NASA Technical Reports Server (NTRS)
Thompson, William
2002-01-01
The Engineering Test Unit (ETU) of COR1 was made in two configurations. The first configuration, ETU-1, was for vibration testing, while the second, ETU-2, was for optical testing. This is a report on the optical testing performed on ETU-2 at the NCAR/HAO Vacuum Tunnel Facility during the months of October and November, 2002. This was the same facility used to test the two previous breadboard models. In both configurations, the first two tube sections were complete, with all optical elements aligned. The vibration model ETU-1 had the remaining tube sections attached, with mass models for the remaining optics, for the various mechanisms, and for the focal plane assembly. It was then converted into the optical model ETU-2 by removing tube sections 3 to 5, and mounting the remaining optics on commercial mounts. (The bandpass filter was also installed into tube 2, which had been replaced in ETU-1 by a mass model, so that pre- and post-vibration optical measurements could be made.) Doublet 2 was installed in a Newport LP-2 carrier, and aligned to the other optics in the first two tube sections. The LP-2 adjustment screws were then uralened so that the alignment could be maintained during shipping. Because neither the flight polarizer nor Hollow Core Motor were available, they were simulated by a commercial polarizer and rotational mount, both from Oriel corporation. The Oriel rotational stage was not designed for vacuum use, but it was determined after consultation with the company, and lab testing, that the stage could be used in the moderate vacuum conditions at the NCAR/HAO facility. The shutter and focal plane assembly were simulated with the same camera used for the previous two breadboard tests. The focal plane mask was simulated with a plane of BK7 glass with a mask glued on, using the same procedure as for the Lyot spot on Doublet 1, and mounted in an adjustable LP-2 carrier. Two masks were made, one made to the precise specifications of the optical design, the other slightly bigger to make alignment easier.
Biogasification of sorghum in a novel anaerobic digester
DOE Office of Scientific and Technical Information (OSTI.GOV)
Srivastava, V.J.; Biljetina, R.; Isaacson, H.R.
1987-01-01
The Institute of Gas Technology (IGT) conducted pilot-scale anaerobic digestion experiments with ensiled sorghum in a 160 ft/sup 3/ digester at the experimental test unit (ETU) facility at the Walt Disney World Resort Complex in Florida. The study focused on improving bioconversion efficiencies and process stability by employing a novel reactor concept developed at IGT. Steady-state performance data were collected from the ETU as well as from a laboratory-scale conventional stirred tank reactor (CSTR) at loading rates of 0.25 and 0.50 lb organic matter/ft/sup 3/-day at mesophilic and thermophilic temperatures, respectively. This paper will describe the ETU facility, novel digestermore » design and operating techniques, and the results obtained during 12 months of stable and uninterrupted operation of the ETU and the CSTR which showed that methane yields anad rates from the ETU were 20% to 50% higher than those of the CSTR. 10 refs., 7 figs., 5 tabs.« less
Servicers system demonstration plan and capability development
NASA Technical Reports Server (NTRS)
Bulboaca, M. A.; Cuseo, J. A.; Derocher, W. L., Jr.; Maples, R. W.; Reynolds, P. C.; Sterrett, R. A.
1985-01-01
A plan for the demonstration of the exchange of Multi-Mission Modular Spacecraft (MMS) modules using the servicer mechanism Engineering Test Unit (ETU) was prepared and executed. The plan included: establishment of requirements, conceptual design, selection of MMS spacecraft mockup configuration, selection of MMS module mockup configuration, evaluation of adequacy of ETU load capability, and selection of a stowage rack arrangement. The MMS module exchange demonstration mockup equipment was designed, fabricated, checked out, shipped, installed, and demonstrated.
A Spaceflight Magnetic Bearing Equipped Optical Chopper with Six-Axis Active Control
NASA Technical Reports Server (NTRS)
Blumenstock, Kenneth A.; Lee, Kenneth Y.; Schepis, Joseph P.
1998-01-01
This paper describes the development of an ETU (Engineering Test Unit) rotary optical chopper with magnetic bearings. An ETU is required to be both flight-like, nearly identical to a flight unit without the need for material certifications, and demonstrate structural and performance integrity. A prototype breadboard design previously demonstrated the feasibility of meeting flight performance requirements using magnetic bearings. The chopper mechanism is a critical component of the High Resolution Dynamics Limb Sounder (HIRDLS) which will be flown on EOS-CHEM (Earth Observing System-Chemistry). Particularly noteworthy are the science requirements which demand high precision positioning and minimal power consumption along with full redundancy of coils and sensors in a miniature, lightweight package. The magnetic bearings are unique in their pole design to minimize parasitic losses and utilize collocated optical sensing. The motor is of an unusual disk-type ironless stator design. The ETU design has evolved from the breadboard design. A number of improvements have been incorporated into the ETU design. Active thrust control has been added along with changes to improve sensor stability, motor efficiency, and touchdown and launch survivability. It was necessary to do all this while simultaneously reducing the mechanism volume. Flight-like electronics utilize a DSP (Digital Signal Processor) and contain all sensor electronics and drivers on a single five inch by nine inch circuit board. Performance test results are reported including magnetic bearing and motor rotational losses.
Biogasification products of water hyacinth wastewater reclamation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chynoweth, D.P.; Biljetina, R.; Srivastava, V.J.
1984-01-01
This paper describes the results of research in progress to evaluate the use of water hyacinth for wastewater treatment and subsequent conversion of hyacinth and sludge to methane by anaerobic digestion. Laboratory studies have been directed toward evaluating advanced biogasification concepts and establishing a data base for the design and operation of an experimental test unit (ETU) located at the water hyacinth wastewater treatment facility at Walt Disney World (WDW) located in Kissimmee, Florida. Laboratory-scale kinetic experiments have been conducted using continuously-stirred tank reactors (CSTR) and a novel non-mixed upflow solids reactor (USR) receiving a hyacinth/sludge blend at retention timesmore » of 15 down to 2.1 days. The data suggest that best performance is achieved in the USR which has longer solids and organism retention. A larger-scale ETU (160 cu ft) was designed and installed at WDW in 1983 and started up in 1984. The purpose of this unit is to validate laboratory experiments and to evaluate larger-scale equipment used for chopping, slurry preparation, mixing, and effluent dewatering. The ETU includes a front end designed for multiple feed processing and storage, a fully instrumented USR digester, and tanks for effluent and gas storage. The ETU is currently being operated on a 2:1 blend (dry wt basis) of water hyacinth and primary sludge. Performance is good without major operational problems. Results of laboratory studies and start-up and operation of the ETU will be presented. 7 references, 4 figures, 1 table.« less
Biogasification of Walt Disney World biomass waste blend. Annual report, January-December 1983
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biljetina, R.; Chynoweth, D.P.; Janulis, J.
1984-09-01
The objective of this research is to develop efficient processes for conversion of biomass-waste blends to methane and other resources. To evaluate the technical and economic feasibility, an experimental test unit (ETU) was designed and installed at the Reedy Creek Wastewater Treatment Plant at Walt Disney World in Lake Buena Vista, Florida. The facility integrates a biomethanogenic conversion process with a wastewater treatment process employing water hyacinth ponds for secondary and tertiary treatment of sewage. Harvested water hyacinth is subsequently combined with sludge from the primary wastewater clarifier and fed at 1-wet-ton per day to the ETU digester. This resultsmore » in the production of methane and other useful byproducts. Design, procurement of equipment, and installation has been completed. Start-up of the ETU is in progress.« less
Liu, Lei; Yin, Huahua; Liu, Ding
2017-04-01
In November 2014, a total of 164 health care workers were dispatched by the Chinese government as the first medical assistance team to Liberia. The tasks of this team were to establish a China Ebola treatment unit (ETU), to commence the initial admission and treatment of suspected and confirmed Ebola patients, and to provide public health and infection control training for relevant local personnel. Overall, during the 2-month stay of this first medical assistance team in Liberia, 112 Ebola-suspected patients presented to the ETU, 65 patients were admitted, including 5 confirmed cases, and 3 confirmed cases were cured. Furthermore, 1520 local people were trained, including health care workers, military health care workers, staff members employed by the ETU, and community residents. Most importantly, as the first Chinese medical assistance team deployed to Liberia fighting the Ebola virus on the frontline, not a single member of this team or the hired local staff were infected by Ebola virus. This highly successful outcome was due to the meticulous infection control initiatives developed by the team, thereby making a significant contribution to China's ETU "zero infection" of health workers in Liberia. The major infection control initiatives conducted in the China ETU that contributed to achieving "zero infection" of all health workers in the ETU are introduced in this report. (Disaster Med Public Health Preparedness. 2017;11:262-266).
Servicer system demonstration plan and capability development
NASA Technical Reports Server (NTRS)
1987-01-01
An orbital maneuvering vehicle (OMV) front end kit is defined which is capable of performing in-situ fluid resupply and modular maintenance of free flying spacecraft based on the integrated orbital servicing system (IOSS) concept. The compatibility of the IOSS to perform gas and fluid umbilical connect and disconnect functions utilizing connect systems currently available or in development is addressed. A series of tasks involving on-orbit servicing and the engineering test unit (ETU) of the on-orbit service were studied. The objective is the advancement of orbital servicing by expanding the Spacecraft Servicing Demonstration Plan (SSDP) to include detail demonstration planning using the Multimission Modular Spacecraft (MMS) and upgrading the ETU control.
Biogasification of community-derived biomass and solid wastes in a pilot-scale SOLCON reactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Srivastava, V.J.; Biljetina, R.; Isaacson, H.R.
1988-01-01
The Institute of Gas Technology has developed a novel, solids- concentrating (SOLCON) bioreactor to convert a variety of individual or mixed feedstocks (biomass and wastes) to methane at higher rates and efficiencies than those obtained from conventional high-rate anaerobic digesters. The biogasification studies are being conducted in a pilot-scale experimental test unit (ETU) located in the Walt Disney World Resort Complex, Orlando, Florida. This paper describes the ETU facility, the logistics of feedstock integration, the SOLCON reactor design and operating techniques, and the results obtained during 4 years of stable, uninterrupted operation with different feedstocks. The SOLCON reactor consistently outperformedmore » the conventional stirred-tank reactor by 20% to 50%.« less
Thermal Vacuum Testing of a Novel Loop Heat Pipe Design for the Swift BAT Instrument
NASA Technical Reports Server (NTRS)
Ottenstein, Laura; Ku, Jentung; Feenan, David
2003-01-01
An advanced thermal control system for the Burst Alert Telescope on the Swift satellite has been designed and an engineering test unit (ETU) has been built and tested in a thermal vacuum chamber. The ETU assembly consists of a propylene loop heat pipe, two constant conductance heat pipes, a variable conductance heat pipe (VCHP), which is used for rough temperature control of the system, and a radiator. The entire assembly was tested in a thermal vacuum chamber at NASA/GSFC in early 2002. Tests were performed with thermal mass to represent the instrument and with electrical resistance heaters providing the heat to be transferred. Start-up and heat transfer of over 300 W was demonstrated with both steady and variable condenser sink temperatures. Radiator sink temperatures ranged from a high of approximately 273 K, to a low of approximately 83 K, and the system was held at a constant operating temperature of 278 K throughout most of the testing. A novel LHP temperature control methodology using both temperature-controlled electrical resistance heaters and a small VCHP was demonstrated. This paper describes the system and the tests performed and includes a discussion of the test results.
Heatshield for Extreme Entry Environment Technology (HEEET) for Missions to Saturn and Beyond
NASA Technical Reports Server (NTRS)
Ellerby, D.; Blosser, M.; Chinnapongse, R.; Fowler, M.; Gasch, M.; Hamm, K.; Kazemba, C.; Ma, J.; Milos, F.; Nishioka, O.;
2015-01-01
This poster provides an overview of the requirements, design, development and testing of the 3D Woven TPS being developed under NASAs Heatshield for Extreme Entry Environment Technology (HEEET) project. Under this current program, NASA is working to develop a Thermal Protection System (TPS) capable of surviving entry into Saturn. A primary goal of the project is to build and test an Engineering Test Unit (ETU) to establish a Technical Readiness Level (TRL) of 6 for this technology by 2017.
NASA Technical Reports Server (NTRS)
Ellerby, D.; Beerman, A.; Blosser, M.; Boghozian, T.; Chavez-Garcia, J.; Chinnapongse, R.; Fowler, M.; Gage, P.; Gasch, M.; Gonzales, G.;
2015-01-01
This poster provides an overview of the requirements, design, development and testing of the 3D Woven TPS being developed under NASA's Heatshield for Extreme Entry Environment Technology (HEEET) project. Under this current program, NASA is working to develop a Thermal Protection System (TPS) capable of surviving entry into Venus or Saturn. A primary goal of the project is to build and test an Engineering Test Unit (ETU) to establish a Technical Readiness Level (TRL) of 6 for this technology by 2017.
NASA Technical Reports Server (NTRS)
Ellerby, D.; Beerman, A.; Blosser, M.; Boghozian, T.; Chavez-Garcia, J.; Chinnapongse, R.; Fowler, M.; Gage, P.; Gasch, M.; Gonzaes, G.;
2015-01-01
This poster provides an overview of the requirements, design, development and testing of the 3D Woven TPS being developed under NASAs Heatshield for Extreme Entry Environment Technology (HEEET) project. Under this current program, NASA is working to develop a Thermal Protection System (TPS) capable of surviving entry into Venus or Saturn. A primary goal of the project is to build and test an Engineering Test Unit (ETU) to establish a Technical Readiness Level (TRL) of 6 for this technology by 2017.
NASA Technical Reports Server (NTRS)
Ellerby, D.; Blosser, M.; Boghozian, T.; Chavez-Garcia, J.; Chinnapongse, R.; Fowler, M.; Gage, P.; Gasch, M.; Gonzales, G.; Hamm, K.;
2016-01-01
This poster provides an overview of the requirements, design, development and testing of the 3D Woven TPS being developed under NASA's Heatshield for Extreme Entry Environment Technology (HEEET) project. Under this current program, NASA is working to develop a Thermal Protection System (TPS) capable of surviving entry into Saturn. A primary goal of the project is to build and test an Engineering Test Unit (ETU) to establish a Technical Readiness Level (TRL) of 6 for this technology by 2017.
Heatshield for Extreme Entry Environment Technology (HEEET) Development and Maturation Status
NASA Technical Reports Server (NTRS)
Ellerby, D.; Boghozian, T.; Driver, D.; Chavez-Garcia, J.; Fowler, M.; Gage, P.; Gasch, M.; Gonzales, G.; Kazemba, C.; Kellermann, C.;
2018-01-01
This poster provides an overview of the requirements, design, development and testing of the 3D (Three Dimensional) Woven TPS (Thermal Protection System) being developed under NASA's Heatshield for Extreme Entry Environment Technology (HEEET) project. Under this current program, NASA is working to develop a TPS capable of surviving entry into Saturn. A primary goal of the project is to build and test an Engineering Test Unit (ETU) to establish a Technical Readiness Level (TRL) of 6 for this technology by 2017.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Srivastava, V.; Fannin, K.F.; Biljetina, R.
1986-07-01
The Institute of Gas Technology (IGT) conducted a comprehensive laboratory-scale research program to develop and optimize the anaerobic digestion process for producing methane from water hyacinth and sludge blends. This study focused on digester design and operating techniques, which gave improved methane yields and production rates over those observed using conventional digesters. The final digester concept and the operating experience was utilized to design and operate a large-scale experimentla test unit (ETU) at Walt Disney World, Florida. This paper describes the novel digester design, operating techniques, and the results obtained in the laboratory. The paper also discusses a kinetic modelmore » which predicts methane yield, methane production rate, and digester effluent solids as a function of retention time. This model was successfully utilized to predict the performance of the ETU. 15 refs., 6 figs., 6 tabs.« less
RESOLVE (Regolith & Environmental Science Oxygen & Lunar Volatile Extraction) Project
NASA Technical Reports Server (NTRS)
Parker, Ray; Coan, Mary; Captain, Janine; Cryderman, Kate; Quinn, Jacqueline
2015-01-01
The RESOLVE Project is a lunar prospecting mission whose primary goal is to characterize water and other volatiles in lunar regolith. The Lunar Advanced Volatiles Analysis (LAVA) subsystem is comprised of a fluid subsystem that transports flow to the gas chromatograph - mass spectrometer (GC-MS) instruments that characterize volatiles and the Water Droplet Demonstration (WDD) that will capture and display water condensation in the gas stream. The LAVA Engineering Test Unit (ETU) is undergoing risk reduction testing this summer and fall within a vacuum chamber to understand and characterize component and integrated system performance. Testing of line heaters, printed circuit heaters, pressure transducers, temperature sensors, regulators, and valves in atmospheric and vacuum environments was done. Test procedures were developed to guide experimental tests and test reports to analyze and draw conclusions from the data. In addition, knowledge and experience was gained with preparing a vacuum chamber with fluid and electrical connections. Further testing will include integrated testing of the fluid subsystem with the gas supply system, near-infrared spectrometer for the Surge Tank (NIRST), WDD, Sample Delivery System, and GC-MS in the vacuum chamber. Since LAVA is a scientific subsystem, the near infrared spectrometer and GC-MS instruments will be tested during the ETU testing phase.
Crystal structures and vibrational spectroscopy of copper(I) thiourea complexes.
Bowmaker, Graham A; Hanna, John V; Pakawatchai, Chaveng; Skelton, Brian W; Thanyasirikul, Yupa; White, Allan H
2009-01-05
Several synthetic strategies using copper(I) starting materials or copper(II) compounds and an in situ sulfite reductant have been used to systematically explore the chemistry of copper(I) complexes with thiourea and substituted thiourea ligands. This has resulted in the discovery of several new complexes and methods for the bulk synthesis of some previously reported complexes that had been prepared adventitiously in small quantity. The new complexes are (tu = thiourea, dmtu = N,N'-dimethylthiourea, etu = ethylenethiourea): [I(4)Cu(4)(tu)(6)].H(2)O, [Cu(4)(tu)(10)](NO(3)).tu.3H(2)O, [BrCu(dmtu)(3)], [ICu(dmtu)(3)](2), [BrCu(etu)(2)](2), [ICu(etu)(2)], [ICu(etu)(2)](3). [I(4)Cu(4)(tu)(6)].H(2)O has an adamantanoid structure, with four terminal iodide ligands and six doubly bridging tu ligands. In contrast to this, [Cu(4)(tu)(10)](NO(3)).tu.3H(2)O contains a tetranuclear cluster in which four of the tu ligands are terminal and the other six are doubly bridging. [BrCu(dmtu)(3)] is a mononuclear complex with tetrahedral coordination of copper by one bromide and three dmtu ligands, whereas [Cu(dmtu)(3)](2)I(2) has a centrosymmetric dimeric cation with two uncoordinated iodides, four terminal dmtu and two doubly bridging dmtu ligands, [(dmtu)(2)Cu(mu-S-dmtu)(2)Cu(dmtu)(2)]I(2). A reversal of this monomer to dimer trend from bromide to iodide is seen for the etu counterparts: [BrCu(etu)(2)](2) is a centrosymmetric dimer with two doubly bridging etu ligands, [(etu)BrCu(mu-S-etu)(2)CuBr(etu)], whereas [ICu(etu)(2)] is a trigonal planar monomer, although the novel [I(3)Cu(3)(etu)(6)] is also defined. Infrared and Raman spectra of the synthesized complexes were recorded and the metal-ligand vibrational frequencies have been assigned in many cases. The results confirm previously observed correlations between the vibrational frequencies and the corresponding bond lengths for complexes of the unsubstituted tu ligand. A mechanochemical/infrared method was used to synthesize [I(3)Cu(3)(etu)(6)] from CuI and etu, and to demonstrate the polymorphic transition from [ICu(etu)(2)] to [I(3)Cu(3)(etu)(6)].
Decreased Ebola Transmission after Rapid Response to Outbreaks in Remote Areas, Liberia, 2014.
Lindblade, Kim A; Kateh, Francis; Nagbe, Thomas K; Neatherlin, John C; Pillai, Satish K; Attfield, Kathleen R; Dweh, Emmanuel; Barradas, Danielle T; Williams, Seymour G; Blackley, David J; Kirking, Hannah L; Patel, Monita R; Dea, Monica; Massoudi, Mehran S; Wannemuehler, Kathleen; Barskey, Albert E; Zarecki, Shauna L Mettee; Fomba, Moses; Grube, Steven; Belcher, Lisa; Broyles, Laura N; Maxwell, T Nikki; Hagan, Jose E; Yeoman, Kristin; Westercamp, Matthew; Forrester, Joseph; Mott, Joshua; Mahoney, Frank; Slutsker, Laurence; DeCock, Kevin M; Nyenswah, Tolbert
2015-10-01
We measured the reproduction number before and after interventions were implemented to reduce Ebola transmission in 9 outbreaks in Liberia during 2014. We evaluated risk factors for secondary cases and the association between patient admission to an Ebola treatment unit (ETU) and survival. The reproduction number declined 94% from 1.7 (95% CI 1.1-2.6) to 0.1 (95% CI 0.02-0.6) after interventions began. The risk for secondary infections was 90% lower for patients admitted to an ETU (risk ratio 0.1, 95% CI 0.04-0.3) than for those who died in the community. The case-fatality rate was 68% (95% CI 60-74), and ETU admission was associated with a 50% reduction in death (hazard ratio 0.5, 95% CI 0.4-0.8). Isolation and treatment of Ebola patients had the dual benefit of interrupting community transmission and improving survival.
Post-Ebola Syndrome, Sierra Leone.
Scott, Janet T; Sesay, Foday R; Massaquoi, Thomas A; Idriss, Baimba R; Sahr, Foday; Semple, Malcolm G
2016-04-01
Thousands of persons have survived Ebola virus disease. Almost all survivors describe symptoms that persist or develop after hospital discharge. A cross-sectional survey of the symptoms of all survivors from the Ebola treatment unit (ETU) at 34th Regimental Military Hospital, Freetown, Sierra Leone (MH34), was conducted after discharge at their initial follow-up appointment within 3 weeks after their second negative PCR result. From its opening on December 1, 2014, through March 31, 2015, the MH34 ETU treated 84 persons (8-70 years of age) with PCR-confirmed Ebola virus disease, of whom 44 survived. Survivors reported musculoskeletal pain (70%), headache (48%), and ocular problems (14%). Those who reported headache had had lower admission cycle threshold Ebola PCR than did those who did not (p<0.03). This complete survivor cohort from 1 ETU enables analysis of the proportion of symptoms of post-Ebola syndrome. The Ebola epidemic is waning, but the effects of the disease will remain.
Beyond technology acceptance to effective technology use: a parsimonious and actionable model.
Holahan, Patricia J; Lesselroth, Blake J; Adams, Kathleen; Wang, Kai; Church, Victoria
2015-05-01
To develop and test a parsimonious and actionable model of effective technology use (ETU). Cross-sectional survey of primary care providers (n = 53) in a large integrated health care organization that recently implemented new medication reconciliation technology. Surveys assessed 5 technology-related perceptions (compatibility with work values, implementation climate, compatibility with work processes, perceived usefulness, and ease of use) and 1 outcome variable, ETU. ETU was measured as both consistency and quality of technology use. Compatibility with work values and implementation climate were found to have differential effects on consistency and quality of use. When implementation climate was strong, consistency of technology use was high. However, quality of technology use was high only when implementation climate was strong and values compatibility was high. This is an important finding and highlights the importance of users' workplace values as a key determinant of quality of use. To extend our effectiveness in implementing new health care information technology, we need parsimonious models that include actionable determinants of ETU and account for the differential effects of these determinants on the multiple dimensions of ETU. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Decreased Ebola Transmission after Rapid Response to Outbreaks in Remote Areas, Liberia, 2014
Kateh, Francis; Nagbe, Thomas K.; Neatherlin, John C.; Pillai, Satish K.; Attfield, Kathleen R.; Dweh, Emmanuel; Barradas, Danielle T.; Williams, Seymour G.; Blackley, David J.; Kirking, Hannah L.; Patel, Monita R.; Dea, Monica; Massoudi, Mehran S.; Wannemuehler, Kathleen; Barskey, Albert E.; Zarecki, Shauna L. Mettee; Fomba, Moses; Grube, Steven; Belcher, Lisa; Broyles, Laura N.; Maxwell, T. Nikki; Hagan, Jose E.; Yeoman, Kristin; Westercamp, Matthew; Forrester, Joseph; Mott, Joshua; Mahoney, Frank; Slutsker, Laurence; DeCock, Kevin M.; Nyenswah, Tolbert
2015-01-01
We measured the reproduction number before and after interventions were implemented to reduce Ebola transmission in 9 outbreaks in Liberia during 2014. We evaluated risk factors for secondary cases and the association between patient admission to an Ebola treatment unit (ETU) and survival. The reproduction number declined 94% from 1.7 (95% CI 1.1–2.6) to 0.1 (95% CI 0.02–0.6) after interventions began. The risk for secondary infections was 90% lower for patients admitted to an ETU (risk ratio 0.1, 95% CI 0.04–0.3) than for those who died in the community. The case-fatality rate was 68% (95% CI 60–74), and ETU admission was associated with a 50% reduction in death (hazard ratio 0.5, 95% CI 0.4–0.8). Isolation and treatment of Ebola patients had the dual benefit of interrupting community transmission and improving survival. PMID:26402477
Overview of Heatshield for Extreme Entry Environment Technology (HEEET)
NASA Technical Reports Server (NTRS)
Driver, David M.; Ellerby, Donald T.; Gasch, Matthew J.; Mahzari, Milad; Milos, Frank S.; Nishioka, Owen S.; Stackpoole, Margaret M.; Venkatapathy, Ethiraj; Young, Zion W.; Gage, Peter J.;
2018-01-01
The Heatshield for Extreme Entry Environment Technology (HEEET) projects objective is to mature a 3-D Woven Thermal Protection System (TPS) to Technical Readiness Level (TRL) 6 to support future NASA missions to destinations such as Venus and Saturn. The scope of the project, status of which will be discussed, encompasses development of manufacturing and integration processes, fabrication of a prototype 1m diameter engineering test unit (ETU) that will undergo a series of structural tests, characterizing material aerothermal performance including development of a material response model, and structural testing and analysis to develop tools to support design and establish system capability.
Evidence for declining numbers of Ebola cases--Montserrado County, Liberia, June-October 2014.
Nyenswah, Tolbert G; Westercamp, Matthew; Kamali, Amanda Ashraf; Qin, Jin; Zielinski-Gutierrez, Emily; Amegashie, Fred; Fallah, Mosaka; Gergonne, Bernadette; Nugba-Ballah, Roselyn; Singh, Gurudev; Aberle-Grasse, John M; Havers, Fiona; Montgomery, Joel M; Bawo, Luke; Wang, Susan A; Rosenberg, Ronald
2014-11-21
The epidemic of Ebola virus disease (Ebola) in West Africa that began in March 2014 has caused approximately 13,200 suspected, probable, and confirmed cases, including approximately 6,500 in Liberia. About 50% of Liberia's reported cases have been in Montserrado County (population 1.5 million), the most populous county, which contains the capital city, Monrovia. To examine the course of the Ebola epidemic in Montserrado County, data on Ebola treatment unit (ETU) admissions, laboratory testing of patient blood samples, and collection of dead bodies were analyzed. Each of the three data sources indicated consistent declines of 53%-73% following a peak incidence in mid-September. The declines in ETU admissions, percentage of patients with reverse transcription-polymerase chain reaction (RT-PCR) test results positive for Ebola, and dead bodies are the first evidence of reduction in disease after implementation of multiple prevention and response measures. The possible contributions of these interventions to the decline is not yet fully understood or corroborated. A reduction in cases suggests some progress; however, eliminating Ebola transmission is the critical goal and will require greatly intensified efforts for complete, high-quality surveillance to direct and drive the rapid intervention, tracking, and response efforts that remain essential.
Pierce, William F; Ready, Selena D; Chapman, John Tyson; Kulick, Corrinne; Shields, Anastasia; Wang, Jialynn; Andrews, Kimberly; Childs, Richard W; Bell, Carlos; Kosyak, Alexandr; Pham, Jade
2017-09-01
In 2014, the U.S. Public Health Service (USPHS) Commissioned Corps deployed to Monrovia, Liberia, to operate a 25-bed Ebola treatment unit (ETU) constructed by the U.S. Military. The ETU was named the Monrovia Medical Unit (MMU) and was constructed from an U.S. Air Force Expeditionary Medical Support (EMEDS) unit with modifications on the basis of consultation from Médecins Sans Frontières, the World Health Organization, and expert panels from the U.S. Department of Defense and Department of Health and Human Services. From November 12, 2014, to April 30, 2015, 42 patients (18 confirmed Ebola virus disease [EVD] and 24 suspected EVD) from nine countries were treated by USPHS providers at the MMU. The medications used in the MMU were primarily procured from the EMEDS 25-bed pharmacy cache. However, specific formulary additions were made for treatment of EVD. Using the MMU pharmacy dispensing data, we compared and contrasted the medications used in the MMU with recommendations in published EVD treatment guidelines for austere settings. After comparing and contrasting the MMU pharmacy dispensing data with publications with EVD medication recommendations applicable to resource-limited settings, 101 medications were included in the USPHS Essential Medications for the Management of EVD List (EML) for an austere, isolated clinical environment. Because Ebola outbreaks often occur in remote areas, proactive planning, improved preparedness, and optimal patient care for EVD are needed, especially in the context of austere environments with a scarcity of resources. We developed the EML to assist in the planning for future Ebola outbreaks in a remote clinical environment and to provide a list of medications that have been used in an ETU. The EML is a comprehensive medication list that builds on the existing publications with EVD treatment recommendations applicable to supply-constrained clinical environments. As well, it is a resource for the provision of medications when evaluating donations, procurement, and may help inform estimates for product inventory requirements for an ETU. We hope the EML will improve readiness and enhance the capabilities of local and regional international responders. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.
Enhancement of ethylenethiourea recoveries in food analyses by addition of cysteine hydrochloride.
Sack, C A
1995-01-01
The effectiveness of cysteine hydrochloride (Cys-HCl) as a preservative of ethylenethiourea (ETU) in product matrixes and during analysis was studied. ETU recoveries were adversely affected by certain product matrixes when fortified directly into the product. Recoveries in 8 selected food items were 0-92% when analyzed 30 min after fortification and 0-51% when analyzed after 24 h. When Cys-HCl was added to product prior to fortification, recoveries increased to 71-95% even after frozen storage for 2-4 weeks. Cys-HCl was added during analysis of 53 untreated items. Recoveries improved an average of 15% with Cys-HCl. Without Cys-HCl, recoveries were erratic (20-98%), but with Cys-HCl, recoveries were 68-113%. Other antioxidants (sodium sulfite, butylated hydroxyanisole, butylated hydroxytoluene, and vitamins A and C) also were evaluated as ETU preservatives. When lettuce was treated first with sodium sulfite and then fortified with ETU, recoveries averaged 86%; without sodium sulfite, they averaged 1%. The other antioxidants were less effective for preserving ETU in lettuce, giving only 8-46% recoveries. The effect of oxidizers (potassium bromate, sodium hypochlorite, and hydrogen peroxide) on ETU recovery was also determined. Recovery of ETU from a baby food product (pears and pineapple) was 82%; with oxidizers, recoveries were 0-8%.
Mora, Ana María; Córdoba, Leonel; Cano, Juan Camilo; Quesada, Rosario; Faniband, Moosa; Wesseling, Catharina; Ruepert, Clemens; Öberg, Mattias; Eskenazi, Brenda; Mergler, Donna; Lindh, Christian H.
2014-01-01
Background: Mancozeb and its main metabolite ethylene thiourea (ETU) may alter thyroid function; thyroid hormones are essential for fetal brain development. In Costa Rica, mancozeb is aerially sprayed at large-scale banana plantations on a weekly basis. Objectives: Our goals were to evaluate urinary ETU concentrations in pregnant women living near large-scale banana plantations, compare their estimated daily intake (EDI) with established reference doses (RfDs), and identify factors that predict their urinary ETU concentrations. Methods: We enrolled 451 pregnant women from Matina County, Costa Rica, which has large-scale banana production. We visited 445 women up to three times during pregnancy to obtain urine samples (n = 872) and information on factors that possibly influence exposure. We determined urinary ETU concentrations using liquid chromatography mass spectrometry. Results: Pregnant women’s median urinary ETU concentrations were more than five times higher than those reported for other general populations. Seventy-two percent of the women had EDIs above the RfD. Women who lived closest (1st quartile, < 48 m) to banana plantations on average had a 45% (95% CI: 23, 72%) higher urinary ETU compared with women who lived farthest away (4th quartile, ≥ 565 m). Compared with the other women, ETU was also higher in women who washed agricultural work clothes on the day before sampling (11%; 95% CI: 4.9, 17%), women who worked in agriculture during pregnancy (19%; 95% CI: 9.3, 29%), and immigrant women (6.2%; 95% CI: 1.0, 13%). Conclusions: The pregnant women’s urinary ETU concentrations are of concern, and the principal source of exposure is likely to be aerial spraying of mancozeb. The factors predicting ETU provide insight into possibilities for exposure reduction. Citation: van Wendel de Joode B, Mora AM, Córdoba L, Cano JC, Quesada R, Faniband M, Wesseling C, Ruepert C, Öberg M, Eskenazi B, Mergler D, Lindh CH. 2014. Aerial application of mancozeb and urinary ethylene thiourea (ETU) concentrations among pregnant women in Costa Rica: The Infants’ Environmental Health Study (ISA). Environ Health Perspect 122:1321–1328; http://dx.doi.org/10.1289/ehp.1307679 PMID:25198283
Ebola RNA Persistence in Semen of Ebola Virus Disease Survivors - Final Report.
Deen, Gibrilla F; Broutet, Nathalie; Xu, Wenbo; Knust, Barbara; Sesay, Foday R; McDonald, Suzanna L R; Ervin, Elizabeth; Marrinan, Jaclyn E; Gaillard, Philippe; Habib, Ndema; Liu, Hongtu; Liu, William; Thorson, Anna E; Yamba, Francis; Massaquoi, Thomas A; James, Faustin; Ariyarajah, Archchun; Ross, Christine; Bernstein, Kyle; Coursier, Antoine; Klena, John; Carino, Marylin; Wurie, Alie H; Zhang, Yong; Dumbuya, Marion S; Abad, Neetu; Idriss, Baimba; Wi, Teodora; Bennett, Sarah D; Davies, Tina; Ebrahim, Faiqa K; Meites, Elissa; Naidoo, Dhamari; Smith, Samuel J; Ongpin, Patricia; Malik, Tasneem; Banerjee, Anshu; Erickson, Bobbie R; Liu, Yongjian; Liu, Yang; Xu, Ke; Brault, Aaron; Durski, Kara N; Winter, Jörn; Sealy, Tara; Nichol, Stuart T; Lamunu, Margaret; Bangura, James; Landoulsi, Sihem; Jambai, Amara; Morgan, Oliver; Wu, Guizhen; Liang, Mifang; Su, Qiudong; Lan, Yu; Hao, Yanzhe; Formenty, Pierre; Ströher, Ute; Sahr, Foday
2017-10-12
Ebola virus has been detected in the semen of men after their recovery from Ebola virus disease (EVD). We report the presence of Ebola virus RNA in semen in a cohort of survivors of EVD in Sierra Leone. We enrolled a convenience sample of 220 adult male survivors of EVD in Sierra Leone, at various times after discharge from an Ebola treatment unit (ETU), in two phases (100 participants were in phase 1, and 120 in phase 2). Semen specimens obtained at baseline were tested by means of a quantitative reverse-transcriptase-polymerase-chain-reaction (RT-PCR) assay with the use of the target sequences of NP and VP40 (in phase 1) or NP and GP (in phase 2). This study did not evaluate directly the risk of sexual transmission of EVD. Of 210 participants who provided an initial semen specimen for analysis, 57 (27%) had positive results on quantitative RT-PCR. Ebola virus RNA was detected in the semen of all 7 men with a specimen obtained within 3 months after ETU discharge, in 26 of 42 (62%) with a specimen obtained at 4 to 6 months, in 15 of 60 (25%) with a specimen obtained at 7 to 9 months, in 4 of 26 (15%) with a specimen obtained at 10 to 12 months, in 4 of 38 (11%) with a specimen obtained at 13 to 15 months, in 1 of 25 (4%) with a specimen obtained at 16 to 18 months, and in no men with a specimen obtained at 19 months or later. Among the 46 participants with a positive result in phase 1, the median baseline cycle-threshold values (higher values indicate lower RNA values) for the NP and VP40 targets were lower within 3 months after ETU discharge (32.4 and 31.3, respectively; in 7 men) than at 4 to 6 months (34.3 and 33.1; in 25), at 7 to 9 months (37.4 and 36.6; in 13), and at 10 to 12 months (37.7 and 36.9; in 1). In phase 2, a total of 11 participants had positive results for NP and GP targets (samples obtained at 4.1 to 15.7 months after ETU discharge); cycle-threshold values ranged from 32.7 to 38.0 for NP and from 31.1 to 37.7 for GP. These data showed the long-term presence of Ebola virus RNA in semen and declining persistence with increasing time after ETU discharge. (Funded by the World Health Organization and others.).
Onley, H H
1977-09-01
Eight laboratories collaboratively tested a gas-liquid chromatographic method for determining ethylenetiourea (ETU) in potatoes, spinach, applesauce, and milk. In the determinative step, ETU is converted to the S-butyl derivative (2-n-butylmercapto-2-imidazoline) which is detected by a flame photometric detector, sulfur mode. For unknown fortification levels of 0.06, 0.12, and 0.30 ppm, the collaborators reported an overall average recovery range of 85-97% in the various commodities. The method has been adopted as interim official first action.
Gasification of land-based biomass. Final report July 78-December 82
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chynoweth, D.P.; Jerger, D.E.; Conrad, J.R.
1983-06-01
The objective of this research was to develop efficient processes for conversion of land-based biomass to methane and other resources. One task was to determine the relative suitability of selected species or feedstocks for biological and thermal gasification processes. The second task was to narrow options for design and operation of the experimental test unit (ETU) on water hyacinth and sludge at Walt Disney World (WDW) and to provide a scientific base for understanding rate- and yield-limiting reactions for biogasification of these feedstocks, (separately and as blends).
NASA Technical Reports Server (NTRS)
Jackson, C. E., Jr.
1976-01-01
The NTA Level 15.5.2/3, was used to provide non-linear steady-state (NLSS) and non-linear transient (NLTR) thermal predictions for the International Ultraviolet Explorer (IUE) Scientific Instrument (SI). NASTRAN structural models were used as the basis for the thermal models, which were produced by a straight forward conversion procedure. The accuracy of this technique was sub-sequently demonstrated by a comparison of NTA predicts with the results of a thermal vacuum test of the IUE Engineering Test Unit (ETU). Completion of these tasks was aided by the use of NTA subroutines.
Degradation of ethylenethiourea pesticide metabolite from water by photocatalytic processes.
Bottrel, Sue Ellen C; Amorim, Camila C; Leão, Mônica M D; Costa, Elizângela P; Lacerda, Igor A
2014-01-01
In this study, photocatalytic (photo-Fenton and H2O2/UV) and dark Fenton processes were used to remove ethylenethiourea (ETU) from water. The experiments were conducted in a photo-reactor with an 80 W mercury vapor lamp. The mineralization of ETU was determined by total organic carbon analysis, and ETU degradation was qualitatively monitored by the reduction of UV absorbance at 232 nm. A higher mineralization efficiency was obtained by using the photo-peroxidation process (UV/H2O2). Approximately 77% of ETU was mineralized within 120 min of the reaction using [H2O2]0 = 400 mg L(-1). The photo-Fenton process mineralized 70% of the ETU with [H2O2]0 = 800 mg L(-1) and [Fe(2+)] = 400 mg L(-1), and there is evidence that hydrogen peroxide was the limiting reagent in the reaction because it was rapidly consumed. Moreover, increasing the concentration of H2O2 from 800 mg L(-1) to 1200 mg L(-1) did not enhance the degradation of ETU. Kinetics studies revealed that the pseudo-second-order model best fit the experimental conditions. The k values for the UV/H2O2 and photo-Fenton processes were determined to be 6.2 × 10(-4) mg L(-1) min(-1) and 7.7 × 10(-4) mg L(-1) min(-1), respectively. The mineralization of ETU in the absence of hydrogen peroxide has led to the conclusion that ETU transformation products are susceptible to photolysis by UV light. These are promising results for further research. The processes that were investigated can be used to remove pesticide metabolites from drinking water sources and wastewater in developing countries.
NASA Technical Reports Server (NTRS)
Parker, Ray; Coan, Mary; Cryderman, Kate; Captain, Janine
2013-01-01
The RESOLVE project is a lunar prospecting mission whose primary goal is to characterize water and other volatiles in lunar regolith. The Lunar Advanced Volatiles Analysis (LAVA) subsystem is comprised of a fluid subsystem that transports flow to the gas chromatograph - mass spectrometer (GC-MS) instruments that characterize volatiles and the Water Droplet Demonstration (WDD) that will capture and display water condensation in the gas stream. The LAVA Engineering Test Unit (ETU) is undergoing risk reduction testing this summer and fall within a vacuum chamber to understand and characterize component and integrated system performance. Testing of line heaters, printed circuit heaters, pressure transducers, temperature sensors, regulators, and valves in atmospheric and vacuum environments was done. Test procedures were developed to guide experimental tests and test reports to analyze and draw conclusions from the data. In addition, knowledge and experience was gained with preparing a vacuum chamber with fluid and electrical connections. Further testing will include integrated testing of the fluid subsystem with the gas supply system, near-infrared spectrometer, WDD, Sample Delivery System, and GC-MS in the vacuum chamber. This testing will provide hands-on exposure to a flight forward spaceflight subsystem, the processes associated with testing equipment in a vacuum chamber, and experience working in a laboratory setting. Examples of specific analysis conducted include: pneumatic analysis to calculate the WDD's efficiency at extracting water vapor from the gas stream to form condensation; thermal analysis of the conduction and radiation along a line connecting two thermal masses; and proportional-integral-derivative (PID) heater control analysis. Since LAVA is a scientific subsystem, the near-infrared spectrometer and GC-MS instruments will be tested during the ETU testing phase.
Biogasification of Walt Disney World biomass waste blend. Final report, January 1982-December 1985
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biljetina, R.; Chynoweth, D.P.; Srivastava, V.J.
1986-10-01
The objective of the research is to develop efficient processes for conversion of biomass-waste blends to methane and other resources. To evaluate the technical and economic feasibility, an experimental test unit (ETU) was designed and operated at the Reedy Creek Wastewater Treatment Plant at Walt Disney World in Lake Buena Vista, Florida. The facility integrates a biomethanogenic-conversion process with a wastewater-treatment process employing water hyacinth ponds for secondary and tertiary treatment of sewage. Harvested water hyacinth is subsequently combined with sludge from the primary wastewater clarifier and fed at 1-wet-ton per day to the ETU digester. This results in themore » production of methane and other useful products. The digester was operated as a non-mixed, solids concentrating digester to encourage higher solids and microorganism retention times. Data collected during six steady-state operating periods confirmed earlier laboratory observations that this digester consistently produces 15 to 25% higher methane yields and conversions when compared to conventional stirred-tank digester. Digester operation was evaluated at different loading rates, solids blend ratios and feed configurations. Results from the program have provided a data base for the design of larger conversion systems.« less
Fetterly, Gerald J; Grasela, Thaddeus H; Sherman, Jeffrey W; Dul, Jeanne L; Grahn, Amy; Lecomte, Diane; Fiedler-Kelly, Jill; Damjanov, Nevena; Fishman, Mayer; Kane, Michael P; Rubin, Eric H; Tan, Antoinette R
2008-09-15
To evaluate the maximum tolerated dose (MTD), dose-limiting toxicities (DLT), and pharmacokinetics of liposome-entrapped paclitaxel easy-to-use (LEP-ETU) and to characterize the relationship between LEP-ETU concentrations and the time course of neutropenia in cancer patients. LEP-ETU was administered to 88 patients and 63 were evaluable for pharmacokinetic/pharmacodynamic (PK/PD) analysis following 1.5- and 3-h infusions every 3 weeks (q3w; dose range, 135-375 mg/m(2)). MTD was identified using a 3 + 3, up-and-down dose-finding algorithm. PK/PD modeling was done to describe the temporal relationship between paclitaxel concentrations and neutrophil count. Simulations assessed the influence of dose and schedule on neutropenia severity to help guide dose selection. The MTD of LEP-ETU was identified as 325 mg/m(2). DLTs occurring at 375 mg/m(2) consisted of febrile neutropenia and neuropathy. The C(max) and area under the plasma concentration-time curve of LEP-ETU were less than proportional with increasing dose. The PK/PD model showed that LEP-ETU inhibition of neutrophil proliferation was 9.1% per 10 mug/mL of total paclitaxel concentration. The incidence of grade 4 neutropenia increased from 33% to 42% across the dose range of 275 to 325 mg/m(2) q3w. For a dose of 110 mg/m(2) given weekly, grade 4 neutropenia was estimated to be 16% compared with 42% for the same total dose administered q3w. LEP-ETU can be administered safely at higher doses than Taxol. Modeling and simulation studies predict that 325 mg/m(2) LEP-ETU q3w provides acceptable neutropenic events relative to those observed at 175 mg/m(2) Taxol q3w. A 275 mg/m(2) dose may offer an improved therapeutic index.
Bottrel, Sue Ellen C; Pereira, Pedro C; de Oliveira Pereira, Renata; Leão, Mônica M D; Amorim, Camila C
2018-06-25
Ethylenethiourea (ETU) is a toxic degradation product of one class of fungicide which is largely employed in the world, the ethylenebisdithiocarbamates. In this study, ETU was degraded by ozonation enhanced by UV-C light irradiation (O 3 /UV-C) in aqueous medium. Degradation experiments were conducted at natural pH (6.8) and neutral pH (7.0, buffered). ETU was promptly eliminated from the reactive medium during ozonation in the presence and absence of light. Within the first few minutes of reaction conducted in natural pH, the pH decreased quickly from 6.8 to 3.0. Results show that ETU mineralization occurs only in the reaction conducted in neutral pH and that it takes place in a higher rate when enhanced by UV-C irradiation. Main intermediates formed during the O3/UV-C experiments in different conditions tested were also investigated and three different degradation mechanisms were proposed considering the occurrence of direct and indirect ozone reactions. At pH 7, ethylene urea (EU) was quickly generated and degraded. Meanwhile, at natural pH, besides EU, other compounds originated from the electrophilic attack of ozone to the sulfur atom present in the contaminant molecule were also identified during reaction and EU was detected within 60 min of reaction. Results showed that ozonation enhanced by UV-C promotes a faster reaction than the same system in the absence of light, and investigation of the toxicity is recommended.
40 CFR 86.1360-2007 - Supplemental emission test; test cycle and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) * (MZ-MRS) / (MTU-MRS) ETU = ET + (EU-ET) * (nZ-nRT) / (nSU-nRT) ERS = ER + (ES-ER) * (nZ-nRT) / (nSU-n..., ET, EU = for each regulated pollutant, brake specific gaseous emissions of the enveloping modes...
Integrated Risk Information System (IRIS)
Ethylene thiourea ( ETU ) ; CASRN 96 - 45 - 7 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarci
Kontou, S; Tsipi, D; Tzia, C
2004-11-01
The effect of storage at 5 degrees C and of thermal processing by cooking at 100 degrees C and sterilization at 121 degrees C for 15 min on maneb residues in tomato homogenates was investigated. Remaining maneb and its toxic metabolite ethylenethiourea (ETU) were measured after each treatment by headspace gas chromatography with flame-photometric detection and by high-performance liquid chromatography with photo-diode array detection, respectively. No significant loss of maneb was observed during cold storage for up to 6 weeks, taking into account analytical variability. Conversely, thermal treatment resulted in substantial degradation of maneb with extensive conversion to ETU. After cooking, only 26 +/- 1% (+/- SE, n = 8) of initial maneb residues remained in the samples, whilst the conversion to ETU was 28 +/- 1% (mol mol(-1)) (+/- SE, n = 4). Sterilization eliminated the residues of the parent compound giving rise to conversion to ETU up to 32 +/- 1% (mol mol(-1)) (+/- SE, n = 4).
Anaerobic digestion of water hyacinth and sludge
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biljetina, R.; Srivastava, V.J.; Chynoweth, D.P.
1986-01-01
The Institute of Gas Technology (IGT) has been operating an experimental test unit (ETU) at the Walt Disney World (WDW) wastewater treatment plant to demonstrate the conversion of water hyacinth and sludge to methane in a solids concentrating (SOLCON) digester. Results from 2 years to operation have confirmed earlier laboratory observations that this digester achieves higher methane yields and solids conversion than those observed in continuous stirred tank reactors. Methane yields as high as 0.49 m/sup 3/ kg/sup -1/ (7.9 SCF/lb) volatile solids added have been obtained during steady-state operation on a blend of water hyacinth and sludge. 9 refs.,more » 5 figs., 5 tabs.« less
NASA Technical Reports Server (NTRS)
Stysley, Paul; Coyle, Barry; Clarke, Greg; Poulios, Demetrios; Kay, Richard
2015-01-01
The Global Ecosystems Dynamics Investigation (GEDI) is a planned mission sending a LIDAR instrument to the International Space Station that will employ three NASA laser transmitters. This instrument will produce parallel tracks on the Earth's surface that will provide global 3D vegetation canopy measurements. To meet the mission goals a total of 5 High Output Maximum Efficiency Resonator lasers will to be built (1 ETU + 3 Flight + 1 spare) in-house at NASA-GSFC. This presentation will summarize the HOMER design, the testing the design has completed in the past, and the plans to successfully build the units needed for the GEDI mission.
Factors Underlying Ebola Virus Infection Among Health Workers, Kenema, Sierra Leone, 2014-2015.
Senga, Mikiko; Pringle, Kimberly; Ramsay, Andrew; Brett-Major, David M; Fowler, Robert A; French, Issa; Vandi, Mohamed; Sellu, Josephine; Pratt, Christian; Saidu, Josephine; Shindo, Nahoko; Bausch, Daniel G
2016-08-15
Ebola virus disease (EVD) in health workers (HWs) has been a major challenge during the 2014-2015 outbreak. We examined factors associated with Ebola virus exposure and mortality in HWs in Kenema District, Sierra Leone. We analyzed data from the Sierra Leone National Viral Hemorrhagic Fever Database, contact tracing records, Kenema Government Hospital (KGH) staff and Ebola Treatment Unit (ETU) rosters, and burial logs. From May 2014 through January 2015, 600 cases of EVD originated in Kenema District, including 92 (15%) HWs, 66 (72%) of whom worked at KGH. Among KGH medical staff and international volunteers, 18 of 62 (29%) who worked in the ETU developed EVD, compared with 48 of 83 (58%) who worked elsewhere in the hospital. Thirteen percent of HWs with EVD reported contact with EVD patients, while 27% reported contact with other infected HWs. The number of HW EVD cases at KGH declined roughly 1 month after implementation of a new triage system at KGH and the opening of a second ETU within the district. The case fatality ratio for HWs and non-HWs with EVD was 69% and 74%, respectively. The cluster of HW EVD cases in Kenema District is one of the largest ever reported. Most HWs with EVD had potential virus exposure both inside and outside of hospitals. Prevention measures for HWs must address a spectrum of infection risks in both formal and informal care settings as well as in the community. © 2016 World Health Organization; licensee Oxford Journals.
Irenge, Leonid M; Dindart, Jean-Michel; Gala, Jean-Luc
2017-10-26
During the West Africa Ebola virus disease (EVD) outbreak, a Belgian laboratory was deployed for supporting the Ebola treatment unit (ETU) of N'Zerekore, Guinea. Besides diagnosis of EVD and malaria, biochemical parameters were tested and used to guide supportive treatment of EVD. To preserve analytes stability, lithium-heparin blood samples were analyzed using the i-STAT® point-of-care testing (POCT) handheld device without the viral inactivation step. To mitigate the risk of Ebola virus transmission, assays were performed inside a portable glovebox with strict biosafety procedures. Providing the medical staff with real-time biochemical data modified their therapeutic attitude, shifting from empiric to a semi-intensive laboratory-guided treatment of hydro-electrolytic disturbances, metabolic acidosis and/or impaired kidney function. As illustrated with representative EVD cases (n=8), optimized supportive treatment with intravenous fluid therapy and electrolyte replacement often helped correct these abnormalities. However, the harsh operating conditions, especially the use of bleach decontamination inside the glovebox, caused several technical failures and the final breakdown of the POCT device. POCT availability resulted in a paradigm shift in laboratory practice and care delivery at the N'Zerekore ETU. We conclude that there is urgent need for novel well-designed and validated POCT devices usable by non-expert operators in high ambient temperature and limited space. These devices should withstand regular and thorough decontamination by the personnel working on-site with life-threatening pathogens and be compatible with high biosafety level procedures. Such specific users' requirements need a European validation and standardization process of proposed solutions led by the EU Standardization Committee (CEN).
Biogasification of Walt Disney World biomass waste blend. Annual report Jan-Dec 82
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biljetina, R.; Chynoweth, D.P.; Janulis, J.
1983-05-01
The objective of this research is to develop efficient processes for conversion of biomass-waste blends to methane and other resources. To evaluate the technical and economic feasibility, an experimental test facility (ETU) is being designed and installed at the Reedy Creek Wastewater Treatment Plant at Walt Disney World, Orlando, Florida. The facility will integrate a biomethanogenic conversion process with a waste-water treatment process employing water hyacinth ponds for secondary and tertiary treatment of sewage produced at Walt Disney World. The ETU will be capable of feeding 1-wet ton per day of water hyacinth-sludge blends to the digestion system for productionmore » of methane and other byproducts. The detailed design of the facility has been completed and procurement of equipment is in progress.« less
Factors Underlying Ebola Virus Infection Among Health Workers, Kenema, Sierra Leone, 2014–2015
Senga, Mikiko; Pringle, Kimberly; Ramsay, Andrew; Brett-Major, David M.; Fowler, Robert A.; French, Issa; Vandi, Mohamed; Sellu, Josephine; Pratt, Christian; Saidu, Josephine; Shindo, Nahoko; Bausch, Daniel G.
2016-01-01
Background. Ebola virus disease (EVD) in health workers (HWs) has been a major challenge during the 2014–2015 outbreak. We examined factors associated with Ebola virus exposure and mortality in HWs in Kenema District, Sierra Leone. Methods. We analyzed data from the Sierra Leone National Viral Hemorrhagic Fever Database, contact tracing records, Kenema Government Hospital (KGH) staff and Ebola Treatment Unit (ETU) rosters, and burial logs. Results. From May 2014 through January 2015, 600 cases of EVD originated in Kenema District, including 92 (15%) HWs, 66 (72%) of whom worked at KGH. Among KGH medical staff and international volunteers, 18 of 62 (29%) who worked in the ETU developed EVD, compared with 48 of 83 (58%) who worked elsewhere in the hospital. Thirteen percent of HWs with EVD reported contact with EVD patients, while 27% reported contact with other infected HWs. The number of HW EVD cases at KGH declined roughly 1 month after implementation of a new triage system at KGH and the opening of a second ETU within the district. The case fatality ratio for HWs and non-HWs with EVD was 69% and 74%, respectively. Conclusions. The cluster of HW EVD cases in Kenema District is one of the largest ever reported. Most HWs with EVD had potential virus exposure both inside and outside of hospitals. Prevention measures for HWs must address a spectrum of infection risks in both formal and informal care settings as well as in the community. PMID:27193749
NASA Technical Reports Server (NTRS)
Parker, Ray O.
2012-01-01
The RESOLVE project is a lunar prospecting mission whose primary goal is to characterize water and other volatiles in lunar regolith. The Lunar Advanced Volatiles Analysis (LAVA) subsystem is comprised of a fluid subsystem that transports flow to the gas chromatograph- mass spectrometer (GC-MS) instruments that characterize volatiles and the Water Droplet Demonstration (WDD) that will capture and display water condensation in the gas stream. The LAVA Engineering Test Unit (ETU) is undergoing risk reduction testing this summer and fall within a vacuum chamber to understand and characterize C!Jmponent and integrated system performance. Ray will be assisting with component testing of line heaters, printed circuit heaters, pressure transducers, temperature sensors, regulators, and valves in atmospheric and vacuum environments. He will be developing procedures to guide these tests and test reports to analyze and draw conclusions from the data. In addition, he will gain experience with preparing a vacuum chamber with fluid and electrical connections. Further testing will include integrated testing of the fluid subsystem with the gas supply system, near-infrared spectrometer, WDD, Sample Delivery System, and GC-MS in the vacuum chamber. This testing will provide hands-on exposure to a flight forward spaceflight subsystem, the processes associated with testing equipment in a vacuum chamber, and experience working in a laboratory setting. Examples of specific analysis Ray will conduct include: pneumatic analysis to calculate the WOO's efficiency at extracting water vapor from the gas stream to form condensation; thermal analysis of the conduction and radiation along a line connecting two thermal masses; and proportional-integral-derivative (PID) heater control analysis. In this Research and Technology environment, Ray will be asked to problem solve real-time as issues arise. Since LAVA is a scientific subsystem, Ray will be utilizing his chemical engineering background to operate the near-infrared spectrometer and GC-MS instruments during ETU testing. Ray will be working with Modified Commercial off the Shelf (MCOTS) instruments and characterizing their analytical behavior for optimization. Ray will be offered the opportunity to suggest testing modifications or configuration changes at any time to improve the experimental effectiveness. He will gain many skills needed for working in a technical team setting requiring flexibility and critical thinking.
Carias, Cristina; Greening, Bradford; Campbell, Caresse G; Meltzer, Martin I; Hamel, Mary J
2016-04-01
After the detection of an Ebola virus disease outbreak in west Africa in 2014, one of the elements of the response was to contact trace and isolate patients in specialised Ebola treatment units (ETUs) at onset of fever. We aimed to assess the economic feasibility of administering preventive malaria treatment to all contacts of patients with Ebola virus disease, to prevent the onset of febrile malaria and subsequent admission to ETUs. We used a decision tree model to analyse the costs of preventive malaria treatment (artemisinin-based combination treatment [ACT]) for all contacts of patients with Ebola virus disease (in terms of administration and averted ETU-stay costs) and benefits (in terms of averted ETU admissions) in west Africa, from a health-care provider perspective. The period of analyses was 1 year, which is roughly similar to the duration of the 2014-15 west Africa Ebola outbreak response. We calculated the intervention's cost per ETU admission averted (average cost-effectiveness ratio) by season (wet and dry), country (Liberia, Sierra Leone, and Guinea), and age of contact (<5 years, 5-14 years, and ≥15 years). We did sensitivity analyses to assess how results varied with malaria parasite prevalence (in children aged 2-10 years), daily cost of ETU stay (for Liberian malaria incidence levels), and compliance and effectiveness of preventive malaria treatment. Administration of ACTs to contacts of patients with Ebola virus disease was cost saving for contacts of all ages in Liberia, Sierra Leone, and Guinea, in both seasons, from a health-care provider perspective. In the wet season, preventive malaria treatment was estimated to reduce the probability of a contact being admitted to an ETU by a maximum of 36% (in Guinea, for contacts aged <5 years), and a minimum of 10% (in Guinea and Sierra Leone, for those aged ≥15 years). Assuming 85% compliance and taking into account the African population pyramid, the intervention is expected to be cost saving in contacts of all age groups in areas with malaria parasite prevalence in children aged 2-10 years as low as 10%. In Liberia during the wet season, malaria preventive treatment was cost saving even when average daily bed-stay costs were as low as US$5 for children younger than 5 years, $9 for those aged 5-14 years, and $22 for those aged 15 years or older. Administration of preventive malaria treatment to contacts of patients with Ebola virus disease should be considered by public health officials when addressing Ebola virus disease outbreaks in countries and seasons where malaria reaches high levels of transmission. Centers for Disease Control and Prevention. Copyright © 2016 Elsevier Ltd. All rights reserved.
COR1 Engineering Test Unit Measurements at the Mauna Loa Solar Observatory, September 2003
NASA Technical Reports Server (NTRS)
Thompson, William; Reginald, Nelson; Streander, Kim
2003-01-01
The COR1 Engineering Test Unit (ETU), which had been previously tested at the NCAR/HAO and NRL test facilities, was modified into an instrument capable of observing the Sun. It was then taken to the Mauna Loa Solar Observatory to observe the corona. The changes made to observe the Sun were as follows: 1. The plate scale was changed to accommodate the smaller Apogee camera. This change had already been made for the NRL tests. 2. The previous Oriel polarizer was replaced with a commercial Polarcor polarizer from Newport to be more flight-like. However, because of cost and availability considerations, this polarizer was smaller than those which will be used for flight. 3. A structure was placed around the back section of the instrument, to protect it from stray light. 4. A pointing spar borrowed from HAO was used to track the Sun. A few days into the test, it became evident that some artifacts were appearing in the data, and these artifacts were changing as the polarizer was rotated. It was decided to test two other polarizers, the Oriel polarizer which had been used in the previous tests at HAO and NRL, and a Nikon polarizer which was borrowed from a camera belonging to one of the observatory staff members. These three polarizers had much different qualities are shown.
Experimental digester facility modifications and digester gas upgrading research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Srivastava, V.J.; Biljetina, R.; Akin, C.
1989-01-01
The Institute of Gas Technology (IGT) has been participating in an experimental program at the Community Waste Research Facility (CWRF) located at the Walt Disney World Resort Complex, Orlando, Florida. Four institutions have formed a team to provide solutions to community waste treatment and disposal programs. Of primary importance to this research effort is the implementation of low-cost, energy-efficient waste treatment and recovery technologies and the net production of energy (methane) from biomass and waste resources. The production of methane is being studied in a novel, high-rate digester. During 1988, we were responsible for modifying the Experimental Test Unit (ETU)more » to permit dry solids feeding of refuse-derived fuel (RDF) and for conducting bench-scale experiments to evaluate techniques for efficient removal of carbon dioxide produced during anaerobic digestion.« less
Iodine nutritional status and thyroid effects of exposure to ethylenebisdithiocarbamates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Medda, Emanuela
Introduction: Italy is still characterized by a mild iodine deficiency and is among the most intensive users of chemical products for agriculture in Europe. The aim of this study was i) to evaluate thyroid effects of exposure to mancozeb, a fungicide widely used in agriculture, in a sample of Italian grapevine workers, and ii) to verify whether the iodine intake may modulate the risk of thyroid disruption due to the mancozeb metabolite ethylenthiourea (ETU). Methods: One hundred seventy-seven occupationally exposed male workers (29 from Chianti, a mild iodine deficient area, and 148 from Bolzano an iodine sufficient province) and 74more » non-occupationally exposed male controls (34 from Chianti and 40 from Bolzano) were enrolled in the study. Serum biomarkers of thyroid function, as well as urinary iodine and ETU concentrations were assessed. Moreover all the recruited subjects underwent clinical examination and thyroid ultrasound. Results: Multivariate comparisons showed lower mean serum levels of FT4 in Chianti-workers as compared to Bolzano-workers. Moreover, an increased urinary iodine excretion (>250 µg/L) was more frequently found among more exposed workers (ETU>20 µg/L) than among less exposed ones and this effect was more pronounced in Chianti- than in Bolzano-workers. Chianti-workers also showed a significantly higher frequency of very low thyroid volume (≤6.0 ml) as compared to controls. Conclusions: These findings showed a mild thyroid disrupting effect due to occupational exposure to mancozeb, more pronounced in workers residing in an area characterized by a mild to moderate iodine deficiency as compared to workers residing in an area covered by a long-lasting iodine prophylaxis program. - Highlights: • Thyroid is vulnerable to endocrine disrupting effects due to environmental exposures. • Mancozeb is a fungicide widely used in agriculture worldwide. • Mancozeb is broken down into ethylenthiourea (ETU) which has anti-thyroid activity. • Iodine intake may modulate thyroid disruption due to occupational exposure to ETU.« less
Matanock, Almea; Arwady, M Allison; Ayscue, Patrick; Forrester, Joseph D; Gaddis, Bethany; Hunter, Jennifer C; Monroe, Benjamin; Pillai, Satish K; Reed, Christie; Schafer, Ilana J; Massaquoi, Moses; Dahn, Bernice; De Cock, Kevin M
2014-11-21
West Africa is experiencing the largest Ebola virus disease (Ebola) epidemic in recorded history. Health care workers (HCWs) are at increased risk for Ebola. In Liberia, as of August 14, 2014, a total of 810 cases of Ebola had been reported, including 10 clusters of Ebola cases among HCWs working in facilities that were not Ebola treatment units (non-ETUs). The Liberian Ministry of Health and Social Welfare and CDC investigated these clusters by reviewing surveillance data, interviewing county health officials, HCWs, and contact tracers, and visiting health care facilities. Ninety-seven cases of Ebola (12% of the estimated total) were identified among HCWs; 62 HCW cases (64%) were part of 10 distinct clusters in non-ETU health care facilities, primarily hospitals. Early recognition and diagnosis of Ebola in patients who were the likely source of introduction to the HCWs (i.e., source patients) was missed in four clusters. Inconsistent recognition and triage of cases of Ebola, overcrowding, limitations in layout of physical spaces, lack of training in the use of and adequate supply of personal protective equipment (PPE), and limited supervision to ensure consistent adherence to infection control practices all were observed. Improving infection control infrastructure in non-ETUs is essential for protecting HCWs. Since August, the Liberian Ministry of Health and Social Welfare with a consortium of partners have undertaken collaborative efforts to strengthen infection control infrastructure in non-ETU health facilities.
Kinetics and advanced digester design for anaerobic digestion of water hyacinth and primary sludge
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chynoweth, D.P.; Dolenc, D.A.; Ghosh, S.
1982-01-01
A research program centered around a facility located at Walt Disney World (WDW) is in progress to evaluate the use of water hyacinth (WH) for secondary and tertiary wastewater treatment, to optimize growth of WH under these conditions, and to convert the resultant primary sludge (PS) and WH to methane via anaerobic digestion. This article describes the status of the biogasification component of this program, which includes baseline and advanced digestion experiments with individual feeds and blends and the design of an experimental test unit (ETU) to be installed at WDW. Experiments with several blends demonstrated that methane yields canmore » be predicted from the fractional content and methane yield of each component. The process was found to adhere to the Monod kinetic model for microbial growth, and associated kinetic parameters were developed for various feed combinations. A novel upflow digester is achieving significantly higher conversion than a stirred-tank digester. Of several pretreatment techniques used, only alkaline treatment resulted in increased biodegradability. A larger scale (4.5 m/sup 3/) experimental test unit is being designed for installation at WDW in 1982. 13 figures, 4 tables.« less
NASA Astrophysics Data System (ADS)
Brinckerhoff, W. B.; van Amerom, F.; Danell, R.; Pinnick, V. T.; Arevalo, R. D.; Li, X.; Hovmand, L.; Siljestrom, S.; Mahaffy, P. R.; Goetz, W.; Goesmann, F.; Steininger, H.
2013-12-01
The 2018 ExoMars rover mission includes the Mars Organic Molecule Analyzer (MOMA) investigation. MOMA will examine the chemical composition of samples acquired from depths of up to two meters below the martian surface, where organics may be protected from radiative and oxidative degradation. When combined with the complement of instruments in the rover's Pasteur Payload, MOMA has the potential to reveal the presence of a wide range of organics preserved in a variety of mineralogical environments, and to begin to understand the structural character and potential origin of those compounds. MOMA includes an ion trap mass spectrometer (ITMS) that is designed to analyze molecular composition of (i) gas evolved from pyrolyzed powder samples and separated on a gas chromatograph and (ii) ions directly desorbed from solid samples at Mars ambient pressure using a pulsed laser and a fast-valve capillary ion inlet system. This 'dual source' approach gives MOMA unprecedented breadth of detection over a wide range of molecular weights and volatilities. Analysis of nonvolatile, higher-molecular weight organics such as carboxylic acids and peptides even in the presence of significant perchlorate concentrations is enabled by the extremely short (~1 ns) pulses of the desorption laser. Use of the ion trap's tandem mass spectrometry mode permits selective focus on key species for isolation and controlled fragmentation, providing structural analysis capabilities. The flight-like engineering test unit (ETU) of the ITMS, now under construction, will be used to verify breadboard performance with high fidelity, while simultaneously supporting the development of analytical scripts and spectral libraries using synthetic and natural Mars analog samples guided by current results from MSL. ETU campaign data will strongly advise the specifics of the calibration applied to the MOMA flight model as well as the science operational procedures during the mission.
Linear Ion Trap for the Mars Organic Molecule Analyzer
NASA Astrophysics Data System (ADS)
Brinckerhoff, William; Arevalo, Ricardo; Danell, Ryan; van Amerom, Friso; Pinnick, Veronica; Li, Xiang; Hovmand, Lars; Getty, Stephanie; Mahaffy, Paul; Goesmann, Fred; Steininger, Harald
2014-05-01
The 2018 ExoMars rover mission includes the Mars Organic Molecule Analyzer (MOMA) investigation. MOMA will examine the chemical composition of samples acquired from depths of up to two meters below the martian surface, where organics may be protected from radiative and oxidative degradation. When combined with the complement of instruments in the rover's Pasteur Payload, MOMA has the potential to reveal the presence of a wide range of organics preserved in a variety of mineralogical environments, and to begin to understand the structural character and potential origin of those compounds. MOMA includes a linear, or 2D, ion trap mass spectrometer (ITMS) that is designed to analyze molecular composition of (i) gas evolved from pyrolyzed powder samples and separated on a gas chromatograph and (ii) ions directly desorbed from solid samples at Mars ambient pressure using a pulsed laser and a fast-valve capillary ion inlet system. This "dual source" approach gives MOMA unprecedented breadth of detection over a wide range of molecular weights and volatilities. Analysis of nonvolatile, higher-molecular weight organics such as carboxylic acids and peptides even in the presence of significant perchlorate concentrations is enabled by the extremely short (~1 ns) pulses of the desorption laser. Use of the ion trap's tandem mass spectrometry mode permits selective focus on key species for isolation and controlled fragmentation, providing structural analysis capabilities. The flight-like engineering test unit (ETU) of the ITMS, now under construction, will be used to verify breadboard performance with high fidelity, while simultaneously supporting the development of analytical scripts and spectral libraries using synthetic and natural Mars analog samples guided by current results from MSL. ETU campaign data will strongly advise the specifics of the calibration applied to the MOMA flight model as well as the science operational procedures during the mission.
NASA Astrophysics Data System (ADS)
Stewart, Elaine M.; Coan, Mary R.; Captain, Janine; Santiago-Bond, Josephine
2016-09-01
In-Situ Resource Utilization (ISRU) is a key NASA initiative to exploit resources at the site of planetary exploration for mission-critical consumables, propellants, and other supplies. The Resource Prospector mission, part of ISRU, is scheduled to launch in 2020 and will include a rover and lander hosting the Regolith and Environment Science and Oxygen and Lunar Volatile Extraction (RESOLVE) payload for extracting and analyzing lunar resources, particularly low molecular weight volatiles for fuel, air, and water. RESOLVE contains the Lunar Advanced Volatile Analysis (LAVA) subsystem with a Gas Chromatograph-Mass Spectrometer (GC-MS). RESOLVE subsystems, including the RP15 rover and LAVA, are in NASA's Engineering Test Unit (ETU) phase to assure that all vital components of the payload are space-flight rated and will perform as expected during the mission. Integration and testing of LAVA mass spectrometry verified reproducibility and accuracy of the candidate MS for detecting nitrogen, oxygen, and carbon dioxide. The RP15 testing comprised volatile analysis of water-doped simulant regolith to enhance integration of the RESOLVE payload with the rover. Multiple tests show the efficacy of the GC to detect 2% and 5% water-doped samples.
Characterization of pesticide exposure in a sample of pregnant women in Ecuador
Handal, Alexis J.; Hund, Lauren; Páez, Maritza; Bear, Samantha; Greenberg, Carolyn; Fenske, Richard A.; Barr, Dana Boyd
2015-01-01
Background Few studies have detailed the prenatal pesticide exposure levels of women employed in or residing near large-scale agricultural industries. This study reports pesticide metabolite levels during and shortly after pregnancy in a pilot study of workers in Ecuador. Methods Urine samples were collected for 16 rose workers and 10 non-agricultural workers enrolled into the study in early pregnancy. We measured six nonspecific organophosphate dialkylphosphate (DAP) pesticide metabolites, two alkylenebis-dithiocarbamate pesticide metabolites (ethylene thiourea [ETU] and propylene thiourea [PTU]), 3,5,6-trichloro-2-pyridinol [TCPy], malathion dicarboxylic acid, and two pyrethroid metabolites (2,2-dimethylcyclopropanecarboxylic acid and 3-phenooxybenzoic acid). Results We collected 141 urine samples (mean: 5.4 per woman). We observed high detection frequencies for five DAP metabolites and ETU, PTU, and TCPy. We report elevated levels of ETU in the entire sample (median 4.24 ng/mL, IQR 2.23, 7.18), suggesting other possible non-occupational pathways of exposure. We found no statistical differences in pesticide levels by current employment status, though the highest pesticide levels were among rose workers. We observed within-woman correlation in TCPy and PTU levels, but not in ETU or DAP levels. Conclusions The present study is the first to characterize prenatal pesticide exposure levels among working women in Ecuador. Limitations include a small sample size and use of a convenience sample. Strengths include a longitudinal design and multiple urine samples per woman. Results provide an initial characterization of prenatal pesticide exposure levels and how these levels vary over pregnancy in a community impacted by agricultural industry and will inform further studies in the region. PMID:26311023
Estimating the future number of cases in the Ebola epidemic--Liberia and Sierra Leone, 2014-2015.
Meltzer, Martin I; Atkins, Charisma Y; Santibanez, Scott; Knust, Barbara; Petersen, Brett W; Ervin, Elizabeth D; Nichol, Stuart T; Damon, Inger K; Washington, Michael L
2014-09-26
The first cases of the current West African epidemic of Ebola virus disease (hereafter referred to as Ebola) were reported on March 22, 2014, with a report of 49 cases in Guinea. By August 31, 2014, a total of 3,685 probable, confirmed, and suspected cases in West Africa had been reported. To aid in planning for additional disease-control efforts, CDC constructed a modeling tool called EbolaResponse to provide estimates of the potential number of future cases. If trends continue without scale-up of effective interventions, by September 30, 2014, Sierra Leone and Liberia will have a total of approximately 8,000 Ebola cases. A potential underreporting correction factor of 2.5 also was calculated. Using this correction factor, the model estimates that approximately 21,000 total cases will have occurred in Liberia and Sierra Leone by September 30, 2014. Reported cases in Liberia are doubling every 15-20 days, and those in Sierra Leone are doubling every 30-40 days. The EbolaResponse modeling tool also was used to estimate how control and prevention interventions can slow and eventually stop the epidemic. In a hypothetical scenario, the epidemic begins to decrease and eventually end if approximately 70% of persons with Ebola are in medical care facilities or Ebola treatment units (ETUs) or, when these settings are at capacity, in a non-ETU setting such that there is a reduced risk for disease transmission (including safe burial when needed). In another hypothetical scenario, every 30-day delay in increasing the percentage of patients in ETUs to 70% was associated with an approximate tripling in the number of daily cases that occur at the peak of the epidemic (however, the epidemic still eventually ends). Officials have developed a plan to rapidly increase ETU capacities and also are developing innovative methods that can be quickly scaled up to isolate patients in non-ETU settings in a way that can help disrupt Ebola transmission in communities. The U.S. government and international organizations recently announced commitments to support these measures. As these measures are rapidly implemented and sustained, the higher projections presented in this report become very unlikely.
Shao, Xiaoping; Ren, Weizheng; Zhou, Feihu
2017-01-24
In order to evaluate the clinical characteristics of confirmed Ebola Virus Disease (EVD) patients admitted to the China Ebola Treatment Unit (China ETU) between January 2015 and March 2015, we retrospectively analyzed clinical symptoms, treatment, and epidemiologic features of 5 patients with confirmed EVD, and reviewed the relevant medical literature. Of these, 3 patients survived, and 2 died. The time interval from the onset of symptoms to the negative PCR test for Ebola virus in the 3 survivors was 14-18 days. All survivors reported direct contact with confirmed EVD patients up to 21 days prior to admission. All patients developed a fever, fatigue, and anorexia. Fever was generally the first symptom to develop, followed by a gastrointestinal phase characterized by vomiting/nausea (3 cases, 60%), diarrhea (3 cases), and abdominal pain (4 cases, 80%). Three patients (60%) reported joint pain, muscle pain, and conjunctival hemorrhage, respectively, and 2 patients (40%) developed a headache. We concluded that strict isolation and interruption of the route of transmission were required for suspected or confirmed EVD patients. The main treatment strategies were supportive care, maintenance of blood volume and electrolyte balance, and the prevention of complications.
Lu, Dawei; Mao, Chenchen; Cho, Suehyun K.; Ahn, Sungmo; Park, Wounjhang
2016-01-01
Energy transfer upconversion (ETU) is known to be the most efficient frequency upconversion mechanism. Surface plasmon can further enhance the upconversion process, opening doors to many applications. However, ETU is a complex process involving competing transitions between multiple energy levels and it has been difficult to precisely determine the enhancement mechanisms. In this paper, we report a systematic study on the dynamics of the ETU process in NaYF4:Yb3+,Er3+ nanoparticles deposited on plasmonic nanograting structure. From the transient near-infrared photoluminescence under various excitation power densities, we observed faster energy transfer rates under stronger excitation conditions until it reached saturation where the highest internal upconversion efficiency was achieved. The experimental data were analyzed using the complete set of rate equations. The internal upconversion efficiency was found to be 56% and 36%, respectively, with and without the plasmonic nanograting. We also analyzed the transient green emission and found that it is determined by the infrared transition rate. To our knowledge, this is the first report of experimentally measured internal upconversion efficiency in plasmon enhanced upconversion material. Our work decouples the internal upconversion efficiency from the overall upconverted luminescence efficiency, allowing more targeted engineering for efficiency improvement. PMID:26739230
NASA Technical Reports Server (NTRS)
Avanov, Levon A.; Gliese, Ulrik; Mariano, Albert; Tucker, Corey; Barrie, Alexander; Chornay, Dennis J.; Pollock, Craig James; Kujawski, Joseph T.; Collinson, Glyn A.; Nguyen, Quang T.;
2011-01-01
The Magnetospheric Multiscale mission (MMS) is designed to study fundamental phenomena in space plasma physics such as a magnetic reconnection. The mission consists of four spacecraft, equipped with identical scientific payloads, allowing for the first measurements of fast dynamics in the critical electron diffusion region where magnetic reconnection occurs and charged particles are demagnetized. The MMS orbit is optimized to ensure the spacecraft spend extended periods of time in locations where reconnection is known to occur: at the dayside magnetopause and in the magnetotail. In order to resolve fine structures of the three dimensional electron distributions in the diffusion region (reconnection site), the Fast Plasma Investigation's (FPI) Dual Electron Spectrometer (DES) is designed to measure three dimensional electron velocity distributions with an extremely high time resolution of 30 ms. In order to achieve this unprecedented sampling rate, four dual spectrometers, each sampling 180 x 45 degree sections of the sky, are installed on each spacecraft. We present results of the comprehensive tests performed on the DES Engineering & Test Unit (ETU). This includes main parameters of the spectrometer such as energy resolution, angular acceptance, and geometric factor along with their variations over the 16 pixels spanning the 180-degree tophat Electro Static Analyzer (ESA) field of view and over the energy of the test beam. A newly developed method for precisely defining the operational space of the instrument is presented as well. This allows optimization of the trade-off between pixel to pixel crosstalk and uniformity of the main spectrometer parameters.
Mora, Ana María; Córdoba, Leonel; Cano, Juan Camilo; Hernandez-Bonilla, David; Pardo, Larissa; Schnaas, Lourdes; Smith, Donald R; Menezes-Filho, José A; Mergler, Donna; Lindh, Christian H; Eskenazi, Brenda; van Wendel de Joode, Berna
2018-05-01
Although growing evidence suggests that early-life excess manganese (Mn) impairs neurodevelopment, data on the neurodevelopmental effects of mancozeb, a fungicide containing Mn, and its main metabolite ethylenethiourea (ETU) are limited. We examined whether prenatal mancozeb exposure and excess Mn were associated with neurodevelopment in 355 1-y-old infants living near banana plantations with frequent aerial mancozeb spraying in Costa Rica. We measured urinary ETU, hair Mn, and blood Mn concentrations in samples collected 1-3 times during pregnancy from mothers enrolled in the Infants' Environmental Health (ISA) study. We then assessed neurodevelopment in their 1-y-old infants using the Bayley Scales of Infant and Toddler Development, 3rd edition (BSID-III). We estimated exposure-outcome associations using linear regression models adjusted for maternal education, parity, gestational age at birth, child age, Home Observation for Measurement of the Environment score, and location of neurodevelopmental assessment. Median (P25-P75) urinary ETU, hair Mn, and blood Mn measured during pregnancy were 3.3 μg/L (2.4-4.9; specific gravity-corrected), 1.7 μg/g (0.9-4.1), and 24.0 μg/L (20.3-28.0), respectively. Among girls, higher ETU was associated with lower social-emotional scores [β per 10-fold increase=-7.4 points (95% CI: -15.2, 0.4)], whereas higher hair Mn was associated with lower cognitive scores [-3.0 (-6.1, 0.1)]. Among boys, higher hair Mn was associated with lower social-emotional scores [-4.6 (-8.5, -0.8)]. We observed null associations for blood Mn, language, and motor outcomes. Our findings indicate that maternal exposure to mancozeb and excess Mn during pregnancy may have adverse and sex-specific effects on infant neurodevelopment. https://doi.org/10.1289/EHP1955.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diaz, Aaron A.; Chamberlin, Clyde E.; Edwards, Matthew K.
This section of the Joint summary technical letter report (TLR) describes work conducted at the Pacific Northwest National Laboratory (PNNL) during FY 2016 (FY16) on the under-sodium viewing (USV) PNNL project 58745, work package AT-16PN230102. This section of the TLR satisfies PNNL’s M3AT-16PN2301025 milestone and is focused on summarizing the design, development, and evaluation of two different phased-array ultrasonic testing (PA-UT) probe designs—a two-dimensional (2D) matrix phased-array probe, and two one-dimensional (1D) linear array probes, referred to as serial number 4 (SN4) engineering test units (ETUs). The 2D probe is a pulse-echo (PE), 32×2, 64-element matrix phased-array ETU. The 1Dmore » probes are 32×1 element linear array ETUs. This TLR also provides the results from a performance demonstration (PD) of in-sodium target detection trials at 260°C using both probe designs. This effort continues the iterative evolution supporting the longer term goal of producing and demonstrating a pre-manufacturing prototype ultrasonic probe that possesses the fundamental performance characteristics necessary to enable the development of a high-temperature sodium-cooled fast reactor (SFR) inspection system for in-sodium detection and imaging.« less
Deleterious Effects From Occupational Exposure to Ethylene Thiourea in Pregnant Women.
Mutic, Abby D; Baker, Brenda J; McCauley, Linda A
2017-12-01
Human exposure to endocrine disrupting chemicals (EDCs) has become common as a result of widespread application of these chemicals to the food supply, environmental contamination, and occupational exposures (Caserta et al., 2011). However, relatively little is known about the effects of EDCs such as ethylene thiourea (ETU) in developing fetuses and the lasting implications of this disruption on human development from birth through adulthood. Of highest concern are chronic, low-dose exposures among industrial and agricultural workers. Current knowledge regarding the significance of endocrine thyroid signaling on normal human development raises serious concerns about the possible deleterious effects of EDCs in the developing fetus, children, and mature adults. Occupational health nurses are critical in identifying women and families at increased risk of ETU exposure and mitigating early exposures in pregnancy.
Sharma, Aditya; Heijenberg, Nico; Peter, Clement; Bolongei, Josephus; Reeder, Bruce; Alpha, Tamba; Sterk, Esther; Robert, Hugues; Kurth, Andreas; Cannas, Angela; Bocquin, Anne; Strecker, Thomas; Logue, Christopher; Di Caro, Antonino; Pottage, Thomas; Yue, Constanze; Stoecker, Kilian; Wölfel, Roman; Gabriel, Martin; Günther, Stephan; Damon, Inger
2014-11-21
Lofa County has one of the highest cumulative incidences of Ebola virus disease (Ebola) in Liberia. Recent situation reports from the Liberian Ministry of Health and Social Welfare (MoHSW) have indicated a decrease in new cases of Ebola in Lofa County. In October 2014, the Liberian MoHSW requested the assistance of CDC to further characterize recent trends in Ebola in Lofa County. Data collected during June 8-November 1, 2014 from three sources were analyzed: 1) aggregate data for newly reported cases, 2) case-based data for persons admitted to the dedicated Ebola treatment unit (ETU) for the county, and 3) test results for community decedents evaluated for Ebola. Trends from all three sources suggest that transmission of Ebola virus decreased as early as August 17, 2014, following rapid scale-up of response activities in Lofa County after a resurgence of Ebola in early June 2014. The comprehensive response strategy developed with participation from the local population in Lofa County might serve as a model to implement in other affected areas to accelerate control of Ebola.
Elimination of Ebola Virus Transmission in Liberia - September 3, 2015.
Bawo, Luke; Fallah, Mosoka; Kateh, Francis; Nagbe, Thomas; Clement, Peter; Gasasira, Alex; Mahmoud, Nuha; Musa, Emmanuel; Lo, Terrence Q; Pillai, Satish K; Seeman, Sara; Sunshine, Brittany J; Weidle, Paul J; Nyensweh, Tolbert
2015-09-11
Following 42 days since the last Ebola virus disease (Ebola) patient was discharged from a Liberian Ebola treatment unit (ETU), September 3, 2015, marks the second time in a 4-month period that the World Health Organization (WHO) has declared Liberia free of Ebola virus transmission (1). The first confirmed Ebola cases in West Africa were identified in southeastern Guinea on March 23, 2014, and within 1 week, cases were identified and confirmed in Liberia (1). Since then, Liberia has reported 5,036 confirmed and probable Ebola cases and 4,808 Ebola-related deaths. The epidemic in Liberia peaked in late summer and early fall of 2014, when more than 200 confirmed and probable cases were reported each week .
Photoluminescence of Er-doped silicon-rich oxide thin films with high Al concentrations
NASA Astrophysics Data System (ADS)
Rozo, Carlos; Fonseca, Luis F.; Jaque, Daniel; García Solé, José
Er-doped silicon-rich oxide (SRO) thin films co-doped with Al in high concentrations were prepared by sputtering. Some films were deposited using a substrate heater (150 °C
Design and Construction of a Hydroturbine Test Facility
NASA Astrophysics Data System (ADS)
Ayli, Ece; Kavurmaci, Berat; Cetinturk, Huseyin; Kaplan, Alper; Celebioglu, Kutay; Aradag, Selin; Tascioglu, Yigit; ETU Hydro Research Center Team
2014-11-01
Hydropower is one of the clean, renewable, flexible and efficient energy resources. Most of the developing countries invest on this cost-effective energy source. Hydroturbines for hydroelectric power plants are tailor-made. Each turbine is designed and constructed according to the properties, namely the head and flow rate values of the specific water source. Therefore, a center (ETU Hydro-Center for Hydro Energy Research) for the design, manufacturing and performance tests of hydraulic turbines is established at TOBB University of Economics and Technology to promote research in this area. CFD aided hydraulic and structural design, geometry optimization, manufacturing and performance tests of hydraulic turbines are the areas of expertise of this center. In this paper, technical details of the design and construction of this one of a kind test facility in Turkey, is explained. All the necessary standards of IEC (International Electrotechnical Commission) are met since the test facility will act as a certificated test center for hydraulic turbines.
Purpura, Lawrence J; Soka, Moses; Baller, April; White, Stephen; Rogers, Emerson; Choi, Mary J; Mahmoud, Nuha; Wasunna, Christine; Massaquoi, Moses; Vanderende, Kristin; Kollie, Jomah; Dweh, Straker; Bemah, Philip; Christie, Athalia; Ladele, Victor; Subah, Onyekachi; Pillai, Satish; Mugisha, Margaret; Kpaka, Jonathan; Nichol, Stuart; Ströher, Ute; Abad, Neetu; Mettee-Zarecki, Shauna; Bailey, Jeff A; Rollin, Pierre; Marston, Barbara; Nyenswah, Tolbert; Gasasira, Alex; Knust, Barbara; Williams, Desmond
2016-09-16
According to World Health Organization (WHO) data, the Ebola virus disease (Ebola) outbreak that began in West Africa in 2014 has resulted in 28,603 cases and 11,301 deaths (1). In March 2015, epidemiologic investigation and genetic sequencing in Liberia implicated sexual transmission from a male Ebola survivor, with Ebola virus detected by reverse transcription-polymerase chain reaction (RT-PCR) 199 days after symptom onset (2,3), far exceeding the 101 days reported from an earlier Ebola outbreak (4). In response, WHO released interim guidelines recommending that all male survivors, in addition to receiving condoms and sexual risk reduction counseling at discharge from an Ebola treatment unit (ETU), be offered semen testing for Ebola virus RNA by RT-PCR 3 months after disease onset, and every month thereafter until two consecutive semen specimens collected at least 1 week apart test negative for Ebola virus RNA (5). Male Ebola survivors should also receive counseling to promote safe sexual practices until their semen twice tests negative. When these recommendations were released, testing of semen was not widely available in Liberia. Challenges in establishing and operating the first nationwide semen testing and counseling program for male Ebola survivors included securing sufficient resources for the program, managing a public health semen testing program in the context of ongoing research studies that were also collecting and screening semen, identification of adequate numbers of trained counselors and appropriate health communication messages for the program, overcoming Ebola survivor-associated stigma, identification and recruitment of male Ebola survivors, and operation of mobile teams.
Blackley, David J; Lindblade, Kim A; Kateh, Francis; Broyles, Laura N; Westercamp, Matthew; Neatherlin, John C; Pillai, Satish K; Tucker, Anthony; Mott, Joshua A; Walke, Henry; Nyenswah, Tolbert
2015-02-27
As late as September 14, 2014, Liberia's Gbarpolu County had reported zero cases of Ebola virus disease (Ebola). On October 25, the Bong County Health Team, a local health department in the Liberian Ministry of Health and Social Welfare (MOHSW), received confirmation of Ebola in a man who had recently left Geleyansiesu, a remote village of approximately 800 residents, after his wife and daughter had died of illnesses consistent with Ebola. MOHSW requested assistance from CDC, the World Health Organization, and other international partners to investigate and confirm the outbreak in Geleyansiesu and begin interventions to interrupt transmission. A total of 22 cases were identified, of which 18 (82%) were laboratory confirmed by real-time polymerase chain reaction. There were 16 deaths (case-fatality rate = 73%). Without road access to or direct telecommunications with the village, interventions had to be tailored to the local context. Public health interventions included 1) education of the community about Ebola, transmission of the virus, signs and symptoms, the importance of isolating ill patients from family members, and the potential benefits of early diagnosis and treatment; 2) establishment of mechanisms to alert health authorities of possibly infected persons leaving the village to facilitate safe transport to the closest Ebola treatment unit (ETU); 3) case investigation, contact tracing, and monitoring of contacts; 4) training in hygienic burial of dead bodies; 5) active case finding and diagnosis; and 6) isolation and limited no-touch treatment in the village of patients unwilling or unable to seek care at an ETU. The findings of this investigation could inform interventions aimed at controlling focal outbreaks in difficult-to-reach communities, which has been identified as an important component of the effort to eliminate Ebola from Liberia.
Water-hyacinth production primary and advanced treatment of wastewater. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwegler, B.R. Jr.
1983-01-01
A prototype water hyacinth wastewater treatment system has been in operation for two years at Walt Disney World, near Orlando, Florida. Typically, the hyacinth system removes 80-90% total suspended solids and B.O.D. from the influent stream. Major impacts on water quality exiting the system are: seasonal variations in solar radiation, air and water temperature; operational problems, particularly harvesting equipment breakdown, and retention time in the ponds. Phosphorus and nitrogen removal show a strong seasonal dependence, with removal rates varying from 0.08 to 1.11 g/m/sup 2//day for N and from 0.05 to 0.29 g/m/sup 2//day for P. Nitrogen removal rates showmore » a strong dependence on retention times, with a retention time of 5 days appearing to be a critical limit for the establishment of an active population of denitrifying bacteria. Hyacinth biomass productivity of the system was approximately 66.7 dry metric tons per hectare year (30 dry tons/acre year) during the second year of operation. An Experimental Test Unit (ETU) for anaerobic digestion of hyacinths to methane will be installed by late 1983.« less
76 FR 18906 - Mancozeb; Pesticide Tolerances
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-06
... from mancozeb and ETU in food as follows: i. Acute exposure. Quantitative acute dietary exposure and.... Cancer. EPA determines whether quantitative cancer exposure and risk assessments are appropriate for a... quantitative cancer risk assessment is appropriate, cancer risk may be quantified using a linear or nonlinear...
Theoretical evaluation of a continues-wave Ho3+:BaY2F8 laser with mid-infrared emission
NASA Astrophysics Data System (ADS)
Rong, Kepeng; Cai, He; An, Guofei; Han, Juhong; Yu, Hang; Wang, Shunyan; Yu, Qiang; Wu, Peng; Zhang, Wei; Wang, Hongyuan; Wang, You
2018-01-01
In this paper, we build a theoretical model to study a continues-wave (CW) Ho3+:BaY2F8 laser by considering both energy transfer up-conversion (ETU) and cross relaxation (CR) processes. The influences of the pump power, reflectance of an output coupler (OC), and crystal length on the output features are systematically analyzed for an end-pumped configuration, respectively. We also investigate how the processes of ETU and CR in the energy-level system affect the output of a Ho3+:BaY2F8 laser by use of the kinetic evaluation. The simulation results show that the optical-to-optical efficiency can be promoted by adjusting the parameters such as the reflectance of an output coupler, crystal length, and pump power. It has been theoretically demonstrated that the threshold of a Ho3+:BaY2F8 laser is very high for the lasing operation in a CW mode.
Lunar Advanced Volatile Analysis Subsystem: Pressure Transducer Trade Study
NASA Technical Reports Server (NTRS)
Kang, Edward Shinuk
2017-01-01
In Situ Resource Utilization (ISRU) is a key factor in paving the way for the future of human space exploration. The ability to harvest resources on foreign astronomical objects to produce consumables and propellant offers potential reduction in mission cost and risk. Through previous missions, the existence of water ice at the poles of the moon has been identified, however the feasibility of water extraction for resources remains unanswered. The Resource Prospector (RP) mission is currently in development to provide ground truth, and will enable us to characterize the distribution of water at one of the lunar poles. Regolith & Environment Science and Oxygen & Lunar Volatile Extraction (RESOLVE) is the primary payload on RP that will be used in conjunction with a rover. RESOLVE contains multiple instruments for systematically identifying the presence of water. The main process involves the use of two systems within RESOLVE: the Oxygen Volatile Extraction Node (OVEN) and Lunar Advanced Volatile Analysis (LAVA). Within the LAVA subsystem, there are multiple calculations that depend on accurate pressure readings. One of the most important instances where pressure transducers (PT) are used is for calculating the number of moles in a gas transfer from the OVEN subsystem. As a critical component of the main process, a mixture of custom and commercial off the shelf (COTS) PTs are currently being tested in the expected operating environment to eventually down select an option for integrated testing in the LAVA engineering test unit (ETU).
Method of Generating Transient Equivalent Sink and Test Target Temperatures for Swift BAT
NASA Technical Reports Server (NTRS)
Choi, Michael K.
2004-01-01
The NASA Swift mission has a 600-km altitude and a 22 degrees maximum inclination. The sun angle varies from 45 degrees to 180 degrees in normal operation. As a result, environmental heat fluxes absorbed by the Burst Alert Telescope (BAT) radiator and loop heat pipe (LHP) compensation chambers (CCs) vary transiently. Therefore the equivalent sink temperatures for the radiator and CCs varies transiently. In thermal performance verification testing in vacuum, the radiator and CCs radiated heat to sink targets. This paper presents an analytical technique for generating orbit transient equivalent sink temperatures and a technique for generating transient sink target temperatures for the radiator and LHP CCs. Using these techniques, transient target temperatures for the radiator and LHP CCs were generated for three thermal environmental cases: worst hot case, worst cold case, and cooldown and warmup between worst hot case in sunlight and worst cold case in the eclipse, and three different heat transport values: 128 W, 255 W, and 382 W. The 128 W case assumed that the two LHPs transport 255 W equally to the radiator. The 255 W case assumed that one LHP fails so that the remaining LHP transports all the waste heat from the detector array to the radiator. The 382 W case assumed that one LHP fails so that the remaining LHP transports all the waste heat from the detector array to the radiator, and has a 50% design margin. All these transient target temperatures were successfully implemented in the engineering test unit (ETU) LHP and flight LHP thermal performance verification tests in vacuum.
NASA Astrophysics Data System (ADS)
Rahmim, Arman; Schmidtlein, C. Ross; Jackson, Andrew; Sheikhbahaei, Sara; Marcus, Charles; Ashrafinia, Saeed; Soltani, Madjid; Subramaniam, Rathan M.
2016-01-01
Oncologic PET images provide valuable information that can enable enhanced prognosis of disease. Nonetheless, such information is simplified significantly in routine clinical assessment to meet workflow constraints. Examples of typical FDG PET metrics include: (i) SUVmax, (2) total lesion glycolysis (TLG), and (3) metabolic tumor volume (MTV). We have derived and implemented a novel metric for tumor quantification, inspired in essence by a model of generalized equivalent uniform dose as used in radiation therapy. The proposed metric, denoted generalized effective total uptake (gETU), is attractive as it encompasses the abovementioned commonly invoked metrics, and generalizes them, for both homogeneous and heterogeneous tumors, using a single parameter a. We evaluated this new metric for improved overall survival (OS) prediction on two different baseline FDG PET/CT datasets: (a) 113 patients with squamous cell cancer of the oropharynx, and (b) 72 patients with locally advanced pancreatic adenocarcinoma. Kaplan-Meier survival analysis was performed, where the subjects were subdivided into two groups using the median threshold, from which the hazard ratios (HR) were computed in Cox proportional hazards regression. For the oropharyngeal cancer dataset, MTV, TLG, SUVmax, SUVmean and SUVpeak produced HR values of 1.86, 3.02, 1.34, 1.36 and 1.62, while the proposed gETU metric for a = 0.25 (greater emphasis on volume information) enabled significantly enhanced OS prediction with HR = 3.94. For the pancreatic cancer dataset, MTV, TLG, SUVmax, SUVmean and SUVpeak resulted in HR values of 1.05, 1.25, 1.42, 1.45 and 1.52, while gETU at a = 3.2 (greater emphasis on SUV information) arrived at an improved HR value of 1.61. Overall, the proposed methodology allows placement of differing degrees of emphasis on tumor volume versus uptake for different types of tumors to enable enhanced clinical outcome prediction.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-31
...-Regulatory Organizations; The NASDAQ Stock Market LLC; Notice of Filing and Immediate Effectiveness of...\\ notice is hereby given that on December 17, 2012, The NASDAQ Stock Market LLC (``NASDAQ'' or the... Equity Technical Update 2012-31 ( http://www.nasdaqtrader.com/TraderNews.aspx?id=ETU2012-31 ). Because...
Li, Li; Wan, Changli; Ding, Ru; Liu, Yi; Chen, Jue; Wu, Zonggui; Liang, Chun; He, Zhiqing; Li, Chengzhong
2015-09-26
Ebola virus outbreak in West Africa not only triggered a grave public health crisis, but also exerted and induced huge mental distress on medical staff, which would negatively influence epidemic control and social rebuilt furthermore. We chose the local medical staff working at the China Ebola Treatment Unit (ETU) to explore the severity of potential mental distress and involved potential causes. A descriptive study using the Symptom Check List 90 - Revised (SCL90-R) questionnaire to assess psychological health status was conducted among 52 Liberian medical staff. Global indices, including Global Severity Index (GSI), Positive Symptom Total (PST) and Positive Symptom Distress Index (PSDI), and nine subscales based on 90 inquiry items were compared among gender, work duty and other subgroups. Data were analyzed using Graphpad Prism and SPSS software. Mental distress among participants was not very serious; only PSDI, paranoid ideation and interpersonal sensitivity numerically increased relative to changes in other categories. While male medics and those responsible for cleaning and disinfection showed significant increases in scores for psychological dimensions, such as obsessive-compulsive, anxiety, phobic anxiety, interpersonal sensitivity, paranoid ideation and positive symptom total. Data of this study implies that the psychological health status of medical staff within the special social environment of an Ebola treatment unit should warrant more attention.
van Wendel de Joode, Berna; Barbeau, Benoit; Bouchard, Maryse F; Mora, Ana María; Skytt, Åsa; Córdoba, Leonel; Quesada, Rosario; Lundh, Thomas; Lindh, Christian H; Mergler, Donna
2016-08-01
Elevated manganese (Mn) in drinking water has been reported worldwide. While, naturally occurring Mn in groundwater is generally the major source, anthropogenic contamination by Mn-containing fungicides such as mancozeb may also occur. The main objective of this study was to examine factors associated with Mn and ethylenethiourea (ETU), a degradation product of mancozeb, in drinking water samples from villages situated near banana plantations with aerial spraying of mancozeb. Drinking water samples (n = 126) were obtained from 124 homes of women participating in the Infants' Environmental Health Study (ISA, for its acronym in Spanish), living nearby large-scale banana plantations. Concentrations of Mn, iron (Fe), arsenic (As), lead (Pb), cadmium (Cd) and ethylenethiourea (ETU), a degradation product of mancozeb, were measured in water samples. Only six percent of samples had detectable ETU concentrations (limit of detection (LOD) = 0.15 μg/L), whereas 94% of the samples had detectable Mn (LOD = 0.05 μg/L). Mn concentrations were higher than 100 and 500 μg/L in 22% and 7% of the samples, respectively. Mn was highest in samples from private and banana farm wells. Distance from a banana plantation was inversely associated with Mn concentrations, with a 61.5% decrease (95% CI: -97.0, -26.0) in Mn concentrations for each km increase in distance. Mn concentrations in water transported with trucks from one village to another were almost 1000 times higher than Mn in water obtained from taps in houses supplied by the same well but not transported, indicating environmental Mn contamination. Elevated Mn in drinking water may be partly explained by aerial spraying of mancozeb; however, naturally occurring Mn in groundwater, and intensive agriculture may also contribute. Drinking water risk assessment for mancozeb should consider Mn as a health hazard. The findings of this study evidence the need for health-based World Health Organization (WHO) guidelines on Mn in drinking water. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Henwood, Patricia C; Bebell, Lisa M; Roshania, Reshma; Wolfman, Vanessa; Mallow, Michaela; Kalyanpur, Anushka; Levine, Adam C
2017-07-15
Reliable data are lacking on pregnancy outcomes during Ebola virus disease (EVD) epidemics. We aimed to characterize symptoms and outcomes among pregnant women admitted to Ebola treatment units (ETUs) with suspected and confirmed EVD to better inform obstetric management. We analyzed a retrospective cohort of reproductive-aged women presenting to 5 West African ETUs from September 2014 to September 2015. We compared clinical symptoms, risk of EVD diagnosis, and mortality between pregnant and nonpregnant women. Of 729 reproductive-aged women admitted to study ETUs, 44 (6%) reported pregnancy. Thirteen of 44 pregnant women (30%) tested EVD positive; 6 of 13 (46%) died. Pregnant women were less likely than nonpregnant women to report anorexia, asthenia, diarrhea, fever, myalgias/arthralgias, nausea, or vomiting (P < .05) at admission. Pregnant women with suspected EVD had the same risk, however, of laboratory-confirmed EVD (30% vs 24%, P = .38). While pregnant women with confirmed EVD had similar Ebola viral loads on presentation to nonpregnant women, as measured by initial cycle threshold (26.4 vs 23.2, P = .16), they were less likely to have myalgias/arthralgias (P< .001) and vomiting (P = .02). Both all-cause mortality (14% vs 19%, P = .39) and EVD-specific mortality (46% vs 54%, P = .60) were not significantly different between pregnant and nonpregnant women. Two neonates born live in the ETU died within 8 days. We find no evidence to support a difference in the risk of death between pregnant women with suspected or confirmed EVD compared to nonpregnant women. Limited data suggest poor fetal and neonatal outcomes in EVD-affected pregnancies. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.
Shantha, Jessica G; Crozier, Ian; Hayek, Brent R; Bruce, Beau B; Gargu, Catherine; Brown, Jerry; Fankhauser, John; Yeh, Steven
2017-02-01
To describe the ocular findings, visual impairment, and association of structural complications of uveitis with visual impairment in a cohort of survivors of Ebola virus disease (EVD) in Monrovia, Liberia. Retrospective, uncontrolled, cross-sectional study. Survivors of EVD who were evaluated in an ophthalmology clinic at Eternal Love Winning Africa (ELWA) Hospital in Monrovia, Liberia. A cohort of EVD survivors who underwent baseline ophthalmic evaluation at ELWA Hospital were retrospectively reviewed for demographic information, length of Ebola treatment unit (ETU) stay, visual acuity (VA), and ophthalmic examination findings. For patients with uveitis, disease activity (active vs. inactive) and grade of inflammation were recorded according to Standardization of Uveitis Nomenclature criteria. The level of VA impairment was categorized according to World Health Organization classification for VA impairment as follows: normal/mild, VA 20/70 or better; moderate, VA 20/70-20/200; severe, VA 20/200-20/400; blindness, VA <20/400. Visual acuity, length of ETU stay, and structural complications were compared between EVD survivors with and without uveitis. Structural complications associated with moderate VA impairment or poorer were analyzed. Frequency of ocular complications including uveitis and optic neuropathy in EVD survivors, level of VA impairment in EVD survivors with uveitis, and structural complications associated with VA impairment in EVD survivors. A total of 96 survivors of EVD were examined. A total of 21 patients developed an EVD-associated uveitis, and 3 patients developed an EVD-associated optic neuropathy. Visual acuity was blind (VA >20/400) in 38.5% of eyes with uveitis. Anatomic subtypes of uveitis included anterior, posterior, and panuveitis in 2, 13, and 6 patients, respectively. Examination findings associated with at least moderate visual impairment by World Health Organization criteria (VA <20/70) included keratic precipitates (P < 0.002), posterior synechiae (P < 0.002), vitritis (P < 0.005), and chorioretinal scars (P < 0.02). Survivors of EVD are at risk for uveitis, which may lead to secondary structural complications, visual impairment, and blindness. Eye care resources should be mobilized for EVD survivors in West Africa because of the frequency of this spectrum of disease complication and its potential for severe VA impairment and blindness. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Forrester, Joseph D; Hunter, Jennifer C; Pillai, Satish K; Arwady, M Allison; Ayscue, Patrick; Matanock, Almea; Monroe, Ben; Schafer, Ilana J; Nyenswah, Tolbert G; De Cock, Kevin M
2014-10-17
The ongoing Ebola virus disease (Ebola) epidemic in West Africa, like previous Ebola outbreaks, has been characterized by amplification in health care settings and increased risk for health care workers (HCWs), who often do not have access to appropriate personal protective equipment. In many locations, Ebola treatment units (ETUs) have been established to optimize care of patients with Ebola while maintaining infection control procedures to prevent transmission of Ebola virus. These ETUs are considered essential to containment of the epidemic. In July 2014, CDC assisted the Ministry of Health and Social Welfare of Liberia in investigating a cluster of five Ebola cases among HCWs who became ill while working in an ETU, an adjacent general hospital, or both. No common source of exposure or chain of transmission was identified. However, multiple opportunities existed for transmission of Ebola virus to HCWs, including exposure to patients with undetected Ebola in the hospital, inadequate use of personal protective equipment during cleaning and disinfection of environmental surfaces in the hospital, and potential transmission from an ill HCW to another HCW. No evidence was found of a previously unrecognized mode of transmission. Prevention recommendations included reinforcement of existing infection control guidance for both ETUs and general medical care settings, including measures to prevent cross-transmission in co-located facilities.
Controlling the last known cluster of Ebola virus disease - Liberia, January-February 2015.
Nyenswah, Tolbert; Fallah, Mosoka; Sieh, Sonpon; Kollie, Karsor; Badio, Moses; Gray, Alvin; Dilah, Priscilla; Shannon, Marnijina; Duwor, Stanley; Ihekweazu, Chikwe; Cordier-Lassalle, Thierry; Cordier-Lasalle, Thierry; Shinde, Shivam A; Hamblion, Esther; Davies-Wayne, Gloria; Ratnesh, Murugan; Dye, Christopher; Yoder, Jonathan S; McElroy, Peter; Hoots, Brooke; Christie, Athalia; Vertefeuille, John; Olsen, Sonja J; Laney, A Scott; Neal, Joyce J; Yaemsiri, Sirin; Navin, Thomas R; Coulter, Stewart; Pordell, Paran; Lo, Terrence; Kinkade, Carl; Mahoney, Frank
2015-05-15
As one of the three West African countries highly affected by the 2014-2015 Ebola virus disease (Ebola) epidemic, Liberia reported approximately 10,000 cases. The Ebola epidemic in Liberia was marked by intense urban transmission, multiple community outbreaks with source cases occurring in patients coming from the urban areas, and outbreaks in health care facilities (HCFs). This report, based on data from routine case investigations and contact tracing, describes efforts to stop the last known chain of Ebola transmission in Liberia. The index patient became ill on December 29, 2014, and the last of 21 associated cases was in a patient admitted into an Ebola treatment unit (ETU) on February 18, 2015. The chain of transmission was stopped because of early detection of new cases; identification, monitoring, and support of contacts in acceptable settings; effective triage within the health care system; and rapid isolation of symptomatic contacts. In addition, a "sector" approach, which divided Montserrado County into geographic units, facilitated the ability of response teams to rapidly respond to community needs. In the final stages of the outbreak, intensive coordination among partners and engagement of community leaders were needed to stop transmission in densely populated Montserrado County. A companion report describes the efforts to enhance infection prevention and control efforts in HCFs. After February 19, no additional clusters of Ebola cases have been detected in Liberia. On May 9, the World Health Organization declared the end of the Ebola outbreak in Liberia.
End-To-END Performance of the Future MOMA Instrument Aboard the ExoMars Mission
NASA Astrophysics Data System (ADS)
Pinnick, V. T.; Buch, A.; Szopa, C.; Grand, N.; Danell, R.; Grubisic, A.; van Amerom, F. H. W.; Glavin, D. P.; Freissinet, C.; Coll, P. J.; Stalport, F.; Humeau, O.; Arevalo, R. D., Jr.; Brinckerhoff, W. B.; Steininger, H.; Goesmann, F.; Raulin, F.; Mahaffy, P. R.
2015-12-01
Following the SAM experiment aboard the Curiosity rover, the Mars Organic Molecule Analyzer (MOMA) experiment aboard the 2018 ExoMars mission will be the continuation of the search for organic matter on the Mars surface. One advancement with the ExoMars mission is that the sample will be extracted as deep as 2 meters below the Martian surface to minimize effects of radiation and oxidation on organic materials. To analyze the wide range of organic composition (volatile and non-volatile compounds) of the Martian soil, MOMA is equipped with a dual ion source ion trap mass spectrometer utilizing UV laser desorption / ionization (LDI) and pyrolysis gas chromatography (pyr-GC). In order to analyze refractory organic compounds and chiral molecules during GC-ITMS analysis, samples may be submitted to a derivatization process, consisting of the reaction of the sample components with specific reactants (MTBSTFA [1], DMF-DMA [2] or TMAH [3]). Previous experimental reports have focused on coupling campaigns between the breadboard versions of the GC, provided by the French team (LISA, LATMOS, CentraleSupelec), and the MS, provided by the US team (NASA-GSFC). This work focuses on the performance verification and optimization of the GC-ITMS experiment using the Engineering Test Unit (ETU) models which are representative of the form, fit and function of the flight instrument including a flight-like pyrolysis oven and tapping station providing by the German team (MPS). The results obtained demonstrate the current status of the end-to-end performance of the gas chromatography-mass spectrometry mode of operation. References: [1] Buch, A. et al. (2009) J Chrom. A, 43, 143-151. [2] Freissinet et al. (2011) J Chrom A, 1306, 59-71. [3] Geffroy-Rodier, C. et al. (2009) JAAP, 85, 454-459.
2015-07-14
2.4 ms [24] for Er: KPb2Cl5 and ~ 1.9 ms [13] for Er: KPb2Br5). This feature is indicative of nonradiative ETU process taking place [16...such as YAG as nonradiative decay rates are smaller in chloride and bromide based hosts. Using equation (5) the microparameters for the infrared...is present which also contributes to the effective decay transient. Similar to Pr3+ in the halide hosts KPb2Cl5 and 25 KPb2Br5 nonradiative decay
Teratogenic Potential of Ethylene Thiourea (ETU), A Positive Control in Sprague-Dawley Rats.
1987-10-01
fetuses examined 308 215 Anomalies Exencephaly 219 71 Hydrocephaly 123 40 Domed cranium 98 32 1 0 Flat cranium 62 20 Pointed cranium 2 1 N. Cleft palate ...Brachygnathia 27 18 Prognathism 1 1 Agnathia I l Lobed tongue I 1 Protruding tongue 1O 7 Cleft palate 14 9 Cleft nose and palate 1 1 Abnormal turblnates 1 I...mandible 6 4 1 1 Short mandible 13 8 Cleft palate 26 16 Kyphosis 70 44 Scoliosis 5 3 Missing lumbar vertebrae 3 2 Missing ribs 4 2 Branched or fused ribs 42
Waxman, Matthew; Aluisio, Adam R; Rege, Soham; Levine, Adam C
2017-06-01
The 2014-15 Ebola virus disease (EVD) epidemic strained health systems in west Africa already overburdened with other diseases, including malaria. Because EVD and malaria can be difficult to distinguish clinically, and rapid testing was not available in many Ebola Treatment Units (ETUs), guidelines recommended empirical malaria treatment. Little is known, however, about the prevalence and characteristics of patients entering an ETU who were infected with malaria parasites, either alone or concurrently with Ebola virus. Data for sociodemographics, disease characteristics, and mortality were analysed for patients with suspected EVD admitted to three ETUs in Sierra Leone using a retrospective cohort design. Testing for Ebola virus was done by real-time PCR and for malaria by a rapid diagnostic test. Characteristics of patients were compared and survival analyses were done to evaluate the effect of infection status on mortality. Between Dec 1, 2014, and Oct 15, 2015, 1524 cases were treated at the three ETUs for suspected EVD, of whom 1368 (90%) had diagnostic data for malaria and EVD. Median age of patients was 29 years (IQR 20-44) and 715 (52%) were men. 1114 patients were EVD negative, of whom 365 (33%) tested positive for malaria. Of 254 EVD positive patients, 53 (21%) also tested positive for malaria. Mortality risk was highest in patients diagnosed with both EVD and malaria (35 [66%] of 53 died) and patients diagnosed with EVD alone (105 [52%] of 201 died). Compared with patients presenting to ETUs without malaria or EVD, mortality was increased in the malaria positive and EVD positive group (adjusted hazard ratio 9·36, 95% CI 6·18-14·18, p<0·0001), and the malaria negative and EVD positive group (5·97, 4·44-8·02, p<0·0001), but reduced in the malaria positive and EVD negative group (0·37, 0·20-1·23, p=0·0010). Malaria parasite co-infection was common in patients presenting to ETUs and conferred an increased mortality risk in patients infected with Ebola virus, supporting empirical malaria treatment in ETUs. The high mortality among patients without EVD or malaria suggests expanded testing and treatment might improve care in future EVD epidemics. International Medical Corps. Copyright © 2017 Elsevier Ltd. All rights reserved.
Bhaskar, Rakesh; Mohanty, Banalata
2014-09-01
Pesticides acting as endocrine disrupting chemicals disrupt the homeostasis of body metabolism. The present study elucidated that the low dose coexposure of thyroid disrupting dithiocarbamate fungicide mancozeb (MCZ) and neonicotinoid insecticide imidacloprid (IMI) during lactation increased the risk of body weight gain in mice later in life. Body weight gain has been linked to pesticide-induced hypothyroidism and hyperprolactinemia and alteration of lipid profiles. In vivo results were substantiated with in silico molecular docking (MD) analysis that predicted the binding affinity of pesticides with thyroid hormone receptors (TRα and TRβ) and peroxisome proliferator activated receptor gamma (PPARγ), the major nuclear receptors of peripheral fat metabolism. Binding potency of MCZ and IMI was compared with that of T3, and its antagonist ethylene thiourea (ETU) as well as PPARγ agonist (rosiglitazone) and antagonist (HL005). MD simulation predicted that both MCZ and IMI may compete with T3 for binding with TRs. Imidazole group of IMI formed hydrogen bonds with TRs like that of ETU. MCZ may compete with rosiglitazone and HL005 for PPARγ, but IMI showed no affinity. Thus while both MCZ and IMI could disrupt the TRs functioning, MCZ alone may affect PPARγ. Coexposure of pesticides decreased the plasma thyroid hormones and increased the cholesterol and triglyceride. Individual pesticide exposure in low dose might not exert the threshold response to affect the receptors signaling further to cause hormonal/metabolic impairment. Thus, cumulative response of the mixture of thyroid disrupting pesticides can disrupt metabolic regulation through several pathways and contribute to gain in body weight. Copyright © 2014 Elsevier Inc. All rights reserved.
The Role of the People’s Republic of China in the East Bengal Crisis of 1971.
1973-01-01
propon-nt of close ties with the P]JC, and William J. 3arnds, in his book, India. Pakistan and The Great Powers, posits t1-0at ,::. Khan’s dismissal of...the Sino-Indian border was 1 2 William J. Barnds, "Moscow and South Asia," Prob- lems of Communism , May-June, 1972, p. 22. 1 31nterview with U.S...21 (924-27 A,’ 1971), 169. 44Michael, "Desiign f’or Aggre.:;ion," p. 01) 45AIlen S. Whitinir, " Chira ’.; New Iplom,!cy," r etu.: of Communism, November
NASA Technical Reports Server (NTRS)
Grubb, Matt
2016-01-01
The NASA Operational Simulator for Small Satellites (NOS3) is a suite of tools to aid in areas such as software development, integration test (IT), mission operations training, verification and validation (VV), and software systems check-out. NOS3 provides a software development environment, a multi-target build system, an operator interface-ground station, dynamics and environment simulations, and software-based hardware models. NOS3 enables the development of flight software (FSW) early in the project life cycle, when access to hardware is typically not available. For small satellites there are extensive lead times on many of the commercial-off-the-shelf (COTS) components as well as limited funding for engineering test units (ETU). Considering the difficulty of providing a hardware test-bed to each developer tester, hardware models are modeled based upon characteristic data or manufacturers data sheets for each individual component. The fidelity of each hardware models is such that FSW executes unaware that physical hardware is not present. This allows binaries to be compiled for both the simulation environment, and the flight computer, without changing the FSW source code. For hardware models that provide data dependent on the environment, such as a GPS receiver or magnetometer, an open-source tool from NASA GSFC (42 Spacecraft Simulation) is used to provide the necessary data. The underlying infrastructure used to transfer messages between FSW and the hardware models can also be used to monitor, intercept, and inject messages, which has proven to be beneficial for VV of larger missions such as James Webb Space Telescope (JWST). As hardware is procured, drivers can be added to the environment to enable hardware-in-the-loop (HWIL) testing. When strict time synchronization is not vital, any number of combinations of hardware components and software-based models can be tested. The open-source operator interface used in NOS3 is COSMOS from Ball Aerospace. For testing, plug-ins are implemented in COSMOS to control the NOS3 simulations, while the command and telemetry tools available in COSMOS are used to communicate with FSW. NOS3 is actively being used for FSW development and component testing of the Simulation-to-Flight 1 (STF-1) CubeSat. As NOS3 matures, hardware models have been added for common CubeSat components such as Novatel GPS receivers, ClydeSpace electrical power systems and batteries, ISISpace antenna systems, etc. In the future, NASA IVV plans to distribute NOS3 to other CubeSat developers and release the suite to the open-source community.
Aperture Valve for the Mars Organic Molecule Analyzer (MOMA)
NASA Technical Reports Server (NTRS)
Engler, Charles; Canham, John
2014-01-01
NASA's participation in the multi-nation ExoMars 2018 Rover mission includes a critical astrobiology Mass Spectrometer Instrument on the Rover called the Mars Organic Molecule Analyzer (MOMA). The Aperture Valve is a critical electromechanical valve used by the Mass Spectrometer to facilitate the transfer of ions from Martian soil to the Mass Spectrometer for analysis. The MOMA Aperture Valve development program will be discussed in terms of the initial valve design and subsequent improvements that resulted from prototype testing. The initial Aperture Valve concept seemed promising, based on calculations and perceived merits. However, performance results of this design were disappointing, due to delamination of TiN and DLC coatings applied to the titanium base metals, causing debris from the coatings to seize the valve. While peer reviews and design trade studies are important forums to vet a concept design, results from testing should not be underestimated. Despite the lack of development progress to meet requirements, valuable information from weakness discovered in the initial Valve design was used to develop a second, more robust Aperture Valve. Based on a check-ball design, the ETU / flight valve design resulted in significantly less surface area to create the seal. Moreover, PVD coatings were eliminated in favor of hardened, non-magnetic corrosion resistant alloys. Test results were impressive, with the valve achieving five orders of magnitude better sealing leak rate over end of life requirements. Cycle life was equally impressive, achieving 280,000 cycles without failure.
Aperture Valve for the Mars Organic Molecule Analyzer (MOMA)
NASA Technical Reports Server (NTRS)
Hakun, Claef F.; Engler, Charles D.; Barber, Willie E.; Canham, John S.
2014-01-01
NASA's participation in the multi-nation ExoMars 2018 Rover mission includes a critical astrobiology Mass Spectrometer Instrument on the Rover called the Mars Organic Molecule Analyzer (MOMA). The Aperture Valve is a critical electromechanical valve used by the Mass Spectrometer to facilitate the transfer of ions from Martian soil to the Mass Spectrometer for analysis. The MOMA Aperture Valve development program will be discussed in terms of the Initial valve design and subsequent improvements that resulted from prototype testing. The Initial Aperture Valve concept seemed promising, based on calculations and perceived merits. However, performance results of this design were disappointing, due to delamination of TiN and DLC coatings applied to the Titanium base metals, causing debris from the coatings to seize the valve. While peer reviews and design trade studies are important forums to vet a concept design, results from testing should not be underestimated.Despite the lack of development progress to meet requirements, valuable information from weakness discovered in the Initial Valve design was used to develop a second, more robust Aperture valve. Based on a check-ball design, the ETU flight valve design resulted in significantly less surface area to create the seal. Moreover, PVD coatings were eliminated in favor of hardened, nonmagnetic corrosion resistant alloys. Test results were impressive, with the valve achieving five orders of magnitude better sealing leak rate over end of life requirements. Cycle life was equally impressive, achieving 280,000 cycles without failure.
Aperture Valve for the Mars Organic Molecule Analyzer (MOMA)
NASA Technical Reports Server (NTRS)
Engler, Charles D.; Canham, John S.
2014-01-01
NASA's participation in the multi-nation ExoMars 2018 Rover mission includes a critical astrobiology Mass Spectrometer Instrument on the Rover called the Mars Organic Molecule Analyzer (MOMA). The Aperture Valve is a critical electromechanical valve used by the Mass Spectrometer to facilitate the transfer of ions from Martian soil to the Mass Spectrometer for analysis. The MOMA Aperture Valve development program will be discussed in terms of the Initial valve design and subsequent improvements that resulted from prototype testing. The Initial Aperture Valve concept seemed promising, based on calculations and perceived merits. However, performance results of this design were disappointing, due to delamination of TiN and DLC coatings applied to the Titanium base metals, causing debris from the coatings to seize the valve. While peer reviews and design trade studies are important forums to vet a concept design, results from testing should not be underestimated. Despite the lack of development progress to meet requirements, valuable information from weakness discovered in the Initial Valve design was used to develop a second, more robust Aperture valve. Based on a check-ball design, the ETU /flight valve design resulted in significantly less surface area to create the seal. Moreover, PVD coatings were eliminated in favor of hardened, nonmagnetic corrosion resistant alloys. Test results were impressive, with the valve achieving five orders of magnitude better sealing leak rate over end of life requirements. Cycle life was equally impressive, achieving 280,000 cycles without failure.
Performance of the future MOMA GC-ITMS instrument
NASA Astrophysics Data System (ADS)
Grand, Noel; Buch, Arnaud; Veronica, Pinnick; Szopa, Cyril; Danell, Ryan; Van Amerom, Friso H. W.; Glavin, Daniel P.; Freissinet, Caroline; Arevalo, Ricardo; Stalport, Fabien; Getty, Stephanie; Coll, Patrice; Steinninger, Harald; Brinckerhoff, William; Mahaffy, Paul; Goesmann, Fred; Raulin, F.; Goetz, Walter; MOMA Team
2016-10-01
The Mars Organic Molecule Analyzer (MOMA) experiment aboard the future ExoMars mission will be the continuation of the SAM expirement aboard the Curiosity rover, with the search for the organic composition of the Mars surface. With ExoMars the sample will be extracted as deep as 2 meters below the martian surface to minimize effects of radiation and oxidation on organic materials. To analyze the wide range of organic composition (volatile and non-volatiles compounds) of the Martian soil MOMA is composed with an UV laser desorption / ionization (LDI) and a pyrolysis gas chromatography ion trap mass spectrometry (pyr-GC-ITMS). In order to analyze refractory organic compounds and chirality samples which undergo GC-ITMS analysis may be submitted to a derivatization process, consisting of the reaction of the sample components with specific reactants (MTBSTFA [1], DMF-DMA [2] or TMAH [3]).To optimize and test the performance of the GC-ITMS instrument we have performed several coupling tests campaigns between the GC, providing by the French team (LISA, LATMOS, CentraleSupelec), and the MS, providing by the US team (NASA, GSFC). Last campaign has been done with the ETU models which is similar to the flight model and which include the oven and the taping station providing by the German team (MPS).The results obtained demonstrate the current status of the end-to-end performance of the gas chromatography-mass spectrometry mode of operation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marra, J.; Fox, K.; Farfan, E.
2009-12-08
The DOE Office of Environmental Management (DOE-EM) Office of Engineering and Technology is responsible for implementing EM's International Cooperative Program. Over the past 15 years, collaborative work has been conducted through this program with researchers in Russia, Ukraine, France, United Kingdom and Republic of Korea. Currently, work is being conducted with researchers in Russia and Ukraine. Efforts aimed at evaluating and advancing technologies to support U.S. high-level waste (HLW) vitrification initiatives are being conducted in collaboration with Russian researchers. Work at Khlopin Radium Institute (KRI) is targeted at improving the throughput of current vitrification processes by increasing melting rate. Thesemore » efforts are specifically targeted at challenging waste types identified at the Savannah River Site (SRS) and Hanford Site. The objectives of current efforts at SIA Radon are to gain insight into vitrification process limits for the cold crucible induction melter (CCIM) technology. Previous demonstration testing has shown that the CCIM offers the potential for dramatic increases in waste loading and waste throughput. However, little information is known regarding operational limits that could affect long-term, efficient CCIM operations. Collaborative work with the Russian Electrotechnical University (ETU) 'LETI' is aimed at advancing CCIM process monitoring, process control and design. The goal is to further mature the CCIM technology and to establish it as a viable HLW vitrification technology. The greater than two year effort conducted with the International Radioecology Laboratory in the Ukraine recently completed. The objectives of this study were: to assess the long-term impacts to the environment from radiation exposure in the Chernobyl Exclusion Zone (ChEZ); and to provide information on remediation guidelines and ecological risk assessment within radioactively contaminated territories around the Chernobyl Nuclear Power Plant (ChNPP) based on the results of long-term field monitoring, analytical measurements, and numerical modeling of soils and groundwater radioactive contamination.« less
1993-03-01
cervV epa Addm Ing. J.A. van (3ooI - 12-02-1993 It7T- PAPOTNCNTAE g,: Accesion For Frederikkaze~rne, gebouw 140 OGRBIER TS CAI T v/ d Burchlaafl 31 HPC...16A r~l D TIC -;S TEL. 070-3166394/6395 ONGERUBRICEERD) !’ ,ro’ ;Cc FAX. (31) 070-.3166202 Srevtil:JSl--to ElostbUs 90701 Saiqwag ......zto I...Tabel I geeft d onderdelen van de TNO~~~~-SC e e fiknemattnozc a ei etU rnebe[I] becrvnSB Tae I ljtvnodreediqu atvscinvnd I-C TaeD ef e onder d n o
Roshania, Reshma; Mallow, Michaela; Dunbar, Nelson; Mansary, David; Shetty, Pranav; Lyon, Taralyn; Pham, Kacey; Abad, Matthew; Shedd, Erin; Tran, Anh-Minh A; Cundy, Sarah; Levine, Adam C
2016-09-28
The 2014 outbreak of Ebola virus disease (EVD) in West Africa was the largest ever recorded. Starting in September 2014, International Medical Corps (IMC) managed 5 Ebola treatment units (ETUs) in Liberia and Sierra Leone, which cumulatively cared for about 2,500 patients. We conducted a retrospective cohort study of patient data collected at the 5 ETUs over 1 year of operations. To collect clinical and epidemiological data from the patient care areas, each chart was either manually copied across the fence between the high-risk zone and low-risk zone, imaged across the fence, or imaged in the high-risk zone. Each ETU's data were entered into a separate electronic database, and these were later combined into a single relational database. Lot quality assurance sampling was used to ensure data quality, with reentry of data with high error rates from imaged records. The IMC database contains records on 2,768 patient presentations, including 2,351 patient admissions with full follow-up data. Of the patients admitted, 470 (20.0%) tested positive for EVD, with an overall case fatality ratio (CFR) of 57.0% for EVD-positive patients and 8.1% for EVD-negative patients. Although more men were admitted than women (53.4% vs. 46.6%), a larger proportion of women were diagnosed EVD positive (25.6% vs. 15.2%). Diarrhea, red eyes, contact with an ill person, and funeral attendance were significantly more common in patients with EVD than in those with other diagnoses. Among EVD-positive patients, age was a significant predictor of mortality: the highest CFRs were among children under 5 (89.1%) and adults over 55 (71.4%). While several prior reports have documented the experiences of individual ETUs, this study is the first to present data from multiple ETUs across 2 countries run by the same organization with similar clinical protocols. Our experience demonstrates that even in austere settings under difficult conditions, it is possible for humanitarian organizations to collect high-quality clinical and epidemiologic data during a major infectious disease outbreak. © Roshania et al.
Linear Ion Traps in Space: The Mars Organic Molecule Analyzer (MOMA) Instrument and Beyond
NASA Astrophysics Data System (ADS)
Arevalo, Ricardo; Brinckerhoff, William; Mahaffy, Paul; van Amerom, Friso; Danell, Ryan; Pinnick, Veronica; Li, Xiang; Hovmand, Lars; Getty, Stephanie; Grubisic, Andrej; Goesmann, Fred; Cottin, Hervé
2015-11-01
Historically, quadrupole mass spectrometer (QMS) instruments have been used to explore a wide survey of planetary targets in our solar system, from Venus (Pioneer Venus) to Saturn (Cassini-Huygens). However, linear ion trap (LIT) mass spectrometers have found a niche as smaller, versatile alternatives to traditional quadrupole analyzers.The core astrobiological experiment of ESA’s ExoMars Program is the Mars Organic Molecule Analyzer (MOMA) onboard the ExoMars 2018 rover. The MOMA instrument is centered on a linear (or 2-D) ion trap mass spectrometer. As opposed to 3-D traps, LIT-based instruments accommodate two symmetrical ion injection pathways, enabling two complementary ion sources to be used. In the case of MOMA, these two analytical approaches are laser desorption mass spectrometry (LDMS) at Mars ambient pressures, and traditional gas chromatography mass spectrometry (GCMS). The LIT analyzer employed by MOMA also offers: higher ion capacity compared to a 3-D trap of the same volume; redundant detection subassemblies for extended lifetime; and, a link to heritage QMS designs and assembly logistics. The MOMA engineering test unit (ETU) has demonstrated the detection of organics in the presence of wt.%-levels of perchlorate, effective ion enhancement via stored waveform inverse Fourier transform (SWIFT), and derivation of structural information through tandem mass spectrometry (MS/MS).A more progressive linear ion trap mass spectrometer (LITMS), funded by the NASA ROSES MatISSE Program, is being developed at NASA GSFC and promises to augment the capabilities of the MOMA instrument by way of: an expanded mass range (i.e., 20 - 2000 Da); detection of both positive and negative ions; spatially resolved (<1 mm) characterization of individual rock core layers; and, evolved gas analysis and GCMS with pyrolysis up to 1300° C (enabling breakdown of refractory phases). The Advanced Resolution Organic Molecule Analyzer (AROMA) instrument, being developed through NASA PICASSO and ESA Research and Development Programs, combines a highly capable LIT front end (a la LITMS) with a high-resolution OrbitrapTM (a la CosmOrbitrap) mass analyzer to enable disambiguation of complex molecular signals in organic-rich targets.
Independent Orbiter Assessment (IOA): Analysis of the mechanical actuation subsystem
NASA Technical Reports Server (NTRS)
Bacher, J. L.; Montgomery, A. D.; Bradway, M. W.; Slaughter, W. T.
1987-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Mechanical Actuation System (MAS) hardware. Specifically, the MAS hardware consists of the following components: Air Data Probe (ADP); Elevon Seal Panel (ESP); External Tank Umbilical (ETU); Ku-Band Deploy (KBD); Payload Bay Doors (PBD); Payload Bay Radiators (PBR); Personnel Hatches (PH); Vent Door Mechanism (VDM); and Startracker Door Mechanism (SDM). The IOA analysis process utilized available MAS hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.
Plouff, Donald
2000-01-01
Gravity observations are directly made or are obtained from other sources by the U.S. Geological Survey in order to prepare maps of the anomalous gravity field and consequently to interpret the subsurface distribution of rock densities and associated lithologic or geologic units. Observations are made in the field with gravity meters at new locations and at reoccupations of previously established gravity "stations." This report illustrates an interactively-prompted series of steps needed to convert gravity "readings" to values that are tied to established gravity datums and includes computer programs to implement those steps. Inasmuch as individual gravity readings have small variations, gravity-meter (instrument) drift may not be smoothly variable, and acommodations may be needed for ties to previously established stations, the reduction process is iterative. Decision-making by the program user is prompted by lists of best values and graphical displays. Notes about irregularities of topography, which affect the value of observed gravity but are not shown in sufficient detail on topographic maps, must be recorded in the field. This report illustrates ways to record field notes (distances, heights, and slope angles) and includes computer programs to convert field notes to gravity terrain corrections. This report includes approaches that may serve as models for other applications, for example: portrayal of system flow; style of quality control to document and validate computer applications; lack of dependence on proprietary software except source code compilation; method of file-searching with a dwindling list; interactive prompting; computer code to write directly in the PostScript (Adobe Systems Incorporated) printer language; and high-lighting the four-digit year on the first line of time-dependent data sets for assured Y2K compatibility. Computer source codes provided are written in the Fortran scientific language. In order for the programs to operate, they first must be converted (compiled) into an executable form on the user's computer. Although program testing was done in a UNIX (tradename of American Telephone and Telegraph Company) computer environment, it is anticipated that only a system-dependent date-and-time function may need to be changed for adaptation to other computer platforms that accept standard Fortran code.d del iliscipit volorer sequi ting etue feum zzriliquatum zzriustrud esenibh ex esto esequat.
Link performance model for filter bank based multicarrier systems
NASA Astrophysics Data System (ADS)
Petrov, Dmitry; Oborina, Alexandra; Giupponi, Lorenza; Stitz, Tobias Hidalgo
2014-12-01
This paper presents a complete link level abstraction model for link quality estimation on the system level of filter bank multicarrier (FBMC)-based networks. The application of mean mutual information per coded bit (MMIB) approach is validated for the FBMC systems. The considered quality measure of the resource element for the FBMC transmission is the received signal-to-noise-plus-distortion ratio (SNDR). Simulation results of the proposed link abstraction model show that the proposed approach is capable of estimating the block error rate (BLER) accurately, even when the signal is propagated through the channels with deep and frequent fades, as it is the case for the 3GPP Hilly Terrain (3GPP-HT) and Enhanced Typical Urban (ETU) models. The FBMC-related results of link level simulations are compared with cyclic prefix orthogonal frequency division multiplexing (CP-OFDM) analogs. Simulation results are also validated through the comparison to reference publicly available results. Finally, the steps of link level abstraction algorithm for FBMC are formulated and its application for system level simulation of a professional mobile radio (PMR) network is discussed.
Prediction of anti-cancer drug response by kernelized multi-task learning.
Tan, Mehmet
2016-10-01
Chemotherapy or targeted therapy are two of the main treatment options for many types of cancer. Due to the heterogeneous nature of cancer, the success of the therapeutic agents differs among patients. In this sense, determination of chemotherapeutic response of the malign cells is essential for establishing a personalized treatment protocol and designing new drugs. With the recent technological advances in producing large amounts of pharmacogenomic data, in silico methods have become important tools to achieve this aim. Data produced by using cancer cell lines provide a test bed for machine learning algorithms that try to predict the response of cancer cells to different agents. The potential use of these algorithms in drug discovery/repositioning and personalized treatments motivated us in this study to work on predicting drug response by exploiting the recent pharmacogenomic databases. We aim to improve the prediction of drug response of cancer cell lines. We propose to use a method that employs multi-task learning to improve learning by transfer, and kernels to extract non-linear relationships to predict drug response. The method outperforms three state-of-the-art algorithms on three anti-cancer drug screen datasets. We achieved a mean squared error of 3.305 and 0.501 on two different large scale screen data sets. On a recent challenge dataset, we obtained an error of 0.556. We report the methodological comparison results as well as the performance of the proposed algorithm on each single drug. The results show that the proposed method is a strong candidate to predict drug response of cancer cell lines in silico for pre-clinical studies. The source code of the algorithm and data used can be obtained from http://mtan.etu.edu.tr/Supplementary/kMTrace/. Copyright © 2016 Elsevier B.V. All rights reserved.
Independent Orbiter Assessment (IOA): Assessment of the mechanical actuation subsystem, volume 1
NASA Technical Reports Server (NTRS)
Bradway, M. W.; Slaughter, W. T.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine draft failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline that was available. A resolution of each discrepancy from the comparison was provided through additional analysis as required. These discrepancies were flagged as issues, and recommendations were made based on the FMEA data available at the time. This report documents the results of that comparison for the Orbiter Mechanical Actuation System (MAS) hardware. Specifically, the MAS hardware consists of the following components: Air Data Probe (ADP); Elevon Seal Panel (ESP); External Tank Umbilical (ETU); Ku-Band Deploy (KBD); Payload Bay Doors (PBD); Payload Bay Radiators (PBR); Personnel Hatches (PH); Vent Door Mechanism (VDM); and Startracker Door Mechanism (SDM). Criticality was assigned based upon the severity of the effect for each failure mode.
Performances of the Mars Organic Molecule Analyzer (MOMA) GC-MS suite aboard ExoMars Mission
NASA Astrophysics Data System (ADS)
Buch, A.; Grand, N.; Pinnick, V. T.; Szopa, C.; Humeau, O.; Danell, R.; van Amerom, F. H. W.; Freissinet, C.; Glavin, D. P.; Belmahdi, I.; Coll, P. J.; Lustrement, B.; Brinckerhoff, W. B.; Arevalo, R. D., Jr.; Stalport, F.; Steininger, H.; Goesmann, F.; Raulin, F.; Mahaffy, P. R.
2014-12-01
The Mars Organic Molecule Analyzer (MOMA) aboard the ExoMars rover (Pasteur) will be a key analytical tool in providing chemical (molecular) information from the solid samples collected by the rover, with a particular focus on the characterization of the organic content. Samples will be extracted as deep as 2 meters below the martian surface to minimize effects of radiation and oxidation on organic materials. The core of the MOMA instrument is a dual source UV laser desorption / ionization (LDI) and pyrolysis gas chromatography (pyr-GC) ion trap mass spectrometer (ITMS) which provides the unique capability to characterize a broad range of compounds, including both of volatile and non-volatile species. Samples which undergo GC-ITMS analysis may be submitted to a derivatization process, consisting of the reaction of the sample components with specific reactants (MTBSTFA [1], DMF-DMA [2] or TMAH [3]) which increase the volatility of complex organic species. With the goal to optimize this instrumentation, and especially the GC-ITMS coupling, a series of tests is currently being carried out with prototypes of MOMA instrumentation and with the ETU models wich is similar to the flight model. The MOMA oven and tapping station are also part of these end-to-end experiments. Qualitative and quantitative tests has been done on gas, liquid and solid samples. The results obtained demonstrate the current status of the end-to-end performance of the gas chromatography-mass spectrometry mode of operation. Both prototypes individually meet the performance requirements, but this work particularly demonstrates the capabilities of the critical GC-MS interface. References: [1] Buch, A. et al. (2009) J chrom. A, 43, 143-151. [2] Freissinet et al. (2011) J Chrom A, 1306, 59-71. [3] Geffroy-Rodier, C. et al. (2009) JAAP, 85, 454-459. Acknowledgements: Funding provided by the Mars Exploration Program (point of contact, George Tahu, NASA/HQ). MOMA is a collaboration between NASA and ESA (PI Goesmann, MPS). MOMA-GC team acknowledges support from the French Space Agency (CNES), French National Programme of Planetology (PNP), National French Council (CNRS), Pierre Simon Laplace Institute.
Wilken, Jason A; Pordell, Paran; Goode, Brant; Jarteh, Rachel; Miller, Zayzay; Saygar, Benjamin G; Maximore, Leroy; Borbor, Watta M; Carmue, Moses; Walker, Gregory W; Yeiah, Adolphus
2017-12-01
In early 2015, a patient from a cluster of cases of Ebola Virus Disease (EVD) in Monrovia, Liberia traveled to a rural village in Margibi County, potentially exposing numerous persons. The patient died in the village and post-mortem testing confirmed Ebola Virus infection. Problem The Margibi County Health Team (CHT; Kakata, Margibi, Liberia) needed to prevent further transmission of EVD within and outside of the affected villages, and they needed to better understand the factors that support or impede compliance with measures to stop the spread of EVD. In February-March 2015, the Margibi CHT instituted a 21-day quarantine and active monitoring for two villages where the patient had contact with numerous residents, and a 21-day active monitoring for five other villages where the patient had possible contact with an unknown number of persons. One contact developed EVD and quarantine was extended an additional 12 days in one village. In April 2015, the Margibi CHT conducted a household-based EVD knowledge, attitudes, and practices (KAP) survey of the seven villages. From April 24-29, 2015, interview teams approached every household in the seven villages and collected information on demographics, knowledge of EVD, attitudes about quarantine to prevent the spread of EVD, and their quarantine experiences and practices. Descriptive statistics were calculated. One hundred fifteen interviews were conducted, representing the majority of the households in the seven villages. Most (99%) correctly identified touching an infected person's body fluids and contact with the body of someone who has died from EVD as transmission routes. However, interviewees sometimes incorrectly identified mosquito bites (58%) and airborne spread (32%) as routes of EVD transmission, and 72% incorrectly identified the longest EVD incubation period as ≤seven days. Eight of 16 households in the two quarantined villages (50%) reported times when there was not enough water or food during quarantine. Nine of 16 (56%) reported that a household member had illnesses or injuries during quarantine; of these, all (100%) obtained care from a clinic, hospital, or Ebola treatment unit (ETU). Residents' knowledge of EVD transmission routes and incubation period were suboptimal. Public health authorities should consider assessing residents' understanding of Ebola transmission routes and effectively educate them to ensure correct understanding. Quarantined residents should be provided with sufficient food, water, and access to medical care. Wilken JA , Pordell P , Goode B , Jarteh R , Miller Z , Saygar BG Sr. , Maximore L , Borbor WM , Carmue M , Walker GW , Yeiah A . Knowledge, attitudes, and practices among members of households actively monitored or quarantined to prevent transmission of Ebola Virus Disease - Margibi County, Liberia: February-March 2015. Prehosp Disaster Med. 2017;32(6):673-678.
Chu, Yushi; Ren, Jing; Zhang, Jianzhong; Peng, Gangding; Yang, Jun; Wang, Pengfei; Yuan, Libo
2016-01-01
Erbium doped bismuth borosilicate (BBS) glasses, possessing the broadest 1.55 μm near infrared (NIR) emission band among oxide glasses, stand out as excellent fiber material for optical fiber amplifiers. In this work, we demonstrate that both broadened and enhanced NIR emission of Er3+ can be obtained by sensibly combining the effects such as mixed glass former effect, phonon-assisted energy transfer (PAET) and de-excitation effect induced by codopant. Specially, by codoping CeO2 in a controlled manner, it leads to not only much improved optical quality of the glasses, enhanced NIR emission, but also significantly suppressed energy transfer up-conversion (ETU) luminescence which is detrimental to the NIR emission. Cerium incorporated in the glasses exists overwhelmingly as the trivalent oxidation state Ce3+ and its effects on the luminescence properties of Er3+ are discussed. Judd-Ofelt analysis is used to evaluate gain amplification of the glasses. The result indicates that Ce3+/Yb3+/Er3+ triply doped BBS glasses are promising candidate for erbium doped fiber amplifiers. The strategy described here can be readily extended to other rare-earth ions (REs) to improve the performance of REs doped fiber lasers and amplifiers. PMID:27646191
Nabitz, Udo; Smit, Filip; Koeter, Maarten WJ; Schippers, Gerard M
2012-01-01
Background Internet interventions with and without therapist support have been found to be effective treatment options for harmful alcohol users. Internet-based therapy (IT) leads to larger and longer-lasting positive effects than Internet-based self-help (IS), but it is also more costly to provide. Objective To evaluate the cost effectiveness and cost utility of Internet-based interventions for harmful use of alcohol through the assessment of the incremental cost effectiveness of IT compared with IS. Methods This study was performed in a substance abuse treatment center in Amsterdam, the Netherlands. We collected data over the years 2008–2009. A total of 136 participants were included, 70 (51%) were female, and mean age was 41.5 (SD 9.83) years. Reported alcohol consumption and Alcohol Use Disorders Identification Test (AUDIT) scores indicated harmful drinking behavior at baseline. We collected self-reported outcome data prospectively at baseline and 6 months after randomization. Cost data were extracted from the treatment center’s cost records, and sex- and age-specific mean productivity cost data for the Netherlands. Results The median incremental cost-effectiveness ratio was estimated at €3683 per additional treatment responder and €14,710 per quality-adjusted life-year (QALY) gained. At a willingness to pay €20,000 for 1 additional QALY, IT had a 60% likelihood of being more cost effective than IS. Sensitivity analyses attested to the robustness of the findings. Conclusions IT offers better value for money than IS and might therefore be considered as a treatment option, either as first-line treatment in a matched-care approach or as a second-line treatment in the context of a stepped-care approach. Trial Registration Netherlands Trial Register NTR-TC1155; http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=1155 (Archived by WebCite at http://www.webcitation.org/6AqnV4eTU) PMID:23103771
Independent Orbiter Assessment (IOA): Assessment of the mechanical actuation subsystem, volume 2
NASA Technical Reports Server (NTRS)
Bradway, M. W.; Slaughter, W. T.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine draft failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline that was available. A resolution of each discrepancy from the comparison was provided through additional analysis as required. These discrepancies were flagged as issues, and recommendations were made based on the FMEA data available at the time. This report documents the results of that comparison for the Orbiter Mechanical Actuation System (MAS) hardware. Specifically, the MAS hardware consists of the following components: Air Data Probe (ADP); Elevon Seal Panel (ESP); External Tank Umbilical (ETU); Ku-Band Deploy (KBD); Payload Bay Doors (PBD); Payload Bay Radiators (PBR); Personnel Hatches (PH); Vent Door Mechanism (VDM); and Startracker Door Mechanism (SDM). Criticality was assigned based upon the severity of the effect for each failure mode. Volume 2 continues the presentation of IOA analysis worksheets and contains the potential critical items list, detailed analysis, and NASA FMEA/CIL to IOA worksheet cross reference and recommendations.
System Testing of Ground Cooling System Components
NASA Technical Reports Server (NTRS)
Ensey, Tyler Steven
2014-01-01
This internship focused primarily upon software unit testing of Ground Cooling System (GCS) components, one of the three types of tests (unit, integrated, and COTS/regression) utilized in software verification. Unit tests are used to test the software of necessary components before it is implemented into the hardware. A unit test determines that the control data, usage procedures, and operating procedures of a particular component are tested to determine if the program is fit for use. Three different files are used to make and complete an efficient unit test. These files include the following: Model Test file (.mdl), Simulink SystemTest (.test), and autotest (.m). The Model Test file includes the component that is being tested with the appropriate Discrete Physical Interface (DPI) for testing. The Simulink SystemTest is a program used to test all of the requirements of the component. The autotest tests that the component passes Model Advisor and System Testing, and puts the results into proper files. Once unit testing is completed on the GCS components they can then be implemented into the GCS Schematic and the software of the GCS model as a whole can be tested using integrated testing. Unit testing is a critical part of software verification; it allows for the testing of more basic components before a model of higher fidelity is tested, making the process of testing flow in an orderly manner.
Architecture-Based Unit Testing of the Flight Software Product Line
NASA Technical Reports Server (NTRS)
Ganesan, Dharmalingam; Lindvall, Mikael; McComas, David; Bartholomew, Maureen; Slegel, Steve; Medina, Barbara
2010-01-01
This paper presents an analysis of the unit testing approach developed and used by the Core Flight Software (CFS) product line team at the NASA GSFC. The goal of the analysis is to understand, review, and reconunend strategies for improving the existing unit testing infrastructure as well as to capture lessons learned and best practices that can be used by other product line teams for their unit testing. The CFS unit testing framework is designed and implemented as a set of variation points, and thus testing support is built into the product line architecture. The analysis found that the CFS unit testing approach has many practical and good solutions that are worth considering when deciding how to design the testing architecture for a product line, which are documented in this paper along with some suggested innprovennents.
29 CFR 1919.71 - Unit proof test and examination of cranes.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 7 2011-07-01 2011-07-01 false Unit proof test and examination of cranes. 1919.71 Section... § 1919.71 Unit proof test and examination of cranes. (a) Unit proof tests of cranes shall be carried out at the following times: (1) In the cases of new cranes, before initial use and every 4 years...
29 CFR 1919.71 - Unit proof test and examination of cranes.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 7 2010-07-01 2010-07-01 false Unit proof test and examination of cranes. 1919.71 Section... § 1919.71 Unit proof test and examination of cranes. (a) Unit proof tests of cranes shall be carried out at the following times: (1) In the cases of new cranes, before initial use and every 4 years...
Unit Testing for Command and Control Systems
NASA Technical Reports Server (NTRS)
Alexander, Joshua
2018-01-01
Unit tests were created to evaluate the functionality of a Data Generation and Publication tool for a command and control system. These unit tests are developed to constantly evaluate the tool and ensure it functions properly as the command and control system grows in size and scope. Unit tests are a crucial part of testing any software project and are especially instrumental in the development of a command and control system. They save resources, time and costs associated with testing, and catch issues before they become increasingly difficult and costly. The unit tests produced for the Data Generation and Publication tool to be used in a command and control system assure the users and stakeholders of its functionality and offer assurances which are vital in the launching of spacecraft safely.
ACER Physics Unit Tests: Unit Tests, Diagnostic Aids, [and] Teachers Handbook.
ERIC Educational Resources Information Center
Australian Council for Educational Research, Hawthorn.
The Physics Unit Tests are designed to assist in the diagnostic evaluation of students' progress in the study of physics during the last two years of secondary schooling. They consist of a collection of 21 separate tests, each related to a different topic, and 21 diagnostic aids corresponding to the tests. The topics covered are: physical…
42 CFR 84.310 - Post-approval testing.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Respirators § 84.310 Post-approval testing. (a) NIOSH will periodically test the capacity and performance of units of approved CCERs. (b) NIOSH may test units that are new and/or units that have been deployed in... 42 Public Health 1 2014-10-01 2014-10-01 false Post-approval testing. 84.310 Section 84.310 Public...
42 CFR 84.310 - Post-approval testing.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Respirators § 84.310 Post-approval testing. (a) NIOSH will periodically test the capacity and performance of units of approved CCERs. (b) NIOSH may test units that are new and/or units that have been deployed in... 42 Public Health 1 2013-10-01 2013-10-01 false Post-approval testing. 84.310 Section 84.310 Public...
42 CFR 84.310 - Post-approval testing.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Respirators § 84.310 Post-approval testing. (a) NIOSH will periodically test the capacity and performance of units of approved CCERs. (b) NIOSH may test units that are new and/or units that have been deployed in... 42 Public Health 1 2012-10-01 2012-10-01 false Post-approval testing. 84.310 Section 84.310 Public...
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
The most common method of measuring air leakage is to perform single (or solo) blower door pressurization and/or depressurization test. In detached housing, the single blower door test measures leakage to the outside. In attached housing, however, this "solo" test method measures both air leakage to the outside and air leakage between adjacent units through common surfaces. Although minimizing leakage to neighboring units is highly recommended to avoid indoor air quality issues between units, reduce pressure differentials between units, and control stack effect, the energy benefits of air sealing can be significantly overpredicted if the solo air leakage number ismore » used in the energy analysis. Guarded blower door testing is more appropriate for isolating and measuring leakage to the outside in attached housing. This method uses multiple blower doors to depressurize adjacent spaces to the same level as the unit being tested. Maintaining a neutral pressure across common walls, ceilings, and floors acts as a "guard" against air leakage between units. The resulting measured air leakage in the test unit is only air leakage to the outside. Although preferred for assessing energy impacts, the challenges of performing guarded testing can be daunting.« less
NASA Technical Reports Server (NTRS)
Platt, R.
1999-01-01
This is the Performance Verification Report, Initial Comprehensive Performance Test Report, P/N 1331200-2-IT, S/N 105/A2, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). The specification establishes the requirements for the Comprehensive Performance Test (CPT) and Limited Performance Test (LPT) of the Advanced Microwave Sounding, Unit-A2 (AMSU-A2), referred to herein as the unit. The unit is defined on Drawing 1331200. 1.2 Test procedure sequence. The sequence in which the several phases of this test procedure shall take place is shown in Figure 1, but the sequence can be in any order.
ARI Environmental, Inc. (ARI) was retained by Houston Refining LP (HRO) to conduct an emission test program at their refinery located in Houston, Texas. The testing was conducted on on the 736 Delayed Coking Unit (DCU) in response to EPA's ICR.
Test Report of Special Form Qualification Testing for the ORNL U ZipCan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinez, Oscar A.
This test report describes the special form testing activities performed on the two ZiPCans. One prototype test unit was subjected to the tests stipulated by 10 CFR 71.75 (d)(1)(i), ISO 2919:1999(E) Class 4 impact test, along with the leak rate test specified in 49 CFR 173.469(a)(4)(i). The other test unit was subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469 (b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests, as specified in ANSImore » N14.5-2014.The measured leak rates were converted to standard condition leak rates as specified in ASTM E 493. The determined standardized leak rates from the test and calculation for both test units met the requirements for special form certification.« less
NASA Technical Reports Server (NTRS)
Zachary, A. T.; Csomor, A.; Tignac, L. L.
1973-01-01
Small, high-performance LO2 and LH2 turbopump assembly configurations were selected, detail designs were prepared and two of each unit were fabricated with each unit consisting of pump, turbine gas generator, and appropriate controls. Following fabrication, development testing was conducted on each type to demonstrate performance, durability, transient characteristics, and heat transfer under simulated altitude conditions. Following successful completion of development effort, the two LO2 turbopump units and one LH2 turbopump unit were acceptance tested as specified. Inspection of the units following development testing revealed no deleterious effects of testing. The test results of LO2 turbopump assembly testing correlated well with predicted performance while the LH2 turbopump test results, though generally consistent with predicted values, did show lower than anticipated developed head at the design point and in the high flow range of operation.
What nanomedicine in the clinic right now really forms nanoparticles?
Svenson, Sonke
2014-01-01
Some researchers believe nanomedicine will revolutionize healthcare and medicine through transformative new therapeutic tools. Nanocarriers, utilized to transport actives to the target site, are constructed from a wide range of materials. Nanocarriers can be grouped into self-assembling (liposomes, micelles), processed (nanoparticles, emulsions), and chemically bound (dendrimers, silica-based carriers, carbon nanotubes) structures. A review of nanomedicines on the market and in clinical translation reveals that the vast majority is based on liposomes, polymeric micelles, and nanoparticles. The increasing presence of these novel nanomedicines raises the question what nanomedicines in the clinic right now really form nanoparticles, i.e., are improvements we see from nanomedicines structure-related or do they result from improved formulations? Do we even have sufficient data to address this question? The formation of nanocarriers is usually confirmed in vitro but little if any in vivo (let alone clinical) information is available. Given the large number of nanomedicines on the market and under clinical evaluation one clearly cannot expect to find a 'one size fits all' answer. Therefore, two case studies are discussed: the paclitaxel formulation Taxol® and its nanomedicine companions LEP-ETU (liposome), Genexol®-PM and NK105 (micelles), and Abraxane® (nanoparticle). Published pharmacokinetic data is utilized to find differences indicating nanocarrier delivery. The second case study involves structurally related camptothecin-polymer conjugates CRLX101 (nanoparticles) and XMT-1001 (prodrug). Structural differences are evaluated to discuss the different aggregation behavior. This opinion can only serve as first attempt to find a more general answer; clearly more data is needed from future studies. © 2014 Wiley Periodicals, Inc.
Cost implications of implementation of pathogen-inactivated platelets
McCullough, Jeffrey; Goldfinger, Dennis; Gorlin, Jed; Riley, William J; Sandhu, Harpreet; Stowell, Christopher; Ward, Dawn; Clay, Mary; Pulkrabek, Shelley; Chrebtow, Vera; Stassinopoulos, Adonis
2015-01-01
BACKGROUND Pathogen inactivation (PI) is a new approach to blood safety that may introduce additional costs. This study identifies costs that could be eliminated, thereby mitigating the financial impact. STUDY DESIGN AND METHODS Cost information was obtained from five institutions on tests and procedures (e.g., irradiation) currently performed, that could be eliminated. The impact of increased platelet (PLT) availability due to fewer testing losses, earlier entry into inventory, and fewer outdates with a 7-day shelf life were also estimated. Additional estimates include costs associated with managing 1) special requests and 2) test results, 3) quality control and proficiency testing, 4) equipment acquisition and maintenance, 5) replacement of units lost to positive tests, 6) seasonal or geographic testing, and 7) health department interactions. RESULTS All costs are mean values per apheresis PLT unit in USD ($/unit). The estimated test costs that could be eliminated are $71.76/unit and a decrease in transfusion reactions corresponds to $2.70/unit. Avoiding new tests (e.g., Babesia and dengue) amounts to $41.80/unit. Elimination of irradiation saves $8.50/unit, while decreased outdating with 7-day storage can be amortized to $16.89/unit. Total potential costs saved with PI is $141.65/unit. Costs are influenced by a variety of factors specific to institutions such as testing practices and the location in which such costs are incurred and careful analysis should be performed. Additional benefits, not quantified, include retention of some currently deferred donors and scheduling flexibility due to 7-day storage. CONCLUSIONS While PI implementation will result in additional costs, there are also potential offsetting cost reductions, especially after 7-day storage licensing. PMID:25989465
Cost implications of implementation of pathogen-inactivated platelets.
McCullough, Jeffrey; Goldfinger, Dennis; Gorlin, Jed; Riley, William J; Sandhu, Harpreet; Stowell, Christopher; Ward, Dawn; Clay, Mary; Pulkrabek, Shelley; Chrebtow, Vera; Stassinopoulos, Adonis
2015-10-01
Pathogen inactivation (PI) is a new approach to blood safety that may introduce additional costs. This study identifies costs that could be eliminated, thereby mitigating the financial impact. Cost information was obtained from five institutions on tests and procedures (e.g., irradiation) currently performed, that could be eliminated. The impact of increased platelet (PLT) availability due to fewer testing losses, earlier entry into inventory, and fewer outdates with a 7-day shelf life were also estimated. Additional estimates include costs associated with managing (1) special requests and (2) test results, (3) quality control and proficiency testing, (4) equipment acquisition and maintenance, (5) replacement of units lost to positive tests, (6) seasonal or geographic testing, and (7) health department interactions. All costs are mean values per apheresis PLT unit in USD ($/unit). The estimated test costs that could be eliminated are $71.76/unit and a decrease in transfusion reactions corresponds to $2.70/unit. Avoiding new tests (e.g., Babesia and dengue) amounts to $41.80/unit. Elimination of irradiation saves $8.50/unit, while decreased outdating with 7-day storage can be amortized to $16.89/unit. Total potential costs saved with PI is $141.65/unit. Costs are influenced by a variety of factors specific to institutions such as testing practices and the location in which such costs are incurred and careful analysis should be performed. Additional benefits, not quantified, include retention of some currently deferred donors and scheduling flexibility due to 7-day storage. While PI implementation will result in additional costs, there are also potential offsetting cost reductions, especially after 7-day storage licensing. © 2015 The Authors Transfusion published by Wiley Periodicals, Inc. on behalf of AABB.
NASA Technical Reports Server (NTRS)
Platt, R.
1998-01-01
This is the Performance Verification Report. the process specification establishes the requirements for the comprehensive performance test (CPT) and limited performance test (LPT) of the earth observing system advanced microwave sounding unit-A2 (EOS/AMSU-A2), referred to as the unit. The unit is defined on drawing 1356006.
Improvement for enhancing effectiveness of universal power system (UPS) continuous testing process
NASA Astrophysics Data System (ADS)
Sriratana, Lerdlekha
2018-01-01
This experiment aims to enhance the effectiveness of the Universal Power System (UPS) continuous testing process of the Electrical and Electronic Institute by applying work scheduling and time study methods. Initially, the standard time of testing process has not been considered that results of unaccurate testing target and also time wasting has been observed. As monitoring and reducing waste time for improving the efficiency of testing process, Yamazumi chart and job scheduling theory (North West Corner Rule) were applied to develop new work process. After the improvements, the overall efficiency of the process possibly increased from 52.8% to 65.6% or 12.7%. Moreover, the waste time could reduce from 828.3 minutes to 653.6 minutes or 21%, while testing units per batch could increase from 3 to 4 units. Therefore, the number of testing units would increase from 12 units up to 20 units per month that also contribute to increase of net income of UPS testing process by 72%.
Hunter, Oluwatobi O; George, Elisabeth L; Ren, Dianxu; Morgan, Douglas; Rosenzweig, Margaret; Klinefelter Tuite, Patricia
2017-06-01
To increase adherence with intensive care unit mobility by developing and implementing a mobility training program that addresses nursing barriers to early mobilisation. An intensive care unit mobility training program was developed, implemented and evaluated with a pre-test, immediate post-test and eight-week post-test. Patient mobility was tracked before and after training. A ten bed cardiac intensive care unit. The training program's efficacy was measured by comparing pre-test, immediate post-test and 8-week post-test scores. Patient mobilisation rates before and after training were compared. Protocol compliance was measured in the post training group. Nursing knowledge increased from pre-test to immediate post-test (p<0.0001) and pre-test to 8-week post-test (p<0.0001). Mean test scores decreased by seven points from immediate post-test (80±12) to 8-week post-test (73±14). Fear significantly decreased from pre-test to immediate post-test (p=0.03), but not from pre-test to 8-week post-test (p=0.06) or immediate post-test to 8-week post-test (p=0.46). Post training patient mobility rates increased although not significantly (p=0.07). Post training protocol compliance was 78%. The project successfully increased adherence with intensive care unit mobility and indicates that a training program could improve adoption of early mobility. Copyright © 2016 Elsevier Ltd. All rights reserved.
2010-10-27
John C. Stennis Space Center employees complete installation of a chemical steam generator (CSG) unit at the site's E-2 Test Stand. On Oct. 24, 2010. The unit will undergo verification and validation testing on the E-2 stand before it is moved to the A-3 Test Stand under construction at Stennis. Each CSG unit includes three modules. Steam generated by the nine CSG units that will be installed on the A-3 stand will create a vacuum that allows Stennis operators to test next-generation rocket engines at simulated altitudes up to 100,000 feet.
Development of action levels for MED/MPD skin-testing units in ultraviolet phototherapy
NASA Astrophysics Data System (ADS)
O'Connor, Una M.; O'Hare, Neil J.
2003-03-01
Ultraviolet (UV) Phototherapy is commonly used for treatment of skin diseases such as psoriasis and eczema. Treatment is carried out using UV phototherapy units, exposing all or part of the body for a certain exposure time. Prior to exposure in treatment units, an unaffected area of skin may be tested using UV skin-testing units in order to determine a suitable treatment regime. The exposure time at which barely perceptible erythema has developed is known as the Minimal Erythemal Dose (MED) for UVB therapy and Minimal Phototoxic Dose (MPD) for UVA therapy. This is used to determine the starting dose in the treatment regime. The presence of 'hotspots' and 'coldspots' in UV skin-testing units can result in inaccurate determination of MED/MPD. This could give rise to severe burns during treatment, or in a sub-optimal dose regime being used. Quality assurance protocols for UV phototherapy equipment have recently been developed and these protocols have highlighted the need for action levels for skin-testing units. An action level is a reference value, which is used to determine whether the difference in irradiance output level across a UV unit is acceptable. Current methodologies for skin-testing in Ireland have been characterised and errors introduced during testing have been estimated. Action levels have been developed based on analysis of errors and requirements of skin-testing.
Swanson, William H.; Horner, Douglas G.; Dul, Mitchell W.; Malinovsky, Victor E.
2014-01-01
Purpose To develop guidelines for engineering perimetric stimuli to reduce test-retest variability in glaucomatous defects. Methods Perimetric testing was performed on one eye for 62 patients with glaucoma and 41 age-similar controls on size III and frequency-doubling perimetry and three custom tests with Gaussian blob and Gabor sinusoid stimuli. Stimulus range was controlled by values for ceiling (maximum sensitivity) and floor (minimum sensitivity). Bland-Altman analysis was used to derive 95% limits of agreement on test and retest, and bootstrap analysis was used to test the hypotheses about peak variability. Results Limits of agreement for the three custom stimuli were similar in width (0.72 to 0.79 log units) and peak variability (0.22 to 0.29 log units) for a stimulus range of 1.7 log units. The width of the limits of agreement for size III decreased from 1.78 to 1.37 to 0.99 log units for stimulus ranges of 3.9, 2.7, and 1.7 log units, respectively (F = 3.23, P < 0.001); peak variability was 0.99, 0.54, and 0.34 log units, respectively (P < 0.01). For a stimulus range of 1.3 log units, limits of agreement were narrowest with Gabor and widest with size III stimuli, and peak variability was lower (P < 0.01) with Gabor (0.18 log units) and frequency-doubling perimetry (0.24 log units) than with size III stimuli (0.38 log units). Conclusions Test-retest variability in glaucomatous visual field defects was substantially reduced by engineering the stimuli. Translational Relevance The guidelines should allow developers to choose from a wide range of stimuli. PMID:25371855
Swanson, William H; Horner, Douglas G; Dul, Mitchell W; Malinovsky, Victor E
2014-09-01
To develop guidelines for engineering perimetric stimuli to reduce test-retest variability in glaucomatous defects. Perimetric testing was performed on one eye for 62 patients with glaucoma and 41 age-similar controls on size III and frequency-doubling perimetry and three custom tests with Gaussian blob and Gabor sinusoid stimuli. Stimulus range was controlled by values for ceiling (maximum sensitivity) and floor (minimum sensitivity). Bland-Altman analysis was used to derive 95% limits of agreement on test and retest, and bootstrap analysis was used to test the hypotheses about peak variability. Limits of agreement for the three custom stimuli were similar in width (0.72 to 0.79 log units) and peak variability (0.22 to 0.29 log units) for a stimulus range of 1.7 log units. The width of the limits of agreement for size III decreased from 1.78 to 1.37 to 0.99 log units for stimulus ranges of 3.9, 2.7, and 1.7 log units, respectively ( F = 3.23, P < 0.001); peak variability was 0.99, 0.54, and 0.34 log units, respectively ( P < 0.01). For a stimulus range of 1.3 log units, limits of agreement were narrowest with Gabor and widest with size III stimuli, and peak variability was lower ( P < 0.01) with Gabor (0.18 log units) and frequency-doubling perimetry (0.24 log units) than with size III stimuli (0.38 log units). Test-retest variability in glaucomatous visual field defects was substantially reduced by engineering the stimuli. The guidelines should allow developers to choose from a wide range of stimuli.
Test report: Electron-proton spectrometer qualification test unit, qualification test
NASA Technical Reports Server (NTRS)
Vincent, D. L.
1972-01-01
Qualification tests of the electron-proton spectrometer test unit are presented. The tests conducted were: (1) functional, (2) thermal/vacuum, (3) electromagnetic interference, (4) acoustic, (5) shock, (6) vibration, and (7) humidity. Results of each type of test are presented in the form of data sheets.
Code of Federal Regulations, 2014 CFR
2014-07-01
... requirements for importers who import gasoline into the United States by truck. 80.1349 Section 80.1349... FUELS AND FUEL ADDITIVES Gasoline Benzene Sampling, Testing and Retention Requirements § 80.1349 Alternative sampling and testing requirements for importers who import gasoline into the United States by...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-22
... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Software Unit Testing for Digital Computer Software...) is issuing for public comment draft regulatory guide (DG), DG-1208, ``Software Unit Testing for Digital Computer Software used in Safety Systems of Nuclear Power Plants.'' The DG-1208 is proposed...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-02
... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Software Unit Testing for Digital Computer Software... revised regulatory guide (RG), revision 1 of RG 1.171, ``Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants.'' This RG endorses American National Standards...
Principles of Technology. Units 1-10 Pilot Test Findings.
ERIC Educational Resources Information Center
Center for Occupational Research and Development, Inc., Waco, TX.
This document provides the findings of pilot tests of 10 units for an applied science course for high school vocational students. Each of the reports on the pilot tests of the Principles of Technology units contains information on procedures, methodology limitations, sample, the pretest/posttest instrument and results, student attitude results,…
29 CFR 1919.28 - Unit proof tests-cranes and gear accessory thereto.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 7 2010-07-01 2010-07-01 false Unit proof tests-cranes and gear accessory thereto. 1919.28... ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) GEAR CERTIFICATION Certification of Vessels: Tests and Proof Loads; Heat Treatment; Competent Persons § 1919.28 Unit proof tests—cranes and gear accessory thereto...
10 CFR 431.135 - Units to be tested.
Code of Federal Regulations, 2011 CFR
2011-01-01
... EQUIPMENT Automatic Commercial Ice Makers Test Procedures § 431.135 Units to be tested. For each basic model of automatic commercial ice maker selected for testing, a sample of sufficient size shall be selected...
NASA Astrophysics Data System (ADS)
Mosthaf, Klaus; Brauns, Bentje; Fjordbøge, Annika S.; Rohde, Magnus M.; Kerrn-Jespersen, Henriette; Bjerg, Poul L.; Binning, Philip J.; Broholm, Mette M.
2018-06-01
Limestone aquifers are of great interest as a drinking water resource in many countries. They often have a complex crushed and fractured geology, which makes the analysis and description of flow and transport processes in such aquifers a challenging task. In this study, the solute transport behavior including fracture-matrix interaction in hydrogeological units of a limestone aquifer in eastern Denmark was characterized by designing, conducting and interpreting six depth-specific tracer tests involving natural- and forced-gradient conditions with multiple tracers representing different diffusion properties. To determine flow parameters, the tracer tests were complemented by a comprehensive set of depth-specific borehole and hydraulic tests. Based on the tests, a new and stronger conceptual understanding was developed for the different aquifer units. The investigated limestone aquifer is composed of a glacially crushed unit and two fractured units, with calcarenitic and bryozoan limestone of similar hydraulic properties. Hydraulic tests revealed that the crushed unit has a lower hydraulic conductivity than the fractured limestone units, likely due to the crushed conditions with small limestone clusters and small-aperture fractures potentially filled with fine material. In the fractured limestone units, a distinct preferential flow and primary transport along major horizontal fractures was inferred from the tracer tests under forced-gradient conditions. The dominant horizontal fractures were identified on impeller flow logs and appear connected between wells, having an extent of up to several hundred meters. Connectivity between the aquifer units was investigated with a long-term pumping test and tracer tests, revealing restricted vertical flow and transport. A very pronounced hydraulic conductivity contrast between major fractures and matrix could also be inferred from the borehole and hydraulic tests, which is consistent with the findings from the tracer tests. The difference in the matrix diffusion behavior of the simultaneously injected tracers and a long tailing in the breakthrough curves revealed that matrix diffusion has a strong influence on the solute transport in the fractured limestone.
HEMP (high-altitude electromagnetic pulse) test and analysis of selected recloser-control units
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, T.K.; Sands, S.H.; Tesche, F.M.
A simulated HEMP test was performed on power line recloser-control units in the ARES facility during the month of October 1988. Two types of recloser-control units were tested: an electronic control unit presently in wide use in electric power distribution systems and a new microprocessor based unit presently being introduced to electric utilities. It was found that the ARES fields did not cause reproducible disruptive failure of the equipment. Minor upsets, which were considered to be non-disruptive to the recloser operation, were observed. The test results were compared to the results of an analysis from a previous study and itmore » is concluded that the probability of disruptive failure of field operating recloser-control units subjected to a nominal unclassified HEMP environment is small. 3 refs., 30 figs., 1 tab.« less
First results from quality assurance testing of MaPMTs for the LHCb RICH upgrade
NASA Astrophysics Data System (ADS)
Gambetta, S.; LHCb RICH Collaboration
2017-12-01
In 2019 the LHCb RICH detector will be upgraded to increase the read out rate from 1 MHz to 40 MHz. As a consequence, the current Hybrid Photon Detectors will have to be replaced. Multi-anode Photomultiplier Tubes (MaPMTs) from Hamamatsu with 64-channels will be used: the 1-in. R13742 and the 2-in. R13743 MaPMTs (custom modifications of the MaPMTs R11625 and R12699). Quality assurance testing of these MaPMTs using custom-developed readout electronics has started. We present the design and realisation of the test facilities to ensure consistency in testing and validation. A total of 3100 units of the R13742 and 450 units of the R13743 will be tested requiring high efficiency and reliability from the test stations. We report on the test programme and protocols, characterising the units and assuring compliance with specifications. First results of testing and detector characterisation will be presented, based on the pre-series production, comprising 54 units of R13742 and 20 units of R13743.
NASA Technical Reports Server (NTRS)
Hruby, R. J.; Bjorkman, W. S.
1977-01-01
Flight test results of the strapdown inertial reference unit (SIRU) navigation system are presented. The fault-tolerant SIRU navigation system features a redundant inertial sensor unit and dual computers. System software provides for detection and isolation of inertial sensor failures and continued operation in the event of failures. Flight test results include assessments of the system's navigational performance and fault tolerance.
Lucey, C
2006-11-01
This article briefly recounts the 21st July 2005, Blood Products Advisory Committee (BPAC) meeting concerning recommendations for management of donors and units testing positive for hepatitis B virus (HBV) DNA. The author attended the meeting. The United States Food and Drug Administration (FDA) web site was used for meeting materials, and handouts were collected at the meeting to provide narrative information. Two European experts assisted with HBV subject matter. The proceedings of the advisory committee, the issue briefing materials, and testing algorithms are presented. BPAC voted concurrence with the FDA algorithm for Management of Donors and Units Testing Positive for Hepatitis B Virus DNA.
Design of a Facility to Test the Advanced Stirling Radioisotope Generator Engineering Unit
NASA Technical Reports Server (NTRS)
Lewandowski, Edward J.; Schreiber, Jeffrey G.; Oriti, Salvatore M.; Meer, David W.; Brace, Michael H.; Dugala, Gina
2010-01-01
The Advanced Stirling Radioisotope Generator (ASRG), a high efficiency generator, is being considered for space missions. An engineering unit, the ASRG engineering unit (EU), was designed and fabricated by Lockheed Martin under contract to the Department of Energy. This unit is currently under extended operation test at the NASA Glenn Research Center (GRC) to generate performance data and validate the life and reliability predictions for the generator and the Stirling convertors. A special test facility was designed and built for the ASRG EU. This paper summarizes details of the test facility design, including the mechanical mounting, heat-rejection system, argon system, control systems, and maintenance. The effort proceeded from requirements definition through design, analysis, build, and test. Initial testing and facility performance results are discussed.
Charge-Control Unit for Testing Lithium-Ion Cells
NASA Technical Reports Server (NTRS)
Reid, Concha M.; Mazo, Michelle A.; Button, Robert M.
2008-01-01
A charge-control unit was developed as part of a program to validate Li-ion cells packaged together in batteries for aerospace use. The lithium-ion cell charge-control unit will be useful to anyone who performs testing of battery cells for aerospace and non-aerospace uses and to anyone who manufacturers battery test equipment. This technology reduces the quantity of costly power supplies and independent channels that are needed for test programs in which multiple cells are tested. Battery test equipment manufacturers can integrate the technology into their battery test equipment as a method to manage charging of multiple cells in series. The unit manages a complex scheme that is required for charging Li-ion cells electrically connected in series. The unit makes it possible to evaluate cells together as a pack using a single primary test channel, while also making it possible to charge each cell individually. Hence, inherent cell-to-cell variations in a series string of cells can be addressed, and yet the cost of testing is reduced substantially below the cost of testing each cell as a separate entity. The unit consists of electronic circuits and thermal-management devices housed in a common package. It also includes isolated annunciators to signal when the cells are being actively bypassed. These annunciators can be used by external charge managers or can be connected in series to signal that all cells have reached maximum charge. The charge-control circuitry for each cell amounts to regulator circuitry and is powered by that cell, eliminating the need for an external power source or controller. A 110-VAC source of electricity is required to power the thermal-management portion of the unit. A small direct-current source can be used to supply power for an annunciator signal, if desired.
Flight test results of the strapdown hexad inertial reference unit (SIRU). Volume 2: Test report
NASA Technical Reports Server (NTRS)
Hruby, R. J.; Bjorkman, W. S.
1977-01-01
Results of flight tests of the Strapdown Inertial Reference Unit (SIRU) navigation system are presented. The fault tolerant SIRU navigation system features a redundant inertial sensor unit and dual computers. System software provides for detection and isolation of inertial sensor failures and continued operation in the event of failures. Flight test results include assessments of the system's navigational performance and fault tolerance. Performance shortcomings are analyzed.
Unit Testing for the Application Control Language (ACL) Software
NASA Technical Reports Server (NTRS)
Heinich, Christina Marie
2014-01-01
In the software development process, code needs to be tested before it can be packaged for release in order to make sure the program actually does what it says is supposed to happen as well as to check how the program deals with errors and edge cases (such as negative or very large numbers). One of the major parts of the testing process is unit testing, where you test specific units of the code to make sure each individual part of the code works. This project is about unit testing many different components of the ACL software and fixing any errors encountered. To do this, mocks of other objects need to be created and every line of code needs to be exercised to make sure every case is accounted for. Mocks are important to make because it gives direct control of the environment the unit lives in instead of attempting to work with the entire program. This makes it easier to achieve the second goal of exercising every line of code.
NASA Astrophysics Data System (ADS)
Latimer, T. W.; Rinehart, G. H.
1992-05-01
This report covers progress on the Milliwatt Generator Project from April 1986 through March 1988. Activities included fuel processing and characterization, production of heat sources, fabrication of pressure-burst test units, compatibility studies, impact testing, and examination of surveillance units. The major task of the Los Alamos Milliwatt Generator Project is to fabricate MC2893A heat sources (4.0 W) for MC2730A radioisotope thermoelectric generators (RTG's) and MC3599 heat sources (4.5 W) for MC3500 RTG's. The MWG Project interfaces with the following contractors: Sandia National Laboratories, Albuquerque (designer); E.I. du Pont de Nemours and Co. (Inc.), Savannah River Plant (fuel); Monsanto Research Corporation, Mound Facility (metal hardware); and General Electric Company, Neutron Devices Department (RTG's). In addition to MWG fabrication activities, Los Alamos is involved in (1) fabrication of pressure-burst test units, (2) compatibility testing and evaluation, (3) examination of surveillance units, and (4) impact testing and subsequent examination of compatibility and surveillance units.
30 CFR 7.67 - Construction test.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Construction test. 7.67 Section 7.67 Mineral... MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Multiple-Shot Blasting Units § 7.67 Construction test. The constuction test is to be performed on the blasting unit subsequent to the output energy test of...
30 CFR 7.67 - Construction test.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Construction test. 7.67 Section 7.67 Mineral... MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Multiple-Shot Blasting Units § 7.67 Construction test. The constuction test is to be performed on the blasting unit subsequent to the output energy test of...
30 CFR 7.67 - Construction test.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Construction test. 7.67 Section 7.67 Mineral... MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Multiple-Shot Blasting Units § 7.67 Construction test. The constuction test is to be performed on the blasting unit subsequent to the output energy test of...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Newcomer, Darrell R.
2007-09-30
Slug-test results obtained from single and multiple, stress-level slug tests conducted during drilling and borehole advancement provide detailed hydraulic conductivity information at two Hanford Site Operable Unit (OU) ZP-1 test well locations. The individual test/depth intervals were generally sited to provide hydraulic-property information within the upper ~10 m of the unconfined aquifer (i.e., Ringold Formation, Unit 5). These characterization results complement previous and ongoing drill-and-test characterization programs at surrounding 200-West and -East Area locations (see Figure S.1).
Aviation System Analysis Capability (ASAC) Quick Response System (QRS) Test Report
NASA Technical Reports Server (NTRS)
Roberts, Eileen; Villani, James A.; Ritter, Paul
1997-01-01
This document is the Aviation System Analysis Capability (ASAC) Quick Response System (QRS) Test Report. The purpose of this document is to present the results of the QRS unit and system tests in support of the ASAC QRS development effort. This document contains an overview of the project background and scope, defines the QRS system and presents the additions made to the QRS this year, explains the assumptions, constraints, and approach used to conduct QRS Unit and System Testing, and presents the schedule used to perform QRS Testing. The document also presents an overview of the Logistics Management Institute (LMI) Test Facility and testing environment and summarizes the QRS Unit and System Test effort and results.
10 CFR 431.295 - Units to be tested.
Code of Federal Regulations, 2011 CFR
2011-01-01
... EQUIPMENT Refrigerated Bottled or Canned Beverage Vending Machines Test Procedures § 431.295 Units to be tested. For each basic model of refrigerated bottled or canned beverage vending machine selected for...
Status of Hollow Cathode Heater Development for the Space Station Plasma Contactor
NASA Technical Reports Server (NTRS)
Soulas, George C.
1994-01-01
A hollow cathode-based plasma contactor has been selected for use on the Space Station. During the operation of the plasma contactor, the hollow cathode heater will endure approximately 12000 thermal cycles. Since a hollow cathode heater failure would result in a plasma contactor failure, a hollow cathode heater development program was established to produce a reliable heater. The development program includes the heater design, process documents for both heater fabrication and assembly, and heater testing. The heater design was a modification of a sheathed ion thruster cathode heater. Heater tests included testing of the heater unit alone and plasma contactor and ion thruster testing. To date, eight heaters have been or are being processed through heater unit testing, two through plasma contactor testing and three through ion thruster testing, all using direct current power supplies. Comparisons of data from heater unit performance tests before cyclic testing, plasma contactor tests, and ion thruster tests at the ignition input current level show the average deviation of input power and tube temperature near the cathode tip to be +/-0.9 W and +/- 21 C, respectively. Heater unit testing included cyclic testing to evaluate reliability under thermal cycling. The first heater, although damaged during assembly, completed 5985 ignition cycles before failing. Four additional heaters successfully completed 6300, 6300, 700, and 700 cycles. Heater unit testing is currently ongoing for three heaters which have to date accumulated greater than 7250, greater than 5500, and greater than 5500 cycles, respectively.
Test report: Shock test of the electron/proton spectrometer structural test unit
NASA Technical Reports Server (NTRS)
Vincent, D. L.
1972-01-01
A shock test of the electron-proton spectrometer structural test unit was conducted. The purpose of the shock test was to verify the structural integrity of the electron-spectrometer design and to obtain data on the shock response of the electronics and electronic housing. The test equipment is described and typical shock response data are provided.
14 CFR 120.123 - Drug testing outside the territory of the United States.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Drug testing outside the territory of the... OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.123 Drug testing outside the territory of the United States. (a) No part of the testing process (including specimen collection...
14 CFR 120.123 - Drug testing outside the territory of the United States.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Drug testing outside the territory of the... OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.123 Drug testing outside the territory of the United States. (a) No part of the testing process (including specimen collection...
14 CFR 120.123 - Drug testing outside the territory of the United States.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Drug testing outside the territory of the... OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.123 Drug testing outside the territory of the United States. (a) No part of the testing process (including specimen collection...
14 CFR 120.123 - Drug testing outside the territory of the United States.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Drug testing outside the territory of the... OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.123 Drug testing outside the territory of the United States. (a) No part of the testing process (including specimen collection...
14 CFR 120.123 - Drug testing outside the territory of the United States.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Drug testing outside the territory of the... OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.123 Drug testing outside the territory of the United States. (a) No part of the testing process (including specimen collection...
Tensile testing of thin-film microstructures
NASA Astrophysics Data System (ADS)
Greek, Staffan; Johansson, Stefan A. I.
1997-09-01
The mechanical properties of thin film microstructures depend on size and shape and on the film manufacturing process. Hence, the test structures that are used to measure mechanical properties should have dimensions of the same order of magnitude as an application structure. The microstructures are easily monitored in a scanning electron microscope (SEM), but to be handled and tested in situ a micromanipulator was developed. The parts of the micromanipulator essential to the tests are two independently moveable tables driven by electric motors. The test structures and a testing unit are mounted on the tables. A testing unit was designed to measure force and displacement with high resolution. The testing unit consists of an arm actuated by a piezoelectric element and equipped with a probe. An optical encoder measures the movement of the arm, while strain gauges measure the force in the arm. Test structures consist typically of a released beam fixed at one end with a ring at the other. The micromanipulator is used to position the probe of the testing unit in the ring. The testing unit then executed a tensile test of the beam. Test structures of polysilicon films produced under various process conditions were used to verify the possibility of measuring Young's modulus with an accuracy of +/- 5 percent, as well as fracture strength.Young's modulus is calculated using the difference in elongation for different beam lengths. The fracture strength of the beams was evaluated with Weibull statistics.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-26
... Plant, Unit 4; Inspections, Tests, Analyses, and Acceptance Criteria AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria completion. SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) staff has determined that the inspections, tests...
NASA Technical Reports Server (NTRS)
Platt, R.
1999-01-01
This is the Performance Verification Report, Final Comprehensive Performance Test (CPT) Report, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). This specification establishes the requirements for the CPT and Limited Performance Test (LPT) of the AMSU-1A, referred to here in as the unit. The sequence in which the several phases of this test procedure shall take place is shown.
Code of Federal Regulations, 2011 CFR
2011-04-01
... activity outside the United States; 45 hour and 7-day work test. 404.417 Section 404.417 Employees... activity outside the United States; 45 hour and 7-day work test. (a) Deductions because of individual's... on. Effective May 1983, a 45-hour work test applies before a benefit deduction is made for the non...
Code of Federal Regulations, 2010 CFR
2010-04-01
... activity outside the United States; 45 hour and 7-day work test. 404.417 Section 404.417 Employees... activity outside the United States; 45 hour and 7-day work test. (a) Deductions because of individual's... on. Effective May 1983, a 45-hour work test applies before a benefit deduction is made for the non...
Criterion Referenced Tests to Accompany "Artes Latinae," Level 1, Book 1. Tentative Edition.
ERIC Educational Resources Information Center
Masciantonio, Rudolph
These tests are designed to measure the achievement of each pupil at the approximate midpoint of each unit in "Artes Latinae," Level 1, Book 1. They were produced in response to the need expressed by many teachers to provide a means of more frequent evaluation of pupil progress. Tests for 13 units are provided. They supplement the unit tests…
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 12 2011-07-01 2009-07-01 true Requirements for Performance Tests for Organic HAP Emissions From Catalytic Reforming Units 18 Table 18 to Subpart UUU of Part 63 Protection of... Units Pt. 63, Subpt. UUU, Table 18 Table 18 to Subpart UUU of Part 63—Requirements for Performance Tests...
Testing for unit root bilinearity in the Brazilian stock market
NASA Astrophysics Data System (ADS)
Tabak, Benjamin M.
2007-11-01
In this paper a simple test for detecting bilinearity in a stochastic unit root process is used to test for the presence of nonlinear unit roots in Brazilian equity shares. The empirical evidence for a set of 53 individual stocks, after adjusting for GARCH effects, suggests that for more than 66%, the hypothesis of unit root bilinearity is accepted. Therefore, the dynamics of Brazilian share prices is in conformity with this type of nonlinearity. These nonlinearities in spot prices may emerge due to the sophistication of the derivatives market.
Pre-production Test Report for Transformer Abort Sensing and Control Unit.
The purpose of the report is to describe the test equipment and procedure required for the pre-production testing of a transformer, pressure switch excitation, abort sensing and control unit. (Author)
Needleman, Jack; Pearson, Marjorie L; Upenieks, Valda V; Yee, Tracy; Wolstein, Joelle; Parkerton, Melissa
2016-02-01
Process improvement stresses the importance of engaging frontline staff in implementing new processes and methods. Yet questions remain on how to incorporate these activities into the workday of hospital staff or how to create and maintain its commitment. In a 15-month American Organization of Nurse Executives collaborative involving frontline medical/surgical staff from 67 hospitals, Transforming Care at the Bedside (TCAB) was evaluated to assess whether participating units successfully implemented recommended change processes, engaged staff, implemented innovations, and generated support from hospital leadership and staff. In a mixed-methods analysis, multiple data sources, including leader surveys, unit staff surveys, administrative data, time study data, and collaborative documents were used. All units reported establishing unit-based teams, of which >90% succeeded in conducting tests of change, with unit staff selecting topics and making decisions on adoption. Fifty-five percent of unit staff reported participating in unit meetings, and 64%, in tests of change. Unit managers reported substantial increase in staff support for the initiative. An average 36 tests of change were conducted per unit, with 46% of tested innovations sustained, and 20% spread to other units. Some 95% of managers and 97% of chief nursing officers believed that the program had made unit staff more likely to initiate change. Among staff, 83% would encourage adoption of the initiative. Given the strong positive assessment of TCAB, evidence of substantial engagement of staff in the work, and the high volume of innovations tested, implemented, and sustained, TCAB appears to be a productive model for organizing and implementing a program of frontline-led improvement.
The fungicide mancozeb induces toxic effects on mammalian granulosa cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paro, Rita; Tiboni, Gian Mario; Buccione, Roberto
2012-04-15
The ethylene-bis-dithiocarbamate mancozeb is a widely used fungicide with low reported toxicity in mammals. In mice, mancozeb induces embryo apoptosis, affects oocyte meiotic spindle morphology and impairs fertilization rate even when used at very low concentrations. We evaluated the toxic effects of mancozeb on the mouse and human ovarian somatic granulosa cells. We examined parameters such as cell morphology, induction of apoptosis, and p53 expression levels. Mouse granulosa cells exposed to mancozeb underwent a time- and dose-dependent modification of their morphology, and acquired the ability to migrate but not to proliferate. The expression level of p53, in terms of mRNAmore » and protein content, decreased significantly in comparison with unexposed cells, but no change in apoptosis was recorded. Toxic effects could be attributed, at least in part, to the presence of ethylenthiourea (ETU), the main mancozeb catabolite, which was found in culture medium. Human granulosa cells also showed dose-dependent morphological changes and reduced p53 expression levels after exposure to mancozeb. Altogether, these results indicate that mancozeb affects the somatic cells of the mammalian ovarian follicles by inducing a premalignant-like status, and that such damage occurs to the same extent in both mouse and human GC. These results further substantiate the concept that mancozeb should be regarded as a reproductive toxicant. Highlights: ► The fungicide mancozeb affects oocyte spindle morphology and fertilization rate. ► We investigated the toxic effects of mancozeb on mouse and human granulosa cells. ► Granulosa cells modify their morphology and expression level of p53. ► Mancozeb induces a premalignant-like status in exposed cells.« less
Kouadio, Koffi Isidore; Clement, Peter; Bolongei, Josephus; Tamba, Alpha; Gasasira, Alex Ntale; Warsame, Abdihamid; Okeibunor, Joseph Chukwudi; Ota, Martin Okechukwu; Tamba, Boima; Gumede, Nicksy; Shaba, Keith; Poy, Alain; Salla, Mbaye; Mihigo, Richard; Nshimirimana, Deo
2015-05-06
Ebola Virus Disease (EVD) outbreak was confirmed in Liberia on March 31st 2014. A response comprising of diverse expertise was mobilized and deployed to the country to contain transmission of Ebola and give relief to a people already impoverished from protracted civil war. This paper describes the epidemiological and surveillance response to the EVD outbreak in Lofa County in Liberia from March to September 2014. Five of the 6 districts of Lofa were affected. The most affected districts were Voinjama/Guardu Gbondi and Foya. By 26th September, 2014, a total of 619 cases, including 19.4% probable cases, 20.3% suspected cases and 44.2% confirmed cases were recorded by the Ebola Emergency Response Team (EERT) of Lofa County. Adults (20-50 years) were the most affected. Overall fatality rate was 53.3%. Twenty two (22) cases were reported among the Health Care Workers with a fatality rate of 81.8%. Seventy eight percent (78%) of the contacts successfully completed 21 days follow-up while 134 (6.15%) that developed signs and symptoms of EVD were referred to the ETU in Foya. The contributions of the weak health systems as well as socio-cultural factors in fueling the epidemic are highlighted. Importantly, the lessons learnt including the positive impact of multi-sectorial and multidisciplinary and coordinated response led by the government and community. Again, given that the spread of infectious disease can be considered a security threat every effort has to put in place to strengthen the health systems in developing countries including the International Health Regulation (IHR)'s core capacities. Key words: Ebola virus disease, outbreak, epidemiology and surveillance, socio-cultural factors, health system, West Africa.
Environmental Test Screening Procedure
NASA Technical Reports Server (NTRS)
Zeidler, Janet
2000-01-01
This procedure describes the methods to be used for environmental stress screening (ESS) of the Lightning Mapper Sensor (LMS) lens assembly. Unless otherwise specified, the procedures shall be completed in the order listed, prior to performance of the Acceptance Test Procedure (ATP). The first unit, S/N 001, will be subjected to the Qualification Vibration Levels, while the remainder will be tested at the Operational Level. Prior to ESS, all units will undergo Pre-ESS Functional Testing that includes measuring the on-axis and plus or minus 0.95 full field Modulation Transfer Function and Back Focal Length. Next, all units will undergo ESS testing, and then Acceptance testing per PR 460.
Chemical analysis kit for the presence of explosives
Eckels, Joel Del [Livermore, CA; Nunes,; Peter, J [Danville, CA; Alcaraz, Armando [Livermore, CA; Whipple, Richard E [Livermore, CA
2011-05-10
A tester for testing for explosives associated with a test location comprising a first explosives detecting reagent; a first reagent holder, the first reagent holder containing the first explosives detecting reagent; a second explosives detecting reagent; a second reagent holder, the second reagent holder containing the second explosives detecting reagent; a sample collection unit for exposure to the test location, exposure to the first explosives detecting reagent, and exposure to the second explosives detecting reagent; and a body unit containing a heater for heating the sample collection unit for testing the test location for the explosives.
Practical Business: Instructor/Student Guide.
ERIC Educational Resources Information Center
Napier, Deedee Stocker
Ten units on practical business are presented in this instructor and student guide. Each instructional unit contains objectives, suggested activities, information sheets, assignment sheets, transparency master, a test, and test answers. Unit topics are (1) before you buy (comparative shopping and wise purchasing techniques); (2) when things go…
Identification of the Parameters of Menétrey -Willam Failure Surface of Calcium Silicate Units
NASA Astrophysics Data System (ADS)
Radosław, Jasiński
2017-10-01
The identification of parameters of Menétrey-Willamsurface made of concrete, masonry or autoclaved aerated concrete is not complicated. It is much more difficult to identify failure parameters of masonry units with cavities. This paper describes the concept of identifying the parameters of Menétrey-Willam failure surface (M-W-3) with reference to masonry units with vertical cavities. The M-W-3 surface is defined by uniaxial compressive strength fc, uniaxial tensile strength ft and eccentricity of elliptical function e. A test stand was built to identify surface parameters. It was used to test behaviour of masonry units under triaxial stress and conduct tests on whole masonry units in the uniaxial state. Results from tests on tens of silicate masonry units are presented in the Haigh-Westergaard (H-W) space. Statistical analyses were used to identify the shape of surface meridian, and then to determine eccentricity of the elliptical function.
Auxiliary propulsion system flight package
NASA Technical Reports Server (NTRS)
Collett, C. R.
1987-01-01
Hughes Aircraft Company developed qualified and integrated flight, a flight test Ion Auxiliary Propulsion System (IAPS), on an Air Force technology satellite. The IAPS Flight Package consists of two identical Thruster Subsystems and a Diagnostic Subsystem. Each thruster subsystem (TSS) is comprised of an 8-cm ion Thruster-Gimbal-Beam Shield Unit (TGBSU); Power Electronics Unit; Digital Controller and Interface Unit (DCIU); and Propellant Tank, Valve and Feed Unit (PTVFU) plus the requisite cables. The Diagnostic Subsystem (DSS) includes four types of sensors for measuring the effect of the ion thrusters on the spacecraft and the surrounding plasma. Flight qualifications of IAPS, prior to installation on the spacecraft, consisted of performance, vibration and thermal-vacuum testing at the unit level, and thermal-vacuum testing at the subsystem level. Mutual compatibility between IAPS and the host spacecraft was demonstrated during a series of performance and environmental tests after the IAPS Flight Package was installed on the spacecraft. After a spacecraft acoustic test, performance of the ion thrusters was reverified by removing the TGBSUs for a thorough performance test at Hughes Research Laboratories (HRL). The TGBSUs were then reinstalled on the spacecraft. The IAPS Flight Package is ready for flight testing when Shuttle flights are resumed.
Testing the system detection unit for measuring solid minerals bulk density
NASA Astrophysics Data System (ADS)
Voytyuk, I. N.; Kopteva, A. V.
2017-10-01
The paper provides a brief description of the system for measuring flux per volume of solid minerals via example of mineral coal. The paper discloses the operational principle of the detection unit. The paper provides full description of testing methodology, as well as practical implementation of the detection unit testing. This paper describes the removal of two data arrays via the channel of scattered anddirect radiation for the detection units of two generations. This paper describes Matlab software to determine the statistical characteristics of the studied objects. The mean value of pulses per cycles, and pulse counting inaccuracy relatively the mean value were determined for the calculation of the stability account of the detection units.
Whole blood coagulation analyzers.
1997-08-01
Whole blood Coagulation analyzers (WBCAs) are widely used point-of-care (POC) testing devices found primarily in cardiothoracic surgical suites and cardia catheterization laboratories. Most of these devices can perform a number of coagulation tests that provide information about a patient's blood clotting status. Clinicians use the results of the WBCA tests, which are available minutes after applying a blood sample, primarily to monitor the effectiveness of heparin therapy--an anticoagulation therapy used during cardiopulmonary bypass (CPB) surgery, angioplasty, hemodialysis, and other clinical procedures. In this study we evaluated five WBCAs from four suppliers. Our testing focused on the applications for which WBCAs are primarily used: Monitoring moderate to high heparin levels, as would be required, for example, during CPB are angioplasty. For this function, WCBAs are typically used to perform an activated clotting time (ACT) test or, as one supplier refers to its test, a heparin management test (HMT). All models included in this study offered an ACT test or an HMT. Monitoring low heparin levels, as would be required, for example,during hemodialysis. For this function, WBCAs would normally be used to perform either a low-range ACT (LACT) test or a whole blood activated partial thromboplastin time (WBAPTT) test. Most of the evaluated units could perform at least one of these tests; one unit did not offer either test and was therefore not rated for this application. We rated and ranked each evaluated model separately for each of these two applications. In addition, we provided a combined rating and ranking that considers the units' appropriateness for performing both application. We based our conclusions on a unit's performance and humans factor design, as determined by our testing, and on its five-year life-cycle cost, as determined by our net present value (NPV) analysis. While we rated all evaluated units acceptable for each appropriate category, we did identify some significant differences that enabled us to rank the units in order of preference. We have included a Selection, Purchasing, and use guide at the end of this study to help facilities identify the unit that will best meet their needs.
Development of a new photocatalytic oxidation air filter for aircraft cabin.
Ginestet, A; Pugnet, D; Rowley, J; Bull, K; Yeomans, H
2005-10-01
A new photocatalytic oxidation air filter (PCO unit) has been designed for aircraft cabin applications. The PCO unit is designed as a regenerable VOC removal system in order to improve the quality of the recirculated air entering the aircraft cabin. The PCO was designed to be a modular unit, with four UV lamps sandwiched between two interchangeable titanium dioxide coated panels. Performances of the PCO unit has been measured in a single pass mode test rig in order to show the ability of the unit to decrease the amount of VOCs (toluene, ethanol, and acetone) entering it (VOCs are fed separately), and in a multipass mode test rig in order to measure the ability of the unit to clean the air of an experimental room polluted with the same VOCs (fed separately). Triangular cell panels have been chosen instead of the wire mesh panels because they have higher efficiency. The efficiency of the PCO unit depends on the type of VOCs that challenges it, toluene being the most difficult one to oxidise. The efficiency of the PCO unit decreases when the air flow rate increases. The multipass mode test results show that the VOCs are oxidized but additional testing time would be necessary in order to show if they can be fully oxidized. The intermediate reaction products are mainly acetaldehyde and formaldehyde whose amount depends on the challenge VOC. The intermediate reaction products are also oxidized and additional testing time would be necessary in order to show if they can be fully oxidized. The development of this new photocatalytic air filter is still going on. The VOC/odor removing adsorbers are available for only a small proportion of aircraft currently in service. The photocatalytic oxidation (PCO) technique has appeared to be a promising solution to odors problems met in aircraft. This article reports the test results of a new photocatalytic oxidation air filter (PCO unit) designed for aircraft cabin applications. The overall efficiency of the PCO unit is function of the compound (toluene, ethanol, and acetone) that challenges the unit and toluene appears to be the most difficult compound to oxidize. Test results have shown the influence of the design of the PCO unit, the air flow rate and the type of UV on the efficiency of the PCO unit. The results obtained in this study represent a first attempt on the way to design a filter for VOC removal in cabin aircraft applications. The PCO technique used by the tested prototype unit is able to partially oxidized the challenge VOCs but one has to be aware that some harmful intermediate reaction products (mainly formaldehyde and acetaldehyde) are produced during the oxidation process before being partially oxidized too.
General test plan redundant sensor strapdown IMU evaluation program
NASA Technical Reports Server (NTRS)
Hartwell, T.; Irwin, H. A.; Miyatake, Y.; Wedekind, D. E.
1971-01-01
The general test plan for a redundant sensor strapdown inertial measuring unit evaluation program is presented. The inertial unit contains six gyros and three orthogonal accelerometers. The software incorporates failure detection and correction logic and a land vehicle navigation program. The principal objective of the test is a demonstration of the practicability, reliability, and performance of the inertial measuring unit with failure detection and correction in operational environments.
Light-emitting device test systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCord, Mark; Brodie, Alan; George, James
Light-emitting devices, such as LEDs, are tested using a photometric unit. The photometric unit, which may be an integrating sphere, can measure flux, color, or other properties of the devices. The photometric unit may have a single port or both an inlet and outlet. Light loss through the port, inlet, or outlet can be reduced or calibrated for. These testing systems can provide increased reliability, improved throughput, and/or improved measurement accuracy.
Particulate Matter Stack Emission Compliance Test Procedure for Fuel Burning Units.
ERIC Educational Resources Information Center
West Virginia Air Pollution Control Commission, Charleston.
This publication details the particulate matter emissions test procedure that is applicable for conducting compliance tests for fuel burning units required to be tested under Sub-section 7 of Regulation II (1972) as established by the state of West Virginia Air Pollution Control Commission. The testing procedure is divided into five parts:…
Collaborative Test Reviews: Student Performance
ERIC Educational Resources Information Center
Bhatia, Anuradha; Makela, Carole J.
2010-01-01
A group study method proved helpful in improving senior-level students' performance on unit tests through collaborative learning. Students of a History of Textiles course voluntarily attended study sessions to review course content and prepare for unit tests. The students who attended the group reviews scored better on tests than those who did…
10 CFR 429.11 - General sampling requirements for selecting units to be tested.
Code of Federal Regulations, 2012 CFR
2012-01-01
... tested. 429.11 Section 429.11 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION CERTIFICATION, COMPLIANCE, AND ENFORCEMENT FOR CONSUMER PRODUCTS AND COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.11 General sampling requirements for selecting units to be tested. (a) When testing of covered products or...
Design assessment of a 150 kWt CFBC Test Unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Batu, A.; Selcuk, N.; Kulah, G.
2010-04-15
For clean and efficient energy generation from coal, the most suitable technology known to date is 'Fluidized Bed Combustion' technology. Applications of circulating fluidized bed (CFB) combustion technology have been steadily increasing in both capacity and number over the past decade. Designs of these units have been based on the combustion tests carried out in pilot scale facilities to determine the combustion and desulfurization characteristics of coal and limestone reserves in CFB conditions. Similarly, utilization of Turkish lignites in CFB boilers necessitates adaptation of CFB combustion technology to these resources. However, the design of these test units are not basedmore » on firing coals with high ash, volatile matter and sulfur contents like Turkish lignites. For this purpose, a 150 kWt CFB combustor test unit is designed and constructed in Chemical Engineering Department of Middle East Technical University, based on the extensive experience acquired at the existing 0.3 MWt Bubbling Atmospheric Fluidized Bed Combustor (AFBC) Test Rig. Following the commissioning tests, a combustion test is carried out for investigation of combustion characteristics of Can lignite in CFB conditions and for assessment of the design of test unit. Comparison of the design outputs with experimental results reveals that most of the predictions and assumptions have acceptable agreement with the operating conditions. In conclusion, the performance of 150 kWt CFBC Test Unit is found to be satisfactory to be utilized for the long term research studies on combustion and desulfurization characteristics of indigenous lignite reserves in circulating fluidized bed combustors. (author)« less
2012-11-06
NASA engineers test a chemical steam generator (CSG) unit on the E-2 Test Stand at John C. Stennis Space Center on Nov. 6. The test was one of 27 conducted in Stennis' E Test Complex the week of Nov. 5. Twenty-seven CSG units will be used on the new A-3 Test Stand at Stennis to produce a vacuum that allows testing of engines at simulated altitudes up to 100,000 feet.
NASA Technical Reports Server (NTRS)
Van Dyke, Michael B.
2013-01-01
Present preliminary work using lumped parameter models to approximate dynamic response of electronic units to random vibration; Derive a general N-DOF model for application to electronic units; Illustrate parametric influence of model parameters; Implication of coupled dynamics for unit/board design; Demonstrate use of model to infer printed wiring board (PWB) dynamics from external chassis test measurement.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Sulfur Oxides 32 Table 32 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION...: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 32 Table 32 to Subpart UUU of Part 63—Requirements for Performance Tests for HAP Emissions From Sulfur...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Sulfur Oxides 32 Table 32 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 32 Table 32 to Subpart UUU of Part 63—Requirements for Performance Tests for HAP Emissions From...
Code of Federal Regulations, 2010 CFR
2010-07-01
...) for Carbon Monoxide (CO) 11 Table 11 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 11 Table 11 to Subpart UUU of Part 63—Requirements for Performance Tests for Organic HAP Emissions...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Sulfur Oxides 32 Table 32 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 32 Table 32 to Subpart UUU of Part 63—Requirements for Performance Tests for HAP Emissions From...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Sulfur Oxides 32 Table 32 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 32 Table 32 to Subpart UUU of Part 63—Requirements for Performance Tests for HAP Emissions From...
Code of Federal Regulations, 2011 CFR
2011-07-01
...) for Carbon Monoxide (CO) 11 Table 11 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 11 Table 11 to Subpart UUU of Part 63—Requirements for Performance Tests for Organic HAP Emissions...
Spacelab interface development test, volume 1, sections 1-6
NASA Technical Reports Server (NTRS)
Harris, L. H.
1979-01-01
Data recorded during the following tests is presented: pulse coded modulator master unit to Spacelab (S/L) interface, master timing unit to S/L interface, multiplexer-demultiplexer/serial input-output to S/L interface, and special tests.
NASA Technical Reports Server (NTRS)
Pines, D.
1998-01-01
Two Flight Model AMSU-A Phase Locked Oscillators (P/N 1348360-1, S/Ns F03 and F04) have been tested per AES Test Procedure AE-26758. The tests included vibration testing, thermal cycle testing, AM/FM Noise testing, and full functional testing. EMI/REO 2 Testing was not performed. (See test data for S/N F01). Both AMSU-A Phase Locked Oscillators satisfactorily passed all performance requirements of the AE-26633 Product specification. During thermal cycling of PLO serial number F03, the oven and data logger momentarily lost power, including a loss of data. The unit did not experience any thermal stress. TAR 003134 describes the corrective action. Prior to testing PLO serial number FO4, power was applied to the unit. (+15v,-15v) the unit did not display the proper phase lock. Upon test equipment check out a connector was found to be defective. TAR 003133 describes the corrective action. After completion of testing of PLO serial number F04 was installed into Receiver Assembly F02. Upon testing F02 Receiver Assembly the unit was found not to phase lock at ambient temperature. Removal of PLO Assembly F04 was required. R2 was the real issue. Solithane was secondary. Troubleshooting revealed excessive solithane on inner PLL Assembly cover inhibiting optimum grounding. Also, R2 was reselected which increased the lock range from -30 C to +60 C. TAR 002737 describes the corrective action.
NASA Technical Reports Server (NTRS)
Balch, D. T.; Saccullo, A.; Sheehy, T. W.
1983-01-01
To assist in identifying and quantifying the relevant parameters associated with the complex topic of main rotor/fuselage/tail rotor interference, a model scale hover test was conducted in the Model Rotor Hover Facility. The test was conducted using the basic model test rig, fuselage skins to represent a UH-60A BLACK HAWK helicopter, 4 sets of rotor blades of varying geometry (i.e., twist, airfoils and solidity) and a model tail rotor that could be relocated to give changes in rotor clearance (axially, laterally, and vertically), can't angle and operating model (pusher or tractor). The description of the models and the tests, data analysis and summary (including plots) are included. The customary system of units gas used for principal measurements and calculations. Expressions in both SI units and customary units are used with the SI units stated first and the customary units afterwords, in parenthesis.
Summary of Aquifer Test Data for Arkansas - 1940-2006
Pugh, Aaron L.
2008-01-01
As demands on Arkansas's ground water continue to increase, decision-makers need all available information to ensure the sustainability of this important natural resource. From 1940 through 2006, the U.S. Geological Survey has conducted over 300 aquifer tests in Arkansas. Much of these data never have been published. This report presents the results from 206 of these aquifer tests from 21 different hydrogeologic units spread across 51 Arkansas counties. Ten of the hydrogeologic units are within the Atlantic Plain of Arkansas and consist mostly of unconsolidated and semi-consolidated deposits. The remaining 11 units are within the Interior Highlands consisting mainly of consolidated rock. Descriptive statistics are reported for each hydrologic unit with two or more tests, including the mean, minimum, median, maximum and standard deviation values for specific capacity, transmissivity, hydraulic conductivity, and storage coefficient. Hydraulic conductivity values for the major water-bearing hydrogeologic units are estimated because few conductivity values are recorded in the original records. Nearly all estimated hydraulic conductivity values agree with published hydraulic conductivity values based on the hydrogeologic unit material types. Similarly, because few specific capacity values were available in the original aquifer test records, specific capacity values are estimated for individual wells.
Dapia, Irene; Tong, Hoi Y.; Arias, Pedro; Muñoz, Mario; Tenorio, Jair; Hernández, Rafael; García García, Irene; Gordo, Gema; Ramírez, Elena; Frías, Jesús; Lapunzina, Pablo; Carcas, Antonio J.
2017-01-01
Abstract In 2014, we established a pharmacogenetics unit with the intention of facilitating the integration of pharmacogenetic testing into clinical practice. This unit was centered around two main ideas: i) individualization of clinical recommendations, and ii) preemptive genotyping in risk populations. Our unit is based on the design and validation of a single nucleotide polymorphism (SNP) microarray, which has allowed testing of 180 SNPs associated with drug response (PharmArray), and clinical consultation regarding the results. Herein, we report our experience in integrating pharmacogenetic testing into our hospital and we present the results of the 2,539 pharmacogenetic consultation requests received over the past 3 years in our unit. The results demonstrate the feasibility of implementing pharmacogenetic testing in clinical practice within a national health system. PMID:29193749
Indigenous unit for bending and twisting tests of ultra-thin films on a flexible substrate
NASA Astrophysics Data System (ADS)
D'souza, Slavia Deeksha; Hazarika, Pratim; Prakasarao, Ch Surya; Kovendhan, M.; Kumar, R. Arockia; Joseph, D. Paul
2018-04-01
An indigenous unit is designed to test the stability of thin films deposited on to a flexible substrate by inducing a required number of bending and twisting under specific conditions. The unit is designed using aluminum and automated by sending pulse width modulated signals to servo motors using ATmega328 microcontroller. We have tested the unit by imparting stress on to a commercial ITO film deposited on a PET substrate. After a definite number of bending and twisting cycles, the electrical and surface properties are studied and the results are discussed.
2010-10-27
The first of nine chemical steam generator (CSG) units that will be used on the A-3 Test Stand is prepared for installation Oct. 24, 2010, at John C. Stennis Space Center. The unit was installed at the E-2 Test Stand for verification and validation testing before it is moved to the A-3 stand. Steam generated by the nine CSG units that will be installed on the A-3 stand will create a vacuum that allows Stennis operators to test next-generation rocket engines at simulated altitudes up to 100,000 feet.
2010-10-22
The first of nine chemical steam generator (CSG) units that will be used on the A-3 Test Stand arrived at John. C. Stennis Space Center on Oct. 22, 2010. The unit was installed at the E-2 Test Stand for verification and validation testing before it is moved to the A-3 stand. Steam generated by the nine CSG units that will be installed on the A-3 stand will create a vacuum that allows Stennis operators to test next-generation rocket engines at simulated altitudes up to 100,000 feet.
Course in Carpentry: Interior Finish. Workbook and Tests.
ERIC Educational Resources Information Center
Strazicich, Mirko, Ed.
Designed for use in carpentry apprenticeship classes, this workbook contains nine units on carpentry skills in the area of interior finish, lists of recommended and required instructional materials, and nine unit tests. Each instructional unit includes a listing of performance statements and text covering skills addressed in individual performance…
49 CFR 234.253 - Flashing light units and lamp voltage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Flashing light units and lamp voltage. 234.253... Maintenance, Inspection, and Testing Inspections and Tests § 234.253 Flashing light units and lamp voltage. (a... proper alignment and frequency of flashes in accordance with installation specifications. (b) Lamp...
49 CFR 234.253 - Flashing light units and lamp voltage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Flashing light units and lamp voltage. 234.253... Maintenance, Inspection, and Testing Inspections and Tests § 234.253 Flashing light units and lamp voltage. (a... proper alignment and frequency of flashes in accordance with installation specifications. (b) Lamp...
NASA Technical Reports Server (NTRS)
Mason, M. G.
1975-01-01
A simulator is described, which was designed for testing and evaluating inertial measuring units, and flight platforms. Mechanical and electrical specifications for the outer, middle, and inner axis are presented. Test results are included.
Stability tests at Browns Ferry Unit 1 under single-loop operating conditions
DOE Office of Scientific and Technical Information (OSTI.GOV)
March-Leuba, J.; Wood, R.T.; Otaduy, P.J.
1986-07-01
The results of neutronic stability tests performed on February 9, 1985, at the Browns Ferry Nuclear Power Plant Unit 1 under single-loop operation (SLO) conditions are documented. The main conclusions of the tests are presented.
Apollo telescope mount thermal systems unit thermal vacuum test
NASA Technical Reports Server (NTRS)
Trucks, H. F.; Hueter, U.; Wise, J. H.; Bachtel, F. D.
1971-01-01
The Apollo Telescope Mount's thermal systems unit was utilized to conduct a full-scale thermal vacuum test to verify the thermal design and the analytical techniques used to develop the thermal mathematical models. Thermal vacuum test philosophy, test objectives configuration, test monitoring, environment simulation, vehicle test performance, and data correlation are discussed. Emphasis is placed on planning and execution of the thermal vacuum test with particular attention on problems encountered in conducting a test of this maguitude.
Agriculture Library of Test Items.
ERIC Educational Resources Information Center
Sutherland, Duncan, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection is reviewed for content validity and reliability. The test…
10 CFR 431.325 - Units to be tested.
Code of Federal Regulations, 2011 CFR
2011-01-01
... EQUIPMENT Metal Halide Lamp Ballasts and Fixtures Test Procedures § 431.325 Units to be tested. For each basic model of metal halide lamp ballast selected for testing, a sample of sufficient size, no less than... energy efficiency calculated as the measured output power to the lamp divided by the measured input power...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-29
.... (Mitsubishi) for a similar line of commercial multi-split air-conditioning systems: Testing laboratories...-conditioning systems: (1) Testing laboratories cannot test products with so many indoor units; (2) there are too many possible combinations of indoor and outdoor unit to test. The Daikin VRV-WIII systems have...
Successful completion of a cyclic ground test of a mercury ion auxiliary propulsion system
NASA Technical Reports Server (NTRS)
Francisco, David R.; Low, Charles A., Jr.; Power, John L.
1988-01-01
An engineering model Ion Auxiliary Propulsion System (IAPS) 8-cm thruster (S/N 905) has completed a life test at NASA Lewis Research Center. The mercury ion thruster successfully completed and exceeded the test goals of 2557 on/off cycles and 7057 hr of operation at full thrust. The final 1200 cycles and 3600 hr of the life test were conducted using an engineering model of the IAPS power electronics unit (PEU) and breadboard digital controller and interface unit (DCIU). This portion of the test is described in this paper with a charted history of thruster operating parameters and off-normal events. Performance and operating characteristics were constant throughout the test with only minor variations. The engineering model power electronics unit operated without malfunction; the flight software in the digital controller and interface unit was exercised and verified. Post-test inspection of the thruster revealed facility enhanced accelerator grid erosion but overall the thruster was in good condition. It was concluded that the thruster performance was not drastically degraded by time or cycles. Additional cyclic testing is currently under consideration.
Successful completion of a cyclic ground test of a mercury Ion Auxiliary Propulsion System
NASA Technical Reports Server (NTRS)
Francisco, David R.; Low, Charles A., Jr.; Power, John L.
1988-01-01
An engineering model Ion Auxiliary Propulsion System (IAPS) 8-cm thruster (S/N 905) has completed a life test at NASA Lewis Research Center. The mercury ion thruster successfully completed and exceeded the test goals of 2557 on/off cycles and 7057 hr of operation at full thrust. The final 1200 cycles and 3600 hr of the life test were conducted using an engineering model of the IAPS power electronics unit (PEU) and breadboard digital controller and interface unit (DCIU). This portion of the test is described in this paper with a charted history of thruster operating parameters and off-normal events. Performance and operating characteristics were constant throughout the test with only minor variations. The engineering model power electronics unit operated without malfunction; the flight software in the digital controller and interface unit was exercised and verified. Post-test inspection of the thruster revealed facility enhanced accelerator grid erosion but overall the thruster was in good condition. It was concluded that the thruster performance was not drastically degraded by time or cycles. Additional cyclic testing is currently under consideration.
Martin, Edward J [Virginia Beach, VA
2008-01-15
A voltage verification unit and method for determining the absence of potentially dangerous potentials within a power supply enclosure without Mode 2 work is disclosed. With this device and method, a qualified worker, following a relatively simple protocol that involves a function test (hot, cold, hot) of the voltage verification unit before Lock Out/Tag Out and, and once the Lock Out/Tag Out is completed, testing or "trying" by simply reading a display on the voltage verification unit can be accomplished without exposure of the operator to the interior of the voltage supply enclosure. According to a preferred embodiment, the voltage verification unit includes test leads to allow diagnostics with other meters, without the necessity of accessing potentially dangerous bus bars or the like.
Dynamic of small photovoltaic systems
NASA Astrophysics Data System (ADS)
Mehrmann, A.; Kleinkauf, W.; Pigorsch, W.; Steeb, H.
The results of 1.5 yr of field-testing of two photovoltaic (PV) power plants, one equipped with an electrolyzer and H2 storage, are reported. Both systems were interconnected with the grid and featured the PV module, a power conditioning unit, ac and dc load connections, and control units. The rated power of both units was 100 Wp. The system with electrolysis was governed by control laws which maximized the electrolyzer current. The tests underscored the preference for a power conditioning unit, rather than direct output to load connections. A 1 kWp system was developed in a follow-up program and will be tested in concert with electrolysis and interconnection with several grid customers. The program is geared to eventual development of larger units for utility-size applications.
XM587E2/XM724 Electronic Time Fuzes: Developmental Test/Operational Test (DT/OT) II Test Phase
1979-11-01
unit - da.- aged setbac* spring Sunit - damAged setback pia 140 .4 C) Twenty-five units were subjected to variable testing "to determine tho G level...SAXIP ACCEPT REJECT NO. Ttf7l KSCRIFTI( AG sin4 go flj-. cEI~ *S-FOOTMOP TEsT o 0 (DROPPED IN FIVE DIFFRNT csIllvrATIaNS -- 1 PER OCRIMP... ascue bya i i*ctet FAILURE AND ACTION REPORT 71134 Jj 7113 .I ,...,-... 7 wow o ft.-I I The unIt will not tht. bte the the scalet inpf t to the.uner h
González, Rocio; Echevarria, José Manuel; Avellón, Ana; Barea, Luisa; Castro, Emma
2006-07-01
Mathematical models predict that, in Spain, a significant number of blood units will be obtained during the window period of the hepatitis B virus (HBV) infection. Routine nucleic acid testing (NAT) on individual blood units may provide experimental data to evaluate such a theoretical risk. Between February and July 2005, a total of 34,631 individual units were screened for HBV DNA by a multiplex transcription-mediated amplification (TMA) test. Units that repeatedly reacted in the test, but did not react for HBV surface antigen (HBsAg), were submitted to additional testing by both molecular and conventional assays, and the donors were recalled for follow-up studies and the collection of clinical and epidemiologic data. Confirmatory testing and follow-up studies identified 2 blood units donated during the HBV infection window period (1/17,316 units studied). Sequencing of amplification products obtained by nested polymerase chain reaction (n-PCR) revealed two HBV strains from genotypes D/ayw3 and F/adw4q-, but did not identify HBsAg mutants. The HBV DNA concentration in the index donations was estimated to be below the n-PCR detection level (180 IU/mL), in both cases. One donor developed acute hepatitis 2 months after donating blood, but the other remained asymptomatic and displayed normal alanine aminotransferase levels at follow-up. The HBV infection window period is a real issue in the setting of Spanish blood transfusions. NAT of individual units by TMA would make a significant contribution to improving the safety of the blood supply in Spain. Additional studies involving a larger number of units and longer periods of time are required, however, to ascertain the true incidence of the problem in this country.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bickes, R.W. Jr.; Wackerbarth, D.E.; Mohler, J.H.
1996-12-31
The authors report on recent studies comparing the ignition threshold of temperature cycled, SCB thermite devices with units that were not submitted to temperature cycling. Aluminum/copper-oxide thermite was pressed into units at two densities, 45% of theoretical maximum density (TMD) or 47% of TMD. Half of each of the density sets underwent three thermal cycles; each cycle consisted of 2 hours at 74 C and 2 hours at {minus}54 C, with a 5 minute maximum transfer time between temperatures. The temperature cycled units were brought to ambient temperature before the threshold testing. Both the density and the thermal cycling affectedmore » the all-fire voltage. Using a 5.34 {micro}F CDU (capacitor discharge unit) firing set, the all-fire voltage for the units that were not temperature cycled increased with density from 32.99 V (45% TMD) to 39.32 V (47% TMD). The all-fire voltages for the thermally cycled units were 34.42 V (45% TMD) and 58.1 V (47% TMD). They also report on no-fire levels at ambient temperature for two component designs; the 5 minute no-fire levels were greater than 1.2 A. Units were also subjected to tests in which 1 W of RF power was injected into the bridges at 10 MHz for 5 minutes. The units survived and fired normally afterwards. Finally, units were subjected to pin-to-pin electrostatic discharge (ESD) tests. None of the units fired upon application of the ESD pulse, and all of the tested units fired normally afterwards.« less
Bottom-up or top-down: unit cost estimation of tuberculosis diagnostic tests in India.
Rupert, S; Vassall, A; Raizada, N; Khaparde, S D; Boehme, C; Salhotra, V S; Sachdeva, K S; Nair, S A; Hoog, A H Van't
2017-04-01
Of 18 sites that participated in an implementation study of the Xpert® MTB/RIF assay in India, we selected five microscopy centres and two reference laboratories. To obtain unit costs of diagnostic tests for tuberculosis (TB) and drug-resistant TB. Laboratories were purposely selected to capture regional variations and different laboratory types. Both bottom-up and the top-down methods were used to estimate unit costs. At the microscopy centres, mean bottom-up unit costs were respectively US$0.83 (range US$0.60-US$1.10) and US$12.29 (US$11.61-US$12.89) for sputum smear microscopy and Xpert. At the reference laboratories, mean unit costs were US$1.69 for the decontamination procedure, US$9.83 for a solid culture, US$11.06 for a liquid culture, US$29.88 for a drug susceptibility test, and US$18.18 for a line-probe assay. Top-down mean unit cost estimates were higher for all tests, and for sputum smear microscopy and Xpert these increased to respectively US$1.51 and US$13.58. The difference between bottom-up and top-down estimates was greatest for tests performed at the reference laboratories. These unit costs for TB diagnostics can be used to estimate resource requirements and cost-effectiveness in India, taking into account geographical location, laboratory type and capacity utilisation.
Cox, Louis Anthony; Popken, Douglas A; VanSickle, John J; Sahu, Ranajit
2005-08-01
The U.S. Department of Agriculture (USDA) tests a subset of cattle slaughtered in the United States for bovine spongiform encephalitis (BSE). Knowing the origin of cattle (U.S. vs. Canadian) at testing could enable new testing or surveillance policies based on the origin of cattle testing positive. For example, if a Canadian cow tests positive for BSE, while no U.S. origin cattle do, the United States could subject Canadian cattle to more stringent testing. This article illustrates the application of a value-of-information (VOI) framework to quantify and compare potential economic costs to the United States of implementing tracking cattle origins to the costs of not doing so. The potential economic value of information from a tracking program is estimated to exceed its costs by more than five-fold if such information can reduce future losses in export and domestic markets and reduce future testing costs required to reassure or win back customers. Sensitivity analyses indicate that this conclusion is somewhat robust to many technical, scientific, and market uncertainties, including the current prevalence of BSE in the United States and/or Canada and the likely reactions of consumers to possible future discoveries of BSE in the United States and/or Canada. Indeed, the potential value of tracking information is great enough to justify locating and tracking Canadian cattle already in the United States when this can be done for a reasonable cost. If aggressive tracking and testing can win back lost exports, then the VOI of a tracking program may increase to over half a billion dollars per year.
Water Ingestion into Axial Flow Compressors. Part III. Experimental Results and Discussion
1981-10-01
total pressure, static pressure, and temperature at both compressor inlet and outlet. A United Sensor model PDC-12-G-l0-KL pitot-static pressure probe...Test Compressor inlet and outlet temperatures during water injection tests: United Sensor and Control Corp. type TK-8-CiA-36’-F Aspirate...ured utilizing standard aspirated thermocouples, namely an United Sensor and Control Corp. type TK-8-C/A-36-F. The Test Compressor out- let
Water absorption characteristic of interlocking compressed earth brick units
NASA Astrophysics Data System (ADS)
Bakar, B. H. Abu; Saari, S.; Surip, N. A.
2017-10-01
This study aims to investigate the water absorption characteristic of interlocking compressed earth brick (ICEB) units. Apart from compressive strength, water absorption is an important property in masonry. This property can affect the quality of the brick itself and the bond strength between the brick and mortar in masonry structures and can result in reducing its strength properties. The units were tested for 24 h water absorption and 5 h boiling water absorption. A total of 170 ICEB units from four ICEB types underwent both tests. For the 24 h water absorption, the ICEB units were dried in the oven for 24 h and then cooled before being weighed. Thereafter, each brick was immersed in water for 24 h and weighed. The same specimens used for the 24 h water absorption test were re-used for the 5 h boiling water absorption test. After completing the 24 h water absorption test, the brick was boiled for 5-hours and weighed. The highest water absorption for the ICEBs in the 24-hour water absorption and 5 h boiling water absorption tests are 15.09% and 17.18%, respectively. The half brick has the highest water absorption (15.87%), whereas the beam brick has the lowest (13.20%). The water absorption of an ICEB unit is higher than that of normal bricks, although the water absorption of the former remains below the maximum rate of the brick water absorption (21%).
Sá, Luísa; Teixeira, Andreia Sofia Costa; Tavares, Fernando; Costa-Santos, Cristina; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto Pinto; Santos, Paulo
2017-01-01
Objectives To characterise the test ordering pattern in Northern Portugal and to investigate the influence of context-related factors, analysing the test ordered at the level of geographical groups of family physicians and at the level of different healthcare organisations. Design Cross-sectional study. Setting Northern Primary Health Care, Portugal. Participants Records about diagnostic and laboratory tests ordered from 2035 family physicians working at the Northern Regional Health Administration, who served approximately 3.5 million Portuguese patients, in 2014. Outcomes To determine the 20 most ordered diagnostic and laboratory tests in the Northern Regional Health Administration; to identify the presence and extent of variations in the 20 most ordered diagnostic and laboratory tests between the Groups of Primary Care Centres and between health units; and to study factors that may explain these variations. Results The 20 most ordered diagnostic and laboratory tests almost entirely comprise laboratory tests and account for 70.9% of the total tests requested. We can trace a major pattern of test ordering for haemogram, glucose, lipid profile, creatinine and urinalysis. There was a significant difference (P<0.001) in test orders for all tests between Groups of Primary Care Centres and for all tests, except glycated haemoglobin (P=0.06), between health units. Generally, the Personalised Healthcare Units ordered more than Family Health Units. Conclusions The results from this study show that the most commonly ordered tests in Portugal are laboratory tests, that there is a tendency for overtesting and that there is a large variability in diagnostic and laboratory test ordering in different geographical and organisational Portuguese primary care practices, suggesting that there may be considerable potential for the rationalisation of test ordering. The existence of Family Health Units seems to be a strong determinant in decreasing test ordering by Portuguese family physicians. Approaches to ensuring more rational testing are needed. PMID:29146654
Distribution of indoor radon concentrations in Pennsylvania, 1990-2007
Gross, Eliza L.
2013-01-01
Median indoor radon concentrations aggregated according to geologic units and hydrogeologic settings are useful for drawing general conclusions about the occurrence of indoor radon in specific geologic units and hydrogeologic settings, but the associated data and maps have limitations. The aggregated indoor radon data have testing and spatial accuracy limitations due to lack of available information regarding testing conditions and the imprecision of geocoded test locations. In addition, the associated data describing geologic units and hydrogeologic settings have spatial and interpretation accuracy limitations, which are a result of using statewide data to define conditions at test locations and geologic data that represent a broad interpretation of geologic units across the State. As a result, indoor air radon concentration distributions are not proposed for use in predicting individual concentrations at specific sites nor for use as a decision-making tool for property owners to decide whether to test for indoor radon concentrations at specific property locations.
Plated wire random access memories
NASA Technical Reports Server (NTRS)
Gouldin, L. D.
1975-01-01
A program was conducted to construct 4096-work by 18-bit random access, NDRO-plated wire memory units. The memory units were subjected to comprehensive functional and environmental tests at the end-item level to verify comformance with the specified requirements. A technical description of the unit is given, along with acceptance test data sheets.
A PLAN FOR FIELD TESTING R/I UNITS.
ERIC Educational Resources Information Center
WARDROP, JAMES L.; AND OTHERS
THIS PAPER DISCUSSES THE FIELD TESTING OF RESEARCH AND INSTRUCTION UNITS IN OPERATION IN A NUMBER OF WISCONSIN SCHOOLS. THE UNIT IS A REORGANIZED SCHOOL STRUCTURE WHICH IS MADE UP OF A LEARNING SPECIALIST LEADER, TEACHERS, PARAPROFESSIONALS, AND STUDENTS. THE MAJOR AIMS OF THIS EDUCATIONAL INNOVATION ARE (1) TO DEVELOP AND MAINTAIN AN…
Introduction to Production/Manufacturing Drafting. Drafting Module 8. Instructor's Guide.
ERIC Educational Resources Information Center
Missouri Univ., Columbia. Instructional Materials Lab.
This module, 1 of 10 in the Drafting curriculum guide developed in Missouri, contains 3 units of study that include some or all of the following components: performance objectives, lesson plans, information sheets, transparency masters, handouts, assignment sheets, job sheets, a unit test, and answers to the unit test. Special instructions on…
Major Appliance Repair. Teacher Edition and Student Edition. Second Edition.
ERIC Educational Resources Information Center
Smreker, Gene; Calvert, King
This second edition contains teacher and student guides for 14 units of instruction in major appliance repair. Each unit in the teacher edition includes some or all of the following basic components: objective sheet, suggested activities, answers to assignment sheets, answers to the written test, written test, a unit evaluation form, teacher…
ERIC Educational Resources Information Center
New South Wales Dept. of Education, Sydney (Australia).
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…
ERIC Educational Resources Information Center
New South Wales Dept. of Education, Sydney (Australia).
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…
ERIC Educational Resources Information Center
New South Wales Dept. of Education, Sydney (Australia).
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…
Eddy-Current Detection of Weak Bolt Heads
NASA Technical Reports Server (NTRS)
Messina, C. P.
1987-01-01
Electronic test identifies flawed units passing hardness tests. Eddy-current test detects weakness in head-to-shank junctions of 1/4-28 cup-washer lock bolts. Developed for alloy A286 steel bolts in Space Shuttle main engine fuel turbo-pump. Test examines full volume of head, including head-to-shank transition and nondestructively screens out potentially defective units. Test adapts to any other alloys.
Testing for purchasing power parity in 21 African countries using several unit root tests
NASA Astrophysics Data System (ADS)
Choji, Niri Martha; Sek, Siok Kun
2017-04-01
Purchasing power parity is used as a basis for international income and expenditure comparison through the exchange rate theory. However, empirical studies show disagreement on the validity of PPP. In this paper, we conduct the testing on the validity of PPP using panel data approach. We apply seven different panel unit root tests to test the validity of the purchasing power parity (PPP) hypothesis based on the quarterly data on real effective exchange rate for 21 African countries from the period 1971: Q1-2012: Q4. All the results of the seven tests rejected the hypothesis of stationarity meaning that absolute PPP does not hold in those African Countries. This result confirmed the claim from previous studies that standard panel unit tests fail to support the PPP hypothesis.
Thermal vacuum life test facility for radioisotope thermoelectric generators
NASA Astrophysics Data System (ADS)
Deaton, R. L.; Goebel, C. J.; Amos, W. R.
In the late 1970's, the Department of Energy (DOE) assigned Monsanto Research Corporation, Mound Facility, now operated by EG and G Mound Applied Technologies, the responsibility for assembling and testing General Purpose Heat Source (GPHS) radioisotope thermoelectric generators (RTGs). Assembled and tested were five RTGs, which included four flight units and one non-flight qualification unit. Figure 1 shows the RTG, which was designed by General Electric AstroSpace Division (GE/ASD) to produce 285 W of electrical power. A detailed description of the processes for RTG assembly and testing is presented by Amos and Goebel (1989). The RTG performance data are described by Bennett, et al., (1986). The flight units will provide electrical power for the National Aeronautics and Space Administration's (NASA) Galileo mission to Jupiter (two RTGs) and the joint NASA/European Space Agency (ESA) Ulysses mission to study the polar regions of the sun (one RTG). The remaining flight unit will serve as the spare for both missions, and a non-flight qualification unit was assembled and tested to ensure that performance criteria were adequately met.
Multichannel electrochemical microbial detection unit
NASA Technical Reports Server (NTRS)
Wilkins, J. R.; Young, R. N.; Boykin, E. H.
1978-01-01
The paper describes the design and capabilities of a compact multichannel electrochemical unit devised to detect and automatically indicate detection time length of bacteria. By connecting this unit to a strip-chart recorder, a permanent record is obtained of the end points and growth curves for each of eight channels. The experimental setup utilizing the multichannel unit consists of a test tube (25 by 150 mm) containing a combination redox electrode plus 18 ml of lauryl tryptose broth and positioned in a 35-C water bath. Leads from the electrodes are connected to the multichannel unit, which in turn is connected to a strip-chart recorder. After addition of 2.0 ml of inoculum to the test tubes, depression of the push-button starter activates the electronics, timer, and indicator light for each channel. The multichannel unit is employed to test tenfold dilutions of various members of the Enterobacteriaceae group, and a typical dose-response curve is presented.
NASA Astrophysics Data System (ADS)
Pang, Zuobo; Zhou, Hong; Xie, Guofeng; Cong, Dalong; Meng, Chao; Ren, Luquan
2015-07-01
In order to get close to the wear form of guide rails, the homemade linear reciprocating wear testing machine was used for the wear test. In order to improve the wear-resistance of gray cast iron guide rail, bionic coupling units of different forms were manufactured by a laser. Wear behavior of gray-cast-iron with bionic-coupling units has been studied under dry sliding condition at room temperature using the wear testing machine. The wear resistance was evaluated by means of weight loss measurement and wear morphology. The results indicated that bionic coupling unit could improve the wear resistance of gray cast iron. The wear resistance of gray cast iron with reticulation bionic coupling unit is the best. When the load and speed changed, reticulation bionic coupling unit still has excellent performance in improving the wear resistance of gray cast iron.
29 CFR Appendix E to Subpart L of... - Test Methods for Protective Clothing
Code of Federal Regulations, 2012 CFR
2012-07-01
... strength of the specimen shall be the average of the five highest peak loads of resistance registered for 3... convenience. (2) Test method for determining the strength of cloth by tearing: Trapezoid Method. A. Test... directions shall be tested from each sample unit. (ii) The tearing strength of the sample unit shall be the...
29 CFR Appendix E to Subpart L of... - Test Methods for Protective Clothing
Code of Federal Regulations, 2014 CFR
2014-07-01
... strength of the specimen shall be the average of the five highest peak loads of resistance registered for 3... convenience. (2) Test method for determining the strength of cloth by tearing: Trapezoid Method. A. Test... directions shall be tested from each sample unit. (ii) The tearing strength of the sample unit shall be the...
Geography Library of Test Items. Volume Four.
ERIC Educational Resources Information Center
Kouimanos, John, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Home Science Library of Test Items. Volume One.
ERIC Educational Resources Information Center
Smith, Jan, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection is reviewed for content validity and reliability. The test…
Languages Library of Test Items. Volume Two: German, Latin.
ERIC Educational Resources Information Center
Campbell, Thomas; And Others
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Languages Library of Test Items. Volume One: French, Indonesian.
ERIC Educational Resources Information Center
Campbell, Thomas; And Others
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Geography Library of Test Items. Volume Three.
ERIC Educational Resources Information Center
Kouimanos, John, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Commerce Library of Test Items. Volume One.
ERIC Educational Resources Information Center
Meeve, Brian, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Geography Library of Test Items. Volume Five.
ERIC Educational Resources Information Center
Kouimanos, John, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Textiles and Design Library of Test Items. Volume I.
ERIC Educational Resources Information Center
Smith, Jan, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection is reviewed for content validity and reliability. The test…
Commerce Library of Test Items. Volume Two.
ERIC Educational Resources Information Center
Meeve, Brian, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Geography Library of Test Items. Volume Six.
ERIC Educational Resources Information Center
Kouimanos, John, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Geography: Library of Test Items. Volume II.
ERIC Educational Resources Information Center
Kouimanos, John, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Accounting Clerk Guide, Test Packet--Part I.
ERIC Educational Resources Information Center
Foster, Brian; And Others
The test packet is part of an eight volume unit for grades 10, 11, and 12, designed for individualized progression in preparing students for entry into the occupation of accounting clerk. The test packet contains both pretests and post-tests for lessons 1 through 12. The unit is concerned with the basic accounting theory found in the accounting…
United States History. Annotated Bibliography of Tests.
ERIC Educational Resources Information Center
Educational Testing Service, Princeton, NJ. Test Collection.
The 33 tests in this bibliography cover United States History from the period of exploration of the continent through the Civil War to Post World War II. One test measures knowledge of African American history. Types of measures include credit by examination, item banks, and end-of-course tests. All ages are represented but the majority of tests…
NASA Technical Reports Server (NTRS)
Heffner, R. J.
1998-01-01
This is the Engineering Test Report, AMSU-AL METSAT Instrument (S/N 105) Qualification Level Vibration Tests of December 1998 (S/0 605445, OC-419), for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).
NASA Technical Reports Server (NTRS)
Valdez, A.
2000-01-01
This is the Engineering Test Report, Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A1, S/N 109, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).
Geography Library of Test Items. Volume One.
ERIC Educational Resources Information Center
Kouimanos, John, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
NASA Technical Reports Server (NTRS)
Lebron, Ramon C.; Oliver, Angela C.; Bodi, Robert F.
1991-01-01
Power components hardware in support of the Space Station Freedom dc Electrical Power System were tested. One type of breadboard hardware tested is the dc Load Converter Unit, which constitutes the power interface between the electric power system and the actual load. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. Three load converters were tested: a series resonant converter, a series inductor switchmode converter, and a switching full-bridge forward converter. The topology, operation principles, and tests results are described, in general. A comparative analysis of the three units is given with respect to efficiency, regulation, short circuit behavior (protection), and transient characteristics.
LONG-TERM DEMONSTRATION OF SORBENT ENHANCEMENT ADDITIVE TECHNOLOGY FOR MERCURY CONTROL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jason D. Laumb; Dennis L. Laudal; Grant E. Dunham
2011-05-27
Long-term demonstration tests of advanced sorbent enhancement additive (SEA) technologies have been completed at five coal-fired power plants. The targeted removal rate was 90% from baseline conditions at all five stations. The plants included Hawthorn Unit 5, Mill Creek Unit 4, San Miguel Unit 1, Centralia Unit 2, and Hoot Lake Unit 2. The materials tested included powdered activated carbon, treated carbon, scrubber additives, and SEAs. In only one case (San Miguel) was >90% removal not attainable. The reemission of mercury from the scrubber at this facility prevented >90% capture.
Flight prototype regenerative particulate filter system development
NASA Technical Reports Server (NTRS)
Green, D. C.; Garber, P. J.
1974-01-01
The effort to design, fabricate, and test a flight prototype Filter Regeneration Unit used to regenerate (clean) fluid particulate filter elements is reported. The design of the filter regeneration unit and the results of tests performed in both one-gravity and zero-gravity are discussed. The filter regeneration unit uses a backflush/jet impingement method of regenerating fluid filter elements that is highly efficient. A vortex particle separator and particle trap were designed for zero-gravity use, and the zero-gravity test results are discussed. The filter regeneration unit was designed for both inflight maintenance and ground refurbishment use on space shuttle and future space missions.
NASA Astrophysics Data System (ADS)
Kaszeta, W. J.
1982-12-01
One of the primary obstacles to the application of vaccination in developing countries is the lack of refrigerated storage. Vaccines exposed to elevated temperatures suffer a permanent loss of potency. Photovoltaic (PV) powered refrigerator/freezer (R/F) units could surmount the problem of refrigeration in remote areas where no reliable commercial power supply is available. The performance measurements of two different models of PV powered R/F units for medical use are presented. Qualification testing consisted of four major procedures: no-load pull down, ice making, steady-state (maintenance), and holdover. Both R/F units met the major World Health Organization (WHO) requirements. However, the testing performed does not provide complete characterization of the two units; such information could be derived only from further extensive test procedures.
NASA Technical Reports Server (NTRS)
Kaszeta, W. J.
1982-01-01
One of the primary obstacles to the application of vaccination in developing countries is the lack of refrigerated storage. Vaccines exposed to elevated temperatures suffer a permanent loss of potency. Photovoltaic (PV) powered refrigerator/freezer (R/F) units could surmount the problem of refrigeration in remote areas where no reliable commercial power supply is available. The performance measurements of two different models of PV powered R/F units for medical use are presented. Qualification testing consisted of four major procedures: no-load pull down, ice making, steady-state (maintenance), and holdover. Both R/F units met the major World Health Organization (WHO) requirements. However, the testing performed does not provide complete characterization of the two units; such information could be derived only from further extensive test procedures.
Design, construction, and testing of a five active axes magnetic bearing system
NASA Technical Reports Server (NTRS)
Delprete, Cristiana; Genta, Giancarlo; Carabelli, Stefano
1994-01-01
A high speed electric spindle based on active electromagnetic suspension technology has been designed, built, and tested. The main goal of the research work was the construction of a highly modular unit which can be used for teaching and research purposes. The design of the electromechanical components and of the control unit is described in detail, together with the characterization tests performed on the various subsystems. A description of the preliminary tests on the unit, conducted at speeds not in excess of the first deformation critical speed of the rotor, concludes the work.
2010-10-27
The first of nine chemical steam generator (CSG) units that will be used on the A-3 Test Stand is hoisted into place at the E-2 Test Stand at John C. Stennis Space Center on Oct. 24, 2010. The unit was installed at the E-2 stand for verification and validation testing before it is moved to the A-3 stand. Steam generated by the nine CSG units that will be installed on the A-3 stand will create a vacuum that allows Stennis operators to test next-generation rocket engines at simulated altitudes up to 100,000 feet.
Multiple Hollow Cathode Wear Testing for the Space Station Plasma Contactor
NASA Technical Reports Server (NTRS)
Soulas, George C.
1994-01-01
A wear test of four hollow cathodes was conducted to resolve issues associated with the Space Station plasma contactor. The objectives of this test were to evaluate unit-to-unit dispersions, verify the transportability of contamination control protocols developed by the project, and to evaluate cathode contamination control and activation procedures to enable simplification of the gas feed system and heater power processor. These objectives were achieved by wear testing four cathodes concurrently to 2000 hours. Test results showed maximum unit-to-unit deviations for discharge voltages and cathode tip temperatures to be +/-3 percent and +/-2 percent, respectively, of the nominal values. Cathodes utilizing contamination control procedures known to increase cathode lifetime showed no trends in their monitored parameters that would indicate a possible failure, demonstrating that contamination control procedures had been successfully transferred. Comparisons of cathodes utilizing and not utilizing a purifier or simplified activation procedure showed similar behavior during wear testing and pre- and post-test performance characterizations. This behavior indicates that use of simplified cathode systems and procedures is consistent with long cathode lifetimes.
Ground test challenges in the development of the Space Shuttle orbiter auxiliary power unit
NASA Technical Reports Server (NTRS)
Chaffee, N. H.; Lance, R. J.; Weary, D. P.
1984-01-01
A conventional aircraft hydraulic system design approach was selected to provide fluid power for the Space Shuttle Orbiter. Developing the power unit, known as the Auxiliary Power Unit (APU), to drive the hydraulic pumps presented a major technological challenge. A small, high speed turbine drive unit powered by catalytically decomposed hydrazine and operating in the pulse mode was selected to meet the requirement. Because of limitations of vendor test facilities, significant portions of the development, flight qualification, and postflight anomaly testing of the Orbiter APU were accomplished at the Johnson Space Center (JSC) test facilities. This paper discusses the unique requirements of attitude, gravity forces, pressure profiles, and thermal environments which had to be satisfied by the APU, and presents the unique test facility and simulation techniques employed to meet the ground test requirements. In particular, the development of the zero-g lubrication system, the development of necessary APU thermal control techniques, the accomplishment of integrated systems tests, and the postflight investigation of the APU lube oil cooler behavior are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, J.E.; Whisnant, R.B.
The report provides an in-depth evaluation of an ultraviolet (UV) disinfection unit as applied to the treatment of cooling water in a textile air washer system. The UV unit tests used a teflon tube to transport the aquatic phase. The unit reduced microbial populations and maintained an average level of 10,000 Colony formed unites/mL for the 6-month testing period, without the addition of biocides. No cleaning or other maintenance was required of the wetted surfaces during the testing period. Slime deposits observed on walls of the air washer during chemical treatment were also eliminated. The UV unit can be utilizedmore » on both cooling towers and air washers without extensive installation.« less
Heat Pump Water Heater Durabliltiy Testing - Phase II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baxter, VAND.
2004-05-29
Ten heat pump water heaters (HPWH) were placed in an environmentally controlled test facility and run through a durability test program of approximately 7300 duty cycles (actual cycles accumulated ranged from 6640 to 8324 for the ten units). Five of the units were upgraded integral types (HPWH mounted on storage tank, no pump) from the same manufacturer as those tested in our first durability program in 2001 (Baxter and Linkous, 2002). The other five were ''add-on'' type units (HPWH with circulation pump plumbed to a separate storage tank) from another manufacturer. This durability test was designed to represent approximately 7-10more » years of normal operation to meet the hot water needs of a residence. The integral units operated without incident apart from two control board failures. Both of these were caused by inadvertent exposure to very hot and humid (>135 F dry bulb and >120 F dew point) conditions that occurred due to a test loop failure. It is not likely that any residential water heater would be installed where such conditions were expected so these failures are not considered a long-term reliability concern. Two of the integral HPWHs featured a condensate management system (CMS) option that effectively eliminated any need for an evaporator condensate drain, but imposed significant efficiency penalties when operating in high humidity ambient conditions. The add-on units experienced no operational failures (breakdowns with loss of hot water production) during the course of the testing. However, their control systems exhibited some performance degradation under the high temperature, high humidity test conditions--HPWHs would shut off with tank water temperatures 15-20 F lower than when operating under moderate ambient conditions. One unit developed a refrigerant leak during the test program and lost about 50% of its charge resulting in reduced efficiency. Efficiency measurements on all the integral units and four of the add-on units showed significantly higher efficiencies than conventional electric water heaters (EWH). DOE Simulated Use Tests conducted prior to starting the durability testing resulted in energy factors (EF) of about 2.3 for the integral design and 1.4 for the add-on design compared to the minimum value of 0.86 prescribed for EWHs. Based on the experience from this and the previous durability testing, there is no evidence that strongly suggests that any of the HPWHs suffered significant performance degradation after undergoing over 7000 water heat cycles.« less
Economic and workflow analysis of a blood bank automated system.
Shin, Kyung-Hwa; Kim, Hyung Hoi; Chang, Chulhun L; Lee, Eun Yup
2013-07-01
This study compared the estimated costs and times required for ABO/Rh(D) typing and unexpected antibody screening using an automated system and manual methods. The total cost included direct and labor costs. Labor costs were calculated on the basis of the average operator salaries and unit values (minutes), which was the hands-on time required to test one sample. To estimate unit values, workflows were recorded on video, and the time required for each process was analyzed separately. The unit values of ABO/Rh(D) typing using the manual method were 5.65 and 8.1 min during regular and unsocial working hours, respectively. The unit value was less than 3.5 min when several samples were tested simultaneously. The unit value for unexpected antibody screening was 2.6 min. The unit values using the automated method for ABO/Rh(D) typing, unexpected antibody screening, and both simultaneously were all 1.5 min. The total cost of ABO/Rh(D) typing of only one sample using the automated analyzer was lower than that of testing only one sample using the manual technique but higher than that of testing several samples simultaneously. The total cost of unexpected antibody screening using an automated analyzer was less than that using the manual method. ABO/Rh(D) typing using an automated analyzer incurs a lower unit value and cost than that using the manual technique when only one sample is tested at a time. Unexpected antibody screening using an automated analyzer always incurs a lower unit value and cost than that using the manual technique.
Engineering Test and Evaluation During High G. Volume III, Anti-G Suits.
1978-06-01
items are: 3 inservice units from USAF and IJSN; an RAF unit; and 2 experimental units (lower body full pressure, and capstan). The study of the capstan...inspections are performed by life-support techni- cians whose training and expertise best enable them to evaluate the anti-G suit condition. The TEHG...of testing in one minute." At some installations this test has been waived by USAF Air Training Command (ATC) to "l psig drop from 5 psig in 20 sec
Lithium-Ion Cell Charge-Control Unit Developed
NASA Technical Reports Server (NTRS)
Reid, Concha M.; Manzo, Michelle A.; Buton, Robert M.; Gemeiner, Russel
2005-01-01
A lithium-ion (Li-ion) cell charge-control unit was developed as part of a Li-ion cell verification program. This unit manages the complex charging scheme that is required when Li-ion cells are charged in series. It enables researchers to test cells together as a pack, while allowing each cell to charge individually. This allows the inherent cell-to-cell variations to be addressed on a series string of cells and reduces test costs substantially in comparison to individual cell testing.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-03
...The U.S. Nuclear Regulatory Commission (NRC or the Commission) is issuing a revision to Regulatory Guide (RG) 1.52, ``Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Post-accident Engineered-Safety-Feature Atmosphere Cleanup Systems in Light-Water-Cooled Nuclear Power Plants.'' This guide applies to the design, inspection, and testing of air filtration and iodine adsorption units of engineered-safety-feature (ESF) atmosphere cleanup systems in light-water-cooled nuclear power plants.
ERIC Educational Resources Information Center
New South Wales Dept. of Education, Sydney (Australia).
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…
ERIC Educational Resources Information Center
Lindley, Patricia A.; Bartram, Dave
2012-01-01
In this article, we present the background to the development of test reviewing by the British Psychological Society (BPS) in the United Kingdom. We also describe the role played by the BPS in the development of the EFPA test review model and its adaptation for use in test reviewing in the United Kingdom. We conclude with a discussion of lessons…
ERIC Educational Resources Information Center
New South Wales Dept. of Education, Sydney (Australia).
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…
ERIC Educational Resources Information Center
New South Wales Dept. of Education, Sydney (Australia).
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…
Nursing workload in public and private intensive care units
Nogueira, Lilia de Souza; Koike, Karina Mitie; Sardinha, Débora Souza; Padilha, Katia Grillo; de Sousa, Regina Marcia Cardoso
2013-01-01
Objective This study sought to compare patients at public and private intensive care units according to the nursing workload and interventions provided. Methods This retrospective, comparative cohort study included 600 patients admitted to 4 intensive care units in São Paulo. The nursing workload and interventions were assessed using the Nursing Activities Score during the first and last 24 hours of the patient's stay at the intensive care unit. Pearson's chi-square test, Fisher's exact test, the Mann-Whitney test, and Student's t test were used to compare the patient groups. Results The average Nursing Activities Score upon admission to the intensive care unit was 61.9, with a score of 52.8 upon discharge. Significant differences were found among the patients at public and private intensive care units relative to the average Nursing Activities Score upon admission, as well as for 12 out of 23 nursing interventions performed during the first 24 hours of stay at the intensive care units. The patients at the public intensive care units exhibited a higher average score and overall more frequent nursing interventions, with the exception of those involved in the "care of drains", "mobilization and positioning", and "intravenous hyperalimentation". The groups also differed with regard to the evolution of the Nursing Activities Score among the total case series as well as the groups of survivors from the time of admission to discharge from the intensive care unit. Conclusion Patients admitted to public and private intensive care units exhibit differences in their nursing care demands, which may help managers with nursing manpower planning. PMID:24213086
30 CFR 74.14 - Certificate of approval.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... (a) Upon completion of the testing of a CMDPSU or the pump unit or after review of testing protocols... unless MSHA has first issued a certificate of approval for either the pump unit of a CMDPSU or for the... the CMDPSU and the pump unit, or of the CPDM, as appropriate, upon which the certificate of approval...
30 CFR 74.14 - Certificate of approval.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... (a) Upon completion of the testing of a CMDPSU or the pump unit or after review of testing protocols... unless MSHA has first issued a certificate of approval for either the pump unit of a CMDPSU or for the... the CMDPSU and the pump unit, or of the CPDM, as appropriate, upon which the certificate of approval...
30 CFR 74.14 - Certificate of approval.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (a) Upon completion of the testing of a CMDPSU or the pump unit or after review of testing protocols... unless MSHA has first issued a certificate of approval for either the pump unit of a CMDPSU or for the... the CMDPSU and the pump unit, or of the CPDM, as appropriate, upon which the certificate of approval...
30 CFR 74.14 - Certificate of approval.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... (a) Upon completion of the testing of a CMDPSU or the pump unit or after review of testing protocols... unless MSHA has first issued a certificate of approval for either the pump unit of a CMDPSU or for the... the CMDPSU and the pump unit, or of the CPDM, as appropriate, upon which the certificate of approval...
30 CFR 74.14 - Certificate of approval.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... (a) Upon completion of the testing of a CMDPSU or the pump unit or after review of testing protocols... unless MSHA has first issued a certificate of approval for either the pump unit of a CMDPSU or for the... the CMDPSU and the pump unit, or of the CPDM, as appropriate, upon which the certificate of approval...
29 CFR 1919.28 - Unit proof tests-cranes and gear accessory thereto.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 7 2011-07-01 2011-07-01 false Unit proof tests-cranes and gear accessory thereto. 1919.28... Loads; Heat Treatment; Competent Persons § 1919.28 Unit proof tests—cranes and gear accessory thereto. (a) Except as noted in paragraph (e) of this section, cranes and other hoisting machines, together...
[Arizona] Field Test Report. Vol. 10. Learn to Earn. 1974-75.
ERIC Educational Resources Information Center
Small, Charles; And Others
The field test report on the "Learn to Earn" instructional unit for grade 6 is one of a series of reports on the Arizona developed Career Education Curriculum Units. Presented is specific information as to the success of the units in terms of the learner's cognitive, affective, and psychomotor behavior according to expressed performance…
40 CFR Table 37 to Subpart Uuu of... - Requirements for Performance Tests for Bypass Lines
Code of Federal Regulations, 2012 CFR
2012-07-01
... Bypass Lines 37 Table 37 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 37 Table 37 to Subpart UUU of Part 63—Requirements for Performance Tests for Bypass Lines As...
40 CFR Table 37 to Subpart Uuu of... - Requirements for Performance Tests for Bypass Lines
Code of Federal Regulations, 2014 CFR
2014-07-01
... Bypass Lines 37 Table 37 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 37 Table 37 to Subpart UUU of Part 63—Requirements for Performance Tests for Bypass Lines As...
40 CFR Table 37 to Subpart Uuu of... - Requirements for Performance Tests for Bypass Lines
Code of Federal Regulations, 2013 CFR
2013-07-01
... Bypass Lines 37 Table 37 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 37 Table 37 to Subpart UUU of Part 63—Requirements for Performance Tests for Bypass Lines As...
Potency Determination of Antidandruff Shampoos in Nystatin International Unit Equivalents
Anusha Hewage, D. B. G.; Pathirana, W.; Pinnawela, Amara
2008-01-01
A convenient standard microbiological potency determination test for the antidandruff shampoos was developed by adopting the pharmacopoeial microbiological assay procedure of the drug nystatin. A standard curve was drawn consisting of the inhibition zone diameters vs. logarithm of nystatin concentrations in international units using the fungus Saccharomyces cerevisiae (yeast) strain National Collection of Type Culture (NCTC) 1071606 as the test organism. From the standard curve the yeast inhibitory potencies of the shampoos in nystatin international unit equivalents were determined from the respective inhibition zones of the test samples of the shampoos. Under test conditions four shampoo samples showed remarkable fungal inhibitory potencies of 10227, 10731, 12396 and 18211 nystatin international unit equivalents/ml while two shampoo samples had extremely feeble inhibitory potencies 4.07 and 4.37 nystatin international unit equivalents/ml although the latter two products claimed antifungal activity. The potency determination method could be applied to any antidandruff shampoo with any one or a combination of active ingredients. PMID:21394271
Meini, Genny; Dello Russo, Cinzia; Allice, Tiziano; Barresi, Renata; D'Arrigo, Roberta; Falasca, Francesca; Lipsi, Maria Rosaria; Paolucci, Stefania; Zanussi, Stefania; Antonetti, Raffaele; Baldanti, Fausto; Basaglia, Giancarlo; Bruzzone, Bianca; Polilli, Ennio; Ghisetti, Valeria; Pucillo, Leopoldo Paolo; Turriziani, Ombretta; Pirazzoli, Antonella; Navarra, Pierluigi; Zazzi, Maurizio
2016-05-01
Since the HLA-B*57:01 allele is strongly associated with abacavir hypersensitivity reaction, testing for the presence of HLA-B*57:01 is mandatory before administration of abacavir. While HLA-B*57:01 testing is usually provided by pharmacogenetics, genetics or blood transfusion services, clinical virology laboratories can be an optimal opportunity for HLA-B*57:01 testing since they receive blood samples for routine HIV monitoring and have the expertise for convenient and less expensive PCR-based point mutation assays. The Italian HLA-B*57:01 Network gathers accredited clinical virology laboratories offering HLA-B*57:01 testing in Italy with the aim to share protocols, test new methods, develop and maintain external quality assurance (EQA) programs. A panel of 9HLA-B*57:01-positive and 16HLA-B*57:01-negative frozen blood samples were blindly distributed to 10 units including 9 clinical virology laboratories and one reference pharmacology laboratory. Each laboratory was free to use its own routine method for DNA extraction and HLA-B*57:01 testing. DNA was extracted by automated workstations in 6 units and by manual spin columns in 4. Eight units used the Duplicα Real Time HLA-B*57:01 kit by Euroclone and two units used two different PCR homemade protocols. All the 10 units correctly identified all the 25 samples. The first HLA-B*57:01 EQA program run in Italy showed that clinical virology units are equipped and proficient for providing HLA-B*57:01 testing by inexpensive assays easy to integrate into their routine. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Heffner, R.
2000-01-01
This is the Engineering Test Report, AMSU-A2 METSAT Instrument (S/N 108) Acceptance Level Vibration Test of Dec 1999/Jan 2000 (S/O 784077, OC-454), for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).
NASA Technical Reports Server (NTRS)
Valdez, A.
2000-01-01
This is the Engineering Test Report, Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A2, S/N 108, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-29
...] Advancing the Development of Diagnostic Tests and Biomarkers for Tuberculosis; Public Workshop; Request for... workshop entitled ``Advancing the Development of Diagnostic Tests and Biomarkers for Tuberculosis (TB... Tuberculosis in the United States, Committee on the Elimination of Tuberculosis in the United States, Division...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-29
... Treatment, Heating Ventilation and Air Conditioning Systems.'' This new standard provides comprehensive test... Criteria for Air Filtration and Adsorption Units of Normal Atmosphere Cleanup Systems in Light-Water-Cooled... NUCLEAR REGULATORY COMMISSION [NRC-2012-0152] Design, Inspection, and Testing Criteria for Air...
This Federal Radiation Council report includes a full study and analysis of fallout expected in 1963 from nuclear testing that occurred in the past. This report covers fallout expected from Soviet and United States tests through 1962.
Which Fecal Immunochemical Test Should I Choose?
Daly, Jeanette M.; Xu, Yinghui; Levy, Barcey T.
2017-01-01
Objectives: To summarize the fecal immunochemical tests (FITs) available in the United States, the 2014 pathology proficiency testing (PT) program FIT results, and the literature related to the test characteristics of FITs available in the United States to detect advanced adenomatous polyps (AAP) and/or colorectal cancer (CRC). Methods: Detailed review of the Food and Drug Administration’s Clinical Laboratory Improvement Amendments (CLIA) database of fecal occult blood tests, the 2014 FIT PT program results, and the literature related to FIT accuracy. Results: A search of the CLIA database identified 65 FITs, with 26 FITs available for purchase in the United States. Thirteen of these FITs were evaluated on a regular basis by PT programs, with an overall sensitivity of 99.1% and specificity of 99.2% for samples spiked with hemoglobin. Automated FITs had better sensitivity and specificity than CLIA-waived FITs for detection of AAP and CRC in human studies using colonoscopy as the gold standard. Conclusion: Although many FITs are available in the United States, few have been tested in proficiency testing programs. Even fewer have data in humans on sensitivity and specificity for AAP or CRC. Our review indicates that automated FITs have the best test characteristics for AAP and CRC. PMID:28447866
Commercial landscape of noninvasive prenatal testing in the United States.
Agarwal, Ashwin; Sayres, Lauren C; Cho, Mildred K; Cook-Deegan, Robert; Chandrasekharan, Subhashini
2013-06-01
Cell-free fetal DNA-based noninvasive prenatal testing (NIPT) could significantly change the paradigm of prenatal testing and screening. Intellectual property (IP) and commercialization promise to be important components of the emerging debate about clinical implementation of these technologies. We have assembled information about types of testing, prices, turnaround times, and reimbursement of recently launched commercial tests in the United States from the trade press, news articles, and scientific, legal, and business publications. We also describe the patenting and licensing landscape of technologies underlying these tests and ongoing patent litigation in the United States. Finally, we discuss how IP issues may affect clinical translation of NIPT and their potential implications for stakeholders. Fetal medicine professionals (clinicians and researchers), genetic counselors, insurers, regulators, test developers, and patients may be able to use this information to make informed decisions about clinical implementation of current and emerging noninvasive prenatal tests. © 2013 John Wiley & Sons, Ltd.
Commercial Landscape of noninvasive prenatal testing in the United States
Agarwal, Ashwin; Sayres, Lauren C.; Cho, Mildred K.; Cook-Deegan, Robert; Chandrasekharan, Subhashini
2014-01-01
Cell-free fetal DNA-based noninvasive prenatal testing (NIPT) could significantly change the paradigm of prenatal testing and screening. Intellectual property (IP) and commercialization promise to be important components of the emerging debate about clinical implementation of these technologies. We have assembled information about types of testing, prices, turnaround times and reimbursement of recently launched commercial tests in the United States from the trade press, news articles, and scientific, legal, and business publications. We also describe the patenting and licensing landscape of technologies underlying these tests and ongoing patent litigation in the United States. Finally, we discuss how IP issues may affect clinical translation of NIPT and their potential implications for stakeholders. Fetal medicine professionals (clinicians and researchers), genetic counselors, insurers, regulators, test developers and patients may be able to use this information to make informed decisions about clinical implementation of current and emerging noninvasive prenatal tests. PMID:23686656
Oximeter reliability in a subzero environment.
Macnab, A J; Smith, M; Phillips, N; Smart, P
1996-11-01
Pulse oximeters optimize care in the pre-hospital setting. As British Columbia ambulance teams often provide care in subzero temperatures, we conducted a study to determine the reliability of 3 commercially-available portable oximeters in a subzero environment. We hypothesized that there is no significant difference between SaO2 readings obtained using a pulse oximeter at room temperature and a pulse oximeter operating at sub-zero temperatures. Subjects were stable normothermic children in intensive care on Hewlett Packard monitors (control unit) at room temperature. The test units were packed in dry ice in an insulated bin (temperature - 15 degrees C to -30 degrees C) and their sensors placed on the subjects, contralateral to the control sensors. Data were collected simultaneously from test and control units immediately following validation of control unit values by co-oximetry (blood gas). No data were unacceptable. Two units (Propaq 106EC and Nonin 8500N) functioned well to < -15 degrees C, providing data comparable to those obtained from the control unit (p < 0.001). The Siemens Micro O2 did not function at the temperatures tested. Monitor users who require equipment to function in subzero environments (military, Coast Guard, Mountain Rescue) should ensure that function is reliable, and could test units using this method.
Pilot-scale treatability test plan for the 200-BP-5 operable unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This document presents the treatability test plan for pilot-scale pump and treat testing at the 200-BP-5 Operable Unit. This treatability test plan has been prepared in response to an agreement between the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency (EPA), and the State of Washington Department of Ecology (Ecology), as documented in Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement, Ecology et al. 1989a) Change Control Form M-13-93-03 (Ecology et al. 1994) and a recent 200 NPL Agreement Change Control Form (Appendix A). The agreement also requires that, following completion of the activities described in thismore » test plan, a 200-BP-5 Operable Unit Interim Remedial Measure (IRM) Proposed Plan be developed for use in preparing an Interim Action Record of Decision (ROD). The IRM Proposed Plan will be supported by the results of this treatability test plan, as well as by other 200-BP-5 Operable Unit activities (e.g., development of a qualitative risk assessment). Once issued, the Interim Action ROD will specify the interim action(s) for groundwater contamination at the 200-BP-5 Operable Unit. The treatability test approach is to conduct a pilot-scale pump and treat test for each of the two contaminant plumes associated with the 200-BP-5 Operable Unit. Primary contaminants of concern are {sup 99}Tc and {sup 60}Co for underwater affected by past discharges to the 216-BY Cribs, and {sup 90}Sr, {sup 239/240}Pu, and Cs for groundwater affected by past discharges to the 216-B-5 Reverse Well. The purpose of the pilot-scale treatability testing presented in this testplan is to provide the data basis for preparing an IRM Proposed Plan. To achieve this objective, treatability testing must: Assess the performance of groundwater pumping with respect to the ability to extract a significant amount of the primary contaminant mass present in the two contaminant plumes.« less
Rodriguez, Brian D.; Sweetkind, Don; Burton, Bethany L.
2010-01-01
The U.S. Department of Energy (DOE) and the National Nuclear Security Administration (NNSA) at their Nevada Site Office (NSO) are addressing groundwater contamination resulting from historical underground nuclear testing through the Environmental Management program and, in particular, the Underground Test Area (UGTA) project. From 1951 to 1992, 828 underground nuclear tests were conducted at the Nevada Test Site (NTS) northwest of Las Vegas (DOE UGTA, 2003). Most of these tests were conducted hundreds of feet above the groundwater table; however, more than 200 of the tests were near, or within, the water table. This underground testing was limited to specific areas of the NTS including Pahute Mesa, Rainier Mesa/Shoshone Mountain, Frenchman Flat, and Yucca Flat. Volcanic composite units make up much of the area within the Pahute Mesa Corrective Action Unit (CAU) at the NTS, Nevada. The extent of many of these volcanic composite units extends throughout and south of the primary areas of past underground testing at Pahute and Rainier Mesas. As situated, these units likely influence the rate and direction of groundwater flow and radionuclide transport. Currently, these units are poorly resolved in terms of their hydrologic properties introducing large uncertainties into current CAU-scale flow and transport models. In 2007, the U.S. Geological Survey (USGS), in cooperation with DOE and NNSA-NSO acquired three-dimensional (3-D) tensor magnetotelluric data at the NTS in Area 20 of Pahute Mesa CAU. A total of 20 magnetotelluric recording stations were established at about 600-m spacing on a 3-D array and were tied to ER20-6 well and other nearby well control (fig. 1). The purpose of this survey was to determine if closely spaced 3-D resistivity measurements can be used to characterize the distribution of shallow (600- to 1,500-m-depth range) devitrified rhyolite lava-flow aquifers (LFA) and zeolitic tuff confining units (TCU) in areas of limited drill hole control on Pahute Mesa within the Calico Hills zeolitic volcanic composite unit (VCU), an important hydrostratigraphic unit in Area 20. The resistivity response was evaluated and compared with existing well data and hydrogeologic unit tops from the current Pahute Mesa framework model. In 2008, the USGS processed and inverted the magnetotelluric data into a 3-D resistivity model. We interpreted nine depth slices and four west-east profile cross sections of the 3-D resistivity inversion model. This report documents the geologic interpretation of the 3-D resistivity model. Expectations are that spatial variations in the electrical properties of the Calico Hills zeolitic VCU can be detected and mapped with 3-D resistivity, and that these changes correlate to differences in rock permeability. With regard to LFA and TCU, electrical resistivity and permeability are typically related. Tuff confining units will typically have low electrical resistivity and low permeability, whereas LFA will have higher electrical resistivity and zones of higher fracture-related permeability. If expectations are shown to be correct, the method can be utilized by the UGTA scientists to refine the hydrostratigraphic unit (HSU) framework in an effort to more accurately predict radionuclide transport away from test areas on Pahute and Rainier Mesas.
NASA Technical Reports Server (NTRS)
Lebron, Ramon C.; Oliver, Angela C.; Bodi, Robert F.
1991-01-01
Power components hardware in support of the Space Station freedom dc Electric Power System were tested. One type of breadboard hardware tested is the dc Load Converter Unit, which constitutes the power interface between the electric power system and the actual load. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. Three load converters were tested: a series resonant converter, a series inductor switch-mode converter, and a switching full-bridge forward converter. The topology, operation principles, and test results are described, in general. A comparative analysis of the three units is given with respect to efficiency, regulation, short circuit behavior (protection), and transient characteristics.
United States Nuclear Tests, July 1945 through September 1992, December 2000
DOE Office of Scientific and Technical Information (OSTI.GOV)
U.S. Department of Energy, Nevada Operations Office
2000-12-01
This document list chronologically and alphabetically by name all nuclear tests and simultaneous detonations conducted by the United States from July 1945 through September 1992. Revision 15, dated December 2000.
Graphics Processor Units (GPUs)
NASA Technical Reports Server (NTRS)
Wyrwas, Edward J.
2017-01-01
This presentation will include information about Graphics Processor Units (GPUs) technology, NASA Electronic Parts and Packaging (NEPP) tasks, The test setup, test parameter considerations, lessons learned, collaborations, a roadmap, NEPP partners, results to date, and future plans.
Using the Teach-Back Method in Patient Education to Improve Patient Satisfaction.
Centrella-Nigro, Andrea M; Alexander, Catherine
2017-01-01
This quasi-experimental research study used two similar nursing units to test the effects of teach back on Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) scores. A pretest-posttest design tested 24 nurses' knowledge, attitudes, and beliefs about teach back. Education specialists provided a 1-hour teaching session on teach back to all nurses in the intervention unit. A significant improvement in knowledge scores in the pretest-posttest was found using paired t tests (p = .002). Qualitative analysis of nurses' comments demonstrated strong support for teach back in the post-test. The HCAHPS scores were not significantly improved in the intervention unit when compared with the control unit. More research needs to be conducted to determine the effectiveness of teach back on HCAHPS scores. J Contin Educ Nurs. 2017;48(1):47-52. Copyright 2017, SLACK Incorporated.
[Variations in the diagnostic confirmation process between breast cancer mass screening units].
Natal, Carmen; Fernández-Somoano, Ana; Torá-Rocamora, Isabel; Tardón, Adonina; Castells, Xavier
2016-01-01
To analyse variations in the diagnostic confirmation process between screening units, variations in the outcome of each episode and the relationship between the use of the different diagnostic confirmation tests and the lesion detection rate. Observational study of variability of the standardised use of diagnostic and lesion detection tests in 34 breast cancer mass screening units participating in early-detection programmes in three Spanish regions from 2002-2011. The diagnostic test variation ratio in percentiles 25-75 ranged from 1.68 (further appointments) to 3.39 (fine-needle aspiration). The variation ratio in detection rates of benign lesions, ductal carcinoma in situ and invasive cancer were 2.79, 1.99 and 1.36, respectively. A positive relationship between rates of testing and detection rates was found with fine-needle aspiration-benign lesions (R(2): 0.53), fine-needle aspiration-invasive carcinoma (R(2): 0 28), core biopsy-benign lesions (R(2): 0.64), core biopsy-ductal carcinoma in situ (R(2): 0.61) and core biopsy-invasive carcinoma (R(2): 0.48). Variation in the use of invasive tests between the breast cancer screening units participating in early-detection programmes was found to be significantly higher than variations in lesion detection. Units which conducted more fine-needle aspiration tests had higher benign lesion detection rates, while units that conducted more core biopsies detected more benign lesions and cancer. Copyright © 2016 SESPAS. Published by Elsevier Espana. All rights reserved.
Hollow cathode heater development for the Space Station plasma contactor
NASA Technical Reports Server (NTRS)
Soulas, George C.
1993-01-01
A hollow cathode-based plasma contactor has been selected for use on the Space Station. During the operation of the plasma contactor, the hollow cathode heater will endure approximately 12000 thermal cycles. Since a hollow cathode heater failure would result in a plasma contactor failure, a hollow cathode heater development program was established to produce a reliable heater design. The development program includes the heater design, process documents for both heater fabrication and assembly, and heater testing. The heater design was a modification of a sheathed ion thruster cathode heater. Three heaters have been tested to date using direct current power supplies. Performance testing was conducted to determine input current and power requirements for achieving activation and ignition temperatures, single unit operational repeatability, and unit-to-unit operational repeatability. Comparisons of performance testing data at the ignition input current level for the three heaters show the unit-to-unit repeatability of input power and tube temperature near the cathode tip to be within 3.5 W and 44 degrees C, respectively. Cyclic testing was then conducted to evaluate reliability under thermal cycling. The first heater, although damaged during assembly, completed 5985 ignition cycles before failing. Two additional heaters were subsequently fabricated and have completed 3178 cycles to date in an on-going test.
Segments from red blood cell units should not be used for quality testing.
Kurach, Jayme D R; Hansen, Adele L; Turner, Tracey R; Jenkins, Craig; Acker, Jason P
2014-02-01
Nondestructive testing of blood components could permit in-process quality control and reduce discards. Tubing segments, generated during red blood cell (RBC) component production, were tested to determine their suitability as a sample source for quality testing. Leukoreduced RBC components were produced from whole blood (WB) by two different methods: WB filtration and buffy coat (BC). Components and their corresponding segments were tested on Days 5 and 42 of hypothermic storage (HS) for spun hematocrit (Hct), hemoglobin (Hb) content, percentage hemolysis, hematologic indices, and adenosine triphosphate concentration to determine whether segment quality represents unit quality. Segment samples overestimated hemolysis on Days 5 and 42 of HS in both BC- and WB filtration-produced RBCs (p < 0.001 for all). Hct and Hb levels in the segments were also significantly different from the units at both time points for both production methods (p < 0.001 for all). Indeed, for all variables tested different results were obtained from segment and unit samples, and these differences were not consistent across production methods. The quality of samples from tubing segments is not representative of the quality of the corresponding RBC unit. Segments are not suitable surrogates with which to assess RBC quality. © 2013 American Association of Blood Banks.
Stephenson, Jennifer L.; Maluf, Katrina S.
2011-01-01
The paired motor unit analysis provides in vivo estimates of the magnitude of persistent inward currents (PIC) in human motoneurons by quantifying changes in the firing rate (ΔF) of an earlier recruited (reference) motor unit at the time of recruitment and derecruitment of a later recruited (test) motor unit. This study assessed the variability of ΔF estimates, and quantified the dependence of ΔF on the discharge characteristics of the motor units selected for analysis. ΔF was calculated for 158 pairs of motor units recorded from nine healthy individuals during repeated submaximal contractions of the tibialis anterior muscle. The mean (SD) ΔF was 3.7 (2.5) pps (range −4.2 to 8.9 pps). The median absolute difference in ΔF for the same motor unit pair across trials was 1.8 pps, and the minimal detectable change in ΔF required to exceed measurement error was 4.8 pps. ΔF was positively related to the amount of discharge rate modulation in the reference motor unit (r2=0.335; P<0.001), and inversely related to the rate of increase in discharge rate (r2=0.125; P<0.001). A quadratic function provided the best fit for relations between ΔF and the time between recruitment of the reference and test motor units (r2=0.229, P<0.001), the duration of test motor unit activity (r2=0.110, P<0.001), and the recruitment threshold of the test motor unit (r2=0.237, P<0.001). Physiological and methodological contributions to the variability in ΔF estimates of PIC magnitude are discussed, and selection criteria to reduce these sources of variability are suggested for the paired motor unit analysis. PMID:21459110
[Automated analyzer of enzyme immunoassay].
Osawa, S
1995-09-01
Automated analyzers for enzyme immunoassay can be classified by several points of view: the kind of labeled antibodies or enzymes, detection methods, the number of tests per unit time, analytical time and speed per run. In practice, it is important for us consider the several points such as detection limits, the number of tests per unit time, analytical range, and precision. Most of the automated analyzers on the market can randomly access and measure samples. I will describe the recent advance of automated analyzers reviewing their labeling antibodies and enzymes, the detection methods, the number of test per unit time and analytical time and speed per test.
40 CFR Table 37 to Subpart Uuu of... - Requirements for Performance Tests for Bypass Lines
Code of Federal Regulations, 2010 CFR
2010-07-01
... Bypass Lines 37 Table 37 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION...: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 37 Table 37 to Subpart UUU of Part 63—Requirements for Performance Tests for Bypass Lines As stated in § 63...
40 CFR Table 37 to Subpart Uuu of... - Requirements for Performance Tests for Bypass Lines
Code of Federal Regulations, 2011 CFR
2011-07-01
... Bypass Lines 37 Table 37 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION...: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 37 Table 37 to Subpart UUU of Part 63—Requirements for Performance Tests for Bypass Lines As stated in § 63...
Poirot, Jean-Louis; Gangneux, Jean-Pierre; Fischer, Alain; Malbernard, Mireille; Challier, Svetlana; Laudinet, Nicolas; Bergeron, Vance
2007-09-01
Invasive aspergillosis is one of the most lethal airborne dangers for immune-suppressed subjects. Providing patient protection from such airborne threats requires costly and high-maintenance facilities. We herein evaluate a new self-contained mobile unit as an alternative for creating a patient protective environment. Airborne contamination levels were monitored for different simulated scenarios and under actual clinical conditions. Functional tests were used to challenge the unit under adverse conditions, and a preliminary clinical study with patients and staff present was performed at 2 different French hospitals. Functional tests demonstrated that the unit can rapidly decontaminate air in the protected zone created by the unit and in the surrounding room. In addition, the protected zone is not sensitive to large disturbances that occur in the room. The clinical study included 4 patients with 150 accumulated days of testing. The protected zone created by the unit systematically provided an environment with undetectable airborne fungal levels (ie, <1 CFU/m(3)) regardless of the levels in the room or corridor (P < .01). These tests show that the unit can be used to create a mobile protective environment for immune-suppressed patients in a standard hospital setting.
Novel exposure units for at-home personalized testing of electromagnetic sensibility.
Huss, Anke; Murbach, Manuel; van Moorselaar, Imke; Kuster, Niels; van Strien, Rob; Kromhout, Hans; Vermeulen, Roel; Slottje, Pauline
2016-01-01
Previous experimental studies on electromagnetic hypersensitivity have been criticized regarding inflexibility of choice of exposure and of study locations. We developed and tested novel portable exposure units that can generate different output levels of various extremely low frequency magnetic fields (ELF-MF; 50 Hz field plus harmonics) and radiofrequency electromagnetic fields (RF-EMF). Testing was done with a group of healthy volunteers (n = 25 for 5 ELF-MF and n = 25 for 5 RF-EMF signals) to assess if units were indeed able to produce double-blind exposure conditions. Results substantiated that double-blind conditions were met; on average participants scored 50.6% of conditions correct on the ELF-MF, and 50.0% on the RF-EMF unit, which corresponds to guessing probability. No cues as to exposure conditions were reported. We aim to use these units in a future experiment with subjects who wish to test their personal hypothesis of being able to sense or experience when being exposed to EMF. The new units allow for a high degree of flexibility regarding choice of applied electromagnetic signal, output power level and location (at home or another environment of subjects' choosing). © 2015 Wiley Periodicals, Inc.
Predicting Envelope Leakage in Attached Dwellings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Faakye, O.; Arena, L.; Griffiths, D.
2013-07-01
The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, andmore » control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, H.; Higuchi, T.; Nishioki, N.
1997-01-01
A dual tunneling-unit scanning tunneling microscope (DTU STM) was developed for nm order length measurement with wide scan range. The crystalline lattice of highly oriented pyrolitic graphite (HOPG) was used as reference scale. A reference unit was set up on top of a test unit. The reference sample holder and the probe tip of test unit were attached to one single XY scanner on either surface, while the test sample holder was open. This enables simultaneous acquisition of wide images of HOPG and test sample. The length in test sample image was measured by counting the number of HOPG lattices.more » An inchworm actuator and an impact drive mechanism were introduced to roughly position probe tips. The XY scanner was designed to be elastic to eliminate image distortion. Some comparison experiments using two HOPG chips were carried out in air. The DTU STM is confirmed to be a stable and more powerful device for length measurement which has nanometer accuracy when covering a wide scan range up to several micrometers, and is capable of measuring comparatively large and heavy samples. {copyright} {ital 1997 American Vacuum Society.}« less
ChemCam Mast Unit Being Prepared for Laser Firing
2010-12-23
Researchers prepare for a test of the Chemistry and Camera ChemCam instrument that will fly on NASA Mars Science Laboratory mission; researchers are preparing the instrument mast unit for a laser firing test.
United States Nuclear Tests, July 1945 through September 1992, September 2015
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
This document lists chronologically and alphabetically by name all nuclear tests and simultaneous detonations conducted by the United States from July 1945 through September 1992. This is Revision 16, dated September 2015.
Asphalt and Wood Shingling. Roofing Workbook and Tests.
ERIC Educational Resources Information Center
Brown, Arthur
This combination workbook and set of tests contains materials on asphalt and wood shingling that have been designed to be used by those studying to enter the roofing and waterproofing trade. It consists of seven instructional units and seven accompanying objective tests. Covered in the individual units are the following topics: shingling…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-10
... Whitney A Subsidiary of United Technologies Corporation Far Group and Experimental Test Group East... Technologies Corporation, FAR Group and Experimental Test Group, supplies/supports and operates as an extension... Test Group. The amended notice applicable to TA-W-75,152 is hereby issued as follows: ``All workers of...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-08
... test units'' from a supplier located in China.\\16\\ Share indicated that it had offered only three units... certain apparent discrepancies between the application, test report, and equipment certification as to the... description of the product: ``computer peripheral for preprocessing data.'' \\25\\ Similarly, the test report...
Astronaut Bruce McCandless tests astronaut maneuvering unit
1973-08-16
S72-30704 (1972) --- Astronaut Bruce McCandless II, backup pilot for Skylab 2, tests the balance and control of an astronaut maneuvering unit (AMU) test model at Martin Marietta Corporation's Denver division. The jet-powered backpack can fly for 30 minutes and can be worn over normal clothing or spacesuit. Photo credit: NASA
14 CFR 33.96 - Engine tests in auxiliary power unit (APU) mode.
Code of Federal Regulations, 2011 CFR
2011-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.96 Engine tests in auxiliary power unit (APU) mode. If the engine is designed with a propeller brake which...) Ground locking: A total of 45 hours with the propeller brake engaged in a manner which clearly...
14 CFR 33.96 - Engine tests in auxiliary power unit (APU) mode.
Code of Federal Regulations, 2010 CFR
2010-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.96 Engine tests in auxiliary power unit (APU) mode. If the engine is designed with a propeller brake which...) Ground locking: A total of 45 hours with the propeller brake engaged in a manner which clearly...
14 CFR 33.96 - Engine tests in auxiliary power unit (APU) mode.
Code of Federal Regulations, 2012 CFR
2012-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.96 Engine tests in auxiliary power unit (APU) mode. If the engine is designed with a propeller brake which...) Ground locking: A total of 45 hours with the propeller brake engaged in a manner which clearly...
14 CFR 33.96 - Engine tests in auxiliary power unit (APU) mode.
Code of Federal Regulations, 2014 CFR
2014-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.96 Engine tests in auxiliary power unit (APU) mode. If the engine is designed with a propeller brake which...) Ground locking: A total of 45 hours with the propeller brake engaged in a manner which clearly...
14 CFR 33.96 - Engine tests in auxiliary power unit (APU) mode.
Code of Federal Regulations, 2013 CFR
2013-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.96 Engine tests in auxiliary power unit (APU) mode. If the engine is designed with a propeller brake which...) Ground locking: A total of 45 hours with the propeller brake engaged in a manner which clearly...
Unit: Sticking Together, First Trial Materials, Inspection Set.
ERIC Educational Resources Information Center
Australian Science Education Project, Toorak, Victoria.
These materials, including teacher's guide, student test booklet and laboratory guide, student workbook, test booklet, and a booklet explaining the answers to the questions in the test booklet, are first trial versions of a unit that will form part of the Australian Science Education Project instructional materials for grades seven through ten.…
Initial closed operation of the CELSS Test Facility Engineering Development Unit
NASA Technical Reports Server (NTRS)
Kliss, M.; Blackwell, C.; Zografos, A.; Drews, M.; MacElroy, R.; McKenna, R.; Heyenga, A. G.
2003-01-01
As part of the NASA Advanced Life Support Flight Program, a Controlled Ecological Life Support System (CELSS) Test Facility Engineering Development Unit has been constructed and is undergoing initial operational testing at NASA Ames Research Center. The Engineering Development Unit (EDU) is a tightly closed, stringently controlled, ground-based testbed which provides a broad range of environmental conditions under which a variety of CELSS higher plant crops can be grown. Although the EDU was developed primarily to provide near-term engineering data and a realistic determination of the subsystem and system requirements necessary for the fabrication of a comparable flight unit, the EDU has also provided a means to evaluate plant crop productivity and physiology under controlled conditions. This paper describes the initial closed operational testing of the EDU, with emphasis on the hardware performance capabilities. Measured performance data during a 28-day closed operation period are compared with the specified functional requirements, and an example of inferring crop growth parameters from the test data is presented. Plans for future science and technology testing are also discussed. Published by Elsevier Science Ltd on behalf of COSPAR.
Assessing Situational Awareness in Task Force XXI.
1997-06-01
information dominance over the enemy and that units equipped with greater situational awareness will fight more successfully than units without the added capability. In an effort to test this hypothesis the Army conducted an Advanced Warfighter Experiment (AWE) which began at Ft. Hood, TX and culminated in a focused rotation at the National Training Center, Ft. Irwin, CA. Although many initiatives in the area of information dominance were tested in the AWE, the centerpiece of the program was a test case unit designated as Task Force Twenty-One (TF
CGBA, Pilot Kent Rominger films HHDTC units in Spacelab
1995-11-05
STS073-131-014 (20 October-5 November 1995) --- Astronaut Kent V. Rominger, STS-73 pilot, uses a camcorder to record progress in the Hand-Held Diffusion Test Cell (HHDTC) experiment. This test dealt with crystal growth by liquid-to-liquid diffusion. Four HHDTC units containing four test cells each produced protein crystals by diffusing one liquid to another. Rominger joined four other NASA astronauts and two guest researchers for 16 days of in-space United States Microgravity Laboratory 2 (USML-2) research aboard the Space Shuttle Columbia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-03-28
The study, conducted by Babcock and Wilcox, was funded by the U.S. Trade and Development agency on behalf of Enelven. In order to maximize generated power output and minimize operating costs at Planta Ramon Laguna, tests were done to evaluate the condition of equipment at the plant. In order to identify any damage and determine the operating output of each unit, assessments were done of the furnaces, boilers, generators and boiler feed pumps being used in the plant. The report presents the results of these tests. This is the last of three volumes and it is divided into the followingmore » sections: (1) Condition Assessment of Unit RL-10 Turbine-Generator; (2) Condition Assessment of Unit RL-10 and RL-11 Boiler Feed Pumps.« less
Moore, Andrew; Nelson, Christina; Molins, Claudia; Mead, Paul; Schriefer, Martin
2016-07-01
In the United States, Lyme disease is caused by Borrelia burgdorferi and transmitted to humans by blacklegged ticks. Patients with an erythema migrans lesion and epidemiologic risk can receive a diagnosis without laboratory testing. For all other patients, laboratory testing is necessary to confirm the diagnosis, but proper interpretation depends on symptoms and timing of illness. The recommended laboratory test in the United States is 2-tiered serologic analysis consisting of an enzyme-linked immunoassay or immunofluorescence assay, followed by reflexive immunoblotting. Sensitivity of 2-tiered testing is low (30%-40%) during early infection while the antibody response is developing (window period). For disseminated Lyme disease, sensitivity is 70%-100%. Specificity is high (>95%) during all stages of disease. Use of other diagnostic tests for Lyme disease is limited. We review the rationale behind current US testing guidelines, appropriate use and interpretation of tests, and recent developments in Lyme disease diagnostics.
Delivery of Colloid Micro-Newton Thrusters for the Space Technology 7 Mission
NASA Technical Reports Server (NTRS)
Ziemer, John K.; Randolph, Thomas M.; Franklin, Garth W.; Hruby, Vlad; Spence, Douglas; Demmons, Nathaniel; Roy, Thomas; Ehrbar, Eric; Zwahlen, Jurg; Martin, Roy;
2008-01-01
Two flight-qualified clusters of four Colloid Micro-Newton Thruster (CMNT) systems have been delivered to the Jet Propulsion Laboratory (JPL). The clusters will provide precise spacecraft control for the drag-free technology demonstration mission, Space Technology 7 (ST7). The ST7 mission is sponsored by the NASA New Millennium Program and will demonstrate precision formation flying technologies for future missions such as the Laser Interferometer Space Antenna (LISA) mission. The ST7 disturbance reduction system (DRS) will be on the ESA LISA Pathfinder spacecraft using the European gravitational reference sensor (GRS) as part of the ESA LISA Technology Package (LTP). Developed by Busek Co. Inc., with support from JPL in design and testing, the CMNT has been developed over the last six years into a flight-ready and flight-qualified microthruster system, the first of its kind. Recent flight-unit qualification tests have included vibration and thermal vacuum environmental testing, as well as performance verification and acceptance tests. All tests have been completed successfully prior to delivery to JPL. Delivery of the first flight unit occurred in February of 2008 with the second unit following in May of 2008. Since arrival at JPL, the units have successfully passed through mass distribution, magnetic, and EMI/EMC measurements and tests as part of the integration and test (I&T) activities including the integrated avionics unit (IAU). Flight software sequences have been tested and validated with the full flight DRS instrument successfully to the extent possible in ground testing, including full functional and 72 hour autonomous operations tests. Delivery of the cluster assemblies along with the IAU to ESA for integration into the LISA Pathfinder spacecraft is planned for the summer of 2008 with a planned launch and flight demonstration in late 2010.
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Haag, Thomas; Huang, Wensheng; Shastry, Rohit; Pinero, Luis; Peterson, Todd; Mathers, Alex
2012-01-01
NASA Science Mission Directorate's In-Space Propulsion Technology Program is sponsoring the development of a 3.5 kW-class engineering development unit Hall thruster for implementation in NASA science and exploration missions. NASA Glenn and Aerojet are developing a high fidelity high voltage Hall accelerator that can achieve specific impulse magnitudes greater than 2,700 seconds and xenon throughput capability in excess of 300 kilograms. Performance, plume mappings, thermal characterization, and vibration tests of the high voltage Hall accelerator engineering development unit have been performed. Performance test results indicated that at 3.9 kW the thruster achieved a total thrust efficiency and specific impulse of 58%, and 2,700 sec, respectively. Thermal characterization tests indicated that the thruster component temperatures were within the prescribed material maximum operating temperature limits during full power thruster operation. Finally, thruster vibration tests indicated that the thruster survived the 3-axes qualification full-level random vibration test series. Pre and post-vibration test performance mappings indicated almost identical thruster performance. Finally, an update on the development progress of a power processing unit and a xenon feed system is provided.
Mobile HIV screening in Cape Town, South Africa: clinical impact, cost and cost-effectiveness.
Bassett, Ingrid V; Govindasamy, Darshini; Erlwanger, Alison S; Hyle, Emily P; Kranzer, Katharina; van Schaik, Nienke; Noubary, Farzad; Paltiel, A David; Wood, Robin; Walensky, Rochelle P; Losina, Elena; Bekker, Linda-Gail; Freedberg, Kenneth A
2014-01-01
Mobile HIV screening may facilitate early HIV diagnosis. Our objective was to examine the cost-effectiveness of adding a mobile screening unit to current medical facility-based HIV testing in Cape Town, South Africa. We used the Cost Effectiveness of Preventing AIDS Complications International (CEPAC-I) computer simulation model to evaluate two HIV screening strategies in Cape Town: 1) medical facility-based testing (the current standard of care) and 2) addition of a mobile HIV-testing unit intervention in the same community. Baseline input parameters were derived from a Cape Town-based mobile unit that tested 18,870 individuals over 2 years: prevalence of previously undiagnosed HIV (6.6%), mean CD4 count at diagnosis (males 423/µL, females 516/µL), CD4 count-dependent linkage to care rates (males 31%-58%, females 49%-58%), mobile unit intervention cost (includes acquisition, operation and HIV test costs, $29.30 per negative result and $31.30 per positive result). We conducted extensive sensitivity analyses to evaluate input uncertainty. Model outcomes included site of HIV diagnosis, life expectancy, medical costs, and the incremental cost-effectiveness ratio (ICER) of the intervention compared to medical facility-based testing. We considered the intervention to be "very cost-effective" when the ICER was less than South Africa's annual per capita Gross Domestic Product (GDP) ($8,200 in 2012). We projected that, with medical facility-based testing, the discounted (undiscounted) HIV-infected population life expectancy was 132.2 (197.7) months; this increased to 140.7 (211.7) months with the addition of the mobile unit. The ICER for the mobile unit was $2,400/year of life saved (YLS). Results were most sensitive to the previously undiagnosed HIV prevalence, linkage to care rates, and frequency of HIV testing at medical facilities. The addition of mobile HIV screening to current testing programs can improve survival and be very cost-effective in South Africa and other resource-limited settings, and should be a priority.
The missing link? Testing a schema account of unitization.
Tibon, Roni; Greve, Andrea; Henson, Richard
2018-05-09
Unitization refers to the creation of a new unit from previously distinct items. The concept of unitization has been used to explain how novel pairings between items can be remembered without requiring recollection, by virtue of new, item-like representations that enable familiarity-based retrieval. We tested an alternative account of unitization - a schema account - which suggests that associations between items can be rapidly assimilated into a schema. We used a common operationalization of "unitization" as the difference between two unrelated words being linked by a definition, relative to two words being linked by a sentence, during an initial study phase. During the following relearning phase, a studied word was re-paired with a new word, either related or unrelated to the original associate from study. In a final test phase, memory for the relearned associations was tested. We hypothesized that, if unitized representations act like schemas, then we would observe some generalization to related words, such that memory would be better in the definition than sentence condition for related words, but not for unrelated words. Contrary to the schema hypothesis, evidence favored the null hypothesis of no difference between definition and sentence conditions for related words (Experiment 1), even when each cue was associated with multiple associates, indicating that the associations can be generalized (Experiment 2), or when the schematic information was explicitly re-activated during Relearning (Experiment 3). These results suggest that unitized associations do not generalize to accommodate new information, and therefore provide evidence against the schema account.
Comparison of the heat generation of light curing units.
Bagis, Bora; Bagis, Yildirim; Ertas, Ertan; Ustaomer, Seda
2008-02-01
The aim of this study was to evaluate the heat generation of three different types of light curing units. Temperature increases were recorded from a distance of 1 mm from a thermocouple to the tip of three different types of light curing units including one quartz-tungsten halogen (QTH), one plasma arc (PAC), and one light emitting diode (LED) unit. An experimental model was designed to fix the 1 mm distance between the tip of the light curing units and the thermocouple wire. Temperature changes were recorded in 10 second intervals up to 40 seconds. (10, 20, 30, and 40 seconds). Temperature measurements were repeated three times for every light curing unit after a one hour standby period. Statistical analysis of the results was performed using the analysis of variance (ANOVA) and the Bonferroni Test. The highest temperature rises (54.4+/-1.65 degrees C) occurred during activation of a PAC light curing unit for every test period (p<.05). The least temperature increase (11.8+/-1.3 degrees C) occurred with a LED curing unit for each tested period except for the measurement of the temperature rise using the QTH curing unit at the tenth second interval (p<.05). These results indicate the choice of light activation unit and curing time is important when polymerizing light activated resin based restorations to avoid any thermal damage to the pulp.
ERIC Educational Resources Information Center
Gavin, M. Katherine; Casa, Tutita M.; Firmender, Janine M.; Carroll, Susan R.
2013-01-01
The goal of Project M2 was to develop and field-test challenging geometry and measurement units for K-2 students. The units were developed using recommendations from gifted, mathematics, and early childhood education. This article reports on achievement results for students in Grade 1 at 12 diverse sites in four states using the Iowa Tests of…
The Tapwater Tour. The Hands-On Test Kit & Mini Curriculum for Exploring Drinking Water.
ERIC Educational Resources Information Center
LaMotte Co., Chestertown, MD.
The goal of this mini-curriculum is for students to discover what drinking water really is. Five units are designed to be presented as a lecture and to allow 30 to 40 students to perform every procedure, each testing their own tap water sample. Games are provided in each section to reinforce the concepts presented in each unit. Unit 1 introduces…
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 13 2014-07-01 2014-07-01 false Requirements for Performance Tests for Organic HAP Emissions From Catalytic Reforming Units 18 Table 18 to Subpart UUU of Part 63 Protection of... Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 18 Table 18 to Subpart UUU of Part 63—Requirements for...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Requirements for Performance Tests for Organic HAP Emissions From Catalytic Reforming Units 18 Table 18 to Subpart UUU of Part 63 Protection of... Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 18 Table 18 to Subpart UUU of Part 63—Requirements for...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 13 2012-07-01 2012-07-01 false Requirements for Performance Tests for Organic HAP Emissions From Catalytic Reforming Units 18 Table 18 to Subpart UUU of Part 63 Protection of... Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 18 Table 18 to Subpart UUU of Part 63—Requirements for...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-04
... take a practical test after passing a knowledge test. For example, 14 CFR 61.39(a)(1) gives a person 24... operations. SFAR 100-2 also continues to allow FSDOs to accept expired airman written test reports for certain practical tests from U.S. personnel who are assigned outside the United States in support of U.S...
Disinfection of contaminated water by using solar irradiation.
Caslake, Laurie F; Connolly, Daniel J; Menon, Vilas; Duncanson, Catriona M; Rojas, Ricardo; Tavakoli, Javad
2004-02-01
Contaminated water causes an estimated 6 to 60 billion cases of gastrointestinal illness annually. The majority of these cases occur in rural areas of developing nations where the water supply remains polluted and adequate sanitation is unavailable. A portable, low-cost, and low-maintenance solar unit to disinfect unpotable water has been designed and tested. The solar disinfection unit was tested with both river water and partially processed water from two wastewater treatment plants. In less than 30 min in midday sunlight, the unit eradicated more than 4 log10 U (99.99%) of bacteria contained in highly contaminated water samples. The solar disinfection unit has been field tested by Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente in Lima, Peru. At moderate light intensity, the solar disinfection unit was capable of reducing the bacterial load in a controlled contaminated water sample by 4 log10 U and disinfected approximately 1 liter of water in 30 min.
[Is the use of plastic capillary tubes justified for blood gases analysis?].
Daurès, Marie-Françoise; Bozonnat, Marie-Cécile; Cristol, Jean-Paul
2011-01-01
Some clinical units, such as neonatal or maternity units, preferentially use capillary tubes when analysing blood gases. Using glass tubes is delicate and nurses must recollect blood when breaking. In order to eliminate this problem, we tested flexible, plastic capillary tubes in both the above mentionned units and in our biochemistry laboratory. Each unit, where glass tubes were habitually used, tested 200 flexible, plastic capillary tubes. In addition, the nursing staffed filled out a questionnaire concerned tube usage. Both units clearly preferred using the flexible tubes. In the laboratory, results for blood gas analyses were compared between rigid glass and flexible plastic capillary tubes for 112 patients. Concordance tests did not showed significant differences between the two tube types, except for hematocrit and total haemoglobin. A questionnaire was also presented to the lab technician, who confirmed the easier usability of plastic capillary tubes.
NASA Astrophysics Data System (ADS)
Slykhuis, David A.
This research project examined the efficacy of an online microcomputer-based laboratory based (MBL) physics unit. One hundred and fifty physics students from five high schools in North Carolina were divided into online and classroom groups. The classroom group completed the MBL unit in small groups with assistance from their teachers. The online groups completed the MBL unit in small groups using a website designed for this project for guidance. Pre- and post-unit content specific tests and surveys were given. Statistical analysis of the content tests showed significant development of conceptual understanding by the online group over the course of the unit. There was not a significant difference between the classroom and online group with relation to the amount of conceptual understanding developed. Correlations with post-test achievement showed that pre-test scores and math background were the most significant correlates with success. Computer related variables, such as computer comfort and online access, were only mildly correlated with the online group. Students' views about the nature of physics were not well developed prior to the unit and did not significantly change over the course of the unit. Examination of the students' physics conceptions after instruction revealed common alternative conceptions such as confusing position and velocity variables and incorrect interpretations of graphical features such as slope.
Accelerated testing of module-level power electronics for long-term reliability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flicker, Jack David; Tamizhmani, Govindasamy; Moorthy, Mathan Kumar
This work has applied a suite of long-term-reliability accelerated tests to a variety of module-level power electronics (MLPE) devices (such as microinverters and optimizers) from five different manufacturers. This dataset is one of the first (only the paper by Parker et al. entitled “Dominant factors affecting reliability of alternating current photovoltaic modules,” in Proc. 42nd IEEE Photovoltaic Spec. Conf., 2015, is reported for reliability testing in the literature), as well as the largest, experimental sets in public literature, both in the sample size (five manufacturers including both dc/dc and dc/ac units and 20 units for each test) and the numbermore » of experiments (six different experimental test conditions) for MLPE devices. The accelerated stress tests (thermal cycling test per IEC 61215 profile, damp heat test per IEC 61215 profile, and static temperature tests at 100 and 125 °C) were performed under powered and unpowered conditions. The first independent long-term experimental data regarding damp heat and grid transient testing, as well as the longest term (>9 month) testing of MLPE units reported in the literature for thermal cycling and high-temperature operating life, are included in these experiments. Additionally, this work is the first to show in situ power measurements, as well as periodic efficiency measurements over a series of experimental tests, demonstrating whether certain tests result in long-term degradation or immediate catastrophic failures. Lastly, the result of this testing highlights the performance of MLPE units under the application of several accelerated environmental stressors.« less
Accelerated testing of module-level power electronics for long-term reliability
Flicker, Jack David; Tamizhmani, Govindasamy; Moorthy, Mathan Kumar; ...
2016-11-10
This work has applied a suite of long-term-reliability accelerated tests to a variety of module-level power electronics (MLPE) devices (such as microinverters and optimizers) from five different manufacturers. This dataset is one of the first (only the paper by Parker et al. entitled “Dominant factors affecting reliability of alternating current photovoltaic modules,” in Proc. 42nd IEEE Photovoltaic Spec. Conf., 2015, is reported for reliability testing in the literature), as well as the largest, experimental sets in public literature, both in the sample size (five manufacturers including both dc/dc and dc/ac units and 20 units for each test) and the numbermore » of experiments (six different experimental test conditions) for MLPE devices. The accelerated stress tests (thermal cycling test per IEC 61215 profile, damp heat test per IEC 61215 profile, and static temperature tests at 100 and 125 °C) were performed under powered and unpowered conditions. The first independent long-term experimental data regarding damp heat and grid transient testing, as well as the longest term (>9 month) testing of MLPE units reported in the literature for thermal cycling and high-temperature operating life, are included in these experiments. Additionally, this work is the first to show in situ power measurements, as well as periodic efficiency measurements over a series of experimental tests, demonstrating whether certain tests result in long-term degradation or immediate catastrophic failures. Lastly, the result of this testing highlights the performance of MLPE units under the application of several accelerated environmental stressors.« less
The purpose of this SOP is to describe the procedures for the periodic calibration and leak testing of Harvard particulate matter (PM) impactor units. This procedure applies directly to the calibration and leak testing of Harvard PM impactor units used during the Arizona NHEXAS ...
Test Format and the Variation of Gender Achievement Gaps within the United States
ERIC Educational Resources Information Center
Reardon, Sean; Fahle, Erin; Kalogrides, Demetra; Podolsky, Anne; Zarate, Rosalia
2016-01-01
Prior research demonstrates the existence of gender achievement gaps and the variation in the magnitude of these gaps across states. This paper characterizes the extent to which the variation of gender achievement gaps on standardized tests across the United States can be explained by differing state accountability test formats. A comprehensive…
The purpose of this SOP is to describe the procedures for the periodic calibration and leak testing of Harvard particulate matter (PM) impactor units. This procedure applies directly to the calibration and leak testing of Harvard PM impactor units used during the Arizona NHEXAS ...
Software Measurement Guidebook. Version 02.00.02
1992-12-01
Compatibility Testing Process .............................. 9-5 Figure 9-3. Development Effort Planning Curve ................................. 9-7 Figure 10-1...requirements, design, code, and test and for analyzing this data. "* Proposal Manager. The person responsible for describing and supporting the estimated...designed, build/elease ranges, variances, and comparisons size growth; costs; completions; and content, units completing test , units with historical
Solar Heating Systems: Progress Checks & Tests Manual.
ERIC Educational Resources Information Center
Green, Joanne; And Others
This manual contains Progress Checks and Tests for use in a Solar Heating Systems curriculum (see note). It contains master copies of all Progress Checks and Unit Tests accompanying the curriculum, organized by unit. (The master copies are to be duplicated by each school so that adequate copies are available for student use in a self-paced student…
Testing to Characterize the Advanced Stirling Radioisotope Generator Engineering Unit
NASA Technical Reports Server (NTRS)
Lewandowski, Edward; Schreiber, Jeffrey
2010-01-01
The Advanced Stirling Radioisotope Generator (ASRG), a high efficiency generator, is being considered for space missions. Lockheed Martin designed and fabricated an engineering unit (EU), the ASRG EU, under contract to the Department of Energy. This unit is currently undergoing extended operation testing at the NASA Glenn Research Center to generate performance data and validate life and reliability predictions for the generator and the Stirling convertors. It has also undergone performance tests to characterize generator operation while varying control parameters and system inputs. This paper summarizes and explains test results in the context of designing operating strategies for the generator during a space mission and notes expected differences between the EU performance and future generators.
Verification of Wind Measurement with Mobile Laser Doppler System
DOT National Transportation Integrated Search
1977-09-01
The Lockheed Mobile Atmospheric Unit is a laser Doppler velocimeter system designed for the remote measurement of the three components of atmospheric wind. The unit was tested at the National Oceanic and Atmospheric Administration Table Mountain Test...
A Systems Approach to Costing in the Blood Bank
Delon, Gerald L.; Smalley, Harold E.
1969-01-01
A macroscopic approach to departmental cost finding is combined with a microscopic approach to the weighting of laboratory tests in a mathematical model which, when incorporated into a relative unit value format, yields unit costs for such tests under a wide variety of operational conditions. The task of updating such costs to reflect changing conditions can be facilitated by a computer program incorporating the capability of pricing the various tests to achieve any desired profit or loss or to break even. Among other potential uses of such a technique, the effects on unit cost per test caused by increasing or decreasing the number of technicians or the volume of tests can be systematically examined, and pricing can be updated each year as hospital costs change. PMID:5799486
The modern rotor aerodynamic limits survey: A report and data survey
NASA Technical Reports Server (NTRS)
Cross, J.; Brilla, J.; Kufeld, R.; Balough, D.
1993-01-01
The first phase of the Modern Technology Rotor Program, the Modern Rotor Aerodynamic Limits Survey, was a flight test conducted by the United States Army Aviation Engineering Flight Activity for NASA Ames Research Center. The test was performed using a United States Army UH-60A Black Hawk aircraft and the United States Air Force HH-60A Night Hawk instrumented main-rotor blade. The primary purpose of this test was to gather high-speed, steady-state, and maneuvering data suitable for correlation purposes with analytical prediction tools. All aspects of the data base, flight-test instrumentation, and test procedures are presented and analyzed. Because of the high volume of data, only select data points are presented. However, access to the entire data set is available upon request.
Symbolic Execution Enhanced System Testing
NASA Technical Reports Server (NTRS)
Davies, Misty D.; Pasareanu, Corina S.; Raman, Vishwanath
2012-01-01
We describe a testing technique that uses information computed by symbolic execution of a program unit to guide the generation of inputs to the system containing the unit, in such a way that the unit's, and hence the system's, coverage is increased. The symbolic execution computes unit constraints at run-time, along program paths obtained by system simulations. We use machine learning techniques treatment learning and function fitting to approximate the system input constraints that will lead to the satisfaction of the unit constraints. Execution of system input predictions either uncovers new code regions in the unit under analysis or provides information that can be used to improve the approximation. We have implemented the technique and we have demonstrated its effectiveness on several examples, including one from the aerospace domain.
Field Testing of Compartmentalization Methods for Multifamily Construction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ueno, K.; Lstiburek, J.
The 2012 IECC has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure for both single-family and multifamily construction in Climate Zones 3-8. Other programs (LEED, ASHRAE 189, ASHRAE 62.2) have similar or tighter compartmentalization requirements, driving the need for easier and more effective methods of compartmentalization in multifamily buildings. Builders and practitioners have found that fire-resistance rated wall assemblies are a major source of difficulty in air sealing/compartmentalization, particularly in townhouse construction. This problem is exacerbated when garages are “tucked in” to the units and living space is located over the garages. In thismore » project, Building Science Corporation examined the taping of exterior sheathing details to improve air sealing results in townhouse and multifamily construction, when coupled with a better understanding of air leakage pathways. Current approaches are cumbersome, expensive, time consuming, and ineffective; these details were proposed as a more effective and efficient method. The effectiveness of these air sealing methods was tested with blower door testing, including “nulled” or “guarded” testing (adjacent units run at equal test pressure to null out inter-unit air leakage, or “pressure neutralization”). Pressure diagnostics were used to evaluate unit-to-unit connections and series leakage pathways (i.e., air leakage from exterior, into the fire-resistance rated wall assembly, and to the interior).« less
Potable water recovery for spacecraft application by electrolytic pretreatment/air evaporation
NASA Technical Reports Server (NTRS)
Wells, G. W.
1975-01-01
A process for the recovery of potable water from urine using electrolytic pretreatment followed by distillation in a closed-cycle air evaporator has been developed and tested. Both the electrolytic pretreatment unit and the air evaporation unit are six-person, flight-concept prototype, automated units. Significantly extended wick lifetimes have been achieved in the air evaporation unit using electrolytically pretreated, as opposed to chemically pretreated, urine feed. Parametric test data are presented on product water quality, wick life, process power, maintenance requirements, and expendable requirements.
Testing of motor unit synchronization model for localized muscle fatigue.
Naik, Ganesh R; Kumar, Dinesh K; Yadav, Vivek; Wheeler, Katherine; Arjunan, Sridhar
2009-01-01
Spectral compression of surface electromyogram (sEMG) is associated with onset of localized muscle fatigue. The spectral compression has been explained based on motor unit synchronization theory. According to this theory, motor units are pseudo randomly excited during muscle contraction, and with the onset of muscle fatigue the recruitment pattern changes such that motor unit firings become more synchronized. While this is widely accepted, there is little experimental proof of this phenomenon. This paper has used source dependence measures developed in research related to independent component analysis (ICA) to test this theory.
High Power Alternator Test Unit (ATU) Electrical System Test
NASA Technical Reports Server (NTRS)
Birchenough, Arthur; Hervol, David
2007-01-01
The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, OH was used to simulate the operating conditions and evaluate the performance of the ATU and it s interaction with various LPSF components in accordance with the JIMO AC Power System Requirements. The testing was carried out at the breadboard development level. Results of these tests will be used for the development and validation of analytical models for performance and lifetime prediction.
Kirsch, L E; Nguyen, L; Moeckly, C S; Gerth, R
1997-01-01
Helium leak rate measurements were quantitatively correlated to the probability of microbial ingress for rubber-stoppered glass vials subjected to immersion challenge. Standard 10-mL tubing glass vials were modified by inserting micropipettes of various sizes (0.1 to 10 microns nominal diameter) into a side wall hole and securing them with epoxy. Butyl rubber closures and aluminum crimps were used to seal the vials. The test units were sealed in a helium-filled glove bag, then the absolute helium leak rates were determined. The test units were disassembled, filled with media, resealed, and autoclaved. The test units were thermally treated to eliminate airlocks within the micropipette lumen and establish a liquid path between microbial challenge media and the test units' contents. Microbial challenge was performed by immersing the test units in a 35 degrees C bath containing magnesium ion and 8 to 10 logs of viable P. diminuta and E. coli for 24 hours. The test units were then incubated at 35 degrees C for an additional 13 days. Microbial ingress was detected by turbidity and plating on blood agar. The elimination of airlocks was confirmed by the presence of magnesium ions in the vial contents by atomic absorption spectrometry. A total of 288 vials were subjected to microbial challenge testing. Those test units whose contents failed to show detectable magnesium ions were eliminated from further analysis. At large leak rates, the probability of microbial ingress approached 100% and at very low leak rates microbial ingress rates were 0%. A dramatic increase in microbial failure occurred in the leak rate region 10(-4.5) to 10(-3) std cc/sec, which roughly corresponded to leak diameters ranging from 0.4 to 2 microns. Below a leak rate of 10(-4.5) std cc/sec the microbial failure rate was < 10%. The critical leak rate in our studies, i.e. the value below which microbial ingress cannot occur because the leak is too small, was observed to be between 10(-5) and 10(-5.8) std cc/sec, which corresponds to an approximate leak diameter of 0.2-0.3 micron.
Do you have a well-designed organization?
Goold, Michael; Campbell, Andrew
2002-03-01
For most companies, organization design is neither a science nor an art; it's an oxymoron. Organizational structures evolve in fits and starts, shaped more by politics than by policies. Although most executives can sense when their organization designs are not working well, few take meaningful action, partly because they lack a practical framework to guide them. The authors of this article provide just such a framework; they present nine tests that can be used to either evaluate an existing organization design or create a new one. Four "fit" tests offer an initial screen: The market advantage test asks whether a design directs sufficient management attention to the company's sources of competitive advantage; the parenting advantage test determines whether the design gives enough attention to the corporate-level activities that provide real value to the company; the people test shows whether the design reflects the employees' strengths; and the feasibility test looks at constraints that may impede implementation. Five "good design" tests can help a company refine its prospective design. The specialist cultures test ensures that there's sufficient insulation for units that need to be different from the prevailing culture; the difficult-links test determines whether a design offers solutions for potentially problematic unit-to-unit links; the redundant-hierarchy test asks whether the design has too many parent levels; the accountability test looks at whether every unit has suitable controls; and the flexibility test ensures that the design lets the company adapt to change. Once a design is altered, the tests should be repeated. Organizational decisions are inevitably complex, and tweaking one part of the design may produce unanticipated consequences elsewhere.
Determination of hydraulic properties in the vicinity of a landfill near Antioch, Illinois
Kay, Robert T.; Earle, John D.
1990-01-01
A hydrogeologic investigation was conducted in and around a landfill near Antioch, Illinois, in December 1987. The investigation consisted, in part, of an aquifer test that was designed to determine the hydraulic connection between the hydrogeologic units in the area. The hydrogeologic units consist of a shallow, unconfined, sand and gravel aquifer of variable thickness that overlies an intermediate confining unit of variable thickness composed predominantly of till. Underlying the till is a deep, confined, sand and gravel aquifer that serves as the water supply for the village of Antioch. The aquifer test was conducted in the confined aquifer. Aquifer-test data were analyzed using the Hantush and Jacob method for a leaky confined aquifer with no storage in the confining unit. Calculated transmissivity of the confined aquifer ranged from 1.96x10^4 to 2.52x10^4 foot squared per day and storativity ranged from 2.10x10^-4 to 8.71x10^-4. Leakage through the confining unit ranged from 1.29x10^-4 to 7.84x10^-4 foot per day per foot, and hydraulic conductivity of the confining unit ranged from 3.22x10^-3 to 1.96x10^-2 foot per day. The Hantush method for analysis of a leaky confined aquifer with storage in the confining unit also was used to estimate aquifer and confining-unit properties. Transmissivity and storativity values calculated using the Hantush method are in good agreement with the values calculated from the Hantush and Jacob method. Properties of the confining unit were estimated using the ratio method of Neuman and Witherspoon. The estimated diffusivity of the confining unit ranged from 50.36 to 68.13 feet squared per day, A value for the vertical hydraulic conductivity of the confining unit calculated from data obtained using both the Hantush and the Neuman and Witherspoon methods was within the range of values calculated by the Hantush and Jacob method. The aquifer-test data clearly showed that the confining unit is hydraulically connected to the confined aquifer. The aquifer-test data also indicated that the unconfined aquifer becomes hydraulically connected to the deep sand and gravel aquifer within 24 hours after the start of pumping in the confined aquifer.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the boiler at a normal or conservatively high excess oxygen level in conjunction with these tests....2Substitute 1.25 times the highest NOX emission rate from the baseline correlation tests for the fuel (or fuel... potential NOX emission rate (MER) (as defined in § 72.2 of this chapter) for each unit operating hour...
Code of Federal Regulations, 2012 CFR
2012-07-01
... the boiler at a normal or conservatively high excess oxygen level in conjunction with these tests....2Substitute 1.25 times the highest NOX emission rate from the baseline correlation tests for the fuel (or fuel... potential NOX emission rate (MER) (as defined in § 72.2 of this chapter) for each unit operating hour...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Inorganic HAP Emissions From Catalytic Reforming Units 25 Table 25 to Subpart UUU of Part 63 Protection of... Units Pt. 63, Subpt. UUU, Table 25 Table 25 to Subpart UUU of Part 63—Requirements for Performance Tests... Procedure) in appendix A to subpart UUU; or EPA Method 5050 combined either with EPA Method 9056, or with...
Estimating Missing Unit Process Data in Life Cycle Assessment Using a Similarity-Based Approach.
Hou, Ping; Cai, Jiarui; Qu, Shen; Xu, Ming
2018-05-01
In life cycle assessment (LCA), collecting unit process data from the empirical sources (i.e., meter readings, operation logs/journals) is often costly and time-consuming. We propose a new computational approach to estimate missing unit process data solely relying on limited known data based on a similarity-based link prediction method. The intuition is that similar processes in a unit process network tend to have similar material/energy inputs and waste/emission outputs. We use the ecoinvent 3.1 unit process data sets to test our method in four steps: (1) dividing the data sets into a training set and a test set; (2) randomly removing certain numbers of data in the test set indicated as missing; (3) using similarity-weighted means of various numbers of most similar processes in the training set to estimate the missing data in the test set; and (4) comparing estimated data with the original values to determine the performance of the estimation. The results show that missing data can be accurately estimated when less than 5% data are missing in one process. The estimation performance decreases as the percentage of missing data increases. This study provides a new approach to compile unit process data and demonstrates a promising potential of using computational approaches for LCA data compilation.
ERIC Educational Resources Information Center
Kouimanos, John, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Test Program for Assessing Vulnerability of Industrial Equipment to Nuclear Air Blast.
1983-10-01
PROJECT. TASK 4Scientific Servic, Inc. AREA & WORK UNIT NUMBERS 517 East Bayshore Work Unit 1124F Redwood City, CA 94063___ __________ 11. CONTROLLING ...vulnerability, but perhaps less expensive, to be selected and substituted, with an eye to cost control . 5. MODELING AND SCALING CONSIDERATIONS Reiterating...behavior and properties of the test items and Interfaces that control behavior (e4g., test objects/flow field, test objects/interfacing surface of
Vodnick, David James; Dwivedi, Arpit; Keranen, Lucas Paul; Okerlund, Michael David; Schmitz, Roger William; Warren, Oden Lee; Young, Christopher David
2014-07-08
An automated testing system includes systems and methods to facilitate inline production testing of samples at a micro (multiple microns) or less scale with a mechanical testing instrument. In an example, the system includes a probe changing assembly for coupling and decoupling a probe of the instrument. The probe changing assembly includes a probe change unit configured to grasp one of a plurality of probes in a probe magazine and couple one of the probes with an instrument probe receptacle. An actuator is coupled with the probe change unit, and the actuator is configured to move and align the probe change unit with the probe magazine and the instrument probe receptacle. In another example, the automated testing system includes a multiple degree of freedom stage for aligning a sample testing location with the instrument. The stage includes a sample stage and a stage actuator assembly including translational and rotational actuators.
Vodnick, David James; Dwivedi, Arpit; Keranen, Lucas Paul; Okerlund, Michael David; Schmitz, Roger William; Warren, Oden Lee; Young, Christopher David
2015-01-27
An automated testing system includes systems and methods to facilitate inline production testing of samples at a micro (multiple microns) or less scale with a mechanical testing instrument. In an example, the system includes a probe changing assembly for coupling and decoupling a probe of the instrument. The probe changing assembly includes a probe change unit configured to grasp one of a plurality of probes in a probe magazine and couple one of the probes with an instrument probe receptacle. An actuator is coupled with the probe change unit, and the actuator is configured to move and align the probe change unit with the probe magazine and the instrument probe receptacle. In another example, the automated testing system includes a multiple degree of freedom stage for aligning a sample testing location with the instrument. The stage includes a sample stage and a stage actuator assembly including translational and rotational actuators.
Vodnick, David James; Dwivedi, Arpit; Keranen, Lucas Paul; Okerlund, Michael David; Schmitz, Roger William; Warren, Oden Lee; Young, Christopher David
2015-02-24
An automated testing system includes systems and methods to facilitate inline production testing of samples at a micro (multiple microns) or less scale with a mechanical testing instrument. In an example, the system includes a probe changing assembly for coupling and decoupling a probe of the instrument. The probe changing assembly includes a probe change unit configured to grasp one of a plurality of probes in a probe magazine and couple one of the probes with an instrument probe receptacle. An actuator is coupled with the probe change unit, and the actuator is configured to move and align the probe change unit with the probe magazine and the instrument probe receptacle. In another example, the automated testing system includes a multiple degree of freedom stage for aligning a sample testing location with the instrument. The stage includes a sample stage and a stage actuator assembly including translational and rotational actuators.
Ground Operations Aerospace Language (GOAL). Volume 3: Data bank
NASA Technical Reports Server (NTRS)
1973-01-01
The GOAL (Ground Operations Aerospace Language) test programming language was developed for use in ground checkout operations in a space vehicle launch environment. To insure compatibility with a maximum number of applications, a systematic and error-free method of referencing command/response (analog and digital) hardware measurements is a principle feature of the language. Central to the concept of requiring the test language to be independent of launch complex equipment and terminology is that of addressing measurements via symbolic names that have meaning directly in the hardware units being tested. To form the link from test program through test system interfaces to the units being tested the concept of a data bank has been introduced. The data bank is actually a large cross-reference table that provides pertinent hardware data such as interface unit addresses, data bus routings, or any other system values required to locate and access measurements.
Tests of an experimental slash ignition unit
James L. Murphy; Harry E. Schimke
1965-01-01
A prototype ignition package containing an incendiary powder and designed for slash and brush burning jobs showed some promise, but the unit tested was not superior to such conventional devices as fusees, diesel backpack type flamethrowers, Very pistols, and drip torches.
ERIC Educational Resources Information Center
Cowan, Earl; And Others
The curriculum guide for welding instruction contains 16 units presented in six sections. Each unit is divided into the following areas, each of which is color coded: terminal objectives, specific objectives, suggested activities, and instructional materials; information sheet; transparency masters; assignment sheet; test; and test answers. The…
Butler, T J; Kilbreath, S L; Gorman, R B; Gandevia, S C
2005-08-15
Flexor digitorum superficialis (FDS) is an extrinsic multi-tendoned muscle which flexes the proximal interphalangeal joints of the four fingers. It comprises four digital components, each with a tendon that inserts onto its corresponding finger. To determine the degree to which these digital components can be selectively recruited by volition, we recorded the activity of a single motor unit in one component via an intramuscular electrode while the subject isometrically flexed each of the remaining fingers, one at a time. The finger on which the unit principally acted was defined as the 'test finger' and that which flexed isometrically was the 'active' finger. Activity in 79 units was recorded. Isometric finger flexion forces of 50% maximum voluntary contraction (MVC) activated less than 50% of single units in components of FDS acting on fingers that were not voluntarily flexed. With two exceptions, the median recruitment threshold for all active-test finger combinations involving the index, middle, ring and little finger test units was between 49 and 60% MVC (60% MVC being the value assigned to those not recruited). The exceptions were flexion of the little finger while recording from ring finger units (median: 40% MVC), and vice versa (median: 2% MVC). For all active-test finger combinations, only 35/181 units were activated when the active finger flexed at less than 20% MVC, and the fingers were adjacent for 28 of these. Functionally, to recruit FDS units during grasping and lifting, relatively heavy objects were required, although systematic variation occurred with the width of the object. In conclusion, FDS components can be selectively activated by volition and this may be especially important for grasping at high forces with one or more fingers.
46 CFR 131.585 - Periodic servicing of hydrostatic-release units.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Periodic servicing of hydrostatic-release units. 131.585... OPERATIONS Tests, Drills, and Inspections § 131.585 Periodic servicing of hydrostatic-release units. (a) Except a disposable hydrostatic-release unit with an expiration date, each hydrostatic-release unit must...
49 CFR 234.217 - Flashing light units.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Flashing light units. 234.217 Section 234.217..., Inspection, and Testing Maintenance Standards § 234.217 Flashing light units. (a) Each flashing light unit.... (b) Each flashing light unit shall be maintained to prevent dust and moisture from entering the...
49 CFR 234.217 - Flashing light units.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Flashing light units. 234.217 Section 234.217..., Inspection, and Testing Maintenance Standards § 234.217 Flashing light units. (a) Each flashing light unit.... (b) Each flashing light unit shall be maintained to prevent dust and moisture from entering the...
Garcia, C. Amanda; Halford, Keith J.; Laczniak, Randell J.
2010-01-01
Hydraulic conductivities of volcanic and carbonate lithologic units at the Nevada Test Site were estimated from flow logs and aquifer-test data. Borehole flow and drawdown were integrated and interpreted using a radial, axisymmetric flow model, AnalyzeHOLE. This integrated approach is used because complex well completions and heterogeneous aquifers and confining units produce vertical flow in the annular space and aquifers adjacent to the wellbore. AnalyzeHOLE simulates vertical flow, in addition to horizontal flow, which accounts for converging flow toward screen ends and diverging flow toward transmissive intervals. Simulated aquifers and confining units uniformly are subdivided by depth into intervals in which the hydraulic conductivity is estimated with the Parameter ESTimation (PEST) software. Between 50 and 150 hydraulic-conductivity parameters were estimated by minimizing weighted differences between simulated and measured flow and drawdown. Transmissivity estimates from single-well or multiple-well aquifer tests were used to constrain estimates of hydraulic conductivity. The distribution of hydraulic conductivity within each lithology had a minimum variance because estimates were constrained with Tikhonov regularization. AnalyzeHOLE simulated hydraulic-conductivity estimates for lithologic units across screened and cased intervals are as much as 100 times less than those estimated using proportional flow-log analyses applied across screened intervals only. Smaller estimates of hydraulic conductivity for individual lithologic units are simulated because sections of the unit behind cased intervals of the wellbore are not assumed to be impermeable, and therefore, can contribute flow to the wellbore. Simulated hydraulic-conductivity estimates vary by more than three orders of magnitude across a lithologic unit, indicating a high degree of heterogeneity in volcanic and carbonate-rock units. The higher water transmitting potential of carbonate-rock units relative to volcanic-rock units is exemplified by the large difference in their estimated maximum hydraulic conductivity; 4,000 and 400 feet per day, respectively. Simulated minimum estimates of hydraulic conductivity are inexact and represent the lower detection limit of the method. Minimum thicknesses of lithologic intervals also were defined for comparing AnalyzeHOLE results to hydraulic properties in regional ground-water flow models.
Development Studies for a Novel Wet Oxidation Process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Delphi Research
1999-09-30
DETOX is a catalyzed wet oxidation process that destroys organic materials in an acidic water solution of iron at 373 to 473 K. The solution can be used repeatedly to destroy great amounts of organic materials. Since the process is conducted in a contained vessel, air emissions from the process can be well controlled. The solution is also capable of dissolving and concentrating many heavy and radioactive metals for eventual stabilization and disposal. The Phase III effort for this project is fabrication, assembly, and installation of the DETOX demonstration unit, preparation of documentation and training to meet site requirements formore » operation, followed by system run-in and shakedown testing of the unit prior to demonstration testing. The Title III design was completed and the unit was fabricated according to standards set forth by OSHA, EPA, the American Petroleum Institute (i.e., chemical and petroleum industry standards), and the ASME B-313 Piping Code requirements as agreed to in preliminary design meetings with primary stakeholders. The unit was assembled in three modules and two trailers and then shipped to the TNX facility at the Savannah River Site in September and october of 1996. On-going site integration tasks were address while delays in installation arose due to funding sources and costs. In March of 1997, Delphi was authorized to proceed with the installation of the unit, making electrical and mechanical connections necessary to operate the unit. All installation tasks were completed in August of 1997. Results of an Operational Readiness Review conducted in August 1997 verified that Delphi's procedures and documentation met the necessary requirements to operate the unit at SRS. Completion of the final checklist of WSRC requirements was then addressed including the Owner's Independent Inspection Report, verifying all components of the unit met B-31.3 standards. Final hydraulic and pneumatic tests were completed in November to satisfy the B-31.3 requirement. During the month of December, the control system and heating and cooling systems were then prepared to initiate system startup and conduct the run-in tests. Shakedown tests were combined with the Phase IV tasks due to DOE funding constraints, i.e., tests formerly planned to be conducted with oil and solid materials were deferred to Phase IV and combined with similar testing. Once run-in testing has been completed, the primary objectives of Phase III will have been achieved and the project will be ready to proceed to demonstration testing (Phase IV).« less
Integrity verification testing of the ADI International Inc. Pilot Test Unit No. 2002-09 with MEDIA G2® arsenic adsorption media filter system was conducted at the Hilltown Township Water and Sewer Authority (HTWSA) Well Station No. 1 in Sellersville, Pennsylvania from October 8...
United States nuclear tests, July 1945 through September 1992
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-12-01
This document lists chronologically and alphabetically by name all nuclear tests and simultaneous detonations conducted by the United States from July 1945 through September 1992. Several tests conducted during Operation Dominic involved missile launches from Johnston Atoll. Several of these missile launches were aborted, resulting in the destruction of the missile and nuclear device either on the pad or in the air.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bechtel Nevada; U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office
2005-05-01
This Streamlined Approach for Environmental Restoration Plan provides the details for the closure of Corrective Action Unit (CAU) 489: WWII UXO Sites, Tonopah Test Range. CAU 489 is located at the Tonopah Test Range and is currently listed in Appendix III of the Federal Facility Agreement and Consent Order of 1996.
Motor unit behaviour and contractile changes during fatigue in the human first dorsal interosseus
Carpentier, Alain; Duchateau, Jacques; Hainaut, Karl
2001-01-01
In 67 single motor units, the mechanical properties, the recruitment and derecruitment thresholds, and the discharge rates were recorded concurrently in the first dorsal interosseus (FDI) of human subjects during intermittent fatiguing contractions. The task consisted of isometric ramp-and-hold contractions performed at 50% of the maximal voluntary contraction (MVC). The purpose of this study was to examine the influence of fatigue on the behaviour of motor units with a wide range of activation thresholds. For low-threshold (< 25% MVC) motor units, the mean twitch force increased with fatigue and the recruitment threshold either did not change or increased. In contrast, the twitch force and the activation threshold decreased for the high-threshold (> 25% MVC) units. The observation that in low-threshold motor units a quick stretch of the muscle at the end of the test reset the unit force and recruitment threshold to the prefatigue value suggests a significant role for fatigue-related changes in muscle stiffness but not twitch potentiation or motor unit synchronization. Although the central drive intensified during the fatigue test, as indicated by an increase in surface electromyogram (EMG), the discharge rate of the motor units during the hold phase of each contraction decreased progressively over the course of the task for motor units that were recruited at the beginning of the test, especially the low-threshold units. In contrast, the discharge rates of newly activated units first increased and then decreased. Such divergent behaviour of low- and high-threshold motor units could not be individually controlled by the central drive to the motoneurone pool. Rather, the different behaviours must be the consequence of variable contributions from motoneurone adaptation and afferent feedback from the muscle during the fatiguing contraction. PMID:11483719
The 1991 LLWAS anemometer test program
NASA Astrophysics Data System (ADS)
Phillips, Charles O.; Burnham, David; Jacobs, Leo; Hazen, David
1992-09-01
Performance tests of anemometers under icing and snow conditions were conducted during 1990-1991 on the test field at Rochester, MN and in icing chambers and wind tunnels at Sterling, VA. These tests were done for the FAA Low Level Windshear Alert System (LLWAS) program to test sensors for the next phase of LLWAS. Sensors from ten manufacturers were accepted into the test program from the respondents to the Commerce Business Daily. These sensors were required first to pass an icing chamber test in order to be field tested. The field tests lasted from Nov. 1990 to Jul. 1991. Afterwards, all sensors were sent to Sterling, VA for wind tunnel tests in September 1991. All units from the eight manufacturers that passed the icing chamber test were in the field test. A propeller/vane sensor that failed the icing chamber test was put in the field as a reference. All the units that passed were not affected by icing during the field test although a mechanical unit was affected by snow during one event. The propeller/vane was affected by icing during one event. Wind tunnel tests were done to check starting thresholds and calibration anomalies found in the field. It was concluded that there is no one winning technology that could be found from the tests.
NASA Technical Reports Server (NTRS)
Wilson, D. J.; Krause, M. C.; Craven, C. E.; Edwards, B. B.; Coffey, E. W.; Huang, C. C.; Jetton, J. L.; Morrison, L. K.
1974-01-01
A program plan for system evaluation of the two-dimensional Scanning Laser Doppler System (SLDS) is presented. In order to meet system evaluation and optimization objectives the following tests were conducted: (1) noise tests; (2) wind tests; (3) blower flowfield tests; (4) single unit (1-D) flyby tests; and (5) dual unit (2-D) flyby tests. Test results are reported. The final phase of the program included logistics preparation, equipment interface checkouts, and data processing. It is concluded that the SLDS is capable of accurately tracking aircraft wake vortices from small or large aircraft, and in any type of weather.
Turbine Powered Simulator Calibration and Testing for Hybrid Wing Body Powered Airframe Integration
NASA Technical Reports Server (NTRS)
Shea, Patrick R.; Flamm, Jeffrey D.; Long, Kurtis R.; James, Kevin D.; Tompkins, Daniel M.; Beyar, Michael D.
2016-01-01
Propulsion airframe integration testing on a 5.75% scale hybrid wing body model us- ing turbine powered simulators was completed at the National Full-Scale Aerodynamics Complex 40- by 80-foot test section. Four rear control surface con gurations including a no control surface de ection con guration were tested with the turbine powered simulator units to investigate how the jet exhaust in uenced the control surface performance as re- lated to the resultant forces and moments on the model. Compared to ow-through nacelle testing on the same hybrid wing body model, the control surface e ectiveness was found to increase with the turbine powered simulator units operating. This was true for pitching moment, lift, and drag although pitching moment was the parameter of greatest interest for this project. With the turbine powered simulator units operating, the model pitching moment was seen to increase when compared to the ow-through nacelle con guration indicating that the center elevon and vertical tail control authority increased with the jet exhaust from the turbine powered simulator units.
Statistical modeling of dental unit water bacterial test kit performance.
Cohen, Mark E; Harte, Jennifer A; Stone, Mark E; O'Connor, Karen H; Coen, Michael L; Cullum, Malford E
2007-01-01
While it is important to monitor dental water quality, it is unclear whether in-office test kits provide bacterial counts comparable to the gold standard method (R2A). Studies were conducted on specimens with known bacterial concentrations, and from dental units, to evaluate test kit accuracy across a range of bacterial types and loads. Colony forming units (CFU) were counted for samples from each source, using R2A and two types of test kits, and conformity to Poisson distribution expectations was evaluated. Poisson regression was used to test for effects of source and device, and to estimate rate ratios for kits relative to R2A. For all devices, distributions were Poisson for low CFU/mL when only beige-pigmented bacteria were considered. For higher counts, R2A remained Poisson, but kits exhibited over-dispersion. Both kits undercounted relative to R2A, but the degree of undercounting was reasonably stable. Kits did not grow pink-pigmented bacteria from dental-unit water identified as Methylobacterium rhodesianum. Only one of the test kits provided results with adequate reliability at higher bacterial concentrations. Undercount bias could be estimated for this device and used to adjust test kit results. Insensitivity to methylobacteria spp. is problematic.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baxter, V. D.; Rice, K.; Murphy, R.
Between October 2008 and May 2013 ORNL and ClimateMaster, Inc. (CM) engaged in a Cooperative Research and Development Agreement (CRADA) to develop a groundsource integrated heat pump (GS-IHP) system for the US residential market. A initial prototype was designed and fabricated, lab-tested, and modeled in TRNSYS (SOLAR Energy Laboratory, et al, 2010) to predict annual performance relative to 1) a baseline suite of equipment meeting minimum efficiency standards in effect in 2006 (combination of air-source heat pump (ASHP) and resistance water heater) and 2) a state-of-the-art (SOA) two-capacity ground-source heat pump with desuperheater water heater (WH) option (GSHPwDS). Predicted totalmore » annual energy savings, while providing space conditioning and water heating for a 2600 ft{sup 2} (242 m{sup 2}) house at 5 U.S. locations, ranged from 52 to 59%, averaging 55%, relative to the minimum efficiency suite. Predicted energy use for water heating was reduced 68 to 78% relative to resistance WH. Predicted total annual savings for the GSHPwDS relative to the same baseline averaged 22.6% with water heating energy use reduced by 10 to 30% from desuperheater contributions. The 1st generation (or alpha) prototype design for the GS-IHP was finalized in 2010 and field test samples were fabricated for testing by CM and by ORNL. Two of the alpha units were installed in 3700 ft{sup 2} (345 m{sup 2}) houses at the ZEBRAlliance site in Oak Ridge and field tested during 2011. Based on the steady-state performance demonstrated by the GS-IHPs it was projected that it would achieve >52% energy savings relative to the minimum efficiency suite at this specific site. A number of operational issues with the alpha units were identified indicating design changes needed to the system before market introduction could be accomplished. These were communicated to CM throughout the field test period. Based on the alpha unit test results and the diagnostic information coming from the field test experience, CM developed a 2nd generation (or beta) prototype in 2012. Field test verification units were fabricated and installed at the ZEBRAlliance site in Oak Ridge in May 2012 and at several sites near CM headquarters in Oklahoma. Field testing of the units continued through February 2013. Annual performance analyses of the beta unit (prototype 2) with vertical well ground heat exchangers (GHX) in 5 U.S. locations predict annual energy savings of 57% to 61%, averaging 59% relative to the minimum efficiency suite and 38% to 56%, averaging 46% relative to the SOA GSHPwDS. Based on the steady-state performance demonstrated by the test units it was projected that the 2nd generation units would achieve ~58% energy savings relative to the minimum efficiency suite at the Zebra Alliance site with horizontal GHX. A new product based on the beta unit design was announced by CM in 2012 – the Trilogy 40® Q-mode™ (http://cmdealernet.com/trilogy_40.html). The unit was formally introduced in a March 2012 press release (see Appendix A) and was available for order beginning in December 2012.« less
Qualification test unit slide stainer (Beckman P/N 673753)
NASA Technical Reports Server (NTRS)
Bernier, P. S.
1972-01-01
Specifications for a slide stainer unit for the Skylab program are presented. The qualification test slide stainer was designed to be a self-contained system capable of performing an eight-step Gram stain of microorganisms and a Wright's stain of blood smears.
Basic Facialist. Teacher Edition. Cosmetology Series.
ERIC Educational Resources Information Center
Rogers, Jeanette A.
This Oklahoma curriculum guide contains six units. Each instructional unit includes some or all of these basic components: performance objectives; suggested activities for the teacher; pretest; handouts; information sheets; transparency masters; assignment sheets; job sheets; practical tests; written tests; and answers to pretest, assignment…
Code of Federal Regulations, 2011 CFR
2011-07-01
... distributed across the specific number of units. The nonrecurring research, development, test, and evaluation... significant military equipment on the United States Munitions List having a nonrecurring research, development... for research, development, test, and evaluation shall be based on DoD obligations recorded to the date...
Test Results from a Direct Drive Gas Reactor Simulator Coupled to a Brayton Power Conversion Unit
NASA Technical Reports Server (NTRS)
Hervol, David S.; Briggs, Maxwell H.; Owen, Albert K.; Bragg-Sitton, Shannon M.; Godfroy, Thomas J.
2010-01-01
Component level testing of power conversion units proposed for use in fission surface power systems has typically been done using relatively simple electric heaters for thermal input. These heaters do not adequately represent the geometry or response of proposed reactors. As testing of fission surface power systems transitions from the component level to the system level it becomes necessary to more accurately replicate these reactors using reactor simulators. The Direct Drive Gas-Brayton Power Conversion Unit test activity at the NASA Glenn Research Center integrates a reactor simulator with an existing Brayton test rig. The response of the reactor simulator to a change in Brayton shaft speed is shown as well as the response of the Brayton to an insertion of reactivity, corresponding to a drum reconfiguration. The lessons learned from these tests can be used to improve the design of future reactor simulators which can be used in system level fission surface power tests.
Moore, Andrew; Nelson, Christina; Molins, Claudia; Mead, Paul
2016-01-01
In the United States, Lyme disease is caused by Borrelia burgdorferi and transmitted to humans by blacklegged ticks. Patients with an erythema migrans lesion and epidemiologic risk can receive a diagnosis without laboratory testing. For all other patients, laboratory testing is necessary to confirm the diagnosis, but proper interpretation depends on symptoms and timing of illness. The recommended laboratory test in the United States is 2-tiered serologic analysis consisting of an enzyme-linked immunoassay or immunofluorescence assay, followed by reflexive immunoblotting. Sensitivity of 2-tiered testing is low (30%–40%) during early infection while the antibody response is developing (window period). For disseminated Lyme disease, sensitivity is 70%–100%. Specificity is high (>95%) during all stages of disease. Use of other diagnostic tests for Lyme disease is limited. We review the rationale behind current US testing guidelines, appropriate use and interpretation of tests, and recent developments in Lyme disease diagnostics. PMID:27314832
Simon, Uwe K.; Gesslbauer, Lisa; Fink, Andreas
2016-01-01
Epilepsy is not a regular topic in many countries’ schools. Thus many people harbor misconceptions about people suffering from this disease. It was our aim to a) examine what grade ten students know and believe about epilepsy, and b) to develop and test a teaching unit to improve their knowledge and attitude. The test group comprised eight grade ten classes from six different Austrian high schools (54 girls and 51 boys aged 14–17), the control group (no intervention) five grade ten classes from the same schools (26 girls and 37 boys aged 14–17). The teaching unit consisted of three 45-min lessons using different methods and material. Changes in knowledge about and attitude towards epilepsy as a result of the intervention were psychometrically assessed in a pre-test intervention post-test design (along with a follow-up assessment two months after the intervention) by means of a questionnaire capturing different facets of epilepsy-related knowledge and attitude. Across all knowledge/attitude domains, students of the test group had a significantly improved knowledge about and a more positive attitude towards epilepsy and people suffering from it after the teaching unit. However, starting levels were different between the five knowledge/attitude domains tested. Medical background knowledge was lowest and consequently associated with the highest increase after the intervention. This study shows that epilepsy-related knowledge of many grade ten high school students is fragmentary and that some harbor beliefs and attitudes which require improvement. Our comprehensive but concise teaching unit significantly increased knowledge about epilepsy and positively influenced attitude towards individuals with epilepsy. Thus we recommend implementing this unit into regular school curricula. PMID:26919557
Daniels, Alan H; Paller, David J; Koruprolu, Sarath; Palumbo, Mark A; Crisco, Joseph J
2013-01-01
Biomechanical investigations of spinal motion preserving implants help in the understanding of their in vivo behavior. In this study, we hypothesized that the lumbar spine with implanted total spinal segment replacement (TSSR) would exhibit decreased dynamic stiffness and more rapid energy absorption compared to native functional spinal units under simulated physiologic motion when tested with the pendulum system. Five unembalmed, frozen human lumbar functional spinal units were tested on the pendulum system with axial compressive loads of 181 N, 282 N, 385 N, and 488 N before and after Flexuspine total spinal segment replacement implantation. Testing in flexion, extension, and lateral bending began by rotating the pendulum to 5°; resulting in unconstrained oscillatory motion. The number of rotations to equilibrium was recorded and bending stiffness (N-m/°) was calculated and compared for each testing mode. The total spinal segment replacement reached equilibrium with significantly fewer cycles to equilibrium compared to the intact functional spinal unit at all loads in flexion (p<0.011), and at loads of 385 N and 488 N in lateral bending (p<0.020). Mean bending stiffness in flexion, extension, and lateral bending increased with increasing load for both the intact functional spinal unit and total spinal segment replacement constructs (p<0.001), with no significant differences in stiffness between the intact functional spinal unit and total spinal segment replacement in any of the test modes (p>0.18). Lumbar functional spinal units with implanted total spinal segment replacement were found to have similar dynamic bending stiffness, but absorbed energy at a more rapid rate than intact functional spinal units during cyclic loading with an unconstrained pendulum system. Although the effects on clinical performance of motion preserving devices is not fully known, these results provide further insight into the biomechanical behavior of this device under approximated physiologic loading conditions.
Daniels, Alan H.; Paller, David J.; Koruprolu, Sarath; Palumbo, Mark A.; Crisco, Joseph J.
2013-01-01
Background Biomechanical investigations of spinal motion preserving implants help in the understanding of their in vivo behavior. In this study, we hypothesized that the lumbar spine with implanted total spinal segment replacement (TSSR) would exhibit decreased dynamic stiffness and more rapid energy absorption compared to native functional spinal units under simulated physiologic motion when tested with the pendulum system. Methods Five unembalmed, frozen human lumbar functional spinal units were tested on the pendulum system with axial compressive loads of 181 N, 282 N, 385 N, and 488 N before and after Flexuspine total spinal segment replacement implantation. Testing in flexion, extension, and lateral bending began by rotating the pendulum to 5°; resulting in unconstrained oscillatory motion. The number of rotations to equilibrium was recorded and bending stiffness (N-m/°) was calculated and compared for each testing mode. Results The total spinal segment replacement reached equilibrium with significantly fewer cycles to equilibrium compared to the intact functional spinal unit at all loads in flexion (p<0.011), and at loads of 385 N and 488 N in lateral bending (p<0.020). Mean bending stiffness in flexion, extension, and lateral bending increased with increasing load for both the intact functional spinal unit and total spinal segment replacement constructs (p<0.001), with no significant differences in stiffness between the intact functional spinal unit and total spinal segment replacement in any of the test modes (p>0.18). Conclusions Lumbar functional spinal units with implanted total spinal segment replacement were found to have similar dynamic bending stiffness, but absorbed energy at a more rapid rate than intact functional spinal units during cyclic loading with an unconstrained pendulum system. Although the effects on clinical performance of motion preserving devices is not fully known, these results provide further insight into the biomechanical behavior of this device under approximated physiologic loading conditions. PMID:23451222
Saturn V Instrument Unit Being Checked At MSFC
NASA Technical Reports Server (NTRS)
1967-01-01
A technician checks the systems of the Saturn V instrument unit in a test facility in Huntsville. This instrument unit was flown aboard Apollo 4 on November 7, 1967, which was the first test flight of the Saturn V. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.
Absolute pressure transducers for space shuttle and orbiter propulsion and control systems
NASA Technical Reports Server (NTRS)
Bolta, J. J.
1974-01-01
A preliminary design was completed, reviewing of such subjects as: the trade studies for media isolation and one sensor vs. two sensors for two bridges; compensation resistors; unit design; hydrogen embrittlement; sealing techniques and test station design. A design substantiation phase was finished, consisting of testing of a prototype unit and fabrication technique studies. A cryogenic test station was implemented and prototype sensor cells were fabricated, sensors assembled, and cryogenic tests performed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sivakumar Babu, G.L., E-mail: gls@civil.iisc.ernet.in; Lakshmikanthan, P., E-mail: lakshmikanthancp@gmail.com; Santhosh, L.G., E-mail: lgsanthu2006@gmail.com
Highlights: • Shear strength properties of mechanically biologically treated municipal solid waste. • Effect of unit weight and particle size on the shear strength of waste. • Effect of particle size on the strength properties. • Stiffness ratio and the strength ratio of MSW. - Abstract: Strength and stiffness properties of municipal solid waste (MSW) are important in landfill design. This paper presents the results of comprehensive testing of shear strength properties of mechanically biologically treated municipal solid waste (MBT-MSW) in laboratory. Changes in shear strength of MSW as a function of unit weight and particle size were investigated bymore » performing laboratory studies on the MSW collected from Mavallipura landfill site in Bangalore. Direct shear tests, small scale and large scale consolidated undrained and drained triaxial tests were conducted on reconstituted compost reject MSW samples. The triaxial test results showed that the MSW samples exhibited a strain-hardening behaviour and the strength of MSW increased with increase in unit weight. Consolidated drained tests showed that the mobilized shear strength of the MSW increased by 40% for a unit weight increase from 7.3 kN/m{sup 3} to 10.3 kN/m{sup 3} at 20% strain levels. The mobilized cohesion and friction angle ranged from 5 to 9 kPa and 8° to 33° corresponding to a strain level of 20%. The consolidated undrained tests exhibited reduced friction angle values compared to the consolidated drained tests. The friction angle increased with increase in the unit weight from 8° to 55° in the consolidated undrained tests. Minor variations were found in the cohesion values. Relationships for strength and stiffness of MSW in terms of strength and stiffness ratios are developed and discussed. The stiffness ratio and the strength ratio of MSW were found to be 10 and 0.43.« less
NASA Astrophysics Data System (ADS)
Rustam, Shahrulfadly; Kassim, Mohar
2018-05-01
The aim of this study is to develop physical fitness index (PFI) for physical fitness among Army Reserve Officer Training Unit Cadet Malaysia. This study use 30 meter speed run as a physical fitness test battery to develop physical fitness index (PFI) and to evaluate the subject fitness speed. 212 male respondent (N=212) was selected in this study including Army Reserve Officer Training Unit Cadet of National Defence University of Malaysia. 30 meter sprint was used as a instrument for this study. The methodology will be adopted for this study is quantitative research in the form of a quasi-experiment. Quasi-experimental methods is used to measure and evaluate the level of physical fitness and develop Physical Fitness Index especially in speed. The design of this study is quasi-experimental study design with pre-test and post-test. The study design is quasi-experimental research design in which the data is obtained through the practical test in the field. The data were analysed by using the SPSS software version 20 to calculate the mean, standard deviation and t-test for develop physical fitness index (PFI) and to evaluate the fitness speed level for Army Reserve Officers Training Unit Cadet Malaysia. The findings showed mean and standard deviation for develope physical fitness index is (M=4.84) and (SD=0.48). The t-test for evaluate fitness level in speed for pre-test and post-test is significantly difference (p ≤ 0.05). The implication at this study is that the develope of standard physical fitness index is able to identify the level of physical fitness among Army Reserve Officer Training Unit Cadet Malaysia.
MTR WING, TRA604. ONE OF THE LABORATORY UNITS ALONG THE ...
MTR WING, TRA-604. ONE OF THE LABORATORY UNITS ALONG THE SOUTH SIDE WALL. NOTE SINK, CABINET, TABLE, AND HOOD UNITS. DUCT ABOVE RECEIVES CONTAMINATED AIR AND SENDS IT TO FAN HOUSE AND STACK. NOTE PARTITION WALL BEHIND WORK UNITS. THE HEALTH PHYSICS LAB WAS SIMILARLY EQUIPPED. WINDOW AT LEFT EDGE OF VIEW. CARD IN LOWER RIGHT WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION PRINTED ON ORIGINAL NEGATIVE. INL NEGATIVE NO. 4225. Unknown Photographer, 2/13/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Dunbar, Nancy M; Kreuter, Justin D; Marx-Wood, Cynthia R; Dumont, Larry J; Szczepiorkowski, Zbigniew M
2013-10-01
The platelet (PLT) Pan Genera Detection test (PGD) is a rapid bacterial detection system used to screen PLTs for bacterial contamination. We report a single center 46-month experience with secondary screening of apheresis PLTs by PGD testing. Existing testing records of apheresis PLTs screened by PGD from July 2008 to April 2012 were reviewed. All PLT units were initially screened by routine postcollection culture methods. Secondary screening using PGD was performed for indated PLTs on PLT storage Day 4 and for outdated PLTs on Day 8. A total of 8535 apheresis PLTs were available in inventory during the study period. Of these, 5030 (58.9%) were dispensed and transfused before PGD testing and 3505 (41.1%) underwent PGD testing on Day 4. Twenty-five units tested on Day 4 were PGD initial reactive (0.71%). All were confirmed to be false positive by repeat PGD testing in triplicate (n=20) or by confirmatory culture (n=5). An additional 364 units that were PGD nonreactive on Day 4 were approved for transfusion on Day 6 or Day 7 due to urgent clinical need. A total of 371 outdated units underwent repeat PGD testing before discard on Day 8; all were nonreactive. Secondary PGD testing of culture-screened apheresis PLTs results in low yield in a medium-sized transfusion service. Use of PGD testing on Day 4 may allow for extension of the apheresis PLT shelf life to Day 7 for hospitals that face supply constraints. © 2013 American Association of Blood Banks.
Design and performance of the VLT 8-m coating unit
NASA Astrophysics Data System (ADS)
Schneermann, Michael W.; Groessl, M.; Nienaber, U.; Ettlinger, E.; Spiteri, J. A.; Clow, H.
1997-03-01
The 8 m coating unit for the VLT mirrors is designed for the deposition of high reflective, homogeneous aluminum coatings. For the process of the film deposition the sputter technology is utilized. The design of the following major subsystems is completed: the vacuum vessel and the vacuum generation system, the thin film deposition equipment and the glow discharge cleaning device, the substrate support and rotation system as well as the supporting framework and the auxiliary equipment. Manufacturing of the coating unit has started. The pre- assembly and testing activities, which will take place prior to the shipment to the site, are defined. This paper describes the design features and the major performance requirements of the 8 m coating unit. The performance of the sputter source design has been verified in a qualification test. The deposition rate, the film thickness and reflectance, as well as the film purity have been measured. The test set-up and the results of the qualification tests of the selected magnetron type are presented and discussed.
Zhang, Quanguo; Zhang, Zhiping; Wang, Yi; Lee, Duu-Jong; Li, Gang; Zhou, Xuehua; Jiang, Danping; Xu, Bo; Lu, Chaoyang; Li, Yameng; Ge, Xumeng
2018-04-01
Pilot tests of sequential dark and photo fermentation H 2 production were for the first time conducted in a 11 m 3 reactor (3 m 3 for dark and 8 m 3 for photo compartments). A combined solar and light-emitting diode illumination system and a thermal controlling system was installed and tested. With dark fermentation unit maintained at pH 4.5 and 35 °C and photo fermentation unit at pH 7.0 and 30 °C, the overall biogas production rate using hydrolyzed corn stover as substrate reached 87.8 ± 3.8 m 3 /d with 68% H 2 content, contributed by dark unit at 7.5 m 3 -H 2 /m 3 -d and by photo unit at 4.7 m 3 /m 3 -d. Large variation was noted for H 2 production rate in different compartments of the tested units, revealing the adverse effects of poor mixing, washout, and other inhomogeneity associated with large reactor operations. Copyright © 2018 Elsevier Ltd. All rights reserved.
Use of the Blind Learning Aptitude Test with Children in England and Wales and the United States.
ERIC Educational Resources Information Center
Mason, H. L.
1991-01-01
An 18-month study of the use of the Blind Learning Aptitude Test at schools for visually impaired children in England and Wales found the test to be culturally fair and appropriate for use with children for whom English is a second language. Scores are compared with standardization data for visually impaired children in the United States.…
ERIC Educational Resources Information Center
Liu, Xiufeng; Zhang, Baohui; Liang, Ling L.; Fulmer, Gavin; Kim, Beaumie; Yuan, Haiquan
2009-01-01
Alignment between content standards and standardized tests is a significant issue to society, science pedagogy, and test validation. To better understand the issues related to alignment, this study compares the alignment in physics among three education systems: Jiangsu (China), New York State (United States), and Singapore. The same coding…
Use of technology as an evaluation tool of clinical care in preterm newborns.
Mendes, Izabel; Carvalho, Manoel de; Almeida, Rosimary Terezinha; Moreira, Maria Elizabeth
2006-01-01
To assess the use of the Neonatal Therapeutic Intervention Scoring System (NTISS) as a tool to quantify the use of technology in neonatal intensive care units, in order to detect discrepancies in the care provided to high-risk newborn infants. Prospective, descriptive, observational study about the use of technology in two neonatal intensive care units (one public and one private). The NTISS was calculated on a daily basis up to the discharge or death of preterm newborns with gestational age equal to or less than 32 weeks. We gathered data about prenatal clinical conditions, birth characteristics, and conditions on admission to the intensive care unit, as well as about the morbidities developed during the hospital stay. The risks of preterm newborns were adjusted by means of the Score for Neonatal Acute Physiology, Perinatal Extension, Version II (SNAPPE-II). Student's t test, chi-square test, Fisher's exact test, and the Mann-Whitney/Wilcoxon's test were used for the descriptive analysis. The study was approved by the local Research and Ethics Committee. We assessed 44 newborn infants from the public intensive care unit and 52 from the private one. On admission, the severity score (SNAPPE-II) and the overall NTISS were statistically similar in both care units. The curve for the use of technology showed a gradual and progressive decreasing pattern in both care units up to the 31st day. Thereafter, there was a continuous downward trend in the private care unit, but a significant increase in the overall NTISS in the public care unit. The patients from the public care unit developed more morbidities than those from the private unit. Patients with similar clinical pictures can be treated with different levels of technological resources. This may have a direct impact on morbidities and on healthcare costs. The NTISS allowed monitoring healthcare and proved efficient in detecting discrepancies in practices that could influence clinical outcomes and operating costs.
Nikolaidis, Pantelis T; Clemente, Filipe M; van der Linden, Cornelis M I; Rosemann, Thomas; Knechtle, Beat
2018-01-01
The objectives of the present study were to examine the validity and reliability of the 10 Hz Johan GPS unit in assessing in-line movement and change of direction. The validity was tested against the criterion measure of 200 m track-and-field (track-and-field athletes, n = 8) and 20 m shuttle run endurance test (female soccer players, n = 20). Intra-unit and inter-unit reliability was tested by intra-class correlation coefficient (ICC) and coefficient of variation (CV), respectively. An analysis of variance examined differences between the GPS measurement and five laps of 200 m at 15 km/h, and t -test examined differences between the GPS measurement and 20 m shuttle run endurance test. The difference between the GPS measurement and 200 m distance ranged from -0.13 ± 3.94 m (95% CI -3.42; 3.17) in the first lap to 2.13 ± 2.64 m (95% CI -0.08; 4.33) in the fifth lap. A good intra-unit reliability was observed in 200 m (ICC = 0.833, 95% CI 0.535; 0.962). Inter-unit CV ranged from 1.31% (fifth lap) to 2.20% (third lap). The difference between the GPS measurement and 20 m shuttle run endurance test ranged from 0.33 ± 4.16 m (95% CI -10.01; 10.68) in 11.5 km/h to 9.00 ± 5.30 m (95% CI 6.44; 11.56) in 8.0 km/h. A moderate intra-unit reliability was shown in the second and third stage of the 20 m shuttle run endurance test (ICC = 0.718, 95% CI 0.222;0.898) and good reliability in the fifth, sixth, seventh and eighth (ICC = 0.831, 95% CI -0.229;0.996). Inter-unit CV ranged from 2.08% (11.5 km/h) to 3.92% (8.5 km/h). Based on these findings, it was concluded that the 10 Hz Johan system offers an affordable valid and reliable tool for coaches and fitness trainers to monitor training and performance.
Disinfection of Contaminated Water by Using Solar Irradiation
Caslake, Laurie F.; Connolly, Daniel J.; Menon, Vilas; Duncanson, Catriona M.; Rojas, Ricardo; Tavakoli, Javad
2004-01-01
Contaminated water causes an estimated 6 to 60 billion cases of gastrointestinal illness annually. The majority of these cases occur in rural areas of developing nations where the water supply remains polluted and adequate sanitation is unavailable. A portable, low-cost, and low-maintenance solar unit to disinfect unpotable water has been designed and tested. The solar disinfection unit was tested with both river water and partially processed water from two wastewater treatment plants. In less than 30 min in midday sunlight, the unit eradicated more than 4 log10 U (99.99%) of bacteria contained in highly contaminated water samples. The solar disinfection unit has been field tested by Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente in Lima, Peru. At moderate light intensity, the solar disinfection unit was capable of reducing the bacterial load in a controlled contaminated water sample by 4 log10 U and disinfected approximately 1 liter of water in 30 min. PMID:14766599
Testing of refrigerant mixtures in residential heat pumps. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Judge, J.F.; Radermacher, R.
1995-08-01
To contribute to finding the proper substitute for R-22, a test facility was designed and built to measure the steady state and cyclic performance of two air-to-air heat pumps of 2 & 3 refrigeration-ton (RT) capacity. The performance of heat pumps is evaluated based on ASHRAE Standard 116-1983 {open_quotes}Method of Testing for Seasonal Efficiency of Unitary Air-conditioners and Heat Pumps{close_quotes} (47). This standard includes six steady-state tests; three cooling tests (A, B, and C) and three heating tests (High Temperature (47S), Frost Accumulation (35F), and Low Temperature (17L)). The standard also includes two cyclic tests; a cyclic cooling test (D)more » and a cyclic heating test (47C). The results of these tests are used to evaluate the seasonal performance of a heat pump. In the work presented here, two heat pumps (test units) are used. Test unit 1 is a 2 RT split heat pump system using a reciprocating compressor, a short tube, and a thermostatic expansion valve. Test unit 2 is a 3 RT split heat pump system using a scroll compressor and two thermostatic expansion valves. This study investigates four different possibilities for replacing R-22 with R-32/125/134a (30/10/60 wt.%) (Mixture 1) or R-32/125/134a (23/25/52 wt.%) (Mixture 2). The first and simplest scenario is the retrofit with no hardware modifications. The second possibility investigated is altering the refrigerant path to attain a near-counterflow configuration in the indoor coil for the heating mode. The third and most complex possibility is the soft optimization which consists of maximizing the COPs of R-22 and Mixture 2 in the heating and cooling modes by optimizing refrigerant charge and expansion devices. The fourth option investigated is the suction-line heat exchange (SLHX). In unit 1, the first, second, and third scenarios are investigated and in unit 2, the first, second, and fourth scenarios are investigated.« less
Cost-effectiveness of population based BRCA testing with varying Ashkenazi Jewish ancestry.
Manchanda, Ranjit; Patel, Shreeya; Antoniou, Antonis C; Levy-Lahad, Ephrat; Turnbull, Clare; Evans, D Gareth; Hopper, John L; Macinnis, Robert J; Menon, Usha; Jacobs, Ian; Legood, Rosa
2017-11-01
Population-based BRCA1/BRCA2 testing has been found to be cost-effective compared with family history-based testing in Ashkenazi-Jewish women were >30 years old with 4 Ashkenazi-Jewish grandparents. However, individuals may have 1, 2, or 3 Ashkenazi-Jewish grandparents, and cost-effectiveness data are lacking at these lower BRCA prevalence estimates. We present an updated cost-effectiveness analysis of population BRCA1/BRCA2 testing for women with 1, 2, and 3 Ashkenazi-Jewish grandparents. Decision analysis model. Lifetime costs and effects of population and family history-based testing were compared with the use of a decision analysis model. 56% BRCA carriers are missed by family history criteria alone. Analyses were conducted for United Kingdom and United States populations. Model parameters were obtained from the Genetic Cancer Prediction through Population Screening trial and published literature. Model parameters and BRCA population prevalence for individuals with 3, 2, or 1 Ashkenazi-Jewish grandparent were adjusted for the relative frequency of BRCA mutations in the Ashkenazi-Jewish and general populations. Incremental cost-effectiveness ratios were calculated for all Ashkenazi-Jewish grandparent scenarios. Costs, along with outcomes, were discounted at 3.5%. The time horizon of the analysis is "life-time," and perspective is "payer." Probabilistic sensitivity analysis evaluated model uncertainty. Population testing for BRCA mutations is cost-saving in Ashkenazi-Jewish women with 2, 3, or 4 grandparents (22-33 days life-gained) in the United Kingdom and 1, 2, 3, or 4 grandparents (12-26 days life-gained) in the United States populations, respectively. It is also extremely cost-effective in women in the United Kingdom with just 1 Ashkenazi-Jewish grandparent with an incremental cost-effectiveness ratio of £863 per quality-adjusted life-years and 15 days life gained. Results show that population-testing remains cost-effective at the £20,000-30000 per quality-adjusted life-years and $100,000 per quality-adjusted life-years willingness-to-pay thresholds for all 4 Ashkenazi-Jewish grandparent scenarios, with ≥95% simulations found to be cost-effective on probabilistic sensitivity analysis. Population-testing remains cost-effective in the absence of reduction in breast cancer risk from oophorectomy and at lower risk-reducing mastectomy (13%) or risk-reducing salpingo-oophorectomy (20%) rates. Population testing for BRCA mutations with varying levels of Ashkenazi-Jewish ancestry is cost-effective in the United Kingdom and the United States. These results support population testing in Ashkenazi-Jewish women with 1-4 Ashkenazi-Jewish grandparent ancestry. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-03-28
The study, conducted by Babcock and Wilcox, was funded by the U.S. Trade and Development agency on behalf of Enelven. In order to maximize generated power output and minimize operating costs at Planta Ramon Laguna, tests were done to evaluate the condition of equipment at the plant. In order to identify any damage and determine the operating output of each unit, assessments were done of the furnaces, boilers, generators and boiler feed pumps being used in the plant. The report presents the results of these tests. This is the second of three volumes and it includes the following section: (1)more » Condition Assessment of Unit RL-10 Boiler.« less
Flight test of an improved solid waste collection system
NASA Technical Reports Server (NTRS)
Thornton, W.; Brasseaux, H.; Whitmore, H.
1991-01-01
A system for human waste collection is described and evaluated on the basis of a prototype employed for the shuttle flight STS-35. The manually operated version of the unit is designed to collect, compact, and store human waste and cleaning material in replaceable volumes. The system is presented with illustrations and descriptions of the disposable pads that are used to clean the cylinder and occlusive air valves as well as seal the unit. Temporary retention and waste entrainment are provided by the variable airflow in the manual unit tested. The prototype testing indicates that sufficient airflow is achieved at 45 CFM and that the stowage volume (18.7 cu in.) is adequate for storing human waste with minimal logistical support. Higher compaction pressure and the use of a directed airstream are proposed for improving the packing efficiency of the unit.
Eight-Year Review of Bordetella pertussis Testing Reveals Seasonal Pattern in the United States.
Bhatti, Micah M; Rucinski, Stefanea L; Schwab, Jeramy J; Cole, Nicolynn C; Gebrehiwot, Senait A; Patel, Robin
2017-03-01
Review of Bordetella pertussis polymerase chain reaction testing from 2007 through 2014 revealed a yearly spike in positivity rates during the summer throughout the United States. Paradoxically, the highest test volumes occurred outside of this time frame, which provides an opportunity for improved test utilization. © The Author 2015. Published by Oxford University Press on behalf of the Pediatric Infectious Diseases Society. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
1984-01-01
Subtitle) PHASE II TESTING AT 32BA3, S. TYPE OF REPORT & PERIOD COVERED BARNES COUNTY, NORTH DAKOTA. Final 6. PERFORMING ORG. REPORT NUMBER 7 . AUTHOR(a...3 4. Countour map of 32BA418 showing locations of auger test units, 1 m2 test units, cutbank profile (A - A’) and grid system ......... 7 5...Physiographic subdivisions, North Dakota ....... ............. 9 6. Vegetation zones, North Dakota ...... ................... .11 7 . Great Plains
NASA Technical Reports Server (NTRS)
Verrilli, Michael J.; Ellis, J. Rodney; Swindeman, Robert W.
1990-01-01
The American Society for Testing and Materials (ASTM) standard E606-80 is the most often used recommended testing practice for low-cycle-fatigue (LCF) testing in the United States. The standard was first adopted in 1977 for LCF testing at room temperature and was modified in 1980 to include high-temperature testing practices. Current activity within ASTM is aimed at extending the E606-80 recommended practices to LCF under thermomechanical conditions, LCF in high-pressure hydrogen, and LCF in metal-matrix composite materials. Interlaboratory testing programs conducted to generate a technical base for modifying E606-80 for the aforementioned LCF test types are discussed.
Zhang, Yongquan; Tang, Huiming; Li, Changdong; Lu, Guiying; Cai, Yi; Zhang, Junrong; Tan, Fulin
2018-01-14
The physical model test of landslides is important for studying landslide structural damage, and parameter measurement is key in this process. To meet the measurement requirements for deep displacement in landslide physical models, an automatic flexible inclinometer probe with good coupling and large deformation capacity was designed. The flexible inclinometer probe consists of several gravity acceleration sensing units that are protected and positioned by silicon encapsulation, all the units are connected to a 485-comunication bus. By sensing the two-axis tilt angle, the direction and magnitude of the displacement for a measurement unit can be calculated, then the overall displacement is accumulated according to all units, integrated from bottom to top in turn. In the conversion from angle to displacement, two spline interpolation methods are introduced to correct and resample the data; one is to interpolate the displacement after conversion, and the other is to interpolate the angle before conversion; compared with the result read from checkered paper, the latter is proved to have a better effect, with an additional condition that the displacement curve move up half the length of the unit. The flexible inclinometer is verified with respect to its principle and arrangement by a laboratory physical model test, and the test results are highly consistent with the actual deformation of the landslide model.
Zhang, Yongquan; Tang, Huiming; Li, Changdong; Lu, Guiying; Cai, Yi; Zhang, Junrong; Tan, Fulin
2018-01-01
The physical model test of landslides is important for studying landslide structural damage, and parameter measurement is key in this process. To meet the measurement requirements for deep displacement in landslide physical models, an automatic flexible inclinometer probe with good coupling and large deformation capacity was designed. The flexible inclinometer probe consists of several gravity acceleration sensing units that are protected and positioned by silicon encapsulation, all the units are connected to a 485-comunication bus. By sensing the two-axis tilt angle, the direction and magnitude of the displacement for a measurement unit can be calculated, then the overall displacement is accumulated according to all units, integrated from bottom to top in turn. In the conversion from angle to displacement, two spline interpolation methods are introduced to correct and resample the data; one is to interpolate the displacement after conversion, and the other is to interpolate the angle before conversion; compared with the result read from checkered paper, the latter is proved to have a better effect, with an additional condition that the displacement curve move up half the length of the unit. The flexible inclinometer is verified with respect to its principle and arrangement by a laboratory physical model test, and the test results are highly consistent with the actual deformation of the landslide model. PMID:29342902
NASA Technical Reports Server (NTRS)
Lewandowski, Edward J.
2013-01-01
The Advanced Stirling Radioisotope Generator (ASRG) is a high-efficiency generator being developed for potential use on a Discovery 12 space mission. Lockheed Martin designed and fabricated the ASRG Engineering Unit (EU) under contract to the Department of Energy. This unit was delivered to NASA Glenn Research Center in 2008 and has been undergoing extended operation testing to generate long-term performance data for an integrated system. It has also been used for tests to characterize generator operation while varying control parameters and system inputs, both when controlled with an alternating current (AC) bus and with a digital controller. The ASRG EU currently has over 27,000 hours of operation. This paper summarizes all of the tests that have been conducted on the ASRG EU over the past 3 years and provides an overview of the test results and what was learned.
United3D: a protein model quality assessment program that uses two consensus based methods.
Terashi, Genki; Oosawa, Makoto; Nakamura, Yuuki; Kanou, Kazuhiko; Takeda-Shitaka, Mayuko
2012-01-01
In protein structure prediction, such as template-based modeling and free modeling (ab initio modeling), the step that assesses the quality of protein models is very important. We have developed a model quality assessment (QA) program United3D that uses an optimized clustering method and a simple Cα atom contact-based potential. United3D automatically estimates the quality scores (Qscore) of predicted protein models that are highly correlated with the actual quality (GDT_TS). The performance of United3D was tested in the ninth Critical Assessment of protein Structure Prediction (CASP9) experiment. In CASP9, United3D showed the lowest average loss of GDT_TS (5.3) among the QA methods participated in CASP9. This result indicates that the performance of United3D to identify the high quality models from the models predicted by CASP9 servers on 116 targets was best among the QA methods that were tested in CASP9. United3D also produced high average Pearson correlation coefficients (0.93) and acceptable Kendall rank correlation coefficients (0.68) between the Qscore and GDT_TS. This performance was competitive with the other top ranked QA methods that were tested in CASP9. These results indicate that United3D is a useful tool for selecting high quality models from many candidate model structures provided by various modeling methods. United3D will improve the accuracy of protein structure prediction.
Combination of an electrolytic pretreatment unit with secondary water reclamation processes
NASA Technical Reports Server (NTRS)
Wells, G. W.; Bonura, M. S.
1973-01-01
The design and fabrication of a flight concept prototype electrolytic pretreatment unit (EPU) and of a contractor-furnished air evaporation unit (AEU) are described. The integrated EPU and AEU potable water recovery system is referred to as the Electrovap and is capable of processing the urine and flush water of a six-man crew. Results of a five-day performance verification test of the Electrovap system are presented and plans are included for the extended testing of the Electrovap to produce data applicable to the combination of electrolytic pretreatment with most final potable water recovery systems. Plans are also presented for a program to define the design requirements for combining the electrolytic pretreatment unit with a reverse osmosis final processing unit.
Test Driven Development: Lessons from a Simple Scientific Model
NASA Astrophysics Data System (ADS)
Clune, T. L.; Kuo, K.
2010-12-01
In the commercial software industry, unit testing frameworks have emerged as a disruptive technology that has permanently altered the process by which software is developed. Unit testing frameworks significantly reduce traditional barriers, both practical and psychological, to creating and executing tests that verify software implementations. A new development paradigm, known as test driven development (TDD), has emerged from unit testing practices, in which low-level tests (i.e. unit tests) are created by developers prior to implementing new pieces of code. Although somewhat counter-intuitive, this approach actually improves developer productivity. In addition to reducing the average time for detecting software defects (bugs), the requirement to provide procedure interfaces that enable testing frequently leads to superior design decisions. Although TDD is widely accepted in many software domains, its applicability to scientific modeling still warrants reasonable skepticism. While the technique is clearly relevant for infrastructure layers of scientific models such as the Earth System Modeling Framework (ESMF), numerical and scientific components pose a number of challenges to TDD that are not often encountered in commercial software. Nonetheless, our experience leads us to believe that the technique has great potential not only for developer productivity, but also as a tool for understanding and documenting the basic scientific assumptions upon which our models are implemented. We will provide a brief introduction to test driven development and then discuss our experience in using TDD to implement a relatively simple numerical model that simulates the growth of snowflakes. Many of the lessons learned are directly applicable to larger scientific models.
Performance analysis and an assessment of operational issues of Ya-21U
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paramonov, D.V.; El-Genk, M.S.
1996-03-01
Extensive testing of the Soviet made TOPAZ-II space nuclear power system unit designated {open_quote}{open_quote}Ya-21U{close_quote}{close_quote} was conducted both in the USSR (1989{endash}1990) and in the US (August 1993 to March 1995). The unit underwent a total of 15 tests for a cumulative test/operation time of almost 8000 hours. These tests included steady-state operation at different power levels, fast startups and power optimizations. Leaks were detected in some of the Thermionic Fuel Elements (TFEs) after the first test in the US. These leaks that facilitated air incursion into the interelectrode gap caused operational changes in both electric power and conversion efficiency andmore » changed the optimum cesium pressure and load voltage. Additional changes in operational performance were detected following shock and vibration tests performed in August 1994. Test data was examined and analyzed to assess the performance of not only individual TFEs, and also the whole Ya-21U unit, and identify causes for measured operational performance changes; most probable causes were identified and discussed. The Ya-21U unit remained operational throughout extensive testing for 8000 hours at conditions far exceeding the design limits of the TOPAZ-II system. No single TFE was damaged during testing and measured operational performance changes were uniform among working section TFEs. In addition to providing a unique knowledge base for future development and operation of thermionic power systems, the test results testify to the reliability and ruggedness of the TOPAZ-II system design. {copyright} {ital 1996 American Institute of Physics.}« less
Physical Science, Units 5 and 6, Field Test Copy.
ERIC Educational Resources Information Center
Washington State Univ., Pullman.
This student workbook contains units five and six of a six-unit physical science course. The program is intended for high school students who have not had a chemistry or physics course, and is designed to be self instructional. Unit five involves experiments and problems in these subject areas: temperature versus heat; units of heat; specific…
Advance prototype silver ion water bactericide system
NASA Technical Reports Server (NTRS)
Jasionowski, W. J.; Allen, E. T.
1974-01-01
An advance prototype unit was designed and fabricated to treat anticipated fuel cell water. The unit is a single canister that contains a membrane-type prefilter and a silver bromide contacting bed. A seven day baseline simulated mission test was performed; the performance was satisfactory and the effluent water was within all specifications for potability. After random vibrations another seven day simulated mission test was performed, and results indicate that simulated launch vibrations have no effects on the design and performance of the advanced prototype. Bench tests and accelerated breadboard tests were conducted to define the characteristics of an upgraded model of the advance prototype unit which would have 30 days of operating capability. A preliminary design of a silver ion generator for the shuttle orbiter was also prepared.
Testing the Birth Unit Design Spatial Evaluation Tool (BUDSET) in Australia: a pilot study.
Foureur, Maralyn J; Leap, Nicky; Davis, Deborah L; Forbes, Ian F; Homer, Caroline E S
2011-01-01
To pilot test the Birth Unit Design Spatial Evaluation Tool (BUDSET) in an Australian maternity care setting to determine whether such an instrument can measure the optimality of different birth settings. Optimally designed spaces to give birth are likely to influence a woman's ability to experience physiologically normal labor and birth. This is important in the current industrialized environment, where increased caesarean section rates are causing concerns. The measurement of an optimal birth space is currently impossible, because there are limited tools available. A quantitative study was undertaken to pilot test the discriminant ability of the BUDSET in eight maternity units in New South Wales, Australia. Five auditors trained in the use of the BUDSET assessed the birth units using the BUDSET, which is based on 18 design principles and is divided into four domains (Fear Cascade, Facility, Aesthetics, and Support) with three to eight assessable items in each. Data were independently collected in eight birth units. Values for each of the domains were aggregated to provide an overall Optimality Score for each birth unit. A range of Optimality Scores was derived for each of the birth units (from 51 to 77 out of a possible 100 points). The BUDSET identified units with low-scoring domains. Essentially these were older units and conventional labor ward settings. The BUDSET provides a way to assess the optimality of birth units and determine which domain areas may need improvement. There is potential for improvements to existing birth spaces, and considerable improvement can be made with simple low-cost modifications. Further research is needed to validate the tool.
August 5, 1963-President Kennedy's Nuclear Test Ban Treaty signed in Moscow, Russia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kennedy, John F.
On August 5, 1963, after more than eight years of negotiations, the United States, the United Kingdom, and the Soviet Union signed the Limited Nuclear Test Ban Treaty. The destruction of Hiroshima and Nagasaki by atomic bombs marked the end of World War II and the beginning of the nuclear age. As tensions between East and West settled into a Cold War, scientists in the United States, Great Britain, and the Soviet Union conducted tests and developed more powerful nuclear weapons. In 1959, radioactive deposits were found in wheat and milk in the northern United States. As scientists and themore » public gradually became aware of the dangers of radioactive fallout, they began to raise their voices against nuclear testing. Leaders and diplomats of several countries sought to address the issue. In May 1955, the United Nations Disarmament Commission brought together the United States, the United Kingdom, Canada, France, and the Soviet Union to begin negotiations on ending nuclear weapons testing. Conflict soon arose over inspections to verify underground testing. The Soviet Union feared that on-site inspections could lead to spying that might expose the Soviets' vastly exaggerated claims of the number of deliverable nuclear weapons. As negotiators struggled over differences, the Soviet Union and the United States suspended nuclear tests—a moratorium that lasted from November 1958 to September 1961. John F. Kennedy had supported ban on nuclear weapons testing since 1956. He believed a ban would prevent other countries from obtaining nuclear weapons, and took a strong stand on the issue in the 1960 presidential campaign. Once elected, President Kennedy pledged not to resume testing in the air and promised to pursue all diplomatic efforts for a test ban treaty before resuming underground testing. He envisioned the test ban as a first step to nuclear disarmament. President Kennedy met with Soviet Premier Khrushchev in Vienna in June 1961, just five weeks after the humiliating defeat of the US-sponsored invasion of Cuba at the Bay of Pigs. Khrushchev took a hard line at the summit. He announced his intention to cut off Western access to Berlin and threatened war if the United States or its allies tried to stop him. Many US diplomats felt that Kennedy had not stood up to the Soviet premier at the summit and left Khrushchev with the impression that he was a weak leader. President Kennedy's political and military advisers feared that the Soviet Union had continued secret underground testing and made gains in nuclear technology. They pressured Kennedy to resume testing. And, according to a Gallup poll in July 1961, the public approved of testing by a margin of two-to-one. In August 1961, the Soviet Union announced its intention to resume atmospheric testing, and over the next three months it conducted 31 nuclear tests. It exploded the largest nuclear bomb in history—58 megatons—4,000 times more powerful than the bomb dropped on Hiroshima. In his commencement address at American University on June 10, 1963, Kennedy announced a new round of high-level arms negotiations with the Russians. He boldly called for an end to the Cold War. "If we cannot end our differences," he said, "at least we can help make the world a safe place for diversity." The Soviet government broadcast a translation of the entire speech, and allowed it to be reprinted in the controlled Soviet press. The Limited Nuclear Test Ban treaty was signed in Moscow on August 5, 1963, by US Secretary Dean Rusk, Soviet Foreign Minister Andrei Gromyko, and British Foreign Secretary Lord Home—one day short of the 18th anniversary of the dropping of an atomic bomb on Hiroshima. Over the next two months, President Kennedy convinced a fearful public and a divided Senate to support the treaty. The Senate approved the treaty on September 23, 1963, by an 80-19 margin. Kennedy signed the ratified treaty on October 7, 1963. The treaty: prohibited nuclear weapons tests or other nuclear explosions under water, in the atmosphere, or in outer space allowed underground nuclear tests as long as no radioactive debris falls outside the boundaries of the nation conducting the test pledged signatories to work towards complete disarmament, an end to the armaments race, and an end to the contamination of the environment by radioactive substances. Thirty-three years later, the United Nations General Assembly adopted the Comprehensive Nuclear Test Ban Treaty. Signed by 71 nations, including those possessing nuclear weapons, the treaty prohibited all nuclear test explosions including those conducted underground. Though it was signed by President Bill Clinton, the Senate rejected the treaty by a vote of 51 to 48.« less
Code of Federal Regulations, 2014 CFR
2014-07-01
....2Response Time Test. Conduct this test once prior to each test series. Introduce zero gas into the... analysis. 3.0Definitions 3.1Capture efficiency (CE). The weight per unit time of SF6 entering the control device divided by the weight per unit time of SF6 released through manifolds at multiple locations within...
Code of Federal Regulations, 2010 CFR
2010-07-01
....2Response Time Test. Conduct this test once prior to each test series. Introduce zero gas into the... analysis. 3.0Definitions 3.1Capture efficiency (CE). The weight per unit time of SF6 entering the control device divided by the weight per unit time of SF6 released through manifolds at multiple locations within...
Code of Federal Regulations, 2013 CFR
2013-07-01
....2Response Time Test. Conduct this test once prior to each test series. Introduce zero gas into the... analysis. 3.0Definitions 3.1Capture efficiency (CE). The weight per unit time of SF6 entering the control device divided by the weight per unit time of SF6 released through manifolds at multiple locations within...
Code of Federal Regulations, 2011 CFR
2011-07-01
....2Response Time Test. Conduct this test once prior to each test series. Introduce zero gas into the... analysis. 3.0Definitions 3.1Capture efficiency (CE). The weight per unit time of SF6 entering the control device divided by the weight per unit time of SF6 released through manifolds at multiple locations within...
United Stirling's Solar Engine Development: the Background for the Vanguard Engine
NASA Technical Reports Server (NTRS)
Holgersson, S.
1984-01-01
The development and testing resulting in the Vanguard engine and some of the characteristics of the Stirling engine based power conversion unit are described. The major part of the solar engine development is concentrated to the three different areas, the receiver, the lubrication system and the control system. Five engines are on test within the solar project. The function of the components are validated in actual solar tests.
ERIC Educational Resources Information Center
Kouimanos, John, Ed.
Accompanying a multimedia resource unit on aspects of rice growing, volume eight of the geography collection includes a section introducing terminology, a viewing guide to the filmstrips and unit test items. Rice farming and marketing in Australia and growing methods in several countries are presented with regional studies in southeast Australia.…
ETR ELECTRICAL BUILDING, TRA648. EMERGENCY STANDBY GENERATOR AND DIESEL UNIT. ...
ETR ELECTRICAL BUILDING, TRA-648. EMERGENCY STANDBY GENERATOR AND DIESEL UNIT. METAL ROOF AND PUMICE BLOCK WALLS. CAMERA FACING SOUTHWEST. INL NEGATIVE NO. 56-3708. R.G. Larsen, Photographer, 11/13/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Astronaut Bruce McCandless during an underwater test MMU/FSS in bldg 29 WETF
1981-08-04
Astronaut Bruce McCandless during an underwater test of the Manned Maneuvering Unit (MMU) Flight Support Station (FSS) donning and doffing in the Bldg 29 Weightless Environment Training Facility (WETF). View is of McCandless wearing the extravehicular mobility unit (EMU), stepping into the MMU.
DOT National Transportation Integrated Search
2002-06-01
The objective of this study was to investigate the effect of moisture content and dry unit weight on the resilient characteristics of subgrade soil predicted by the cone penetration test. An experimental program was conducted in which cone penetratio...
Walker, Tiffany A; Lockhart, Shawn R; Beekmann, Susan E; Polgreen, Philip M; Santibanez, Scott; Mody, Rajal K; Beer, Karlyn D; Chiller, Tom M; Jackson, Brendan R
2018-01-01
Infections caused by pan-azole-resistant Aspergillus fumigatus strains have emerged in Europe and recently in the United States. Physicians specializing in infectious diseases reported observing pan-azole-resistant infections and low rates of susceptibility testing, suggesting the need for wider-scale testing.
Lockhart, Shawn R.; Beekmann, Susan E.; Polgreen, Philip M.; Santibanez, Scott; Mody, Rajal K.; Beer, Karlyn D.; Chiller, Tom M.; Jackson, Brendan R.
2018-01-01
Infections caused by pan–azole-resistant Aspergillus fumigatus strains have emerged in Europe and recently in the United States. Physicians specializing in infectious diseases reported observing pan–azole-resistant infections and low rates of susceptibility testing, suggesting the need for wider-scale testing. PMID:29261092
Code of Federal Regulations, 2013 CFR
2013-07-01
... (NSPS) for Particulate Matter (PM) 4 Table 4 to Subpart UUU of Part 63 Protection of Environment... Units Pt. 63, Subpt. UUU, Table 4 Table 4 to Subpart UUU of Part 63—Requirements for Performance Tests...
Code of Federal Regulations, 2012 CFR
2012-07-01
... (NSPS) for Particulate Matter (PM) 4 Table 4 to Subpart UUU of Part 63 Protection of Environment... Units Pt. 63, Subpt. UUU, Table 4 Table 4 to Subpart UUU of Part 63—Requirements for Performance Tests...
Code of Federal Regulations, 2014 CFR
2014-07-01
... (NSPS) for Particulate Matter (PM) 4 Table 4 to Subpart UUU of Part 63 Protection of Environment... Units Pt. 63, Subpt. UUU, Table 4 Table 4 to Subpart UUU of Part 63—Requirements for Performance Tests...
NASA Astrophysics Data System (ADS)
Chu, Hsiao-Ping; Chang, Tsangyao; Chang, Hsu-Ling; Su, Chi-Wei; Yuan, Young
2007-10-01
Here, the Panel seemingly unrelated regressions augmented Dickey-Fuller test (SURADF) test, first introduced and advanced by Breuer et al. [Misleading inferences from panel unit-root tests with an illustration from purchasing power parity, Rev. Int. Econ. 9(3) (2001) 482-493], is used to investigate the mean-reverting behavior of the current account of 48 African countries during the 1980-2004 periods. The empirical results from numerous panel-based unit root tests, conducted earlier, indicated that the current account of each of these countries is stationary; however, when Breuer et al.'s (2001) Panel SURADF test is conducted, it is found that a unit root exists in the current account of 11 of the countries studied. These results have one extremely important policy implication for the 48 African countries studied: the current account deficit of most is sustainable, and thus signifying that those nations should have no incentive to default on their international debt.
Design of a Facility to Test the Advanced Stirling Radioisotope Generator Engineering Unit
NASA Technical Reports Server (NTRS)
Lewandowski, Edward J.; Schreiber, Jeffrey G.; Oriti, Salvatore M.; Meer, David W.; Brace, Michael H.; Dugala, Gina
2009-01-01
The Advanced Stirling Radioisotope Generator (ASRG) is being considered to power deep space missions. An engineering unit, the ASRG-EU, was designed and fabricated by Lockheed Martin under contract to the Department of Energy. This unit is currently on an extended operation test at NASA Glenn Research Center to generate performance data and validate the life and reliability predictions for the generator and the Stirling convertors. A special test facility was designed and built for testing the ASRG-EU. Details of the test facility design are discussed. The facility can operate the convertors under AC bus control or with the ASRG-EU controller. It can regulate input thermal power in either a fixed temperature or fixed power mode. An enclosure circulates cooled air around the ASRG-EU to remove heat rejected from the ASRG-EU by convection. A custom monitoring and data acquisition system supports the test. Various safety features, which allow 2417 unattended operation, are discussed.
Experimental Results From a 2kW Brayton Power Conversion Unit
NASA Technical Reports Server (NTRS)
Hervol, David; Mason, Lee; Birchenough, Arthur
2003-01-01
This paper presents experimental test results from operation of a 2 kWe Brayton power conversion unit. The Brayton converter was developed for a solar dynamic power system flight experiment planned for the Mir Space Station in 1997. The flight experiment was cancelled, but the converter was tested at Glenn Research Center as part of the Solar Dynamic Ground Test Demonstration system which included a solar concentrator, heat receiver, and space radiator. In preparation for the current testing, the heat receiver was removed and replaced with an electrical resistance heater, simulating the thermal input of a steady-state nuclear source. The converter was operated over a full range of thermal input power levels and rotor speeds to generate an overall performance map. The converter unit will serve as the centerpiece of a Nuclear Electric Propulsion Testbed at Glenn. Future potential uses for the Testbed include high voltage electrical controller development, integrated electric thruster testing and advanced radiator demonstration testing to help guide high power Brayton technology development for Nuclear Electric Propulsion (NEP).
Will the leading firm continue to dominate the market in the Taiwan notebook industry?
NASA Astrophysics Data System (ADS)
Chu, Hsiao-Ping; Yeh, Ming-Liang; Sher, Peter J.; Chiu, Yi-Chia
2007-09-01
This study investigates whether the market share leader in the notebook industry in Taiwan is likely to maintain its dominant position. Market share data are used to investigate the intensity of competitiveness in the industry, and data on the gap in market shares are employed to elucidate the dominance of the leading firm in Taiwan's notebook industry during the 1998-2004 period. The newly developed Panel SURADF tests advanced by Breuer et al. [Misleading inferences from panel unit root tests with an illustration from purchasing power parity, Rev. Int. Econ. 9 (3) (2001) 482-493] are employed to determine whether the market share gap is stationary or not. Unlike other panel-based unit root tests which are joint tests of a unit root for all members of a panel and are incapable of determining the mix of I(0) and I(1) series in a panel setting, the Panel SURADF tests have the advantage of being able to investigate a separate unit root null hypothesis for each individual panel member and are, therefore, able to identify how many and which series in a panel are stationary processes. The empirical results from several panel-based unit root tests substantiate that the market shares of the firms studied here are non-stationary, indicating that Taiwan's notebook industry is highly competitive; however, Breuer et al.'s [12] Panel SURADF tests unequivocally show that only Compal is stationary with respect to market share gap. In terms of sales volume, Compal is the second largest firm in the notebook industry in Taiwan, and the results indicate that it alone has the opportunity to become the market share leader in the notebook industry.
Alter, H J; Epstein, J S; Swenson, S G; VanRaden, M J; Ward, J W; Kaslow, R A; Menitove, J E; Klein, H G; Sandler, S G; Sayers, M H
1990-11-08
We performed a multicenter study in 1989 to determine whether screening whole-blood donors for human immunodeficiency virus type 1 (HIV-1) p24 antigen would improve transfusion safety by identifying carriers of the virus who are seronegative for HIV-1 antibody. More than 500,000 donations were tested at 13 U.S. blood centers with test kits from two manufacturers. Units found repeatedly reactive were retested in a central laboratory; if the results were positive, they were confirmed by a neutralization assay. A subgroup of units was also tested for HIV-1 by the polymerase chain reaction. Selected donors confirmed or not confirmed as having p24 antigen were contacted for follow-up interviews to identify risk factors and undergo retesting for HIV-1 markers. Positive tests for p24 antigen were confirmed by neutralization in five donors (0.001 percent of all donations tested), all of whom were also positive for HIV-1 antibody and HIV-1 by polymerase chain reaction. Three of the antigen-positive donors had other markers of infectious disease that would have resulted in the exclusion of their blood; two had risk factors for HIV-1 that should have led to self-exclusion. Of 220 blood units with repeatedly reactive p24 antigen whose presence could not be confirmed by neutralization (0.04 percent of the donations studied), none were positive for HIV-1 antibody, HIV-1 by polymerase chain reaction (120 units tested), or virus culture (76 units tested)--attesting to the specificity of confirmatory neutralization. The finding that no donation studied was positive for p24 antigen and negative for HIV-1 antibody suggests that screening donors for p24 antigen with tests of the current level of sensitivity would not add substantially to the safety of the U.S. blood supply.
Gonthier, Gerard
2012-01-01
Two test wells were completed in Pooler, Georgia, in 2011 to investigate the potential of using the Lower Floridan aquifer as a source of water for municipal use. One well was completed in the Lower Floridan aquifer at a depth of 1,120 feet (ft) below land surface; the other well was completed in the Upper Floridan aquifer at a depth of 486 ft below land surface. At the Pooler test site, the U.S. Geological Survey performed flowmeter surveys, packer-isolated slug tests within the Lower Floridan confining unit, slug tests of the entire Floridan aquifer system, and aquifer tests of the Upper and Lower Floridan aquifers. Drill cuttings, geophysical logs, and borehole flowmeter surveys indicate that the Upper Floridan aquifer extends 333 –515 ft below land surface, the Lower Floridan confining unit extends 515–702 ft below land surface, and the Lower Floridan aquifer extends 702–1,040 ft below land surface. Flowmeter surveys indicate that the Upper Floridan aquifer contains two water-bearing zones at depth intervals of 339 –350 and 375–515 ft; the Lower Floridan confining unit contains one zone at a depth interval of 550–620 ft; and the Lower Floridan aquifer contains five zones at depth intervals of 702–745, 745–925, 925–984, 984–1,015, and 1,015–1,040 ft. Flowmeter testing of the test borehole open to the entire Floridan aquifer system indicated that the Upper Floridan aquifer contributed 92.4 percent of the total flow rate of 708 gallons per minute; the Lower Floridan confining unit contributed 3.0 percent; and the Lower Floridan aquifer contributed 4.6 percent. Horizontal hydraulic conductivity of the Lower Floridan confining unit derived from slug tests within three packer-isolated intervals ranged from 0.5 to 10 feet per day (ft/d). Aquifer-test analyses yielded values of transmissivity for the Upper Floridan aquifer, Lower Floridan confining unit, and the Lower Floridan aquifer of 46,000, 700, and 4,000 feet squared per day (ft2/d), respectively. Horizontal hydraulic conductivity of 4 ft/d for the Lower Floridan confining unit, derived from aquifer-test analyses, is near the midrange for values derived from packer-isolated slug tests. The transmissivity of the entire Floridan aquifer system derived from aquifer-test analyses totals about 51,000 ft2/d, similar to the value of 58,000 ft2/d derived from open slug tests on the entire Floridan aquifer system. Water-level data for each aquifer test were filtered for external influences such as barometric pressure, earth-tide effects, and long-term trends to enable detection of small (less than 1 foot) water-level responses to aquifer-test pumping. During the 72-hour aquifer test of pumping the Lower Floridan aquifer, a drawdown response of 51.7 ft was observed in the Lower Floridan pumped well and a drawdown response of 0.9 foot was observed in the Upper Floridan observation well located 85 ft from the pumped well.
Advanced Stirling Radioisotope Generator Engineering Unit 2 (ASRG EU2) Final Assembly
NASA Technical Reports Server (NTRS)
Oriti, Salvatore M.
2015-01-01
NASA Glenn Research Center (GRC) has recently completed the assembly of a unique Stirling generator test article for laboratory experimentation. Under the Advanced Stirling Radioisotope Generator (ASRG) flight development contract, NASA GRC initiated a task to design and fabricate a flight-like generator for in-house testing. This test article was given the name ASRG Engineering Unit 2 (EU2) as it was effectively the second engineering unit to be built within the ASRG project. The intent of the test article was to duplicate Lockheed Martin's qualification unit ASRG design as much as possible to enable system-level tests not previously possible at GRC. After the cancellation of the ASRG flight development project, the decision was made to continue the EU2 build, and make use of a portion of the hardware from the flight development project. GRC and Lockheed Martin engineers collaborated to develop assembly procedures, leveraging the valuable knowledge gathered by Lockheed Martin during the ASRG development contract. The ASRG EU2 was then assembled per these procedures at GRC with Lockheed Martin engineers on site. The assembly was completed in August 2014. This paper details the components that were used for the assembly, and the assembly process itself.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kjeldsen, Lisbeth Stigaard; Ghisari, Mandana; Bonefeld-Jørgensen, Eva Cecilie, E-mail: ebj@mil.au.dk
The endocrine-disrupting potential of pesticides is of health concern, since they are found ubiquitously in the environment and in food items. We investigated in vitro effects on estrogen receptor (ER) and androgen receptor (AR) transactivity, and aromatase enzyme activity, of the following pesticides: 2-methyl-4-chlorophenoxyacetic acid (MCPA), terbuthylazine, iodosulfuron-methyl-sodium, mesosulfuron-methyl, metsulfuron-methyl, chlormequat chloride, bitertanol, propiconazole, prothioconazole, mancozeb, cypermethrin, tau fluvalinate, malathion and the metabolite ethylene thiourea (ETU). The pesticides were analyzed alone and in selected mixtures. Effects of the pesticides on ER and AR function were assessed in human breast carcinoma MVLN cells and hamster ovary CHO-K1 cells, respectively, using luciferasemore » reporter gene assays. Effects on aromatase enzyme activity were analyzed in human choriocarcinoma JEG-3 cells, employing the classical [{sup 3}H]{sub 2}O method. Five pesticides (terbuthylazine, propiconazole, prothioconazole, cypermethrin and malathion) weakly induced the ER transactivity, and three pesticides (bitertanol, propiconazole and mancozeb) antagonized the AR activity in a concentration-dependent manner. Three pesticides (terbuthylazine, propiconazole and prothioconazole) weakly induced the aromatase activity. In addition, two mixtures, consisting of three pesticides (bitertanol, propiconazole, cypermethrin) and five pesticides (terbuthylazine, bitertanol, propiconazole, cypermethrin, malathion), respectively, induced the ER transactivity and aromatase activity, and additively antagonized the AR transactivity. In conclusion, our data suggest that currently used pesticides possess endocrine-disrupting potential in vitro which can be mediated via ER, AR and aromatase activities. The observed mixture effects emphasize the importance of considering the combined action of pesticides in order to assure proper estimations of related health effect risks. - Highlights: • Currently used pesticides possess endocrine-disrupting (ED) potential in vitro. • ED effects can be mediated via sex hormone receptors and/or the aromatase enzyme. • Additive mixture effects on androgen receptor transactivity were observed.« less
Luo, Wenqin; Fu, Chengyu; Li, Renfu; Liu, Yongsheng; Zhu, Haomiao; Chen, Xueyuan
2011-11-04
A comprehensive survey of electronic structure and optical properties of rare-earth ions embedded in semiconductor nanocrystals (NCs) is of vital importance for their potential applications in areas as diverse as luminescent bioprobes, lighting, and displays. Er3+ -doped anatase TiO2 NCs, synthesized via a facile sol-gel solvothermal method, exhibit intense and well-resolved intra-4f emissions of Er3+ . Crystal-field (CF) spectra of Er3+ in TiO2 NCs are systematically studied by means of high-resolution emission and excitation spectra at 10-300 K. The CF analysis of Er3+ assuming a site symmetry of C(2v) yields a small root-mean-square deviation of 25.1 cm(-1) and reveals the relatively large CF strength (549 cm(-1) ) of Er3+, thus verifying the rationality of the C(2v) symmetry assignment of Er3+ in anatase TiO2 NCs. Based on a simplified thermalization model for the temperature-dependent photoluminescence (PL) dynamics from (4) S(3/2) , the intrinsic radiative luminescence lifetimes of (4) S(3/2) and (2) H(11/2) are experimentally determined to be 3.70 and 1.73 μs, respectively. Green and red upconversion (UC) luminescence of Er3+ can be achieved upon laser excitation at 974.5 nm. The UC intensity of Er3+ in Yb/Er-codoped NCs is found to be about five times higher than that of Er-singly-doped counterparts as a result of efficient Yb3+ sensitization and energy transfer upconversion (ETU) evidenced by its distinct UC luminescence dynamics. Furthermore, the origin of defect luminescence is revealed based on the temperature-dependent PL spectra upon excitation above the TiO2 bandgap at 325 nm. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Field Test of the Unit Equal Opportunity Training Diagnosis and Assessment System (TDAS)
1980-02-01
Reseiirch Note 80-38 In U FIELD TEST OF THE UNIT EQUAL OPPORTUNITY TRAINING DIAGNOSIS AND ASSESSMENT SYSTEM (TDAS) 0 Dale K. Brown Human Sciences... Social Sciences February 1980 S Aoproved for public release; distribution unlimited. 84 11 O6 0 0- 7 9 THIS REPORT IS INCOMPLETE BUT IS THE BEST AVAILABLE...likely to be a unit problem area to that least likely. Four attitude scales are also included, as is a measure of knowledge of Army equal opportunity
Pathogen Reduction of Fresh Whole Blood for Military and Civilian Use
2010-04-01
NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR( S ) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME( S ) AND...MONITORING AGENCY NAME( S ) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM( S ) 11. SPONSOR/MONITOR’S REPORT NUMBER( S ) 12. DISTRIBUTION/AVAILABILITY STATEMENT...treatment with 80 J/mLRBC in the Mirasol System. Strain of bacteria tested # of units positive/ # of units tested Serratia marcescens 0/3 Yersinia
49 CFR 234.253 - Flashing light units and lamp voltage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Flashing light units and lamp voltage. 234.253....253 Flashing light units and lamp voltage. (a) Each flashing light unit shall be inspected when... with installation specifications. (b) Lamp voltage shall be tested when installed and at least once...
49 CFR 234.253 - Flashing light units and lamp voltage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Flashing light units and lamp voltage. 234.253....253 Flashing light units and lamp voltage. (a) Each flashing light unit shall be inspected when... with installation specifications. (b) Lamp voltage shall be tested when installed and at least once...
49 CFR 234.253 - Flashing light units and lamp voltage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Flashing light units and lamp voltage. 234.253....253 Flashing light units and lamp voltage. (a) Each flashing light unit shall be inspected when... with installation specifications. (b) Lamp voltage shall be tested when installed and at least once...
Comparative performance tests on the Mod-2, 2.5-mW wind turbine with and without vortex generators
NASA Technical Reports Server (NTRS)
Miller, G. E.
1995-01-01
A test program was conducted on the third Mod-2 unit at Goldendale, Washington, to systematically study the effect of vortex generators (VG's) on power performance. The subject unit was first tested without VG's to obtain baseline data. Vortex generators were then installed on the mid-blade assemblies, and the resulting 70% VG configuration was tested. Finally, vortex generators were mounted on the tip assemblies, and data was recorded for the 100% VG configuration. This test program and its results are discussed in this paper. The development of vortex generators is also presented.
Development and testing of a source subsystem for the supporting development PMAD DC test bed
NASA Technical Reports Server (NTRS)
Button, Robert M.
1991-01-01
The supporting Development Power Management and Distribution (PMAD) DC Test Bed is described. Its benefits to the Space Station Freedom Electrical Power System design are discussed along with a short description of how the PMAD DC Test Bed was systematically integrated. The Source Subsystem of the PMAD DC Test Bed consisting of a Sequential Shunt Unit (SSU) and a Battery Charge/Discharge Unit (BCDU) is introduced. The SSU is described in detail and component level test data is presented. Next, the BCDU's operation and design is given along with component level test data. The Source Subsystem is then presented and early data given to demonstrate an effective subsystem design.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giovanni, D.V.; Carr, R.C.; Landham, E.C.
Two products of coal quality research at the Electric Power Research Institute TM (EPRI) are available for field evaluation: Coal Quality Impact Model (CQIM and Fireside Testing Guidelines (FIG). The CQIM is a computer program that may be tailored to simulate the performance characteristics of a coal-fired power plant. The FIG is a technical report that guides utilities in conducting field tests to gather performance data and quantify the technical and economic impacts of different coals. Moreover, the results from field tests may be utilized to validate and assess the applicability of the CQIM. Field tests were conducted at Mississippimore » Power Company`s Watson Unit 4 to evaluate the coal quality impacts of coal switching on boiler performance and emissions. Watson Unit 4 is a 255 MW (gross), opposed-wall, pulverized-coal-fired boiler manufactured by Riley Stoker Corporation and rated at 1,779,000 lb/hr steam flow at 1000{degrees}F superheat steam temperature and 2,500 psig. The unit is equipped with a cold-side electrostatic precipitator for particulate matter control. Comprehensive tests were conducted on all major equipment components, including the pulverizers, fans, combustion equipment, boiler heat transfer surfaces, air preheater, and electrostatic precipitator, for two coals. The CQIN4 was configured to predict the performance of the unit when burning each coal. The work was sponsored by EPRI, and Mississippi Power Company (MPC) was the host utility company. This report summarizes results from the field test program, including potential heat rate improvements that were identified, and the differences in unit operations and performance for the two coals. The results from the CQIM validation effort are also presented.« less
[Portable multi-purpose device for monitoring of physiological informations].
Tamura, T; Togawa, T
1983-05-01
Unconstrained system that measures physiological information as skin temperatures and heart rate per unit time of a human subject was developed. The system contained portable device included memory control unit, instrumentation unit, timer and batteries, read-out unit, test unit and verify unit. Total number of data and channels, and interval were selected by switches in the memory control unit. The data from the instrumentation unit were transferred to memory control unit and stored in the Erasable Programmable ROM (EPROM). After measurement, EPROM chip was taken off the memory control unit and put on the read-out unit which transferred the data to the microcomputer. The data were directly calculated and analyzed by microcomputer. In application of the instrumentation unit, 8-channel skin thermometer was developed and tested. After amplification, 8 analog signals were multiplexed and converted into the binary codes. The digital signals were sequentially transferred to memory control unit and stored in the EPROM under controlled signal. The accuracy of the system is determined primarily by the accuracy of the sensor of instrumentation unit. The overall accuracy of 8-channel skin thermometer is conservatively stated within 0.1 degree C. This may prove to be useful in providing an objective measurement of human subjects, and can be used in studying environmental effect for human body and sport activities in a large population setting.
Aetiology of obstructive azoospermia in Chinese infertility patients.
Han, H; Liu, S; Zhou, X-G; Tian, L; Zhang, X-D
2016-09-01
To explore the aetiology of obstructive azoospermia (OA) in Chinese infertility patients, 133 OA patients was included in this study diagnosed and evaluated by one major specialist trained urological infertility. We retrospected the medical records to collect relative information. All of the patients had been underwent physical examination, ultrasound scan to the urogenital system, serum hormone tests, genetic tests and two separate semen analyses. The mean age of all 133 patients was 32.7 ± 6.8 years. A total of 266 reproductive tract units (two/patient) were classified into four categories: no causes (Idiopathic) for 74 units (27.8%), single cause for 173 units (65.0%), double causes for 17 units (6.4%) and triple causes for two units (0.8%). As to single cause of OA, there were four types: trauma for 0 unit (0%), infection for 125 units (47.0%), dysplasia for 11 units (4.1%) and surgeries for 37 units (13.9%). As to total cause of OA, there were five types: infection for 144 units (54.1%), orchitis for 51 units (19.2%), epididymitis for 54 units (20.3%), gonorrhoea for 28 units (10.5%) and inguinal hernia repair surgery for 18 units (6.8%). The most frequent cause of obstructive azoospermia was infection revealed in these Chinese infertility populations, followed by idiopathic reason. © 2015 Blackwell Verlag GmbH.
Cold-end Subsystem Testing for the Fission Power System Technology Demonstration Unit
NASA Technical Reports Server (NTRS)
Briggs, Maxwell; Gibson, Marc; Ellis, David; Sanzi, James
2013-01-01
The Fission Power System (FPS) Technology Demonstration Unit (TDU) consists of a pumped sodium-potassium (NaK) loop that provides heat to a Stirling Power Conversion Unit (PCU), which converts some of that heat into electricity and rejects the waste heat to a pumped water loop. Each of the TDU subsystems is being tested independently prior to full system testing at the NASA Glenn Research Center. The pumped NaK loop is being tested at NASA Marshall Space Flight Center; the Stirling PCU and electrical controller are being tested by Sunpower Inc.; and the pumped water loop is being tested at Glenn. This paper describes cold-end subsystem setup and testing at Glenn. The TDU cold end has been assembled in Vacuum Facility 6 (VF 6) at Glenn, the same chamber that will be used for TDU testing. Cold-end testing in VF 6 will demonstrate functionality; validated cold-end fill, drain, and emergency backup systems; and generated pump performance and system pressure drop data used to validate models. In addition, a low-cost proof-of concept radiator has been built and tested at Glenn, validating the design and demonstrating the feasibility of using low-cost metal radiators as an alternative to high-cost composite radiators in an end-to-end TDU test.
Cold-End Subsystem Testing for the Fission Power System Technology Demonstration Unit
NASA Technical Reports Server (NTRS)
Briggs, Mazwell; Gibson, Marc; Ellis, David; Sanzi, James
2013-01-01
The Fission Power System (FPS) Technology Demonstration Unit (TDU) consists of a pumped sodiumpotassium (NaK) loop that provides heat to a Stirling Power Conversion Unit (PCU), which converts some of that heat into electricity and rejects the waste heat to a pumped water loop. Each of the TDU subsystems is being tested independently prior to full system testing at the NASA Glenn Research Center. The pumped NaK loop is being tested at NASA Marshall Space Flight Center; the Stirling PCU and electrical controller are being tested by Sunpower Inc.; and the pumped water loop is being tested at Glenn. This paper describes cold-end subsystem setup and testing at Glenn. The TDU cold end has been assembled in Vacuum Facility 6 (VF 6) at Glenn, the same chamber that will be used for TDU testing. Cold-end testing in VF 6 will demonstrate functionality; validated coldend fill, drain, and emergency backup systems; and generated pump performance and system pressure drop data used to validate models. In addition, a low-cost proof-of concept radiator has been built and tested at Glenn, validating the design and demonstrating the feasibility of using low-cost metal radiators as an alternative to highcost composite radiators in an end-to-end TDU test.
Development Status of the Fission Power System Technology Demonstration Unit
NASA Technical Reports Server (NTRS)
Briggs, Maxwell H.; Gibson, Marc A.; Geng, Steven M.; Pearson, Jon Boise; Godfoy, Thomas
2012-01-01
This paper summarizes the progress that has been made in the development of the Fission Power System Technology Demonstration Unit (TDU). The reactor simulator core and Annular Linear Induction Pump have been fabricated and assembled into a test loop at the NASA Marshall Space Flight Center. A 12 kWe Power Conversion Unit (PCU) is being developed consisting of two 6 kWe free-piston Stirling engines. The two 6 kWe engines have been fabricated by Sunpower Inc. and are currently being tested separately prior to integration into the PCU. The Facility Cooling System (FCS) used to reject convertor waste heat has been assembled and tested at the NASA Glenn Research Center (GRC). The structural elements, including a Buildup Assembly Platform (BAP) and Upper Truss Structure (UTS) have been fabricated, and will be used to test cold-end components in thermal vacuum prior to TDU testing. Once all components have been fully tested at the subsystem level, they will be assembled into an end-to-end system and tested in thermal vacuum at GRC.
Development Status of the Fission Power System Technology Demonstration Unit
NASA Technical Reports Server (NTRS)
Briggs, Maxwell H.; Gibson, Marc A.; Geng, Steven M; Pearson, Jon Boise; Godfroy, Thomas
2012-01-01
This paper summarizes the progress that has been made in the development of the Fission Power System Technology Demonstration Unit (TDU). The reactor simulator core and Annular Linear Induction Pump have been fabricated and assembled into a test loop at the NASA Marshall Space Flight Center. A 12 kWe Power Conversion Unit (PCU) is being developed consisting of two 6 kWe free-piston Stirling engines. The two 6 kWe engines have been fabricated by Sunpower Inc. and are currently being tested separately prior to integration into the PCU. The Facility Cooling System (FCS) used to reject convertor waste heat has been assembled and tested at the NASA Glenn Research Center (GRC). The structural elements, including a Buildup Assembly Platform (BAP) and Upper Truss Structure (UTS) have been fabricated, and will be used to test cold-end components in thermal vacuum prior to TDU testing. Once all components have been fully tested at the subsystem level, they will be assembled into an end-to-end system and tested in thermal vacuum at NASA GRC.
Field Tests of Wind Turbine Unit with Tandem Wind Rotors and Double Rotational Armatures
NASA Astrophysics Data System (ADS)
Galal, Ahmed Mohamed; Kanemoto, Toshiaki
This paper discusses the field tests of the wind turbine unit, in which the front and the rear wind rotors drive the inner and the outer armatures of the synchronous generator. The wind rotors were designed conveniently by the traditional procedure for the single wind rotor, where the diameters of the front and the rear wind rotors are 2 m and 1.33 m. The tests were done on a pick-up type truck driven straightly at constant speed. The rotational torque of the unit is directly proportional to the induced electric current irrespective of the rotational speeds of the wind rotors, while the induced voltage is proportional to the relative rotational speed. The performance of the unit is significantly affected not only by the wind velocity, but also by the blade setting angles of both wind rotors and the applied load especially at lower wind velocity.
Guidelines for testing and release procedures
NASA Technical Reports Server (NTRS)
Molari, R.; Conway, M.
1984-01-01
Guidelines and procedures are recommended for the testing and release of the types of computer software efforts commonly performed at NASA/Ames Research Center. All recommendations are based on the premise that testing and release activities must be specifically selected for the environment, size, and purpose of each individual software project. Guidelines are presented for building a Test Plan and using formal Test Plan and Test Care Inspections on it. Frequent references are made to NASA/Ames Guidelines for Software Inspections. Guidelines are presented for selecting an Overall Test Approach and for each of the four main phases of testing: (1) Unit Testing of Components, (2) Integration Testing of Components, (3) System Integration Testing, and (4) Acceptance Testing. Tools used for testing are listed, including those available from operating systems used at Ames, specialized tools which can be developed, unit test drivers, stub module generators, and the use of format test reporting schemes.
ERIC Educational Resources Information Center
Miyamoto, Kenichiro
2008-01-01
Every state in the United States, under the NCLB act, has set state standards and is testing all students in grades 3-8. Students are given printed questions to which they write answers with a pencil on an answer sheet. These written tests are usually given to determine the academic achievements of students. This paper traces the early history of…
NASA Technical Reports Server (NTRS)
Tobey, G. L.
1978-01-01
Tests were performed to evaluate the operating characteristics of the interface between the Space Lab Bus Interface Unit (SL/BIU) and the Orbiter Multiplexer-Demultiplexer (MDM) serial data input-output (SIO) module. This volume contains the test equipment preparation procedures and a detailed description of the Nova/Input Output Processor Simulator (IOPS) software used during the data transfer tests to determine word error rates (WER).
2014-03-14
NUMBER FA8201-09-D-0002 Overhaul Complex at Little Mountain Test Annex, Utah 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER Streamline Consulting, LLC 1713 N. Sweetwater Lane Farmington, Utah 84025...Hill Air Force Base (AFB) proposes to construct a new emergency power unit overhaul complex at Little Mountain Test Annex, Utah . Buildings 2005
Experimental Data for Two Different Alternator Configurations in a Solar Brayton Power System
NASA Technical Reports Server (NTRS)
Mason, Lee S.; Shaltens, Richard K.; Espinosa, William D.
1997-01-01
A solar dynamic (SD) space power system has been under test at the NASA Lewis Research Center since 1994. The SD Ground Test Demonstration (GTD) system includes a solar concentrator, heat receiver with thermal energy storage, Brayton power conversion unit, and radiator installed in a thermal-vacuum chamber with a solar simulator. The Brayton unit has been operated with two different turboalternator compressor (TAC) assemblies, one which included a Rice Lundell alternator and another which incorporated a permanent magnet (PM) alternator. The Rice alternator was part of the mini-Brayton rotating unit, designed and built during the 1970's and refurbished for the GTD. The PM TAC was a development unit from the Joint US/Russian SD Flight Project. This paper highlights the operational differences (and similarities) between the Rice and PM TAC configurations including a comparative evaluation of startup characteristics and operating performance. The two alternator configurations were tested under similar thermal conditions, as an interchangeable component within the SD system. The electrical characteristics of the two units, however, dictated the use of significantly different power conditioning and control strategies. The electrical control architectures are described and compared. Test data are presented on TAC startup and system operating performance for both configurations.
High Voltage Hall Accelerator Propulsion System Development for NASA Science Missions
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Haag, Thomas; Huang, Wensheng; Shastry, Rohit; Pinero, Luis; Peterson, Todd; Dankanich, John; Mathers, Alex
2013-01-01
NASA Science Mission Directorates In-Space Propulsion Technology Program is sponsoring the development of a 3.8 kW-class engineering development unit Hall thruster for implementation in NASA science and exploration missions. NASA Glenn Research Center and Aerojet are developing a high fidelity high voltage Hall accelerator (HiVHAc) thruster that can achieve specific impulse magnitudes greater than 2,700 seconds and xenon throughput capability in excess of 300 kilograms. Performance, plume mappings, thermal characterization, and vibration tests of the HiVHAc engineering development unit thruster have been performed. In addition, the HiVHAc project is also pursuing the development of a power processing unit (PPU) and xenon feed system (XFS) for integration with the HiVHAc engineering development unit thruster. Colorado Power Electronics and NASA Glenn Research Center have tested a brassboard PPU for more than 1,500 hours in a vacuum environment, and a new brassboard and engineering model PPU units are under development. VACCO Industries developed a xenon flow control module which has undergone qualification testing and will be integrated with the HiVHAc thruster extended duration tests. Finally, recent mission studies have shown that the HiVHAc propulsion system has sufficient performance for four Discovery- and two New Frontiers-class NASA design reference missions.
Age-related motor unit remodeling in the Tibialis Anterior.
Siddiqi, Ariba; Kumar, Dinesh; Arjunan, Sridhar
2015-01-01
Limited studies exist on the use of surface electromyogram (EMG) signal features to detect age-related motor unit remodeling in the Tibialis Anterior. Motor unit remodeling leads to declined muscle strength and force steadiness during submaximal contractions which are factors for risk of falls in the elderly. This study investigated the remodeling phenomena in the Tibialis Anterior using sample entropy and higher order statistics. Eighteen young (26.1 ± 2.9 years) and twelve elderly (68.7 ± 9.0 years) participants performed isometric dorsiflexion of the ankle at 20% maximal voluntary contraction (MVC) and their Tibialis Anterior (TA) EMG was recorded. Sample entropy, Gaussianity and Linearity Test statistics were calculated from the recorded EMG for each MVC. Shapiro-Wilk test was used to determine normality, and either a two-tail student t-test or Wilcoxon rank sum test was performed to determine significant difference in the EMG features between the young and old cohorts. Results show age-related motor unit remodeling to be depicted by decreased sample entropy (p <; 0.1), increased non-Gaussianity (p <; 0.05) and lesser degree of linearity in the elderly. This is due to the increased sparsity of the MUAPs as a result of the denervation-reinnervation process, and the decrease in total number of motor units.
NASA Astrophysics Data System (ADS)
Urbahs, A.; Urbaha, M.; Carjova, K.
2017-10-01
The theoretical calculation for development of planetary gear unit of wind turbine (WT) and its experimental tests are presented in the paper. Development of experimental prototypes from composite materials is essential to determine capability of element and its impact on feature. Two experimental scale prototypes of planetary gear unit for WT were developed for such purposes. Hall transducer, servomechanisms and optical tachometers were used to obtain results, comparison analysis of theoretical and actual data was performed as well as quality assessment of experimental prototypes of planetary gear unit. After kinematic and load analysis as well as control of rotation frequency, it is possible to declare that the unit is able to operate at designated quality. Theoretical calculations and test results obtained are used for industrial WT prototype development.
Gestational Trophoblastic Disease Diagnosis Delayed by the Hook Effect.
Cormano, Julia; Mackay, Gillian; Holschneider, Christine
2015-10-01
A "hook effect" resulting from saturation of antibodies used in pregnancy tests can occur at human chorionic gonadotropin (hCG) levels above 500,000 milliinternational units/mL, resulting in falsely negative values. A 34-year-old woman, gravida 5 para 3, presented to the emergency department after heavy bleeding. Ultrasonogram revealed a uterine mass, urine pregnancy test result was negative, and endometrial biopsy inconclusive. The patient was discharged and presented 10 days later with recurrent bleeding. Urine pregnancy test result was again negative, but serum hCG was 581 milliinternational units/mL. Serial dilution revealed an actual hCG higher than 5 million milliinternational units/mL. She was diagnosed with gestational trophoblastic disease. Awareness of the risk of a false-negative pregnancy test result when hCG levels are extremely high may prevent delayed diagnosis of gestational trophoblastic disease.
Sporicidal activity of a new low-temperature sterilization technology: the Sterrad 50 sterilizer.
Rutala, W A; Gergen, M F; Weber, D J
1999-07-01
This study was undertaken to evaluate the efficacy of a new low-temperature sterilization system that recently has been cleared by the Food and Drug Administration, the Sterrad 50. Flat stainless steel carriers were inoculated with approximately 10(6) Bacillus stearothermophilus spores. These carriers were placed aseptically in the middle of 40-cm-long stainless steel-lumened test units of varying diameters (1 mm, 2 mm, and 3 mm). After inoculation, the test units were processed in the Sterrad 50. After sterilization, the carriers were assayed for growth of the B. stearothermophilus spores. Our data demonstrated that the Sterrad 50 was highly effective in killing the B. stearothermophilus spores (no positive carriers with 30 tests of each lumen-diameter test unit). The Sterrad 50 is likely to be clinically useful for the sterilization of heat-sensitive medical equipment.
Increasing Inferential Leverage in the Comparative Method: Placebo Tests in Small-"n" Research
ERIC Educational Resources Information Center
Glynn, Adam N.; Ichino, Nahomi
2016-01-01
We delineate the underlying homogeneity assumption, procedural variants, and implications of the comparative method and distinguish this from Mill's method of difference. We demonstrate that additional units can provide "placebo" tests for the comparative method even if the scope of inference is limited to the two units under comparison.…
30 CFR 74.5 - Tests of coal mine dust personal sampler units.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Tests of coal mine dust personal sampler units. 74.5 Section 74.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH COAL MINE DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust...
30 CFR 74.5 - Tests of coal mine dust personal sampler units.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Tests of coal mine dust personal sampler units. 74.5 Section 74.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH COAL MINE DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust...
30 CFR 74.5 - Tests of coal mine dust personal sampler units.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tests of coal mine dust personal sampler units. 74.5 Section 74.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH COAL MINE DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust...
30 CFR 74.5 - Tests of coal mine dust personal sampler units.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Tests of coal mine dust personal sampler units. 74.5 Section 74.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH COAL MINE DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust...
Color Vision Deficiencies in Children. United States.
ERIC Educational Resources Information Center
National Center for Health Statistics (DHEW/PHS), Hyattsville, MD.
Presented are prevalence data on color vision deficiencies (color blindness) in noninstitutionalized children, aged 6-11, in the United States, as estimated from the Health Examination Survey findings on a representative sample of over 7,400 children. Described are the two color vision tests used in the survey, the Ishihara Test for Color…
The report gives results of the collection of emissions test data st two triethylene glycol units to provide data for the comparison to GRI-GLYCalc, a computer program developed to estimate emissions from glycol dehydrators. [NOTE: Glycol dehydrators are used in the natural gas i...
The report gives results of the collection of emissions tests data at two triethylene glycol units to provide data for comparison to GRI-GLYCalc, a computer program developed to estimate emissions from glycol dehydrators. (NOTE: Glycol dehydrators are used in the natural gas indu...
Year 6 Planning Exemplification 3. National Literacy Strategy.
ERIC Educational Resources Information Center
Department for Education and Skills, London (England).
Third in a series of booklets designed to assist Year 6 teachers with planning instruction to meet objectives of the National Literacy Strategy, this booklet contains Summer Term planning exemplification for three "revision" units (Narrative, Poetry and Non-fiction) prior to the Key Stage 2 tests and one unit after the tests (Extended…
Students' Illustrations of the Human Nervous System as a Formative Assessment Tool
ERIC Educational Resources Information Center
Ranaweera, Sisika Priyani Nelum; Montplaisir, Lisa Marie
2010-01-01
The purpose of this study was to explore students' knowledge and learning of the human nervous system (HNS) in an introductory undergraduate Human Anatomy and Physiology course. Classroom observations, demographic data, a preinstructional unit test with drawings, and a postinstructional unit test with drawings were used to identify students'…
40 CFR 63.865 - Performance test requirements and test methods.
Code of Federal Regulations, 2013 CFR
2013-07-01
... follows: ER18FE03.012 Where: ERSCCU = THC emission rate reported as carbon from each semichemical combustion unit, kg/Mg (lb/ton) of black liquor solids fired; THCmeas = Measured THC mass emission rate... semichemical combustion unit has selected the percentage reduction standards for THC, under § 63.862(c)(2)(ii...
40 CFR 63.865 - Performance test requirements and test methods.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Where: ERSCCU = THC emission rate reported as carbon from each semichemical combustion unit, kg/Mg (lb/ton) of black liquor solids fired; THCmeas = Measured THC mass emission rate reported as carbon, kg/hr... unit has selected the percentage reduction standards for THC, under § 63.862(c)(2)(ii), the percentage...
40 CFR 63.865 - Performance test requirements and test methods.
Code of Federal Regulations, 2012 CFR
2012-07-01
... follows: ER18FE03.012 Where: ERSCCU = THC emission rate reported as carbon from each semichemical combustion unit, kg/Mg (lb/ton) of black liquor solids fired; THCmeas = Measured THC mass emission rate... semichemical combustion unit has selected the percentage reduction standards for THC, under § 63.862(c)(2)(ii...
21 CFR 640.15 - Segments for testing.
Code of Federal Regulations, 2014 CFR
2014-04-01
... cells. (c) All segments accompanying a unit of Red Blood Cells shall be filled at the time the blood is... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.15 Segments for testing... provided with each unit of Whole Blood or Red Blood Cells when issued or reissued. (b) Before they are...
21 CFR 640.15 - Segments for testing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... cells. (c) All segments accompanying a unit of Red Blood Cells shall be filled at the time the blood is... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.15 Segments for testing... provided with each unit of Whole Blood or Red Blood Cells when issued or reissued. (b) Before they are...
21 CFR 640.15 - Segments for testing.
Code of Federal Regulations, 2013 CFR
2013-04-01
... cells. (c) All segments accompanying a unit of Red Blood Cells shall be filled at the time the blood is... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.15 Segments for testing... provided with each unit of Whole Blood or Red Blood Cells when issued or reissued. (b) Before they are...
21 CFR 640.15 - Segments for testing.
Code of Federal Regulations, 2012 CFR
2012-04-01
... cells. (c) All segments accompanying a unit of Red Blood Cells shall be filled at the time the blood is... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.15 Segments for testing... provided with each unit of Whole Blood or Red Blood Cells when issued or reissued. (b) Before they are...
Engineering Encounters: Sailing into the Digital Era
ERIC Educational Resources Information Center
Bellavance, Janet; Truchon, Amy
2015-01-01
This article describes how Janet Bellavance teamed with technology integration specialist, Amy Truchon to incorporate iPads into her Engineering is Elementary (EiE) unit--a curriculum that engages elementary students in engineering simple technologies. In an EiE unit, students design, test, and then, based on test results, improve their design,…
21 CFR 640.15 - Segments for testing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.15 Segments for testing... provided with each unit of Whole Blood or Red Blood Cells when issued or reissued. (b) Before they are... cells. (c) All segments accompanying a unit of Red Blood Cells shall be filled at the time the blood is...
Comparing Standard Deviation Effects across Contexts
ERIC Educational Resources Information Center
Ost, Ben; Gangopadhyaya, Anuj; Schiman, Jeffrey C.
2017-01-01
Studies using tests scores as the dependent variable often report point estimates in student standard deviation units. We note that a standard deviation is not a standard unit of measurement since the distribution of test scores can vary across contexts. As such, researchers should be cautious when interpreting differences in the numerical size of…
DOE Office of Scientific and Technical Information (OSTI.GOV)
George, James T.; Sobolik, Steven R.; Lee, Moo Y.
The study described in this report involves heated and unheated pressurized slot testing to determine thermo-mechanical properties of the Tptpll (Tertiary, Paintbrush, Topopah Spring Tuff Formation, crystal poor, lower lithophysal) and Tptpul (upper lithophysal) lithostratigraphic units at Yucca Mountain, Nevada. A large volume fraction of the proposed repository at Yucca Mountain may reside in the Tptpll lithostratigraphic unit. This unit is characterized by voids, or lithophysae, which range in size from centimeters to meters, making a field program an effective method of measuring bulk thermal-mechanical rock properties (thermal expansion, rock mass modulus, compressive strength, time-dependent deformation) over a range ofmore » temperature and rock conditions. The field tests outlined in this report provide data for the determination of thermo-mechanical properties of this unit. Rock-mass response data collected during this field test will reduce the uncertainty in key thermal-mechanical modeling parameters (rock-mass modulus, strength and thermal expansion) for the Tptpll lithostratigraphic unit, and provide a basis for understanding thermal-mechanical behavior of this unit. The measurements will be used to evaluate numerical models of the thermal-mechanical response of the repository. These numerical models are then used to predict pre- and post-closure repository response. ACKNOWLEDGEMENTS The authors would like to thank David Bronowski, Ronnie Taylor, Ray E. Finley, Cliff Howard, Michael Schuhen (all SNL) and Fred Homuth (LANL) for their work in the planning and implementation of the tests described in this report. This is a reprint of SAND2004-2703, which was originally printed in July 2004. At that time, it was printed for a restricted audience. It has now been approved for unlimited release.« less
Bergeron, V; Reboux, G; Poirot, J L; Laudinet, N
2007-10-01
To evaluate the performance of a new mobile air-treatment unit that uses nonthermal-plasma reactors for lowering the airborne bioburden in critical hospital environments and reducing the risk of nosocomial infection due to opportunistic airborne pathogens, such as Aspergillus fumigatus. Tests were conducted in 2 different high-risk hospital areas: an operating room under simulated conditions and rooms hosting patients in a pediatric hematology ward. Operating room testing provided performance evaluations of removal rates for airborne contamination (ie, particles larger than 0.5 microm) and overall lowering of the airborne bioburden (ie, colony-forming units of total mesophilic flora and fungal flora per cubic meter of air). In the hematology service, opportunistic and nonpathogenic airborne fungal levels in a patient's room equipped with an air-treatment unit were compared to those in a control room. In an operating room with a volume of 118 m(3), the time required to lower the concentration of airborne particles larger than 0.5 microm by 90% was decreased from 12 minutes with the existing high-efficiency particulate air filtration system to less than 2 minutes with the units tested, with a 2-log decrease in the steady-state levels of such particles (P<.01). Concurrently, total airborne mesophilic flora concentrations dropped by a factor of 2, and the concentrations of fungal species were reduced to undetectable levels (P<.01). The 12-day test period in the hematology ward revealed a significant reduction in airborne fungus levels (P<.01), with average reductions of 75% for opportunistic species and 82% for nonpathogenic species. Our data indicate that the mobile, nonthermal-plasma air treatment unit tested in this study can rapidly reduce the levels of airborne particles and significantly lower the airborne bioburden in high-risk hospital environments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Tengfang
2006-10-20
Lawrence Berkeley National Laboratory (LBNL) is now finalizing the Phase 2 Research and Demonstration Project on characterizing 2-foot x 4-foot (61-cm x 122-cm) fan-filter units in the market using the first-ever standard laboratory test method developed at LBNL.[1][2][3] Fan-filter units deliver re-circulated air and provide particle filtration control for clean environments. Much of the energy in cleanrooms (and minienvironments) is consumed by 2-foot x 4-foot (61-cm x 122-cm) or 4-foot x 4-foot (122-cm x 122-cm) fan-filter units that are typically located in the ceiling (25-100% coverage) of cleanroom controlled environments. Thanks to funding support by the California Energy Commission's Industrialmore » Program of the Public Interest Energy Research (PIER) Program, and significant participation from manufacturers and users of fan-filter units from around the world, LBNL has developed and performed a series of standard laboratory tests and reporting on a variety of 2-foot x 4-foot (61-cm x 122-cm) fan-filter units (FFUs). Standard laboratory testing reports have been completed and reported back to anonymous individual participants in this project. To date, such reports on standard testing of FFU performance have provided rigorous and useful data for suppliers and end users to better understand, and more importantly, to quantitatively characterize performance of FFU products under a variety of operating conditions.[1] In the course of the project, the standard laboratory method previously developed at LBNL has been under continuous evaluation and update.[2][3] Based upon the updated standard, it becomes feasible for users and suppliers to characterize and evaluate energy performance of FFUs in a consistent way.« less