Burnstein, Bryan D; Steele, Russell J; Shrier, Ian
2011-01-01
Fitness testing is used frequently in many areas of physical activity, but the reliability of these measurements under real-world, practical conditions is unknown. To evaluate the reliability of specific fitness tests using the methods and time periods used in the context of real-world sport and occupational management. Cohort study. Eighteen different Cirque du Soleil shows. Cirque du Soleil physical performers who completed 4 consecutive tests (6-month intervals) and were free of injury or illness at each session (n = 238 of 701 physical performers). Performers completed 6 fitness tests on each assessment date: dynamic balance, Harvard step test, handgrip, vertical jump, pull-ups, and 60-second jump test. We calculated the intraclass coefficient (ICC) and limits of agreement between baseline and each time point and the ICC over all 4 time points combined. Reliability was acceptable (ICC > 0.6) over an 18-month time period for all pairwise comparisons and all time points together for the handgrip, vertical jump, and pull-up assessments. The Harvard step test and 60-second jump test had poor reliability (ICC < 0.6) between baseline and other time points. When we excluded the baseline data and calculated the ICC for 6-month, 12-month, and 18-month time points, both the Harvard step test and 60-second jump test demonstrated acceptable reliability. Dynamic balance was unreliable in all contexts. Limit-of-agreement analysis demonstrated considerable intraindividual variability for some tests and a learning effect by administrators on others. Five of the 6 tests in this battery had acceptable reliability over an 18-month time frame, but the values for certain individuals may vary considerably from time to time for some tests. Specific tests may require a learning period for administrators.
Burnstein, Bryan D.; Steele, Russell J.; Shrier, Ian
2011-01-01
Context: Fitness testing is used frequently in many areas of physical activity, but the reliability of these measurements under real-world, practical conditions is unknown. Objective: To evaluate the reliability of specific fitness tests using the methods and time periods used in the context of real-world sport and occupational management. Design: Cohort study. Setting: Eighteen different Cirque du Soleil shows. Patients or Other Participants: Cirque du Soleil physical performers who completed 4 consecutive tests (6-month intervals) and were free of injury or illness at each session (n = 238 of 701 physical performers). Intervention(s): Performers completed 6 fitness tests on each assessment date: dynamic balance, Harvard step test, handgrip, vertical jump, pull-ups, and 60-second jump test. Main Outcome Measure(s): We calculated the intraclass coefficient (ICC) and limits of agreement between baseline and each time point and the ICC over all 4 time points combined. Results: Reliability was acceptable (ICC > 0.6) over an 18-month time period for all pairwise comparisons and all time points together for the handgrip, vertical jump, and pull-up assessments. The Harvard step test and 60-second jump test had poor reliability (ICC < 0.6) between baseline and other time points. When we excluded the baseline data and calculated the ICC for 6-month, 12-month, and 18-month time points, both the Harvard step test and 60-second jump test demonstrated acceptable reliability. Dynamic balance was unreliable in all contexts. Limit-of-agreement analysis demonstrated considerable intraindividual variability for some tests and a learning effect by administrators on others. Conclusions: Five of the 6 tests in this battery had acceptable reliability over an 18-month time frame, but the values for certain individuals may vary considerably from time to time for some tests. Specific tests may require a learning period for administrators. PMID:22488138
Point-of-care D-dimer testing in emergency departments.
Marquardt, Udo; Apau, Daniel
2015-09-01
Overcrowding and prolonged patient stays in emergency departments (EDs) affect patients' experiences and outcomes, and increase healthcare costs. One way of addressing these problems is through using point-of-care blood tests, laboratory testing undertaken near patient locations with rapidly available results. D-dimer tests are used to exclude venous thromboembolism (VTE), a common presentation in EDs, in low-risk patients. However, data on the effects of point-of-care D-dimer testing in EDs and other urgent care settings are scarce. This article reports the results of a literature review that examined the benefits to patients of point-of-care D-dimer testing in terms of reduced turnaround times (time to results), and time to diagnosis, discharge or referral. It also considers the benefits to organisations in relation to reduced ED crowding and increased cost effectiveness. The review concludes that undertaking point-of-care D-dimer tests, combined with pre-test probability scores, can be a quick and safe way of ruling out VTE and improving patients' experience.
Normalization methods in time series of platelet function assays
Van Poucke, Sven; Zhang, Zhongheng; Roest, Mark; Vukicevic, Milan; Beran, Maud; Lauwereins, Bart; Zheng, Ming-Hua; Henskens, Yvonne; Lancé, Marcus; Marcus, Abraham
2016-01-01
Abstract Platelet function can be quantitatively assessed by specific assays such as light-transmission aggregometry, multiple-electrode aggregometry measuring the response to adenosine diphosphate (ADP), arachidonic acid, collagen, and thrombin-receptor activating peptide and viscoelastic tests such as rotational thromboelastometry (ROTEM). The task of extracting meaningful statistical and clinical information from high-dimensional data spaces in temporal multivariate clinical data represented in multivariate time series is complex. Building insightful visualizations for multivariate time series demands adequate usage of normalization techniques. In this article, various methods for data normalization (z-transformation, range transformation, proportion transformation, and interquartile range) are presented and visualized discussing the most suited approach for platelet function data series. Normalization was calculated per assay (test) for all time points and per time point for all tests. Interquartile range, range transformation, and z-transformation demonstrated the correlation as calculated by the Spearman correlation test, when normalized per assay (test) for all time points. When normalizing per time point for all tests, no correlation could be abstracted from the charts as was the case when using all data as 1 dataset for normalization. PMID:27428217
Jerosch-Herold, Christina
2003-06-01
A longitudinal dynamic cohort study was conducted on patients with median nerve injuries to evaluate the relative responsiveness of five sensibility tests: touch threshold using the WEST (monofilaments), static two-point discrimination, locognosia, a pick-up test and an object recognition test. Repeated assessments were performed starting at 6 months after surgery. In order to compare the relative responsiveness of each test, effect size and the standard response mean were calculated for sensibility changes occurring between 6 and 18 months after repair. Large effect sizes (>0.8) and standard response means (>0.8) were obtained for the WEST, locognosia, pick-up and object recognition tests. Two-point discrimination was hardly measurable at any time point and exhibited strong flooring effects. Further analysis of all time points was undertaken to assess the strength of the monotonic relationship between test scores and time elapsed since surgery. Comparison of monotonicity between the five tests indicated that the WEST performed best, whereas two-point discrimination performed worst. These results suggest that the monofilament test (WEST), locognosia test, Moberg pick-up test and tactile gnosis test capture sensibility changes over time well and should be considered for inclusion in the outcome assessment of patients with median nerve injury.
Common pitfalls in statistical analysis: The perils of multiple testing
Ranganathan, Priya; Pramesh, C. S.; Buyse, Marc
2016-01-01
Multiple testing refers to situations where a dataset is subjected to statistical testing multiple times - either at multiple time-points or through multiple subgroups or for multiple end-points. This amplifies the probability of a false-positive finding. In this article, we look at the consequences of multiple testing and explore various methods to deal with this issue. PMID:27141478
Analysis of EUVE Experiment Results
NASA Technical Reports Server (NTRS)
Horan, Stephen
1996-01-01
A series of tests to validate an antenna pointing concept for spin-stabilized satellites using a data relay satellite are described. These tests show that proper antenna pointing on an inertially-stabilized spacecraft can lead to significant access time through the relay satellite even without active antenna pointing. We summarize the test results, the simulations to model the effects of antenna pattern and space loss, and the expected contact times. We also show how antenna beam width affects the results.
Test-retest reliability of the irrational performance beliefs inventory.
Turner, M J; Slater, M J; Dixon, J; Miller, A
2018-02-01
The irrational performance beliefs inventory (iPBI) was developed to measure irrational beliefs within performance domains such as sport, academia, business, and the military. Past research indicates that the iPBI has good construct, concurrent, and predictive validity, but the test-retest reliability of the iPBI has not yet been examined. Therefore, in the present study the iPBI was administered to university sport and exercise students (n = 160) and academy soccer athletes (n = 75) at three-time points. Time point two occurred 7 days after time point one, and time point three occurred 21 days after time point two. In addition, social desirability was also measured. Repeated-measures MANCOVAs, intra-class coefficients, and Pearson's (r) correlations demonstrate that the iPBI has good test-retest reliability, with iPBI scores remaining stable across the three-time points. Pearson's correlation coefficients revealed no relationships between the iPBI and social desirability, indicating that the iPBI is not highly susceptible to response bias. The results are discussed with reference to the continued usage and development of the iPBI, and future research recommendations relating to the investigation of irrational performance beliefs are proposed.
Pérez, Teresa; Makrestsov, Nikita; Garatt, John; Torlakovic, Emina; Gilks, C Blake; Mallett, Susan
The Canadian Immunohistochemistry Quality Control program monitors clinical laboratory performance for estrogen receptor and progesterone receptor tests used in breast cancer treatment management in Canada. Current methods assess sensitivity and specificity at each time point, compared with a reference standard. We investigate alternative performance analysis methods to enhance the quality assessment. We used 3 methods of analysis: meta-analysis of sensitivity and specificity of each laboratory across all time points; sensitivity and specificity at each time point for each laboratory; and fitting models for repeated measurements to examine differences between laboratories adjusted by test and time point. Results show 88 laboratories participated in quality control at up to 13 time points using typically 37 to 54 histology samples. In meta-analysis across all time points no laboratories have sensitivity or specificity below 80%. Current methods, presenting sensitivity and specificity separately for each run, result in wide 95% confidence intervals, typically spanning 15% to 30%. Models of a single diagnostic outcome demonstrated that 82% to 100% of laboratories had no difference to reference standard for estrogen receptor and 75% to 100% for progesterone receptor, with the exception of 1 progesterone receptor run. Laboratories with significant differences to reference standard identified with Generalized Estimating Equation modeling also have reduced performance by meta-analysis across all time points. The Canadian Immunohistochemistry Quality Control program has a good design, and with this modeling approach has sufficient precision to measure performance at each time point and allow laboratories with a significantly lower performance to be targeted for advice.
[Automated analyzer of enzyme immunoassay].
Osawa, S
1995-09-01
Automated analyzers for enzyme immunoassay can be classified by several points of view: the kind of labeled antibodies or enzymes, detection methods, the number of tests per unit time, analytical time and speed per run. In practice, it is important for us consider the several points such as detection limits, the number of tests per unit time, analytical range, and precision. Most of the automated analyzers on the market can randomly access and measure samples. I will describe the recent advance of automated analyzers reviewing their labeling antibodies and enzymes, the detection methods, the number of test per unit time and analytical time and speed per test.
Genoway, Shyla; Caine, Vera; Singh, Ameeta E; Estefan, Andrew
2016-01-01
With a call to increase the accessibility of HIV testing, point-of-care testing for HIV is being readily adopted, but little attention has been paid to the experiences of people being tested at HIV point-of-care sites. Some testing environments, such as bathhouses, promote testing for HIV in higher-risk groups. In this narrative inquiry study we explored the experiences of people testing positive for HIV through point-of-care while at a bathhouse. Three narrative threads for reconsidering the practice were identified: (a) seeing complexities, understanding testing decisions in relation to time, place, and social context; (b) recognizing the impact and significance of secret and silent stories; and (c) tentative and tension-filled connections to care. It is important to understand testing experiences across time, place, and in diverse social contexts. These experiences are embedded within the larger life histories of people and raise questions about adequate support, follow-up, and counseling. Copyright © 2016 Association of Nurses in AIDS Care. Published by Elsevier Inc. All rights reserved.
Natoli, Lisa; Guy, Rebecca J; Shephard, Mark; Causer, Louise; Badman, Steven G; Hengel, Belinda; Tangey, Annie; Ward, James; Coburn, Tony; Anderson, David; Kaldor, John; Maher, Lisa
2015-01-01
Point-of-care tests for chlamydia (CT) and gonorrhoea (NG) could increase the uptake and timeliness of testing and treatment, contribute to improved disease control and reduce reproductive morbidity. The GeneXpert (Xpert CT/NG assay), suited to use at the point-of-care, is being used in the TTANGO randomised controlled trial (RCT) in 12 remote Australian health services with a high burden of sexually transmissible infections (STIs). This represents the first ever routine use of a molecular point-of-care diagnostic for STIs in primary care. The purpose of this study was to explore the acceptability of the GeneXpert to primary care staff in remote Australia. In-depth qualitative interviews were conducted with 16 staff (registered or enrolled nurses and Aboriginal Health Workers/Practitioners) trained and experienced with GeneXpert testing. Interviews were digitally-recorded and transcribed verbatim prior to content analysis. Most participants displayed positive attitudes, indicating the test was both easy to use and useful in their clinical context. Participants indicated that point-of-care testing had improved management of STIs, resulting in more timely and targeted treatment, earlier commencement of partner notification, and reduced follow up efforts associated with client recall. Staff expressed confidence in point-of-care test results and treating patients on this basis, and reported greater job satisfaction. While point-of-care testing did not negatively impact on client flow, several found the manual documentation processes time consuming, suggesting that improved electronic connectivity and test result transfer between the GeneXpert and patient management systems could overcome this. Managing positive test results in a shorter time frame was challenging for some but most found it satisfying to complete episodes of care more quickly. In the context of a RCT, health professionals working in remote primary care in Australia found the GeneXpert highly acceptable. These findings have implications for use in other primary care settings around the world.
A New Test Unit for Disintegration End-Point Determination of Orodispersible Films.
Low, Ariana; Kok, Si Ling; Khong, Yuet Mei; Chan, Sui Yung; Gokhale, Rajeev
2015-11-01
No standard time or pharmacopoeia disintegration test method for orodispersible films (ODFs) exists. The USP disintegration test for tablets and capsules poses significant challenges for end-point determination when used for ODFs. We tested a newly developed disintegration test unit (DTU) against the USP disintegration test. The DTU is an accessory to the USP disintegration apparatus. It holds the ODF in a horizontal position, allowing top-view of the ODF during testing. A Gauge R&R study was conducted to assign relative contributions of the total variability from the operator, sample or the experimental set-up. Precision was compared using commercial ODF products in different media. Agreement between the two measurement methods was analysed. The DTU showed improved repeatability and reproducibility compared to the USP disintegration system with tighter standard deviations regardless of operator or medium. There is good agreement between the two methods, with the USP disintegration test giving generally longer disintegration times possibly due to difficulty in end-point determination. The DTU provided clear end-point determination and is suitable for quality control of ODFs during product developmental stage or manufacturing. This may facilitate the development of a standardized methodology for disintegration time determination of ODFs. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.
van Maanen, Leendert; de Jong, Ritske; van Rijn, Hedderik
2014-01-01
When multiple strategies can be used to solve a type of problem, the observed response time distributions are often mixtures of multiple underlying base distributions each representing one of these strategies. For the case of two possible strategies, the observed response time distributions obey the fixed-point property. That is, there exists one reaction time that has the same probability of being observed irrespective of the actual mixture proportion of each strategy. In this paper we discuss how to compute this fixed-point, and how to statistically assess the probability that indeed the observed response times are generated by two competing strategies. Accompanying this paper is a free R package that can be used to compute and test the presence or absence of the fixed-point property in response time data, allowing for easy to use tests of strategic behavior. PMID:25170893
Test-Retest Reliability of the Short-Form Survivor Unmet Needs Survey.
Taylor, Karen; Bulsara, Max; Monterosso, Leanne
2018-01-01
Reliable and valid needs assessment measures are important assessment tools in cancer survivorship care. A new 30-item short-form version of the Survivor Unmet Needs Survey (SF-SUNS) was developed and validated with cancer survivors, including hematology cancer survivors; however, test-retest reliability has not been established. The objective of this study was to assess the test-retest reliability of the SF-SUNS with a cohort of lymphoma survivors ( n = 40). Test-retest reliability of the SF-SUNS was conducted at two time points: baseline (time 1) and 5 days later (time 2). Test-retest data were collected from lymphoma cancer survivors ( n = 40) in a large tertiary cancer center in Western Australia. Intraclass correlation analyses compared data at time 1 (baseline) and time 2 (5 days later). Cronbach's alpha analyses were performed to assess the internal consistency at both time points. The majority (23/30, 77%) of items achieved test-retest reliability scores 0.45-0.74 (fair to good). A high degree of overall internal consistency was demonstrated (time 1 = 0.92, time 2 = 0.95), with scores 0.65-0.94 across subscales for both time points. Mixed test-retest reliability of the SF-SUNS was established. Our results indicate the SF-SUNS is responsive to the changing needs of lymphoma cancer survivors. Routine use of cancer survivorship specific needs-based assessments is required in oncology care today. Nurses are well placed to administer these assessments and provide tailored information and resources. Further assessment of test-retest reliability in hematology and other cancer cohorts is warranted.
40 CFR 797.1330 - Daphnid chronic toxicity test.
Code of Federal Regulations, 2010 CFR
2010-07-01
... an extended period of time. In this test guideline, mortality and reproduction (and optionally... exposure over a specified period of time. In this guideline, the effect measured is immobilization. (4..., wet weight) to the volume (liters) of test solution in a test chamber at a point in time or passing...
40 CFR 797.1330 - Daphnid chronic toxicity test.
Code of Federal Regulations, 2013 CFR
2013-07-01
... an extended period of time. In this test guideline, mortality and reproduction (and optionally... exposure over a specified period of time. In this guideline, the effect measured is immobilization. (4..., wet weight) to the volume (liters) of test solution in a test chamber at a point in time or passing...
40 CFR 797.1330 - Daphnid chronic toxicity test.
Code of Federal Regulations, 2014 CFR
2014-07-01
... an extended period of time. In this test guideline, mortality and reproduction (and optionally... exposure over a specified period of time. In this guideline, the effect measured is immobilization. (4..., wet weight) to the volume (liters) of test solution in a test chamber at a point in time or passing...
40 CFR 797.1330 - Daphnid chronic toxicity test.
Code of Federal Regulations, 2011 CFR
2011-07-01
... an extended period of time. In this test guideline, mortality and reproduction (and optionally... exposure over a specified period of time. In this guideline, the effect measured is immobilization. (4..., wet weight) to the volume (liters) of test solution in a test chamber at a point in time or passing...
40 CFR 797.1330 - Daphnid chronic toxicity test.
Code of Federal Regulations, 2012 CFR
2012-07-01
... an extended period of time. In this test guideline, mortality and reproduction (and optionally... exposure over a specified period of time. In this guideline, the effect measured is immobilization. (4..., wet weight) to the volume (liters) of test solution in a test chamber at a point in time or passing...
Functional Test on (TES) Thermal Enclosure System
NASA Technical Reports Server (NTRS)
1992-01-01
MSFC Test Engineer performing a functional test on the TES. The TES can be operated as a refrigerator, with a minimum set point temperature of 4.0 degrees C, or as an incubator, with a maximum set point temperature 40.0 degrees C of the set point. The TES can be set to maintain a constant temperature or programmed to change temperature settings over time, internal temperature recorded by a date logger.
Variance change point detection for fractional Brownian motion based on the likelihood ratio test
NASA Astrophysics Data System (ADS)
Kucharczyk, Daniel; Wyłomańska, Agnieszka; Sikora, Grzegorz
2018-01-01
Fractional Brownian motion is one of the main stochastic processes used for describing the long-range dependence phenomenon for self-similar processes. It appears that for many real time series, characteristics of the data change significantly over time. Such behaviour one can observe in many applications, including physical and biological experiments. In this paper, we present a new technique for the critical change point detection for cases where the data under consideration are driven by fractional Brownian motion with a time-changed diffusion coefficient. The proposed methodology is based on the likelihood ratio approach and represents an extension of a similar methodology used for Brownian motion, the process with independent increments. Here, we also propose a statistical test for testing the significance of the estimated critical point. In addition to that, an extensive simulation study is provided to test the performance of the proposed method.
NASA Technical Reports Server (NTRS)
Laub, Bernard; Grinstead, Jay; Dyakonov, Artem; Venkatapathy, Ethiraj
2011-01-01
Though arc jet testing has been the proven method employed for development testing and certification of TPS and TPS instrumentation, the operational aspects of arc jets limit testing to selected, but constant, conditions. Flight, on the other hand, produces timevarying entry conditions in which the heat flux increases, peaks, and recedes as a vehicle descends through an atmosphere. As a result, we are unable to "test as we fly." Attempts to replicate the time-dependent aerothermal environment of atmospheric entry by varying the arc jet facility operating conditions during a test have proven to be difficult, expensive, and only partially successful. A promising alternative is to rotate the test model exposed to a constant-condition arc jet flow to yield a time-varying test condition at a point on a test article (Fig. 1). The model shape and rotation rate can be engineered so that the heat flux at a point on the model replicates the predicted profile for a particular point on a flight vehicle. This simple concept will enable, for example, calibration of the TPS sensors on the Mars Science Laboratory (MSL) aeroshell for anticipated flight environments.
40 CFR 86.1333 - Transient test cycle generation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... zero percent speeds, zero percent torque points, but may be engaged up to two points preceding a non-zero point, and may be engaged for time segments with zero percent speed and torque points of durations...
Low, Ariana; Kok, Si Ling; Khong, Yuetmei; Chan, Sui Yung; Gokhale, Rajeev
2015-11-01
No standard time or pharmacopoeia disintegration test method for orodispersible films (ODFs) exists. The USP disintegration test for tablets and capsules poses significant challenges for end-point determination when used for ODFs. We tested a newly developed disintegration test unit (DTU) against the USP disintegration test. The DTU is an accessory to the USP disintegration apparatus. It holds the ODF in a horizontal position, allowing top-view of the ODF during testing. A Gauge R&R study was conducted to assign relative contributions of the total variability from the operator, sample or the experimental set-up. Precision was compared using commercial ODF products in different media. Agreement between the two measurement methods was analysed. The DTU showed improved repeatability and reproducibility compared to the USP disintegration system with tighter standard deviations regardless of operator or medium. There is good agreement between the two methods, with the USP disintegration test giving generally longer disintegration times possibly due to difficulty in end-point determination. The DTU provided clear end-point determination and is suitable for quality control of ODFs during product developmental stage or manufacturing. This may facilitate the development of a standardized methodology for disintegration time determination of ODFs. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 104:3893-3903, 2015. Copyright © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.
Comparative study on novel test systems to determine disintegration time of orodispersible films.
Preis, Maren; Gronkowsky, Dorothee; Grytzan, Dominik; Breitkreutz, Jörg
2014-08-01
Orodispersible films (ODFs) are a promising innovative dosage form enabling drug administration without the need for water and minimizing danger of aspiration due to their fast disintegration in small amounts of liquid. This study focuses on the development of a disintegration test system for ODFs. Two systems were developed and investigated: one provides an electronic end-point, and the other shows a transferable setup of the existing disintegration tester for orodispersible tablets. Different ODF preparations were investigated to determine the suitability of the disintegration test systems. The use of different test media and the impact of different storage conditions of ODFs on their disintegration time were additionally investigated. The experiments showed acceptable reproducibility (low deviations within sample replicates due to a clear determination of the measurement end-point). High temperatures and high humidity affected some of the investigated ODFs, resulting in higher disintegration time or even no disintegration within the tested time period. The methods provided clear end-point detection and were applicable for different types of ODFs. By the modification of a conventional test system to enable application for films, a standard method could be presented to ensure uniformity in current quality control settings. © 2014 Royal Pharmaceutical Society.
ERIC Educational Resources Information Center
Thum, Yeow Meng; Bhattacharya, Suman Kumar
To better describe individual behavior within a system, this paper uses a sample of longitudinal test scores from a large urban school system to consider hierarchical Bayes estimation of a multilevel linear regression model in which each individual regression slope of test score on time switches at some unknown point in time, "kj."…
Stieger, Stefan; Gumhalter, Nora; Tran, Ulrich S.; Voracek, Martin; Swami, Viren
2013-01-01
The present study utilized a repeated cross-sectional survey design to examine belief in conspiracy theories about the abduction of Natascha Kampusch. At two time points (October 2009 and October 2011), participants drawn from independent cross-sections of the Austrian population (Time Point 1, N = 281; Time Point 2, N = 277) completed a novel measure of belief in conspiracy theories concerning the abduction of Kampusch, as well as measures of general conspiracist ideation, self-esteem, paranormal and superstitious beliefs, cognitive ability, and media exposure to the Kampusch case. Results indicated that although belief in the Kampusch conspiracy theory declined between testing periods, the effect size of the difference was small. In addition, belief in the Kampusch conspiracy theory was significantly predicted by general conspiracist ideation at both time points. The need to conduct further longitudinal tests of conspiracist ideation is emphasized in conclusion. PMID:23745118
Cabrieto, Jedelyn; Tuerlinckx, Francis; Kuppens, Peter; Hunyadi, Borbála; Ceulemans, Eva
2018-01-15
Detecting abrupt correlation changes in multivariate time series is crucial in many application fields such as signal processing, functional neuroimaging, climate studies, and financial analysis. To detect such changes, several promising correlation change tests exist, but they may suffer from severe loss of power when there is actually more than one change point underlying the data. To deal with this drawback, we propose a permutation based significance test for Kernel Change Point (KCP) detection on the running correlations. Given a requested number of change points K, KCP divides the time series into K + 1 phases by minimizing the within-phase variance. The new permutation test looks at how the average within-phase variance decreases when K increases and compares this to the results for permuted data. The results of an extensive simulation study and applications to several real data sets show that, depending on the setting, the new test performs either at par or better than the state-of-the art significance tests for detecting the presence of correlation changes, implying that its use can be generally recommended.
Natoli, Lisa; Guy, Rebecca J.; Shephard, Mark; Causer, Louise; Badman, Steven G.; Hengel, Belinda; Tangey, Annie; Ward, James; Coburn, Tony; Anderson, David; Kaldor, John; Maher, Lisa
2015-01-01
Background Point-of-care tests for chlamydia (CT) and gonorrhoea (NG) could increase the uptake and timeliness of testing and treatment, contribute to improved disease control and reduce reproductive morbidity. The GeneXpert (Xpert CT/NG assay), suited to use at the point-of-care, is being used in the TTANGO randomised controlled trial (RCT) in 12 remote Australian health services with a high burden of sexually transmissible infections (STIs). This represents the first ever routine use of a molecular point-of-care diagnostic for STIs in primary care. The purpose of this study was to explore the acceptability of the GeneXpert to primary care staff in remote Australia. Methods In-depth qualitative interviews were conducted with 16 staff (registered or enrolled nurses and Aboriginal Health Workers/Practitioners) trained and experienced with GeneXpert testing. Interviews were digitally-recorded and transcribed verbatim prior to content analysis. Results Most participants displayed positive attitudes, indicating the test was both easy to use and useful in their clinical context. Participants indicated that point-of-care testing had improved management of STIs, resulting in more timely and targeted treatment, earlier commencement of partner notification, and reduced follow up efforts associated with client recall. Staff expressed confidence in point-of-care test results and treating patients on this basis, and reported greater job satisfaction. While point-of-care testing did not negatively impact on client flow, several found the manual documentation processes time consuming, suggesting that improved electronic connectivity and test result transfer between the GeneXpert and patient management systems could overcome this. Managing positive test results in a shorter time frame was challenging for some but most found it satisfying to complete episodes of care more quickly. Conclusions In the context of a RCT, health professionals working in remote primary care in Australia found the GeneXpert highly acceptable. These findings have implications for use in other primary care settings around the world. PMID:26713441
Portable Low-Volume Therapy for Severe Blood Loss
2013-06-01
with Tukey’s post hoc test were performed to find treatment differences within different time points for total hemoglobin (tHb), pH, pressure of...Tukey’s post hoc test were performed to find treatment differences within time points. No correlation was observed for any of the parameters at any...Department of the Army position, policy or decision unless so designated by other documentation. REPORT DOCUMENTATION PAGE Form Approved OMB
40 CFR 1054.145 - Are there interim provisions that apply only for a limited time?
Code of Federal Regulations, 2011 CFR
2011-07-01
... scheduled emission-related maintenance falls within 10 hours of a test point, delay the maintenance until the engine reaches the test point. Measure emissions before and after peforming the maintenance. Use... data under 40 CFR 1060.235(e) for your emission family. (j) Continued use of 40 CFR part 90 test...
40 CFR 1054.145 - Are there interim provisions that apply only for a limited time?
Code of Federal Regulations, 2012 CFR
2012-07-01
... scheduled emission-related maintenance falls within 10 hours of a test point, delay the maintenance until the engine reaches the test point. Measure emissions before and after peforming the maintenance. Use... data under 40 CFR 1060.235(e) for your emission family. (j) Continued use of 40 CFR part 90 test...
Power of tests for comparing trend curves with application to national immunization survey (NIS).
Zhao, Zhen
2011-02-28
To develop statistical tests for comparing trend curves of study outcomes between two socio-demographic strata across consecutive time points, and compare statistical power of the proposed tests under different trend curves data, three statistical tests were proposed. For large sample size with independent normal assumption among strata and across consecutive time points, the Z and Chi-square test statistics were developed, which are functions of outcome estimates and the standard errors at each of the study time points for the two strata. For small sample size with independent normal assumption, the F-test statistic was generated, which is a function of sample size of the two strata and estimated parameters across study period. If two trend curves are approximately parallel, the power of Z-test is consistently higher than that of both Chi-square and F-test. If two trend curves cross at low interaction, the power of Z-test is higher than or equal to the power of both Chi-square and F-test; however, at high interaction, the powers of Chi-square and F-test are higher than that of Z-test. The measurement of interaction of two trend curves was defined. These tests were applied to the comparison of trend curves of vaccination coverage estimates of standard vaccine series with National Immunization Survey (NIS) 2000-2007 data. Copyright © 2011 John Wiley & Sons, Ltd.
Makizako, Hyuma; Shimada, Hiroyuki; Doi, Takehiko; Tsutsumimoto, Kota; Nakakubo, Sho; Hotta, Ryo; Suzuki, Takao
2017-04-01
Lower extremity functioning is important for maintaining activity in elderly people. Optimal cutoff points for standard measurements of lower extremity functioning would help identify elderly people who are not disabled but have a high risk of developing disability. The purposes of this study were: (1) to determine the optimal cutoff points of the Five-Times Sit-to-Stand Test and the Timed "Up & Go" Test for predicting the development of disability and (2) to examine the impact of poor performance on both tests on the prediction of the risk of disability in elderly people dwelling in the community. This was a prospective cohort study. A population of 4,335 elderly people dwelling in the community (mean age = 71.7 years; 51.6% women) participated in baseline assessments. Participants were monitored for 2 years for the development of disability. During the 2-year follow-up period, 161 participants (3.7%) developed disability. The optimal cutoff points of the Five-Times Sit-to-Stand Test and the Timed "Up & Go" Test for predicting the development of disability were greater than or equal to 10 seconds and greater than or equal to 9 seconds, respectively. Participants with poor performance on the Five-Times Sit-to-Stand Test (hazard ratio = 1.88; 95% CI = 1.11-3.20), the Timed "Up & Go" Test (hazard ratio = 2.24; 95% CI = 1.42-3.53), or both tests (hazard ratio = 2.78; 95% CI = 1.78-4.33) at the baseline assessment had a significantly higher risk of developing disability than participants who had better lower extremity functioning. All participants had good initial functioning and participated in assessments on their own. Causes of disability were not assessed. Assessments of lower extremity functioning with the Five-Times Sit-to-Stand Test and the Timed "Up & Go" Test, especially poor performance on both tests, were good predictors of future disability in elderly people dwelling in the community. © 2017 American Physical Therapy Association
Time-varying Entry Heating Profile Replication with a Rotating Arc Jet Test Article
NASA Technical Reports Server (NTRS)
Grinstead, Jay Henderson; Venkatapathy, Ethiraj; Noyes, Eric A.; Mach, Jeffrey J.; Empey, Daniel M.; White, Todd R.
2014-01-01
A new approach for arc jet testing of thermal protection materials at conditions approximating the time-varying conditions of atmospheric entry was developed and demonstrated. The approach relies upon the spatial variation of heat flux and pressure over a cylindrical test model. By slowly rotating a cylindrical arc jet test model during exposure to an arc jet stream, each point on the test model will experience constantly changing applied heat flux. The predicted temporal profile of heat flux at a point on a vehicle can be replicated by rotating the cylinder at a prescribed speed and direction. An electromechanical test model mechanism was designed, built, and operated during an arc jet test to demonstrate the technique.
1992-10-01
MSFC Test Engineer performing a functional test on the TES. The TES can be operated as a refrigerator, with a minimum set point temperature of 4.0 degrees C, or as an incubator, with a maximum set point temperature 40.0 degrees C of the set point. The TES can be set to maintain a constant temperature or programmed to change temperature settings over time, internal temperature recorded by a date logger.
NASA Technical Reports Server (NTRS)
Levine, Jack; Rumsey, Charles B.
1958-01-01
The aerodynamic heat transfer to a hemispherical concave nose has been measured in free flight at Mach numbers from 3.5 to 6.6 with corresponding Reynolds numbers based on nose diameter from 7.4 x 10(exp 6) to 14 x 10(exp 6). Over the test Mach number range the heating on the cup nose, expressed as a ratio to the theoretical stagnation-point heating on a hemisphere nose of the same diameter, varied from 0.05 to 0.13 at the stagnation point of the cup, was approximately 0.1 at other locations within 40 deg of the stagnation point, and varied from 0.6 to 0.8 just inside the lip where the highest heating rates occurred. At a Mach number of 5 the total heat input integrated over the surface of the cup nose including the lip was 0.55 times the theoretical value for a hemisphere nose with laminar boundary layer and 0.76 times that for a flat face. The heating at the stagnation point was approximately 1/5 as great as steady-flow tunnel results. Extremely high heating rates at the stagnation point (on the order of 30 times the stagnation-point values of the present test), which have occurred in conjunction with unsteady oscillatory flow around cup noses in wind-tunnel tests at Mach and Reynolds numbers within the present test range, were not observed.
NASA Astrophysics Data System (ADS)
Vu, Tinh Thi; Kiesel, Jens; Guse, Bjoern; Fohrer, Nicola
2017-04-01
The damming of rivers causes one of the most considerable impacts of our society on the riverine environment. More than 50% of the world's streams and rivers are currently impounded by dams before reaching the oceans. The construction of dams is of high importance in developing and emerging countries, i.e. for power generation and water storage. In the Vietnamese Vu Gia - Thu Bon Catchment (10,350 km2), about 23 dams were built during the last decades and store approximately 2,156 billion m3 of water. The water impoundment in 10 dams in upstream regions amounts to 17 % of the annual discharge volume. It is expected that impacts from these dams have altered the natural flow regime. However, up to now it is unclear how the flow regime was altered. For this, it needs to be investigated at what point in time these changes became significant and detectable. Many approaches exist to detect changes in stationary or consistency of hydrological records using statistical analysis of time series for the pre- and post-dam period. The objective of this study is to reliably detect and assess hydrologic shifts occurring in the discharge regime of an anthropogenically influenced river basin, mainly affected by the construction of dams. To achieve this, we applied nine available change-point tests to detect change in mean, variance and median on the daily and annual discharge records at two main gauges of the basin. The tests yield conflicting results: The majority of tests found abrupt changes that coincide with the damming-period, while others did not. To interpret how significant the changes in discharge regime are, and to which different properties of the time series each test responded, we calculated Indicators of Hydrologic Alteration (IHAs) for the time period before and after the detected change points. From the results, we can deduce, that the change point tests are influenced in different levels by different indicator groups (magnitude, duration, frequency, etc) and that within the indicator groups, some indicators are more sensitive than others. For instance, extreme low-flow, especially 7- and, 30-day minima and mean minimum low flow, as well as the variability of monthly flow are highly-sensitive to most detected change points. Our study clearly shows that, the detected change points depend on which test is chosen. For an objective assessment of change points, it is therefore necessary to explain the change points by calculating differences in IHAs. This analysis can be used to assess which change point method reacts to which type of hydrological change and, more importantly, it can be used to rank the change points according to their overall impact on the discharge regime. This leads to an improved evaluation of hydrologic change-points caused by anthropogenic impacts. Our study clearly shows that, the detected change points depend on which test is chosen. For an objective assessment of change points, it is therefore necessary to explain the change points by calculating differences in IHAs. This analysis can be used to assess which change point method reacts to which type of hydrological change and, more importantly, it can be used to rank the change points according to their overall impact on the discharge regime. This leads to an improved evaluation of hydrologic change-points caused by anthropogenic impacts.
Experimental results for the rapid determination of the freezing point of fuels
NASA Technical Reports Server (NTRS)
Mathiprakasam, B.
1984-01-01
Two methods for the rapid determination of the freezing point of fuels were investigated: an optical method, which detected the change in light transmission from the disappearance of solid particles in the melted fuel; and a differential thermal analysis (DTA) method, which sensed the latent heat of fusion. A laboratory apparatus was fabricated to test the two methods. Cooling was done by thermoelectric modules using an ice-water bath as a heat sink. The DTA method was later modified to eliminate the reference fuel. The data from the sample were digitized and a point of inflection, which corresponds to the ASTM D-2386 freezing point (final melting point), was identified from the derivative. The apparatus was modifified to cool the fuel to -60 C and controls were added for maintaining constant cooling rate, rewarming rate, and hold time at minimum temperature. A parametric series of tests were run for twelve fuels with freezing points from -10 C to -50 C, varying cooling rate, rewarming rate, and hold time. Based on the results, an optimum test procedure was established. The results showed good agreement with ASTM D-2386 freezing point and differential scanning calorimetry results.
Point-of-care testing system enabling 30 min detection of influenza genes.
Abe, Tomoteru; Segawa, Yuji; Watanabe, Hidetoshi; Yotoriyama, Tasuku; Kai, Shinichi; Yasuda, Akio; Shimizu, Norio; Tojo, Naoko
2011-03-21
We developed a portable and easy-to-use nucleic acid amplification test (NAT) system for use in point-of-care testing (POCT). The system shows sensitivity that is sufficiently higher than that of the currently available rapid diagnostic kit and is comparable to that of real-time reverse transcription polymerase chain reaction (RT-PCR) for influenza testing. This journal is © The Royal Society of Chemistry 2011
A point-of-care chemistry test for reduction of turnaround and clinical decision time.
Lee, Eui Jung; Shin, Sang Do; Song, Kyoung Jun; Kim, Seong Chun; Cho, Jin Seong; Lee, Seung Chul; Park, Ju Ok; Cha, Won Chul
2011-06-01
Our study compared clinical decision time between patients managed with a point-of-care chemistry test (POCT) and patients managed with the traditional central laboratory test (CLT). This was a randomized controlled multicenter trial in the emergency departments (EDs) of 5 academic teaching hospitals. We randomly assigned patients to POCT or CLT stratified by the Emergency Severity Index. A POCT chemistry analyzer (Piccolo; Abaxis, Inc, Union City, Calif), which is able to test liver panel, renal panel, pancreas enzymes, lipid panel, electrolytes, and blood gases, was set up in each ED. Primary and secondary end point was turnaround time and door-to-clinical-decision time. The total 2323 patients were randomly assigned to the POCT group (n = 1167) or to the CLT group (n = 1156). All of the basic characteristics were similar in the 2 groups. The turnaround time (median, interquartile range [IQR]) of the POCT group was shorter than that of the CLT group (14, 12-19 versus 55, 45-69 minutes; P < .0001). The median (IQR) door-to-clinical-decision time was also shorter in the POCT compared with the CLT group (46, 33-61 versus 86, 68-107 minutes; P < .0001). The proportion of patients who had new decisions within 60 minutes was 72.8% for the POCT group and 12.5% for the CLT group (P < .0001). A POCT chemistry analyzer in the ED shortens the test turnaround and ED clinical decision times compared with CLT. Copyright © 2011 Elsevier Inc. All rights reserved.
Rego, Karen; Pereira, Kristen; MacDougall, James; Cruikshank, William
2018-01-01
Accurate identification of individuals with TB infection, is required to achieve the WHO's End TB Strategy goals. While there is general acceptance that the T-SPOT.TB test borderline category provides an opportunity to increase test resolution of results around the test cut-off point, this has not been investigated. 645,947 tests were analyzed to determine frequency of borderline results, effect of age and time between tests and associations between subjects' clinical risk factors and retest results. 645,947 tests produced 93.5% negatives, 4% positives, 0.6% invalids, and 1.8% borderlines. Within the borderline results, 5044 were repeated, with 59.2%, 20.0% and 20.2% resolving to negative, positive and borderline, respectively. Age of subject did not affect retest results; however, time between tests indicated that retest resolution occurred with greatest frequency after 90 days. TB risk factors were provided for 2640 subjects and 17% of low risk subjects with a high initial borderline resolved to negative while 27.6% of subjects with high risk and an initial low borderline resolved to positive, suggesting that these subjects could have been inappropriately classified if using a single cut-off point test with no borderline category. This study demonstrates the utility of the T-SPOT.TB test's borderline category to increase test resolution around the test cut-off point. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Polat, Metin; Korkmaz Eryılmaz, Selcen; Aydoğan, Sami
2018-01-01
In order to ensure that athletes achieve their highest performance levels during competitive seasons, monitoring their long-term performance data is crucial for understanding the impact of ongoing training programs and evaluating training strategies. The present study was thus designed to investigate the variations in body composition, maximal oxygen uptake (VO 2max ), and gas exchange threshold values of cross-country skiers across training phases throughout a season. In total, 15 athletes who participate in international cross-country ski competitions voluntarily took part in this study. The athletes underwent incremental treadmill running tests at 3 different time points over a period of 1 year. The first measurements were obtained in July, during the first preparation period; the second measurements were obtained in October, during the second preparation period; and the third measurements were obtained in February, during the competition period. Body weight, body mass index (BMI), body fat (%), as well as VO 2max values and gas exchange threshold, measured using V-slope method during the incremental running tests, were assessed at all 3 time points. The collected data were analyzed using SPSS 20 package software. Significant differences between the measurements were assessed using Friedman's twoway variance analysis with a post hoc option. The athletes' body weights and BMI measurements at the third point were significantly lower compared with the results of the second measurement ( p <0.001). Moreover, the incremental running test time was significantly higher at the third measurement, compared with both the first ( p <0.05) and the second ( p <0.01) measurements. Similarly, the running speed during the test was significantly higher at the third measurement time point compared with the first measurement time point ( p <0.05). Body fat (%), time to reach the gas exchange threshold, running speed at the gas exchange threshold, VO 2max , amount of oxygen consumed at gas exchange threshold level (VO 2GET ), maximal heart rate (HR max ), and heart rate at gas exchange threshold level (HR GET ) values did not significantly differ between the measurement time points ( p >0.05). VO 2max and gas exchange threshold values recorded during the third measurements, the timing of which coincided with the competitive season of the cross-country skiers, did not significantly change, but their incremental running test time and running speed significantly increased while their body weight and BMI significantly decreased. These results indicate that the cross-country skiers developed a tolerance for high-intensity exercise and reached their highest level of athletic performance during the competitive season.
40 CFR 797.1300 - Daphnid acute toxicity test.
Code of Federal Regulations, 2010 CFR
2010-07-01
... continuous exposure over a specified period of time. In this guideline, the effect measured is immobilization... at a point in time, or passing through the test chamber during a specific interval. (7) Static system..., daphnids which have been cultured and acclimated in accordance with the test design are randomly placed...
40 CFR 797.1300 - Daphnid acute toxicity test.
Code of Federal Regulations, 2014 CFR
2014-07-01
... continuous exposure over a specified period of time. In this guideline, the effect measured is immobilization... at a point in time, or passing through the test chamber during a specific interval. (7) Static system..., daphnids which have been cultured and acclimated in accordance with the test design are randomly placed...
40 CFR 797.1300 - Daphnid acute toxicity test.
Code of Federal Regulations, 2013 CFR
2013-07-01
... continuous exposure over a specified period of time. In this guideline, the effect measured is immobilization... at a point in time, or passing through the test chamber during a specific interval. (7) Static system..., daphnids which have been cultured and acclimated in accordance with the test design are randomly placed...
40 CFR 797.1300 - Daphnid acute toxicity test.
Code of Federal Regulations, 2012 CFR
2012-07-01
... continuous exposure over a specified period of time. In this guideline, the effect measured is immobilization... at a point in time, or passing through the test chamber during a specific interval. (7) Static system..., daphnids which have been cultured and acclimated in accordance with the test design are randomly placed...
40 CFR 797.1300 - Daphnid acute toxicity test.
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous exposure over a specified period of time. In this guideline, the effect measured is immobilization... at a point in time, or passing through the test chamber during a specific interval. (7) Static system..., daphnids which have been cultured and acclimated in accordance with the test design are randomly placed...
Effect of home testing of international normalized ratio on clinical events.
Matchar, David B; Jacobson, Alan; Dolor, Rowena; Edson, Robert; Uyeda, Lauren; Phibbs, Ciaran S; Vertrees, Julia E; Shih, Mei-Chiung; Holodniy, Mark; Lavori, Philip
2010-10-21
Warfarin anticoagulation reduces thromboembolic complications in patients with atrial fibrillation or mechanical heart valves, but effective management is complex, and the international normalized ratio (INR) is often outside the target range. As compared with venous plasma testing, point-of-care INR measuring devices allow greater testing frequency and patient involvement and may improve clinical outcomes. We randomly assigned 2922 patients who were taking warfarin because of mechanical heart valves or atrial fibrillation and who were competent in the use of point-of-care INR devices to either weekly self-testing at home or monthly high-quality testing in a clinic. The primary end point was the time to a first major event (stroke, major bleeding episode, or death). The patients were followed for 2.0 to 4.75 years, for a total of 8730 patient-years of follow-up. The time to the first primary event was not significantly longer in the self-testing group than in the clinic-testing group (hazard ratio, 0.88; 95% confidence interval, 0.75 to 1.04; P=0.14). The two groups had similar rates of clinical outcomes except that the self-testing group reported more minor bleeding episodes. Over the entire follow-up period, the self-testing group had a small but significant improvement in the percentage of time during which the INR was within the target range (absolute difference between groups, 3.8 percentage points; P<0.001). At 2 years of follow-up, the self-testing group also had a small but significant improvement in patient satisfaction with anticoagulation therapy (P=0.002) and quality of life (P<0.001). As compared with monthly high-quality clinic testing, weekly self-testing did not delay the time to a first stroke, major bleeding episode, or death to the extent suggested by prior studies. These results do not support the superiority of self-testing over clinic testing in reducing the risk of stroke, major bleeding episode, and death among patients taking warfarin therapy. (Funded by the Department of Veterans Affairs Cooperative Studies Program; ClinicalTrials.gov number, NCT00032591.).
NASA Technical Reports Server (NTRS)
Sahai, Ranjana; Pierce, Larry; Cicolani, Luigi; Tischler, Mark
1998-01-01
Helicopter slung load operations are common in both military and civil contexts. The slung load adds load rigid body modes, sling stretching, and load aerodynamics to the system dynamics, which can degrade system stability and handling qualities, and reduce the operating envelope of the combined system below that of the helicopter alone. Further, the effects of the load on system dynamics vary significantly among the large range of loads, slings, and flight conditions that a utility helicopter will encounter in its operating life. In this context, military helicopters and loads are often qualified for slung load operations via flight tests which can be time consuming and expensive. One way to reduce the cost and time required to carry out these tests and generate quantitative data more readily is to provide an efficient method for analysis during the flight, so that numerous test points can be evaluated in a single flight test, with evaluations performed in near real time following each test point and prior to clearing the aircraft to the next point. Methodology for this was implemented at Ames and demonstrated in slung load flight tests in 1997 and was improved for additional flight tests in 1999. The parameters of interest for the slung load tests are aircraft handling qualities parameters (bandwidth and phase delay), stability margins (gain and phase margin), and load pendulum roots (damping and natural frequency). A procedure for the identification of these parameters from frequency sweep data was defined using the CIFER software package. CIFER is a comprehensive interactive package of utilities for frequency domain analysis previously developed at Ames for aeronautical flight test applications. It has been widely used in the US on a variety of aircraft, including some primitive flight time analysis applications.
40 CFR 1054.145 - Are there interim provisions that apply only for a limited time?
Code of Federal Regulations, 2010 CFR
2010-07-01
... scheduled emission-related maintenance falls within 10 hours of a test point, delay the maintenance until the engine reaches the test point. Measure emissions before and after peforming the maintenance. Use... example, for the fuel line permeation standards starting in 2012, equipment manufacturers may order a...
Stein, Marjorie W; Frank, Susan J; Roberts, Jeffrey H; Finkelstein, Malka; Heo, Moonseong
2016-05-01
The aim of this study was to determine whether group-based or didactic teaching is more effective to teach ACR Appropriateness Criteria to medical students. An identical pretest, posttest, and delayed multiple-choice test was used to evaluate the efficacy of the two teaching methods. Descriptive statistics comparing test scores were obtained. On the posttest, the didactic group gained 12.5 points (P < .0001), and the group-based learning students gained 16.3 points (P < .0001). On the delayed test, the didactic group gained 14.4 points (P < .0001), and the group-based learning students gained 11.8 points (P < .001). The gains in scores on both tests were statistically significant for both groups. However, the differences in scores were not statistically significant comparing the two educational methods. Compared with didactic lectures, group-based learning is more enjoyable, time efficient, and equally efficacious. The choice of educational method can be individualized for each institution on the basis of group size, time constraints, and faculty availability. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Moving Force Identification: a Time Domain Method
NASA Astrophysics Data System (ADS)
Law, S. S.; Chan, T. H. T.; Zeng, Q. H.
1997-03-01
The solution for the vertical dynamic interaction forces between a moving vehicle and the bridge deck is analytically derived and experimentally verified. The deck is modelled as a simply supported beam with viscous damping, and the vehicle/bridge interaction force is modelled as one-point or two-point loads with fixed axle spacing, moving at constant speed. The method is based on modal superposition and is developed to identify the forces in the time domain. Both cases of one-point and two-point forces moving on a simply supported beam are simulated. Results of laboratory tests on the identification of the vehicle/bridge interaction forces are presented. Computation simulations and laboratory tests show that the method is effective, and acceptable results can be obtained by combining the use of bending moment and acceleration measurements.
Gupta, Ekta; Agarwala, Pragya; Kumar, Guresh; Maiwall, Rakhi; Sarin, Shiv Kumar
2017-03-01
Molecular testing at the point-of-care may turn out to be game changer for HCV diagnosis and treatment monitoring, through increased sensitivity, reduced turnaround time, and ease of performance. One such assay GeneXpert ® has recently been released. Comparative analysis between performances of GeneXpert ® and Abbott HCV-RNA was done. 174 HCV infected patients were recruited and, one time plasma samples from 154 patients and repeated samples from 20 patients, obtained at specific treatment time-points (0, 4, 12 and 24) weeks were serially re-tested on Xpert ® . Genotype 3 was the commonest, seen in 80 (66%) of the cases, genotype 1 in 34 (28.3%), genotype 4 in 4 (3.3%) and genotypes 2 and 5 in 1 (0.8%) each. Median HCV RNA load was 4.69 log 10 (range: 0-6.98log 10 ) IU/ml. Overall a very good correlation was seen between the two assays (R 2 =0.985), concordance of the results between the assays was seen in 138 samples (89.6%). High and low positive standards were tested ten times on Xpert ® to evaluate the precision and the coefficient of variation was 0.01 for HPC and 0.07 for the LPC. Monitoring of patients on two different regimes of treatment, pegylated interferon plus ribavirin and sofosbuvir plus ribavirin was done by both the systems at baseline, 4, 12 and 24 weeks. Perfect correlation between the assays in the course of therapy at different treatment time- point in genotypes 3 and 1 was seen. The study demonstrates excellent performance of the Xpert ® HCV assay in viral load assessment and in treatment course monitoring consistency. Copyright © 2017 Elsevier B.V. All rights reserved.
Computer-assisted recording of tensile tests for the evaluation of serrated flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weinhandl, H.; Mitter, F.; Bernt, W.
1994-12-01
In a previous paper the authors pointed out the difficulties which arise in the evaluation of serrated flow curves when the applied tensile strain rates are just above normal''. The recording system of tensile testing machines which were built, say, twenty years ago, are not capable of recording the full size of the load drops due to the inertia of the recording pen. This handicap was then overcome by establishing correction factors which were determined from recording a small number of load drops with an oscilloscope. Modern testing machines are equipped with digital recording. The disadvantage of the common systemmore » is, however, their limited capacity, so that not enough space for data points is available. Consequently, the time intervals between data points are of the order of tenths of seconds. It will become obvious from the present results that such a time interval is too large for recording a correct serration size. This report is concerned with the recording of complete load-extension relations during tensile tests using a computer which is capable of storing the data at sufficiently small time intervals.« less
A Few Observations and Remarks on Time Effectiveness of Interactive Electronic Testing
ERIC Educational Resources Information Center
Magdin, Martin; Turcáni, Milan
2015-01-01
In the paper, we point out several observations and remarks on time effectiveness of electronic testing, in particular of its new form (interactive tests). A test is often used as an effective didactic tool for evaluating the extent of gained cognitive capabilities. According to authors Rudman (1989) and Wang (2003) it is provable that the…
Shi, Xiaoping; Wu, Yuehua; Rao, Calyampudi Radhakrishna
2018-06-05
The change-point detection has been carried out in terms of the Euclidean minimum spanning tree (MST) and shortest Hamiltonian path (SHP), with successful applications in the determination of authorship of a classic novel, the detection of change in a network over time, the detection of cell divisions, etc. However, these Euclidean graph-based tests may fail if a dataset contains random interferences. To solve this problem, we present a powerful non-Euclidean SHP-based test, which is consistent and distribution-free. The simulation shows that the test is more powerful than both Euclidean MST- and SHP-based tests and the non-Euclidean MST-based test. Its applicability in detecting both landing and departure times in video data of bees' flower visits is illustrated.
Tcl as a Software Environment for a TCS
NASA Astrophysics Data System (ADS)
Terrett, David L.
2002-12-01
This paper describes how the Tcl scripting language and C API has been used as the software environment for a telescope pointing kernel so that new pointing algorithms and software architectures can be developed and tested without needing a real-time operating system or real-time software environment. It has enabled development to continue outside the framework of a specific telescope project while continuing to build a system that is sufficiently complete to be capable of controlling real hardware but expending minimum effort on replacing the services that would normally by provided by a real-time software environment. Tcl is used as a scripting language for configuring the system at startup and then as the command interface for controlling the running system; the Tcl C language API is used to provided a system independent interface to file and socket I/O and other operating system services. The pointing algorithms themselves are implemented as a set of C++ objects calling C library functions that implement the algorithms described in [2]. Although originally designed as a test and development environment, the system, running as a soft real-time process on Linux, has been used to test the SOAR mount control system and will be used as the pointing kernel of the SOAR telescope control system
Impact of Hypnosis Intervention in Alleviating Psychological and Physical Symptoms During Pregnancy.
Beevi, Zuhrah; Low, Wah Yun; Hassan, Jamiyah
2016-04-01
Physical symptoms (e.g., vomiting) and psychological symptoms (stress, anxiety, and depression) during pregnancy are common. Various strategies such as hypnosis are available to reduce these symptoms. The objective of the authors in this study is to investigate the impact of a hypnosis intervention in reducing physical and psychological symptoms during pregnancy. A pre-test/post-test quasi-experimental design was employed in this study. The hypnosis intervention was given to the experimental group participants at weeks 16 (baseline), 20 (time point 1), 28 (time point 2), and 36 (time point 3) of their pregnancy. Participants in the control group received only the traditional antenatal care. Participants from both groups completed the Depression Anxiety Stress Scale-21 (DASS-21) and a Pregnancy Symptoms Checklist at weeks 16, 20, 28 and 36 of pregnancy. Results indicated that stress and anxiety symptoms were significantly reduced for the experimental group, but not for the control group. Although mean differences for the depressive symptoms were not significant, the experimental group had lower symptoms at time point 3. The physical symptoms' results showed significant group differences at time point 3, indicating a reduction in the experience of physical symptoms for the experimental group participants. Our study showed that hypnosis intervention during pregnancy aided in reducing physical and psychological symptoms during pregnancy.
Canali, Inesângela; Petersen Schmidt Rosito, Letícia; Siliprandi, Bruno; Giugno, Cláudia; Selaimen da Costa, Sady
The diagnosis of Eustachian tube dysfunctions is essential for better understanding of the pathogenesis of chronic otitis media. A series of tests to assess tube function are described in the literature; however, they are methodologically heterogeneous, with differences ranging from application protocols to standardization of tests and their results. To evaluate the variation in middle ear pressure in patients with tympanic membrane retraction and in normal patients during tube function tests, as well as to evaluate intra-individual variation between these tests. An observational, contemporary, cross-sectional study was conducted, in which the factor under study was the variation in middle ear pressure during tube function tests (Valsalva maneuver, sniff test, Toynbee maneuver) in healthy patients and in patients with mild and moderate/severe tympanic retraction. A total of 38 patients (76 ears) were included in the study. Patients underwent tube function tests at two different time points to determine pressure measurements after each maneuver. Statistical analysis was performed using SPSS software, version 18.0, considering p-values <0.05 as statistically significant. Mean (standard deviation) age was 11 (2.72) years; 55.3% of patients were male and 44.7% female. The prevalence of type A tympanogram was higher among participants with healthy ears and those with mild retraction, whereas type C tympanograms were more frequent in the moderate/severe retraction group. An increase in middle ear pressure was observed during the Valsalva maneuver at the first time point evaluated in all three groups of ears (p=0.012). The variation in pressure was not significant either for the sniff test or for the Toynbee maneuver at the two time points evaluated (p≥0.05). Agreement between measurements obtained at the two different time points was weak to moderate for all tests in all three groups of ears, and the variations in discrepancy between measurements were higher in ears with moderate/severe tympanic retraction. In this study population, the mean pressure in the middle ear showed significant variation only during the Valsalva maneuver at the first time point evaluated in the three groups of ears. Normal ears and those with mild retraction behaved similarly in all tests. The tested maneuvers exhibited weak to moderate intra-individual variation, with the greatest variation occurring in ears with moderate/severe retraction. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
De Schacht, Caroline; Lucas, Carlota; Sitoe, Nádia; Machekano, Rhoderick; Chongo, Patrina; Temmerman, Marleen; Tobaiwa, Ocean; Guay, Laura; Kassaye, Seble; Jani, Ilesh V
2015-01-01
Anemia, syphilis and HIV are high burden diseases among pregnant women in sub-Saharan Africa. A quasi-experimental study was conducted in four health facilities in Southern Mozambique to evaluate the effect of point-of-care technologies for hemoglobin quantification, syphilis testing and CD4+ T-cell enumeration performed within maternal and child health services on testing and treatment coverage, and assessing acceptability by health workers. Demographic and testing data on women attending first antenatal care services were extracted from existing records, before (2011; n = 865) and after (2012; n = 808) introduction of point-of-care testing. Study outcomes per health facility were compared using z-tests (categorical variables) and Wilcoxon rank-sum test (continuous variables), while inverse variance weights were used to adjust for possible cluster effects in the pooled analysis. A structured acceptability-assessment interview was conducted with health workers before (n = 22) and after (n = 19). After implementation of point-of-care testing, there was no significant change in uptake of overall hemoglobin screening (67.9% to 83.0%; p = 0.229), syphilis screening (80.8% to 87.0%; p = 0.282) and CD4+ T-cell testing (84.9% to 83.5%; p = 0.930). Initiation of antiretroviral therapy for treatment eligible women was similar in the weighted analysis before and after, with variability among the sites. Time from HIV diagnosis to treatment initiation decreased (median of 44 days to 17 days; p<0.0001). A generally good acceptability for point-of-care testing was seen among health workers. Point-of-care CD4+ T-cell enumeration resulted in a decreased time to initiation of antiretroviral therapy among treatment eligible women, without significant increase in testing coverage. Overall hemoglobin and syphilis screening increased. Despite the perception that point-of-care technologies increase access to health services, the variability in results indicate the potential for detrimental effects in some settings. Local context needs to be considered and services restructured to accommodate innovative technologies in order to improve service delivery to expectant mothers.
Freitag, Sonja
2014-01-01
Objectives: To examine the influence of the two following factors on the proportion of time that nurses spend in a forward-bending trunk posture: (i) the bed height during basic care activities at the bedside and (ii) the work method during basic care activities in the bathroom. A further aim was to examine the connection between the proportion of time spent in a forward-bending posture and the perceived exertion. Methods: Twelve nurses in a geriatric nursing home each performed a standardized care routine at the bedside and in the bathroom. The CUELA (German abbreviation for ‘computer-assisted recording and long-term analysis of musculoskeletal loads’) measuring system was used to record all trunk inclinations. Each participant conducted three tests with the bed at different heights (knee height, thigh height, and hip height) and in the bathroom, three tests were performed with different work methods (standing, kneeling, and sitting). After each test, participants rated their perceived exertion on the 15-point Borg scale (6 = no exertion at all and 20 = exhaustion). Results: If the bed was raised from knee to thigh level, the proportion of time spent in an upright position increased by 8.2% points. However, the effect was not significant (P = 0.193). Only when the bed was raised to hip height, there was a significant increase of 19.8% points (reference: thigh level; P = 0.003) and 28.0% points (reference: knee height; P < 0.001). Bathroom tests: compared with the standing work method, the kneeling and sitting work methods led to a significant increase in the proportion of time spent in an upright posture, by 19.4% points (P = 0.003) and 25.7% points (P < 0.001), respectively. The greater the proportion of time spent in an upright position, the lower the Borg rating (P < 0.001) awarded. Conclusions: The higher the proportion of time that nursing personnel work in an upright position, the less strenuous they perceive the work to be. Raising the bed to hip height and using a stool in the bathroom significantly increase the proportion of time that nursing personnel work in an upright position. Nursing staff can spend a considerably greater proportion of their time in an ergonomic posture if stools and height-adjustable beds are provided in healthcare institutions. PMID:24371043
Freitag, Sonja; Seddouki, Rachida; Dulon, Madeleine; Kersten, Jan Felix; Larsson, Tore J; Nienhaus, Albert
2014-04-01
To examine the influence of the two following factors on the proportion of time that nurses spend in a forward-bending trunk posture: (i) the bed height during basic care activities at the bedside and (ii) the work method during basic care activities in the bathroom. A further aim was to examine the connection between the proportion of time spent in a forward-bending posture and the perceived exertion. Twelve nurses in a geriatric nursing home each performed a standardized care routine at the bedside and in the bathroom. The CUELA (German abbreviation for 'computer-assisted recording and long-term analysis of musculoskeletal loads') measuring system was used to record all trunk inclinations. Each participant conducted three tests with the bed at different heights (knee height, thigh height, and hip height) and in the bathroom, three tests were performed with different work methods (standing, kneeling, and sitting). After each test, participants rated their perceived exertion on the 15-point Borg scale (6 = no exertion at all and 20 = exhaustion). If the bed was raised from knee to thigh level, the proportion of time spent in an upright position increased by 8.2% points. However, the effect was not significant (P = 0.193). Only when the bed was raised to hip height, there was a significant increase of 19.8% points (reference: thigh level; P = 0.003) and 28.0% points (reference: knee height; P < 0.001). Bathroom tests: compared with the standing work method, the kneeling and sitting work methods led to a significant increase in the proportion of time spent in an upright posture, by 19.4% points (P = 0.003) and 25.7% points (P < 0.001), respectively. The greater the proportion of time spent in an upright position, the lower the Borg rating (P < 0.001) awarded. The higher the proportion of time that nursing personnel work in an upright position, the less strenuous they perceive the work to be. Raising the bed to hip height and using a stool in the bathroom significantly increase the proportion of time that nursing personnel work in an upright position. Nursing staff can spend a considerably greater proportion of their time in an ergonomic posture if stools and height-adjustable beds are provided in healthcare institutions.
NASA Astrophysics Data System (ADS)
Lokoshchenko, A.; Teraud, W.
2018-04-01
The work describes an experimental research of creep of cylindrical tensile test specimens made of aluminum alloy D16T at a constant temperature of 400°C. The issue to be examined was the necking at different values of initial tensile stresses. The use of a developed noncontacting measuring system allowed us to see variations in the specimen shape and to estimate the true stress in various times. Based on the obtained experimental data, several criteria were proposed for describing the point of time at which the necking occurs (necking point). Calculations were carried out at various values of the parameters in these criteria. The relative interval of deformation time in which the test specimen is uniformly stretched was also determined.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... You may extend the sampling time to improve measurement accuracy of PM emissions, using good..., you may omit speed, torque, and power points from the duty-cycle regression statistics if the... mapped. (2) For variable-speed engines without low-speed governors, you may omit torque and power points...
Code of Federal Regulations, 2012 CFR
2012-07-01
.... You may extend the sampling time to improve measurement accuracy of PM emissions, using good..., you may omit speed, torque, and power points from the duty-cycle regression statistics if the... mapped. (2) For variable-speed engines without low-speed governors, you may omit torque and power points...
A test of alternative estimators for volume at time 1 from remeasured point samples
Francis A. Roesch; Edwin J. Green; Charles T. Scott
1993-01-01
Two estimators for volume at time 1 for use with permanent horizontal point samples are evaluated. One estimator, used traditionally, uses only the trees sampled at time 1, while the second estimator, originally presented by Roesch and coauthors (F.A. Roesch, Jr., E.J. Green, and C.T. Scott. 1989. For. Sci. 35(2):281-293). takes advantage of additional sample...
Analyzing survival curves at a fixed point in time for paired and clustered right-censored data
Su, Pei-Fang; Chi, Yunchan; Lee, Chun-Yi; Shyr, Yu; Liao, Yi-De
2018-01-01
In clinical trials, information about certain time points may be of interest in making decisions about treatment effectiveness. Rather than comparing entire survival curves, researchers can focus on the comparison at fixed time points that may have a clinical utility for patients. For two independent samples of right-censored data, Klein et al. (2007) compared survival probabilities at a fixed time point by studying a number of tests based on some transformations of the Kaplan-Meier estimators of the survival function. However, to compare the survival probabilities at a fixed time point for paired right-censored data or clustered right-censored data, their approach would need to be modified. In this paper, we extend the statistics to accommodate the possible within-paired correlation and within-clustered correlation, respectively. We use simulation studies to present comparative results. Finally, we illustrate the implementation of these methods using two real data sets. PMID:29456280
Optimization models for flight test scheduling
NASA Astrophysics Data System (ADS)
Holian, Derreck
As threats around the world increase with nations developing new generations of warfare technology, the Unites States is keen on maintaining its position on top of the defense technology curve. This in return indicates that the U.S. military/government must research, develop, procure, and sustain new systems in the defense sector to safeguard this position. Currently, the Lockheed Martin F-35 Joint Strike Fighter (JSF) Lightning II is being developed, tested, and deployed to the U.S. military at Low Rate Initial Production (LRIP). The simultaneous act of testing and deployment is due to the contracted procurement process intended to provide a rapid Initial Operating Capability (IOC) release of the 5th Generation fighter. For this reason, many factors go into the determination of what is to be tested, in what order, and at which time due to the military requirements. A certain system or envelope of the aircraft must be assessed prior to releasing that capability into service. The objective of this praxis is to aide in the determination of what testing can be achieved on an aircraft at a point in time. Furthermore, it will define the optimum allocation of test points to aircraft and determine a prioritization of restrictions to be mitigated so that the test program can be best supported. The system described in this praxis has been deployed across the F-35 test program and testing sites. It has discovered hundreds of available test points for an aircraft to fly when it was thought none existed thus preventing an aircraft from being grounded. Additionally, it has saved hundreds of labor hours and greatly reduced the occurrence of test point reflight. Due to the proprietary nature of the JSF program, details regarding the actual test points, test plans, and all other program specific information have not been presented. Generic, representative data is used for example and proof-of-concept purposes. Apart from the data correlation algorithms, the optimization associated with restriction removal is based on heuristic approaches to support the reality of flight test in both solution space and computational time. Exact methods for yielding an optimized solution will be discussed however they are not directly applicable to the flight test problem and therefore have not been included in the system.
NASA Astrophysics Data System (ADS)
Machiwal, Deepesh; Gupta, Ankit; Jha, Madan Kumar; Kamble, Trupti
2018-04-01
This study investigated trends in 35 years (1979-2013) temperature (maximum, Tmax and minimum, Tmin) and rainfall at annual and seasonal (pre-monsoon, monsoon, post-monsoon, and winter) scales for 31 grid points in a coastal arid region of India. Box-whisker plots of annual temperature and rainfall time series depict systematic spatial gradients. Trends were examined by applying eight tests, such as Kendall rank correlation (KRC), Spearman rank order correlation (SROC), Mann-Kendall (MK), four modified MK tests, and innovative trend analysis (ITA). Trend magnitudes were quantified by Sen's slope estimator, and a new method was adopted to assess the significance of linear trends in MK-test statistics. It was found that the significant serial correlation is prominent in the annual and post-monsoon Tmax and Tmin, and pre-monsoon Tmin. The KRC and MK tests yielded similar results in close resemblance with the SROC test. The performance of two modified MK tests considering variance-correction approaches was found superior to the KRC, MK, modified MK with pre-whitening, and ITA tests. The performance of original MK test is poor due to the presence of serial correlation, whereas the ITA method is over-sensitive in identifying trends. Significantly increasing trends are more prominent in Tmin than Tmax. Further, both the annual and monsoon rainfall time series have a significantly increasing trend of 9 mm year-1. The sequential significance of linear trend in MK test-statistics is very strong (R 2 ≥ 0.90) in the annual and pre-monsoon Tmin (90% grid points), and strong (R 2 ≥ 0.75) in monsoon Tmax (68% grid points), monsoon, post-monsoon, and winter Tmin (respectively 65, 55, and 48% grid points), as well as in the annual and monsoon rainfalls (respectively 68 and 61% grid points). Finally, this study recommends use of variance-corrected MK test for the precise identification of trends. It is emphasized that the rising Tmax may hamper crop growth due to enhanced metabolic-activities and shortened crop-duration. Likewise, increased Tmin may result in lesser crop and biomass yields owing to the increased respiration.
Optimizing point-of-care testing in clinical systems management.
Kost, G J
1998-01-01
The goal of improving medical and economic outcomes calls for leadership based on fundamental principles. The manager of clinical systems works collaboratively within the acute care center to optimize point-of-care testing through systematic approaches such as integrative strategies, algorithms, and performance maps. These approaches are effective and efficacious for critically ill patients. Optimizing point-of-care testing throughout the entire health-care system is inherently more difficult. There is potential to achieve high-quality testing, integrated disease management, and equitable health-care delivery. Despite rapid change and economic uncertainty, a macro-strategic, information-integrated, feedback-systems, outcomes-oriented approach is timely, challenging, effective, and uplifting to the creative human spirit.
Field test of classical symmetric encryption with continuous variables quantum key distribution.
Jouguet, Paul; Kunz-Jacques, Sébastien; Debuisschert, Thierry; Fossier, Simon; Diamanti, Eleni; Alléaume, Romain; Tualle-Brouri, Rosa; Grangier, Philippe; Leverrier, Anthony; Pache, Philippe; Painchault, Philippe
2012-06-18
We report on the design and performance of a point-to-point classical symmetric encryption link with fast key renewal provided by a Continuous Variable Quantum Key Distribution (CVQKD) system. Our system was operational and able to encrypt point-to-point communications during more than six months, from the end of July 2010 until the beginning of February 2011. This field test was the first demonstration of the reliability of a CVQKD system over a long period of time in a server room environment. This strengthens the potential of CVQKD for information technology security infrastructure deployments.
Effect of two doses of ginkgo biloba extract (EGb 761) on the dual-coding test in elderly subjects.
Allain, H; Raoul, P; Lieury, A; LeCoz, F; Gandon, J M; d'Arbigny, P
1993-01-01
The subjects of this double-blind study were 18 elderly men and women (mean age, 69.3 years) with slight age-related memory impairment. In a crossover-study design, each subject received placebo or an extract of Ginkgo biloba (EGb 761) (320 mg or 600 mg) 1 hour before performing a dual-coding test that measures the speed of information processing; the test consists of several coding series of drawings and words presented at decreasing times of 1920, 960, 480, 240, and 120 ms. The dual-coding phenomenon (a break point between coding verbal material and images) was demonstrated in all the tests. After placebo, the break point was observed at 960 ms and dual coding beginning at 1920 ms. After each dose of the ginkgo extract, the break point (at 480 ms) and dual coding (at 960 ms) were significantly shifted toward a shorter presentation time, indicating an improvement in the speed of information processing.
MINOS Timing and GPS Precise Point Positioning
2012-01-01
Minos Timing Spec • Neutrinos created in bunches separated by 19 ns • ~ 1 neutrino/day detected in Soudan Mine – 2 milliseconds travel time...calibration – No low-cost Fermilab to Soudan Mine connections known – Not yet tested for operational time transfer Clock Options • High-Performance... UNDERGROUND LABORATORY •;, ~ (((ft.F ~’: · GPS PRECISE POINT POSITIONING A Brief Overview What is GPS PPP? • GPS PPP is a way to use precise ephemerides
Mohammadi, Zargham; Gharaat, Mohammad Javad; Field, Malcolm
2018-03-13
Tracer breakthrough curves provide valuable information about the traced media, especially in inherently heterogeneous karst aquifers. In order to study the effect of variations in hydraulic gradient and conduit systems on breakthrough curves, a bench scale karst model was constructed. The bench scale karst model contains both matrix and a conduit. Eight tracing tests were conducted under a wide range of hydraulic gradients from 1 to greater than 5 for branchwork and network-conduit systems. Sampling points at varying distances from the injection point were utilized. Results demonstrate that mean tracer velocities, tracer mass recovery and linear rising slope of the breakthrough curves were directly controlled by hydraulic gradient. As hydraulic gradient increased, both one half the time for peak concentration and one fifth the time for peak concentration decreased. The results demonstrate the variations in one half the time for peak concentration and one fifth the time for peak concentration of the descending limb for different sampling points under differing hydraulic gradients are mainly controlled by the interactions of advection with dispersion. The results are discussed from three perspectives: different conduit systems, different hydraulic-gradient conditions, and different sampling points. The research confirmed the undeniable role of hydrogeological setting (i.e., hydraulic gradient and conduit system) on the shape of the breakthrough curve. The extracted parameters (mobile-fluid velocity, tracer-mass recovery, linear rising limb, one half the time for peak concentration, and one fifth the time for peak concentration) allow for differentiating hydrogeological settings and enhance interpretations the tracing tests in karst aquifers. © 2018, National Ground Water Association.
Testing of the BipiColombo Antenna Pointing Mechanism
NASA Astrophysics Data System (ADS)
Campo, Pablo; Barrio, Aingeru; Martin, Fernando
2015-09-01
BepiColombo is an ESA mission to Mercury, its planetary orbiter (MPO) has two antenna pointing mechanism, High gain antenna (HGA) pointing mechanism steers and points a large reflector which is integrated at system level by TAS-I Rome. Medium gain antenna (MGA) APM points a 1.5 m boom with a horn antenna. Both radiating elements are exposed to sun fluxes as high as 10 solar constants without protections.A previous paper [1] described the design and development process to solve the challenges of performing in harsh environment.. Current paper is focused on the testing process of the qualification units. Testing performance of antenna pointing mechanism in its specific environmental conditions has required special set-up and techniques. The process has provided valuable feedback on the design and the testing methods which have been included in the PFM design and tests.Some of the technologies and components were developed on dedicated items priort to EQM, but once integrated, test behaviour had relevant differences.Some of the major concerns for the APM testing are:- Create during the thermal vacuum testing the qualification temperature map with gradients along the APM. From of 200oC to 70oC.- Test in that conditions the radio frequency and pointing performances adding also high RF power to check the power handling and self-heating of the rotary joint.- Test in life up to 12000 equivalent APM revolutions, that is 14.3 million motor revolutions in different thermal conditions.- Measure low thermal distortion of the mechanical chain, being at the same time insulated from external environment and interfaces (55 arcsec pointing error)- Perform deployment of large items guaranteeing during the process low humidity, below 5% to protect dry lubrication- Verify stability with representative inertia of large boom or reflector 20 Kgm2.
NASA Astrophysics Data System (ADS)
Miga, Michael I.; Weis, Jared A.; Granero-Molto, Froilan; Spagnoli, Anna
2010-03-01
Understanding bone remodeling and mechanical property characteristics is important for assessing treatments to accelerate healing or in developing diagnostics to evaluate successful return to function. The murine system whereby mid-diaphaseal tibia fractures are imparted on the subject and fracture healing is assessed at different time points and under different therapeutic conditions is a particularly useful model to study. In this work, a novel inverse geometric nonlinear elasticity modeling framework is proposed that can reconstruct multiple mechanical properties from uniaxial testing data. To test this framework, the Lame' constants were reconstructed within the context of a murine cohort (n=6) where there were no differences in treatment post tibia fracture except that half of the mice were allowed to heal 4 days longer (10 day, and 14 day healing time point, respectively). The properties reconstructed were a shear modulus of G=511.2 +/- 295.6 kPa, and 833.3+/- 352.3 kPa for the 10 day, and 14 day time points respectively. The second Lame' constant reconstructed at λ=1002.9 +/-42.9 kPa, and 14893.7 +/- 863.3 kPa for the 10 day, and 14 day time points respectively. An unpaired Student t-test was used to test for statistically significant differences among the groups. While the shear modulus did not meet our criteria for significance, the second Lame' constant did at a value p<0.0001. Traditional metrics that are commonly used within the bone fracture healing research community were not found to be statistically significant.
Ultra-Wideband Time-Difference-of-Arrival Two-Point-Tracking System
NASA Technical Reports Server (NTRS)
Ni, Jianjun David; Arndt, Dickey; Ngo, Phong; Phan, Chau; Dekome, Kent; Dusl, John
2009-01-01
A UWB TDOA Two-Point-Tracking System has been conceived and developed at JSC. This system can provide sub-inch tracking capability of two points on one target. This capability can be applied to guide a docking process in a 2D space. Lab tests demonstrate the feasibility of this technology.
A Parallel Point Matching Algorithm for Landmark Based Image Registration Using Multicore Platform
Yang, Lin; Gong, Leiguang; Zhang, Hong; Nosher, John L.; Foran, David J.
2013-01-01
Point matching is crucial for many computer vision applications. Establishing the correspondence between a large number of data points is a computationally intensive process. Some point matching related applications, such as medical image registration, require real time or near real time performance if applied to critical clinical applications like image assisted surgery. In this paper, we report a new multicore platform based parallel algorithm for fast point matching in the context of landmark based medical image registration. We introduced a non-regular data partition algorithm which utilizes the K-means clustering algorithm to group the landmarks based on the number of available processing cores, which optimize the memory usage and data transfer. We have tested our method using the IBM Cell Broadband Engine (Cell/B.E.) platform. The results demonstrated a significant speed up over its sequential implementation. The proposed data partition and parallelization algorithm, though tested only on one multicore platform, is generic by its design. Therefore the parallel algorithm can be extended to other computing platforms, as well as other point matching related applications. PMID:24308014
Gibson, Jane; Schechter-Perkins, Elissa M; Mitchell, Patricia; Mace, Sharon; Tian, Yu; Williams, Kemi; Luo, Robert; Yen-Lieberman, Belinda
2017-10-01
Point of Care Testing (POCT) provides the capability for rapid laboratory test results in patient care environments where a traditional clinical laboratory is not available. POCTs have shorter turn-around times (TATs), they may be performed by non-laboratory personnel, and the need for transport time is eliminated. The Food and Drug Administration (FDA) recently granted Clinical Laboratory Improvements Amendment (CLIA) waiver status to the cobas ® Influenza A/B & RSV assay, a rapid, accurate point-of-care test for Influenza and respiratory syncytial virus (RSV) performed on the Liat ® System. The performance characteristics of this test were determined though a multi-site study consisting of different point of care testing environments. Prospectively collected Nasopharyngeal (NP) swabs from 1361 patients seen at 8 primary care clinics and 4 emergency departments (EDs) and 295 retrospectively identified specimens were tested for Influenza A/B and RSV on the cobas ® Liat ® platform. Performance characteristics were determined through comparison to ProFlu+, a laboratory-based PCR test for Influenza A/B and RSV (reference test). Discordant specimens were adjudicated following bi-directional sequencing. The cobas ® Influenza A/B and RSV assay showed sensitivities of 99.6%, 99.3%, and 96.8% for Influenza A, Influenza B, and RSV, respectively as determined from percent positive agreement (PPA) following comparison to the reference test. Sequencing confirmed cobas ® Influenza A/B and RSV results in 49.2% of reference test discordant specimens, while crossing threshold data suggest increased sensitivity compared to the reference test. The cobas ® Influenza A/B and RSV assay was found to be a rapid, sensitive POCT for the detection of these viruses, and provides laboratory-quality PCR-based diagnostic results in point of care settings. Copyright © 2017 Elsevier B.V. All rights reserved.
Nikamp, Corien Dm; Buurke, Jaap H; van der Palen, Job; Hermens, Hermie J; Rietman, Johan S
2017-06-01
(1) To study the effects of providing ankle-foot orthoses in subjects with (sub)acute stroke; and (2) to study whether the point in time at which an ankle-foot orthosis is provided post-stroke (early or delayed) influences these effects. Randomized controlled trial. Rehabilitation centre. Unilateral hemiparetic stroke subjects with indication for use of an ankle-foot orthosis and maximal six weeks post-stroke. Subjects were randomly assigned to: early provision (at inclusion; Week 1) or delayed provision (eight weeks later; Week 9). 10-metre walk test, 6-minute walk test, Timed Up and Go Test, stairs test, Functional Ambulation Categories, Berg Balance Scale, Rivermead Mobility Index and Barthel Index; assessed in Weeks 1, 3, 9 and 11. A total of 33 subjects were randomized (16 early, 17 delayed). Positive effects of ankle-foot orthoses were found two weeks after provision, both when provided early (significant effects on all outcomes) or delayed (Berg Balance Scale p = 0.011, Functional Ambulation Categories p = 0.008, 6-minute walk test p = 0.005, Timed Up and Go Test p = 0.028). Comparing effects after early and delayed provision showed that early provision resulted in increased levels of improvement on Berg Balance Scale (+5.1 points, p = 0.002), Barthel Index (+1.9 points, p = 0.002) and non-significant improvements on 10-metre walk test (+0.14 m/s, p = 0.093) and Timed Up and Go Test (-5.4 seconds, p = 0.087), compared with delayed provision. We found positive effects of providing ankle-foot orthoses in (sub)acute stroke subjects that had not used these orthoses before.
Efficacy of Several Therapeutic Agents in a Murine Model of Dry Eye Syndrome
Kilic, Servet; Kulualp, Kadri
2016-01-01
In the current study, we used 56 female BALB/c mice with induced dry eye syndrome to evaluate the therapeutic effects of formal saline (FS), sodium hyaluronate (SH), diclofenac sodium (DS), olopatadine (OP), retinoic acid (RA), fluoromethanole (FML), cyclosporine A (CsA), and doxycycline hyclate (DH). All subjects were kept in an evaporative ‘dry eye cabinet’ for the assessment of blink rate, tear production, tear break-up time, and impression cytology prior to (baseline) and during weeks 2, 4, and 6 of the study. The right eyes of all subjects were treated topically with 5 µL of the test agent twice daily during weeks 2 through 6. Impression cytology and tear break-up time differed between time points in all groups and differed between groups at weeks 4 and 6. Blink rate differed by time point only in the FS, FML, and DH groups. Tear production according to the phenol red cotton thread test differed by time point for all groups except RA, CsA, and DH and differed between groups only at week 6. Among the compounds tested in the present study, DS and CsA were the most effective therapeutic agents in our mouse model of dry eye syndrome; these agents likely exert their therapeutic effect through their antiinflammatory activity. PMID:27053565
On the importance of developing a new generation of breath tests for Helicobacter pylori detection.
Kushch, Ievgeniia; Korenev, Nikolai; Kamarchuk, Lyudmila; Pospelov, Alexander; Kravchenko, Andrey; Bajenov, Leonid; Kabulov, Mels; Amann, Anton; Kamarchuk, Gennadii
2015-12-15
State-of-the-art methods for non-invasive detection of the Helicobacter pylori (H. pylori) infection have been considered. A reported global tendency towards a non-decreasing prevalence of H. pylori worldwide could be co-influenced by the functional limitations of urea breath tests (UBTs), currently preferred for the non-invasive recognition of H. pylori in a clinical setting. Namely, the UBTs can demonstrate false-positive or false-negative results. Within this context, limitations of conventional clinically exploited H. pylori tests have been discussed to justify the existing need for the development of a new generation of breath tests for the detection of H. pylori and the differentiation of pathogenic and non-pathogenic strains of the bacterium. This paper presents the results of a pilot clinical study aimed at evaluating the development and diagnostic potential of a new method based on the detection of the non-urease products of H. pylori vital activity in exhaled gas. The characteristics of breath of adolescents with H. pylori-positive and H. pylori-negative functional dyspepsia, together with a consideration of the cytotoxin-associated gene A (CagA) status of H. pylori-positive subjects, have been determined for the first time using innovative point-contact nanosensor devices based on salts of the organic conductor tetracyanoquinodimethane (TCNQ). The clinical and diagnostic relevance of the response curves of the point-contact sensors was assessed. It was found that the recovery time of the point-contact sensors has a diagnostic value for differentiation of the H. pylori-associated peptic ulcer disease. The diagnostically significant elongation of the recovery time was even more pronounced in patients infected with CagA-positive H. pylori strains compared to the CagA-negative patients. Taking into account the operation of the point-contact sensors in the real-time mode, the obtained results are essential prerequisites for the development of a fast and portable breath test for non-invasive detection of cytotoxic CagA strains of H. pylori infection. The relaxation time of the point-contact nanosensors could be selected as a diagnostic criterion for non-invasive determination of H. pylori-associated destructive lesions of the gastroduodenal area in adolescents, using the point-contact spectroscopic concept of breath analysis. This can subsequently be implemented into a 'test-and-treat' approach for the management of uninvestigated dyspepsia in populations with a high prevalence of H. pylori (according to the Maastricht III and IV Consensus recommendations).
Khosrow-Khavar, Farzad; Tavakolian, Kouhyar; Blaber, Andrew; Menon, Carlo
2016-10-12
The purpose of this research was to design a delineation algorithm that could detect specific fiducial points of the seismocardiogram (SCG) signal with or without using the electrocardiogram (ECG) R-wave as the reference point. The detected fiducial points were used to estimate cardiac time intervals. Due to complexity and sensitivity of the SCG signal, the algorithm was designed to robustly discard the low-quality cardiac cycles, which are the ones that contain unrecognizable fiducial points. The algorithm was trained on a dataset containing 48,318 manually annotated cardiac cycles. It was then applied to three test datasets: 65 young healthy individuals (dataset 1), 15 individuals above 44 years old (dataset 2), and 25 patients with previous heart conditions (dataset 3). The algorithm accomplished high prediction accuracy with the rootmean- square-error of less than 5 ms for all the test datasets. The algorithm overall mean detection rate per individual recordings (DRI) were 74, 68, and 42 percent for the three test datasets when concurrent ECG and SCG were used. For the standalone SCG case, the mean DRI was 32, 14 and 21 percent. When the proposed algorithm applied to concurrent ECG and SCG signals, the desired fiducial points of the SCG signal were successfully estimated with a high detection rate. For the standalone case, however, the algorithm achieved high prediction accuracy and detection rate for only the young individual dataset. The presented algorithm could be used for accurate and non-invasive estimation of cardiac time intervals.
NASA Technical Reports Server (NTRS)
Dickinson, D.; Hicks, F.; Schlemmer, J.; Michel, F.; Moog, R. D.
1972-01-01
The pertinent events concerned with the launch, float, and flight of balloon launched decelerator test vehicle AV-2 are discussed. The performance of the decelerator system is analyzed. Data on the flight trajectory and decelerator test points at the time of decelerator deployment are provided. A description of the time history of vehicle events and anomalies encounters during the mission is included.
NASA Technical Reports Server (NTRS)
Dickinson, D.; Hicks, F.; Schlemmer, J.; Michel, F.; Moog, R. D.
1973-01-01
The pertinent events concerned with the launch, float, and flight of balloon launched decelerator test vehicle AV-3 are discussed. The performance of the decelerator system is analyzed. Data on the flight trajectory and decelerator test points at the time of decelerator deployment are provided. A description of the time history of vehicle events and anaomalies encounters during the mission is included.
International Aviation (Selected Articles)
1991-09-11
THE ANAYLYSIS OF DYNAMIC FORCES IN AVIATION STRUCTURES Following along with the development of test manufacturing projects for many types of aircraft...type water troughs. All the main equipment embodies automated measurement controls. It is capable of obtaining test data and curves in a real time...results from thousands of calculations, and decisions were made to select the imaginary origin point to act as the turbulence flow origination point
ERIC Educational Resources Information Center
Group of Eight (NJ1), 2010
2010-01-01
The Group of Eight (Go8) applauds the government's intention to comprehensively reform the skilled migration program, and it welcomes the opportunity to submit this response to the General Skilled Migration (GSM) Points Test Discussion Paper. The Go8 has argued for some time that it is inappropriate to link international education to the skilled…
77 FR 15813 - Preoperational Testing of Instrument and Control Air Systems
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-16
... seismic requirement, ICAS air-dryer testing to meet dew point design requirements, ICAS accumulator check... ensure consideration only for comments received on or before this date. Although a time limit is given... improvements in all published guides are encouraged at any time. ADDRESSES: You may access information and...
A new method of real-time detection of changes in periodic data stream
NASA Astrophysics Data System (ADS)
Lyu, Chen; Lu, Guoliang; Cheng, Bin; Zheng, Xiangwei
2017-07-01
The change point detection in periodic time series is much desirable in many practical usages. We present a novel algorithm for this task, which includes two phases: 1) anomaly measure- on the basis of a typical regression model, we propose a new computation method to measure anomalies in time series which does not require any reference data from other measurement(s); 2) change detection- we introduce a new martingale test for detection which can be operated in an unsupervised and nonparametric way. We have conducted extensive experiments to systematically test our algorithm. The results make us believe that our algorithm can be directly applicable in many real-world change-point-detection applications.
Hypothesis testing of a change point during cognitive decline among Alzheimer's disease patients.
Ji, Ming; Xiong, Chengjie; Grundman, Michael
2003-10-01
In this paper, we present a statistical hypothesis test for detecting a change point over the course of cognitive decline among Alzheimer's disease patients. The model under the null hypothesis assumes a constant rate of cognitive decline over time and the model under the alternative hypothesis is a general bilinear model with an unknown change point. When the change point is unknown, however, the null distribution of the test statistics is not analytically tractable and has to be simulated by parametric bootstrap. When the alternative hypothesis that a change point exists is accepted, we propose an estimate of its location based on the Akaike's Information Criterion. We applied our method to a data set from the Neuropsychological Database Initiative by implementing our hypothesis testing method to analyze Mini Mental Status Exam scores based on a random-slope and random-intercept model with a bilinear fixed effect. Our result shows that despite large amount of missing data, accelerated decline did occur for MMSE among AD patients. Our finding supports the clinical belief of the existence of a change point during cognitive decline among AD patients and suggests the use of change point models for the longitudinal modeling of cognitive decline in AD research.
Point-of-Care Test Equipment for Flexible Laboratory Automation.
You, Won Suk; Park, Jae Jun; Jin, Sung Moon; Ryew, Sung Moo; Choi, Hyouk Ryeol
2014-08-01
Blood tests are some of the core clinical laboratory tests for diagnosing patients. In hospitals, an automated process called total laboratory automation, which relies on a set of sophisticated equipment, is normally adopted for blood tests. Noting that the total laboratory automation system typically requires a large footprint and significant amount of power, slim and easy-to-move blood test equipment is necessary for specific demands such as emergency departments or small-size local clinics. In this article, we present a point-of-care test system that can provide flexibility and portability with low cost. First, the system components, including a reagent tray, dispensing module, microfluidic disk rotor, and photometry scanner, and their functions are explained. Then, a scheduler algorithm to provide a point-of-care test platform with an efficient test schedule to reduce test time is introduced. Finally, the results of diagnostic tests are presented to evaluate the system. © 2014 Society for Laboratory Automation and Screening.
Confidence intervals for the first crossing point of two hazard functions.
Cheng, Ming-Yen; Qiu, Peihua; Tan, Xianming; Tu, Dongsheng
2009-12-01
The phenomenon of crossing hazard rates is common in clinical trials with time to event endpoints. Many methods have been proposed for testing equality of hazard functions against a crossing hazards alternative. However, there has been relatively few approaches available in the literature for point or interval estimation of the crossing time point. The problem of constructing confidence intervals for the first crossing time point of two hazard functions is considered in this paper. After reviewing a recent procedure based on Cox proportional hazard modeling with Box-Cox transformation of the time to event, a nonparametric procedure using the kernel smoothing estimate of the hazard ratio is proposed. The proposed procedure and the one based on Cox proportional hazard modeling with Box-Cox transformation of the time to event are both evaluated by Monte-Carlo simulations and applied to two clinical trial datasets.
Turning Points during the Life of Student Project Teams: A Qualitative Study
ERIC Educational Resources Information Center
Raes, Elisabeth; Kyndt, Eva; Dochy, Filip
2015-01-01
In this qualitative study a more flexible alternative of conceptualising changes over time in teams is tested within student project teams. The conceptualisation uses turning points during the lifespan of a team to outline team development, based on work by Erbert, Mearns, & Dena (2005). Turning points are moments that made a significant…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roper, J; Bradshaw, B; Godette, K
Purpose: To create a knowledge-based algorithm for prostate LDR brachytherapy treatment planning that standardizes plan quality using seed arrangements tailored to individual physician preferences while being fast enough for real-time planning. Methods: A dataset of 130 prior cases was compiled for a physician with an active prostate seed implant practice. Ten cases were randomly selected to test the algorithm. Contours from the 120 library cases were registered to a common reference frame. Contour variations were characterized on a point by point basis using principle component analysis (PCA). A test case was converted to PCA vectors using the same process andmore » then compared with each library case using a Mahalanobis distance to evaluate similarity. Rank order PCA scores were used to select the best-matched library case. The seed arrangement was extracted from the best-matched case and used as a starting point for planning the test case. Computational time was recorded. Any subsequent modifications were recorded that required input from a treatment planner to achieve an acceptable plan. Results: The computational time required to register contours from a test case and evaluate PCA similarity across the library was approximately 10s. Five of the ten test cases did not require any seed additions, deletions, or moves to obtain an acceptable plan. The remaining five test cases required on average 4.2 seed modifications. The time to complete manual plan modifications was less than 30s in all cases. Conclusion: A knowledge-based treatment planning algorithm was developed for prostate LDR brachytherapy based on principle component analysis. Initial results suggest that this approach can be used to quickly create treatment plans that require few if any modifications by the treatment planner. In general, test case plans have seed arrangements which are very similar to prior cases, and thus are inherently tailored to physician preferences.« less
Integrating Point-of-Care Testing into a Community Emergency Department: A Mixed-Methods Evaluation.
Pines, Jesse M; Zocchi, Mark S; Carter, Caitlin; Marriott, Charles Z; Bernard, Matthew; Warner, Leah H
2018-05-13
Point-of-care testing (POCT) is a commonly used technology that hastens the time to laboratory results in emergency departments (ED). We evaluated an ED-based POCT program on ED length of stay and time to care, coupled with qualitative interviews of local ED stakeholders. We conducted a mixed-methods study (2012-16) to examine the impact of point-of-care testing in a single, community ED. The quantiative analysis involved an observational before-after study comparing time to laboratory test result (POC troponin or POC chemistry) and ED length of stay after implementation of POCT, using a propensity-weighted interrupted time series analysis (ITSA). A complementary qualitative analysis involved five semi-structured interviews with staff using grounded theory on the benefits and challenges to ED POCT. A total of 47,399 ED visits were included in the study (24,705 in pre-intervention period and 22,694 in post-intervention). After POCT implementation, overall laboratory testing increased marginally from 61 to 62%. Central laboratory troponin and chemistry declined by >50% and was replaced by POCT. Prior to POCT implementation, time to troponin and chemistry had declined steadily due to other improvements in laboratory efficiency. After POCT implementation, there was an immediate 20 minute further decline (p<0.001) in both time to troponin and time to chemistry results using the propensity-weighted comparisons. However, the declining trend observed prior to POCT implementation did not continue at the same rate post implementation. Similarly, prior to POCT implementation, ED length of stay (LOS) declined due to other quality improvements. After POCT implementation, LOS continued declined at a similar rate. Because of this prior trend, the ITSA did not show a significant decline in LOS attributable to POCT. Common benefits of POCT perceived by staff in qualitative interviews included improved quality of care (64%), and reductions in time to test results (44%). Common challenges included concerns over POCT accuracy (32%), and technical barriers (29%). In the study ED, implementation of POCT was associated with a reduction in time to test result for both troponin and chemistry. Local staff felt that faster time to test result improved quality of care; however, concerns were raised with POCT accuracy. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Using permutations to detect dependence between time series
NASA Astrophysics Data System (ADS)
Cánovas, Jose S.; Guillamón, Antonio; Ruíz, María del Carmen
2011-07-01
In this paper, we propose an independence test between two time series which is based on permutations. The proposed test can be carried out by means of different common statistics such as Pearson’s chi-square or the likelihood ratio. We also point out why an exact test is necessary. Simulated and real data (return exchange rates between several currencies) reveal the capacity of this test to detect linear and nonlinear dependences.
NASA Astrophysics Data System (ADS)
Lopez, Benjamin; Baran, Nicole; Bourgine, Bernard
2015-03-01
The European Water Framework Directive (WFD) asks Member States to identify trends in contaminant concentrations in groundwater and to take measures to reach a good chemical status by 2015. In this study, carried out in a large hydrological basin (95,300 km2), an innovative procedure is described for the assessment of recent trends in groundwater nitrate concentrations both at sampling point and regional scales. Temporal variograms of piezometric and nitrate concentration time series are automatically calculated and fitted in order to classify groundwater according to their temporal pattern. These results are then coupled with aquifer lithology to map spatial units within which the modes of diffuse transport of contaminants towards groundwater are assumed to be the same at all points. These spatial units are suitable for evaluating regional trends. The stability over time of the time series is tested based on the cumulative sum principle, to determine the time period during which the trend should be sought. The Mann-Kendall and Regional-Kendall nonparametric tests for monotonic trends, coupled with the Sen-slope test, are applied to the periods following the point breaks thus determined at both the sampling point or regional scales. This novel procedure is robust and enables rapid processing of large databases of raw data. It would therefore be useful for managing groundwater quality in compliance with the aims of the WFD.
ERIC Educational Resources Information Center
Bohanon, Hank; Fenning, Pamela; Hicks, Kira; Weber, Stacey; Thier, Kimberly; Aikins, Brigit; Morrissey, Kelly; Briggs, Alissa; Bartucci, Gina; McArdle, Lauren; Hoeper, Lisa; Irvin, Larry
2012-01-01
The purpose of this case study was to expand the literature base regarding the application of high school schoolwide positive behavior support in an urban setting for practitioners and policymakers to address behavior issues. In addition, the study describes the use of the Change Point Test as a method for analyzing time series data that are…
ERIC Educational Resources Information Center
Rock, Donald; Werts, Charles
The purpose of this study was to obtain information on both the number of individuals who retest and their patterns of score gain (or decrement) by sex and ability. Individuals who retested only once were found to gain about 26-27 points on the Graduate Record Examination (GRE) verbal test and about 23 points on the GRE quantitative test. This…
NASA Astrophysics Data System (ADS)
Zhang, Zaixuan; Wang, Kequan; Kim, Insoo S.; Wang, Jianfeng; Feng, Haiqi; Guo, Ning; Yu, Xiangdong; Zhou, Bangquan; Wu, Xiaobiao; Kim, Yohee
2000-05-01
The DOFTS system that has applied to temperature automatically alarm system of coal mine and tunnel has been researched. It is a real-time, on line and multi-point measurement system. The wavelength of LD is 1550 nm, on the 6 km optical fiber, 3000 points temperature signal is sampled and the spatial position is certain. Temperature measured region: -50 degree(s)C--100 degree(s)C; measured uncertain value: +/- 3 degree(s)C; temperature resolution: 0.1 degree(s)C; spatial resolution: <5 cm (optical fiber sensor probe); <8 m (spread optical fiber); measured time: <70 s. In the paper, the operated principles, underground test, test content and practical test results have been discussed.
Detecting Abrupt Changes in a Piecewise Locally Stationary Time Series
Last, Michael; Shumway, Robert
2007-01-01
Non-stationary time series arise in many settings, such as seismology, speech-processing, and finance. In many of these settings we are interested in points where a model of local stationarity is violated. We consider the problem of how to detect these change-points, which we identify by finding sharp changes in the time-varying power spectrum. Several different methods are considered, and we find that the symmetrized Kullback-Leibler information discrimination performs best in simulation studies. We derive asymptotic normality of our test statistic, and consistency of estimated change-point locations. We then demonstrate the technique on the problem of detecting arrival phases in earthquakes. PMID:19190715
Normanno, Nicola; Pinto, Carmine; Taddei, Gianluigi; Gambacorta, Marcello; Castiglione, Francesca; Barberis, Massimo; Clemente, Claudio; Marchetti, Antonio
2013-06-01
The Italian Association of Medical Oncology (AIOM) and the Italian Society of Pathology and Cytology organized an external quality assessment (EQA) scheme for EGFR mutation testing in non-small-cell lung cancer. Ten specimens, including three small biopsies with known epidermal growth factor receptor (EGFR) mutation status, were validated in three referral laboratories and provided to 47 participating centers. The participants were requested to perform mutational analysis, using their usual method, and to submit results within a 4-week time frame. According to a predefined scoring system, two points were assigned to correct genotype and zero points to false-negative or false-positive results. The threshold to pass the EQA was set at higher than 18 of 20 points. Two rounds were preplanned. All participating centers submitted the results within the time frame. Polymerase chain reaction (PCR)/sequencing was the main methodology used (n = 37 laboratories), although a few centers did use pyrosequencing (n = 8) or real-time PCR (n = 2). A significant number of analytical errors were observed (n = 20), with a high frequency of false-positive results (n = 16). The lower scores were obtained for the small biopsies. Fourteen of 47 centers (30%) that did not pass the first round, having a score less than or equal to 18 points, used PCR/sequencing, whereas 10 of 10 laboratories, using pyrosequencing or real-time PCR, passed the first round. Eight laboratories passed the second round. Overall, 41of 47 centers (87%) passed the EQA. The results of the EQA for EGFR testing in non-small-cell lung cancer suggest that good quality EGFR mutational analysis is performed in Italian laboratories, although differences between testing methods were observed, especially for small biopsies.
Putting New Laboratory Tests Into Practice
... Time and International Normalized Ratio (PT/INR) PSEN1 Quantitative Immunoglobulins Red Blood Cell (RBC) Antibody Identification Red ... a particular test that shows promise in the research stages actually get to the point where it ...
Banda, Jorge A; Haydel, K Farish; Davila, Tania; Desai, Manisha; Bryson, Susan; Haskell, William L; Matheson, Donna; Robinson, Thomas N
2016-01-01
To examine the effects of accelerometer epoch lengths, wear time (WT) algorithms, and activity cut-points on estimates of WT, sedentary behavior (SB), and physical activity (PA). 268 7-11 year-olds with BMI ≥ 85th percentile for age and sex wore accelerometers on their right hips for 4-7 days. Data were processed and analyzed at epoch lengths of 1-, 5-, 10-, 15-, 30-, and 60-seconds. For each epoch length, WT minutes/day was determined using three common WT algorithms, and minutes/day and percent time spent in SB, light (LPA), moderate (MPA), and vigorous (VPA) PA were determined using five common activity cut-points. ANOVA tested differences in WT, SB, LPA, MPA, VPA, and MVPA when using the different epoch lengths, WT algorithms, and activity cut-points. WT minutes/day varied significantly by epoch length when using the NHANES WT algorithm (p < .0001), but did not vary significantly by epoch length when using the ≥ 20 minute consecutive zero or Choi WT algorithms. Minutes/day and percent time spent in SB, LPA, MPA, VPA, and MVPA varied significantly by epoch length for all sets of activity cut-points tested with all three WT algorithms (all p < .0001). Across all epoch lengths, minutes/day and percent time spent in SB, LPA, MPA, VPA, and MVPA also varied significantly across all sets of activity cut-points with all three WT algorithms (all p < .0001). The common practice of converting WT algorithms and activity cut-point definitions to match different epoch lengths may introduce significant errors. Estimates of SB and PA from studies that process and analyze data using different epoch lengths, WT algorithms, and/or activity cut-points are not comparable, potentially leading to very different results, interpretations, and conclusions, misleading research and public policy.
Geerse, Daphne J; Coolen, Bert H; Roerdink, Melvyn
2015-01-01
Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatch-based time to walk 10 meters with quantitative gait information derived from Kinect's 3D body point's time series. The current study aimed to evaluate a multi-Kinect v2 set-up for quantitative gait assessments during the 10MWT against a gold-standard motion-registration system by determining between-systems agreement for body point's time series, spatiotemporal gait parameters and the time to walk 10 meters. To this end, the 10MWT was conducted at comfortable and maximum walking speed, while 3D full-body kinematics was concurrently recorded with the multi-Kinect v2 set-up and the Optotrak motion-registration system (i.e., the gold standard). Between-systems agreement for body point's time series was assessed with the intraclass correlation coefficient (ICC). Between-systems agreement was similarly determined for the gait parameters' walking speed, cadence, step length, stride length, step width, step time, stride time (all obtained for the intermediate 6 meters) and the time to walk 10 meters, complemented by Bland-Altman's bias and limits of agreement. Body point's time series agreed well between the motion-registration systems, particularly so for body points in motion. For both comfortable and maximum walking speeds, the between-systems agreement for the time to walk 10 meters and all gait parameters except step width was high (ICC ≥ 0.888), with negligible biases and narrow limits of agreement. Hence, body point's time series and gait parameters obtained with a multi-Kinect v2 set-up match well with those derived with a gold standard in 3D measurement accuracy. Future studies are recommended to test the clinical utility of the multi-Kinect v2 set-up to automate 10MWT assessments, thereby complementing the time to walk 10 meters with reliable spatiotemporal gait parameters obtained objectively in a quick, unobtrusive and patient-friendly manner.
Testing the Predictive Validity of the Hendrich II Fall Risk Model.
Jung, Hyesil; Park, Hyeoun-Ae
2018-03-01
Cumulative data on patient fall risk have been compiled in electronic medical records systems, and it is possible to test the validity of fall-risk assessment tools using these data between the times of admission and occurrence of a fall. The Hendrich II Fall Risk Model scores assessed during three time points of hospital stays were extracted and used for testing the predictive validity: (a) upon admission, (b) when the maximum fall-risk score from admission to falling or discharge, and (c) immediately before falling or discharge. Predictive validity was examined using seven predictive indicators. In addition, logistic regression analysis was used to identify factors that significantly affect the occurrence of a fall. Among the different time points, the maximum fall-risk score assessed between admission and falling or discharge showed the best predictive performance. Confusion or disorientation and having a poor ability to rise from a sitting position were significant risk factors for a fall.
The effects of fundus photography on the multifocal electroretinogram.
Suresh, Sandip; Tienor, Brian J; Smith, Scott D; Lee, Michael S
2016-02-01
To determine the effect of flash fundus photography (FFP) on the multifocal electroretinogram (mfERG). Ten subjects underwent mfERG testing on three separate dates. Subjects received either mfERG without FFP, mfERG at 5 and 15 min after FFP, or mfERG at 30 and 45 min after FFP on each date. The FFP groups received 10 fundus photographs followed by mfERG testing, first of the right eye then of the left eye 10 min later. Data were averaged and analyzed in six concentric rings at each time point. Average amplitude and implicit times of the N1, P1, and N2 peaks for each concentric ring at each time point after FFP were compared to baseline. Flash fundus photography did not lead to a significant change of amplitude or implicit times of N1, P1, or N2 at 5 min after light exposure. These findings suggest that it is acceptable to perform mfERG testing without delay after performance of FFP.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jung, Yoojin; Han, Byunghyun; Mostafid, M. Erfan
2012-02-15
Highlights: Black-Right-Pointing-Pointer Photoacoustic infrared spectroscopy tested for measuring tracer gas in landfills. Black-Right-Pointing-Pointer Measurement errors for tracer gases were 1-3% in landfill gas. Black-Right-Pointing-Pointer Background signals from landfill gas result in elevated limits of detection. Black-Right-Pointing-Pointer Technique is much less expensive and easier to use than GC. - Abstract: Gas tracer tests can be used to determine gas flow patterns within landfills, quantify volatile contaminant residence time, and measure water within refuse. While gas chromatography (GC) has been traditionally used to analyze gas tracers in refuse, photoacoustic spectroscopy (PAS) might allow real-time measurements with reduced personnel costs and greater mobilitymore » and ease of use. Laboratory and field experiments were conducted to evaluate the efficacy of PAS for conducting gas tracer tests in landfills. Two tracer gases, difluoromethane (DFM) and sulfur hexafluoride (SF{sub 6}), were measured with a commercial PAS instrument. Relative measurement errors were invariant with tracer concentration but influenced by background gas: errors were 1-3% in landfill gas but 4-5% in air. Two partitioning gas tracer tests were conducted in an aerobic landfill, and limits of detection (LODs) were 3-4 times larger for DFM with PAS versus GC due to temporal changes in background signals. While higher LODs can be compensated by injecting larger tracer mass, changes in background signals increased the uncertainty in measured water saturations by up to 25% over comparable GC methods. PAS has distinct advantages over GC with respect to personnel costs and ease of use, although for field applications GC analyses of select samples are recommended to quantify instrument interferences.« less
Brazzale, Alessandra R; Küchenhoff, Helmut; Krügel, Stefanie; Schiergens, Tobias S; Trentzsch, Heiko; Hartl, Wolfgang
2018-04-05
We present a new method for estimating a change point in the hazard function of a survival distribution assuming a constant hazard rate after the change point and a decreasing hazard rate before the change point. Our method is based on fitting a stump regression to p values for testing hazard rates in small time intervals. We present three real data examples describing survival patterns of severely ill patients, whose excess mortality rates are known to persist far beyond hospital discharge. For designing survival studies in these patients and for the definition of hospital performance metrics (e.g. mortality), it is essential to define adequate and objective end points. The reliable estimation of a change point will help researchers to identify such end points. By precisely knowing this change point, clinicians can distinguish between the acute phase with high hazard (time elapsed after admission and before the change point was reached), and the chronic phase (time elapsed after the change point) in which hazard is fairly constant. We show in an extensive simulation study that maximum likelihood estimation is not robust in this setting, and we evaluate our new estimation strategy including bootstrap confidence intervals and finite sample bias correction.
EOS-AM precision pointing verification
NASA Technical Reports Server (NTRS)
Throckmorton, A.; Braknis, E.; Bolek, J.
1993-01-01
The Earth Observing System (EOS) AM mission requires tight pointing knowledge to meet scientific objectives, in a spacecraft with low frequency flexible appendage modes. As the spacecraft controller reacts to various disturbance sources and as the inherent appendage modes are excited by this control action, verification of precision pointing knowledge becomes particularly challenging for the EOS-AM mission. As presently conceived, this verification includes a complementary set of multi-disciplinary analyses, hardware tests and real-time computer in the loop simulations, followed by collection and analysis of hardware test and flight data and supported by a comprehensive data base repository for validated program values.
Non-Linear Harmonic flow simulations of a High-Head Francis Turbine test case
NASA Astrophysics Data System (ADS)
Lestriez, R.; Amet, E.; Tartinville, B.; Hirsch, C.
2016-11-01
This work investigates the use of the non-linear harmonic (NLH) method for a high- head Francis turbine, the Francis99 workshop test case. The NLH method relies on a Fourier decomposition of the unsteady flow components in harmonics of Blade Passing Frequencies (BPF), which are the fundamentals of the periodic disturbances generated by the adjacent blade rows. The unsteady flow solution is obtained by marching in pseudo-time to a steady-state solution of the transport equations associated with the time-mean, the BPFs and their harmonics. Thanks to this transposition into frequency domain, meshing only one blade channel is sufficient, like for a steady flow simulation. Notable benefits in terms of computing costs and engineering time can therefore be obtained compared to classical time marching approach using sliding grid techniques. The method has been applied for three operating points of the Francis99 workshop high-head Francis turbine. Steady and NLH flow simulations have been carried out for these configurations. Impact of the grid size and near-wall refinement is analysed on all operating points for steady simulations and for Best Efficiency Point (BEP) for NLH simulations. Then, NLH results for a selected grid size are compared for the three different operating points, reproducing the tendencies observed in the experiment.
NASA Astrophysics Data System (ADS)
Xu, Y.; Sun, Z.; Boerner, R.; Koch, T.; Hoegner, L.; Stilla, U.
2018-04-01
In this work, we report a novel way of generating ground truth dataset for analyzing point cloud from different sensors and the validation of algorithms. Instead of directly labeling large amount of 3D points requiring time consuming manual work, a multi-resolution 3D voxel grid for the testing site is generated. Then, with the help of a set of basic labeled points from the reference dataset, we can generate a 3D labeled space of the entire testing site with different resolutions. Specifically, an octree-based voxel structure is applied to voxelize the annotated reference point cloud, by which all the points are organized by 3D grids of multi-resolutions. When automatically annotating the new testing point clouds, a voting based approach is adopted to the labeled points within multiple resolution voxels, in order to assign a semantic label to the 3D space represented by the voxel. Lastly, robust line- and plane-based fast registration methods are developed for aligning point clouds obtained via various sensors. Benefiting from the labeled 3D spatial information, we can easily create new annotated 3D point clouds of different sensors of the same scene directly by considering the corresponding labels of 3D space the points located, which would be convenient for the validation and evaluation of algorithms related to point cloud interpretation and semantic segmentation.
Platelet-activated clotting time does not measure platelet reactivity during cardiac surgery.
Shore-Lesserson, L; Ammar, T; DePerio, M; Vela-Cantos, F; Fisher, C; Sarier, K
1999-08-01
Platelet dysfunction is a major contributor to bleeding after cardiopulmonary bypass (CPB), yet it remains difficult to diagnose. A point-of-care monitor, the platelet-activated clotting time (PACT), measures accelerated shortening of the kaolin-activated clotting time by addition of platelet activating factor. The authors sought to evaluate the clinical utility of the PACT by conducting serial measurements of PACT during cardiac surgery and correlating postoperative measurements with blood loss. In 50 cardiac surgical patients, blood was sampled at 10 time points to measure PACT. Simultaneously, platelet reactivity was measured by the thrombin receptor agonist peptide-induced expression of P-selectin, using flow cytometry. These tests were temporally analyzed. PACT values, P-selectin expression, and other coagulation tests were analyzed for correlation with postoperative chest tube drainage. PACT and P-selectin expression were maximally reduced after protamine administration. Changes in PACT did not correlate with changes in P-selectin expression at any time interval. Total 8-h chest tube drainage did not correlate with any coagulation test at any time point except with P-selectin expression after protamine administration (r = -0.4; P = 0.03). The platelet dysfunction associated with CPB may be a result of depressed platelet reactivity, as shown by thrombin receptor activating peptide-induced P-selectin expression. Changes in PACT did not correlate with blood loss or with changes in P-selectin expression suggesting that PACT is not a specific measure of platelet reactivity.
40 CFR 86.535-90 - Dynamometer procedure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... run consists of two tests, a “cold” start test and a “hot” start test following the “cold” start by 10... Administrator. (d) Practice runs over the prescribed driving schedule may be performed at test points, provided... the proper speed-time relationship, or to permit sampling system adjustments. (e) The drive wheel...
Optimisation of the zinc sulphate turbidity test for the determination of immune status.
Hogan, I; Doherty, M; Fagan, J; Kennedy, E; Conneely, M; Crowe, B; Lorenz, I
2016-02-13
Failure of passive transfer of maternal immunity occurs in calves that fail to absorb sufficient immunoglobulins from ingested colostrum. The zinc sulphate turbidity test has been developed to test bovine neonates for this failure. The specificity of this test has been shown to be less than ideal. The objective was to examine how parameters of the zinc sulphate turbidity test may be manipulated in order to improve its diagnostic accuracy. One hundred and five blood samples were taken from calves of dairy cows receiving various rates of colostrum feeding. The zinc sulphate turbidity test was carried out multiple times on each sample, varying the solution strength, time of reaction and wavelength of light used and the results compared with those of a radial immunodiffusion test, which is the reference method for measuring immunoglobulin concentration in serum. Reducing the time over which the reaction occurs, or increasing the wavelength of light used to read the turbidity, resulted in decreased specificity without improving sensitivity. Increasing the concentration of the zinc sulphate solution used in the test was shown to improve the specificity without decreasing sensitivity. Examination of the cut-off points suggested that a lower cut-off point would improve the performance. British Veterinary Association.
Puelacher, Christian; Wagener, Max; Abächerli, Roger; Honegger, Ursina; Lhasam, Nundsin; Schaerli, Nicolas; Prêtre, Gil; Strebel, Ivo; Twerenbold, Raphael; Boeddinghaus, Jasper; Nestelberger, Thomas; Rubini Giménez, Maria; Hillinger, Petra; Wildi, Karin; Sabti, Zaid; Badertscher, Patrick; Cupa, Janosch; Kozhuharov, Nikola; du Fay de Lavallaz, Jeanne; Freese, Michael; Roux, Isabelle; Lohrmann, Jens; Leber, Remo; Osswald, Stefan; Wild, Damian; Zellweger, Michael J; Mueller, Christian; Reichlin, Tobias
2017-07-01
Exercise ECG stress testing is the most widely available method for evaluation of patients with suspected myocardial ischemia. Its major limitation is the relatively poor accuracy of ST-segment changes regarding ischemia detection. Little is known about the optimal method to assess ST-deviations. A total of 1558 consecutive patients undergoing bicycle exercise stress myocardial perfusion imaging (MPI) were enrolled. Presence of inducible myocardial ischemia was adjudicated using MPI results. The diagnostic value of ST-deviations for detection of exercise-induced myocardial ischemia was systematically analyzed 1) for each individual lead, 2) at three different intervals after the J-point (J+40ms, J+60ms, J+80ms), and 3) at different time points during the test (baseline, maximal workload, 2min into recovery). Exercise-induced ischemia was detected in 481 (31%) patients. The diagnostic accuracy of ST-deviations was highest at +80ms after the J-point, and at 2min into recovery. At this point, ST-amplitude showed an AUC of 0.63 (95% CI 0.59-0.66) for the best-performing lead I. The combination of ST-amplitude and ST-slope in lead I did not increase the AUC. Lead I reached a sensitivity of 37% and a specificity of 83%, with similar sensitivity to manual ECG analysis (34%, p=0.31) but lower specificity (90%, p<0.001). When using ECG stress testing for evaluation of patients with suspected myocardial ischemia, the diagnostic accuracy of ST-deviations is highest when evaluated at +80ms after the J-point, and at 2min into recovery. Copyright © 2017 Elsevier B.V. All rights reserved.
Some analysis on the diurnal variation of rainfall over the Atlantic Ocean
NASA Technical Reports Server (NTRS)
Gill, T.; Perng, S.; Hughes, A.
1981-01-01
Data collected from the GARP Atlantic Tropical Experiment (GATE) was examined. The data were collected from 10,000 grid points arranged as a 100 x 100 array; each grid covered a 4 square km area. The amount of rainfall was measured every 15 minutes during the experiment periods using c-band radars. Two types of analyses were performed on the data: analysis of diurnal variation was done on each of grid points based on the rainfall averages at noon and at midnight, and time series analysis on selected grid points based on the hourly averages of rainfall. Since there are no known distribution model which best describes the rainfall amount, nonparametric methods were used to examine the diurnal variation. Kolmogorov-Smirnov test was used to test if the rainfalls at noon and at midnight have the same statistical distribution. Wilcoxon signed-rank test was used to test if the noon rainfall is heavier than, equal to, or lighter than the midnight rainfall. These tests were done on each of the 10,000 grid points at which the data are available.
Performance testing of 3D point cloud software
NASA Astrophysics Data System (ADS)
Varela-González, M.; González-Jorge, H.; Riveiro, B.; Arias, P.
2013-10-01
LiDAR systems are being used widely in recent years for many applications in the engineering field: civil engineering, cultural heritage, mining, industry and environmental engineering. One of the most important limitations of this technology is the large computational requirements involved in data processing, especially for large mobile LiDAR datasets. Several software solutions for data managing are available in the market, including open source suites, however, users often unknown methodologies to verify their performance properly. In this work a methodology for LiDAR software performance testing is presented and four different suites are studied: QT Modeler, VR Mesh, AutoCAD 3D Civil and the Point Cloud Library running in software developed at the University of Vigo (SITEGI). The software based on the Point Cloud Library shows better results in the loading time of the point clouds and CPU usage. However, it is not as strong as commercial suites in working set and commit size tests.
Liu, Guang-Mao; Jin, Dong-Hai; Jiang, Xi-Hang; Zhou, Jian-Ye; Zhang, Yan; Chen, Hai-Bo; Hu, Sheng-Shou; Gui, Xing-Min
The ventricular assist pumps do not always function at the design point; instead, these pumps may operate at unfavorable off-design points. For example, the axial ventricular assist pump FW-2, in which the design point is 5 L/min flow rate against 100 mm Hg pressure increase at 8,000 rpm, sometimes works at off-design flow rates of 1 to 4 L/min. The hemolytic performance of the FW-2 at both the design point and at off-design points was estimated numerically and tested in vitro. Flow characteristics in the pump were numerically simulated and analyzed with special attention paid to the scalar sheer stress and exposure time. An in vitro hemolysis test was conducted to verify the numerical results. The simulation results showed that the scalar shear stress in the rotor region at the 1 L/min off-design point was 70% greater than at the 5 L/min design point. The hemolysis index at the 1 L/min off-design point was 3.6 times greater than at the 5 L/min design point. The in vitro results showed that the normalized index of hemolysis increased from 0.017 g/100 L at the 5 L/min design point to 0.162 g/100 L at the 1 L/min off-design point. The hemolysis comparison between the different blood pump flow rates will be helpful for future pump design point selection and will guide the usage of ventricular assist pumps. The hemolytic performance of the blood pump at the working point in the clinic should receive more focus.
International definition of a point-of-care test in family practice: a modified e-Delphi procedure.
Schols, Angel M R; Dinant, Geert-Jan; Hopstaken, Rogier; Price, Christopher P; Kusters, Ron; Cals, Jochen W L
2018-01-29
The use of point-of-care tests (POCTs) in family practice is increasing, and the term POCT is often used in medical literature and clinical practice. Yet, no widely supported definition by several professional fields exists. To reach consensus on an international definition of a POCT in family practice. We performed a modified international e-Delphi procedure of four rounds among expert panel members from different professional backgrounds-family practitioners, laboratory specialists, policymakers, researchers and manufacturers. Of 27 panel members from seven different countries, 26 participated in all rounds. Most panel members were active in POCT research or policymaking and 70% worked in family medicine. After choosing important components, structuring of answers and feedback, the following definition was chosen as the best or second best definition by 81% of panel members: a point-of-care test in family practice is a test to support clinical decision making, which is performed by a qualified member of the practice staff nearby the patient and on any part of the patient's body or its derivatives, during or very close to the time of consultation, to help the patient and physician to decide upon the best suited approach, and of which the results should be known at the time of the clinical decision making. The definition emerging from this study can inform family practitioners, laboratory specialists, policymakers and manufacturers on the most widely supported and recognized definition and could act as a clear starting point for the organization and execution of professional point-of-care testing in family practice worldwide. © The Author(s) 2018. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Zhou, Jian-Li; Xing, Jun; Liu, Cong-Hui; Wen, Jie; Zhao, Nan-Nan; Kang, Yuan-Yuan; Shao, Ting
2018-05-01
With the improvement of living standard, gestational diabetes mellitus (GDM) incidence is increasing every year. We observed the effects of abnormal 75 g oral glucose tolerance test (OGTT) at different time points on neonatal complications and neurobehavioral development in GDM.A total of 144 newborns whose mothers were diagnosed with GDM and received prenatal examination and childbirth in our hospital from October 2015 to April 2016, were observed in this study. Pregnant women underwent 75 g OGTT and the blood glucose level was recorded on an empty stomach, as well as postprandial 1 and 2 hours, respectively. Based on the frequency of 75 g OGTT-abnormal time points, the pregnant women were divided into group 1 (OGTT abnormality at 1 time point), group 2 (OGTT abnormality at 2 time points), and group 3 (OGTT abnormality at 3 time points). Neonatal behavioral neurological assessment (NBNA) was performed on the 3 groups, respectively.In the total score of NBNA, there was a significant difference among the 3 groups (F = 17.120, P = .000), and there were significant differences between the 3 groups (all P < .05). The incidence of neonatal hypoglycemia was significantly lower in groups 1 and 2 than in group 3, and the incidence of macrosomia was significantly lower in groups 1 than in groups 2 and 3 (all P < .05). In the 144 newborns, NBNA scoring was significantly lower in the newborns with hypoglycemia than in the newborns with normal blood glucose level, and in macrosomia than in the newborns with normal body weight (all P < .01).With the increase of OGTT-abnormal time points in the pregnant women with GDM, the incidences of neonatal hypoglycemia and macrosomia rise and neonatal NBNA score decreases. Therefore, reasonable measures should be adopted as early as possible to prevent poor prognosis in the pregnant women with GDM.
ERIC Educational Resources Information Center
Gu, Lin; Lockwood, John; Powers, Donald E.
2015-01-01
Standardized tests are often designed to provide only a snapshot of test takers' knowledge, skills, or abilities at a single point in time. Sometimes, however, they are expected to serve more demanding functions, one of them is assessing change in knowledge, skills, or ability over time because of learning effects.The latter is the case for the…
Statistical aspects of point count sampling
Barker, R.J.; Sauer, J.R.; Ralph, C.J.; Sauer, J.R.; Droege, S.
1995-01-01
The dominant feature of point counts is that they do not census birds, but instead provide incomplete counts of individuals present within a survey plot. Considering a simple model for point count sampling, we demon-strate that use of these incomplete counts can bias estimators and testing procedures, leading to inappropriate conclusions. A large portion of the variability in point counts is caused by the incomplete counting, and this within-count variation can be confounded with ecologically meaningful varia-tion. We recommend caution in the analysis of estimates obtained from point counts. Using; our model, we also consider optimal allocation of sampling effort. The critical step in the optimization process is in determining the goals of the study and methods that will be used to meet these goals. By explicitly defining the constraints on sampling and by estimating the relationship between precision and bias of estimators and time spent counting, we can predict the optimal time at a point for each of several monitoring goals. In general, time spent at a point will differ depending on the goals of the study.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eslinger, Paul W.; Bowyer, Ted W.; Cameron, Ian M.
2015-10-01
The International Monitoring System contains up to 80 stations around the world that have aerosol and xenon monitoring systems designed to detect releases of radioactive materials to the atmosphere from nuclear tests. A rule of thumb description of plume concentration and duration versus time and distance from the release point is useful when designing and deploying new sample collection systems. This paper uses plume development from atmospheric transport modeling to provide a power-law rule describing atmospheric dilution factors as a function of distance from the release point.
Negatively valenced expectancy violation predicts emotionality: A longitudinal analysis.
Bettencourt, B Ann; Manning, Mark
2016-09-01
We hypothesized that negatively valenced expectancy violations about the quality of 1's life would predict negative emotionality. We tested this hypothesis in a 4-wave longitudinal study of breast cancer survivors. The findings showed that higher levels of negatively valenced expectancy violation, at earlier time points, were associated with greater negative emotionality, at later time points. Implications of the findings are discussed. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Building a LiDAR point cloud simulator: Testing algorithms for high resolution topographic change
NASA Astrophysics Data System (ADS)
Carrea, Dario; Abellán, Antonio; Derron, Marc-Henri; Jaboyedoff, Michel
2014-05-01
Terrestrial laser technique (TLS) is becoming a common tool in Geosciences, with clear applications ranging from the generation of a high resolution 3D models to the monitoring of unstable slopes and the quantification of morphological changes. Nevertheless, like every measurement techniques, TLS still has some limitations that are not clearly understood and affect the accuracy of the dataset (point cloud). A challenge in LiDAR research is to understand the influence of instrumental parameters on measurement errors during LiDAR acquisition. Indeed, different critical parameters interact with the scans quality at different ranges: the existence of shadow areas, the spatial resolution (point density), and the diameter of the laser beam, the incidence angle and the single point accuracy. The objective of this study is to test the main limitations of different algorithms usually applied on point cloud data treatment, from alignment to monitoring. To this end, we built in MATLAB(c) environment a LiDAR point cloud simulator able to recreate the multiple sources of errors related to instrumental settings that we normally observe in real datasets. In a first step we characterized the error from single laser pulse by modelling the influence of range and incidence angle on single point data accuracy. In a second step, we simulated the scanning part of the system in order to analyze the shifting and angular error effects. Other parameters have been added to the point cloud simulator, such as point spacing, acquisition window, etc., in order to create point clouds of simple and/or complex geometries. We tested the influence of point density and vitiating point of view on the Iterative Closest Point (ICP) alignment and also in some deformation tracking algorithm with same point cloud geometry, in order to determine alignment and deformation detection threshold. We also generated a series of high resolution point clouds in order to model small changes on different environments (erosion, landslide monitoring, etc) and we then tested the use of filtering techniques using 3D moving windows along the space and time, which considerably reduces data scattering due to the benefits of data redundancy. In conclusion, the simulator allowed us to improve our different algorithms and to understand how instrumental error affects final results. And also, improve the methodology of scans acquisition to find the best compromise between point density, positioning and acquisition time with the best accuracy possible to characterize the topographic change.
NASA Astrophysics Data System (ADS)
Zhu, Yuxiang; Jiang, Jianmin; Huang, Changxing; Chen, Yongqin David; Zhang, Qiang
2018-04-01
This article, as part I, introduces three algorithms and applies them to both series of the monthly stream flow and rainfall in Xijiang River, southern China. The three algorithms include (1) normalization of probability distribution, (2) scanning U test for change points in correlation between two time series, and (3) scanning F-test for change points in variances. The normalization algorithm adopts the quantile method to normalize data from a non-normal into the normal probability distribution. The scanning U test and F-test have three common features: grafting the classical statistics onto the wavelet algorithm, adding corrections for independence into each statistic criteria at given confidence respectively, and being almost objective and automatic detection on multiscale time scales. In addition, the coherency analyses between two series are also carried out for changes in variance. The application results show that the changes of the monthly discharge are still controlled by natural precipitation variations in Xijiang's fluvial system. Human activities disturbed the ecological balance perhaps in certain content and in shorter spells but did not violate the natural relationships of correlation and variance changes so far.
Estimating Statistical Power When Making Adjustments for Multiple Tests
ERIC Educational Resources Information Center
Porter, Kristin E.
2016-01-01
In recent years, there has been increasing focus on the issue of multiple hypotheses testing in education evaluation studies. In these studies, researchers are typically interested in testing the effectiveness of an intervention on multiple outcomes, for multiple subgroups, at multiple points in time or across multiple treatment groups. When…
Performance Evaluation of Real-Time Precise Point Positioning Method
NASA Astrophysics Data System (ADS)
Alcay, Salih; Turgut, Muzeyyen
2017-12-01
Post-Processed Precise Point Positioning (PPP) is a well-known zero-difference positioning method which provides accurate and precise results. After the experimental tests, IGS Real Time Service (RTS) officially provided real time orbit and clock products for the GNSS community that allows real-time (RT) PPP applications. Different software packages can be used for RT-PPP. In this study, in order to evaluate the performance of RT-PPP, 3 IGS stations are used. Results, obtained by using BKG Ntrip Client (BNC) Software v2.12, are examined in terms of both accuracy and precision.
Alles, Susan; Peng, Linda X; Mozola, Mark A
2009-01-01
A modification to Performance-Tested Method (PTM) 070601, Reveal Listeria Test (Reveal), is described. The modified method uses a new media formulation, LESS enrichment broth, in single-step enrichment protocols for both foods and environmental sponge and swab samples. Food samples are enriched for 27-30 h at 30 degrees C and environmental samples for 24-48 h at 30 degrees C. Implementation of these abbreviated enrichment procedures allows test results to be obtained on a next-day basis. In testing of 14 food types in internal comparative studies with inoculated samples, there was a statistically significant difference in performance between the Reveal and reference culture [U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA/BAM) or U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS)] methods for only a single food in one trial (pasteurized crab meat) at the 27 h enrichment time point, with more positive results obtained with the FDA/BAM reference method. No foods showed statistically significant differences in method performance at the 30 h time point. Independent laboratory testing of 3 foods again produced a statistically significant difference in results for crab meat at the 27 h time point; otherwise results of the Reveal and reference methods were statistically equivalent. Overall, considering both internal and independent laboratory trials, sensitivity of the Reveal method relative to the reference culture procedures in testing of foods was 85.9% at 27 h and 97.1% at 30 h. Results from 5 environmental surfaces inoculated with various strains of Listeria spp. showed that the Reveal method was more productive than the reference USDA-FSIS culture procedure for 3 surfaces (stainless steel, plastic, and cast iron), whereas results were statistically equivalent to the reference method for the other 2 surfaces (ceramic tile and sealed concrete). An independent laboratory trial with ceramic tile inoculated with L. monocytogenes confirmed the effectiveness of the Reveal method at the 24 h time point. Overall, sensitivity of the Reveal method at 24 h relative to that of the USDA-FSIS method was 153%. The Reveal method exhibited extremely high specificity, with only a single false-positive result in all trials combined for overall specificity of 99.5%.
Aligning Scales of Certification Tests. Research Report. ETS RR-10-07
ERIC Educational Resources Information Center
Dorans, Neil J.; Liang, Longjuan; Puhan, Gautam
2010-01-01
Scores are the most visible and widely used products of a testing program. The choice of score scale has implications for test specifications, equating, and test reliability and validity, as well as for test interpretation. At the same time, the score scale should be viewed as infrastructure likely to require repair at some point. In this report…
Smoke-Point Properties of Non-Buoyant Round Laminar Jet Diffusion Flames. Appendix J
NASA Technical Reports Server (NTRS)
Urban, D. L.; Yuan, Z.-G.; Sunderland, P. B.; Lin, K.-C.; Dai, Z.; Faeth, G. M.
2000-01-01
The laminar smoke-point properties of non-buoyant round laminar jet diffusion flames were studied emphasizing results from long-duration (100-230 s) experiments at microgravity carried out in orbit aboard the space shuttle Columbia. Experimental conditions included ethylene- and propane-fueled flames burning in still air at an ambient temperature of 300 K, pressures of 35-130 kPa, jet exit diameters of 1.6 and 2.7 mm, jet exit velocities of 170-690 mm/s, jet exit Reynolds numbers of 46-172, characteristic flame residence times of 40-302 ms, and luminous flame lengths of 15-63 mm. Contrary to the normal-gravity laminar smoke point, in microgravity, the onset of laminar smoke-point conditions involved two flame configurations: closed-tip flames with soot emissions along the flame axis and open-tip flames with soot emissions from an annular ring about the flame axis. Open-tip flames were observed at large characteristic flame residence times with the onset of soot emissions associated with radiative quenching near the flame tip: nevertheless, unified correlations of laminar smoke-point properties were obtained that included both flame configurations. Flame lengths at laminar smoke-point conditions were well correlated in terms of a corrected fuel flow rate suggested by a simplified analysis of flame shape. The present steady and non-buoyant flames emitted soot more readily than non-buoyant flames in earlier tests using ground-based microgravity facilities and than buoyant flames at normal gravity, as a result of reduced effects of unsteadiness, flame disturbances, and buoyant motion. For example, present measurements of laminar smoke-point flame lengths at comparable conditions were up to 2.3 times shorter than ground-based microgravity measurements and up to 6.4 times shorter than buoyant flame measurements. Finally, present laminar smoke-point flame lengths were roughly inversely proportional to pressure to a degree that is a somewhat smaller than observed during earlier tests both at microgravity (using ground-based facilities) and at normal gravity.
Özyol, Pelin; Özyol, Erhan; Karalezli, Aylin
2018-01-01
To examine the effect of a single dose of artificial tear administration on automated visual field (VF) testing in patients with glaucoma and dry eye syndrome. A total of 35 patients with primary open-angle glaucoma experienced in VF testing with symptoms of dry eye were enrolled in this study. At the first visit, standard VF testing was performed. At the second and third visits with an interval of one week, while the left eyes served as control, one drop of artificial tear was administered to each patient's right eye, and then VF testing was performed again. The reliability parameters, VF indices, number of depressed points at probability levels of pattern deviation plots, and test times were compared between visits. No significant difference was observed in any VF testing parameters of control eyes (P>0.05). In artificial tear administered eyes, significant improvement was observed in test duration, mean deviation, and the number of depressed points at probability levels (P˂0.5%, P˂1%, P˂2) of pattern deviation plots (P˂0.05). The post-hoc test revealed that artificial tear administration elicited an improvement in test duration, mean deviation, and the number of depressed points at probability levels (P˂0.5%, P˂1%, P˂2%) of pattern deviation plots from first visit to second and third visits (P˂0.01, for all comparisons). The intraclass correlation coefficient for the three VF test indices was found to be between 0.735 and 0.85 (P<0.001, for all). A single dose of artificial tear administration immediately before VF testing seems to improve test results and decrease test time.
Impact of point-of-care implementation of Xpert® MTB/RIF: product vs. process innovation.
Schumacher, S G; Thangakunam, B; Denkinger, C M; Oliver, A A; Shakti, K B; Qin, Z Z; Michael, J S; Luo, R; Pai, M; Christopher, D J
2015-09-01
Both product innovation (e.g., more sensitive tests) and process innovation (e.g., a point-of-care [POC] testing programme) could improve patient outcomes. To study the respective contributions of product and process innovation in improving patient outcomes. We implemented a POC programme using Xpert(®) MTB/RIF in an out-patient clinic of a tertiary care hospital in India. We measured the impact of process innovation by comparing time to diagnosis with routine testing vs. POC testing. We measured the impact of product innovation by comparing accuracy and time to diagnosis using smear microscopy vs. POC Xpert. We enrolled 1012 patients over a 15-month period. Xpert had high accuracy, but the incremental value of one Xpert over two smears was only 6% (95%CI 3-12). Implementing Xpert as a routine laboratory test did not reduce the time to diagnosis compared to smear-based diagnosis. In contrast, the POC programme reduced the time to diagnosis by 5.5 days (95%CI 4.3-6.7), but required dedicated staff and substantial adaptation of clinic workflow. Process innovation by way of a POC Xpert programme had a greater impact on time to diagnosis than the product per se, and can yield important improvements in patient care that are complementary to those achieved by introducing innovative technologies.
Craig, Darren G; Kitto, Laura; Zafar, Sara; Reid, Thomas W D J; Martin, Kirsty G; Davidson, Janice S; Hayes, Peter C; Simpson, Kenneth J
2014-09-01
The innate immune system is profoundly dysregulated in paracetamol (acetaminophen)-induced liver injury. The neutrophil-lymphocyte ratio (NLR) is a simple bedside index with prognostic value in a number of inflammatory conditions. To evaluate the prognostic accuracy of the NLR in patients with significant liver injury following single time-point and staggered paracetamol overdoses. Time-course analysis of 100 single time-point and 50 staggered paracetamol overdoses admitted to a tertiary liver centre. Timed laboratory samples were correlated with time elapsed after overdose or admission, respectively, and the NLR was calculated. A total of 49/100 single time-point patients developed hepatic encephalopathy (HE). Median NLRs were higher at both 72 (P=0.0047) and 96 h after overdose (P=0.0041) in single time-point patients who died or were transplanted. Maximum NLR values by 96 h were associated with increasing HE grade (P=0.0005). An NLR of more than 16.7 during the first 96 h following overdose was independently associated with the development of HE [odds ratio 5.65 (95% confidence interval 1.67-19.13), P=0.005]. Maximum NLR values by 96 h were strongly associated with the requirement for intracranial pressure monitoring (P<0.0001), renal replacement therapy (P=0.0002) and inotropic support (P=0.0005). In contrast, in the staggered overdose cohort, the NLR was not associated with adverse outcomes or death/transplantation either at admission or subsequently. The NLR is a simple test which is strongly associated with adverse outcomes following single time-point, but not staggered, paracetamol overdoses. Future studies should assess the value of incorporating the NLR into existing prognostic and triage indices of single time-point paracetamol overdose.
Study of Laser Reflectivity on Skin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oidor-Garcia, J. J. J.; Trevino-Palacios, C. G.
2008-08-11
The response to the light on the skin can be manifested as temperature increase or creation of biochemical byproducts, in which further studies are required to asset the light effect. This response changes the average response over time and can produce discrepancies between similar studies. In this work we present a Low Level Laser Therapy (LLLT) study with feedback. We study the time response reflectivity of a 980 nm laser diode of 25 mW modulated at frequencies close to 40 kHz and detect the reflected light on a silicon photodiode, finding no direct correlation between different test points or individuals,more » while finding reproducible responses within the same individual and test point.« less
Live Aircraft Encounter Visualization at FutureFlight Central
NASA Technical Reports Server (NTRS)
Murphy, James R.; Chinn, Fay; Monheim, Spencer; Otto, Neil; Kato, Kenji; Archdeacon, John
2018-01-01
Researchers at the National Aeronautics and Space Administration (NASA) have developed an aircraft data streaming capability that can be used to visualize live aircraft in near real-time. During a joint Federal Aviation Administration (FAA)/NASA Airborne Collision Avoidance System flight series, test sorties between unmanned aircraft and manned intruder aircraft were shown in real-time at NASA Ames' FutureFlight Central tower facility as a virtual representation of the encounter. This capability leveraged existing live surveillance, video, and audio data streams distributed through a Live, Virtual, Constructive test environment, then depicted the encounter from the point of view of any aircraft in the system showing the proximity of the other aircraft. For the demonstration, position report data were sent to the ground from on-board sensors on the unmanned aircraft. The point of view can be change dynamically, allowing encounters from all angles to be observed. Visualizing the encounters in real-time provides a safe and effective method for observation of live flight testing and a strong alternative to travel to the remote test range.
Standard Samples and Reference Standards Issued by the National Bureau of Standards
1954-08-31
precision and accuracy of control testing in the melting - point , density, index of refraction, heat rubber industry. of combustion, color, and gloss...pH (approx.) 1.7 65 2.50 Melting - Point Standards 44d Aluminum ---------------------------- 659.70 C...calculating the best frequencies for communication between any two points in the world at any time during the given month. The data are important to all
Field test of wavelength-saving quantum key distribution network.
Wang, Shuang; Chen, Wei; Yin, Zhen-Qiang; Zhang, Yang; Zhang, Tao; Li, Hong-Wei; Xu, Fang-Xing; Zhou, Zheng; Yang, Yang; Huang, Da-Jun; Zhang, Li-Jun; Li, Fang-Yi; Liu, Dong; Wang, Yong-Gang; Guo, Guang-Can; Han, Zheng-Fu
2010-07-15
We propose a wavelength-saving topology of a quantum key distribution (QKD) network based on passive optical elements, and we report on the field test of this network on commercial telecom optical fiber at the frequency of 20 MHz. In this network, five nodes are supported with two wavelengths, and every two nodes can share secure keys directly at the same time. We also characterized the insertion loss and cross talk effects on the point-to-point QKD system after introducing this QKD network.
Atmospheric Characterization During Super-Resolution Vision System Developmental Testing
2013-05-01
local time each day of the test. RM Young 81000 sonic anemometers were located at 0-, 800-, and 1800-m target points at 1.5-m elevation to provide point...estimates of C2n. Sonic anemometer data were also collected at a 0-km tower at several levels, providing a vertical turbulence profile. Turbulence...Atmospheric Instrumentation and Analysis 8 4. Estimation of C2n from Sonic Anemometer Data 11 5. Data Plots 14 6. Derived Results 32 7. Conclusions 36 8
DOE Office of Scientific and Technical Information (OSTI.GOV)
Henager, Charles H.
PNNL has performed mechanical property tests on two types of Hi-Nicalon Type-S fiber SiC/SiC composites for the general purpose of evaluating such composites for control rod guide tube applications in the NGNP high-temperature gas-cooled reactor design. The mechanical testing consisted of 4-point bend strength, 4-point single-edge notched bend fracture toughness, and 4-point bend slow crack growth testing on both composites from ambient to 1600°C (1873K). The two composite materials that were tested included a ±55°-braided-weave composite with Type-S fibers inclined at 55° to the principal composite axes to simulate a braided tube architecture and a Type-S 0/90 satin-weave composite asmore » a reference material.« less
Mauk, Michael G.; Song, Jinzhao; Liu, Changchun; Bau, Haim H.
2018-01-01
Designs and applications of microfluidics-based devices for molecular diagnostics (Nucleic Acid Amplification Tests, NAATs) in infectious disease testing are reviewed, with emphasis on minimally instrumented, point-of-care (POC) tests for resource-limited settings. Microfluidic cartridges (‘chips’) that combine solid-phase nucleic acid extraction; isothermal enzymatic nucleic acid amplification; pre-stored, paraffin-encapsulated lyophilized reagents; and real-time or endpoint optical detection are described. These chips can be used with a companion module for separating plasma from blood through a combined sedimentation-filtration effect. Three reporter types: Fluorescence, colorimetric dyes, and bioluminescence; and a new paradigm for end-point detection based on a diffusion-reaction column are compared. Multiplexing (parallel amplification and detection of multiple targets) is demonstrated. Low-cost detection and added functionality (data analysis, control, communication) can be realized using a cellphone platform with the chip. Some related and similar-purposed approaches by others are surveyed. PMID:29495424
Postural Balance Following Aerobic Fatigue Tests: A Longitudinal Study Among Young Athletes.
Steinberg, Nili; Eliakim, Alon; Zaav, Aviva; Pantanowitz, Michal; Halumi, Monder; Eisenstein, Tamir; Meckel, Yoav; Nemet, Dan
2016-01-01
General fatigue can cause aggravation of postural balance, with increased risk for injuries. The present longitudinal study aimed to evaluate the postural balance of young athletes following field aerobic tests throughout 1 year of training. Thirty children from a sports center in Nazareth, participating in a 3 times/week training program (specific to basketball, soccer, or athletic training), were assessed. Postural balance parameters were taken before, immediately after, and 10 min after a 20 m shuttle-run aerobic test, at 3 time points during 1 training year (Start/Y, Mid/Y, and End/Y). Fitness improved at the Mid/Y and End/Y compared to Start/Y. Postural balance significantly deteriorated immediately after the aerobic test and improved significantly in the 10-min testing in all 3 time points, with significant deterioration in the End/Y compared with the Start/Y. In conclusions, postural balance deteriorates immediately after aerobic exercises, and at the end of the year. To better practice drills related to postural balance and possibly to prevent injuries, it is best for young athletes to properly rest immediately following aerobic exercises and to practice postural balance mainly at the beginning and at the middle of the training year.
Johnson, Jeffrey P.; Villard, Sarah; Kiran, Swathi
2017-01-01
Purpose This study was conducted to investigate the static and dynamic relationships between impairment-level cognitive-linguistic abilities and activity-level functional communication skills in persons with aphasia (PWA). Method In Experiment 1, a battery of standardized assessments was administered to a group of PWA (N = 72) to examine associations between cognitive-linguistic ability and functional communication at a single time point. In Experiment 2, impairment-based treatment was administered to a subset of PWA from Experiment 1 (n = 39) in order to examine associations between change in cognitive-linguistic ability and change in function and associations at a single time point. Results In both experiments, numerous significant associations were found between scores on tests of cognitive-linguistic ability and a test of functional communication at a single time point. In Experiment 2, significant treatment-induced gains were seen on both types of measures in participants with more severe aphasia, yet cognitive-linguistic change scores were not significantly correlated with functional communication change scores. Conclusions At a single time point, cognitive-linguistic and functional communication abilities are associated in PWA. However, although changes on standardized assessments reflecting improvements in both types of skills can occur following an impairment-based therapy, these changes may not be significantly associated with each other. PMID:28196373
Comparing Behavior Modification Approaches to Habit Decrement--Smoking
ERIC Educational Resources Information Center
Wagner, M. K.; Bragg, R. A.
1970-01-01
Five methods for control of smoking were tested on 54 Ss using systematic desensitization (SD), covert sensitization (CS), a combination of SD and CS (SD-CS), relaxation, and counseling. The SD-CS treatment was superior at all points during the treatment, though not significantly superior to all other treatments at all time points. Reprints from…
This paper presents a technique for determining the trace gas emission rate from a point source. The technique was tested using data from controlled methane release experiments and from measurement downwind of a natural gas production facility in Wyoming. Concentration measuremen...
Standard of Practice and Flynn Effect Testimony in Death Penalty Cases
ERIC Educational Resources Information Center
Gresham, Frank M.; Reschly, Daniel J.
2011-01-01
The Flynn Effect is a well-established psychometric fact documenting substantial increases in measured intelligence test performance over time. Flynn's (1984) review of the literature established that Americans gain approximately 0.3 points per year or 3 points per decade in measured intelligence. The accurate assessment and interpretation of…
NASA Astrophysics Data System (ADS)
Wüst, Sabine; Wendt, Verena; Linz, Ricarda; Bittner, Michael
2017-09-01
Cubic splines with equidistant spline sampling points are a common method in atmospheric science, used for the approximation of background conditions by means of filtering superimposed fluctuations from a data series. What is defined as background or superimposed fluctuation depends on the specific research question. The latter also determines whether the spline or the residuals - the subtraction of the spline from the original time series - are further analysed.Based on test data sets, we show that the quality of approximation of the background state does not increase continuously with an increasing number of spline sampling points and/or decreasing distance between two spline sampling points. Splines can generate considerable artificial oscillations in the background and the residuals.We introduce a repeating spline approach which is able to significantly reduce this phenomenon. We apply it not only to the test data but also to TIMED-SABER temperature data and choose the distance between two spline sampling points in a way that is sensitive for a large spectrum of gravity waves.
Corn, Carolyn E; Klepser, Donald G; Dering-Anderson, Allison M; Brown, Terrence G; Klepser, Michael E; Smith, Jaclyn K
2018-06-01
Acute pharyngitis is among the most common infectious diseases encountered in the United States, resulting in 13 million patient visits annually, with group A streptococcus (GAS) being a common causative pathogen. It is estimated that annual expenditures for the treatment of adult pharyngitis will exceed US$1.2 billion annually. This substantial projection reinforces the need to evaluate diagnosis and treatment of adult pharyngitis in nontraditional settings. The objective of this research is to quantify the amount of pharmacist time required to complete a point-of-care (POC) test for a patient presenting with pharyngitis symptoms. A standardized patient with pharyngitis symptoms visited 11 pharmacies for POC testing services for a total of 33 patient encounters. An observer was present at each encounter and recorded the total encounter time, divided into 9 categories. Pharmacists conducted POC testing in 1 of 2 ways: sequence 1-pharmacists performed all service-related tasks; sequence 2-both pharmacists and pharmacist interns performed service-related tasks. The average time for completion of a POC test for GAS pharyngitis was 25.3 ± 4.8 minutes. The average pharmacist participation time per encounter was 12.7 ± 3.0 minutes (sequence 1), which decreased to 2.6 ± 1.1 minutes when pharmacist interns were involved in the testing (sequence 2). Although additional studies are required to further assess service feasibility, this study indicates that a GAS POC testing service could be implemented in a community pharmacy with limited disruption or change to workflow and staff.
Standardized Tests: Purpose Is the Point
ERIC Educational Resources Information Center
Popham, W. James
2016-01-01
"U.S. students are being educated less well these days than they should be," writes W. James Popham. One key contributing factor is that educators often use the wrong tests to make their most important educational decisions. Two recent events have made it a perfect time to change the way we conduct our educational testing: growing…
ERIC Educational Resources Information Center
Porter, Kristin E.
2018-01-01
Researchers are often interested in testing the effectiveness of an intervention on multiple outcomes, for multiple subgroups, at multiple points in time, or across multiple treatment groups. The resulting multiplicity of statistical hypothesis tests can lead to spurious findings of effects. Multiple testing procedures (MTPs) are statistical…
Liporace, Frank A; Breitbart, Eric A; Yoon, Richard S; Doyle, Erin; Paglia, David N; Lin, Sheldon
2015-06-01
Recombinant human bone morphogenetic protein-2 (rhBMP-2) is particularly effective in improving osteogenesis in patients with diminished bone healing capabilities, such as individuals with type 1 diabetes mellitus (T1DM) who have impaired bone healing capabilities and increased risk of developing osteoporosis. This study measured the effects of rhBMP-2 treatment on osteogenesis by observing the dose-dependent effect of localized delivery of rhBMP-2 on biomechanical parameters of bone using a hydroxyapatite/tri-calcium phosphate (HA/TCP) carrier in a T1DM-related osteoporosis animal model. Two different doses of rhBMP-2 (LD low dose, HD high dose) with a HA/TCP carrier were injected into the femoral intramedullary canal of rats with T1DM-related osteoporosis. Two more diabetic rat groups were injected with saline alone and with HA/TCP carrier alone. Radiographs and micro-computed tomography were utilized for qualitative assessment of bone mineral density (BMD). Biomechanical testing occurred at 4- and 8-week time points; parameters tested included torque to failure, torsional rigidity, shear stress, and shear modulus. At the 4-week time point, the LD and HD groups both exhibited significantly higher BMD than controls; at the 8-week time point, the HD group exhibited significantly higher BMD than controls. Biomechanical testing revealed dose-dependent, higher trends in all parameters tested at the 4- and 8-week time points, with minimal significant differences. Groups treated with rhBMP-2 demonstrated improved bone mineral density at both 4 and 8 weeks compared to control saline groups, in addition to strong trends towards improvement of intrinsic and extrinsic biomechanical properties when compared to control groups. Data revealed trends toward dose-dependent increases in peak torque, torsional rigidity, shear stress, and shear modulus 4 weeks after rhBMP-2 treatment. Not applicable.
Gulart, Aline Almeida; Munari, Anelise Bauer; Klein, Suelen Roberta; Santos da Silveira, Lucas; Mayer, Anamaria Fleig
2018-02-01
The study objective was to determine a cut-off point for the Glittre activities of daily living (ADL)test (TGlittre) to discriminate patients with normal and abnormal functional capacity. Fifty-nine patients with moderate to very severe COPD (45 males; 65 ± 8.84 years; BMI: 26 ± 4.78 kg/m 2 ; FEV 1 : 35.3 ± 13.4% pred) were evaluated for spirometry, TGlittre, 6-minute walk test (6 MWT), physical ADL, modified Medical Research Council scale (mMRC), BODE index, Saint George's Respiratory Questionnaire (SGRQ), and COPD Assessment Test (CAT). The receiver operating characteristic (ROC) curve was used to determine the cut-off point for TGlittre in order to discriminate patients with 6 MWT < 82% pred. The ROC curve indicated a cut-off point of 3.5 minutes for the TGlittre (sensitivity = 92%, specificity = 83%, and area under the ROC curve = 0.95 [95% CI: 0.89-0.99]). Patients with abnormal functional capacity had higher mMRC (median difference 1 point), CAT (mean difference: 4.5 points), SGRQ (mean difference: 12.1 points), and BODE (1.37 points) scores, longer time of physical activity <1.5 metabolic equivalent of task (mean difference: 47.9 minutes) and in sitting position (mean difference: 59.4 minutes) and smaller number of steps (mean difference: 1,549 minutes); p < 0.05 for all. In conclusion, the cut-off point of 3.5 minutes in the TGlittre is sensitive and specific to distinguish COPD patients with abnormal and normal functional capacity.
Test of cold asphalt storability based on alternative approaches
NASA Astrophysics Data System (ADS)
Abaffyová, Zora; Komačka, Jozef
2017-09-01
Cold asphalt products for potholes repairs should be workable (soft enough) for long time to ensure their applicability. Storability is assessed indirectly using various tests of workability. Therefore, simple test methods (self-compaction and disintegration test) was developed and verified to investigate changes of storability of this group of cold asphalts. Selfcompaction of the tested mixture in the upturned Abram’s cone for the cement concrete slump test and in the mould for the California Bearing Ratio test was assessed in first stage. After that the video record of disintegration test was taken. During this test, the mould was lifted up and the mixture fell off the mould (Abram’s cone) or disintegrate (CBR mould). The drop of surface after 10 min self-compaction and netto time related to falling out or disintegration of the mixture were used to evaluate the mixture from storability point of view. It was found out the self-compaction test has not a potential to reveal and prove changes of mixture properties. Based on the disintegration test results it can be stated this test at 5 °C using the upturned Abram’s cone could be a suitable approach to determine qualitative changes of a cold mixture from storability point of view.
New and developing diagnostic technologies for urinary tract infections
Davenport, Michael; Mach, Kathleen E.; Dairiki Shortliffe, Linda M.; Banaei, Niaz; Wang, Tza-Huei; Liao, Joseph C.
2017-01-01
Timely and accurate identification and determination of the antimicrobial susceptibility of uropathogens is central to the management of UTIs. Urine dipsticks are fast and amenable to point-of-care testing, but do not have adequate diagnostic accuracy or provide microbiological diagnosis. Urine culture with antimicrobial susceptibility testing takes 2 3 days and requires a clinical laboratory. The common use of empirical antibiotics has contributed to the rise of multidrug-resistant organisms, reducing treatment options and increasing costs. In addition to improved antimicrobial stewardship and the development of new antimicrobials, novel diagnostics are needed for timely microbial identification and determination of antimicrobial susceptibilities. New diagnostic platforms, including nucleic acid tests and mass spectrometry, have been approved for clinical use and have improved the speed and accuracy of pathogen identification from primary cultures. Optimization for direct urine testing would reduce the time to diagnosis, yet these technologies do not provide comprehensive information on antimicrobial susceptibility. Emerging technologies including biosensors, microfluidics, and other integrated platforms could improve UTI diagnosis via direct pathogen detection from urine samples, rapid antimicrobial susceptibility testing, and point-of-care testing. Successful development and implementation of these technologies has the potential to usher in an era of precision medicine to improve patient care and public health. PMID:28248946
Silveira, Hevely Saray Lima; Simões-Zenari, Marcia; Kulcsar, Marco Aurélio; Cernea, Claudio Roberto; Nemr, Kátia
2017-10-27
The supracricoid partial laryngectomy allows the preservation of laryngeal functions with good local cancer control. To assess laryngeal configuration and voice analysis data following the performance of a combination of two vocal exercises: the prolonged /b/vocal exercise combined with the vowel /e/ using chest and arm pushing with different durations among individuals who have undergone supracricoid laryngectomy. Eleven patients undergoing partial laryngectomy supracricoid with cricohyoidoepiglottopexy (CHEP) were evaluated using voice recording. Four judges performed separately a perceptive-vocal analysis of hearing voices, with random samples. For the analysis of intrajudge reliability, repetitions of 70% of the voices were done. Intraclass correlation coefficient was used to analyze the reliability of the judges. For an analysis of each judge to the comparison between zero time (time point 0), after the first series of exercises (time point 1), after the second series (time point 2), after the third series (time point 3), after the fourth series (time point 4), and after the fifth and final series (time point 5), the Friedman test was used with a significance level of 5%. The data relative to the configuration of the larynx were subjected to a descriptive analysis. In the evaluation, were considered the judge results 1 which have greater reliability. There was an improvement in the general level of vocal, roughness, and breathiness deviations from time point 4 [T4]. The prolonged /b/vocal exercise, combined with the vowel /e/ using chest- and arm-pushing exercises, was associated with an improvement in the overall grade of vocal deviation, roughness, and breathiness starting at minute 4 among patients who had undergone supracricoid laryngectomy with CHEP reconstruction. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Rover Attitude and Pointing System Simulation Testbed
NASA Technical Reports Server (NTRS)
Vanelli, Charles A.; Grinblat, Jonathan F.; Sirlin, Samuel W.; Pfister, Sam
2009-01-01
The MER (Mars Exploration Rover) Attitude and Pointing System Simulation Testbed Environment (RAPSSTER) provides a simulation platform used for the development and test of GNC (guidance, navigation, and control) flight algorithm designs for the Mars rovers, which was specifically tailored to the MERs, but has since been used in the development of rover algorithms for the Mars Science Laboratory (MSL) as well. The software provides an integrated simulation and software testbed environment for the development of Mars rover attitude and pointing flight software. It provides an environment that is able to run the MER GNC flight software directly (as opposed to running an algorithmic model of the MER GNC flight code). This improves simulation fidelity and confidence in the results. Further more, the simulation environment allows the user to single step through its execution, pausing, and restarting at will. The system also provides for the introduction of simulated faults specific to Mars rover environments that cannot be replicated in other testbed platforms, to stress test the GNC flight algorithms under examination. The software provides facilities to do these stress tests in ways that cannot be done in the real-time flight system testbeds, such as time-jumping (both forwards and backwards), and introduction of simulated actuator faults that would be difficult, expensive, and/or destructive to implement in the real-time testbeds. Actual flight-quality codes can be incorporated back into the development-test suite of GNC developers, closing the loop between the GNC developers and the flight software developers. The software provides fully automated scripting, allowing multiple tests to be run with varying parameters, without human supervision.
Assessing Freshman Engineering Students' Understanding of Ethical Behavior.
Henslee, Amber M; Murray, Susan L; Olbricht, Gayla R; Ludlow, Douglas K; Hays, Malcolm E; Nelson, Hannah M
2017-02-01
Academic dishonesty, including cheating and plagiarism, is on the rise in colleges, particularly among engineering students. While students decide to engage in these behaviors for many different reasons, academic integrity training can help improve their understanding of ethical decision making. The two studies outlined in this paper assess the effectiveness of an online module in increasing academic integrity among first semester engineering students. Study 1 tested the effectiveness of an academic honesty tutorial by using a between groups design with a Time 1- and Time 2-test. An academic honesty quiz assessed participants' knowledge at both time points. Study 2, which incorporated an improved version of the module and quiz, utilized a between groups design with three assessment time points. The additional Time 3-test allowed researchers to test for retention of information. Results were analyzed using ANCOVA and t tests. In Study 1, the experimental group exhibited significant improvement on the plagiarism items, but not the total score. However, at Time 2 there was no significant difference between groups after controlling for Time 1 scores. In Study 2, between- and within-group analyses suggest there was a significant improvement in total scores, but not plagiarism scores, after exposure to the tutorial. Overall, the academic integrity module impacted participants as evidenced by changes in total score and on specific plagiarism items. Although future implementation of the tutorial and quiz would benefit from modifications to reduce ceiling effects and improve assessment of knowledge, the results suggest such tutorial may be one valuable element in a systems approach to improving the academic integrity of engineering students.
Parental knowledge and metabolic control of children and young adults with type 1 diabetes
Mysliwiec, Malgorzata; Adamkiewicz-Drozynska, Elzbieta
2016-01-01
Introduction The authors aimed to answer the following questions: 1) What level of knowledge of type 1 diabetes do the parents of children and young adults with this disease have? 2) Will this level of knowledge increase after 1 year of observation? 3) Does improving the knowledge of young adults and their parents result in better metabolic control of the patients? Material and methods This study included 227 patients between the ages of 5 and 20 years with type 1 diabetes. The research was conducted from March 2009 to June 2011. The following two time points were examined: the beginning of the study (test 1a) and one year later (test 1b). The knowledge levels of the patients and parents were obtained using a survey and a knowledge test. Results Comparison of the results from the two study time points showed that the respondents had a significantly higher level of knowledge after 1 year (p = 0.001). The comparison of glycated hemoglobin levels between the two time points in patients with type 1 diabetes revealed that the levels were significantly higher at test 1b compared to test 1a (p = 0.0005). Conclusions The parents of children and young adults with type 1 diabetes demonstrate a satisfactory level of theoretical knowledge of therapeutic conduct and self-monitoring principles. The test 1b results demonstrated a higher level of theoretical knowledge in all respondents and poorer metabolic control. Poorer metabolic control in some patients suggests that metabolic control in type 1 diabetes depends on factors other than education. Further research is necessary to determine these additional factors. PMID:29379532
49 CFR 173.121 - Class 3-Assignment of packing group.
Code of Federal Regulations, 2012 CFR
2012-10-01
...) The viscosity and flash point are in accordance with the following table: Flow time t in seconds Jet... shall be performed are as follows: (i) Viscosity test. The flow time in seconds is determined at 23 °C...
Point-of-care HIV tests done by peers, Brazil
Dutra de Barros, Clarissa Habckost; Lobo, Tainah Dourado de Miranda; Pasini, Elisiane Nelcina; Comparini, Regina Aparecida; Caldas de Mesquita, Fábio
2016-01-01
Abstract Problem Early diagnosis of infections with human immunodeficiency virus (HIV) is needed – especially among key populations such as sex workers, transgender people, men who have sex with men and people who use drugs. Approach The Brazilian Ministry of Health developed a strategy called Viva Melhor Sabendo (“live better knowing”) to increase HIV testing among key populations. In partnership with nongovernmental organizations (NGOs), a peer point-of-care testing intervention, using an oral fluid rapid test, was introduced at social venues for key populations at different times of the day. Local setting Key populations in Brazil can have 40 times higher HIV prevalence than the general population (14.8% versus 0.4%). Relevant changes Legislation was reinterpreted, so that oral fluid rapid tests could be administered by any person trained in rapid testing by the health ministry. Between January 2014 and March 2015, 29 723 oral fluid tests were administered; 791 (2.7%) were positive. Among the key populations, transgender people had the greatest proportion of positive results (10.7%; 172/1612), followed by men who declared themselves as commercial sex workers (8.7%; 165/1889) and men who have sex with men (4.8%; 292/6055). Lessons learnt The strategy improved access to HIV testing. Testing done by peers at times and locations suitable for key populations increased acceptance of testing. Working with relevant NGOs is a useful approach when reaching out to these key populations. PMID:27516641
The universe of ANA testing: a case for point-of-care ANA testing.
Konstantinov, Konstantin N; Rubin, Robert L
2017-12-01
Testing for total antinuclear antibodies (ANA) is a critical tool for diagnosis and management of autoimmune diseases at both the primary care and subspecialty settings. Repurposing of ANA from a test for lupus to a test for any autoimmune condition has driven the increase in ANA requests. Changes in ANA referral patterns include early or subclinical autoimmune disease detection in patients with low pre-test probability and use of negative ANA results to rule out underlying autoimmune disease. A positive result can lead to further diagnostic considerations. Currently, ANA tests are performed in centralized laboratories; an alternative would be ANA testing at the clinical point-of-care (POC). By virtue of its near real-time data collection capability, low cost, and ease of use, we believe the POC ANA has the potential to enable a new paradigm shift in autoimmune serology testing.
Suarez-Kurtz, Guilherme; Ribeiro, Frederico Mota; Vicente, Flávio L.; Struchiner, Claudio J.
2001-01-01
Amoxicillin plasma concentrations (n = 1,152) obtained from 48 healthy subjects in two bioequivalence studies were used to develop limited-sampling strategy (LSS) models for estimating the area under the concentration-time curve (AUC), the maximum concentration of drug in plasma (Cmax), and the time interval of concentration above MIC susceptibility breakpoints in plasma (T>MIC). Each subject received 500-mg amoxicillin, as reference and test capsules or suspensions, and plasma concentrations were measured by a validated microbiological assay. Linear regression analysis and a “jack-knife” procedure revealed that three-point LSS models accurately estimated (R2, 0.92; precision, <5.8%) the AUC from 0 h to infinity (AUC0-∞) of amoxicillin for the four formulations tested. Validation tests indicated that a three-point LSS model (1, 2, and 5 h) developed for the reference capsule formulation predicts the following accurately (R2, 0.94 to 0.99): (i) the individual AUC0-∞ for the test capsule formulation in the same subjects, (ii) the individual AUC0-∞ for both reference and test suspensions in 24 other subjects, and (iii) the average AUC0-∞ following single oral doses (250 to 1,000 mg) of various amoxicillin formulations in 11 previously published studies. A linear regression equation was derived, using the same sampling time points of the LSS model for the AUC0-∞, but using different coefficients and intercept, for estimating Cmax. Bioequivalence assessments based on LSS-derived AUC0-∞'s and Cmax's provided results similar to those obtained using the original values for these parameters. Finally, two-point LSS models (R2 = 0.86 to 0.95) were developed for T>MICs of 0.25 or 2.0 μg/ml, which are representative of microorganisms susceptible and resistant to amoxicillin. PMID:11600352
Smoke-Point Properties of Nonbuoyant Round Laminar Jet Diffusion Flames
NASA Technical Reports Server (NTRS)
Urban, D. L.; Yuan, Z.-G.; Sunderland, R. B.; Lin, K.-C.; Dai, Z.; Faeth, G. M.
2000-01-01
The laminar smoke-point properties of nonbuoyant round laminar jet diffusion flames were studied emphasizing results from long duration (100-230 s) experiments at microgravity carried -out on- orbit in the Space Shuttle Columbia. Experimental conditions included ethylene-and propane-fueled flames burning in still air at an ambient temperature of 300 K, initial jet exit diameters of 1.6 and 2.7 mm, jet exit velocities of 170-1630 mm/s, jet exit Reynolds numbers of 46-172, characteristic flame residence times of 40-302 ms, and luminous flame lengths of 15-63 mm. The onset of laminar smoke-point conditions involved two flame configurations: closed-tip flames with first soot emissions along the flame axis and open-tip flames with first soot emissions from an annular ring about the flame axis. Open-tip flames were observed at large characteristic flame residence times with the onset of soot emissions associated with radiative quenching near the flame tip; nevertheless, unified correlations of laminar smoke-point properties were obtained that included both flame configurations. Flame lengths at laminar smoke-point conditions were well-correlated in terms of a corrected fuel flow rate suggested by a simplified analysis of flame shape. The present steady and nonbuoyant flames emitted soot more readily than earlier tests of nonbuoyant flames at microgravity using ground-based facilities and of buoyant flames at normal gravity due to reduced effects of unsteadiness, flame disturbances and buoyant motion. For example, laminar smoke-point flame lengths from ground-based microgravity measurements were up to 2.3 times longer and from buoyant flame measurements were up to 6.4 times longer than the present measurements at comparable conditions. Finally, present laminar smoke-point flame lengths were roughly inversely proportional to pressure, which is a somewhat slower variation than observed during earlier tests both at microgravity using ground-based facilities and at normal gravity.
Smoke-Point Properties of Nonbuoyant Round Laminar Jet Diffusion Flames. Appendix B
NASA Technical Reports Server (NTRS)
Urban, D. L.; Yuan, Z.-G.; Sunderland, P. B.; Lin, K.-C.; Dai, Z.; Faeth, G. M.; Ross, H. D. (Technical Monitor)
2000-01-01
The laminar smoke-point properties of non-buoyant round laminar jet diffusion flames were studied emphasizing results from long-duration (100-230 s) experiments at microgravity carried out in orbit aboard the space shuttle Columbia. Experimental conditions included ethylene- and propane-fueled flames burning in still air at an ambient temperature of 300 K, pressures of 35-130 kPa, jet exit diameters of 1.6 and 2.7 mm, jet exit velocities of 170-690 mm/s, jet exit Reynolds numbers of 46-172, characteristic flame residence times of 40-302 ms, and luminous flame lengths of 15-63 mm. Contrary to the normal-gravity laminar smoke point, in microgravity the onset of laminar smoke-point conditions involved two flame configurations: closed-tip flames with soot emissions along the flame axis and open-tip flames with soot emissions from an annular ring about the flame axis. Open-tip flames were observed at large characteristic flame residence times with the onset of soot emissions associated with radiative quenching near the flame tip: nevertheless, unified correlations of laminar smoke-point properties were obtained that included both flame configurations. Flame lengths at laminar smoke-point conditions were well correlated in terms of a corrected fuel flow rate suggested by a simplified analysis of flame shape. The present steady and nonbuoyant flames emitted soot more readily than non-buoyant flames in earlier tests using ground-based microgravity facilities and than buoyant flames at normal gravity, as a result of reduced effects of unsteadiness, flame disturbances, and buoyant motion. For example, present measurements of laminar smokepoint flame lengths at comparable conditions were up to 2.3 times shorter than ground-based microgravity measurements and up to 6.4 times shorter than buoyant flame measurements. Finally, present laminar smoke-point flame lengths were roughly inversely proportional to pressure to a degree that is a somewhat smaller than observed during earlier tests both at microgravity (using ground-based facilities) and at normal gravity,
NASA Technical Reports Server (NTRS)
Bautista, Abigail B.
1994-01-01
Twenty-four observers looked through a pair of 20 diopter wedge prisms and pointed to an image of a target which was displaced vertically from eye level by 6 cm at a distance of 30 cm. Observers pointed 40 times, using only their right hand, and received error-corrective feedback upon termination of each pointing response (terminal visual feedback). At three testing distances, 20, 30, and 40 cm, ten pre-exposure and ten post-exposure pointing responses were recorded for each hand as observers reached to a mirror-viewed target located at eye level. The difference between pre- and post-exposure pointing response (adaptive shift) was compared for both Exposed and Unexposed hands across all three testing distances. The data were assessed according to the results predicted by two alternative models for processing spatial-information: one using angular displacement information and another using linear displacement information. The angular model of spatial mapping best predicted the observer's pointing response for the Exposed hand. Although the angular adaptive shift did not change significantly as a function of distance (F(2,44) = 1.12, n.s.), the linear adaptive shift increased significantly over the three testing distances 02 44) = 4.90 p less than 0.01).
Robbins, C A; Breysse, P N
1996-08-01
This research evaluated the effect of the polarity of a second vapor on the adsorption of a polar and a nonpolar vapor using the Wheeler model. To examine the effect of polarity, it was also necessary to observe the effect of component boiling point. The 1% breakthrough time (1% tb), kinetic adsorption capacity (W(e)), and rate constant (kv) of the Wheeler model were determined for vapor challenges on carbon beds for both p-xylene and pyrrole (referred to as test vapors) individually, and in equimolar binary mixtures with the polar and nonpolar vapors toluene, p-fluorotoluene, o-dichlorobenzene, and p-dichlorobenzene (referred to as probe vapors). Probe vapor polarity (0 to 2.5 Debye) did not systematically alter the 1% tb, W(e), or kv of the test vapors. The 1% tb and W(e) for test vapors in binary mixtures can be estimated reasonably well, using the Wheeler model, from single-vapor data (1% tb +/- 30%, W(e) +/- 20%). The test vapor 1% tb depended mainly on total vapor concentration in both single and binary systems. W(e) was proportional to test vapor fractional molar concentration (mole fraction) in mixtures. The kv for p-xylene was significantly different (p < or = 0.001) when compared according to probe boiling point; however, these differences were apparently of limited importance in estimating 1% tb for the range of boiling points tested (111 to 180 degrees C). Although the polarity and boiling point of chemicals in the range tested are not practically important in predicting 1% tb with the Wheeler model, an effect due to probe boiling point is suggested, and tests with chemicals of more widely ranging boiling point are warranted. Since the 1% tb, and thus, respirator service life, depends mainly on total vapor concentration, these data underscore the importance of taking into account the presence of other vapors when estimating respirator service life for a vapor in a mixture.
A new comparison method for dew-point generators
NASA Astrophysics Data System (ADS)
Heinonen, Martti
1999-12-01
A new method for comparing dew-point generators was developed at the Centre for Metrology and Accreditation. In this method, the generators participating in a comparison are compared with a transportable saturator unit using a dew-point comparator. The method was tested by constructing a test apparatus and by comparing it with the MIKES primary dew-point generator several times in the dew-point temperature range from -40 to +75 °C. The expanded uncertainty (k = 2) of the apparatus was estimated to be between 0.05 and 0.07 °C and the difference between the comparator system and the generator is well within these limits. In particular, all of the results obtained in the range below 0 °C are within ±0.03 °C. It is concluded that a new type of a transfer standard with characteristics most suitable for dew-point comparisons can be developed on the basis of the principles presented in this paper.
Garashchuk, Sophya; Rassolov, Vitaly A
2008-07-14
Semiclassical implementation of the quantum trajectory formalism [J. Chem. Phys. 120, 1181 (2004)] is further developed to give a stable long-time description of zero-point energy in anharmonic systems of high dimensionality. The method is based on a numerically cheap linearized quantum force approach; stabilizing terms compensating for the linearization errors are added into the time-evolution equations for the classical and nonclassical components of the momentum operator. The wave function normalization and energy are rigorously conserved. Numerical tests are performed for model systems of up to 40 degrees of freedom.
A COMPACTRIO-BASED BEAM LOSS MONITOR FOR THE SNS RF TEST CAVE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blokland, Willem; Armstrong, Gary A
2009-01-01
An RF Test Cave has been built at the Spallation Neutron Source (SNS) to be able to test RF cavities without interfering the SNS accelerator operations. In addition to using thick concrete wall to minimize radiation exposure, a Beam Loss Monitor (BLM) must abort the operation within 100 usec when the integrated radiation within the cave exceeds a threshold. We choose the CompactRIO platform to implement the BLM based on its performance, cost-effectiveness, and rapid development. Each in/output module is connected through an FPGA to provide point-by-point processing. Every 10 usec the data is acquired analyzed and compared to themore » threshold. Data from the FPGA is transferred using DMA to the real-time controller, which communicates to a gateway PC to talk to the SNS control system. The system includes diagnostics to test the hardware and integrates the losses in real-time. In this paper we describe our design, implementation, and results« less
Wang, Fangnian; Tian, Yu; Chen, Lingjun; Luo, Robert; Sickler, Joanna; Liesenfeld, Oliver; Chen, Shuqi
2017-10-01
The performance of a polymerase chain reaction-based point-of-care assay, the cobas Strep A Nucleic Acid Test for use on the cobas Liat System (cobas Liat Strep A assay), for the detection of group A Streptococcus bacteria was evaluated in primary care settings. Throat swab specimens from 427 patients were tested with the cobas Liat Strep A assay and a rapid antigen detection test (RADT) by existing medical staff at 5 primary care clinics, and results were compared with bacterial culture. The cobas Liat Strep A assay demonstrated equivalent sensitivity (97.7%) and specificity (93.3%) to reference culture with a 15-minute turnaround time. In comparison to RADTs, the cobas Liat Strep A assay showed improved sensitivity (97.7% Liat vs 84.5% RADT). The Clinical Laboratory Improvement Amendments-waived cobas Liat Strep A assay demonstrated the ease of use and improved turnaround time of RADTs along with the sensitivity of culture.
Ting, Hui-Min; Chang, Liyun; Huang, Yu-Jie; Wu, Jia-Ming; Wang, Hung-Yu; Horng, Mong-Fong; Chang, Chun-Ming; Lan, Jen-Hong; Huang, Ya-Yu; Fang, Fu-Min; Leung, Stephen Wan
2014-01-01
Purpose The aim of this study was to develop a multivariate logistic regression model with least absolute shrinkage and selection operator (LASSO) to make valid predictions about the incidence of moderate-to-severe patient-rated xerostomia among head and neck cancer (HNC) patients treated with IMRT. Methods and Materials Quality of life questionnaire datasets from 206 patients with HNC were analyzed. The European Organization for Research and Treatment of Cancer QLQ-H&N35 and QLQ-C30 questionnaires were used as the endpoint evaluation. The primary endpoint (grade 3+ xerostomia) was defined as moderate-to-severe xerostomia at 3 (XER3m) and 12 months (XER12m) after the completion of IMRT. Normal tissue complication probability (NTCP) models were developed. The optimal and suboptimal numbers of prognostic factors for a multivariate logistic regression model were determined using the LASSO with bootstrapping technique. Statistical analysis was performed using the scaled Brier score, Nagelkerke R2, chi-squared test, Omnibus, Hosmer-Lemeshow test, and the AUC. Results Eight prognostic factors were selected by LASSO for the 3-month time point: Dmean-c, Dmean-i, age, financial status, T stage, AJCC stage, smoking, and education. Nine prognostic factors were selected for the 12-month time point: Dmean-i, education, Dmean-c, smoking, T stage, baseline xerostomia, alcohol abuse, family history, and node classification. In the selection of the suboptimal number of prognostic factors by LASSO, three suboptimal prognostic factors were fine-tuned by Hosmer-Lemeshow test and AUC, i.e., Dmean-c, Dmean-i, and age for the 3-month time point. Five suboptimal prognostic factors were also selected for the 12-month time point, i.e., Dmean-i, education, Dmean-c, smoking, and T stage. The overall performance for both time points of the NTCP model in terms of scaled Brier score, Omnibus, and Nagelkerke R2 was satisfactory and corresponded well with the expected values. Conclusions Multivariate NTCP models with LASSO can be used to predict patient-rated xerostomia after IMRT. PMID:24586971
Lee, Tsair-Fwu; Chao, Pei-Ju; Ting, Hui-Min; Chang, Liyun; Huang, Yu-Jie; Wu, Jia-Ming; Wang, Hung-Yu; Horng, Mong-Fong; Chang, Chun-Ming; Lan, Jen-Hong; Huang, Ya-Yu; Fang, Fu-Min; Leung, Stephen Wan
2014-01-01
The aim of this study was to develop a multivariate logistic regression model with least absolute shrinkage and selection operator (LASSO) to make valid predictions about the incidence of moderate-to-severe patient-rated xerostomia among head and neck cancer (HNC) patients treated with IMRT. Quality of life questionnaire datasets from 206 patients with HNC were analyzed. The European Organization for Research and Treatment of Cancer QLQ-H&N35 and QLQ-C30 questionnaires were used as the endpoint evaluation. The primary endpoint (grade 3(+) xerostomia) was defined as moderate-to-severe xerostomia at 3 (XER3m) and 12 months (XER12m) after the completion of IMRT. Normal tissue complication probability (NTCP) models were developed. The optimal and suboptimal numbers of prognostic factors for a multivariate logistic regression model were determined using the LASSO with bootstrapping technique. Statistical analysis was performed using the scaled Brier score, Nagelkerke R(2), chi-squared test, Omnibus, Hosmer-Lemeshow test, and the AUC. Eight prognostic factors were selected by LASSO for the 3-month time point: Dmean-c, Dmean-i, age, financial status, T stage, AJCC stage, smoking, and education. Nine prognostic factors were selected for the 12-month time point: Dmean-i, education, Dmean-c, smoking, T stage, baseline xerostomia, alcohol abuse, family history, and node classification. In the selection of the suboptimal number of prognostic factors by LASSO, three suboptimal prognostic factors were fine-tuned by Hosmer-Lemeshow test and AUC, i.e., Dmean-c, Dmean-i, and age for the 3-month time point. Five suboptimal prognostic factors were also selected for the 12-month time point, i.e., Dmean-i, education, Dmean-c, smoking, and T stage. The overall performance for both time points of the NTCP model in terms of scaled Brier score, Omnibus, and Nagelkerke R(2) was satisfactory and corresponded well with the expected values. Multivariate NTCP models with LASSO can be used to predict patient-rated xerostomia after IMRT.
The Legal Rights of Tenured and Part-Time Faculty Members in Higher Education.
ERIC Educational Resources Information Center
Corley, Sherie P.
A review of faculty-related court decisions in the areas of status, compensation, and unit determination points out legal rights of part-time and full-time faculty in higher education. These rights have been tested and defined by many court cases. Litigation has occurred about the difference between part-time and full-time faculty. In regard to…
Issa, Amine N; Herman, Nicole M; Wentz, Robert J; Taylor, Bryan J; Summerfield, Doug C; Johnson, Bruce D
2016-09-01
It is well documented that cognitive performance may be altered with ascent to altitude, but the association of various cognitive performance tests with symptoms of acute mountain sickness (AMS) is not well understood. Our objective was to assess and compare cognitive performance during a high-altitude expedition using several tests and to report the association of each test with AMS, headache, and quality of sleep. During an expedition to Mount Everest, 3 cognitive tests (Stroop, Trail Making, and the real-time cognitive assessment tool, an in-house developed motor accuracy test) were used along with a questionnaire to assess health and AMS. Eight team members were assessed pre-expedition, postexpedition, and at several time points during the expedition. There were no significant differences (P >.05) found among scores taken at 3 time points at base camp and the postexpedition scores for all 3 tests. Changes in the Stroop test scores were significantly associated with the odds of AMS (P <.05). The logistic regression results show that the percent change from baseline for Stroop score (β = -5.637; P = .032) and Stroop attempts (β = -5.269; P = .049) are significantly associated with the odds of meeting the criteria for AMS. No significant changes were found in overall cognitive performance at altitude, but a significant relationship was found between symptoms of AMS and performance in certain cognitive tests. This research shows the need for more investigation of objective physiologic assessments to associate with self-perceived metrics of AMS to gauge effect on cognitive performance. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.
The Use of Time Series Analysis and t Tests with Serially Correlated Data Tests.
ERIC Educational Resources Information Center
Nicolich, Mark J.; Weinstein, Carol S.
1981-01-01
Results of three methods of analysis applied to simulated autocorrelated data sets with an intervention point (varying in autocorrelation degree, variance of error term, and magnitude of intervention effect) are compared and presented. The three methods are: t tests; maximum likelihood Box-Jenkins (ARIMA); and Bayesian Box Jenkins. (Author/AEF)
Moles: Tool-Assisted Environment Isolation with Closures
NASA Astrophysics Data System (ADS)
de Halleux, Jonathan; Tillmann, Nikolai
Isolating test cases from environment dependencies is often desirable, as it increases test reliability and reduces test execution time. However, code that calls non-virtual methods or consumes sealed classes is often impossible to test in isolation. Moles is a new lightweight framework which addresses this problem. For any .NET method, Moles allows test-code to provide alternative implementations, given as .NET delegates, for which C# provides very concise syntax while capturing local variables in a closure object. Using code instrumentation, the Moles framework will redirect calls to provided delegates instead of the original methods. The Moles framework is designed to work together with the dynamic symbolic execution tool Pex to enable automated test generation. In a case study, testing code programmed against the Microsoft SharePoint Foundation API, we achieved full code coverage while running tests in isolation without an actual SharePoint server. The Moles framework integrates with .NET and Visual Studio.
ERIC Educational Resources Information Center
Paek, Insu; Park, Hyun-Jeong; Cai, Li; Chi, Eunlim
2014-01-01
Typically a longitudinal growth modeling based on item response theory (IRT) requires repeated measures data from a single group with the same test design. If operational or item exposure problems are present, the same test may not be employed to collect data for longitudinal analyses and tests at multiple time points are constructed with unique…
Cohen, Daniel M; Russo, Michael E; Jaggi, Preeti; Kline, Jennifer; Gluckman, William; Parekh, Amisha
2015-07-01
Rapid detection of group A beta-hemolytic streptococcus (GAS) is used routinely to help diagnose and treat pharyngitis. However, available rapid antigen detection tests for GAS have relatively low sensitivity, and backup testing is recommended in children. Newer assays are more sensitive yet require excessive time for practical point-of-care use as well as laboratory personnel. The Alere i strep A test is an isothermal nucleic acid amplification test designed to offer highly sensitive results at the point of care within 8 min when performed by nonlaboratory personnel. The performance of the Alere i strep A test was evaluated in a multicenter prospective trial in a Clinical Laboratory Improvement Amendments (CLIA)-waived setting in comparison to bacterial culture in 481 children and adults. Compared to culture, the Aleri i strep A test had 96.0% sensitivity and 94.6% specificity. Discrepant results were adjudicated by PCR and found the Alere i strep A test to have 98.7% sensitivity and 98.5% specificity. Overall, the Alere i strep A test could provide a one-step, rapid, point-of-care testing method for GAS pharyngitis and obviate backup testing on negative results. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Wi-Fi real time location systems
NASA Astrophysics Data System (ADS)
Doll, Benjamin A.
This thesis objective was to determine the viability of utilizing an untrained Wi-Fi. real time location system as a GPS alternative for indoor environments. Background. research showed that GPS is rarely able to penetrate buildings to provide reliable. location data. The benefit of having location information in a facility and how they might. be used for disaster or emergency relief personnel and their resources motivated this. research. A building was selected with a well-deployed Wi-Fi infrastructure and its. untrained location feature was used to determine the distance between the specified. test points and the system identified location. It was found that the average distance. from the test point throughout the facility was 14.3 feet 80% of the time. This fell within. the defined viable range and supported that an untrained Wi-Fi RTLS system could be a. viable solution for GPS's lack of availability indoors.
Somatotype and stress hormone levels in young soccer players.
Handziska, E; Handziski, Z; Gjorgoski, I; Dalip, M
2015-11-01
The relationship between somatotype and cortisol and adrenocorticotropic (ACTH) hormone concentrations at rest or after exercise in adolescent soccer players at different time points throughout a soccer season is not understood. Therefore, the aim of this study was to examine the relationship between somatotype and cortisol and ACTH concentrations at rest and after exercise in adolescent soccer players at different time points during a soccer season. During the first 4 months of the soccer season, 47 soccer players (between 15-17 years of age) were tested at three different time points including at baseline, after 6 weeks, and at the end of 4 months. Testing included anaerobic threshold (AnT, km/h) and maximal speed of running (Max, km/h) were measured with Conconi protocol on treadmill. Before and after a maximal exercise Test, plasma levels of cortisol (ug/dL) and ACTH (pg/ml) were assessed by chemiluminometry enzyme amplificated method. Heath-Carter anthropometric somatotype model was used to determine 13 elements of somatotype. Descriptive statistics and multiple regression were used for statistical analysis (P<0.05). Body composition and AnT were not significantly different between each time point of testing. The mesomorph-ectomorph (N.=21), balanced mesomorph (N.=8) and balanced ectomorph (N.=7) were the most frequent somatotypes. There were significant decrements of cortisol plasma levels (at rest 33.4%; after test 27.46%), with insignificant changes of ACTH plasma levels, after 6 weeks of preparation phase and after finishing of half season, at rest and after maximal treadmill test. There were significant correlation between ACTH levels at rest (R=0.44; P<0.01) and some somatotypes (mesomorph endomorph, central and balanced endomorph) and ACTH levels after maximal exercise test (R=0.36; P<0.05) and balanced ectomorph and endomorph mesomorph. There were significant correlation between cortisol levels after maximal exercise test at the beginning of training process (R=0.59; P<0.01) and some somatotypes (mesomorph ectomorph, mesomorph endomorph, balanced endomorph and endomorph mesomorph) and after the finishing of training process (R=0.62; P<0.01) and some somatotypes (central, balanced ectomorph and mesomorph ectomorph). The significant decreases of cortisol plasma levels during soccer training process could indicate a stagnation of training process, accordingly with insignificant changes of AnT. The significant correlations of some somatotypes with stress hormonal responses could only suggest that the somatotype characteristics of young soccer players could be of interest in process of selection and planning of soccer training process with an essential need for more studies.
Samaan, Michael A; Ringleb, Stacie I; Bawab, Sebastian Y; Greska, Eric K; Weinhandl, Joshua T
2018-03-01
The effects of ACL-reconstruction on lower extremity joint mechanics during performance of the Star Excursion Balance Test (SEBT) and Single Leg Hop (SLH) are limited. The purpose of this study was to determine if altered lower extremity mechanics occur during the SEBT and SLH after ACL-reconstruction. One female Division I collegiate athlete performed the SEBT and SLH tasks, bilaterally, both before ACL injury and 27 months after ACL-reconstruction. Maximal reach, hop distances, lower extremity joint kinematics and moments were compared between both time points. Musculoskeletal simulations were used to assess muscle force production during the SEBT and SLH at both time points. Compared to the pre-injury time point, SEBT reach distances were similar in both limbs after ACL-reconstruction except for the max anterior reach distance in the ipsilateral limb. The athlete demonstrated similar hop distances, bilaterally, after ACL-reconstruction compared to the pre-injury time point. Despite normal functional performance during the SEBT and SLH, the athlete exhibited altered lower extremity joint mechanics during both of these tasks. These results suggest that measuring the maximal reach and hop distances for these tasks, in combination with an analysis of the lower extremity joint mechanics that occur after ACL-reconstruction, may help clinicians and researchers to better understand the effects of ACL-reconstruction on the neuromuscular system during the SEBT and SLH.
Detection of Subtle Cognitive Changes after mTBI Using a Novel Tablet-Based Task.
Fischer, Tara D; Red, Stuart D; Chuang, Alice Z; Jones, Elizabeth B; McCarthy, James J; Patel, Saumil S; Sereno, Anne B
2016-07-01
This study examined the potential for novel tablet-based tasks, modeled after eye tracking techniques, to detect subtle sensorimotor and cognitive deficits after mild traumatic brain injury (mTBI). Specifically, we examined whether performance on these tablet-based tasks (Pro-point and Anti-point) was able to correctly categorize concussed versus non-concussed participants, compared with performance on other standardized tests for concussion. Patients admitted to the emergency department with mTBI were tested on the Pro-point and Anti-point tasks, a current standard cognitive screening test (i.e., the Standard Assessment of Concussion [SAC]), and another eye movement-based tablet test, the King-Devick(®) (KD). Within hours after injury, mTBI patients showed significant slowing in response times, compared with both orthopedic and age-matched control groups, in the Pro-point task, demonstrating deficits in sensorimotor function. Mild TBI patients also showed significant slowing, compared with both control groups, on the Anti-point task, even when controlling for sensorimotor slowing, indicating deficits in cognitive function. Performance on the SAC test revealed similar deficits of cognitive function in the mTBI group, compared with the age-matched control group; however, the KD test showed no evidence of cognitive slowing in mTBI patients, compared with either control group. Further, measuring the sensitivity and specificity of these tasks to accurately predict mTBI with receiver operating characteristic analysis indicated that the Anti-point and Pro-point tasks reached excellent levels of accuracy and fared better than current standardized tools for assessment of concussion. Our findings suggest that these rapid tablet-based tasks are able to reliably detect and measure functional impairment in cognitive and sensorimotor control within hours after mTBI. These tasks may provide a more sensitive diagnostic measure for functional deficits that could prove key to earlier detection of concussion, evaluation of interventions, or even prediction of persistent symptoms.
Detection of Subtle Cognitive Changes after mTBI Using a Novel Tablet-Based Task
Red, Stuart D.; Chuang, Alice Z.; Jones, Elizabeth B.; McCarthy, James J.; Patel, Saumil S.; Sereno, Anne B.
2016-01-01
Abstract This study examined the potential for novel tablet-based tasks, modeled after eye tracking techniques, to detect subtle sensorimotor and cognitive deficits after mild traumatic brain injury (mTBI). Specifically, we examined whether performance on these tablet-based tasks (Pro-point and Anti-point) was able to correctly categorize concussed versus non-concussed participants, compared with performance on other standardized tests for concussion. Patients admitted to the emergency department with mTBI were tested on the Pro-point and Anti-point tasks, a current standard cognitive screening test (i.e., the Standard Assessment of Concussion [SAC]), and another eye movement–based tablet test, the King-Devick® (KD). Within hours after injury, mTBI patients showed significant slowing in response times, compared with both orthopedic and age-matched control groups, in the Pro-point task, demonstrating deficits in sensorimotor function. Mild TBI patients also showed significant slowing, compared with both control groups, on the Anti-point task, even when controlling for sensorimotor slowing, indicating deficits in cognitive function. Performance on the SAC test revealed similar deficits of cognitive function in the mTBI group, compared with the age-matched control group; however, the KD test showed no evidence of cognitive slowing in mTBI patients, compared with either control group. Further, measuring the sensitivity and specificity of these tasks to accurately predict mTBI with receiver operating characteristic analysis indicated that the Anti-point and Pro-point tasks reached excellent levels of accuracy and fared better than current standardized tools for assessment of concussion. Our findings suggest that these rapid tablet-based tasks are able to reliably detect and measure functional impairment in cognitive and sensorimotor control within hours after mTBI. These tasks may provide a more sensitive diagnostic measure for functional deficits that could prove key to earlier detection of concussion, evaluation of interventions, or even prediction of persistent symptoms. PMID:26398492
NASA Astrophysics Data System (ADS)
Bilalic, Rusmir
A novel application of support vector machines (SVMs), artificial neural networks (ANNs), and Gaussian processes (GPs) for machine learning (GPML) to model microcontroller unit (MCU) upset due to intentional electromagnetic interference (IEMI) is presented. In this approach, an MCU performs a counting operation (0-7) while electromagnetic interference in the form of a radio frequency (RF) pulse is direct-injected into the MCU clock line. Injection times with respect to the clock signal are the clock low, clock rising edge, clock high, and the clock falling edge periods in the clock window during which the MCU is performing initialization and executing the counting procedure. The intent is to cause disruption in the counting operation and model the probability of effect (PoE) using machine learning tools. Five experiments were executed as part of this research, each of which contained a set of 38,300 training points and 38,300 test points, for a total of 383,000 total points with the following experiment variables: injection times with respect to the clock signal, injected RF power, injected RF pulse width, and injected RF frequency. For the 191,500 training points, the average training error was 12.47%, while for the 191,500 test points the average test error was 14.85%, meaning that on average, the machine was able to predict MCU upset with an 85.15% accuracy. Leaving out the results for the worst-performing model (SVM with a linear kernel), the test prediction accuracy for the remaining machines is almost 89%. All three machine learning methods (ANNs, SVMs, and GPML) showed excellent and consistent results in their ability to model and predict the PoE on an MCU due to IEMI. The GP approach performed best during training with a 7.43% average training error, while the ANN technique was most accurate during the test with a 10.80% error.
Teles, Fernando; Fonseca, Luís
2015-01-01
Accurate disease diagnosis in animals is crucial for animal well-being but also for preventing zoonosis transmission to humans. In particular, livestock diseases may constitute severe threats to humans due to the particularly high physical contact and exposure and, also, be the cause of important economic losses, even in non-endemic countries, where they often arise in the form of rapid and devastating epidemics. Rapid diagnostic tests have been used for a long time in field situations, particularly during outbreaks. However, they mostly rely on serological approaches, which may confirm the exposure to a particular pathogen but may be inappropriate for point-of-decision (point-of-care) settings when emergency responses supported on early and accurate diagnosis are required. Moreover, they often exhibit modest sensitivity and hence significantly depend on later result confirmation in central or reference laboratories. The impressive advances observed in recent years in materials sciences and in nanotechnology, as well as in nucleic-acid synthesis and engineering, have led to an outburst of new in-the-bench and prototype tests for nucleic-acid testing towards point-of-care diagnosis of genetic and infectious diseases. Manufacturing, commercial, regulatory, and technical nature issues for field applicability more likely have hindered their wider entrance into veterinary medicine and practice than have fundamental science gaps. This chapter begins by outlining the current situation, requirements, difficulties, and perspectives of point-of-care tests for diagnosing diseases of veterinary interest. Nucleic-acid testing, particularly for the point of care, is addressed subsequently. A range of valuable signal transduction mechanisms commonly employed in proof-of-concept schemes and techniques born on the analytical chemistry laboratories are also described. As the essential core of this chapter, sections dedicated to the principles and applications of microfluidics, lab-on-a-chip, and nanotechnology for the development of point-of-care tests are presented. Microdevices already applied or under development for application in field diagnosis of animal diseases are reviewed.
The fast multipole method and point dipole moment polarizable force fields.
Coles, Jonathan P; Masella, Michel
2015-01-14
We present an implementation of the fast multipole method for computing Coulombic electrostatic and polarization forces from polarizable force-fields based on induced point dipole moments. We demonstrate the expected O(N) scaling of that approach by performing single energy point calculations on hexamer protein subunits of the mature HIV-1 capsid. We also show the long time energy conservation in molecular dynamics at the nanosecond scale by performing simulations of a protein complex embedded in a coarse-grained solvent using a standard integrator and a multiple time step integrator. Our tests show the applicability of fast multipole method combined with state-of-the-art chemical models in molecular dynamical systems.
NASA Astrophysics Data System (ADS)
Kärcher, Hans J.; Kunz, Nans; Temi, Pasquale; Krabbe, Alfred; Wagner, Jörg; Süß, Martin
2014-07-01
The original pointing accuracy requirement of the Stratospheric Observatory for Infrared Astronomy SOFIA was defined at the beginning of the program in the late 1980s as very challenging 0.2 arcsec rms. The early science flights of the observatory started in December 2010 and the observatory has reached in the mean time nearly 0.7 arcsec rms, which is sufficient for most of the SOFIA science instruments. NASA and DLR, the owners of SOFIA, are planning now a future 4 year program to bring the pointing down to the ultimate 0.2 arcsec rms. This may be the right time to recall the history of the pointing requirement and its verification and the possibility of its achievement via early computer models and wind tunnel tests, later computer aided end-to-end simulations up to the first commissioning flights some years ago. The paper recollects the tools used in the different project phases for the verification of the pointing performance, explains the achievements and may give hints for the planning of the upcoming final pointing improvement phase.
Field test comparison of two dermal tolerance assessment methods of hand hygiene products.
Girard, R; Carré, E; Pires-Cronenberger, S; Bertin-Mandy, M; Favier-Bulit, M C; Coyault, C; Coudrais, S; Billard, M; Regard, A; Kerhoas, A; Valdeyron, M L; Cracco, B; Misslin, P
2008-06-01
This study aimed to compare the sensitivity and workload requirement of two dermal tolerance assessment methods of hand hygiene products, in order to select a suitable pilot testing method for field tests. An observer-rating method and a self-assessment method were compared in 12 voluntary hospital departments (autumn/winter of 2005-2006). Three test-periods of three weeks were separated by two-week intervals during which the routine products were reintroduced. The observer rating method scored dryness and irritation on four-point scales. In the self-assessment method, the user rated appearance, intactness, moisture content, and sensation on a visual analogue scale which was converted into a 10-point numerical scale. Eleven products (soaps) were tested (223/250 complete reports for observer rating, 131/251 for self-assessment). Two products were significantly less well tolerated than the routine product according to the observers, four products according to the self-assessments. There was no significant difference between the two methods when products were classified according to tolerance (Fisher's test: P=0.491). For the symptom common to both assessment methods (dryness), there is a good correlation between the two methods (Spearman's Rho: P=0.032). The workload was higher for observer rating method (288 h of observer time plus 122 h of prevention team and pharmacist time compared with 15 h of prevention team and pharmacist time for self-assessment). In conclusion, the self-assessment method was considered more suitable for pilot testing, although further time should be allocated for educational measures as the return rate of complete self-assessment forms was poor.
Application of time-reversal guided waves to field bridge testing for baseline-free damage diagnosis
NASA Astrophysics Data System (ADS)
Kim, S. B.; Sohn, H.
2006-03-01
There is ongoing research at Carnegie Mellon University to develop a "baseline-free" nondestructive evaluation technique. The uniqueness of this baseline-free diagnosis lies in that certain types of damage can be identified without direct comparison of test signals with previously stored baseline signals. By relaxing dependency on the past baseline data, false positive indications of damage, which might take place due to varying operational and environmental conditions of in-service structures, can be minimized. This baseline-free diagnosis technique is developed based on the concept of a time reversal process (TRP). According to the TRP, an input signal at an original excitation location can be reconstructed if a response signal obtained from another point is emitted back to the original point after being reversed in a time domain. Damage diagnosis lies in the premise that the time reversibility breaks down when a certain type of defect such as nonlinear damage exists along the wave propagation path. Then, the defect can be sensed by examining a reconstructed signal after the TRP. In this paper, the feasibility of the proposed NDT technique is investigated using actual test data obtained from the Buffalo Creek Bridge in Pennsylvania.
Real-time monitoring implementation in a remote-pumped WDM PON
NASA Astrophysics Data System (ADS)
Liaw, S.-K.; Hong, K.-L.; Shei, Y.-S.
2008-08-01
We report on an improved configuration to monitor a passive optical network with high quality in service. This proposed system comprises fiber-Bragg gratings, a 1 × 4 optical switch, and an optical time-domain reflectometry to diagnose the broken point in real time. It could simultaneously detect multioptical network units in a WDM PON. The remote-pump integrated residual pumping reused function is implemented. Broken points in different optical paths can be detected simultaneously even when the distances to the central office are identical. The bit-error rate testing is verified with a small power penalty, making it an ideal solution for the real-time monitoring in a WDM PON.
Long-term stability of CMV DNA in human breast milk.
Sam, Soya S; Ingersoll, Jessica; Racsa, Lori D; Caliendo, Angela M; Racsa, Patrick N; Igwe, Doris; Abdul-Ali, Deborah; Josephson, Cassandra; Kraft, Colleen S
2018-05-01
Human cytomegalovirus (CMV) is the leading cause of intrauterine and perinatal viral infection. The most common route of CMV transmission in newborns is through breastmilk and this can lead to infant morbidity and mortality. Breast milk that has been frozen for an extended period may need to be tested for CMV DNA to determine the source of infection. It has been a challenge for clinical laboratories to ensure the stability of CMV DNA in frozen breast milk for accurate viral load measurement. To evaluate the stability of CMV DNA in breast milk by testing quantitative viral loads over a 28-day period for breast milk stored at 4 °C and a 90-day period for breast milk stored at -20 °C. Baseline viral loads were determined on day 0 and the samples stored at 4 °C underwent extraction and amplification at four time points, up to 28 days. The samples stored at -20 °C underwent extraction and amplification at five time points up to 90 days. Log 10 values were calculated and t-test, Pearson's coefficient, and concordance correlation coefficient were calculated. There was no statistically significant difference between the time points by t-test, and correlation coefficients showed greater than 90% concordance for days 0 and 28 as well as days 0 and 90 at both storage temperatures tested. The concentration of CMV DNA in breast milk was stable for 28 days at 4 °C and 90 days at -20 °C as the concentrations did not differ significantly from the baseline viral loads. Copyright © 2018 Elsevier B.V. All rights reserved.
Hossner, Ernst-Joachim; Ehrlenspiel, Felix
2010-01-01
The paralysis-by-analysis phenomenon, i.e., attending to the execution of one's movement impairs performance, has gathered a lot of attention over recent years (see Wulf, 2007, for a review). Explanations of this phenomenon, e.g., the hypotheses of constrained action (Wulf et al., 2001) or of step-by-step execution (Masters, 1992; Beilock et al., 2002), however, do not refer to the level of underlying mechanisms on the level of sensorimotor control. For this purpose, a “nodal-point hypothesis” is presented here with the core assumption that skilled motor behavior is internally based on sensorimotor chains of nodal points, that attending to intermediate nodal points leads to a muscular re-freezing of the motor system at exactly and exclusively these points in time, and that this re-freezing is accompanied by the disruption of compensatory processes, resulting in an overall decrease of motor performance. Two experiments, on lever sequencing and basketball free throws, respectively, are reported that successfully tested these time-referenced predictions, i.e., showing that muscular activity is selectively increased and compensatory variability selectively decreased at movement-related nodal points if these points are in the focus of attention. PMID:21833285
Whitley, Heather P; Hanson, Courtney; Parton, Jason M
2017-03-01
This prospective longitudinal study compares diabetes screenings between standard practices vs systematically offered point-of-care (POC) hemoglobin A 1c (HbA 1c ) tests in patients aged 45 years or older. Systematically screened participants (n = 164) identified 63% (n = 104) with unknown hyperglycemia and 53% (n = 88) in prediabetes. The standard practice (n = 324) screened 22% (n = 73), most commonly by blood glucose (96%); 8% (n = 6) and 33% (n = 24) were found to have diabetes and prediabetes, respectively. The association between screening outcome and screening method was statistically significant ( P = 0.005) in favor of HbA 1C HbA 1c may be the most effective method to identify patients unknowingly living in hyperglycemia. Point-of-care tests further facilitate screening evaluation in a timely and feasible fashion. © 2017 Annals of Family Medicine, Inc.
NASA Astrophysics Data System (ADS)
Heiss, Walter Dieter; Wunner, Günter
2017-12-01
A matrix model that has been used to describe essential features of a parity-time symmetric set-up of three coupled wave guides is investigated. The emphasis of the study lies on the occurrence of an exceptional point of third order. It is demonstrated that the eigenfunctions in close vicinity of the exceptional point have a distinctive chiral behaviour. Using data describing realistic situations it is argued that such chiral behaviour can be tested experimentally.
Point-of-care oral-based diagnostics
Hart, RW; Mauk, MG; Liu, C; Qiu, X; Thompson, JA; Chen, D; Malamud, D; Abrams, WR; Bau, HH
2014-01-01
Many of the target molecules that reside in blood are also present in oral fluids, albeit at lower concentrations. Oral fluids are, however, relatively easy and safe to collect without the need for specialized equipment and training. Thus, oral fluids provide convenient samples for medical diagnostics. Recent advances in lab-on-a-chip technologies have made minute, fully integrated diagnostic systems practical for an assortment of point-of-care tests. Such systems can perform either immunoassays or molecular diagnostics outside centralized laboratories within time periods ranging from minutes to an hour. The article briefly reviews recent advances in devices for point-of-care testing with a focus on work that has been carried out by the authors as part of a NIH program. PMID:21521419
Neurocognitive Effects of Radiotherapy
2014-10-01
patients have completed a 4-5 hour neurocognitive testing assessment at baseline by Dr. Carol Armstrong. In addition , all patients have completed a 1...hour standard MRI as well as additional testing including diffuse tensor imaging (DTI), perfusion and diffusion. The majority of patients have...completed baseline and at least two additional time-points in regards to both neurocognitive testing and MRI. Eight patients have completed
Alles, Susan; Peng, Linda X; Mozola, Mark A
2009-01-01
A modification to Performance-Tested Method 010403, GeneQuence Listeria Test (DNAH method), is described. The modified method uses a new media formulation, LESS enrichment broth, in single-step enrichment protocols for both foods and environmental sponge and swab samples. Food samples are enriched for 27-30 h at 30 degrees C, and environmental samples for 24-48 h at 30 degrees C. Implementation of these abbreviated enrichment procedures allows test results to be obtained on a next-day basis. In testing of 14 food types in internal comparative studies with inoculated samples, there were statistically significant differences in method performance between the DNAH method and reference culture procedures for only 2 foods (pasteurized crab meat and lettuce) at the 27 h enrichment time point and for only a single food (pasteurized crab meat) in one trial at the 30 h enrichment time point. Independent laboratory testing with 3 foods showed statistical equivalence between the methods for all foods, and results support the findings of the internal trials. Overall, considering both internal and independent laboratory trials, sensitivity of the DNAH method relative to the reference culture procedures was 90.5%. Results of testing 5 environmental surfaces inoculated with various strains of Listeria spp. showed that the DNAH method was more productive than the reference U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) culture procedure for 3 surfaces (stainless steel, plastic, and cast iron), whereas results were statistically equivalent to the reference method for the other 2 surfaces (ceramic tile and sealed concrete). An independent laboratory trial with ceramic tile inoculated with L. monocytogenes confirmed the effectiveness of the DNAH method at the 24 h time point. Overall, sensitivity of the DNAH method at 24 h relative to that of the USDA-FSIS method was 152%. The DNAH method exhibited extremely high specificity, with only 1% false-positive reactions overall.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., if two groups (product A and a non-nutrient control) are tested at each of three points in time (day... groups: Group 1: Non-nutrient Control Group 2: Nutrient Control Group 3: Test Product 4.7.4.2The raw data... different from those of both the nutrient control (group 2) and the non-nutrient control (group 1) for those...
Code of Federal Regulations, 2011 CFR
2011-07-01
..., if two groups (product A and a non-nutrient control) are tested at each of three points in time (day... groups: Group 1: Non-nutrient Control Group 2: Nutrient Control Group 3: Test Product 4.7.4.2The raw data... different from those of both the nutrient control (group 2) and the non-nutrient control (group 1) for those...
Code of Federal Regulations, 2013 CFR
2013-07-01
..., if two groups (product A and a non-nutrient control) are tested at each of three points in time (day... groups: Group 1: Non-nutrient Control Group 2: Nutrient Control Group 3: Test Product 4.7.4.2The raw data... different from those of both the nutrient control (group 2) and the non-nutrient control (group 1) for those...
Code of Federal Regulations, 2010 CFR
2010-07-01
..., if two groups (product A and a non-nutrient control) are tested at each of three points in time (day... groups: Group 1: Non-nutrient Control Group 2: Nutrient Control Group 3: Test Product 4.7.4.2The raw data... different from those of both the nutrient control (group 2) and the non-nutrient control (group 1) for those...
Spaulding, Tammie J; Swartwout Szulga, Margaret; Figueroa, Cecilia
2012-04-01
The purpose of this study was to identify various U.S. state education departments' criteria for determining the severity of language impairment in children, with particular focus on the use of norm-referenced tests. A secondary objective was to determine if norm-referenced tests of child language were developed for the purpose of identifying the severity of children's language impairment. Published procedures for severity determinations were obtained from U.S. state education departments. In addition, manuals for 45 norm-referenced tests of child language were reviewed to determine if each test was designed to identify the degree of a child's language impairment. Consistency was evaluated among state criteria, test developers' intentions, and test characteristics. At the time of this study, 8 states published guidelines for determining the severity of language impairment, and each specified the use of norm-referenced tests for this purpose. The degree of use and cutoff-point criteria for severity determination varied across states. No cutoff-point criteria aligned with the severity cutoff points described within the test manuals. Furthermore, tests that included severity information lacked empirical data on how the severity categories were derived. Researchers and clinicians should be cautious in determining the severity of children's language impairment using norm-referenced test performance given the inconsistency in guidelines and lack of empirical data within test manuals to support this use.
Meyer, Brian K; Vargas, Diego
2006-01-01
The following study was conducted to determine the effect of different preservatives commonly used in the biopharmaceutical industry on the product-specific bubble point of sterilizing-grade filters when used to filter product processed with different types of tubing. The preservatives tested were 0.25% phenol, m-cresol, and benzyl alcohol. The tubing tested was Sani-Pure (platinum-cured silicone tubing), Versilic (peroxide-cured silicone tubing), C-Flex, Pharmed, and Cole-Parmer (BioPharm silicone tubing). The product-specific bubble point values of sterilizing grade filters were measured after the recirculation of product through the filter and tubing of different types of materials for a total contact time of 15 h. When silicone tubing was used, the post-recirculation product-specific bubble point was suppressed on average 13 psig when compared to the pre- recirculation product-specific bubble point. Suppression was also observed with C-Flex, but to a much lesser extent than with silicone tubing. Suppression was not observed with Pharmed or BioPharm tubing. Alcohol extractions performed on the filters that experienced suppressed bubble points followed by Fourier transform infrared spectroscopy analysis indicated the filters contained poly(dimethylsiloxane). Direct addition of poly(dimethlysiloxane) to solutions filtered through sterilizing-grade filters suppressed the filter bubble points when tested for integrity. Silicone oils most likely reduced the surface tension of the pores in the membrane, resulting in the ability of air (or nitrogen) to pass more freely through the membrane, causing suppressed bubble point test values. The results of these studies indicate that product-specific bubble point of a filter determined with only product may not reflect the true bubble point for preservative-containing products that are recirculated or contacted with certain tubing for 15 h or greater. In addition, tubing material placed in contact with products containing preservatives should be evaluated for impact to the product-specific bubble point when being utilized with sterilizing-grade filters.
An interpretation model of GPR point data in tunnel geological prediction
NASA Astrophysics Data System (ADS)
He, Yu-yao; Li, Bao-qi; Guo, Yuan-shu; Wang, Teng-na; Zhu, Ya
2017-02-01
GPR (Ground Penetrating Radar) point data plays an absolutely necessary role in the tunnel geological prediction. However, the research work on the GPR point data is very little and the results does not meet the actual requirements of the project. In this paper, a GPR point data interpretation model which is based on WD (Wigner distribution) and deep CNN (convolutional neural network) is proposed. Firstly, the GPR point data is transformed by WD to get the map of time-frequency joint distribution; Secondly, the joint distribution maps are classified by deep CNN. The approximate location of geological target is determined by observing the time frequency map in parallel; Finally, the GPR point data is interpreted according to the classification results and position information from the map. The simulation results show that classification accuracy of the test dataset (include 1200 GPR point data) is 91.83% at the 200 iteration. Our model has the advantages of high accuracy and fast training speed, and can provide a scientific basis for the development of tunnel construction and excavation plan.
Piloting a fiber optics and electronic theory curriculum with high school students
NASA Astrophysics Data System (ADS)
Gilchrist, Pamela O.; Carpenter, Eric D.; Gray-Battle, Asia
2014-07-01
Previous participants from a multi-year blended learning intervention focusing on science, technology, engineering and mathematics (STEM) content knowledge, technical, college, and career preparatory skills were recruited to pilot a new module designed by the project staff. Participants met for a total of 22 contact hours receiving lectures from staff and two guest speakers from industries relevant to photonics, fiber optics hands-on experimentation, and practice with documenting progress. Activities included constructing a fiber optics communication system, troubleshooting breadboard circuits and diagrammed circuits as well as hypothesis testing to discover various aspects of fiber optic cables. Participants documented their activities, wrote reflections on the content and learning endeavor and gave talks about their research experiences to staff, peers, and relatives during the last session. Overall, it was found that a significant gain in content knowledge occurred between the time of pre-testing (Mean=0.54) and post-testing time points for the fiber optics portion of the curriculum via the use of a paired samples t-test (Mean=0.71), t=-2.72, p<.05. Additionally, the electronic theory test results were not a normal distribution and for this reason non-parametric testing was used, specifically a Wilcoxon signed-ranks test. Results indicated a significant increase in content knowledge occurred over time between the pre- (Mdn=0.35) and post-testing time points (Mdn=0.80) z=-2.49, p<,05, r=-0.59 for the electronic theory portion of the curriculum. An equivalent control group was recruited from the remaining participant pool, allowing for comparison between groups. The program design, findings, and lessons learned will be reported in this paper.
Moments in time: metacognition, trust, and outcomes in dyadic negotiations.
Olekalns, Mara; Smith, Philip L
2005-12-01
This research tested the relationships between turning points, cognitive and affective trust, and negotiation outcomes. After completing a simulated negotiation, participants identified turning points from videotape. Turning points were then classified as substantive (interest, offer), characterization (positive, negative), or procedural (positive, negative). Prenegotiation affective trust predicted subsequent turning points, whereas prenegotiation cognitive trust did not, suggesting that different cues influence the two types of trust. Postnegotiation cognitive trust was increased by the occurrence of interest, positive characterization, and positive procedural turning points and decreased by negative characterization turning points. Affective trust was increased by positive procedural turning points. Finally, interest turning points resulted in higher joint outcomes, whereas negative characterization turning points resulted in lower joint outcomes. We conclude that there are two paths to building trust and increasing joint gain, one through insight and one through signaling good faith intentions.
Development of a preprototype times wastewater recovery subsystem, addendum
NASA Technical Reports Server (NTRS)
Dehner, G. F.
1984-01-01
Six tasks are described reflecting subsystem hardware and software modifications and test evaluation of a TIMES wastewater recovery subsystem. The overall results are illustrated in a figure which shows the water production rate, the specific energy corrected to 26.5 VDC, and the product water conductivity at various points in the testing. Four tasks are described reflecting studies performed to develop a preliminary design concept for a next generation TIMES. The overall results of the study are the completion of major design analyses and preliminary configuration layout drawings.
Villalar, J L; Arredondo, M T; Meneu, T; Traver, V; Cabrera, M F; Guillen, S; Del Pozo, F
2002-01-01
Centralized testing demands costly laboratories, which are inefficient and may provide poor services. Recent advances make it feasible to move clinical testing nearer to patients and the requesting physicians, thus reducing the time to treatment. Internet technologies can be used to create a virtual laboratory information system in a distributed health-care environment. This allows clinical testing to be transferred to a cooperative scheme of several point-of-care testing (POCT) nodes. Two pilot virtual laboratories were established, one in Italy (AUSL Modena) and one in Greece (Athens Medical Centre). They were constructed on a three-layer model to allow both technical and clinical verification. Different POCT devices were connected. The pilot sites produced good preliminary results in relation to user acceptance, efficiency, convenience and costs. Decentralized laboratories can be expected to become cost-effective.
FAMILIARITY TRANSFER AS AN EXPLANATION OF THE DÉJÀ VU EFFECT.
Małecki, M
2015-06-01
Déjà vu is often explained in terms of an unconscious transfer of familiarity between a familiar object or objects and accompanying new objects. However, empirical research tests more the priming effectiveness than such a transfer. This paper reviews the main explanations of déjà vu, proposes a cognitive model of the phenomenon, and tests its six major assumptions. The model states that a sense of familiarity can be felt toward an objectively new stimulus (point 1) and that it can be transferred from a known stimulus to a novel one (point 2) in a situation where the person is unaware of such a transfer (point 3). The criteria for déjà vu are that the known and the novel stimuli may have graphical or semantic similarity, but differences exclude priming explanations (point 4); the familiarity measure should be of an non-rational nature (sense of familiarity rather than recognition; point 5); and that the feeling of familiarity toward a novel stimuli produces a conflict, which could be measured by means of increased reaction (point 6). 119 participants were tested in three experiments. The participants were to assess the novel stimuli in terms of their sense of familiarity. The novel stimuli were primed or were not primed by the known stimulus (Exp. 1) or primed by the known vs a novel stimulus (Exp. 2 and 3). The priming was subliminal in all the experiments. Reaction times were measured in Exps. 2 and 3. The participants assessed the novel stimuli as more familiar when they were preceded by a known stimulus than when they were not (Exp. 1) or when they were preceded by a novel stimulus (Exps. 2 and 3). Reaction times were longer for assessments preceded by known stimulus than for assessments preceded by a novel stimulus, which contradicts the priming explanations. The results seem to support all six points of the proposed model of the mechanisms underlying the déjà vu experience.
Application of DPIV to Enhanced Mixing Heated Nozzle Flows
NASA Technical Reports Server (NTRS)
Wernet, Mark P.; Bridges, James
2002-01-01
Digital Particle Imaging Velocimetry (DPIV) is a planar velocity measurement technique that continues to be applied to new and challenging engineering research facilities while significantly reducing facility test time. DPIV was used in the GRC Nozzle Acoustic Test Rig (NATR) to characterize the high temperature (560 C), high speed (is greater than 500 m/s) flow field properties of mixing enhanced jet engine nozzles. The instantaneous velocity maps obtained using DPIV were used to determine mean velocity, rms velocity and two-point correlation statistics to verify the true turbulence characteristics of the flow. These measurements will ultimately be used to properly validate aeroacoustic model predictions by verifying CFD input to these models. These turbulence measurements have previously not been possible in hot supersonic jets. Mapping the nozzle velocity field using point based techniques requires over 60 hours of test time, compared to less than 45 minutes using DPIV, yielding a significant reduction in testing time. A dual camera DPIV configuration was used to maximize the field of view and further minimize the testing time required to map the nozzle flow. The DPIV system field of view covered 127 by 267 mm. Data were acquired at 19 axial stations providing coverage of the flow from the nozzle exit to 2.37 in downstream. At each measurement station, 400 image frame pairs were acquired from each camera. The DPIV measurements of the mixing enhanced nozzle designs illustrate the changes in the flow field resulting in the reduced noise signature.
Swathirajan, Chinnambedu Ravichandran; Vignesh, Ramachandran; Boobalan, Jayaseelan; Solomon, Sunil Suhas; Saravanan, Shanmugam; Balakrishnan, Pachamuthu
2017-10-01
Sustainable suppression of HIV replication forms the basis of anti-retroviral therapy (ART) medication. Thus, reliable quantification of HIV viral load has become an essential factor to monitor the effectiveness of the ART. Longer turnaround-time (TAT), batch testing and technical skills are major drawbacks of standard real-time PCR assays. The performance of the point-of-care Xpert HIV-1 viral load assay was evaluated against the Abbott RealTime PCR m2000rt system. A total of 96 plasma specimens ranging from 2.5 log10 copies ml -1 to 4.99 log10 copies ml -1 and proficiency testing panel specimens were used. Precision and accuracy were checked using the Pearson correlation co-efficient test and Bland-Altman analysis. Compared to the Abbott RealTime PCR, the Xpert HIV-1 viral load assay showed a good correlation (Pearson r=0.81; P<0.0001) with a mean difference of 0.27 log10 copies ml -1 (95 % CI, -0.41 to 0.96 log10 copies ml -1 ; sd, 0.35 log10 copies ml -1 ). Reliable and ease of testing individual specimens could make the Xpert HIV-1 viral load assay an efficient alternative method for ART monitoring in clinical management of HIV disease in resource-limited settings. The rapid test results (less than 2 h) could help in making an immediate clinical decision, which further strengthens patient care.
Repeated tracer tests in a karst system with concentrated allogenic recharge (Johnsbachtal, Austria)
NASA Astrophysics Data System (ADS)
Birk, Steffen; Wagner, Thomas; Pauritsch, Marcus; Winkler, Gerfried
2015-04-01
The Johnsbachtal (Austria) is a high Alpine headwater catchment covering an area of approximately 65 km², which is equipped with a hydrometeorological monitoring network (Strasser at al. 2013). The catchment is composed of carbonate rocks and crystalline rocks belonging to the Northern Calceraous Alps and the Greywacke Zone. The largest spring within the catchment, the Etzbach spring, is bound on karstified carbonate rocks of the Greywacke Zone. A stream sink located at a distance of approximately 1 km from the spring was used as injection point for repeated tracer tests in the years 2012, 2013, and 2014. In each case the tracer was recovered at the spring indicating an allogenic recharge component from the crystalline parts of the catchment. The spring discharge at the times of the three tracer tests varied between approximately 0.3 and 0.6 m³/s. Likewise the tracer travel times and thus the flow velocities were found to be different. Surprisingly, the largest tracer travel time (and thus lowest flow velocity) was obtained in 2013 when the spring discharge was highest (0.6 m³/s). In addition, the flow velocities in 2012 and 2014 were found to be clearly different, although the spring discharge was similar (roughly 0.3 m³/s) in both tests. Thus, the tracer velocity appears to be not correlated with the spring discharge. Field observations indicate that this finding can potentially be attributed to complexities at both the injection location (e.g., plugging of injection points and thus different flow paths) and the sampling point (i.e., the spring, which is composed of several outlet points representing different subcatchments). References: Strasser, U., Marke, T., Sass, O., Birk, S., Winkler, G. (2013): John's creek valley: a mountainous catchment for long-term interdisciplinary human-environment system research in Upper Styria (Austria). Environmental Earth Sciences, doi: 10.1007/s12665-013-2318-y
Halfon, Philippe; Ouzan, Denis; Khiri, Hacène; Pénaranda, Guillaume; Castellani, Paul; Oulès, Valerie; Kahloun, Asma; Amrani, Nolwenn; Fanteria, Lise; Martineau, Agnès; Naldi, Lou; Bourlière, Marc
2012-01-01
Background & Aims Point mutations in the coding region of the interleukin 28 gene (rs12979860) have recently been identified for predicting the outcome of treatment of hepatitis C virus infection. This polymorphism detection was based on whole blood DNA extraction. Alternatively, DNA for genetic diagnosis has been derived from buccal epithelial cells (BEC), dried blood spots (DBS), and genomic DNA from serum. The aim of the study was to investigate the reliability and accuracy of alternative routes of testing for single nucleotide polymorphism allele rs12979860CC. Methods Blood, plasma, and sera samples from 200 patients were extracted (400 µL). Buccal smears were tested using an FTA card. To simulate postal delay, we tested the influence of storage at ambient temperature on the different sources of DNA at five time points (baseline, 48 h, 6 days, 9 days, and 12 days) Results There was 100% concordance between blood, plasma, sera, and BEC, validating the use of DNA extracted from BEC collected on cytology brushes for genetic testing. Genetic variations in HPTR1 gene were detected using smear technique in blood smear (3620 copies) as well as in buccal smears (5870 copies). These results are similar to those for whole blood diluted at 1/10. A minimum of 0.04 µL, 4 µL, and 40 µL was necessary to obtain exploitable results respectively for whole blood, sera, and plasma. No significant variation between each time point was observed for the different sources of DNA. IL28B SNPs analysis at these different time points showed the same results using the four sources of DNA. Conclusion We demonstrated that genomic DNA extraction from buccal cells, small amounts of serum, and dried blood spots is an alternative to DNA extracted from peripheral blood cells and is helpful in retrospective and prospective studies for multiple genetic markers, specifically in hard-to-reach individuals. PMID:22412970
Testing deformation hypotheses by constraints on a time series of geodetic observations
NASA Astrophysics Data System (ADS)
Velsink, Hiddo
2018-01-01
In geodetic deformation analysis observations are used to identify form and size changes of a geodetic network, representing objects on the earth's surface. The network points are monitored, often continuously, because of suspected deformations. A deformation may affect many points during many epochs. The problem is that the best description of the deformation is, in general, unknown. To find it, different hypothesised deformation models have to be tested systematically for agreement with the observations. The tests have to be capable of stating with a certain probability the size of detectable deformations, and to be datum invariant. A statistical criterion is needed to find the best deformation model. Existing methods do not fulfil these requirements. Here we propose a method that formulates the different hypotheses as sets of constraints on the parameters of a least-squares adjustment model. The constraints can relate to subsets of epochs and to subsets of points, thus combining time series analysis and congruence model analysis. The constraints are formulated as nonstochastic observations in an adjustment model of observation equations. This gives an easy way to test the constraints and to get a quality description. The proposed method aims at providing a good discriminating method to find the best description of a deformation. The method is expected to improve the quality of geodetic deformation analysis. We demonstrate the method with an elaborate example.
Fully Convolutional Networks for Ground Classification from LIDAR Point Clouds
NASA Astrophysics Data System (ADS)
Rizaldy, A.; Persello, C.; Gevaert, C. M.; Oude Elberink, S. J.
2018-05-01
Deep Learning has been massively used for image classification in recent years. The use of deep learning for ground classification from LIDAR point clouds has also been recently studied. However, point clouds need to be converted into an image in order to use Convolutional Neural Networks (CNNs). In state-of-the-art techniques, this conversion is slow because each point is converted into a separate image. This approach leads to highly redundant computation during conversion and classification. The goal of this study is to design a more efficient data conversion and ground classification. This goal is achieved by first converting the whole point cloud into a single image. The classification is then performed by a Fully Convolutional Network (FCN), a modified version of CNN designed for pixel-wise image classification. The proposed method is significantly faster than state-of-the-art techniques. On the ISPRS Filter Test dataset, it is 78 times faster for conversion and 16 times faster for classification. Our experimental analysis on the same dataset shows that the proposed method results in 5.22 % of total error, 4.10 % of type I error, and 15.07 % of type II error. Compared to the previous CNN-based technique and LAStools software, the proposed method reduces the total error and type I error (while type II error is slightly higher). The method was also tested on a very high point density LIDAR point clouds resulting in 4.02 % of total error, 2.15 % of type I error and 6.14 % of type II error.
A scoring algorithm for predicting the presence of adult asthma: a prospective derivation study.
Tomita, Katsuyuki; Sano, Hiroyuki; Chiba, Yasutaka; Sato, Ryuji; Sano, Akiko; Nishiyama, Osamu; Iwanaga, Takashi; Higashimoto, Yuji; Haraguchi, Ryuta; Tohda, Yuji
2013-03-01
To predict the presence of asthma in adult patients with respiratory symptoms, we developed a scoring algorithm using clinical parameters. We prospectively analysed 566 adult outpatients who visited Kinki University Hospital for the first time with complaints of nonspecific respiratory symptoms. Asthma was comprehensively diagnosed by specialists using symptoms, signs, and objective tools including bronchodilator reversibility and/or the assessment of bronchial hyperresponsiveness (BHR). Multiple logistic regression analysis was performed to categorise patients and determine the accuracy of diagnosing asthma. A scoring algorithm using the symptom-sign score was developed, based on diurnal variation of symptoms (1 point), recurrent episodes (2 points), medical history of allergic diseases (1 point), and wheeze sound (2 points). A score of >3 had 35% sensitivity and 97% specificity for discriminating between patients with and without asthma and assigned a high probability of having asthma (accuracy 90%). A score of 1 or 2 points assigned intermediate probability (accuracy 68%). After providing additional data of forced expiratory volume in 1 second/forced vital capacity (FEV(1)/FVC) ratio <0.7, the post-test probability of having asthma was increased to 93%. A score of 0 points assigned low probability (accuracy 31%). After providing additional data of positive reversibility, the post-test probability of having asthma was increased to 88%. This pragmatic diagnostic algorithm is useful for predicting the presence of adult asthma and for determining the appropriate time for consultation with a pulmonologist.
Perfect Detection of Spikes in the Linear Sub-threshold Dynamics of Point Neurons
Krishnan, Jeyashree; Porta Mana, PierGianLuca; Helias, Moritz; Diesmann, Markus; Di Napoli, Edoardo
2018-01-01
Spiking neuronal networks are usually simulated with one of three main schemes: the classical time-driven and event-driven schemes, and the more recent hybrid scheme. All three schemes evolve the state of a neuron through a series of checkpoints: equally spaced in the first scheme and determined neuron-wise by spike events in the latter two. The time-driven and the hybrid scheme determine whether the membrane potential of a neuron crosses a threshold at the end of the time interval between consecutive checkpoints. Threshold crossing can, however, occur within the interval even if this test is negative. Spikes can therefore be missed. The present work offers an alternative geometric point of view on neuronal dynamics, and derives, implements, and benchmarks a method for perfect retrospective spike detection. This method can be applied to neuron models with affine or linear subthreshold dynamics. The idea behind the method is to propagate the threshold with a time-inverted dynamics, testing whether the threshold crosses the neuron state to be evolved, rather than vice versa. Algebraically this translates into a set of inequalities necessary and sufficient for threshold crossing. This test is slower than the imperfect one, but can be optimized in several ways. Comparison confirms earlier results that the imperfect tests rarely miss spikes (less than a fraction 1/108 of missed spikes) in biologically relevant settings. PMID:29379430
The effects of salmeterol on power output in nonasthmatic athletes.
McDowell, S L; Fleck, S J; Storms, W W
1997-04-01
Salmeterol xinafoate is a new aerosol inhalant that is used in the treatment of asthma. It is currently banned by the International Olympic Committee because of the concern that it may lend an unfair competitive advantage to the user. The purpose of this study was to determine whether salmeterol improves short-term anaerobic performance in elite nonasthmatic track cyclists. Eleven elite track cyclists volunteered to perform a 30-second all-out cycle ergometer test 3 hours after receiving either 42 micrograms of salmeterol xinafoate or placebo applied in a double-blind crossover procedure. During the ergometer test, peak power output, total work, time to peak power, and percent fatigue (decline in power output) were measured. Pulmonary measurements were also taken before and at various time points after inhalation and the ergometer test. A methacholine challenge was administered to each subject before participation in the study to ensure that none of the subjects had any reactive airway diseases. There were no significant differences (p > 0.05) between the placebo and salmeterol trials for peak power output, total work performed during the 30-second test, percent fatigue, and time to peak power. No differences between trials were observed for the pulmonary function test variables at any of the time points. Blood lactate concentrations before and after administration of drug or placebo were also not significantly different between trials. Additionally, salmeterol did not affect the maximal heart rate achieved during the test as compared with the placebo. Short-term salmeterol use within the prescribed dosage was not shown to increase short-term power output in nonasthmatic cyclists.
nu-Anomica: A Fast Support Vector Based Novelty Detection Technique
NASA Technical Reports Server (NTRS)
Das, Santanu; Bhaduri, Kanishka; Oza, Nikunj C.; Srivastava, Ashok N.
2009-01-01
In this paper we propose nu-Anomica, a novel anomaly detection technique that can be trained on huge data sets with much reduced running time compared to the benchmark one-class Support Vector Machines algorithm. In -Anomica, the idea is to train the machine such that it can provide a close approximation to the exact decision plane using fewer training points and without losing much of the generalization performance of the classical approach. We have tested the proposed algorithm on a variety of continuous data sets under different conditions. We show that under all test conditions the developed procedure closely preserves the accuracy of standard one-class Support Vector Machines while reducing both the training time and the test time by 5 - 20 times.
Newman, M; Newman, R; Hughes, T; Vadher, K; Barker, K L
2018-04-01
Timed loaded standing (TLS) is a suggested measure of back muscle endurance for people with vertebral osteoporosis. Surface electromyography revealed back muscles work harder and fatigue during TLS. The test end-point and total time were associated with back fatigue. The findings help demonstrate the concurrent validity of the TLS test. The TLS test is suggested as a measure of back muscle endurance for patients with vertebral osteoporosis. However, to date, no study has demonstrated that TLS does measure back extensor or erector spinae (ES) muscle endurance. We used surface electromyography (sEMG) to investigate the performance of the thoracic ES muscles during TLS. Thirty-six people with vertebral osteoporosis with a mean age of 71.6 (range 45-86) years participated. sEMG recordings were made of the ES at T3 and T12 bilaterally during quiet standing (QS) and TLS. The relative (%) change in sEMG amplitude between conditions was compared. Fatigue was evaluated by analysing the change in median frequency (MF) of the sEMG signal during TLS, and the correlation between maximal TLS time and rate of MF decline was examined. Activity in the ES increased significantly during TLS at all electrode locations. During TLS, the MF declined at a mean rate of -24.2% per minute (95% C.I. -26.5 to -21.9%). The MF slope and test time were strongly correlated (r 2 = 0.71), and at test end, the final MF dropped to an average 89% (95% C.I. 85 to 93%) of initial MF. Twenty-eight participants (78%) reported fatigue was the main reason for stopping, and for eight (22%), it was pain. This study demonstrates that TLS challenges the ES muscles in the thoracic region and results in ES fatigue. Endurance time and the point at which the TLS test ends are strongly related to ES fatigue.
Daniels, Roger L; Kim, Hyun Jung; Min, David B
2006-08-09
Soybean oil with an iodine value of 136 was hydrogenated to have iodine values of 126 and 117. The soybean oils with iodine values of 136, 126, and 117 were randomly interesterified using sodium methoxide. The oxidative stabilities of the hydrogenated and/or interesterified soybean oils were evaluated by measuring the headspace oxygen content by gas chromatography, and the induction time was measured using Rancimat. The melting points of the oils were evaluated by differential scanning calorimetry. Duncan's multiple range test of the headspace oxygen and induction time showed that hydrogenation increased the headspace oxygen content and induction time at alpha = 0.05. Interesterification decreased the headspace oxygen and the induction time for the soybean oils with iodine values of 136, 126, and 117 at alpha = 0.05. Hydrogenation increased the melting points as the iodine value decreased from 136 and 126 to 117 at alpha = 0.05. The random interesterification increased the melting points of soybean oils with iodine values of 136, 126, and 117 at alpha = 0.05. The combined effects of hydrogenation and interesterification increased the oxidative stability of soybean oil at alpha = 0.05 and the melting point at alpha = 0.01. The optimum combination of hydrogenation and random interesterification can improve the oxidative stability and increase the melting point to expand the application of soybean oil in foods.
The effects of cuing in time-shared tasks. [for aircraft flight route-way-point information
NASA Technical Reports Server (NTRS)
Chechile, R. A.; Sadoski, D. M.
1983-01-01
The results of two divided-attention experiments involving the editing of route-way-point displays on an avionics computer unit are reported. Two side tasks were required of the subjects, and either no cue, verbal cues appearing on the CRT, or symbolic cues (lights on the keyboard adjacent to keys to be used) were given to facilitate the primary editing task. Forty female and 30 male undergraduates were trained in the separate and combined tasks and divided randomly into groups of 25 for the cuing tests. A second test with three 10-subject groups was conducted at least one month later to investigate the efficacy of cuing for infrequently used procedures. It is found that only symbolic cuing significantly improved primary-task performance, increasing editing accuracy in the repetitive tests and reducing editing time in the delayed tests. Verbal cuing, probably because it requires additional cognitive effort, has no significant beneficial effect. These results are considered important for designing instruments for work environments requiring the performance of concurrent tasks, and as aircraft cockpits.
Valdez-González, Leticia A; Méndez-Padrón, Araceli; Gómez-Díaz, Rita A; Valladares-Salgado, Adán; Sánchez-Becerra, Martha Catalina; Mondragón-González, Rafael; Hernández-Rubí, Jaime; González-Hermosillo, Arturo; Cruz, Miguel; Borja, Víctor; Wacher, Niels H
The albumin-creatinine ratio is considered an indicator of microalbuminuria, precursor to chronic kidney disease, while HbA1c is used to measure glycemic control. Given the prevalence of diabetes-related nephropathy, spot testing of albumin has long been recommended as a preventative measure, for the timely detection of microalbuminuria. However, many countries do not have this testing available in primary care, and sometimes not even in second- and third-level care. The objective of this study was to compare agreement of the microalbuminuria and HbA1c results obtained in the laboratory with 'gold standard' techniques, with those obtained on site with a 'Point of Care' DCA Vantage™ device by Siemens. Results for the albumin-creatinine ratio and HbA1c from the Siemens DCA Vantage™ point of care device were compared with those from standard laboratory tests in 25 family medicine units in Mexico City and Toluca, State of Mexico, in patients diagnosed with type-2 diabetes. Agreement between the albumin values of the 2 tests was 0.745 (CI 95% 0.655-0.812). Agreement between the two measurement techniques for HbA1c was 0.970 (CI 95% 0.966-0.973). The results obtained were sufficiently comparative (R i = 0.74 for albumin-creatinine ratio and R i = 0.97 for HbA1c) to justify the use of the point of care device. Given the high agreement between the point of care device and laboratory tests, this device could be used to identify chronic kidney disease and glycemic control for more adequate treatment in patients with diabetes, especially in remote areas.
Computer Analysis of 400 HZ Aircraft Electrical Generator Test Data.
1980-06-01
Data Acquisition System. ............ 6 3 Voltage Waveform with Data Points. ....... 19 14 Zero Crossover Interpolation. ........ 20 5 Numerical...difference between successive positive-sloped zero crossovers of the waveform. However, the exact time of zero crossover is not known. This is because...data sampling and the generator output are not synchronized. This unsynchronization means that data points which correspond with an exact zero crossover
Bagis, Bora; Baltacioglu, Esra; Özcan, Mutlu; Ustaomer, Seda
2011-03-01
To investigate the persistence of staining after the use of chlorhexidine gluconate mouthrinse. Twenty-four subjects (nine women and 15 men) who underwent periodontal therapy and were prescribed the use of 0.2% chlorhexidine gluconate mouthrinse participated in this study. Color values of maxillary central incisors, canines, and first molars were recorded at baseline; 3 days; and 1, 2, and 3 weeks of twice-daily chlorhexidine gluconate use with a digital intraoral colorimeter according to the CIE L*a*b* coordinates. While color-change (Delta E) values showed significant differences (P=.020) at different time points (10.1, 8.9, 8.9, 9.4, after 3 days and 1, 2, and 3 weeks, respectively), the duration of chlorhexidine gluconate use did not significantly affect the results (P=.873) (two-way ANOVA, Tukey test). No significant difference was found among Delta L* (P=.070), Delta a* (P=.169), and Delta b* (P=.691) values at any time point (one-way ANOVA). Measurements of baseline to day 3 differences showed significantly higher Delta E values than those at other time points (P<.05), but this change remained nonsignificant after 1, 2, and 3 weeks of chlorhexidine gluconate use (P>.05) (Tukey test). The highest visible staining occurred on the first molars at all time points (83%, 79%, 79%, and 96% after 3 days and 1, 2, and 3 weeks, respectively) compared to the other teeth evaluated. The staining effect of chlorhexidine gluconate mouthrinse on natural dentition should be expected to be the highest in the first few days of use.
Information extraction from dynamic PS-InSAR time series using machine learning
NASA Astrophysics Data System (ADS)
van de Kerkhof, B.; Pankratius, V.; Chang, L.; van Swol, R.; Hanssen, R. F.
2017-12-01
Due to the increasing number of SAR satellites, with shorter repeat intervals and higher resolutions, SAR data volumes are exploding. Time series analyses of SAR data, i.e. Persistent Scatterer (PS) InSAR, enable the deformation monitoring of the built environment at an unprecedented scale, with hundreds of scatterers per km2, updated weekly. Potential hazards, e.g. due to failure of aging infrastructure, can be detected at an early stage. Yet, this requires the operational data processing of billions of measurement points, over hundreds of epochs, updating this data set dynamically as new data come in, and testing whether points (start to) behave in an anomalous way. Moreover, the quality of PS-InSAR measurements is ambiguous and heterogeneous, which will yield false positives and false negatives. Such analyses are numerically challenging. Here we extract relevant information from PS-InSAR time series using machine learning algorithms. We cluster (group together) time series with similar behaviour, even though they may not be spatially close, such that the results can be used for further analysis. First we reduce the dimensionality of the dataset in order to be able to cluster the data, since applying clustering techniques on high dimensional datasets often result in unsatisfying results. Our approach is to apply t-distributed Stochastic Neighbor Embedding (t-SNE), a machine learning algorithm for dimensionality reduction of high-dimensional data to a 2D or 3D map, and cluster this result using Density-Based Spatial Clustering of Applications with Noise (DBSCAN). The results show that we are able to detect and cluster time series with similar behaviour, which is the starting point for more extensive analysis into the underlying driving mechanisms. The results of the methods are compared to conventional hypothesis testing as well as a Self-Organising Map (SOM) approach. Hypothesis testing is robust and takes the stochastic nature of the observations into account, but is time consuming. Therefore, we successively apply our machine learning approach with the hypothesis testing approach in order to benefit from both the reduced computation time of the machine learning approach as from the robust quality metrics of hypothesis testing. We acknowledge support from NASA AISTNNX15AG84G (PI V. Pankratius)
NASA Astrophysics Data System (ADS)
Tuttas, S.; Braun, A.; Borrmann, A.; Stilla, U.
2014-08-01
For construction progress monitoring a planned state of the construction at a certain time (as-planed) has to be compared to the actual state (as-built). The as-planed state is derived from a building information model (BIM), which contains the geometry of the building and the construction schedule. In this paper we introduce an approach for the generation of an as-built point cloud by photogrammetry. It is regarded that that images on a construction cannot be taken from everywhere it seems to be necessary. Because of this we use a combination of structure from motion process together with control points to create a scaled point cloud in a consistent coordinate system. Subsequently this point cloud is used for an as-built - as-planed comparison. For that voxels of an octree are marked as occupied, free or unknown by raycasting based on the triangulated points and the camera positions. This allows to identify not existing building parts. For the verification of the existence of building parts a second test based on the points in front and behind the as-planed model planes is performed. The proposed procedure is tested based on an inner city construction site under real conditions.
Weissman-Miller, Deborah
2013-11-02
Point estimation is particularly important in predicting weight loss in individuals or small groups. In this analysis, a new health response function is based on a model of human response over time to estimate long-term health outcomes from a change point in short-term linear regression. This important estimation capability is addressed for small groups and single-subject designs in pilot studies for clinical trials, medical and therapeutic clinical practice. These estimations are based on a change point given by parameters derived from short-term participant data in ordinary least squares (OLS) regression. The development of the change point in initial OLS data and the point estimations are given in a new semiparametric ratio estimator (SPRE) model. The new response function is taken as a ratio of two-parameter Weibull distributions times a prior outcome value that steps estimated outcomes forward in time, where the shape and scale parameters are estimated at the change point. The Weibull distributions used in this ratio are derived from a Kelvin model in mechanics taken here to represent human beings. A distinct feature of the SPRE model in this article is that initial treatment response for a small group or a single subject is reflected in long-term response to treatment. This model is applied to weight loss in obesity in a secondary analysis of data from a classic weight loss study, which has been selected due to the dramatic increase in obesity in the United States over the past 20 years. A very small relative error of estimated to test data is shown for obesity treatment with the weight loss medication phentermine or placebo for the test dataset. An application of SPRE in clinical medicine or occupational therapy is to estimate long-term weight loss for a single subject or a small group near the beginning of treatment.
Jastrzębski, Zbigniew; Kiszałkiewicz, Justyna; Brzeziański, Michał; Pastuszak-Lewandoska, Dorota; Radzimińki, Łukasz; Brzeziańska-Lasota, Ewa; Jegier, Anna
2017-01-01
Recently studies have shown that, depending on the type of training and its duration, the expression levels of selected circulating myomiRNAs (c-miR-27a,b, c-miR-29a,b,c, c-miR-133a) differ and correlate with the physiological indicators of adaptation to physical activity. To analyse the expression of selected classes of miRNAs in soccer players during different periods of their training cycle. The study involved 22 soccer players aged 17-18 years. The multi-stage 20-m shuttle run test was used to estimate VO2 max among the soccer players. Samples serum were collected at baseline (time point I), after one week (time point II), and after 2 months of training (time point III). The analysis of the relative quantification (RQ) level of three exosomal myomiRNAs, c-miRNA-27b, c-miR-29a, and c-miR-133, was performed by quantitative polymerase chain reaction (qPCR) at three time points – before the training, after 1 week of training and after the completion of two months of competition season training. The expression analysis showed low expression levels (according to references) of all evaluated myomiRNAs before the training cycle. Analysis performed after a week of the training cycle and after completion of the entire training cycle showed elevated expression of all tested myomiRNAs. Statistical analysis revealed significant differences between the first and the second time point in soccer players for c-miR-27b and c-miR-29a; between the first and the third time point for c-miR-27b and c-miR-29a; and between the second and the third time point for c-miR-27b. Statistical analysis showed a positive correlation between the levels of c-miR-29a and VO2 max. Two months of training affected the expression of c-miR-27b and miR-29a in soccer players. The increased expression of c-miR-27b and c-miR-29 with training could indicate their probable role in the adaptation process that takes place in the muscular system. Possibly, the expression of c-miR-29a will be found to be involved in cardiorespiratory fitness in future research. PMID:29472735
Evaluating Diagnostic Point-of-Care Tests in Resource-Limited Settings
Drain, Paul K; Hyle, Emily P; Noubary, Farzad; Freedberg, Kenneth A; Wilson, Douglas; Bishai, William; Rodriguez, William; Bassett, Ingrid V
2014-01-01
Diagnostic point-of-care (POC) testing is intended to minimize the time to obtain a test result, thereby allowing clinicians and patients to make an expeditious clinical decision. As POC tests expand into resource-limited settings (RLS), the benefits must outweigh the costs. To optimize POC testing in RLS, diagnostic POC tests need rigorous evaluations focused on relevant clinical outcomes and operational costs, which differ from evaluations of conventional diagnostic tests. Here, we reviewed published studies on POC testing in RLS, and found no clearly defined metric for the clinical utility of POC testing. Therefore, we propose a framework for evaluating POC tests, and suggest and define the term “test efficacy” to describe a diagnostic test’s capacity to support a clinical decision within its operational context. We also proposed revised criteria for an ideal diagnostic POC test in resource-limited settings. Through systematic evaluations, comparisons between centralized diagnostic testing and novel POC technologies can be more formalized, and health officials can better determine which POC technologies represent valuable additions to their clinical programs. PMID:24332389
Kraus, Wayne A; Wagner, Albert F
1986-04-01
A triatomic classical trajectory code has been modified by extensive vectorization of the algorithms to achieve much improved performance on an FPS 164 attached processor. Extensive timings on both the FPS 164 and a VAX 11/780 with floating point accelerator are presented as a function of the number of trajectories simultaneously run. The timing tests involve a potential energy surface of the LEPS variety and trajectories with 1000 time steps. The results indicate that vectorization results in timing improvements on both the VAX and the FPS. For larger numbers of trajectories run simultaneously, up to a factor of 25 improvement in speed occurs between VAX and FPS vectorized code. Copyright © 1986 John Wiley & Sons, Inc.
Hart, Corey B.; Giszter, Simon F.
2013-01-01
We present and apply a method that uses point process statistics to discriminate the forms of synergies in motor pattern data, prior to explicit synergy extraction. The method uses electromyogram (EMG) pulse peak timing or onset timing. Peak timing is preferable in complex patterns where pulse onsets may be overlapping. An interval statistic derived from the point processes of EMG peak timings distinguishes time-varying synergies from synchronous synergies (SS). Model data shows that the statistic is robust for most conditions. Its application to both frog hindlimb EMG and rat locomotion hindlimb EMG show data from these preparations is clearly most consistent with synchronous synergy models (p < 0.001). Additional direct tests of pulse and interval relations in frog data further bolster the support for synchronous synergy mechanisms in these data. Our method and analyses support separated control of rhythm and pattern of motor primitives, with the low level execution primitives comprising pulsed SS in both frog and rat, and both episodic and rhythmic behaviors. PMID:23675341
Benoit, Daphne; Zhou, Xi K.; Pape, Jean W.; Peeling, Rosanna W.; Fitzgerald, Daniel W.; Mate, Kedar S.
2013-01-01
Background. Despite the availability of rapid diagnostic tests and inexpensive treatment for pregnant women, maternal-child syphilis transmission remains a leading cause of perinatal morbidity and mortality in developing countries. In Haiti, more than 3000 babies are born with congenital syphilis annually. Methods and Findings. From 2007 to 2011, we used a sequential time series, multi-intervention study design in fourteen clinics throughout Haiti to improve syphilis testing and treatment in pregnancy. The two primary interventions were the introduction of a rapid point-of-care syphilis test and systems strengthening based on quality improvement (QI) methods. Syphilis testing increased from 91.5% prediagnostic test to 95.9% after (P < 0.001) and further increased to 96.8% (P < 0.001) after the QI intervention. Despite high rates of testing across all time periods, syphilis treatment lagged behind and only increased from 70.3% to 74.7% after the introduction of rapid tests (P = 0.27), but it improved significantly from 70.2% to 84.3% (P < 0.001) after the systems strengthening QI intervention. Conclusion. Both point-of-care diagnostic testing and health systems-based quality improvement interventions can improve the delivery of specific evidence-based healthcare interventions to prevent congenital syphilis at scale in Haiti. Improved treatment rates for syphilis were seen only after the use of systems-based quality improvement approaches. PMID:26316955
Severe, Linda; Benoit, Daphne; Zhou, Xi K; Pape, Jean W; Peeling, Rosanna W; Fitzgerald, Daniel W; Mate, Kedar S
2013-01-01
Background. Despite the availability of rapid diagnostic tests and inexpensive treatment for pregnant women, maternal-child syphilis transmission remains a leading cause of perinatal morbidity and mortality in developing countries. In Haiti, more than 3000 babies are born with congenital syphilis annually. Methods and Findings. From 2007 to 2011, we used a sequential time series, multi-intervention study design in fourteen clinics throughout Haiti to improve syphilis testing and treatment in pregnancy. The two primary interventions were the introduction of a rapid point-of-care syphilis test and systems strengthening based on quality improvement (QI) methods. Syphilis testing increased from 91.5% prediagnostic test to 95.9% after (P < 0.001) and further increased to 96.8% (P < 0.001) after the QI intervention. Despite high rates of testing across all time periods, syphilis treatment lagged behind and only increased from 70.3% to 74.7% after the introduction of rapid tests (P = 0.27), but it improved significantly from 70.2% to 84.3% (P < 0.001) after the systems strengthening QI intervention. Conclusion. Both point-of-care diagnostic testing and health systems-based quality improvement interventions can improve the delivery of specific evidence-based healthcare interventions to prevent congenital syphilis at scale in Haiti. Improved treatment rates for syphilis were seen only after the use of systems-based quality improvement approaches.
Guan, Zheng; Zhang, Guan-min; Ma, Ping; Liu, Li-hong; Zhou, Tian-yan; Lu, Wei
2010-07-01
In this study, we evaluated the influence of different variance from each of the parameters on the output of tacrolimus population pharmacokinetic (PopPK) model in Chinese healthy volunteers, using Fourier amplitude sensitivity test (FAST). Besides, we estimated the index of sensitivity within whole course of blood sampling, designed different sampling times, and evaluated the quality of parameters' and the efficiency of prediction. It was observed that besides CL1/F, the index of sensitivity for all of the other four parameters (V1/F, V2/F, CL2/F and k(a)) in tacrolimus PopPK model showed relatively high level and changed fast with the time passing. With the increase of the variance of k(a), its indices of sensitivity increased obviously, associated with significant decrease in sensitivity index for the other parameters, and obvious change in peak time as well. According to the simulation of NONMEM and the comparison among different fitting results, we found that the sampling time points designed according to FAST surpassed the other time points. It suggests that FAST can access the sensitivities of model parameters effectively, and assist the design of clinical sampling times and the construction of PopPK model.
Stime, Katrina J; Garrett, Nigel; Sookrajh, Yukteshwar; Dorward, Jienchi; Dlamini, Ntuthu; Olowolagba, Ayo; Sharma, Monisha; Barnabas, Ruanne V; Drain, Paul K
2018-05-11
Many clinics in Southern Africa have long waiting times. The implementation of point-of-care (POC) tests to accelerate diagnosis and improve clinical management in resource-limited settings may improve or worsen clinic flow and waiting times. The objective of this study was to describe clinic flow with special emphasis on the impact of POC testing at a large urban public healthcare clinic in Durban, South Africa. We used time and motion methods to directly observe patients and practitioners. We created patient flow maps and recorded individual patient waiting and consultation times for patients seeking STI, TB, or HIV care. We conducted semi-structured interviews with 20 clinic staff to ascertain staff opinions on clinic flow and POC test implementation. Among 121 observed patients, the total number of queues ranged from 4 to 7 and total visit times ranged from 0:14 (hours:minutes) to 7:38. Patients waited a mean of 2:05 for standard-of-care STI management, and approximately 4:56 for STI POC diagnostic testing. Stable HIV patients who collected antiretroviral therapy refills waited a mean of 2:42 in the standard queue and 2:26 in the fast-track queue. A rapid TB test on a small sample of patients with the Xpert MTB/RIF assay and treatment initiation took a mean of 6:56, and 40% of patients presenting with TB-related symptoms were asked to return for an additional clinic visit to obtain test results. For all groups, the mean clinical assessment time with a nurse or physician was 7 to 9 min, which accounted for 2 to 6% of total visit time. Staff identified poor clinic flow and personnel shortages as areas of concern that may pose challenges to expanding POC tests in the current clinic environment. This busy urban clinic had multiple patient queues, long clinical visits, and short clinical encounters. Although POC testing ensured patients received a diagnosis sooner, it more than doubled the time STI patients spent at the clinic and did not result in same-day diagnosis for all patients screened for TB. Further research on implementing POC testing efficiently into care pathways is required to make these promising assays a success.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roper, J; Ghavidel, B; Godette, K
Purpose: To validate a knowledge-based algorithm for prostate LDR brachytherapy treatment planning. Methods: A dataset of 100 cases was compiled from an active prostate seed implant service. Cases were randomized into 10 subsets. For each subset, the 90 remaining library cases were registered to a common reference frame and then characterized on a point by point basis using principle component analysis (PCA). Each test case was converted to PCA vectors using the same process and compared with each library case using a Mahalanobis distance to evaluate similarity. Rank order PCA scores were used to select the best-matched library case. Themore » seed arrangement was extracted from the best-matched case and used as a starting point for planning the test case. Any subsequent modifications were recorded that required input from a treatment planner to achieve V100>95%, V150<60%, V200<20%. To simulate operating-room planning constraints, seed activity was held constant, and the seed count could not increase. Results: The computational time required to register test-case contours and evaluate PCA similarity across the library was 10s. Preliminary analysis of 2 subsets shows that 9 of 20 test cases did not require any seed modifications to obtain an acceptable plan. Five test cases required fewer than 10 seed modifications or a grid shift. Another 5 test cases required approximately 20 seed modifications. An acceptable plan was not achieved for 1 outlier, which was substantially larger than its best match. Modifications took between 5s and 6min. Conclusion: A knowledge-based treatment planning algorithm for prostate LDR brachytherapy is being cross validated using 100 prior cases. Preliminary results suggest that for this size library, acceptable plans can be achieved without planner input in about half of the cases while varying amounts of planner input are needed in remaining cases. Computational time and planning time are compatible with clinical practice.« less
Chiral dynamics in the low-temperature phase of QCD
NASA Astrophysics Data System (ADS)
Brandt, Bastian B.; Francis, Anthony; Meyer, Harvey B.; Robaina, Daniel
2014-09-01
We investigate the low-temperature phase of QCD and the crossover region with two light flavors of quarks. The chiral expansion around the point (T,m=0) in the temperature vs quark-mass plane indicates that a sharp real-time excitation exists with the quantum numbers of the pion. An exact sum rule is derived for the thermal modification of the spectral function associated with the axial charge density; the (dominant) pion pole contribution obeys the sum rule. We determine the two parameters of the pion dispersion relation using lattice QCD simulations and test the applicability of the chiral expansion. The time-dependent correlators are also analyzed using the maximum entropy method, yielding consistent results. Finally, we test the predictions of the chiral expansion around the point (T=0,m=0) for the temperature dependence of static observables.
Stepwise Regression Analysis of MDOE Balance Calibration Data Acquired at DNW
NASA Technical Reports Server (NTRS)
DeLoach, RIchard; Philipsen, Iwan
2007-01-01
This paper reports a comparison of two experiment design methods applied in the calibration of a strain-gage balance. One features a 734-point test matrix in which loads are varied systematically according to a method commonly applied in aerospace research and known in the literature of experiment design as One Factor At a Time (OFAT) testing. Two variations of an alternative experiment design were also executed on the same balance, each with different features of an MDOE experiment design. The Modern Design of Experiments (MDOE) is an integrated process of experiment design, execution, and analysis applied at NASA's Langley Research Center to achieve significant reductions in cycle time, direct operating cost, and experimental uncertainty in aerospace research generally and in balance calibration experiments specifically. Personnel in the Instrumentation and Controls Department of the German Dutch Wind Tunnels (DNW) have applied MDOE methods to evaluate them in the calibration of a balance using an automated calibration machine. The data have been sent to Langley Research Center for analysis and comparison. This paper reports key findings from this analysis. The chief result is that a 100-point calibration exploiting MDOE principles delivered quality comparable to a 700+ point OFAT calibration with significantly reduced cycle time and attendant savings in direct and indirect costs. While the DNW test matrices implemented key MDOE principles and produced excellent results, additional MDOE concepts implemented in balance calibrations at Langley Research Center are also identified and described.
Adams, Elisabeth J; Ehrlich, Alice; Turner, Katherine M E; Shah, Kunj; Macleod, John; Goldenberg, Simon; Meray, Robin K; Pearce, Vikki; Horner, Patrick
2014-07-23
We aimed to explore patient pathways using a chlamydia/gonorrhoea point-of-care (POC) nucleic acid amplification test (NAAT), and estimate and compare the costs of the proposed POC pathways with the current pathways using standard laboratory-based NAAT testing. Workshops were conducted with healthcare professionals at four sexual health clinics representing diverse models of care in the UK. They mapped out current pathways that used chlamydia/gonorrhoea tests, and constructed new pathways using a POC NAAT. Healthcare professionals' time was assessed in each pathway. The proposed POC pathways were then priced using a model built in Microsoft Excel, and compared to previously published costs for pathways using standard NAAT-based testing in an off-site laboratory. Pathways using a POC NAAT for asymptomatic and symptomatic patients and chlamydia/gonorrhoea-only tests were shorter and less expensive than most of the current pathways. Notably, we estimate that POC testing as part of a sexual health screen for symptomatic patients, or as stand-alone chlamydia/gonorrhoea testing, could reduce costs per patient by as much as £16 or £6, respectively. In both cases, healthcare professionals' time would be reduced by approximately 10 min per patient. POC testing for chlamydia/gonorrhoea in a clinical setting may reduce costs and clinician time, and may lead to more appropriate and quicker care for patients. Further study is warranted on how to best implement POC testing in clinics, and on the broader clinical and cost implications of this technology. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
El-Diasty, Mohammed; Pagiatakis, Spiros
2009-01-01
In this paper, we examine the effect of changing the temperature points on MEMS-based inertial sensor random error. We collect static data under different temperature points using a MEMS-based inertial sensor mounted inside a thermal chamber. Rigorous stochastic models, namely Autoregressive-based Gauss-Markov (AR-based GM) models are developed to describe the random error behaviour. The proposed AR-based GM model is initially applied to short stationary inertial data to develop the stochastic model parameters (correlation times). It is shown that the stochastic model parameters of a MEMS-based inertial unit, namely the ADIS16364, are temperature dependent. In addition, field kinematic test data collected at about 17 °C are used to test the performance of the stochastic models at different temperature points in the filtering stage using Unscented Kalman Filter (UKF). It is shown that the stochastic model developed at 20 °C provides a more accurate inertial navigation solution than the ones obtained from the stochastic models developed at -40 °C, -20 °C, 0 °C, +40 °C, and +60 °C. The temperature dependence of the stochastic model is significant and should be considered at all times to obtain optimal navigation solution for MEMS-based INS/GPS integration.
Baltierra, Nina B; Muessig, Kathryn E; Pike, Emily C; LeGrand, Sara; Bull, Sheana S; Hightow-Weidman, Lisa B
2016-02-01
There has been a rise in internet-based health interventions without a concomitant focus on new methods to measure user engagement and its effect on outcomes. We describe current user tracking methods for internet-based health interventions and offer suggestions for improvement based on the design and pilot testing of healthMpowerment.org (HMP). HMP is a multi-component online intervention for young Black men and transgender women who have sex with men (YBMSM/TW) to reduce risky sexual behaviors, promote healthy living and build social support. The intervention is non-directive, incorporates interactive features, and utilizes a point-based reward system. Fifteen YBMSM/TW (age 20-30) participated in a one-month pilot study to test the usability and efficacy of HMP. Engagement with the intervention was tracked using a customized data capture system and validated with Google Analytics. Usage was measured in time spent (total and across sections) and points earned. Average total time spent on HMP was five hours per person (range 0-13). Total time spent was correlated with total points earned and overall site satisfaction. Measuring engagement in internet-based interventions is crucial to determining efficacy. Multiple methods of tracking helped derive more comprehensive user profiles. Results highlighted the limitations of measures to capture user activity and the elusiveness of the concept of engagement. Copyright © 2016 Elsevier Inc. All rights reserved.
Sarquiz-Martínez, Brenda; González-Bonilla, César R; Santacruz-Tinoco, Clara Esperanza; Muñoz-Medina, José E; Pardavé-Alejandre, Héctor D; Barbosa-Cabrera, Elizabeth; Ramírez-González, José Ernesto; Díaz-Quiñonez, José Alberto
2017-01-01
Enterovirus (EV) and herpes simplex virus 1 and 2 (HSV1 and HSV2) are the main etiologic agents of central nervous system infections. Early laboratory confirmation of these infections is performed by viral culture of the cerebrospinal fluid (CSF), or the detection of specific antibodies in serum (e.g., HSV). The sensitivity of viral culture ranges from 65 to 75%, with a recovery time varying from 3 to 10 days. Serological tests are faster and easy to carry out, but they exhibit cross-reactivity between HSV1 and HSV2. Although molecular techniques are more sensitive (sensitivity >95%), they are more expensive and highly susceptible to cross-contamination. A real-time RT-PCR for the detection of EV, HSV1, and HSV2 was compared with end-point nested PCR. We tested 87 CSF samples of patients with a clinical diagnosis of viral meningitis or encephalitis. Fourteen samples were found to be positive by RT-PCR, but only 8 were positive by end-point PCR. The RT-PCR showed a specificity range of 94-100%, the negative predictive value was 100%, and the positive predictive value was 62, 100, and 28% for HSV1, HSV2, and EV, respectively. Real-time RT-PCR detected EV, HSV1, and HSV2 with a higher sensitivity and specificity than end-point nested RT-PCR. © 2017 S. Karger AG, Basel.
Gas-Dynamic Designing of the Exhaust System for the Air Brake
NASA Astrophysics Data System (ADS)
Novikova, Yu; Goriachkin, E.; Volkov, A.
2018-01-01
Each gas turbine engine is tested some times during the life-cycle. The test equipment includes the air brake that utilizes the power produced by the gas turbine engine. In actual conditions, the outlet pressure of the air brake does not change and is equal to atmospheric pressure. For this reason, for the air brake work it is necessary to design the special exhaust system. Mission of the exhaust system is to provide the required level of backpressure at the outlet of the air brake. The backpressure is required for the required power utilization by the air brake (the air brake operation in the required points on the performance curves). The paper is described the development of the gas dynamic canal, designing outlet guide vane and the creation of a unified exhaust system for the air brake. Using a unified exhaust system involves moving the operating point to the performance curve further away from the calculated point. However, the applying of one exhaust system instead of two will significantly reduce the cash and time costs.
High heat flux measurements and experimental calibrations/characterizations
NASA Technical Reports Server (NTRS)
Kidd, Carl T.
1992-01-01
Recent progress in techniques employed in the measurement of very high heat-transfer rates in reentry-type facilities at the Arnold Engineering Development Center (AEDC) is described. These advances include thermal analyses applied to transducer concepts used to make these measurements; improved heat-flux sensor fabrication methods, equipment, and procedures for determining the experimental time response of individual sensors; performance of absolute heat-flux calibrations at levels above 2,000 Btu/cu ft-sec (2.27 kW/cu cm); and innovative methods of performing in-situ run-to-run characterizations of heat-flux probes installed in the test facility. Graphical illustrations of the results of extensive thermal analyses of the null-point calorimeter and coaxial surface thermocouple concepts with application to measurements in aerothermal test environments are presented. Results of time response experiments and absolute calibrations of null-point calorimeters and coaxial thermocouples performed in the laboratory at intermediate to high heat-flux levels are shown. Typical AEDC high-enthalpy arc heater heat-flux data recently obtained with a Calspan-fabricated null-point probe model are included.
Suri, Gaurav; Sheppes, Gal; Leslie, Sara; Gross, James J
2014-12-01
To encourage an increase in daily activity, researchers have tried a variety of health-related communications, but with mixed results. In the present research-using the stair escalator choice context-we examined predictions derived from the Heuristic Systematic Model (HSM), Self Determination Theory (SDT), and related theories. Specifically, we tested whether (as predicted by HSM) signs that encourage heuristic processing ("Take the Stairs") would have greatest impact when placed at the stair/escalator point of choice (when processing time is limited), whereas signs that encourage systematic processing ("Will You Take the Stairs?") would have greatest impact when placed at some distance from the point of choice (when processing time is less limited). We also tested whether (as predicted by SDT) messages promoting autonomy would be more likely to result in sustained motivated behavior (i.e., stair taking at subsequent uncued choice points) than messages that use commands. A series of studies involving more than 9,000 pedestrians provided support for these predictions. (PsycINFO Database Record (c) 2014 APA, all rights reserved).
Auger, E.; D'Auria, L.; Martini, M.; Chouet, B.; Dawson, P.
2006-01-01
We present a comprehensive processing tool for the real-time analysis of the source mechanism of very long period (VLP) seismic data based on waveform inversions performed in the frequency domain for a point source. A search for the source providing the best-fitting solution is conducted over a three-dimensional grid of assumed source locations, in which the Green's functions associated with each point source are calculated by finite differences using the reciprocal relation between source and receiver. Tests performed on 62 nodes of a Linux cluster indicate that the waveform inversion and search for the best-fitting signal over 100,000 point sources require roughly 30 s of processing time for a 2-min-long record. The procedure is applied to post-processing of a data archive and to continuous automatic inversion of real-time data at Stromboli, providing insights into different modes of degassing at this volcano. Copyright 2006 by the American Geophysical Union.
Stein, Janine; Luppa, Melanie; Luck, Tobias; Maier, Wolfgang; Wagner, Michael; Daerr, Moritz; van den Bussche, Hendrik; Zimmermann, Thomas; Köhler, Mirjam; Bickel, Horst; Mösch, Edelgard; Weyerer, Siegfried; Kaufeler, Teresa; Pentzek, Michael; Wiese, Birgitt; Wollny, Anja; König, Hans-Helmut; Riedel-Heller, Steffi G
2012-01-01
The Consortium to Establish a Registry for Alzheimer's Disease-Neuropsychological (CERAD-NP) battery represents a commonly used neuropsychological instrument to measure cognitive functioning in the elderly. This study provides normative data for changes in cognitive function that normally occur in cognitively healthy individuals to interpret changes in CERAD-NP test scores over longer time periods. Longitudinal cohort study with three assessments at 1.5-year intervals over a period of 3 years. : Primary care medical record registry sample. As part of the German Study on Ageing, Cognition, and Dementia in Primary Care Patients, a sample of 1,450 cognitively healthy general practitioner patients, age 75 years and older, was assessed. Age-, education-, and gender-specific Reliable Change Indices (RCIs) were computed for a 90% confidence interval for selected subtests of the CERAD-NP battery. Across different age, education, and gender subgroups, changes from at least six to nine points in Verbal Fluency, four to eight points in Word List Memory, two to four points in Word List Recall, and one to four points in Word List Recognition indicated significant (i.e. reliable) changes in CERAD-NP test scores at the 90% confidence level. Furthermore, the calculation of RCIs for individual patients is demonstrated. Smaller changes in CERAD-NP test scores can be interpreted with only high uncertainty because of probable measurement error, practice effects, and normal age-related cognitive decline. This study, for the first time, provides age-, education-, and gender-specific CERAD-NP reference values on the basis of RCI methods for the interpretation of cognitive changes in older-age groups.
Real-time terrain storage generation from multiple sensors towards mobile robot operation interface.
Song, Wei; Cho, Seoungjae; Xi, Yulong; Cho, Kyungeun; Um, Kyhyun
2014-01-01
A mobile robot mounted with multiple sensors is used to rapidly collect 3D point clouds and video images so as to allow accurate terrain modeling. In this study, we develop a real-time terrain storage generation and representation system including a nonground point database (PDB), ground mesh database (MDB), and texture database (TDB). A voxel-based flag map is proposed for incrementally registering large-scale point clouds in a terrain model in real time. We quantize the 3D point clouds into 3D grids of the flag map as a comparative table in order to remove the redundant points. We integrate the large-scale 3D point clouds into a nonground PDB and a node-based terrain mesh using the CPU. Subsequently, we program a graphics processing unit (GPU) to generate the TDB by mapping the triangles in the terrain mesh onto the captured video images. Finally, we produce a nonground voxel map and a ground textured mesh as a terrain reconstruction result. Our proposed methods were tested in an outdoor environment. Our results show that the proposed system was able to rapidly generate terrain storage and provide high resolution terrain representation for mobile mapping services and a graphical user interface between remote operators and mobile robots.
Real-Time Terrain Storage Generation from Multiple Sensors towards Mobile Robot Operation Interface
Cho, Seoungjae; Xi, Yulong; Cho, Kyungeun
2014-01-01
A mobile robot mounted with multiple sensors is used to rapidly collect 3D point clouds and video images so as to allow accurate terrain modeling. In this study, we develop a real-time terrain storage generation and representation system including a nonground point database (PDB), ground mesh database (MDB), and texture database (TDB). A voxel-based flag map is proposed for incrementally registering large-scale point clouds in a terrain model in real time. We quantize the 3D point clouds into 3D grids of the flag map as a comparative table in order to remove the redundant points. We integrate the large-scale 3D point clouds into a nonground PDB and a node-based terrain mesh using the CPU. Subsequently, we program a graphics processing unit (GPU) to generate the TDB by mapping the triangles in the terrain mesh onto the captured video images. Finally, we produce a nonground voxel map and a ground textured mesh as a terrain reconstruction result. Our proposed methods were tested in an outdoor environment. Our results show that the proposed system was able to rapidly generate terrain storage and provide high resolution terrain representation for mobile mapping services and a graphical user interface between remote operators and mobile robots. PMID:25101321
An analytic data analysis method for oscillatory slug tests.
Chen, Chia-Shyun
2006-01-01
An analytical data analysis method is developed for slug tests in partially penetrating wells in confined or unconfined aquifers of high hydraulic conductivity. As adapted from the van der Kamp method, the determination of the hydraulic conductivity is based on the occurrence times and the displacements of the extreme points measured from the oscillatory data and their theoretical counterparts available in the literature. This method is applied to two sets of slug test response data presented by Butler et al.: one set shows slow damping with seven discernable extremities, and the other shows rapid damping with three extreme points. The estimates of the hydraulic conductivity obtained by the analytic method are in good agreement with those determined by an available curve-matching technique.
Dynamic analysis of suspension cable based on vector form intrinsic finite element method
NASA Astrophysics Data System (ADS)
Qin, Jian; Qiao, Liang; Wan, Jiancheng; Jiang, Ming; Xia, Yongjun
2017-10-01
A vector finite element method is presented for the dynamic analysis of cable structures based on the vector form intrinsic finite element (VFIFE) and mechanical properties of suspension cable. Firstly, the suspension cable is discretized into different elements by space points, the mass and external forces of suspension cable are transformed into space points. The structural form of cable is described by the space points at different time. The equations of motion for the space points are established according to the Newton’s second law. Then, the element internal forces between the space points are derived from the flexible truss structure. Finally, the motion equations of space points are solved by the central difference method with reasonable time integration step. The tangential tension of the bearing rope in a test ropeway with the moving concentrated loads is calculated and compared with the experimental data. The results show that the tangential tension of suspension cable with moving loads is consistent with the experimental data. This method has high calculated precision and meets the requirements of engineering application.
Multi-rate, real time image compression for images dominated by point sources
NASA Technical Reports Server (NTRS)
Huber, A. Kris; Budge, Scott E.; Harris, Richard W.
1993-01-01
An image compression system recently developed for compression of digital images dominated by point sources is presented. Encoding consists of minimum-mean removal, vector quantization, adaptive threshold truncation, and modified Huffman encoding. Simulations are presented showing that the peaks corresponding to point sources can be transmitted losslessly for low signal-to-noise ratios (SNR) and high point source densities while maintaining a reduced output bit rate. Encoding and decoding hardware has been built and tested which processes 552,960 12-bit pixels per second at compression rates of 10:1 and 4:1. Simulation results are presented for the 10:1 case only.
Rocketdyne Safety Algorithm: Space Shuttle Main Engine Fault Detection
NASA Technical Reports Server (NTRS)
Norman, Arnold M., Jr.
1994-01-01
The Rocketdyne Safety Algorithm (RSA) has been developed to the point of use on the TTBE at MSFC on Task 4 of LeRC contract NAS3-25884. This document contains a description of the work performed, the results of the nominal test of the major anomaly test cases and a table of the resulting cutoff times, a plot of the RSA value vs. time for each anomaly case, a logic flow description of the algorithm, the algorithm code, and a development plan for future efforts.
Point-Process Models of Social Network Interactions: Parameter Estimation and Missing Data Recovery
2014-08-01
treating them as zero will have a de minimis impact on the results, but avoiding computing them (and computing with them) saves tremendous time. Set a... test the methods on simulated time series on artificial social networks, including some toy networks and some meant to resemble IkeNet. We conclude...the section by discussing the results in detail. In each of our tests we begin with a complete data set, whether it is real (IkeNet) or simulated. Then
Post-retrieval extinction in adolescence prevents return of juvenile fear
Jones, Carolyn E.
2016-01-01
Traumatic experiences early in life can contribute to the development of mood and anxiety disorders that manifest during adolescence and young adulthood. In young rats exposed to acute fear or stress, alterations in neural development can lead to enduring behavioral abnormalities. Here, we used a modified extinction intervention (retrieval+extinction) during late adolescence (post-natal day 45 [p45]), in rats, to target auditory Pavlovian fear associations acquired as juveniles (p17 and p25). The effects of adolescent intervention were examined by assessing freezing as adults during both fear reacquisition and social transmission of fear from a cagemate. Rats underwent testing or training at three time points across development: juvenile (p17 or p25), adolescent (p45), and adult (p100). Retrieval+extinction during late adolescence prevented social reinstatement and recovery over time of fears initially acquired as juveniles (p17 and p25, respectively). Adolescence was the only time point tested here where retrieval+extinction prevented fear recall of associations acquired 20+ days earlier. PMID:27634147
McKeating, Cara; White, P Lewis; Posso, Raquel; Palmer, Michael; Johnson, Elizabeth; McMullan, Ronan
2018-05-01
Although treatment for candidaemia is time critical, culture-based tests prolong turnaround times and may promote underdiagnosis. Non-culture-based tests have the potential to overcome these difficulties but are in limited clinical use. The aim of this work was to undertake an initial evaluation of two non-culture-based tests for diagnosis of candidaemia. Patients with candidaemia were identified prospectively over a 4-month period. Sera drawn from case (candidaemic) and control (non-candidaemic) patients on the same day as the positive blood culture were tested with both the Renishaw RenDx Fungiplex test and a commercial β-d-glucan (BDG) assay (Fungitell, Associates of Cape Cod). Sensitivity and specificity were calculated independently and in combination, using paired blood culture as the reference standard. There were 10 eligible case patients and 39 negative controls. PCR sensitivity and specificity were found to be 44.4% (95% CI 18.9% to 73.3%) and 87.2% (72.8% to 94.8%), respectively. BDG sensitivity and specificity were 80% (47.9% to 95.4%) and 89.7% (75.9% to 96.5%), respectively. When combining PCR and BDG, sensitivity was 90% (95% CI 57.4% to 100%) and specificity was 79.5% (64.2% to 89.5%). When two sequential specimens were tested, PCR sensitivity increased to 60% (95% CI 31.2% to 83.3%) and BDG sensitivity to 90% (54.7% to 100%). A combination of tests, or a single test at multiple time points, may be preferable to relying on one test at a single time point. This should be accounted for in design of future diagnostic accuracy studies of tests for invasive candidosis. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
MPCM: a hardware coder for super slow motion video sequences
NASA Astrophysics Data System (ADS)
Alcocer, Estefanía; López-Granado, Otoniel; Gutierrez, Roberto; Malumbres, Manuel P.
2013-12-01
In the last decade, the improvements in VLSI levels and image sensor technologies have led to a frenetic rush to provide image sensors with higher resolutions and faster frame rates. As a result, video devices were designed to capture real-time video at high-resolution formats with frame rates reaching 1,000 fps and beyond. These ultrahigh-speed video cameras are widely used in scientific and industrial applications, such as car crash tests, combustion research, materials research and testing, fluid dynamics, and flow visualization that demand real-time video capturing at extremely high frame rates with high-definition formats. Therefore, data storage capability, communication bandwidth, processing time, and power consumption are critical parameters that should be carefully considered in their design. In this paper, we propose a fast FPGA implementation of a simple codec called modulo-pulse code modulation (MPCM) which is able to reduce the bandwidth requirements up to 1.7 times at the same image quality when compared with PCM coding. This allows current high-speed cameras to capture in a continuous manner through a 40-Gbit Ethernet point-to-point access.
A seamless acquisition digital storage oscilloscope with three-dimensional waveform display
NASA Astrophysics Data System (ADS)
Yang, Kuojun; Tian, Shulin; Zeng, Hao; Qiu, Lei; Guo, Lianping
2014-04-01
In traditional digital storage oscilloscope (DSO), sampled data need to be processed after each acquisition. During data processing, the acquisition is stopped and oscilloscope is blind to the input signal. Thus, this duration is called dead time. With the rapid development of modern electronic systems, the effect of infrequent events becomes significant. To capture these occasional events in shorter time, dead time in traditional DSO that causes the loss of measured signal needs to be reduced or even eliminated. In this paper, a seamless acquisition oscilloscope without dead time is proposed. In this oscilloscope, three-dimensional waveform mapping (TWM) technique, which converts sampled data to displayed waveform, is proposed. With this technique, not only the process speed is improved, but also the probability information of waveform is displayed with different brightness. Thus, a three-dimensional waveform is shown to the user. To reduce processing time further, parallel TWM which processes several sampled points simultaneously, and dual-port random access memory based pipelining technique which can process one sampling point in one clock period are proposed. Furthermore, two DDR3 (Double-Data-Rate Three Synchronous Dynamic Random Access Memory) are used for storing sampled data alternately, thus the acquisition can continue during data processing. Therefore, the dead time of DSO is eliminated. In addition, a double-pulse test method is adopted to test the waveform capturing rate (WCR) of the oscilloscope and a combined pulse test method is employed to evaluate the oscilloscope's capture ability comprehensively. The experiment results show that the WCR of the designed oscilloscope is 6 250 000 wfms/s (waveforms per second), the highest value in all existing oscilloscopes. The testing results also prove that there is no dead time in our oscilloscope, thus realizing the seamless acquisition.
A seamless acquisition digital storage oscilloscope with three-dimensional waveform display
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Kuojun, E-mail: kuojunyang@gmail.com; Guo, Lianping; School of Electrical and Electronic Engineering, Nanyang Technological University
In traditional digital storage oscilloscope (DSO), sampled data need to be processed after each acquisition. During data processing, the acquisition is stopped and oscilloscope is blind to the input signal. Thus, this duration is called dead time. With the rapid development of modern electronic systems, the effect of infrequent events becomes significant. To capture these occasional events in shorter time, dead time in traditional DSO that causes the loss of measured signal needs to be reduced or even eliminated. In this paper, a seamless acquisition oscilloscope without dead time is proposed. In this oscilloscope, three-dimensional waveform mapping (TWM) technique, whichmore » converts sampled data to displayed waveform, is proposed. With this technique, not only the process speed is improved, but also the probability information of waveform is displayed with different brightness. Thus, a three-dimensional waveform is shown to the user. To reduce processing time further, parallel TWM which processes several sampled points simultaneously, and dual-port random access memory based pipelining technique which can process one sampling point in one clock period are proposed. Furthermore, two DDR3 (Double-Data-Rate Three Synchronous Dynamic Random Access Memory) are used for storing sampled data alternately, thus the acquisition can continue during data processing. Therefore, the dead time of DSO is eliminated. In addition, a double-pulse test method is adopted to test the waveform capturing rate (WCR) of the oscilloscope and a combined pulse test method is employed to evaluate the oscilloscope's capture ability comprehensively. The experiment results show that the WCR of the designed oscilloscope is 6 250 000 wfms/s (waveforms per second), the highest value in all existing oscilloscopes. The testing results also prove that there is no dead time in our oscilloscope, thus realizing the seamless acquisition.« less
Effect of processing conditions on oil point pressure of moringa oleifera seed.
Aviara, N A; Musa, W B; Owolarafe, O K; Ogunsina, B S; Oluwole, F A
2015-07-01
Seed oil expression is an important economic venture in rural Nigeria. The traditional techniques of carrying out the operation is not only energy sapping and time consuming but also wasteful. In order to reduce the tedium involved in the expression of oil from moringa oleifera seed and develop efficient equipment for carrying out the operation, the oil point pressure of the seed was determined under different processing conditions using a laboratory press. The processing conditions employed were moisture content (4.78, 6.00, 8.00 and 10.00 % wet basis), heating temperature (50, 70, 85 and 100 °C) and heating time (15, 20, 25 and 30 min). Results showed that the oil point pressure increased with increase in seed moisture content, but decreased with increase in heating temperature and heating time within the above ranges. Highest oil point pressure value of 1.1239 MPa was obtained at the processing conditions of 10.00 % moisture content, 50 °C heating temperature and 15 min heating time. The lowest oil point pressure obtained was 0.3164 MPa and it occurred at the moisture content of 4.78 %, heating temperature of 100 °C and heating time of 30 min. Analysis of Variance (ANOVA) showed that all the processing variables and their interactions had significant effect on the oil point pressure of moringa oleifera seed at 1 % level of significance. This was further demonstrated using Response Surface Methodology (RSM). Tukey's test and Duncan's Multiple Range Analysis successfully separated the means and a multiple regression equation was used to express the relationship existing between the oil point pressure of moringa oleifera seed and its moisture content, processing temperature, heating time and their interactions. The model yielded coefficients that enabled the oil point pressure of the seed to be predicted with very high coefficient of determination.
Hilton, G; Unsworth, C A; Murphy, G C; Browne, M; Olver, J
2017-08-01
Longitudinal cohort design. First, to explore the longitudinal outcomes for people who received early intervention vocational rehabilitation (EIVR); second, to examine the nature and extent of relationships between contextual factors and employment outcomes over time. Both inpatient and community-based clients of a Spinal Community Integration Service (SCIS). People of workforce age undergoing inpatient rehabilitation for traumatic spinal cord injury were invited to participate in EIVR as part of SCIS. Data were collected at the following three time points: discharge and at 1 year and 2+ years post discharge. Measures included the spinal cord independence measure, hospital anxiety and depression scale, impact on participation and autonomy scale, numerical pain-rating scale and personal wellbeing index. A range of chi square, correlation and regression tests were undertaken to look for relationships between employment outcomes and demographic, emotional and physical characteristics. Ninety-seven participants were recruited and 60 were available at the final time point where 33% (95% confidence interval (CI): 24-42%) had achieved an employment outcome. Greater social participation was strongly correlated with wellbeing (ρ=0.692), and reduced anxiety (ρ=-0.522), depression (ρ=-0.643) and pain (ρ=-0.427) at the final time point. In a generalised linear mixed effect model, education status, relationship status and subjective wellbeing increased significantly the odds of being employed at the final time point. Tertiary education prior to injury was associated with eight times increased odds of being in employment at the final time point; being in a relationship at the time of injury was associated with increased odds of being in employment of more than 3.5; subjective wellbeing, while being the least powerful predictor was still associated with increased odds (1.8 times) of being employed at the final time point. EIVR shows promise in delivering similar return-to-work rates as those traditionally reported, but sooner. The dynamics around relationships, subjective wellbeing, social participation and employment outcomes require further exploration.
Barcelos, Filipe; Patto, José Vaz; Parente, Manuela; Medeiros, Dina; Sousa, Miguel; Figueiredo, Rui; Miguel, Cláudia; Teixeira, Ana
2009-01-01
To evaluate the applicability and utility of unstimulated syalometry and instruments of evaluation of sicca complaints in a Sjögren's syndrome outpatient clinic. We performed unstimulated syalometry to 45 consecutive Primary Sjögren's Syndrome patients (PSS) and 21 healthy asymptomatic individuals age and sex-matched. PSS patients were further evaluated with Schirmer's test. We applied 3 published questionnaires to PSS patients: Xerostomia Inventory (XI), Oral Health Impact Profile-short form (OHIP) and Ocular Surface Disease Index (OSDI), and correlated the results with syalometry and Schirmer's test. Statistical analysis was performed with SPSS (Mann-Whitney U-test and Spearman's correlation). Salivary flux was significantly lower in PSS patients, as compared to controls (0.08+/-0.01 ml/min versus 0.38+/-0.25 ml/min, p=0.000), and decreased with age. Syalometry didn't correlate with Schirmer's test. OHIP scores (mean 26.8 points, ranging from 2 to 43 for a maximum of 56 points) didn't correlate with syalometry neither with Schirmer's test, but showed an association with the XI (p<0.0005) and OSDI (p<0.0005) tests. The XI questionnaire (mean 28.4 points, ranging from 11 to 41 for a maximum of 44 points) correlated with syalometry (p=0.018), with the OHIP questionary (p<0.0005) and with the OSDI scale (p=0.004), although it didn't correlate with Schirmer's test. OSDI scores (mean 56.5 points, ranging from 7 to 90 for a maximum of 100 points) didn't correlate with Schirmer's test neither with syalometry, but associated with the XI (p=0.004) and OHIP (p<0.0005) scales. Unstimulated syalometry is useful in the evaluation of patients suspected of suffering from Sjögren's syndrome, since it can confirm salivary hypofunction in a quick and cheap manner, allowing to differentiate between healthy individuals and patients. In a specialized clinic, the immediate availability of a salivary functional test is important in the classification of PSS or sicca syndrome. The xerostomia and xerophtalmia impact scales were mutually concordant, and since they evaluate the effects of the disease through time, could be helpful in our daily consultation.
NASA Astrophysics Data System (ADS)
Halloran, Siobhan; Ristenpart, William
2013-11-01
Virologists and other researchers who test pathogens for airborne disease transmissibility often place a test animal downstream from an inoculated animal and later determine whether the test animal became infected. Despite the crucial role of the airflow in pathogen transmission between the animals, to date the infectious disease community has paid little attention to the effect of airspeed or turbulent intensity on the probability of transmission. Here we present measurements of the turbulent dispersivity under conditions relevant to experimental tests of airborne disease transmissibility between laboratory animals. We used time lapse photography to visualize the downstream transport and turbulent dispersion of smoke particulates released from a point source downstream of an axial fan, thus mimicking the release and transport of expiratory aerosols exhaled by an inoculated animal. We show that for fan-generated turbulence the plume width is invariant with the mean airspeed and, close to the point source, increases linearly with downstream position. Importantly, the turbulent dispersivity is insensitive to the presence of meshes placed downstream from the point source, indicating that the fan length scale dictates the turbulent intensity and corresponding dispersivity.
Sanli, Elizabeth A; Lee, Timothy D
2015-06-01
The influence of nominal and functional task difficulty during the acquisition of a motor skill was examined in two tests of transfer of learning. The task involved a ballistic, target-directed, finger action. Nominal task difficulty was defined as the distance of the target from the home position. Functional task difficulty was created by manipulating the progression of target distances during practice. Based on the challenge point framework (Guadagnoli & Lee, 2004), we predicted that practice with a set of targets farther away from the performer would benefit from less functional task difficulty, while practice with a closer set of targets would benefit from more functional task difficulty. In single-task transfer tests, learners who practiced using the high nominal task difficulty targets benefitted in terms of persistence of performance over time. In dual-task transfer tests, groups with an intermediate combined (nominal and functional) task difficulty performed with greater persistence over time on tests of transfer than those who practiced with the highest or lowest combined difficulty. Together these findings suggest that the influences of nominal and functional task difficulty during acquisition are weighted differentially depending upon the transfer test context. The challenge point framework does not accurately capture this complex relationship in its current form. Copyright © 2015 Elsevier B.V. All rights reserved.
Better together? Examining profiles of employee recovery experiences.
Bennett, Andrew A; Gabriel, Allison S; Calderwood, Charles; Dahling, Jason J; Trougakos, John P
2016-12-01
Employees are exposed to a wide variety of job demands that deplete personal resources and necessitate recovery. In light of this need, research on work recovery has focused on how distinct recovery experiences during postwork time relate to employee well-being. However, investigators have largely tested the effects of these experiences in isolation, neglecting the possibility that profiles of recovery experiences may exist and influence the recovery process. The current set of studies adopted a person-centered approach using latent profile analysis to understand whether unique constellations of recovery experiences-psychological detachment, relaxation, mastery, control, and problem-solving pondering-emerged for 2 samples of full-time employees. In Study 1, which involved a single-time-point assessment, we identified 4 unique profiles of recovery experiences, tested whether job demands (i.e., time pressure, role ambiguity) and job resources (i.e., job control) differentiated profile membership, and evaluated whether each profile uniquely related to employee well-being outcomes (i.e., emotional exhaustion, engagement, somatic complaints). In Study 2, which involved 2 time points, we replicated 3 of the 4 profiles observed in Study 1, and tested 2 additional antecedents rated by employees' supervisors: leader-member exchange and supervisor support for recovery. Across both studies, unique differences emerged in regard to antecedents and outcomes tied to recovery experience profile membership. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
NDE of hybrid armor structures using acoustography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandhu, Jaswinder S.; Pergantis, Charles G.
2011-06-23
The US Army is investigating the use of composite materials to deliver lightweight and more effective armor protection systems to soldiers and other army assets. However, widespread use of such hybrid armor will require a reliable but fast NDE methodology to ensure integrity of these components during manufacturing and while in service. Traditional ultrasonic inspection of such hybrid armor structures may prove to be very effective, but point-by-point ultrasonic scanning is inherently time-consuming and manufacturing slowdowns could develop in high-volume production of such armor systems. In this paper, we report on the application of acoustography for the NDE of hybridmore » armor structures. Acoustography differs from conventional ultrasonic testing in that test objects are inspected in full field, analogously to real time x-ray imaging. The approach uses a novel, super high resolution large area acousto-optic (AO) sensor, which allows image formation through simple ultrasound shadow casting, analogous to x-ray image formation. This NDE approach offers significant inspection speed advantage over conventional point-by-point ultrasonic scanning procedures and is well-suited for high volume production. We will report initial results on a number of hybrid armor plate specimens employing composite materials that are being investigated by the US Army. Acoustography NDE results will also be verified using other complimentary NDE methods.« less
America's Mediocre Test Scores: Education Crisis or Poverty Crisis?
ERIC Educational Resources Information Center
Petrilli, Michael J.; Wright, Brandon L.
2016-01-01
At a time when the national conversation is focused on lagging upward mobility, it is no surprise that many educators point to poverty as the explanation for mediocre test scores among U.S. students compared to those of students in other countries. If American teachers in struggling U.S. schools taught in Finland, says Finnish educator Pasi…
ERIC Educational Resources Information Center
Porter, Kristin E.
2016-01-01
In education research and in many other fields, researchers are often interested in testing the effectiveness of an intervention on multiple outcomes, for multiple subgroups, at multiple points in time, or across multiple treatment groups. The resulting multiplicity of statistical hypothesis tests can lead to spurious findings of effects. Multiple…
Does Television Rot Your Brain? New Evidence from the Coleman Study. NBER Working Paper No. 12021
ERIC Educational Resources Information Center
Gentzkow, Matthew; Shapiro, Jesse M.
2006-01-01
We use heterogeneity in the timing of television's introduction to different local markets to identify the effect of preschool television exposure on standardized test scores later in life. Our preferred point estimate indicates that an additional year of preschool television exposure raises average test scores by about .02 standard deviations. We…
Iapichino, Giacomo E; Bianchi, Paolo; Ranucci, Marco; Baryshnikova, Ekaterina
2017-06-01
Direct oral anticoagulants (DOACs) exert similar anticoagulant effects to vitamin K antagonists and are increasingly used worldwide. Nevertheless, an evidence-based approach to patients receiving DOACs when any unplanned urgent surgery or bleeding (either spontaneous or traumatic) occurs is still missing. In this review, we investigate the role of point-of-care coagulation tests when other, more specific tests are not available. Indeed, thromboelastography and activated clotting time can detect dabigatran-induced coagulopathy, while their accuracy is limited for apixaban and rivaroxaban, mostly in cases of low drug plasma concentrations. These tests can also be used to guide the reversal of DOAC-induced coagulopathy providing a quick, before-and-after picture in case of therapeutic use of hemostatic compounds. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Organic-inorganic hybrid foams with diatomite addition: Effect on functional properties
NASA Astrophysics Data System (ADS)
Verdolotti, L.; D'Auria, M.; Lavorgna, M.; Vollaro, P.; Iannace, S.; Capasso, I.; Galzerano, B.; Caputo, D.; Liguori, B.
2016-05-01
Organic-inorganic hybrid foams were prepared by using metakaolin, diatomite as a partial (or total) replacement of metakaolin, as matrix, silicon and whipped protein as pore forming. The foamed systems were hardened at defined temperature and time and then characterized by mechanical point of view through compression tests and by functional point of view through fire reaction and acoustic tests. The experimental findings highlighted that the replacement of diatomite in the formulation affected the morphological structure of the foams and consequently their mechanical properties. In particular, the consolidation mechanism in the diatomite based-hybrid foams changed from geopolymerization to a silicate polycondensation mechanism. Therefore, mechanical performances enhanced with increasing of the diatomite content. Fire reaction tests, such as non-combustibility and cone calorimeter tests, showed positive thermal inertia of samples regardless of the content of diatomite.
The Point-of-Care Laboratory in Clinical Microbiology
Michel-Lepage, Audrey; Boyer, Sylvie; Raoult, Didier
2016-01-01
SUMMARY Point-of-care (POC) laboratories that deliver rapid diagnoses of infectious diseases were invented to balance the centralization of core laboratories. POC laboratories operate 24 h a day and 7 days a week to provide diagnoses within 2 h, largely based on immunochromatography and real-time PCR tests. In our experience, these tests are conveniently combined into syndrome-based kits that facilitate sampling, including self-sampling and test operations, as POC laboratories can be operated by trained operators who are not necessarily biologists. POC laboratories are a way of easily providing clinical microbiology testing for populations distant from laboratories in developing and developed countries and on ships. Modern Internet connections enable support from core laboratories. The cost-effectiveness of POC laboratories has been established for the rapid diagnosis of tuberculosis and sexually transmitted infections in both developed and developing countries. PMID:27029593
Yang, J C; Noble, J
1990-01-01
This study investigated the validity of three American College Testing-Proficiency Examination Program (ACT-PEP) tests (Maternal and Child Nursing, Psychiatric/Mental Health Nursing, Adult Nursing) for predicting the academic performance of registered nurses (RNs) enrolled in bachelor's degree BSN programs nationwide. This study also examined RN students' performance on the ACT-PEP tests by their demographic characteristics: student's age, sex, race, student status (full- or part-time), and employment status (full- or part-time). The total sample for the three tests comprised 2,600 students from eight institutions nationwide. The median correlation coefficients between the three ACT-PEP tests and the semester grade point averages ranged from .36 to .56. Median correlation coefficients increased over time, supporting the stability of ACT-PEP test scores for predicting academic performance over time. The relative importance of selected independent variables for predicting academic performance was also examined; the most important variable for predicting academic performance was typically the ACT-PEP test score. Across the institutions, student demographic characteristics did not contribute significantly to explaining academic performance, over and above ACT-PEP scores.
Cutbush, Stacey; Williams, Jason; Miller, Shari
2016-11-01
This longitudinal study tested whether sexual harassment perpetration mediates the relationship between bullying perpetration and teen dating violence (TDV) perpetration and tested moderated mediation by assessing whether the developmental pathway varies by gender among middle school-aged youth. Although TDV has been associated with bullying and sexual harassment, the developmental relationship among all three behaviors has rarely been examined, especially by gender. The data were collected from one cohort of seventh grade middle school students (N = 612) from four schools. Students were surveyed every 6 months during seventh and eighth grades for a total of four waves of data collection. Structural equation modeling (SEM) was conducted to address the study aims, consisting of three stages: measurement models, mediation, and moderated mediation (otherwise known as Contrast of Mediated Effects). Results indicate no evidence of mediation. However, in the overall model, bullying and sexual harassment both emerged as significant predictors of TDV at a later time point. Among girls, only bullying significantly predicted TDV at a later time point, and, among boys, only sexual harassment significantly predicted TDV at a later time point. Prevention programs that target bullying and sexual harassment perpetration may reduce later perpetration of TDV. Further research is needed to disentangle the temporal relationships between these aggressive behaviors among youth.
Effects of time and sampling location on concentrations of β-hydroxybutyric acid in dairy cows.
Mahrt, A; Burfeind, O; Heuwieser, W
2014-01-01
Two trials were conducted to examine factors potentially influencing the measurement of blood β-hydroxybutyric acid (BHBA) in dairy cows. The objective of the first trial was to study effects of sampling time on BHBA concentration in continuously fed dairy cows. Furthermore, we determined test characteristics of a single BHBA measurement at a random time of the day to diagnose subclinical ketosis considering commonly used cut-points (1.2 and 1.4 mmol/L). Finally, we set out to evaluate if test characteristics could be enhanced by repeating measurements after different time intervals. During 4 herd visits, a total of 128 cows (8 to 28 d in milk) fed 10 times daily were screened at 0900 h and preselected by BHBA concentration. Blood samples were drawn from the tail vessels and BHBA concentrations were measured using an electronic BHBA meter (Precision Xceed, Abbott Diabetes Care Ltd., Witney, UK). Cows with BHBA concentrations ≥0.8 mmol/L at this time were enrolled in the trial (n=92). Subsequent BHBA measurements took place every 3h for a total of 8 measurements during 24 h. The effect of sampling time on BHBA concentrations was tested in a repeated-measures ANOVA repeating sampling time. Sampling time did not affect BHBA concentrations in continuously fed dairy cows. Defining the average daily BHBA concentration calculated from the 8 measurements as the gold standard, a single measurement at a random time of the day to diagnose subclinical ketosis had a sensitivity of 0.90 or 0.89 at the 2 BHBA cut-points (1.2 and 1.4 mmol/L). Specificity was 0.88 or 0.90 using the same cut-points. Repeating measurements after different time intervals improved test characteristics only slightly. In the second experiment, we compared BHBA concentrations of samples drawn from 3 different blood sampling locations (tail vessels, jugular vein, and mammary vein) of 116 lactating dairy cows. Concentrations of BHBA differed in samples from the 3 sampling locations. Mean BHBA concentration was 0.3 mmol/L lower when measured in the mammary vein compared with the jugular vein and 0.4 mmol/L lower in the mammary vein compared with the tail vessels. We conclude that to measure BHBA, blood samples of continuously fed dairy cows can be drawn at any time of the day. A single measurement provides very good test characteristics for on-farm conditions. Blood samples for BHBA measurement should be drawn from the jugular vein or tail vessels; the mammary vein should not be used for this purpose. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Park, Chihyun; Yun, So Jeong; Ryu, Sung Jin; Lee, Soyoung; Lee, Young-Sam; Yoon, Youngmi; Park, Sang Chul
2017-03-15
Cellular senescence irreversibly arrests growth of human diploid cells. In addition, recent studies have indicated that senescence is a multi-step evolving process related to important complex biological processes. Most studies analyzed only the genes and their functions representing each senescence phase without considering gene-level interactions and continuously perturbed genes. It is necessary to reveal the genotypic mechanism inferred by affected genes and their interaction underlying the senescence process. We suggested a novel computational approach to identify an integrative network which profiles an underlying genotypic signature from time-series gene expression data. The relatively perturbed genes were selected for each time point based on the proposed scoring measure denominated as perturbation scores. Then, the selected genes were integrated with protein-protein interactions to construct time point specific network. From these constructed networks, the conserved edges across time point were extracted for the common network and statistical test was performed to demonstrate that the network could explain the phenotypic alteration. As a result, it was confirmed that the difference of average perturbation scores of common networks at both two time points could explain the phenotypic alteration. We also performed functional enrichment on the common network and identified high association with phenotypic alteration. Remarkably, we observed that the identified cell cycle specific common network played an important role in replicative senescence as a key regulator. Heretofore, the network analysis from time series gene expression data has been focused on what topological structure was changed over time point. Conversely, we focused on the conserved structure but its context was changed in course of time and showed it was available to explain the phenotypic changes. We expect that the proposed method will help to elucidate the biological mechanism unrevealed by the existing approaches.
Hahn, Henry; Kropp, Peter; Kirschstein, Timo; Rücker, Gernot; Müller-Hilke, Brigitte
2017-01-01
During their early years at medical school, students repeatedly criticize their workload, time constraints and test associated stress. At the same time, depressiveness and anxiety among first and second year medical students are on the rise. We therefore hypothesized that test anxiety may be related to depressiveness and considered cognitive and academic performances as confounders for the former and psychosocial distress for the latter. A whole class of 200 second year students was invited to participate in the study. Anxiety as a trait, depressiveness, crystallized intelligence, verbal fluency and psychosocial distress were assessed using validated tests and questionnaires. Acute state anxiety and sympathetic stress parameters were measured in real life situations immediately before an oral and a written exam and paired tests were used to compare the individual anxieties at the various time points. Previous academic performances were self-reported, the results of the impending exams were monitored. Finally, correlations were performed to test for interrelatedness between academic performances and the various personal, cognitive and psychosocial factors. Acute test anxiety did not correlate with depressiveness nor did it correlate with previous nor impending academic performances nor any of the expected confounders on academic performance. However both, depressiveness and test anxiety strongly correlated with the perceived imbalance between efforts spent and rewards received. Moreover, anxiety as a trait not only correlated with acute state anxiety before an exam but was also significantly correlated to the feeling of over-commitment. Depressiveness during the early years of medical school seems unrelated to test anxiety and academic performance. Instead, it strongly correlated with the psychosocial distress emanating from attending medical school and points at a perceived imbalance between efforts spent and rewards received.
Hahn, Henry; Kropp, Peter; Kirschstein, Timo; Rücker, Gernot; Müller-Hilke, Brigitte
2017-01-01
Purpose During their early years at medical school, students repeatedly criticize their workload, time constraints and test associated stress. At the same time, depressiveness and anxiety among first and second year medical students are on the rise. We therefore hypothesized that test anxiety may be related to depressiveness and considered cognitive and academic performances as confounders for the former and psychosocial distress for the latter. Methods A whole class of 200 second year students was invited to participate in the study. Anxiety as a trait, depressiveness, crystallized intelligence, verbal fluency and psychosocial distress were assessed using validated tests and questionnaires. Acute state anxiety and sympathetic stress parameters were measured in real life situations immediately before an oral and a written exam and paired tests were used to compare the individual anxieties at the various time points. Previous academic performances were self-reported, the results of the impending exams were monitored. Finally, correlations were performed to test for interrelatedness between academic performances and the various personal, cognitive and psychosocial factors. Results Acute test anxiety did not correlate with depressiveness nor did it correlate with previous nor impending academic performances nor any of the expected confounders on academic performance. However both, depressiveness and test anxiety strongly correlated with the perceived imbalance between efforts spent and rewards received. Moreover, anxiety as a trait not only correlated with acute state anxiety before an exam but was also significantly correlated to the feeling of over-commitment. Conclusion Depressiveness during the early years of medical school seems unrelated to test anxiety and academic performance. Instead, it strongly correlated with the psychosocial distress emanating from attending medical school and points at a perceived imbalance between efforts spent and rewards received. PMID:28182781
Development and validation of a canine radius replica for mechanical testing of orthopedic implants.
Little, Jeffrey P; Horn, Timothy J; Marcellin-Little, Denis J; Harrysson, Ola L A; West, Harvey A
2012-01-01
To design and fabricate fiberglass-reinforced composite (FRC) replicas of a canine radius and compare their mechanical properties with those of radii from dog cadavers. Replicas based on 3 FRC formulations with 33%, 50%, or 60% short-length discontinuous fiberglass by weight (7 replicas/group) and 5 radii from large (> 30-kg) dog cadavers. Bones and FRC replicas underwent nondestructive mechanical testing including 4-point bending, axial loading, and torsion and destructive testing to failure during 4-point bending. Axial, internal and external torsional, and bending stiffnesses were calculated. Axial pullout loads for bone screws placed in the replicas and cadaveric radii were also assessed. Axial, internal and external torsional, and 4-point bending stiffnesses of FRC replicas increased significantly with increasing fiberglass content. The 4-point bending stiffness of 33% and 50% FRC replicas and axial and internal torsional stiffnesses of 33% FRC replicas were equivalent to the cadaveric bone stiffnesses. Ultimate 4-point bending loads did not differ significantly between FRC replicas and bones. Ultimate screw pullout loads did not differ significantly between 33% or 50% FRC replicas and bones. Mechanical property variability (coefficient of variation) of cadaveric radii was approximately 2 to 19 times that of FRC replicas, depending on loading protocols. Within the range of properties tested, FRC replicas had mechanical properties equivalent to and mechanical property variability less than those of radii from dog cadavers. Results indicated that FRC replicas may be a useful alternative to cadaveric bones for biomechanical testing of canine bone constructs.
Cantrell, Jennifer; Ganz, Ollie; Ilakkuvan, Vinu; Tacelosky, Michael; Kreslake, Jennifer; Moon-Howard, Joyce; Aidala, Angela; Vallone, Donna; Anesetti-Rothermel, Andrew; Kirchner, Thomas R
2015-01-01
In tobacco control and other fields, point-of-sale surveillance of the retail environment is critical for understanding industry marketing of products and informing public health practice. Innovations in mobile technology can improve existing, paper-based surveillance methods, yet few studies describe in detail how to operationalize the use of technology in public health surveillance. The aims of this paper are to share implementation strategies and lessons learned from 2 tobacco, point-of-sale surveillance projects to inform and prepare public health researchers and practitioners to implement new mobile technologies in retail point-of-sale surveillance systems. From 2011 to 2013, 2 point-of-sale surveillance pilot projects were conducted in Washington, DC, and New York, New York, to capture information about the tobacco retail environment and test the feasibility of a multimodal mobile data collection system, which included capabilities for audio or video recording data, electronic photographs, electronic location data, and a centralized back-end server and dashboard. We established a preimplementation field testing process for both projects, which involved a series of rapid and iterative tests to inform decisions and establish protocols around key components of the project. Important components of field testing included choosing a mobile phone that met project criteria, establishing an efficient workflow and accessible user interfaces for each component of the system, training and providing technical support to fieldworkers, and developing processes to integrate data from multiple sources into back-end systems that can be utilized in real-time. A well-planned implementation process is critical for successful use and performance of multimodal mobile surveillance systems. Guidelines for implementation include (1) the need to establish and allow time for an iterative testing framework for resolving technical and logistical challenges; (2) developing a streamlined workflow and user-friendly interfaces for data collection; (3) allowing for ongoing communication, feedback, and technology-related skill-building among all staff; and (4) supporting infrastructure for back-end data systems. Although mobile technologies are evolving rapidly, lessons learned from these case studies are essential for ensuring that the many benefits of new mobile systems for rapid point-of-sale surveillance are fully realized.
Ganz, Ollie; Ilakkuvan, Vinu; Tacelosky, Michael; Kreslake, Jennifer; Moon-Howard, Joyce; Aidala, Angela; Vallone, Donna; Anesetti-Rothermel, Andrew; Kirchner, Thomas R
2015-01-01
Background In tobacco control and other fields, point-of-sale surveillance of the retail environment is critical for understanding industry marketing of products and informing public health practice. Innovations in mobile technology can improve existing, paper-based surveillance methods, yet few studies describe in detail how to operationalize the use of technology in public health surveillance. Objective The aims of this paper are to share implementation strategies and lessons learned from 2 tobacco, point-of-sale surveillance projects to inform and prepare public health researchers and practitioners to implement new mobile technologies in retail point-of-sale surveillance systems. Methods From 2011 to 2013, 2 point-of-sale surveillance pilot projects were conducted in Washington, DC, and New York, New York, to capture information about the tobacco retail environment and test the feasibility of a multimodal mobile data collection system, which included capabilities for audio or video recording data, electronic photographs, electronic location data, and a centralized back-end server and dashboard. We established a preimplementation field testing process for both projects, which involved a series of rapid and iterative tests to inform decisions and establish protocols around key components of the project. Results Important components of field testing included choosing a mobile phone that met project criteria, establishing an efficient workflow and accessible user interfaces for each component of the system, training and providing technical support to fieldworkers, and developing processes to integrate data from multiple sources into back-end systems that can be utilized in real-time. Conclusions A well-planned implementation process is critical for successful use and performance of multimodal mobile surveillance systems. Guidelines for implementation include (1) the need to establish and allow time for an iterative testing framework for resolving technical and logistical challenges; (2) developing a streamlined workflow and user-friendly interfaces for data collection; (3) allowing for ongoing communication, feedback, and technology-related skill-building among all staff; and (4) supporting infrastructure for back-end data systems. Although mobile technologies are evolving rapidly, lessons learned from these case studies are essential for ensuring that the many benefits of new mobile systems for rapid point-of-sale surveillance are fully realized. PMID:27227138
NASA Astrophysics Data System (ADS)
Abahous, H.; Ronchail, J.; Sifeddine, A.; Kenny, L.; Bouchaou, L.
2017-11-01
In the context of an arid area such as Souss Massa Region, the availability of time series analysis of observed local data is vital to better characterize the regional rainfall configuration. In this paper, dataset of monthly precipitation collected from different local meteorological stations during 1932-2010, are quality controlled and analyzed to detect trend and change points. The temporal distribution of outliers shows an annual cycle and a decrease of their number since the 1980s. The results of the standard normal homogeneity test, penalized maximal t test, and Mann-Whitney-Pettit test show that 42% of the series are homogeneous. The analysis of annual precipitation in the region of Souss Massa during 1932-2010 shows wet conditions with a maximum between 1963 and 1965 followed by a decrease since 1973. The latter is identified as a statistically significant regional change point in Western High Atlas and Anti Atlas Mountains highlighting a decline in long-term average precipitation.
Stough, Con; King, Rebecca; Papafotiou, Katherine; Swann, Phillip; Ogden, Edward; Wesnes, Keith; Downey, Luke A
2012-04-01
This study investigated the acute (3-h) and 24-h post-dose cognitive effects of oral 3,4-methylenedioxymethamphetamine (MDMA), d-methamphetamine, and placebo in a within-subject double-blind laboratory-based study in order to compare the effect of these two commonly used illicit drugs on a large number of recreational drug users. Sixty-one abstinent recreational users of illicit drugs comprised the participant sample, with 33 females and 28 males, mean age 25.45 years. The three testing sessions involved oral consumption of 100 mg MDMA, 0.42 mg/kg d-methamphetamine, or a matching placebo. The drug administration was counter-balanced, double-blind, and medically supervised. Cognitive performance was assessed during drug peak (3 h) and at 24 h post-dosing time-points. Blood samples were also taken to quantify the levels of drug present at the cognitive testing time-points. Blood concentrations of both methamphetamine and MDMA at drug peak samples were consistent with levels observed in previous studies. The major findings concern poorer performance in the MDMA condition at peak concentration for the trail-making measures and an index of working memory (trend level), and more accurate performance on a choice reaction task within the methamphetamine condition. Most of the differences in performance between the MDMA, methamphetamine, and placebo treatments diminished by the 24-h testing time-point, although some performance improvements subsisted for choice reaction time for the methamphetamine condition. Further research into the acute effects of amphetamine preparations is necessary to further quantify the acute disruption of aspects of human functioning crucial to complex activities such as attention, selective memory, and psychomotor performance.
Riemannian multi-manifold modeling and clustering in brain networks
NASA Astrophysics Data System (ADS)
Slavakis, Konstantinos; Salsabilian, Shiva; Wack, David S.; Muldoon, Sarah F.; Baidoo-Williams, Henry E.; Vettel, Jean M.; Cieslak, Matthew; Grafton, Scott T.
2017-08-01
This paper introduces Riemannian multi-manifold modeling in the context of brain-network analytics: Brainnetwork time-series yield features which are modeled as points lying in or close to a union of a finite number of submanifolds within a known Riemannian manifold. Distinguishing disparate time series amounts thus to clustering multiple Riemannian submanifolds. To this end, two feature-generation schemes for brain-network time series are put forth. The first one is motivated by Granger-causality arguments and uses an auto-regressive moving average model to map low-rank linear vector subspaces, spanned by column vectors of appropriately defined observability matrices, to points into the Grassmann manifold. The second one utilizes (non-linear) dependencies among network nodes by introducing kernel-based partial correlations to generate points in the manifold of positivedefinite matrices. Based on recently developed research on clustering Riemannian submanifolds, an algorithm is provided for distinguishing time series based on their Riemannian-geometry properties. Numerical tests on time series, synthetically generated from real brain-network structural connectivity matrices, reveal that the proposed scheme outperforms classical and state-of-the-art techniques in clustering brain-network states/structures.
Sosic-Vasic, Zrinka; Hille, Katrin; Kröner, Julia; Spitzer, Manfred; Kornmeier, Jürgen
2018-01-01
Introduction: Consolidation is defined as the time necessary for memory stabilization after learning. In the present study we focused on effects of interference during the first 12 consolidation minutes after learning. Participants had to learn a set of German – Japanese word pairs in an initial learning task and a different set of German – Japanese word pairs in a subsequent interference task. The interference task started in different experimental conditions at different time points (0, 3, 6, and 9 min) after the learning task and was followed by subsequent cued recall tests. In a control experiment the interference periods were replaced by rest periods without any interference. Results: The interference task decreased memory performance by up to 20%, with negative effects at all interference time points and large variability between participants concerning both the time point and the size of maximal interference. Further, fast learners seem to be more affected by interference than slow learners. Discussion: Our results indicate that the first 12 min after learning are highly important for memory consolidation, without a general pattern concerning the precise time point of maximal interference across individuals. This finding raises doubts about the generalized learning recipes and calls for individuality of learning schedules. PMID:29503621
Fukui, Atsuko; Fujii, Ryuta; Yonezawa, Yorinobu; Sunada, Hisakazu
2006-08-01
In the pharmaceutical preparation of a controlled release drug, it is very important and necessary to understand the entire release properties. As the first step, the dissolution test under various conditions is selected for the in vitro test, and usually the results are analyzed following Drug Approval and Licensing Procedures. In this test, 3 time points for each release ratio, such as 0.2-0.4, 0.4-0.6, and over 0.7, respectively, should be selected in advance. These are analyzed as to whether their values are inside or outside the prescribed aims at each time point. This method is very simple and useful but the details of the release properties can not be clarified or confirmed. The validity of the dissolution test in analysis using a combination of the square-root time law and cube-root law equations to understand all the drug release properties was confirmed by comparing the simulated value with that measured in the previous papers. Dissolution tests under various conditions affecting drug release properties in the human body were then examined, and the results were analyzed by both methods to identify their strengths and weaknesses. Hereafter, the control of pharmaceutical preparation, the manufacturing process, and understanding the drug release properties will be more efficient. It is considered that analysis using the combination of the square-root time law and cube-root law equations is very useful and efficient. The accuracy of predicting drug release properties in the human body was improved and clarified.
Mugambi, Melissa Latigo; Deo, Sarang; Kekitiinwa, Adeodata; Kiyaga, Charles; Singer, Mendel E.
2013-01-01
Background There is scant evidence on the association between diagnosis delays and the receipt of test results in HIV Early Infant Diagnosis (EID) programs. We determine the association between diagnosis delays and other health care system and patient factors on result receipt. Methods We reviewed 703 infant HIV test records for tests performed between January 2008 and February 2009 at a regional referral hospital and level four health center in Uganda. The main outcome was caregiver receipt of the test result. The primary study variable was turnaround time (time between sample collection and result availability at the health facility). Additional variables included clinic entry point, infant age at sample collection, reported HIV status and receipt of antiretroviral prophylaxis for prevention of mother-to-child transmission. We conducted a pooled analysis in addition to separate analyses for each facility. We estimated the relative risk of result receipt using modified Poisson regression with robust standard errors. Results Overall, the median result turnaround time, was 38 days. 59% of caregivers received infant test results. Caregivers were less likely to receive results at turnaround times greater than 49 days compared to 28 days or fewer (ARR = 0.83; 95% CI = 0.70–0.98). Caregivers were more likely to receive results at the PMTCT clinic (ARR = 1.81; 95% CI = 1.40–2.33) and less likely at the pediatric ward (ARR = 0.54; 95% CI = 0.37–0.81) compared to the immunization clinic. At the level four health center, result receipt was half as likely among infants older than 9 months compared to 3 months and younger (ARR= 0.47; 95% CI = 0.25–0.93). Conclusion In this study setting, we find evidence that longer turnaround times, clinic entry point and age at sample collection may be associated with receipt of infant HIV test results. PMID:24282502
van Eijk, Ruben PA; Eijkemans, Marinus JC; Rizopoulos, Dimitris
2018-01-01
Objective Amyotrophic lateral sclerosis (ALS) clinical trials based on single end points only partially capture the full treatment effect when both function and mortality are affected, and may falsely dismiss efficacious drugs as futile. We aimed to investigate the statistical properties of several strategies for the simultaneous analysis of function and mortality in ALS clinical trials. Methods Based on the Pooled Resource Open-Access ALS Clinical Trials (PRO-ACT) database, we simulated longitudinal patterns of functional decline, defined by the revised amyotrophic lateral sclerosis functional rating scale (ALSFRS-R) and conditional survival time. Different treatment scenarios with varying effect sizes were simulated with follow-up ranging from 12 to 18 months. We considered the following analytical strategies: 1) Cox model; 2) linear mixed effects (LME) model; 3) omnibus test based on Cox and LME models; 4) composite time-to-6-point decrease or death; 5) combined assessment of function and survival (CAFS); and 6) test based on joint modeling framework. For each analytical strategy, we calculated the empirical power and sample size. Results Both Cox and LME models have increased false-negative rates when treatment exclusively affects either function or survival. The joint model has superior power compared to other strategies. The composite end point increases false-negative rates among all treatment scenarios. To detect a 15% reduction in ALSFRS-R decline and 34% decline in hazard with 80% power after 18 months, the Cox model requires 524 patients, the LME model 794 patients, the omnibus test 526 patients, the composite end point 1,274 patients, the CAFS 576 patients and the joint model 464 patients. Conclusion Joint models have superior statistical power to analyze simultaneous effects on survival and function and may circumvent pitfalls encountered by other end points. Optimizing trial end points is essential, as selecting suboptimal outcomes may disguise important treatment clues. PMID:29593436
Zullo, Marzio Angelo; Plotti, Francesco; Calcagno, Marco; Marullo, Elettra; Palaia, Innocenza; Bellati, Filippo; Basile, Stefano; Muzii, Ludovico; Angioli, Roberto; Panici, Pierluigi Benedetti
2007-05-01
To compare tension-free vaginal tape (TVT) and trans-obturator suburethral tape from inside to outside (TVT-O) for surgical treatment of stress urinary incontinence (SUI) for complications (primary end point) and success rate (secondary end point). Seventy-two consecutive patients, with a mean age of 53.2 yr (range: 38-69 yr) and affected by SUI, were included in this randomised controlled trial. After preoperative assessment, patients were randomly allocated to the TVT or TVT-O procedure. Operative time, perioperative complications, and hospital stay were prospectively recorded. Cure of SUI was defined as no leakage of urine during the stress test at urodynamic testing at the 12-mo evaluation. The Wilcoxon signed rank sum test, Mann-Whitney U test, McNemar test, and Fisher exact test were used to verify statistical significance, set at p<0.05. All patients were evaluable at the 12-mo follow-up. The characteristics of patients were well balanced between groups after randomisation. The mean operative time was significantly shorter in the TVT-O group. Perioperative complications were significantly more common after the retropubic approach (5% and 27% in TVT-O and TVT groups, respectively, p<0.04). The groups did not differ significantly in intraoperative blood loss, hospital stays, and time to return to normal activities. Sixty-five patients (90%) were successfully treated for SUI 12 mo after the operation (89% and 91% for TVT-O and TVT groups, respectively). Both techniques appear to be equally effective in the surgical treatment of SUI. However, TVT-O had a shorter operative time and lower overall perioperative complication rate.
On-Line, Self-Learning, Predictive Tool for Determining Payload Thermal Response
NASA Technical Reports Server (NTRS)
Jen, Chian-Li; Tilwick, Leon
2000-01-01
This paper will present the results of a joint ManTech / Goddard R&D effort, currently under way, to develop and test a computer based, on-line, predictive simulation model for use by facility operators to predict the thermal response of a payload during thermal vacuum testing. Thermal response was identified as an area that could benefit from the algorithms developed by Dr. Jeri for complex computer simulations. Most thermal vacuum test setups are unique since no two payloads have the same thermal properties. This requires that the operators depend on their past experiences to conduct the test which requires time for them to learn how the payload responds while at the same time limiting any risk of exceeding hot or cold temperature limits. The predictive tool being developed is intended to be used with the new Thermal Vacuum Data System (TVDS) developed at Goddard for the Thermal Vacuum Test Operations group. This model can learn the thermal response of the payload by reading a few data points from the TVDS, accepting the payload's current temperature as the initial condition for prediction. The model can then be used as a predictive tool to estimate the future payload temperatures according to a predetermined shroud temperature profile. If the error of prediction is too big, the model can be asked to re-learn the new situation on-line in real-time and give a new prediction. Based on some preliminary tests, we feel this predictive model can forecast the payload temperature of the entire test cycle within 5 degrees Celsius after it has learned 3 times during the beginning of the test. The tool will allow the operator to play "what-if' experiments to decide what is his best shroud temperature set-point control strategy. This tool will save money by minimizing guess work and optimizing transitions as well as making the testing process safer and easier to conduct.
Benchmark Calibration Tests Completed for Stirling Convertor Heater Head Life Assessment
NASA Technical Reports Server (NTRS)
Krause, David L.; Halford, Gary R.; Bowman, Randy R.
2005-01-01
A major phase of benchmark testing has been completed at the NASA Glenn Research Center (http://www.nasa.gov/glenn/), where a critical component of the Stirling Radioisotope Generator (SRG) is undergoing extensive experimentation to aid the development of an analytical life-prediction methodology. Two special-purpose test rigs subjected SRG heater-head pressure-vessel test articles to accelerated creep conditions, using the standard design temperatures to stay within the wall material s operating creep-response regime, but increasing wall stresses up to 7 times over the design point. This resulted in well-controlled "ballooning" of the heater-head hot end. The test plan was developed to provide critical input to analytical parameters in a reasonable period of time.
Image Capture and Display Based on Embedded Linux
NASA Astrophysics Data System (ADS)
Weigong, Zhang; Suran, Di; Yongxiang, Zhang; Liming, Li
For the requirement of building a highly reliable communication system, SpaceWire was selected in the integrated electronic system. There was a need to test the performance of SpaceWire. As part of the testing work, the goal of this paper is to transmit image data from CMOS camera through SpaceWire and display real-time images on the graphical user interface with Qt in the embedded development platform of Linux & ARM. A point-to-point mode of transmission was chosen; the running result showed the two communication ends basically reach a consensus picture in succession. It suggests that the SpaceWire can transmit the data reliably.
Inflation, quintessence, and the origin of mass
NASA Astrophysics Data System (ADS)
Wetterich, C.
2015-08-01
In a unified picture both inflation and present dynamical dark energy arise from the same scalar field. The history of the Universe describes a crossover from a scale invariant "past fixed point" where all particles are massless, to a "future fixed point" for which spontaneous breaking of the exact scale symmetry generates the particle masses. The cosmological solution can be extrapolated to the infinite past in physical time - the universe has no beginning. This is seen most easily in a frame where particle masses and the Planck mass are field-dependent and increase with time. In this "freeze frame" the Universe shrinks and heats up during radiation and matter domination. In the equivalent, but singular Einstein frame cosmic history finds the familiar big bang description. The vicinity of the past fixed point corresponds to inflation. It ends at a first stage of the crossover. A simple model with no more free parameters than ΛCDM predicts for the primordial fluctuations a relation between the tensor amplitude r and the spectral index n, r = 8.19 (1 - n) - 0.137. The crossover is completed by a second stage where the beyond-standard-model sector undergoes the transition to the future fixed point. The resulting increase of neutrino masses stops a cosmological scaling solution, relating the present dark energy density to the present neutrino mass. At present our simple model seems compatible with all observational tests. We discuss how the fixed points can be rooted within quantum gravity in a crossover between ultraviolet and infrared fixed points. Then quantum properties of gravity could be tested both by very early and late cosmology.
Luo, Xiaoteng; Hsing, I-Ming
2009-10-01
Nucleic acid based analysis provides accurate differentiation among closely affiliated species and this species- and sequence-specific detection technique would be particularly useful for point-of-care (POC) testing for prevention and early detection of highly infectious and damaging diseases. Electrochemical (EC) detection and polymerase chain reaction (PCR) are two indispensable steps, in our view, in a nucleic acid based point-of-care testing device as the former, in comparison with the fluorescence counterpart, provides inherent advantages of detection sensitivity, device miniaturization and operation simplicity, and the latter offers an effective way to boost the amount of targets to a detectable quantity. In this mini-review, we will highlight some of the interesting investigations using the combined EC detection and PCR amplification approaches for end-point detection and real-time monitoring. The promise of current approaches and the direction for future investigations will be discussed. It would be our view that the synergistic effect of the combined EC-PCR steps in a portable device provides a promising detection technology platform that will be ready for point-of-care applications in the near future.
Marques, Alda; Almeida, Sara; Carvalho, Joana; Cruz, Joana; Oliveira, Ana; Jácome, Cristina
2016-12-01
To assess the reliability, validity, and ability to identify fall status of the Balance Evaluation Systems Test (BESTest), Mini-BESTest, and Brief-BESTest, compared with the Berg Balance Scale (BBS), in older people living in the community. Cross-sectional. Community centers. Older adults (N=122; mean age ± SD, 76±9y). Not applicable. Participants reported on falls history in the preceding year and completed the Activities-Specific Balance Confidence (ABC) Scale. The BBS, BESTest, and the Five Times Sit-To-Stand Test were administered. Interrater (2 physiotherapists) and test-retest relative (48-72h) and absolute reliabilities were explored with the intraclass correlation coefficient (ICC) equation (2,1) and the Bland and Altman method. Minimal detectable changes at the 95% confidence level (MDC 95 ) were established. Validity was assessed by correlating the balance tests with each other and with the ABC Scale (Spearman correlation coefficients-ρ). Receiver operating characteristics assessed the ability of each balance test to differentiate between people with and without a history of falls. All balance tests presented good to excellent interrater (ICC=.71-.93) and test-retest (ICC=.50-.82) relative reliability, with no evidence of bias. MDC 95 values were 4.6, 9, 3.8, and 4.1 points for the BBS, BESTest, Mini-BESTest, and Brief-BESTest, respectively. All tests were significantly correlated with each other (ρ=.83-.96) and with the ABC Scale (ρ=.46-.61). Acceptable ability to identify fall status (areas under the curve, .71-.78) was found for all tests. Cutoff points were 48.5, 82, 19.5, and 12.5 points for the BBS, BESTest, Mini-BESTest, and Brief-BESTest, respectively. All balance tests are reliable, valid, and able to identify fall status in older people living in the community. Therefore, the choice of which test to use will depend on the level of balance impairment, purpose, and time availability. Copyright © 2016. Published by Elsevier Inc.
Predicting the time of conversion to MCI in the elderly: role of verbal expression and learning.
Oulhaj, Abderrahim; Wilcock, Gordon K; Smith, A David; de Jager, Celeste A
2009-11-03
Increasing awareness that minimal or mild cognitive impairment (MCI) in the elderly may be a precursor of dementia has led to an increase in the number of people attending memory clinics. We aimed to develop a way of predicting the period of time before cognitive impairment occurs in community-dwelling elderly. The method is illustrated by the use of simple tests of different cognitive domains. A cohort of 241 normal elderly volunteers was followed for up to 20 years with regular assessments of cognitive abilities using the Cambridge Cognitive Examination (CAMCOG); 91 participants developed MCI. We used interval-censored survival analysis statistical methods to model which baseline cognitive tests best predicted the time to convert to MCI. Out of several baseline variables, only age and CAMCOG subscores for expression and learning/memory were predictors of the time to conversion. The time to conversion was 14% shorter for each 5 years of age, 17% shorter for each point lower in the expression score, and 15% shorter for each point lower in the learning score. We present in tabular form the probability of converting to MCI over intervals between 2 and 10 years for different combinations of expression and learning scores. In apparently normal elderly people, subtle measurable cognitive deficits that occur within the normal range on standard testing protocols reliably predict the time to clinically relevant cognitive impairment long before clinical symptoms are reported.
Coquart, Jérémy B; Mucci, Patrick; L'hermette, Maxime; Chamari, Karim; Tourny, Claire; Garcin, Murielle
2017-03-01
The twofold aim of the study was to: 1) compare the gas exchange threshold (GET), the first oxyhemoglobin inflection point ([O2Hb]-T), and perceptual threshold as determined during an incremental exercise test, and 2) investigate the link between each threshold and time-to-exhaustion during heavy intensity exercise. Fourteen competitive cyclists performed an incremental exercise test to exhaustion on a cycloergometer to determine the different thresholds and peak workload (Wpeak). The participants then performed a sub-maximal constant workload test (90% Wpeak) to exhaustion to determine time-to-exhaustion. The thresholds were identified from: 1) the first breakpoint in the oxygen uptake vs. carbon dioxide output curve (GET), 2) the [O2Hb]-T, and 3) a rating of 13 in perceived exertion (perceptual threshold: RPE13-T). Oxygen uptake at the different thresholds was not significantly different (P>0.05). Moreover, GET and [O2Hb]-T were significantly correlated: 1) to each other (r≥0.79; P≤0.001), and 2) to time-to-exhaustion (r=0.81 and r=0.72, respectively; P<0.01). RPE13-T, however, was not significantly correlated with the time-to-exhaustion (P=0.148). The anaerobic threshold as identified from GET was concomitant to [O2Hb]-T. Both thresholds were correlated to time-to-exhaustion, and could therefore be used as a performance index in middle-duration events.
A quantitative dynamic systems model of health-related quality of life among older adults
Roppolo, Mattia; Kunnen, E Saskia; van Geert, Paul L; Mulasso, Anna; Rabaglietti, Emanuela
2015-01-01
Health-related quality of life (HRQOL) is a person-centered concept. The analysis of HRQOL is highly relevant in the aged population, which is generally suffering from health decline. Starting from a conceptual dynamic systems model that describes the development of HRQOL in individuals over time, this study aims to develop and test a quantitative dynamic systems model, in order to reveal the possible dynamic trends of HRQOL among older adults. The model is tested in different ways: first, with a calibration procedure to test whether the model produces theoretically plausible results, and second, with a preliminary validation procedure using empirical data of 194 older adults. This first validation tested the prediction that given a particular starting point (first empirical data point), the model will generate dynamic trajectories that lead to the observed endpoint (second empirical data point). The analyses reveal that the quantitative model produces theoretically plausible trajectories, thus providing support for the calibration procedure. Furthermore, the analyses of validation show a good fit between empirical and simulated data. In fact, no differences were found in the comparison between empirical and simulated final data for the same subgroup of participants, whereas the comparison between different subgroups of people resulted in significant differences. These data provide an initial basis of evidence for the dynamic nature of HRQOL during the aging process. Therefore, these data may give new theoretical and applied insights into the study of HRQOL and its development with time in the aging population. PMID:26604722
Experimental and numerical analysis of metal leaching from fly ash-amended highway bases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cetin, Bora; Aydilek, Ahmet H., E-mail: aydilek@umd.edu; Li, Lin
2012-05-15
Highlights: Black-Right-Pointing-Pointer This study is the evaluation of leaching potential of fly ash-lime mixed soils. Black-Right-Pointing-Pointer This objective is met with experimental and numerical analysis. Black-Right-Pointing-Pointer Zn leaching decreases with increase in fly ash content while Ba, B, Cu increases. Black-Right-Pointing-Pointer Decrease in lime content promoted leaching of Ba, B and Cu while Zn increases. Black-Right-Pointing-Pointer Numerical analysis predicted lower field metal concentrations. - Abstract: A study was conducted to evaluate the leaching potential of unpaved road materials (URM) mixed with lime activated high carbon fly ashes and to evaluate groundwater impacts of barium, boron, copper, and zinc leaching. Thismore » objective was met by a combination of batch water leach tests, column leach tests, and computer modeling. The laboratory tests were conducted on soil alone, fly ash alone, and URM-fly ash-lime kiln dust mixtures. The results indicated that an increase in fly ash and lime content has significant effects on leaching behavior of heavy metals from URM-fly ash mixture. An increase in fly ash content and a decrease in lime content promoted leaching of Ba, B and Cu whereas Zn leaching was primarily affected by the fly ash content. Numerically predicted field metal concentrations were significantly lower than the peak metal concentrations obtained in laboratory column leach tests, and field concentrations decreased with time and distance due to dispersion in soil vadose zone.« less
The liquid wood heat flow and material properties as a function of temperature
NASA Astrophysics Data System (ADS)
Mazurchevici, Simona; Quadrini, Fabrizio; Nedelcu, Dumitru
2018-03-01
There are three types of ‘liquid wood’, Arbofill, Arboblend and Arboform and will replace plastics materials in the near future taking into account the biodegradability and higher properties versus common used plastics materials. In order to get more information about the materials properties of ‘liquid wood’ the granules and samples obtained by injection molding were studied using Differential Scanning Calorimetry (DSC) and Dynamic Mechanical Analysis (DMA) for Arboform L,V3 Nature-‘liquid wood’ (A-LW) and Arboform L, V3 Nature reinforced with Aramid Fibers (A-LWAF).In case of A-LW granule studied, the DSC analysis presents that at 97 °C appears an endoderm peak which represents the crystallization of the material, at 175 °C the exoderm peak which means the melting point of the material. After the tested granule cooling period of time this one was tested again and the endoderm peak disappears, which means that crystallization of material disappeared. The melting point of the second test decreases slightly at 174.6 °C. Also, the new test shows that at 61.7 °C the glass transition temperature appears and the melting point slightly decreases. In case of A-LW samples the DSC analyses shows that the melting point increased by 2.77 °C compared to the melting point of Arboform granule. The material behavior is more or less the same without the crystallization area.
NASA Technical Reports Server (NTRS)
Zimmerli, Gregory A.; Goldburg, Walter I.
2002-01-01
A novel technique for characterizing turbulent flows was developed and tested at the NASA Glenn Research Center. The work is being done in collaboration with the University of Pittsburgh, through a grant from the NASA Microgravity Fluid Physics Program. The technique we are using, Homodyne Correlation Spectroscopy (HCS), is a laser-light-scattering technique that measures the Doppler frequency shift of light scattered from microscopic particles in the fluid flow. Whereas Laser Doppler Velocimetry gives a local (single-point) measurement of the fluid velocity, the HCS technique measures correlations between fluid velocities at two separate points in the flow at the same instant of time. Velocity correlations in the flow field are of fundamental interest to turbulence researchers and are of practical importance in many engineering applications, such as aeronautics.
Lacerda, Vánia A; Pereira, Leandro O; Hirata JUNIOR, Raphael; Perez, Cesar R
2015-12-01
To evaluate the effectiveness of disinfection/sterilization methods and their effects on polishing capacity, micomorphology, and composition of two different composite fiishing and polishing instruments. Two brands of finishing and polishing instruments (Jiffy and Optimize), were analyzed. For the antimicrobial test, 60 points (30 of each brand) were used for polishing composite restorations and submitted to three different groups of disinfection/sterilization methods: none (control), autoclaving, and immersion in peracetic acid for 60 minutes. The in vitro tests were performed to evaluate the polishing performance on resin composite disks (Amelogen) using a 3D scanner (Talyscan) and to evaluate the effects on the points' surface composition (XRF) and micromorphology (MEV) after completing a polishing and sterilizing routine five times. Both sterilization/disinfection methods were efficient against oral cultivable organisms and no deleterious modification was observed to point surface.
Adaptive Neuro-Fuzzy Modeling of UH-60A Pilot Vibration
NASA Technical Reports Server (NTRS)
Kottapalli, Sesi; Malki, Heidar A.; Langari, Reza
2003-01-01
Adaptive neuro-fuzzy relationships have been developed to model the UH-60A Black Hawk pilot floor vertical vibration. A 200 point database that approximates the entire UH-60A helicopter flight envelope is used for training and testing purposes. The NASA/Army Airloads Program flight test database was the source of the 200 point database. The present study is conducted in two parts. The first part involves level flight conditions and the second part involves the entire (200 point) database including maneuver conditions. The results show that a neuro-fuzzy model can successfully predict the pilot vibration. Also, it is found that the training phase of this neuro-fuzzy model takes only two or three iterations to converge for most cases. Thus, the proposed approach produces a potentially viable model for real-time implementation.
De Francesco, Vincenzo; Zullo, Angelo; Giorgio, Floriana; Saracino, Ilaria; Zaccaro, Cristina; Hassan, Cesare; Ierardi, Enzo; Di Leo, Alfredo; Fiorini, Giulia; Castelli, Valentina; Lo Re, Giovanna; Vaira, Dino
2014-03-01
Primary clarithromycin resistance is the main factor affecting the efficacy of Helicobacter pylori therapy. This study aimed: (i) to assess the concordance between phenotypic (culture) and genotypic (real-time PCR) tests in resistant strains; (ii) to search, in the case of disagreement between the methods, for point mutations other than those reported as the most frequent in Europe; and (iii) to compare the MICs associated with the single point mutations. In order to perform real-time PCR, we retrieved biopsies from patients in whom H. pylori infection was successful diagnosed by bacterial culture and clarithromycin resistance was assessed using the Etest. Only patients who had never been previously treated, and with H. pylori strains that were either resistant exclusively to clarithromycin or without any resistance, were included. Biopsies from 82 infected patients were analysed, including 42 strains that were clarithromycin resistant and 40 that were clarithromycin susceptible on culture. On genotypic analysis, at least one of the three most frequently reported point mutations (A2142C, A2142G and A2143G) was detected in only 23 cases (54.8%), with a concordance between the two methods of 0.67. Novel point mutations (A2115G, G2141A and A2144T) were detected in a further 14 out of 19 discordant cases, increasing the resistance detection rate of PCR to 88% (P<0.001; odds ratio 6.1, 95% confidence interval 2-18.6) and the concordance to 0.81. No significant differences in MIC values among different point mutations were observed. This study suggests that: (i) the prevalence of the usually reported point mutations may be decreasing, with a concomitant emergence of new mutations; (ii) PCR-based methods should search for at least six point mutations to achieve good accuracy in detecting clarithromycin resistance; and (iii) none of the tested point mutations is associated with significantly higher MIC values than the others.
Automatic system testing of a decision support system for insulin dosing using Google Android.
Spat, Stephan; Höll, Bernhard; Petritsch, Georg; Schaupp, Lukas; Beck, Peter; Pieber, Thomas R
2013-01-01
Hyperglycaemia in hospitalized patients is a common and costly health care problem. The GlucoTab system is a mobile workflow and decision support system, aiming to facilitate efficient and safe glycemic control of non-critically ill patients. Being a medical device, the GlucoTab requires extensive and reproducible testing. A framework for high-volume, reproducible and automated system testing of the GlucoTab system was set up applying several Open Source tools for test automation and system time handling. The REACTION insulin titration protocol was investigated in a paper-based clinical trial (PBCT). In order to validate the GlucoTab system, data from this trial was used for simulation and system tests. In total, 1190 decision support action points were identified and simulated. Four data points (0.3%) resulted in a GlucoTab system error caused by a defective implementation. In 144 data points (12.1%), calculation errors of physicians and nurses in the PBCT were detected. The test framework was able to verify manual calculation of insulin doses and detect relatively many user errors and workflow anomalies in the PBCT data. This shows the high potential of the electronic decision support application to improve safety of implementation of an insulin titration protocol and workflow management system in clinical wards.
Testing single point incremental forming moulds for rotomoulding operations
NASA Astrophysics Data System (ADS)
Afonso, Daniel; de Sousa, Ricardo Alves; Torcato, Ricardo
2017-10-01
Low pressure polymer processes as thermoforming or rotational moulding use much simpler moulds than high pressure processes like injection. However, despite the low forces involved in the process, moulds manufacturing for these applications is still a very material, energy and time consuming operation. Particularly in rotational moulding there is no standard for the mould manufacture and very different techniques are applicable. The goal of this research is to develop and validate a method for manufacturing plastically formed sheet metal moulds by single point incremental forming (SPIF) for rotomoulding and rotocasting operations. A Stewart platform based SPIF machine allow the forming of thick metal sheets, granting the required structural stiffness for the mould surface, and keeping a short manufacture lead time and low thermal inertia. The experimental work involves the proposal of a hollow part, design and fabrication of a sheet metal mould using dieless incremental forming techniques and testing its operation in the production of prototype parts.
Kim, Miso; Park, Kwan-Dong
2017-01-01
We have developed a suite of real-time precise point positioning programs to process GPS pseudorange observables, and validated their performance through static and kinematic positioning tests. To correct inaccurate broadcast orbits and clocks, and account for signal delays occurring from the ionosphere and troposphere, we applied State Space Representation (SSR) error corrections provided by the Seoul Broadcasting System (SBS) in South Korea. Site displacements due to solid earth tide loading are also considered for the purpose of improving the positioning accuracy, particularly in the height direction. When the developed algorithm was tested under static positioning, Kalman-filtered solutions produced a root-mean-square error (RMSE) of 0.32 and 0.40 m in the horizontal and vertical directions, respectively. For the moving platform, the RMSE was found to be 0.53 and 0.69 m in the horizontal and vertical directions. PMID:28598403
NASA Technical Reports Server (NTRS)
Miles, J. H.; Wasserbauer, C. A.; Krejsa, E. A.
1983-01-01
Pressure temperature cross spectra are necessary in predicting noise propagation in regions of velocity gradients downstream of combustors if the effect of convective entropy disturbances is included. Pressure temperature cross spectra and coherences were measured at spatially separated points in a combustion rig fueled with hydrogen. Temperature-temperature and pressure-pressure cross spectra and coherences between the spatially separated points as well as temperature and pressure autospectra were measured. These test results were compared with previous results obtained in the same combustion rig using Jet A fuel in order to investigate their dependence on the type of combustion process. The phase relationships are not consistent with a simple source model that assumes that pressure and temperature are in phase at a point in the combustor and at all other points downstream are related to one another by only a time delay due to convection of temperature disturbances. Thus these test results indicate that a more complex model of the source is required.
2012-11-01
within the fronto-striatal regions (e.g., processing speed) [5–7] than cortical dementias such as Alzheimer disease. As such, traditional cognitive...Part A, PASAT, and HVLT-R Learning avoids the requirement of having the color stimuli of the Stroop tests and replaces it with the Trail Making Test...assessment time points to avoid practice effect problems; however, this would require those who administer the tests to be trained on a wider range of
Point-of-care diagnostics: market trends and growth drivers.
Rajan, Aruna; Glorikian, Harry
2009-01-01
There is a significant demand for in vitro diagnostic (IVD) testing to move closer to the patient point-of-care diagnostics [POC]), whether in the hospital, physician's office, rapid clinic or the home, effectively cutting time to results and helping patients make better informed decisions about their health. To analyze the point-of-care market and its trends and growth drivers. In 2007, POC made up 30% of the IVD market and is expected to grow at 9% a year. Although the overall POC market is expected to grow steadily, infectious POC is now the most attractive segment. Availability of rapid random access molecular diagnostic system for critical care infectious diseases such as MRSA and sepsis in the near future is likely to be a significant driver of infectious POC post 2012. Owing to the extraordinary increase in the cost of care, healthcare delivery is moving to increasingly decentralized settings such as rapid clinics and the home, driven by point-of-care diagnostics that provide accurate and directional results. We are evolving from the analog testing world to the digital testing world, where diagnosis is exact and therapy can be administered and be predictably effective.
Beam-Switch Transient Effects in the RF Path of the ICAPA Receive Phased Array Antenna
NASA Technical Reports Server (NTRS)
Sands, O. Scott
2003-01-01
When the beam of a Phased Array Antenna (PAA) is switched from one pointing direction to another, transient effects in the RF path of the antenna are observed. Testing described in the report has revealed implementation-specific transient effects in the RF channel that are associated with digital clocking pulses that occur with transfer of data from the Beam Steering Controller (BSC) to the digital electronics of the PAA under test. The testing described here provides an initial assessment of the beam-switch phenomena by digitally acquiring time series of the RF communications channel, under CW excitation, during the period of time that the beam switch transient occurs. Effects are analyzed using time-frequency distributions and instantaneous frequency estimation techniques. The results of tests conducted with CW excitation supports further Bit-Error-Rate (BER) testing of the PAA communication channel.
Maggi, Federico; Bosco, Domenico; Galetto, Luciana; Palmano, Sabrina; Marzachì, Cristina
2017-01-01
Analyses of space-time statistical features of a flavescence dorée (FD) epidemic in Vitis vinifera plants are presented. FD spread was surveyed from 2011 to 2015 in a vineyard of 17,500 m2 surface area in the Piemonte region, Italy; count and position of symptomatic plants were used to test the hypothesis of epidemic Complete Spatial Randomness and isotropicity in the space-time static (year-by-year) point pattern measure. Space-time dynamic (year-to-year) point pattern analyses were applied to newly infected and recovered plants to highlight statistics of FD progression and regression over time. Results highlighted point patterns ranging from disperse (at small scales) to aggregated (at large scales) over the years, suggesting that the FD epidemic is characterized by multiscale properties that may depend on infection incidence, vector population, and flight behavior. Dynamic analyses showed moderate preferential progression and regression along rows. Nearly uniform distributions of direction and negative exponential distributions of distance of newly symptomatic and recovered plants relative to existing symptomatic plants highlighted features of vector mobility similar to Brownian motion. These evidences indicate that space-time epidemics modeling should include environmental setting (e.g., vineyard geometry and topography) to capture anisotropicity as well as statistical features of vector flight behavior, plant recovery and susceptibility, and plant mortality. PMID:28111581
Results of Performance Tests Performed on the John Watts WW Casing Connection on 7" Pipe
DOE Office of Scientific and Technical Information (OSTI.GOV)
John D. Watts
2000-02-01
Stress Engineering Services (SES) was contracted by Mr. John Watts to test his ''WW'' threaded connection developed for oilfield oil and gas service. This work was a continuation of testing performed by SES as reported in August of 1999. The connection design tested was identified as ''WW''. The samples were all integral (no coupled connections) and contained a wedge thread form with 90{sup o} flank angles relative to the pipe centerline. The wedge thread form is a variable width thread that primarily engages on the flanks. This thread form provides very high torque capacity and good stabbing ability and makeup.more » The test procedure selected for one of the samples was the newly written ISO 13679 procedure for full scale testing of casing and tubing connections, which is currently going through the ISO acceptance process. The ISO procedure requires a variety of tests that includes makeup/breakout testing, internal gas sealability/external water sealability testing with axial tension, axial compression, bending, internal gas thermal cycle tests and limit load (failure) tests. This test procedure was performed with one sample. Four samples were tested to failure. Table 1 contains a summary of the tasks performed by SES. The project started with the delivery of test samples by Mr. Watts. Pipe from the previous round of tests was used for the new samples. Figure 1 shows the structural and sealing results relative to the pipe body. Sample 1 was used to determine the torque capacity of the connection. Torque was applied to the capacity of SES's equipment which was 28,424 ft-lbs. From this, an initial recommended torque range of 7,200 to 8,800 ft-lbs. was selected. The sample was disassembled and while there was no galling observed in the threads, the end of the pin had collapsed inward. Sample 2 received three makeups. Breakouts 1 and 2 also had collapsing of the pin end, with no thread galling. From these make/breaks, it was decided to reduce the amount of lubricant applied to the connection by applying it to the box or pin only and reducing the amount applied. Samples 3 and 4 received one makeup only. Sample 5 initially received two make/breaks to test for galling resistance before final makeup, No galling was observed. Later, three additional make/breaks were performed with no pin end collapse and galling over 1/2 a thread occurring on one of the breakouts. During the make/break tests, the stabbing and hand tight makeup of the WW connection was found to be very easy and trouble free. There was no tendency to crossthread, even when stabbed at an angle, and it screwed together very smoothly up to hand tight. During power tight makeup, there was no heat generated in the box (as checked by hand contact) and no jerkiness associated with any of the makeups or breakouts. Sample 2 was tested in pure compression. The maximum load obtained was 1,051 kips and the connection was beginning to significantly deform as the sample buckled. Actual pipe yield was 1,226 kips. Sample 3 was capped-end pressure tested to failure. The capped-end yield pressure of the pipe was 16,572 psi and the sample began to leak at 12,000 psi. Sample 4 was tested in pure tension. The maximum load obtained was 978 kips and the connection failed by fracture at the pin critical section. Actual pipe yield was 1,226 kips. Sample 5 was tested in combined tension/compression and internal gas pressure. The sample was assembled, setup and tested four times. The first time was with a torque of 7,298 ft-lbs and the connection leaked halfway to ISO Load Point 2 with loads of 693 kips and 4,312 psi. The second time the torque was increased to 14,488 ft-lbs and a leak occurred at 849 kips and 9,400 psi, which was ISO Load Point 2. The third time the makeup torque was again increased, to 20,456 ft-lbs, and a leak occurred at 716 kips and 11,342 psi, ISO Load Point 4. The fourth test was with the same torque as before, 20,617 ft-lbs, and the connection successfully tested up to load step 56, ISO Load Point 6 (second round) before leaking at 354 kips and 11,876 psi. At this point, time and funds prevented additional testing to be performed.« less
ERIC Educational Resources Information Center
Powell, Lesley; Cheshire, Anna
2008-01-01
The purpose of this study is to adapt, deliver, and pilot test the Self-discovery Programme (SDP) for teachers in mainstream school. The study used a pre-test post-test design. Quantitative data were collected by self-administered questionnaires given to teachers at two points in time: baseline (immediately pre-SDP) and immediately post-SDP.…
Weidle, Paul J; Lecher, Shirley; Botts, Linda W; Jones, LaDawna; Spach, David H; Alvarez, Jorge; Jones, Rhondette; Thomas, Vasavi
2014-01-01
To test the feasibility of offering rapid point-of-care human immunodeficiency virus (HIV) testing at community pharmacies and retail clinics. Pilot program to determine how to implement confidential HIV testing services in community pharmacies and retail clinics. 21 community pharmacies and retail clinics serving urban and rural patients in the United States, from August 2011 to July 2013. 106 community pharmacy and retail clinic staff members. A model was developed to implement confidential HIV counseling and testing services using community pharmacy and retail clinic staff as certified testing providers, or through collaborations with organizations that provide HIV testing. Training materials were developed and sites selected that serve patients from urban and rural areas to pilot test the model. Each site established a relationship with its local health department for HIV testing policies, developed referral lists for confirmatory HIV testing/care, secured a CLIA Certificate of Waiver, and advertised the service. Staff were trained to perform a rapid point-of-care HIV test on oral fluid, and provide patients with confidential test results and information on HIV. Patients with a preliminary positive result were referred to a physician or health department for confirmatory testing and, if needed, HIV clinical care. Number of HIV tests completed and amount of time required to conduct testing. The 21 participating sites administered 1,540 HIV tests, with 1,087 conducted onsite by staff during regular working hours and 453 conducted at 37 different HIV testing events (e.g., local health fairs). The median amount of time required for pretest counseling/consent, waiting for test results, and posttest counseling was 4, 23, and 3 minutes, respectively. A majority of the sites (17) said they planned to continue HIV testing after the project period ended and would seek assistance or support from the local health department, a community-based organization, or an AIDS service organization. This pilot project established HIV testing in several community pharmacies and retail clinics to be a feasible model for offering rapid, point-of-care HIV testing. It also demonstrated the willingness and ability of staff at community pharmacies and retail clinics to provide confidential HIV testing to patients. Expanding this model to additional sites and evaluating its feasibility and effectiveness may serve unmet needs in urban and rural settings.
Bronner Murrison, Liza; Ananthakrishnan, Ramya; Sukumar, Sumanya; Augustine, Sheela; Krishnan, Nalini; Pai, Madhukar; Dowdy, David W
2016-01-01
Private practitioners are frequently the first point of healthcare contact for patients with tuberculosis (TB) in India. As new molecular tests are developed for point-of-care (POC) diagnosis of TB, it is imperative to understand these individuals' practices and preferences for POC testing. To evaluate rapid testing practices and identify priorities for novel POC TB tests among private practitioners in Chennai. We conducted a cross-sectional survey of 228 practitioners practicing in the private sector from January 2014 to February 2015 who saw at least one TB patient in the previous year. Practitioners were randomly selected from both the general community and a list of practitioners who referred patients to a public-private mix program for TB treatment. We used standardized questionnaires to collect data on current practices related to point-of-care diagnosis and interest in hypothetical POC tests. We used multivariable Poisson regression with robust estimates of standard error to calculate measures of association. Among 228 private practitioners, about half (48%) utilized any rapid testing in their current practice, most commonly for glucose (43%), pregnancy (21%), and malaria (5%). Providers using POC tests were more likely to work in hospitals (56% vs. 43%, P = 0.05) and less likely to be chest specialists (21% vs. 54%, P<0.001). Only half (51%) of providers would use a hypothetical POC test for TB that was accurate, equipment-free, and took 20 minutes to complete. Chest specialists were half as likely to express interest in performing the hypothetical POC TB test in-house as other practitioners (aPR 0.5, 95%CI: 0.2-0.9). Key challenges to performing POC testing for TB in this study included time constraints, easy access to local private labs and lack of an attached lab facility. As novel POC tests for TB are developed and scaled up, attention must be paid to integrating these diagnostics into healthcare providers' routine practice and addressing barriers for POC testing.
ERIC Educational Resources Information Center
Dorn, Lorah D.; Sontag-Padilla, Lisa M.; Pabst, Stephanie; Tissot, Abbigail; Susman, Elizabeth J.
2013-01-01
Age at menarche is critical in research and clinical settings, yet there is a dearth of studies examining its reliability in adolescents. We examined age at menarche during adolescence, specifically, (a) average method reliability across 3 years, (b) test-retest reliability between time points and methods, (c) intraindividual variability of…
James B. Johnson; Daniel Saenz; Cory K. Adams; Richard N. Conner
2003-01-01
Abstract: We tested the hypotheses that potential egg predators, crayfish Procambarus nigrocinctus and dytiscid Cybister sp. larvae, would accelerate the timing of hatching and that a larval predator, dragonfly naiad Anax junius, would delay hatching in the southern leopard frog (Rana...
Detectable changes in physical performance measures in elderly African Americans.
Mangione, Kathleen Kline; Craik, Rebecca L; McCormick, Alyson A; Blevins, Heather L; White, Meaghan B; Sullivan-Marx, Eileen M; Tomlinson, James D
2010-06-01
African American older adults have higher rates of self-reported disability and lower physical performance scores compared with white older adults. Measures of physical performance are used to predict future morbidity and to determine the effect of exercise. Characteristics of performance measures are not known for African American older adults. The purpose of this study was to estimate the standard error of measurement (SEM) and minimal detectable change (MDC) for the Short Physical Performance Battery (SPPB), Timed "Up & Go" Test (TUG) time, free gait speed, fast gait speed, and Six-Minute Walk Test (6MWT) distance in frail African American adults. This observational measurement study used a test-retest design. Individuals were tested 2 times over a 1-week period. Demographic data collected included height, weight, number of medications, assistive device use, and Mini-Mental Status Examination (MMSE) scores. Participants then completed the 5 physical performance tests. Fifty-two participants (mean age=78 years) completed the study. The average MMSE score was 25 points, and the average body mass index was 29.4 kg/m(2). On average, participants took 7 medications, and the majority used assistive devices. Intraclass correlation coefficients (ICC [2,1]) were greater than .90, except for the SPPB score (ICC=.81). The SEMs were 1.2 points for the SPPB, 1.7 seconds for the TUG, 0.08 m/s for free gait speed, 0.09 m/s for fast gait speed, and 28 m for 6MWT distance. The MDC values were 2.9 points for the SPPB, 4 seconds for the TUG, 0.19 m/s for free gait speed, 0.21 m/s for fast gait speed, and 65 m for 6MWT distance. The entire sample was from an urban area. The SEMs were similar to previously reported values and can be used when working with African American and white older adults. Estimates of MDC were calculated to assist in clinical interpretation.
Common Modular Multimode Radar (CMMR) Software Acquisition Study.
1981-03-01
MATEIAL .................................. A -1 APPENDIX B: POINTS OF CONTACT .................................... B-i APPENDIX C: F-i5, F-16, F/ A -iS... relook at a later time. 3.2.1.6 Low Altitude Navigation Targeting Infrared For Night (LANTIRN)-63249/2693 LANTIRN is scheduled to have production hardware...exit points for each module. As a result, the OFP can be easily read and tested, and revisions to the OFP can be easily undertaken and accomplished
Fast rockfall hazard assessment along a road section using the new LYNX Mobile Mapper Lidar
NASA Astrophysics Data System (ADS)
Dario, Carrea; Celine, Longchamp; Michel, Jaboyedoff; Marc, Choffet; Marc-Henri, Derron; Clement, Michoud; Andrea, Pedrazzini; Dario, Conforti; Michael, Leslar; William, Tompkinson
2010-05-01
The terrestrial laser scanning (TLS) is an active remote sensing technique providing high resolution point clouds of the topography. The high resolution digital elevations models (HRDEM) derived of these point clouds are an important tool for the stability analysis of slopes. The LYNX Mobile Mapper is a new TLS generation developed by Optech. Its particularity is to be mounted on a vehicle and providing a 360° high density point cloud at 200-khz measurement rate in a very short acquisition time. It is composed of two sensors improving the resolution and reducing the laser shadowing. The spatial resolution is better than 10 cm at 10 m range and at a velocity of 50 km/h and the reflectivity of the signal is around 20% at a distance of 200 m. The Lidar is also equipped with a DGPS and an inertial measurement unit (IMU) which gives real time position and georeferences directly the point cloud. Thanks to its ability to provide a continuous data set from an extended area along a road, this TLS system is useful for rockfall hazard assessment. In addition, this new scanner decrease considerably the time spent in the field and the postprocessing is reduced thanks to resultant georeferenced data. Nevertheless, its application is limited to an area close to the road. The LYNX has been tested near Pontarlier (France) along roads sections affected by rockfall. Regarding to the tectonic context, the studied area is located in the Folded Jura mainly composed of limestone. The result is a very detailed point cloud with a point spacing of 4 cm. The LYNX presents detailed topography on which a structural analysis has been carried out using COLTOP-3D. It allows obtaining a full structural description along the road. In addition, kinematic tests coupled with probabilistic analysis give a susceptibility map of the road cut or natural cliffs above the road. Comparisons with field survey confirm the Lidar approach.
Guest, Francesca L; Guest, Paul C
2017-01-01
This chapter describes how innovations that are driven by proteomic biomarker techniques can facilitate earlier and better treatment of patients who suffer from psychiatric disorders. The application of new micro-fluidic devices along with miniaturized biosensors and transducers will enable the development of handheld point-of-care testing instruments which can analyse a drop of a blood within the time span of a single visit to the doctor's office. It is anticipated that these approaches will incorporate both biochemical and clinical information, resulting in unique profiles for each test subject. These profiles can in turn be used to drive personalized medicine approaches in this devastating disease area. In addition, smartphone applications (apps) for self-monitoring will see increasing use for improved patient outcomes.
Tests of Gravity Using Lunar Laser Ranging.
Merkowitz, Stephen M
2010-01-01
Lunar laser ranging (LLR) has been a workhorse for testing general relativity over the past four decades. The three retroreflector arrays put on the Moon by the Apollo astronauts and the French built arrays on the Soviet Lunokhod rovers continue to be useful targets, and have provided the most stringent tests of the Strong Equivalence Principle and the time variation of Newton's gravitational constant. The relatively new ranging system at the Apache Point 3.5 meter telescope now routinely makes millimeter level range measurements. Incredibly, it has taken 40 years for ground station technology to advance to the point where characteristics of the lunar retroreflectors are limiting the precision of the range measurements. In this article, we review the gravitational science and technology of lunar laser ranging and discuss prospects for the future.
Tests of gravity Using Lunar Laser Ranging
NASA Technical Reports Server (NTRS)
Merkowitz, Stephen M.
2010-01-01
Lunar laser ranging (LLR) has been a workhorse for testing general relativity over the pat four decades. The three retrorefiector arrays put on the Moon by the Apollo astronauts and the French built array on the second Soviet Lunokhod rover continue to be useful targets, and have provided the most stringent tests of the Strong Equivalence Principle and the time variation of Newton's gravitational constant. The relatively new ranging system at the Apache Point :3.5 meter telescope now routinely makes millimeter level range measurements. Incredibly. it has taken 40 years for ground station technology to advance to the point where characteristics of the lunar retrorefiectors are limiting the precision of the range measurements. In this article. we review the gravitational science and technology of lunar laser ranging and discuss prospects for the future.
ERIC Educational Resources Information Center
Bokossa, Maxime C.; Huang, Gary G.
This report describes the imputation procedures used to deal with missing data in the National Education Longitudinal Study of 1988 (NELS:88), the only current National Center for Education Statistics (NCES) dataset that contains scores from cognitive tests given the same set of students at multiple time points. As is inevitable, cognitive test…
ERIC Educational Resources Information Center
Whiteman, Shawn D.; Jensen, Alexander C.; McHale, Susan M.
2017-01-01
This study built on research on sibling influences to assess potential bidirectional effects of older and younger siblings' risky behaviors on one another's risky behaviors; our longitudinal design allowed us to test these effects when siblings were at about the same chronological age, at different points in time. We also tested whether the…
Kim, Dae-Young; Seo, Byoung-Do; Choi, Pan-Am
2014-04-01
[Purpose] This study was conducted to determine the influence of Taekwondo as security martial arts training on anaerobic threshold, cardiorespiratory fitness, and blood lactate recovery. [Subjects and Methods] Fourteen healthy university students were recruited and divided into an exercise group and a control group (n = 7 in each group). The subjects who participated in the experiment were subjected to an exercise loading test in which anaerobic threshold, value of ventilation, oxygen uptake, maximal oxygen uptake, heart rate, and maximal values of ventilation / heart rate were measured during the exercise, immediately after maximum exercise loading, and at 1, 3, 5, 10, and 15 min of recovery. [Results] At the anaerobic threshold time point, the exercise group showed a significantly longer time to reach anaerobic threshold. The exercise group showed significantly higher values for the time to reach VO2max, maximal values of ventilation, maximal oxygen uptake and maximal values of ventilation / heart rate. Significant changes were observed in the value of ventilation volumes at the 1- and 5-min recovery time points within the exercise group; oxygen uptake and maximal oxygen uptake were significantly different at the 5- and 10-min time points; heart rate was significantly different at the 1- and 3-min time points; and maximal values of ventilation / heart rate was significantly different at the 5-min time point. The exercise group showed significant decreases in blood lactate levels at the 15- and 30-min recovery time points. [Conclusion] The study results revealed that Taekwondo as a security martial arts training increases the maximal oxygen uptake and anaerobic threshold and accelerates an individual's recovery to the normal state of cardiorespiratory fitness and blood lactate level. These results are expected to contribute to the execution of more effective security services in emergencies in which violence can occur.
Accelerated testing of composites
NASA Technical Reports Server (NTRS)
Papazian, H. A.
1983-01-01
It is shown that the Zhurkov method for testing the strength of solids can be applied to dynamic tension and to cyclic loading and provides a viable approach to accelerated testing of composites. Data from the literature are used to demonstrate a straightforward application of the method to dynamic tension of glass fiber and cyclic loading for glass/polymer, metal matrix, and graphite/epoxy composites. Zhurkov's equation can be used at relatively high loads to obtain failure times at any temperature of interest. By taking a few data points at one or two other temperatures the spectrum of failure times can be expanded to temperatures not easily accessible.
Lin, Min; Xu, XiaoWen; Wang, Yi; Hu, Yue; Zhao, Yu
2014-01-01
To evaluate the use of a levonorgestrel-releasing intrauterine system (LNG-IUS) for treating endometrial hyperplasia in patients with polycystic ovary syndrome (PCOS). LNG-IUSs were inserted in 60 PCOS patients with simple (40 cases), irregular (12 cases), or complex (8 cases) endometrial hyperplasia. Follow-ups were performed at 3, 6, 12, and 24 months after insertion. At each time point, changes in menstruation, hemoglobin level, and endometrial thickness and pathology were recorded. Menstrual changes were assessed with the Pictorial Blood Assessment Chart. Hemoglobin levels were measured by the Blood Routine Test. Endometrial thickness was determined by transvaginal ultrasound. Endometrial pathology was defined as simple, irregular, or complex endometrial hyperplasia by a pathologist after curettage. Outcomes at each time point were compared to baseline (pre-insertion) measurements by Student's t test or ANOVA (for multiple comparisons) with the post hoc Dunnett's test. Differences with a p < 0.05 were considered statistically significant. At all time points after LNG-IUS insertion and in all patients, menstrual blood loss was decreased and hemoglobin level was increased significantly compared to pre-insertion levels. The endometrial thickness was significantly reduced in all groups after 12 months. Most patients showed transformation of the endometrial pathology, with complete disappearance of simple and irregular cases of endometrial hyperplasia and a decreased number of complex endometrial hyperplasia cases. LNG-IUS is an effective, safe, nonsurgical, and atraumatic approach with few side effects for the treatment of endometrial hyperplasia in patients with PCOS. © 2014 S. Karger AG, Basel.
Economic and microbiologic evaluation of single-dose vial extension for hazardous drugs.
Rowe, Erinn C; Savage, Scott W; Rutala, William A; Weber, David J; Gergen-Teague, Maria; Eckel, Stephen F
2012-07-01
The update of US Pharmacopeia Chapter <797> in 2008 included guidelines stating that single-dose vials (SDVs) opened and maintained in an International Organization for Standardization Class 5 environment can be used for up to 6 hours after initial puncture. A study was conducted to evaluate the cost of discarding vials after 6 hours and to further test sterility of vials beyond this time point, subsequently defined as the beyond-use date (BUD). Financial determination of SDV waste included 2 months of retrospective review of all doses prescribed. Additionally, actual waste log data were collected. Active and control vials (prepared using sterilized trypticase soy broth) were recovered, instead of discarded, at the defined 6-hour BUD. The institution-specific waste of 19 selected SDV medications discarded at 6 hours was calculated at $766,000 annually, and tracking waste logs for these same medications was recorded at $770,000 annually. Microbiologic testing of vial extension beyond 6 hours showed that 11 (1.86%) of 592 samples had one colony-forming unit on one of two plates. Positive plates were negative at subsequent time points, and all positives were single isolates most likely introduced during the plating process. The cost of discarding vials at 6 hours was significant for hazardous medications in a large academic medical center. On the basis of microbiologic data, vial BUD extension demonstrated a contamination frequency of 1.86%, which likely represented exogenous contamination; vial BUD extension for the tested drugs showed no growth at subsequent time points and could provide an annual cost savings of more than $600,000.
Antoniou, A; Marmai, K; Qasem, F; Cherry, R; Jones, P M; Singh, S
2018-05-01
Informed consent is required before placing an epidural. At our hospital, teaching of residents about this is done informally at the bedside. This study aimed to assess the ability of anesthesia residents to acquire and retain knowledge required when seeking informed consent for epidural labor analgesia. It assessed how well this knowledge was translated to clinical ability, by assessing the verbal consent process during an interaction with a standardized patient. Twenty anesthesia residents were randomized to a 'didactic group' or a 'simulation group'. Each resident was presented with a written scenario and asked to document the informed consent process, as they normally would do (pre-test). The didactic group then had a presentation about informed consent, while the simulation group members interviewed a simulated patient, the scenarios focusing on different aspects of consent. All residents then read a scenario and documented their informed consent process (post-test). Six weeks later all residents interviewed a standardized patient in labor and documented the consent from this interaction (six-week test). There was no significant difference in the baseline performance of the two groups. Both groups showed significant improvement in their written consent documentation at the immediate time point, the improvement in the didactic group being greater. The didactic group performed better at both the immediate time point and the six-week time point. In this small study, a didactic teaching method proved better than simulation-based teaching in helping residents to gain knowledge needed to obtain informed consent for epidural labor analgesia. Copyright © 2017 Elsevier Ltd. All rights reserved.
1986-01-01
minal area, assess fetal heart tones with stethoscope , record FHTs, and remove equipment from area. or . Fetal Heart Tones, Doppler: Includes time to...activity to total 4 points. 5. Femoral OR pedal pulses OR fetal heart tones must be taken q 4 h . before you count the 2 points, but once again, since the... fetal heart tones OR tilt tests will count 2 points each if doneq 4 h or more frequently. If you had a patient with pedal pulses q 4 h AND fetal heart
Design and Laboratory Testing of a Prototype Linear Temperature Sensor
1982-07-01
computer, critical quantities such as the line sensor’s voltage, vertical position and, occasionally, a point sensor were also monitored in real time on a...REUT.............. ........... * 30 5.1 Linearity - Comparison With Thoy............... 31 5.2 Response Time ...from some initial time t 0 is more relevant to the measurement of internal waves (since the second term in 0 the above equation is usually small
Jones, Gary L; Won, Jong Ho; Drennan, Ward R; Rubinstein, Jay T
2013-01-01
Cochlear implant (CI) users can achieve remarkable speech understanding, but there is great variability in outcomes that is only partially accounted for by age, residual hearing, and duration of deafness. Results might be improved with the use of psychophysical tests to predict which sound processing strategies offer the best potential outcomes. In particular, the spectral-ripple discrimination test offers a time-efficient, nonlinguistic measure that is correlated with perception of both speech and music by CI users. Features that make this "one-point" test time-efficient, and thus potentially clinically useful, are also connected to controversy within the CI field about what the test measures. The current work examined the relationship between thresholds in the one-point spectral-ripple test, in which stimuli are presented acoustically, and interaction indices measured under the controlled conditions afforded by direct stimulation with a research processor. Results of these studies include the following: (1) within individual subjects there were large variations in the interaction index along the electrode array, (2) interaction indices generally decreased with increasing electrode separation, and (3) spectral-ripple discrimination improved with decreasing mean interaction index at electrode separations of one, three, and five electrodes. These results indicate that spectral-ripple discrimination thresholds can provide a useful metric of the spectral resolution of CI users.
Venkatesh, K; Nair, P S; Hoechter, D J; Buscher, H
2016-11-01
Haemostatic perturbations are commonly seen in extracorporeal membrane oxygenation (ECMO) patients and remain a clinical challenge, contributing significantly to morbidity and mortality. The approach to anticoagulation monitoring and the management of bleeding varies considerably across ECMO centres. Routine laboratory tests have their limitations in terms of turnaround time and specificity of information provided. Newer point-of-care testing (POCT) for coagulation may overcome these issues, as it provides information about the entire coagulation pathway from clot initiation to lysis. It is also possible to obtain qualitative information on platelet function from these tests. Furthermore, the ability to incorporate these results into a goal-directed algorithm to manage bleeding with targeted transfusion strategies appears particularly attractive and cost effective. Further studies are required to evaluate the utility of POCT to optimise bleeding and anticoagulation management in these complex patients.
Performance, emissions, and physical characteristics of a rotating combustion aircraft engine
NASA Technical Reports Server (NTRS)
Berkowitz, M.; Hermes, W. L.; Mount, R. E.; Myers, D.
1976-01-01
The RC2-75, a liquid cooled two chamber rotary combustion engine (Wankel type), designed for aircraft use, was tested and representative baseline (212 KW, 285 BHP) performance and emissions characteristics established. The testing included running fuel/air mixture control curves and varied ignition timing to permit selection of desirable and practical settings for running wide open throttle curves, propeller load curves, variable manifold pressure curves covering cruise conditions, and EPA cycle operating points. Performance and emissions data were recorded for all of the points run. In addition to the test data, information required to characterize the engine and evaluate its performance in aircraft use is provided over a range from one half to twice its present power. The exhaust emissions results are compared to the 1980 EPA requirements. Standard day take-off brake specific fuel consumption is 356 g/KW-HR (.585 lb/BHP-HR) for the configuration tested.
A modified split Hopkinson pressure bar for toughness tests
NASA Astrophysics Data System (ADS)
Granier, N.; Grunenwald, T.
2006-08-01
In order to characterize material toughness or to study crack arrest under dynamic loading conditions, a new testing device has been developed at CEA/Valduc. A new Split Hopkinson Pressure Bar (SHPB) has been modified: it is now composed of a single incident bar and a double transmitter bar. With this facility, a notched specimen can be loaded under three points bending conditions. Qualification tests with titanium and steel notched samples are presented. Data treatment software has been adapted to estimate the sample deflection as a function of time and treat the energy balance. These results are compared with classical Charpy experiments. Effect of various contact areas between specimen and bars are studied to point out their influence on obtained measurements. The advantage of a “knife” contact compared to a plane one is then clearly demonstrated. All results obtained with this new testing device are in good agreement and show a reduced scattering.
Standard of practice and Flynn Effect testimony in death penalty cases.
Gresham, Frank M; Reschly, Daniel J
2011-06-01
The Flynn Effect is a well-established psychometric fact documenting substantial increases in measured intelligence test performance over time. Flynn's (1984) review of the literature established that Americans gain approximately 0.3 points per year or 3 points per decade in measured intelligence. The accurate assessment and interpretation of intellectual functioning becomes critical in death penalty cases that seek to determine whether an individual meets the criteria for intellectual disability and thereby is ineligible for execution under Atkins v. Virginia (2002) . We reviewed the literature on the Flynn Effect and demonstrated how failure to adjust intelligence test scores based on this phenomenon invalidates test scores and may be in violation of the Standards for Educational and Psychological Testing as well as the "Ethical Principles for Psychologists and Code of Conduct." Application of the Flynn Effect and score adjustments for obsolete norms clearly is supported by science and should be implemented by practicing psychologists.
Hyper-X Research Vehicle (HXRV) Experimental Aerodynamics Test Program Overview
NASA Technical Reports Server (NTRS)
Holland, Scott D.; Woods, William C.; Engelund, Walter C.
2000-01-01
This paper provides an overview of the experimental aerodynamics test program to ensure mission success for the autonomous flight of the Hyper-X Research Vehicle (HXRV). The HXRV is a 12-ft long, 2700 lb lifting body technology demonstrator designed to flight demonstrate for the first time a fully airframe integrated scramjet propulsion system. Three flights are currently planned, two at Mach 7 and one at Mach 10, beginning in the fall of 2000. The research vehicles will be boosted to the prescribed scramjet engine test point where they will separate from the booster, stabilize. and initiate engine test. Following 5+ seconds of powered flight and 15 seconds of cowl-open tares, the cowl will close and the vehicle will fly a controlled deceleration trajectory which includes numerous control doublets for in-flight aerodynamic parameter identification. This paper reviews the preflight testing activities, wind tunnel models, test rationale. risk reduction activities, and sample results from wind tunnel tests supporting the flight trajectory of the HXRV from hypersonic engine test point through subsonic flight termination.
Hyper-X Research Vehicle (HXRV) Experimental Aerodynamics Test Program Overview
NASA Technical Reports Server (NTRS)
Holland, Scott D.; Woods, William C.; Engelund, Walter C.
2000-01-01
This paper provides an overview of the experimental aerodynamics test program to ensure mission success for the autonomous flight of the Hyper-X Research Vehicle (HXRV). The HXRV is a 12-ft long, 2700 lb lifting body technology demonstrator designed to flight demonstrate for the first time a fully airframe integrated scramjet propulsion system. Three flights are currently planned, two at Mach 7 and one at Mach 10, beginning in the fall of 2000. The research vehicles will be boosted to the prescribed scramjet engine test point where they will separate from the booster, stabilize, and initiate engine test. Following 5+ seconds of powered flight and 15 seconds of cow-open tares, the cowl will close and the vehicle will fly a controlled deceleration trajectory which includes numerous control doublets for in-flight aerodynamic parameter identification. This paper reviews the preflight testing activities, wind tunnel models, test rationale, risk reduction activities, and sample results from wind tunnel tests supporting the flight trajectory of the HXRV from hypersonic engine test point through subsonic flight termination.
Moser, Othmar; Eckstein, Max L; McCarthy, Olivia; Deere, Rachel; Bain, Stephen C; Haahr, Hanne L; Zijlstra, Eric; Bracken, Richard M
2017-01-01
To explore the impact of glycaemic control (HbA 1c ) on functional capacity during cardio-pulmonary exercise testing in people with type 1 diabetes. Sixty-four individuals with type 1 diabetes (age: 34 ± 8 years; 13 females, HbA 1c : 7.8 ± 1% (62 ± 13 mmol/mol), duration of diabetes: 17 ± 9 years) performed a cardio-pulmonary cycle ergometer exercise test until volitional exhaustion. Stepwise linear regression was used to explore relationships between HbA 1c and cardio-respiratory data with p ≤ 0.05. Furthermore, participants were divided into quartiles based on HbA 1c levels and cardio-respiratory data were analysed by one-way ANOVA. Multiple regression analysis was performed to explore the relationships between changes in time to exhaustion and cardio-respiratory data. Data were adjusted for confounder. HbA 1c was related to time to exhaustion and oxygen consumption at the power output elicited at the sub-maximal threshold of the heart rate turn point (r = 0.47, R 2 = 0.22, p = 0.03). Significant differences were found at time to exhaustion between Q I vs. Q IV and at oxygen consumption at the power output elicited at the heart rate turn point between Q I vs. Q II and Q I vs. Q IV (p < 0.05). Changes in oxygen uptake, power output and in oxygen consumption at the power output elicited at the heart rate turn point and at maximum power output explained 55% of the variance in time to exhaustion ( r = 0.74, R 2 = 0.55, p < 0.01). Poor glycaemic control is related to less economical use of oxygen at sub-maximal work rates and an earlier time to exhaustion during cardio-pulmonary exercise testing. However, exercise training could have the same potential to counteract the influence of poor glycaemic control on functional capacity. Trial registration NCT01704417. Date of registration: October 11, 2012.
Severin, Franziska; Borry, Pascal; Cornel, Martina C; Daniels, Norman; Fellmann, Florence; Victoria Hodgson, Shirley; Howard, Heidi C; John, Jürgen; Kääriäinen, Helena; Kayserili, Hülya; Kent, Alastair; Koerber, Florian; Kristoffersson, Ulf; Kroese, Mark; Lewis, Celine; Marckmann, Georg; Meyer, Peter; Pfeufer, Arne; Schmidtke, Jörg; Skirton, Heather; Tranebjærg, Lisbeth; Rogowski, Wolf H
2015-01-01
Given the cost constraints of the European health-care systems, criteria are needed to decide which genetic services to fund from the public budgets, if not all can be covered. To ensure that high-priority services are available equitably within and across the European countries, a shared set of prioritization criteria would be desirable. A decision process following the accountability for reasonableness framework was undertaken, including a multidisciplinary EuroGentest/PPPC-ESHG workshop to develop shared prioritization criteria. Resources are currently too limited to fund all the beneficial genetic testing services available in the next decade. Ethically and economically reflected prioritization criteria are needed. Prioritization should be based on considerations of medical benefit, health need and costs. Medical benefit includes evidence of benefit in terms of clinical benefit, benefit of information for important life decisions, benefit for other people apart from the person tested and the patient-specific likelihood of being affected by the condition tested for. It may be subject to a finite time window. Health need includes the severity of the condition tested for and its progression at the time of testing. Further discussion and better evidence is needed before clearly defined recommendations can be made or a prioritization algorithm proposed. To our knowledge, this is the first time a clinical society has initiated a decision process about health-care prioritization on a European level, following the principles of accountability for reasonableness. We provide points to consider to stimulate this debate across the EU and to serve as a reference for improving patient management. PMID:25248395
[Point-of-Care Testing in Trauma Patients - Methods and Evidence].
Dirkmann, Daniel; Britten, Martin W; Frey, Ulrich H
2018-06-01
In severely injured patients, trauma-induced coagulopathy (TIC) present at hospital admission is associated with increased transfusion requirements, morbidity and mortality. Early and effective treatment contributes to improved survival rates. Laboratory coagulation assays have long turn-around times and evidence for their usefulness, especially in the context of TIC, is weak. Due to the lack of appropriate guidance, transfusion of allogeneic blood products frequently follows a ratio-based concept (e.g., transfusion of erythrocytes and plasma in a 1 : 1 ratio). Point-of-care (PoC) tests enable the assessment of prothrombin time (PT) and activated partial thromboplastin time in few minutes. However, although normal PT in these tests allows to rule out relevant effects of several anticoagulants, they are not able to detect patients with TIC and/or requiring subsequent massive transfusion. Viscoelastic tests (VETs) make it possible to assess defects in thrombin generation, hypofibrinogenaemia, thrombocytopenia, and hyperfibrinolysis, and thus enable targeted therapy. Impairment of platelet function is the common blind spot not detectable using both standard laboratory-based tests and VETs. However, PoC platelet function tests enable to detect platelet defects and patients taking anti-platelet. Furthermore, impaired platelet function has been identified as a strong predictor for coagulopathy and massive transfusion in trauma patients. In other clinical settings, coagulation management based on VETs is associated with decreased transfusion requirements, incidence of acute kidney failure, and mortality, respectively. Data of the first small prospective randomised trial indicate superiority of VET guided coagulation management solely using coagulation factor concentrates, when compared to plasma transfusions in severe trauma. Georg Thieme Verlag KG Stuttgart · New York.
Severin, Franziska; Borry, Pascal; Cornel, Martina C; Daniels, Norman; Fellmann, Florence; Victoria Hodgson, Shirley; Howard, Heidi C; John, Jürgen; Kääriäinen, Helena; Kayserili, Hülya; Kent, Alastair; Koerber, Florian; Kristoffersson, Ulf; Kroese, Mark; Lewis, Celine; Marckmann, Georg; Meyer, Peter; Pfeufer, Arne; Schmidtke, Jörg; Skirton, Heather; Tranebjærg, Lisbeth; Rogowski, Wolf H
2015-06-01
Given the cost constraints of the European health-care systems, criteria are needed to decide which genetic services to fund from the public budgets, if not all can be covered. To ensure that high-priority services are available equitably within and across the European countries, a shared set of prioritization criteria would be desirable. A decision process following the accountability for reasonableness framework was undertaken, including a multidisciplinary EuroGentest/PPPC-ESHG workshop to develop shared prioritization criteria. Resources are currently too limited to fund all the beneficial genetic testing services available in the next decade. Ethically and economically reflected prioritization criteria are needed. Prioritization should be based on considerations of medical benefit, health need and costs. Medical benefit includes evidence of benefit in terms of clinical benefit, benefit of information for important life decisions, benefit for other people apart from the person tested and the patient-specific likelihood of being affected by the condition tested for. It may be subject to a finite time window. Health need includes the severity of the condition tested for and its progression at the time of testing. Further discussion and better evidence is needed before clearly defined recommendations can be made or a prioritization algorithm proposed. To our knowledge, this is the first time a clinical society has initiated a decision process about health-care prioritization on a European level, following the principles of accountability for reasonableness. We provide points to consider to stimulate this debate across the EU and to serve as a reference for improving patient management.
Traffic data collection and anonymous vehicle detection using wireless sensor networks.
DOT National Transportation Integrated Search
2012-05-01
New traffic sensing devices based on wireless sensing technologies were designed and tested. Such devices encompass a cost-effective, battery-free, and energy self-sustained architecture for real-time traffic measurement over distributed points in a ...
A quantitative evaluation of two methods for preserving hair samples
Roon, David A.; Waits, L.P.; Kendall, K.C.
2003-01-01
Hair samples are an increasingly important DNA source for wildlife studies, yet optimal storage methods and DNA degradation rates have not been rigorously evaluated. We tested amplification success rates over a one-year storage period for DNA extracted from brown bear (Ursus arctos) hair samples preserved using silica desiccation and -20C freezing. For three nuclear DNA microsatellites, success rates decreased significantly after a six-month time point, regardless of storage method. For a 1000 bp mitochondrial fragment, a similar decrease occurred after a two-week time point. Minimizing delays between collection and DNA extraction will maximize success rates for hair-based noninvasive genetic sampling projects.
Testing single point incremental forming molds for thermoforming operations
NASA Astrophysics Data System (ADS)
Afonso, Daniel; de Sousa, Ricardo Alves; Torcato, Ricardo
2016-10-01
Low pressure polymer processing processes as thermoforming or rotational molding use much simpler molds then high pressure processes like injection. However, despite the low forces involved with the process, molds manufacturing for this operations is still a very material, energy and time consuming operation. The goal of the research is to develop and validate a method for manufacturing plastically formed sheets metal molds by single point incremental forming (SPIF) operation for thermoforming operation. Stewart platform based SPIF machines allow the forming of thick metal sheets, granting the required structural stiffness for the mold surface, and keeping the short lead time manufacture and low thermal inertia.
Piskulic, Danijela; Liu, Lu; Cadenhead, Kristin S; Cannon, Tyrone D; Cornblatt, Barbara A; McGlashan, Thomas H; Perkins, Diana O; Seidman, Larry J; Tsuang, Ming T; Walker, Elaine F; Woods, Scott W; Bearden, Carrie E; Mathalon, Daniel H; Addington, Jean
2016-03-01
Deficits in social cognition are well established in schizophrenia and have been observed prior to the illness onset. Compared to healthy controls (HCs), individuals at clinical high risk of psychosis (CHR) are said to show deficits in social cognition similar to those observed in patients experiencing a first episode of psychosis. These deficits have been observed in several domains of social cognition, such as theory of mind (ToM), emotion perception and social perception. In the current study, the stability of three domains of social cognition (ToM, social perception and facial emotion perception) was assessed over time along and their association with both clinical symptoms and the later development of psychosis. Six hundred and seventy-five CHR individuals and 264 HC participants completed four tests of social cognition at baseline. Of those, 160 CHR and 155 HC participants completed assessments at all three time points (baseline, 1year and 2years) as part of their participation in the North American Prodrome Longitudinal Study. The CHR group performed poorer on all tests of social cognition across all time points compared to HCs. Social cognition was not associated with attenuated positive symptoms at any time point in the study. CHR individuals who developed a psychotic disorder during the course of the study did not differ in social cognition compared to those who did not develop psychosis. This longitudinal study demonstrated mild to moderate, but persistent ToM and social perception impairments in those at CHR for psychosis compared to HCs. Copyright © 2016 Elsevier B.V. All rights reserved.
Noy-Porat, Tal; Alcalay, Ron; Epstein, Eyal; Sabo, Tamar; Kronman, Chanoch; Mazor, Ohad
2017-03-01
The plant toxin ricin is considered a potential bioterror agent against which there is no available antidote. To date, neutralizing antibodies are the most promising post-exposure treatment for ricin intoxication, yet so far they were shown to be effective only when given within several hours post exposure. As part of an ongoing effort to develop efficient ricin-countermeasures, we tested whether high-affinity antibodies that were previously isolated from immunized non-human primates, may confer effective post-exposure therapy for ricin-intoxicated mice treated at late time-points after exposure. While each antibody is capable of providing high protection rate by itself, a formulation consisting of three neutralizing antibodies that target different epitopes was tested to provide therapeutic coverage against different variants of the malicious pathogen. Indeed, the tri-antibody based cocktail was highly effective, its administration resulting in very high survival rates (>70%) when animals were treated as late as 48 h post exposure and significant protection (>30%) even at 72 h. This study establishes for the first time that anti-ricin antibodies can serve as a highly effective antidote at such late time-points after exposure. From the clinical point of view, the extended therapeutic window documented here is of high importance allowing adequate time to accurately identify the causative agent and may permit initiation of life-saving treatment with these antibodies even after the onset of clinical signs. Copyright © 2017 Elsevier Ltd. All rights reserved.
An automated approach to measuring child movement and location in the early childhood classroom.
Irvin, Dwight W; Crutchfield, Stephen A; Greenwood, Charles R; Kearns, William D; Buzhardt, Jay
2018-06-01
Children's movement is an important issue in child development and outcome in early childhood research, intervention, and practice. Digital sensor technologies offer improvements in naturalistic movement measurement and analysis. We conducted validity and feasibility testing of a real-time, indoor mapping and location system (Ubisense, Inc.) within a preschool classroom. Real-time indoor mapping has several implications with respect to efficiently and conveniently: (a) determining the activity areas where children are spending the most and least time per day (e.g., music); and (b) mapping a focal child's atypical real-time movements (e.g., lapping behavior). We calibrated the accuracy of Ubisense point-by-point location estimates (i.e., X and Y coordinates) against laser rangefinder measurements using several stationary points and atypical movement patterns as reference standards. Our results indicate that activity areas occupied and atypical movement patterns could be plotted with an accuracy of 30.48 cm (1 ft) using a Ubisense transponder tag attached to the participating child's shirt. The accuracy parallels findings of other researchers employing Ubisense to study atypical movement patterns in individuals at risk for dementia in an assisted living facility. The feasibility of Ubisense was tested in an approximately 90-min assessment of two children, one typically developing and one with Down syndrome, during natural classroom activities, and the results proved positive. Implications for employing Ubisense in early childhood classrooms as a data-based decision-making tool to support children's development and its potential integration with other wearable sensor technologies are discussed.
Truccolo, Wilson
2017-01-01
This review presents a perspective on capturing collective dynamics in recorded neuronal ensembles based on multivariate point process models, inference of low-dimensional dynamics and coarse graining of spatiotemporal measurements. A general probabilistic framework for continuous time point processes reviewed, with an emphasis on multivariate nonlinear Hawkes processes with exogenous inputs. A point process generalized linear model (PP-GLM) framework for the estimation of discrete time multivariate nonlinear Hawkes processes is described. The approach is illustrated with the modeling of collective dynamics in neocortical neuronal ensembles recorded in human and non-human primates, and prediction of single-neuron spiking. A complementary approach to capture collective dynamics based on low-dimensional dynamics (“order parameters”) inferred via latent state-space models with point process observations is presented. The approach is illustrated by inferring and decoding low-dimensional dynamics in primate motor cortex during naturalistic reach and grasp movements. Finally, we briefly review hypothesis tests based on conditional inference and spatiotemporal coarse graining for assessing collective dynamics in recorded neuronal ensembles. PMID:28336305
Truccolo, Wilson
2016-11-01
This review presents a perspective on capturing collective dynamics in recorded neuronal ensembles based on multivariate point process models, inference of low-dimensional dynamics and coarse graining of spatiotemporal measurements. A general probabilistic framework for continuous time point processes reviewed, with an emphasis on multivariate nonlinear Hawkes processes with exogenous inputs. A point process generalized linear model (PP-GLM) framework for the estimation of discrete time multivariate nonlinear Hawkes processes is described. The approach is illustrated with the modeling of collective dynamics in neocortical neuronal ensembles recorded in human and non-human primates, and prediction of single-neuron spiking. A complementary approach to capture collective dynamics based on low-dimensional dynamics ("order parameters") inferred via latent state-space models with point process observations is presented. The approach is illustrated by inferring and decoding low-dimensional dynamics in primate motor cortex during naturalistic reach and grasp movements. Finally, we briefly review hypothesis tests based on conditional inference and spatiotemporal coarse graining for assessing collective dynamics in recorded neuronal ensembles. Published by Elsevier Ltd.
Applying the multivariate time-rescaling theorem to neural population models
Gerhard, Felipe; Haslinger, Robert; Pipa, Gordon
2011-01-01
Statistical models of neural activity are integral to modern neuroscience. Recently, interest has grown in modeling the spiking activity of populations of simultaneously recorded neurons to study the effects of correlations and functional connectivity on neural information processing. However any statistical model must be validated by an appropriate goodness-of-fit test. Kolmogorov-Smirnov tests based upon the time-rescaling theorem have proven to be useful for evaluating point-process-based statistical models of single-neuron spike trains. Here we discuss the extension of the time-rescaling theorem to the multivariate (neural population) case. We show that even in the presence of strong correlations between spike trains, models which neglect couplings between neurons can be erroneously passed by the univariate time-rescaling test. We present the multivariate version of the time-rescaling theorem, and provide a practical step-by-step procedure for applying it towards testing the sufficiency of neural population models. Using several simple analytically tractable models and also more complex simulated and real data sets, we demonstrate that important features of the population activity can only be detected using the multivariate extension of the test. PMID:21395436
Ye, Xin; Xu, Jin; Lu, Lijuan; Li, Xinxin; Fang, Xueen; Kong, Jilie
2018-08-14
The use of paper-based methods for clinical diagnostics is a rapidly expanding research topic attracting a great deal of interest. Some groups have attempted to realize an integrated nucleic acid test on a single microfluidic paper chip, including extraction, amplification, and readout functions. However, these studies were not able to overcome complex modification and fabrication requirements, long turn-around times, or the need for sophisticated equipment like pumps, thermal cyclers, or centrifuges. Here, we report an extremely simple paper-based test for the point-of-care diagnosis of rotavirus A, one of the most common pathogens that causes pediatric gastroenteritis. This paper-based test could perform nucleic acid extraction within 5 min, then took 25 min to amplify the target sequence, and the result was visible to the naked eye immediately afterward or quantitative by the UV-Vis absorbance. This low-cost method does not require extra equipment and is easy to use either in a lab or at the point-of-care. The detection limit for rotavirus A was found to be 1 × 10 3 copies/mL. In addition, 100% sensitivity and specificity were achieved when testing 48 clinical stool samples. In conclusion, the present paper-based test fulfills the main requirements for a point-of-care diagnostic tool, and has the potential to be applied to disease prevention, control, and precision diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.
Monothermal caloric screening test performance: a relative operating characteristic curve analysis.
Murnane, Owen D; Akin, Faith W; Lynn, Susan G; Cyr, David G
2009-06-01
The objective of the present study was to evaluate the performance of the monothermal caloric screening test in a large sample of patients. A retrospective analysis of the medical records of 1002 consecutive patients who had undergone vestibular assessment at the Mayo Clinic during the years 1989 and 1990 was conducted. Patients with incomplete alternate binaural bithermal (ABB) caloric testing, congenital or periodic alternating nystagmus, or bilateral vestibular loss were excluded from the study. Clinical decision theory analyses (relative operating characteristic curves) were used to determine the accuracy with which the monothermal warm (MWST) and monothermal cool (MCST) caloric screening tests predicted the results of the ABB caloric test. Cumulative distributions were constructed as a function of the cutoff points for monothermal interear difference (IED) to select the cutoff point associated with any combination of true-positive and false-positive rates. Both MWST and MCST performed well above chance level. The test performance for the MWST was significantly better than that of the MCST for three of the four ABB gold standards. A 10% IED cutoff point for the MWST yielded a false-negative rate of either 1% (UW >or=25%) or 3% (UW >or=20%). The use of a 10% IED (UW >or=25%) for the MWST would have resulted in a 40% reduction (N = 294) in the number of ABB caloric tests performed on patients without a unilateral weakness. The results of this study indicated that the MWST decreases test time without sacrificing the sensitivity of the ABB caloric test.
Muir-Hunter, Susan W; Graham, Laura; Montero Odasso, Manuel
2015-08-01
To measure test-retest and interrater reliability of the Berg Balance Scale (BBS) in community-dwelling adults with mild to moderate Alzheimer disease (AD). Method : A sample of 15 adults (mean age 80.20 [SD 5.03] years) with AD performed three balance tests: the BBS, timed up-and-go test (TUG), and Functional Reach Test (FRT). Both relative reliability, using the intra-class correlation coefficient (ICC), and absolute reliability, using standard error of measurement (SEM) and minimal detectable change (MDC95) values, were calculated; Bland-Altman plots were constructed to evaluate inter-tester agreement. The test-retest interval was 1 week. Results : For the BBS, relative reliability values were 0.95 (95% CI, 0.85-0.98) for test-retest reliability and 0.72 (95% CI, 0.31-0.91) for interrater reliability; SEM was 6.01 points and MDC95 was 16.66 points; and interrater agreement was 16.62 points. The BBS performed better in test-retest reliability than the TUG and FRT, tests with established reliability in AD. Between 33% and 50% of participants required cueing beyond standardized instructions because they were unable to remember test instructions. Conclusions : The BBS achieved relative reliability values that support its clinical utility, but MDC95 and agreement values indicate the scale has performance limitations in AD. Further research to optimize balance assessment for people with AD is required.
Jasińska-Stroschein, Magdalena; Kurczewska, Urszula; Orszulak-Michalak, Daria
2017-05-01
When performing in vitro dissolution testing, especially in the area of biowaivers, it is necessary to follow regulatory guidelines to minimize the risk of an unsafe or ineffective product being approved. The present study examines model-independent and model-dependent methods of comparing dissolution profiles based on various compared and contrasted international guidelines. Dissolution profiles for immediate release solid oral dosage forms were generated. The test material comprised tablets containing several substances, with at least 85% of the labeled amount dissolved within 15 min, 20-30 min, or 45 min. Dissolution profile similarity can vary with regard to the following criteria: time point selection (including the last time point), coefficient of variation, and statistical method selection. Variation between regulatory guidance and statistical methods can raise methodological questions and result potentially in a different outcome when reporting dissolution profile testing. The harmonization of existing guidelines would address existing problems concerning the interpretation of regulatory recommendations and research findings. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Brabcová, Dana; Kohout, Jiří; Weberová, Veronika; Komárek, Vladimír
2017-04-01
Stigma has been related to epilepsy since ancient times. Despite the importance of this issue, only a few interventions focusing on the reduction of epilepsy-related stigma may be found in the literature. Thus, the aim of this study is to evaluate the effectiveness of two interventions focused on the reduction of epilepsy-related stigma in children aged 9-11years. The first group of children involved in the study (n 1 =89) completed the 23-item Czech version of the SSE (Stigma Scale of Epilepsy) questionnaire and an 11-item multiple-choice knowledge test, then watched a video and completed the same questionnaire and test immediately after the intervention. The same procedure was used for the second group (n 2 =93) where a story was read by an instructor. Both groups were retested 6months later using the same methods. Both interventions resulted in long-term decrease of epilepsy-related stigma - the average value on SSE decreased from 55.15 points at baseline testing to 43.28 points in the 6-month follow-up for the case of the video (p<0.001) and from 48.68 points to 36.97 points for the case of the story (p<0.001). Knowledge about epilepsy was also significantly improved with the average result in the knowledge test increasing from 6.58 to 9.09 points in case of the video (p<0.001) and from 6.88 to 8.99 points in case of the story (p<0.001). The results showed that both aforementioned interventions were significant and effective ways to reduce epilepsy-related stigma in the given age group. Copyright © 2017 Elsevier Inc. All rights reserved.
Measurable residual disease testing in acute myeloid leukaemia.
Hourigan, C S; Gale, R P; Gormley, N J; Ossenkoppele, G J; Walter, R B
2017-07-01
There is considerable interest in developing techniques to detect and/or quantify remaining leukaemia cells termed measurable or, less precisely, minimal residual disease (MRD) in persons with acute myeloid leukaemia (AML) in complete remission defined by cytomorphological criteria. An important reason for AML MRD-testing is the possibility of estimating the likelihood (and timing) of leukaemia relapse. A perfect MRD-test would precisely quantify leukaemia cells biologically able and likely to cause leukaemia relapse within a defined interval. AML is genetically diverse and there is currently no uniform approach to detecting such cells. Several technologies focused on immune phenotype or cytogenetic and/or molecular abnormalities have been developed, each with advantages and disadvantages. Many studies report a positive MRD-test at diverse time points during AML therapy identifies persons with a higher risk of leukaemia relapse compared with those with a negative MRD-test even after adjusting for other prognostic and predictive variables. No MRD-test in AML has perfect sensitivity and specificity for relapse prediction at the cohort- or subject levels and there are substantial rates of false-positive and -negative tests. Despite these limitations, correlations between MRD-test results and relapse risk have generated interest in MRD-test result-directed therapy interventions. However, convincing proof that a specific intervention will reduce relapse risk in persons with a positive MRD-test is lacking and needs testing in randomized trials. Routine clinical use of MRD-testing requires further refinements and standardization/harmonization of assay platforms and results reporting. Such data are needed to determine whether results of MRD-testing can be used as a surrogate end point in AML therapy trials. This could make drug-testing more efficient and accelerate regulatory approvals. Although MRD-testing in AML has advanced substantially, much remains to be done.
Huang, Stephanie; Huang, He
2018-04-01
Discrete, rapid (i.e., ballistic like) muscle activation patterns have been observed in ankle muscles (i.e., plantar flexors and dorsiflexors) of able-bodied individuals during voluntary posture control. This observation motivated us to investigate whether transtibial amputees are capable of generating such a ballistic-like activation pattern accurately using their residual ankle muscles in order to assess whether the volitional postural control of a powered ankle prosthesis using proportional myoelectric control via residual muscles could be feasible. In this paper, we asked ten transtibial amputees to generate ballistic-like activation patterns using their residual lateral gastrocnemius and residual tibialis anterior to control a computer cursor via proportional myoelectric control to hit targets positioned at 20% and 40% of maximum voluntary contraction of the corresponding residual muscle. During practice conditions, we asked amputees to hit a single target repeatedly. During testing conditions, we asked amputees to hit a random sequence of targets. We compared movement time to target and end-point accuracy. We also examined motor recruitment synchronization via time-frequency representations of residual muscle activation. The result showed that median end-point error ranged from -0.6% to 1% maximum voluntary contraction across subjects during practice, which was significantly lower compared to testing ( ). Average movement time for all amputees was 242 ms during practice and 272 ms during testing. Motor recruitment synchronization varied across subjects, and amputees with the highest synchronization achieved the fastest movement times. End-point accuracy was independent of movement time. Results suggest that it is feasible for transtibial amputees to generate ballistic control signals using their residual muscles. Future work on volitional control of powered power ankle prostheses might consider anticipatory postural control based on ballistic-like residual muscle activation patterns and direct continuous proportional myoelectric control.
Stream Kriging: Incremental and recursive ordinary Kriging over spatiotemporal data streams
NASA Astrophysics Data System (ADS)
Zhong, Xu; Kealy, Allison; Duckham, Matt
2016-05-01
Ordinary Kriging is widely used for geospatial interpolation and estimation. Due to the O (n3) time complexity of solving the system of linear equations, ordinary Kriging for a large set of source points is computationally intensive. Conducting real-time Kriging interpolation over continuously varying spatiotemporal data streams can therefore be especially challenging. This paper develops and tests two new strategies for improving the performance of an ordinary Kriging interpolator adapted to a stream-processing environment. These strategies rely on the expectation that, over time, source data points will frequently refer to the same spatial locations (for example, where static sensor nodes are generating repeated observations of a dynamic field). First, an incremental strategy improves efficiency in cases where a relatively small proportion of previously processed spatial locations are absent from the source points at any given iteration. Second, a recursive strategy improves efficiency in cases where there is substantial set overlap between the sets of spatial locations of source points at the current and previous iterations. These two strategies are evaluated in terms of their computational efficiency in comparison to ordinary Kriging algorithm. The results show that these two strategies can reduce the time taken to perform the interpolation by up to 90%, and approach average-case time complexity of O (n2) when most but not all source points refer to the same locations over time. By combining the approaches developed in this paper with existing heuristic ordinary Kriging algorithms, the conclusions indicate how further efficiency gains could potentially be accrued. The work ultimately contributes to the development of online ordinary Kriging interpolation algorithms, capable of real-time spatial interpolation with large streaming data sets.
Point-of-care diagnostics: will the hurdles be overcome this time?
Huckle, David
2006-07-01
Point-of-care diagnostics have been proposed as the latest development in clinical diagnostics several times in the last 30 years; however, they have not yet fully developed into a business sector to match the projections. This perspective examines the reasons for past failures and the failure of technology to meet user needs. Advances have taken place in the last few years that effectively remove technology as a barrier to the development of point-of-care testing. Even regulatory issues regarding how products are developed and claims supported have been absorbed, understood and now accepted. The emphasis here is on the possible favorable aspects that are novel this time around. These changes have arisen as a result of the situation with global healthcare economics and the pressure from patients to be treated more like customers. The final hurdles relate to the conflict between diagnosis with the patient present and treated as soon as the point-of-care result is available and the entrenched positions of the central laboratory, the suppliers and their established distribution chains, and the way in which healthcare budgets are allocated. The ultimate hurdle that encapsulates all of these issues is reimbursement, which is the final barrier to a significant point-of-care diagnostics market--without reimbursement there will be no market.
Point-of-care testing in an organ procurement organization donor management setting.
Baier, K A; Markham, L E; Flaigle, S P; Nelson, P W; Shield, C F; Muruve, N A; Aeder, M I; Murillo, D; Bryan, C F
2003-01-01
Our organ procurement organization (OPO) evaluated the clinical and financial efficacy of point-of-care testing (POCT) in management of our deceased organ donors. Before we implemented point-of care testing with the i-STAT into routine clinical donor management, we compared the i-STAT result with the result from the respective donor hospital lab (DHL) for certain analytes on 15 consecutive donors in our OPO from 26 March to 14 May 2001. The financial impact was studied by reviewing 77 donors from July 2001 to March 2002. There was a strong correlation for each analyte between the POC and DHL test results with r-values as follows: pH 0.86; PCO2 = 0.96; PO2 = 0.98; sodium = 0.98; potassium = 0.95; chloride = 0.94; BUN = 0.98; glucose = 0.92; haematocrit = 0.87 and creatinine = 0.95. Since our OPO coordinators began using i-STAT in their routine clinical management of organ donors, they can now more quickly maximize oxygenation and fluid management of the donor and make extra-renal placement calls sooner. Finally, since we are no longer being billed for the testing performed on the i-STAT, average financial savings to our OPO are US dollars 733 per case. Point-of-care testing in management of our OPO donors provides a result that is equivalent to that of the donor hospital lab, has quicker turn-around time than the donor hospital laboratory, allowing more immediate clinical management decisions to be made so that extra-renal offers may begin sooner.
Weir, Nichola-Jane M; Pattison, Sally H; Kearney, Paddy; Stafford, Bob; Gormley, Gerard J; Crockard, Martin A; Gilpin, Deirdre F; Tunney, Michael M; Hughes, Carmel M
2018-01-01
Urinary Tract Infections (UTIs) are common bacterial infections, second only to respiratory tract infections and particularly prevalent within primary care. Conventional detection of UTIs is culture, however, return of results can take between 24 and 72 hours. The introduction of a point of care (POC) test would allow for more timely identification of UTIs, facilitating improved, targeted treatment. This study aimed to obtain consensus on the criteria required for a POC UTI test, to meet patient need within primary care. Criteria for consideration were compiled by the research team. These criteria were validated through a two-round Delphi process, utilising an expert panel of healthcare professionals from across Europe and United States of America. Using web-based questionnaires, panellists recorded their level of agreement with each criterion based on a 5-point Likert Scale, with space for comments. Using median response, interquartile range and comments provided, criteria were accepted/rejected/revised depending on pre-agreed cut-off scores. The first round questionnaire presented thirty-three criteria to the panel, of which 22 were accepted. Consensus was not achieved for the remaining 11 criteria. Following response review, one criterion was removed, while after revision, the remaining 10 criteria entered the second round. Of these, four were subsequently accepted, resulting in 26 criteria considered appropriate for a POC test to detect urinary infections. This study generated an approved set of criteria for a POC test to detect urinary infections. Criteria acceptance and comments provided by the healthcare professionals also supports the development of a multiplex point of care UTI test.
A fast image matching algorithm based on key points
NASA Astrophysics Data System (ADS)
Wang, Huilin; Wang, Ying; An, Ru; Yan, Peng
2014-05-01
Image matching is a very important technique in image processing. It has been widely used for object recognition and tracking, image retrieval, three-dimensional vision, change detection, aircraft position estimation, and multi-image registration. Based on the requirements of matching algorithm for craft navigation, such as speed, accuracy and adaptability, a fast key point image matching method is investigated and developed. The main research tasks includes: (1) Developing an improved celerity key point detection approach using self-adapting threshold of Features from Accelerated Segment Test (FAST). A method of calculating self-adapting threshold was introduced for images with different contrast. Hessian matrix was adopted to eliminate insecure edge points in order to obtain key points with higher stability. This approach in detecting key points has characteristics of small amount of computation, high positioning accuracy and strong anti-noise ability; (2) PCA-SIFT is utilized to describe key point. 128 dimensional vector are formed based on the SIFT method for the key points extracted. A low dimensional feature space was established by eigenvectors of all the key points, and each eigenvector was projected onto the feature space to form a low dimensional eigenvector. These key points were re-described by dimension-reduced eigenvectors. After reducing the dimension by the PCA, the descriptor was reduced to 20 dimensions from the original 128. This method can reduce dimensions of searching approximately near neighbors thereby increasing overall speed; (3) Distance ratio between the nearest neighbour and second nearest neighbour searching is regarded as the measurement criterion for initial matching points from which the original point pairs matched are obtained. Based on the analysis of the common methods (e.g. RANSAC (random sample consensus) and Hough transform cluster) used for elimination false matching point pairs, a heuristic local geometric restriction strategy is adopted to discard false matched point pairs further; and (4) Affine transformation model is introduced to correct coordinate difference between real-time image and reference image. This resulted in the matching of the two images. SPOT5 Remote sensing images captured at different date and airborne images captured with different flight attitude were used to test the performance of the method from matching accuracy, operation time and ability to overcome rotation. Results show the effectiveness of the approach.
Time- & Load-Dependence of Triboelectric Effect.
Pan, Shuaihang; Yin, Nian; Zhang, Zhinan
2018-02-06
Time- and load-dependent friction behavior is considered as important for a long time, due to its time-evolution and force-driving characteristics. However, its electronic behavior, mainly considered in triboelectric effect, has almost never been given the full attention and analyses from the above point of view. In this paper, by experimenting with fcc-latticed aluminum and copper friction pairs, the mechanical and electronic behaviors of friction contacts are correlated by time and load analyses, and the behind physical understanding is provided. Most importantly, the difference of "response lag" in force and electricity is discussed, the extreme points of coefficient of friction with the increasing normal loads are observed and explained with the surface properties and dynamical behaviors (i.e. wear), and the micro and macro theories linking tribo-electricity to normal load and wear (i.e. the physical explanation between coupled electrical and mechanical phenomena) are successfully developed and tested.
Tanaka, Yuji; Yamashita, Takako; Nagoshi, Masayasu
2017-04-01
Hydrocarbon contamination introduced during point, line and map analyses in a field emission electron probe microanalysis (FE-EPMA) was investigated to enable reliable quantitative analysis of trace amounts of carbon in steels. The increment of contamination on pure iron in point analysis is proportional to the number of iterations of beam irradiation, but not to the accumulated irradiation time. A combination of a longer dwell time and single measurement with a liquid nitrogen (LN2) trap as an anti-contamination device (ACD) is sufficient for a quantitative point analysis. However, in line and map analyses, contamination increases with irradiation time in addition to the number of iterations, even though the LN2 trap and a plasma cleaner are used as ACDs. Thus, a shorter dwell time and single measurement are preferred for line and map analyses, although it is difficult to eliminate the influence of contamination. While ring-like contamination around the irradiation point grows during electron-beam irradiation, contamination at the irradiation point increases during blanking time after irradiation. This can explain the increment of contamination in iterative point analysis as well as in line and map analyses. Among the ACDs, which are tested in this study, specimen heating at 373 K has a significant contamination inhibition effect. This technique makes it possible to obtain line and map analysis data with minimum influence of contamination. The above-mentioned FE-EPMA data are presented and discussed in terms of the contamination-formation mechanisms and the preferable experimental conditions for the quantification of trace carbon in steels. © The Author 2016. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Karanovic, Nenad; Carev, Mladen; Kardum, Goran; Pecotic, Renata; Valic, Maja; Karanovic, Sandra; Ujevic, Ante; Dogas, Zoran
2009-10-01
The profession of anaesthesiologist is demanding and potentially hazardous. Extended work shifts combined with intensive work load may adversely affect physicians' performance. The aim of this study was to explore the impact of a single in-hospital 24 h shift on the cognitive and psychomotor performance of anaesthesiologists in a surgical emergency department. Following ethical and institutional approval, 11 staff anaesthesiologists [six men, five women, age 48 (35-50), years of experience 17 (7-20), median (range)] successfully completed the study protocol. Four computer-generated psychological tests (CRD, Complex Reactionmeter Drenovac, Croatia) consisting of light signal position discrimination (CRD 311), simple visual orientation (CRD 21), simple arithmetic operations (CRD 11), and complex psychomotor coordination (CRD 411) were used to measure objective parameters of cognitive and psychomotor performance at four time points (D1 = 8:00 a.m., D2 = 3:00 p.m., D3 = 11:00 p.m.; and D4 = 7:00-8:00 a.m. next day) during the 24 h working day. The control testing on an ordinary working day was performed at two time points (C1 = 8:00 a.m., C2 = 3:00 p.m.). Three parameters were recorded: total test solving time (TTST), total variability, and total number of errors for all four tests. TTST was significantly impaired during the 24 h shift in all tests, and TTST was prolonged in CRD 21 test at different time points from 1.6 +/- 1.4 to 5.5 +/- 1.6 s compared with the control (F = 6.39, P = 0.001). The reaction times were prolonged from 1.3 +/- 1.8 to 5.4 +/- 1.2 s (F = 3.49, P = 0.009) in CRD 311, from 3.8 +/- 9.0 to 34.3 +/- 5.8 s (F = 5.05, P = 0.002) in CRD 11 TTST, and from 0.8 +/- 3.0 to 16.3 +/- 8.6 s (F = 2.67, P = 0.034) in CRD 411. Total variability was significantly altered during the 24 h shift only in CRD 411 (F = 2.63, P = 0.036). There was no difference in the total number of errors between the 24 h shift and the ordinary working day. Anaesthesiologists' 24 h working day in the emergency department altered cognitive and psychomotor function in comparison with ordinary working days. Speed, reliability and mental endurance (measured by TTST) were significantly impaired in all four tests. Stability and reaction time (measured by total variability) were only slightly impaired. Paradoxically, attention and alertness (measured by total number of errors) were not adversely affected. In conclusion, anaesthesiologists' psychomotor performance was impaired during the single 24 h shift.
Liu, Chong; Ji, Lailin; Yang, Lin; Zhao, Dongfeng; Zhang, Yanfeng; Liu, Dong; Zhu, Baoqiang; Lin, Zunqi
2016-04-01
In order to obtain the intensity distribution of a 351 nm focal spot and smoothing by spectral dispersion (SSD) focal plane profile of a SGII-upgraded facility, a type of off-axis imaging system with three spherical mirrors, suitable for a finite distance source point to be imaged near the diffraction limit has been designed. The quality factor of the image system is 1.6 times of the diffraction limit tested by a 1053 nm point source. Because of the absence of a 351 nm point source, we can use a Collins diffraction imaging integral with respect to λ=351 nm, corresponding to a quality factor that is 3.8 times the diffraction limit at 351 nm. The calibration results show that at least the range of ±10 mrad of view field angle and ±50 mm along the axial direction around the optimum object distance can be satisfied with near diffraction limited image that is consistent with the design value. Using this image system, the No. 2 beam of the SGII-upgraded facility has been tested. The test result of the focal spot of final optics assembly (FOA) at 351 nm indicates that about 80% of energy is encompassed in 14.1 times the diffraction limit, while the output energy of the No. 2 beam is 908 J at 1053 nm. According to convolution theorem, the true value of a 351 nm focal spot of FOA is about 12 times the diffraction limit because of the influence of the quality factor. Further experimental studies indicate that the RMS value along the smoothing direction is less than 15.98% in the SSD spot test experiment. Computer simulations show that the quality factor of the image system used in the experiment has almost no effect on the SSD focal spot test. The image system can remarkably distort the SSD focal spot distribution under the circumstance of the quality factor 15 times worse than the diffraction limit. The distorted image shows a steep slope in the contour of the SSD focal spot along the smoothing direction that otherwise has a relatively flat top region around the focal spot center.
1989-08-01
specific elements identified as useful for selection (Primoff & Eyde , 1988). The JEM approach uses a slightly different scale when test development is not...related to GATB scores and tests developed to measure specific elements (Primoff & Eyde , 1988). Of the ability taxonomies reviewed in this study, the...only formative at this point in time, the results of recent research in cognitive psychology and in use of the computer as a testing medium have not
Buffet test in the National Transonic Facility
NASA Technical Reports Server (NTRS)
Young, Clarence P., Jr.; Hergert, Dennis W.; Butler, Thomas W.; Herring, Fred M.
1992-01-01
A buffet test of a commercial transport model was accomplished in the National Transonic Facility at the NASA Langley Research Center. This aeroelastic test was unprecedented for this wind tunnel and posed a high risk for the facility. Presented here are the test results from a structural dynamics and aeroelastic response point of view. The activities required for the safety analysis and risk assessment are described. The test was conducted in the same manner as a flutter test and employed on-board dynamic instrumentation, real time dynamic data monitoring, and automatic and manual tunnel interlock systems for protecting the model.
Torabian, Kian; Lezzar, Dalia; Piety, Nathaniel Z; George, Alex; Shevkoplyas, Sergey S
2017-09-20
Sickle cell anemia (SCA) is a genetic blood disorder that is particularly lethal in early childhood. Universal newborn screening programs and subsequent early treatment are known to drastically reduce under-five SCA mortality. However, in resource-limited settings, cost and infrastructure constraints limit the effectiveness of laboratory-based SCA screening programs. To address this limitation our laboratory previously developed a low-cost, equipment-free, point-of-care, paper-based SCA test. Here, we improved the stability and performance of the test by replacing sodium hydrosulfite (HS), a key reducing agent in the hemoglobin solubility buffer which is not stable in aqueous solutions, with sodium metabisulfite (MS). The MS formulation of the test was compared to the HS formulation in a laboratory setting by inexperienced users ( n = 3), to determine visual limit of detection (LOD), readout time, diagnostic accuracy, intra- and inter-observer agreement, and shelf life. The MS test was found to have a 10% sickle hemoglobin LOD, 21-min readout time, 97.3% sensitivity and 99.5% specificity for SCA, almost perfect intra- and inter-observer agreement, at least 24 weeks of shelf stability at room temperature, and could be packaged into a self-contained, distributable test kits comprised of off-the-shelf disposable components and food-grade reagents with a total cost of only $0.21 (USD).
Lichtveld, Maureen Y.; Shankar, Arti; Mundorf, Chris; Hassan, Anna; Drury, Stacy
2016-01-01
The Scale to Assess the Therapeutic Relationship in Community Mental Health Care (STAR) is a frequently-administered tool for measuring therapeutic relationships between clinicians and patients. This manuscript tested the STAR’s psychometric properties within a community health worker (CHW)-led intervention study involving pregnant and postpartum women. Women (n = 141) enrolled in the study completed the 12-item participant STAR survey (STAR-P) at two time points over the course of pregnancy and at two time points after delivery. The factor structure of the STAR-P proved to be unstable with this population. However, a revised 9-item STAR-P revealed a two-factor model of positive and negative interactions, and demonstrated strong internal consistency at postpartum time points. The revised STAR-P shows strong psychometric properties, and is suitable for use to evaluate the relationship developed between CHWs and pregnant and postpartum women in an intervention program. PMID:27116361
Lichtveld, Maureen Y; Shankar, Arti; Mundorf, Chris; Hassan, Anna; Drury, Stacy
2016-12-01
The Scale to Assess the Therapeutic Relationship in Community Mental Health Care (STAR) is a frequently-administered tool for measuring therapeutic relationships between clinicians and patients. This manuscript tested the STAR's psychometric properties within a community health worker (CHW)-led intervention study involving pregnant and postpartum women. Women (n = 141) enrolled in the study completed the 12-item participant STAR survey (STAR-P) at two time points over the course of pregnancy and at two time points after delivery. The factor structure of the STAR-P proved to be unstable with this population. However, a revised 9-item STAR-P revealed a two-factor model of positive and negative interactions, and demonstrated strong internal consistency at postpartum time points. The revised STAR-P shows strong psychometric properties, and is suitable for use to evaluate the relationship developed between CHWs and pregnant and postpartum women in an intervention program.
Longitudinal Effects on Early Adolescent Language: A Twin Study
DeThorne, Laura Segebart; Smith, Jamie Mahurin; Betancourt, Mariana Aparicio; Petrill, Stephen A.
2016-01-01
Purpose We evaluated genetic and environmental contributions to individual differences in language skills during early adolescence, measured by both language sampling and standardized tests, and examined the extent to which these genetic and environmental effects are stable across time. Method We used structural equation modeling on latent factors to estimate additive genetic, shared environmental, and nonshared environmental effects on variance in standardized language skills (i.e., Formal Language) and productive language-sample measures (i.e., Productive Language) in a sample of 527 twins across 3 time points (mean ages 10–12 years). Results Individual differences in the Formal Language factor were influenced primarily by genetic factors at each age, whereas individual differences in the Productive Language factor were primarily due to nonshared environmental influences. For the Formal Language factor, the stability of genetic effects was high across all 3 time points. For the Productive Language factor, nonshared environmental effects showed low but statistically significant stability across adjacent time points. Conclusions The etiology of language outcomes may differ substantially depending on assessment context. In addition, the potential mechanisms for nonshared environmental influences on language development warrant further investigation. PMID:27732720
A soft-computing methodology for noninvasive time-spatial temperature estimation.
Teixeira, César A; Ruano, Maria Graça; Ruano, António E; Pereira, Wagner C A
2008-02-01
The safe and effective application of thermal therapies is restricted due to lack of reliable noninvasive temperature estimators. In this paper, the temporal echo-shifts of backscattered ultrasound signals, collected from a gel-based phantom, were tracked and assigned with the past temperature values as radial basis functions neural networks input information. The phantom was heated using a piston-like therapeutic ultrasound transducer. The neural models were assigned to estimate the temperature at different intensities and points arranged across the therapeutic transducer radial line (60 mm apart from the transducer face). Model inputs, as well as the number of neurons were selected using the multiobjective genetic algorithm (MOGA). The best attained models present, in average, a maximum absolute error less than 0.5 degrees C, which is pointed as the borderline between a reliable and an unreliable estimator in hyperthermia/diathermia. In order to test the spatial generalization capacity, the best models were tested using spatial points not yet assessed, and some of them presented a maximum absolute error inferior to 0.5 degrees C, being "elected" as the best models. It should be also stressed that these best models present implementational low-complexity, as desired for real-time applications.
Cytokine expression in response to root canal infection in gnotobiotic mice.
Maciel, K F; Neves de Brito, L C; Tavares, W L F; Moreira, G; Nicoli, J R; Vieira, L Q; Ribeiro Sobrinho, A P
2012-04-01
To examine cytokine expression profiles during periapical lesion development in response to synergetic human pathogens in a gnotobiotic mouse model. Human strains of Fusobacterium nucleatum and Peptostreptococcus prevotii were inoculated into the root canals of germ-free mice in either mono- or bi-association. Animals were killed 7 and 14 days after infection, and periapical tissues were collected. mRNA expression of the cytokines IFN-γ, TNF-α, Receptor activator of nuclear factor kappa-B ligand (RANKL), IL-10, IL-4 and transforming growth factor β (TGF-β) was assessed using real-time PCR. Levene's test was used to assess the equality of variance of the data, whereas a t-test for independent samples was used to evaluate the significance of the differences between groups (P < 0.05). The mRNA expression of IFN-γ and TNF-α was up-regulated by F. nucleatum during the acute (day 7) and chronic phase (day 14) of periapical lesion development. However, in bi-infection the expression of IFN-γ and TNF-α were effectively absent at both time-points. RANKL mRNA expression was down-regulated during dual infection at the chronic phase. As IL-4 expression was similar at both time-points, IL-4 does not appear to be involved in the periapical response to these bacterial strains. IL-10 was up-regulated during the chronic phase by mono-infection with either F. nucleatum or P. prevotii. Dual infection increased TGF-β mRNA expression on day 7, which paralleled the decrease in IFN-γ and TNF-α mRNA levels at the same time-point. F. nucleatum increased TGF-β mRNA expression during the chronic phase. Cytokine profiles depend on the nature of the bacterial challenge. Both TGF-β and IL-10 appeared to be regulating the proinflammatory cytokine responses at both time-points of the periapical immune response. © 2012 International Endodontic Journal.
Skinner, Andy; Woods, Andy T.; Lawrence, Natalia S.; Munafò, Marcus
2016-01-01
Computerised cognitive assessments are a vital tool in the behavioural sciences, but participants often view them as effortful and unengaging. One potential solution is to add gamelike elements to these tasks in order to make them more intrinsically enjoyable, and some researchers have posited that a more engaging task might produce higher quality data. This assumption, however, remains largely untested. We investigated the effects of gamelike features and test location on the data and enjoyment ratings from a simple cognitive task. We tested three gamified variants of the Go-No-Go task, delivered both in the laboratory and online. In the first version of the task participants were rewarded with points for performing optimally. The second version of the task was framed as a cowboy shootout. The third version was a standard Go-No-Go task, used as a control condition. We compared reaction time, accuracy and subjective measures of enjoyment and engagement between task variants and study location. We found points to be a highly suitable game mechanic for gamified cognitive testing because they did not disrupt the validity of the data collected but increased participant enjoyment. However, we found no evidence that gamelike features could increase engagement to the point where participant performance improved. We also found that while participants enjoyed the cowboy themed task, the difficulty of categorising the gamelike stimuli adversely affected participant performance, increasing No-Go error rates by 28% compared to the non-game control. Responses collected online vs. in the laboratory had slightly longer reaction times but were otherwise very similar, supporting other findings that online crowdsourcing is an acceptable method of data collection for this type of research. PMID:27441120
Optimizing Disaster Relief: Real-Time Operational and Tactical Decision Support
1993-01-01
efficiencies in completing the tAsks. Allocations recognize task priorities and the logistica l effects of geographic prox- imity, In addition...as if they ar~ collocated. Arcs connect loc-•I J>airs of zones to represent feasible dTrect point-to-point transportation and bear cost> ror...data to thl.’ de >~red level of aggregation. We have tested ARES manuall)’ ;mtl by replacins tbc deci~ion maker wrlh the decision simulator which
Acute Toxicity Evaluation of Nitroaromatic Compounds
1991-03-01
eye of any animal during the observation period. Extreme fluorescein staining was evident in all of the test animals. Pannus (corneal vasculation) was...treated eyes at this time point showed signs of pannus . 39 0 TABLE 13 ACUTE ORAL - RANGE FINDING - RATS 1,3,5-TRINITROBENZENE Dose Dose Wt (g) Wt (g) Wt...the cornea at the 24h, 48h, 72h and 96h observation points. Additional Observations: Pannus (corneal vascularization) was noted at the 96h observation
Input-output characterization of an ultrasonic testing system by digital signal analysis
NASA Technical Reports Server (NTRS)
Karaguelle, H.; Lee, S. S.; Williams, J., Jr.
1984-01-01
The input/output characteristics of an ultrasonic testing system used for stress wave factor measurements were studied. The fundamentals of digital signal processing are summarized. The inputs and outputs are digitized and processed in a microcomputer using digital signal processing techniques. The entire ultrasonic test system, including transducers and all electronic components, is modeled as a discrete-time linear shift-invariant system. Then the impulse response and frequency response of the continuous time ultrasonic test system are estimated by interpolating the defining points in the unit sample response and frequency response of the discrete time system. It is found that the ultrasonic test system behaves as a linear phase bandpass filter. Good results were obtained for rectangular pulse inputs of various amplitudes and durations and for tone burst inputs whose center frequencies are within the passband of the test system and for single cycle inputs of various amplitudes. The input/output limits on the linearity of the system are determined.
MacBurn's cylinder test problem
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shestakov, Aleksei I.
2016-02-29
This note describes test problem for MacBurn which illustrates its performance. The source is centered inside a cylinder with axial-extent-to-radius ratio s.t. each end receives 1/4 of the thermal energy. The source (fireball) is modeled as either a point or as disk of finite radius, as described by Marrs et al. For the latter, the disk is divided into 13 equal area segments, each approximated as a point source and models a partially occluded fireball. If the source is modeled as a single point, one obtains very nearly the expected deposition, e.g., 1/4 of the flux on each end andmore » energy is conserved. If the source is modeled as a disk, both conservation and energy fraction degrade. However, errors decrease if the source radius to domain size ratio decreases. Modeling the source as a disk increases run-times.« less
Vaughn, Amber E; Dearth-Wesley, Tracy; Tabak, Rachel G; Bryant, Maria; Ward, Dianne S
2017-02-01
Parents' food parenting practices influence children's dietary intake and risk for obesity and chronic disease. Understanding the influence and interactions between parents' practices and children's behavior is limited by a lack of development and psychometric testing and/or limited scope of current measures. The Home Self-Administered Tool for Environmental Assessment of Activity and Diet (HomeSTEAD) was created to address this gap. This article describes development and psychometric testing of the HomeSTEAD family food practices survey. Between August 2010 and May 2011, a convenience sample of 129 parents of children aged 3 to 12 years were recruited from central North Carolina and completed the self-administered HomeSTEAD survey on three occasions during a 12- to 18-day window. Demographic characteristics and child diet were assessed at Time 1. Child height and weight were measured during the in-home observations (following Time 1 survey). Exploratory factor analysis with Time 1 data was used to identify potential scales. Scales with more than three items were examined for scale reduction. Following this, mean scores were calculated at each time point. Construct validity was assessed by examining Spearman rank correlations between mean scores (Time 1) and children's diet (fruits and vegetables, sugar-sweetened beverages, snacks, sweets) and body mass index (BMI) z scores. Repeated measures analysis of variance was used to examine differences in mean scores between time points, and single-measure intraclass correlations were calculated to examine test-retest reliability between time points. Exploratory factor analysis identified 24 factors and retained 124 items; however, scale reduction narrowed items to 86. The final instrument captures five coercive control practices (16 items), seven autonomy support practices (24 items), and 12 structure practices (46 items). All scales demonstrated good internal reliability (α>.62), 18 factors demonstrated construct validity (significant association with child diet, P<0.05), and 22 demonstrated good reliability (intraclass correlation coefficient>0.61). The HomeSTEAD family food practices survey provides a brief, yet comprehensive and psychometrically sound assessment of food parenting practices. Copyright © 2017 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
Giallo, Rebecca; Gartland, Deirdre; Woolhouse, Hannah; Brown, Stephanie
2016-02-01
Depressive and fatigue symptoms are common health concerns for women in the postnatal period. Few studies have sought to investigate the role of fatigue in the development and maintenance of depressive symptoms. The aim of this paper was to examine the relationship between depressive symptoms and fatigue over the course of the first 4 years postpartum, in particular focusing on the extent to which fatigue at earlier time points predicted later depressive symptoms and vice versa. Data from over 1000 women participating in a longitudinal study of Australian women's physical and psychological health and recovery after childbirth were used. An autoregressive cross-lagged panel model was tested to assess the mutual influences of fatigue and depressive symptoms across five time points at 3, 6, 12 and 18 months postpartum, and at 4 years postpartum. A complex bidirectional relationship between fatigue and depressive symptoms from 3 months to 4 years postpartum was observed, where fatigue at earlier time points predicted depressive symptoms at later time points, and vice versa. The findings of this study suggest interventions targeting the prevention and management of fatigue may also confer some benefit in improving or preventing the development of depression symptoms in the early parenting period.
Neurocognitive Effects of Radiotherapy
2013-11-05
tensor imaging ( DTI ), perfusion and diffusion. The majority of patients have completed baseline and at least two additional time-points in regards...completed a 1 hour standard MRI as well as additional testing including diffuse tensor imaging ( DTI ), perfusion and diffusion. The majority of...including diffuse tensor imaging ( DTI ), perfusion and diffusion. The majority of patients have completed baseline and at least two additional time
This poster will present a modeling and mapping assessment of landscape sensitivity to non-point source pollution as applied to a hierarchy of catchment drainages in the Coastal Plain of the state of North Carolina. Analysis of the subsurface residence time of water in shallow a...
ERIC Educational Resources Information Center
Fauth, Elizabeth B.; Gerstorf, Denis; Ram, Nilam; Malmberg, Bo
2014-01-01
Developmental processes are inherently time-related, with various time metrics and transition points being used to proxy how change is organized with respect to the theoretically underlying mechanisms. Using data from 4 Swedish studies of individuals aged 70-100+ (N = 453) who were measured every 2 years for up to 5 waves, we tested whether…
Huong, Le Thi Thanh; Long, Tran Khanh; Son, Phung Xuan; Huyen, Do Phuc; Linh, Phan Thuy; Bich, Nguyen Ngoc; Lam, Nguyen Xuan; Anh, Le Vu; Tuyet-Hanh, Tran Thi
2016-01-01
Comprehensive bans on tobacco advertising and promotion were introduced through tobacco control legislation in Viet Nam, but it has been established that violations of the bans are very common. This study was conducted to explore the trend in violations of bans on tobacco advertising and promotion at points of sale in Viet Nam in the past six years and to explore any differences in the violation situations before and after the Law on Tobacco Control came into effect on 1st May 2013. Quantitative data were collected through observation of violations of the bans on tobacco advertising and promotion at points of sale in 10 provinces throughout Viet Nam in four survey rounds (2009, 2010, 2011, and 2015). Variation in violation prevalence over time was examined by chi-square test using a Bonferini method. Binary logistic regression was employed to identify the factors that may have influences on different types of violation. A level of significance of p<0.05 was used for all tests in this article. The most common form of violation was the display of more than one pack/one carton of a cigarette brand. Violation of bans on tobacco advertising increased while violations on promotion ban and on displaying tobacco decreased through time. Some factors associated with the tobacco advertising and promotion bans included surveyed years, types of points of sale, regions and areas where the points of sale were located. The enforcement of the bans did not improve even after the issuance and the enactment of the Law on Tobacco Control. This suggests that the monitoring and enforcement of bans on tobacco advertising and promotion at points of sale should be strengthened. Penalties should be strictly applied for violators as indicated in the current tobacco control legislation.
NASA Technical Reports Server (NTRS)
Byrne, E. J.
1979-01-01
Quantitative leak detector visually demonstrates refrigerant loss from precision volume of large refrigeration system over established period of time from single test point. Mechanical unit is less costly than electronic "sniffers" and is more reliable due to absence of electronic circuits that are susceptible to drift.
49 CFR 173.121 - Class 3-Assignment of packing group.
Code of Federal Regulations, 2013 CFR
2013-10-01
... than 100 L (26.3 gallons); and (iv) The viscosity and flash point are in accordance with the following... paragraph (b)(1) of this section shall be performed are as follows: (i) Viscosity test. The flow time in...
49 CFR 173.121 - Class 3-Assignment of packing group.
Code of Federal Regulations, 2014 CFR
2014-10-01
... than 100 L (26.3 gallons); and (iv) The viscosity and flash point are in accordance with the following... paragraph (b)(1) of this section shall be performed are as follows: (i) Viscosity test. The flow time in...
NASA Astrophysics Data System (ADS)
Hui, Z.; Cheng, P.; Ziggah, Y. Y.; Nie, Y.
2018-04-01
Filtering is a key step for most applications of airborne LiDAR point clouds. Although lots of filtering algorithms have been put forward in recent years, most of them suffer from parameters setting or thresholds adjusting, which will be time-consuming and reduce the degree of automation of the algorithm. To overcome this problem, this paper proposed a threshold-free filtering algorithm based on expectation-maximization. The proposed algorithm is developed based on an assumption that point clouds are seen as a mixture of Gaussian models. The separation of ground points and non-ground points from point clouds can be replaced as a separation of a mixed Gaussian model. Expectation-maximization (EM) is applied for realizing the separation. EM is used to calculate maximum likelihood estimates of the mixture parameters. Using the estimated parameters, the likelihoods of each point belonging to ground or object can be computed. After several iterations, point clouds can be labelled as the component with a larger likelihood. Furthermore, intensity information was also utilized to optimize the filtering results acquired using the EM method. The proposed algorithm was tested using two different datasets used in practice. Experimental results showed that the proposed method can filter non-ground points effectively. To quantitatively evaluate the proposed method, this paper adopted the dataset provided by the ISPRS for the test. The proposed algorithm can obtain a 4.48 % total error which is much lower than most of the eight classical filtering algorithms reported by the ISPRS.
Hatchette, Todd F; Bastien, Nathalie; Berry, Jody; Booth, Tim F; Chernesky, Max; Couillard, Michel; Drews, Steven; Ebsworth, Anthony; Fearon, Margaret; Fonseca, Kevin; Fox, Julie; Gagnon, Jean-Nicolas; Guercio, Steven; Horsman, Greg; Jorowski, Cathy; Kuschak, Theodore; Li, Yan; Majury, Anna; Petric, Martin; Ratnam, Sam; Smieja, Marek; Van Caeseele, Paul
2009-01-01
As the world prepares for the next influenza pandemic, governments have made significant funding commitments to vaccine development and antiviral stockpiling. While these are essential components to pandemic response, rapid and accurate diagnostic testing remains an often neglected cornerstone of pandemic influenza preparedness. Clinicians and Public Health Practitioners need to understand the benefits and drawbacks of different influenza tests in both seasonal and pandemic settings. Culture has been the traditional gold standard for influenza diagnosis but requires from 1-10 days to generate a positive result, compared to nucleic acid detection methods such as real time reverse transcriptase polymerase chain reaction (RT-PCR). Although the currently available rapid antigen detection kits can generate results in less than 30 minutes, their sensitivity is suboptimal and they are not recommended for the detection of novel influenza viruses. Until point-of-care (POC) tests are improved, PILPN recommends that the best option for pandemic influenza preparation is the enhancement of nucleic acid-based testing capabilities across Canada.
de Morton, Natalie A; Lane, Kylie
2010-11-01
To investigate the clinimetric properties of the de Morton Mobility Index (DEMMI) in a Geriatric Evaluation and Management (GEM) population. A longitudinal validation study (n = 100) and inter-rater reliability study (n = 29) in a GEM population. Consecutive patients admitted to a GEM rehabilitation ward were eligible for inclusion. At hospital admission and discharge, a physical therapist assessed patients with physical performance instruments that included the 6-metre walk test, step test, Clinical Test of Sensory Organization and Balance, Timed Up and Go test, 6-minute walk test and the DEMMI. Consecutively eligible patients were included in an inter-rater reliability study between physical therapists. DEMMI admission scores were normally distributed (mean 30.2, standard deviation 16.7) and other activity limitation instruments had either a floor or a ceiling effect. Evidence of convergent, discriminant and known groups validity for the DEMMI were obtained. The minimal detectable change with 90% confidence was 10.5 (95% confidence interval 6.1-17.9) points and the minimally clinically important difference was 8.4 points on the 100-point interval DEMMI scale. The DEMMI provides clinicians with an accurate and valid method of measuring mobility for geriatric patients in the subacute hospital setting.
Rennert, Hanna; Eng, Kenneth; Zhang, Tuo; Tan, Adrian; Xiang, Jenny; Romanel, Alessandro; Kim, Robert; Tam, Wayne; Liu, Yen-Chun; Bhinder, Bhavneet; Cyrta, Joanna; Beltran, Himisha; Robinson, Brian; Mosquera, Juan Miguel; Fernandes, Helen; Demichelis, Francesca; Sboner, Andrea; Kluk, Michael; Rubin, Mark A; Elemento, Olivier
2016-01-01
We describe Exome Cancer Test v1.0 (EXaCT-1), the first New York State-Department of Health-approved whole-exome sequencing (WES)-based test for precision cancer care. EXaCT-1 uses HaloPlex (Agilent) target enrichment followed by next-generation sequencing (Illumina) of tumour and matched constitutional control DNA. We present a detailed clinical development and validation pipeline suitable for simultaneous detection of somatic point/indel mutations and copy-number alterations (CNAs). A computational framework for data analysis, reporting and sign-out is also presented. For the validation, we tested EXaCT-1 on 57 tumours covering five distinct clinically relevant mutations. Results demonstrated elevated and uniform coverage compatible with clinical testing as well as complete concordance in variant quality metrics between formalin-fixed paraffin embedded and fresh-frozen tumours. Extensive sensitivity studies identified limits of detection threshold for point/indel mutations and CNAs. Prospective analysis of 337 cancer cases revealed mutations in clinically relevant genes in 82% of tumours, demonstrating that EXaCT-1 is an accurate and sensitive method for identifying actionable mutations, with reasonable costs and time, greatly expanding its utility for advanced cancer care. PMID:28781886
On-field mounting position estimation of a lidar sensor
NASA Astrophysics Data System (ADS)
Khan, Owes; Bergelt, René; Hardt, Wolfram
2017-10-01
In order to retrieve a highly accurate view of their environment, autonomous cars are often equipped with LiDAR sensors. These sensors deliver a three dimensional point cloud in their own co-ordinate frame, where the origin is the sensor itself. However, the common co-ordinate system required by HAD (Highly Autonomous Driving) software systems has its origin at the center of the vehicle's rear axle. Thus, a transformation of the acquired point clouds to car co-ordinates is necessary, and thereby the determination of the exact mounting position of the LiDAR system in car coordinates is required. Unfortunately, directly measuring this position is a time-consuming and error-prone task. Therefore, different approaches have been suggested for its estimation which mostly require an exhaustive test-setup and are again time-consuming to prepare. When preparing a high number of LiDAR mounted test vehicles for data acquisition, most approaches fall short due to time or money constraints. In this paper we propose an approach for mounting position estimation which features an easy execution and setup, thus making it feasible for on-field calibration.
Differences in Cognitive Outcomes After ECT Depending on BDNF and COMT Polymorphisms.
Bennett, Daniel Mark; Currie, James; Fernie, Gordon; Perrin, Jennifer S; Reid, Ian C
2016-12-01
The study aimed to explore cognitive outcomes after electroconvulsive therapy (ECT) depending on which version of common single nucleotide polymorphisms the patient expressed for brain-derived neurotrophic factor (BDNF) and catechol-O-methyltransferase (COMT). A total of 87 patients from the clinical ECT service in Aberdeen, Scotland, were included in the study. Cognitive function testing (using Spatial Recognition Memory task from the Cambridge Neuropsychological Test Automated Battery and Mini-Mental State Examination) and mood ratings (Montgomery-Åsberg Depression Rating Scale) were performed before ECT, after 4 treatments, at the end of ECT and 1 and 3 months after the end of treatment. These scores were compared depending on BDNF and COMT variant at each time point using the Student t test and using a time series generalized least squares random effects model. No differences were found between the val and met versions of the BDNF or COMT polymorphism in either cognitive or mood outcomes at any time point during ECT treatment or up to 3 months of follow-up. This study did not detect significant differences in cognitive or mood outcomes between patients who have the val66val or met versions of the BDNF polymorphism. Our results suggest that these polymorphisms will not be helpful in clinical practice for predicting cognitive outcomes after ECT.
Rahman, Nafisur; Kashif, Mohammad
2010-03-01
Point and interval hypothesis tests performed to validate two simple and economical, kinetic spectrophotometric methods for the assay of lansoprazole are described. The methods are based on the formation of chelate complex of the drug with Fe(III) and Zn(II). The reaction is followed spectrophotometrically by measuring the rate of change of absorbance of coloured chelates of the drug with Fe(III) and Zn(II) at 445 and 510 nm, respectively. The stoichiometric ratio of lansoprazole to Fe(III) and Zn(II) complexes were found to be 1:1 and 2:1, respectively. The initial-rate and fixed-time methods are adopted for determination of drug concentrations. The calibration graphs are linear in the range 50-200 µg ml⁻¹ (initial-rate method), 20-180 µg ml⁻¹ (fixed-time method) for lansoprazole-Fe(III) complex and 120-300 (initial-rate method), and 90-210 µg ml⁻¹ (fixed-time method) for lansoprazole-Zn(II) complex. The inter-day and intra-day precision data showed good accuracy and precision of the proposed procedure for analysis of lansoprazole. The point and interval hypothesis tests indicate that the proposed procedures are not biased. Copyright © 2010 John Wiley & Sons, Ltd.
NASA Technical Reports Server (NTRS)
Hogge, Edward F.; Kulkarni, Chetan S.; Vazquez, Sixto L.; Smalling, Kyle M.; Strom, Thomas H.; Hill, Boyd L.; Quach, Cuong C.
2017-01-01
This paper addresses the problem of building trust in the online prediction of a battery powered aircraft's remaining flying time. A series of flight tests is described that make use of a small electric powered unmanned aerial vehicle (eUAV) to verify the performance of the remaining flying time prediction algorithm. The estimate of remaining flying time is used to activate an alarm when the predicted remaining time is two minutes. This notifies the pilot to transition to the landing phase of the flight. A second alarm is activated when the battery charge falls below a specified limit threshold. This threshold is the point at which the battery energy reserve would no longer safely support two repeated aborted landing attempts. During the test series, the motor system is operated with the same predefined timed airspeed profile for each test. To test the robustness of the prediction, half of the tests were performed with, and half were performed without, a simulated powertrain fault. The pilot remotely engages a resistor bank at a specified time during the test flight to simulate a partial powertrain fault. The flying time prediction system is agnostic of the pilot's activation of the fault and must adapt to the vehicle's state. The time at which the limit threshold on battery charge is reached is then used to measure the accuracy of the remaining flying time predictions. Accuracy requirements for the alarms are considered and the results discussed.
ERIC Educational Resources Information Center
Sánchez-Rosas, Javier; Furlan, Luis Alberto
2017-01-01
Based on the control-value theory of achievement emotions and theory of achievement goals, this research provides evidence of convergent, divergent, and criterion validity of the Spanish Cognitive Test Anxiety Scale (S-CTAS). A sample of Argentinean undergraduates responded to several scales administered at three points. At time 1 and 3, the…
Rough-Water Tests of Models of the Vosper and Plum Planing Boats
NASA Technical Reports Server (NTRS)
Chambliss, Derrill B.; Blanchard, Ulysse J.
1950-01-01
Models of two types of high-speed surface craft were tested in Langley tank no. 1 to obtain rough-water data for an evaluation by the David Taylor .Model Basin of the relative merits of the designs. Time-history records were obtained of trim, rise, and normal acceleration at two points in the hulls for various speeds and two sizes of waves.
J.B. Puthoff; J.E. Jakes; H. Cao; D.S. Stone
2009-01-01
The development of nanoindentation test systems with high data collection speeds has made possible a novel type of indentation creep test: broadband nanoindentation creep (BNC). Using the high density of data points generated and analysis techniques that can model the instantaneous projected indent area at all times during a constant-load indentation experiment, BNC...
Internal Consistency of General Outcome Measures in Grades 1-8. Technical Report # 0915
ERIC Educational Resources Information Center
Anderson, Daniel; Tindal, Gerald; Alonzo, Julie
2009-01-01
We developed alternate forms of a math test for use in both screening students at risk of failure and monitoring their progress over time. In this technical report, we present results of the screener, used in the fall of 2009. The 48-item test was aligned to the National Council of Teachers of Mathematics (NCTM) Curriculum Focal Point Standards…
Have the temperature time series a structural change after 1998?
NASA Astrophysics Data System (ADS)
Werner, Rolf; Valev, Dimitare; Danov, Dimitar
2012-07-01
The global and hemisphere temperature GISS and Hadcrut3 time series were analysed for structural changes. We postulate the continuity of the preceding temperature function depending from the time. The slopes are calculated for a sequence of segments limited by time thresholds. We used a standard method, the restricted linear regression with dummy variables. We performed the calculations and tests for different number of thresholds. The thresholds are searched continuously in determined time intervals. The F-statistic is used to obtain the time points of the structural changes.
Wong, Rebecca; Levi, Angelique W; Harigopal, Malini; Schofield, Kevin; Chhieng, David C
2012-02-01
Our cytology laboratory, like many others, is under pressure to improve quality and provide test results faster while decreasing costs. We sought to address these issues by introducing new technology and lean principles. To determine the combined impact of the FocalPoint Guided Screener (GS) Imaging System (BD Diagnostics-TriPath, Burlington, North Carolina) and lean manufacturing principles on the turnaround time (TAT) and productivity of the gynecologic cytology operation. We established a baseline measure of the TAT for Papanicolaou tests. We then compared that to the performance after implementing the FocalPoint GS Imaging System and lean principles. The latter included value-stream mapping, workflow modification, and a first in-first out policy. The mean (SD) TAT for Papanicolaou tests before and after the implementation of FocalPoint GS Imaging System and lean principles was 4.38 (1.28) days and 3.20 (1.32) days, respectively. This represented a 27% improvement in the average TAT, which was statistically significant (P < .001). In addition, the productivity of staff improved 17%, as evidenced by the increase in slides screened from 8.85/h to 10.38/h. The false-negative fraction decreased from 1.4% to 0.9%, representing a 36% improvement. In our laboratory, the implementation of FocalPoint GS Imaging System in conjunction with lean principles resulted in a significant decrease in the average TAT for Papanicolaou tests and a substantial increase in the productivity of cytotechnologists while maintaining the diagnostic quality of gynecologic cytology.
Modeling and design of challenge tests: Inflammatory and metabolic biomarker study examples.
Gabrielsson, Johan; Hjorth, Stephan; Vogg, Barbara; Harlfinger, Stephanie; Gutierrez, Pablo Morentin; Peletier, Lambertus; Pehrson, Rikard; Davidsson, Pia
2015-01-25
Given the complexity of pharmacological challenge experiments, it is perhaps not surprising that design and analysis, and in turn interpretation and communication of results from a quantitative point of view, is often suboptimal. Here we report an inventory of common designs sampled from anti-inflammatory, respiratory and metabolic disease drug discovery studies, all of which are based on animal models of disease involving pharmacological and/or patho/physiological interaction challenges. The corresponding data are modeled and analyzed quantitatively, the merits of the respective approach discussed and inferences made with respect to future design improvements. Although our analysis is limited to these disease model examples, the challenge approach is generally applicable to the vast majority of pharmacological intervention studies. In the present five Case Studies results from pharmacodynamic effect models from different therapeutic areas were explored and analyzed according to five typical designs. Plasma exposures of test compounds were assayed by either liquid chromatography/mass spectrometry or ligand binding assays. To describe how drug intervention can regulate diverse processes, turnover models of test compound-challenger interaction, transduction processes, and biophase time courses were applied for biomarker response in eosinophil count, IL6 response, paw-swelling, TNFα response and glucose turnover in vivo. Case Study 1 shows results from intratracheal administration of Sephadex, which is a glucocorticoid-sensitive model of airway inflammation in rats. Eosinophils in bronchoalveolar fluid were obtained at different time points via destructive sampling and then regressed by the mixed-effects modeling. A biophase function of the Sephadex time course was inferred from the modeled eosinophil time courses. In Case Study 2, a mouse model showed that the time course of cytokine-induced IL1β challenge was altered with or without drug intervention. Anakinra reversed the IL1β induced cytokine IL6 response in a dose-dependent manner. This Case Study contained time courses of test compound (drug), challenger (IL1β) and cytokine response (IL6), which resulted in high parameter precision. Case Study 3 illustrates collagen-induced arthritis progression in the rat. Swelling scores (based on severity of hind paw swelling) were used to describe arthritis progression after the challenge and the inhibitory effect of two doses of an orally administered test compound. In Case Study 4, a cynomolgus monkey model for lipopolysaccharide LPS-induced TNFα synthesis and/or release was investigated. This model provides integrated information on pharmacokinetics and in vivo potency of the test compounds. Case Study 5 contains data from an oral glucose tolerance test in rats, where the challenger is the same as the pharmacodynamic response biomarker (glucose). It is therefore convenient to model the extra input of glucose simultaneously with baseline data and during intervention of a glucose-lowering compound at different dose levels. Typically time-series analyses of challenger- and biomarker-time data are necessary if an accurate and precise estimate of the pharmacodynamic properties of a test compound is sought. Erosion of data, resulting in the single-point assessment of drug action after a challenge test, should generally be avoided. This is particularly relevant for situations where one expects time-curve shifts, tolerance/rebound, impact of disease, or hormetic concentration-response relationships to occur. Copyright © 2014 Elsevier B.V. All rights reserved.
Mekenyan, Ovanes; Patlewicz, Grace; Dimitrova, Gergana; Kuseva, Chanita; Todorov, Milen; Stoeva, Stoyanka; Kotov, Stefan; Donner, E Maria
2010-10-18
Skin sensitization is an end point of concern for various legislation in the EU, including the seventh Amendment to the Cosmetics Directive and Registration Evaluation, Authorisation and Restriction of Chemicals (REACH). Since animal testing is a last resort for REACH or banned (from 2013 onward) for the Cosmetics Directive, the use of intelligent/integrated testing strategies (ITS) as an efficient means of gathering necessary information from alternative sources (e.g., in vitro, (Q)SARs, etc.) is gaining widespread interest. Previous studies have explored correlations between mutagenicity data and skin sensitization data as a means of exploiting information from surrogate end points. The work here compares the underlying chemical mechanisms for mutagenicity and skin sensitization in an effort to evaluate the role mutagenicity information can play as a predictor of skin sensitization potential. The Tissue Metabolism Simulator (TIMES) hybrid expert system was used to compare chemical mechanisms of both end points since it houses a comprehensive set of established structure-activity relationships for both skin sensitization and mutagenicity. The evaluation demonstrated that there is a great deal of overlap between skin sensitization and mutagenicity structural alerts and their underlying chemical mechanisms. The similarities and differences in chemical mechanisms are discussed in light of available experimental data. A number of new alerts for mutagenicity were also postulated for inclusion into TIMES. The results presented show that mutagenicity information can provide useful insights on skin sensitization potential as part of an ITS and should be considered prior to any in vivo skin sensitization testing being initiated.
NASA Astrophysics Data System (ADS)
Fischer, P.; Jardani, A.; Cardiff, M.; Lecoq, N.; Jourde, H.
2018-04-01
In a karstic field, the flow paths are very complex as they globally follow the conduit network. The responses generated from an investigation in this type of aquifer can be spatially highly variable. Therefore, the aim of the investigation in this case is to define a degree of connectivity between points of the field, in order to understand these flow paths. Harmonic pumping tests represent a possible investigation method for characterizing the subsurface flow of groundwater. They have several advantages compared to a constant-rate pumping (more signal possibilities, ease of extracting the signal in the responses and possibility of closed loop investigation). We show in this work that interpreting the responses from a harmonic pumping test is very useful for delineating a degree of connectivity between measurement points. We have firstly studied the amplitude and phase offset of responses from a harmonic pumping test in a theoretical synthetic modeling case in order to define a qualitative interpretation method in the time and frequency domains. Three different type of responses have been separated: a conduit connectivity response, a matrix connectivity, and a dual connectivity (response of a point in the matrix, but close to a conduit). We have then applied this method to measured responses at a field research site. Our interpretation method permits a quick and easy reconstruction of the main flow paths, and the whole set of field responses appear to give a similar range of responses to those seen in the theoretical synthetic case.
NASA Technical Reports Server (NTRS)
Chen, C. C.; Franklin, C. F.
1980-01-01
The frequency reuse capability is demonstrated for a Ku-band multiple beam antenna which provides contiguous low sidelobe spot beams for point-to-point communications between any two points within the continental United States (CONUS), or regional coverage beams for direct broadcast systems. A spot beam antenna in the 14/21 GHz band which provides contiguous overlapping beams covering CONUS and two discrete beams covering Hawaii and Alaska were designed, developed, and tested. Two reflector antennas are required for providing contiguous coverage of CONUS. Each is comprised of one offset parabolic reflector, one flat polarization diplexer, and two separate planar array feeds. This antenna system provides contiguous spot beam coverage of CONUS, utilizing 15 beams. Also designed, developed and demonstrated was a shaped contoured beam antenna system which provides contiguous four time zone coverage of CONUS from a single offset parabolic reflector incorporating one flat polarization diplexer and two separate planar array feeds. The beams which illuminate the eastern time zone and the mountain time zone are horizontally polarized, while the beams which illuminate the central time zone and the pacific time zone are vertically polarized. Frequency reuse is achieved by amplitude and polarization isolation.
Observing Bridge Dynamic Deflection in Green Time by Information Technology
NASA Astrophysics Data System (ADS)
Yu, Chengxin; Zhang, Guojian; Zhao, Yongqian; Chen, Mingzhi
2018-01-01
As traditional surveying methods are limited to observe bridge dynamic deflection; information technology is adopted to observe bridge dynamic deflection in Green time. Information technology used in this study means that we use digital cameras to photograph the bridge in red time as a zero image. Then, a series of successive images are photographed in green time. Deformation point targets are identified and located by Hough transform. With reference to the control points, the deformation values of these deformation points are obtained by differencing the successive images with a zero image, respectively. Results show that the average measurement accuracies of C0 are 0.46 pixels, 0.51 pixels and 0.74 pixels in X, Z and comprehensive direction. The average measurement accuracies of C1 are 0.43 pixels, 0.43 pixels and 0.67 pixels in X, Z and comprehensive direction in these tests. The maximal bridge deflection is 44.16mm, which is less than 75mm (Bridge deflection tolerance value). Information technology in this paper can monitor bridge dynamic deflection and depict deflection trend curves of the bridge in real time. It can provide data support for the site decisions to the bridge structure safety.
Individual differences in the forced swimming test and neurochemical kinetics in the rat brain.
Sequeira-Cordero, Andrey; Mora-Gallegos, Andrea; Cuenca-Berger, Patricia; Fornaguera-Trías, Jaime
2014-04-10
Individual differences in the forced swimming test (FST) could be associated with differential temporal dynamics of gene expression and neurotransmitter activity. We tested juvenile male rats in the FST and classified the animals into those with low and high immobility according to the amount of immobility time recorded in FST. These groups and a control group which did not undergo the FST were sacrificed either 1, 6 or 24 h after the test. We analyzed the expression of the CRF, CRFR1, BDNF and TrkB in the prefrontal cortex, hippocampus and nucleus accumbens as well as norepinephrine, dopamine, serotonin, glutamate, GABA and glutamine in the hippocampus and nucleus accumbens. Animals with low immobility showed significant reductions of BDNF expression across time points in both the prefrontal cortex and the nucleus accumbens when compared with non-swim control. Moreover, rats with high immobility only showed a significant decrease of BDNF expression in the prefrontal cortex 6h after the FST. Regarding neurotransmitters, only accumbal dopamine turnover and hippocampal glutamate content showed an effect of individual differences (i.e. animals with low and high immobility), whereas nearly all parameters showed significant differences across time points. Correlational analyses suggest that immobility in the FST, probably reflecting despair, is related to prefrontal cortical BDNF and to the kinetics observed in several other neurochemical parameters. Taken together, our results suggest that individual differences observed in depression-like behavior can be associated not only with changes in the concentrations of key neurochemical factors but also with differential time courses of such factors. Copyright © 2014 Elsevier Inc. All rights reserved.
Gaw, James R; Crowley, Steven; Monagle, Paul; Jones, Sophie; Newall, Fiona
2013-07-01
The use of point-of-care (POC) devices within the home for routine INR monitoring has demonstrated reliability, safety and effectiveness in the management of infants and children requiring long-term warfarin therapy. However, a comprehensive cost-analysis of using this method of management, compared to attending anticoagulation clinics has not been reported. The aim of this study was to compare the estimated societal costs of attending anticoagulation clinics for routine INR monitoring to using a POC test in the home. This study used a comparative before-and-after design that included 60 infants and children managed via the Haematology department at a tertiary paediatric centre. Each participant was exposed to both modes of management at various times for a period of ≥3 months. A questionnaire, consisting of 25 questions was sent to families to complete and return. Data collected included: the frequency of monitoring, mode of travel to and from clinics, total time consumed, and primary carer's income level. The home monitoring cohort saved a total of 1 hour 19 minutes per INR test compared to attending anticoagulation clinics and had a cost saving to society of $66.83 (AUD) per INR test compared to traditional care; incorporating health sector costs, travel expenses and lost time. The traditional model of care requires a considerable investment of time per test from both child and carer. Home INR monitoring in infants and children provides greater societal economic benefits compared to traditional models. Copyright © 2013 Elsevier Ltd. All rights reserved.
Rutala, William A; Kanamori, Hajime; Gergen, Maria; Sickbert-Bennett, Emily; Anderson, Deverick; Sexton, Daniel; Weber, David J
2017-01-01
Abstract Background Healthcare room environmental surfaces can be frequently and continuously contaminated with multidrug-resistant organisms (MDROs) that can persist in the environment for a prolonged time. Here, we used a dilute hydrogen peroxide (DHP) gas system for continuous room decontamination and experimentally examined the germicidal efficacy of the new technology against MDROs. Methods DHP units were installed in ceilings of a model room and the hallway in front of the room. We tested three test organisms; methicillin-resistant staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus (VRE), and MDR-Acinetobacter baumannii. An estimated 100–500 CFU for each test organism was inoculated and spread separately on each Formica sheet then exposed to DHP gas released into the room air. Triplicate samples were collected at times 0, 1, 3, 5, 6, 7, 24, and 48 hours. Following incubation, the colony forming units (CFU) of the test organisms on each Rodac plate were counted. Two separate experimental trials were performed for all time points. Statistical significance between intervention and control groups at each time point was determined by the Wilcoxon test, and P < 0.05 was considered significant. Results There were no statistical differences in survival between DHP intervention and control groups except data at very few time points for each organism (i.e., for MRSA in Figure 1, P = 0.0063 at 24 hours; for VRE in Figure 2, P = 0.0163 at 1 hour, P = 0.0163 at 3 hours; for MDR-Acinetobacter in in Figure 3, P = 0.0369 at 24 hours). The survival curves between both groups for each organism intersected at around 24 hours. The DHP units maintained a germicidal concentration (<0.3ppm for all runs) that was inadequate, despite attempts to control factors that could interfere with the hydrogen peroxide gas concentration. Conclusion Our preliminary study using DHP demonstrated inactivity against MDROs on room surfaces, likely because we were unable to generate a sufficient germicidal level under our test conditions with the particular DHP units. Additional technologic modifications would be required to maintain stable and effective DHP level for continuous room decontamination in patient rooms. Disclosures D. Sexton, Centers for Disease Control and Prevention: Grant Investigator, Grant recipient. Centers for Disease Control and Prevention Foundation: Grant Investigator, Grant recipient. UpToDate: Collaborator, Royalty Recipient. D. J. Weber, PDI: Consultant, Consulting fee.
Early Steps in Automated Behavior Mapping via Indoor Sensors.
Arsan, Taner; Kepez, Orcun
2017-12-16
Behavior mapping (BM) is a spatial data collection technique in which the locational and behavioral information of a user is noted on a plan layout of the studied environment. Among many indoor positioning technologies, we chose Wi-Fi, BLE beacon and ultra-wide band (UWB) sensor technologies for their popularity and investigated their applicability in BM. We tested three technologies for error ranges and found an average error of 1.39 m for Wi-Fi in a 36 m² test area (6 m × 6 m), 0.86 m for the BLE beacon in a 37.44 m² test area (9.6 m × 3.9 m) and 0.24 m for ultra-wide band sensors in a 36 m² test area (6 m × 6 m). We simulated the applicability of these error ranges for real-time locations by using a behavioral dataset collected from an active learning classroom. We used two UWB tags simultaneously by incorporating a custom-designed ceiling system in a new 39.76 m² test area (7.35 m × 5.41 m). We considered 26 observation points and collected data for 180 s for each point (total 4680) with an average error of 0.2072 m for 23 points inside the test area. Finally, we demonstrated the use of ultra-wide band sensor technology for BM.
Early Steps in Automated Behavior Mapping via Indoor Sensors
Arsan, Taner
2017-01-01
Behavior mapping (BM) is a spatial data collection technique in which the locational and behavioral information of a user is noted on a plan layout of the studied environment. Among many indoor positioning technologies, we chose Wi-Fi, BLE beacon and ultra-wide band (UWB) sensor technologies for their popularity and investigated their applicability in BM. We tested three technologies for error ranges and found an average error of 1.39 m for Wi-Fi in a 36 m2 test area (6 m × 6 m), 0.86 m for the BLE beacon in a 37.44 m2 test area (9.6 m × 3.9 m) and 0.24 m for ultra-wide band sensors in a 36 m2 test area (6 m × 6 m). We simulated the applicability of these error ranges for real-time locations by using a behavioral dataset collected from an active learning classroom. We used two UWB tags simultaneously by incorporating a custom-designed ceiling system in a new 39.76 m2 test area (7.35 m × 5.41 m). We considered 26 observation points and collected data for 180 s for each point (total 4680) with an average error of 0.2072 m for 23 points inside the test area. Finally, we demonstrated the use of ultra-wide band sensor technology for BM. PMID:29258178
Effect of area ratio on the performance of a 5.5:1 pressure ratio centrifugal impeller
NASA Technical Reports Server (NTRS)
Schumann, L. F.; Clark, D. A.; Wood, J. R.
1986-01-01
A centrifugal impeller which was initially designed for a pressure ratio of approximately 5.5 and a mass flow rate of 0.959 kg/sec was tested with a vaneless diffuser for a range of design point impeller area ratios from 2.322 to 2.945. The impeller area ratio was changed by successively cutting back the impeller exit axial width from an initial value of 7.57 mm to a final value of 5.97 mm. In all, four separate area ratios were tested. For each area ratio a series of impeller exit axial clearances was also tested. Test results are based on impeller exit surveys of total pressure, total temperature, and flow angle at a radius 1.115 times the impeller exit radius. Results of the tests at design speed, peak efficiency, and an exit tip clearance of 8 percent of exit blade height show that the impeller equivalent pressure recovery coefficient peaked at a design point area ratio of approximately 2.748 while the impeller aerodynamic efficiency peaked at a lower value of area ratio of approximately 2.55. The variation of impeller efficiency with clearance showed expected trends with a loss of approximately 0.4 points in impeller efficiency for each percent increase in exit axial tip clearance for all impellers tested.
The Use of Computer Vision Algorithms for Automatic Orientation of Terrestrial Laser Scanning Data
NASA Astrophysics Data System (ADS)
Markiewicz, Jakub Stefan
2016-06-01
The paper presents analysis of the orientation of terrestrial laser scanning (TLS) data. In the proposed data processing methodology, point clouds are considered as panoramic images enriched by the depth map. Computer vision (CV) algorithms are used for orientation, which are applied for testing the correctness of the detection of tie points and time of computations, and for assessing difficulties in their implementation. The BRISK, FASRT, MSER, SIFT, SURF, ASIFT and CenSurE algorithms are used to search for key-points. The source data are point clouds acquired using a Z+F 5006h terrestrial laser scanner on the ruins of Iłża Castle, Poland. Algorithms allowing combination of the photogrammetric and CV approaches are also presented.
2017-01-01
Abstract Objective: To analyse the metric properties of the Timed Get up and Go-Modified Version Test (TGUGM), in risk assessment of falls in a group of physically active women. Methods: A sample was constituted by 202 women over 55 years of age, were assessed through a crosssectional study. The TGUGM was applied to assess their fall risk. The test was analysed by comparison of the qualitative and quantitative information and by factor analysis. The development of a logistic regression model explained the risk of falls according to the test components. Results: The TGUGM was useful for assessing the risk of falls in the studied group. The test revealed two factors: the Get Up and the Gait with dual task. Less than twelve points in the evaluation or runtimes higher than 35 seconds was associated with high risk of falling. More than 35 seconds in the test indicated a risk fall probability greater than 0.50. Also, scores less than 12 points were associated with a delay of 7 seconds more in the execution of the test (p= 0.0016). Conclusions: Factor analysis of TGUGM revealed two dimensions that can be independent predictors of risk of falling: The Get up that explains between 64% and 87% of the risk of falling, and the Gait with dual task, that explains between 77% and 95% of risk of falling. PMID:28559642
Flight Test Identification and Simulation of a UH-60A Helicopter and Slung Load
NASA Technical Reports Server (NTRS)
Cicolani, Luigi S.; Sahai, Ranjana; Tucker, George E.; McCoy, Allen H.; Tyson, Peter H.; Tischler, Mark B.; Rosen, Aviv
2001-01-01
Helicopter slung-load operations are common in both military and civil contexts. Helicopters and loads are often qualified for these operations by means of flight tests, which can be expensive and time consuming. There is significant potential to reduce such costs both through revisions in flight-test methods and by using validated simulation models. To these ends, flight tests were conducted at Moffett Field to demonstrate the identification of key dynamic parameters during flight tests (aircraft stability margins and handling-qualities parameters, and load pendulum stability), and to accumulate a data base for simulation development and validation. The test aircraft was a UH-60A Black Hawk, and the primary test load was an instrumented 8- by 6- by 6-ft cargo container. Tests were focused on the lateral and longitudinal axes, which are the axes most affected by the load pendulum modes in the frequency range of interest for handling qualities; tests were conducted at airspeeds from hover to 80 knots. Using telemetered data, the dynamic parameters were evaluated in near real time after each test airspeed and before clearing the aircraft to the next test point. These computations were completed in under 1 min. A simulation model was implemented by integrating an advanced model of the UH-60A aerodynamics, dynamic equations for the two-body slung-load system, and load static aerodynamics obtained from wind-tunnel measurements. Comparisons with flight data for the helicopter alone and with a slung load showed good overall agreement for all parameters and test points; however, unmodeled secondary dynamic losses around 2 Hz were found in the helicopter model and they resulted in conservative stability margin estimates.
Quan, Erik; Mahmood, Rizwan; Naik, Amar; Sargon, Peter; Shastri, Nikhil; Venu, Mukund; Parada, Jorge P; Gupta, Neil
2018-05-21
There have been reported outbreaks of carbapenem-resistant Enterobacteriaceae infections linked to endoscopes with elevator mechanisms. Adenosine triphosphate (ATP) testing has been used as a marker for bioburden and monitoring manual cleaning for flexible endoscopes with and without an elevator mechanism. The objective of this study was to determine whether routine ATP testing could identify areas of improvement in cleaning of endoscopes with an elevator mechanism. ATP testing after manual cleaning of TJF-Q180V duodenoscopes and GF-UCT180 linear echoendoscopes (Olympus America Inc, Center Valley, PA) was implemented. Samples were tested from the distal end, the elevator mechanism, and water flushed through the lumen of the biopsy channel. Data were recorded and compared by time point, test point, and reprocessing technician. Overall failure rate was 6.99% (295 out of 4,219). The highest percentage of failed ATP tests (17.05%) was reported in the first quarter of routine testing, with an overall decrease in rates over time. The elevator mechanism and working channel lumen had higher failure rates than the distal end. Quality of manual cleaning between reprocessing technicians showed variation. ATP testing is effective in identifying residual organic material and improving quality of manual cleaning of endoscopes with an elevator mechanism. Cleaning efficacy is influenced by reprocessing technicians and location tested on the endoscope. Close attention to the working channel and elevator mechanism during manual cleaning is warranted. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Determination of end point of primary drying in freeze-drying process control.
Patel, Sajal M; Doen, Takayuki; Pikal, Michael J
2010-03-01
Freeze-drying is a relatively expensive process requiring long processing time, and hence one of the key objectives during freeze-drying process development is to minimize the primary drying time, which is the longest of the three steps in freeze-drying. However, increasing the shelf temperature into secondary drying before all of the ice is removed from the product will likely cause collapse or eutectic melt. Thus, from product quality as well as process economics standpoint, it is very critical to detect the end of primary drying. Experiments were conducted with 5% mannitol and 5% sucrose as model systems. The apparent end point of primary drying was determined by comparative pressure measurement (i.e., Pirani vs. MKS Baratron), dew point, Lyotrack (gas plasma spectroscopy), water concentration from tunable diode laser absorption spectroscopy, condenser pressure, pressure rise test (manometric temperature measurement or variations of this method), and product thermocouples. Vials were pulled out from the drying chamber using a sample thief during late primary and early secondary drying to determine percent residual moisture either gravimetrically or by Karl Fischer, and the cake structure was determined visually for melt-back, collapse, and retention of cake structure at the apparent end point of primary drying (i.e., onset, midpoint, and offset). By far, the Pirani is the best choice of the methods tested for evaluation of the end point of primary drying. Also, it is a batch technique, which is cheap, steam sterilizable, and easy to install without requiring any modification to the existing dryer.
Effect of Time on Gypsum-Impression Material Compatibility
NASA Astrophysics Data System (ADS)
Won, John Boram
The purpose of this study was to evaluate the compatibility of dental gypsum with three recently introduced irreversible hydrocolloid (alginate) alternatives. The test materials were Alginot® (Kerr™), Position Penta Quick® (3M ESPE™) and Silgimix ® (Sultan Dental™). The irreversible hydrocolloid impression material, Jeltrate Plus antimicrobial® (Dentsply Caulk™) served as the control.
A Worst-Case Approach for On-Line Flutter Prediction
NASA Technical Reports Server (NTRS)
Lind, Rick C.; Brenner, Martin J.
1998-01-01
Worst-case flutter margins may be computed for a linear model with respect to a set of uncertainty operators using the structured singular value. This paper considers an on-line implementation to compute these robust margins in a flight test program. Uncertainty descriptions are updated at test points to account for unmodeled time-varying dynamics of the airplane by ensuring the robust model is not invalidated by measured flight data. Robust margins computed with respect to this uncertainty remain conservative to the changing dynamics throughout the flight. A simulation clearly demonstrates this method can improve the efficiency of flight testing by accurately predicting the flutter margin to improve safety while reducing the necessary flight time.
2008-05-14
survey rake installed in the test section to measure pitot pressure, static pressure and stagnation point heat transfer in the freestream. From these...on the cone, employing time of arrival pressure transducers to obtain 2"d mode transition frequencies, and making pitot pressure measurements to...these studies have proven to be the most accurate measurement technique in supersonic and hypersonic test facilities, and the small size of the sensing
NASA Technical Reports Server (NTRS)
Dayman, B., Jr.; Fiore, A. W.
1974-01-01
The present work discusses in general terms the various kinds of ground facilities, in particular, wind tunnels, which support aerodynamic testing. Since not all flight parameters can be simulated simultaneously, an important problem consists in matching parameters. It is pointed out that there is a lack of wind tunnels for a complete Reynolds-number simulation. Using a computer to simulate flow fields can result in considerable reduction of wind-tunnel hours required to develop a given flight vehicle.
Noninvasive stress testing - Methodology for elimination of the phonocardiogram
NASA Technical Reports Server (NTRS)
Spodick, D. H.; Lance, V. Q.
1976-01-01
Measurement by systolic time intervals (STI) of cardiac responses requires extremely careful recording during actual stress test performance. Previous work indicated no significant changes in the pulse transmission time (PTT) during exercise and other challenges. Since external STI depend on the carotid pulse offset by the PTT as an aortic curve equivalent, stable PTT implies that timing of the carotid upstroke and the carotid incisura would respectively track the pre-ejection period and the aortic incisura. In ten subjects, STIs were recorded at supine rest, sitting, standing, during prompt and sustained squatting and during isometric and dynamic exercise. The results demonstrated the tracking of both points. Coefficients of correlation and of determination were uniformly high for all challenges except isometric handgrip (IHG). Since left ventricular ejection time is obtained directly from the pulse curve, with the exception of IHG, STI responses during stress testing can be measured without a phonocardiogram.
Genetic algorithms applied to the scheduling of the Hubble Space Telescope
NASA Technical Reports Server (NTRS)
Sponsler, Jeffrey L.
1989-01-01
A prototype system employing a genetic algorithm (GA) has been developed to support the scheduling of the Hubble Space Telescope. A non-standard knowledge structure is used and appropriate genetic operators have been created. Several different crossover styles (random point selection, evolving points, and smart point selection) are tested and the best GA is compared with a neural network (NN) based optimizer. The smart crossover operator produces the best results and the GA system is able to evolve complete schedules using it. The GA is not as time-efficient as the NN system and the NN solutions tend to be better.
Simulation and experiment of a fuzzy logic based MPPT controller for a small wind turbine system
NASA Astrophysics Data System (ADS)
Petrila, Diana; Muntean, Nicolae
2012-09-01
This paper describes the development of a fuzzy logic based maximum power point tracking (MPPT) strategy for a variable speed wind turbine system (VSWT). For this scope, a fuzzy logic controller (FLC) was described, simulated and tested on a real time "hardware in the loop" wind turbine emulator. Simulation and experimental results show that the controller is able to track the maximum power point for various wind conditions and validate the proposed control strategy.
Parallelization of Program to Optimize Simulated Trajectories (POST3D)
NASA Technical Reports Server (NTRS)
Hammond, Dana P.; Korte, John J. (Technical Monitor)
2001-01-01
This paper describes the parallelization of the Program to Optimize Simulated Trajectories (POST3D). POST3D uses a gradient-based optimization algorithm that reaches an optimum design point by moving from one design point to the next. The gradient calculations required to complete the optimization process, dominate the computational time and have been parallelized using a Single Program Multiple Data (SPMD) on a distributed memory NUMA (non-uniform memory access) architecture. The Origin2000 was used for the tests presented.
Glasmacher, S A; Bonongwe, P; Stones, W
2016-03-01
To achieve good outcomes in critically ill obstetric patients, it is necessary to identify organ dysfunction rapidly so that life-saving interventions can be appropriately commenced. However, timely access to clinical chemistry results is problematic, even in referral institutions, in the sub-Saharan African region. Reliable point-of-care tests licensed for clinical use are now available for lactate and creatinine. We aimed to assess whether implementation of point-of-care testing for lactate and creatinine is feasible in the obstetric unit at the Queen Elizabeth Central Hospital (QECH) in Blantyre, Malawi, by obtaining the opinions of clinical staff on the use of these tests in practice. During a two-month evaluation period nurse-midwives, medical interns, clinical officers, registrars, and consultants were given the opportunity to use StatStrip® and StatSensor® (Nova Biomedical, Waltham, USA) devices, for lactate and creatinine estimation, as part of their routine clinical practice in the obstetric unit. They were subsequently asked to complete a short questionnaire. Thirty-seven questionnaires were returned by participants: 22 from nurse-midwives and the remainder from clinicians. The mean satisfaction score for the devices was 7.6/10 amongst clinicians and 8.0/10 amongst nurse-midwives. The majority of participants stated that the obstetric high dependency unit (HDU) was the most suitable location for the devices. For lactate, 31 participants strongly agreed that testing should be continued and 24 strongly agreed that it would influence patient management. For creatinine, 29 strongly agreed that testing should be continued and 28 strongly agreed that it would influence their patient management. Twenty participants strongly agreed that they trust point-of-care devices. Point-of-care clinical chemistry testing was feasible, practical, and well received by staff, and was considered to have a useful role to play in the clinical care of sick obstetric patients at this referral centre.
Arantes, Mavilde; Barbosa, Joselina Maria; Ferreira, Maria Amélia
2017-09-01
General practitioners are responsible for the management of an increasing number of patients with neurological illness, and thus a solid education in neurosciences is a necessary component of their training. This study examines the effects of an intensive clinical neuroanatomy course on twenty general practice residents' perceptions, attitudes, and knowledge. A knowledge test was completed by the participants and by a control group at four different time points. The participants were asked to answer a questionnaire about their reasons for signing up for the course and their attitudes and perceptions toward the course experience. Experimental and control groups demonstrated identical mean baseline test scores. The experimental group significantly increased its test scores (plus 49.0% correct answers, a mean improvement of 120%) relative to controls after the educational intervention. There were no differences among scores from the evaluated time points after the educational intervention in the experimental group. In the control group, there were likewise no significant differences between the four evaluated time points. Most participants indicated that they signed up for the course to update/acquire knowledge and skills in the field of neurosciences, and also because they had difficulty in diagnosing and managing patients with neurological diseases. Participants' attitudes and perceptions toward the course experience were very positive. Most of the participants (n = 17; 85%) rated the course as "extremely useful," and 3 (15%) rated it as "very useful." This study provides evidence demonstrating the potential positive effect of neurosciences education to general practice residents. Anat Sci Educ 10: 465-474. © 2017 American Association of Anatomists. © 2017 American Association of Anatomists.
Economic and Microbiologic Evaluation of Single-Dose Vial Extension for Hazardous Drugs
Rowe, Erinn C.; Savage, Scott W.; Rutala, William A.; Weber, David J.; Gergen-Teague, Maria; Eckel, Stephen F.
2012-01-01
Purpose: The update of US Pharmacopeia Chapter <797> in 2008 included guidelines stating that single-dose vials (SDVs) opened and maintained in an International Organization for Standardization Class 5 environment can be used for up to 6 hours after initial puncture. A study was conducted to evaluate the cost of discarding vials after 6 hours and to further test sterility of vials beyond this time point, subsequently defined as the beyond-use date (BUD). Methods: Financial determination of SDV waste included 2 months of retrospective review of all doses prescribed. Additionally, actual waste log data were collected. Active and control vials (prepared using sterilized trypticase soy broth) were recovered, instead of discarded, at the defined 6-hour BUD. Results: The institution-specific waste of 19 selected SDV medications discarded at 6 hours was calculated at $766,000 annually, and tracking waste logs for these same medications was recorded at $770,000 annually. Microbiologic testing of vial extension beyond 6 hours showed that 11 (1.86%) of 592 samples had one colony-forming unit on one of two plates. Positive plates were negative at subsequent time points, and all positives were single isolates most likely introduced during the plating process. Conclusion: The cost of discarding vials at 6 hours was significant for hazardous medications in a large academic medical center. On the basis of microbiologic data, vial BUD extension demonstrated a contamination frequency of 1.86%, which likely represented exogenous contamination; vial BUD extension for the tested drugs showed no growth at subsequent time points and could provide an annual cost savings of more than $600,000. PMID:23180998
Postural Stability in Cigarette Smokers and During Abstinence from Alcohol
Schmidt, Thomas Paul; Pennington, David Louis; Durazzo, Timothy Craig; Meyerhoff, Dieter Johannes
2014-01-01
Background Static postural instability is common in alcohol dependent individuals (ALC). Chronic alcohol consumption has deleterious effects on the neural and perceptual systems subserving postural stability. However, little is known about the effects of chronic cigarette smoking on postural stability and its changes during abstinence from alcohol. Methods A modified Fregly ataxia battery was administered to a total of 115 smoking (sALC) and non-smoking ALC (nsALC) and to 74 smoking (sCON) and non-smoking light/non-drinking controls (nsCON). Subgroups of abstinent ALC were assessed at 3 time points (approximately 1 week, 5 weeks, 34 weeks of abstinence from alcohol); a subset of nsCON was re-tested at 40 weeks. We tested if cigarette smoking affects postural stability in CON and in ALC during extended abstinence from alcohol, and we used linear mixed effects modeling to measure change across time points within ALC. Results Chronic smoking was associated with reduced performance on the Sharpened Romberg eyes-closed task in abstinent ALC at all three time points and in CON. The test performance of nsALC increased significantly between 1 and 32 weeks of abstinence, whereas the corresponding increases for sALC between 1 and 35 weeks was non-significant. With long-term abstinence from alcohol, nsALC recovered into the range of nsCON and sALC recovered into the range of sCON. Static postural stability decreased with age and correlated with smoking variables but not with drinking measures. Conclusions Chronic smoking was associated with reduced static postural stability with eyes closed and with lower increases of postural stability during abstinence from alcohol. Smoking cessation in alcohol dependence treatment may facilitate recovery from static postural instability during abstinence. PMID:24721012
Research on stratified evolution of composite materials under four-point bending loading
NASA Astrophysics Data System (ADS)
Hao, M. J.; You, Q. J.; Zheng, J. C.; Yue, Z.; Xie, Z. P.
2017-12-01
In order to explore the effect of stratified evolution and delamination on the load capacity and service life of the composite materials under the four-point bending loading, the artificial tectonic defects of the different positions were set up. The four-point bending test was carried out, and the whole process was recorded by acoustic emission, and the damage degree of the composite layer was judged by the impact accumulation of the specimen - time-amplitude history chart, load-time-relative energy history chart, acoustic emission impact signal positioning map. The results show that the stratified defects near the surface of the specimen accelerate the process of material failure and expansion. The location of the delamination defects changes the bending performance of the composites to a great extent. The closer the stratification defects are to the surface of the specimen, the greater the damage, the worse the service capacity of the specimen.
Single-shot polarimetry imaging of multicore fiber.
Sivankutty, Siddharth; Andresen, Esben Ravn; Bouwmans, Géraud; Brown, Thomas G; Alonso, Miguel A; Rigneault, Hervé
2016-05-01
We report an experimental test of single-shot polarimetry applied to the problem of real-time monitoring of the output polarization states in each core within a multicore fiber bundle. The technique uses a stress-engineered optical element, together with an analyzer, and provides a point spread function whose shape unambiguously reveals the polarization state of a point source. We implement this technique to monitor, simultaneously and in real time, the output polarization states of up to 180 single-mode fiber cores in both conventional and polarization-maintaining fiber bundles. We demonstrate also that the technique can be used to fully characterize the polarization properties of each individual fiber core, including eigen-polarization states, phase delay, and diattenuation.
a Method of Time-Series Change Detection Using Full Polsar Images from Different Sensors
NASA Astrophysics Data System (ADS)
Liu, W.; Yang, J.; Zhao, J.; Shi, H.; Yang, L.
2018-04-01
Most of the existing change detection methods using full polarimetric synthetic aperture radar (PolSAR) are limited to detecting change between two points in time. In this paper, a novel method was proposed to detect the change based on time-series data from different sensors. Firstly, the overall difference image of a time-series PolSAR was calculated by ominous statistic test. Secondly, difference images between any two images in different times ware acquired by Rj statistic test. Generalized Gaussian mixture model (GGMM) was used to obtain time-series change detection maps in the last step for the proposed method. To verify the effectiveness of the proposed method, we carried out the experiment of change detection by using the time-series PolSAR images acquired by Radarsat-2 and Gaofen-3 over the city of Wuhan, in China. Results show that the proposed method can detect the time-series change from different sensors.
Hyle, Emily P; Jani, Ilesh V; Lehe, Jonathan; Su, Amanda E; Wood, Robin; Quevedo, Jorge; Losina, Elena; Bassett, Ingrid V; Pei, Pamela P; Paltiel, A David; Resch, Stephen; Freedberg, Kenneth A; Peter, Trevor; Walensky, Rochelle P
2014-09-01
Point-of-care CD4 tests at HIV diagnosis could improve linkage to care in resource-limited settings. Our objective is to evaluate the clinical and economic impact of point-of-care CD4 tests compared to laboratory-based tests in Mozambique. We use a validated model of HIV testing, linkage, and treatment (CEPAC-International) to examine two strategies of immunological staging in Mozambique: (1) laboratory-based CD4 testing (LAB-CD4) and (2) point-of-care CD4 testing (POC-CD4). Model outcomes include 5-y survival, life expectancy, lifetime costs, and incremental cost-effectiveness ratios (ICERs). Input parameters include linkage to care (LAB-CD4, 34%; POC-CD4, 61%), probability of correctly detecting antiretroviral therapy (ART) eligibility (sensitivity: LAB-CD4, 100%; POC-CD4, 90%) or ART ineligibility (specificity: LAB-CD4, 100%; POC-CD4, 85%), and test cost (LAB-CD4, US$10; POC-CD4, US$24). In sensitivity analyses, we vary POC-CD4-specific parameters, as well as cohort and setting parameters to reflect a range of scenarios in sub-Saharan Africa. We consider ICERs less than three times the per capita gross domestic product in Mozambique (US$570) to be cost-effective, and ICERs less than one times the per capita gross domestic product in Mozambique to be very cost-effective. Projected 5-y survival in HIV-infected persons with LAB-CD4 is 60.9% (95% CI, 60.9%-61.0%), increasing to 65.0% (95% CI, 64.9%-65.1%) with POC-CD4. Discounted life expectancy and per person lifetime costs with LAB-CD4 are 9.6 y (95% CI, 9.6-9.6 y) and US$2,440 (95% CI, US$2,440-US$2,450) and increase with POC-CD4 to 10.3 y (95% CI, 10.3-10.3 y) and US$2,800 (95% CI, US$2,790-US$2,800); the ICER of POC-CD4 compared to LAB-CD4 is US$500/year of life saved (YLS) (95% CI, US$480-US$520/YLS). POC-CD4 improves clinical outcomes and remains near the very cost-effective threshold in sensitivity analyses, even if point-of-care CD4 tests have lower sensitivity/specificity and higher cost than published values. In other resource-limited settings with fewer opportunities to access care, POC-CD4 has a greater impact on clinical outcomes and remains cost-effective compared to LAB-CD4. Limitations of the analysis include the uncertainty around input parameters, which is examined in sensitivity analyses. The potential added benefits due to decreased transmission are excluded; their inclusion would likely further increase the value of POC-CD4 compared to LAB-CD4. POC-CD4 at the time of HIV diagnosis could improve survival and be cost-effective compared to LAB-CD4 in Mozambique, if it improves linkage to care. POC-CD4 could have the greatest impact on mortality in settings where resources for HIV testing and linkage are most limited. Please see later in the article for the Editors' Summary.
2010-01-01
Background The objective of this study was to investigate whether the 13C-phenylalanine breath test could be useful for the evaluation of hepatic function in elderly volunteers and patients with chronic hepatitis B and liver cirrhosis. Methods L-[1-13C] phenylalanine was administered orally at a dose of 100 mg to 55 elderly patients with liver cirrhosis, 30 patients with chronic hepatitis B and 38 elderly healthy subjects. The breath test was performed at 8 different time points (0, 10, 20, 30, 45, 60, 90, 120 min) to obtain the values of Delta over baseline, percentage 13CO2 exhalation rate and cumulative excretion (Cum). The relationships of the cumulative excretion with the 13C-%dose/h and blood biochemical parameters were investigated. Results The 13C-%dose/h at 20 min and 30 min combined with the cumulative excretion at 60 min and 120 min correlated with hepatic function tests, serum albumin, hemoglobin, platelet and Child-Pugh score. Prothrombin time, total and direct bilirubin were significantly increased, while serum albumin, hemoglobin and platelet, the cumulative excretion at 60 min and 120 min values decreased by degrees of intensity of the disease in Child-Pugh A, B, and C patients (P < 0.01). Conclusions The 13C-phenylalanine breath test can be used as a non-invasive assay to evaluate hepatic function in elderly patients with liver cirrhosis. The 13C-%dose/h at 20 min, at 30 min and cumulative excretion at 60 min may be the key value for determination at a single time-point. 13C-phenylalanine breath test is safe and helpful in distinguishing different stages of hepatic dysfunction for elderly cirrhosis patients. PMID:20459849
NASA Astrophysics Data System (ADS)
Newcomb, D. E.; McKeen, R. G.
1983-12-01
This report documents over 2 years of research efforts to characterize asphalt-rubber mixtures to be used in Stress-Absorbing Membrane Interlayers (SAMI). The purpose of these SAMIs is to retard or prevent reflection cracking in asphalt-concrete overlays. Several laboratory experiments and one field trial were conducted to define significant test methods and parameters for incorporation into construction design and specification documents. Test methods used in this study included a modified softening point test, force-ductility, and Schweyer viscosity. Variables investigated included (1) Laboratory-mixing temperature; (2) Rubber type; (3) Laboratory storage time; (4) Laboratory storage condition; (5) Laboratory batch replication; (6) Laboratory mixing time; (7) Field mixing time; (8) Laboratory test temperature; (9) Force-Ductility elongation rates; and (10) Asphalt grade. It was found that mixing temperature, mixing time, rubber type, and asphalt grade all have significant effects upon the behavior of asphalt-rubber mixtures. Significant variability was also noticed in different laboratory batch replications. Varying laboratory test temperature and force-ductility elongation rate revealed further differences in asphalt-rubber mixtures.
Aerobic Capacity is Related to Repeated Sprint Ability with Sprint Distances Less Than 40 Meters
SANDERS, GABRIEL J.; TURNER, ZACHARY; BOOS, BRIAN; PEACOCK, COREY A.; PEVELER, WILLARD; LIPPING, ALAR
2017-01-01
Research is inconclusive regarding the association between aerobic fitness (objectively measured VO2max) and repeated sprint performance when the sprints are less than 40 meters. Soccer athletes must be able to repeat sprints without significant decreases in speed and strength and conditioning coaches need to better understand if aerobic fitness is related to repeated sprint ability (RSA). Twenty (10 male, 10 female) Division I soccer athletes first completed a graded maximal treadmill test to measure VO2max. Then on a separate day, athletes completed the RSA test. The RSA test consisted of 10, 30-meter sprints which athletes repeated every 30 seconds. There were significant negative correlations (r ≤ −0.69, P < 0.001) between VO2max and all 10-sprint times and average sprint time. More aerobically fit Division I soccer athletes were faster at all time points during the RSA test. Aerobic fitness is associated with faster sprint times during a more anaerobic RSA test when sprint distances are less than 40 meters. PMID:28344734
Stability and Change in Interests: A Longitudinal Study of Adolescents from Grades 8 through 12
ERIC Educational Resources Information Center
Tracey, Terence J. G.; Robbins, Steven B.; Hofsess, Christy D.
2005-01-01
The pattern of RIASEC interests and academic skills were assessed longitudinally from a large-scale national database at three time points: eight grade, 10th grade, and 12th grade. Validation and cross-validation samples of 1000 males and 1000 females in each set were used to test the pattern of these scores over time relative to mean changes,…
A synopsis of test results and knowledge gained from the Phase-0 CSI evolutionary model
NASA Technical Reports Server (NTRS)
Belvin, W. Keith; Elliott, Kenny B.; Horta, Lucas G.
1993-01-01
The Phase-0 CSI Evolutionary Model (CEM) is a testbed for the study of space platform global line-of-sight (LOS) pointing. Now that the tests have been completed, a summary of hardware and closed-loop test experiences is necessary to insure a timely dissemination of the knowledge gained. The testbed is described and modeling experiences are presented followed by a summary of the research performed by various investigators. Some early lessons on implementing the closed-loop controllers are described with particular emphasis on real-time computing requirements. A summary of closed-loop studies and a synopsis of test results are presented. Plans for evolving the CEM from phase 0 to phases 1 and 2 are also described. Subsequently, a summary of knowledge gained from the design and testing of the Phase-0 CEM is made.
Mainhagu, Jon; Morrison, C.; Truex, Michael J.; ...
2014-08-05
A method termed vapor-phase tomography has recently been proposed to characterize the distribution of volatile organic contaminant mass in vadose-zone source areas, and to measure associated three-dimensional distributions of local contaminant mass discharge. The method is based on measuring the spatial variability of vapor flux, and thus inherent to its effectiveness is the premise that the magnitudes and temporal variability of vapor concentrations measured at different monitoring points within the interrogated area will be a function of the geospatial positions of the points relative to the source location. A series of flow-cell experiments was conducted to evaluate this premise. Amore » well-defined source zone was created by injection and extraction of a non-reactive gas (SF6). Spatial and temporal concentration distributions obtained from the tests were compared to simulations produced with a mathematical model describing advective and diffusive transport. Tests were conducted to characterize both areal and vertical components of the application. Decreases in concentration over time were observed for monitoring points located on the opposite side of the source zone from the local–extraction point, whereas increases were observed for monitoring points located between the local–extraction point and the source zone. We found that the results illustrate that comparison of temporal concentration profiles obtained at various monitoring points gives a general indication of the source location with respect to the extraction and monitoring points.« less
Alkhawaldeh, Khaled; Biersack, Hans-J; Henke, Anna; Ezziddin, Samer
2011-06-01
The aim of this study was to assess the utility of dual-time-point F-18 fluorodeoxyglucose positron emission tomography (F-18 FDG PET) in differentiating benign from malignant pleural disease, in patients with non-small-cell lung cancer. A total of 61 patients with non-small-cell lung cancer and pleural effusion were included in this retrospective study. All patients had whole-body FDG PET/CT imaging at 60 ± 10 minutes post-FDG injection, whereas 31 patients had second-time delayed imaging repeated at 90 ± 10 minutes for the chest. Maximum standardized uptake values (SUV(max)) and the average percent change in SUV(max) (%SUV) between time point 1 and time point 2 were calculated. Malignancy was defined using the following criteria: (1) visual assessment using 3-points grading scale; (2) SUV(max) ≥2.4; (3) %SUV ≥ +9; and (4) SUV(max) ≥2.4 and/or %SUV ≥ +9. Analysis of variance test and receiver operating characteristic analysis were used in statistical analysis. P < 0.05 was considered significant. Follow-up revealed 29 patient with malignant pleural disease and 31 patients with benign pleural effusion. The average SUV(max) in malignant effusions was 6.5 ± 4 versus 2.2 ± 0.9 in benign effusions (P < 0.0001). The average %SUV in malignant effusions was +13 ± 10 versus -8 ± 11 in benign effusions (P < 0.0004). Sensitivity, specificity, and accuracy for the 5 criteria were as follows: (1) 86%, 72%, and 79%; (2) 93%, 72%, and 82%; (3) 67%, 94%, and 81%; (4) 100%, 94%, and 97%. Dual-time-point F-18 FDG PET can improve the diagnostic accuracy in differentiating benign from malignant pleural disease, with high sensitivity and good specificity.
Validation of a virtual reality-based simulator for shoulder arthroscopy.
Rahm, Stefan; Germann, Marco; Hingsammer, Andreas; Wieser, Karl; Gerber, Christian
2016-05-01
This study was to determine face and construct validity of a new virtual reality-based shoulder arthroscopy simulator which uses passive haptic feedback. Fifty-one participants including 25 novices (<20 shoulder arthroscopies) and 26 experts (>100 shoulder arthroscopies) completed two tests: for assessment of face validity, a questionnaire was filled out concerning quality of simulated reality and training potential using a 7-point Likert scale (range 1-7). Construct validity was tested by comparing simulator metrics (operation time in seconds, camera and grasper pathway in centimetre and grasper openings) between novices and experts test results. Overall simulated reality was rated high with a median value of 5.5 (range 2.8-7) points. Training capacity scored a median value of 5.8 (range 3-7) points. Experts were significantly faster in the diagnostic test with a median of 91 (range 37-208) s than novices with 1177 (range 81-383) s (p < 0.0001) and in the therapeutic test 102 (range 58-283) s versus 229 (range 114-399) s (p < 0.0001). Similar results were seen in the other metric values except in the camera pathway in the therapeutic test. The tested simulator achieved high scores in terms of realism and training capability. It reliably discriminated between novices and experts. Further improvements of the simulator, especially in the field of therapeutic arthroscopy, might improve its value as training and assessment tool for shoulder arthroscopy skills. II.
NASA Astrophysics Data System (ADS)
Chandniha, Surendra Kumar; Meshram, Sarita Gajbhiye; Adamowski, Jan Franklin; Meshram, Chandrashekhar
2017-10-01
Jharkhand is one of the eastern states of India which has an agriculture-based economy. Uncertain and erratic distribution of precipitation as well as a lack of state water resources planning is the major limitation to crop growth in the region. In this study, the spatial and temporal variability in precipitation in the state was examined using a monthly precipitation time series of 111 years (1901-2011) from 18 meteorological stations. Autocorrelation and Mann-Kendall/modified Mann-Kendall tests were utilized to detect possible trends, and the Theil and Sen slope estimator test was used to determine the magnitude of change over the entire time series. The most probable change year (change point) was detected using the Pettitt-Mann-Whitney test, and the entire time series was sub-divided into two parts: before and after the change point. Arc-Map 9.3 software was utilized to assess the spatial patterns of the trends over the entire state. Annual precipitation exhibited a decreasing trend in 5 out of 18 stations during the whole period. For annual, monsoon and winter periods of precipitation, the slope test indicated a decreasing trend for all stations during 1901-2011. The highest variability was observed in post-monsoon precipitation (77.87 %) and the lowest variability was observed in the annual series (15.76 %) over the 111 years. An increasing trend in precipitation in the state was found during the period 1901-1949, which was reversed during the subsequent period (1950-2011).
Cole, Lynette K; Luu, Dao H; Rajala-Schultz, Paivi J; Meadows, Cheyney; Torres, Audrey H
2007-04-01
The purpose of this study was to evaluate the in vitro activity of an ear rinse containing tromethamine, EDTA, benzyl alcohol and 0.1% ketoconazole in purified water on Malassezia organisms from dogs with otitis externa. Malassezia organisms were collected from ear swab samples from the external ear canal of 19 dogs with otitis externa plus one control strain of Malassezia pachydermatis. Three test solutions were evaluated: ER (EDTA, tromethamine, benzyl alcohol), ER + keto (EDTA, tromethamine, benzyl alcohol, ketoconazole), and H2O (purified water). Ten-millilitre aliquots of each test solution was transferred into 20 tubes and inoculated with one of the isolates (1 tube per isolate: 19 clinical and 1 control strain). Samples were retrieved from each tube at five time points (0, 15, 30, 45 and 60 min), transferred to Petri dishes, mixed with Sabouraud dextrose agar supplemented with 0.5% Tween 80 and incubated. Following incubation, the plates were examined for growth and colonies counted as colony-forming units per millilitre. The data were analysed using a repeated measures analysis, with pair-wise comparisons of solution-time combinations. There was a significant reduction in Malassezia growth in ER + keto at all time points (P < 0.0001) compared to time zero. Neither ER nor H2O had any effect on the growth of Malassezia. ER + keto was significantly more effective in reducing Malassezia growth (P < 0.0001) at all time points compared to both ER and H2O. ER + keto may be useful in the treatment of Malassezia otitis externa. Future studies should be performed to evaluate the in vivo efficacy of ER + keto as treatment for otic infections caused by Malassezia.
Cardot, J-M; Roudier, B; Schütz, H
2017-07-01
The f 2 test is generally used for comparing dissolution profiles. In cases of high variability, the f 2 test is not applicable, and the Multivariate Statistical Distance (MSD) test is frequently proposed as an alternative by the FDA and EMA. The guidelines provide only general recommendations. MSD tests can be performed either on raw data with or without time as a variable or on parameters of models. In addition, data can be limited-as in the case of the f 2 test-to dissolutions of up to 85% or to all available data. In the context of the present paper, the recommended calculation included all raw dissolution data up to the first point greater than 85% as a variable-without the various times as parameters. The proposed MSD overcomes several drawbacks found in other methods.
Pursuing optimal electric machines transient diagnosis: The adaptive slope transform
NASA Astrophysics Data System (ADS)
Pons-Llinares, Joan; Riera-Guasp, Martín; Antonino-Daviu, Jose A.; Habetler, Thomas G.
2016-12-01
The aim of this paper is to introduce a new linear time-frequency transform to improve the detection of fault components in electric machines transient currents. Linear transforms are analysed from the perspective of the atoms used. A criterion to select the atoms at every point of the time-frequency plane is proposed, taking into account the characteristics of the searched component at each point. This criterion leads to the definition of the Adaptive Slope Transform, which enables a complete and optimal capture of the different components evolutions in a transient current. A comparison with conventional linear transforms (Short-Time Fourier Transform and Wavelet Transform) is carried out, showing their inherent limitations. The approach is tested with laboratory and field motors, and the Lower Sideband Harmonic is captured for the first time during an induction motor startup and subsequent load oscillations, accurately tracking its evolution.
Kearney, Paddy; Stafford, Bob; Gormley, Gerard J.; Crockard, Martin A.; Gilpin, Deirdre F.
2018-01-01
Background Urinary Tract Infections (UTIs) are common bacterial infections, second only to respiratory tract infections and particularly prevalent within primary care. Conventional detection of UTIs is culture, however, return of results can take between 24 and 72 hours. The introduction of a point of care (POC) test would allow for more timely identification of UTIs, facilitating improved, targeted treatment. This study aimed to obtain consensus on the criteria required for a POC UTI test, to meet patient need within primary care. Methods Criteria for consideration were compiled by the research team. These criteria were validated through a two-round Delphi process, utilising an expert panel of healthcare professionals from across Europe and United States of America. Using web-based questionnaires, panellists recorded their level of agreement with each criterion based on a 5-point Likert Scale, with space for comments. Using median response, interquartile range and comments provided, criteria were accepted/rejected/revised depending on pre-agreed cut-off scores. Results The first round questionnaire presented thirty-three criteria to the panel, of which 22 were accepted. Consensus was not achieved for the remaining 11 criteria. Following response review, one criterion was removed, while after revision, the remaining 10 criteria entered the second round. Of these, four were subsequently accepted, resulting in 26 criteria considered appropriate for a POC test to detect urinary infections. Conclusion This study generated an approved set of criteria for a POC test to detect urinary infections. Criteria acceptance and comments provided by the healthcare professionals also supports the development of a multiplex point of care UTI test. PMID:29879161
Does Cognitive Ability Predict Mortality in the Ninth Decade? The Lothian Birth Cohort 1921
ERIC Educational Resources Information Center
Murray, Catherine; Pattie, Alison; Starr, John M.; Deary, Ian J.
2012-01-01
To test whether cognitive ability predicts survival from age 79 to 89 years data were collected from 543 (230 male) participants who entered the study at a mean age of 79.1 years. Most had taken the Moray House Test of general intelligence (MHT) when aged 11 and 79 years from which, in addition to intelligence measures at these two time points,…
ERIC Educational Resources Information Center
Wray, Kraig; Lai, Cheng-Fei; Sáez, Leilani; Alonzo, Julie; Tindal, Gerald
2013-01-01
We report the results of an alternate form reliability and criterion validity study of kindergarten and grade 1 (N = 84-199) reading measures from the easyCBM© assessment system and Stanford Early School Achievement Test/Stanford Achievement Test, 10th edition (SESAT/SAT-10) across 5 time points. The alternate form reliabilities ranged from…
D-RATS 2011: RAFT Protocol Overview
NASA Technical Reports Server (NTRS)
Utz, Hans
2011-01-01
A brief overview presentation on the protocol used during the D-RATS2011 field test for file transfer from the field-test robots at Black Point Lava Flow AZ to Johnson Space Center, Houston TX over a simulated time-delay. The file transfer actually uses a commercial implementation of an open communications standard. The focus of the work lies on how to make the state of the distributed system observable.
A photoelectric amplifier as a dye detector
Ebel, Wesley J.
1962-01-01
A dye detector, based on a modified photoelectric amplifier, has been planned, built, and tested. It was designed to record automatically the time of arrival of fluorescein dye at predetermined points in a stream system. Laboratory tests and stream trials proved the instrument to be efficient. Small changes in color can be detected in turbid or clear water. The unit has been used successfully for timing intervals of more than 17 hours; significant savings of time and manpower have resulted. Replacement of the clock, included in the original device, with a recording milliammeter increases the efficiency of the unit by contin,!ously recording changes in turbidity. The addition of this component would increase the cost from $75 to approximately $105.
Enhancing Early Childhood Mental Health Primary Care Services: Evaluation of MA Project LAUNCH.
Molnar, Beth E; Lees, Kristin E; Roper, Kate; Byars, Natasha; Méndez-Peñate, Larisa; Moulin, Christy; McMullen, William; Wolfe, Jessica; Allen, Deborah
2018-06-16
Objectives The purpose of this study was to evaluate the efficacy of an innovative early childhood mental health intervention, Massachusetts Project LAUNCH. Early childhood mental health clinicians and family partners (paraprofessionals with lived experience) were embedded within community pediatric medical homes. Methods A longitudinal study design was used to test the hypotheses that (1) children who received services would experience decreased social, emotional and behavioral problems over time and (2) caregivers' stress and depressive symptoms would decrease over time. Families who were enrolled in services and who consented to participate in the evaluation study were included in analyses (N = 225). Individual growth models were used to test longitudinal effects among MA LAUNCH participants (children and caregivers) over three time points using screening tools. Results Analyses showed that LAUNCH children who scored in age-specific clinically significant ranges of social, emotional and behavioral problems at Time 1 scored in the normal range on average by Time 3. Caregivers' stress and depressive symptoms also declined across the three time points. Results support hypotheses that the LAUNCH intervention improved social and emotional health for children and caregivers. Conclusions for Practice This study led to sustainability efforts, an expansion of the model to three additional communities across the state and development of an online toolkit for other communities interested in implementation.
NASA Technical Reports Server (NTRS)
Morelli, Eugene A.
1996-01-01
Flight test maneuvers are specified for the F-18 High Alpha Research Vehicle (HARV). The maneuvers were designed for closed loop parameter identification purposes, specifically for longitudinal and lateral linear model parameter estimation at 5, 20, 30, 45, and 60 degrees angle of attack, using the NASA 1A control law. Each maneuver is to be realized by the pilot applying square wave inputs to specific pilot station controls. Maneuver descriptions and complete specifications of the time/amplitude points defining each input are included, along with plots of the input time histories.
Detection of longitudinal visual field progression in glaucoma using machine learning.
Yousefi, Siamak; Kiwaki, Taichi; Zheng, Yuhui; Suigara, Hiroki; Asaoka, Ryo; Murata, Hiroshi; Lemij, Hans; Yamanishi, Kenji
2018-06-16
Global indices of standard automated perimerty are insensitive to localized losses, while point-wise indices are sensitive but highly variable. Region-wise indices sit in between. This study introduces a machine-learning-based index for glaucoma progression detection that outperforms global, region-wise, and point-wise indices. Development and comparison of a prognostic index. Visual fields from 2085 eyes of 1214 subjects were used to identify glaucoma progression patterns using machine learning. Visual fields from 133 eyes of 71 glaucoma patients were collected 10 times over 10 weeks to provide a no-change, test-retest dataset. The parameters of all methods were identified using visual field sequences in the test-retest dataset to meet fixed 95% specificity. An independent dataset of 270 eyes of 136 glaucoma patients and survival analysis were utilized to compare methods. The time to detect progression in 25% of the eyes in the longitudinal dataset using global mean deviation (MD) was 5.2 years (95% confidence interval, 4.1 - 6.5 years); 4.5 years (4.0 - 5.5) using region-wise, 3.9 years (3.5 - 4.6) using point-wise, and 3.5 years (3.1 - 4.0) using machine learning analysis. The time until 25% of eyes showed subsequently confirmed progression after two additional visits were included were 6.6 years (5.6 - 7.4 years), 5.7 years (4.8 - 6.7), 5.6 years (4.7 - 6.5), and 5.1 years (4.5 - 6.0) for global, region-wise, point-wise, and machine learning analyses, respectively. Machine learning analysis detects progressing eyes earlier than other methods consistently, with or without confirmation visits. In particular, machine learning detects more slowly progressing eyes than other methods. Copyright © 2018 Elsevier Inc. All rights reserved.
Predicting fatty acid profiles in blood based on food intake and the FADS1 rs174546 SNP.
Hallmann, Jacqueline; Kolossa, Silvia; Gedrich, Kurt; Celis-Morales, Carlos; Forster, Hannah; O'Donovan, Clare B; Woolhead, Clara; Macready, Anna L; Fallaize, Rosalind; Marsaux, Cyril F M; Lambrinou, Christina-Paulina; Mavrogianni, Christina; Moschonis, George; Navas-Carretero, Santiago; San-Cristobal, Rodrigo; Godlewska, Magdalena; Surwiłło, Agnieszka; Mathers, John C; Gibney, Eileen R; Brennan, Lorraine; Walsh, Marianne C; Lovegrove, Julie A; Saris, Wim H M; Manios, Yannis; Martinez, Jose Alfredo; Traczyk, Iwona; Gibney, Michael J; Daniel, Hannelore
2015-12-01
A high intake of n-3 PUFA provides health benefits via changes in the n-6/n-3 ratio in blood. In addition to such dietary PUFAs, variants in the fatty acid desaturase 1 (FADS1) gene are also associated with altered PUFA profiles. We used mathematical modeling to predict levels of PUFA in whole blood, based on multiple hypothesis testing and bootstrapped LASSO selected food items, anthropometric and lifestyle factors, and the rs174546 genotypes in FADS1 from 1607 participants (Food4Me Study). The models were developed using data from the first reported time point (training set) and their predictive power was evaluated using data from the last reported time point (test set). Among other food items, fish, pizza, chicken, and cereals were identified as being associated with the PUFA profiles. Using these food items and the rs174546 genotypes as predictors, models explained 26-43% of the variability in PUFA concentrations in the training set and 22-33% in the test set. Selecting food items using multiple hypothesis testing is a valuable contribution to determine predictors, as our models' predictive power is higher compared to analogue studies. As unique feature, we additionally confirmed our models' power based on a test set. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Joiner, Logan C; Tynes, Clay; Arnold, John; Miller, Rachel R; Gorman, Greg
2018-04-01
Purpose: The purpose of this study was to determine the physical compatibility of micafungin with commonly used concentrations of sodium bicarbonate hydration fluids administered via a Y-site connected to a central venous catheter (Y-site/CVC). Methods: Micafungin sodium (evaluated concentration of 1.5 mg/mL) was combined in a 3:1 (vehicle:drug) ratio with the following commonly used hydration vehicles: 40 mEq/L sodium bicarbonate in 5% dextrose in water with ¼ normal saline (40SB-D5W-1/4NS), 75 mEq/L sodium bicarbonate in D5W (75SB-D5W), and 154 mEq/L sodium bicarbonate in D5W (154SB-D5W). A 3:1 ratio was used based on the flow rates (typically 125 mL/m 2 /h for bicarbonate-containing vehicles and 50 mL/h for micafungin) of the corresponding solutions in a clinical setting. Visual observations recorded to determine physical compatibility included visual inspection against different backgrounds (unaided, black, and white). Other physical observations were as follows: odor, evolution of gas, pH, and turbidity immediately recorded after mixing and at specified time points up to 2 hours. Evaluations at each time point were compared against baseline observation values at Time 0. Results: All combinations tested were found to be compatible up to 2 hours. Time points beyond 2 hours cannot be safely verified as compatible. Conclusion: Micafungin may be administered safely using a Y-site/CVC delivery system with all the vehicles tested in this study.
Kolliakou, A; Castle, D; Sallis, H; Joseph, C; O'Connor, J; Wiffen, B; Gayer-Anderson, C; McQueen, G; Taylor, H; Bonaccorso, S; Gaughran, F; Smith, S; Greenwood, K; Murray, R M; Di Forti, M; Atakan, Z; Ismail, K
2015-01-01
Why patients with psychosis use cannabis remains debated. The self-medication hypothesis has received some support but other evidence points towards an alleviation of dysphoria model. This study investigated the reasons for cannabis use in first-episode psychosis (FEP) and whether strength in their endorsement changed over time. FEP inpatients and outpatients at the South London and Maudsley, Oxleas and Sussex NHS Trusts UK, who used cannabis, rated their motives at baseline (n=69), 3 months (n=29) and 12 months (n=36). A random intercept model was used to test the change in strength of endorsement over the 12 months. Paired-sample t-tests assessed the differences in mean scores between the five subscales on the Reasons for Use Scale (enhancement, social motive, coping with unpleasant affect, conformity and acceptance and relief of positive symptoms and side effects), at each time-point. Time had a significant effect on scores when controlling for reason; average scores on each subscale were higher at baseline than at 3 months and 12 months. At each time-point, patients endorsed 'enhancement' followed by 'coping with unpleasant affect' and 'social motive' more highly for their cannabis use than any other reason. 'Conformity and acceptance' followed closely. 'Relief of positive symptoms and side effects' was the least endorsed motive. Patients endorsed their reasons for use at 3 months and 12 months less strongly than at baseline. Little support for the self-medication or alleviation of dysphoria models was found. Rather, patients rated 'enhancement' most highly for their cannabis use. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
A point implicit time integration technique for slow transient flow problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kadioglu, Samet Y.; Berry, Ray A.; Martineau, Richard C.
2015-05-01
We introduce a point implicit time integration technique for slow transient flow problems. The method treats the solution variables of interest (that can be located at cell centers, cell edges, or cell nodes) implicitly and the rest of the information related to same or other variables are handled explicitly. The method does not require implicit iteration; instead it time advances the solutions in a similar spirit to explicit methods, except it involves a few additional function(s) evaluation steps. Moreover, the method is unconditionally stable, as a fully implicit method would be. This new approach exhibits the simplicity of implementation ofmore » explicit methods and the stability of implicit methods. It is specifically designed for slow transient flow problems of long duration wherein one would like to perform time integrations with very large time steps. Because the method can be time inaccurate for fast transient problems, particularly with larger time steps, an appropriate solution strategy for a problem that evolves from a fast to a slow transient would be to integrate the fast transient with an explicit or semi-implicit technique and then switch to this point implicit method as soon as the time variation slows sufficiently. We have solved several test problems that result from scalar or systems of flow equations. Our findings indicate the new method can integrate slow transient problems very efficiently; and its implementation is very robust.« less
No evidence of critical slowing down in two endangered Hawaiian honeycreepers
Camp, Richard J.; Reed, J. Michael
2017-01-01
There is debate about the current population trends and predicted short-term fates of the endangered forest birds, Hawai`i Creeper (Loxops mana) and Hawai`i `Ākepa (L. coccineus). Using long-term population size estimates, some studies report forest bird populations as stable or increasing, while other studies report signs of population decline or impending extinction associated with introduced Japanese White-eye (Zosterops japonicus) increase. Reliable predictors of impending population collapse, well before the collapse begins, have been reported in simulations and microcosm experiments. In these studies, statistical indicators of critical slowing down, a phenomenon characterized by longer recovery rates after population size perturbation, are reported to be early warning signals of an impending regime shift observable prior to the tipping point. While the conservation applications of these metrics are commonly discussed, early warning signal detection methods are rarely applied to population size data from natural populations, so their efficacy and utility in species management remain unclear. We evaluated two time series of state-space abundance estimates (1987–2012) from Hakalau Forest National Wildlife Refuge, Hawai`i to test for evidence of early warning signals of impending population collapse for the Hawai`i Creeper and Hawai`i `Ākepa. We looked for signals throughout the time series, and prior to 2000, when white-eye abundance began increasing. We found no evidence for either species of increasing variance, autocorrelation, or skewness, which are commonly reported early warning signals. We calculated linear rather than ordinary skewness because the latter is biased, particularly for small sample sizes. Furthermore, we identified break-points in trends over time for both endangered species, indicating shifts in slopes away from strongly increasing trends, but they were only weakly supported by Bayesian change-point analyses (i.e., no step-wise changes in abundance). The break-point and change-point test results, in addition to the early warning signal analyses, support that the two populations do not appear to show signs of critical slowing down or decline. PMID:29131835
No evidence of critical slowing down in two endangered Hawaiian honeycreepers
Rozek, Jessica C.; Camp, Richard J.; Reed, J. Michael
2017-01-01
There is debate about the current population trends and predicted short-term fates of the endangered forest birds, Hawai`i Creeper (Loxops mana) and Hawai`i `Ākepa (L. coccineus). Using long-term population size estimates, some studies report forest bird populations as stable or increasing, while other studies report signs of population decline or impending extinction associated with introduced Japanese White-eye (Zosterops japonicus) increase. Reliable predictors of impending population collapse, well before the collapse begins, have been reported in simulations and microcosm experiments. In these studies, statistical indicators of critical slowing down, a phenomenon characterized by longer recovery rates after population size perturbation, are reported to be early warning signals of an impending regime shift observable prior to the tipping point. While the conservation applications of these metrics are commonly discussed, early warning signal detection methods are rarely applied to population size data from natural populations, so their efficacy and utility in species management remain unclear. We evaluated two time series of state-space abundance estimates (1987–2012) from Hakalau Forest National Wildlife Refuge, Hawai`i to test for evidence of early warning signals of impending population collapse for the Hawai`i Creeper and Hawai`i `Ākepa. We looked for signals throughout the time series, and prior to 2000, when white-eye abundance began increasing. We found no evidence for either species of increasing variance, autocorrelation, or skewness, which are commonly reported early warning signals. We calculated linear rather than ordinary skewness because the latter is biased, particularly for small sample sizes. Furthermore, we identified break-points in trends over time for both endangered species, indicating shifts in slopes away from strongly increasing trends, but they were only weakly supported by Bayesian change-point analyses (i.e., no step-wise changes in abundance). The break-point and change-point test results, in addition to the early warning signal analyses, support that the two populations do not appear to show signs of critical slowing down or decline.
Waveform inversion of volcano-seismic signals for an extended source
Nakano, M.; Kumagai, H.; Chouet, B.; Dawson, P.
2007-01-01
We propose a method to investigate the dimensions and oscillation characteristics of the source of volcano-seismic signals based on waveform inversion for an extended source. An extended source is realized by a set of point sources distributed on a grid surrounding the centroid of the source in accordance with the source geometry and orientation. The source-time functions for all point sources are estimated simultaneously by waveform inversion carried out in the frequency domain. We apply a smoothing constraint to suppress short-scale noisy fluctuations of source-time functions between adjacent sources. The strength of the smoothing constraint we select is that which minimizes the Akaike Bayesian Information Criterion (ABIC). We perform a series of numerical tests to investigate the capability of our method to recover the dimensions of the source and reconstruct its oscillation characteristics. First, we use synthesized waveforms radiated by a kinematic source model that mimics the radiation from an oscillating crack. Our results demonstrate almost complete recovery of the input source dimensions and source-time function of each point source, but also point to a weaker resolution of the higher modes of crack oscillation. Second, we use synthetic waveforms generated by the acoustic resonance of a fluid-filled crack, and consider two sets of waveforms dominated by the modes with wavelengths 2L/3 and 2W/3, or L and 2L/5, where W and L are the crack width and length, respectively. Results from these tests indicate that the oscillating signature of the 2L/3 and 2W/3 modes are successfully reconstructed. The oscillating signature of the L mode is also well recovered, in contrast to results obtained for a point source for which the moment tensor description is inadequate. However, the oscillating signature of the 2L/5 mode is poorly recovered owing to weaker resolution of short-scale crack wall motions. The triggering excitations of the oscillating cracks are successfully reconstructed. Copyright 2007 by the American Geophysical Union.
Predicting point-of-departure values from the ToxCast data (TDS)
There are less than two-thousand health assessments available for the tens of thousands of chemicals in commerce today. Traditional toxicity testing takes time, money, and resources leading in part to this large discrepancy. Faster and more efficient ways of understanding adverse...
Using Dispersed Modes During Model Correlation
NASA Technical Reports Server (NTRS)
Stewart, Eric; Hathcock, Megan
2017-01-01
Using model dispersions as a starting point allows us to quickly adjust a model to reflect new test data: a) The analyst does a lot of work before the test to save time post-test. b) Creating 1000s of model dispersions to provide "coarse tuning," then use Attune to provide the "fine tuning." ?Successful model tuning on three structures: a) TAURUS. b) Ares I-X C) Cart (in backup charts). ?Mode weighting factors, matrix norm method, and XOR vs. MAC all play key roles in determining the BME. The BME process will be used on future tests: a) ISPE modal test (ongoing work). b) SLS modal test (mid 2018).
Screening and identification of novel B cell epitopes of Toxoplasma gondii SAG1.
Wang, Yanhua; Wang, Guangxiang; Zhang, Delin; Yin, Hong; Wang, Meng
2013-04-30
The identification of protein epitopes is useful for diagnostic purposes and for the development of peptide vaccines. In this study, the epitopes of Toxoplasma gondii SAG1 were identified using synthetic peptide techniques with the aid of bioinformatics. Eleven peptides derived from T. gondii SAG1 were assessed by ELISA using pig sera from different time points after infection. Four (PS4, PS6, PS10 and PS11), out of the eleven peptides tested were recognized by all sera. Then, shorter peptides that were derived from PS4, PS6, PS10 and PS11 were predicted using bioinformatics and tested by experimentation. Four out of nine shorter peptides were identified successfully (amino acids 106-120, 166-180, 289-300 and 313-332). We have precisely located the epitopes of T. gondii SAG1 using pig sera collected at different time points after infection. The identified epitopes may be useful for the further study of epitope-based vaccines and diagnostic reagents.
Lin, Shih-Hsien; Chen, Wei Tseng; Chen, Kao Chin; Lee, Sheng-Yu; Lee, I Hui; Chen, Po See; Yeh, Tzung Lieh; Lu, Ru-Band; Yang, Yen Kuang
2013-01-01
The efficacy of methadone maintenance therapy for heroin dependence is compromised by the low retention rate. Hypothalamus-pituitary-adrenal (HPA) axis function, which is associated with stress response, and novelty seeking (NS), a personality trait associated with low dopaminergic activity, may play roles in retention. We conducted a prospective study in which HPA axis function and NS were assessed by the dexamethasone suppression test and the Tridimensional Personality Questionnaire at baseline, respectively. The retention rate was assessed at the half- and 1-year points of methadone maintenance therapy. A low suppression rate of dexamethasone suppression test (D%) was associated with a high level of NS. A low D% was associated with half-year dropout, whereas a high level of NS was associated with 1-year dropout. Survival analysis confirmed that D% and NS were significant time-dependent covariates for retention. The findings showed that HPA axis function and NA were associated with retention at different time points.
Dupont, S; De Spiegeleer, A; Liu, D J X; Lefère, L; van Doorn, D A; Hesta, M
2016-01-01
Commercial immunoglobulin E (IgE)-based tests are available for diagnosis of food allergies and are commonly used in equine practice. However, these tests have been proven unreliable as a screening method in man and other species, but not critically evaluated in equids. Therefore, a commercially available IgE-based test for horses was evaluated. To evaluate the consistency of the results obtained with a commercially available IgE-based test for food allergy diagnosis in ponies (Phase I) and to subject ponies to a provocation trial with the presumed allergens (Phase II). Allergen screening followed by experimental food provocation trials in healthy ponies. Blood samples of 17 healthy Shetland ponies were taken at 2 different time points, sent blinded to a commercial laboratory for screening of common food allergens and the results were evaluated for consistency (Phase I). Ponies that were positive for food allergens were consecutively challenged orally with each allergen separately for 14 days (Phase II). A washout period of one week was applied in ponies with multiple positive results. Clinical parameters and serum amyloid A were monitored during the provocation trial. Only 7/17 ponies were negative on the IgE-based test at the 2 time points, 3 had positive results twice but only one tested positive twice for the same food allergen. No abnormalities were noted during the provocation trials. This study demonstrated that this IgE-based test is not a reliable screening tool for food allergy in healthy equids. © 2015 EVJ Ltd.
Evaluation of new indigenous "point-of-care" ABO and Rh grouping device.
Tiwari, Aseem Kumar; Setya, Divya; Aggarwal, Geet; Arora, Dinesh; Dara, Ravi C; Ratan, Ankita; Bhardwaj, Gunjan; Acharya, Devi Prasad
2018-01-01
Erycard 2.0 is a "point-of-care" device that is primarily being used for patient blood grouping before transfusion. Erycard 2.0 was compared with conventional slide technology for accuracy and time taken for ABO and Rh forward grouping result with column agglutination technology (CAT) being the gold standard. Erycard 2.0 as a device was also evaluated for its stability under different storage conditions and stability of result till 48 h. In addition, grouping of hemolyzed samples was also tested with Erycard 2.0. Ease of use of Erycard 2.0 was evaluated with a survey among paramedical staff. Erycard 2.0 demonstrated 100% concordance with CAT as compared with slide technique (98.9%). Mean time taken per test by Erycard 2.0 and slide technique was 5.13 min and 1.7 min, respectively. After pretesting storage under different temperature and humidity conditions, Erycard 2.0 did not show any deviation from the result. The result did not change even after 48 h of testing and storage under room temperature. 100% concordance was recorded between pre- and post-hemolyzed blood grouping. Ease of use survey revealed that Erycard 2.0 was more acceptable to paramedical staff for its simplicity, objectivity, and performance than conventional slide technique. Erycard 2.0 can be used as "point-of-care" device for blood donor screening for ABO and Rh blood group and can possibly replace conventional slide technique.
Evaluation of new indigenous “point-of-care” ABO and Rh grouping device
Tiwari, Aseem Kumar; Setya, Divya; Aggarwal, Geet; Arora, Dinesh; Dara, Ravi C.; Ratan, Ankita; Bhardwaj, Gunjan; Acharya, Devi Prasad
2018-01-01
BACKGROUND: Erycard 2.0 is a “point-of-care” device that is primarily being used for patient blood grouping before transfusion. MATERIALS AND METHODS: Erycard 2.0 was compared with conventional slide technology for accuracy and time taken for ABO and Rh forward grouping result with column agglutination technology (CAT) being the gold standard. Erycard 2.0 as a device was also evaluated for its stability under different storage conditions and stability of result till 48 h. In addition, grouping of hemolyzed samples was also tested with Erycard 2.0. Ease of use of Erycard 2.0 was evaluated with a survey among paramedical staff. RESULTS: Erycard 2.0 demonstrated 100% concordance with CAT as compared with slide technique (98.9%). Mean time taken per test by Erycard 2.0 and slide technique was 5.13 min and 1.7 min, respectively. After pretesting storage under different temperature and humidity conditions, Erycard 2.0 did not show any deviation from the result. The result did not change even after 48 h of testing and storage under room temperature. 100% concordance was recorded between pre- and post-hemolyzed blood grouping. Ease of use survey revealed that Erycard 2.0 was more acceptable to paramedical staff for its simplicity, objectivity, and performance than conventional slide technique. CONCLUSION: Erycard 2.0 can be used as “point-of-care” device for blood donor screening for ABO and Rh blood group and can possibly replace conventional slide technique. PMID:29403211
Antenna reconfiguration verification and validation
NASA Technical Reports Server (NTRS)
Becker, Robert C. (Inventor); Meyers, David W. (Inventor); Muldoon, Kelly P. (Inventor); Carlson, Douglas R. (Inventor); Drexler, Jerome P. (Inventor)
2009-01-01
A method of testing the electrical functionality of an optically controlled switch in a reconfigurable antenna is provided. The method includes configuring one or more conductive paths between one or more feed points and one or more test point with switches in the reconfigurable antenna. Applying one or more test signals to the one or more feed points. Monitoring the one or more test points in response to the one or more test signals and determining the functionality of the switch based upon the monitoring of the one or more test points.
Investigation of reliability attributes and accelerated stress factors on terrestrial solar cells
NASA Technical Reports Server (NTRS)
Prince, J. L.; Lathrop, J. W.
1979-01-01
The results of accelerated stress testing of four different types of silicon terrestrial solar cells are discussed. The accelerated stress tests used included bias-temperature tests, bias-temperature-humidity tests, thermal cycle and thermal shock tests, and power cycle tests. Characterization of the cells was performed before stress testing and at periodic down-times, using electrical measurement, visual inspection, and metal adherence pull tests. Electrical parameters measured included short-circuit current, open circuit voltage, and output power, voltage, and current at the maximum power point. Incorporated in the report are the distributions of the prestress electrical data for all cell types. Data were also obtained on cell series and shunt resistance.
Analysis of the postprandial lipid metabolism: use of a 3-point test.
Guerci, B; Paul, J L; Hadjadj, S; Durlach, V; Vergès, B; Attia, N; Girard-Globa, A; Drouin, P
2001-09-01
The oral fat load tests used to study postprandial lipemia are complex and costly and time consuming. A simplified fat load test could be more convenient and more appropriate in routine clinical practice because of the number of lipid determinations required. We evaluated the capacity of a postprandial test model that reduced the number of blood samples taken in thirty three normal weight controls and 17 normotriglyceridemic obese patients (study 1), 10 normolipidemic type 2 diabetic patients and 7 healthy controls (study 2), and 10 hyperlipidemic type 2 diabetic patients studied before and after hypolipidemic therapy (study 3). Blood samples were taken before and up to 8 hours after giving the oral fat load containing retinol. Triglyceride (TG) and retinyl palmitate (RP) concentrations in the plasma, chylomicrons (CM) and non-chylomicron (nCM) fractions were measured. Postprandial lipid responses using conventional area under the curves (AUCc using 5 to 7 lipid determinations) were compared to a 3-point test that uses only three sample points to predict the area under the curve (AUCp: triglycerides at T0, triglycerides at average peak-time (T4), and triglycerides at T8). The AUCc and AUCp for triglycerides and retinyl palmitate were highly correlated in each of the groups and whatever the lipid subfraction (r=0.664 - 0.995, p<0.0001). When incremental AUC (iAUC) were used, the coefficients of correlation for triglycerides remained highly significant between iAUCc and iAUCp (r=0.718 - 0.979, p<0.01 - 0.0001). The same trend of differences was found between cases and controls when AUCp was used instead of AUCc. The means of differences between AUCc and AUCp for triglyceride values were small (0.34 - 0.74 mmol/L.h), and the confidence intervals were acceptable considering the range of the AUCs values (5.60 to 79.8 mmol/L.h for plasma triglycerides). We found that data obtained with a simplified model of AUC using only 3 points to analyse postprandial lipemia are well correlated with those obtained by conventional AUC, and that the AUCp allows to the same conclusions as AUCc when healthy subjects were compared to patients with altered postprandial metabolism. Thus AUCp may be a good evaluation of the AUCc, and the simplified 3-point protocol may well be used and suitable for studies on large groups of subjects who are eligible for an oral fat load test.
Analysis of short single rest/activation epoch fMRI by self-organizing map neural network
NASA Astrophysics Data System (ADS)
Erberich, Stephan G.; Dietrich, Thomas; Kemeny, Stefan; Krings, Timo; Willmes, Klaus; Thron, Armin; Oberschelp, Walter
2000-04-01
Functional magnet resonance imaging (fMRI) has become a standard non invasive brain imaging technique delivering high spatial resolution. Brain activation is determined by magnetic susceptibility of the blood oxygen level (BOLD effect) during an activation task, e.g. motor, auditory and visual tasks. Usually box-car paradigms have 2 - 4 rest/activation epochs with at least an overall of 50 volumes per scan in the time domain. Statistical test based analysis methods need a large amount of repetitively acquired brain volumes to gain statistical power, like Student's t-test. The introduced technique based on a self-organizing neural network (SOM) makes use of the intrinsic features of the condition change between rest and activation epoch and demonstrated to differentiate between the conditions with less time points having only one rest and one activation epoch. The method reduces scan and analysis time and the probability of possible motion artifacts from the relaxation of the patients head. Functional magnet resonance imaging (fMRI) of patients for pre-surgical evaluation and volunteers were acquired with motor (hand clenching and finger tapping), sensory (ice application), auditory (phonological and semantic word recognition task) and visual paradigms (mental rotation). For imaging we used different BOLD contrast sensitive Gradient Echo Planar Imaging (GE-EPI) single-shot pulse sequences (TR 2000 and 4000, 64 X 64 and 128 X 128, 15 - 40 slices) on a Philips Gyroscan NT 1.5 Tesla MR imager. All paradigms were RARARA (R equals rest, A equals activation) with an epoch width of 11 time points each. We used the self-organizing neural network implementation described by T. Kohonen with a 4 X 2 2D neuron map. The presented time course vectors were clustered by similar features in the 2D neuron map. Three neural networks were trained and used for labeling with the time course vectors of one, two and all three on/off epochs. The results were also compared by using a Kolmogorov-Smirnov statistical test of all 66 time points. To remove non- periodical time courses from training an auto-correlation function and bandwidth limiting Fourier filtering in combination with Gauss temporal smoothing was used. None of the trained maps, with one, two and three epochs, were significantly different which indicates that the feature space of only one on/off epoch is sufficient to differentiate between the rest and task condition. We found, that without pre-processing of the data no meaningful results can be achieved because of the huge amount of the non-activated and background voxels represents the majority of the features and is therefore learned by the SOM. Thus it is crucial to remove unnecessary capacity load of the neural network by selection of the training input, using auto-correlation function and/or Fourier spectrum analysis. However by reducing the time points to one rest and one activation epoch either strong auto- correlation or a precise periodical frequency is vanishing. Self-organizing maps can be used to separate rest and activation epochs of with only a 1/3 of the usually acquired time points. Because of the nature of the SOM technique, the pattern or feature separation, only the presence of a state change between the conditions is necessary for differentiation. Also the variance of the individual hemodynamic response function (HRF) and the variance of the spatial different regional cerebral blood flow (rCBF) is learned from the subject and not compared with a fixed model done by statistical evaluation. We found that reducing the information to only a few time points around the BOLD effect was not successful due to delays of rCBF and the insufficient extension of the BOLD feature in the time space. Especially for patient routine observation and pre-surgical planing a reduced scan time is of interest.
Overview of the experimental tests in prototype
NASA Astrophysics Data System (ADS)
Egusquiza, Eduard; Valentín, David; Presas, Alexandre; Valero, Carme
2017-04-01
Experimental tests in prototype are necessary to understand the dynamic behaviour of the machine during different operating points. Hydraulic phenomena as well as its effect on the structure need to be studied in order to avoid instabilities during operation and to extend the life-time of the different components. For this purpose, a complete experimental study of a large Francis turbine prototype has been performed installing several sensors along the machine. Pressure sensors were installed in the penstock, spiral case, runner and draft tube, strain gauges were installed in the runner, vibration sensors were used in the stationary parts and different electrical and operational parameters were also measured. All these signals were acquired simultaneously for different operating points of the turbine.
Evidence-Based Point-of-Care Diagnostics: Current Status and Emerging Technologies
NASA Astrophysics Data System (ADS)
Chan, Cangel Pui Yee; Mak, Wing Cheung; Cheung, Kwan Yee; Sin, King Keung; Yu, Cheuk Man; Rainer, Timothy H.; Renneberg, Reinhard
2013-06-01
Point-of-care (POC) diagnostics brings tests nearer to the site of patient care. The turnaround time is short, and minimal manual interference enables quick clinical management decisions. Growth in POC diagnostics is being continuously fueled by the global burden of cardiovascular and infectious diseases. Early diagnosis and rapid initiation of treatment are crucial in the management of such patients. This review provides the rationale for the use of POC tests in acute coronary syndrome, heart failure, human immunodeficiency virus, and tuberculosis. We also consider emerging technologies that are based on advanced nanomaterials and microfluidics, improved assay sensitivity, miniaturization in device design, reduced costs, and high-throughput multiplex detection, all of which may shape the future development of POC diagnostics.
Advances in Candida detection platforms for clinical and point-of-care applications
Safavieh, Mohammadali; Coarsey, Chad; Esiobu, Nwadiuto; Memic, Adnan; Vyas, Jatin Mahesh; Shafiee, Hadi; Asghar, Waseem
2016-01-01
Invasive candidiasis remains one of the most serious community and healthcare-acquired infections worldwide. Conventional Candida detection methods based on blood and plate culture are time-consuming and require at least 2–4 days to identify various Candida species. Despite considerable advances for candidiasis detection, the development of simple, compact and portable point-of-care diagnostics for rapid and precise testing that automatically performs cell lysis, nucleic acid extraction, purification and detection still remains a challenge. Here, we systematically review most prominent conventional and nonconventional techniques for the detection of various Candida species, including Candida staining, blood culture, serological testing and nucleic acid-based analysis. We also discuss the most advanced lab on a chip devices for candida detection. PMID:27093473
Zercher, Florian; Schmidt, Peter; Cieciuch, Jan; Davidov, Eldad
2015-01-01
Over the last decades, large international datasets such as the European Social Survey (ESS), the European Value Study (EVS) and the World Value Survey (WVS) have been collected to compare value means over multiple time points and across many countries. Yet analyzing comparative survey data requires the fulfillment of specific assumptions, i.e., that these values are comparable over time and across countries. Given the large number of groups that can be compared in repeated cross-national datasets, establishing measurement invariance has been, however, considered unrealistic. Indeed, studies which did assess it often failed to establish higher levels of invariance such as scalar invariance. In this paper we first introduce the newly developed approximate approach based on Bayesian structural equation modeling (BSEM) to assess cross-group invariance over countries and time points and contrast the findings with the results from the traditional exact measurement invariance test. BSEM examines whether measurement parameters are approximately (rather than exactly) invariant. We apply BSEM to a subset of items measuring the universalism value from the Portrait Values Questionnaire (PVQ) in the ESS. The invariance of this value is tested simultaneously across 15 ESS countries over six ESS rounds with 173,071 respondents and 90 groups in total. Whereas, the use of the traditional approach only legitimates the comparison of latent means of 37 groups, the Bayesian procedure allows the latent mean comparison of 73 groups. Thus, our empirical application demonstrates for the first time the BSEM test procedure on a particularly large set of groups. PMID:26089811
Time-elapsed screw insertion with microCT imaging.
Ryan, M K; Mohtar, A A; Cleek, T M; Reynolds, K J
2016-01-25
Time-elapsed analysis of bone is an innovative technique that uses sequential image data to analyze bone mechanics under a given loading regime. This paper presents the development of a novel device capable of performing step-wise screw insertion into excised bone specimens, within the microCT environment, whilst simultaneously recording insertion torque, compression under the screw head and rotation angle. The system is computer controlled and screw insertion is performed in incremental steps of insertion torque. A series of screw insertion tests to failure were performed (n=21) to establish a relationship between the torque at head contact and stripping torque (R(2)=0.89). The test-device was then used to perform step-wise screw insertion, stopping at intervals of 20%, 40%, 60% and 80% between screw head contact and screw stripping. Image data-sets were acquired at each of these time-points as well as at head contact and post-failure. Examination of the image data revealed the trabecular deformation as a result of increased insertion torque was restricted to within 1mm of the outer diameter of the screw thread. Minimal deformation occurred prior to the step between the 80% time-point and post-failure. The device presented has allowed, for the first time, visualization of the micro-mechanical response in the peri-implant bone with increased tightening torque. Further testing on more samples is expected to increase our understanding of the effects of increased tightening torque at the micro-structural level, and the failure mechanisms of trabeculae. Copyright © 2015 Elsevier Ltd. All rights reserved.
Automatic Modelling of Rubble Mound Breakwaters from LIDAR Data
NASA Astrophysics Data System (ADS)
Bueno, M.; Díaz-Vilariño, L.; González-Jorge, H.; Martínez-Sánchez, J.; Arias, P.
2015-08-01
Rubble mound breakwaters maintenance is critical to the protection of beaches and ports. LiDAR systems provide accurate point clouds from the emerged part of the structure that can be modelled to make it more useful and easy to handle. This work introduces a methodology for the automatic modelling of breakwaters with armour units of cube shape. The algorithm is divided in three main steps: normal vector computation, plane segmentation, and cube reconstruction. Plane segmentation uses the normal orientation of the points and the edge length of the cube. Cube reconstruction uses the intersection of three perpendicular planes and the edge length. Three point clouds cropped from the main point cloud of the structure are used for the tests. The number of cubes detected is around 56 % for two of the point clouds and 32 % for the third one over the total physical cubes. Accuracy assessment is done by comparison with manually drawn cubes calculating the differences between the vertexes. It ranges between 6.4 cm and 15 cm. Computing time ranges between 578.5 s and 8018.2 s. The computing time increases with the number of cubes and the requirements of collision detection.
Healy, R.W.; Russell, T.F.
1992-01-01
A finite-volume Eulerian-Lagrangian local adjoint method for solution of the advection-dispersion equation is developed and discussed. The method is mass conservative and can solve advection-dominated ground-water solute-transport problems accurately and efficiently. An integrated finite-difference approach is used in the method. A key component of the method is that the integral representing the mass-storage term is evaluated numerically at the current time level. Integration points, and the mass associated with these points, are then forward tracked up to the next time level. The number of integration points required to reach a specified level of accuracy is problem dependent and increases as the sharpness of the simulated solute front increases. Integration points are generally equally spaced within each grid cell. For problems involving variable coefficients it has been found to be advantageous to include additional integration points at strategic locations in each well. These locations are determined by backtracking. Forward tracking of boundary fluxes by the method alleviates problems that are encountered in the backtracking approaches of most characteristic methods. A test problem is used to illustrate that the new method offers substantial advantages over other numerical methods for a wide range of problems.
Improving energy efficiency in handheld biometric applications
NASA Astrophysics Data System (ADS)
Hoyle, David C.; Gale, John W.; Schultz, Robert C.; Rakvic, Ryan N.; Ives, Robert W.
2012-06-01
With improved smartphone and tablet technology, it is becoming increasingly feasible to implement powerful biometric recognition algorithms on portable devices. Typical iris recognition algorithms, such as Ridge Energy Direction (RED), utilize two-dimensional convolution in their implementation. This paper explores the energy consumption implications of 12 different methods of implementing two-dimensional convolution on a portable device. Typically, convolution is implemented using floating point operations. If a given algorithm implemented integer convolution vice floating point convolution, it could drastically reduce the energy consumed by the processor. The 12 methods compared include 4 major categories: Integer C, Integer Java, Floating Point C, and Floating Point Java. Each major category is further divided into 3 implementations: variable size looped convolution, static size looped convolution, and unrolled looped convolution. All testing was performed using the HTC Thunderbolt with energy measured directly using a Tektronix TDS5104B Digital Phosphor oscilloscope. Results indicate that energy savings as high as 75% are possible by using Integer C versus Floating Point C. Considering the relative proportion of processing time that convolution is responsible for in a typical algorithm, the savings in energy would likely result in significantly greater time between battery charges.
Walsh, J Michael; Flegel, Ron; Cangianelli, Leo A; Atkins, Randolph; Soderstrom, Carl A; Kerns, Timothy J
2004-09-01
The objectives of this research were to (1) determine the incidence and prevalence of alcohol and other drug use among motor vehicle crash (MVC) victims admitted to a regional Level-I trauma center, and (2) to examine the utility of using a rapid point-of-collection (POC) drug-testing device to identify MVC patients with drug involvement. Blood and urine specimens were routinely collected per clinical protocol for each MVC victim at the time of admission. Blood alcohol concentration (BAC) levels were determined per standard clinical protocol. Clinical urine specimens were routinely split so that a POC drug-testing device for the detection of commonly abused drugs (Marijuana, Cocaine, Amphetamines, Methamphetamines, and Opiates) could be compared to that of the standard hospital laboratory analysis of each urine specimen (which also included Barbiturates and Benzodiazepines). In the six-month period of this study, nearly two-thirds of trauma center admissions were victims of motor vehicle crashes. During this time, blood and urine was collected from 322 MVC victims. Toxicology results indicated that 59.3% of MVC victims tested positive for either commonly abused drugs or alcohol. More patients tested positive for drug use than tested positive for alcohol, with 33.5% testing positive for drug use only, 15.8% testing positive for alcohol use only, and 9.9% testing positive for both drugs and alcohol. Less than half (45.2%) of the substance-abusing patients in this study would have been identified by an alcohol test alone. After alcohol, marijuana and benzodiazepines were the most frequently detected drugs. Point of collection (POC) test results correlated well with laboratory results and provide important information to initiate rapid intervention/treatment for substance use problems among injured patients.
Blaya, Joaquín A; Shin, Sonya; Contreras, Carmen; Yale, Gloria; Suarez, Carmen; Asencios, Luis; Kim, Jihoon; Rodriguez, Pablo; Cegielski, Peter; Fraser, Hamish S F
2011-01-01
To evaluate the time to communicate laboratory results to health centers (HCs) between the e-Chasqui web-based information system and the pre-existing paper-based system. Cluster randomized controlled trial in 78 HCs in Peru. In the intervention group, 12 HCs had web access to results via e-Chasqui (point-of-care HCs) and forwarded results to 17 peripheral HCs. In the control group, 22 point-of-care HCs received paper results directly and forwarded them to 27 peripheral HCs. Baseline data were collected for 15 months. Post-randomization data were collected for at least 2 years. Comparisons were made between intervention and control groups, stratified by point-of-care versus peripheral HCs. For point-of-care HCs, the intervention group took less time to receive drug susceptibility tests (DSTs) (median 9 vs 16 days, p<0.001) and culture results (4 vs 8 days, p<0.001) and had a lower proportion of 'late' DSTs taking >60 days to arrive (p<0.001) than the control. For peripheral HCs, the intervention group had similar communication times for DST (median 22 vs 19 days, p=0.30) and culture (10 vs 9 days, p=0.10) results, as well as proportion of 'late' DSTs (p=0.57) compared with the control. Only point-of-care HCs with direct access to the e-Chasqui information system had reduced communication times and fewer results with delays of >2 months. Peripheral HCs had no benefits from the system. This suggests that health establishments should have point-of-care access to reap the benefits of electronic laboratory reporting.
Shin, Sonya; Contreras, Carmen; Yale, Gloria; Suarez, Carmen; Asencios, Luis; Kim, Jihoon; Rodriguez, Pablo; Cegielski, Peter; Fraser, Hamish S F
2010-01-01
Objective To evaluate the time to communicate laboratory results to health centers (HCs) between the e-Chasqui web-based information system and the pre-existing paper-based system. Methods Cluster randomized controlled trial in 78 HCs in Peru. In the intervention group, 12 HCs had web access to results via e-Chasqui (point-of-care HCs) and forwarded results to 17 peripheral HCs. In the control group, 22 point-of-care HCs received paper results directly and forwarded them to 27 peripheral HCs. Baseline data were collected for 15 months. Post-randomization data were collected for at least 2 years. Comparisons were made between intervention and control groups, stratified by point-of-care versus peripheral HCs. Results For point-of-care HCs, the intervention group took less time to receive drug susceptibility tests (DSTs) (median 9 vs 16 days, p<0.001) and culture results (4 vs 8 days, p<0.001) and had a lower proportion of ‘late’ DSTs taking >60 days to arrive (p<0.001) than the control. For peripheral HCs, the intervention group had similar communication times for DST (median 22 vs 19 days, p=0.30) and culture (10 vs 9 days, p=0.10) results, as well as proportion of ‘late’ DSTs (p=0.57) compared with the control. Conclusions Only point-of-care HCs with direct access to the e-Chasqui information system had reduced communication times and fewer results with delays of >2 months. Peripheral HCs had no benefits from the system. This suggests that health establishments should have point-of-care access to reap the benefits of electronic laboratory reporting. PMID:21113076
Shoemaker, Ritchie C; House, Dennis E
2005-01-01
The human health risk for chronic illnesses involving multiple body systems following inhalation exposure to the indoor environments of water-damaged buildings (WDBs) has remained poorly characterized and the subject of intense controversy. The current study assessed the hypothesis that exposure to the indoor environments of WDBs with visible microbial colonization was associated with illness. The study used a cross-sectional design with assessments at five time points, and the interventions of cholestyramine (CSM) therapy, exposure avoidance following therapy, and reexposure to the buildings after illness resolution. The methodological approach included oral administration of questionnaires, medical examinations, laboratory analyses, pulmonary function testing, and measurements of visual function. Of the 21 study volunteers, 19 completed assessment at each of the five time points. Data at Time Point 1 indicated multiple symptoms involving at least four organ systems in all study participants, a restrictive respiratory condition in four participants, and abnormally low visual contrast sensitivity (VCS) in 18 participants. Serum leptin levels were abnormally high and alpha melanocyte stimulating hormone (MSH) levels were abnormally low. Assessments at Time Point 2, following 2 weeks of CSM therapy, indicated a highly significant improvement in health status. Improvement was maintained at Time Point 3, which followed exposure avoidance without therapy. Reexposure to the WDBs resulted in illness reacquisition in all participants within 1 to 7 days. Following another round of CSM therapy, assessments at Time Point 5 indicated a highly significant improvement in health status. The group-mean number of symptoms decreased from 14.9+/-0.8 S.E.M. at Time Point 1 to 1.2+/-0.3 S.E.M., and the VCS deficit of approximately 50% at Time Point 1 was fully resolved. Leptin and MSH levels showed statistically significant improvement. The results indicated that CSM was an effective therapeutic agent, that VCS was a sensitive and specific indicator of neurologic function, and that illness involved systemic and hypothalamic processes. Although the results supported the general hypothesis that illness was associated with exposure to the WDBs, this conclusion was tempered by several study limitations. Exposure to specific agents was not demonstrated, study participants were not randomly selected, and double-blinding procedures were not used. Additional human and animal studies are needed to confirm this conclusion, investigate the role of complex mixtures of bacteria, fungi, mycotoxins, endotoxins, and antigens in illness causation, and characterize modes of action. Such data will improve the assessment of human health risk from chronic exposure to WDBs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, V; Ruan, D; Nguyen, D
Purpose: To test the potential of early Glioblastoma Multiforme (GBM) recurrence detection utilizing image texture pattern analysis in serial MR images post primary treatment intervention. Methods: MR image-sets of six time points prior to the confirmed recurrence diagnosis of a GBM patient were included in this study, with each time point containing T1 pre-contrast, T1 post-contrast, T2-Flair, and T2-TSE images. Eight Gray-level co-occurrence matrix (GLCM) texture features including Contrast, Correlation, Dissimilarity, Energy, Entropy, Homogeneity, Sum-Average, and Variance were calculated from all images, resulting in a total of 32 features at each time point. A confirmed recurrent volume was contoured, alongmore » with an adjacent non-recurrent region-of-interest (ROI) and both volumes were propagated to all prior time points via deformable image registration. A support vector machine (SVM) with radial-basis-function kernels was trained on the latest time point prior to the confirmed recurrence to construct a model for recurrence classification. The SVM model was then applied to all prior time points and the volumes classified as recurrence were obtained. Results: An increase in classified volume was observed over time as expected. The size of classified recurrence maintained at a stable level of approximately 0.1 cm{sup 3} up to 272 days prior to confirmation. Noticeable volume increase to 0.44 cm{sup 3} was demonstrated at 96 days prior, followed by significant increase to 1.57 cm{sup 3} at 42 days prior. Visualization of the classified volume shows the merging of recurrence-susceptible region as the volume change became noticeable. Conclusion: Image texture pattern analysis in serial MR images appears to be sensitive to detecting the recurrent GBM a long time before the recurrence is confirmed by a radiologist. The early detection may improve the efficacy of targeted intervention including radiosurgery. More patient cases will be included to create a generalizable classification model applicable to a larger patient cohort. NIH R43CA183390 and R01CA188300.NSF Graduate Research Fellowship DGE-1144087.« less
Space Suit Portable Life Support System (PLSS) 2.0 Human-in-the-Loop (HITL) Testing
NASA Technical Reports Server (NTRS)
Watts, Carly; Vogel, Matthew
2016-01-01
The space suit Portable Life Support System (PLSS) 2.0 represents the second integrated prototype developed and tested to mature a design that uses advanced technologies to reduce consumables, improve robustness, and provide additional capabilities over the current state of the art. PLSS 2.0 was developed in 2012, with extensive functional evaluations and system performance testing through mid-2014. In late 2014, PLSS 2.0 was integrated with the Mark III space suit in an ambient laboratory environment to facilitate manned testing, designated PLSS 2.0 Human-in-the-Loop (HITL) testing, in which the PLSS prototype performed the primary life support functions, including suit pressure regulation, ventilation, carbon dioxide control, and cooling of the test subject and PLSS avionics. The intent of this testing was to obtain subjective test subject feedback regarding qualitative aspects of PLSS 2.0 performance such as thermal comfort, sounds, smells, and suit pressure fluctuations due to the cycling carbon dioxide removal system, as well as to collect PLSS performance data over a range of human metabolic rates from 500-3000 Btu/hr. Between October 27 and December 18, 2014, nineteen two-hour simulated EVA test points were conducted in which suited test subjects walked on a treadmill to achieve a target metabolic rate. Six test subjects simulated nominal and emergency EVA conditions with varied test parameters including metabolic rate profile, carbon dioxide removal control mode, cooling water temperature, and Liquid Cooling and Ventilation Garment (state of the art or prototype). The nineteen test points achieved more than 60 hours of test time, with 36 hours accounting for simulated EVA time. The PLSS 2.0 test article performed nominally throughout the test series, confirming design intentions for the advanced PLSS. Test subjects' subjective feedback provided valuable insight into thermal comfort and perceptions of suit pressure fluctuations that will influence future advanced PLSS design and testing strategies.
Point-of-care diagnostics: an advancing sector with nontechnical issues.
Huckle, David
2008-11-01
The particular reasons for the relative lack in development of point-of-care (PoC) diagnostics in a business context were discussed in our sister journal, Expert Review of Medical Devices, over 2 years ago. At that time, it could be seen that the concept of PoC testing was being revisited for at least the fifth time in the last 20 years. There had been important advances in technology but, with changes in global healthcare structures and funding, the overall in vitro diagnostics sector has had sluggish growth. Only molecular diagnostics and PoC testing are growing strongly. PoC testing is now a quarter of the total global in vitro diagnostics market, but largely due to use in diabetes monitoring. An increased focus on areas other than glucose self-testing has created a disturbance in the market. An implementation issue from this disturbance is that of control between central laboratories and the proposed sites for PoC testing. Evidence is presented to show that the first step is likely to be increased use in clinics and outpatient facilities closely linked with the laboratory. The aim will be to control the quality of the test, maintenance of equipment and provide support for the clinician in interpretation. The major problem for effective PoC implementation will be the significant changes to patient pathways that are required. The changes will benefit the patient and clinical outcomes but will require healthcare professionals to change their work patterns. This will be an uphill task!
Factors That Affect Academic Performance Among Pharmacy Students
Sansgiry, Sujit S.; Bhosle, Monali; Sail, Kavita
2006-01-01
Objective The objective of this study was to examine factors such as academic competence, test competence, time management, strategic studying, and test anxiety, and identify whether these factors could distinguish differences among students, based on academic performance and enrollment in the experiential program. Methods A cross-sectional study design utilizing questionnaires measuring previously validated constructs was used to evaluate the effect of these factors on students with low and high cumulative grade point averages (GPAs). Pharmacy students (N = 198) enrolled at the University of Houston participated in the study. Results Academic performance was significantly associated with factors such as academic competence and test competence. Students with a cumulative GPA of 3.0 or greater significantly differed in their level of test competence than those with a GPA of less than 3.0. Students enrolled in their experiential year differed from students enrolled in their second year of curriculum on factors such as test anxiety, academic competence, test competence, and time management skills. Conclusion Test competence was an important factor to distinguish students with low vs. high academic performance. Factors such as academic competence, test competence, test anxiety and time management improve as students' progress in their experiential year. PMID:17149433
Factors that affect academic performance among pharmacy students.
Sansgiry, Sujit S; Bhosle, Monali; Sail, Kavita
2006-10-15
The objective of this study was to examine factors such as academic competence, test competence, time management, strategic studying, and test anxiety, and identify whether these factors could distinguish differences among students, based on academic performance and enrollment in the experiential program. A cross-sectional study design utilizing questionnaires measuring previously validated constructs was used to evaluate the effect of these factors on students with low and high cumulative grade point averages (GPAs). Pharmacy students (N = 198) enrolled at the University of Houston participated in the study. Academic performance was significantly associated with factors such as academic competence and test competence. Students with a cumulative GPA of 3.0 or greater significantly differed in their level of test competence than those with a GPA of less than 3.0. Students enrolled in their experiential year differed from students enrolled in their second year of curriculum on factors such as test anxiety, academic competence, test competence, and time management skills. Test competence was an important factor to distinguish students with low vs. high academic performance. Factors such as academic competence, test competence, test anxiety and time management improve as students' progress in their experiential year.
Insulation bonding test system
NASA Technical Reports Server (NTRS)
Beggs, J. M.; Johnston, G. D.; Coleman, A. D.; Portwood, J. N.; Saunders, J. M.; Redmon, J. W.; Porter, A. C. (Inventor)
1984-01-01
A method and a system for testing the bonding of foam insulation attached to metal is described. The system involves the use of an impacter which has a calibrated load cell mounted on a plunger and a hammer head mounted on the end of the plunger. When the impacter strikes the insulation at a point to be tested, the load cell measures the force of the impact and the precise time interval during which the hammer head is in contact with the insulation. This information is transmitted as an electrical signal to a load cell amplifier where the signal is conditioned and then transmitted to a fast Fourier transform (FFT) analyzer. The FFT analyzer produces energy spectral density curves which are displayed on a video screen. The termination frequency of the energy spectral density curve may be compared with a predetermined empirical scale to determine whether a igh quality bond, good bond, or debond is present at the point of impact.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krityakierne, Tipaluck; Akhtar, Taimoor; Shoemaker, Christine A.
This paper presents a parallel surrogate-based global optimization method for computationally expensive objective functions that is more effective for larger numbers of processors. To reach this goal, we integrated concepts from multi-objective optimization and tabu search into, single objective, surrogate optimization. Our proposed derivative-free algorithm, called SOP, uses non-dominated sorting of points for which the expensive function has been previously evaluated. The two objectives are the expensive function value of the point and the minimum distance of the point to previously evaluated points. Based on the results of non-dominated sorting, P points from the sorted fronts are selected as centersmore » from which many candidate points are generated by random perturbations. Based on surrogate approximation, the best candidate point is subsequently selected for expensive evaluation for each of the P centers, with simultaneous computation on P processors. Centers that previously did not generate good solutions are tabu with a given tenure. We show almost sure convergence of this algorithm under some conditions. The performance of SOP is compared with two RBF based methods. The test results show that SOP is an efficient method that can reduce time required to find a good near optimal solution. In a number of cases the efficiency of SOP is so good that SOP with 8 processors found an accurate answer in less wall-clock time than the other algorithms did with 32 processors.« less
Flowfield Analysis of a Small Entry Probe (SPRITE) Tested in an Arc Jet
NASA Technical Reports Server (NTRS)
Prabhu, Dinesh K.
2011-01-01
Results of simulations of flow of an arc-heated stream around a 14-inch diameter 45 sphere-cone configuration are presented. Computations are first benchmarked against pressure and heat flux measurements made using copper slug calorimeters of different shapes and sizes. The influence of catalycity of copper on computed results is investigated. Good agreements between predictions and measurements are obtained by assuming the copper slug to be partially catalytic to atomic recombination. With total enthalpy estimates obtained from these preliminary computations, calculations are then performed for the test article, with the nozzle and test article considered as an integrated whole the same procedure adopted for calorimeter simulations. The resulting heat fluxes at select points on the test article (points at which fully instrumented plugs were placed) are used in material thermal response code calculations. Predicted time histories of temperature are compared against thermocouple data from the instrumented plugs, and recession determined. Good agreement is obtained for in-depth thermocouples.
Variation in aluminium patch test reactivity over time.
Siemund, Ingrid; Mowitz, Martin; Zimerson, Erik; Bruze, Magnus; Hindsén, Monica
2017-11-01
Contact allergy to aluminium has been reported more frequently in recent years. It has been pointed out that positive patch test reactions to aluminium may not be reproducible on retesting. To investigate possible variations in patch test reactivity to aluminium over time. Twenty-one adults, who had previously reacted positively to aluminium, were patch tested with equimolar dilution series in pet. of aluminium chloride hexahydrate and aluminium lactate, four times over a period of 8 months. Thirty-six of 84 (43%) serial dilution tests with aluminium chloride hexahydrate and 49 of 84 (58%) serial dilution tests with aluminium lactate gave negative results. The range of reactivity varied between a negative reaction to aluminium chloride hexahydrate at 10% and/or to aluminium lactate at 12%, and a positive reaction to aluminium chloride hexahydrate at 0.1% and/or to aluminium lactate at 0.12%. The highest individual difference in test reactivity noticed was 320-fold when the two most divergent minimal eliciting concentrations were compared. The patch test reactivity to aluminium varies over time. Aluminium-allergic individuals may have false-negative reactions. Therefore, retesting with aluminium should be considered when there is a strong suspicion of aluminium contact allergy. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.