Sample records for test targets comparable

  1. DVA as a Diagnostic Test for Vestibulo-Ocular Reflex Function

    NASA Technical Reports Server (NTRS)

    Wood, Scott J.; Appelbaum, Meghan

    2010-01-01

    The vestibulo-ocular reflex (VOR) stabilizes vision on earth-fixed targets by eliciting eyes movements in response to changes in head position. How well the eyes perform this task can be functionally measured by the dynamic visual acuity (DVA) test. We designed a passive, horizontal DVA test to specifically study the acuity and reaction time when looking in different target locations. Visual acuity was compared among 12 subjects using a standard Landolt C wall chart, a computerized static (no rotation) acuity test and dynamic acuity test while oscillating at 0.8 Hz (+/-60 deg/s). In addition, five trials with yaw oscillation randomly presented a visual target in one of nine different locations with the size and presentation duration of the visual target varying across trials. The results showed a significant difference between the static and dynamic threshold acuities as well as a significant difference between the visual targets presented in the horizontal plane versus those in the vertical plane when comparing accuracy of vision and reaction time of the response. Visual acuity increased proportional to the size of the visual target and increased between 150 and 300 msec duration. We conclude that dynamic visual acuity varies with target location, with acuity optimized for targets in the plane of rotation. This DVA test could be used as a functional diagnostic test for visual-vestibular and neuro-cognitive impairments by assessing both accuracy and reaction time to acquire visual targets.

  2. The Negative Testing Effect and Multifactor Account

    ERIC Educational Resources Information Center

    Peterson, Daniel J.; Mulligan, Neil W.

    2013-01-01

    Across 3 experiments, we investigated the factors that dictate when taking a test improves subsequent memory performance (the "testing effect"). In Experiment 1, participants retrieving a set of targets during a retrieval practice phase ultimately recalled fewer of those targets compared with a group of participants who studied the…

  3. Comparing Science Achievement Constructs: Targeted and Achieved

    ERIC Educational Resources Information Center

    Ferrara, Steve; Duncan, Teresa

    2011-01-01

    This article illustrates how test specifications based solely on academic content standards, without attention to other cognitive skills and item response demands, can fall short of their targeted constructs. First, the authors inductively describe the science achievement construct represented by a statewide sixth-grade science proficiency test.…

  4. Economic Evaluation of Companion Diagnostic Testing for EGFR Mutations and First-Line Targeted Therapy in Advanced Non-Small Cell Lung Cancer Patients in South Korea.

    PubMed

    Lim, Eun-A; Lee, Haeyoung; Bae, Eunmi; Lim, Jaeok; Shin, Young Kee; Choi, Sang-Eun

    2016-01-01

    As targeted therapy becomes increasingly important, diagnostic techniques for identifying targeted biomarkers have also become an emerging issue. The study aims to evaluate the cost-effectiveness of treating patients as guided by epidermal growth factor receptor (EGFR) mutation status compared with a no-testing strategy that is the current clinical practice in South Korea. A cost-utility analysis was conducted to compare an EGFR mutation testing strategy with a no-testing strategy from the Korean healthcare payer's perspective. The study population consisted of patients with stage 3b and 4 lung adenocarcinoma. A decision tree model was employed to select the appropriate treatment regimen according to the results of EGFR mutation testing and a Markov model was constructed to simulate disease progression of advanced non-small cell lung cancer. The length of a Markov cycle was one month, and the time horizon was five years (60 cycles). In the base case analysis, the testing strategy was a dominant option. Quality-adjusted life-years gained (QALYs) were 0.556 and 0.635, and total costs were $23,952 USD and $23,334 USD in the no-testing and testing strategy respectively. The sensitivity analyses showed overall robust results. The incremental cost-effectiveness ratios (ICERs) increased when the number of patients to be treated with erlotinib increased, due to the high cost of erlotinib. Treating advanced adenocarcinoma based on EGFR mutation status has beneficial effects and saves the cost compared to no testing strategy in South Korea. However, the cost-effectiveness of EGFR mutation testing was heavily affected by the cost-effectiveness of the targeted therapy.

  5. Radiology Reports With Hyperlinks Improve Target Lesion Selection and Measurement Concordance in Cancer Trials.

    PubMed

    Machado, Laura B; Apolo, Andrea B; Steinberg, Seth M; Folio, Les R

    2017-02-01

    Radiology reports often lack the measurements of target lesions that are needed for oncology clinical trials. When available, the measurements in the radiology reports often do not match those in the records used to calculate therapeutic response. This study assessed the clinical value of hyperlinked tumor measurements in multimedia-enhanced radiology reports in the PACS and the inclusion of a radiologist assistant in the process of assessing tumor burden. We assessed 489 target lesions in 232 CT examinations of 71 patients with metastatic genitourinary cancer enrolled in two therapeutic trials. We analyzed target lesion selection and measurement concordance between oncology records (used to calculate therapeutic response) and two types of radiology reports in the PACS: multimedia-enhanced radiology reports and text-only reports. For statistical tests, we used the Wilcoxon signed rank, Wilcoxon rank sum test, and Fisher method to combine p values from the paired and unpaired results. The Fisher exact test was used to compare overall measurement concordance. Concordance on target lesion selection was greater for multimedia-enhanced radiology reports (78%) than the text-only reports (52%) (p = 0.0050). There was also improved overall measurement concordance with the multimedia-enhanced radiology reports (68%) compared with the text-only reports (38%) (p < 0.0001). Compared with text-only reports, hyperlinked multimedia-enhanced radiology reports improved concordance of target lesion selection and measurement with the measurements used to calculate therapeutic response.

  6. Target detection, shape discrimination, and signal characteristics of an echolocating false killer whale (Pseudorca crassidens).

    PubMed

    Brill, R L; Pawloski, J L; Helweg, D A; Au, W W; Moore, P W

    1992-09-01

    This study demonstrated the ability of a false killer whale (Pseudorca crassidens) to discriminate between two targets and investigated the parameters of the whale's emitted signals for changes related to test conditions. Target detection performance comparable to the bottlenose dolphin's (Tursiops truncatus) has previously been reported for echolocating false killer whales. No other echolocation capabilities have been reported. A false killer whale, naive to conditioned echolocation tasks, was initially trained to detect a cylinder in a "go/no-go" procedure over ranges of 3 to 8 m. The transition from a detection task to a discrimination task was readily achieved by introducing a spherical comparison target. Finally, the cylinder was successfully compared to spheres of two different sizes and target strengths. Multivariate analyses were used to evaluate the parameters of emitted signals. Duncan's multiple range tests showed significant decreases (df = 185, p less than 0.05) in both source level and bandwidth in the transition from detection to discrimination. Analysis of variance revealed a significant decrease in the number of clicks over test conditions [F(5.26) = 5.23, p less than 0.0001]. These data suggest that the whale relied on cues relevant to target shape as well as target strength, that changes in source level and bandwidth were task-related, that the decrease in clicks was associated with learning experience, and that Pseudorca's ability to discriminate shapes using echolocation may be comparable to that of Tursiops truncatus.

  7. Comparison of conventional ultrasonography and ultrasonography-computed tomography fusion imaging for target identification using digital/real hybrid phantoms: a preliminary study.

    PubMed

    Soyama, Takeshi; Sakuhara, Yusuke; Kudo, Kohsuke; Abo, Daisuke; Wang, Jeff; Ito, Yoichi M; Hasegawa, Yu; Shirato, Hiroki

    2016-07-01

    This preliminary study compared ultrasonography-computed tomography (US-CT) fusion imaging and conventional ultrasonography (US) for accuracy and time required for target identification using a combination of real phantoms and sets of digitally modified computed tomography (CT) images (digital/real hybrid phantoms). In this randomized prospective study, 27 spheres visible on B-mode US were placed at depths of 3.5, 8.5, and 13.5 cm (nine spheres each). All 27 spheres were digitally erased from the CT images, and a radiopaque sphere was digitally placed at each of the 27 locations to create 27 different sets of CT images. Twenty clinicians were instructed to identify the sphere target using US alone and fusion imaging. The accuracy of target identification of the two methods was compared using McNemar's test. The mean time required for target identification and error distances were compared using paired t tests. At all three depths, target identification was more accurate and the mean time required for target identification was significantly less with US-CT fusion imaging than with US alone, and the mean error distances were also shorter with US-CT fusion imaging. US-CT fusion imaging was superior to US alone in terms of accurate and rapid identification of target lesions.

  8. Two Self-Control Procedures in the Reduction of Targeted and Nontargeted Anxieties.

    ERIC Educational Resources Information Center

    Deffenbacher, Jerry L.; And Others

    1979-01-01

    Compared effects of relaxation as self-control and a self-control variant of systematic desensitization in reducing targeted (test anxiety) and nontargeted anxieties with those of wait-list and no-treatment expectancy controls. Groups given relaxation as self-control and modified desensitization reported less debilitating test anxiety than…

  9. Comparison of Deep Brain Stimulation Lead Targeting Accuracy and Procedure Duration between 1.5- and 3-Tesla Interventional Magnetic Resonance Imaging Systems: An Initial 12-Month Experience.

    PubMed

    Southwell, Derek G; Narvid, Jared A; Martin, Alastair J; Qasim, Salman E; Starr, Philip A; Larson, Paul S

    2016-01-01

    Interventional magnetic resonance imaging (iMRI) allows deep brain stimulator lead placement under general anesthesia. While the accuracy of lead targeting has been described for iMRI systems utilizing 1.5-tesla magnets, a similar assessment of 3-tesla iMRI procedures has not been performed. To compare targeting accuracy, the number of lead targeting attempts, and surgical duration between procedures performed on 1.5- and 3-tesla iMRI systems. Radial targeting error, the number of targeting attempts, and procedure duration were compared between surgeries performed on 1.5- and 3-tesla iMRI systems (SmartFrame and ClearPoint systems). During the first year of operation of each system, 26 consecutive leads were implanted using the 1.5-tesla system, and 23 consecutive leads were implanted using the 3-tesla system. There was no significant difference in radial error (Mann-Whitney test, p = 0.26), number of lead placements that required multiple targeting attempts (Fisher's exact test, p = 0.59), or bilateral procedure durations between surgeries performed with the two systems (p = 0.15). Accurate DBS lead targeting can be achieved with iMRI systems utilizing either 1.5- or 3-tesla magnets. The use of a 3-tesla magnet, however, offers improved visualization of the target structures and allows comparable accuracy and efficiency of placement at the selected targets. © 2016 S. Karger AG, Basel.

  10. Evaluating Testing Strategies for Identifying Youths With HIV Infection and Linking Youths to Biomedical and Other Prevention Services

    PubMed Central

    Boyer, Cherrie B.; Chiaramonte, Danielle; Lindeman, Peter; Chutuape, Kate; Cooper-Walker, Bendu; Kapogiannis, Bill G.; Wilson, Craig M.; Fortenberry, J. Dennis

    2017-01-01

    Importance Most human immunodeficiency virus (HIV)–infected youths are unaware of their serostatus (approximately 60%) and therefore not linked to HIV medical or prevention services. The need to identify promising and scalable approaches to promote uptake of HIV testing among youths at risk is critical. Objective To evaluate a multisite HIV testing program designed to encourage localized HIV testing programs focused on self-identified sexual minority males and to link youths to appropriate prevention services after receipt of their test results. Design, Setting, and Participants Testing strategies were evaluated using an observational design during a 9-month period (June 1, 2015, through February 28, 2016). Testing strategies were implemented by 12 adolescent medicine HIV primary care programs and included targeted testing, universal testing, or a combination. Data were collected from local youth at high risk of HIV infection and, specifically, sexual minority males of color. Main Outcomes and Measures Proportion of sexual minority males and sexual minority males of color tested, proportion of previously undiagnosed HIV-positive youths identified, and rates of linkage to prevention services. Results A total of 3301 youths underwent HIV testing. Overall, 35 (3.6%) of those who underwent universal testing in primary care clinical settings, such as emergency departments and community health centers, were sexual minority males (35 [3.6%] were males of color) compared with 236 (46.7%) (201 [39.8%] were males of color) who were tested through targeted testing and 693 (37.8%) (503 [27.4%] were males of color) through combination efforts. Identification of new HIV-positive cases varied by strategy: 1 (0.1%) via universal testing, 39 (2.1%) through combination testing, and 16 (3.2%) through targeted testing. However, when targeted tests were separated from universal testing results for sites using a combined strategy, the rate of newly identified HIV-positive cases identified through universal testing decreased to 1 (0.1%). Rates of new HIV-positive cases identified through targeted testing increased to 49 (6.3%). Youths who tested through targeted testing (416 [85.1%]) were more likely to link successfully to local HIV prevention services, including preexposure prophylaxis, compared with those who underwent universal testing (328 [34.1%]). Conclusions and Relevance The findings suggest that community-based targeted approaches to HIV testing are more effective than universal screening for reaching young sexual minority males (especially males of color), identifying previously undiagnosed HIV-positive youths, and linking HIV-negative youths to relevant prevention services. Targeted, community-based HIV testing strategies hold promise as a scalable and effective means to identify high-risk youths who are unaware of their HIV status. PMID:28418524

  11. A Comparison of Traditional and Self-Control Desensitization.

    ERIC Educational Resources Information Center

    Deffenbacher, Jerry L.; Parks, Donald H.

    1979-01-01

    Compared effectiveness of counterconditioning and self-control models of systematic desensitization in reducing targeted and nontargeted anxieties. Treatments were equally effective in reducing and maintaining reduction of targeted anxiety, debilitating test anxiety. (Author)

  12. Presentation of words to separate hemispheres prevents interword illusory conjunctions.

    PubMed

    Liederman, J; Sohn, Y S

    1999-03-01

    We tested the hypothesis that division of inputs between the hemispheres could prevent interword letter migrations in the form of illusory conjunctions. The task was to decide whether a centrally-presented consonant-vowel-consonant (CVC) target word matched one of four CVC words presented to a single hemisphere or divided between the hemispheres in a subsequent test display. During half of the target-absent trials, known as conjunction trials, letters from two separate words (e.g., "tag" and "cop") in the test display could be mistaken for a target word (e.g., "top"). For the other half of the target-absent trails, the test display did not match any target consonants (Experiment 1, N = 16) or it matched one target consonant (Experiment 2, N = 29), the latter constituting true "feature" trials. Bi- as compared to unihemispheric presentation significantly reduced the number of conjunction, but not feature, errors. Illusory conjunctions did not occur when the words were presented to separate hemispheres.

  13. Drug Target Mining and Analysis of the Chinese Tree Shrew for Pharmacological Testing

    PubMed Central

    Liu, Jie; Lee, Wen-hui; Zhang, Yun

    2014-01-01

    The discovery of new drugs requires the development of improved animal models for drug testing. The Chinese tree shrew is considered to be a realistic candidate model. To assess the potential of the Chinese tree shrew for pharmacological testing, we performed drug target prediction and analysis on genomic and transcriptomic scales. Using our pipeline, 3,482 proteins were predicted to be drug targets. Of these predicted targets, 446 and 1,049 proteins with the highest rank and total scores, respectively, included homologs of targets for cancer chemotherapy, depression, age-related decline and cardiovascular disease. Based on comparative analyses, more than half of drug target proteins identified from the tree shrew genome were shown to be higher similarity to human targets than in the mouse. Target validation also demonstrated that the constitutive expression of the proteinase-activated receptors of tree shrew platelets is similar to that of human platelets but differs from that of mouse platelets. We developed an effective pipeline and search strategy for drug target prediction and the evaluation of model-based target identification for drug testing. This work provides useful information for future studies of the Chinese tree shrew as a source of novel targets for drug discovery research. PMID:25105297

  14. Universal Versus Targeted Screening for Lynch Syndrome: Comparing Ascertainment and Costs Based on Clinical Experience.

    PubMed

    Erten, Mujde Z; Fernandez, Luca P; Ng, Hank K; McKinnon, Wendy C; Heald, Brandie; Koliba, Christopher J; Greenblatt, Marc S

    2016-10-01

    Strategies to screen colorectal cancers (CRCs) for Lynch syndrome are evolving rapidly; the optimal strategy remains uncertain. We compared targeted versus universal screening of CRCs for Lynch syndrome. In 2010-2011, we employed targeted screening (age < 60 and/or Bethesda criteria). From 2012 to 2014, we screened all CRCs. Immunohistochemistry for the four mismatch repair proteins was done in all cases, followed by other diagnostic studies as indicated. We modeled the diagnostic costs of detecting Lynch syndrome and estimated the 5-year costs of preventing CRC by colonoscopy screening, using a system dynamics model. Using targeted screening, 51/175 (29 %) cancers fit criteria and were tested by immunohistochemistry; 15/51 (29 %, or 8.6 % of all CRCs) showed suspicious loss of ≥1 mismatch repair protein. Germline mismatch repair gene mutations were found in 4/4 cases sequenced (11 suspected cases did not have germline testing). Using universal screening, 17/292 (5.8 %) screened cancers had abnormal immunohistochemistry suspicious for Lynch syndrome. Germline mismatch repair mutations were found in only 3/10 cases sequenced (7 suspected cases did not have germline testing). The mean cost to identify Lynch syndrome probands was ~$23,333/case for targeted screening and ~$175,916/case for universal screening at our institution. Estimated costs to identify and screen probands and relatives were: targeted, $9798/case and universal, $38,452/case. In real-world Lynch syndrome management, incomplete clinical follow-up was the major barrier to do genetic testing. Targeted screening costs 2- to 7.5-fold less than universal and rarely misses Lynch syndrome cases. Future changes in testing costs will likely change the optimal algorithm.

  15. Radar target classification method with high accuracy and decision speed performance using MUSIC spectrum vectors and PCA projection

    NASA Astrophysics Data System (ADS)

    Secmen, Mustafa

    2011-10-01

    This paper introduces the performance of an electromagnetic target recognition method in resonance scattering region, which includes pseudo spectrum Multiple Signal Classification (MUSIC) algorithm and principal component analysis (PCA) technique. The aim of this method is to classify an "unknown" target as one of the "known" targets in an aspect-independent manner. The suggested method initially collects the late-time portion of noise-free time-scattered signals obtained from different reference aspect angles of known targets. Afterward, these signals are used to obtain MUSIC spectrums in real frequency domain having super-resolution ability and noise resistant feature. In the final step, PCA technique is applied to these spectrums in order to reduce dimensionality and obtain only one feature vector per known target. In the decision stage, noise-free or noisy scattered signal of an unknown (test) target from an unknown aspect angle is initially obtained. Subsequently, MUSIC algorithm is processed for this test signal and resulting test vector is compared with feature vectors of known targets one by one. Finally, the highest correlation gives the type of test target. The method is applied to wire models of airplane targets, and it is shown that it can tolerate considerable noise levels although it has a few different reference aspect angles. Besides, the runtime of the method for a test target is sufficiently low, which makes the method suitable for real-time applications.

  16. Changes in Manipulative Peak Force Modulation and Time to Peak Thrust among First-Year Chiropractic Students Following a 12-Week Detraining Period.

    PubMed

    Starmer, David J; Guist, Brett P; Tuff, Taylor R; Warren, Sarah C; Williams, Matthew G R

    2016-05-01

    The purpose of this study was to analyze differences in peak force modulation and time-to-peak thrust in posterior-to-anterior (PA) high-velocity-low-amplitude (HVLA) manipulations in first-year chiropractic students prior to and following a 12-week detraining period. Chiropractic students (n=125) performed 2 thrusts prior to and following a 12-week detraining period: total peak force targets were 400 and 600 N, on a force-sensing table using a PA hand contact of the participant's choice (bilateral hypothenar, bilateral thenar, or cross bilateral). Force modulation was compared to defined target total peak force values of 600 and 400 N, and time-to-peak thrust was compared between data sets using 2-tailed paired t-tests. Total peak force for the 600 N intensity varied by 124.11 + 65.77 N during the pre-test and 123.29 + 61.43 N during the post-test compared to the defined target of 600 N (P = .90); total peak force for the 400 N intensity varied by 44.91 + 34.67 N during the pre-test and 44.60 + 32.63 N during the post-test compared to the defined target of 400 N (P = .57). Time-to-peak thrust for the 400 N total peak force was 137.094 + 42.47 milliseconds during the pre-test and 125.385 + 37.46 milliseconds during the post-test (P = .0004); time-to-peak thrust for the 600 N total peak force was 136.835 + 40.48 milliseconds during the pre-test and 125.385 + 33.78 milliseconds during the post-test (P = .03). The results indicate no drop-off in the ability to modulate force for either thrust intensity, but did indicate a statistically significant change in time-to-peak thrust for the 400 N total peak force thrust intensity in first-year chiropractic students following a 12-week detraining period. Copyright © 2016 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  17. Comparison of Brassicaceae species for phytotoxicity testing

    EPA Science Inventory

    We compared four Brassicaceae species for potential use as test species in the EPAs Series 850 vegetative vigor test and other phytotoxicity tests to determine effects of chemicals on non-target plants. Arabidopsis thaliana var. Columbia is commonly used in plant molecular and p...

  18. A single blood test adjusted for different liver fibrosis targets improves fibrosis staging and especially cirrhosis diagnosis.

    PubMed

    Calès, Paul; Boursier, Jérôme; Oberti, Frédéric; Moal, Valérie; Fouchard Hubert, Isabelle; Bertrais, Sandrine; Hunault, Gilles; Rousselet, Marie Christine

    2018-04-01

    Fibrosis blood tests are usually developed using significant fibrosis, which is a unique diagnostic target; however, these tests are employed for other diagnostic targets, such as cirrhosis. We aimed to improve fibrosis staging accuracy by simultaneously targeting biomarkers for several diagnostic targets. A total of 3,809 patients were included, comprising 1,012 individuals with chronic hepatitis C (CHC) into a derivation population and 2,797 individuals into validation populations of different etiologies (CHC, chronic hepatitis B, human immunodeficiency virus/CHC, nonalcoholic fatty liver disease, alcohol) using Metavir fibrosis stages as reference. FibroMeter biomarkers were targeted for different fibrosis-stage combinations into classical scores by logistic regression. Independent scores were combined into a single score reflecting Metavir stages by linear regression and called Multi-FibroMeter Version Second Generation (V2G). The primary objective was to combine the advantages of a test targeted for significant fibrosis (FibroMeter V2G ) with those of a test targeted for cirrhosis (CirrhoMeter V2G ). In the derivation CHC population, we first compared Multi-FibroMeter V2G to FibroMeter V2G and observed significant increases in the cirrhosis area under the receiver operating characteristic curve (AUROC), Obuchowski index (reflecting all fibrosis-stage AUROCs), and classification metric (six classes expressed as a correctly classified percentage) and a nonsignificant increase in significant fibrosis AUROC. Thereafter, we compared it to CirroMeter V2G and observed a nonsignificant increase in the cirrhosis AUROC. In all 3,809 patients, respective accuracies for Multi-FibroMeter V2G and FibroMeter V2G were the following: cirrhosis AUROC, 0.906 versus 0.878 ( P < 0.001; versus CirroMeter V2G , 0.897, P = 0.014); Obuchowski index, 0.795 versus 0.791 ( P = 0.059); classification, 86.0% versus 82.1% ( P < 0.001); significant fibrosis AUROC, 0.833 versus 0.832 ( P = 0.366). Multi-FibroMeter V2G had the highest correlation with the area of portoseptal fibrosis and the highest reproducibility over time. Correct classification rates of Multi-FibroMeter with hyaluronate (V2G, 86.0%) or without (V3G, 86.1%) did not differ ( P = 0.938). Conclusion: Multitargeting biomarkers significantly improves fibrosis staging and especially cirrhosis diagnosis compared to classical single-targeted blood tests. ( Hepatology Communications 2018;2:455-466).

  19. A single blood test adjusted for different liver fibrosis targets improves fibrosis staging and especially cirrhosis diagnosis

    PubMed Central

    Boursier, Jérôme; Oberti, Frédéric; Moal, Valérie; Fouchard Hubert, Isabelle; Bertrais, Sandrine; Hunault, Gilles; Rousselet, Marie Christine

    2018-01-01

    Fibrosis blood tests are usually developed using significant fibrosis, which is a unique diagnostic target; however, these tests are employed for other diagnostic targets, such as cirrhosis. We aimed to improve fibrosis staging accuracy by simultaneously targeting biomarkers for several diagnostic targets. A total of 3,809 patients were included, comprising 1,012 individuals with chronic hepatitis C (CHC) into a derivation population and 2,797 individuals into validation populations of different etiologies (CHC, chronic hepatitis B, human immunodeficiency virus/CHC, nonalcoholic fatty liver disease, alcohol) using Metavir fibrosis stages as reference. FibroMeter biomarkers were targeted for different fibrosis‐stage combinations into classical scores by logistic regression. Independent scores were combined into a single score reflecting Metavir stages by linear regression and called Multi‐FibroMeter Version Second Generation (V2G). The primary objective was to combine the advantages of a test targeted for significant fibrosis (FibroMeterV2G) with those of a test targeted for cirrhosis (CirrhoMeterV2G). In the derivation CHC population, we first compared Multi‐FibroMeterV2G to FibroMeterV2G and observed significant increases in the cirrhosis area under the receiver operating characteristic curve (AUROC), Obuchowski index (reflecting all fibrosis‐stage AUROCs), and classification metric (six classes expressed as a correctly classified percentage) and a nonsignificant increase in significant fibrosis AUROC. Thereafter, we compared it to CirroMeterV2G and observed a nonsignificant increase in the cirrhosis AUROC. In all 3,809 patients, respective accuracies for Multi‐FibroMeterV2G and FibroMeterV2G were the following: cirrhosis AUROC, 0.906 versus 0.878 (P < 0.001; versus CirroMeterV2G, 0.897, P = 0.014); Obuchowski index, 0.795 versus 0.791 (P = 0.059); classification, 86.0% versus 82.1% (P < 0.001); significant fibrosis AUROC, 0.833 versus 0.832 (P = 0.366). Multi‐FibroMeterV2G had the highest correlation with the area of portoseptal fibrosis and the highest reproducibility over time. Correct classification rates of Multi‐FibroMeter with hyaluronate (V2G, 86.0%) or without (V3G, 86.1%) did not differ (P = 0.938). Conclusion: Multitargeting biomarkers significantly improves fibrosis staging and especially cirrhosis diagnosis compared to classical single‐targeted blood tests. (Hepatology Communications 2018;2:455‐466) PMID:29619423

  20. Projection of controlled repeatable real-time moving targets to test and evaluate motion imagery quality

    NASA Astrophysics Data System (ADS)

    Scopatz, Stephen D.; Mendez, Michael; Trent, Randall

    2015-05-01

    The projection of controlled moving targets is key to the quantitative testing of video capture and post processing for Motion Imagery. This presentation will discuss several implementations of target projectors with moving targets or apparent moving targets creating motion to be captured by the camera under test. The targets presented are broadband (UV-VIS-IR) and move in a predictable, repeatable and programmable way; several short videos will be included in the presentation. Among the technical approaches will be targets that move independently in the camera's field of view, as well targets that change size and shape. The development of a rotating IR and VIS 4 bar target projector with programmable rotational velocity and acceleration control for testing hyperspectral cameras is discussed. A related issue for motion imagery is evaluated by simulating a blinding flash which is an impulse of broadband photons in fewer than 2 milliseconds to assess the camera's reaction to a large, fast change in signal. A traditional approach of gimbal mounting the camera in combination with the moving target projector is discussed as an alternative to high priced flight simulators. Based on the use of the moving target projector several standard tests are proposed to provide a corresponding test to MTF (resolution), SNR and minimum detectable signal at velocity. Several unique metrics are suggested for Motion Imagery including Maximum Velocity Resolved (the measure of the greatest velocity that is accurately tracked by the camera system) and Missing Object Tolerance (measurement of tracking ability when target is obscured in the images). These metrics are applicable to UV-VIS-IR wavelengths and can be used to assist in camera and algorithm development as well as comparing various systems by presenting the exact scenes to the cameras in a repeatable way.

  1. Comparative Genomic Analysis of Haemophilus haemolyticus and Nontypeable Haemophilus influenzae and a New Testing Scheme for Their Discrimination.

    PubMed

    Hu, Fang; Rishishwar, Lavanya; Sivadas, Ambily; Mitchell, Gabriel J; Jordan, I King; Murphy, Timothy F; Gilsdorf, Janet R; Mayer, Leonard W; Wang, Xin

    2016-12-01

    Haemophilus haemolyticus has been recently discovered to have the potential to cause invasive disease. It is closely related to nontypeable Haemophilus influenzae (NT H. influenzae). NT H. influenzae and H. haemolyticus are often misidentified because none of the existing tests targeting the known phenotypes of H. haemolyticus are able to specifically identify H. haemolyticus Through comparative genomic analysis of H. haemolyticus and NT H. influenzae, we identified genes unique to H. haemolyticus that can be used as targets for the identification of H. haemolyticus A real-time PCR targeting purT (encoding phosphoribosylglycinamide formyltransferase 2 in the purine synthesis pathway) was developed and evaluated. The lower limit of detection was 40 genomes/PCR; the sensitivity and specificity in detecting H. haemolyticus were 98.9% and 97%, respectively. To improve the discrimination of H. haemolyticus and NT H. influenzae, a testing scheme combining two targets (H. haemolyticus purT and H. influenzae hpd, encoding protein D lipoprotein) was also evaluated and showed 96.7% sensitivity and 98.2% specificity for the identification of H. haemolyticus and 92.8% sensitivity and 100% specificity for the identification of H. influenzae, respectively. The dual-target testing scheme can be used for the diagnosis and surveillance of infection and disease caused by H. haemolyticus and NT H. influenzae. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  2. Comparative Genomic Analysis of Haemophilus haemolyticus and Nontypeable Haemophilus influenzae and a New Testing Scheme for Their Discrimination

    PubMed Central

    Hu, Fang; Rishishwar, Lavanya; Sivadas, Ambily; Mitchell, Gabriel J.; Jordan, I. King; Murphy, Timothy F.; Gilsdorf, Janet R.; Mayer, Leonard W.

    2016-01-01

    Haemophilus haemolyticus has been recently discovered to have the potential to cause invasive disease. It is closely related to nontypeable Haemophilus influenzae (NT H. influenzae). NT H. influenzae and H. haemolyticus are often misidentified because none of the existing tests targeting the known phenotypes of H. haemolyticus are able to specifically identify H. haemolyticus. Through comparative genomic analysis of H. haemolyticus and NT H. influenzae, we identified genes unique to H. haemolyticus that can be used as targets for the identification of H. haemolyticus. A real-time PCR targeting purT (encoding phosphoribosylglycinamide formyltransferase 2 in the purine synthesis pathway) was developed and evaluated. The lower limit of detection was 40 genomes/PCR; the sensitivity and specificity in detecting H. haemolyticus were 98.9% and 97%, respectively. To improve the discrimination of H. haemolyticus and NT H. influenzae, a testing scheme combining two targets (H. haemolyticus purT and H. influenzae hpd, encoding protein D lipoprotein) was also evaluated and showed 96.7% sensitivity and 98.2% specificity for the identification of H. haemolyticus and 92.8% sensitivity and 100% specificity for the identification of H. influenzae, respectively. The dual-target testing scheme can be used for the diagnosis and surveillance of infection and disease caused by H. haemolyticus and NT H. influenzae. PMID:27707939

  3. The testing effect for mediator final test cues and related final test cues in online and laboratory experiments.

    PubMed

    Coppens, Leonora C; Verkoeijen, Peter P J L; Bouwmeester, Samantha; Rikers, Remy M J P

    2016-05-31

    The testing effect is the finding that information that is retrieved during learning is more often correctly retrieved on a final test than information that is restudied. According to the semantic mediator hypothesis the testing effect arises because retrieval practice of cue-target pairs (mother-child) activates semantically related mediators (father) more than restudying. Hence, the mediator-target (father-child) association should be stronger for retrieved than restudied pairs. Indeed, Carpenter (2011) found a larger testing effect when participants received mediators (father) than when they received target-related words (birth) as final test cues. The present study started as an attempt to test an alternative account of Carpenter's results. However, it turned into a series of conceptual (Experiment 1) and direct (Experiment 2 and 3) replications conducted with online samples. The results of these online replications were compared with those of similar existing laboratory experiments through small-scale meta-analyses. The results showed that (1) the magnitude of the raw mediator testing effect advantage is comparable for online and laboratory experiments, (2) in both online and laboratory experiments the magnitude of the raw mediator testing effect advantage is smaller than in Carpenter's original experiment, and (3) the testing effect for related cues varies considerably between online experiments. The variability in the testing effect for related cues in online experiments could point toward moderators of the related cue short-term testing effect. The raw mediator testing effect advantage is smaller than in Carpenter's original experiment.

  4. Visual performance with sport-tinted contact lenses in natural sunlight.

    PubMed

    Erickson, Graham B; Horn, Fraser C; Barney, Tyler; Pexton, Brett; Baird, Richard Y

    2009-05-01

    The use of tinted and clear contact lenses (CLs) in all aspects of life is becoming a more popular occurrence, particularly in athletic activities. This study broadens previous research regarding performance-tinted CLs and their effects on measures of visual performance. Thirty-three subjects (14 male, 19 female) were fitted with clear B&L Optima 38, 50% visible light transmission Amber and 36% visible light transmission Gray-Green Nike Maxsight CLs in an individualized randomized sequence. Subjects were dark-adapted with welding goggles before testing and in between subtests involving a Bailey-Lovie chart and the Haynes Distance Rock test. The sequence of testing was repeated for each lens modality. The Amber and Gray-Green lenses enabled subjects to recover vision faster in bright sunlight compared with clear lenses. Also, subjects were able to achieve better visual recognition in bright sunlight when compared with clear lenses. Additionally, the lenses allowed the subjects to alternate fixation between a bright and shaded target at a more rapid rate in bright sunlight as compared with clear lenses. Subjects preferred both the Amber and Gray-Green lenses over clear lenses in the bright and shadowed target conditions. The results of the current study show that Maxsight Amber and Gray-Green lenses provide better contrast discrimination in bright sunlight, better contrast discrimination when alternating between bright and shaded target conditions, better speed of visual recovery in bright sunlight, and better overall visual performance in bright and shaded target conditions compared with clear lenses.

  5. Wavefront-Guided Versus Wavefront-Optimized Photorefractive Keratectomy: Visual and Military Task Performance.

    PubMed

    Ryan, Denise S; Sia, Rose K; Stutzman, Richard D; Pasternak, Joseph F; Howard, Robin S; Howell, Christopher L; Maurer, Tana; Torres, Mark F; Bower, Kraig S

    2017-01-01

    To compare visual performance, marksmanship performance, and threshold target identification following wavefront-guided (WFG) versus wavefront-optimized (WFO) photorefractive keratectomy (PRK). In this prospective, randomized clinical trial, active duty U.S. military Soldiers, age 21 or over, electing to undergo PRK were randomized to undergo WFG (n = 27) or WFO (n = 27) PRK for myopia or myopic astigmatism. Binocular visual performance was assessed preoperatively and 1, 3, and 6 months postoperatively: Super Vision Test high contrast, Super Vision Test contrast sensitivity (CS), and 25% contrast acuity with night vision goggle filter. CS function was generated testing at five spatial frequencies. Marksmanship performance in low light conditions was evaluated in a firing tunnel. Target detection and identification performance was tested for probability of identification of varying target sets and probability of detection of humans in cluttered environments. Visual performance, CS function, marksmanship, and threshold target identification demonstrated no statistically significant differences over time between the two treatments. Exploratory regression analysis of firing range tasks at 6 months showed no significant differences or correlations between procedures. Regression analysis of vehicle and handheld probability of identification showed a significant association with pretreatment performance. Both WFG and WFO PRK results translate to excellent and comparable visual and military performance. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  6. Inoculating against eyewitness suggestibility via interpolated verbatim vs. gist testing.

    PubMed

    Pansky, Ainat; Tenenboim, Einat

    2011-01-01

    In real-life situations, eyewitnesses often have control over the level of generality in which they choose to report event information. In the present study, we adopted an early-intervention approach to investigate to what extent eyewitness memory may be inoculated against suggestibility, following two different levels of interpolated reporting: verbatim and gist. After viewing a target event, participants responded to interpolated questions that required reporting of target details at either the verbatim or the gist level. After 48 hr, both groups of participants were misled about half of the target details and were finally tested for verbatim memory of all the details. The findings were consistent with our predictions: Whereas verbatim testing was successful in completely inoculating against suggestibility, gist testing did not reduce it whatsoever. These findings are particularly interesting in light of the comparable testing effects found for these two modes of interpolated testing.

  7. Visually directed vs. software-based targeted biopsy compared to transperineal template mapping biopsy in the detection of clinically significant prostate cancer.

    PubMed

    Valerio, Massimo; McCartan, Neil; Freeman, Alex; Punwani, Shonit; Emberton, Mark; Ahmed, Hashim U

    2015-10-01

    Targeted biopsy based on cognitive or software magnetic resonance imaging (MRI) to transrectal ultrasound registration seems to increase the detection rate of clinically significant prostate cancer as compared with standard biopsy. However, these strategies have not been directly compared against an accurate test yet. The aim of this study was to obtain pilot data on the diagnostic ability of visually directed targeted biopsy vs. software-based targeted biopsy, considering transperineal template mapping (TPM) biopsy as the reference test. Prospective paired cohort study included 50 consecutive men undergoing TPM with one or more visible targets detected on preoperative multiparametric MRI. Targets were contoured on the Biojet software. Patients initially underwent software-based targeted biopsies, then visually directed targeted biopsies, and finally systematic TPM. The detection rate of clinically significant disease (Gleason score ≥3+4 and/or maximum cancer core length ≥4mm) of one strategy against another was compared by 3×3 contingency tables. Secondary analyses were performed using a less stringent threshold of significance (Gleason score ≥4+3 and/or maximum cancer core length ≥6mm). Median age was 68 (interquartile range: 63-73); median prostate-specific antigen level was 7.9ng/mL (6.4-10.2). A total of 79 targets were detected with a mean of 1.6 targets per patient. Of these, 27 (34%), 28 (35%), and 24 (31%) were scored 3, 4, and 5, respectively. At a patient level, the detection rate was 32 (64%), 34 (68%), and 38 (76%) for visually directed targeted, software-based biopsy, and TPM, respectively. Combining the 2 targeted strategies would have led to detection rate of 39 (78%). At a patient level and at a target level, software-based targeted biopsy found more clinically significant diseases than did visually directed targeted biopsy, although this was not statistically significant (22% vs. 14%, P = 0.48; 51.9% vs. 44.3%, P = 0.24). Secondary analysis showed similar results. Based on these findings, a paired cohort study enrolling at least 257 men would verify whether this difference is statistically significant. The diagnostic ability of software-based targeted biopsy and visually directed targeted biopsy seems almost comparable, although utility and efficiency both seem to be slightly in favor of the software-based strategy. Ongoing trials are sufficiently powered to prove or disprove these findings. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Whole Genome Sequencing Increases Molecular Diagnostic Yield Compared with Current Diagnostic Testing for Inherited Retinal Disease.

    PubMed

    Ellingford, Jamie M; Barton, Stephanie; Bhaskar, Sanjeev; Williams, Simon G; Sergouniotis, Panagiotis I; O'Sullivan, James; Lamb, Janine A; Perveen, Rahat; Hall, Georgina; Newman, William G; Bishop, Paul N; Roberts, Stephen A; Leach, Rick; Tearle, Rick; Bayliss, Stuart; Ramsden, Simon C; Nemeth, Andrea H; Black, Graeme C M

    2016-05-01

    To compare the efficacy of whole genome sequencing (WGS) with targeted next-generation sequencing (NGS) in the diagnosis of inherited retinal disease (IRD). Case series. A total of 562 patients diagnosed with IRD. We performed a direct comparative analysis of current molecular diagnostics with WGS. We retrospectively reviewed the findings from a diagnostic NGS DNA test for 562 patients with IRD. A subset of 46 of 562 patients (encompassing potential clinical outcomes of diagnostic analysis) also underwent WGS, and we compared mutation detection rates and molecular diagnostic yields. In addition, we compared the sensitivity and specificity of the 2 techniques to identify known single nucleotide variants (SNVs) using 6 control samples with publically available genotype data. Diagnostic yield of genomic testing. Across known disease-causing genes, targeted NGS and WGS achieved similar levels of sensitivity and specificity for SNV detection. However, WGS also identified 14 clinically relevant genetic variants through WGS that had not been identified by NGS diagnostic testing for the 46 individuals with IRD. These variants included large deletions and variants in noncoding regions of the genome. Identification of these variants confirmed a molecular diagnosis of IRD for 11 of the 33 individuals referred for WGS who had not obtained a molecular diagnosis through targeted NGS testing. Weighted estimates, accounting for population structure, suggest that WGS methods could result in an overall 29% (95% confidence interval, 15-45) uplift in diagnostic yield. We show that WGS methods can detect disease-causing genetic variants missed by current NGS diagnostic methodologies for IRD and thereby demonstrate the clinical utility and additional value of WGS. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  9. 42 CFR 493.923 - Syphilis serology.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... a laboratory's response for qualitative and quantitative syphilis tests, the program must compare... under paragraphs (b)(2) and (b)(3) of this section. (2) For quantitative syphilis tests, the program... quantitative syphilis serology tests is the target value ±1 dilution. (3) The criterion for acceptable...

  10. 42 CFR 493.923 - Syphilis serology.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... a laboratory's response for qualitative and quantitative syphilis tests, the program must compare... under paragraphs (b)(2) and (b)(3) of this section. (2) For quantitative syphilis tests, the program... quantitative syphilis serology tests is the target value ±1 dilution. (3) The criterion for acceptable...

  11. 42 CFR 493.923 - Syphilis serology.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... a laboratory's response for qualitative and quantitative syphilis tests, the program must compare... under paragraphs (b)(2) and (b)(3) of this section. (2) For quantitative syphilis tests, the program... quantitative syphilis serology tests is the target value ±1 dilution. (3) The criterion for acceptable...

  12. 42 CFR 493.923 - Syphilis serology.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... a laboratory's response for qualitative and quantitative syphilis tests, the program must compare... under paragraphs (b)(2) and (b)(3) of this section. (2) For quantitative syphilis tests, the program... quantitative syphilis serology tests is the target value ±1 dilution. (3) The criterion for acceptable...

  13. 42 CFR 493.923 - Syphilis serology.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... a laboratory's response for qualitative and quantitative syphilis tests, the program must compare... under paragraphs (b)(2) and (b)(3) of this section. (2) For quantitative syphilis tests, the program... quantitative syphilis serology tests is the target value ±1 dilution. (3) The criterion for acceptable...

  14. 42 CFR 493.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... throughout the reportable range for patient test results. Challenge means, for quantitative tests, an... requirement. Target value for quantitative tests means either the mean of all participant responses after... scientific protocol, a comparative method or a method group (“peer” group) may be used. If the method group...

  15. 42 CFR 493.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... throughout the reportable range for patient test results. Challenge means, for quantitative tests, an... requirement. Target value for quantitative tests means either the mean of all participant responses after... scientific protocol, a comparative method or a method group (“peer” group) may be used. If the method group...

  16. 42 CFR 493.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... throughout the reportable range for patient test results. Challenge means, for quantitative tests, an... requirement. Target value for quantitative tests means either the mean of all participant responses after... scientific protocol, a comparative method or a method group (“peer” group) may be used. If the method group...

  17. 42 CFR 493.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... throughout the reportable range for patient test results. Challenge means, for quantitative tests, an... requirement. Target value for quantitative tests means either the mean of all participant responses after... scientific protocol, a comparative method or a method group (“peer” group) may be used. If the method group...

  18. 42 CFR 493.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... throughout the reportable range for patient test results. Challenge means, for quantitative tests, an... requirement. Target value for quantitative tests means either the mean of all participant responses after... scientific protocol, a comparative method or a method group (“peer” group) may be used. If the method group...

  19. High-Throughput Screening of Therapeutic Neural Stimulation Targets: Toward Principles of Preventing and Treating Post-Traumatic Stress Disorder

    DTIC Science & Technology

    2009-09-01

    onset and averaged across all excited units tested (mean ± SE). 7 SUPPLEMENTAL EXPERIMENTAL PROCEDURES Virus design and production...to baseline level 355 ± 505 ms later. The level of post -light firing did not vary with repeated light exposure (p > 0.7, paired t- test comparing...High-Throughput Screening of Therapeutic Neural Stimulation Targets: Toward Principles of Preventing and Treating Post - Traumatic Stress Disorder

  20. Objective Methods to Test Visual Dysfunction in the Presence of Cognitive Impairment

    DTIC Science & Technology

    2015-12-01

    the eye and 3) purposeful eye movements to track targets that are resolved. Major Findings: Three major objective tests of vision were successfully...developed and optimized to detect disease. These were 1) the pupil light reflex (either comparing the two eyes or independently evaluating each eye ...separately for retina or optic nerve damage, 2) eye movement based analysis of target acquisition, fixation, and eccentric viewing as a means of

  1. Enhanced DNA Sensing via Catalytic Aggregation of Gold Nanoparticles

    PubMed Central

    Huttanus, Herbert M.; Graugnard, Elton; Yurke, Bernard; Knowlton, William B.; Kuang, Wan; Hughes, William L.; Lee, Jeunghoon

    2014-01-01

    A catalytic colorimetric detection scheme that incorporates a DNA-based hybridization chain reaction into gold nanoparticles was designed and tested. While direct aggregation forms an inter-particle linkage from only ones target DNA strand, the catalytic aggregation forms multiple linkages from a single target DNA strand. Gold nanoparticles were functionalized with thiol-modified DNA strands capable of undergoing hybridization chain reactions. The changes in their absorption spectra were measured at different times and target concentrations and compared against direct aggregation. Catalytic aggregation showed a multifold increase in sensitivity at low target concentrations when compared to direct aggregation. Gel electrophoresis was performed to compare DNA hybridization reactions in catalytic and direct aggregation schemes, and the product formation was confirmed in the catalytic aggregation scheme at low levels of target concentrations. The catalytic aggregation scheme also showed high target specificity. This application of a DNA reaction network to gold nanoparticle-based colorimetric detection enables highly-sensitive, field-deployable, colorimetric readout systems capable of detecting a variety of biomolecules. PMID:23891867

  2. Reliabilities of mental rotation tasks: limits to the assessment of individual differences.

    PubMed

    Hirschfeld, Gerrit; Thielsch, Meinald T; Zernikow, Boris

    2013-01-01

    Mental rotation tasks with objects and body parts as targets are widely used in cognitive neuropsychology. Even though these tasks are well established to study between-groups differences, the reliability on an individual level is largely unknown. We present a systematic study on the internal consistency and test-retest reliability of individual differences in mental rotation tasks comparing different target types and orders of presentations. In total n = 99 participants (n = 63 for the retest) completed the mental rotation tasks with hands, feet, faces, and cars as targets. Different target types were presented in either randomly mixed blocks or blocks of homogeneous targets. Across all target types, the consistency (split-half reliability) and stability (test-retest reliabilities) were good or acceptable both for intercepts and slopes. At the level of individual targets, only intercepts showed acceptable reliabilities. Blocked presentations resulted in significantly faster and numerically more consistent and stable responses. Mental rotation tasks-especially in blocked variants-can be used to reliably assess individual differences in global processing speed. However, the assessment of the theoretically important slope parameter for individual targets requires further adaptations to mental rotation tests.

  3. Targeting screening and social marketing to increase detection of acute HIV infection in men who have sex with men in Vancouver, British Columbia.

    PubMed

    Gilbert, Mark; Cook, Darrel; Steinberg, Malcolm; Kwag, Michael; Robert, Wayne; Doupe, Glenn; Krajden, Mel; Rekart, Michael

    2013-10-23

    The contribution of acute HIV infection (AHI) to transmission is widely recognized, and increasing AHI diagnosis capacity can enhance HIV prevention through subsequent behavior change or intervention. We examined the impact of targeted pooled nucleic acid amplification testing (NAAT) and social marketing to increase AHI diagnosis among men who have sex with men (MSM) in Vancouver. Observational study. We implemented pooled NAAT following negative third-generation enzyme immunoassay (EIA) testing for males above 18 years in six clinics accessed by MSM, accompanied by two social marketing campaigns developed by a community gay men's health organization. We compared test volume and diagnosis rates for pre-implementation (April 2006-March 2009) and post-implementation (April 2009-March 2012) periods. After implementation, we used linear regression to examine quarterly trends and calculated diagnostic yield. After implementation, the AHI diagnosis rate significantly increased from 1.03 to 1.84 per 1000 tests, as did quarterly HIV test volumes and acute to non-acute diagnosis ratio. Of the 217 new HIV diagnoses after implementation, 54 (24.9%) were AHIs (25 detected by pooled NAAT only) for an increased diagnostic yield of 11.5%. The average number of prior negative HIV tests (past 2 years) increased significantly for newly diagnosed MSM at the six study clinics compared to other newly diagnosed MSM in British Columbia, per quarter. Targeted implementation of pooled NAAT at clinics accessed by MSM is effective in increasing AHI diagnoses compared to third-generation EIA testing. Social marketing campaigns accompanying pooled NAAT implementation may contribute to increasing AHI diagnoses and frequency of HIV testing.

  4. Comparison of human and algorithmic target detection in passive infrared imagery

    NASA Astrophysics Data System (ADS)

    Weber, Bruce A.; Hutchinson, Meredith

    2003-09-01

    We have designed an experiment that compares the performance of human observers and a scale-insensitive target detection algorithm that uses pixel level information for the detection of ground targets in passive infrared imagery. The test database contains targets near clutter whose detectability ranged from easy to very difficult. Results indicate that human observers detect more "easy-to-detect" targets, and with far fewer false alarms, than the algorithm. For "difficult-to-detect" targets, human and algorithm detection rates are considerably degraded, and algorithm false alarms excessive. Analysis of detections as a function of observer confidence shows that algorithm confidence attribution does not correspond to human attribution, and does not adequately correlate with correct detections. The best target detection score for any human observer was 84%, as compared to 55% for the algorithm for the same false alarm rate. At 81%, the maximum detection score for the algorithm, the same human observer had 6 false alarms per frame as compared to 29 for the algorithm. Detector ROC curves and observer-confidence analysis benchmarks the algorithm and provides insights into algorithm deficiencies and possible paths to improvement.

  5. Recommendations for Methicillin-Resistant Staphylococcus aureus Prevention in Adult ICUs: A Cost-Effectiveness Analysis.

    PubMed

    Whittington, Melanie D; Atherly, Adam J; Curtis, Donna J; Lindrooth, Richard C; Bradley, Cathy J; Campbell, Jonathan D

    2017-08-01

    Patients in the ICU are at the greatest risk of contracting healthcare-associated infections like methicillin-resistant Staphylococcus aureus. This study calculates the cost-effectiveness of methicillin-resistant S aureus prevention strategies and recommends specific strategies based on screening test implementation. A cost-effectiveness analysis using a Markov model from the hospital perspective was conducted to determine if the implementation costs of methicillin-resistant S aureus prevention strategies are justified by associated reductions in methicillin-resistant S aureus infections and improvements in quality-adjusted life years. Univariate and probabilistic sensitivity analyses determined the influence of input variation on the cost-effectiveness. ICU. Hypothetical cohort of adults admitted to the ICU. Three prevention strategies were evaluated, including universal decolonization, targeted decolonization, and screening and isolation. Because prevention strategies have a screening component, the screening test in the model was varied to reflect commonly used screening test categories, including conventional culture, chromogenic agar, and polymerase chain reaction. Universal and targeted decolonization are less costly and more effective than screening and isolation. This is consistent for all screening tests. When compared with targeted decolonization, universal decolonization is cost-saving to cost-effective, with maximum cost savings occurring when a hospital uses more expensive screening tests like polymerase chain reaction. Results were robust to sensitivity analyses. As compared with screening and isolation, the current standard practice in ICUs, targeted decolonization, and universal decolonization are less costly and more effective. This supports updating the standard practice to a decolonization approach.

  6. Impact of Target Distance, Target Size, and Visual Acuity on the Video Head Impulse Test.

    PubMed

    Judge, Paul D; Rodriguez, Amanda I; Barin, Kamran; Janky, Kristen L

    2018-05-01

    The video head impulse test (vHIT) assesses the vestibulo-ocular reflex. Few have evaluated whether environmental factors or visual acuity influence the vHIT. The purpose of this study was to evaluate the influence of target distance, target size, and visual acuity on vHIT outcomes. Thirty-eight normal controls and 8 subjects with vestibular loss (VL) participated. vHIT was completed at 3 distances and with 3 target sizes. Normal controls were subdivided on the basis of visual acuity. Corrective saccade frequency, corrective saccade amplitude, and gain were tabulated. In the normal control group, there were no significant effects of target size or visual acuity for any vHIT outcome parameters; however, gain increased as target distance decreased. The VL group demonstrated higher corrective saccade frequency and amplitude and lower gain as compared with controls. In conclusion, decreasing target distance increases gain for normal controls but not subjects with VL. Preliminarily, visual acuity does not affect vHIT outcomes.

  7. A 4D-optimization concept for scanned ion beam therapy.

    PubMed

    Graeff, Christian; Lüchtenborg, Robert; Eley, John Gordon; Durante, Marco; Bert, Christoph

    2013-12-01

    Scanned carbon beam therapy offers advantageous dose distributions and an increased biological effect. Treating moving targets is complex due to sensitivity to range changes and interplay. We propose a 4D treatment planning concept that considers motion during particle number optimization. The target was subdivided into sectors, one for each motion phase of a 4D-CT. Each sector was non-rigidly transformed to its motion phase and there targeted by a dedicated raster field (RST). Therefore, the resulting 4D-RST compensated target motion and range changes. A 4D treatment control system (TCS) was needed for synchronized delivery to the measured patient motion. 4D-optimized plans were simulated for 9 NSCLC lung cancer patients and compared to static irradiation at end-exhale. A prototype TCS was implemented and successfully tested in a film experiment. The 4D-optimized treatment plan resulted in only slightly lower dose coverage of the target compared to static optimization, with V 95% of 97.9% (median, range 96.5-99.4%) vs. 99.3% (98.5-99.8%), with negligible overdose. The conformity number was comparable at 88.2% (85.1-92.5%) vs. 85.2% (79.9-91.2%) for 4D and static, respectively. We implemented and tested a 4D treatment plan optimization method resulting in highly conformal dose delivery. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  8. Combinatorial support vector machines approach for virtual screening of selective multi-target serotonin reuptake inhibitors from large compound libraries.

    PubMed

    Shi, Z; Ma, X H; Qin, C; Jia, J; Jiang, Y Y; Tan, C Y; Chen, Y Z

    2012-02-01

    Selective multi-target serotonin reuptake inhibitors enhance antidepressant efficacy. Their discovery can be facilitated by multiple methods, including in silico ones. In this study, we developed and tested an in silico method, combinatorial support vector machines (COMBI-SVMs), for virtual screening (VS) multi-target serotonin reuptake inhibitors of seven target pairs (serotonin transporter paired with noradrenaline transporter, H(3) receptor, 5-HT(1A) receptor, 5-HT(1B) receptor, 5-HT(2C) receptor, melanocortin 4 receptor and neurokinin 1 receptor respectively) from large compound libraries. COMBI-SVMs trained with 917-1951 individual target inhibitors correctly identified 22-83.3% (majority >31.1%) of the 6-216 dual inhibitors collected from literature as independent testing sets. COMBI-SVMs showed moderate to good target selectivity in misclassifying as dual inhibitors 2.2-29.8% (majority <15.4%) of the individual target inhibitors of the same target pair and 0.58-7.1% of the other 6 targets outside the target pair. COMBI-SVMs showed low dual inhibitor false hit rates (0.006-0.056%, 0.042-0.21%, 0.2-4%) in screening 17 million PubChem compounds, 168,000 MDDR compounds, and 7-8181 MDDR compounds similar to the dual inhibitors. Compared with similarity searching, k-NN and PNN methods, COMBI-SVM produced comparable dual inhibitor yields, similar target selectivity, and lower false hit rate in screening 168,000 MDDR compounds. The annotated classes of many COMBI-SVMs identified MDDR virtual hits correlate with the reported effects of their predicted targets. COMBI-SVM is potentially useful for searching selective multi-target agents without explicit knowledge of these agents. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. Method calibration of the model 13145 infrared target projectors

    NASA Astrophysics Data System (ADS)

    Huang, Jianxia; Gao, Yuan; Han, Ying

    2014-11-01

    The SBIR Model 13145 Infrared Target Projectors ( The following abbreviation Evaluation Unit ) used for characterizing the performances of infrared imaging system. Test items: SiTF, MTF, NETD, MRTD, MDTD, NPS. Infrared target projectors includes two area blackbodies, a 12 position target wheel, all reflective collimator. It provide high spatial frequency differential targets, Precision differential targets imaged by infrared imaging system. And by photoelectricity convert on simulate signal or digital signal. Applications software (IR Windows TM 2001) evaluate characterizing the performances of infrared imaging system. With regards to as a whole calibration, first differently calibration for distributed component , According to calibration specification for area blackbody to calibration area blackbody, by means of to amend error factor to calibration of all reflective collimator, radiance calibration of an infrared target projectors using the SR5000 spectral radiometer, and to analyze systematic error. With regards to as parameter of infrared imaging system, need to integrate evaluation method. According to regulation with -GJB2340-1995 General specification for military thermal imaging sets -testing parameters of infrared imaging system, the results compare with results from Optical Calibration Testing Laboratory . As a goal to real calibration performances of the Evaluation Unit.

  10. Comparison of three methods to identify the anaerobic threshold during maximal exercise testing in patients with chronic heart failure.

    PubMed

    Beckers, Paul J; Possemiers, Nadine M; Van Craenenbroeck, Emeline M; Van Berendoncks, An M; Wuyts, Kurt; Vrints, Christiaan J; Conraads, Viviane M

    2012-02-01

    Exercise training efficiently improves peak oxygen uptake (V˙O2peak) in patients with chronic heart failure. To optimize training-derived benefit, higher exercise intensities are being explored. The correct identification of anaerobic threshold is important to allow safe and effective exercise prescription. During 48 cardiopulmonary exercise tests obtained in patients with chronic heart failure (59.6 ± 11 yrs; left ventricular ejection fraction, 27.9% ± 9%), ventilatory gas analysis findings and lactate measurements were collected. Three technicians independently determined the respiratory compensation point (RCP), the heart rate turning point (HRTP) and the second lactate turning point (LTP2). Thereafter, exercise intensity (target heart rate and workload) was calculated and compared between the three methods applied. Patients had significantly reduced maximal exercise capacity (68% ± 21% of predicted V˙O2peak) and chronotropic incompetence (74% ± 7% of predicted peak heart rate). Heart rate, workload, and V˙O2 at HRTP and at RCP were not different, but at LTP2, these parameters were significantly (P < 0.0001) higher. Mean target heart rate and target workload calculated using the LTP2 were 5% and 12% higher compared with those calculated using HRTP and RCP, respectively. The calculation of target heart rate based on LTP2 was 5% and 10% higher in 12 of 48 (25%) and 6 of 48 (12.5%) patients, respectively, compared with the other two methods. In patients with chronic heart failure, RCP and HRTP, determined during cardiopulmonary exercise tests, precede the occurrence of LTP2. Target heart rates and workloads used to prescribe tailored exercise training in patients with chronic heart failure based on LTP2 are significantly higher than those derived from HRTP and RCP.

  11. Validating regulatory predictions from diverse bacteria with mutant fitness data

    DOE PAGES

    Sagawa, Shiori; Price, Morgan N.; Deutschbauer, Adam M.; ...

    2017-05-24

    Although transcriptional regulation is fundamental to understanding bacterial physiology, the targets of most bacterial transcription factors are not known. Comparative genomics has been used to identify likely targets of some of these transcription factors, but these predictions typically lack experimental support. Here, we used mutant fitness data, which measures the importance of each gene for a bacterium's growth across many conditions, to test regulatory predictions from RegPrecise, a curated collection of comparative genomics predictions. Because characterized transcription factors often have correlated fitness with one of their targets (either positively or negatively), correlated fitness patterns provide support for the comparative genomicsmore » predictions. At a false discovery rate of 3%, we identified significant cofitness for at least one target of 158 TFs in 107 ortholog groups and from 24 bacteria. Thus, high-throughput genetics can be used to identify a high-confidence subset of the sequence-based regulatory predictions.« less

  12. Validating regulatory predictions from diverse bacteria with mutant fitness data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sagawa, Shiori; Price, Morgan N.; Deutschbauer, Adam M.

    Although transcriptional regulation is fundamental to understanding bacterial physiology, the targets of most bacterial transcription factors are not known. Comparative genomics has been used to identify likely targets of some of these transcription factors, but these predictions typically lack experimental support. Here, we used mutant fitness data, which measures the importance of each gene for a bacterium's growth across many conditions, to test regulatory predictions from RegPrecise, a curated collection of comparative genomics predictions. Because characterized transcription factors often have correlated fitness with one of their targets (either positively or negatively), correlated fitness patterns provide support for the comparative genomicsmore » predictions. At a false discovery rate of 3%, we identified significant cofitness for at least one target of 158 TFs in 107 ortholog groups and from 24 bacteria. Thus, high-throughput genetics can be used to identify a high-confidence subset of the sequence-based regulatory predictions.« less

  13. COMPARISON OF COMPARATIVE GENOMIC HYBRIDIZATIONS TECHNOLOGIES ACROSS MICROARRAY PLATFORMS

    EPA Science Inventory

    Comparative Genomic Hybridization (CGH) measures DNA copy number differences between a reference genome and a test genome. The DNA samples are differentially labeled and hybridized to an immobilized substrate. In early CGH experiments, the DNA targets were hybridized to metaphase...

  14. Request of laboratory liver tests in primary care in Spain: potential savings if appropriateness indicator targets were achieved.

    PubMed

    Salinas, Maria; López-Garrigós, Maite; Flores, Emilio; Uris, Joaquín; Leiva-Salinas, Carlos

    2015-10-01

    Liver laboratory tests are used to screen for liver disease, suggest the underlying cause, estimate the severity, assess prognosis, and monitor the efficacy of therapy. The aim of this study was to compare the liver laboratory tests requesting patterns by GPs in Spain, according to geographic and hospital characteristics, to investigate the degree of requesting appropriateness. One hundred and forty-one clinical laboratories were invited to participate from diverse regions across Spain. They filed out the number of laboratory liver tests requested by GPs for the year 2012. Two types of appropriateness indicators were calculated: every test request per 1000 inhabitants or ratios of related tests requests. The indicator results obtained were compared between the different hospitals, according to their setting, location, and management. The savings generated, if each area would have achieved indicator targets, were calculated. We recruited 76 laboratories covering a population of 17,679,195 inhabitants. GPs requested 20,916,780 laboratory liver tests in the year 2012. No differences were obtained according to their setting. Lactate dehydrogenase and direct bilirubin per 1000 inhabitants were significantly higher in institutions with private management. Largest differences were observed between communities. Nine, 31, 0, and 13 laboratories, respectively, achieved the aspartate aminotransferase, lactate dehydrogenase, γ-glutamyl transpeptidase, and total bilirubin-related alanine aminotransferase indicator targets. Reaching ratios would have resulted in savings of €1,028,468. There was a high variability in the request of liver tests. This emphasizes the need to implement interventions to improve appropriate use of liver tests.

  15. Online education improves pediatric residents' understanding of atopic dermatitis.

    PubMed

    Craddock, Megan F; Blondin, Heather M; Youssef, Molly J; Tollefson, Megha M; Hill, Lauren F; Hanson, Janice L; Bruckner, Anna L

    2018-01-01

    Pediatricians manage skin conditions such as atopic dermatitis (AD) but report that their dermatologic training is inadequate. Online modules may enhance medical education when sufficient didactic or clinical teaching experiences are lacking. We assessed whether an online module about AD improved pediatric residents' knowledge and changed their clinical management of AD. Target and control cohorts of pediatric residents from two institutions were recruited. Target subjects took a 30-question test about AD early in their residency, reviewed the online module, and repeated the test 6 months and 1 year later. The control subjects, who had 1 year of clinical experience but had not reviewed the online module, also took the test. The mean percentage of correct answers was calculated and compared using two-sided, two-sample independent t tests and repeated-measures analysis of variance. For a subset of participants, clinical documentation from AD encounters was reviewed and 13 practice behaviors were compared using the Fisher exact test. Twenty-five subjects in the target cohort and 29 subjects in the control cohort completed the study. The target cohort improved from 18.0 ± 3.2 to 23.4 ± 3.4 correctly answered questions over 1 year (P < .001). This final value was greater than that of the control cohort (20.7 ± 4.5; P = .01). Meaningful differences in practice behaviors were not seen. Pediatric residents who reviewed an online module about AD demonstrated statistically significant improvement in disease-specific knowledge over time and had statistically significantly higher scores than controls. Online dermatology education may effectively supplement traditional clinical teaching. © 2017 Wiley Periodicals, Inc.

  16. Performance Testing of a Photocatalytic Oxidation Module for Spacecraft Cabin Atmosphere Revitalization

    NASA Technical Reports Server (NTRS)

    Perry, Jay L.; Abney, Morgan B.; Frederick, Kenneth R.; Scott, Joseph P.; Kaiser, Mark; Seminara, Gary; Bershitsky, Alex

    2011-01-01

    Photocatalytic oxidation (PCO) is a candidate process technology for use in high volumetric flow rate trace contaminant control applications in sealed environments. The targeted application for PCO as applied to crewed spacecraft life support system architectures is summarized. Technical challenges characteristic of PCO are considered. Performance testing of a breadboard PCO reactor design for mineralizing polar organic compounds in a spacecraft cabin atmosphere is described. Test results are analyzed and compared to results reported in the literature for comparable PCO reactor designs.

  17. Properties of intermodal transfer after dual visuo- and auditory-motor adaptation.

    PubMed

    Schmitz, Gerd; Bock, Otmar L

    2017-10-01

    Previous work documented that sensorimotor adaptation transfers between sensory modalities: When subjects adapt with one arm to a visuomotor distortion while responding to visual targets, they also appear to be adapted when they are subsequently tested with auditory targets. Vice versa, when they adapt to an auditory-motor distortion while pointing to auditory targets, they appear to be adapted when they are subsequently tested with visual targets. Therefore, it was concluded that visuomotor as well as auditory-motor adaptation use the same adaptation mechanism. Furthermore, it has been proposed that sensory information from the trained modality is weighted larger than sensory information from an untrained one, because transfer between sensory modalities is incomplete. The present study tested these hypotheses for dual arm adaptation. One arm adapted to an auditory-motor distortion and the other either to an opposite directed auditory-motor or visuomotor distortion. We found that both arms adapted significantly. However, compared to reference data on single arm adaptation, adaptation in the dominant arm was reduced indicating interference from the non-dominant to the dominant arm. We further found that arm-specific aftereffects of adaptation, which reflect recalibration of sensorimotor transformation rules, were stronger or equally strong when targets were presented in the previously adapted compared to the non-adapted sensory modality, even when one arm adapted visually and the other auditorily. The findings are discussed with respect to a recently published schematic model on sensorimotor adaptation. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Comparative ecotoxicity of chlorantraniliprole to non-target soil invertebrates.

    PubMed

    Lavtižar, Vesna; Berggren, Kristina; Trebše, Polonca; Kraak, Michiel H S; Verweij, Rudo A; van Gestel, Cornelis A M

    2016-09-01

    The insecticide chlorantraniliprole (CAP) is gaining importance in agricultural practice, but data on its possible negative effects on non-target organisms is severely deficient. This study therefore determined CAP toxicity to non-target soil invertebrates playing a crucial role in ecosystem functioning, including springtails (Folsomia candida), isopods (Porcellio scaber), enchytraeids (Enchytraeus crypticus) and oribatid mites (Oppia nitens). In sublethal toxicity tests in Lufa 2.2 soil, chronic exposure to CAP concentrations up to 1000 mg/kgdw did not affect the survival and reproduction of E. crypticus and O. nitens nor the survival, body weight and consumption of P. scaber. In contrast, the survival and reproduction of F. candida was severely affected, with an EC50 for effects on reproduction of 0.14 mg CAP/kgdw. The toxicity of CAP to the reproduction of F. candida was tested in four different soils following OECD guideline 232, and additionally in an avoidance test according to ISO guideline 17512-2. A significantly lower toxicity in soils rich in organic matter was observed, compared to low organic soils. Observations in the avoidance test with F. candida suggest that CAP acted in a prompt way, by affecting collembolan locomotor abilities thus preventing them from escaping contaminated soil. This study shows that CAP may especially pose a risk to non-target soil arthropods closely related to insects, while other soil invertebrates seem rather insensitive. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. A new fetal RHD genotyping test: Costs and benefits of mass testing to target antenatal anti-D prophylaxis in England and Wales

    PubMed Central

    2011-01-01

    Background Postnatal and antenatal anti-D prophylaxis have dramatically reduced maternal sensitisations and cases of rhesus disease in babies born to women with RhD negative blood group. Recent scientific advances mean that non-invasive prenatal diagnosis (NIPD), based on the presence of cell-free fetal DNA in maternal plasma, could be used to target prophylaxis on "at risk" pregnancies where the fetus is RhD positive. This paper provides the first assessment of cost-effectiveness of NIPD-targeted prophylaxis compared to current policies. Methods We conducted an economic analysis of NIPD implementation in England and Wales. Two scenarios were considered. Scenario 1 assumed that NIPD will be only used to target antenatal prophylaxis with serology tests continuing to direct post-delivery prophylaxis. In Scenario 2, NIPD would also displace postnatal serology testing if an RhD negative fetus was identified. Costs were estimated from the provider's perspective for both scenarios together with a threshold royalty fee per test. Incremental costs were compared with clinical implications. Results The basic cost of an NIPD in-house test is £16.25 per sample (excluding royalty fee). The two-dose antenatal prophylaxis policy recommended by NICE is estimated to cost the NHS £3.37 million each year. The estimated threshold royalty fee is £2.18 and £8.83 for Scenarios 1 and 2 respectively. At a £2.00 royalty fee, mass NIPD testing would produce no saving for Scenario 1 and £507,154 per annum for Scenario 2. Incremental cost-effectiveness analysis indicates that, at a test sensitivity of 99.7% and this royalty fee, NIPD testing in Scenario 2 will generate one additional sensitisation for every £9,190 saved. If a single-dose prophylaxis policy were implemented nationally, as recently recommended by NICE, Scenario 2 savings would fall. Conclusions Currently, NIPD testing to target anti-D prophylaxis is unlikely to be sufficiently cost-effective to warrant its large scale introduction in England and Wales. Only minor savings are calculated and, balanced against this, the predicted increase in maternal sensitisations may be unacceptably high. Reliability of NIPD assays still needs to be demonstrated rigorously in different ethnic minority populations. First trimester testing is unlikely to alter this picture significantly although other emerging technologies may. PMID:21244652

  20. A new fetal RHD genotyping test: costs and benefits of mass testing to target antenatal anti-D prophylaxis in England and Wales.

    PubMed

    Szczepura, Ala; Osipenko, Leeza; Freeman, Karoline

    2011-01-18

    Postnatal and antenatal anti-D prophylaxis have dramatically reduced maternal sensitisations and cases of rhesus disease in babies born to women with RhD negative blood group. Recent scientific advances mean that non-invasive prenatal diagnosis (NIPD), based on the presence of cell-free fetal DNA in maternal plasma, could be used to target prophylaxis on "at risk" pregnancies where the fetus is RhD positive. This paper provides the first assessment of cost-effectiveness of NIPD-targeted prophylaxis compared to current policies. We conducted an economic analysis of NIPD implementation in England and Wales. Two scenarios were considered. Scenario 1 assumed that NIPD will be only used to target antenatal prophylaxis with serology tests continuing to direct post-delivery prophylaxis. In Scenario 2, NIPD would also displace postnatal serology testing if an RhD negative fetus was identified. Costs were estimated from the provider's perspective for both scenarios together with a threshold royalty fee per test. Incremental costs were compared with clinical implications. The basic cost of an NIPD in-house test is £16.25 per sample (excluding royalty fee). The two-dose antenatal prophylaxis policy recommended by NICE is estimated to cost the NHS £3.37 million each year. The estimated threshold royalty fee is £2.18 and £8.83 for Scenarios 1 and 2 respectively. At a £2.00 royalty fee, mass NIPD testing would produce no saving for Scenario 1 and £507,154 per annum for Scenario 2. Incremental cost-effectiveness analysis indicates that, at a test sensitivity of 99.7% and this royalty fee, NIPD testing in Scenario 2 will generate one additional sensitisation for every £9,190 saved. If a single-dose prophylaxis policy were implemented nationally, as recently recommended by NICE, Scenario 2 savings would fall. Currently, NIPD testing to target anti-D prophylaxis is unlikely to be sufficiently cost-effective to warrant its large scale introduction in England and Wales. Only minor savings are calculated and, balanced against this, the predicted increase in maternal sensitisations may be unacceptably high. Reliability of NIPD assays still needs to be demonstrated rigorously in different ethnic minority populations. First trimester testing is unlikely to alter this picture significantly although other emerging technologies may.

  1. Improved diagnostic yield compared with targeted gene sequencing panels suggests a role for whole-genome sequencing as a first-tier genetic test

    PubMed Central

    Lionel, Anath C; Costain, Gregory; Monfared, Nasim; Walker, Susan; Reuter, Miriam S; Hosseini, S Mohsen; Thiruvahindrapuram, Bhooma; Merico, Daniele; Jobling, Rebekah; Nalpathamkalam, Thomas; Pellecchia, Giovanna; Sung, Wilson W L; Wang, Zhuozhi; Bikangaga, Peter; Boelman, Cyrus; Carter, Melissa T; Cordeiro, Dawn; Cytrynbaum, Cheryl; Dell, Sharon D; Dhir, Priya; Dowling, James J; Heon, Elise; Hewson, Stacy; Hiraki, Linda; Inbar-Feigenberg, Michal; Klatt, Regan; Kronick, Jonathan; Laxer, Ronald M; Licht, Christoph; MacDonald, Heather; Mercimek-Andrews, Saadet; Mendoza-Londono, Roberto; Piscione, Tino; Schneider, Rayfel; Schulze, Andreas; Silverman, Earl; Siriwardena, Komudi; Snead, O Carter; Sondheimer, Neal; Sutherland, Joanne; Vincent, Ajoy; Wasserman, Jonathan D; Weksberg, Rosanna; Shuman, Cheryl; Carew, Chris; Szego, Michael J; Hayeems, Robin Z; Basran, Raveen; Stavropoulos, Dimitri J; Ray, Peter N; Bowdin, Sarah; Meyn, M Stephen; Cohn, Ronald D; Scherer, Stephen W; Marshall, Christian R

    2018-01-01

    Purpose Genetic testing is an integral diagnostic component of pediatric medicine. Standard of care is often a time-consuming stepwise approach involving chromosomal microarray analysis and targeted gene sequencing panels, which can be costly and inconclusive. Whole-genome sequencing (WGS) provides a comprehensive testing platform that has the potential to streamline genetic assessments, but there are limited comparative data to guide its clinical use. Methods We prospectively recruited 103 patients from pediatric non-genetic subspecialty clinics, each with a clinical phenotype suggestive of an underlying genetic disorder, and compared the diagnostic yield and coverage of WGS with those of conventional genetic testing. Results WGS identified diagnostic variants in 41% of individuals, representing a significant increase over conventional testing results (24% P = 0.01). Genes clinically sequenced in the cohort (n = 1,226) were well covered by WGS, with a median exonic coverage of 40 × ±8 × (mean ±SD). All the molecular diagnoses made by conventional methods were captured by WGS. The 18 new diagnoses made with WGS included structural and non-exonic sequence variants not detectable with whole-exome sequencing, and confirmed recent disease associations with the genes PIGG, RNU4ATAC, TRIO, and UNC13A. Conclusion WGS as a primary clinical test provided a higher diagnostic yield than conventional genetic testing in a clinically heterogeneous cohort. PMID:28771251

  2. Improved diagnostic yield compared with targeted gene sequencing panels suggests a role for whole-genome sequencing as a first-tier genetic test.

    PubMed

    Lionel, Anath C; Costain, Gregory; Monfared, Nasim; Walker, Susan; Reuter, Miriam S; Hosseini, S Mohsen; Thiruvahindrapuram, Bhooma; Merico, Daniele; Jobling, Rebekah; Nalpathamkalam, Thomas; Pellecchia, Giovanna; Sung, Wilson W L; Wang, Zhuozhi; Bikangaga, Peter; Boelman, Cyrus; Carter, Melissa T; Cordeiro, Dawn; Cytrynbaum, Cheryl; Dell, Sharon D; Dhir, Priya; Dowling, James J; Heon, Elise; Hewson, Stacy; Hiraki, Linda; Inbar-Feigenberg, Michal; Klatt, Regan; Kronick, Jonathan; Laxer, Ronald M; Licht, Christoph; MacDonald, Heather; Mercimek-Andrews, Saadet; Mendoza-Londono, Roberto; Piscione, Tino; Schneider, Rayfel; Schulze, Andreas; Silverman, Earl; Siriwardena, Komudi; Snead, O Carter; Sondheimer, Neal; Sutherland, Joanne; Vincent, Ajoy; Wasserman, Jonathan D; Weksberg, Rosanna; Shuman, Cheryl; Carew, Chris; Szego, Michael J; Hayeems, Robin Z; Basran, Raveen; Stavropoulos, Dimitri J; Ray, Peter N; Bowdin, Sarah; Meyn, M Stephen; Cohn, Ronald D; Scherer, Stephen W; Marshall, Christian R

    2018-04-01

    PurposeGenetic testing is an integral diagnostic component of pediatric medicine. Standard of care is often a time-consuming stepwise approach involving chromosomal microarray analysis and targeted gene sequencing panels, which can be costly and inconclusive. Whole-genome sequencing (WGS) provides a comprehensive testing platform that has the potential to streamline genetic assessments, but there are limited comparative data to guide its clinical use.MethodsWe prospectively recruited 103 patients from pediatric non-genetic subspecialty clinics, each with a clinical phenotype suggestive of an underlying genetic disorder, and compared the diagnostic yield and coverage of WGS with those of conventional genetic testing.ResultsWGS identified diagnostic variants in 41% of individuals, representing a significant increase over conventional testing results (24%; P = 0.01). Genes clinically sequenced in the cohort (n = 1,226) were well covered by WGS, with a median exonic coverage of 40 × ±8 × (mean ±SD). All the molecular diagnoses made by conventional methods were captured by WGS. The 18 new diagnoses made with WGS included structural and non-exonic sequence variants not detectable with whole-exome sequencing, and confirmed recent disease associations with the genes PIGG, RNU4ATAC, TRIO, and UNC13A.ConclusionWGS as a primary clinical test provided a higher diagnostic yield than conventional genetic testing in a clinically heterogeneous cohort.

  3. A Comparison of Parallel and Integrated Models for Implementation of Routine HIV Screening in a Large, Urban Emergency Department.

    PubMed

    Hankin, Abigail; Freiman, Heather; Copeland, Brittney; Travis, Natasha; Shah, Bijal

    2016-01-01

    This study compared two approaches for implementation of non-targeted HIV screening in the emergency department (ED): (1) designated HIV counselors screening in parallel with ED care and (2) nurse-based screening integrated into patient triage. A retrospective analysis was performed to compare parallel and integrated screening models using data from the first 12 months of each program. Data for the parallel screening model were extracted from information collected by HIV test counselors and the electronic medical record (EMR). Integrated screening model data were extracted from the EMR and supplemented by data collected by HIV social workers during patient interaction. For both programs, data included demographics, HIV test offer, test acceptance or declination, and test result. A Z-test between two proportions was performed to compare screening frequencies and results. During the first 12 months of parallel screening, approximately 120,000 visits were made to the ED, with 3,816 (3%) HIV tests administered and 65 (2%) new diagnoses of HIV infection. During the first 12 months of integrated screening, 111,738 patients were triaged in the ED, with 16,329 (15%) patients tested and 190 (1%) new diagnoses. Integrated screening resulted in an increased frequency of HIV screening compared with parallel screening (0.15 tests per ED patient visit vs. 0.03 tests per ED patient visit, p<0.001) and an increase in the absolute number of new diagnoses (190 vs. 65), representing a slight decrease in the proportion of new diagnoses (1% vs. 2%, p=0.007). Non-targeted, integrated HIV screening, with test offer and order by ED nurses during patient triage, is feasible and resulted in an increased frequency of HIV screening and a threefold increase in the absolute number of newly identified HIV-positive patients.

  4. A Residual Mass Ballistic Testing Method to Compare Armor Materials or Components (Residual Mass Ballistic Testing Method)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benjamin Langhorst; Thomas M Lillo; Henry S Chu

    2014-05-01

    A statistics based ballistic test method is presented for use when comparing multiple groups of test articles of unknown relative ballistic perforation resistance. The method is intended to be more efficient than many traditional methods for research and development testing. To establish the validity of the method, it is employed in this study to compare test groups of known relative ballistic performance. Multiple groups of test articles were perforated using consistent projectiles and impact conditions. Test groups were made of rolled homogeneous armor (RHA) plates and differed in thickness. After perforation, each residual projectile was captured behind the target andmore » its mass was measured. The residual masses measured for each test group were analyzed to provide ballistic performance rankings with associated confidence levels. When compared to traditional V50 methods, the residual mass (RM) method was found to require fewer test events and be more tolerant of variations in impact conditions.« less

  5. Analysis of Photogrammetry Data from ISIM Mockup

    NASA Technical Reports Server (NTRS)

    Nowak, Maria; Hill, Mike

    2007-01-01

    During ground testing of the Integrated Science Instrument Module (ISIM) for the James Webb Space Telescope (JWST), the ISIM Optics group plans to use a Photogrammetry Measurement System for cryogenic calibration of specific target points on the ISIM composite structure and Science Instrument optical benches and other GSE equipment. This testing will occur in the Space Environmental Systems (SES) chamber at Goddard Space Flight Center. Close range photogrammetry is a 3 dimensional metrology system using triangulation to locate custom targets in 3 coordinates via a collection of digital photographs taken from various locations and orientations. These photos are connected using coded targets, special targets that are recognized by the software and can thus correlate the images to provide a 3 dimensional map of the targets, and scaled via well calibrated scale bars. Photogrammetry solves for the camera location and coordinates of the targets simultaneously through the bundling procedure contained in the V-STARS software, proprietary software owned by Geodetic Systems Inc. The primary objectives of the metrology performed on the ISIM mock-up were (1) to quantify the accuracy of the INCA3 photogrammetry camera on a representative full scale version of the ISIM structure at ambient temperature by comparing the measurements obtained with this camera to measurements using the Leica laser tracker system and (2), empirically determine the smallest increment of target position movement that can be resolved by the PG camera in the test setup, i.e., precision, or resolution. In addition, the geometrical details of the test setup defined during the mockup testing, such as target locations and camera positions, will contribute to the final design of the photogrammetry system to be used on the ISIM Flight Structure.

  6. Microarray Technology for the Diagnosis of Fetal Chromosomal Aberrations: Which Platform Should We Use?

    PubMed Central

    Karampetsou, Evangelia; Morrogh, Deborah; Chitty, Lyn

    2014-01-01

    The advantage of microarray (array) over conventional karyotype for the diagnosis of fetal pathogenic chromosomal anomalies has prompted the use of microarrays in prenatal diagnostics. In this review we compare the performance of different array platforms (BAC, oligonucleotide CGH, SNP) and designs (targeted, whole genome, whole genome, and targeted, custom) and discuss their advantages and disadvantages in relation to prenatal testing. We also discuss the factors to consider when implementing a microarray testing service for the diagnosis of fetal chromosomal aberrations. PMID:26237396

  7. Testing the efficiency of plant artificial microRNAs by transient expression in Nicotiana benthamiana reveals additional action at the translational level

    PubMed Central

    Yu, Shi; Pilot, Guillaume

    2014-01-01

    Artificial microRNAs (amiRNAs) have become an important tool to assess gene functions due to their high efficiency and specificity to decrease target gene expression. Based on the observed degree of complementarity between microRNAs (miRNAs) and their targets, it was widely accepted that plant miRNAs act at the mRNA stability level, while the animal miRNAs act at the translational level. Contrary to these canonical dogmas, recent evidence suggests that both plant and animal miRNAs act at both levels. Nevertheless, it is still impossible to predict the effect of an artificial miRNA on the stability or translation of the target mRNA in plants. Consequently, identifying and discarding inefficient amiRNAs prior to stable plant transformation would help getting suppressed mutants faster and at reduced cost. We designed and tested a method using transient expression of amiRNAs and the corresponding target genes in Nicotiana benthamiana leaves to test the efficacy of amiRNAs for suppression of the target protein accumulation. The ability of the amiRNAs to suppress the target gene expression in N. benthamiana was then compared to that in stably transformed Arabidopsis. It was found that the efficacy of 16 amiRNAs, targeting a total of four genes, varied greatly. The effects of amiRNAs on target mRNA accumulation did not always correlate with target protein accumulation or the corresponding phenotypes, while a similar trend of the silencing efficacy of amiRNAs could be observed between N. benthamiana and stably transformed Arabidopsis. Our results showed that, similar to endogenous plant miRNAs, plant amiRNAs could act at the translational level, a property needed to be taken into account when testing the efficacy of individual amiRNAs. Preliminary tests in N. benthamiana can help determine which amiRNA would be the most likely to suppress target gene expression in stably transformed plants. PMID:25477887

  8. Contextual Cueing Effects Across the Lifespan

    PubMed Central

    MERRILL, EDWARD C.; CONNERS, FRANCES A.; ROSKOS, BEVERLY; KLINGER, MARK R.; KLINGER, LAURA GROFER

    2018-01-01

    The authors evaluated age-related variations in contextual cueing, which reflects the extent to which visuospatial regularities can facilitate search for a target. Previous research produced inconsistent results regarding contextual cueing effects in young children and in older adults, and no study has investigated the phenomenon across the life span. Three groups (6, 20, and 70 years old) were compared. Participants located a designated target stimulus embedded in a context of distractor stimuli. During exposure, the location of the target could be predicted from the location of the distracters in each display. During test, these predictable displays were intermixed with new displays that did not predict the target location. Response times to locating predictable relative to unpredictable targets were compared. All groups exhibited facilitation effects greater than 0 (95% CIs [.02, .11], d = .4; [.01, .12], d = .4; and [.01, .10], d = .4, for the children, young adults, and older adults, respectively) indicating that contextual cueing is robust across a wide age range. The relative magnitude of contextual cueing effects was essentially identical across the age range tested, F(2, 103) = 1.71,ηρ2 = .02. The authors argue that a mechanism that uses environmental covariation is available to all age ranges, but the expression of the contextual cueing may depend on the way it is measured. PMID:23991612

  9. Failure of anthropometry as a facial identification technique using high-quality photographs.

    PubMed

    Kleinberg, Krista F; Vanezis, Peter; Burton, A Mike

    2007-07-01

    Anthropometry can be used in certain circumstances to facilitate comparison of a photograph of a suspect with that of the potential offender from surveillance footage. Experimental research was conducted to determine whether anthropometry has a place in forensic practice in confirming the identity of a suspect from a surveillance video. We examined an existing database of photographic lineups, where one video image was compared against 10 photographs, which has previously been used in psychological research. Target (1) and test (10) photos were of high quality, although taken with a different camera. The anthropometric landmarks of right and left ectocanthions, nasion, and stomion were chosen, and proportions and angle values between these landmarks were measured to compare target with test photos. Results indicate that these measurements failed to accurately identify targets. There was also no indication that any of the landmarks made a better comparison than another. It was concluded that, for these landmarks, this method does not generate the consistent results necessary for use as evidence in a court of law.

  10. Subliminal semantic priming in speech.

    PubMed

    Daltrozzo, Jérôme; Signoret, Carine; Tillmann, Barbara; Perrin, Fabien

    2011-01-01

    Numerous studies have reported subliminal repetition and semantic priming in the visual modality. We transferred this paradigm to the auditory modality. Prime awareness was manipulated by a reduction of sound intensity level. Uncategorized prime words (according to a post-test) were followed by semantically related, unrelated, or repeated target words (presented without intensity reduction) and participants performed a lexical decision task (LDT). Participants with slower reaction times in the LDT showed semantic priming (faster reaction times for semantically related compared to unrelated targets) and negative repetition priming (slower reaction times for repeated compared to semantically related targets). This is the first report of semantic priming in the auditory modality without conscious categorization of the prime.

  11. Subliminal Semantic Priming in Speech

    PubMed Central

    Tillmann, Barbara; Perrin, Fabien

    2011-01-01

    Numerous studies have reported subliminal repetition and semantic priming in the visual modality. We transferred this paradigm to the auditory modality. Prime awareness was manipulated by a reduction of sound intensity level. Uncategorized prime words (according to a post-test) were followed by semantically related, unrelated, or repeated target words (presented without intensity reduction) and participants performed a lexical decision task (LDT). Participants with slower reaction times in the LDT showed semantic priming (faster reaction times for semantically related compared to unrelated targets) and negative repetition priming (slower reaction times for repeated compared to semantically related targets). This is the first report of semantic priming in the auditory modality without conscious categorization of the prime. PMID:21655277

  12. Molecular Analysis of Sarcoidosis Granulomas Reveals Antimicrobial Targets

    PubMed Central

    Celada, Lindsay J.; Polosukhin, Vasiliy V.; Atkinson, James B.; Drake, Wonder P.

    2016-01-01

    Sarcoidosis is a granulomatous disease of unknown cause. Prior molecular and immunologic studies have confirmed the presence of mycobacterial virulence factors, such as catalase peroxidase and superoxide dismutase A, within sarcoidosis granulomas. Molecular analysis of granulomas can identify targets of known antibiotics classes. Currently, major antibiotics are directed against DNA synthesis, protein synthesis, and cell wall formation. We conducted molecular analysis of 40 sarcoidosis diagnostic specimens and compared them with 33 disease control specimens for the presence of mycobacterial genes that encode antibiotic targets. We assessed for genes involved in DNA synthesis (DNA gyrase A [gyrA] and DNA gyrase B), protein synthesis (RNA polymerase subunit β), cell wall synthesis (embCAB operon and enoyl reductase), and catalase peroxidase. Immunohistochemical analysis was conducted to investigate the locale of mycobacterial genes such as gyrA within 12 sarcoidosis specimens and 12 disease controls. Mycobacterial DNA was detected in 33 of 39 sarcoidosis specimens by quantitative real-time polymerase chain reaction compared with 2 of 30 disease control specimens (P < 0.001, two-tailed Fisher’s test). Twenty of 39 were positive for three or more mycobacterial genes, compared with 1 of 30 control specimens (P < 0.001, two-tailed Fisher’s test). Immunohistochemistry analysis localized mycobacterial gyrA nucleic acids to sites of granuloma formation in 9 of 12 sarcoidosis specimens compared with 1 of 12 disease controls (P < 0.01). Microbial genes encoding enzymes that can be targeted by currently available antimycobacterial antibiotics are present in sarcoidosis specimens and localize to sites of granulomatous inflammation. Use of antimicrobials directed against target enzymes may be an innovative treatment alternative. PMID:26807608

  13. Panel-based Genetic Diagnostic Testing for Inherited Eye Diseases is Highly Accurate and Reproducible and More Sensitive for Variant Detection Than Exome Sequencing

    PubMed Central

    Bujakowska, Kinga M.; Sousa, Maria E.; Fonseca-Kelly, Zoë D.; Taub, Daniel G.; Janessian, Maria; Wang, Dan Yi; Au, Elizabeth D.; Sims, Katherine B.; Sweetser, David A.; Fulton, Anne B.; Liu, Qin; Wiggs, Janey L.; Gai, Xiaowu; Pierce, Eric A.

    2015-01-01

    Purpose Next-generation sequencing (NGS) based methods are being adopted broadly for genetic diagnostic testing, but the performance characteristics of these techniques have not been fully defined with regard to test accuracy and reproducibility. Methods We developed a targeted enrichment and NGS approach for genetic diagnostic testing of patients with inherited eye disorders, including inherited retinal degenerations, optic atrophy and glaucoma. In preparation for providing this Genetic Eye Disease (GEDi) test on a CLIA-certified basis, we performed experiments to measure the sensitivity, specificity, reproducibility as well as the clinical sensitivity of the test. Results The GEDi test is highly reproducible and accurate, with sensitivity and specificity for single nucleotide variant detection of 97.9% and 100%, respectively. The sensitivity for variant detection was notably better than the 88.3% achieved by whole exome sequencing (WES) using the same metrics, due to better coverage of targeted genes in the GEDi test compared to commercially available exome capture sets. Prospective testing of 192 patients with IRDs indicated that the clinical sensitivity of the GEDi test is high, with a diagnostic rate of 51%. Conclusion The data suggest that based on quantified performance metrics, selective targeted enrichment is preferable to WES for genetic diagnostic testing. PMID:25412400

  14. Variations in accommodation and convergence responses in a minimally controlled photorefractive setting.

    PubMed

    Horwood, A M; Turner, J E; Houston, S M; Riddell, P M

    2001-11-01

    A remote haploscopic photorefractor, designed for assessment of accommodation and convergence in infants and clinical groups, was used to determine heterophoria accommodative convergence/accommodation (AC/A) ratios in normal naïve adults. These were compared with conventional clinical measures. Twenty-one naïve subjects were used to compare occluded and unoccluded prism cover test responses with the remote haploscopic photorefractor using a text and picture target. Although luminance was generally low for both targets, binocular vergences were appropriate for target demand in both studies. Binocular accommodation showed greater lag for the highest target accommodative demand and the less demanding target. Occlusion not only reduced vergence response, but also frequently caused a marked reduction in accommodation, especially to the picture target. Normal mean AC/A values were found, but with wide variations between individual subjects. Although mean accommodation, vergence, and AC/A values were comparable with published data, we suggest that in these conditions using naïve subjects, accommodation is frequently inaccurate, especially on occlusion, without concomitant loss of vergence, at least at low light levels. Accommodative convergence may play a less important part in, and other cues contribute more to, the near reflex than has been previously suggested.

  15. Improving the inhibitory control task to detect minimal hepatic encephalopathy.

    PubMed

    Amodio, Piero; Ridola, Lorenzo; Schiff, Sami; Montagnese, Sara; Pasquale, Chiara; Nardelli, Silvia; Pentassuglio, Ilaria; Trezza, Maria; Marzano, Chiara; Flaiban, Cristiana; Angeli, Paolo; Cona, Giorgia; Bisiacchi, Patrizia; Gatta, Angelo; Riggio, Oliviero

    2010-08-01

    Quantification of the number of noninhibited responses (lures) in the inhibitory control task (ICT) has been proposed for the diagnosis of minimal hepatic encephalopathy (MHE). We assessed the efficacy of ICT compared with recommended diagnostic standards. We studied patients with cirrhosis and healthy individuals (controls) who underwent the ICT at 2 centers (center A: n=51 patients and 41 controls, center B: n=24 patients and 14 controls). Subjects were evaluated for MHE by psychometric hepatic encephalopathy score (PHES). Patients from center B also were assessed for MHE by critical flicker frequency and spectral electroencephalogram analyses. Patients with cirrhosis had higher ICT lures (23.2+/-12.8 vs 12.9+/-5.8, respectively, P<.01) and lower ICT target accuracy (0.88+/-0.17 vs 0.96+/-0.03, respectively, P<.01) compared with controls. However, lures were comparable (25.2+/-12.5 vs 21.4+/-13.9, respectively, P=.32) among patients with/without altered PHES (center A). There was a reverse, U-shaped relationship between ICT lure and target accuracy; a variable adjusting lures was devised based on target accuracy (weighted lures at center B). This variable differed between patients with and without MHE. The variable weighted lures was then validated from data collected at center A by receiver operator characteristic curve analysis; it discriminated between patients with and without PHES alterations (area under the curve=0.71+/-0.07). However, target accuracy alone was as effective as a stand-alone variable (area under the curve=0.81+/-0.06). The ICT is not useful for the diagnosis of MHE, unless adjusted by target accuracy. Testing inhibition (lures) does not seem to be superior to testing attention (target accuracy) for the detection of MHE. Copyright (c) 2010 AGA Institute. Published by Elsevier Inc. All rights reserved.

  16. The Dynamics of Scaling: A Memory-Based Anchor Model of Category Rating and Absolute Identification

    ERIC Educational Resources Information Center

    Petrov, Alexander A.; Anderson, John R.

    2005-01-01

    A memory-based scaling model--ANCHOR--is proposed and tested. The perceived magnitude of the target stimulus is compared with a set of anchors in memory. Anchor selection is probabilistic and sensitive to similarity, base-level strength, and recency. The winning anchor provides a reference point near the target and thereby converts the global…

  17. Effects of Target Probability and Memory Demands on the Vigilance of Adults with and without Mental Retardation.

    ERIC Educational Resources Information Center

    Tomporowski, Phillip D.; Tinsley, Veronica

    1994-01-01

    The vigilance of young adults with and without mild mental retardation (MR) was compared, with subjects performing two memory demanding, cognitively based tests. The vigilance decrement of MR adults declined more rapidly than did the vigilance of non-MR adults, due to an interaction between target detectability and response bias, and poor target…

  18. A Comparative Study on the Teaching Effects of TRIZ Courses for the Humanities

    ERIC Educational Resources Information Center

    Luo, Lingling; Li, Peng; Zhang, Ping

    2017-01-01

    In order to test the feasibility of the curriculum system of TRIZ used in humanities and social science majors, this study will test whether it is effective to cultivate students' creativity and to train their ability to solve problems. This study designs the randomly experimental targets in the two control groups for pretest and post-test. This…

  19. Mock Target Window OTR and IR Design and Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wass, Alexander Joseph

    In order to fully verify temperature measurements made on the target window using infrared (IR) optical non-contact methods, actual comparative measurements are made with a real beam distribution as the heat source using Argonne National Laboratory’s (ANL) 35 MeV electron accelerator. Using Monte Carlo N-Particle (MCNP) simulations and thermal Finite Element Analysis (FEA), a cooled mock target window with thermocouple implants is designed to be used in such a test to achieve window temperatures up to 700°C. An uncoated and blackcoated mock window is designed to enhance the IR temperature measurements and verify optical transmitted radiation (OTR) imagery. This allowsmore » us to fully verify and characterize our temperature accuracy with our current IR camera method and any future method we may wish to explore using actual production conditions. This test also provides us with valuable conclusions/concerns regarding the calibration method we developed using our IR test stand at TA-53 in MPF-14.« less

  20. Discriminating between camouflaged targets by their time of detection by a human-based observer assessment method

    NASA Astrophysics Data System (ADS)

    Selj, G. K.; Søderblom, M.

    2015-10-01

    Detection of a camouflaged object in natural sceneries requires the target to be distinguishable from its local background. The development of any new camouflage pattern therefore has to rely on a well-founded test methodology - which has to be correlated with the final purpose of the pattern - as well as an evaluation procedure, containing the optimal criteria for i) discriminating between the targets and then eventually ii) for a final rank of the targets. In this study we present results from a recent camouflage assessment trial where human observers were used in a search by photo methodology to assess generic test camouflage patterns. We conducted a study to investigate possible improvements in camouflage patterns for battle dress uniforms. The aim was to do a comparative study of potential, and generic patterns intended for use in arid areas (sparsely vegetated, semi desert). We developed a test methodology that was intended to be simple, reliable and realistic with respect to the operational benefit of camouflage. Therefore we chose to conduct a human based observer trial founded on imagery of realistic targets in natural backgrounds. Inspired by a recent and similar trial in the UK, we developed new and purpose-based software to be able to conduct the observer trial. Our preferred assessment methodology - the observer trial - was based on target recordings in 12 different, but operational relevant scenes, collected in a dry and sparsely vegetated area (Rhodes). The scenes were chosen with the intention to span as broadly as possible. The targets were human-shaped mannequins and were situated identically in each of the scenes to allow for a relative comparison of camouflage effectiveness in each scene. Test of significance, among the targets' performance, was carried out by non-parametric tests as the corresponding time of detection distributions in overall were found to be difficult to parameterize. From the trial, containing 12 different scenes from sparsely vegetated areas we collected detection time's distributions for 6 generic targets through visual search by 148 observers. We found that the different targets performed differently, given by their corresponding time of detection distributions, within a single scene. Furthermore, we gained an overall ranking over all the 12 scenes by performing a weighted sum over all scenes, intended to keep as much of the vital information on the targets' signature effectiveness as possible. Our results show that it was possible to measure the targets performance relatively to another also when summing over all scenes. We also compared our ranking based on our preferred criterion (detection time) with a secondary (probability of detection) to assess the sensitivity of a final ranking based upon the test set-up and evaluation criterion. We found our observer-based approach to be well suited regarding its ability to discriminate between similar targets and to assign numeric values to the observed differences in performance. We believe our approach will be well suited as a tool whenever different aspects of camouflage are to be evaluated and understood further.

  1. Sigma metrics used to assess analytical quality of clinical chemistry assays: importance of the allowable total error (TEa) target.

    PubMed

    Hens, Koen; Berth, Mario; Armbruster, Dave; Westgard, Sten

    2014-07-01

    Six Sigma metrics were used to assess the analytical quality of automated clinical chemistry and immunoassay tests in a large Belgian clinical laboratory and to explore the importance of the source used for estimation of the allowable total error. Clinical laboratories are continually challenged to maintain analytical quality. However, it is difficult to measure assay quality objectively and quantitatively. The Sigma metric is a single number that estimates quality based on the traditional parameters used in the clinical laboratory: allowable total error (TEa), precision and bias. In this study, Sigma metrics were calculated for 41 clinical chemistry assays for serum and urine on five ARCHITECT c16000 chemistry analyzers. Controls at two analyte concentrations were tested and Sigma metrics were calculated using three different TEa targets (Ricos biological variability, CLIA, and RiliBÄK). Sigma metrics varied with analyte concentration, the TEa target, and between/among analyzers. Sigma values identified those assays that are analytically robust and require minimal quality control rules and those that exhibit more variability and require more complex rules. The analyzer to analyzer variability was assessed on the basis of Sigma metrics. Six Sigma is a more efficient way to control quality, but the lack of TEa targets for many analytes and the sometimes inconsistent TEa targets from different sources are important variables for the interpretation and the application of Sigma metrics in a routine clinical laboratory. Sigma metrics are a valuable means of comparing the analytical quality of two or more analyzers to ensure the comparability of patient test results.

  2. HIV testing in Europe: Evaluating the impact, added value, relevance and usability of the European Centre for Disease Prevention and Control (ECDC)'s 2010 HIV testing guidance.

    PubMed

    Sullivan, Ann K; Sperle, Ida; Raben, Dorthe; Amato-Gauci, Andrew J; Lundgren, Jens Dilling; Yazdanpanah, Yazdan; Jakobsen, Stine Finne; Tavoschi, Lara

    2017-11-01

    An evaluation of the 2010 ECDC guidance on HIV testing, conducted in October 2015-January 2016, assessed its impact, added value, relevance and usability and the need for updated guidance. Data sources were two surveys: one for the primary target audience (health policymakers and decision makers, national programme managers and ECDC official contact points in the European Union/European Economic Area (EU/EEA) countries and one for a broader target audience (clinicians, civil society organisations and international public health agencies); two moderated focus group discussions  (17 participants each); webpage access data; a literature citation review; and an expert consultation (18 participants) to discuss the evaluation findings. Twenty-three of 28 primary target audience and 31 of 51 broader target audience respondents indicated the guidance was the most relevant when compared with other international guidance. Primary target audience respondents in 11 of 23 countries reported that they had used the guidance in development, monitoring and/or evaluation of their national HIV testing policy, guidelines, programme and/or strategy, and 29 of 51 of the broader target audience respondents reported having used the guidance in their work. Both the primary and broader target audience considered it important or very important to have an EU/EEA-level HIV testing guidance (23/28 and 46/51, respectively). The guidance has been widely used to develop policies, guidelines, programmes and strategies in the EU/EEA and should be regularly updated due to continuous developments in the field in order to continue to serve as an important reference guidance in the region.

  3. HIV testing in Europe: Evaluating the impact, added value, relevance and usability of the European Centre for Disease Prevention and Control (ECDC)’s 2010 HIV testing guidance

    PubMed Central

    Sullivan, Ann K; Sperle, Ida; Raben, Dorthe; Amato-Gauci, Andrew J; Lundgren, Jens Dilling; Yazdanpanah, Yazdan; Jakobsen, Stine Finne; Tavoschi, Lara

    2017-01-01

    Background: An evaluation of the 2010 ECDC guidance on HIV testing, conducted in October 2015–January 2016, assessed its impact, added value, relevance and usability and the need for updated guidance. Methods: Data sources were two surveys: one for the primary target audience (health policymakers and decision makers, national programme managers and ECDC official contact points in the European Union/European Economic Area (EU/EEA) countries and one for a broader target audience (clinicians, civil society organisations and international public health agencies); two moderated focus group discussions  (17 participants each); webpage access data; a literature citation review; and an expert consultation (18 participants) to discuss the evaluation findings. Results: Twenty-three of 28 primary target audience and 31 of 51 broader target audience respondents indicated the guidance was the most relevant when compared with other international guidance. Primary target audience respondents in 11 of 23 countries reported that they had used the guidance in development, monitoring and/or evaluation of their national HIV testing policy, guidelines, programme and/or strategy, and 29 of 51 of the broader target audience respondents reported having used the guidance in their work. Both the primary and broader target audience considered it important or very important to have an EU/EEA-level HIV testing guidance (23/28 and 46/51, respectively). Conclusion: The guidance has been widely used to develop policies, guidelines, programmes and strategies in the EU/EEA and should be regularly updated due to continuous developments in the field in order to continue to serve as an important reference guidance in the region. PMID:29208158

  4. Dynamic visual acuity using "far" and "near" targets

    NASA Technical Reports Server (NTRS)

    Peters, Brian T.; Bloomberg, Jacob J.

    2005-01-01

    CONCLUSIONS: DVA may be useful for assessing the functional consequences of an impaired gaze stabilization mechanism or for testing the effectiveness of a rehabilitation paradigm. Because target distance influences the relative contributions of canal and otolith inputs, the ability to measure DVA at near and far viewing distances may also lead to tests that will independently assess canal and otolith function. OBJECTIVE: To present and test a methodology that uses dynamic visual acuity (DVA) to assess the efficacy of compensatory gaze mechanisms during a functionally relevant activity that differentially measures canal and otolith function. MATERIAL AND METHODS: The effect of treadmill walking at a velocity of 1.79 m/s on subjects' visual acuity was assessed at each of two viewing distances. A custom-written threshold determination program was used to display Landolt C optotypes on a laptop computer screen during a "far" (4 m) target condition and on a micro-display for a "near" (50 cm) target condition. The walking acuity scores for each target distance were normalized by subtracting a corresponding acuity measure obtained while standing still on the treadmill belt. RESULTS: As predicted by subjective reports of relative target motion, the decrease in visual acuity was significantly greater (p < 0.00001) for the near compared to the far condition.

  5. The impact of rotator cuff tendinopathy on proprioception, measuring force sensation.

    PubMed

    Maenhout, Annelies G; Palmans, Tanneke; De Muynck, Martine; De Wilde, Lieven F; Cools, Ann M

    2012-08-01

    The impact of rotator cuff tendinopathy and related impingement on proprioception is not well understood. Numerous quantitative and qualitative changes in shoulder muscles have been shown in patients with rotator cuff tendinopathy. These findings suggest that control of force might be affected. This investigation wants to evaluate force sensation, a submodality of proprioception, in patients with rotator cuff tendinopathy. Thirty-six patients with rotator cuff tendinopathy and 30 matched healthy subjects performed force reproduction tests to isometric external and internal rotation to investigate how accurately they could reproduce a fixed target (50% MVC). Relative error, constant error, and force steadiness were calculated to evaluate respectively magnitude of error made during the test, direction of this error (overshoot or undershoot), and fluctuations of produced forces. Patients significantly overshoot the target (mean, 6.04% of target) while healthy subjects underestimate the target (mean, -5.76% of target). Relative error and force steadiness are similar in patients with rotator cuff tendinopathy and healthy subjects. Force reproduction tests, as executed in this study, were found to be highly reliable (ICC 0.849 and 0.909). Errors were significantly larger during external rotation tests, compared to internal rotation. Patients overestimate the target during force reproduction tests. This should be taken into account in the rehabilitation of patients with rotator cuff tendinopathy; however, precision of force sensation and steadiness of force exertion remains unaltered. This might indicate that control of muscle force is preserved. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  6. Uninvolved versus target muscle contraction during contract: relax proprioceptive neuromuscular facilitation stretching.

    PubMed

    Azevedo, Daniel Camara; Melo, Raphael Marques; Alves Corrêa, Ricardo Vidal; Chalmers, Gordon

    2011-08-01

    The purpose of this study was to compare the acute effect of the contract-relax (CR) stretching technique on knee active range of motion (ROM) using target muscle contraction or an uninvolved muscle contraction. pre-test post-test control experimental design. Clinical research laboratory. Sixty healthy men were randomly assigned to one of three groups. The Contract-Relax group (CR) performed a traditional hamstring CR stretch, the Modified Contract-Relax group (MCR) performed hamstring CR stretching using contraction of an uninvolved muscle distant from the target muscle, and the Control group (CG) did not stretch. Active knee extension test was performed before and after the stretching procedure. Two-way between-within analysis of variance (ANOVA) results showed a significant interaction between group and pre-test to post-test (p < 0.001). Post-hoc examination of individual groups showed no significant change in ROM for the CG (0.8°, p = 0.084), and a significant moderate increase in ROM for both the CR (7.0°, p < 0.001) and MCR (7.0°, p < 0.001) groups. ROM gain following a CR PNF procedure is the same whether the target stretching muscle is contracted, or an uninvolved muscle is contracted. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Field tests of a handheld laser communications/position-finding binocular system

    NASA Astrophysics Data System (ADS)

    Chan, Victor J.; Rivers, Michael D.; Harris, Amy L.

    1998-01-01

    Lasers provide a means for transmitting larger quantities of data at higher rates than conventional radio frequency devices and can be utilized during radio silent operations on the battle field. A forward scout needs to be able to observe the positions of various targets and relay that information back to a tactical operations command center in a covert manner. The BiCom device built by Trex Communications provides laser ranging, azimuth and elevation angle to a target, GPS position information, data storage and transmit capability, and full duplex audio transmission capability, all in a 3 kg hand held package. The communication channel utilizes an eye safe lasercom transceiver for covert voice or data transfer at 100 kbps at distances of up to 5 km. The information gathered electronically by the unit is sufficient to calculate the actual GPS positions or military grid coordinates of the observed targets. Several dozen targets can be stored in memory for later transmission via lasercom. Field tests were conducted by US Army personnel to evaluate these units and compare the results with conventional means of target position determination and data transfer. A description of the system and results of these tests are presented.

  8. Discovery of safety biomarkers for atorvastatin in rat urine using mass spectrometry based metabolomics combined with global and targeted approach.

    PubMed

    Kumar, Bhowmik Salil; Lee, Young-Joo; Yi, Hong Jae; Chung, Bong Chul; Jung, Byung Hwa

    2010-02-19

    In order to develop a safety biomarker for atorvastatin, this drug was orally administrated to hyperlipidemic rats, and a metabolomic study was performed. Atorvastatin was given in doses of either 70 mg kg(-1) day(-1) or 250 mg kg(-1) day(-1) for a period of 7 days (n=4 for each group). To evaluate any abnormal effects of the drug, physiological and plasma biochemical parameters were measured and histopathological tests were carried out. Safety biomarkers were derived by comparing these parameters and using both global and targeted metabolic profiling. Global metabolic profiling was performed using liquid chromatography/time of flight/mass spectrometry (LC/TOF/MS) with multivariate data analysis. Several safety biomarker candidates that included various steroids and amino acids were discovered as a result of global metabolic profiling, and they were also confirmed by targeted metabolic profiling using gas chromatography/mass spectrometry (GC/MS) and capillary electrophoresis/mass spectrometry (CE/MS). Serum biochemical and histopathological tests were used to detect abnormal drug reactions in the liver after repeating oral administration of atorvastatin. The metabolic differences between control and the drug-treated groups were compared using PLS-DA score plots. These results were compared with the physiological and plasma biochemical parameters and the results of a histopathological test. Estrone, cortisone, proline, cystine, 3-ureidopropionic acid and histidine were proposed as potential safety biomarkers related with the liver toxicity of atorvastatin. These results indicate that the combined application of global and targeted metabolic profiling could be a useful tool for the discovery of drug safety biomarkers. Copyright 2009 Elsevier B.V. All rights reserved.

  9. Imbalanced target prediction with pattern discovery on clinical data repositories.

    PubMed

    Chan, Tak-Ming; Li, Yuxi; Chiau, Choo-Chiap; Zhu, Jane; Jiang, Jie; Huo, Yong

    2017-04-20

    Clinical data repositories (CDR) have great potential to improve outcome prediction and risk modeling. However, most clinical studies require careful study design, dedicated data collection efforts, and sophisticated modeling techniques before a hypothesis can be tested. We aim to bridge this gap, so that clinical domain users can perform first-hand prediction on existing repository data without complicated handling, and obtain insightful patterns of imbalanced targets for a formal study before it is conducted. We specifically target for interpretability for domain users where the model can be conveniently explained and applied in clinical practice. We propose an interpretable pattern model which is noise (missing) tolerant for practice data. To address the challenge of imbalanced targets of interest in clinical research, e.g., deaths less than a few percent, the geometric mean of sensitivity and specificity (G-mean) optimization criterion is employed, with which a simple but effective heuristic algorithm is developed. We compared pattern discovery to clinically interpretable methods on two retrospective clinical datasets. They contain 14.9% deaths in 1 year in the thoracic dataset and 9.1% deaths in the cardiac dataset, respectively. In spite of the imbalance challenge shown on other methods, pattern discovery consistently shows competitive cross-validated prediction performance. Compared to logistic regression, Naïve Bayes, and decision tree, pattern discovery achieves statistically significant (p-values < 0.01, Wilcoxon signed rank test) favorable averaged testing G-means and F1-scores (harmonic mean of precision and sensitivity). Without requiring sophisticated technical processing of data and tweaking, the prediction performance of pattern discovery is consistently comparable to the best achievable performance. Pattern discovery has demonstrated to be robust and valuable for target prediction on existing clinical data repositories with imbalance and noise. The prediction results and interpretable patterns can provide insights in an agile and inexpensive way for the potential formal studies.

  10. A thin gold coated hydrogen heat pipe-cryogenic target for external experiments at COSY

    NASA Astrophysics Data System (ADS)

    Abdel-Bary, M.; Abdel-Samad, S.; Elawadi, G. A.; Kilian, K.; Ritman, J.

    2009-05-01

    A gravity assisted Gold coated heat pipe (GCHP) with 5-mm diameter has been developed and tested to cool a liquid hydrogen target for external beam experiments at COSY. The need for a narrow target diameter leads us to study the effect of reducing the heat pipe diameter to 5 mm instead of 7 mm, to study the effect of coating the external surface of the heat pipe by a shiny gold layer (to decrease the radiation heat load), and to study the effect of using the heat pipe without using 20 layers of' super-insulation around it (aluminized Mylar foil) to keep the target diameter as small as possible. The developed gold coated heat pipe was tested with 20 layers of super-insulation (WI) and without super-insulation (WOI). The operating characteristics for both conditions were compared to show the advantages and disadvantages.

  11. Cost-effectiveness of precision medicine in the fourth-line treatment of metastatic lung adenocarcinoma: An early decision analytic model of multiplex targeted sequencing.

    PubMed

    Doble, Brett; John, Thomas; Thomas, David; Fellowes, Andrew; Fox, Stephen; Lorgelly, Paula

    2017-05-01

    To identify parameters that drive the cost-effectiveness of precision medicine by comparing the use of multiplex targeted sequencing (MTS) to select targeted therapy based on tumour genomic profiles to either no further testing with chemotherapy or no further testing with best supportive care in the fourth-line treatment of metastatic lung adenocarcinoma. A combined decision tree and Markov model to compare costs, life-years, and quality-adjusted life-years over a ten-year time horizon from an Australian healthcare payer perspective. Data sources included the published literature and a population-based molecular cohort study (Cancer 2015). Uncertainty was assessed using deterministic sensitivity analyses and quantified by estimating expected value of perfect/partial perfect information. Uncertainty due to technological/scientific advancement was assessed through a number of plausible future scenario analyses. Point estimate incremental cost-effective ratios indicate that MTS is not cost-effective for selecting fourth-line treatment of metastatic lung adenocarcinoma. Lower mortality rates during testing and for true positive patients, lower health state utility values for progressive disease, and targeted therapy resulting in reductions in inpatient visits, however, all resulted in more favourable cost-effectiveness estimates for MTS. The expected value to decision makers of removing all current decision uncertainty was estimated to be between AUD 5,962,843 and AUD 13,196,451, indicating that additional research to reduce uncertainty may be a worthwhile investment. Plausible future scenarios analyses revealed limited improvements in cost-effectiveness under scenarios of improved test performance, decreased costs of testing/interpretation, and no biopsy costs/adverse events. Reductions in off-label targeted therapy costs, when considered together with the other scenarios did, however, indicate more favourable cost-effectiveness of MTS. As more clinical evidence is generated for MTS, the model developed should be revisited and cost-effectiveness re-estimated under different testing scenarios to further understand the value of precision medicine and its potential impact on the overall health budget. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Comparative evaluation of ethanolic extracts of Bacopa monnieri, Evolvulus alsinoides, Tinospora cordifolia and their combinations on cognitive functions in rats.

    PubMed

    Gupta, Avneet; Raj, Hem; Karchuli, Manvender Singh; Upmanyu, Neeraj

    2013-12-01

    The effects of ethanolic extracts of whole plants of Bacopa monnieri (BME), Evolvulus alsinoides (EAE), Tinospora cordifolia (TCE) and their combinations in equal proportion [CEP-1 (BME+EAE), CEP-2 (BME+TCE), CEP-3 (EAE+TCE) and CEP-4 (BME+EAE+TCE)] were tested in amnesic rats using Radial arm maze task performance (RAM) and Barnes maze test at 200 mg/kg p.o. The latency to find food and target hole was observed in RAM and Barnes maze respectively. Cognitive dysfunction was induced by scopolamine (0.3 mg/kg i.p.) treatment. BME, EAE, TCE and their combinations of equal proportion (CEPs) showed significant decrease in latency to find food and target hole in RAM and Barnes maze respectively. Inter comparison among single extract alone treated groups revealed that BME treated animals showed significant difference as compared to EAE and TCE treated animals. All combinations of equal proportion (CEPs) of these extracts showed significant difference in latency to find food and target hole as compared to single extracts treated animals. CEP-1 showed significantly better effect as compared to CEP-2 and CEP-3. Significant difference in latency to find food and target hole was also present between CEP-2 and CEP-3. Effect of CEP-4 was found to be significantly better than CEP-1, CEP-2 and CEP-3 treated rats in both models. From present investigation, it was concluded that ethanolic extract of Bacopa monnieri, Evolvulus alsinoides and Tinospora cordifolia provided better nootropic effect when used in combination.

  13. The impact of nurse-driven targeted HIV screening in 8 emergency departments: study protocol for the DICI-VIH cluster-randomized two-period crossover trial.

    PubMed

    Leblanc, Judith; Rousseau, Alexandra; Hejblum, Gilles; Durand-Zaleski, Isabelle; de Truchis, Pierre; Lert, France; Costagliola, Dominique; Simon, Tabassome; Crémieux, Anne-Claude

    2016-02-01

    In 2010, to reduce late HIV diagnosis, the French national health agency endorsed non-targeted HIV screening in health care settings. Despite these recommendations, non-targeted screening has not been implemented and only physician-directed diagnostic testing is currently performed. A survey conducted in 2010 in 29 French Emergency Departments (EDs) showed that non-targeted nurse-driven screening was feasible though only a few new HIV diagnoses were identified, predominantly among high-risk groups. A strategy targeting high-risk groups combined with current practice could be shown to be feasible, more efficient and cost-effective than current practice alone. DICI-VIH (acronym for nurse-driven targeted HIV screening) is a multicentre, cluster-randomized, two-period crossover trial. The primary objective is to compare the effectiveness of 2 strategies for diagnosing HIV among adult patients visiting EDs: nurse-driven targeted HIV screening combined with current practice (physician-directed diagnostic testing) versus current practice alone. Main secondary objectives are to compare access to specialist consultation and how early HIV diagnosis occurs in the course of the disease between the 2 groups, and to evaluate the implementation, acceptability and cost-effectiveness of nurse-driven targeted screening. The 2 strategies take place during 2 randomly assigned periods in 8 EDs of metropolitan Paris, where 42 % of France's new HIV patients are diagnosed every year. All patients aged 18 to 64, not presenting secondary to HIV exposure are included. During the intervention period, patients are invited to fill a 7-item questionnaire (country of birth, sexual partners and injection drug use) in order to select individuals who are offered a rapid test. If the rapid test is reactive, a follow-up visit with an infectious disease specialist is scheduled within 72 h. Assuming an 80 % statistical power and a 5 % type 1 error, with 1.04 and 3.38 new diagnoses per 10,000 patients in the control and targeted groups respectively, a sample size of 140,000 patients was estimated corresponding to 8,750 patients per ED and per period. Inclusions started in June 2014. Results are expected by mid-2016. The DICI-VIH study is the first large randomized controlled trial designed to assess nurse-driven targeted HIV screening. This study can provide valuable information on HIV screening in health care settings. ClinicalTrials.gov: NCT02127424 (29 April 2014).

  14. Effect of motion on speech recognition.

    PubMed

    Davis, Timothy J; Grantham, D Wesley; Gifford, René H

    2016-07-01

    The benefit of spatial separation for talkers in a multi-talker environment is well documented. However, few studies have examined the effect of talker motion on speech recognition. In the current study, we evaluated the effects of (1) motion of the target or distracters, (2) a priori information about the target and distracter spatial configurations, and (3) target and distracter location. In total, seventeen young adults with normal hearing were tested in a large anechoic chamber in two experiments. In Experiment 1, seven stimulus conditions were tested using the Coordinate Response Measure (Bolia et al., 2000) speech corpus, in which subjects were required to report the key words in a target sentence presented simultaneously with two distracter sentences. As in previous studies, there was a significant improvement in key word identification for conditions in which the target and distracters were spatially separated as compared to the co-located conditions. In addition, 1) motion of either talker or distracter resulted in improved performance compared to stationary presentation (talker motion yielded significantly better performance than distracter motion) 2) a priori information regarding stimulus configuration was not beneficial, and 3) performance was significantly better with key words at 0° azimuth as compared to -60° (on the listener's left). Experiment 2 included two additional conditions designed to assess whether the benefit of motion observed in Experiment 1 was due to the motion itself or to the fact that the motion conditions introduced small spatial separations in the target and distracter key words. Results showed that small spatial separations (on the order of 5-8°) resulted in improved performance (relative to co-located key words) whether the sentences were moving or stationary. These results suggest that in the presence of distracting messages, motion of either target or distracters and/or small spatial separation of the key words may be beneficial for sound source segregation and thus for improved speech recognition. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. The Effects of Sleep on Emotional Target Detection Performance: A Novel iPad-Based Pediatric Game

    PubMed Central

    Colonna, Annalisa; Smith, Anna B.; Smith, Stuart; VanDenEshof, Kirandeep; Orgill, Jane; Gringras, Paul; Pal, Deb K.

    2018-01-01

    Background: Consolidation of learning occurs during sleep but when it is disturbed there may be an adverse impact upon these functions. While research has focused upon how sleep affects cognition in adulthood, the effects of disrupted sleep are likely to impact more heavily on learning among children and adolescents. We aimed to investigate whether a night’s sleep impacts upon executive function compared with an equivalent wakefulness period. We also wanted to know whether restricting sleep would reduce these effects on performance. To investigate this issue in children, we adapted existing research methods to make them more suitable for this population. Methods: Using a cross-over trial design, 22 children aged 7–14 completed an updated but previously validated, continuous performance task (CPT) designed to be appealing to children, containing emotional and neutral targets and presented on an iPad. We measured omission and commission errors, mean and variability of reaction times (RTs) immediately and after a delay spent in the following three ways: 11-h intervals of unrestricted and restricted sleep in the style of a ‘sleepover’ and daytime wakefulness. We examined differences in immediate and delayed testing for each dependent variable. Both sleep nights were spent in a specialist sleep lab where polysomnography data were recorded. Results: While there were no significant main effects of sleep condition, as expected we observed significantly faster and more accurate performance in delayed compared with immediate testing across all conditions for omission errors, RT and variability of RT. Importantly, we saw a significant interaction for commission errors to emotional targets (p = 0.034): while they were comparable across all conditions during immediate testing, for delayed testing there were significantly more errors after wakefulness compared with unrestricted sleep (p = 0.019) and at a trend level for restricted sleep (p = 0.063). Performance improvement after restricted sleep was inversely correlated with sleep opportunity time (p = 0.03), total sleep time (p = 0.01) and total non-REM time (p = 0.005). Conclusion: This tool, designed to be simple to use and appealing to children, revealed a preserving effect of typical and disrupted sleep periods on performance during an emotionally themed target detection task compared with an equivalent wakefulness period. PMID:29563887

  16. Addition of atropine to submaximal exercise stress testing in patients evaluated for suspected ischaemia with SPECT imaging: a randomized, placebo-controlled trial.

    PubMed

    Manganelli, Fiore; Spadafora, Marco; Varrella, Paola; Peluso, Giuseppina; Sauro, Rosario; Di Lorenzo, Emilio; Rosato, Giuseppe; Daniele, Stefania; Cuocolo, Alberto

    2011-02-01

    To evaluate the effects of the addition of atropine to exercise testing in patients who failed to achieve their target heart rate (HR) during stress myocardial perfusion imaging with single-photon emission computed tomography (SPECT). The study was a prospective, randomized, placebo-controlled design. Patients with suspected or known coronary artery disease who failed to achieve a target HR (≥85% of maximal predicted HR) during exercise SPECT imaging were randomized to receive intravenous atropine (n=100) or placebo (n=101). The two groups of patients did not differ with respect to demographic or clinical characteristics. A higher proportion of patients in the atropine group achieved the target HR compared to the placebo group (60% versus 3%, p<0.0001). SPECT imaging was abnormal in a higher proportion of patients in the atropine group as compared to the placebo group (57% versus 42%, p<0.05). Stress-induced myocardial ischaemia was present in more patients in the atropine group as compared to placebo (47% versus 29%, p<0.01). In both groups of patients, no major side effects occurred. The addition of atropine at the end of exercise testing is more effective than placebo in raising HR to adequate levels, without additional risks of complications. The use of atropine in patients who initially failed to achieve their maximal predicted HR is associated with a higher probability of achieving a diagnostic myocardial perfusion study.

  17. Videogrammetry Using Projected Circular Targets: Proof-of-Concept Test

    NASA Technical Reports Server (NTRS)

    Pappa, Richard S.; Black, Jonathan T.

    2003-01-01

    Videogrammetry is the science of calculating 3D object coordinates as a function of time from image sequences. It expands the method of photogrammetry to multiple time steps enabling the object to be characterized dynamically. Photogrammetry achieves the greatest accuracy with high contrast, solid-colored, circular targets. The high contrast is most often effected using retro-reflective targets attached to the measurement article. Knowledge of the location of each target allows those points to be tracked in a sequence of images, thus yielding dynamic characterization of the overall object. For ultra-lightweight and inflatable gossamer structures (e.g. solar sails, inflatable antennae, sun shields, etc.) where it may be desirable to avoid physically attaching retro-targets, a high-density grid of projected circular targets - called dot projection - is a viable alternative. Over time the object changes shape or position independently of the dots. Dynamic behavior, such as deployment or vibration, can be characterized by tracking the overall 3D shape of the object instead of tracking specific object points. To develop this method, an oscillating rigid object was measured using both retroreflective targets and dot projection. This paper details these tests, compares the results, and discusses the overall accuracy of dot projection videogrammetry.

  18. Videogrammetry Using Projected Circular Targets: Proof-of-Concept Test

    NASA Technical Reports Server (NTRS)

    Black, Jonathan T.; Pappa, Richard S.

    2003-01-01

    Videogrammetry is the science of calculating 3D object coordinates as a function of time from image sequences. It expands the method of photogrammetry to multiple time steps enabling the object to be characterized dynamically. Photogrammetry achieves the greatest accuracy with high contrast, solid-colored circular targets. The high contrast is most often effected using retro-reflective targets attached to the measurement article. Knowledge of the location of each target allows those points to be tracked in a sequence of images, thus yielding dynamic characterization of the overall object. For ultra-lightweight and inflatable gossamer structures (e.g. solar sails, inflatable antennae, sun shields, etc.) where it may be desirable to avoid physically attaching retro-targets, a high-density grid of projected circular targets - called dot projection - is a viable alternative. Over time the object changes shape or position independently of the dots. Dynamic behavior, such as deployment or vibration, can be characterized by tracking the overall 3D shape of the object instead of tracking specific object points. To develop this method, an oscillating rigid object was measured using both retro- reflective targets and dot projection. This paper details these tests, compares the results, and discusses the overall accuracy of dot projection videogrammetry.

  19. Penetration analysis of projectile with inclined concrete target

    NASA Astrophysics Data System (ADS)

    Kim, S. B.; Kim, H. W.; Yoo, Y. H.

    2015-09-01

    This paper presents numerical analysis result of projectile penetration with concrete target. We applied dynamic material properties of 4340 steels, aluminium and explosive for projectile body. Dynamic material properties were measured with static tensile testing machine and Hopkinson pressure bar tests. Moreover, we used three concrete damage models included in LS-DYNA 3D, such as SOIL_CONCRETE, CSCM (cap model with smooth interaction) and CONCRETE_DAMAGE (K&C concrete) models. Strain rate effect for concrete material is important to predict the fracture deformation and shape of concrete, and penetration depth for projectiles. CONCRETE_DAMAGE model with strain rate effect also applied to penetration analysis. Analysis result with CSCM model shows good agreement with penetration experimental data. The projectile trace and fracture shapes of concrete target were compared with experimental data.

  20. Determinants of Disagreement in Personality Descriptions.

    ERIC Educational Resources Information Center

    Prytulak, Susan Pepper

    The description of, or formation of impressions about, persons are viewed as being dependent on situational context and the standard or reference point to which the persons are compared. A study is described in which different subject groups compared a target's score on a "cautiousness-boldness" or a "relaxation-alertness" test with either a…

  1. Differences in Self-Disclosure Patterns among Americans versus Chinese: A Comparative Study.

    ERIC Educational Resources Information Center

    Chen, Guo-Ming

    A study investigated differences in self-disclosure, comparing patterns in Americans versus Chinese. Subjects, 198 American college students and 146 Chinese (Taiwan) students studying in the United States, completed a 200-item self-disclosure chart to target persons on special topics. Results of t-tests and analysis of variance indicated that…

  2. Comparison of human observer and algorithmic target detection in nonurban forward-looking infrared imagery

    NASA Astrophysics Data System (ADS)

    Weber, Bruce A.

    2005-07-01

    We have performed an experiment that compares the performance of human observers with that of a robust algorithm for the detection of targets in difficult, nonurban forward-looking infrared imagery. Our purpose was to benchmark the comparison and document performance differences for future algorithm improvement. The scale-insensitive detection algorithm, used as a benchmark by the Night Vision Electronic Sensors Directorate for algorithm evaluation, employed a combination of contrastlike features to locate targets. Detection receiver operating characteristic curves and observer-confidence analyses were used to compare human and algorithmic responses and to gain insight into differences. The test database contained ground targets, in natural clutter, whose detectability, as judged by human observers, ranged from easy to very difficult. In general, as compared with human observers, the algorithm detected most of the same targets, but correlated confidence with correct detections poorly and produced many more false alarms at any useful level of performance. Though characterizing human performance was not the intent of this study, results suggest that previous observational experience was not a strong predictor of human performance, and that combining individual human observations by majority vote significantly reduced false-alarm rates.

  3. Additivity of nonsimultaneous masking for short Gaussian-shaped sinusoids.

    PubMed

    Laback, Bernhard; Balazs, Peter; Necciari, Thibaud; Savel, Sophie; Ystad, Solvi; Meunier, Sabine; Kronland-Martinet, Richard

    2011-02-01

    The additivity of nonsimultaneous masking was studied using Gaussian-shaped tone pulses (referred to as Gaussians) as masker and target stimuli. Combinations of up to four temporally separated Gaussian maskers with an equivalent rectangular bandwidth of 600 Hz and an equivalent rectangular duration of 1.7 ms were tested. Each masker was level-adjusted to produce approximately 8 dB of masking. Excess masking (exceeding linear additivity) was generally stronger than reported in the literature for longer maskers and comparable target levels. A model incorporating a compressive input/output function, followed by a linear summation stage, underestimated excess masking when using an input/output function derived from literature data for longer maskers and comparable target levels. The data could be predicted with a more compressive input/output function. Stronger compression may be explained by assuming that the Gaussian stimuli were too short to evoke the medial olivocochlear reflex (MOCR), whereas for longer maskers tested previously the MOCR caused reduced compression. Overall, the interpretation of the data suggests strong basilar membrane compression for very short stimuli.

  4. A new multi-spectral feature level image fusion method for human interpretation

    NASA Astrophysics Data System (ADS)

    Leviner, Marom; Maltz, Masha

    2009-03-01

    Various different methods to perform multi-spectral image fusion have been suggested, mostly on the pixel level. However, the jury is still out on the benefits of a fused image compared to its source images. We present here a new multi-spectral image fusion method, multi-spectral segmentation fusion (MSSF), which uses a feature level processing paradigm. To test our method, we compared human observer performance in a three-task experiment using MSSF against two established methods: averaging and principle components analysis (PCA), and against its two source bands, visible and infrared. The three tasks that we studied were: (1) simple target detection, (2) spatial orientation, and (3) camouflaged target detection. MSSF proved superior to the other fusion methods in all three tests; MSSF also outperformed the source images in the spatial orientation and camouflaged target detection tasks. Based on these findings, current speculation about the circumstances in which multi-spectral image fusion in general and specific fusion methods in particular would be superior to using the original image sources can be further addressed.

  5. Performance of resonant radar target identification algorithms using intra-class weighting functions

    NASA Astrophysics Data System (ADS)

    Mustafa, A.

    The use of calibrated resonant-region radar cross section (RCS) measurements of targets for the classification of large aircraft is discussed. Errors in the RCS estimate of full scale aircraft flying over an ocean, introduced by the ionospheric variability and the sea conditions were studied. The Weighted Target Representative (WTR) classification algorithm was developed, implemented, tested and compared with the nearest neighbor (NN) algorithm. The WTR-algorithm has a low sensitivity to the uncertainty in the aspect angle of the unknown target returns. In addition, this algorithm was based on the development of a new catalog of representative data which reduces the storage requirements and increases the computational efficiency of the classification system compared to the NN-algorithm. Experiments were designed to study and evaluate the characteristics of the WTR- and the NN-algorithms, investigate the classifiability of targets and study the relative behavior of the number of misclassifications as a function of the target backscatter features. The classification results and statistics were shown in the form of performance curves, performance tables and confusion tables.

  6. Drivers' detection of roadside targets when driving vehicles with three headlight systems during high beam activation.

    PubMed

    Reagan, Ian J; Brumbelow, Matthew L

    2017-02-01

    A previous open-road experiment indicated that curve-adaptive HID headlights driven with low beams improved drivers' detection of low conspicuity targets compared with fixed halogen and fixed HID low beam systems. The current study used the same test environment and targets to assess whether drivers' detection of targets was affected by the same three headlight systems when using high beams. Twenty drivers search and responded for 60 8×12inch targets of high or low reflectance that were distributed evenly across straight and curved road sections as they drove at 30 mph on an unlit two-lane rural road. The results indicate that target detection performance was generally similar across the three systems. However, one interaction indicated that drivers saw low reflectance targets on straight road sections from further away when driving with the fixed halogen high beam condition compared with curve-adaptive HID high beam headlights and also indicated a possible benefit for the curve-adaptive HID high beams for high reflectance targets placed on the inside of curves. The results of this study conflict with the previous study of low beams, which showed a consistent benefit for the curve-adaptive HID low beams for targets placed on curves compared with fixed HID and fixed halogen low beam conditions. However, a comparison of mean detection distances from the two studies indicated uniformly longer mean target detection distances for participants driving with high beams and implicates the potential visibility benefits for systems that optimize proper high beam use. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Scene Configuration and Object Reliability Affect the Use of Allocentric Information for Memory-Guided Reaching

    PubMed Central

    Klinghammer, Mathias; Blohm, Gunnar; Fiehler, Katja

    2017-01-01

    Previous research has shown that egocentric and allocentric information is used for coding target locations for memory-guided reaching movements. Especially, task-relevance determines the use of objects as allocentric cues. Here, we investigated the influence of scene configuration and object reliability as a function of task-relevance on allocentric coding for memory-guided reaching. For that purpose, we presented participants images of a naturalistic breakfast scene with five objects on a table and six objects in the background. Six of these objects served as potential reach-targets (= task-relevant objects). Participants explored the scene and after a short delay, a test scene appeared with one of the task-relevant objects missing, indicating the location of the reach target. After the test scene vanished, participants performed a memory-guided reaching movement toward the target location. Besides removing one object from the test scene, we also shifted the remaining task-relevant and/or task-irrelevant objects left- or rightwards either coherently in the same direction or incoherently in opposite directions. By varying object coherence, we manipulated the reliability of task-relevant and task-irrelevant objects in the scene. In order to examine the influence of scene configuration (distributed vs. grouped arrangement of task-relevant objects) on allocentric coding, we compared the present data with our previously published data set (Klinghammer et al., 2015). We found that reaching errors systematically deviated in the direction of object shifts, but only when the objects were task-relevant and their reliability was high. However, this effect was substantially reduced when task-relevant objects were distributed across the scene leading to a larger target-cue distance compared to a grouped configuration. No deviations of reach endpoints were observed in conditions with shifts of only task-irrelevant objects or with low object reliability irrespective of task-relevancy. Moreover, when solely task-relevant objects were shifted incoherently, the variability of reaching endpoints increased compared to coherent shifts of task-relevant objects. Our results suggest that the use of allocentric information for coding targets for memory-guided reaching depends on the scene configuration, in particular the average distance of the reach target to task-relevant objects, and the reliability of task-relevant allocentric information. PMID:28450826

  8. Scene Configuration and Object Reliability Affect the Use of Allocentric Information for Memory-Guided Reaching.

    PubMed

    Klinghammer, Mathias; Blohm, Gunnar; Fiehler, Katja

    2017-01-01

    Previous research has shown that egocentric and allocentric information is used for coding target locations for memory-guided reaching movements. Especially, task-relevance determines the use of objects as allocentric cues. Here, we investigated the influence of scene configuration and object reliability as a function of task-relevance on allocentric coding for memory-guided reaching. For that purpose, we presented participants images of a naturalistic breakfast scene with five objects on a table and six objects in the background. Six of these objects served as potential reach-targets (= task-relevant objects). Participants explored the scene and after a short delay, a test scene appeared with one of the task-relevant objects missing, indicating the location of the reach target. After the test scene vanished, participants performed a memory-guided reaching movement toward the target location. Besides removing one object from the test scene, we also shifted the remaining task-relevant and/or task-irrelevant objects left- or rightwards either coherently in the same direction or incoherently in opposite directions. By varying object coherence, we manipulated the reliability of task-relevant and task-irrelevant objects in the scene. In order to examine the influence of scene configuration (distributed vs. grouped arrangement of task-relevant objects) on allocentric coding, we compared the present data with our previously published data set (Klinghammer et al., 2015). We found that reaching errors systematically deviated in the direction of object shifts, but only when the objects were task-relevant and their reliability was high. However, this effect was substantially reduced when task-relevant objects were distributed across the scene leading to a larger target-cue distance compared to a grouped configuration. No deviations of reach endpoints were observed in conditions with shifts of only task-irrelevant objects or with low object reliability irrespective of task-relevancy. Moreover, when solely task-relevant objects were shifted incoherently, the variability of reaching endpoints increased compared to coherent shifts of task-relevant objects. Our results suggest that the use of allocentric information for coding targets for memory-guided reaching depends on the scene configuration, in particular the average distance of the reach target to task-relevant objects, and the reliability of task-relevant allocentric information.

  9. Flexor bias of joint position in humans during spaceflight

    NASA Technical Reports Server (NTRS)

    McCall, G. E.; Goulet, C.; Boorman, G. I.; Roy, R. R.; Edgerton, V. R.

    2003-01-01

    The ability to estimate ankle and elbow joint position was tested before, during, and after a 17-day spaceflight. Subjects estimated targeted joint angles during isovelocity (IsoV) joint movements with agonist muscle groups either active or relaxed. These movements included elbow extension (EE) and elbow flexion (EF), and plantarflexion (PF) and dorsiflexion (DF) of the ankle. Subjects also estimated these joint positions while moving the dynamometer at their chosen (variable) velocity (VarV) during EE and PF. For IsoV tests, no differences were observed between active and passive movements for either the ankle or elbow. Compared with those of pre-flight test days, estimates of targeted elbow joint angles were approximately 5 degrees to 15 degrees more flexed in-flight, and returned toward the pre-flight values during recovery. The spaceflight effects for the ankle were inconsistent and less prevalent than those for the elbow. The VarV PF test condition for the 120 degrees target angle at the ankle exhibited approximately 5 degrees to 7 degrees more DF target angle estimates in-flight compared with those pre- or post-flight. In contrast, during IsoV PF there was a tendency for ankle estimates to be approximately 2 degrees to 3 degrees more PF after 2-3 days exposure to spaceflight. These data indicate that during spaceflight the perception of elbow extension is greater than actuality, and are consistent with the interpretation that microgravity induced a flexor bias in the estimation of the actual elbow joint position. Moreover, these effects in joint proprioception during spaceflight were observed in individual isolated single-joint movements during tasks in which vestibular function in maintaining posture were minimal.

  10. Flexor bias of joint position in humans during spaceflight.

    PubMed

    McCall, G E; Goulet, C; Boorman, G I; Roy, R R; Edgerton, V R

    2003-09-01

    The ability to estimate ankle and elbow joint position was tested before, during, and after a 17-day spaceflight. Subjects estimated targeted joint angles during isovelocity (IsoV) joint movements with agonist muscle groups either active or relaxed. These movements included elbow extension (EE) and elbow flexion (EF), and plantarflexion (PF) and dorsiflexion (DF) of the ankle. Subjects also estimated these joint positions while moving the dynamometer at their chosen (variable) velocity (VarV) during EE and PF. For IsoV tests, no differences were observed between active and passive movements for either the ankle or elbow. Compared with those of pre-flight test days, estimates of targeted elbow joint angles were approximately 5 degrees to 15 degrees more flexed in-flight, and returned toward the pre-flight values during recovery. The spaceflight effects for the ankle were inconsistent and less prevalent than those for the elbow. The VarV PF test condition for the 120 degrees target angle at the ankle exhibited approximately 5 degrees to 7 degrees more DF target angle estimates in-flight compared with those pre- or post-flight. In contrast, during IsoV PF there was a tendency for ankle estimates to be approximately 2 degrees to 3 degrees more PF after 2-3 days exposure to spaceflight. These data indicate that during spaceflight the perception of elbow extension is greater than actuality, and are consistent with the interpretation that microgravity induced a flexor bias in the estimation of the actual elbow joint position. Moreover, these effects in joint proprioception during spaceflight were observed in individual isolated single-joint movements during tasks in which vestibular function in maintaining posture were minimal.

  11. Epitope Mapping of Avian Influenza M2e Protein: Different Species Recognise Various Epitopes

    PubMed Central

    Hasan, Noor Haliza; Ignjatovic, Jagoda; Tarigan, Simson; Peaston, Anne; Hemmatzadeh, Farhid

    2016-01-01

    A common approach for developing diagnostic tests for influenza virus detection is the use of mouse or rabbit monoclonal and/or polyclonal antibodies against a target antigen of the virus. However, comparative mapping of the target antigen using antibodies from different animal sources has not been evaluated before. This is important because identification of antigenic determinants of the target antigen in different species plays a central role to ensure the efficiency of a diagnostic test, such as competitive ELISA or immunohistochemistry-based tests. Interest in the matrix 2 ectodomain (M2e) protein of avian influenza virus (AIV) as a candidate for a universal vaccine and also as a marker for detection of virus infection in vaccinated animals (DIVA) is the rationale for the selection of this protein for comparative mapping evaluation. This study aimed to map the epitopes of the M2e protein of avian influenza virus H5N1 using chicken, mouse and rabbit monoclonal or monospecific antibodies. Our findings revealed that rabbit antibodies (rAbs) recognized epitope 6EVETPTRN13 of the M2e, located at the N-terminal of the protein, while mouse (mAb) and chicken antibodies (cAbs) recognized epitope 10PTRNEWECK18, located at the centre region of the protein. The findings highlighted the difference between the M2e antigenic determinants recognized by different species that emphasized the importance of comparative mapping of antibody reactivity from different animals to the same antigen, especially in the case of multi-host infectious agents such as influenza. The findings are of importance for antigenic mapping, as well as diagnostic test and vaccine development. PMID:27362795

  12. Efficacy and Ecotoxicity of Novel Anti-Fouling Nanomaterials in Target and Non-Target Marine Species.

    PubMed

    Avelelas, Francisco; Martins, Roberto; Oliveira, Tânia; Maia, Frederico; Malheiro, Eliana; Soares, Amadeu M V M; Loureiro, Susana; Tedim, João

    2017-04-01

    Biofouling is a global problem that affects virtually all the immersed structures. Currently, several novel environmentally friendly approaches are being tested worldwide to decrease the toxicity of biocides in non-fouling species, such as the encapsulation/immobilization of commercially available biocides, in order to achieve control over the leaching rate. The present study addresses the toxicity of two widely used booster biocides, zinc pyrithione (ZnPT) and copper pyrithione (CuPT), in its free and incorporated forms in order to assess their toxicity and anti-fouling efficacy in target and non-target species. To achieve this goal, the following marine organisms were tested; the green microalgae Tetraselmis chuii (non-target species) and both target species, the diatom Phaeodactylum tricornutum and the mussel Mytilus edulis. Organisms were exposed to both biocides, two unloaded nanostructured materials and nanomaterials loaded with biocides, from 10 μg/L to 100 mg/L total weight, following standard protocols. The most eco-friendly and simultaneously efficient anti-fouling solution against the two photosynthetic species (nanoclays loaded with ZnPT) was then tested on mussels to assess its lethal efficacy (LC 50  = 123 μg/L) and compared with free biocide (LC 50  = 211 μg/L) and unloaded material (LC 50  > 1000 μg/L). A second exposure test with sub-lethal concentrations (lower than 100 μg/L), using mussels, was carried out to assess biochemical changes caused by the tested compounds. Oxidative stress, detoxification and neurotransmission markers were not responsive; however, different antioxidant patterns were found with free ZnPT and loaded nanoclay exposures. Thus, the immobilization of the biocide ZnPT into nanoclays proved to be a promising efficient and eco-friendly anti-fouling strategy.

  13. Comparative statistical component analysis of transgenic, cyanophycin-producing potatoes in greenhouse and field trials.

    PubMed

    Schmidt, Kerstin; Schmidtke, Jörg; Mast, Yvonne; Waldvogel, Eva; Wohlleben, Wolfgang; Klemke, Friederike; Lockau, Wolfgang; Hausmann, Tina; Hühns, Maja; Broer, Inge

    2017-08-01

    Potatoes are a promising system for industrial production of the biopolymer cyanophycin as a second compound in addition to starch. To assess the efficiency in the field, we analysed the stability of the system, specifically its sensitivity to environmental factors. Field and greenhouse trials with transgenic potatoes (two independent events) were carried out for three years. The influence of environmental factors was measured and target compounds in the transgenic plants (cyanophycin, amino acids) were analysed for differences to control plants. Furthermore, non-target parameters (starch content, number, weight and size of tubers) were analysed for equivalence with control plants. The huge amount of data received was handled using modern statistical approaches to model the correlation between influencing environmental factors (year of cultivation, nitrogen fertilization, origin of plants, greenhouse or field cultivation) and key components (starch, amino acids, cyanophycin) and agronomic characteristics. General linear models were used for modelling, and standard effect sizes were applied to compare conventional and genetically modified plants. Altogether, the field trials prove that significant cyanophycin production is possible without reduction of starch content. Non-target compound composition seems to be equivalent under varying environmental conditions. Additionally, a quick test to measure cyanophycin content gives similar results compared to the extensive enzymatic test. This work facilitates the commercial cultivation of cyanophycin potatoes.

  14. Exploring ambivalence in motivational interviewing with obese African American adolescents and their caregivers: A mixed methods analysis

    PubMed Central

    Carcone, April Idalski; Barton, Ellen; Eggly, Susan; Brogan Hartlieb, Kathryn E.; Thominet, Luke; Naar, Sylvie

    2016-01-01

    Objective We conducted an exploratory mixed methods study to describe the ambivalence African-American adolescents and their caregivers expressed during motivational interviewing sessions targeting weight loss. Methods We extracted ambivalence statements from 37 previously coded counseling sessions. We used directed content analysis to categorize ambivalence related to the target behaviors of nutrition, activity, or weight. We compared adolescent-caregiver dyads’ ambivalence using the paired sample t-test and Wilcoxon signed-rank test. We then used conventional content analysis to compare the specific content of adolescents’ and caregivers’ ambivalence statements. Results Adolescents and caregivers expressed the same number of ambivalence statements overall, related to activity and weight, but caregivers expressed more statements about nutrition. Content analysis revealed convergences and divergences in caregivers’ and adolescents’ ambivalence about weight loss. Conclusion Understanding divergences in adolescent-caregiver ambivalence about the specific behaviors to target may partially explain the limited success of family-based weight loss interventions targeting African American families and provides a unique opportunity for providers to enhance family communication, foster teamwork, and build self-efficacy to promote behavior change. Practice implications Clinicians working in family contexts should explore how adolescents and caregivers converge and diverge in their ambivalence in order to recommend weight loss strategies that best meet families’ needs. PMID:26916012

  15. An improved multi-domain convolution tracking algorithm

    NASA Astrophysics Data System (ADS)

    Sun, Xin; Wang, Haiying; Zeng, Yingsen

    2018-04-01

    Along with the wide application of the Deep Learning in the field of Computer vision, Deep learning has become a mainstream direction in the field of object tracking. The tracking algorithm in this paper is based on the improved multidomain convolution neural network, and the VOT video set is pre-trained on the network by multi-domain training strategy. In the process of online tracking, the network evaluates candidate targets sampled from vicinity of the prediction target in the previous with Gaussian distribution, and the candidate target with the highest score is recognized as the prediction target of this frame. The Bounding Box Regression model is introduced to make the prediction target closer to the ground-truths target box of the test set. Grouping-update strategy is involved to extract and select useful update samples in each frame, which can effectively prevent over fitting. And adapt to changes in both target and environment. To improve the speed of the algorithm while maintaining the performance, the number of candidate target succeed in adjusting dynamically with the help of Self-adaption parameter Strategy. Finally, the algorithm is tested by OTB set, compared with other high-performance tracking algorithms, and the plot of success rate and the accuracy are drawn. which illustrates outstanding performance of the tracking algorithm in this paper.

  16. Targeted Re-Sequencing Emulsion PCR Panel for Myopathies: Results in 94 Cases.

    PubMed

    Punetha, Jaya; Kesari, Akanchha; Uapinyoying, Prech; Giri, Mamta; Clarke, Nigel F; Waddell, Leigh B; North, Kathryn N; Ghaoui, Roula; O'Grady, Gina L; Oates, Emily C; Sandaradura, Sarah A; Bönnemann, Carsten G; Donkervoort, Sandra; Plotz, Paul H; Smith, Edward C; Tesi-Rocha, Carolina; Bertorini, Tulio E; Tarnopolsky, Mark A; Reitter, Bernd; Hausmanowa-Petrusewicz, Irena; Hoffman, Eric P

    2016-05-27

    Molecular diagnostics in the genetic myopathies often requires testing of the largest and most complex transcript units in the human genome (DMD, TTN, NEB). Iteratively targeting single genes for sequencing has traditionally entailed high costs and long turnaround times. Exome sequencing has begun to supplant single targeted genes, but there are concerns regarding coverage and needed depth of the very large and complex genes that frequently cause myopathies. To evaluate efficiency of next-generation sequencing technologies to provide molecular diagnostics for patients with previously undiagnosed myopathies. We tested a targeted re-sequencing approach, using a 45 gene emulsion PCR myopathy panel, with subsequent sequencing on the Illumina platform in 94 undiagnosed patients. We compared the targeted re-sequencing approach to exome sequencing for 10 of these patients studied. We detected likely pathogenic mutations in 33 out of 94 patients with a molecular diagnostic rate of approximately 35%. The remaining patients showed variants of unknown significance (35/94 patients) or no mutations detected in the 45 genes tested (26/94 patients). Mutation detection rates for targeted re-sequencing vs. whole exome were similar in both methods; however exome sequencing showed better distribution of reads and fewer exon dropouts. Given that costs of highly parallel re-sequencing and whole exome sequencing are similar, and that exome sequencing now takes considerably less laboratory processing time than targeted re-sequencing, we recommend exome sequencing as the standard approach for molecular diagnostics of myopathies.

  17. Target recognition and phase acquisition by using incoherent digital holographic imaging

    NASA Astrophysics Data System (ADS)

    Lee, Munseob; Lee, Byung-Tak

    2017-05-01

    In this study, we proposed the Incoherent Digital Holographic Imaging (IDHI) for recognition and phase information of dedicated target. Although recent development of a number of target recognition techniques such as LIDAR, there have limited success in target discrimination, in part due to low-resolution, low scanning speed, and computation power. In the paper, the proposed system consists of the incoherent light source, such as LED, Michelson interferometer, and digital CCD for acquisition of four phase shifting image. First of all, to compare with relative coherence, we used a source as laser and LED, respectively. Through numerical reconstruction by using the four phase shifting method and Fresnel diffraction method, we recovered the intensity and phase image of USAF resolution target apart from about 1.0m distance. In this experiment, we show 1.2 times improvement in resolution compared to conventional imaging. Finally, to confirm the recognition result of camouflaged targets with the same color from background, we carry out to test holographic imaging in incoherent light. In this result, we showed the possibility of a target detection and recognition that used three dimensional shape and size signatures, numerical distance from phase information of obtained holographic image.

  18. Lateral Flow Assay Based on Paper-Hydrogel Hybrid Material for Sensitive Point-of-Care Detection of Dengue Virus.

    PubMed

    Choi, Jane Ru; Yong, Kar Wey; Tang, Ruihua; Gong, Yan; Wen, Ting; Yang, Hui; Li, Ang; Chia, Yook Chin; Pingguan-Murphy, Belinda; Xu, Feng

    2017-01-01

    Paper-based devices have been broadly used for the point-of-care detection of dengue viral nucleic acids due to their simplicity, cost-effectiveness, and readily observable colorimetric readout. However, their moderate sensitivity and functionality have limited their applications. Despite the above-mentioned advantages, paper substrates are lacking in their ability to control fluid flow, in contrast to the flow control enabled by polymer substrates (e.g., agarose) with readily tunable pore size and porosity. Herein, taking the benefits from both materials, the authors propose a strategy to create a hybrid substrate by incorporating agarose into the test strip to achieve flow control for optimal biomolecule interactions. As compared to the unmodified test strip, this strategy allows sensitive detection of targets with an approximately tenfold signal improvement. Additionally, the authors showcase the potential of functionality improvement by creating multiple test zones for semi-quantification of targets, suggesting that the number of visible test zones is directly proportional to the target concentration. The authors further demonstrate the potential of their proposed strategy for clinical assessment by applying it to their prototype sample-to-result test strip to sensitively and semi-quantitatively detect dengue viral RNA from the clinical blood samples. This proposed strategy holds significant promise for detecting various targets for diverse future applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Magnetic resonance/transrectal ultrasound fusion biopsy of the prostate compared to systematic 12-core biopsy for the diagnosis and characterization of prostate cancer: multi-institutional retrospective analysis of 389 patients.

    PubMed

    Mariotti, Guilherme C; Costa, Daniel N; Pedrosa, Ivan; Falsarella, Priscila M; Martins, Tatiana; Roehrborn, Claus G; Rofsky, Neil M; Xi, Yin; M Andrade, Thais C; Queiroz, Marcos R; Lotan, Yair; Garcia, Rodrigo G; Lemos, Gustavo C; Baroni, Ronaldo H

    2016-09-01

    To determine the incremental diagnostic value of targeted biopsies added to an extended sextant biopsy scheme on a per-patient, risk-stratified basis in 2 academic centers using different multiparametric magnetic resonance imaging (MRI) protocols, a large group of radiologists, multiple biopsy systems, and different biopsy operators. All patients with suspected prostate cancer (PCa) who underwent multiparametric MRI of the prostate in 2 academic centers between February 2013 and January 2015 followed by systematic and targeted MRI-transrectal ultrasound fusion biopsy were reviewed. Risk-stratified detection rate using systematic biopsies was compared with targeted biopsies on a per-patient basis. The McNemar test was used to compare diagnostic performance of the 2 approaches. A total of 389 men met eligibility criteria. PCa was diagnosed in 47% (182/389), 52%(202/389), and 60%(235/389) of patients using the targeted, systematic, and combined (targeted plus systematic) approach, respectively. Compared with systematic biopsy, targeted biopsy diagnosed 11% (37 vs. 26) more intermediate-to-high risk (P<0.0001) and 16% (10 vs. 16) fewer low-risk tumors (P<0.0001). These results were replicated when data from each center, biopsy-naïve patients, and men with previous negative biopsies were analyzed separately. Targeted MRI-transrectal ultrasound fusion biopsy consistently improved the detection of clinically significant PCa in a large patient cohort with diverse equipment, protocols, radiologists, and biopsy operators as can be encountered in clinical practice. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Identifying On-Orbit Test Targets for Space Fence Operational Testing

    NASA Astrophysics Data System (ADS)

    Pechkis, D.; Pacheco, N.; Botting, T.

    2014-09-01

    Space Fence will be an integrated system of two ground-based, S-band (2 to 4 GHz) phased-array radars located in Kwajalein and perhaps Western Australia [1]. Space Fence will cooperate with other Space Surveillance Network sensors to provide space object tracking and radar characterization data to support U.S. Strategic Command space object catalog maintenance and other space situational awareness needs. We present a rigorous statistical test design intended to test Space Fence to the letter of the program requirements as well as to characterize the system performance across the entire operational envelope. The design uses altitude, size, and inclination as independent factors in statistical tests of dependent variables (e.g., observation accuracy) linked to requirements. The analysis derives the type and number of necessary test targets. Comparing the resulting sample sizes with the number of currently known targets, we identify those areas where modelling and simulation methods are needed. Assuming hypothetical Kwajalein radar coverage and a conservative number of radar passes per object per day, we conclude that tests involving real-world space objects should take no more than 25 days to evaluate all operational requirements; almost 60 percent of the requirements can be tested in a single day and nearly 90 percent can be tested in one week or less. Reference: [1] L. Haines and P. Phu, Space Fence PDR Concept Development Phase, 2011 AMOS Conference Technical Papers.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilde, E.W.; Radway, J.C.; Santo Domingo, J.

    The major objective of this project was to examine the potential of a novel hydrophilic polyurethane foam as an immobilization medium for algal, bacteria, and other types of biomass, and to test the resulting foam/biomass aggregates for their use in cleaning up waters contaminated with heavy metals, radionuclides and toxic organic compounds. Initial investigations focused on the bioremoval of heavy metals from wastewaters at SRS using immobilized algal biomass. This effort met with limited success for reasons which included interference in the binding of biomass and target metals by various non-target constituents in the wastewater, lack of an appropriate wastewatermore » at SRS for testing, and the unavailability of bioreactor systems capable of optimizing contact of target pollutants with sufficient biomass binding sites. Subsequent studies comparing algal, bacterial, fungal, and higher plant biomass demonstrated that other biomass sources were also ineffective for metal bioremoval under the test conditions. Radionuclide bioremoval using a Tc-99 source provided more promising results than the metal removal studies with the various types of biomass, and indicated that the alga Cyanidium was the best of the tested sources of biomass for this application. However, all of the biomass/foam aggregates tested were substantially inferior to a TEVA resin for removing Tc-99 in comparative testing. The authors also explored the use of hydrophilic polyurethane foam to embed Burkholderia cepacia, which is an efficient degrader of trichloroethylene (TCE), a contaminant of considerable concern at SRS and elsewhere. The embedded population proved to be incapable of growth on nutrient media, but retained respiratory activity. Lastly, the degradative capabilities of embedded G4 were examined. Phenol- or benzene-induced bacteria retained the ability to degrade TCE and benzene. The authors were successful in inducing enzyme activity after the organisms had already been embedded.« less

  2. Flow and Heat Transfer Tests in New Loop at 2757 kPa (400 psi)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woloshun, Keith Albert

    2016-06-13

    A helium flow and heat transfer experiment has been designed for the new helium flow loop facility at LANL. This new facility is centered on an Aerzen GM 12.4 Root’s blower, selected for operation at higher pressure, up to 2757 kPa, and mass flow rate, up to 400 g/s. This replaces the previous Tuthill PD plus 3206 blower and loop limited to 2067 kPa (300 psi) and 100 g/s. The resistively heated test piece is comprised of 7 electric heaters with embedded thermocouples. The plant design for the Mo100 to Mo99 targets requires sharp bends and geometry changes in themore » helium flow tube immediately before and after the target. An idealized fully developed flow configuration with straight entry and exit will be tested and compared with an option that employs rectangular tubing to make the bend at a radius consistent with and practical for the actual plant design. The current plant design, with circular tubing and a sudden contraction to rectangular just prior to target entrance, will also be tested. This requires some modification of the test piece, as described in the report.« less

  3. [The establishment of a novel method of nano-immunomagnetic separation and Real-time PCR for detecting Vibrio cholerae from seafood].

    PubMed

    Cheng, Jinxia; Zeng, Jing; Liu, Li; Wei, Haiyan; Zhao, Xiaojuan; Zhang, Ximeng; Zhang, Lei; Zhang, Haiyu

    2014-02-01

    A novel method of Nano-Immunomagnetic Separation (Nano-IMS) plus Real-time PCR was established for detecting Vibrio cholerae. The Nano-Immunomagnetic Beads were created by using the monoclonal antibody of Vibrio cholerae, which was named Nano-IMB-Vc. Nano-IMB-Vc has specific adsorption of Vibrio cholerae, combined with Real-time PCR technology, a method for rapid detection of Vibrio cholerae was established. The capture specificity of Nano-IMB-Vc was tested by using 15 bacteria strains. The specificity of Real-time PCR method was tested by using 102 targets and 101 non-targets bacteria strains. The sensitivity of Nano-IMS plus Real-time PCR were tested in pure culture and in artificial samples and compared with NMKL No.156. The capture ratio of Nano-IMB-Vc was reached 70.2% at the level of 10(3) CFU/ml. In pure culture, the sensitivity of Nano-IMS plus Real-time PCR was reached at 5.4×10(2) CFU/ml. The specific of Real-time PCR method was tested by using 102 targets and 101 non-targets bacteria. The results showed that 102 strains of Vibrio cholerae test results were all positive, and the rest of the 101 strains of non-target bacteria test results were negative. No cross-reaction was founded. Add 1 CFU vibrio cholerae per 25 g sample, it could be detect with Nano-IMS plus Real-time PCR method after 8 hours enrichment. The Nano-IMS plus Real-time PCR method of Vibrio cholerae established in this study has good specificity and sensitivity, which could be applied to the rapid detection of Vibrio cholerae.

  4. What Does a Cue Do? Comparing Phonological and Semantic Cues for Picture Naming in Aphasia

    ERIC Educational Resources Information Center

    Meteyard, Lotte; Bose, Arpita

    2018-01-01

    Purpose: Impaired naming is one of the most common symptoms in aphasia, often treated with cued picture naming paradigms. It has been argued that semantic cues facilitate the reliable categorization of the picture, and phonological cues facilitate the retrieval of target phonology. To test these hypotheses, we compared the effectiveness of…

  5. Non-inferiority tests for anti-infective drugs using control group quantiles.

    PubMed

    Fay, Michael P; Follmann, Dean A

    2016-12-01

    In testing for non-inferiority of anti-infective drugs, the primary endpoint is often the difference in the proportion of failures between the test and control group at a landmark time. The landmark time is chosen to approximately correspond to the qth historic quantile of the control group, and the non-inferiority margin is selected to be reasonable for the target level q. For designing these studies, a troubling issue is that the landmark time must be pre-specified, but there is no guarantee that the proportion of control failures at the landmark time will be close to the target level q. If the landmark time is far from the target control quantile, then the pre-specified non-inferiority margin may not longer be reasonable. Exact variable margin tests have been developed by Röhmel and Kieser to address this problem, but these tests can have poor power if the observed control failure rate at the landmark time is far from its historic value. We develop a new variable margin non-inferiority test where we continue sampling until a pre-specified proportion of failures, q, have occurred in the control group, where q is the target quantile level. The test does not require any assumptions on the failure time distributions, and hence, no knowledge of the true [Formula: see text] control quantile for the study is needed. Our new test is exact and has power comparable to (or greater than) its competitors when the true control quantile from the study equals (or differs moderately from) its historic value. Our nivm R package performs the test and gives confidence intervals on the difference in failure rates at the true target control quantile. The tests can be applied to time to cure or other numeric variables as well. A substantial proportion of new anti-infective drugs being developed use non-inferiority tests in their development, and typically, a pre-specified landmark time and its associated difference margin are set at the design stage to match a specific target control quantile. If through changing standard of care or selection of a different population the target quantile for the control group changes from its historic value, then the appropriateness of the pre-specified margin at the landmark time may be questionable. Our proposed test avoids this problem by sampling until a pre-specified proportion of the controls have failed. © The Author(s) 2016.

  6. Predicting Ideological Prejudice

    PubMed Central

    Brandt, Mark J.

    2017-01-01

    A major shortcoming of current models of ideological prejudice is that although they can anticipate the direction of the association between participants’ ideology and their prejudice against a range of target groups, they cannot predict the size of this association. I developed and tested models that can make specific size predictions for this association. A quantitative model that used the perceived ideology of the target group as the primary predictor of the ideology-prejudice relationship was developed with a representative sample of Americans (N = 4,940) and tested against models using the perceived status of and choice to belong to the target group as predictors. In four studies (total N = 2,093), ideology-prejudice associations were estimated, and these observed estimates were compared with the models’ predictions. The model that was based only on perceived ideology was the most parsimonious with the smallest errors. PMID:28394693

  7. Ribozyme Mediated gRNA Generation for In Vitro and In Vivo CRISPR/Cas9 Mutagenesis.

    PubMed

    Lee, Raymond Teck Ho; Ng, Ashley Shu Mei; Ingham, Philip W

    2016-01-01

    CRISPR/Cas9 is now regularly used for targeted mutagenesis in a wide variety of systems. Here we report the use of ribozymes for the generation of gRNAs both in vitro and in zebrafish embryos. We show that incorporation of ribozymes increases the types of promoters and number of target sites available for mutagenesis without compromising mutagenesis efficiency. We have tested this by comparing the efficiency of mutagenesis of gRNA constructs with and without ribozymes and also generated a transgenic zebrafish expressing gRNA using a heat shock promoter (RNA polymerase II-dependent promoter) that was able to induce mutagenesis of its target. Our method provides a streamlined approach to test gRNA efficiency as well as increasing the versatility of conditional gene knock out in zebrafish.

  8. Combining targeted and nontargeted data analysis for liquid chromatography/high-resolution mass spectrometric analyses.

    PubMed

    Croley, Timothy R; White, Kevin D; Wong, Jon; Callahan, John H; Musser, Steven M; Antler, Margaret; Lashin, Vitaly; McGibbon, Graham A

    2013-03-01

    Increasing importation of food and the diversity of potential contaminants have necessitated more analytical testing of these foods. Historically, mass spectrometric methods for testing foods were confined to monitoring selected ions (SIM or MRM), achieving sensitivity by focusing on targeted ion signals. A limiting factor in this approach is that any contaminants not included on the target list are not typically identified and retrospective data mining is limited. A potential solution is to utilize high-resolution MS to acquire accurate mass full-scan data. Based on the instrumental resolution, these data can be correlated to the actual mass of a contaminant, which would allow for identification of both target compounds and compounds that are not on a target list (nontargets). The focus of this research was to develop software algorithms to provide rapid and accurate data processing of LC/MS data to identify both targeted and nontargeted analytes. Software from a commercial vendor was developed to process LC/MS data and the results were compared to an alternate, vendor-supplied solution. The commercial software performed well and demonstrated the potential for a fully automated processing solution. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Differences between conduction aphasia and Wernicke's aphasia.

    PubMed

    Anzaki, F; Izumi, S

    2001-07-01

    Conduction aphasia and Wernike's aphasia have been differentiated by the degree of auditory language comprehension. We quantitatively compared the speech sound errors of two conduction aphasia patients and three Wernicke's aphasia patients on various language modality tests. All of the patients were Japanese. The two conduction aphasia patients had "conduites d'approche" errors and phonological paraphasia. The patient with mild Wernicke's aphasia made various errors. In the patient with severe Wernicke's aphasia, neologism was observed. Phonological paraphasia in the two conduction aphasia patients seemed to occur when the examinee searched for the target word. They made more errors in vowels than in consonants of target words on the naming and repetition tests. They seemed to search the target word by the correct consonant phoneme and incorrect vocalic phoneme in the table of the Japanese alphabet. The Wernicke's aphasia patients who had severe impairment of auditory comprehension, made more errors in consonants than in vowels of target words. In conclusion, utterance of conduction aphasia and that of Wernicke's aphasia are qualitatively distinct.

  10. Perforation of thin aluminum alloy plates by blunt projectiles: An experimental and numerical investigation

    NASA Astrophysics Data System (ADS)

    Wei, G.; Zhang, W.

    2014-04-01

    Reducing the armor weight has become a research focus in terms of armored material. Due to high strength-to-density ratio, aluminum alloy has become a potential light armored material. In this study, both lab-scale ballistic test and finite element simulation were adopted to examine the ballistic resistance of aluminum alloy targets. Blunt high strength steel projectiles with 12.7 mm diameter were launched by light gas gun against 3.3 mm thickness 7A04 aluminum alloy plates at a velocity of 90~170 m/s. The ballistic limit velocity was obtained. Plugging failure and obvious structure deformation of targets were observed. Corresponding 2D finite element simulations were conducted by ABAQUS/EXPLICIT combined with material performance testing. The validity of numerical simulations was verified by comparing with the experimental results. Detailed analysis of the failure modes and characters of the targets were carried out to reveal the target damage mechanism combined with the numerical simulation.

  11. Transorbital therapy delivery: phantom testing

    NASA Astrophysics Data System (ADS)

    Ingram, Martha-Conley; Atuegwu, Nkiruka; Mawn, Louise; Galloway, Robert L.

    2011-03-01

    We have developed a combined image-guided and minimally invasive system for the delivery of therapy to the back of the eye. It is composed of a short 4.5 mm diameter endoscope with a magnetic tracker embedded in the tip. In previous work we have defined an optimized fiducial placement for accurate guidance to the back of the eye and are now moving to system testing. The fundamental difficulty in testing performance is establishing a target in a manner which closely mimics the physiological task. We have to have a penetrable material which obscures line of sight, similar to the orbital fat. In addition we need to have some independent measure of knowing when a target has been reached to compare to the ideal performance. Lastly, the target cannot be rigidly attached to the skull phantom since the optic nerve lies buried in the orbital fat. We have developed a skull phantom with white cloth stellate balls supporting a correctly sized globe. Placed in the white balls are red, blue, orange and yellow balls. One of the colored balls has been soaked in barium to make it bright on CT. The user guides the tracked endoscope to the target as defined by the images and tells us its color. We record task accuracy and time to target. We have tested this with 28 residents, fellows and attending physicians. Each physician performs the task twice guided and twice unguided. Results will be presented.

  12. [Passive ranging of infrared target using oxygen A-band and Elsasser model].

    PubMed

    Li, Jin-Hua; Wang, Zhao-Ba; Wang Zhi

    2014-09-01

    Passive ranging method of short range and single band was developed based on target radiation and attenuation characteristic of oxygen spectrum absorption. The relation between transmittance of oxygen A band and range of measured target was analyzed. Radiation strength distribution of measured target can be obtained according to the distribution law of absorption coefficient with environmental parameters. Passive ranging mathematical model of short ranges was established using Elsasser model with Lorentz line shape based on the computational methods of band average transmittance and high-temperature gas radiation narrowband model. The range of measured object was obtained using transmittance fitting with test data calculation and theoretical model. Besides, ranging precision was corrected considering the influence of oxygen absorption with enviromental parameter. The ranging experiment platform was established. The source was a 10 watt black body, and a grating spectrometer with 17 cm(-1) resolution was used. In order to improve the light receiving efficiency, light input was collected with 23 mm calibre telescope. The test data was processed for different range in 200 m. The results show that the transmittance accuracy was better than 2.18% in short range compared to the test data with predicted value in the same conditions.

  13. Three-dimensional particle simulation of back-sputtered carbon in electric propulsion test facility

    NASA Astrophysics Data System (ADS)

    Zheng, Hongru; Cai, Guobiao; Liu, Lihui; Shang, Shengfei; He, Bijiao

    2017-03-01

    The back-sputtering deposition on thruster surface caused by ion bombardment on chamber wall material affects the performance of thrusters during the ground based electric propulsion endurance tests. In order to decrease the back-sputtering deposition, most of vacuum chambers applied in electric propulsion experiments are equipped with anti-sputtering targets. In this paper, a three-dimensional model of plume experimental system (PES) including double layer anti-sputtering target is established. Simulation cases are made to simulate the plasma environment and sputtering effects when an ion thruster is working. The particle in cell (PIC) method and direct simulation Monte Carlo (DSMC) method is used to calculate the velocity and position of particles. Yamamura's model is used to simulate the sputtering process. The distribution of sputtered anti-sputtering target material is presented. The results show that the double layer anti-sputtering target can significantly reduce the deposition on thruster surface. The back-sputtering deposition rates on thruster exit surface for different cases are compared. The chevrons on the secondary target are rearranged to improve its performance. The position of secondary target has relation with the ion beam divergence angle, and the radius of the vacuum chamber. The back-sputtering deposition rate is lower when the secondary target covers the entire ion beam.

  14. Measurements of the effective atomic numbers of minerals using bremsstrahlung produced by low-energy electrons

    NASA Astrophysics Data System (ADS)

    Czarnecki, S.; Williams, S.

    2017-12-01

    The accuracy of a method for measuring the effective atomic numbers of minerals using bremsstrahlung intensities has been investigated. The method is independent of detector-efficiency and maximum accelerating voltage. In order to test the method, experiments were performed which involved low-energy electrons incident on thick malachite, pyrite, and galena targets. The resultant thick-target bremsstrahlung was compared to bremsstrahlung produced using a standard target, and experimental effective atomic numbers were calculated using data from a previous study (in which the Z-dependence of thick-target bremsstrahlung was studied). Comparisons of the results to theoretical values suggest that the method has potential for implementation in energy-dispersive X-ray spectroscopy systems.

  15. Radar for tracer particles

    NASA Astrophysics Data System (ADS)

    Ott, Felix; Herminghaus, Stephan; Huang, Kai

    2017-05-01

    We introduce a radar system capable of tracking a 5 mm spherical target continuously in three dimensions. The 10 GHz (X-band) radar system has a transmission power of 1 W and operates in the near field of the horn antennae. By comparing the phase shift of the electromagnetic wave traveling through the free space with an IQ-mixer, we obtain the relative movement of the target with respect to the antennae. From the azimuth and inclination angles of the receiving antennae obtained in the calibration, we reconstruct the target trajectory in a three-dimensional Cartesian system. Finally, we test the tracking algorithm with target moving in circular as well as in pendulum motions and discuss the capability of the radar system.

  16. The signature-based radiation-scanning approach to standoff detection of improvised explosive devices.

    PubMed

    Brewer, R L; Dunn, W L; Heider, S; Matthew, C; Yang, X

    2012-07-01

    The signature-based radiation-scanning technique for detection of improvised explosive devices is described. The technique seeks to detect nitrogen-rich chemical explosives present in a target. The technology compares a set of "signatures" obtained from a test target to a collection of "templates", sets of signatures for a target that contain an explosive in a specific configuration. Interrogation of nitrogen-rich fertilizer samples, which serve as surrogates for explosives, is shown experimentally to be able to discriminate samples of 3.8L and larger. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Should cell-free DNA testing be used to target antenatal rhesus immune globulin administration?

    PubMed

    Ma, Kimberly K; Rodriguez, Maria I; Cheng, Yvonne W; Norton, Mary E; Caughey, Aaron B

    2016-01-01

    To compare the rates of alloimmunization with the use of cell-free DNA (cfDNA) screening to target antenatal rhesus immune globulin (RhIG) prenatally, versus routine administration of RhIG in rhesus D (RhD)-negative pregnant women in a theoretic cohort using a decision-analytic model. A decision-analytic model compared cfDNA testing to routine antenatal RhIG administration. The primary outcome was maternal sensitization to RhD antigen. Sensitivity and specificity of cfDNA testing were assumed to be 99.8% and 95.3%, respectively. Univariate and bivariate sensitivity analyses, Monte Carlo simulation, and threshold analyses were performed. In a cohort of 10,000 RhD-negative women, 22.6 sensitizations would occur with utilization of cfDNA, while 20 sensitizations would occur with routine RhIG. Only when the sensitivity of the cfDNA test reached 100%, the rate of sensitization was equal for both cfDNA and RhIG. Otherwise, routine RhIG minimized the rate of sensitization, especially given RhIG is readily available in the United States. Adoption of cfDNA testing would result in a 13.0% increase in sensitization among RhD-negative women in a theoretical cohort taking into account the ethnic diversity of the United States' population.

  18. Contextual remapping in visual search after predictable target-location changes.

    PubMed

    Conci, Markus; Sun, Luning; Müller, Hermann J

    2011-07-01

    Invariant spatial context can facilitate visual search. For instance, detection of a target is faster if it is presented within a repeatedly encountered, as compared to a novel, layout of nontargets, demonstrating a role of contextual learning for attentional guidance ('contextual cueing'). Here, we investigated how context-based learning adapts to target location (and identity) changes. Three experiments were performed in which, in an initial learning phase, observers learned to associate a given context with a given target location. A subsequent test phase then introduced identity and/or location changes to the target. The results showed that contextual cueing could not compensate for target changes that were not 'predictable' (i.e. learnable). However, for predictable changes, contextual cueing remained effective even immediately after the change. These findings demonstrate that contextual cueing is adaptive to predictable target location changes. Under these conditions, learned contextual associations can be effectively 'remapped' to accommodate new task requirements.

  19. Current target acquisition methodology in force on force simulations

    NASA Astrophysics Data System (ADS)

    Hixson, Jonathan G.; Miller, Brian; Mazz, John P.

    2017-05-01

    The U.S. Army RDECOM CERDEC NVESD MSD's target acquisition models have been used for many years by the military community in force on force simulations for training, testing, and analysis. There have been significant improvements to these models over the past few years. The significant improvements are the transition of ACQUIRE TTP-TAS (ACQUIRE Targeting Task Performance Target Angular Size) methodology for all imaging sensors and the development of new discrimination criteria for urban environments and humans. This paper is intended to provide an overview of the current target acquisition modeling approach and provide data for the new discrimination tasks. This paper will discuss advances and changes to the models and methodologies used to: (1) design and compare sensors' performance, (2) predict expected target acquisition performance in the field, (3) predict target acquisition performance for combat simulations, and (4) how to conduct model data validation for combat simulations.

  20. A randomized controlled trial of a multicomponent, targeted, low-literacy educational intervention compared with a nontargeted intervention to boost colorectal cancer screening with fecal immunochemical testing in community clinics.

    PubMed

    Davis, Stacy N; Christy, Shannon M; Chavarria, Enmanuel A; Abdulla, Rania; Sutton, Steven K; Schmidt, Alyssa R; Vadaparampil, Susan T; Quinn, Gwendolyn P; Simmons, Vani N; Ufondu, Chukwudi B; Ravindra, Chitra; Schultz, Ida; Roetzheim, Richard G; Shibata, David; Meade, Cathy D; Gwede, Clement K

    2017-04-15

    The objective of the current study was to improve colorectal cancer (CRC) screening uptake with the fecal immunochemical test (FIT). The current study investigated the differential impact of a multicomponent, targeted, low-literacy educational intervention compared with a standard, nontargeted educational intervention. Patients aged 50 to 75 years who were of average CRC risk and not up-to-date with CRC screening were recruited from either a federally qualified health center or a primary care community health clinic. Patients were randomized to the intervention condition (targeted photonovella booklet/DVD plus FIT kit) or comparison condition (standard Centers for Disease Control and Prevention brochure plus FIT kit). The main outcome was screening with FIT within 180 days of delivery of the intervention. Of the 416 participants, 54% were female; the participants were racially and ethnically diverse (66% white, 10% Hispanic, and 28% African American), predominantly of low income, and insured (the majority had county health insurance). Overall, the FIT completion rate was 81%, with 78.1% of participants in the intervention versus 83.5% of those in the comparison condition completing FIT (P =  .17). In multivariate analysis, having health insurance was found to be the primary factor predicting a lack of FIT screening (adjusted odds ratio, 2.10; 95% confidence interval, 1.04-4.26 [P =  .04]). The multicomponent, targeted, low-literacy materials were not found to be significantly different or more effective in increasing FIT uptake compared with the nontargeted materials. Provision of a FIT test plus education may provide a key impetus to improve the completion of CRC screening. The type of educational material (targeted vs nontargeted) may matter less. The findings of the current study provide a unique opportunity for clinics to adopt FIT and to choose the type of patient education materials based on clinic, provider, and patient preferences. Cancer 2017;123:1390-1400. © 2016 American Cancer Society. © 2016 American Cancer Society.

  1. Inhibition of hexokinase-2 with targeted liposomal 3-bromopyruvate in an ovarian tumor spheroid model of aerobic glycolysis

    PubMed Central

    Gandham, Srujan Kumar; Talekar, Meghna; Singh, Amit; Amiji, Mansoor M

    2015-01-01

    Background The objective of this study was to evaluate the expression levels of glycolytic markers, especially hexokinase-2 (HK2), using a three-dimensional multicellular spheroid model of human ovarian adenocarcinoma (SKOV-3) cells and to develop an epidermal growth factor receptor-targeted liposomal formulation for improving inhibition of HK2 and the cytotoxicity of 3-bromopyruvate (3-BPA). Methods Multicellular SKOV-3 tumor spheroids were developed using the hanging drop method and expression levels of glycolytic markers were examined. Non-targeted and epidermal growth factor receptor-targeted liposomal formulations of 3-BPA were formulated and characterized. Permeability and cellular uptake of the liposomal formulations in three-dimensional SKOV-3 spheroids was evaluated using confocal microscopy. The cytotoxicity and HK2 inhibition potential of solution form of 3-BPA was compared to the corresponding liposomal formulation by using cell proliferation and HK2 enzymatic assays. Results SKOV-3 spheroids were reproducibly developed using the 96-well hanging drop method, with an average size of 900 µm by day 5. HK2 enzyme activity levels under hypoxic conditions were found to be higher than under normoxic conditions (P<0.0001, Student’s t-test, unpaired and two-tailed). Liposomal formulations (both non-targeted and targeted) of 3-BPA showed a more potent inhibitory effect (P<0.001, Student’s t-test, unpaired and two-tailed) at a dose of 50 µM than the aqueous solution form at 3, 6, and 24 hours post administration. Similarly, the cytotoxic activity 3-BPA at various concentrations (10 µM–100 µM) showed that the liposomal formulations had an enhanced cytotoxic effect of 2–5-fold (P<0.0001, Student’s t-test, unpaired and two-tailed) when compared to the aqueous solution form for both 10 µM and 25 µM concentrations. Conclusion SKOV-3 spheroids developed by the hanging drop method can be used as a tumor aerobic glycolysis model for evaluation of therapies targeting the glycolytic pathway in cancer cells. Encapsulation of 3-BPA in a liposomal formulation improved permeability, HK2 inhibition, and cytotoxicity in the multicellular spheroid model. PMID:26185443

  2. Inhibition of hexokinase-2 with targeted liposomal 3-bromopyruvate in an ovarian tumor spheroid model of aerobic glycolysis.

    PubMed

    Gandham, Srujan Kumar; Talekar, Meghna; Singh, Amit; Amiji, Mansoor M

    2015-01-01

    The objective of this study was to evaluate the expression levels of glycolytic markers, especially hexokinase-2 (HK2), using a three-dimensional multicellular spheroid model of human ovarian adenocarcinoma (SKOV-3) cells and to develop an epidermal growth factor receptor-targeted liposomal formulation for improving inhibition of HK2 and the cytotoxicity of 3-bromopyruvate (3-BPA). Multicellular SKOV-3 tumor spheroids were developed using the hanging drop method and expression levels of glycolytic markers were examined. Non-targeted and epidermal growth factor receptor-targeted liposomal formulations of 3-BPA were formulated and characterized. Permeability and cellular uptake of the liposomal formulations in three-dimensional SKOV-3 spheroids was evaluated using confocal microscopy. The cytotoxicity and HK2 inhibition potential of solution form of 3-BPA was compared to the corresponding liposomal formulation by using cell proliferation and HK2 enzymatic assays. SKOV-3 spheroids were reproducibly developed using the 96-well hanging drop method, with an average size of 900 µm by day 5. HK2 enzyme activity levels under hypoxic conditions were found to be higher than under normoxic conditions (P<0.0001, Student's t-test, unpaired and two-tailed). Liposomal formulations (both non-targeted and targeted) of 3-BPA showed a more potent inhibitory effect (P<0.001, Student's t-test, unpaired and two-tailed) at a dose of 50 µM than the aqueous solution form at 3, 6, and 24 hours post administration. Similarly, the cytotoxic activity 3-BPA at various concentrations (10 µM-100 µM) showed that the liposomal formulations had an enhanced cytotoxic effect of 2-5-fold (P<0.0001, Student's t-test, unpaired and two-tailed) when compared to the aqueous solution form for both 10 µM and 25 µM concentrations. SKOV-3 spheroids developed by the hanging drop method can be used as a tumor aerobic glycolysis model for evaluation of therapies targeting the glycolytic pathway in cancer cells. Encapsulation of 3-BPA in a liposomal formulation improved permeability, HK2 inhibition, and cytotoxicity in the multicellular spheroid model.

  3. It only takes once: The absent-exempt heuristic and reactions to comparison-based sexual risk information

    PubMed Central

    Stock, Michelle L.; Gibbons, Frederick X.; Beekman, Janine B.; Gerrard, Meg

    2015-01-01

    Three studies (N = 545) investigated the effects of social comparison on a type of heuristic called “absent-exempt” (AE; feeling exempt from future risk). Study 1 examined how comparison with an infected peer (comparison target) who was similar or non-similar in terms of sexual risk (number of partners, lack of condom use), influenced willingness and intentions to engage in sex without a condom and conditional perceived vulnerability to a sexually transmitted disease (STD). Participants generally reported lower willingness and higher conditional vulnerability if they compared with a similar-risk level target. However, high-risk students who compared with a low-risk comparison target engaged in what appeared to be AE thinking, reporting the highest willingness and lowest conditional vulnerability. Intentions to have sex without a condom were not influenced. Study 2 included a direct measure of AE thinking, and compared the impact of a low-risk comparison target with a Public Service Announcement (PSA) stating that negative outcomes (e.g., STDs) can happen even to low-risk targets. Among high-risk participants, comparing with the low-risk target led to an increase in AE thinking. As expected, the effects in Studies 1 and 2 were strongest among participants high in tendencies to socially compare. Study 3 explored whether AE thinking could be decreased by encouraging more reasoned processing. Results indicated that asking participants to think about the illogicality of AE thinking reduces AE endorsement and increases STD testing intentions. Findings suggest that comparison-based information can have a stronger influence on health cognitions than analytic-based information (e.g., most PSAs). Implications for dual-processing models of decision-making and their applicability to interventions and health messages are discussed. PMID:26098587

  4. It only takes once: The absent-exempt heuristic and reactions to comparison-based sexual risk information.

    PubMed

    Stock, Michelle L; Gibbons, Frederick X; Beekman, Janine B; Gerrard, Meg

    2015-07-01

    Three studies (N = 545) investigated the effects of social comparison on the "absent-exempt" (AE) heuristic (feeling exempt from future risk). Study 1 examined how comparison with an infected peer (comparison target) who was similar or nonsimilar in terms of sexual risk (number of partners, lack of condom use), influenced willingness and intentions to engage in sex without a condom, and conditional perceived vulnerability to an STD. Participants generally reported lower willingness and higher conditional vulnerability if they compared with a similar-risk level target. However, high-risk students who compared with a low-risk target engaged in what appeared to be AE thinking, reporting the highest willingness and lowest conditional vulnerability. Intentions to have sex without a condom were not influenced. Study 2 included a direct measure of AE thinking and compared the impact of a low-risk comparison target with a Public Service Announcement (PSA) stating that negative outcomes (STDs) can happen even to low-risk targets. Among high-risk participants, comparing with the low-risk target increased AE thinking. The effects in Studies 1 and 2 were strongest among participants high in tendencies to socially compare. Study 3 explored whether AE thinking could be decreased by encouraging more reasoned processing. Results indicated that asking participants to think about the illogicality of AE thinking reduces AE endorsement and increases STD testing intentions. Findings suggest that comparison-based information can have a stronger influence on health cognitions than analytic-based information (e.g., most PSAs). Implications for dual-processing models of decision-making and their applicability to health messages are discussed. (c) 2015 APA, all rights reserved).

  5. Multiplex Identification of Gram-Positive Bacteria and Resistance Determinants Directly from Positive Blood Culture Broths: Evaluation of an Automated Microarray-Based Nucleic Acid Test

    PubMed Central

    Buchan, Blake W.; Ginocchio, Christine C.; Manii, Ryhana; Cavagnolo, Robert; Pancholi, Preeti; Swyers, Lettie; Thomson, Richard B.; Anderson, Christopher; Kaul, Karen; Ledeboer, Nathan A.

    2013-01-01

    Background A multicenter study was conducted to evaluate the diagnostic accuracy (sensitivity and specificity) of the Verigene Gram-Positive Blood Culture Test (BC-GP) test to identify 12 Gram-positive bacterial gene targets and three genetic resistance determinants directly from positive blood culture broths containing Gram-positive bacteria. Methods and Findings 1,252 blood cultures containing Gram-positive bacteria were prospectively collected and tested at five clinical centers between April, 2011 and January, 2012. An additional 387 contrived blood cultures containing uncommon targets (e.g., Listeria spp., S. lugdunensis, vanB-positive Enterococci) were included to fully evaluate the performance of the BC-GP test. Sensitivity and specificity for the 12 specific genus or species targets identified by the BC-GP test ranged from 92.6%–100% and 95.4%–100%, respectively. Identification of the mecA gene in 599 cultures containing S. aureus or S. epidermidis was 98.6% sensitive and 94.3% specific compared to cefoxitin disk method. Identification of the vanA gene in 81 cultures containing Enterococcus faecium or E. faecalis was 100% sensitive and specific. Approximately 7.5% (87/1,157) of single-organism cultures contained Gram-positive bacteria not present on the BC-GP test panel. In 95 cultures containing multiple organisms the BC-GP test was in 71.6% (68/95) agreement with culture results. Retrospective analysis of 107 separate blood cultures demonstrated that identification of methicillin resistant S. aureus and vancomycin resistant Enterococcus spp. was completed an average of 41.8 to 42.4 h earlier using the BC-GP test compared to routine culture methods. The BC-GP test was unable to assign mecA to a specific organism in cultures containing more than one Staphylococcus isolate and does not identify common blood culture contaminants such as Micrococcus, Corynebacterium, and Bacillus. Conclusions The BC-GP test is a multiplex test capable of detecting most leading causes of Gram-positive bacterial blood stream infections as well as genetic markers of methicillin and vancomycin resistance directly from positive blood cultures. Please see later in the article for the Editors' Summary PMID:23843749

  6. The acquisition of contextual cueing effects by persons with and without intellectual disability.

    PubMed

    Merrill, Edward C; Conners, Frances A; Yang, Yingying; Weathington, Dana

    2014-10-01

    Two experiments were conducted to compare the acquisition of contextual cueing effects of adolescents and young adults with intellectual disabilities (ID) relative to typically developing children and young adults. Contextual cueing reflects an implicit, memory based attention guidance mechanism that results in faster search for target locations that have been previously experienced in a predictable context. In the study, participants located a target stimulus embedded in a context of numerous distracter stimuli. During a learning phase, the location of the target was predictable from the location of the distracters in the search displays. We then compared response times to locating predictable relative to unpredictable targets presented in a test phase. In Experiment 1, all of the distracters predicted the location of the target. In Experiment 2, half of the distracters predicted the location of the target while the other half varied randomly. The participants with ID exhibited significant contextual facilitation in both experiments, with the magnitude of facilitation being similar to that of the typically developing (TD) children and adults. We concluded that deficiencies in contextual cueing are not necessarily associated with low measured intelligence that results in a classification of ID. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Use of a vision model to quantify the significance of factors effecting target conspicuity

    NASA Astrophysics Data System (ADS)

    Gilmore, M. A.; Jones, C. K.; Haynes, A. W.; Tolhurst, D. J.; To, M.; Troscianko, T.; Lovell, P. G.; Parraga, C. A.; Pickavance, K.

    2006-05-01

    When designing camouflage it is important to understand how the human visual system processes the information to discriminate the target from the background scene. A vision model has been developed to compare two images and detect differences in local contrast in each spatial frequency channel. Observer experiments are being undertaken to validate this vision model so that the model can be used to quantify the relative significance of different factors affecting target conspicuity. Synthetic imagery can be used to design improved camouflage systems. The vision model is being used to compare different synthetic images to understand what features in the image are important to reproduce accurately and to identify the optimum way to render synthetic imagery for camouflage effectiveness assessment. This paper will describe the vision model and summarise the results obtained from the initial validation tests. The paper will also show how the model is being used to compare different synthetic images and discuss future work plans.

  8. An Exploratory Study Investigating the Effects of Barefoot Running on Working Memory.

    PubMed

    Alloway, Ross G; Alloway, Tracy Packiam; Magyari, Peter M; Floyd, Shelley

    2016-04-01

    The aim of the present study was to compare the potential cognitive benefits of running barefoot compared to shod. Young adults (N = 72, M age = 24.4 years, SD = 5.5) ran both barefoot and shod on a running track while stepping on targets (poker chips) and when not stepping on targets. The main finding was that participants performed better on a working memory test when running barefoot compared to shod, but only when they had to step on targets. These results supported the idea that additional attention is needed when running barefoot to avoid stepping on objects that could potentially injure the foot. Significant increases in participant's heart rate were also found in the barefoot condition. No significant differences were found in participants' speed across conditions. These findings suggested that working memory may be enhanced after at least 16 minutes of barefoot running if the individual has to focus attention on the ground. © The Author(s) 2016.

  9. Iterative Design and Testing for the Development of a Game-Based Chlamydia Awareness Intervention: A Pilot Study.

    PubMed

    Jiang, Rui; McKanna, James; Calabrese, Samantha; Seif El-Nasr, Magy

    2017-08-01

    Herein we describe a methodology for developing a game-based intervention to raise awareness of Chlamydia and other sexually transmitted infections among youth in Boston's underserved communities. We engaged in three design-based experiments. These utilized mixed methods, including playtesting and assessment methods, to examine the overall effectiveness of the game. In this case, effectiveness is defined as (1) engaging the target group, (2) increasing knowledge about Chlamydia, and (3) changing attitudes toward Chlamydia testing. These three experiments were performed using participants from different communities and with slightly different versions of the game, as we iterated through the design/feedback process. Overall, participants who played the game showed a significant increase in participants' knowledge of Chlamydia compared with those in the control group (P = 0.0002). The version of the game, including elements specifically targeting systemic thinking, showed significant improvement in participants' intent to get tested compared with the version of the game without such elements (Stage 2: P > 0.05; Stage 3: P = 0.0045). Furthermore, during both Stage 2 and Stage 3, participants showed high levels of enjoyment, mood, and participation and moderate levels of game engagement and social engagement. During Stage 3, however, participants' game engagement (P = 0.0003), social engagement (P = 0.0003), and participation (P = 0.0003) were significantly higher compared with those of Stage 2. Thus, we believe that motivation improvements from Stage 2 to 3 were also effective. Finally, participants' overall learning effectiveness was correlated with their prepositive affect (r = 0.52) and their postproblem hierarchy (r = -0.54). The game improved considerably from its initial conception through three stages of iterative design and feedback. Our assessment methods for each stage targeted and integrated learning, health, and engagement outcomes. Lessons learned through this iterative design process are a great contribution to the games for health community, especially in targeting the development of health and learning goals through game design.

  10. Rater Comparability Scoring and Equating: Does Choice of Target Population Weights Matter in This Context?

    ERIC Educational Resources Information Center

    Puhan, Gautam

    2013-01-01

    When a constructed-response test form is reused, raw scores from the two administrations of the form may not be comparable. The solution to this problem requires a rescoring, at the current administration, of examinee responses from the previous administration. The scores from this "rescoring" can be used as an anchor for equating. In…

  11. The Effects of Two Scheduling Formats on Student Achievement in a Suburban High School Setting

    ERIC Educational Resources Information Center

    Jackson, Kenyada Morton

    2013-01-01

    Limited studies have been conducted on the relationship between scheduling formats and academic performance of high school students. At the target high school, students underperform on standardized tests in English language arts (ELA) and math. The purpose of this causal comparative quantitative study was to compare the means of ELA and math test…

  12. Comparative genome analysis identifies novel nucleic acid diagnostic targets for use in the specific detection of Haemophilus influenzae.

    PubMed

    Coughlan, Helena; Reddington, Kate; Tuite, Nina; Boo, Teck Wee; Cormican, Martin; Barrett, Louise; Smith, Terry J; Clancy, Eoin; Barry, Thomas

    2015-10-01

    Haemophilus influenzae is recognised as an important human pathogen associated with invasive infections, including bloodstream infection and meningitis. Currently used molecular-based diagnostic assays lack specificity in correctly detecting and identifying H. influenzae. As such, there is a need to develop novel diagnostic assays for the specific identification of H. influenzae. Whole genome comparative analysis was performed to identify putative diagnostic targets, which are unique in nucleotide sequence to H. influenzae. From this analysis, we identified 2H. influenzae putative diagnostic targets, phoB and pstA, for use in real-time PCR diagnostic assays. Real-time PCR diagnostic assays using these targets were designed and optimised to specifically detect and identify all 55H. influenzae strains tested. These novel rapid assays can be applied to the specific detection and identification of H. influenzae for use in epidemiological studies and could also enable improved monitoring of invasive disease caused by these bacteria. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. The enduring effects of psychodynamic treatments vis-a-vis alternative treatments: A multilevel longitudinal meta-analysis

    NASA Astrophysics Data System (ADS)

    Kivlighan, D. Martin, III

    Although evidence suggests that the benefits of psychodynamic treatments are sustained over time, presently it is unclear whether these sustained benefits are superior to non-psychodynamic treatments. Additionally, the extant literature comparing the sustained benefits of psychodynamic treatments compared to alternative treatments is limited with methodological shortcomings. The purpose of the current study was to conduct a rigorous test of the growth of the benefits of psychodynamic treatments relative to alternative treatments across distinct domains of change (i.e., all outcome measures, targeted outcome measures, non-targeted outcome measures, and personality outcome measures). To do so, the study employed strict inclusion criteria to identify randomized clinical trials that directly compared at least one bona fide psychodynamic treatment and one bona fide non-psychodynamic treatment. Hierarchical linear modeling (Raudenbush, Bryk, Cheong & Congdon, du Toit, 2011) was used to longitudinally model the impact of psychodynamic treatments compared to non-psychodynamic treatments at post-treatment and to compare the growth (i.e., slope) of effects beyond treatment completion. Findings from the present meta-analysis indicated that psychodynamic treatments and non-psychodynamic treatments were equally efficacious at post-treatment and at follow-up for combined outcomes ( k = 20), targeted outcomes (k =19), non-targeted outcomes (k =17), and personality outcomes (k =6). Clinical implications, directions for future research, and limitations are discussed.

  14. A comparison between computer-controlled and set work rate exercise based on target heart rate

    NASA Technical Reports Server (NTRS)

    Pratt, Wanda M.; Siconolfi, Steven F.; Webster, Laurie; Hayes, Judith C.; Mazzocca, Augustus D.; Harris, Bernard A., Jr.

    1991-01-01

    Two methods are compared for observing the heart rate (HR), metabolic equivalents, and time in target HR zone (defined as the target HR + or - 5 bpm) during 20 min of exercise at a prescribed intensity of the maximum working capacity. In one method, called set-work rate exercise, the information from a graded exercise test is used to select a target HR and to calculate a corresponding constant work rate that should induce the desired HR. In the other method, the work rate is controlled by a computer algorithm to achieve and maintain a prescribed target HR. It is shown that computer-controlled exercise is an effective alternative to the traditional set work rate exercise, particularly when tight control of cardiovascular responses is necessary.

  15. Multi-voxel pattern analysis reveals increased memory targeting and reduced use of retrieved details during single-agenda source monitoring

    PubMed Central

    McDuff, Susan G. R.; Frankel, Hillary C.; Norman, Kenneth A.

    2009-01-01

    We used multi-voxel pattern analysis (MVPA) of fMRI data to gain insight into how subjects’ retrieval agendas influence source memory judgments (was item X studied using source Y?). In Experiment 1, we used a single-agenda test where subjects judged whether items were studied with the targeted source or not. In Experiment 2, we used a multi-agenda test where subjects judged whether items were studied using the targeted source, studied using a different source, or nonstudied. To evaluate the differences between single- and multi-agenda source monitoring, we trained a classifier to detect source-specific fMRI activity at study, and then we applied the classifier to data from the test phase. We focused on trials where the targeted source and the actual source differed, so we could use MVPA to track neural activity associated with both the targeted source and the actual source. Our results indicate that single-agenda monitoring was associated with increased focus on the targeted source (as evidenced by increased targeted-source activity, relative to baseline) and reduced use of information relating to the actual, non-target source. In the multi-agenda experiment, high-levels of actual-source activity were associated with increased correct rejections, suggesting that subjects were using recollection of actual-source information to avoid source memory errors. In the single-agenda experiment, there were comparable levels of actual-source activity (suggesting that recollection was taking place), but the relationship between actual-source activity and behavior was absent (suggesting that subjects were failing to make proper use of this information). PMID:19144851

  16. Nanostructured Lipid Carriers as Multifunctional Nanomedicine Platform for Pulmonary Co-Delivery of Anticancer Drugs and siRNA

    PubMed Central

    Taratula, Oleh; Kuzmov, Andriy; Shah, Milin; Garbuzenko, Olga B.; Minko, Tamara

    2013-01-01

    We developed, synthesized, and tested a multifunctional nanostructured lipid nanocarrier-based system (NLCS) for efficient delivery of an anticancer drug and siRNA directly into the lungs by inhalation. The system contains: (1) nanostructured lipid carriers (NLC); (2) anticancer drug (doxorubicin or paclitaxel); (3) siRNA targeted to MRP1 mRNA as a suppressor of pump drug resistance; (4) siRNA targeted to BCL2 mRNA as a suppressor of nonpump cellular resistance and (5) a modified synthetic analog of luteinizing hormone-releasing hormone (LHRH) as a targeting moiety specific to the receptors that are overexpressed in the plasma membrane of lung cancer cells. The NLCS was tested in vitro using human lung cancer cells and in vivo utilizing mouse orthotopic model of human lung cancer. After inhalation, the proposed NLCS effectively delivered its payload into lung cancer cells leaving healthy lung tissues intact and also significantly decreasing the exposure of healthy organs when compared with intravenous injection. The NLCS showed enhanced antitumor activity when compared with intravenous treatment. The data obtained demonstrated high efficiency of proposed NLCS for tumor-targeted local delivery by inhalation of anticancer drugs and mixture of siRNAs specifically to lung cancer cells and, as a result, efficient suppression of tumor growth and prevention of adverse side effects on healthy organs. PMID:23648833

  17. Active eye fixation performance in 940 young men: effects of IQ, schizotypy, anxiety and depression.

    PubMed

    Smyrnis, N; Kattoulas, E; Evdokimidis, I; Stefanis, N C; Avramopoulos, D; Pantes, G; Theleritis, C; Stefanis, C N

    2004-05-01

    A total of 940 young men performed a task in which they actively maintained fixation for 50 s in three conditions: a). on a visual target, b). on a visual target while distracting targets appeared briefly on the periphery and c). with no visual target present. The same individuals completed psychometric evaluation tests measuring IQ, schizotypy and current state-dependent psychopathology. The proportion of fixation time decreased and saccade frequency increased in condition b compared wih condition a, and sequentially in condition c compared with condition b. A trend towards a decrease in proportion of fixation time and increase in saccade frequency was found as the subjects maintained fixation during the task and this time-dependent deterioration of performance was again most pronounced in condition c, less so in condition b and absent in condition a. Psychometric test scores were significantly correlated with fixation performance in the population. Worse performance in all three fixation conditions was observed for individuals with lower IQ scores. A deterioration of fixation performance with time in condition b was correlated with disorganization characteristics of schizotypy, suggesting that these individuals had difficulty maintaining active fixation in the presence of increased inhibitory load. A connection of such a difficulty with the frontal lobes and their role in the control of voluntary inhibitory functions is discussed.

  18. A statistical simulation model for field testing of non-target organisms in environmental risk assessment of genetically modified plants.

    PubMed

    Goedhart, Paul W; van der Voet, Hilko; Baldacchino, Ferdinando; Arpaia, Salvatore

    2014-04-01

    Genetic modification of plants may result in unintended effects causing potentially adverse effects on the environment. A comparative safety assessment is therefore required by authorities, such as the European Food Safety Authority, in which the genetically modified plant is compared with its conventional counterpart. Part of the environmental risk assessment is a comparative field experiment in which the effect on non-target organisms is compared. Statistical analysis of such trials come in two flavors: difference testing and equivalence testing. It is important to know the statistical properties of these, for example, the power to detect environmental change of a given magnitude, before the start of an experiment. Such prospective power analysis can best be studied by means of a statistical simulation model. This paper describes a general framework for simulating data typically encountered in environmental risk assessment of genetically modified plants. The simulation model, available as Supplementary Material, can be used to generate count data having different statistical distributions possibly with excess-zeros. In addition the model employs completely randomized or randomized block experiments, can be used to simulate single or multiple trials across environments, enables genotype by environment interaction by adding random variety effects, and finally includes repeated measures in time following a constant, linear or quadratic pattern in time possibly with some form of autocorrelation. The model also allows to add a set of reference varieties to the GM plants and its comparator to assess the natural variation which can then be used to set limits of concern for equivalence testing. The different count distributions are described in some detail and some examples of how to use the simulation model to study various aspects, including a prospective power analysis, are provided.

  19. A statistical simulation model for field testing of non-target organisms in environmental risk assessment of genetically modified plants

    PubMed Central

    Goedhart, Paul W; van der Voet, Hilko; Baldacchino, Ferdinando; Arpaia, Salvatore

    2014-01-01

    Genetic modification of plants may result in unintended effects causing potentially adverse effects on the environment. A comparative safety assessment is therefore required by authorities, such as the European Food Safety Authority, in which the genetically modified plant is compared with its conventional counterpart. Part of the environmental risk assessment is a comparative field experiment in which the effect on non-target organisms is compared. Statistical analysis of such trials come in two flavors: difference testing and equivalence testing. It is important to know the statistical properties of these, for example, the power to detect environmental change of a given magnitude, before the start of an experiment. Such prospective power analysis can best be studied by means of a statistical simulation model. This paper describes a general framework for simulating data typically encountered in environmental risk assessment of genetically modified plants. The simulation model, available as Supplementary Material, can be used to generate count data having different statistical distributions possibly with excess-zeros. In addition the model employs completely randomized or randomized block experiments, can be used to simulate single or multiple trials across environments, enables genotype by environment interaction by adding random variety effects, and finally includes repeated measures in time following a constant, linear or quadratic pattern in time possibly with some form of autocorrelation. The model also allows to add a set of reference varieties to the GM plants and its comparator to assess the natural variation which can then be used to set limits of concern for equivalence testing. The different count distributions are described in some detail and some examples of how to use the simulation model to study various aspects, including a prospective power analysis, are provided. PMID:24834325

  20. C–IBI: Targeting cumulative coordination within an iterative protocol to derive coarse-grained models of (multi-component) complex fluids

    DOE PAGES

    de Oliveira, Tiago E.; Netz, Paulo A.; Kremer, Kurt; ...

    2016-05-03

    We present a coarse-graining strategy that we test for aqueous mixtures. The method uses pair-wise cumulative coordination as a target function within an iterative Boltzmann inversion (IBI) like protocol. We name this method coordination iterative Boltzmann inversion (C–IBI). While the underlying coarse-grained model is still structure based and, thus, preserves pair-wise solution structure, our method also reproduces solvation thermodynamics of binary and/or ternary mixtures. In addition, we observe much faster convergence within C–IBI compared to IBI. To validate the robustness, we apply C–IBI to study test cases of solvation thermodynamics of aqueous urea and a triglycine solvation in aqueous urea.

  1. Characterization of a parallel beam CCD optical-CT apparatus for 3D radiation dosimetry

    NASA Astrophysics Data System (ADS)

    Krstajić, Nikola; Doran, Simon J.

    2006-12-01

    This paper describes the initial steps we have taken in establishing CCD based optical-CT as a viable alternative for 3-D radiation dosimetry. First, we compare the optical density (OD) measurements from a high quality test target and variable neutral density filter (VNDF). A modulation transfer function (MTF) of individual projections is derived for three positions of the sinusoidal test target within the scanning tank. Our CCD is then characterized in terms of its signal-to-noise ratio (SNR). Finally, a sample reconstruction of a scan of a PRESAGETM (registered trademark of Heuris Pharma, NJ, Skillman, USA.) dosimeter is given, demonstrating the capabilities of the apparatus.

  2. A Tissue-Mimicking Ultrasound Test Object Using Droplet Vaporization to Create Point Targets

    PubMed Central

    Carneal, Catherine M.; Kripfgans, Oliver D.; Krücker, Jochen; Carson, Paul L.; Fowlkes, J. Brian

    2012-01-01

    Ultrasound test objects containing reference point targets could be useful for evaluating ultrasound systems and phase aberration correction methods. Polyacrylamide gels containing albumin-stabilized droplets (3.6 µm mean diameter) of dodecafluoropentane (DDFP) are being developed for this purpose. Perturbation by ultrasound causes spontaneous vaporization of the superheated droplets to form gas bubbles, a process termed acoustic droplet vaporization (ADV). The resulting bubbles (20 to 160 µm diameter) are small compared with acoustic wavelengths in diagnostic ultrasound and are theoretically suitable for use as point targets (phase errors <20° for typical f-numbers). Bubbles distributed throughout the material are convenient for determining the point spread function in an imaging plane or volume. Cooling the gel causes condensation of the DDFP droplets, which may be useful for storage. Studying ADV in such viscoelastic media could provide insight into potential bioeffects from rapid bubble formation. PMID:21937339

  3. Selective Inhibition of Histone Deacetylation in Melanoma Increases Targeted Gene Delivery by a Bacteriophage Viral Vector.

    PubMed

    Campbell, Samuel; Suwan, Keittisak; Waramit, Sajee; Aboagye, Eric Ofori; Hajitou, Amin

    2018-04-21

    The previously developed adeno-associated virus/phage (AAVP) vector, a hybrid between M13 bacteriophage (phage) viruses that infect bacteria only and human Adeno-Associated Virus (AAV), is a promising tool in targeted gene therapy against cancer. AAVP can be administered systemically and made tissue specific through the use of ligand-directed targeting. Cancer cells and tumor-associated blood vessels overexpress the α ν integrin receptors, which are involved in tumor angiogenesis and tumor invasion. AAVP is targeted to these integrins via a double cyclic RGD4C ligand displayed on the phage capsid. Nevertheless, there remain significant host-defense hurdles to the use of AAVP in targeted gene delivery and subsequently in gene therapy. We previously reported that histone deacetylation in cancer constitutes a barrier to AAVP. Herein, to improve AAVP-mediated gene delivery to cancer cells, we combined the vector with selective adjuvant chemicals that inhibit specific histone deacetylases (HDAC). We examined the effects of the HDAC inhibitor C1A that mainly targets HDAC6 and compared this to sodium butyrate, a pan-HDAC inhibitor with broad spectrum HDAC inhibition. We tested the effects on melanoma, known for HDAC6 up-regulation, and compared this side by side with a normal human kidney HEK293 cell line. Varying concentrations were tested to determine cytotoxic levels as well as effects on AAVP gene delivery. We report that the HDAC inhibitor C1A increased AAVP-mediated transgene expression by up to ~9-fold. These findings indicate that selective HDAC inhibition is a promising adjuvant treatment for increasing the therapeutic value of AAVP.

  4. Effects of target typicality on categorical search.

    PubMed

    Maxfield, Justin T; Stalder, Westri D; Zelinsky, Gregory J

    2014-10-01

    The role of target typicality in a categorical visual search task was investigated by cueing observers with a target name, followed by a five-item target present/absent search array in which the target images were rated in a pretest to be high, medium, or low in typicality with respect to the basic-level target cue. Contrary to previous work, we found that search guidance was better for high-typicality targets compared to low-typicality targets, as measured by both the proportion of immediate target fixations and the time to fixate the target. Consistent with previous work, we also found an effect of typicality on target verification times, the time between target fixation and the search judgment; as target typicality decreased, verification times increased. To model these typicality effects, we trained Support Vector Machine (SVM) classifiers on the target categories, and tested these on the corresponding specific targets used in the search task. This analysis revealed significant differences in classifier confidence between the high-, medium-, and low-typicality groups, paralleling the behavioral results. Collectively, these findings suggest that target typicality broadly affects both search guidance and verification, and that differences in typicality can be predicted by distance from an SVM classification boundary. © 2014 ARVO.

  5. Effect of Biological Relatedness on Perfume Selection for Others: Preliminary Evidence.

    PubMed

    Sobotková, Markéta; Fialová, Jitka; Roberts, S Craig; Havlíček, Jan

    2017-01-01

    People tend to choose perfumes to complement their body odour. As kin share some body odour qualities, their ability to select complementary perfumes for relatives might be higher compared with selection for nonrelatives. We tested this in two studies, comparing selection of a perfume for a target man by himself and by either a familiar but unrelated individual (girlfriend; Study 1) or a relative (sister; Study 2). Target men applied the two perfumes (own or other's choice) to their axillae and then wore cotton pads for 12 hr. Collected perfume-body odour blends and perfumes alone were assessed by rater panels. In Study 1, the blends were rated as nominally more pleasant when body odours were mixed with the perfumes selected by girlfriends compared with those selected by target men themselves. In Study 2, body odours mixed with perfumes selected by sisters were rated significantly more attractive than those mixed with perfumes selected by target men. No significant differences were found for attractiveness and pleasantness ratings when perfumes were rated alone, suggesting that it was the resulting blends that were uniquely different. Our results indicate that sisters might be particularly tuned to select suitable perfumes for their siblings.

  6. Feasibility and safety of exercise stress testing using an anti-gravity treadmill with Tc-99m tetrofosmin single-photon emission computed tomography (SPECT) myocardial perfusion imaging: A pilot non-randomized controlled study.

    PubMed

    Daly, Patrick; Kayse, Regina; Rudick, Steven; Robbins, Nathan; Scheler, Jennifer; Harris, David; O'Donnell, Robert; Dwivedi, Alok K; Gerson, Myron C

    2017-08-31

    Exercise is the AHA/ACC guideline-recommended stress modality for myocardial perfusion imaging, but many patients are unable to exercise to target heart rate on a conventional treadmill. We examined the feasibility and safety of stress imaging using an anti-gravity treadmill in patients with perceived poor exercise capacity. 49 patients were recruited for stress testing by anti-gravity treadmill (n = 29) or to a regadenoson control group (n = 20). Seventeen anti-gravity test patients (59%) reached target heart rate obviating the need for a pharmacologic stress agent. Adverse effects of the anti-gravity treadmill were limited to minor muscle aches in 5 subjects. Stress myocardial perfusion image quality judged by 3 blinded readers on a 5-point scale was comparable for the anti-gravity treadmill (4.30 ± SD 0.87) vs pharmacologic stress (4.28 ± SD 0.66). Stress testing using an anti-gravity treadmill is feasible and may help some patients safely achieve target heart rate.

  7. Voluntary explicit versus involuntary conceptual memory are associated with dissociable fMRI responses in hippocampus, amygdala, and parietal cortex for emotional and neutral word pairs.

    PubMed

    Ramponi, Cristina; Barnard, Philip J; Kherif, Ferath; Henson, Richard N

    2011-08-01

    Although functional neuroimaging studies have supported the distinction between explicit and implicit forms of memory, few have matched explicit and implicit tests closely, and most of these tested perceptual rather than conceptual implicit memory. We compared event-related fMRI responses during an intentional test, in which a group of participants used a cue word to recall its associate from a prior study phase, with those in an incidental test, in which a different group of participants used the same cue to produce the first associate that came to mind. Both semantic relative to phonemic processing at study, and emotional relative to neutral word pairs, increased target completions in the intentional test, but not in the incidental test, suggesting that behavioral performance in the incidental test was not contaminated by voluntary explicit retrieval. We isolated the neural correlates of successful retrieval by contrasting fMRI responses to studied versus unstudied cues for which the equivalent "target" associate was produced. By comparing the difference in this repetition-related contrast across the intentional and incidental tests, we could identify the correlates of voluntary explicit retrieval. This contrast revealed increased bilateral hippocampal responses in the intentional test, but decreased hippocampal responses in the incidental test. A similar pattern in the bilateral amygdale was further modulated by the emotionality of the word pairs, although surprisingly only in the incidental test. Parietal regions, however, showed increased repetition-related responses in both tests. These results suggest that the neural correlates of successful voluntary explicit memory differ in directionality, even if not in location, from the neural correlates of successful involuntary implicit (or explicit) memory, even when the incidental test taps conceptual processes.

  8. Effects of aerosol-vapor JP-8 jet fuel on the functional observational battery, and learning and memory in the rat.

    PubMed

    Baldwin, C M; Houston, F P; Podgornik, M N; Young, R S; Barnes, C A; Witten, M L

    2001-01-01

    To determine whether JP-8 jet fuel affects parameters of the Functional Observational Battery (FOB), visual discrimination, or spatial learning and memory, the authors exposed groups of male Fischer Brown Norway hybrid rats for 28 d to aerosol/vapor-delivered JP-8, or to JP-8 followed by 15 min of aerosolized substance P analogue, or to sham-confined fresh room air. Behavioral testing was accomplished with the U.S. Environmental Protection Agency's Functional Observational Battery. The authors used the Morris swim task to test visual and spatial learning and memory testing. The spatial test included examination of memory for the original target location following 15 d of JP-8 exposure, as well as a 3-d new target location learning paradigm implemented the day that followed the final day of exposure. Only JP-8 exposed animals had significant weight loss by the 2nd week of exposure compared with JP-8 with substance P and control rats; this finding compares with those of prior studies of JP-8 jet fuel. Rats exposed to JP-8 with or without substance P exhibited significantly greater rearing and less grooming behavior over time than did controls during Functional Observational Battery open-field testing. Exposed rats also swam significantly faster than controls during the new target location training and testing, thus supporting the increased activity noted during Functional Observational Battery testing. There were no significant differences between the exposed and control groups' performances during acquisition, retention, or learning of the new platform location in either the visual discrimination or spatial version of the Morris swim task. The data suggest that although visual discrimination and spatial learning and memory were not disrupted by JP-8 exposure, arousal indices and activity measures were distinctly different in these animals.

  9. Knowledge and Outcome Measure of HbA1c Testing in Asian Indian Patients with Type 2 Diabetes from a Tertiary Care Center

    PubMed Central

    Kumpatla, Satyavani; Medempudi, Srikanth; Manoharan, Deepa; Viswanathan, Vijay

    2010-01-01

    Aim: HbA1c test is considered to be the reliable measure for evaluating long-term glycemic control in type 2 diabetes. The purpose of this study was to evaluate whether knowledge about HbA1c test is associated with a better glycemic control. Materials and Methods: We conducted a cross-sectional survey of 480 (M:F; 287:193) adults with type 2 diabetes attending a tertiary care center during a period of four months. Baseline demographic and clinical data of all the subjects was obtained. Subject’s knowledge about HbA1c test and their target goal was assessed using a questionnaire. Recent HbA1c results were obtained from medical records. Results: Seventy four per cent of the subjects had awareness about HbA1c test and about 43% of those who knew HbA1c test also knew their target goal. 33% remember their last HbA1c result. The mean A1C of Group A was significantly lower when compared with Group B (8.1 ± 1.7 vs 9.2 ± 1.9, P<0.0001). Group C had lower A1C levels compared to Group D (7.7 ± 1.4 vs 8.5 ± 1.9, p<0.0001). Patients who kept their HbA1c less than 7% were significantly higher in Group C than in Group D. (37.8 vs 12.7%, p<0.00001). Subjects had good glycemic control with increasing levels of awareness about HbA1c. Conclusion: Majority of the diabetic patients who attended the tertiary care center for diabetes care knew HbA1c test and half of them were aware about their target goal. Awareness about HbA1c had a positive impact on maintenance of better glycemic control. PMID:20922109

  10. Implementing and expanding HIV testing in immigrant populations in Europe: Comparing guideline's recommendations and expert's opinions.

    PubMed

    Álvarez-Del Arco, Débora; Monge, Susana; Rivero-Montesdeoca, Yaiza; Burns, Fiona; Noori, Teymur; Del Amo, Julia

    2017-01-01

    Immigrant populations, especially those from endemic countries, living in the European Union (EU) suffer a disproportionate burden of HIV, delayed diagnosis and poorer access to antiretroviral treatment. While International Organisations are developing recommendations aimed at increasing the uptake of HIV testing, the feasibility and real outcomes of these measures remain unexplored. The aim of this review was, firstly to identify the recommendations of the main International Organisations (IO) on HIV testing in immigrants. Secondly, to describe the challenges for implementing and expanding HIV testing and counselling interventions targeting immigrants by interviewing key informants. The importance of HIV testing in immigrants is discussed, along with the appropriateness of universal HIV testing approaches vs most at risk targeted approaches. Also addressed is, pre- and post-HIV test counselling characteristics and community initiatives suitable to reach this population and, finally the legal issues regarding access to treatment for illegal immigrants. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  11. Cost effectiveness of EML4-ALK fusion testing and first-line crizotinib treatment for patients with advanced ALK-positive non-small-cell lung cancer.

    PubMed

    Djalalov, Sandjar; Beca, Jaclyn; Hoch, Jeffrey S; Krahn, Murray; Tsao, Ming-Sound; Cutz, Jean-Claude; Leighl, Natasha B

    2014-04-01

    ALK-targeted therapy with crizotinib offers significant improvement in clinical outcomes for the treatment of EML4-ALK fusion-positive non-small-cell lung cancer (NSCLC). We estimated the cost effectiveness of EML4-ALK fusion testing in combination with targeted first-line crizotinib treatment in Ontario. A cost-effectiveness analysis was conducted using a Markov model from the Canadian Public health (Ontario) perspective and a lifetime horizon in patients with stage IV NSCLC with nonsquamous histology. Transition probabilities and mortality rates were calculated from the Ontario Cancer Registry and Cancer Care Ontario New Drug Funding Program (CCO NDFP). Costs were obtained from the Ontario Case Costing Initiative, CCO NDFP, University Health Network, and literature. Molecular testing with first-line targeted crizotinib treatment in the population with advanced nonsquamous NSCLC resulted in a gain of 0.011 quality-adjusted life-years (QALYs) compared with standard care. The incremental cost was Canadian $2,725 per patient, and the incremental cost-effectiveness ratio (ICER) was $255,970 per QALY gained. Among patients with known EML4-ALK-positive advanced NSCLC, first-line crizotinib therapy provided 0.379 additional QALYs, cost an additional $95,043 compared with standard care, and produced an ICER of $250,632 per QALY gained. The major driver of cost effectiveness was drug price. EML4-ALK fusion testing in stage IV nonsquamous NSCLC with crizotinib treatment for ALK-positive patients is not cost effective in the setting of high drug costs and a low biomarker frequency in the population.

  12. Bullets versus burgers: is it threat or relevance that captures attention?

    PubMed

    de Oca, Beatrice M; Black, Alison A

    2013-01-01

    Previous studies have found that potentially dangerous stimuli are better at capturing attention than neutral stimuli, a finding sometimes called the threat superiority effect. However, non-threatening stimuli also capture attention in many studies of visual attention. In Experiment 1, the relevance superiority effect was tested with a visual search task comparing detection times for threatening stimuli (guns), pleasant but motivationally relevant stimuli (food), and neutral stimuli (flowers and chairs). Gun targets were detected more rapidly than both types of neutral targets, whereas food targets were detected more quickly than the neutral chair targets only. Guns were detected more rapidly than food. In Experiment 2, threatening targets (guns and snakes), pleasant but motivationally relevant targets (money and food), and neutral targets (trees and couches) were all presented with the same neutral distractors (cactus and pots) in order to control for the valence of the distractor stimulus across the three categories of target stimuli. Threatening and pleasant target categories facilitated attention relative to neutral targets. The results support the view that both threatening and pleasant pictures can be detected more rapidly than neutral targets.

  13. Reality-based practice under pressure improves handgun shooting performance of police officers.

    PubMed

    Oudejans, R R D

    2008-03-01

    The current study examined whether reality-based practice under pressure may help in preventing degradation of handgun shooting performance under pressure for police officers. Using a pre-post-test design, one group of nine police officers practised handgun shooting under pressure evoked by an opponent who also fired back using marking (coloured soap) cartridges. The control group (n = 8) practised handgun shooting on standard cardboard targets instead of real opponents. Within a fortnight after the pre-test, both groups received three training sessions of 1 h, in which each person fired a total of 72 rounds. During the pre- and post test each participant took 30 shots without pressure (cardboard targets) and 30 shots under additional pressure (with an opponent firing back). While during the pre-test both groups performed worse in front of an opponent firing back compared to the cardboard targets, after the training sessions shooting performance of the experimental group no longer deteriorated with an opponent while performance of the control group was equally harmed as during the pre-test. These results indicate that training exercises involving increased pressure can acclimatize shooting performance of ordinary police officers to those situations with elevated pressure that they may encounter during their police work.

  14. Epidemiology of Hepatitis C Virus in Pennsylvania State Prisons, 2004–2012: Limitations of 1945–1965 Birth Cohort Screening in Correctional Settings

    PubMed Central

    Mahowald, Madeline K.; Scharff, Nicholas; Flanigan, Timothy P.; Beckwith, Curt G.; Zaller, Nickolas D.

    2014-01-01

    Objectives. We described hepatitis C virus antibody (anti-HCV) prevalence in a state prison system and retrospectively evaluated the case-finding performance of targeted testing of the 1945 to 1965 birth cohort in this population. Methods. We used observational data from universal testing of Pennsylvania state prison entrants (June 2004–December 2012) to determine anti-HCV prevalence by birth cohort. We compared anti-HCV prevalence and the burden of anti-HCV in the 1945 to 1965 birth cohort with that in all other birth years. Results. Anti-HCV prevalence among 101 727 adults entering prison was 18.1%. Prevalence was highest among those born from 1945 to 1965, but most anti-HCV cases were in people born after 1965. Targeted testing of the 1945 to 1965 birth cohort would have identified a decreasing proportion of cases with time. Conclusions. HCV is endemic in correctional populations. Targeted testing of the 1945 to 1965 birth cohort would produce a high yield of positive test results but would identify only a minority of cases. We recommend universal anti-HCV screening in correctional settings to allow for maximum case identification, secondary prevention, and treatment of affected prisoners. PMID:24825235

  15. Radioactive ion beams produced by neutron-induced fission at ISOLDE

    NASA Astrophysics Data System (ADS)

    Catherall, R.; Lettry, J.; Gilardoni, S.; Köster, U.; Isolde Collaboration

    2003-05-01

    The production rates of neutron-rich fission products for the next-generation radioactive beam facility EURISOL [EU-RTD Project EURISOL (HPRI-CT-1999-50001)] are mainly limited by the maximum amount of power deposited by protons in the target. An alternative approach is to use neutron beams to induce fission in actinide targets. This has the advantage of reducing: the energy deposited by the proton beam in the target; contamination from neutron-deficient isobars that would be produced by spallation; and mechanical stress on the target. At ISOLDE CERN [E. Kugler, Hyperfine Interact. 129 (2000) 23], tests have been made on standard ISOLDE actinide targets using fast-neutron bunches produced by bombarding thick, high- Z metal converters with 1 and 1.4 GeV proton pulses. This paper reviews the first applications of converters used at ISOLDE. It highlights the different geometries and the techniques used to compare fission yields produced by the proton beam directly on the target with neutron-induced fission. Results from the six targets already tested, namely UC 2/graphite and ThO 2 targets with tungsten and tantalum converters, are presented. To gain further knowledge for the design of a dedicated target as required by the TARGISOL project [EU-RTD Project TARGISOL (HPRI-CT-2001-50033)], the results are compared to simulations, using the MARS [N.V. Mokhov, S.I. Striganov, A. Van Ginneken, S.G. Mashnik, A.J. Sierk, J. Ranft, MARS code developments, in: 4th Workshop on Simulating Accelerator Radiation Environments, SARE-4, Knoxville, USA, 14-15.9.1998, FERMILAB-PUB-98-379, nucl-th/9812038; N.V. Mokhov, The Mars Code System User's Guide, Fermilab-FN-628, 1995; N.V. Mokhov, MARS Code Developments, Benchmarking and Applications, Fermilab-Conf-00-066, 2000; O.E. Krivosheev, N.V. Mokhov, A New MARS and its Applications, Fermilab-Conf-98/43, 1998] code interfaced with MCNP [J.S. Hendrics, MCNP4C LANL Memo X-5; JSH-2000-3; J.F. Briemesteir (Ed.), MCNP - A General Montecarlo N-Particle Transport Code, Version 4C, LA-13709-M] libraries, of the neutron flux from the converters interacting with the actinide targets.

  16. Radioactive ion beams produced by neutron-induced fission at ISOLDE

    NASA Astrophysics Data System (ADS)

    Isolde Collaboration; Catherall, R.; Lettry, J.; Gilardoni, S.; Köster, U.

    2003-05-01

    The production rates of neutron-rich fission products for the next-generation radioactive beam facility EURISOL [EU-RTD Project EURISOL (HPRI-CT-1999-50001)] are mainly limited by the maximum amount of power deposited by protons in the target. An alternative approach is to use neutron beams to induce fission in actinide targets. This has the advantage of reducing: the energy deposited by the proton beam in the target; contamination from neutron-deficient isobars that would be produced by spallation; and mechanical stress on the target. At ISOLDE CERN [E. Kugler, Hyperfine Interact. 129 (2000) 23], tests have been made on standard ISOLDE actinide targets using fast-neutron bunches produced by bombarding thick, high-/Z metal converters with 1 and 1.4 GeV proton pulses. This paper reviews the first applications of converters used at ISOLDE. It highlights the different geometries and the techniques used to compare fission yields produced by the proton beam directly on the target with neutron-induced fission. Results from the six targets already tested, namely UC2/graphite and ThO2 targets with tungsten and tantalum converters, are presented. To gain further knowledge for the design of a dedicated target as required by the TARGISOL project [EU-RTD Project TARGISOL (HPRI-CT-2001-50033)], the results are compared to simulations, using the MARS [N.V. Mokhov, S.I. Striganov, A. Van Ginneken, S.G. Mashnik, A.J. Sierk, J. Ranft, MARS code developments, in: 4th Workshop on Simulating Accelerator Radiation Environments, SARE-4, Knoxville, USA, 14-15.9.1998, FERMILAB-PUB-98-379, nucl-th/9812038; N.V. Mokhov, The Mars Code System User's Guide, Fermilab-FN-628, 1995; N.V. Mokhov, MARS Code Developments, Benchmarking and Applications, Fermilab-Conf-00-066, 2000; O.E. Krivosheev, N.V. Mokhov, A New MARS and its Applications, Fermilab-Conf-98/43, 1998] code interfaced with MCNP [J.S. Hendrics, MCNP4C LANL Memo X-5; JSH-2000-3; J.F. Briemesteir (Ed.), MCNP - A General Montecarlo N-Particle Transport Code, Version 4C, LA-13709-M] libraries, of the neutron flux from the converters interacting with the actinide targets.

  17. Hybrid analysis of multiaxis electromagnetic data for discrimination of munitions and explosives of concern

    USGS Publications Warehouse

    Friedel, M.J.; Asch, T.H.; Oden, C.

    2012-01-01

    The remediation of land containing munitions and explosives of concern, otherwise known as unexploded ordnance, is an ongoing problem facing the U.S. Department of Defense and similar agencies worldwide that have used or are transferring training ranges or munitions disposal areas to civilian control. The expense associated with cleanup of land previously used for military training and war provides impetus for research towards enhanced discrimination of buried unexploded ordnance. Towards reducing that expense, a multiaxis electromagnetic induction data collection and software system, called ALLTEM, was designed and tested with support from the U.S. Department of Defense Environmental Security Technology Certification Program. ALLTEM is an on-time time-domain system that uses a continuous triangle-wave excitation to measure the target-step response rather than traditional impulse response. The system cycles through three orthogonal transmitting loops and records a total of 19 different transmitting and receiving loop combinations with a nominal spatial data sampling interval of 20 cm. Recorded data are pre-processed and then used in a hybrid discrimination scheme involving both data-driven and numerical classification techniques. The data-driven classification scheme is accomplished in three steps. First, field observations are used to train a type of unsupervised artificial neural network, a self-organizing map (SOM). Second, the SOM is used to simultaneously estimate target parameters (depth, azimuth, inclination, item type and weight) by iterative minimization of the topographic error vectors. Third, the target classification is accomplished by evaluating histograms of the estimated parameters. The numerical classification scheme is also accomplished in three steps. First, the Biot–Savart law is used to model the primary magnetic fields from the transmitter coils and the secondary magnetic fields generated by currents induced in the target materials in the ground. Second, the target response is modelled by three orthogonal dipoles from prolate, oblate and triaxial ellipsoids with one long axis and two shorter axes. Each target consists of all three dipoles. Third, unknown target parameters are determined by comparing modelled to measured target responses. By comparing the rms error among the self-organizing map and numerical classification results, we achieved greater than 95 per cent detection and correct classification of the munitions and explosives of concern at the direct fire and indirect fire test areas at the UXO Standardized Test Site at the Aberdeen Proving Ground, Maryland in 2010.

  18. Hybrid analysis of multiaxis electromagnetic data for discrimination of munitions and explosives of concern

    NASA Astrophysics Data System (ADS)

    Friedel, M. J.; Asch, T. H.; Oden, C.

    2012-08-01

    The remediation of land containing munitions and explosives of concern, otherwise known as unexploded ordnance, is an ongoing problem facing the U.S. Department of Defense and similar agencies worldwide that have used or are transferring training ranges or munitions disposal areas to civilian control. The expense associated with cleanup of land previously used for military training and war provides impetus for research towards enhanced discrimination of buried unexploded ordnance. Towards reducing that expense, a multiaxis electromagnetic induction data collection and software system, called ALLTEM, was designed and tested with support from the U.S. Department of Defense Environmental Security Technology Certification Program. ALLTEM is an on-time time-domain system that uses a continuous triangle-wave excitation to measure the target-step response rather than traditional impulse response. The system cycles through three orthogonal transmitting loops and records a total of 19 different transmitting and receiving loop combinations with a nominal spatial data sampling interval of 20 cm. Recorded data are pre-processed and then used in a hybrid discrimination scheme involving both data-driven and numerical classification techniques. The data-driven classification scheme is accomplished in three steps. First, field observations are used to train a type of unsupervised artificial neural network, a self-organizing map (SOM). Second, the SOM is used to simultaneously estimate target parameters (depth, azimuth, inclination, item type and weight) by iterative minimization of the topographic error vectors. Third, the target classification is accomplished by evaluating histograms of the estimated parameters. The numerical classification scheme is also accomplished in three steps. First, the Biot-Savart law is used to model the primary magnetic fields from the transmitter coils and the secondary magnetic fields generated by currents induced in the target materials in the ground. Second, the target response is modelled by three orthogonal dipoles from prolate, oblate and triaxial ellipsoids with one long axis and two shorter axes. Each target consists of all three dipoles. Third, unknown target parameters are determined by comparing modelled to measured target responses. By comparing the rms error among the self-organizing map and numerical classification results, we achieved greater than 95 per cent detection and correct classification of the munitions and explosives of concern at the direct fire and indirect fire test areas at the UXO Standardized Test Site at the Aberdeen Proving Ground, Maryland in 2010.

  19. Limited generalization with varied, as compared to specific, practice in short-term motor learning.

    PubMed

    Willey, Chéla R; Liu, Zili

    2018-01-01

    The schema theory of learning predicts that varied training in motor learning should give rise to better transfer than specific training. For example, throwing beanbags during practice to targets 5 and 9ft away should better generalize to targets 7 and 11ft away, as compared to only throwing to a target 7ft away. In this study, we tested this prediction in a throwing task, when the pretest, practice, and posttest were all completed within an hour. Participants in the varied group practiced throwing at 5 and 9ft targets, while participants in the specific group practiced throwing at 7ft only. All participants reliably reduced errors from pretest to posttest. The varied group never outperformed the specific group at the 7ft target (the trained target for the specific group). They did not reliably outperform the specific group at 11ft, either. The numerically better performance at 11ft by the varied group was due, as it turned out in a subsequent experiment, to the fact that 11ft was closer to 9ft (one of the two training targets for the varied group) than to 7ft (the training target for the specific group). We conclude that varied training played a very limited role in short-term motor learning. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Target-oriented imaging of hydraulic fractures by applying the staining algorithm for downhole microseismic migration

    NASA Astrophysics Data System (ADS)

    Lin, Ye; Zhang, Haijiang; Jia, Xiaofeng

    2018-03-01

    For microseismic monitoring of hydraulic fracturing, microseismic migration can be used to image the fracture network with scattered microseismic waves. Compared with conventional microseismic location-based fracture characterization methods, microseismic migration can better constrain the stimulated reservoir volume regardless of the completeness of detected and located microseismic sources. However, the imaging results from microseismic migration may suffer from the contamination of other structures and thus the target fracture zones may not be illuminated properly. To solve this issue, in this study we propose a target-oriented staining algorithm for microseismic reverse-time migration. In the staining algorithm, the target area is first stained by constructing an imaginary velocity field and then a synchronized source wavefield only concerning the target structure is produced. As a result, a synchronized image from imaging with the synchronized source wavefield mainly contains the target structures. Synthetic tests based on a downhole microseismic monitoring system show that the target-oriented microseismic reverse-time migration method improves the illumination of target areas.

  1. Earth orbital teleoperator manipulator system evaluation program

    NASA Technical Reports Server (NTRS)

    Brye, R. G.; Frederick, P. N.; Kirkpatrick, M., III; Shields, N. L., Jr.

    1977-01-01

    The operator's ability to perform five manipulator tip movements while using monoptic and stereoptic video systems was assessed. Test data obtained were compared with previous results to determine the impact of camera placement and stereoptic viewing on manipulator system performance. The tests were performed using the NASA MSFC extendible stiff arm Manipulator and an analog joystick controller. Two basic manipulator tasks were utilized. The minimum position change test required the operator to move the manipulator arm to touch a target contract. The dexterity test required removal and replacement of pegs.

  2. CETSA screening identifies known and novel thymidylate synthase inhibitors and slow intracellular activation of 5-fluorouracil

    PubMed Central

    Almqvist, Helena; Axelsson, Hanna; Jafari, Rozbeh; Dan, Chen; Mateus, André; Haraldsson, Martin; Larsson, Andreas; Molina, Daniel Martinez; Artursson, Per; Lundbäck, Thomas; Nordlund, Pär

    2016-01-01

    Target engagement is a critical factor for therapeutic efficacy. Assessment of compound binding to native target proteins in live cells is therefore highly desirable in all stages of drug discovery. We report here the first compound library screen based on biophysical measurements of intracellular target binding, exemplified by human thymidylate synthase (TS). The screen selected accurately for all the tested known drugs acting on TS. We also identified TS inhibitors with novel chemistry and marketed drugs that were not previously known to target TS, including the DNA methyltransferase inhibitor decitabine. By following the cellular uptake and enzymatic conversion of known drugs we correlated the appearance of active metabolites over time with intracellular target engagement. These data distinguished a much slower activation of 5-fluorouracil when compared with nucleoside-based drugs. The approach establishes efficient means to associate drug uptake and activation with target binding during drug discovery. PMID:27010513

  3. Light Video Game Play is Associated with Enhanced Visual Processing of Rapid Serial Visual Presentation Targets.

    PubMed

    Howard, Christina J; Wilding, Robert; Guest, Duncan

    2017-02-01

    There is mixed evidence that video game players (VGPs) may demonstrate better performance in perceptual and attentional tasks than non-VGPs (NVGPs). The rapid serial visual presentation task is one such case, where observers respond to two successive targets embedded within a stream of serially presented items. We tested light VGPs (LVGPs) and NVGPs on this task. LVGPs were better at correct identification of second targets whether they were also attempting to respond to the first target. This performance benefit seen for LVGPs suggests enhanced visual processing for briefly presented stimuli even with only very moderate game play. Observers were less accurate at discriminating the orientation of a second target within the stream if it occurred shortly after presentation of the first target, that is to say, they were subject to the attentional blink (AB). We find no evidence for any reduction in AB in LVGPs compared with NVGPs.

  4. Can Monkeys (Macaca mulatta) Represent Invisible Displacement?

    NASA Technical Reports Server (NTRS)

    Filion, Christine M.; Washburn, David A.; Gulledge, Jonathan P.

    1996-01-01

    Four experiments were conducted to assess whether or not rhesus macaques (Macaca mulatta) could represent the unperceived movements of a stimulus. Subjects were tested on 2 computerized tasks, HOLE (monkeys) and LASER (humans and monkeys), in which subjects needed to chase or shoot at, respectively, a moving target that either remained visible or became invisible for a portion of its path of movement. Response patterns were analyzed and compared between target-visible and target-invisible conditions. Results of Experiments 1, 2, and 3 demonstrated that the monkeys are capable of extrapolating movement. That this extrapolation involved internal representation of the target's invisible movement was suggested but not confirmed. Experiment 4, however, demonstrated that the monkeys are capable of representing the invisible displacements of a stimulus.

  5. Multi-laboratory evaluations of the performance of Catellicoccus marimammalium PCR assays developed to target gull fecal sources

    USGS Publications Warehouse

    Sinigalliano, Christopher D.; Ervin, Jared S.; Van De Werfhorst, Laurie C.; Badgley, Brian D.; Ballestée, Elisenda; Bartkowiaka, Jakob; Boehm, Alexandria B.; Byappanahalli, Muruleedhara N.; Goodwin, Kelly D.; Gourmelon, Michèle; Griffith, John; Holden, Patricia A.; Jay, Jenny; Layton, Blythe; Lee, Cheonghoon; Lee, Jiyoung; Meijer, Wim G.; Noble, Rachel; Raith, Meredith; Ryu, Hodon; Sadowsky, Michael J.; Schriewer, Alexander; Wang, Dan; Wanless, David; Whitman, Richard; Wuertz, Stefan; Santo Domingo, Jorge W.

    2013-01-01

    Here we report results from a multi-laboratory (n = 11) evaluation of four different PCR methods targeting the 16S rRNA gene of Catellicoccus marimammalium originally developed to detect gull fecal contamination in coastal environments. The methods included a conventional end-point PCR method, a SYBR® Green qPCR method, and two TaqMan® qPCR methods. Different techniques for data normalization and analysis were tested. Data analysis methods had a pronounced impact on assay sensitivity and specificity calculations. Across-laboratory standardization of metrics including the lower limit of quantification (LLOQ), target detected but not quantifiable (DNQ), and target not detected (ND) significantly improved results compared to results submitted by individual laboratories prior to definition standardization. The unit of measure used for data normalization also had a pronounced effect on measured assay performance. Data normalization to DNA mass improved quantitative method performance as compared to enterococcus normalization. The MST methods tested here were originally designed for gulls but were found in this study to also detect feces from other birds, particularly feces composited from pigeons. Sequencing efforts showed that some pigeon feces from California contained sequences similar to C. marimammalium found in gull feces. These data suggest that the prevalence, geographic scope, and ecology of C. marimammalium in host birds other than gulls require further investigation. This study represents an important first step in the multi-laboratory assessment of these methods and highlights the need to broaden and standardize additional evaluations, including environmentally relevant target concentrations in ambient waters from diverse geographic regions.

  6. Visuo-oculomotor skills related to the visual demands of sporting environments.

    PubMed

    Ceyte, Hadrien; Lion, Alexis; Caudron, Sébastien; Perrin, Philippe; Gauchard, Gérome C

    2017-01-01

    The aim of this study was to assess the visuo-oculomotor skills of gaze orientation in selected sport activities relative to visual demands of the sporting environment. Both temporal and spatial demands of the sporting environment were investigated: The latency and accuracy of horizontal saccades and the gain of the horizontal smooth pursuit of the sporting environment were investigated in 16 fencers, 19 tennis players, 12 gymnasts, 9 swimmers and 18 sedentary participants. For the saccade test, two sequences were tested: In the fixed sequence, participants knew in advance the time interval between each target, as well as the direction and the amplitude of its reappearance; in the Freyss sequence however, the spatial changes of the target (direction and amplitude) were known in advance by participants but the time interval between each target was unknown. For the smooth-pursuit test, participants were instructed to smoothly track a target moving in a predictable sinusoidal, horizontal way without corrective ocular saccades, nor via anticipation or head movements. The results showed no significant differences between specificities of selected sporting activities via the saccade latency (although shorter than in non-athletes), contrary to saccade accuracy and the gain of smooth pursuit. Higher saccade accuracy was observed overall in fencers compared to non-athletes and all other sportsmen with the exception of tennis players. In the smooth-pursuit task, only tennis players presented a significantly higher gain compared to non-athletes and gymnasts. These sport-specific characteristics of the visuo-oculomotor skills are discussed with regard to the different cognitive skills such as attentional allocation and cue utilization ability as well as with regard to the difference in motor preparation.

  7. Odor Perception by Dogs: Evaluating Two Training Approaches for Odor Learning of Sniffer Dogs.

    PubMed

    Fischer-Tenhagen, Carola; Johnen, Dorothea; Heuwieser, Wolfgang; Becker, Roland; Schallschmidt, Kristin; Nehls, Irene

    2017-06-01

    In this study, a standardized experimental set-up with various combinations of herbs as odor sources was designed. Two training approaches for sniffer dogs were compared; first, training with a pure reference odor, and second, training with a variety of odor mixtures with the target odor as a common denominator. The ability of the dogs to identify the target odor in a new context was tested. Six different herbs (basil, St. John's wort, dandelion, marjoram, parsley, ribwort) were chosen to produce reference materials in various mixtures with (positive) and without (negative) chamomile as the target odor source. The dogs were trained to show 1 of 2 different behaviors, 1 for the positive, and 1 for the negative sample as a yes/no task. Tests were double blind with one sample presented at a time. In both training approaches, dogs were able to detect chamomile as the target odor in any presented mixture with an average sensitivity of 72% and a specificity of 84%. Dogs trained with odor mixture containing the target odor had more correct indications in the transfer task. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. VHF/UHF imagery and RCS measurements of ground targets in forested terrain

    NASA Astrophysics Data System (ADS)

    Gatesman, Andrew J.; Beaudoin, Christopher J.; Giles, Robert H.; Waldman, Jerry; Nixon, William E.

    2002-08-01

    The monostatic VV and HH-polarized radar signatures of several targets and trees have been measured at foliage penetration frequencies (VHF/UHF) by using 1/35th scale models and an indoor radar range operating at X-band. An array of high-fidelity scale model ground vehicles and test objects as well as scaled ground terrain and trees have been fabricated for the study. Radar measurement accuracy has been confirmed by comparing the signature of a test object with a method of moments radar cross section prediction code. In addition to acquiring signatures of targets located on a smooth, dielectric ground plane, data have also been acquired with targets located in simulated wooded terrain that included scaled tree trunks and tree branches. In order to assure the correct backscattering behavior, all dielectric properties of live tree wood and moist soil were scaled properly to match the complex dielectric constant of the full-scale materials. The impact of the surrounding tree clutter on the VHF/UHF radar signatures of ground vehicles was accessed. Data were processed into high-resolution, polar-formatted ISAR imagery and signature comparisons are made between targets in open-field and forested scenarios.

  9. Using Reactive Transport Modeling to Understand Formation of the Stimson Sedimentary Unit and Altered Fracture Zones at Gale Crater, Mars

    NASA Technical Reports Server (NTRS)

    Hausrath, E. M.; Ming, D. W.; Peretyazhko, T.; Rampe, E. B.

    2017-01-01

    Water flowing through sediments at Gale Crater, Mars created environments that were likely habitable, and sampled basin-wide hydrological systems. However, many questions remain about these environments and the fluids that generated them. Measurements taken by the Mars Science Laboratory Curiosity of multiple fracture zones can help constrain the environments that formed them because they can be compared to nearby associated parent material (Figure 1). For example, measurements of altered fracture zones from the target Greenhorn in the Stimson sandstone can be compared to parent material measured in the nearby Big Sky target, allowing constraints to be placed on the alteration conditions that formed the Greenhorn target from the Big Sky target. Similarly, CheMin measurements of the powdered < 150 micron fraction from the drillhole at Big Sky and sample from the Rocknest eolian deposit indicate that the mineralogies are strikingly similar. The main differences are the presence of olivine in the Rocknest eolian deposit, which is absent in the Big Sky target, and the presence of far more abundant Fe oxides in the Big Sky target. Quantifying the changes between the Big Sky target and the Rocknest eolian deposit can therefore help us understand the diagenetic changes that occurred forming the Stimson sedimentary unit. In order to interpret these aqueous changes, we performed reactive transport modeling of 1) the formation of the Big Sky target from a Rocknest eolian deposit-like parent material, and 2) the formation of the Greenhorn target from the Big Sky target. This work allows us to test the relationships between the targets and the characteristics of the aqueous conditions that formed the Greenhorn target from the Big Sky target, and the Big Sky target from a Rocknest eolian deposit-like parent material.

  10. SDSS-IV eBOSS emission-line galaxy pilot survey

    DOE PAGES

    Comparat, J.; Delubac, T.; Jouvel, S.; ...

    2016-08-09

    The Sloan Digital Sky Survey IV extended Baryonic Oscillation Spectroscopic Survey (SDSS-IV/eBOSS) will observe 195,000 emission-line galaxies (ELGs) to measure the Baryonic Acoustic Oscillation standard ruler (BAO) at redshift 0.9. To test different ELG selection algorithms, 9,000 spectra were observed with the SDSS spectrograph as a pilot survey based on data from several imaging surveys. First, using visual inspection and redshift quality flags, we show that the automated spectroscopic redshifts assigned by the pipeline meet the quality requirements for a reliable BAO measurement. We also show the correlations between sky emission, signal-to-noise ratio in the emission lines, and redshift error.more » Then we provide a detailed description of each target selection algorithm we tested and compare them with the requirements of the eBOSS experiment. As a result, we provide reliable redshift distributions for the different target selection schemes we tested. Lastly, we determine an target selection algorithms that is best suited to be applied on DECam photometry because they fulfill the eBOSS survey efficiency requirements.« less

  11. An optimal controller for an electric ventricular-assist device: theory, implementation, and testing.

    PubMed

    Klute, G K; Tasch, U; Geselowitz, D B

    1992-04-01

    This paper addresses the development and testing of an optimal position feedback controller for the Penn State electric ventricular-assist device (EVAD). The control law is designed to minimize the expected value of the EVAD's power consumption for a targeted patient population. The closed-loop control law is implemented on an Intel 8096 microprocessor and in vitro test runs show that this controller improves the EVAD's efficiency by 15-21%, when compared with the performance of the currently used feedforward control scheme.

  12. Pilot study of a brief intervention based on the theory of planned behaviour and self-identity to increase chlamydia testing among young people living in deprived areas.

    PubMed

    Booth, Amy R; Norman, Paul; Goyder, Elizabeth; Harris, Peter R; Campbell, Michael J

    2014-09-01

    This study sought to estimate the effects of a novel intervention, compared with usual chlamydia testing promotion, on chlamydia test uptake and intentions among young people living in deprived areas. The intervention was based on the theory of planned behaviour, augmented with self-identity, and targeted the significant predictors of chlamydia testing intentions identified in the previous research. Cluster randomization was used to allocate college tutor groups (intervention n = 10; control n = 11) to the intervention or control group. The sample comprised 253 participants (intervention n = 145, control n = 108). The primary outcome was test offer uptake at the end of the session. Other outcomes measured at immediate follow-up were intention, attitude, subjective norm, perceived behavioural control, and self-identity. Generalized estimating equations, controlling for cluster effects and sexual activity, found a small but non-significant effect of condition on test offer uptake, OR = 1.65 (95% CI 0.70, 3.88) p = .25, with 57.5% of intervention participants accepting the offer of a test compared with 40.2% of control participants. Using the same analysis procedure, small-to-medium intervention effects were found on other outcome variables, including a significant effect on attitudes towards chlamydia testing, OR = 1.37 (95% CI 1.00, 1.87), p = .05. The results provide encouraging initial evidence that this theory-based intervention, targeting the key determinants of chlamydia testing, may help to improve chlamydia testing uptake in a high-risk group. They support the conduct of a larger trial to evaluate the effectiveness of the intervention. What is already known on this subject? Young people living in areas of increased socio-economic deprivation have been identified as a high-risk group for chlamydia. Previous research within an extended model of the theory of planned behaviour (TPB) found that attitude, subjective norm, perceived behavioural control, and self-identity all significantly predicted chlamydia testing intentions in this high-risk group. What does this study add? Development and testing of a novel, TPB-based intervention targeting predictors of chlamydia testing intentions. The intervention led to significantly more positive attitudes towards chlamydia testing. Preliminary indication that a TPB-based intervention may help to improve chlamydia testing in a high-risk group. © 2013 The British Psychological Society.

  13. Mutagenicity testing with transgenic mice. Part I: Comparison with the mouse bone marrow micronucleus test

    PubMed Central

    Wahnschaffe, U; Bitsch, A; Kielhorn, J; Mangelsdorf, I

    2005-01-01

    As part of a larger literature study on transgenic animals in mutagenicity testing, test results from the transgenic mutagenicity assays (lacI model; commercially available as the Big Blue® mouse, and the lacZ model; commercially available as the Muta™Mouse), were compared with the results on the same substances in the more traditional mouse bone marrow micronucleus test. 39 substances were found which had been tested in the micronucleus assay and in the above transgenic mouse systems. Although, the transgenic animal mutation assay is not directly comparable with the micronucleus test, because different genetic endpoints are examined: chromosome aberration versus gene mutation, the results for the majority of substances were in agreement. Both test systems, the transgenic mouse assay and the mouse bone marrow micronucleus test, have advantages and they complement each other. However, the transgenic animal assay has some distinct advantages over the micronucleus test: it is not restricted to one target organ and detects systemic as well as local mutagenic effects. PMID:15655069

  14. Comparison of composite prostate radiotherapy plan doses with dependent and independent boost phases.

    PubMed

    Narayanasamy, Ganesh; Avila, Gabrielle; Mavroidis, Panayiotis; Papanikolaou, Niko; Gutierrez, Alonso; Baacke, Diana; Shi, Zheng; Stathakis, Sotirios

    2016-09-01

    Prostate cases commonly consist of dual phase planning with a primary plan followed by a boost. Traditionally, the boost phase is planned independently from the primary plan with the risk of generating hot or cold spots in the composite plan. Alternatively, boost phase can be planned taking into account the primary dose. The aim of this study was to compare the composite plans from independently and dependently planned boosts using dosimetric and radiobiological metrics. Ten consecutive prostate patients previously treated at our institution were used to conduct this study on the Raystation™ 4.0 treatment planning system. For each patient, two composite plans were developed: a primary plan with an independently planned boost and a primary plan with a dependently planned boost phase. The primary plan was prescribed to 54 Gy in 30 fractions to the primary planning target volume (PTV1) which includes prostate and seminal vesicles, while the boost phases were prescribed to 24 Gy in 12 fractions to the boost planning target volume (PTV2) that targets only the prostate. PTV coverage, max dose, median dose, target conformity, dose homogeneity, dose to OARs, and probabilities of benefit, injury, and complication-free tumor control (P+) were compared. Statistical significance was tested using either a 2-tailed Student's t-test or Wilcoxon signed-rank test. Dosimetrically, the composite plan with dependent boost phase exhibited smaller hotspots, lower maximum dose to the target without any significant change to normal tissue dose. Radiobiologically, for all but one patient, the percent difference in the P+ values between the two methods was not significant. A large percent difference in P+ value could be attributed to an inferior primary plan. The benefits of considering the dose in primary plan while planning the boost is not significant unless a poor primary plan was achieved.

  15. Measurements and parameterization of neutron energy spectra from targets bombarded with 120 GeV protons

    NASA Astrophysics Data System (ADS)

    Kajimoto, T.; Shigyo, N.; Sanami, T.; Iwamoto, Y.; Hagiwara, M.; Lee, H. S.; Soha, A.; Ramberg, E.; Coleman, R.; Jensen, D.; Leveling, A.; Mokhov, N. V.; Boehnlein, D.; Vaziri, K.; Sakamoto, Y.; Ishibashi, K.; Nakashima, H.

    2014-10-01

    The energy spectra of neutrons were measured by a time-of-flight method for 120 GeV protons on thick graphite, aluminum, copper, and tungsten targets with an NE213 scintillator at the Fermilab Test Beam Facility. Neutron energy spectra were obtained between 25 and 3000 MeV at emission angles of 30°, 45°, 120°, and 150°. The spectra were parameterized as neutron emissions from three moving sources and then compared with theoretical spectra calculated by PHITS and FLUKA codes. The yields of the theoretical spectra were substantially underestimated compared with the yields of measured spectra. The integrated neutron yields from 25 to 3000 MeV calculated with PHITS code were 16-36% of the experimental yields and those calculated with FLUKA code were 26-57% of the experimental yields for all targets and emission angles.

  16. A HWIL test facility of infrared imaging laser radar using direct signal injection

    NASA Astrophysics Data System (ADS)

    Wang, Qian; Lu, Wei; Wang, Chunhui; Wang, Qi

    2005-01-01

    Laser radar has been widely used these years and the hardware-in-the-loop (HWIL) testing of laser radar become important because of its low cost and high fidelity compare with On-the-Fly testing and whole digital simulation separately. Scene generation and projection two key technologies of hardware-in-the-loop testing of laser radar and is a complicated problem because the 3D images result from time delay. The scene generation process begins with the definition of the target geometry and reflectivity and range. The real-time 3D scene generation computer is a PC based hardware and the 3D target models were modeled using 3dsMAX. The scene generation software was written in C and OpenGL and is executed to extract the Z-buffer from the bit planes to main memory as range image. These pixels contain each target position x, y, z and its respective intensity and range value. Expensive optical injection technologies of scene projection such as LDP array, VCSEL array, DMD and associated scene generation is ongoing. But the optical scene projection is complicated and always unaffordable. In this paper a cheaper test facility was described that uses direct electronic injection to provide rang images for laser radar testing. The electronic delay and pulse shaping circuits inject the scenes directly into the seeker's signal processing unit.

  17. Exploring the costs and outcomes of sexually transmitted infection (STI) screening interventions targeting men in football club settings: preliminary cost-consequence analysis of the SPORTSMART pilot randomised controlled trial

    PubMed Central

    Jackson, Louise J; Roberts, Tracy E; Fuller, Sebastian S; Sutcliffe, Lorna J; Saunders, John M; Copas, Andrew J; Mercer, Catherine H; Cassell, Jackie A; Estcourt, Claudia S

    2015-01-01

    Background The objective of this study was to compare the costs and outcomes of two sexually transmitted infection (STI) screening interventions targeted at men in football club settings in England, including screening promoted by team captains. Methods A comparison of costs and outcomes was undertaken alongside a pilot cluster randomised control trial involving three trial arms: (1) captain-led and poster STI screening promotion; (2) sexual health advisor-led and poster STI screening promotion and (3) poster-only STI screening promotion (control/comparator). For all study arms, resource use and cost data were collected prospectively. Results There was considerable variation in uptake rates between clubs, but results were broadly comparable across study arms with 50% of men accepting the screening offer in the captain-led arm, 67% in the sexual health advisor-led arm and 61% in the poster-only control arm. The overall costs associated with the intervention arms were similar. The average cost per player tested was comparable, with the average cost per player tested for the captain-led promotion estimated to be £88.99 compared with £88.33 for the sexual health advisor-led promotion and £81.87 for the poster-only (control) arm. Conclusions Costs and outcomes were similar across intervention arms. The target sample size was not achieved, and we found a greater than anticipated variability between clubs in the acceptability of screening, which limited our ability to estimate acceptability for intervention arms. Further evidence is needed about the public health benefits associated with screening interventions in non-clinical settings so that their cost-effectiveness can be fully evaluated. PMID:25512670

  18. Three dimensional audio versus head down TCAS displays

    NASA Technical Reports Server (NTRS)

    Begault, Durand R.; Pittman, Marc T.

    1994-01-01

    The advantage of a head up auditory display was evaluated in an experiment designed to measure and compare the acquisition time for capturing visual targets under two conditions: Standard head down traffic collision avoidance system (TCAS) display, and three-dimensional (3-D) audio TCAS presentation. Ten commercial airline crews were tested under full mission simulation conditions at the NASA Ames Crew-Vehicle Systems Research Facility Advanced Concepts Flight Simulator. Scenario software generated targets corresponding to aircraft which activated a 3-D aural advisory or a TCAS advisory. Results showed a significant difference in target acquisition time between the two conditions, favoring the 3-D audio TCAS condition by 500 ms.

  19. Affective priming using a color-naming task: a test of an affective-motivational account of affective priming effects.

    PubMed

    Hermans, D; Van den Broeck, A; Eelen, P

    1998-01-01

    The affective priming effect, i.e. shorter response latencies for affectively congruent as compared to affectively incongruent prime-target pairs, is now a well-documented phenomenon. Nevertheless, little is known about the specific processes that underlie the affective priming effect. Several mechanisms have been put forward by different authors, but these theoretical accounts only apply to specific types of tasks (e.g. evaluation lexical decisions) or are rather unparsimonious. Hermans, De Houwer, and Eelen (1996) recently proposed a model of the affective priming effect that is based on the idea of the activation of corresponding or conflicting affective-motivational action tendencies. According to this model, affectively incongruent prime-target pairs should not only lead to relatively longer response latencies on tasks that concern the target word itself (target-specific tasks, e.g. evaluation pronunciation), but also on tasks that are unrelated to the actual identity of the specific target word. This hypothesis was tested in a series of four experiments in which participants had to name the color in which the target word was printed. In spite of procedural variations, results showed that the congruence between the valence of prime and target did not influence the color-naming times. The present results therefore provide no direct support for the affective-motivational account of the affective priming effect. Suggestions for future research are provided.

  20. Dual gated PET/CT imaging of small targets of the heart: method description and testing with a dynamic heart phantom.

    PubMed

    Kokki, Tommi; Sipilä, Hannu T; Teräs, Mika; Noponen, Tommi; Durand-Schaefer, Nicolas; Klén, Riku; Knuuti, Juhani

    2010-01-01

    In PET imaging respiratory and cardiac contraction motions interfere the imaging of heart. The aim was to develop and evaluate dual gating method for improving the detection of small targets of the heart. The method utilizes two independent triggers which are sent periodically into list mode data based on respiratory and ECG cycles. An algorithm for generating dual gated segments from list mode data was developed. The test measurements showed that rotational and axial movements of point source can be separated spatially to different segments with well-defined borders. The effect of dual gating on detection of small moving targets was tested with a moving heart phantom. Dual gated images showed 51% elimination (3.6 mm out of 7.0 mm) of contraction motion of hot spot (diameter 3 mm) and 70% elimination (14 mm out of 20 mm) of respiratory motion. Averaged activity value of hot spot increases by 89% when comparing to non-gated images. Patient study of suspected cardiac sarcoidosis shows sharper spatial myocardial uptake profile and improved detection of small myocardial structures such as papillary muscles. The dual gating method improves detection of small moving targets in a phantom and it is feasible in clinical situations.

  1. Effect of a viscoelastic target on the impact response of a flat-nosed projectile

    NASA Astrophysics Data System (ADS)

    Liu, Hu; Yang, Jialing; Liu, Hua

    2018-02-01

    Taylor impact is a widely used strategy in which a flat-nosed projectile is fired onto a rigid anvil directly to determine the dynamic strength of rod specimens. Nowadays, the rigid anvil is often replaced by an output target bar to ensure the accuracy of measurement via recording strain signals in the output bar. For testing the dynamic strength of low-density materials, a low-impedance target bar, which exhibits viscoelastic characteristics is often employed. In this paper, an extended Taylor model is proposed to improve the idealization of treating the target bar as perfectly rigid material in the classic Taylor model, and the viscoelastic effect of the target bar is incorporated. The viscoelastic target bar is depicted by two elastic springs and one dashpot. Based on the plastic shock wave theory in the flat-nosed projectile associated with the viscoelastic wave analysis in the target bar, the viscoelastic effect of the target bar on the impact response of the flat-nosed projectile is investigated. The finite element simulation is also carried out to verify the theoretical model, and good agreement is found. The present theoretical model is also called the Taylor-cylinder Hopkinson impact, which provides a more accurate way to identify the dynamic material parameters. The dynamic responses of the present model are further compared with previous elastic and rigid target bar models. It is found that the viscoelastic effect of the target bar should be taken into consideration in the Taylor-cylinder Hopkinson impact test for low-impedance materials.

  2. Evaluative priming of naming and semantic categorization responses revisited: a mutual facilitation explanation.

    PubMed

    Schmitz, Melanie; Wentura, Dirk

    2012-07-01

    The evaluative priming effect (i.e., faster target responses following evaluatively congruent compared with evaluatively incongruent primes) in nonevaluative priming tasks (such as naming or semantic categorization tasks) is considered important for the question of how evaluative connotations are represented in memory. However, the empirical evidence is rather ambiguous: Positive effects as well as null results and negatively signed effects have been found. We tested the assumption that different processes are responsible for these results. In particular, we argue that positive effects are due to target-encoding facilitation (caused by a congruent prime), while negative effects are due to prime-activation maintenance (caused by a congruent target) and subsequent response conflict. In 4 experiments, we used a negative prime-target stimulus-onset asynchrony (SOA) to minimize target-encoding facilitation and maximize prime maintenance. In a naming task (Experiment 1), we found a negatively signed evaluative priming effect if prime and target competed for naming responses. In a semantic categorization task (i.e., person vs. animal; Experiments 2 and 3), response conflicts between prime and target were significantly larger in case of evaluative congruence compared with incongruence. These results corroborate the theory that a prime has more potential to interfere with the target response if its activation is maintained by an evaluatively congruent target. Experiment 4a/b indicated valence specificity of the effect. Implications for the memory representation of valence are discussed. 2012 APA, all rights reserved

  3. Evaluation of Altona Diagnostics RealStar Zika Virus Reverse Transcription-PCR Test Kit for Zika Virus PCR Testing

    PubMed Central

    Lombos, Ernesto; Tang, Elaine; Perusini, Stephen; Eshaghi, Alireza; Nagra, Sandeep; Frantz, Christine; Olsha, Romy; Kristjanson, Erik; Dimitrova, Kristina; Safronetz, David; Drebot, Mike

    2017-01-01

    ABSTRACT With the emerging Zika virus (ZIKV) epidemic, accessible real-time reverse transcription-PCR (rRT-PCR) assays are needed to streamline testing. The commercial Altona Diagnostics RealStar ZIKV rRT-PCR test kit (Altona PCR) has been approved for emergency use authorization by the U.S. FDA. Our aim was to verify the Altona PCR by comparing it to the CDC-designed dual-target ZIKV rRT-PCR reference assay (reference PCR) and describe the demographics of patients tested for ZIKV by rRT-PCR in Ontario, Canada. A large set of clinical specimens was tested for ZIKV by the Altona PCR and the reference PCR. Positive or equivocal specimens underwent PCR and Sanger sequencing targeting the ZIKV NS5 gene. A total of 671 serum specimens were tested by the reference PCR: 58 (8.6%) were positive, 193 (28.8%) were equivocal, and 420 (62.6%) were negative. Ninety percent of the reference PCR-positive patients were tested in the first 5 days after symptom onset. The Altona PCR was performed on 284/671 specimens tested by the reference PCR. The Altona PCR was positive for 53/58 (91%) reference PCR-positive specimens and 16/193 (8%) reference PCR-equivocal specimens; the ZIKV NS5 PCR was positive for all 68 Altona PCR-positive specimens and negative for all 181 Altona PCR-negative specimens that underwent the NS5 PCR. The Altona PCR has very good sensitivity (91%) and specificity (97%) compared to the reference PCR. The Altona PCR can be used for ZIKV diagnostic testing and has less extensive verification requirements than a laboratory-developed test. PMID:28298448

  4. Cost effectiveness of targeted high-dose atorvastatin therapy following genotype testing in patients with acute coronary syndrome.

    PubMed

    Parthan, Anju; Leahy, Kevin J; O'Sullivan, Amy K; Iakoubova, Olga A; Bare, Lance A; Devlin, James J; Weinstein, Milton C

    2013-06-01

    Results from the PROVE IT trial suggest that patients with acute coronary syndrome (ACS) treated with atorvastatin 80 mg/day (A80) have significantly lower rates of cardiovascular events compared with patients treated with pravastatin 40 mg/day (P40). In a genetic post hoc substudy of the PROVE IT trial, the rate of event reduction was greater in carriers of the Trp719Arg variant in kinesin family member 6 protein (KIF6) than in noncarriers. We assessed the cost effectiveness of testing for the KIF6 variant followed by targeted statin therapy (KIF6 Testing) versus not testing patients (No Test) and treating them with P40 or A80 in the USA from a payer perspective. A Markov model was developed in which 2-year event rates from PROVE IT were extrapolated over a lifetime horizon. Costs and utilities were derived from published literature. All costs were in 2010 US dollars except the cost of A80, which was in 2012 US dollars because the generic formulation was available in 2012. Expected costs and quality-adjusted life-years (QALYs) were estimated for each strategy over a lifetime horizon. Lifetime costs were US$31,700; US$37,100 and US$41,300 for No Test P40, KIF6 Testing and No Test A80 strategies, respectively. The No Test A80 strategy was associated with more QALYs (9.71) than the KIF6 Testing (9.69) and No Test P40 (9.57) strategies. No Test A80 had an incremental cost-effectiveness ratio (ICER) of US$232,100 per QALY gained compared with KIF6 Testing. KIF6 Testing had an ICER of US$45,300 per QALY compared with No Test P40. Testing ACS patients for KIF6 carrier status may be a cost-effective strategy at commonly accepted thresholds. Treating all patients with A80 is more expensive than treating patients on the basis of KIF6 results, but the modest gain in QALYs is achieved at a cost/QALY that is generally considered unacceptable compared with the KIF6 Testing strategy. Compared with treating all patients with P40, the KIF6 Testing strategy had an ICER below US$50,000 per QALY. The conclusions from this study are sensitive to the price of generic A80 and the effect on adherence of knowing KIF6 carrier status. The results were based on a post hoc substudy of the PROVE IT trial, which was not designed to test the effectiveness of KIF6 testing.

  5. National Geospatial-Intelligence Agency (NGA) Calibration Target Placements during HI-SCALE (Holistic Interactions of Shallow Clouds, Aerosols, and Land-Ecosystems)

    DOE Data Explorer

    Kalukin, Andrew; Endo, Satashi

    2016-08-30

    Test the feasibility of incorporating atmospheric models to improve simulation algorithms of image collection, developed at NGA. Various calibration objects will be used to compare simulated image products with real image products.

  6. Gene Polymorphism Studies in a Teaching Laboratory

    ERIC Educational Resources Information Center

    Shultz, Jeffry

    2009-01-01

    I present a laboratory procedure for illustrating transcription, post-transcriptional modification, gene conservation, and comparative genetics for use in undergraduate biology education. Students are individually assigned genes in a targeted biochemical pathway, for which they design and test polymerase chain reaction (PCR) primers. In this…

  7. Domain Regeneration for Cross-Database Micro-Expression Recognition

    NASA Astrophysics Data System (ADS)

    Zong, Yuan; Zheng, Wenming; Huang, Xiaohua; Shi, Jingang; Cui, Zhen; Zhao, Guoying

    2018-05-01

    In this paper, we investigate the cross-database micro-expression recognition problem, where the training and testing samples are from two different micro-expression databases. Under this setting, the training and testing samples would have different feature distributions and hence the performance of most existing micro-expression recognition methods may decrease greatly. To solve this problem, we propose a simple yet effective method called Target Sample Re-Generator (TSRG) in this paper. By using TSRG, we are able to re-generate the samples from target micro-expression database and the re-generated target samples would share same or similar feature distributions with the original source samples. For this reason, we can then use the classifier learned based on the labeled source samples to accurately predict the micro-expression categories of the unlabeled target samples. To evaluate the performance of the proposed TSRG method, extensive cross-database micro-expression recognition experiments designed based on SMIC and CASME II databases are conducted. Compared with recent state-of-the-art cross-database emotion recognition methods, the proposed TSRG achieves more promising results.

  8. Transiting Exoplanet Studies and Community Targets for JWST's Early Release Science Program

    NASA Technical Reports Server (NTRS)

    Stevenson, Kevin B.; Lewis, Nikole K.; Bean, Jacob L.; Beichman, Charles A.; Fraine, Jonathan; Kilpatrick, Brian M.; Krick, J. E.; Lothringer, Joshua D.; Mandell, Avi M.; Valenti, Jeff A.; hide

    2016-01-01

    The James Webb Space Telescope (JWST) will likely revolutionize transiting exoplanet atmospheric science, due to a combination of its capability for continuous, long duration observations and its larger collecting area, spectral coverage, and spectral resolution compared to existing space-based facilities. However, it is unclear precisely how well JWST will perform and which of its myriad instruments and observing modes will be best suited for transiting exoplanet studies. In this article, we describe a prefatory JWST Early Release Science (ERS) Cycle 1 program that focuses on testing specific observing modes to quickly give the community the data and experience it needs to plan more efficient and successful transiting exoplanet characterization programs in later cycles. We propose a multi-pronged approach wherein one aspect of the program focuses on observing transits of a single target with all of the recommended observing modes to identify and understand potential systematics, compare transmission spectra at overlapping and neighboring wavelength regions, confirm throughputs, and determine overall performances. In our search for transiting exoplanets that are well suited to achieving these goals, we identify 12 objects (dubbed community targets'') that meet our defined criteria. Currently, the most favorable target is WASP-62b because of its large predicted signal size, relatively bright host star, and location in JWST's continuous viewing zone. Since most of the community targets do not have well-characterized atmospheres, we recommend initiating preparatory observing programs to determine the presence of obscuring clouds/hazes within their atmospheres. Measurable spectroscopic features are needed to establish the optimal resolution and wavelength regions for exoplanet characterization. Other initiatives from our proposed ERS program include testing the instrument brightness limits and performing phase-curve observations. The latter are a unique challenge compared to transit observations because of their significantly longer durations. Using only a single mode, we propose to observe a full-orbit phase curve of one of the previously characterized, short-orbital-period planets to evaluate the facility-level aspects of long, uninterrupted time-series observations.

  9. Transiting Exoplanet Studies and Community Targets for JWST's Early Release Science Program

    NASA Technical Reports Server (NTRS)

    Stevenson, Kevin B.; Lewis, Nikole K.; Bean, Jacob L.; Beichman, Charles; Fraine, Jonathan; Kilpatrick, Brian M.; Krick, J. E.; Lothringer, Joshua D.; Mandell, Avi M.; Valenti, Jeff A.; hide

    2016-01-01

    The James Webb Space Telescope (JWST) will likely revolutionize transiting exoplanet atmospheric science, due to a combination of its capability for continuous, long duration observations and its larger collecting area, spectral coverage, and spectral resolution compared to existing space-based facilities. However, it is unclear precisely how well JWST will perform and which of its myriad instruments and observing modes will be best suited for transiting exoplanet studies. In this article, we describe a prefatory JWST Early Release Science (ERS) Cycle1 program that focuses on testing specific observing modes to quickly give the community the data and experience it needs to plan more efficient and successful transiting exoplanet characterization programs in later cycles. We propose a multi-pronged approach wherein one aspect of the program focuses on observing transits of a single target with all of the recommended observing modes to identify and understand potential systematics, compare transmission spectra at overlapping and neighboring wavelength regions, confirm throughputs, and determine overall performances. In our search for transiting exoplanets that are well suited to achieving these goals, we identify 12 objects (dubbed community targets) that meet our defined criteria. Currently, the most favorable target is WASP-62b because of its large predicted signal size, relatively bright host star, and location in JWSTs continuous viewing zone. Since most of the community targets do not have well-characterized atmospheres, we recommend initiating preparatory observing programs to determine the presence of obscuring cloudshazes within their atmospheres. Measurable spectroscopic features are needed to establish the optimal resolution and wavelength regions for exoplanet characterization. Other initiatives from our proposed ERS program include testing the instrument brightness limits and performing phase-curve observations. The latter are a unique challenge compared to transit observations because of their significantly longer durations. Using only a single mode, we propose to observe a full-orbit phase curve of one of the previously characterized, short-orbital-period planets to evaluate the facility-level aspects of long, uninterrupted time-series observations.

  10. Comparison of diagnostic techniques for the detection of Cryptosporidium oocysts in animal samples

    PubMed Central

    Mirhashemi, Marzieh Ezzaty; Zintl, Annetta; Grant, Tim; Lucy, Frances E.; Mulcahy, Grace; De Waal, Theo

    2015-01-01

    While a large number of laboratory methods for the detection of Cryptosporidium oocysts in faecal samples are now available, their efficacy for identifying asymptomatic cases of cryptosporidiosis is poorly understood. This study was carried out to determine a reliable screening test for epidemiological studies in livestock. In addition, three molecular tests were compared to identify Cryptosporidium species responsible for the infection in cattle, sheep and horses. A variety of diagnostic tests including microscopic (Kinyoun's staining), immunological (Direct Fluorescence Antibody tests or DFAT), enzyme-linked immunosorbent assay (ELISA), and molecular methods (nested PCR) were compared to assess their ability to detect Cryptosporidium in cattle, horse and sheep faecal samples. The results indicate that the sensitivity and specificity of each test is highly dependent on the input samples; while Kinyoun's and DFAT proved to be reliable screening tools for cattle samples, DFAT and PCR analysis (targeted at the 18S rRNA gene fragment) were more sensitive for screening sheep and horse samples. Finally different PCR primer sets targeted at the same region resulted in the preferential amplification of certain Cryptosporidium species when multiple species were present in the sample. Therefore, for identification of Cryptosporidium spp. in the event of asymptomatic cryptosporidiosis, the combination of different 18S rRNA nested PCR primer sets is recommended for further epidemiological applications and also tracking the sources of infection. PMID:25662435

  11. Rifaximin: The Revolutionary Antibiotic Approach for Irritable Bowel Syndrome.

    PubMed

    Triantafyllou, Konstantinos; Sioulas, Athanasios D; Giamarellos-Bourboulis, Evangelos J

    2015-01-01

    A large number of clinical studies using breath testing and a smaller number of studies using quantitative cultures of the upper small intestine established a link between irritable bowel syndrome (IBS) and small intestinal bacterial overgrowth (SIBO). A series of 12 studies both prospective and retrospective in design in a population of patients with SIBO without IBS showed that the non-absorbable antibiotic rifaximin can eradicate SIBO as proved through decrease of the exhaled hydrogen and methane in breath tests. The efficacy of rifaximin was superior over the comparator treatment in most of these studies. Based on these findings, short course rifaximin was tested in various concentrations in eight open-label trials in patients with IBS and proven SIBO by breath test. Similar efficacy of rifaximin was shown in SIBO eradication; this was accompanied by improvement of the global score for IBS symptoms. Finally, five double-blind randomized clinical trials were conducted in patients with IBS; four were placebo-controlled. The larger trials were TARGET 1 and TARGET 2 studies testing rifaximin at a regimen of 550 mg tid for 14 days. All trials showed a significant superiority of rifaximin over comparator for the improvement of global symptoms of IBS and bloating. Although the aforementioned results render rifaximin a revolutionary therapeutic approach for IBS, several concerns on induction of antimicrobial resistant flora remain.

  12. Measurement of total ultrasonic power using thermal expansion and change in buoyancy of an absorbing target

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dubey, P. K., E-mail: premkdubey@gmail.com; Kumar, Yudhisther; Gupta, Reeta

    2014-05-15

    The Radiation Force Balance (RFB) technique is well established and most widely used for the measurement of total ultrasonic power radiated by ultrasonic transducer. The technique is used as a primary standard for calibration of ultrasonic transducers with relatively fair uncertainty in the low power (below 1 W) regime. In this technique, uncertainty comparatively increases in the range of few watts wherein the effects such as thermal heating of the target, cavitations, and acoustic streaming dominate. In addition, error in the measurement of ultrasonic power is also caused due to movement of absorber at relatively high radiated force which occursmore » at high power level. In this article a new technique is proposed which does not measure the balance output during transducer energized state as done in RFB. It utilizes the change in buoyancy of the absorbing target due to local thermal heating. The linear thermal expansion of the target changes the apparent mass in water due to buoyancy change. This forms the basis for the measurement of ultrasonic power particularly in watts range. The proposed method comparatively reduces uncertainty caused by various ultrasonic effects that occur at high power such as overshoot due to momentum of target at higher radiated force. The functionality of the technique has been tested and compared with the existing internationally recommended RFB technique.« less

  13. Measurement of total ultrasonic power using thermal expansion and change in buoyancy of an absorbing target

    NASA Astrophysics Data System (ADS)

    Dubey, P. K.; Kumar, Yudhisther; Gupta, Reeta; Jain, Anshul; Gohiya, Chandrashekhar

    2014-05-01

    The Radiation Force Balance (RFB) technique is well established and most widely used for the measurement of total ultrasonic power radiated by ultrasonic transducer. The technique is used as a primary standard for calibration of ultrasonic transducers with relatively fair uncertainty in the low power (below 1 W) regime. In this technique, uncertainty comparatively increases in the range of few watts wherein the effects such as thermal heating of the target, cavitations, and acoustic streaming dominate. In addition, error in the measurement of ultrasonic power is also caused due to movement of absorber at relatively high radiated force which occurs at high power level. In this article a new technique is proposed which does not measure the balance output during transducer energized state as done in RFB. It utilizes the change in buoyancy of the absorbing target due to local thermal heating. The linear thermal expansion of the target changes the apparent mass in water due to buoyancy change. This forms the basis for the measurement of ultrasonic power particularly in watts range. The proposed method comparatively reduces uncertainty caused by various ultrasonic effects that occur at high power such as overshoot due to momentum of target at higher radiated force. The functionality of the technique has been tested and compared with the existing internationally recommended RFB technique.

  14. Pneumococcal vaccine targeting strategy for older adults: customized risk profiling.

    PubMed

    Balicer, Ran D; Cohen, Chandra J; Leibowitz, Morton; Feldman, Becca S; Brufman, Ilan; Roberts, Craig; Hoshen, Moshe

    2014-02-12

    Current pneumococcal vaccine campaigns take a broad, primarily age-based approach to immunization targeting, overlooking many clinical and administrative considerations necessary in disease prevention and resource planning for specific patient populations. We aim to demonstrate the utility of a population-specific predictive model for hospital-treated pneumonia to direct effective vaccine targeting. Data was extracted for 1,053,435 members of an Israeli HMO, age 50 and older, during the study period 2008-2010. We developed and validated a logistic regression model to predict hospital-treated pneumonia using training and test samples, including a set of standard and population-specific risk factors. The model's predictive value was tested for prospectively identifying cases of pneumonia and invasive pneumococcal disease (IPD), and was compared to the existing international paradigm for patient immunization targeting. In a multivariate regression, age, co-morbidity burden and previous pneumonia events were most strongly positively associated with hospital-treated pneumonia. The model predicting hospital-treated pneumonia yielded a c-statistic of 0.80. Utilizing the predictive model, the top 17% highest-risk within the study validation population were targeted to detect 54% of those members who were subsequently treated for hospitalized pneumonia in the follow up period. The high-risk population identified through this model included 46% of the follow-up year's IPD cases, and 27% of community-treated pneumonia cases. These outcomes were compared with international guidelines for risk for pneumococcal diseases that accurately identified only 35% of hospitalized pneumonia, 41% of IPD cases and 21% of community-treated pneumonia. We demonstrate that a customized model for vaccine targeting performs better than international guidelines, and therefore, risk modeling may allow for more precise vaccine targeting and resource allocation than current national and international guidelines. Health care managers and policy-makers may consider the strategic potential of utilizing clinical and administrative databases for creating population-specific risk prediction models to inform vaccination campaigns. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. High-Value, Cost-Conscious Care: Iterative Systems-Based Interventions to Reduce Unnecessary Laboratory Testing.

    PubMed

    Sadowski, Brett W; Lane, Alison B; Wood, Shannon M; Robinson, Sara L; Kim, Chin Hee

    2017-09-01

    Inappropriate testing contributes to soaring healthcare costs within the United States, and teaching hospitals are vulnerable to providing care largely for academic development. Via its "Choosing Wisely" campaign, the American Board of Internal Medicine recommends avoiding repetitive testing for stable inpatients. We designed systems-based interventions to reduce laboratory orders for patients admitted to the wards at an academic facility. We identified the computer-based order entry system as an appropriate target for sustainable intervention. The admission order set had allowed multiple routine tests to be ordered repetitively each day. Our iterative study included interventions on the automated order set and cost displays at order entry. The primary outcome was number of routine tests controlled for inpatient days compared with the preceding year. Secondary outcomes included cost savings, delays in care, and adverse events. Data were collected over a 2-month period following interventions in sequential years and compared with the year prior. The first intervention led to 0.97 fewer laboratory tests per inpatient day (19.4%). The second intervention led to sustained reduction, although by less of a margin than order set modifications alone (15.3%). When extrapolating the results utilizing fees from the Centers for Medicare and Medicaid Services, there was a cost savings of $290,000 over 2 years. Qualitative survey data did not suggest an increase in care delays or near-miss events. This series of interventions targeting unnecessary testing demonstrated a sustained reduction in the number of routine tests ordered, without adverse effects on clinical care. Published by Elsevier Inc.

  16. The serial nature of the masked onset priming effect revisited.

    PubMed

    Mousikou, Petroula; Coltheart, Max

    2014-01-01

    Reading aloud is faster when target words/nonwords are preceded by masked prime words/nonwords that share their first sound with the target (e.g., save-SINK) compared to when primes and targets are unrelated to each other (e.g., farm-SINK). This empirical phenomenon is the masked onset priming effect (MOPE) and is known to be due to serial left-to-right processing of the prime by a sublexical reading mechanism. However, the literature in this domain lacks a critical experiment. It is possible that when primes are real words their orthographic/phonological representations are activated in parallel and holistically during prime presentation, so any phoneme overlap between primes and targets (and not just initial-phoneme overlap) could facilitate target reading aloud. This is the prediction made by the only computational models of reading aloud that are able to simulate the MOPE, namely the DRC1.2.1, CDP+, and CDP++ models. We tested this prediction in the present study and found that initial-phoneme overlap (blip-BEST), but not end-phoneme overlap (flat-BEST), facilitated target reading aloud compared to no phoneme overlap (junk-BEST). These results provide support for a reading mechanism that operates serially and from left to right, yet are inconsistent with all existing computational models of single-word reading aloud.

  17. A triplex ribozyme expression system based on a single hairpin ribozyme.

    PubMed

    Aquino-Jarquin, Guillermo; Benítez-Hess, María Luisa; DiPaolo, Joseph A; Alvarez-Salas, Luis M

    2008-09-01

    Triplex ribozyme (RZ) configurations allow for the individual activity of trans-acting RZs in multiple expression cassettes (multiplex), thereby increasing target cleavage relative to conventionally expressed RZs. Although hairpin RZs have been advantageously compared to hammerhead RZs, their longer size and structural features complicated triplex design. We present a triplex expression system based on a single hairpin RZ with transcleavage capability and simple engineering. The system was tested in vitro using cis- and trans-cleavage kinetic assays against a known target RNA from HPV-16 E6/E7 mRNA. Single and multiplex triplex RZ constructs were more efficient in cleaving the target than tandem-cloned hairpin RZs, suggesting that the release of individual RZs enhanced trans-cleavage kinetics. Multiplex systems constructed with two different hairpin RZs resulted in better trans-cleavage compared to standard double-RZ constructs. In addition, the triplex RZ performed cis- and trans-cleavage in cervical cancer cells. The use of triplex configurations with multiplex RZs permit differential targeting of the same or different RNA, thus improving potential use against unstable targets. This prototype will provide the basis for the development of future RZ-based therapies and technologies.

  18. Neutral Beam Source and Target Plasma for Development of a Local Electric Field Fluctuation Diagnostic

    NASA Astrophysics Data System (ADS)

    Bakken, M. R.; Burke, M. G.; Fonck, R. J.; Lewicki, B. T.; Rhodes, A. T.; Winz, G. R.

    2016-10-01

    A new diagnostic measuring local E-> (r , t) fluctuations is being developed for plasma turbulence studies in tokamaks. This is accomplished by measuring fluctuations in the separation of the π components in the Hα motional Stark spectrum. Fluctuations in this separation are expected to be Ẽ / ẼEMSE 10-3EMSE 10-3 . In addition to a high throughput, high speed spectrometer, the project requires a low divergence (Ω 0 .5°) , 80 keV, 2.5 A H0 beam and a target plasma test stand. The beam employs a washer-stack arc ion source to achieve a high species fraction at full energy. Laboratory tests of the ion source demonstrate repeatable plasmas with Te 10 eV and ne 1.6 ×1017 m-3, sufficient for the beam ion optics requirements. Te and ne scalings of the ion source plasma are presented with respect to operational parameters. A novel three-phase resonant converter power supply will provide 6 mA/cm2 of 80 keV H0 at the focal plane for pulse lengths up to 15 ms, with low ripple δV / 80 keV 0.05 % at 280 kHz. Diagnostic development and validation tests will be performed on a magnetized plasma test stand with 0.5 T field. The test chamber will utilize a washer-stack arc source to produce a target plasma comparable to edge tokamak plasmas. A bias-plate with programmable power supply will be used to impose Ẽ within the target plasma. Work supported by US DOE Grant DE-FG02-89ER53296.

  19. Safety diagnosis: are we doing a good job?

    PubMed

    Park, Peter Y; Sahaji, Rajib

    2013-03-01

    Collision diagnosis is the second step in the six-step road safety management process described in the AASHTO Highway Safety Manual (HSM). Diagnosis is designed to identify a dominant or abnormally high proportion of particular collision configurations (e.g., rear end, right angle, etc.) at a target location. The primary diagnosis method suggested in the HSM is descriptive data analysis. This type of analysis relies on, for example, pie charts, histograms, and/or collision diagrams. Using location specific collision data (e.g., collision frequency per collision configuration for a target location), safety engineers identify (the most) frequent collision configurations. Safety countermeasures are then likely to concentrate on preventing the selected collision configurations. Although its real-world application in engineering practice is limited, an additional collision diagnosis method, known as the beta-binomial (BB) test, is also presented as the secondary diagnosis tool in the HSM. The BB test compares the proportion of a particular collision configuration observed at one location with the proportion of the same collision configuration found at other reference locations which are similar to the target location in terms of selected traffic and roadway characteristics (e.g., traffic volume, traffic control, and number of lanes). This study compared the outcomes obtained from descriptive data analysis and the BB test, and investigates two questions: (1) Do descriptive data analysis and the BB tests produce the same results (i.e., do they select the same collision configurations at the same locations)? and (2) If the tests produce different results, which result should be adopted in engineering practice? This study's analysis was based on a sample of the most recent five years (2005-2009) of collision and roadway configuration data for 143 signalized intersections in the City of Saskatoon, Saskatchewan. The study results show that the BB test's role in diagnosing safety concerns in road safety engineering projects such as safety review projects for existing roadways may be just as important as the descriptive data analysis method. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Experimental studies of the effect target geometry on the evolution of laser produced plasma plumes

    NASA Astrophysics Data System (ADS)

    Beatty, Cuyler; Anderson, Austin; Iratcabal, Jeremy; Dutra, Eric; Covington, Aaron

    2016-10-01

    The expansion of the laser plumes was shown to be dependent on the initial target geometry. A 16 channel framing camera was used to record the plume shape and propagation speeds were determined from analysis of the images. Plastic targets were manufactured using different methods including 3D printing, CNC machining and vacuum casting. Preliminary target designs were made using a 3D printer and ABS plastic material. These targets were then tested using a 3 J laser with a 5 ns duration pulse. Targets with a deep conical depression were shown to produce highly collimated plumes when compared to flat top targets. Preliminary results of these experiments will be discussed along with planned future experiments that will use the indented targets with a 30 J laser with a 0.8 ns duration pulse in preparation for pinched laser plume experiments at the Nevada Terawatt Facility. Other polymers that are readily available in a deuterated form will also be explored as part of an effort to develop a cost effective plasma plume target for follow on neutron production experiments. Dr. Austin Anderson.

  1. Attentional priorities and access to short-term memory: parietal interactions.

    PubMed

    Gillebert, Céline R; Dyrholm, Mads; Vangkilde, Signe; Kyllingsbæk, Søren; Peeters, Ronald; Vandenberghe, Rik

    2012-09-01

    The intraparietal sulcus (IPS) has been implicated in selective attention as well as visual short-term memory (VSTM). To contrast mechanisms of target selection, distracter filtering, and access to VSTM, we combined behavioral testing, computational modeling and functional magnetic resonance imaging. Sixteen healthy subjects participated in a change detection task in which we manipulated both target and distracter set sizes. We directly compared the IPS response as a function of the number of targets and distracters in the display and in VSTM. When distracters were not present, the posterior and middle segments of IPS showed the predicted asymptotic activity increase with an increasing target set size. When distracters were added to a single target, activity also increased as predicted. However, the addition of distracters to multiple targets suppressed both middle and posterior IPS activities, thereby displaying a significant interaction between the two factors. The interaction between target and distracter set size in IPS could not be accounted for by a simple explanation in terms of number of items accessing VSTM. Instead, it led us to a model where items accessing VSTM receive differential weights depending on their behavioral relevance, and secondly, a suppressive effect originates during the selection phase when multiple targets and multiple distracters are simultaneously present. The reverse interaction between target and distracter set size was significant in the right temporoparietal junction (TPJ), where activity was highest for a single target compared to any other condition. Our study reconciles the role of middle IPS in attentional selection and biased competition with its role in VSTM access. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. A Methodology to Compare Insulin Dosing Recommendations in Real-Life Settings.

    PubMed

    Groat, Danielle; Grando, Maria A; Thompson, Bithika; Neto, Pedro; Soni, Hiral; Boyle, Mary E; Bailey, Marilyn; Cook, Curtiss B

    2017-11-01

    We propose a methodology to analyze complex real-life glucose data in insulin pump users. Patients with type 1 diabetes (T1D) on insulin pumps were recruited from an academic endocrinology practice. Glucose data, insulin bolus (IB) amounts, and self-reported alcohol consumption and exercise events were collected for 30 days. Rules were developed to retrospectively compare IB recommendations from the insulin pump bolus calculator (IPBC) against recommendations from a proposed decision aid (PDA) and for assessing the PDA's recommendation for exercise and alcohol. Data from 15 participants were analyzed. When considering instances where glucose was below target, the PDA recommended a smaller dose in 14%, but a larger dose in 13% and an equivalent IB in 73%. For glucose levels at target, the PDA suggested an equivalent IB in 58% compared to the subject's IPBC, but higher doses in 20% and lower in 22%. In events where postprandial glucose was higher than target, the PDA suggested higher doses in 25%, lower doses in 13%, and equivalent doses in 62%. In 64% of all alcohol events the PDA would have provided appropriate advice. In 75% of exercise events, the PDA appropriately advised an IB, a carbohydrate snack, or neither. This study provides a methodology to systematically analyze real-life data generated by insulin pumps and allowed a preliminary analysis of the performance of the PDA for insulin dosing. Further testing of the methodological approach in a broader diabetes population and prospective testing of the PDA are needed.

  3. What's in a mask? Information masking with forward and backward visual masks.

    PubMed

    Davis, Chris; Kim, Jeesun

    2011-10-01

    Three experiments tested how the physical format and information content of forward and backward masks affected the extent of visual pattern masking. This involved using different types of forward and backward masks with target discrimination measured by percentage correct in the first experiment (with a fixed target duration) and by an adaptive threshold procedure in the last two. The rationale behind the manipulation of the content of the masks stemmed from masking theories emphasizing attentional and/or conceptual factors rather than visual ones. Experiment 1 used word masks and showed that masking was reduced (a masking reduction effect) when the forward and backward masks were the same word (although in different case) compared to when the masks were different words. Experiment 2 tested the extent to which a reduction in masking might occur due to the physical similarity between the forward and backward masks by comparing the effect of the same content of the masks in the same versus different case. The result showed a significant reduction in masking for same content masks but no significant effect of case. The last experiment examined whether the reduction in masking effect would be observed with nonword masks--that is, having no high-level representation. No reduction in masking was found from same compared to different nonword masks (Experiment 3). These results support the view that the conscious perception of a rapidly displayed target stimulus is in part determined by high-level perceptual/cognitive factors concerned with masking stimulus grouping and attention.

  4. The assessment of commitment: advantages of a unidimensional, target-free approach.

    PubMed

    Klein, Howard J; Cooper, Joseph T; Molloy, Janice C; Swanson, Jacqueline A

    2014-03-01

    This study presents a new approach to assessing commitment reflecting the Klein, Molloy, and Brinsfield (2012) reconceptualization. Klein et al. recast the construct to address issues hindering commitment scholarship, but their claims cannot be tested with existing measures. This paper presents a 4-item measure consistent with the Klein et al. conceptual definition, a measure intended to be unidimensional and applicable across all workplace targets. Our purpose is to present the development of and provide initial validity evidence for this new commitment measure and to compare it to existing alternative measures. Hypotheses around these objectives were tested with data gathered across 5 samples yielding 2,487 participants representing a wide range of jobs, organizations, and industries. Each sample examined a unique set of variables and targets that together provide a comprehensive test of this new measure relative to 8 different targets, several constructs within the nomological network, and 4 prior commitment measures. Results support our hypotheses regarding (a) the measure's properties and structure, (b) convergence and divergence with prior measures of commitment and other constructs in the nomological network, and (c) advantages over prior measures. These findings support the validity of this new approach to assessing commitment, laying the foundation for future research to address critiques of the commitment construct; better examine the multiple commitments individuals simultaneously hold; and bring consistency, synergy, and integration to commitment scholarship across workplace targets. The conceptual, methodological, and practical benefits of the measure are discussed, along with study limitations and future research opportunities.

  5. Identification of Optimal Epitopes for Plasmodium falciparum Rapid Diagnostic Tests That Target Histidine-Rich Proteins 2 and 3

    PubMed Central

    Lee, Nelson; Gatton, Michelle L.; Pelecanos, Anita; Bubb, Martin; Gonzalez, Iveth; Bell, David; Cheng, Qin

    2012-01-01

    Rapid diagnostic tests (RDTs) represent important tools to diagnose malaria infection. To improve understanding of the variable performance of RDTs that detect the major target in Plasmodium falciparum, namely, histidine-rich protein 2 (HRP2), and to inform the design of better tests, we undertook detailed mapping of the epitopes recognized by eight HRP-specific monoclonal antibodies (MAbs). To investigate the geographic skewing of this polymorphic protein, we analyzed the distribution of these epitopes in parasites from geographically diverse areas. To identify an ideal amino acid motif for a MAb to target in HRP2 and in the related protein HRP3, we used a purpose-designed script to perform bioinformatic analysis of 448 distinct gene sequences from pfhrp2 and from 99 sequences from the closely related gene pfhrp3. The frequency and distribution of these motifs were also compared to the MAb epitopes. Heat stability testing of MAbs immobilized on nitrocellulose membranes was also performed. Results of these experiments enabled the identification of MAbs with the most desirable characteristics for inclusion in RDTs, including copy number and coverage of target epitopes, geographic skewing, heat stability, and match with the most abundant amino acid motifs identified. This study therefore informs the selection of MAbs to include in malaria RDTs as well as in the generation of improved MAbs that should improve the performance of HRP-detecting malaria RDTs. PMID:22259210

  6. Investigation of Liner Characteristics in the NASA Langley Curved Duct Test Rig

    NASA Technical Reports Server (NTRS)

    Gerhold, Carl H.; Brown, Martha C.; Watson, Willie R.; Jones, Michael G.

    2007-01-01

    The Curved Duct Test Rig (CDTR), which is designed to investigate propagation of sound in a duct with flow, has been developed at NASA Langley Research Center. The duct incorporates an adaptive control system to generate a tone in the duct at a specific frequency with a target Sound Pressure Level and a target mode shape. The size of the duct, the ability to isolate higher order modes, and the ability to modify the duct configuration make this rig unique among experimental duct acoustics facilities. An experiment is described in which the facility performance is evaluated by measuring the sound attenuation by a sample duct liner. The liner sample comprises one wall of the liner test section. Sound in tones from 500 to 2400 Hz, with modes that are parallel to the liner surface of order 0 to 5, and that are normal to the liner surface of order 0 to 2, can be generated incident on the liner test section. Tests are performed in which sound is generated without axial flow in the duct and with flow at a Mach number of 0.275. The attenuation of the liner is determined by comparing the sound power in a hard wall section downstream of the liner test section to the sound power in a hard wall section upstream of the liner test section. These experimentally determined attenuations are compared to numerically determined attenuations calculated by means of a finite element analysis code. The code incorporates liner impedance values educed from measured data from the NASA Langley Grazing Incidence Tube, a test rig that is used for investigating liner performance with flow and with (0,0) mode incident grazing. The analytical and experimental results compare favorably, indicating the validity of the finite element method and demonstrating that finite element prediction tools can be used together with experiment to characterize the liner attenuation.

  7. A comparison of UV cross-linking and vacuum baking for nucleic acid immobilization and retention

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nierzwicki-Bauer, S.A.; Gebhardt, J.S.; Linkkila, L.

    The effectiveness of UV cross-linking and in vacuo baking for the immobilization and retention of DNA to various solid supports was investigated. Optimal immobilization treatments for supported and unsupported nitrocellulose and nylon membranes were: UV cross-linking at 254 nm with an exposure of 120 milliJoules/cm{sup 2}, or baking in vacuo for two hours at 80{degrees}C. UV-immobilized nitrocellulose-based membranes showed no increase in sensitivity when compared to baked membranes. An increase in sensitivity was observed for UV-immobilized nylon membranes as compared with baked nylon membranes in some instances, although this varied within lots of the membranes tested. Repeated strippings and heterologousmore » reprobings resulted in loss of target DNA from UV-immobilized nylon membranes as compared to baked nylon membranes. Loss of target DNA from UV-immobilized nitrocellulose-based membranes due to repeated strippings and reprobings was even more pronounced. In vacuo baking of supported and unsupported nitrocellulose and nylon membranes was more effective for immobilization, and more importantly, for retention of target DNA through many reprobings of the same blot.« less

  8. Targeted drug delivery nanosystems based on copolymer poly(lactide)-tocopheryl polyethylene glycol succinate for cancer treatment

    NASA Astrophysics Data System (ADS)

    Thu Ha, Phuong; Nguyen, Hoai Nam; Doan Do, Hai; Thong Phan, Quoc; Nguyet Tran Thi, Minh; Phuc Nguyen, Xuan; Nhung Hoang Thi, My; Huong Le, Mai; Nguyen, Linh Toan; Quang Bui, Thuc; Hieu Phan, Van

    2016-03-01

    Along with the development of nanotechnology, drug delivery nanosystems (DDNSs) have attracted a great deal of concern among scientists over the world, especially in cancer treatment. DDNSs not only improve water solubility of anticancer drugs but also increase therapeutic efficacy and minimize the side effects of treatment methods through targeting mechanisms including passive and active targeting. Passive targeting is based on the nano-size of drug delivery systems while active targeting is based on the specific bindings between targeting ligands attached on the drug delivery systems and the unique receptors on the cancer cell surface. In this article we present some of our results in the synthesis and testing of DDNSs prepared from copolymer poly(lactide)-tocopheryl polyethylene glycol succinate (PLA-TPGS), which carry anticancer drugs including curcumin, paclitaxel and doxorubicin. In order to increase the targeting effect to cancer cells, active targeting ligand folate was attached to the DDNSs. The results showed copolymer PLA-TPGS to be an excellent carrier for loading hydrophobic drugs (curcumin and paclitaxel). The fabricated DDNSs had a very small size (50-100 nm) and enhanced the cellular uptake and cytotoxicity of drugs. Most notably, folate-decorated paclitaxel-loaded copolymer PLA-TPGS nanoparticles (Fol/PTX/PLA-TPGS NPs) were tested on tumor-bearing nude mice. During the treatment time, Fol/PTX/PLA-TPGS NPs always exhibited the best tumor growth inhibition compared to free paclitaxel and paclitaxel-loaded copolymer PLA-TPGS nanoparticles. All results evidenced the promising potential of copolymer PLA-TPGS in fabricating targeted DDNSs for cancer treatment.

  9. Modeling guidance and recognition in categorical search: bridging human and computer object detection.

    PubMed

    Zelinsky, Gregory J; Peng, Yifan; Berg, Alexander C; Samaras, Dimitris

    2013-10-08

    Search is commonly described as a repeating cycle of guidance to target-like objects, followed by the recognition of these objects as targets or distractors. Are these indeed separate processes using different visual features? We addressed this question by comparing observer behavior to that of support vector machine (SVM) models trained on guidance and recognition tasks. Observers searched for a categorically defined teddy bear target in four-object arrays. Target-absent trials consisted of random category distractors rated in their visual similarity to teddy bears. Guidance, quantified as first-fixated objects during search, was strongest for targets, followed by target-similar, medium-similarity, and target-dissimilar distractors. False positive errors to first-fixated distractors also decreased with increasing dissimilarity to the target category. To model guidance, nine teddy bear detectors, using features ranging in biological plausibility, were trained on unblurred bears then tested on blurred versions of the same objects appearing in each search display. Guidance estimates were based on target probabilities obtained from these detectors. To model recognition, nine bear/nonbear classifiers, trained and tested on unblurred objects, were used to classify the object that would be fixated first (based on the detector estimates) as a teddy bear or a distractor. Patterns of categorical guidance and recognition accuracy were modeled almost perfectly by an HMAX model in combination with a color histogram feature. We conclude that guidance and recognition in the context of search are not separate processes mediated by different features, and that what the literature knows as guidance is really recognition performed on blurred objects viewed in the visual periphery.

  10. Modeling guidance and recognition in categorical search: Bridging human and computer object detection

    PubMed Central

    Zelinsky, Gregory J.; Peng, Yifan; Berg, Alexander C.; Samaras, Dimitris

    2013-01-01

    Search is commonly described as a repeating cycle of guidance to target-like objects, followed by the recognition of these objects as targets or distractors. Are these indeed separate processes using different visual features? We addressed this question by comparing observer behavior to that of support vector machine (SVM) models trained on guidance and recognition tasks. Observers searched for a categorically defined teddy bear target in four-object arrays. Target-absent trials consisted of random category distractors rated in their visual similarity to teddy bears. Guidance, quantified as first-fixated objects during search, was strongest for targets, followed by target-similar, medium-similarity, and target-dissimilar distractors. False positive errors to first-fixated distractors also decreased with increasing dissimilarity to the target category. To model guidance, nine teddy bear detectors, using features ranging in biological plausibility, were trained on unblurred bears then tested on blurred versions of the same objects appearing in each search display. Guidance estimates were based on target probabilities obtained from these detectors. To model recognition, nine bear/nonbear classifiers, trained and tested on unblurred objects, were used to classify the object that would be fixated first (based on the detector estimates) as a teddy bear or a distractor. Patterns of categorical guidance and recognition accuracy were modeled almost perfectly by an HMAX model in combination with a color histogram feature. We conclude that guidance and recognition in the context of search are not separate processes mediated by different features, and that what the literature knows as guidance is really recognition performed on blurred objects viewed in the visual periphery. PMID:24105460

  11. Electrospin-coating of nitrocellulose membrane enhances sensitivity in nucleic acid-based lateral flow assay.

    PubMed

    Yew, Chee-Hong Takahiro; Azari, Pedram; Choi, Jane Ru; Li, Fei; Pingguan-Murphy, Belinda

    2018-06-07

    Point-of-care biosensors are important tools developed to aid medical diagnosis and testing, food safety and environmental monitoring. Paper-based biosensors, especially nucleic acid-based lateral flow assays (LFA), are affordable, simple to produce and easy to use in remote settings. However, the sensitivity of such assays to infectious diseases has always been a restrictive challenge. Here, we have successfully electrospun polycaprolactone (PCL) on nitrocellulose (NC) membrane to form a hydrophobic coating to reduce the flow rate and increase the interaction rate between the targets and gold nanoparticles-detecting probes conjugates, resulting in the binding of more complexes to the capture probes. With this approach, the sensitivity of the PCL electrospin-coated test strip has been increased by approximately ten-fold as compared to the unmodified test strip. As a proof of concept, this approach holds great potential for sensitive detection of targets at point-of-care testing. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, C; Yin, Y

    Purpose: To compare the dosimetric difference of the target volume and organs at risk(OARs) between conventional intensity-modulated radiotherapy(C-IMRT) and knowledge-based radiation therapy (KBRT) plans for cervix cancer. Methods: 39 patients with cervical cancer after surgery were randomly selected, 20 patient plans were used to create the model, the other 19 cases used for comparative evaluation. All plans were designed in Eclipse system. The prescription dose was 30.6Gy, 17 fractions, OARs dose satisfied to the clinical requirement. A paired t test was used to evaluate the differences of dose-volume histograms (DVH). Results: Comparaed to C-IMRT plan, the KBRT plan target canmore » achieve the similar target dose coverage, D98,D95,D2,HI and CI had no difference (P≥0.05). The dose of rectum, bladder and femoral heads had no significant differences(P≥0.05). The time was used to design treatment plan was significant reduced. Conclusion: This study shows that postoperative radiotherapy of cervical KBRT plans can achieve the similar target and OARs dose, but the shorter designing time.« less

  13. Targeting of folate-conjugated liposomes with co-entrapped drugs to prostate cancer cells via prostate-specific membrane antigen (PSMA).

    PubMed

    Patil, Yogita; Shmeeda, Hilary; Amitay, Yasmine; Ohana, Patricia; Kumar, Saran; Gabizon, Alberto

    2018-04-19

    Folate-targeted liposomes (FTL) were tested as drug delivery vehicles to PSMA-positive cancer cells. We used FL with co-entrapped mitomycin C lipophilic prodrug (MLP) and doxorubicin (DOX), and the LNCaP prostate cancer cell line which expresses PSMA but is negative for folate receptor. A major increase in cell drug levels was observed when LNCaP cells were incubated with FTL as compared to non-targeted liposomes (NTL). MLP was activated to mitomycin C, and intracellular and nuclear fluorescence of DOX was detected, indicating FTL processing and drug bioavailability. PMPA (2-(phosphonomethyl)-pentanedioic acid), a specific inhibitor of PSMA, blocked the uptake of FTL into LNCaP cells, but did not affect the uptake of FTL into PSMA-deficient and folate receptor-positive KB cells. The cytotoxic activity of drug-loaded FTL was found significantly enhanced when compared to NTL in LNCaP cells. FTL may provide a new tool for targeted therapy of cancers that over-express the PSMA receptor. Copyright © 2018. Published by Elsevier Inc.

  14. Oligo-branched peptides for tumor targeting: from magic bullets to magic forks.

    PubMed

    Falciani, Chiara; Pini, Alessandro; Bracci, Luisa

    2009-02-01

    Selective targeting of tumor cells is the final goal of research and drug discovery for cancer diagnosis, imaging and therapy. After the invention of hybridoma technology, the concept of magic bullet was introduced into the field of oncology, referring to selective killing of tumor cells, by specific antibodies. More recently, small molecules and peptides have also been proposed as selective targeting agents. We analyze the state of the art of tumor-selective agents that are presently available and tested in clinical settings. A novel approach based on 'armed' oligo-branched peptides as tumor targeting agents, is discussed and compared with existing tumor-selective therapies mediated by antibodies, small molecules or monomeric peptides. Oligo-branched peptides could be novel drugs that combine the advantages of antibodies and small molecules.

  15. Quality control for normal liquid-based cytology: Rescreening, high-risk HPV targeted reviewing and/or high-risk HPV detection?

    PubMed Central

    Depuydt, Christophe E; Arbyn, Marc; Benoy, Ina H; Vandepitte, Johan; Vereecken, Annie J; Bogers, Johannes J

    2009-01-01

    The objective of this prospective study was to compare the number of CIN2+cases detected in negative cytology by different quality control (QC) methods. Full rescreening, high-risk (HR) human papillomavirus (HPV)-targeted reviewing and HR HPV detection were compared. Randomly selected negative cytology detected by BD FocalPoint™ (NFR), by guided screening of the prescreened which needed further review (GS) and by manual screening (MS) was used. A 3-year follow-up period was available. Full rescreening of cytology only detected 23.5% of CIN2+ cases, whereas the cytological rescreening of oncogenic positive slides (high-risk HPV-targeted reviewing) detected 7 of 17 CIN2+ cases (41.2%). Quantitative real-time PCR for 15 oncogenic HPV types detected all CIN2+ cases. Relative sensitivity to detect histological CIN2+ was 0.24 for full rescreening, 0.41 for HR-targeted reviewing and 1.00 for HR HPV detection. In more than half of the reviewed negative cytological preparations associated with histological CIN2+cases no morphologically abnormal cells were detected despite a positive HPV test. The visual cut-off for the detection of abnormal cytology was established at 6.5 HR HPV copies/cell. High-risk HPV detection has a higher yield for detection of CIN2+ cases as compared to manual screening followed by 5% full review, or compared to targeted reviewing of smears positive for oncogenic HPV types, and show diagnostic properties that support its use as a QC procedure in cytologic laboratories. PMID:18544049

  16. Test Operations Procedure (TOP) 03-2-827 Test Procedures for Video Target Scoring Using Calibration Lights

    DTIC Science & Technology

    2016-04-04

    Final 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Test Operations Procedure (TOP) 03-2-827 Test Procedures for Video Target Scoring Using...ABSTRACT This Test Operations Procedure (TOP) describes typical equipment and procedures to setup and operate a Video Target Scoring System (VTSS) to...lights. 15. SUBJECT TERMS Video Target Scoring System, VTSS, witness screens, camera, target screen, light pole 16. SECURITY

  17. Comparison of the Sensitivity of Laboratory Diagnostic Methods from a Well-Characterized Outbreak of Mumps in New York City in 2009

    PubMed Central

    Rosen, Jennifer B.; Doll, Margaret K.; McNall, Rebecca J.; McGrew, Marcia; Williams, Nobia; Lopareva, Elena N.; Barskey, Albert E.; Punsalang, Amado; Rota, Paul A.; Oleszko, William R.; Hickman, Carole J.; Zimmerman, Christopher M.; Bellini, William J.

    2013-01-01

    A mumps outbreak in upstate New York in 2009 at a summer camp for Orthodox Jewish boys spread into Orthodox Jewish communities in the Northeast, including New York City. The availability of epidemiologic information, including vaccination records and parotitis onset dates, allowed an enhanced analysis of laboratory methods for mumps testing. Serum and buccal swab samples were collected from 296 confirmed cases with onsets from September through December 2009. All samples were tested using the Centers for Disease Control and Prevention (CDC) capture IgM enzyme immunoassay (EIA) and a real-time reverse transcription-PCR (rRT-PCR) that targets the short hydrophobic gene. A subset of the samples (n = 205) was used to evaluate 3 commercial mumps IgM assays and to assess the sensitivity of using an alternative target gene (nucleoprotein) in the rRT-PCR protocol. Among 115 cases of mumps with 2 documented doses of measles, mumps, and rubella (MMR) vaccine, the CDC capture IgM EIA detected IgM in 51% of serum samples compared to 9% to 24% using three commercial IgM assays. The rRT-PCR that targeted the nucleoprotein gene increased RNA detection by 14% compared to that obtained with the original protocol. The ability to detect IgM improved when serum was collected 3 days or more after symptom onset, whereas sensitivity of RNA detection by rRT-PCR declined when buccal swabs were collected later than 2 days after onset. Selection of testing methods and timing of sample collection are important factors in the ability to confirm infection among vaccinated persons. These results reinforce the need to use virus detection assays in addition to serologic tests. PMID:23324519

  18. Semi-conducting single-walled carbon nanotubes are detrimental when compared to metallic single-walled carbon nanotubes for electrochemical applications.

    PubMed

    Dong, Qi; Nasir, Muhammad Zafir Mohamad; Pumera, Martin

    2017-10-18

    As-synthetized single walled carbon nanotubes (SWCNTs) contain both metallic and semiconducting nanotubes. For the electronics, it is desirable to separate semiconducting SWCNTs (s-SWCNTs) from the metallic ones as s-SWCNTs provide desirable electronic properties. Here we test whether ultrapure semi-conducting single-walled carbon nanotubes (s-SWCNTs) provide advantageous electrochemical properties over the as prepared SWCNTs which contain a mixture of semiconducting and metallic CNTs. We test them as a transducer platform which enhanced the detection of target analytes (ascorbic acid, dopamine, uric acid) when compared to a bare glassy carbon (GC) electrode. Despite that, the two materials exhibit significantly different electrochemical properties and performances. A mixture of m-SWCNTs and s-SWCNTs demonstrated superior performance over ultrapure s-SWCNTs with greater peak currents and pronounced shift in peak potentials to lower values in cyclic and differential pulse voltammetry for the detection of target analytes. The mixture of m- and s-SWCNTs displayed about a 4 times improved heterogeneous electron transfer rate as compared to bare GC and a 2 times greater heterogeneous electron transfer rate than s-SWCNTs, demonstrating that ultrapure SWCNTs do not provide any major enhancement over the as prepared SWCNTs.

  19. Simulation of intrafraction motion and overall geometric accuracy of a frameless intracranial radiosurgery process

    PubMed Central

    Walker, Luke; Chinnaiyan, Prakash; Forster, Kenneth

    2008-01-01

    We conducted a comprehensive evaluation of the clinical accuracy of an image‐guided frameless intracranial radiosurgery system. All links in the process chain were tested. Using healthy volunteers, we evaluated a novel method to prospectively quantify the range of target motion for optimal determination of the planning target volume (PTV) margin. The overall system isocentric accuracy was tested using a rigid anthropomorphic phantom containing a hidden target. Intrafraction motion was simulated in 5 healthy volunteers. Reinforced head‐and‐shoulders thermoplastic masks were used for immobilization. The subjects were placed in a treatment position for 15 minutes (the maximum expected time between repeated isocenter localizations) and the six‐degrees‐of‐freedom target displacements were recorded with high frequency by tracking infrared markers. The markers were placed on a customized piece of thermoplastic secured to the head independently of the immobilization mask. Additional data were collected with the subjects holding their breath, talking, and deliberately moving. As compared with fiducial matching, the automatic registration algorithm did not introduce clinically significant errors (<0.3 mm difference). The hidden target test confirmed overall system isocentric accuracy of ≤1 mm (total three‐dimensional displacement). The subjects exhibited various patterns and ranges of head motion during the mock treatment. The total displacement vector encompassing 95% of the positional points varied from 0.4 mm to 2.9 mm. Pre‐planning motion simulation with optical tracking was tested on volunteers and appears promising for determination of patient‐specific PTV margins. Further patient study is necessary and is planned. In the meantime, system accuracy is sufficient for confident clinical use with 3 mm PTV margins. PACS number: 87.53.Ly

  20. A pseudoisochromatic test of color vision for human infants.

    PubMed

    Mercer, Michele E; Drodge, Suzanne C; Courage, Mary L; Adams, Russell J

    2014-07-01

    Despite the development of experimental methods capable of measuring early human color vision, we still lack a procedure comparable to those used to diagnose the well-identified congenital and acquired color vision anomalies in older children, adults, and clinical patients. In this study, we modified a pseudoisochromatic test to make it more suitable for young infants. Using a forced choice preferential looking procedure, 216 3-to-23-mo-old babies were tested with pseudoisochromatic targets that fell on either a red/green or a blue/yellow dichromatic confusion axis. For comparison, 220 color-normal adults and 22 color-deficient adults were also tested. Results showed that all babies and adults passed the blue/yellow target but many of the younger infants failed the red/green target, likely due to the interaction of the lingering immaturities within the visual system and the small CIE vector distance within the red/green plate. However, older (17-23 mo) infants, color- normal adults and color-defective adults all performed according to expectation. Interestingly, performance on the red/green plate was better among female infants, well exceeding the expected rate of genetic dimorphism between genders. Overall, with some further modification, the test serves as a promising tool for the detection of early color vision anomalies in early human life. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. A Pilot Study for Applying an Extravehicular Activity Exercise Prebreathe Protocol to the International Space Station

    NASA Technical Reports Server (NTRS)

    Woodruff, Kristin K.; Johnson, Anyika N.; Lee, Stuart M. C.; Gernhardt, Michael; Schneider, Suzanne M.; Foster, Philip P.

    2000-01-01

    Decompression sickness (DCS) is a serious risk to astronauts performing extravehicular activity (EVA). To reduce this risk, the addition of ten minutes of moderate exercise (75% VO2pk) during prebreathe has been shown to decrease the total prebreathe time from 4 to 2 hours and to decrease the incidence of DCS. The overall purpose of this pilot study was to develop an exercise protocol using flight hardware and an in-flight physical fitness cycle test to perform prebreathe exercise before an EVA. Eleven subjects volunteered to participate in this study. The first objective of this study was to compare the steady-state heart rate (HR) and oxygen consumption (VO2) from a submaximal arm and leg exercise (ALE) session with those predicted from a maximal ALE test. The second objective was to compare the steady-state HR and V02 from a submaximal elastic tube and leg exercise (TLE) session with those predicted from the maximal ALE test. The third objective involved a comparison of the maximal ALE test with a maximal leg-only (LE) test to conform to the in- flight fitness assessment test. The 75% VO2pk target HR from the LE test was significantly less than the target HR from the ALE test. Prescribing exercise using data from the maximal ALE test resulted in the measured submaximal values being higher than predicted VO2 and HR. The results of this pilot study suggest that elastic tubing is valid during EVA prebreathe as a method of arm exercise with the flight leg ergometer and it is recommended that prebreathe countermeasure exercise protocol incorporate this method.

  2. Comparison of two quantum dots for bioluminescence resonance energy transfer based on nucleic acid detection

    NASA Astrophysics Data System (ADS)

    Zhang, Daohong

    2017-05-01

    The performance of two commercially available quantum dots, quantum dot 605 (Qd605) and quantum dot 625 (Qd625), was tested and compared in the sensing system developed by our group previously. The sandwich format sensing system employed Renilla luciferase (Rluc) and quantum dots (Qds), could report the presence of targets with increasing bioluminescent resonance energy transfer (BRET) signal. The best spacing between the Rluc and Qds probes were 15 nucleotides. Both of Qd605 and Qd625 sensing system could quantify nucleic acid targets through 1-min hybridization from 0.2 picomoles. However, the Qd625 system showed higher BRET signal and better selectivity. Therefore, Qd625 is a better choice in this system compared to Qd605.

  3. Diagnostic molecular microbiology: a 2013 snapshot.

    PubMed

    Fairfax, Marilynn Ransom; Salimnia, Hossein

    2013-12-01

    Molecular testing has a large and increasing role in the diagnosis of infectious diseases. It has evolved significantly since the first probe tests were FDA approved in the early 1990s. This article highlights the uses of molecular techniques in diagnostic microbiology, including "older," as well as innovative, probe techniques, qualitative and quantitative RT-PCR, highly multiplexed PCR panels, some of which use sealed microfluidic test cartridges, MALDI TOF, and nuclear magnetic resonance. Tests are grouped together by technique and target. Tests with similar roles for similar analytes are compared with respect to benefits, drawbacks, and possible problems. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. A hybrid deconvolution approach for estimation of in vivo non-displaceable binding for brain PET targets without a reference region

    PubMed Central

    Mann, J. John; Ogden, R. Todd

    2017-01-01

    Background and aim Estimation of a PET tracer’s non-displaceable distribution volume (VND) is required for quantification of specific binding to its target of interest. VND is generally assumed to be comparable brain-wide and is determined either from a reference region devoid of the target, often not available for many tracers and targets, or by imaging each subject before and after blocking the target with another molecule that has high affinity for the target, which is cumbersome and involves additional radiation exposure. Here we propose, and validate for the tracers [11C]DASB and [11C]CUMI-101, a new data-driven hybrid deconvolution approach (HYDECA) that determines VND at the individual level without requiring either a reference region or a blocking study. Methods HYDECA requires the tracer metabolite-corrected concentration curve in blood plasma and uses a singular value decomposition to estimate the impulse response function across several brain regions from measured time activity curves. HYDECA decomposes each region’s impulse response function into the sum of a parametric non-displaceable component, which is a function of VND, assumed common across regions, and a nonparametric specific component. These two components differentially contribute to each impulse response function. Different regions show different contributions of the two components, and HYDECA examines data across regions to find a suitable common VND. HYDECA implementation requires determination of two tuning parameters, and we propose two strategies for objectively selecting these parameters for a given tracer: using data from blocking studies, and realistic simulations of the tracer. Using available test-retest data, we compare HYDECA estimates of VND and binding potentials to those obtained based on VND estimated using a purported reference region. Results For [11C]DASB and [11C]CUMI-101, we find that regardless of the strategy used to optimize the tuning parameters, HYDECA provides considerably less biased estimates of VND than those obtained, as is commonly done, using a non-ideal reference region. HYDECA test-retest reproducibility is comparable to that obtained using a VND determined from a non-ideal reference region, when considering the binding potentials BPP and BPND. Conclusions HYDECA can provide subject-specific estimates of VND without requiring a blocking study for tracers and targets for which a valid reference region does not exist. PMID:28459878

  5. Panoramic Night Vision Goggle Testing For Diagnosis and Repair

    DTIC Science & Technology

    2000-01-01

    Visual Acuity Visual Acuity [ Marasco & Task, 1999] measures how well a human observer can see high contrast targets at specified light levels through...grid through the PNVG in-board and out-board channels simultaneously and comparing the defects to the size of grid features ( Marasco & Task, 1999). The

  6. 4D Optimization of Scanned Ion Beam Tracking Therapy for Moving Tumors

    PubMed Central

    Eley, John Gordon; Newhauser, Wayne David; Lüchtenborg, Robert; Graeff, Christian; Bert, Christoph

    2014-01-01

    Motion mitigation strategies are needed to fully realize the theoretical advantages of scanned ion beam therapy for patients with moving tumors. The purpose of this study was to determine whether a new four-dimensional (4D) optimization approach for scanned-ion-beam tracking could reduce dose to avoidance volumes near a moving target while maintaining target dose coverage, compared to an existing 3D-optimized beam tracking approach. We tested these approaches computationally using a simple 4D geometrical phantom and a complex anatomic phantom, that is, a 4D computed tomogram of the thorax of a lung cancer patient. We also validated our findings using measurements of carbon-ion beams with a motorized film phantom. Relative to 3D-optimized beam tracking, 4D-optimized beam tracking reduced the maximum predicted dose to avoidance volumes by 53% in the simple phantom and by 13% in the thorax phantom. 4D-optimized beam tracking provided similar target dose homogeneity in the simple phantom (standard deviation of target dose was 0.4% versus 0.3%) and dramatically superior homogeneity in the thorax phantom (D5-D95 was 1.9% versus 38.7%). Measurements demonstrated that delivery of 4D-optimized beam tracking was technically feasible and confirmed a 42% decrease in maximum film exposure in the avoidance region compared with 3D-optimized beam tracking. In conclusion, we found that 4D-optimized beam tracking can reduce the maximum dose to avoidance volumes near a moving target while maintaining target dose coverage, compared with 3D-optimized beam tracking. PMID:24889215

  7. I can see what you are saying: Auditory labels reduce visual search times.

    PubMed

    Cho, Kit W

    2016-10-01

    The present study explored the self-directed-speech effect, the finding that relative to silent reading of a label (e.g., DOG), saying it aloud reduces visual search reaction times (RTs) for locating a target picture among distractors. Experiment 1 examined whether this effect is due to a confound in the differences in the number of cues in self-directed speech (two) vs. silent reading (one) and tested whether self-articulation is required for the effect. The results showed that self-articulation is not required and that merely hearing the auditory label reduces visual search RTs relative to silent reading. This finding also rules out the number of cues confound. Experiment 2 examined whether hearing an auditory label activates more prototypical features of the label's referent and whether the auditory-label benefit is moderated by the target's imagery concordance (the degree to which the target picture matches the mental picture that is activated by a written label for the target). When the target imagery concordance was high, RTs following the presentation of a high prototypicality picture or auditory cue were comparable and shorter than RTs following a visual label or low prototypicality picture cue. However, when the target imagery concordance was low, RTs following an auditory cue were shorter than the comparable RTs following the picture cues and visual-label cue. The results suggest that an auditory label activates both prototypical and atypical features of a concept and can facilitate visual search RTs even when compared to picture primes. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Minimizing the Disruptive Effects of Prospective Memory in Simulated Air Traffic Control

    PubMed Central

    Loft, Shayne; Smith, Rebekah E.; Remington, Roger

    2015-01-01

    Prospective memory refers to remembering to perform an intended action in the future. Failures of prospective memory can occur in air traffic control. In two experiments, we examined the utility of external aids for facilitating air traffic management in a simulated air traffic control task with prospective memory requirements. Participants accepted and handed-off aircraft and detected aircraft conflicts. The prospective memory task involved remembering to deviate from a routine operating procedure when accepting target aircraft. External aids that contained details of the prospective memory task appeared and flashed when target aircraft needed acceptance. In Experiment 1, external aids presented either adjacent or non-adjacent to each of the 20 target aircraft presented over the 40min test phase reduced prospective memory error by 11% compared to a condition without external aids. In Experiment 2, only a single target aircraft was presented a significant time (39min–42min) after presentation of the prospective memory instruction, and the external aids reduced prospective memory error by 34%. In both experiments, costs to the efficiency of non-prospective memory air traffic management (non-target aircraft acceptance response time, conflict detection response time) were reduced by non-adjacent aids compared to no aids or adjacent aids. In contrast, in both experiments, the efficiency of the prospective memory air traffic management (target aircraft acceptance response time) was facilitated by adjacent aids compared to non-adjacent aids. Together, these findings have potential implications for the design of automated alerting systems to maximize multi-task performance in work settings where operators monitor and control demanding perceptual displays. PMID:24059825

  9. 4D optimization of scanned ion beam tracking therapy for moving tumors

    NASA Astrophysics Data System (ADS)

    Eley, John Gordon; Newhauser, Wayne David; Lüchtenborg, Robert; Graeff, Christian; Bert, Christoph

    2014-07-01

    Motion mitigation strategies are needed to fully realize the theoretical advantages of scanned ion beam therapy for patients with moving tumors. The purpose of this study was to determine whether a new four-dimensional (4D) optimization approach for scanned-ion-beam tracking could reduce dose to avoidance volumes near a moving target while maintaining target dose coverage, compared to an existing 3D-optimized beam tracking approach. We tested these approaches computationally using a simple 4D geometrical phantom and a complex anatomic phantom, that is, a 4D computed tomogram of the thorax of a lung cancer patient. We also validated our findings using measurements of carbon-ion beams with a motorized film phantom. Relative to 3D-optimized beam tracking, 4D-optimized beam tracking reduced the maximum predicted dose to avoidance volumes by 53% in the simple phantom and by 13% in the thorax phantom. 4D-optimized beam tracking provided similar target dose homogeneity in the simple phantom (standard deviation of target dose was 0.4% versus 0.3%) and dramatically superior homogeneity in the thorax phantom (D5-D95 was 1.9% versus 38.7%). Measurements demonstrated that delivery of 4D-optimized beam tracking was technically feasible and confirmed a 42% decrease in maximum film exposure in the avoidance region compared with 3D-optimized beam tracking. In conclusion, we found that 4D-optimized beam tracking can reduce the maximum dose to avoidance volumes near a moving target while maintaining target dose coverage, compared with 3D-optimized beam tracking.

  10. Accuracy of torque-limiting devices: A comparative evaluation.

    PubMed

    Albayrak, Haydar; Gumus, Hasan Onder; Tursun, Funda; Kocaagaoglu, Hasan Huseyin; Kilinc, Halil Ibrahim

    2017-01-01

    To prevent the loosening of implant screws, clinicians should be aware of the output torque values needed to achieve the desired preload. Accurate torque-control devices are crucial in this regard; however, little information is currently available comparing the accuracy of mechanical with that of electronic torque-control devices. The purpose of this in vitro study was to identify and compare the accuracy of different types of torque-control devices. Devices from 5 different dental implant manufacturers were evaluated, including 2 spring-type (Straumann, Implance) mechanical devices (MTLD), 2 friction-type (Biohorizons, Dyna) MTLDs, and 1 (Megagen) electronic torque-control device (ETLD). For each manufacturer, 5 devices were tested 5 times with a digital torque tester, and the average for each device was calculated and recorded. The percentage of absolute deviations from the target torque values (PERDEV) were calculated and compared by using 1-way ANOVA. A 1-sample t test was used to evaluate the ability of each device to achieve its target torque value within a 95% confidence interval for the true population mean of measured values (α=.05 for all statistical analyses). One-way ANOVAs revealed statistically significant differences among torque-control devices (P<.001). ETLD showed higher PERDEVs (28.33 ±9.53) than MTLDs (P<.05), whereas PERDEVS of friction-type (7.56 ±3.64) and spring-type (10.85 ±4.11) MTLDs did not differ significantly. In addition, devices produced by Megagen had a significantly higher (P<.05) PERDEV (28.33 ±9.53) other devices, whereas no differences were found in devices manufactured by Biohorizons (7.31 ±5.34), Dyna (7.82 ±1.08), Implance (8.43 ±4.77), and Straumann (13.26 ±0.79). However, 1-sample t tests showed none of the torque-control devices evaluated in this study were capable of achieving their target torque values (P<.05). Within the limitations of this in vitro study, MTLDs were shown to be significantly more accurate than ETLDs. However, none of the torque-control devices evaluated were able to meet their target torque values successfully. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  11. The impact of body-part-naming training on the accuracy of imitative performances in 2- to 3-year-old children.

    PubMed

    Camões-Costa, Vera; Erjavec, Mihela; Horne, Pauline J

    2011-11-01

    A series of three experiments explored the relationship between 3-year-old children's ability to name target body parts and their untrained matching of target hand-to-body touches. Nine participants, 3 per experiment, were presented with repeated generalized imitation tests in a multiple-baseline procedure, interspersed with step-by-step training that enabled them to (i) tact the target locations on their own and the experimenter's bodies or (ii) respond accurately as listeners to the experimenter's tacts of the target locations. Prompts for on-task naming of target body parts were also provided later in the procedure. In Experiment 1, only tact training followed by listener probes were conducted; in Experiment 2, tacting was trained first and listener behavior second, whereas in Experiment 3 listener training preceded tact training. Both tact and listener training resulted in emergence of naming together with significant and large improvements in the children's matching performances; this was true for each child and across most target gestures. The present series of experiments provides evidence that naming--the most basic form of self-instructional behavior--may be one means of establishing untrained matching as measured in generalized imitation tests. This demonstration has a bearing on our interpretation of imitation reported in the behavior analytic, cognitive developmental, and comparative literature.

  12. Stimulus-reinforcer relations established during training determine resistance to extinction and relapse via reinstatement.

    PubMed

    Bai, John Y H; Jonas Chan, C K; Elliffe, Douglas; Podlesnik, Christopher A

    2016-11-01

    The baseline rate of a reinforced target response decreases with the availability of response-independent sources of alternative reinforcement; however, resistance to disruption and relapse increases. Because many behavioral treatments for problem behavior include response-dependent reinforcement of alternative behavior, the present study assessed whether response-dependent alternative reinforcement also decreases baseline response rates but increases resistance to extinction and relapse. We reinforced target responding at equal rates across two components of a multiple schedule with pigeons. We compared resistance to extinction and relapse via reinstatement of (1) a target response trained concurrently with a reinforced alternative response in one component with (2) a target response trained either concurrently or in separate components from the alternative response across conditions. Target response rates trained alone in baseline were higher but resistance to extinction and relapse via reinstatement tests were greater after training concurrently with the alternative response. In another assessment, training target and alternative responding together, but separating them during extinction and reinstatement tests, produced equal resistance to extinction and relapse. Together, these findings are consistent with behavioral momentum theory-operant response-reinforcer relations determined baseline response rates but Pavlovian stimulus-reinforcer relations established during training determined resistance to extinction and relapse. These findings imply that reinforcing alternative behavior to treat problem behavior could initially reduce rates but increase persistence. © 2016 Society for the Experimental Analysis of Behavior.

  13. The Impact of Body-Part-Naming Training on the Accuracy of Imitative Performances in 2- to 3-Year-Old Children

    PubMed Central

    Camões-Costa, Vera; Erjavec, Mihela; Horne, Pauline J

    2011-01-01

    A series of three experiments explored the relationship between 3-year-old children's ability to name target body parts and their untrained matching of target hand-to-body touches. Nine participants, 3 per experiment, were presented with repeated generalized imitation tests in a multiple-baseline procedure, interspersed with step-by-step training that enabled them to (i) tact the target locations on their own and the experimenter's bodies or (ii) respond accurately as listeners to the experimenter's tacts of the target locations. Prompts for on-task naming of target body parts were also provided later in the procedure. In Experiment 1, only tact training followed by listener probes were conducted; in Experiment 2, tacting was trained first and listener behavior second, whereas in Experiment 3 listener training preceded tact training. Both tact and listener training resulted in emergence of naming together with significant and large improvements in the children's matching performances; this was true for each child and across most target gestures. The present series of experiments provides evidence that naming —the most basic form of self-instructional behavior—may be one means of establishing untrained matching as measured in generalized imitation tests. This demonstration has a bearing on our interpretation of imitation reported in the behavior analytic, cognitive developmental, and comparative literature. PMID:22084492

  14. Hypervelocity penetration against mechanical properties of target materials

    NASA Astrophysics Data System (ADS)

    Kamarudin, Khairul Hasni; Abdullah, Mohamad Faizal; Zaidi, Ahmad Mujahid Ahmad; Nor, Norazman M.; Ismail, Ariffin; Yusof, Mohammed Alias; Hilmi, Ahmad Humaizi

    2018-02-01

    This paper study the mechanical properties behavior of metal plates against hypervelocity penetration caused by shaped charge. Five different materials were used as target specimen fabricated from welded stacks of material plates, namely Rolled Homogeneous Armor (RHA), Hardox-500, mild steel, aluminum and brass. Specimens had undergone an initial monolithic test consist of tensile tests and microstructure observations, followed by series of hydrodynamics penetration blast tests using shape charge mechanism. Results from blast test shows that the least penetrated specimen is RHA (58mm) followed by Hardox-500 (92 mm), mild steel (110 mm), Brass (155 mm) and aluminum 238 mm). Comparing these with the specimen yield strength from the tensile test results shows that Hardox-500 has higher yield strength (Sy) followed by RHA, mild steel, brass and aluminum, which are 1370 MPa, 1320 MPa, 280,221 respectively, which are not inversely proportional to the penetration. However, the ultimate tensile strength (Sut) where the RHA were the highest followed by Hardox-500, mild steel, brass and aluminum, were inversely proportional with the depth of penetration. The penetration results also show consistence relation with energy absorption.

  15. ESI-MS studies of the reactions of novel platinum(II) complexes containing O,O'-chelated acetylacetonate and sulfur ligands with selected model proteins.

    PubMed

    Marzo, Tiziano; De Pascali, Sandra A; Gabbiani, Chiara; Fanizzi, Francesco P; Messori, Luigi; Pratesi, Alessandro

    2017-08-01

    A group of mixed-ligand Pt(II) complexes bearing acetylacetonate and sulphur ligands were recently developed in the University of Lecce as a new class of prospective anticancer agents that manifested promising pharma-cological properties in preliminary in vitro and in vivo tests. Though modelled on the basis of cisplatin, these Pt(II) complexes turned out to exhibit a profoundly distinct mode of action as they were found to act mainly on non-genomic targets rather than on DNA. Accordingly, we have explored here their reactions with two representative model proteins through an established ESI-MS procedure with the aim to describe their general interaction mechanism with protein targets. A pronounced reactivity with the tested proteins was indeed documented; the nature of the resulting metallodrug-protein interactions could be characterised in depth in the various cases. Preferential binding to protein targets compared to DNA is supported by independent ICP-OES measurements. The implications of these findings are discussed.

  16. SU-F-T-36: Dosimetric Comparison of Point Based Vs. Target Based Prescription for Intracavitary Brachytherapy in Cancer of the Cervix

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ashenafi, M; McDonald, D; Peng, J

    Purpose: Improved patient imaging used for planning the treatment of cervical cancer with Tandem and Ovoid (T&O) Intracavitary high-dose-rate brachytherapy (HDR) now allows for 3D delineation of target volumes and organs-at-risk. However, historical data relies on the conventional point A-based planning technique. A comparative dosimetric study was performed by generating both target-based (TBP) and point-based (PBP) plans for ten clinical patients. Methods: Treatment plans created using Elekta Oncentra v. 4.3 for ten consecutive cervical cancer patients were analyzed. All patients were treated with HDR using the Utrecht T&O applicator. Both CT and MRI imaging modalities were utilized to delineate clinicalmore » target volume (CTV) and organs-at-risk (rectum, sigmoid, bladder, and small bowel). Point A (left and right), vaginal mucosa, and ICRU rectum and bladder points were defined on CT. Two plans were generated for each patient using two prescription methods (PBP and TBP). 7Gy was prescribed to each point A for each PBP plan and to the target D90% for each TBP plan. Target V90%, V100%, and V200% were evaluated. In addition, D0.1cc and D2cc were analyzed for each organ-at-risk. Differences were assessed for statistical significance (p<0.05) by use of Student’s t-test. Results: Target coverage was comparable for both planning methods, with each method providing adequate target coverage. TBP showed lower absolute dose to the target volume than PBP (D90% = 7.0Gy vs. 7.4Gy, p=0.028), (V200% = 10.9cc vs. 12.8cc, p=0.014), (ALeft = 6.4Gy vs. 7Gy, p=0.009), and (ARight = 6.4Gy vs. 7Gy, p=0.013). TBP also showed a statistically significant reduction in bladder, rectum, small bowel, and sigmoid doses compared to PBP. There was no statistically significant difference in vaginal mucosa or ICRU-defined rectum and bladder dose. Conclusion: Target based prescription resulted in substantially lower dose to delineated organs-at-risk compared to point based prescription, while maintaining similar target coverage.« less

  17. R&D of A MW-class solid-target for a spallation neutron source

    NASA Astrophysics Data System (ADS)

    Kawai, Masayoshi; Furusaka, Michihiro; Kikuchi, Kenji; Kurishita, Hiroaki; Watanabe, Ryuzo; Li, Jing-Feng; Sugimoto, Katsuhisa; Yamamura, Tsutomu; Hiraoka, Yutaka; Abe, Katsunori; Hasegawa, Akira; Yoshiie, Masatoshi; Takenaka, Hiroyuki; Mishima, Katsuichiro; Kiyanagi, Yoshiaki; Tanabe, Tetsuo; Yoshida, Naoaki; Igarashi, Tadashi

    2003-05-01

    R&D for a MW-class solid target composed of tungsten was undertaken to produce a pulsed intense neutron source for a future neutron scattering-facility. In order to solve the corrosion of tungsten, tungsten target blocks were clad with tantalum by means of HIP'ing, brazing and electrolytic coating in a molten salt bath. The applicability of the HIP'ing method was tested through fabricating target blocks for KENS (spallation neutron source at KEK). A further investigation to certify the optimum HIP conditions was made with the small punch test method. The results showed that the optimum temperature was 1500 °C at which the W/Ta interface gave the strongest fracture strength. In the case of the block with a hole for thermocouple, it was found that the fabrication preciseness of a straight hole and a tantalum sheath influenced the results. The development of a tungsten stainless-steel alloy was tried to produce a bare tungsten target, using techniques in powder metallurgy. Corrosion tests for various tungsten alloys were made while varying the water temperature and velocity. The mass loss of tungsten in very slow water at 180 °C was as low as 0.022 mg/y, but increased remarkably with water velocity. Simulation experiments for radiation damage to supplement the STIP-III experiments were made to investigate material hardening by hydrogen and helium, and microstructures irradiated by electrons. Both experiments showed consistent results on the order of the dislocation numbers and irradiation hardness among the different tungsten materials. Thermal-hydraulic designs were made for two types of solid target system of tungsten: slab and rod geometry as a function of the proton beam power. The neutronic performance of a solid target system was compared with that of mercury target based on Monte Carlo calculations by using the MCNP code.

  18. Anti-CD22–chimeric antigen receptors targeting B-cell precursor acute lymphoblastic leukemia

    PubMed Central

    Haso, Waleed; Lee, Daniel W.; Shah, Nirali N.; Stetler-Stevenson, Maryalice; Yuan, Constance M.; Pastan, Ira H.; Dimitrov, Dimiter S.; Morgan, Richard A.; FitzGerald, David J.; Barrett, David M.; Wayne, Alan S.; Mackall, Crystal L.

    2013-01-01

    Immune targeting of B-cell malignancies using chimeric antigen receptors (CARs) is a promising new approach, but critical factors impacting CAR efficacy remain unclear. To test the suitability of targeting CD22 on precursor B-cell acute lymphoblastic leukemia (BCP-ALL), lymphoblasts from 111 patients with BCP-ALL were assayed for CD22 expression and all were found to be CD22-positive, with median CD22 expression levels of 3500 sites/cell. Three distinct binding domains targeting CD22 were fused to various TCR signaling domains ± an IgG heavy chain constant domain (CH2CH3) to create a series of vector constructs suitable to delineate optimal CAR configuration. CARs derived from the m971 anti-CD22 mAb, which targets a proximal CD22 epitope demonstrated superior antileukemic activity compared with those incorporating other binding domains, and addition of a 4-1BB signaling domain to CD28.CD3ζ constructs diminished potency, whereas increasing affinity of the anti-CD22 binding motif, and extending the CD22 binding domain away from the membrane via CH2CH3 had no effect. We conclude that second-generation m971 mAb-derived anti-CD22 CARs are promising novel therapeutics that should be tested in BCP-ALL. PMID:23243285

  19. Anti-CD22-chimeric antigen receptors targeting B-cell precursor acute lymphoblastic leukemia.

    PubMed

    Haso, Waleed; Lee, Daniel W; Shah, Nirali N; Stetler-Stevenson, Maryalice; Yuan, Constance M; Pastan, Ira H; Dimitrov, Dimiter S; Morgan, Richard A; FitzGerald, David J; Barrett, David M; Wayne, Alan S; Mackall, Crystal L; Orentas, Rimas J

    2013-02-14

    Immune targeting of B-cell malignancies using chimeric antigen receptors (CARs) is a promising new approach, but critical factors impacting CAR efficacy remain unclear. To test the suitability of targeting CD22 on precursor B-cell acute lymphoblastic leukemia (BCP-ALL), lymphoblasts from 111 patients with BCP-ALL were assayed for CD22 expression and all were found to be CD22-positive, with median CD22 expression levels of 3500 sites/cell. Three distinct binding domains targeting CD22 were fused to various TCR signaling domains ± an IgG heavy chain constant domain (CH2CH3) to create a series of vector constructs suitable to delineate optimal CAR configuration. CARs derived from the m971 anti-CD22 mAb, which targets a proximal CD22 epitope demonstrated superior antileukemic activity compared with those incorporating other binding domains, and addition of a 4-1BB signaling domain to CD28.CD3 constructs diminished potency, whereas increasing affinity of the anti-CD22 binding motif, and extending the CD22 binding domain away from the membrane via CH2CH3 had no effect. We conclude that second-generation m971 mAb-derived anti-CD22 CARs are promising novel therapeutics that should be tested in BCP-ALL.

  20. General practice variation in spirometry testing among patients receiving first-time prescriptions for medication targeting obstructive lung disease in Denmark: a population-based observational study

    PubMed Central

    2013-01-01

    Background Spirometry testing is essential to confirm an obstructive lung disease, but studies have reported that a large proportion of patients diagnosed with COPD or asthma have no history of spirometry testing. Also, it has been shown that many patients are prescribed medication for obstructive lung disease without a relevant diagnosis or spirometry test registered. General practice characteristics have been reported to influence diagnosis and management of several chronic diseases. However, these findings are inconsistent, and it is uncertain whether practice characteristics influence spirometry testing among patients receiving medication for obstructive lung disease. The aim of this study was therefore to examine if practice characteristics are associated with spirometry testing among patients receiving first-time prescriptions for medication targeting obstructive lung disease. Methods A national register-based cohort study was performed. All patients over 18 years receiving first-time prescriptions for medication targeting obstructive lung disease in 2008 were identified and detailed patient-specific data on sociodemographic status and spirometry tests were extracted. Information on practice characteristics like number of doctors, number of patients per doctor, training practice status, as well as age and gender of the general practitioners was linked to each medication user. Results Partnership practices had a higher odds ratio (OR) of performing spirometry compared with single-handed practices (OR 1.24, CI 1.09-1.40). We found a significant association between increasing general practitioner age and decreasing spirometry testing. This tendency was most pronounced among partnership practices, where doctors over 65 years had the lowest odds of spirometry testing (OR 0.25, CI 0.10-0.61). Training practice status was significantly associated with spirometry testing among single-handed practices (OR 1.40, CI 1.10-1.79). Conclusion Some of the variation in spirometry testing among patients receiving first-time prescriptions for medication targeting obstructive lung disease was associated with practice characteristics. This variation in performance may indicate a potential for quality improvement. PMID:23923987

  1. [Examinations with the Cardiff Acuity Test].

    PubMed

    Gräf, M; Becker, R; Neff, A; Kaufmann, H

    1996-08-01

    Recently, a new preferential looking (PL) test has been presented for measuring visual acuity in infants and young children (Cardiff Acuity Test, CAT). The PL target is a schematic vanishing picture composed of isoluminant lines with different spatial orientations. Fifty-three healthy children (4-34 months, group 1), 28 (4-35 months) children at risk for amblyopia due to strabismus (group 2), 19 healthy subjects, and 157 patients (group 3) were tested with the CAT. In group 2 the CAT was compared with the fixation preference test. In group 3 the CAT was compared with a recognition test (Landolt C test). In group 1 the interocular difference of the CAT data was a maximum of 1 dB (70% 0 dB, 30% 1 dB, 1/3 so-called octave). Thus, an interocular difference of > 1 dB was considered to be suggestive of monocular or asymmetrical visual impairment. The maximum value 6/6 was frequently achieved (RE 44%, LE 36%, > 18 months RE 57%, LE 46%). In group 2 only 20% of the monolateral strabismic children showed an interocular difference > 1 dB in the CAT. In group 3 we found significant correlations between the CAT and Landolt acuity. A ratio of about 1.7/1 between CAT and Landolt acuity remained constant in cataract eyes as compared to healthy eyes. In amblyopic eyes due to strabismus this ratio was 3.7/1. Thus, amblyopia was underestimated with the CAT. Without limiting the examination distance, interocular differences > 1 dB in the CAT occurred in 52% of the strabismic amblyopic patients (potential sensitivity). At a distance of 1 m this rate decreased to 22% (real sensitivity). In conclusion, the CAT definitely lacks sensitivity for strabismic amblyopia. The data suggest that the real sensitivity could be improved by using higher spatial frequencies. The use of familiar shapes instead of gratings such as PL targets affects cooperation favorably in 12- to 36-month-old children.

  2. Aphasic Patients Exhibit a Reversal of Hemispheric Asymmetries in Categorical Color Discrimination

    PubMed Central

    Paluy, Yulia; Gilbert, Aubrey L.; Baldo, Juliana V.; Dronkers, Nina F.; Ivry, Richard B.

    2010-01-01

    Patients with left hemisphere (LH) or right hemisphere (RH) brain injury due to stroke were tested on a speeded, color discrimination task in which two factors were manipulated: 1) the categorical relationship between the target and the distracters and 2) the visual field in which the target was presented. Similar to controls, the RH patients were faster in detecting targets in the right visual field when the target and distracters had different color names compared to when their names were the same. This effect was absent in the LH patients, consistent with the hypothesis that injury to the left hemisphere handicaps the automatic activation of lexical codes. Moreover, the LH patients showed a reversed effect, such that the advantage of different target-distracter names was now evident for targets in the left visual field. This reversal may suggest a reorganization of the color lexicon in the right hemisphere following left hemisphere brain injury and/or the unmasking of a heightened right hemisphere sensitivity to color categories. PMID:21216454

  3. Predicting new molecular targets for known drugs

    PubMed Central

    Keiser, Michael J.; Setola, Vincent; Irwin, John J.; Laggner, Christian; Abbas, Atheir; Hufeisen, Sandra J.; Jensen, Niels H.; Kuijer, Michael B.; Matos, Roberto C.; Tran, Thuy B.; Whaley, Ryan; Glennon, Richard A.; Hert, Jérôme; Thomas, Kelan L.H.; Edwards, Douglas D.; Shoichet, Brian K.; Roth, Bryan L.

    2009-01-01

    Whereas drugs are intended to be selective, at least some bind to several physiologic targets, explaining both side effects and efficacy. As many drug-target combinations exist, it would be useful to explore possible interactions computationally. Here, we compared 3,665 FDA-approved and investigational drugs against hundreds of targets, defining each target by its ligands. Chemical similarities between drugs and ligand sets predicted thousands of unanticipated associations. Thirty were tested experimentally, including the antagonism of the β1 receptor by the transporter inhibitor Prozac, the inhibition of the 5-HT transporter by the ion channel drug Vadilex, and antagonism of the histamine H4 receptor by the enzyme inhibitor Rescriptor. Overall, 23 new drug-target associations were confirmed, five of which were potent (< 100 nM). The physiological relevance of one such, the drug DMT on serotonergic receptors, was confirmed in a knock-out mouse. The chemical similarity approach is systematic and comprehensive, and may suggest side-effects and new indications for many drugs. PMID:19881490

  4. Perceptions of plagiarisers: The influence of target physical attractiveness, transgression severity, and sex on attributions of guilt and punishment.

    PubMed

    Swami, Viren; Arthey, Elizabeth; Furnham, Adrian

    2017-09-01

    The attractiveness-leniency effect (ALE) suggests that physically attractive targets are less likely to be perceived as guilty compared to less attractive targets. Here, we tested the ALE in relation to attributions of students who have committed plagiarism. British adults (N=165) were shown one of eight vignette-photograph pairings varying in target sex (female/male), physical attractiveness (high/low), and transgression severity (serious/minor), and provided attributions of guilt and severity of punishment. Analyses of variance revealed significant interactions between attractiveness and transgression severity for both dependent measures. Attractive targets were perceived as guiltier and deserving of more severe punishments in the serious transgression condition, but there was no significant difference between attractive and less attractive targets in the minor transgression condition. These results are discussed in terms of a reverse attribution bias, in which attractive individuals are judged more negatively when they fail to live up to higher standards of conduct. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Applying Disruptive Preference Test Protocols to Increase the Number of "No Preference" Responses in the Placebo Pair, Using Chinese Consumers.

    PubMed

    Xia, Yixun; Zhong, Fang; O'Mahony, Michael

    2016-09-01

    One form of paired preference test protocol requires consumers to assess 2 pairs of products. One is the target pair under consideration, while the other is a putatively identical pair named the "placebo pair" which is also presented as a control. Counterintuitively, the majority of consumers report preferences when presented with the placebo pair. Their response frequencies are hypothesized to be those of consumers having "no preference" and are compared with the response frequencies elicited by a target pair, to determine whether the target pair elicits significant preferences. The primary goal of this paper was to study the robustness of 2 new so called disruptive protocols that reduced the proportion of consumers, who reported preferences when assessing a putatively identical pair of products. For this task, the tests were performed in a different language, in a different country, using different products from before. The results showed that the proportion of consumers reporting preferences for the placebo pair was reduced, confirming earlier work. Also, comparison of d' values showed a lack of significant overall differences between the placebo and target pairs, while chi-squared analyses indicated significant differences in the response frequencies. This indicated that the sample was segmented into 2 balanced groups with opposing preferences. © 2016 Institute of Food Technologists®

  6. An Improved Neutron Transport Algorithm for Space Radiation

    NASA Technical Reports Server (NTRS)

    Heinbockel, John H.; Clowdsley, Martha S.; Wilson, John W.

    2000-01-01

    A low-energy neutron transport algorithm for use in space radiation protection is developed. The algorithm is based upon a multigroup analysis of the straight-ahead Boltzmann equation by using a mean value theorem for integrals. This analysis is accomplished by solving a realistic but simplified neutron transport test problem. The test problem is analyzed by using numerical and analytical procedures to obtain an accurate solution within specified error bounds. Results from the test problem are then used for determining mean values associated with rescattering terms that are associated with a multigroup solution of the straight-ahead Boltzmann equation. The algorithm is then coupled to the Langley HZETRN code through the evaporation source term. Evaluation of the neutron fluence generated by the solar particle event of February 23, 1956, for a water and an aluminum-water shield-target configuration is then compared with LAHET and MCNPX Monte Carlo code calculations for the same shield-target configuration. The algorithm developed showed a great improvement in results over the unmodified HZETRN solution. In addition, a two-directional solution of the evaporation source showed even further improvement of the fluence near the front of the water target where diffusion from the front surface is important.

  7. Oligonucleotide-based strategies to combat polyglutamine diseases

    PubMed Central

    Fiszer, Agnieszka; Krzyzosiak, Wlodzimierz J.

    2014-01-01

    Considerable advances have been recently made in understanding the molecular aspects of pathogenesis and in developing therapeutic approaches for polyglutamine (polyQ) diseases. Studies on pathogenic mechanisms have extended our knowledge of mutant protein toxicity, confirmed the toxicity of mutant transcript and identified other toxic RNA and protein entities. One very promising therapeutic strategy is targeting the causative gene expression with oligonucleotide (ON) based tools. This straightforward approach aimed at halting the early steps in the cascade of pathogenic events has been widely tested for Huntington's disease and spinocerebellar ataxia type 3. In this review, we gather information on the use of antisense oligonucleotides and RNA interference triggers for the experimental treatment of polyQ diseases in cellular and animal models. We present studies testing non-allele-selective and allele-selective gene silencing strategies. The latter include targeting SNP variants associated with mutations or targeting the pathologically expanded CAG repeat directly. We compare gene silencing effectors of various types in a number of aspects, including their design, efficiency in cell culture experiments and pre-clinical testing. We discuss advantages, current limitations and perspectives of various ON-based strategies used to treat polyQ diseases. PMID:24848018

  8. Evaluation of Mean Glandular Dose and Modulation Transfer Function for Different Tube Potentials and Target-Filter Combinations in Computed Radiography Mammography

    PubMed Central

    Abdul Aziz,, Siti Aishah; Mohd Saparudin, Abdul Khaliq; Harun, Ahmad Zaky

    2013-01-01

    Background: Different target-filter combinations in computed radiography have different impacts on the dose and image quality in digital radiography. This study aims to evaluate the mean glandular dose (MGD) and modulation transfer function (MTF) of various target-filter combinations by investigating the signal intensities of X-ray beams. Methods: General Electric (GE) Senographe DMR Plus mammography unit was used for MGD and MTF evaluation. The measured MGD was compared with the dose reference level (DRL), whereas the MTF was evaluated using ImageJ 1.46o software. A modified Mammography Accreditation Phantom RMI 156 was exposed using different target-filter combinations of molybdenum-molybdenum (Mo-Mo), molybdenum-rhodium (Mo-Rh) and rhodium-rhodium (Rh-Rh) at two different tube voltages, 26 kV and 32 kV with 50 mAs. Results: In the MGD evaluations, all target-filters gave an MGD value of < 1.5 mGy. The one-way ANOVA test showed a highly significant interaction between the MGD and the kilovoltage and target-filter material used (26 kV: F (2,12) = 49,234, P = 0.001;32 kV: F (2,12) = 89,972, P = 0.001). A Tukey post-hoc test revealed that the MGD for 26 kV and 32 kV was highly affected by the target-filter combinations. The test of homogeneity of variances indicates that the MGD varies significantly for 26 kV and 32 kV images (0.045 and 0.030 (P < 0.05), respectively). However, the one-way ANOVA for the MTF shows that no significant difference exists between the target-filter combinations used with 26 kV and 32 kV images either in parallel or perpendicular to the chest wall side F (2,189) = 0.26, P > 0.05). Conclusion: Higher tube voltage and atomic number target-filter yield higher MGD values. However, the MTF is independent of the X-ray energy and the type of target-filter combinations used. PMID:23966821

  9. TargetM6A: Identifying N6-Methyladenosine Sites From RNA Sequences via Position-Specific Nucleotide Propensities and a Support Vector Machine.

    PubMed

    Li, Guang-Qing; Liu, Zi; Shen, Hong-Bin; Yu, Dong-Jun

    2016-10-01

    As one of the most ubiquitous post-transcriptional modifications of RNA, N 6 -methyladenosine ( [Formula: see text]) plays an essential role in many vital biological processes. The identification of [Formula: see text] sites in RNAs is significantly important for both basic biomedical research and practical drug development. In this study, we designed a computational-based method, called TargetM6A, to rapidly and accurately target [Formula: see text] sites solely from the primary RNA sequences. Two new features, i.e., position-specific nucleotide/dinucleotide propensities (PSNP/PSDP), are introduced and combined with the traditional nucleotide composition (NC) feature to formulate RNA sequences. The extracted features are further optimized to obtain a much more compact and discriminative feature subset by applying an incremental feature selection (IFS) procedure. Based on the optimized feature subset, we trained TargetM6A on the training dataset with a support vector machine (SVM) as the prediction engine. We compared the proposed TargetM6A method with existing methods for predicting [Formula: see text] sites by performing stringent jackknife tests and independent validation tests on benchmark datasets. The experimental results show that the proposed TargetM6A method outperformed the existing methods for predicting [Formula: see text] sites and remarkably improved the prediction performances, with MCC = 0.526 and AUC = 0.818. We also provided a user-friendly web server for TargetM6A, which is publicly accessible for academic use at http://csbio.njust.edu.cn/bioinf/TargetM6A.

  10. Visual performance on detection tasks with double-targets of the same and different difficulty.

    PubMed

    Chan, Alan H S; Courtney, Alan J; Ma, C W

    2002-10-20

    This paper reports a study of measurement of horizontal visual sensitivity limits for 16 subjects in single-target and double-targets detection tasks. Two phases of tests were conducted in the double-targets task; targets of the same difficulty were tested in phase one while targets of different difficulty were tested in phase two. The range of sensitivity for the double-targets test was found to be smaller than that for single-target in both the same and different target difficulty cases. The presence of another target was found to affect performance to a marked degree. Interference effect of the difficult target on detection of the easy one was greater than that of the easy one on the detection of the difficult one. Performance decrement was noted when correct percentage detection was plotted against eccentricity of target in both the single-target and double-targets tests. Nevertheless, the non-significant correlation found between the performance for the two tasks demonstrated that it was impossible to predict quantitatively ability for detection of double targets from the data for single targets. This indicated probable problems in generalizing data for single target visual lobes to those for multiple targets. Also lobe area values obtained from measurements using a single-target task cannot be applied in a mathematical model for situations with multiple occurrences of targets.

  11. Measurement of in-situ strength using projectile penetration: Tests of a new launching system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hearst, J.R.; Newmark, R.L.; Charest, J.A.

    1987-10-01

    The Lawrence Livermore National Laboratory has a continuing need to measure rock strength in situ, both for simple prediction of cavity size, and as input to computational models. In a previous report we compared two methods for measuring formation strength in situ: projectile penetration and a cone penetrometer. We determined that the projectile method was more promising for application to our large-diameter (2-4-m) hole environment. A major practical problem has been the development of a launcher and an apparatus for measuring depth of penetration that would be suitable for use in large-diameter holes. We are developing a gas-gun launcher systemmore » that will be capable of measuring both depth of penetration and deceleration of a reusable projectile. The current version of the launcher is trailer-mounted for testing at our Nevada Test Site (NTS) in tunnels and outcrops, but its design is such that it can be readily adapted for emplacement hole use. We test the current launcher on 60-cm cubes of gypsum cement, mixed to provie a range of densities (1.64 to 2.0 g/cc) and strengths (3 to 17 MPa). We compared depth of penetration of a 84-g projectile from a ''Betsy'' seismic gun - traveling on the order of 500 m/s - with the depth of penetration of a 13-kg projectile from the gas gun - traveling on the order of 30 m/s. For projectiles with the same nose size and shape, impacting targets of approximately constant strength, penetration depth was proportional to projectile kinetic energy. The ratio of kinetic energy to penetration depth was approximately proportional to target strength. Tests in tuffs with a wide range of strengths at NTS gave a similar linear relationship between the ratio of kinetic energy to penetration and target strength, and also a linear relationship between deceleration and strength. It appears that penetration can indeed be used as a semiquantitative measure of strength.« less

  12. Combating Drug Abuse by Targeting Toll-Like Receptor 4 (TLR4)

    DTIC Science & Technology

    2014-10-01

    area code )       Table  of  Contents...to  IACUC/OLAW   code .    In  the  meantime,  we  attempted  to  set  up  the  CPP  testing  paradigm  in   a...We   believe  this  is  due  to  the  comparative  increase  in  activity  (nearby  testing,   surgery ,  and  wet

  13. Randomized controlled trial of a messaging intervention to increase fruit and vegetable intake in adolescents: Affective versus instrumental messages.

    PubMed

    Carfora, Valentina; Caso, Daniela; Conner, Mark

    2016-11-01

    The present research aimed to test the efficacy of affective and instrumental text messages compared with a no-message control as a strategy to increase fruit and vegetable intake (FVI) in adolescents. A randomized controlled trial was used test impact of different text messages compared with no message on FVI over a 2-week period. A total of 1,065 adolescents (14-19 years) from a high school of the South of Italy completed the baseline questionnaire and were randomly allocated to one of three conditions: instrumental messages (N = 238), affective messages (N = 300), and no messages (N = 521). Students in the message conditions received one message each day over a 2-week period. The messages targeted affective (affective benefits) or instrumental (instrumental benefits) information about FVI. Self-reported FVI at 2 weeks was the key dependent variable. Analyses were based on the N = 634 who completed all aspects of the study. Findings showed that messages significantly increased FVI, particularly in the affective condition and this effect was partially mediated by changes in affective attitude and intentions towards FVI. Text messages can be used to increase FVI in adolescents. Text messages based on affective benefits are more effective than text messages based on instrumental benefits. Statement of contribution What is already known on this subject? Text messages have been shown to promote positive change in health behaviours. However, the most appropriate target for such text messages is less clear although targeting attitudes may be effective. What does this study add? This randomized controlled study shows that text messages targeting instrumental or affective attitudes produce changes in fruit and vegetable intake (FVI) in adolescents. Text messages targeting affective attitudes are shown to be more effective than text messages targeting instrumental attitudes. The effect of affective text messages on FVI was partially mediated by changes in affective attitudes. © 2016 The British Psychological Society.

  14. Contamination and UV ageing of diffuser targets used in satellite inflight and ground reference test site calibrations

    NASA Astrophysics Data System (ADS)

    Vaskuri, Anna; Greenwell, Claire; Hessey, Isabel; Tompkins, Jordan; Woolliams, Emma

    2018-02-01

    Diffuser reflectance targets are key components in in-orbit calibrations and for verifying ground reference test sites. In this work, Spectralon, Diffusil, and Heraeus diffusers were exposed to exhaust gases and ultraviolet (UV) radiation in the ambient air conditions and their degradations were monitored by measuring changes in spectral reflectances. Spectralon is a state-of-the-art diffuser made of polytetrafluoroethylene, and Diffusil and Heraeus diffusers are made of fused silica with gas bubbles inside. Based on the contamination tests, Spectralon degrades faster than fused silica diffusers. For the samples exposed to contamination for 20 minutes, the 250 nm - 400 nm total diffuse spectral reflectance of Spectralon degraded 3-5 times more when exposed to petrol-like emission and 16-23 times more when exposed to diesel-like emission, compared with Diffusil. When the reflectance changes of Spectralon were compared with those of Heraeus, Spectralon degraded 3-4 times more when exposed to petrol-like emission for 20 minutes and 5-7 times more when exposed to diesel-like emission for 7.5 minutes. When the samples contaminated were exposed to UV radiation in the ambient air, their reflectance gradually restored back to the original level. In conclusion, fused silica diffusers are more resistant to hydrocarbon contaminants present in ground reference test sites, and thus more stable under UV radiation in the air.

  15. Targeted left ventricular lead placement to guide cardiac resynchronization therapy: the TARGET study: a randomized, controlled trial.

    PubMed

    Khan, Fakhar Z; Virdee, Mumohan S; Palmer, Christopher R; Pugh, Peter J; O'Halloran, Denis; Elsik, Maros; Read, Philip A; Begley, David; Fynn, Simon P; Dutka, David P

    2012-04-24

    This study sought to assess the impact of targeted left ventricular (LV) lead placement on outcomes of cardiac resynchronization therapy (CRT). Placement of the LV lead to the latest sites of contraction and away from the scar confers the best response to CRT. We conducted a randomized, controlled trial to compare a targeted approach to LV lead placement with usual care. A total of 220 patients scheduled for CRT underwent baseline echocardiographic speckle-tracking 2-dimensional radial strain imaging and were then randomized 1:1 into 2 groups. In group 1 (TARGET [Targeted Left Ventricular Lead Placement to Guide Cardiac Resynchronization Therapy]), the LV lead was positioned at the latest site of peak contraction with an amplitude of >10% to signify freedom from scar. In group 2 (control) patients underwent standard unguided CRT. Patients were classified by the relationship of the LV lead to the optimal site as concordant (at optimal site), adjacent (within 1 segment), or remote (≥2 segments away). The primary endpoint was a ≥15% reduction in LV end-systolic volume at 6 months. Secondary endpoints were clinical response (≥1 improvement in New York Heart Association functional class), all-cause mortality, and combined all-cause mortality and heart failure-related hospitalization. The groups were balanced at randomization. In the TARGET group, there was a greater proportion of responders at 6 months (70% vs. 55%, p = 0.031), giving an absolute difference in the primary endpoint of 15% (95% confidence interval: 2% to 28%). Compared with controls, TARGET patients had a higher clinical response (83% vs. 65%, p = 0.003) and lower rates of the combined endpoint (log-rank test, p = 0.031). Compared with standard CRT treatment, the use of speckle-tracking echocardiography to the target LV lead placement yields significantly improved response and clinical status and lower rates of combined death and heart failure-related hospitalization. (Targeted Left Ventricular Lead Placement to Guide Cardiac Resynchronization Therapy [TARGET] study); ISRCTN19717943). Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. Assessment of biochemical mechanisms of tolerance to chlorpyrifos in ancient and contemporary Daphnia pulicaria genotypes.

    PubMed

    Simpson, Adam M; Jeyasingh, Punidan D; Belden, Jason B

    2017-12-01

    The evolution of tolerance to environmental contaminants in non-target taxa has been largely studied by comparing extant populations experiencing contrasting exposure. Previous research has demonstrated that "resurrected" genotypes from a population of Daphnia pulicaria express temporal variation in sensitivity to the insecticide chlorpyrifos. Ancient genotypes (1301-1646AD.) were on average more sensitive to this chemical compared to the contemporary genotypes (1967-1977AD.). To determine the physiological mechanisms of tolerance, a series of biochemical assays was performed on three ancient and three contemporary genotypes; these six genotypes exhibited the most sensitive and most tolerant phenotypes within the population, respectively. Metabolic tolerance mechanisms were evaluated using acute toxicity testing, while target-site tolerance was assessed via in vitro acetylcholinesterase (AChE) assays. Acute toxicity tests were conducted using i) the toxic metabolite chlorpyrifos-oxon (CPF-oxon) and ii) CPF-oxon co-applied with piperonyl butoxide (PBO), a known Phase-I metabolic inhibitor. Both series of toxicity tests reduced the mean variation in sensitivity between tolerant and sensitive genotypes. Exposure to CPF-O reduced the disparity from a 4.7-fold to 1.6-fold difference in sensitivity. The addition of PBO further reduced the variation to a 1.2-fold difference in sensitivity. In vitro acetylcholinesterase assays yielded no significant differences in constitutive activity or target-site sensitivity. These findings suggest that pathways involving Phase-I detoxification and/or bioactivation of chlorpyrifos play a significant role in dictating the microevolutionary trajectories of tolerance in this population. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Improved target detection by IR dual-band image fusion

    NASA Astrophysics Data System (ADS)

    Adomeit, U.; Ebert, R.

    2009-09-01

    Dual-band thermal imagers acquire information simultaneously in both the 8-12 μm (long-wave infrared, LWIR) and the 3-5 μm (mid-wave infrared, MWIR) spectral range. Compared to single-band thermal imagers they are expected to have several advantages in military applications. These advantages include the opportunity to use the best band for given atmospheric conditions (e. g. cold climate: LWIR, hot and humid climate: MWIR), the potential to better detect camouflaged targets and an improved discrimination between targets and decoys. Most of these advantages have not yet been verified and/or quantified. It is expected that image fusion allows better exploitation of the information content available with dual-band imagers especially with respect to detection of targets. We have developed a method for dual-band image fusion based on the apparent temperature differences in the two bands. This method showed promising results in laboratory tests. In order to evaluate its performance under operational conditions we conducted a field trial in an area with high thermal clutter. In such areas, targets are hardly to detect in single-band images because they vanish in the clutter structure. The image data collected in this field trial was used for a perception experiment. This perception experiment showed an enhanced target detection range and reduced false alarm rate for the fused images compared to the single-band images.

  18. Marine Targets Detection in Pol-SAR Data

    NASA Astrophysics Data System (ADS)

    Chen, Peng; Yang, Jingsong

    2016-08-01

    In this poster, we present a new method of marine target detection in Pol-SAR data. One band SAR image, like HH, VV or VH, can be used to find marine target using a Contant False Alarm Ratio (CFAR) algorithm. But some false detection may happen, as the sidelobe of antenna, Azimuth ambiguity, strong speckle noise and so on in the single band SAR image. Pol-SAR image can get more information of targets. After decomposition and false color composite, the sidelobe of antenna and Azimuth ambiguity could be deleted. So, the method presented include three steps, decomposion, false color composite and supervised classification. The result of Radarsat-2 SAR image test indicates a good accuracy. The detection results are compared with Automatic Indentify Sistem (AIS) data, the accuracy of right detection is above 95% and false detection ratio is below 5%.

  19. Sequential sensory and decision processing in posterior parietal cortex

    PubMed Central

    Ibos, Guilhem; Freedman, David J

    2017-01-01

    Decisions about the behavioral significance of sensory stimuli often require comparing sensory inference of what we are looking at to internal models of what we are looking for. Here, we test how neuronal selectivity for visual features is transformed into decision-related signals in posterior parietal cortex (area LIP). Monkeys performed a visual matching task that required them to detect target stimuli composed of conjunctions of color and motion-direction. Neuronal recordings from area LIP revealed two main findings. First, the sequential processing of visual features and the selection of target-stimuli suggest that LIP is involved in transforming sensory information into decision-related signals. Second, the patterns of color and motion selectivity and their impact on decision-related encoding suggest that LIP plays a role in detecting target stimuli by comparing bottom-up sensory inputs (what the monkeys were looking at) and top-down cognitive encoding inputs (what the monkeys were looking for). DOI: http://dx.doi.org/10.7554/eLife.23743.001 PMID:28418332

  20. Generalization of Dynamics Learning Across Changes in Movement Amplitude

    PubMed Central

    Mattar, Andrew A. G.

    2010-01-01

    Studies on generalization show the nature of how learning is encoded in the brain. Previous studies have shown rather limited generalization of dynamics learning across changes in movement direction, a finding that is consistent with the idea that learning is primarily local. In contrast, studies show a broader pattern of generalization across changes in movement amplitude, suggesting a more general form of learning. To understand this difference, we performed an experiment in which subjects held a robotic manipulandum and made movements to targets along the body midline. Subjects were trained in a velocity-dependent force field while moving to a 15 cm target. After training, subjects were tested for generalization using movements to a 30 cm target. We used force channels in conjunction with movements to the 30 cm target to assess the extent of generalization. Force channels restricted lateral movements and allowed us to measure force production during generalization. We compared actual lateral forces to the forces expected if dynamics learning generalized fully. We found that, during the test for generalization, subjects produced reliably less force than expected. Force production was appropriate for the portion of the transfer movement in which velocities corresponded to those experienced with the 15 cm target. Subjects failed to produce the expected forces when velocities exceeded those experienced in the training task. This suggests that dynamics learning generalizes little beyond the range of one's experience. Consistent with this result, subjects who trained on the 30 cm target showed full generalization to the 15 cm target. We performed two additional experiments that show that interleaved trials to the 30 cm target during training on the 15 cm target can resolve the difference between the current results and those reported previously. PMID:20463200

  1. RobOKoD: microbial strain design for (over)production of target compounds.

    PubMed

    Stanford, Natalie J; Millard, Pierre; Swainston, Neil

    2015-01-01

    Sustainable production of target compounds such as biofuels and high-value chemicals for pharmaceutical, agrochemical, and chemical industries is becoming an increasing priority given their current dependency upon diminishing petrochemical resources. Designing these strains is difficult, with current methods focusing primarily on knocking-out genes, dismissing other vital steps of strain design including the overexpression and dampening of genes. The design predictions from current methods also do not translate well-into successful strains in the laboratory. Here, we introduce RobOKoD (Robust, Overexpression, Knockout and Dampening), a method for predicting strain designs for overproduction of targets. The method uses flux variability analysis to profile each reaction within the system under differing production percentages of target-compound and biomass. Using these profiles, reactions are identified as potential knockout, overexpression, or dampening targets. The identified reactions are ranked according to their suitability, providing flexibility in strain design for users. The software was tested by designing a butanol-producing Escherichia coli strain, and was compared against the popular OptKnock and RobustKnock methods. RobOKoD shows favorable design predictions, when predictions from these methods are compared to a successful butanol-producing experimentally-validated strain. Overall RobOKoD provides users with rankings of predicted beneficial genetic interventions with which to support optimized strain design.

  2. RobOKoD: microbial strain design for (over)production of target compounds

    PubMed Central

    Stanford, Natalie J.; Millard, Pierre; Swainston, Neil

    2015-01-01

    Sustainable production of target compounds such as biofuels and high-value chemicals for pharmaceutical, agrochemical, and chemical industries is becoming an increasing priority given their current dependency upon diminishing petrochemical resources. Designing these strains is difficult, with current methods focusing primarily on knocking-out genes, dismissing other vital steps of strain design including the overexpression and dampening of genes. The design predictions from current methods also do not translate well-into successful strains in the laboratory. Here, we introduce RobOKoD (Robust, Overexpression, Knockout and Dampening), a method for predicting strain designs for overproduction of targets. The method uses flux variability analysis to profile each reaction within the system under differing production percentages of target-compound and biomass. Using these profiles, reactions are identified as potential knockout, overexpression, or dampening targets. The identified reactions are ranked according to their suitability, providing flexibility in strain design for users. The software was tested by designing a butanol-producing Escherichia coli strain, and was compared against the popular OptKnock and RobustKnock methods. RobOKoD shows favorable design predictions, when predictions from these methods are compared to a successful butanol-producing experimentally-validated strain. Overall RobOKoD provides users with rankings of predicted beneficial genetic interventions with which to support optimized strain design. PMID:25853130

  3. Targets of drugs are generally, and targets of drugs having side effects are specifically good spreaders of human interactome perturbations.

    PubMed

    Perez-Lopez, Áron R; Szalay, Kristóf Z; Türei, Dénes; Módos, Dezső; Lenti, Katalin; Korcsmáros, Tamás; Csermely, Peter

    2015-05-11

    Network-based methods are playing an increasingly important role in drug design. Our main question in this paper was whether the efficiency of drug target proteins to spread perturbations in the human interactome is larger if the binding drugs have side effects, as compared to those which have no reported side effects. Our results showed that in general, drug targets were better spreaders of perturbations than non-target proteins, and in particular, targets of drugs with side effects were also better spreaders of perturbations than targets of drugs having no reported side effects in human protein-protein interaction networks. Colorectal cancer-related proteins were good spreaders and had a high centrality, while type 2 diabetes-related proteins showed an average spreading efficiency and had an average centrality in the human interactome. Moreover, the interactome-distance between drug targets and disease-related proteins was higher in diabetes than in colorectal cancer. Our results may help a better understanding of the network position and dynamics of drug targets and disease-related proteins, and may contribute to develop additional, network-based tests to increase the potential safety of drug candidates.

  4. Targets of drugs are generally, and targets of drugs having side effects are specifically good spreaders of human interactome perturbations

    NASA Astrophysics Data System (ADS)

    Perez-Lopez, Áron R.; Szalay, Kristóf Z.; Türei, Dénes; Módos, Dezső; Lenti, Katalin; Korcsmáros, Tamás; Csermely, Peter

    2015-05-01

    Network-based methods are playing an increasingly important role in drug design. Our main question in this paper was whether the efficiency of drug target proteins to spread perturbations in the human interactome is larger if the binding drugs have side effects, as compared to those which have no reported side effects. Our results showed that in general, drug targets were better spreaders of perturbations than non-target proteins, and in particular, targets of drugs with side effects were also better spreaders of perturbations than targets of drugs having no reported side effects in human protein-protein interaction networks. Colorectal cancer-related proteins were good spreaders and had a high centrality, while type 2 diabetes-related proteins showed an average spreading efficiency and had an average centrality in the human interactome. Moreover, the interactome-distance between drug targets and disease-related proteins was higher in diabetes than in colorectal cancer. Our results may help a better understanding of the network position and dynamics of drug targets and disease-related proteins, and may contribute to develop additional, network-based tests to increase the potential safety of drug candidates.

  5. Targets of drugs are generally, and targets of drugs having side effects are specifically good spreaders of human interactome perturbations

    PubMed Central

    Perez-Lopez, Áron R.; Szalay, Kristóf Z.; Türei, Dénes; Módos, Dezső; Lenti, Katalin; Korcsmáros, Tamás; Csermely, Peter

    2015-01-01

    Network-based methods are playing an increasingly important role in drug design. Our main question in this paper was whether the efficiency of drug target proteins to spread perturbations in the human interactome is larger if the binding drugs have side effects, as compared to those which have no reported side effects. Our results showed that in general, drug targets were better spreaders of perturbations than non-target proteins, and in particular, targets of drugs with side effects were also better spreaders of perturbations than targets of drugs having no reported side effects in human protein-protein interaction networks. Colorectal cancer-related proteins were good spreaders and had a high centrality, while type 2 diabetes-related proteins showed an average spreading efficiency and had an average centrality in the human interactome. Moreover, the interactome-distance between drug targets and disease-related proteins was higher in diabetes than in colorectal cancer. Our results may help a better understanding of the network position and dynamics of drug targets and disease-related proteins, and may contribute to develop additional, network-based tests to increase the potential safety of drug candidates. PMID:25960144

  6. A difference tracking algorithm based on discrete sine transform

    NASA Astrophysics Data System (ADS)

    Liu, HaoPeng; Yao, Yong; Lei, HeBing; Wu, HaoKun

    2018-04-01

    Target tracking is an important field of computer vision. The template matching tracking algorithm based on squared difference matching (SSD) and standard correlation coefficient (NCC) matching is very sensitive to the gray change of image. When the brightness or gray change, the tracking algorithm will be affected by high-frequency information. Tracking accuracy is reduced, resulting in loss of tracking target. In this paper, a differential tracking algorithm based on discrete sine transform is proposed to reduce the influence of image gray or brightness change. The algorithm that combines the discrete sine transform and the difference algorithm maps the target image into a image digital sequence. The Kalman filter predicts the target position. Using the Hamming distance determines the degree of similarity between the target and the template. The window closest to the template is determined the target to be tracked. The target to be tracked updates the template. Based on the above achieve target tracking. The algorithm is tested in this paper. Compared with SSD and NCC template matching algorithms, the algorithm tracks target stably when image gray or brightness change. And the tracking speed can meet the read-time requirement.

  7. Here Today, Gone Tomorrow – Adaptation to Change in Memory-Guided Visual Search

    PubMed Central

    Zellin, Martina; Conci, Markus; von Mühlenen, Adrian; Müller, Hermann J.

    2013-01-01

    Visual search for a target object can be facilitated by the repeated presentation of an invariant configuration of nontargets (‘contextual cueing’). Here, we tested adaptation of learned contextual associations after a sudden, but permanent, relocation of the target. After an initial learning phase targets were relocated within their invariant contexts and repeatedly presented at new locations, before they returned to the initial locations. Contextual cueing for relocated targets was neither observed after numerous presentations nor after insertion of an overnight break. Further experiments investigated whether learning of additional, previously unseen context-target configurations is comparable to adaptation of existing contextual associations to change. In contrast to the lack of adaptation to changed target locations, contextual cueing developed for additional invariant configurations under identical training conditions. Moreover, across all experiments, presenting relocated targets or additional contexts did not interfere with contextual cueing of initially learned invariant configurations. Overall, the adaptation of contextual memory to changed target locations was severely constrained and unsuccessful in comparison to learning of an additional set of contexts, which suggests that contextual cueing facilitates search for only one repeated target location. PMID:23555038

  8. Prostate-Specific Membrane Antigen-Targeted Site-Directed Antibody-Conjugated Apoferritin Nanovehicle Favorably Influences In Vivo Side Effects of Doxorubicin.

    PubMed

    Dostalova, Simona; Polanska, Hana; Svobodova, Marketa; Balvan, Jan; Krystofova, Olga; Haddad, Yazan; Krizkova, Sona; Masarik, Michal; Eckschlager, Tomas; Stiborova, Marie; Heger, Zbynek; Adam, Vojtech

    2018-06-11

    Herein, we describe the in vivo effects of doxorubicin (DOX) encapsulated in ubiquitous protein apoferritin (APO) and its efficiency and safety in anti-tumor treatment. APODOX is both passively (through Enhanced Permeability and Retention effect) and actively targeted to tumors through prostate-specific membrane antigen (PSMA) via mouse antibodies conjugated to the surface of horse spleen APO. To achieve site-directed conjugation of the antibodies, a HWRGWVC heptapeptide linker was used. The prostate cancer-targeted and non-targeted nanocarriers were tested using subcutaneously implanted LNCaP cells in athymic mice models, and compared to free DOX. Prostate cancer-targeted APODOX retained the high potency of DOX in attenuation of tumors (with 55% decrease in tumor volume after 3 weeks of treatment). DOX and non-targeted APODOX treatment caused damage to liver, kidney and heart tissues. In contrast, no elevation in liver or kidney enzymes and negligible changes were revealed by histological assessment in prostate cancer-targeted APODOX-treated mice. Overall, we show that the APO nanocarrier provides an easy encapsulation protocol, reliable targeting, high therapeutic efficiency and very low off-target toxicity, and is thus a promising delivery system for translation into clinical use.

  9. Impact of Spot Size and Spacing on the Quality of Robustly Optimized Intensity Modulated Proton Therapy Plans for Lung Cancer.

    PubMed

    Liu, Chenbin; Schild, Steven E; Chang, Joe Y; Liao, Zhongxing; Korte, Shawn; Shen, Jiajian; Ding, Xiaoning; Hu, Yanle; Kang, Yixiu; Keole, Sameer R; Sio, Terence T; Wong, William W; Sahoo, Narayan; Bues, Martin; Liu, Wei

    2018-06-01

    To investigate how spot size and spacing affect plan quality, robustness, and interplay effects of robustly optimized intensity modulated proton therapy (IMPT) for lung cancer. Two robustly optimized IMPT plans were created for 10 lung cancer patients: first by a large-spot machine with in-air energy-dependent large spot size at isocenter (σ: 6-15 mm) and spacing (1.3 σ), and second by a small-spot machine with in-air energy-dependent small spot size (σ: 2-6 mm) and spacing (5 mm). Both plans were generated by optimizing radiation dose to internal target volume on averaged 4-dimensional computed tomography scans using an in-house-developed IMPT planning system. The dose-volume histograms band method was used to evaluate plan robustness. Dose evaluation software was developed to model time-dependent spot delivery to incorporate interplay effects with randomized starting phases for each field per fraction. Patient anatomy voxels were mapped phase-to-phase via deformable image registration, and doses were scored using in-house-developed software. Dose-volume histogram indices, including internal target volume dose coverage, homogeneity, and organs at risk (OARs) sparing, were compared using the Wilcoxon signed-rank test. Compared with the large-spot machine, the small-spot machine resulted in significantly lower heart and esophagus mean doses, with comparable target dose coverage, homogeneity, and protection of other OARs. Plan robustness was comparable for targets and most OARs. With interplay effects considered, significantly lower heart and esophagus mean doses with comparable target dose coverage and homogeneity were observed using smaller spots. Robust optimization with a small spot-machine significantly improves heart and esophagus sparing, with comparable plan robustness and interplay effects compared with robust optimization with a large-spot machine. A small-spot machine uses a larger number of spots to cover the same tumors compared with a large-spot machine, which gives the planning system more freedom to compensate for the higher sensitivity to uncertainties and interplay effects for lung cancer treatments. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Sentence Reading and Writing for Second Language Vocabulary Acquisition

    ERIC Educational Resources Information Center

    Pichette, Francois; de Serres, Linda; Lafontaine, Marc

    2012-01-01

    This study compares the relative effectiveness of reading and writing sentences for the incidental acquisition of new vocabulary in a second language. It also examines if recall varies according to the concreteness of target words. Participants were 203 French-speaking intermediate and advanced English as second language (ESL) learners, tested for…

  11. A Randomized, Controlled Trial of Meditation Compared to Exposure Therapy and Education Control on PTSD in Veterans

    DTIC Science & Technology

    2016-10-01

    baseline testing, were randomized (approximately 18% female; mean age= 48). Three-month posttesting compliance is approximately 83%. Task 6...April, 2016 to review the progress of the study. • As of Sept 30, 2016, 200 subjects have been recruited (210 target). Posttest compliance is >80

  12. HS-SPME-GC-MS analysis of body odor to test the efficacy of foot deodorant formulations.

    PubMed

    Caroprese, Alessandro; Gabbanini, Simone; Beltramini, Claudia; Lucchi, Elena; Valgimigli, Luca

    2009-11-01

    Foot malodor is mostly due to short-chain fatty acids produced by bacterial metabolism of eccrine sweating. We aimed to develop a protocol for an objective (instrumental) efficacy evaluation of foot deodorant formulations. Head-space solid-phase microextractions of target fatty acids from the feet of six healthy volunteers were analyzed by GC-MS. A comparative analysis of the treated vs. the untreated foot was performed in each subject after washing the feet with a physiologic solution and incubating at 36 degrees C for 24-72 h in tryptic soy agar growth medium. Acetic, butyric, isobutyric and isovaleric acids were identified as the main contributors to foot malodor in the majority of volunteers. Propionic, valeric and isocaproic acids were also detected in some subjects. Comparative analysis according to the protocol developed showed a statistically significant (P<0.01) reduction of target fatty acids ranging from -26.6% to -77.0%. The protocol developed is a convenient, sensitive and non-invasive method to test the efficacy of foot deodorant formulations in human volunteers.

  13. Rapid computational identification of the targets of protein kinase inhibitors.

    PubMed

    Rockey, William M; Elcock, Adrian H

    2005-06-16

    We describe a method for rapidly computing the relative affinities of an inhibitor for all individual members of a family of homologous receptors. The approach, implemented in a new program, SCR, models inhibitor-receptor interactions in full atomic detail with an empirical energy function and includes an explicit account of flexibility in homology-modeled receptors through sampling of libraries of side chain rotamers. SCR's general utility was demonstrated by application to seven different protein kinase inhibitors: for each inhibitor, relative binding affinities with panels of approximately 20 protein kinases were computed and compared with experimental data. For five of the inhibitors (SB203580, purvalanol B, imatinib, H89, and hymenialdisine), SCR provided excellent reproduction of the experimental trends and, importantly, was capable of identifying the targets of inhibitors even when they belonged to different kinase families. The method's performance in a predictive setting was demonstrated by performing separate training and testing applications, and its key assumptions were tested by comparison with a number of alternative approaches employing the ligand-docking program AutoDock (Morris et al. J. Comput. Chem. 1998, 19, 1639-1662). These comparison tests included using AutoDock in nondocking and docking modes and performing energy minimizations of inhibitor-kinase complexes with the molecular mechanics code GROMACS (Berendsen et al. Comput. Phys. Commun. 1995, 91, 43-56). It was found that a surprisingly important aspect of SCR's approach is its assumption that the inhibitor be modeled in the same orientation for each kinase: although this assumption is in some respects unrealistic, calculations that used apparently more realistic approaches produced clearly inferior results. Finally, as a large-scale application of the method, SB203580, purvalanol B, and imatinib were screened against an almost full complement of 493 human protein kinases using SCR in order to identify potential new targets; the predicted targets of SB203580 were compared with those identified in recent proteomics-based experiments. These kinome-wide screens, performed within a day on a small cluster of PCs, indicate that explicit computation of inhibitor-receptor binding affinities has the potential to promote rapid discovery of new therapeutic targets for existing inhibitors.

  14. Flight control system design factors for applying automated testing techniques

    NASA Technical Reports Server (NTRS)

    Sitz, Joel R.; Vernon, Todd H.

    1990-01-01

    The principal design features and operational experiences of the X-29 forward-swept-wing aircraft and F-18 high alpha research vehicle (HARV) automated test systems are discussed. It is noted that operational experiences in developing and using these automated testing techniques have highlighted the need for incorporating target system features to improve testability. Improved target system testability can be accomplished with the addition of nonreal-time and real-time features. Online access to target system implementation details, unobtrusive real-time access to internal user-selectable variables, and proper software instrumentation are all desirable features of the target system. Also, test system and target system design issues must be addressed during the early stages of the target system development. Processing speeds of up to 20 million instructions/s and the development of high-bandwidth reflective memory systems have improved the ability to integrate the target system and test system for the application of automated testing techniques. It is concluded that new methods of designing testability into the target systems are required.

  15. Targeted HIV Screening in Eight Emergency Departments: The DICI-VIH Cluster-Randomized Two-Period Crossover Trial.

    PubMed

    Leblanc, Judith; Hejblum, Gilles; Costagliola, Dominique; Durand-Zaleski, Isabelle; Lert, France; de Truchis, Pierre; Verbeke, Geert; Rousseau, Alexandra; Piquet, Hélène; Simon, François; Pateron, Dominique; Simon, Tabassome; Crémieux, Anne-Claude

    2018-07-01

    This study compares the effectiveness and cost-effectiveness of nurse-driven targeted HIV screening alongside physician-directed diagnostic testing (intervention strategy) with diagnostic testing alone (control strategy) in 8 emergency departments. In this cluster-randomized, 2-period, crossover trial, 18- to 64-year-old patients presenting for reasons other than potential exposure to HIV were included. The strategy applied first was randomly assigned. During both periods, diagnostic testing was prescribed by physicians following usual care. During the intervention periods, patients were asked to complete a self-administered questionnaire. According to their answers, the triage nurse suggested performing a rapid test to patients belonging to a high-risk group. The primary outcome was the proportion of new diagnoses among included patients, which further refers to effectiveness. A secondary outcome was the intervention's incremental cost (health care system perspective) per additional diagnosis. During the intervention periods, 74,161 patients were included, 16,468 completed the questionnaire, 4,341 belonged to high-risk groups, and 2,818 were tested by nurses, yielding 13 new diagnoses. Combined with 9 diagnoses confirmed through 97 diagnostic tests, 22 new diagnoses were established. During the control periods, 74,166 patients were included, 92 were tested, and 6 received a new diagnosis. The proportion of new diagnoses among included patients was higher during the intervention than in the control periods (3.0 per 10,000 versus 0.8 per 10,000; difference 2.2 per 10,000, 95% CI 1.3 to 3.6; relative risk 3.7, 95% CI 1.4 to 9.8). The incremental cost was €1,324 per additional new diagnosis. The combined strategy of targeted screening and diagnostic testing was effective. Copyright © 2017 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  16. Evaluation and Acceptability of a Simplified Test of Visual Function at Birth in a Limited-Resource Setting.

    PubMed

    Carrara, Verena I; Darakomon, Mue Chae; Thin, Nant War War; Paw, Naw Ta Kaw; Wah, Naw; Wah, Hser Gay; Helen, Naw; Keereecharoen, Suporn; Paw, Naw Ta Mlar; Jittamala, Podjanee; Nosten, François H; Ricci, Daniela; McGready, Rose

    2016-01-01

    Neurological examination, including visual fixation and tracking of a target, is routinely performed in the Shoklo Malaria Research Unit postnatal care units on the Thailand-Myanmar border. We aimed to evaluate a simple visual newborn test developed in Italy and performed by non-specialized personnel working in neonatal care units. An intensive training of local health staff in Thailand was conducted prior to performing assessments at 24, 48 and 72 hours of life in healthy, low-risk term singletons. The 48 and 72 hours results were then compared to values obtained to those from Italy. Parents and staff administering the test reported on acceptability. One hundred and seventy nine newborns, between June 2011 and October 2012, participated in the study. The test was rapidly completed if the infant remained in an optimal behavioral stage (7 ± 2 minutes) but the test duration increased significantly (12 ± 4 minutes, p < 0.001) if its behavior changed. Infants were able to fix a target and to discriminate a colored face at 24 hours of life. Horizontal tracking of a target was achieved by 96% (152/159) of the infants at 48 hours. Circular tracking, stripe discrimination and attention to distance significantly improved between each 24-hour test period. The test was easily performed by non-specialized local staff and well accepted by the parents. Healthy term singletons in this limited-resource setting have a visual response similar to that obtained to gestational age matched newborns in Italy. It is possible to use these results as a reference set of values for the visual assessment in Karen and Burmese infants in the first 72 hours of life. The utility of the 24 hours test should be pursued.

  17. An innovative and highly drug-tolerant approach for detecting neutralizing antibodies directed to therapeutic antibodies.

    PubMed

    Sloan, John H; Conway, Richard G; Pottanat, Thomas G; Troutt, Jason S; Higgs, Richard E; Konrad, Robert J; Qian, Yue-Wei

    2016-10-01

    Immunogenicity testing of biotherapeutic drugs is a regulatory requirement. Herein, we describe a drug-tolerant assay for detecting neutralizing antibodies against a therapeutic antibody. Excess target of the therapeutic antibody was incorporated into the detection step of an affinity capture elution assay. Signal generated from binding of antidrug antibody (ADA) to the therapeutic antibody was compared with signal from binding of ADA to the therapeutic antibody preincubated with its target. The results demonstrated that the target blocked binding of the therapeutic antibody to neutralizing monkey ADA and to two anti-idiotypic antibodies. This highly drug-tolerant novel approach enables the detection of neutralizing antibodies and allows for one basic assay format to achieve complete characterization of ADA responses.

  18. Neighborhood diversity of potentially pathogenic bacteria in drinking water from the city of Maroua, Cameroon.

    PubMed

    Healy-Profitós, Jessica; Lee, Seungjun; Mouhaman, Arabi; Garabed, Rebecca; Moritz, Mark; Piperata, Barbara; Lee, Jiyoung

    2016-06-01

    This study examined the spatial variation of potential gastrointestinal pathogens within drinking water sources and home storage containers in four neighborhoods in Maroua, Cameroon. Samples were collected from source (n = 28) and home containers (n = 60) in each study neighborhood. Pathogen contamination was assessed using quantitative polymerase chain reaction, targeting Campylobacter spp., Shiga toxin producing Escherichia coli (virulence genes, stx1 and stx2), and Salmonella spp. Microbial source tracking (MST) targeted three different host-specific markers: HF183 (human), Rum2Bac (ruminant) and GFD (poultry) to identify contamination sources. Staphylococcus aureus and the tetracycline-resistance gene (tetQ) were assessed to measure human hand contact and presence of antibiotic-resistant bacteria. Pathogen/MST levels were compared statistically and spatially, and neighborhood variation was compared with previously collected demographic information. All the test fecal markers and pathogens (except Arcobacter) were detected in home and source samples. Two neighborhoods tested positive for most pathogens/MST while the others only tested positive for one or two. Spatial variation of pathogens/MST existed between sources, storage containers, and neighborhoods. Differing population density and ethno-economic characteristics could potentially explain variation. Future research should explore the influence of demographic and ethno-economic factors on water quality during microbial risk assessments in urban Africa.

  19. Where Do Female Sex Workers Seek HIV and Reproductive Health Care and What Motivates These Choices? A Survey in 4 Cities in India, Kenya, Mozambique and South Africa.

    PubMed

    Lafort, Yves; Greener, Ross; Roy, Anuradha; Greener, Letitia; Ombidi, Wilkister; Lessitala, Faustino; Haghparast-Bidgoli, Hassan; Beksinska, Mags; Gichangi, Peter; Reza-Paul, Sushena; Smit, Jenni A; Chersich, Matthew; Delva, Wim

    2016-01-01

    A baseline cross-sectional survey among female sex workers (FSWs) was conducted in four cities within the context of an implementation research project aiming to improve FSWs' access to HIV, and sexual and reproductive health (SRH) services. The survey measured where FSWs seek HIV/SRH care and what motivates their choice. Using respondent-driven sampling (RDS), FWSs were recruited in Durban, South Africa (n = 400), Tete, Mozambique (n = 308), Mombasa, Kenya (n = 400) and Mysore, India (n = 458) and interviewed. RDS-adjusted proportions were estimated by non-parametric bootstrapping, and compared across cities using post-hoc pairwise comparison tests. Across cities, FSWs most commonly sought care for the majority of HIV/SRH services at public health facilities, most especially in Durban (ranging from 65% for condoms to 97% for HIV care). Services specifically targeting FSWs only had a high coverage in Mysore for STI care (89%) and HIV testing (79%). Private-for-profit clinics were important providers in Mombasa (ranging from 17% for STI care and HIV testing to 43% for HIV care), but not in the other cities. The most important reason for the choice of care provider in Durban and Mombasa was proximity, in Tete 'where they always go', and in Mysore cost of care. Where available, clinics specifically targeting FSWs were more often chosen because of shorter waiting times, perceived higher quality of care, more privacy and friendlier personnel. The place where care is sought for HIV/SRH services differs substantially between cities. Targeted services have limited coverage in the African cities compared to Mysore. Convenience appears more important for choosing the place of care than aspects of quality of care. The best model to improve access, linking targeted interventions with general health services, will need to be tailored to the specific context of each city.

  20. Voluntary Control of Residual Antagonistic Muscles in Transtibial Amputees: Feedforward Ballistic Contractions and Implications for Direct Neural Control of Powered Lower Limb Prostheses.

    PubMed

    Huang, Stephanie; Huang, He

    2018-04-01

    Discrete, rapid (i.e., ballistic like) muscle activation patterns have been observed in ankle muscles (i.e., plantar flexors and dorsiflexors) of able-bodied individuals during voluntary posture control. This observation motivated us to investigate whether transtibial amputees are capable of generating such a ballistic-like activation pattern accurately using their residual ankle muscles in order to assess whether the volitional postural control of a powered ankle prosthesis using proportional myoelectric control via residual muscles could be feasible. In this paper, we asked ten transtibial amputees to generate ballistic-like activation patterns using their residual lateral gastrocnemius and residual tibialis anterior to control a computer cursor via proportional myoelectric control to hit targets positioned at 20% and 40% of maximum voluntary contraction of the corresponding residual muscle. During practice conditions, we asked amputees to hit a single target repeatedly. During testing conditions, we asked amputees to hit a random sequence of targets. We compared movement time to target and end-point accuracy. We also examined motor recruitment synchronization via time-frequency representations of residual muscle activation. The result showed that median end-point error ranged from -0.6% to 1% maximum voluntary contraction across subjects during practice, which was significantly lower compared to testing ( ). Average movement time for all amputees was 242 ms during practice and 272 ms during testing. Motor recruitment synchronization varied across subjects, and amputees with the highest synchronization achieved the fastest movement times. End-point accuracy was independent of movement time. Results suggest that it is feasible for transtibial amputees to generate ballistic control signals using their residual muscles. Future work on volitional control of powered power ankle prostheses might consider anticipatory postural control based on ballistic-like residual muscle activation patterns and direct continuous proportional myoelectric control.

  1. SU-F-T-392: Superior Brainstem and Cochlea Sparing with VMAT for Glioblastoma Multiforme

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Briere, TM; McAleer, MF; Levy, LB

    Purpose: Volumetric arc therapy (VMAT) can provide similar target coverage and normal tissue sparing as IMRT but with shorter treatment times. At our institution VMAT was adopted for the treatment glioblastoma multiforme (GBM) after a small number of test plans demonstrated its non-inferiority. In this study, we compare actual clinical treatment plans for a larger cohort of patients treated with either VMAT or IMRT. Methods: 90 GBM patients were included in this study, 45 treated with IMRT and 45 with VMAT. All planning target volumes (PTVs) were prescribed a dose of 50 Gy, with a simultaneous integrated boost to 60more » Gy. Most IMRT plans used 5 non-coplanar beams, while most VMAT plans used 2 coplanar beams. Statistical analysis was performed using Fisher’s exact test or the Wilcoxon-Mann-Whitney rank sum test. Included in the analysis were patient and treatment characteristics as well as the doses to the target volumes and organs at risk. Results: Treatment times for the VMAT plans were reduced by 5 minutes compared with IMRT. The PTV coverage was similar, with at least 95% covered for all plans, while the median boost PTV dose differed by 0.1 Gy between the IMRT and VMAT cohorts. The doses to the brain, optic chiasm, optic nerves and eyes were not significantly different. The mean dose to the brainstem, however, was 9.4 Gy less with VMAT (p<0.001). The dose to the ipsilateral and contralateral cochleae were respectively 19.7 and 9.5 Gy less (p<0.001). Conclusion: Comparison of clinical treatment plans for separate IMRT and VMAT cohorts demonstrates that VMAT can save substantial treatment time while providing similar target coverage and superior sparing of the brainstem and cochleae. To our knowledge this is the first study to demonstrate this benefit of VMAT in the management of GBM.« less

  2. Collaborative Testing as a Model for Addressing Equity in Student Success in STEM Classes

    NASA Astrophysics Data System (ADS)

    Dileonardo, C.; James, B. R.

    2016-12-01

    Introductory Earth science classes at two-year colleges play a critical role as "gateway courses" for underrepresented student populations into undergraduate STEM programs. Students entering college underprepared in math and science typically receive their only exposure to science at the undergraduate level in introductory courses in the Earth and space sciences. In many colleges a huge disparity exists in these classes between success rates amongst students from groups traditionally represented in the STEM fields and those from underrepresented populations. Closing the equity gap in success in these courses is a major focus of many pilot projects nationally. This concern has also led to the adoption of new teaching and learning practices, based on research in learning, in introductory Earth science pedagogy. Models of teaching practices including greater engagement, active learning approaches, and collaborative learning structures seem to help with student achievement in introductory courses. But, whereas these practices might increase overall student success they have not proven to close the equity gap in achievement. De Anza a two-year college in the San Francisco bay area has a long history in the geology department of incorporating and testing teaching practices developed out of research in learning. Collaborative learning has infused every aspect of our learning approaches in the Earth sciences, including laboratory, fieldwork, and test preparation. Though these approaches seemed to have educational benefit the huge equity gap department-wide persisted between targeted and non-targeted populations. Three years ago collaborative testing models were introduced into our geology and meteorology classes. The mechanism included methods for directly comparing collaborative to individual testing. The net result was that targeted populations including African Americans, Latinos, and Filipinos increased steadily at around 3.5% per year from 66% to 73%. The overall success rates of the non-targeted groups remained between 84% and 86%. Preliminary analysis suggests that for disengaged students in the targeted populations the opportunity to collaborate on a portion of the actual test got them more involved in the collaborative process as it offers immediate tangible return on in-class success.

  3. Methodological comparisons for antimicrobial resistance surveillance in feedlot cattle

    PubMed Central

    2013-01-01

    Background The purpose of this study was to objectively compare methodological approaches that might be utilized in designing an antimicrobial resistance (AMR) surveillance program in beef feedlot cattle. Specifically, four separate comparisons were made to investigate their potential impact on estimates for prevalence of AMR. These included investigating potential differences between 2 different susceptibility testing methods (broth microdilution and disc diffusion), between 2 different target bacteria (non-type-specific E. coli [NTSEC] and Mannheimia haemolytica), between 2 strategies for sampling feces (individual samples collected per rectum and pooled samples collected from the pen floor), and between 2 strategies for determining which cattle to sample (cattle that were culture-positive for Mannheimia haemolytica and those that were culture-negative). Results Comparing two susceptibility testing methods demonstrated differences in the likelihood of detecting resistance between automated disk diffusion (BioMIC®) and broth microdilution (Sensititre®) for both E. coli and M. haemolytica. Differences were also detected when comparing resistance between two bacterial organisms within the same cattle; there was a higher likelihood of detecting resistance in E. coli than in M. haemolytica. Differences in resistance prevalence were not detected when using individual animal or composite pen sampling strategies. No differences in resistance prevalences were detected in E. coli recovered from cattle that were culture-positive for M. haemolytica compared to those that were culture-negative, suggesting that sampling strategies which targeted recovery of E. coli from M. haemolytica-positive cattle would not provide biased results. Conclusions We found that for general purposes, the susceptibility test selected for AMR surveillance must be carefully chosen considering the purpose of the surveillance since the ability to detect resistance appears to vary between these tests depending upon the population where they are applied. Continued surveillance of AMR in M. haemolytica recovered by nasopharyngeal swab is recommended if monitoring an animal health pathogen is an objective of the surveillance program as results of surveillance using fecal E. coli cannot be extrapolated to this important respiratory pathogen. If surveillance of E. coli was pursued in the same population, study populations could target animals that were culture-positive for M. haemolytica without biasing estimates for AMR in E. coli. Composite pen-floor sampling or sampling of individuals per-rectum could possibly be used interchangeably for monitoring resistance in E. coli. PMID:24144185

  4. Tumor Endothelial Marker Imaging in Melanomas Using Dual-Tracer Fluorescence Molecular Imaging

    PubMed Central

    Tichauer, Kenneth M.; Deharvengt, Sophie J.; Samkoe, Kimberley S.; Gunn, Jason R.; Bosenberg, Marcus W.; Turk, Mary-Jo; Hasan, Tayyaba; Stan, Radu V.; Pogue, Brian W.

    2014-01-01

    Purpose Cancer-specific endothelial markers available for intravascular binding are promising targets for new molecular therapies. In this study, a molecular imaging approach of quantifying endothelial marker concentrations (EMCI) is developed and tested in highly light-absorbing melanomas. The approach involves injection of targeted imaging tracer in conjunction with an untargeted tracer, which is used to account for nonspecific uptake and tissue optical property effects on measured targeted tracer concentrations. Procedures Theoretical simulations and a mouse melanoma model experiment were used to test out the EMCI approach. The tracers used in the melanoma experiments were fluorescently labeled anti-Plvap/PV1 antibody (plasmalemma vesicle associated protein Plvap/PV1 is a transmembrane protein marker exposed on the luminal surface of endothelial cells in tumor vasculature) and a fluorescent isotype control antibody, the uptakes of which were measured on a planar fluorescence imaging system. Results The EMCI model was found to be robust to experimental noise under reversible and irreversible binding conditions and was capable of predicting expected overexpression of PV1 in melanomas compared to healthy skin despite a 5-time higher measured fluorescence in healthy skin compared to melanoma: attributable to substantial light attenuation from melanin in the tumors. Conclusions This study demonstrates the potential of EMCI to quantify endothelial marker concentrations in vivo, an accomplishment that is currently unavailable through any other methods, either in vivo or ex vivo. PMID:24217944

  5. Knowledge-transfer learning for prediction of matrix metalloprotease substrate-cleavage sites.

    PubMed

    Wang, Yanan; Song, Jiangning; Marquez-Lago, Tatiana T; Leier, André; Li, Chen; Lithgow, Trevor; Webb, Geoffrey I; Shen, Hong-Bin

    2017-07-18

    Matrix Metalloproteases (MMPs) are an important family of proteases that play crucial roles in key cellular and disease processes. Therefore, MMPs constitute important targets for drug design, development and delivery. Advanced proteomic technologies have identified type-specific target substrates; however, the complete repertoire of MMP substrates remains uncharacterized. Indeed, computational prediction of substrate-cleavage sites associated with MMPs is a challenging problem. This holds especially true when considering MMPs with few experimentally verified cleavage sites, such as for MMP-2, -3, -7, and -8. To fill this gap, we propose a new knowledge-transfer computational framework which effectively utilizes the hidden shared knowledge from some MMP types to enhance predictions of other, distinct target substrate-cleavage sites. Our computational framework uses support vector machines combined with transfer machine learning and feature selection. To demonstrate the value of the model, we extracted a variety of substrate sequence-derived features and compared the performance of our method using both 5-fold cross-validation and independent tests. The results show that our transfer-learning-based method provides a robust performance, which is at least comparable to traditional feature-selection methods for prediction of MMP-2, -3, -7, -8, -9 and -12 substrate-cleavage sites on independent tests. The results also demonstrate that our proposed computational framework provides a useful alternative for the characterization of sequence-level determinants of MMP-substrate specificity.

  6. Cytoarchitecture of steroid dependent target tissues after testosterone administration compared to nandrolone decanoate in castrated rats in the aim of Hershberger bio test.

    PubMed

    Cristina, Romeo Teodor; Hanganu, Flavia; Brezovan, Diana; Dumitrescu, Eugenia; Muselin, Florin; Chiurciu, Viorica; Stancu, Adrian Constantin; Pentea, Marius Cristian; Motoc, Andrei Gheorghe Marius

    2014-01-01

    The objective was the cytoarchitecture evaluation of known steroid dependent target tissues after administering of testosterone, compared to action of its more active ester, nortestosterone (nandrolone decanoate) in castrated rat males in the aim of Hershberger bio test. Study was performed on 30 castrated male Wistar rats, aged between 35 and 39 days, in peripubertal period, divided into five groups. Androgen doses administration begun at the rats' age of 49 days. Animals were injected i.m., daily, for 10 consecutive days as follows: Aquatest (Balkan Pharmaceuticals Ltd., Moldova) testosterone aqueous solution: Testosterone I group (0.4 mg/animal); Testosterone II (0.8 mg/animal); (Deca-Durabolin, Balkan Pharmaceuticals); nandrolone decanoate oily solution: Nortestosterone I (1.5 mg/kg body weight); Nortestosterone II (7.5 mg/kg body weight) and Control (White sesame oil, Manicos, Romania, 0.1 mL/animal). Gonadectomy (GDX) induced modifications of target tissues wet weight accompanied by important modifications in cytoarchitecture. Changes following exogenous administration of testosterone and nortestosterone decanoate were found in: liver (granular dystrophy, mega-mitochondria, tubular intumescences), prostate (increasing of the structural elements), seminal vesicles (hyalinosis, thickening of cell walls and the hyaline presence), levator ani-bulbo-cavernosus muscle (muscle fibbers dilacerations), bulbourethral glands (muscular fibbers rarefaction by fluid accumulation) demonstrating the disruptor activity especially for overdosed nandrolone decanoate.

  7. Why do water quality monitoring programs succeed or fail? A qualitative comparative analysis of regulated testing systems in sub-Saharan Africa.

    PubMed

    Peletz, Rachel; Kisiangani, Joyce; Bonham, Mateyo; Ronoh, Patrick; Delaire, Caroline; Kumpel, Emily; Marks, Sara; Khush, Ranjiv

    2018-05-31

    Water quality testing is critical for guiding water safety management and ensuring public health. In many settings, however, water suppliers and surveillance agencies do not meet regulatory requirements for testing frequencies. This study examines the conditions that promote successful water quality monitoring in Africa, with the goal of providing evidence for strengthening regulated water quality testing programs. We compared monitoring programs among 26 regulated water suppliers and surveillance agencies across six African countries. These institutions submitted monthly water quality testing results over 18 months. We also collected qualitative data on the conditions that influenced testing performance via approximately 821 h of semi-structured interviews and observations. Based on our qualitative data, we developed the Water Capacity Rating Diagnostic (WaterCaRD) to establish a scoring framework for evaluating the effects of the following conditions on testing performance: accountability, staffing, program structure, finances, and equipment & services. We summarized the qualitative data into case studies for each of the 26 institutions and then used the case studies to score the institutions against the conditions captured in WaterCaRD. Subsequently, we applied fuzzy-set Qualitative Comparative Analysis (fsQCA) to compare these scores against performance outcomes for water quality testing. We defined the performance outcomes as the proportion of testing Targets Achieved (outcome 1) and Testing Consistency (outcome 2) based on the monthly number of microbial water quality tests conducted by each institution. Our analysis identified motivation & leadership, knowledge, staff retention, and transport as institutional conditions that were necessary for achieving monitoring targets. In addition, equipment, procurement, infrastructure, and enforcement contributed to the pathways that resulted in strong monitoring performance. Our identification of institutional commitment, comprising motivation & leadership, knowledge, and staff retention, as a key driver of monitoring performance was not surprising: in weak regulatory environments, individuals and their motivations take-on greater importance in determining institutional and programmatic outcomes. Nevertheless, efforts to build data collection capacity in low-resource settings largely focus on supply-side interventions: the provision of infrastructure, equipment, and training sessions. Our results indicate that these interventions will continue to have limited long-term impacts and sustainability without complementary strategies for motivating or incentivizing water supply and surveillance agency managers to achieve testing goals. More broadly, our research demonstrates both an experimental approach for diagnosing the systems that underlie service provision and an analytical strategy for identifying appropriate interventions. Copyright © 2018 The Authors. Published by Elsevier GmbH.. All rights reserved.

  8. Lessons learned from use of social network strategy in HIV testing programs targeting African American men who have sex with men.

    PubMed

    McCree, Donna H; Millett, Gregorio; Baytop, Chanza; Royal, Scott; Ellen, Jonathan; Halkitis, Perry N; Kupprat, Sandra A; Gillen, Sara

    2013-10-01

    We report lessons derived from implementation of the Social Network Strategy (SNS) into existing HIV counseling, testing, and referral services targeting 18- to 64-year-old Black gay, bisexual, and other men who have sex with men (MSM). The SNS procedures used in this study were adapted from a Centers for Disease Control and Prevention-funded, 2-year demonstration project involving 9 community-based organizations (CBOs) in 7 cities. Under the SNS, HIV-positive and HIV-negative men at high risk for HIV (recruiters) were enlisted to identify and recruit persons from their social, sexual, or drug-using networks (network associates) for HIV testing. Sites maintained records of modified study protocols for ascertaining lessons learned. The study was conducted between April 2008 and May 2010 at CBOs in Washington, DC, and New York, New York, and at a health department in Baltimore, Maryland. Several common lessons regarding development of the plan, staffing, training, and use of incentives were identified across the sites. Collectively, these lessons indicate use of SNS is resource-intensive, requiring a detailed plan, dedicated staff, and continual input from clients and staff for successful implementation. SNS may provide a strategy for identifying and targeting clusters of high-risk Black MSM for HIV testing. Given the resources needed to implement the strategy, additional studies using an experimental design are needed to determine the cost-effectiveness of SNS compared with other testing strategies.

  9. Testing a novel method for improving wayfinding by means of a P3b Virtual Reality Visual Paradigm in normal aging.

    PubMed

    de Tommaso, Marina; Ricci, Katia; Delussi, Marianna; Montemurno, Anna; Vecchio, Eleonora; Brunetti, Antonio; Bevilacqua, Vitoantonio

    2016-01-01

    We propose a virtual reality (VR) model, reproducing a house environment, where color modification of target places, obtainable by home automation in a real ambient, was tested by means of a P3b paradigm. The target place (bathroom door) was designed to be recognized during a virtual wayfinding in a realistic reproduction of a house environment. Different color and luminous conditions, easily obtained in the real ambient from a remote home automation control, were applied to the target and standard places, all the doors being illuminated in white (W), and only target doors colored with a green (G) or red (R) spotlight. Three different Virtual Environments (VE) were depicted, as the bathroom was designed in the aisle (A), living room (L) and bedroom (B). EEG was recorded from 57 scalp electrodes in 10 healthy subjects in the 60-80 year age range (O-old group) and 12 normal cases in the 20-30 year age range (Y-young group). In Young group, all the target stimuli determined a significant increase in P3b amplitude on the parietal, occipital and central electrodes compared to frequent stimuli condition, whatever was the color of the target door, while in elderly group the P3b obtained by the green and red colors was significantly different from the frequent stimulus, on the parietal, occipital, and central derivations, while the White stimulus did not evoke a significantly larger P3b with respect to frequent stimulus. The modulation of P3b amplitude, obtained by color and luminance change of target place, suggests that cortical resources, able to compensate the age-related progressive loss of cognitive performance, need to be facilitated even in normal elderly. The event-related responses obtained by virtual reality may be a reliable method to test the environmental feasibility to age-related cognitive changes.

  10. Emotion Words: Adding Face Value.

    PubMed

    Fugate, Jennifer M B; Gendron, Maria; Nakashima, Satoshi F; Barrett, Lisa Feldman

    2017-06-12

    Despite a growing number of studies suggesting that emotion words affect perceptual judgments of emotional stimuli, little is known about how emotion words affect perceptual memory for emotional faces. In Experiments 1 and 2 we tested how emotion words (compared with control words) affected participants' abilities to select a target emotional face from among distractor faces. Participants were generally more likely to false alarm to distractor emotional faces when primed with an emotion word congruent with the face (compared with a control word). Moreover, participants showed both decreased sensitivity (d') to discriminate between target and distractor faces, as well as altered response biases (c; more likely to answer "yes") when primed with an emotion word (compared with a control word). In Experiment 3 we showed that emotion words had more of an effect on perceptual memory judgments when the structural information in the target face was limited, as well as when participants were only able to categorize the face with a partially congruent emotion word. The overall results are consistent with the idea that emotion words affect the encoding of emotional faces in perceptual memory. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  11. Change Analysis in Structural Laser Scanning Point Clouds: The Baseline Method

    PubMed Central

    Shen, Yueqian; Lindenbergh, Roderik; Wang, Jinhu

    2016-01-01

    A method is introduced for detecting changes from point clouds that avoids registration. For many applications, changes are detected between two scans of the same scene obtained at different times. Traditionally, these scans are aligned to a common coordinate system having the disadvantage that this registration step introduces additional errors. In addition, registration requires stable targets or features. To avoid these issues, we propose a change detection method based on so-called baselines. Baselines connect feature points within one scan. To analyze changes, baselines connecting corresponding points in two scans are compared. As feature points either targets or virtual points corresponding to some reconstructable feature in the scene are used. The new method is implemented on two scans sampling a masonry laboratory building before and after seismic testing, that resulted in damages in the order of several centimeters. The centres of the bricks of the laboratory building are automatically extracted to serve as virtual points. Baselines connecting virtual points and/or target points are extracted and compared with respect to a suitable structural coordinate system. Changes detected from the baseline analysis are compared to a traditional cloud to cloud change analysis demonstrating the potential of the new method for structural analysis. PMID:28029121

  12. Change Analysis in Structural Laser Scanning Point Clouds: The Baseline Method.

    PubMed

    Shen, Yueqian; Lindenbergh, Roderik; Wang, Jinhu

    2016-12-24

    A method is introduced for detecting changes from point clouds that avoids registration. For many applications, changes are detected between two scans of the same scene obtained at different times. Traditionally, these scans are aligned to a common coordinate system having the disadvantage that this registration step introduces additional errors. In addition, registration requires stable targets or features. To avoid these issues, we propose a change detection method based on so-called baselines. Baselines connect feature points within one scan. To analyze changes, baselines connecting corresponding points in two scans are compared. As feature points either targets or virtual points corresponding to some reconstructable feature in the scene are used. The new method is implemented on two scans sampling a masonry laboratory building before and after seismic testing, that resulted in damages in the order of several centimeters. The centres of the bricks of the laboratory building are automatically extracted to serve as virtual points. Baselines connecting virtual points and/or target points are extracted and compared with respect to a suitable structural coordinate system. Changes detected from the baseline analysis are compared to a traditional cloud to cloud change analysis demonstrating the potential of the new method for structural analysis.

  13. A robust algorithm for automated target recognition using precomputed radar cross sections

    NASA Astrophysics Data System (ADS)

    Ehrman, Lisa M.; Lanterman, Aaron D.

    2004-09-01

    Passive radar is an emerging technology that offers a number of unique benefits, including covert operation. Many such systems are already capable of detecting and tracking aircraft. The goal of this work is to develop a robust algorithm for adding automated target recognition (ATR) capabilities to existing passive radar systems. In previous papers, we proposed conducting ATR by comparing the precomputed RCS of known targets to that of detected targets. To make the precomputed RCS as accurate as possible, a coordinated flight model is used to estimate aircraft orientation. Once the aircraft's position and orientation are known, it is possible to determine the incident and observed angles on the aircraft, relative to the transmitter and receiver. This makes it possible to extract the appropriate radar cross section (RCS) from our simulated database. This RCS is then scaled to account for propagation losses and the receiver's antenna gain. A Rician likelihood model compares these expected signals from different targets to the received target profile. We have previously employed Monte Carlo runs to gauge the probability of error in the ATR algorithm; however, generation of a statistically significant set of Monte Carlo runs is computationally intensive. As an alternative to Monte Carlo runs, we derive the relative entropy (also known as Kullback-Liebler distance) between two Rician distributions. Since the probability of Type II error in our hypothesis testing problem can be expressed as a function of the relative entropy via Stein's Lemma, this provides us with a computationally efficient method for determining an upper bound on our algorithm's performance. It also provides great insight into the types of classification errors we can expect from our algorithm. This paper compares the numerically approximated probability of Type II error with the results obtained from a set of Monte Carlo runs.

  14. A signature correlation study of ground target VHF/UHF ISAR imagery

    NASA Astrophysics Data System (ADS)

    Gatesman, Andrew J.; Beaudoin, Christopher J.; Giles, Robert H.; Kersey, William T.; Waldman, Jerry; Carter, Steve; Nixon, William E.

    2003-09-01

    VV and HH-polarized radar signatures of several ground targets were acquired in the VHF/UHF band (171-342 MHz) by using 1/35th scale models and an indoor radar range operating from 6 to 12 GHz. Data were processed into medianized radar cross sections as well as focused, ISAR imagery. Measurement validation was confirmed by comparing the radar cross section of a test object with a method of moments radar cross section prediction code. The signatures of several vehicles from three vehicle classes (tanks, trunks, and TELs) were measured and a signature cross-correlation study was performed. The VHF/UHF band is currently being exploited for its foliage penetration ability, however, the coarse image resolution which results from the relatively long radar wavelengths suggests a more challenging target recognition problem. One of the study's goals was to determine the amount of unique signature content in VHF/UHF ISAR imagery of military ground vehicles. Open-field signatures are compared with each other as well as with simplified shapes of similar size. Signatures were also acquired on one vehicle in a variety of configurations to determine the impact of monitor target variations on the signature content at these frequencies.

  15. Place and response learning in human virtual navigation: behavioral measures and gender differences.

    PubMed

    Schmitzer-Torbert, Neil

    2007-04-01

    Two experiments examined the use of place and response strategies by humans navigating virtual multiple T mazes. In Experiment 1, probe trials revealed that participants commonly used place and response strategies, and place strategies were more frequent early in training, whereas response strategies were more frequent late in training. Compared with women, men learned the correct path through the maze more quickly and developed a more stable route through the maze. In Experiment 2, participants were trained to locate 2 targets. One target required participants to use either a place or response strategy, whereas the other target could be found using either strategy. Accuracy improved faster for place training compared with response training, and women outperformed men in both groups. Probe trials testing transfer of the imposed strategy to the other target found faster transfer for place training than for response training and that women demonstrated faster transfer than men. Accuracy on probe trials was correlated with poor route stability in the place-trained group and with good route stability in the response-trained group, indicating that navigation strategy use may be related to measures of improvement in performance on normal trials. (c) 2007 APA, all rights reserved

  16. Test target for characterizing 3D resolution of optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Hu, Zhixiong; Hao, Bingtao; Liu, Wenli; Hong, Baoyu; Li, Jiao

    2014-12-01

    Optical coherence tomography (OCT) is a non-invasive 3D imaging technology which has been applied or investigated in many diagnostic fields including ophthalmology, dermatology, dentistry, cardiovasology, endoscopy, brain imaging and so on. Optical resolution is an important characteristic that can describe the quality and utility of an image acquiring system. We employ 3D printing technology to design and fabricate a test target for characterizing 3D resolution of optical coherence tomography. The test target which mimics USAF 1951 test chart was produced with photopolymer. By measuring the 3D test target, axial resolution as well as lateral resolution of a spectral domain OCT system was evaluated. For comparison, conventional microscope and surface profiler were employed to characterize the 3D test targets. The results demonstrate that the 3D resolution test targets have the potential of qualitatively and quantitatively validating the performance of OCT systems.

  17. Wide-Scope Screening Method for Multiclass Veterinary Drug Residues in Fish, Shrimp, and Eel Using Liquid Chromatography-Quadrupole High-Resolution Mass Spectrometry.

    PubMed

    Turnipseed, Sherri B; Storey, Joseph M; Lohne, Jack J; Andersen, Wendy C; Burger, Robert; Johnson, Aaron S; Madson, Mark R

    2017-08-30

    A screening method for veterinary drug residues in fish, shrimp, and eel using LC with a high-resolution MS instrument has been developed and validated. The method was optimized for over 70 test compounds representing a variety of veterinary drug classes. Tissues were extracted by vortex mixing with acetonitrile acidified with 2% acetic acid and 0.2% p-toluenesulfonic acid. A centrifuged portion of the extract was passed through a novel solid phase extraction cartridge designed to remove interfering matrix components from tissue extracts. The eluent was then evaporated and reconstituted for analysis. Data were collected with a quadrupole-Orbitrap high-resolution mass spectrometer using both nontargeted and targeted acquisition methods. Residues were detected on the basis of the exact mass of the precursor and a product ion along with isotope pattern and retention time matching. Semiquantitative data analysis compared MS 1 signal to a one-point extracted matrix standard at a target testing level. The test compounds were detected and identified in salmon, tilapia, catfish, shrimp, and eel extracts fortified at the target testing levels. Fish dosed with selected analytes and aquaculture samples previously found to contain residues were also analyzed. The screening method can be expanded to monitor for an additional >260 veterinary drugs on the basis of exact mass measurements and retention times.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maurer, J; Sintay, B; Manning, M

    Purpose: This study evaluates a novel algorithm that can be used with any treatment planning system for simple and rapid generation of stereotactic radiosurgery (SRS) plans for treating multiple brain metastases using a single isocenter dynamic conformal arc (DCA) approach. This technique is compared with a single isocenter volumetric modulated arc therapy (VMAT) technique in terms of delivery time, conformity, low dose spread and delivery accuracy. Methods: Five patients, with a total of 37 (5 – 11) targets were planned using a previously published method for generating optimal VMAT plans and using the proposed DCA algorithm. All planning target volumesmore » (PTVs) were planned to 20 Gy, meeting a minimum 99% coverage and maximum 135 % hot spot for both techniques. Quality assurance was performed using radiochromic film, with films placed in the high dose regions of each PTV. Normal tissue volumes receiving 12 Gy and 6 Gy (V12 and V6) were computed for each plan. Conformity index (CI) and gamma evaluations (95% of points passing 4%/0.5mm) were computed for each PTV. Results: Delivery times, including beam on and table rotation times, were comparable: 17 – 22 minutes for all deliveries. V12s for DCA plans were (18.5±15.2 cc) vs. VMAT (19.7±14.4 cc). V6s were significantly lower for DCA (69.0±52.0 cc) compared with VMAT (154.0±91.0 cc) (p <<0.05). CIs for VMAT targets were (1.38±0.50) vs. DCA (1.61±0.41). 36 of 37 DCA planned targets passed gamma tests, while 29 of 37 VMAT planned targets passed. Conclusion: Single isocenter DCA plans were easily achieved. The evaluation suggests that DCA may represent a favorable technique compared with VMAT for multiple target SRS by reducing dose to normal tissue and more accurately depicting deliverable dose.« less

  19. Application of thin-plate spline transformations to finite element models, or, how to turn a bog turtle into a spotted turtle to analyze both.

    PubMed

    Stayton, C Tristan

    2009-05-01

    Finite element (FE) models are popular tools that allow biologists to analyze the biomechanical behavior of complex anatomical structures. However, the expense and time required to create models from specimens has prevented comparative studies from involving large numbers of species. A new method is presented for transforming existing FE models using geometric morphometric methods. Homologous landmark coordinates are digitized on the FE model and on a target specimen into which the FE model is being transformed. These coordinates are used to create a thin-plate spline function and coefficients, which are then applied to every node in the FE model. This function smoothly interpolates the location of points between landmarks, transforming the geometry of the original model to match the target. This new FE model is then used as input in FE analyses. This procedure is demonstrated with turtle shells: a Glyptemys muhlenbergii model is transformed into Clemmys guttata and Actinemys marmorata models. Models are loaded and the resulting stresses are compared. The validity of the models is tested by crushing actual turtle shells in a materials testing machine and comparing those results to predictions from FE models. General guidelines, cautions, and possibilities for this procedure are also presented.

  20. Brief Report: Gonorrhea and Chlamydia Testing Increasing but Still Lagging in HIV Clinics in the United States.

    PubMed

    Berry, Stephen A; Ghanem, Khalil G; Mathews, William Christopher; Korthuis, Philip Todd; Yehia, Baligh R; Agwu, Allison L; Lehmann, Christoph U; Moore, Richard D; Allen, Sara L; Gebo, Kelly A

    2015-11-01

    Screening persons living with HIV for gonorrhea and chlamydia has been recommended since 2003. We compared annual gonorrhea/chlamydia testing to syphilis and lipid testing among 19,368 adults (41% men who have sex with men, 30% heterosexual men, and 29% women) engaged in HIV care. In 2004, 22%, 62%, and 70% of all patients were tested for gonorrhea/chlamydia, syphilis, and lipid levels, respectively. Despite increasing steadily [odds ratio per year (95% confidence interval): 1.14 (1.13 to 1.15)], gonorrhea/chlamydia testing in 2010 remained lower than syphilis and lipid testing (39%, 77%, 76%, respectively). Interventions to improve gonorrhea/chlamydia screening are needed. A more targeted screening approach may be warranted.

  1. A Biomechanical Comparison of Proportional Electromyography Control to Biological Torque Control Using a Powered Hip Exoskeleton.

    PubMed

    Young, Aaron J; Gannon, Hannah; Ferris, Daniel P

    2017-01-01

    Despite a large increase in robotic exoskeleton research, there are few studies that have examined human performance with different control strategies on the same exoskeleton device. Direct comparison studies are needed to determine how users respond to different types of control. The purpose of this study was to compare user performance using a robotic hip exoskeleton with two different controllers: a controller that targeted a biological hip torque profile and a proportional myoelectric controller. We tested both control approaches on 10 able-bodied subjects using a pneumatically powered hip exoskeleton. The state machine controller targeted a biological hip torque profile. The myoelectric controller used electromyography (EMG) of lower limb muscles to produce a proportional control signal for the hip exoskeleton. Each subject performed two 30-min exoskeleton walking trials (1.0 m/s) using each controller and a 10-min trial with the exoskeleton unpowered. During each trial, we measured subjects' metabolic cost of walking, lower limb EMG profiles, and joint kinematics and kinetics (torques and powers) using a force treadmill and motion capture. Compared to unassisted walking in the exoskeleton, myoelectric control significantly reduced metabolic cost by 13% ( p  = 0.005) and biological hip torque control reduced metabolic cost by 7% ( p  = 0.261). Subjects reduced muscle activity relative to the unpowered condition for a greater number of lower limb muscles using myoelectric control compared to the biological hip torque control. More subjects subjectively preferred the myoelectric controller to the biological hip torque control. Myoelectric control had more advantages (metabolic cost and muscle activity reduction) compared to a controller that targeted a biological torque profile for walking with a robotic hip exoskeleton. However, these results were obtained with a single exoskeleton device with specific control configurations while level walking at a single speed. Further testing on different exoskeleton hardware and with more varied experimental protocols, such as testing over multiple types of terrain, is needed to fully elucidate the potential benefits of myoelectric control for exoskeleton technology.

  2. Metrology test object for dimensional verification in additive manufacturing of metals for biomedical applications.

    PubMed

    Teeter, Matthew G; Kopacz, Alexander J; Nikolov, Hristo N; Holdsworth, David W

    2015-01-01

    Additive manufacturing continues to increase in popularity and is being used in applications such as biomaterial ingrowth that requires sub-millimeter dimensional accuracy. The purpose of this study was to design a metrology test object for determining the capabilities of additive manufacturing systems to produce common objects, with a focus on those relevant to medical applications. The test object was designed with a variety of features of varying dimensions, including holes, cylinders, rectangles, gaps, and lattices. The object was built using selective laser melting, and the produced dimensions were compared to the target dimensions. Location of the test objects on the build plate did not affect dimensions. Features with dimensions less than 0.300 mm did not build or were overbuilt to a minimum of 0.300 mm. The mean difference between target and measured dimensions was less than 0.100 mm in all cases. The test object is applicable to multiple systems and materials, tests the effect of location on the build, uses a minimum of material, and can be measured with a variety of efficient metrology tools (including measuring microscopes and micro-CT). Investigators can use this test object to determine the limits of systems and adjust build parameters to achieve maximum accuracy. © IMechE 2014.

  3. Stroke preparedness in children: translating knowledge into behavioral intent: a systematic review and meta-analysis.

    PubMed

    Ottawa, Cassandra; Sposato, Luciano A; Nabbouh, Fadl; Saposnik, Gustavo

    2015-10-01

    If translated into behavioral intent, improving stroke knowledge may potentially impact on better outcomes. Children are an attractive target population since they can drive familial behavioral changes. However, the impact of interventions on stroke knowledge among children is unclear. We performed a systematic review and meta-analysis to investigate whether educational interventions targeting children improve stroke knowledge and lead to behavioral changes. We searched Ovid, PubMed, and Embase between January 2000 and December 2014. We included studies written in English reporting the number of children aged 6-15 years undergoing educational interventions on stroke and providing the results for baseline and early and late postintervention tests. We compared the proportion of correct answers between baseline, early, and late responses for two endpoints: knowledge and behavioral intent. Of the initial 58 articles found, we included nine that met the inclusion criteria. Compared with baseline tests (51·7%, 95% confidence interval 40·9-62·4), there was improvement in stroke knowledge in early (74·0%, 95% confidence interval 64·4-82·5, P = 0·002) and late (67·3%, 95% confidence interval 55·4-78·2, P = 0·027) responses. There was improvement in the early (92·1%, 95% confidence interval 86·0-96·6, P < 0·001) and late (83·9%, 95% confidence interval 73·5-92·1, P = 0·001) responses for behavioral intent compared with the baseline assessment (63·8%, 95% confidence interval 53·5-73·4). Children are a potentially attractive target population for improvement in stroke knowledge and behavioral intent, both in the short and long term. Our findings may support the implementation of large-scale stroke educational initiatives targeting children. © 2015 World Stroke Organization.

  4. Transiting Exoplanet Studies and Community Targets for JWST's Early Release Science Program

    NASA Astrophysics Data System (ADS)

    Stevenson, Kevin B.; Lewis, Nikole K.; Bean, Jacob L.; Beichman, Charles; Fraine, Jonathan; Kilpatrick, Brian M.; Krick, J. E.; Lothringer, Joshua D.; Mandell, Avi M.; Valenti, Jeff A.; Agol, Eric; Angerhausen, Daniel; Barstow, Joanna K.; Birkmann, Stephan M.; Burrows, Adam; Charbonneau, David; Cowan, Nicolas B.; Crouzet, Nicolas; Cubillos, Patricio E.; Curry, S. M.; Dalba, Paul A.; de Wit, Julien; Deming, Drake; Désert, Jean-Michel; Doyon, René; Dragomir, Diana; Ehrenreich, David; Fortney, Jonathan J.; García Muñoz, Antonio; Gibson, Neale P.; Gizis, John E.; Greene, Thomas P.; Harrington, Joseph; Heng, Kevin; Kataria, Tiffany; Kempton, Eliza M.-R.; Knutson, Heather; Kreidberg, Laura; Lafrenière, David; Lagage, Pierre-Olivier; Line, Michael R.; Lopez-Morales, Mercedes; Madhusudhan, Nikku; Morley, Caroline V.; Rocchetto, Marco; Schlawin, Everett; Shkolnik, Evgenya L.; Shporer, Avi; Sing, David K.; Todorov, Kamen O.; Tucker, Gregory S.; Wakeford, Hannah R.

    2016-09-01

    The James Webb Space Telescope (JWST) will likely revolutionize transiting exoplanet atmospheric science, due to a combination of its capability for continuous, long duration observations and its larger collecting area, spectral coverage, and spectral resolution compared to existing space-based facilities. However, it is unclear precisely how well JWST will perform and which of its myriad instruments and observing modes will be best suited for transiting exoplanet studies. In this article, we describe a prefatory JWST Early Release Science (ERS) Cycle 1 program that focuses on testing specific observing modes to quickly give the community the data and experience it needs to plan more efficient and successful transiting exoplanet characterization programs in later cycles. We propose a multi-pronged approach wherein one aspect of the program focuses on observing transits of a single target with all of the recommended observing modes to identify and understand potential systematics, compare transmission spectra at overlapping and neighboring wavelength regions, confirm throughputs, and determine overall performances. In our search for transiting exoplanets that are well suited to achieving these goals, we identify 12 objects (dubbed “community targets”) that meet our defined criteria. Currently, the most favorable target is WASP-62b because of its large predicted signal size, relatively bright host star, and location in JWST's continuous viewing zone. Since most of the community targets do not have well-characterized atmospheres, we recommend initiating preparatory observing programs to determine the presence of obscuring clouds/hazes within their atmospheres. Measurable spectroscopic features are needed to establish the optimal resolution and wavelength regions for exoplanet characterization. Other initiatives from our proposed ERS program include testing the instrument brightness limits and performing phase-curve observations. The latter are a unique challenge compared to transit observations because of their significantly longer durations. Using only a single mode, we propose to observe a full-orbit phase curve of one of the previously characterized, short-orbital-period planets to evaluate the facility-level aspects of long, uninterrupted time-series observations.

  5. TargetLink, a new method for identifying the endogenous target set of a specific microRNA in intact living cells.

    PubMed

    Xu, Yan; Chen, Yan; Li, Daliang; Liu, Qing; Xuan, Zhenyu; Li, Wen-Hong

    2017-02-01

    MicroRNAs are small non-coding RNAs acting as posttranscriptional repressors of gene expression. Identifying mRNA targets of a given miRNA remains an outstanding challenge in the field. We have developed a new experimental approach, TargetLink, that applied locked nucleic acid (LNA) as the affinity probe to enrich target genes of a specific microRNA in intact cells. TargetLink also consists a rigorous and systematic data analysis pipeline to identify target genes by comparing LNA-enriched sequences between experimental and control samples. Using miR-21 as a test microRNA, we identified 12 target genes of miR-21 in a human colorectal cancer cell by this approach. The majority of the identified targets interacted with miR-21 via imperfect seed pairing. Target validation confirmed that miR-21 repressed the expression of the identified targets. The cellular abundance of the identified miR-21 target transcripts varied over a wide range, with some targets expressed at a rather low level, confirming that both abundant and rare transcripts are susceptible to regulation by microRNAs, and that TargetLink is an efficient approach for identifying the target set of a specific microRNA in intact cells. C20orf111, one of the novel targets identified by TargetLink, was found to reside in the nuclear speckle and to be reliably repressed by miR-21 through the interaction at its coding sequence.

  6. Long-term adaptation to change in implicit contextual learning.

    PubMed

    Zellin, Martina; von Mühlenen, Adrian; Müller, Hermann J; Conci, Markus

    2014-08-01

    The visual world consists of spatial regularities that are acquired through experience in order to guide attentional orienting. For instance, in visual search, detection of a target is faster when a layout of nontarget items is encountered repeatedly, suggesting that learned contextual associations can guide attention (contextual cuing). However, scene layouts sometimes change, requiring observers to adapt previous memory representations. Here, we investigated the long-term dynamics of contextual adaptation after a permanent change of the target location. We observed fast and reliable learning of initial context-target associations after just three repetitions. However, adaptation of acquired contextual representations to relocated targets was slow and effortful, requiring 3 days of training with overall 80 repetitions. A final test 1 week later revealed equivalent effects of contextual cuing for both target locations, and these were comparable to the effects observed on day 1. That is, observers learned both initial target locations and relocated targets, given extensive training combined with extended periods of consolidation. Thus, while implicit contextual learning efficiently extracts statistical regularities of our environment at first, it is rather insensitive to change in the longer term, especially when subtle changes in context-target associations need to be acquired.

  7. An Experiment Quantifying The Effect Of Clutter On Target Detection

    NASA Astrophysics Data System (ADS)

    Weathersby, Marshall R.; Schmieder, David E.

    1985-01-01

    Experiments were conducted to determine the influence of background clutter on target detection criteria. The experiment consisted of placing observers in front of displayed images on a TV monitor. Observer ability to detect military targets embedded in simulated natural and manmade background clutter was measured when there was unlimited viewing time. Results were described in terms of detection probability versus target resolution for various signal to clutter ratios (SCR). The experiments were preceded by a search for a meaningful clutter definition. The selected definition was a statistical measure computed by averaging the standard deviation of contiguous scene cells over the whole scene. The cell size was comparable to the target size. Observer test results confirmed the expectation that the resolution required for a given detection probability was a continuum function of the clutter level. At the lower SCRs the resolution required for a high probability of detection was near 6 lines pairs per target (LP/TGT), while at the higher SCRs it was found that a resolution of less than 0.25 LP/TGT would yield a high probability of detection. These results are expected to aid in target acquisition performance modeling and to lead to improved specifications for imaging automatic target screeners.

  8. Generation and assessment of turntable SAR data for the support of ATR development

    NASA Astrophysics Data System (ADS)

    Cohen, Marvin N.; Showman, Gregory A.; Sangston, K. James; Sylvester, Vincent B.; Gostin, Lamar; Scheer, C. Ruby

    1998-10-01

    Inverse synthetic aperture radar (ISAR) imaging on a turntable-tower test range permits convenient generation of high resolution two-dimensional images of radar targets under controlled conditions for testing SAR image processing and for supporting automatic target recognition (ATR) algorithm development. However, turntable ISAR images are often obtained under near-field geometries and hence may suffer geometric distortions not present in airborne SAR images. In this paper, turntable data collected at Georgia Tech's Electromagnetic Test Facility are used to begin to assess the utility of two- dimensional ISAR imaging algorithms in forming images to support ATR development. The imaging algorithms considered include a simple 2D discrete Fourier transform (DFT), a 2-D DFT with geometric correction based on image domain resampling, and a computationally-intensive geometric matched filter solution. Images formed with the various algorithms are used to develop ATR templates, which are then compared with an eye toward utilization in an ATR algorithm.

  9. Implicit and explicit forgetting: when is gist remembered?

    PubMed

    Dorfman, J; Mandler, G

    1994-08-01

    Recognition (YES/NO) and stem completion (cued: complete with a word from the list; and uncued: complete with the first word that comes to mind) were tested following either semantic or non-semantic processing of a categorized input list. Item/instance information was tested by contrasting target items from the input list with new items that were categorically related to them; gist/categorical information was tested by comparing target items semantically related to the input items with unrelated new items. For both recognition and stem completion, regardless of initial processing condition, item information decayed rapidly over a period of one week. Gist information was maintained over the same period when initial processing was semantic but only in the cued condition for completion. These results are discussed in terms of dual process theory, which postulates activation/integration of a representation as primarily relevant to implicit item information and elaboration of a representation as mainly relevant to semantic (i.e. categorical) information.

  10. MutScan: fast detection and visualization of target mutations by scanning FASTQ data.

    PubMed

    Chen, Shifu; Huang, Tanxiao; Wen, Tiexiang; Li, Hong; Xu, Mingyan; Gu, Jia

    2018-01-22

    Some types of clinical genetic tests, such as cancer testing using circulating tumor DNA (ctDNA), require sensitive detection of known target mutations. However, conventional next-generation sequencing (NGS) data analysis pipelines typically involve different steps of filtering, which may cause miss-detection of key mutations with low frequencies. Variant validation is also indicated for key mutations detected by bioinformatics pipelines. Typically, this process can be executed using alignment visualization tools such as IGV or GenomeBrowse. However, these tools are too heavy and therefore unsuitable for validating mutations in ultra-deep sequencing data. We developed MutScan to address problems of sensitive detection and efficient validation for target mutations. MutScan involves highly optimized string-searching algorithms, which can scan input FASTQ files to grab all reads that support target mutations. The collected supporting reads for each target mutation will be piled up and visualized using web technologies such as HTML and JavaScript. Algorithms such as rolling hash and bloom filter are applied to accelerate scanning and make MutScan applicable to detect or visualize target mutations in a very fast way. MutScan is a tool for the detection and visualization of target mutations by only scanning FASTQ raw data directly. Compared to conventional pipelines, this offers a very high performance, executing about 20 times faster, and offering maximal sensitivity since it can grab mutations with even one single supporting read. MutScan visualizes detected mutations by generating interactive pile-ups using web technologies. These can serve to validate target mutations, thus avoiding false positives. Furthermore, MutScan can visualize all mutation records in a VCF file to HTML pages for cloud-friendly VCF validation. MutScan is an open source tool available at GitHub: https://github.com/OpenGene/MutScan.

  11. Combining high-speed SVM learning with CNN feature encoding for real-time target recognition in high-definition video for ISR missions

    NASA Astrophysics Data System (ADS)

    Kroll, Christine; von der Werth, Monika; Leuck, Holger; Stahl, Christoph; Schertler, Klaus

    2017-05-01

    For Intelligence, Surveillance, Reconnaissance (ISR) missions of manned and unmanned air systems typical electrooptical payloads provide high-definition video data which has to be exploited with respect to relevant ground targets in real-time by automatic/assisted target recognition software. Airbus Defence and Space is developing required technologies for real-time sensor exploitation since years and has combined the latest advances of Deep Convolutional Neural Networks (CNN) with a proprietary high-speed Support Vector Machine (SVM) learning method into a powerful object recognition system with impressive results on relevant high-definition video scenes compared to conventional target recognition approaches. This paper describes the principal requirements for real-time target recognition in high-definition video for ISR missions and the Airbus approach of combining an invariant feature extraction using pre-trained CNNs and the high-speed training and classification ability of a novel frequency-domain SVM training method. The frequency-domain approach allows for a highly optimized implementation for General Purpose Computation on a Graphics Processing Unit (GPGPU) and also an efficient training of large training samples. The selected CNN which is pre-trained only once on domain-extrinsic data reveals a highly invariant feature extraction. This allows for a significantly reduced adaptation and training of the target recognition method for new target classes and mission scenarios. A comprehensive training and test dataset was defined and prepared using relevant high-definition airborne video sequences. The assessment concept is explained and performance results are given using the established precision-recall diagrams, average precision and runtime figures on representative test data. A comparison to legacy target recognition approaches shows the impressive performance increase by the proposed CNN+SVM machine-learning approach and the capability of real-time high-definition video exploitation.

  12. Fast photoacoustic imaging system based on 320-element linear transducer array.

    PubMed

    Yin, Bangzheng; Xing, Da; Wang, Yi; Zeng, Yaguang; Tan, Yi; Chen, Qun

    2004-04-07

    A fast photoacoustic (PA) imaging system, based on a 320-transducer linear array, was developed and tested on a tissue phantom. To reconstruct a test tomographic image, 64 time-domain PA signals were acquired from a tissue phantom with embedded light-absorption targets. A signal acquisition was accomplished by utilizing 11 phase-controlled sub-arrays, each consisting of four transducers. The results show that the system can rapidly map the optical absorption of a tissue phantom and effectively detect the embedded light-absorbing target. By utilizing the multi-element linear transducer array and phase-controlled imaging algorithm, we thus can acquire PA tomography more efficiently, compared to other existing technology and algorithms. The methodology and equipment thus provide a rapid and reliable approach to PA imaging that may have potential applications in noninvasive imaging and clinic diagnosis.

  13. A comparative study evaluating the efficacy of IS_MAP04 with IS900 and IS_MAP02 as a new diagnostic target for the detection of Mycobacterium avium subspecies paratuberculosis from bovine faeces.

    PubMed

    de Kruijf, Marcel; Govender, Rodney; Yearsley, Dermot; Coffey, Aidan; O'Mahony, Jim

    2017-05-01

    The aim of this study was to investigate the efficacy of IS_MAP04 as a potential new diagnostic quantitative PCR (qPCR) target for the detection of Mycobacterium avium subspecies paratuberculosis from bovine faeces. IS_MAP04 primers were designed and tested negative against non-MAP strains. The detection limit of IS_MAP04 qPCR was evaluated on different MAP K-10 DNA concentrations and on faecal samples spiked with different MAP K-10 cell dilutions. A collection of 106 faecal samples was analysed and the efficacy of IS_MAP04 was statistically compared with IS900 and IS_MAP02. The detection limits observed for IS_MAP04 and IS900 on MAP DNA was 34 fg and 3.4 fg respectively. The detection limit of MAP from inoculated faecal samples was 10 2 CFU/g for both IS_MAP04 and IS900 targets and a detection limit of 10 2 CFU/g was also achieved with a TaqMan qPCR targeting IS_MAP04. The efficacy of IS_MAP04 to detect positive MAP faecal samples was 83.0% compared to 85.8% and 83.9% for IS900 and IS_MAP02 respectively. Strong kappa agreements were observed between IS_MAP04 and IS900 (κ=0.892) and between IS_MAP04 and IS_MAP02 (κ=0.897). As a new molecular target, IS_MAP04 showed that the detection limit was comparable to IS900 to detect MAP from inoculated faecal material. The MAP detection efficacy of IS_MAP04 from naturally infected faecal samples proved to be relatively comparable to IS_MAP02, but yielded efficacy results slightly less than IS900. Moreover, IS_MAP04 could be of significant value when used in duplex or multiplex qPCR assays. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Adaptive target binarization method based on a dual-camera system

    NASA Astrophysics Data System (ADS)

    Lei, Jing; Zhang, Ping; Xu, Jiangtao; Gao, Zhiyuan; Gao, Jing

    2018-01-01

    An adaptive target binarization method based on a dual-camera system that contains two dynamic vision sensors was proposed. First, a preprocessing procedure of denoising is introduced to remove the noise events generated by the sensors. Then, the complete edge of the target is retrieved and represented by events based on an event mosaicking method. Third, the region of the target is confirmed by an event-to-event method. Finally, a postprocessing procedure of image open and close operations of morphology methods is adopted to remove the artifacts caused by event-to-event mismatching. The proposed binarization method has been extensively tested on numerous degraded images with nonuniform illumination, low contrast, noise, or light spots and successfully compared with other well-known binarization methods. The experimental results, which are based on visual and misclassification error criteria, show that the proposed method performs well and has better robustness on the binarization of degraded images.

  15. Head-Up Auditory Displays for Traffic Collision Avoidance System Advisories: A Preliminary Investigation

    NASA Technical Reports Server (NTRS)

    Begault, Durand R.

    1993-01-01

    The advantage of a head-up auditory display was evaluated in a preliminary experiment designed to measure and compare the acquisition time for capturing visual targets under two auditory conditions: standard one-earpiece presentation and two-earpiece three-dimensional (3D) audio presentation. Twelve commercial airline crews were tested under full mission simulation conditions at the NASA-Ames Man-Vehicle Systems Research Facility advanced concepts flight simulator. Scenario software generated visual targets corresponding to aircraft that would activate a traffic collision avoidance system (TCAS) aural advisory; the spatial auditory position was linked to the visual position with 3D audio presentation. Results showed that crew members using a 3D auditory display acquired targets approximately 2.2 s faster than did crew members who used one-earpiece head- sets, but there was no significant difference in the number of targets acquired.

  16. Cultural differences in the primacy effect for person perception.

    PubMed

    Noguchi, Kenji; Kamada, Akiko; Shrira, Ilan

    2014-06-01

    Previous work has shown there are robust differences in how North Americans and East Asians form impressions of people. The present research examines whether the tendency to weigh initial information more heavily-the primacy effect-may be another component of these cultural differences. Specifically, we tested whether Americans would be more likely to use first impressions to guide person perception, compared to Japanese participants. In this experiment, participants read a vignette that described a target person's behaviour, then rated the target's personality. Before reading the vignette, some trait information was given to create an expectation about the target's personality. The data revealed that Americans used this initial information to guide their judgments of the target, whereas the Japanese sample based their judgments on all the information more evenly. Thus, Americans showed a stronger primacy effect in their impression formation than Japanese participants, who engaged in more data-driven processing. © 2013 International Union of Psychological Science.

  17. The functional consequences of social distraction: Attention and memory for complex scenes.

    PubMed

    Doherty, Brianna Ruth; Patai, Eva Zita; Duta, Mihaela; Nobre, Anna Christina; Scerif, Gaia

    2017-01-01

    Cognitive scientists have long proposed that social stimuli attract visual attention even when task irrelevant, but the consequences of this privileged status for memory are unknown. To address this, we combined computational approaches, eye-tracking methodology, and individual-differences measures. Participants searched for targets in scenes containing social or non-social distractors equated for low-level visual salience. Subsequent memory precision for target locations was tested. Individual differences in autistic traits and social anxiety were also measured. Eye-tracking revealed significantly more attentional capture to social compared to non-social distractors. Critically, memory precision for target locations was poorer for social scenes. This effect was moderated by social anxiety, with anxious individuals remembering target locations better under conditions of social distraction. These findings shed further light onto the privileged attentional status of social stimuli and its functional consequences on memory across individuals. Copyright © 2016. Published by Elsevier B.V.

  18. [sgRNA design for the CRISPR/Cas9 system and evaluation of its off-target effects].

    PubMed

    Xie, Sheng-song; Zhang, Yi; Zhang, Li-sheng; Li, Guang-lei; Zhao, Chang-zhi; Ni, Pan; Zhao, Shu-hong

    2015-11-01

    The third generation of CRISPR/Cas9-mediated genome editing technology has been successfully applied to genome modification of various species including animals, plants and microorganisms. How to improve the efficiency of CRISPR/Cas9 genome editing and reduce its off-target effects has been extensively explored in this field. Using sgRNA (Small guide RNA) with high efficiency and specificity is one of the critical factors for successful genome editing. Several software have been developed for sgRNA design and/or off-target evaluation, which have advantages and disadvantages respectively. In this review, we summarize characters of 16 kinds online and standalone software for sgRNA design and/or off-target evaluation and conduct a comparative analysis of these different kinds of software through developing 38 evaluation indexes. We also summarize 11 experimental approaches for testing genome editing efficiency and off-target effects as well as how to screen highly efficient and specific sgRNA.

  19. Target discrimination method for SAR images based on semisupervised co-training

    NASA Astrophysics Data System (ADS)

    Wang, Yan; Du, Lan; Dai, Hui

    2018-01-01

    Synthetic aperture radar (SAR) target discrimination is usually performed in a supervised manner. However, supervised methods for SAR target discrimination may need lots of labeled training samples, whose acquirement is costly, time consuming, and sometimes impossible. This paper proposes an SAR target discrimination method based on semisupervised co-training, which utilizes a limited number of labeled samples and an abundant number of unlabeled samples. First, Lincoln features, widely used in SAR target discrimination, are extracted from the training samples and partitioned into two sets according to their physical meanings. Second, two support vector machine classifiers are iteratively co-trained with the extracted two feature sets based on the co-training algorithm. Finally, the trained classifiers are exploited to classify the test data. The experimental results on real SAR images data not only validate the effectiveness of the proposed method compared with the traditional supervised methods, but also demonstrate the superiority of co-training over self-training, which only uses one feature set.

  20. A study of the 200-metre fast walk test as a possible new assessment tool to predict maximal heart rate and define target heart rate for exercise training of coronary heart disease patients.

    PubMed

    Casillas, Jean-Marie; Joussain, Charles; Gremeaux, Vincent; Hannequin, Armelle; Rapin, Amandine; Laurent, Yves; Benaïm, Charles

    2015-02-01

    To develop a new predictive model of maximal heart rate based on two walking tests at different speeds (comfortable and brisk walking) as an alternative to a cardiopulmonary exercise test during cardiac rehabilitation. Evaluation of a clinical assessment tool. A Cardiac Rehabilitation Department in France. A total of 148 patients (133 men), mean age of 59 ±9 years, at the end of an outpatient cardiac rehabilitation programme. Patients successively performed a 6-minute walk test, a 200 m fast-walk test (200mFWT), and a cardiopulmonary exercise test, with measure of heart rate at the end of each test. An all-possible regression procedure was used to determine the best predictive regression models of maximal heart rate. The best model was compared with the Fox equation in term of predictive error of maximal heart rate using the paired t-test. Results of the two walking tests correlated significantly with maximal heart rate determined during the cardiopulmonary exercise test, whereas anthropometric parameters and resting heart rate did not. The simplified predictive model with the most acceptable mean error was: maximal heart rate = 130 - 0.6 × age + 0.3 × HR200mFWT (R(2) = 0.24). This model was superior to the Fox formula (R(2) = 0.138). The relationship between training target heart rate calculated from measured reserve heart rate and that established using this predictive model was statistically significant (r = 0.528, p < 10(-6)). A formula combining heart rate measured during a safe simple fast walk test and age is more efficient than an equation only including age to predict maximal heart rate and training target heart rate. © The Author(s) 2014.

  1. A configural dominant account of contextual cueing: Configural cues are stronger than colour cues.

    PubMed

    Kunar, Melina A; John, Rebecca; Sweetman, Hollie

    2014-01-01

    Previous work has shown that reaction times to find a target in displays that have been repeated are faster than those for displays that have never been seen before. This learning effect, termed "contextual cueing" (CC), has been shown using contexts such as the configuration of the distractors in the display and the background colour. However, it is not clear how these two contexts interact to facilitate search. We investigated this here by comparing the strengths of these two cues when they appeared together. In Experiment 1, participants searched for a target that was cued by both colour and distractor configural cues, compared with when the target was only predicted by configural information. The results showed that the addition of a colour cue did not increase contextual cueing. In Experiment 2, participants searched for a target that was cued by both colour and distractor configuration compared with when the target was only cued by colour. The results showed that adding a predictive configural cue led to a stronger CC benefit. Experiments 3 and 4 tested the disruptive effects of removing either a learned colour cue or a learned configural cue and whether there was cue competition when colour and configural cues were presented together. Removing the configural cue was more disruptive to CC than removing colour, and configural learning was shown to overshadow the learning of colour cues. The data support a configural dominant account of CC, where configural cues act as the stronger cue in comparison to colour when they are presented together.

  2. Conceptual Design and Dynamics Testing and Modeling of a Mars Tumbleweed Rover

    NASA Technical Reports Server (NTRS)

    Calhoun Philip C.; Harris, Steven B.; Raiszadeh, Behzad; Zaleski, Kristina D.

    2005-01-01

    The NASA Langley Research Center has been developing a novel concept for a Mars planetary rover called the Mars Tumbleweed. This concept utilizes the wind to propel the rover along the Mars surface, bringing it the potential to cover vast distances not possible with current Mars rover technology. This vehicle, in its deployed configuration, must be large and lightweight to provide the ratio of drag force to rolling resistance necessary to initiate motion from rest on the Mars surface. One Tumbleweed design concept that satisfies these considerations is called the Eggbeater-Dandelion. This paper describes the basic design considerations and a proposed dynamics model of the concept for use in simulation studies. It includes a summary of rolling/bouncing dynamics tests that used videogrammetry to better understand, characterize, and validate the dynamics model assumptions, especially the effective rolling resistance in bouncing/rolling dynamic conditions. The dynamics test used cameras to capture the motion of 32 targets affixed to a test article s outer structure. Proper placement of the cameras and alignment of their respective fields of view provided adequate image resolution of multiple targets along the trajectory as the test article proceeded down the ramp. Image processing of the frames from multiple cameras was used to determine the target positions. Position data from a set of these test runs was compared with results of a three dimensional, flexible dynamics model. Model input parameters were adjusted to match the test data for runs conducted. This process presented herein provided the means to characterize the dynamics and validate the simulation of the Eggbeater-Dandelion concept. The simulation model was used to demonstrate full scale Tumbleweed motion from a stationary condition on a flat-sloped terrain using representative Mars environment parameters.

  3. Recommendations for a step‐wise comparative approach to the evaluation of new screening tests for colorectal cancer

    PubMed Central

    Senore, Carlo; Mandel, Jack S.; Allison, James E.; Atkin, Wendy S.; Benamouzig, Robert; Bossuyt, Patrick M. M.; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P.; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H.; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A.; O'Morain, Colm A.; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E.; Seaman, Helen E.; Steele, Robert J. C.; Sung, Joseph J. Y.; Winawer, Sidney J.

    2016-01-01

    BACKGROUND New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. METHODS A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. RESULTS Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention‐to‐screen basis, including acceptability, is essential. Cancer‐specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac‐based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4‐phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention‐to‐screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true‐positive and false‐positive rates, and the number needed to colonoscope to detect a target lesion. CONCLUSIONS New screening tests can be evaluated efficiently by this stepwise comparative approach. Cancer 2016;122:826–39. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society. PMID:26828588

  4. Recommendations for a step-wise comparative approach to the evaluation of new screening tests for colorectal cancer.

    PubMed

    Young, Graeme P; Senore, Carlo; Mandel, Jack S; Allison, James E; Atkin, Wendy S; Benamouzig, Robert; Bossuyt, Patrick M M; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A; O'Morain, Colm A; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E; Seaman, Helen E; Steele, Robert J C; Sung, Joseph J Y; Winawer, Sidney J

    2016-03-15

    New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention-to-screen basis, including acceptability, is essential. Cancer-specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac-based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4-phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention-to-screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true-positive and false-positive rates, and the number needed to colonoscope to detect a target lesion. New screening tests can be evaluated efficiently by this stepwise comparative approach. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society.

  5. Positive-pressure ventilation during transport: a randomized crossover study of self-inflating and flow-inflating resuscitators in a simulation model.

    PubMed

    Lucy, Malcolm J; Gamble, Jonathan J; Daku, Brian L; Bryce, Rhonda D; Rana, Masud

    2014-12-01

    Positive-pressure ventilation during transport of intubated patients is generally delivered via a hand-pressurized device. Of these devices, self-inflating resuscitators (SIR) and flow-inflating resuscitators (FIR) constitute the two major types used. Selection of a particular device for transport, however, remains largely an institutional practice. To evaluate the hypothesis that transport ventilation goals of intubated pediatric patients are better achieved using an FIR compared to an SIR. This randomized crossover simulation study compared the performance of SIR and FIR among anesthesia providers in a pediatric transport scenario. Subjects hand-ventilated a test lung while simultaneously maneuvering a stretcher bed to simulate patient transport. Hand ventilation was carried out using a Jackson-Rees circuit (FIR) and a Laerdal pediatric silicone resuscitator (SIR). The primary outcome was the proportion of total breaths delivered within the predefined target PIP/PEEP range (30+/- 3, 10+/- 3 cm H2O). Secondary outcomes included proportion of total breaths delivered with operationally defined unacceptable breath variables (PIP > 35 cm H2O or PEEP < 5 cm H2O). Overall, participants were four times more likely to deliver target breaths and one-third less likely to deliver unacceptable breaths using the FIR compared to the SIR. When comparing device performance, a 44% increase in the proportions of target breaths and a 40.4% decrease in unacceptable breaths using the FIR were observed (P < 0.0001 for both). Hand ventilation during patient transport is superior using the FIR compared to the SIR to achieve target ventilatory goals and avoid unacceptable ventilatory cycles. © 2014 John Wiley & Sons Ltd.

  6. STAR Au + Au Fixed Target Results

    NASA Astrophysics Data System (ADS)

    Meehan, Kathryn; STAR Collaboration

    2015-10-01

    The RHIC Beam Energy Scan (BES) program was proposed to look for the turn-off of signatures of the quark gluon plasma (QGP), search for a possible QCD critical point, and study the nature of the phase transition between hadronic and partonic matter. The results from the NA49 experiment at CERN have been used to claim that the onset of deconfinement occurs at a collision energy around a center-of-mass energy of 7 GeV, the low end of the BES range. Data from lower energies are needed to test if this onset occurs. The goal of the STAR Fixed-Target Program is to extend the collision energy range in BES II with the same detector to energies that are likely below the onset of deconfinement. Currently, STAR has inserted a gold target into the beam pipe and conducted test runs at center-of-mass energies 3.9 and 4.5 GeV. Tests have been done with both Au and Al beams. First physics results from a Coulomb analysis of Au + Au fixed-target collisions, which are found to be consistent with previous experiments, will be presented. These results demonstrate that STAR has good particle identification capabilities in this novel detector setup. Furthermore, the Coulomb potential, which is sensitive to the Z of the projectile and degree of baryonic stopping, will be compared with published results from the AGS. This material is based upon work supported by the National Science Foundation under Grant No. 1068833.

  7. Machine learning and docking models for Mycobacterium tuberculosis topoisomerase I.

    PubMed

    Ekins, Sean; Godbole, Adwait Anand; Kéri, György; Orfi, Lászlo; Pato, János; Bhat, Rajeshwari Subray; Verma, Rinkee; Bradley, Erin K; Nagaraja, Valakunja

    2017-03-01

    There is a shortage of compounds that are directed towards new targets apart from those targeted by the FDA approved drugs used against Mycobacterium tuberculosis. Topoisomerase I (Mttopo I) is an essential mycobacterial enzyme and a promising target in this regard. However, it suffers from a shortage of known inhibitors. We have previously used computational approaches such as homology modeling and docking to propose 38 FDA approved drugs for testing and identified several active molecules. To follow on from this, we now describe the in vitro testing of a library of 639 compounds. These data were used to create machine learning models for Mttopo I which were further validated. The combined Mttopo I Bayesian model had a 5 fold cross validation receiver operator characteristic of 0.74 and sensitivity, specificity and concordance values above 0.76 and was used to select commercially available compounds for testing in vitro. The recently described crystal structure of Mttopo I was also compared with the previously described homology model and then used to dock the Mttopo I actives norclomipramine and imipramine. In summary, we describe our efforts to identify small molecule inhibitors of Mttopo I using a combination of machine learning modeling and docking studies in conjunction with screening of the selected molecules for enzyme inhibition. We demonstrate the experimental inhibition of Mttopo I by small molecule inhibitors and show that the enzyme can be readily targeted for lead molecule development. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Target innervation is necessary for neuronal polyploidization in the terrestrial slug Limax.

    PubMed

    Matsuo, Ryota; Yamagishi, Miki; Wakiya, Kyoko; Tanaka, Yoko; Ito, Etsuro

    2013-08-01

    The brain of gastropod mollusks contains many giant neurons with polyploid genomic DNAs. Such DNAs are generated through repeated DNA endoreplication during body growth. However, it is not known what triggers DNA endoreplication in neurons. There are two possibilities: (1) DNAs are replicated in response to some unknown molecules in the hemolymph that reflect the nutritive status of the animal; or (2) DNAs are replicated in response to some unknown factors that are retrogradely transported through axons from the innervated target organs. We first tested whether hemolymph with rich nutrition could induce DNA endoreplication. We tested whether the transplanted brain exhibits enhanced DNA endoreplication like an endogenous brain does when transplanted into the homocoel of the body of a slug whose body growth is promoted by an increased food supply. However, no enhancement was observed in the frequency of DNA endoreplication when we compared the transplanted brains in the growth-promoted and growth-suppressed host slugs, suggesting that the humoral environment is irrelevant to triggering the body growth-dependent DNA endoreplication. Next, we tested the requirement of target innervation by surgically dissecting a unilateral posterior pedal nerve of an endogenous brain. Substantially lower number of neurons exhibited DNA endoreplication in the pedal ganglion ipsilateral to the dissected nerve. These results support the view that enhanced DNA endoreplication is mediated by target innervation and is not brought about through the direct effect of humoral factors in the hemolymph during body growth. Copyright © 2013 Wiley Periodicals, Inc.

  9. Comparison of a Stimulus Equivalence Protocol and Traditional Lecture for Teaching Single-Subject Designs

    ERIC Educational Resources Information Center

    Lovett, Sadie; Rehfeldt, Ruth Anne; Garcia, Yors; Dunning, Johnna

    2011-01-01

    This study compared the effects of a computer-based stimulus equivalence protocol to a traditional lecture format in teaching single-subject experimental design concepts to undergraduate students. Participants were assigned to either an equivalence or a lecture group, and performance on a paper-and-pencil test that targeted relations among the…

  10. Appropriate targeting of artemisinin-based combination therapy by community health workers using malaria rapid diagnostic tests: findings from randomized trials in two contrasting areas of high and low malaria transmission in south-western Uganda.

    PubMed

    Ndyomugyenyi, Richard; Magnussen, Pascal; Lal, Sham; Hansen, Kristian; Clarke, Siân E

    2016-09-01

    To compare the impact of malaria rapid diagnostic tests (mRDTs), used by community health workers (CHWs), on the proportion of children <5 years of age receiving appropriately targeted treatment with artemisinin-based combination therapy (ACT), vs. presumptive treatment. Cluster-randomized trials were conducted in two contrasting areas of moderate-to-high and low malaria transmission in rural Uganda. Each trial examined the effectiveness of mRDTs in the management of malaria and targeting of ACTs by CHWs comparing two diagnostic approaches: (i) presumptive clinical diagnosis of malaria [control arm] and (ii) confirmatory diagnosis with mRDTs followed by ACT treatment for positive patients [intervention arm], with village as the unit of randomisation. Treatment decisions by CHWs were validated by microscopy on a reference blood slide collected at the time of consultation, to compare the proportion of children <5 years receiving appropriately targeted ACT treatment, defined as patients with microscopically-confirmed presence of parasites in a peripheral blood smear receiving artemether-lumefantrine or rectal artesunate, and patients with no malaria parasites not given ACT. In the moderate-to-high transmission area, ACT treatment was appropriately targeted in 79.3% (520/656) of children seen by CHWs using mRDTs to diagnose malaria, vs. 30.8% (215/699) of children seen by CHWs using presumptive diagnosis (P < 0.001). In the low transmission area, 90.1% (363/403) children seen by CHWs using mRDTs received appropriately targeted ACT treatment vs. 7.8% (64/817) seen by CHWs using presumptive diagnosis (P < 0.001). Low mRDT sensitivity in children with low-density parasitaemia (<200 parasites/μl) was identified as a potential concern. When equipped with mRDTs, ACT treatments delivered by CHWs are more accurately targeted to children with malaria parasites. mRDT use could play an important role in reducing overdiagnosis of malaria and improving fever case management within iCCM, in both moderate-to-high and low transmission areas. Nonetheless, missed treatments due to the low sensitivity of current mRDTs in patients with low parasite density are a concern. For community-based treatment in areas of low transmission and/or non-immune populations, presumptive treatment of all fevers as malaria may be advisable, until more sensitive diagnostic assays, suitable for routine use by CHWs in remote settings, become available. © 2016 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  11. International Standards on stability of digital prints

    NASA Astrophysics Data System (ADS)

    Adelstein, Peter Z.

    2010-06-01

    The International Standards Organization (ISO) is a worldwide recognized standardizing body which has responsibility for standards on permanence of digital prints. This paper is an update on the progress made to date by ISO in writing test methods in this area. Three technologies are involved, namely ink jet, dye diffusion thermal transfer (dye-sublimation) and electrophotography. Two types of test methods are possible, namely comparative tests and predictive tests. To date a comparative test on water fastness has been published and final balloting is underway on a comparative test on humidity fastness. Predictive tests are being finalized on thermal stability and pollution susceptibility. The test method on thermal stability is intended to predict the print life during normal aging. One of the testing concerns is that some prints do not show significant image change in practical testing times. The test method on pollution susceptibility only deals with ozone and assumes that the reciprocity law applies. This law assumes that a long time under a low pollutant concentration is equivalent to a short time under the high concentration used in the test procedure. Longer term studies include a predictive test for light stability and the preparation of a material specification. The latter requires a decision about the proper colour target to be used and what constitutes an unacceptable colour change. Moreover, a specification which gives a predictive life is very dependent upon the conditions the print encounters and will only apply to specific levels of temperature, ozone and light.

  12. Development of electrochemical biosensor for detection of pathogenic microorganism in Asian dust events.

    PubMed

    Yoo, Min-Sang; Shin, Minguk; Kim, Younghun; Jang, Min; Choi, Yoon-E; Park, Si Jae; Choi, Jonghoon; Lee, Jinyoung; Park, Chulhwan

    2017-05-01

    We developed a single-walled carbon nanotubes (SWCNTs)-based electrochemical biosensor for the detection of Bacillus subtilis, one of the microorganisms observed in Asian dust events, which causes respiratory diseases such as asthma and pneumonia. SWCNTs plays the role of a transducer in biological antigen/antibody reaction for the electrical signal while 1-pyrenebutanoic acid succinimidyl ester (1-PBSE) and ant-B. subtilis were performed as a chemical linker and an acceptor, respectively, for the adhesion of target microorganism in the developed biosensor. The detection range (10 2 -10 10  CFU/mL) and the detection limit (10 2  CFU/mL) of the developed biosensor were identified while the response time was 10 min. The amount of target B. subtilis was the highest in the specificity test of the developed biosensor, compared with the other tested microorganisms (Staphylococcus aureus, Flavobacterium psychrolimnae, and Aquabacterium commune). In addition, target B. subtilis detected by the developed biosensor was observed by scanning electron microscope (SEM) analysis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Testing implications of varying targets for Bordetella pertussis: comparison of the FilmArray Respiratory Panel and the Focus B. pertussis PCR assay

    PubMed Central

    Jerris, Robert C; Williams, Sally R; MacDonald, Heather J; Ingebrigtsen, Danielle R; Westblade, Lars F; Rogers, Beverly B

    2015-01-01

    Background The FilmArray Respiratory Panel (RP) detects multiple pathogens, including Bordetella pertussis. The multiplex PCR system is appropriate for a core laboratory or point of care due to ease of use. The purpose of this study is to compare the analytical sensitivity of the FilmArray RP, which targets the promoter region of the B. pertussis toxin gene, with the Focus real-time PCR assay, which targets the insertion sequence IS481. Methods Seventy-one specimens from patients aged 1 month to 18 years, which had tested positive for B. pertussis using the Focus assay, were analysed using the FilmArray RP. Results Forty-six specimens were positive for B. pertussis by both the Focus and the FilmArray RP assays. Twenty-five specimens were negative for B. pertussis using the FilmArray RP assay, but positive using the Focus assay. Conclusions The FilmArray RP assays will detect approximately 1/3 less cases of B. pertussis than the Focus assay. PMID:25742911

  14. Effect of advanced nanowire-based targets in nanosecond laser-matter interaction (invited)

    NASA Astrophysics Data System (ADS)

    Lanzalone, G.; Altana, C.; Mascali, D.; Muoio, A.; Malferrari, L.; Odorici, F.; Malandrino, G.; Tudisco, S.

    2016-02-01

    An experimental campaign aiming to investigate the effects of innovative nanostructured targets based on Ag nanowires on laser energy absorption in the ns time domain has been carried out at the Laser Energy for Nuclear Science laboratory of INFN-LNS in Catania. The tested targets were realized at INFN-Bologna by anodizing aluminium sheets in order to obtain layers of porous Al2O3 of different thicknesses, on which nanowires of various metals are grown by electro-deposition with different heights. Targets were then irradiated by using a Nd:YAG laser at different pumping energies. Advanced diagnostic tools were used for characterizing the plasma plume and ion production. As compared with targets of pure Al, a huge enhancement (of almost two order of magnitude) of the X-ray flux emitted by the plasma has been observed when using the nanostructured targets, with a corresponding decrease of the "optical range" signal, pointing out that the energetic content of the laser produced plasma was remarkably increased. This analysis was furthermore confirmed from time-of-flight spectra.

  15. Effect of advanced nanowire-based targets in nanosecond laser-matter interaction (invited).

    PubMed

    Lanzalone, G; Altana, C; Mascali, D; Muoio, A; Malferrari, L; Odorici, F; Malandrino, G; Tudisco, S

    2016-02-01

    An experimental campaign aiming to investigate the effects of innovative nanostructured targets based on Ag nanowires on laser energy absorption in the ns time domain has been carried out at the Laser Energy for Nuclear Science laboratory of INFN-LNS in Catania. The tested targets were realized at INFN-Bologna by anodizing aluminium sheets in order to obtain layers of porous Al2O3 of different thicknesses, on which nanowires of various metals are grown by electro-deposition with different heights. Targets were then irradiated by using a Nd:YAG laser at different pumping energies. Advanced diagnostic tools were used for characterizing the plasma plume and ion production. As compared with targets of pure Al, a huge enhancement (of almost two order of magnitude) of the X-ray flux emitted by the plasma has been observed when using the nanostructured targets, with a corresponding decrease of the "optical range" signal, pointing out that the energetic content of the laser produced plasma was remarkably increased. This analysis was furthermore confirmed from time-of-flight spectra.

  16. Targeting the human epidermal growth factor receptor 2 (HER2) oncogene in colorectal cancer

    PubMed Central

    Siena, S; Sartore-Bianchi, A; Marsoni, S; Hurwitz, H I; McCall, S J; Penault-Llorca, F; Srock, S; Bardelli, A; Trusolino, L

    2018-01-01

    Abstract Human epidermal growth factor receptor 2 (HER2) is an oncogenic driver, and a well-established therapeutic target in breast and gastric cancers. Using functional and genomic analyses of patient-derived xenografts, we previously showed that a subset (approximately 5%) of metastatic colorectal cancer (CRC) tumors is driven by amplification or mutation of HER2. This paper reviews the role of HER2 amplification as an oncogenic driver, a prognostic and predictive biomarker, and a clinically actionable target in CRC, considering the specifics of HER2 testing in this tumor type. While the role of HER2 as a biomarker for prognosis in CRC remains uncertain, its relevance as a therapeutic target has been established. Indeed, independent studies documented substantial clinical benefit in patients treated with biomarker-driven HER2-targeted therapies, with an impact on response rates and duration of response that compared favorably with immunotherapy and other examples of precision oncology. HER2-targeted therapeutic strategies have the potential to change the treatment paradigm for a clinically relevant subgroup of metastatic CRC patients. PMID:29659677

  17. Effect of advanced nanowire-based targets in nanosecond laser-matter interaction (invited)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lanzalone, G., E-mail: Gaetano.Lanzalone@ct.infn.it; Università degli Studi di Enna “Kore,” Via delle Olimpiadi, 94100 Enna; Altana, C.

    2016-02-15

    An experimental campaign aiming to investigate the effects of innovative nanostructured targets based on Ag nanowires on laser energy absorption in the ns time domain has been carried out at the Laser Energy for Nuclear Science laboratory of INFN-LNS in Catania. The tested targets were realized at INFN-Bologna by anodizing aluminium sheets in order to obtain layers of porous Al{sub 2}O{sub 3} of different thicknesses, on which nanowires of various metals are grown by electro-deposition with different heights. Targets were then irradiated by using a Nd:YAG laser at different pumping energies. Advanced diagnostic tools were used for characterizing the plasmamore » plume and ion production. As compared with targets of pure Al, a huge enhancement (of almost two order of magnitude) of the X-ray flux emitted by the plasma has been observed when using the nanostructured targets, with a corresponding decrease of the “optical range” signal, pointing out that the energetic content of the laser produced plasma was remarkably increased. This analysis was furthermore confirmed from time-of-flight spectra.« less

  18. Eliminating the mere exposure effect through changes in context between exposure and test.

    PubMed

    de Zilva, Daniel; Mitchell, Chris J; Newell, Ben R

    2013-01-01

    The present study examined the extent to which increased liking of exposed stimuli--the mere exposure effect--is dependent on experiencing the stimuli in the same context in exposure and on test. Participants were repeatedly exposed to pairs of cues (nonsense words) and target stimuli (faces and shapes), and were asked to rate the pleasantness of the target stimuli in a subsequent test phase. Familiar targets were preferred to novel targets-a mere exposure effect was obtained. This preference for familiar targets was disrupted, however, when the cue-target pairings were rearranged between exposure and test, or a novel cue was introduced at test. Overall, the study suggests that the context of exposure and test moderates the mere exposure effect. Liking of stimuli due to exposure is specific to the context of exposure and does not apply to new or familiar but different contexts.

  19. Should trained lay providers perform HIV testing? A systematic review to inform World Health Organization guidelines.

    PubMed

    Kennedy, C E; Yeh, P T; Johnson, C; Baggaley, R

    2017-12-01

    New strategies for HIV testing services (HTS) are needed to achieve UN 90-90-90 targets, including diagnosis of 90% of people living with HIV. Task-sharing HTS to trained lay providers may alleviate health worker shortages and better reach target groups. We conducted a systematic review of studies evaluating HTS by lay providers using rapid diagnostic tests (RDTs). Peer-reviewed articles were included if they compared HTS using RDTs performed by trained lay providers to HTS by health professionals, or to no intervention. We also reviewed data on end-users' values and preferences around lay providers preforming HTS. Searching was conducted through 10 online databases, reviewing reference lists, and contacting experts. Screening and data abstraction were conducted in duplicate using systematic methods. Of 6113 unique citations identified, 5 studies were included in the effectiveness review and 6 in the values and preferences review. One US-based randomized trial found patients' uptake of HTS doubled with lay providers (57% vs. 27%, percent difference: 30, 95% confidence interval: 27-32, p < 0.001). In Malawi, a pre/post study showed increases in HTS sites and tests after delegation to lay providers. Studies from Cambodia, Malawi, and South Africa comparing testing quality between lay providers and laboratory staff found little discordance and high sensitivity and specificity (≥98%). Values and preferences studies generally found support for lay providers conducting HTS, particularly in non-hypothetical scenarios. Based on evidence supporting using trained lay providers, a WHO expert panel recommended lay providers be allowed to conduct HTS using HIV RDTs. Uptake of this recommendation could expand HIV testing to more people globally.

  20. Single-breath diffusing capacity for carbon monoxide instrument accuracy across 3 health systems.

    PubMed

    Hegewald, Matthew J; Markewitz, Boaz A; Wilson, Emily L; Gallo, Heather M; Jensen, Robert L

    2015-03-01

    Measuring diffusing capacity of the lung for carbon monoxide (DLCO) is complex and associated with wide intra- and inter-laboratory variability. Increased D(LCO) variability may have important clinical consequences. The objective of the study was to assess instrument performance across hospital pulmonary function testing laboratories using a D(LCO) simulator that produces precise and repeatable D(LCO) values. D(LCO) instruments were tested with CO gas concentrations representing medium and high range D(LCO) values. The absolute difference between observed and target D(LCO) value was used to determine measurement accuracy; accuracy was defined as an average deviation from the target value of < 2.0 mL/min/mm Hg. Accuracy of inspired volume measurement and gas sensors were also determined. Twenty-three instruments were tested across 3 healthcare systems. The mean absolute deviation from the target value was 1.80 mL/min/mm Hg (range 0.24-4.23) with 10 of 23 instruments (43%) being inaccurate. High volume laboratories performed better than low volume laboratories, although the difference was not significant. There was no significant difference among the instruments by manufacturers. Inspired volume was not accurate in 48% of devices; mean absolute deviation from target value was 3.7%. Instrument gas analyzers performed adequately in all instruments. D(LCO) instrument accuracy was unacceptable in 43% of devices. Instrument inaccuracy can be primarily attributed to errors in inspired volume measurement and not gas analyzer performance. D(LCO) instrument performance may be improved by regular testing with a simulator. Caution should be used when comparing D(LCO) results reported from different laboratories. Copyright © 2015 by Daedalus Enterprises.

  1. A Dosimetric Comparison of Breast Radiotherapy Techniques to Treat Locoregional Lymph Nodes Including the Internal Mammary Chain.

    PubMed

    Ranger, A; Dunlop, A; Hutchinson, K; Convery, H; Maclennan, M K; Chantler, H; Twyman, N; Rose, C; McQuaid, D; Amos, R A; Griffin, C; deSouza, N M; Donovan, E; Harris, E; Coles, C E; Kirby, A

    2018-06-01

    Radiotherapy target volumes in early breast cancer treatment increasingly include the internal mammary chain (IMC). In order to maximise survival benefits of IMC radiotherapy, doses to the heart and lung should be minimised. This dosimetry study compared the ability of three-dimensional conformal radiotherapy, arc therapy and proton beam therapy (PBT) techniques with and without breath-hold to achieve target volume constraints while minimising dose to organs at risk (OARs). In 14 patients' datasets, seven IMC radiotherapy techniques were compared: wide tangent (WT) three-dimensional conformal radiotherapy, volumetric-modulated arc therapy (VMAT) and PBT, each in voluntary deep inspiratory breath-hold (vDIBH) and free breathing (FB), and tomotherapy in FB only. Target volume coverage and OAR doses were measured for each technique. These were compared using a one-way ANOVA with all pairwise comparisons tested using Bonferroni's multiple comparisons test, with adjusted P-values ≤ 0.05 indicating statistical significance. One hundred per cent of WT(vDIBH), 43% of WT(FB), 100% of VMAT(vDIBH), 86% of VMAT(FB), 100% of tomotherapy FB and 100% of PBT plans in vDIBH and FB passed all mandatory constraints. However, coverage of the IMC with 90% of the prescribed dose was significantly better than all other techniques using VMAT(vDIBH), PBT(vDIBH) and PBT(FB) (mean IMC coverage ± 1 standard deviation = 96.0% ± 4.3, 99.8% ± 0.3 and 99.0% ± 0.2, respectively). The mean heart dose was significantly reduced in vDIBH compared with FB for both the WT (P < 0.0001) and VMAT (P < 0.0001) techniques. There was no advantage in target volume coverage or OAR doses for PBT(vDIBH) compared with PBT(FB). Simple WT radiotherapy delivered in vDIBH achieves satisfactory coverage of the IMC while meeting heart and lung dose constraints. However, where higher isodose coverage is required, VMAT(vDIBH) is the optimal photon technique. The lowest OAR doses are achieved by PBT, in which the use of vDIBH does not improve dose statistics. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  2. Research on the strategy of underwater united detection fusion and communication using multi-sensor

    NASA Astrophysics Data System (ADS)

    Xu, Zhenhua; Huang, Jianguo; Huang, Hai; Zhang, Qunfei

    2011-09-01

    In order to solve the distributed detection fusion problem of underwater target detection, when the signal to noise ratio (SNR) of the acoustic channel is low, a new strategy for united detection fusion and communication using multiple sensors was proposed. The performance of detection fusion was studied and compared based on the Neyman-Pearson principle when the binary phase shift keying (BPSK) and on-off keying (OOK) modes were used by the local sensors. The comparative simulation and analysis between the optimal likelihood ratio test and the proposed strategy was completed, and both the theoretical analysis and simulation indicate that using the proposed new strategy could improve the detection performance effectively. In theory, the proposed strategy of united detection fusion and communication is of great significance to the establishment of an underwater target detection system.

  3. Words, shape, visual search and visual working memory in 3-year-old children.

    PubMed

    Vales, Catarina; Smith, Linda B

    2015-01-01

    Do words cue children's visual attention, and if so, what are the relevant mechanisms? Across four experiments, 3-year-old children (N = 163) were tested in visual search tasks in which targets were cued with only a visual preview versus a visual preview and a spoken name. The experiments were designed to determine whether labels facilitated search times and to examine one route through which labels could have their effect: By influencing the visual working memory representation of the target. The targets and distractors were pictures of instances of basic-level known categories and the labels were the common name for the target category. We predicted that the label would enhance the visual working memory representation of the target object, guiding attention to objects that better matched the target representation. Experiments 1 and 2 used conjunctive search tasks, and Experiment 3 varied shape discriminability between targets and distractors. Experiment 4 compared the effects of labels to repeated presentations of the visual target, which should also influence the working memory representation of the target. The overall pattern fits contemporary theories of how the contents of visual working memory interact with visual search and attention, and shows that even in very young children heard words affect the processing of visual information. © 2014 John Wiley & Sons Ltd.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Varinderjit; Vadas, J.; Steinbach, T. K.

    Measuring the fusion excitation function for an isotopic chain of projectile nuclei provides a stringent test of a microscopic description of fusion. We report the first measurement of the fusion excitation function at near-barrier energies for the 19O+ 12C system. The measured excitation function is compared with the fusion excitation function of 18O+ 12C. A significant enhancement in the fusion probability of 19O ions with a 12C target as compared to 18O ions is observed. As a result, the experimental cross-sections observed at near-barrier energies are compared with a state-of-the-art microscopic model.

  5. Sustaining quality in the community: trends in the performance of a structured diabetes care programme in primary care over 16 years.

    PubMed

    Riordan, F; McHugh, S M; Harkins, V; Marsden, P; Kearney, P M

    2018-04-29

    To examine the quality of care delivered by a structured primary care-led programme for people with Type 2 diabetes mellitus in 1999-2016. The Midland Diabetes Structured Care Programme provides structured primary care-led management. Trends over time in care processes were examined (using a chi-squared trend test and age- and gender-adjusted logistic regression). Screening and annual review attendance were reviewed. A composite of eight National Institute for Health and Care Excellence-recommended processes was used as a quality indicator. Participants who were referred to diabetes nurse specialists were compared with those not referred (Student's t-test, Pearson's chi-squared test, Wilcoxon-Mann-Whitney test). Proportions achieving outcome targets [HbA 1c ≤58 mmol/mol (7.5%), blood pressure ≤140/80 mmHg, cholesterol <5.0 mmol/l] were calculated. Data were available for people with diabetes aged ≥18 years: 1998/1999 (n=336); 2003 (n=843); 2008 (n=988); and 2016 (n=1029). Recording of some processes improved significantly over time (HbA 1c , cholesterol, blood pressure, creatinine), and in 2016 exceeded 97%. Foot assessment and annual review attendance declined. In 2016, only 29% of participants had all eight National Institute for Health and Care Excellence processes recorded. A higher proportion of people with diabetes who were referred to a diabetes nurse specialist had poor glycaemic control compared with those not referred. The proportions meeting blood pressure and lipid targets increased over time. Structured primary care led to improvements in the quality of care over time. Poorer recording of some processes, a decline in annual review attendance, and participants remaining at high risk suggest limits to what structured care alone can achieve. Engagement in continuous quality improvement to target other factors, including attendance and self-management, may deliver further improvements. © 2018 Diabetes UK.

  6. Targeted erlotinib for first-line treatment of advanced non-small cell lung cancer: a budget impact analysis.

    PubMed

    Bajaj, Preeti S; Veenstra, David L; Goertz, Hans-Peter; Carlson, Josh J

    2014-08-01

    A recent phase III trial showed that patients with advanced non-small cell lung cancer (NSCLC) whose tumors harbor specific EGFR mutations significantly benefit from first-line treatment with erlotinib compared to chemotherapy. This study sought to estimate the budget impact if coverage for EGFR testing and erlotinib as first-line therapy were provided in a hypothetical 500,000-member managed care plan. The budget impact model was developed from a US health plan perspective to evaluate administration of the EGFR test and treatment with erlotinib for EGFR-positive patients, compared to non-targeted treatment with chemotherapy. The eligible patient population was estimated from age-stratified SEER incidence data. Clinical data were derived from key randomized controlled trials. Costs related to drug, administration, and adverse events were included. Sensitivity analyses were conducted to assess uncertainty. In a plan of 500,000 members, it was estimated there would be 91 newly diagnosed advanced NSCLC patients annually; 11 are expected to be EGFR-positive. Based on the testing and treatment assumptions, it was estimated that 3 patients in Scenario 1 and 6 patients in Scenario 2 receive erlotinib. Overall health plan expenditures would increase by $0.013 per member per month (PMPM). This increase is largely attributable to erlotinib drug costs, in part due to lengthened progression-free survival and treatment periods experienced in erlotinib-treated patients. EGFR testing contributes slightly, whereas adverse event costs mitigate the budget impact. The budget impact did not exceed $0.019 PMPM in sensitivity analyses. Coverage for targeted first-line erlotinib therapy in NSCLC likely results in a small budget impact for US health plans. The estimated impact may vary by plan, or if second-line or maintenance therapy, dose changes/interruptions, or impact on patients' quality-of-life were included.

  7. MRI directed bilateral stimulation of the subthalamic nucleus in patients with Parkinson's disease

    PubMed Central

    Patel, N; Plaha, P; O'Sullivan, K; McCarter, R; Heywood, P; Gill, S

    2003-01-01

    Objective: Bilateral chronic high frequency deep brain stimulation (DBS) of the subthalamic nucleus (STN) has emerged as an appropriate therapy for patients with advanced Parkinson's disease refractory to medical therapy. Advances in neuroimaging and neurophysiology have led to the development of varied targeting methods for the delivery of this treatment. Intraoperative neurophysiological and clinical monitoring is regarded by many to be mandatory for accurate STN localisation. We have examined efficacy of bilateral STN stimulation using a predominantly magnetic resonance imaging (MRI)-directed technique. Methods: DBS leads were stereotactically implanted into the STN using an MRI directed method, with intraoperative macrostimulation used purely for adjustment. The effects of DBS were evaluated in 16 patients followed up to 12 months, and compared with baseline assessments. Assessments were performed in both off and on medication states, and were based on the Unified Parkinson's Disease Rating Scale (UPDRS) and timed motor tests. Functional status outcomes were examined using the PDQ-39 quality of life questionnaire. A battery of psychometric tests was used to assess cognition. Results: After 12 months, stimulation in the off medication state resulted in significant improvements in Activities of Daily Living and Motor scores (UPDRS parts II and III) by 62% and 61% respectively. Timed motor tests were significantly improved in the off medication state. Motor scores (UPDRS part III) were significantly improved by 40% in the on medication state. Dyskinesias and off duration were significantly reduced and the mean dose of L-dopa equivalents was reduced by half. Psychometric test scores were mostly unchanged or improved. Adverse events were few. Conclusions: An MRI directed targeting method for implantation of DBS leads into the STN can be used safely and effectively, and results are comparable with studies using intraoperative microelectrode neurophysiological targeting. In addition, our method was associated with an efficient use of operating time, and without the necessary costs of microelectrode recording. PMID:14638880

  8. Combination of blood tests for significant fibrosis and cirrhosis improves the assessment of liver-prognosis in chronic hepatitis C.

    PubMed

    Boursier, J; Brochard, C; Bertrais, S; Michalak, S; Gallois, Y; Fouchard-Hubert, I; Oberti, F; Rousselet, M-C; Calès, P

    2014-07-01

    Recent longitudinal studies have emphasised the prognostic value of noninvasive tests of liver fibrosis and cross-sectional studies have shown their combination significantly improves diagnostic accuracy. To compare the prognostic accuracy of six blood fibrosis tests and liver biopsy, and evaluate if test combination improves the liver-prognosis assessment in chronic hepatitis C (CHC). A total of 373 patients with compensated CHC, liver biopsy (Metavir F) and blood tests targeting fibrosis (APRI, FIB4, Fibrotest, Hepascore, FibroMeter) or cirrhosis (CirrhoMeter) were included. Significant liver-related events (SLRE) and liver-related deaths were recorded during follow-up (started the day of biopsy). During the median follow-up of 9.5 years (3508 person-years), 47 patients had a SLRE and 23 patients died from liver-related causes. For the prediction of first SLRE, most blood tests allowed higher prognostication than Metavir F [Harrell C-index: 0.811 (95% CI: 0.751-0.868)] with a significant increase for FIB4: 0.879 [0.832-0.919] (P = 0.002), FibroMeter: 0.870 [0.812-0.922] (P = 0.005) and APRI: 0.861 [0.813-0.902] (P = 0.039). Multivariate analysis identified FibroMeter, CirrhoMeter and sustained viral response as independent predictors of first SLRE. CirrhoMeter was the only independent predictor of liver-related death. The combination of FibroMeter and CirrhoMeter classifications into a new FM/CM classification improved the liver-prognosis assessment compared to Metavir F staging or single tests by identifying five subgroups of patients with significantly different prognoses. Some blood fibrosis tests are more accurate than liver biopsy for determining liver prognosis in CHC. A new combination of two complementary blood tests, one targeted for fibrosis and the other for cirrhosis, optimises assessment of liver-prognosis. © 2014 John Wiley & Sons Ltd.

  9. Dosimetric Advantages of Midventilation Compared With Internal Target Volume for Radiation Therapy of Pancreatic Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lens, Eelco, E-mail: e.lens@amc.uva.nl; Horst, Astrid van der; Versteijne, Eva

    2015-07-01

    Purpose: The midventilation (midV) approach can be used to take respiratory-induced pancreatic tumor motion into account during radiation therapy. In this study, the dosimetric consequences for organs at risk and tumor coverage of using a midV approach compared with using an internal target volume (ITV) were investigated. Methods and Materials: For each of the 18 patients, 2 treatment plans (25 × 2.0 Gy) were created, 1 using an ITV and 1 using a midV approach. The midV dose distribution was blurred using the respiratory-induced motion from 4-dimensional computed tomography. The resulting planning target volume (PTV) coverage for this blurred dosemore » distribution was analyzed; PTV coverage was required to be at least V{sub 95%} >98%. In addition, the change in PTV size and the changes in V{sub 10Gy}, V{sub 20Gy}, V{sub 30Gy}, V{sub 40Gy}, D{sub mean} and D{sub 2cc} for the stomach and for the duodenum were analyzed; differences were tested for significance using the Wilcoxon signed-rank test. Results: Using a midV approach resulted in sufficient target coverage. A highly significant PTV size reduction of 13.9% (P<.001) was observed. Also, all dose parameters for the stomach and duodenum, except the D{sub 2cc} of the duodenum, improved significantly (P≤.002). Conclusions: By using the midV approach to account for respiratory-induced tumor motion, a significant PTV reduction and significant dose reductions to the stomach and to the duodenum can be achieved when irradiating pancreatic tumors.« less

  10. Functional Brain Connectivity as a New Feature for P300 Speller.

    PubMed

    Kabbara, Aya; Khalil, Mohamad; El-Falou, Wassim; Eid, Hassan; Hassan, Mahmoud

    2016-01-01

    The brain is a large-scale complex network often referred to as the "connectome". Cognitive functions and information processing are mainly based on the interactions between distant brain regions. However, most of the 'feature extraction' methods used in the context of Brain Computer Interface (BCI) ignored the possible functional relationships between different signals recorded from distinct brain areas. In this paper, the functional connectivity quantified by the phase locking value (PLV) was introduced to characterize the evoked responses (ERPs) obtained in the case of target and non-targets visual stimuli. We also tested the possibility of using the functional connectivity in the context of 'P300 speller'. The proposed approach was compared to the well-known methods proposed in the state of the art of "P300 Speller", mainly the peak picking, the area, time/frequency based features, the xDAWN spatial filtering and the stepwise linear discriminant analysis (SWLDA). The electroencephalographic (EEG) signals recorded from ten subjects were analyzed offline. The results indicated that phase synchrony offers relevant information for the classification in a P300 speller. High synchronization between the brain regions was clearly observed during target trials, although no significant synchronization was detected for a non-target trial. The results showed also that phase synchrony provides higher performance than some existing methods for letter classification in a P300 speller principally when large number of trials is available. Finally, we tested the possible combination of both approaches (classical features and phase synchrony). Our findings showed an overall improvement of the performance of the P300-speller when using Peak picking, the area and frequency based features. Similar performances were obtained compared to xDAWN and SWLDA when using large number of trials.

  11. Designing divertor targets for uniform power load

    NASA Astrophysics Data System (ADS)

    Dekeyser, W.; Reiter, D.; Baelmans, M.

    2015-08-01

    Divertor design for next step fusion reactors heavily relies on 2D edge plasma modeling with codes as e.g. B2-EIRENE. While these codes are typically used in a design-by-analysis approach, in previous work we have shown that divertor design can alternatively be posed as a mathematical optimization problem, and solved very efficiently using adjoint methods adapted from computational aerodynamics. This approach has been applied successfully to divertor target shape design for more uniform power load. In this paper, the concept is further extended to include all contributions to the target power load, with particular focus on radiation. In a simplified test problem, we show the potential benefits of fully including the radiation load in the design cycle as compared to only assessing this load in a post-processing step.

  12. Development and evaluation of the British English coordinate response measure speech-in-noise test as an occupational hearing assessment tool.

    PubMed

    Semeraro, Hannah D; Rowan, Daniel; van Besouw, Rachel M; Allsopp, Adrian A

    2017-10-01

    The studies described in this article outline the design and development of a British English version of the coordinate response measure (CRM) speech-in-noise (SiN) test. Our interest in the CRM is as a SiN test with high face validity for occupational auditory fitness for duty (AFFD) assessment. Study 1 used the method of constant stimuli to measure and adjust the psychometric functions of each target word, producing a speech corpus with equal intelligibility. After ensuring all the target words had similar intelligibility, for Studies 2 and 3, the CRM was presented in an adaptive procedure in stationary speech-spectrum noise to measure speech reception thresholds and evaluate the test-retest reliability of the CRM SiN test. Studies 1 (n = 20) and 2 (n = 30) were completed by normal-hearing civilians. Study 3 (n = 22) was completed by hearing impaired military personnel. The results display good test-retest reliability (95% confidence interval (CI) < 2.1 dB) and concurrent validity when compared to the triple-digit test (r ≤ 0.65), and the CRM is sensitive to hearing impairment. The British English CRM using stationary speech-spectrum noise is a "ready to use" SiN test, suitable for investigation as an AFFD assessment tool for military personnel.

  13. Studies of the vestibulo-ocular reflex on STS 4, 5 and 6

    NASA Technical Reports Server (NTRS)

    Thornton, William E.; Pool, Sam L.; Moore, Thomas P.; Uri, John J.

    1988-01-01

    The vestibulo-ocular reflex (VOR) may be altered by weightlessness. Since this reflex plays a large role in visual stabilization, it was important to document any changes caused by space flight. This is a report on findings on STS-4 through 6 and is part of a larger study of neurosensory adaptation done on STS-4 through 8. Voluntary horizontal head oscillations at 1/3 Hz with amplitude of 30 deg right and left of center were recorded by a potentiometer and compared to eye position recorded by electroculography under the following conditions: eyes open, head fixed, tracking horizontal targets switched 0, 15, and 30 degrees right and left (optokinetic reflex - OKR - and calibration); eyes open and fixed on static external target with oscillation, (vestibulo ocular reflex, eyes closed - VOR EC); eyes open and wearing opaque goggles with target fixed in imagination (vestibulo-ocular reflex, eyes shaded - VOR ES); and eyes open and fixed on a head synchronized target with head oscillation (VOR suppression). No significant changes were found in voluntary head oscillation frequency or amplitude in those with (n=5), and without (n=3), space motion sickness (SMS), with phase of flight or test condition. Variations in head oscillation were too small to have produced detectable changes in test results.

  14. Computerized reminders for five preventive screening tests: generation of patient-specific letters incorporating physician preferences.

    PubMed Central

    Murphy, D. J.; Gross, R.; Buchanan, J.

    2000-01-01

    Compliance with preventive screening tests is inadequate in the United States. We describe a computer based system for generating reminder letters to patients who may have missed their indicated screening tests because they do not visit a provider regularly or missed their tests despite the fact that they do visit a provider. We started with national recommendations and generated a local consensus for test indications. We then used this set of indications and our electronic record to determine test deficiencies in our pilot pool of 3073 patients. The computer generated customized reminder letters targeting several tests. Physicians chose any patients who should not receive letters. The response rate for fecal occult blood (FOB) testing was 33% compared with an 18% historical compliance rate within the same community. FOB reminders generated improved test compliance. Test execution must be considered when commencing a program of screening test reminders. PMID:11079954

  15. Using habitat suitability models to target invasive plant species surveys.

    PubMed

    Crall, Alycia W; Jarnevich, Catherine S; Panke, Brendon; Young, Nick; Renz, Mark; Morisette, Jeffrey

    2013-01-01

    Managers need new tools for detecting the movement and spread of nonnative, invasive species. Habitat suitability models are a popular tool for mapping the potential distribution of current invaders, but the ability of these models to prioritize monitoring efforts has not been tested in the field. We tested the utility of an iterative sampling design (i.e., models based on field observations used to guide subsequent field data collection to improve the model), hypothesizing that model performance would increase when new data were gathered from targeted sampling using criteria based on the initial model results. We also tested the ability of habitat suitability models to predict the spread of invasive species, hypothesizing that models would accurately predict occurrences in the field, and that the use of targeted sampling would detect more species with less sampling effort than a nontargeted approach. We tested these hypotheses on two species at the state scale (Centaurea stoebe and Pastinaca sativa) in Wisconsin (USA), and one genus at the regional scale (Tamarix) in the western United States. These initial data were merged with environmental data at 30-m2 resolution for Wisconsin and 1-km2 resolution for the western United States to produce our first iteration models. We stratified these initial models to target field sampling and compared our models and success at detecting our species of interest to other surveys being conducted during the same field season (i.e., nontargeted sampling). Although more data did not always improve our models based on correct classification rate (CCR), sensitivity, specificity, kappa, or area under the curve (AUC), our models generated from targeted sampling data always performed better than models generated from nontargeted data. For Wisconsin species, the model described actual locations in the field fairly well (kappa = 0.51, 0.19, P < 0.01), and targeted sampling did detect more species than nontargeted sampling with less sampling effort (chi2 = 47.42, P < 0.01). From these findings, we conclude that habitat suitability models can be highly useful tools for guiding invasive species monitoring, and we support the use of an iterative sampling design for guiding such efforts.

  16. High-fat diet induced insulin resistance in pregnant rats through pancreatic pax6 signaling pathway.

    PubMed

    Wu, Hao; Liu, Yunyun; Wang, Hongkun; Xu, Xianming

    2015-01-01

    To explore the changes in pancreas islet function of pregnant rats after consumption of high-fat diet and the underlying mechanism. Thirty pregnant Wistar rats were randomly divided into two groups: high-fat diet group and normal control group. Twenty days after gestation, fasting blood glucose concentration (FBG) and fasting serum insulin concentration (FINS) were measured. Then, oral glucose tolerance test (OGTT) and insulin release test (IRT) were performed. Finally, all the rats were sacrificed and pancreas were harvested. Insulin sensitivity index (ISI) and insulin resistance index (HOMA-IR) were calculated according to FBG and FINS. RT-PCR and Real-time PCR were performed to study the expression of paired box 6 transcription factor (Pax6) and its target genes in pancreatic tissues. The body weight was significantly increased in the high-fat diet group compared with that of normal control rats (P<0.05). The fasting plasma glucose of rats in high-fat diet group was significantly increased compared with that of normal control rats (6.62 mmol/L vs. 4.96 mmol/L, P<0.05), however there was no significant difference in fasting serum insulin concentration between the two groups. OGTT and IRT were abnormal in the high-fat diet group. The high-fat diet rats were more prone to impaired glucose tolerance and insulin resistance. The level of the expression of Pax6 transcription factor and its target genes in pancreas, such as pancreatic and duodenal homeobox factor-1 (Pdx1), v-maf musculoaponeurotic fibrosarcoma oncogene homolog A (MafA) and glucose transporter 2 (Glut2) were decreased significantly compared with those of normal control group. High-fat diet feeding during pregnancy may induce insulin resistance in maternal rats by inhibiting pancreatic Pax6 and its target genes expression.

  17. Experimental investigation of a moving averaging algorithm for motion perpendicular to the leaf travel direction in dynamic MLC target tracking.

    PubMed

    Yoon, Jai-Woong; Sawant, Amit; Suh, Yelin; Cho, Byung-Chul; Suh, Tae-Suk; Keall, Paul

    2011-07-01

    In dynamic multileaf collimator (MLC) motion tracking with complex intensity-modulated radiation therapy (IMRT) fields, target motion perpendicular to the MLC leaf travel direction can cause beam holds, which increase beam delivery time by up to a factor of 4. As a means to balance delivery efficiency and accuracy, a moving average algorithm was incorporated into a dynamic MLC motion tracking system (i.e., moving average tracking) to account for target motion perpendicular to the MLC leaf travel direction. The experimental investigation of the moving average algorithm compared with real-time tracking and no compensation beam delivery is described. The properties of the moving average algorithm were measured and compared with those of real-time tracking (dynamic MLC motion tracking accounting for both target motion parallel and perpendicular to the leaf travel direction) and no compensation beam delivery. The algorithm was investigated using a synthetic motion trace with a baseline drift and four patient-measured 3D tumor motion traces representing regular and irregular motions with varying baseline drifts. Each motion trace was reproduced by a moving platform. The delivery efficiency, geometric accuracy, and dosimetric accuracy were evaluated for conformal, step-and-shoot IMRT, and dynamic sliding window IMRT treatment plans using the synthetic and patient motion traces. The dosimetric accuracy was quantified via a tgamma-test with a 3%/3 mm criterion. The delivery efficiency ranged from 89 to 100% for moving average tracking, 26%-100% for real-time tracking, and 100% (by definition) for no compensation. The root-mean-square geometric error ranged from 3.2 to 4.0 mm for moving average tracking, 0.7-1.1 mm for real-time tracking, and 3.7-7.2 mm for no compensation. The percentage of dosimetric points failing the gamma-test ranged from 4 to 30% for moving average tracking, 0%-23% for real-time tracking, and 10%-47% for no compensation. The delivery efficiency of moving average tracking was up to four times higher than that of real-time tracking and approached the efficiency of no compensation for all cases. The geometric accuracy and dosimetric accuracy of the moving average algorithm was between real-time tracking and no compensation, approximately half the percentage of dosimetric points failing the gamma-test compared with no compensation.

  18. Side effect profile similarities shared between antidepressants and immune-modulators reveal potential novel targets for treating major depressive disorders.

    PubMed

    Sun, Yu; Narayan, Vaibhav A; Wittenberg, Gayle M

    2016-10-21

    Side effects, or the adverse effects of drugs, contain important clinical phenotypic information that may be useful in predicting novel or unknown targets of a drug. It has been suggested that drugs with similar side-effect profiles may share common targets. The diagnostic class, Major Depressive Disorder, is increasingly viewed as being comprised of multiple depression subtypes with different biological root causes. One 'type' of depression generating substantial interest today focuses on patients with high levels of inflammatory burden, indicated by elevated levels of C-reactive proteins (CRP) and pro-inflammatory cytokines such as interleukin 6 (IL-6). It has been suggested that drugs targeting the immune system may have beneficial effect on this subtype of depressed patients, and several studies are underway to test this hypothesis directly. However, patients have been treated with both anti-inflammatory and antidepressant compounds for decades. It may be possible to exploit similarities in clinical readouts to better understand the antidepressant effects of immune-related drugs. Here we explore the space of approved drugs by comparing the drug side effect profiles of known antidepressants and drugs targeting the immune system, and further examine the findings by comparing the human cell line expression profiles induced by them with those induced by antidepressants. We found 7 immune-modulators and 14 anti-inflammatory drugs sharing significant side effect profile similarities with antidepressants. Five of the 7 immune modulators share most similar side effect profiles with antidepressants that modulate dopamine release and/or uptake. In addition, the immunosuppressant rapamycin and the glucocorticoid alclometasone induces transcriptional changes similar to multiple antidepressants. These findings suggest that some antidepressants and some immune-related drugs may affect common molecular pathways. Our findings support the idea that certain medications aimed at the immune system may be helpful in relieving depressive symptoms, and suggest that it may be of value to test immune-modulators for antidepressant-like activity in future proof-of-concept studies.

  19. Adaptation mechanisms, eccentricity profiles, and clinical implementation of red-on-white perimetry.

    PubMed

    Zele, Andrew J; Dang, Trung M; O'Loughlin, Rebecca K; Guymer, Robyn H; Harper, Alex; Vingrys, Algis J

    2008-05-01

    To determine the visual adaptation and retinal eccentricity profiles for red flickering and static test stimuli and report a clinical implementation of these stimuli in visual perimetry. The adaptation profile for red-on-white perimetry stimuli was measured using a threshold vs. intensity (TvI) paradigm at 0 degree and 12 degrees eccentricity and by comparing the eccentricity-related sensitivity change for red and white, static, and flickering targets in young normal trichromats (n = 5) and a group of dichromats (n = 5). A group of older normal control observers (n = 30) were tested and retinal disease was evaluated in persons having age-related maculopathy (n = 35) and diabetes (n = 12). Adaptation and eccentricity profiles indicate red static and flickering targets are detected by two mechanisms in the paramacular region, and a single mechanism for >5 degrees eccentricity. The group data for the older normal observers has a high level of inter-observer variability with a generalized reduction in sensitivity across the entire visual field. Group data for the participants with age-related maculopathy show reduced sensitivities that were pronounced in the central retina. The group data for the diabetic observers showed sensitivities that were reduced at all eccentricities. The disease-related sensitivity decline was more apparent with red than white stimuli. The adaptation profile and change in sensitivity with retinal eccentricity for the red-on-white perimetric stimuli are consistent with two detection processes. In the macula, the putative detection mechanism is color-opponent with static targets and non-opponent with flickering targets. At peripheral field locations, the putative detection mechanism is non-opponent for both static and flicker targets. The long-wavelength stimuli are less affected by the preretinal absorption common to aging. Red-on-white static and flicker perimetry may be useful for monitoring retinal disease, revealing greater abnormalities compared with conventional white-on-white perimetry, especially in the macula where two detection mechanisms are found.

  20. Effect of home testing of international normalized ratio on clinical events.

    PubMed

    Matchar, David B; Jacobson, Alan; Dolor, Rowena; Edson, Robert; Uyeda, Lauren; Phibbs, Ciaran S; Vertrees, Julia E; Shih, Mei-Chiung; Holodniy, Mark; Lavori, Philip

    2010-10-21

    Warfarin anticoagulation reduces thromboembolic complications in patients with atrial fibrillation or mechanical heart valves, but effective management is complex, and the international normalized ratio (INR) is often outside the target range. As compared with venous plasma testing, point-of-care INR measuring devices allow greater testing frequency and patient involvement and may improve clinical outcomes. We randomly assigned 2922 patients who were taking warfarin because of mechanical heart valves or atrial fibrillation and who were competent in the use of point-of-care INR devices to either weekly self-testing at home or monthly high-quality testing in a clinic. The primary end point was the time to a first major event (stroke, major bleeding episode, or death). The patients were followed for 2.0 to 4.75 years, for a total of 8730 patient-years of follow-up. The time to the first primary event was not significantly longer in the self-testing group than in the clinic-testing group (hazard ratio, 0.88; 95% confidence interval, 0.75 to 1.04; P=0.14). The two groups had similar rates of clinical outcomes except that the self-testing group reported more minor bleeding episodes. Over the entire follow-up period, the self-testing group had a small but significant improvement in the percentage of time during which the INR was within the target range (absolute difference between groups, 3.8 percentage points; P<0.001). At 2 years of follow-up, the self-testing group also had a small but significant improvement in patient satisfaction with anticoagulation therapy (P=0.002) and quality of life (P<0.001). As compared with monthly high-quality clinic testing, weekly self-testing did not delay the time to a first stroke, major bleeding episode, or death to the extent suggested by prior studies. These results do not support the superiority of self-testing over clinic testing in reducing the risk of stroke, major bleeding episode, and death among patients taking warfarin therapy. (Funded by the Department of Veterans Affairs Cooperative Studies Program; ClinicalTrials.gov number, NCT00032591.).

  1. Detection performance in clutter with variable resolution

    NASA Astrophysics Data System (ADS)

    Schmieder, D. E.; Weathersby, M. R.

    1983-07-01

    Experiments were conducted to determine the influence of background clutter on target detection criteria. The experiment consisted of placing observers in front of displayed images on a TV monitor. Observer ability to detect military targets embedded in simulated natural and manmade background clutter was measured when there was unlimited viewing time. Results were described in terms of detection probability versus target resolution for various signal to clutter ratios (SCR). The experiments were preceded by a search for a meaningful clutter definition. The selected definition was a statistical measure computed by averaging the standard deviation of contiguous scene cells over the whole scene. The cell size was comparable to the target size. Observer test results confirmed the expectation that the resolution required for a given detection probability was a continuum function of the clutter level. At the lower SCRs the resolution required for a high probability of detection was near 6 line pairs per target (LP/TGT), while at the higher SCRs it was found that a resoluton of less than 0.25 LP/TGT would yield a high probability of detection. These results are expected to aid in target acquisition performance modeling and to lead to improved specifications for imaging automatic target screeners.

  2. Positional priming of visual pop-out search is supported by multiple spatial reference frames

    PubMed Central

    Gokce, Ahu; Müller, Hermann J.; Geyer, Thomas

    2015-01-01

    The present study investigates the representations(s) underlying positional priming of visual ‘pop-out’ search (Maljkovic and Nakayama, 1996). Three search items (one target and two distractors) were presented at different locations, in invariant (Experiment 1) or random (Experiment 2) cross-trial sequences. By these manipulations it was possible to disentangle retinotopic, spatiotopic, and object-centered priming representations. Two forms of priming were tested: target location facilitation (i.e., faster reaction times – RTs– when the trial n target is presented at a trial n-1 target relative to n-1 blank location) and distractor location inhibition (i.e., slower RTs for n targets presented at n-1 distractor compared to n-1 blank locations). It was found that target locations were coded in positional short-term memory with reference to both spatiotopic and object-centered representations (Experiment 1 vs. 2). In contrast, distractor locations were maintained in an object-centered reference frame (Experiments 1 and 2). We put forward the idea that the uncertainty induced by the experiment manipulation (predictable versus random cross-trial item displacements) modulates the transition from object- to space-based representations in cross-trial memory for target positions. PMID:26136718

  3. Helical tomotherapy for radiotherapy in esophageal cancer: a preferred plan with better conformal target coverage and more homogeneous dose distribution.

    PubMed

    Chen, Yi-Jen; Liu, An; Han, Chunhui; Tsai, Peter T; Schultheiss, Timothy E; Pezner, Richard D; Vora, Nilesh; Lim, Dean; Shibata, Stephen; Kernstine, Kemp H; Wong, Jeffrey Y C

    2007-01-01

    We compare different radiotherapy techniques-helical tomotherapy (tomotherapy), step-and-shoot IMRT (IMRT), and 3-dimensional conformal radiotherapy (3DCRT)-for patients with mid-distal esophageal carcinoma on the basis of dosimetric analysis. Six patients with locally advanced mid-distal esophageal carcinoma were treated with neoadjuvant chemoradiation followed by surgery. Radiotherapy included 50 Gy to gross planning target volume (PTV) and 45 Gy to elective PTV in 25 fractions. Tomotherapy, IMRT, and 3DCRT plans were generated. Dose-volume histograms (DVHs), homogeneity index (HI), volumes of lung receiving more than 10, 15, or 20 Gy (V(10), V(15), V(20)), and volumes of heart receiving more than 30 or 45 Gy (V(30), V(45)) were determined. Statistical analysis was performed by paired t-tests. By isodose distributions and DVHs, tomotherapy plans showed sharper dose gradients, more conformal coverage, and better HI for both gross and elective PTVs compared with IMRT or 3DCRT plans. Mean V(20) of lung was significantly reduced in tomotherapy plans. However, tomotherapy and IMRT plans resulted in larger V(10) of lung compared to 3DCRT plans. The heart was significantly spared in tomotherapy and IMRT plans compared to 3DCRT plans in terms of V(30) and V(45). We conclude that tomotherapy plans are superior in terms of target conformity, dose homogeneity, and V(20) of lung.

  4. Clinical acceptance testing and scanner comparison of ultrasound shear wave elastography.

    PubMed

    Long, Zaiyang; Tradup, Donald J; Song, Pengfei; Stekel, Scott F; Chen, Shigao; Glazebrook, Katrina N; Hangiandreou, Nicholas J

    2018-03-15

    Because of the rapidly growing use of ultrasound shear wave elastography (SWE) in clinical practices, there is a significant need for development of clinical physics performance assessment methods for this technology. This study aims to report two clinical medical physicists' tasks: (a) acceptance testing (AT) of SWE function on ten commercial ultrasound systems for clinical liver application and (b) comparison of SWE measurements of targets across vendors for clinical musculoskeletal application. For AT, ten GE LOGIQ E9 XDclear 2.0 scanners with ten C1-6-D and ten 9L-D transducers were studied using two commercial homogenous phantoms. Five measurements were acquired at two depths for each scanner/transducer pair by two operators. Additional tests were performed to access effects of different coupling media, phantom locations and operators. System deviations were less than 5% of group mean or three times standard deviation; therefore, all systems passed AT. A test protocol was provided based on results that no statistically significant difference was observed between using ultrasound gel and salt water for coupling, among different phantom locations, and that interoperator and intraoperator coefficient of variation was less than 3%. For SWE target measurements, two systems were compared - a Supersonic Aixplorer scanner with a SL10-2 and a SL15-4 transducer, and an abovementioned GE scanner with 9L-D transducer. Two stepped cylinders with diameters of 4.05-10.40 mm were measured both longitudinally and transaxially. Target shear wave speed quantification was performed using an in-house MATLAB program. Using the target shear wave speed deduced from phantom specs as a reference, SL15-4 performed the best at the measured depth. However, it was challenging to reliably measure a 4.05 mm target for either system. The reported test methods and results could provide important information when dealing with SWE-related tasks in the clinical environment. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  5. A real-time comparison between direct control, sequential pattern recognition control and simultaneous pattern recognition control using a Fitts’ law style assessment procedure

    PubMed Central

    2014-01-01

    Background Pattern recognition (PR) based strategies for the control of myoelectric upper limb prostheses are generally evaluated through offline classification accuracy, which is an admittedly useful metric, but insufficient to discuss functional performance in real time. Existing functional tests are extensive to set up and most fail to provide a challenging, objective framework to assess the strategy performance in real time. Methods Nine able-bodied and two amputee subjects gave informed consent and participated in the local Institutional Review Board approved study. We designed a two-dimensional target acquisition task, based on the principles of Fitts’ law for human motor control. Subjects were prompted to steer a cursor from the screen center of into a series of subsequently appearing targets of different difficulties. Three cursor control systems were tested, corresponding to three electromyography-based prosthetic control strategies: 1) amplitude-based direct control (the clinical standard of care), 2) sequential PR control, and 3) simultaneous PR control, allowing for a concurrent activation of two degrees of freedom (DOF). We computed throughput (bits/second), path efficiency (%), reaction time (second), and overshoot (%)) and used general linear models to assess significant differences between the strategies for each metric. Results We validated the proposed methodology by achieving very high coefficients of determination for Fitts’ law. Both PR strategies significantly outperformed direct control in two-DOF targets and were more intuitive to operate. In one-DOF targets, the simultaneous approach was the least precise. The direct control was efficient in one-DOF targets but cumbersome to operate in two-DOF targets through a switch-depended sequential cursor control. Conclusions We designed a test, capable of comprehensively describing prosthetic control strategies in real time. When implemented on control subjects, the test was able to capture statistically significant differences (p < 0.05) in control strategies when considering throughputs, path efficiencies and reaction times. Of particular note, we found statistically significant (p < 0.01) improvements in throughputs and path efficiencies with simultaneous PR when compared to direct control or sequential PR. Amputees could readily achieve the task; however a limited number of subjects was tested and a statistical analysis was not performed with that population. PMID:24886664

  6. A real-time comparison between direct control, sequential pattern recognition control and simultaneous pattern recognition control using a Fitts' law style assessment procedure.

    PubMed

    Wurth, Sophie M; Hargrove, Levi J

    2014-05-30

    Pattern recognition (PR) based strategies for the control of myoelectric upper limb prostheses are generally evaluated through offline classification accuracy, which is an admittedly useful metric, but insufficient to discuss functional performance in real time. Existing functional tests are extensive to set up and most fail to provide a challenging, objective framework to assess the strategy performance in real time. Nine able-bodied and two amputee subjects gave informed consent and participated in the local Institutional Review Board approved study. We designed a two-dimensional target acquisition task, based on the principles of Fitts' law for human motor control. Subjects were prompted to steer a cursor from the screen center of into a series of subsequently appearing targets of different difficulties. Three cursor control systems were tested, corresponding to three electromyography-based prosthetic control strategies: 1) amplitude-based direct control (the clinical standard of care), 2) sequential PR control, and 3) simultaneous PR control, allowing for a concurrent activation of two degrees of freedom (DOF). We computed throughput (bits/second), path efficiency (%), reaction time (second), and overshoot (%)) and used general linear models to assess significant differences between the strategies for each metric. We validated the proposed methodology by achieving very high coefficients of determination for Fitts' law. Both PR strategies significantly outperformed direct control in two-DOF targets and were more intuitive to operate. In one-DOF targets, the simultaneous approach was the least precise. The direct control was efficient in one-DOF targets but cumbersome to operate in two-DOF targets through a switch-depended sequential cursor control. We designed a test, capable of comprehensively describing prosthetic control strategies in real time. When implemented on control subjects, the test was able to capture statistically significant differences (p < 0.05) in control strategies when considering throughputs, path efficiencies and reaction times. Of particular note, we found statistically significant (p < 0.01) improvements in throughputs and path efficiencies with simultaneous PR when compared to direct control or sequential PR. Amputees could readily achieve the task; however a limited number of subjects was tested and a statistical analysis was not performed with that population.

  7. Update On The Development, Testing, And Manufacture Of High Density LEU-Foil Targets For The Production Of Mo-99

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Creasy, John T

    2015-05-12

    This project has the objective to reduce and/or eliminate the use of HEU in commerce. Steps in the process include developing a target testing methodology that is bounding for all Mo-99 target irradiators, establishing a maximum target LEU-foil mass, developing a LEU-foil target qualification document, developing a bounding target failure analysis methodology (failure in reactor containment), optimizing safety vs. economics (goal is to manufacture a safe, but relatively inexpensive target to offset the inherent economic disadvantage of using LEU in place of HEU), and developing target material specifications and manufacturing QC test criteria. The slide presentation is organized under themore » following topics: Objective, Process Overview, Background, Team Structure, Key Achievements, Experiment and Activity Descriptions, and Conclusions. The High Density Target project has demonstrated: approx. 50 targets irradiated through domestic and international partners; proof of concept for two front end processing methods; fabrication of uranium foils for target manufacture; quality control procedures and steps for manufacture; multiple target assembly techniques; multiple target disassembly devices; welding of targets; thermal, hydraulic, and mechanical modeling; robust target assembly parametric studies; and target qualification analysis for insertion into very high flux environment. The High Density Target project has tested and proven several technologies that will benefit current and future Mo-99 producers.« less

  8. Shielding analyses for repetitive high energy pulsed power accelerators

    NASA Astrophysics Data System (ADS)

    Jow, H. N.; Rao, D. V.

    Sandia National Laboratories (SNL) designs, tests and operates a variety of accelerators that generate large amounts of high energy Bremsstrahlung radiation over an extended time. Typically, groups of similar accelerators are housed in a large building that is inaccessible to the general public. To facilitate independent operation of each accelerator, test cells are constructed around each accelerator to shield it from the radiation workers occupying surrounding test cells and work-areas. These test cells, about 9 ft. high, are constructed of high density concrete block walls that provide direct radiation shielding. Above the target areas (radiation sources), lead or steel plates are used to minimize skyshine radiation. Space, accessibility and cost considerations impose certain restrictions on the design of these test cells. SNL Health Physics division is tasked to evaluate the adequacy of each test cell design and compare resultant dose rates with the design criteria stated in DOE Order 5480.11. In response, SNL Health Physics has undertaken an intensive effort to assess existing radiation shielding codes and compare their predictions against measured dose rates. This paper provides a summary of the effort and its results.

  9. Can Handheld Thermal Imaging Technology Improve Detection of Poachers in African Bushveldt?

    PubMed Central

    Dandy, Shantelle; Stubbs, Hannah; MacTavish, Dougal; MacTavish, Lynne

    2015-01-01

    Illegal hunting (poaching) is a global threat to wildlife. Anti-poaching initiatives are making increasing use of technology, such as infrared thermography (IRT), to support traditional foot and vehicle patrols. To date, the effectiveness of IRT for poacher location has not been tested under field conditions, where thermal signatures are often complex. Here, we test the hypothesis that IRT will increase the distance over which a poacher hiding in African scrub bushveldt can be detected relative to a conventional flashlight. We also test whether any increase in effectiveness is related to the cost and complexity of the equipment by comparing comparatively expensive (22000 USD) and relatively inexpensive (2000 USD) IRT devices. To test these hypotheses we employ a controlled, fully randomised, double-blind procedure to find a poacher in nocturnal field conditions in African bushveldt. Each of our 27 volunteer observers walked three times along a pathway using one detection technology on each pass in randomised order. They searched a prescribed search area of bushveldt within which the target was hiding. Hiding locations were pre-determined, randomised, and changed with each pass. Distances of first detection and positive detection were noted. All technologies could be used to detect the target. Average first detection distance for flashlight was 37.3m, improving by 19.8m to 57.1m using LIRT and by a further 11.2m to 68.3m using HIRT. Although detection distances were significantly greater for both IRTs compared to flashlight, there was no significant difference between LIRT and HIRT. False detection rates were low and there was no significant association between technology and accuracy of detection. Although IRT technology should ideally be tested in the specific environment intended before significant investment is made, we conclude that IRT technology is promising for anti-poaching patrols and that for this purpose low cost IRT units are as effective as units ten times more expensive. PMID:26110865

  10. Rapid enteric testing to permit targeted antimicrobial therapy, with and without Lactobacillus reuteri probiotics, for paediatric acute diarrhoeal disease in Botswana: A pilot, randomized, factorial, controlled trial.

    PubMed

    Pernica, Jeffrey M; Steenhoff, Andrew P; Mokomane, Margaret; Moorad, Banno; Lechiile, Kwana; Smieja, Marek; Mazhani, Loeto; Cheng, Ji; Kelly, Matthew S; Loeb, Mark; Stordal, Ketil; Goldfarb, David M

    2017-01-01

    Diarrhoeal disease is the second-leading cause of death in young children. Current guidelines recommend treating children with acute non-bloody diarrhea with oral rehydration solutions and zinc, but not antimicrobials. However, in many resource-limited settings, infections with treatable enteric bacterial and protozoan pathogens are common. Probiotics have shown promise as an adjunct treatment for diarrhoea but have not been studied in sub-Saharan Africa. We conducted a pilot, factorial, randomized, placebo-controlled trial of children aged 2-60 months hospitalized in Botswana for acute non-bloody diarrhoea. A rapid test-and-treat intervention, consisting of multiplex PCR testing of rectal swabs taken at enrolment, accompanied by targeted antimicrobial therapy if treatable pathogens were detected, was compared to the reference standard of no stool testing. Additionally, Lactobacillus reuteri DSM 17938 x 60 days was compared to placebo treatment. The main objective of this pilot study was to assess feasibility. The primary clinical outcome was the increase in age-standardized height (HAZ) at 60 days adjusted for baseline HAZ. Seventy-six patients were enrolled over a seven-month study period. We judged that the recruitment rate, lab processing times, communication protocols, provision of specific antimicrobials, and follow-up rates were acceptable. Compared to the reference arm (no stool testing and placebo treatment), the combination of the rapid test-and-treat strategy plus L. reuteri DSM 17938 was associated with an increase of 0.61 HAZ (95% CI 0.09-1.13) and 93% lower odds of recurrent diarrhoea (OR 0.07, 95%CI 0.01-0.61) at 60 days. We demonstrated that it was feasible to evaluate the study interventions in Botswana. Despite the small sample size, we observed a statistically significant increase in HAZ at 60 days and significantly lower odds of recurrent diarrhoea in children receiving both rapid test-and-treat and L. reuteri. There is sufficient evidence to warrant proceeding with a larger follow-up trial in a similar setting.

  11. The Statistical Analysis Techniques to Support the NGNP Fuel Performance Experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bihn T. Pham; Jeffrey J. Einerson

    2010-06-01

    This paper describes the development and application of statistical analysis techniques to support the AGR experimental program on NGNP fuel performance. The experiments conducted in the Idaho National Laboratory’s Advanced Test Reactor employ fuel compacts placed in a graphite cylinder shrouded by a steel capsule. The tests are instrumented with thermocouples embedded in graphite blocks and the target quantity (fuel/graphite temperature) is regulated by the He-Ne gas mixture that fills the gap volume. Three techniques for statistical analysis, namely control charting, correlation analysis, and regression analysis, are implemented in the SAS-based NGNP Data Management and Analysis System (NDMAS) for automatedmore » processing and qualification of the AGR measured data. The NDMAS also stores daily neutronic (power) and thermal (heat transfer) code simulation results along with the measurement data, allowing for their combined use and comparative scrutiny. The ultimate objective of this work includes (a) a multi-faceted system for data monitoring and data accuracy testing, (b) identification of possible modes of diagnostics deterioration and changes in experimental conditions, (c) qualification of data for use in code validation, and (d) identification and use of data trends to support effective control of test conditions with respect to the test target. Analysis results and examples given in the paper show the three statistical analysis techniques providing a complementary capability to warn of thermocouple failures. It also suggests that the regression analysis models relating calculated fuel temperatures and thermocouple readings can enable online regulation of experimental parameters (i.e. gas mixture content), to effectively maintain the target quantity (fuel temperature) within a given range.« less

  12. Exploratory Study of 4D Versus 3D Robust Optimization in Intensity-Modulated Proton Therapy for Lung Cancer

    PubMed Central

    Liu, Wei; Schild, Steven E.; Chang, Joe Y.; Liao, Zhongxing; Chang, Yu-Hui; Wen, Zhifei; Shen, Jiajian; Stoker, Joshua B.; Ding, Xiaoning; Hu, Yanle; Sahoo, Narayan; Herman, Michael G.; Vargas, Carlos; Keole, Sameer; Wong, William; Bues, Martin

    2015-01-01

    Background To compare the impact of uncertainties and interplay effect on 3D and 4D robustly optimized intensity-modulated proton therapy (IMPT) plans for lung cancer in an exploratory methodology study. Methods IMPT plans were created for 11 non-randomly selected non-small-cell lung cancer (NSCLC) cases: 3D robustly optimized plans on average CTs with internal gross tumor volume density overridden to irradiate internal target volume, and 4D robustly optimized plans on 4D CTs to irradiate clinical target volume (CTV). Regular fractionation (66 Gy[RBE] in 33 fractions) were considered. In 4D optimization, the CTV of individual phases received non-uniform doses to achieve a uniform cumulative dose. The root-mean-square-dose volume histograms (RVH) measured the sensitivity of the dose to uncertainties, and the areas under the RVH curve (AUCs) were used to evaluate plan robustness. Dose evaluation software modeled time-dependent spot delivery to incorporate interplay effect with randomized starting phases of each field per fraction. Dose-volume histogram indices comparing CTV coverage, homogeneity, and normal tissue sparing were evaluated using Wilcoxon signed-rank test. Results 4D robust optimization plans led to smaller AUC for CTV (14.26 vs. 18.61 (p=0.001), better CTV coverage (Gy[RBE]) [D95% CTV: 60.6 vs 55.2 (p=0.001)], and better CTV homogeneity [D5%–D95% CTV: 10.3 vs 17.7 (p=0.002)] in the face of uncertainties. With interplay effect considered, 4D robust optimization produced plans with better target coverage [D95% CTV: 64.5 vs 63.8 (p=0.0068)], comparable target homogeneity, and comparable normal tissue protection. The benefits from 4D robust optimization were most obvious for the 2 typical stage III lung cancer patients. Conclusions Our exploratory methodology study showed that, compared to 3D robust optimization, 4D robust optimization produced significantly more robust and interplay-effect-resistant plans for targets with comparable dose distributions for normal tissues. A further study with a larger and more realistic patient population is warranted to generalize the conclusions. PMID:26725727

  13. Hypoxia-Targeting Drug Evofosfamide (TH-302) Enhances Sunitinib Activity in Neuroblastoma Xenograft Models.

    PubMed

    Kumar, Sushil; Sun, Jessica D; Zhang, Libo; Mokhtari, Reza Bayat; Wu, Bing; Meng, Fanying; Liu, Qian; Bhupathi, Deepthi; Wang, Yan; Yeger, Herman; Hart, Charles; Baruchel, Sylvain

    2018-05-23

    Antiangiogenic therapy has shown promising results in preclinical and clinical trials. However, tumor cells acquire resistance to this therapy by gaining ability to survive and proliferate under hypoxia induced by antiangiogenic therapy. Combining antiangiogenic therapy with hypoxia-activated prodrugs can overcome this limitation. Here, we have tested the combination of antiangiogenic drug sunitinib in combination with hypoxia-activated prodrug evofosfamide in neuroblastoma. In vitro, neuroblastoma cell line SK-N-BE(2) was 40-folds sensitive to evofosfamide under hypoxia compared to normoxia. In IV metastatic model, evofosfamide significantly increased mice survival compared to the vehicle (P=.02). In SK-N-BE(2) subcutaneous xenograft model, we tested two different treatment regimens using 30 mg/kg sunitinib and 50 mg/kg evofosfamide. Here, sunitinib therapy when started along with evofosfamide treatment showed higher efficacy compared to single agents in subcutaneous SK-N-BE(2) xenograft model, whereas sunitinib when started 7 days after evofosfamide treatment did not have any advantage compared to treatment with either single agent. Immunofluorescence of tumor sections revealed higher number of apoptotic cells and hypoxic areas compared to either single agent when both treatments were started together. Treatment with 80 mg/kg sunitinib with 50 mg/kg evofosfamide was significantly superior to single agents in both xenograft and metastatic models. This study confirms the preclinical efficacy of sunitinib and evofosfamide in murine models of aggressive neuroblastoma. Sunitinib enhances the efficacy of evofosfamide by increasing hypoxic areas, and evofosfamide targets hypoxic tumor cells. Consequently, each drug enhances the activity of the other. Copyright © 2018. Published by Elsevier Inc.

  14. False Positivity of Non-Targeted Infections in Malaria Rapid Diagnostic Tests: The Case of Human African Trypanosomiasis

    PubMed Central

    Gillet, Philippe; Mumba Ngoyi, Dieudonné; Lukuka, Albert; Kande, Viktor; Atua, Benjamin; van Griensven, Johan; Muyembe, Jean-Jacques; Jacobs, Jan; Lejon, Veerle

    2013-01-01

    Background In endemic settings, diagnosis of malaria increasingly relies on the use of rapid diagnostic tests (RDTs). False positivity of such RDTs is poorly documented, although it is especially relevant in those infections that resemble malaria, such as human African trypanosomiasis (HAT). We therefore examined specificity of malaria RDT products among patients infected with Trypanosoma brucei gambiense. Methodology/Principal Findings Blood samples of 117 HAT patients and 117 matched non-HAT controls were prospectively collected in the Democratic Republic of the Congo. Reference malaria diagnosis was based on real-time PCR. Ten commonly used malaria RDT products were assessed including three two-band and seven three-band products, targeting HRP-2, Pf-pLDH and/or pan-pLDH antigens. Rheumatoid factor was determined in PCR negative subjects. Specificity of the 10 malaria RDT products varied between 79.5 and 100% in HAT-negative controls and between 11.3 and 98.8% in HAT patients. For seven RDT products, specificity was significantly lower in HAT patients compared to controls. False positive reactions in HAT were mainly observed for pan-pLDH test lines (specificities between 13.8 and 97.5%), but also occurred frequently for the HRP-2 test line (specificities between 67.9 and 98.8%). The Pf-pLDH test line was not affected by false-positive lines in HAT patients (specificities between 97.5 and 100%). False positivity was not associated to rheumatoid factor, detected in 7.6% of controls and 1.2% of HAT patients. Conclusions/Significance Specificity of some malaria RDT products in HAT was surprisingly low, and constitutes a risk for misdiagnosis of a fatal but treatable infection. Our results show the importance to assess RDT specificity in non-targeted infections when evaluating diagnostic tests. PMID:23638201

  15. Diagrams increase the recall of nondepicted text when understanding is also increased.

    PubMed

    Serra, Michael J

    2010-02-01

    Multimedia presentations typically produce better memory and understanding than do single-medium presentations. Little research, however, has considered the effect of multimedia on memory for nonmultimedia information within a large multimedia presentation (e.g., nondepicted text in a large text with diagrams). To this end, the present two experiments compared memory for target text information that was either depicted in diagrams or not. Participants (n = 180) studied either a text-only version of a text about lightning or a text-with-diagrams version in which half the target information was depicted in diagrams. Memory was tested with both free recall and cued recall questions. Overall, diagrams did not affect memory for the entire text; diagrams increased memory only for the information they depicted. Diagrams exerted a generalized effect on free recall only when diagrams increased the overall understanding of the text (i.e., when the participants studied the materials twice before the test).

  16. Repetition blindness and homophone blindness in young and older adults.

    PubMed

    Tyrrell, Caitlin J; James, Lori E; Noble, Paula M

    2016-11-01

    We tested age effects on repetition blindness (RB), defined as the reduced probability of reporting a target word following presentation of the same word in a rapidly presented list. We also tested age effects on homophone blindness (HB), in which the first word is a homophone of the target word rather than a repeated word. Thirty young and 28 older adults viewed rapidly presented lists of words containing repeated, homophone, or unrepeated word pairs and reported all of the words immediately after each list. Older adults exhibited a greater degree of RB and HB than young adults using a conditional scoring method that provides certainty that blindness has occurred. The existence of RB and HB for both age groups, and increased blindness for older compared to young adults, supports predictions of a binding theory that has successfully accounted for a wide range of phenomena in cognitive aging.

  17. Remote detection of rotating machinery with a portable atomic magnetometer.

    PubMed

    Marmugi, Luca; Gori, Lorenzo; Hussain, Sarah; Deans, Cameron; Renzoni, Ferruccio

    2017-01-20

    We demonstrate remote detection of rotating machinery, using an atomic magnetometer at room temperature and in an unshielded environment. The system relies on the coupling of the AC magnetic signature of the target with the spin-polarized, precessing atomic vapor of a radio-frequency optical atomic magnetometer. The AC magnetic signatures of rotating equipment or electric motors appear as sidebands in the power spectrum of the atomic sensor, which can be tuned to avoid noisy bands that would otherwise hamper detection. A portable apparatus is implemented and experimentally tested. Proof-of-concept investigations are performed with test targets mimicking possible applications, and the operational conditions for optimum detection are determined. Our instrument provides comparable or better performance than a commercial fluxgate and allows detection of rotating machinery behind a wall. These results demonstrate the potential for ultrasensitive devices for remote industrial and usage monitoring, security, and surveillance.

  18. Enhanced startle responsivity 24 hours after acute stress exposure.

    PubMed

    Herten, Nadja; Otto, Tobias; Adolph, Dirk; Pause, Bettina M; Kumsta, Robert; Wolf, Oliver T

    2016-10-01

    Cortisol release in a stressful situation can be beneficial for memory encoding and memory consolidation. Stimuli, such as odors, related to the stressful episode may successfully cue memory contents of the stress experience. The current investigation aimed at testing the potency of stress to influence startle responsivity 24 hr later and to implicitly reactivate emotional memory traces triggered by an odor involved. Participants were assigned to either a stress (Trier Social Stress Test [TSST]) or control (friendly TSST [f-TSST]) condition featuring an ambient odor. On the next day, participants underwent an auditory startle paradigm while their eyeblink reflex was recorded by an electrooculogram. Three different olfactory stimuli were delivered, one being the target odor presented the day before. Additionally, negative, positive, and pictures of the committee members were included for comparing general startle responsivity and fear-potentiated startle. Participants of the stress group demonstrated an enhanced startle response across all stimuli compared to participants of the control group. There were no specific effects with regard to the target odor. The typical fear-potentiated startle response occurred. Stressed participants tended to rate the target odor more aversive than control participants. Odor recognition memory did not differ between the groups, suggesting an implicit effect on odor valence. Our results show that acute stress exposure enhances startle responsivity 24 hr later. This effect might be caused by a shift of amygdala function causing heightened sensitivity, but lower levels of specificity. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  19. A computer vision-based approach for structural displacement measurement

    NASA Astrophysics Data System (ADS)

    Ji, Yunfeng

    2010-04-01

    Along with the incessant advancement in optics, electronics and computer technologies during the last three decades, commercial digital video cameras have experienced a remarkable evolution, and can now be employed to measure complex motions of objects with sufficient accuracy, which render great assistance to structural displacement measurement in civil engineering. This paper proposes a computer vision-based approach for dynamic measurement of structures. One digital camera is used to capture image sequences of planar targets mounted on vibrating structures. The mathematical relationship between image plane and real space is established based on computer vision theory. Then, the structural dynamic displacement at the target locations can be quantified using point reconstruction rules. Compared with other tradition displacement measurement methods using sensors, such as accelerometers, linear-variable-differential-transducers (LVDTs) and global position system (GPS), the proposed approach gives the main advantages of great flexibility, a non-contact working mode and ease of increasing measurement points. To validate, four tests of sinusoidal motion of a point, free vibration of a cantilever beam, wind tunnel test of a cross-section bridge model, and field test of bridge displacement measurement, are performed. Results show that the proposed approach can attain excellent accuracy compared with the analytical ones or the measurements using conventional transducers, and proves to deliver an innovative and low cost solution to structural displacement measurement.

  20. Visual impairment in Finnish Usher syndrome type III.

    PubMed

    Plantinga, Rutger F; Pennings, Ronald J E; Huygen, Patrick L M; Sankila, Eeva-Marja; Tuppurainen, Kaija; Kleemola, Leenamaija; Cremers, Cor W R J; Deutman, August F

    2006-02-01

    To evaluate visual impairment in Finnish Usher syndrome type 3 (USH3) and compare this with visual impairment in Usher syndrome types 1b (USH1b) and 2a (USH2a). We carried out a retrospective study of 28 Finnish USH3 patients, 24 Dutch USH2a patients and 17 Dutch USH1b patients. Cross-sectional regression analyses of the functional acuity score (FAS), functional field score (FFS*) and functional vision score (FVS*) related to age were performed for all patients. The FFS* and FVS* were calculated using the isoptre V-4 test target instead of the usual III-4 target. Statistical tests relating to regression lines and Student's t-test were used to compare between USH3 patients and the other genetic subtypes of Usher syndrome. Cross-sectional analyses revealed significant deterioration in the FAS (1.3% per year), FFS* (1.4% per year) and FVS* (1.8% per year) with advancing age in the USH3 patient group. At a given age the USH3 patients showed significantly poorer visual field function than the USH2a patients. The rate of deterioration in visual function in Finnish USH3 patients was fairly similar to that in Dutch USH1b or USH2a patients. At a given age, visual field impairment in USH3 patients was similar to that in USH1b patients but poorer than in USH2a patients.

  1. Open angle glaucoma effects on preattentive visual search efficiency for flicker, motion displacement and orientation pop-out tasks.

    PubMed

    Loughman, James; Davison, Peter; Flitcroft, Ian

    2007-11-01

    Preattentive visual search (PAVS) describes rapid and efficient retinal and neural processing capable of immediate target detection in the visual field. Damage to the nerve fibre layer or visual pathway might reduce the efficiency with which the visual system performs such analysis. The purpose of this study was to test the hypothesis that patients with glaucoma are impaired on parallel search tasks, and that this would serve to distinguish glaucoma in early cases. Three groups of observers (glaucoma patients, suspect and normal individuals) were examined, using computer-generated flicker, orientation, and vertical motion displacement targets to assess PAVS efficiency. The task required rapid and accurate localisation of a singularity embedded in a field of 119 homogeneous distractors on either the left or right-hand side of a computer monitor. All subjects also completed a choice reaction time (CRT) task. Independent sample T tests revealed PAVS efficiency to be significantly impaired in the glaucoma group compared with both normal and suspect individuals. Performance was impaired in all types of glaucoma tested. Analysis between normal and suspect individuals revealed a significant difference only for motion displacement response times. Similar analysis using a PAVS/CRT index confirmed the glaucoma findings but also showed statistically significant differences between suspect and normal individuals across all target types. A test of PAVS efficiency appears capable of differentiating early glaucoma from both normal and suspect cases. Analysis incorporating a PAVS/CRT index enhances the diagnostic capacity to differentiate normal from suspect cases.

  2. A comparison of sperm agglutination and immobilization assays with a quantitative ELISA for anti-sperm antibody in serum.

    PubMed

    Lynch, D M; Leali, B A; Howe, S E

    1986-08-01

    An enzyme-linked immunosorbent assay (ELISA) that quantitates antisperm antibody in serum was compared with standard sperm agglutination and immobilization assays with the use of sera from 40 normal and 292 subfertile individuals. Quantitation of the assay was accomplished by standardizing assay parameters, including the incorporation of a standard reference curve, the number of whole target sperm, the optimal dilution of serum, the selection of microtiter plate, and the time and temperatures involved in the adsorption and incubation phases. With this method, the level of antisperm antibody binding to target sperm in 40 normal fertile individuals was found to be 2.3 (+/- 1.1 standard deviation [SD]) fg immunoglobulin (Ig)/sperm. An increased mean level of 7.4 +/- 3.7 fg Ig/sperm was determined in 84 infertile patients with positive agglutination and/or immobilization tests. In 208 individuals with negative agglutination and immobilization tests the mean concentration of antisperm antibody was 2.5 +/- 1.3 fg Ig/sperm. Postvasectomy patients assayed by this method had a mean Ig binding value of 7.1 +/- 2.4 fg Ig/sperm. The infertile group with positive agglutination and/or immobilization tests had a significantly higher mean antisperm antibody level than the normal fertile group, according to the Student's t-test for independent samples (P less than 0.001). This indirect serum-based assay reproducibly quantitates antisperm antibody binding to whole target sperm, suggests the normal and abnormal levels of antisperm antibody, and correlates with standard functional assays.

  3. Defining the next generation of Plasmodium vivax diagnostic tests for control and elimination: Target product profiles

    PubMed Central

    Ade, Maria Paz; Baird, J. Kevin; Cheng, Qin; Cunningham, Jane; Dhorda, Mehul; Drakeley, Chris; Felger, Ingrid; Gamboa, Dionicia; Harbers, Matthias; Herrera, Socrates; Lucchi, Naomi; Mayor, Alfredo; Mueller, Ivo; Sattabongkot, Jetsumon; Ratsimbason, Arsène; Richards, Jack; Tanner, Marcel; González, Iveth J.

    2017-01-01

    The global prevalence of malaria has decreased over the past fifteen years, but similar gains have not been realized against Plasmodium vivax because this species is less responsive to conventional malaria control interventions aimed principally at P. falciparum. Approximately half of all malaria cases outside of Africa are caused by P. vivax. This species places dormant forms in human liver that cause repeated clinical attacks without involving another mosquito bite. The diagnosis of acute patent P. vivax malaria relies primarily on light microscopy. Specific rapid diagnostic tests exist but typically perform relatively poorly compared to those for P. falciparum. Better diagnostic tests are needed for P. vivax. To guide their development, FIND, in collaboration with P. vivax experts, identified the specific diagnostic needs associated with this species and defined a series of three distinct target product profiles, each aimed at a particular diagnostic application: (i) point-of-care of acutely ill patients for clinical care purposes; (ii) point-of-care asymptomatic and otherwise sub-patent residents for public health purposes, e.g., mass screen and treat campaigns; and (iii) ultra-sensitive not point-of-care diagnosis for epidemiological research/surveillance purposes. This report presents and discusses the rationale for these P. vivax-specific diagnostic target product profiles. These contribute to the rational development of fit-for-purpose diagnostic tests suitable for the clinical management, control and elimination of P. vivax malaria. PMID:28369085

  4. Systematic evaluation of a targeted gene capture sequencing panel for molecular diagnosis of retinitis pigmentosa.

    PubMed

    Huang, Hui; Chen, Yanhua; Chen, Huishuang; Ma, Yuanyuan; Chiang, Pei-Wen; Zhong, Jing; Liu, Xuyang; Asan; Wu, Jing; Su, Yan; Li, Xin; Deng, Jianlian; Huang, Yingping; Zhang, Xinxin; Li, Yang; Fan, Ning; Wang, Ying; Tang, Lihui; Shen, Jinting; Chen, Meiyan; Zhang, Xiuqing; Te, Deng; Banerjee, Santasree; Liu, Hui; Qi, Ming; Yi, Xin

    2018-01-01

    Inherited eye diseases are major causes of vision loss in both children and adults. Inherited eye diseases are characterized by clinical variability and pronounced genetic heterogeneity. Genetic testing may provide an accurate diagnosis for ophthalmic genetic disorders and allow gene therapy for specific diseases. A targeted gene capture panel was designed to capture exons of 283 inherited eye disease genes including 58 known causative retinitis pigmentosa (RP) genes. 180 samples were tested with this panel, 68 were previously tested by Sanger sequencing. Systematic evaluation of our method and comprehensive molecular diagnosis were carried on 99 RP patients. 96.85% targeted regions were covered by at least 20 folds, the accuracy of variants detection was 99.994%. In 4 of the 68 samples previously tested by Sanger sequencing, mutations of other diseases not consisting with the clinical diagnosis were detected by next-generation sequencing (NGS) not Sanger. Among the 99 RP patients, 64 (64.6%) were detected with pathogenic mutations, while in 3 patients, it was inconsistent between molecular diagnosis and their initial clinical diagnosis. After revisiting, one patient's clinical diagnosis was reclassified. In addition, 3 patients were found carrying large deletions. We have systematically evaluated our method and compared it with Sanger sequencing, and have identified a large number of novel mutations in a cohort of 99 RP patients. The results showed a sufficient accuracy of our method and suggested the importance of molecular diagnosis in clinical diagnosis.

  5. Systematic evaluation of a targeted gene capture sequencing panel for molecular diagnosis of retinitis pigmentosa

    PubMed Central

    Ma, Yuanyuan; Chiang, Pei-Wen; Zhong, Jing; Liu, Xuyang; Asan; Wu, Jing; Su, Yan; Li, Xin; Deng, Jianlian; Huang, Yingping; Zhang, Xinxin; Li, Yang; Fan, Ning; Wang, Ying; Tang, Lihui; Shen, Jinting; Chen, Meiyan; Zhang, Xiuqing; Te, Deng; Banerjee, Santasree; Liu, Hui; Qi, Ming; Yi, Xin

    2018-01-01

    Background Inherited eye diseases are major causes of vision loss in both children and adults. Inherited eye diseases are characterized by clinical variability and pronounced genetic heterogeneity. Genetic testing may provide an accurate diagnosis for ophthalmic genetic disorders and allow gene therapy for specific diseases. Methods A targeted gene capture panel was designed to capture exons of 283 inherited eye disease genes including 58 known causative retinitis pigmentosa (RP) genes. 180 samples were tested with this panel, 68 were previously tested by Sanger sequencing. Systematic evaluation of our method and comprehensive molecular diagnosis were carried on 99 RP patients. Results 96.85% targeted regions were covered by at least 20 folds, the accuracy of variants detection was 99.994%. In 4 of the 68 samples previously tested by Sanger sequencing, mutations of other diseases not consisting with the clinical diagnosis were detected by next-generation sequencing (NGS) not Sanger. Among the 99 RP patients, 64 (64.6%) were detected with pathogenic mutations, while in 3 patients, it was inconsistent between molecular diagnosis and their initial clinical diagnosis. After revisiting, one patient’s clinical diagnosis was reclassified. In addition, 3 patients were found carrying large deletions. Conclusions We have systematically evaluated our method and compared it with Sanger sequencing, and have identified a large number of novel mutations in a cohort of 99 RP patients. The results showed a sufficient accuracy of our method and suggested the importance of molecular diagnosis in clinical diagnosis. PMID:29641573

  6. Towards frameless maskless SRS through real-time 6DoF robotic motion compensation.

    PubMed

    Belcher, Andrew H; Liu, Xinmin; Chmura, Steven; Yenice, Kamil; Wiersma, Rodney D

    2017-11-13

    Stereotactic radiosurgery (SRS) uses precise dose placement to treat conditions of the CNS. Frame-based SRS uses a metal head ring fixed to the patient's skull to provide high treatment accuracy, but patient comfort and clinical workflow may suffer. Frameless SRS, while potentially more convenient, may increase uncertainty of treatment accuracy and be physiologically confining to some patients. By incorporating highly precise robotics and advanced software algorithms into frameless treatments, we present a novel frameless and maskless SRS system where a robot provides real-time 6DoF head motion stabilization allowing positional accuracies to match or exceed those of traditional frame-based SRS. A 6DoF parallel kinematics robot was developed and integrated with a real-time infrared camera in a closed loop configuration. A novel compensation algorithm was developed based on an iterative closest-path correction approach. The robotic SRS system was tested on six volunteers, whose motion was monitored and compensated for in real-time over 15 min simulated treatments. The system's effectiveness in maintaining the target's 6DoF position within preset thresholds was determined by comparing volunteer head motion with and without compensation. Comparing corrected and uncorrected motion, the 6DoF robotic system showed an overall improvement factor of 21 in terms of maintaining target position within 0.5 mm and 0.5 degree thresholds. Although the system's effectiveness varied among the volunteers examined, for all volunteers tested the target position remained within the preset tolerances 99.0% of the time when robotic stabilization was used, compared to 4.7% without robotic stabilization. The pre-clinical robotic SRS compensation system was found to be effective at responding to sub-millimeter and sub-degree cranial motions for all volunteers examined. The system's success with volunteers has demonstrated its capability for implementation with frameless and maskless SRS treatments, potentially able to achieve the same or better treatment accuracies compared to traditional frame-based approaches.

  7. Children's Identification of Consonants in a Speech-Shaped Noise or a Two-Talker Masker

    ERIC Educational Resources Information Center

    Leibold, Lori J.; Buss, Emily

    2013-01-01

    Purpose: To evaluate child-adult differences for consonant identification in a noise or a 2-talker masker. Error patterns were compared across age and masker type to test the hypothesis that errors with the noise masker reflect limitations in the peripheral encoding of speech, whereas errors with the 2-talker masker reflect target-masker…

  8. Randomized Controlled Trial of Problem-Solving Therapy for Minor Depression in Home Care

    ERIC Educational Resources Information Center

    Gellis, Zvi D.; McGinty, Jean; Tierney, Lynda; Jordan, Cindy; Burton, Jean; Misener, Elizabeth

    2008-01-01

    Objective: Data are presented from a pilot research program initiated to develop, refine, and test the outcomes of problem-solving therapy that targets the needs of older adults with minor depression in home care settings. Method: A pilot randomized clinical trial compares the impact of problem-solving therapy for home care to treatment as usual…

  9. A Computer Assisted Reading Program, Targeting Struggling Readers in a Title I Elementary School: A Program Evaluation

    ERIC Educational Resources Information Center

    Roy, Jon F.

    2016-01-01

    This study examined the effectiveness of READ 180, a computer based reading intervention on Lexile reading levels, Standardized Test of Reading Achievement (STAR) score, and attendance rates students in grades 3-5 who participated in the READ 180 program. The study compared the Scholastic Reading Inventory (SRI) scores of each group administered…

  10. Blue and Black Cloth Targets: Effects of Size, Shape, and Color on Stable Fly (Diptera: Muscidae) Attraction.

    PubMed

    Hogsette, Jerome A; Foil, Lane D

    2018-04-02

    Stable fly management is challenging because of the fly's dispersal behavior and its tendency to remain on the host only while feeding. Optically attractive traps have been used to survey and sometimes reduce adult populations. Insecticide-treated blue and black cloth targets developed for tsetse fly management in Africa were found to be attractive to stable flies in the United States, and various evaluations were conducted in Louisiana and Florida. Tests using untreated targets were designed to answer questions about configuration, size, and color relative to efficacy and stability in high winds. Studies with electric grid targets and with targets paired with Olson traps showed cloth target color attraction in the following decreasing order: black > blue-black > blue. A solid black target is easier to make than a blue-black target because no sewing is involved. Attraction was not affected when flat 1-m2 targets were formed into cylinders, despite the limited view of the blue and black colors together. There was no reduction in attraction when the 1-m2 cylindrical targets were compared with smaller (63 × 30 cm high) cylindrical targets. In addition, there was no difference in attraction between the small blue-black, blue, and black targets. Significance of findings and implications of potential uses for treated targets are discussed. Target attraction was indicated by the numbers of stable flies captured on an Olson sticky trap placed 30 cm from the target. Although this system is adequate for field research, it greatly underestimates the actual numbers of stable flies attracted to treated targets.

  11. The sigma-2 receptor as a therapeutic target for drug delivery in triple negative breast cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makvandi, Mehran; Tilahun, Estifanos D.; Lieberman, Brian P.

    Background: Triple-negative breast cancer (TNBC) is associated with high relapse rates and increased mortality when compared with other breast cancer subtypes. In contrast to receptor positive breast cancers, there are no approved targeted therapies for TNBC. Identifying biomarkers for TNBC is of high importance for the advancement of patient care. The sigma-2 receptor has been shown to be overexpressed in triple negative breast cancer in vivo and has been characterized as a marker of proliferation. The aim of the present study was to define the sigma-2 receptor as a target for therapeutic drug delivery and biomarker in TNBC. Methods: Three TNBCmore » cell lines were evaluated: MDA-MB-231, HCC1937 and HCC1806. Sigma-2 compounds were tested for pharmacological properties specific to the sigma-2 receptor through competitive inhibition assays. Sigma-2 receptor expression was measured through radioligand receptor saturation studies. Drug sensitivity for taxol was compared to a sigma-2 targeting compound conjugated to a cytotoxic payload, SW IV-134. Cell viability was assessed after treatments for 2 or 48 h. Sigma-2 blockade was assessed to define sigma-2 mediated cytotoxicity of SW IV-134. Caspase 3/7 activation induced by SW IV-134 was measured at corresponding treatment time points. Results: SW IV-134 was the most potent compound tested in two of the three cell lines and was similarly effective in all three. MDA-MB-231 displayed a statistically significant higher sigma-2 receptor expression and also was the most sensitive cell line evaluated to SW IV-134. Conclusion: Targeting the sigma-2 receptor with a cytotoxic payload was effective in all the three cell lines evaluated and provides the proof of concept for future development of a therapeutic platform for the treatment of TNBC. - Highlights: • TNBC cells are sensitive to sigma-2 receptor targeted drug conjugate SW IV-134. • MDA-MB-231 displayed the highest amount of sigma-2 receptors and corresponded well with sensitivity. • The sigma-2 receptor is a potential biomarker in TNBC for prognosis and therapy.« less

  12. Interference correction by extracting the information of interference dominant regions: Application to near-infrared spectra

    NASA Astrophysics Data System (ADS)

    Bi, Yiming; Tang, Liang; Shan, Peng; Xie, Qiong; Hu, Yong; Peng, Silong; Tan, Jie; Li, Changwen

    2014-08-01

    Interference such as baseline drift and light scattering can degrade the model predictability in multivariate analysis of near-infrared (NIR) spectra. Usually interference can be represented by an additive and a multiplicative factor. In order to eliminate these interferences, correction parameters are needed to be estimated from spectra. However, the spectra are often mixed of physical light scattering effects and chemical light absorbance effects, making it difficult for parameter estimation. Herein, a novel algorithm was proposed to find a spectral region automatically that the interesting chemical absorbance and noise are low, that is, finding an interference dominant region (IDR). Based on the definition of IDR, a two-step method was proposed to find the optimal IDR and the corresponding correction parameters estimated from IDR. Finally, the correction was performed to the full spectral range using previously obtained parameters for the calibration set and test set, respectively. The method can be applied to multi target systems with one IDR suitable for all targeted analytes. Tested on two benchmark data sets of near-infrared spectra, the performance of the proposed method provided considerable improvement compared with full spectral estimation methods and comparable with other state-of-art methods.

  13. Modeling companion diagnostics in economic evaluations of targeted oncology therapies: systematic review and methodological checklist.

    PubMed

    Doble, Brett; Tan, Marcus; Harris, Anthony; Lorgelly, Paula

    2015-02-01

    The successful use of a targeted therapy is intrinsically linked to the ability of a companion diagnostic to correctly identify patients most likely to benefit from treatment. The aim of this study was to review the characteristics of companion diagnostics that are of importance for inclusion in an economic evaluation. Approaches for including these characteristics in model-based economic evaluations are compared with the intent to describe best practice methods. Five databases and government agency websites were searched to identify model-based economic evaluations comparing a companion diagnostic and subsequent treatment strategy to another alternative treatment strategy with model parameters for the sensitivity and specificity of the companion diagnostic (primary synthesis). Economic evaluations that limited model parameters for the companion diagnostic to only its cost were also identified (secondary synthesis). Quality was assessed using the Quality of Health Economic Studies instrument. 30 studies were included in the review (primary synthesis n = 12; secondary synthesis n = 18). Incremental cost-effectiveness ratios may be lower when the only parameter for the companion diagnostic included in a model is the cost of testing. Incorporating the test's accuracy in addition to its cost may be a more appropriate methodological approach. Altering the prevalence of the genetic biomarker, specific population tested, type of test, test accuracy and timing/sequence of multiple tests can all impact overall model results. The impact of altering a test's threshold for positivity is unknown as it was not addressed in any of the included studies. Additional quality criteria as outlined in our methodological checklist should be considered due to the shortcomings of standard quality assessment tools in differentiating studies that incorporate important test-related characteristics and those that do not. There is a need to refine methods for incorporating the characteristics of companion diagnostics into model-based economic evaluations to ensure consistent and transparent reimbursement decisions are made.

  14. IT-25DEVELOPMENTALLY REGULATED ANTIGENS FOR IMMUNOLOGIC TARGETING OF MEDULLOBLASTOMA SUBTYPES

    PubMed Central

    Pham, Christina; Flores, Catherine; Pei, Yanxin; Wechsler-Reya, Robert; Mitchell, Duane

    2014-01-01

    INTRODUCTION: Medulloblastoma (MB) remains incurable in one third of patients despite aggressive multi-modality standard therapies. Immunotherapy presents a promising alternative by specifically targeting cancer cells. To date, there have been no successful immunologic applications targeting MB. Emerging evidence from integrated genomic studies has suggested MB variants arise from deregulation of pathways affecting proliferation of progenitor cell populations within the developing cerebellum. Using total embryonic RNA as a source of tumor rejection antigens is attractive because it can be delivered as a single vaccine, target both known and unknown fetal proteins, and can be refined to preferentially treat distinct MB subtypes. METHODS: We have created two transplantable, syngeneic animal MB models recapitulating human SHH and Group 3 variants to investigate the immunologic targeting of different MB subtypes. We generated T cells specific to the developing mouse cerebellum (P5) and tested their reactivity to target cells pulsed with total RNA from two MB subtypes and the normal brain. Immune responses were evaluated by measuring cytokine secretion following re-stimulation of activated T cells with both normal and tumor cell targets. In vivo antitumor efficacy was also tested in survival studies of intracranial tumor-bearing animals. RESULTS: We generated T cells specific to the developing cerebellum in vitro, confirming the immunogenicity of developmentally regulated antigens. Additionally, we have shown that developmental antigen-specific T cells produce high levels of Th1-type cytokines in response to tumor cells of two immunologically distinct subtypes of MB. Interestingly, developmental antigen specific T cells do not show cross reactivity with the normal brain or subsequent stages of the developing brain after P5. Targeting developmental antigens also conferred a significant survival benefit in a treatment model of Group 3 tumor bearing animals. CONCLUSIONS: Developmental antigens can safely target multiple MB subtypes with equal effectiveness compared to previously established total tumor strategies.

  15. Cholesterol-modified poly(lactide-co-glycolide) nanoparticles for tumor-targeted drug delivery.

    PubMed

    Lee, Jeong-Jun; Lee, Song Yi; Park, Ju-Hwan; Kim, Dae-Duk; Cho, Hyun-Jong

    2016-07-25

    Poly(lactide-co-glycolide)-cholesterol (PLGA-C)-based nanoparticles (NPs) were developed for the tumor-targeted delivery of curcumin (CUR). PLGA-C/CUR NPs with ∼200nm mean diameter, narrow size distribution, and neutral zeta potential were fabricated by a modified emulsification-solvent evaporation method. The existence of cholesterol moiety in PLGA-C copolymer was confirmed by proton nuclear magnetic resonance ((1)H NMR) analysis. In vitro stability of developed NPs after 24h incubation was confirmed in phosphate buffered saline (PBS) and serum media. Sustained (∼6days) and pH-responsive drug release profiles from PLGA-C NPs were presented. Blank PLGA and PLGA-C NPs exhibited a negligible cytotoxicity in Hep-2 (human laryngeal carcinoma) cells in the tested concentration range. According to the results of flow cytometry and confocal laser scanning microscopy (CLSM) studies, PLGA-C NPs presented an improved cellular accumulation efficiency, compared to PLGA NPs, in Hep-2 cells. Enhanced in vivo tumor targetability of PLGA-C NPs, compared to PLGA NPs, in Hep-2 tumor-xenografted mouse model was also verified by a real-time near-infrared fluorescence (NIRF) imaging study. Developed PLGA-C NPs may be a candidate of efficient and biocompatible nanosystems for tumor-targeted drug delivery and cancer imaging. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. The "common good" phenomenon: Why similarities are positive and differences are negative.

    PubMed

    Alves, Hans; Koch, Alex; Unkelbach, Christian

    2017-04-01

    Positive attributes are more prevalent than negative attributes in the social environment. From this basic assumption, 2 implications that have been overlooked thus far: Positive compared with negative attributes are more likely to be shared by individuals, and people's shared attributes (similarities) are more positive than their unshared attributes (differences). Consequently, similarity-based comparisons should lead to more positive evaluations than difference-based comparisons. We formalized our probabilistic reasoning in a model and tested its predictions in a simulation and 8 experiments (N = 1,181). When participants generated traits about 2 target persons, positive compared with negative traits were more likely to be shared by the targets (Experiment 1a) and by other participants' targets (Experiment 1b). Conversely, searching for targets' shared traits resulted in more positive traits than searching for unshared traits (Experiments 2, 4a, and 4b). In addition, positive traits were more accessible than negative traits among shared traits but not among unshared traits (Experiment 3). Finally, shared traits were only more positive when positive traits were indeed prevalent (Experiments 5 and 6). The current framework has a number of implications for comparison processes and provides a new interpretation of well-known evaluative asymmetries such as intergroup bias and self-superiority effects. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  17. Hydrocode predictions of collisional outcomes: Effects of target size

    NASA Technical Reports Server (NTRS)

    Ryan, Eileen V.; Asphaug, Erik; Melosh, H. J.

    1991-01-01

    Traditionally, laboratory impact experiments, designed to simulate asteroid collisions, attempted to establish a predictive capability for collisional outcomes given a particular set of initial conditions. Unfortunately, laboratory experiments are restricted to using targets considerably smaller than the modelled objects. It is therefore necessary to develop some methodology for extrapolating the extensive experimental results to the size regime of interest. Results are reported obtained through the use of two dimensional hydrocode based on 2-D SALE and modified to include strength effects and the fragmentation equations. The hydrocode was tested by comparing its predictions for post-impact fragment size distributions to those observed in laboratory impact experiments.

  18. Application of the Integral Theory of Impact to the Qualification of Materials and the Development of a Simplified Rod Penetrator Model

    DTIC Science & Technology

    1978-11-01

    Kevlar target. This composite is a woven fabric produced by DuPont and consists of aramid ( Kevlar ) fibers treated with an epoxy resin and molded into...between layers was employed. Kevlar has a value of E~p comparable to steel and a large component of E~e D. Summary of Qualification Tests A summary of...34 STEEL BALL 0 .156" STEEL BALL1 p/dO X.k WC ball I theory Steel ball theory .0 20 100 1000 Velocity, ft/sec Figure 17 34 KEVLAR TARGET RIGID, EPOXY RESIN

  19. Fast Boundary Element Method for acoustics with the Sparse Cardinal Sine Decomposition

    NASA Astrophysics Data System (ADS)

    Alouges, François; Aussal, Matthieu; Parolin, Emile

    2017-07-01

    This paper presents the newly proposed method Sparse Cardinal Sine Decomposition that allows fast convolution on unstructured grids. We focus on its use when coupled with finite element techniques to solve acoustic problems with the (compressed) Boundary Element Method. In addition, we also compare the computational performances of two equivalent Matlab® and Python implementations of the method. We show validation test cases in order to assess the precision of the approach. Eventually, the performance of the method is illustrated by the computation of the acoustic target strength of a realistic submarine from the Benchmark Target Strength Simulation international workshop.

  20. Evaluation of pediatric ATD biofidelity as compared to child volunteers in low-speed far-side oblique and lateral impacts.

    PubMed

    Seacrist, Thomas; Locey, Caitlin M; Mathews, Emily A; Jones, Dakota L; Balasubramanian, Sriram; Maltese, Matthew R; Arbogast, Kristy B

    2014-01-01

    Motor vehicle crashes are a leading cause of injury and mortality for children. Mitigation of these injuries requires biofidelic anthropomorphic test devices (ATDs) to design and evaluate automotive safety systems. Effective countermeasures exist for frontal and near-side impacts but are limited for far-side impacts. Consequently, far-side impacts represent increased injury and mortality rates compared to frontal impacts. Thus, the objective of this study was to evaluate the biofidelity of the Hybrid III and Q-series pediatric ATDs in low-speed far-side impacts, with and without shoulder belt pretightening. Low-speed (2 g) far-side oblique (60°) and lateral (90°) sled tests were conducted using the Hybrid III and Q-series 6- and 10-year-old ATDs. ATDs were restrained by a lap and shoulder belt equipped with a precrash belt pretightener. Photoreflective targets were attached to the head, spine, shoulders, and sternum. ATDs were exposed to 8 low-speed sled tests: 2 oblique nontightened, 2 oblique pretightened, 2 lateral nontightened, 2 lateral pretightened. ATDs were compared with previously collected 9- to 11-year-old (n=10) volunteer data and newly collected 6- to 8-year-old volunteer data (n=7) tested with similar methods. Kinematic data were collected from a 3D target tracking system. Metrics of comparison included excursion, seat belt and seat pan reaction loads, belt-to-torso angle, and shoulder belt slip-out. The ATDs exhibited increased lateral excursion of the head top, C4, and T1 as well as increased downward excursion of the head top compared to the volunteers. Volunteers exhibited greater forward excursion than the ATDs in oblique nontightened impacts. These kinematics correspond to increased shoulder belt slip-out for the ATDs in oblique tests (ATDs=90%; volunteers=36%). Contrarily, similar shoulder belt slip-out was observed between ATDs and volunteers in lateral impacts (ATDs=80%; volunteers=78%). In pretightened impacts, the ATDs exhibited reduced lateral excursion and torso roll-out angle compared to the volunteers. In general, the ATDs overestimated lateral excursion in both impact directions, while underestimating forward excursion of the head and neck in oblique impacts compared to the pediatric volunteers. This was primarily due to pendulum-like lateral bending of the entire ATD torso compared to translation of the thorax relative to the abdomen prior to the lateral bending of the upper torso in the volunteers, likely due to the multisegmented spinal column in the volunteers. Additionally, the effect of belt pretightening on occupant kinematics was greater for the ATDs than the volunteers.

  1. Evaluation of radiosurgery techniques–Cone-based linac radiosurgery vs tomotherapy-based radiosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yip, Ho Yin, E-mail: hoyinyip@yahoo.com.hk; Mui, Wing Lun A.; Lee, Joseph W.Y.

    2013-07-01

    Performances of radiosurgery of intracranial lesions between cone-based Linac system and Tomotherapy-based system were compared in terms of dosimetry and time. Twelve patients with single intracranial lesion treated with cone-based Linac radiosurgery system from 2005 to 2009 were replanned for Tomotherapy-based radiosurgery treatment. The conformity index, homogeneity index (HI), and gradient score index (GSI) of each case was calculated. The Wilcoxon matched-pair test was used to compare the 3 indices between both systems. The cases with regular target (n = 6) and those with irregular target (n = 6) were further analyzed separately. The estimated treatment time between both systemsmore » was also compared. Significant differences were found in HI (p = 0.05) and in GSI (p = 0.03) for the whole group. Cone-based radiosurgery was better in GSI whereas Tomotherapy-based radiosurgery was better in HI. Cone-based radiosurgery was better in conformity index (p = 0.03) and GSI (p = 0.03) for regular targets, whereas Tomotherapy-based radiosurgery system performed significantly better in HI (p = 0.03) for irregular targets. The estimated total treatment time for Tomotherapy-based radiosurgery ranged from 24 minutes to 35 minutes, including 15 minutes of pretreatment megavoltage computed tomography (MVCT) and image registration, whereas that for cone-based radiosurgery ranged from 15 minutes for 1 isocenter to 75 minutes for 5 isocenters. As a rule of thumb, Tomotherapy-based radiosurgery system should be the first-line treatment for irregular lesions because of better dose homogeneity and shorter treatment time. Cone-based Linac radiosurgery system should be the treatment of choice for regular targets because of the better dose conformity, rapid dose fall-off, and reasonable treatment time.« less

  2. How does intentionality of encoding affect memory for episodic information?

    PubMed Central

    Craig, Michael; Butterworth, Karla; Nilsson, Jonna; Hamilton, Colin J.; Gallagher, Peter

    2016-01-01

    Episodic memory enables the detailed and vivid recall of past events, including target and wider contextual information. In this paper, we investigated whether/how encoding intentionality affects the retention of target and contextual episodic information from a novel experience. Healthy adults performed (1) a What-Where-When (WWW) episodic memory task involving the hiding and delayed recall of a number of items (what) in different locations (where) in temporally distinct sessions (when) and (2) unexpected tests probing memory for wider contextual information from the WWW task. Critically, some participants were informed that memory for WWW information would be subsequently probed (intentional group), while this came as a surprise for others (incidental group). The probing of contextual information came as a surprise for all participants. Participants also performed several measures of episodic and nonepisodic cognition from which common episodic and nonepisodic factors were extracted. Memory for target (WWW) and contextual information was superior in the intentional group compared with the incidental group. Memory for target and contextual information was unrelated to factors of nonepisodic cognition, irrespective of encoding intentionality. In addition, memory for target information was unrelated to factors of episodic cognition. However, memory for wider contextual information was related to some factors of episodic cognition, and these relationships differed between the intentional and incidental groups. Our results lead us to propose the hypothesis that intentional encoding of episodic information increases the coherence of the representation of the context in which the episode took place. This hypothesis remains to be tested. PMID:27918286

  3. Testing a simplified method for measuring velocity integration in saccades using a manipulation of target contrast.

    PubMed

    Etchells, Peter J; Benton, Christopher P; Ludwig, Casimir J H; Gilchrist, Iain D

    2011-01-01

    A growing number of studies in vision research employ analyses of how perturbations in visual stimuli influence behavior on single trials. Recently, we have developed a method along such lines to assess the time course over which object velocity information is extracted on a trial-by-trial basis in order to produce an accurate intercepting saccade to a moving target. Here, we present a simplified version of this methodology, and use it to investigate how changes in stimulus contrast affect the temporal velocity integration window used when generating saccades to moving targets. Observers generated saccades to one of two moving targets which were presented at high (80%) or low (7.5%) contrast. In 50% of trials, target velocity stepped up or down after a variable interval after the saccadic go signal. The extent to which the saccade endpoint can be accounted for as a weighted combination of the pre- or post-step velocities allows for identification of the temporal velocity integration window. Our results show that the temporal integration window takes longer to peak in the low when compared to high contrast condition. By enabling the assessment of how information such as changes in velocity can be used in the programming of a saccadic eye movement on single trials, this study describes and tests a novel methodology with which to look at the internal processing mechanisms that transform sensory visual inputs into oculomotor outputs.

  4. Signs of depth-luminance covariance in 3-D cluttered scenes.

    PubMed

    Scaccia, Milena; Langer, Michael S

    2018-03-01

    In three-dimensional (3-D) cluttered scenes such as foliage, deeper surfaces often are more shadowed and hence darker, and so depth and luminance often have negative covariance. We examined whether the sign of depth-luminance covariance plays a role in depth perception in 3-D clutter. We compared scenes rendered with negative and positive depth-luminance covariance where positive covariance means that deeper surfaces are brighter and negative covariance means deeper surfaces are darker. For each scene, the sign of the depth-luminance covariance was given by occlusion cues. We tested whether subjects could use this sign information to judge the depth order of two target surfaces embedded in 3-D clutter. The clutter consisted of distractor surfaces that were randomly distributed in a 3-D volume. We tested three independent variables: the sign of the depth-luminance covariance, the colors of the targets and distractors, and the background luminance. An analysis of variance showed two main effects: Subjects performed better when the deeper surfaces were darker and when the color of the target surfaces was the same as the color of the distractors. There was also a strong interaction: Subjects performed better under a negative depth-luminance covariance condition when targets and distractors had different colors than when they had the same color. Our results are consistent with a "dark means deep" rule, but the use of this rule depends on the similarity between the color of the targets and color of the 3-D clutter.

  5. Eye Choice for Acquisition of Targets in Alternating Strabismus

    PubMed Central

    Economides, John R.; Adams, Daniel L.

    2014-01-01

    In strabismus, potentially either eye can inform the brain about the location of a target so that an accurate saccade can be made. Sixteen human subjects with alternating exotropia were tested dichoptically while viewing stimuli on a tangent screen. Each trial began with a fixation cross visible to only one eye. After the subject fixated the cross, a peripheral target visible to only one eye flashed briefly. The subject's task was to look at it. As a rule, the eye to which the target was presented was the eye that acquired the target. However, when stimuli were presented in the far nasal visual field, subjects occasionally performed a “crossover” saccade by placing the other eye on the target. This strategy avoided the need to make a large adducting saccade. In such cases, information about target location was obtained by one eye and used to program a saccade for the other eye, with a corresponding latency increase. In 10/16 subjects, targets were presented on some trials to both eyes. Binocular sensory maps were also compiled to delineate the portions of the visual scene perceived with each eye. These maps were compared with subjects' pattern of eye choice for target acquisition. There was a correspondence between suppression scotoma maps and the eye used to acquire peripheral targets. In other words, targets were fixated by the eye used to perceive them. These studies reveal how patients with alternating strabismus, despite eye misalignment, manage to localize and capture visual targets in their environment. PMID:25355212

  6. Target innervation is necessary for neuronal polyploidization in the terrestrial slug Limax.

    PubMed

    Matsuo, Ryota; Yamagishi, Miki; Wakiya, Kyoko; Tanaka, Yoko; Ito, Etsuro

    2013-05-30

    The brain of gastropod mollusks contains many giant neurons with polyploid genomic DNAs. Such DNAs are generated through repeated DNA endoreplication during body growth. However, it is not known what triggers DNA endoreplication in neurons. There are two possibilities: (1) DNAs are replicated in response to some unknown molecules in the hemolymph that reflect the nutritive status of the animal; or (2) DNAs are replicated in response to some unknown factors that are retrogradely transported through axons from the innervated target organs. We first tested whether hemolymph with rich nutrition could induce DNA endoreplication. We tested whether the transplanted brain exhibits enhanced DNA endoreplication like an endogenous brain does when transplanted into the homocoel of the body of a slug whose body growth is promoted by an increased food supply. However, no enhancement was observed in the frequency of DNA endoreplication when we compared the transplanted brains in the growth-promoted and growth-suppressed host slugs, suggesting that the humoral environment is irrelevant to triggering the body growth-dependent DNA endoreplication. Next, we tested the requirement of target innervation by surgically dissecting a unilateral posterior pedal nerve of an endogenous brain. Substantially lower number of neurons exhibited DNA endoreplication in the pedal ganglion ipsilateral to the dissected nerve. These results support the view that enhanced DNA endoreplication is mediated by target innervation and is not brought about through the direct effect of humoral factors in the hemolymph during body growth. © 2013 Wiley Periodicals, Inc. Develop Neurobiol, 2013. Copyright © 2013 Wiley Periodicals, Inc.

  7. Low load exercises targeting the gluteal muscle group acutely enhance explosive power output in elite athletes.

    PubMed

    Crow, Justin F; Buttifant, David; Kearny, Simon G; Hrysomallis, Con

    2012-02-01

    The purpose of this study was to investigate the acute effect of 3 warm-up protocols on peak power production during countermovement jump (CMJ) testing. The intention was to devise and compare practical protocols that could be applied as a warm-up immediately before competition matches or weight training sessions. A group of 22 elite Australian Rules Football players performed 3 different warm-up protocols over 3 testing sessions in a randomized order. The protocols included a series of low load exercises targeting the gluteal muscle group (GM-P), a whole-body vibration (WBV) protocol (WBV-P) wherein the subjects stood on a platform vibrating at 30 Hz for 45 seconds, and a no-warm-up condition (CON). The CMJ testing was performed within 5 minutes of each warm-up protocol on an unloaded Smith machine using a linear encoder to measure peak power output. Peak power production was significantly greater after the GM-P than after both the CON (p < 0.05) and WBV-P (p < 0.01). No significant differences in peak power production were detected between the WBV-P and CON. These results have demonstrated that a low load exercise protocol targeting the gluteal muscle group is effective at acutely enhancing peak power output in elite athletes. The mechanisms for the observed improvements are unclear and warrant further investigation. Coaches may consider incorporating low load exercises targeting the gluteal muscle group into the warm-up of athletes competing in sports requiring explosive power output of the lower limbs.

  8. An improved SELEX technique for selection of DNA aptamers binding to M-type 11 of Streptococcus pyogenes.

    PubMed

    Hamula, Camille L A; Peng, Hanyong; Wang, Zhixin; Tyrrell, Gregory J; Li, Xing-Fang; Le, X Chris

    2016-03-15

    Streptococcus pyogenes is a clinically important pathogen consisting of various serotypes determined by different M proteins expressed on the cell surface. The M type is therefore a useful marker to monitor the spread of invasive S. pyogenes in a population. Serotyping and nucleic acid amplification/sequencing methods for the identification of M types are laborious, inconsistent, and usually confined to reference laboratories. The primary objective of this work is to develop a technique that enables generation of aptamers binding to specific M-types of S. pyogenes. We describe here an in vitro technique that directly used live bacterial cells and the Systematic Evolution of Ligands by Exponential Enrichment (SELEX) strategy. Live S. pyogenes cells were incubated with DNA libraries consisting of 40-nucleotides randomized sequences. Those sequences that bound to the cells were separated, amplified using polymerase chain reaction (PCR), purified using gel electrophoresis, and served as the input DNA pool for the next round of SELEX selection. A specially designed forward primer containing extended polyA20/5Sp9 facilitated gel electrophoresis purification of ssDNA after PCR amplification. A counter-selection step using non-target cells was introduced to improve selectivity. DNA libraries of different starting sequence diversity (10(16) and 10(14)) were compared. Aptamer pools from each round of selection were tested for their binding to the target and non-target cells using flow cytometry. Selected aptamer pools were then cloned and sequenced. Individual aptamer sequences were screened on the basis of their binding to the 10 M-types that were used as targets. Aptamer pools obtained from SELEX rounds 5-8 showed high affinity to the target S. pyogenes cells. Tests against non-target Streptococcus bovis, Streptococcus pneumoniae, and Enterococcus species demonstrated selectivity of these aptamers for binding to S. pyogenes. Several aptamer sequences were found to bind preferentially to the M11 M-type of S. pyogenes. Estimated binding dissociation constants (Kd) were in the low nanomolar range for the M11 specific sequences; for example, sequence E-CA20 had a Kd of 7±1 nM. These affinities are comparable to those of a monoclonal antibody. The improved bacterial cell-SELEX technique is successful in generating aptamers selective for S. pyogenes and some of its M-types. These aptamers are potentially useful for detecting S. pyogenes, achieving binding profiles of the various M-types, and developing new M-typing technologies for non-specialized laboratories or point-of-care testing. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Eccentricity Effects on the Efficiency of Attentional Networks: Evidence From a Modified Attention Network Test.

    PubMed

    Wang, Bin; Zhao, Jingjing; Wu, Zheng; Shang, Wei; Xiang, Jie; Cao, Rui; Li, Haifang; Chen, Junjie; Zhang, Hui; Yan, Ting

    2016-07-05

    The effects of eccentricity on the attentional modulation of visual discrimination have been widely studied; however, the substrate of this complex phenomenon is poorly understood. Here, we provided a measure of the effects of eccentricity on three attentional networks: alerting, orienting, and executive attention. Participants (N = 63) were tested with a modified attention network test that included an additional eccentricity variation; this test allowed us to investigate the efficiency of the attentional networks at near and far eccentricities. Compared with targets at the near eccentricity, targets at the far eccentricity generally elicited significantly longer reaction times. We also found the far eccentricity was associated with smaller orienting effect scores and larger executive control scores than the near eccentricity. Interestingly, at the near eccentricity, executive control scores were larger when the spatial information was neutral (no cue, center cue, and double cue), but at the far eccentricity, the scores were larger when the spatial information was valid (spatial cue). We propose that the allocation of attentional resources differed among these cue conditions and influenced the interference caused by conflicting information. © The Author(s) 2016.

  10. Protective effects of cultured and fermented ginseng extracts against scopolamine-induced memory loss in a mouse model.

    PubMed

    Han, Song-Hee; Kim, Sung-June; Yun, Young Won; Nam, Sang Yoon; Lee, Hu-Jang; Lee, Beom-Jun

    2018-03-01

    This study was performed to investigate the effect of a concentrate of fermented wild ginseng root culture (HLJG0701) on memory improvement in the scopolamine (SPL)-induced memory-deficient mouse model. Eight-week-old male ICR mice were used to evaluate the protective effect of HLJG0701 against the SPL-induced memory loss animal model. The Morris water maze test, which measures hippocampus-dependent learning ability, and the Y-maze test, a short-term memory assessment test, were performed and related markers were analyzed. HLJG0701-treated groups displayed significantly reduced acetylcholinesterase activity and increased acetylcholine level compared with the SPL-administered group (SPL-G) ( P <0.05). In the Y-maze test, the spontaneous alternation in al HLJG0711-treated groups was significantly increased compared with that in SPL-G ( P <0.05). In the Morris water maze test, the escape latency and time spent in the target quadrant in all HLJG0701-treated groups were significantly decreased and increased, respectively, compared with those in SPL-G ( P <0.05). In addition, the brain-derived neurotrophic factor level in groups treated with HLJG0701 300 and 600 mg/kg body weight was significantly increased compared with that in SPL-G ( P <0.05). These results suggest that the HLJG0701 may protect against memory loss by inhibiting acetylcholinesterase activity and preventing acetylcholine deficiency.

  11. Robotic path-finding in inverse treatment planning for stereotactic radiosurgery with continuous dose delivery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vandewouw, Marlee M., E-mail: marleev@mie.utoronto

    Purpose: Continuous dose delivery in radiation therapy treatments has been shown to decrease total treatment time while improving the dose conformity and distribution homogeneity over the conventional step-and-shoot approach. The authors develop an inverse treatment planning method for Gamma Knife® Perfexion™ that continuously delivers dose along a path in the target. Methods: The authors’ method is comprised of two steps: find a path within the target, then solve a mixed integer optimization model to find the optimal collimator configurations and durations along the selected path. Robotic path-finding techniques, specifically, simultaneous localization and mapping (SLAM) using an extended Kalman filter, aremore » used to obtain a path that travels sufficiently close to selected isocentre locations. SLAM is novelly extended to explore a 3D, discrete environment, which is the target discretized into voxels. Further novel extensions are incorporated into the steering mechanism to account for target geometry. Results: The SLAM method was tested on seven clinical cases and compared to clinical, Hamiltonian path continuous delivery, and inverse step-and-shoot treatment plans. The SLAM approach improved dose metrics compared to the clinical plans and Hamiltonian path continuous delivery plans. Beam-on times improved over clinical plans, and had mixed performance compared to Hamiltonian path continuous plans. The SLAM method is also shown to be robust to path selection inaccuracies, isocentre selection, and dose distribution. Conclusions: The SLAM method for continuous delivery provides decreased total treatment time and increased treatment quality compared to both clinical and inverse step-and-shoot plans, and outperforms existing path methods in treatment quality. It also accounts for uncertainty in treatment planning by accommodating inaccuracies.« less

  12. Dosimetric comparison between cone/Iris-based and InCise MLC-based CyberKnife plans for single and multiple brain metastases.

    PubMed

    Jang, Si Young; Lalonde, Ron; Ozhasoglu, Cihat; Burton, Steven; Heron, Dwight; Huq, M Saiful

    2016-09-08

    We performed an evaluation of the CyberKnife InCise MLC by comparing plan qualities for single and multiple brain lesions generated using the first version of InCise MLC, fixed cone, and Iris collimators. We also investigated differences in delivery efficiency among the three collimators. Twenty-four patients with single or multiple brain mets treated previously in our clinic on a CyberKnife M6 using cone/Iris collimators were selected for this study. Treatment plans were generated for all lesions using the InCise MLC. Number of monitor units, delivery time, target coverage, conformity index, and dose falloff were compared between MLC- and clinical cone/Iris-based plans. Statistical analysis was performed using the non-parametric Wilcoxon-Mann-Whitney signed-rank test. The planning accuracy of the MLC-based plans was validated using chamber and film measurements. The InCise MLC-based plans achieved mean dose and target coverage comparable to the cone/Iris-based plans. Although the conformity indices of the MLC-based plans were slightly higher than those of the cone/Iris-based plans, beam delivery time for the MLC-based plans was shorter by 30% ~ 40%. For smaller targets or cases with OARs located close to or abutting target volumes, MLC-based plans provided inferior dose conformity compared to cone/Iris-based plans. The QA results of MLC-based plans were within 5% absolute dose difference with over 90% gamma passing rate using 2%/2 mm gamma criteria. The first version of InCise MLC could be a useful delivery modality, especially for clinical situations for which delivery time is a limiting factor or for multitarget cases. © 2016 The Authors.

  13. Real-Time Target Motion Animation for Missile Warning System Testing

    DTIC Science & Technology

    2006-04-01

    T. Perkins, R. Sundberg, J. Cordell, Z. Tun , and M. Owen, Real-time Target Motion Animation for Missile Warning System Testing, Proc. SPIE Vol 6208...Z39-18 Real-time target motion animation for missile warning system testing Timothy Perkins*a, Robert Sundberga, John Cordellb, Zaw Tunb, Mark

  14. 29 mm Diameter Target Test Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woloshun, Keith Albert; Olivas, Eric Richard; Dale, Gregory E.

    After numerous delays, the test of the 29 mm diameter target was conducted on 8/18/2017. The complete target design report, dated 8/15/2016, is reproduced below for completeness. This describes in detail the 10 disk target with varying thickness disks. The report presents and discusses the test results. In brief summary, there appears to have been multiple instrumentation errors. Measured temperatures, pressures and IR camera window temperature measurement are all suspect. All tests were done at 35 MeV, with 171 μA current, or 6 kW of beam power.

  15. Biofidelity assessment of the 6-year-old ATDs in lateral impact.

    PubMed

    Yaek, J L; Li, Y; Lemanski, P J; Begeman, P C; Rouhana, S W; Cavanaugh, J M

    2016-07-03

    The objective of this study was to assess and compare the current lateral impact biofidelity of the shoulder, thorax, abdomen, and pelvis of the Q6, Q6s, and Hybrid III (HIII) 6-year-old anthropomorphic test devices (ATDs) through lateral impact testing. A series of lateral impact pendulum tests, vertical drop tests, and Wayne State University (WSU) sled tests was performed, based on the procedures detailed in ISO/TR 9790 (1999) and scaling to the 6-year-old using Irwin et al. ( 2002 ). The HIII used in this study was tested with the Ford-designed abdomen described in Rouhana ( 2006 ) and Elhagediab et al. ( 2006 ). The data collected from the 3 different ATDs were filtered using SAE J211 (SAE International 2003 ), aligned using the methodology described by Donnelly and Moorhouse ( 2012 ), and compared for each body region tested (shoulder, thorax, abdomen, and pelvis). The biofidelity performance in lateral impact for the 3 ATDs was assessed against the scaled biofidelity targets published in Irwin et al. ( 2002 ), the abdominal biofidelity target suggested in van Ratingen et al. ( 1997 ), and the biofidelity targets published in Rhule et al. ( 2013 ). Regional and overall biofidelity rankings for each of the 3 ATDs were performed using both the ISO 9790 biofidelity rating system (ISO/TR 9790 1999) and the NHTSA's external biofidelity ranking system (BRS; Rhule et al. 2013 ). All 3 6-year-old ATD's pelvises were rated as least biofidelic of the 4 body regions tested, based on both the ISO and BRS biofidelity rating systems, followed by the shoulder and abdomen, respectively. The thorax of all 3 ATDs was rated as the most biofidelic body region using the aforementioned biofidelity rating systems. The HIII 6-year-old ATD was rated last in overall biofidelity of the 3 tested ATDs, based on both rating systems. The Q6s ATD was rated as having the best overall biofidelity using both rating systems. All 3 ATDs are more biofidelic in the thorax and abdomen than the shoulder and pelvis, with the pelvis being the least biofidelic of all 4 tested body regions. None of the 3 tested 6-year-old ATDs had an overall ranking of 2.0 or less, based on the BRS ranking. Therefore, it is expected that none of the 3 ATDs would mechanically respond like a postmortem human subject (PMHS) in a lateral impact crash test based on this ranking system. With respect to the ISO biofidelity rating, the HIII dummy would be considered unsuitable and the Q-series dummies would be considered marginal for assessing side impact occupant protection.

  16. Positive Imagery-Based Cognitive Bias Modification as a Web-Based Treatment Tool for Depressed Adults

    PubMed Central

    Blackwell, Simon E.; Browning, Michael; Mathews, Andrew; Pictet, Arnaud; Welch, James; Davies, Jim; Watson, Peter; Geddes, John R.

    2015-01-01

    Depression is a global health problem requiring treatment innovation. Targeting neglected cognitive aspects may provide a useful route. We tested a cognitive-training paradigm using positive mental imagery (imagery cognitive bias modification, imagery CBM), developed via experimental psychopathology studies, in a randomized controlled trial. Training was delivered via the Internet to 150 individuals with current major depression. Unexpectedly, there was no significant advantage for imagery CBM compared with a closely matched control for depression symptoms as a whole in the full sample. In exploratory analyses, compared with the control, imagery CBM significantly improved anhedonia over the intervention and improved depression symptoms as a whole for those participants with fewer than five episodes of depression and those who engaged to a threshold level of imagery. Results suggest avenues for improving imagery CBM to inform low-intensity treatment tools for depression. Anhedonia may be a useful treatment target for future work. PMID:25984421

  17. Lethal violence and psychosis: a clinical profile.

    PubMed

    Nestor, P G; Haycock, J; Doiron, S; Kelly, J; Kelly, D

    1995-01-01

    To investigate the relationship between lethal violence and psychosis, the authors examined symptomatology, neuropsychological functioning, and the nature of perpetrator-victim relationships of patients with psychotic disorders who were committed to a forensic psychiatric hospital following violent, primarily criminal behavior. A severely violent group, composed primarily of psychotic patients charged with murder, was compared with a less severely violent group that was composed primarily of psychotic patients involved with property crimes. As compared with the less violent group, the severely violent group was more likely to have delusional beliefs about specific personal targets and to have delusions about significant others being replaced by impostors. These beliefs were accompanied by higher scores on neuropsychological tests of intellectual and academic abilities. A high number of their blood relatives were victims of psychotic murder. These results indicated that a higher incidence of lethal or near lethal acts of violence may characterize intellectually intact but psychotic individuals with organize delusions involving personal, accessible targets.

  18. Multispectral image fusion for target detection

    NASA Astrophysics Data System (ADS)

    Leviner, Marom; Maltz, Masha

    2009-09-01

    Various different methods to perform multi-spectral image fusion have been suggested, mostly on the pixel level. However, the jury is still out on the benefits of a fused image compared to its source images. We present here a new multi-spectral image fusion method, multi-spectral segmentation fusion (MSSF), which uses a feature level processing paradigm. To test our method, we compared human observer performance in an experiment using MSSF against two established methods: Averaging and Principle Components Analysis (PCA), and against its two source bands, visible and infrared. The task that we studied was: target detection in the cluttered environment. MSSF proved superior to the other fusion methods. Based on these findings, current speculation about the circumstances in which multi-spectral image fusion in general and specific fusion methods in particular would be superior to using the original image sources can be further addressed.

  19. Act Your (Old) Age: Prescriptive, Ageist Biases Over Succession, Consumption, and Identity

    PubMed Central

    North, Michael S.; Fiske, Susan T.

    2015-01-01

    Perspectives on ageism have focused on descriptive stereotypes concerning what older people allegedly are. By contrast, we introduce prescriptive stereotypes that attempt to control how older people should be: encouraging active Succession of envied resources, preventing passive Consumption of shared resources, and avoidance of symbolic, ingroup identity resources. Six studies test these domains, utilizing vignette experiments and simulated behavioral interactions. Across studies, younger (compared with middle-aged and older) raters most resented elder violators of prescriptive stereotypes. Moreover, these younger participants were most polarized toward older targets (compared with middle-aged and younger analogues) – rewarding elders most for prescription adherences and punishing them most for violations. Taken together, these findings offer a novel approach to ageist prescriptions, which disproportionately target older people, are most endorsed by younger people, and suggest how elders shift from receiving the default prejudice of pity to either prescriptive resentment or reward. PMID:23471317

  20. Spatial working memory for locations specified by vision and audition: testing the amodality hypothesis.

    PubMed

    Loomis, Jack M; Klatzky, Roberta L; McHugh, Brendan; Giudice, Nicholas A

    2012-08-01

    Spatial working memory can maintain representations from vision, hearing, and touch, representations referred to here as spatial images. The present experiment addressed whether spatial images from vision and hearing that are simultaneously present within working memory retain modality-specific tags or are amodal. Observers were presented with short sequences of targets varying in angular direction, with the targets in a given sequence being all auditory, all visual, or a sequential mixture of the two. On two thirds of the trials, one of the locations was repeated, and observers had to respond as quickly as possible when detecting this repetition. Ancillary detection and localization tasks confirmed that the visual and auditory targets were perceptually comparable. Response latencies in the working memory task showed small but reliable costs in performance on trials involving a sequential mixture of auditory and visual targets, as compared with trials of pure vision or pure audition. These deficits were statistically reliable only for trials on which the modalities of the matching location switched from the penultimate to the final target in the sequence, indicating a switching cost. The switching cost for the pair in immediate succession means that the spatial images representing the target locations retain features of the visual or auditory representations from which they were derived. However, there was no reliable evidence of a performance cost for mixed modalities in the matching pair when the second of the two did not immediately follow the first, suggesting that more enduring spatial images in working memory may be amodal.

  1. Control of Aedes albopictus with attractive toxic sugar baits (ATSB) and potential impact on non-target organisms in St. Augustine, Florida

    PubMed Central

    Revay, Edita E.; Müller, Gunter C.; Qualls, Whitney A.; Kline, Daniel; Naranjo, Diana P.; Arheart, Kristopher L.; Kravchenko, Vasiliy D.; Yfremova, Zoya; Hausmann, Axel; Beier, John C.; Schlein, Yosef; Xue, Rui-De

    2013-01-01

    The purpose of this study was to test the efficacy of bait stations and foliar applications containing attractive toxic sugar baits (ATSB) and eugenol to control Aedes albopictus. At the same time the potential impact of these control methods was evaluated on non-target organisms. The study was conducted at five tire sites in St. Augustine, Florida. Aedes albopictus populations were significantly reduced with ATSB-eugenol applications applied directly to non-flowering vegetation and as bait stations compared with non-attractive sugar baits and control. The application of ATSB made to non-flowering vegetation resulted in more significant reductions of mosquito populations compared to the application of ATSB presented in a bait station. Over 5.5% of the non-targets were stained in the flowering vegetation application site. However, when the attractive sugar bait application was made to non-flowering vegetation or presented in bait stations the impact on non-target insects was very low for all non-target orders as only 0.6% of the individual insects were stained with the dye from the sugar solutions, respectively. There were no significant differences between the staining of mosquitoes collected in flowering vegetation (206/1000) or non-flowering vegetation (242/1000) sites during the non-target evaluation. Our field studies support the use of eugenol as an active ingredient for controlling the dengue vector Ae. albopictus when used as an ATSB toxin and demonstrates potential use in sub-tropical and tropical environments for dengue control. PMID:24122115

  2. Improved cardiac management with a disease management program incorporating comprehensive lipid profiling.

    PubMed

    McAna, John F; Goldfarb, Neil I; Couto, Joseph; Henry, Michelle A; Piefer, Gary; Rapier, George M

    2012-02-01

    The objective of this study was to evaluate the improved effectiveness of a disease management treatment protocol incorporating comprehensive lipid profiling and targeted lipid care based on lipid profile findings in patients with ischemic heart disease (IHD) or congestive heart failure (CHF) enrolled in a managed care plan. This retrospective cohort study, conducted over a 2-year period, compared outcomes between patients with a standard lipid profile to those evaluated with a comprehensive lipid profile. All adult members of the WellMed Medical Management, Inc. managed care health plan diagnosed with IHD or CHF, and continuously enrolled between July 1, 2006 and June 30, 2008, were included in the study. Cases were defined as those who had at least 1 comprehensive lipid test (the VAP [vertical auto profile] ultracentrifuge test) during this period (n=1767); they were compared to those who had no lipid testing or traditional standard lipid testing only (controls, n=289). Univariate statistics were analyzed to describe the groups, and bivariate t tests or chi-squares examined differences between the 2 cohorts. Multivariate regression analyses were performed to control for potential confounders. The results show that the case group had lower total costs ($4852.62 vs. $7413.18; P=0.0255), fewer inpatient stays (13.1% vs. 18.3% of controls; P=0.0175) and emergency department visits (11.9% vs. 15.6% of controls; P=0.0832). Prescription use and frequency of lipid measurement suggested improved control resulting from a targeted approach to managing specific dyslipidemias. A treatment protocol incorporating a comprehensive lipid profile appears to improve care and reduce utilization and costs in a disease management program for cardiac patients.

  3. A rapid immunochromatography test based on Hcp1 is a potential point-of-care test for serological diagnosis of melioidosis.

    PubMed

    Phokrai, Phornpun; Karoonboonyanan, Wisansanee; Thanapattarapairoj, Nida; Promkong, Chidchanok; Dulsuk, Adul; Koosakulnirand, Sirikamon; Canovali, Sasha; Indrawattana, Nitaya; Jutrakul, Yaowaruk; Wuthiekanun, Vanaporn; Limmathurotsakul, Direk; Brett, Paul J; Burtnick, Mary N; Lertmemongkolchai, Ganjana; Chantratita, Narisara

    2018-05-30

    Melioidosis is a fatal infectious disease caused by the environmental bacterium Burkholderia pseudomallei It is highly endemic in Asia and northern Australia but neglected in many other tropical countries. Melioidosis patients have a wide range of clinical manifestations and definitive diagnosis requires bacterial culture which can be time-consuming. A reliable rapid serological tool is greatly needed for disease surveillance and diagnosis. We previously demonstrated by ELISA that a hemolysin-coregulated protein (Hcp1) is a promising target for serodiagnosis of melioidosis. In this study, we have developed a rapid immunochromatography test (ICT) using Hcp1 as the target antigen (Hcp1-ICT). We evaluated this test for specific antibody detection using serum samples obtained from 4 groups of human subjects including : ( i ) 487 culture-confirmed melioidosis patients from four hospitals in northeast Thailand; ( ii ) 202 healthy donors from northeast Thailand; ( iii ) 90 U.S. healthy donors and ( iv ) 207 patients infected with other organisms. Compared to culture results as a gold standard, the sensitivity of ICT for all hospitals was 88.3 %. The specificities for Thai donors and U.S. donors were 86.1 % and 100 % , respectively and for other infections was 91.8 %. The results of the Hcp1-ICT demonstrated 92.4 % agreement with the Hcp1-ELISA with kappa value of 0.829 and is much improved when compared with the current serological method, indirect hemagglutination assay ( IHA ) ( 69.5 % sensitivity and 67.6 % specificity for Thais ). The Hcp1-ICT represents a potential point-of-care ( POC ) test and may be used to replace the IHA for screening of melioidosis in hospitals as well as resource-limited areas. Copyright © 2018 Phokrai et al.

  4. Allegany Ballistics Lab: sensor test target system

    NASA Astrophysics Data System (ADS)

    Eaton, Deran S.

    2011-06-01

    Leveraging the Naval Surface Warfare Center, Indian Head Division's historical experience in weapon simulation, Naval Sea Systems Command commissioned development of a remote-controlled, digitally programmable Sensor Test Target as part of a modern, outdoor hardware-in-the-loop test system for ordnance-related guidance, navigation and control systems. The overall Target system design invokes a sciences-based, "design of automated experiments" approach meant to close the logistical distance between sensor engineering and developmental T&E in outdoor conditions over useful real world distances. This enables operating modes that employ broad spectrum electromagnetic energy in many a desired combination, variably generated using a Jet Engine Simulator, a multispectral infrared emitter array, optically enhanced incandescent Flare Simulators, Emitter/Detector mounts, and an RF corner reflector kit. As assembled, the recently tested Sensor Test Target prototype being presented can capably provide a full array of useful RF and infrared target source simulations for RDT&E use with developmental and existing sensors. Certain Target technologies are patent pending, with potential spinoffs in aviation, metallurgy and biofuels processing, while others are variations on well-established technology. The Sensor Test Target System is planned for extended installation at Allegany Ballistics Laboratory (Rocket Center, WV).

  5. Reversal of Vascular Calcification and Aneurysms in a Rat Model Using Dual Targeted Therapy with EDTA- and PGG-Loaded Nanoparticles

    PubMed Central

    Nosoudi, Nasim; Chowdhury, Aniqa; Siclari, Steven; Karamched, Saketh; Parasaram, Vaideesh; Parrish, Joe; Gerard, Patrick; Vyavahare, Narendra

    2016-01-01

    Degeneration of elastic lamina and vascular calcification are common features of vascular pathology such as aortic aneurysms. We tested whether dual therapy with targeted nanoparticles (NPs) can remove mineral deposits (by delivery of a chelating agent, ethylene diamine tetraacetic acid (EDTA)) and restore elastic lamina (by delivery of a polyphenol, pentagalloyl glucose (PGG)) to reverse moderate aneurysm development. EDTA followed by PGG NP delivery led to reduction in macrophage recruitment, matrix metalloproteinase (MMP) activity, elastin degradation and calcification in the aorta as compared to delivery of control blank NPs. Such dual therapy restored vascular elastic lamina and improved vascular function as observed by improvement in circumferential strain. Therefore, dual targeted therapy may be an attractive option to remove mineral deposits and restore healthy arterial structures in moderately developed aneurysms. PMID:27698934

  6. Speeded Reaching Movements around Invisible Obstacles

    PubMed Central

    Hudson, Todd E.; Wolfe, Uta; Maloney, Laurence T.

    2012-01-01

    We analyze the problem of obstacle avoidance from a Bayesian decision-theoretic perspective using an experimental task in which reaches around a virtual obstacle were made toward targets on an upright monitor. Subjects received monetary rewards for touching the target and incurred losses for accidentally touching the intervening obstacle. The locations of target-obstacle pairs within the workspace were varied from trial to trial. We compared human performance to that of a Bayesian ideal movement planner (who chooses motor strategies maximizing expected gain) using the Dominance Test employed in Hudson et al. (2007). The ideal movement planner suffers from the same sources of noise as the human, but selects movement plans that maximize expected gain in the presence of that noise. We find good agreement between the predictions of the model and actual performance in most but not all experimental conditions. PMID:23028276

  7. Building face composites can harm lineup identification performance.

    PubMed

    Wells, Gary L; Charman, Steve D; Olson, Elizabeth A

    2005-09-01

    Face composite programs permit eyewitnesses to build likenesses of target faces by selecting facial features and combining them into an intact face. Research has shown that these composites are generally poor likenesses of the target face. Two experiments tested the proposition that this composite-building process could harm the builder's memory for the face. In Experiment 1 (n = 150), the authors used 50 different faces and found that the building of a composite reduced the chances that the person could later identify the original face from a lineup when compared with no composite control conditions or with yoked composite-exposure control conditions. In Experiment 2 (n = 200), the authors found that this effect generalized to a simulated-crime video, but mistaken identifications from target-absent lineups were not inflated by composite building. Copyright 2005 APA, all rights reserved.

  8. Cardiovascular Genetic Risk Testing for Targeting Statin Therapy in the Primary Prevention of Atherosclerotic Cardiovascular Disease: A Cost-Effectiveness Analysis.

    PubMed

    Jarmul, Jamie; Pletcher, Mark J; Hassmiller Lich, Kristen; Wheeler, Stephanie B; Weinberger, Morris; Avery, Christy L; Jonas, Daniel E; Earnshaw, Stephanie; Pignone, Michael

    2018-04-01

    It is unclear whether testing for novel risk factors, such as a cardiovascular genetic risk score (cGRS), improves clinical decision making or health outcomes when used for targeting statin initiation in the primary prevention of atherosclerotic cardiovascular disease (ASCVD). Our objective was to estimate the cost-effectiveness of cGRS testing to inform clinical decision making about statin initiation in individuals with low-to-intermediate (2.5%-7.5%) 10-year predicted risk of ASCVD. We evaluated the cost-effectiveness of testing for a 27-single-nucleotide polymorphism cGRS comparing 4 test/treat strategies: treat all, treat none, test/treat if cGRS is high, and test/treat if cGRS is intermediate or high. We tested a set of clinical scenarios of men and women, aged 45 to 65 years, with 10-year ASCVD risks between 2.5% and 7.5%. Our primary outcome measure was cost per quality-adjusted life-year gained. Under base case assumptions for statin disutility and cost, the preferred strategy is to treat all patients with ASCVD risk >2.5% without cGRS testing. For certain clinical scenarios, such as a 57-year-old man with a 10-year ASCVD risk of 7.5%, cGRS testing can be cost-effective under a limited set of assumptions; for example, when statins cost $15 per month and statin disutility is 0.013 (ie, willing to trade 3 months of life in perfect health to avoid 20 years of statin therapy), the preferred strategy (using a willingness-to-pay threshold of $50 000 per quality-adjusted life-year gained) is to test and treat if cGRS is intermediate or high. Overall, the results were not sensitive to assumptions about statin efficacy and harms. Testing for a 27-single-nucleotide polymorphism cGRS is generally not a cost-effective approach for targeting statin therapy in the primary prevention of ASCVD for low- to intermediate-risk patients. © 2018 American Heart Association, Inc.

  9. Butyl rubber O-ring seals: Revision of test procedures for stockpile materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Domeier, L.A.; Wagter, K.R.

    1996-12-01

    Extensive testing showed little correlation between test slab and O-ring performance. New procedures, comparable to those used with the traditional test slabs, were defined for hardness, compression set, and tensile property testing on sacrificial O-ring specimens. Changes in target performance values were made as needed and were, in one case, tightened to reflect the O-ring performance data. An additional study was carried out on O-ring and slab performance vs cure cycle and showed little sensitivity of material performance to large changes in curing time. Aging and spectra of certain materials indicated that two sets of test slabs from current vendormore » were accidently made from EPDM rather than butyl rubber. Random testing found no O-rings made from EPDM. As a result, and additional spectroscope test will be added to the product acceptance procedures to verify the type of rubber compound used.« less

  10. Oligodeoxynucleotide Probes for Detecting Intact Cells

    NASA Technical Reports Server (NTRS)

    Rosson, Reinhardt A.; Maurina-Brunker, Julie; Langley, Kim; Pynnonen, Christine M.

    2004-01-01

    A rapid, sensitive test using chemiluminescent oligodeoxynucleotide probes has been developed for detecting, identifying, and enumerating intact cells. The test is intended especially for use in detecting and enumerating bacteria and yeasts in potable water. As in related tests that have been developed recently for similar purposes, the oligodeoxynucleotide probes used in this test are typically targeted at either singlecopy deoxyribonucleic acid (DNA) genes (such as virulence genes) or the multiple copies (10,000 to 50,000 copies per cell) of 16S ribosomal ribonucleic acids (rRNAs). Some of those tests involve radioisotope or fluorescent labeling of the probes for reporting hybridization of probes to target nucleic acids. Others of those tests involve labeling with enzymes plus the use of chemiluminescent or chromogenic substrates to report hybridization via color or the emission of light, respectively. The present test is of the last-mentioned type. The chemiluminescence in the present test can be detected easily with relatively simple instrumentation. In developing the present test, the hybridization approach was chosen because hybridization techniques are very specific. Hybridization detects stable, inheritable genetic targets within microorganisms. These targets are not dependent on products of gene expression that can vary with growth conditions or physiological states of organisms in test samples. Therefore, unique probes can be designed to detect and identify specific genera or species of bacteria or yeast (in terms of rRNA target sequences) or can be designed to detect and identify virulence genes (genomic target sequences). Because of the inherent specificity of this system, there are few problems of cross-reactivity. Hybridization tests are rapid, but hybridization tests now available commercially lack sensitivity; typically, between 10(exp 6) and 10(exp 7) cells of the target organism are needed to ensure a reliable test. Consequently, the numbers of target bacteria in samples are usually amplified by overnight pre-enrichment growth. These tests are usually performed in laboratories by skilled technicians. The present test was designed to overcome the shortcomings of the commercial hybridization tests. The figure summarizes the major steps of the test. It is important to emphasize that the hybridization process used in this test differs from that of other hybridization tests in that it does not extract target nucleic acids. This process is based on intact-cell hybridization (so-called in situ hybridization ), wherein the intact cells act as immobilizing agents. The cells are identified and enumerated by measuring the chemiluminescence emitted from alkaline phosphatase-probe (AP-probe) hybridization; the chemiluminescence is detected or measured by use of photographic film or a luminometer, respectively.

  11. Effects of practice on tip-of-the-tongue states.

    PubMed

    Smith, S M; Balfour, S P; Brown, J M

    1994-03-01

    Tip-of-the-tongue (TOT) states were examined in relation to acquisition manipulations, using named imaginary animals (TOTimals) as targets. High levels of TOT states were found in three experiments. In the first experiment an increase in the duration of initial exposure to target material improved recall and recognition, and reduced the number of unrecalled items not in TOT states (NTOTs), but did not affect TOT levels. In Experiment 2 practice at writing target names, as compared with only reading them, improved recall performance and decreased TOT levels, but did not reduce NTOTs. Experiment 3 replicated the finding that writing during practice reduced TOT states, but did not reduce NTOTs, and also found that more frequent practice trials increased recall without affecting TOT levels. The results suggest that practice writing target names prevents TOT states by strengthening otherwise deficient phonological connections in memory, a deficiency that can cause TOT states when visual-to-lexical connections give only partial access to a target in memory. The results also demonstrate the usefulness of the TOTimal technique for testing effects of acquisition variables on TOT experiences.

  12. Effects of Ethnic Targeting on the Perceived Effectiveness of Cancer Prevention Messages among Latinas and Non-Hispanic White Women

    PubMed Central

    Ramírez, A. Susana

    2017-01-01

    Efforts to target Latinos generally mean Spanish-language messages, yet 75% of U.S. Latinos are bilingual or English-dominant. Acculturation (adapting mainstream traits) is associated with increased lifestyle-related risk behaviors. Latinos maintain cultural traits and ethnic identification even as they appear to acculturate (e.g., through language). This raises questions about how to communicate health information to more-acculturated Latinos who are not reached by traditional Spanish outreach, yet may not identify with general-market messages. This study tested the relative efficacy of English-language messages targeted to Latinas, compared with general-market messages, among highly-acculturated Latinas and Non-Latina White women. In this pair of online experiments, Latinas (N=715) and Non-Latina White women (N=704) rated the perceived effectiveness of general-market versus Latina-targeted Pap smear and mammogram public service announcements. In one of two experiments ethnically-targeted messages were rated relatively more effective for the intended audience and equally effective for the general audience. Implications for how campaigns reach U.S. Latinos across the acculturation spectrum are discussed. PMID:23829690

  13. A Cost-Effectiveness Analysis of a Home-Based HIV Counselling and Testing Intervention versus the Standard (Facility Based) HIV Testing Strategy in Rural South Africa

    PubMed Central

    Tabana, Hanani; Nkonki, Lungiswa; Hongoro, Charles; Doherty, Tanya; Ekström, Anna Mia; Naik, Reshma; Zembe-Mkabile, Wanga; Jackson, Debra; Thorson, Anna

    2015-01-01

    Introduction There is growing evidence concerning the acceptability and feasibility of home-based HIV testing. However, less is known about the cost-effectiveness of the approach yet it is a critical component to guide decisions about scaling up access to HIV testing. This study examined the cost-effectiveness of a home-based HIV testing intervention in rural South Africa. Methods Two alternatives: clinic and home-based HIV counselling and testing were compared. Costs were analysed from a provider’s perspective for the period of January to December 2010. The outcome, HIV counselling and testing (HCT) uptake was obtained from the Good Start home-based HIV counselling and testing (HBHCT) cluster randomised control trial undertaken in KwaZulu-Natal province. Cost-effectiveness was estimated for a target population of 22,099 versus 23,864 people for intervention and control communities respectively. Average costs were calculated as the cost per client tested, while cost-effectiveness was calculated as the cost per additional client tested through HBHCT. Results Based on effectiveness of 37% in the intervention (HBHCT) arm compared to 16% in control arm, home based testing costs US$29 compared to US$38 per person for clinic HCT. The incremental cost effectiveness per client tested using HBHCT was $19. Conclusions HBHCT was less costly and more effective. Home-based HCT could present a cost-effective alternative for rural ‘hard to reach’ populations depending on affordability by the health system, and should be considered as part of community outreach programs. PMID:26275059

  14. A Cost-Effectiveness Analysis of a Home-Based HIV Counselling and Testing Intervention versus the Standard (Facility Based) HIV Testing Strategy in Rural South Africa.

    PubMed

    Tabana, Hanani; Nkonki, Lungiswa; Hongoro, Charles; Doherty, Tanya; Ekström, Anna Mia; Naik, Reshma; Zembe-Mkabile, Wanga; Jackson, Debra; Thorson, Anna

    2015-01-01

    There is growing evidence concerning the acceptability and feasibility of home-based HIV testing. However, less is known about the cost-effectiveness of the approach yet it is a critical component to guide decisions about scaling up access to HIV testing. This study examined the cost-effectiveness of a home-based HIV testing intervention in rural South Africa. Two alternatives: clinic and home-based HIV counselling and testing were compared. Costs were analysed from a provider's perspective for the period of January to December 2010. The outcome, HIV counselling and testing (HCT) uptake was obtained from the Good Start home-based HIV counselling and testing (HBHCT) cluster randomised control trial undertaken in KwaZulu-Natal province. Cost-effectiveness was estimated for a target population of 22,099 versus 23,864 people for intervention and control communities respectively. Average costs were calculated as the cost per client tested, while cost-effectiveness was calculated as the cost per additional client tested through HBHCT. Based on effectiveness of 37% in the intervention (HBHCT) arm compared to 16% in control arm, home based testing costs US$29 compared to US$38 per person for clinic HCT. The incremental cost effectiveness per client tested using HBHCT was $19. HBHCT was less costly and more effective. Home-based HCT could present a cost-effective alternative for rural 'hard to reach' populations depending on affordability by the health system, and should be considered as part of community outreach programs.

  15. Comparative Effectiveness of Targeted Prostate Biopsy Using Magnetic Resonance Imaging Ultrasound Fusion Software and Visual Targeting: a Prospective Study.

    PubMed

    Lee, Daniel J; Recabal, Pedro; Sjoberg, Daniel D; Thong, Alan; Lee, Justin K; Eastham, James A; Scardino, Peter T; Vargas, Hebert Alberto; Coleman, Jonathan; Ehdaie, Behfar

    2016-09-01

    We compared the diagnostic outcomes of magnetic resonance-ultrasound fusion and visually targeted biopsy for targeting regions of interest on prostate multiparametric magnetic resonance imaging. Patients presenting for prostate biopsy with regions of interest on multiparametric magnetic resonance imaging underwent magnetic resonance imaging targeted biopsy. For each region of interest 2 visually targeted cores were obtained, followed by 2 cores using a magnetic resonance-ultrasound fusion device. Our primary end point was the difference in the detection of high grade (Gleason 7 or greater) and any grade cancer between visually targeted and magnetic resonance-ultrasound fusion, investigated using McNemar's method. Secondary end points were the difference in detection rate by biopsy location using a logistic regression model and the difference in median cancer length using the Wilcoxon signed rank test. We identified 396 regions of interest in 286 men. The difference in the detection of high grade cancer between magnetic resonance-ultrasound fusion biopsy and visually targeted biopsy was -1.4% (95% CI -6.4 to 3.6, p=0.6) and for any grade cancer the difference was 3.5% (95% CI -1.9 to 8.9, p=0.2). Median cancer length detected by magnetic resonance-ultrasound fusion and visually targeted biopsy was 5.5 vs 5.8 mm, respectively (p=0.8). Magnetic resonance-ultrasound fusion biopsy detected 15% more cancers in the transition zone (p=0.046) and visually targeted biopsy detected 11% more high grade cancer at the prostate base (p=0.005). Only 52% of all high grade cancers were detected by both techniques. We found no evidence of a significant difference in the detection of high grade or any grade cancer between visually targeted and magnetic resonance-ultrasound fusion biopsy. However, the performance of each technique varied in specific biopsy locations and the outcomes of both techniques were complementary. Combining visually targeted biopsy and magnetic resonance-ultrasound fusion biopsy may optimize the detection of prostate cancer. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  16. Short-term toxicity of 1-methylnaphthalene to Americamysis bahia and 5 deep-sea crustaceans.

    PubMed

    Knap, Anthony; Turner, Nicholas R; Bera, Gopal; Renegar, D Abigail; Frank, Tamara; Sericano, Jose; Riegl, Bernhard M

    2017-12-01

    There are few studies that have evaluated hydrocarbon toxicity to vertically migrating deep-sea micronekton. Crustaceans were collected alive using a 9-m 2 Tucker trawl with a thermally insulated cod end and returned to the laboratory in 10 °C seawater. Toxicity of the polycyclic aromatic hydrocarbon 1-methylnaphthalene to Americamysis bahia, Janicella spinacauda, Systellaspis debilis, Sergestes sp., Sergia sp., and a euphausiid species was assessed in a constant exposure toxicity test utilizing a novel passive dosing toxicity testing protocol. The endpoint of the median lethal concentration tests was mortality, and the results revealed high sensitivity of the deep-sea micronekton compared with other species for which these data are available. Threshold concentrations were also used to calculate critical target lipid body burdens using the target lipid model. Environ Toxicol Chem 2017;36:3415-3423. © 2017 The Authors. Environmental Toxicology and Chemistry published by Wiley Periodicals, Inc. on behalf of SETAC. © 2017 The Authors. Environmental Toxicology and Chemistry published by Wiley Periodicals, Inc. on behalf of SETAC.

  17. Effects of comprehensive geriatric intervention on physical performance among people aged 75 years and over.

    PubMed

    Lihavainen, Katri; Sipilä, Sarianna; Rantanen, Taina; Seppänen, Jarmo; Lavikainen, Piia; Sulkava, Raimo; Hartikainen, Sirpa

    2012-08-01

    We studied the effects of comprehensive geriatric assessment and multifactorial intervention on physical performance among older people. In a 3-year geriatric development project with an experimental design, 668 participants aged 75-98 were assigned to intervention (n=348) or control (n=320) groups. The intervention group received comprehensive geriatric assessment with an individually targeted intervention for 2 years. The outcome measures - performance in the Timed Up-and-Go (TUG), 10-meter walking and Berg Balance Scale tests - were gathered annually during the intervention and the 1-year follow-up after it. With linear mixed models, over the 2-year intervention period, the intervention group was found to be improved in the balance (p<0.001) and walking speed (p<0.001) tests, and maintained performance in the TUG test (p<0.001), compared with the control group. The results remained significant 1 year post-intervention. Comprehensive geriatric assessment and individually targeted multifactorial intervention had positive effects on physical performance, potentially helping to maintain mobility and prevent disability in old age.

  18. Environmental cue saliency influences the vividness of a remote spatial memory in rats.

    PubMed

    Lopez, Joëlle; de Vasconcelos, Anne Pereira; Cassel, Jean-Christophe

    2008-07-01

    The Morris water maze is frequently used to evaluate the acquisition and retrieval of spatial memories. Few experiments, however, have investigated the effects of environmental cue saliency on the strength or persistence of such memories after a short vs. long post-acquisition interval. Using a Morris water maze, we therefore tested in rats the effect of the saliency of distal cues on the vividness of a recent (5 days) vs. remote (25 days) memory. Rats trained in a cue-enriched vs. a cue-impoverished context showed a better overall level of performance during acquisition. Furthermore, the probe trials revealed that the rats trained and tested in the cue-impoverished context (1) spent less time in the target quadrant at the 25-day delay, and (2) swam shorter distances in the target area, with fewer crossings at both 5- and 25-day delays, as compared to their counterparts trained and tested in the cue-enriched context. Thus, the memory trace formed in the cue-enriched context shows better resistance to time, suggesting an implication of cue saliency in the vividness of a spatial memory.

  19. Targeting as the basis for pre-test market of lithium-ion battery

    NASA Astrophysics Data System (ADS)

    Yuniaristanto, Zakaria, R.; Saputri, V. H. L.; Sutopo, W.; Kadir, E. A.

    2017-11-01

    This article discusses about market segmentation and targeting as a first step in pre-test market of a new technology. The benefits of targeting towards pre-test market are pre-test market can be conducted to focus on selected target markets so there is no bias during the pre-test market. In determining the target market then do some surveys to identify the state of market in the future, so that the marketing process is not misplaced. Lithium ion battery which is commercialized through start-up companies is the case study. This start-up companies must be able to respond the changes and bring in customers as well as maintain them so that companies can survive and evolve to achieve its objectives. The research aims to determine market segments and target market effectively. Marketing strategy (segmentation and targeting) is used to make questionnaire and cluster analysis in data processing. Respondents were selected by purposive sampling and have obtained data as many as 80 samples. As the results study, there are three segments for lithium ion battery with their own distinguished characteristics and there are two segments that can be used as the target market for the company.

  20. The accomplishments of lithium target and test facility validation activities in the IFMIF/EVEDA phase

    NASA Astrophysics Data System (ADS)

    Arbeiter, Frederik; Baluc, Nadine; Favuzza, Paolo; Gröschel, Friedrich; Heidinger, Roland; Ibarra, Angel; Knaster, Juan; Kanemura, Takuji; Kondo, Hiroo; Massaut, Vincent; Saverio Nitti, Francesco; Miccichè, Gioacchino; O'hira, Shigeru; Rapisarda, David; Sugimoto, Masayoshi; Wakai, Eiichi; Yokomine, Takehiko

    2018-01-01

    As part of the engineering validation and engineering design activities (EVEDA) phase for the international fusion materials irradiation facility IFMIF, major elements of a lithium target facility and the test facility were designed, prototyped and validated. For the lithium target facility, the EVEDA lithium test loop was built at JAEA and used to test the stability (waves and long term) of the lithium flow in the target, work out the startup procedures, and test lithium purification and analysis. It was confirmed by experiments in the Lifus 6 plant at ENEA that lithium corrosion on ferritic martensitic steels is acceptably low. Furthermore, complex remote handling procedures for the remote maintenance of the target in the test cell environment were successfully practiced. For the test facility, two variants of a high flux test module were prototyped and tested in helium loops, demonstrating their good capabilities of maintaining the material specimens at the desired temperature with a low temperature spread. Irradiation tests were performed for heated specimen capsules and irradiation instrumentation in the BR2 reactor at SCK-CEN. The small specimen test technique, essential for obtaining material test results with limited irradiation volume, was advanced by evaluating specimen shape and test technique influences.

  1. HIV testing and sexual risk reduction counseling in office-based buprenorphine/naloxone treatment.

    PubMed

    Edelman, E Jennifer; Moore, Brent A; Caffrey, Sarah; Sikkema, Kathleen J; Jones, Emlyn S; Schottenfeld, Richard S; Fiellin, David A; Fiellin, Lynn E

    2013-01-01

    We assessed the feasibility and preliminary efficacy of human immunodeficiency virus (HIV) testing with sexual risk reduction counseling for opioid-dependent patients initiating office-based buprenorphine/naloxone treatment. We conducted a 14-week randomized, controlled trial with 30 patients (original target of 114) assigned to receive buprenorphine/naloxone induction/stabilization and HIV testing with Brief Sexual Risk Management (BSRM) or Enhanced Sexual Risk Management (ESRM). We evaluated process measures and compared outcomes at baseline and during the 3-month follow-up. Similar proportions of patients receiving BSRM and ESRM underwent HIV testing (93% vs 80%; P = 0.28) and completed counseling sessions (80% vs 67%; P = 0.40). Brief Sexual Risk Management sessions were shorter than ESRM sessions (15.4 vs 23.4 minutes), with comparable manual adherence (P = 0.80). Outcomes did not vary by BSRM versus ESRM. Although the recruitment of opioid-dependent patients with sexual risk behaviors is challenging, HIV testing with sexual risk reduction counseling in office-based buprenorphine/naloxone treatment practice is feasible. Interventions to decrease sexual risk behaviors among a segment of this population are necessary.

  2. Estimation of post-test probabilities by residents: Bayesian reasoning versus heuristics?

    PubMed

    Hall, Stacey; Phang, Sen Han; Schaefer, Jeffrey P; Ghali, William; Wright, Bruce; McLaughlin, Kevin

    2014-08-01

    Although the process of diagnosing invariably begins with a heuristic, we encourage our learners to support their diagnoses by analytical cognitive processes, such as Bayesian reasoning, in an attempt to mitigate the effects of heuristics on diagnosing. There are, however, limited data on the use ± impact of Bayesian reasoning on the accuracy of disease probability estimates. In this study our objective was to explore whether Internal Medicine residents use a Bayesian process to estimate disease probabilities by comparing their disease probability estimates to literature-derived Bayesian post-test probabilities. We gave 35 Internal Medicine residents four clinical vignettes in the form of a referral letter and asked them to estimate the post-test probability of the target condition in each case. We then compared these to literature-derived probabilities. For each vignette the estimated probability was significantly different from the literature-derived probability. For the two cases with low literature-derived probability our participants significantly overestimated the probability of these target conditions being the correct diagnosis, whereas for the two cases with high literature-derived probability the estimated probability was significantly lower than the calculated value. Our results suggest that residents generate inaccurate post-test probability estimates. Possible explanations for this include ineffective application of Bayesian reasoning, attribute substitution whereby a complex cognitive task is replaced by an easier one (e.g., a heuristic), or systematic rater bias, such as central tendency bias. Further studies are needed to identify the reasons for inaccuracy of disease probability estimates and to explore ways of improving accuracy.

  3. Rickettsia prowazekii methionine aminopeptidase as a promising target for the development of antibacterial agents

    DOE PAGES

    Helgren, Travis R.; Chen, Congling; Wangtrakuldee, Phumvadee; ...

    2016-11-10

    Methionine aminopeptidase (MetAP) is a class of ubiquitous enzymes essential for the survival of numerous bacterial species. These enzymes are responsible for the cleavage of N-terminal formyl-methionine initiators from nascent proteins to initiate post-translational modifications that are often essential to proper protein function. Thus, inhibition of MetAP activity has been implicated as a novel antibacterial target. In this study, we tested this idea in the present study by targeting the MetAP enzyme in the obligate intracellular pathogen Rickettsia prowazekii. We first identified potent RpMetAP inhibitory species by employing an in vitro enzymatic activity assay. The molecular docking program AutoDock wasmore » then utilized to compare published crystal structures of inhibited MetAP species to docked poses of RpMetAP. Based on these in silico and in vitro screens, a subset of 17 compounds was tested for inhibition of R. prowazekii growth in a pulmonary vascular endothelial cell (EC) culture infection model system. All compounds were tested over concentration ranges that were determined to be non-toxic to the ECs and 8 of the 17 compounds displayed substantial inhibition of R. prowazekii growth. Lastly, these data highlight the therapeutic potential for inhibiting RpMetAP as a novel antimicrobial strategy and set the stage for future studies in pre-clinical animal models of infection.« less

  4. Rickettsia prowazekii methionine aminopeptidase as a promising target for the development of antibacterial agents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Helgren, Travis R.; Chen, Congling; Wangtrakuldee, Phumvadee

    Methionine aminopeptidase (MetAP) is a class of ubiquitous enzymes essential for the survival of numerous bacterial species. These enzymes are responsible for the cleavage of N-terminal formyl-methionine initiators from nascent proteins to initiate post-translational modifications that are often essential to proper protein function. Thus, inhibition of MetAP activity has been implicated as a novel antibacterial target. In this study, we tested this idea in the present study by targeting the MetAP enzyme in the obligate intracellular pathogen Rickettsia prowazekii. We first identified potent RpMetAP inhibitory species by employing an in vitro enzymatic activity assay. The molecular docking program AutoDock wasmore » then utilized to compare published crystal structures of inhibited MetAP species to docked poses of RpMetAP. Based on these in silico and in vitro screens, a subset of 17 compounds was tested for inhibition of R. prowazekii growth in a pulmonary vascular endothelial cell (EC) culture infection model system. All compounds were tested over concentration ranges that were determined to be non-toxic to the ECs and 8 of the 17 compounds displayed substantial inhibition of R. prowazekii growth. Lastly, these data highlight the therapeutic potential for inhibiting RpMetAP as a novel antimicrobial strategy and set the stage for future studies in pre-clinical animal models of infection.« less

  5. Fusion enhancement at near and sub-barrier energies in 19O + 12C

    DOE PAGES

    Singh, Varinderjit; Vadas, J.; Steinbach, T. K.; ...

    2016-12-12

    Measuring the fusion excitation function for an isotopic chain of projectile nuclei provides a stringent test of a microscopic description of fusion. We report the first measurement of the fusion excitation function at near-barrier energies for the 19O+ 12C system. The measured excitation function is compared with the fusion excitation function of 18O+ 12C. A significant enhancement in the fusion probability of 19O ions with a 12C target as compared to 18O ions is observed. As a result, the experimental cross-sections observed at near-barrier energies are compared with a state-of-the-art microscopic model.

  6. How does cognition evolve? Phylogenetic comparative psychology

    PubMed Central

    Matthews, Luke J.; Hare, Brian A.; Nunn, Charles L.; Anderson, Rindy C.; Aureli, Filippo; Brannon, Elizabeth M.; Call, Josep; Drea, Christine M.; Emery, Nathan J.; Haun, Daniel B. M.; Herrmann, Esther; Jacobs, Lucia F.; Platt, Michael L.; Rosati, Alexandra G.; Sandel, Aaron A.; Schroepfer, Kara K.; Seed, Amanda M.; Tan, Jingzhi; van Schaik, Carel P.; Wobber, Victoria

    2014-01-01

    Now more than ever animal studies have the potential to test hypotheses regarding how cognition evolves. Comparative psychologists have developed new techniques to probe the cognitive mechanisms underlying animal behavior, and they have become increasingly skillful at adapting methodologies to test multiple species. Meanwhile, evolutionary biologists have generated quantitative approaches to investigate the phylogenetic distribution and function of phenotypic traits, including cognition. In particular, phylogenetic methods can quantitatively (1) test whether specific cognitive abilities are correlated with life history (e.g., lifespan), morphology (e.g., brain size), or socio-ecological variables (e.g., social system), (2) measure how strongly phylogenetic relatedness predicts the distribution of cognitive skills across species, and (3) estimate the ancestral state of a given cognitive trait using measures of cognitive performance from extant species. Phylogenetic methods can also be used to guide the selection of species comparisons that offer the strongest tests of a priori predictions of cognitive evolutionary hypotheses (i.e., phylogenetic targeting). Here, we explain how an integration of comparative psychology and evolutionary biology will answer a host of questions regarding the phylogenetic distribution and history of cognitive traits, as well as the evolutionary processes that drove their evolution. PMID:21927850

  7. Column Selection for Biomedical Analysis Supported by Column Classification Based on Four Test Parameters

    PubMed Central

    Plenis, Alina; Rekowska, Natalia; Bączek, Tomasz

    2016-01-01

    This article focuses on correlating the column classification obtained from the method created at the Katholieke Universiteit Leuven (KUL), with the chromatographic resolution attained in biomedical separation. In the KUL system, each column is described with four parameters, which enables estimation of the FKUL value characterising similarity of those parameters to the selected reference stationary phase. Thus, a ranking list based on the FKUL value can be calculated for the chosen reference column, then correlated with the results of the column performance test. In this study, the column performance test was based on analysis of moclobemide and its two metabolites in human plasma by liquid chromatography (LC), using 18 columns. The comparative study was performed using traditional correlation of the FKUL values with the retention parameters of the analytes describing the column performance test. In order to deepen the comparative assessment of both data sets, factor analysis (FA) was also used. The obtained results indicated that the stationary phase classes, closely related according to the KUL method, yielded comparable separation for the target substances. Therefore, the column ranking system based on the FKUL-values could be considered supportive in the choice of the appropriate column for biomedical analysis. PMID:26805819

  8. Column Selection for Biomedical Analysis Supported by Column Classification Based on Four Test Parameters.

    PubMed

    Plenis, Alina; Rekowska, Natalia; Bączek, Tomasz

    2016-01-21

    This article focuses on correlating the column classification obtained from the method created at the Katholieke Universiteit Leuven (KUL), with the chromatographic resolution attained in biomedical separation. In the KUL system, each column is described with four parameters, which enables estimation of the FKUL value characterising similarity of those parameters to the selected reference stationary phase. Thus, a ranking list based on the FKUL value can be calculated for the chosen reference column, then correlated with the results of the column performance test. In this study, the column performance test was based on analysis of moclobemide and its two metabolites in human plasma by liquid chromatography (LC), using 18 columns. The comparative study was performed using traditional correlation of the FKUL values with the retention parameters of the analytes describing the column performance test. In order to deepen the comparative assessment of both data sets, factor analysis (FA) was also used. The obtained results indicated that the stationary phase classes, closely related according to the KUL method, yielded comparable separation for the target substances. Therefore, the column ranking system based on the FKUL-values could be considered supportive in the choice of the appropriate column for biomedical analysis.

  9. How does cognition evolve? Phylogenetic comparative psychology.

    PubMed

    MacLean, Evan L; Matthews, Luke J; Hare, Brian A; Nunn, Charles L; Anderson, Rindy C; Aureli, Filippo; Brannon, Elizabeth M; Call, Josep; Drea, Christine M; Emery, Nathan J; Haun, Daniel B M; Herrmann, Esther; Jacobs, Lucia F; Platt, Michael L; Rosati, Alexandra G; Sandel, Aaron A; Schroepfer, Kara K; Seed, Amanda M; Tan, Jingzhi; van Schaik, Carel P; Wobber, Victoria

    2012-03-01

    Now more than ever animal studies have the potential to test hypotheses regarding how cognition evolves. Comparative psychologists have developed new techniques to probe the cognitive mechanisms underlying animal behavior, and they have become increasingly skillful at adapting methodologies to test multiple species. Meanwhile, evolutionary biologists have generated quantitative approaches to investigate the phylogenetic distribution and function of phenotypic traits, including cognition. In particular, phylogenetic methods can quantitatively (1) test whether specific cognitive abilities are correlated with life history (e.g., lifespan), morphology (e.g., brain size), or socio-ecological variables (e.g., social system), (2) measure how strongly phylogenetic relatedness predicts the distribution of cognitive skills across species, and (3) estimate the ancestral state of a given cognitive trait using measures of cognitive performance from extant species. Phylogenetic methods can also be used to guide the selection of species comparisons that offer the strongest tests of a priori predictions of cognitive evolutionary hypotheses (i.e., phylogenetic targeting). Here, we explain how an integration of comparative psychology and evolutionary biology will answer a host of questions regarding the phylogenetic distribution and history of cognitive traits, as well as the evolutionary processes that drove their evolution.

  10. Comparing pseudo-absences generation techniques in Boosted Regression Trees models for conservation purposes: A case study on amphibians in a protected area.

    PubMed

    Cerasoli, Francesco; Iannella, Mattia; D'Alessandro, Paola; Biondi, Maurizio

    2017-01-01

    Boosted Regression Trees (BRT) is one of the modelling techniques most recently applied to biodiversity conservation and it can be implemented with presence-only data through the generation of artificial absences (pseudo-absences). In this paper, three pseudo-absences generation techniques are compared, namely the generation of pseudo-absences within target-group background (TGB), testing both the weighted (WTGB) and unweighted (UTGB) scheme, and the generation at random (RDM), evaluating their performance and applicability in distribution modelling and species conservation. The choice of the target group fell on amphibians, because of their rapid decline worldwide and the frequent lack of guidelines for conservation strategies and regional-scale planning, which instead could be provided through an appropriate implementation of SDMs. Bufo bufo, Salamandrina perspicillata and Triturus carnifex were considered as target species, in order to perform our analysis with species having different ecological and distributional characteristics. The study area is the "Gran Sasso-Monti della Laga" National Park, which hosts 15 Natura 2000 sites and represents one of the most important biodiversity hotspots in Europe. Our results show that the model calibration ameliorates when using the target-group based pseudo-absences compared to the random ones, especially when applying the WTGB. Contrarily, model discrimination did not significantly vary in a consistent way among the three approaches with respect to the tree target species. Both WTGB and RDM clearly isolate the highly contributing variables, supplying many relevant indications for species conservation actions. Moreover, the assessment of pairwise variable interactions and their three-dimensional visualization further increase the amount of useful information for protected areas' managers. Finally, we suggest the use of RDM as an admissible alternative when it is not possible to individuate a suitable set of species as a representative target-group from which the pseudo-absences can be generated.

  11. 'Putting your foot in it'! A window into clumsy behaviour.

    PubMed

    Sigmundsson, H; Whiting, H T; Ingvaldsen, R P

    1999-07-01

    Intra-modal matching by 7-year-old children diagnosed as having hand-eye co-ordination problems (HECP) and a control group of children without such problems was tested using a target location and matching task. The 'foot-hand' task required the children to locate a target pin with the 'big-toe' (felt target) and match the located target position with the hand, without vision. There were four conditions: location via right foot-matching the located target with the right hand (RfRh) and left hand (RfLh) and location via left foot-matching the located target with the left hand (LfLh) and right hand (LfRh). Both groups demonstrated better performance in the intra- as compared to the inter-hemispheric conditions, suggesting that the corpus callosum is not yet fully mature at this age. The HECP children showed inferior performance to the control children in three of the four conditions, the conditions where the right hemisphere was involved and/or information had to be transported across the corpus callosum (RfLh; LfLh; LfRh). Two possible explanations of these findings are put forward and discussed: right hemisphere insufficiency with or without dysfunctional corpus callosum.

  12. Overlay accuracy with respect to device scaling

    NASA Astrophysics Data System (ADS)

    Leray, Philippe; Laidler, David; Cheng, Shaunee

    2012-03-01

    Overlay metrology performance is usually reported as repeatability, matching between tools or optics aberrations distorting the measurement (Tool induced shift or TIS). Over the last few years, improvement of these metrics by the tool suppliers has been impressive. But, what about accuracy? Using different target types, we have already reported small differences in the mean value as well as fingerprint [1]. These differences make the correctables questionable. Which target is correct and therefore which translation, scaling etc. values should be fed back to the scanner? In this paper we investigate the sources of these differences, using several approaches. First, we measure the response of different targets to offsets programmed in a test vehicle. Second, we check the response of the same overlay targets to overlay errors programmed into the scanner. We compare overlay target designs; what is the contribution of the size of the features that make up the target? We use different overlay measurement techniques; is DBO (Diffraction Based Overlay) more accurate than IBO (Image Based Overlay)? We measure overlay on several stacks; what is the stack contribution to inaccuracy? In conclusion, we offer an explanation for the observed differences and propose a solution to reduce them.

  13. Multishot Targeted PROPELLER Magnetic Resonance Imaging: Description of the Technique and Initial Applications

    PubMed Central

    Deng, Jie; Larson, Andrew C.

    2010-01-01

    Objectives To test the feasibility of combining inner-volume imaging (IVI) techniques with conventional multishot periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) techniques for targeted-PROPELLER magnetic resonance imaging. Materials and Methods Perpendicular section-selective gradients for spatially selective excitation and refocusing RF pulses were applied to limit the refocused field-of-view (FOV) along the phase-encoding direction for each rectangular blade image. We performed comparison studies in phantoms and normal volunteers by using targeted-PROPELLER methods for a wide range of imaging applications that commonly use turbo-spin-echo (TSE) approaches (brain, abdominal, vessel wall, cardiac). Results In these initial studies, we demonstrated the feasibility of using targeted-PROPELLER approaches to limit the imaging FOV thereby reducing the number of blades or permitting increased spatial resolution without commensurate increases in scan time. Both phantom and in vivo motion studies demonstrated the potential for more robust regional self-navigated motion correction compared with conventional full FOV PROPELLER methods. Conclusion We demonstrated that the reduced FOV targeted-PROPELLER technique offers the potential for reducing imaging time, increasing spatial resolution, and targeting specific areas for robust regional motion correction. PMID:19465860

  14. TarPmiR: a new approach for microRNA target site prediction.

    PubMed

    Ding, Jun; Li, Xiaoman; Hu, Haiyan

    2016-09-15

    The identification of microRNA (miRNA) target sites is fundamentally important for studying gene regulation. There are dozens of computational methods available for miRNA target site prediction. Despite their existence, we still cannot reliably identify miRNA target sites, partially due to our limited understanding of the characteristics of miRNA target sites. The recently published CLASH (crosslinking ligation and sequencing of hybrids) data provide an unprecedented opportunity to study the characteristics of miRNA target sites and improve miRNA target site prediction methods. Applying four different machine learning approaches to the CLASH data, we identified seven new features of miRNA target sites. Combining these new features with those commonly used by existing miRNA target prediction algorithms, we developed an approach called TarPmiR for miRNA target site prediction. Testing on two human and one mouse non-CLASH datasets, we showed that TarPmiR predicted more than 74.2% of true miRNA target sites in each dataset. Compared with three existing approaches, we demonstrated that TarPmiR is superior to these existing approaches in terms of better recall and better precision. The TarPmiR software is freely available at http://hulab.ucf.edu/research/projects/miRNA/TarPmiR/ CONTACTS: haihu@cs.ucf.edu or xiaoman@mail.ucf.edu Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press.

  15. Anti-mitotic agents: Are they emerging molecules for cancer treatment?

    PubMed

    Penna, Larissa Siqueira; Henriques, João Antonio Pêgas; Bonatto, Diego

    2017-05-01

    Mutations in cancer cells frequently result in cell cycle alterations that lead to unrestricted growth compared to normal cells. Considering this phenomenon, many drugs have been developed to inhibit different cell-cycle phases. Mitotic phase targeting disturbs mitosis in tumor cells, triggers the spindle assembly checkpoint and frequently results in cell death. The first anti-mitotics to enter clinical trials aimed to target tubulin. Although these drugs improved the treatment of certain cancers, and many anti-microtubule compounds are already approved for clinical use, severe adverse events such as neuropathies were observed. Since then, efforts have been focused on the development of drugs that also target kinases, motor proteins and multi-protein complexes involved in mitosis. In this review, we summarize the major proteins involved in the mitotic phase that can also be targeted for cancer treatment. Finally, we address the activity of anti-mitotic drugs tested in clinical trials in recent years. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Split green fluorescent protein as a modular binding partner for protein crystallization.

    PubMed

    Nguyen, Hau B; Hung, Li-Wei; Yeates, Todd O; Terwilliger, Thomas C; Waldo, Geoffrey S

    2013-12-01

    A modular strategy for protein crystallization using split green fluorescent protein (GFP) as a crystallization partner is demonstrated. Insertion of a hairpin containing GFP β-strands 10 and 11 into a surface loop of a target protein provides two chain crossings between the target and the reconstituted GFP compared with the single connection afforded by terminal GFP fusions. This strategy was tested by inserting this hairpin into a loop of another fluorescent protein, sfCherry. The crystal structure of the sfCherry-GFP(10-11) hairpin in complex with GFP(1-9) was determined at a resolution of 2.6 Å. Analysis of the complex shows that the reconstituted GFP is attached to the target protein (sfCherry) in a structurally ordered way. This work opens the way to rapidly creating crystallization variants by reconstituting a target protein bearing the GFP(10-11) hairpin with a variety of GFP(1-9) mutants engineered for favorable crystallization.

  17. Application and comparison of large-scale solution-based DNA capture-enrichment methods on ancient DNA

    PubMed Central

    Ávila-Arcos, María C.; Cappellini, Enrico; Romero-Navarro, J. Alberto; Wales, Nathan; Moreno-Mayar, J. Víctor; Rasmussen, Morten; Fordyce, Sarah L.; Montiel, Rafael; Vielle-Calzada, Jean-Philippe; Willerslev, Eske; Gilbert, M. Thomas P.

    2011-01-01

    The development of second-generation sequencing technologies has greatly benefitted the field of ancient DNA (aDNA). Its application can be further exploited by the use of targeted capture-enrichment methods to overcome restrictions posed by low endogenous and contaminating DNA in ancient samples. We tested the performance of Agilent's SureSelect and Mycroarray's MySelect in-solution capture systems on Illumina sequencing libraries built from ancient maize to identify key factors influencing aDNA capture experiments. High levels of clonality as well as the presence of multiple-copy sequences in the capture targets led to biases in the data regardless of the capture method. Neither method consistently outperformed the other in terms of average target enrichment, and no obvious difference was observed either when two tiling designs were compared. In addition to demonstrating the plausibility of capturing aDNA from ancient plant material, our results also enable us to provide useful recommendations for those planning targeted-sequencing on aDNA. PMID:22355593

  18. Proton Radiotherapy for Pediatric Bladder/Prostate Rhabdomyosarcoma: Clinical Outcomes and Dosimetry Compared to Intensity-Modulated Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cotter, Shane E.; Herrup, David A.; Friedmann, Alison

    Purpose: In this study, we report the clinical outcomes of 7 children with bladder/prostate rhabdomyosarcoma (RMS) treated with proton radiation and compare proton treatment plans with matched intensity-modulated radiation therapy (IMRT) plans, with an emphasis on dose savings to reproductive and skeletal structures. Methods and Materials: Follow-up consisted of scheduled clinic appointments at our institution or direct communication with the treating physicians for referred patients. Each proton radiotherapy plan used for treatment was directly compared to an IMRT plan generated for the study. Clinical target volumes and normal tissue volumes were held constant to facilitate dosimetric comparisons. Each plan wasmore » optimized for target coverage and normal tissue sparing. Results: Seven male patients were treated with proton radiotherapy for bladder/prostate RMS at the Massachusetts General Hospital between 2002 and 2008. Median age at treatment was 30 months (11-70 months). Median follow-up was 27 months (10-90 months). Four patients underwent a gross total resection prior to radiation, and all patients received concurrent chemotherapy. Radiation doses ranged from 36 cobalt Gray equivalent (CGE) to 50.4 CGE. Five of 7 patients were without evidence of disease and with intact bladders at study completion. Target volume dosimetry was equivalent between the two modalities for all 7 patients. Proton radiotherapy led to a significant decrease in mean organ dose to the bladder (25.1 CGE vs. 33.2 Gy; p = 0.03), testes (0.0 CGE vs. 0.6 Gy; p = 0.016), femoral heads (1.6 CGE vs. 10.6 Gy; p = 0.016), growth plates (21.7 CGE vs. 32.4 Gy; p = 0.016), and pelvic bones (8.8 CGE vs. 13.5 Gy; p = 0.016) compared to IMRT. Conclusions: This study provides evidence of significant dose savings to normal structures with proton radiotherapy compared to IMRT and is well tolerated in this patient population. The long-term impact of these reduced doses can be tested in future studies incorporating extended follow-up, objective outcome measures, and quality-of-life analyses.« less

  19. Toxicology Testing in Fatally Injured Workers: A Review of Five Years of Iowa FACE Cases

    PubMed Central

    Ramirez, Marizen; Bedford, Ronald; Sullivan, Ryan; Anthony, T. Renee; Kraemer, John; Faine, Brett; Peek-Asa, Corinne

    2013-01-01

    Toxicology testing of fatally injured workers is not routinely conducted. We completed a case-series study of 2005–2009 occupational fatalities captured by Iowa’s Fatality Assessment and Control Evaluation (FACE) Program. The goals of our research were to: (1) measure the proportion of FACE cases that undergo toxicology testing, and describe the factors associated with being tested, and (2) measure the rate of positive toxicology tests, the substances identified and the demographics and occupations of victims who tested positive. Case documents and toxicology laboratory reports were reviewed. There were 427 occupational deaths from 2005 to 2009. Only 69% underwent toxicology testing. Younger workers had greater odds of being tested. Among occupational groups, workers in farming, fishing and forestry had half the odds of being tested compared to other occupational groups. Of the 280 cases with toxicology tests completed, 22% (n = 61) were found to have positive toxicology testing. Commonly identified drug classes included cannabinoids and alcohols. Based on the small number of positive tests, older victims (65+ years) tested positive more frequently than younger workers. Management, business, science, arts, service and sales/office workers had proportionately more positive toxicology tests (almost 30%) compared with other workers (18–22%). These results identify an area in need of further research efforts and a potential target for injury prevention strategies. PMID:24240727

  20. Tumor targeting profiling of hyaluronan-coated lipid based-nanoparticles

    NASA Astrophysics Data System (ADS)

    Mizrahy, Shoshy; Goldsmith, Meir; Leviatan-Ben-Arye, Shani; Kisin-Finfer, Einat; Redy, Orit; Srinivasan, Srimeenakshi; Shabat, Doron; Godin, Biana; Peer, Dan

    2014-03-01

    Hyaluronan (HA), a naturally occurring high Mw (HMw) glycosaminoglycan, has been shown to play crucial roles in cell growth, embryonic development, healing processes, inflammation, and tumor development and progression. Low Mw (LMw, <10 kDa) HA has been reported to provoke inflammatory responses, such as induction of cytokines, chemokines, reactive nitrogen species and growth factors. Herein, we prepared and characterized two types of HA coated (LMw and HMw) lipid-based targeted and stabilized nanoparticles (tsNPs) and tested their binding to tumor cells expressing the HA receptor (CD44), systemic immunotoxicity, and biodistribution in tumor bearing mice. In vitro, the Mw of the surface anchored HA had a significant influence on the affinity towards CD44 on B16F10 murine melanoma cells. LMw HA-tsNPs exhibited weak binding, while binding of tsNPs coated with HMw HA was characterized by high binding. Both types of tsNPs had no measured effect on cytokine induction in vivo following intravenous administration to healthy C57BL/6 mice suggesting no immune activation. HMw HA-tsNPs showed enhanced circulation time and tumor targeting specificity, mainly by accumulating in the tumor and its vicinity compared with LMw HA-tsNPs. Finally, we show that methotrexate (MTX), a drug commonly used in cancer chemotherapy, entrapped in HMw HA-tsNPs slowly diffused from the particles with a half-life of 13.75 days, and improved the therapeutic outcome in a murine B16F10 melanoma model compared with NPs suggesting an active cellular targeting beyond the Enhanced Permeability and Retention (EPR) effect. Taken together, these findings have major implications for the use of high molecular weight HA in nanomedicine as a selective and safe active cellular targeting moiety.Hyaluronan (HA), a naturally occurring high Mw (HMw) glycosaminoglycan, has been shown to play crucial roles in cell growth, embryonic development, healing processes, inflammation, and tumor development and progression. Low Mw (LMw, <10 kDa) HA has been reported to provoke inflammatory responses, such as induction of cytokines, chemokines, reactive nitrogen species and growth factors. Herein, we prepared and characterized two types of HA coated (LMw and HMw) lipid-based targeted and stabilized nanoparticles (tsNPs) and tested their binding to tumor cells expressing the HA receptor (CD44), systemic immunotoxicity, and biodistribution in tumor bearing mice. In vitro, the Mw of the surface anchored HA had a significant influence on the affinity towards CD44 on B16F10 murine melanoma cells. LMw HA-tsNPs exhibited weak binding, while binding of tsNPs coated with HMw HA was characterized by high binding. Both types of tsNPs had no measured effect on cytokine induction in vivo following intravenous administration to healthy C57BL/6 mice suggesting no immune activation. HMw HA-tsNPs showed enhanced circulation time and tumor targeting specificity, mainly by accumulating in the tumor and its vicinity compared with LMw HA-tsNPs. Finally, we show that methotrexate (MTX), a drug commonly used in cancer chemotherapy, entrapped in HMw HA-tsNPs slowly diffused from the particles with a half-life of 13.75 days, and improved the therapeutic outcome in a murine B16F10 melanoma model compared with NPs suggesting an active cellular targeting beyond the Enhanced Permeability and Retention (EPR) effect. Taken together, these findings have major implications for the use of high molecular weight HA in nanomedicine as a selective and safe active cellular targeting moiety. Electronic supplementary information (ESI) available. See DOI: 10.1039/c3nr06102g

  1. An Investigation into the Transportation of Irradiated Uranium/Aluminum Targets from a Foreign Nuclear Reactor to the Chalk River Laboratories Site in Ontario, Canada - 12249

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clough, Malcolm; Jackson, Austin

    2012-07-01

    This investigation required the selection of a suitable cask and development of a device to hold and transport irradiated targets from a foreign nuclear reactor to the Chalk River Laboratories in Ontario, Canada. The main challenge was to design and validate a target holder to protect the irradiated HEU-Al target pencils during transit. Each of the targets was estimated to have an initial decay heat of 118 W prior to transit. As the targets have little thermal mass the potential for high temperature damage and possibly melting was high. Thus, the primary design objective was to conceive a target holdermore » to dissipate heat from the targets. Other design requirements included securing the targets during transportation and providing a simple means to load and unload the targets while submerged five metres under water. A unique target holder (patent pending) was designed and manufactured together with special purpose experimental apparatus including a representative cask. Aluminum dummy targets were fabricated to accept cartridge heaters, to simulate decay heat. Thermocouples were used to measure the temperature of the test targets and selected areas within the target holder and test cask. After obtaining test results, calculations were performed to compensate for differences between experimental and real life conditions. Taking compensation into consideration the maximum target temperature reached was 231 deg. C which was below the designated maximum of 250 deg. C. The design of the aluminum target holder also allowed generous clearance to insert and unload the targets. This clearance was designed to close up as the target holder is placed into the cavity of the transport cask. Springs served to retain and restrain the targets from movement during transportation as well as to facilitate conductive heat transfer. The target holder met the design requirements and as such provided data supporting the feasibility of transporting targets over a relatively long period of time. A suitable transport cask was selected and a device for housing irradiated targets for loading, unloading and transportation has been designed, built and validated. The device was successful in meeting all design requirements for this feasibility study. Experiments were conducted with a custom test facility to confirm that the design met the maximum temperature requirements during shipping. Results from tests showed that the peak temperature in the apparatus was 300 deg. C. By compensating for experimental considerations, such as reduced thermal conductivity of the test cask versus that of the actual cask the expected maximum target temperature reduces to 231 deg. C. This is below the designated peak value of 250 deg. C. It can therefore be concluded, based on the content of this paper and from a heat-removal standpoint, the feasibility of transporting targets from a foreign nuclear reactor to Canada is possible, although further testing with irradiated targets and a full size cask would be a recommended next step. (authors)« less

  2. Development and validation of a duplex real-time PCR assay for the diagnosis of equine piroplasmosis.

    PubMed

    Lobanov, Vladislav A; Peckle, Maristela; Massard, Carlos L; Brad Scandrett, W; Gajadhar, Alvin A

    2018-03-02

    Equine piroplasmosis (EP) is an economically significant infection of horses and other equine species caused by the tick-borne protozoa Theileria equi and Babesia caballi. The long-term carrier state in infected animals makes importation of such subclinical cases a major risk factor for the introduction of EP into non-enzootic areas. Regulatory testing for EP relies on screening of equines by serological methods. The definitive diagnosis of EP infection in individual animals will benefit from the availability of sensitive direct detection methods, for example, when used as confirmatory assays for non-negative serological test results. The objectives of this study were to develop a real-time quantitative polymerase chain reaction (qPCR) assay for simultaneous detection of both agents of EP, perform comprehensive evaluation of its performance and assess the assay's utility for regulatory testing. We developed a duplex qPCR targeting the ema-1 gene of T. equi and the 18S rRNA gene of B. caballi and demonstrated that the assay has high analytical sensitivities for both piroplasm species. Validation of the duplex qPCR on samples from 362 competitive enzyme-linked immunosorbent assay (cELISA)-negative horses from Canada and the United States yielded no false-positive reactions. The assay's performance was further evaluated using samples collected from 430 horses of unknown EP status from a highly endemic area in Brazil. This set of samples was also tested by a single-target 18S rRNA qPCR for T. equi developed at the OIE reference laboratory for EP in Japan, and a previously published single-target 18S rRNA qPCR for B. caballi whose oligonucleotides we adopted for use in the duplex qPCR. Matching serum samples were tested for antibodies to these parasites using cELISA. By the duplex qPCR, T. equi-specific 18S rRNA qPCR and cELISA, infections with T. equi were detected in 87.9% (95% confidence interval, CI: 84.5-90.7%), 90.5% (95% CI: 87.3-92.3%) and 87.4% (95% CI: 84.0-90.2%) of the horses, respectively. The B. caballi prevalence estimates were 9.3% (95% CI: 6.9-12.4%) by the duplex qPCR and 7.9% (95% CI: 5.7-10.9%) by the respective single-target qPCR assay. These values were markedly lower compared to the seroprevalence of 58.6% (95% CI: 53.9-63.2%) obtained by B. caballi-specific cELISA. The relative diagnostic sensitivity of the duplex qPCR for T. equi was 95.5%, as 359 of the 376 horses with exposure to T. equi confirmed by cELISA had parasitemia levels above the detection limit of the molecular assay. In contrast, only 39 (15.5%) of the 252 horses with detectable B. caballi-specific antibodies were positive for this piroplasm species by the duplex qPCR. The duplex qPCR described here performed comparably to the existing single-target qPCR assays for T. equi and B. caballi and will be more cost-effective in terms of results turnaround time and reagent costs when both pathogens are being targeted for disease control and epidemiological investigations. These validation data also support the reliability of the ema-1 gene-specific oligonucleotides developed in this study for confirmatory testing of non-negative serological test results for T. equi by qPCR. However, the B. caballi-specific qPCR cannot be similarly recommended as a confirmatory assay for routine regulatory testing due to the low level of agreement with serological test results demonstrated in this study. Further studies are needed to determine the transmission risk posed by PCR-negative equines with detectable antibodies to B. caballi.

  3. The design and application of a multi-band IR imager

    NASA Astrophysics Data System (ADS)

    Li, Lijuan

    2018-02-01

    Multi-band IR imaging system has many applications in security, national defense, petroleum and gas industry, etc. So the relevant technologies are getting more and more attention in rent years. As we know, when used in missile warning and missile seeker systems, multi-band IR imaging technology has the advantage of high target recognition capability and low false alarm rate if suitable spectral bands are selected. Compared with traditional single band IR imager, multi-band IR imager can make use of spectral features in addition to space and time domain features to discriminate target from background clutters and decoys. So, one of the key work is to select the right spectral bands in which the feature difference between target and false target is evident and is well utilized. Multi-band IR imager is a useful instrument to collect multi-band IR images of target, backgrounds and decoys for spectral band selection study at low cost and with adjustable parameters and property compared with commercial imaging spectrometer. In this paper, a multi-band IR imaging system is developed which is suitable to collect 4 spectral band images of various scenes at every turn and can be expanded to other short-wave and mid-wave IR spectral bands combination by changing filter groups. The multi-band IR imaging system consists of a broad band optical system, a cryogenic InSb large array detector, a spinning filter wheel and electronic processing system. The multi-band IR imaging system's performance is tested in real data collection experiments.

  4. Effects of online cone-beam computed tomography with active breath control in determining planning target volume during accelerated partial breast irradiation.

    PubMed

    Li, Y; Zhong, R; Wang, X; Ai, P; Henderson, F; Chen, N; Luo, F

    2017-04-01

    To test if active breath control during cone-beam computed tomography (CBCT) could improve planning target volume during accelerated partial breast radiotherapy for breast cancer. Patients who were more than 40 years old, underwent breast-conserving dissection and planned for accelerated partial breast irradiation, and with postoperative staging limited to T1-2 N0 M0, or postoperative staging T2 lesion no larger than 3cm with a negative surgical margin greater than 2mm were enrolled. Patients with lobular carcinoma or extensive ductal carcinoma in situ were excluded. CBCT images were obtained pre-correction, post-correction and post-treatment. Set-up errors were recorded at left-right, anterior-posterior and superior-inferior directions. The differences between these CBCT images, as well as calculated radiation doses, were compared between patients with active breath control or free breathing. Forty patients were enrolled, among them 25 had active breath control. A total of 836 CBCT images were obtained for analysis. CBCT significantly reduced planning target volume. However, active breath control did not show significant benefit in decreasing planning target volume margin and the doses of organ-at-risk when compared to free breathing. CBCT, but not active breath control, could reduce planning target volume during accelerated partial breast irradiation. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  5. Comparison of methods for determining the numbers and species distribution of coliform bacteria in well water samples.

    PubMed

    Niemi, R M; Heikkilä, M P; Lahti, K; Kalso, S; Niemelä, S I

    2001-06-01

    Enumeration of coliform bacteria and Escherichia coli is the most widely used method in the estimation of hygienic quality of drinking water. The yield of target bacteria and the species composition of different populations of coliform bacteria may depend on the method.Three methods were compared. Three membrane filtration methods were used for the enumeration of coliform bacteria in shallow well waters. The yield of confirmed coliform bacteria was highest on Differential Coliform agar, followed by LES Endo agar. Differential Coliform agar had the highest proportion of typical colonies, of which 74% were confirmed as belonging to the Enterobacteriaceae. Of the typical colonies on Lactose Tergitol 7 TTC agar, 75% were confirmed as Enterobacteriaceae, whereas 92% of typical colonies on LES Endo agar belonged to the Enterobacteriaceae. LES Endo agar yielded many Serratia strains, Lactose Tergitol 7 TTC agar yielded numerous strains of Rahnella aquatilis and Enterobacter, whereas Differential Coliform agar yielded the widest range of species. The yield of coliform bacteria varied between methods. Each method compared had a characteristic species distribution of target bacteria and a typical level of interference of non-target bacteria. Identification with routine physiological tests to distinct species was hampered by the slight differences between species. High yield and sufficient selectivity are difficult to achieve simultaneously, especially if the target group is diverse. The results showed that several aspects of method performance should be considered, and that the target group must be distinctly defined to enable method comparisons.

  6. EOS/AMSU: A Blackbody Spacecraft Test Targets Operation and Maintenance Manual

    NASA Technical Reports Server (NTRS)

    1998-01-01

    This report describes the spacecraft test targets and readout console as described in section 5.3.3 of the performance specification S-480-80. The spacecraft targets are to be used to provide a well-known radiometric reference for testing the functionality of the AMSU-A instruments at the spacecraft contractor's facility.

  7. The Efficacy of Web-Based and Print-Delivered Computer-Tailored Interventions to Reduce Fat Intake: Results of a Randomized, Controlled Trial

    ERIC Educational Resources Information Center

    Kroeze, Willemieke; Oenema, Anke; Campbell, Marci; Brug, Johannes

    2008-01-01

    Objective: To test and compare the efficacy of interactive- and print-delivered computer-tailored nutrition education targeting saturated fat intake reduction. Design: A 3-group randomized, controlled trial (2003-2005) with posttests at 1 and 6 months post-intervention. Setting: Worksites and 2 neighborhoods in the urban area of Rotterdam.…

  8. Change in Fruit and Vegetable Intake over 24 Months in Older Adults: Results of the SENIOR Project Intervention

    ERIC Educational Resources Information Center

    Greene, Geoffrey W.; Fey-Yensan, Nancy; Padula, Cynthia; Rossi, Susan R.; Rossi, Joseph S.; Clark, Phillip G.

    2008-01-01

    Purpose: We test the efficacy of an intervention based on the transtheoretical model to increase the intake of fruits and vegetables and to describe differences in psychosocial variables based on the achievement of the 5 A Day Program target. Design and Methods: This study is a randomized controlled trial comparing a 12-month fruit and vegetable…

  9. Science Achievement of Elementary and Secondary School Students in Japan: The Results of the IEA Study. NIER Occasional Paper 01/89.

    ERIC Educational Resources Information Center

    Miyake, Misao

    This document reports the state of science achievement of Japanese students based on the Second International Science study conducted in 1983-84. Results are compared to the first study conducted in 1970. The target populations, samples, and structure of the second study are described. Test results including score distribution and high and low…

  10. Development of a peptide nucleic acid polymerase chain reaction clamping assay for semiquantitative evaluation of genetically modified organism content in food.

    PubMed

    Peano, C; Lesignoli, F; Gulli, M; Corradini, R; Samson, M C; Marchelli, R; Marmiroli, N

    2005-09-15

    In the present study a peptide nucleic acid (PNA)-mediated polymerase chain reaction (PCR) clamping method was developed and applied to the detection of genetically modified organisms (GMO), to test PCR products for band identity and to obtain a semiquantitative evaluation of GMO content. The minimal concentration of PNA necessary to block the PCR was determined by comparing PCRs containing a constant amount of DNA in the presence of increasing concentration of target-specific PNA. The lowest PNA concentration at which specific inhibition took place, by the inhibition of primer extension and/or steric hindrance, was the most efficient condition. Optimization of PCR clamping by PNA was observed by testing five different PNAs with a minimum of 13 bp to a maximum of 15 bp, designed on the target sequence of Roundup Ready soybean. The results obtained on the DNA extracted from Roundup Ready soybean standard flour were verified also on DNA extracted from standard flours of maize GA21, Bt176, Bt11, and MON810. A correlation between the PNA concentration necessary for inducing PCR clamping and the percentage of the GMO target sequence in the sample was found.

  11. Near-Infrared Light Responsive Folate Targeted Gold Nanorods for Combined Photothermal-Chemotherapy of Osteosarcoma.

    PubMed

    Li Volsi, Anna; Scialabba, Cinzia; Vetri, Valeria; Cavallaro, Gennara; Licciardi, Mariano; Giammona, Gaetano

    2017-04-26

    Folate-targeted gold nanorods (GNRs) are proposed as selective theranostic agents for osteosarcoma treatment. An amphiphilic polysaccharide based graft-copolymer (INU-LA-PEG-FA) and an amino derivative of the α,β-poly(N-2-hydroxyethyl)-d,l-aspartamide functionalized with folic acid (PHEA-EDA-FA), have been synthesized to act as coating agents for GNRs. The obtained polymer-coated GNRs were characterized in terms of size, shape, zeta potential, chemical composition, and aqueous stability. They protected the anticancer drug nutlin-3 and were able to deliver it efficiently in different physiological media. The ability of the proposed systems to selectively kill tumor cells was tested on U2OS cancer cells expressing high levels of FRs and compared with human bronchial epithelial cells (16HBE) and human dermal fibroblasts (HDFa). The property of the nanosystems of efficiently controlling drug release upon NIR laser irradiation and of acting as an excellent hyperthermia agent as well as Two Photon Luminescence imaging contrast agents was demonstrated. The proposed folate-targeted GNRs have also been tested in terms of chemoterapeutic and thermoablation efficacy on tridimensional (3-D) osteosarcoma models.

  12. Analyzing the most frequent disease loci in targeted patient categories optimizes disease gene identification and test accuracy worldwide.

    PubMed

    Lebo, Roger V; Tonk, Vijay S

    2015-01-21

    Our genomewide studies support targeted testing the most frequent genetic diseases by patient category: (1) pregnant patients, (2) at-risk conceptuses, (3) affected children, and (4) abnormal adults. This approach not only identifies most reported disease causing sequences accurately, but also minimizes incorrectly identified additional disease causing loci. Diseases were grouped in descending order of occurrence from four data sets: (1) GeneTests 534 listed population prevalences, (2) 4129 high risk prenatal karyotypes, (3) 1265 affected patient microarrays, and (4) reanalysis of 25,452 asymptomatic patient results screened prenatally for 108 genetic diseases. These most frequent diseases are categorized by transmission: (A) autosomal recessive, (B) X-linked, (C) autosomal dominant, (D) microscopic chromosome rearrangements, (E) submicroscopic copy number changes, and (F) frequent ethnic diseases. Among affected and carrier patients worldwide, most reported mutant genes would be identified correctly according to one of four patient categories from at-risk couples with <64 tested genes to affected adults with 314 tested loci. Three clinically reported patient series confirmed this approach. First, only 54 targeted chromosomal sites would have detected all 938 microscopically visible unbalanced karyotypes among 4129 karyotyped POC, CVS, and amniocentesis samples. Second, 37 of 48 reported aneuploid regions were found among our 1265 clinical microarrays confirming the locations of 8 schizophrenia loci and 20 aneuploidies altering intellectual ability, while also identifying 9 of the most frequent deletion syndromes. Third, testing 15 frequent genes would have identified 124 couples with a 1 in 4 risk of a fetus with a recessive disease compared to the 127 couples identified by testing all 108 genes, while testing all mutations in 15 genes could have identified more couples. Testing the most frequent disease causing abnormalities in 1 of 8 reported disease loci [~1 of 84 total genes] will identify ~ 7 of 8 reported abnormal Caucasian newborn genotypes. This would eliminate ~8 to 10 of ~10 Caucasian newborn gene sequences selected as abnormal that are actually normal variants identified when testing all ~2500 diseases looking for the remaining 1 of 8 disease causing genes. This approach enables more accurate testing within available laboratory and reimbursement resources.

  13. Airborne Laser Systems Testing and Analysis (essals et analyse des systemes laser embarques)

    DTIC Science & Technology

    2010-04-01

    of Surface/ Paints Reflection Properties (PILASTER targets); • PILASTER Sensors Testing and Calibration; • LOAS Laser System Testing; and • Test...PILASTER targets candidate paints and materials), a Laser Scatter-meter (LSM) was built. To briefly summarise the fundamental concepts involved...Green Painted Target. 7.6.3 Laser Beam Misalignment with Respect to the Beam-Expander Support For measuring the beam misalignment, the beam expander

  14. Effects of variability of practice in music: a pilot study on fast goal-directed movements in pianists

    PubMed Central

    Bangert, Marc; Wiedemann, Anna; Jabusch, Hans-Christian

    2014-01-01

    Variability of Practice (VOP) refers to the acquisition of a particular target movement by practicing a range of varying targets rather than by focusing on fixed repetitions of the target only. VOP has been demonstrated to have beneficial effects on transfer to a novel task and on skill consolidation. This study extends the line of research to musical practice. In a task resembling a barrier-knockdown paradigm, 36 music students trained to perform a wide left-hand interval leap on the piano. Performance at the target distance was tested before and after a 30-min standardized training session. The high-variability group (VAR) practiced four different intervals including the target. Another group (FIX) practiced the target interval only. A third group (SPA) performed spaced practice on the target only, interweaving with periods of not playing. Transfer was tested by introducing an interval novel to either group. After a 24-h period with no further exposure to the instrument, performance was retested. All groups performed at comparable error levels before training, after training, and after the retention (RET) interval. At transfer, however, the FIX group, unlike the other groups, committed significantly more errors than in the target task. After the RET period, the effect was washed out for the FIX group but then was present for VAR. Thus, the results provide only partial support for the VOP hypothesis for the given setting. Additional exploratory observations suggest tentative benefits of VOP regarding execution speed, loudness, and performance confidence. We derive specific hypotheses and specific recommendations regarding sample selection and intervention duration for future investigations. Furthermore, the proposed leap task measurement is shown to be (a) robust enough to serve as a standard framework for studies in the music domain, yet (b) versatile enough to allow for a wide range of designs not previously investigated for music on a standardized basis. PMID:25157223

  15. SU-E-T-245: Detection of the Photon Target Damage in Varian Linac Based On Periodical Quality Assurance Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, S; Balter, P; Wang, X

    2015-06-15

    Purpose: To determine the best dosimetric metric measured by our routine QA devices for diagnosing photon target failure on a Varian C-series linac. Methods: We have retrospectively reviewed and analyzed the dosimetry data from a Varian linac with a target degradation that was undiagnosed for one year. A failure in the daily QA symmetry tests was the first indication of an issue. The beam was steered back to a symmetric shape and water scans indicated the beam energy had changed but stayed within the manufacturer’s specifications and agreed reasonably with our treatment planning system data. After the problem was identifiedmore » and the target was replaced, we retrospectively analyzed our QA data including diagonals normalized flatness (F-DN) from the daily device (DQA3), profiles from an ionization chamber array (IC Profiler), as well as profiles and PDDs from a 3D water Scanner (3DS). These metrics were cross-compared to determine which was the best early indicator of target degradation. Results: A 3% change in FDN measured by the DQA3 was found to be an early indicator of target degradation. It is more sensitive than changes in output, symmetry, flatness or PDD. All beam shape metrics (flatness at dmax and 10 cm depth, and F-DN) indicated an energy increase while the PDD indicated an energy decrease. This disagreement between the beam-shape based energy metrics (F-DN and flatness) and PDD based energy metric may indicate target failure as opposed to an energy change resulting from changes in the incident electron energy. Conclusion: Photon target degradation has been identified as a failure mode for linacs. The manufacturer’s test for this condition is highly invasive and requires machine down time. We have demonstrated that the condition could be caught early based upon data acquired during routine QA activities, such as the F-DN.« less

  16. Association of quantitative magnetic resonance imaging parameters with histological findings from MRI/ultrasound fusion prostate biopsy.

    PubMed

    Dianat, Seyed Saeid; Carter, H Ballentine; Schaeffer, Edward M; Hamper, Ulrik M; Epstein, Jonathan I; Macura, Katarzyna J

    2015-10-01

    Purpose of this pilot study was to correlate quantitative parameters derived from the multiparametric magnetic resonance imaging (MP-MRI) of the prostate with results from MRI guided transrectal ultrasound (MRI/TRUS) fusion prostate biopsy in men with suspected prostate cancer. Thirty-nine consecutive patients who had 3.0T MP-MRI and subsequent MRI/TRUS fusion prostate biopsy were included and 73 MRI-identified targets were sampled by 177 cores. The pre-biopsy MP-MRI consisted of T2-weighted, diffusion weighted (DWI), and dynamic contrast enhanced (DCE) images. The association of quantitative MRI measurements with biopsy histopathology findings was assessed by Mann-Whitney U- test and Kruskal-Wallis test. Of 73 targets, biopsy showed benign prostate tissue in 46 (63%), cancer in 23 (31.5%), and atypia/high grade prostatic intraepithelial neoplasia in four (5.5%) targets. The median volume of cancer-positive targets was 1.3 cm3. The cancer-positive targets were located in the peripheral zone (56.5%), transition zone (39.1%), and seminal vesicle (4.3%). Nine of 23 (39.1%) cancer-positive targets were higher grade cancer (Gleason grade > 6). Higher grade targets and cancer-positive targets compared to benign lesions exhibited lower mean apparent diffusion coefficient (ADC) value (952.7 < 1167.9 < 1278.9), and lower minimal extracellular volume fraction (ECF) (0.13 < 0.185 < 0.213), respectively. The difference in parameters was more pronounced between higher grade cancer and benign lesions. Our findings from a pilot study indicate that quantitative MRI parameters can predict malignant histology on MRI/TRUS fusion prostate biopsy, which is a valuable technique to ensure adequate sampling of MRI-visible suspicious lesions under TRUS guidance and may impact patient management. The DWI-based quantitative measurement exhibits a stronger association with biopsy findings than the other MRI parameters.

  17. Population-level impact of an accelerated HIV response plan to reach the UNAIDS 90-90-90 target in Côte d'Ivoire: Insights from mathematical modeling.

    PubMed

    Maheu-Giroux, Mathieu; Vesga, Juan F; Diabaté, Souleymane; Alary, Michel; Baral, Stefan; Diouf, Daouda; Abo, Kouamé; Boily, Marie-Claude

    2017-06-01

    National responses will need to be markedly accelerated to achieve the ambitious target of the Joint United Nations Programme on HIV/AIDS (UNAIDS). This target aims for 90% of HIV-positive individuals to be aware of their status, for 90% of those aware to receive antiretroviral therapy (ART), and for 90% of those on treatment to have a suppressed viral load by 2020, with each individual target reaching 95% by 2030. We aimed to estimate the impact of various treatment-as-prevention scenarios in Côte d'Ivoire, one of the countries with the highest HIV incidence in West Africa, with unmet HIV prevention and treatment needs, and where key populations are important to the broader HIV epidemic. An age-stratified dynamic model was developed and calibrated to epidemiological and programmatic data using a Bayesian framework. The model represents sexual and vertical HIV transmission in the general population, female sex workers (FSW), and men who have sex with men (MSM). We estimated the impact of scaling up interventions to reach the UNAIDS targets, as well as the impact of 8 other scenarios, on HIV transmission in adults and children, compared to our baseline scenario that maintains 2015 rates of testing, ART initiation, ART discontinuation, treatment failure, and levels of condom use. In 2015, we estimated that 52% (95% credible intervals: 46%-58%) of HIV-positive individuals were aware of their status, 72% (57%-82%) of those aware were on ART, and 77% (74%-79%) of those on ART were virologically suppressed. Reaching the UNAIDS targets on time would avert 50% (42%-60%) of new HIV infections over 2015-2030 compared to 30% (25%-36%) if the 90-90-90 target is reached in 2025. Attaining the UNAIDS targets in FSW, their clients, and MSM (but not in the rest of the population) would avert a similar fraction of new infections (30%; 21%-39%). A 25-percentage-point drop in condom use from the 2015 levels among FSW and MSM would reduce the impact of reaching the UNAIDS targets, with 38% (26%-51%) of infections averted. The study's main limitation is that homogenous spatial coverage of interventions was assumed, and future lines of inquiry should examine how geographical prioritization could affect HIV transmission. Maximizing the impact of the UNAIDS targets will require rapid scale-up of interventions, particularly testing, ART initiation, and limiting ART discontinuation. Reaching clients of FSW, as well as key populations, can efficiently reduce transmission. Sustaining the high condom-use levels among key populations should remain an important prevention pillar.

  18. Population-level impact of an accelerated HIV response plan to reach the UNAIDS 90-90-90 target in Côte d’Ivoire: Insights from mathematical modeling

    PubMed Central

    Diabaté, Souleymane; Alary, Michel; Diouf, Daouda; Abo, Kouamé; Boily, Marie-Claude

    2017-01-01

    Background National responses will need to be markedly accelerated to achieve the ambitious target of the Joint United Nations Programme on HIV/AIDS (UNAIDS). This target aims for 90% of HIV-positive individuals to be aware of their status, for 90% of those aware to receive antiretroviral therapy (ART), and for 90% of those on treatment to have a suppressed viral load by 2020, with each individual target reaching 95% by 2030. We aimed to estimate the impact of various treatment-as-prevention scenarios in Côte d’Ivoire, one of the countries with the highest HIV incidence in West Africa, with unmet HIV prevention and treatment needs, and where key populations are important to the broader HIV epidemic. Methods and findings An age-stratified dynamic model was developed and calibrated to epidemiological and programmatic data using a Bayesian framework. The model represents sexual and vertical HIV transmission in the general population, female sex workers (FSW), and men who have sex with men (MSM). We estimated the impact of scaling up interventions to reach the UNAIDS targets, as well as the impact of 8 other scenarios, on HIV transmission in adults and children, compared to our baseline scenario that maintains 2015 rates of testing, ART initiation, ART discontinuation, treatment failure, and levels of condom use. In 2015, we estimated that 52% (95% credible intervals: 46%–58%) of HIV-positive individuals were aware of their status, 72% (57%–82%) of those aware were on ART, and 77% (74%–79%) of those on ART were virologically suppressed. Reaching the UNAIDS targets on time would avert 50% (42%–60%) of new HIV infections over 2015–2030 compared to 30% (25%–36%) if the 90-90-90 target is reached in 2025. Attaining the UNAIDS targets in FSW, their clients, and MSM (but not in the rest of the population) would avert a similar fraction of new infections (30%; 21%–39%). A 25-percentage-point drop in condom use from the 2015 levels among FSW and MSM would reduce the impact of reaching the UNAIDS targets, with 38% (26%–51%) of infections averted. The study’s main limitation is that homogenous spatial coverage of interventions was assumed, and future lines of inquiry should examine how geographical prioritization could affect HIV transmission. Conclusions Maximizing the impact of the UNAIDS targets will require rapid scale-up of interventions, particularly testing, ART initiation, and limiting ART discontinuation. Reaching clients of FSW, as well as key populations, can efficiently reduce transmission. Sustaining the high condom-use levels among key populations should remain an important prevention pillar. PMID:28617810

  19. Economic evaluation of targeted cancer interventions: critical review and recommendations.

    PubMed

    Elkin, Elena B; Marshall, Deborah A; Kulin, Nathalie A; Ferrusi, Ilia L; Hassett, Michael J; Ladabaum, Uri; Phillips, Kathryn A

    2011-10-01

    Scientific advances have improved our ability to target cancer interventions to individuals who will benefit most and spare the risks and costs to those who will derive little benefit or even be harmed. Several approaches are currently used for targeting interventions for cancer risk reduction, screening, and treatment, including risk prediction algorithms for identifying high-risk subgroups and diagnostic tests for tumor markers and germline genetic mutations. Economic evaluation can inform decisions about the use of targeted interventions, which may be more costly than traditional strategies. However, assessing the impact of a targeted intervention on costs and health outcomes requires explicit consideration of the method of targeting. In this study, we describe the importance of this principle by reviewing published cost-effectiveness analyses of targeted interventions in breast cancer. Few studies we identified explicitly evaluated the relationships among the method of targeting, the accuracy of the targeting test, and outcomes of the targeted intervention. Those that did found that characteristics of targeting tests had a substantial impact on outcomes. We posit that the method of targeting and the outcomes of a targeted intervention are inextricably linked and recommend that cost-effectiveness analyses of targeted interventions explicitly consider costs and outcomes of the method of targeting.

  20. Glucose enhancement of a facial recognition task in young adults.

    PubMed

    Metzger, M M

    2000-02-01

    Numerous studies have reported that glucose administration enhances memory processes in both elderly and young adult subjects. Although these studies have utilized a variety of procedures and paradigms, investigations of both young and elderly subjects have typically used verbal tasks (word list recall, paragraph recall, etc.). In the present study, the effect of glucose consumption on a nonverbal, facial recognition task in young adults was examined. Lemonade sweetened with either glucose (50 g) or saccharin (23.7 mg) was consumed by college students (mean age of 21.1 years) 15 min prior to a facial recognition task. The task consisted of a familiarization phase in which subjects were presented with "target" faces, followed immediately by a recognition phase in which subjects had to identify the targets among a random array of familiar target and novel "distractor" faces. Statistical analysis indicated that there were no differences on hit rate (target identification) for subjects who consumed either saccharin or glucose prior to the test. However, further analyses revealed that subjects who consumed glucose committed significantly fewer false alarms and had (marginally) higher d-prime scores (a signal detection measure) compared to subjects who consumed saccharin prior to the test. These results parallel a previous report demonstrating glucose enhancement of a facial recognition task in probable Alzheimer's patients; however, this is believed to be the first demonstration of glucose enhancement for a facial recognition task in healthy, young adults.

Top