MSM) and existing clinic clients through a series of focus groups. Objective To identify perceived benefits, concerns, and expectations of a new model for Internet-based STI and HIV testing among potential end users. Methods Participants were recruited through email invitations, online classifieds, and flyers in STI clinics. A structured interview guide was used. Focus groups were audio recorded, and an observer took detailed field notes. Analysts then listened to audio recordings to validate field notes. Data were coded and analyzed using a scissor-and-sort technique. Results In total, 39 people participated in six focus groups. Most were MSM, and all were active Internet users and experienced with STI/HIV testing. Perceived benefits of Internet-based STI testing included anonymity, convenience, and client-centered control. Salient concerns were reluctance to provide personal information online, distrust of security of data provided online, and the need for comprehensive pretest information and support for those receiving positive results, particularly for HIV. Suggestions emerged for mitigation of these concerns: provide up-front and detailed information about the model, ask only the minimal information required for testing, give positive results only by phone or in person, and ensure that those testing positive are referred for counseling and support. End users expected Internet testing to offer continuous online service delivery, from booking appointments, to transmitting information to the laboratory, to getting prescriptions. Most participants said they would use the service or recommend it to others. Those who indicated they would be unlikely to use it generally either lived near an STI clinic or routinely saw a family doctor with whom they were comfortable testing. Participants expected that the service would provide the greatest benefit to individuals who do not already have access to sensitive sexual health services, are reluctant to test due to stigma, or want to take immediate action (eg, because of a recent potential STI/HIV exposure). Conclusions Internet-based STI/HIV testing has the potential to reduce barriers to testing, as a complement to existing clinic-based services. Trust in the new online service, however, is a prerequisite to client uptake and may be engendered by transparency of information about the model, and by accounting for concerns related to confidentiality, data usage, and provision of positive (especially HIV) results. Ongoing evaluation of this new model will be essential to its success and to the confidence of its users. PMID:22394997

  9. Development of a database and processing method for detecting hematotoxicity adverse drug events.

    PubMed

    Shimai, Yoshie; Takeda, Toshihiro; Manabe, Shirou; Teramoto, Kei; Mihara, Naoki; Matsumura, Yasushi

    2015-01-01

    Adverse events are detected by monitoring the patient's status, including blood test results. However, it is difficult to identify all adverse events based on recognition by individual doctors. We developed a system that can be used to detect hematotoxicity adverse events according to blood test results recorded in an electronic medical record system. The blood test results were graded based on Common Terminology Criteria for Adverse Events (CTCAE) and changes in the blood test results (Up, Down, Flat) were assessed according to the variation in the grade. The changes in the blood test and injection data were stored in a database. By comparing the date of injection and start and end dates of the change in the blood test results, adverse events related to a designated drug were detected. Using this method, we searched for the occurrence of serious adverse events (CTCAE Grades 3 or 4) concerning WBC, ALT and creatinine related to paclitaxel at Osaka University Hospital. The rate of occurrence of a decreased WBC count, increased ALT level and increased creatinine level was 36.0%, 0.6% and 0.4%, respectively. This method is useful for detecting and estimating the rate of occurrence of hematotoxicity adverse drug events.

  10. The 0.040-scale space shuttle orbiter base heating model tests in the Lewis Research Center space power facility

    NASA Technical Reports Server (NTRS)

    Dezelick, R. A.

    1976-01-01

    Space shuttle base heating tests were conducted using a 0.040-scale model in the Plum Brook Space Power Facility of The NASA Lewis Research Center. The tests measured heat transfer rates, pressure distributions, and gas recovery temperatures on the orbiter vehicle 2A base configuration resulting from engine plume impingement. One hundred and sixty-eight hydrogen-oxygen engine firings were made at simulated flight altitudes ranging from 120,000 to 360,000 feet.

  11. Combine Flash-Based FPGA TID and Long-Term Retention Reliabilities Through VT Shift

    NASA Astrophysics Data System (ADS)

    Wang, Jih-Jong; Rezzak, Nadia; Dsilva, Durwyn; Xue, Fengliang; Samiee, Salim; Singaraju, Pavan; Jia, James; Nguyen, Victor; Hawley, Frank; Hamdy, Esmat

    2016-08-01

    Reliability test results of data retention and total ionizing dose (TID) in 65 nm Flash-based field programmable gate array (FPGA) are presented. Long-chain inverter design is recommended for reliability evaluation because it is the worst case design for both effects. Based on preliminary test data, both issues are unified and modeled by one natural decay equation. The relative contributions of TID induced threshold-voltage shift and retention mechanisms are evaluated by analyzing test data.

  12. Physician pattern of patient notification of test results.

    PubMed

    Thiedke, Carolyn C; Hoeft, Katherine A; Pearson, William S

    2005-01-01

    To discover how community-based family physicians notify patients of test results and whether there are differences based on sex, length of time in practice, reimbursement status, employment status,or percentage of practice in managed care. We mailed a survey to 500 randomly selected members of the South Carolina chapter of the American Academy of Family Physicians. All analyses were preformed using SASTM version 8.2. Both descriptive and inferential statistics were used to analyze the collected data. A total of 367 physicians responded (73% response rate). The main outcome variable was the time each physician spent notifying patients of test results: a mean of 20.86 +/- 18.3 minutes per day(range 0-120 minutes/day). Women physicians and those with more than 75% managed care were significantly more likely to spend more than the median time notifying patients of test results. Physicians vary in the amount of time they spend notifying patients of their test results, with female physicians and those with more than 75% of their practice in managed care spending more time than do male physicians and physicians with less managed care.

  13. Sequence variant classification and reporting: recommendations for improving the interpretation of cancer susceptibility genetic test results

    PubMed Central

    Plon, Sharon E.; Eccles, Diana M.; Easton, Douglas; Foulkes, William D.; Genuardi, Maurizio; Greenblatt, Marc S.; Hogervorst, Frans B.L.; Hoogerbrugge, Nicoline; Spurdle, Amanda B.; Tavtigian, Sean

    2011-01-01

    Genetic testing of cancer susceptibility genes is now widely applied in clinical practice to predict risk of developing cancer. In general, sequence-based testing of germline DNA is used to determine whether an individual carries a change that is clearly likely to disrupt normal gene function. Genetic testing may detect changes that are clearly pathogenic, clearly neutral or variants of unclear clinical significance. Such variants present a considerable challenge to the diagnostic laboratory and the receiving clinician in terms of interpretation and clear presentation of the implications of the result to the patient. There does not appear to be a consistent approach to interpreting and reporting the clinical significance of variants either among genes or among laboratories. The potential for confusion among clinicians and patients is considerable and misinterpretation may lead to inappropriate clinical consequences. In this article we review the current state of sequence-based genetic testing, describe other standardized reporting systems used in oncology and propose a standardized classification system for application to sequence based results for cancer predisposition genes. We suggest a system of five classes of variants based on the degree of likelihood of pathogenicity. Each class is associated with specific recommendations for clinical management of at-risk relatives that will depend on the syndrome. We propose that panels of experts on each cancer predisposition syndrome facilitate the classification scheme and designate appropriate surveillance and cancer management guidelines. The international adoption of a standardized reporting system should improve the clinical utility of sequence-based genetic tests to predict cancer risk. PMID:18951446

  14. The Clinical Delivery of Pharmacogenetic Testing Services: A Proposed Partnership between Genetic Counselors and Pharmacists

    PubMed Central

    Mills, Rachel; Haga, Susanne B.

    2013-01-01

    One of the basic questions in the early uses of pharmacogenetic (PGx) testing revolves around the clinical delivery of testing. Because multiple health professionals may play a role in the delivery of PGx testing, various clinical delivery models have begun to be studied. We propose that a partnership between genetic counselors and pharmacists can assist clinicians in the delivery of comprehensive PGx services. Based on their expert knowledge of pharmacokinetics and pharmacodynamics, pharmacists can facilitate the appropriate application of PGx test results to adjust medication use as warranted and act as a liaison to the healthcare team recommending changes in medication based on test results and patient input. Genetic counselors are well-trained in genetics as well as risk communication and counseling methodology, but have limited knowledge of pharmaceuticals. The complementary knowledge and skill set supports the partnership between genetic counselors and pharmacists to provide effective PGx testing services. PMID:23746189

  15. NASA Contractor Report: Guidelines for Proof Test Analysis

    NASA Technical Reports Server (NTRS)

    Chell, G. G.; McClung, R. C.; Kuhlman, C. J.; Russell, D. A.; Garr, K.; Donnelly, B.

    1997-01-01

    These Guidelines integrate state-of-the-art Elastic-Plastic Fracture Mechanics (EPFM) and proof test implementation issues into a comprehensive proof test analysis procedure in the form of a Road Map which identifies the types of data, fracture mechanics based parameters, and calculations needed to perform flaw screening and minimum proof load analyses of fracture critical components. Worked examples are presented to illustrate the application of the Road Map to proof test analysis. The state-of-the-art fracture technology employed in these Guidelines is based on the EPFM parameter, J, and a pictorial representation of a J fracture analysis, called the Failure Assessment Diagram (FAD) approach. The recommended fracture technology is validated using finite element J results, and laboratory and hardware fracture test results on the nickel-based superalloy IN-718, the aluminum alloy 2024-T351 1, and ferritic pressure vessel steels. In all cases the laboratory specimens and hardware failed by ductile mechanisms. Advanced proof test analyses involving probability analysis and Multiple Cycle Proof Testing (MCPT) are addressed. Finally, recommendations are provided on to how to account for the effects of the proof test overload on subsequent service fatigue and fracture behaviors.

  16. Is maternal plasma DNA testing impacting serum-based screening for aneuploidy in the United States?

    PubMed

    Palomaki, Glenn E; Ashwood, Edward R; Best, Robert G; Lambert-Messerlian, Geralyn; Knight, George J

    2015-11-01

    We sought to determine whether tests for fetal aneuploidy based on next-generation sequencing of cell-free DNA in maternal circulation have had an impact on routine serum-based screening in the general pregnant population. We compared results from laboratory surveys in 2011 and 2014 that reported types of prenatal serum screening tests and numbers of tests performed. Testing records from two prenatal serum screening laboratories examined temporal trends in the proportion of screened women 35 years of age and older from 2008 (or 2009) to 2014. The 82 laboratory survey results available for comparison showed that 1.7 million women were screened in 2014, a 5% increase over 2011. In the two screening laboratories, the proportion of screened women age 35 and older increased for several years but then experienced reductions of 8 and 18% by mid-2014 when compared with the highest rates observed. As of 2014, maternal plasma DNA testing appears to have had only a minor impact on serum screening rates in the United States. Ongoing surveillance has the potential to determine if, and when, DNA testing begins to replace serum testing as a primary screen for Down syndrome in the United States.

  17. Use of Commercial FPGA-Based Evaluation Boards for Single-Event Testing of DDR2 and DDR3 SDRAMs

    NASA Technical Reports Server (NTRS)

    Ladbury, R. L.; Berg, M. D.; Wilcox, E. P.; LaBel, K. A.; Kim, H. S.; Phan, A. M.; Seidleck, C. M.

    2013-01-01

    We investigate the use of commercial FPGA based evaluation boards for radiation testing DDR2 and DDR3 SDRAMs. We evaluate the resulting data quality and the tradeoffs involved in the use of these boards.

  18. How Reliable Is Laboratory Testing?

    MedlinePlus

    ... laboratory testing. (See Who's Who in the Lab .) Post-Analytic Activities After the test is completed, the result must be delivered in ... View Sources NOTE: This article is based on research that ... of the Lab Tests Online Editorial Review Board . This article is periodically ...

  19. Nucleic acid-based diagnostics for infectious diseases in public health affairs.

    PubMed

    Yu, Albert Cheung-Hoi; Vatcher, Greg; Yue, Xin; Dong, Yan; Li, Mao Hua; Tam, Patrick H K; Tsang, Parker Y L; Wong, April K Y; Hui, Michael H K; Yang, Bin; Tang, Hao; Lau, Lok-Ting

    2012-06-01

    Infectious diseases, mostly caused by bacteria and viruses but also a result of fungal and parasitic infection, have been one of the most important public health concerns throughout human history. The first step in combating these pathogens is to get a timely and accurate diagnosis at an affordable cost. Many kinds of diagnostics have been developed, such as pathogen culture, biochemical tests and serological tests, to help detect and fight against the causative agents of diseases. However, these diagnostic tests are generally unsatisfactory because they are not particularly sensitive and specific and are unable to deliver speedy results. Nucleic acid-based diagnostics, detecting pathogens through the identification of their genomic sequences, have shown promise to overcome the above limitations and become more widely adopted in clinical tests. Here we review some of the most popular nucleic acid-based diagnostics and focus on their adaptability and applicability to routine clinical usage. We also compare and contrast the characteristics of different types of nucleic acid-based diagnostics.

  20. Laboratory medicine handoff gaps experienced by primary care practices: A report from the shared networks of collaborative ambulatory practices and partners (SNOCAP).

    PubMed

    West, David R; James, Katherine A; Fernald, Douglas H; Zelie, Claire; Smith, Maxwell L; Raab, Stephen S

    2014-01-01

    The majority of errors in laboratory medicine testing are thought to occur in the pre- and postanalytic testing phases, and a large proportion of these errors are secondary to failed handoffs. Because most laboratory tests originate in ambulatory primary care, understanding the gaps in handoff processes within and between laboratories and practices is imperative for patient safety. Therefore, the purpose of this study was to understand, based on information from primary care practice personnel, the perceived gaps in laboratory processes as a precursor to initiating process improvement activities. A survey was used to assess perceptions of clinicians, staff, and management personnel of gaps in handoffs between primary care practices and laboratories working in 21 Colorado primary care practices. Data were analyzed to determine statistically significant associations between categorical variables. In addition, qualitative analysis of responses to open-ended survey questions was conducted. Primary care practices consistently reported challenges and a desire/need to improve their efforts to systematically track laboratory test status, confirm receipt of laboratory results, and report results to patients. Automated tracking systems existed in roughly 61% of practices, and all but one of those had electronic health record-based tracking systems in place. One fourth of these electronic health record-enabled practices expressed sufficient mistrust in these systems to warrant the concurrent operation of an article-based tracking system as backup. Practices also reported 12 different procedures used to notify patients of test results, varying by test result type. The results highlight the lack of standardization and definition of roles in handoffs in primary care laboratory practices for test ordering, monitoring, and receiving and reporting test results. Results also identify high-priority gaps in processes and the perceptions by practice personnel that practice improvement in these areas is needed. Commonalities in these areas warrant the development and support of tools for use in primary care settings. © Copyright 2014 by the American Board of Family Medicine.

  1. Design of durability test protocol for vehicular fuel cell systems operated in power-follow mode based on statistical results of on-road data

    NASA Astrophysics Data System (ADS)

    Xu, Liangfei; Reimer, Uwe; Li, Jianqiu; Huang, Haiyan; Hu, Zunyan; Jiang, Hongliang; Janßen, Holger; Ouyang, Minggao; Lehnert, Werner

    2018-02-01

    City buses using polymer electrolyte membrane (PEM) fuel cells are considered to be the most likely fuel cell vehicles to be commercialized in China. The technical specifications of the fuel cell systems (FCSs) these buses are equipped with will differ based on the powertrain configurations and vehicle control strategies, but can generally be classified into the power-follow and soft-run modes. Each mode imposes different levels of electrochemical stress on the fuel cells. Evaluating the aging behavior of fuel cell stacks under the conditions encountered in fuel cell buses requires new durability test protocols based on statistical results obtained during actual driving tests. In this study, we propose a systematic design method for fuel cell durability test protocols that correspond to the power-follow mode based on three parameters for different fuel cell load ranges. The powertrain configurations and control strategy are described herein, followed by a presentation of the statistical data for the duty cycles of FCSs in one city bus in the demonstration project. Assessment protocols are presented based on the statistical results using mathematical optimization methods, and are compared to existing protocols with respect to common factors, such as time at open circuit voltage and root-mean-square power.

  2. Increasing HIV testing engagement through provision of home HIV self-testing kits for patients who decline testing in the emergency department: a pilot randomisation study.

    PubMed

    Patel, Anuj V; Abrams, Samuel M; Gaydos, Charlotte A; Jett-Goheen, Mary; Latkin, Carl A; Rothman, Richard E; Hsieh, Yu-Hsiang

    2018-06-14

    Up to 60% of patients decline routine HIV testing offer in US emergency departments (EDs). The objective of this study is to determine whether the provision of HIV self-testing (HIVST) kit would increase engagement of HIV testing among these HIV test 'Decliners'. Patients who declined a test offered in an ED-based triage nurse-driven HIV screening programme were enrolled and randomised to either the HIVST or the control group. The patients in the HIVST group received HIVST kits to take home, were encouraged to report test results to an established internet-based STI/HIV testing recruitment website 'I Want the Kit' (IWTK) and received five referral cards for their peers to request HIVST kits from IWTK. The control group received pamphlets about publicly available HIV testing sites. HIV testing from both groups after enrolment was determined via telephone follow-up at 1 month. Testing rate ratio (RR) was determined using χ 2 tests. Fifty-two patients were randomised to the HIVST group and 48 to the control group. Among all 64 patients completing any follow-up, 14/29 (48%) patients in the HIVST group tested themselves at home with the provided kit. Four of these had never had an HIV test. Only 2/35 (6%) in the control group reported having an HIV test after enrolment (RR: 8.45 (95% CI: 2.09 to 34.17)). 57% (8/14) in the HIVST group reported test results to IWTK. Provision of HIVST kits supplements ED-based screening programme and significantly improved engagement of HIV testing among those test 'Decliners' in the ED. NCT03021005, results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. Stages of Breast Cancer

    MedlinePlus

    ... using a thin needle. If cancer is found, tests are done to study the cancer cells. Decisions about the best treatment are based on the results of these tests. The tests give information about: how quickly the ...

  4. Breast Cancer Treatment

    MedlinePlus

    ... using a thin needle. If cancer is found, tests are done to study the cancer cells. Decisions about the best treatment are based on the results of these tests. The tests give information about: how quickly the ...

  5. Rapid diagnostic tests for malaria at sites of varying transmission intensity in Uganda.

    PubMed

    Hopkins, Heidi; Bebell, Lisa; Kambale, Wilson; Dokomajilar, Christian; Rosenthal, Philip J; Dorsey, Grant

    2008-02-15

    In Africa, fever is often treated presumptively as malaria, resulting in misdiagnosis and the overuse of antimalarial drugs. Rapid diagnostic tests (RDTs) for malaria may allow improved fever management. We compared RDTs based on histidine-rich protein 2 (HRP2) and RDTs based on Plasmodium lactate dehydrogenase (pLDH) with expert microscopy and PCR-corrected microscopy for 7000 patients at sites of varying malaria transmission intensity across Uganda. When all sites were considered, the sensitivity of the HRP2-based test was 97% when compared with microscopy and 98% when corrected by PCR; the sensitivity of the pLDH-based test was 88% when compared with microscopy and 77% when corrected by PCR. The specificity of the HRP2-based test was 71% when compared with microscopy and 88% when corrected by PCR; the specificity of the pLDH-based test was 92% when compared with microscopy and >98% when corrected by PCR. Based on Plasmodium falciparum PCR-corrected microscopy, the positive predictive value (PPV) of the HRP2-based test was high (93%) at all but the site with the lowest transmission rate; the pLDH-based test and expert microscopy offered excellent PPVs (98%) for all sites. The negative predictive value (NPV) of the HRP2-based test was consistently high (>97%); in contrast, the NPV for the pLDH-based test dropped significantly (from 98% to 66%) as transmission intensity increased, and the NPV for expert microscopy decreased significantly (99% to 54%) because of increasing failure to detect subpatent parasitemia. Based on the high PPV and NPV, HRP2-based RDTs are likely to be the best diagnostic choice for areas with medium-to-high malaria transmission rates in Africa.

  6. A Test of Concept Study of At-Home, Self-Administered HIV Testing With Web-Based Peer Counseling Via Video Chat for Men Who Have Sex With Men.

    PubMed

    Maksut, Jessica L; Eaton, Lisa A; Siembida, Elizabeth J; Driffin, Daniel D; Baldwin, Robert

    2016-12-14

    Men who have sex with men (MSM), particularly MSM who identify as African-American or Black (BMSM), are the sociodemographic group that is most heavily burdened by the human immunodeficiency virus (HIV) epidemic in the United States. To meet national HIV testing goals, there must be a greater emphasis on novel ways to promote and deliver HIV testing to MSM. Obstacles to standard, clinic-based HIV testing include concerns about stigmatization or recognition at in-person testing sites, as well as the inability to access a testing site due to logistical barriers. This study examined the feasibility of self-administered, at-home HIV testing with Web-based peer counseling to MSM by using an interactive video chatting method. The aims of this study were to (1) determine whether individuals would participate in at-home HIV testing with video chat-based test counseling with a peer counselor, (2) address logistical barriers to HIV testing that individuals who report risk for HIV transmission may experience, and (3) reduce anticipated HIV stigma, a primary psychosocial barrier to HIV testing. In response to the gap in HIV testing, a pilot study was developed and implemented via mailed, at-home HIV test kits, accompanied by HIV counseling with a peer counselor via video chat. A total of 20 MSM were enrolled in this test of concept study, 80% of whom identified as BMSM. All participants reported that at-home HIV testing with a peer counseling via video chat was a satisfying experience. The majority of participants (13/18, 72%) said they would prefer for their next HIV testing and counseling experience to be at home with Web-based video chat peer counseling, as opposed to testing in an office or clinic setting. Participants were less likely to report logistical and emotional barriers to HIV testing at the 6-week and 3-month follow-ups. The results of this study suggest that self-administered HIV testing with Web-based peer counseling is feasible and that MSM find it to be a satisfactory means by which they can access their test results. This study can serve as a general guideline for future, larger-scale studies of Web-based HIV test counseling for MSM. ©Jessica L Maksut, Lisa A Eaton, Elizabeth J Siembida, Daniel D Driffin, Robert Baldwin. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 14.12.2016.

  7. SMART empirical approaches for predicting field performance of PV modules from results of reliability tests

    NASA Astrophysics Data System (ADS)

    Hardikar, Kedar Y.; Liu, Bill J. J.; Bheemreddy, Venkata

    2016-09-01

    Gaining an understanding of degradation mechanisms and their characterization are critical in developing relevant accelerated tests to ensure PV module performance warranty over a typical lifetime of 25 years. As newer technologies are adapted for PV, including new PV cell technologies, new packaging materials, and newer product designs, the availability of field data over extended periods of time for product performance assessment cannot be expected within the typical timeframe for business decisions. In this work, to enable product design decisions and product performance assessment for PV modules utilizing newer technologies, Simulation and Mechanism based Accelerated Reliability Testing (SMART) methodology and empirical approaches to predict field performance from accelerated test results are presented. The method is demonstrated for field life assessment of flexible PV modules based on degradation mechanisms observed in two accelerated tests, namely, Damp Heat and Thermal Cycling. The method is based on design of accelerated testing scheme with the intent to develop relevant acceleration factor models. The acceleration factor model is validated by extensive reliability testing under different conditions going beyond the established certification standards. Once the acceleration factor model is validated for the test matrix a modeling scheme is developed to predict field performance from results of accelerated testing for particular failure modes of interest. Further refinement of the model can continue as more field data becomes available. While the demonstration of the method in this work is for thin film flexible PV modules, the framework and methodology can be adapted to other PV products.

  8. Road load simulator tests of the Gould phase 1 functional model silicon controlled rectifier ac motor controller for electric vehicles

    NASA Astrophysics Data System (ADS)

    Gourash, F.

    1984-02-01

    The test results for a functional model ac motor controller for electric vehicles and a three-phase induction motor which were dynamically tested on the Lewis Research Center road load simulator are presented. Results show that the controller has the capability to meet the SAE-J227a D cycle test schedule and to accelerate a 1576-kg (3456-lb) simulated vehicle to a cruise speed of 88.5 km/hr (55 mph). Combined motor controller efficiency is 72 percent and the power inverter efficiency alone is 89 percent for the cruise region of the D cycle. Steady state test results for motoring, regeneration, and thermal data obtained by operating the simulator as a conventional dynamometer are in agreement with the contractor's previously reported data. The regeneration test results indicate that a reduction in energy requirements for urban driving cycles is attainable with regenerative braking. Test results and data in this report serve as a data base for further development of ac motor controllers and propulsion systems for electric vehicles. The controller uses state-of-the-art silicon controlled rectifier (SCR) power semiconductors and microprocessor-based logic and control circuitry. The controller was developed by Gould Laboratories under a Lewis contract for the Department of Energy's Electric and Hybrid Vehicle program.

  9. Road load simulator tests of the Gould phase 1 functional model silicon controlled rectifier ac motor controller for electric vehicles

    NASA Technical Reports Server (NTRS)

    Gourash, F.

    1984-01-01

    The test results for a functional model ac motor controller for electric vehicles and a three-phase induction motor which were dynamically tested on the Lewis Research Center road load simulator are presented. Results show that the controller has the capability to meet the SAE-J227a D cycle test schedule and to accelerate a 1576-kg (3456-lb) simulated vehicle to a cruise speed of 88.5 km/hr (55 mph). Combined motor controller efficiency is 72 percent and the power inverter efficiency alone is 89 percent for the cruise region of the D cycle. Steady state test results for motoring, regeneration, and thermal data obtained by operating the simulator as a conventional dynamometer are in agreement with the contractor's previously reported data. The regeneration test results indicate that a reduction in energy requirements for urban driving cycles is attainable with regenerative braking. Test results and data in this report serve as a data base for further development of ac motor controllers and propulsion systems for electric vehicles. The controller uses state-of-the-art silicon controlled rectifier (SCR) power semiconductors and microprocessor-based logic and control circuitry. The controller was developed by Gould Laboratories under a Lewis contract for the Department of Energy's Electric and Hybrid Vehicle program.

  10. Long Duration Life Test of Propylene Glycol Water Based Thermal Fluid Within Thermal Control Loop

    NASA Technical Reports Server (NTRS)

    Le, Hung; Hill, Charles; Stephan, Ryan A.

    2010-01-01

    Evaluations of thermal properties and resistance to microbial growth concluded that 50% Propylene Glycol (PG)-based fluid and 50% de-ionized water mixture was desirable for use as a fluid within a vehicle s thermal control loop. However, previous testing with a commercial mixture of PG and water containing phosphate corrosion inhibitors resulted in corrosion of aluminum within the test system and instability of the test fluid. This paper describes a follow-on long duration testing and analysis of 50% Propylene Glycol (PG)-based fluid and 50% de-ionized water mixture with inorganic corrosion inhibitors used in place of phosphates. The test evaluates the long-term fluid stability and resistance to microbial and chemical changes

  11. The Effectiveness of learning materials based on multiple intelligence on the understanding of global warming

    NASA Astrophysics Data System (ADS)

    Liliawati, W.; Purwanto; Zulfikar, A.; Kamal, R. N.

    2018-05-01

    This study aims to examine the effectiveness of the use of teaching materials based on multiple intelligences on the understanding of high school students’ material on the theme of global warming. The research method used is static-group pretest-posttest design. Participants of the study were 60 high school students of XI class in one of the high schools in Bandung. Participants were divided into two classes of 30 students each for the experimental class and control class. The experimental class uses compound-based teaching materials while the experimental class does not use a compound intelligence-based teaching material. The instrument used is a test of understanding of the concept of global warming with multiple choices form amounted to 15 questions and 5 essay items. The test is given before and after it is applied to both classes. Data analysis using N-gain and effect size. The results obtained that the N-gain for both classes is in the medium category and the effectiveness of the use of teaching materials based on the results of effect-size test results obtained in the high category.

  12. Modifying ``Six Ideas that Shaped Physics'' for a Life-Science major audience at Hope College

    NASA Astrophysics Data System (ADS)

    Mader, Catherine

    2005-04-01

    The ``Six Ideas That Shaped Physics'' textbook has been adapted and used for use in the algebra-based introductory physics course for non-physics science majors at Hope College. The results of the first use will be presented. Comparison of FCI for pre and post test scores will be compared with results from 8 years of results from both the algebra-based course and the calculus-based course (when we first adopted ``Six Ideas that Shaped Physcs" for the Calculus-based course). In addition, comparison on quantitative tests and homework problems with prior student groups will also be made. Because a large fraction of the audience in the algebra-based course is life-science majors, a goal of this project is to make the material relevant for these students. Supplemental materials that emphasize the connection between the life sciences and the fundamental physics concepts are being be developed to accompany the new textbook. Samples of these materials and how they were used (and received) during class testing will be presented.

  13. Feasibility of supervised self-testing using an oral fluid-based HIV rapid testing method: a cross-sectional, mixed method study among pregnant women in rural India.

    PubMed

    Sarkar, Archana; Mburu, Gitau; Shivkumar, Poonam Varma; Sharma, Pankhuri; Campbell, Fiona; Behera, Jagannath; Dargan, Ritu; Mishra, Surendra Kumar; Mehra, Sunil

    2016-01-01

    HIV self-testing can increase coverage of essential HIV services. This study aimed to establish the acceptability, concordance and feasibility of supervised HIV self-testing among pregnant women in rural India. A cross-sectional, mixed methods study was conducted among 202 consenting pregnant women in a rural Indian hospital between August 2014 and January 2015. Participants were provided with instructions on how to self-test using OraQuick(®) HIV antibody test, and subsequently asked to self-test under supervision of a community health worker. Test results were confirmed at a government-run integrated counselling and testing centre. A questionnaire was used to obtain information on patient demographics and the ease, acceptability and difficulties of self-testing. In-depth interviews were conducted with a sub-sample of 35 participants to understand their experiences. In total, 202 participants performed the non-invasive, oral fluid-based, rapid test under supervision for HIV screening. Acceptance rate was 100%. Motivators for self-testing included: ease of testing (43.4%), quick results (27.3%) and non-invasive procedure (23.2%). Sensitivity and specificity were 100% for 201 tests, and one test was invalid. Concordance of test result interpretation between community health workers and participants was 98.5% with a Cohen's Kappa (k) value of k=0.566 with p<0.001 for inter-rater agreement. Although 92.6% participants reported that the instructions for the test were easy to understand, 18.7% required the assistance of a supervisor to self-test. Major themes that emerged from the qualitative interviews indicated the importance of the following factors in influencing acceptability of self-testing: clarity and accessibility of test instructions; time-efficiency and convenience of testing; non-invasiveness of the test; and fear of incorrect results. Overall, 96.5% of the participants recommended that the OraQuick(®) test kits should become publicly available. Self-testing for HIV status using an oral fluid-based rapid test under the supervision of a community health worker was acceptable and feasible among pregnant women in rural India. Participants were supportive of making self-testing publicly available. Policy guidelines and implementation research are required to advance HIV self-testing for larger populations at scale.

  14. A rapid multiplex PCR assay for presumptive species identification of rhinoceros horns and its implementation in Vietnam

    PubMed Central

    Frankham, Greta J.; McEwing, Ross; The, Dang Tat; Hogg, Carolyn J.; Lo, Nathan; Johnson, Rebecca N.

    2018-01-01

    Rhinoceros (rhinos) have suffered a dramatic increase in poaching over the past decade due to the growing demand for rhino horn products in Asia. One way to reverse this trend is to enhance enforcement and intelligence gathering tools used for species identification of horns, in particular making them fast, inexpensive and accurate. Traditionally, species identification tests are based on DNA sequence data, which, depending on laboratory resources, can be either time or cost prohibitive. This study presents a rapid rhino species identification test, utilizing species-specific primers within the cytochrome b gene multiplexed in a single reaction, with a presumptive species identification based on the length of the resultant amplicon. This multiplex PCR assay can provide a presumptive species identification result in less than 24 hours. Sequence-based definitive testing can be conducted if/when required (e.g. court purposes). This work also presents an actual casework scenario in which the presumptive test was successfully utlitised, in concert with sequence-based definitive testing. The test was carried out on seized suspected rhino horns tested at the Institute of Ecology and Biological Resources, the CITES mandated laboratory in Vietnam, a country that is known to be a major source of demand for rhino horns. This test represents the basis for which future ‘rapid species identification tests’ can be trialed. PMID:29902212

  15. Health-risk assessment based on an additive to paints made from isobutyric aldehyde condensation products

    NASA Astrophysics Data System (ADS)

    Jan Tic, Wilhelm

    2017-10-01

    Solvents are primarily used for making protective coatings. Considering their chemical nature, there are a great variety of coatings, including those based on liquid hydrocarbons and organic chloroderivatives. These products are a serious load to the environment because of their physicochemical properties, therefore, they have for some time been replaced with more-environmentally friendly, new generation products. One of them is the hydroxyester HE-1: made from isobutyric aldehyde condensation products, it is an alternative to those coalescents for paints and varnishes which are intended to be replaced or their use restricted. The results of selected toxicological tests relating to the human health risk effect of the hydroxyester HE-1 - environmentally-friendly additive to paints and varnishes are presented. The test results indicate that HE-1 causes skin irritation in rabbit only when used at its maximum concentrations. No lesions in the cornea or iris were observed in any of the test rabbits after the application of the hydroxyester HE-1. In the mutagenic effect test of HE-1 on the bacteria Salmonella typhimurium, the result was negative. Based on the test results, it was found that the hydroxyester HE-1 may only have a human health risk effect when used at its maximum concentrations.

  16. Population genetic testing for cancer susceptibility: founder mutations to genomes.

    PubMed

    Foulkes, William D; Knoppers, Bartha Maria; Turnbull, Clare

    2016-01-01

    The current standard model for identifying carriers of high-risk mutations in cancer-susceptibility genes (CSGs) generally involves a process that is not amenable to population-based testing: access to genetic tests is typically regulated by health-care providers on the basis of a labour-intensive assessment of an individual's personal and family history of cancer, with face-to-face genetic counselling performed before mutation testing. Several studies have shown that application of these selection criteria results in a substantial proportion of mutation carriers being missed. Population-based genetic testing has been proposed as an alternative approach to determining cancer susceptibility, and aims for a more-comprehensive detection of mutation carriers. Herein, we review the existing data on population-based genetic testing, and consider some of the barriers, pitfalls, and challenges related to the possible expansion of this approach. We consider mechanisms by which population-based genetic testing for cancer susceptibility could be delivered, and suggest how such genetic testing might be integrated into existing and emerging health-care structures. The existing models of genetic testing (including issues relating to informed consent) will very likely require considerable alteration if the potential benefits of population-based genetic testing are to be fully realized.

  17. Correlation between bithermal caloric test results and vestibular evoked myogenic potentials (VEMPs) in normal subjects.

    PubMed

    Andrade, Isabel Vaamonde Sanchez; Santos-Perez, Sofia; Diz, Pilar Gayoso; Caballero, Torcuato Labella; Soto-Varela, Andrés

    2013-05-01

    Bithermal caloric testing and vestibular evoked myogenic potentials (VEMPs) are both diagnostic tools for the study of the vestibular system. The first tests the horizontal semicircular canal and the second evaluates the saccule and lower vestibular nerve. The results of these two tests can therefore be expected to be correlated. The aim of this study was to compare bithermal caloric test results with VEMP records in normal subjects to verify whether they are correlated. A prospective study was conducted in 60 healthy subjects (30 men and 30 women) who underwent otoscopy, pure tone audiometry, bithermal caloric testing and VEMPs. From the caloric test, we assessed the presence of possible vestibular hypofunction, whether there was directional preponderance and reflectivity of each ear (all based on both slow phase velocity and nystagmus frequency). The analysed VEMPs variables were: p1 and n1 latency, corrected amplitude, interaural p1 latency difference and p1 interaural amplitude asymmetry. We compared the reflectivity, hypofunction and directional preponderance of the caloric tests with the corrected amplitudes and amplitude asymmetries of the VEMPs. No correlations were found in the different comparisons between bithermal caloric testing results and VEMPs except for a weak correlation (p = 0.039) when comparing preponderance based on the number of nystagmus in the caloric test and amplitude asymmetry with 99 dB tone burst in the VEMPs test. The results indicate that the two diagnostic tests are not comparable, so one of them cannot replace the other, but the use of both increases diagnostic success in some conditions.

  18. Translating expert system rules into Ada code with validation and verification

    NASA Technical Reports Server (NTRS)

    Becker, Lee; Duckworth, R. James; Green, Peter; Michalson, Bill; Gosselin, Dave; Nainani, Krishan; Pease, Adam

    1991-01-01

    The purpose of this ongoing research and development program is to develop software tools which enable the rapid development, upgrading, and maintenance of embedded real-time artificial intelligence systems. The goals of this phase of the research were to investigate the feasibility of developing software tools which automatically translate expert system rules into Ada code and develop methods for performing validation and verification testing of the resultant expert system. A prototype system was demonstrated which automatically translated rules from an Air Force expert system was demonstrated which detected errors in the execution of the resultant system. The method and prototype tools for converting AI representations into Ada code by converting the rules into Ada code modules and then linking them with an Activation Framework based run-time environment to form an executable load module are discussed. This method is based upon the use of Evidence Flow Graphs which are a data flow representation for intelligent systems. The development of prototype test generation and evaluation software which was used to test the resultant code is discussed. This testing was performed automatically using Monte-Carlo techniques based upon a constraint based description of the required performance for the system.

  19. Cognitive evaluation for the diagnosis of Alzheimer's disease based on Turing Test and Virtual Environments.

    PubMed

    Fernandez Montenegro, Juan Manuel; Argyriou, Vasileios

    2017-05-01

    Alzheimer's screening tests are commonly used by doctors to diagnose the patient's condition and stage as early as possible. Most of these tests are based on pen-paper interaction and do not embrace the advantages provided by new technologies. This paper proposes novel Alzheimer's screening tests based on virtual environments and game principles using new immersive technologies combined with advanced Human Computer Interaction (HCI) systems. These new tests are focused on the immersion of the patient in a virtual room, in order to mislead and deceive the patient's mind. In addition, we propose two novel variations of Turing Test proposed by Alan Turing as a method to detect dementia. As a result, four tests are introduced demonstrating the wide range of screening mechanisms that could be designed using virtual environments and game concepts. The proposed tests are focused on the evaluation of memory loss related to common objects, recent conversations and events; the diagnosis of problems in expressing and understanding language; the ability to recognize abnormalities; and to differentiate between virtual worlds and reality, or humans and machines. The proposed screening tests were evaluated and tested using both patients and healthy adults in a comparative study with state-of-the-art Alzheimer's screening tests. The results show the capacity of the new tests to distinguish healthy people from Alzheimer's patients. Copyright © 2017. Published by Elsevier Inc.

  20. A detailed numerical simulation of a liquid-propellant rocket engine ground test experiment

    NASA Astrophysics Data System (ADS)

    Lankford, D. W.; Simmons, M. A.; Heikkinen, B. D.

    1992-07-01

    A computational simulation of a Liquid Rocket Engine (LRE) ground test experiment was performed using two modeling approaches. The results of the models were compared with selected data to assess the validity of state-of-the-art computational tools for predicting the flowfield and radiative transfer in complex flow environments. The data used for comparison consisted of in-band station radiation measurements obtained in the near-field portion of the plume exhaust. The test article was a subscale LRE with an afterbody, resulting in a large base region. The flight conditions were such that afterburning regions were observed in the plume flowfield. A conventional standard modeling approach underpredicted the extent of afterburning and the associated radiation levels. These results were attributed to the absence of the base flow region which is not accounted for in this model. To assess the effects of the base region a Navier-Stokes model was applied. The results of this calculation indicate that the base recirculation effects are dominant features in the immediate expansion region and resulted in a much improved comparison. However, the downstream in-band station radiation data remained underpredicted by this model.

  1. Construction and validation of a population-based bone densitometry database.

    PubMed

    Leslie, William D; Caetano, Patricia A; Macwilliam, Leonard R; Finlayson, Gregory S

    2005-01-01

    Utilization of dual-energy X-ray absorptiometry (DXA) for the initial diagnostic assessment of osteoporosis and in monitoring treatment has risen dramatically in recent years. Population-based studies of the impact of DXA and osteoporosis remain challenging because of incomplete and fragmented test data that exist in most regions. Our aim was to create and assess completeness of a database of all clinical DXA services and test results for the province of Manitoba, Canada and to present descriptive data resulting from testing. A regionally based bone density program for the province of Manitoba, Canada was established in 1997. Subsequent DXA services were prospectively captured in a program database. This database was retrospectively populated with earlier DXA results dating back to 1990 (the year that the first DXA scanner was installed) by integrating multiple data sources. A random chart audit was performed to assess completeness and accuracy of this dataset. For comparison, testing rates determined from the DXA database were compared with physician administrative claims data. There was a high level of completeness of this database (>99%) and accurate personal identifier information sufficient for linkage with other health care administrative data (>99%). This contrasted with physician billing data that were found to be markedly incomplete. Descriptive data provide a profile of individuals receiving DXA and their test results. In conclusion, the Manitoba bone density database has great potential as a resource for clinical and health policy research because it is population based with a high level of completeness and accuracy.

  2. The Design and Development of a Context-Rich, Photo-Based Online Testing to Assess Students' Science Learning

    ERIC Educational Resources Information Center

    Lin, Min-Jin; Guo, Chorng-Jee; Hsu, Chia-Er

    2011-01-01

    This study designed and developed a CP-MCT (content-rich, photo-based multiple choice online test) to assess whether college students can apply the basic light concept to interpret daily light phenomena. One hundred college students volunteered to take the CP-MCT, and the results were statistically analyzed by applying t-test or ANOVA (Analysis of…

  3. Motion-base simulator results of advanced supersonic transport handling qualities with active controls

    NASA Technical Reports Server (NTRS)

    Feather, J. B.; Joshi, D. S.

    1981-01-01

    Handling qualities of the unaugmented advanced supersonic transport (AST) are deficient in the low-speed, landing approach regime. Consequently, improvement in handling with active control augmentation systems has been achieved using implicit model-following techniques. Extensive fixed-based simulator evaluations were used to validate these systems prior to tests with full motion and visual capabilities on a six-axis motion-base simulator (MBS). These tests compared the handling qualities of the unaugmented AST with several augmented configurations to ascertain the effectiveness of these systems. Cooper-Harper ratings, tracking errors, and control activity data from the MBS tests have been analyzed statistically. The results show the fully augmented AST handling qualities have been improved to an acceptable level.

  4. ERS technical standard on bronchial challenge testing: general considerations and performance of methacholine challenge tests.

    PubMed

    Coates, Allan L; Wanger, Jack; Cockcroft, Donald W; Culver, Bruce H; Diamant, Zuzana; Gauvreau, Gail; Hall, Graham L; Hallstrand, Teal S; Horvath, Ildiko; de Jongh, Frans H C; Joos, Guy; Kaminsky, David A; Laube, Beth L; Leuppi, Joerg D; Sterk, Peter J

    2017-05-01

    This international task force report updates general considerations for bronchial challenge testing and the performance of the methacholine challenge test. There are notable changes from prior recommendations in order to accommodate newer delivery devices. Rather than basing the test result upon a methacholine concentration (provocative concentration (PC 20 ) causing a 20% fall in forced expiratory volume in 1 s (FEV 1 )), the new recommendations base the result upon the delivered dose of methacholine causing a 20% fall in FEV 1 (provocative dose (PD 20 )). This end-point allows comparable results from different devices or protocols, thus any suitable nebuliser or dosimeter may be used, so long as the delivery characteristics are known. Inhalation may be by tidal breathing using a breath-actuated or continuous nebuliser for 1 min (or more), or by a dosimeter with a suitable breath count. Tests requiring maximal inhalations to total lung capacity are not recommended because the bronchoprotective effect of a deep breath reduces the sensitivity of the test. Copyright ©ERS 2017.

  5. Design and test of an automated version of the modified Jebsen test of hand function using Microsoft Kinect.

    PubMed

    Simonsen, Daniel; Nielsen, Ida F; Spaich, Erika G; Andersen, Ole K

    2017-05-02

    The present paper describes the design and evaluation of an automated version of the Modified Jebsen Test of Hand Function (MJT) based on the Microsoft Kinect sensor. The MJT was administered twice to 11 chronic stroke subjects with varying degrees of hand function deficits. The test times of the MJT were evaluated manually by a therapist using a stopwatch, and automatically using the Microsoft Kinect sensor. The ground truth times were assessed based on inspection of the video-recordings. The agreement between the methods was evaluated along with the test-retest performance. The results from Bland-Altman analysis showed better agreement between the ground truth times and the automatic MJT time evaluations compared to the agreement between the ground truth times and the times estimated by the therapist. The results from the test-retest performance showed that the subjects significantly improved their performance in several subtests of the MJT, indicating a practice effect. The results from the test showed that the Kinect can be used for automating the MJT.

  6. Avoiding Split Attention in Computer-Based Testing: Is Neglecting Additional Information Facilitative?

    ERIC Educational Resources Information Center

    Jarodzka, Halszka; Janssen, Noortje; Kirschner, Paul A.; Erkens, Gijsbert

    2015-01-01

    This study investigated whether design guidelines for computer-based learning can be applied to computer-based testing (CBT). Twenty-two students completed a CBT exam with half of the questions presented in a split-screen format that was analogous to the original paper-and-pencil version and half in an integrated format. Results show that students…

  7. USB environment measurements based on full-scale static engine ground tests

    NASA Technical Reports Server (NTRS)

    Sussman, M. B.; Harkonen, D. L.; Reed, J. B.

    1976-01-01

    Flow turning parameters, static pressures, surface temperatures, surface fluctuating pressures and acceleration levels were measured in the environment of a full-scale upper surface blowing (USB) propulsive lift test configuration. The test components included a flightworthy CF6-50D engine, nacelle, and USB flap assembly utilized in conjunction with ground verification testing of the USAF YC-14 Advanced Medium STOL Transport propulsion system. Results, based on a preliminary analysis of the data, generally show reasonable agreement with predicted levels based on model data. However, additional detailed analysis is required to confirm the preliminary evaluation, to help delineate certain discrepancies with model data, and to establish a basis for future flight test comparisons.

  8. Hydrostratigraphic interpretation of test-hole and surface geophysical data, Elkhorn and Loup River Basins, Nebraska, 2008 to 2011

    USGS Publications Warehouse

    Hobza, Christopher M.; Bedrosian, Paul A.; Bloss, Benjamin R.

    2012-01-01

    The Elkhorn-Loup Model (ELM) was begun in 2006 to understand the effect of various groundwater-management scenarios on surface-water resources. During phase one of the ELM study, a lack of subsurface geological information was identified as a data gap. Test holes drilled to the base of the aquifer in the ELM study area are spaced as much as 25 miles apart, especially in areas of the western Sand Hills. Given the variable character of the hydrostratigraphic units that compose the High Plains aquifer system, substantial variation in aquifer thickness and characteristics can exist between test holes. To improve the hydrogeologic understanding of the ELM study area, the U.S. Geological Survey, in cooperation with the Nebraska Department of Natural Resources, multiple Natural Resources Districts participating in the ELM study, and the University of Nebraska-Lincoln Conservation and Survey Division, described the subsurface lithology at six test holes drilled in 2010 and concurrently collected borehole geophysical data to identify the base of the High Plains aquifer system. A total of 124 time-domain electromagnetic (TDEM) soundings of resistivity were collected at and between selected test-hole locations during 2008-11 as a quick, non-invasive means of identifying the base of the High Plains aquifer system. Test-hole drilling and geophysical logging indicated the base-of-aquifer elevation was less variable in the central ELM area than in previously reported results from the western part of the ELM study area, where deeper paleochannels were eroded into the Brule Formation. In total, more than 435 test holes were examined and compared with the modeled-TDEM soundings. Even where present, individual stratigraphic units could not always be identified in modeled-TDEM sounding results if sufficient resistivity contrast was not evident; however, in general, the base of aquifer [top of the aquifer confining unit (ACU)] is one of the best-resolved results from the TDEM-based models, and estimates of the base-of-aquifer elevation are in good accordance with those from existing test-hole data. Differences between ACU elevations based on modeled-TDEM and test-hole data ranged from 2 to 113 feet (0.6 to 34 meters). The modeled resistivity results reflect the eastward thinning of Miocene-age and older stratigraphic units, and generally allowed confident identification of the accompanying change in the stratigraphic unit forming the ACU. The differences in elevation of the top of the Ogallala, estimated on the basis of the modeled-TDEM resistivity, and the test-hole data ranged from 11 to 251 feet (3.4 to 77 meters), with two-thirds of model results being within 60 feet of the test-hole contact elevation. The modeled-TDEM soundings also provided information regarding the distribution of Plio-Pleistocene gravel deposits, which had an average thickness of 100 feet (30 meters) in the study area; however, in many cases the contact between the Plio-Pleistocene deposits and the overlying Quaternary deposits cannot be reliably distinguished using TDEM soundings alone because of insufficient thickness or resistivity contrast.

  9. CHARACTERIZATION OF AEROSOLS FROM A WATER-BASED CLEANER APPLIED WITH A HAND-PUMP SPRAYER

    EPA Science Inventory

    The paper gives results of tests that were performed in a controlled-environment test room to measure particle concentrations and size distributions and concentrations of selected volatily organic compounds during, and following, application of water-based cleaners to realistic s...

  10. Mitigating Upsets in SRAM Based FPGAs from the Xilinix Virtex 2 Family

    NASA Technical Reports Server (NTRS)

    Swift, Gary M.; Yui, Candice C.; Carmichael, Carl; Koga, Rocky; George, Jeffrey S.

    2003-01-01

    This slide presentation reviews the single event upset static testing of the Virtex II field programmable gate arrays (FPGA) that were tested in protons and heavy-ions. The test designs and static and dynamic test results are reviewed.

  11. Fatigue crack identification method based on strain amplitude changing

    NASA Astrophysics Data System (ADS)

    Guo, Tiancai; Gao, Jun; Wang, Yonghong; Xu, Youliang

    2017-09-01

    Aiming at the difficulties in identifying the location and time of crack initiation in the castings of helicopter transmission system during fatigue tests, by introducing the classification diagnostic criteria of similar failure mode to find out the similarity of fatigue crack initiation among castings, an engineering method and quantitative criterion for detecting fatigue cracks based on strain amplitude changing is proposed. This method is applied on the fatigue test of a gearbox housing, whose results indicates: during the fatigue test, the system alarms when SC strain meter reaches the quantitative criterion. The afterwards check shows that a fatigue crack less than 5mm is found at the corresponding location of SC strain meter. The test result proves that the method can provide accurate test data for strength life analysis.

  12. Report of Results Tutorial Reading Project, Indianapolis Public Schools, 1968-1969.

    ERIC Educational Resources Information Center

    Ellson, D. G.

    The results of testing some 1,265 first-grade students who took part in the Tutorial Reading Project for the full 1968-69 school year in Indianapolis are reported. Subjects were selected from the lower third of the first grade, based on Metropolitan Reading Readiness Test scores and teachers' judgments. Separate pretesting and post-testing was…

  13. Papers Based Electrochemical Biosensors: From Test Strips to Paper-Based Microfluidics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Bingwen; Du, Dan; Hua, Xin

    2014-05-08

    Papers based biosensors such as lateral flow test strips and paper-based microfluidic devices (or paperfluidics) are inexpensive, rapid, flexible, and easy-to-use analytical tools. An apparent trend in their detection is to interpret sensing results from qualitative assessment to quantitative determination. Electrochemical detection plays an important role in quantification. This review focuses on electrochemical (EC) detection enabled biosensors. The first part provides detailed examples in paper test strips. The second part gives an overview of paperfluidics engaging EC detections. The outlook and recommendation of future directions of EC enabled biosensors are discussed in the end.

  14. A study to ascertain the viability of ultrasonic nondestructive testing to determine the mechanical characteristics of wood/agricultural hardboards with soybean based adhesives

    NASA Astrophysics Data System (ADS)

    Colen, Charles Raymond, Jr.

    There have been numerous studies with ultrasonic nondestructive testing and wood fiber composites. The problem of the study was to ascertain whether ultrasonic nondestructive testing can be used in place of destructive testing to obtain the modulus of elasticity (MOE) of the wood/agricultural material with comparable results. The uniqueness of this research is that it addressed the type of content (cornstalks and switchgrass) being used with the wood fibers and the type of adhesives (soybean-based) associated with the production of these composite materials. Two research questions were addressed in the study. The major objective was to determine if one can predict the destructive test MOE value based on the nondestructive test MOE value. The population of the study was wood/agricultural fiberboards made from wood fibers, cornstalks, and switchgrass bonded together with soybean-based, urea-formaldehyde, and phenol-formaldehyde adhesives. Correlational analysis was used to determine if there was a relationship between the two tests. Regression analysis was performed to determine a prediction equation for the destructive test MOE value. Data were collected on both procedures using ultrasonic nondestructing testing and 3-point destructive testing. The results produced a simple linear regression model for this study which was adequate in the prediction of destructive MOE values if the nondestructive MOE value is known. An approximation very close to the entire error in the model equation was explained from the destructive test MOE values for the composites. The nondestructive MOE values used to produce a linear regression model explained 83% of the variability in the destructive test MOE values. The study also showed that, for the particular destructive test values obtained with the equipment used, the model associated with the study is as good as it could be due to the variability in the results from the destructive tests. In this study, an ultrasonic signal was used to determine the MOE values on nondestructive tests. Future research studies could use the same or other hardboards to examine how the resins affect the ultrasonic signal.

  15. [Increase in orders for specific IgE tests and more positive results in children in 1985-2003].

    PubMed

    Baatenburg de Jong, A; Dikkeschei, L D; Brand, P L P

    2008-08-09

    To describe changes over time in the number of allergy tests for specific IgE ordered and outcomes in children, to help address the question whether the increase in allergies is due to an actual increase in sensitisation or an increase in diagnostic awareness of allergies among physicians. Retrospective and descriptive. We reviewed the results of all specific IgE tests performed in our hospital's laboratory for children 0-18 years of age in the period 1985-2003. This included tests ordered by both general practitioners and hospital-based specialists. We analysed trends over time in the number of tests ordered (as an indicator ofdiagnostic awareness) and test results (as an indicator ofsensitisation). Between 1989 and 1995, the annual number of tests ordered increased from 1 per 10,000 children to 95 per 10,000 children and remained stable thereafter. Before 1990, more than 90% of tests were ordered by hospital-based specialists; after 1990, approximately 70% of the tests were ordered by general practitioners (p < 0.001). The proportion of positive tests remained stable at approximately 27% until 1991, after which it increased to more than 45% (p < 0.001). The increase in the proportion of positive tests suggests an increase in atopic sensitization between 1985 and 2000 which has stabilized since.

  16. Active-learning versus teacher-centered instruction for learning acids and bases

    NASA Astrophysics Data System (ADS)

    Acar Sesen, Burcin; Tarhan, Leman

    2011-07-01

    Background and purpose: Active-learning as a student-centered learning process has begun to take more interest in constructing scientific knowledge. For this reason, this study aimed to investigate the effectiveness of active-learning implementation on high-school students' understanding of 'acids and bases'. Sample The sample of this study was 45 high-school students (average age 17 years) from two different classes, which were randomly assigned to the experimental (n = 21) and control groups (n = 25), in a high school in Turkey. Design and methods A pre-test consisting of 25 items was applied to both experimental and control groups before the treatment in order to identify student prerequisite knowledge about their proficiency for learning 'acids and bases'. A one-way analysis of variance (ANOVA) was conducted to compare the pre-test scores for groups and no significant difference was found between experimental (ME = 40.14) and control groups (MC = 41.92) in terms of mean scores (F 1,43 = 2.66, p > 0.05). The experimental group was taught using an active-learning curriculum developed by the authors and the control group was taught using traditional course content based on teacher-centered instruction. After the implementation, 'Acids and Bases Achievement Test' scores were collected for both groups. Results ANOVA results showed that students' 'Acids and Bases Achievement Test' post-test scores differed significantly in terms of groups (F 1,43 = 102.53; p < 0.05). Additionally, in this study 54 misconceptions, 14 of them not reported in the literature before, were observed in the following terms: 'acid and base theories'; 'metal and non-metal oxides'; 'acid and base strengths'; 'neutralization'; 'pH and pOH'; 'hydrolysis'; 'acid-base equilibrium'; 'buffers'; 'indicators'; and 'titration'. Based on the achievement test and individual interview results, it was found that high-school students in the experimental group had fewer misconceptions and understood the concepts more meaningfully than students in control group. Conclusion The study revealed that active-learning implementation is more effective at improving students' learning achievement and preventing misconceptions.

  17. Cryocooler based test setup for high current applications

    NASA Astrophysics Data System (ADS)

    Pradhan, Jedidiah; Das, Nisith Kr.; Roy, Anindya; Duttagupta, Anjan

    2018-04-01

    A cryo-cooler based cryogenic test setup has been designed, fabricated, and tested. The setup incorporates two numbers of cryo-coolers, one for sample cooling and the other one for cooling the large magnet coil. The performance and versatility of the setup has been tested using large samples of high-temperature superconductor magnet coil as well as short samples with high current. Several un-calibrated temperature sensors have been calibrated using this system. This paper presents the details of the system along with results of different performance tests.

  18. Self-testing produces superior recall of both familiar and unfamiliar muscle information.

    PubMed

    Dobson, John L; Linderholm, Tracy; Yarbrough, Mary Beth

    2015-12-01

    Dozens of studies have found learning strategies based on the "testing effect" promote greater recall than those that rely solely on reading; however, the advantages of testing are often only observed after a delay (e.g., 2-7 days later). In contrast, our research, which has focused on kinesiology students learning kinesiology information that is generally familiar to them, has consistently demonstrated that testing-based strategies produce greater recall both immediately and after a delay. In an attempt to understand the discrepancies in the literature, the purpose of the present study was to determine if the time-related advantages of a testing-based learning strategy vary with one's familiarity with the to-be-learned information. Participants used both read-only and testing-based strategies to repeatedly study three different sets of information: 1) previously studied human muscle information (familiar information), 2) a mix of previously studied and previously unstudied human muscle information (mixed information), and 3) previously unstudied muscle information that is unique to sharks (unfamiliar information). Learning was evaluated via free recall assessments administered immediately after studying and again after a 1-wk delay and a 3-wk delay. Across those three assessments, the read-only strategy resulted in mean scores of 29.26 ± 1.43, 15.17 ± 1.29, and 5.33 ± 0.77 for the familiar, mixed, and unfamiliar information, respectively, whereas the testing-based strategy produced scores of 34.57 ± 1.58, 16.90 ± 1.31, and 8.33 ± 0.95, respectively. The results indicate that the testing-based strategy produced greater recall immediately and up through the 3-wk delay regardless of the participants' level of familiarity with the muscle information. Copyright © 2015 The American Physiological Society.

  19. TEXSYS. [a knowledge based system for the Space Station Freedom thermal control system test-bed

    NASA Technical Reports Server (NTRS)

    Bull, John

    1990-01-01

    The Systems Autonomy Demonstration Project has recently completed a major test and evaluation of TEXSYS, a knowledge-based system (KBS) which demonstrates real-time control and FDIR for the Space Station Freedom thermal control system test-bed. TEXSYS is the largest KBS ever developed by NASA and offers a unique opportunity for the study of technical issues associated with the use of advanced KBS concepts including: model-based reasoning and diagnosis, quantitative and qualitative reasoning, integrated use of model-based and rule-based representations, temporal reasoning, and scale-up performance issues. TEXSYS represents a major achievement in advanced automation that has the potential to significantly influence Space Station Freedom's design for the thermal control system. An overview of the Systems Autonomy Demonstration Project, the thermal control system test-bed, the TEXSYS architecture, preliminary test results, and thermal domain expert feedback are presented.

  20. Video- or text-based e-learning when teaching clinical procedures? A randomized controlled trial

    PubMed Central

    Buch, Steen Vigh; Treschow, Frederik Philip; Svendsen, Jesper Brink; Worm, Bjarne Skjødt

    2014-01-01

    Background and aims This study investigated the effectiveness of two different levels of e-learning when teaching clinical skills to medical students. Materials and methods Sixty medical students were included and randomized into two comparable groups. The groups were given either a video- or text/picture-based e-learning module and subsequently underwent both theoretical and practical examination. A follow-up test was performed 1 month later. Results The students in the video group performed better than the illustrated text-based group in the practical examination, both in the primary test (P<0.001) and in the follow-up test (P<0.01). Regarding theoretical knowledge, no differences were found between the groups on the primary test, though the video group performed better on the follow-up test (P=0.04). Conclusion Video-based e-learning is superior to illustrated text-based e-learning when teaching certain practical clinical skills. PMID:25152638

  1. The development and preliminary testing of a multimedia patient–provider survivorship communication module for breast cancer survivors

    PubMed Central

    Wen, Kuang-Yi; Miller, Suzanne M.; Stanton, Annette L.; Fleisher, Linda; Morra, Marion E.; Jorge, Alexandra; Diefenbach, Michael A.; Ropka, Mary E.; Marcus, Alfred C.

    2012-01-01

    Objective This paper describes the development of a theory-guided and evidence-based multimedia training module to facilitate breast cancer survivors’ preparedness for effective communication with their health care providers after active treatment. Methods The iterative developmental process used included: (1) theory and evidence-based content development and vetting; (2) user testing; (3) usability testing; and (4) participant module utilization. Results Formative evaluation of the training module prototype occurred through user testing (n = 12), resulting in modification of the content and layout. Usability testing (n = 10) was employed to improve module functionality. Preliminary web usage data (n = 256, mean age = 53, 94.5% White, 75% college graduate and above) showed that 59% of the participants accessed the communication module, for an average of 7 min per login. Conclusion The iterative developmental process was informative in enhancing the relevance of the communication module. Preliminary web usage results demonstrate the potential feasibility of such a program. Practice implications Our study demonstrates survivors’ openness to the use of a web-based communication skills training module and outlines a systematic iterative user and interface program development and testing process, which can serve as a prototype for others considering such an approach. PMID:22770812

  2. The effect of physics-based scientific learning on the improvement of the student’s critical thinking skills

    NASA Astrophysics Data System (ADS)

    Zaidah, A.; Sukarmin; Sunarno, W.

    2018-04-01

    This study aimed to determine the influence of a physics-based scientific learning to increase student’s critical thinking skill. This type of this research was quantitative research with taking the conclusion through statistical analysis. This research was carried out in MA (Senior High School) Mu'allimat NW Pancor in the second semester in the academic year of 2016/2017 with all students of XI class. The sampling is done by using technique purposive sampling where the class was taken from XI 6 class. Based on the result of descriptive analysis, it was obtained an average pre-test score of 49.17 and an average post-test score of 82.43. Also, the results showed that the average score was gained of 0.67 with a medium category. Based on the inferential analysis showed the value of t = 22.559 while the ttable in significance level of 5% was 2.04. Thus, t > the ttable from Ha is accepted. Therefore, the pre-test and posttest were different significantly when the students used scientific-based learning. The result showed that a physics-based scientific learning has influenced to increase the student’s critical thinking skill.

  3. Treatment Option Overview (Breast Cancer)

    MedlinePlus

    ... using a thin needle. If cancer is found, tests are done to study the cancer cells. Decisions about the best treatment are based on the results of these tests. The tests give information about: how quickly the ...

  4. Treatment Options for Male Breast Cancer

    MedlinePlus

    ... entire lump of tissue. If cancer is found, tests are done to study the cancer cells. Decisions about the best treatment are based on the results of these tests. The tests give information about: How quickly the ...

  5. Treatment Option Overview (Male Breast Cancer)

    MedlinePlus

    ... entire lump of tissue. If cancer is found, tests are done to study the cancer cells. Decisions about the best treatment are based on the results of these tests. The tests give information about: How quickly the ...

  6. Stages of Male Breast Cancer

    MedlinePlus

    ... entire lump of tissue. If cancer is found, tests are done to study the cancer cells. Decisions about the best treatment are based on the results of these tests. The tests give information about: How quickly the ...

  7. Reuse of Boron Waste as an Additive in Road Base Material

    PubMed Central

    Zhang, Yutong; Guo, Qinglin; Li, Lili; Jiang, Ping; Jiao, Yubo; Cheng, Yongchun

    2016-01-01

    The amount of boron waste increases year by year. There is an urgent demand to manage it in order to reduce the environmental impact. In this paper, boron waste was reused as an additive in road base material. Lime and cement were employed to stabilize the waste mixture. Mechanical performances of stabilized mixture were evaluated by experimental methods. A compaction test, an unconfined compressive test, an indirect tensile test, a modulus test, a drying shrinkage test, and a frost resistance test were carried out. Results indicated that mechanical strengths of lime-stabilized boron waste mixture (LSB) satisfy the requirements of road base when lime content is greater than 8%. LSB can only be applied in non-frozen regions as a result of its poor frost resistance. The lime–cement-stabilized mixture can be used in frozen regions when lime and cement contents are 8% and 5%, respectively. Aggregate reduces the drying shrinkage coefficient effectively. Thus, aggregate is suggested for mixture stabilization properly. This work provides a proposal for the management of boron waste. PMID:28773539

  8. Collaborative study for the standardisation of the histamine sensitizing test in mice and the CHO cell-based assay for the residual toxicity testing of acellular pertussis vaccines.

    PubMed

    Xing, D; Maes, A; Behr-Gross, M-E; Costanzo, A; Daas, A; Buchheit, K-H

    2010-04-01

    The European Pharmacopoeia (Ph. Eur.) and the World Health Organisation (WHO) require the performance of extensive quality and safety control testing before the release on the market of vaccine products for human use. Safety testing with regard to residual pertussis toxin (PT) in acellular pertussis combination vaccines is performed through assessment of fatal sensitisation of mice to histamine challenge by the vaccine product under test. Currently, use of different in-house procedures and no requirement for the inclusion of a standard reference in each assay render comparisons of results obtained for identical vaccine batches between different control laboratories very difficult. At the initiative of the European Directorate for the Quality of Medicines and HealthCare (EDQM), an international collaborative study was organised for the standardization of the Histamine Sensitizing Test (HIST) in mice and the Chinese Hamster Ovary (CHO)-cell-based assay (performed at the bulk product level) for the residual toxicity testing of acellular pertussis vaccines or acellular pertussis-based combination vaccines. The study was run under the aegis of the Biological Standardisation Programme, jointly supported by the Council of Europe and the European Commission under the project code BSP076. Ten (10) laboratories participated in the study and were requested to perform 3 independent Histamine Sensitizing Tests in mice and to report results of the lethal end-point measurement as prescribed by the Ph. Eur. monographs. Some of them also reported data from an in-house validated CHO-cell-based assay. In addition, some of the laboratories reported concomitantly data obtained by measurement of the drop in temperature induced after the histamine challenge, a method currently under investigation to be added as an alternative end-point for the HIST in the Ph. Eur. monographs for acellular pertussis-based combination vaccines in order to alleviate animal suffering (in application of the 3Rs principle). Based on the results of the collaborative study, a potency of 7500 IU/vial (International Units per vial) was assigned to the current Ph. Eur. Biological Reference Preparation (BRP) for PT. The results of the study also show that 1) intra- and inter-laboratory variations can be improved by the use of a validated standard operating procedure; 2) inclusion in each assay of a standard reference sample, calibrated in IU, can increase comparability of results among laboratories and thus help to reduce repeat testing; 3) a correlation between mortality data and temperature data was observed although, due to the limited number of data sets and the lack of a common method for the temperature end-point, further investigation of this point is required; 4) the CHO-cell-based assay did not yield comparable results and further standardisation of the assay procedure may be investigated in a follow-up project.

  9. Vibration Modal Characterization of a Stirling Convertor via Base-Shake Excitation

    NASA Technical Reports Server (NTRS)

    Suarez, Vicente J.; Goodnight, Thomas W.; Hughes, William O.; Samorezov, Sergey

    2003-01-01

    The U.S. Department of Energy (DOE), Lockheed Martin (LM), Stirling Technology Company (STC), and NASA John H. Glenn Research Center (GRC) are currently developing a high-efficiency Stirling convertor for use in a Stirling Radioisotope Generator (SRG). NASA and DOE have identified the SRG for potential use as an advanced power system for future NASA Space Science missions, providing spacecraft onboard electric power for deep space missions and power for unmanned Mars rovers. Low-level, baseshake sine vibration tests were conducted on the Stirling Technology Demonstration Convertor (TDC), at NASA GRC's Structural Dynamics Laboratory, in February 2001, as part of the development of this Stirling technology. The purpose of these tests was to provide a better understanding of the TDC's internal dynamic response to external vibratory base excitations. The knowledge obtained can therein be used to help explain the success that the TDC enjoyed in its previous random vibration qualification tests (December 1999). This explanation focuses on the TDC s internal dynamic characteristics in the 50 to 250 Hz frequency range, which corresponds to the maximum input levels of its qualification random vibration test specification. The internal dynamic structural characteristics of the TDC have now been measured in two separate tests under different motoring and dynamic loading conditions: (1) with the convertor being electrically motored, under a vibratory base-shake excitation load, and (2) with the convertor turned off, and its alternator internals undergoing dynamic excitation via hammer impact loading. This paper addresses the test setup, procedure and results of the base-shake vibration testing conducted on the motored TDC, and will compare these results with those results obtained from the dynamic impact tests (May 2001) on the nonmotored TDC.

  10. Logistical Consideration in Computer-Based Screening of Astronaut Applicants

    NASA Technical Reports Server (NTRS)

    Galarza, Laura

    2000-01-01

    This presentation reviews the logistical, ergonomic, and psychometric issues and data related to the development and operational use of a computer-based system for the psychological screening of astronaut applicants. The Behavioral Health and Performance Group (BHPG) at the Johnson Space Center upgraded its astronaut psychological screening and selection procedures for the 1999 astronaut applicants and subsequent astronaut selection cycles. The questionnaires, tests, and inventories were upgraded from a paper-and-pencil system to a computer-based system. Members of the BHPG and a computer programmer designed and developed needed interfaces (screens, buttons, etc.) and programs for the astronaut psychological assessment system. This intranet-based system included the user-friendly computer-based administration of tests, test scoring, generation of reports, the integration of test administration and test output to a single system, and a complete database for past, present, and future selection data. Upon completion of the system development phase, four beta and usability tests were conducted with the newly developed system. The first three tests included 1 to 3 participants each. The final system test was conducted with 23 participants tested simultaneously. Usability and ergonomic data were collected from the system (beta) test participants and from 1999 astronaut applicants who volunteered the information in exchange for anonymity. Beta and usability test data were analyzed to examine operational, ergonomic, programming, test administration and scoring issues related to computer-based testing. Results showed a preference for computer-based testing over paper-and -pencil procedures. The data also reflected specific ergonomic, usability, psychometric, and logistical concerns that should be taken into account in future selection cycles. Conclusion. Psychological, psychometric, human and logistical factors must be examined and considered carefully when developing and using a computer-based system for psychological screening and selection.

  11. Evaluation of mechanical properties of Aluminum-Copper cold sprayed and alloy 625 wire arc sprayed coatings

    NASA Astrophysics Data System (ADS)

    Bashirzadeh, Milad

    This study examines microstructural-based mechanical properties of Al-Cu composite deposited by cold spraying and wire arc sprayed nickel-based alloy 625 coating using numerical modeling and experimental techniques. The microhardness and elastic modulus of samples were determined using the Knoop hardness technique. Hardness in both transverse and longitudinal directions on the sample cross-sections has been measured. An image-based finite element simulation algorithm was employed to determine the mechanical properties through an inverse analysis. In addition mechanical tests including, tensile, bending, and nano-indentation tests were performed on alloy 625 wire arc sprayed samples. Overall, results from the experimental tests are in relatively good agreement for deposited Al-Cu composites and alloy 625 coating. However, results obtained from numerical simulation are significantly higher in value than experimentally obtained results. Examination and comparison of the results are strong indications of the influence of microstructure characteristics on the mechanical properties of thermally spray deposited coatings.

  12. Returning HIV-1 viral load results to participant-selected health facilities in national Population-based HIV Impact Assessment (PHIA) household surveys in three sub-Saharan African Countries, 2015 to 2016.

    PubMed

    Saito, Suzue; Duong, Yen T; Metz, Melissa; Lee, Kiwon; Patel, Hetal; Sleeman, Katrina; Manjengwa, Julius; Ogollah, Francis M; Kasongo, Webster; Mitchell, Rick; Mugurungi, Owen; Chimbwandira, Frank; Moyo, Crispin; Maliwa, Vusumuzi; Mtengo, Helecks; Nkumbula, Tepa; Ndongmo, Clement B; Vere, Nora Skutayi; Chipungu, Geoffrey; Parekh, Bharat S; Justman, Jessica; Voetsch, Andrew C

    2017-11-01

    Logistical complexities of returning laboratory test results to participants have precluded most population-based HIV surveys conducted in sub-Saharan Africa from doing so. For HIV positive participants, this presents a missed opportunity for engagement into clinical care and improvement in health outcomes. The Population-based HIV Impact Assessment (PHIA) surveys, which measure HIV incidence and the prevalence of viral load (VL) suppression in selected African countries, are returning VL results to health facilities specified by each HIV positive participant within eight weeks of collection. We describe the performance of the specimen and data management systems used to return VL results to PHIA participants in Zimbabwe, Malawi and Zambia. Consenting participants underwent home-based counseling and HIV rapid testing as per national testing guidelines; all confirmed HIV positive participants had VL measured at a central laboratory on either the Roche CAP/CTM or Abbott m2000 platform. On a bi-weekly basis, a dedicated data management team produced logs linking the VL test result with the participants' contact information and preferred health facility; project staff sent test results confidentially via project drivers, national courier systems, or electronically through an adapted short message service (SMS). Participants who provided cell phone numbers received SMS or phone call alerts regarding availability of VL results. From 29,634 households across the three countries, 78,090 total participants 0 to 64 years in Zimbabwe and Malawi and 0 to 59 years in Zambia underwent blood draw and HIV testing. Of the 8391 total HIV positive participants identified, 8313 (99%) had VL tests performed and 8245 (99%) of these were returned to the selected health facilities. Of the 5979 VL results returned in Zimbabwe and Zambia, 85% were returned within the eight-week goal with a median turnaround time of 48 days (IQR: 33 to 61). In Malawi, where exact return dates were unavailable all 2266 returnable results reached the health facilities by 11 weeks. The first three PHIA surveys returned the vast majority of VL results to each HIV positive participant's preferred health facility within the eight-week target. Even in the absence of national VL monitoring systems, a system to return VL results from a population-based survey is feasible, but it requires developing laboratory and data management systems and dedicated staff. These are likely important requirements to strengthen return of results systems in routine clinical care. © 2017 The Authors. Journal of the International AIDS Society published by John Wiley & sons Ltd on behalf of the International AIDS Society.

  13. A smartphone-based system for the automated management of point-of-care test results in hospitals.

    PubMed

    Jang, Dasom; Shin, Soo-Yong; Seo, Dong-Woo; Joo, Segyeong; Huh, Soo-Jin

    2015-04-01

    Managing test results is an important issue in hospitals because of the increasing use of point-of-care testing (POCT). Here, we propose a smartphone-based system for automatically managing POCT test results. We developed the system to provide convenience to the medical staffs. The system recognizes the patient identification or prescription number of the test by reading barcodes and provides a countdown to indicate when the results will be ready. When the countdown in finished, a picture of the test result is transferred to the electronic medical record server using the Health Level 7 protocol. Human immunodeficiency virus (HIV) kits were selected in this research because HIV is a life-threatening infectious virus, especially for the medical staff who treat undiagnosed patients. The performance of the system was verified from a survey of the users. The performance of the system was tested at the emergency room (ER) for 10 months using commercially available POCT kits for detecting HIV. The survey showed that, in total, 80% and 0% of users reported positive or negative feedback, respectively. The staff also reported that the system reduced total processing time by approximately 32 min, in addition to reducing workload. The developed automated management system was successfully tested at an ER for 10 months. The survey results show that the system is effective and that medical staff members who used the system are satisfied with using the system at the ER.

  14. Properties of materials in high pressure hydrogen at room and elevated temperatures

    NASA Technical Reports Server (NTRS)

    Harris, J. A., Jr.

    1972-01-01

    Experimental efforts in this program for this period. Mechanical property tests of wrought and cast nickel-base alloys and one wrought cobalt-base alloy were conducted in 34.5 MN/sq m (5000-psig) helium and hydrogen or hydrogen mixtures. Comparison of test results was made to determine degradation of properties due to the hydrogen environments. All testing was conducted on solid specimens exposed to external gaseous pressure. Specific mechanical properties determined and the testing methods used are summarized.

  15. Real-time acquisition and preprocessing system of transient electromagnetic data based on LabVIEW

    NASA Astrophysics Data System (ADS)

    Zhao, Huinan; Zhang, Shuang; Gu, Lingjia; Sun, Jian

    2014-09-01

    Transient electromagnetic method (TEM) is regarded as an everlasting issue for geological exploration. It is widely used in many research fields, such as mineral exploration, hydrogeology survey, engineering exploration and unexploded ordnance detection. The traditional measurement systems are often based on ARM DSP or FPGA, which have not real-time display, data preprocessing and data playback functions. In order to overcome the defects, a real-time data acquisition and preprocessing system based on LabVIEW virtual instrument development platform is proposed in the paper, moreover, a calibration model is established for TEM system based on a conductivity loop. The test results demonstrated that the system can complete real-time data acquisition and system calibration. For Transmit-Loop-Receive (TLR) response, the correlation coefficient between the measured results and the calculated results is 0.987. The measured results are basically consistent with the calculated results. Through the late inversion process for TLR, the signal of underground conductor was obtained. In the complex test environment, abnormal values usually exist in the measured data. In order to solve this problem, the judgment and revision algorithm of abnormal values is proposed in the paper. The test results proved that the proposed algorithm can effectively eliminate serious disturbance signals from the measured transient electromagnetic data.

  16. Design and evaluation of a wireless sensor network based aircraft strength testing system.

    PubMed

    Wu, Jian; Yuan, Shenfang; Zhou, Genyuan; Ji, Sai; Wang, Zilong; Wang, Yang

    2009-01-01

    The verification of aerospace structures, including full-scale fatigue and static test programs, is essential for structure strength design and evaluation. However, the current overall ground strength testing systems employ a large number of wires for communication among sensors and data acquisition facilities. The centralized data processing makes test programs lack efficiency and intelligence. Wireless sensor network (WSN) technology might be expected to address the limitations of cable-based aeronautical ground testing systems. This paper presents a wireless sensor network based aircraft strength testing (AST) system design and its evaluation on a real aircraft specimen. In this paper, a miniature, high-precision, and shock-proof wireless sensor node is designed for multi-channel strain gauge signal conditioning and monitoring. A cluster-star network topology protocol and application layer interface are designed in detail. To verify the functionality of the designed wireless sensor network for strength testing capability, a multi-point WSN based AST system is developed for static testing of a real aircraft undercarriage. Based on the designed wireless sensor nodes, the wireless sensor network is deployed to gather, process, and transmit strain gauge signals and monitor results under different static test loads. This paper shows the efficiency of the wireless sensor network based AST system, compared to a conventional AST system.

  17. Design and Evaluation of a Wireless Sensor Network Based Aircraft Strength Testing System

    PubMed Central

    Wu, Jian; Yuan, Shenfang; Zhou, Genyuan; Ji, Sai; Wang, Zilong; Wang, Yang

    2009-01-01

    The verification of aerospace structures, including full-scale fatigue and static test programs, is essential for structure strength design and evaluation. However, the current overall ground strength testing systems employ a large number of wires for communication among sensors and data acquisition facilities. The centralized data processing makes test programs lack efficiency and intelligence. Wireless sensor network (WSN) technology might be expected to address the limitations of cable-based aeronautical ground testing systems. This paper presents a wireless sensor network based aircraft strength testing (AST) system design and its evaluation on a real aircraft specimen. In this paper, a miniature, high-precision, and shock-proof wireless sensor node is designed for multi-channel strain gauge signal conditioning and monitoring. A cluster-star network topology protocol and application layer interface are designed in detail. To verify the functionality of the designed wireless sensor network for strength testing capability, a multi-point WSN based AST system is developed for static testing of a real aircraft undercarriage. Based on the designed wireless sensor nodes, the wireless sensor network is deployed to gather, process, and transmit strain gauge signals and monitor results under different static test loads. This paper shows the efficiency of the wireless sensor network based AST system, compared to a conventional AST system. PMID:22408521

  18. EGFR T790M mutation testing of non-small cell lung cancer tissue and blood samples artificially spiked with circulating cell-free tumor DNA: results of a round robin trial.

    PubMed

    Fassunke, Jana; Ihle, Michaela Angelika; Lenze, Dido; Lehmann, Annika; Hummel, Michael; Vollbrecht, Claudia; Penzel, Roland; Volckmar, Anna-Lena; Stenzinger, Albrecht; Endris, Volker; Jung, Andreas; Lehmann, Ulrich; Zeugner, Silke; Baretton, Gustavo; Kreipe, Hans; Schirmacher, Peter; Kirchner, Thomas; Dietel, Manfred; Büttner, Reinhard; Merkelbach-Bruse, Sabine

    2017-10-01

    The European Commision (EC) recently approved osimertinib for the treatment of adult patients with locally advanced or metastatic non-small-cell lung cancer (NSCLC) harboring EGFR T790M mutations. Besides tissue-based testing, blood samples containing cell-free circulating tumor DNA (ctDNA) can be used to interrogate T790M status. Herein, we describe the conditions and results of a round robin trial (RRT) for T790M mutation testing in NSCLC tissue specimens and peripheral blood samples spiked with cell line DNA mimicking tumor-derived ctDNA. The underlying objectives of this two-staged external quality assessment (EQA) approach were (a) to evaluate the accuracy of T790M mutations testing across multiple centers and (b) to investigate if a liquid biopsy-based testing for T790M mutations in spiked blood samples is feasible in routine diagnostic. Based on a successfully completed internal phase I RRT, an open RRT for EGFR T790M mutation testing in tumor tissue and blood samples was initiated. In total, 48 pathology centers participated in the EQA. Of these, 47 (97.9%) centers submitted their analyses within the pre-defined time frame and 44 (tissue), respectively, 40 (plasma) successfully passed the test. The overall success rates in the RRT phase II were 91.7% (tissue) and 83.3% (blood), respectively. Thirty-eight out of 48 participants (79.2%) successfully passed both parts of the RRT. The RRT for blood-based EGFR testing initiated in Germany is, to the best of our knowledge, the first of his kind in Europe. In summary, our results demonstrate that blood-based genotyping for EGFR resistance mutations can be successfully integrated in routine molecular diagnostics complementing the array of molecular methods already available at pathology centers in Germany.

  19. Evaluating Computer-Based Test Accommodations for English Learners

    ERIC Educational Resources Information Center

    Roohr, Katrina Crotts; Sireci, Stephen G.

    2017-01-01

    Test accommodations for English learners (ELs) are intended to reduce the language barrier and level the playing field, allowing ELs to better demonstrate their true proficiencies. Computer-based accommodations for ELs show promising results for leveling that field while also providing us with additional data to more closely investigate the…

  20. High temperature cyclic oxidation data. Part 1: Turbine alloys

    NASA Technical Reports Server (NTRS)

    Barrett, Charles A.; Garlick, Ralph G.; Lowell, Carl E.

    1989-01-01

    Specific-weight-change-versus-time data and x ray diffraction results are presented derived from high temperature cyclic tests on high temperature, high strength nickel-base gamma/gamma prime and cobalt-base turbine alloys. Each page of data summarizes a complete test on a given alloy sample.

  1. Oral vaccination of cattle with heat inactivated Mycobacterium bovis does not compromise bovine TB diagnostic tests.

    PubMed

    Jones, Gareth J; Steinbach, Sabine; Sevilla, Iker A; Garrido, Joseba M; Juste, Ramon; Vordermeier, H Martin

    2016-12-01

    In this study we investigated whether oral uptake of a heat inactivated M. bovis wildlife vaccine by domestic cattle induced systemic immune responses that compromised the use of tuberculin or defined antigens in diagnostic tests for bovine TB. Positive skin test and blood-based IFN-γ release assay (IGRA) results were observed in all calves vaccinated via the parenteral route (i.e. intramuscular). In contrast, no positive responses to tuberculin or defined antigens were observed in either the skin test or IGRA test when performed in calves vaccinated via the oral route. In conclusion, our results suggest that the heat inactivated M. bovis vaccine could be used to vaccinate wildlife in a baited form in conjunction with the following in cattle: (i) continuation of existing tuberculin skin testing or novel skin test formats based on defined antigens; and (ii) the use of IGRA tests utilizing tuberculin or defined antigens. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  2. Mod-2 wind turbine project assessment and cluster test plans

    NASA Technical Reports Server (NTRS)

    Gordon, L. H.

    1982-01-01

    An assessment of the Mod-2 Wind Turbine project is presented based on initial goals and present results. Specifically, the Mod-2 background, project flow, and a chronology of events/results leading to Mod-2 acceptance is presented. After checkout/acceptance of the three operating turbines, NASA/LeRC will continue management of a two year test program performed at the DOE Goodnoe Hills test site. This test program is expected to yield data necessary for the continued development and optimization of wind energy systems. These test activities, the implementation of, and the results to date are also presented.

  3. Oscillating-flow loss test results in rectangular heat exchanger passages

    NASA Technical Reports Server (NTRS)

    Wood, J. Gary

    1991-01-01

    Test results of oscillating flow losses in rectangular heat exchanger passages of various aspect ratios are given. This work was performed in support of the design of a free-piston Stirling engine (FPSE) for a dynamic space power conversion system. Oscillating flow loss testing was performed using an oscillating flow rig, which was based on a variable stroke and variable frequency linear drive motor. Tests were run over a range of oscillating flow parameters encompassing the flow regimes of the proposed engine design. Test results are presented in both tabular and graphical form and are compared against analytical predictions.

  4. Experimental Evaluation of Suitability of Selected Multi-Criteria Decision-Making Methods for Large-Scale Agent-Based Simulations

    PubMed Central

    2016-01-01

    Multi-criteria decision-making (MCDM) can be formally implemented by various methods. This study compares suitability of four selected MCDM methods, namely WPM, TOPSIS, VIKOR, and PROMETHEE, for future applications in agent-based computational economic (ACE) models of larger scale (i.e., over 10 000 agents in one geographical region). These four MCDM methods were selected according to their appropriateness for computational processing in ACE applications. Tests of the selected methods were conducted on four hardware configurations. For each method, 100 tests were performed, which represented one testing iteration. With four testing iterations conducted on each hardware setting and separated testing of all configurations with the–server parameter de/activated, altogether, 12800 data points were collected and consequently analyzed. An illustrational decision-making scenario was used which allows the mutual comparison of all of the selected decision making methods. Our test results suggest that although all methods are convenient and can be used in practice, the VIKOR method accomplished the tests with the best results and thus can be recommended as the most suitable for simulations of large-scale agent-based models. PMID:27806061

  5. Compilation of reinforced carbon-carbon transatlantic abort landing arc jet test results

    NASA Technical Reports Server (NTRS)

    Milhoan, James D.; Pham, Vuong T.; Yuen, Eric H.

    1993-01-01

    This document consists of the entire test database generated to support the Reinforced Carbon-Carbon Transatlantic Abort Landing Study. RCC components used for orbiter nose cap and wing leading edge thermal protection were originally designed to have a multi-mission entry capability of 2800 F. Increased orbiter range capability required a predicted increase in excess of 3300 F. Three test series were conducted. Test series #1 used ENKA-based RCC specimens coated with silicon carbide, treated with tetraethyl orthosilicate, sealed with Type A surface enhancement, and tested at 3000-3400 F with surface pressure of 60-101 psf. Series #2 used ENKA- or AVTEX-based RCC, with and without silicon carbide, Type A or double Type AA surface enhancement, all impregnated with TEOS, and at temperatures from 1440-3350 F with pressures from 100-350 psf. Series #3 tested ENKA-based RCC, with and without silicon carbide coating. No specimens were treated with TEOS or sealed with Type A. Surface temperatures ranged from 2690-3440 F and pressures ranged from 313-400 psf. These combined test results provided the database for establishing RCC material single-mission-limit temperature and developing surface recession correlations used to predict mass loss for abort conditions.

  6. Treatment Options for Ductal Carcinoma In Situ (DCIS)

    MedlinePlus

    ... using a thin needle. If cancer is found, tests are done to study the cancer cells. Decisions about the best treatment are based on the results of these tests. The tests give information about: how quickly the ...

  7. A comparative laboratory diagnosis of malaria: microscopy versus rapid diagnostic test kits.

    PubMed

    Azikiwe, C C A; Ifezulike, C C; Siminialayi, I M; Amazu, L U; Enye, J C; Nwakwunite, O E

    2012-04-01

    To compare the two methods of rapid diagnostic tests (RDTs) and microscopy in the diagnosis of malaria. RDTs and microscopy were carried out to diagnose malaria. Percentage malaria parasitaemia was calculated on thin films and all non-acute cases of plasmodiasis with less than 0.001% malaria parasitaemia were regarded as negative. Results were simply presented as percentage positive of the total number of patients under study. The results of RDTs were compared to those of microscopy while those of RDTs based on antigen were compared to those of RDTs based on antibody. Patients' follow-up was made for all cases. All the 200 patients under present study tested positive to RDTs based on malaria antibodies (serum) method (100%). 128 out of 200 tested positive to RDTs based on malaria antigen (whole blood) method (64%), while 118 out of 200 patients under present study tested positive to visual microscopy of Lieshman and diluted Giemsa (59%). All patients that tested positive to microscopy also tested positive to RDTs based on antigen. All patients on the second day of follow-up were non-febrile and had antimalaria drugs. We conclude based on the present study that the RDTs based on malaria antigen (whole blood) method is as specific as the traditional microscopy and even appears more sensitive than microscopy. The RDTs based on antibody (serum) method is unspecific thus it should not be encouraged. It is most likely that Africa being an endemic region, formation of certain levels of malaria antibody may not be uncommon. The present study also supports the opinion that a good number of febrile cases is not due to malaria. We support WHO's report on cost effectiveness of RDTs but, recommend that only the antigen based method should possibly, be adopted in Africa and other malaria endemic regions of the world.

  8. Cost-effectiveness of Population Screening for BRCA Mutations in Ashkenazi Jewish Women Compared With Family History–Based Testing

    PubMed Central

    Manchanda, Ranjit; Legood, Rosa; Burnell, Matthew; McGuire, Alistair; Raikou, Maria; Loggenberg, Kelly; Wardle, Jane; Sanderson, Saskia; Gessler, Sue; Side, Lucy; Balogun, Nyala; Desai, Rakshit; Kumar, Ajith; Dorkins, Huw; Wallis, Yvonne; Chapman, Cyril; Taylor, Rohan; Jacobs, Chris; Tomlinson, Ian; Beller, Uziel; Menon, Usha

    2015-01-01

    Background: Population-based testing for BRCA1/2 mutations detects the high proportion of carriers not identified by cancer family history (FH)–based testing. We compared the cost-effectiveness of population-based BRCA testing with the standard FH-based approach in Ashkenazi Jewish (AJ) women. Methods: A decision-analytic model was developed to compare lifetime costs and effects amongst AJ women in the UK of BRCA founder-mutation testing amongst: 1) all women in the population age 30 years or older and 2) just those with a strong FH (≥10% mutation risk). The model assumes that BRCA carriers are offered risk-reducing salpingo-oophorectomy and annual MRI/mammography screening or risk-reducing mastectomy. Model probabilities utilize the Genetic Cancer Prediction through Population Screening trial/published literature to estimate total costs, effects in terms of quality-adjusted life-years (QALYs), cancer incidence, incremental cost-effectiveness ratio (ICER), and population impact. Costs are reported at 2010 prices. Costs/outcomes were discounted at 3.5%. We used deterministic/probabilistic sensitivity analysis (PSA) to evaluate model uncertainty. Results: Compared with FH-based testing, population-screening saved 0.090 more life-years and 0.101 more QALYs resulting in 33 days’ gain in life expectancy. Population screening was found to be cost saving with a baseline-discounted ICER of -£2079/QALY. Population-based screening lowered ovarian and breast cancer incidence by 0.34% and 0.62%. Assuming 71% testing uptake, this leads to 276 fewer ovarian and 508 fewer breast cancer cases. Overall, reduction in treatment costs led to a discounted cost savings of £3.7 million. Deterministic sensitivity analysis and 94% of simulations on PSA (threshold £20000) indicated that population screening is cost-effective, compared with current NHS policy. Conclusion: Population-based screening for BRCA mutations is highly cost-effective compared with an FH-based approach in AJ women age 30 years and older. PMID:25435542

  9. A quantitative investigation of the fracture pump-in/flowback test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plahn, S.V.; Nolte, K.G.; Miska, S.

    1995-12-31

    Fracture closure pressure is an important parameter for fracture treatment design and evaluation. The pump-in/flowback (PIFB) test is frequently used to estimate its magnitude. The test is attractive because bottomhole pressures during flowback develop a distinct and repeatable signature. This is in contrast to the pump-in/shut-in test where strong indications of fracture closure are rarely seen. Various techniques exist for extracting closure pressure from the flowback pressure response. Unfortunately, these procedures give different estimates for closure pressure and their theoretical bases are not well established. We present results that place the PIFB test on a more solid foundation. A numericalmore » model is used to simulate the PIFB test and glean physical mechanisms contributing to the response. Based on our simulation results, we propose an interpretation procedure which gives better estimates for closure pressure than existing techniques.« less

  10. ROC and Loss Function Analysis in Sequential Testing

    ERIC Educational Resources Information Center

    Muijtjens, Arno M. M.; Van Luijk, Scheltus J.; Van Der Vleuten, Cees P. M.

    2006-01-01

    Sequential testing is applied to reduce costs in SP-based tests (OSCEs). Initially, all candidates take a screening test consisting of a part of the OSCE. Candidates who fail the screen sit the complete test, whereas those who pass the screen are qualified as a pass of the complete test. The procedure may result in a reduction of testing…

  11. Some attributes of a language for property-based testing.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neagoe, Vicentiu; Bishop, Matt

    Property-based testing is a testing technique that evaluates executions of a program. The method checks that specifications, called properties, hold throughout the execution of the program. TASpec is a language used to specify these properties. This paper compares some attributes of the language with the specification patterns used for model-checking languages, and then presents some descriptions of properties that can be used to detect common security flaws in programs. This report describes the results of a one year research project at the University of California, Davis, which was funded by a University Collaboration LDRD entitled ''Property-based Testing for Cyber Securitymore » Assurance''.« less

  12. Ultra-portable field transfer radiometer for vicarious calibration of earth imaging sensors

    NASA Astrophysics Data System (ADS)

    Thome, Kurtis; Wenny, Brian; Anderson, Nikolaus; McCorkel, Joel; Czapla-Myers, Jeffrey; Biggar, Stuart

    2018-06-01

    A small portable transfer radiometer has been developed as part of an effort to ensure the quality of upwelling radiance from test sites used for vicarious calibration in the solar reflective. The test sites are used to predict top-of-atmosphere reflectance relying on ground-based measurements of the atmosphere and surface. The portable transfer radiometer is designed for one-person operation for on-site field calibration of instrumentation used to determine ground-leaving radiance. The current work describes the detector- and source-based radiometric calibration of the transfer radiometer highlighting the expected accuracy and SI-traceability. The results indicate differences between the detector-based and source-based results greater than the combined uncertainties of the approaches. Results from recent field deployments of the transfer radiometer using a solar radiation based calibration agree with the source-based laboratory calibration within the combined uncertainties of the methods. The detector-based results show a significant difference to the solar-based calibration. The source-based calibration is used as the basis for a radiance-based calibration of the Landsat-8 Operational Land Imager that agrees with the OLI calibration to within the uncertainties of the methods.

  13. Super-Hydrophobic/Icephobic Coatings Based on Silica Nanoparticles Modified by Self-Assembled Monolayers.

    PubMed

    Liu, Junpeng; Janjua, Zaid A; Roe, Martin; Xu, Fang; Turnbull, Barbara; Choi, Kwing-So; Hou, Xianghui

    2016-12-02

    A super-hydrophobic surface has been obtained from nanocomposite materials based on silica nanoparticles and self-assembled monolayers of 1 H ,1 H ,2 H ,2 H -perfluorooctyltriethoxysilane (POTS) using spin coating and chemical vapor deposition methods. Scanning electron microscope images reveal the porous structure of the silica nanoparticles, which can trap small-scale air pockets. An average water contact angle of 163° and bouncing off of incoming water droplets suggest that a super-hydrophobic surface has been obtained based on the silica nanoparticles and POTS coating. The monitored water droplet icing test results show that icing is significantly delayed by silica-based nano-coatings compared with bare substrates and commercial icephobic products. Ice adhesion test results show that the ice adhesion strength is reduced remarkably by silica-based nano-coatings. The bouncing phenomenon of water droplets, the icing delay performance and the lower ice adhesion strength suggest that the super-hydrophobic coatings based on a combination of silica and POTS also show icephobicity. An erosion test rig based on pressurized pneumatic water impinging impact was used to evaluate the durability of the super-hydrophobic/icephobic coatings. The results show that durable coatings have been obtained, although improvement will be needed in future work aiming for applications in aerospace.

  14. Evidence-based guidelines for anti-allergic drug withdrawal times before allergen-specific intradermal and IgE serological tests in dogs.

    PubMed

    Olivry, Thierry; Saridomichelakis, Manolis

    2013-04-01

    Anti-allergic drugs (e.g. antihistamines, glucocorticoids and ciclosporin) are often administered to dogs with atopic dermatitis to relieve pruritus and skin lesions. Allergen-specific intradermal tests (IDT) and allergen-specific IgE serological (ASIS) tests are used to characterize the allergens to which dogs are hypersensitive. Anti-allergic drugs have the potential to influence the results or interpretation of these tests. To provide evidence-based recommendations for anti-allergic drug withdrawal times before IDT and ASIS tests. Three citation databases and abstracts from international meetings were searched for relevant studies. Studies were grouped based on similar interventions and types of tests. Withdrawal times for each type of drug and test were then extrapolated from the study results. Before the assessment of immediate reactions to IDT, proposed optimal withdrawal times for antihistamines, oral glucocorticoids, topical/otic glucocorticoids and ciclosporin are 7, 14, 14 and 0 days, respectively. Studies have provided no evidence for drug withdrawal prior to ASIS tests for oral ciclosporin or prednisone/prednisolone. Owing to a lack of studies, recommendations for withdrawal times before ASIS tests cannot be made for topical glucocorticoids and antihistamines. These proposed withdrawal times are based on the existing evidence at the end of 2011. Care must be taken before extrapolating the suggested withdrawal times to other species, higher dosages, different formulations and/or durations of administration of tested drugs, as well as to other medications from the same category. © 2013 The Authors. Veterinary Dermatology © 2013 ESVD and ACVD.

  15. Loran Automatic Vehicle Monitoring System, Phase I : Volume 1. Test Results.

    DOT National Transportation Integrated Search

    1977-08-01

    Presents results of the evaluation phase of a two phase program to develop an Automatic Vehicle Monitoring (AVM) system for the Southern California Rapid Transit District in Los Angeles, California. Tests were previously conducted on a Loran based lo...

  16. LOW EMISSION AND HIGH EFFICIENCY RESIDENTIAL PELLET-FIRED HEATERS

    EPA Science Inventory

    The paper gives results of air emissions testing and efficiency testing on new commercially available under-feed and top-feed residential heaters burning hardwood- and softwood-based pellets. The results were compared with data from earlier models. Reductions in air emissions w...

  17. Privacy-preserving genomic testing in the clinic: a model using HIV treatment.

    PubMed

    McLaren, Paul J; Raisaro, Jean Louis; Aouri, Manel; Rotger, Margalida; Ayday, Erman; Bartha, István; Delgado, Maria B; Vallet, Yannick; Günthard, Huldrych F; Cavassini, Matthias; Furrer, Hansjakob; Doco-Lecompte, Thanh; Marzolini, Catia; Schmid, Patrick; Di Benedetto, Caroline; Decosterd, Laurent A; Fellay, Jacques; Hubaux, Jean-Pierre; Telenti, Amalio

    2016-08-01

    The implementation of genomic-based medicine is hindered by unresolved questions regarding data privacy and delivery of interpreted results to health-care practitioners. We used DNA-based prediction of HIV-related outcomes as a model to explore critical issues in clinical genomics. We genotyped 4,149 markers in HIV-positive individuals. Variants allowed for prediction of 17 traits relevant to HIV medical care, inference of patient ancestry, and imputation of human leukocyte antigen (HLA) types. Genetic data were processed under a privacy-preserving framework using homomorphic encryption, and clinical reports describing potentially actionable results were delivered to health-care providers. A total of 230 patients were included in the study. We demonstrated the feasibility of encrypting a large number of genetic markers, inferring patient ancestry, computing monogenic and polygenic trait risks, and reporting results under privacy-preserving conditions. The average execution time of a multimarker test on encrypted data was 865 ms on a standard computer. The proportion of tests returning potentially actionable genetic results ranged from 0 to 54%. The model of implementation presented herein informs on strategies to deliver genomic test results for clinical care. Data encryption to ensure privacy helps to build patient trust, a key requirement on the road to genomic-based medicine.Genet Med 18 8, 814-822.

  18. MHD generator electrode development. Summary report, July 1, 1981-September 30, 1982

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rossing, B.R.; Buckman, R.W. Jr.; Pouchot, W.D.

    Emphasis on this program was the development of and understanding wastage mechanism(s) of metallic electrodes which may be suitable alternatives to platinum anode material for use in long-term open cycle, coal-fired MHD generator operations. The laboratory tests simulate both modes of material wastage observed in MHD electrode operation; i.e., arc erosion (melting/vaporization) and electrochemical corrosion. Based on experimental results from the electrochemical tests at 1473/sup 0/K, the rank order listing of the materials tested for anode applications were platinum, E-Brite 26-1 modified with a five percent addition of platinum, chromium, IN 601, E-Brite 26-1, and 330 stainless steel ranked inmore » decreasing order. The rank order listing based on the arc erosion test was platinum, chromium, E-Brite 26-1, 330 stainless steel, and IN 601. The relative arc erosion resistance of materials based on the AVCO Mark VII generator test results gave a rank order of platinum, 330 stainless steel, IN 601, and E-Brite 26-1. Engineering tests under simulated open-cycle coal-fired MHD operating conditions were performed in the 500 kW Westinghouse Electrode System Test Facility (WESTF). Tests were conducted on candidate metallic anode materials (cold wall) and ceramic anode (hot wall) materials. A ten-hour duration cold wall slagging test was conducted on platinum, E-Brite 26-1, 330 stainless steel and IN 601 and the results were similar to those obtained for those materials in the AVCO Mark VII generator tests. Non-slagging, super hot (>1700/sup 0/C) wall hafnia-rare earth oxide electrodes were tested in a sulfurous, western coal-fired MHD environment. All four ceramic electrode pairs were destroyed. 20 references.« less

  19. Active implantable medical device EMI assessment for wireless power transfer operating in LF and HF bands.

    PubMed

    Hikage, Takashi; Nojima, Toshio; Fujimoto, Hiroshi

    2016-06-21

    The electromagnetic interference (EMI) imposed on active implantable medical devices by wireless power transfer systems (WPTSs) is discussed based upon results of in vitro experiments. The purpose of this study is to present comprehensive EMI test results gathered from implantable-cardiac pacemakers and implantable cardioverter defibrillators exposed to the electromagnetic field generated by several WPTSs operating in low-frequency (70 kHz-460 kHz) and high-frequency (6.78 MHz) bands. The constructed in vitro experimental test system based upon an Irnich's flat torso phantom was applied. EMI test experiments are conducted on 14 types of WPTSs including Qi-compliant system and EV-charging WPT system mounted on current production EVs. In addition, a numerical simulation model for active implantable medical device (AIMD) EMI estimation based on the experimental test system is newly proposed. The experimental results demonstrate the risk of WPTSs emitting intermittent signal to affect the correct behavior of AIMDs when operating at very short distances. The proposed numerical simulation model is applicable to obtain basically the EMI characteristics of various types of WPTSs.

  20. Active implantable medical device EMI assessment for wireless power transfer operating in LF and HF bands

    NASA Astrophysics Data System (ADS)

    Hikage, Takashi; Nojima, Toshio; Fujimoto, Hiroshi

    2016-06-01

    The electromagnetic interference (EMI) imposed on active implantable medical devices by wireless power transfer systems (WPTSs) is discussed based upon results of in vitro experiments. The purpose of this study is to present comprehensive EMI test results gathered from implantable-cardiac pacemakers and implantable cardioverter defibrillators exposed to the electromagnetic field generated by several WPTSs operating in low-frequency (70 kHz-460 kHz) and high-frequency (6.78 MHz) bands. The constructed in vitro experimental test system based upon an Irnich’s flat torso phantom was applied. EMI test experiments are conducted on 14 types of WPTSs including Qi-compliant system and EV-charging WPT system mounted on current production EVs. In addition, a numerical simulation model for active implantable medical device (AIMD) EMI estimation based on the experimental test system is newly proposed. The experimental results demonstrate the risk of WPTSs emitting intermittent signal to affect the correct behavior of AIMDs when operating at very short distances. The proposed numerical simulation model is applicable to obtain basically the EMI characteristics of various types of WPTSs.

  1. Flow Channel Influence of a Collision-Based Piezoelectric Jetting Dispenser on Jet Performance

    PubMed Central

    Deng, Guiling; Li, Junhui; Duan, Ji’an

    2018-01-01

    To improve the jet performance of a bi-piezoelectric jet dispenser, mathematical and simulation models were established according to the operating principle. In order to improve the accuracy and reliability of the simulation calculation, a viscosity model of the fluid was fitted to a fifth-order function with shear rate based on rheological test data, and the needle displacement model was fitted to a nine-order function with time based on real-time displacement test data. The results show that jet performance is related to the diameter of the nozzle outlet and the cone angle of the nozzle, and the impacts of the flow channel structure were confirmed. The approach of numerical simulation is confirmed by the testing results of droplet volume. It will provide a reliable simulation platform for mechanical collision-based jet dispensing and a theoretical basis for micro jet valve design and improvement. PMID:29677140

  2. Tests of 38 Ball-Bearing Greases

    NASA Technical Reports Server (NTRS)

    Mcmurtrey, E. L.

    1982-01-01

    Report presents interim results in program of long-term tests of ball-bearing greases in vacuum, oxidizing, and otherwise hostile environment. Program is motivated by need for mechanisms that will operate for long periods in spacecraft or space stations. Class of lubricants based on perfluoroalkylpolyether (PFPE) with fluorotelomer thickeners has given best results in vacuum tests completed thus far. Test methods and performances of various lubricants could be of interest in automotive and industrial communities.

  3. Cognitive Testing in People at Increased Risk of Dementia Using a Smartphone App: The iVitality Proof-of-Principle Study

    PubMed Central

    Wijsman, Liselotte Willemijn; Cachucho, Ricardo; Hoevenaar-Blom, Marieke Peternella; Mooijaart, Simon Pieter; Richard, Edo

    2017-01-01

    Background Smartphone-assisted technologies potentially provide the opportunity for large-scale, long-term, repeated monitoring of cognitive functioning at home. Objective The aim of this proof-of-principle study was to evaluate the feasibility and validity of performing cognitive tests in people at increased risk of dementia using smartphone-based technology during a 6 months follow-up period. Methods We used the smartphone-based app iVitality to evaluate five cognitive tests based on conventional neuropsychological tests (Memory-Word, Trail Making, Stroop, Reaction Time, and Letter-N-Back) in healthy adults. Feasibility was tested by studying adherence of all participants to perform smartphone-based cognitive tests. Validity was studied by assessing the correlation between conventional neuropsychological tests and smartphone-based cognitive tests and by studying the effect of repeated testing. Results We included 151 participants (mean age in years=57.3, standard deviation=5.3). Mean adherence to assigned smartphone tests during 6 months was 60% (SD 24.7). There was moderate correlation between the firstly made smartphone-based test and the conventional test for the Stroop test and the Trail Making test with Spearman ρ=.3-.5 (P<.001). Correlation increased for both tests when comparing the conventional test with the mean score of all attempts a participant had made, with the highest correlation for Stroop panel 3 (ρ=.62, P<.001). Performance on the Stroop and the Trail Making tests improved over time suggesting a learning effect, but the scores on the Letter-N-back, the Memory-Word, and the Reaction Time tests remained stable. Conclusions Repeated smartphone-assisted cognitive testing is feasible with reasonable adherence and moderate relative validity for the Stroop and the Trail Making tests compared with conventional neuropsychological tests. Smartphone-based cognitive testing seems promising for large-scale data-collection in population studies. PMID:28546139

  4. School-Based HIV/STD Testing Behaviors and Motivations Among Black and Hispanic Teen MSM: Results From a Formative Evaluation

    PubMed Central

    Morris, Elana; Topete, Pablo; Rasberry, Catherine N.; Lesesne, Catherine A.; Kroupa, Elizabeth; Carver, Lisa

    2018-01-01

    BACKGROUND This evaluation explores experiences with, and motivations for, human immunodeficiency virus (HIV) and sexually transmitted disease (STD) testing among black and Hispanic school-aged young men who have sex with men (YMSM). METHODS Participants were recruited at community-based organizations that serve YMSM in New York City, Philadelphia, and San Francisco. Eligible participants were 13- to 19-year-old black or Hispanic males who reported attraction to or sexual behavior with other males and/or identified as gay or bisexual, and attended at least 90 days of school in the previous 18 months. Participants (N = 415) completed web-based questionnaires and/or in-depth interviews (N = 32). RESULTS In the past year, 72.0% of questionnaire participants had been tested for HIV, 13.5% of them at school or school clinic. Participants reported that they would be more likely to get an HIV test if they could be tested close to or at school (34.4%), and 64.4% would use HIV testing if offered in schools. Most interview participants reported willingness to use school-based services if they were offered nonjudgmentally, privately, and confidentially by providers with experience serving YMSM. CONCLUSION Schools can provide opportunities to make HIV and STD testing accessible to school-aged YMSM, but the services must be provided in ways that are comfortable to them. PMID:27866390

  5. The Effect of Font Selection on Student Test Anxiety

    ERIC Educational Resources Information Center

    Murphy, Peter V.

    2014-01-01

    The emergence of standards-based curriculums has resulted in an increased frequency of student testing, including high-stakes testing. Of students who take tests, up to 65% may experience test anxiety, which can have negative effects on student outcomes. For this reason, the purpose of this single-group, repeated measures design, quantitative…

  6. Investigation on aerodynamic characteristics of baseline-II E-2 blended wing-body aircraft with canard via computational simulation

    NASA Astrophysics Data System (ADS)

    Nasir, Rizal E. M.; Ali, Zurriati; Kuntjoro, Wahyu; Wisnoe, Wirachman

    2012-06-01

    Previous wind tunnel test has proven the improved aerodynamic charasteristics of Baseline-II E-2 Blended Wing-Body (BWB) aircraft studied in Universiti Teknologi Mara. The E-2 is a version of Baseline-II BWB with modified outer wing and larger canard, solely-designed to gain favourable longitudinal static stability during flight. This paper highlights some results from current investigation on the said aircraft via computational fluid dynamics simulation as a mean to validate the wind tunnel test results. The simulation is conducted based on standard one-equation turbulence, Spalart-Allmaras model with polyhedral mesh. The ambience of the flight simulation is made based on similar ambience of wind tunnel test. The simulation shows lift, drag and moment results to be near the values found in wind tunnel test but only within angles of attack where the lift change is linear. Beyond the linear region, clear differences between computational simulation and wind tunnel test results are observed. It is recommended that different type of mathematical model be used to simulate flight conditions beyond linear lift region.

  7. Development of dynamic Bayesian models for web application test management

    NASA Astrophysics Data System (ADS)

    Azarnova, T. V.; Polukhin, P. V.; Bondarenko, Yu V.; Kashirina, I. L.

    2018-03-01

    The mathematical apparatus of dynamic Bayesian networks is an effective and technically proven tool that can be used to model complex stochastic dynamic processes. According to the results of the research, mathematical models and methods of dynamic Bayesian networks provide a high coverage of stochastic tasks associated with error testing in multiuser software products operated in a dynamically changing environment. Formalized representation of the discrete test process as a dynamic Bayesian model allows us to organize the logical connection between individual test assets for multiple time slices. This approach gives an opportunity to present testing as a discrete process with set structural components responsible for the generation of test assets. Dynamic Bayesian network-based models allow us to combine in one management area individual units and testing components with different functionalities and a direct influence on each other in the process of comprehensive testing of various groups of computer bugs. The application of the proposed models provides an opportunity to use a consistent approach to formalize test principles and procedures, methods used to treat situational error signs, and methods used to produce analytical conclusions based on test results.

  8. Comparison of Estrogen Receptor Assay Results from Pathology Reports with Results from Central Laboratory Testing: Implications for Population-Based Studies of Breast Cancer

    PubMed Central

    Collins, LC; Marotti, J; Baer, HJ; Deitz, AC; Colditz, GA; Tamimi, RM

    2014-01-01

    Population-based studies of women with breast cancer commonly utilize information culled from pathology reports rather than central pathology review. The reliability of this information, particularly with regard to tumor biomarker results, is of concern. To address this, we evaluated the concordance between estrogen receptor (ER) results as determined from the original pathology reports and ER results obtained on the same specimens following testing in a single laboratory. Tissue microarrays (TMAs) were constructed from paraffin blocks of 3,167 breast cancers that developed in women enrolled in the Nurses’ Health Study. ER immunostains were performed on all TMA sections in single run. Results of ER immunostains performed on the TMA sections were compared with ER assay results abstracted from pathology reports. Among 1,851 cases of invasive breast cancer in which both ER results from pathology reports and central ER test results were available, the reported ER status and the ER status as determined from immunostains on TMAs were in agreement in 1,651 cases (87.3 %; kappa value 0.64, p<0.0001). When the comparison was restricted to ER assays originally performed by immunohistochemistry, the agreement rate increased to 92.3% (kappa value 0.78, p<0.0001). These results provide a framework for the accuracy of ER results abstracted from clinical records. Further, they suggest that utilizing ER assay results from pathology reports is a reasonable, albeit imperfect, alternative to central laboratory ER testing for large, population-based studies of patients with breast cancer. PMID:18230800

  9. Evaluation of selected static methods used to estimate element mobility, acid-generating and acid-neutralizing potentials associated with geologically diverse mining wastes

    USGS Publications Warehouse

    Hageman, Philip L.; Seal, Robert R.; Diehl, Sharon F.; Piatak, Nadine M.; Lowers, Heather

    2015-01-01

    A comparison study of selected static leaching and acid–base accounting (ABA) methods using a mineralogically diverse set of 12 modern-style, metal mine waste samples was undertaken to understand the relative performance of the various tests. To complement this study, in-depth mineralogical studies were conducted in order to elucidate the relationships between sample mineralogy, weathering features, and leachate and ABA characteristics. In part one of the study, splits of the samples were leached using six commonly used leaching tests including paste pH, the U.S. Geological Survey (USGS) Field Leach Test (FLT) (both 5-min and 18-h agitation), the U.S. Environmental Protection Agency (USEPA) Method 1312 SPLP (both leachate pH 4.2 and leachate pH 5.0), and the USEPA Method 1311 TCLP (leachate pH 4.9). Leachate geochemical trends were compared in order to assess differences, if any, produced by the various leaching procedures. Results showed that the FLT (5-min agitation) was just as effective as the 18-h leaching tests in revealing the leachate geochemical characteristics of the samples. Leaching results also showed that the TCLP leaching test produces inconsistent results when compared to results produced from the other leaching tests. In part two of the study, the ABA was determined on splits of the samples using both well-established traditional static testing methods and a relatively quick, simplified net acid–base accounting (NABA) procedure. Results showed that the traditional methods, while time consuming, provide the most in-depth data on both the acid generating, and acid neutralizing tendencies of the samples. However, the simplified NABA method provided a relatively fast, effective estimation of the net acid–base account of the samples. Overall, this study showed that while most of the well-established methods are useful and effective, the use of a simplified leaching test and the NABA acid–base accounting method provide investigators fast, quantitative tools that can be used to provide rapid, reliable information about the leachability of metals and other constituents of concern, and the acid-generating potential of metal mining waste.

  10. An Investigation of the Learning Strategies as Bias Factors in Second Language Cloze Tests

    ERIC Educational Resources Information Center

    Ajideh, Parviz; Yaghoubi-Notash, Massoud; Khalili, Abdolreza

    2017-01-01

    The present study investigated the contribution of the EFL students' learning strategies to the explanation of the variance in their results on language tests. More specifically, it examined the role of these strategies as bias factors in the results of English cloze tests. Based on this aim, first, 158 intermediate EFL learners were selected from…

  11. Microcomputer Assisted Interpretative Reporting of Sequential Creatine Kinase (CK) and Lactate Dehydrogenase (LDH) Isoenzyme Determination

    PubMed Central

    Talamo, Thomas S.; Losos, Frank J.; Mercer, Donald W.

    1984-01-01

    We have developed a microcomputer based system for interpretative reporting of creatine kinase (CK) and lactate dehydrogenase (LDH) isoenzyme studies. Patient demographic data and test results (total CK, CK-MB, LD-1, and LD-2) are entered manually through the keyboard. The test results are compared with normal range values and an interpretative report is generated. This report consists of all pertinent demographic information with a graphic display of up to 12 previous CK and LDH isoenzyme determinations. Diagnostic interpretative statements are printed beneath the graphic display following analysis of previously entered test results. The combination of graphic data display and interpretations based on analysis of up to 12 previous specimens provides useful and accurate information to the cardiologist.

  12. Improve Outcomes Study subjects Chemistry Teaching and Learning Strategies through independent study with the help of computer-based media

    NASA Astrophysics Data System (ADS)

    Sugiharti, Gulmah

    2018-03-01

    This study aims to see the improvement of student learning outcomes by independent learning using computer-based learning media in the course of STBM (Teaching and Learning Strategy) Chemistry. Population in this research all student of class of 2014 which take subject STBM Chemistry as many as 4 class. While the sample is taken by purposive as many as 2 classes, each 32 students, as control class and expriment class. The instrument used is the test of learning outcomes in the form of multiple choice with the number of questions as many as 20 questions that have been declared valid, and reliable. Data analysis techniques used one-sided t test and improved learning outcomes using a normalized gain test. Based on the learning result data, the average of normalized gain values for the experimental class is 0,530 and for the control class is 0,224. The result of the experimental student learning result is 53% and the control class is 22,4%. Hypothesis testing results obtained t count> ttable is 9.02> 1.6723 at the level of significance α = 0.05 and db = 58. This means that the acceptance of Ha is the use of computer-based learning media (CAI Computer) can improve student learning outcomes in the course Learning Teaching Strategy (STBM) Chemistry academic year 2017/2018.

  13. Screening methods for assessment of biodegradability of chemicals in seawater--results from a ring test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nyholm, N.; Kristensen, P.

    1992-04-01

    An international ring test involving 14 laboratories was organized on behalf of the Commission of the European Economic Communities (EEC) with the purpose of evaluating two proposed screening methods for assessment of biodegradability in seawater: (a) a shake flask die-away test based primarily on analysis of dissolved organic carbon and (b) a closed bottle test based on determination of dissolved oxygen. Both tests are performed with nutrient-enriched natural seawater as the test medium and with no inoculum added other than the natural seawater microflora. The test methods are seawater versions of the modified OECD screening test and the closed bottlemore » test, respectively, adopted by the Organization for Economic Cooperation and Development (OECD) and by the EEC as tests for ready biodegradability.' The following five chemicals were examined: sodium benzoate, aniline, diethylene glycol, pentaerythritol, and 4-nitrophenol. Sodium benzoate and aniline, which are known to be generally readily biodegradable consistently degraded in practically all tests, thus demonstrating the technical feasibility of the methods. Like in previous ring tests with freshwater screening methods variable results were obtained with the other three compounds, which is believed primarily to be due to site-specific differences between the microflora of the different seawater samples used and to some extent also to differences in the applied concentrations of test material. A positive result with the screening methods indicates that the test substance will most likely degrade relatively rapidly in seawater from the site of collection, while a negative test result does not preclude biodegradability under environmental conditions where the concentrations of chemicals are much lower than the concentrations applied for analytical reasons in screening tests.« less

  14. Developing software to "track and catch" missed follow-up of abnormal test results in a complex sociotechnical environment.

    PubMed

    Smith, M; Murphy, D; Laxmisan, A; Sittig, D; Reis, B; Esquivel, A; Singh, H

    2013-01-01

    Abnormal test results do not always receive timely follow-up, even when providers are notified through electronic health record (EHR)-based alerts. High workload, alert fatigue, and other demands on attention disrupt a provider's prospective memory for tasks required to initiate follow-up. Thus, EHR-based tracking and reminding functionalities are needed to improve follow-up. The purpose of this study was to develop a decision-support software prototype enabling individual and system-wide tracking of abnormal test result alerts lacking follow-up, and to conduct formative evaluations, including usability testing. We developed a working prototype software system, the Alert Watch And Response Engine (AWARE), to detect abnormal test result alerts lacking documented follow-up, and to present context-specific reminders to providers. Development and testing took place within the VA's EHR and focused on four cancer-related abnormal test results. Design concepts emphasized mitigating the effects of high workload and alert fatigue while being minimally intrusive. We conducted a multifaceted formative evaluation of the software, addressing fit within the larger socio-technical system. Evaluations included usability testing with the prototype and interview questions about organizational and workflow factors. Participants included 23 physicians, 9 clinical information technology specialists, and 8 quality/safety managers. Evaluation results indicated that our software prototype fit within the technical environment and clinical workflow, and physicians were able to use it successfully. Quality/safety managers reported that the tool would be useful in future quality assurance activities to detect patients who lack documented follow-up. Additionally, we successfully installed the software on the local facility's "test" EHR system, thus demonstrating technical compatibility. To address the factors involved in missed test results, we developed a software prototype to account for technical, usability, organizational, and workflow needs. Our evaluation has shown the feasibility of the prototype as a means of facilitating better follow-up for cancer-related abnormal test results.

  15. How well do general practitioners manage laboratory test results for patients with diabetes mellitus and cardiovascular disease?: A systematic review.

    PubMed

    McCaughey, Euan J; Li, Julie; Badrick, Tony C; Westbrook, Johanna I; Georgiou, Andrew

    2017-10-01

    To evaluate how well general practitioners (GPs) manage and respond to laboratory results for patients with diabetes mellitus (DM) and cardiovascular disease (CVD). MEDLINE, CINAHL, Embase, EBM reviews, ProQuest and Scopus. Peer-reviewed journal articles published between 2000 and 2015 that assessed GPs' management of laboratory results for patients with DM or CVD. Study design and demographics, laboratory tests and key findings relating to GP management of laboratory results were extracted from studies. Thirteen articles were included, comprising seven studies which utilized surveys, four observational studies, one cohort study and one randomized controlled trial. Findings indicate that GPs often overestimate the risk of complications associated with DM and CVD based on laboratory results and have unrealistically high expectations regarding the precision of laboratory tests. Considerable variation existed in the use of repeat testing for diagnostic confirmation and in GPs' identification of the difference between two consecutive results required to indicate a change in patient condition. GPs also often failed to initiate appropriate treatment for patients with DM and CVD based on laboratory results. Feedback to GPs about their test ordering patterns and educational messages on laboratory results improved clinical outcomes. Evidence about how well GPs manage results and its impact on patient outcomes remains weak and inconclusive. This review identified a number of areas where interventions could support GPs to improve the interpretation and management of laboratory test results, including feedback to GPs and educational messages on test result reports. © The Author 2017. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  16. Testing of a De Nora polymer electrolyte fuel cell stack of 1 kW for naval applications

    NASA Astrophysics Data System (ADS)

    Schmal, D.; Kluiters, C. E.; Barendregt, I. P.

    In a previous study calculations were carried out for a navy frigate with respect to the energy consumption of a propulsion/electricity generation system based on fuel cells. The fuel consumption for the 'all-fuel cell' ship was compared with the consumption of the current propulsion/electricity generation system based on gas turbines and diesel engines; it showed potential energy savings of a fuel cell based system amounting from 25 to 30%. On the basis of these results and taking into account various military aspects it was decided to start tests with a polymer electrolyte fuel cell (PEFC) stack. For this purpose a De Nora 1 kW PEFC was chosen. Results of the first tests after installation are satisfying.

  17. USB environment measurements based on full-scale static engine ground tests. [Upper Surface Blowing for YC-14

    NASA Technical Reports Server (NTRS)

    Sussman, M. B.; Harkonen, D. L.; Reed, J. B.

    1976-01-01

    Flow turning parameters, static pressures, surface temperatures, surface fluctuating pressures and acceleration levels were measured in the environment of a full-scale upper surface blowing (USB) propulsive-lift test configuration. The test components included a flightworthy CF6-50D engine, nacelle and USB flap assembly utilized in conjunction with ground verification testing of the USAF YC-14 Advanced Medium STOL Transport propulsion system. Results, based on a preliminary analysis of the data, generally show reasonable agreement with predicted levels based on model data. However, additional detailed analysis is required to confirm the preliminary evaluation, to help delineate certain discrepancies with model data and to establish a basis for future flight test comparisons.

  18. Threshold Assessment of Gear Diagnostic Tools on Flight and Test Rig Data

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Mosher, Marianne; Huff, Edward M.

    2003-01-01

    A method for defining thresholds for vibration-based algorithms that provides the minimum number of false alarms while maintaining sensitivity to gear damage was developed. This analysis focused on two vibration based gear damage detection algorithms, FM4 and MSA. This method was developed using vibration data collected during surface fatigue tests performed in a spur gearbox rig. The thresholds were defined based on damage progression during tests with damage. The thresholds false alarm rates were then evaluated on spur gear tests without damage. Next, the same thresholds were applied to flight data from an OH-58 helicopter transmission. Results showed that thresholds defined in test rigs can be used to define thresholds in flight to correctly classify the transmission operation as normal.

  19. Developing Software to “Track and Catch” Missed Follow-up of Abnormal Test Results in a Complex Sociotechnical Environment

    PubMed Central

    Smith, M.; Murphy, D.; Laxmisan, A.; Sittig, D.; Reis, B.; Esquivel, A.; Singh, H.

    2013-01-01

    Summary Background Abnormal test results do not always receive timely follow-up, even when providers are notified through electronic health record (EHR)-based alerts. High workload, alert fatigue, and other demands on attention disrupt a provider’s prospective memory for tasks required to initiate follow-up. Thus, EHR-based tracking and reminding functionalities are needed to improve follow-up. Objectives The purpose of this study was to develop a decision-support software prototype enabling individual and system-wide tracking of abnormal test result alerts lacking follow-up, and to conduct formative evaluations, including usability testing. Methods We developed a working prototype software system, the Alert Watch And Response Engine (AWARE), to detect abnormal test result alerts lacking documented follow-up, and to present context-specific reminders to providers. Development and testing took place within the VA’s EHR and focused on four cancer-related abnormal test results. Design concepts emphasized mitigating the effects of high workload and alert fatigue while being minimally intrusive. We conducted a multifaceted formative evaluation of the software, addressing fit within the larger socio-technical system. Evaluations included usability testing with the prototype and interview questions about organizational and workflow factors. Participants included 23 physicians, 9 clinical information technology specialists, and 8 quality/safety managers. Results Evaluation results indicated that our software prototype fit within the technical environment and clinical workflow, and physicians were able to use it successfully. Quality/safety managers reported that the tool would be useful in future quality assurance activities to detect patients who lack documented follow-up. Additionally, we successfully installed the software on the local facility’s “test” EHR system, thus demonstrating technical compatibility. Conclusion To address the factors involved in missed test results, we developed a software prototype to account for technical, usability, organizational, and workflow needs. Our evaluation has shown the feasibility of the prototype as a means of facilitating better follow-up for cancer-related abnormal test results. PMID:24155789

  20. Development of bio based plastic materials for packaging from soybeans waste

    NASA Astrophysics Data System (ADS)

    Muhammad, A.; Rashidi, A. R.; Roslan, A.; Idris, S. A.

    2017-09-01

    Demands of plastic material which increase with the increasing of human population encourage researchers to find alternative solution to replace petro based plastic. Thus, in the present study, a novel "green bioplastic" packaging was developed using soybean waste which is a major waste in soy sauce food industry. The evaluation of the effect of ratio of starch, soy waste and plasticizer in this bioplastic production was studied and their characteristics were compared with available bioplastics. Characteristics study was done in terms of burning test, water absorption capacity, thermal and tensile strength measurement and the result obtained were analyzed. The glass transition temperature (Tg) for soy waste bioplastic is 117˚C. The water absorption test shows that an increase in mass up to 114.17% which show large amount of water uptake capacity of this bioplastics. And about 38% of percentage loss was observed when compared with other novel bioplastics. The results clearly show that the amount of glycerol as a plasticizer had an inversely proportional relationship with the Glass Transition Temperature (Tg). The average maximum force value for tensile strength test is 6.71 N. The burning test show that the soy wastes bioplastic release a very faint smell of soy and glue-like substance. The flame ignited a Yellowish-Orange colour and released some sparks. Based on the overall results, soy-based have been proven to become an excellent bio-based packaging materials.

  1. A flight investigation of the spinning of the NY-1 airplane with varied mass distribution and other modifications, and an analysis based on wind-tunnel tests

    NASA Technical Reports Server (NTRS)

    Scudder, Nathan F

    1934-01-01

    This report presents the results of an investigation of the spinning characteristics of NY-1 naval training biplane. The results of flight tests and an analysis based on wind-tunnel test data are given and compared. The primary purpose of the investigation was the determination in flight of the effect of changes in mass distribution along the longitudinal axis, without change of mass quantity or centroid. Other effects were also investigated, such as those due to wing loading, center-of-gravity position, dihedral of wings, control setting, and the removal of a large portion of the fabric from the fin and rudder. The wind tunnel test results used in the numerical analysis were obtained in the 7 by 10 foot wind tunnel through an angle-of-attack.

  2. Uptake and linkage into care over one year of providing HIV testing and counselling through community and health facility testing modalities in urban informal settlement of Kibera, Nairobi Kenya.

    PubMed

    Muhula, Samuel; Memiah, Peter; Mbau, Lilian; Oruko, Happiness; Baker, Bebora; Ikiara, Geoffrey; Mungai, Margaret; Ndirangu, Meshack; Achwoka, Dunstan; Ilako, Festus

    2016-05-04

    We examine the uptake of HIV Testing and Counselling (HTC) and linkage into care over one year of providing HTC through community and health facility testing modalities among people living in Kibera informal urban settlement in Nairobi Kenya. We analyzed program data on health facility-based HIV testing and counselling and community- based testing and counselling approaches for the period starting October 2013 to September 2014. Univariate and bivariate analysis methods were used to compare the two approaches with regard to uptake of HTC and subsequent linkage to care. The exact Confidence Intervals (CI) to the proportions were approximated using simple normal approximation to binomial distribution method. Majority of the 18,591 clients were tested through health facility-based testing approaches 72.5 % (n = 13485) vs those tested through community-based testing comprised 27.5 % (n = 5106). More clients tested at health facilities were reached through Provider Initiated Testing and Counselling PITC 81.7 % (n = 11015) while 18.3 % were reached through Voluntary Counselling and Testing (VCT)/Client Initiated Testing and Counselling (CITC) services. All clients who tested positive during health facility-based testing were successfully linked to care either at the project sites or sites of client choice while not all who tested positive during community based testing were linked to care. The HIV prevalence among all those who were tested for HIV in the program was 5.2 % (n = 52, 95 % CI: 3.9 %-6.8 %). Key study limitation included use of aggregate data to report uptake of HTC through the two testing approaches and not being able to estimate the population in the catchment area likely to test for HIV. Health facility-based HTC approach achieved more clients tested for HIV, and this method also resulted in identifying greater numbers of people who were HIV positive in Kibera slum within one year period of testing for HIV compared to community-based HTC approach. Linking HIV positive clients to care proved much easier during health facility- based HTC compared to community- based HTC.

  3. Space Launch System Base Heating Test: Environments and Base Flow Physics

    NASA Technical Reports Server (NTRS)

    Mehta, Manish; Knox, Kyle S.; Seaford, C. Mark; Dufrene, Aaron T.

    2016-01-01

    The NASA Space Launch System (SLS) vehicle is composed of four RS-25 liquid oxygen- hydrogen rocket engines in the core-stage and two 5-segment solid rocket boosters and as a result six hot supersonic plumes interact within the aft section of the vehicle during ight. Due to the complex nature of rocket plume-induced ows within the launch vehicle base during ascent and a new vehicle con guration, sub-scale wind tunnel testing is required to reduce SLS base convective environment uncertainty and design risk levels. This hot- re test program was conducted at the CUBRC Large Energy National Shock (LENS) II short-duration test facility to simulate ight from altitudes of 50 kft to 210 kft. The test program is a challenging and innovative e ort that has not been attempted in 40+ years for a NASA vehicle. This presentation discusses the various trends of base convective heat ux and pressure as a function of altitude at various locations within the core-stage and booster base regions of the two-percent SLS wind tunnel model. In-depth understanding of the base ow physics is presented using the test data, infrared high-speed imaging and theory. The normalized test design environments are compared to various NASA semi- empirical numerical models to determine exceedance and conservatism of the ight scaled test-derived base design environments. Brief discussion of thermal impact to the launch vehicle base components is also presented.

  4. Space Launch System Base Heating Test: Environments and Base Flow Physics

    NASA Technical Reports Server (NTRS)

    Mehta, Manish; Knox, Kyle S.; Seaford, C. Mark; Dufrene, Aaron T.

    2016-01-01

    The NASA Space Launch System (SLS) vehicle is composed of four RS-25 liquid oxygen-hydrogen rocket engines in the core-stage and two 5-segment solid rocket boosters and as a result six hot supersonic plumes interact within the aft section of the vehicle during flight. Due to the complex nature of rocket plume-induced flows within the launch vehicle base during ascent and a new vehicle configuration, sub-scale wind tunnel testing is required to reduce SLS base convective environment uncertainty and design risk levels. This hot-fire test program was conducted at the CUBRC Large Energy National Shock (LENS) II short-duration test facility to simulate flight from altitudes of 50 kft to 210 kft. The test program is a challenging and innovative effort that has not been attempted in 40+ years for a NASA vehicle. This paper discusses the various trends of base convective heat flux and pressure as a function of altitude at various locations within the core-stage and booster base regions of the two-percent SLS wind tunnel model. In-depth understanding of the base flow physics is presented using the test data, infrared high-speed imaging and theory. The normalized test design environments are compared to various NASA semi-empirical numerical models to determine exceedance and conservatism of the flight scaled test-derived base design environments. Brief discussion of thermal impact to the launch vehicle base components is also presented.

  5. Screening for Tuberculosis at an Adult Education Center: Results of a Community-Based Participatory Process

    PubMed Central

    Weis, Jennifer A.; Olney, Marilynn W.; Alemán, Marty; Sullivan, Susan; Millington, Kendra; O'Hara, Connie; Nigon, Julie A.; Sia, Irene G.

    2011-01-01

    Objectives. We used a community-based participatory research (CBPR) approach to plan and implement free TB skin testing at an adult education center to determine the efficacy of CBPR with voluntary tuberculosis (TB) screening and the prevalence of TB infection among immigrant and refugee populations. Methods. We formed a CBPR partnership to address TB screening at an adult education center that serves a large immigrant and refugee population in Rochester, Minnesota. We conducted focus groups involving educators, health providers, and students of the education center, and used this input to implement TB education and TB skin testing among the center's students. Results. A total of 259 adult learners volunteered to be skin-tested in April 2009; 48 (18.5%) had positive TB skin tests. Conclusions. Our results imply that TB skin testing at adult education centers that serve large foreign-born populations may be effective. Our findings also show that a participatory process may enhance the willingness of foreign-born persons to participate in TB skin-testing efforts. PMID:21653249

  6. Object-based classification of earthquake damage from high-resolution optical imagery using machine learning

    NASA Astrophysics Data System (ADS)

    Bialas, James; Oommen, Thomas; Rebbapragada, Umaa; Levin, Eugene

    2016-07-01

    Object-based approaches in the segmentation and classification of remotely sensed images yield more promising results compared to pixel-based approaches. However, the development of an object-based approach presents challenges in terms of algorithm selection and parameter tuning. Subjective methods are often used, but yield less than optimal results. Objective methods are warranted, especially for rapid deployment in time-sensitive applications, such as earthquake damage assessment. Herein, we used a systematic approach in evaluating object-based image segmentation and machine learning algorithms for the classification of earthquake damage in remotely sensed imagery. We tested a variety of algorithms and parameters on post-event aerial imagery for the 2011 earthquake in Christchurch, New Zealand. Results were compared against manually selected test cases representing different classes. In doing so, we can evaluate the effectiveness of the segmentation and classification of different classes and compare different levels of multistep image segmentations. Our classifier is compared against recent pixel-based and object-based classification studies for postevent imagery of earthquake damage. Our results show an improvement against both pixel-based and object-based methods for classifying earthquake damage in high resolution, post-event imagery.

  7. Guidance for Classifying Studies Conducted Using the OECD Test Guideline 223 (TG223) (Acute Avian Oral Sequential Dose Study)

    EPA Pesticide Factsheets

    Guidance based on comparison of results from the TG223 validation studies to results from avian acute oral studies previously submitted to EPA for two test chemicals following EPA's 850.2100 (public draft) guidelines.

  8. DEIVA: a web application for interactive visual analysis of differential gene expression profiles.

    PubMed

    Harshbarger, Jayson; Kratz, Anton; Carninci, Piero

    2017-01-07

    Differential gene expression (DGE) analysis is a technique to identify statistically significant differences in RNA abundance for genes or arbitrary features between different biological states. The result of a DGE test is typically further analyzed using statistical software, spreadsheets or custom ad hoc algorithms. We identified a need for a web-based system to share DGE statistical test results, and locate and identify genes in DGE statistical test results with a very low barrier of entry. We have developed DEIVA, a free and open source, browser-based single page application (SPA) with a strong emphasis on being user friendly that enables locating and identifying single or multiple genes in an immediate, interactive, and intuitive manner. By design, DEIVA scales with very large numbers of users and datasets. Compared to existing software, DEIVA offers a unique combination of design decisions that enable inspection and analysis of DGE statistical test results with an emphasis on ease of use.

  9. A comparison of clinic based dosimeters based on silica optical fibre and plastic optical fibre for in vivo dosimetry

    NASA Astrophysics Data System (ADS)

    Chen, Lingxia; O'Keeffe, Sinead; Woulfe, Peter; Lewis, Elfed

    2017-04-01

    Four sensors based on silica optical fibre and plastic optical fibre for clinical in-vivo dosimetry have been fabricated and tested on site at Galway Clinic. The initial comparison results have been attained for the four sensors when they have been irradiated with beam energies of 6 MV and 15 MV at different dose rates using a modern clinical linear accelerator (Linac) as the radiation source. According to the experimental test results, the sensors based on silica optical fibre exhibit greater sensitivity to the incident radiation beam than the sensors based on plastic optical fibre when they are exposed to identical irradiation conditions. The output intensity from the sensor based on silica fibre is 5 times higher than the sensor based on plastic optical fibre.

  10. Data base management study

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Data base management techniques and applicable equipment are described. Recommendations which will assist potential NASA data users in selecting and using appropriate data base management tools and techniques are presented. Classes of currently available data processing equipment ranging from basic terminals to large minicomputer systems were surveyed as they apply to the needs of potential SEASAT data users. Cost and capabilities projections for this equipment through 1985 were presented. A test of a typical data base management system was described, as well as the results of this test and recommendations to assist potential users in determining when such a system is appropriate for their needs. The representative system tested was UNIVAC's DMS 1100.

  11. QUEST/Ada (query utility environment for software testing of Ada: The development of a program analysis environment for Ada, task 1, phase 3

    NASA Technical Reports Server (NTRS)

    Brown, David B.

    1991-01-01

    The results of research and development efforts of the first six months of Task 1, Phase 3 of the project are presented. The goals of Phase 3 are: (1) to further refine the rule base and complete the comparative rule base evaluation; (2) to implement and evaluate a concurrency testing prototype; (3) to convert the complete (unit-level and concurrency) testing prototype to a workstation environment; and (4) to provide a prototype development document to facilitate the transfer of research technology to a working environment. These goals were partially met and the results are summarized.

  12. Proposal for a new categorization of aseptic processing facilities based on risk assessment scores.

    PubMed

    Katayama, Hirohito; Toda, Atsushi; Tokunaga, Yuji; Katoh, Shigeo

    2008-01-01

    Risk assessment of aseptic processing facilities was performed using two published risk assessment tools. Calculated risk scores were compared with experimental test results, including environmental monitoring and media fill run results, in three different types of facilities. The two risk assessment tools used gave a generally similar outcome. However, depending on the tool used, variations were observed in the relative scores between the facilities. For the facility yielding the lowest risk scores, the corresponding experimental test results showed no contamination, indicating that these ordinal testing methods are insufficient to evaluate this kind of facility. A conventional facility having acceptable aseptic processing lines gave relatively high risk scores. The facility showing a rather high risk score demonstrated the usefulness of conventional microbiological test methods. Considering the significant gaps observed in calculated risk scores and in the ordinal microbiological test results between advanced and conventional facilities, we propose a facility categorization based on risk assessment. The most important risk factor in aseptic processing is human intervention. When human intervention is eliminated from the process by advanced hardware design, the aseptic processing facility can be classified into a new risk category that is better suited for assuring sterility based on a new set of criteria rather than on currently used microbiological analysis. To fully benefit from advanced technologies, we propose three risk categories for these aseptic facilities.

  13. A Browser-Server-Based Tele-audiology System That Supports Multiple Hearing Test Modalities

    PubMed Central

    Yao, Daoyuan; Givens, Gregg

    2015-01-01

    Abstract Introduction: Millions of global citizens suffering from hearing disorders have limited or no access to much needed hearing healthcare. Although tele-audiology presents a solution to alleviate this problem, existing remote hearing diagnosis systems support only pure-tone tests, leaving speech and other test procedures unsolved, due to the lack of software and hardware to enable communication required between audiologists and their remote patients. This article presents a comprehensive remote hearing test system that integrates the two most needed hearing test procedures: a pure-tone audiogram and a speech test. Materials and Methods: This enhanced system is composed of a Web application server, an embedded smart Internet-Bluetooth® (Bluetooth SIG, Kirkland, WA) gateway (or console device), and a Bluetooth-enabled audiometer. Several graphical user interfaces and a relational database are hosted on the application server. The console device has been designed to support the tests and auxiliary communication between the local site and the remote site. Results: The study was conducted at an audiology laboratory. Pure-tone audiogram and speech test results from volunteers tested with this tele-audiology system are comparable with results from the traditional face-to-face approach. Conclusions: This browser-server–based comprehensive tele-audiology offers a flexible platform to expand hearing services to traditionally underserved groups. PMID:25919376

  14. Comparison of 3 in vivo methods for assessment of alcohol-based hand rubs.

    PubMed

    Edmonds-Wilson, Sarah; Campbell, Esther; Fox, Kyle; Macinga, David

    2015-05-01

    Alcohol-based hand rubs (ABHRs) are the primary method of hand hygiene in health-care settings. ICPs increasingly are assessing ABHR product efficacy data as improved products and test methods are developed. As a result, ICPs need better tools and recommendations for how to assess and compare ABHRs. Two ABHRs (70% ethanol) were tested according to 3 in vivo methods approved by ASTM International: E1174, E2755, and E2784. Log10 reductions were measured after a single test product use and after 10 consecutive uses at an application volume of 2 mL. The test method used had a significant influence on ABHR efficacy; however, in this study the test product (gel or foam) did not significantly influence efficacy. In addition, for all test methods, log10 reductions obtained after a single application were not predictive of results after 10 applications. Choice of test method can significantly influence efficacy results. Therefore, when assessing antimicrobial efficacy data of hand hygiene products, ICPs should pay close attention to the test method used, and ensure that product comparisons are made head to head in the same study using the same test methodology. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  15. Locomotive fuel tank structural safety testing program : passenger locomotive fuel tank jackknife derailment load test.

    DOT National Transportation Integrated Search

    2010-08-01

    This report presents the results of a passenger locomotive fuel tank load test simulating jackknife derailment (JD) load. The test is based on FRA requirements for locomotive fuel tanks in the Title 49, Code of Federal Regulations (CFR), Part 238, Ap...

  16. High-Temperature Cyclic Oxidation Data, Volume 1

    NASA Technical Reports Server (NTRS)

    Barrett, C. A.; Garlick, R. G.; Lowell, C. E.

    1984-01-01

    This first in a series of cyclic oxidation handbooks contains specific-weight-change-versus-time data and X-ray diffraction results derived from high-temperature cyclic tests on high-temperature, high-strength nickel-base gamma/gamma' and cobalt-base turbine alloys. Each page of data summarizes a complete test on a given alloy sample.

  17. GAS-PHASE AND PARTICULATE EMISSIONS DURING APPLICATION OF A WATER-BASED CLEANER WITH A HAND-PUMP SPRAYER

    EPA Science Inventory

    The paper gives results of tests in a controlled environment test room to measure concentrations of 2-butoxyethanol and particles during application of a cleaner to realistic surfaces (counter tops, glass, walls). (NOTE: Users of water-based cleaners applied with hand-pump spray...

  18. A Preliminary Assessment of Phase Separator Ground-Based and Reduced-Gravity Testing for ALS Systems

    NASA Technical Reports Server (NTRS)

    Hall, Nancy Rabel

    2006-01-01

    A viewgraph presentation of phase separator ground-based and reduced-gravity testing for Advanced Life Support (ALS) systems is shown. The topics include: 1) Multiphase Flow Technology Program; 2) Types of Separators; 3) MOBI Phase Separators; 4) Experiment set-up; and 5) Preliminary comparison/results.

  19. Role of Urine Drug Testing in the Current Opioid Epidemic.

    PubMed

    Mahajan, Gagan

    2017-12-01

    While the evidence for urine drug testing for patients on chronic opioid therapy is weak, the guidelines created by numerous medical societies and state and federal regulatory agencies recommend that it be included as one of the tools used to monitor patients for compliance with chronic opioid therapy. To get the most comprehensive results, clinicians should order both an immunoassay screen and confirmatory urine drug test. The immunoassay screen, which can be performed as an in-office point-of-care test or as a laboratory-based test, is a cheap and convenient study to order. Limitations of an immunoassay screen, however, include having a high threshold of detectability and only providing qualitative information about a select number of drug classes. Because of these restrictions, clinicians should understand that immunoassay screens have high false-positive and false-negative rates. Despite these limitations, though, the results can assist the clinician with making preliminary treatment decisions. In comparison, a confirmatory urine drug test, which can only be performed as a laboratory-based test, has a lower threshold of detectability and provides both qualitative and quantitative information. A urine drug test's greater degree of specificity allows for a relatively low false-negative and false-positive rate in contrast to an immunoassay screen. Like any other diagnostic test, an immunoassay screen and a confirmatory urine drug test both possess limitations. Clinicians must keep this in mind when interpreting an unexpected test result and consult with their laboratory when in doubt about the meaning of the test result to avoid making erroneous decisions that negatively impact both the patient and clinician.

  20. Impact of genetic counseling and Connexin-26 and Connexin-30 testing on deaf identity and comprehension of genetic test results in a sample of deaf adults: a prospective, longitudinal study.

    PubMed

    Palmer, Christina G S; Boudreault, Patrick; Baldwin, Erin E; Sinsheimer, Janet S

    2014-01-01

    Using a prospective, longitudinal study design, this paper addresses the impact of genetic counseling and testing for deafness on deaf adults and the Deaf community. This study specifically evaluated the effect of genetic counseling and Connexin-26 and Connexin-30 genetic test results on participants' deaf identity and understanding of their genetic test results. Connexin-26 and Connexin-30 genetic testing was offered to participants in the context of linguistically and culturally appropriate genetic counseling. Questionnaire data collected from 209 deaf adults at four time points (baseline, immediately following pre-test genetic counseling, 1-month following genetic test result disclosure, and 6-months after result disclosure) were analyzed. Four deaf identity orientations (hearing, marginal, immersion, bicultural) were evaluated using subscales of the Deaf Identity Development Scale-Revised. We found evidence that participants understood their specific genetic test results following genetic counseling, but found no evidence of change in deaf identity based on genetic counseling or their genetic test results. This study demonstrated that culturally and linguistically appropriate genetic counseling can improve deaf clients' understanding of genetic test results, and the formation of deaf identity was not directly related to genetic counseling or Connexin-26 and Connexin-30 genetic test results.

  1. Moderate wine consumption is associated with better cognitive test results: a 7 year follow up of 5033 subjects in the Tromsø Study.

    PubMed

    Arntzen, K A; Schirmer, H; Wilsgaard, T; Mathiesen, E B

    2010-01-01

    The impact of moderate alcohol consumption on cognitive function and dementia is unclear. We examined the relationship between consumption of different alcoholic beverages and cognitive function in a large population-based study. Subjects were 5033 stroke-free men and women who participated in a longitudinal population-based study in Tromsø, Norway. Alcohol consumption and other cardiovascular risk factors were measured at baseline and cognitive function was assessed after 7 years follow up with verbal memory test, digit-symbol coding test and tapping test. Moderate wine consumption was independently associated with better performance on all cognitive tests in both men and women. There was no consistent association between consumption of beer and spirits and cognitive test results. Alcohol abstention was associated with lower cognitive performance in women. Light-to-moderate wine consumption was associated with better performance on cognitive tests after 7 years follow up.

  2. Clinical and economic impact of the introduction of a nucleic acid amplification assay for Clostridium difficile.

    PubMed

    Guinta, Margaret M; Bunnell, Kristen; Harrington, Amanda; Bleasdale, Susan; Danziger, Larry; Wenzler, Eric

    2017-12-04

    The clinical outcomes and cost implications of a diagnostic shift from an EIA- to PCR-based assay for Clostridium difficile infection (CDI) have not been completely described in the literature. The impact of the PCR-based assay on the incidence and duration of CDI therapy was compared to the EIA assay for patients with a negative CDI diagnostic result. Secondary clinical and economic outcomes were also evaluated. Independent predictors of receipt of antibiotic therapy were assessed via logistic regression. 141 EIA and 140 PCR patients were included. Significantly more patients were started or continued on anti-CDI antibiotic therapy after a known negative assay result in the EIA group (26 patients vs. 8 patients, P = 0.002). Duration of antibiotic therapy after a known negative result was significantly shorter in the PCR group (1 vs. 4 days, P = 0.029) and a 23% reduction in the number of tests obtained per patient was observed (1.41 ± 0.86 vs. 1.82 ± 1.35, P = 0.007). The over fourfold difference in per-test cost of the EIA assay ($8.33 vs. $42.86, P < 0.0001) was offset by the overall medication costs required for the increased treatment in the EIA group ($546.60 vs. $188.96, P = 0.191). Utilization of the EIA-based CDI assay was associated with increased odds of CDI treatment after a negative test (aOR 4.71, 95% CI 1.93-11.46, P = 0.001). The transition from an EIA to PCR-based assay for diagnosing CDI resulted in a significant decrease in the number of patients treated and the duration of treatment in response to a negative test result. This significant decrease in treatment resulted in decreased costs offsetting the utilization of a more expensive molecular test for patients with a negative CDI diagnostic result.

  3. Sequential Objective Structured Clinical Examination based on item response theory in Iran.

    PubMed

    Hejri, Sara Mortaz; Jalili, Mohammad

    2017-01-01

    In a sequential objective structured clinical examination (OSCE), all students initially take a short screening OSCE. Examinees who pass are excused from further testing, but an additional OSCE is administered to the remaining examinees. Previous investigations of sequential OSCE were based on classical test theory. We aimed to design and evaluate screening OSCEs based on item response theory (IRT). We carried out a retrospective observational study. At each station of a 10-station OSCE, the students' performance was graded on a Likert-type scale. Since the data were polytomous, the difficulty parameters, discrimination parameters, and students' ability were calculated using a graded response model. To design several screening OSCEs, we identified the 5 most difficult stations and the 5 most discriminative ones. For each test, 5, 4, or 3 stations were selected. Normal and stringent cut-scores were defined for each test. We compared the results of each of the 12 screening OSCEs to the main OSCE and calculated the positive and negative predictive values (PPV and NPV), as well as the exam cost. A total of 253 students (95.1%) passed the main OSCE, while 72.6% to 94.4% of examinees passed the screening tests. The PPV values ranged from 0.98 to 1.00, and the NPV values ranged from 0.18 to 0.59. Two tests effectively predicted the results of the main exam, resulting in financial savings of 34% to 40%. If stations with the highest IRT-based discrimination values and stringent cut-scores are utilized in the screening test, sequential OSCE can be an efficient and convenient way to conduct an OSCE.

  4. Test and evaluation of 23 electric vehicles for state-of-the-art assessment

    NASA Technical Reports Server (NTRS)

    Dustin, M. O.; Denington, R. J.

    1978-01-01

    Eleven of the electric vehicles were passenger cars and 12 were commercial vans. Tests were conducted in accordance with an ERDS test procedure which is based on the SAE J227a Test Procedure. Tests included range, acceleration, coast-down, and braking. The results of the tests are presented, and comments on reliability are made.

  5. United States Air Force F-35A Operational Basing Environmental Impact Statement. Volume 1

    DTIC Science & Technology

    2013-09-01

    Evaluation (FDE) program and Weapons School (WS) beddown, the F-22 designator was used. Subsequent testing , development, and deployment resulted in...Initial F-35A Operational Basing EIS Final, September 2013 contract to develop the JSF ( designated the F-35 Lightning II). Since then, testing of F...of the aircraft even with system failures. Throughout the design and testing process, safety initiatives took previous best practices for single

  6. Selective testing strategies for diagnosing group A streptococcal infection in children with pharyngitis: a systematic review and prospective multicentre external validation study

    PubMed Central

    Cohen, Jérémie F.; Cohen, Robert; Levy, Corinne; Thollot, Franck; Benani, Mohamed; Bidet, Philippe; Chalumeau, Martin

    2015-01-01

    Background: Several clinical prediction rules for diagnosing group A streptococcal infection in children with pharyngitis are available. We aimed to compare the diagnostic accuracy of rules-based selective testing strategies in a prospective cohort of children with pharyngitis. Methods: We identified clinical prediction rules through a systematic search of MEDLINE and Embase (1975–2014), which we then validated in a prospective cohort involving French children who presented with pharyngitis during a 1-year period (2010–2011). We diagnosed infection with group A streptococcus using two throat swabs: one obtained for a rapid antigen detection test (StreptAtest, Dectrapharm) and one obtained for culture (reference standard). We validated rules-based selective testing strategies as follows: low risk of group A streptococcal infection, no further testing or antibiotic therapy needed; intermediate risk of infection, rapid antigen detection for all patients and antibiotic therapy for those with a positive test result; and high risk of infection, empiric antibiotic treatment. Results: We identified 8 clinical prediction rules, 6 of which could be prospectively validated. Sensitivity and specificity of rules-based selective testing strategies ranged from 66% (95% confidence interval [CI] 61–72) to 94% (95% CI 92–97) and from 40% (95% CI 35–45) to 88% (95% CI 85–91), respectively. Use of rapid antigen detection testing following the clinical prediction rule ranged from 24% (95% CI 21–27) to 86% (95% CI 84–89). None of the rules-based selective testing strategies achieved our diagnostic accuracy target (sensitivity and specificity > 85%). Interpretation: Rules-based selective testing strategies did not show sufficient diagnostic accuracy in this study population. The relevance of clinical prediction rules for determining which children with pharyngitis should undergo a rapid antigen detection test remains questionable. PMID:25487666

  7. [Interpretation of false positive results of biochemical prenatal tests].

    PubMed

    Sieroszewski, Piotr; Słowakiewicz, Katarzyna; Perenc, Małgorzata

    2010-03-01

    Modern, non-invasive prenatal diagnostics based on biochemical and ultrasonographic markers of fetal defects allows us to calculate the risk of fetal chromosomal aneuploidies with high sensitivity and specificity An introduction of biochemical, non-invasive prenatal tests turned out to result in frequent false positive results of these tests in cases when invasive diagnostics does not confirm fetal defects. However prospective analysis of these cases showed numerous complications in the third trimester of the pregnancies.

  8. A Prospective Blinded Evaluation of Urine-DNA Testing for Detection of Urothelial Bladder Carcinoma in Patients with Gross Hematuria.

    PubMed

    Dahmcke, Christina M; Steven, Kenneth E; Larsen, Louise K; Poulsen, Asger L; Abdul-Al, Ahmad; Dahl, Christina; Guldberg, Per

    2016-12-01

    Retrospective studies have provided proof of principle that bladder cancer can be detected by testing for the presence of tumor DNA in urine. We have conducted a prospective blinded study to determine whether a urine-based DNA test can replace flexible cystoscopy in the initial assessment of gross hematuria. A total of 475 consecutive patients underwent standard urological examination including flexible cystoscopy and computed tomography urography, and provided urine samples immediately before (n=461) and after (n=444) cystoscopy. Urine cells were collected using a filtration device and tested for eight DNA mutation and methylation biomarkers. Clinical evaluation identified 99 (20.8%) patients with urothelial bladder tumors. With this result as a reference and based on the analysis of all urine samples, the DNA test had a sensitivity of 97.0%, a specificity of 76.9%, a positive predictive value of 52.5%, and a negative predictive value of 99.0%. In three patients with a positive urine-DNA test without clinical evidence of cancer, a tumor was detected at repeat cystoscopy within 16 mo. Our results suggest that urine-DNA testing can be used to identify a large subgroup of patients with gross hematuria in whom cystoscopy is not required. We tested the possibility of using a urine-based DNA test to check for bladder cancer in patients with visible blood in the urine. Our results show that the test efficiently detects bladder cancer and therefore may be used to greatly reduce the number of patients who would need to undergo cystoscopy. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  9. Infrared detectors and test technology of cryogenic camera

    NASA Astrophysics Data System (ADS)

    Yang, Xiaole; Liu, Xingxin; Xing, Mailing; Ling, Long

    2016-10-01

    Cryogenic camera which is widely used in deep space detection cools down optical system and support structure by cryogenic refrigeration technology, thereby improving the sensitivity. Discussing the characteristics and design points of infrared detector combined with camera's characteristics. At the same time, cryogenic background test systems of chip and detector assembly are established. Chip test system is based on variable cryogenic and multilayer Dewar, and assembly test system is based on target and background simulator in the thermal vacuum environment. The core of test is to establish cryogenic background. Non-uniformity, ratio of dead pixels and noise of test result are given finally. The establishment of test system supports for the design and calculation of infrared systems.

  10. EHR based Genetic Testing Knowledge Base (iGTKB) Development

    PubMed Central

    2015-01-01

    Background The gap between a large growing number of genetic tests and a suboptimal clinical workflow of incorporating these tests into regular clinical practice poses barriers to effective reliance on advanced genetic technologies to improve quality of healthcare. A promising solution to fill this gap is to develop an intelligent genetic test recommendation system that not only can provide a comprehensive view of genetic tests as education resources, but also can recommend the most appropriate genetic tests to patients based on clinical evidence. In this study, we developed an EHR based Genetic Testing Knowledge Base for Individualized Medicine (iGTKB). Methods We extracted genetic testing information and patient medical records from EHR systems at Mayo Clinic. Clinical features have been semi-automatically annotated from the clinical notes by applying a Natural Language Processing (NLP) tool, MedTagger suite. To prioritize clinical features for each genetic test, we compared odds ratio across four population groups. Genetic tests, genetic disorders and clinical features with their odds ratios have been applied to establish iGTKB, which is to be integrated into the Genetic Testing Ontology (GTO). Results Overall, there are five genetic tests operated with sample size greater than 100 in 2013 at Mayo Clinic. A total of 1,450 patients who was tested by one of the five genetic tests have been selected. We assembled 243 clinical features from the Human Phenotype Ontology (HPO) for these five genetic tests. There are 60 clinical features with at least one mention in clinical notes of patients taking the test. Twenty-eight clinical features with high odds ratio (greater than 1) have been selected as dominant features and deposited into iGTKB with their associated information about genetic tests and genetic disorders. Conclusions In this study, we developed an EHR based genetic testing knowledge base, iGTKB. iGTKB will be integrated into the GTO by providing relevant clinical evidence, and ultimately to support development of genetic testing recommendation system, iGenetics. PMID:26606281

  11. E-Beam Capture Aid Drawing Based Modelling on Cell Biology

    NASA Astrophysics Data System (ADS)

    Hidayat, T.; Rahmat, A.; Redjeki, S.; Rahman, T.

    2017-09-01

    The objectives of this research are to find out how far Drawing-based Modeling assisted with E-Beam Capture could support student’s scientific reasoning skill using Drawing - based Modeling approach assisted with E-Beam Capture. The research design that is used for this research is the Pre-test and Post-test Design. The data collection of scientific reasoning skills is collected by giving multiple choice questions before and after the lesson. The data analysis of scientific reasoning skills is using scientific reasoning assessment rubric. The results show an improvement of student’s scientific reasoning in every indicator; an improvement in generativity which shows 2 students achieving high scores, 3 students in elaboration reasoning, 4 students in justification, 3 students in explanation, 3 students in logic coherency, 2 students in synthesis. The research result in student’s explanation reasoning has the highest number of students with high scores, which shows 20 students with high scores in the pre-test and 23 students in post-test and synthesis reasoning shows the lowest number, which shows 1 student in the pretest and 3 students in posttest. The research result gives the conclusion that Drawing-based Modeling approach assisted with E-Beam Capture could not yet support student’s scientific reasoning skills comprehensively.

  12. Fracture behaviors under pure shear loading in bulk metallic glasses

    NASA Astrophysics Data System (ADS)

    Chen, Cen; Gao, Meng; Wang, Chao; Wang, Wei-Hua; Wang, Tzu-Chiang

    2016-12-01

    Pure shear fracture test, as a special mechanical means, had been carried out extensively to obtain the critical information for traditional metallic crystalline materials and rocks, such as the intrinsic deformation behavior and fracture mechanism. However, for bulk metallic glasses (BMGs), the pure shear fracture behaviors have not been investigated systematically due to the lack of a suitable test method. Here, we specially introduce a unique antisymmetrical four-point bend shear test method to realize a uniform pure shear stress field and study the pure shear fracture behaviors of two kinds of BMGs, Zr-based and La-based BMGs. All kinds of fracture behaviors, the pure shear fracture strength, fracture angle and fracture surface morphology, are systematically analyzed and compared with those of the conventional compressive and tensile fracture. Our results indicate that both the Zr-based and La-based BMGs follow the same fracture mechanism under pure shear loading, which is significantly different from the situation of some previous research results. Our results might offer new enlightenment on the intrinsic deformation and fracture mechanism of BMGs and other amorphous materials.

  13. Fracture behaviors under pure shear loading in bulk metallic glasses.

    PubMed

    Chen, Cen; Gao, Meng; Wang, Chao; Wang, Wei-Hua; Wang, Tzu-Chiang

    2016-12-23

    Pure shear fracture test, as a special mechanical means, had been carried out extensively to obtain the critical information for traditional metallic crystalline materials and rocks, such as the intrinsic deformation behavior and fracture mechanism. However, for bulk metallic glasses (BMGs), the pure shear fracture behaviors have not been investigated systematically due to the lack of a suitable test method. Here, we specially introduce a unique antisymmetrical four-point bend shear test method to realize a uniform pure shear stress field and study the pure shear fracture behaviors of two kinds of BMGs, Zr-based and La-based BMGs. All kinds of fracture behaviors, the pure shear fracture strength, fracture angle and fracture surface morphology, are systematically analyzed and compared with those of the conventional compressive and tensile fracture. Our results indicate that both the Zr-based and La-based BMGs follow the same fracture mechanism under pure shear loading, which is significantly different from the situation of some previous research results. Our results might offer new enlightenment on the intrinsic deformation and fracture mechanism of BMGs and other amorphous materials.

  14. Radial SI latches vibration test data review

    NASA Technical Reports Server (NTRS)

    Harrison, P. M.; Smith, J. L.

    1984-01-01

    Dynamic testing of the Space Telescope Scientific Instrument Radial Latches was performed as specified by the designated test criteria. No structural failures were observed during the test. The alignment stability of the instrument simulator was within required tolerances after testing. Particulates were discovered around the latch bases, after testing, due to wearing at the B and C latch interface surfaces. This report covers criteria derivation, testing, and test results.

  15. Rocket-Based Combined Cycle Flowpath Testing for Modes 1 and 4

    NASA Technical Reports Server (NTRS)

    Rice, Tharen

    2002-01-01

    Under sponsorship of the NASA Glenn Research Center (NASA GRC), the Johns Hopkins University Applied Physics Laboratory (JHU/APL) designed and built a five-inch diameter, Rocket-Based Combined Cycle (RBCC) engine to investigate mode 1 and mode 4 engine performance as well as Mach 4 inlet performance. This engine was designed so that engine area and length ratios were similar to the NASA GRC GTX engine is shown. Unlike the GTX semi-circular engine design, the APL engine is completely axisymmetric. For this design, a traditional rocket thruster was installed inside of the scramjet flowpath, along the engine centerline. A three part test series was conducted to determine Mode I and Mode 4 engine performance. In part one, testing of the rocket thruster alone was accomplished and its performance determined (average Isp efficiency = 90%). In part two, Mode 1 (air-augmented rocket) testing was conducted at a nominal chamber pressure-to-ambient pressure ratio of 100 with the engine inlet fully open. Results showed that there was neither a thrust increment nor decrement over rocket-only thrust during Mode 1 operation. In part three, Mode 4 testing was conducted with chamber pressure-to-ambient pressure ratios lower than desired (80 instead of 600) with the inlet fully closed. Results for this testing showed a performance decrease of 20% as compared to the rocket-only testing. It is felt that these results are directly related to the low pressure ratio tested and not the engine design. During this program, Mach 4 inlet testing was also conducted. For these tests, a moveable centerbody was tested to determine the maximum contraction ratio for the engine design. The experimental results agreed with CFD results conducted by NASA GRC, showing a maximum geometric contraction ratio of approximately 10.5. This report details the hardware design, test setup, experimental results and data analysis associated with the aforementioned tests.

  16. Effects of an Inquiry-Based Short Intervention on State Test Anxiety in Comparison to Alternative Coping Strategies

    PubMed Central

    Krispenz, Ann; Dickhäuser, Oliver

    2018-01-01

    Background and Objectives: Test anxiety can have undesirable consequences for learning and academic achievement. The control-value theory of achievement emotions assumes that test anxiety is experienced if a student appraises an achievement situation as important (value appraisal), but feels that the situation and its outcome are not fully under his or her control (control appraisal). Accordingly, modification of cognitive appraisals is assumed to reduce test anxiety. One method aiming at the modification of appraisals is inquiry-based stress reduction. In the present study (N = 162), we assessed the effects of an inquiry-based short intervention on test anxiety. Design: Short-term longitudinal, randomized control trial. Methods: Focusing on an individual worry thought, 53 university students received an inquiry-based short intervention. Control participants reflected on their worry thought (n = 55) or were distracted (n = 52). Thought related test anxiety was assessed before, immediately after, and 2 days after the experimental treatment. Results: After the intervention as well as 2 days later, individuals who had received the inquiry-based intervention demonstrated significantly lower test anxiety than participants from the pooled control groups. Further analyses showed that the inquiry-based short intervention was more effective than reflecting on a worry thought but had no advantage over distraction. Conclusions: Our findings provide first experimental evidence for the effectiveness of an inquiry-based short intervention in reducing students’ test anxiety. PMID:29515507

  17. CFD assessment of the pollutant environment from RD-170 propulsion system testing

    NASA Technical Reports Server (NTRS)

    Wang, Ten-See; Mcconnaughey, Paul; Warsi, Saif; Chen, Yen-Sen

    1995-01-01

    Computational Fluid Dynamics (CFD) technology has been used to assess the exhaust plume pollutant environment of the RD-170 engine hot-firing on the F1 Test Stand at Marshall Space Flight Center. Researchers know that rocket engine hot-firing has the potential for forming thermal nitric oxides (NO(x)), as well as producing carbon monoxide (CO) when hydrocarbon fuels are used. Because of the complicated physics involved, however, little attempt has been made to predict the pollutant emissions from ground-based engine testing, except for simplified methods which can grossly underpredict and/or overpredict the pollutant formations in a test environment. The objective of this work, therefore, has been to develop a technology using CFD to describe the underlying pollutant emission physics from ground-based rocket engine testing. This resultant technology is based on a three-dimensional (3D), viscous flow, pressure-based CFD formulation, where wet CO and thermal NO finite-rate chemistry mechanisms are solved with a Penalty Function method. A nominal hot-firing of a RD-170 engine on the F1 stand has been computed. Pertinent test stand flow physics such as the multiple-nozzle clustered engine plume interaction, air aspiration from base and aspirator, plume mixing with entrained air that resulted in contaminant dilution and afterburning, counter-afterburning due to flame bucket water-quenching, plume impingement on the flame bucket, and restricted multiple-plume expansion and turning have been captured. The predicted total emission rates compared reasonably well with those of the existing hydrocarbon engine hot-firing test data.

  18. Changes in physical functioning in the Active Living Every Day program of the Active for Life Initiative®.

    PubMed

    Baruth, Meghan; Wilcox, Sara; Wegley, Stacy; Buchner, David M; Ory, Marcia G; Phillips, Alisa; Schwamberger, Karen; Bazzarre, Terry L

    2011-09-01

    Physical activity can prevent or delay the onset of physical functional limitations in older adults. There are limited data that evidence-based physical activity interventions can be successfully translated into community programs and result in similar benefits for physical functioning. The purpose of this study is to measure the effects of the Active Living Every Day program on physical functioning and physical functional limitations in a diverse sample of older adults. As a part of the Active for Life initiative, the Council on Aging of Southwestern Ohio implemented Active Living Every Day (ALED), a group-based lifestyle behavior change program designed to increase physical activity. Performance-based physical functioning tests (30-s Chair Stand Test, eight Foot Up-and-Go Test, Chair Sit-and-Reach Test, 30-Foot Walk Test) were administered to participants at baseline and posttest. Baseline to post-program changes in physical functioning and impairment status were examined with repeated measures analysis of covariance. Interactions tested whether change over time differed according to race/ethnicity, body mass index (BMI), and baseline impairment status. Participants significantly increased their performance in all four physical functioning tests. The percentage of participants classified as "impaired" according to normative data significantly decreased over time. Physical functioning improved regardless of BMI, race/ethnicity, or baseline impairment status. ALED is an example of an evidenced-based physical activity program that can be successfully translated into community programs and result in significant and clinically meaningful improvements in performance-based measures of physical functioning.

  19. Gene toxicity studies on titanium dioxide and zinc oxide nanomaterials used for UV-protection in cosmetic formulations.

    PubMed

    Landsiedel, Robert; Ma-Hock, Lan; Van Ravenzwaay, Ben; Schulz, Markus; Wiench, Karin; Champ, Samantha; Schulte, Stefan; Wohlleben, Wendel; Oesch, Franz

    2010-12-01

    Titanium dioxide and zinc oxide nanomaterials, used as UV protecting agents in sunscreens, were investigated for their potential genotoxicity in in vitro and in vivo test systems. Since standard OECD test methods are designed for soluble materials and genotoxicity testing for nanomaterials is still under revision, a battery of standard tests was used, covering different endpoints. Additionally, a procedure to disperse the nanomaterials in the test media and careful characterization of the dispersed test item was added to the testing methods. No genotoxicity was observed in vitro (Ames' Salmonella gene mutation test and V79 micronucleus chromosome mutation test) or in vivo (mouse bone marrow micronucleus test and Comet DNA damage assay in lung cells from rats exposed by inhalation). These results add to the still limited data base on genotoxicity test results with nanomaterials and provide congruent results of a battery of standard OECD test methods applied to nanomaterials.

  20. Developing Environmentally Responsible Behaviours Through the Implementation of Argumentation- and Problem-Based Learning Models

    NASA Astrophysics Data System (ADS)

    Fettahlıoğlu, Pınar; Aydoğdu, Mustafa

    2018-04-01

    The purpose of this research is to investigate the effect of using argumentation and problem-based learning approaches on the development of environmentally responsible behaviours among pre-service science teachers. Experimental activities were implemented for 14 weeks for 52 class hours in an environmental education class within a science teaching department. A mixed method was used as a research design; particularly, a special type of Concurrent Nested Strategy was applied. The quantitative portion was based on the one-group pre-test and post-test models, and the qualitative portion was based on the holistic multiple-case study method. The quantitative portion of the research was conducted with 34 third-year pre-service science teachers studying at a state university. The qualitative portion of the study was conducted with six pre-service science teachers selected among the 34 pre-service science teachers based on the pre-test results obtained from an environmentally responsible behaviour scale. t tests for dependent groups were used to analyse quantitative data. Both descriptive and content analyses of the qualitative data were performed. The results of the study showed that the use of the argumentation and problem-based learning approaches significantly contributed to the development of environmentally responsible behaviours among pre-service science teachers.

  1. On the clinical deformation of maxillary complete dentures. Influence of denture-base design and shape of denture-bearing tissue.

    PubMed

    el Ghazali, S; Glantz, P O; Strandman, E; Randow, K

    1989-04-01

    This paper aimed to study the influence of denture base design and the shape of the denture-supporting area on the functional deformation of maxillary complete dentures. Six strain-gauged duplicate maxillary dentures were made for the study of two test subjects with different shapes of the palatal vault. Each subject was supplied with two polymethyl methacrylate dentures, one with a 1-mm-thick palatal base and the other 2 mm thick. A third denture was constructed with a cobalt-chromium base. The functional loading tests included maximum biting and the chewing of the food test samples. An analysis based on chewing time and total number of chewing cycles per test piece was also made. The results showed that surface straining is highly complex at the anterior part of the maxillary dentures constructed from polymethyl methacrylate and that increasing the denture thickness per se might not be accompanied by a reduction of strain. The results also suggest that high thrust to the supporting tissue is produced with high palatal vault dentures made in polymethyl methacrylate. The study proposes that cobalt-chromium bases may be used in maxillary dentures to reduce functional deformation and thrust to the supporting tissues at the anterior part of the maxilla.

  2. Design, Fabrication, and Testing of Brassboard Model ATCRBS Based Surface Trilateration Data Acquisition Subsystem

    DOT National Transportation Integrated Search

    1977-12-01

    Field test results are emphasized in this report, which also contains background information on Airport Surface Traffic Control (ASTC) and the contract objectives. The National Aviation Facilities Experiimental Center (NAFEC) field test series conclu...

  3. Design and implementation of a general and automatic test platform base on NI PXI system

    NASA Astrophysics Data System (ADS)

    Shi, Long

    2018-05-01

    Aiming at some difficulties of test equipment such as the short product life, poor generality and high development cost, a general and automatic test platform base on NI PXI system is designed in this paper, which is able to meet most test requirements of circuit boards. The test platform is devided into 5 layers, every layer is introduced in detail except for the "Equipment Under Test" layer. An output board of a track-side equipment, which is an important part of high speed train control system, is taken as an example to make the functional circuit test by the test platform. The results show that the test platform is easy to realize add-on functions development, automatic test, wide compatibility and strong generality.

  4. Automated spot defect characterization in a field portable night vision goggle test set

    NASA Astrophysics Data System (ADS)

    Scopatz, Stephen; Ozten, Metehan; Aubry, Gilles; Arquetoux, Guillaume

    2018-05-01

    This paper discusses a new capability developed for and results from a field portable test set for Gen 2 and Gen 3 Image Intensifier (I2) tube-based Night Vision Goggles (NVG). A previous paper described the test set and the automated and semi-automated tests supported for NVGs including a Knife Edge MTF test to replace the operator's interpretation of the USAF 1951 resolution chart. The major improvement and innovation detailed in this paper is the use of image analysis algorithms to automate the characterization of spot defects of I² tubes with the same test set hardware previously presented. The original and still common Spot Defect Test requires the operator to look through the NVGs at target of concentric rings; compare the size of the defects to a chart and manually enter the results into a table based on the size and location of each defect; this is tedious and subjective. The prior semi-automated improvement captures and displays an image of the defects and the rings; allowing the operator determine the defects with less eyestrain; while electronically storing the image and the resulting table. The advanced Automated Spot Defect Test utilizes machine vision algorithms to determine the size and location of the defects, generates the result table automatically and then records the image and the results in a computer-generated report easily usable for verification. This is inherently a more repeatable process that ensures consistent spot detection independent of the operator. Results of across several NVGs will be presented.

  5. Spinning Spacecraft Attitude Estimation Using Markley Variables: Filter Implementation And Results

    NASA Technical Reports Server (NTRS)

    Sedlak, Joseph E.

    2005-01-01

    Attitude estimation is often more difficult for spinning spacecraft than for three-axis stabilized platforms due to the need to follow rapidly-varying state vector elements and the lack of three-axis rate measurements from gyros. The estimation problem simplifies when torques are negligible and nutation has damped out, but the general case requires a sequential filter with dynamics propagation. This paper describes the implementation and test results for an extended Kalman filter for spinning spacecraft attitude and rate estimation based on a novel set of variables suggested in a paper by Markley [AAS93-3301 (referred to hereafter as Markley variables). Markley has demonstrated that the new set of variables provides a superior parameterization for numerical integration of the attitude dynamics for spinning or momentum-biased spacecraft. The advantage is that the Markley variables have fewer rapidly-varying elements than other representations such as the attitude quaternion and rate vector. A filter based on these variables was expected to show improved performance due to the more accurate numerical state propagation. However, for a variety of test cases, it has been found that the new filter, as currently implemented, does not perform significantly better than a quaternion-based filter that was developed and tested in parallel. This paper reviews the mathematical background for a filter based on Markley variables. It also describes some features of the implementation and presents test results. The test cases are based on a mission using magnetometer and Sun sensor data and gyro measurements on two axes normal to the spin axis. The orbit and attitude scenarios and spacecraft parameters are modeled after one of the THEMIS (Time History of Events and Macroscale Interactions during Substorms) probes. Several tests are presented that demonstrate the filter accuracy and convergence properties. The tests include torque-free motion with various nutation angles, large constant-torque attitude slews, sensor misalignments, large initial attitude and rate errors, and cases with low data frequency. It is found that the convergence is rapid, the radius of convergence is large, and the results are reasonably accurate even in the presence of unmodeled perturbations.

  6. Parents' Experience with Pediatric Microarray: Transferrable Lessons in the Era of Genomic Counseling.

    PubMed

    Hayeems, R Z; Babul-Hirji, R; Hoang, N; Weksberg, R; Shuman, C

    2016-04-01

    Advances in genome-based microarray and sequencing technologies hold tremendous promise for understanding, better-managing and/or preventing disease and disease-related risk. Chromosome microarray technology (array based comparative genomic hybridization [aCGH]) is widely utilized in pediatric care to inform diagnostic etiology and medical management. Less clear is how parents experience and perceive the value of this technology. This study explored parents' experiences with aCGH in the pediatric setting, focusing on how they make meaning of various types of test results. We conducted in-person or telephone-based semi-structured interviews with parents of 21 children who underwent aCGH testing in 2010. Transcripts were coded and analyzed thematically according to the principles of interpretive description. We learned that parents expect genomic tests to be of personal use; their experiences with aCGH results characterize this use as intrinsic in the test's ability to provide a much sought-after answer for their child's condition, and instrumental in its ability to guide care, access to services, and family planning. In addition, parents experience uncertainty regardless of whether aCGH results are of pathogenic, uncertain, or benign significance; this triggers frustration, fear, and hope. Findings reported herein better characterize the notion of personal utility and highlight the pervasive nature of uncertainty in the context of genomic testing. Empiric research that links pre-test counseling content and psychosocial outcomes is warranted to optimize patient care.

  7. 32 CFR 634.11 - Administrative due process for suspensions and revocations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., military or civilian police report of apprehension, chemical test results if completed, refusal to consent... preliminary breath tests results, and other pertinent evidence. Immediate suspension should not be based... pre-determined by the final action authority. (6) For civilian personnel, written notice of suspension...

  8. 32 CFR 634.11 - Administrative due process for suspensions and revocations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., military or civilian police report of apprehension, chemical test results if completed, refusal to consent... preliminary breath tests results, and other pertinent evidence. Immediate suspension should not be based... pre-determined by the final action authority. (6) For civilian personnel, written notice of suspension...

  9. 32 CFR 634.11 - Administrative due process for suspensions and revocations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., military or civilian police report of apprehension, chemical test results if completed, refusal to consent... preliminary breath tests results, and other pertinent evidence. Immediate suspension should not be based... pre-determined by the final action authority. (6) For civilian personnel, written notice of suspension...

  10. The Application of Problem-Based Learning in Mechanical Engineering

    NASA Astrophysics Data System (ADS)

    Putra, Z. A.; Dewi, M.

    2018-02-01

    The course of Technology and Material Testing prepare students with the ability to do a variety of material testing in the study of mechanical engineering. Students find it difficult to understand the materials to make them unable to carry out the material testing in accordance with the purpose of study. This happens because they knowledge is not adequately supported by the competence to find and construct learning experience. In this study, quasy experiment research method with pre-post-test with control group design was used. The subjects of the study were students divided in two groups; control and experiment with twenty-two students in each group. Study result: their grades showed no difference in between the pre-test or post-test in control group, but the difference in grade existed between the pre-test and post-test in experiment group. Yet, there is no significant difference in the study result on both groups. The researcher recommend that it is necessary to develop Problem-Based Learning that suits need analysis on D3 Program for Mechanical Engineering Department at the State University of Padang, to ensure the compatibility between Model of Study and problems and need. This study aims to analyze how Problem-Based Learning effects on the course of Technology and Material Testing for the students of D3 Program of Mechanical Engineering of the State University of Padang.

  11. Key parameters in testing biodegradation of bio-based materials in soil.

    PubMed

    Briassoulis, D; Mistriotis, A

    2018-09-01

    Biodegradation of plastics in soil is currently tested by international standard testing methods (e.g. ISO 17556-12 or ASTM D5988-12). Although these testing methods have been developed for plastics, it has been shown in project KBBPPS that they can be extended also to lubricants with small modifications. Reproducibility is a critical issue regarding biodegradation tests in the laboratory. Among the main testing variables are the soil types and nutrients available (mainly nitrogen). For this reason, the effect of the soil type on the biodegradation rates of various bio-based materials (cellulose and lubricants) was tested for five different natural soil types (loam, loamy sand, clay, clay-loam, and silt-loam organic). It was shown that use of samples containing 1 g of C in a substrate of 300 g of soil with the addition of 0.1 g of N as nutrient strongly improves the reproducibility of the test making the results practically independent of the soil type with the exception of the organic soil. The sandy soil was found to need addition of higher amount of nutrients to exhibit similar biodegradation rates as those achieved with the other soil types. Therefore, natural soils can be used for Standard biodegradation tests of bio-based materials yielding reproducible results with the addition of appropriate nutrients. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Factors associated with Chlamydia trachomatis testing in a high school based screening and previously in clinical practice: a cross-sectional study in Norway

    PubMed Central

    2013-01-01

    Background High school based chlamydia screening has been shown to increase uptake and detect hidden infections among sexually active adolescents. Our study aimed to: i) examine the proportions of 15–20 year-olds tested in a high school based screening and previously in clinical practice, ii) determine chlamydia prevalence according to testing pattern, and iii) examine factors associated with testing in the two settings. Methods A population based cross-sectional study was conducted in 5 high schools in Norway in 2009, using web-questionnaires and Chlamydia trachomatis PCR in first-void urine (800 girls/818 boys, mean age 17.2 years). Only sexually active participants at risk for chlamydia infections were included in the analyses. Crude and multivariable logistic regression models were applied with ‘clinic based testing’ and ‘school based screening’ as outcome variables. Results 56% of girls and 21% of boys reported previous clinic based testing. In the school based screening, 93% were tested with no gender difference. 42% of girls and 74% of boys were tested for the first time at school (‘school-only test’). Both girls with clinic based testing and girls with school-only test had high chlamydia prevalence (7.3% vs 7.2%). Boys with clinic based testing had twice the prevalence of those with school-only test (6.2% vs 3.0%, p = 0.01). Half of infections were detected in participants with school-only test. One-fifth were repeat infections. In multivariable analysis of girls and boys combined, female gender, older age, early sexual debut, no condom use at first and last intercourse, steady relationship, and higher number of lifetime partners increased the odds of clinic based testing. The odds of school based screening increased with male gender, academic affiliation, later sexual debut, condom use at first intercourse, and current urogenital symptoms in multivariable analysis. Conclusions More than half the girls had been tested prior to the school based screening and had high prevalence independent of previous clinic based testing. School screening was mostly associated with factors unknown to increase chlamydia infection risk, while clinic based testing was associated with traditional risk factors. The unusually high and equal participation between genders and the detection of a large chlamydia reservoir confirms the value of school based screening suggesting this approach to be further explored in Norway. PMID:23915415

  13. Test of Cure for Anogenital Gonorrhoea Using Modern RNA-Based and DNA-Based Nucleic Acid Amplification Tests: A Prospective Cohort Study.

    PubMed

    Wind, Carolien M; Schim van der Loeff, Maarten F; Unemo, Magnus; Schuurman, Rob; van Dam, Alje P; de Vries, Henry J C

    2016-06-01

    The use of nucleic acid amplification tests (NAATs) to diagnose Neisseria gonorrhoeae infections complicates the performance of a test of cure (TOC) to monitor treatment failure, if this is indicated. As evidence for the timing of TOC using modern NAATs is limited, we performed a prospective cohort study to assess time to clearance when using modern RNA- and DNA-based NAATs. We included patients with anogenital gonorrhoea visiting the Sexually Transmitted Infection Clinic Amsterdam from March through October 2014. After treatment with ceftriaxone mono- or dual therapy (with azithromycin or doxycycline), anal, vaginal, or urine samples were self-collected during 28 consecutive days, and analyzed using an RNA-based NAAT (Aptima Combo 2) and a DNA-based NAAT (Cobas 4800). Clearance was defined as 3 consecutive negative results, and blips as isolated positive results following clearance. We included 77 patients; 5 self-cleared gonorrhoea before treatment and 10 were lost to follow-up. Clearance rate of the remaining 62 patients was 100%. Median time to clearance was 2 days, with a range of 1-7 days for RNA-based NAAT and 1-15 days for DNA-based NAAT. The risk of finding a blip after clearance was 0.8% and 1.5%, respectively. One patient had a reinfection. If indicated, we recommend that TOC be performed for anogenital gonorrhoea at least 7 or 14 days after administering therapy, when using modern RNA- or DNA-based NAATs, respectively. When interpreting TOC results for possible treatment failure, both the occurrence of blips and a possible reinfection need to be taken into account. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  14. Report on an Assessment of the Application of EPP Results from the Strain Limit Evaluation Procedure to the Prediction of Cyclic Life Based on the SMT Methodology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jetter, R. I.; Messner, M. C.; Sham, T. -L.

    The goal of the proposed integrated Elastic Perfectly-Plastic (EPP) and Simplified Model Test (SMT) methodology is to incorporate an SMT data based approach for creep-fatigue damage evaluation into the EPP methodology to avoid the separate evaluation of creep and fatigue damage and eliminate the requirement for stress classification in current methods; thus greatly simplifying evaluation of elevated temperature cyclic service. This methodology should minimize over-conservatism while properly accounting for localized defects and stress risers. To support the implementation of the proposed methodology and to verify the applicability of the code rules, analytical studies and evaluation of thermomechanical test results continuedmore » in FY17. This report presents the results of those studies. An EPP strain limits methodology assessment was based on recent two-bar thermal ratcheting test results on 316H stainless steel in the temperature range of 405 to 7050C. Strain range predictions from the EPP evaluation of the two-bar tests were also evaluated and compared with the experimental results. The role of sustained primary loading on cyclic life was assessed using the results of pressurized SMT data from tests on Alloy 617 at 9500C. A viscoplastic material model was used in an analytic simulation of two-bar tests to compare with EPP strain limits assessments using isochronous stress strain curves that are consistent with the viscoplastic material model. A finite element model of a prior 304H stainless steel Oak Ridge National Laboratory (ORNL) nozzle-to-sphere test was developed and used for an EPP strain limits and creep-fatigue code case damage evaluations. A theoretical treatment of a recurring issue with convergence criteria for plastic shakedown illustrated the role of computer machine precision in EPP calculations.« less

  15. Content Abstract Classification Using Naive Bayes

    NASA Astrophysics Data System (ADS)

    Latif, Syukriyanto; Suwardoyo, Untung; Aldrin Wihelmus Sanadi, Edwin

    2018-03-01

    This study aims to classify abstract content based on the use of the highest number of words in an abstract content of the English language journals. This research uses a system of text mining technology that extracts text data to search information from a set of documents. Abstract content of 120 data downloaded at www.computer.org. Data grouping consists of three categories: DM (Data Mining), ITS (Intelligent Transport System) and MM (Multimedia). Systems built using naive bayes algorithms to classify abstract journals and feature selection processes using term weighting to give weight to each word. Dimensional reduction techniques to reduce the dimensions of word counts rarely appear in each document based on dimensional reduction test parameters of 10% -90% of 5.344 words. The performance of the classification system is tested by using the Confusion Matrix based on comparative test data and test data. The results showed that the best classification results were obtained during the 75% training data test and 25% test data from the total data. Accuracy rates for categories of DM, ITS and MM were 100%, 100%, 86%. respectively with dimension reduction parameters of 30% and the value of learning rate between 0.1-0.5.

  16. Assessment of Direct-to-Consumer Genetic Testing Policy in Korea Based on Consumer Preference.

    PubMed

    Jeong, Gicheol

    2017-01-01

    In June 2016, Korea permitted direct-to-consumer genetic testing (DTC-GT) on 42 genes. However, both the market and industry have not yet been fully activated. Considering the aforementioned context, this study provides important insights. The Korean DTC-GT policy assessment is based on consumer preference analysis using a discrete choice experiment. In August 2016, a web-based survey was conducted to collect data from 1,200 respondents. The estimation results show that consumers prefer a DTC-GT product that is cheap, tests various items or genes, offers accurate test results, and guarantees the confidentiality of all information. However, consumers are not entirely satisfied by current DTC-GT products due to the existence of insufficient and/or inadequate policies. First, the permitted testing of 42 genes is insufficient to satisfy consumers' curiosity regarding their genes. Second, the accuracy of the DTC-GT products has not been fully verified, assessed, and communicated to consumers. Finally, regulatory loopholes that allow information leaks in the DTC-GT process can occur. These findings imply that DTC-GT requires an improvement in government policy-making criteria and the implementation of practical measures to guarantee test accuracy and genetic information. © 2017 S. Karger AG, Basel.

  17. Stepping into the virtual unknown: feasibility study of a virtual reality-based test of ocular misalignment.

    PubMed

    Nesaratnam, N; Thomas, P; Vivian, A

    2017-10-01

    IntroductionDissociated tests of strabismus provide valuable information for diagnosis and monitoring of ocular misalignment in patients with normal retinal correspondence. However, they are vulnerable to operator error and rely on a fixed head position. Virtual reality headsets obviate the need for head fixation, while providing other clear theoretical advantages, including complete control over the illumination and targets presented for the patient's interaction.PurposeWe compared the performance of a virtual reality-based test of ocular misalignment to that of the traditional Lees screen, to establish the feasibility of using virtual reality technology in ophthalmic settings in the future.MethodsThree patients underwent a traditional Lees screen test, and a virtual reality headset-based test of ocular motility. The virtual reality headset-based programme consisted of an initial test to measure horizontal and vertical deviation, followed by a test for torsion.ResultsThe pattern of deviation obtained using the virtual reality-based test showed agreement with that obtained from the Lees screen for patients with a fourth nerve palsy, comitant esotropia, and restrictive thyroid eye disease.ConclusionsThis study reports the first use of a virtual reality headset in assessing ocular misalignment, and demonstrates that it is a feasible dissociative test of strabismus.

  18. Developing a magnetism conceptual survey and assessing gender differences in student understanding of magnetism

    NASA Astrophysics Data System (ADS)

    Li, Jing; Singh, Chandralekha

    2012-02-01

    We discuss the development of a research-based conceptual multiple-choice survey of magnetism. We also discuss the use of the survey to investigate gender differences in students' difficulties with concepts related to magnetism. We find that while there was no gender difference on the pre-test. However, female students performed significantly worse than male students when the survey was given as a post-test in traditionally taught calculus-based introductory physics courses with similar results in both the regular and honors versions of the course. In the algebra-based courses, the performance of female and male students has no statistical difference on the pre-test or the post-test.

  19. Measurement system for diffraction efficiency of convex gratings

    NASA Astrophysics Data System (ADS)

    Liu, Peng; Chen, Xin-hua; Zhou, Jian-kang; Zhao, Zhi-cheng; Liu, Quan; Luo, Chao; Wang, Xiao-feng; Tang, Min-xue; Shen, Wei-min

    2017-08-01

    A measurement system for diffraction efficiency of convex gratings is designed. The measurement system mainly includes four components as a light source, a front system, a dispersing system that contains a convex grating, and a detector. Based on the definition and measuring principle of diffraction efficiency, the optical scheme of the measurement system is analyzed and the design result is given. Then, in order to validate the feasibility of the designed system, the measurement system is set up and the diffraction efficiency of a convex grating with the aperture of 35 mm, the curvature-radius of 72mm, the blazed angle of 6.4°, the grating period of 2.5μm and the working waveband of 400nm-900nm is tested. Based on GUM (Guide to the Expression of Uncertainty in Measurement), the uncertainties in the measuring results are evaluated. The measured diffraction efficiency data are compared to the theoretical ones, which are calculated based on the grating groove parameters got by an atomic force microscope and Rigorous Couple Wave Analysis, and the reliability of the measurement system is illustrated. Finally, the measurement performance of the system is analyzed and tested. The results show that, the testing accuracy, the testing stability and the testing repeatability are 2.5%, 0.085% and 3.5% , respectively.

  20. An analysis of the static load test on single square pile of 40x40 cm2, using finite element method in Rusunawa project, Jatinegara, Jakarta

    NASA Astrophysics Data System (ADS)

    Harasid, Harun; Roesyanto; Iskandar, Rudi; Silalahi, Sofyan A.

    2018-03-01

    Piling Foundation is one of the foundations which is used to penetrate its load through soil layer. The power carried by the piling is obtained from the end bearing capacity, that is, the compressive end piling and friction bearing capacity obtained from friction bearing and adhesive capacity between the piling and the soil around it. The investigation on the Standard Penetration Test is aimed to get the description of soil layer, based on the type and color of soil through visual observation, and soil characteristics. SPT data can be used to calculate bearing capacity. Besides investigating the SPT, this study is also been equipped by taking the samples in laboratory and loading test on the piling and Ducth Cone Penetrometer (DCP) data to confirm its bearing capacity. This study analyzed bearing capacity and settlement in the square pile of 40X40 cm in diameter in a single pile or grouped, using an empirical method, AllPile program, Plaxis program, and comparing the result with interpreting its loading test in the foundation of Rusunawa project, Jatinegara, Jakarta. The analysis was been done by using the data on soil investigation and laboratory by comparing them with Mohr-Coulomb soil model. Ultimate bearing capacity from the SPT data in the piling of 15.4 meters was 189.81 tons and the parameter of soil shear strength was 198.67 tons. The sander point, based on Aoki and De Alencar bearing capacity was 276.241 tons and based on Mayerhoff it was 305.49 tons. Based on the loading test of bearing capacity, unlimited bearing capacity for the three methods was Davisson (260 tons), Mazurkiewich (270 tons), and Chin (250 tons). The efficiency of grouped piles according to Converse-Library Equation method = 0.73, according to Los Angeles Group Action Equation method = 0.59, and according to Sheila-Keeny method = 0.94. Bearing capacity based on piling strength was 221.76 tons, bearing capacity based on calendaring data was 201.71 tons, and lateral bearing capacity of a single piling foundation was 129.6 kN (12.96 tons). When the maximum load (280 tons) was been given, more decrease occurred in the Maintained load test of 21.00 mm and Quick Load Test method of 20.67 mm, compared with the result of Load Test in the field of 18.74 mm. Based on ASTM D1143/81, the permitted value was 25.40 mm. Therefore, based on that decreasing, it could be concluded that foundation piles were safe in the construction. The pore water pressure is highly influenced by time so that in Maintained Load Test and Quick Load Test, there was the disparity in the level of pore water pressure. Based on the result of the calculation, Quick Load Test showed that in pore water pressure was dissipated in its acceleration.

  1. The implementation of assessment model based on character building to improve students’ discipline and achievement

    NASA Astrophysics Data System (ADS)

    Rusijono; Khotimah, K.

    2018-01-01

    The purpose of this research was to investigate the effect of implementing the assessment model based on character building to improve discipline and student’s achievement. Assessment model based on character building includes three components, which are the behaviour of students, the efforts, and student’s achievement. This assessment model based on the character building is implemented in science philosophy and educational assessment courses, in Graduate Program of Educational Technology Department, Educational Faculty, Universitas Negeri Surabaya. This research used control group pre-test and post-test design. Data collection method used in this research were observation and test. The observation was used to collect the data about the disciplines of the student in the instructional process, while the test was used to collect the data about student’s achievement. Moreover, the study applied t-test to the analysis of data. The result of this research showed that assessment model based on character building improved discipline and student’s achievement.

  2. Preliminary evaluation of the impact of a Web-based HIV testing programme in Abruzzo Region on the prevention of late HIV presentation and associated mortality.

    PubMed

    Polilli, Ennio; Sozio, Federica; Di Stefano, Paola; Clerico, Luigi; Di Iorio, Giancarlo; Parruti, Giustino

    2018-04-01

    This study aimed to analyze the efficacy of a Web-based testing programme in terms of the prevention of late HIV presentation. The clinical characteristics of patients diagnosed with HIV via the Web-based testing programme were compared to those of patients diagnosed in parallel via standard diagnostic care procedures. This study included the clinical and demographic data of newly diagnosed HIV patients enrolled at the study clinic between February 2014 and June 2017. These patients were diagnosed either via standard diagnostic procedures or as a result of the Web-based testing programme. Eighty-eight new cases of HIV were consecutively enrolled; their mean age was 39.1±13.0 years. Fifty-nine patients (67%) were diagnosed through standard diagnostic procedures and 29 (33%) patients came from the Web-based testing programme. Late presentation (62% vs. 34%, p=0.01) and AIDS-defining conditions at presentation (13 vs. 1, p=0.02) were significantly more frequent in the standard care group than in the Web-based group; four of 13 patients with AIDS diagnosed under standard diagnostic procedures died, versus none in the Web-based testing group (p<0.001). Web-based recruitment for voluntary and free HIV testing helped to diagnose patients with less advanced HIV disease and no risk of death, from all at-risk groups, in comparison with standard care testing. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Test module development to detect the flase call probe pins on microeprocessor test equipment

    NASA Astrophysics Data System (ADS)

    Tang, L. W.; Ong, N. R.; Mohamad, I. S. B.; Alcain, J. B.; Retnasamy, V.

    2017-09-01

    Probe pins are useful for electrical testing of microelectronic components, printed circuit board assembly (PCBA), microprocessors and other electronic devices due to it provides the conductivity test based on specific device circuit design. During the repeatable test runs, the load of test modules, contact failures and the current conductivity induces layer wear off all the tip of probe pins contact. Contamination will be build-up on probe pins and increased contact resistivity which results of cost loss and time loss for rectifying programs, rectifying testers and exchanging new probe pins. In this study, a resistivity approach will be developed to provide "Testing of Test Probes". The test module based on "Four-wire Ohm measurement" method with two alternative ways of applying power supply, that are 9V from a single power supply and 5V from Arduino UNO power supply were demonstrated to measure the small resistance value of microprocessor probe pin. A microcontroller with VEE Pro software was used to record the measurement data. The accuracy of both test modules were calibrated under different temperature conditions and result shows that 9V from a single power supply test module has higher measurement accuracy.

  4. Design and Analyses of a MEMS Based Resonant Magnetometer

    PubMed Central

    Ren, Dahai; Wu, Lingqi; Yan, Meizhi; Cui, Mingyang; You, Zheng; Hu, Muzhi

    2009-01-01

    A novel design of a MEMS torsional resonant magnetometer based on Lorentz force is presented and fabricated. The magnetometer consists of a silicon resonator, torsional beam, excitation coil, capacitance plates and glass substrate. Working in a resonant condition, the sensor’s vibration amplitude is converted into the sensing capacitance change, which reflects the outside magnetic flux-density. Based on the simulation, the key structure parameters are optimized and the air damping effect is estimated. The test results of the prototype are in accordance with the simulation results of the designed model. The resolution of the magnetometer can reach 30 nT. The test results indicate its sensitivity of more than 400 mV/μT when operating in a 10 Pa vacuum environment. PMID:22399981

  5. Comparative examination and validation of ELISA test systems for Salmonella typhimurium diagnosis of slaughtering pigs.

    PubMed

    Szabó, I; Scherer, K; Roesler, U; Appel, B; Nöckler, K; Hensel, A

    2008-05-10

    The most frequently isolated Salmonella serotype from pork in Germany is S. typhimurium, especially phagetype DT 104. The monitoring programs on Salmonella in swine are based on enzyme-linked immunoadsorbent assay (ELISA) detecting antibodies in serum or meat juice. These serological results are used to classify swine herds in three categories to assess the hygienic status of farm regarding Salmonella infection in pigs. The object of this study was the comparative evaluation of four indirect Salmonella ELISA tests approved in Germany to detect Salmonella typhimurium infection of swine. Three tests (A-C) are based on LPS-antigen and directed against specific IgG-antibodies. The fourth test (D) bases on a whole-cell-lysate antigen and discriminates between Salmonella specific IgA-, IgM- and IgG-antibodies. In a longitudinal study sixteen 6 weeks old weaning pigs were orally infected with S. typhimurium DT 104. During an observation period of 138d clinical and bacteriological parameters were monitored and serum samples obtained at regular intervals as well as meat juice samples taken at slaughter were examined by the respective ELISA systems. Study results reveal that all tested ELISA systems are able to detect S. typhimurium infection in pigs in both sample matrices, blood serum and meat juice whereas test D showed the highest sensitivity to detect Salmonella antibodies in pigs. The sensitivity to detect Salmonella antibodies varied between tests A and C according to the used cut-off (test specific cut-off vs. recommended surveillance cut-off) resulting in a change of seroprevalence and hence may influence the Salmonella status of the farm.

  6. Software testing

    NASA Astrophysics Data System (ADS)

    Price-Whelan, Adrian M.

    2016-01-01

    Now more than ever, scientific results are dependent on sophisticated software and analysis. Why should we trust code written by others? How do you ensure your own code produces sensible results? How do you make sure it continues to do so as you update, modify, and add functionality? Software testing is an integral part of code validation and writing tests should be a requirement for any software project. I will talk about Python-based tools that make managing and running tests much easier and explore some statistics for projects hosted on GitHub that contain tests.

  7. Comparison of a PfHRP2-based rapid diagnostic test and PCR for malaria in a low prevalence setting in rural southern Zambia: implications for elimination.

    PubMed

    Laban, Natasha M; Kobayashi, Tamaki; Hamapumbu, Harry; Sullivan, David; Mharakurwa, Sungano; Thuma, Philip E; Shiff, Clive J; Moss, William J

    2015-01-28

    Rapid diagnostic tests (RDTs) detecting histidine-rich protein 2 (PfHRP2) antigen are used to identify individuals with Plasmodium falciparum infection even in low transmission settings seeking to achieve elimination. However, these RDTs lack sensitivity to detect low-density infections, produce false negatives for P. falciparum strains lacking pfhrp2 gene and do not detect species other than P. falciparum. Results of a PfHRP2-based RDT and Plasmodium nested PCR were compared in a region of declining malaria transmission in southern Zambia using samples from community-based, cross-sectional surveys from 2008 to 2012. Participants were tested with a PfHRP2-based RDT and a finger prick blood sample was spotted onto filter paper for PCR analysis and used to prepare blood smears for microscopy. Species-specific, real-time, quantitative PCR (q-PCR) was performed on samples that tested positive either by microscopy, RDT or nested PCR. Of 3,292 total participants enrolled, 12 (0.4%) tested positive by microscopy and 42 (1.3%) by RDT. Of 3,213 (98%) samples tested by nested PCR, 57 (1.8%) were positive, resulting in 87 participants positive by at least one of the three tests. Of these, 61 tested positive for P. falciparum by q-PCR with copy numbers ≤ 2 x 10(3) copies/μL, 5 were positive for both P. falciparum and Plasmodium malariae and 2 were positive for P. malariae alone. RDT detected 32 (53%) of P. falciparum positives, failing to detect three of the dual infections with P. malariae. Among 2,975 participants enrolled during a low transmission period between 2009 and 2012, sensitivity of the PfHRP2-based RDT compared to nested PCR was only 17%, with specificity of >99%. The pfhrp gene was detected in 80% of P. falciparum positives; however, comparison of copy number between RDT negative and RDT positive samples suggested that RDT negatives resulted from low parasitaemia and not pfhrp2 gene deletion. Low-density P. falciparum infections not identified by currently used PfHRP2-based RDTs and the inability to detect non-falciparum malaria will hinder progress to further reduce malaria in low transmission settings of Zambia. More sensitive and specific diagnostic tests will likely be necessary to identify parasite reservoirs and achieve malaria elimination.

  8. Accounting for estimated IQ in neuropsychological test performance with regression-based techniques.

    PubMed

    Testa, S Marc; Winicki, Jessica M; Pearlson, Godfrey D; Gordon, Barry; Schretlen, David J

    2009-11-01

    Regression-based normative techniques account for variability in test performance associated with multiple predictor variables and generate expected scores based on algebraic equations. Using this approach, we show that estimated IQ, based on oral word reading, accounts for 1-9% of the variability beyond that explained by individual differences in age, sex, race, and years of education for most cognitive measures. These results confirm that adding estimated "premorbid" IQ to demographic predictors in multiple regression models can incrementally improve the accuracy with which regression-based norms (RBNs) benchmark expected neuropsychological test performance in healthy adults. It remains to be seen whether the incremental variance in test performance explained by estimated "premorbid" IQ translates to improved diagnostic accuracy in patient samples. We describe these methods, and illustrate the step-by-step application of RBNs with two cases. We also discuss the rationale, assumptions, and caveats of this approach. More broadly, we note that adjusting test scores for age and other characteristics might actually decrease the accuracy with which test performance predicts absolute criteria, such as the ability to drive or live independently.

  9. Development of an artificial neural network model for risk assessment of skin sensitization using human cell line activation test, direct peptide reactivity assay, KeratinoSens™ and in silico structure alert parameter.

    PubMed

    Hirota, Morihiko; Ashikaga, Takao; Kouzuki, Hirokazu

    2018-04-01

    It is important to predict the potential of cosmetic ingredients to cause skin sensitization, and in accordance with the European Union cosmetic directive for the replacement of animal tests, several in vitro tests based on the adverse outcome pathway have been developed for hazard identification, such as the direct peptide reactivity assay, KeratinoSens™ and the human cell line activation test. Here, we describe the development of an artificial neural network (ANN) prediction model for skin sensitization risk assessment based on the integrated testing strategy concept, using direct peptide reactivity assay, KeratinoSens™, human cell line activation test and an in silico or structure alert parameter. We first investigated the relationship between published murine local lymph node assay EC3 values, which represent skin sensitization potency, and in vitro test results using a panel of about 134 chemicals for which all the required data were available. Predictions based on ANN analysis using combinations of parameters from all three in vitro tests showed a good correlation with local lymph node assay EC3 values. However, when the ANN model was applied to a testing set of 28 chemicals that had not been included in the training set, predicted EC3s were overestimated for some chemicals. Incorporation of an additional in silico or structure alert descriptor (obtained with TIMES-M or Toxtree software) in the ANN model improved the results. Our findings suggest that the ANN model based on the integrated testing strategy concept could be useful for evaluating the skin sensitization potential. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Cold Helium Pressurization for Liquid Oxygen / Liquid Methane Propulsion Systems: Fully-Integrated Initial Hot-Fire Test Results

    NASA Technical Reports Server (NTRS)

    Morehead, R. L.; Atwell, M. J.; Melcher, J. C.; Hurlbert, E. A.

    2016-01-01

    A prototype cold helium active pressurization system was incorporated into an existing liquid oxygen (LOX) / liquid methane (LCH4) prototype planetary lander and hot-fire tested to collect vehicle-level performance data. Results from this hot-fire test series were used to validate integrated models of the vehicle helium and propulsion systems and demonstrate system effectiveness for a throttling lander. Pressurization systems vary greatly in complexity and efficiency between vehicles, so a pressurization performance metric was also developed as a means to compare different active pressurization schemes. This implementation of an active repress system is an initial sizing draft. Refined implementations will be tested in the future, improving the general knowledge base for a cryogenic lander-based cold helium system.

  11. Internet-based HIV and sexually transmitted infection testing in British Columbia, Canada: opinions and expectations of prospective clients.

    PubMed

    Hottes, Travis Salway; Farrell, Janine; Bondyra, Mark; Haag, Devon; Shoveller, Jean; Gilbert, Mark

    2012-03-06

    The feasibility and acceptability of Internet-based sexually transmitted infection (STI) testing have been demonstrated; however, few programs have included testing for human immunodeficiency virus (HIV). In British Columbia, Canada, a new initiative will offer online access to chlamydia, gonorrhea, syphilis, and HIV testing, integrated with existing clinic-based services. We presented the model to gay men and other men who have sex with men (MSM) and existing clinic clients through a series of focus groups. To identify perceived benefits, concerns, and expectations of a new model for Internet-based STI and HIV testing among potential end users. Participants were recruited through email invitations, online classifieds, and flyers in STI clinics. A structured interview guide was used. Focus groups were audio recorded, and an observer took detailed field notes. Analysts then listened to audio recordings to validate field notes. Data were coded and analyzed using a scissor-and-sort technique. In total, 39 people participated in six focus groups. Most were MSM, and all were active Internet users and experienced with STI/HIV testing. Perceived benefits of Internet-based STI testing included anonymity, convenience, and client-centered control. Salient concerns were reluctance to provide personal information online, distrust of security of data provided online, and the need for comprehensive pretest information and support for those receiving positive results, particularly for HIV. Suggestions emerged for mitigation of these concerns: provide up-front and detailed information about the model, ask only the minimal information required for testing, give positive results only by phone or in person, and ensure that those testing positive are referred for counseling and support. End users expected Internet testing to offer continuous online service delivery, from booking appointments, to transmitting information to the laboratory, to getting prescriptions. Most participants said they would use the service or recommend it to others. Those who indicated they would be unlikely to use it generally either lived near an STI clinic or routinely saw a family doctor with whom they were comfortable testing. Participants expected that the service would provide the greatest benefit to individuals who do not already have access to sensitive sexual health services, are reluctant to test due to stigma, or want to take immediate action (eg, because of a recent potential STI/HIV exposure). Internet-based STI/HIV testing has the potential to reduce barriers to testing, as a complement to existing clinic-based services. Trust in the new online service, however, is a prerequisite to client uptake and may be engendered by transparency of information about the model, and by accounting for concerns related to confidentiality, data usage, and provision of positive (especially HIV) results. Ongoing evaluation of this new model will be essential to its success and to the confidence of its users.

  12. Thermal Expert System (TEXSYS): Systems automony demonstration project, volume 1. Overview

    NASA Technical Reports Server (NTRS)

    Glass, B. J. (Editor)

    1992-01-01

    The Systems Autonomy Demonstration Project (SADP) produced a knowledge-based real-time control system for control and fault detection, isolation, and recovery (FDIR) of a prototype two-phase Space Station Freedom external active thermal control system (EATCS). The Thermal Expert System (TEXSYS) was demonstrated in recent tests to be capable of reliable fault anticipation and detection, as well as ordinary control of the thermal bus. Performance requirements were addressed by adopting a hierarchical symbolic control approach-layering model-based expert system software on a conventional, numerical data acquisition and control system. The model-based reasoning capabilities of TEXSYS were shown to be advantageous over typical rule-based expert systems, particularly for detection of unforeseen faults and sensor failures. Volume 1 gives a project overview and testing highlights. Volume 2 provides detail on the EATCS test bed, test operations, and online test results. Appendix A is a test archive, while Appendix B is a compendium of design and user manuals for the TEXSYS software.

  13. Diagnostic accuracy of tablet-based software for the detection of concussion.

    PubMed

    Yang, Suosuo; Flores, Benjamin; Magal, Rotem; Harris, Kyrsti; Gross, Jonathan; Ewbank, Amy; Davenport, Sasha; Ormachea, Pablo; Nasser, Waleed; Le, Weidong; Peacock, W Frank; Katz, Yael; Eagleman, David M

    2017-01-01

    Despite the high prevalence of traumatic brain injuries (TBI), there are few rapid and straightforward tests to improve its assessment. To this end, we developed a tablet-based software battery ("BrainCheck") for concussion detection that is well suited to sports, emergency department, and clinical settings. This article is a study of the diagnostic accuracy of BrainCheck. We administered BrainCheck to 30 TBI patients and 30 pain-matched controls at a hospital Emergency Department (ED), and 538 healthy individuals at 10 control test sites. We compared the results of the tablet-based assessment against physician diagnoses derived from brain scans, clinical examination, and the SCAT3 test, a traditional measure of TBI. We found consistent distributions of normative data and high test-retest reliability. Based on these assessments, we defined a composite score that distinguishes TBI from non-TBI individuals with high sensitivity (83%) and specificity (87%). We conclude that our testing application provides a rapid, portable testing method for TBI.

  14. Potential of phytoceuticals to affect antibiotic residue detection tests in cow milk in a randomised trial

    PubMed Central

    Mullen, Keena AE; Beasley, Erin; Rizzo, Julio Q; Washburn, Steven P; Baynes, Ronald E; Mason, Sharon E

    2017-01-01

    Mastitis is a costly disease for dairy farmers. Some dairy farmers use herbal products, or phytoceuticals, to treat mastitis. Phytoceuticals have not been approved for this use by the United States Food and Drug Administration, and have not been tested to determine how they impact antibiotic residue detection testing. The current study tested the potential for phytoceuticals to cause positive results on two milk antibiotic residue screening tests, the Delvotest P and Charm SL Beta-lactam test, or to interfere with the detection of antibiotics by these tests. The three phytoceuticals tested were labelled for intramammary, topical or intravulvar administration. Testing was performed in vitro using the products diluted in milk obtained from healthy organic dairy cows. Phytoceuticals were tested at concentrations ranging from 1.5 per cent to 100 per cent. Concentration levels were replicated at least twice on each milk antibiotic residue screening test. The Delvotest P is based on detection of bacterial inhibitors and no positive results were obtained for any product at concentrations less than 50 per cent. The Charm SL Beta-lactam test uses a receptor for the detection of beta-lactam antibiotics and no concentration of phytoceuticals caused an interference with these tests. Based on dilution of the products in bovine milk at physiologically achievable levels, phytoceutical products tested at levels expected after treatment do not cause positive test results for the Delvotest P nor do they interfere with the Charm SL Beta-lactam test in detection of various antibiotics. PMID:28890791

  15. Irradiation embrittlement characterization of the EUROFER 97 material

    NASA Astrophysics Data System (ADS)

    Kytka, M.; Brumovsky, M.; Falcnik, M.

    2011-02-01

    The paper summarizes original results of irradiation embrittlement study of EUROFER 97 material that has been proposed as one candidate of structural materials for future fusion energy systems and GEN IV. Test specimens were manufactured from base metal as well as from weld metal and tested in initial unirradiated condition and also after neutron irradiation. Irradiation embrittlement was characterized by testing of toughness properties at transition temperature region - static fracture toughness and dynamic fracture toughness properties, all in sub-size three-point bend specimens (27 × 4 × 3 mm 3). Testing and evaluation was performed in accordance with ASTM and ESIS standards, fracture toughness KJC and KJd data were also evaluated with the "Master curve" approach. Moreover, J- R dependencies were determined and analyzed. The paper compares unirradiated and irradiated properties as well as changes in transition temperature shifts of these material parameters. Discussion about the correlation between static and dynamic properties is also given. Results from irradiation of EUROFER 97 show that this steel - base metal as well as weld metal - is suitable as a structural material for reactor pressure vessels of innovative nuclear systems - fusion energy systems and GEN IV. Transition temperature shifts after neutron irradiation by 2.5 dpa dose show a good agreement in the case of EUROFER 97 base material for both static and dynamic fracture toughness tests. From the results it can be concluded that there is a low sensitivity of weld metal to neutron irradiation embrittlement in comparison with EUROFER 97 base metal.

  16. Diagnosing Flu

    MedlinePlus

    ... your symptoms and their clinical judgment. Will my health care provider test me for flu if I have flu-like ... with flu symptoms are not tested because the test results usually do not change how you are treated. Your health care provider may diagnose you with flu based on ...

  17. Scale-Up of an Human Papillomavirus Testing Implementation Program in El Salvador.

    PubMed

    Cremer, Miriam; Maza, Mauricio; Alfaro, Karla; Morales Velado, Mario; Felix, Juan; Castle, Philip E; Kim, Jane; Gage, Julia C

    2017-01-01

    The Cervical Cancer Prevention in El Salvador is a demonstration project to introduce a lower-cost human papillomavirus (HPV)-DNA test into a public sector project. Started in October 2012, The Cervical Cancer Prevention in El Salvador consists of 3 phases and will ultimately screen 30,000 women. Results of phase 2 of the project are presented. The objective of this project was to compare colposcopy and noncolposcopy-based management for HPV-positive women. In phase 2, a total of 8,050 women, aged 30 to 49 years, were screened; 6,761 provided both self- and provider-collected specimens and 1,289 provided only provider-testing specimens. HPV results from self-collected specimens were not used in clinical management decisions. Women with provider-collected HPV-positive results were treated based on the strategy assigned to their community; the strategy was colposcopy management (CM) or screen-and-treat (ST) management if they were cryotherapy eligible or colposcopy if not eligible. Outcomes were assessed 6 months after screening. Overall, 489 (12.3%) of 3,963 women receiving CM and 465 (11.4%) of 4,087 women receiving ST tested HPV positive. In the CM cohort, 216 (44.2%) of 489 completed their intervention (203 treated, 11 diagnosed negative, 2 pregnant). In the ST cohort, 411 (88.4%) of 465 completed their intervention (407 treated, 2 diagnosed negative, 1 pregnant). Overall agreement between HPV test results from self-collected and provider-collected specimens was 93.7%, with a κ value of 0.70 (95% CI = 0.68-0.73). Human papillomavirus testing with ST management resulted in an approximately twice completion rate compared with CM management. Agreement between self- and provider-based sampling was good and might be used to extend screening to women in areas that are more difficult to reach.

  18. Evaluation of Alternative Altitude Scaling Methods for Thermal Ice Protection System in NASA Icing Research Tunnel

    NASA Technical Reports Server (NTRS)

    Lee, Sam; Addy, Harold; Broeren, Andy P.; Orchard, David M.

    2017-01-01

    A test was conducted at NASA Icing Research Tunnel to evaluate altitude scaling methods for thermal ice protection system. Two scaling methods based on Weber number were compared against a method based on the Reynolds number. The results generally agreed with the previous set of tests conducted in NRCC Altitude Icing Wind Tunnel. The Weber number based scaling methods resulted in smaller runback ice mass than the Reynolds number based scaling method. The ice accretions from the Weber number based scaling method also formed farther upstream. However there were large differences in the accreted ice mass between the two Weber number based scaling methods. The difference became greater when the speed was increased. This indicated that there may be some Reynolds number effects that isnt fully accounted for and warrants further study.

  19. Validity of Scientific Based Chemistry Android Module to Empower Science Process Skills (SPS) in Solubility Equilibrium

    NASA Astrophysics Data System (ADS)

    Antrakusuma, B.; Masykuri, M.; Ulfa, M.

    2018-04-01

    Evolution of Android technology can be applied to chemistry learning, one of the complex chemistry concept was solubility equilibrium. this concept required the science process skills (SPS). This study aims to: 1) Characteristic scientific based chemistry Android module to empowering SPS, and 2) Validity of the module based on content validity and feasibility test. This research uses a Research and Development approach (RnD). Research subjects were 135 s1tudents and three teachers at three high schools in Boyolali, Central of Java. Content validity of the module was tested by seven experts using Aiken’s V technique, and the module feasibility was tested to students and teachers in each school. Characteristics of chemistry module can be accessed using the Android device. The result of validation of the module contents got V = 0.89 (Valid), and the results of the feasibility test Obtained 81.63% (by the student) and 73.98% (by the teacher) indicates this module got good criteria.

  20. BETA: Behavioral testability analyzer and its application to high-level test generation and synthesis for testability. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Chen, Chung-Hsing

    1992-01-01

    In this thesis, a behavioral-level testability analysis approach is presented. This approach is based on analyzing the circuit behavioral description (similar to a C program) to estimate its testability by identifying controllable and observable circuit nodes. This information can be used by a test generator to gain better access to internal circuit nodes and to reduce its search space. The results of the testability analyzer can also be used to select test points or partial scan flip-flops in the early design phase. Based on selection criteria, a novel Synthesis for Testability approach call Test Statement Insertion (TSI) is proposed, which modifies the circuit behavioral description directly. Test Statement Insertion can also be used to modify circuit structural description to improve its testability. As a result, Synthesis for Testability methodology can be combined with an existing behavioral synthesis tool to produce more testable circuits.

  1. Development of an unsteady aerodynamics model to improve correlation of computed blade stresses with test data

    NASA Technical Reports Server (NTRS)

    Gangwani, S. T.

    1985-01-01

    A reliable rotor aeroelastic analysis operational that correctly predicts the vibration levels for a helicopter is utilized to test various unsteady aerodynamics models with the objective of improving the correlation between test and theory. This analysis called Rotor Aeroelastic Vibration (RAVIB) computer program is based on a frequency domain forced response analysis which utilizes the transfer matrix techniques to model helicopter/rotor dynamic systems of varying degrees of complexity. The results for the AH-1G helicopter rotor were compared with the flight test data during high speed operation and they indicated a reasonably good correlation for the beamwise and chordwise blade bending moments, but for torsional moments the correlation was poor. As a result, a new aerodynamics model based on unstalled synthesized data derived from the large amplitude oscillating airfoil experiments was developed and tested.

  2. Extending LMS to Support IRT-Based Assessment Test Calibration

    NASA Astrophysics Data System (ADS)

    Fotaris, Panagiotis; Mastoras, Theodoros; Mavridis, Ioannis; Manitsaris, Athanasios

    Developing unambiguous and challenging assessment material for measuring educational attainment is a time-consuming, labor-intensive process. As a result Computer Aided Assessment (CAA) tools are becoming widely adopted in academic environments in an effort to improve the assessment quality and deliver reliable results of examinee performance. This paper introduces a methodological and architectural framework which embeds a CAA tool in a Learning Management System (LMS) so as to assist test developers in refining items to constitute assessment tests. An Item Response Theory (IRT) based analysis is applied to a dynamic assessment profile provided by the LMS. Test developers define a set of validity rules for the statistical indices given by the IRT analysis. By applying those rules, the LMS can detect items with various discrepancies which are then flagged for review of their content. Repeatedly executing the aforementioned procedure can improve the overall efficiency of the testing process.

  3. Investigation of Perception in Electric Field based on Scholastic Tests of National Institute for Educational Policy Research

    NASA Astrophysics Data System (ADS)

    Eguchi, Kei; Sugimura, Tatsuya; Watanabe, Toshiya; Kurebayashi, Shuji

    To investigate the perception of science and technology of university students, the scholastic test concerning electric field was conducted in this paper. The scholastic test, which was conducted to university students, is based on the scholastic test provided by the National Institute for Educational Policy Research of Japan's Curriculum Research Center. The result of the scholastic test showed that 1. For the questions related to “A4(i): Maintenance check and prevention of accidents of equipment” in the junior high school government guidelines for teaching, the percentage of correct answer was the lowest and 2. Not only liberal arts course students but also science course students do not have sufficient perception concerning the capability of “Device and Creativity”, because the percentage of correct answer to the questions concerning “Device and Creativity” was about 70%. The results of this study will give us the directivity of electricity education.

  4. Corrosion Behavior of PEO Coatings Formed on AZ31 Alloy in Phosphate-Based Electrolytes with Calcium Acetate Additive

    NASA Astrophysics Data System (ADS)

    Ziyaei, E.; Atapour, M.; Edris, H.; Hakimizad, A.

    2017-07-01

    The PEO coating started on magnesium AZ31 using a unipolar DC power source. The coating was generated in the electrolyte based on Na3PO4·12H2O and KOH with calcium acetate as additive. The x-ray diffraction method showed some phases containing calcium and phosphate, which was created in the presence of additive. Also, the EDS tests of the sample's surfaces proved the existence of calcium on the surface. Based on the electrochemical tests results, the most corrosion resistance belongs to the sample with calcium acetate additive. In fact, the results of the EIS tests showed the coating with calcium acetate has the highest resistance but the lowest capacitance. However, this state belongs to the surface morphology, the lower porosity, and surface chemical composition.

  5. Regeneration of Exhausted Arsenic Adsorptive media of a Full Scale Treatment System

    EPA Science Inventory

    This presentation will describe the method and results of laboratory tests showing the feasibility of regenerating exhausted, iron-based, adsorptive media and the results of a follow up regeneration test at a full scale system in Twentynine Palms CA. The laboratory studies on se...

  6. The "Anatomy" of a Performance-Enhancing Drug Test in Sports

    ERIC Educational Resources Information Center

    Werner, T. C.

    2012-01-01

    The components of a performance-enhancing drug (PED) test in sports include sample selection, collection, establishing sample integrity, sample pretreatment, analyte detection, data evaluation, reporting results, and action taken based on the result. Undergraduate curricula generally focus on the detection and evaluation steps of an analytical…

  7. Biodegradability study of high-erucic-acid-rapeseed-oil-based lubricant additives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, E.; Crawford, R.L.; Shanahan, A.

    1995-12-31

    A variety of high-erucic-acid-rapeseed (HEAR)-oil-based lubricants, lubricant additives, and greases were examined for biodegradability at the University of Idaho Center for Hazardous Waste Remediation Research. Two standard biodegradability tests were employed, a currently accepted US Environmental Protection Agency (EPA) protocol and the Sturm Test. As is normal for tests that employ variable inocula such as sewage as a source of microorganisms, these procedures yielded variable results from one repetition to another. However, a general trend of rapid and complete biodegradability of the HEAR-oil-based materials was observed.

  8. Definition and design of an experiment to test raster scanning with rotating unbalanced-mass devices on gimbaled payloads

    NASA Technical Reports Server (NTRS)

    Lightsey, W. D.; Alhorn, D. C.; Polites, M. E.

    1992-01-01

    An experiment designed to test the feasibility of using rotating unbalanced-mass (RUM) devices for line and raster scanning gimbaled payloads, while expending very little power is described. The experiment is configured for ground-based testing, but the scan concept is applicable to ground-based, balloon-borne, and space-based payloads, as well as free-flying spacecraft. The servos used in scanning are defined; the electronic hardware is specified; and a computer simulation model of the system is described. Simulation results are presented that predict system performance and verify the servo designs.

  9. Do the Guideline Violations Influence Test Difficulty of High-Stake Test?: An Investigation on University Entrance Examination in Turkey

    ERIC Educational Resources Information Center

    Atalmis, Erkan Hasan

    2016-01-01

    Multiple-choice (MC) items are commonly used in high-stake tests. Thus, each item of such tests should be meticulously constructed to increase the accuracy of decisions based on test results. Haladyna and his colleagues (2002) addressed the valid item-writing guidelines to construct high quality MC items in order to increase test reliability and…

  10. Wake Numerical Simulation Based on the Park-Gauss Model and Considering Atmospheric Stability

    NASA Astrophysics Data System (ADS)

    Yang, Xiangsheng; Zhao, Ning; Tian, Linlin; Zhu, Jun

    2016-06-01

    In this paper, a new Park-Gauss model based on the assumption of the Park model and the Eddy-viscosity model is investigated to conduct the wake numerical simulation for solving a single wind turbine problem. The initial wake radius has been modified to improve the model’s numerical accuracy. Then the impact of the atmospheric stability based on the Park-Gauss model has been studied in the wake region. By the comparisons and the analyses of the test results, it turns out that the new Park-Gauss model could achieve better effects of the wind velocity simulation in the wake region. The wind velocity in the wake region recovers quickly under the unstable atmospheric condition provided the wind velocity is closest to the test result, and recovers slowly under stable atmospheric condition in case of the wind velocity is lower than the test result. Meanwhile, the wind velocity recovery falls in between the unstable and stable neutral atmospheric conditions.

  11. Strict adherence to malaria rapid test results might lead to a neglect of other dangerous diseases: a cost benefit analysis from Burkina Faso.

    PubMed

    Bisoffi, Zeno; Sirima, Sodiomon B; Meheus, Filip; Lodesani, Claudia; Gobbi, Federico; Angheben, Andrea; Tinto, Halidou; Neya, Bouma; Van den Ende, Klara; Romeo, Annalisa; Van den Ende, Jef

    2011-08-04

    Malaria rapid diagnostic tests (RDTs) have generally been found reliable and cost-effective. In Burkina Faso, the adherence of prescribers to the negative test result was found to be poor. Moreover, the test accuracy for malaria-attributable fever (MAF) is not the same as for malaria infection. This paper aims at determining the costs and benefits of two competing strategies for the management of MAF: presumptive treatment for all or use of RDTs. A cost benefit analysis was carried out using a decision tree, based on data previously obtained, including a randomized controlled trial (RCT) recruiting 852 febrile patients during the dry season and 1,317 in the rainy season. Cost and benefit were calculated using both the real adherence found by the RCT and assuming an ideal adherence of 90% with the negative result. The main parameters were submitted to sensitivity analysis. At real adherence, the test-based strategy was dominated. Assuming ideal adherence, at the value of 525 € for a death averted, the total cost of managing 1,000 febrile children was 1,747 vs. 1,862 € in the dry season and 1,372 vs. 2,138 in the rainy season for the presumptive vs. the test-based strategy. For adults it was 2,728 vs. 1,983 and 2,604 vs. 2,225, respectively. At the subsidized policy adopted locally, assuming ideal adherence, the RDT would be the winning strategy for adults in both seasons and for children in the dry season.At sensitivity analysis, the factors most influencing the choice of the better strategy were the value assigned to a death averted and the proportion of potentially severe NMFI treated with antibiotics in patients with false positive RDT results. The test-based strategy appears advantageous for adults if a satisfactory adherence could be achieved. For children the presumptive strategy remains the best choice for a wide range of scenarios. For RDTs to be preferred, a positive result should not influence the decision to treat a potentially severe NMFI with antibiotics. In the rainy season the presumptive strategy always remains the better choice for children.

  12. The Marshall Space Flight Center KC-135 zero gravity test program for FY 1982

    NASA Technical Reports Server (NTRS)

    Shurney, R. E. (Editor)

    1983-01-01

    During FY-82, researchers and experimenters from Marshall Space Flight Center (MSFC) conducted 11 separate investigations during 26.3 hr of testing aboard the KC-135 zero-gravity aircraft, based at Ellington Air force Base, Texas. Although this represented fewer hours than initially projected, all experiment and test objectives were met or exceeded. This Technical Memorandum compiles all results achieved by MSFC users during FY-82, a year considered to be highly productive.

  13. The preparedness level of final year medical students for an adequate medical approach to emergency cases: computer-based medical education in emergency medicine

    PubMed Central

    2014-01-01

    Background We aimed to observe the preparedness level of final year medical students in approaching emergencies by computer-based simulation training and evaluate the efficacy of the program. Methods A computer-based prototype simulation program (Lsim), designed by researchers from the medical education and computer science departments, was used to present virtual cases for medical learning. Fifty-four final year medical students from Ondokuz Mayis University School of Medicine attended an education program on June 20, 2012 and were trained with Lsim. Volunteer attendants completed a pre-test and post-test exam at the beginning and end of the course, respectively, on the same day. Results Twenty-nine of the 54 students who attended the course accepted to take the pre-test and post-test exams; 58.6% (n = 17) were female. In 10 emergency medical cases, an average of 3.9 correct medical approaches were performed in the pre-test and an average of 9.6 correct medical approaches were performed in the post-test (t = 17.18, P = 0.006). Conclusions This study’s results showed that the readiness level of students for an adequate medical approach to emergency cases was very low. Computer-based training could help in the adequate approach of students to various emergency cases. PMID:24386919

  14. The Development of MST Test Information for the Prediction of Test Performances

    ERIC Educational Resources Information Center

    Park, Ryoungsun; Kim, Jiseon; Chung, Hyewon; Dodd, Barbara G.

    2017-01-01

    The current study proposes novel methods to predict multistage testing (MST) performance without conducting simulations. This method, called MST test information, is based on analytic derivation of standard errors of ability estimates across theta levels. We compared standard errors derived analytically to the simulation results to demonstrate the…

  15. Greater Real-Life Diagnostic Efficacy of Allergen Molecule-Based Diagnosis for Prescription of Immunotherapy in an Area with Multiple Pollen Exposure

    PubMed Central

    Saltabayeva, Ulbosin; Garib, Victoria; Morenko, Marina; Rosenson, Rafail; Ispayeva, Zhanat; Gatauova, Madina; Zulus, Loreta; Karaulov, Alexander; Gastager, Felix; Valenta, Rudolf

    2017-01-01

    Background Allergen molecule-based diagnosis has been suggested to facilitate the identification of disease-causing allergen sources and the prescription of allergen-specific immunotherapy (AIT). The aim of the current study was to compare allergen molecule-based IgE serology with allergen extract-based skin testing for the identification of the disease-causing allergen sources. The study was conducted in an area where patients are exposed to pollen from multiple sources (trees, grasses, and weeds) at the same time to compare the diagnostic efficiency of the 2 forms of diagnosis. Methods Patients from Astana, Kazakhstan, who suffered from pollen-induced allergy (n = 95) were subjected to skin prick testing (SPT) with a local panel of tree pollen, grass pollen, and weed pollen allergen extracts and IgE antibodies specific for marker allergen molecules (nArt v 1, nArt v 3, rAmb a 1, rPhl p 1, rPhl p 5, rBet v 1) were measured by ImmunoCAP. Direct and indirect costs for diagnosis based on SPT and marker allergen-based IgE serology as well as direct costs for immunotherapy depending on SPT and serological test results were calculated. Results The costs for SPT-based diagnosis per patient were lower than the costs for allergen molecule-based IgE serology. However, allergen molecule-based serology was more precise in detecting the disease-causing allergen sources. A lower number of immunotherapy treatments (n = 119) was needed according to molecular diagnosis as compared to extract-based diagnosis (n = 275), which considerably reduced the total costs for diagnosis and for a 3-year treatment from EUR 1,112.30 to 521.77 per patient. Conclusions The results from this real-life study show that SPT is less expensive than allergen molecule-based diagnostic testing, but molecular diagnosis allowed more precise prescription of immunotherapy which substantially reduced treatment costs and combined costs for diagnosis and treatment. PMID:28654920

  16. Sensitivity and Specificity of Human Immunodeficiency Virus Rapid Serologic Assays and Testing Algorithms in an Antenatal Clinic in Abidjan, Ivory Coast

    PubMed Central

    Koblavi-Dème, Stéphania; Maurice, Chantal; Yavo, Daniel; Sibailly, Toussaint S.; N′guessan, Kabran; Kamelan-Tano, Yvonne; Wiktor, Stefan Z.; Roels, Thierry H.; Chorba, Terence; Nkengasong, John N.

    2001-01-01

    To evaluate serologic testing algorithms for human immunodeficiency virus (HIV) based on a combination of rapid assays among persons with HIV-1 (non-B subtypes) infection, HIV-2 infection, and HIV-1–HIV-2 dual infections in Abidjan, Ivory Coast, a total of 1,216 sera with known HIV serologic status were used to evaluate the sensitivity and specificity of four rapid assays: Determine HIV-1/2, Capillus HIV-1/HIV-2, HIV-SPOT, and Genie II HIV-1/HIV-2. Two serum panels obtained from patients recently infected with HIV-1 subtypes B and non-B were also included. Based on sensitivity and specificity, three of the four rapid assays were evaluated prospectively in parallel (serum samples tested by two simultaneous rapid assays) and serial (serum samples tested by two consecutive rapid assays) testing algorithms. All assays were 100% sensitive, and specificities ranged from 99.4 to 100%. In the prospective evaluation, both the parallel and serial algorithms were 100% sensitive and specific. Our results suggest that rapid assays have high sensitivity and specificity and, when used in parallel or serial testing algorithms, yield results similar to those of enzyme-linked immunosorbent assay-based testing strategies. HIV serodiagnosis based on rapid assays may be a valuable alternative in implementing HIV prevention and surveillance programs in areas where sophisticated laboratories are difficult to establish. PMID:11325995

  17. Acceleration-based methodology to assess the blast mitigation performance of explosive ordnance disposal helmets

    NASA Astrophysics Data System (ADS)

    Dionne, J. P.; Levine, J.; Makris, A.

    2018-01-01

    To design the next generation of blast mitigation helmets that offer increasing levels of protection against explosive devices, manufacturers must be able to rely on appropriate test methodologies and human surrogates that will differentiate the performance level of various helmet solutions and ensure user safety. Ideally, such test methodologies and associated injury thresholds should be based on widely accepted injury criteria relevant within the context of blast. Unfortunately, even though significant research has taken place over the last decade in the area of blast neurotrauma, there currently exists no agreement in terms of injury mechanisms for blast-induced traumatic brain injury. In absence of such widely accepted test methods and injury criteria, the current study presents a specific blast test methodology focusing on explosive ordnance disposal protective equipment, involving the readily available Hybrid III mannequin, initially developed for the automotive industry. The unlikely applicability of the associated brain injury criteria (based on both linear and rotational head acceleration) is discussed in the context of blast. Test results encompassing a large number of blast configurations and personal protective equipment are presented, emphasizing the possibility to develop useful correlations between blast parameters, such as the scaled distance, and mannequin engineering measurements (head acceleration). Suggestions are put forward for a practical standardized blast testing methodology taking into account limitations in the applicability of acceleration-based injury criteria as well as the inherent variability in blast testing results.

  18. Alternate Protocol for Detecting Biological Contamination on Sensitive Hardware

    NASA Technical Reports Server (NTRS)

    Berlin, David; Lalime, Erin; Carosso, Nancy

    2015-01-01

    The purpose of this project is to develop a sterile water based rapid bioburden test. Contamination engineers use two tests to assess the level of biological contamination on hardware: the rapid five minute bioburden test, which is a molecular screening for Adenosine triphosphate (ATP), a molecule found in all cells on the hardware, and a slower colony growth test, which is used to give a more accurate representation of the amount of microbes on the hardware. However, the rapid bioburden test has limited application because it leaves a residue that can be detrimental to sensitive hardware. This can cause project delays while waiting for the results from the three day colony growth test. We address this problem by adapting the commercial germicide based ATP system to a sterile water based system. The test works by reacting ATP with D-Luciferin and Luciferase protein to yield light. The light is then detected by a luminometer that outputs a Relative Light Unit (RLU) amount depending on how much ATP is present. To analyze the effectiveness of the new test, we developed a correlation between amounts of ATP and the RLU produced using the germicide based system. From these experiments, we've generated a consistent relationship between the two in the form of a power curve. From there, we developed a correlation curve between the amount of colonies and the RLU they produced. Initial tests of the new protocol have shown that the water based system isn't as sensitive as the germicide based test.

  19. Absorbable magnesium-based stent: physiological factors to consider for in vitro degradation assessments

    PubMed Central

    Wang, Juan; Smith, Christopher E.; Sankar, Jagannathan; Yun, Yeoheung; Huang, Nan

    2015-01-01

    Absorbable metals have been widely tested in various in vitro settings using cells to evaluate their possible suitability as an implant material. However, there exists a gap between in vivo and in vitro test results for absorbable materials. A lot of traditional in vitro assessments for permanent materials are no longer applicable to absorbable metallic implants. A key step is to identify and test the relevant microenvironment and parameters in test systems, which should be adapted according to the specific application. New test methods are necessary to reduce the difference between in vivo and in vitro test results and provide more accurate information to better understand absorbable metallic implants. In this investigative review, we strive to summarize the latest test methods for characterizing absorbable magnesium-based stent for bioabsorption/biodegradation behavior in the mimicking vascular environments. Also, this article comprehensively discusses the direction of test standardization for absorbable stents to paint a more accurate picture of the in vivo condition around implants to determine the most important parameters and their dynamic interactions. PMID:26816631

  20. The Psychology Experiment Building Language (PEBL) and PEBL Test Battery

    PubMed Central

    Mueller, Shane T.; Piper, Brian J.

    2014-01-01

    Background We briefly describe the Psychology Experiment Building Language (PEBL), an open source software system for designing and running psychological experiments. New Method We describe the PEBL test battery, a set of approximately 70 behavioral tests which can be freely used, shared, and modified. Included is a comprehensive set of past research upon which tests in the battery are based. Results We report the results of benchmark tests that establish the timing precision of PEBL. Comparison with Existing Method We consider alternatives to the PEBL system and battery tests. Conclusions We conclude with a discussion of the ethical factors involved in the open source testing movement. PMID:24269254

  1. Cell module and fuel conditioner development

    NASA Technical Reports Server (NTRS)

    Hoover, D. Q., Jr.

    1981-01-01

    The test results of and post test analysis of Stack 559 are reported. The design features and construction status of Stacks 560, 561, 562 and 563 are described. The measurements of cell materials compressibility are rationalized and summarized and an explanation of their uses is given. Preliminary results of a manifold material/coating survey are given. The results of shift converter catalyst performance tests and reforming catalyst aging tests are reported. State points for full load and part load operation of the fuel conditioning subsystem tabulated. Work on the data base for the fuel conditioner ancillary subsystems is summarized.

  2. Alternative Bio-Derived JP-8 Class Fuel and JP-8 Fuel: Flame Tube Combustor Test Results Compared using a GE TAPS Injector Configuration

    NASA Technical Reports Server (NTRS)

    Hicks, Yolanda R.; Anderson, Robert; Tedder, Sarah

    2016-01-01

    This paper presents results from tests in a NASA Glenn Research Center (GRC) flame tube facility, where a bio-derived alternate fuel was compared with JP-8 for emissions and general combustion performance. A research version of General Electric Aviation (GE) TAPS injector was used for the tests. Results include 2D, planar laser-based imaging as well as basic flow visualization of the flame. Four conditions were selected that simulate various engine power conditions relevant to NASA Fundamental Aeronautics Supersonics and Environmentally Responsible Aviation Projects were tested.

  3. Testing Causal Impacts of a School-Based SEL Intervention Using Instrumental Variable Techniques

    ERIC Educational Resources Information Center

    Torrente, Catalina; Nathanson, Lori; Rivers, Susan; Brackett, Marc

    2015-01-01

    Children's social-emotional skills, such as conflict resolution and emotion regulation, have been linked to a number of highly regarded academic and social outcomes. The current study presents preliminary results from a causal test of the theory of change of RULER, a universal school-based approach to social and emotional learning (SEL).…

  4. Predicting Performance on State Achievement Tests Using Curriculum-Based Measurement in Reading: A Multilevel Meta-Analysis

    ERIC Educational Resources Information Center

    Yeo, Seungsoo

    2010-01-01

    The purpose of this synthesis was to examine the relationship between Curriculum-Based Measurement (CBM) and statewide achievement tests in reading. A multilevel meta-analysis was used to calculate the correlation coefficient of the population for 27 studies that met the inclusion criteria. Results showed an overall large correlation coefficient…

  5. A shift from significance test to hypothesis test through power analysis in medical research.

    PubMed

    Singh, G

    2006-01-01

    Medical research literature until recently, exhibited substantial dominance of the Fisher's significance test approach of statistical inference concentrating more on probability of type I error over Neyman-Pearson's hypothesis test considering both probability of type I and II error. Fisher's approach dichotomises results into significant or not significant results with a P value. The Neyman-Pearson's approach talks of acceptance or rejection of null hypothesis. Based on the same theory these two approaches deal with same objective and conclude in their own way. The advancement in computing techniques and availability of statistical software have resulted in increasing application of power calculations in medical research and thereby reporting the result of significance tests in the light of power of the test also. Significance test approach, when it incorporates power analysis contains the essence of hypothesis test approach. It may be safely argued that rising application of power analysis in medical research may have initiated a shift from Fisher's significance test to Neyman-Pearson's hypothesis test procedure.

  6. LCR testing for gonorrhoea and chlamydia in population surveys and other screenings of low prevalence populations: coping with decreased positive predictive value.

    PubMed

    Zenilman, J M; Miller, W C; Gaydos, C; Rogers, S M; Turner, C F

    2003-04-01

    Nucleic acid amplification tests have facilitated field based STD studies and increased screening activities. However, even with highly specific tests, the positive predictive value (PPV) of such tests may be lower than desirable in low prevalence populations. We estimated PPVs for a single LCR test in a population survey in which positive specimens were retested. The Baltimore STD and Behavior Survey (BSBS) was a population based behavioural survey of adults which included collecting urine specimens to assess the prevalence of gonorrhoea and chlamydial infection. Gonorrhoea and chlamydial infection were diagnosed by ligase chain reaction (LCR). Nearly all positive results were retested by LCR. Because of cost considerations, negative results were not confirmed. Predicted curves for the PPV were calculated for a single testing assuming an LCR test sensitivity of 95%, and test specificities in the range 95.0%-99.9%, for disease prevalences between 1% and 10%. Positive specimens were retested to derive empirical estimates of the PPV of a positive result on a single LCR test. 579 participants age 18-35 provided urine specimens. 20 (3.5%) subjects initially tested positive for chlamydial infection, and 39 (6.7%) tested positive for gonococcal infection. If positive results on the repeat LCR are taken as confirmation of a "true" infection, the observed PPV for the first LCR testing was 89.5% for chlamydial infection and 83.3% for gonorrhoea. This is within the range of theoretical PPVs calculated from the assumed sensitivities and specificities of the LCR assays. Empirical performance of a single LCR testing approximated the theoretically predicted PPV in this field study. This result demonstrates the need to take account of the lower PPVs obtained when such tests are used in field studies or clinical screening of low prevalence populations. Repeat testing of specimens, preferably with a different assay (for example, polymerase chain reaction), and disclosure of the non-trivial potential for false positive test results would seem appropriate in all such studies.

  7. Trends in Correlation-Based Pattern Recognition and Tracking in Forward-Looking Infrared Imagery

    PubMed Central

    Alam, Mohammad S.; Bhuiyan, Sharif M. A.

    2014-01-01

    In this paper, we review the recent trends and advancements on correlation-based pattern recognition and tracking in forward-looking infrared (FLIR) imagery. In particular, we discuss matched filter-based correlation techniques for target detection and tracking which are widely used for various real time applications. We analyze and present test results involving recently reported matched filters such as the maximum average correlation height (MACH) filter and its variants, and distance classifier correlation filter (DCCF) and its variants. Test results are presented for both single/multiple target detection and tracking using various real-life FLIR image sequences. PMID:25061840

  8. Highly-flexible fibre battery incorporating polypyrrole cathode and carbon nanotubes anode

    NASA Astrophysics Data System (ADS)

    Wang, J.; Wang, C. Y.; Too, C. O.; Wallace, G. G.

    The development of highly-flexible fibre batteries based on a conducting polymer and single-wall carbon nanotubes (SWNTs) is described. Initially, polypyrrole-hexafluorophosphate (PPy/PF 6) and SWNTs are tested in lithium cells to ascertain their performance. Based on the results, fibre batteries consisting of a PPy/PF 6 cathode and an anode based on SWNTs are fabricated and tested in both a "flooded cell" and 'dry cell', arrangement.

  9. A Novel Quantum Dots-Based Point of Care Test for Syphilis

    NASA Astrophysics Data System (ADS)

    Yang, Hao; Li, Ding; He, Rong; Guo, Qin; Wang, Kan; Zhang, Xueqing; Huang, Peng; Cui, Daxiang

    2010-05-01

    One-step lateral flow test is recommended as the first line screening of syphilis for primary healthcare settings in developing countries. However, it generally shows low sensitivity. We describe here the development of a novel fluorescent POC (Point Of Care) test method to be used for screening for syphilis. The method was designed to combine the rapidness of lateral flow test and sensitiveness of fluorescent method. 50 syphilis-positive specimens and 50 healthy specimens conformed by Treponema pallidum particle agglutination (TPPA) were tested with Quantum Dot-labeled and colloidal gold-labeled lateral flow test strips, respectively. The results showed that both sensitivity and specificity of the quantum dots-based method reached up to 100% (95% confidence interval [CI], 91-100%), while those of the colloidal gold-based method were 82% (95% CI, 68-91%) and 100% (95% CI, 91-100%), respectively. In addition, the naked-eye detection limit of quantum dot-based method could achieve 2 ng/ml of anti-TP47 polyclonal antibodies purified by affinity chromatography with TP47 antigen, which was tenfold higher than that of colloidal gold-based method. In conclusion, the quantum dots were found to be suitable for labels of lateral flow test strip. Its ease of use, sensitiveness and low cost make it well-suited for population-based on-the-site syphilis screening.

  10. Introduction of a method for presenting health-based impacts of the emission from products, based on emission measurements of materials used in manufacturing of the products

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jørgensen, Rikke Bramming, E-mail: rikke.jorgensen@iot.ntnu.no

    A method for presenting the health impact of emissions from furniture is introduced, which could be used in the context of environmental product declarations. The health impact is described by the negative indoor air quality potential, the carcinogenic potential, the mutagenic and reprotoxic potential, the allergenic potential, and the toxicological potential. An experimental study of emissions from four pieces of furniture is performed by testing both the materials used for production of the furniture and the complete piece of furniture, in order to compare the results gained by adding emissions of material with results gained from testing the finished piecemore » of furniture. Calculating the emission from a product based on the emission from materials used in the manufacture of the product is a new idea. The relation between calculated results and measured results from the same products differ between the four pieces of furniture tested. Large differences between measured and calculated values are seen for leather products. More knowledge is needed to understand why these differences arise. Testing materials allows us to compare different suppliers of the same material. Four different foams and three different timber materials are tested, and the results vary between materials of the same type. If the manufacturer possesses this type of knowledge of the materials from the subcontractors it could be used as a selection criterion according to production of low emission products. -- Highlights: • A method for presenting health impact of emissions is introduced. • An experimental study of emissions from four pieces of furniture is performed. • Health impact is calculated based on sum of contribution from the materials used. • Calculated health impact is compared to health impact of the manufactured product. • The results show that health impact could be useful in product development and for presentation in EPDs.« less

  11. Validation of NHB 8060.1C, Test 18 Arc Tracking, September 30, 1991

    NASA Technical Reports Server (NTRS)

    Linley, Larry

    2005-01-01

    A test project was conducted to validate Test 18 of NASA Handbook (NHB) 8060.1C and, if necessary, identify and recommend improvements in the procedures or criteria of the test. The NHB 8060.1C, Test 18 test system was modified to produce better discrimination of test results. Changes, and their effects on test results, in the graphite immersion-depth, test timing sequence, and atmospheric conditions were investigated for the wire-insulation constructions tested. Based on the test results, the graphite immersion-depths (between 0.8 mm and 1.6 mm), the timing sequence, and the change in the test conditions from ambient to three environments common in manned spaceflight did not significantly affect test results. The criteria used in Test 18 of NHB 8060.1C was found to be appropriate for qualifying arc-tracking and arc-propagation characteristics of wire-insulation materials, Using the Test 18 criteria, Kapton and ETFE were considered inappropriate for use, while PTFE was considered appropriate. Recommendations from this test project for Test 18 of NHB 8060.1C include changing the experimental setup and configurational tests and performing qualification testing in air rather than in the three environments common in manned spaceflight.

  12. A hybrid Jaya algorithm for reliability-redundancy allocation problems

    NASA Astrophysics Data System (ADS)

    Ghavidel, Sahand; Azizivahed, Ali; Li, Li

    2018-04-01

    This article proposes an efficient improved hybrid Jaya algorithm based on time-varying acceleration coefficients (TVACs) and the learning phase introduced in teaching-learning-based optimization (TLBO), named the LJaya-TVAC algorithm, for solving various types of nonlinear mixed-integer reliability-redundancy allocation problems (RRAPs) and standard real-parameter test functions. RRAPs include series, series-parallel, complex (bridge) and overspeed protection systems. The search power of the proposed LJaya-TVAC algorithm for finding the optimal solutions is first tested on the standard real-parameter unimodal and multi-modal functions with dimensions of 30-100, and then tested on various types of nonlinear mixed-integer RRAPs. The results are compared with the original Jaya algorithm and the best results reported in the recent literature. The optimal results obtained with the proposed LJaya-TVAC algorithm provide evidence for its better and acceptable optimization performance compared to the original Jaya algorithm and other reported optimal results.

  13. The cost-effectiveness of rapid HIV testing in substance abuse treatment: results of a randomized trial.

    PubMed

    Schackman, Bruce R; Metsch, Lisa R; Colfax, Grant N; Leff, Jared A; Wong, Angela; Scott, Callie A; Feaster, Daniel J; Gooden, Lauren; Matheson, Tim; Haynes, Louise F; Paltiel, A David; Walensky, Rochelle P

    2013-02-01

    The President's National HIV/AIDS Strategy calls for coupling HIV screening and prevention services with substance abuse treatment programs. Fewer than half of US community-based substance abuse treatment programs make HIV testing available on-site or through referral. We measured the cost-effectiveness of three HIV testing strategies evaluated in a randomized trial conducted in 12 community-based substance abuse treatment programs in 2009: off-site testing referral, on-site rapid testing with information only, on-site rapid testing with risk-reduction counseling. Data from the trial included patient demographics, prior testing history, test acceptance and receipt of results, undiagnosed HIV prevalence (0.4%) and program costs. The Cost-Effectiveness of Preventing AIDS Complications (CEPAC) computer simulation model was used to project life expectancy, lifetime costs, and quality-adjusted life years (QALYs) for HIV-infected individuals. Incremental cost-effectiveness ratios (2009 US $/QALY) were calculated after adding costs of testing HIV-uninfected individuals; costs and QALYs were discounted at 3% annually. Referral for off-site testing is less efficient (dominated) compared to offering on-site testing with information only. The cost-effectiveness ratio for on-site testing with information is $60,300/QALY in the base case, or $76,300/QALY with 0.1% undiagnosed HIV prevalence. HIV risk-reduction counseling costs $36 per person more without additional benefit. A strategy of on-site rapid HIV testing offer with information only in substance abuse treatment programs increases life expectancy at a cost-effectiveness ratio <$100,000/QALY. Policymakers and substance abuse treatment leaders should seek funding to implement on-site rapid HIV testing in substance abuse treatment programs for those not recently tested. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  14. Two-step rating-based 'double-faced applicability' test for sensory analysis of spread products as an alternative to descriptive analysis with trained panel.

    PubMed

    Kim, In-Ah; den-Hollander, Elyn; Lee, Hye-Seong

    2018-03-01

    Descriptive analysis with a trained sensory panel has thus far been the most well defined methodology to characterize various products. However, in practical terms, intensive training in descriptive analysis has been recognized as a serious defect. To overcome this limitation, various novel rapid sensory profiling methodologies have been suggested in the literature. Among these, attribute-based methodologies such as check-all-that-apply (CATA) questions showed results comparable to those of conventional sensory descriptive analysis. Kim, Hopkinson, van Hout, and Lee (2017a, 2017b) have proposed a novel attribute-based methodology termed the two-step rating-based 'double-faced applicability' test with a novel output measure of applicability magnitude (d' A ) for measuring consumers' product usage experience throughout various product usage stages. In this paper, the potential of the two-step rating-based 'double-faced applicability' test with d' A was investigated as an alternative to conventional sensory descriptive analysis in terms of sensory characterization and product discrimination. Twelve commercial spread products were evaluated using both conventional sensory descriptive analysis with a trained sensory panel and two-step rating-based 'double-faced applicability' test with an untrained sensory panel. The results demonstrated that the 'double-faced applicability' test can be used to provide a direct measure of the applicability magnitude of sensory attributes of the samples tested in terms of d' A for sensory characterization of individual samples and multiple sample comparisons. This suggests that when the appropriate list of attributes to be used in the questionnaire is already available, the two-step rating-based 'double-faced applicability' test with d' A can be used as a more efficient alternative to conventional descriptive analysis, without requiring any intensive training process. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Combination of DNA-based and conventional methods to detect human leukocyte antigen polymorphism and its use for paternity testing.

    PubMed

    Kereszturya, László; Rajczya, Katalin; Lászikb, András; Gyódia, Eva; Pénzes, Mária; Falus, András; Petrányia, Gyõzõ G

    2002-03-01

    In cases of disputed paternity, the scientific goal is to promote either the exclusion of a falsely accused man or the affiliation of the alleged father. Until now, in addition to anthropologic characteristics, the determination of genetic markers included human leukocyte antigen gene variants; erythrocyte antigens and serum proteins were used for that reason. Recombinant DNA techniques provided a new set of highly variable genetic markers based on DNA nucleotide sequence polymorphism. From the practical standpoint, the application of these techniques to paternity testing provides greater versatility than do conventional genetic marker systems. The use of methods to detect the polymorphism of human leukocyte antigen loci significantly increases the chance of validation of ambiguous results in paternity testing. The outcome of 2384 paternity cases investigated by serologic and/or DNA-based human leukocyte antigen typing was statistically analyzed. Different cases solved by DNA typing are presented involving cases with one or two accused men, exclusions and nonexclusions, and tests of the paternity of a deceased man. The results provide evidence for the advantage of the combined application of various techniques in forensic diagnostics and emphasizes the outstanding possibilities of DNA-based assays. Representative examples demonstrate the strength of combined techniques in paternity testing.

  16. Differential effects of scopolamine and amphetamine on microcomputer-based performance tests

    NASA Technical Reports Server (NTRS)

    Kennedy, Robert S.; Odenheimer, Robert C.; Baltzley, Dennis R.; Dunlap, William P.; Wood, Charles D.

    1990-01-01

    The effects of four weekly treatments with scopolamine (1.0 mg) and d-amphetamine (10 mg), separately or in combination, on human performance were investigated in 16 subjects undergoing nine performance tests from a menu of microcomputer-based tests administered after the treatment. It was d-amphetamine treatment that enhanced the results of motor and perceptual speed tests, while scopolamine had no effect on these tests. Two of the five cognitive tests showed reductions with scopolamine. The effects of scopolamine in this and other studies are considered in terms of a model which implies that the magnitude of the performance deficit depends on the performance type and the dosage level of the drug.

  17. A System for the Automatic Assembly of Test Questions Using a No-SQL Database

    ERIC Educational Resources Information Center

    Shin, Sanggyu; Hashimoto, Hiroshi

    2014-01-01

    We describe a system that automatically assembles test questions from a set of examples. Our system can create test questions appropriate for each user's level at low cost. In particular, when a user review their lesson, our system provides new test questions which are assembled based on their previous test results and past mistakes, rather than a…

  18. Language Testing: An Overview and Language Testing in Educational Institutions of Bangladesh

    ERIC Educational Resources Information Center

    Hossain, Md. Mahroof; Ahmed, Md. Kawser

    2015-01-01

    Test is procedures for measuring ability, knowledge or performance. Testing can be defined as a method of assessment and improvement of the students. Language testing in any point is an extremely multifarious task that ought to be based on method as well as exercise. The results of assessments are used for one or more purposes. So they have an…

  19. Attitude algorithm and initial alignment method for SINS applied in short-range aircraft

    NASA Astrophysics Data System (ADS)

    Zhang, Rong-Hui; He, Zhao-Cheng; You, Feng; Chen, Bo

    2017-07-01

    This paper presents an attitude solution algorithm based on the Micro-Electro-Mechanical System and quaternion method. We completed the numerical calculation and engineering practice by adopting fourth-order Runge-Kutta algorithm in the digital signal processor. The state space mathematical model of initial alignment in static base was established, and the initial alignment method based on Kalman filter was proposed. Based on the hardware in the loop simulation platform, the short-range flight simulation test and the actual flight test were carried out. The results show that the error of pitch, yaw and roll angle is fast convergent, and the fitting rate between flight simulation and flight test is more than 85%.

  20. [Usefulness of the initial medical examination on matters relating to persons suspected of driving under the influence of amphetamine and its analogs or delta9-tetrahydrocannabinol based on the materials the Department of Forensic Medicine, Pomeranian Medical University in Szczecin].

    PubMed

    Wolski, Stanisław; Lewandowska, Ewa; Kurzejamska-Parafiniuk, Małgorzata

    2013-01-01

    Polish law forbids persons to drive under the influence of intoxicating substances, and those after the use of substances producing effects similar to alcohol. Therefore, there is a need to give an opinion based on a blood test, to establish whether or not the person from whom the blood was taken was under the influence of an intoxicating substance or after use of the drug while driving. Some authors reported that the final opinion should take into account chemical and toxicology test results identifying the parent compound and/or the metabolite only, but also the sampling time of the material to be analyzed in relation to the driving time, the result of the medical examination conducted prior to the collection of material for analysis, and the results of screening tests executed at the scene. Circumstances relating to the event, the findings and observations of third parties, and the testimony of the suspect are also relevant. The aim of this study was to evaluate the results of the medical examination in the evaluation of cases concerning driving by persons who were potentially under the influence of amphetamine and its analogs, or delta9-tetrahydrocannabinol, (delta9-THC) and conformity assessment of these results with the results of blood tests. An additional aim was to determine the factors considered by doctors when making their evaluation of patient's condition. The study group consisted of 350 persons suspected of driving while under the influence of amphetamine and its analogs, and/or delta9-THC, from whom blood samples were taken to test amphetamine content or its analogues and/or delta9-tetrahydrocannabinol. Blood tests were carried out according to the existing procedure developed by the department. Blood samples were initially analyzed with immunochemical methods. Positive preliminary results were verified by gas chromatography-mass spectrometry. Statistical analysis was conducted with independent tests for multi-way tables, i.e. the Pearson chi2 test and the 2 x 2 tables Yates' correction was used for the low numbers. Comparison of mean concentrations of amphetamine and delta9-THC in the blood was performed using the U Mann-Whitney test. The analysis revealed a significant correlation between the symptoms and the results of the chemical-toxicological blood tests for mood only. There was no significant correlation between the results of toxicological and physical elements contained in the protocol of blood collection as the skin's appearance, speech, heart rate, pupil, pupil reaction to light, walking, lifting objects off the ground, the Romberg test, the finger-to-nose test and orientation in the space time environment. In the analysis of the relationship between the medical assessment and physical elements significant relationships with the assessment of mood, pupils, pupil reaction to light and gait were found. A significant correlation between the prevalence of symptoms in terms of any/none and medical evaluation was found. 1. Preliminary medical examination based on the blood sampling protocol has no practical importance for determining whether a person is tested under the influence of amphetamines or its analogues and/or delta9-THC. 2. The confirmation of the state "under the influence of narcotics or psychotropics" should only be based on blood test results. 3. Doctors, when completing the blood collection report, are often guided by factors other than the test results when making assessment. 4. The low utility of the medical examination is affected by lack of standardization of test items. Doctors often find symptoms in a subjective manner.

  1. Evaluation of biological methods for a future methodological implementation of the Hazard criterion H14 'ecotoxic' in the European waste list (2000/532/EC).

    PubMed

    Moser, Heidrun; Roembke, Joerg; Donnevert, Gerhild; Becker, Roland

    2011-02-01

    The ecotoxicological characterization of waste is part of its assessment as hazardous or non-hazardous according to the European Waste List. For this classification 15 hazard criteria are derived from the Council Directive 91/689/EEC on hazardous waste. Some of the hazard criteria are based on the content of dangerous substances. The criterion H14 'ecotoxic' lacks of an assessment and testing strategy and no specific threshold values have been defined so far. Based on the recommendations of CEN guideline 14735 (2005), an international round robin test (ring test) was organized by the German Federal Environment Agency in order to define suitable test methods for the biological assessment of waste and waste eluates. A basic test battery, consisting of three aquatic and three terrestrial tests, was compiled. In addition, data were submitted for ten additional tests (five aquatic (including a genotoxicity test) and five terrestrial ones). The tests were performed with three representative waste types: an ash from an incineration plant, a soil containing high concentrations of organic contaminants (polycyclic aromatic hydrocarbons) and a preserved wood waste. The results of this ring test confirm that a combination of a battery of biological tests and chemical residual analysis is needed for an ecotoxicological characterization of wastes. With small modifications the basic test battery is considered to be well suitable for the hazard and risk assessment of wastes and waste eluates. All results and documents are accessible via a web-based data bank application.

  2. Black-Box System Testing of Real-Time Embedded Systems Using Random and Search-Based Testing

    NASA Astrophysics Data System (ADS)

    Arcuri, Andrea; Iqbal, Muhammad Zohaib; Briand, Lionel

    Testing real-time embedded systems (RTES) is in many ways challenging. Thousands of test cases can be potentially executed on an industrial RTES. Given the magnitude of testing at the system level, only a fully automated approach can really scale up to test industrial RTES. In this paper we take a black-box approach and model the RTES environment using the UML/MARTE international standard. Our main motivation is to provide a more practical approach to the model-based testing of RTES by allowing system testers, who are often not familiar with the system design but know the application domain well-enough, to model the environment to enable test automation. Environment models can support the automation of three tasks: the code generation of an environment simulator, the selection of test cases, and the evaluation of their expected results (oracles). In this paper, we focus on the second task (test case selection) and investigate three test automation strategies using inputs from UML/MARTE environment models: Random Testing (baseline), Adaptive Random Testing, and Search-Based Testing (using Genetic Algorithms). Based on one industrial case study and three artificial systems, we show how, in general, no technique is better than the others. Which test selection technique to use is determined by the failure rate (testing stage) and the execution time of test cases. Finally, we propose a practical process to combine the use of all three test strategies.

  3. Immediate reactions to iodinated contrast media.

    PubMed

    Morales-Cabeza, Cristina; Roa-Medellín, Dasha; Torrado, Inés; De Barrio, Manuel; Fernández-Álvarez, Carmen; Montes-Aceñero, Juan Francisco; De La Riva, Inmaculada; Prieto-García, Alicia

    2017-12-01

    Immediate hypersensitivity reactions (IHRs) to iodinated contrast media (ICMs) remain a common clinical concern. Positive skin test and basophil activation test results suggest a specific IgE-mediated mechanism in some cases. Skin test and controlled challenge test (CCT) are useful to manage these patients. To study clinical and allergologic features of IHRs to ICMs in a Spanish tertiary hospital during a 7-year period. Demographic and clinical data concerning the reaction were recorded. Patients treated at the Allergy Department of Hospital General Universitario Gregorio Marañón, Madrid, Spain, underwent skin tests. In those with positive results, CCTs with an alternative skin-test-negative ICM was performed. Global reaction rate was calculated and compared for each ICM. A total of 342 reactions occurred in 329 patients. Cutaneous symptoms were the most common (87.7%). A total of 196 patients underwent an allergy workup, 15 (7.6%) of whom had positive skin test results. Reactions were more severe in patients with positive vs negative skin test results (grade 1, 46.7% vs 73.6%; grade 2, 33.3% vs 20.9%; grade 3, 20% vs 5.46%; P < .05). Three patients had cross-reactivity to 3 ICMs, all including ioversol and iomeprol. Six patients allergic to iopamidol tolerated ioversol and 1 tolerated iomeprol. Four patients allergic to ioversol and 1 allergic to iomeprol tolerated iopamidol. The global reaction rate was 0.2%, differing for each ICM (iopamidol, 0.14%; ioversol, 0.2%; and iomeprol, 0.4%; P < .001). Positive skin test results were found in a low percentage of patients in whom skin test-based CCT identified an alternative non-cross-reactive ICM. Low-grade cross-reactivity was found, especially between iopamidol and ioversol. Reactions were more severe in patients with positive skin test results. The reaction rate was greater for iomeprol compared with iopamidol (reaction rate, 2.8%) and ioversol (reaction rate, 2%). This study identified a possible underlying specific IgE-mediated mechanism by positive skin test result in a low percentage of patients with IHRs to ICMs. In these patients, the CCT based on skin test results was useful for identifying an alternative non-cross-reactive ICM. More studies are needed to investigate the underlying mechanism in patients with IHRs and negative skin test results. Copyright © 2017 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  4. An Improved SoC Test Scheduling Method Based on Simulated Annealing Algorithm

    NASA Astrophysics Data System (ADS)

    Zheng, Jingjing; Shen, Zhihang; Gao, Huaien; Chen, Bianna; Zheng, Weida; Xiong, Xiaoming

    2017-02-01

    In this paper, we propose an improved SoC test scheduling method based on simulated annealing algorithm (SA). It is our first to disorganize IP core assignment for each TAM to produce a new solution for SA, allocate TAM width for each TAM using greedy algorithm and calculate corresponding testing time. And accepting the core assignment according to the principle of simulated annealing algorithm and finally attain the optimum solution. Simultaneously, we run the test scheduling experiment with the international reference circuits provided by International Test Conference 2002(ITC’02) and the result shows that our algorithm is superior to the conventional integer linear programming algorithm (ILP), simulated annealing algorithm (SA) and genetic algorithm(GA). When TAM width reaches to 48,56 and 64, the testing time based on our algorithm is lesser than the classic methods and the optimization rates are 30.74%, 3.32%, 16.13% respectively. Moreover, the testing time based on our algorithm is very close to that of improved genetic algorithm (IGA), which is state-of-the-art at present.

  5. Bridging barriers to clinic-based HIV testing with new technology: translating self-implemented testing for African American youth.

    PubMed

    Catania, J A; Dolcini, M M; Harper, G W; Dowhower, D P; Dolcini-Catania, L G; Towner, S L; Timmons, A; Motley, D N; Tyler, D H

    2015-12-01

    Numerous barriers to clinic-based HIV testing exist (e.g., stigmatization) for African American youth. These barriers may be addressed by new technology, specifically HIV self-implemented testing (SIT). We conducted a series of formative phase 3 translation studies (49 face-to-face interviews, 9 focus groups, 1 advisory panel review) among low-income African American youth (15-19 years) and providers of adolescent services in two US cities to identify potential translation difficulties of the OraQuick SIT. Based on content analysis, we found that providers and African American youth viewed SITs positively compared to clinic-based testing. Data suggest that SITs may reduce social stigma and privacy concerns and increase convenience and normalization of HIV testing. Challenges with SIT implementation include difficulties accessing confirmatory testing, coping with adverse outcomes, and instructional materials that may be inappropriate for low socioeconomic status (SES) persons. Study results underscore the need for translation studies to identify specific comprehension and implementation problems African American youth may have with oral SITs.

  6. Cost effectiveness of population based BRCA1 founder mutation testing in Sephardi Jewish women.

    PubMed

    Patel, Shreeya; Legood, Rosa; Evans, D Gareth; Turnbull, Clare; Antoniou, Antonis C; Menon, Usha; Jacobs, Ian; Manchanda, Ranjit

    2018-04-01

    Population-based BRCA1/BRCA2 founder-mutation testing has been demonstrated as cost effective compared with family history based testing in Ashkenazi Jewish women. However, only 1 of the 3 Ashkenazi Jewish BRCA1/BRCA2 founder mutations (185delAG[c.68_69delAG]), 5382insC[c.5266dupC]), and 6174delT[c.5946delT]) is found in the Sephardi Jewish population (185delAG[c.68_69delAG]), and the overall prevalence of BRCA mutations in the Sephardi Jewish population is accordingly lower (0.7% compared with 2.5% in the Ashkenazi Jewish population). Cost-effectiveness analyses of BRCA testing have not previously been performed at these lower BRCA prevalence levels seen in the Sephardi Jewish population. Here we present a cost-effectiveness analysis for UK and US populations comparing population testing with clinical criteria/family history-based testing in Sephardi Jewish women. A Markov model was built comparing the lifetime costs and effects of population-based BRCA1 testing, with testing using family history-based clinical criteria in Sephardi Jewish women aged ≥30 years. BRCA1 carriers identified were offered magnetic resonance imaging/mammograms and risk-reducing surgery. Costs are reported at 2015 prices. Outcomes include breast cancer, ovarian cancer, and excess deaths from heart disease. All costs and outcomes are discounted at 3.5%. The time horizon is lifetime, and perspective is payer. The incremental cost-effectiveness ratio per quality-adjusted life-year was calculated. Parameter uncertainty was evaluated through 1-way and probabilistic sensitivity analysis. Population testing resulted in gain in life expectancy of 12 months (quality-adjusted life-year = 1.00). The baseline discounted incremental cost-effectiveness ratio for UK population-based testing was £67.04/quality-adjusted life-year and for US population was $308.42/quality-adjusted life-year. Results were robust in the 1-way sensitivity analysis. The probabilistic sensitivity analysis showed 100% of simulations were cost effective at £20,000/quality-adjusted life-year UK and the $100,000/quality-adjusted life-year US willingness-to-pay thresholds. Scenario analysis showed that population testing remains cost effective in UK and US populations, even if premenopausal oophorectomy does not reduce breast cancer risk or if hormone replacement therapy compliance is nil. Population-based BRCA1 testing is highly cost effective compared with clinical criteria-driven approach in Sephardi Jewish women. This supports changing the paradigm to population-based BRCA testing in the Jewish population, regardless of Ashkenazi/Sephardi ancestry. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Cognitive tests predict real-world errors: the relationship between drug name confusion rates in laboratory-based memory and perception tests and corresponding error rates in large pharmacy chains

    PubMed Central

    Schroeder, Scott R; Salomon, Meghan M; Galanter, William L; Schiff, Gordon D; Vaida, Allen J; Gaunt, Michael J; Bryson, Michelle L; Rash, Christine; Falck, Suzanne; Lambert, Bruce L

    2017-01-01

    Background Drug name confusion is a common type of medication error and a persistent threat to patient safety. In the USA, roughly one per thousand prescriptions results in the wrong drug being filled, and most of these errors involve drug names that look or sound alike. Prior to approval, drug names undergo a variety of tests to assess their potential for confusability, but none of these preapproval tests has been shown to predict real-world error rates. Objectives We conducted a study to assess the association between error rates in laboratory-based tests of drug name memory and perception and real-world drug name confusion error rates. Methods Eighty participants, comprising doctors, nurses, pharmacists, technicians and lay people, completed a battery of laboratory tests assessing visual perception, auditory perception and short-term memory of look-alike and sound-alike drug name pairs (eg, hydroxyzine/hydralazine). Results Laboratory test error rates (and other metrics) significantly predicted real-world error rates obtained from a large, outpatient pharmacy chain, with the best-fitting model accounting for 37% of the variance in real-world error rates. Cross-validation analyses confirmed these results, showing that the laboratory tests also predicted errors from a second pharmacy chain, with 45% of the variance being explained by the laboratory test data. Conclusions Across two distinct pharmacy chains, there is a strong and significant association between drug name confusion error rates observed in the real world and those observed in laboratory-based tests of memory and perception. Regulators and drug companies seeking a validated preapproval method for identifying confusing drug names ought to consider using these simple tests. By using a standard battery of memory and perception tests, it should be possible to reduce the number of confusing look-alike and sound-alike drug name pairs that reach the market, which will help protect patients from potentially harmful medication errors. PMID:27193033

  8. Detailed modeling of the train-to-train impact test : rail passenger equipment impact tests

    DOT National Transportation Integrated Search

    2007-07-01

    This report describes the results of a finite element-based analysis of the train-to-train impact test conducted at the Federal Railroad Administrations Transportation Technology Center in Pueblo, CO, on January 31, 2002. The ABAQUS/Explicit dynam...

  9. 40 CFR 80.47 - Performance-based Analytical Test Method Approach.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... chemistry and statistics, or at least a bachelor's degree in chemical engineering, from an accredited... be compensated for any known chemical interferences using good laboratory practices. (3) The test... section, individual test results shall be compensated for any known chemical interferences using good...

  10. Integrated vehicle-based safety systems heavy-truck on-road test report

    DOT National Transportation Integrated Search

    2008-08-01

    This report presents results from a series of on-road verification tests performed to determine the readiness of a prototype : integrated warning system to advance to field testing, as well as to identify areas of system performance that should be im...

  11. Integrated vehicle-based safety systems light-vehicle on-road test report

    DOT National Transportation Integrated Search

    2008-08-01

    This report presents results from a series of on-road verification tests performed to determine the readiness of a prototype : integrated warning system to advance to field testing, as well as to identify areas of system performance that should be im...

  12. Study and Validation of Eavesdropping Scenarios over a Visible Light Communication Channel

    PubMed Central

    Perez-Jimenez, Rafael

    2017-01-01

    The security and privacy provided by Visible Light Communication (VLC) technologies is an area that has been slightly addressed due to the misconception that, since light does not go through solid objects like walls, VLC-based communications cannot be eavesdropped on by outside observers. As an upcoming technology, VLC is expected to be used in multiple environments were, due to radio frequency RF overuse or limitations, RF solutions cannot or should not be employed. In this work, we study the eavesdropping characteristics of a VLC-based communication. To evaluate these concerns, a two-step process was followed. First, several simulations of a standardly used scenario were run. Later on, experimental tests were performed. Following those tests, the results of the simulations and the experimental tests were analyzed. The results of these simulations and tests seemed to indicate that VLC channels can be eavesdropped on without considerable difficulties. Furthermore, the results showed that sniffing attacks could be performed from areas outside the expected coverage of the VLC infrastructure. Finally, the use of the simulation such as the one implemented in this work to recognize places from which sniffing is possible helps determine the risk for eavesdropping that our VLC-based network has. PMID:29160800

  13. Study and Validation of Eavesdropping Scenarios over a Visible Light Communication Channel.

    PubMed

    Marin-Garcia, Ignacio; Guerra, Victor; Perez-Jimenez, Rafael

    2017-11-21

    The security and privacy provided by Visible Light Communication (VLC) technologies is an area that has been slightly addressed due to the misconception that, since light does not go through solid objects like walls, VLC-based communications cannot be eavesdropped on by outside observers. As an upcoming technology, VLC is expected to be used in multiple environments were, due to radio frequency RF overuse or limitations, RF solutions cannot or should not be employed. In this work, we study the eavesdropping characteristics of a VLC-based communication. To evaluate these concerns, a two-step process was followed. First, several simulations of a standardly used scenario were run. Later on, experimental tests were performed. Following those tests, the results of the simulations and the experimental tests were analyzed. The results of these simulations and tests seemed to indicate that VLC channels can be eavesdropped on without considerable difficulties. Furthermore, the results showed that sniffing attacks could be performed from areas outside the expected coverage of the VLC infrastructure. Finally, the use of the simulation such as the one implemented in this work to recognize places from which sniffing is possible helps determine the risk for eavesdropping that our VLC-based network has.

  14. Patients' acceptance of Internet-based home asthma telemonitoring.

    PubMed

    Finkelstein, J; Hripcsak, G; Cabrera, M R

    1998-01-01

    We studied asthma patients from a low-income inner-city community without previous computer experience. The patients were given portable spirometers to perform spirometry tests and palmtop computers to enter symptoms in a diary, to exchange messages with physician and to review test results. The self-testing was performed at home on a daily basis. The results were transmitted to the hospital information system immediately after completion of each test. Physician could review results using an Internet Web browser from any location. A constantly active decision support server monitored all data traffic and dispatched alerts when certain clinical conditions were met. Seventeen patients, out of 19 invited, agreed to participate in the study and have been monitored for three weeks. They have been surveyed then using standardized questionnaire. Most of the patients (82.4%) characterized self-testing procedures as "not complicated at all." In 70.6% of cases self-testing did not interfere with usual activities, and 82.4% of patients felt the self-testing required a "very little" amount of their time. All patients stated that it is important for them to know that the results can be reviewed by professional staff in a timely manner. However, only 29.5% of patients reviewed their results at least once a week at home independently. The majority of the patients (94.1%) were strongly interested in using home asthma telemonitoring in the future. We concluded that Internet-based home asthma telemonitoring can be successfully implemented in the group of patients without previous computer background.

  15. Arcjet Testing of Micro-Meteoroid Impacted Thermal Protection Materials

    NASA Technical Reports Server (NTRS)

    Agrawal, Parul; Munk, Michelle M.; Glaab, Louis J.

    2013-01-01

    There are several harsh space environments that could affect thermal protection systems and in turn pose risks to the atmospheric entry vehicles. These environments include micrometeoroid impact, extreme cold temperatures, and ionizing radiation during deep space cruise, all followed by atmospheric entry heating. To mitigate these risks, different thermal protection material samples were subjected to multiple tests, including hyper velocity impact, cold soak, irradiation, and arcjet testing, at various NASA facilities that simulated these environments. The materials included a variety of honeycomb packed ablative materials as well as carbon-based non-ablative thermal protection systems. The present paper describes the results of the multiple test campaign with a focus on arcjet testing of thermal protection materials. The tests showed promising results for ablative materials. However, the carbon-based non-ablative system presented some concerns regarding the potential risks to an entry vehicle. This study provides valuable information regarding the capability of various thermal protection materials to withstand harsh space environments, which is critical to sample return and planetary entry missions.

  16. Verification tests of the US Electricar Corporation Lectric Leopard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dowgiallo, E.J. Jr.; Snellings, I.R.; Chapman, R.D.

    1982-04-01

    The Lectric Leopard, manufactured by US Electricar Corporation, was tested during the period 3 August 1981 to 25 September 1981. Part of the verification results are summarized below (complete tests results are contained in Section V): Acceleration: 0-50 km/h (31.1 mi/h) in 9.9 s. Range: SAE J227a cycle ''C'' on level (+-1-percent grade) terrain yielded 66.2 km (41.2 mi) and 120 cycles. Forward Speed Capability: Forward speed of 80 km/h (50 mi/h) was maintained for more than 5 min on the level (+-1-percent grade) portion of the MERADCOM Test Track. Gradeability at Speed: At 25 km/h (15.5 mi/h) the vehiclemore » can traverse a 15.5-percent grade based on calculations from acceleration tests. Gradeability Limit: Calculations based on drawbar-pull test indicate a 35.2-percent forward and a 36.4-percent gradeability for at least 20 s.« less

  17. Impact of Genetic Counseling and Connexin-26 and Connexin-30 Testing on Deaf Identity and Comprehension of Genetic Test Results in a Sample of Deaf Adults: A Prospective, Longitudinal Study

    PubMed Central

    Palmer, Christina G. S.; Boudreault, Patrick; Baldwin, Erin E.; Sinsheimer, Janet S.

    2014-01-01

    Using a prospective, longitudinal study design, this paper addresses the impact of genetic counseling and testing for deafness on deaf adults and the Deaf community. This study specifically evaluated the effect of genetic counseling and Connexin-26 and Connexin-30 genetic test results on participants' deaf identity and understanding of their genetic test results. Connexin-26 and Connexin-30 genetic testing was offered to participants in the context of linguistically and culturally appropriate genetic counseling. Questionnaire data collected from 209 deaf adults at four time points (baseline, immediately following pre-test genetic counseling, 1-month following genetic test result disclosure, and 6-months after result disclosure) were analyzed. Four deaf identity orientations (hearing, marginal, immersion, bicultural) were evaluated using subscales of the Deaf Identity Development Scale-Revised. We found evidence that participants understood their specific genetic test results following genetic counseling, but found no evidence of change in deaf identity based on genetic counseling or their genetic test results. This study demonstrated that culturally and linguistically appropriate genetic counseling can improve deaf clients' understanding of genetic test results, and the formation of deaf identity was not directly related to genetic counseling or Connexin-26 and Connexin-30 genetic test results. PMID:25375116

  18. Effect of aquatic versus land based exercise programs on physical performance in severely burned patients: a randomized controlled trial.

    PubMed

    Zoheiry, Ibrahim M; Ashem, Haidy N; Ahmed, Hamada Ahmed Hamada; Abbas, Rami

    2017-12-01

    [Purpose] To compare the effect of an aquatic-based versus a land-based exercise regimen on the physical performance of severely burned patients. [Subjects and Methods] Forty patients suffering from severe burn (total body surface area more than 30%) were recruited from several outpatient clinics in Greater Cairo. Their ages ranged between 20 to 40 years and were randomly assigned into two equal groups: group (A), which received an aquatic based exercise program, and group (B), which received a land-based exercise program. The exercise program, which took place in 12 consecutive weeks, consisted of flexibility, endurance, and lower and upper body training. Physical performance was assessed using 30 seconds chair stand test, stair climb test, 30 meter fast paced walk test, time up and go test, 6-minute walk test and a VO2max evaluation. [Results] Significantly increase in the 30 second chair stand, 6-minute walk, 30 meter fast paced walk, stair climb, and VO2 max tests and significantly decrease in the time up and go test in group A (aquatic based exercise) compared with group B (a land-based exercise) at the post treatment. [Conclusion] Twelve-week program of an aquatic program yields improvement in both physical performance and VO2 max in patients with severe burns.

  19. Effect of aquatic versus land based exercise programs on physical performance in severely burned patients: a randomized controlled trial

    PubMed Central

    Zoheiry, Ibrahim M.; Ashem, Haidy N.; Ahmed, Hamada Ahmed Hamada; Abbas, Rami

    2017-01-01

    [Purpose] To compare the effect of an aquatic-based versus a land-based exercise regimen on the physical performance of severely burned patients. [Subjects and Methods] Forty patients suffering from severe burn (total body surface area more than 30%) were recruited from several outpatient clinics in Greater Cairo. Their ages ranged between 20 to 40 years and were randomly assigned into two equal groups: group (A), which received an aquatic based exercise program, and group (B), which received a land-based exercise program. The exercise program, which took place in 12 consecutive weeks, consisted of flexibility, endurance, and lower and upper body training. Physical performance was assessed using 30 seconds chair stand test, stair climb test, 30 meter fast paced walk test, time up and go test, 6-minute walk test and a VO2max evaluation. [Results] Significantly increase in the 30 second chair stand, 6-minute walk, 30 meter fast paced walk, stair climb, and VO2 max tests and significantly decrease in the time up and go test in group A (aquatic based exercise) compared with group B (a land-based exercise) at the post treatment. [Conclusion] Twelve-week program of an aquatic program yields improvement in both physical performance and VO2 max in patients with severe burns. PMID:29643605

  20. Specific physiological and biomechanical performance in elite, sub-elite and in non-elite male team handball players.

    PubMed

    Wagner, Herbert; Fuchs, Philip X; von Duvillard, Serge P

    2018-01-01

    Team handball is a dynamic sport game that is played professionally in numerous countries. However, knowledge about training and competition is based mostly on practical experience due to limited scientific studies. Consequently, the aims of our study were to compare specific physiological and biomechanical performance in elite, sub-elite and in non-elite male team handball players. Thirty-six elite, sub-elite and non-elite male team handball players performed a game based performance test, upper-body and lower-body strength tests, 30-m sprint test, counter movement jump test and an incremental treadmill running test. Significant differences (P<0.05) were found for the peak oxygen uptake, heart rate, offense and defense time, jump height and ball velocity during the jump throw in the game based performance test, maximal oxygen uptake in the incremental treadmill running test as well as in maximal leg strength and leg explosive strength in the isometric strength test. Elite male players have an enhanced specific agility, a better throwing performance, a higher team handball specific oxygen uptake and higher leg strength compared to sub-elite and non-elite players. Based on these results we recommend that training in team handball should focus on game based training methods to improve performance in specific agility, endurance and technique.

  1. Illegal performance enhancing drugs and doping in sport: a picture-based brief implicit association test for measuring athletes' attitudes.

    PubMed

    Brand, Ralf; Heck, Philipp; Ziegler, Matthias

    2014-01-30

    Doping attitude is a key variable in predicting athletes' intention to use forbidden performance enhancing drugs. Indirect reaction-time based attitude tests, such as the implicit association test, conceal the ultimate goal of measurement from the participant better than questionnaires. Indirect tests are especially useful when socially sensitive constructs such as attitudes towards doping need to be described. The present study serves the development and validation of a novel picture-based brief implicit association test (BIAT) for testing athletes' attitudes towards doping in sport. It shall provide the basis for a transnationally compatible research instrument able to harmonize anti-doping research efforts. Following a known-group differences validation strategy, the doping attitudes of 43 athletes from bodybuilding (representative for a highly doping prone sport) and handball (as a contrast group) were compared using the picture-based doping-BIAT. The Performance Enhancement Attitude Scale (PEAS) was employed as a corresponding direct measure in order to additionally validate the results. As expected, in the group of bodybuilders, indirectly measured doping attitudes as tested with the picture-based doping-BIAT were significantly less negative (η2 = .11). The doping-BIAT and PEAS scores correlated significantly at r = .50 for bodybuilders, and not significantly at r = .36 for handball players. There was a low error rate (7%) and a satisfactory internal consistency (rtt = .66) for the picture-based doping-BIAT. The picture-based doping-BIAT constitutes a psychometrically tested method, ready to be adopted by the international research community. The test can be administered via the internet. All test material is available "open source". The test might be implemented, for example, as a new effect-measure in the evaluation of prevention programs.

  2. Privacy-preserving genomic testing in the clinic: a model using HIV treatment

    PubMed Central

    McLaren, Paul J.; Raisaro, Jean Louis; Aouri, Manel; Rotger, Margalida; Ayday, Erman; Bartha, István; Delgado, Maria B.; Vallet, Yannick; Günthard, Huldrych F.; Cavassini, Matthias; Furrer, Hansjakob; Doco-Lecompte, Thanh; Marzolini, Catia; Schmid, Patrick; Di Benedetto, Caroline; Decosterd, Laurent A.; Fellay, Jacques; Hubaux, Jean-Pierre; Telenti, Amalio

    2016-01-01

    Purpose: The implementation of genomic-based medicine is hindered by unresolved questions regarding data privacy and delivery of interpreted results to health-care practitioners. We used DNA-based prediction of HIV-related outcomes as a model to explore critical issues in clinical genomics. Genet Med 18 8, 814–822. Methods: We genotyped 4,149 markers in HIV-positive individuals. Variants allowed for prediction of 17 traits relevant to HIV medical care, inference of patient ancestry, and imputation of human leukocyte antigen (HLA) types. Genetic data were processed under a privacy-preserving framework using homomorphic encryption, and clinical reports describing potentially actionable results were delivered to health-care providers. Genet Med 18 8, 814–822. Results: A total of 230 patients were included in the study. We demonstrated the feasibility of encrypting a large number of genetic markers, inferring patient ancestry, computing monogenic and polygenic trait risks, and reporting results under privacy-preserving conditions. The average execution time of a multimarker test on encrypted data was 865 ms on a standard computer. The proportion of tests returning potentially actionable genetic results ranged from 0 to 54%. Genet Med 18 8, 814–822. Conclusions: The model of implementation presented herein informs on strategies to deliver genomic test results for clinical care. Data encryption to ensure privacy helps to build patient trust, a key requirement on the road to genomic-based medicine. Genet Med 18 8, 814–822. PMID:26765343

  3. Development of website for studying modern physics

    NASA Astrophysics Data System (ADS)

    Saehana, S.; Wahyono, U.; Darmadi, I. W.; Kendek, Y.; Widyawati, W.

    2018-03-01

    The purpose of this study is to produce a website in modern physics courses in order to increase student interest in physics learning. To determine the feasibility level of learning media then feasibility test to the product. The feasibility test carried out on the product is divided into three parts: material feasibility test, media feasibility test, and student response test. Based on the results of the test conducted the material obtained an average score of 3.72 and categorized very well. The result of media test that was obtained got the average score of 3.25 and categorized well. The result of the analysis of student's response to the twenty students of class A (fifth semester) of physics education program FKIP UniversitasTadulako obtained an average score of 3.16 with the good category. The results showed that the website developed can be used as one of the learning media that can support the learning process of students.

  4. Test Anxiety Among College Students With Specific Reading Disability (Dyslexia): Nonverbal Ability and Working Memory as Predictors.

    PubMed

    Nelson, Jason M; Lindstrom, Will; Foels, Patricia A

    2015-01-01

    Test anxiety and its correlates were examined with college students with and without specific reading disability (RD; n = 50 in each group). Results indicated that college students with RD reported higher test anxiety than did those without RD, and the magnitude of these differences was in the medium range on two test anxiety scales. Relative to college students without RD, up to 5 times as many college students with RD reported clinically significant test anxiety. College students with RD reported significantly higher cognitively based test anxiety than physically based test anxiety. Reading skills, verbal ability, and processing speed were not correlated with test anxiety. General intelligence, nonverbal ability, and working memory were negatively correlated with test anxiety, and the magnitude of these correlations was medium to large. When these three cognitive constructs were considered together in multiple regression analyses, only working memory and nonverbal ability emerged as significant predictors and varied based on the test anxiety measure. Implications for assessment and intervention are discussed. © Hammill Institute on Disabilities 2013.

  5. A Risk-Based Approach for Aerothermal/TPS Analysis and Testing

    NASA Technical Reports Server (NTRS)

    Wright, Michael J.; Grinstead, Jay H.; Bose, Deepak

    2007-01-01

    The current status of aerothermal and thermal protection system modeling for civilian entry missions is reviewed. For most such missions, the accuracy of our simulations is limited not by the tools and processes currently employed, but rather by reducible deficiencies in the underlying physical models. Improving the accuracy of and reducing the uncertainties in these models will enable a greater understanding of the system level impacts of a particular thermal protection system and of the system operation and risk over the operational life of the system. A strategic plan will be laid out by which key modeling deficiencies can be identified via mission-specific gap analysis. Once these gaps have been identified, the driving component uncertainties are determined via sensitivity analyses. A Monte-Carlo based methodology is presented for physics-based probabilistic uncertainty analysis of aerothermodynamics and thermal protection system material response modeling. These data are then used to advocate for and plan focused testing aimed at reducing key uncertainties. The results of these tests are used to validate or modify existing physical models. Concurrently, a testing methodology is outlined for thermal protection materials. The proposed approach is based on using the results of uncertainty/sensitivity analyses discussed above to tailor ground testing so as to best identify and quantify system performance and risk drivers. A key component of this testing is understanding the relationship between the test and flight environments. No existing ground test facility can simultaneously replicate all aspects of the flight environment, and therefore good models for traceability to flight are critical to ensure a low risk, high reliability thermal protection system design. Finally, the role of flight testing in the overall thermal protection system development strategy is discussed.

  6. Automated audiometry using apple iOS-based application technology.

    PubMed

    Foulad, Allen; Bui, Peggy; Djalilian, Hamid

    2013-11-01

    The aim of this study is to determine the feasibility of an Apple iOS-based automated hearing testing application and to compare its accuracy with conventional audiometry. Prospective diagnostic study. Setting Academic medical center. An iOS-based software application was developed to perform automated pure-tone hearing testing on the iPhone, iPod touch, and iPad. To assess for device variations and compatibility, preliminary work was performed to compare the standardized sound output (dB) of various Apple device and headset combinations. Forty-two subjects underwent automated iOS-based hearing testing in a sound booth, automated iOS-based hearing testing in a quiet room, and conventional manual audiometry. The maximum difference in sound intensity between various Apple device and headset combinations was 4 dB. On average, 96% (95% confidence interval [CI], 91%-100%) of the threshold values obtained using the automated test in a sound booth were within 10 dB of the corresponding threshold values obtained using conventional audiometry. When the automated test was performed in a quiet room, 94% (95% CI, 87%-100%) of the threshold values were within 10 dB of the threshold values obtained using conventional audiometry. Under standardized testing conditions, 90% of the subjects preferred iOS-based audiometry as opposed to conventional audiometry. Apple iOS-based devices provide a platform for automated air conduction audiometry without requiring extra equipment and yield hearing test results that approach those of conventional audiometry.

  7. Integrated Rapid-Diagnostic-Test Reader Platform on a Cellphone

    PubMed Central

    Mudanyali, Onur; Dimitrov, Stoyan; Sikora, Uzair; Padmanabhan, Swati; Navruz, Isa; Ozcan, Aydogan

    2012-01-01

    We demonstrate a cellphone based Rapid-Diagnostic-Test (RDT) reader platform that can work with various lateral flow immuno-chromatographic assays and similar tests to sense the presence of a target analyte in a sample. This compact and cost-effective digital RDT reader, weighing only ~65 grams, mechanically attaches to the existing camera unit of a cellphone, where various types of RDTs can be inserted to be imaged in reflection or transmission modes under light-emitting-diode (LED) based illumination. Captured raw images of these tests are then digitally processed (within less than 0.2 sec/image) through a smart application running on the cellphone for validation of the RDT as well as for automated reading of its diagnostic result. The same smart application running on the cellphone then transmits the resulting data, together with the RDT images and other related information (e.g., demographic data) to a central server, which presents the diagnostic results on a world-map through geo-tagging. This dynamic spatio-temporal map of various RDT results can then be viewed and shared using internet browsers or through the same cellphone application. We tested this platform using malaria, tuberculosis (TB) as well as HIV RDTs by installing it on both Android based smart-phones as well as an iPhone. Providing real-time spatio-temporal statistics for the prevalence of various infectious diseases, this smart RDT reader platform running on cellphones might assist health-care professionals and policy makers to track emerging epidemics worldwide and help epidemic preparedness. PMID:22596243

  8. Range-based volatility, expected stock returns, and the low volatility anomaly

    PubMed Central

    2017-01-01

    One of the foundations of financial economics is the idea that rational investors will discount stocks with more risk (volatility), which will result in a positive relation between risk and future returns. However, the empirical evidence is mixed when determining how volatility is related to future returns. In this paper, we examine this relation using a range-based measure of volatility, which is shown to be theoretically, numerically, and empirically superior to other measures of volatility. In a variety of tests, we find that range-based volatility is negatively associated with expected stock returns. These results are robust to time-series multifactor models as well as cross-sectional tests. Our findings contribute to the debate about the direction of the relationship between risk and return and confirm the presence of the low volatility anomaly, or the anomalous finding that low volatility stocks outperform high volatility stocks. In other tests, we find that the lower returns associated with range-based volatility are driven by stocks with lottery-like characteristics. PMID:29190652

  9. HIV-Prevention Opportunities With GPS-Based Social and Sexual Networking Applications for Men Who Have Sex With Men.

    PubMed

    Jenkins Hall, Wendasha; Sun, Christina J; Tanner, Amanda E; Mann, Lilli; Stowers, Jason; Rhodes, Scott D

    2017-02-01

    The goal of this study was to gain insight on the sexual health needs of men who have sex with men (MSM) who use GPS-based social and sexual networking mobile applications (apps) and the future utility of app-based interventions. A health educator promoted HIV-testing resources in four popular apps used by MSM. Content analysis was used to identify salient themes that emerged from the conversations. Four major themes were identified: (1) soliciting sexual encounters, (2) relationship building, (3) HIV and STI-testing inquiries, and (4) seeking other sexual health information. The results suggest the intervention's social media-based strategy, respect for community culture, and unobtrusive approach was advantageous in establishing credibility and rapport with app users. These results highlight a need for convenient and discreet methods to access accurate sexual health information and suggest that apps provide an alternative, non-traditional venue for sexual health education in addition to HIV testing promotion.

  10. Range-based volatility, expected stock returns, and the low volatility anomaly.

    PubMed

    Blau, Benjamin M; Whitby, Ryan J

    2017-01-01

    One of the foundations of financial economics is the idea that rational investors will discount stocks with more risk (volatility), which will result in a positive relation between risk and future returns. However, the empirical evidence is mixed when determining how volatility is related to future returns. In this paper, we examine this relation using a range-based measure of volatility, which is shown to be theoretically, numerically, and empirically superior to other measures of volatility. In a variety of tests, we find that range-based volatility is negatively associated with expected stock returns. These results are robust to time-series multifactor models as well as cross-sectional tests. Our findings contribute to the debate about the direction of the relationship between risk and return and confirm the presence of the low volatility anomaly, or the anomalous finding that low volatility stocks outperform high volatility stocks. In other tests, we find that the lower returns associated with range-based volatility are driven by stocks with lottery-like characteristics.

  11. Validation of the tablet-administered Brief Assessment of Cognition (BAC App).

    PubMed

    Atkins, Alexandra S; Tseng, Tina; Vaughan, Adam; Twamley, Elizabeth W; Harvey, Philip; Patterson, Thomas; Narasimhan, Meera; Keefe, Richard S E

    2017-03-01

    Computerized tests benefit from automated scoring procedures and standardized administration instructions. These methods can reduce the potential for rater error. However, especially in patients with severe mental illnesses, the equivalency of traditional and tablet-based tests cannot be assumed. The Brief Assessment of Cognition in Schizophrenia (BACS) is a pen-and-paper cognitive assessment tool that has been used in hundreds of research studies and clinical trials, and has normative data available for generating age- and gender-corrected standardized scores. A tablet-based version of the BACS called the BAC App has been developed. This study compared performance on the BACS and the BAC App in patients with schizophrenia and healthy controls. Test equivalency was assessed, and the applicability of paper-based normative data was evaluated. Results demonstrated the distributions of standardized composite scores for the tablet-based BAC App and the pen-and-paper BACS were indistinguishable, and the between-methods mean differences were not statistically significant. The discrimination between patients and controls was similarly robust. The between-methods correlations for individual measures in patients were r>0.70 for most subtests. When data from the Token Motor Test was omitted, the between-methods correlation of composite scores was r=0.88 (df=48; p<0.001) in healthy controls and r=0.89 (df=46; p<0.001) in patients, consistent with the test-retest reliability of each measure. Taken together, results indicate that the tablet-based BAC App generates results consistent with the traditional pen-and-paper BACS, and support the notion that the BAC App is appropriate for use in clinical trials and clinical practice. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Satellite Vibration Testing: Angle optimisation method to Reduce Overtesting

    NASA Astrophysics Data System (ADS)

    Knight, Charly; Remedia, Marcello; Aglietti, Guglielmo S.; Richardson, Guy

    2018-06-01

    Spacecraft overtesting is a long running problem, and the main focus of most attempts to reduce it has been to adjust the base vibration input (i.e. notching). Instead this paper examines testing alternatives for secondary structures (equipment) coupled to the main structure (satellite) when they are tested separately. Even if the vibration source is applied along one of the orthogonal axes at the base of the coupled system (satellite plus equipment), the dynamics of the system and potentially the interface configuration mean the vibration at the interface may not occur all along one axis much less the corresponding orthogonal axis of the base excitation. This paper proposes an alternative testing methodology in which the testing of a piece of equipment occurs at an offset angle. This Angle Optimisation method may have multiple tests but each with an altered input direction allowing for the best match between all specified equipment system responses with coupled system tests. An optimisation process that compares the calculated equipment RMS values for a range of inputs with the maximum coupled system RMS values, and is used to find the optimal testing configuration for the given parameters. A case study was performed to find the best testing angles to match the acceleration responses of the centre of mass and sum of interface forces for all three axes, as well as the von Mises stress for an element by a fastening point. The angle optimisation method resulted in RMS values and PSD responses that were much closer to the coupled system when compared with traditional testing. The optimum testing configuration resulted in an overall average error significantly smaller than the traditional method. Crucially, this case study shows that the optimum test campaign could be a single equipment level test opposed to the traditional three orthogonal direction tests.

  13. Home-based chlamydia testing of young people attending a music festival - who will pee and post?

    PubMed Central

    2010-01-01

    Background Chlamydia is most common among young people, but only a small proportion of Australian young people are tested annually. Home-based chlamydia testing has been piloted in several countries to increase testing rates, but uptake has been low. We aimed to identify predictors of uptake of home-based chlamydia testing to inform future testing programs. Methods We offered home-based chlamydia testing kits to participants in a sexual behaviour cross-sectional survey conducted at a music festival in Melbourne, Australia. Those who consented received a testing kit and were asked to return their urine or vaginal swab sample via post. Results Nine hundred and two sexually active music festival attendees aged 16-29 completed the survey; 313 (35%) opted to receive chlamydia testing kits, and 67 of 313 (21%) returned a specimen for testing. One participant was infected with chlamydia (1% prevalence). Independent predictors of consenting to receive a testing kit included older age, knowing that chlamydia can make women infertile, reporting more than three lifetime sexual partners and inconsistent condom use. Independent predictors of returning a sample to the laboratory included knowing that chlamydia can be asymptomatic, not having had an STI test in the past six months and not living with parents. Conclusions A low proportion of participants returned their chlamydia test, suggesting that this model is not ideal for reaching young people. Home-based chlamydia testing is most attractive to those who report engaging in sexual risk behaviours and are aware of the often asymptomatic nature and potential sequelae of chlamydia infection. PMID:20584287

  14. The Diagnostic Validity of the 13C-Urea Breath Test in the Gastrectomized Patients: Single Tertiary Center Retrospective Cohort Study

    PubMed Central

    Kwon, Yong Hwan; Kim, Nayoung; Lee, Ju Yup; Choi, Yoon Jin; Yoon, Kichul; Yoon, Hyuk; Shin, Cheol Min; Park, Young Soo; Lee, Dong Ho

    2014-01-01

    Background: This study was conducted to evaluate the diagnostic validity of the 13C-urea breath test (13C-UBT) in the remnant stomach after partial gastrectomy for gastric cancer. Methods: The 13C-UBT results after Helicobacter pylori eradication therapy was compared with the results of endoscopic biopsy-based methods in the patients who have received partial gastrectomy for the gastric cancer. Results: Among the gastrectomized patients who showed the positive 13C-UBT results (≥ 2.5‰, n = 47) and negative 13C-UBT results (< 2.5‰, n = 114) after H. pylori eradication, 26 patients (16.1%) and 4 patients (2.5%) were found to show false positive and false negative results based on biopsy-based methods, respectively. The sensitivity, specificity, false positive rate, and false negative rate for the cut-off value of 2.5‰ were 84.0%, 80.9%, 19.1%, and 16.0%, respectively. The positive and negative predictive values were 44.7% and 96.5%, respectively. In the multivariate analysis, two or more H. pylori eradication therapies (odds ratio = 3.248, 95% confidence interval= 1.088–9.695, P = 0.035) was associated with a false positive result of the 13C-UBT. Conclusions: After partial gastrectomy, a discordant result was shown in the positive 13C-UBT results compared to the endoscopic biopsy methods for confirming the H. pylori status after eradication. Additional endoscopic biopsy-based H. pylori tests would be helpful to avoid unnecessary treatment for H. pylori eradication in these cases. PMID:25574466

  15. Cost-effectiveness of anatomical and functional test strategies for stable chest pain: public health perspective from a middle-income country.

    PubMed

    Bertoldi, Eduardo G; Stella, Steffen F; Rohde, Luis Eduardo P; Polanczyk, Carisi A

    2017-05-04

    The aim of this research is to evaluate the relative cost-effectiveness of functional and anatomical strategies for diagnosing stable coronary artery disease (CAD), using exercise (Ex)-ECG, stress echocardiogram (ECHO), single-photon emission CT (SPECT), coronary CT angiography (CTA) or stress cardiacmagnetic resonance (C-MRI). Decision-analytical model, comparing strategies of sequential tests for evaluating patients with possible stable angina in low, intermediate and high pretest probability of CAD, from the perspective of a developing nation's public healthcare system. Hypothetical cohort of patients with pretest probability of CAD between 20% and 70%. The primary outcome is cost per correct diagnosis of CAD. Proportion of false-positive or false-negative tests and number of unnecessary tests performed were also evaluated. Strategies using Ex-ECG as initial test were the least costly alternatives but generated more frequent false-positive initial tests and false-negative final diagnosis. Strategies based on CTA or ECHO as initial test were the most attractive and resulted in similar cost-effectiveness ratios (I$ 286 and I$ 305 per correct diagnosis, respectively). A strategy based on C-MRI was highly effective for diagnosing stable CAD, but its high cost resulted in unfavourable incremental cost-effectiveness (ICER) in moderate-risk and high-risk scenarios. Non-invasive strategies based on SPECT have been dominated. An anatomical diagnostic strategy based on CTA is a cost-effective option for CAD diagnosis. Functional strategies performed equally well when based on ECHO. C-MRI yielded acceptable ICER only at low pretest probability, and SPECT was not cost-effective in our analysis. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. A Community-Based IoT Personalized Wireless Healthcare Solution Trial.

    PubMed

    Catherwood, Philip A; Steele, David; Little, Mike; Mccomb, Stephen; Mclaughlin, James

    2018-01-01

    This paper presents an advanced Internet of Things point-of-care bio-fluid analyzer; a LoRa/Bluetooth-enabled electronic reader for biomedical strip-based diagnostics system for personalized monitoring. We undertake test simulations (technology trial without patient subjects) to demonstrate potential of long-range analysis, using a disposable test 'key' and companion Android app to form a diagnostic platform suitable for remote point-of-care screening for urinary tract infection (UTI). The 868 MHz LoRaWAN-enabled personalized monitor demonstrated sound potential with UTI test results being correctly diagnosed and transmitted to a remote secure cloud server in every case. Tests ranged over distances of 1.1-6.0 Km with radio path losses from 119-141 dB. All tests conducted were correctly and robustly received at the base station and relayed to the secure server for inspection. The UTI test strips were visually inspected for correct diagnosis based on color change and verified as 100% accurate. Results from testing across a number of regions indicate that such an Internet of Things medical solution is a robust and simple way to deliver next generation community-based smart diagnostics and disease management to best benefit patients and clinical staff alike. This significant step can be applied to any type of home or region, particularly those lacking suitable mobile signals, broadband connections, or even landlines. It brings subscription-free long-range bio-telemetry to healthcare providers and offers savings on regular clinician home visits or frequent clinic visits by the chronically ill. This paper highlights practical hurdles in establishing an Internet of Medical Things network, assisting informed deployment of similar future systems.

  17. A Community-Based IoT Personalized Wireless Healthcare Solution Trial

    PubMed Central

    Steele, David; Little, Mike; Mccomb, Stephen; Mclaughlin, James

    2018-01-01

    This paper presents an advanced Internet of Things point-of-care bio-fluid analyzer; a LoRa/Bluetooth-enabled electronic reader for biomedical strip-based diagnostics system for personalized monitoring. We undertake test simulations (technology trial without patient subjects) to demonstrate potential of long-range analysis, using a disposable test ‘key’ and companion Android app to form a diagnostic platform suitable for remote point-of-care screening for urinary tract infection (UTI). The 868 MHz LoRaWAN-enabled personalized monitor demonstrated sound potential with UTI test results being correctly diagnosed and transmitted to a remote secure cloud server in every case. Tests ranged over distances of 1.1–6.0 Km with radio path losses from 119–141 dB. All tests conducted were correctly and robustly received at the base station and relayed to the secure server for inspection. The UTI test strips were visually inspected for correct diagnosis based on color change and verified as 100% accurate. Results from testing across a number of regions indicate that such an Internet of Things medical solution is a robust and simple way to deliver next generation community-based smart diagnostics and disease management to best benefit patients and clinical staff alike. This significant step can be applied to any type of home or region, particularly those lacking suitable mobile signals, broadband connections, or even landlines. It brings subscription-free long-range bio-telemetry to healthcare providers and offers savings on regular clinician home visits or frequent clinic visits by the chronically ill. This paper highlights practical hurdles in establishing an Internet of Medical Things network, assisting informed deployment of similar future systems. PMID:29888145

  18. Program evaluation of Protovation Camp

    NASA Astrophysics Data System (ADS)

    Healy, Laurel Lynell Martin

    The purpose of this program evaluation was to determine the extent to which Protovation Camp utilized the combined resources of multiple institutions to impact student learning in science, technology, engineering, and math. The partnership consisted of multiple institutions: the university, providing graduate students to facilitate inquiry-based lessons; the science center, allowing the use of their facilities and resources; and the elementary school, contributing rising third through fifth grade campers. All of these components were examined. The mixed-methods approach used post hoc quantitative data for campers, which consisted of pre-test and post-test scores on the Test of Science-Related Attitudes (TOSRA), the Draw-A-Scientist Test, and content tests based on the camp activities. Additionally, TOSRA scores and current survey results for the graduate students were used along with qualitative data collected from plusdelta charts to determine the impact of participation in Protovation Camp on teachers and students. Results of the program evaluation indicated that when students were taught inquiry-based lessons that ignite wonder, both their attitudes toward science and their knowledge about science improved. An implication for teacher preparation programs was that practicing inquiry-based lessons on actual students (campers) was an important component for teachers (graduate students) as they prepare to positively impact student learning in their own classrooms. Immediate feedback from the campers in the form of pre-test and post-test scores and from peers on plusdelta charts allowed the graduate students the opportunity to make needed adjustments to improve effectiveness before using the lesson with a new set of campers or later in their own classrooms. Keywords. Teacher preparation, Inquiry-based instruction, STEM instructions, University and museum partnerships

  19. A robust method using propensity score stratification for correcting verification bias for binary tests

    PubMed Central

    He, Hua; McDermott, Michael P.

    2012-01-01

    Sensitivity and specificity are common measures of the accuracy of a diagnostic test. The usual estimators of these quantities are unbiased if data on the diagnostic test result and the true disease status are obtained from all subjects in an appropriately selected sample. In some studies, verification of the true disease status is performed only for a subset of subjects, possibly depending on the result of the diagnostic test and other characteristics of the subjects. Estimators of sensitivity and specificity based on this subset of subjects are typically biased; this is known as verification bias. Methods have been proposed to correct verification bias under the assumption that the missing data on disease status are missing at random (MAR), that is, the probability of missingness depends on the true (missing) disease status only through the test result and observed covariate information. When some of the covariates are continuous, or the number of covariates is relatively large, the existing methods require parametric models for the probability of disease or the probability of verification (given the test result and covariates), and hence are subject to model misspecification. We propose a new method for correcting verification bias based on the propensity score, defined as the predicted probability of verification given the test result and observed covariates. This is estimated separately for those with positive and negative test results. The new method classifies the verified sample into several subsamples that have homogeneous propensity scores and allows correction for verification bias. Simulation studies demonstrate that the new estimators are more robust to model misspecification than existing methods, but still perform well when the models for the probability of disease and probability of verification are correctly specified. PMID:21856650

  20. Evaluation and simplification of the occupational slip, trip and fall risk-assessment test

    PubMed Central

    NAKAMURA, Takehiro; OYAMA, Ichiro; FUJINO, Yoshihisa; KUBO, Tatsuhiko; KADOWAKI, Koji; KUNIMOTO, Masamizu; ODOI, Haruka; TABATA, Hidetoshi; MATSUDA, Shinya

    2016-01-01

    Objective: The purpose of this investigation is to evaluate the efficacy of the occupational slip, trip and fall (STF) risk assessment test developed by the Japan Industrial Safety and Health Association (JISHA). We further intended to simplify the test to improve efficiency. Methods: A previous cohort study was performed using 540 employees aged ≥50 years who took the JISHA’s STF risk assessment test. We conducted multivariate analysis using these previous results as baseline values and answers to questionnaire items or score on physical fitness tests as variables. The screening efficiency of each model was evaluated based on the obtained receiver operating characteristic (ROC) curve. Results: The area under the ROC obtained in multivariate analysis was 0.79 when using all items. Six of the 25 questionnaire items were selected for stepwise analysis, giving an area under the ROC curve of 0.77. Conclusion: Based on the results of follow-up performed one year after the initial examination, we successfully determined the usefulness of the STF risk assessment test. Administering a questionnaire alone is sufficient for screening subjects at risk of STF during the subsequent one-year period. PMID:27021057

Top