Self-aligning biaxial load frame
Ward, M.B.; Epstein, J.S.; Lloyd, W.R.
1994-01-18
An self-aligning biaxial loading apparatus for use in testing the strength of specimens while maintaining a constant specimen centroid during the loading operation. The self-aligning biaxial loading apparatus consists of a load frame and two load assemblies for imparting two independent perpendicular forces upon a test specimen. The constant test specimen centroid is maintained by providing elements for linear motion of the load frame relative to a fixed cross head, and by alignment and linear motion elements of one load assembly relative to the load frame. 3 figures.
Self-aligning biaxial load frame
Ward, Michael B.; Epstein, Jonathan S.; Lloyd, W. Randolph
1994-01-01
An self-aligning biaxial loading apparatus for use in testing the strength of specimens while maintaining a constant specimen centroid during the loading operation. The self-aligning biaxial loading apparatus consists of a load frame and two load assemblies for imparting two independent perpendicular forces upon a test specimen. The constant test specimen centroid is maintained by providing elements for linear motion of the load frame relative to a fixed crosshead, and by alignment and linear motion elements of one load assembly relative to the load frame.
Oxygen index tests of thermosetting resins
NASA Technical Reports Server (NTRS)
Gilwee, W. J., Jr.; Parker, J. A.; Kourtides, D. A.
1980-01-01
The flammability characteristics of nine thermosetting resins under evaluation for use in aircraft interiors are described. These resins were evaluated using the Oxygen Index (ASTM 2863) testing procedure. The test specimens consisted of both neat resin and glass reinforced resin. When testing glass-reinforced samples it was observed that Oxygen Index values varied inversely with resin content. Oxygen values were also obtained on specimens exposed to temperatures up to 300 C. All specimens experienced a decline in Oxygen Index when tested at an elevated temperature.
NASA Astrophysics Data System (ADS)
LaCoursiere, M. P.; Aidun, D. K.; Morrison, D. J.
2017-05-01
The hydrogen embrittlement susceptibility of near-peak-aged UNS N07718 (Alloy 718) was evaluated by performing slow strain rate tests at room temperature in air and substitute ocean water. Tests in substitute ocean water were accomplished in an environmental cell that enabled in situ cathodic charging under an applied potential of -1.1 V versus SCE. Some specimens were cathodically precharged for 4 or 16 weeks at the same potential in a 3.5 wt.% NaCl-distilled water solution at 50 °C. Unprecharged specimens tested in substitute ocean water exhibited only moderate embrittlement with plastic strain to failure decreasing by about 20% compared to unprecharged specimens tested in air. However, precharged specimens exhibited significant embrittlement with plastic strain to failure decreasing by about 70%. Test environment (air or substitute ocean water with in situ charging) and precharge time (4 or 16 weeks) had little effect on the results of the precharged specimens. Fracture surfaces of precharged specimens were typical of hydrogen embrittlement and consisted of an outer brittle ring related to the region in which hydrogen infused during precharging, a finely dimpled transition zone probably related to the region where hydrogen was drawn in by dislocation transport, and a central highly dimpled ductile region. Fracture surfaces of unprecharged specimens tested in substitute ocean water consisted of a finely dimpled outer ring and heavily dimpled central region typical of ductile fracture.
Fabrication and testing of prestressed composite rotor blade spar specimens
NASA Technical Reports Server (NTRS)
Gleich, D.
1974-01-01
Prestressed composite spar specimens were fabricated and evaluated by crack propagation and ballistic penetration tests. The crack propagation tests on flawed specimens showed that the prestressed composite spar construction significantly suppresses crack growth. Damage from three high velocity 30 caliber projectile hits was confined to three small holes in the ballistic test specimen. No fragmentation or crack propagation was observed indicating good ballistic damage resistance. Rotor attachment approaches and improved structural performance configurations were identified. Design theory was verified by tests. The prestressed composite spar configuration consisted of a compressively prestressed high strength ARDEFORM 301 stainless steel liner overwrapped with pretensioned S-994 fiberglass.
NASA Technical Reports Server (NTRS)
Mcdaniel, R. H.; Bradford, E. W.; Lewis, J. H.; Wattier, J. B.
1973-01-01
Specimens fabricated from structural materials that were candidates for certain NERVA applications were irradiated in liquid nitrogen (LN2), liquid hydrogen (LH2), water, and air. The specimens irradiated in LN2 were stored in LN2 and finally tested in LN2, or at some higher temperature in a few instances. The specimens irradiated in LH2 underwent an unplanned warmup while in storage so this portion of the test was lost; some specimens were tested in LN2 but none were tested in LH2. The Ground Test Reactor was the radiation source. The test specimens consisted mainly of tensile and fracture toughness specimens of several different materials, but other types of specimens such as tear, flexure, springs, and lubricant were also irradiated. Materials tested include Hastelloy X, Al, Ni steel, steel, Be, ZrC, Ti-6Al-4V, CuB, and Ti-5Al-2.5Sn.
Glass fibre-reinforced composite laced with chlorhexidine digluconate and yeast adhesion.
Waltimo, T; Luo, G; Samaranayake, L P; Vallittu, P K
2004-02-01
The aim of this study was to lace dental glass fibre reinforced composite (FRC) prepreg with chlorhexidine digluconate and to examine the adherence of common oral fungal pathogen Candida albicans to FRC made of the prepreg. Four different test and control material groups each comprising 16 test specimens ((5.0 x 5.0 x 0.8) mm3) each were used as substrates for C. albicans adherence. A porous polymer pre-impregnated woven glass fibre prepreg was laced with solution of chlorhexidine gluconate and it was used with autopolymerized denture base polymer to fabricate FRC test specimens. Control group (Group 1) consisted of FRC test specimens stored in water. In Group 2, the test specimens were stored in 10% chlorhexidine digluconate solution for 24 h. Group 3 consisted of specimens fabricated using such fibre reinforcements which were pre-soaked in 20% chlorhexidine digluconate and dried before preparation with denture base resin, and followed by storage of the specimens in water. Group 4 was similar to Group 3 but instead of water storage the specimens were immersed in 10% chlorhexidine digluconate for 24 h. For the candidal adhesion assay the test and control specimens were incubated in standardized suspensions of four different strains of C. albicans, rinsed and prepared for light-microscopy. The mean number of adherent cells in each group was counted microscopically and analysed statistically. There were significantly (P < 0.05) more adherent C. albicans cells found in Group 1 than in the other three groups which did not differ significantly from each other. The lowest numbers of adherent cells were found in Group 3. Pretreating the porous polymer pre-impregnated glass fibre reinforcement with chlorhexidine digluconate result in reduction in the number of adherent yeast cells on the surface FRC material.
Hypervelocity penetration against mechanical properties of target materials
NASA Astrophysics Data System (ADS)
Kamarudin, Khairul Hasni; Abdullah, Mohamad Faizal; Zaidi, Ahmad Mujahid Ahmad; Nor, Norazman M.; Ismail, Ariffin; Yusof, Mohammed Alias; Hilmi, Ahmad Humaizi
2018-02-01
This paper study the mechanical properties behavior of metal plates against hypervelocity penetration caused by shaped charge. Five different materials were used as target specimen fabricated from welded stacks of material plates, namely Rolled Homogeneous Armor (RHA), Hardox-500, mild steel, aluminum and brass. Specimens had undergone an initial monolithic test consist of tensile tests and microstructure observations, followed by series of hydrodynamics penetration blast tests using shape charge mechanism. Results from blast test shows that the least penetrated specimen is RHA (58mm) followed by Hardox-500 (92 mm), mild steel (110 mm), Brass (155 mm) and aluminum 238 mm). Comparing these with the specimen yield strength from the tensile test results shows that Hardox-500 has higher yield strength (Sy) followed by RHA, mild steel, brass and aluminum, which are 1370 MPa, 1320 MPa, 280,221 respectively, which are not inversely proportional to the penetration. However, the ultimate tensile strength (Sut) where the RHA were the highest followed by Hardox-500, mild steel, brass and aluminum, were inversely proportional with the depth of penetration. The penetration results also show consistence relation with energy absorption.
Rolling contact fatigue of surface modified 440C using a 'Ge-Polymet' type disc rod test rig
NASA Technical Reports Server (NTRS)
Thom, Robert L.
1989-01-01
Through hardened 440 C martensitic stainless steel test specimens were surface modified and tested for changes in rolling contact fatigue using a disc on rod test rig. The surface modifications consisted of nitrogen, boron, titanium, chromium, tantalum, carbon, or molybdenum ion implantation at various ion fluences and energies. Tests were also performed on specimens reactively sputtered with titanium nitride.
Investigating Delamination Migration in Composite Tape Laminates
NASA Technical Reports Server (NTRS)
Ratcliffe, James G.; DeCarvalho, Nelson V.
2014-01-01
A modification to a recently developed test specimen designed to investigate migration of a delamination between neighboring ply interfaces in tape laminates is presented. The specimen is a cross-ply laminated beam consisting of 40 plies with a polytetrafluoroethylene insert spanning part way along its length. The insert is located between a lower 0-degree ply (specimen length direction) and a stack of four 90-degree plies (specimen width direction). The modification involved a stacking sequence that promotes stable delamination growth prior to migration, and included a relocation of the insert from the specimen midplane to the interface between plies 14 and 15. Specimens were clamped at both ends onto a rigid baseplate and loaded on their upper surface via a piano hinge assembly, resulting in a predominantly flexural loading condition. Tests were conducted with the load-application point positioned at various locations along a specimen's span. This position affected the sequence of damage events during a test.
Lee, Byung Jae; Bang, Jin Wook; Shin, Kyung Joon; Kim, Yun Yong
2014-12-08
In this study, adiabatic temperature rise tests depending on binder type and adiabatic specimen volume were performed, and the maximum adiabatic temperature rises and the reaction factors for each mix proportion were analyzed and suggested. The results indicated that the early strength low heat blended cement mixture had the lowest maximum adiabatic temperature rise ( Q ∞ ) and the ternary blended cement mixture had the lowest reaction factor ( r ). Also, Q and r varied depending on the adiabatic specimen volume even when the tests were conducted with a calorimeter, which satisfies the recommendations for adiabatic conditions. Test results show a correlation: the measurements from the 50 L specimens were consistently higher than those from the 6 L specimens. However, the Q ∞ and r values of the 30 L specimen were similar to those of the 50 L specimen. Based on the above correlation, the adiabatic temperature rise of the 50 L specimen could be predicted using the results of the 6 L and 30 L specimens. Therefore, it is thought that this correlation can be used for on-site concrete quality control and basic research.
Klatte, J Michael; Selvarangan, Rangaraj; Jackson, Mary Anne; Myers, Angela L
2016-01-01
Study objectives included addressing overuse of Clostridium difficile laboratory testing by decreasing submission rates of nondiarrheal stool specimens and specimens from children ≤12 months of age and determining resultant patient and laboratory cost savings associated with decreased testing. A multifaceted initiative was developed, and components included multiple provider education methods, computerized order entry modifications, and automatic declination from laboratory on testing stool specimens of nondiarrheal consistency and from children ≤12 months old. A run chart, demonstrating numbers of nondiarrheal plus infant stool specimens submitted over time, was developed to analyze the initiative's impact on clinicians' test-ordering practices. A p-chart was generated to evaluate the percentage of these submitted specimens tested biweekly over a 12-month period. Cost savings for patients and the laboratory were assessed at the study period's conclusion. Run chart analysis revealed an initial shift after the interventions, suggesting a temporary decrease in testing submission; however, no sustained differences in numbers of specimens submitted biweekly were observed over time. On the p-chart, the mean percentage of specimens tested before the intervention was 100%. After the intervention, the average percentage of specimens tested dropped to 53.8%. Resultant laboratory cost savings totaled nearly $3600, and patient savings on testing charges were ∼$32 000. Automatic laboratory declination of nondiarrheal stools submitted for CDI testing resulted in a sustained decrease in the number of specimens tested, resulting in significant laboratory and patient cost savings. Despite multiple educational efforts, no sustained changes in physician ordering practices were observed. Copyright © 2016 by the American Academy of Pediatrics.
Standard Methods for Unnotched Tension Testing of Textile Composites
NASA Technical Reports Server (NTRS)
Portanova, M. A.
1995-01-01
An investigation was conducted by researchers at the Boeing Defense & Space Group to investigate the effects of specimen sizing on several braided textile materials. Test results from this and other test programs were compared in an effort to determine what effect, if any, specimen size has on elastic property measurements of unnotched tension test. In general, the unnotched tensile strength of 2-D braids was found to be insensitive to specimen width, length, or thickness effects. The results from this study suggest that standard testing methods used for tape materials may be sufficient for tension testing of textile composite materials. Specifically, the straight sided specimen geometry described in ASTM 3034, and used by Boeing, should provide acceptable results. Further experiments performed at Boeing and by other investigators on other textile architectures suggest similar results. Although specimen size studies were not conducted, failing stresses varied on the same order as those obtained with the 2-D materials. This suggests that the accuracy of the results were consistent with those obtained with the 2-D materials.
Edgeless composite laminate specimen for static and fatigue testing
NASA Technical Reports Server (NTRS)
Liber, T.; Daniel, I. M.
1978-01-01
The influence of edge effects on the tensile properties of angle-ply laminate composites can be eliminated by using edgeless (round tubular) specimens. However, uniaxial tests with such specimens, static and fatigue, have been generally unsuccessful because of the differential Poisson effect between the test section and the grips. An edgeless cylindrical specimen, developed to circumvent these difficulties, is examined in the present paper. It is a flattened tube consisting of two flat sides connected by curved sections. It can be handled much like the standard flat coupon. The flat ends of the specimen are provided with crossplied fiberglass gripping tabs, the same as used for flat test coupons. As part of the tabbing, the hollow ends must be plugged with inserts to prevent crushing of the ends. A special insert design was developed to minimize detrimental Poisson effects ordinarily introduced by inserts.
46 CFR 164.009-15 - Test procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... material, is less than 47 mm, the specimens prepared consist of layers of the sample. (3) If the sample is a composite material and has a height that is not 50 ±3mm, the layers of the specimen prepared are proportional in thickness to the layers of the sample. (4) The top and bottom faces of each specimen prepared...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kubouchi, Masatoshi; Hojo, Hidemitsu
The thermal shock resistance of epoxy resin specimens toughened with carboxy-terminated poly(butadiene-acrylonitrile) (CTBN) and poly-glycol were tested using a new notched disk-type specimen. The new thermal shock testing method consists of quenching a notched disk-type specimen and applying a theoretical analysis to the test results to determine crack propagation conditions. For both toughened epoxy resins, this test method evaluated improvements in thermal shock resistance. The thermal shock resistance of epoxy resin toughened with CTBN exhibited a maximum at a 35 parts per hundred resin content of CTBN. The epoxy resin toughened with polyglycol exhibited improved thermal shock resistance with increasingmore » glycol content. 7 refs., 14 figs., 1 tab.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Y.; Chopra, O. K.; Soppet, W. K.
2010-02-16
Cracking behavior of stainless steels specimens irradiated in the BOR-60 at about 320 C is studied. The primary objective of this research is to improve the mechanistic understanding of irradiation-assisted stress corrosion cracking (IASCC) of core internal components under conditions relevant to pressurized water reactors. The current report covers several baseline tests in air, a comparison study in high-dissolved-oxygen environment, and TEM characterization of irradiation defect structure. Slow strain rate tensile (SSRT) tests were conducted in air and in high-dissolved-oxygen (DO) water with selected 5- and 10-dpa specimens. The results in high-DO water were compared with those from earlier testsmore » with identical materials irradiated in the Halden reactor to a similar dose. The SSRT tests produced similar results among different materials irradiated in the Halden and BOR-60 reactors. However, the post-irradiation strength for the BOR-60 specimens was consistently lower than that of the corresponding Halden specimens. The elongation of the BOR-60 specimens was also greater than that of their Halden specimens. Intergranular cracking in high-DO water was consistent for most of the tested materials in the Halden and BOR-60 irradiations. Nonetheless, the BOR-60 irradiation was somewhat less effective in stimulating IG fracture among the tested materials. Microstructural characterization was also carried out using transmission electron microscopy on selected BOR-60 specimens irradiated to {approx}25 dpa. No voids were observed in irradiated austenitic stainless steels and cast stainless steels, while a few voids were found in base and grain-boundary-engineered Alloy 690. All the irradiated microstructures were dominated by a high density of Frank loops, which varied in mean size and density for different alloys.« less
Ohlinger, L.A.; Seitz, F.; Young, G.J.
1959-02-17
Test-hole construction in a reactor to facilitate inserting and removing test specimens from the reactor for irradiation therein is discussed. An elongated chamber extends from the outer face of the reactor shield into the reactor. A shield box, having an open end, is sealed to thc outer face of the reactor shield by its open end surrounding the outer end of the chamber. A removable door is provided in the side wall of the shield box for inscrtion and removal of test specimens. A means operable from thc exterior of the shield box is provided for transferring test specimens between the shield box and the irradiation position within the chamber and consists of an elongated rod having a specimen tray engaging member on its inner end, which may be manipulated by the operator.
NASA Technical Reports Server (NTRS)
Witte, W. G., Jr.
1985-01-01
One of the experiments aboard the NASA Long Duration Exposure Facility (LDEF) consists of a tray of approximately one hundred tensile specimens of several candidate space structure composite materials. During the LDEF flight the materials will be subjected to the space environment and to possible contamination during launch and recovery. Tensile tests of representative samples were made before the LDEF flight to obtain baseline data. Similar tests will be made on control specimens stored on earth for the length of the LDEF flight and on recovered flight specimens. This manual codifies the details of testing, data acquisition, and handling used in obtaining the baseline data so that the same procedures and equipment will be used on the subsequent tests.
16 CFR 1615.4 - Test procedure.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) Specimen holder. The specimen holder is designed to permit suspension of the specimen in a fixed vertical... series of loads for char length determinations. Suitable metal hooks consist of No. 19 gauge steel wire... least 8 h at 21±1.1 °C (70±2 °F) and 65±2 pct relative humidity. Shorter conditioning times may be used...
Performance of lap splices in large-scale column specimens affected by ASR and/or DEF.
DOT National Transportation Integrated Search
2012-06-01
This research program conducted a large experimental program, which consisted of the design, construction, : curing, deterioration, and structural load testing of 16 large-scale column specimens with a critical lap splice : region, and then compared ...
Dynamic compressive behavior of Pr-Nd alloy at high strain rates and temperatures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Huanran; Cai Canyuan; Chen Danian
2012-07-01
Based on compressive tests, static on 810 material test system and dynamic on the first compressive loading in split Hopkinson pressure bar (SHPB) tests for Pr-Nd alloy cylinder specimens at high strain rates and temperatures, this study determined a J-C type [G. R. Johnson and W. H. Cook, in Proceedings of Seventh International Symposium on Ballistics (The Hague, The Netherlands, 1983), pp. 541-547] compressive constitutive equation of Pr-Nd alloy. It was recorded by a high speed camera that the Pr-Nd alloy cylinder specimens fractured during the first compressive loading in SHPB tests at high strain rates and temperatures. From highmore » speed camera images, the critical strains of the dynamic shearing instability for Pr-Nd alloy in SHPB tests were determined, which were consistent with that estimated by using Batra and Wei's dynamic shearing instability criterion [R. C. Batra and Z. G. Wei, Int. J. Impact Eng. 34, 448 (2007)] and the determined compressive constitutive equation of Pr-Nd alloy. The transmitted and reflected pulses of SHPB tests for Pr-Nd alloy cylinder specimens computed with the determined compressive constitutive equation of Pr-Nd alloy and Batra and Wei's dynamic shearing instability criterion could be consistent with the experimental data. The fractured Pr-Nd alloy cylinder specimens of compressive tests were investigated by using 3D supper depth digital microscope and scanning electron microscope.« less
NASA Astrophysics Data System (ADS)
Yoon, Kyung-Beom; Park, Won-Hee
2015-04-01
The convective heat transfer coefficient and surface emissivity before and after flame occurrence on a wood specimen surface and the flame heat flux were estimated using the repulsive particle swarm optimization algorithm and cone heater test results. The cone heater specified in the ISO 5660 standards was used, and six cone heater heat fluxes were tested. Preservative-treated Douglas fir 21 mm in thickness was used as the wood specimen in the tests. This study confirmed that the surface temperature of the specimen, which was calculated using the convective heat transfer coefficient, surface emissivity and flame heat flux on the wood specimen by a repulsive particle swarm optimization algorithm, was consistent with the measured temperature. Considering the measurement errors in the surface temperature of the specimen, the applicability of the optimization method considered in this study was evaluated.
Hypervelocity Impact Test Results for a Metallic Thermal Protection System
NASA Technical Reports Server (NTRS)
Karr, Katherine L.; Poteet, Carl C.; Blosser, Max L.
2003-01-01
Hypervelocity impact tests have been performed on specimens representing metallic thermal protection systems (TPS) developed at NASA Langley Research Center for use on next-generation reusable launch vehicles (RLV). The majority of the specimens tested consists of a foil gauge exterior honeycomb panel, composed of either Inconel 617 or Ti-6Al-4V, backed with 2.0 in. of fibrous insulation and a final Ti-6Al-4V foil layer. Other tested specimens include titanium multi-wall sandwich coupons as well as TPS using a second honeycomb sandwich in place of the foil backing. Hypervelocity impact tests were performed at the NASA Marshall Space Flight Center Orbital Debris Simulation Facility. An improved test fixture was designed and fabricated to hold specimens firmly in place during impact. Projectile diameter, honeycomb sandwich material, honeycomb sandwich facesheet thickness, and honeycomb core cell size were examined to determine the influence of TPS configuration on the level of protection provided to the substructure (crew, cabin, fuel tank, etc.) against micrometeoroid or orbit debris impacts. Pictures and descriptions of the damage to each specimen are included.
Mechanical Properties of Degraded PMR-15 Resin
NASA Technical Reports Server (NTRS)
Tsuji, Luis C.
2000-01-01
Thermo-oxidative aging produces a nonuniform degradation state in PMR-15 resin. A surface layer, usually attributed to oxidative degradation, forms. This surface layer has different properties from the inner material. A set of material tests was designed to separate the properties of the oxidized surface layer from the properties of interior material. Test specimens were aged at 316 C in either air or nitrogen, for durations of up to 800 hr. The thickness of the oxidized surface layer in air aged specimens, and the shrinkage and coefficient of thermal expansion (CTE) of nitrogen aged specimens were measured directly. The nitrogen-aged specimens were assumed to have the same properties as the interior material in the air-aged specimens. Four-point-bend tests were performed to determine modulus of both the oxidized surface layer and the interior material. Bimaterial strip specimens consisting of oxidized surface material and unoxidized interior material were constructed and used to determine surface layer shrinkage and CTE. Results confirm that the surface layer and core materials have substantially different properties.
Characterizing Facesheet/Core Disbonding in Honeycomb Core Sandwich Structure
NASA Technical Reports Server (NTRS)
Rinker, Martin; Ratcliffe, James G.; Adams, Daniel O.; Krueger, Ronald
2013-01-01
Results are presented from an experimental investigation into facesheet core disbonding in carbon fiber reinforced plastic/Nomex honeycomb sandwich structures using a Single Cantilever Beam test. Specimens with three, six and twelve-ply facesheets were tested. Specimens with different honeycomb cores consisting of four different cell sizes were also tested, in addition to specimens with three different widths. Three different data reduction methods were employed for computing apparent fracture toughness values from the test data, namely an area method, a compliance calibration technique and a modified beam theory method. The compliance calibration and modified beam theory approaches yielded comparable apparent fracture toughness values, which were generally lower than those computed using the area method. Disbonding in the three-ply facesheet specimens took place at the facesheet/core interface and yielded the lowest apparent fracture toughness values. Disbonding in the six and twelve-ply facesheet specimens took place within the core, near to the facesheet/core interface. Specimen width was not found to have a significant effect on apparent fracture toughness. The amount of scatter in the apparent fracture toughness data was found to increase with honeycomb core cell size.
NASA Technical Reports Server (NTRS)
Arvin, G. H.; Israeli, L.; Stolpestad, J. H.; Stacher, G. W.
1981-01-01
The application of the superplastic forming/diffusion bonding (SPF/DB) process to supersonic cruise research is investigated. The capability of an SPF/DB titanium structure to meet the structural requirements of the inner wing area of the NASA arrow-wing advanced supersonic transport design is evaluated. Selection of structural concepts and their optimization for minimum weight, SPF/DB process optimization, fabrication of representative specimens, and specimen testing and evaluation are described. The structural area used includes both upper and lower wing panels, where the upper wing panel is used for static compression strength evaluation and the lower panel, in tension, is used for fracture mechanics evaluations. The individual test specimens, cut from six large panels, consist of 39 static specimens, 10 fracture mechanics specimens, and one each full size panel for compression stability and fracture mechanics testing. Tests are performed at temperatures of -54 C (-65 F), room temperature, and 260 C (500 F).
NASA Technical Reports Server (NTRS)
Watson, G. K.
1974-01-01
Simulated nuclear fuel element specimens, consisting of uranium mononitride (UN) fuel cylinders clad with tungsten-lined T-111, were exposed for up to 7500 hr at 1040 C (1900 F) in a pumped-lithium loop. The lithium flow velocity was 1.5 m/sec (5 ft/sec) in the specimen test section. No evidence of any compatibility problems between the specimens and the flowing lithium was found based on appearance, weight change, chemistry, and metallography. Direct exposure of the UN to the lithium through a simulated cladding crack resulted in some erosion of the UN in the area of the defect. The T-111 cladding was ductile after lithium exposure, but it was sensitive to hydrogen embrittlement during post-test handling.
Spectrum fatigue testing of T-shaped tension clips
NASA Astrophysics Data System (ADS)
Palmberg, Bjoern; Wallstenius, Bengt
1992-12-01
An investigation of strain distributions during static loading and crack propagation and fatigue lives under spectrum loading of T-shaped tension clips was carried out. Three slightly different, with respect to geometry, T shaped tension clips made of aluminum alloy 7010-T73651 were studied. The type 1 and 4 test specimens were different only with respect to the web thickness of the clamping end. The type 1 and 2 test specimens were different with repect to milled flat circular countersink around the holes in the type 2 specimens and with respect to the radius between the web and foot. The spectrum fatigue loading consisted of a load sequence representative for the wing root, lower side, of a fighter aircraft. Tests were made at two different load levels for each specimen type. The strain measurements show that the countersink in the type 2 specimens increases the stresses in the fatigue critical region. This is also manifested in the spectrum fatigue life results, where type 2 specimens show the shortest fatigue lives. The strain measurements show that the torque used for the bolts in joining two test specimens or one test specimen and a dummy has a rather large impact on the strain in the fatigue region. The strains decrease with increasing torque. The spectrum fatigue loading resulted in approximately an equal number of flights to obtain a 10.0 mm crack for specimens of type 1 and 4. This suggests that the type 1 configuration is superior since the web thickness is smaller for this type as compared to the type 4 specimens. In other words, the type 4 specimens have an unnecessary oversize of the clamping end web thickness.
DOT National Transportation Integrated Search
2015-03-01
A large experimental program, consisting of the design, construction, curing, exposure, and structural load : testing of 16 large-scale column specimens with a critical lap splice region that were influenced by varying : stages of alkali-silica react...
Physical properties of concrete made with Apollo 16 lunar soil sample
NASA Technical Reports Server (NTRS)
Lin, T. D.; Love, H.; Stark, D.
1992-01-01
This paper describes the first phase of the long-term investigation for the construction of concrete lunar bases. In this phase, petrographic and scanning electron microscope examinations showed that the morphology and elemental composition of the lunar soil made it suitable for use as a fine aggregate for concrete. Based on this finding, calcium aluminate cement and distilled water were mixed with the lunar soil to fabricate test specimens. The test specimens consisted of a 1-in cube, a 1/2-in cube, and three 0.12 x 0.58 x 3.15-in beam specimens. Tests were performed on these specimens to determine compressive strength, modulus of rupture, modulus of elasticity, and thermal coefficient of expansion. Based on examination of the material and test results, it is concluded that lunar soil can be used as a fine aggregate for concrete.
NASA Technical Reports Server (NTRS)
Murri, Gretchen Bostaph; Martin, Roderick H.
1991-01-01
Static and fatigue double-cantilever beam (DCB) and end-notch flexure (ENF) tests were conducted to determine the effect of the simulated initial delamination in interlaminar fracture toughness, G(sub c), and fatigue fracture threshold, G(sub th). Unidirectional, 24-ply specimens of S2/SP250 glass/epoxy were tested using Kapton inserts of four different thickness - 13, 25, 75, and 130 microns, at the midplane at one end, or with tension or shear precracks, to simulate an initial delamination. To determine G(sub c), the fatigue fracture threshold below which no delamination growth would occur in less than 1 x 10(exp 6) cycles, fatigue tests were conducted by cyclically loading specimens until delamination growth was detected. Consistent values of model 1 fracture toughness, G(sub Ic), were measured from DCB specimens with inserts of thickness 75 microns or thinner, or with shear precracks. The fatigue DCB tests gave similar values of G(sub Ith) for the 13, 25, and 75 microns specimens. Results for the shear precracked specimens were significantly lower that for specimens without precracks. Results for both the static and fatigue ENF tests showed that measured G(IIc) and G(IIth) values decreased with decreasing insert thickness, so that no limiting thickness could be determined. Results for specimens with inserts of 75 microns or thicker were significantly higher than the results for precracked specimens or specimens with 13 or 25 microns inserts.
The Microstructural Response of Granular Soil Under Uniaxial Strain
1993-10-01
under uniaxial strains of up to 10 percent. The material tested was a poorly graded ottowa sand with specimens consisting of either 0.5- or 0.75-mm...microstructural effects in granular material under uniaxial strain of up to 10.0 percent. The relative influence of several microstructural effects (such as...uniaxial strain. The confinement vessel consisted of a base plate, four walls, and a loading cap. The sidewalls extended up beyond the specimen and served
Fatigue Testing of Wing Beam by the Resonance Method
NASA Technical Reports Server (NTRS)
Bleakney, William M
1938-01-01
Preliminary fatigue tests on two aluminum-alloy wing-beam specimens subjected to reversed axial loading are described. The motion used consists in incorporating one or two reciprocating motors in a resonance system of which the specimen is the spring element. A description is given of the reciprocating motors, and of the method of assembling and adjusting the vibrating system. The results indicate that the method is well adapted to fatigue tests of not only uniform wing beams but also wing beams with asymmetrical local reinforcements.
Friction and wear behavior of aluminum and composite airplane skins
NASA Technical Reports Server (NTRS)
Jackson, K. E.
1984-01-01
Friction and wear behavior was determined for small skin specimens under abrasive loading conditions typical of those occurring on the underside of a transport airplane during emergency belly landing. A test apparatus consisting of a standard belt sander provided the sliding surface. Small test specimens constructed of aluminum, standard graphite-epoxy composite, aramid-epoxy composite, and toughened-resin composites were tested undar a range of pressures, belt velocities, and belt-surface textures. The effects of these test variables on the wear rate and the coefficient of friction are discussed and comparisons are made between the composite materials and aluminum. The effect of fiber orientation in the composite materials on wear rate was also investigated. In addition, tests were performed in which thermocouples were imbedded into the various test specimens to obtain temperature-time histories during abrasion.
DOT National Transportation Integrated Search
1970-12-01
The study was broken down into two phases. Phase I consisted of a laboratory investigation of test specimens to determine the reliability of the ultrasonic equipment and testing procedure. Phase II was a field study where the knowledge, skills and ab...
NASA Technical Reports Server (NTRS)
Stevens, N. J.; Berkopec, F. D.; Blech, R. A.
1976-01-01
The NASA/USAF program on the Environmental Charging of Spacecraft Surfaces consists, in part, of experimental efforts directed toward evaluating the response of materials to the environmental charged particle flux. Samples of thermal blankets of the type to be used on the Global Positioning System Flight Space Vehicles were tested to determine their response to electron flux. The primary result observed was that no discharges were obtained with the quartz-fiber-fabric-covered multilayer insulation specimen. The taped aluminized polyester grounding system used on all specimens did not appear to grossly deteriorate with time; however, the specimens require specific external pressure to maintain constant grounding system resistance.
NASA Technical Reports Server (NTRS)
Creagh, J. W. R.; Smith, J. R.
1973-01-01
Uranium carbide fueled, thermionic emitter configurations were encapsulated and irradiated. One capsule contained a specimen clad with fluoride derived chemically vapor deposited (CVD) tungsten. The other capsule used a duplex clad specimen consisting of chloride derived on floride derived CVD tungsten. Both fuel pins were 16 millimeters in diameter and contained a 45.7-millimeter length of fuel.
Double Cantilever Beam and End Notched Flexure Fracture Toughness Testing of Two Composite Materials
NASA Technical Reports Server (NTRS)
Kessler, Jeff A.; Adams, Donald F.
1993-01-01
Two different unidirectional composite materials were provided by NASA Langley Research Center and tested by the Composite Materials Research Group within the Department of Mechanical Engineering at the University of Wyoming. Double cantilever beam and end notched flexure tests were performed to measure the mode I (crack opening) and mode II (sliding or shear) interlaminar fracture toughness of the two materials. The two composites consisted of IM7 carbon fiber combined with either RP46 resin toughened with special formulation of LaRC IA resin, known as JJS1356; or PES chain extended thermoplastic resin known as JJS1361. Double Cantilever Beam Specimen Configuration and Test Methods As received from NASA, the test specimens were nominally 0.5 inch wide, 6 inches long, and 0.2 inch thick. A 1 inch long Kapton insert at the midplane of one end of the specimen (placed during laminate fabrication) facilitated crack initiation and extension. It was noted that the specimens provided were smaller than the nominal 1.5 inch wide, 9.0 inch long configuration specified. Similarly, the Kapton inserts were of greater length than those in the present specimens. Hence, the data below should not be compared directly to those generated with the referenced methods. No preconditioning was performed on the specimens prior to testing. In general, the methodology was used for the present work. Crack opening loads were introduced to the specimens via piano hinges attached to the main specimen faces at a single end of each specimen. Hinges were bolted to the specimens using the technique presented. The cracks were extended a small distance from the end of the Kapton insert prior to testing. Just before precracking, the sides of the specimens were coated with water-soluble typewriter correction fluid to aid in crack visualization. Scribe marks were then made in the coating at half-inch intervals.
Crack sealer fill characteristics.
DOT National Transportation Integrated Search
2010-06-01
Laboratory testing was conducted to determine the extent of crack fill for crack sealers composed of methyl methacrylate, : epoxy, urethane, and high molecular weight methacrylate. The test specimens consisted of eight-inch long concrete : cylinders ...
Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato
2012-09-01
We compared the ECLusys Anti-HCV (ECL) reagent to the Lumipulse f (LPf) and HISCL (HIS) HCV assays. In a correlation test using 210 routine clinical specimens measured using the Lumipulse method (96 positive and 114 negative), most of the results were consistent for all specimens. In a dilution sensitivity test using three different routine positive specimens, the ECL assay enabled detection at higher levels of sensitivity than either the LPf or the HIS assay. Moreover, when the distribution of the cut-off index (C.O.I.) values of the routine LPf negative specimens were compared to those on the ECL and HIS assays, it was found that on the ECL assay, most of the specimens had cut-off index values < 0.1, indicating a more clear-cut distribution. In a specificity test using high RF positive specimens(n = 33), pregnancy specimens (n = 35), cytomegalovirus (CMV) antibody positive specimens (n = 36), and high M protein positive specimens (n = 21), the ECL assay yielded positive results for a CMV antibody positive specimen and three high M protein positive specimens. Further testing using samples from the same patients collected on different days than these four samples resulted in a second positive result for the CMV positive specimen, and single antigen measurement yielded a Core/NS3 positive result, as well, suggesting past infection. However, since negative results were obtained for the three M protein positive specimens, the possibility of this being a ECLusys non-specific reaction could not be ruled out. The above results confirmed that the ECL assay provides superior fundamental performance, and possesses test performance nearly identical to that of the existing measurement methods that are widely used at a large number of facilities, and would therefore be a suitable assay for use in routine HCV antibody screening.
Mechanical Properties of Degraded PMR-15 Resin
NASA Technical Reports Server (NTRS)
Tsuji, Luis C.; McManus, Hugh L.; Bowles, Kenneth J.
1998-01-01
Thermo-oxidative aging produces a non-uniform degradation state in PMR-15 resin. A surface layer, usually attributed to oxidative degradation, forms. This surface layer has different properties from the inner material. A set of material tests was designed to separate the properties of the oxidized surface layer from the properties of interior material. Test specimens were aged at 316 C in either air or nitrogen, for durations of up to 800 hours. The thickness of the oxidized surface layer in air aged specimens, and the shrinkage and Coefficient of Thermal Expansion (CTE) of nitrogen aged specimens were measured directly. Four-point-bend tests were performed to determine modulus of both the oxidized surface layer and the interior material. Bimaterial strip specimens consisting of oxidized surface material and unoxidized interior material were constructed and used to determine surface layer shrinkage and CTE. Results confirm that the surface layer and core materials have substantially different properties.
Deducing material quality in cast and hot-forged steels by new bending test
NASA Astrophysics Data System (ADS)
Valberg, Henry; Langøy, Morten; Nedreberg, Mette; Helvig, Torgeir
2017-10-01
A special bend test has been developed and applied for the purpose of characterization and comparison of the material ductility in crankpin steel discs manufactured by casting, or casting subsequently followed by hot open-die forging (ODF) or closed-die forging (CDF). The bending test specimen consists of a small rectangular plate of material with a round hole cut out in the middle. The "eye-shape" specimens were cut out from various positions either near to the surface of, or from the interior of the discs. The test method revealed differences in ductility for the investigated materials, and for different depth positions inside the discs. The roughening of the specimen surface on the top-side of the specimen bend also varied dependent on the processing method for the material. Current results show that this test method is useful for evaluation of material quality in differently processed material. Experimental bend test results are presented for differently processed variants of the same material, i.e., crankpin discs either made by solely casting or casting subsequently followed by hot working either by ODF or CDF.
Translucency of zirconia-based pressable ceramics with different core and veneer thicknesses.
Jeong, Il-Do; Bae, So-Yeon; Kim, Dong-Yeon; Kim, Ji-Hwan; Kim, Woong-Chul
2016-06-01
Little information is available on the translucency of zirconia-based pressable ceramic restorations with a pressed ceramic veneer and zirconia core in various thickness combinations. The purpose of this in vitro study was to assess the translucency of 3 types of zirconia-based pressable ceramics for different core-veneer thickness combinations. A bilayered ceramic specimen was prepared with a pressable ceramic (IPS e.max Zirpress, Initial IQ, Rosetta UltraPress) veneer over a zirconia core (Zenostar Zr). Three groups of specimens (n=7) were formed with the following core+veneer thicknesses: 1 +0.5 mm, 0.7 +0.8 mm, and 0.5 +1 mm. To obtain consistent thickness and high translucency, all specimens were subjected to surface grinding with a grinding machine. To eliminate the effect of differences in roughness on the translucency, the surface roughness of the ground specimens was measured with a scanning profiler, and the consistency of these measured values was verified through statistical analysis. The luminous transmittance of the specimens was measured with a spectrophotometer. The effects of the pressable ceramic type and core-veneer thickness combination on transmittance were assessed using a 2-way ANOVA (α=.05). The consistency of the surface roughness among the tested specimens was confirmed using a 1-way ANOVA and the Tukey HSD post hoc test (P<.05). The luminous transmittance exhibited a statistically significant dependence on both the type of pressable ceramic and the core-veneer thickness combination (P<.05). The type of pressable ceramic and core-veneer thickness combination affected the translucency of the restoration. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Nonlinear fracture of concrete and ceramics
NASA Technical Reports Server (NTRS)
Kobayashi, Albert S.; Du, Jia-Ji; Hawkins, Niel M.; Bradt, Richard C.
1989-01-01
The nonlinear fracture process zones in an impacted unnotched concrete bend specimen, a prenotched ceramic bend specimen, and an unnotched ceramic/ceramic composite bend specimen were estimated through hybrid experimental numerical analysis. Aggregate bridging in concrete, particulate bridging in ceramics, and fiber bridging in ceramic/ceramic composite are modeled by Barenblatt-type cohesive zones which are incorporated into the finite-element models of the bend specimens. Both generation and propagation analyses are used to estimate the distribution of crack closure stresses in the nonlinear fracture process zones. The finite-element models are then used to simulate fracture tests consisting of rapid crack propagation in an impacted concrete bend specimen, and stable crack growth and strain softening in a ceramic and ceramic/ceramic composite bend specimens.
Simamoto Júnior, Paulo Cézar; Resende Novais, Veridiana; Rodrigues Machado, Asbel; Soares, Carlos José; Araújo Raposo, Luís Henrique
2015-05-01
Framework longevity is a key factor for the success of complete-arch prostheses and commonly depends on the welding methods. However, no consensus has been reached on the joint design and welding type for improving framework resistance. The purpose of this study was to assess the effect of different joint designs and welding methods with tungsten inert gas (TIG) or laser to join titanium alloy bars (Ti-6Al-4V). Seventy titanium alloy bar specimens were prepared (3.18 mm in diameter × 40.0 mm in length) and divided into 7 groups (n=10): the C-control group consisting of intact specimens without joints and the remaining 6 groups consisting of specimens sectioned perpendicular to the long-axis and rejoined using an I-, X30-, or X45-shaped joint design with TIG welding (TI, TX30, and TX45) or laser welding (LI, LX30, and LX45). The specimens were tested with 3-point bending. The fracture surfaces were first evaluated with stereomicroscopy to measure the weld penetration area and then analyzed with scanning electron microscopy (SEM). The data were statistically analyzed with 2-way ANOVA and the Tukey post hoc test, 1-way ANOVA and the Dunnett test, and the Pearson correlation test (α=.05). Specimens from the X30 and X45 groups showed higher flexural strength (P<.05) and welded area (P<.05) than specimens from the I groups, regardless of the welding type. TIG welded groups showed significantly higher flexural strength than the laser groups (P<.05), regardless of the joint design. TIG welding also resulted in higher welded areas than laser welding for the I-shaped specimens. No significant differences were found for the weld penetration area in the X45 group, either for laser or TIG welding. SEM analysis showed more pores at the fracture surfaces of the laser specimens. Fracture surfaces indicative of regions of increased ductility were detected for the TIG specimens. TIG welding resulted in higher flexural strength for the joined titanium specimens than laser welding. For both welding methods, X30- and X45-shaped joint designs resulted in higher flexural strength and welding penetration than the I-shaped joint design. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Unger, Jakob; Merhof, Dorit; Renner, Susanne
2016-11-16
Global Plants, a collaborative between JSTOR and some 300 herbaria, now contains about 2.48 million high-resolution images of plant specimens, a number that continues to grow, and collections that are digitizing their specimens at high resolution are allocating considerable recourses to the maintenance of computer hardware (e.g., servers) and to acquiring digital storage space. We here apply machine learning, specifically the training of a Support-Vector-Machine, to classify specimen images into categories, ideally at the species level, using the 26 most common tree species in Germany as a test case. We designed an analysis pipeline and classification system consisting of segmentation, normalization, feature extraction, and classification steps and evaluated the system in two test sets, one with 26 species, the other with 17, in each case using 10 images per species of plants collected between 1820 and 1995, which simulates the empirical situation that most named species are represented in herbaria and databases, such as JSTOR, by few specimens. We achieved 73.21% accuracy of species assignments in the larger test set, and 84.88% in the smaller test set. The results of this first application of a computer vision algorithm trained on images of herbarium specimens shows that despite the problem of overlapping leaves, leaf-architectural features can be used to categorize specimens to species with good accuracy. Computer vision is poised to play a significant role in future rapid identification at least for frequently collected genera or species in the European flora.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nanstad, Randy K; Sokolov, Mikhail A; Merkle, John Graham
2007-01-01
To enable determination of the fracture toughness reference temperature, T0, with reactor pressure vessel surveillance specimens, the precracked Charpy (PCVN) three-point bend, SE(B), specimen is of interest. Compared with the 25-mm (1 in.) thick compact, 1TC(T), specimen, tests with the PCVN specimen (10x10x55 mm) have resulted in T0 temperatures as much as 40 XC lower (a so-called specimen bias effect). The Heavy-Section Steel Irradiation (HSSI) Program at Oak Ridge National Laboratory developed a two-part project to evaluate the C(T) versus PCVN differences, (1) calibration experiments concentrating on test practices, and (2) a matrix of transition range tests with various specimenmore » geometries and sizes, including 1T SE(B) and 1TC(T). The test material selected was a plate of A533 grade B class 1 steel. The calibration experiments included assessment of the computational validity of J-integral determinations, while the constraint characteristics of various specimen types and sizes were evaluated using key curves and notch strength determinations. The results indicate that J-integral solutions for the small PCVN specimen are comparable in terms of J-integral validity with 1T bend specimens. Regarding constraint evaluations, Phase I deformation is defined where plastic deformation is confined to crack tip plastic zone development, whereas Phase II deformation is defined where plastic hinging deformation develops. In Phase II deformation, the 0.5T SE(B) B B specimen (slightly larger than the PCVN specimen) consistently showed the highest constraint of all SE(B) specimens evaluated for constraint comparisons. The PCVN specimen begins the Phase II type of deformation at relatively low KR levels, with the result that KJc values above about 70 MPa m from precracked Charpy specimens are under extensive plastic hinging deformation.« less
NASA Astrophysics Data System (ADS)
Pesin, A.; Pustovoytov, D.; Lokotunina, N.
2017-12-01
The mechanism of severe plastic deformation comes from very significant shear strain. Shear-compression testing of materials is complicated by the fact that a state of large equivalent strain with dominant shear strain is not easily achievable. This paper presents the novel technique of laboratory simulation of severe plastic deformation by multi-cycle shear-compression testing at room temperature with equivalent strain e=1…5. The specimen consisted of a parallelepiped having an inclined gauge section created by two diametrically opposed semi-circular slots which were machined at 45°. Height of the specimen was 50 mm, section dimensions were 25×25 mm, gauge thickness was 5.0 mm and gauge width was 6.0 mm. The specimen provided dominant shear strain in an inclined gauge-section. The level of shear strain and equivalent strain was controlled through adjustment of the height reduction of the specimen, load application direction and number of cycles of shear-compression. Aluminium alloy Al-6.2Mg-0.7Mn was used as a material for specimen. FE simulation and analysis of the stress-strain state were performed. The microstructure of the specimen after multi-cycle shear-compression testing with equivalent strain e=1…5 was examined by optical and scanning electron microscope.
Development of U-frame bending system for studying the vibration integrity of spent nuclear fuel
NASA Astrophysics Data System (ADS)
Wang, Hong; Wang, Jy-An John; Tan, Ting; Jiang, Hao; Cox, Thomas S.; Howard, Rob L.; Bevard, Bruce B.; Flanagan, Michelle
2013-09-01
A bending fatigue system developed to evaluate the response of spent nuclear fuel rods to vibration loads is presented. A U-frame testing setup is used for imposing bending loads on the fuel rod specimen. The U-frame setup consists of two rigid arms, side connecting plates to the rigid arms, and linkages to a universal testing machine. The test specimen's curvature is obtained through a three-point deflection measurement method. The tests using surrogate specimens with stainless steel cladding revealed increased flexural rigidity under unidirectional cyclic bending, significant effect of cladding-pellets bonding on the response of surrogate rods, and substantial cyclic softening in reverse bending mode. These phenomena may cast light on the expected response of a spent nuclear fuel rod. The developed U-frame system is thus verified and demonstrated to be ready for further pursuit in hot-cell tests.
NASA Technical Reports Server (NTRS)
Larsson, S. E.
1972-01-01
A part of the lower side of the main wing at the joint of the main spar with the fuselage frame was investigated. This wing beam area was simulated by a test specimen consisting of a spar boom of AZ 74 forging (7075 aluminum alloy modified with 0.3 percent Ag) and a portion of a honeycomb sandwich panel attached to the boom flange with steel bolts. The cross section was reduced to half scale. However, the flange thickness, the panel height, and the bolt size were full scale. Further, left and right portions of the fuselage frame intended to carry over the bending moment of the main wing were tested. Each of these frame halves consisted of a forward and a rear forging (7079 aluminum alloy, overaged) connected by an outer and inner skin (Alclad 7075) creating a box beam. These test specimens were full scale and were constructed principally of ordinary aircraft components. The test load spectrum was common to both types of specimens with regard to percentage levels. It consisted of maneuver and gust loads, touchdown loads, and loads due to ground roughness. A load history of 200 hours of flight with 15,000 load cycles was punched on a tape. The loads were randomized in groups according to the flight-by-flight principle. The highest positive load level was 90 percent of limit load and the largest negative load was -27 percent. A total of 20 load levels were used. Both types of specimens were provided with strain gages and had a nominal stress of about 300 MN/sq m in some local areas. As a result of the tests, steps were taken to reduce the risk of fatigue damage in aircraft. Thus stress levels were lowered, radii were increased, and demands on surface finish were sharpened.
Oxidation behavior of a thermal barrier coating
NASA Technical Reports Server (NTRS)
Miller, R. A.
1984-01-01
Thermal barrier coatings, consisting of a plasma sprayed calcium silicate ceramic layer and a CoCrAlY or NiCrAlY bond coat, were applied on B-1900 coupons and cycled hourly in air in a rapid-response furnace to maximum temperatures of 1030, 1100, or 1160 C. Eight specimens were tested for each of the six conditions of bond-coat composition and temperature. Specimens were removed from test at the onset of failure, which was taken to be the formation of a fine surface crack visible at 10X magnification. Specimens were weighed periodically, and plots of weight gain vs time indicate that weight is gained at a parabolic rate after an initial period where weight was gained at a much greater rate. The high initial oxidation rate is thought to arise from the initially high surface area in the porous bond coat. Specimen life (time to first crack) was found to be a strong function of temperature. However, while test lives varied greatly with time, the weight gain at the time of specimen failure was quite insensitive to temperature. This indicates that there is a critical weight gain at which the coating fails when subjected to this test.
Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato
2012-02-01
We compared the ECLusys HBsAgII (ECL HBsAg) assay to the Lumipulse Forte (LPf HBsAg) and HISCL (HIS HBsAg) assays. Measurement of dilution panels for which the WHO HBsAg international reference panel was the parent specimen revealed that the ECL and HIS assays enabled detection to a theoretical level of 0.04 IU/mL, whereas the LPf assay enabled detection to a level of 0.08 IU/mL. In a specificity test using high RF positive specimens (n = 33), pregnancy specimens (n = 35), cytomegalovirus antibody positive specimens (n = 36), and high M protein positive specimens (n = 21) that were confirmed negative for HBsAg by the LPf assay, negative results were obtained for all specimens on the HIS assay, but the ECL assay yielded a positive result for one of the high RF positive specimens. This individual was suggested on further testing to be an HBV carrier who was strongly positive for HBc antibody. In HBsAg mutants detection test, the detection rate was 92.3% with the ECL assay and 69.2% with the HIS assay. In a correlation test using routinely collected clinical specimens (n = 155), including positive stock specimens, aside from the one case where the LPf assay gave a negative result but both the ECL and HIS assays gave positive results, all of the results were consistent for all specimens. The above results confirmed that the ECL assay is both highly sensitive and specific, and also enables a high rate of HBsAg mutant detection.
Tensile and compressive stress-strain behavior of heat treated boron-aluminum
NASA Technical Reports Server (NTRS)
Kennedy, J. M.; Tenney, D. R.; Herakovich, C. T.
1978-01-01
An experimental study was conducted to assess the effects of heat treatment and cyclic mechanical loading on the tensile and compressive stress-strain behavior of six boron-aluminum composites having different laminate orientations and being subjected to different heat treatments. The heat treatments were as-fabricated, T6, and T6N consisting of T6 treatment followed by cryogenic quench in liquid nitrogen prior to testing. All laminates were tested in monotonic and cyclic compression, while the tensile-test data are taken from the literature for comparison purposes. It is shown that the linear elastic range of the T6- and T6N-condition specimens is larger than that of the as-fabricated specimens, and that cyclic loading in tension or compression strain hardens the specimens and extends the linear elastic range. For laminates containing 0-deg plies, the stress-strain behavior upon unloading is found to be nonlinear, whereas the other laminates exhibit a linear behavior upon unloading. Specimens in the T6 and T6N conditions show higher strain hardening than the as-fabricated specimens.
Investigation of Tensile Creep of a Normal Strength Overlay Concrete.
Drexel, Martin; Theiner, Yvonne; Hofstetter, Günter
2018-06-12
The present contribution deals with the experimental investigation of the time-dependent behavior of a typical overlay concrete subjected to tensile stresses. The latter develop in concrete overlays, which are placed on existing concrete structures as a strengthening measure, due to the shrinkage of the young overlay concrete, which is restrained by the substrate concrete. Since the tensile stresses are reduced by creep, creep in tension is investigated on sealed and unsealed specimens, loaded at different concrete ages. The creep tests as well as the companion shrinkage tests are performed in a climatic chamber at constant temperature and constant relative humidity. Since shrinkage depends on the change of moisture content, the evolution of the mass water content is determined at the center of each specimen by means of an electrolytic resistivity-based system. Together with the experimental results for compressive creep from a previous study, a consistent set of time-dependent material data, determined for the same composition of the concrete mixture and on identical specimens, is now available. It consists of the hygral and mechanical properties, creep and shrinkage strains for both sealed and drying conditions, the respective compliance functions, and the mass water contents in sealed and unsealed, loaded and load-free specimens.
Automated Plasma Spray (APS) process feasibility study
NASA Technical Reports Server (NTRS)
Fetheroff, C. W.; Derkacs, T.; Matay, I. M.
1981-01-01
An automated plasma spray (APS) process was developed to apply two layer (NiCrAlY and ZrO2-12Y2O3) thermal barrier coatings to aircraft and stationary gas turbine engine blade airfoils. The APS process hardware consists of four subsystems: a mechanical positioning subsystem incorporating two interlaced six degree of freedom assemblies (one for coating deposition and one for coating thickness monitoring); a noncoherent optical metrology subsystem (for in process gaging of the coating thickness buildup at specified points on the specimen); a microprocessor based adaptive system controller (to achieve the desired overall thickness profile on the specimen); and commerical plasma spray equipment. Over fifty JT9D first stage aircraft turbine blade specimens, ten W501B utility turbine blade specimens and dozens of cylindrical specimens were coated with the APS process in preliminary checkout and evaluation studies. The best of the preliminary turbine blade specimens achieved an overall coating thickness uniformity of 53 micrometers (2.1 mils), much better than is achievable manually. Comparative evaluations of coating thickness uniformity for manually sprayed and APS coated specimens were performed. One of the preliminary turbine blade evaluation specimens was subjected to a torch test and metallographic evaluation. Some cylindrical specimens coated with the APS process survived up to 2000 cycles in subsequent burner rig testing.
A Test for Characterizing Delamination Migration in Carbon/Epoxy Tape Laminates
NASA Technical Reports Server (NTRS)
Ratcliffe, James G.; Czabaj, Michael W.; O'Brien, Thomas K.
2013-01-01
A new test method is presented for the purpose of investigating migration of a delamination between neighboring ply interfaces in fiber-reinforced, polymer matrix tape laminates. The test is a single cantilever beam configuration consisting of a cross-ply laminate with a polytetrafluoroethylene insert implanted at the mid-plane and spanning part way along the length of the specimen. The insert is located between a 0- degree ply (specimen length direction) and a stack of four 90-degree plies (specimen width direction). The specimen is clamped at both ends onto a rigid baseplate and is loaded on its upper surface via a piano hinge. Tests were conducted with the load-application point located on the intact portion of the specimen in order to initiate delamination growth onset followed by migration of the delamination to a neighboring 90/0 ply interface by kinking through the 90-degree ply stack. Varying this position was found to affect the distance relative to the load-application point at which migration initiated. In each specimen, migration initiated by a gradual transition of the delamination at the 0/90 interface into the 90-degree ply stack. In contrast, transition of the kinked crack into the 90/0 interface was sudden. Fractography of the specimens indicated that delamination prior to migration was generally mixed mode-I/II. Inspection of the kink surface revealed mode-I fracture. In general, use of this test allows for the observation of the growth of a delamination followed by migration of the delamination to another ply interface, and should thus provide a means for validating analyses aimed at simulating migration.
Maintenance coating of weathering steel : field evaluation and guidelines
DOT National Transportation Integrated Search
1995-03-01
This report describes a 4-year bridge and test fence evaluation of protective coatings for maintaining weathering steel bridges. The test specimens consisted of steel panels cut from existing aged weathering steel bridges, along with some new mill sc...
NASA Technical Reports Server (NTRS)
Peck, Ann W.
1998-01-01
As composites are introduced into more complex structures with out-of-plane loadings, a better understanding is needed of the out-of-plane, matrix-dominated failure mechanisms. This work investigates the transverse tension fatigue characteristics of IM6/3501 composite materials. To test the 90 degree laminae, a three-point bend test was chosen, potentially minimizing handling and gripping issues associated with tension tests. A finite element analysis was performed of a particular specimen configuration to investigate the influence of specimen size on the stress distribution for a three-point bend test. Static testing of 50 specimens of 9 different sized configurations produced a mean transverse tensile strength of 61.3 Mpa (8.0 ksi). The smallest configuration (10.2 mm wide, Span-to-thickness ratio of 3) consistently exhibited transverse tensile failures. A volume scale effect was difficult to discern due to the large scatter of the data. Static testing of 10 different specimens taken from a second panel produced a mean transverse tensile strength of 82.7 Mpa (12.0 ksi). Weibull parameterization of the data was possible, but due to variability in raw material and/or manufacturing, more replicates are needed for greater confidence. Three-point flex fatigue testing of the smallest configuration was performed on 59 specimens at various levels of the mean static transverse tensile strength using an R ratio of 0.1 and a frequency of 20 Hz. A great deal of scatter was seen in the data. The majority of specimens failed near the center loading roller. To determine whether the scatter in the fatigue data is due to variability in raw material and/or the manufacturing process, additional testing should be performed on panels manufactured from different sources.
NASA Astrophysics Data System (ADS)
Alejos, Martin Fernando
Additive manufacturing has become a highly researched topic in recent years all over the world. The current research evaluates the merits of additive manufacturing based on the mechanical, microstructural, and fracture properties of additive manufactured AlSi10Mg test specimens. The additive manufactured build plates consisted of tensile and fatigue test specimens. They were printed in the 0°, 30°, 60°, and 90° orientations relative to the build platform. Tensile and dynamic fatigue tests were conducted followed by microstructural characterization and fracture analysis. A wrought 6061 T6 aluminum alloy was also tested for comparison. Tensile tests revealed similar ultimate tensile strengths for all aluminum tensile specimens (350-380 MPa). Fatigue strength was greatest for wrought 6061 T6 aluminum (175 MPa). The fatigue behavior was a strong function of build orientation for the additive manufactured specimens. The 0°, 30°, and 60° orientations had fatigue strengths close to 104 MPa while the 90° orientation had a fatigue strength of 125 MPa. All test specimens failed primarily in a ductile manner. The effect of laser power, hatch spacing, and scan speed were also studied using microstructural analysis. Increasing laser power decreased grain size and void size. Increasing scan speed led to the formation of columnar grains. Increasing hatch spacing decreased grain size and the amount of voids present in the microstructure.
End Restraints for Impact-Energy-Absorbing Tube Specimens
NASA Technical Reports Server (NTRS)
Farley, G. L.; Modlin, J. T.
1985-01-01
Inexpensive device developed that eliminates tipping problem without affecting crushing process. Device consists of soft sponge-rubber insert approximately 0.5 inches (1.3 centimeters) thick, cut to same diameter as internal diameter of tube specimen. Metal washer, slightly smaller than internal diameter of tube, placed on top of rubber insert. Screw passed through washer and rubber insert and threaded into base of test machine. As screw tightened against washer, rubber insert compressed and expands radially. Radial expansion applies pressure against internal wall of tube specimen, which provides sufficient support to tube to prevent tipping.
Creep rupture testing of alloy 617 and A508/533 base metals and weldments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Natesan, K.; Li, M.; Soppet, W.K.
2012-01-17
The NGNP, which is an advanced HTGR concept with emphasis on both electricity and hydrogen production, involves helium as the coolant and a closed-cycle gas turbine for power generation with a core outlet/gas turbine inlet temperature of 750-1000 C. Alloy 617 is a prime candidate for VHTR structural components such as reactor internals, piping, and heat exchangers in view of its resistance to oxidation and elevated temperature strength. However, lack of adequate data on the performance of the alloy in welded condition prompted to initiate a creep test program at Argonne National Laboratory. In addition, Testing has been initiated tomore » evaluate the creep rupture properties of the pressure vessel steel A508/533 in air and in helium environments. The program, which began in December 2009, was certified for quality assurance NQA-1 requirements during January and February 2010. Specimens were designed and fabricated during March and the tests were initiated in April 2010. During the past year, several creep tests were conducted in air on Alloy 617 base metal and weldment specimens at temperatures of 750, 850, and 950 C. Idaho National Laboratory, using gas tungsten arc welding method with Alloy 617 weld wire, fabricated the weldment specimens. Eight tests were conducted on Alloy 617 base metal specimens and nine were on Alloy 617 weldments. The creep rupture times for the base alloy and weldment tests were up to {approx}3900 and {approx}4500 h, respectively. The results showed that the creep rupture lives of weld specimens are much longer than those for the base alloy, when tested under identical test conditions. The test results also showed that the creep strain at fracture is in the range of 7-18% for weldment samples and were much lower than those for the base alloy, under similar test conditions. In general, the weldment specimens showed more of a flat or constant creep rate region than the base metal specimens. The base alloy and the weldment exhibited tertiary creep after 50-60% of the rupture life, irrespective of test temperature in the range of 750-950 C. The results showed that the stress dependence of the creep rate followed a power law for both base alloy and weldments. The data also showed that the stress exponent for creep is the same and one can infer that the same mechanism is operative in both base metal and weldments in the temperature range of the current study. SEM fractography analysis indicated that both base metal and weldment showed combined fracture modes consisting of dimple rupture and intergranular cracking. Intergranular cracking was more evident in the weldment specimens, which is consistent with the observation of lower creep ductility in the weldment than in the base metal.« less
Evaluation of flexural, diametral tensile, and shear bond strength of composite repairs.
Imbery, T A; Gray, T; DeLatour, F; Boxx, C; Best, A M; Moon, P C
2014-01-01
Repairing composite restorations may be a more conservative treatment than replacing the entire restoration. The objective of this in vitro study was to determine the best repair method by measuring flexural, diametral tensile, and shear bond strength of repaired composites in which the surfaces were treated with chemical primers (Add & Bond or Silane Bond Enhancer), a bonding agent (Optibond Solo Plus [OBSP]), or mechanical retention with a bonding agent. Filtek Supreme Ultra shade B1B was placed in special molds to fabricate specimens that served to test the flexural, diametral tensile, or shear strength of the inherent resin substrate. The same molds were modified to make specimens for testing repair strength of the resin. Repairs were made immediately or after aging in deionized water at 37°C for seven days. All repair sites were finished with coarse Sof-Lex discs to simulate finishing new restorations or partially removing aged restorations. Repair surfaces were treated with one of the following: 1) phosphoric-acid etching and OBSP; 2) Add & Bond; 3) phosphoric-acid etching, Silane Bond Enhancer, and OBSP; or 4) quarter round bur, phosphoric-acid etching, and OBSP. Specimens were placed back in the original molds to fabricate specimens for diametral tensile or flexural testing or in an Ultradent jig to make specimens for shear bond testing. Composite resin in shade B5B was polymerized against the treated surfaces to make repairs. Two negative control groups for the three testing methods consisted of specimens in which repairs were made immediately or after aging without any surface treatments. Controls and experimental repairs were aged (water 37°C, 24 hours) before flexural, diametral tensile, or shear testing in an Instron Universal testing machine at a crosshead speed of 0.5 mm/min. Experimental flexural repair strengths ranged from 26.4% to 88.6% of the inherent substrate strength. Diametral tensile repair strengths ranged from 40% to 80% of the inherent substrate strength, and shear bond strength repairs ranged from 56% to 102%. Geometric means were statistically analyzed with two-way analysis of variance on their log-transformed values. Significant differences were determined using Tukey honestly significant difference (p<0.05). Depending on the mechanical property being tested, surface treatments produced different results. OBSP produced more consistent results than chemical primers.
Garoushi, Sufyan K; Lassila, Lippo V J; Tezvergil, Arzu; Vallittu, Pekka K
2006-09-01
The aim of this study was to determine the static load-bearing capacity of composite resin onlay restorations made of particulate filler composite (PFC) with two different types of fiber-reinforced composite (FRC) substructures. In addition, flexural properties of the material combination and the effect of polymerization devices were tested. Specimens were prepared to simulate an onlay restoration, which consisted of 2 to 3 mm of FRC layer as a substructure (short random and continuous bidirectional fiber orientation) and a 1 mm surface layer of PFC. Control specimens were prepared from plain PFC. In Group A the specimens were incrementally polymerized only with a hand-light curing unit for 40 s, while in Group B the specimens were post-cured in a light-curing oven for 15 min before they were statically loaded with a steel ball. Bar-shaped test specimens were prepared to measure the flexural properties of material combination using a three-point bending test (ISO 10477). Analysis of variance (ANOVA) revealed all specimens with a FRC substructure have higher values of static load-bearing capacity and flexural properties than those obtained with plain PFC (p<0.001). The load-bearing capacity of all the specimens decreased after post-curing and water storage. Restorations made from a material combination of FRC and PFC showed better mechanical properties than those obtained with plain PFC.
NASA Astrophysics Data System (ADS)
Calvetti, Francesco; Cardani, Giuliana; Meda, Alberto
1999-09-01
The cultural heritage of many nations consist of a great variety of structures of high intrinsic value, which are often composed of natural building stones (NBS), as granite, limestone, marble and sandstone. The use of accurate inspection devices, such as laser interferometry, allows us to acquire information regarding the mechanical properties and damage (tensile cracks) of NBS, which represents the first step in the restoration process. In this paper, the potential application of an electronic speckle pattern interferometry (ESPI) is shown, with particular attention to the observed displacement field and the crack penetration during laboratory testing. In ESPI, by superimposing a reflected light to a reference digitized image, an interference phenomenon is produced. By comparing two recorded interference patterns (before and after loading), the corresponding deformation can be evaluated. The application of ESPI in several laboratory tests on NBS is presented in this paper. In particular, during bending tests performed on geometrically similar NBS specimens, it was observed that the size and shape of the localized damage zone do not depend on the specimen size. These results allow for an interpretation of the 'size- effect,' which consists of a reduction of nominal strength as the specimen size increases.
Yin, Yue-Ping; Wei, Wan-Hui; Wang, Hong-Chun; Zhu, Bang-Yong; Yu, Yan-Hua; Chen, Xiang-Sheng; Peeling, Rosanna W; Cohen, Myron S
2009-03-01
China is experiencing a growing syphilis epidemic. Individuals are currently screened and cases are confirmed using traditional serological testing methods. A total of 11 558 serum specimens from patients at 14 sexually transmitted diseases (STD) clinics at provincial, prefecture and county levels in Guangxi Autonomous Region were tested at local clinics using the toluidine red unheated serum test (TRUST) and the SD Bioline Syphilis 3.0 Treponema Pallidum (SD-TP) test and then transported to the National STD Reference Laboratory for TRUST and confirmatory Treponema pallidum particle assay (TPPA) testing. In local clinics, 13.2% of specimens were TRUST positive and 12.8% were TRUST and SD-TP positive. At the Reference Laboratory, 15.4% of specimens were TRUST positive and 11.8% were TRUST and TPPA positive. Local clinics showed a significantly higher prevalence of active syphilis compared with results from the Reference Laboratory (12.8 v. 11.8%, chi(2) = 4.59, P = 0.03). The local TRUST tests had consistent results with Reference Laboratory tests qualitatively among 96.2% of the specimens and quantitatively among 95.5% of the specimens. The algorithm of TRUST screening and then SD-TP confirmation among positive TRUST specimens at local STD clinics had 96.6% sensitivity and 99.3% specificity in diagnosing active syphilis compared with the 'gold standard' based on TRUST and TPPA positivity at the Reference Laboratory (positive predictive value 95.1% and negative predictive value 99.5%). The TRUST screening and SD-TP confirmation in combination can be used at local STD clinics for the efficient diagnosis of serologically active syphilis. However, continuing capacity building and quality assurance remain critical in ensuring the quality of syphilis diagnosis at local clinics.
De Ryck, R; Struelens, M J; Serruys, E
1994-01-01
Four screens for the rapid (4 to 6 h) biochemical detection of pathogens from enteric isolation media are described. The Salmonella screen consisted of Kligler iron agar (KIA), motility-indole-urea-tryptophan-deamination semisolid medium (MIU-TDA), and the o-nitrophenyl-beta-D-galactopyranoside (ONPG) test; the Shigella screen consisted of KIA, MIU-TDA, the ONPG test, and the lysine decarboxylation-indole test; the Yersinia screen consisted of a rhamnose broth; the Aeromonas screen consisted of a xylose agar plate. When tested on 2,102 fresh isolates and 71 stock strains, the screens correctly detected 212 enteric pathogens (sensitivity, 100%), with a specificity of 98.1%. PMID:8077408
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singh, Gyanender P.; Gonczy, Steve T.; Deck, Christian P.
An interlaboratory round robin study was conducted on the tensile strength of SiC–SiC ceramic matrix composite (CMC) tubular test specimens at room temperature with the objective of expanding the database of mechanical properties of nuclear grade SiC–SiC and establishing the precision and bias statement for standard test method ASTM C1773. The mechanical properties statistics from the round robin study and the precision statistics and precision statement are presented herein. The data show reasonable consistency across the laboratories, indicating that the current C1773–13 ASTM standard is adequate for testing ceramic fiber reinforced ceramic matrix composite tubular test specimen. Furthermore, it wasmore » found that the distribution of ultimate tensile strength data was best described with a two–parameter Weibull distribution, while a lognormal distribution provided a good description of the distribution of proportional limit stress data.« less
Singh, Gyanender P.; Gonczy, Steve T.; Deck, Christian P.; ...
2018-04-19
An interlaboratory round robin study was conducted on the tensile strength of SiC–SiC ceramic matrix composite (CMC) tubular test specimens at room temperature with the objective of expanding the database of mechanical properties of nuclear grade SiC–SiC and establishing the precision and bias statement for standard test method ASTM C1773. The mechanical properties statistics from the round robin study and the precision statistics and precision statement are presented herein. The data show reasonable consistency across the laboratories, indicating that the current C1773–13 ASTM standard is adequate for testing ceramic fiber reinforced ceramic matrix composite tubular test specimen. Furthermore, it wasmore » found that the distribution of ultimate tensile strength data was best described with a two–parameter Weibull distribution, while a lognormal distribution provided a good description of the distribution of proportional limit stress data.« less
Modernization of existing VVER-1000 surveillance programs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kochkin, V.; Erak, D.; Makhotin, D.
2011-07-01
According to generally accepted world practice, evaluation of the reactor pressure vessel (RPV) material behavior during operation is carried out using tests of surveillance specimens. The main objective of the surveillance program consists in insurance of safe RPV operation during the design lifetime and lifetime-extension period. At present, the approaches of pressure vessels residual life validation based on the test results of their surveillance specimens have been developed and introduced in Russia and are under consideration in other countries where vodo-vodyanoi energetichesky reactors- (VVER-) 1000 are in operation. In this case, it is necessary to ensure leading irradiation of surveillancemore » specimens (as compared to the pressure vessel wall) and to provide uniformly irradiated specimen groups for mechanical testing. Standard surveillance program of VVER-1000 has several significant shortcomings and does not meet these requirements. Taking into account program of lifetime extension of VVER-1000 operating in Russia, it is necessary to carry out upgrading of the VVER-1000 surveillance program. This paper studies the conditions of a surveillance specimen's irradiation and upgrading of existing sets to provide monitoring and prognosis of RPV material properties for extension of the reactor's lifetime up to 60 years or more. (authors)« less
Lindan, Christina; Mathur, Meenakshi; Kumta, Sameer; Jerajani, Hermangi; Gogate, Alka; Schachter, Julius; Moncada, Jeanne
2005-04-01
Pooling urogenital specimens for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae by nucleic acid amplification tests is an attractive alternative to individual testing. As pooling can reduce the costs of testing as well as labor, it has been advocated for use in resource-poor settings. However, it has neither been widely adopted nor evaluated for use in developing countries. We evaluated the practical use of pooling first-catch urine (FCU) specimens for the detection of C. trachomatis and N. gonorrhoeae from 690 men in Mumbai, India, by PCR. FCU, urethral smears, and swabs were collected from men seen at two sexually transmitted infection (STI) clinics. All laboratory testing was done at the Lokmanya Tilak General Hospital. Gram stain smears and culture isolation for N. gonorrhoeae were performed. Each FCU was tested individually and in pools using the Roche Amplicor PCR for C. trachomatis and N. gonorrhoeae with an internal control for inhibition. Specimen pools consisted of aliquots from five consecutively processed FCUs combined into an amplification tube. An optical density reading of > or =0.20 indicated a pool for which subsequent testing of individual samples was required. Prevalence by PCR on single specimens was 2.2% (15/690) for C. trachomatis and 5.4% (37/690) for N. gonorrhoeae. Compared to individual FCU results, pooling for C. trachomatis and N. gonorrhoeae had an overall sensitivity of 96.1% (50/52). Specificity was 96.5% (83/86) in that three pools required single testing that failed to identify a positive specimen. Pooling missed two positive specimens, decreased the inhibition rate, and saved 50.3% of reagent costs. In this resource-limited setting, the use of pooling to detect C. trachomatis and N. gonorrhoeae by PCR proved to be a simple, accurate, and cost-effective procedure compared to individual testing.
García, Patricia; Balcells, M Elvira; Castillo, Claudia; Miranda, Carolina; Geoffroy, Enrique; Román, Juan C; Wozniak, Aniela
2017-08-01
Extra-pulmonary tuberculosis (TB) represents the 26.2% of total TB cases in Chile. Culture is the gold standard method, but the process is extremely slow. Xpert®MTB/RIF technique detects Mycobacterium tuberculosis complex (MTBc) through real time PCR in less than 3 h. However, it has been validated only for respiratory specimens. We aimed to determine the performance of Xpert®MTB/RIF test in detecting MTBc in extra-respiratory specimens compared with a combined gold standard consisting in a positive (liquid and solid) mycobacterial culture and/or a positive validated molecular method (q-RPC, Cobas®TaqMan®-MTB). Fifty extra-respiratory specimens were analyzed, from which 25 were positive and 25 negative for MTBc based on the combined gold standard. The 25 positive specimens had a positive result by Xpert®MTB/RIF; from the 25 negative specimens, 24 had a negative result and one had a positive result. We obtained an overall concordance of 98% between Xpert®MTB/RIF and the combined gold standard. Xpert®MTB/RIF test was able to detect 12 smear-negative specimens and 3 culture-negative specimens, all of them corresponding to extra-pulmonary TB cases. Xpert®MTB/RIF showed similar sensitivity to q-RPC in detecting MTBc in extra-respiratory specimens. This procedure allowed a substantial reduction in the time of diagnosis.
Bonding capacity of the GFRP-S on strengthened RC beams after sea water immersion
NASA Astrophysics Data System (ADS)
Sultan, Mufti Amir; Djamaluddin, Rudy
2017-11-01
Construction of concrete structures that located in extreme environments are such as coastal areas will result in decreased strength or even the damage of the structures. As well know, chloride contained in sea water is responsible for strength reduction or structure fail were hence maintenance and repairs on concrete structure urgently needed. One popular method of structural improvements which under investigation is to use the material Glass Fibre Reinforced Polymer which has one of the advantages such as corrosion resistance. This research will be conducted experimental studies to investigate the bonding capacity behavior of reinforced concrete beams with reinforcement GFRP-S immersed in sea water using immersion time of one month, three months, six months and twelve months. Test specimen consists of 12 pieces of reinforced concrete beams with dimensions (150x200x3000) mm that had been reinforced with GFRP-S in the area of bending, the beam without immersion (B0), immersion one month (B1), three months (B3), six months (B6) and twelve months (B12). Test specimen were cured for 28 days before the application of the GFRP sheet. Test specimen B1, B3, B6 and B12 that have been immersed in sea water pool with a immersion time each 1, 3, 6 and 12 months. The test specimen without immersion test by providing a static load until it reaches the failure, to record data during the test strain gauge mounted on the surface of the specimen and the GFRP to collect the strain value. From the research it obvious that there is a decrease bonding capacity on specimens immersed for one month, three months, six months and twelve months against the test object without immersion of 8.85%; 8.89%; 9.33% and 11.04%.
Stone, Nelson N; Mouraviev, Vladimir; Schechter, David; Lucia, M Scott; Smith, Elizabeth E; Arangua, Paul; Hoenemeyer, John; Rosa, Jim; Bawa, Rajan; Crawford, E David
2017-09-01
To increase the likelihood of detecting anterior cancers within the prostate and provide a specimen that spans the length of the gland. Newly designed 17- and 15-gauge (G) biopsy needles, a variable actuator, and an integrated pathology system intended for the longer cores were developed and tested for this purpose. Testing was performed comparing 2 common cannula tip grinds, a Vet-point (sharp tip) and a Menghini-point (atraumatic tip), and were tested against 18-G Bard Monopty in porcine kidney. A variable actuator was developed to fire the needle 20-60 mm and tested in cadaver prostates. The aggregate firings for 3 different shot lengths comparing the Vet- with the Menghini-tip cannulas demonstrated 91% vs 85.2% fill (length of specimen/length of core bed, P = .007). A 15-G trocar needle with the Vet-tip cannula also had the best performance, with an aggregate standard deviation of 6.4% across 3 firing ranges and a minimum to maximum specimen length of 81%-105% of potential fill. Cadaver testing with the Vet-tip needles in the actuator for the transrectal (17-G) and transperineal (15-G) biopsies demonstrated mean fills of 93.3% and 76.5%, respectively. The new transrectal ultrasound needle obtained a 2-fold increase in specimen length over the standard Bard device (P <.001). Longer and consistent cores were obtained using the new biopsy needles. Combined with an adjustable actuator, the physician can obtain specimens that include peripheral and anterior zone tissue in 1 core. Determination of cancer location on the longer specimens could enhance focal therapy planning. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Schutter, K. J.; Gaume, J. G.; Duskin, F. E.
1981-01-01
Eight different seat cushion configurations were subjected to full-scale burn tests. Each cushion configuration was tested twice for a total of sixteen tests. Two different fire sources were used. They consisted of one liter of Jet A fuel for eight tests and a radiant energy source with propane flame for eight tests. Both fire sources were ignited by a propane flame. During each test, data were recorded for smoke density, cushion temperatures, radiant heat flux, animal response to combustion products, rate of weight loss of test specimens, cabin temperature, and for the type and content of gas within the cabin atmosphere. When compared to existing passenger aircraft seat cushions, the test specimens incorporating a fire barrier and those fabricated from advanced materials, using improved construction methods, exhibited significantly greater fire resistance.
Characterizing Delamination Migration in Carbon/Epoxy Tape Laminates
NASA Technical Reports Server (NTRS)
Ratcliffe, James G.; Czabaj, Michael W.; Obrien, Thomas K.
2012-01-01
A new test method is presented for the purpose of investigating migration of a delamination between neighboring ply interfaces in fiber-reinforced, polymer matrix tape laminates. The test is a single cantilever beam configuration consisting of a cross-ply laminate with a polytetrafluoroethylene (PTFE) insert implanted at the mid-plane and spanning part way along the length of the specimen. The insert is located between a 0-degree ply (specimen length direction) and a stack of four 90-degree plies (specimen width direction). The specimen is clamped at both ends onto a rigid baseplate and is loaded on its upper surface via a piano hinge. Tests were conducted with the load-application point located on the intact portion of the specimen in order to initiate delamination growth onset followed by migration of the delamination to a neighboring 90/0 ply interface by kinking through the 90- degree ply stack. Varying this position was found to affect the distance relative to the load-application point at which migration initiated. In each specimen, migration initiated by a gradual transition of the delamination at the 0/90 interface into the 90- degree ply stack. In contrast, transition of the kinked crack into the 90/0 interface was sudden. Fractography of the specimens indicated that delamination prior to migration was generally mixed mode-I/II. Inspection of the kink surface revealed mode-I fracture. In general, use of this test allows for the observation of the growth of a delamination followed by migration of the delamination to another ply interface, and should thus provide a means for validating analyses aimed at simulating migration.
NASA Technical Reports Server (NTRS)
Keller, C. W.; Cunnington, G. R.; Glassford, A. P.
1974-01-01
Experimental and analytical studies were conducted in order to extend previous knowledge of the thermal performance and gas evacuation characteristics of three selected multilayer insulation (MLI) composites. Flat plate calorimeter heat flux measurements were obtained for 20- and 80- shield specimens using three representative layer densities over boundary temperatures ranging from 39 K (70 R) to 389 K (700 R). Laboratory gas evacuation tests were performed on representative specimens of each MLI composite after initially purging them with helium, nitrogen, or argon gases. In these tests, the specimens were maintained at temperatures between 128 K (230 R) and 300 K (540 R). Based on the results of the laboratory-scale tests, a composite MLI system consisting of 112 unperforated, double-aluminized Mylar reflective shields and 113 water preconditioned silk net spacer pairs was fabricated and installed on a 1.22-m-(4-ft-) diameter calorimeter tank.
Crush testing, characterizing, and modeling the crashworthiness of composite laminates
NASA Astrophysics Data System (ADS)
Garner, David Michael, Jr.
Research in the field of crashworthiness of composite materials is presented. A new crush test method was produced to characterize the crush behavior of composite laminates. In addition, a model of the crush behavior and a method for rank ordering the energy absorption capability of various laminates were developed. The new crush test method was used for evaluating the crush behavior of flat carbon/epoxy composite specimens at quasi-static and dynamic rates. The University of Utah crush test fixture was designed to support the flat specimen against catastrophic buckling. A gap, where the specimen is unsupported, allowed unhindered crushing of the specimen. In addition, the specimen's failure modes could be clearly observed during crush testing. Extensive crush testing was conducted wherein the crush force and displacement data were collected to calculate the energy absorption, and high speed video was captured during dynamic testing. Crush tests were also performed over a range of fixture gap heights. The basic failure modes were buckling, crack growth, and fracture. Gap height variations resulted in poorly, properly, and overly constrained specimens. In addition, guidelines for designing a composite laminate for crashworthiness were developed. Modeling of the crush behavior consisted of the delamination and fracture of a single ply or group of like plies during crushing. Delamination crack extension was modeled using the mode I energy release rate, G lc, where an elastica approach was used to obtain the strain energy. Variations in Glc were briefly explored with double cantilever beam tests wherein crack extension occurred along a multidirectional ply interface. The model correctly predicted the failure modes for most of the test cases, and offered insight into how the input parameters affect the model. The ranking method related coefficients of the laminate and sublaminate stiffness matrices, the ply locations within the laminate, and the laminate thickness. The ranking method correctly ordered the laminates tested in this study with respect to their energy absorption.
21 CFR 866.5180 - Fecal calprotectin immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... immunological test system is an in vitro diagnostic device that consists of reagents used to quantitatively measure, by immunochemical techniques, fecal calprotectin in human stool specimens. The device is intended forin vitro diagnostic use as an aid in the diagnosis of inflammatory bowel diseases (IBD), specifically...
Acoustic fatigue and sound transmission characteristics of a ram composite panel design
NASA Technical Reports Server (NTRS)
Cockburn, J. A.; Chang, K. Y.; Kao, G. C.
1972-01-01
An experimental study to determine the acoustic fatigue characteristics of a flat multi-layered structural panel is described. The test panel represented a proposed design for the outer skin of a research application module to be housed within the space shuttle orbiter vehicle. The test specimen was mounted in one wall of the Wyle 100,000 cu ft reverberation room and exposed to a broadband acoustic environment having an overall level of 145 db. The test panel was exposed to nine separate applications of the acoustic environment, each application consisting of 250 seconds duration. Upon completion of the ninth test run, the specimen was exposed to a simulated micrometeoroid impact near the panel center. One additional test run of 250 seconds duration was then performed to complete the overall simulation of 50 flight missions. The experimental results show that no significant fatigue damage occurred until the test specimen was exposed to a simulated micrometeoroid impact. The intermediate foam layer forming the core of the test specimen suffered considerable damage due to this impact, causing a marked variation in the dynamic characteristics of the overall test panel. During the final application of the acoustic environment, the strain and acceleration response spectra showed considerable variation from those spectra obtained prior to impact of the panel. Fatigue damage from acoustic loading however, was limited to partial de-bonding around the edges of the composite panel.
Lockhart, Alexandre; Psioda, Matt; Ting, Jie; Campbell, Sara; Mugo, Nelly; Kwatampora, Jessie; Chitwa, Michael; Kimani, Joshua; Gakure, Anne; Smith, Jennifer S
2018-01-02
To examine the agreement between sexually transmitted infection (STI) screening using self-collected specimens and physician-collected specimens, and to investigate the acceptability of self-collection for screening in an 18-month study of female sex-workers (FSW) in a high-risk, low-resource setting. A total of 350 FSW in Nairobi, Kenya participated in a prospective study from 2009-2011. Women self-collected a cervico-vaginal specimen. Next, a physician conducted a pelvic examination to obtain a cervical specimen. Physician- and self-collected specimens were tested for Chlamydia trachomatis (CT), Neisseria gonorrhoeae (GC), Trichomonas vaginalis (TV) and Mycoplasma genitalium (MG) using Aptima nucleic acid amplification assays (Hologic). Specimens were collected at three-month intervals over 18-months follow-up. Kappa statistics measured agreement of positivity between self- and physician-collection. Baseline STI prevalence was 2.9% for GC, 5.2% for CT, 9.2% for TV, and 20.1% for MG in self-collected samples, and 2.3%, 3.7%, 7.2%, and 12.9% respectively in physician-collected samples. Kappa agreement was consistently strong (range 0.66-1.00) for all STIs over the 18-month study period, except MG which had moderate agreement (range: 0.50-0.75). Most participants found self-collection easy (94%) and comfortable (89%) at baseline, with responses becoming modestly more favorable over time. Self-collected specimens screening results showed strong agreement to clinical-collected specimens, except MG which was consistently detected more commonly in self- than physician-collected specimens. Acceptability of the self-collection procedure was high at baseline and increased modestly over time. In high-risk, low-resource settings, STI screening with self-collected specimens provides a reliable and acceptable alternative to screening with physician-collected specimens.
Characterization of Fatigue Damage for Bonded Composite Skin/Stringer Configurations
NASA Technical Reports Server (NTRS)
Paris, Isabelle; Cvitkovich, Michael; Krueger, Ronald
2008-01-01
The fatigue damage was characterized in specimens which consisted of a tapered composite flange bonded onto a composite skin. Quasi-static tension tests were performed first to determine the failure load. Subsequently, tension fatigue tests were performed at 40%, 50%, 60% and 70% of the failure load to evaluate the debonding mechanisms. For four specimens, the cycling loading was stopped at intervals. Photographs of the polished specimen edges were taken under a light microscope to document the damage. At two diagonally opposite corners of the flange, a delamination appeared to initiate at the flange tip from a matrix crack in the top 45deg skin ply and propagated at the top 45deg/-45deg skin ply interface. At the other two diagonally opposite corners, a delamination running in the bondline initiated from a matrix crack in the adhesive pocket. In addition, two specimens were cut longitudinally into several sections. Micrographs revealed a more complex pattern inside the specimen where the two delamination patterns observed at the edges are present simultaneously across most of the width of the specimen. The observations suggest that a more sophisticated nondestructive evaluation technique is required to capture the complex damage pattern of matrix cracking and multi-level delaminations.
NASA Technical Reports Server (NTRS)
Brueggeman, W C; Mayer, M JR
1948-01-01
Axial fatigue tests at zero mean stress have been made on 0.032- and 0.064-inch 24S-T and 0.032-inch 75S-T sheet-metal specimens 1/4, 1/2, 1, and 2 inches wide without a hole and with central holes giving a range of hole diameter D to specimen width W from 0.01 to 0.95. No systematic difference was noted between the results for the 0.032-inch and the 0.064-inch specimens although the latter seemed the more consistent. In general the fatigue strength based on the minimum section dropped sharply as the ration D/W was increased from zero to about 0.25. The plain specimens showed quite a pronounced decrease in fatigue strength with increasing width. The holed specimens showed only slight and rather inconclusive evidence of this size effect. The fatigue stress-concentration factor was higher for 75S-T than for 24S-T alloy. Evidence was found that a very small hole would not cause any reduction in fatigue strength.
An optical motion measuring system for laterally oscillated fatigue tests
NASA Technical Reports Server (NTRS)
Tripp, John S.; Tcheng, Ping; Murri, Gretchen B.; Sharpe, Scott
1993-01-01
This paper describes an optical system developed for materials testing laboratories at NASA Langley Research Center (LaRC) for high resolution monitoring of the transverse displacement and angular rotation of a test specimen installed in an axial-tension bending machine (ATB) during fatigue tests. It consists of a small laser, optics, a motorized mirror, three photodiodes, electronic detection and counting circuits, a data acquisition system, and a personal computer. A 3-inch by 5-inch rectangular plate attached to the upper grip of the test machine serves as a target base for the optical system. The personal computer automates the fatigue test procedure, controls data acquisition, performs data reduction, and provides user displays. The data acquisition system also monitors signals from up to 16 strain gages mounted on the test specimen. The motion measuring system is designed to continuously monitor and correlate the amplitude of the oscillatory motion with the strain gage signals in order to detect the onset of failure of the composite test specimen. A prototype system has been developed and tested which exceeds the design specifications of +/- 0.01 inch displacement accuracy, and +/- 0.25 deg angular accuracy at a sampling rate of 100 samples per second.
Mechanisms of deformation and fracture in high temperature low cycle fatigue of Rene 80 and IN 100
NASA Technical Reports Server (NTRS)
Romanoski, G. R., Jr.
1982-01-01
Specimens tested for the AGARD strain range partitioning program were investigated. Rene 80 and IN 100 were tested in air and in vacuum; at 871 C, 925 C, and 1000 C; and in the coated and uncoated condition. The specimens exhibited a multiplicity of high-temperature low-cycle fatigue damage. Observations of the various forms of damage were consistent with material and testing conditions and were generally in agreement with previous studies. In every case observations support a contention that failure occurs at a particular combination of crack length and maximum stress. A failure criterion which is applicable in the regime of testing studied is presented. The predictive capabilities of this criterion are straight forward.
Application of high-speed photography to the study of high-strain-rate materials testing
NASA Astrophysics Data System (ADS)
Ruiz, D.; Harding, John; Noble, J. P.; Hillsdon, Graham K.
1991-04-01
There is a growing interest in material behaviour at strain rates greater than 104sec1, for instance in the design of aero-engine turbine blades. It is necessary therefore, to develop material testing techniques that give well-defined information on mechanical behaviour in this very high strain-rate regime. A number of techniques are available, including the expanding ring test1, a miniaturised compression Hopkinson bar technique using direct impact and the double-notch shear test3 which has been described by Nicholas4 as "one of the most promising for future studies in dynamic plasticity". However, although it is believed to be a good test for determining the flow stress at shear strain rates of 104sec and above, the design of specimen used makes an accurate determination of strain extremely difficult while, in the later stages of the test the deformation mode involves rotation as well as shear. If this technique is to be used, therefore, it is necessary to examine in detail the progressive deformation and state of stress within the specimen during the impact process. An attempt can then be made to assess how far the data obtained is a reliable measure of the specimen material response and the test can be calibrated. An extensive three stage analysis has been undertaken. In the first stage, reported in a previous paper5, the initial elastic behaviour was studied. Dynamic photoelastic experiments were used to support linear elastic numerical results derived by the finite element method. Good qualitative agreement was obtained between the photoelastic experiment and the numerical model and the principal source of error in the elastic region of the double-notch shear test was identified as the assumption that all deformation of the specimen is concentrated in the two shear zones. For the epoxy (photoelastic) specimen a calibration factor of 5.3 was determined. This factor represents the ratio between the defined (nominal) gauge length and the effective gauge length. The second stage of the analysis of the double-notch shear (DNS) specimen is described in this paper. This consists of the use of ultra-high speed photography to provide information on the plastic deformation behaviour of the specimen. Two different high speed cine cameras were used for this work, a Hadland "Imacon" 792 electronic image converter camera and a Cordin 377 rotating mirror-drum optical camera. Implementation of the two cameras and photographic results are briefly compared and contrasted here. Stage three of this work consists of an advanced numerical analysis of the elasto-plastic, strain rate dependent behaviour of the DNS specimen. The principle intention of the authors was to use the physical data collected from high speed photographs for correlation with this work. Full details of the numerical work are presented elsewhere6 but some salient results will be given here for completeness.
Wear of ceramic and antagonist--a systematic evaluation of influencing factors in vitro.
Heintze, S D; Cavalleri, A; Forjanic, M; Zellweger, G; Rousson, V
2008-04-01
(1) To systematically review the existing literature on in vitro assessments of antagonist wear of ceramic materials; (2) To systematically evaluate possible influencing factors on material and antagonist wear of ceramic specimens. The database MEDLINE was searched with the terms "enamel," "wear" and "antagonist." The selected studies were analyzed with regard to wear parameters, type of antagonist and outcome. In the laboratory study, three ceramic materials were selected with different compositions and physical properties: IPS d.SIGN low-fusing metal ceramic, IPS Empress leucite ceramic, e.max Press lithium disilicate ceramic. These materials were subjected to the Ivoclar wear method (Willytec chewing simulator, 120,000cycles, 5kg weight) by systematically modifying the following variables which resulted in 36 tests with 8 specimens in each group: (1) configuration (flat, crown specimen), (2) surface treatment (polish, glaze), (3) type of antagonist (ceramic, two types of enamel stylus). Furthermore, the enamel styluses were cut to measure the enamel thickness and cusp width. Wear of both the material and the antagonist was quantified by scanning plaster replicas of the specimens with a laser scanner (etkon es1) and matching baseline and follow-up data with the Match 3D software (Willytec). The data were log-transformed to stabilize the variance and achieve near normality. To test the influence of specific test parameters, a four-way ANOVA with post hoc tests and Bonferroni correction was applied. The systematic review revealed 20 in vitro studies in which a material and the antagonist wear of the same material was examined. However, the results were inconsistent mainly due to the fact that the test parameters differed widely. Most studies used prepared enamel from extracted molars as the antagonist and flat polished ceramic specimens. The test chamber was filled with water and some sort of sliding movement was integrated in the wear generating process. However, there was a huge variation in relation to the applied force, the used force actuator, the number of cycles, and the frequency of cycles per time as well as the number of specimens. The results of the systematic laboratory tests revealed that the following factors strongly influence the wear: configuration (more material wear of flat versus crown specimens), surface treatment (more antagonist wear of glazed versus polished specimens), the antagonist system (more material wear and less antagonist wear for ceramic stylus versus enamel stylus), and enamel thickness (less wear for thicker enamel). Material wear was not very much different between the materials. However, e.max Press generally caused more antagonist wear than the other two materials, which were quite similar. However, the main influencing factors did not yield consistent results for all the subgroups and there was a huge variability of results within the subgroups especially in those groups that used enamel as antagonist. As far as consistency and correlation with clinical studies is concerned, the set-up that consists of unprepared enamel of molar cusps against glazed crowns seems to be the most appropriate method to evaluate a ceramic material with regard to antagonist wear. However, due to the high variability of results large sample sizes are necessary to differentiate between materials, which calls the whole in vitro approach into question.
NASA Technical Reports Server (NTRS)
Nettles, A. T.
2011-01-01
In this study, a direct comparison of the compression-after-impact (CAI) strength of impact-damaged, hat-stiffened and honeycomb sandwich structure for launch vehicle use was made. The specimens used consisted of small substructure designed to carry a line load of approx..3,000 lb/in. Damage was inflicted upon the specimens via drop weight impact. Infrared thermography was used to examine the extent of planar damage in the specimens. The specimens were prepared for compression testing to obtain residual compression strength versus damage severity curves. Results show that when weight of the structure is factored in, both types of structure had about the same CAI strength for a given damage level. The main difference was that the hat-stiffened specimens exhibited a multiphase failure whereas the honeycomb sandwich structure failed catastrophically.
NASA Technical Reports Server (NTRS)
Short, J. S.; Hyer, M. W.; Bowles, D. E.; Tompkins, S. S.
1982-01-01
The thermal expansion behavior of graphite epoxy laminates between 116 and 366 degrees Kelvin was investigated using as implementation of the Priest interferometer concept. The design, construction and use of the interferometer along with the experimental results it was used to generate are described. The experimental program consisted of 25 tests on 25.4 mm and 6.35 mm wide, 8 ply pi/4 quasi-isotropic T300-5208 graphite/epoxy specimens and 3 tests on a 25.4 mm wide unidirectional specimen. Experimental results are presented for all tests along with a discussion of the interferometer's limitations and some possible improvements in its design.
NASA Technical Reports Server (NTRS)
Phillips, Edward P.
1989-01-01
An experimental Round Robin on the measurement of the opening load in fatigue crack growth tests was conducted on Crack Closure Measurement and Analysis. The Round Robin evaluated the current level of consistency of opening load measurements among laboratories and to identify causes for observed inconsistency. Eleven laboratories participated in the testing of compact and middle-crack specimens. Opening-load measurements were made for crack growth at two stress-intensity factor levels, three crack lengths, and following an overload. All opening-load measurements were based on the analysis of specimen compliance data. When all of the results reported (from all participants, all measurement methods, and all data analysis methods) for a given test condition were pooled, the range of opening loads was very large--typically spanning the lower half of the fatigue loading cycle. Part of the large scatter in the reported opening-load results was ascribed to consistent differences in results produced by the various methods used to measure specimen compliance and to evaluate the opening load from the compliance data. Another significant portion of the scatter was ascribed to lab-to-lab differences in producing the compliance data when using nominally the same method of measurement.
Brown, Christopher U; Jacob, Gregor; Stoudt, Mark; Moylan, Shawn; Slotwinski, John; Donmez, Alkan
2016-08-01
Six different organizations participated in this interlaboratory study to quantify the variability in the tensile properties of Inconel 625 specimens manufactured using laser-powder-bed-fusion additive manufacturing machines. The tensile specimens were heat treated and tensile tests conducted until failure. The properties measured were yield strength, ultimate tensile strength, elastic modulus, and elongation. Statistical analysis revealed that between-participant variability for yield strength, ultimate tensile strength, and elastic modulus values were significantly higher (up to 4 times) than typical within-participant variations. Only between-participant and within-participant variability were both similar for elongation. A scanning electron microscope was used to examine one tensile specimen for fractography. The fracture surface does not have many secondary cracks or other features that would reduce the mechanical properties. In fact, the features largely consist of microvoid coalescence and are entirely consistent with ductile failure.
Brown, Christopher U.; Jacob, Gregor; Stoudt, Mark; Moylan, Shawn; Slotwinski, John; Donmez, Alkan
2017-01-01
Six different organizations participated in this interlaboratory study to quantify the variability in the tensile properties of Inconel 625 specimens manufactured using laser-powder-bed-fusion additive manufacturing machines. The tensile specimens were heat treated and tensile tests conducted until failure. The properties measured were yield strength, ultimate tensile strength, elastic modulus, and elongation. Statistical analysis revealed that between-participant variability for yield strength, ultimate tensile strength, and elastic modulus values were significantly higher (up to 4 times) than typical within-participant variations. Only between-participant and within-participant variability were both similar for elongation. A scanning electron microscope was used to examine one tensile specimen for fractography. The fracture surface does not have many secondary cracks or other features that would reduce the mechanical properties. In fact, the features largely consist of microvoid coalescence and are entirely consistent with ductile failure. PMID:28243032
NASA Astrophysics Data System (ADS)
Brown, Christopher U.; Jacob, Gregor; Stoudt, Mark; Moylan, Shawn; Slotwinski, John; Donmez, Alkan
2016-08-01
Six different organizations participated in this interlaboratory study to quantify the variability in the tensile properties of Inconel 625 specimens manufactured using laser powder bed fusion-additive manufacturing machines. The tensile specimens were heat treated and tensile tests were conducted until failure. The properties measured were yield strength, ultimate tensile strength, elastic modulus, and elongation. Statistical analysis revealed that between-participant variability for yield strength, ultimate tensile strength, and elastic modulus values were significantly higher (up to four times) than typical within-participant variations. Only between-participant and within-participant variability were both similar for elongation. A scanning electron microscope was used to examine one tensile specimen for fractography. The fracture surface does not have many secondary cracks or other features that would reduce the mechanical properties. In fact, the features largely consist of microvoid coalescence and are entirely consistent with ductile failure.
Evaluation of masonry coatings.
DOT National Transportation Integrated Search
1969-08-01
This report describes the evaluation of five coating systems to replace the conventional Class 2 rubbed finish now required on concrete structures. The evaluation consisted of preparing test specimens with each of the five coatings and conducting abs...
NASA Astrophysics Data System (ADS)
Shahrabadi, Hamid; Sayareh, Sina; Sarkardeh, Hamed
2017-12-01
In the present research, effect of silica fume as an additive and oil polluted sands as aggregates on compressive strength of concrete were investigated experimentally. The amount of oil in the designed mixtures was assumed to be constant and equal to 2% of the sand weight. Silica fume accounting for 10%, 15% and 20% of the weight is added to the designed mixture. After preparation and curing, concrete specimens were placed into the three different conditions: fresh, brackish and saltwater environments (submerged in fresh water, alternation of exposed in air & submerged in sea water and submerged in sea water). The result of compressive strength tests shows that the compressive strength of the specimens consisting of silica fume increases significantly in comparison with the control specimens in all three environments. The compressive strength of the concrete with 15% silica fume content was about 30% to 50% higher than that of control specimens in all tested environments under the condition of using polluted aggregates in the designed mixture.
2012-09-01
suspended in the runoff waters around the lakebeds, sealing lakebed surface cracks and filling fissures. Shallow flooding along with consistent winds are...of the recorded specimens consist of isolated fragments of tooth enamel or bone that are not securely dated. Irvingtonian fossil localities have...require frequent repair as well. Concrete floors are cracking throughout all four test cells. Entry doors sag and drag on buckled floors. One-half
Effect of Time and Temperature on Transformation Toughened Zirconias.
1987-06-01
room temperature. High temperature mechanical tests performed vere stress rupture and stepped temperature stress rupture. The results of the tests...tetragonal precipitates will spontaneously transform to the monoclinic phae due to the lattice mismatch stress if they become larger than about 0.2 on, with...specimens, including fast fracture and fracture toughness testing. High temper- ture testing consisting of stress rupture and stepped temperature stress
High-Temperature Adhesive Strain Gage Developed
NASA Technical Reports Server (NTRS)
Pereira, J. Michael; Roberts, Gary D.
1997-01-01
Researchers at the NASA Lewis Research Center have developed a unique strain gage and adhesive system for measuring the mechanical properties of polymers and polymer composites at elevated temperatures. This system overcomes some of the problems encountered in using commercial strain gages and adhesives. For example, typical commercial strain gage adhesives require a postcure at temperatures substantially higher than the maximum test temperature. The exposure of the specimen to this temperature may affect subsequent results, and in some cases may be higher than the glass-transition temperature of the polymer. In addition, although typical commercial strain gages can be used for short times at temperatures up to 370 C, their long-term use is limited to 230 C. This precludes their use for testing some high-temperature polyimides near their maximum temperature capability. Lewis' strain gage and adhesive system consists of a nonencapsulated, unbacked gage grid that is bonded directly to the polymer after the specimen has been cured but prior to the normal postcure cycle. The gage is applied with an adhesive specially formulated to cure under the specimen postcure conditions. Special handling, mounting, and electrical connection procedures were developed, and a fixture was designed to calibrate each strain gage after it was applied to a specimen. A variety of tests was conducted to determine the performance characteristics of the gages at elevated temperatures on PMR-15 neat resin and titanium specimens. For these tests, which included static tension, thermal exposure, and creep tests, the gage and adhesive system performed within normal strain gage specifications at 315 C. An example of the performance characteristics of the gage can be seen in the figure, which compares the strain gage measurement on a polyimide specimen at 315 C with an extensometer measurement.
Mechanical Properties of Aerogels
NASA Technical Reports Server (NTRS)
Parmenter, Kelly E.; Milstein, Frederick
1995-01-01
Aerogels are extremely low density solids that are characterized by a high porosity and pore sizes on the order of nanometers. Their low thermal conductivity and sometimes transparent appearance make them desirable for applications such as insulation in cryogenic vessels and between double paned glass in solar architecture. An understanding of the mechanical properties of aerogels is necessary before aerogels can be used in load bearing applications. In the present study, the mechanical behavior of various types of fiber-reinforced silica aerogels was investigated with hardness, compression, tension and shear tests. Particular attention was paid to the effects of processing parameters, testing conditions, storage environment, and age on the aerogels' mechanical response. The results indicate that the addition of fibers to the aerogel matrix generally resulted in softer, weaker materials with smaller elastic moduli. Furthermore, the testing environment significantly affected compression results. Tests in ethanol show an appreciable amount of scatter, and are not consistent with results for tests in air. In fact, the compression specimens appeared to crack and begin to dissolve upon exposure to the ethanol solution. This is consistent with the inherent hydrophobic nature of these aerogels. In addition, the aging process affected the aerogels' mechanical behavior by increasing their compressive strength and elastic moduli while decreasing their strain at fracture. However, desiccation of the specimens did not appreciably affect the mechanical properties, even though it reduced the aerogel density by removing trapped moisture. Finally, tension and shear test results indicate that the shear strength of the aerogels exceeds the tensile strength. This is consistent with the response of brittle materials. Future work should concentrate on mechanical testing at cryogenic temperatures, and should involve more extensive tensile tests. Moreover, before the mechanical response of reinforced aerogels can be fully understood, more tests of unreinforced aerogels are necessary. Unreinforced aerogels are of particular use because their birefringent nature allows for visual determination of stress fields during mechanical testing. The success of any future tests depends on the availability of a large supply of quality specimens with well-documented preparation and storage histories.
The Influence of Specimen Type on Tensile Fracture Toughness of Rock Materials
NASA Astrophysics Data System (ADS)
Aliha, Mohammad Reza Mohammad; Mahdavi, Eqlima; Ayatollahi, Majid Reza
2017-03-01
Up to now, several methods have been proposed to determine the mode I fracture toughness of rocks. In this research, different cylindrical and disc shape samples, namely: chevron bend (CB), short rod (SR), cracked chevron notched Brazilian disc (CCNBD), and semi-circular bend (SCB) specimens were considered for investigating mode I fracture behavior of a marble rock. It is shown experimentally that the fracture toughness values of the tested rock material obtained from different test specimens are not consistent. Indeed, depending on the geometry and loading type of the specimen, noticeable discrepancies can be observed for the fracture toughness of a same rock material. The difference between the experimental mode I fracture resistance results is related to the magnitude and sign of T-stress that is dependent on the geometry and loading configuration of the specimen. For the chevron-notched samples, the critical value of T-stress corresponding to the critical crack length was determined using the finite element method. The CCNBD and SR specimens had the most negative and positive T-stress values, respectively. The dependency of mode I fracture resistance to the T-stress was shown using the extended maximum tangential strain (EMTSN) criterion and the obtained experimental rock fracture toughness data were predicted successfully with this criterion.
ADAPTATION OF CRACK GROWTH DETECTION TECHNIQUES TO US MATERIAL TEST REACTORS
DOE Office of Scientific and Technical Information (OSTI.GOV)
A. Joseph Palmer; Sebastien P. Teysseyre; Kurt L. Davis
2015-04-01
A key component in evaluating the ability of Light Water Reactors to operate beyond 60 years is characterizing the degradation of materials exposed to radiation and various water chemistries. Of particular concern is the response of reactor materials to Irradiation Assisted Stress Corrosion Cracking (IASCC). Some test reactors outside the United States, such as the Halden Boiling Water Reactor (HBWR), have developed techniques to measure crack growth propagation during irradiation. The basic approach is to use a custom-designed compact loading mechanism to stress the specimen during irradiation, while the crack in the specimen is monitored in-situ using the Direct Currentmore » Potential Drop (DCPD) method. In 2012 the US Department of Energy commissioned the Idaho National Laboratory and the MIT Nuclear Reactor Laboratory (MIT NRL) to take the basic concepts developed at the HBWR and adapt them to a test rig capable of conducting in-pile IASCC tests in US Material Test Reactors. The first two and half years of the project consisted of designing and testing the loader mechanism, testing individual components of the in-pile rig and electronic support equipment, and autoclave testing of the rig design prior to insertion in the MIT Reactor. The load was applied to the specimen by means of a scissor like mechanism, actuated by a miniature metal bellows driven by pneumatic pressure and sized to fit within the small in-core irradiation volume. In addition to the loader design, technical challenges included developing robust connections to the specimen for the applied current and voltage measurements, appropriate ceramic insulating materials that can endure the LWR environment, dealing with the high electromagnetic noise environment of a reactor core at full power, and accommodating material property changes in the specimen, due primarily to fast neutron damage, which change the specimen resistance without additional crack growth. The project culminated with an in-pile demonstration at the MIT Reactor. The test rig and associated support equipment were used to apply loads to a representative Compact Tensile specimen during one MITR operating cycle, while measuring crack growth using the DCPD method. Although the test period was short (approximately 70 days), and the accumulated neutron dose relatively small, successful operation of the test rig was demonstrated. The specimen was cycled more than 8000 times (more than would be typical for a long term IASCC test), which was sufficient to propagate a crack of over 2 mm.« less
DEM code-based modeling of energy accumulation and release in structurally heterogeneous rock masses
NASA Astrophysics Data System (ADS)
Lavrikov, S. V.; Revuzhenko, A. F.
2015-10-01
Based on discrete element method, the authors model loading of a physical specimen to describe its capacity to accumulate and release elastic energy. The specimen is modeled as a packing of particles with viscoelastic coupling and friction. The external elastic boundary of the packing is represented by particles connected by elastic springs. The latter means introduction of an additional special potential of interaction between the boundary particles, that exercises effect even when there is no direct contact between the particles. On the whole, the model specimen represents an element of a medium capable of accumulation of deformation energy in the form of internal stresses. The data of the numerical modeling of the physical specimen compression and the laboratory testing results show good qualitative consistency.
Variation of Shrinkage Strain within the Depth of Concrete Beams.
Jeong, Jong-Hyun; Park, Yeong-Seong; Lee, Yong-Hak
2015-11-16
The variation of shrinkage strain within beam depth was examined through four series of time-dependent laboratory experiments on unreinforced concrete beam specimens. Two types of beam specimens, horizontally cast and vertically cast, were tested; shrinkage variation was observed in the horizontally cast specimens. This indicated that the shrinkage variation within the beam depth was due to water bleeding and tamping during the placement of the fresh concrete. Shrinkage strains were measured within the beam depth by two types of strain gages, surface-attached and embedded. The shrinkage strain distribution within the beam depth showed a consistent tendency for the two types of gages. The test beams were cut into four sections after completion of the test, and the cutting planes were divided into four equal sub-areas to measure the aggregate concentration for each sub-area of the cutting plane. The aggregate concentration increased towards the bottom of the beam. The shrinkage strain distribution was estimated by Hobbs' equation, which accounts for the change of aggregate volume concentration.
Variation of Shrinkage Strain within the Depth of Concrete Beams
Jeong, Jong-Hyun; Park, Yeong-Seong; Lee, Yong-Hak
2015-01-01
The variation of shrinkage strain within beam depth was examined through four series of time-dependent laboratory experiments on unreinforced concrete beam specimens. Two types of beam specimens, horizontally cast and vertically cast, were tested; shrinkage variation was observed in the horizontally cast specimens. This indicated that the shrinkage variation within the beam depth was due to water bleeding and tamping during the placement of the fresh concrete. Shrinkage strains were measured within the beam depth by two types of strain gages, surface-attached and embedded. The shrinkage strain distribution within the beam depth showed a consistent tendency for the two types of gages. The test beams were cut into four sections after completion of the test, and the cutting planes were divided into four equal sub-areas to measure the aggregate concentration for each sub-area of the cutting plane. The aggregate concentration increased towards the bottom of the beam. The shrinkage strain distribution was estimated by Hobbs’ equation, which accounts for the change of aggregate volume concentration. PMID:28793677
NASA Astrophysics Data System (ADS)
Guo, Wei; Li, Lin; Dong, Shiyun; Crowther, Dave; Thompson, Alan
2017-04-01
The microstructural characteristics and mechanical properties, including micro-hardness, tensile properties, three-point bending properties and Charpy impact toughness at different test temperatures of 8 mm thick S960 high strength steel plates were investigated following their joining by multi-pass ultra-narrow gap laser welding (NGLW) and gas metal arc welding (GMAW) techniques. It was found that the microstructure in the fusion zone (FZ) for the ultra-NGLW joint was predominantly martensite mixed with some tempered martensite, while the FZ for the GMAW joint was mainly consisted of ferrite with some martensite. The strength of the ultra-NGLW specimens was comparable to that of the base material (BM), with all welded specimens failed in the BM in the tensile tests. The tensile strength of the GMAW specimens was reduced approximately by 100 MPa when compared with the base material by a broad and soft heat affected zone (HAZ) with failure located in the soft HAZ. Both the ultra-NGLW and GMAW specimens performed well in three-point bending tests. The GMAW joints exhibited better impact toughness than the ultra-NGLW joints.
NASA Astrophysics Data System (ADS)
Koin, Sudibtia Titio; Triyono, Teguh; Surojo, Eko
2018-02-01
The 7075 series alloys are heat treatable wrought aluminum alloys based on the Al-Zn-Mg(-Cu) system. They are widely used in high-performance structural aerospace and transportation applications. Apart from compositional, casting and thermo-mechanical processing effects, the balance of properties is also significantly influenced by the way in which the materials are heat-treated. This paper describes the effect of flame hardening process to aluminum 7075 series on the increasing hardness, tensile strength, and evolution of microstructure. A test specimen had made by machining process and flame heating. Temperature of solution heat treatment is varied on 350 °C, 400 °C, 450 °C and 500 °C. After that process a test specimen would be quenched at nitrate-nitrite liquid during 45 minutes and artificial aging at 120°C until two days. The testing specimen consist of hardness and tensile strength according to ASTM. The result showed that specimen had precipitation on microstructure lead to an increase in aluminum properties. On the temperature 450°C solution heat treatment, the aluminum properties reached the highest value, namely, hardness of 129 HVN and tensile strength 570 MPa.
Anti-aging Friction of Carbonate Fault Mirror and its Microstructural Interpretation
NASA Astrophysics Data System (ADS)
Park, Y.; Ree, J. H.; Hirose, T.
2017-12-01
In our slide-hold-slide (SHS) friction tests on carbonate fault rocks, fault mirror (FM), light reflective mirror-like fault surface, shows almost zero or slightly negative aging rate of friction (`anti-aging' friction), whereas carbonate faults without FM exhibit a positive aging rate. We analyzed microstructures from three types of carbonate faults to explore the cause of the anti-aging friction of FM. The three types of fault rocks before SHS tests were made from Carrara marble; (i) FM, (ii) crushed gouge of former FM (CF), and (iii) gouge produced by pre-shearing of Carrara marble (PR). The fault zone of FM before SHS tests consists of sintered nanograin patches smeared into negative asperities of wall rocks (thickness up to 150 μm) and a sintered gouge layer between wall rocks (thickness up to 200 μm) that is composed of tightly-packed nanograins (50-500 nm in size) with triple junctions and angular-subangular fragments (a few-100 μm) of sintered nanograin aggregates. A straight and discrete Y-shear surface defines a boundary between the gouge layer and the nanograin patches or between the layer and wall rock. CF specimens before SHS tests are composed of patches of sintered nanograins as in FM specimens and a porous gouge layer with finer nanograins (a few-20 nm in size) and angular fragments of former FM. PR specimens before SHS tests are composed of damaged wall rocks and porous gouge with finer nanograins (a few-tens of μm). After SHS tests, sintered appearance of grains within the fault zones of CF and PR indicates the increase in interparticle bonding and also in contact area by grain aggregation. In contrast, the gouge layer of FM specimens after SHS tests consists mostly of angular fragments of sintered nanograin aggregates. The angular shape of the fragments indicates little increase in bonding and contact area between the fragments. Tightly sintered nanograins in FM specimens would have a lower chemical reactivity with their size coarser and sintering stronger than those of CF and PR. Furthermore, a high wear resistance of sintered nanograins of FM would prohibit generation of fine wear debris which may have led to the strenghtened interparticle bonding. Our results imply that anti-aging friction may be a common behavior other rocks' FM too, once they are composed of tightly sintered nanograins.
NASA Technical Reports Server (NTRS)
Parker, Bradford H.
1992-01-01
An acoustic emission (AE) system was set up in a linear location data acquisition mode to monitor the tensile loading of eight-ply quasi-isotropic graphite/epoxy specimens containing low velocity impact damage. The impact damage was induced using an instrumented drop weight tower. During impact, specimens were supported by either an aluminum plate or a membrane configuration. Cross-sectional examinations revealed that the aluminum plate configuration resulted in primarily matrix cracking and back surface fiber failure. The membrane support resulted in only matrix cracking and delamination damage. Penetrant enhanced radiography and immersion ultrasonics were used in order to assess the amount of impact damage in each tensile specimen. During tensile loading, AE reliably detected and located the damage sites which included fiber failure. All specimens with areas of fiber breakage ultimately failed at the impact site. AE did not reliably locate damage which consisted of only delaminations and matrix cracking. Specimens with this type of damage did not ultimately fail at the impact site. In summary, AE demonstrated the ability to increase the reliability of structural proof tests; however, the successful use of this technique requires extensive baseline testing.
Fatigue and fracture assessment of cracks in steel elements using acoustic emission
NASA Astrophysics Data System (ADS)
Nemati, Navid; Metrovich, Brian; Nanni, Antonio
2011-04-01
Single edge notches provide a very well defined load and fatigue crack size and shape environment for estimation of the stress intensity factor K, which is not found in welded elements. ASTM SE(T) specimens do not appear to provide ideal boundary conditions for proper recording of acoustic wave propagation and crack growth behavior observed in steel bridges, but do provide standard fatigue crack growth rate data. A modified versions of the SE(T) specimen has been examined to provide small scale specimens with improved acoustic emission(AE) characteristics while still maintaining accuracy of fatigue crack growth rate (da/dN) versus stress intensity factor (ΔK). The specimens intend to represent a steel beam flange subjected to pure tension, with a surface crack growing transverse to a uniform stress field. Fatigue test is conducted at low R ratio. Analytical and numerical studies of stress intensity factor are developed for single edge notch test specimens consistent with the experimental program. ABAQUS finite element software is utilized for stress analysis of crack tips. Analytical, experimental and numerical analysis were compared to assess the abilities of AE to capture a growing crack.
Imade, M; Fukuyama, S; Yokogawa, K
2008-07-01
A new type of apparatus for material tests using an internal loading system in high-pressure gas up to 100 MPa at room temperature without conventional material testing equipment was developed. The apparatus consists of a high-pressure control system and a pressure vessel, in which a piston is installed in the cylinder of the pressure vessel. The load caused by the pressure difference between spaces separated by the piston in the vessel cylinder is applied on the specimen connected to the piston in the vessel cylinder. The actual load on the specimen is directly measured by an external load cell and the displacement of the specimen is also measured by an external extensometer. As an example of the application of the apparatus, a tensile test on SUS316 stainless steel the Japanese Industrial Standard (JIS) G4303, which is comparable to the type 316 stainless steel ASTM A276, was conducted in 90 MPa hydrogen and argon. Hydrogen showed a marked effect on the tensile property of the material. The hydrogen gas embrittlement of the material was briefly discussed.
NASA Astrophysics Data System (ADS)
Imade, M.; Fukuyama, S.; Yokogawa, K.
2008-07-01
A new type of apparatus for material tests using an internal loading system in high-pressure gas up to 100MPa at room temperature without conventional material testing equipment was developed. The apparatus consists of a high-pressure control system and a pressure vessel, in which a piston is installed in the cylinder of the pressure vessel. The load caused by the pressure difference between spaces separated by the piston in the vessel cylinder is applied on the specimen connected to the piston in the vessel cylinder. The actual load on the specimen is directly measured by an external load cell and the displacement of the specimen is also measured by an external extensometer. As an example of the application of the apparatus, a tensile test on SUS316 stainless steel the Japanese Industrial Standard (JIS) G4303, which is comparable to the type 316 stainless steel ASTM A276, was conducted in 90MPa hydrogen and argon. Hydrogen showed a marked effect on the tensile property of the material. The hydrogen gas embrittlement of the material was briefly discussed.
Previous concrete as one of the technology to overcome the puddle
NASA Astrophysics Data System (ADS)
Agung Putra Handana, M.; Karolina, Rahmi; Syahputra, Eko; Zulfikar
2018-03-01
Some construction waste has been utilized as a material in certain concrete compositions for engineering building materials. One is a concrete that has been removed after testing at a laboratory called recycle concrete. Disposed concrete, crushed and filtered with filter number 50; 37.5; 19; 9.5; and 4.75 mm are subsequently converted into rough aggregate materials in the manufacture of pervious concrete to be tested for compressive strength and infiltration velocity to water. Pervious concrete test specimens in the form of cylinders with dimensions (15 x 30) cm and plate-shaped with dimension (100 x 100 x 10) cm with the quality plan Fc ' = 15 MPa at age 28 days. The research methodology consisted of testing of wear, test object preparation, periodic maintenance, visual inspection, compressive strength testing, and infiltration rate of specimens against water (based on ASTM C1701). Treatment of specimens by spraying periodically before the test time. From the results of the Los Angeles wear test, it appears that recycled aggregate has an average wear rate of 20.88% (based on SNI 03-2417-1991) on the Los Angeles test) and the visual test on the specimen is appropriate (based on SNI 03 -0691-1996 on paving block) as the basis for testing the specimens. The largest compressive strength was found in pervious concrete with 9.5 mm graded aggregates of 5.89 MPa, while the smallest compressive strength of 50 mm gradation was 2.15 MPa and had a compressive strength of 28% of pervious concrete compressive strength on generally (based on SNI 03-6805-2002). The fastest infiltration speed occurs in 50 mm pervious gradient concrete at 4.52 inc / hr and is late in 9.5 mm grading of 2.068 inc / hr or an inflation rate inflation rate of 54.25% for gradation of 9.5 mm to 50 mm gradation, So that in accordance with the purpose of pervious concrete use, concrete that can drain water to the bottom layer
NASA Astrophysics Data System (ADS)
Ogawa, Toshio; Dannoshita, Hiroyuki; Maruoka, Kuniaki; Ushioda, Kohsaku
2017-08-01
Microstructural evolution during cold rolling and subsequent annealing of low-carbon steel with different initial microstructures was investigated from the perspective of the competitive phenomenon between recrystallization of ferrite and reverse phase transformation from ferrite to austenite. Three kinds of hot-rolled sheet specimens were prepared. Specimen P consisted of ferrite and pearlite, specimen B consisted of bainite, and specimen M consisted of martensite. The progress of recovery and recrystallization of ferrite during annealing was more rapid in specimen M than that in specimens P and B. In particular, the recrystallized ferrite grains in specimen M were fine and equiaxed. The progress of ferrite-to-austenite phase transformation during intercritical annealing was more rapid in specimen M than in specimens P and B. In all specimens, the austenite nucleation sites were mainly at high-angle grain boundaries, such as those between recrystallized ferrite grains. The austenite distribution was the most uniform in specimen M. Thus, we concluded that fine equiaxed recrystallized ferrite grains were formed in specimen M, leading to a uniform distribution of austenite.
16 CFR 1630.61 - Hide carpets and rugs-alternative washing procedure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... natural “lay” of the hair structure for ten complete strokes. (8) Place test specimen in a circulating... procedure under FF 1-70 for testing the flammability of shearling and hide rugs that (1) consist of natural wool or hair attached to the hide with no synthetic fibers and (2) have been treated with a fire...
16 CFR 1630.61 - Hide carpets and rugs-alternative washing procedure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... natural “lay” of the hair structure for ten complete strokes. (8) Place test specimen in a circulating... procedure under FF 1-70 for testing the flammability of shearling and hide rugs that (1) consist of natural wool or hair attached to the hide with no synthetic fibers and (2) have been treated with a fire...
16 CFR 1630.61 - Hide carpets and rugs-alternative washing procedure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... natural “lay” of the hair structure for ten complete strokes. (8) Place test specimen in a circulating... procedure under FF 1-70 for testing the flammability of shearling and hide rugs that (1) consist of natural wool or hair attached to the hide with no synthetic fibers and (2) have been treated with a fire...
16 CFR 1631.61 - Hide carpets and rugs-alternative washing procedure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... natural “lay” of the hair structure for ten complete strokes. (8) Place test specimen in a circulating... procedure under FF 2-70 for testing the flammability of shearling and hide rugs that (1) consist of natural wool or hair attached to the hide with no synthetic fibers and (2) have been treated with a fire...
16 CFR 1631.61 - Hide carpets and rugs-alternative washing procedure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... natural “lay” of the hair structure for ten complete strokes. (8) Place test specimen in a circulating... procedure under FF 2-70 for testing the flammability of shearling and hide rugs that (1) consist of natural wool or hair attached to the hide with no synthetic fibers and (2) have been treated with a fire...
16 CFR 1631.61 - Hide carpets and rugs-alternative washing procedure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... natural “lay” of the hair structure for ten complete strokes. (8) Place test specimen in a circulating... procedure under FF 2-70 for testing the flammability of shearling and hide rugs that (1) consist of natural wool or hair attached to the hide with no synthetic fibers and (2) have been treated with a fire...
Fatigue Life Methodology for Tapered Composite Flexbeam Laminates
NASA Technical Reports Server (NTRS)
Murri, Gretchen B.; OBrien, T. Kevin; Rousseau, Carl Q.
1997-01-01
The viability of a method for determining the fatigue life of composite rotor hub flexbeam laminates using delamination fatigue characterization data and a geometric non-linear finite element (FE) analysis was studied. Combined tension and bending loading was applied to non-linear tapered flexbeam laminates with internal ply drops. These laminates, consisting of coupon specimens cut from a full-size S2/E7T1 glass-epoxy flexbeam were tested in a hydraulic load frame under combined axial-tension and transverse cyclic bending. The magnitude of the axial load remained constant and the direction of the load rotated with the specimen as the cyclic bending load was applied. The first delamination damage observed in the specimens occurred at the area around the tip of the outermost ply-drop group. Subsequently, unstable delamination occurred by complete delamination along the length of the specimen. Continued cycling resulted in multiple delaminations. A 2D finite element model of the flexbeam was developed and a geometrically non-linear analysis was performed. The global responses of the model and test specimens agreed very well in terms of the transverse displacement. The FE model was used to calculate strain energy release rates (G) for delaminations initiating at the tip of the outer ply-drop area and growing toward the thick or thin regions of the flexbeam, as was observed in the specimens. The delamination growth toward the thick region was primarily mode 2, whereas delamination growth toward the thin region was almost completely mode 1. Material characterization data from cyclic double-cantilevered beam tests was used with the peak calculated G values to generate a curve predicting fatigue failure by unstable delamination as a function of the number of loading cycles. The calculated fatigue lives compared well with the test data.
Fatigue Life Methodology for Tapered Composite Flexbeam Laminates
NASA Technical Reports Server (NTRS)
Murri, Gretchen B.; O''Brien, T. Kevin; Rousseau, Carl Q.
1997-01-01
The viability of a method for determining the fatigue life of composite rotor hub flexbeam laminates using delamination fatigue characterization data and a geometric non-linear finite element (FE) analysis was studied. Combined tension and bending loading was applied to nonlinear tapered flexbeam laminates with internal ply drops. These laminates, consisting of coupon specimens cut from a full-size S2/E7T1 glass-epoxy flexbeam were tested in a hydraulic load frame under combined axial-tension and transverse cyclic bending loads. The magnitude of the axial load remained constant and the direction of the load rotated with the specimen as the cyclic bending load was applied. The first delamination damage observed in the specimens occurred at the area around the tip of the outermost ply-drop group. Subsequently, unstable delamination occurred by complete delamination along the length of the specimen. Continued cycling resulted in multiple delaminations. A 2D finite element model of the flexbeam was developed and a geometrically non-linear analysis was performed. The global responses of the model and test specimens agreed very well in terms of the transverse flexbeam tip-displacement and flapping angle. The FE model was used to calculate strain energy release rates (G) for delaminations initiating at the tip of the outer ply-drop area and growing toward the thick or thin regions of the flexbeam, as was observed in the specimens. The delamination growth toward the thick region was primarily mode 2, whereas delamination growth toward the thin region was almost completely mode 1. Material characterization data from cyclic double-cantilevered beam tests was used with the peak calculated G values to generate a curve predicting fatigue failure by unstable delamination as a function of the number of loading cycles. The calculated fatigue lives compared well with the test data.
Standard Specimen Reference Set: Pancreatic — EDRN Public Portal
The primary objective of the EDRN Pancreatic Cancer Working Group Proposal is to create a reference set consisting of well-characterized serum/plasma specimens to use as a resource for the development of biomarkers for the early detection of pancreatic adenocarcinoma. The testing of biomarkers on the same sample set permits direct comparison among them; thereby, allowing the development of a biomarker panel that can be evaluated in a future validation study. Additionally, the establishment of an infrastructure with core data elements and standardized operating procedures for specimen collection, processing and storage, will provide the necessary preparatory platform for larger validation studies when the appropriate marker/panel for pancreatic adenocarcinoma has been identified.
NASA Technical Reports Server (NTRS)
Bunin, Bruce L.
1985-01-01
A program was conducted to develop the technology for critical structural joints in composite wing structure that meets all the design requirements of a 1990 commercial transport aircraft. The results of four large composite multirow bolted joint tests are presented. The tests were conducted to demonstrate the technology for critical joints in highly loaded composite structure and to verify the analytical methods that were developed throughout the program. The test consisted of a wing skin-stringer transition specimen representing a stringer runout and skin splice on the wing lower surface at the side of the fuselage attachment. All tests were static tension tests. The composite material was Toray T-300 fiber with Ciba-Geigy 914 resin in 10 mil tape form. The splice members were metallic, using combinations of aluminum and titanium. Discussions are given of the test article, instrumentation, test setup, test procedures, and test results for each of the four specimens. Some of the analytical predictions are also included.
Four-point Bend Testing of Irradiated Monolithic U-10Mo Fuel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rabin, B. H.; Lloyd, W. R.; Schulthess, J. L.
2015-03-01
This paper presents results of recently completed studies aimed at characterizing the mechanical properties of irradiated U-10Mo fuel in support of monolithic base fuel qualification. Mechanical properties were evaluated in four-point bending. Specimens were taken from fuel plates irradiated in the RERTR-12 and AFIP-6 Mk. II irradiation campaigns, and tests were conducted in the Hot Fuel Examination Facility (HFEF) at Idaho National Laboratory (INL). The monolithic fuel plates consist of a U-10Mo fuel meat covered with a Zr diffusion barrier layer fabricated by co-rolling, clad in 6061 Al using a hot isostatic press (HIP) bonding process. Specimens exhibited nominal (fresh)more » fuel meat thickness ranging from 0.25 mm to 0.64 mm, and fuel plate average burnup ranged from approximately 0.4 x 1021 fissions/cm 3 to 6.0 x 1021 fissions/cm 3. After sectioning the fuel plates, the 6061 Al cladding was removed by dissolution in concentrated NaOH. Pre- and post-dissolution dimensional inspections were conducted on test specimens to facilitate accurate analysis of bend test results. Four-point bend testing was conducted on the HFEF Remote Load Frame at a crosshead speed of 0.1 mm/min using custom-designed test fixtures and calibrated load cells. All specimens exhibited substantially linear elastic behavior and failed in a brittle manner. The influence of burnup on the observed slope of the stress-strain curve and the calculated fracture strength is discussed.« less
Softening due to disordered grain boundaries in nanocrystalline Co.
Yuasa, Motohiro; Hakamada, Masataka; Nakano, Hiromi; Mabuchi, Mamoru; Chino, Yasumasa
2013-08-28
Nanocrystalline Co consisting of fcc and hcp phases was processed by electrodeposition, and its mechanical properties were investigated by hardness tests. In addition, high-resolution transmission electron microscopy observations and molecular dynamics (MD) simulations were performed to investigate the grain boundary structure and dislocation nucleation from the grain boundaries. A large amount of disorders existed at the grain boundaries and stacking faults were formed from the grain boundaries in the as-deposited Co specimen. The as-deposited specimen showed a lower hardness than did the annealed specimen, although the grain size of the former was smaller than that of the latter. The activation volume of the as-deposited specimen (=1.5b(3)) was lower than that of the annealed specimen (=50b(3)), thus indicating that nucleation of dislocations from grain boundaries is more active in the as-deposited specimen than in the annealed specimens. The MD simulations showed that dislocation nucleation was closely related to a change in the defect structures at the boundary. Therefore, it is suggested that a significant amount of defects enhance changes in the defect structures at the boundary, resulting in softening of the as-deposited specimen.
Softening due to disordered grain boundaries in nanocrystalline Co
NASA Astrophysics Data System (ADS)
Yuasa, Motohiro; Hakamada, Masataka; Nakano, Hiromi; Mabuchi, Mamoru; Chino, Yasumasa
2013-08-01
Nanocrystalline Co consisting of fcc and hcp phases was processed by electrodeposition, and its mechanical properties were investigated by hardness tests. In addition, high-resolution transmission electron microscopy observations and molecular dynamics (MD) simulations were performed to investigate the grain boundary structure and dislocation nucleation from the grain boundaries. A large amount of disorders existed at the grain boundaries and stacking faults were formed from the grain boundaries in the as-deposited Co specimen. The as-deposited specimen showed a lower hardness than did the annealed specimen, although the grain size of the former was smaller than that of the latter. The activation volume of the as-deposited specimen (=1.5b3) was lower than that of the annealed specimen (=50b3), thus indicating that nucleation of dislocations from grain boundaries is more active in the as-deposited specimen than in the annealed specimens. The MD simulations showed that dislocation nucleation was closely related to a change in the defect structures at the boundary. Therefore, it is suggested that a significant amount of defects enhance changes in the defect structures at the boundary, resulting in softening of the as-deposited specimen.
Simulated Space Environmental Testing on Thin Films
NASA Technical Reports Server (NTRS)
Russell, Dennis A.; Fogdall, Larry B.; Bohnhoff-Hlavacek, Gail; Connell, John W. (Technical Monitor)
2000-01-01
An exploratory program has been conducted, to irradiate some mature commercial and some experimental polymer films with radiation simulating certain Earth orbits, and to obtain data about the response of each test film's reflective and tensile properties. Protocols to conduct optimized tests were considered and developed to a "prototype" level during this program. Fifteen polymer film specimens were arranged on a specially designed test fixture. The fixture featured controlled exposure areas, and protected the ends of the samples for later gripping in tensile tests. The fixture featured controlled exposure areas, and protected the ends of the samples for later gripping in tensile tests. The fixture containing the films was installed in a clean vacuum chamber where protons, electrons and solar ultraviolet (UV) radiation could simultaneously irradiate the specimens. Near realtime UV rates were used, whereas proton and electron rates were accelerated appreciably to simulate 5 years in orbit during a two month test. Periodically, the spectral reflectance of each film was measured in situ. After the end of the irradiation, final reflectance measurements were made in situ, and solar absorptance values were derived for each specimen. These samples were then measured in air for thermal emittance and for tensile strength. Most specimens withstood the irradiation intact, but with reduced reflectance (increased solar absorptance). Thermal emittance changed slightly in several materials, as did their tensile strength and elongation at break. Conclusions are drawn about the performance of the films. Simulated testing to an expected 5 year dose of electrons and protons consistent with those expected at L2 and 0.98 AU orbits and 100 equivalent solar hours exposure.
Small scale mechanical characterization of thin foil materials via pin load microtesting
Wheeler, Robert; Pandey, Amit; Shyam, Amit; ...
2015-05-06
In situ scanning electron microscope (SEM) experiments, where small-scale mechanical tests are conducted on micro- and nanosized specimens, allow direct visualization of elastic and plastic responses over the entirety of the volume being deformed. This enables precise spatial and temporal correlation of slip events contributing to the plastic flow evidenced in a stress–strain curve. A new pin-loading methodology has been employed, in situ within the SEM, to conduct microtensile tests on thin polycrystalline metal foils. This approach can be tailored to a specific foil whose particular grain size may range from microns to tens of microns. Manufacture of the specializedmore » pin grip was accomplished via silicon photolithography-based processing followed by subsequent focused ion beam finishing. Microtensile specimen preparation was achieved by combining a stencil mask methodology employing broad ion beam sputtering along with focused ion beam milling in the study of several metallic foil materials. Finite-element analyses were performed to characterize the stress and strain distributions in the pin grip and micro-specimen under load. Furthermore, under appropriately conceived test conditions, uniaxial stress–strain responses measured within these foils by pin-load microtensile testing exhibit properties consistent with larger scale tests.« less
Photodiode Camera Measurement of Surface Strains on Tendons during Multiple Cyclic Tests
NASA Astrophysics Data System (ADS)
Chun, Keyoung Jin; Hubbard, Robert Philip
The objectives of this study are to introduce the use of a photodiode camera for measuring surface strain on soft tissue and to present some representative responses of the tendon. Tendon specimens were obtained from the hindlimbs of canines and frozen to -70°C. After thawing, specimens were mounted in the immersion bath at a room temperature (22°C), preloaded to 0.13N and then subjected to 3% of the initial length at a strain rate of 2%/sec. In tendons which were tested in two blocks of seven repeated extensions to 3% strain with a 120 seconds wait period between, the surface strains were measured with a photodiode camera and near the gripped ends generally were greater than the surface strains in the middle segment of the tendon specimens. The recovery for peak load after the rest period was consistent but the changes in patterns of surface strains after the rest period were not consistent. The advantages of a photodiode measurement of surface strains include the followings: 1) it is a noncontacting method which eliminates errors and distortions caused by clip gauges or mechanical/electronic transducers; 2) it is more accurate than previous noncontact methods, e.g. the VDA and the high speed photographic method; 3) it is a fully automatic, thus reducing labor for replaying video tapes or films and potential errors from human judgement which can occur during digitizing data from photographs. Because the photodiode camera, employs a solid state photodiode array to sense black and white images, scan targets (black image) on the surface of the tendon specimen and back lighting system (white image), and stored automatically image data for surface strains of the tendon specimen on the computer during cyclic extensions.
Heat transfer in a compact tubular heat exchanger with helium gas at 3.5 MPa
NASA Technical Reports Server (NTRS)
Olson, Douglas A.; Glover, Michael P.
1990-01-01
A compact heat exchanger was constructed consisting of circular tubes in parallel brazed to a grooved base plate. This tube specimen heat exchanger was tested in an apparatus which radiatively heated the specimen on one side at a heat flux of up to 54 W/sq cm, and cooled the specimen with helium gas at 3.5 MPa and Reynolds numbers of 3000 to 35,000. The measured friction factor of the tube specimen was lower than that of a circular tube with fully developed turbulent flow, although the uncertainty was high due to entrance and exit losses. The measured Nusselt number, when modified to account for differences in fluid properties between the wall and the cooling fluid, agreed with past correlations for fully developed turbulent flow in circular tubes.
NASA Astrophysics Data System (ADS)
Byrd, Larry; Rickerd, Greg; Wyen, Travis; Cooley, Glenn; Quast, Jeff
2008-02-01
Sonic fatigue of aircraft is characterized by fully reversed bending of components subjected to acoustic excitation. This problem is compounded in high temperature environments because solutions for acoustics which tend to result in stiff structures make thermal problems worse. Conversely solutions to the thermal problem which allow expansion often fail in the presence of high acoustic levels. Errors in fatigue life prediction in the combined environment often range from a factor of 4 to 10. This results in either heavy, overly stiff structure or premature failure. This work will test the hypothesis that the fatigue life of a layered functionally graded material (FGM) will be dominated by the failure of the stiffest outer layer. This is based on the observation that for isotropic materials the life is approximately 90% crack initiation and only 10% crack growth before failure. Four sets of cantilever specimens will be tested using an electro-mechanical shaker for base excitation. The excitation will be narrow band random around the fundamental frequency. Two sets of specimens are of uniform composition consisting of 85%TiB/Ti and two are graded specimens consisting of layers that vary from commercially pure titanium to 85%TiB/Ti. Strain vs number of cycles to failure curves will be generated with both constant amplitude sine and narrow band random around the fundamental frequency excitation. The results will be examined to compare life of the uniform material to the functionally graded material. Also to be studied will be the use of Miner's rule to predict the fatigue life of the randomly excited specimens.
Raymond, Frédéric; Carbonneau, Julie; Boucher, Nancy; Robitaille, Lynda; Boisvert, Sébastien; Wu, Whei-Kuo; De Serres, Gaston; Boivin, Guy; Corbeil, Jacques
2009-01-01
Respiratory virus infections are a major health concern and represent the primary cause of testing consultation and hospitalization for young children. We developed and compared two assays that allow the detection of up to 23 different respiratory viruses that frequently infect children. The first method consisted of single TaqMan quantitative real-time PCR assays in a 96-well-plate format. The second consisted of a multiplex PCR followed by primer extension and microarray hybridization in an integrated molecular diagnostic device, the Infiniti analyzer. Both of our assays can detect adenoviruses of groups A, B, C, and E; coronaviruses HKU1, 229E, NL63, and OC43; enteroviruses A, B, C, and D; rhinoviruses of genotypes A and B; influenza viruses A and B; human metapneumoviruses (HMPV) A and B, human respiratory syncytial viruses (HRSV) A and B; and parainfluenza viruses of types 1, 2, and 3. These tests were used to identify viruses in 221 nasopharyngeal aspirates obtained from children hospitalized for respiratory tract infections. Respiratory viruses were detected with at least one of the two methods in 81.4% of the 221 specimens: 10.0% were positive for HRSV A, 38.0% for HRSV B, 13.1% for influenzavirus A, 8.6% for any coronaviruses, 13.1% for rhinoviruses or enteroviruses, 7.2% for adenoviruses, 4.1% for HMPV, and 1.5% for parainfluenzaviruses. Multiple viral infections were found in 13.1% of the specimens. The two methods yielded concordant results for 94.1% of specimens. These tests allowed a thorough etiological assessment of respiratory viruses infecting children in hospital settings and would assist public health interventions. PMID:19158263
Raymond, Frédéric; Carbonneau, Julie; Boucher, Nancy; Robitaille, Lynda; Boisvert, Sébastien; Wu, Whei-Kuo; De Serres, Gaston; Boivin, Guy; Corbeil, Jacques
2009-03-01
Respiratory virus infections are a major health concern and represent the primary cause of testing consultation and hospitalization for young children. We developed and compared two assays that allow the detection of up to 23 different respiratory viruses that frequently infect children. The first method consisted of single TaqMan quantitative real-time PCR assays in a 96-well-plate format. The second consisted of a multiplex PCR followed by primer extension and microarray hybridization in an integrated molecular diagnostic device, the Infiniti analyzer. Both of our assays can detect adenoviruses of groups A, B, C, and E; coronaviruses HKU1, 229E, NL63, and OC43; enteroviruses A, B, C, and D; rhinoviruses of genotypes A and B; influenza viruses A and B; human metapneumoviruses (HMPV) A and B, human respiratory syncytial viruses (HRSV) A and B; and parainfluenza viruses of types 1, 2, and 3. These tests were used to identify viruses in 221 nasopharyngeal aspirates obtained from children hospitalized for respiratory tract infections. Respiratory viruses were detected with at least one of the two methods in 81.4% of the 221 specimens: 10.0% were positive for HRSV A, 38.0% for HRSV B, 13.1% for influenzavirus A, 8.6% for any coronaviruses, 13.1% for rhinoviruses or enteroviruses, 7.2% for adenoviruses, 4.1% for HMPV, and 1.5% for parainfluenzaviruses. Multiple viral infections were found in 13.1% of the specimens. The two methods yielded concordant results for 94.1% of specimens. These tests allowed a thorough etiological assessment of respiratory viruses infecting children in hospital settings and would assist public health interventions.
Effect of tulle on the mechanical properties of a maxillofacial silicone elastomer.
Gunay, Yumushan; Kurtoglu, Cem; Atay, Arzu; Karayazgan, Banu; Gurbuz, Cihan Cem
2008-11-01
The purpose of this research was to investigate if physical properties could be improved by incorporating a tulle reinforcement material into a maxillofacial silicone elastomer. A-2186 silicone elastomer was used in this study. The study group consisted of 20 elastomer specimens incorporated with tulle and fabricated in dumbbell-shaped silicone patterns using ASTM D412 and D624 standards. The control group consisted of 20 elastomer specimens fabricated without tulle. Tensile strength, ultimate elongation, and tear strength of all specimens were measured and analyzed. Statistical analyses were performed using Mann-Whitney U test with a statistical significance at 95% confidence level. It was found that the tensile and tear strengths of tulle-incorporated maxillofacial silicone elastomer were higher than those without tulle incorporation (p < 0.05). Therefore, findings of this study suggested that tulle successfully reinforced a maxillofacial silicone elastomer by providing it with better mechanical properties and augmented strength--especially for the delicate edges of maxillofacial prostheses.
Kim, Young-gon; Kim, Min Young; Park, Kwisung; Cho, Chi Hyun; Yoon, Soo Young; Nam, Myung Hyun; Lee, Chang Kyu; Cho, Yun-Jung; Lim, Chae Seung
2016-01-01
ABSTRACT Nasopharyngeal swabs (NPSs) are being widely used as specimens for multiplex real-time reverse transcription (RT)-PCR for respiratory virus detection. However, it remains unclear whether NPS specimens are optimal for all viruses targeted by multiplex RT-PCR. In addition, the procedure to obtain NPS specimens causes coughing in most patients, which possibly increases the risk of nosocomial spread of viruses. In this study, paired NPS and saliva specimens were collected from 236 adult male patients with suspected acute respiratory illnesses. Specimens were tested for 16 respiratory viruses by multiplex real-time RT-PCR. Among the specimens collected from the 236 patients, at least 1 respiratory virus was detected in 183 NPS specimens (77.5%) and 180 saliva specimens (76.3%). The rates of detection of respiratory viruses were comparable for NPS and saliva specimens (P = 0.766). Nine virus species and 349 viruses were isolated, 256 from NPS specimens and 273 from saliva specimens (P = 0.1574). Adenovirus was detected more frequently in saliva samples (P < 0.0001), whereas influenza virus type A and human rhinovirus were detected more frequently in NPS specimens (P = 0.0001 and P = 0.0289, respectively). The possibility of false-positive adenovirus detection from saliva samples was excluded by direct sequencing. In conclusion, neither of the sampling methods was consistently more sensitive than the other. We suggest that these cost-effective methods for detecting respiratory viruses in mixed NPS-saliva specimens might be valuable for future studies. PMID:27807150
A Validation Study of the Impression Replica Technique.
Segerström, Sofia; Wiking-Lima de Faria, Johanna; Braian, Michael; Ameri, Arman; Ahlgren, Camilla
2018-04-17
To validate the well-known and often-used impression replica technique for measuring fit between a preparation and a crown in vitro. The validation consisted of three steps. First, a measuring instrument was validated to elucidate its accuracy. Second, a specimen consisting of male and female counterparts was created and validated by the measuring instrument. Calculations were made for the exact values of three gaps between the male and female. Finally, impression replicas were produced of the specimen gaps and sectioned into four pieces. The replicas were then measured with the use of a light microscope. The values received from measuring the specimen were then compared with the values received from the impression replicas, and the technique was thereby validated. The impression replica technique overvalued all measured gaps. Depending on location of the three measuring sites, the difference between the specimen and the impression replicas varied from 47 to 130 μm. The impression replica technique overestimates gaps within the range of 2% to 11%. The validation of the replica technique enables the method to be used as a reference when testing other methods for evaluating fit in dentistry. © 2018 by the American College of Prosthodontists.
Evaluation of Deicer Impacts on Pervious Concrete Specimens (Phase II)
DOT National Transportation Integrated Search
2018-05-01
This research examined the chemical degradation of pervious concrete due to calcium chloride or magnesium chloride deicers. The project consisted of Phase I, Phase IIa, and Phase IIb. Phase I was previous work where a testing protocol was developed t...
16 CFR § 1630.61 - Hide carpets and rugs-alternative washing procedure.
Code of Federal Regulations, 2013 CFR
2013-01-01
... natural “lay” of the hair structure for ten complete strokes. (8) Place test specimen in a circulating... procedure under FF 1-70 for testing the flammability of shearling and hide rugs that (1) consist of natural wool or hair attached to the hide with no synthetic fibers and (2) have been treated with a fire...
16 CFR § 1631.61 - Hide carpets and rugs-alternative washing procedure.
Code of Federal Regulations, 2013 CFR
2013-01-01
... natural “lay” of the hair structure for ten complete strokes. (8) Place test specimen in a circulating... procedure under FF 2-70 for testing the flammability of shearling and hide rugs that (1) consist of natural wool or hair attached to the hide with no synthetic fibers and (2) have been treated with a fire...
Samano, Kimberly L; Anne, Lakshmi; Johnson, Ted; Tang, Kenneth; Sample, R H Barry
2015-10-01
Oral fluid (OF) is increasingly used for clinical, forensic and workplace drug testing as an alternative to urine. Uncertainties surrounding OF collection device performance, drug stability and testing reproducibility may be partially responsible for delays in the implementation of OF testing in regulated drug testing programs. Stability of Δ(9)-tetrahydrocannabinol (THC) fortified and authentic specimens was examined after routine collection, transport and laboratory testing. Acceptable recovery and stability were observed when THC-fortified OF (1.5 and 4.5 ng/mL) was applied to Oral-Eze devices. Neat OF samples collected with Oral-Eze, processed per the package insert, and fortified with THC (3 and 6 ng/mL) were stable (±20%) at room temperature (21-25°C), refrigerated (2-8°C) and frozen (-25 to -15°C) conditions up to 1 month, while samples collected with Intercept devices showed decreases at refrigerated and room temperatures. After long-term refrigerated or frozen storage, maximum reductions in THC concentrations were 42% for Oral-Eze and 69% for Intercept. After ≥1 year frozen storage, 80.7% of laboratory specimens positive for THC (3 ng/mL cut-off) by GC-MS were reconfirmed positive (within 25%), with an average THC decrease of 4.2%. Specimens (n = 47) processed with Oral-Eze (diluted) and tested via enzyme immunoassay were concordant with LC-MS-MS results and showed 100% sensitivity and 95% specificity. Paired specimens collected with Oral-Eze and Intercept exhibited 98% overall agreement between the immunoassay test systems. Collectively, these data demonstrate consistent and reproducible recovery and stability of THC in OF after collection, transport and laboratory testing using the Oral-Eze OF Collection System. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Method for hygromechanical characterization of graphite/epoxy composite
NASA Technical Reports Server (NTRS)
Yaniv, Gershon; Peimanidis, Gus; Daniel, Isaac M.
1987-01-01
An experimental method is described for measuring hygroscopic swelling strains and mechanical strains of moisture-conditioned composite specimens. The method consists of embedding encapsulated strain gages in the midplane of the composite laminate; thus it does not interfere with normal moisture diffusion. It is particularly suited for measuring moisture swelling coefficients and for mechanical testing of moisture-conditioned specimens at high strain rates. Results obtained by the embedded gage method were shown to be more reliable and reproducible than those obtained by surface gages, dial gages, or extensometers.
Zhang, Wei; Chen, Chuanhui; Cui, Jian; Bai, Wei; Zhou, Jing
2015-01-01
The present study explores the application of LAMP for rapid diagnosis of pathogenic bacteria in clinical sputum specimens of AECOPD as compared with conventional sputum culturing method. 120 sputum specimens of AECOPD patients, 46 sputum specimens of healthy controls, as well as 166 serum specimens as negative controls, were evaluated by LAMP assay using primers of eight typical respiratory pathogens. No cross-reactivity was observed in these negative control species using LAMP assay. The lower detection limit of LAMP assay was approximately 10(3) copies. 25 cases (20.8%) were detected at least one positive bacteria species by conventional sputum culturing method, while 73 cases (60.8%) were tested positive in LAMP assay. Moreover, compared with sputum culture, bacterial titers results of LAMP assay were more consistent with FEV1/FVC value of AECOPD patients. These results indicated that the sensitivity of LAMP assay was significantly higher than that of sputum culturing method.
Reliability of fracture appearance measurement in the Charpy test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dixon, B.F.
1994-12-31
Despite conventional wisdom, the Charpy fracture appearance transition curve does not always coincide with the energy transition curve. Furthermore, unlike Charpy energy, fracture appearance tells how a specimen failed. It can therefore be used to meaningfully relate the results of Charpy testing to results of other toughness tests which may employ different geometries and loading rates. In order to address the question of consistency, a set of 20 specimens was prepared and used in a `round robin` survey. Results showed that agreement was greatest when operators are experienced, samples are close to fracture appearance transition, and simple, two-dimensional diagrams aremore » sued for assessment. It was also found that certain inconsistencies exist between various assessment techniques for Charpy fracture appearance. As a part of this work, fracture appearance curves were compared to energy impact curves for the Charpy test and a similar test, the Schnadt K{sub o} test, which uses a sharp pressed notch. It was found that energy and fracture appearance transition may differ by as much as 50{degrees}C in the Charpy test while the two curves coincided in the Schnadt test. In series of toughness tests on 132 steels, the average difference between Charpy energy transition and Schnade K{sub o} energy transition was about 27{degrees}C. This is believed to represent the difference in toughness between blunt and sharp notches in Charpy size specimens.« less
NASA Astrophysics Data System (ADS)
Woo, Ik; Song, Won-Kyong; Kim, Bok-Chul; Kang, Jinseok
2010-05-01
Dokdo consists of small volcanic islands located in the southern part of the East Sea. Accelerated weathering tests was performed to examine the physico-mechanical characteristics of volcanic rocks in Dokdo. Rock core specimens of trachyandesite, andesitic dyke and ash tuff were prepared, and double soxhlet extractors(DSE) and peristatic pumps were used for accelerating the weathering processes. The DSE was designed to perform cyclic leaching tests for rock core specimen using distilled water at seventy degrees centigrade. The core specimens which are classified according to pre-test weathering grades placed in the lower part of the DSE, and periodically exposed to hot distilled water at every ninety minutes. On the other hand the peristatic pumps were utilized to induce leaching by distilled or brine water at normal temperature. The physico-mechanical property changes including rock surface appearance, microscopic structure and rock strength were analyzed with the results obtained from both experiments performed for 120 days. The conducted research in this study have shown that the methodologies of artificial weathering experiments have strong capability to understand the weathering characteristics of the rocks effectively.
Experimental investigation of reinforced bonded joints for composite laminates.
Bisagni, Chiara; Furfari, Domenico; Pacchione, Marco
2018-02-01
An experimental study has been carried out to investigate the behaviour of co-bonded carbon fibre reinforced plastics joints with a novel design incorporating a through the thickness local reinforcement. Different specimens were manufactured to investigate static and fatigue behaviour, as well as delamination size after impact and damage tolerance characteristics. The mechanical performances of the specimens with local reinforcement, consisting of the insertion of spiked thin metal sheets between co-bonded laminates, were compared with those ones obtained from specimens with purely co-bonded joints. This novel design demonstrated by tests that damage progression under cycling load results significantly delayed by the reinforcements. A significant number of experimental results were obtained that can be used to define preliminary design guidelines.
Experimental investigation of reinforced bonded joints for composite laminates
Bisagni, Chiara; Furfari, Domenico; Pacchione, Marco
2017-01-01
An experimental study has been carried out to investigate the behaviour of co-bonded carbon fibre reinforced plastics joints with a novel design incorporating a through the thickness local reinforcement. Different specimens were manufactured to investigate static and fatigue behaviour, as well as delamination size after impact and damage tolerance characteristics. The mechanical performances of the specimens with local reinforcement, consisting of the insertion of spiked thin metal sheets between co-bonded laminates, were compared with those ones obtained from specimens with purely co-bonded joints. This novel design demonstrated by tests that damage progression under cycling load results significantly delayed by the reinforcements. A significant number of experimental results were obtained that can be used to define preliminary design guidelines. PMID:29568127
NASA Technical Reports Server (NTRS)
OBrien, T. Kevin; Paris, Isabelle L.
2004-01-01
Small sub-component specimens consisting of solid laminates at the ends that transition to X-cor(R) truss sandwich in the center, were tested in a combination of three point bending, uni-axial tension, and combined tension and bending. The failure process in the transition region was documented for each loading using digital video and high-resolution cameras. For the 3-point bending tests, most of the deformation occurred in the solid laminate regions on either end of the specimen. Some pin debonding from the skin of the X-cor(R) truss sandwich was observed in the transition region and was accompanied by audible "pings" throughout the loading. Tension loaded specimens failed in the sandwich skin in the middle of the gage length, accompanied by separation of the sandwich core from the back skin and by delamination between the top skin and bottom skin at the transition region. The pinging associated with pin debonding occurred as the load was increased. However, the frequency of the pinging exceeded any visual observations of pin debonding in the video of the transition region. For specimens tested in combined tension and bending, the greatest amount of pinging occurred during initial application of the axial load. High-resolution images in the transition region indicated that the pinging corresponded to pins debonding and buckling due to the through-thickness Poisson contraction of the specimen. This buckling continued to a much smaller extent as the transverse load was applied.
Calcified lesion modeling for excimer laser ablation
NASA Astrophysics Data System (ADS)
Scott, Holly A.; Archuleta, Andrew; Splinter, Robert
2009-06-01
Objective: Develop a representative calcium target model to evaluate penetration of calcified plaque lesions during atherectomy procedures using 308 nm Excimer laser ablation. Materials and Methods: An in-vitro model representing human calcified plaque was analyzed using Plaster-of-Paris and cement based composite materials as well as a fibrinogen model. The materials were tested for mechanical consistency. The most likely candidate(s) resulting from initial mechanical and chemical screening was submitted for ablation testing. The penetration rate of specific multi-fiber catheter designs and a single fiber probe was obtained and compared to that in human cadaver calcified plaque. The effects of lasing parameters and catheter tip design on penetration speed in a representative calcified model were verified against the results in human cadaver specimens. Results: In Plaster of Paris, the best penetration was obtained using the single fiber tip configuration operating at 100 Fluence, 120 Hz. Calcified human lesions are twice as hard, twice as elastic as and much more complex than Plaster of Paris. Penetration of human calcified specimens was highly inconsistent and varied significantly from specimen to specimen and within individual specimens. Conclusions: Although Plaster of Paris demonstrated predictable increases in penetration with higher energy density and repetition rate, it can not be considered a totally representative laser ablation model for calcified lesions. This is in part due to the more heterogeneous nature and higher density composition of cadaver intravascular human calcified occlusions. Further testing will require a more representative model of human calcified lesions.
A regional centralized microbiology service in Calgary for the rapid diagnosis of malaria.
Church, Deirdre L; Lichtenfeld, Angelika; Elsayed, Sameer; Kuhn, Susan; Gregson, Daniel B
2003-06-01
A regional centralized laboratory service for the rapid diagnosis of malaria was implemented 3 years ago in May 1999 within the Division of Microbiology, Calgary Laboratory Services. To describe the design and performance of this unique microbiology laboratory service. Blood specimens must arrive at the central laboratory within 2 hours of collection. Thin blood smears are read and reported from suspected acute cases within 1 hour of receipt, 24 hours per day, 7 days a week, by trained and experienced microbiology technologists. All positive malaria smears are reviewed by a medical microbiologist and confirmed by polymerase chain reaction at a reference laboratory. Calgary Laboratory Services provides integrated laboratory services to the Calgary Health Region, an urban area of more than 1 million people. Performance of the service has been continuously monitored by measuring preanalytic and analytic test turnaround times, test accuracy, clinical relevance, and the results of proficiency testing. More than 90% of blood specimens for malaria from community locations have consistently arrived within 2 hours of collection, and hospitals have reached this target within the past year. Although polymerase chain reaction was more sensitive at detecting the presence of malaria, the expert microscopists were as accurate at determining the type of Plasmodium infection. More than 95% of all positive smear results are consistently reported within 2 hours of receipt of a blood specimen. Implementation of a regional centralized microbiology service has improved our ability to make a rapid and accurate diagnosis of malaria in this region.
Nguyen, Shon; Ramos, Artur; Chang, Joy; Li, Bin; Shanmugam, Vedapuri; Boeras, Debrah; Nkengasong, John N; Yang, Chunfu; Ellenberger, Dennis
2015-04-01
HIV-1 viral load (VL) levels are used for monitoring disease progression and antiretroviral therapy outcomes in HIV-infected patients. To assess the performance of laboratories conducting HIV-1 VL testing in resource-limited settings, the U.S. Centers for Disease Control and Prevention implemented a voluntary, free-of-charge, external quality assurance program using dried tube specimens (DTSs). Between 2010 and 2012, DTS proficiency testing (PT) panels consisting of 5 specimens were distributed at ambient temperature to participants. The results from the participants (n≥6) using the same assay were grouped, analyzed, and graded as acceptable within a group mean±3 standard deviations. Mean proficiency scores were calculated by dividing the combined PT scores by the number of testing cycles using a linear regression model. Between 2010 and 2012, the number of participants enrolled increased from 32 in 16 countries to 114 in 44 countries. A total of 78.2% of the participants reported results using 10 different VL assays. The rates of reporting of acceptable results by the participants were 96.6% for the Abbott assay, 96.3% for the Roche Cobas assay, 94.5% for the Roche Amplicor assay, 93.0% for the Biocentric assay, and 89.3% for the NucliSens assay. The overall mean proficiency scores improved over time (P=0.024). DTSs are a good alternative specimen type to plasma specimens for VL PT programs, as they do not require cold chain transportation and can be used on PCR-based assays. Our data suggest that the CDC HIV-1 VL PT program using DTSs positively impacts the testing performance of the participants, which might translate into better and more accurate VL testing services for patients. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Method of fission heat flux determination from experimental data
Paxton, Frank A.
1999-01-01
A method is provided for determining the fission heat flux of a prime specimen inserted into a specimen of a test reactor. A pair of thermocouple test specimens are positioned at the same level in the holder and a determination is made of various experimental data including the temperature of the thermocouple test specimens, the temperature of bulk water channels located in the test holder, the gamma scan count ratios for the thermocouple test specimens and the prime specimen, and the thicknesses of the outer clads, the fuel fillers, and the backclad of the thermocouple test specimen. Using this experimental data, the absolute value of the fission heat flux for the thermocouple test specimens and prime specimen can be calculated.
Fracture toughness testing of polymer matrix composites
NASA Technical Reports Server (NTRS)
Grady, Joseph E.
1992-01-01
A review of the interlaminar fracture indicates that a standard specimen geometry is needed to obtain consistent fracture toughness measurements in polymer matrix composites. In general, the variability of measured toughness values increases as the toughness of the material increases. This variability could be caused by incorrect sizing of test specimens and/or inconsistent data reduction procedures. A standard data reduction procedure is therefore needed as well, particularly for the tougher materials. Little work has been reported on the effects of fiber orientation, fiber architecture, fiber surface treatment or interlaminar fracture toughness, and the mechanisms by which the fibers increase fracture toughness are not well understood. The little data that is available indicates that woven fiber reinforcement and fiber sizings can significantly increase interlaminar fracture toughness.
Ostroff, R M; Steaffens, J W
1995-07-01
Agar culture from vaginal swabs is the routine method for diagnosis of maternal Group B Streptococcus (GBS) colonization. Swab specimens are often transported to a clinical laboratory for processing. In these studies, specimen transport was simulated by inoculating swabs with GBS and storing them at selected temperatures and with or without transport medium. The recovery of viable GBS was assessed by agar culture. GBS antigen was detected immunologically with an Optical ImmunoAssay (OIA) method. Swabs that were stored with transport medium harbored viable but rapidly declining numbers of GBS. In contrast, a strong OIA signal was maintained. Recovery of viable GBS organisms declined more quickly when swabs were stored in the absence of transport medium, whereas detection of GBS antigen remained consistent. Both methods were tested for interference from either antibiotics or feminine hygiene products. These compounds inhibited the detection of GBS by culture but had no detrimental effect on the OIA result.
Quantifying the Influence of Lightning Strike Pressure Loading on Composite Specimen Damage
NASA Astrophysics Data System (ADS)
Foster, P.; Abdelal, G.; Murphy, A.
2018-04-01
Experimental work has shown that a component of lightning strike damage is caused by a mechanical loading. As the profile of the pressure loading is unknown a number of authors propose different pressure loads, varying in form, application area and magnitude. The objective of this paper is to investigate the potential contribution of pressure loading to composite specimen damage. This is achieved through a simulation study using an established modelling approach for composite damage prediction. The study examines the proposed shockwave loads from the literature. The simulation results are compared with measured test specimen damage examining the form and scale of damage. The results for the first time quantify the significance of pressure loading, demonstrating that although a pressure load can cause damage consistent with that measured experimentally, it has a negligible contribution to the overall scale of damage. Moreover the requirements for a pressure to create the damage behaviours typically witnessed in testing requires that the pressure load be within a very precise window of magnitude and loading area.
A proposed standard round compact specimen for plane strain fracture toughness testing
NASA Technical Reports Server (NTRS)
Underwood, J. H.; Newman, J. C., Jr.; Seeley, R. R.
1980-01-01
A round, disk-shaped specimen is proposed as a standard test specimen for addition to ASTM Test for Plane-Strain Fracture Toughness of Metallic Materials (E 399-78A). The specimen is diametrically cracked, and loaded in the same way as the existing standard compact specimen. Tests and analyses were performed to verify that the proposed round compact specimen and associated stress intensity factor K solution are appropriate for a standard plane strain fracture toughness test. The use of the round compact specimen for other fracture tests is described.
Standard Methods for Bolt-Bearing Testing of Textile Composites
NASA Technical Reports Server (NTRS)
Portanova, M. A.; Masters, J. E.
1995-01-01
The response of three 2-D braided materials to bolt bearing loading was evaluated using data generated by Boeing Defense and Space Group in Philadelphia, PA. Three test methods, stabilized single shear, unstabilized single shear, and double shear, were compared. In general, these textile composites were found to be sensitive to bolt bearing test methods. The stabilized single shear method yielded higher strengths than the unstabilized single shear method in all cases. The double shear test method always produced the highest strengths but these results may be somewhat misleading. It is therefore recommended that standard material comparisons be made using the stabilized single shear test method. The effects of two geometric parameters, W/D and e/D, were also studied. An evaluation of the effect of the specimen width (W) to hole diameter (D) ratio concluded that bolt bearing responses were consistent with open hole tension results. A W/D ratio of 6 or greater should be maintained. The proximity of the hole to the specimen edge significantly affected strength. In all cases, strength was improved by increasing the ratio of the distance from the hole center to the specimen edge (e) to the hole diameter (D) above 2. An e/D ratio of 3 or greater is recommended.
Evaluation of Heating Methods for Thermal Structural Testing of Large Structures
NASA Technical Reports Server (NTRS)
Daryabeigi, Kamran; Sikora, Joseph G.; Caldwell, Darrell L., Jr.
1998-01-01
An experimental study was conducted to evaluate different heating methods for thermal structural testing of large scale structures at temperatures up to 350 F as part of the High Speed Research program. The heating techniques evaluated included: radiative/convective, forced convective, and conductive. The radiative/convective heaters included finned strip heaters, and clear and frosted quartz lamps. The forced convective heating was accomplished by closed loop circulation of heated air. The conductive heater consisted of heating blankets. The tests were conducted on an 1/8 inch thick stainless steel plate in a custom-built oven. The criteria used for comparing the different heating methods included test specimen temperature uniformity, heater response time, and consumed power. The parameters investigated included air circulation in the oven, reflectance of oven walls, and the orientation of the test specimen and heaters (vertical and horizontal). It was found that reflectance of oven walls was not an important parameter. Air circulation was necessary to obtain uniform temperatures only for the vertically oriented specimen. Heating blankets provided unacceptably high temperature non-uniformities. Quartz lamps with internal air circulation had the lowest power consumption levels. Using frosted quartz lamps with closed loop circulation of cool air, and closed loop circulation of heated air provided the fastest response time.
Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Izopet, Jacques; Lombardi, Alessandra; Marcos, MaAngeles; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel
2017-10-01
Hepatitis B viral load testing is essential to treatment and monitoring decisions in patients with chronic Hepatitis B. Beckman Coulter has developed the VERIS HBV Assay (Veris) for use on the fully automated DxN VERIS Molecular Diagnostics System. 1 OBJECTIVES: To evaluate the clinical performance of the Veris HBV Assay at multiple EU laboratories STUDY DESIGN: Method comparison was performed with a total of 344 plasma specimens from HBV infected patients tested with Veris and COBAS ® TaqMan ® HBV Test (Cobas), 207 specimens tested with Veris and RealTime HBV Assay (RealTime), 86 specimens tested with Veris and VERSANT ® HBV Assay (Versant), and 74 specimens tested with Veris and artus ® HBV RG PCR kit (artus). Bland-Altman analysis showed average bias of -0.46 log 10 IU/mL between Veris and Cobas, -0.46 log 10 IU/mL between Veris and RealTime, -0.36 log 10 IU/mL between Veris and Versant, and -0.12 log 10 IU/mL between Veris and artus. Bias was consistent across the assay range. Patient monitoring results using Veris demonstrated similar viral load trends over time to Cobas, RealTime, and artus. The VERIS HBV Assay demonstrated comparable clinical performance, with varying degrees of negative bias, compared to other currently marketed assays for HBV DNA monitoring. This negative bias should be taken into consideration if switching monitoring methods to Veris. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Li, Jian; Lee, Edward W.; OBrien, T. Kevin; Lee, Shaw Ming
1996-01-01
An analytical and experimental investigation was carried out on G40-800/R6376 graphite epoxy laminates to evaluate the Edge Crack Torsion (ECT) test as a candidate for a standard Mode 3 interlaminar fracture toughness test for laminated composites. The ECT test consists of a (90/(+/- 45)(sub 3)/(+/- 45)(sub 3)/90))(sub s) laminate with a delamination introduced by a non-adhesive film at the mid-plane along one edge and loaded in a special fixture to create torsion along the length of the laminate. Dye penetrate enhanced X-radiograph of failed specimens revealed that the delamination initiated at the middle of the specimen length and propagated in a self similar manner along the laminate mid-plane. A three-dimensional finite element analysis was performed that indicated that a pure Mode 3 delamination exists at the middle of specimen length away from both ends. At the ends near the loading point a small Mode 2 component exists. However, the magnitude of this Mode 2 strain energy release rate at the loading point is small compared to the magnitude of Mode 3 component in the mid-section of the specimen. Hence, the ECT test yielded the desired Mode 3 delamination. The Mode 3 fracture toughness was obtained from a compliance calibration method and was in good agreement with the finite element results. Mode 2 End-Notched Flexure (ENF) tests and Mode 1 Double Cantilever Beam (DCB) tests were also performed for the same composite material. The Mode 1 fracture toughness was much smaller than both the Mode 2 and Mode 3 fracture toughness. The Mode 2 fracture toughness was found to be 75% of the Mode 3 fracture toughness.
Design, Test, and Acceptance Criteria for Helicopter Transparent Enclosures
1978-11-01
point is a mass center of gravity at a specified station. Flight Path 24 YVertical Acceleration Pitching Acceleration N 2-51g = 1.89 rad/sec 2 Figure 59...rubber wiper blades would otherwise be incapable of abrading ntost windshield meterials . Aaratus The apparatus consisted of a specimen holding fixture
Preliminary test results in support of integrated EPP and SMT design methods development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Yanli; Jetter, Robert I.; Sham, T. -L.
2016-02-09
The proposed integrated Elastic Perfectly-Plastic (EPP) and Simplified Model Test (SMT) methodology consists of incorporating a SMT data-based approach for creep-fatigue damage evaluation into the EPP methodology to avoid using the creep-fatigue interaction diagram (the D diagram) and to minimize over-conservatism while properly accounting for localized defects and stress risers. To support the implementation of the proposed code rules and to verify their applicability, a series of thermomechanical tests have been initiated. One test concept, the Simplified Model Test (SMT), takes into account the stress and strain redistribution in real structures by including representative follow-up characteristics in the test specimen.more » The second test concept is the two-bar thermal ratcheting tests with cyclic loading at high temperatures using specimens representing key features of potential component designs. This report summaries the previous SMT results on Alloy 617, SS316H and SS304H and presents the recent development on SMT approach on Alloy 617. These SMT specimen data are also representative of component loading conditions and have been used as part of the verification of the proposed integrated EPP and SMT design methods development. The previous two-bar thermal ratcheting test results on Alloy 617 and SS316H are also summarized and the new results from two bar thermal ratcheting tests on SS316H at a lower temperature range are reported.« less
Thermal insulation testing method and apparatus
NASA Technical Reports Server (NTRS)
Fesmire, James E. (Inventor); Augustynowicz, Stanislaw D. (Inventor)
2004-01-01
A test apparatus and method of its use for evaluating various performance aspects of a test specimen is disclosed. A chamber within a housing contains a cold mass tank with a contact surface in contact with a first surface of a test specimen. The first surface of the test specimen is spaced from the second surface of the test specimen by a thickness. The second surface of the test specimen is maintained at a desired warm temperature. The first surface is maintained at a constant temperature by a liquid disposed within the cold mass tank. A boil-off flow rate of the gas is monitored and provided to a processor along with the temperature of the first and second surfaces of the test specimen. The processor calculates thermal insulation values of the test specimen including comparative values for heat flux and apparent thermal conductivity (k-value). The test specimen may be placed in any vacuum pressure level ranging from about 0.01 millitorr to 1,000,000 millitorr with different residual gases as desired. The test specimen may be placed under a mechanical load with the cold mass tank and another factors may be imposed upon the test specimen so as to simulate the actual use conditions.
Thermal Insulation Testing Method and Apparatus
NASA Technical Reports Server (NTRS)
Fesmire, James E. (Inventor); Augustynowicz, Stanislaw D. (Inventor)
2004-01-01
A test apparatus and method of its use for evaluating various performance aspects of a test specimen is disclosed. A chamber within a housing contains a cold mass tank with a contact surface in contact with a first surface of a test specimen. The first surface of the test specimen is spaced from the second surface of the test specimen by a thickness. The second surface of the test specimen is maintained at a a constant temperature by a liquid disposed within the cold mass tank. A boil-off flow rate of the gas is monitored and provided to a processor along with the temperature of the first and second surfaces of the test specimen. The processor calculates thermal insulation values of the test specimen including comparative values for heat flux and apparent thermal conductivity k-value). The test specimen may be placed in any vacuum pressure level ranging from about 0.01 millitorr to 1,000,000 millitorr with different residual gases as desired. The test specimen may be placed under a mechanical load with the cold mass tank and another factors may be imposed upon the test specimen so as to simulate the actual use conditions.
Reliability Analysis of Uniaxially Ground Brittle Materials
NASA Technical Reports Server (NTRS)
Salem, Jonathan A.; Nemeth, Noel N.; Powers, Lynn M.; Choi, Sung R.
1995-01-01
The fast fracture strength distribution of uniaxially ground, alpha silicon carbide was investigated as a function of grinding angle relative to the principal stress direction in flexure. Both as-ground and ground/annealed surfaces were investigated. The resulting flexural strength distributions were used to verify reliability models and predict the strength distribution of larger plate specimens tested in biaxial flexure. Complete fractography was done on the specimens. Failures occurred from agglomerates, machining cracks, or hybrid flaws that consisted of a machining crack located at a processing agglomerate. Annealing eliminated failures due to machining damage. Reliability analyses were performed using two and three parameter Weibull and Batdorf methodologies. The Weibull size effect was demonstrated for machining flaws. Mixed mode reliability models reasonably predicted the strength distributions of uniaxial flexure and biaxial plate specimens.
Evaluation of Repair Efficiency in Structures Made of Fibrous Polymer Composite Materials
NASA Astrophysics Data System (ADS)
Anoshkin, A. N.; Vil'deman, V. E.; Lobanov, D. S.; Chikhachev, A. I.
2014-07-01
Full-scale experimental investigations into the residual strength of structurally similar elements of acoustical panels after a local repair of defects, such as through breakdown, were conducted. Local repairs without using the vacuum technology were carried out. The technology of repair consists in removing and layer-bylayer replacing the damaged layers of material with repaired ones. For comparison, undamaged and repaired sandwich panel specimens were tested in tension and compression. The specimens were produced by serial technology from a VPS-33 fiberglass prepreg. Their deformation and fracture mechanisms are analyzed, and their loading diagrams are obtained.
Fatigue Investigation of the E-2B/C Nose Landing Gear
1975-12-31
Specimen - Outer Cylinder and Caster Barrel 9 3 E-2B NLG Test Specimen - Drag Brace 10 4 E-2B NLG Drag Brace Attachment Lugs Modification . . 11 5...Attachment Lug Fracture Surface . . 23 ■■■■ ? 16 Tow Link Modification 30 17 Tow Link #2 Failur 31 18 Tow Link #2 Fracture Face 32 19...34-" ’’- .-.„.,.,„...^ ,.., M1| lf^^~i*>-^^-^^ "u- II li ’ 7«™.™»«*" ■ NADC-75369-30 Bach «hock «true assembly consist« of the «xle- caster barrel, outer cylinder
Mechanical behaviour of cerclage material consisting of silicon rubber.
Hinrichsen, G; Eberhardt, A; Springer, H
1979-09-01
Silicon rubber specimens of circular or rectangular cross-section (cross-section area between ca. 2 and 7 mm2) are used as cerclage bands. A series of commercial cerclage elements was investigated for mechanical characteristics, such as stress-strain behaviour and modulus of elasticity, using a tensile-testing machine. Large differences in these properties exist among the various specimens. Moreover, time-dependent effects, such as stress-relaxation, retardation, and creep, were analysed by the present investigations. One has to take into consideration that the initial length and stress of the cerclage band vary significantly with time after the operation.
Teti, G; Burdash, N M; Zamboni, C; Fava, C; Tomasello, F; Mastroeni, P
1984-01-01
A new commercial method intended to exclude the presence of Salmonella spp., Shigella spp., and Yersinia enterocolitica and to presumptively identify Salmonella isolates within 2 h after primary isolation from stool specimens was evaluated. This system is marketed in Europe as API Z and in the United States as Rapid SST. The strip consists of five pairs of cupules for the screening of five lactose-negative colonies. The first cupule of each pair detects the presence of five enzymatic activities, whereas the second serves to maintain the strain for additional testing if necessary. A total of 197 fresh isolates from stool specimens and 217 stock cultures of Salmonella spp., Shigella spp., and Yersinia enterocolitica were tested, with the API 20E system as a reference method. In the stool specimens, 77.3% of the bacteria could be excluded from further workup for the presence of these organisms within 2 h. Over 97% of the stock strains and each of three fresh Salmonella isolates tested produced a reaction pattern corresponding to a correct presumptive identification. This reaction pattern was not produced by any isolate other than the Salmonella isolates. The API Z system can be used as a screen for the presence of Salmonella and Shigella spp. and can provide an accurate presumptive identification of Salmonella isolates within 2 h after primary isolation. PMID:6394610
NASA Technical Reports Server (NTRS)
James, Mark; Wells, Doug; Allen, Phillip; Wallin, Kim
2017-01-01
Recently proposed modifications to ASTM E399 would provide a new size-insensitive approach to analyzing the force-displacement test record. The proposed size-insensitive linear-elastic fracture toughness, KIsi, targets a consistent 0.5mm crack extension for all specimen sizes by using an offset secant that is a function of the specimen ligament length. The KIsi evaluation also removes the Pmax/PQ criterion and increases the allowable specimen deformation. These latter two changes allow more plasticity at the crack tip, prompting the review undertaken in this work to ensure the validity of this new interpretation of the force-displacement curve. This paper provides a brief review of the proposed KIsi methodology and summarizes a finite element study into the effects of increased crack tip plasticity on the method given the allowance for additional specimen deformation. The study has two primary points of investigation: the effect of crack tip plasticity on compliance change in the force-displacement record and the continued validity of linear-elastic fracture mechanics to describe the crack front conditions. The analytical study illustrates that linear-elastic fracture mechanics assumptions remain valid at the increased deformation limit; however, the influence of plasticity on the compliance change in the test record is problematic. A proposed revision to the validity criteria for the KIsi test method is briefly discussed.
Double Cantilever Beam Fracture Toughness Testing of Several Composite Materials
NASA Technical Reports Server (NTRS)
Kessler, Jeff A.; Adams, Donald F.
1992-01-01
Double-cantilever beam fracture toughness tests were performed by the Composite Materials Research Group on several different unidirectional composite materials provided by NASA Langley Research Center. The composite materials consisted of Hercules IM-7 carbon fiber and various matrix resin formulations. Multiple formulations of four different families of matrix resins were tested: LaRC - ITPI, LaRC - IA, RPT46T, and RP67/RP55. Report presents the materials tested and pertinent details supplied by NASA. For each material, three replicate specimens were tested. Multiple crack extensions were performed on each replicate.
NASA Astrophysics Data System (ADS)
Dicecco, Sante; Altenhof, William; Hu, Henry; Banting, Richard
2017-04-01
In an effort to better understand the impact of material degradation on the fatigue life of mining wheels made of a high-strength low alloy carbon steel (Q345), this study seeks to evaluate the effect of surface corrosion on the high-cycle fatigue behavior of the Q345 alloy. The fatigue behavior of the polished and corroded alloy was investigated. Following exposure to a 3.5 wt.% NaCl saltwater solution, polished and corroded fatigue specimens were tested using an R.R. Moore rotating-bending fatigue apparatus. Microstructural analyses via both optical microscopy and scanning electron microscopy (SEM) revealed that one major phase, α-iron phase, ferrite, and one minor phase, colony pearlite, existed in the extracted Q345 alloy. The results of the fatigue testing showed that the polished and corroded specimens had an endurance strength of approximately 295 and 222 MPa, respectively, at 5,000,000 cycles. The corroded surface condition resulted in a decrease in the fatigue strength of the Q345 alloy by 24.6%. Scanning electron microscope fractography indicated that failure modes for polished and corroded fatigue specimens were consistent in the high-cycle low loading fatigue regime. Conversely, SEM fractography of low-cycle high-loading fatigue specimens found considerable differences in fracture surfaces between the corroded and polished fatigue specimens.
Strengthening of defected beam-column joints using CFRP.
Mahmoud, Mohamed H; Afefy, Hamdy M; Kassem, Nesreen M; Fawzy, Tarek M
2014-01-01
This paper presents an experimental study for the structural performance of reinforced concrete (RC) exterior beam-column joints rehabilitated using carbon-fiber-reinforced polymer (CFRP). The present experimental program consists of testing 10 half-scale specimens divided into three groups covering three possible defects in addition to an adequately detailed control specimen. The considered defects include the absence of the transverse reinforcement within the joint core, insufficient bond length for the beam main reinforcement and inadequate spliced implanted column on the joint. Three different strengthening schemes were used to rehabilitate the defected beam-column joints including externally bonded CFRP strips and sheets in addition to near surface mounted (NSM) CFRP strips. The failure criteria including ultimate capacity, mode of failure, initial stiffness, ductility and the developed ultimate strain in the reinforcing steel and CFRP were considered and compared for each group for the control and the CFRP-strengthened specimens. The test results showed that the proposed CFRP strengthening configurations represented the best choice for strengthening the first two defects from the viewpoint of the studied failure criteria. On the other hand, the results of the third group showed that strengthening the joint using NSM strip technique enabled the specimen to outperform the structural performance of the control specimen while strengthening the joints using externally bonded CFRP strips and sheets failed to restore the strengthened joints capacity.
Shokouhi, Parisa; Rivière, Jacques; Lake, Colton R; Le Bas, Pierre-Yves; Ulrich, T J
2017-11-01
The use of nonlinear acoustic techniques in solids consists in measuring wave distortion arising from compliant features such as cracks, soft intergrain bonds and dislocations. As such, they provide very powerful nondestructive tools to monitor the onset of damage within materials. In particular, a recent technique called dynamic acousto-elasticity testing (DAET) gives unprecedented details on the nonlinear elastic response of materials (classical and non-classical nonlinear features including hysteresis, transient elastic softening and slow relaxation). Here, we provide a comprehensive set of linear and nonlinear acoustic responses on two prismatic concrete specimens; one intact and one pre-compressed to about 70% of its ultimate strength. The two linear techniques used are Ultrasonic Pulse Velocity (UPV) and Resonance Ultrasound Spectroscopy (RUS), while the nonlinear ones include DAET (fast and slow dynamics) as well as Nonlinear Resonance Ultrasound Spectroscopy (NRUS). In addition, the DAET results correspond to a configuration where the (incoherent) coda portion of the ultrasonic record is used to probe the samples, as opposed to a (coherent) first arrival wave in standard DAET tests. We find that the two visually identical specimens are indistinguishable based on parameters measured by linear techniques (UPV and RUS). On the contrary, the extracted nonlinear parameters from NRUS and DAET are consistent and orders of magnitude greater for the damaged specimen than those for the intact one. This compiled set of linear and nonlinear ultrasonic testing data including the most advanced technique (DAET) provides a benchmark comparison for their use in the field of material characterization. Copyright © 2017 Elsevier B.V. All rights reserved.
Hashikita, Giichi; Yamaguti, Toshiyuki; Tachi, Yoshimi; Kishi, Etsuko; Kawamura, Toru; Takahashi, Shun; Arai, Yukie; Koyama, Sachie; Huruhata, Toshihumi; Itabashi, Akira; Oka, Yoko; Yamazaki, Tsutomu; Maesaki, Sigefumi
2005-01-01
We investigated the usefullness of Binax NOW urine antigen test, an immunochromatographic assay that binds any soluble Streptococcus pneumoniae antigen (C polysaccharide) for the diagnosis of penumoniae form September 2003 to March 2005. We used 372 samples form the patinets with pneumoniae diagnosed for blood or sputum cultuter or gram-stained sputum smear. Out of 24 culture positive specimens, Binax NOW urine antigen test, showed positive in 18 (75%) specimens. The sensitivity of sputum and blood culture was 71.7% and 83.3%, respectively. Binax NOW urine antigen test was seemed false positives in 55 samples, false negatives in 6 samples. The specificity of Binax NOW urine antigen test was evaluated 84.1%. Overall agreement among tests was 83.6%. When compared to culture, false negative urine antigen may be the result of colonizing S. pneumoniae in sputum or pneumonia caused by an agent other than S. pneumoniae. CRP values for cases were both urine antigen and culture were positive ranged from 40 mg/dl to 10 mg/dl while urine antigen and culture negative cases were predominantly less than 10 mg/dl. Positive blood and pleural fluid culture cases were consistently associated with strongly positive urine antigen tests. Non-agreement between urine antigen, culture, and microscopy may be the result of specimen quality, labile nature of S. pneumoniae and antimicrobial therapy.
NASA Technical Reports Server (NTRS)
Diaz, J. O.
1985-01-01
Composites consisting of tungsten alloy wires in superalloy matrices are being studied because they offer the potential for increased strength compared to current materials used at temperatures up to at least 1093 C (2000F). Previous research at the NASA Lewis Research Center and at other laboratories in the U.S., Europe, and Japan has demonstrated laboratory feasibility for fiber reinforced superalloys (FRS). The data for the mechanical and physical properties used to evaluate candidate materials is limited and a need exists for a more detailed and complete data base. The focus of this work is to develop a test procedure to provide a more complete FRS data base to quantitatively evaluate the composite's potential for component applications. This paper will describe and discuss the equipment and procedures under development to obtain elevated temperature tensile stress-strain, strength and modulus data for the first generation of tungsten fiber reinforced superalloy composite (TFRS) materials. Tensile stress-strain tests are conducted using a constant crosshead speed tensile testing machine and a modified load-strain measuring apparatus. Elevated temperature tensile tests are performed using a resistance wound commercial furnace capable of heating test specimens up to 1093 C (2000 F). Tensile stress-strain data are obtained for hollow tubular stainless steel specimens serving as a prototype for future composite specimens.
Physical properties of pressurized sediment from hydrate ridge
Winters, William J.; Waite, William F.; Mason, David H.; Gilbert, Lauren
2006-01-01
As part of an ongoing laboratory study, preliminary acoustic, triaxial strength, and electrical resistivity results are presented from a test performed on a clayey silt sediment sample recovered from Site 1249 at the summit of southern Hydrate Ridge during Ocean Drilling Program Leg 204. The test specimen was stored and transported in two different methane-charged pressure vessels until it was tested using the Gas Hydrate and Sediment Test Laboratory Instrument (GHASTLI). Although gas hydrate may have existed in the core section immediately after recovery, little (if any) hydrate was present in the specimen during testing. We therefore present background physical property results for sediment that may have hosted gas hydrate in situ. Because we consolidated the test specimen in increments beyond its in situ stress state, we are able to present properties representative of similar but deeper subbottom sediment. The increased consolidation stress also helped to mitigate some, but not all, types of disturbance caused by the recovery process. P-wave velocities from 1.54 to 1.74 km/s varied linearly with consolidation stress, σ′c, up to 970 kPa (equivalent to ~160 meters below seafloor). Electrical resistivity was periodically measured by a Wenner array and varied between 1.0 and 2.8 Ωm. These values reflect both the pore water salinity and soft, fine-grained texture of the sediment. Shear behavior is consistent with the induced normally consolidated behavior of clayey silt.
Production of ultrafine grained aluminum by cyclic severe plastic deformation at ambient temperature
NASA Astrophysics Data System (ADS)
Bereczki, P.; Szombathelyi, V.; Krallics, G.
2014-08-01
In the present study the possibilities of grain refinement was investigated by applying large-scale of cyclic plastic deformation to aluminum at ambient temperature. The specimens are processed by multiaxial forging, which is one of the severe plastic deformation techniques. The aim of the experiments with the aluminum alloy 6082M was the determination of the equivalent stress and strain by multiaxial forging and the investigation of evolution of mechanical properties in relation with the accumulated deformation in the specimen. The mechanical properties of raw material was determined by plane strain compression test as well as by hardness measurements. The forming experiments were carried out on Gleeble 3800 physical simulator with MaxStrain System. The mechanical properties of the forged specimens were investigated by micro hardness measurements and tensile tests. A mechanical model, based on the principle of virtual velocities was developed to calculate the flow curves using the measured dimensional changes of the specimen and the measured force. With respect to the evolution of these curves, the cyclic growth of the flow stress can be observed at every characteristic points of the calculated flow curves. In accordance with this tendency, the evolution of the hardness along the middle cross section of the deformed volume has also a nonmonotonous characteristic and the magnitudes of these values are much smaller than by the specimen after plane strain compression test. This difference between the flow stresses respect to the monotonic and non-monotonic deformation can be also observed. The formed microstructure, after a 10-passes multiaxial forging process, consists of mainly equiaxial grains in the submicron grain scale.
Van Der Pol, Barbara; Quinn, Thomas C.; Gaydos, Charlotte A.; Crotchfelt, Kimberly; Schachter, Julius; Moncada, Jeanne; Jungkind, D.; Martin, David H.; Turner, Buffy; Peyton, Cynthia; Jones, Robert B.
2000-01-01
The fully automated COBAS AMPLICOR CT/NG and semiautomated AMPLICOR CT/NG tests were evaluated in a multicenter trial for the ability to detect Chlamydia trachomatis infections. Test performance compared to that of culture was evaluated for 2,236 matched endocervical swab and urine specimens obtained from women and for 1,940 matched urethral swab and urine specimens obtained from men. Culture-negative, PCR-positive specimens that tested positive in a direct fluorescent-antibody test or in a confirmatory PCR test for an alternative target sequence were resolved as true positives. The overall prevalences of chlamydia were 2.4% in women and 7.2% in men. The COBAS AMPLICOR and AMPLICOR formats yielded concordant results for 98.1% of the specimens. With the infected patient as the reference standard, the resolved sensitivities of COBAS AMPLICOR were 89.7% for endocervical swab specimens, 89.2% for female urine specimens, 88.6% for male urethral swab specimens, and 90.3% for male urine specimens. When results were analyzed as if only a single test had been performed on a single specimen type, the resolved sensitivity was always higher. The resolved specificities of PCR were 99.4% for endocervical swab specimens, 99.0% for female urine specimens, 98.7% for male urethral swab specimens, and 98.4% for male urine specimens. The internal control revealed that 2.4% of the specimens were inhibitory when initially tested. Nevertheless, valid results were obtained for 98.6% of the specimens because 59.1% of the inhibitory specimens were not inhibitory when a second aliquot was tested. The COBAS AMPLICOR and AMPLICOR CT/NG tests for C. trachomatis exhibited equally high sensitivity and specificity with both urogenital swab and urine specimens and thus are well suited for screening for C. trachomatis infection. PMID:10699004
Scale-Up of an Human Papillomavirus Testing Implementation Program in El Salvador.
Cremer, Miriam; Maza, Mauricio; Alfaro, Karla; Morales Velado, Mario; Felix, Juan; Castle, Philip E; Kim, Jane; Gage, Julia C
2017-01-01
The Cervical Cancer Prevention in El Salvador is a demonstration project to introduce a lower-cost human papillomavirus (HPV)-DNA test into a public sector project. Started in October 2012, The Cervical Cancer Prevention in El Salvador consists of 3 phases and will ultimately screen 30,000 women. Results of phase 2 of the project are presented. The objective of this project was to compare colposcopy and noncolposcopy-based management for HPV-positive women. In phase 2, a total of 8,050 women, aged 30 to 49 years, were screened; 6,761 provided both self- and provider-collected specimens and 1,289 provided only provider-testing specimens. HPV results from self-collected specimens were not used in clinical management decisions. Women with provider-collected HPV-positive results were treated based on the strategy assigned to their community; the strategy was colposcopy management (CM) or screen-and-treat (ST) management if they were cryotherapy eligible or colposcopy if not eligible. Outcomes were assessed 6 months after screening. Overall, 489 (12.3%) of 3,963 women receiving CM and 465 (11.4%) of 4,087 women receiving ST tested HPV positive. In the CM cohort, 216 (44.2%) of 489 completed their intervention (203 treated, 11 diagnosed negative, 2 pregnant). In the ST cohort, 411 (88.4%) of 465 completed their intervention (407 treated, 2 diagnosed negative, 1 pregnant). Overall agreement between HPV test results from self-collected and provider-collected specimens was 93.7%, with a κ value of 0.70 (95% CI = 0.68-0.73). Human papillomavirus testing with ST management resulted in an approximately twice completion rate compared with CM management. Agreement between self- and provider-based sampling was good and might be used to extend screening to women in areas that are more difficult to reach.
Impact Deformation of Thin-Walled Circular Tube Filled with Aluminum Foam in Lateral Compression
NASA Astrophysics Data System (ADS)
Kobayashi, Hidetoshi; Horikawa, Keitaro; Ogawa, Kinya; Hori, Masahiro
In this study, the impact deformation of thin-walled circular tubes filled with aluminum foam in lateral compression was investigated using a special load cell for long time measurement and a high-speed video camera to check the displacement of specimens. It was found that the absorbed energy up to the deformation of 60% of the specimen diameter obtained from impact tests is greater than that obtained in static tests, because of strain rate dependency of aluminum foam. The loaddisplacement curve of circular tubes with aluminum foam just inserted was consistent with the sum of the curves individually obtained. In both dynamic and static tests, however, the load of the tube with the foam inserted and glued by adhesive resin became larger than the sum of the individual loads, because of the interaction between circular tubes and aluminum foam cores.
In vitro resistance to fracture of roots obturated with Resilon or gutta-percha.
Monteiro, Jeanne; de Ataide, Ida de Noronha; Chalakkal, Paul; Chandra, Pavan Kumar
2011-06-01
There have been varied results from studies comparing postendodontic fracture resistance between teeth obturated with Resilon or gutta-percha. This study was performed to evaluate the fracture resistance of roots obturated by using Resilon (RealSeal system) or gutta-percha (with AH Plus sealer). Eighty extracted human mandibular single-rooted premolars stored in 10% formalin were used in the study. They were prepared by using a crown-down technique, debrided with NaOCl, ethylenediaminetetraacetic acid, and sterile water and divided into 4 groups. Obturation was performed by using the lateral condensation method. The negative control group consisted of unfilled specimens, and the positive control group consisted of those obturated with flowable, dual-cure composite resin. All root specimens were stored for 2 weeks in 100% humidity to allow complete setting of the sealer. Each specimen was mounted in acrylic in a polyvinyl ring and tested for fracture resistance with the Universal testing machine. The loading fixture of the machine was mounted with its spherical tip aligned with the center of the canal opening of each root. A vertical loading force was applied until it fractured the root. The force values were subjected to statistical analysis including analysis of variance and Fisher least significant difference testing. Teeth obturated with Resilon were more resistant to fracture than those obturated with gutta-percha. The difference was found to be highly significant (P=.00001). Resilon increased the resistance to fracture of single-rooted teeth in vitro. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Behavior of fragmentation front in a porous viscoelastic material
NASA Astrophysics Data System (ADS)
Ichihara, M.; Takayama, K.
2002-12-01
We are developing laboratory experiments to investigate dynamics of magma fragmentation during explosive volcanic eruptions. Fragmentation of such a mixture as magma consisting of viscoelastic melt, bubbles and solid particles, is not known yet, and experiments are necessary to establish a mathematical model. It has been shown that viscoelastic silicone compound (Dow Corning 3179) is a useful analogous material to simulate magma fragmentation. In the previous work, a porous specimen made of the compound was rapidly decompressed and development of brittle fragmentation was observed. However, there were arguments that the experiment was different from actual processes which produce fragments as small as volcanic ash, because in the experiment the specimen was broken into only several pieces. This time, results of the improved experiments are presented. The experimental apparatus is a kind of a vertical shock tube, which mainly consists of a high pressure test section and low pressure chambers. The test section is made of acrylic tube of which inner diameter is 25 mm. The internal phenomenon is recorded by a high-speed video camera. Pressure is measured in the gas above and beneath the specimen by piezoelectric transducers. The specimen is prepared in the following way. First, an acrylic tube filled with the compound is put in a nitrogen tank and kept at 45 bar for more than 8 hours. The compound absorbs the gas and equilibrates with the nitrogen. Next, the tank is decompressed back to the atmospheric pressure slowly. Nitrogen exsolves and bubbles are formed in the compound quite uniformly. Finally, the expanded compound sticking out of both ends of the tube is cut down, and the tube containing the specimen is attached to the shock tube. The specimen is rapidly decompressed by 24, 16, and 8 bars. The high-speed video images demonstrate a sequence of the fragmentation process. We observe propagation of a clear fracture front at 50 m/s for 24 bar of decompression and at smaller speed for smaller decompression. The pressure change associated with development of the fragmentation is analyzed and effects of over pressure in the pores and permeable gas flow on fragmentation behavior are discussed.
NASA Technical Reports Server (NTRS)
Jacobs, Jeremy B.; Castner, Willard L.
2007-01-01
A viewgraph presentation describing cracks and failure analysis of an orbiter reaction control system is shown. The topics include: 1) Endeavour STS-113 Landing; 2) RCS Thruster; 3) Thruster Cross-Section; 4) RCS Injector; 5) RCS Thruster, S/N 120l 6) Counterbore Cracks; 7) Relief Radius Cracks; 8) RCS Thruster Cracking History; 9) Thruster Manufacturing Timelines; 10) Laboratory Reproduction of Injector Cracking; 11) The Brownfield Specimen; 12) HF EtchantTests/Specimen Loading; 13) Specimen #3 HF + 600F; 14) Specimen #3 IG Fracture; 15) Specimen #5 HF + 600F; 16) Specimen #5 Popcorn ; 17) Specimen #5 Cleaned and Bent; 18) HF Exposure Test Matrix; 19) Krytox143AC Tests; 20) KrytoxTests/Specimen Loading; 21) Specimen #13 Krytox + 600F; and 22) KrytoxExposure Test Matrix.
NASA Technical Reports Server (NTRS)
Fetheroff, C. W.; Derkacs, T.; Matay, I. M.
1979-01-01
An automated plasma spray (APS) process was developed to apply two layer (NiCrAlY and ZrO2-12Y2O3) thermal-barrier coatings to aircraft gas turbine engine blade airfoils. The APS process hardware consists of four subsystems: a mechanical blade positioner incorporating two interlaced six-degree-of-freedom assemblies; a noncoherent optical metrology subsystem; a microprocessor-based adaptive system controller; and commercial plasma spray equipment. Over fifty JT9D first stage turbine blades specimens were coated with the APS process in preliminary checkout and evaluation studies. The best of the preliminary specimens achieved an overall coating thickness uniformity of + or - 53 micrometers, much better than is achievable manually. Factors limiting this performance were identified and process modifications were initiated accordingly. Comparative evaluations of coating thickness uniformity for manually sprayed and APS coated specimens were initiated. One of the preliminary evaluation specimens was subjected to a torch test and metallographic evaluation.
Ianuzzi, Allyson; Pickar, Joel G; Khalsa, Partap S
2009-01-01
Quadruped animal models have been validated and used as biomechanical models for the lumbar spine. The biomechanics of the cat lumbar spine has not been well characterized, even though it is a common model used in neuromechanical studies. Compare the physiological ranges of motion and determine torque-limits for cat and human lumbar spine specimens during physiological motions. Biomechanics study. Cat and human lumbar spine specimens. Intervertebral angle (IVA), joint moment, yield point, torque-limit, and correlation coefficients. Cat (L2-sacrum) and human (T12-sacrum) lumbar spine specimens were mechanically tested to failure during displacement-controlled extension (E), lateral bending (LB), and axial rotation (AR). Single trials consisted of 10 cycles (10mm/s or 5 degrees /s) to a target displacement where the magnitude of the target displacement was increased for subsequent trials until failure occurred. Whole-lumbar stiffness, torque at yield point, and joint stiffness were determined. Scaling relationships were established using equations analogous to those that describe the load response of elliptically shaped beams. IVA magnitudes for cat and human lumbar spines were similar during physiological motions. Human whole-lumbar and joint stiffness magnitudes were significantly greater than those for cat spine specimens (p<.05). Torque-limits were also greater for humans compared with cats. Scaling relationships with high correlation (R(2) greater than 0.77) were established during later LB and AR. The current study defined "physiological ranges of movement" for human and cat lumbar spine specimens during displacement-controlled testing, and should be observed in future biomechanical studies conducted under displacement control.
Mechanical Properties of Ceramics for High Temperature Applications
1976-12-01
difficult so far. Also torsion creep tests have been performed /2 /, not considered in this figure. The data show a relatively consistent picture...mittent creep test. Corrosion effects are claimed to be operative during fatigue : The lifetime of a fa- tigue specimen, being controlled by the slow...of plot at extremely low rates of loading. The static fatigue limit on this type of plot is the strength below which there is no effect of loading
Wang, Shu; Yu, Bing; Ng, Chiu Chin; Mercorella, Belinda; Selinger, Christina I.; O’Toole, Sandra A.
2015-01-01
Background Patients with advanced non-small cell lung cancer (NSCLC) benefit from treatment with epidermal growth factor receptor (EGFR) tyrosine kinase inhibitors (TKIs) when their tumor harbors an activating EGFR mutation. As the majority of NSCLC patients present with advanced disease, cytology and small biopsy specimens are frequently the only tissue available for mutation testing, but can pose challenges due to low tumor content. We aim to better define the suitability of these specimens for mutation testing. Methods NSCLC cases referred to our institution for mutation testing over a 15-month period were retrospectively reviewed. Specimens were tested for mutations including EGFR, KRAS, and BRAF, using a multiplex PCR assay (OncoCarta Panel v1.0) and analyzed on the Agena Bioscience MassARRAY platform. Results A total of 146 specimens were tested, comprising 53 (36.3%) resection specimens (including 28 lung resection specimens), 55 (37.7%) small biopsy specimens and 38 (26%) cytology specimens. Of 142 cases with sufficient DNA for mutation testing, EGFR mutations were detected in 31 specimens (21.8%), KRAS mutations in 31 specimens (21.8%) and BRAF mutations in three specimens (2.1%). There was no significant difference in the EGFR mutation rate between lung resection (10 of 28 cases; 35.7%), small biopsy (9 of 53 cases; 17%), and cytology specimens (8 of 36 cases; 22.2%). Conclusions Our results support the utility of small biopsy and cytology specimens for mutation testing. Careful evaluation of the adequacy of small specimens is required to minimize the risk of false negative or positive results. PMID:25870794
Zhou, Fang; Moreira, Andre L
2016-12-01
- In the burgeoning era of molecular genomics, immunoperoxidase (IPOX) testing grows increasingly relevant as an efficient and effective molecular screening tool. Patients with lung carcinoma may especially benefit from the use of IPOX because most lung carcinomas are inoperable at diagnosis and only diagnosed by small tissue biopsy or fine-needle sampling. When such small specimens are at times inadequate for molecular testing, positive IPOX results still provide actionable information. - To describe the benefits and pitfalls of IPOX in the detection of biomarkers in lung carcinoma cytology specimens and small biopsies by summarizing the currently available commercial antibodies, preanalytic variables, and analytic considerations. - PubMed. - Commercial antibodies exist for IPOX detection of aberrant protein expression due to EGFR L858R mutation, EGFR E746_A750 deletion, ALK rearrangement, ROS1 rearrangement, and BRAF V600E mutation, as well as PD-L1 expression in tumor cells. Automated IPOX protocols for ALK and PD-L1 detection were recently approved by the Food and Drug Administration as companion diagnostics for targeted therapies, but consistent interpretive criteria remain to be elucidated, and such protocols do not yet exist for other biomarkers. The inclusion of cytology specimens in clinical trials would expand patients' access to testing and treatment, yet there is a scarcity of clinical trial data regarding the application of IPOX to cytology, which can be attributed to trial designers' lack of familiarity with the advantages and limitations of cytology. The content of this review may be used to inform clinical trial design and advance IPOX validation studies.
Zimmerman, S J; Moses, E; Sofat, N; Bartholomew, W R; Amsterdam, D
1992-01-01
Chlamydia trachomatis diagnosis in our laboratory consisted of dual inoculation of shell vials and detection of inclusions by using fluorescein-conjugated monoclonal antiserum; the second culture vial was conventionally used for blind passage when the first vial was negative. We compared the increase in positivity using blind passage with that of a strategy utilizing observation of two stained monolayers (dual observation) without blind passage, in an effort to reduce the reporting time and labor associated with the conventional approach. A total of 4,329 specimens were obtained from an obstetrics and gynecology (OB-GYN) clinic (2,563 specimens) and the sexually transmitted disease clinic (1,766 specimens). These specimens were used to compare the two strategies. Blind passage of 1,269 initially culture-negative specimens from the OB-GYN clinic resulted in an additional 6 positive chlamydial diagnoses. In comparison, a similar number of specimens (1,294) from the OB-GYN clinic collected subsequently to the first group were tested by dual observation. There were five additional positive findings. A similar evaluation of specimens from the sexually transmitted disease clinic was performed. Blind passage of 313 initially culture-negative specimens yielded 3 additional positive diagnoses, whereas dual observation of 1,435 similar specimens resulted in 9 positive diagnoses. On the basis of analysis of 4,332 specimens, sensitivity of dual observation is comparable to that of blind passage; labor, cost, and reporting time of dual observation are reduced in comparison to those of blind passage. PMID:1452664
Naeem, R C; Goldstein, D Y; Einstein, Mark H; Ramos Rivera, G; Schlesinger, K; Khader, S N; Suhrland, M; Fox, A S
2017-08-01
To compare the cytologic preparations of 130 cervical specimens (from women of various ethnicities at high risk for human papillomavirus [HPV] infection) using the SurePath (SP) collection system with specimens gathered using the ThinPrep (TP) system, as processed on the Cobas 4800 analyzer, to determine which collection method more accurately identifies HPV infection. In our prospective study, specimens were collected from 130 women of various ethnicities residing in or near Bronx County, NY. The SP-collected specimen was first processed for cytologic findings; if clinical HPV testing was requested on that specimen, it was tested using Hybrid Capture II (HC2) methodology. We tested the remnant SP-collected cell concentrate using the Cobas analyzer. Then, the TP-collected and SP-collected specimens were tested in the same run on that analyzer, and the results were compared. We also compared the results with the concurrent cytologic findings. The results were concordant for overall HR-HPV status in 93.8% of cases. Also, a statistically significant lower cycle threshold value was observed with Cobas testing of specimen concentrates tested via the BD SurePath Pap Test (P = .001), suggesting higher sensitivity compared with specimens tested via the ThinPrep Pap Test. Cobas 4800 HPV testing of SP-collected specimen concentrates yields comparable results to TP-collected specimen concentrates. Based on the limited data that we derived, SP collection may be a more favorable methodology than TP collection for HPV testing of individuals at high risk in our ethnically diverse, urban patient population. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Binder effect on seashell structure
NASA Astrophysics Data System (ADS)
Kamarudin, Kamarul Azhar; Hatta, Mohamed Nasrul Mohamed; Baba, Noor Wahida Ab; Hussin, Rosniza; Ismail, Al Emran
2017-10-01
Self-protection or known as defensive covering can be alluded to something that can secure body, building, or vehicles from harm or assault. As the evolution going on, the material utilized as a part of plate armour continue changing, from steel, Kevlar, ceramic and the materials that can give better impact and benefit to the user. A study has been led to distinguish either seashell can be one of the fundamental source to produce protective material due to the properties of seashell that consist of calcium chloride. Seashell is crushed and chipped using variable speed rotor mill and is compressed into specimen shape followed the ASTM C1211-13. Three different samples is tested made from seashells that mix with three different binder i.e. water, kaolin and polyethylene glycol (PEG) each. The specimens then were sintered at elevated controlled temperature 400°C before run for three point bending test to determine their mechanical properties results. Result shows that specimen with water gives highest value for Young's modulus and ultimate strength compared to sample with binder of kaolin and PEG. This proved that seashell powder remain intact even at higher temperature.
Results of Uranium Dioxide-Tungsten Irradiation Test and Post-Test Examination
NASA Technical Reports Server (NTRS)
Collins, J. F.; Debogdan, C. E.; Diianni, D. C.
1973-01-01
A uranium dioxide (UO2) fueled capsule was fabricated and irradiated in the NASA Plum Brook Reactor Facility. The capsule consisted of two bulk UO2 specimens clad with chemically vapor deposited tungsten (CVD W) 0.762 and 0.1016 cm (0.030-and 0.040-in.) thick, respectively. The second specimen with 0.1016-cm (0.040-in.) thick cladding was irradiated at temperature for 2607 hours, corresponding to an average burnup of 1.516 x 10 to the 20th power fissions/cu cm. Postirradiation examination showed distortion in the bottom end cap, failure of the weld joint, and fracture of the central vent tube. Diametral growth was 1.3 percent. No evidence of gross interaction between CVD tungsten or arc-cast tungsten cladding and the UO2 fuel was observed. Some of the fission gases passed from the fuel cavity to the gas surrounding the fuel specimen via the vent tube and possibly the end-cap weld failure. Whether the UO2 loss rates through the vent tube were within acceptable limits could not be determined in view of the end-cap weld failure.
NASA Astrophysics Data System (ADS)
Ning, Jianguo; Wang, Jun; Jiang, Jinquan; Hu, Shanchao; Jiang, Lishuai; Liu, Xuesheng
2018-01-01
A new energy-dissipation method to identify crack initiation and propagation thresholds is introduced. Conventional and cyclic loading-unloading triaxial compression tests and acoustic emission experiments were performed for coal specimens from a 980-m deep mine with different confining pressures of 10, 15, 20, 25, 30, and 35 MPa. Stress-strain relations, acoustic emission patterns, and energy evolution characteristics obtained during the triaxial compression tests were analyzed. The majority of the input energy stored in the coal specimens took the form of elastic strain energy. After the elastic-deformation stage, part of the input energy was consumed by stable crack propagation. However, with an increase in stress levels, unstable crack propagation commenced, and the energy dissipation and coal damage were accelerated. The variation in the pre-peak energy-dissipation ratio was consistent with the coal damage. This new method demonstrates that the crack initiation threshold was proportional to the peak stress ( σ p) for ratios that ranged from 0.4351 to 0.4753 σ p, and the crack damage threshold ranged from 0.8087 to 0.8677 σ p.
NASA Astrophysics Data System (ADS)
Hanafee, Z. M.; Khalina, A.; Norkhairunnisa, M.; Syams, Z. Edi; Liew, K. E.
2017-09-01
This paper investigates the effect of fibre volume fraction on mechanical properties of banana-pineapple leaf (PaLF)-glass reinforced epoxy resin under tensile loading. Uniaxial tensile tests were carried out on specimens with different fibre contents (30%, 40%, 50% in weight). The composite specimens consists of 13 different combinations. The effect of hybridisation between synthetic and natural fibre onto tensile properties was determined and the optimum fibre volume fraction was obtained at 50% for both banana and PaLF composites. Additional 1 layer of woven glass fibre increased the tensile strength of banana-PaLF composite up to 85%.
NASA Technical Reports Server (NTRS)
Hatamleh, Omar; Lyons, Jed; Forman, Royce
2006-01-01
The effects of laser peening, shot peening, and a combination of both on the fatigue life of Friction Stir Welds (FSW) was investigated. The fatigue samples consisted of dog bone specimens and the loading was applied in a direction perpendicular to the weld direction. Several laser peening conditions with different intensities, durations, and peening order were tested to obtain the optimum peening parameters. The surface roughness resulting from various peening techniques was assessed and characterized. The results indicate a significant increase in fatigue life using laser peening compared to shot peened versus their native welded specimens.
Kokolis, John; Chakmakchi, Makdad; Theocharopoulos, Antonios; Prombonas, Anthony
2015-01-01
PURPOSE The mechanical and interfacial characterization of laser welded Co-Cr alloy with two different joint designs. MATERIALS AND METHODS Dumbbell cast specimens (n=30) were divided into 3 groups (R, I, K, n=10). Group R consisted of intact specimens, group I of specimens sectioned with a straight cut, and group K of specimens with a 45° bevel made at the one welding edge. The microstructure and the elemental distributions of alloy and welding regions were examined by an SEM/EDX analysis and then specimens were loaded in tension up to fracture. The tensile strength (TS) and elongation (ε) were determined and statistically compared among groups employing 1-way ANOVA, SNK multiple comparison test (α=.05) and Weibull analysis where Weibull modulus m and characteristic strength σο were identified. Fractured surfaces were imaged by a SEM. RESULTS SEM/EDX analysis showed that cast alloy consists of two phases with differences in mean atomic number contrast, while no mean atomic number was identified for welded regions. EDX analysis revealed an increased Cr and Mo content at the alloy-joint interface. All mechanical properties of group I (TS, ε, m and σο) were found inferior to R while group K showed intermediated values without significant differences to R and I, apart from elongation with group R. The fractured surfaces of all groups showed extensive dendritic pattern although with a finer structure in the case of welded groups. CONCLUSION The K shape joint configuration should be preferred over the I, as it demonstrates improved mechanical strength and survival probability. PMID:25722836
Laser thermal shock and fatigue testing system
NASA Astrophysics Data System (ADS)
Fantini, Vincenzo; Serri, Laura; Bianchi, P.
1997-08-01
Thermal fatigue consists in repeatedly cycling the temperature of a specimen under test without any other constraint and stopping the test when predefined damage aspects. The result is a lifetime in terms of number of cycles. The parameters of the thermal cycle are the following: minimum and maximum temperature, time of heating, of cooling and time at high or at low temperature. When the temperature jump is very big and fast, phenomena of thermal shock can be induced. Among the numerous techniques used to perform these tests, the laser thermal fatigue cycling is very effective when fast heating of small and localized zones is required. That's the case of test performed to compare new and repaired blades of turbogas machines or components of combustion chambers of energy power plants. In order to perform these tests a thermal fatigue system, based on 1 kW Nd-YAG laser as source of heating, has been developed. The diameter of the heated zone of the specimen irradiated by the laser is in the range 0.5 - 20 mm. The temperatures can be chosen between 200 degree(s)C and 1500 degree(s)C and the piece can be maintained at high and/or low temperature from 0 s to 300 s. Temperature are measured by two sensors: a pyrometer for the high range (550 - 1500 degree(s)C) and a contactless thermocouple for the low range (200 - 550 degree(s)C). Two different gases can be blown on the specimen in the irradiated spot or in sample backside to speed up cooling phase. A PC-based control unit with a specially developed software performs PID control of the temperature cycle by fast laser power modulation. A high resolution vision system of suitable magnification is connected to the control unit to detect surface damages on the specimen, allowing real time monitoring of the tested zone as well as recording and reviewing the images of the sample during the test. Preliminary thermal fatigue tests on flat specimens of INCONEL 738 and HAYNES 230 are presented. IN738 samples, laser cladded by powder of the same material to simulate the refurbishing of a damaged turbine blade after long-term operation, are compared to the parents. Lifetimes are decreasing when high temperature of the cycle is increased and shorter lifetimes of repaired pieces have been found. Laser and TIG welding on HY230 specimens are compared to the parent. Parent and repaired samples have no evidence of cracks after 1500 thermal cycles between 650 and 1000 degree(s)C.
Code of Federal Regulations, 2012 CFR
2012-01-01
... ruminant test specimens for diagnostic purposes; and reservation fees for space at quarantine facilities... for ruminants and for ruminant test specimens for diagnostic purposes; and reservation fees for space...) For ruminants and ruminant test specimens for diagnostic screening purposes intended for importation...
Code of Federal Regulations, 2013 CFR
2013-01-01
... ruminant test specimens for diagnostic purposes; and reservation fees for space at quarantine facilities... for ruminants and for ruminant test specimens for diagnostic purposes; and reservation fees for space...) For ruminants and ruminant test specimens for diagnostic screening purposes intended for importation...
Code of Federal Regulations, 2014 CFR
2014-01-01
... ruminant test specimens for diagnostic purposes; and reservation fees for space at quarantine facilities... for ruminants and for ruminant test specimens for diagnostic purposes; and reservation fees for space...) For ruminants and ruminant test specimens for diagnostic screening purposes intended for importation...
Code of Federal Regulations, 2010 CFR
2010-01-01
... ruminant test specimens for diagnostic purposes; and reservation fees for space at quarantine facilities... for ruminants and for ruminant test specimens for diagnostic purposes; and reservation fees for space...) For ruminants and ruminant test specimens for diagnostic screening purposes intended for importation...
Code of Federal Regulations, 2011 CFR
2011-01-01
... ruminant test specimens for diagnostic purposes; and reservation fees for space at quarantine facilities... for ruminants and for ruminant test specimens for diagnostic purposes; and reservation fees for space...) For ruminants and ruminant test specimens for diagnostic screening purposes intended for importation...
Apparatus for automated testing of biological specimens
Layne, Scott P.; Beugelsdijk, Tony J.
1999-01-01
An apparatus for performing automated testing of infections biological specimens is disclosed. The apparatus comprise a process controller for translating user commands into test instrument suite commands, and a test instrument suite comprising a means to treat the specimen to manifest an observable result, and a detector for measuring the observable result to generate specimen test results.
Flexural Behavior of GFRP Tubes Filled with Magnetically Driven Concrete
Xie, Fang; Chen, Ju; Dong, Xinlong; Feng, Bing
2018-01-01
Experimental investigation of GFRP (glass fiber reinforced polymer) tubes that were filled with magnetically driven concrete was carried out to study the flexural behavior of specimens under bending. Specimens having different cross section and lengths were tested. The test specimens were fabricated by filling magnetically driven concrete into the GFRP tubes and the concrete was vibrated using magnetic force. Specimens vibrated using vibrating tube were also tested for comparison. In addition, specimens having steel reinforcing bars and GFRP bars were both tested to study the effect of reinforcing bars on the magnetically driven concrete. The load-displacement curves, load-strain curves, failure mode, and ultimate strengths of test specimens were obtained. Design methods for the flexural stiffness of test specimens were also discussed in this study. PMID:29316732
Flexural Behavior of GFRP Tubes Filled with Magnetically Driven Concrete.
Xie, Fang; Chen, Ju; Dong, Xinlong; Feng, Bing
2018-01-08
Experimental investigation of GFRP (glass fiber reinforced polymer) tubes that were filled with magnetically driven concrete was carried out to study the flexural behavior of specimens under bending. Specimens having different cross section and lengths were tested. The test specimens were fabricated by filling magnetically driven concrete into the GFRP tubes and the concrete was vibrated using magnetic force. Specimens vibrated using vibrating tube were also tested for comparison. In addition, specimens having steel reinforcing bars and GFRP bars were both tested to study the effect of reinforcing bars on the magnetically driven concrete. The load-displacement curves, load-strain curves, failure mode, and ultimate strengths of test specimens were obtained. Design methods for the flexural stiffness of test specimens were also discussed in this study.
Southern, Timothy R.; Racsa, Lori D.; Albariño, César G.; Fey, Paul D.; Hinrichs, Steven H.; Murphy, Caitlin N.; Herrera, Vicki L.; Sambol, Anthony R.; Hill, Charles E.; Ryan, Emily L.; Kraft, Colleen S.; Campbell, Shelley; Sealy, Tara K.; Schuh, Amy; Ritchie, James C.; Lyon, G. Marshall; Mehta, Aneesh K.; Varkey, Jay B.; Ribner, Bruce S.; Brantly, Kent P.; Ströher, Ute; Iwen, Peter C.
2015-01-01
Rapid, reliable, and easy-to-use diagnostic assays for detection of Zaire ebolavirus (ZEBOV) are urgently needed. The goal of this study was to examine the agreement among emergency use authorization (EUA) tests for the detection of ZEBOV nucleic acids, including the BioFire FilmArray BioThreat (BT) panel, the FilmArray BT-E panel, and the NP2 and VP40 quantitative real-time reverse transcriptase (qRT) PCR assays from the Centers for Disease Control and Prevention (CDC). Specimens used in this study included whole blood spiked with inactivated ZEBOV at known titers and whole-blood, plasma, and urine clinical specimens collected from persons diagnosed with Ebola virus disease (EVD). The agreement for FilmArray and qRT-PCR results using contrived whole-blood specimens was 100% (6/6 specimens) for each ZEBOV dilution from 4 × 107 to 4 × 102 50% tissue culture infective dose (TCID50)/ml, as well as the no-virus negative-control sample. The limit of detection for FilmArray and qRT-PCR assays with inactivated ZEBOV, based on duplicate positive results, was determined to be 4 × 102 TCID50/ml. Rates of agreement between FilmArray and qRT-PCR results for clinical specimens from patients with EVD were 85% (23/27 specimens) for whole-blood specimens, 90% (18/20 specimens) for whole-blood specimens tested by FilmArray testing and matched plasma specimens tested by qRT-PCR testing, and 85% (11/13 specimens) for urine specimens. Among 60 specimens, eight discordant results were noted, with ZEBOV nucleic acids being detected only by FilmArray testing in four specimens and only by qRT-PCR testing in the remaining four specimens. These findings demonstrate that the rapid and easy-to-use FilmArray panels are effective tests for evaluating patients with EVD. PMID:26157148
Ceramic Matrix Composite Vane Subelement Burst Testing
NASA Technical Reports Server (NTRS)
Brewer, David N.; Verrilli, Michael; Calomino, Anthony
2006-01-01
Burst tests were performed on Ceramic Matrix Composite (CMC) vane specimens, manufactured by two vendors, under the Ultra Efficient Engine Technology (UEET) project. Burst specimens were machined from the ends of 76mm long vane sub-elements blanks and from High Pressure Burner Rig (HPBR) tested specimens. The results of burst tests will be used to compare virgin specimens with specimens that have had an Environmental Barrier Coating (EBC) applied, both HPBR tested and untested, as well as a comparison between vendors.
Tensile-Creep Test Specimen Preparation Practices of Surface Support Liners
NASA Astrophysics Data System (ADS)
Guner, Dogukan; Ozturk, Hasan
2017-12-01
Ground support has always been considered as a challenging issue in all underground operations. Many forms of support systems and supporting techniques are available in the mining/tunnelling industry. In the last two decades, a new polymer based material, Thin Spray-on Liner (TSL), has attained a place in the market as an alternative to the current areal ground support systems. Although TSL provides numerous merits and has different application purposes, the knowledge on mechanical properties and performance of this material is still limited. In laboratory studies, since tensile rupture is the most commonly observed failure mechanism in field applications, researchers have generally studied the tensile testing of TSLs with modification of American Society for Testing and Materials (ASTM) D-638 standards. For tensile creep testing, specimen preparation process also follows the ASTM standards. Two different specimen dimension types (Type I, Type IV) are widely preferred in TSL tensile testing that conform to the related standards. Moreover, molding and die cutting are commonly used specimen preparation techniques. In literature, there is a great variability of test results due to the difference in specimen preparation techniques and practices. In this study, a ductile TSL product was tested in order to investigate the effect of both specimen preparation techniques and specimen dimensions under 7-day curing time. As a result, ultimate tensile strength, tensile yield strength, tensile modulus, and elongation at break values were obtained for 4 different test series. It is concluded that Type IV specimens have higher strength values compared to Type I specimens and moulded specimens have lower results than that of prepared by using die cutter. Moreover, specimens prepared by molding techniques have scattered test results. Type IV specimens prepared by die cutter technique are suggested for preparation of tensile test and Type I specimens prepared by die cutter technique should be preferred for tensile creep tests.
Signal processing methods for in-situ creep specimen monitoring
NASA Astrophysics Data System (ADS)
Guers, Manton J.; Tittmann, Bernhard R.
2018-04-01
Previous work investigated using guided waves for monitoring creep deformation during accelerated life testing. The basic objective was to relate observed changes in the time-of-flight to changes in the environmental temperature and specimen gage length. The work presented in this paper investigated several signal processing strategies for possible application in the in-situ monitoring system. Signal processing methods for both group velocity (wave-packet envelope) and phase velocity (peak tracking) time-of-flight were considered. Although the Analytic Envelope found via the Hilbert transform is commonly applied for group velocity measurements, erratic behavior in the indicated time-of-flight was observed when this technique was applied to the in-situ data. The peak tracking strategies tested had generally linear trends, and tracking local minima in the raw waveform ultimately showed the most consistent results.
Investigation of Asphalt Mixture Creep Behavior Using Thin Beam Specimens
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zofka, Adam; Marasteanu, Mihai; Turos, Mugur
2008-02-15
The asphalt pavement layer consists of two or more lifts of compacted asphalt mixture; the top of the layer is also exposed to aging, a factor that significantly affects the mixture properties. The current testing specifications use rather thick specimens that cannot be used to investigate the gradual change in properties with pavement depth. This paper investigates the feasibility of using the 3-point bending test with thin asphalt mixture beams (127x12.7x6.35 mm) to determine the low-temperature creep compliance of the mixtures. Several theoretical and semi-empirical models, from the theory of composites, are reviewed and evaluated using numerical and experimental data.more » Preliminary results show that this method can be used for low-temperature mixture characterization but several crucial factors need further inspection and interpretation.« less
Constitutive and life modeling of single crystal blade alloys for root attachment analysis
NASA Technical Reports Server (NTRS)
Meyer, T. G.; Mccarthy, G. J.; Favrow, L. H.; Anton, D. L.; Bak, Joe
1988-01-01
Work to develop fatigue life prediction and constitutive models for uncoated attachment regions of single crystal gas turbine blades is described. At temperatures relevant to attachment regions, deformation is dominated by slip on crystallographic planes. However, fatigue crack initiation and early crack growth are not always observed to be crystallographic. The influence of natural occurring microporosity will be investigated by testing both hot isostatically pressed and conventionally cast PWA 1480 single crystal specimens. Several differnt specimen configurations and orientations relative to the natural crystal axes are being tested to investigate the influence of notch acuity and the material's anisotropy. Global and slip system stresses in the notched regions were determined from three dimensional stress analyses and will be used to develop fatigue life prediction models consistent with the observed lives and crack characteristics.
Creep Rupture of the Simulated HAZ of T92 Steel Compared to that of a T91 Steel
Peng, Yu-Quan; Chen, Tai-Cheng; Chung, Tien-Jung; Jeng, Sheng-Long; Huang, Rong-Tan; Tsay, Leu-Wen
2017-01-01
The increased thermal efficiency of fossil power plants calls for the development of advanced creep-resistant alloy steels like T92. In this study, microstructures found in the heat-affected zone (HAZ) of a T92 steel weld were simulated to evaluate their creep-rupture-life at elevated temperatures. An infrared heating system was used to heat the samples to 860 °C (around AC1), 900 °C (slightly below AC3), and 940 °C (moderately above AC3) for one minute, before cooling to room temperature. The simulated specimens were then subjected to a conventional post-weld heat treatment (PWHT) at 750 °C for two hours, where both the 900 °C and 940 °C simulated specimens had fine grain sizes. In the as-treated condition, the 900 °C simulated specimen consisted of fine lath martensite, ferrite subgrains, and undissolved carbides, while residual carbides and fresh martensite were found in the 940 °C simulated specimen. The results of short-term creep tests indicated that the creep resistance of the 900 °C and 940 °C simulated specimens was poorer than that of the 860 °C simulated specimens and the base metal. Moreover, simulated T92 steel samples had higher creep strength than the T91 counterpart specimens. PMID:28772500
Creep Rupture of the Simulated HAZ of T92 Steel Compared to that of a T91 Steel.
Peng, Yu-Quan; Chen, Tai-Cheng; Chung, Tien-Jung; Jeng, Sheng-Long; Huang, Rong-Tan; Tsay, Leu-Wen
2017-02-08
The increased thermal efficiency of fossil power plants calls for the development of advanced creep-resistant alloy steels like T92. In this study, microstructures found in the heat-affected zone (HAZ) of a T92 steel weld were simulated to evaluate their creep-rupture-life at elevated temperatures. An infrared heating system was used to heat the samples to 860 °C (around A C1 ), 900 °C (slightly below A C3 ), and 940 °C (moderately above A C3 ) for one minute, before cooling to room temperature. The simulated specimens were then subjected to a conventional post-weld heat treatment (PWHT) at 750 °C for two hours, where both the 900 °C and 940 °C simulated specimens had fine grain sizes. In the as-treated condition, the 900 °C simulated specimen consisted of fine lath martensite, ferrite subgrains, and undissolved carbides, while residual carbides and fresh martensite were found in the 940 °C simulated specimen. The results of short-term creep tests indicated that the creep resistance of the 900 °C and 940 °C simulated specimens was poorer than that of the 860 °C simulated specimens and the base metal. Moreover, simulated T92 steel samples had higher creep strength than the T91 counterpart specimens.
External quality assurance in nongynecologic cytology: The Australasian experience.
Shield, Paul W; Frost, Felicity; Finnimore, Jo L; Wright, R Gordon; Cummings, Margaret C
2017-05-01
The Royal College of Pathologists of Australasia Cytopathology Quality Assurance Program has operated an external quality assurance program in nongynecologic cytopathology since 1993. Glass slide preparations of a wide range of nongynecologic cases were circulated to approximately 200 cytopathology laboratories in 16 countries. General nongynecologic cytology cases were manufactured from residual specimens after routine diagnosis. Fine-needle aspiration (FNA) cases were made by sampling fresh tissue and making direct specimens. The majority of cases consisted of both air-dried and fixed preparations. Results returned to laboratories included illustrated case discussions highlighting diagnostic features, key differential diagnoses, and useful adjunctive tests. The current study reviewed >22,000 results for 123 nongynecologic cases. Cases found to cause the most diagnostic difficulties included serous effusion cases with metastatic carcinoma in a dispersed pattern, well-differentiated carcinoma, and cellular reactive cases; urine specimens with sparse malignant cells; reactive pneumocytes in a bronchoalveolar lavage; breast FNA cases with papillary lesions; gestational specimens; and fibroadenoma. FNA specimens from the lung and thyroid, particularly papillary thyroid carcinoma, generally were well reported. The use of multiple preparations of the same specimen has allowed interlaboratory comparison, and the quality assurance program has played an educational role as well as informing the laboratory accreditation process. Cancer Cytopathol 2017;125:349-361. © 2017 American Cancer Society. © 2017 American Cancer Society.
Tibesku, C O; Innocenti, B; Wong, P; Salehi, A; Labey, L
2012-02-01
Long-term success of contemporary total knee replacements relies to a large extent on proper implant alignment. This study was undertaken to test whether specimen-matched cutting blocks based on computed axial tomography (CT) scans could provide accurate rotational alignment of the femoral component. CT scans of five fresh frozen full leg cadaver specimens, equipped with infrared reflective markers, were used to produce a specimen-matched femoral cutting block. Using those blocks, the bone cuts were made to implant a bi-compartmental femoral component. Rotational alignment of the components in the horizontal plane was determined using an optical measurement system and compared with all relevant rotational reference axes identified on the CT scans. Average rotational alignment for the bi-compartmental component in the horizontal plane was 1.9° (range 0°-6.3°; standard deviation 2.6°). One specimen that showed the highest deviation from the planned alignment also featured a completely degraded medial articular surface. The CT-based specimen-matched cutting blocks achieved good rotational alignment accuracy except for one specimen with badly damaged cartilage. In such cases, imaging techniques that visualize the cartilage layer might be more suitable to design cutting blocks, as they will provide a better fit and increased surface support.
Drew, Bryn; Jones, Edward C.; Reinsberg, Stefan; Yung, Andrew C.; Goldenberg, S. Larry; Kozlowski, Piotr
2012-01-01
Purpose To develop a device for sectioning prostatectomy specimens that would facilitate comparison between histology and in vivo MRI. Materials and methods A multi-bladed cutting device was developed, which consists of an adjustable box capable of accommodating a prostatectomy specimen up to 85 mm in size in the lateral direction, a “plunger” tool to press on the excised gland from the top to prevent it from rolling or sliding during sectioning, and a multi-bladed knife assembly capable of holding up to 21 blades at 4 mm intervals. The device was tested on a formalin fixed piece of meat and subsequently used to section a prostatectomy specimen. Histology sections were compared with T2-weighted MR images acquired in vivo prior to the prostatectomy procedure. Results The prostatectomy specimen slices were very uniform in thickness with each face parallel to the other with no visible sawing marks on the sections by the blades after the cut. MRI and histology comparison showed good correspondence between the two images. Conclusion The developed device allows sectioning of prostatectomy specimens into parallel cuts at a specific orientation and fixed intervals. Such a device is useful in facilitating accurate correlation between histology and MRI data. PMID:20882632
A regional analysis of epidermal growth factor receptor (EGFR) mutated lung cancer for HSE South.
Kelly, D; Mc Sorley, L; O'Shea, E; Mc Carthy, E; Bowe, S; Brady, C; Sui, J; Dawod, M A; O'Brien, O; Graham, D; McCarthy, J; Burke, L; Power, D; O'Reilly, S; Bambury, R M; Mahony, D O
2017-11-01
EGFR mutated lung cancer represents a subgroup with distinct clinical presentations, prognosis, and management requirements. We investigated the survival, prognostic factors, and real-world treatment of NSCLC patients with EGFR mutation in clinical practice. A retrospective review of all specimens sent for EGFR analysis from December 2009 to September 2015 was performed. Patient demographics, specimen type, EGFR mutation status/type, stage at diagnosis, treatment, response rate, and survival data were recorded. 27/334 (8%) patient specimens sent for EGFR testing tested positive for a sensitising EGFR mutation. The median age was 65 years (40-85 years). Exon 19 deletion represented the most commonly detected alteration, accounting for 39% (n = 11). First-line treatment for those with Exon 18, 19, or 21 alterations (n = 24) was with an EGFR tyrosine kinase inhibitor (TKI) in 79% (n = 19). Objective response rate among these patients was 74% and median duration of response was 13 months (range 7-35 months). The incidence of EGFR mutation in our cohort of NSCLC is 9% which is consistent with mutation incidence reported in other countries. The rate of EGFR mutation in our population is slightly below that reported internationally, but treatment outcomes are consistent with published data. Real-world patient data have important contributions to make with regard to quality measurement, incorporating patient experience into guidelines and identifying safety signals.
The production of calibration specimens for impact testing of subsize Charpy specimens
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alexander, D.J.; Corwin, W.R.; Owings, T.D.
1994-09-01
Calibration specimens have been manufactured for checking the performance of a pendulum impact testing machine that has been configured for testing subsize specimens, both half-size (5.0 {times} 5.0 {times} 25.4 mm) and third-size (3.33 {times} 3.33 {times} 25.4 mm). Specimens were fabricated from quenched-and-tempered 4340 steel heat treated to produce different microstructures that would result in either high or low absorbed energy levels on testing. A large group of both half- and third-size specimens were tested at {minus}40{degrees}C. The results of the tests were analyzed for average value and standard deviation, and these values were used to establish calibration limitsmore » for the Charpy impact machine when testing subsize specimens. These average values plus or minus two standard deviations were set as the acceptable limits for the average of five tests for calibration of the impact testing machine.« less
10 CFR 26.89 - Preparing to collect specimens for testing.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Preparing to collect specimens for testing. 26.89 Section 26.89 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.89 Preparing to collect specimens for testing. (a) When an individual has been notified of a...
10 CFR 26.89 - Preparing to collect specimens for testing.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Preparing to collect specimens for testing. 26.89 Section 26.89 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.89 Preparing to collect specimens for testing. (a) When an individual has been notified of a...
10 CFR 26.89 - Preparing to collect specimens for testing.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Preparing to collect specimens for testing. 26.89 Section 26.89 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.89 Preparing to collect specimens for testing. (a) When an individual has been notified of a...
10 CFR 26.89 - Preparing to collect specimens for testing.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Preparing to collect specimens for testing. 26.89 Section 26.89 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.89 Preparing to collect specimens for testing. (a) When an individual has been notified of a...
10 CFR 26.89 - Preparing to collect specimens for testing.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Preparing to collect specimens for testing. 26.89 Section 26.89 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.89 Preparing to collect specimens for testing. (a) When an individual has been notified of a...
Apparatus for Hot Impact Testing of Material Specimens
NASA Technical Reports Server (NTRS)
Pawlik, Ralph J.; Choi, Sung R.
2006-01-01
An apparatus for positioning and holding material specimens is a major subsystem of a system for impact testing of the specimens at temperatures up to 1,500 C. This apparatus and the rest of the system are designed especially for hot impact testing of advanced ceramics, composites, and coating materials. The apparatus includes a retaining fixture on a rotating stage on a vertically movable cross support driven by a linear actuator. These components are located below a furnace wherein the hot impact tests are performed (see Figure 1). In preparation for a test, a specimen is mounted on the retaining fixture, then the cross support is moved upward to raise the specimen, through an opening in the bottom of the furnace, to the test position inside the furnace. On one side of the furnace there is another, relatively small opening on a direct line to the specimen. Once the specimen has become heated to the test temperature, the test is performed by using an instrumented external pressurized-gas-driven gun to shoot a projectile through the side opening at the specimen.
Urine specimen validity test for drug abuse testing in workplace and court settings.
Lin, Shin-Yu; Lee, Hei-Hwa; Lee, Jong-Feng; Chen, Bai-Hsiun
2018-01-01
In recent decades, urine drug testing in the workplace has become common in many countries in the world. There have been several studies concerning the use of the urine specimen validity test (SVT) for drug abuse testing administered in the workplace. However, very little data exists concerning the urine SVT on drug abuse tests from court specimens, including dilute, substituted, adulterated, and invalid tests. We investigated 21,696 submitted urine drug test samples for SVT from workplace and court settings in southern Taiwan over 5 years. All immunoassay screen-positive urine specimen drug tests were confirmed by gas chromatography/mass spectrometry. We found that the mean 5-year prevalence of tampering (dilute, substituted, or invalid tests) in urine specimens from the workplace and court settings were 1.09% and 3.81%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the workplace were 89.2%, 6.8%, and 4.1%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the court were 94.8%, 1.4%, and 3.8%, respectively. No adulterated cases were found among the workplace or court samples. The most common drug identified from the workplace specimens was amphetamine, followed by opiates. The most common drug identified from the court specimens was ketamine, followed by amphetamine. We suggest that all urine specimens taken for drug testing from both the workplace and court settings need to be tested for validity. Copyright © 2017. Published by Elsevier B.V.
NASA Technical Reports Server (NTRS)
Ratcliffe, James G.
2004-01-01
The edge crack torsion (ECT) test is designed to initiate mode III delamination growth in composite laminates. An ECT specimen is a rectangular laminate, containing an edge delamination at the laminate mid-plane. Torsion load is applied to the specimens, resulting in relative transverse shear sliding of the delaminated faces. The test data reduction schemes are intended to yield initiation values of critical mode III strain energy release rate, G(sub IIIc), that are constant with delamination length. The test has undergone several design changes during its development. The objective of this paper was to determine the suitability of the current ECT test design as a mode III fracture test. To this end, ECT tests were conducted on specimens manufactured from IM7/8552 and specimens made from S2/8552 tape laminates. Several specimens, each with different delamination lengths are tested. Detailed, three-dimensional finite element analyses of the specimens were performed. The analysis results were used to calculate the distribution of mode I, mode II, and mode III strain energy release rate along the delamination front. The results indicated that mode III-dominated delamination growth would be initiated from the specimen center. However, in specimens of both material types, the measured values of G(sub IIIc) exhibited significant dependence on delamination length. Furthermore, there was a large amount of scatter in the data. Load-displacement response of the specimens exhibited significant deviation from linearity before specimen failure. X-radiographs of a sample of specimens revealed that damage was initiated in the specimens prior to failure. Further inspection of the failure surfaces is required to identify the damage and determine that mode III delamination is initiated in the specimens.
Axial-Load Fatigue Tests on 17-7 PH Stainless Steel Under Constant-Amplitude Loading
NASA Technical Reports Server (NTRS)
Leybold, Herbert A.
1960-01-01
Axial-load fatigue tests were conducted at room temperature on notched and unnotched sheet specimens of 17-7 PH stainless steel in Condition TH 1050. The notched specimens had theoretical stress-concentration factors of 2.32, 4.00, and 5.00. All specimens were tested under completely reversed loading. S-N curves are presented for each specimen configuration and ratios of fatigue strengths of unnotched specimens to those of notched specimens are given. Predictions of the fatigue behavior of notched specimens near the fatigue limit were made.
Taylor, Zeike A; Kirk, Thomas B; Miller, Karol
2007-10-01
The theoretical framework developed in a companion paper (Part I) is used to derive estimates of mechanical response of two meniscal cartilage specimens. The previously developed framework consisted of a constitutive model capable of incorporating confocal image-derived tissue microstructural data. In the present paper (Part II) fibre and matrix constitutive parameters are first estimated from mechanical testing of a batch of specimens similar to, but independent from those under consideration. Image analysis techniques which allow estimation of tissue microstructural parameters form confocal images are presented. The constitutive model and image-derived structural parameters are then used to predict the reaction force history of the two meniscal specimens subjected to partially confined compression. The predictions are made on the basis of the specimens' individual structural condition as assessed by confocal microscopy and involve no tuning of material parameters. Although the model does not reproduce all features of the experimental curves, as an unfitted estimate of mechanical response the prediction is quite accurate. In light of the obtained results it is judged that more general non-invasive estimation of tissue mechanical properties is possible using the developed framework.
Roberts, Angela; Austin, William; Evans, Katharine; Bird, Clare; Schweizer, Magali; Darling, Kate
2016-01-01
A robust and consistent taxonomy underpins the use of fossil material in palaeoenvironmental research and long-term assessment of biodiversity. This study presents a new integrated taxonomic protocol for benthic foraminifera by unequivocally reconciling the traditional taxonomic name to a specific genetic type. To implement this protocol, a fragment of the small subunit ribosomal RNA (SSU rRNA) gene is used in combination with 16 quantitative morphometric variables to fully characterise the benthic foraminiferal species concept of Elphidium williamsoni Haynes, 1973. A combination of live contemporary topotypic specimens, original type specimens and specimens of genetic outliers were utilised in this study. Through a series of multivariate statistical tests we illustrate that genetically characterised topotype specimens are morphologically congruent with both the holotype and paratype specimens of E. williamsoni Haynes, 1973. We present the first clear link between morphologically characterised type material and the unique SSU rRNA genetic type of E. williamsoni. This example provides a standard framework for the benthic foraminifera which bridges the current discontinuity between molecular and morphological lines of evidence, allowing integration with the traditional Linnaean roots of nomenclature to offer a new prospect for taxonomic stability. PMID:27388271
In vitro results with special plastics for biodegradable endoureteral stents.
Schlick, R W; Planz, K
1998-10-01
Internal ureteral stents are widely used in urologic practice for temporary urinary diversion, but all double-J catheters to date exhibit the same disadvantage; that is, they have to be removed endoscopically, necessitating further intervention. We tested different materials (designated G100X-15xLB and G100X-20xLB) to develop a biodegradable (biodissolvable) endoureteral stent that can be held in place without functional loss yet could be dissolved by changing the environment. The principle of the biochemical background is based on the physiological milieu of the urine. The plastics tested are stable in acidic and dissolve in alkaline conditions. In a first step, specimens of two polymers were placed in artificial urine of different pH over a period of 60 days and monitored for integrity (solution trial). In a second step, artificial urine was set in motion (744 mL/24 hours) an infusion pump (Volumed microVP 5000; Fresenius AG, Bad Homburg vdH, Germany) through an infusion set in which a 30-cm piece of the materials to test had been placed (ureter model). Below the inserted specimen, the lumen of the infusion tube was minimized to make obstruction by fragments more possible. In the solution trial, all specimens remained stable under physiologic conditions (pH 5.2) over a period of at least 30 days. The specimens dissolved completely when the pH was adjusted to an alkaline one (pH 7.9). In the ureter model, with pH values of 7.9, all specimens were decomposed after 20 hours, and no occlusion of the model occurred. Using acidic artificial urine, the specimens remained stable with a smooth consistent surface. The dissolution was not a standard chemical one; the materials broke into microscopically small pieces, with fragments of G100X-20xLB being smaller than those of G100X-15xLB. Our first in vitro results show that the tested materials are suitable for further development of biodissolvable endoureteral stents, dissolution of which can be steered by changing the urinary pH.
NASA Technical Reports Server (NTRS)
Choi, Sung R.; Powers, Lynn M.; Nemeth, Noel N.
2000-01-01
Extensive constant stress-rate testing for 96 wt % alumina was conducted in room-temperature distilled water using four different specimen/loading configurations: rectangular beam test specimens under four-point uniaxial flexure, square plate test specimens in ring-on-ring biaxial flexure, square plate test specimens in ball-on-ring biaxial flexure, and dog-boned tensile test specimens in pure tension. The slow crack growth (SCG) parameter n was almost independent of specimen/loading configurations, in either four-point uniaxial flexure, ring-on-ring biaxial flexure, ball-on-ring biaxial flexure, or pure tension, ranging from n = 35 to 47 with an average value of n = 41.1 +/- 4.5. The prediction of fatigue strength/reliability based on the four-point uniaxial flexure data by using the CARES/Life design code as well as a simple PIA model was in good agreement with both the ring-on-ring biaxial and the ball-on-ring biaxial flexure data. A poor prediction using the PIA model was observed for the dog-boned tensile test specimens, presumably due to different flaw population involved in the tensile test specimens.
49 CFR 40.171 - How does an employee request a test of a split specimen?
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 1 2013-10-01 2013-10-01 false How does an employee request a test of a split specimen? 40.171 Section 40.171 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Split Specimen Tests § 40.171 How does an employee request a test of a split specimen? (a...
Interaction of LED light with coinitiator-containing composite resins: effect of dual peaks.
Sim, Jae-Seong; Seol, Hyo-Joung; Park, Jeong-Kil; Garcia-Godoy, Franklin; Kim, Hyung-Il; Kwon, Yong Hoon
2012-10-01
Recently the colour stability of composite resins has been an issue due to the emphasis on the aesthetics of restored teeth. The purpose of the present study was to investigate how dual-peak LED units affect the polymerization of coinitiator-containing composite resins. Five composite resins [coinitiator-containing: Aelite LS Posterior (AL), Tetric EvoCeram (TE), and Vit-l-escence (VI); only CQ-containing: Grandio (GD) and Filtek Z350 (Z3)] were light cured using four different light-curing units (LCUs). Among them, Bluephase G2 (BP) and G-light (GL) were dual-peak LED LCUs. Microhardness, polymerization shrinkage, flexural, and compressive properties were measured. BP and GL had no consistent effect on the microhardness of AL, TE, and VI on the top and bottom surfaces of resin specimens. Among the specimens, AL and VI showed the least (9.86-10.41 μm) and greatest (17.58-19.21 μm) polymerization shrinkage, respectively. However, the effect of BP and GL on the shrinkage of specimens was not consistent. Among the specimens, GD showed the greatest flexural properties [strength (FS) and modulus (FM)] and TE showed the lowest flexural and compressive properties [strength (CS) and modulus (CM)]. In same resin product, maximum FS and CS differences due to the different LCUs were 10.3-21.0% and 3.6-9.2%, respectively. Furthermore, the influences of BP and GL on FS and CS were not consistent. The tested dual-peak LED LCUs had no consistent synergic effect on the polymerization of coinitiator-containing composite resins as compared with QTH and single-peak LED LCUs. The dual-peak LED LCUs achieve a similar degree of polymerization in coinitiator-composite resins as QTH and single-peak LED LCUs did. Choice of LCU does not appear to be a determinant of the light curing of coinitiator-composite resins. Copyright © 2012 Elsevier Ltd. All rights reserved.
10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...
10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...
10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...
10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...
10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...
Effects of long duration exposure to simulated space environment on nonmetallic materials properties
NASA Technical Reports Server (NTRS)
Peacock, C. L., Jr.; Whitaker, A. F.
1983-01-01
Nonmetallic materials specimens from the Viking program were tested in situ invacuo after continuous thermal vacuum exposure from 1971/1972 to the present. Eleven tests were done on appropriate specimens of 30 materials; however, no single material received all the tests. Some specimens also were exposed to 1 or 2.5 MeV electrons at differing fluences before testing. Baseline exposure data is reported for graphite/epoxy specimens that were exposed to vacuum since 1974. These materials were transferred to the thermal vacuum storage facility for future in situ testing and irradiation. Thin G/E specimens were tensile tested after thermal-vacuum cycling exposure. Photomicrographic examinations and SEM analyses were done on the failed specimens.
Sensitization to fragrance materials in Indonesian cosmetics.
Roesyanto-Mahadi, I D; Geursen-Reitsma, A M; van Joost, T; van den Akker, T W
1990-04-01
2 different groups of patients were patch tested with 2 test series (A and B) containing extracts of fragrance raw materials, traditionally used in Indonesian cosmetics. Series A consisted of diluted extracts of commercially available Indonesian fragrances. Series B consisted of extracts prepared in our department from corresponding indigenous flowers and fruits. Group 1 consisted of 32 patients positive to fragrance-mix, of whom 8 (25%) had positive tests to 1 or more of the different extracts of fragrance raw materials. Reactions were observed to extracts of: Rosa hybrida Hort (7); Canangium odoratum Baill (5); Citrus aurantifolia Swingle (4); Jasminum sambac Ait (2). 6 of the 8 patients had reactions to 1 or more of the components of fragrance-mix: oakmoss (3); cinnamic alcohol (2), isoeugenol (1); cinnamic aldehyde (1) and geraniol (1). Group 2 consisted of 159 patients patch tested on suspicion of contact dermatitis, who were fragrance-mix negative. Only 2 (1.2%) had a positive patch test to the extracts of fragrance raw materials. Specimens taken (as is) from the flowers and citrus fruits (being the basis sources of the fragrance raw materials) were less antigenic. The use of additional test series in Indonesia to detect allergy to traditional cosmetics and perfumes merits further investigation.
Batman-cracks. Observations and numerical simulations
NASA Astrophysics Data System (ADS)
Selvadurai, A. P. S.; Busschen, A. Ten; Ernst, L. J.
1991-05-01
To ensure mechanical strength of fiber reinforced plastics (FRP), good adhesion between fibers and the matrix is considered to be an essential requirement. An efficient test of fiber-matrix interface characterization is the fragmentation test which provides information about the interface slip mechanism. This test consists of the longitudinal loading of a single fiber which is embedded in a matrix specimen. At critical loads the fiber experiences fragmentation. This fragmentation will terminate depending upon the shear-slip strength of the fiber-matrix adhesion, which is inversely proportional to average fragment lengths. Depending upon interface strength characteristics either bond or slip matrix fracture can occur at the onset of fiber fracture. Certain particular features of matrix fracture are observed at the locations of fiber fracture in situations where there is sufficient interface bond strength. These refer to the development of fractures with a complex surface topography. The experimental procedure involved in the fragmentation tests is discussed and the boundary element technique to examine the development of multiple matrix fractures at the fiber fracture locations is examined. The mechanics of matrix fracture is examined. When bond integrity is maintained, a fiber fracture results in a matrix fracture. The matrix fracture topography in a fragmentation test is complex; however, simplified conoidal fracture patterns can be used to investigate the crack extension phenomena. Via a mixed-mode fracture criterion, the generation of a conoidal fracture pattern in the matrix is investigated. The numerical results compare favorably with observed experimental data derived from tests conducted on fragmentation test specimens consisting of a single glass fiber which is embedded in a polyester matrix.
Vortex Structures in the Shock-deformed Armor Steels
NASA Astrophysics Data System (ADS)
Atroshenko, Svetlana; Meshcheryakov, Yuri; Natalia, Naumova
2009-06-01
Several kinds of armor steel were tested under uniaxial strain conditions within impact velocity range from 250 to 400 m/s. Using optical and REM microscopy, the post shocked specimens were studied to reveal the kinematical mechanisms of dynamic deformation at the mesoscale. In all the specimens, the cross-section of specimens was found to be filled with rotational cells of very complex space morphology. Each rotation cell consists of central core of 1-2 μm in diameter and family of petals surrounding the core, so the space configuration of eddy is closely remands a fan of total size 6-7 μm. During the deformation, the petals move around the core providing the vortical motion of rotation as a whole. Dependence of rotational cell density on the strain rate changes non-monotonously, maximum density corresponds to maximum macrohardness and maximum of spall-strength of steel.
Wilson, D A; Keegan, K G; Carson, W L
1999-01-01
This study compared the mechanical properties of the normal intact suspensory apparatus and two methods of fixation for repair of transverse, midbody fractures of the proximal sesamoid bones of adult horses: transfixation wiring (TW) and screws placed in lag fashion (LS). An in vitro, paired study using equine cadaver limbs mounted in a loading apparatus was used to test the mechanical properties of TW and LS. Seventeen paired (13 repaired, 4 normal) equine cadaver limbs consisting of the suspensory apparatus third metacarpal bone, and first and second phalanges. The two methods of repair and normal intact specimens were evaluated in single cycle-to-failure loading. Yield failure was defined to occur at the first notable discontinuity (>50 N) in the load-displacement curve, the first visible failure as evident on the videotape, or a change in the slope of the moment-fetlock angle curve. Ultimate failure was defined to occur at the highest load resisted by the specimen. Corresponding resultant force and force per kg of body weight on the suspensory apparatus, fetlock joint moment, and angle of fetlock dorsiflexion were calculated by use of specimen dimensions and applied load. These were compared along with specimen stiffness, and ram displacement. Load on the suspensory apparatus, load on the suspensory apparatus per kg of body weight, moment, applied load, and angle of fetlock dorsiflexion at yield failure were significantly greater for the TW-repaired than for the LS-repaired specimens. A 3 to 5 mm gap was observed before yield failure in most TW-repaired osteotomies. Transfixation wiring provided greater strength to yield failure than screws placed in lag fashion in single cycle load-to-failure mechanical testing of repaired transverse osteotomized specimens of the medial proximal forelimb sesamoid bone.
Balogh, Daniel G; Biskup, Jeffery J; O'Sullivan, M Gerard; Scott, Ruth M; Groschen, Donna; Evans, Richard B; Conzemius, Michael G
2016-04-01
To evaluate the biochemical and biomechanical properties of native and decellularized superficial digital flexor tendons (SDFTs) and deep digital flexor tendons (DDFTs) harvested from the pelvic limbs of orthopedically normal dogs. 22 commercially supplied tendon specimens (10 SDFT and 12 DDFT) harvested from the pelvic limbs of 13 canine cadavers. DNA, glycosaminoglycan, collagen, and protein content were measured to biochemically compare native and decellularized SDFT and DDFT specimens. Mechanical testing was performed on 4 groups consisting of native tendons (5 SDFTs and 6 DDFTs) and decellularized tendons (5 SDFTs and 6 DDFTs). All tendons were preconditioned, and tension was applied to failure at 0.5 mm/s. Failure mode was video recorded for each tendon. Load-deformation and stress-strain curves were generated; calculations were performed to determine the Young modulus and stiffness. Biochemical and biomechanical data were statistically compared by use of the Wilcoxon rank sum test. Decellularized SDFT and DDFT specimens had significantly less DNA content than did native tendons. No significant differences were identified between native and decellularized specimens with respect to glycosaminoglycan, collagen, or protein content. Biomechanical comparison yielded no significant intra- or intergroup differences. All DDFT constructs failed at the tendon-clamp interface, whereas nearly half (4/10) of the SDFT constructs failed at midsubstance. Decellularized commercial canine SDFT and DDFT specimens had similar biomechanical properties, compared with each other and with native tendons. The decellularization process significantly decreased DNA content while minimizing loss of extracellular matrix components. Decellularized canine flexor tendons may provide suitable, biocompatible graft scaffolds for bioengineering applications such as tendon or ligament repair.
Jeong, Y.; Iadicola, M.A.; Gnäupel-Herold, T.; Creuziger, A.
2017-01-01
Constitutive behaviors of an interstitial-free steel sample were measured using an augmented Marciniak experiment. In these tests, multiaxial strain field data of the flat specimens were measured by the digital image correlation technique. In addition, the flow stress was measured using an X-ray diffractometer. The flat specimens in three different geometries were tested in order to achieve 1) balanced biaxial strain, and plane strain tests with zero strain in either 2) rolling direction or 3) transverse direction. The multiaxial stress and strain data were processed to obtain plastic work contours with reference to a uniaxial tension test along the rolling direction. The experimental results show that the mechanical behavior of the subjected specimen deviates significantly from isotropic behavior predicted by the von Mises yield criterion. The initial yield loci measured by a Marciniak tester is in good agreement with what is predicted by Hill's yield criterion. However, as deformation increases beyond the vonMises strain of 0.05, the shape of the work contour significantly deviates from that of Hill's yield locus. A prediction made by a viscoplastic self-consistent model is in better agreement with the experimental observation than the Hill yield locus with the isotropic work-hardening rule. However, none of the studied models matched the initial or evolving anisotropic behaviors of the interstitial-free steel measured by the augmented Marciniak experiment. PMID:28690400
Jeong, Y; Iadicola, M A; Gnäupel-Herold, T; Creuziger, A
2016-06-15
Constitutive behaviors of an interstitial-free steel sample were measured using an augmented Marciniak experiment. In these tests, multiaxial strain field data of the flat specimens were measured by the digital image correlation technique. In addition, the flow stress was measured using an X-ray diffractometer. The flat specimens in three different geometries were tested in order to achieve 1) balanced biaxial strain, and plane strain tests with zero strain in either 2) rolling direction or 3) transverse direction. The multiaxial stress and strain data were processed to obtain plastic work contours with reference to a uniaxial tension test along the rolling direction. The experimental results show that the mechanical behavior of the subjected specimen deviates significantly from isotropic behavior predicted by the von Mises yield criterion. The initial yield loci measured by a Marciniak tester is in good agreement with what is predicted by Hill's yield criterion. However, as deformation increases beyond the vonMises strain of 0.05, the shape of the work contour significantly deviates from that of Hill's yield locus. A prediction made by a viscoplastic self-consistent model is in better agreement with the experimental observation than the Hill yield locus with the isotropic work-hardening rule. However, none of the studied models matched the initial or evolving anisotropic behaviors of the interstitial-free steel measured by the augmented Marciniak experiment.
Itani, Lina Y; Cherry, Mohamad A; Araj, George F
2005-01-01
Rapid detection of Mycobacterium tuberculosis (MTB), especially multidrug-resistant strains, is of importance for prompt clinical management and initiation of public health control measures. Culture remains the "gold" standard in the confirmatory laboratory diagnosis of mycobacterial infections. The reliability of the automated radiometric BACTEC 460 TB (BACTEC) system for the rapid detection of mycobacteria in clinical specimens was evaluated and compared to the conventional culture on Lowenstein-Jensen (LJ) medium. All clinical specimens submitted for mycobacterial culture were processed and simultaneously cultured on both BACTEC broth medium and LJ solid medium. Acid-fast bacilli (AFB) smears were also performed on the sediments. Differentiation of mycobacterial isolates as MTB or Mycobacterium sp. other than tuberculosis (MOTT) was based on the BACTEC NAP test. All positive culture findings recovered between January 1997 and December 2003 were analyzed in this study. A total of 3300 specimens were tested of which 355 (10.7%) yielded positive cultures consisting of 233 (65.6%) MTB and 122 (34.4%) MOTT. The percentages of AFB smear-positive were 45% and 49% in clinical specimens yielding MTB & MOTT, respectively. Though several types of specimens were cultured, most isolates (72% of MTB & 91% of MOTT) were recovered from respiratory specimens. Overall, the BACTEC showed significantly higher mycobacteria recovery rate (91%) than LJ (77%). In terms of times to detection, BACTEC showed significantly shorter detection time of isolates than LJ for the overall (mean 9.6 days for BACTEC vs. 22.8 days for LJ) and for each category of AFB smear finding. The detection time is shortened for BACTEC with the increasing grade of smear positivity. BACTEC is substantially more sensitive, efficient and rapid than LJ in the laboratory diagnosis of mycobacterial infections. This system also provides rapid differentiation of MTB from MOTT and susceptibility test results on MTB. However, the simultaneous use of BACTEC and LJ is recommended to provide maximum optimal recovery of isolates from clinical specimens. The time-saving in BACTEC provides an excellent facility for physicians in patient management and to public health personnel for prompt initiation of infection control measures.
Review of specimen heating in mechanical tests at cryogenic temperatures
NASA Astrophysics Data System (ADS)
Ogata, T.; Yuri, T.; Ono, Y.
2014-01-01
At cryogenic temperatures near 4 K, a discontinuous deformation produces a large amount of specimen temperature rise that might bring significant changes in mechanical properties. The authors measured the specimen heating in tensile tests, fatigue test, and other tests in liquid helium for stainless steels and other materials. In this paper, we have measured the specimen temperature in high-cycle and low-cycle fatigue tests for stainless steels at various frequencies and stress levels and evaluated the testing conditions to keep the specimen at a specified temperature. We proposed maximum frequency in load-controlled fatigue tests for specified loading variables and a maximum strain rate in strain-controlled fatigue tests.
Code of Federal Regulations, 2010 CFR
2010-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
Code of Federal Regulations, 2013 CFR
2013-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
Code of Federal Regulations, 2014 CFR
2014-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
Code of Federal Regulations, 2012 CFR
2012-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
Code of Federal Regulations, 2011 CFR
2011-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
Compilation of reinforced carbon-carbon transatlantic abort landing arc jet test results
NASA Technical Reports Server (NTRS)
Milhoan, James D.; Pham, Vuong T.; Yuen, Eric H.
1993-01-01
This document consists of the entire test database generated to support the Reinforced Carbon-Carbon Transatlantic Abort Landing Study. RCC components used for orbiter nose cap and wing leading edge thermal protection were originally designed to have a multi-mission entry capability of 2800 F. Increased orbiter range capability required a predicted increase in excess of 3300 F. Three test series were conducted. Test series #1 used ENKA-based RCC specimens coated with silicon carbide, treated with tetraethyl orthosilicate, sealed with Type A surface enhancement, and tested at 3000-3400 F with surface pressure of 60-101 psf. Series #2 used ENKA- or AVTEX-based RCC, with and without silicon carbide, Type A or double Type AA surface enhancement, all impregnated with TEOS, and at temperatures from 1440-3350 F with pressures from 100-350 psf. Series #3 tested ENKA-based RCC, with and without silicon carbide coating. No specimens were treated with TEOS or sealed with Type A. Surface temperatures ranged from 2690-3440 F and pressures ranged from 313-400 psf. These combined test results provided the database for establishing RCC material single-mission-limit temperature and developing surface recession correlations used to predict mass loss for abort conditions.
NASA Technical Reports Server (NTRS)
Dolan, Thomas J
1942-01-01
Laboratory tests were made to obtain information on the load-resisting properties of X76S-T aluminum alloy when subjected to static, impact, and repeated loads. Results are presented from static-load test of unnotched specimens in tension and in torsion and of notched specimens in tension. Charpy impact values obtained from bend tests on notched specimens and tension impact values for both notched and unnotched specimens tested at several different temperatures are included. The endurance limits obtained from repeated bending fatigue tests made on three different types of testing machine are given for unnotched polished specimens, and the endurance limits of notched specimens subjected to six different ranges of bending stress are also reported. The results indicated that: (a) polished rectangular specimens had an endurance limit about 30 percent less than that obtained for round specimens; (b) a comparison of endurance limits obtained from tests on three different types of machine indicated that there was no apparent effect of speed of testing on the endurance limit for the range of speeds used (1,750 to 13,000 rpm). (c) the fatigue strength (endurance limit) of the X76S-T alloy was greatly decreased by the presence of a notch in the specimens; (d) no complete fractures of the entire specimens occurred in notched fatigue specimens when subjected to stress cycles for which the mean stress at the notch during the cycle was a compressive stress; for this test condition a microscopic cracking occurred near the root of the notch and was used as a criterion of failure of the specimen. (e) as the mean stress at the notch was decreased from a tensile (+) stress to a compressive (-) stress, it was found that the alternating stress that could be superimposed on the mean stress in the cycle without causing failure of the specimens was increased.
10 CFR 26.97 - Conducting an initial test for alcohol using a specimen of oral fluids.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Conducting an initial test for alcohol using a specimen of oral fluids. 26.97 Section 26.97 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.97 Conducting an initial test for alcohol using a specimen of oral...
10 CFR 26.97 - Conducting an initial test for alcohol using a specimen of oral fluids.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Conducting an initial test for alcohol using a specimen of oral fluids. 26.97 Section 26.97 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.97 Conducting an initial test for alcohol using a specimen of oral...
10 CFR 26.97 - Conducting an initial test for alcohol using a specimen of oral fluids.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Conducting an initial test for alcohol using a specimen of oral fluids. 26.97 Section 26.97 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.97 Conducting an initial test for alcohol using a specimen of oral...
10 CFR 26.97 - Conducting an initial test for alcohol using a specimen of oral fluids.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Conducting an initial test for alcohol using a specimen of oral fluids. 26.97 Section 26.97 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.97 Conducting an initial test for alcohol using a specimen of oral...
10 CFR 26.97 - Conducting an initial test for alcohol using a specimen of oral fluids.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Conducting an initial test for alcohol using a specimen of oral fluids. 26.97 Section 26.97 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.97 Conducting an initial test for alcohol using a specimen of oral...
NASA Technical Reports Server (NTRS)
Nettles, A. T.; Hodge, A. J.; Jackson, J. R.
2011-01-01
For any structure composed of laminated composite materials, impact damage is one of the greatest risks and therefore most widely tested responses. Typically, impact damage testing and analysis assumes that a solid object comes into contact with the bare surface of the laminate (the outer ply). However, most launch vehicle structures will have a thermal protection system (TPS) covering the structure for the majority of its life. Thus, the impact response of the material with the TPS covering is the impact scenario of interest. In this study, laminates representative of the composite interstage structure for the Ares I launch vehicle were impact tested with and without the planned TPS covering, which consists of polyurethane foam. Response variables examined include maximum load of impact, damage size as detected by nondestructive evaluation techniques, and damage morphology and compression after impact strength. Results show that there is little difference between TPS covered and bare specimens, except the residual strength data is higher for TPS covered specimens.
Preliminary burn and impact tests of hybrid polymeric composites. [preventing graphite fiber release
NASA Technical Reports Server (NTRS)
Tompkins, S. S.; Brewer, W. D.
1978-01-01
Free graphite fibers released into the environment from resin matrix composite components, as a result of fire and/or explosion, pose a potential hazard to electrical equipment. An approach to prevent the fibers from becoming airborne is to use hybrid composite materials which retain the fibers at the burn site. Test results are presented for three hybrid composites that were exposed to a simulation of an aircraft fire and explosion. The hybrid systems consisted of 16 plies of graphite-epoxy with two plies of Kevlar-, S-glass-, or boron-epoxy on each face. Two different test environments were used. In one environment, specimens were heated by convection only, and then impacted by a falling mass. In the other environment, specimens were heated by convection and by radiation, but were not impacted. The convective heat flux was about 100-120 kW/m in both environments and the radiative flux was about 110 kW/sq m.
Evaluation of Mycology Laboratory Proficiency Testing
Reilly, Andrew A.; Salkin, Ira F.; McGinnis, Michael R.; Gromadzki, Sally; Pasarell, Lester; Kemna, Maggi; Higgins, Nancy; Salfinger, Max
1999-01-01
Changes over the last decade in overt proficiency testing (OPT) regulations have been ostensibly directed at improving laboratory performance on patient samples. However, the overt (unblinded) format of the tests and regulatory penalties associated with incorrect values allow and encourage laboratorians to take extra precautions with OPT analytes. As a result OPT may measure optimal laboratory performance instead of the intended target of typical performance attained during routine patient testing. This study addresses this issue by evaluating medical mycology OPT and comparing its fungal specimen identification error rates to those obtained in a covert (blinded) proficiency testing (CPT) program. Identifications from 188 laboratories participating in the New York State mycology OPT from 1982 to 1994 were compared with the identifications of the same fungi recovered from patient specimens in 1989 and 1994 as part of the routine procedures of 88 of these laboratories. The consistency in the identification of OPT specimens was sufficient to make accurate predictions of OPT error rates. However, while the error rates in OPT and CPT were similar for Candida albicans, significantly higher error rates were found in CPT for Candida tropicalis, Candida glabrata, and other common pathogenic fungi. These differences may, in part, be due to OPT’s use of ideal organism representatives cultured under optimum growth conditions. This difference, as well as the organism-dependent error rate differences, reflects the limitations of OPT as a means of assessing the quality of routine laboratory performance in medical mycology. PMID:10364601
Selby, John C; Shannon, Mark A
2007-09-01
Details are given for the design, calibration, and operation of an apparatus for measuring the finite load-deformation behavior of a sheet of living epithelial cells cultured on a mesoscopic freestanding elastomer membrane, 10 microm thick and 5 mm in diameter. Although similar in concept to bulge tests used to investigate the mechanical properties of micromachined thin films, cell-elastomer composite diaphragm inflation tests pose a unique set of experimental challenges. Composite diaphragm (CD) specimens are extremely compliant (E<50 kPa), experience large displacements when subject to small inflation pressures (approximately 100 Pa), and must be continuously immersed in a bath of liquid culture medium during the acquisition of load-deformation measurements. Given these considerations, we have constructed an inflation apparatus consisting of an air-piston-cylinder pump integrated with a modular specimen mounting fixture that constitutes a horizontally semi-infinite reservoir of liquid culture medium. In a deformation-controlled inflation test, pressurized air is used to inflate a CD specimen into the liquid reservoir with minimum disturbance of the liquid-air interface. Piston displacements and absolute pump chamber air pressures are utilized as feedback to cycle the displaced (or inflated) CD volume V in a 0.05 Hz triangular or sinusoidal wave form (V(MIN)=0 microl, V(MAX)
Hardie, Diana Ruth; Korsman, Stephen N; Hsiao, Nei-Yuan; Morobadi, Molefi Daniel; Vawda, Sabeehah; Goedhals, Dominique
2017-01-01
In South Africa where the prevalence of HIV infection is very high, 4th generation HIV antibody/p24 antigen combo immunoassays are the tests of choice for laboratory based screening. Testing is usually performed in clinical pathology laboratories on automated analysers. To investigate the cause of false positive results on 4th generation HIV testing platforms in public sector laboratories, the performance of two automated platforms was compared in a clinical pathology setting, firstly on routine diagnostic specimens and secondly on known sero-negative samples. Firstly, 1181 routine diagnostic specimens were sequentially tested on Siemens and Roche automated 4th generation platforms. HIV viral load, western blot and follow up testing were used to determine the true status of inconclusive specimens. Subsequently, known HIV seronegative samples from a single donor were repeatedly tested on both platforms and an analyser was tested for surface contamination with HIV positive serum to identify how suspected specimen contamination could be occurring. Serial testing of diagnostic specimens yielded 163 weakly positive or discordant results. Only 3 of 163 were conclusively shown to indicate true HIV infection. Specimen contamination with HIV antibody was suspected, based on the following evidence: the proportion of positive specimens increased on repeated passage through the analysers; viral loads were low or undetectable and western blots negative or indeterminate on problem specimens; screen negative, 2nd test positive specimens tested positive when reanalysed on the screening assay; follow up specimens (where available) were negative. Similarly, an increasing number of known negative specimens became (repeatedly) sero-positive on serial passage through one of the analysers. Internal and external analyser surfaces were contaminated with HIV serum, evidence that sample splashes occur during testing. Due to the extreme sensitivity of these assays, contamination with minute amounts of HIV antibody can cause a negative sample to test positive. Better contamination control measures are needed on analysers used in clinical pathology environments, especially in regions where HIV sero-prevalence is high.
Hexavalent Chromium IV-Free Primer Development
NASA Technical Reports Server (NTRS)
Alldredge, Michael J.; Buck, Amy L.
2015-01-01
Primer materials provide corrosion protection for metal parts as well as an increased adhesion between metallic substrates and thermal protection systems (TPSs). Current primers for use in cryogenic applications contain hexavalent chromium. This hexavalent chromium provides excellent corrosion protection even in a cryogenic environment, but it is a carcinogen that requires special equipment and waste control procedures to use. The hazardous nature of hexavalent chromium makes it an obsolescence risk in the future. This study included two phases of evaluation. Thirteen primers were initially identified as candidates and twelve of those primers were tested in phase 1. Four of the best performing candidates from phase 1 continued into phase 2 testing. Phase 1 testing consisted mostly of liquid constituent and physical property testing. Cryoflex and salt fog testing were included in phase 1 because of their importance to the overall success of a candidate material. Phase 2 consisted of physical, thermal, and mechanical properties for nominally processed and fabricated specimens.
An Electromagnetic Tool for Damping and Fatigue Analysis
2004-03-01
Serway , Raymond A . Physics For Scientists & Engineers (3rd Edition). Philadelphia: Saunders College Publishing, 1990. 15. Kurtus, Ron...system was initially designed to reduce the time and manpower required to characterize damping treatments. It is based on a digitally controlled...the capability to study fatigue under a free boundary condition. The system consists of a test specimen suspended by a pendulum to closely
Sato, Eriko; Hagihara, Takashi; Matsumoto, Akikazu
2012-04-01
Block copolymers consisting of readily degradable polyperoxides and non-degradable vinyl polymers as the block segments were successfully synthesized by reversible chain transfer catalyzed polymerization, which is one of living radical polymerization techniques. The block copolymers showed characteristic morphology and wettability being different from the polymer blends. When block copolymers containing polyperoxide and polymethacrylate blocks were heated below 150 °C, the polyperoxide blocks were completely degraded and the polymethacrylate blocks were recovered without degradation. Block copolymers containing a poly(2-ethylhexyl methacrylate) block were then investigated as a dismantlable adhesion material, which requires adequate bonding strength during use and easy debonding on demand. Among the several block copolymers, the one consisting of poly(2-ethylhexyl methacrylate) and polyperoxide from methyl sorbate (PPMS) (M(n) = 4900) exhibited good performance as a pressure-sensitive adhesive (PSA). After heating the test specimens in a temperature range from 60 to 100 °C, PSA performance, which was evaluated by 180° peel strength and shear holding power measurements, was significantly diminished. Especially, after heating at 100 °C for 1 h, spontaneous debonding of some test specimens was observed because of the evolution of volatile acetaldehyde from PPMS.
Design and fabrication of titanium multi-wall Thermal Protection System (TPS) test panels
NASA Technical Reports Server (NTRS)
Blair, W.; Meaney, J. E., Jr.; Rosenthal, H. A.
1980-01-01
A titanium multiwall thermal protection system panel was designed. The panel is a nine sheet sandwich structure consisting of an upper and lower face sheet; four dimpled sheets, three septum sheets, and clips for attachment to a vehicle structure. An acceptable fabrication process was developed, and the panel design was verified through mechanical and thermal testing of component specimens. A design was completed which takes into consideration fabrication techniques, thermal properties, mechanical properties, and materials availability.
3D-Printed specimens as a valuable tool in anatomy education: A pilot study.
Garas, Monique; Vaccarezza, Mauro; Newland, George; McVay-Doornbusch, Kylie; Hasani, Jamila
2018-06-06
Three-dimensional (3D) printing is a modern technique of creating 3D-printed models that allows reproduction of human structures from MRI and CT scans via fusion of multiple layers of resin materials. To assess feasibility of this innovative resource as anatomy educational tool, we conducted a preliminary study on Curtin University undergraduate students to investigate the use of 3D models for anatomy learning as a main goal, to assess the effectiveness of different specimen types during the sessions and personally preferred anatomy learning tools among students as secondary aim. The study consisted of a pre-test, exposure to test (anatomical test) and post-test survey. During pre-test, all participants (both without prior experience and experienced groups) were given a brief introduction on laboratory safety and study procedure thus participants were exposed to 3D, wet and plastinated specimens of the heart, shoulder and thigh to identify the pinned structures (anatomical test). Then, participants were provided a post-test survey containing five questions. In total, 23 participants completed the anatomical test and post-test survey. A larger number of participants (85%) achieved right answers for 3D models compared to wet and plastinated materials, 74% of population selected 3D models as the most usable tool for identification of pinned structures and 45% chose 3D models as their preferred method of anatomy learning. This preliminary small-size study affirms the feasibility of 3D-printed models as a valuable asset in anatomy learning and shows their capability to be used adjacent to cadaveric materials and other widely used tools in anatomy education. Copyright © 2018 Elsevier GmbH. All rights reserved.
Using a surrogate contact pair to evaluate polyethylene wear in prosthetic knee joints.
Sanders, Anthony P; Lockard, Carly A; Weisenburger, Joel N; Haider, Hani; Raeymaekers, Bart
2016-01-01
With recent improvements to the properties of ultra-high molecular weight polyethylene (UHMWPE) used in joint replacements, prosthetic knee and hip longevity may extend beyond two decades. However, it is difficult and costly to replicate such a long in vivo lifetime using clinically relevant in vitro wear testing approaches such as walking gait joint simulators. We advance a wear test intermediate in complexity between pin-on-disk and knee joint simulator tests. The test uses a surrogate contact pair, consisting of a surrogate femoral and tibial specimen that replicate the contact mechanics of any full-scale knee condyle contact pair. The method is implemented in a standard multi-directional pin-on-disk wear test machine, and we demonstrate its application via a two-million-cycle wear test of three different UHMWPE formulations. Further, we demonstrate the use of digital photography and image processing to accurately quantify fatigue damage based on the reduced transmission of light through a damage area in a UHMWPE specimen. The surrogate contact pairs replicate the knee condyle contact areas within -3% to +12%. The gravimetric wear test results reflect the dose of crosslinking radiation applied to the UHMWPE: 35 kGy yielded a wear rate of 7.4 mg/Mcycles, 55 kGy yielded 1.0 mg/Mcycles, and 75 kGy (applied to a 0.1% vitamin E stabilized UHMWPE) yielded 1.5 mg/Mcycles. A precursor to spalling fatigue is observed and precisely measured in the radiation-sterilized (35 kGy) and aged UHMWPE specimen. The presented techniques can be used to evaluate the high-cycle fatigue performance of arbitrary knee condyle contact pairs under design-specific contact stresses, using existing wear test machines. This makes the techniques more economical and well-suited to standardized comparative testing. © 2015 Wiley Periodicals, Inc.
Thermal fatigue and oxidation data of TAZ-8A and M22 alloys and variations
NASA Technical Reports Server (NTRS)
Hofer, K. E.; Humphreys, V. E.
1981-01-01
Thermal fatigue and oxidation data were obtained on 36 specimens, representing 18 distinct variations (including the base systems) of TAZ-8A and M22 alloys. Double-edge wedge specimens for these systems were cycled between fluidized beds maintained at 1088 C and 316 C with a 180 s immersion in each bed. The systems included alloys TAZ-8A, M22, and 16 variations of these alloys. Each alloy variation consisted of a unique composition with an alternation in the percentage of carbon (C1 and C2), molydenum (M1 and M2), tungsten (W1 and W2), columbium (CB1, CB2, and CB3), tantalium (T1, T2, and T3), or boron (B1, B2, and B3) present. All of the alloys showed little weight change due to oxidation compared with other alloys previously tested in fluidized beds. Only both C1 alloy variation specimens survived 3500 cycles without cracking in the small radius, although substantial cracks were present, emanating from the end notches which were used for holding the specimens.
Tensile and fatigue behavior of polymer composites reinforced with superelastic SMA strands
NASA Astrophysics Data System (ADS)
Daghash, Sherif M.; Ozbulut, Osman E.
2018-06-01
This study explores the use of superelastic shape memory alloy (SMA) strands, which consist of seven individual small-diameter wires, in an epoxy matrix and characterizes the tensile and fatigue responses of the developed SMA/epoxy composites. Using a vacuum assisted hand lay-up technique, twelve SMA fiber reinforced polymer (FRP) specimens were fabricated. The developed SMA-FRP composites had a fiber volume ratio of 50%. Tensile response of SMA-FRP specimens were characterized under both monotonic loading and increasing amplitude loading and unloading cycles. The degradation in superelastic properties of the developed SMA-FRP composites during fatigue loading at different strain amplitudes was investigated. The effect of loading rate on the fatigue response of SMA-FRP composites was also explored. In addition, fractured specimens were examined using the scanning electron microscopy (SEM) technique to study the failure mechanisms of the tested specimens. A good interfacial bonding between the SMA strands and epoxy matrix was observed. The developed SMA-FRP composites exhibited good superelastic behavior at different strain amplitudes up to at least 800 cycle after which significant degradation occurred.
NASA Astrophysics Data System (ADS)
Takatsuji, Toshiyuki; Tanaka, Ken-ichi
1996-06-01
A procedure is derived by which sensory attributes can be scaled as a function of various physical and/or chemical properties of the object to be tested. This procedure consists of four successive steps: (i) design and experiment, (ii) fabrication of specimens according to the design parameters, (iii) assessment of a sensory attribute using sensory evaluation and (iv) derivation of the relationship between the parameters and the sensory attribute. In these steps an experimental design using orthogonal arrays, analysis of variance and regression analyses are used strategically. When a specimen with the design parameters cannot be physically fabricated, an alternative specimen having parameters closest to the design is selected from a group of specimens which can be physically made. The influence of the deviation of actual parameters from the desired ones is also discussed. A method of confirming the validity of the regression equation is also investigated. The procedure is applied to scale the sensory sharpness of kitchen knives as a function of the edge angle and the roughness of the cutting edge.
Nondestructive Evaluation of Adhesively Bonded Joints
NASA Technical Reports Server (NTRS)
Nayeb-Hashemi, Hamid; Rossettos, J. N.
1997-01-01
The final report consists of 5 published papers in referred journals and a technical letter to the technical monitor. These papers include the following: (1) Comparison of the effects of debonds and voids in adhesive; (2) On the peak shear stresses in adhesive joints with voids; (3) Nondestructive evaluation of adhesively bonded joints by acousto-ultrasonic technique and acoustic emission; (4) Multiaxial fatigue life evaluation of tubular adhesively bonded joints; (5) Theoretical and experimental evaluation of the bond strength under peeling loads. The letter outlines the progress of the research. Also included is preliminary information on the study of nondestructive evaluation of composite materials subjected to localized heat damage. The investigators studied the effects of localized heat on unidirectional fiber glass epoxy composite panels. Specimens of the fiber glass epoxy composites were subjected to 400 C heat for varying lengths of time. The specimens were subjected to nondestructive tests. The specimens were then pulled to their failure and acoustic emission of these specimens were measured. The analysis of the data was continuing as of the writing of the letter, and includes a finite element stress analysis of the problem.
Method and apparatus for nondestructive testing. [using high frequency arc discharges
NASA Technical Reports Server (NTRS)
Hoop, J. M. (Inventor)
1974-01-01
High voltage is applied to an arc gap adjacent to a test specimen to develop a succession of high frequency arc discharges. Those high frequency arc discharges generate pulses of ultrasonic energy within the test specimen without requiring the arc discharges to contact that test specimen and without requiring a coupling medium. Those pulses can be used for detection of flaws and measurements of certain properties and stresses within the test specimen.
Scale-Up of an Human Papillomavirus Testing Implementation Program in El Salvador
Cremer, Miriam; Maza, Mauricio; Alfaro, Karla; Morales Velado, Mario; Felix, Juan; Castle, Philip E.; Kim, Jane; Gage, Julia C.
2017-01-01
Objective The Cervical Cancer Prevention in El Salvador is a demonstration project to introduce a lower-cost human papillomavirus (HPV)-DNA test into a public sector project. Started in October 2012, The Cervical Cancer Prevention in El Salvador consists of 3 phases and will ultimately screen 30,000 women. Results of phase 2 of the project are presented. The objective of this project was to compare colposcopy and noncolposcopy-based management for HPV-positive women. Material and Methods In phase 2, a total of 8,050 women, aged 30 to 49 years, were screened; 6,761 provided both self- and provider-collected specimens and 1,289 provided only provider-testing specimens. HPV results from self-collected specimens were not used in clinical management decisions. Women with provider-collected HPV-positive results were treated based on the strategy assigned to their community; the strategy was colposcopy management (CM) or screen-and-treat (ST) management if they were cryotherapy eligible or colposcopy if not eligible. Outcomes were assessed 6 months after screening. Results Overall, 489 (12.3%) of 3,963 women receiving CM and 465 (11.4%) of 4,087 women receiving ST tested HPV positive. In the CM cohort, 216 (44.2%) of 489 completed their intervention (203 treated, 11 diagnosed negative, 2 pregnant). In the ST cohort, 411 (88.4%) of 465 completed their intervention (407 treated, 2 diagnosed negative, 1 pregnant). Overall agreement between HPV test results from self-collected and provider-collected specimens was 93.7%, with a κ value of 0.70 (95% CI = 0.68–0.73). Conclusions Human papillomavirus testing with ST management resulted in an approximately twice completion rate compared with CM management. Agreement between self- and provider-based sampling was good and might be used to extend screening to women in areas that are more difficult to reach. PMID:27922905
Kanie, Takahito; Arikawa, Hiroyuki; Fujii, Koichi; Ban, Seiji
2002-09-01
This study examined the effects of the position and the number of woven glass fibers on the flexural strength, flexural modulus, and toughness of reinforced denture base resin. The woven glass fiber consisted of 1-4 laminated sheets. Chemical curing was used to polymerize three types of 4-mm-thick test specimens: fibers in compresrion, fibers in the center, and fibers in tension. Unreinforced specimens were produced as controls. A three-point flexural test was performed and the woven glass fiber content was calculated after the woven glass fiber was fired. The best results were obtained when the woven glass fiber was incorporated outside the base resin under tension, thereby increasing the flexural strength and flexural modulus. Furthermore, the denture base resin reinforced with woven glass fiber was made tougher by increasing the number of woven glass fibers incorporated into the portion under tension.
NASA Technical Reports Server (NTRS)
Gyekenyesi, Andrew L.; Gastelli, Michael G.; Ellis, John R.; Burke, Christopher S.
1995-01-01
An experimental study was conducted to investigate the mechanical behavior of a T650-35/AMB21 eight-harness satin weave polymer composite system. Emphasis was placed on the development and refinement of techniques used in elevated temperature uniaxial PMC testing. Issues such as specimen design, gripping, strain measurement, and temperature control and measurement were addressed. Quasi-static tensile and fatigue properties (R(sub sigma) = 0.1) were examined at room and elevated temperatures. Stiffness degradation and strain accumulation during fatigue cycling were recorded to monitor damage progression and provide insight for future analytical modeling efforts. Accomplishments included an untabbed dog-bone specimen design which consistently failed in the gage section, accurate temperature control and assessment, and continuous in-situ strain measurement capability during fatigue loading at elevated temperatures. Finally, strain accumulation and stiffness degradation during fatigue cycling appeared to be good indicators of damage progression.
Advanced manufacturing development of a composite empennage component for L-1011 aircraft
NASA Technical Reports Server (NTRS)
1979-01-01
Work on process verification and tooling development continued. The cover process development was completed with the decision to proceed with low resin content prepreg material (34 + or - 3% by weight) in the fabrication of production readiness verification test (PRVT) specimens and the full-scale covers. The structural integrity of the cover/joint design was verified with the successful test of the cover attachment to fuselage ancillary test specimen (H25). Failure occurred, as predicted, in the skin panel away from the fuselage joint at 141 percent of the design ultimate load. With the successful completion of the H25 test, the PRVT cover specimens, which are identical to the H25 ancillary test specimen, were cleared for production. Eight of the twenty cover specimens were fabricated and are in preparation for test. All twenty of the PRVT spar specimens were fabricated and also were prepared for test. The environmental chambers used in the durability test of ten cover and ten spar PRVT specimens were completed and installed in the load reaction frames.
10 CFR 26.165 - Testing split specimens and retesting single specimens.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Testing split specimens and retesting single specimens. 26.165 Section 26.165 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Laboratories... laboratory or maintained in secure storage at the licensee testing facility, as required by § 26.135(a) and...
Noncontact Acousto-Ultrasonic Testing With Laser Beams
NASA Technical Reports Server (NTRS)
Huber, Robert D.; Green, Robert E., Jr.
1994-01-01
Laser beams used to excite and detect acoustic waves in specimens. Laser/acousto-ultrasonic technique entails no mechanical contact between specimens and testing apparatus. Apparatus located at relatively large distances (meters) from specimens, making it possible to test specimens too hot for contact measurements or located in inaccessible places, vacuums, or hostile environments.
NASA Technical Reports Server (NTRS)
Yun, Gunjin; Abdullah, A. B. M.; Binienda, Wieslaw; Krause, David L.; Kalluri, Sreeramesh
2014-01-01
A vibration-based testing methodology has been developed that will assess fatigue behavior of the metallic material of construction for the Advanced Stirling Convertor displacer (planar) spring component. To minimize the testing duration, the test setup is designed for base-excitation of a multiplespecimen arrangement, driven in a high-frequency resonant mode; this allows completion of fatigue testing in an accelerated period. A high performance electro-dynamic exciter (shaker) is used to generate harmonic oscillation of cantilever beam specimens, which are clasped on the shaker armature with specially-designed clamp fixtures. The shaker operates in closed-loop control with dynamic specimen response feedback provided by a scanning laser vibrometer. A test coordinator function synchronizes the shaker controller and the laser vibrometer to complete the closed-loop scheme. The test coordinator also monitors structural health of the test specimens throughout the test period, recognizing any change in specimen dynamic behavior. As this may be due to fatigue crack initiation, the test coordinator terminates test progression and then acquires test data in an orderly manner. Design of the specimen and fixture geometry was completed by finite element analysis such that peak stress does not occur at the clamping fixture attachment points. Experimental stress evaluation was conducted to verify the specimen stress predictions. A successful application of the experimental methodology was demonstrated by validation tests with carbon steel specimens subjected to fully-reversed bending stress; high-cycle fatigue failures were induced in such specimens using higher-than-prototypical stresses
Device for measuring hole elongation in a bolted joint
NASA Technical Reports Server (NTRS)
Wichorek, Gregory R. (Inventor)
1987-01-01
A device to determine the operable failure mode of mechanically fastened lightweight composite joints by measuring the hole elongation of a bolted joint is disclosed. The double-lap joint test apparatus comprises a stud, a test specimen having a hole, two load transfer plates, and linear displacement measuring instruments. The test specimen is sandwiched between the two load transfer plates and clamped together with the stud. Spacer washers are placed between the test specimen and each load transfer plate to provide a known, controllable area for the determination of clamping forces around the hole of the specimen attributable to bolt torque. The spacer washers also provide a gap for the mounting of reference angles on each side of the test specimen. Under tensile loading, elongation of the hole of the test specimen causes the stud to move away from the reference angles. This displacement is measured by the voltage output of two linear displacement measuring instruments that are attached to the stud and remain in contact with the reference angles throughout the tensile loading. The present invention obviates previous problems in obtaining specimen deformation measurements by monitoring the reference angles to the test specimen and the linear displacement measuring instruments to the stud.
Ply-level failure analysis of a graphite/epoxy laminate under bearing-bypass loading
NASA Technical Reports Server (NTRS)
Naik, R. A.; Crews, J. H., Jr.
1988-01-01
A combined experimental and analytical study was conducted to investigate and predict the failure modes of a graphite/epoxy laminate subjected to combined bearing and bypass loading. Tests were conducted in a test machine that allowed the bearing-bypass load ratio to be controlled while a single-fastener coupon was loaded to failure in either tension or compression. Onset and ultimate failure modes and strengths were determined for each test case. The damage-onset modes were studied in detail by sectioning and micrographing the damaged specimens. A two-dimensional, finite-element analysis was conducted to determine lamina strains around the bolt hole. Damage onset consisted of matrix cracks, delamination, and fiber failures. Stiffness loss appeared to be caused by fiber failures rather than by matrix cracking and delamination. An unusual offset-compression mode was observed for compressive bearing-bypass laoding in which the specimen failed across its width along a line offset from the hole. The computed lamina strains in the fiber direction were used in a combined analytical and experimental approach to predict bearing-bypass diagrams for damage onset from a few simple tests.
Ply-level failure analysis of a graphite/epoxy laminate under bearing-bypass loading
NASA Technical Reports Server (NTRS)
Naik, R. A.; Crews, J. H., Jr.
1990-01-01
A combined experimental and analytical study was conducted to investigate and predict the failure modes of a graphite/epoxy laminate subjected to combined bearing and bypass loading. Tests were conducted in a test machine that allowed the bearing-bypass load ratio to be controlled while a single-fastener coupon was loaded to failure in either tension or compression. Onset and ultimate failure modes and strengths were determined for each test case. The damage-onset modes were studied in detail by sectioning and micrographing the damaged specimens. A two-dimensional, finite-element analysis was conducted to determine lamina strains around the bolt hole. Damage onset consisted of matrix cracks, delamination, and fiber failures. Stiffness loss appeared to be caused by fiber failures rather than by matrix cracking and delamination. An unusual offset-compression mode was observed for compressive bearing-bypass loading in which the specimen failed across its width along a line offset from the hole. The computed lamina strains in the fiber direction were used in a combined analytical and experimental approach to predict bearing-bypass diagrams for damage onset from a few simple tests.
Karlinsey, Robert L; Mackey, Allen C; Stookey, George K; Pfarrer, Aaron M
2009-06-01
To determine the fluoride dose response of experimental NaF dentifrices containing a prospective calcium phosphate technology, along with the corresponding relative enamel and dentin abrasion values. 3 mm diameter bovine enamel specimens were mounted, ground and polished, and softened in a carbopol-lactic acid solution (pH = 5.0) for 36 hours at 37 degrees C. Specimens were then measured for baseline Vickers microhardness and stratified (N = 18, mean VHN = 33) into eight groups. These groups consisted of a placebo paste, four test dentifrices (A, B, C, D) with three of the four (A, B, C) containing a promising calcium phosphate ingredient, Crest Cavity Protection, MI Paste Plus, and PreviDent Booster 5000. The groups were cycled in a lesion reversal pH cycling model consisting of four 2-minute treatment periods (diluted 1:3 with DI water) and one 4-hour acid challenge (carbopol-lactic acid, pH = 5.0) per day. Between these events, specimens were immersed in artificial saliva (pH = 7.0). After 20 days of cycling, the specimens were microdrilled and analyzed for fluoride content, and also measured for Vickers surface microhardness after 10 and 20 days of cycling and after a 2-hour and 16-hour post-cycle acid challenge (carbopol-lactic acid, pH = 5.0). Separately, relative dentin and enamel abrasion (RDA and REA) were performed using the ADA recommended radiotracer method. A fluoride dose response was observed for the test dentifrices after 10 and 20 days of pH cycling, with test dentifrice C promoting the highest remineralization among the groups while both the MI Paste Plus and PreviDent systems provide the least remineralization (one-way ANOVA, SNK, P < 0.05). With respect to enamel fluoride uptake, the group facilitating the highest incorporation of fluoride into the enamel lesion was test dentifrice C, while the least effective NaF system was the MI Paste Plus (one-way ANOVA, SNK, P < 0.05). In terms of formulation abrasion, the REA scores were similar among the test dentifrices, MI Paste Plus, and PreviDent and compared favorably to the ADA reference material score (one-way ANOVA, SNK, P < 0.05); relative to the ADA reference material RDA score, the data indicate that MI Paste Plus was essentially non-abrasive, while PreviDent was significantly more abrasive to dentin (one-way ANOVA, SNK, P < 0.05). Altogether, these data show the developmental test dentifrices demonstrate a fluoride dose response and show great promise in remineralizing white-spot enamel lesions relative to MI Paste Plus and PreviDent.
Ten Deg Off-Axis Test for Shear Properties in Fiber Composites
NASA Technical Reports Server (NTRS)
Chamis, C. C.; Sinclair, J. H.
1977-01-01
A combined theoretical and experimental investigation was conducted to assess the suitability of the 10 deg off-axis tensile test specimen for the intralaminar shear characterization of unidirectional composites. Composite mechanics, a combined-stress failure criterion, and a finite variation across the specimen width and the relative stress and strain magnitudes at the 10 deg plane. Strain gages were used to measure the strain variation across the specimen width at specimen midlength and near the end tabs. Specimens from Mod-I/epoxy, T-300/epoxy, and S-glass/epoxy were used in the experimental program. It was found that the 10 deg off-axis tensile test specimen is suitable for intralaminar shear characterization, and it is recommended that it should be considered as a possible standard test specimen for such a characterization.
NASA Technical Reports Server (NTRS)
Raju, B. B.; Camarda, C. J.; Cooper, P. A.
1979-01-01
Seventy-nine graphite/polyimide compression specimens were tested to investigate experimentally the IITRI test method for determining compressive properties of composite materials at room and elevated temperatures (589 K (600 F)). Minor modifications were made to the standard IITRI fixture and a high degree of precision was maintained in specimen fabrication and load alignment. Specimens included four symmetric laminate orientations. Various widths were tested to evaluate the effect of width on measured modulus and strength. In most cases three specimens of each width were tested at room and elevated temperature and a polynomial regression analysis was used to reduce the data. Scatter of replicate tests and back-to-back strain variations were low, and no specimens failed by instability. Variation of specimen width had a negligible effect on the measured ultimate strengths and initial moduli of the specimens. Measured compressive strength and stiffness values were sufficiently high for the material to be considered a usable structural material at temperatures as high as 589 K (600 F).
Effect of Heat-Affected Zone on Spot Weldability in Automotive Ultra High Strength Steel Sheet
NASA Astrophysics Data System (ADS)
Nagasaka, Akihiko; Naito, Junya; Chinzei, Shota; Hojo, Tomohiko; Horiguchi, Katsumi; Shimizu, Yuki; Furusawa, Takuro; Kitahara, Yu
Effect of heat-affected zone (HAZ) on spot weldability in automotive hot stamping (HS) steel sheet was investigated for automotive applications. Tensile test was performed on a tensile testing machine at a crosshead speed of 3 mm/min, using spot welded test specimen (Parallel length: 60 mm, Width: 20 mm, Thickness: 1.4 mm, Tab: 20×20 mm). The spot welding test was carried out using spot welded test specimen with welding current (I) of 6.3 kA to 9.5 kA. Hardness was measured with the dynamic ultra micro Vickers hardness tester. In HS steel, has very high strength of 1 500 MPa, tensile strength (TS) and total elongation (TEl) of the spot welded test specimen of HS steel were lower than those of base metal test specimen. The spot welded test specimen broke in the weld. The Vickers hardnesses (HVs) of base metal and fusion zone of hot stamping steel were around HV500. In addition, the hardness of HAZ was under HV300. The difference of hardness between fusion zone and HAZ was around HV200. The hardness distribution acted as a notch. On the other hand, in dual phase (DP) steel, has low strength of 590 MPa, the TS of spot welded test specimen of DP steel was the same as the base metal test specimen because of the breaking of base metal. The TEl of the spot welded test specimen of DP steel was smaller than that of base metal test specimen. In the spot welded test specimen of DP steel, the hardness of base metal was around HV200 and the fusion zone was around HV500. The hardness distribution did not act as a notch. The difference in hardness between base metal and HAZ acted on a crack initiation at HAZ softening.
Brumback, B G; Farthing, P G; Castellino, S N
1993-12-01
Specimens from skin lesions were examined simultaneously for herpes simplex virus (HSV) and varicella-zoster virus (VZV) by direct specimen testing and shell vial culture in single-test systems. For direct testing, cells in a single specimen well were stained with a combination direct-indirect immunofluorescence stain by using two fluorescent tags. A total of 203 fresh specimens were tested in parallel. Of these, 100 specimens contained too few cells for the direct VZV comparison and 91 contained too few cells for the HSV comparison. After these specimens were eliminated, the sensitivities and specificities, respectively, of the dual direct test were 86.1 and 97.3% for HSV compared with single culture and 92.2 and 100% for VZV compared with single direct testing. Shell vial monolayers in the combined cultures were stained for both viruses by the same method. A total of 305 fresh specimens were cultured in parallel by dual- and single-culture methods. The sensitivities and specificities, respectively, of the combined culture compared with separate cultures were 100 and 98.4% for HSV and 87.9 and 99.2% for VZV. The combined methods gave a performance comparable to those of single tests, required less specimen volume, and were less costly to perform.
Geotechnical characterization of a Municipal Solid Waste Incineration Ash from a Michigan monofill.
Zekkos, Dimitrios; Kabalan, Mohammad; Syal, Sita Marie; Hambright, Matt; Sahadewa, Andhika
2013-06-01
A field and laboratory geotechnical characterization study of a Municipal Solid Waste Incineration Ash disposed of at the Carleton Farms monofill in Michigan was performed. Field characterization consisted of field observations, collection of four bulk samples and performance of shear wave velocity measurements at two locations. Laboratory characterization consisted of basic geotechnical characterization, i.e., grain size distribution, Atterberg limits, specific gravity tests, compaction tests as well as moisture and organic content assessment followed by direct shear and triaxial shear testing. The test results of this investigation are compared to results in the literature. The grain size distribution of the samples was found to be very similar and consistent with the grain size distribution data available in the literature, but the compaction characteristics were found to vary significantly. Specific gravities were also lower than specific gravities of silicic soils. Shear strengths were higher than typically reported for sandy soils, even for MSWI ash specimens at a loose state. Strain rate was not found to impact the shear resistance. Significant differences in triaxial shear were observed between a dry and a saturated specimen not only in terms of peak shear resistance, but also in terms of stress-strain response. In situ shear wave velocities ranged from 500 to 800 m/s at a depth of about 8m, to 1100-1200 m/s at a depth of 50 m. These high shear wave velocities are consistent with field observations indicating the formation of cemented blocks of ash with time, but this "ageing" process in MSWI ash is still not well understood and additional research is needed. An improved understanding of the long-term behavior of MSWI ash, including the effects of moisture and ash chemical composition on the ageing process, as well as the leaching characteristics of the material, may promote unbound utilization of the ash in civil infrastructure. Copyright © 2013 Elsevier Ltd. All rights reserved.
Mechanical characterization of an additively manufactured Inconel 718 theta-shaped specimen
Cakmak, Ercan; Watkins, Thomas R.; Bunn, Jeffrey R.; ...
2015-11-20
Two sets of “theta”-shaped specimens were additively manufactured with Inconel 718 powders using an electron beam melting technique with two distinct scan strategies. Light optical microscopy, mechanical testing coupled with a digital image correlation (DIC) technique, finite element modeling, and neutron diffraction with in situ loading characterizations were conducted. The cross-members of the specimens were the focus. Light optical micrographs revealed that different microstructures were formed with different scan strategies. Ex situ mechanical testing revealed each build to be stable under load until ductility was observed on the cross-members before failure. The elastic moduli were determined by forming a correlationmore » between the elastic tensile stresses determined from FEM, and the elastic strains obtained from DIC. The lattice strains were mapped with neutron diffraction during in situ elastic loading; and a good correlation between the average axial lattice strains on the cross-member and those determined from the DIC analysis was found. Lastly, the spatially resolved stresses in the elastic deformation regime are derived from the lattice strains and increased with applied load, showing a consistent distribution along the cross-member.« less
Chauhan, Kiran P; Trivedi, Amit P; Patel, Dharmik; Gami, Bhakti; Haridas, N
2014-10-01
Quality can be defined as the ability of a product or service to satisfy the needs and expectations of the customer. Laboratories are more focusing on technical and analytical quality for reliability and accuracy of test results. Patients and clinicians however are interested in rapid, reliable and efficient service from laboratory. Turn around time (TAT), the timeliness with which laboratory personnel deliver test results, is one of the most noticeable signs of laboratory service and is often used as a key performance indicator of laboratory performance. This study is aims to provide clue for laboratory TAT monitoring and root cause analysis. In a 2 year period a total of 75,499 specimens of outdoor patient department were monitor, of this a total of 4,142 specimens exceeded TAT. With consistent efforts to monitor, root cause analysis and corrective measures, we are able to decreased the specimens exceeding TAT from 7-8 to 3.7 %. Though it is difficult task to monitor TAT with the help of laboratory information system, real time documentation and authentic data retrievable, along with identification of causes for delays and its remedial measures, improve laboratory TAT and thus patient satisfaction.
Guarner, Jeannette; Street, Cassandra; Matlock, Margaret; Cole, Lisa; Brierre, Francoise
2017-03-01
Consolidation of laboratories has left many hospitals and satellite laboratories with minimal microbiologic testing. In many hospitals and satellite laboratories, Gram stains on primary specimens are still performed despite difficultly in maintaining proficiency. To maintain Gram stain proficiency at a community 450-bed hospital with an active emergency room we designed bimonthly challenges that require reporting Gram staining and morphology of different organisms. The challenges consist of five specimens prepared by the reference microbiology laboratory from cultures and primary specimens. Twenty to 23 medical laboratory scientists participate reading the challenges. Results from the challenges are discussed with each medical laboratory scientists. In addition, printed images from the challenges are presented at huddle to add microbiology knowledge. On the first three challenges, Gram staining was read correctly in 71%-77% of the time while morphology 53%-66%. In the last six challenges correct answers for Gram stain were 77%-99% while morphology 73%-96%. We observed statistically significant improvement when reading Gram stains by providing frequent challenges to medical laboratory scientists. The clinical importance of Gram stain results is emphasized during huddle presentations increasing knowledge and motivation to perform the test for patients.
Mechanical characterization of an additively manufactured Inconel 718 theta-shaped specimen
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cakmak, Ercan; Watkins, Thomas R.; Bunn, Jeffrey R.
Two sets of “theta”-shaped specimens were additively manufactured with Inconel 718 powders using an electron beam melting technique with two distinct scan strategies. Light optical microscopy, mechanical testing coupled with a digital image correlation (DIC) technique, finite element modeling, and neutron diffraction with in situ loading characterizations were conducted. The cross-members of the specimens were the focus. Light optical micrographs revealed that different microstructures were formed with different scan strategies. Ex situ mechanical testing revealed each build to be stable under load until ductility was observed on the cross-members before failure. The elastic moduli were determined by forming a correlationmore » between the elastic tensile stresses determined from FEM, and the elastic strains obtained from DIC. The lattice strains were mapped with neutron diffraction during in situ elastic loading; and a good correlation between the average axial lattice strains on the cross-member and those determined from the DIC analysis was found. Lastly, the spatially resolved stresses in the elastic deformation regime are derived from the lattice strains and increased with applied load, showing a consistent distribution along the cross-member.« less
NASA MUST Paper: Infrared Thermography of Graphite/Epoxy
NASA Technical Reports Server (NTRS)
Comeaux, Kayla; Koshti, Ajay
2010-01-01
The focus of this project is to use Infrared Thermography, a non-destructive test, to detect detrimental cracks and voids beneath the surface of materials used in the space program. This project will consist of developing a simulation model of the Infrared Thermography inspection of the Graphite/Epoxy specimen. The simulation entails finding the correct physical properties for this specimen as well as programming the model for thick voids or flat bottom holes. After the simulation is completed, an Infrared Thermography inspection of the actual specimen will be made. Upon acquiring the experimental test data, an analysis of the data for the actual experiment will occur, which includes analyzing images, graphical analysis, and analyzing numerical data received from the infrared camera. The simulation will then be corrected for any discrepancies between it and the actual experiment. The optimized simulation material property inputs can then be used for new simulation for thin voids. The comparison of the two simulations, the simulation for the thick void and the simulation for the thin void, provides a correlation between the peak contrast ratio and peak time ratio. This correlation is used in the evaluation of flash thermography data during the evaluation of delaminations.
Correlation between strength properties in standard test specimens and molded phenolic parts
NASA Technical Reports Server (NTRS)
Turner, P S; Thomason, R H
1946-01-01
This report describes an investigation of the tensile, flexural, and impact properties of 10 selected types of phenolic molding materials. The materials were studied to see in what ways and to what extent their properties satisfy some assumptions on which the theory of strength of materials is based: namely, (a) isotropy, (b) linear stress-strain relationship for small strains, and (c) homogeneity. The effect of changing the dimensions of tensile and flexural specimens and the span-depth ratio in flexural tests were studied. The strengths of molded boxes and flexural specimens cut from the boxes were compared with results of tests on standard test specimens molded from the respective materials. The nonuniformity of a material, which is indicated by the coefficient of variation, affects the results of tests made with specimens of different sizes and tests with different methods of loading. The strength values were found to depend on the relationship between size and shape of the molded specimen and size and shape of the fillers. The most significant variations observed within a diversified group of materials were found to depend on the orientation of fibrous fillers. Of secondary importance was the dependence of the variability of test results on the pieces of filler incorporated into the molding powder as well as on the size of the piece. Static breaking strength tests on boxes molded from six representative phenolic materials correlated well with falling-ball impact tests on specimens cut from molded flat sheets. Good correlation was obtained with Izod impact tests on standard test specimens prepared from the molding materials. The static breaking strengths of the boxes do not correlate with the results of tensile or flexural tests on standard specimens.
Final Report: Posttest Analysis of Omega II Optical Specimens
DOE Office of Scientific and Technical Information (OSTI.GOV)
Newlander, C D; Fisher, J H
Preliminary posttest analyses have been completed on optical specimens exposed during the Omega II test series conducted on 14 July 2006. The Omega Facility, located at the Laboratory for Laser Energetics (LLE) at the University of Rochester was used to produce X-ray environments through the interaction of intense pulsed laser radiation upon germanium-loaded silica aerogels. The optical specimen testing was supported by GH Systems through experiment design, pre- and post-test analyses, specimen acquisition, and overall technical experience. The test specimens were fabricated and characterized by Surface Optics Corporation (SOC), San Diego, CA and were simple protected gold coatings on silicamore » substrates. Six test specimens were exposed, five filtered with thin beryllium foil filters, and one unfiltered which was exposed directly to the raw environment. The experimental objectives were: (1) demonstrate that tests of optical specimens could be performed at the Omega facility; (2) evaluate the use and survivability of beryllium foil filters as a function of thickness; (3) obtain damage data on optical specimens which ranged from no damage to damage; (4) correlate existing thermal response models with the damage data; (5) evaluate the use of the direct raw environment upon the specimen response and the ability/desirability to conduct sensitive optical specimen tests using the raw environment; and (6) initiate the development of a protocol for performing optical coatings/mirror tests. This report documents the activities performed by GH Systems in evaluating and using the environments provided by LLNL, the PUFFTFT analyses performed using those environments, and the calculated results compared to the observed and measured posttest data.« less
Testing of Action of Direct Flame on Concrete
Valek, Jaroslav; Novosad, Petr
2015-01-01
The paper states results of experimental exposition of concrete test specimens to direct flame. Concrete test specimens made from various mixtures differing in the type of aggregate, binder, dispersed reinforcement, and technological procedure were subjected to thermal load. Physicomechanical and other properties of all test specimens were tested before exposition to open flame: density, compressive strength, flexural strength, moisture content, and surface appearance. The specimens were visually observed during exposition to open flame and changes were recorded. Exposed surface was photographically documented before thermal load and at 10-minute intervals. Development of temperature of the specimens was documented with a thermocamera. After exposition to thermal load and cooling down, concrete specimens were visually observed, network of cracks was photographically documented, and maximal depth of spalled area was measured. PMID:25830162
Fatigue Resistance of the Grain Size Transition Zone in a Dual Microstructure Superalloy Disk
NASA Technical Reports Server (NTRS)
Gabb, T. P.; Kantzos, P. T.; Telesman, J.; Gayda, J.; Sudbrack, C. K.; Palsa, B. S.
2010-01-01
Mechanical property requirements vary with location in nickel-based superalloy disks. To maximize the associated mechanical properties, heat treatment methods have been developed for producing tailored microstructures. In this study, a specialized heat treatment method was applied to produce varying grain microstructures from the bore to the rim portions of a powder metallurgy processed nickel-based superalloy disk. The bore of the contoured disk consisted of fine grains to maximize strength and fatigue resistance at lower temperatures. The rim microstructure of the disk consisted of coarse grains for maximum resistance to creep and dwell crack growth at high temperatures up to 704 C. However, the fatigue resistance of the grain size transition zone was unclear, and needed to be evaluated. This zone was located as a band in the disk web between the bore and rim. Specimens were extracted parallel and transverse to the transition zone, and multiple fatigue tests were performed at 427 and 704 C. Mean fatigue lives were lower at 427 C than for 704 C. Specimen failures often initiated at relatively large grains, which failed on crystallographic facets. Grain size distributions were characterized in the specimens, and related to the grains initiating failures as well as location within the transition zone. Fatigue life decreased with increasing maximum grain size. Correspondingly, mean fatigue resistance of the transition zone was slightly higher than that of the rim, but lower than that of the bore. The scatter in limited tests of replicates was comparable for all transition zone locations examined.
Strength evaluation test of pressureless-sintered silicon nitride at room temperature
NASA Technical Reports Server (NTRS)
Matsusue, K.; Takahara, K.; Hashimoto, R.
1984-01-01
In order to study strength characteristics at room temperature and the strength evaluating method of ceramic materials, the following tests were conducted on pressureless sintered silicon nitride specimens: bending tests, the three tensile tests of rectangular plates, holed plates, and notched plates, and spin tests of centrally holed disks. The relationship between the mean strength of specimens and the effective volume of specimens are examined using Weibull's theory. The effect of surface grinding on the strength of specimens is discussed.
Bingham, Andrea M; Cone, Marshall; Mock, Valerie; Heberlein-Larson, Lea; Stanek, Danielle; Blackmore, Carina; Likos, Anna
2016-05-13
In May 2015, Zika virus was reported to be circulating in Brazil. This was the first identified introduction of the virus in the Region of the Americas. Since that time, Zika virus has rapidly spread throughout the region. As of April 20, 2016, the Florida Department of Health Bureau of Public Health Laboratories (BPHL) has tested specimens from 913 persons who met state criteria for Zika virus testing. Among these 913 persons, 91 met confirmed or probable Zika virus disease case criteria and all cases were travel-associated (1). On the basis of previous small case studies reporting real time reverse-transcription polymerase chain reaction (RT-PCR) detection of Zika virus RNA in urine, saliva, and semen (2-6), the Florida Department of Health collected multiple specimen types from persons with suspected Zika virus disease. Test results were evaluated by specimen type and number of days after symptom onset to determine the most sensitive and efficient testing algorithm for acute Zika virus disease. Urine specimens were collected from 70 patients with suspected Zika virus disease from zero to 20 days after symptom onset. Of these, 65 (93%) tested positive for Zika virus RNA by RT-PCR. Results for 95% (52/55) of urine specimens collected from persons within 5 days of symptom onset tested positive by RT-PCR; only 56% (31/55) of serum specimens collected on the same date tested positive by RT-PCR. Results for 82% (9/11) of urine specimens collected >5 days after symptom onset tested positive by RT-PCR; none of the RT-PCR tests for serum specimens were positive. No cases had results that were exclusively positive by RT-PCR testing of saliva. BPHL testing results suggest urine might be the preferred specimen type to identify acute Zika virus disease.
46 CFR 54.05-5 - Toughness test specimens.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Toughness test specimens. 54.05-5 Section 54.05-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Toughness Tests § 54.05-5 Toughness test specimens. (a) Charpy V-notch impact tests. Where required, Charpy V-notch tests shall be conducted in accordanc...
The effect of image quality, repeated study, and assessment method on anatomy learning.
Fenesi, Barbara; Mackinnon, Chelsea; Cheng, Lucia; Kim, Joseph A; Wainman, Bruce C
2017-06-01
The use of two-dimensional (2D) images is consistently used to prepare anatomy students for handling real specimen. This study examined whether the quality of 2D images is a critical component in anatomy learning. The visual clarity and consistency of 2D anatomical images was systematically manipulated to produce low-quality and high-quality images of the human hand and human eye. On day 0, participants learned about each anatomical specimen from paper booklets using either low-quality or high-quality images, and then completed a comprehension test using either 2D images or three-dimensional (3D) cadaveric specimens. On day 1, participants relearned each booklet, and on day 2 participants completed a final comprehension test using either 2D images or 3D cadaveric specimens. The effect of image quality on learning varied according to anatomical content, with high-quality images having a greater effect on improving learning of hand anatomy than eye anatomy (high-quality vs. low-quality for hand anatomy P = 0.018; high-quality vs. low-quality for eye anatomy P = 0.247). Also, the benefit of high-quality images on hand anatomy learning was restricted to performance on short-answer (SA) questions immediately after learning (high-quality vs. low-quality on SA questions P = 0.018), but did not apply to performance on multiple-choice (MC) questions (high-quality vs. low-quality on MC questions P = 0.109) or after participants had an additional learning opportunity (24 hours later) with anatomy content (high vs. low on SA questions P = 0.643). This study underscores the limited impact of image quality on anatomy learning, and questions whether investment in enhancing image quality of learning aids significantly promotes knowledge development. Anat Sci Educ 10: 249-261. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.
Tanaka, M.; Nakayama, H.; Sagiyama, K.; Haraoka, M.; Yoshida, H.; Hagiwara, T.; Akazawa, K.; Naito, S.
2000-01-01
Aims—To compare the performance of a new generation dual amplified enzyme immunoassay (EIA) with a molecular method for the diagnosis of Chlamydia trachomatis, using a range of urogenital samples, and to assess the reliability of testing self collected vaginal specimens compared with clinician collected vaginal specimens. Methods—Two population groups were tested. For the first population group, first void urine samples were collected from 193 male patients with urethritis, and endocervical swabs were collected from 187 high risk commercial sex workers. All urine and endocervical specimens were tested by a conventional assay (IDEIA chlamydia), a new generation amplified immunoassay (IDEIA PCE chlamydia), and the Amplicor polymerase chain reaction (PCR). Discrepant results obtained among the three sample types were confirmed using a nested PCR test with a different plasmid target region. For the second population group, four swab specimens, including one patient obtained vaginal swab, two clinician obtained endocervical swabs, and one clinician obtained vaginal swab, were collected from 91 high risk sex workers. Self collected and clinician collected vaginal swabs were tested by IDEIA PCE chlamydia. Clinician obtained endocervical swabs were assayed by IDEIA PCE chlamydia and Amplicor PCR. Results—The performance of the IDEIA PCE chlamydia test was comparable to that of the Amplicor PCR test when male urine and female endocervical swab specimens were analysed. The relative sensitivities of IDEIA, IDEIA PCE, and Amplicor PCR on male first void urine specimens were 79.3%, 91.4%, and 100%, respectively. The relative sensitivities of the three tests on female endocervical specimens were 85.0%, 95.0%, and 100%, respectively. The positivity rates for patient collected vaginal specimens and clinician collected vaginal specimens by IDEIA PCE were 25.2% and 23.1%, respectively, whereas those for clinician collected endocervical swabs by PCR and IDEIA PCE were both 27.5%. Conclusions—IDEIA PCE chlamydia is a lower cost but sensitive alternative test to PCR for testing male urine samples and female endocervical swabs. In addition, self collected or clinician collected vaginal specimens tested by IDEIA PCE chlamydia are a reliable alternative to analysing endocervical specimens. Key Words: Chlamydia trachomatis • enzyme immunoassay • clinical specimens PMID:10889816
Lipson, S M; Leonardi, G P; Salo, R J; Schutzbank, T E; Kaplan, M H
1990-01-01
Sixty-five stool specimens obtained from children suffering from gastroenteritis were tested for the presence of antigen to rotavirus by the Abbott TestPack Rotavirus (TestPack) enzyme immunoassay kit. The Kallestad Pathfinder enzyme immunoassay, polyacrylamide gel electrophoresis, immune electron microscopy, and virus isolation were utilized as reference assays. Fifty-four specimens were in accord by TestPack and Kallestad Pathfinder. Among 11 discordant specimens positive with TestPack but negative by Kallestad Pathfinder, rotavirus was not identified by polyacrylamide gel electrophoresis, immune electron microscopy, or isolation in primary African green monkey kidney cell cultures. TestPack displayed a performance specificity of 83%. The inordinately high number of stool specimens reported as false-positive by TestPack precludes the incorporation of this antigen detection kit into our routine regimen of diagnostic virologic testing. Images PMID:2166074
A Study of the "toss Factor" in the Impact Testing of Cermets by the Izod Pendulum Test
NASA Technical Reports Server (NTRS)
Probst, H B; Mchenry, Howard T
1957-01-01
The test method presented shows that the "toss energy" contributed by the apparatus for brittle materials is negligible. The total toss energy is considered to consist of two components. (a) recovered stored elastic energy and (b) kinetic energy contributed directly by the apparatus. The results were verified by high-speed motion pictures of the test in operation. From these photographs, velocities of tossed specimens were obtained and toss energy computed. In addition, impact energies of some titanium carbide base cermets and high-temperature alloys, as measured by the low-capacity Izod pendulum test, compare well with impact energies measured by the NACA drop test.
NASA Astrophysics Data System (ADS)
Zenkov, E. V.
2018-01-01
Two methods are given in the article by considering the type of stressed-Deformed state (SDS) based on equations limit condition and analyzing the results of laboratory tests of special specimens for mechanical testing, focus having destruction thereof in the same view of SDS as in focus possible destruction of the structural member. The considered limited use of these methods in terms of considering physically consistent strength criterion type Pisarenko-Lebedev. A revised design-experimental procedure for determining the strength of the material of the structure, combining therein the elements of these two methods, consisting in determining the strength parameters of construction material, entering criterion equation Pisarenko-Lebedev, considering the actual appearance of the region-of-interest SDS structure. The implementation of the procedure is performed on the basis of the selection of the respective experimental laboratory specimens for mechanical testing, plan SDS in working zone coinciding with a SDS: structure whose strength is evaluated. The refinement process limit state equations demonstrated in determining 50CrV4 steel strength parameters, being in a state of biaxial stretching. Design-experimentally determined by, that steel for a given voltage limit value is almost a quarter of its value is reduced compared to the conventional tensile strength. value is reduced compared to the conventional tensile strength.
Spencer, Sarah; Gaglani, Manjusha; Naleway, Allison; Reynolds, Sue; Ball, Sarah; Bozeman, Sam; Henkle, Emily; Meece, Jennifer; Vandermause, Mary; Clipper, Lydia; Thompson, Mark
2013-11-01
In our prospective cohort study, we compared the performance of nasopharyngeal, oropharyngeal, and nasal swabs for the detection of influenza virus using real-time reverse transcription-PCR assay. Joint consideration of results from oropharyngeal and nasal swabs was as effective as consideration of results from nasopharyngeal swabs alone, as measured by sensitivity and noninferiority analysis.
Ye, Xuan; Cui, Zhiguo; Fang, Huajun; Li, Xide
2017-01-01
We report a novel material testing system (MTS) that uses hierarchical designs for in-situ mechanical characterization of multiscale materials. This MTS is adaptable for use in optical microscopes (OMs) and scanning electron microscopes (SEMs). The system consists of a microscale material testing module (m-MTM) and a nanoscale material testing module (n-MTM). The MTS can measure mechanical properties of materials with characteristic lengths ranging from millimeters to tens of nanometers, while load capacity can vary from several hundred micronewtons to several nanonewtons. The m-MTM is integrated using piezoelectric motors and piezoelectric stacks/tubes to form coarse and fine testing modules, with specimen length from millimeters to several micrometers, and displacement distances of 12 mm with 0.2 µm resolution for coarse level and 8 µm with 1 nm resolution for fine level. The n-MTM is fabricated using microelectromechanical system technology to form active and passive components and realizes material testing for specimen lengths ranging from several hundred micrometers to tens of nanometers. The system’s capabilities are demonstrated by in-situ OM and SEM testing of the system’s performance and mechanical properties measurements of carbon fibers and metallic microwires. In-situ multiscale deformation tests of Bacillus subtilis filaments are also presented. PMID:28777341
Code of Federal Regulations, 2010 CFR
2010-01-01
... maintained by APHIS. (a) Application for permit; reservation required. (1) For swine and swine test specimens..., number or quantity of swine or swine test specimens to be imported; the purpose of the importation... port of entry in the United States; the proposed date of arrival of the swine or swine test specimens...
Code of Federal Regulations, 2012 CFR
2012-01-01
... maintained by APHIS. (a) Application for permit; reservation required. (1) For swine and swine test specimens..., number or quantity of swine or swine test specimens to be imported; the purpose of the importation... port of entry in the United States; the proposed date of arrival of the swine or swine test specimens...
Code of Federal Regulations, 2011 CFR
2011-01-01
... maintained by APHIS. (a) Application for permit; reservation required. (1) For swine and swine test specimens..., number or quantity of swine or swine test specimens to be imported; the purpose of the importation... port of entry in the United States; the proposed date of arrival of the swine or swine test specimens...
NASA Technical Reports Server (NTRS)
Ratcliffe, James G.
2004-01-01
The edge crack torsion (ECT) test is designed to initiate mode III delamination growth in composite laminates. The test has undergone several design changes during its development. The objective of this paper was to determine the suitability of the current ECT test design a mode III fracture test. To this end, ECT tests were conducted on specimens manufactured from IM7/8552 and S2/8552 tape laminates. Three-dimensional finite element analyses were performed. The analysis results were used to calculate the distribution of mode I, mode II, and mode III strain energy release rate along the delamination front. The results indicated that mode IIIdominated delamination growth would be initiated from the specimen center. However, in specimens of both material types, the measured values of GIIIc exhibited significant dependence on delamination length. Load-displacement response of the specimens exhibited significant deviation from linearity before specimen failure. X-radiographs of a sample of specimens revealed that damage was initiated in the specimens prior to failure. Further inspection of the failure surfaces is required to identify the damage and determine that mode III delamination is initiated in the specimens.
Compaction behavior of surrogate degraded emplaced WIPP waste.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Broome, Scott Thomas; Bronowski, David R.; Kuthakun, Souvanny James
The present study results are focused on laboratory testing of surrogate waste materials. The surrogate wastes correspond to a conservative estimate of degraded Waste Isolation Pilot Plant (WIPP) containers and TRU waste materials at the end of the 10,000 year regulatory period. Testing consists of hydrostatic, triaxial, and uniaxial strain tests performed on surrogate waste recipes that were previously developed by Hansen et al. (1997). These recipes can be divided into materials that simulate 50% and 100% degraded waste by weight. The percent degradation indicates the anticipated amount of iron corrosion, as well as the decomposition of cellulosics, plastics, andmore » rubbers (CPR). Axial, lateral, and volumetric strain and axial, lateral, and pore stress measurements were made. Two unique testing techniques were developed during the course of the experimental program. The first involves the use of dilatometry to measure sample volumetric strain under a hydrostatic condition. Bulk moduli of the samples measured using this technique were consistent with those measured using more conventional methods. The second technique involved performing triaxial tests under lateral strain control. By limiting the lateral strain to zero by controlling the applied confining pressure while loading the specimen axially in compression, one can maintain a right-circular cylindrical geometry even under large deformations. This technique is preferred over standard triaxial testing methods which result in inhomogeneous deformation or (3z(Bbarreling(3y. (BManifestations of the inhomogeneous deformation included non-uniform stress states, as well as unrealistic Poissons ratios (> 0.5) or those that vary significantly along the length of the specimen. Zero lateral strain controlled tests yield a more uniform stress state, and admissible and uniform values of Poissons ratio.« less
NASA Technical Reports Server (NTRS)
Pawlik, Ralph; Krause, David; Bremenour, Frank
2011-01-01
The Force Limit System (FLS) was developed to protect test specimens from inadvertent overload. The load limit value is fully adjustable by the operator and works independently of the test system control as a mechanical (non-electrical) device. When a test specimen is loaded via an electromechanical or hydraulic test system, a chance of an overload condition exists. An overload applied to a specimen could result in irreparable damage to the specimen and/or fixturing. The FLS restricts the maximum load that an actuator can apply to a test specimen. When testing limited-run test articles or using very expensive fixtures, the use of such a device is highly recommended. Test setups typically use electronic peak protection, which can be the source of overload due to malfunctioning components or the inability to react quickly enough to load spikes. The FLS works independently of the electronic overload protection.
GenoType® Mtbdrsl assay for resistance to second-line anti-tuberculosis drugs
Theron, Grant; Peter, Jonny; Richardson, Marty; Warren, Rob; Dheda, Keertan; Steingart, Karen R
2016-01-01
Background Genotype® MTBDRsl (MTBDRsl) is a rapid DNA-based test for detecting specific mutations associated with resistance to fluoroquinolones and second-line injectable drugs (SLIDs) in Mycobacterium tuberculosis complex. MTBDRsl version 2.0 (released in 2015) identifies the mutations detected by version 1.0, as well as additional mutations. The test may be performed on a culture isolate or a patient specimen, which eliminates delays associated with culture. Version 1.0 requires a smear-positive specimen, while version 2.0 may use a smear-positive or -negative specimen. We performed this updated review as part of a World Health Organization process to develop updated guidelines for using MTBDRsl. Objectives To assess and compare the diagnostic accuracy of MTBDRsl for: 1. fluoroquinolone resistance, 2. SLID resistance, and 3. extensively drug-resistant tuberculosis, indirectly on a M. tuberculosis isolate grown from culture or directly on a patient specimen. Participants were people with rifampicin-resistant or multidrug-resistant tuberculosis. The role of MTBDRsl would be as the initial test, replacing culture-based drug susceptibility testing (DST), for detecting second-line drug resistance. Search methods We searched the following databases without language restrictions up to 21 September 2015: the Cochrane Infectious Diseases Group Specialized Register; MEDLINE; Embase OVID; Science Citation Index Expanded, Conference Proceedings Citation Index-Science, and BIOSIS Previews (all three from Web of Science); LILACS; and SCOPUS; registers for ongoing trials; and ProQuest Dissertations & Theses A&I. We reviewed references from included studies and contacted specialists in the field. Selection criteria We included cross-sectional and case-control studies that determined MTBDRsl accuracy against a defined reference standard (culture-based DST, genetic sequencing, or both). Data collection and analysis Two review authors independently extracted data and assessed quality using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. We synthesized data for versions 1.0 and 2.0 separately. We estimated MTBDRsl sensitivity and specificity for fluoroquinolone resistance, SLID resistance, and extensively drug-resistant tuberculosis when the test was performed indirectly or directly (smear-positive specimen for version 1.0, smear-positive or -negative specimen for version 2.0). We explored the influence on accuracy estimates of individual drugs within a drug class and of different reference standards. We performed most analyses using a bivariate random-effects model with culture-based DST as reference standard. Main results We included 27 studies. Twenty-six studies evaluated version 1.0, and one study version 2.0. Of 26 studies stating specimen country origin, 15 studies (58%) evaluated patients from low- or middle-income countries. Overall, we considered the studies to be of high methodological quality. However, only three studies (11%) had low risk of bias for the reference standard; these studies used World Health Organization (WHO)-recommended critical concentrations for all drugs in the culture-based DST reference standard. MTBDRsl version 1.0 Fluoroquinolone resistance: indirect testing, MTBDRsl pooled sensitivity and specificity (95% confidence interval (CI)) were 85.6% (79.2% to 90.4%) and 98.5% (95.7% to 99.5%), (19 studies, 2223 participants); direct testing (smear-positive specimen), pooled sensitivity and specificity were 86.2% (74.6% to 93.0%) and 98.6% (96.9% to 99.4%), (nine studies, 1771 participants, moderate quality evidence). SLID resistance: indirect testing, MTBDRsl pooled sensitivity and specificity were 76.5% (63.3% to 86.0%) and 99.1% (97.3% to 99.7%), (16 studies, 1921 participants); direct testing (smear-positive specimen), pooled sensitivity and specificity were 87.0% (38.1% to 98.6%) and 99.5% (93.6% to 100.0%), (eight studies, 1639 participants, low quality evidence). Extensively drug-resistant tuberculosis: indirect testing, MTBDRsl pooled sensitivity and specificity were 70.9% (42.9% to 88.8%) and 98.8% (96.1% to 99.6%), (eight studies, 880 participants); direct testing (smear-positive specimen), pooled sensitivity and specificity were 69.4% (38.8% to 89.0%) and 99.4% (95.0% to 99.3%), (six studies, 1420 participants, low quality evidence). Similar to the original Cochrane review, we found no evidence of a significant difference in MTBDRsl version 1.0 accuracy between indirect and direct testing for fluoroquinolone resistance, SLID resistance, and extensively drug-resistant tuberculosis. MTBDRsl version 2.0 Fluoroquinolone resistance: direct testing, MTBDRsl sensitivity and specificity were 97% (83% to 100%) and 98% (93% to 100%), smear-positive specimen; 80% (28% to 99%) and 100% (40% to 100%), smear-negative specimen. SLID resistance: direct testing, MTBDRsl sensitivity and specificity were 89% (72% to 98%) and 90% (84% to 95%), smear-positive specimen; 80% (28% to 99%) and 100% (40% to 100%), smear-negative specimen. Extensively drug-resistant tuberculosis: direct testing, MTBDRsl sensitivity and specificity were 79% (49% to 95%) and 97% (93% to 99%), smear-positive specimen; 50% (1% to 99%) and 100% (59% to 100%), smear-negative specimen. We had insufficient data to estimate summary sensitivity and specificity of version 2.0 (smear-positive and -negative specimens) or to compare accuracy of the two versions. A limitation was that most included studies did not consistently use the World Health Organization (WHO)-recommended concentrations for drugs in the culture-based DST reference standard. Authors' conclusions In people with rifampicin-resistant or multidrug-resistant tuberculosis, MTBDRsl performed on a culture isolate or smear-positive specimen may be useful in detecting second-line drug resistance. MTBDRsl (smear-positive specimen) correctly classified around six in seven people as having fluoroquinolone or SLID resistance, although the sensitivity estimates for SLID resistance varied. The test rarely gave a positive result for people without drug resistance. However, when second-line drug resistance is not detected (MTBDRsl result is negative), conventional DST can still be used to evaluate patients for resistance to the fluoroquinolones or SLIDs. We recommend that future work evaluate MTBDRsl version 2.0, in particular on smear-negative specimens and in different settings to account for different resistance-causing mutations that may vary by strain. Researchers should also consider incorporating WHO-recommended critical concentrations into their culture-based reference standards. PLAIN LANGUAGE SUMMARY The rapid test GenoType® MTBDRsl for testing resistance to second-line TB drugs Background Different drugs are available to treat tuberculosis (TB), but resistance to these drugs is a growing problem. People with drug-resistant TB require second-line TB drugs that, compared with first-line TB drugs, must be taken for longer and may be associated with more harms. Detecting TB drug resistance quickly is important for improving health, reducing deaths, and decreasing the spread of drug-resistant TB. Definitions Multidrug-resistant TB (MDR-TB) is caused by TB bacteria that are resistant to at least isoniazid and rifampicin, the two most potent TB drugs. Extensively drug-resistant TB (XDR-TB) is a type of MDR-TB that is resistant to nearly all TB drugs. What test is evaluated by this review? GenoType® MTBDRsl (MTBDRsl) is a rapid test for detecting resistance to second-line TB drugs. In people with MDR-TB, MTBDRsl is used to detect additional drug resistance. The test may be performed on TB bacteria grown in culture from a patient specimen (indirect testing) or on a patient specimen (direct testing), which eliminates delays associated with culture. MTBDRsl version 1.0 requires a specimen to be smear-positive by microscopy, while version 2.0 (released in 2015) may use a smear-positive or -negative specimen. What are the aims of the review? We wanted to find out how accurate MTBDRsl is for detecting drug resistance; to compare indirect and direct testing; and to compare the two test versions. How up-to-date is the review? We searched for and used studies that had been published up to 21 September 2015. What are the main results of the review? We found 27 studies; 26 studies evaluated MTBDRsl version 1.0 and one study evaluated version 2.0. Fluoroquinolone drugs MTBDRsl version 1.0 (smear-positive specimen) detected 86% of people with fluoroquinolone resistance and rarely gave a positive result for people without resistance (GRADE, moderate quality evidence). Second-line injectable drugs MTBDRsl version 1.0 (smear-positive specimen) detected 87% of people with second-line injectable drug resistance and rarely gave a positive result for people without resistance (GRADE, low quality evidence). XDR-TB MTBDRsl version 1.0 (smear-positive specimen) detected 69% of people with XDR-TB and rarely gave a positive result for people without resistance (GRADE, low quality evidence). For MTBDRsl version 1.0, we found similar results for indirect and direct testing (smear-positive specimen). As we identified only one study evaluating MTBDRsl version 2.0, we could not be sure of the diagnostic accuracy of version 2.0. Also, we could not compare accuracy of the two versions. What is the methodological quality of the evidence? We used the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool to assess study quality. Overall, we considered the included studies to be of high quality; however, we had concerns about how the reference standard (the benchmark against which MTBDRsl was measured) was applied. What are the authors' conclusions? MTBDRsl (smear-positive specimen) identified most of the patients with second-line drug resistance. When the test reports a negative result, conventional testing for drug resistance can still be used. PMID:27605387
Comparison of five assays for detection of Clostridium difficile toxin.
Chapin, Kimberle C; Dickenson, Roberta A; Wu, Fongman; Andrea, Sarah B
2011-07-01
Performance characteristics of five assays for detection of Clostridium difficile toxin were compared using fresh stool samples from patients with C. difficile infection (CDI). Assays were performed simultaneously and according to the manufacturers' instructions. Patients were included in the study if they exhibited clinical symptoms consistent with CDI. Nonmolecular assays included glutamate dehydrogenase antigen tests, with positive findings followed by the Premier Toxin A and B Enzyme Immunoassay (GDH/EIA), and the C. Diff Quik Chek Complete test. Molecular assays (PCR) included the BD GeneOhm Cdiff Assay, the Xpert C. difficile test, and the ProGastro Cd assay. Specimens were considered true positive if results were positive in two or more assays. For each method, the Youden index was calculated and cost-effectiveness was analyzed. Of 81 patients evaluated, 26 (32.1%) were positive for CDI. Sensitivity of the BD GeneOhm Cdiff assay, the Xpert C. difficile test, the ProGastro Cd assay, C. Diff Quik Chek Complete test, and two-step GDH/EIA was 96.2%, 96.2%, 88.5%, 61.5%, and 42.3%, respectively. Specificity of the Xpert C. difficile test was 96.4%, and for the other four assays was 100%. Compared with nonmolecular methods, molecular methods detected 34.7% more positive specimens. Assessment of performance characteristics and cost-effectiveness demonstrated that the BD GeneOhm Cdiff assay yielded the best results. While costly, the Xpert C. difficile test required limited processing and yielded rapid results. Because of discordant results, specimen processing, and extraction equipment requirements, the ProGastro Cd assay was the least favored molecular assay. The GDH/EIA method lacked sufficient sensitivity to be recommended. Copyright © 2011 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Comparison of Five Assays for Detection of Clostridium difficile Toxin
Chapin, Kimberle C.; Dickenson, Roberta A.; Wu, Fongman; Andrea, Sarah B.
2011-01-01
Performance characteristics of five assays for detection of Clostridium difficile toxin were compared using fresh stool samples from patients with C. difficile infection (CDI). Assays were performed simultaneously and according to the manufacturers' instructions. Patients were included in the study if they exhibited clinical symptoms consistent with CDI. Nonmolecular assays included glutamate dehydrogenase antigen tests, with positive findings followed by the Premier Toxin A and B Enzyme Immunoassay (GDH/EIA), and the C. Diff Quik Chek Complete test. Molecular assays (PCR) included the BD GeneOhm Cdiff Assay, the Xpert C. difficile test, and the ProGastro Cd assay. Specimens were considered true positive if results were positive in two or more assays. For each method, the Youden index was calculated and cost-effectiveness was analyzed. Of 81 patients evaluated, 26 (32.1%) were positive for CDI. Sensitivity of the BD GeneOhm Cdiff assay, the Xpert C. difficile test, the ProGastro Cd assay, C. Diff Quik Chek Complete test, and two-step GDH/EIA was 96.2%, 96.2%, 88.5%, 61.5%, and 42.3%, respectively. Specificity of the Xpert C. difficile test was 96.4%, and for the other four assays was 100%. Compared with nonmolecular methods, molecular methods detected 34.7% more positive specimens. Assessment of performance characteristics and cost-effectiveness demonstrated that the BD GeneOhm Cdiff assay yielded the best results. While costly, the Xpert C. difficile test required limited processing and yielded rapid results. Because of discordant results, specimen processing, and extraction equipment requirements, the ProGastro Cd assay was the least favored molecular assay. The GDH/EIA method lacked sufficient sensitivity to be recommended. PMID:21704273
Oki, Masahide; Yatabe, Yasushi; Saka, Hideo; Kitagawa, Chiyoe; Kogure, Yoshihito; Ichihara, Shu; Moritani, Suzuko
2015-01-01
During bronchoscopy, small biopsy forceps are increasingly used for the diagnosis of peripheral pulmonary lesions. However, it is unclear whether the formalin-fixed paraffin-embedded specimens sampled with the small biopsy forceps are suitable for the determination of genotypes which become indispensable for the management decision regarding patients with non-small cell lung cancer. The aim of this study was to evaluate the feasibility and accuracy of molecular testing in the specimens obtained with 1.5-mm small biopsy forceps. We examined specimens in 91 patients, who were enrolled in our previous 3 studies on the usefulness of thin bronchoscopes and given a diagnosis of non-small cell lung cancer by bronchoscopy with the 1.5-mm biopsy forceps, and then underwent surgical resection. An experienced pathologist examined paraffin-embedded specimens obtained by bronchoscopic biopsy or surgical resection in a blind fashion on epidermal growth factor receptor (EGFR) mutations, anaplastic lymphoma kinase (ALK) rearrangements and KRAS mutations. Twenty-five (27%), 2 (2%) and 5 (5%) patients had an EGFR mutation, ALK rearrangement and KRAS mutation, respectively, based on the results in surgical specimens. EGFR, ALK and KRAS testing with bronchoscopic specimens was feasible in 82 (90%), 86 (95%) and 83 (91%) patients, respectively. If molecular testing was feasible, the accuracy of EGFR, ALK and KRAS testing with bronchoscopic specimens for the results with surgical specimens was 98, 100 and 98%, respectively. The results of molecular testing in the formalin-fixed paraffin-embedded specimens obtained with the small forceps, in which the genotype could be evaluated, correlated well with those in surgically resected specimens.
Manlutac, Anna Liza M; Giesick, Jill S; McVay, Patricia A
2013-12-01
HIV screening assays have gone through several generations of development in an effort to narrow the "window period" of detection. Utilizing a fourth generation HIV screening assay has the potential to detect earlier HIV infection, thus reducing HIV-1 transmission. To identify acute infections to decrease HIV transmission in San Diego County. Serum specimens were collected from clients seen by multiple submitters in San Diego County. All acceptable specimens were screened using the 4th Gen Combo Assay. Initially reactive specimens were repeated in duplicate and if repeatedly reactive, were confirmed by HIV-1 Immunofluorescent Antibody Assay (IFA). IFA negative/inconclusive specimens were sent for HIV-1 NAT and HIV-2 antibody testing to referral laboratories. BioRad Multispot HIV-1/HIV-2 Rapid Test was also performed on a subset of specimens. Of 14,559 specimens received in 20 months, 14,517 specimens were tested. Of the 14,517 specimens that were tested, a total of 279 (1.9%) specimens were CIA repeatedly reactive and 240 of the 279 confirmed by HIV-1 IFA. Thirty-nine gave IFA negative/inconclusive result and 30 were further tested for HIV-1 NAT and 36 for HIV-2 antibody. Thirteen specimens were considered false positives by CIA and 17 specimens were classified as acute infections. Eleven of 39 IFA negative/inconclusive specimens were further tested by Multispot. Five of the 11 were positive by Multispot. The fourth generation Abbott ARCHITECT HIV Ag/Ab Combo Assay identified 17 patients who may have been missed by the prior HIV-1 screening assay used at San Diego County Public Health Laboratory. Copyright © 2013 Elsevier B.V. All rights reserved.
Tension fracture of laminates for transport fuselage. Part 1: Material screening
NASA Technical Reports Server (NTRS)
Walker, T. H.; Avery, W. B.; Ilcewicz, L. B.; Poe, C. C., Jr.; Harris, C. E.
1992-01-01
Transport fuselage structures are designed to contain pressure following a large penetrating damage event. Applications of composites to fuselage structures require a database and supporting analysis on tension damage tolerance. Tests with 430 fracture specimens were used to accomplish the following: (1) identify critical material and laminate variables affecting notch sensitivity; (2) evaluate composite failure criteria; and (3) recommend a screening test method. Variables studied included fiber type, matrix toughness, lamination manufacturing process, and intraply hybridization. The laminates found to have the lowest notch sensitivity were manufactured using automated tow placement. This suggests a possible relationship between the stress distribution and repeatable levels of material inhomogeneity that are larger than found in traditional tape laminates. Laminates with the highest notch sensitivity consisted of toughened matrix materials that were resistant to a splitting phenomena that reduces stress concentrations in major load bearing plies. Parameters for conventional fracture criteria were found to increase with crack length for the smallest notch sizes studied. Most material and laminate combinations followed less than a square root singularity for the largest crack sizes studied. Specimen geometry, notch type, and notch size were evaluated in developing a screening test procedure. Traitional methods of correcting for specimen finite width were found to be lacking. Results indicate that a range of notch sizes must be tested to determine notch sensitivity. Data for a single small notch size (0.25 in. diameter) was found to give no indication of the sensitivity of a particular material and laminate layup to larger notch sizes.
NASA Technical Reports Server (NTRS)
Nettles, A. T.; Hodge, A. J.
1997-01-01
Low velocity dropweight impact tests were conducted on carbon/epoxy laminates under various boundary conditions. The composite plates were 8-ply (+45,0,-45,90)s laminates supported in a clamped-clamped/free-free configuration with varying amounts of in-plane load, N(sub x), applied. Specimens were impacted at energies of 3.4, 4.5, and 6 Joules (2.5, 3.3, and 4.4 ft-lb). The amount of damage induced into the specimen was evaluated using instrumented impact techniques, x-ray inspection, and cross-sectional photomicroscopy. Some static identation tests were performed to examine if the impact events utilized in this study were of a quasi-static nature and also to gain insight into the shape of the deflected surface at various impact load combinations. Load-displacement curves from these tests were compared to those of the impact tests, as was damage determined from x-ray inspection. The finite element technique was used to model the impact event and determine the stress field within the laminae. Results showed that for a given impact energy level, more damage was induced into the specimen as the external in-plane load, N(sub x), was increased. The majority of damage observed consisted of back face splitting of the matrix parallel to the fibers in that ply, associated with delaminations emanating from these splits. The analysis showed qualitatively the results of impact conditions on maximum load of impact, maximum transverse deflection, and first failure mode and location.
10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.
Code of Federal Regulations, 2011 CFR
2011-01-01
... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...
10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.
Code of Federal Regulations, 2010 CFR
2010-01-01
... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...
10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.
Code of Federal Regulations, 2014 CFR
2014-01-01
... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...
10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.
Code of Federal Regulations, 2012 CFR
2012-01-01
... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...
10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.
Code of Federal Regulations, 2013 CFR
2013-01-01
... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...
Confined Tension and Triaxial Extension Tests on Eglin High-Strength Concrete
2014-10-17
specimen were filled with Devcon 5-Minute epoxy . We encased the specimen in a liquid-tight flexible jacket to exclude the confining fluid from any...sealed to the steel endcaps with epoxy and wire clamps. Figure 3. Schematic diagram of test specimen prepared for TXE testing. TXE tests are...150 MPa – we wrapped two Kevlar jackets (0.01 in thick) around the specimen prior to installing the polyolefin jacket (0.02 in thick). The Kevlar
Biaxial and Shear Testing Apparatus with Force Controls
2006-03-30
materials as the test specimen. (2) Description of the Prior Art [0004] It is known in the art that pressurized fabric tubes ; pressure-stabilized beams...apparatus is that these roller pins prevent any torsional load from reaching the test specimen. [0010] In Ward et al., (United States Patent No. 5,279,166...loading a specimen through pressurizing the inside surface of a cylinder is disclosed. A thin-wall tube specimen is biaxially tested for stress analysis
40 CFR 160.195 - Retention of records.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., terminated, or discontinued. (c) Wet specimens, samples of test, control, or reference substances, and... storage, shall be retained only as long as the quality of the preparation affords evaluation. Specimens obtained from mutagenicity tests, specimens of soil, water, and plants, and wet specimens of blood, urine...
NASA Astrophysics Data System (ADS)
Nazzal, Mohammad; Abu-Farha, Fadi; Curtis, Richard
2011-08-01
Characterizing the behavior of superplastic materials is largely based on the uniaxial tensile test; yet the unique nature of these materials requires a particularly tailored testing methodology, different to that used with conventional materials. One of the crucial testing facets is the specimen geometry, which has a great impact on the outcome of a superplastic tensile test, as a result of the associated extreme conditions. And while researchers agree that it should take a notably different form than the typical dog-bone shape; there is no universal agreement on the specimen's particular size and dimensions, as evident by the disparities in test specimens used in the various superplastic testing efforts found throughout the literature. In view of that, this article is dedicated to understanding the effects of specimen geometry on the superplastic behavior of the material during tensile testing. Deformation of the Ti6Al4V titanium alloy is FE simulated based on a multitude of specimen geometries, covering a wide range of gauge length, gauge width, grip length, and grip width values. The study provides key insights on the influences of each geometrical parameter as well as their interactions, and provides recommendations on selecting the specimen's proportions for accurate and unified tensile testing of superplastic materials.
Strength characteristics of lightly solidified dredged marine clay admixed with bentonite
NASA Astrophysics Data System (ADS)
Ariffin, Syazwana Tajul; Chan, Chee-Ming
2017-11-01
Strength characteristic is a significant parameter in measuring the effect of soil improvement and effective composition of solidification. In this study, the dredged marine sediment (DMS) collected from Kuala Perlis (Malaysia) was examined to determine its strength characteristics under light cement solidification with bentonite. Dredged marine clay generally has the low shear strength and high void ratio, and consists mainly of soil particles of the fine-grained type. As a discarded geo-waste, it can be potentially treated to for reuse as a backfill material instead of being disposed of, hence reducing the negative impact on the environment. Physico-chemical parameters of the dredged sample were first determined, then solidification was carried out to improve the engineering properties by admixing ordinary Portland cement (OPC) as the binder and bentonite as a volume enhancer to the soil. The DMS was treated with the addition of 3 % and 6 % cement and bentonite within the range of 0-30 %. The specimens were cured at room temperature for 3, 7 and 14 days. The strength gain was measured by unconfined compression test and vane shear test. The laboratory test results were analyzed to establish the relationship between strength properties and solidification specifications. In summary, the strength of specimens increased with the increase of the quantity of bentonite and cement to get the effective composition of the specimen.
NASA Technical Reports Server (NTRS)
Vroman, G. A.
1975-01-01
The capability of shallow-notched, round-bar, tensile specimens for screening critical environments as they affect the material fracture properties of the space shuttle main engine was tested and analyzed. Specimens containing a 0.050-inch-deep circumferential sharp notch were cyclically loaded in a 5000-psi hydrogen environment at temperatures of +70 and -15 F. Replication of test results and a marked change in cyclic life because of temperature variation demonstrated the validity of the specimen type to be utilized for screening tests.
Apparatus for photon activation positron annihilation analysis
Akers, Douglas W [Idaho Falls, ID
2007-06-12
Non-destructive testing apparatus according to one embodiment of the invention comprises a photon source. The photon source produces photons having predetermined energies and directs the photons toward a specimen being tested. The photons from the photon source result in the creation of positrons within the specimen being tested. A detector positioned adjacent the specimen being tested detects gamma rays produced by annihilation of positrons with electrons. A data processing system operatively associated with the detector produces output data indicative of a lattice characteristic of the specimen being tested.
Ten deg off-axis tensile test for intralaminar shear characterization of fiber composites
NASA Technical Reports Server (NTRS)
Chamis, C. C.; Sinclair, J. H.
1976-01-01
A combined theoretical and experimental investigation was conducted to assess the suitability of the 10 deg off-axis tensile test specimen for the intralaminar shear characterization of unidirectional composites. Composite mechanics, a combined-stress failure criterion, and a finite element analysis were used to determine theoretically the stress-strain variation across the specimen width and the relative stress and strain magnitudes at the 10 deg plane. Strain gages were used to measure the strain variation across the specimen width at specimen midlength and near the end tabs. Specimens from Mod-I/epoxy, T-300/epoxy, and S-glass/epoxy were used in the experimental program. It was found that the 10 deg off-axis tensile test specimen is suitable for intralaminar shear characterization and it is recommended that it should be considered as a possible standard test specimen for such a characterization.
Controlled shear/tension fixture
Hsueh, Chun-Hway [Knoxville, TN; Liu, Chain-tsuan [Knoxville, TN; George, Easo P [Knoxville, TN
2012-07-24
A test fixture for simultaneously testing two material test samples is provided. The fixture provides substantially equal shear and tensile stresses in each test specimens. By gradually applying a load force to the fixture only one of the two specimens fractures. Upon fracture of the one specimen, the fixture and the load train lose contact and the second specimen is preserved in a state of upset just prior to fracture. Particular advantages of the fixture are (1) to control the tensile to shear load on the specimen for understanding the effect of these stresses on the deformation behavior of advanced materials, (2) to control the location of fracture for accessing localized material properties including the variation of the mechanical properties and residual stresses across the thickness of advanced materials, (3) to yield a fractured specimen for strength measurement and an unfractured specimen for examining the microstructure just prior to fracture.
Rogers, Kimberly B; Roohi, Shahrokh; Uyeki, Timothy M; Montgomery, David; Parker, Jayme; Fowler, Nisha H; Xu, Xiyan; Ingram, Deandra J; Fearey, Donna; Williams, Steve M; Tarling, Grant; Brown, Clive M; Cohen, Nicole J
2017-09-01
Influenza outbreaks can occur among passengers and crews during the Alaska summertime cruise season. Ill travellers represent a potential source for introduction of novel or antigenically drifted influenza virus strains to the United States. From May to September 2013-2015, the Alaska Division of Public Health, the Centers for Disease Control and Prevention (CDC), and two cruise lines implemented a laboratory-based public health surveillance project to detect influenza and other respiratory viruses among ill crew members and passengers on select cruise ships in Alaska. Cruise ship medical staff collected 2-3 nasopharyngeal swab specimens per week from passengers and crew members presenting to the ship infirmary with acute respiratory illness (ARI). Specimens were tested for respiratory viruses at the Alaska State Virology Laboratory (ASVL); a subset of specimens positive for influenza virus were sent to CDC for further antigenic characterization. Of 410 nasopharyngeal specimens, 83% tested positive for at least one respiratory virus; 71% tested positive for influenza A or B virus. Antigenic characterization of pilot project specimens identified strains matching predominant circulating seasonal influenza virus strains, which were included in the northern or southern hemisphere influenza vaccines during those years. Results were relatively consistent across age groups, recent travel history, and influenza vaccination status. Onset dates of illness relative to date of boarding differed between northbound (occurring later in the voyage) and southbound (occurring within the first days of the voyage) cruises. The high yield of positive results indicated that influenza was common among passengers and crews sampled with ARI. This finding reinforces the need to bolster influenza prevention and control activities on cruise ships. Laboratory-based influenza surveillance on cruise ships may augment inland influenza surveillance and inform control activities. However, these benefits should be weighed against the costs and operational limitations of instituting laboratory-based surveillance programs on ships. Published by Oxford University Press 2017. This work is written by [a] US Government employee[s] and is in the public domain in the US.
NASA Astrophysics Data System (ADS)
Tan, Eugene Wie Loon
1999-09-01
The present investigation was focussed on the mechanical characterization and structural analysis of resin-transfer-molded beams containing recycled fiber-reinforced polymers. The beams were structurally reinforced with continuous unidirectional glass fibers. The reinforcing filler materials consisted entirely of recycled fiber-reinforced polymer wastes (trim and overspray). The principal resin was a 100-percent dicyclo-pentadiene unsaturated polyester specially formulated with very low viscosity for resin transfer molding. Variations of the resin transfer molding technique were employed to produce specimens for material characterization. The basic materials that constituted the structural beams, continuous-glass-fiber-reinforced, recycled-trim-filled and recycled-overspray-filled unsaturated polyesters, were fully characterized in axial and transverse compression and tension, and inplane and interlaminar shear, to ascertain their strengths, ultimate strains, elastic moduli and Poisson's ratios. Experimentally determined mechanical properties of the recycled-trim-filled and recycled-overspray-filled materials from the present investigation were superior to those of unsaturated polyester polymer concretes and Portland cement concretes. Mechanical testing and finite element analyses of flexure (1 x 1 x 20 in) and beam (2 x 4 x 40 in) specimens were conducted. These structurally-reinforced specimens were tested and analyzed in four-point, third-point flexure to determine their ultimate loads, maximum fiber stresses and mid-span deflections. The experimentally determined load capacities of these specimens were compared to those of equivalent steel-reinforced Portland cement concrete beams computed using reinforced concrete theory. Mechanics of materials beam theory was utilized to predict the ultimate loads and mid-span deflections of the flexure and beam specimens. However, these predictions proved to be severely inadequate. Finite element (fracture propagation) analyses of the flexure and beam specimens were also performed. These progressive failure analyses more closely approximated flexural behavior under actual testing conditions by reducing the elastic moduli of elements that were considered to have partially or totally failed. Individual element failures were predicted using the maximum stress, Tsai-Hill and Tsai-Wu failure criteria. Excellent predictions of flexural behavior were attributed to the progressive failure analyses combined with an appropriate failure criterion, and the reliable input material properties that were generated.
NASA Technical Reports Server (NTRS)
Bubsey, R. T.; Pierce, W. S.; Shannon, J. L., Jr.; Munz, D.
1982-01-01
The short rod chevron-notch specimen has the advantages of (1) crack development at the chevron tip during the early stage of test loading, and (2) convenient calculation of plane-strain fracture toughness from the maximum test load and from a calibration factor which depends only on the specimen geometry and manner of loading. For generalized application, calibration of the specimen over a range of specimen proportions and chevron-notch configurations is necessary. Such was the objective of this investigation, wherein calibration of the short rod specimen was made by means of experimental compliance measurements converted into dimensionless stress intensity factor coefficients.
High temperature electromagnetic characterization of thermal protection system tile materials
NASA Technical Reports Server (NTRS)
Heil, Garrett G.
1993-01-01
This study investigated the impact of elevated temperatures on the electromagnetic performance of the LI-2200 thermal protection system. A 15-kilowatt CO2 laser was used to heat an LI-2200 specimen to 3000 F while electromagnetic measurements were performed over the frequency range of l9 to 21 GHz. The electromagnetic measurement system consisted of two Dual-Lens Spot-Focusing (DLSF) antennas, a sample support structure, and an HP-8510B vector network analyzer. Calibration of the electromagnetic system was accomplished with a Transmission-Reflection-Line (TRL) procedure and was verified with measurements on a two-layer specimen of known properties. The results of testing indicated that the LI-2200 system's electromagnetic performance is slightly temperature dependent at temperatures up to 3000 F.
A new journal bearing tester: The VTT water tribotester
NASA Astrophysics Data System (ADS)
Andersson, Peter
1992-08-01
The design and operation of equipment for the testing of journal bearings is described. The equipment was developed and used for the first time in a Finnish project in ceramic journal bearings. Two similar units were built in two different laboratories, one for oil and the other for water lubrication. The VIT (Technical Research Center of Finland) tribotester was designed for wide flexibility in the selection of the normal force, speed and lubricant and to make rapid test piece exchanges possible. Furthermore, the machine was designed to be easy to build, use, maintain and understand. The journal bearing to be tested has an inner diameter of 40 mm and a width of 20 mm. Exchangeable shaft bushes are used as counterpieces in the tests. The tribotester is designed for normal loads of up to 40 kN, and rotational speeds of up to 5300 rpm can be allowed. During the tests, at least the frictional force and the bearing shell temperature are continuously recorded. The wear rates are determined after a test. The first test program consisted of 22 water lubricated tests, 16 of which were performed with specimens made of monolithic ceramics and 6 with steel specimens plasma coated with ceramics. The results of the journal bearing tests are in good agreement with previous 'pin on disc' model tests. In the majority of the tests the equipment behaved as planned, and new investigations will follow.
49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?
Code of Federal Regulations, 2014 CFR
2014-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...
49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?
Code of Federal Regulations, 2010 CFR
2010-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...
49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?
Code of Federal Regulations, 2012 CFR
2012-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...
49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?
Code of Federal Regulations, 2011 CFR
2011-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...
49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?
Code of Federal Regulations, 2013 CFR
2013-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...
NASA Technical Reports Server (NTRS)
Sprowls, D. O.; Shumaker, M. B.; Walsh, J. D.; Coursen, J. W.
1973-01-01
Stress corrosion cracking (SSC) tests were performed on 13 aluminum alloys, 13 precipitation hardening stainless steels, and two titanium 6Al-4V alloy forgings to compare fracture mechanics techniques with the conventional smooth specimen procedures. Commercially fabricated plate and rolled or forged bars 2 to 2.5-in. thick were tested. Exposures were conducted outdoors in a seacoast atmosphere and in an inland industrial atmosphere to relate the accelerated tests with service type environments. With the fracture mechanics technique tests were made chiefly on bolt loaded fatigue precracked compact tension specimens of the type used for plane-strain fracture toughness tests. Additional tests of the aluminum alloy were performed on ring loaded compact tension specimens and on bolt loaded double cantilever beams. For the smooth specimen procedure 0.125-in. dia. tensile specimens were loaded axially in constant deformation type frames. For both aluminum and steel alloys comparative SCC growth rates obtained from tests of precracked specimens provide an additional useful characterization of the SCC behavior of an alloy.
Analysis of the stress state in an Iosipescu sheartest specimen
NASA Technical Reports Server (NTRS)
Walrath, D. E.; Adams, D. F.
1983-01-01
The state of stress in an Iosipescu shear test specimen is analyzed, utilizing a finite element computer program. The influence of test fixture configuration on this stress state is included. Variations of the standard specimen configuration, including notch depth, notch angle, and notch root radius are modeled. The purpose is to establish guidelines for a specimen geometry which will accommodate highly orthotropic materials while minimizing stress distribution nonuniformities. Materials ranging from isotropic to highly orthotropic are considered. An optimum specimen configuration is suggested, along with changes in the test fixture.
NASA Technical Reports Server (NTRS)
Ratcliffe, James G.
2010-01-01
This paper details part of an effort focused on the development of a standardized facesheet/core peel debonding test procedure. The purpose of the test is to characterize facesheet/core peel in sandwich structure, accomplished through the measurement of the critical strain energy release rate associated with the debonding process. The specific test method selected for the standardized test procedure utilizes a single cantilever beam (SCB) specimen configuration. The objective of the current work is to develop a method for establishing SCB specimen dimensions. This is achieved by imposing specific limitations on specimen dimensions, with the objectives of promoting a linear elastic specimen response, and simplifying the data reduction method required for computing the critical strain energy release rate associated with debonding. The sizing method is also designed to be suitable for incorporation into a standardized test protocol. Preliminary application of the resulting sizing method yields practical specimen dimensions.
A Size Effect on the Fatigue Crack Growth Rate Threshold of Alloy 718
NASA Technical Reports Server (NTRS)
Garr, K. R.; Hresko, G. C., III
1998-01-01
Fatigue crack growth rate (FCGR) tests were conducted on Alloy 718 in the solution annealed and aged condition at room temperature. In each test, the FCGR threshold was measured using the decreasing (Delta)K method. Initial testing was at two facilities, one of which used C(T) specimens with W = 127 mm. Previous data at the other facility had been obtained with specimens with W = 50.8 mm. A comparison of test results at R = 0.1 showed that the threshold for the 127 mm specimen was considerably higher than that of the 50.8 mm specimen. A check showed that this difference was not due to a heat-to-heat or lab-to-lab variation. Additional tests were conducted on specimens with W = 25.4 mm and at other R values. Data for the various specimens is presented along with parameters usually used to describe threshold behavior.
NASA Technical Reports Server (NTRS)
Tecza, J. A.; Darlow, M. S.; Smalley, A. J.
1979-01-01
Tests were performed on elastomer specimens of the material polybutadiene to determine the performance limitations imposed by strain, temperature, and frequency. Three specimens were tested: a shear specimen, a compression specimen, and a second compression specimen in which thermocouples were embedded in the elastomer buttons. Stiffness and damping were determined from all tests, and internal temperatures were recorded for the instrumented compression specimen. Measured results are presented together with comparisons between predictions of a thermo-viscoelastic analysis and the measured results. Dampers of polybutadiene and Viton were designed, built, and tested. Vibration measurements were made and sensitivity of vibration to change in unbalance was also determined. Values for log decrement were extracted from the synchronous response curves. Comparisons were made between measured sensitivity to unbalance and log decrement and predicted values for these quantities.
Demonstration of Advanced C/SiC Cooled Ramp
NASA Technical Reports Server (NTRS)
Bouquet, Clement; Laithier, Frederic; Lawrence, Timothy; Eckel, Andrew; Munafo, Paul M. (Technical Monitor)
2002-01-01
Under a NASA contract, SPS is evaluating its C/SiC to metal brazing technique for the development of light, composite, actively cooled panels. The program first consisted of defining a system applicable to the X-33 nozzle ramp. SPS then performed evaluation tests for tube, composite, and braze material selection, and for the adaptation of braze process parameters to the parts geometry. SPS is presently manufacturing a 250x60 millimeter squared specimen, including 10 metallic tubes, which will be cycled in the NASA/GRC-CELL-22 test bed under engine representative conditions.
Besser, Thomas E.; Cassirer, E. Frances; Potter, Kathleen A.; VanderSchalie, John; Fischer, Allison; Knowles, Donald P.; Herndon, David R.; Rurangirwa, Fred R.; Weiser, Glen C.; Srikumaran, Subramaniam
2008-01-01
Bronchopneumonia is a population-limiting disease in bighorn sheep in much of western North America. Previous investigators have isolated diverse bacteria from the lungs of affected sheep, but no single bacterial species is consistently present, even within single epizootics. We obtained high-quality diagnostic specimens from nine pneumonic bighorn sheep in three populations and analyzed the bacterial populations present in bronchoalveolar lavage specimens of seven by using a culture-independent method (16S rRNA gene amplification and clone library analyses). Mycoplasma ovipneumoniae was detected as a predominant member of the pneumonic lung flora in lambs with early lesions of bronchopneumonia. Specific PCR tests then revealed the consistent presence of M. ovipneumoniae in the lungs of pneumonic bighorn sheep in this study, and M. ovipneumoniae was isolated from lung specimens of five of the animals. Retrospective application of M. ovipneumoniae PCR to DNA extracted from archived formalin-fixed, paraffin-embedded lung tissues of historical adult bighorn sheep necropsy specimens supported the association of this agent with bronchopneumonia (16/34 pneumonic versus 0/17 nonpneumonic sheep were PCR positive [P < 0.001]). Similarly, a very strong association was observed between the presence of one or more M. ovipneumoniae antibody-positive animals and the occurrence of current or recent historical bronchopneumonia problems (seropositive animals detected in 9/9 versus 0/9 pneumonic and nonpneumonic populations, respectively [P < 0.001]). M. ovipneumoniae is strongly associated with bronchopneumonia in free-ranging bighorn sheep and is a candidate primary etiologic agent for this disease. PMID:18057131
Diagnosis of AIDS-Related Intestinal Parasites
1990-06-20
previously in ELISA tests to detect antigens of either Giardia lamblia or Entamoeba histolytica in human fecal specimens (67,68), the mean optical...techniques. Eight other intestinal parasites were idtritified Giardia lamblia (67 specimens), Endoimax nana (38 specimens), Entamoeba coli (34 specimens...tests to detect antigens of Entamoeba histolytica or Giardia lamblia in fecal specimens are now truly well-established and have been developed by at
10 CFR 26.135 - Split specimens.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Split specimens. 26.135 Section 26.135 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.135 Split specimens. (a) If the FFD program follows split-specimen procedures, as described in § 26.113, the licensee testing...
10 CFR 26.135 - Split specimens.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Split specimens. 26.135 Section 26.135 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.135 Split specimens. (a) If the FFD program follows split-specimen procedures, as described in § 26.113, the licensee testing...
10 CFR 26.135 - Split specimens.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Split specimens. 26.135 Section 26.135 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.135 Split specimens. (a) If the FFD program follows split-specimen procedures, as described in § 26.113, the licensee testing...
10 CFR 26.135 - Split specimens.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Split specimens. 26.135 Section 26.135 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.135 Split specimens. (a) If the FFD program follows split-specimen procedures, as described in § 26.113, the licensee testing...
10 CFR 26.135 - Split specimens.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Split specimens. 26.135 Section 26.135 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.135 Split specimens. (a) If the FFD program follows split-specimen procedures, as described in § 26.113, the licensee testing...
NASA Technical Reports Server (NTRS)
Lundquist, Eugene E; Schwartz, Edward B
1942-01-01
The results of a theoretical and experimental investigation to determine the critical compression load for a universal testing machine are presented for specimens loaded through knife edges. The critical load for the testing machine is the load at which one of the loading heads becomes laterally instable in relation to the other. For very short specimens the critical load was found to be less than the rated capacity given by the manufacturer for the machine. A load-length diagram is proposed for defining the safe limits of the test region for the machine. Although this report is particularly concerned with a universal testing machine of a certain type, the basic theory which led to the derivation of the general equation for the critical load, P (sub cr) = alpha L can be applied to any testing machine operated in compression where the specimen is loaded through knife edges. In this equation, L is the length of the specimen between knife edges and alpha is the force necessary to displace the upper end of the specimen unit horizontal distance relative to the lower end of the specimen in a direction normal to the knife edges through which the specimen is loaded.
Loading-rate-independent delay of catastrophic avalanches in a bulk metallic glass
Chen, S. H.; Chan, K. C.; Wang, G.; ...
2016-02-25
The plastic flow of bulk metallic glasses (BMGs) is characterized by intermittent bursts of avalanches, and this trend results in disastrous failures of BMGs. In the present work, a double-side-notched BMG specimen is designed, which exhibits chaotic plastic flows consisting of several catastrophic avalanches under the applied loading. The disastrous shear avalanches have, then, been delayed by forming a stable plastic-flow stage in the specimens with tailored distances between the bottoms of the notches, where the distribution of a complex stress field is acquired. Differing from the conventional compressive testing results, such a delaying process is independent of loading rate.more » The statistical analysis shows that in the specimens with delayed catastrophic failures, the plastic flow can evolve to a critical dynamics, making the catastrophic failure more predictable than the ones with chaotic plastic flows. Lastly, the findings are of significance in understanding the plastic-flow mechanisms in BMGs and controlling the avalanches in relating solids.« less
Composite materials for space applications
NASA Technical Reports Server (NTRS)
Rawal, Suraj P.; Misra, Mohan S.; Wendt, Robert G.
1990-01-01
The objectives of the program were to: generate mechanical, thermal, and physical property test data for as-fabricated advanced materials; design and fabricate an accelerated thermal cycling chamber; and determine the effect of thermal cycling on thermomechanical properties and dimensional stability of composites. In the current program, extensive mechanical and thermophysical property tests of various organic matrix, metal matrix, glass matrix, and carbon-carbon composites were conducted, and a reliable database was constructed for spacecraft material selection. Material property results for the majority of the as-fabricated composites were consistent with the predicted values, providing a measure of consolidation integrity attained during fabrication. To determine the effect of thermal cycling on mechanical properties, microcracking, and thermal expansion behavior, approximately 500 composite specimens were exposed to 10,000 cycles between -150 and +150 F. These specimens were placed in a large (18 cu ft work space) thermal cycling chamber that was specially designed and fabricated to simulate one year low earth orbital (LEO) thermal cycling in 20 days. With this rate of thermal cycling, this is the largest thermal cycling unit in the country. Material property measurements of the thermal cycled organic matrix composite laminate specimens exhibited less than 24 percent decrease in strength, whereas, the remaining materials exhibited less than 8 percent decrease in strength. The thermal expansion response of each of the thermal cycled specimens revealed significant reduction in hysteresis and residual strain, and the average CTE values were close to the predicted values.
Thermal barrier coating life prediction model development, phase 2
NASA Technical Reports Server (NTRS)
Meier, Susan Manning; Sheffler, Keith D.; Nissley, David M.
1991-01-01
The objective of this program was to generate a life prediction model for electron-beam-physical vapor deposited (EB-PVD) zirconia thermal barrier coating (TBC) on gas turbine engine components. Specific activities involved in development of the EB-PVD life prediction model included measurement of EB-PVD ceramic physical and mechanical properties and adherence strength, measurement of the thermally grown oxide (TGO) growth kinetics, generation of quantitative cyclic thermal spallation life data, and development of a spallation life prediction model. Life data useful for model development was obtained by exposing instrumented, EB-PVD ceramic coated cylindrical specimens in a jet fueled burner rig. Monotonic compression and tensile mechanical tests and physical property tests were conducted to obtain the EB-PVD ceramic behavior required for burner rig specimen analysis. As part of that effort, a nonlinear constitutive model was developed for the EB-PVD ceramic. Spallation failure of the EB-PVD TBC system consistently occurred at the TGO-metal interface. Calculated out-of-plane stresses were a small fraction of that required to statically fail the TGO. Thus, EB-PVD spallation was attributed to the interfacial cracking caused by in-plane TGO strains. Since TGO mechanical properties were not measured in this program, calculation of the burner rig specimen TGO in-plane strains was performed by using alumina properties. A life model based on maximum in-plane TGO tensile mechanical strain and TGO thickness correlated the burner rig specimen EB-PVD ceramic spallation lives within a factor of about plus or minus 2X.
Munikamaiah, Ranganath L; Jain, Saket K; Pal, Kapil S; Gaikwad, Ajay
2018-03-01
Silver colloidal nanoparticles have been incorporated into acrylic resins to induce antimicrobial properties. However, as additives, they can influence the mechanical properties of the final product. Mechanical properties are also dependent on different curing cycles. The aim of this study was to evaluate flexural strength of a denture base resin incorporated with different concentrations of silver colloidal nanoparticles subjected to two different curing cycles. Lucitone 199 denture base resin was used into which silver colloidal nanoparticles were incorporated at 0.5 and 5% by polymer mass. Specimens devoid of nanoparticles were used as controls. A total of 60 specimens were fabricated and divided into two groups. Each group was divided into three subgroups consisting of 10 specimens each. The specimens were fabricated according to American Dental Association (ADA) specification No. 12 and tested for flexural strength using universal testing machine. Silver colloidal nanoparticle incorporation at 0.5% concentration increased the mean flexural strength in both curing cycles by 7.5 and 4.4%, respectively, when compared with the control group. The study suggested that the mean flexural strength value of 0.5% silver colloidal nanoparticles in denture base resin was above the value of the control group both in short and long curing cycles, which makes it clinically suitable as a denture base material. However, at 5% concentration, the statistically significant amount of decrease in flexural strength compared with the value of control group both in short and long curing cycles gives it a questionable prognosis. The specimens incorporated with the antimicrobial agent 0.5% silver colloidal nanoparticles and processed by long curing cycles showed significant increase in its flexural strength compared with the control group, which makes it clinically suitable as a denture base material.
Detection of MPL mutations by a novel allele-specific PCR-based strategy.
Furtado, Larissa V; Weigelin, Helmut C; Elenitoba-Johnson, Kojo S J; Betz, Bryan L
2013-11-01
MPL mutation testing is recommended in patients with suspected primary myelofibrosis or essential thrombocythemia who lack the JAK2 V617F mutation. MPL mutations can occur at allelic levels below 15%, which may escape detection by commonly used mutation screening methods such as Sanger sequencing. We developed a novel multiplexed allele-specific PCR assay capable of detecting most recurrent MPL exon 10 mutations associated with primary myelofibrosis and essential thrombocythemia (W515L, W515K, W515A, and S505N) down to a sensitivity of 2.5% mutant allele. Test results were reviewed from 15 reference cases and 1380 consecutive specimens referred to our laboratory for testing. Assay performance was compared to Sanger sequencing across a series of 58 specimens with MPL mutations. Positive cases consisted of 45 with W515L, 6 with S505N, 5 with W515K, 1 with W515A, and 1 with both W515L and S505N. Seven cases had mutations below 5% that were undetected by Sanger sequencing. Ten additional cases had mutation levels between 5% and 15% that were not consistently detected by sequencing. All results were easily interpreted in the allele-specific test. This assay offers a sensitive and reliable solution for MPL mutation testing. Sanger sequencing appears insufficiently sensitive for robust MPL mutation detection. Our data also suggest the relative frequency of S505N mutations may be underestimated, highlighting the necessity for inclusion of this mutation in MPL test platforms. Copyright © 2013 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Investigation of the Leak Response of a Carbon-Fiber Laminate Loaded in Biaxial Tension
NASA Technical Reports Server (NTRS)
Jackson, Wade C.; Ratcliffe, James G.
2013-01-01
Designers of pressurized structures have been reluctant to use composite materials because of concerns over leakage. Biaxial stress states are expected to be the worst-case loading condition for allowing leakage to occur through microcracks. To investigate the leakage behavior under in-plane biaxial loading, a cruciform composite specimen was designed that would have a relatively large test section with a uniform 1:1 biaxial loading ratio. A 7.6-cm-square test section was desired for future investigations of the leakage response as a result of impact damage. Many iterations of the cruciform specimen were evaluated using finite element analysis to reduce stress concentrations and maximize the size of the uniform biaxial strain field. The final design allowed the specimen to go to relatively high biaxial strain levels without incurring damage away from the test section. The specimen was designed and manufactured using carbon/epoxy fabric with a four-ply-thick, quasi-isotropic, central test section. Initial validation and testing were performed on a specimen without impact damage. The specimen was tested to maximum biaxial strains of approximately 4500micro epsilon without apparent damage. A leak measurement system containing a pressurized cavity was clamped to the test section and used to measure the flow rate through the specimen. The leakage behavior of the specimen was investigated for pressure differences up to 172 kPa
Kapala, J.; Copes, D.; Sproston, A.; Patel, J.; Jang, D.; Petrich, A.; Mahony, J.; Biers, K.; Chernesky, M.
2000-01-01
Specimen pooling to achieve efficiency when testing urine specimens for Chlamydia trachomatis nucleic acids has been suggested. We pooled endocervical swabs from 1,288 women and also tested individual swabs by ligase chain reaction (LCR). Out of 53 positive specimens, pools of 4 or 8 specimens missed two positives, providing 96.2% accuracy compared to individual test results. Dilution and positive-control spiking experiments showed that negative specimens with inhibitors of LCR in the pool reduced the signal. Conversely, two extra positives, detected only through pooling, were negative by individual testing but became positive after storage, suggesting that fresh positive specimens with labile inhibitors may be positive in a pool because of dilution of inhibitors. For this population of women with a 4% prevalence of C. trachomatis infection, substantial savings in cost of reagents (55 to 63%) and technologist time (50 to 63%) made pooling strategies a desirable alternative to individual testing. PMID:10878029
Dias-Santagata, Dora; Wistuba, Ignacio I.; Chen, Heidi; Fujimoto, Junya; Kugler, Kelly; Franklin, Wilbur A.; Iafrate, A. John; Ladanyi, Marc; Kris, Mark G.; Johnson, Bruce E.; Bunn, Paul A.; Minna, John D.; Kwiatkowski, David J.
2015-01-01
Introduction Molecular genetic analyses of lung adenocarcinoma have recently become standard of care for treatment selection. The Lung Cancer Mutation Consortium was formed to enable collaborative multi-institutional analyses of 10 potential oncogenic driver mutations. Technical aspects of testing, and clinicopathologic correlations are presented. Methods Mutation testing in at least one of 8 genes (EGFR, KRAS, ERBB2, AKT1, BRAF, MEK1, NRAS, PIK3CA) using SNaPshot, mass spectrometry, Sanger sequencing +/− PNA and/or sizing assays, along with ALK and/or MET FISH were performed in 6 labs on 1007 patients from 14 institutions. Results 1007 specimens had mutation analysis performed, and 733 specimens had all 10 genes analyzed. Mutation identification rates did not vary by analytic method. Biopsy and cytology specimens were inadequate for testing in 26% and 35% of cases compared to 5% of surgical specimens. Among the 1007 cases with mutation analysis performed, EGFR, KRAS, ALK, and ERBB2 alterations were detected in 22, 25, 8.5, and 2.4% of cases, respectively. EGFR mutations were highly associated with female sex, Asian race, and never smoking status; and less strongly associated with stage IV disease, presence of bone metastases, and absence of adrenal metastases. ALK rearrangements were strongly associated with never smoking status, and more weakly associated with presence of liver metastases. ERBB2 mutations were strongly associated with Asian race and never smoking status. Two mutations were seen in 2.7% of samples, all but one of which involved one or more of PIK3CA, ALK or MET. Conclusion Multi-institutional molecular analysis across multiple platforms, sample types, and institutions can yield consistent results and novel clinicopathological observations. PMID:25738220
Seroepidemiology of dengue in travellers: a paired sera analysis.
Leder, Karin; Mutsch, Margot; Schlagenhauf, Patricia; Luxemburger, Christine; Torresi, Joseph
2013-01-01
Dengue is a frequent cause of fever in travellers. The true extent is unknown as many infections are asymptomatic or undiagnosed. We used paired sera, with pre- and post-travel specimens from Swiss travellers to tropical destinations, to evaluate the seroepidemiology of travel-related dengue. Post-travel specimens were tested for the presence of IgG and IgM antibodies to dengue antigen serotypes (1, 2, 3 and 4) using an indirect enzyme-linked immunosorbent assay (ELISA). All post-travel sera that screened as positive for dengue IgG or IgM antibodies were re-tested with the corresponding pre-travel sera as paired assays in order to detect seroconversion. There were 285 travellers with specimens available for analysis. Two hundred and fifty seven of the 285 individuals (90.2%) had negative dengue serology post-travel. Of the remaining 28 cases, 25 were dengue IgG positive and 3 had equivocal results. This corresponds to IgG seropositivity in 8.9%. Eighteen of these 25 individuals had a pre-travel specimen available for testing, of which 15 were positive for IgG consistent with possible past exposure. Three of the 18 had negative serology pre-travel, indicating possible recent infection. This corresponds to an attack rate of possible dengue of 1.1% and an incidence rate of 6.7 per 1000 person-months (95% CI 0-60.0). Two of these three individuals had received yellow fever vaccine for their trip, raising the potential of cross-reactivity. The confirmed dengue attack rate therefore was 0.23% with a corresponding incidence rate of 2.2 per 1000 person-months (95% CI-0-33.1). Seroepidemiology provides additional evidence of an appreciable risk of acute dengue infection among travellers to tropical destinations. Copyright © 2013. Published by Elsevier Ltd.
Wimmer, Timea; Huffmann, Anne Mildred Sophie; Eichberger, Marlis; Schmidlin, Patrick R; Stawarczyk, Bogna
2016-06-01
To test and compare the two-body wear rate of three CAD/CAM polymer materials and the influence of specimen geometry, antagonist material and test set-up configuration. Three CAD/CAM polymeric materials were assessed: a thermoplastic polyetheretherketone (PEEK), an experimental nanohybrid composite (COMP) and a PMMA-based material (PMMA). Crown-shaped and flat specimens were prepared from each material. The specimens underwent thermo-mechanical loading (50N, 5/55°C; 600,000 chewing cycles) opposed to human enamel and stainless steel antagonists. Half of the specimens of each group were loaded with a sliding movement of 0.7mm, the remaining half without. Thereby, 24 different test set-ups were investigated (n=12). Wear of the materials and antagonists was evaluated with a match-3D procedure. The topography of all surfaces was examined with scanning electron microscopy (SEM). Data were statistically evaluated with four-/one-way ANOVA followed by Scheffé post hoc test and unpaired t-test (p<0.05). All PEEK specimens showed significantly less material loss than COMP and PMMA specimens when loaded laterally. Within the axial loaded groups this was only true for the flat specimens tested with enamel antagonists. Crown specimens of these groups exhibited lower loss values than flat ones. Lateral force application led mostly to significantly higher material loss than the axial load application. On the antagonist side, no impact of CAD/CAM polymer material, antagonist material, force application and specimen geometry was found. Wear of PEEK was lower than that of the resin-based materials when lateral forces were applied, but showed comparable antagonist wear rates at the same time. Copyright © 2016 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
49 CFR 40.161 - What does the MRO do when a drug test specimen is rejected for testing?
Code of Federal Regulations, 2011 CFR
2011-10-01
... negative test is required (e.g., in the case of a pre-employment, return-to-duty, or follow-up test). (c... 49 Transportation 1 2011-10-01 2011-10-01 false What does the MRO do when a drug test specimen is... Verification Process § 40.161 What does the MRO do when a drug test specimen is rejected for testing? As the...
49 CFR 40.161 - What does the MRO do when a drug test specimen is rejected for testing?
Code of Federal Regulations, 2010 CFR
2010-10-01
... negative test is required (e.g., in the case of a pre-employment, return-to-duty, or follow-up test). (c... 49 Transportation 1 2010-10-01 2010-10-01 false What does the MRO do when a drug test specimen is... Verification Process § 40.161 What does the MRO do when a drug test specimen is rejected for testing? As the...
49 CFR 40.161 - What does the MRO do when a drug test specimen is rejected for testing?
Code of Federal Regulations, 2012 CFR
2012-10-01
... negative test is required (e.g., in the case of a pre-employment, return-to-duty, or follow-up test). (c... 49 Transportation 1 2012-10-01 2012-10-01 false What does the MRO do when a drug test specimen is... Verification Process § 40.161 What does the MRO do when a drug test specimen is rejected for testing? As the...
49 CFR 40.161 - What does the MRO do when a drug test specimen is rejected for testing?
Code of Federal Regulations, 2014 CFR
2014-10-01
... negative test is required (e.g., in the case of a pre-employment, return-to-duty, or follow-up test). (c... 49 Transportation 1 2014-10-01 2014-10-01 false What does the MRO do when a drug test specimen is... Verification Process § 40.161 What does the MRO do when a drug test specimen is rejected for testing? As the...
49 CFR 40.161 - What does the MRO do when a drug test specimen is rejected for testing?
Code of Federal Regulations, 2013 CFR
2013-10-01
... negative test is required (e.g., in the case of a pre-employment, return-to-duty, or follow-up test). (c... 49 Transportation 1 2013-10-01 2013-10-01 false What does the MRO do when a drug test specimen is... Verification Process § 40.161 What does the MRO do when a drug test specimen is rejected for testing? As the...
Gibson, Jane; Schechter-Perkins, Elissa M; Mitchell, Patricia; Mace, Sharon; Tian, Yu; Williams, Kemi; Luo, Robert; Yen-Lieberman, Belinda
2017-10-01
Point of Care Testing (POCT) provides the capability for rapid laboratory test results in patient care environments where a traditional clinical laboratory is not available. POCTs have shorter turn-around times (TATs), they may be performed by non-laboratory personnel, and the need for transport time is eliminated. The Food and Drug Administration (FDA) recently granted Clinical Laboratory Improvements Amendment (CLIA) waiver status to the cobas ® Influenza A/B & RSV assay, a rapid, accurate point-of-care test for Influenza and respiratory syncytial virus (RSV) performed on the Liat ® System. The performance characteristics of this test were determined though a multi-site study consisting of different point of care testing environments. Prospectively collected Nasopharyngeal (NP) swabs from 1361 patients seen at 8 primary care clinics and 4 emergency departments (EDs) and 295 retrospectively identified specimens were tested for Influenza A/B and RSV on the cobas ® Liat ® platform. Performance characteristics were determined through comparison to ProFlu+, a laboratory-based PCR test for Influenza A/B and RSV (reference test). Discordant specimens were adjudicated following bi-directional sequencing. The cobas ® Influenza A/B and RSV assay showed sensitivities of 99.6%, 99.3%, and 96.8% for Influenza A, Influenza B, and RSV, respectively as determined from percent positive agreement (PPA) following comparison to the reference test. Sequencing confirmed cobas ® Influenza A/B and RSV results in 49.2% of reference test discordant specimens, while crossing threshold data suggest increased sensitivity compared to the reference test. The cobas ® Influenza A/B and RSV assay was found to be a rapid, sensitive POCT for the detection of these viruses, and provides laboratory-quality PCR-based diagnostic results in point of care settings. Copyright © 2017 Elsevier B.V. All rights reserved.
Kwon, So Ran; Kurti, Steven R; Oyoyo, Udochukwu; Li, Yiming
2015-09-01
The purpose of this study was to evaluate the effect of four whitening modalities on surface enamel as assessed with microhardness tester, profilometer, and scanning electron microscopy (SEM). Whitening was performed according to manufacturer's directions for over-the-counter (OTC), dentist dispensed for home use (HW) and in-office (OW) whitening. Do-it-yourself (DIY) whitening consisted of a strawberry and baking soda mix. Additionally, negative and positive controls were used. A total of 120 enamel specimens were used for microhardness testing at baseline and post-whitening. Following microhardness testing specimens were prepared for SEM observations. A total of 120 enamel specimens were used for surface roughness testing at baseline and post-whitening (n = 20 per group). Rank-based Analysis of Covariance was performed to compare microhardness and surface roughness changes. Tests of hypotheses were two-sided with α = 0.05. There was a significant difference in Knoop hardness changes (ΔKHN) among the groups (Kruskal-Wallis test, p < 0.0001). Significant hardness reduction was observed in the positive control and DIY group (p < 0.0001). Mean surface roughness changes (ΔRa) were significantly different among the groups (Kruskal-Wallis test, p < 0.0001). Surface roughness increased in the OTC group (p = 0.03) and in the positive control (p < 0.0001). The four whitening modalities-DIY, OTC, HW and OW induced minimal surface morphology changes when observed with SEM. It can be concluded that none of the four whitening modalities adversely affected enamel surface morphology. However, caution should be advised when using a DIY regimen as it may affect enamel microhardness and an OTC product as it has the potential to increase surface roughness.
Acoustic emission analysis of fiber-reinforced composite in flexural testing.
Alander, Pasi; Lassila, Lippo V J; Tezvergil, Arzu; Vallittu, Pekka K
2004-05-01
The aim of this study was to examine the emission of acoustic signals from six commercially available fiber-reinforced composites (FRC) used in the frameworks of fixed partial dentures in material bending. FRC test specimens were made of six commercially available fiber products of polyethylene or glass and five light-curing resins. FRC test specimens were polymerized with a hand light-curing unit or with a light-curing oven. The flexural test for determination of ultimate flexural strength of test specimens (n = 6) was based on the ISO 10477 standard after the specimens were stored in air or in water for two weeks. The acoustic emission (AE) signals were monitored during three-point loading test of the test specimens using a test with increasing loading levels until the specimens fractured. Generally, stress level required for the AE activity initiation ranged from 107 MPa (Ribbond) to 579 MPa (everStick). The ultimate flexural strength of FRC specimens were higher, ranging from 132 to 764 MPa, being highest with everStick and Vectris FRC, and lowest with Ribbond FRC. ANOVA showed a statistically significant difference between the initiation of AE activity and the ultimate flexural strength according to the brand (p < 0.001) storing conditions (p < 0.001) and polymerization procedure (p < 0.001). AE activity and ultimate flexural strength correlated significantly (p < 0.010, r = 0.887). The result of this study suggested that AE activity in FRC specimens started at a 19-32% lower stress level than occurred at final fracture.
Biaxial Testing of 2195 Aluminum Lithium Alloy Using Cruciform Specimens
NASA Technical Reports Server (NTRS)
Johnston, W. M.; Pollock, W. D.; Dawicke, D. S.; Wagner, John A. (Technical Monitor)
2002-01-01
A cruciform biaxial test specimen was used to test the effect of biaxial load on the yield of aluminum-lithium alloy 2195. Fifteen cruciform specimens were tested from 2 thicknesses of 2195-T8 plate, 0.45 in. and 1.75 in. These results were compared to the results from uniaxial tensile tests of the same alloy, and cruciform biaxial tests of aluminum alloy 2219-T87.
Gaglani, Manjusha; Naleway, Allison; Reynolds, Sue; Ball, Sarah; Bozeman, Sam; Henkle, Emily; Meece, Jennifer; Vandermause, Mary; Clipper, Lydia; Thompson, Mark
2013-01-01
In our prospective cohort study, we compared the performance of nasopharyngeal, oropharyngeal, and nasal swabs for the detection of influenza virus using real-time reverse transcription-PCR assay. Joint consideration of results from oropharyngeal and nasal swabs was as effective as consideration of results from nasopharyngeal swabs alone, as measured by sensitivity and noninferiority analysis. PMID:24108606
Verification Study - Wah Wah Valley, Utah. Volume I. Synthesis.
1981-03-24
Paleozoic limestone and dolomite , with lesser amounts of Precambrian and Cambrian quartzites and phyllites. Tertiary volcanic rocks, consisting of...of fracture along which there has been gdisplacement. FAULT BLOCK MOUNTAINS - Mountains that are formed by normal faulting in which the surface crust...sample (ASTM D 2850-70). To conduct the test, a cylindrical specimen of soil is surrounded by a fluid in a pressure chamber and subjected to an
1992-07-01
NONDESTRUCTIVE INSPECTION Probabilistic Durability Evaluation of Alcoa 7050 Aluminum ............................... 305 Composite Repair of Aircraft Structures... Aluminum J.G. Burns, WLIFIBEC 0900-0930 Composite Repair of Aircraft Structures - The Australian Experience L. Molent, Aeronautical Research Laboratory...fatigue test articles consisted of a of 5 percent from the calculated airframe ratio of 2124-T851 aluminum specimen surrounded by 0.882, to preclude
Wallis, Carole; Pahalawatta, Vihanga; Frank, Andrea; Ramdin, Neeshan; Viana, Raquel; Abravaya, Klara; Leckie, Gregor; Tang, Ning
2015-01-01
The Abbott RealTime MTB assay is a nucleic acid amplification test (NAAT) for the detection of Mycobacterium tuberculosis complex DNA. The sample inactivation procedure used in the assay, consisting of one part sample treated with 3 parts inactivation reagent for 60 min, effectively reduced viscosity and inactivated M. tuberculosis in clinical specimens. PMID:26085611
Yunes-Díaz, Elsa; Ruiz, Patricia Alonso-de; Lazcano-Ponce, Eduardo
2015-05-01
An assessment was performed of the quality of Pap readings in 19 cytology laboratories (CLs) in Mexico from the Cervical Cancer Screening Program. Nine CLs were affiliated with the Health Ministry (SSA), and ten were affiliated with the Mexican Social Security Institute (IMSS). Two sets of 200 cervical cytology specimens were prepared, one set for each institution. Fourteen percent of the specimens were positive and six were inappropriate for diagnosis (3%). All cervical cytology specimens were processed in the cytopathology laboratory at the General Hospital of Mexico, and histopathology was available for each positive case. Thirty percent of the SSA reading centers had a sensitivity of at least 80%; however, not one of the ten IMSS laboratories evaluated reached this figure. Some reading centers had a sensitivity <65%, meaning that nearly half of the specimens with a cytology consistent with cervical neoplasm were not identified. Given these results, it is a priority to effect a paradigm shift combining various screening tests to improve adherence to standards and enhanced cost-effectiveness of the early detection of cervicouterine cancer (CC) in Mexico. Copyright © 2015 IMSS. Published by Elsevier Inc. All rights reserved.
Evaluation of composite flattened tubular specimen. [fatigue tests
NASA Technical Reports Server (NTRS)
Liber, T.; Daniel, I. M.
1978-01-01
Flattened tubular specimens of graphite/epoxy, S-glass/epoxy, Kevlar-49/epoxy, and graphite/S-glass/epoxy hybrid materials were evaluated under static and cyclic uniaxial tensile loading and compared directly with flat coupon data of the same materials generated under corresponding loading conditions. Additional development for the refinement of the flattened specimen configuration and fabrication was required. Statically tested graphite/epoxy, S-glass/epoxy, and Kevlar 49/epoxy flattened tube specimens exhibit somewhat higher average strengths than their corresponding flat coupons. Flattened tube specimens of the graphite/S-glass/epoxy hybrid and the graphite/epoxy flattened tube specimens failed in parasitic modes with consequential lower strength than the corresponding flat coupons. Fatigue tested flattened tube specimens failed in parasitic modes resulting in lower fatigue strengths than the corresponding flat coupons.
Data fusion in X-ray computed tomography using a superiorization approach.
Schrapp, Michael J; Herman, Gabor T
2014-05-01
X-ray computed tomography (CT) is an important and widespread inspection technique in industrial non-destructive testing. However, large-sized and heavily absorbing objects cause artifacts due to either the lack of penetration of the specimen in specific directions or by having data from only a limited angular range of views. In such cases, valuable information about the specimen is not revealed by the CT measurements alone. Further imaging modalities, such as optical scanning and ultrasonic testing, are able to provide data (such as an edge map) that are complementary to the CT acquisition. In this paper, a superiorization approach (a newly developed method for constrained optimization) is used to incorporate the complementary data into the CT reconstruction; this allows precise localization of edges that are not resolvable from the CT data by itself. Superiorization, as presented in this paper, exploits the fact that the simultaneous algebraic reconstruction technique (SART), often used for CT reconstruction, is resilient to perturbations; i.e., it can be modified to produce an output that is as consistent with the CT measurements as the output of unmodified SART, but is more consistent with the complementary data. The application of this superiorized SART method to measured data of a turbine blade demonstrates a clear improvement in the quality of the reconstructed image.
NASA Technical Reports Server (NTRS)
Farley, Gary L.; Seshadri, Banavara R.
2005-01-01
An analysis based investigation of aluminum with metal matrix composite selectively reinforced single- and multi-hole specimens was performed and their results compared with results from geometrically comparable non-reinforced specimens. All reinforced specimens exhibited a significant increase in performance. Performance increase of up to 170 percent was achieved. Specimen failure modes were consistent with results from reinforced polymeric matrix composite specimens. Localized reinforcement application (circular) proved as effective as a broader area (strip) reinforcement. Also, selective reinforcement is an excellent method of increasing the performance of multi-hole specimens.
On impact testing of subsize Charpy V-notch type specimens
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mikhail, A.S.; Nanstad, R.K.
1994-12-31
The potential for using subsize specimens to determine the actual properties of reactor pressure vessel steels is receiving increasing attention for improved vessel condition monitoring that could be beneficial for light-water reactor plant-life extension. This potential is made conditional upon, on the one hand, by the possibility of cutting samples of small volume from the internal surface of the pressure vessel for determination of actual properties of the operating pressure vessel. The plant-life extension will require supplemental surveillance data that cannot be provided by the existing surveillance programs. Testing of subsize specimens manufactured from broken halves of previously tested surveillancemore » Charpy V-notch (CVN) specimens offers an attractive means of extending existing surveillance programs. Using subsize CVN type specimens requires the establishment of a specimen geometry that is adequate to obtain a ductile-to-brittle transition curve similar to that obtained from full-size specimens. This requires the development of a correlation of transition temperature and upper-shelf toughness between subsize and full-size specimens. The present study was conducted under the Heavy-Section Steel Irradiation Program. Different published approaches to the use of subsize specimens were analyzed and five different geometries of subsize specimens were selected for testing and evaluation. The specimens were made from several types of pressure vessel steels with a wide range of yield strengths, transition temperatures, and upper-shelf energies (USEs). Effects of specimen dimensions, including depth, angle, and radius of notch have been studied. The correlation of transition temperature determined from different types of subsize specimens and the full-size specimen is presented. A new procedure for transforming data from subsize specimens was developed and is presented.« less
Lombos, Ernesto; Tang, Elaine; Perusini, Stephen; Eshaghi, Alireza; Nagra, Sandeep; Frantz, Christine; Olsha, Romy; Kristjanson, Erik; Dimitrova, Kristina; Safronetz, David; Drebot, Mike
2017-01-01
ABSTRACT With the emerging Zika virus (ZIKV) epidemic, accessible real-time reverse transcription-PCR (rRT-PCR) assays are needed to streamline testing. The commercial Altona Diagnostics RealStar ZIKV rRT-PCR test kit (Altona PCR) has been approved for emergency use authorization by the U.S. FDA. Our aim was to verify the Altona PCR by comparing it to the CDC-designed dual-target ZIKV rRT-PCR reference assay (reference PCR) and describe the demographics of patients tested for ZIKV by rRT-PCR in Ontario, Canada. A large set of clinical specimens was tested for ZIKV by the Altona PCR and the reference PCR. Positive or equivocal specimens underwent PCR and Sanger sequencing targeting the ZIKV NS5 gene. A total of 671 serum specimens were tested by the reference PCR: 58 (8.6%) were positive, 193 (28.8%) were equivocal, and 420 (62.6%) were negative. Ninety percent of the reference PCR-positive patients were tested in the first 5 days after symptom onset. The Altona PCR was performed on 284/671 specimens tested by the reference PCR. The Altona PCR was positive for 53/58 (91%) reference PCR-positive specimens and 16/193 (8%) reference PCR-equivocal specimens; the ZIKV NS5 PCR was positive for all 68 Altona PCR-positive specimens and negative for all 181 Altona PCR-negative specimens that underwent the NS5 PCR. The Altona PCR has very good sensitivity (91%) and specificity (97%) compared to the reference PCR. The Altona PCR can be used for ZIKV diagnostic testing and has less extensive verification requirements than a laboratory-developed test. PMID:28298448
Development of fracture mechanics data for two hydrazine APU turbine wheel materials
NASA Technical Reports Server (NTRS)
Curbishley, G.
1975-01-01
The effects of high temperature, high pressure ammonia were measured on the fracture mechanics and fatigue properties of Astroloy and Rene' 41 turbine wheel materials. Also, the influence of protective coatings on these properties was investigated. Specimens of forged bar stock were subjected to LCF and HCF tests at 950 K (1250 F) and 3.4 MN/sq m (500 psig) pressure, in ammonia containing about 1.5 percent H2O. Aluminized samples (Chromizing Company's Al-870) and gold plated test bars were compared with uncoated specimens. Comparison tests were also run in air at 950 K (1250 F), but at ambient pressures. K sub IE and K sub TH were determined on surface flawed specimens in both the air and ammonia in both uncoated and gold plated conditions. Gold plated specimens exhibited better properties than uncoated samples, and aluminized test bars generally had lower properties. The fatigue properties of specimens tested in ammonia were higher than those tested in air, yet the K sub TH values of ammonia tested samples were lower than those tested in air. However, insufficient specimens were tested to develop significant design data.
NASA Astrophysics Data System (ADS)
Mousavi Nezhad, Mohaddeseh; Fisher, Quentin J.; Gironacci, Elia; Rezania, Mohammad
2018-06-01
Reliable prediction of fracture process in shale-gas rocks remains one of the most significant challenges for establishing sustained economic oil and gas production. This paper presents a modeling framework for simulation of crack propagation in heterogeneous shale rocks. The framework is on the basis of a variational approach, consistent with Griffith's theory. The modeling framework is used to reproduce the fracture propagation process in shale rock samples under standard Brazilian disk test conditions. Data collected from the experiments are employed to determine the testing specimens' tensile strength and fracture toughness. To incorporate the effects of shale formation heterogeneity in the simulation of crack paths, fracture properties of the specimens are defined as spatially random fields. A computational strategy on the basis of stochastic finite element theory is developed that allows to incorporate the effects of heterogeneity of shale rocks on the fracture evolution. A parametric study has been carried out to better understand how anisotropy and heterogeneity of the mechanical properties affect both direction of cracks and rock strength.
Behavior of Steel-Sheathed Shear Walls Subjected to Seismic and Fire Loads.
Hoehler, Matthew S; Smith, Christopher M; Hutchinson, Tara C; Wang, Xiang; Meacham, Brian J; Kamath, Praveen
2017-07-01
A series of tests was conducted on six 2.7 m × 3.7 m shear wall specimens consisting of cold-formed steel framing sheathed on one side with sheet steel adhered to gypsum board and on the opposite side with plain gypsum board. The specimens were subjected to various sequences of simulated seismic shear deformation and fire exposure to study the influence of multi-hazard interactions on the lateral load resistance of the walls. The test program was designed to complement a parallel effort at the University of California, San Diego to investigate a six-story building subjected to earthquakes and fires. The test results reported here indicate that the fire exposure caused a shift in the failure mode of the walls from local buckling of the sheet steel in cases without fire exposure, to global buckling of the sheet steel with an accompanying 35 % reduction in lateral load capacity after the wall had been exposed to fire. This behavior appears to be predictable, which is encouraging from the standpoint of residual lateral load capacity under these severe multi-hazard actions.
Compatibility of an FeCrAl alloy with flowing Pb-Li in a thermal convection loop
NASA Astrophysics Data System (ADS)
Pawel, Steven J.; Unocic, Kinga A.
2017-08-01
A mono-metallic thermal convection loop (TCL) fabricated from alloy APMT (Fe21Cr5Al3Mo) tubing and filled with 0.025 m long tensile specimens of the same alloy was operated continuously for 1000 h with commercially pure Pb-17 at.%Li (Pb-Li) at a peak temperature of 550 ± 1.5 °C and a temperature gradient of ∼116 °C. The resulting Pb-Li flow rate was ∼0.0067 m/s. A 1050 °C pre-oxidation treatment (to form an external alumina scale) given to most specimens exposed within the TCL decreased total mass loss by a factor of 3-30 compared to adjacent specimens that were not pre-oxidized. However, all specimens exposed above 500 °C lost mass suggesting that the alumina scale was not entirely stable in flowing Pb-Li at these temperatures. Post-exposure room temperature tensile tests indicated that the mechanical properties of APMT were substantially influenced by extended exposures in the range of 435-490 °C, which caused an increase in yield strength (∼65%) and a corresponding decrease in ductility associated with α‧ embrittlement. Specimens annealed in argon at the same temperature exhibited identical changes without exposure to Pb-Li. Scanning transmission electron microscopy revealed Cr-clusters within the microstructure in specimens exposed in the low temperature regions (<490 °C) of the TCL, indicating the formation of α‧ consistent with the mechanism of α‧ embrittlement.
Three-Body Abrasion Testing Using Lunar Dust Simulants to Evaluate Surface System Materials
NASA Technical Reports Server (NTRS)
Kobrick, Ryan L.; Budinski, Kenneth G.; Street, Kenneth W., Jr.; Klaus, David M.
2010-01-01
Numerous unexpected operational issues relating to the abrasive nature of lunar dust, such as scratched visors and spacesuit pressure seal leaks, were encountered during the Apollo missions. To avoid reoccurrence of these unexpected detrimental equipment problems on future missions to the Moon, a series of two- and three-body abrasion tests were developed and conducted in order to begin rigorously characterizing the effect of lunar dust abrasiveness on candidate surface system materials. Two-body scratch tests were initially performed to examine fundamental interactions of a single particle on a flat surface. These simple and robust tests were used to establish standardized measurement techniques for quantifying controlled volumetric wear. Subsequent efforts described in the paper involved three-body abrasion testing designed to be more representative of actual lunar interactions. For these tests, a new tribotester was developed to expose samples to a variety of industrial abrasives and lunar simulants. The work discussed in this paper describes the three-body hardware setup consisting of a rotating rubber wheel that applies a load on a specimen as a loose abrasive is fed into the system. The test methodology is based on ASTM International (ASTM) B611, except it does not mix water with the abrasive. All tests were run under identical conditions. Abraded material specimens included poly(methyl methacrylate) (PMMA), hardened 1045 steel, 6061-T6 aluminum (Al) and 1018 steel. Abrasives included lunar mare simulant JSC- 1A-F (nominal size distribution), sieved JSC-1A-F (<25 m particle diameter), lunar highland simulant NU-LHT-2M, alumina (average diameter of 50 m used per ASTM G76), and silica (50/70 mesh used per ASTM G65). The measured mass loss from each specimen was converted using standard densities to determine total wear volume in cm3. Abrasion was dominated by the alumina and the simulants were only similar to the silica (i.e., sand) on the softer materials of aluminum and PMMA. The nominal JSC- 1A-F consistently showed more abrasion wear than the sieved version of the simulant. The lunar dust displayed abrasivity to all of the test materials, which are likely to be used in lunar landing equipment. Based on this test experience and pilot results obtained, recommendations are made for systematic abrasion testing of candidate materials intended for use in lunar exploration systems and in other environments with similar dust challenges.
NASA Technical Reports Server (NTRS)
Jackson, A.; Sandifer, J.; Sandorff, P.; Vancleave, R.
1984-01-01
Twenty-two specimens of each of two key structural elements of the Advance Composite Vertical Fin (ACVF) were fabricated and tested. One element represented the front spar at the fuselage attachment area and the other element represented the cover at the fuselage joint area. Ten specimens of each element were selected for static testing. The coefficient of variation resulting from the tests was 3.28 percent for the ten cover specimens and 6.11 percent for the ten spar specimens, which compare well with metallic structures. The remaining twelve cover and twelve spar specimens were durability tested in environmental chambers which permitted the temperature and humidity environment to be cycled as well as the applied loads. Results of the durability tests indicated that such components will survive the service environment.
Estimating Trabecular Bone Mechanical Properties From Non-Invasive Imaging
NASA Technical Reports Server (NTRS)
Hogan, Harry A.; Webster, Laurie
1997-01-01
An important component in developing countermeasures for maintaining musculoskeletal integrity during long-term space flight is an effective and meaningful method of monitoring skeletal condition. Magnetic resonance imaging (MRI) is an attractive non-invasive approach because it avoids the exposure to radiation associated with X-ray based imaging and also provides measures related to bone microstructure rather than just density. The purpose of the research for the 1996 Summer Faculty Fellowship period was to extend the usefulness of the MRI data to estimate the mechanical properties of trabecular bone. The main mechanical properties of interest are the elastic modulus and ultimate strength. Correlations are being investigated between these and fractal analysis parameters, MRI relaxation times, apparent densities, and bone mineral densities. Bone specimens from both human and equine donors have been studied initially to ensure high-quality MR images. Specimens were prepared and scanned from human proximal tibia bones as well as the equine distal radius. The quality of the images from the human bone appeared compromised due to freezing artifact, so only equine bone was included in subsequent procedures since these specimens could be acquired and imaged fresh before being frozen. MRI scans were made spanning a 3.6 cm length on each of 5 equine distal radius specimens. The images were then sent to Dr. Raj Acharya of the State University of New York at Buffalo for fractal analysis. Each piece was cut into 3 slabs approximately 1.2 cm thick and high-resolution contact radiographs were made to provide images for comparing fractal analysis with MR images. Dual energy X-ray absorptiometry (DEXA) scans were also made of each slab for subsequent bone mineral density determination. Slabs were cut into cubes for mechanical using a slow-speed diamond blade wafering saw (Buehler Isomet). The dimensions and wet weights of each cube specimen were measured and recorded. Wet weights were also recorded. Each specimen was labeled and marked to denote anatomic orientations, i.e. superior/inferior (S/I), media/lateral (M/L), and anterior/posterior (A/P). The actual locations of each cube cut were documented and images distributed to define ROI locations for other analyses (to Raj Acharya for fractal analysis, to Jon Richardson at Baylor College of Medicine for DEXA, and to Chen Lin at Baylor College of Medicine for T2* MRI analysis). Quasistatic mechanical testing consisted of compressive loading in all three mutually perpendicular anatomic directions. Cyclic loading was applied for 10 cycles to precondition the specimen and results calculated for the eleventh. For one of three directions tested on each specimen, the 10 cycles were followed with loading to failure. Testing is currently proceeding and once completed the results will be correlated with data from the other analyses. One of the main points of interest is the relationship between fractal dimension and mechanical properties. Throughout preparation and testing all specimens were maintained hydrated with physiological saline and stored frozen when not being used.
Laser-heated rotating specimen autoignition test
NASA Technical Reports Server (NTRS)
Au, A. C.
1988-01-01
Specimens of 440 C steel were rotated in a chamber pressurized with oxygen gas and heated with a 5-kW CO2 laser to determine the temperature required for autoignition to occur. Tests included exposures of static and rotating (25,000 rpm) specimens in oxygen pressurized to 5.51 MPa, and with focused laser fluences of more than 3.5 billion W/sq m. Specimen surface temperatures were monitored with a scanning infrared camera. Temperature measurement difficulties were experienced due to a problem with internal reflection inside the test chamber; however, posttest specimen examinations confirmed that surface melt (1371 C) was achieved in several tests. No sustained combustion was initiated in any rotating specimen. One static specimen was ignited. Results indicated that conditions necessary for autoignition of 440 C steel are more dependent on specimen geometry and available heat removal mechanisms. Sustained combustion occurred in the ignited static specimen with an estimated 130 C/sec cooling rate due to conduction. The rotating specimens could not sustain combustion due to a greater conductive/convective cooling rate of about 4000 C/sec and ejection of molten material. These results were applied to the Space Shuttle Main Engine (SSME) oxygen turbopump bearings to conclude that the LOX-cooled 440 C steel bearings cannot sustain combustion initiated by skidding friction.
Thermal fatigue and oxidation data for alloy/braze combinations
NASA Technical Reports Server (NTRS)
Hill, V. L.; Humphreys, V. E.
1977-01-01
Thermal fatigue and oxidation data were obtained for 62 brazed specimens of 3 iron-, 3 nickel-, and 1 cobalt-base alloy. Fluidized bed thermal cycling was conducted over the range 740/25 C employing 10 cm long single-edge wedge specimens. Immersion time was always 4 minutes in each bed. Types of test specimens employed in the program include those with brazed overlays on the specimen radius, those butt brazed at midspan and those with a brazed foil overlay on the specimen radius. Of the 18 braze overlay specimens, 5 generated fatigue cracks by 7000 cycles. Thermal cracking of butt brazed specimens occurred exclusively through the butt braze. Of the 23 butt brazed specimens, 7 survived 11,000 thermal cycles without cracking. Only 2 of the 21 foil overlaid specimens exhibiting cracking in 7,000 cycles. Blistering of the foil did occur for 2 alloys by 500 cycles. Oxidation of the alloy/braze combination was limited at the test maximum test temperature of 740 C.
NASA Technical Reports Server (NTRS)
Jones, R. A. (Inventor)
1974-01-01
The square root of the product of thermophysical properties q, c and k, where p is density, c is specific heat and k is thermal conductivity, is determined directly on a test specimen such as a wind tunnel model. The test specimen and a reference specimen of known specific heat are positioned at a given distance from a heat source. The specimens are provided with a coating, such as a phase change coating, to visually indicate that a given temperature was reached. A shutter interposed between the heat source and the specimens is opened and a motion picture camera is actuated to provide a time record of the heating step. The temperature of the reference specimen is recorded as a function of time. The heat rate to which both the test and reference specimens were subjected is determined from the temperature time response of the reference specimen by the conventional thin-skin calorimeter equation.
2007-06-01
of the N720/A specimen tested in creep at –4.0 MPa at 1200 °C in steam for 100 h. This specimen was unloaded, but remained at 1200°C for the...the N720/A specimen tested in creep at –4.0 MPa at 1200 °C in steam for 100 h. This specimen was unloaded, but remained at 1200°C for the duration...tested in creep at –4.0 MPa at 1200 °C in steam for 100 h. This specimen was unloaded, but remained at 1200°C for the duration of the test
Grain size-sensitive viscoelastic relaxation and seismic properties of polycrystalline MgO
NASA Astrophysics Data System (ADS)
Barnhoorn, A.; Jackson, I.; Fitz Gerald, J. D.; Kishimoto, A.; Itatani, K.
2016-07-01
Torsional forced-oscillation experiments on a suite of synthetic MgO polycrystals, of high-purity and average grain sizes of 1-100 µm, reveal strongly viscoelastic behavior at temperatures of 800-1300°C and periods between 1 and 1000 s. The measured shear modulus and associated strain energy dissipation both display monotonic variations with oscillation period, temperature, and grain size. The data for the specimens of intermediate grain size have been fitted to a generalized Burgers creep function model that is also broadly consistent with the results for the most coarse-grained specimen. The mild grain size sensitivity for the relaxation time τL, defining the lower end of the anelastic absorption band, is consistent with the onset of elastically accommodated grain boundary sliding. The upper end of the anelastic absorption band, evident in the highest-temperature data for one specimen only, is associated with the Maxwell relaxation time τM marking the transition toward viscous behavior, conventionally ascribed a stronger grain size sensitivity. Similarly pronounced viscoelastic behavior was observed in complementary torsional microcreep tests, which confirm that the nonelastic strains are mainly recoverable, i.e., anelastic. With an estimated activation volume for the viscoelastic relaxation, the experimentally constrained Burgers model has been extrapolated to the conditions of pressure and temperature prevailing in the Earth's uppermost lower mantle. For a plausible grain size of 10 mm, the predicted dissipation Q-1 ranges from 10-3 to 10-2 for periods of 3-3000 s. Broad consistency with seismological observations suggests that the lower mantle ferropericlase phase might account for much of its observed attenuation.
NASA Technical Reports Server (NTRS)
Rummel, W. D.; Rathke, R. A.; Todd, P. H., Jr.; Mullen, S. J.
1975-01-01
Liquid penetrant, ultrasonic, eddy current and X-radiographic techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens in integrally stiffened panel, and weld panel configurations. Fatigue cracks in integrally stiffened panels, lack-of-fusion in weld panels, and fatigue cracks in weld panels were the flaw types used for evaluation. A 2319 aluminum alloy weld filler rod was used for all welding to produce the test specimens. Forty seven integrally stiffened panels containing a total of 146 fatigue cracks, ninety three lack-of-penetration (LOP) specimens containing a total of 239 LOP flaws, and one-hundred seventeen welded specimens containing a total of 293 fatigue cracks were evaluated. Nondestructive test detection reliability enhancement was evaluated during separate inspection sequences in the specimens in the 'as-machined or as-welded', post etched and post proof loaded conditions. Results of the nondestructive test evaluations were compared to the actual flaw size obtained by measurement of the fracture specimens after completing all inspection sequences. Inspection data were then analyzed to provide a statistical basis for determining the flaw detection reliability.
Snyder, K. A.; Ferraris, C.; Martys, N. S.; Garboczi, E. J.
2000-01-01
The suitability of using the initial current from the rapid chloride test (ASTM C 1202) to determine specimen conductivity is tested using impedance spectroscopy with a frequency spectrum of 10 Hz to 1 MHz. The specimen conductivity has an analytical relationship to specimen diffusivity and so is a useful quantity in service life prediction. Measurements made on specimens of different lengths indicate that the total charge passed during the six hour conduction test carried out according to ASTM C 1202 is not a direct measure of specimen conductivity. Further, ohmic heating during the 6 hour test makes it nearly impossible to directly measure any specimen transport property from the results. The total charge passed during the 6 hour conduction test is, therefore, not a reliable quantity for service life prediction. Results indicate that the direct current (dc) measurement of resistance using a voltage of 60 V is sufficient to overwhelm polarization effects, thereby yielding an accurate estimate of the true specimen conductivity. Impedance spectroscopy measurements also indicate that corrosion may form on the brass electrodes, adding bias to a conductivity estimate based upon a dc measurement. PMID:27551618
Static and fatigue interlaminar tensile characterization of laminated composites
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koudela, K.L.; Strait, L.H.; Caiazzo, A.A.
1997-12-31
Spool and curved-beam specimens were evaluated to determine the viability of using either one or both of these configurations to characterize the static and fatigue interlaminar tensile behavior of carbon/epoxy laminates. Unidirectional curved-beam and quasi-isotropic spool specimens were fabricated, nondestructively inspected, and statically tested to failure. Tension-tension fatigue tests were conducted at 10 Hz and an R-ratio ({sigma}{sub min}/{sigma}{sub max}) equal to 0.1 for each specimen configuration. The interlaminar tensile strength of the spool specimen was 12% larger than the strength obtained using curved-beam specimens. In addition, data scatter associated with spool specimens was significantly less than the scatter associatedmore » with curved-beam specimens. The difference in data scatter was attributed to the influence of the fabrication process on the quality of the laminates tested. The fatigue limit at 0{sup 7} cycles for both specimen types was shown to be at least 40% of the average interlaminar tensile strength. Based on the results of this study, it was concluded that either the spool or the curved-beam specimens can be used to characterize the interlaminar tensile static and fatigue behavior of carbon/epoxy laminates. However, to obtain the most representative results, the test specimen configuration should be selected so that the specimen fabrication process closely simulates the actual component fabrication process.« less
A novel hybrid joining methodology for composite to steel joints
NASA Astrophysics Data System (ADS)
Sarh, Bastian
This research has established a novel approach for designing, analyzing, and fabricating load bearing structural connections between resin infused composite materials and components made of steel or other metals or alloys. A design philosophy is proposed wherein overlapping joint sections comprised of fiber reinforced plastics (FRP's) and steel members are connected via a combination of adhesive bonding and integrally placed composite pins. A film adhesive is utilized, placed into the dry stack prior to resin infusion and is cured after infusion through either local heat elements or by placing the structure into an oven. The novel manner in which the composite pins are introduced consists of perforating the steel member with holes and placing pre-formed composite pins through them, also prior to resin infusion of the composite section. In this manner joints are co-molded structures such that secondary processing is eliminated. It is shown that such joints blend the structural benefits of adhesive and mechanically connected joints, and that the fabrication process is feasible for low-cost, large-scale production as applicable to the shipbuilding industry. Analysis procedures used for designing such joints are presented consisting of an adhesive joint design theory and a pin placement theory. These analysis tools are used in the design of specimens, specific designs are fabricated, and these evaluated through structural tests. Structural tests include quasi-static loading and low cycle fatigue evaluation. This research has thereby invented a novel philosophy on joints, created the manufacturing technique for fabricating such joints, established simple to apply analysis procedures used in the design of such joints (consisting of both an adhesive and a pin placement analysis), and has validated the methodology through specimen fabrication and testing.
Specimen's plane misaligned installation solution based on charge fluctuation inside SEM
NASA Astrophysics Data System (ADS)
Lu, Haojian; Liu, Yanting; Yang, Yuanyuan; Wang, Panbing; Shen, Yajing
2018-04-01
Precise specimen's installation is a sticking point to ensure the characterization accuracy of the in-situ material property test. Although it is common knowledge that specimen's plane misaligned installation (PMI) would cause extra force loading during mechanical testing, there are few effective solutions available to deal with it at the current stage, especially during the in-situ scanning electron microscopy (SEM) test. Taking into consideration the charge fluctuation phenomenon under SEM, this paper proposes a highlight area variation (HAV) method for specimen deformation judgment, i.e., the specimen deformation is defined when the highlight area changes greater than 20% of the initial value of the specimen surface. Three types of specimens with different resistivities, i.e., human hair (electrical resistivity ˜3 × 1012 Ω cm), optical fiber (electrical resistivity ˜1017 Ω cm), and magnetic wire (electrical resistivity ˜2 × 10-5 Ω cm), are chosen to verify the effectiveness of the HAV method. Furthermore, combined with the developed robot-aided alignment system, the specimen's PMI problem can also be solved. In the demonstration, the human hair specimen is installed across two specimen stages and its in-situ twisting (in 360°) test is implemented. The results clearly indicate that the HAV method and the robot-aided alignment system are practical and reliable, and the specimen can be aligned on the same plane and installed precisely with accuracy up to 3 μm. This method will benefit the in-situ SEM material mechanical property test and has a significant impact in fundamental material research.
Improved sensitivity of vaginal self-collection and high-risk human papillomavirus testing.
Belinson, Jerome L; Du, Hui; Yang, Bin; Wu, Ruifang; Belinson, Suzanne E; Qu, Xinfeng; Pretorius, Robert G; Yi, Xin; Castle, Philip E
2012-04-15
Self-collected vaginal specimens tested for high-risk human papillomavirus (HR-HPV) have been shown to be less sensitive for the detection of cervical intraepithelial neoplasia or cancer (≥CIN 3) than physician-collected endocervical specimens. To increase the sensitivity of self-collected specimens, we studied a self-sampling device designed to obtain a larger specimen from the upper vagina (POI/NIH self-sampler) and a more sensitive polymerase chain reaction (PCR)-based HR-HPV assay. Women (10,000) were screened with cervical cytology and HR-HPV testing of vaginal self-collected and endocervical physician-collected specimens. Women were randomly assigned to use either a novel self-collection device (POI/NIH self-sampler) or conical-shaped brush (Qiagen). The self-collected and clinician-collected specimens were assayed by Cervista (Hologic) and the research only PCR-based matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF). Women with any abnormal screening test underwent colposcopy and biopsy. Women (8,556), mean age of 38.9, had complete data; 1.6% had ≥ CIN 3. For either HR-HPV assay, the sensitivity was similar for the two self-collection devices. Tested with Cervista, the sensitivity for ≥CIN 3 of self-collected specimens was 70.9% and for endocervical specimens was 95.0% (p = 0.0001). Tested with MALDI-TOF, the sensitivity for ≥CIN 3 of self-collected specimens was 94.3% and for endocervical specimens was also 94.3% (p = 1.0). A self-collected sample using a PCR-based assay with the capability of very high throughput has similar sensitivity as a direct endocervical specimen obtained by a physician. Large population-based screening "events" in low-resource settings could be achieved by promoting self-collection and centralized high-throughput, low-cost testing by PCR-based MALDI-TOF. Copyright © 2011 UICC.
NASA Astrophysics Data System (ADS)
Pena, A. E.; Kuntaegowdanahalli, S. S.; Abbas, J. J.; Patrick, J.; Horch, K. W.; Jung, R.
2017-12-01
Objective. A neural interface system has been developed that consists of an implantable stimulator/recorder can with a 15-electrode lead that trifurcates into three bundles of five individual wire longitudinal intrafascicular electrodes. This work evaluated the mechanical fatigue resistance of the branched lead and distributed electrode system under conditions designed to mimic anticipated strain profiles that would be observed after implantation in the human upper arm. Approach. Custom test setups and procedures were developed to apply linear or angular strain at four critical stress riser points on the lead and electrode system. Each test was performed to evaluate fatigue under a high repetition/low amplitude paradigm designed to test the effects of arm movement on the leads during activities such as walking, or under a low repetition/high amplitude paradigm designed to test the effects of more strenuous upper arm activities. The tests were performed on representative samples of the implantable lead system for human use. The specimens were fabricated using procedures equivalent to those that will be used during production of human-use implants. Electrical and visual inspections of all test specimens were performed before and after the testing procedures to assess lead integrity. Main results. Measurements obtained before and after applying repetitive strain indicated that all test specimens retained electrical continuity and that electrical impedance remained well below pre-specified thresholds for detection of breakage. Visual inspection under a microscope at 10× magnification did not reveal any signs of damage to the wires or silicone sheathing at the stress riser points. Significance. These results demonstrate that the branched lead of this implantable neural interface system has sufficient mechanical fatigue resistance to withstand strain profiles anticipated when the system is implanted in an arm. The novel test setups and paradigms may be useful in testing other lead systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurtz, R.J.; Jones, R.H.; Johnson, W.R.
1997-04-01
Two fatigue precracked compact tension (CT) specimens of V-4Cr-4Ti were statically loaded to a stress intensity factor of about 30 MPa{radical}m in room temperature DIII-D water. The first specimen was tested for a period of about 30 days and the second specimen for about 54 days. At the conclusion of each test the specimens were fractured, and the fracture surfaces examined with a scanning electron microscope (SEM) to determine if SCC had occurred. No SCC was found in either test specimen.
NASA Technical Reports Server (NTRS)
Mendreck, M. J.; Hurless, B. E.; Torres, P. D.; Danford, M. D.
1998-01-01
The corrosion and stress corrosion cracking (SCC) characteristics of annealed and hardened 440C stainless steel were evaluated in high humidity and 3.5-percent NaCl solution. Corrosion testing consisted of an evaluation of flat plates, with and without grease, in high humidity, as well as electrochemical testing in 3.5-percent NaCl. Stress corrosion testing consisted of conventional, constant strain, smooth bar testing in high humidity in addition to two relatively new techniques under evaluation at MSFC. These techniques involve either incremental or constant rate increases in the load applied to a precracked SE(B) specimen, monitoring the crack-opening-displacement response for indications of crack growth. The electrochemical corrosion testing demonstrated an order of magnitude greater general corrosion rate in the annealed 440C. All techniques for stress corrosion testing showed substantially better SCC resistance in the annealed material. The efficacy of the new techniques for stress corrosion testing was demonstrated both by the savings in time and the ability to better quantify SCC data.
NASA Technical Reports Server (NTRS)
McCutcheon, David Matthew
2017-01-01
During the structural certification effort for the Space Launch System solid rocket booster nozzle, it was identified that no consistent method for addressing local negative margins of safety in non-metallic materials had been developed. Relevant areas included bond-line terminations and geometric features in the composite nozzle liners. In order to gain understanding, analog test specimens were designed that very closely mimic the conditions in the actual full scale hardware. Different locations in the nozzle were represented by different analog specimen designs. This paper describes those tests and corresponding results. Finite element analysis results for the tests are presented. Strain gage correlation of the analysis to the test results is addressed. Furthermore, finite fracture mechanics (a coupled stress and energy failure criterion) is utilized to predict the observed crack pop-in loads for the different configurations. The finite fracture mechanics predictions are found to be within a 10% error relative to the average measured pop-in load for each of four configurations. Initiation locations, arrest behaviors, and resistances to further post-arrest crack propagation are also discussed.
NASA Technical Reports Server (NTRS)
Collette, J. G. R.
1984-01-01
A test was conducted in the NASA/Ames Research Center 9x7-foot Supersonic Wind Tunnel to help resolve an anomaly that developed during the STS-6 orbiter flight wherein sections of the Advanced Flexible Reusable Surface Insulation (AFRSI) covering the OMS pods suffered some damage. A one-third scale two-dimensional shell structure model of an OMS pod cross-section was employed to support the test articles. These consisted of 15 AFRSI blanket panels form-fitted over the shell structures for exposure to simulated flight conditions. Of six baseline blankets, two were treated with special surface coatings. Two other panels were configured with AFRSI sections removed from the OV099 orbiter vehicle after the STS-6 flight. Seven additional specimens incorporated alternative designs and repairs. Following a series of surface pressure calibration runs, the specimens were exposed to simulated ascent and entry dynamic pressure profiles. Entry conditions included the use of a vortex generator to evaluate the effect of shed vortices on the AFRSI located in the area of concern.
Life Cycle Testing of Viscoelastic Material for Hubble Space Telescope Solar Array 3 Damper
NASA Technical Reports Server (NTRS)
Maly, Joseph R.; Reed, Benjamin B.; Viens, Michael J.; Parker, Bradford H.; Pendleton, Scott C.
2003-01-01
During the March 2002 Servicing Mission by Space Shuttle (STS 109), the Hubble Space Telescope (HST) was refurbished with two new solar arrays that now provide all of its power. These arrays were built with viscoelastic/titanium dampers, integral to the supporting masts, which reduce the interaction of the wing bending modes with the Telescope. Damping of over 3% of critical was achieved. To assess the damper s ability to maintain nominal performance over the 10-year on-orbit design goal, material specimens were subjected to an accelerated life test. The test matrix consisted of scheduled events to expose the specimens to pre-determined combinations of temperatures, frequencies, displacement levels, and numbers of cycles. These exposure events were designed to replicate the life environment of the damper from fabrication through testing to launch and life on-orbit. To determine whether material degradation occurred during the exposure sequence, material performance was evaluated before and after the accelerated aging with complex stiffness measurements. Based on comparison of pre- and post-life-cycle measurements, the material is expected to maintain nominal performance through end of life on-orbit. Recent telemetry from the Telescope indicates that the dampers are performing nominally.
Shah, Alok Girish; Shetty, Pradeep Chandra; Ramachandra, C S; Bhat, N Sham; Laxmikanth, S M
2011-11-01
To assess the antiadherent and antibacterial properties of surface modified stainless steel orthodontic brackets with photocatalytic titanium oxide (TiO(2)) against Lactobacillus acidophilus. This study was done on 120 specimens of stainless steel preadjusted edgewise appliance (PEA) orthodontic brackets. The specimens were divided into four test groups. Each group consisted of 30 specimens. Groups containing uncoated brackets acted as a control group for their respective experimental group containing coated brackets. Surface modification of brackets was carried out by the radiofrequency (RF) magnetron sputtering method with photocatalytic TiO(2). Brackets then were subjected to microbiological tests for assessment of the antiadherent and antibacterial properties of photocatalytic TiO(2) coating against L acidophilus. Orthodontic brackets coated with photocatalytic TiO(2) showed an antiadherent effect against L acidophilus compared with uncoated brackets. The bacterial mass that was bound to the TiO(2)-coated brackets was less when compared with the uncoated brackets. Furthermore, TiO(2)-coated brackets had a bactericidal effect on L acidophilus, which causes dental caries. Surface modification of orthodontic brackets with photocatalytic TiO(2) can be used to prevent the accumulation of dental plaque and the development of dental caries during orthodontic treatment.
Apparatus for testing for infection by a retrovirus
Layne, Scott P.; Beugelsdijk, Tony J.
1999-01-01
An apparatus for testing specimens for infection by a retrovirus is described. The apparatus comprises a process controller including a communications module for translating user commands into test instrument suite commands and a means for communicating specimen test results to a user. The apparatus further comprises a test instrument suite including a means for treating the specimen to manifest an observable result and a detector for measuring the observable result.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 1 2013-10-01 2013-10-01 false What does the second laboratory do with the split specimen when it is tested to reconfirm a substituted test result? 40.181 Section 40.181 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Split Specimen Tests § 40.181...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 1 2013-10-01 2013-10-01 false What does the second laboratory do with the split specimen when it is tested to reconfirm an adulterated test result? 40.179 Section 40.179 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Split Specimen Tests § 40.17...
49 CFR 40.173 - Who is responsible for paying for the test of a split specimen?
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 1 2013-10-01 2013-10-01 false Who is responsible for paying for the test of a split specimen? 40.173 Section 40.173 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Split Specimen Tests § 40.173 Who is responsible for paying for the test of a spli...
Simulated Service and Stress Corrosion Cracking Testing for Friction Stir Welded Spun Form Domes
NASA Technical Reports Server (NTRS)
Stewart, Thomas J.; Torres, Pablo D.; Caratus, Andrei A.; Curreri, Peter A.
2010-01-01
Damage tolerance testing development was required to help qualify a new spin forming dome fabrication process for the Ares 1 program at Marshall Space Flight Center (MSFC). One challenge of the testing was due to the compound curvature of the dome. The testing was developed on a sub-scale dome with a diameter of approximately 40 inches. The simulated service testing performed was based on the EQTP1102 Rev L 2195 Aluminum Lot Acceptance Simulated Service Test and Analysis Procedure generated by Lockheed Martin for the Space Shuttle External Fuel Tank. This testing is performed on a specimen with an induced flaw of elliptical shape generated by Electrical Discharge Machining (EDM) and subsequent fatigue cycling for crack propagation to a predetermined length and depth. The specimen is then loaded in tension at a constant rate of displacement at room temperature until fracture occurs while recording load and strain. An identical specimen with a similar flaw is then proof tested at room temperature to imminent failure based on the critical offset strain achieved by the previous fracture test. If the specimen survives the proof, it is then subjected to cryogenic cycling with loads that are a percentage of the proof load performed at room temperature. If all cryogenic cycles are successful, the specimen is loaded in tension to failure at the end of the test. This standard was generated for flat plate, so a method of translating this to a specimen of compound curvature was required. This was accomplished by fabricating a fixture that maintained the curvature of the specimen rigidly with the exception of approximately one-half inch in the center of the specimen containing the induced flaw. This in conjunction with placing the center of the specimen in the center of the load train allowed for successful testing with a minimal amount of bending introduced into the system. Stress corrosion cracking (SCC) tests were performed using the typical double beam assembly and with 4-point loaded specimens under alternate immersion conditions in a 3.5% NaCl environment for 90 days. In addition, experiments were conducted to determine the threshold stress intensity factor for SCC (K1SCC) of Al-Li 2195 which to our knowledge has not been determined previously. The successful simulated service and stress corrosion testing helped to provide confidence to continue to Ares 1 scale dome fabrication.
Machine for use in monitoring fatigue life for a plurality of elastomeric specimens
NASA Technical Reports Server (NTRS)
Fitzer, G. E. (Inventor)
1977-01-01
An improved machine is described for use in determining the fatigue life for elastomeric specimens. The machine is characterized by a plurality of juxtaposed test stations, specimen support means located at each of the test stations for supporting a plurality of specimens of elastomeric material, and means for subjecting the specimens at each of said stations to sinusoidal strain at a strain rate unique with respect to the strain rate at which the specimens at each of the other stations is subjected to sinusoidal strain.
Overload and Underload Effects on the Fatigue Crack Growth Behavior of the 2024-T3 Aluminum Alloy
NASA Technical Reports Server (NTRS)
Dawicke, David S.
1997-01-01
Fatigue crack growth tests were conducted on 0.09 inch thick, 3.0 inch wide middle-crack tension specimens cut from sheets of 2024-T3 aluminum alloy. The tests were conducted using a load sequence that consisted of a single block of 2,500 cycles of constant amplitude loading followed by an overload/underload combination. The largest fatigue crack growth life occurred for the tests with the overload stress equal to 2 times the constant amplitude stress and the underload stress equal to the constant amplitude minimum stress. For the tests with compressive underloads, the fatigue crack growth life decreased with increasing compressive underload stress.
Ageing under mechanical stress: first experiments for a silver based multilayer mirror
NASA Astrophysics Data System (ADS)
Lalo, Arnaud; Ravel, Guillaume; Ignat, Michel; Cousin, Bernard; Swain, Michael V.
2017-11-01
Improving materials and devices reliability is a major concern to the spatial industry. Results are reported for satellite mirrors-like specimens consisting in oxide-protected metal systems. Optical coatings were deposited by electron beam evaporation. Mechanical stress fields in multi-layered materials play an important role. The stress state can have far-reaching implications both in kinetics and thermodynamics. Therefore an integrated apparatus with four-point bending equipment was designed. The technique allowed us to exert stress into a film or a system of films on a substrate concurrently with thermal treatment. In order to achieve the first tests performed with the help of the apparatus, various preliminary characterizations were required. The article reports the preliminary micro-mechanical testing of the materials (ultra micro-indentation to evaluate the elastic modulus of the samples materials and wafer curvature technique to determine the specimen residual stress) and the first ageing experiment. Experimental evidence of accelerated ageing under stress is successfully reported.
Holden, Brad; Guice, Erica A
2014-05-01
In clinical and forensic toxicology laboratories, one commonly used method for urine specimen validity testing is creatinine concentration. In this study, workplace guidelines are examined to determine their relevance to forensic and clinical toxicology samples. Specifically, it investigates the occurrence of urine creatinine concentrations under 20 mg/dL and notes potential issues with factors influencing creatinine concentration by utilizing a simple, novel method consisting of cation-paring high-pressure liquid chromatography in tandem with ultraviolet detection to determine the creatinine concentration in 3019 donors. Of the 4227 sample population in this study, 209 (4.94%) were below the cutoff value of 20 mg/dL for dilute urine. Because there are many factors that can influence the urinary creatinine concentration, samples that have creatinine under the 20 mg/dL cutoff do not always implicate sample adulteration. © 2014 American Academy of Forensic Sciences.
Skin penetration assessment of less lethal kinetic energy munitions.
Bir, Cynthia A; Stewart, Shelby J; Wilhelm, Marianne
2005-11-01
The development of less-lethal technologies has provided law enforcement personnel with an alternative to lethal force. Although the less lethal projectile was produced to engender non-penetrating wounds, case studies show that there have been a number of reported penetrating injuries ranging from minor to significant in morbidity. The objective of this study was to determine the energy per unit area required to penetrate various regions of the body. Eight unembalmed postmortem human specimens were procured for this testing. Each specimen sustained a maximum of 25 impacts consisting of shots to the anterior and posterior thorax, abdomen, and legs. A 12-gauge, fin-stabilized, rubber rocket round was used as the impactor for all of the conducted tests. The energy density required for 50% risk of penetration varied from 23.99 J/cm2 for the location on the anterior rib (p = 0.000) to 52.74 J/cm2 for the location on the posterior rib (p = 0.001).
Application of subsize specimens in nuclear plant life extension
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosinski, S.T.; Kumar, A.S.; Cannon, S.C.
1991-01-01
The US Department of Energy is sponsoring a research effort through Sandia National Laboratories and the University of Missour-Rolla to test a correlation for the upper shelf energy (USE) values obtained from the impact testing of subsize Charpy V-notch specimens to those obtained from the testing of full size samples. The program involves the impact testing of unirradiated and irradiated full, half, and third size Charpy V-notch specimens. To verify the applicability of the correlation on LWR materials unirradiated and irradiated full, half, and third size Charpy V-notch specimens of a commercial pressure vessel steel (ASTM A533 Grade B) willmore » be tested. This paper will provide details of the program and present results obtained from the application of the developed correlation methodology to the impact testing of the unirradiated full, half, and third size A533 Grade B Charpy V-notch specimens.« less
Application of subsize specimens in nuclear plant life extension
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosinski, S.T.; Kumar, A.S.; Cannon, S.C.
1991-12-31
The US Department of Energy is sponsoring a research effort through Sandia National Laboratories and the University of Missour-Rolla to test a correlation for the upper shelf energy (USE) values obtained from the impact testing of subsize Charpy V-notch specimens to those obtained from the testing of full size samples. The program involves the impact testing of unirradiated and irradiated full, half, and third size Charpy V-notch specimens. To verify the applicability of the correlation on LWR materials unirradiated and irradiated full, half, and third size Charpy V-notch specimens of a commercial pressure vessel steel (ASTM A533 Grade B) willmore » be tested. This paper will provide details of the program and present results obtained from the application of the developed correlation methodology to the impact testing of the unirradiated full, half, and third size A533 Grade B Charpy V-notch specimens.« less
Automated Microbiological Detection/Identification System
Aldridge, C.; Jones, P. W.; Gibson, S.; Lanham, J.; Meyer, M.; Vannest, R.; Charles, R.
1977-01-01
An automated, computerized system, the AutoMicrobic System, has been developed for the detection, enumeration, and identification of bacteria and yeasts in clinical specimens. The biological basis for the system resides in lyophilized, highly selective and specific media enclosed in wells of a disposable plastic cuvette; introduction of a suitable specimen rehydrates and inoculates the media in the wells. An automated optical system monitors, and the computer interprets, changes in the media, with enumeration and identification results automatically obtained in 13 h. Sixteen different selective media were developed and tested with a variety of seeded (simulated) and clinical specimens. The AutoMicrobic System has been extensively tested with urine specimens, using a urine test kit (Identi-Pak) that contains selective media for Escherichia coli, Proteus species, Pseudomonas aeruginosa, Klebsiella-Enterobacter species, Serratia species, Citrobacter freundii, group D enterococci, Staphylococcus aureus, and yeasts (Candida species and Torulopsis glabrata). The system has been tested with 3,370 seeded urine specimens and 1,486 clinical urines. Agreement with simultaneous conventional (manual) cultures, at levels of 70,000 colony-forming units per ml (or more), was 92% or better for seeded specimens; clinical specimens yielded results of 93% or better for all organisms except P. aeruginosa, where agreement was 86%. System expansion in progress includes antibiotic susceptibility testing and compatibility with most types of clinical specimens. Images PMID:334798
NASA Astrophysics Data System (ADS)
Nuraini, Lutviasari; Prifiharni, Siska; Priyotomo, Gadang; Sundjono, Gunawan, Hadi
2017-03-01
Antifouling paints are used widely to coat the underwater structures to prevent various fouling organisms. The evaluation of the performance for the two commercial anticorrosion and antifouling paints was carried out in the piles of Suramadu Bridge, East Java during 1 month exposure. The 20 cm width × 25 cm high × 0.3 cm thick specimens of mild steel were sandblasted and coated by anticorrosion and antifouling paint. Blank specimen (without exposed) were also prepared as a control. On the other hand, the 7.5 cm width × 15 cm high × 0.3 cm thick specimen bare mild steel was prepared for measure the corrosion rate throught weight loss method. The test panels containing specimens were exposure up to 1 month for immersion in splash zone and tidal zone (0, 1, 3, meters from sea level). Sea water parameters consisting of temperature, pH, salinity, conductivity and dissolved oxygen (DO) were also measured. The thickness, glossy, hardness and adhesion strength of the coating performance were carried out. The results show that both surfaces of anticorrosive paint and bare mild steel specimen covered by fouling organisms, whereas no fouling took place on the surface of antifouling paint. The corrosion rate of bare mild steel in the 0, 1, and 3 meters are 15.1;13.7 and 17.0 mpy, respectively.
Karbhari, Vistasp M; Strassler, Howard
2007-08-01
The aim of this study was to compare and elucidate the differences in damage mechanisms and response of fiber-reinforced dental resin composites based on three different brands under flexural loading. The types of reinforcement consisted of a unidirectional E-glass prepreg (Splint-It from Jeneric/Petron Inc.), an ultrahigh molecular weight polyethylene fiber based biaxial braid (Connect, Kerr) and an ultrahigh molecular weight polyethylene fiber based leno-weave (Ribbond). Three different commercially available fiber reinforcing systems were used to fabricate rectangular bars, with the fiber reinforcement close to the tensile face, which were tested in flexure with an emphasis on studying damage mechanisms and response. Eight specimens (n=8) of each type were tested. Overall energy capacity as well as flexural strength and modulus were determined and results compared in light of the different abilities of the architectures used. Under flexural loading unreinforced and unidirectional prepreg reinforced dental composites failed in a brittle fashion, whereas the braid and leno-weave reinforced materials underwent significant deformation without rupture. The braid reinforced specimens showed the highest peak load. The addition of the unidirectional to the matrix resulted in an average strain of 0.06mm/mm which is 50% greater than the capacity of the unreinforced matrix, whereas the addition of the braid and leno-weave resulted in increases of 119 and 126%, respectively, emphasizing the higher capacity of both the UHM polyethylene fibers and the architectures to hold together without rupture under flexural loading. The addition of the fiber reinforcement substantially increases the level of strain energy in the specimens with the maximum being attained in the braid reinforced specimens with a 433% increase in energy absorption capability above the unreinforced case. The minimum scatter and highest consistency in response is seen in the leno-weave reinforced specimens due to the details of the architecture which restrict fabric shearing and movement during placement. It is crucial that the appropriate selection of fiber architectures be made not just from a perspective of highest strength, but overall damage tolerance and energy absorption. Differences in weaves and architectures can result in substantially different performance and appropriate selection can mitigate premature and catastrophic failure. The study provides details of materials level response characteristics which are useful in selection of the fiber reinforcement based on specifics of application.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davenport, Michael; Petti, D. A.
The United States Department of Energy’s Advanced Reactor Technologies (ART) Program will irradiate up to six nuclear graphite creep experiments in the Advanced Test Reactor (ATR) located at the Idaho National Laboratory (INL). The graphite experiments are being irradiated over an approximate eight year period to support development of a graphite irradiation performance data base on the new nuclear grade graphites now available for use in high temperature gas reactors. The goals of the irradiation experiments are to obtain irradiation performance data, including irradiation creep, at different temperatures and loading conditions to support design of the Very High Temperature Gasmore » Reactor (VHTR), as well as other future gas reactors. The experiments each consist of a single capsule that contain six stacks of graphite specimens, with half of the graphite specimens in each stack under a compressive load, while the other half of the specimens are not be subjected to a compressive load during irradiation. The six stacks have differing compressive loads applied to the top half of diametrically opposite pairs of specimen stacks. A seventh specimen stack in the center of the capsule does not have a compressive load. The specimens are being irradiated in an inert sweep gas atmosphere with on-line temperature and compressive load monitoring and control. There are also samples taken of the sweep gas effluent to measure any oxidation or off-gassing of the specimens that may occur during initial start-up of the experiment. The first experiment, AGC-1, started its irradiation in September 2009, and the irradiation was completed in January 2011. The second experiment, AGC-2, started its irradiation in April 2011 and completed its irradiation in May 2012. The third experiment, AGC-3, started its irradiation in late November 2012 and completed in the April of 2014. AGC-4 is currently being irradiated in the ATR. This paper will briefly discuss the preliminary irradiation results of the AGC-4 experiment, as well as the design of AGC-5.« less
Time-Dependent Behavior of High-Strength Kevlar and Vectran Webbing
NASA Technical Reports Server (NTRS)
Jones, Thomas C.; Doggett, William R.
2014-01-01
High-strength Kevlar and Vectran webbings are currently being used by both NASA and industry as the primary load-bearing structure in inflatable space habitation modules. The time-dependent behavior of high-strength webbing architectures is a vital area of research that is providing critical material data to guide a more robust design process for this class of structures. This paper details the results of a series of time-dependent tests on 1-inch wide webbing including an initial set of comparative tests between specimens that underwent realtime and accelerated creep at 65 and 70% of their ultimate tensile strength. Variability in the ultimate tensile strength of the webbings is investigated and compared with variability in the creep life response. Additional testing studied the effects of load and displacement rate, specimen length and the time-dependent effects of preconditioning the webbings. The creep test facilities, instrumentation and test procedures are also detailed. The accelerated creep tests display consistently longer times to failure than their real-time counterparts; however, several factors were identified that may contribute to the observed disparity. Test setup and instrumentation, grip type, loading scheme, thermal environment and accelerated test postprocessing along with material variability are among these factors. Their effects are discussed and future work is detailed for the exploration and elimination of some of these factors in order to achieve a higher fidelity comparison.
16 CFR Figures 3 and 4 to Subpart... - Test Specimens
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Test Specimens 3 Figures 3 and 4 to Subpart A of Part 1201 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT... Figures 3 and 4 to Subpart A of Part 1201—Test Specimens EC03OC91.006 ...
16 CFR Figures 3 and 4 to Subpart... - Test Specimens
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Test Specimens 3 Figures 3 and 4 to Subpart A of Part 1201 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT... Figures 3 and 4 to Subpart A of Part 1201—Test Specimens EC03OC91.006 ...
16 CFR Figures 3 and 4 to Subpart... - Test Specimens
Code of Federal Regulations, 2012 CFR
2012-01-01
... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Test Specimens 3 Figures 3 and 4 to Subpart A of Part 1201 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT... Figures 3 and 4 to Subpart A of Part 1201—Test Specimens EC03OC91.006 ...
10 CFR 26.159 - Assuring specimen security, chain of custody, and preservation.
Code of Federal Regulations, 2010 CFR
2010-01-01
... licensee testing facility has retained the specimen in Bottle B, the licensee testing facility shall... the licensee testing facility. (2) The following are exclusive grounds requiring the MRO to cancel the... or legal challenge until they are no longer needed. (j) The laboratory shall discard a valid specimen...
49 CFR 40.3 - What do the terms used in this part mean?
Code of Federal Regulations, 2010 CFR
2010-10-01
... one that requires further testing for drugs or drug metabolites. Initial specimen validity test. The... specimen. A specimen that has been altered, as evidenced by test results showing either a substance that is... endogenous substance. Affiliate. Persons are affiliates of one another if, directly or indirectly, one...
NASA Technical Reports Server (NTRS)
Gutierrez-Lemini, Danton; McCool, Alex (Technical Monitor)
2001-01-01
A method is developed to establish the J-resistance function for an isotropic linear viscoelastic solid of constant Poisson's ratio using the single-specimen technique with constant-rate test data. The method is based on the fact that, for a test specimen of fixed crack size under constant rate, the initiation J-integral may be established from the crack size itself, the actual external load and load-point displacement at growth initiation, and the relaxation modulus of the viscoelastic solid, without knowledge of the complete test record. Since crack size alone, of the required data, would be unknown at each point of the load-vs-load-point displacement curve of a single-specimen test, an expression is derived to estimate it. With it, the physical J-integral at each point of the test record may be established. Because of its basis on single-specimen testing, not only does the method not require the use of multiple specimens with differing initial crack sizes, but avoids the need for tracking crack growth as well.
Seismic Behaviour of Composite Steel Fibre Reinforced Concrete Shear Walls
NASA Astrophysics Data System (ADS)
Boita, Ioana-Emanuela; Dan, Daniel; Stoian, Valeriu
2017-10-01
In this paper is presented an experimental study conducted at the “Politehnica” University of Timisoara, Romania. This study provides results from a comprehensive experimental investigation on the behaviour of composite steel fibre reinforced concrete shear walls (CSFRCW) with partially or totally encased profiles. Two experimental composite steel fibre reinforced concrete walls (CSFRCW) and, as a reference specimen, a typical reinforced concrete shear wall (RCW), (without structural reinforcement), were fabricated and tested under constant vertical load and quasi-static reversed cyclic lateral loads, in displacement control. The tests were performed until failure. The tested specimens were designed as 1:3 scale steel-concrete composite elements, representing a three storeys and one bay element from the base of a lateral resisting system made by shear walls. Configuration/arrangement of steel profiles in cross section were varied within the specimens. The main objective of this research consisted in identifying innovative solutions for composite steel-concrete shear walls with enhanced performance, as steel fibre reinforced concrete which was used in order to replace traditional reinforced concrete. A first conclusion was that replacing traditional reinforcement with steel fibre changes the failure mode of the elements, as from a flexural mode, in case of element RCW, to a shear failure mode for CSFRCW. The maximum lateral force had almost similar values but test results indicated an improvement in cracking response, and a decrease in ductility. The addition of steel fibres in the concrete mixture can lead to an increase of the initial cracking force, and can change the sudden opening of a crack in a more stable process.
NASA Technical Reports Server (NTRS)
Phillips, E. P.
1974-01-01
Specimens of Ti-6Al-4V titanium alloy sheet in the annealed and the solution-treated and aged heat-treatment condition were exposed outdoors at ambient and 560 K (550 F) temperatures to determine the effect of outdoor exposure on fatigue life. Effects of exposure were determined by comparing fatigue lives of exposed specimens to those of unexpected specimens. Two procedures for fatigue testing the exposed specimens were evaluated: (1) fatigue tests conducted outdoors by applying 1200 load cycles per week until failure occurred and (2) conventional fatigue tests (continuous cycling until failure occurred) conducted indoors after outdoor exposure under static load. The exposure period ranged from 9 to 28 months for the outdoor fatigue-test group and was 24 months for the static-load group. All fatigue tests were constant-amplitude bending of specimens containing a drilled hole (stress concentration factor of 1.6). The results of the tests indicate that the fatigue lives of solution-treated and aged specimens were significantly reduced by the outdoor exposure at 560 K but not by the exposure at ambient temperature. Fatigue lives of the annealed specimens were essentially unaffected by the outdoor exposure at either temperature. The two test procedures - outdoor fatigue test and indoor fatigue test after outdoor exposure - led to the same conclusions about exposure effects.
The Use of Doublers in Delamination Toughness Testing
NASA Technical Reports Server (NTRS)
Reeder, James R.; Demarco, Kevin; Whitley, Karen S.
2002-01-01
In this paper, the data reduction equations for common delamination toughness tests are rederived for use with specimens which have bonded doublers. The common toughness tests considered here are the double cantilever beam (DCB) for mode I toughness; the end notch flexure (3ENF) and 4 point ENF (4ENF) for mode II toughness; and the mixed mode bending (MMB) test for testing under combined mode I and mode II loading. Because the addition of the doublers changes the bending stiffness of the specimens, these data reduction equations may need to be corrected. Doublers were added to the delamination test specimens to solve a premature failure problem. Delamination toughness is normally tested using a beam with an imbedded insert so that one end of the specimen is split into two arms. If the specimen is too thin, or if the toughness of the material is too high, an arm of the specimen may fail in bending before the delamination grows. When this occurs, the toughness of the material cannot be determined. To delay the bending failure so that delamination growth occurs, doubler plates were bonded to both top and bottom surfaces of the specimen. A doubler parameter, beta, which describes how much the use of doubler plates changed the ratio of full thickness to delaminated bending stiffnesses, was defined. When changes to the data reduction equations were required, the changes were minor when written in terms of the beta parameter. The doubler plate technique was demonstrated by measuring the mixed-mode fracture toughness of a carbon-carbon composite using test specimens which would otherwise have failed before delamination growth occurred. The doubler plate technique may solve several problems that can be encountered when testing delamination fracture toughness.
Overview on Techniques to Construct Tissue Arrays with Special Emphasis on Tissue Microarrays
Vogel, Ulrich
2014-01-01
With the advent of new histopathological staining techniques (histochemistry, immunohistochemistry, in situ hybridization) and the discovery of thousands of new genes, mRNA, and proteins by molecular biology, the need grew for a technique to compare many different cells or tissues on one slide in a cost effective manner and with the possibility to easily track the identity of each specimen: the tissue array (TA). Basically, a TA consists of at least two different specimens per slide. TAs differ in the kind of specimens, the number of specimens installed, the dimension of the specimens, the arrangement of the specimens, the embedding medium, the technique to prepare the specimens to be installed, and the technique to construct the TA itself. A TA can be constructed by arranging the tissue specimens in a mold and subsequently pouring the mold with the embedding medium of choice. In contrast, preformed so-called recipient blocks consisting of the embedding medium of choice have punched, drilled, or poured holes of different diameters and distances in which the cells or tissue biopsies will be deployed manually, semi-automatically, or automatically. The costs of constructing a TA differ from a few to thousands of Euros depending on the technique/equipment used. Remarkably high quality TAs can be also achieved by low cost techniques. PMID:27600339
Structural basis for pulmonary functional imaging.
Itoh, H; Nakatsu, M; Yoxtheimer, L M; Uematsu, H; Ohno, Y; Hatabu, H
2001-03-01
An understanding of fine normal lung morphology is important for effective pulmonary functional imaging. The lung specimens must be inflated. These include (a) unfixed, inflated lung specimen, (b) formaldehyde fixed lung specimen, (c) fixed, inflated dry lung specimen, and (d) histology specimen. Photography, magnified view, radiograph, computed tomography, and histology of these specimens are demonstrated. From a standpoint of diagnostic imaging, the main normal lung structures consist of airways (bronchi and bronchioles), alveoli, pulmonary vessels, secondary pulmonary lobules, and subpleural pulmonary lymphatic channels. This review summarizes fine radiologic normal lung morphology as an aid to effective pulmonary functional imaging.
Development of Protective Coatings for Chromium-Base Alloys
NASA Technical Reports Server (NTRS)
English, J. J.; MacMillan, C. A.; Williams, D. N.; Bartlett, E. S.
1966-01-01
Chromium alloy sheet was clad with 5 to 10-mil-thick oxidation-resistant nickel-base alloy foils. Specimens also contained 1/2 to 1-mil-thick intermediate layers of platinum, tungsten, and/or W-25Re. Cladding was done by the isostatic hot gas-pressure bonding,.process. The clad chromium-alloy specimens were cyclic oxidation tested at 2100 F and 2300 F for up to 200 hours to determine the effectiveness of these metal claddings in protecting the chromium alloy Cr-5W from oxidation and contamination. Cladding systems consisting of 5-mil-thick Ni-20Cr-20W modified with 3 to 5 weight percent aluminum and containing a 1 /2-mil tungsten diffusion barrier demonstrated potential for long-time service at temperatures as high as 2300 F.
Liquid salt environment stress-rupture testing
Ren, Weiju; Holcomb, David E.; Muralidharan, Govindarajan; Wilson, Dane F.
2016-03-22
Disclosed herein are systems, devices and methods for stress-rupture testing selected materials within a high-temperature liquid salt environment. Exemplary testing systems include a load train for holding a test specimen within a heated inert gas vessel. A thermal break included in the load train can thermally insulate a load cell positioned along the load train within the inert gas vessel. The test specimen can include a cylindrical gage portion having an internal void filled with a molten salt during stress-rupture testing. The gage portion can have an inner surface area to volume ratio of greater than 20 to maximize the corrosive effect of the molten salt on the specimen material during testing. Also disclosed are methods of making a salt ingot for placement within the test specimen.
Preliminary Study on Fatigue Strengths of Fretted Ti-48Al-2Cr-2Nb
NASA Technical Reports Server (NTRS)
Miyoshi, Kazuhisa; Lerch, Bradley A.; Draper, Susan L.
2002-01-01
The fatigue behavior (stress-life curve) of gamma titanium aluminide (Ti-48Al-2Cr-2Nb, atomic percent) was examined by conducting two tests: first, a fretting wear test with a fatigue specimen in contact with a typical nickel-based superalloy contact pad in air at temperatures of 296 and 823 K and second, a high-cycle fatigue test of the prefretted Ti-48Al-2Cr-2Nb fatigue specimen at 923 K. Reference high-cycle fatigue tests were also conducted with unfretted Ti-48Al-2Cr-2Nb specimens at 923 K. All Ti-48Al-2Cr-2Nb fatigue specimens were machined from cast slabs. The results indicate that the stress-life results for the fretted Ti-48Al-2Cr-2Nb specimens exhibited a behavior similar to those of the unfretted Ti-48Al-2Cr-2Nb specimens. The values of maximum stress and life for the fretted specimens were almost the same as those for the unfretted specimens. The resultant stress-life curve for the unfretted fatigue specimens was very flat. The flat appearance in the stress-life curve of the unfretted specimens is attributed to the presence of a high density of casting pores. The fatigue strengths of both the fretted and unfretted specimens can be significantly affected by the presence of this porosity, which can decrease the fatigue life of Ti-48Al-2Cr-2Nb. The presence of the porosity made discerning the effect of fretting damage on fatigue strength and life of the specimens difficult.
LaMere, Brandon J; Howell, Renee; Fetterman, Barbara; Shieh, Jen; Castle, Philip E
2008-08-01
The impact of 6-month storage of cervical specimens under alkaline conditions that occurs as the result of Hybrid Capture 2 testing on human papillomavirus (HPV) genotyping is not well documented. To examine this issue, 143 frozen hc2-positive specimens in specimen transport medium were selected at random from each of the following groups: specimens stored for 6 months, 4 months, and 2.5 months under alkaline pH (pH 12-13) and specimens stored 1 month at neutral pH (pH 6-7) as controls. Specimens were tested in a masked fashion for 20 HPV genotypes (HPV6, 11, 16, 18, 26, 31, 33, 35, 39, 45, 51, 52, 53, 56, 58, 59, 66, 68, 73, and 82) using a prototype, research-use-only GP5+/6+ L1 consensus PCR method and multiplex hybridization using Luminex xMAP for detection of specific HPV genotypes One control specimen had missing test results. There were no statistical differences in the number of HPV genotypes detected, number of carcinogenic HPV genotypes detected, or in the signal strength among HPV-positive results across groups. Six-month frozen storage of cervical specimens at alkaline pH had little impact on testing for HPV genotypes among hc2-positive women using this HPV genotyping method.
Bedside hemoglobinometry in hemodialysis patients: lessons from point-of-care testing.
Agarwal, R; Heinz, T
2001-01-01
The HemoCue B-hemoglobin test system (HemoCue, Inc., Mission Viejo, CA) is a photometric method for rapid bedside determination of hemoglobin (Hb). We compared the performance of HemoCue measured Hb against Coulter STK-S (CSTK) measured Hb in chronic hemodialysis (HD) patients in two different settings. In the first setting, Hemocue analysis was performed by multiple HD technicians (n = 132). In the second setting, a nurse trained in proper specimen handling performed the HemoCue analysis (n = 74). Simultaneous measurement of Hb by the CSTK method was performed. First setting: Hb was 11.1+/-1.66 (SD) g/dl by CSTK and 11.7+/-2.29 g/dl by HemoCue. The HemoCue method consistently overestimated Hb by an average (SD) of 0.63 (1.267) g/dl (95% CI = 0.42 to 0.85). Hb was overestimated in 25.7% and underestimated in 2.3% of the patients by 1 g/dl or more. Thus, the HemoCue system was accurate within 1 g/dl only 72% of the time. Second setting: HemoCue overestimated Hb by an average (SD) of 0.29 (0.52) g/dl (95% CI, 0.17 to 0.41). Only 4% of all patients had errors in estimation of 1 g/dl or more. Thus, HemoCue was accurate in 96% of the patients within 1 g/dl. After reviewing the two protocols, the primary difference in the two studies was the technique used to obtain the specimens. When performed properly, Hb testing using the HemoCue testing system had a high level of agreement with CSTK. Appropriate training in specimen handling, as well as test performance, will increase accuracy and reliability of bedside hemoglobinometry.
Thermal barrier coating life prediction model development
NASA Technical Reports Server (NTRS)
Hillery, R. V.; Pilsner, B. H.; Mcknight, R. L.; Cook, T. S.; Hartle, M. S.
1988-01-01
This report describes work performed to determine the predominat modes of degradation of a plasma sprayed thermal barrier coating system and to develop and verify life prediction models accounting for these degradation modes. The primary TBC system consisted of a low pressure plasma sprayed NiCrAlY bond coat, an air plasma sprayed ZrO2-Y2O3 top coat, and a Rene' 80 substrate. The work was divided into 3 technical tasks. The primary failure mode to be addressed was loss of the zirconia layer through spalling. Experiments showed that oxidation of the bond coat is a significant contributor to coating failure. It was evident from the test results that the species of oxide scale initially formed on the bond coat plays a role in coating degradation and failure. It was also shown that elevated temperature creep of the bond coat plays a role in coating failure. An empirical model was developed for predicting the test life of specimens with selected coating, specimen, and test condition variations. In the second task, a coating life prediction model was developed based on the data from Task 1 experiments, results from thermomechanical experiments performed as part of Task 2, and finite element analyses of the TBC system during thermal cycles. The third and final task attempted to verify the validity of the model developed in Task 2. This was done by using the model to predict the test lives of several coating variations and specimen geometries, then comparing these predicted lives to experimentally determined test lives. It was found that the model correctly predicts trends, but that additional refinement is needed to accurately predict coating life.
Nondestructive evaluation of fiber reinforced polymer bridges and decks.
DOT National Transportation Integrated Search
2003-10-01
The research described herein involved both nondestructive evaluation and destructive testing of an FRP honeycomb specimen. The specimen is representative of an FRP bridge that is to be constructed in Troupsburg, New York. The specimen was tested in ...
Shape optimization of shear fracture specimen considering plastic anisotropy
NASA Astrophysics Data System (ADS)
Zhang, S.; Yoon, J. W.; Lee, S.; Lou, Y.
2017-10-01
It is important to fabricate fracture specimens with minimum variation of triaxiality in order to characterize the failure behaviors experimentally. Fracture in ductile materials is usually calibrated by uniaxial tensile, shear and plane strain tests. However, it is often observed that triaxiality for shear specimen changes severely during shear fracture test. The nonlinearity of triaxiality is most critical for shear test. In this study, a simple in-plane shear specimen is optimized by minimizing the variation of stress triaxiality in the shear zone. In the optimization, the Hill48 and Yld2000-2d criteria are employed to model the anisotropic plastic deformation of an aluminum alloy of 6k21. The evolution of the stress triaxiality of the optimized shear specimen is compared with that of the initial design of the shear specimen. The comparison reveals that the stress triaxiality changes much less for the optimized shear specimen than the evolution of the stress triaxiality with the original design of the shear specimen.
The width-tapered double cantilever beam for interlaminar fracture testing
NASA Technical Reports Server (NTRS)
Bascom, W. D.; Jensen, R. M.; Bullman, G. W.; Hunston, D. L.
1984-01-01
The width-tapered double-cantilever-beam (WTDCB) specimen configuration used to determine the Mode-I interlaminar fracture energy (IFE) of composites has special advantages for routine development work and for quality-assurance purposes. These advantages come primarily from the simplicity of testing and the fact that the specimen is designed for constant change in compliance with crack length, so that the computation of Mode-I IFE is independent of crack length. In this paper, a simplified technique for fabrication and testing WTDCB specimens is described. Also presented are the effects of fiber orientation and specimen dimensions, a comparison of data obtained using the WTDCB specimens and other specimen geometries, and comparison of data obtained at different laboratories. It is concluded that the WTDCB gives interlaminar Mode-I IFE essentially equal to other type specimens, and that it can be used for rapid screening in resin-development work and for quality assurance of composite materials.
Henriques, B; Gonçalves, S; Soares, D; Silva, F S
2012-09-01
The aim of this study was to evaluate the effect of thermo-mechanical cycling on the metal-ceramic bond strength of conventional porcelain fused to metal restorations (PFM) and new functionally graded metal-ceramic dental restorations (FGMR). Two types of specimens were produced: PFM and FGMR specimens. PFM specimens were produced by conventional PFM technique. FGMR specimens were hot pressed and prepared with a metal/ceramic composite interlayer (50 M, vol%) at the metal-ceramic interface. They were manufactured and standardized in cylindrical format and then submitted to thermal (3000, 6000 and 12,000 cycles; between 5 °C and 60 °C; dwell time: 30s) and mechanical (25,000, 50,000 and 100,000 cycles under a load of 50 N; 1.6 Hz) cycling. The shear bond strength tests were performed in a universal testing machine (crosshead speed: 0.5mm/min), using a special device to concentrate the tension at the metal-ceramic interface and the load was applied until fracture. The metal-ceramic interfaces were examined with SEM/EDS prior to and after shear tests. The Young's modulus and hardness were measured across the interfaces of both types of specimens using nanoindentation tests. Data was analyzed with Shapiro-Wilk test to test the assumption of normality. The 2-way ANOVA was used to compare shear bond strength results (p<0.05). FGMR specimens showed significantly (p<0.001) higher shear bond strength results than PFM specimens, irrespective of fatigue conditions. Fatigue conditions significantly (p<0.05) affected the shear bond strength results. The analysis of surface fracture revealed adhesive fracture type for PFM specimens and mixed fracture type for FGMR specimens. Nanoindentation tests showed differences in mechanical properties measured across the metal-ceramic interface for the two types of specimens, namely Young's Modulus and hardness. This study showed significantly better performance of the new functionally graded restorations relative to conventional PFM restorations, under fatigue testing conditions and for the materials tested. Copyright © 2012 Elsevier Ltd. All rights reserved.
A preliminary investigation of acousto-ultrasonic NDE of metal matrix composite test specimens
NASA Technical Reports Server (NTRS)
Kautz, Harold E.; Lerch, Brad A.
1991-01-01
Acousto-ultrasonic (AU) measurements were performed on a series of tensile specimens composed of 8 laminated layers of continuous, SiC fiber reinforced Ti-15-3 matrix. The following subject areas are covered: AU signal analysis; tensile behavior; AU and interrupted tensile tests; AU and thermally cycled specimens; AU and stiffness; and AU and specimen geometry.
Fatigue Lives Of Laser-Cut Metals
NASA Technical Reports Server (NTRS)
Martin, Michael R.
1988-01-01
Fatigue lives made to approach those attainable by traditional grinding methods. Fatigue-test specimens prepared from four metallic alloys, and material removed from specimens by manual grinding, by Nd:glass laser, and by Nd:YAG laser. Results of fatigue tests of all specimens indicated reduction of fatigue strengths of laser-fired specimens. Laser machining holds promise for improved balancing of components of gas turbines.
Collins, Laura C; Marotti, Jonathan D; Baer, Heather J; Tamimi, Rulla M
2008-02-06
We compared estrogen receptor (ER) assay results abstracted from pathology reports with ER results determined on the same specimens by a central laboratory with an immunohistochemical assay. Paraffin sections were cut from tissue microarrays containing 3093 breast cancer specimens from women enrolled in the Nurses' Health Study, 1851 of which had both pathology reports and tissue available for central laboratory testing. All sections were immunostained for ER at the same time. The original assays were biochemical for 1512 (81.7%) of the 1851 specimens, immunohistochemical for 336 (18.2%), and immunofluorescent for three (0.2%). ER results from pathology reports and repeat central laboratory testing were in agreement for 87.3% of specimens (1615 of the 1851 specimens; kappa statistic = 0.64, P < .001). When the comparison was restricted to the specimens for which the ER assays were originally performed by immunohistochemistry, the agreement rate increased to 92.3% of specimens (310 of the 336 specimens; kappa statistic = 0.78, P < .001). Thus, ER assay results from pathology reports appear to be a reasonable alternative to central laboratory ER testing for large, population-based studies of patients with breast cancer.
A comparative evaluation of in-plane shear test methods for laminated graphite-epoxy composites
NASA Technical Reports Server (NTRS)
Morton, John; Ho, Henjen
1992-01-01
The objectives were to evaluate popular shear test methods for various forms of graphite-epoxy composite materials and to determine the shear response of graphite-epoxy composites with various forms of fiber architecture. Numerical and full-field experimental stress analyses were performed on four shear test configurations for unidirectional and bidirectional graphite-epoxy laminates to assess the uniformity and purity of the shear stress (strain) fields produced in the specimen test section and to determine the material in-plane shear modulus and shear response. The test methods were the 10 deg off-axis, the +/- 45 deg tension, the Iosipescu V-notch, and a compact U-notch specimen. Specimens were prepared from AS4/3501-6 graphite-epoxy panels, instrumented with conventional strain gage rosettes and with a cross-line moire grating, and loaded in a convenient testing machine. The shear responses obtained for each test method and the two methods of specimen instrumentation were compared. In a second phase of the program the shear responses obtained from Iosipescu V-notch beam specimens were determined for woven fabric geometries of different weave and fiber architectures. Again the responses of specimens obtained from strain gage rosettes and moire interferometry were compared. Additional experiments were performed on a bidirectional cruciform specimen which was also instrumented with strain gages and a moire grating.
Compressive evaluation of homogeneous and graded epoxy-glass particulate composites.
Seaglar, J; Rousseau, C-E
2015-04-01
The propagation of stress waves in epoxy-glass particulate composites and graded materials was studied experimentally. Materials tested in this study consisted of an epoxy matrix with various concentrations of spherical glass particles having a mean diameter of 42μm. Plate impact experiments were performed using a gas gun. Embedded within the specimens were manganin stress gauges used to record propagating compressive longitudinal stress waves through the material. High strain rate experiments using a Split Hopkinson Pressure Bar (SHPB) apparatus were also performed to evaluate the dynamic strength of the specimens, while quasi-static compression tests were undertaken to characterize their quasi-static behavior. Ultrasonic wave speed measurements were carried-out in order to obtain additional material properties and characterize the gradation in functionally graded materials (FGM). It was found that low volume fractions of particles are detrimental to the performance of the material under impact loading, while concentrations in the range of about 30 to 45% by volume exhibit characteristics of higher degrees of scattering. This suggests that materials in this latter range would be more effective in the thwarting of destructive shock waves than the homogeneous matrix material. Impact testing of FGM specimens suggests that impact loading on the stiff (high volume fraction) face results in much higher levels of scattering. Therefore, such materials would be effective for use in light weight armor or as shielding materials due to their effective attenuation of mechanical impulses. Copyright © 2015 Elsevier B.V. All rights reserved.
Development of a New Rain Erosion Test Method
NASA Astrophysics Data System (ADS)
Chung, Dong-Teak; Kang, Hyung; Jin, Doo-Han
The nose of a missile, flying through raining region with a supersonic speed, is subjected to the rain erosion because the nose is made of a brittle ceramic material. Various test methods are used to address such a phenomenon. However, most of the methods are expensive and/or require complicated facilities. The simple yet very effective rain erosion test method is developed. It consists of (1) a low pressure air gun, (2) a sabot assembly for launching single rain drop, (3) a stopper, and (4) a specimen holder block. The sabot assembly similar to the hypodermic syringe carries specific amount of water toward the stopper launched by the low pressure air gun. When the impact occurs against the stopper which stops the sabot, the water and the steel plunger (at the back of the sabot) continues pushing the sabot to generate a high pressure in the chamber filled with resilient silicon rubber. The pressurized silicon rubber then is squeezed through the small opening in front of the sabot, thus, accelerates the water droplet to a much higher velocity. The velocity of the droplet is measured by the make-screen method, where there are two aluminum foils with an insulating layer in between. The droplet velocity up to 800 m/s is successfully attained using a low pressure air compressor. The specimen made of a ceramic material is placed in front of the high speed water droplet and the rain erosion damage on the surface of the specimen is observed.
NASA Astrophysics Data System (ADS)
Xu, Yibiao; Li, Yawei; Yang, Jianhong; Sang, Shaobai; Wang, Qinghu
2017-06-01
The application of ledge-free sidewalls in the Hall-Héroult cells can potentially reduce the energy requirement of aluminum production by about 30 pct (Nightingale et al. in J Eur Ceram, 33:2761-2765, 2013). However, this approach poses great material challenges since such sidewalls are in direct contact with corrosive electrolyte. In the present paper, (Ni,Mg)(Al,Fe)2O4 materials were prepared using fused magnesia, reactive alumina, nickel oxide, and iron oxide powders as the starting materials. The sintering behaviors of specimens as well as their corrosion resistance to molten electrolyte have been investigated by means of X-ray diffraction and scanning electron microscope. The results show that after firing at temperature ranging from 1673 K (1400 °C) up to 1873 K (1600 °C), all the specimens prepared are composed of single-phase (Ni,Mg)(Al,Fe)2O4 composite spinel, the lattice parameter of which increases with increasing Fe3+ ion concentration. Increasing the iron oxide content enhances densification of the specimens, which is accompanied by the formation of homogeneously distributed smaller pores in the matrix. The corrosion tests show that corrosion layers consist of fluoride and Ni(Al,Fe)2O4 composite spinel grains are produced in specimens with Fe/Al mole ratio no more than 1, whereas dense Ni(Al,Fe)2O4 composite spinel layers are formed on the surface of the specimens with Fe/Al mole ratio more than 1. The dense Ni(Al,Fe)2O4 composite spinel layers formed improve the corrosion resistance of the specimens by inhibiting the infiltration of electrolyte and hindering the chemical reaction between the specimen and electrolyte.
MICROSTRUCTURAL AND MECHANICAL CHARACTERIZATION OF 2-D AND 3-D SiC/SiNC CERAMIC MATRIX COMPOSITES
2018-02-23
48 5.2 Residual Strength of Test Specimens Reaching Run -Out ...........................................48 5.3 Fracture...46 Table 10. Residual Strength Tension Test Results for Creep Rupture Specimens Reaching Run - Out...Residual Strength Tension Test Results for Fatigue Specimens Reaching Run -Out . 49 vii Distribution Statement A. Approved for public release
Crack Initiation and Growth Behavior at Corrosion Pit in 2024-T3 Aluminum Alloy
2014-09-01
63 Figure B.1: The crack length vs. number of cycles during fatigue testing for the 2AI-01 specimen...number of cycles during fatigue testing for the the 2AI- 02 specimen...64 Figure B.3: The crack length vs. number of cycles during fatigue testing for the 2Sl-01 specimen
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weidenaar, W.A.
1992-12-01
Centrally notched (hole), cross-ply, ((0/90) sub 2) sub s, and unidirectional, (0) sub 8 laminates of Silicon Carbide fiber-reinforced Aluminosilicate glass, SiC/1723, were fatigue tested under tension-compression loading with a load ratio of -1. Damage accumulated continuously for both lay-ups, leading to eventual failure and a reduced fatigue life. Critical damage in the cross-ply consisted of longitudinal cracks in the 90 deg plies growing and combining with transverse cracks to effectively eliminate the 90 deg plies' load carrying capability and allowing the specimen to buckle. Critical damage in the unidirectional lay-up consisted of longitudinal cracks which initiated at the shearmore » stress concentration points on the hole periphery. Reversed cyclic loading caused continued crack growth at maximum stresses below the tension-tension fatigue limit. The cross-ply lay-up appeared insensitive to the hole, while critical damage in the unidirectional lay-up was dependent on the shear stress concentrations at the hole.... Ceramic matrix composite, Tension-compression fatigue, Notched specimen.« less
Environmental Assisted Cracking in High Hardness Armor Steel
1985-09-01
Longitudinal and transverse tension tests (ASTM E8-81) utilizing flat dogbane specimens, and subsize Charpy impact tests (ASTM 23-81) were performed on part...had been obtained. Longitudinal and transverse tension tests (ASTM E8-81) utilizing flat dogbane specimens, and subsize Charpy impact tests (ASTM 23... Charpy and tensile bar surfaces. All of the optical metallography samples were prepared using standard metallographic practices. The optical specimens
Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens
Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš
2018-01-01
Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified. PMID:29337867
Contact thermal shock test of ceramics
NASA Technical Reports Server (NTRS)
Rogers, W. P.; Emery, A. F.
1992-01-01
A novel quantitative thermal shock test of ceramics is described. The technique employs contact between a metal-cooling rod and hot disk-shaped specimen. In contrast with traditional techniques, the well-defined thermal boundary condition allows for accurate analyses of heat transfer, stress, and fracture. Uniform equibiaxial tensile stresses are induced in the center of the test specimen. Transient specimen temperature and acoustic emission are monitored continuously during the thermal stress cycle. The technique is demonstrated with soda-lime glass specimens. Experimental results are compared with theoretical predictions based on a finite-element method thermal stress analysis combined with a statistical model of fracture. Material strength parameters are determined using concentric ring flexure tests. Good agreement is found between experimental results and theoretical predictions of failure probability as a function of time and initial specimen temperature.
Replacement/Refurbishment of JSC/NASA POD Specimens
NASA Technical Reports Server (NTRS)
Castner, Willard L.
2010-01-01
The NASA Special NDE certification process requires demonstration of NDE capability by test per NASA-STD-5009. This test is performed with fatigue cracked specimens containing very small cracks. The certification test results are usually based on binomial statistics and must meet a 90/95 Probability of Detection (POD). The assumption is that fatigue cracks are tightly closed, difficult to detect, and inspectors and processes passing such a test are well qualified for inspecting NASA fracture critical hardware. The JSC NDE laboratory has what may be the largest inventory that exists of such fatigue cracked NDE demonstration specimens. These specimens were produced by the hundreds in the late 1980s and early 1990s. None have been produced since that time and the condition and usability of the specimens are questionable.
CompareTests is an R package to estimate agreement and diagnostic accuracy statistics for two diagnostic tests when one is conducted on only a subsample of specimens. A standard test is observed on all specimens.
Van Der Pol, Barbara; Martin, David H.; Schachter, Julius; Quinn, Thomas C.; Gaydos, Charlotte A.; Jones, Robert B.; Crotchfelt, Kimberly; Moncada, Jeanne; Jungkind, D.; Turner, Buffy; Peyton, Cynthia; Kelly, James F.; Weiss, Judith B.; Rosenstraus, Maurice
2001-01-01
The COBAS AMPLICOR CT/NG test for Neisseria gonorrhoeae cross-reacts with certain strains of nonpathogenic Neisseria species. In some strains, the target sequence is identical to that of N. gonorrhoeae, whereas other strains have a small number of mismatches within the regions recognized by the primers or probe used in the COBAS AMPLICOR NG test. These cross-reactive strains are occasionally present in urogenital specimens, causing false-positive results in the COBAS AMPLICOR NG test. Analysis of the data generated in a large multicenter clinical trial showed that 2.9% of the specimens gave signals between A660s of 0.2 and 3.5 but that one-half of these equivocal specimens did not contain N. gonorrhoeae. Most of these equivocal specimens were correctly classified as true positive or true negative by retesting in duplicate and defining a PCR-positive result as two of three results with an A660 of ≥2.0. If specimens had been classified as positive or negative based on a single test result using a cutoff of an A660 of 0.2, specificity would have ranged from 96.2 to 98.9% depending on specimen type, sex, and presence of symptoms. By employing the equivocal zone-retesting algorithm, specificity increased to 98.6 to 99.9% with little effect (0.1 to 4.9% decrease) on sensitivity in most specimen types, enabling the test to achieve a positive predictive value of at least 90% in populations with a prevalence of 4% or higher. In lower-prevalence populations, the test could be used to screen for presumptive infections that would have to be confirmed by an independent test. PMID:11526134
An improved correlation procedure for subsize and full-size Charpy impact specimen data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sokolov, M.A.; Alexander, D.J.
1997-03-01
The possibility of using subsize specimens to monitor the properties of reactor pressure vessel steels is receiving increasing attention for light-water reactor plant life extension. This potential results from the possibility of cutting samples of small volume form the internal surface of the pressure vessel for determination of the actual properties of the operating pressure vessel. In addition, plant life extension will require supplemental data that cannot be provided by existing surveillance programs. Testing of subsize specimens manufactured from broken halves of previously tested surveillance Charpy specimens offers an attractive means of extending existing surveillance programs. Using subsize Charpy V-notch-typemore » specimens requires the establishment of a specimen geometry that is adequate to obtain a ductile-to-brittle transition curve similar to that obtained from full-size specimens, and the development of correlations for transition temperature and upper-shelf energy (USE) level between subsize and full-size specimens. Five different geometries of subsize specimens were selected for testing and evaluation. The specimens were made from several types of pressure vessel steels with a wide range of yield strengths, transition temperatures, and USEs. The effects of specimen dimensions, including notch depth, angle, and radius, have been studied. The correlations of transition temperatures determined from different types of subsize specimens and the full-size specimens are presented. A new procedure for transforming data from subsize specimens is developed. The transformed data are in good agreement with data from full-size specimens for materials that have USE levels less than 200 J.« less
Fuller, Maren Y; Mody, Dina; Hull, April; Pepper, Kristi; Hendrickson, Heather; Olsen, Randall
2018-02-01
- Thyroid nodules have a prevalence of approximately 70% in adults. Fine-needle aspiration (FNA) is a minimally invasive, cost-effective, standard method to collect tissue from thyroid nodules for cytologic examination. However, approximately 15% of thyroid FNA specimens cannot be unambiguously diagnosed as benign or malignant. - To investigate whether clinically actionable data can be obtained using next-generation sequencing of residual needle rinse material. - A total of 24 residual needle rinse specimens with malignant (n = 6), indeterminate (n = 9), or benign (n = 9) thyroid FNA diagnoses were analyzed in our clinical molecular diagnostics laboratory using next-generation sequencing assays designed to detect gene mutations and translocations that commonly occur in thyroid cancer. Results were correlated with surgical diagnoses and clinical outcomes. - Interpretable data were generated from 23 of 24 residual needle rinse specimens. Consistent with its well-known role in thyroid malignancy, BRAF V600E mutations were detected in 4 malignant cases. An NRAS mutation was detected in 1 benign case. No mutations were detected from specimens with indeterminate diagnoses. - Our data demonstrate that residual thyroid FNA needle rinses are an adequate source of material for molecular diagnostic testing. Importantly, detection of a mutation implicated in thyroid malignancy was predictive of the final surgical diagnosis and clinical outcome. Our strategy to triage thyroid nodules with indeterminate cytology with molecular testing eliminates the need to perform additional FNA passes into dedicated media or to schedule additional invasive procedures. Further investigation with a larger sample size to confirm the clinical utility of our proposed strategy is underway.
NASA Technical Reports Server (NTRS)
Hribar, V. F.; Bauer, J. L.; O'Donnell, T. P.
1986-01-01
Five black electrically conductive thermal-control coatings have been formulated and tested for application on the Galileo spacecraft. The coatings consisted of organic and inorganic systems applied on titanium and aluminum surfaces. The coatings were tested under simulated space environment conditions. Coated specimens were subjected to thermal radiation and convective and conductive heating from -196 to 538 C. Mechanical, physical, thermal, electrical, and optical characteristics, formulation, mixing, application, surface preparation of substrates, and a method of determining electrical resistance are presented for the silicone matrix formulation designated as GF-580.
Development of a model for occipital fixation--validation of an analogue bone material.
Mullett, H; O'Donnell, T; Felle, P; O'Rourke, K; FitzPatrick, D
2002-01-01
Several implant systems may be used to fuse the skull to the upper cervical spine (occipitocervical fusion). Current biomechanical evaluation is restricted by the limitations of human cadaveric specimens. This paper describes the design and validation of a synthetic testing model of the occipital bone. Data from thickness measurement and pull-out strength testing of a series of human cadaveric skulls was used in the design of a high-density rigid polyurethane foam model. The synthetic occipital model demonstrated repeatable and consistent morphological and biomechanical properties. The model provides a standardized environment for evaluation of occipital implants.
Solid State Power Controller Fuse Development Program.
1983-10-01
4NYP Appendix A nic =,-, ’XW LX, nII4CD1AFam" CC,’AP44 257-290 TABLE I - FAULT CURRENT TRIP TJMWS Fa’ Ii AC Volts Seconds Rema:ks 1. 1.6 100Z 234.0 417.0...calibration date: 12 July 1983 Biddle Power Rheostat, 1000 W, Cat. No. 20 4.2 Procedure Testing was accomplished in two lots, one consisting of the SPC-2A and...Last calibration date: 12 July 1983 Biddle 100dW Power Rheostat, Cat. No. 20 Variac, Environ No. 380-503 4.2 Procedure The test specimens were suspended
Cheung, Yun-Chung; Juan, Yu-Hsiang; Ueng, Shir-Hwa; Lo, Yung-Feng; Huang, Pei-Chin; Lin, Yu-Ching; Chen, Shin-Cheh
2015-10-01
Presence of microcalcifications within the specimens frequently signifies a successful attempt of stereotactic vacuum-assisted breast biopsy (VABB) in obtaining a pathologic diagnosis of the breast microcalcifications. In this study, the authors aimed to assess and compare the accuracy and consistency of calcified or noncalcified specimens obtained from same sites of sampling on isolated microcalcifications without mass in diagnosing high-risk and malignant lesions. To the best of our knowledge, an individual case-based prospective comparison has not been reported.With the approval from institutional review board of our hospital (Chang Gung Memorial Hospital), the authors retrospectively reviewed all clinical cases of stereotactic VABBs on isolated breast microcalcifications without mass from our database. The authors included those having either surgery performed or had clinical follow-up of at least 3 years for analysis. All the obtained specimens with or without calcification were identified using specimen radiographs and separately submitted for pathologic evaluation. The concordance of diagnosis was assessed for both atypia and malignant lesions.A total of 390 stereotactic VABB procedures (1206 calcified and 1456 noncalcified specimens) were collected and reviewed. The consistent rates between calcified and noncalcified specimens were low for atypia and malignant microcalcifications (44.44% in flat epithelial atypia, 46.51% in atypical ductal hyperplasia, 55.73% in ductal carcinoma in situ, and 71.42% in invasive ductal carcinoma). The discordance in VABB diagnoses indicated that 41.33% of malignant lesions would be misdiagnosed by noncalcified specimens. Furthermore, calcified specimens showed higher diagnostic accuracy of breast cancer as compared with the noncalcified specimens (91.54 % versus 69.49%, respectively). The evaluation of both noncalcified specimens and calcified specimens did not show improvement of diagnostic accuracy as compared with evaluating calcified specimens alone (91.54% versus 91.54%, respectively).The high prevalence of diagnostic discordance between the calcified and noncalcified specimens indicated the higher value of calcified specimens in diagnosing atypia and malignant microcalcifications. Noncalcified specimens did not provide additional diagnostic benefit from this study. The separation of calcified and noncalcified specimens may facilitate more focused interpretation from pathologists among the large number of specimens.
Anderson, Steven; Bloom, Kenneth J; Vallera, Dino U; Rueschoff, Josef; Meldrum, Cliff; Schilling, Robert; Kovach, Barbara; Lee, Ju Ruey-Jiuan; Ochoa, Pam; Langland, Rachel; Halait, Harkanwal; Lawrence, H Jeffrey; Dugan, Michael C
2012-11-01
A polymerase chain reaction-based companion diagnostic (cobas 4800 BRAF V600 Mutation Test) was recently approved by the US Food and Drug Administration to select patients with BRAF-mutant metastatic melanoma for treatment with the BRAF inhibitor vemurafenib. (1) To compare the analytic performance of the cobas test to Sanger sequencing by using screening specimens from phase II and phase III trials of vemurafenib, and (2) to assess the reproducibility of the cobas test at different testing sites. Specimens from 477 patients were used to determine positive and negative percent agreements between the cobas test and Sanger sequencing for detecting V600E (1799T>A) mutations. Specimens were evaluated with a massively parallel pyrosequencing method (454) to resolve discordances between polymerase chain reaction and Sanger results. Reproducibility of the cobas test was assessed at 3 sites by using 3 reagent lots and an 8-member panel of melanoma samples. A valid cobas result was obtained for all eligible patients. Sanger sequencing had a failure rate of 9.2% (44 of 477). For the remaining 433 specimens, positive percent agreement was 96.4% (215 of 223) and negative percent agreement, 80% (168 of 210). Among 42 cobas mutation-positive/Sanger V600E-negative specimens, 17 were V600E positive and 24 were V600K positive by 454. The cobas test detected 70% of V600K mutations. In the reproducibility study, a correct interpretation was made for 100% of wild-type specimens and specimens with greater than 5% mutant alleles; V600E mutations were detected in 90% of specimens with less than 5% mutant alleles. The cobas test (1) had a lower assay failure rate than that of Sanger, (2) was more sensitive in detecting V600E mutations, (3) detected most V600K mutations, and (4) was highly reproducible.
Layered Plating Specimens For Mechanical Tests
NASA Technical Reports Server (NTRS)
Thompson, Linda B.; Flowers, Cecil E.
1991-01-01
Layered specimens readily made in standard sizes for tensile and other tests of mechanical properties. Standard specimen of metal ordinarily difficult to plate to standard grip thickness or diameter made by augmentation with easier-to-plate material followed by machining to standard size and shape.
21 CFR 58.195 - Retention of records.
Code of Federal Regulations, 2010 CFR
2010-04-01
... specimens (except those specimens obtained from mutagenicity tests and wet specimens of blood, urine, feces, and biological fluids), samples of test or control articles, and specially prepared material, which are relatively fragile and differ markedly in stability and quality during storage, shall be retained...
Unger, Stefan; Stefan, Unger; Blauth, Michael; Michael, Blauth; Schmoelz, Werner; Werner, Schmoelz
2010-12-01
In the development of new strategies for fracture fixation, new methods have to be tested biomechanically under in vitro conditions before clinical trials can be performed. The gold standard for laboratory evaluations is fresh-frozen specimen. As the availability of fresh-frozen specimens is limited and since their use bears infectious risks, specimens treated with various chemical embalming fluids are also used. These preservation methods may alter the mechanical properties of the specimens used. Therefore, the aims of the present study were to determine the effects of three different preservation methods (formalin fixation (FO), Thiel-fixation (TH), and alcohol-glycerine fixation (AG)) on the elastic and postyield mechanical properties of cortical bone and to compare these properties to those of fresh-frozen (FF) specimens. Cylindrical cortical specimens (diameter 3mm, length 60 mm) were obtained from human femurs (n=48) and bovine tibiae (n=40). Before specimen immersion in different fixation fluids, bone mineral density (BMD) as well as the initial Young's modulus was determined. The Young's modulus was determined in a nondestructive bending test, and measurements were repeated after 6 months of immersion in fixative solution. Subsequent to the nondestructive test, a destructive 3-point bending test was conducted to assess the postyield and fracture properties. The BMD as well as the initial Young's modulus showed no significant differences between the four test groups. After 6 months in fixative solution, the Young's modulus was significantly lowered in human Thiel specimens and only showed minor changes in formalin- and alcohol-glycerine-treated specimens. The plastic energy absorption of human and bovine specimens was altered significantly. Formalin as well as alcohol-glycerine fixation yielded a significant decrease in plastic energy absorption, whereas Thiel fixation significantly increased the plastic energy absorption. Because of the significantly altered plastic mechanical properties of cortical bone, the use fresh-frozen bone specimens is recommended in biomechanical studies investigating failure loads of orthopaedic implants. The use of embalmed specimens should be restricted to pilot tests. Copyright © 2010 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Domack, M. S.
1985-01-01
A research program was conducted to critically assess the effects of precracked specimen configuration, stress intensity solutions, compliance relationships and other experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate. Modified compact and double beam wedge-loaded specimens were tested and analyzed to determine the threshold stress intensity factor and stress corrosion crack growth rate. Stress intensity solutions and experimentally determined compliance relationships were developed and compared with other solutions available in the literature. Crack growth data suggests that more effective crack length measurement techniques are necessary to better characterize stress corrosion crack growth. Final load determined by specimen reloading and by compliance did not correlate well, and was considered a major source of interlaboratory variability. Test duration must be determined systematically, accounting for crack length measurement resolution, time for crack arrest, and experimental interferences. This work was conducted as part of a round robin program sponsored by ASTM committees G1.06 and E24.04 to develop a standard test method for stress corrosion testing using precracked specimens.
Compatibility of an FeCrAl alloy with flowing Pb-Li in a thermal convection loop
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pawel, Steven J.; Unocic, Kinga A.
A mono-metallic thermal convection loop (TCL) fabricated from alloy APMT (Fe21Cr5Al3Mo) tubing and filled with 0.025 m long tensile specimens of the same alloy was operated continuously for 1000 h with commercially pure Pb-17 at.%Li (Pb-Li) at a peak temperature of 550 ± 1.5 °C and a temperature gradient of ~116 °C. The resulting Pb-Li flow rate was ~0.0067 m/s. A 1050 °C pre-oxidation treatment (to form an external alumina scale) given to most specimens exposed within the TCL decreased total mass loss by a factor of 3–30 compared to adjacent specimens that were not pre-oxidized. However, all specimens exposedmore » above 500 °C lost mass suggesting that the alumina scale was not entirely stable in flowing Pb-Li at these temperatures. Post-exposure room temperature tensile tests indicated that the mechanical properties of APMT were substantially influenced by extended exposures in the range of 435–490 °C, which caused an increase in yield strength (~65%) and a corresponding decrease in ductility associated with α' embrittlement. Specimens annealed in argon at the same temperature exhibited identical changes without exposure to Pb-Li. In conclusion, scanning transmission electron microscopy revealed Cr-clusters within the microstructure in specimens exposed in the low temperature regions (<490 °C) of the TCL, indicating the formation of α' consistent with the mechanism of α' embrittlement.« less
Compatibility of an FeCrAl alloy with flowing Pb-Li in a thermal convection loop
Pawel, Steven J.; Unocic, Kinga A.
2017-08-01
A mono-metallic thermal convection loop (TCL) fabricated from alloy APMT (Fe21Cr5Al3Mo) tubing and filled with 0.025 m long tensile specimens of the same alloy was operated continuously for 1000 h with commercially pure Pb-17 at.%Li (Pb-Li) at a peak temperature of 550 ± 1.5 °C and a temperature gradient of ~116 °C. The resulting Pb-Li flow rate was ~0.0067 m/s. A 1050 °C pre-oxidation treatment (to form an external alumina scale) given to most specimens exposed within the TCL decreased total mass loss by a factor of 3–30 compared to adjacent specimens that were not pre-oxidized. However, all specimens exposedmore » above 500 °C lost mass suggesting that the alumina scale was not entirely stable in flowing Pb-Li at these temperatures. Post-exposure room temperature tensile tests indicated that the mechanical properties of APMT were substantially influenced by extended exposures in the range of 435–490 °C, which caused an increase in yield strength (~65%) and a corresponding decrease in ductility associated with α' embrittlement. Specimens annealed in argon at the same temperature exhibited identical changes without exposure to Pb-Li. In conclusion, scanning transmission electron microscopy revealed Cr-clusters within the microstructure in specimens exposed in the low temperature regions (<490 °C) of the TCL, indicating the formation of α' consistent with the mechanism of α' embrittlement.« less
NASA Astrophysics Data System (ADS)
Harris, David Lee
The objective of the research is to characterize the behavior of composite/composite joints with paste adhesive using both experimental testing and analytical modeling. In comparison with the conventional tape adhesive, joining composites using paste adhesive provides several advantages. The carbon fiber laminate material systems employed in this study included IM7 carbon fibers and 977-3 epoxy matrix assembled in prepreg tape, and AS4 carbon fibers and 977-3 epoxy matrix as a five-harness satin weave. The adhesive employed was EA 9394 epoxy. All laminates and test specimens were fabricated and inspected by Boeing using their standard propriety procedures. Three types of test specimens were used in the program. They were bonded double-lap shear (DLS), bonded double cantilever beam (DCB) and bonded interlaminar tension (ILT) specimens. A group of specimens were conditioned at elevated temperature and humidity in an environmental chamber at Boeing's facility and their moisture absorption recorded with time. Specimens were tested at room temperature dry and elevated temperatures. DCB and DLS specimens were tested in fatigue as well as static conditions. Two-dimensional finite element models of the three configurations were developed for determining stresses and strains using the ABAQUS finite element package code. Due to symmetry, only the one-half of the specimen needed to be considered thus reducing computational time. The effect of the test fixture is not taken into account instead equivalent distributed stresses are applied directly on the composite laminates. For each of the specimen, the distribution of Mises stress and the first strain invariant J1 are obtained to identify potential failure locations within a specimen.
Baseline tensile tests of composite materials for LDEF (Long Duration Exposure Facility) exposure
NASA Technical Reports Server (NTRS)
Witte, William G.
1987-01-01
Tensile specimens of five graphite fiber reinforced composite materials were tested at room temperature to provide baseline data for similar specimens exposed to the space environment in low-Earth orbit on the NASA Long Duration Exposure Facility. All specimens were 4-ply (+ or - 45 deg)s layups; at least five replicate specimens were tested for each parameter evaluated. Three epoxy-matrix materials and two polysulfone-matrix materials, several fiber volume fractions, and two sizes of specimen were evaluated. Stress-strain and Poisson's ratio-stress curves, ultimate stress, strain at failure, secant modulus at 0.004 strain, inplane shear stress-strain curves, and unidirectional shear modulus at .004 shear strain are presented.
AGC-2 Specimen Post Irradiation Data Package Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Windes, William Enoch; Swank, W. David; Rohrbaugh, David T.
This report documents results of the post-irradiation examination material property testing of the creep, control, and piggyback specimens from the irradiation creep capsule Advanced Graphite Creep (AGC)-2 are reported. This is the second of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades. The AGC-2 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 600°C and to a peak dose of 5 dpa (displacements per atom). One-half of the creep specimens weremore » subjected to mechanical stresses (an applied stress of either 13.8, 17.2, or 20.7 MPa) to induce irradiation creep. All post-irradiation testing and measurement results are reported with the exception of the irradiation mechanical strength testing, which is the last destructive testing stage of the irradiation testing program. Material property tests were conducted on specimens from 15 nuclear graphite grades using a similar loading configuration as the first AGC capsule (AGC-1) to provide easy comparison between the two capsules. However, AGC-2 contained an increased number of specimens (i.e., 487 total specimens irradiated) and replaced specimens of the minor grade 2020 with the newer grade 2114. The data reported include specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and volume data necessary to derive density, elastic constants (Young’s modulus, shear modulus, and Poisson’s ratio) from ultrasonic time-of-flight velocity measurements, Young’s modulus from the fundamental frequency of vibration, electrical resistivity, and thermal diffusivity and thermal expansion data from 100–500°C. No data outliers were determined after all measurements were completed. A brief statistical analysis was performed on the irradiated data and a limited comparison between pre- and post-irradiation properties is presented. A more complete evaluation of trends in the material property changes, as well as irradiation-induced creep due to irradiation, temperature, and applied load on specimens will be discussed in later AGC-2 post-irradiation examination analysis reports.« less
Design, analysis, and test verification of advanced encapsulation systems
NASA Technical Reports Server (NTRS)
Mardesich, N.; Minning, C.
1982-01-01
Design sensitivities are established for the development of photovoltaic module criteria and the definition of needed research tasks. The program consists of three phases. In Phase I, analytical models were developed to perform optical, thermal, electrical, and structural analyses on candidate encapsulation systems. From these analyses several candidate systems will be selected for qualification testing during Phase II. Additionally, during Phase II, test specimens of various types will be constructed and tested to determine the validity of the analysis methodology developed in Phase I. In Phse III, a finalized optimum design based on knowledge gained in Phase I and II will be developed. All verification testing was completed during this period. Preliminary results and observations are discussed. Descriptions of the thermal, thermal structural, and structural deflection test setups are included.
An electromechanical material testing system for in situ electron microscopy and applications.
Zhu, Yong; Espinosa, Horacio D
2005-10-11
We report the development of a material testing system for in situ electron microscopy (EM) mechanical testing of nanostructures. The testing system consists of an actuator and a load sensor fabricated by means of surface micromachining. This previously undescribed nanoscale material testing system makes possible continuous observation of the specimen deformation and failure with subnanometer resolution, while simultaneously measuring the applied load electronically with nanonewton resolution. This achievement was made possible by the integration of electromechanical and thermomechanical components based on microelectromechanical system technology. The system capabilities are demonstrated by the in situ EM testing of free-standing polysilicon films, metallic nanowires, and carbon nanotubes. In particular, a previously undescribed real-time instrumented in situ transmission EM observation of carbon nanotubes failure under tensile load is presented here.
Hydraulic Fatigue-Testing Machine
NASA Technical Reports Server (NTRS)
Hodo, James D.; Moore, Dennis R.; Morris, Thomas F.; Tiller, Newton G.
1987-01-01
Fatigue-testing machine applies fluctuating tension to number of specimens at same time. When sample breaks, machine continues to test remaining specimens. Series of tensile tests needed to determine fatigue properties of materials performed more rapidly than in conventional fatigue-testing machine.
Impact of specimen adequacy on the assessment of renal allograft biopsy specimens.
Cimen, S; Geldenhuys, L; Guler, S; Imamoglu, A; Molinari, M
2016-01-01
The Banff classification was introduced to achieve uniformity in the assessment of renal allograft biopsies. The primary aim of this study was to evaluate the impact of specimen adequacy on the Banff classification. All renal allograft biopsies obtained between July 2010 and June 2012 for suspicion of acute rejection were included. Pre-biopsy clinical data on suspected diagnosis and time from renal transplantation were provided to a nephropathologist who was blinded to the original pathological report. Second pathological readings were compared with the original to assess agreement stratified by specimen adequacy. Cohen's kappa test and Fisher's exact test were used for statistical analyses. Forty-nine specimens were reviewed. Among these specimens, 81.6% were classified as adequate, 6.12% as minimal, and 12.24% as unsatisfactory. The agreement analysis among the first and second readings revealed a kappa value of 0.97. Full agreement between readings was found in 75% of the adequate specimens, 66.7 and 50% for minimal and unsatisfactory specimens, respectively. There was no agreement between readings in 5% of the adequate specimens and 16.7% of the unsatisfactory specimens. For the entire sample full agreement was found in 71.4%, partial agreement in 20.4% and no agreement in 8.2% of the specimens. Statistical analysis using Fisher's exact test yielded a P value above 0.25 showing that - probably due to small sample size - the results were not statistically significant. Specimen adequacy may be a determinant of a diagnostic agreement in renal allograft specimen assessment. While additional studies including larger case numbers are required to further delineate the impact of specimen adequacy on the reliability of histopathological assessments, specimen quality must be considered during clinical decision making while dealing with biopsy reports based on minimal or unsatisfactory specimens.
Experimental investigation of time dependent behavior of welded Topopah Spring Tuff
NASA Astrophysics Data System (ADS)
Ma, Lumin
Four types of laboratory tests have been performed. Specimens were attained from four lithophysal zones of the welded Topopah Spring Tuff unit at Yucca Mountain, Nevada: upper lithophysal, middle nonlithophysal, lower lithophysal and lower nonlithophysal zones. Two types of tests are conducted to study time-dependent behavior: constant strain rate and creep tests. Sixty-five specimens from the middle nonlithophysal zone were tested at six strain rates: 10-2, 10-4, 10-5, 10-6, 10-7, and 10-8 s-1. Test durations range from 2 seconds to 7 days. Fourteen specimens from middle nonlithophysal, lower lithophysal and lower nonlithophysal zones are creep tested by incremental stepwise loading. All the tests are conducted under uniaxial compression at room temperature and humidity. Specimens exhibit extremely brittle fracture and fail by axial splitting, and show very little dilatancy if any. It is assumed that microfracturing dominates the inelastic deformation and failure of the tuff. Nonlinear regression is applied to the results of the constant strain rate tests to estimate the relations between peak strength, peak axial strain, secant modulus and strain rate. All three these parameters decrease with a decrease of strain rate and follow power functions: sigmapeak = 271.37 3˙0.0212 0.0212, epsilonpeak = 0.006 3˙0.0083 , ES = 41985.4 3˙0.015 . Secant modulus is introduced mainly as a tool to analyze strain rate dependent axial strain. Two threshold stresses define creep behavior. Below about 50% of peak strength, a specimen does not creep. Above about 94% of peak strength, a specimen creeps at an accelerating rate. Between the two threshold stresses, a power law relates strain rate and stress. One hundred fifty-eight Brazilian (Indirect tensile splitting) tests have been performed at six different constant strain rates. Nineteen lithophysal specimens were tested in uniaxial compression to study their fracture pattern. These specimens have a far less brittle failure mode. They slowly crumble, collapse, and maintain considerable relative strength beyond the peak. Due to the presence of multiple relatively large lithophysal cavities, they are far weaker and softer than the nonlithophysal specimens.
The effect of weld porosity on the cryogenic fatigue strength of ELI grade Ti-5Al-2.5Sn
NASA Technical Reports Server (NTRS)
Rogers, P. R.; Lambdin, R. C.; Fox, D. E.
1992-01-01
The effect of weld porosity on the fatigue strength of ELI grade Ti-5Al-2.5Sn at cryogenic temperature was determined. A series of high cycle fatigue (HCF) and tensile tests were performed at -320 F on specimens made from welded sheets of the material. All specimens were tested with weld beads intact and some amount of weld offset. Specimens containing porosity and control specimens containing no porosity were tested. Results indicate that for the weld configuration tested, the fatigue life of the material is not affected by the presence of spherical embedded pores.
Development of test specimens to obtain the transmission factors to attenuate photons of 0.511 MeV
NASA Astrophysics Data System (ADS)
Costa, J. J. S.; Cardoso, D. D.; Gavazza, S.; Oliveira, C. L.; Morales, R. K.; Amorim, A. S.; Balthar, M. C. V.; Oliveira, L. S. R.
2018-03-01
For designing a shielding, it is necessary, mainly, to determine or have access to the following parameters: transmission factors of the material used and type of radiation to be shielded. Cylindrical test specimens with different thicknesses were developed for experimentally obtaining the material transmission factor for shielding calculation. The cylindrical test specimens were made considering the geometric characteristics of the detector, the ease of production and the energy of 0.511 MeV from the 18F-FDG decay. A type of concrete widely used in Brazil was used in the preparation of the cylindrical test specimens.
Constant-load delayed fracture test of atmospherically corroded high strength steels
NASA Astrophysics Data System (ADS)
Akiyama, Eiji; Matsukado, Katsuhiro; Li, Songjie; Tsuzaki, Kaneaki
2011-07-01
Constant load tests of circumferentially notched round bar specimens of high strength steels after cyclic corrosion test and outdoor exposure have been performed to demonstrate that delayed fracture occurs when the hydrogen content from the environment, H E, exceeds the critical hydrogen content for delayed fracture, H C. During the constant load tests the humidity around the specimen was increased in stepwise manner to increase hydrogen entry. After fracture the specimen was kept at the humidity long enough to homogenize hydrogen in the specimen and to obtain more quantitative hydrogen content by thermal desorption analysis. H E of the fractured specimens was higher than H C, and H E of the specimens not fractured was lower than H C. This result confirms that the balance between H C and H E determines the occurrence of delayed fracture and that hydrogen-content-based evaluation of susceptibility to delayed fracture is reasonable. To certify the increase of H E with increase in humidity, electrochemical hydrogen permeation test was carried out. The hydrogen permeation current density was increased especially at 98%RH. Enhancement of hydrogen entry with increase in CCT number was also shown by the test.
NASA Technical Reports Server (NTRS)
Czabaj, Michael W.; Davidson, Barry D.; Ratcliffe, James G.
2016-01-01
Modifications to the edge crack torsion (ECT) test are studied to improve the reliability of this test for measuring the mode-III fracture toughness, G (sub IIIc), of laminated tape fiber-reinforced polymeric (FRP) composites. First, the data reduction methods currently used in the ECT test are evaluated and deficiencies in their accuracy are discussed. An alternative data reduction technique, which uses a polynomial form to represent ECT specimen compliance solution, is evaluated and compared to FEA (finite element analysis) results. Second, seven batches of ECT specimens are tested, each batch containing specimens with a preimplanted midplane edge delamination and midplane plies with orientations of plus theta divided by minus theta, with theta ranging from 0 degrees to 90 degrees in 15-degree increments. Tests on these specimens show that intralaminar cracking occurs in specimens from all batches except for which theta = 15 degrees and 30 degrees. Tests on specimens of these two batches are shown to result in mode-III delamination growth at the intended ply interface. The findings from this study are encouraging steps towards the use of the ECT test as a standardized method for measuring G (sub IIIc), although further modification to the data reduction method is required to make it suitable for use as part of a standardized test method.
Detection of bacteriuria and pyuria by URISCREEN a rapid enzymatic screening test.
Pezzlo, M T; Amsterdam, D; Anhalt, J P; Lawrence, T; Stratton, N J; Vetter, E A; Peterson, E M; de la Maza, L M
1992-01-01
A multicenter study was performed to evaluate the ability of the URISCREEN (Analytab Products, Plainview, N.Y.), a 2-min catalase tube test, to detect bacteriuria and pyuria. This test was compared with the Chemstrip LN (BioDynamics, Division of Boehringer Mannheim Diagnostics, Indianapolis, Ind.), a 2-min enzyme dipstick test; a semiquantitative plate culture method was used as the reference test for bacteriuria, and the Gram stain or a quantitative chamber count method was used as the reference test for pyuria. Each test was evaluated for its ability to detect probable pathogens at greater than or equal to 10(2) CFU/ml and/or greater than or equal to 1 leukocyte per oil immersion field, as determined by the Gram stain method, or greater than 10 leukocytes per microliter, as determined by the quantitative count method. A total of 1,500 urine specimens were included in this evaluation. There were 298 specimens with greater than or equal 10(2) CFU/ml and 451 specimens with pyuria. Of the 298 specimens with probable pathogens isolated at various colony counts, 219 specimens had colony counts of greater than or equal to 10(5) CFU/ml, 51 specimens had between 10(4) and 10(5) CFU/ml, and 28 specimens had between 10(2) and less than 10(4) CFU/ml. Both the URISCREEN and the Chemstrip LN detected 93% (204 of 219) of the specimens with probable pathogens at greater than or equal to 10(5) CFU/ml. For the specimens with probable pathogens at greater than or equal to 10(2) CFU/ml, the sensitivities of the URISCREEN and the Chemstrip LN were 86% (256 of 298) and 81% (241 of 298), respectively. Of the 451 specimens with pyuria, the URISCREEN detected 88% (398 of 451) and Chemstrip LN detected 78% (350 if 451). There were 204 specimens with both greater than or equal to 10(2) CFU/ml and pyuria; the sensitivities of both methods were 95% (193 of 204) for these specimens. Overall, there were 545 specimens with probable pathogens at greater than or equal to 10(2) CFU/ml and/or pyuria. The URISCREEN detected 85% (461 of 545), and the Chemstrip LN detected 73% (398 of 545). A majority (76%) of the false-negative results obtained with either method were for specimens without leukocytes in the urine. There were 955 specimens with no probable pathogens or leukocytes. Of these, 28% (270 of 955) were found positive by the URISCREEN and 13% (122 of 955) were found positive by the Chemstrip LN. A majority of the false-positive results were probably due, in part, to the detection of enzymes present in both bacterial and somatic cells by each of the test systems. Overall, the URISCREEN is rapid, manual, easy-to-perform enzymatic test that yields findings similar to those yielded by the Chemstrip LN for specimens with both greater than or equal to 10(2) CFU/ml and pyuria or for specimens with greater than or equal to 10(5) CFU/ml and with or without pyuria. However, when the data were analyzed for either probable pathogens at less 10(5) CFU/ml or pyuria, the sensitivity of the URISCREEN was higher (P less than 0.05). PMID:1551986
Hydrostatic Extrusion of 60mm Mortar Tubes
1974-10-01
Transverse "Tensile Test Specimen 16 9. Subsize Charpy and Tensile Test Specimens 17 10. Extruded 718 Alloy Tube Pressure-strain Pressure Test [)ata 18... subsize specimens. (d) Previous studies have shown that the standard size Charpy values are 4.5 times the subsize values. 22 -. •. ., *. ...20 II. Tensile Properties of Extruded and Aged Tube (a) 21 III. Extruded 718 Alloy Pressure Test Data 21 IV. V-Notch Charpy Impact Properties(c) of
Neck forces and moments and head accelerations in side impact.
Yoganandan, Narayan; Pintar, Frank A; Maiman, Dennis J; Philippens, Mat; Wismans, Jac
2009-03-01
Although side-impact sled studies have investigated chest, abdomen, and pelvic injury mechanics, determination of head accelerations and the associated neck forces and moments is very limited. The purpose of the present study was therefore to determine the temporal forces and moments at the upper neck region and head angular accelerations and angular velocities using postmortem human subjects (PMHS). Anthropometric data and X-rays were obtained, and the specimens were positioned upright on a custom-designed seat, rigidly fixed to the platform of the sled. PMHS were seated facing forward with the Frankfort plane horizontal, and legs were stretched parallel to the mid-sagittal plane. The normal curvature and alignment of the dorsal spine were maintained without initial torso rotation. A pyramid-shaped nine-accelerometer package was secured to the parietal-temporal region of the head. The test matrix consisted of groups A and B, representing the fully restrained torso condition, and groups C and D, representing the three-point belt-restrained torso condition. The change in velocity was 12.4 m/s for groups A and C, 17.9 m/s for group B, and 8.7 m/s for group D tests. Two specimens were tested in each group. Injuries were scored based on the Abbreviated Injury Scale. The head mass, center of gravity, and moment of inertia were determined for each specimen. Head accelerations and upper neck forces and moments were determined before head contact. Neck forces and moments and head angular accelerations and angular velocities are presented on a specimen-by-specimen basis. In addition, a summary of peak magnitudes of biomechanical data is provided because of their potential in serving as injury reference values characterizing head-neck biomechanics in side impacts. Though no skull fractures occurred, AIS 0 to 3 neck traumas were dependent on the impact velocity and restraint condition. Because specimen-specific head center of gravity and mass moment of inertia were determined, and a suitable instrumentation system was used for data collection and analysis, head angular accelerations and neck forces and moments determined in the present study can be used with confidence to advance impact biomechanics research. Although the sample size is limited in each group, results from these tests serve as a fundamental data set to validate finite element models and evaluate the performance and biofidelity of federalized and prototype side-impact dummies with a focus on head-neck biomechanics.
Next-Generation Sequencing of Aquatic Oligochaetes: Comparison of Experimental Communities
Vivien, Régis; Lejzerowicz, Franck; Pawlowski, Jan
2016-01-01
Aquatic oligochaetes are a common group of freshwater benthic invertebrates known to be very sensitive to environmental changes and currently used as bioindicators in some countries. However, more extensive application of oligochaetes for assessing the ecological quality of sediments in watercourses and lakes would require overcoming the difficulties related to morphology-based identification of oligochaetes species. This study tested the Next-Generation Sequencing (NGS) of a standard cytochrome c oxydase I (COI) barcode as a tool for the rapid assessment of oligochaete diversity in environmental samples, based on mixed specimen samples. To know the composition of each sample we Sanger sequenced every specimen present in these samples. Our study showed that a large majority of OTUs (Operational Taxonomic Unit) could be detected by NGS analyses. We also observed congruence between the NGS and specimen abundance data for several but not all OTUs. Because the differences in sequence abundance data were consistent across samples, we exploited these variations to empirically design correction factors. We showed that such factors increased the congruence between the values of oligochaetes-based indices inferred from the NGS and the Sanger-sequenced specimen data. The validation of these correction factors by further experimental studies will be needed for the adaptation and use of NGS technology in biomonitoring studies based on oligochaete communities. PMID:26866802
DNA barcoding of human-biting black flies (Diptera: Simuliidae) in Thailand.
Pramual, Pairot; Thaijarern, Jiraporn; Wongpakam, Komgrit
2016-12-01
Black flies (Diptera: Simuliidae) are important insect vectors and pests of humans and animals. Accurate identification, therefore, is important for control and management. In this study, we used mitochondrial cytochrome oxidase I (COI) barcoding sequences to test the efficiency of species identification for the human-biting black flies in Thailand. We used human-biting specimens because they enabled us to link information with previous studies involving the immature stages. Three black fly taxa, Simulium nodosum, S. nigrogilvum and S. doipuiense complex, were collected. The S. doipuiense complex was confirmed for the first time as having human-biting habits. The COI sequences revealed considerable genetic diversity in all three species. Comparisons to a COI sequence library of black flies in Thailand and in a public database indicated a high efficiency for specimen identification for S. nodosum and S. nigrogilvum, but this method was not successful for the S. doipuiense complex. Phylogenetic analyses revealed two divergent lineages in the S. doipuiense complex. Human-biting specimens formed a separate clade from other members of this complex. The results are consistent with the Barcoding Index Number System (BINs) analysis that found six BINs in the S. doipuiense complex. Further taxonomic work is needed to clarify the species status of these human-biting specimens. Copyright © 2016 Elsevier B.V. All rights reserved.