Common tester platform concept.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurst, Michael James
This report summarizes the results of a case study on the doctrine of a common tester platform, a concept of a standardized platform that can be applicable across the broad spectrum of testing requirements throughout the various stages of a weapons program, as well as across the various weapons programs. The common tester concept strives to define an affordable, next-generation design that will meet testing requirements with the flexibility to grow and expand; supporting the initial development stages of a weapons program through to the final production and surveillance stages. This report discusses a concept investing key leveraging technologies andmore » operational concepts combined with prototype tester-development experiences and practical lessons learned gleaned from past weapons programs.« less
Test strategies for industrial testers for converter controls equipment
NASA Astrophysics Data System (ADS)
Oleniuk, P.; Di Cosmo, M.; Kasampalis, V.; Nisbet, D.; Todd, B.; Uznański, S.
2017-04-01
Power converters and their controls electronics are key elements for the operation of the CERN accelerator complex, having a direct impact on its availability. To prevent early-life failures and provide means to verify electronics, a set of industrial testers is used throughout the converters controls electronics' life cycle. The roles of the testers are to validate mass production during the manufacturing phase and to provide means to diagnose and repair failed modules that are brought back from operation. In the converter controls electronics section of the power converters group in the technology department of CERN (TE/EPC/CCE), two main test platforms have been adopted: a PXI platform for mixed analogue-digital functional tests and a JTAG Boundary-Scan platform for digital interconnection and functional tests. Depending on the functionality of the device under test, the appropriate test platforms are chosen. This paper is a follow-up to results presented at the TWEPP 2015 conference, adding the boundary scan test platform and the first results from exploitation of the test system. This paper reports on the test software, hardware design and test strategy applied for a number of devices that has resulted in maximizing test coverage and minimizing test design effort.
Kettlgruber, Gerald; Siket, Christian M.; Drack, Michael; Graz, Ingrid M.; Cakmak, Umut; Major, Zoltan; Kaltenbrunner, Martin; Bauer, Siegfried
2016-01-01
Toy bricks are an ideal platform for the cost‐effective rapid prototyping of a tabletop tensile tester with measurement accuracy on par with expensive, commercially available laboratory equipment. Here, a tester is presented that is not only a versatile demonstration device in mechanics, electronics, and physics education and an eye‐catcher on exhibitions, but also a powerful tool for stretchable electronics research. Following the “open‐source movement” the build‐up of the tester is described and all the details for easy reproduction are disclosed. A a new design of highly conformable all‐elastomer based graded rigid island printed circuit boards is developed. Tough bonded to this elastomer substrate are imperceptible electronic foils bearing conductors and off‐the‐shelf microelectronics, paving the way for next generation smart electronic appliances. PMID:27588259
Portable life support for instrumentation of an offshore platform
NASA Technical Reports Server (NTRS)
Mull, M. M.; Coffin, C. L.
1972-01-01
A compressor was used to supply air through a nylon hose to the offshore platform field engineer working at the bottom of the piling. Air quality in the pile was sampled periodically for carbon dioxide, carbon monoxide, hydrogen sulfide, and combustible gases by an universal tester and an explosion meter.
NASA Technical Reports Server (NTRS)
Holmes, Alan M.; Champagne, James W.
1989-01-01
Record of energy relationships retrieved from compact, portable tester. Spring-blade impact tester developed to support evaluation of tolerance to damage of struts under consideration for use in Space Station. Approach offers potential for determining damage as function of change in relationship between applied and absorbed energies as applied energy successively increased with each impact. Impactor strikes specimen at moment of maximum kinetic energy after spring blades released from cocked position. Concept also provides potential for measuring behavior during impact, and energy relationships retrievable from oscilloscope traces of impact.
Electrical Power Subsystem Integration and Test for the NPS Solar Cell Array Tester CubeSat
2010-12-01
Earth’s Gravitational Constant MCU Microcontroller Unit MPPT Maximum Power Point Tracker NiCr Nickel Chromium NPS Naval Postgraduate School P...new testing platform was designed, built, and used to conduct integrated testing on CubeSat Kit (CSK) compatible devices. The power budgets and...acceptance test results obtained from the testing platform were used with a solar array power generation simulation, and a battery state of charge
A dynamic tester to evaluate the thermal and moisture behaviour of the surface of textiles.
Li, Wenbin; Xu, Weilin; Wang, Hao; Wang, Xin
2016-01-01
The thermal and moisture behaviour of the microclimate of textiles is crucial in determining the physiological comfort of apparel, but it has not been investigated sufficiently due to the lack of particular evaluation techniques. Based on sensing, temperature controlling and wireless communicating technology, a specially designed tester has been developed in this study to evaluate the thermal and moisture behaviour of the surface of textiles in moving status. A temperature acquisition system and a temperature controllable hotplate have been established to test temperature and simulate the heat of human body, respectively. Relative humidity of the surface of fabric in the dynamic process has been successfully tested through sensing. Meanwhile, wireless communication technology was applied to transport the acquired data of temperature and humidity to computer for further processing. Continuous power supply was achieved by intensive contact between an elastic copper plate and copper ring on the rotating shaft. This tester provides the platform to evaluate the thermal and moisture behaviour of textiles. It enables users to conduct a dynamic analysis on the temperature and humidity together with the thermal and moisture transport behaviour of the surface of fabric in moving condition. Development of this tester opens the door of investigation on the micro-climate of textiles in real time service, and eventually benefits the understanding of the sensation comfort and wellbeing of apparel wearers. Copyright © 2015 Elsevier Ltd. All rights reserved.
Automating testbed documentation and database access using World Wide Web (WWW) tools
NASA Technical Reports Server (NTRS)
Ames, Charles; Auernheimer, Brent; Lee, Young H.
1994-01-01
A method for providing uniform transparent access to disparate distributed information systems was demonstrated. A prototype testing interface was developed to access documentation and information using publicly available hypermedia tools. The prototype gives testers a uniform, platform-independent user interface to on-line documentation, user manuals, and mission-specific test and operations data. Mosaic was the common user interface, and HTML (Hypertext Markup Language) provided hypertext capability.
NASA Astrophysics Data System (ADS)
Turner, Michael Lloyd
Research on student difficulties in learning physics concepts has been coincident with a general reform movement in science education with the aim of increasing the level of inquiry in the teaching and learning of science. Coincident with these efforts has been a dramatic increase in the offering of online courses. Generally, this movement toward online course offerings has taken place without the inclusion of laboratory science offerings. The Learn Anytime Anywhere Physics (LAAPhysics) program for asynchronous online introductory physics learning is a notable exception. LAAPhysics software attempts to implement the principles of reformed science teaching and learning in an online environment. The purpose of this study was to measure how student cognition of physics concepts in kinematics was effected through use of LAAPhysics online kinematics tutorials. The normalized gains between pre-instruction and post-instruction scores on the Test of Understanding Graphs in Kinematics (TUG-K) for a treatment group of LAAPhysics testers was calculated. This normalized gain was compared to normalized gains typically found for students taking face-to-face physics courses. The normalized gain scores for LAAPhysics testers were also tested for correlation against time on task variables as measured by connectivity to the online software. Finally, a content analysis of student responses recorded in the LAAPhysics software was conducted. Normalized gain scores for LAAPhysics testers were not found to be greater than gain scores typically found in face-to-face courses. The number of student connections to the software and their total time working in the software were found to be significantly related to normalized gain on the TUG-K. The content analysis of student responses in the LAAPhysics software revealed variation in initial understanding of physics concepts in kinematics as well as variation in change in understanding across students.
Finger wear detection for production line battery tester
Depiante, Eduardo V.
1997-01-01
A method for detecting wear in a battery tester probe. The method includes providing a battery tester unit having at least one tester finger, generating a tester signal using the tester fingers and battery tester unit with the signal characteristic of the electrochemical condition of the battery and the tester finger, applying wavelet transformation to the tester signal including computing a mother wavelet to produce finger wear indicator signals, analyzing the signals to create a finger wear index, comparing the wear index for the tester finger with the index for a new tester finger and generating a tester finger signal change signal to indicate achieving a threshold wear change.
Finger wear detection for production line battery tester
Depiante, E.V.
1997-11-18
A method is described for detecting wear in a battery tester probe. The method includes providing a battery tester unit having at least one tester finger, generating a tester signal using the tester fingers and battery tester unit with the signal characteristic of the electrochemical condition of the battery and the tester finger, applying wavelet transformation to the tester signal including computing a mother wavelet to produce finger wear indicator signals, analyzing the signals to create a finger wear index, comparing the wear index for the tester finger with the index for a new tester finger and generating a tester finger signal change signal to indicate achieving a threshold wear change. 9 figs.
Design review of fluid film bearing testers
NASA Technical Reports Server (NTRS)
Scharrer, Joseph K.
1993-01-01
The designs of three existing testers (Hybrid Bearing Tester, OTV Bearing Tester, and Long Life Bearing Tester) owned by NASA were reviewed for their capability to serve as a multi-purpose cryogenic fluid film bearing tester. The primary tester function is the validation of analytical predictions for fluid film bearing steady state and dynamic performance. Evaluation criteria were established for test bearing configurations, test fluids, instrumentation, and test objectives. Each tester was evaluated with respect to these criteria. A determination was made of design improvements which would allow the testers to meet the stated criteria. The cost and time required to make the design changes were estimated. A recommendation based on the results of this study was made to proceed with the Hybrid Bearing Tester.
Evolutionary space platform concept study. Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
1982-01-01
The Evolutionary Space Platform Concept Study encompassed a 10 month effort to define, evaluate and compare approaches and concepts for evolving unmanned and manned capability platforms beyond the current Space Platform concepts to an evolutionary goal of establishing a permanent manned presence in space. Areas addressed included: special emphasis trade studies on the current unmanned concept, assessment of manned platform concepts, and utility analysis of a manned platform for defense related missions.
Michael's Inform Test of Student Ability (M.I.T.O.S.A.). Tester's Manual.
ERIC Educational Resources Information Center
Grafius, Thomas M.
Michael's Informal Test of Student Ability (MITOSA) is a diagnostic evaluative tool for adult students designed to test nine skills abilities in adult students functioning below a tenth grade level. The nine test sections are approximate reading level, understanding of basic math concepts and symbols, general thinking/reasoning ability, eye-hand…
Evolutionary space platform concept study. Volume 2, part B: Manned space platform concepts
NASA Technical Reports Server (NTRS)
1982-01-01
Logical, cost-effective steps in the evolution of manned space platforms are investigated and assessed. Tasks included the analysis of requirements for a manned space platform, identifying alternative concepts, performing system analysis and definition of the concepts, comparing the concepts and performing programmatic analysis for a reference concept.
O'Connor, S; McCaffrey, N; Whyte, E; Moran, K
2016-07-01
To adapt the trunk stability test to facilitate further sub-classification of higher levels of core stability in athletes for use as a screening tool. To establish the inter-tester and intra-tester reliability of this adapted core stability test. Reliability study. Collegiate athletic therapy facilities. Fifteen physically active male subjects (19.46 ± 0.63) free from any orthopaedic or neurological disorders were recruited from a convenience sample of collegiate students. The intraclass correlation coefficients (ICC) and 95% Confidence Intervals (CI) were computed to establish inter-tester and intra-tester reliability. Excellent ICC values were observed in the adapted core stability test for inter-tester reliability (0.97) and good to excellent intra-tester reliability (0.73-0.90). While the 95% CI were narrow for inter-tester reliability, Tester A and C 95% CI's were widely distributed compared to Tester B. The adapted core stability test developed in this study is a quick and simple field based test to administer that can further subdivide athletes with high levels of core stability. The test demonstrated high inter-tester and intra-tester reliability. Copyright © 2015 Elsevier Ltd. All rights reserved.
Development of a second generation rolling contact fatigue tester
NASA Astrophysics Data System (ADS)
Deshmukh, Satyam U.
Contact fatigue failure has been in research since the early twentieth century. The need for a second generation sliding-rolling contact fatigue tester was proposed by Gregory Dvorak and Dr. Marcellin Zahui. The first generation RCF tester was used for testing super finishing processes for gear surfaces. The second generation RCF tester was funded by the Advanced Engineering Materials lab of University of North Dakota. Verification of the second generation Rolling Contact Fatigue Tester will be discussed in this thesis including the design details, assembly and testing procedure and to discuss its different parameters. The tester will have the capability of testing hollow specimens using a bobbin eddy current testing probe. This tester will allow a wide range of experiments and is not built for one specific purpose. An eddy current device is used for detecting cracks. The loading force is applied using hydraulic cylinders and a hydraulic power unit. Before testing began, the machine was run for some time at full speed. A lot of minor problems were detected and fixed. Three specimens of AISI 8620 were tested in this tester. All tests gave results matching with some of the other well-known RCF testers. These tests were performed to evaluate mechanical limits of the tester and to evaluate the software performance of the tester.
Practical End-to-End Performance Testing Tool for High Speed 3G-Based Networks
NASA Astrophysics Data System (ADS)
Shinbo, Hiroyuki; Tagami, Atsushi; Ano, Shigehiro; Hasegawa, Toru; Suzuki, Kenji
High speed IP communication is a killer application for 3rd generation (3G) mobile systems. Thus 3G network operators should perform extensive tests to check whether expected end-to-end performances are provided to customers under various environments. An important objective of such tests is to check whether network nodes fulfill requirements to durations of processing packets because a long duration of such processing causes performance degradation. This requires testers (persons who do tests) to precisely know how long a packet is hold by various network nodes. Without any tool's help, this task is time-consuming and error prone. Thus we propose a multi-point packet header analysis tool which extracts and records packet headers with synchronized timestamps at multiple observation points. Such recorded packet headers enable testers to calculate such holding durations. The notable feature of this tool is that it is implemented on off-the shelf hardware platforms, i.e., lap-top personal computers. The key challenges of the implementation are precise clock synchronization without any special hardware and a sophisticated header extraction algorithm without any drop.
46 CFR 30.10-27 - Flashpoint-TB/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... gives off a flammable vapor when heated in an open-cup tester. For the purpose of the regulations in... with an open-cup tester, as follows: Table 30.10-27—Equivalent Flashpoints [In degrees Farenheit] Open-cup tester Tag closed-cup tester (A.S.T.M.) Pensky-Martens closed tester (A.S.T.M.) 80 75 150 140 ...
46 CFR 30.10-27 - Flashpoint-TB/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
... gives off a flammable vapor when heated in an open-cup tester. For the purpose of the regulations in... with an open-cup tester, as follows: Table 30.10-27—Equivalent Flashpoints [In degrees Farenheit] Open-cup tester Tag closed-cup tester (A.S.T.M.) Pensky-Martens closed tester (A.S.T.M.) 80 75 150 140 ...
Spring performance tester for miniature extension springs
Salzbrenner, Bradley; Boyce, Brad
2017-05-16
A spring performance tester and method of testing a spring are disclosed that has improved accuracy and precision over prior art spring testers. The tester can perform static and cyclic testing. The spring tester can provide validation for product acceptance as well as test for cyclic degradation of springs, such as the change in the spring rate and fatigue failure.
Albumin testing in urine using a smart-phone
Coskun, Ahmet F.; Nagi, Richie; Sadeghi, Kayvon; Phillips, Stephen; Ozcan, Aydogan
2013-01-01
We demonstrate a digital sensing platform, termed Albumin Tester, running on a smart-phone that images and automatically analyses fluorescent assays confined within disposable test tubes for sensitive and specific detection of albumin in urine. This light-weight and compact Albumin Tester attachment, weighing approximately 148 grams, is mechanically installed on the existing camera unit of a smart-phone, where test and control tubes are inserted from the side and are excited by a battery powered laser diode. This excitation beam, after probing the sample of interest located within the test tube, interacts with the control tube, and the resulting fluorescent emission is collected perpendicular to the direction of the excitation, where the cellphone camera captures the images of the fluorescent tubes through the use of an external plastic lens that is inserted between the sample and the camera lens. The acquired fluorescent images of the sample and control tubes are digitally processed within one second through an Android application running on the same cellphone for quantification of albumin concentration in urine specimen of interest. Using a simple sample preparation approach which takes ~ 5 minutes per test (including the incubation time), we experimentally confirmed the detection limit of our sensing platform as 5–10 μg/mL (which is more than 3 times lower than clinically accepted normal range) in buffer as well as urine samples. This automated albumin testing tool running on a smart-phone could be useful for early diagnosis of kidney disease or for monitoring of chronic patients, especially those suffering from diabetes, hypertension, and/or cardiovascular diseases. PMID:23995895
Single wheel testers, single track testers, and instrumented tractors
USDA-ARS?s Scientific Manuscript database
Single wheel testers and single track testers are used for determining tractive performance characteristics of tires and tracks. Instrumented tractors are useful in determining the tractive performance of tractors. These machines are also used for determining soil-tire and soil-track interactions,...
21 CFR 870.3720 - Pacemaker electrode function tester.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pacemaker electrode function tester. 870.3720... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3720 Pacemaker electrode function tester. (a) Identification. A pacemaker electrode function tester is a device which is...
21 CFR 870.3720 - Pacemaker electrode function tester.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pacemaker electrode function tester. 870.3720... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3720 Pacemaker electrode function tester. (a) Identification. A pacemaker electrode function tester is a device which is...
21 CFR 870.3720 - Pacemaker electrode function tester.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pacemaker electrode function tester. 870.3720... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3720 Pacemaker electrode function tester. (a) Identification. A pacemaker electrode function tester is a device which is...
21 CFR 870.3720 - Pacemaker electrode function tester.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pacemaker electrode function tester. 870.3720... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3720 Pacemaker electrode function tester. (a) Identification. A pacemaker electrode function tester is a device which is...
21 CFR 870.5325 - Defibrillator tester.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Defibrillator tester. 870.5325 Section 870.5325...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5325 Defibrillator tester. (a) Identification. A defibrillator tester is a device that is connected to the output of a...
21 CFR 870.5325 - Defibrillator tester.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Defibrillator tester. 870.5325 Section 870.5325...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5325 Defibrillator tester. (a) Identification. A defibrillator tester is a device that is connected to the output of a...
21 CFR 870.5325 - Defibrillator tester.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Defibrillator tester. 870.5325 Section 870.5325...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5325 Defibrillator tester. (a) Identification. A defibrillator tester is a device that is connected to the output of a...
21 CFR 870.5325 - Defibrillator tester.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Defibrillator tester. 870.5325 Section 870.5325...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5325 Defibrillator tester. (a) Identification. A defibrillator tester is a device that is connected to the output of a...
21 CFR 870.5325 - Defibrillator tester.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Defibrillator tester. 870.5325 Section 870.5325...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5325 Defibrillator tester. (a) Identification. A defibrillator tester is a device that is connected to the output of a...
21 CFR 882.1410 - Electroencephalograph electrode/lead tester.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Electroencephalograph electrode/lead tester. 882... Electroencephalograph electrode/lead tester. (a) Identification. An electroencephalograph electrode/lead tester is a device used for testing the impedance (resistance to alternating current) of the electrode and lead...
21 CFR 882.1410 - Electroencephalograph electrode/lead tester.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Electroencephalograph electrode/lead tester. 882... Electroencephalograph electrode/lead tester. (a) Identification. An electroencephalograph electrode/lead tester is a device used for testing the impedance (resistance to alternating current) of the electrode and lead...
21 CFR 882.1410 - Electroencephalograph electrode/lead tester.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Electroencephalograph electrode/lead tester. 882... Electroencephalograph electrode/lead tester. (a) Identification. An electroencephalograph electrode/lead tester is a device used for testing the impedance (resistance to alternating current) of the electrode and lead...
21 CFR 870.3720 - Pacemaker electrode function tester.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker electrode function tester. 870.3720... electrode function tester. (a) Identification. A pacemaker electrode function tester is a device which is... measuring the patient's pacing threshold and intracardiac R-wave potential. (b) Classification. Class II...
Developing the concept of a geostationary platform. [for communication services
NASA Technical Reports Server (NTRS)
Carey, W. T.; Bowman, R. M.; Stone, G. R.
1980-01-01
A geostationary platform concept with a proliferation of low-cost earth stations is discussed. Candidate platform concepts, servicing, life, and Orbital Transfer Vehicle (OTV) options are considered. A Life Cycle Costing model is used to select the minimum cost concept meeting program criteria. It is concluded that the geostationary platform concept is a practical and economical approach to providing expanding communication services within the limitations imposed by the available frequency spectrum and orbital arc.
ERIC Educational Resources Information Center
Eckert, Douglas
This training manual, which was developed for employees of an automotive plant, is designed to teach trainees to operate a portable weld tester (Miyachi MM-315). In chapter 1, the weld tester's components are illustrated and described, and the procedure for charging its batteries is explained. Chapter 2 illustrates the weld tester's parts,…
21 CFR 886.1170 - Color vision tester.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Color vision tester. 886.1170 Section 886.1170...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1170 Color vision tester. (a) Identification. A color vision tester is a device that consists of various colored materials, such as colored yarns...
21 CFR 886.1170 - Color vision tester.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Color vision tester. 886.1170 Section 886.1170...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1170 Color vision tester. (a) Identification. A color vision tester is a device that consists of various colored materials, such as colored yarns...
21 CFR 886.1170 - Color vision tester.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Color vision tester. 886.1170 Section 886.1170...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1170 Color vision tester. (a) Identification. A color vision tester is a device that consists of various colored materials, such as colored yarns...
A simplified ductile-brittle transition temperature tester
NASA Technical Reports Server (NTRS)
Arias, A.
1973-01-01
The construction and operation of a versatile, simplified bend tester is described. The tester is usable at temperatures from - 192 to 650 C in air. Features of the tester include a single test chamber for cryogenic or elevated temperatures, specimen alining support rollers, and either manual or motorized operation.
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2012 CFR
2012-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2014 CFR
2014-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2011 CFR
2011-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2013 CFR
2013-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
21 CFR 886.1170 - Color vision tester.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Color vision tester. 886.1170 Section 886.1170...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1170 Color vision tester. (a) Identification. A color vision tester is a device that consists of various colored materials, such as colored yarns...
21 CFR 886.1170 - Color vision tester.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Color vision tester. 886.1170 Section 886.1170...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1170 Color vision tester. (a) Identification. A color vision tester is a device that consists of various colored materials, such as colored yarns...
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2010 CFR
2010-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
Functional and nonfunctional testing of ATM networks
NASA Astrophysics Data System (ADS)
Ricardo, Manuel; Ferreira, M. E. P.; Guimaraes, Francisco E.; Mamede, J.; Henriques, M.; da Silva, Jorge A.; Carrapatoso, E.
1995-02-01
ATM network will support new multimedia services that will require new protocols, those services and protocols will need different test strategies and tools. In this paper, the concepts of functional and non-functional testers of ATM networks are discussed, a multimedia service and its requirements are presented and finally, a summary description of an ATM network and of the test tool that will be used to validate it are presented.
NASA Technical Reports Server (NTRS)
Howard, J. W.; Kim, H.; Berg, M.; LaBel, K. A.; Stansberry, S.; Friendlich, M.; Irwin, T.
2006-01-01
A viewgraph presentation on the development of a low cost, high speed tester reconfigurable Field Programmable Gata Array (FPGA) is shown. The topics include: 1) Introduction; 2) Objectives; 3) Tester Descriptions; 4) Tester Validations and Demonstrations; 5) Future Work; and 6) Summary.
21 CFR 874.1090 - Auditory impedance tester.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Auditory impedance tester. 874.1090 Section 874...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Diagnostic Devices § 874.1090 Auditory impedance tester. (a) Identification. An auditory impedance tester is a device that is intended to change the air pressure in the...
21 CFR 874.1090 - Auditory impedance tester.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Auditory impedance tester. 874.1090 Section 874...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Diagnostic Devices § 874.1090 Auditory impedance tester. (a) Identification. An auditory impedance tester is a device that is intended to change the air pressure in the...
The reliability of knee joint position testing using electrogoniometry
Piriyaprasarth, Pagamas; Morris, Meg E; Winter, Adele; Bialocerkowski, Andrea E
2008-01-01
Background The current investigation examined the inter- and intra-tester reliability of knee joint angle measurements using a flexible Penny and Giles Biometric® electrogoniometer. The clinical utility of electrogoniometry was also addressed. Methods The first study examined the inter- and intra-tester reliability of measurements of knee joint angles in supine, sitting and standing in 35 healthy adults. The second study evaluated inter-tester and intra-tester reliability of knee joint angle measurements in standing and after walking 10 metres in 20 healthy adults, using an enhanced measurement protocol with a more detailed electrogoniometer attachment procedure. Both inter-tester reliability studies involved two testers. Results In the first study, inter-tester reliability (ICC[2,10]) ranged from 0.58–0.71 in supine, 0.68–0.79 in sitting and 0.57–0.80 in standing. The standard error of measurement between testers was less than 3.55° and the limits of agreement ranged from -12.51° to 12.21°. Reliability coefficients for intra-tester reliability (ICC[3,10]) ranged from 0.75–0.76 in supine, 0.86–0.87 in sitting and 0.87–0.88 in standing. The standard error of measurement for repeated measures by the same tester was less than 1.7° and the limits of agreement ranged from -8.13° to 7.90°. The second study showed that using a more detailed electrogoniometer attachment protocol reduced the error of measurement between testers to 0.5°. Conclusion Using a standardised protocol, reliable measures of knee joint angles can be gained in standing, supine and sitting by using a flexible goniometer. PMID:18211714
Intertester reliability of the acceptable noise level.
Gordon-Hickey, Susan; Adams, Elizabeth; Moore, Robert; Gaal, Ashley; Berry, Katie; Brock, Sommer
2012-01-01
The acceptable noise level (ANL) serves to accurately predict the listener's likelihood of success with amplification. It has been proposed as a pre-hearing aid fitting protocol for hearing aid selection and counseling purposes. The ANL is a subjective measure of the listener's ability to accept background noise. Measurement of ANL relies on the tester and listener to follow the instructions set forth. To date, no research has explored the reliability of ANL as measured across clinicians or testers. To examine the intertester reliability of ANL. A descriptive quasi-experimental reliability study was completed. ANL was measured for one group of listeners by three testers. Three participants served as testers. Each tester was familiar with basic audiometry. Twenty-five young adults with normal hearing served as listeners. Each tester was stationed in a laboratory with the needed equipment. Listeners were instructed to report to these laboratories in a random order provided by the experimenters. The testers assessed most comfortable listening level (MCL) and background noise level (BNL) for all 25 listeners. Intraclass correlation coefficients were significant and revealed that MCL, BNL, and ANLs are reliable across testers. Additionally, one-way ANOVAs for MCL, BNL, and ANL were not significant. These findings indicate that MCL, BNL, and ANL do not differ significantly when measured by different testers. If the ANL instruction set is accurately followed, ANL can be reliably measured across testers, laboratories, and clinics. Intertester reliability of ANL allows for comparison across ANLs measured by different individuals. Findings of the present study indicate that tester reliability can be ruled out as a factor contributing to the disparity of mean ANLs reported in the literature. American Academy of Audiology.
Geosynchronous platform definition study. Volume 5: Geosynchronous platform synthesis
NASA Technical Reports Server (NTRS)
1973-01-01
The development is described of the platform configurations, support subsystems, mission equipment, and servicing concepts. A common support module is developed; subsystem concepts are traded off; data relay, TDRS, earth observational, astro-physics, and advanced navigation and traffic control mission equipment concepts are postulated; and ancillary equipment required for delivery and on-orbit servicing interfaces with geosynchronous platforms is grossly defined. The general approach was to develop a platform concept capable of evolving through three on-orbit servicing modes: remote, EVA, and shirtsleeve. The definition of the equipment is to the assembly level. Weight, power, and volumetric data are compiled for all the platforms.
Arjunon, Sivakkumar; Ardana, Pablo Hidalgo; Saikrishnan, Neelakantan; Madhani, Shalv; Foster, Brent; Glezer, Ari; Yoganathan, Ajit P
2015-04-01
Due to expensive nature of clinical trials, implantable cardiac devices should first be extensively characterized in vitro. Prosthetic heart valves (PHVs), an important class of these devices, have been shown to be associated with thromboembolic complications. Although various in vitro systems have been designed to quantify blood-cell damage and platelet activation caused by nonphysiological hemodynamic shear stresses in these PHVs, very few systems attempt to characterize both blood damage and fluid dynamics aspects of PHVs in the same test system. Various numerical modeling methodologies are also evolving to simulate the structural mechanics, fluid mechanics, and blood damage aspects of these devices. This article presents a completely hemocompatible small-volume test-platform that can be used for thrombogenicity studies and experimental fluid mechanics characterization. Using a programmable piston pump to drive freshly drawn human blood inside a cylindrical column, the presented system can simulate various physiological and pathophysiological conditions in testing PHVs. The system includes a modular device-mounting chamber, and in this presented case, a 23 mm St. Jude Medical (SJM) Regents® mechanical heart valve (MHV) in aortic position was used as the test device. The system was validated for its capability to quantify blood damage by measuring blood damage induced by the tester itself (using freshly drawn whole human blood). Blood damage levels were ascertained through clinically relevant assays on human blood while fluid dynamics were characterized using time-resolved particle image velocimetry (PIV) using a blood-mimicking fluid. Blood damage induced by the tester itself, assessed through Thrombin-anti-Thrombin (TAT), Prothrombin factor 1.2 (PF1.2), and hemolysis (Drabkins assay), was within clinically accepted levels. The hydrodynamic performance of the tester showed consistent, repeatable physiological pressure and flow conditions. In addition, the system contains proximity sensors to accurately capture leaflet motion during the entire cardiac cycle. The PIV results showed skewing of the leakage jet, caused by the asymmetric closing of the two leaflets. All these results are critical to characterizing the blood damage and fluid dynamics characteristics of the SJM Regents® MHV, proving the utility of this tester as a precise system for assessing the hemodynamics and thrombogenicity for various PHVs.
Defining Assessment Literacy: Is it Different for Language Testers and Non-Language Testers?
ERIC Educational Resources Information Center
Jeong, Heejeong
2013-01-01
Language assessment courses (LACs) are taught by professionals who have majored in the area of language testing (language testers or LTs), but also by others who come from different language-related majors (non-language testers, non-LTs). Different language assessment courses may be developed, depending on who teaches the course and the…
NASA Astrophysics Data System (ADS)
Guntheroth, Kurt
It is noted that board makers invest considerable time and money writing extensive self-tests and that this investment can be multiplied by selecting ATE (automatic test equipment) that complements and extends the power of the self-test. The tester can diagnose boards in situations where a fault prevents the self-test from running. If the tester monitors such resources as processor, memory, and I/O, confidence in test results is improved. The tester can be used during development of the self-test and to turn on prototypes before the self-test is complete. The author argues that emulative functional testers outperform other types of ATE on boards with BIST (built-in self-test) and lists features of emulative functional testers that are most important to users of BIST.
A detachable mobile and adjustable telemetry system
Parker, Tommy S; Persons, William E; Bradley, Joseph G; Gregg, Margaret; Gonzales, Shinelle K; Helton, Jesse S
2013-01-01
Many traditional mobile telemetry systems require permanently mounting a rod through the cabin of a vehicle to serve as the mast for a directional antenna. In this article we present an alternative to this configuration by providing a platform that can be placed atop the vehicle in which the antenna mast can be mounted and controlled from the cabin of the vehicle. Thereby making this design a viable option for researchers who share vehicles with others that may not approve of permanent vehicle modifications such as placing a hole in the roof of the vehicle as required by traditional mobile configurations. We tested the precision and accuracy of detachable mobile and adjustable telemetry system (DMATS) in an urban park with varying terrain, tree stands, overhead wires, and other structures that can contribute to signal deflection. We placed three radiocollars 50 m apart and 1.2 m above the ground then established three testing stations ∼280 m from the location of the radiocollars. The DMATS platform required 12 h for completion and cost $1059 USD. Four technicians were randomly assigned radio collars to triangulate using DMATS and a handheld telemetry system. We used a one-way analysis of variance (ANOVA) with a Scheffe post hoc test to compare error ellipses between azimuths taken using DMATS and the hand held system. Average error ellipses for all testers was 1.96 ± 1.22 ha. No significant differences were found between error ellipses of testers (P = 0.292). Our design, the DMATS, does not require any vehicle modification; thereby, making this a viable option for researchers sharing vehicles with others that may not approve of permanent vehicle alterations. PMID:23919133
NASA Astrophysics Data System (ADS)
Haji Musa, A. Binti; Malengier, B.; Van Langenhove, L.; Stevens, C.
2017-10-01
A new automated bending tester was developed in Ghent University, Belgium to reduce the human interference in the bending measurement. This paper reports the investigations made on the tester in order to confirm the reliability of its measurement. For that, 11 types of fabrics with different construction parameters were tested for their bending length and flexural rigidity using the new bending tester and the results were compared with that of the standard or manual bending tester, which were conducted in accordance with BS 3356:1990 standard method. Statistical analysis confirms that both measurements are strongly correlated with Pearson’s R≥ 0.90 for all the measurements made. It means that the results from the new automated tester show good correlations with the standard measurement. Nevertheless, this prototype version of the new tester still needs to be adjusted to optimise the functionality of it and further investigations should be done to justify the robustness of the results.
Bassett, I V; Regan, S; Luthuli, P; Mbonambi, H; Bearnot, B; Pendleton, A; Robine, M; Mukuvisi, D; Thulare, H; Walensky, R P; Freedberg, K A; Losina, E; Mhlongo, B
2014-07-01
The aim of the study was to assess HIV prevalence, disease stage and linkage to HIV care following diagnosis at a mobile HIV testing unit, compared with results for clinic-based testing, in a Durban township. This was a prospective cohort study. We enrolled adults presenting for HIV testing at a community-based mobile testing unit (mobile testers) and at an HIV clinic (clinic testers) serving the same area. Testers diagnosed with HIV infection, regardless of testing site, were offered immediate CD4 testing and instructed to retrieve results at the clinic. We assessed rates of linkage to care, defined as CD4 result retrieval within 90 days of HIV diagnosis and/or completion of antiretroviral therapy (ART) literacy training, for mobile vs. clinic testers. From July to November 2011, 6957 subjects were HIV tested (4703 mobile and 2254 clinic); 55% were female. Mobile testers had a lower HIV prevalence than clinic testers (10% vs. 36%, respectively), were younger (median 23 vs. 27 years, respectively) and were more likely to live >5 km or >30 min from the clinic (64% vs. 40%, respectively; all P < 0.001). Mobile testers were less likely to undergo CD4 testing (33% vs. 83%, respectively) but more likely to have higher CD4 counts [median (interquartile range) 416 (287-587) cells/μL vs. 285 (136-482) cells/μL, respectively] than clinic testers (both P < 0.001). Of those who tested HIV positive, 10% of mobile testers linked to care, vs. 72% of clinic testers (P < 0.001). Mobile HIV testing reaches people who are younger, who are more geographically remote, and who have earlier disease compared with clinic-based testing. Fewer mobile testers underwent CD4 testing and linked to HIV care. Enhancing linkage efforts may improve the impact of mobile testing for those with early HIV disease. © 2013 British HIV Association.
21 CFR 872.1720 - Pulp tester.
Code of Federal Regulations, 2011 CFR
2011-04-01
... DENTAL DEVICES Diagnostic Devices § 872.1720 Pulp tester. (a) Identification. A pulp tester is an AC or... current transmitted by an electrode to stimulate the nerve tissue in the dental pulp. (b) Classification...
21 CFR 872.1720 - Pulp tester.
Code of Federal Regulations, 2014 CFR
2014-04-01
... DENTAL DEVICES Diagnostic Devices § 872.1720 Pulp tester. (a) Identification. A pulp tester is an AC or... current transmitted by an electrode to stimulate the nerve tissue in the dental pulp. (b) Classification...
NASA Technical Reports Server (NTRS)
Pohlchuck, Bobby; Zeller, Mary V.
1992-01-01
The adhesive bond between ceramic cement and a titanium matrix composite substrate to be used in the National Aerospace Plane program is evaluated. Two commercially available adhesion testers, the Sebastian Adherence Tester and the CSEM REVETEST Scratch Tester, are evaluated to determine their suitability for quantitatively measuring adhesion strength. Various thicknesses of cements are applied to several substrates, and bond strengths are determined with both testers. The Sabastian Adherence Tester has provided limited data due to an interference from the sample mounting procedure, and has been shown to be incapable of distinguishing adhesion strength from tensile and shear properties of the cement itself. The data from the scratch tester has been found to be difficult to interpret due to the porosity and hardness of the cement. Recommendations are proposed for a more reliable adhesion test method.
Geostationary platform systems concepts definition study. Volume 2A: Appendixes, book 1
NASA Technical Reports Server (NTRS)
1980-01-01
Appendixes addressing various aspects of a geostationary platform concepts definition study are given. Communication platform traffic requirements, video conferencing forecast, intersatellite link capacity requirements, link budgets, payload data, payload assignments, and platform synthesis are addressed.
Operating manual for the miniservo-control tester
Rapp, W.L.
1986-01-01
Ever since the implementation of servo-control units (regular and minimodels) with manometers at U. S. Geological Survey streamflow stations, the need for an effective and efficient servo-control unit tester has been paramount among field personnel. In numerous cases, servo-control unit failures were blamed on battery failures and vice versa. There was no valid instrument to definitively identify cause of failure, let alone properly diagnose the servo-control/manometer system. In 1983, two servo-control unit testers were developed and fabricated. One was mechanical in fabrication, operation, and serviceability; the other was electronic. The testers were extensively used and evaluated in Maine, Ohio, Kansas, and Louisiana under a wide range of environmental conditions. The consensus to integrate the best aspects of both testers into one instrument allowed the Survey to finally solve its long-time need for an effective, efficient servo-control unit tester. (USGS)
1982-01-01
McDornel Douglas performed an Evolutionary Space Platform Concept Study for the Marshall Space Flight Center in the early 1980's. The 10-month study was designed to define, evaluate, and compare approaches and concepts for evolving unmanned and manned capability platforms beyond the then current space platform concepts to an evolutionary goal of establishing a permanent-manned presence in space.
77 FR 30555 - Petitions for Modification of Application of Existing Mandatory Safety Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-23
..., oscilloscopes, vibration analysis machines, insulation testers (meggers), and cable fault detectors (impulse... temperature probes; infrared temperature devices and recorders; insulation testers (meggers); voltage, current..., vibration analysis machines, insulation testers (meggers), and cable fault detectors (impulse generators and...
Geostationary platform systems concepts definition study. Volume 2: Technical, book 1
NASA Technical Reports Server (NTRS)
1980-01-01
The initial selection and definition of operational geostationary platform concepts is discussed. Candidate geostationary platform missions and payloads were identified from COMSAT, Aerospace, and NASA studies. These missions and payloads were cataloged; classified with to communications, military, or scientific uses; screened for application and compatibility with geostationary platforms; and analyzed to identify platform requirements. Two platform locations were then selected (Western Hemisphere - 110 deg W, and Atlantic - 15 deg W), and payloads allocated based on nominal and high traffic models. Trade studies were performed leading to recommendation of selected concepts. Of 30 Orbit Transfer Vehicle (0TV) configuration and operating mode options identified, 18 viable candidates compatible with the operational geostationary platform missions were selected for analysis. Each was considered using four platform operational modes - 8 or 16 year life, and serviced or nonserviced, providing a total of 72 OTV/platform-mode options. For final trade study concept selection, a cost program was developed considering payload and platform costs and weight; transportation unit and total costs for the shuttle and OTV; and operational costs such as assembly or construction time, mating time, and loiter time. Servicing costs were added for final analysis and recommended selection.
Development of deployable structures for large space platform systems, volume 1
NASA Technical Reports Server (NTRS)
1982-01-01
Generic deployable spacecraft configurations and deployable platform systems concepts were identified. Sizing, building block concepts, orbiter packaging, thermal analysis, cost analysis, and mass properties analysis as related to platform systems integration are considered. Technology needs are examined and the major criteria used in concept selection are delineated. Requirements for deployable habitat modules, tunnels, and OTV hangars are considered.
NASA Technical Reports Server (NTRS)
Tellier, G. F.
1973-01-01
Tester investigates fundamental factors affecting cyclic life and sealing performance of valve seats and poppets. Tester provides for varying impact loading of poppet against seat and rate of cycling, and controls amount and type of relative motion between sealing faces of seat and poppet. Relative motion between seat and poppet can be varied in three modes.
49 CFR Appendix F to Part 240 - Medical Standards Guidelines
Code of Federal Regulations, 2010 CFR
2010-10-01
... greater guidance on the procedures that should be employed in administering the vision and hearing... more errors on plates 1-15. MULTIFUNCTION VISION TESTER Keystone Orthoscope Any error. OPTEC 2000 Any error. Titmus Vision Tester Any error. Titmus II Vision Tester Any error. (3) In administering any of...
49 CFR Appendix F to Part 240 - Medical Standards Guidelines
Code of Federal Regulations, 2011 CFR
2011-10-01
... greater guidance on the procedures that should be employed in administering the vision and hearing... more errors on plates 1-15. MULTIFUNCTION VISION TESTER Keystone Orthoscope Any error. OPTEC 2000 Any error. Titmus Vision Tester Any error. Titmus II Vision Tester Any error. (3) In administering any of...
A reliability study of the new sensors for movement analysis (SHARIF-HMIS).
Abedi, Mohen; Manshadi, Farideh Dehghan; Zavieh, Minoo Khalkhali; Ashouri, Sajad; Azimi, Hadi; Parnanpour, Mohamad
2016-04-01
SHARIF-HMIS is a new inertial sensor designed for movement analysis. The aim of the present study was to assess the inter-tester and intra-tester reliability of some kinematic parameters in different lumbar motions making use of this sensor. 24 healthy persons and 28 patients with low back pain participated in the current reliability study. The test was performed in five different lumbar motions consisting of lumbar flexion in 0, 15, and 30° in the right and left directions. For measuring inter-tester reliability, all the tests were carried out twice on the same day separately by two physiotherapists. Intra-tester reliability was assessed by reproducing the tests after 3 days by the same physiotherapist. The present study revealed satisfactory inter- and intra-tester reliability indices in different positions. ICCs for intra-tester reliability ranged from 0.65 to 0.98 and 0.59 to 0.81 for healthy and patient participants, respectively. Also, ICCs for inter-tester reliability ranged from 0.65 to 0.92 for the healthy and 0.65 to 0.87 for patient participants. In general, it can be inferred from the results that measuring the kinematic parameters in lumbar movements using inertial sensors enjoys acceptable reliability. Copyright © 2015 Elsevier Ltd. All rights reserved.
Geostationary platform systems concepts definition study. Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
1980-01-01
The results of a geostationary platform concept analysis are summarized. Mission and payloads definition, concept selection, the requirements of an experimental platform, supporting research and technology, and the Space Transportation System interface requirements are addressed. It is concluded that platforms represent a logical extension of current trends toward larger, more complex, multifrequency satellites. Geostationary platforms offer significant cost savings compared to individual satellites, with the majority of these economies being realized with single Shuttle launched platforms. Further cost savings can be realized, however, by having larger platforms. Platforms accommodating communications equipment that operates at multiple frequencies and which provide larger scale frequency reuse through the use of large aperture multibeam antennas and onboard switching maximize the useful capacity of the orbital arc and frequency spectrum. Projections of market demand indicate that such conservation measures are clearly essential if orderly growth is to be provided for. In addition, it is pointed out that a NASA experimental platform is required to demonstrate the technologies necessary for operational geostationary platforms of the 1990's.
21 CFR 872.1730 - Electrode gel for pulp testers.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electrode gel for pulp testers. 872.1730 Section 872.1730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1730 Electrode gel for pulp testers. (a...
21 CFR 872.1730 - Electrode gel for pulp testers.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Electrode gel for pulp testers. 872.1730 Section 872.1730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1730 Electrode gel for pulp testers. (a...
NASA Technical Reports Server (NTRS)
Lee, Jason H.
2011-01-01
Cables are very important electrical devices that carry power and signals across multiple instruments. Any fault in a cable can easily result in a catastrophic outcome. Therefore, verifying that all cables are built to spec is a very important part of Electrical Integration Procedures. Currently, there are two methods used in lab for verifying cable connectivity. (1) Using a Break-Out Box and an ohmmeter this method is time-consuming but effective for custom cables and (2) Commercial Automated Cable Tester Boxes this method is fast, but to test custom cables often requires pre-programmed configuration files, and cables used on spacecraft are often uniquely designed for specific purposes. The idea is to develop a semi-automatic continuity tester that reduces human effort in cable testing, speeds up the electrical integration process, and ensures system safety. The JPL-Cable Tester Box is developed to check every single possible electrical connection in a cable in parallel. This system indicates connectivity through LED (light emitting diode) circuits. Users can choose to test any pin/shell (test node) with a single push of a button, and any other nodes that are shorted to the test node, even if they are in the same connector, will light up with the test node. The JPL-Cable Tester Boxes offers the following advantages: 1. Easy to use: The architecture is simple enough that it only takes 5 minutes for anyone to learn how operate the Cable Tester Box. No pre-programming and calibration are required, since this box only checks continuity. 2. Fast: The cable tester box checks all the possible electrical connections in parallel at a push of a button. If a cable normally takes half an hour to test, using the Cable Tester Box will improve the speed to as little as 60 seconds to complete. 3. Versatile: Multiple cable tester boxes can be used together. As long as all the boxes share the same electrical potential, any number of connectors can be tested together.
Product-Improvement Test (Phase II), Jetcal Tester, Model H119A.
1969-03-05
Ao—A0 51 113 ARMY AVIATION ‘Cs’ BOARD FORT tUCKER ALA — P*OOUCTeII ROVEMCNT TEST ( FHAS ~ I I ) . JETCAL TESTER, MODEL M119A~~’ETC(U) MAR S9...Phase i i ) , Jetcal Tester , Model H 119A , USATECOM Project No. 4-6-5011-03 b . No fur ther consideration be given to the TEMPCAL heater probe as a...essen t i a l component of the Jetcal Tester. e. The service manual instruct ions for con t inu i ty te s t ing of EG1 thermocouples be revised to
Thorborg, K; Bandholm, T; Schick, M; Jensen, J; Hölmich, P
2013-08-01
Handheld dynamometry (HHD) is a promising tool for obtaining reliable hip strength measurements in the clinical setting, but intertester reliability has been questioned, especially in situations where testers exhibit differences in upper-extremity muscle strength (male vs female). The purpose of this study was to examine the intertester reliability concerning strength assessments of hip abduction, adduction, external and internal rotation, flexion and extension using HHD, and to test whether systematic differences in test values exist between testers of different upper-extremity strength. Fifty healthy individuals (29 women), aged 25 ± 5 years were included. Two physiotherapist students (one female, one male) of different upper-extremity strength performed the measurements. The tester order and strength test order were randomized. Intraclass correlation coefficients were used to quantify reliability, and ranged from 0.82 to 0.91 for the six strength test. The female tester systematically measured lower strength values for all isometric strength tests (P < 0.05). In hip strength assessments using HHD, systematic bias exists between testers of different sex, which is likely explained by differences in upper-extremity strength. Hence, to improve intertester reliability, the dynamometer likely needs external fixation, as this will eliminate the influence of differences in upper-extremity strength between testers. © 2011 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
16 CFR Figure 3 to Subpart A of... - Flooring Radiant Tester Schematic Side Elevation
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Flooring Radiant Tester Schematic Side Elevation 3 Figure 3 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 1209, Subpt. A, Fig. 3 Figure 3 to Subpart A of Part 1209—Flooring Radiant Tester Schematic Side...
16 CFR Figure 3 to Subpart A of... - Flooring Radiant Tester Schematic Side Elevation
Code of Federal Regulations, 2014 CFR
2014-01-01
... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Flooring Radiant Tester Schematic Side Elevation 3 Figure 3 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 1209, Subpt. A, Fig. 3 Figure 3 to Subpart A of Part 1209—Flooring Radiant Tester Schematic Side...
16 CFR Figure 3 to Subpart A of... - Flooring Radiant Tester Schematic Side Elevation
Code of Federal Regulations, 2013 CFR
2013-01-01
... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Flooring Radiant Tester Schematic Side Elevation 3 Figure 3 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 1209, Subpt. A, Fig. 3 Figure 3 to Subpart A of Part 1209—Flooring Radiant Tester Schematic Side...
16 CFR Figure 3 to Subpart A of... - Flooring Radiant Tester Schematic Side Elevation
Code of Federal Regulations, 2012 CFR
2012-01-01
... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Flooring Radiant Tester Schematic Side Elevation 3 Figure 3 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 1209, Subpt. A, Fig. 3 Figure 3 to Subpart A of Part 1209—Flooring Radiant Tester Schematic Side...
16 CFR Figure 3 to Subpart A of... - Flooring Radiant Tester Schematic Side Elevation
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Flooring Radiant Tester Schematic Side Elevation 3 Figure 3 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 1209, Subpt. A, Fig. 3 Figure 3 to Subpart A of Part 1209—Flooring Radiant Tester Schematic Side...
General Purpose Vehicle Mechanic Career Ladder, AFSCs 47232, 47252, and 47275.
1983-03-01
general-purpose vehicles; gasoline and diesel engines; automotive electrical and emission control systems maintenance; drive trains and brake systems...OR HYDRAULIC PRESSES ELECTRONIC IGNITION TESTERS HEADLIGHT TESTERS OSCILLOSCOPES DYNAMOMETERS EXHAUST EMISSION TESTERS GAS SHIELD WELDING...collection forms; man-hour accounting forms and reports; corrosion control procedures; troubleshooting exhaust systems, and emission control systems
Design summary of a geostationary facility utilized as a communications platform
NASA Technical Reports Server (NTRS)
Barberis, N. J.; Brown, J. V.
1986-01-01
This paper describes the technical aspects of a geostationary platform facility that makes maximum use of the planned NASA space station and its elements, mainly the orbital maneuvering vehicle (OMV) and the orbital transfer vehicles (OTV). The platform design concept is described, with emphasis on the key technologies utilized to configure the platform. Key systems aspects include a design summary with discussion of the controls, telemetry, command and ranging, power, propulsion, control electronics, thermal control subsystems, and space station interfaces. The use of the facility as a communications platform is developed to demonstrate the attractiveness of the concept. The economic benefits are discussed, as well as the concept of servicing for payload upgrade.
A Cheap, Semiquantitative Hand-Held Conductivity Tester.
ERIC Educational Resources Information Center
Zawacky, Susan K. S.
1995-01-01
Describes a design for a hand-held conductivity tester powered by a 9V battery that gives semi-quantitative results for aqueous electrolyte solutions of concentrations ranging from 0.001 M to 0.1 M. The tester uses a bar-graph LED driven by an LM3914 integrated circuit to indicate the level of conductivity. A list of parts, procedures, and results…
DOT National Transportation Integrated Search
2013-03-01
This report covers the evaluation of the Hamburg Loaded Wheel Rut Tester (OHD L-55) and the : Moisture Induced Stress Tester (MIST) for field control of Oklahoma HMA mixtures. OHD L-55 : was evaluated as a possible replacement for AASHTO T 283 and fo...
16 CFR Figure 4 to Subpart A of... - Flooring Radiant Panel Tester Schematic Low Flux End, Elevation
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Flooring Radiant Panel Tester Schematic Low Flux End, Elevation 4 Figure 4 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY... Standard Pt. 1209, Subpt. A, Fig. 4 Figure 4 to Subpart A of Part 1209—Flooring Radiant Panel Tester...
NASA Astrophysics Data System (ADS)
McKenzie, Neil
1989-12-01
We present a design for a low-cost, functional VLSI chip tester. It is based on the Apple MacIntosh II personal computer. It tests chips that have up to 128 pins. All pin drivers of the tester are bidirectional; each pin is programmed independently as an input or an output. The tester can test both static and dynamic chips. Rudimentary speed testing is provided. Chips are tested by executing C programs written by the user. A software library is provided for program development. Tests run under both the Mac Operating System and A/UX. The design is implemented using Xilinx Logic Cell Arrays. Price/performance tradeoffs are discussed.
Kondo, Keita; Niwa, Toshiyuki; Danjo, Kazumi
2012-01-01
This report describes a new disintegration tester that can determine not only the disintegration time of orally rapidly disintegrating tablets (ODT), but also the disintegration behavior and mechanism. Using the tester, the disintegration properties of the tablets prepared in a previous study were examined. The purpose of this study is to confirm the utility of the tester as an instrument for evaluating the disintegration properties of ODT and determine relations among time, behavior and mechanism of the disintegration. Results demonstrated that in vitro disintegration time in the tester is similar to that in the commercial disintegration tester for ODT and is highly correlated with oral disintegration time. Observations of disintegration process revealed that a difference in disintegration behavior between tablets compressed at 50-75 MPa and 100 MPa; the disintegration behavior of the tablets were designated immediate disintegrating type and gradual disintegrating type, respectively. The dynamic swelling profile and water absorption profile indicated that the disintegration mechanism of the tablets involved wicking action induced by swelling of the disintegrant; the disintegration time was closely related to the initial rates of swelling and water absorption. Furthermore, the mechanism of water absorption of tablets compressed at 50-75 MPa and 100 MPa shows anomalous diffusion and case-II transport, respectively. The shift in this mechanism is consistent with differences in disintegration time and behavior between the tablets. These findings suggest that information on disintegration properties obtained by our tester is useful for understanding of disintegration phenomena of ODT.
A new family of omnidirectional and holonomic wheeled platforms for mobile robots
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pin, F.G.; Killough, S.M.
1994-08-01
This paper presents the concepts for a new family of holonomic wheeled platforms that feature full omnidirectionality with simultaneous and independently controlled rotational and translational motion capabilities. The authors first present the orthogonal-wheels'' concept and the two major wheel assemblies on which these platforms are based. The authors then describe how a combination of these assemblies with appropriate control can be used to generate an omnidirectional capability for mobile robot platforms. Several alternative designs are considered, and their respective characteristics with respect to rotational and translational motion control are discussed. The design and control of a prototype platform developed tomore » test and demonstrate the proposed concepts is then described, and experimental results illustrating the full omnidirectionality of the platforms with decoupled rotational and translational degrees of freedom are presented.« less
Hand-Drawn Resistors and a Simple Tester Using a Light-Emitting Diode
ERIC Educational Resources Information Center
Kamata, Masahiro; Abe, Mayumi
2012-01-01
A thick line drawn on a sheet of paper with a 6B pencil is electrically conductive and its resistance can be roughly estimated using a simple tester made of a light-emitting diode (LED) and a lithium coin-type cell. Using this hand-drawn resistor and the LED tester, we developed teaching materials that help students to understand how electrical…
Efficient clinical evaluation of guideline quality: development and testing of a new tool
2014-01-01
Background Evaluating the methodological quality of clinical practice guidelines is essential before deciding which ones which could best inform policy or practice. One current method of evaluating clinical guideline quality is the research-focused AGREE II instrument. This uses 23 questions scored 1–7, arranged in six domains, which requires at least two independent testers, and uses a formulaic weighted domain scoring system. Following feedback from time-poor clinicians, policy-makers and managers that this instrument did not suit clinical need, we developed and tested a simpler, shorter, binary scored instrument (the iCAHE Guideline Quality Checklist) designed for single users. Methods Content and construct validity, inter-tester reliability and clinical utility were tested by comparing the new iCAHE Guideline Quality Checklist with the AGREE II instrument. Firstly the questions and domains in both instruments were compared. Six randomly-selected guidelines on a similar theme were then assessed by three independent testers with different experience in guideline quality assessment, using both instruments. Per guideline, weighted domain and total AGREE II scores were calculated, using the scoring rubric for three testers. Total iCAHE scores were calculated per guideline, per tester. The linear relationship between iCAHE and AGREE II scores was assessed using Pearson r correlation coefficients. Score differences between testers were assessed for the iCAHE Guideline Quality Checklist. Results There were congruent questions in each instrument in four domains (Scope & Purpose, Stakeholder involvement, Underlying evidence/Rigour, Clarity). The iCAHE and AGREE II scores were moderate to strongly correlated for the six guidelines. There was generally good agreement between testers for iCAHE scores, irrespective of their experience. The iCAHE instrument was preferred by all testers, and took significantly less time to administer than the AGREE II instrument. However, the use of only three testers and six guidelines compromised study power, rendering this research as pilot investigations of the psychometric properties of the iCAHE instrument. Conclusion The iCAHE Guideline Quality Checklist has promising psychometric properties and clinical utility. PMID:24885893
Seidel, G; Münch, I; Dreier, M; Borutta, B; Walter, U; Dierks, M-L
2014-03-01
Evidence-based patient information is an essential part of decision making in health issues. A qualitative study was conducted to examine whether consumers consider the health information on colorectal cancer screening in Germany helpful in supporting their decision making. In this study, eight texts from different German authors about colorectal cancer screening were evaluated with a criteria-based selection. The texts were tested for understandability, structure, design, and effect on readers. Thirteen semi-structured focus groups were formed including 59 higher-educated and 15 lower-educated testers, 46 % of them being male with a mean age of 62.9 years. The transcripts were analyzed by content-analytic assessment. The testers provided detailed comments on the content and design of the texts. They revealed inaccuracies and suggested improvements of the texts. The testers differed from each other in terms of the intensity of their participation in the discussions and comprehension of the material. The reception of the flyers and brochures varied according to the educational level of the testers. Lower-educated testers often skipped passages of texts about risks as well as passages containing numbers and graphics. The texts had different effects on the testers, regardless of the level of education. If adverse effects were presented, some testers became scared while others were reassured because they felt informed. Most of the testers appreciated a call for participation as a central message of the text. Sometimes, if there was no clear appeal to attend the screening, the testers even asked for it. The recently introduced political strategy of promoting an informed choice is applied to an unprepared population who was used to getting a clear yes-or-no recommendation. Thus, at first, the population has to learn how to make an informed choice. This topic must be addressed and taken into account in the process of developing health information. Since this is not always the case, we conclude that current materials are limited in their contribution toward the decision of attending CRC screening.
Sayed, Shahin; Lester, Susan C; Wilson, Michael; Berney, Daniel; Masia, Ricard; Moloo, Zahir; Stall, Jennifer; Eslan, Alexia; Ayers, Stephanie; Mutuku, Angela; Guarner, Jeannette
2017-01-01
Case-based learning (CBL) is an established pedagogical active learning method used in various disciplines and defined based on the field of study and type of case. The utility of CBL for teaching specific aspects of cancer diagnosis to practising pathologists has not been previously studied in sub-Saharan Africa. We aimed to pilot test standardised cancer cases on a group of practising pathologists in sub-Saharan Africa to evaluate case content, clarity of questions and delivery of content. Expert faculty created cases for the four most commonly diagnosed cancers. The format included mini-cases and bullet cases which were all open-ended. The questions dealt with interpretation of clinical information, gross specimen examination, morphologic characteristics of tumours, ancillary testing, reporting and appropriate communication to clinicians. Cases on breast, cervical, prostate and colorectal cancers were tested on seven practising pathologists. Each case took an average of 45-90 min to complete.Questions that were particularly challenging to testers were on: Specimens they should have been but for some reason were not exposed to in routine practice.Ancillary testing and appropriate tumour staging.New knowledge gained included tumour grading and assessment of radial margins. Revisions to cases were made based on testers' feedback, which included rewording of questions to reduce ambiguity and adding of tables to clarify concepts. Cases were created for CBL in Kenya, but these are applicable elsewhere in Africa and beyond to teach cancer diagnosis. The pilot testing of cases prepared faculty for the actual CBL course and feedback provided by the testers assisted in improving the questions and impact on day-to-day practice.
Riach, Anna C; Asquith, Rachel; Fallon, Melissa L D
2017-09-01
Domestic dogs (Canis familiaris) use urine to communicate among themselves, however, it is unknown whether the gonadectomy (neutering or spaying) of a dog affects this communication in anyway. Urine samples from 10 intact and 10 gonadectomised, unfamiliar dogs were presented to 12 tester dogs to sniff under controlled conditions in a pilot study. The amount of time the tester dogs spent sniffing each sample was recorded. Overall, tester dogs were recorded smelling the urine of gonadectomised individuals for a longer time. In addition to the type of urine sample, the result is likely to have been influenced by the sex and status (gonadectomised or intact) of the tester dogs. The observed increase in the length of time spent sniffing urine from gonadectomised individuals could be explained by the tester dogs experiencing more difficulty in gaining information from the urine or facing more confusion while analysing the urine compared to the intact urine they have evolved to smell. Copyright © 2017 Elsevier B.V. All rights reserved.
Space platform utilities distribution study
NASA Technical Reports Server (NTRS)
Lefever, A. E.
1980-01-01
Generic concepts for the installation of power data and thermal fluid distribution lines on large space platforms were discussed. Connections with central utility subsystem modules and pallet interfaces were also considered. Three system concept study platforms were used as basepoints for the detail development. The tradeoff of high voltage low voltage power distribution and the impact of fiber optics as a data distribution mechanism were analyzed. Thermal expansion and temperature control of utility lines and ducts were considered. Technology developments required for implementation of the generic distribution concepts were identified.
NASA Technical Reports Server (NTRS)
Hawkins, L. A.; Murphy, Brian T.; Lang, K. W.
1991-01-01
The operation of the magnetic bearing used as an excitation source in the Rocketdyne Multifunction Tester is described. The tester is scheduled for operation during the summer of 1990. The magnetic bearing can be used in two control modes: (1) open loop mode, in which the magnetic bearing operates as a force actuator; and (2) closed loop mode, in which the magnetic bearing provides shaft support. Either control mode can be used to excite the shaft; however, response of the shaft in the two control modes is different due to the alteration of the eigenvalues by closed loop mode operation. A rotordynamic model is developed to predict the frequency response of the tester due to excitation in either control mode. Closed loop mode excitation is shown to be similar to the excitation produced by a rotating eccentricity in a conventional bearing. Predicted frequency response of the tester in the two control modes is compared, and the maximum response is shown to be the same for the two control modes when synchronous unbalance loading is not considered. The analysis shows that the response of this tester is adequate for the extraction of rotordynamic stiffness, damping, and inertia coefficients over a wide range of test article stiffnesses.
HIV impact on women: gender difference among late testers and advanced HIV infection
NASA Astrophysics Data System (ADS)
Sukmawati, N. M. D. D.; Merati, T. P.; Somia, A.; Utama, S.; Gayatri, Y.
2018-03-01
This study reported the effect of gender difference on HIV seropositive late testers or advanced infection. A retrospective cohort study of newly diagnosed HIV seropositive based on adatabase in the main referral hospital in Denpasar, Bali, Indonesia from 2004 – 2016. Women and man were categorized as late testers (CD4 ≤ 200 cells/uL and/or AIDS diagnosis ≤ 12 months from first HIV test date). Non-late testers (CD4 > 200 cells/uL and/or no AIDS diagnosis during study period or diagnosis of AIDS >12 months from HIV diagnosis), of reproductive age (13 – 49 years old), and not of reproductive age (>49 years old). Logistic regression was used to estimate risk and its statistical significance. The model consists of gender and age correctly classified 83.5% of cases. Women were almost two times more likely to present as non-late testers compared to men, and reproductive age of 15 – 49 years were 1.5 times more likely to present as non-late testers compared to those with age > 49 years. Women affected by HIV almost in equal as for men. Women and those within reproductive age were more likely to present before the advanced stage compared to men and those aged > 49 years.
Wollin, Martin; Purdam, Craig; Drew, Michael K
2016-01-01
To investigate inter and intra-tester reliability of an externally fixed dynamometry unilateral hamstring strength test, in the elite sports setting. Reliability study. Sixteen, injury-free, elite male youth football players (age=16.81±0.54 years, height=180.22±5.29cm, weight 73.88±6.54kg, BMI=22.57±1.42) gave written informed consent. Unilateral maximum isometric peak hamstring force was evaluated by externally fixed dynamometry for inter-tester, intra-day and intra-tester, inter-week reliability. The test position was standardised to correlate with the terminal swing phase of the gait running cycle. Inter and intra-tester values demonstrated good to high levels of reliability. The intra-class coefficient (ICC) for inter-tester, intra-day reliability was 0.87 (95% CI=0.75-0.93) with standard error of measure percentage (SEM%) 4.7 and minimal detectable change percentage (MDC%) 12.9. Intra-tester, inter-week reliability results were ICC 0.86 (95% CI, 0.74-0.93), SEM% 5.0 and MDC% 14.0. This study demonstrates good to high inter and intra-tester reliability of isometric externally fixed dynamometry unilateral hamstring strength testing in the regular elite sport setting involving elite male youth football players. The intra-class coefficient in association with the low standard error of measure and minimal detectable change percentages suggest that this procedure is appropriate for clinical and academic use as well as monitoring hamstring strength in the elite sport setting. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.
Gianquinto, Giorgio; Fecondini, Marco; Mezzetti, Mirco; Orsini, Francesco
2010-02-01
Farming is considered one of the main causes of land degradation and underground water pollution. The increased availability of agricultural inputs has led to a dramatic rise in yields, which has resulted in soil fertility spoilage and overuse of fertilisers. Therefore horticultural practice improvement must consider appropriate nitrogen (N) management. This paper reports results on the application of an optical diagnostic system (N-tester) to guide N fertilisation in muskmelon (Cucumis melo L.) over a 3 year trial. Results on fresh and postharvest quality are also presented. Fertilisation events mirrored increases in N-tester values during the season, and a significant linear relationship (R(2) = 0.628) was observed between N-tester readings and leaf chlorophyll content. The N-tester-guided fertilisation treatments were characterised by yields comparable to the control, but with significantly lower applications of N (down to 17-66% of the N distributed in the control). Moreover, the N-tester treatments yielded fruits with higher sugar content. This was also true after storage, when N-tester fruits also showed reduced weight loss associated with lower transpiration and ethylene emission rates. Through the use of 'spy plots' kept at optimal nutritional status and the adoption of a threshold for N application throughout the growing cycle of muskmelon, the N supply was significantly reduced. Therefore a correct application of N-tester allowed the plant N requirement to be reduced and the fruit sugar content and storability to be increased without adversely affecting the yield.
Test-retest reliability of myofascial trigger point detection in hip and thigh areas.
Rozenfeld, E; Finestone, A S; Moran, U; Damri, E; Kalichman, L
2017-10-01
Myofascial trigger points (MTrP's) are a primary source of pain in patients with musculoskeletal disorders. Nevertheless, they are frequently underdiagnosed. Reliable MTrP palpation is the necessary for their diagnosis and treatment. The few studies that have looked for intra-tester reliability of MTrPs detection in upper body, provide preliminary evidence that MTrP palpation is reliable. Reliability tests for MTrP palpation on the lower limb have not yet been performed. To evaluate inter- and intra-tester reliability of MTrP recognition in hip and thigh muscles. Reliability study. 21 patients (15 males and 6 females, mean age 21.1 years) referred to the physical therapy clinic, 10 with knee or hip pain and 11 with pain in an upper limb, low back, shin or ankle. Two experienced physical therapists performed the examinations, blinded to the subjects' identity, medical condition and results of the previous MTrP evaluation. Each subject was evaluated four times, twice by each examiner in a random order. Dichotomous findings included a palpable taut band, tenderness, referred pain, and relevance of referred pain to patient's complaint. Based on these, diagnosis of latent MTrP's or active MTrP's was established. The evaluation was performed on both legs and included a total of 16 locations in the following muscles: rectus femoris (proximal), vastus medialis (middle and distal), vastus lateralis (middle and distal) and gluteus medius (anterior, posterior and distal). Inter- and intra-tester reliability (Cohen's kappa (κ)) values for single sites ranged from -0.25 to 0.77. Median intra-tester reliability was 0.45 and 0.46 for latent and active MTrP's, and median inter-tester reliability was 0.51 and 0.64 for latent and active MTrPs, respectively. The examination of the distal vastus medialis was most reliable for latent and active MTrP's (intra-tester k = 0.27-0.77, inter-tester k = 0.77 and intra-tester k = 0.53-0.72, inter-tester k = 0.72, correspondingly). Inter- and intra-tester reliability of active and latent MTrP evaluation was moderate to substantial. Palpation evaluation can be used for clinical diagnosis of MTrP's in the hip and thigh muscles. This study provides evidence that MTrP palpation is a moderately reliable diagnostic tool in the hip and thigh muscles and can be used in clinical practice and research. Copyright © 2017 Elsevier Ltd. All rights reserved.
Development of deployable structures for large space platforms. Volume 2: Design development
NASA Technical Reports Server (NTRS)
Greenberg, H. S.
1983-01-01
Design evolution, test article design, test article mass properties, and structural analysis of deployable platform systems are discussed. Orbit transfer vehicle (OTV) hangar development, OTV hangar concept selection, and manned module development are discussed. Deployable platform systems requirements, material data base, technology development needs, concept selection and deployable volume enclosures are also discussed.
NASA Astrophysics Data System (ADS)
Rammage, Robert L.
1990-10-01
A device for sequentially testing the plurality of connectors in a wiring harness is disclosed. The harness is attached to the tester by means of adapter cables and a rotary switch is used to sequentially, individually test the connectors by passing a current through the connector. If the connector is unbroken, a light will flash to show it is electrically sound. The adapters allow a large number of cable configurations to be tested using a single tester configuration.
Online Tester for a Symbol Generator
NASA Technical Reports Server (NTRS)
Juday, D.; Mcconaugy, K.
1985-01-01
About 95 percent of faults detected. Programable instrument periodically checks for failures in system that generates alphanumerical and other symbol voltages for cathode-ray-tube displays. Symbol-generator tester compares gated test-point voltages with predetermined voltage limits while circuit under test performs commanded operation. A go/no-go indication given, depending on whether test voltage is or is not within its specification. Tester in plug-in modular form, temporarily wired to generator test points, or permanently wired to these points.
Gittings, H.T. Jr.; Kalbach, J.F.
1958-01-14
This patent relates to tube testing, and in particular describes a tube tester for automatic testing of a number of vacuum tubes while in service and as frequently as may be desired. In it broadest aspects the tube tester compares a particular tube with a standard tube tarough a difference amplifier. An unbalanced condition in the circuit of the latter produced by excessive deviation of the tube in its characteristics from standard actuates a switch mechanism stopping the testing cycle and indicating the defective tube.
Del Eckels, Joel [Livermore, CA; Nunes, Peter J [Danville, CA; Simpson, Randall L [Livermore, CA; Whipple, Richard E [Livermore, CA; Carter, J Chance [Livermore, CA; Reynolds, John G [San Ramon, CA
2010-08-10
An inspection tester system for testing for explosives. The tester includes a body and a swab unit adapted to be removeably connected to the body. At least one reagent holder and dispenser is operatively connected to the body. The reagent holder and dispenser contains an explosives detecting reagent and is positioned to deliver the explosives detecting reagent to the swab unit. A heater is operatively connected to the body and the swab unit is adapted to be operatively connected to the heater.
The utility of covariance of combining ability in plant breeding.
Arunachalam, V
1976-11-01
The definition of covariances of half- and full sibs, and hence that of variances of general and specific combining ability with regard to a quantitative character, is extended to take into account the respective covariances between a pair of characters. The interpretation of the dispersion and correlation matrices of general and specific combining ability is discussed by considering a set of single, three- and four-way crosses, made using diallel and line × tester mating systems in Pennisetum typhoides. The general implications of the concept of covariance of combining ability in plant breeding are discussed.
Karthikeyan, Veluswamy; Gnanamanickam, S S
2008-10-01
A total of 128 isolates of Setaria-infecting Magnaporthe grisea strains were obtained from different states of South India which includes sampling sites from Tamil Nadu, two from Karnataka, one from Andhra Pradesh and Kerala. Out of the selected 128 isolates 30 strains were tested with MAT1-1 and MAT1-2 fertile standard testers to determine their mating type. None of the 30 Setaria isolates produced perithecia with fertile testers. However, when monoconidial isolates were mated among themselves, isolates from the same field produced only barren perithecia and the tester isolates were able to mate readily with finger millet isolates. This is the first report of the mating-type studies on Setaria infecting Magnaporthe grisea with standard testers. This result indicates that the Setaria infecting population is infertile. In pathogenicity assay, it was found that 9 out of the 22 Setaria accessions were highly susceptible to Setaria strains of the blast fungus and seven cultivars/accessions were resistant to blast pathogen. Various virulence reactions were scored according to Standard Evaluation System.
NASA Technical Reports Server (NTRS)
Medelius, Pedro J. (Inventor); Simpson, Howard J. (Inventor)
1999-01-01
A cable tester is described for low frequency testing of a cable for faults. The tester allows for testing a cable beyond a point where a signal conditioner is installed, minimizing the number of connections which have to be disconnected. A magnetic pickup coil is described for detecting a test signal injected into the cable. A narrow bandpass filter is described for increasing detection of the test signal. The bandpass filter reduces noise so that a high gain amplifier provided for detecting a test signal is not completely saturate by noise. To further increase the accuracy of the cable tester, processing gain is achieved by comparing the signal from the amplifier with at least one reference signal emulating the low frequency input signal injected into the cable. Different processing techniques are described evaluating a detected signal.
LSST system analysis and integration task for an advanced science and application space platform
NASA Technical Reports Server (NTRS)
1980-01-01
To support the development of an advanced science and application space platform (ASASP) requirements of a representative set of payloads requiring large separation distances selected from the Science and Applications Space Platform data base. These payloads were a 100 meter diameter atmospheric gravity wave antenna, a 100 meter by 100 meter particle beam injection experiment, a 2 meter diameter, 18 meter long astrometric telescope, and a 15 meter diameter, 35 meter long large ambient deployable IR telescope. A low earth orbit at 500 km altitude and 56 deg inclination was selected as being the best compromise for meeting payload requirements. Platform subsystems were defined which would support the payload requirements and a physical platform concept was developed. Structural system requirements which included utilities accommodation, interface requirements, and platform strength and stiffness requirements were developed. An attitude control system concept was also described. The resultant ASASP concept was analyzed and technological developments deemed necessary in the area of large space systems were recommended.
Geostationary platform systems concepts definition study. Volume 2: Technical, book 2
NASA Technical Reports Server (NTRS)
1980-01-01
A selected concept for a geostationary platform is defined in sufficient detail to identify requirements for supporting research and technology, space demonstrations, GFE interfaces, costs, and schedules. This system consists of six platforms in geostationary orbit (GEO) over the Western Hemisphere and six over the Atlantic, to satisfy the total payload set associated with the nominal traffic model. Each platform is delivered to low Earth orbit (LEO) in a single shuttle flight, already mated to its LEO to GEO transfer vehicle and ready for deployment and transfer to GEO. An alternative concept is looked at briefly for comparison of configuration and technology requirements. This alternative consists of two large platforms, one over the Western Hemisphere consisting of three docked modules, and one over the Atlantic (two docked modules), to satisfy a high traffic model. The modules are full length orbiter cargo bay payloads, mated at LEO to orbital transfer vehicles (OTVs) delivered in other shuttle flights, for transfer to GEO, rendezvous, and docking. A preliminary feasibility study of an experimental platform is also performed to demonstrate communications and platform technologies required for the operational platforms of the 1990s.
1954-01-01
THE AMERICAN OPTICAL VISION TESTER AND THE ARMED FORCES FAR VISUAL ACUITY TEST Comparisons were made of the visual acuity scores of 100 enlisted men on ...the American Optical Vision Tester (with Sloan plates) and on the Armed Forces Far Visual Acuity test. Order of presentation was: AO-left eye, AO...right eye, AFFVAT-left, AFVTAT-right. Correlation coefficients between AO and AFFVAT were around .89. Dispersion of acuity scores was about the same on
A portable wheel tester for tyre-road friction and rolling resistance determination
NASA Astrophysics Data System (ADS)
Pytka, J.; Budzyński, P.; Tarkowski, P.; Piaskowski, M.
2016-09-01
The paper describes theory of operation, design and construction as well as results from primarily experiments with a portable wheel tester that has been developed by the authors as a device for on-site determination of tyre-road braking/driving friction and rolling resistance. The paper includes schematics, drawings, descriptions as well as graphical results form early tests with the presented device. It is expected that the tester can be useful in road accident reconstruction applications as well as in vehicle dynamics research.
A caregiver support platform within the scope of an ambient assisted living ecosystem.
Costa, Angelo; Novais, Paulo; Simoes, Ricardo
2014-03-20
The Ambient Assisted Living (AAL) area is in constant evolution, providing new technologies to users and enhancing the level of security and comfort that is ensured by house platforms. The Ambient Assisted Living for All (AAL4ALL) project aims to develop a new AAL concept, supported on a unified ecosystem and certification process that enables a heterogeneous environment. The concepts of Intelligent Environments, Ambient Intelligence, and the foundations of the Ambient Assisted Living are all presented in the framework of this project. In this work, we consider a specific platform developed in the scope of AAL4ALL, called UserAccess. The architecture of the platform and its role within the overall AAL4ALL concept, the implementation of the platform, and the available interfaces are presented. In addition, its feasibility is validated through a series of tests.
A Caregiver Support Platform within the Scope of an Ambient Assisted Living Ecosystem
Costa, Angelo; Novais, Paulo; Simoes, Ricardo
2014-01-01
The Ambient Assisted Living (AAL) area is in constant evolution, providing new technologies to users and enhancing the level of security and comfort that is ensured by house platforms. The Ambient Assisted Living for All (AAL4ALL) project aims to develop a new AAL concept, supported on a unified ecosystem and certification process that enables a heterogeneous environment. The concepts of Intelligent Environments, Ambient Intelligence, and the foundations of the Ambient Assisted Living are all presented in the framework of this project. In this work, we consider a specific platform developed in the scope of AAL4ALL, called UserAccess. The architecture of the platform and its role within the overall AAL4ALL concept, the implementation of the platform, and the available interfaces are presented. In addition, its feasibility is validated through a series of tests. PMID:24658626
Code of Federal Regulations, 2010 CFR
2010-04-01
... FHIP: (a) Testers must not have prior felony convictions or convictions of crimes involving fraud or... not: (1) Have an economic interest in the outcome of the test, without prejudice to the right of any...
Code of Federal Regulations, 2012 CFR
2012-04-01
... FHIP: (a) Testers must not have prior felony convictions or convictions of crimes involving fraud or... not: (1) Have an economic interest in the outcome of the test, without prejudice to the right of any...
Code of Federal Regulations, 2014 CFR
2014-04-01
... FHIP: (a) Testers must not have prior felony convictions or convictions of crimes involving fraud or... not: (1) Have an economic interest in the outcome of the test, without prejudice to the right of any...
Code of Federal Regulations, 2013 CFR
2013-04-01
... FHIP: (a) Testers must not have prior felony convictions or convictions of crimes involving fraud or... not: (1) Have an economic interest in the outcome of the test, without prejudice to the right of any...
Code of Federal Regulations, 2011 CFR
2011-04-01
... FHIP: (a) Testers must not have prior felony convictions or convictions of crimes involving fraud or... not: (1) Have an economic interest in the outcome of the test, without prejudice to the right of any...
SPHERES ultrasound beacon tester floats in Node 1 during Expedition 8
2004-03-24
ISS008-E-19132 (24 March 2004) --- The Synchronized Position Hold, Engage, Reorient, Experimental Satellites (SPHERES) Beacon / Beacon Tester floats in the Unity node of the International Space Station.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hallerman, G.; Gray, R.J.
The design and testing procedures of two elevatedtemperature hardness testers are described. One device uses a Rockwell tester with a large vertical capacity and a load range of 15 to 150 kg. The tester is equipped with a 900 deg C heating chamber which maintains an argon atmosphere over the specimen and can be laterally displaced by a cross-feed mechanism to allow repeated hardness readings to be made on the same specimen. The second instrument is a microindentation hardness tester for hardness determinations to a maximum temperature of 1000 deg C in vacuum of 10/sup -4/ to 10/sup -5/ torr.more » A deadweight loading system with a 136-deg diamond pyramid (Vickers) indenter, capable of delivering static loads between 0.150 and 3 kg, is contained within the vacuum chamber to avoid calibration problems that arise when loads are applied from outside the vacuum system. The microindentation hardness tester allows up to 100 determinations to be made on a single specimen without opening the test chamber. The applicability of the testers is illustrated by elevatedtemperature hardness measurements on several commercial alloys, a group of niobium-vanadium alloys, and by the changes in hardness occurring at the transformation temperatures of iron and steel. Hardness values of Haynes alloy No. 25 were determined at the temperatures of aging and are shown to be different from those obtained with the customary method of investigating age hardening. The testing is currently being used to aid and accelerate the development of alloys with desirable high-temperature properties. (auth)« less
A comparison of damage profiling of automated tap testers on aircraft CFRP panel
NASA Astrophysics Data System (ADS)
Mohd Aris, K. D.; Shariff, M. F.; Abd Latif, B. R.; Mohd Haris, M. Y.; Baidzawi, I. J.
2017-12-01
The use of composite materials nevertheless is getting more prominent. The combination of reinforcing fibers and matrices will produce the desired strength orientation, tailorability and not to mention the complex shape that is hard to form on metallic structure. The weight percentage of composite materials used in aerospace, civil, marine etc. has increased tremendously. Since composite are stacked together, the possibility of delamination and/disbond defects are highly present either in the monolithic or sandwich structures. Tap test is the cheapest form of nondestructive test to identify the presence of this damage. However, its inconsistency and wide area of coverage can reduce its effectivity since it is carried out manually. The indigenous automated tap tester known as KETOK was used to detect the damage due to trapped voids and air pockets. The mechanism of detection is through controlling the tapping on the surface automatically at a constant rate. Another manual tap tester RD-3 from Wichitech Industries Inc. was used as reference. The acquired data was translated into damage profiling and both results were compared. The results have shown that the indigenous automated tester can profile the damage better when compared with the existing tap tester. As a conclusion, the indigenous automated tap tester has a potential to be used as an IN-SITU damage detection tool to detect delamination and disbond damage on composite panel. However, more conclusive tests need to be done in order to make the unit available to conventional users.
Space assembly fixtures and aids
NASA Technical Reports Server (NTRS)
Bloom, K. A.; Lillenas, A. N.
1980-01-01
Concepts and requirements for assembly fixtures and aids necessary for the assembly and maintenance of spare platforms were studied. Emphasis was placed on erectable and deployable type structures with the shuttle orbiter as the assembly base. Both single and multiple orbiter flight cases for the platform assembly were considered. Applicable space platform assembly studies were reviewed to provide a data base for establishing the assembly fixture and aids design requirements, assembly constraints, and the development of representative design concepts. Conclusions indicated that fixture requirements will vary with platform size. Larger platforms will require translation relative to the orbiter RMS working volume. The installation of platform payloads and subsystems (e.g., utility distribution) must also be considered in the specification of assembly fixtures and aids.
Limited electromagnetic interference testing of evidential breath testers
DOT National Transportation Integrated Search
1983-05-06
This report summarizes a limited test program conducted to determine the susceptibility of evidential breath testers (EBTs) to radio frequency interference (RFI). Several comprehensive test protocols were prepared based on procedures developed by the...
Transducer Workshop (17th) Held in San Diego, California on June 22-24, 1993
1993-06-01
weight in a drop tower, such as the primer tester shown in figure 1. The calibration procedure must be repeated for each lot of copper inserts, and small...force vs. time curve (i.e impulse = area unxer the curve). The FPyF can be used in the primer tester (shown in figure 1) as well as in a weapon...microphones. Plstonphone Output 124 dB, 250 Hz DEAD WEIGHT TESTIER USED AS A PRESSURE RELEASE CALIBRATOR The dead weight tester is designed and most
Obermeyer, Carla Makhlouf; Neuman, Melissa; Desclaux, Alice; Wanyenze, Rhoda; Ky-Zerbo, Odette; Cherutich, Peter; Namakhoma, Ireen; Hardon, Anita
2012-01-01
Background Recommendations about scaling up HIV testing and counseling highlight the need to provide key services and to protect clients' rights, but it is unclear to what extent different modes of testing differ in this respect. This paper examines whether practices regarding consent, confidentiality, and referral vary depending on whether testing is provided through voluntary counseling and testing (VCT) or provider-initiated testing. Methods and Findings The MATCH (Multi-Country African Testing and Counseling for HIV) study was carried out in Burkina Faso, Kenya, Malawi, and Uganda. Surveys were conducted at selected facilities. We defined eight outcome measures related to pre- and post-test counseling, consent, confidentiality, satisfactory interactions with providers, and (for HIV-positive respondents) referral for care. These were compared across three types of facilities: integrated facilities, where testing is provided along with medical care; stand-alone VCT facilities; and prevention of mother-to-child transmission (PMTCT) facilities, where testing is part of PMTCT services. Tests of bivariate associations and modified Poisson regression were used to assess significance and estimate the unadjusted and adjusted associations between modes of testing and outcome measures. In total, 2,116 respondents tested in 2007 or later reported on their testing experience. High percentages of clients across countries and modes of testing reported receiving recommended services and being satisfied. In the unadjusted analyses, integrated testers were less likely to meet with a counselor before testing (83% compared with 95% of VCT testers; p<0.001), but those who had a pre-test meeting were more likely to have completed consent procedures (89% compared with 83% among VCT testers; p<0.001) and pre-test counseling (78% compared with 73% among VCT testers; p = 0.015). Both integrated and PMTCT testers were more likely to receive complete post-test counseling than were VCT testers (59% among both PMTCT and integrated testers compared with 36% among VCT testers; p<0.001). Adjusted analyses by country show few significant differences by mode of testing: only lower satisfaction among integrated testers in Burkina Faso and Uganda, and lower frequency of referral among PMTCT testers in Malawi. Adjusted analyses of pooled data across countries show a higher likelihood of pre-test meeting for those testing at VCT facilities (adjusted prevalence ratio: 1.22, 95% CI: 1.07–1.38) and higher satisfaction for stand-alone VCT facilities (adjusted prevalence ratio: 1.15; 95% CI: 1.06–1.25), compared to integrated testing, but no other associations were statistically significant. Conclusions Overall, in this study most respondents reported favorable outcomes for consent, confidentiality, and referral. Provider-initiated ways of delivering testing and counseling do not appear to be associated with less favorable outcomes for clients than traditional, client-initiated VCT, suggesting that testing can be scaled up through multiple modes without detriment to clients' rights. Please see later in the article for the Editors' Summary PMID:23109914
Obermeyer, Carla Makhlouf; Neuman, Melissa; Desclaux, Alice; Wanyenze, Rhoda; Ky-Zerbo, Odette; Cherutich, Peter; Namakhoma, Ireen; Hardon, Anita
2012-01-01
Recommendations about scaling up HIV testing and counseling highlight the need to provide key services and to protect clients' rights, but it is unclear to what extent different modes of testing differ in this respect. This paper examines whether practices regarding consent, confidentiality, and referral vary depending on whether testing is provided through voluntary counseling and testing (VCT) or provider-initiated testing. The MATCH (Multi-Country African Testing and Counseling for HIV) study was carried out in Burkina Faso, Kenya, Malawi, and Uganda. Surveys were conducted at selected facilities. We defined eight outcome measures related to pre- and post-test counseling, consent, confidentiality, satisfactory interactions with providers, and (for HIV-positive respondents) referral for care. These were compared across three types of facilities: integrated facilities, where testing is provided along with medical care; stand-alone VCT facilities; and prevention of mother-to-child transmission (PMTCT) facilities, where testing is part of PMTCT services. Tests of bivariate associations and modified Poisson regression were used to assess significance and estimate the unadjusted and adjusted associations between modes of testing and outcome measures. In total, 2,116 respondents tested in 2007 or later reported on their testing experience. High percentages of clients across countries and modes of testing reported receiving recommended services and being satisfied. In the unadjusted analyses, integrated testers were less likely to meet with a counselor before testing (83% compared with 95% of VCT testers; p<0.001), but those who had a pre-test meeting were more likely to have completed consent procedures (89% compared with 83% among VCT testers; p<0.001) and pre-test counseling (78% compared with 73% among VCT testers; p = 0.015). Both integrated and PMTCT testers were more likely to receive complete post-test counseling than were VCT testers (59% among both PMTCT and integrated testers compared with 36% among VCT testers; p<0.001). Adjusted analyses by country show few significant differences by mode of testing: only lower satisfaction among integrated testers in Burkina Faso and Uganda, and lower frequency of referral among PMTCT testers in Malawi. Adjusted analyses of pooled data across countries show a higher likelihood of pre-test meeting for those testing at VCT facilities (adjusted prevalence ratio: 1.22, 95% CI: 1.07-1.38) and higher satisfaction for stand-alone VCT facilities (adjusted prevalence ratio: 1.15; 95% CI: 1.06-1.25), compared to integrated testing, but no other associations were statistically significant. Overall, in this study most respondents reported favorable outcomes for consent, confidentiality, and referral. Provider-initiated ways of delivering testing and counseling do not appear to be associated with less favorable outcomes for clients than traditional, client-initiated VCT, suggesting that testing can be scaled up through multiple modes without detriment to clients' rights. Please see later in the article for the Editors' Summary.
NASA Technical Reports Server (NTRS)
1982-01-01
The programmatic data for the reference concept of the Manned Space Platform is presented. Details regarding work breakdown structure (WBS) and dictionary, the facilities and equipment required to produce the modules, the project schedule and logic diagram, a preliminary assessment of environmental impacts and details regarding the estimated costs for the reference concept are included. The proposed WBS which was developed to provide summary and system level segregation of the nonrecurring and recurring portions of the Manned Space Platform project is also included. The accompanying dictionary outlines the function and activities contained within each WBS element. The facility and equipment required to produce the various modules is discussed. Generally, required equipment is within the existing state of the art although the size of some of the items to be manufactured is a consideration. A preliminary manufacturing flow was also provided. The project schedules presented consist of the Master Project Summary Schedule, the Master Project Phasing Chart and the Logic Network.
Darius, H T; Drescher, O; Ponton, D; Pawlowiez, R; Laurent, D; Dewailly, E; Chinain, M
2013-01-01
Ciguatera fish poisoning is a seafood intoxication commonly afflicting island communities in the Pacific. These populations, which are strongly dependent on fish resources, have developed over centuries various strategies to decrease the risk of intoxication, including the use of folk tests to detect ciguateric fish. This study aims to evaluate the effectiveness of two folk tests commonly used in Raivavae Island (Australes, French Polynesia): the rigor mortis test (RMT) and the bleeding test (BT). A total of 107 fish were collected in Raivavae Lagoon, among which 80 were tested by five testers using the RMT versus 107 tested by four testers using BT. First, the performance between testers was compared. Second, the efficiency of these tests was compared with toxicity data obtained via the receptor binding assay (RBA) by assessing various parameter's values such as sensitivity (Se), specificity (Sp), positive predictive value (PPV) and negative predictive value (NPV). Comparisons of outcomes between folk tests and RBA analyses were considered: tests used separately or in a parallel versus the series approach by each tester. The overall efficiency of the RMT and BT tests was also evaluated when the judgments of all testers were "pooled". The results demonstrate that efficiencies varied between testers with one showing the best scores in detecting toxic fish: 55% with RMT and 69.2% with BT. BT gave the best results in detecting toxic fish as compared with RMT, giving also better agreement between testers. If high NPV and Se values were to be privileged, the data also suggest that the best way to limit cases of intoxication would be to use RMT and BT tests in a parallel approach. The use of traditional knowledge and a good knowledge of risky versus healthy fishing areas may help reduce the risk of intoxication among communities where ciguatera fish poisoning is highly prevalent.
de Vreede, Paul L; Samson, Monique M; van Meeteren, Nico L; Duursma, Sijmen A; Verhaar, Harald J
2006-08-01
The Assessment of Daily Activity Performance (ADAP) test was developed, and modeled after the Continuous-scale Physical Functional Performance (CS-PFP) test, to provide a quantitative assessment of older adults' physical functional performance. The aim of this study was to determine the intra-examiner reliability and construct validity of the ADAP in a community-living older population, and to identify the importance of tester experience. Forty-three community-dwelling, older women (mean age 75 yr +/-4.3) were randomized to the test-retest reliability study (n=19) or validation study (n=24). The intra-examiner reliability of an experienced (tester 1) and an inexperienced tester (tester 2) was assessed by comparing test and retest scores of 19 participants. Construct validity was assessed by comparing the ADAP scores of 24 participants with self-perceived function by the SF-36 Health Survey, muscle function tests, and the Timed Up and Go test (TUG). Tester 1 had good consistency and reliability scores (mean difference between test and retest scores (DIF), -1.05+/-1.99; 95% confidence interval (CI), -2.58 to 0.48; Cronbach's alpha (alpha) range, 0.83 to 0.98; intraclass correlation (ICC) range, 0.75 to 0.96; Limits of Agreement (LoA), -2.58 to 4.95). Tester 2 had lower reliability scores (DIF, -2.45+/-4.36; 95% CI, -5.56 to 0.67; alpha range, 0.53 to 0.94; ICC range, 0.36 to 0.90; LoA, -6.09 to 10.99), with a systematic difference between test and retest scores for the ADAP domain lower-body strength (-3.81; 95% CI, -6.09 to -1.54), ADAP correlated with SF-36 Physical Functioning scale (r=0.67), TUG test (r=-0.91) and with isometric knee extensor strength (r=0.80). The ADAP test is a reliable and valid instrument. Our results suggest that testers should practise using the test, to improve reliability, before applying it to clinical settings.
George, Christine Marie; van Geen, Alexander; Slavkovich, Vesna; Singha, Ashit; Levy, Diane; Islam, Tariqul; Ahmed, Kazi Matin; Moon-Howard, Joyce; Tarozzi, Alessandro; Liu, Xinhua; Factor-Litvak, Pam; Graziano, Joseph
2012-06-19
To reduce arsenic (As) exposure, we evaluated the effectiveness of training community members to perform water arsenic (WAs) testing and provide As education compared to sending representatives from outside communities to conduct these tasks. We conducted a cluster based randomized controlled trial of 20 villages in Singair, Bangladesh. Fifty eligible respondents were randomly selected in each village. In 10 villages, a community member provided As education and WAs testing. In a second set of 10 villages an outside representative performed these tasks. Overall, 53% of respondents using As contaminated wells, relative to the Bangladesh As standard of 50 μg/L, at baseline switched after receiving the intervention. Further, when there was less than 60% arsenic contaminated wells in a village, the classification used by the Bangladeshi and UNICEF, 74% of study households in the community tester villages, and 72% of households in the outside tester villages reported switching to an As safe drinking water source. Switching was more common in the outside-tester (63%) versus community-tester villages (44%). However, after adjusting for the availability of arsenic safe drinking water sources, well switching did not differ significantly by type of As tester (Odds ratio = 0.86[95% confidence interval 0.42-1.77). At follow-up, among those using As contaminated wells who switched to safe wells, average urinary As concentrations significantly decreased. The overall intervention was effective in reducing As exposure provided there were As-safe drinking water sources available. However, there was not a significant difference observed in the ability of the community and outside testers to encourage study households to use As-safe water sources. The findings of this study suggest that As education and WAs testing programs provided by As testers, irrespective of their residence, could be used as an effective, low cost approach to reduce As exposure in many As-affected areas of Bangladesh.
The Participation Scale: measuring a key concept in public health.
van Brakel, Wim H; Anderson, Alison M; Mutatkar, R K; Bakirtzief, Zoica; Nicholls, Peter G; Raju, M S; Das-Pattanayak, Robert K
2006-02-28
To develop a scale to measure (social) participation for use in rehabilitation, stigma reduction and social integration programmes. A scale development study was carried out in Nepal, India and Brazil using standard methods. The instrument was to be based on the Participation domains of the International Classification of Functioning, Disability and Health (ICF), be cross-cultural in nature and assess client-perceived participation. Respondents rated their participation in comparison with a "peer", defined as "someone similar to the respondent in all respects except for the disease or disability". An 18-item instrument was developed in seven languages. Crohnbach's alpha was 0.92, intra-tester stability 0.83 and inter-tester reliability 0.80. Discrimination between controls and clients was good at a Participation Score threshold of 12. Responsiveness after a "life change" was according to expectation. The Participation Scale is reliable and valid to measure client-perceived participation in people affected by leprosy or disability. It is expected to be valid in other (stigmatised) conditions also, but this needs confirmation. The scale allows collection of participation data and impact assessment of interventions to improve social participation. Such data may be compared between clients, interventions and programmes. The scale is suitable for use in institutions, but also at the peripheral level.
(Quickly) Testing the Tester via Path Coverage
NASA Technical Reports Server (NTRS)
Groce, Alex
2009-01-01
The configuration complexity and code size of an automated testing framework may grow to a point that the tester itself becomes a significant software artifact, prone to poor configuration and implementation errors. Unfortunately, testing the tester by using old versions of the software under test (SUT) may be impractical or impossible: test framework changes may have been motivated by interface changes in the tested system, or fault detection may become too expensive in terms of computing time to justify running until errors are detected on older versions of the software. We propose the use of path coverage measures as a "quick and dirty" method for detecting many faults in complex test frameworks. We also note the possibility of using techniques developed to diversify state-space searches in model checking to diversify test focus, and an associated classification of tester changes into focus-changing and non-focus-changing modifications.
System architecture of a gallium arsenide one-gigahertz digital IC tester
NASA Technical Reports Server (NTRS)
Fouts, Douglas J.; Johnson, John M.; Butner, Steven E.; Long, Stephen I.
1987-01-01
The design for a 1-GHz digital integrated circuit tester for the evaluation of custom GaAs chips and subsystems is discussed. Technology-related problems affecting the design of a GaAs computer are discussed, with emphasis on the problems introduced by long printed-circuit-board interconnect. High-speed interface modules provide a link between the low-speed microprocessor and the chip under test. Memory-multiplexer and memory-shift register architectures for the storage of test vectors are described in addition to an architecture for local data storage consisting of a long chain of GaAs shift registers. The tester is constructed around a VME system card cage and backplane, and very little high-speed interconnect exists between boards. The tester has a three part self-test consisting of a CPU board confidence test, a main memory confidence test, and a high-speed interface module functional test.
Evaluation of a laser road surface tester.
DOT National Transportation Integrated Search
1995-01-01
The purpose of this study was to evaluate the accuracy and usefulness of pavement distress data derived from a laser road surface tester (RST) operating on Virginia's interstate highway system. The evaluation was conducted by comparing rut depth, rou...
DOT National Transportation Integrated Search
2010-01-01
This research evaluated the stiffness and permanent deformation properties of typical Wisconsin Department of : Transportation (WisDOT) asphalt mixtures using the Asphalt Mixture Performance Tester (AMPT) and associated test and : analysis procedures...
40 CFR 261.21 - Characteristic of ignitability.
Code of Federal Regulations, 2011 CFR
2011-07-01
... determined by a Pensky-Martens Closed Cup Tester, using the test method specified in ASTM Standard D 93-79 or D 93-80 (incorporated by reference, see § 260.11), or a Setaflash Closed Cup Tester, using the test...
40 CFR 261.21 - Characteristic of ignitability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... determined by a Pensky-Martens Closed Cup Tester, using the test method specified in ASTM Standard D 93-79 or D 93-80 (incorporated by reference, see § 260.11), or a Setaflash Closed Cup Tester, using the test...
Scheftic, Charlie M.; Brinson, L. Catherine
2018-01-01
The cost of specialized scientific equipment can be high and with limited funding resources, researchers and students are often unable to access or purchase the ideal equipment for their projects. In the fields of materials science and mechanical engineering, fundamental equipment such as tensile testing devices can cost tens to hundreds of thousands of dollars. While a research lab often has access to a large-scale testing machine suitable for conventional samples, loading devices for meso- and micro-scale samples for in-situ testing with the myriad of microscopy tools are often hard to source and cost prohibitive. Open-source software has allowed for great strides in the reduction of costs associated with software development and open-source hardware and additive manufacturing have the potential to similarly reduce the costs of scientific equipment and increase the accessibility of scientific research. To investigate the feasibility of open-source hardware, a micro-tensile tester was designed with a freely accessible computer-aided design package and manufactured with a desktop 3D-printer and off-the-shelf components. To our knowledge this is one of the first demonstrations of a tensile tester with additively manufactured components for scientific research. The capabilities of the tensile tester were demonstrated by investigating the mechanical properties of Graphene Oxide (GO) paper and thin films. A 3D printed tensile tester was successfully used in conjunction with an atomic force microscope to provide one of the first quantitative measurements of GO thin film buckling under compression. The tensile tester was also used in conjunction with an atomic force microscope to observe the change in surface topology of a GO paper in response to increasing tensile strain. No significant change in surface topology was observed in contrast to prior hypotheses from the literature. Based on this result obtained with the new open source tensile stage we propose an alternative hypothesis we term ‘superlamellae consolidation’ to explain the initial deformation of GO paper. The additively manufactured tensile tester tested represents cost savings of >99% compared to commercial solutions in its class and offers simple customization. However, continued development is needed for the tensile tester presented here to approach the technical specifications achievable with commercial solutions. PMID:29813103
Nandy, Krishanu; Collinson, David W; Scheftic, Charlie M; Brinson, L Catherine
2018-01-01
The cost of specialized scientific equipment can be high and with limited funding resources, researchers and students are often unable to access or purchase the ideal equipment for their projects. In the fields of materials science and mechanical engineering, fundamental equipment such as tensile testing devices can cost tens to hundreds of thousands of dollars. While a research lab often has access to a large-scale testing machine suitable for conventional samples, loading devices for meso- and micro-scale samples for in-situ testing with the myriad of microscopy tools are often hard to source and cost prohibitive. Open-source software has allowed for great strides in the reduction of costs associated with software development and open-source hardware and additive manufacturing have the potential to similarly reduce the costs of scientific equipment and increase the accessibility of scientific research. To investigate the feasibility of open-source hardware, a micro-tensile tester was designed with a freely accessible computer-aided design package and manufactured with a desktop 3D-printer and off-the-shelf components. To our knowledge this is one of the first demonstrations of a tensile tester with additively manufactured components for scientific research. The capabilities of the tensile tester were demonstrated by investigating the mechanical properties of Graphene Oxide (GO) paper and thin films. A 3D printed tensile tester was successfully used in conjunction with an atomic force microscope to provide one of the first quantitative measurements of GO thin film buckling under compression. The tensile tester was also used in conjunction with an atomic force microscope to observe the change in surface topology of a GO paper in response to increasing tensile strain. No significant change in surface topology was observed in contrast to prior hypotheses from the literature. Based on this result obtained with the new open source tensile stage we propose an alternative hypothesis we term 'superlamellae consolidation' to explain the initial deformation of GO paper. The additively manufactured tensile tester tested represents cost savings of >99% compared to commercial solutions in its class and offers simple customization. However, continued development is needed for the tensile tester presented here to approach the technical specifications achievable with commercial solutions.
NASA Technical Reports Server (NTRS)
1981-01-01
The objectives were to define, evaluate, and select concepts for evolving a space station in conjunction with the Space Platform for NASA science, Applications, Technology and DOD; and a permanently manned presence in space early, with a maximum of existing technology.
New reaction tester accurate within 56 microseconds
NASA Technical Reports Server (NTRS)
Brown, H.
1972-01-01
Testing device measures simple and disjunctive reaction time of human subject to light stimuli. Tester consists of reaction key, logic card, panel mounted neon indicators, and interconnecting wiring. Device is used for determining reaction times of patients undergoing postoperative neurological therapy.
Evaluation of IMS - Swedish Laser road tester : final report.
DOT National Transportation Integrated Search
1990-09-01
A test of the IMS - Swedish Laser road tester was conducted in September 1988. The vehicle mounted laser equipment was used to survey pavement conditions on sections of Oregon's Interstate and non-interstate highway system. : The IMS laser equipment ...
NASA Technical Reports Server (NTRS)
Oneal, Melvin R.; Task, H. Lee; Genco, Louis V.
1992-01-01
Viewgraphs on effect of microgravity on visual contrast threshold during STS shuttle missions are presented. The purpose, methods, and results are discussed. The visual function tester model 2 is used.
Exploring the Use of a Test Automation Framework
NASA Technical Reports Server (NTRS)
Cervantes, Alex
2009-01-01
It is known that software testers, more often than not, lack the time needed to fully test the delivered software product within the time period allotted to them. When problems in the implementation phase of a development project occur, it normally causes the software delivery date to slide. As a result, testers either need to work longer hours, or supplementary resources need to be added to the test team in order to meet aggressive test deadlines. One solution to this problem is to provide testers with a test automation framework to facilitate the development of automated test solutions.
Ibrahim, Sarah A; Martini, Luigi
2014-08-01
Dissolution method transfer is a complicated yet common process in the pharmaceutical industry. With increased pharmaceutical product manufacturing and dissolution acceptance requirements, dissolution testing has become one of the most labor-intensive quality control testing methods. There is an increased trend for automation in dissolution testing, particularly for large pharmaceutical companies to reduce variability and increase personnel efficiency. There is no official guideline for dissolution testing method transfer from a manual, semi-automated, to automated dissolution tester. In this study, a manual multipoint dissolution testing procedure for an enteric-coated aspirin tablet was transferred effectively and reproducibly to a fully automated dissolution testing device, RoboDis II. Enteric-coated aspirin samples were used as a model formulation to assess the feasibility and accuracy of media pH change during continuous automated dissolution testing. Several RoboDis II parameters were evaluated to ensure the integrity and equivalency of dissolution method transfer from a manual dissolution tester. This current study provides a systematic outline for the transfer of the manual dissolution testing protocol to an automated dissolution tester. This study further supports that automated dissolution testers compliant with regulatory requirements and similar to manual dissolution testers facilitate method transfer. © 2014 Society for Laboratory Automation and Screening.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poljak, M.D.
1985-08-12
This abstract discloses an improved battery tester for determining the acceptability of a Lithium Sulfur Dioxide (LiSO/sub 2/) storage battery at a given temperature and with one or more cells therein. The tester is generally made up of a first-comparison circuit having a series of series-interconnected components, namely a comparator, first and second flip-flops, and an AND gate. A first resistor is parallel connected to the first-comparison circuit. A second comparison circuit is also parallel connected to the first-comparison circuit and is generally made up of series-interconnected components, namely a second resistor, a capacitor, a buffer, and a second-comparator. Amore » first switch is connected to the first resistor and a second switch is parallel connected to the second-comparison circuit between the capacitor and the buffer. A logic control arrangement controls the operation of both switches, both comparators, and both flip-flops for testing a battery as to its start-up voltage and performance voltage characteristics all in a relatively short time period. In another embodiment of the tester, it is provided with an analog-to-digital converter, a memory, and a sensor arrangement for enhancing the versatility and reliability of the tester in determining the acceptability of a LiSO/sub 2/ battery.« less
Male recombination in Brazilian populations of Drosophila ananassae.
Goñi, Beatriz; Matsuda, Muneo; Tobari, Yoshiko N
2016-07-01
With few exceptions, spontaneous crossing over does not normally occur in male Drosophila. Drosophila ananassae males show considerable amounts of crossing over. In wild males of D. ananassae from Asian (2008) and Brazilian populations (1986 and 2007) variable frequencies of meiotic crossing over, estimated from chiasmata counts, suggested the existence of factors controlling male crossing over in these populations. To corroborate for such prediction, we present data on spontaneous recombination in F1 males of D. ananassae heterozygous for chromosomes of the same Brazilian populations (1986) and marker chromosomes using three testers stocks. Mean recombination value was low, although high variability existed between individual frequencies. Recombination frequencies between lines in each tester stock were not significantly different, excepting when the 3ple-px and 3ple-cy testers were compared (p < 0.05). These two testers differ in respect to the regional distribution of crossovers. The occurrence of recombination in chromosomes 2 and 3 in F1 males tested with e(65) se; bri ru was not related, suggesting they are under independent genetic control. Our data are consistent with proposed genetic factors controlling male crossing over in the tester stocks and to the presence of enhancers and suppressors of male crossing over segregating in the Brazilian populations (1986).
Results of the first semi-annual qualification testing of devices to measure breath alcohol
DOT National Transportation Integrated Search
1975-01-01
Eight evidential breath testers were performance tested according to the Standard for Devices to Measure Breath Alcohol Federal Register, Vol 38, No. 212, November 5, 1973. In addition, a prototype breath tester not commercially available was tested....
The accuracy of evidential breath testers at low BACs
DOT National Transportation Integrated Search
1989-05-01
This Technical Note reports on the low blood alcohol concentration (BAC) laboratory testing of seven evidential breath testers widely used by law enforcement. The findings indicated that these devices are just as accurate at low BACs in the 0.020-0.0...
NASA Technical Reports Server (NTRS)
Stoms, R. M.
1984-01-01
Numerically-controlled 5-axis machine tool uses transformer and meter to determine and indicate whether tool is in home position, but lacks built-in test mode to check them. Tester makes possible test, and repair of components at machine rather then replace them when operation seems suspect.
NASA Technical Reports Server (NTRS)
Oneal, Melvin R.; Task, H. Lee; Genco, Louis V.
1992-01-01
Viewgraphs on the effect of microgravity on several visual functions during STS shuttle missions are presented. The purpose, methods, results, and discussion are discussed. The visual function tester model 1 is used.
Communications platform payload definition study, executive summary
NASA Technical Reports Server (NTRS)
Clopp, H. W.; Hawkes, T. A.; Bertles, C. R.; Pontano, B. A.; Kao, T.
1986-01-01
Large geostationary communications platforms have been investigated in a number of studies since 1974 as a possible means to more effectively utilize the geostationary orbital arc and electromagnetic spectrum and to reduce overall satellite communications system costs. This NASA Lewis sponsored study addresses the commercial feasibility of various communications platform payload concepts circa 1998. It defines promising payload concepts, estimates recurring costs and identifies critical technologies needed to permit eventual commercialization. Ten communications service aggregation scenarios describing potential groupings of services were developed for a range of conditions. Payload concepts were defined for four of these scenarios: (1) Land Mobile Satellite Service (LMSS), meet 100% of CONUS plus Canada demand with a single platform; (2) Fixed Satellite Service (FSS) (Trunking + Customer Premises Service (CPS), meet 20% of CONUS demands; (3) FSS (Trunking + video distribution), 10 to 13% of CONUS demand; and (4) FSS (20% of demand) + Inter Satellite Links (ISL) + TDRSS/TDAS Data Distribution.
SCHUMACHER, RICHARD M.; ARABAS, JANA L.; MAYHEW, JERRY L.; BRECHUE, WILLIAM F.
2016-01-01
The purpose of this study was to determine the effect of inter-investigator differences in anthropometric assessments on the prediction of one-repetition maximum (1RM) bench press in college football players. Division-II players (n = 34, age = 20.4 ± 1.2 y, 182.3 ± 6.6 cm, 99.1 ± 18.4 kg) were measured for selected anthropometric variables and 1RM bench press at the conclusion of a heavy resistance training program. Triceps, subscapular, and abdominal skinfolds were measured in triplicate by three investigators and used to estimate %fat. Arm circumference was measured around a flexed biceps muscle and was corrected for triceps skinfold to estimate muscle cross-sectional area (CSA). Chest circumference was measured at mid-expiration. Significant differences among the testers were evident in six of the nine anthropometric variables, with the least experienced tester being significantly different from the other testers on seven variables, although average differences among investigators ranged from 1–2% for circumferences to 4–9% for skinfolds. The two more experienced testers were significantly different on only one variable. Overall agreement among testers was high (ICC>0.895) for each variable, with low coefficients of variation (CV<10.7%). Predicted 1RMs for testers (126.9 ± 20.6, 123.4 ± 22.0, and 132.1 ± 28.4 kg, respectively) were not significantly different from actual 1RM (129.2 ± 20.6 kg). Individuals with varying levels of experience appear to have an acceptable level of ability to estimate 1RM bench press using a non-performance anthropometric equation. Minimal experience in anthropometry may not impede strength and conditioning specialists from accurately estimating 1RM bench press. PMID:27766130
Schumacher, Richard M; Arabas, Jana L; Mayhew, Jerry L; Brechue, William F
2016-01-01
The purpose of this study was to determine the effect of inter-investigator differences in anthropometric assessments on the prediction of one-repetition maximum (1RM) bench press in college football players. Division-II players (n = 34, age = 20.4 ± 1.2 y, 182.3 ± 6.6 cm, 99.1 ± 18.4 kg) were measured for selected anthropometric variables and 1RM bench press at the conclusion of a heavy resistance training program. Triceps, subscapular, and abdominal skinfolds were measured in triplicate by three investigators and used to estimate %fat. Arm circumference was measured around a flexed biceps muscle and was corrected for triceps skinfold to estimate muscle cross-sectional area (CSA). Chest circumference was measured at mid-expiration. Significant differences among the testers were evident in six of the nine anthropometric variables, with the least experienced tester being significantly different from the other testers on seven variables, although average differences among investigators ranged from 1-2% for circumferences to 4-9% for skinfolds. The two more experienced testers were significantly different on only one variable. Overall agreement among testers was high (ICC>0.895) for each variable, with low coefficients of variation (CV<10.7%). Predicted 1RMs for testers (126.9 ± 20.6, 123.4 ± 22.0, and 132.1 ± 28.4 kg, respectively) were not significantly different from actual 1RM (129.2 ± 20.6 kg). Individuals with varying levels of experience appear to have an acceptable level of ability to estimate 1RM bench press using a non-performance anthropometric equation. Minimal experience in anthropometry may not impede strength and conditioning specialists from accurately estimating 1RM bench press.
Thorborg, Kristian; Bandholm, Thomas; Hölmich, Per
2013-03-01
In football, ice-hockey, and track and field, injuries have been predicted, and hip- and knee-strength deficits quantified using hand-held dynamometry (HHD). However, systematic bias exists when testers of different sex and strength perform the measurements. Belt-fixation of the dynamometer may resolve this. The aim of the present study was therefore to examine the inter-tester reliability concerning strength assessments of isometric hip abduction, adduction, flexion, extension and knee-flexion strength, using HHD with external belt-fixation. Twenty-one healthy athletes (6 women), 30 (8.6) (mean (SD)) years of age, were included. Two physiotherapy students (1 female and 1 male) performed all the measurements after careful instruction and procedure training. Isometric hip abduction, adduction, flexion, extension, and knee-flexion strength were tested. The tester-order and hip-action order were randomised. No systematic between-tester differences (bias) were observed for any of the hip or knee actions. The intra-class correlation coefficients (ICC 2.1) ranged from 0.76 to 0.95. Furthermore, standard errors of measurement in per cent (SEM %) ranged from 5 to 11 %, and minimal detectable change in per cent (MDC %) from 14 to 29 % for the different hip and knee actions. The present study shows that isometric hip- and knee-strength measurements have acceptable inter-tester reliability at the group level, when testing strong individuals, using HHD with belt-fixation. This procedure is therefore perfectly suited for the evaluation and monitoring of strong athletes with hip, groin and hamstring injuries, some of the most common and troublesome injuries in sports. Diagnostic, Level III.
Watson, C J; Propps, M; Galt, W; Redding, A; Dobbs, D
1999-07-01
Test-retest reliability study with blinded testers. To determine the intratester reliability of the McConnell classification system and to determine whether the intertester reliability of this system would be improved by one-on-one training of the testers, increasing the variability and numbers of subjects, blinding the testers to the absence or presence of patellofemoral pain syndrome, and adhering to the McConnell classification system as it is taught in the "McConnell Patellofemoral Treatment Plan" continuing education course. The McConnell classification system is currently used by physical therapy clinicians to quantify static patellar orientation. The measurements generated from this system purportedly guide the therapist in the application of patellofemoral tape and in assessment of the efficacy of treatment interventions on changing patellar orientation. Fifty-six subjects (age range, 21-65 years) provided a total of 101 knees for assessment. Seventy-six knees did not produce symptoms. A researcher who did not participate in the measuring process determined that 17 subjects had patellofemoral pain syndrome in 25 knees. Two testers concurrently measured static patellar orientation (anterior/posterior and medial/lateral tilt, medial/lateral glide, and patellar rotation) on subjects, using the McConnell classification system. Repeat measures were performed 3-7 days later. A kappa (kappa) statistic was used to assess the degree of agreement within each tester and between testers. The kappa coefficients for intratester reliability varied from -0.06 to 0.35. Intertester reliability ranged from -0.03 to 0.19. The McConnell classification system, in its current form, does not appear to be very reliable. Intratester reliability ranged from poor to fair, and intertester reliability was poor to slight. This system should not be used as a measurement tool or as a basis for treatment decisions.
Knowledge Management: A Conceptual Platform for the Sharing of Ideas.
ERIC Educational Resources Information Center
Mahdjoubi, Darius; Harmon, Glynn
2001-01-01
The concept of the learning organization and intellectual capital were instrumental in the beginning stage of knowledge management, about 1995. From the spontaneous combination of these two fields, the modern concept of knowledge management as a conceptual platform emerged. The seven main fields that are so far most intimately connected to…
21 CFR 882.1410 - Electroencephalograph electrode/lead tester.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electroencephalograph electrode/lead tester. 882.1410 Section 882.1410 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1410...
21 CFR 882.1410 - Electroencephalograph electrode/lead tester.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electroencephalograph electrode/lead tester. 882.1410 Section 882.1410 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1410...
21 CFR 870.2370 - Electrocardiograph surface electrode tester.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electrocardiograph surface electrode tester. 870.2370 Section 870.2370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2370...
7 CFR 1436.6 - Eligible storage or handling equipment.
Code of Federal Regulations, 2012 CFR
2012-01-01
... eligible facility loan commodity, such as cleaners, moisture testers, and heat detectors; (4) Electrical... moisture testers, and heat detectors; (vii) Electrical equipment, including labor and materials for..., but are not limited to, the following: An insulated cement slab floor, insulation for walls and...
7 CFR 1436.6 - Eligible storage or handling equipment.
Code of Federal Regulations, 2010 CFR
2010-01-01
... stored eligible facility loan commodity, such as cleaners, moisture testers, and heat detectors; (4... moisture testers, and heat detectors; (vii) Electrical equipment, including labor and materials for..., but are not limited to, the following: An insulated cement slab floor, insulation for walls and...
7 CFR 1436.6 - Eligible storage or handling equipment.
Code of Federal Regulations, 2014 CFR
2014-01-01
... eligible facility loan commodity, such as cleaners, moisture testers, and heat detectors; (4) Electrical... moisture testers, and heat detectors; (vii) Electrical equipment, including labor and materials for..., but are not limited to, the following: An insulated cement slab floor, insulation for walls and...
7 CFR 1436.6 - Eligible storage or handling equipment.
Code of Federal Regulations, 2011 CFR
2011-01-01
... stored eligible facility loan commodity, such as cleaners, moisture testers, and heat detectors; (4... moisture testers, and heat detectors; (vii) Electrical equipment, including labor and materials for..., but are not limited to, the following: An insulated cement slab floor, insulation for walls and...
21 CFR 870.2370 - Electrocardiograph surface electrode tester.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrocardiograph surface electrode tester. 870.2370 Section 870.2370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2370...
Haas, Jeffrey S [San Ramon, CA; Howard, Douglas E [Livermore, CA; Eckels, Joel D [Livermore, CA; Nunes, Peter J [Danville, CA
2011-01-11
An explosives tester that can be used anywhere as a screening tool by non-technical personnel to determine whether a surface contains explosives. First and second explosives detecting reagent holders and dispensers are provided. A heater is provided for receiving the first and second explosives detecting reagent holders and dispensers.
7 CFR 1436.6 - Eligible storage or handling equipment.
Code of Federal Regulations, 2013 CFR
2013-01-01
... eligible facility loan commodity, such as cleaners, moisture testers, and heat detectors; (4) Electrical... moisture testers, and heat detectors; (vii) Electrical equipment, including labor and materials for..., but are not limited to, the following: An insulated cement slab floor, insulation for walls and...
PCB tester selection for future systems. Volume 2. Final report, August 1989-June 1991
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schmitt, W.
1992-06-01
This report describes a computer program (to run on an IBM compatible PC) designed to aid in the selection of a PCB tester, given the characteristics of the PC board to be tested. The program contains a limited data base of PCB testers, and others may be added easily. This report also provides a specification for a limited family of PCB testers to fill the gap between what the U.S. Air Force is expected to need and what is expected to be available within the next four to six years. The parameters used in the computer program and the specificationmore » are based on a survey of military and commercial PCBs - both those now available and those expected to come on line within the next four to six years. The results of the survey are covered in volume 2 - available from DTIC. Automatic Test Equipment, Technology Forecast, Air Force Avionics.« less
PCB tester selection for future systems. Volume 1. Final report, August 1989-June 1991
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schmitt, W.
1992-06-01
This report describes a computer program (to run on an IBM compatible PC) designed to aid in the selection of a PCB tester, given the characteristics of the PC board to be tested. The program contains a limited data base of PCB testers, and others may be added easily. This report also provides a specification for a limited family of PCB testers to fill the gap between what the U.S. Air Force is expected to need and what is expected to be available within the next four to six years. The parameters used in the computer program and the specificationmore » are based on a survey of military and commercial PCBs - both those now available and those expected to come on line within the next four to six years. The results of the survey are covered in volume 2 - available from DTIC. Automatic Test Equipment, Technology Forecast, Air Force Avionics.« less
Mulawa, Marta; Yamanis, Thespina J; Balvanz, Peter; Kajula, Lusajo J; Maman, Suzanne
2016-09-01
Men have lower rates of HIV testing and higher rates of AIDS-related mortality compared to women in sub-Saharan Africa. To assess whether there is an opportunity to increase men's uptake of testing by correcting misperceptions about testing norms, we compare men's perceptions of their closest friend's HIV testing behaviors with the friend's actual testing self-report using a unique dataset of men sampled within their social networks (n = 59) in Dar es Salaam, Tanzania. We examine the accuracy and bias of perceptions among men who have tested for HIV (n = 391) and compare them to the perceptions among men who never tested (n = 432). We found that testers and non-testers did not differ in the accuracy of their perceptions, though non-testers were strongly biased towards assuming that their closest friends had not tested. Our results lend support to social norms approaches designed to correct the biased misperceptions of non-testers to promote men's HIV testing.
Yamanis, Thespina J.; Balvanz, Peter; Kajula, Lusajo J.; Maman, Suzanne
2016-01-01
Men have lower rates of HIV testing and higher rates of AIDS-related mortality compared to women in sub-Saharan Africa. To assess whether there is an opportunity to increase men’s uptake of testing by correcting misperceptions about testing norms, we compare men’s perceptions of their closest friend’s HIV testing behaviors with the friend’s actual testing self-report using a unique dataset of men sampled within their social networks (n = 59) in Dar es Salaam, Tanzania. We examine the accuracy and bias of perceptions among men who have tested for HIV (n = 391) and compare them to the perceptions among men who never tested (n = 432). We found that testers and non-testers did not differ in the accuracy of their perceptions, though non-testers were strongly biased towards assuming that their closest friends had not tested. Our results lend support to social norms approaches designed to correct the biased misperceptions of non-testers to promote men’s HIV testing. PMID:26880322
Mission and sensor concepts for coastal and ocean monitoring using spacecraft and aircraft
NASA Technical Reports Server (NTRS)
Darnell, W. L.
1980-01-01
A concept developed for a 1990 oceanic mission which places strong emphasis on coastal monitoring needs is described and analysed. The concept assumes that use of one active spacecraft in orbit and one on standby plus airplanes and data collection platforms which provide continuing complementary coverage and surface truth. The coastal measurement requirements and goals, the prospective oceanic and coastal sensors, the spacecraft and aircraft data platforms, and the prospective orbit designs are discussed.
Erectable/deployable concepts for large space system technology
NASA Technical Reports Server (NTRS)
Agan, W. E.
1980-01-01
Erectable/deployable space structure concepts particularly relating to the development of a science and applications space platform are presented. Design and operating features for an automatic coupler clevis joint, a side latching detent joint, and a module-to-module auto lock coupler are given. An analysis of the packaging characteristics of stacked subassembly, single fold, hybrid, and double fold concepts is given for various platform structure configurations. Payload carrier systems and assembly techniques are also discussed.
Lessons Learned from JTA Tester Safety Studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
R. L. Bierbaum
2001-05-01
EP401575, Issue C, calls out a requirement to perform safety studies for testers that are used to accept Joint Test Assembly (JTA) product at Pantex (Reference 1). The underlying motivation is to ensure that personnel hazards due to inadvertent initiation of electro-explosive devices (EEDs) during JTA testing are understood and minimized. Studies have been performed on the B61-7/11 JTA, B61-3/4/10 JTA, B83 JTA, and W76 Type 2F testers at Pantex (References 2-5). Each of these studies includes an examination of the relevant Pantex tester as well as the instrumentation and War Reserve (WR) hardware. In performing these analyses, several themesmore » have emerged that could be useful for the Phase 6.3 design efforts for the weapons, the associated instrumentation, and the JTA testers. This report summarizes the lessons learned from these studies. Note that in some cases, the recommendations provided below to enhance safety during JTA testing operations (e.g., adding isolation resistors in the monitoring lines) may result in a reliability degradation or other surety impact. Thus it is important to consider these lessons learned in the context of the overall design and to make tradeoffs in light of the integrated surety objectives. The lessons learned are listed in five different categories, summarized as: (1) Instrumentation considerations; (2) WR design considerations; (3) Tester considerations; (4) Administrative procedures during JTA assembly; and (5) Administrative procedures prior to and during JTA testing. The first three focus on minimizing the probability of inadvertent application of power to EED initiation lines due to component, connector, and assembly failures. The last two describe procedural steps that can be taken at Pantex to either minimize the risk (e.g., by ensuring that tester power supplies cannot supply excessive power to the unit under test) or to mitigate the consequences of unexpected EED initiation (e.g., by instructing test operators to avoid standing in areas where they could be at risk in the event of EED initiation).« less
A concept design of three rudders-shaped like body in columns for low-drag USV
NASA Astrophysics Data System (ADS)
Azzeri, M. N.; Adnan, F. A.; Adi, M.; Zain, M. Z. Md
2016-06-01
This paper presented a new design for the unmanned surface vessel (USV) platform with a self-manoeuvring system which is capable of collecting the same data as a hydrography boat. This platform was designed with three hulls that were placed in triangle position. The hulls designed were in the form of rudders-shape and were vertically placed as a slender body shape using NACA 64-0012 profile. This provides the USV with low-drag characteristic. The application of stability and resistance theories investigated the effect of the configuration position of the three hulls for this platform. The results revealed that a larger configuration distance between the three hulls will lead to a reduction in resistance and the platform will be in highly stable condition. The relationships derived from these findings should produce a stable and low-drag platform to accomplish the design concept of three rudders-shaped like body in columns for low-drag USV. This concept may help us to accomplish the design requirements that are related to low-drag and minimum power operation.
Attributes Effecting Software Testing Estimation; Is Organizational Trust an Issue?
ERIC Educational Resources Information Center
Hammoud, Wissam
2013-01-01
This quantitative correlational research explored the potential association between the levels of organizational trust and the software testing estimation. This was conducted by exploring the relationships between organizational trust, tester's expertise, organizational technology used, and the number of hours, number of testers, and time-coding…
The Sally-Anne test: an interactional analysis of a dyadic assessment.
Korkiakangas, Terhi; Dindar, Katja; Laitila, Aarno; Kärnä, Eija
2016-11-01
The Sally-Anne test has been extensively used to examine children's theory of mind understanding. Many task-related factors have been suggested to impact children's performance on this test. Yet little is known about the interactional aspects of such dyadic assessment situations that might contribute to the ways in which children respond to the test questions. To examine the interactional factors contributing to the performance of two children in the Sally-Anne test. To identify the interactional practices used by the tester administering the task and to describe how interactional features can pose challenges in the critical belief and reality questions for both the tester and the testee. The Sally-Anne test was carried out as part of a project examining children's interactions in a technology-enhanced environment. The present study uses video recordings of two children with communication disorders (one with a current diagnosis of autism spectrum disorder [ASD]) and an adult tester. We draw on a multimodal approach to conversation analysis (CA) to examine the sequential organization of the test questions and answers. The children drew on diverse resources when producing responses to the test questions: responding verbally, pointing or manually handling objects. The tester treated these responses differently depending on how they were produced. When the child pointed at an object and verbally indicated their response, the tester moved on to the next question apparently accepting the child's answer. When the child manually handled an object or produced a quiet verbal response, the tester repeated the question indicating that the child's actions did not constitute an adequate response to a test question. In response to this, both children modified or changed their previous responses. Through monitoring each other, the tester and the child produced actions highly responsive to the features of each other's conduct, which underpinned the conduct of the test itself. Children's responses in the test might not be solely indicative of socio-cognitive capacities but also show orientation to interactional nuances. The study proposes that children can demonstrate diverse ways of responding to questions, yet testers may treat these as test-irrelevant behaviours if they do not correspond to the scoring criteria. A video-based CA study can broaden our understanding of children's pragmatic competencies in responsiveness that may not always embody an expected form. This can have implications for the development of future assessment tasks and revision of existing scoring practices. © 2016 Royal College of Speech and Language Therapists.
Comparison of 3 Methods to Assess Urine Specific Gravity in Collegiate Wrestlers.
Stuempfle, Kristin J.; Drury, Daniel G.
2003-12-01
OBJECTIVE: To investigate the reliability and validity of refractometry, hydrometry, and reagent strips in assessing urine specific gravity in collegiate wrestlers. DESIGN AND SETTING: We assessed the reliability of refractometry, hydrometry, and reagent strips between 2 trials and among 4 testers. The validity of hydrometry and reagent strips was assessed by comparison with refractometry, the criterion measure for urine specific gravity. SUBJECTS: Twenty-one National Collegiate Athletic Association Division III collegiate wrestlers provided fresh urine samples. MEASUREMENTS: Four testers measured the specific gravity of each urine sample 6 times: twice by refractometry, twice by hydrometry, and twice by reagent strips. RESULTS: Refractometer measurements were consistent between trials (R =.998) and among testers; hydrometer measurements were consistent between trials (R =.987) but not among testers; and reagent-strip measurements were not consistent between trials or among testers. Hydrometer (1.018 +/- 0.006) and reagent-strip (1.017 +/- 0.007) measurements were significantly higher than refractometer (1.015 +/- 0.006) measurements. Intraclass correlation coefficients were moderate between refractometry and hydrometry (R =.869) and low between refractometry and reagent strips (R =.573). The hydrometer produced 28% false positives and 2% false negatives, and reagent strips produced 15% false positives and 9% false negatives. CONCLUSIONS: Only the refractometer should be used to determine urine specific gravity in collegiate wrestlers during the weight-certification process.
Grigg, Josephine; Haakonssen, Eric; Rathbone, Evelyne; Orr, Robin; Keogh, Justin W L
2017-11-13
The aim of this study was to quantify the validity and intra-tester reliability of a novel method of kinematic measurement. The measurement target was the joint angles of an athlete performing a BMX Supercross (SX) gate start action through the first 1.2 s of movement in situ on a BMX SX ramp using a standard gate start procedure. The method employed GoPro® Hero 4 Silver (GoPro Inc., USA) cameras capturing data at 120 fps 720 p on a 'normal' lens setting. Kinovea 0.8.15 (Kinovea.org, France) was used for analysis. Tracking data was exported and angles computed in Matlab (Mathworks®, USA). The gold standard 3D method for joint angle measurement could not safely be employed in this environment, so a rigid angle was used. Validity was measured to be within 2°. Intra-tester reliability was measured by the same tester performing the analysis twice with an average of 55 days between analyses. Intra-tester reliability was high, with an absolute error <6° and <9 frames (0.075 s) across all angles and time points for key positions, respectively. The methodology is valid within 2° and reliable within 6° for the calculation of joint angles in the first ~1.25 s.
Comparison of 3 Methods to Assess Urine Specific Gravity in Collegiate Wrestlers
Drury, Daniel G.
2003-01-01
Objective: To investigate the reliability and validity of refractometry, hydrometry, and reagent strips in assessing urine specific gravity in collegiate wrestlers. Design and Setting: We assessed the reliability of refractometry, hydrometry, and reagent strips between 2 trials and among 4 testers. The validity of hydrometry and reagent strips was assessed by comparison with refractometry, the criterion measure for urine specific gravity. Subjects: Twenty-one National Collegiate Athletic Association Division III collegiate wrestlers provided fresh urine samples. Measurements: Four testers measured the specific gravity of each urine sample 6 times: twice by refractometry, twice by hydrometry, and twice by reagent strips. Results: Refractometer measurements were consistent between trials (R = .998) and among testers; hydrometer measurements were consistent between trials (R = .987) but not among testers; and reagent-strip measurements were not consistent between trials or among testers. Hydrometer (1.018 ± 0.006) and reagent-strip (1.017 ± 0.007) measurements were significantly higher than refractometer (1.015 ± 0.006) measurements. Intraclass correlation coefficients were moderate between refractometry and hydrometry (R = .869) and low between refractometry and reagent strips (R = .573). The hydrometer produced 28% false positives and 2% false negatives, and reagent strips produced 15% false positives and 9% false negatives. Conclusions: Only the refractometer should be used to determine urine specific gravity in collegiate wrestlers during the weight-certification process. PMID:14737213
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brackney, L.
Broadly accessible, low cost, accurate, and easy-to-use energy auditing tools remain out of reach for managers of the aging U.S. building population (over 80% of U.S. commercial buildings are more than 10 years old*). concept3D and NREL's commercial buildings group will work to translate and extend NREL's existing spreadsheet-based energy auditing tool for a browser-friendly and mobile-computing platform. NREL will also work with concept3D to further develop a prototype geometry capture and materials inference tool operable on a smart phone/pad platform. These tools will be developed to interoperate with NREL's Building Component Library and OpenStudio energy modeling platforms, and willmore » be marketed by concept3D to commercial developers, academic institutions and governmental agencies. concept3D is NREL's lead developer and subcontractor of the Building Component Library.« less
Rediscovering Morality through the Concept of Childhood
ERIC Educational Resources Information Center
Burdick-Shepherd, Stephanie
2013-01-01
This chapter looks at John Dewey's consideration of childhood as a platform which to view the significance of childhood in moral life. It argues that the concept of childhood is integral to our thinking in the teaching and learning relationship. When we consider childhood from Dewey's platform, we see that childhood is relevant to…
Reduction of Tribocorrosion Products When using the Platform-Switching Concept.
Alrabeah, G O; Knowles, J C; Petridis, H
2018-03-01
The reduced marginal bone loss observed when using the platform-switching concept may be the result of reduced amounts of tribocorrosion products released to the peri-implant tissues. Therefore, the purpose of this study was to compare the tribocorrosion product release from various platform-matched and platform-switched implant-abutment couplings under cyclic loading. Forty-eight titanium implants were coupled with pure titanium, gold alloy, cobalt-chrome alloy, and zirconia abutments forming either platform-switched or platform-matched groups ( n = 6). The specimens were subjected to cyclic occlusal forces in a wet acidic environment for 24 h followed by static aqueous immersion for 6 d. The amount of metal ions released was measured using inductively coupled plasma mass spectrometry. Microscopic evaluations were performed pre- and postimmersion under scanning electron microscope (SEM) equipped with energy-dispersive spectroscopy X-ray for corrosion assessment at the interface and wear particle characterization. All platform-switched groups showed less metal ion release compared with their platform-matched counterparts within each abutment material group ( P < 0.001). Implants connected to platform-matched cobalt-chrome abutments demonstrated the highest total mean metal ion release (218 ppb), while the least total mean ion release (11 ppb) was observed in the implants connected to platform-switched titanium abutments ( P ≤ 0.001). Titanium was released from all test groups, with its highest mean release (108 ppb) observed in the implants connected to platform-matched gold abutments ( P < 0.001). SEM images showed surface tribocorrosion features such as pitting and bands of fretting scars. Wear particles were mostly titanium, ranging from submicron to 48 µm in length. The platform-matched groups demonstrated a higher amount of metal ion release and more surface damage. These findings highlight the positive effect of the platform-switching concept in the reduction of tribocorrosion products released from dental implants, which consequently may minimize the adverse tissue reactions that lead to peri-implant bone loss.
ERIC Educational Resources Information Center
Chagnon, Paul
1996-01-01
Presents activities to determine whether it is better to test dry cells with an ammeter than with a voltmeter and how best to test alkaline batteries. Discusses classification of disposable testers as instruments. Concludes that a laboratory voltmeter gives a good indication of the condition of an alkaline cell while carbon batteries are best…
Long-Term Performance Evaluation of Asphalt Surface Treatments: Product Placement
2010-02-01
20 Wheeler-Sack Army Airfield, Fort Drum , New York ...............................................................28 4...Grip Tester underside view ................................................................................ 6 Figure 3. Rotating disc of Dynamic...measures pavement friction using the braked -wheel, fixed-slip principle. Two wheels support the Grip Tester on a drive axle, while a measuring wheel with
NASA Astrophysics Data System (ADS)
Eckhardt, Matt
2014-03-01
Tunneling spectroscopy is an important technique used to measure the superconducting energy gap, a feature that is at the heart of the nature of superconductivity in various materials. In this presentation, we report the progress and results in developing high-resolution tunneling spectroscopy experimental platforms in a helium three cryostat, a 3 Kelvin cryocooler and a helium dip-tester. The experimental team working in a liberal arts university is a multi-disciplinary group consisting of one physics major, chemisty majors and a biology major. Students including non-physics majors learned and implemented current-voltage measurement techniques, vacuum system engineering, built electronic boxes and amplifier circuits from scratch, built custom multi-conductor cables for thermometry and current-voltage measurements, and performed conductance measurements. We report preliminary results. Acknowledgments: We acknowledge support from National Science Foundation Grant # DMR-1206561.
NASA Astrophysics Data System (ADS)
Luhur, H. S.; Widjaja, N. D.
2014-03-01
This paper is focusing on the development of a mobile application for searching restaurants and promotions with location based and social networking features. The main function of the application is to search restaurant information. Other functions are also available in this application such as add restaurant, add promotion, add photo, add food review, and other features including social networking features. The restaurant and promotion searching application will be developed under Android platform. Upon completion of this paper, heuristic evaluation and usability testing have been conducted. The result of both testing shows that the application is highly usable. Even though there are some usability problems discovered, the problems can be eliminated immediately by implementing the recommendations from the expert evaluators and the users as the testers of the application. Further improvement made to the application will ensure that the application can really be beneficial for the users of the application.
NASA Astrophysics Data System (ADS)
Rau, T. H.
1982-06-01
The MB-3 Tester is an electric motor-driven cabin leakage tester designed to furnish pressurized air to the aircraft at controlled pressures and temperatures during ground pressurization of aircraft cockpits and pressurized compartments. This report provides measured data defining the bioacoustic environments produced by this unit operating at a normal rated/load condition. Near-field data are reported for 37 locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise level, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors.
Concepts for a geostationary-like polar mission
NASA Astrophysics Data System (ADS)
Macdonald, Malcolm; Anderson, Pamela; Carrea, Laura; Dobke, Benjamin; Embury, Owen; Merchant, Chris; Bensi, Paolo
2014-10-01
An evidence-led scientific case for development of a space-based polar remote sensing platform at geostationary-like (GEO-like) altitudes is developed through methods including a data user survey. Whilst a GEO platform provides a nearstatic perspective, multiple platforms are required to provide circumferential coverage. Systems for achieving GEO-like polar observation likewise require multiple platforms however the perspective is non-stationery. A key choice is between designs that provide complete polar view from a single platform at any given instant, and designs where this is obtained by compositing partial views from multiple sensors. Users foresee an increased challenge in extracting geophysical information from composite images and consider the use of non-composited images advantageous. Users also find the placement of apogee over the pole to be preferable to the alternative scenarios. Thus, a clear majority of data users find the "Taranis" orbit concept to be better than a critical inclination orbit, due to the improved perspective offered. The geophysical products that would benefit from a GEO-like polar platform are mainly estimated from radiances in the visible/near infrared and thermal parts of the electromagnetic spectrum, which is consistent with currently proven technologies from GEO. Based on the survey results, needs analysis, and current technology proven from GEO, scientific and observation requirements are developed along with two instrument concepts with eight and four channels, based on Flexible Combined Imager heritage. It is found that an operational system could, mostly likely, be deployed from an Ariane 5 ES to a 16-hour orbit, while a proof-of-concept system could be deployed from a Soyuz launch to the same orbit.
Communications platform payload definition study
NASA Technical Reports Server (NTRS)
Clopp, H. W.; Hawkes, T. A.; Bertles, C. R.; Pontano, B. A.; Kao, T.
1986-01-01
Large geostationary communications platforms were investigated in a number of studies since 1974 as a possible means to more effectively utilize the geostationary arc and electromagnetic spectrum and to reduce overall satellite communications system costs. The commercial feasibility of various communications platform payload concepts circa 1998 was addressed. Promising payload concepts were defined, recurring costs were estimated, and critical technologies needed to enable eventual commercialization were identified. Ten communications service aggregation scenarios describing potential groupings of service were developed for a range of conditions. Payload concepts were defined for four of these scenarios: (1) Land Mobile Satellite Service (LMSS) meets 100% of Contiguous United States (CONUS) plus Canada demand with a single platform; (2) Fixed Satellite Service (FSS) (trunking + Customer Premises Service (CPS)), meet 20% of CONUS demand;(3) FSS (trunking + CPS + video distribution), 10 to 13% of CONUS demand; and (4) FSS (20% of demand) + Inter Satellite Links (ISL) + Tracking and Data Relay Satellite System (TDRSS)/Tracking and Data Acquisition System (TDAS) Data Distribution.
49 CFR 229.25 - Tests: Every periodic inspection.
Code of Federal Regulations, 2011 CFR
2011-10-01
... dead-weight tester or a test gauge designed for this purpose. (b) All electrical devices and visible...) Steam pressure gauges shall be tested by comparison with a dead-weight tester or a test gauge designed... 49 Transportation 4 2011-10-01 2011-10-01 false Tests: Every periodic inspection. 229.25 Section...
DOT National Transportation Integrated Search
2000-08-01
Traffic signal system controllers designed to meet the NEMA TS1 Standards are one of the most prevalent types in use in the US and Canada as of this writing. A PC-based tester for testing NEMA TS1 traffic signal controllers has been developed as a pa...
DOT National Transportation Integrated Search
2000-08-01
Traffic signal system controllers designed to meet the NEMA TS1 Standards are one of the most prevalent types in use in the US and Canada as of this writing. A PC-based tester for testing NEMA TS1 traffic signal controllers has been developed as a pa...
Usefulness of new wetness tester for diagnosis of dry mouth in disabled patients.
Kakinoki, Yasuaki; Nishihara, Tatsuji; Arita, Masahiro; Shibuya, Koji; Ishikawa, Masao
2004-12-01
The condition of dry mouth is an influential factor in the incidence of caries, periodontal disease, fungal infections, masticatory dysfunctions and denture function. Bedridden elderly and disabled persons often suffer from oral dryness and the aim of this study was to evaluate the usefulness of measuring the amount of moisture in the oral mucosa for clinical diagnosis of dry mouth in this group. The subjects were 20 elderly bedridden individuals, age range 65-89 years old, living in a nursing home and six healthy laboratory researchers, aged 20-46 years old, used as controls. Tongue dorsum moisture measurements were performed using a newly developed wetness tester (L-SALIVO), in which the wet portion was measured after 10 s. Further, clinical diagnosis of dry mouth was carried out using a clinical classification scale of the tongue mucosa (grade range, 0-3). It was possible to measure tongue dorsum moisture in all subjects with the wetness tester. The average moisture value was 0.1+/-0.2 mm in elderly subjects with a dry mouth grade of 2 (n = 8) or 3 (n = 12), while the average moisture value in the control subjects was 3.67+/-1.75 mm with a dry mouth grade of 0 (n = 4) or 1 (n = 2). Tester values and cliniical classification showed a positive co-relationship (r = 0.31, p < 0.05). Our results show that this new tester could be useful for evaluating oral dryness and diagnosing dry mouth.
Concept Development of the Eindhoven Diabetes Education Simulator Project.
Maas, Anne H; van der Molen, Pieta; van de Vijver, Reinier; Chen, Wei; van Pul, Carola; Cottaar, Eduardus J E; van Riel, Natal A W; Hilbers, Peter A J; Haak, Harm R
2016-04-01
This study was designed to define the concept of an educational diabetes game following a user-centered design approach. The concept development of the Eindhoven Diabetes Education Simulator (E-DES) project can be divided in two phases: concept generation and concept evaluation. Four concepts were designed by the multidisciplinary development team based on the outcomes of user interviews. Four other concepts resulted from the Diabetes Game Jam. Several users and experts evaluated the concepts. These user evaluations and a feasibility analysis served as input for an overall evaluation and discussion by the development team resulting in the final concept choice. The four concepts of the development team are a digital board game, a quiz platform, a lifestyle simulator, and a puzzle game. The Diabetes Game Jam resulted in another digital board game, two mobile swipe games, and a fairy tale-themed adventure game. The combined user evaluations and feasibility analysis ranked the quiz platform and the digital board game equally high. Each of these games fits one specific subgroup of users best: the quiz platform best fits an eager-to-learn, more individualistic patient, whereas the board game best fits a less-eager-to-learn, family-oriented patient. The choice for a specific concept is therefore highly dependent on the choice of our specific target audience. The user-centered design approach with multiple evaluations has enabled us to choose the most promising concept from eight different options. A digital board game is chosen for further development because the target audience for E-DES is the less-motivated, family-oriented patients.
Robotic vehicle mobility and task performance: A flexible control modality for manned systems
NASA Technical Reports Server (NTRS)
Eldredge, Frederick
1994-01-01
In the early 1980's, a number of concepts were developed for applying robotics to ground systems. The majority of these early application concepts envisioned robotics technology embedded in dedicated unmanned systems; i.e., unmanned systems with no provision for direct manned control of the platform. Although these concepts offered advantages peculiar to platforms designed from the outset exclusively for unmanned operation--i.e., no crew compartment--their findings would require costs and support for a new class of unmanned systems. The current era of reduced budgets and increasing focus on rapid force projection has created new opportunities to examine the value of an alternative concept: the use of existing manned platforms with an ability to quickly shift from normal manned operation to unmanned should a particularly harzardous situation arise. The author of this paper addresses the evolution of robotic vehicle concepts and technology testbeds from exclusively unmanned systems to a variety of 'optionally manned' systems which have been designed with minimum intrusion actuator and control equipment to minimize degradation of vehicle performance in manned modes of operation.
SU-F-E-18: Training Monthly QA of Medical Accelerators: Illustrated Instructions for Self-Learning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Court, L; Wang, H; Aten, D
Purpose: To develop and test clear illustrated instructions for training of monthly mechanical QA of medical linear accelerators. Methods: Illustrated instructions were created for monthly mechanical QA with tolerance tabulated, and underwent several steps of review and refinement. Testers with zero QA experience were then recruited from our radiotherapy department (1 student, 2 computational scientists and 8 dosimetrists). The following parameters were progressively de-calibrated on a Varian C-series linac: Group A = gantry angle, ceiling laser position, X1 jaw position, couch longitudinal position, physical graticule position (5 testers); Group B = Group A + wall laser position, couch lateral andmore » vertical position, collimator angle (3 testers); Group C = Group B + couch angle, wall laser angle, and optical distance indicator (3 testers). Testers were taught how to use the linac, and then used the instructions to try to identify these errors. A physicist observed each session, giving support on machine operation, as necessary. The instructions were further tested with groups of therapists, graduate students and physics residents at multiple institutions. We have also changed the language of the instructions to simulate using the instructions with non-English speakers. Results: Testers were able to follow the instructions. They determined gantry, collimator and couch angle errors within 0.4, 0.3, and 0.9degrees of the actual changed values, respectively. Laser positions were determined within 1mm, and jaw positions within 2mm. Couch position errors were determined within 2 and 3mm for lateral/longitudinal and vertical errors, respectively. Accessory positioning errors were determined within 1mm. ODI errors were determined within 2mm when comparing with distance sticks, and 6mm when using blocks, indicating that distance sticks should be the preferred approach for inexperienced staff. Conclusion: Inexperienced users were able to follow these instructions, and catch errors within the criteria suggested by AAPM TG142 for linacs used for IMRT.« less
Longin, C Friedrich H; Utz, H Friedrich; Melchinger, Albrecht E; Reif, Jochen C
2007-02-01
Optimum allocation of test resources is of crucial importance for the efficiency of breeding programs. Our objectives were to (1) determine the optimum allocation of the number of lines, test locations, as well as number and type of testers in hybrid maize breeding using doubled haploids with two breeding strategies for improvement of general combining ability (GCA), (2) compare the maximum selection gain (DeltaG) achievable under both strategies, and (3) give recommendations for the optimum implementation of doubled haploids in commercial hybrid maize breeding. We calculated DeltaG by numerical integration for two two-stage selection strategies with evaluation of (1) testcross performance in both stages (BS1) or (2) line per se performance in the first stage followed by testcross performance in the second stage (BS2). Different assumptions were made regarding the budget, variance components (VCs), and the correlation between line per se performance and GCA. Selection gain for GCA increased with a broader genetic base of the tester. Hence, testers combining a large number of divergent lines are advantageous. However, in applied breeding programs, the use of single- or double-cross testers in the first and inbred testers in the second selection stage may be a good compromise between theoretical and practical requirements. With a correlation between line per se performance and GCA of 0.50, DeltaG for BS1 is about 5% higher than for BS2, if an economic weight of line per se performance is neglected. With increasing economic weight of line per se performance, relative efficiency of BS2 increased rapidly resulting in a superiority of BS2 over BS1 already for an economic weight for line per se performance larger than 0.1. Considering the importance of an economic seed production, an economic weight larger than 0.1 seems realistic indicating the necessity of separate breeding strategies for seed and pollen parent heterotic groups.
Experimental validation of docking and capture using space robotics testbeds
NASA Technical Reports Server (NTRS)
Spofford, John
1991-01-01
Docking concepts include capture, berthing, and docking. The definitions of these terms, consistent with AIAA, are as follows: (1) capture (grasping)--the use of a manipulator to make initial contact and attachment between transfer vehicle and a platform; (2) berthing--positioning of a transfer vehicle or payload into platform restraints using a manipulator; and (3) docking--propulsive mechanical connection between vehicle and platform. The combination of the capture and berthing operations is effectively the same as docking; i.e., capture (grasping) + berthing = docking. These concepts are discussed in terms of Martin Marietta's ability to develop validation methods using robotics testbeds.
Venus Atmospheric Maneuverable Platform (VAMP) - A Low Cost Venus Exploration Concept
NASA Astrophysics Data System (ADS)
Lee, G.; Polidan, R. S.; Ross, F.
2015-12-01
The Northrop Grumman Aerospace Systems and L-Garde team has been developing an innovative mission concept: a long-lived, maneuverable platform to explore the Venus upper atmosphere. This capability is an implementation of our Lifting Entry Atmospheric Flight (LEAF) system concept, and the Venus implementation is called the Venus Atmospheric Maneuverable Platform (VAMP). The VAMP concept utilizes an ultra-low ballistic coefficient (< 50 Pa), semi-buoyant aircraft that deploys prior to entering the Venus atmosphere, enters without an aeroshell, and provides a long-lived (months to a year) maneuverable vehicle capable of carrying science instruments to explore the Venus upper atmosphere. In this presentation we provide an update on the air vehicle design and a low cost pathfinder mission concept that can be implemented in the near-term. The presentation also provides an overview of our plans for future trade studies, analyses, and prototyping to advance and refine the concept. We will discuss the air vehicle's entry concepts of operations (CONOPs) and atmospheric science operations. We will present a strawman concept of a VAMP pathfinder, including ballistic coefficient, planform area, percent buoyancy, wing span, vehicle mass, power supply, propulsion, materials considerations, structural elements, and instruments accommodation. In this context, we will discuss the following key factors impacting the design and performance of VAMP: Entry into the Venus atmosphere, including descent profile, heating rate, total heat load, stagnation, and acreage temperatures Impact of maximum altitude on air vehicle design and entry heating Candidate thermal protection system (TPS) requirements We will discuss the interdependencies of the above factors and the manner in which the VAMP pathfinder concept's characteristics affect the CONOPs and the science objectives. We will show how the these factors provide constraints as well as enable opportunities for novel long duration scientific studies of the Venus upper atmosphere that support Venus science goals. We will also discuss how the VAMP platform itself can facilitate some of these science measurements.
49 CFR 173.120 - Class 3-Definitions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Closed Cup Tester, (ASTM D 56) (IBR; see § 171.7 of this subchapter); (B) Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus, (ASTM D 3278) (IBR; see § 171.7 of this subchapter... for Flash Point by Pensky-Martens Closed Cup Tester, (ASTM D 93) (IBR; see § 171.7 of this subchapter...
Loopback Tester: a synchronous communications circuit diagnostic device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maestas, J.H.
1986-07-01
The Loopback Tester is an Intel SBC 86/12A Single Board Computer and an Intel SBC 534 Communications Expansion Board configured and programmed to perform various basic or less. These tests include: (1) Data Communications Equipment (DCE) transmit timing detection (2) data rate measurement (3) instantaneous loopback indication and (4) bit error rate testing. It requires no initial setup after plug in, and can be used to locate the source of communications loss in a circuit. It can also be used to determine when crypto variable mismatch problems are the source of communications loss. This report discusses the functionality of themore » Loopback Tester as a diagnostic device. It also discusses the hardware and software which implements this simple yet reliable device.« less
Geostationary platform systems concepts definition study. Volume 2A: Appendixes, book 2
NASA Technical Reports Server (NTRS)
1980-01-01
Various investigations and support data concerning geostationary platform feasibility are presented. Servicing flight analyses, platform cost model runs, and funding spread analyses are included. In addition, investigations of the radiation environment at synchronous altitude and its effects on satellite communication are reported.
2016-09-01
and network. The computing and network hardware are identified and include routers, servers, firewalls, laptops , backup hard drives, smart phones...deployable hardware units will be necessary. This includes the use of ruggedized laptops and desktop computers , a projector system, communications system...ENGINEERING STUDY AND CONCEPT DEVELOPMENT FOR A HUMANITARIAN AID AND DISASTER RELIEF OPERATIONS MANAGEMENT PLATFORM by Julie A. Reed September
Yang, T.S.; Yao, S.H.; Chang, Y.Y.; Deng, J.H.
2018-01-01
Hard coatings have been adopted in cutting and forming applications for nearly two decades. The major purpose of using hard coatings is to reduce the friction coefficient between contact surfaces, to increase strength, toughness and anti-wear performance of working tools and molds, and then to obtain a smooth work surface and an increase in service life of tools and molds. In this report, we deposited a composite CrTiSiN hard coating, and a traditional single-layered TiAlN coating as a reference. Then, the coatings were comparatively studied by a series of tests. A field emission SEM was used to characterize the microstructure. Hardness was measured using a nano-indentation tester. Adhesion of coatings was evaluated using a Rockwell C hardness indentation tester. A pin-on-disk wear tester with WC balls as sliding counterparts was used to determine the wear properties. A self-designed compression and friction tester, by combining a Universal Testing Machine and a wear tester, was used to evaluate the contact behavior of composite CrTiSiN coated dies in compressing of Mg alloy sheets under high pressure. The results indicated that the hardness of composite CrTiSiN coating was lower than that of the TiAlN coating. However, the CrTiSiN coating showed better anti-wear performance. The CrTiSiN coated dies achieved smooth surfaces on the Mg alloy sheet in the compressing test and lower friction coefficient in the friction test, as compared with the TiAlN coating. PMID:29316687
Three-dimensional measurement of yarn hairiness via multiperspective images
NASA Astrophysics Data System (ADS)
Wang, Lei; Xu, Bugao; Gao, Weidong
2018-02-01
Yarn hairiness is one of the essential parameters for assessing yarn quality. Most of the currently used yarn measurement systems are based on two-dimensional (2-D) photoelectric measurements, which are likely to underestimate levels of yarn hairiness because hairy fibers on a yarn surface are often projected or occluded in these 2-D systems. A three-dimensional (3-D) test method for hairiness measurement using a multiperspective imaging system is presented. The system was developed to reconstruct a 3-D yarn model for tracing the actual length of hairy fibers on a yarn surface. Five views of a yarn from different perspectives were created by two angled mirrors and simultaneously captured in one panoramic picture by a camera. A 3-D model was built by extracting the yarn silhouettes in the five views and transferring the silhouettes into a common coordinate system. From the 3-D model, curved hair fibers were traced spatially so that projection and occlusion occurring in the current systems could be avoided. In the experiment, the proposed method was compared with two commercial instruments, i.e., the Uster Tester and Zweigle Tester. It is demonstrated that the length distribution of hairy fibers measured from the 3-D model showed an exponential growth when the fiber length is sorted from shortest to longest. The hairiness measurements, such as H-value, measured by the multiperspective method were highly consistent with those of Uster Tester (r=0.992) but had larger values than those obtained from Uster Tester and Zweigle Tester, proving that the proposed method corrected underestimated hairiness measurements in the commercial systems.
Yang, T S; Yao, S H; Chang, Y Y; Deng, J H
2018-01-08
Hard coatings have been adopted in cutting and forming applications for nearly two decades. The major purpose of using hard coatings is to reduce the friction coefficient between contact surfaces, to increase strength, toughness and anti-wear performance of working tools and molds, and then to obtain a smooth work surface and an increase in service life of tools and molds. In this report, we deposited a composite CrTiSiN hard coating, and a traditional single-layered TiAlN coating as a reference. Then, the coatings were comparatively studied by a series of tests. A field emission SEM was used to characterize the microstructure. Hardness was measured using a nano-indentation tester. Adhesion of coatings was evaluated using a Rockwell C hardness indentation tester. A pin-on-disk wear tester with WC balls as sliding counterparts was used to determine the wear properties. A self-designed compression and friction tester, by combining a Universal Testing Machine and a wear tester, was used to evaluate the contact behavior of composite CrTiSiN coated dies in compressing of Mg alloy sheets under high pressure. The results indicated that the hardness of composite CrTiSiN coating was lower than that of the TiAlN coating. However, the CrTiSiN coating showed better anti-wear performance. The CrTiSiN coated dies achieved smooth surfaces on the Mg alloy sheet in the compressing test and lower friction coefficient in the friction test, as compared with the TiAlN coating.
Pressure measurements of a three wave journal air bearing
NASA Technical Reports Server (NTRS)
Dimofte, Florin; Addy, Harold E., Jr.
1994-01-01
In order to validate theoretical predictions of a wave journal bearing concept, a bench test rig was assembled at NASA Lewis Research Center to measure the steady-state performance of a journal air bearing. The tester can run up to 30,000 RPM and the spindle has a run out of less than 1 micron. A three wave journal bearing (50 mm diameter and 58 mm length) has been machined at NASA Lewis. The pressures at 16 ports along the bearing circumference at the middle of the bearing length were measured and compared to the theoretical prediction. The bearing ran at speeds up to 15,000 RPM and certain loads. Good agreement was found between the measured and calculated pressures.
Security From Detection (Vehicles)
2011-02-24
Tester ( TVT ) or other TOP 02-2-615A 24 February 2011 5 similar device. Color vision can be assessed using the seven Ishihara Pseudo...Isochromatic plates usually contained in the TVT . b. Personnel chosen as observers for aural detectability tests must also have hearing ability...Test Test Measurement Diagnostic Equipment TOP Test Operations Procedure TVT Titmus® Vision Tester USMC United States Marine Corps
Security from Detection (Vehicles)
2011-02-24
Tester ( TVT ) or other TOP 02-2-615A 24 February 2011 5 similar device. Color vision can be assessed using the seven Ishihara Pseudo...Isochromatic plates usually contained in the TVT . b. Personnel chosen as observers for aural detectability tests must also have hearing ability...Test Test Measurement Diagnostic Equipment TOP Test Operations Procedure TVT Titmus® Vision Tester USMC United States Marine Corps
An automated data collection system for a Charpy impact tester
NASA Technical Reports Server (NTRS)
Weigman, Bernard J.; Spiegel, F. Xavier
1993-01-01
A method for automated data collection has been developed for a Charpy impact tester. A potentiometer is connected to the pivot point of the hammer and measures the angular displacement of the hammer. This data is collected with a computer and, through appropriate software, accurately records the energy absorbed by the specimen. The device can be easily calibrated with minimal effort.
The Design of a Four Square Gear Tester for Noise and Vibration Measurements.
1986-12-01
Four Square Gear Tester ...... . 25 2.3 The Speed-Torque Relationship of Contraves Blower Ventilated Motor ....... ..................... ... 31 2.4...The Speed-Torque Relationship of Contraves Self- Ventilated Motor ....... ..................... ... 32 2.5 The Contraves Motor...34 2.6 The Contraves Motor Mounted Blower ... ............ ... 35 2.7 The Fixed-Fixed End Condition (to determine the natural frequency of the
NASA Astrophysics Data System (ADS)
Abd Rashid, Amirul; Hayati Saad, Nor; Bien Chia Sheng, Daniel; Yee, Lee Wai
2014-06-01
PH value is one of the important variables for tungsten trioxide (WO3) nanostructure hydrothermal synthesis process. The morphology of the synthesized nanostructure can be properly controlled by measuring and controlling the pH value of the solution used in this facile synthesis route. Therefore, it is very crucial to ensure the gauge used for pH measurement is reliable in order to achieve the expected result. In this study, gauge repeatability and reproducibility (GR&R) method was used to assess the repeatability and reproducibility of the pH tester. Based on ANOVA method, the design of experimental metrics as well as the result of the experiment was analyzed using Minitab software. It was found that the initial GR&R value for the tester was at 17.55 % which considered as acceptable. To further improve the GR&R level, a new pH measuring procedure was introduced. With the new procedure, the GR&R value was able to be reduced to 2.05%, which means the tester is statistically very ideal to measure the pH of the solution prepared for WO3 hydrothermal synthesis process.
de Lima, V J; do Amaral Junior, A T; Kamphorst, S H; Pena, G F; Leite, J T; Schmitt, K F M; Vittorazzi, C; de Almeida Filho, J E; Mora, F
2016-12-02
The successful development of hybrid cultivars depends on the reliability of estimated combining ability of the parent lines. The objectives of this study were to assess the combining ability of partially inbred S 3 families of popcorn derived from the open-pollinated variety UENF 14, via top-crosses with four testers, and to compare the testers for their ability to discriminate the S 3 progenies. The experiment was conducted in the 2015/2016 crop season, in an incomplete-block (Lattice) design with three replications. The following agronomic traits were evaluated: average plant height, grain yield (GY), popping expansion (PE), and expanded popcorn volume per hectare. The top-cross hybrid, originating from the BRS-Angela vs S 3 progeny 10 combination, was indicated as promising, showing high values for specific combining ability for GY and PE. For the S 3 progenies that showed high and positive GCA values for GY and PE, the continuity of the breeding program is recommended, with the advance of self-pollination generations. Fasoulas' differentiation index discriminated the BRS-Angela tester as the most suitable for identifying the superior progenies.
Reliability and Concurrent Validity of Dynamic Rotator Stability Test-A Cross Sectional study.
Binoy Mathew, K V; Eapen, Charu; Kumar, P Senthil
2012-01-01
To find intra rater and inter rater reliability of Dynamic Rotator Stability Test (DRST) and to find concurrent validity of Dynamic Rotator Stability Test (DRST) with University of Pennsylvania Shoulder Score (PENN) Scale. 40 subjects of either gender between the age group of 18-70 with painful shoulder conditions of musculoskeletal origin was selected through convenient sampling. Tester 1 and tester 2 administered DRST and PENN scale randomly. In a subgroup of 20 subjects DRST was administered by both the testers to find the inter rater reliability. 180° Standard Universal Goniometer was used to take measurements. For intra-rater reliability, all the test variables were showing highly significant correlation (p=.94 - 1). For inter -rater, with tester 2, test variables like position, ROM, force, direction of abnormal translation, pain during the test, compensatory movement during test were found to be significant (p=.71-1).only some variables of DRST showed significant correlation with PENN scale (P=.320-.450). Dynamic Rotator Stability Test has good intra rater and moderate inter rater reliability. Concurrent validity of Dynamic Rotator Stability Test was found to be poor when compared to PENN Shoulder Score.
Test-retest reliability of auditory brainstem responses to chirp stimuli in newborns.
Cobb, Kensi M; Stuart, Andrew
2014-11-01
The purpose of this study was to examine the test-retest reliability of auditory brainstem responses (ABRs) to air- and bone-conducted chirp stimuli in newborns as a function of intensity. A repeated measures quasi-experimental design was employed. Thirty healthy newborns participated. ABRs were evoked using 60, 45, and 30 dB nHL air-conducted CE-Chirps and 45, 30, and 15 dB nHL bone-conducted CE-Chirps at a rate of 57.7/s. Measures were repeated by a second tester. Statistically significant correlations (p <.0001) and predictive linear relations (p <.0001) were found between testers for wave V latencies and amplitudes to air- and bone-conducted CE-Chirps. There were also no statistically significant differences between testers with wave V latencies and amplitudes to air- and bone-conducted CE-Chirps (p >.05). As expected, significant differences in wave V latencies and amplitudes were seen as a function of stimulus intensity for air- and bone-conducted CE-Chirps (p <.0001). These results suggest that ABRs to air- and bone-conducted CE-Chirps can be reliably repeated in newborns with different testers. The CE-Chirp may be valuable for both screening and diagnostic audiologic assessments of newborns.
Study of data collection platform concepts: Data collection system user requirements
NASA Technical Reports Server (NTRS)
1973-01-01
The overall purpose of the survey was to provide real world data on user requirements. The intent was to assess data collection system user requirements by questioning actual potential users rather than speculating on requirements. The end results of the survey are baseline requirements models for both a data collection platform and a data collection system. These models were derived from the survey results. The real value of these models lies in the fact that they are based on actual user requirements as delineated in the survey questionnaires. Some users desire data collection platforms of small size and light weight. These sizes and weights are beyond the present state of the art. Also, the survey provided a wealth of information on the nature and constituency of the data collection user community as well as information on user applications for data collection systems. Finally, the data sheds light on the generalized platform concept. That is, the diversity of user requirements shown in the data indicates the difficulty that can be anticipated in attempting to implement such a concept.
Shukla, Krishna Dayal; Saxena, Nishant; Manivannan, Anbarasu
2017-12-01
Recent advancements in commercialization of high-speed non-volatile electronic memories including phase change memory (PCM) have shown potential not only for advanced data storage but also for novel computing concepts. However, an in-depth understanding on ultrafast electrical switching dynamics is a key challenge for defining the ultimate speed of nanoscale memory devices that demands for an unconventional electrical setup, specifically capable of handling extremely fast electrical pulses. In the present work, an ultrafast programmable electrical tester (PET) setup has been developed exceptionally for unravelling time-resolved electrical switching dynamics and programming characteristics of nanoscale memory devices at the picosecond (ps) time scale. This setup consists of novel high-frequency contact-boards carefully designed to capture extremely fast switching transient characteristics within 200 ± 25 ps using time-resolved current-voltage measurements. All the instruments in the system are synchronized using LabVIEW, which helps to achieve various programming characteristics such as voltage-dependent transient parameters, read/write operations, and endurance test of memory devices systematically using short voltage pulses having pulse parameters varied from 1 ns rise/fall time and 1.5 ns pulse width (full width half maximum). Furthermore, the setup has successfully demonstrated strikingly one order faster switching characteristics of Ag 5 In 5 Sb 60 Te 30 (AIST) PCM devices within 250 ps. Hence, this novel electrical setup would be immensely helpful for realizing the ultimate speed limits of various high-speed memory technologies for future computing.
NASA Astrophysics Data System (ADS)
Shukla, Krishna Dayal; Saxena, Nishant; Manivannan, Anbarasu
2017-12-01
Recent advancements in commercialization of high-speed non-volatile electronic memories including phase change memory (PCM) have shown potential not only for advanced data storage but also for novel computing concepts. However, an in-depth understanding on ultrafast electrical switching dynamics is a key challenge for defining the ultimate speed of nanoscale memory devices that demands for an unconventional electrical setup, specifically capable of handling extremely fast electrical pulses. In the present work, an ultrafast programmable electrical tester (PET) setup has been developed exceptionally for unravelling time-resolved electrical switching dynamics and programming characteristics of nanoscale memory devices at the picosecond (ps) time scale. This setup consists of novel high-frequency contact-boards carefully designed to capture extremely fast switching transient characteristics within 200 ± 25 ps using time-resolved current-voltage measurements. All the instruments in the system are synchronized using LabVIEW, which helps to achieve various programming characteristics such as voltage-dependent transient parameters, read/write operations, and endurance test of memory devices systematically using short voltage pulses having pulse parameters varied from 1 ns rise/fall time and 1.5 ns pulse width (full width half maximum). Furthermore, the setup has successfully demonstrated strikingly one order faster switching characteristics of Ag5In5Sb60Te30 (AIST) PCM devices within 250 ps. Hence, this novel electrical setup would be immensely helpful for realizing the ultimate speed limits of various high-speed memory technologies for future computing.
Automated Platform Management System Scheduling
NASA Technical Reports Server (NTRS)
Hull, Larry G.
1990-01-01
The Platform Management System was established to coordinate the operation of platform systems and instruments. The management functions are split between ground and space components. Since platforms are to be out of contact with the ground more than the manned base, the on-board functions are required to be more autonomous than those of the manned base. Under this concept, automated replanning and rescheduling, including on-board real-time schedule maintenance and schedule repair, are required to effectively and efficiently meet Space Station Freedom mission goals. In a FY88 study, we developed several promising alternatives for automated platform planning and scheduling. We recommended both a specific alternative and a phased approach to automated platform resource scheduling. Our recommended alternative was based upon use of exactly the same scheduling engine in both ground and space components of the platform management system. Our phased approach recommendation was based upon evolutionary development of the platform. In the past year, we developed platform scheduler requirements and implemented a rapid prototype of a baseline platform scheduler. Presently we are rehosting this platform scheduler rapid prototype and integrating the scheduler prototype into two Goddard Space Flight Center testbeds, as the ground scheduler in the Scheduling Concepts, Architectures, and Networks Testbed and as the on-board scheduler in the Platform Management System Testbed. Using these testbeds, we will investigate rescheduling issues, evaluate operational performance and enhance the platform scheduler prototype to demonstrate our evolutionary approach to automated platform scheduling. The work described in this paper was performed prior to Space Station Freedom rephasing, transfer of platform responsibility to Code E, and other recently discussed changes. We neither speculate on these changes nor attempt to predict the impact of the final decisions. As a consequence some of our work and results may be outdated when this paper is published.
Influence of platform switching on bone-level alterations: a three-year randomized clinical trial.
Enkling, N; Jöhren, P; Katsoulis, J; Bayer, S; Jervøe-Storm, P-M; Mericske-Stern, R; Jepsen, S
2013-12-01
The concept of platform switching has been introduced to implant dentistry based on clinical observations of reduced peri-implant crestal bone loss. However, published data are controversial, and most studies are limited to 12 months. The aim of the present randomized clinical trial was to test the hypothesis that platform switching has a positive impact on crestal bone-level changes after 3 years. Two implants with a diameter of 4 mm were inserted crestally in the posterior mandible of 25 patients. The intraindividual allocation of platform switching (3.3-mm platform) and the standard implant (4-mm platform) was randomized. After 3 months of submerged healing, single-tooth crowns were cemented. Patients were followed up at short intervals for monitoring of healing and oral hygiene. Statistical analysis for the influence of time and platform type on bone levels employed the Brunner-Langer model. At 3 years, the mean radiographic peri-implant bone loss was 0.69 ± 0.43 mm (platform switching) and 0.74 ± 0.57 mm (standard platform). The mean intraindividual difference was 0.05 ± 0.58 mm (95% confidence interval: -0.19, 0.29). Crestal bone-level alteration depended on time (p < .001) but not on platform type (p = .363). The present randomized clinical trial could not confirm the hypothesis of a reduced peri-implant crestal bone loss, when implants had been restored according to the concept of platform switching.
Evaluation of Next-Generation Vision Testers for Aeromedical Certification of Aviation Personnel
2009-07-01
measure distant, intermediate, and near acuity. The slides are essentially abbreviated versions of the Early Treatment for Diabetic Retinopathy Study...over, requiring intermediate vision testing and 12 were color deficient. Analysis was designed to detect statistically significant differences between...Vertical Phoria (Right & Left Hyperphoria) Test scores from each of the vision testers were collated and analyzed. Analysis was designed to detect
NASA five-ball fatigue tester: Over 20 years of research
NASA Technical Reports Server (NTRS)
Zaretsky, E. V.; Parker, R. J.; Anderson, W. J.
1981-01-01
Studies were conducted to determine the effect on rolling-element fatigue life of contact angle, material hardness, chemistry, heat treatment and processing, lubricant type and chemistry, elastohydrodynamic film thickness, deformation and wear, vacuum, and temperature as well as Hertzian and residual stresses. Correlation was established between the results obtained using the five-ball tester and those obtained with full scale rolling-element bearings.
Construction concept for erecting an offset-fed antenna
NASA Technical Reports Server (NTRS)
Rhodes, M. D.
1984-01-01
A design concept for the construction of an offset-fed antenna is discussed. Antennas of this type are of interest for space applications because the configuration eliminates the effects of feed and feed-support blockage. The proposed construction concept is developed around the assembly of a stiff truss substructure by pressure-suited astronauts operating in extravehicular activity (EVA) assisted by a mobile platform that moves along the structure to position the astronauts at joint locations where they can latch members in place. Construction can be accomplished from the shuttle cargo bay in the course of a normal flight or from a space station platform. The concepts demonstrates the versatility of machine assisted manned assembly and is only one of many potential applications.
Lee, Yong Yi; Meurk, Carla S; Harris, Meredith G; Diminic, Sandra; Scheurer, Roman W; Whiteford, Harvey A
2014-11-26
Ensuring that a mental health system provides 'value for money' requires policy makers to allocate resources to the most cost-effective interventions. Organizing cost-effective interventions into a service delivery framework will require a concept that can guide the mapping of evidence regarding disorder-level interventions to aggregations of services that are meaningful for policy makers. The 'service platform' is an emerging concept that could be used to this end, however no explicit definition currently exists in the literature. The aim of this study was to develop a service platform definition that is consistent with how policy makers conceptualize the major elements of the mental health service system and to test the validity and utility of this definition through consultation with mental health policy makers. We derived a provisional definition informed by existing literature and consultation with experienced mental health researchers. Using a modified Delphi method, we obtained feedback from nine Australian policy makers. Respondents provided written answers to a questionnaire eliciting their views on the acceptability, comprehensibility and usefulness of a service platform definition which was subject to qualitative analysis. Overall, respondents understood the definition and found it both acceptable and useful, subject to certain conditions. They also provided suggestions for its improvement. Our findings suggest that the service platform concept could be a useful way of aggregating mental health services as a means for presenting priority setting evidence to policy makers in mental health. However, further development and testing of the concept is required.
Mohammed, Muzaffer; Aslan, Kadir
2013-01-01
We demonstrate the design and the proof-of-concept use of a new, circular poly(methyl methacrylate)-based bioassay platform (PMMA platform), which affords for the rapid processing of 16 samples at once. The circular PMMA platform (5 cm in diameter) was coated with a silver nanoparticle film to accelerate the bioassay steps by microwave heating. A model colorimetric bioassay for biotinylated albumin (using streptavidin-labeled horse radish peroxidase) was performed on the PMMA platform coated with and without silver nanoparticles (a control experiment), and at room temperature and using microwave heating. It was shown that the simulated temperature profile of the PMMA platform during microwave heating were comparable to the real-time temperature profile during actual microwave heating of the constructed PMMA platform in a commercial microwave oven. The model colorimetric bioassay for biotinylated albumin was successfully completed in ~2 min (total assay time) using microwave heating, as compared to 90 min at room temperature (total assay time), which indicates a ~45-fold decrease in assay time. Our PMMA platform design afforded for significant reduction in non-specific interactions and low background signal as compared to non-silvered PMMA surfaces when employed in a microwave-accelerated bioassay carried out in a conventional microwave cavity.
Walther, Désirée; Steinmann, Olivia; Schaefer, Johanna; Wagner, Thomas O F; Storf, Holger
2018-01-01
Due to low prevalence of rare diseases and lack of expertise, patients suffering rare diseases are challenged with finding experts that are specialized and experienced in treating their conditions and get qualified answers. To address this issue, the approach of an interactive platform was made, which should allow affected patients or physicians the possibility to ask experts their specific questions to gather and improve their knowledge about their condition. This paper introduces the pan-European Internet platform EXABO, an Expert Advisory Board, which is developed within the framework of the European Reference Network for rare respiratory diseases (ERN-LUNG). The purpose of establishing this platform is initially dedicated to rare respiratory diseases in whole Europe, whilst the set-up is however, planned to be a generic tool for additional diseases or groups of diseases. This paper gives an overview of the concept and planning of the EXABO platform and shows how the platform is to be implemented.
Evaluation of composite wear with a new multi-mode oral wear simulator.
Condon, J R; Ferracane, J L
1996-07-01
The goals of this study were to develop a machine which simultaneously produces wear through the two main oral wear mechanisms of abrasion and attrition by the action of an enamel antagonist and to compare the results obtained for dental composites using this machine to those obtained from clinical studies and other in vitro studies. The accuracy of this new wear tester was determined by examining 11 commercial composite filling materials and 1 amalgam. Specimens were subjected to three-body abrasion and attrition wear for 50,000 cycles. Profilometry was used to quantitate wear of the composites. Linear regression analysis was used to correlate the results to those obtained from clinical studies, as well as from other in vitro wear testers. The area of enamel wear was also determined by image analysis. The SEM was used to evaluate the wear surfaces. The lowest abrasion wear was recorded for the amalgam and for the microfill and smaller-particle composites. Attrition wear was enhanced for the microfill composites and one small-particle hybrid. There was a strong correlation between the results obtained with the new wear tester and those obtained in the clinical trials cited in the literature. Wear of the enamel antagonist was the greatest for the composites with the largest particle sizes. The wear tester showed a reasonable correlation with other wear-producing machines. A new wear tester developed to evaluate and discriminate abrasion and attrition wear provided results similar to those reported in the literature for a variety of commercial composites. The new machine is capable of characterizing the behavior of a material in multiple wear modes simultaneously with one simple, realistic test.
Computational Fluid Dynamics Analysis of the Venturi Dustiness Tester
Dubey, Prahit; Ghia, Urmila; Turkevich, Leonid A.
2017-01-01
Dustiness quantifies the propensity of a finely divided solid to be aerosolized by a prescribed mechanical stimulus. Dustiness is relevant wherever powders are mixed, transferred or handled, and is important in the control of hazardous exposures and the prevention of dust explosions and product loss. Limited quantities of active pharmaceutical powders available for testing led to the development (at University of North Carolina) of a Venturi-driven dustiness tester. The powder is turbulently injected at high speed (Re ~ 2 × 104) into a glass chamber; the aerosol is then gently sampled (Re ~ 2 × 103) through two filters located at the top of the chamber; the dustiness index is the ratio of sampled to injected mass of powder. Injection is activated by suction at an Extraction Port at the top of the chamber; loss of powder during injection compromises the sampled dustiness. The present work analyzes the flow inside the Venturi Dustiness Tester, using an Unsteady Reynolds-Averaged Navier-Stokes formulation with the k-ω Shear Stress Transport turbulence model. The simulation considers single-phase flow, valid for small particles (Stokes number Stk <1). Results show that ~ 24% of fluid-tracers escape the tester before the Sampling Phase begins. Dispersion of the powder during the Injection Phase results in a uniform aerosol inside the tester, even for inhomogeneous injections, satisfying a necessary condition for the accurate evaluation of dustiness. Simulations are also performed under the conditions of reduced Extraction-Port flow; results confirm the importance of high Extraction-Port flow rate (standard operation) for uniform distribution of fluid tracers. Simulations are also performed under the conditions of delayed powder injection; results show that a uniform aerosol is still achieved provided 0.5 s elapses between powder injection and sampling. PMID:28638167
Baykal, D.; Siskey, R.S.; Haider, H.; Saikko, V.; Ahlroos, T.; Kurtz, S.M.
2013-01-01
The introduction of numerous formulations of Ultra-high molecular weight polyethylene (UHMWPE), which is widely used as a bearing material in orthopedic implants, necessitated screening of bearing couples to identify promising iterations for expensive joint simulations. Pin-on-disk (POD) testers capable of multidirectional sliding can correctly rank formulations of UHMWPE with respect to their predictive in vivo wear behavior. However, there are still uncertainties regarding POD test parameters for facilitating clinically relevant wear mechanisms of UHMWPE. Studies on the development of POD testing were briefly summarized. We systematically reviewed wear rate data of UHMWPE generated by POD testers. To determine if POD testing was capable of correctly ranking bearings and if test parameters outlined in ASTM F732 enabled differentiation between wear behavior of various formulations, mean wear rates of non-irradiated, conventional (25–50 kGy) and highly crosslinked (≥90 kGy) UHMWPE were grouped and compared. The mean wear rates of non-irradiated, conventional and highly crosslinked UHMWPEs were 7.03, 5.39 and 0.67 mm3/MC. Based on studies that complied with the guidelines of ASTM F732, the mean wear rates of non-irradiated, conventional and highly crosslinked UHMWPEs were 0.32, 0.21 and 0.04 mm3/km, respectively. In both sets of results, the mean wear rate of highly crosslinked UHMPWE was smaller than both conventional and non-irradiated UHMWPEs (p<0.05). Thus, POD testers can compare highly crosslinked and conventional UHMWPEs despite different test parameters. Narrowing the allowable range for standardized test parameters could improve sensitivity of multi-axial testers in correctly ranking materials. PMID:23831149
White balance tester with color sensor for industrial applications
NASA Astrophysics Data System (ADS)
Chen, Jiasheng; Zhu, XiaoSong
1996-12-01
The white balance tester is an instrument that adjusts the white balance for color TVs, monitors, and PC displays. We have designed a new white balance tester for use directly at the production line. It picks up the R (Red), G (Green), and B (Blue) signals for the screen using color sensors, compares the signals with the data previously stored in the internal memory, displays their differences with LED bars in the compare mode or displays x y Y, u v Y, JND (just noticeable difference) as well as correlated color temperature in the numerical mode. A built-in TV signal generator sets the luminance of the adjusting screen to the brightness of the reference white screen automatically. A 16-bit single chip microcomputer processes the measured values and controls the output levels of the TV signal generator.
Mission specification for three generic mission classes
NASA Technical Reports Server (NTRS)
1979-01-01
Mission specifications for three generic mission classes are generated to provide a baseline for definition and analysis of data acquisition platform system concepts. The mission specifications define compatible groupings of sensors that satisfy specific earth resources and environmental mission objectives. The driving force behind the definition of sensor groupings is mission need; platform and space transportation system constraints are of secondary importance. The three generic mission classes are: (1) low earth orbit sun-synchronous; (2) geosynchronous; and (3) non-sun-synchronous, nongeosynchronous. These missions are chosen to provide a variety of sensor complements and implementation concepts. Each mission specification relates mission categories, mission objectives, measured parameters, and candidate sensors to orbits and coverage, operations compatibility, and platform fleet size.
Evaluation of bearing configurations using the single bearing tester in liquid nitrogen
NASA Technical Reports Server (NTRS)
Jett, T.; Hall, P.; Thom, R.
1991-01-01
Various bearing configurations were tested using the Marshall Space Flight Center single bearing tester with LN2 as the cryogenic coolant. The baseline was one Rocketdyne phase one high pressure oxidizer turbopump (HPOTP) pump end 45-mm bore bearing. The bearing configurations that were tested included a Salox/M cage configuration, a silicon nitride ball configuration, an elongated cage configuration, and a Bray 601 grease configuration.
Capabilities in Context: Evaluating the Net-Centric Enterprise
2009-03-01
with an intuitive keyword search using the enterprise’s federated search capability. Service accessibility. Testers will ensure that local service has...search using the enterprise’s federated search capability. Data accessibility. Testers will ensure that Feder- ated Search results provide active link...user may request access to the data, and be available within ‘‘2 clicks’’ from the active link provided by Federated Search . Data understandability
Evans, Kerrie; Horan, Sean A; Neal, Robert J; Barrett, Rod S; Mills, Peter M
2012-06-01
Field-based methods of evaluating three-dimensional (3D) swing kinematics offer coaches and researchers the opportunity to assess golfers in context-specific environments. The purpose of this study was to establish the inter-trial, between-tester, between-location, and between-day repeatability of thorax and pelvis kinematics during the downswing using an electromagnetic motion capture system. Two experienced testers measured swing kinematics in 20 golfers (handicap < or =14 strokes) on consecutive days in an indoor and outdoor location. Participants performed five swings with each of two clubs (five-iron and driver) at each test condition. Repeatability of 3D kinematic data was evaluated by computing the coefficient of multiple determination (CMD) and the systematic error (SE). With the exception of pelvis forward bend for between-day and between-tester conditions, CMDs exceeded 0.854 for all variables, indicating high levels of overall waveform repeatability across conditions. When repeatability was compared across conditions using MANOVA, the lowest CMDs and highest SEs were found for the between-tester and between-day conditions. The highest CMDs were for the inter-trial and between-location conditions. The absence of significant differences in CMDs between these two conditions supports this method of analysing pelvis and thorax kinematics in different environmental settings without unduly affecting repeatability.
The design and analysis of single flank transmission error tester for loaded gears
NASA Technical Reports Server (NTRS)
Bassett, Duane E.; Houser, Donald R.
1987-01-01
To strengthen the understanding of gear transmission error and to verify mathematical models which predict them, a test stand that will measure the transmission error of gear pairs under design loads has been investigated. While most transmission error testers have been used to test gear pairs under unloaded conditions, the goal of this report was to design and perform dynamic analysis of a unique tester with the capability of measuring the transmission error of gears under load. This test stand will have the capability to continuously load a gear pair at torques up to 16,000 in-lb at shaft speeds from 0 to 5 rpm. Error measurement will be accomplished with high resolution optical encoders and the accompanying signal processing unit from an existing unloaded transmission error tester. Input power to the test gear box will be supplied by a dc torque motor while the load will be applied with a similar torque motor. A dual input, dual output control system will regulate the speed and torque of the system. This control system's accuracy and dynamic response were analyzed and it was determined that proportional plus derivative speed control is needed in order to provide the precisely constant torque necessary for error-free measurement.
The Mobile Aircraft Maintenance Office Concept from a Wide Area Perspective
2003-03-01
significant improvements in wireless network data rates, and enhanced mobile application platforms offers an opportunity to effectively integrate m...hardware, and mobile application platforms housing the necessary middleware software comprise the mobile landscape. The m-business network...devices. Lastly, an investigation into mobile application platforms will reveal the middleware functionality required to successfully extend suitable e
Jongstra, Susan; Beishuizen, Cathrien; Andrieu, Sandrine; Barbera, Mariagnese; van Dorp, Matthijs; van de Groep, Bram; Guillemont, Juliette; Mangialasche, Francesca; van Middelaar, Tessa; Moll van Charante, Eric; Soininen, Hilkka; Kivipelto, Miia; Richard, Edo
2017-02-01
A myriad of Web-based applications on self-management have been developed, but few focus on older people. In the face of global aging, older people form an important target population for cardiovascular prevention. This article describes the full development of an interactive Internet platform for older people, which was designed for the Healthy Ageing Through Internet Counselling in the Elderly (HATICE) study. We provide recommendations to design senior-friendly Web-based applications for a new approach to multicomponent cardiovascular prevention. The development of the platform followed five phases: (1) conceptual framework; (2) platform concept and functional design; (3) platform building (software and content); (4) testing and pilot study; and (5) final product. We performed a meta-analysis, reviewed guidelines for cardiovascular diseases, and consulted end users, experts, and software developers to create the platform concept and content. The software was built in iterative cycles. In the pilot study, 41 people aged ≥65 years used the platform for 8 weeks. Participants used the interactive features of the platform and appreciated the coach support. During all phases adjustments were made to incorporate all improvements from the previous phases. The final platform is a personal, secured, and interactive platform supported by a coach. When carefully designed, an interactive Internet platform is acceptable and feasible for use by older people with basic computer skills. To improve acceptability by older people, we recommend involving the end users in the process of development, to personalize the platform and to combine the application with human support. The interactive HATICE platform will be tested for efficacy in a multinational randomized controlled trial (ISRCTN48151589).
NASA Technical Reports Server (NTRS)
Frederick, D. K.; Lashmet, P. K.; Sandor, G. N.; Shen, C. N.; Smith, E. V.; Yerazunis, S. W.
1973-01-01
Problems related to the design and control of a mobile planetary vehicle to implement a systematic plan for the exploration of Mars are reported. Problem areas include: vehicle configuration, control, dynamics, systems and propulsion; systems analysis, terrain modeling and path selection; and chemical analysis of specimens. These tasks are summarized: vehicle model design, mathematical model of vehicle dynamics, experimental vehicle dynamics, obstacle negotiation, electrochemical controls, remote control, collapsibility and deployment, construction of a wheel tester, wheel analysis, payload design, system design optimization, effect of design assumptions, accessory optimal design, on-board computer subsystem, laser range measurement, discrete obstacle detection, obstacle detection systems, terrain modeling, path selection system simulation and evaluation, gas chromatograph/mass spectrometer system concepts, and chromatograph model evaluation and improvement.
Minatel, Lurian; Verri, Fellippo Ramos; Kudo, Guilherme Abu Halawa; de Faria Almeida, Daniel Augusto; de Souza Batista, Victor Eduardo; Lemos, Cleidiel Aparecido Araujo; Pellizzer, Eduardo Piza; Santiago, Joel Ferreira
2017-02-01
A biomechanical analysis of different types of implant connections is relevant to clinical practice because it may impact the longevity of the rehabilitation treatment. Therefore, the objective of this study is to evaluate the Morse taper connections and the stress distribution of structures associated with the platform switching (PSW) concept. It will do this by obtaining data on the biomechanical behavior of the main structure in relation to the dental implant using the 3-dimensional finite element methodology. Four models were simulated (with each containing a single prosthesis over the implant) in the molar region, with the following specifications: M1 and M2 is an external hexagonal implant on a regular platform; M3 is an external hexagonal implant using PSW concept; and M4 is a Morse taper implant. The modeling process involved the use of images from InVesalius CT (computed tomography) processing software, which were refined using Rhinoceros 4.0 and SolidWorks 2011 CAD software. The models were then exported into the finite element program (FEMAP 11.0) to configure the meshes. The models were processed using NeiNastram software. The main results are that M1 (regular diameter 4mm) had the highest stress concentration area and highest microstrain concentration for bone tissue, dental implants, and the retaining screw (P<0.05). Using the PSW concept increases the area of the stress concentrations in the retaining screw (P<0.05) more than in the regular platform implant. It was concluded that the increase in diameter is beneficial for stress distribution and that the PSW concept had higher stress concentrations in the retaining screw and the crown compared to the regular platform implant. Copyright © 2016 Elsevier B.V. All rights reserved.
Assessing the Potential of Stratospheric Balloons for Planetary Science
NASA Technical Reports Server (NTRS)
Kremic, Tibor; Hibbitts, Karl; Young, Eliot; Landis, Robert; Noll, Keith; Baines, Kevin
2013-01-01
Recent developments in high altitude balloon platform capabilities, specifically long duration flights in excess of 50 days at over 100,000 ft and precision pointing with performance at the arc sec level or better have raised the question whether this platform can be utilized for high-value planetary science observations. In January of 2012 a workshop was held at NASA Glenn Research Center in Cleveland, Ohio to explore what planetary science can be achieved utilizing such a platform. Over 40 science concepts were identified by the scientists and engineers attending the workshop. Those ideas were captured and then posted to a public website for all interested planetary scientists to review and give their comments. The results of the workshop, and subsequent community review, have demonstrated that this platform appears to have potential for high-value science at very competitive costs. Given these positive results, the assessment process was extended to include 1) examining, in more detail, the requirements for the gondola platform and the mission scenarios 2) identifying technical challenges and 3) developing one or more platform concepts in enough fidelity to enable accurate estimating of development and mission costs. This paper provides a review of the assessment, a summary of the achievable science and the challenges to make that science a reality with this platform.
Assessing the potential of stratospheric balloons for planetary science
NASA Astrophysics Data System (ADS)
Kremic, T.; Hibbitts, K.; Young, E.; Landis, R.; Noll, K.; Baines, K.
Recent developments in high altitude balloon platform capabilities, specifically long duration flights in excess of 50 days at over 100,000 ft and precision pointing with performance at the arc sec level or better have raised the question whether this platform can be utilized for high-value planetary science observations. In January of 2012 a workshop was held at NASA Glenn Research Center in Cleveland, Ohio to explore what planetary science can be achieved utilizing such a platform. Over 40 science concepts were identified by the scientists and engineers attending the workshop. Those ideas were captured and then posted to a public website for all interested planetary scientists to review and give their comments. The results of the workshop, and subsequent community review, have demonstrated that this platform appears to have potential for high-value science at very competitive costs. Given these positive results, the assessment process was extended to include 1) examining, in more detail, the requirements for the gondola platform and the mission scenarios 2) identifying technical challenges and 3) developing one or more platform concepts in enough fidelity to enable accurate estimating of development and mission costs. This paper provides a review of the assessment, a summary of the achievable science and the challenges to make that science a reality with this platform.
1981-12-01
During 1980 and the first half of 1981, the Marshall Space Flight Center conducted studies concerned with a relatively low-cost, near-term, manned space platform to satisfy current user needs, yet capable of evolutionary growth to meet future needs. The Science and Application Manned Space Platform (SAMSP) studies were to serve as a test bed for developing scientific and operational capabilities required by later, more advanced manned platforms while accomplishing early science and operations. This concept illustrates a manned space platform.
Geostationary platform systems concepts definition study. Volume 2: Technical, book 3
NASA Technical Reports Server (NTRS)
1980-01-01
The supporting research and technology, and space demonstrations required to support the 1990s operational geostationary platforms are identified. Also the requirements on and interfaces with the Space Transportation System hardware elements supporting the geostationary platform program, including the shuttle, orbital transfer vehicles, teleoperator, etc., are investigated to provide integrated support requirements. Finally, a preliminary evaluation of the practicability and capabilities of an experimental platform from the standpoint of technology, schedule, and cost is given.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morgan, Michael J.
The Hydrogen Fracture Toughness Tester (HFTT) is a mechanical testing machine designed for conducting fracture mechanics tests on materials in high-pressure hydrogen gas. The tester is needed for evaluating the effects of hydrogen on the cracking properties of tritium reservoir materials. It consists of an Instron Model 8862 Electromechanical Test Frame; an Autoclave Engineering Pressure Vessel, an Electric Potential Drop Crack Length Measurement System, associated computer control and data acquisition systems, and a high-pressure hydrogen gas manifold and handling system.
Tester Detects Steady-Short Or Intermittent-Open Circuits
NASA Technical Reports Server (NTRS)
Anderson, Bobby L.
1990-01-01
Momentary open circuits or steady short circuits trigger buzzer. Simple, portable, lightweight testing circuit sounds long-duration alarm when it detects steady short circuit or momentary open circuit in coaxial cable or other two-conductor transmission line. Tester sensitive to discontinuities lasting 10 microseconds or longer. Used extensively for detecting intermittent open shorts in accelerometer and extensometer cables. Also used as ordinary buzzer-type continuity checker to detect steady short or open circuits.
Review of LOX Bearing and Seal Materials Tester (BSMT) radial load system
NASA Technical Reports Server (NTRS)
Dufrane, K. F.; Kannel, J. W.
1984-01-01
Problems concerning the bearings in the high pressure oxygen turbopumps (HPOTP) were investigated. The tasks involved: failure analyses, bearing dynamics calculations, lubrication studies, wear studies, and analyses of thermal transients. The radial load system on MSFC's bearing and seal tester used to study components for the HPOTP in liquid oxygen (LOX) is analyzed and the wear behavior of AISI 440C steel with polytetrafluoroethylene (PTFE) lubrication is studied.
A Portable Sorption Tester for Nondestructive Testing of Chemical Protective Garments
1992-08-01
ö.^ TECHNICAL REPORT NATICK/TR-92/042 Ap AASL MI A PORTABLE SORPTION TESTER FOR NONDESTRUCTIVE TESTING OF CHEMICAL PROTECTIVE GARMENTS ...items. DESTRUCTION NOTICE For Classified Documents: Follow the procedures in DoD 5200.22-M, Industrial Security Manual, Section 11-19 or DoD...disclosure of contents or reconstruction of the document. REPORT DOCUMENTATION PAGE Form Approved OMB No . 0704-0188 Public ’»oor.ra Ouro«" ":> -n
Tester Independent Support Software System (TISSS)
1991-08-01
AD-A240 668 RL-TR-91-163 Final Technical Report August 1991 TESTER INDEPENDENT SUPPORT SOFTWARE SYSTEM (TISSS) Harris Corporation Dr. Robert Rolfe...Laboratory Air Force Systems Command Griffiss Air Force Base, NY 13441-5700 9_1 9 17 o15 This report has been reviewed by the Rome Laboratory Public...will assist us in maintaining a current mailing list. Do not return copies of this report unless contractual obligations or notices on a specific
Non-Intrusive Impedance-Based Cable Tester
NASA Technical Reports Server (NTRS)
Medelius, Pedro J. (Inventor); Simpson, Howard J. (Inventor)
1999-01-01
A non-intrusive electrical cable tester determines the nature and location of a discontinuity in a cable through application of an oscillating signal to one end of the cable. The frequency of the oscillating signal is varied in increments until a minimum, close to zero voltage is measured at a signal injection point which is indicative of a minimum impedance at that point. The frequency of the test signal at which the minimum impedance occurs is then employed to determine the distance to the discontinuity by employing a formula which relates this distance to the signal frequency and the velocity factor of the cable. A numerically controlled oscillator is provided to generate the oscillating signal, and a microcontroller automatically controls operation of the cable tester to make the desired measurements and display the results. The device is contained in a portable housing which may be hand held to facilitate convenient use of the device in difficult to access locations.
The I-V Measurement System for Solar Cells Based on MCU
NASA Astrophysics Data System (ADS)
Fengxiang, Chen; Yu, Ai; Jiafu, Wang; Lisheng, Wang
2011-02-01
In this paper, an I-V measurement system for solar cells based on Single-chip Microcomputer (MCU) is presented. According to the test principles of solar cells, this measurement system mainly comprises of two parts—data collecting, data processing and displaying. The MCU mainly used as to acquire data, then the collecting results is sent to the computer by serial port. The I-V measurement results of our test system are shown in the human-computer interaction interface based on our hardware circuit. By comparing the test results of our I-V tester and the results of other commercial I-V tester, we found errors for most parameters are less than 5%, which shows our I-V test result is reliable. Because the MCU can be applied in many fields, this I-V measurement system offers a simple prototype for portable I-V tester for solar cells.
Research on Microstructure and Properties of Welded Joint of High Strength Steel
NASA Astrophysics Data System (ADS)
Zhu, Pengxiao; Li, Yi; Chen, Bo; Ma, Xuejiao; Zhang, Dongya; Tang, Cai
2018-01-01
BS960 steel plates were welded by Laser-MAG and MAG. The microstructure and properties of the welded joints were investigated by optical microscope, micro-hardness tester, universal tensile testing machine, impact tester, scanning electron microscope (SEM) and fatigue tester. By a series of experiments, the following results were obtained: The grain size of the coarse grain zone with Laser-MAG welded joint is 20μm, and that with MAG welded joint is about 32μm, both of the fine grain region are composed of fine lath martensite and granular bainite; the width of the heat affected region with Laser-MAG is lower than that with MAG. The strength and impact energy of welded joints with Laser-MAG is higher than that with MAG. The conditioned fatigue limit of welded joint with Laser-MAG is 280MPa; however, the conditioned fatigue limit of welded joint with MAG is 250MPa.
An Overview of Advanced Concepts for Launch
2012-02-09
Loads, System. --- Space Platforms Unfeasible. --- Space Elevator Materials, O, µmeteoroids, weather, vibrations.. Asteroid Mining Breakthrough...Unfeasible. --- Space Elevator Materials, O, µmeteoroids, weather, vibrations.. Asteroid Mining Breakthrough Physics No known feasible concepts
IT behind a platform for Translational Cancer Research - concept and objectives.
Steffens, Michael; Husmann, Gabriele; Koca, Mithat; Lablans, Martin; Komor, Martina; Zeissig, Sylke; Emrich, Katharina; Brandts, Christian; Serve, Hubert; Blettner, Maria; Uckert, Frank
2012-01-01
The German Consortium for Translational Cancer Research (DKTK) and the Rhine-Main Translational Cancer Research Network (RM-TCRN) are designed to exploit large population cohorts of cancer patients for the purpose of bio-banking, clinical trials, and clinical cancer registration. Hence, the success of these platforms is heavily dependent on the close interlinking of clinical data from cancer patients, information from study registries, and data from bio-banking systems of different laboratories and scientific institutions. This article referring to the poster discusses the main challenges of the platforms from an information technology point of view, legal and data security issues, and outlines an integrative IT-concept concerning a decentralized, distributed search approach where data management and search is in compliance with existing legislative rules.
Han, Jun-hua; Li, Yan-ping; Men, Jian-hua; Yu, Wen-tao; Yang, Yue-xin
2009-12-01
To investigate the dietary phytosterol intake of elderly women in three different cities of China, and to compare the main dietary sources, so that to discuss the relationship of dietary phytosterol intake and serum lipids. Based on the dietary pattern, women more than 50 years old from Beijing, Hefei and Urumchi were chosen as testers, 80 - 100 people for each city respectively. The dietary survey was done by continues 24 hours review of two days, the plant food were collected and the phytosterol content (include beta-sitosterol, campesterol, stigmasterol, sitostanol) were analyzed by GC methods, the total phytosterols content were calculated. The dietary phytosterol intake were calculated and serum lipids were also analyzed in all the testers. Testers from Beijing, Hefei and Urumchi were 100, 101 and 84 respectively. The average dietary phytosterol intake of people in Beijing and Hefei were 340.3 mg/d and 313.5 mg/d, the main sources were plant oil and cereals, while the average dietary phytosterol intake of people in Urumchi were 550.4 mg/d, higher than the other two cities (t values were 9.369, 10.420, respectively, both P values < 0.01), the main source in Urumchi was cereal (provide 53.1% of the total phytosterol intake). The laboratory results showed, testers in Urumchi had significantly lower serum TC content ((4.04 +/- 0.78) mmol/L) than that in Beijing ((4.89 +/- 0.91) mmol/L) and Hefei ((4.71 +/- 0.83) mmol/L) (t value were 6.766 and 5.401 respectively, both P values < 0.01); serum TG content in Urumchi((1.01 +/- 0.48) mmol/L) was also lower than that in Beijing ((1.31 +/- 0.53) mmol/L) and Hefei ((1.66 +/- 0.75) mmol/L) (t values were 3.343 and 7.293 respectively, both P values < 0.01); the serum glucose is also lower in testers in Urumchi ((5.02 +/- 2.18) mmol/L) compared with testers in Beijing ((5.69 +/- 1.53) mmol/L, t = 2.561, P < 0.05) and Hefei ((5.78 +/- 1.53) mmol/L, t = 2.934, P < 0.01). Different dietary pattern result in significantly different dietary phytosterol intake in elder women in three cities, higher, phytosterol intake seemed to contribute to lower serum lipids.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bech, H.; Haugsen, P.B.
The Norwegian Oil Company, Saga Petroleum a.s., is operator on two promising deep water blocks in the Norwegian sector of the North Sea. As a result, the company has introduced a new platform concept designed specifically for hostile and deep water areas. The platform idea is the result of a systematic innovation procedure. The first step was to analyze and describe the functions of the different structural elements on a general basis. Next was to analyze how these elements contributed to the total concept. The final development stage was to create a new solution. The resulting (hybrid platform design conceptmore » appears to offer a number of inherent deck layout and towout deck weight advantages). The concrete substructure is a lower unit consisting of a foundation with concrete skirts that will penetrate the soft soil in the seabed and a high concrete caisson extending up from the foundation, which is made up of seven cells with varying concrete thicknesses, terminating in domes. The upper steel platform section is a lattice-type jacket structure. There is a separate column for internal personnel access between the platform deck and the concrete caisson.« less
ERIC Educational Resources Information Center
Ottersten, Eugenia Kazamaki; Steedman, Hilary; Schneeberger, Arthur; Carneiro, Roberto
2000-01-01
Three articles debate the findings of a study: "Low-Skilled People on the European Labor Market: Towards a Minimum Learning Platform?" (Ottersen, Steedman); "The Concept of a Minimum Learning Platform Educational Contents and Methods for Improving the Low-Skilled" (Schneeberger); and "Achieving a Minimum Learning Platform…
NASA Technical Reports Server (NTRS)
1980-01-01
The results of the Large Space Systems Technology special emphasis task are presented. The task was an analysis of structural requirements deriving from the initial Phase A Operational Geostationary Platform study.
A Tester for Carbon Nanotube Mode Lockers
NASA Astrophysics Data System (ADS)
Song, Yong-Won; Yamashita, Shinji
2007-05-01
We propose and demonstrate a tester for laser pulsating operation of carbon nanotubes employing a circulator with the extra degree of freedom of the second port to access diversified nanotube samples. The nanotubes are deposited onto the end facet of a dummy optical fiber by spray method that guarantees simple sample loading along with the minimized perturbation of optimized laser cavity condition. Resultant optical spectra, autocorrelation traces and pulse train of the laser outputs with qualified samples are presented.
An automated digital data collection and analysis system for the Charpy Impact Tester
NASA Technical Reports Server (NTRS)
Kohne, Glenn S.; Spiegel, F. Xavier
1994-01-01
The standard Charpy Impact Tester has been modified by the addition of a system of hardware and software to improve the accuracy and consistency of measurements made during specimen fracturing experiments. An optical disc, light source, and detector generate signals that indicate the pendulum position as a function of time. These signals are used by a computer to calculate the velocity and kinetic energy of the pendulum as a function of its position.
Endurance cycling results in extreme environments
NASA Technical Reports Server (NTRS)
Guertin, S. M.; Nguyen, D. N.; Scheick, L. Z.
2003-01-01
A new test bed for life testing flash memories in extreme environments is introducted. the test bed is based on a state-of-the-art development board. Since space applications often desire state-of-the-art devices, such a basis seems appropriate. Comparison of this tester to other such systems, including those with data presented here in the past is made. Limitations of different testers for varying applications are discussed. Recently developed data, using this test bed is also presented.
Orbital fatigue tester for use in Skylab experiment T032
NASA Technical Reports Server (NTRS)
Sandorff, P. E.
1973-01-01
A prototype fatigue test machine is described which is suitable for use by an astronaut in conducting constant amplitude materials fatigue tests aboard a Skylab or space shuttle vehicle. The machine is comparised of a mechanical tester, which would be passed through a small (7.6-inch square) airlock to be supported in the space environment on an extendible boom, and a control console, which would provide remote control from within the space vehicle.
Inspection tester for explosives
Haas, Jeffrey S.; Simpson, Randall L.; Satcher, Joe H.
2007-11-13
An inspection tester that can be used anywhere as a primary screening tool by non-technical personnel to determine whether a surface contains explosives. It includes a body with a sample pad. First and second explosives detecting reagent holders and dispensers are operatively connected to the body and the sample pad. The first and second explosives detecting reagent holders and dispensers are positioned to deliver the explosives detecting reagents to the sample pad. A is heater operatively connected to the sample pad.
Inspection tester for explosives
Haas, Jeffrey S.; Simpson, Randall L.; Satcher, Joe H.
2010-10-05
An inspection tester that can be used anywhere as a primary screening tool by non-technical personnel to determine whether a surface contains explosives. It includes a body with a sample pad. First and second explosives detecting reagent holders and dispensers are operatively connected to the body and the sample pad. The first and second explosives detecting reagent holders and dispensers are positioned to deliver the explosives detecting reagents to the sample pad. A is heater operatively connected to the sample pad.
Glasman, Laura R.; Dickson-Gomez, Julia; Lechuga, Julia; Tarima, Sergey; Bodnar, Gloria; de Mendoza, Lorena Rivas
2016-01-01
In El Salvador, crack users are at high risk for HIV but they are not targeted by efforts to promote early HIV diagnosis. We evaluated the promise of peer-referral chains with incentives to increase HIV testing and identify undiagnosed HIV infections among networks of crack users in San Salvador. For 14 months, we offered HIV testing in communities with a high prevalence of crack use. For the following 14 months, we promoted chains in which crack users from these communities referred their peers to HIV testing and received a small monetary incentive. We recorded the monthly numbers of HIV testers, and their crack use, sexual risk behaviors and test results. After launching the referral chains, the monthly numbers of HIV testers increased significantly (Z = 6.90, p < .001) and decayed more slowly (Z = 5.93, p < .001), and the total number of crack-using testers increased nearly fourfold. Testers in the peer-referral period reported fewer HIV risk behaviors, but a similar percentage (~5 %) tested HIV positive in both periods. More women than men received an HIV-positive diagnosis throughout the study (χ2(1, N = 799) = 4.23, p = .040). Peer-referral chains with incentives can potentially increase HIV testing among networks of crack users while retaining a focus on high-risk individuals. PMID:26687093
Comparative testing of pulse oximeter probes.
van Oostrom, Johannes H; Melker, Richard J
2004-05-01
The testing of pulse oximeter probes is generally limited to the integrity of the electrical circuit and does not include the optical properties of the probes. Few pulse oximeter testers evaluate the accuracy of both the monitor and the probe. We designed a study to compare the accuracy of nonproprietary probes (OSS Medical) designed for use with Nellcor, Datex-Ohmeda, and Criticare pulse oximeter monitors with that of their corresponding proprietary probes by using a commercial off-the-shelf pulse oximeter tester (Index). The Index pulse oximeter tester does include testing of the optical properties of the pulse oximeter probes. The pulse oximeter tester was given a controlled input that simulated acute apnea. Desaturation curves were automatically recorded from the pulse oximeter monitors with a data-collection computer. Comparisons between equivalent proprietary and nonproprietary probes were performed. Data were analyzed by using univariate and multivariate general linear model analysis. Five OSS Medical probe models were statistically better than the equivalent proprietary probes. The remainder of the probes were statistically similar. Comparative and simulation studies can have significant advantages over human studies because they are cost-effective, evaluate equipment in a clinically relevant scenario, and pose no risk to patients, but they are limited by the realism of the simulation. We studied the performance of pulse oximeter probes in a simulated environment. Our results show significant differences between some probes that affect the accuracy of measurement.
Spörndly-Nees, Søren; Dåsberg, Brian; Nielsen, Rasmus Oestergaard; Boesen, Morten Ilum
2011-01-01
Background: Lower limb injuries are a large problem in athletes. However, there is a paucity of knowledge on the relationship between alignment of the medial longitudinal arch (MLA) of the foot and development of such injuries. A reliable and valid test to quantify foot type is needed to be able to investigate the relationship between arch type and injury likelihood. Feiss Line is a valid clinical measure of the MLA. However, no study has investigated the reliability of the test. Objectives: The purpose was to describe a modified version of the Feiss Line test and to determine the intra- and inter-tester reliability of this new foot alignment test. To emphasize the purpose of the modified test, the authors have named it The Navicular Position Test. Methods: Intra- and inter-tester reliability were evaluated of The Navicular Position Test with the use of ICC (interclass correlation coefficient) and Bland-Altman limits of agreement on 43 healthy, young, subjects. Results: Inter-tester mean difference -0.35 degrees [–1.32; 0.62] p = 0.47. Bland-Altman limits of agreement –6.55 to 5.85 degrees, ICC = 0.94. Intra-tester mean difference 0.47 degrees [–0.57; 1.50] p = 0.37. Bland-Altman limits of agreement –6.15 to 7.08 degrees, ICC = 0.91. Discussion: The present data support The Navicular Position Test as a reliable test of the navicular bone position during rest and loading measured in a simple test set-up. Conclusion: The Navicular Position Test was shown to have a high intraday-, intra- and inter-tester reliability. When cut off values to categorize the MLA into planus, rectus, or cavus feet, has been determined and presented, the test could be used in prospective observational studies investigating the role of the arch type on the development of various lower limb injuries. PMID:21904698
Leng, Yumin; Qian, Sihua; Wang, Yuhui; Lu, Cheng; Ji, Xiaoxu; Lu, Zhiwen; Lin, Hengwei
2016-01-01
Multidimensional sensing offers advantages in accuracy, diversity and capability for the simultaneous detection and discrimination of multiple analytes, however, the previous reports usually require complicated synthesis/fabrication process and/or need a variety of techniques (or instruments) to acquire signals. Therefore, to take full advantages of this concept, simple designs are highly desirable. Herein, a novel concept is conceived to construct multidimensional sensing platforms based on a single indicator that has capability of showing diverse color/fluorescence responses with the addition of different analytes. Through extracting hidden information from these responses, such as red, green and blue (RGB) alterations, a triple-channel-based multidimensional sensing platform could consequently be fabricated, and the RGB alterations are further applicable to standard statistical methods. As a proof-of-concept study, a triple-channel sensing platform is fabricated solely using dithizone with assistance of cetyltrimethylammonium bromide (CTAB) for hyperchromicity and sensitization, which demonstrates superior capabilities in detection and identification of ten common heavy metal ions at their standard concentrations of wastewater-discharge of China. Moreover, this sensing platform exhibits promising applications in semi-quantitative and even quantitative analysis individuals of these heavy metal ions with high sensitivity as well. Finally, density functional theory calculations are performed to reveal the foundations for this analysis. PMID:27146105
NASA Technical Reports Server (NTRS)
Ollendorf, S.; Fowle, A.; Almgren, D.
1981-01-01
A system utilizing a pumped, two-phase single component working fluid for heat exchange and transport services necessary to meet the temperature control requirements of typical orbiting instrument payloads on space platforms is described. The design characteristics of the system is presented, together with a presentation of a laboratory apparatus for demonstration of proof of concept. Results indicate that the pumped two-phase design concept can meet a wide range of thermal performance requirements with the only penalty being the requirement for a small liquid pump.
Enhanced Master Controller Unit Tester
NASA Technical Reports Server (NTRS)
Benson, Patricia; Johnson, Yvette; Johnson, Brian; Williams, Philip; Burton, Geoffrey; McCoy, Anthony
2007-01-01
The Enhanced Master Controller Unit Tester (EMUT) software is a tool for development and testing of software for a master controller (MC) flight computer. The primary function of the EMUT software is to simulate interfaces between the MC computer and external analog and digital circuitry (including other computers) in a rack of equipment to be used in scientific experiments. The simulations span the range of nominal, off-nominal, and erroneous operational conditions, enabling the testing of MC software before all the equipment becomes available.
Helium Bottle Pressure Measurement by Portable Ultrasonic Technique
1989-02-07
revision extends the study to include EMI testing, and -develorynent of g Rrotgtype tester . The Contractor shall: 1. Perform EMI test of ultrasonic eq...amp/1 watt power ap- plied to the bridgerires. The tester pulse of 250 volts for 100 ns at 1500 pps has an average value of 250v x 100ns x 1500pps...34 connector. Mount transducer in fixture and connect transducer to cable microdot connector. 5. Pulse-Echo transit time measurement: Assure that the
2016-06-25
The equipment used in this procedure includes: Ann Arbor distortion tester with 50-line grating reticule, IQeye 720 digital video camera with 12...and import them into MATLAB. In order to digitally capture images of the distortion in an optical sample, an IQeye 720 video camera with a 12... video camera and Ann Arbor distortion tester. Figure 8. Computer interface for capturing images seen by IQeye 720 camera. Once an image was
Small-Bolt Torque-Tension Tester
NASA Technical Reports Server (NTRS)
Posey, Alan J.
2009-01-01
The device described here measures the torque-tension relationship for fasteners as small as #0. The small-bolt tester consists of a plate of high-strength steel into which three miniature load cells are recessed. The depth of the recess is sized so that the three load cells can be shimmed, the optimum height depending upon the test hardware. The three miniature load cells are arranged in an equilateral triangular configuration with the test bolt aligned with the centroid of the three. This is a kinematic arrangement.
ABA-Cloud: support for collaborative breath research
Elsayed, Ibrahim; Ludescher, Thomas; King, Julian; Ager, Clemens; Trosin, Michael; Senocak, Uygar; Brezany, Peter; Feilhauer, Thomas; Amann, Anton
2016-01-01
This paper introduces the advanced breath analysis (ABA) platform, an innovative scientific research platform for the entire breath research domain. Within the ABA project, we are investigating novel data management concepts and semantic web technologies to document breath analysis studies for the long run as well as to enable their full automatic reproducibility. We propose several concept taxonomies (a hierarchical order of terms from a glossary of terms), which can be seen as a first step toward the definition of conceptualized terms commonly used by the international community of breath researchers. They build the basis for the development of an ontology (a concept from computer science used for communication between machines and/or humans and representation and reuse of knowledge) dedicated to breath research. PMID:23619467
ABA-Cloud: support for collaborative breath research.
Elsayed, Ibrahim; Ludescher, Thomas; King, Julian; Ager, Clemens; Trosin, Michael; Senocak, Uygar; Brezany, Peter; Feilhauer, Thomas; Amann, Anton
2013-06-01
This paper introduces the advanced breath analysis (ABA) platform, an innovative scientific research platform for the entire breath research domain. Within the ABA project, we are investigating novel data management concepts and semantic web technologies to document breath analysis studies for the long run as well as to enable their full automatic reproducibility. We propose several concept taxonomies (a hierarchical order of terms from a glossary of terms), which can be seen as a first step toward the definition of conceptualized terms commonly used by the international community of breath researchers. They build the basis for the development of an ontology (a concept from computer science used for communication between machines and/or humans and representation and reuse of knowledge) dedicated to breath research.
NASA Technical Reports Server (NTRS)
Szuszczewicz, Edward P.
1986-01-01
Large, permanently-manned space platforms can provide exciting opportunities for discoveries in basic plasma and geoplasma sciences. The potential for these discoveries will depend very critically on the properties of the platform, its subsystems, and their abilities to fulfill a spectrum of scientific requirements. With this in mind, the planning of space station research initiatives and the development of attendant platform engineering should allow for the identification of critical science and technology issues that must be clarified far in advance of space station program implementation. An attempt is made to contribute to that process, with a perspective that looks to the development of the space station as a permanently-manned Spaceborne Ionospheric Weather Station. The development of this concept requires a synergism of science and technology which leads to several critical design issues. To explore the identification of these issues, the development of the concept of an Ionospheric Weather Station will necessarily touch upon a number of diverse areas. These areas are discussed.
NASA Astrophysics Data System (ADS)
Zaleski, S.; Page, H. M.; Miller, R. J.; Doheny, B.; Dugan, J. E.; Schroeder, D. M.
2016-02-01
Twenty-seven oil and gas platforms are arrayed offshore California from north of Point Conception south to San Pedro Bay (a coastline distance of >300 km). To test the hypothesis that variability in the structure of sessile invertebrate communities on the platforms is associated with regional differences in sea surface temperature, we sampled space-holding invertebrate taxa photographically on 23 platforms and compared the composition and cover of invertebrates among and within regions using multivariate analyses. To explore temporal variability in invertebrate assemblages, we also compared the cover and composition of invertebrates on a subset of platforms in the Santa Barbara Channel (SBC) where data were collected over ten years previously. The composition of invertebrate assemblages differed significantly among regions, and was driven by variation in the relative abundance of certain anemone, bryozoan, tubiferous annelid, sponge, and bivalve taxa. The presence of non-native bryozoan and anemone taxa on some platforms in the south (San Pedro Bay) and southeast SBC contributed to the distinction of these assemblages from the others. Comparison of survey data on the subset of platforms in the SBC surveyed over ten years apart revealed little change in the cover of major space-holding taxa (e.g., anemones Metridium, Corynactis) across platforms, although there was an increase in cover of the non-native bryozoan Watersipora subtorquata between surveys. The existence of geographical patterns in the composition of platform invertebrate assemblages suggests that these assemblages may be useful as barometers of short and longer-term environmental change. For biogeographic transition zones, such as the SBC, monitoring of platform invertebrate assemblages could permit an evaluation of the concept that these zones are particularly susceptible to shifts in the composition of marine species driven by ocean climate.
MSIX - A general and user-friendly platform for RAM analysis
NASA Astrophysics Data System (ADS)
Pan, Z. J.; Blemel, Peter
The authors present a CAD (computer-aided design) platform supporting RAM (reliability, availability, and maintainability) analysis with efficient system description and alternative evaluation. The design concepts, implementation techniques, and application results are described. This platform is user-friendly because of its graphic environment, drawing facilities, object orientation, self-tutoring, and access to the operating system. The programs' independency and portability make them generally applicable to various analysis tasks.
Conceptual design study. Science and Applications Space Platform (SASP). Final briefing
NASA Technical Reports Server (NTRS)
1980-01-01
The modularity, shape, and size of the recommended platform concept offers a low investment, early option to demonstrate the system; flexibility to conservative growth; adaptability to great variety of multi or dedicated payload groups; and good dispersion and viewing freedom for payloads. Platform configuration effectively supports 80 to 85% of the NASA/OSS and OSTA payloads. The subsystem approaches recommended are based on cost effective distribution of functions.
Innovation through developing consumers communities. Part II: Digitalizing the innovation processes
NASA Astrophysics Data System (ADS)
Avasilcai, S.; Galateanu (Avram, E.
2015-11-01
The current research recognises the concept of innovation as the main driver for organisational growth and profitability. The companies seek to develop new ways to engage consumers and customers into co - creation value through the product design, development and distribution processes. However the main concern is manifested for new and creative ways of customization products based on consumers’ requirements and needs. Thus the need for innovative virtual instruments arose as the demand from social communities for personalised products or services increased. Basically companies should develop own innovative platforms, where consumers can participate, with ideas, concepts or other relevant contributions, and interact with designers or engineers for product development. This paper aims to present the most important features of platform development within BMW Group as a concept and as innovative instrument. From this point of view it is important to enhance past experiences of the company in the field of co - creation projects. There will be highlighted the dual consumers’ character as co - creator and co - evaluator based on their involvement in the proposed and developed projects and platform structure. The significant impact on platform functioning it has the diversity of company's concerns for Research & Development and innovation activities. From this point of view there will be assessed the platform structure, the main proposed themes and the evaluation process. The main outcome is to highlight the significance of platform development as innovative tool for consumers’ communities’ enhancement. Based on the analysis of “BMW Co-Creation Lab”, there will be revealed the main consumers concerns in terms of safety, comfort and appearance of the products. Thus it is important to understand the evaluation process of gathered ideas and intellectual property policy. The importance of platform development and implementation will be highlighted by company's results in terms of Research & Development investments and future projects which will be proposed, assessed and implemented by BMW Group in order to show the responsibility for their products and consumers.
NASA Technical Reports Server (NTRS)
Frederick, D. K.; Lashmet, P. K.; Sandor, G. N.; Shen, C. N.; Smith, E. J.; Yerazunis, S. W.
1972-01-01
The problems related to the design and control of a mobile planetary vehicle to implement a systematic plan for the exploration of Mars were investigated. Problem areas receiving attention include: vehicle configuration, control, dynamics, systems and propulsion; systems analysis; navigation, terrain modeling and path selection; and chemical analysis of specimens. The following specific tasks were studied: vehicle model design, mathematical modeling of dynamic vehicle, experimental vehicle dynamics, obstacle negotiation, electromechanical controls, collapsibility and deployment, construction of a wheel tester, wheel analysis, payload design, system design optimization, effect of design assumptions, accessory optimal design, on-board computer subsystem, laser range measurement, discrete obstacle detection, obstacle detection systems, terrain modeling, path selection system simulation and evaluation, gas chromatograph/mass spectrometer system concepts, chromatograph model evaluation and improvement and transport parameter evaluation.
NASA Technical Reports Server (NTRS)
Frederick, D. K.; Lashmet, P. K.; Sandor, G. N.; Shen, C. N.; Smith, E. J.; Yerazunis, S. W.
1972-01-01
Investigation of problems related to the design and control of a mobile planetary vehicle to implement a systematic plan for the exploration of Mars has been undertaken. Problem areas receiving attention include: vehicle configuration, control, dynamics, systems and propulsion; systems analysis; terrain modeling and path selection; and chemical analysis of specimens. The following specific tasks have been under study: vehicle model design, mathematical modeling of a dynamic vehicle, experimental vehicle dynamics, obstacle negotiation, electromechanical controls, collapsibility and deployment, construction of a wheel tester, wheel analysis, payload design, system design optimization, effect of design assumptions, accessory optimal design, on-board computer sybsystem, laser range measurement, discrete obstacle detection, obstacle detection systems, terrain modeling, path selection system simulation and evaluation, gas chromatograph/mass spectrometer system concepts, chromatograph model evaluation and improvement.
Lee, Yong Yi; Meurk, Carla S.; Harris, Meredith G.; Diminic, Sandra; Scheurer, Roman W.; Whiteford, Harvey A.
2014-01-01
Ensuring that a mental health system provides ‘value for money’ requires policy makers to allocate resources to the most cost-effective interventions. Organizing cost-effective interventions into a service delivery framework will require a concept that can guide the mapping of evidence regarding disorder-level interventions to aggregations of services that are meaningful for policy makers. The ‘service platform’ is an emerging concept that could be used to this end, however no explicit definition currently exists in the literature. The aim of this study was to develop a service platform definition that is consistent with how policy makers conceptualize the major elements of the mental health service system and to test the validity and utility of this definition through consultation with mental health policy makers. We derived a provisional definition informed by existing literature and consultation with experienced mental health researchers. Using a modified Delphi method, we obtained feedback from nine Australian policy makers. Respondents provided written answers to a questionnaire eliciting their views on the acceptability, comprehensibility and usefulness of a service platform definition which was subject to qualitative analysis. Overall, respondents understood the definition and found it both acceptable and useful, subject to certain conditions. They also provided suggestions for its improvement. Our findings suggest that the service platform concept could be a useful way of aggregating mental health services as a means for presenting priority setting evidence to policy makers in mental health. However, further development and testing of the concept is required. PMID:25431877
Rocketdyne LOX bearing tester program
NASA Technical Reports Server (NTRS)
Keba, J. E.; Beatty, R. F.
1988-01-01
The cause, or causes, for the Space Shuttle Main Engine ball wear were unknown, however, several mechanisms were suspected. Two testers were designed and built for operation in liquid oxygen to empirically gain insight into the problems and iterate solutions in a timely and cost efficient manner independent of engine testing. Schedules and test plans were developed that defined a test matrix consisting of parametric variations of loading, cooling or vapor margin, cage lubrication, material, and geometry studies. Initial test results indicated that the low pressure pump thrust bearing surface distress is a function of high axial load. Initial high pressure turbopump bearing tests produced the wear phenomenon observed in the turbopump and identified an inadequate vapor margin problem and a coolant flowrate sensitivity issue. These tests provided calibration data of analytical model predictions to give high confidence in the positive impact of future turbopump design modification for flight. Various modifications will be evaluated in these testers, since similar turbopump conditions can be produced and the benefit of the modification will be quantified in measured wear life comparisons.
[Design of the psychology tester based on ZigBee technology].
Zhong, Tianping; Tang, Liming
2012-09-01
To design a psychological state tester based on ZigBee wireless technology. Through analog circuit preprocessing, the heartbeat collected by the pulse sensor will be transformed into digital signal from analog signal, and then can be processed and displayed after transported to the personal computer through the Zigbee wireless communicate units. The data will be retrieval and playback for the measurement of psychology. The experiments show that the device is able to acquire the pulse wave of the human body in real-time, at the same time, through the ZigBee wireless network, it can accomplish real-time, secure and reliable communications, and it also can be used in the research of testing the mental state of the individual. Through the application of the ZigBee communicate technology; the psychology tester can collect the pulse signal to reflect the individual's mental state in different conditions. So it will be applicable to a wide range of psychology measurement and other areas.
Rolling-element fatigue life of AMS 5749 corrosion resistant, high temperature bearing steel
NASA Technical Reports Server (NTRS)
Parker, R. J.; Hodder, R. S.
1977-01-01
The rolling element fatigue lives of AMS 5749 and AISI M-50 were compared in tests run in the five ball fatigue tester and the rolling contact fatigue tester. The effects of double vacuum melting and retained austenite on the life of AMS 5749 were determined in five ball fatigue tests. The double vacuum melting process consisted of induction vacuum melting followed by vacuum arc remelting (VIM-VAR). In the five ball tests, VIM-VAR AMS 5749 gave lives at least six times that of VIM-VAR AISI M-50. Similar tests in the rolling contact fatigue tester showed no significant difference in the lives of the two materials. The rolling element fatigue life of VIM-VAR AMS 5749 was at least 14 times that of vacuum induction melted AMS 5749. A trend toward increased rolling element fatigue life with decreased retained austenite is apparent, but the confidence that all experimental differences are significant is not great.
Synthesized multi-station tribo-test system for bio-tribological evaluation in vitro
NASA Astrophysics Data System (ADS)
Wu, Tonghai; Du, Ying; Li, Yang; Wang, Shuo; Zhang, Zhinan
2016-07-01
Tribological tests play an important role on the evaluation of long-term bio-tribological performances of prosthetic materials for commercial fabrication. Those tests focus on the motion simulation of a real joint in vitro with only normal loads and constant velocities, which are far from the real friction behavior of human joints characterized with variable loads and multiple directions. In order to accurately obtain the bio-tribological performances of artificial joint materials, a tribological tester with a miniature four-station tribological system is proposed with four distinctive features. Firstly, comparability and repeatability of a test are ensured by four equal stations of the tester. Secondly, cross-linked scratch between tribo-pairs of human joints can be simulated by using a gear-rack meshing mechanism to produce composite motions. With this mechanism, the friction tracks can be designed by varying reciprocating and rotating speeds. Thirdly, variable loading system is realized by using a ball-screw mechanism driven by a stepper motor, by which loads under different gaits during walking are simulated. Fourthly, dynamic friction force and normal load can be measured simultaneously. The verifications of the performances of the developed tester show that the variable frictional tracks can produce different wear debris compared with one-directional tracks, and the accuracy of loading and friction force is within ±5%. Thus the high consistency among different stations can be obtained. Practically, the proposed tester system could provide more comprehensive and accurate bio-tribological evaluations for prosthetic materials.
Glasman, Laura R; Dickson-Gomez, Julia; Lechuga, Julia; Tarima, Sergey; Bodnar, Gloria; de Mendoza, Lorena Rivas
2016-06-01
In El Salvador, crack users are at high risk for HIV but they are not targeted by efforts to promote early HIV diagnosis. We evaluated the promise of peer-referral chains with incentives to increase HIV testing and identify undiagnosed HIV infections among networks of crack users in San Salvador. For 14 months, we offered HIV testing in communities with a high prevalence of crack use. For the following 14 months, we promoted chains in which crack users from these communities referred their peers to HIV testing and received a small monetary incentive. We recorded the monthly numbers of HIV testers, and their crack use, sexual risk behaviors and test results. After launching the referral chains, the monthly numbers of HIV testers increased significantly (Z = 6.90, p < .001) and decayed more slowly (Z = 5.93, p < .001), and the total number of crack-using testers increased nearly fourfold. Testers in the peer-referral period reported fewer HIV risk behaviors, but a similar percentage (~5 %) tested HIV positive in both periods. More women than men received an HIV-positive diagnosis throughout the study (χ(2)(1, N = 799) = 4.23, p = .040). Peer-referral chains with incentives can potentially increase HIV testing among networks of crack users while retaining a focus on high-risk individuals.
Framework Design of Unified Cross-Authentication Based on the Fourth Platform Integrated Payment
NASA Astrophysics Data System (ADS)
Yong, Xu; Yujin, He
The essay advances a unified authentication based on the fourth integrated payment platform. The research aims at improving the compatibility of the authentication in electronic business and providing a reference for the establishment of credit system by seeking a way to carry out a standard unified authentication on a integrated payment platform. The essay introduces the concept of the forth integrated payment platform and finally put forward the whole structure and different components. The main issue of the essay is about the design of the credit system of the fourth integrated payment platform and the PKI/CA structure design.
Programmable data collection platform study
NASA Technical Reports Server (NTRS)
1976-01-01
The results of a feasibility study incorporating microprocessors in data collection platforms in described. An introduction to microcomputer hardware and software concepts is provided. The influence of microprocessor technology on the design of programmable data collection platform hardware is discussed. A standard modular PDCP design capable of meeting the design goals is proposed, and the process of developing PDCP programs is examined. A description of design and construction of the UT PDCP development system is given.
Development of Decision Analysis Specifically for Arctic Offshore Drilling Islands.
1985-12-01
the decision analysis method will - give tradeoffs between costs and design wave height, production and depth • :of water for an oil platform , etc...optimizing the type of platform that is best suited for a particular site has become an extremely difficult decision. Over fifty- one different types of...drilling and production platforms have been identified for the Arctic environment, with new concepts being developed - every year, Boslov et al (198j
Shimada, T; Yamazaki, H; Oda, Y; Hiratsuka, A; Watabe, T; Guengerich, F P
1996-01-01
A newly developed tester Salmonella typhimurium NM5004 strain was constructed by introducing a plasmid containing both rat GSH S-transferase (GST) 5-5 cDNA and the umuC"lacZ operon into the host strain Salmonella typhimurium TA1535 and used to examine whether or not GST modified the genotoxic activities of several dihaloalkanes and other compounds. Twenty-nine chemicals that were suggested to be conjugated by GST were compared with regard to their abilities to induce umu gene expression and cause cytotoxicity responses in both the NM5004 strain and the original tester strain (S. typhimurium TA1535/pSK1002, which is devoid of GST activity toward 1,2-epoxy-3-(4'-nitrophenoxy)propane). Ten chemicals--1,2-dibromoethane,N-(2,3-epoxypropyl)phthalimide, 1,3-dichloroacetone, CH2I2, 1,2-epoxy-3-phenoxypropane, 2,3-epoxypropyl p-methoxyphenyl ether, 1-bromo-2-chloroethane, 1-bromo-2,3-dichloropropane, CH2BrCl, and CH2Br2--were found to enhance induction of umu gene expression in the NM5004 strain as compared with the TA1535/pSK1002 strain. 1,2-Epoxy-3-(4'-nitrophenoxy)propane and 2,3-dibromo-1-chloropropane were inactivated by GST 5-5 in the NM5004 tester strain, although these chemicals were cytotoxic in both tester strains. Roles of GST 5-5 were also examined for the inactivation of reactive metabolites of several procarcinogens that were formed through oxidation by liver microsomes of polychlorinated biphenyl-treated rats. The results suggest that reactive metabolites (possibly epoxides) of aflatoxin B1, sterigmatocystin, 1,2-dihydro-1,2-dihydroxy-6-aminochrysene, and (+)- and (-)-enantiomers of 7,8-dihydroxy-7,8-dihydrobenzo[a]pyrene could be trapped as inactivated GSH conjugates in the NM5004 strain. High-performance liquid chromatographic analysis suggested that exo-aflatoxin B1-8,9-oxide--GSH conjugate was formed during the oxidation of aflatoxin B1 by rat and human liver microsomes in the presence of GSH and several GST enzymes including purified rat theta class GST Yrs-Yrs and rat liver GST (a mixture of alpha and mu class enzymes). Thus, the present results support the view that the theta class rat GST 5-5 enzyme participates in the activation and inactivation of potential environmental carcinogenic chemicals. This newly developed NM5004 tester strain is of use in the elucidation of roles of GST 5-5 in transformations.
NASA Astrophysics Data System (ADS)
Waldmann, H. C.; Montenegro, S.
2016-02-01
Autonomous platforms get a growing importance for ocean observing tasks in particular to enable long-term observing tasks. Employing the mobility of those platforms allows a targeted investigations of phenomena that up to now are mainly seen from satellite but are lacking detailed scrutiny. As part oft he national funded project ROBEX new operation concepts for mobile platforms are developed in particular a new type of underwater glider with larger payload capacity compared to legacy systems will be developed. First tests in the pool of a aparticular hull shape have led to a better understanding oft he hydrodynamic condition and an optomized hull design was derived from that. The WAVEGLIDER system of Liquid Robotics lends itsself to be used as a communication hub and a platform to track underwater vehicles. Therefore the combination of those systems are currently assessed in regard to a possible operation and its hard- and software implementation. A major issue ist o achieve a coordinated displacement of these completely decoupled systems. Issues on how to mitigate faulty mission runs, coping with low communication bandwidths, and ensuring adequate positioning information about the underwater glider have to be addressed. Robotic concepts known from terrestrial applications like for UAV systems are tested under the more stringent environmental conditions in ocean waters. With this combination of WAVEGLIDER and underwater glider it is planned to carry out long-term missions to investigate biochemical processes in the water column in particular to investigate the particle transport through the water column and the processes resulting from that. Concepts and first results of those tasks will be presented.
NASA Astrophysics Data System (ADS)
Natali, S.; Mantovani, S.; Barboni, D.; Hogan, P.
2017-12-01
In 1999, US Vice-President Al Gore outlined the concept of `Digital Earth' as a multi-resolution, three-dimensional representation of the planet to find, visualise and make sense of vast amounts of geo- referenced information on physical and social environments, allowing to navigate through space and time, accessing historical and forecast data to support scientists, policy-makers, and any other user. The eodataservice platform (http://eodataservice.org/) implements the Digital Earth Concept: eodatasevice is a cross-domain platform that makes available a large set of multi-year global environmental collections allowing data discovery, visualization, combination, processing and download. It implements a "virtual datacube" approach where data stored on distributed data centers are made available via standardized OGC-compliant interfaces. Dedicated web-based Graphic User Interfaces (based on the ESA-NASA WebWorldWind technology) as well as web-based notebooks (e.g. Jupyter notebook), deskop GIS tools and command line interfaces can be used to access and manipulate the data. The platform can be fully customized on users' needs. So far eodataservice has been used for the following thematic applications: High resolution satellite data distribution Land surface monitoring using SAR surface deformation data Atmosphere, ocean and climate applications Climate-health applications Urban Environment monitoring Safeguard of cultural heritage sites Support to farmers and (re)-insurances in the agriculturés field In the current work, the EO Data Service concept is presented as key enabling technology; furthermore various examples are provided to demonstrate the high level of interdisciplinarity of the platform.
Conceptual design study Science and Application Space Platform SASP. Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
Runge, F. C.
1980-01-01
The system design philosphy applied in the development of this platform concept is summarized. The system is to provide for simple, low cost, initial capability of accommodating Spacelab payloads that are modified for long duration flight. The supporting research and technology are also summarized.
NASA Technical Reports Server (NTRS)
Litt, Jonathan S.; Wong, Edmond; Krasowski, Michael J.; Greer, Lawrence C.
2003-01-01
Cooperative behavior algorithms utilizing swarm intelligence are being developed for mobile sensor platforms to inspect jet engines on-wing. Experiments are planned in which several relatively simple autonomous platforms will work together in a coordinated fashion to carry out complex maintenance-type tasks within the constrained working environment modeled on the interior of a turbofan engine. The algorithms will emphasize distribution of the tasks among multiple units; they will be scalable and flexible so that units may be added in the future; and will be designed to operate on an individual unit level to produce the desired global effect. This proof of concept demonstration will validate the algorithms and provide justification for further miniaturization and specialization of the hardware toward the true application of on-wing in situ turbine engine maintenance.
Simulator platform for fast reactor operation and safety technology demonstration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vilim, R. B.; Park, Y. S.; Grandy, C.
2012-07-30
A simulator platform for visualization and demonstration of innovative concepts in fast reactor technology is described. The objective is to make more accessible the workings of fast reactor technology innovations and to do so in a human factors environment that uses state-of-the art visualization technologies. In this work the computer codes in use at Argonne National Laboratory (ANL) for the design of fast reactor systems are being integrated to run on this platform. This includes linking reactor systems codes with mechanical structures codes and using advanced graphics to depict the thermo-hydraulic-structure interactions that give rise to an inherently safe responsemore » to upsets. It also includes visualization of mechanical systems operation including advanced concepts that make use of robotics for operations, in-service inspection, and maintenance.« less
Localization of a mobile laser scanner via dimensional reduction
NASA Astrophysics Data System (ADS)
Lehtola, Ville V.; Virtanen, Juho-Pekka; Vaaja, Matti T.; Hyyppä, Hannu; Nüchter, Andreas
2016-11-01
We extend the concept of intrinsic localization from a theoretical one-dimensional (1D) solution onto a 2D manifold that is embedded in a 3D space, and then recover the full six degrees of freedom for a mobile laser scanner with a simultaneous localization and mapping algorithm (SLAM). By intrinsic localization, we mean that no reference coordinate system, such as global navigation satellite system (GNSS), nor inertial measurement unit (IMU) are used. Experiments are conducted with a 2D laser scanner mounted on a rolling prototype platform, VILMA. The concept offers potential in being extendable to other wheeled platforms.
Damping Goes the Distance in Golf
NASA Technical Reports Server (NTRS)
2004-01-01
In the late 1980s, Dr. Benjamin Dolgin of NASA s Jet Propulsion Laboratory developed a concept for a high-damping graphite/viscoelastic material for the Strategic Defense Initiative (popularly referred to as "Star Wars"), as part of a space-based laser anti-missile program called "Asterix." Dolgin drummed up this concept with the intention of stabilizing weapons launch platforms in space, where there is no solid ground to firmly support these structures. Without the inclusion of high-damping material, the orbital platforms were said to vibrate for 20 minutes after force was applied - a rate deemed "unacceptable" by leaders of the Strategic Defense Initiative.
Design of a dynamic test platform for autonomous robot vision systems
NASA Technical Reports Server (NTRS)
Rich, G. C.
1980-01-01
The concept and design of a dynamic test platform for development and evluation of a robot vision system is discussed. The platform is to serve as a diagnostic and developmental tool for future work with the RPI Mars Rover's multi laser/multi detector vision system. The platform allows testing of the vision system while its attitude is varied, statically or periodically. The vision system is mounted on the test platform. It can then be subjected to a wide variety of simulated can thus be examined in a controlled, quantitative fashion. Defining and modeling Rover motions and designing the platform to emulate these motions are also discussed. Individual aspects of the design process are treated separately, as structural, driving linkages, and motors and transmissions.
Lunar surface structural concepts and construction studies
NASA Technical Reports Server (NTRS)
Mikulas, Martin
1991-01-01
The topics are presented in viewgraph form and include the following: lunar surface structures construction research areas; lunar crane related disciplines; shortcomings of typical mobile crane in lunar base applications; candidate crane cable suspension systems; NIST six-cable suspension crane; numerical example of natural frequency; the incorporation of two new features for improved performance of the counter-balanced actively-controlled lunar crane; lunar crane pendulum mechanics; simulation results; 1/6 scale lunar crane testbed using GE robot for global manipulation; basic deployable truss approaches; bi-pantograph elevator platform; comparison of elevator platforms; perspective of bi-pantograph beam; bi-pantograph synchronously deployable tower/beam; lunar module off-loading concept; module off-loader concept packaged; starburst deployable precision reflector; 3-ring reflector deployment scheme; cross-section of packaged starburst reflector; and focal point and thickness packaging considerations.
C-SPECT - a Clinical Cardiac SPECT/Tct Platform: Design Concepts and Performance Potential
Chang, Wei; Ordonez, Caesar E.; Liang, Haoning; Li, Yusheng; Liu, Jingai
2013-01-01
Because of scarcity of photons emitted from the heart, clinical cardiac SPECT imaging is mainly limited by photon statistics. The sub-optimal detection efficiency of current SPECT systems not only limits the quality of clinical cardiac SPECT imaging but also makes more advanced potential applications difficult to be realized. We propose a high-performance system platform - C-SPECT, which has its sampling geometry optimized for detection of emitted photons in quality and quantity. The C-SPECT has a stationary C-shaped gantry that surrounds the left-front side of a patient’s thorax. The stationary C-shaped collimator and detector systems in the gantry provide effective and efficient detection and sampling of photon emission. For cardiac imaging, the C-SPECT platform could achieve 2 to 4 times the system geometric efficiency of conventional SPECT systems at the same sampling resolution. This platform also includes an integrated transmission CT for attenuation correction. The ability of C-SPECT systems to perform sequential high-quality emission and transmission imaging could bring cost-effective high-performance to clinical imaging. In addition, a C-SPECT system could provide high detection efficiency to accommodate fast acquisition rate for gated and dynamic cardiac imaging. This paper describes the design concepts and performance potential of C-SPECT, and illustrates how these concepts can be implemented in a basic system. PMID:23885129
Cryogenic gear technology for an orbital transfer vehicle engine and tester design
NASA Technical Reports Server (NTRS)
Calandra, M.; Duncan, G.
1986-01-01
Technology available for gears used in advanced Orbital Transfer Vehicle rocket engines and the design of a cryogenic adapted tester used for evaluating advanced gears are presented. The only high-speed, unlubricated gears currently in cryogenic service are used in the RL10 rocket engine turbomachinery. Advanced rocket engine gear systems experience operational load conditions and rotational speed that are beyond current experience levels. The work under this task consisted of a technology assessment and requirements definition followed by design of a self-contained portable cryogenic adapted gear test rig system.
Reducing software security risk through an integrated approach
NASA Technical Reports Server (NTRS)
Gilliam, D.; Powell, J.; Kelly, J.; Bishop, M.
2001-01-01
The fourth quarter delivery, FY'01 for this RTOP is a Property-Based Testing (PBT), 'Tester's Assistant' (TA). The TA tool is to be used to check compiled and pre-compiled code for potential security weaknesses that could be exploited by hackers. The TA Instrumenter, implemented mostly in C++ (with a small part in Java), parsels two types of files: Java and TASPEC. Security properties to be checked are written in TASPEC. The Instrumenter is used in conjunction with the Tester's Assistant Specification (TASpec)execution monitor to verify the security properties of a given program.
Wilson, Michael; Masia, Ricard; Moloo, Zahir; Stall, Jennifer; Eslan, Alexia; Ayers, Stephanie; Mutuku, Angela
2017-01-01
Background Case-based learning (CBL) is an established pedagogical active learning method used in various disciplines and defined based on the field of study and type of case. The utility of CBL for teaching specific aspects of cancer diagnosis to practising pathologists has not been previously studied in sub-Saharan Africa. Objectives We aimed to pilot test standardised cancer cases on a group of practising pathologists in sub-Saharan Africa to evaluate case content, clarity of questions and delivery of content. Methods Expert faculty created cases for the four most commonly diagnosed cancers. The format included mini-cases and bullet cases which were all open-ended. The questions dealt with interpretation of clinical information, gross specimen examination, morphologic characteristics of tumours, ancillary testing, reporting and appropriate communication to clinicians. Results Cases on breast, cervical, prostate and colorectal cancers were tested on seven practising pathologists. Each case took an average of 45–90 min to complete. Questions that were particularly challenging to testers were on: Specimens they should have been but for some reason were not exposed to in routine practice.Ancillary testing and appropriate tumour staging. New knowledge gained included tumour grading and assessment of radial margins. Revisions to cases were made based on testers’ feedback, which included rewording of questions to reduce ambiguity and adding of tables to clarify concepts. Conclusion Cases were created for CBL in Kenya, but these are applicable elsewhere in Africa and beyond to teach cancer diagnosis. The pilot testing of cases prepared faculty for the actual CBL course and feedback provided by the testers assisted in improving the questions and impact on day-to-day practice. PMID:29147646
(abstract) Tropospheric Emission Spectrometer (TES)
NASA Technical Reports Server (NTRS)
Beer, Reinhard
1994-01-01
A descope of the EOS program now requires that all EOS platforms after AM1 be launched on DELTA-class vehicles, which results in much smaller platforms (and payloads) than previously envisaged. A major part of the TES hardware design effort has therefore been redirected towards meeting this challenge. The development of the TES concept continues on a schedule to permit flight on the EOS CHEM platform in 2002, where it is planned to be accompanied by HIRDLS and MLS.
NASA Technical Reports Server (NTRS)
Abbott, David; Batten, Adam; Carpenter, David; Dunlop, John; Edwards, Graeme; Farmer, Tony; Gaffney, Bruce; Hedley, Mark; Hoschke, Nigel; Isaacs, Peter;
2008-01-01
This report describes the first phase of the implementation of the Concept Demonstrator. The Concept Demonstrator system is a powerful and flexible experimental test-bed platform for developing sensors, communications systems, and multi-agent based algorithms for an intelligent vehicle health monitoring system for deployment in aerospace vehicles. The Concept Demonstrator contains sensors and processing hardware distributed throughout the structure, and uses multi-agent algorithms to characterize impacts and determine an appropriate response to these impacts.
Using GoNoodle to Introduce Health Concepts in the K-5 Classroom
ERIC Educational Resources Information Center
Whitney, Elizabeth A.
2016-01-01
This article introduces readers to the GoNoodle platform for incorporating physical activity throughout the school day, and describes how one of the features, Ultimate Champ Training, can be used to teach health concepts in the elementary school classroom.
Next generation platforms for high-throughput biodosimetry
Repin, Mikhail; Turner, Helen C.; Garty, Guy; Brenner, David J.
2014-01-01
Here the general concept of the combined use of plates and tubes in racks compatible with the American National Standards Institute/the Society for Laboratory Automation and Screening microplate formats as the next generation platforms for increasing the throughput of biodosimetry assays was described. These platforms can be used at different stages of biodosimetry assays starting from blood collection into microtubes organised in standardised racks and ending with the cytogenetic analysis of samples in standardised multiwell and multichannel plates. Robotically friendly platforms can be used for different biodosimetry assays in minimally equipped laboratories and on cost-effective automated universal biotech systems. PMID:24837249
NASA Astrophysics Data System (ADS)
Gonçalves, Vânia
The environments of software development and software provision are shifting to Web-based platforms supported by Platform/Software as a Service (PaaS/SaaS) models. This paper will make the case that there is equally an opportunity for mobile operators to identify additional sources of revenue by exposing network functionalities through Web-based service platforms. By elaborating on the concepts, benefits and risks of SaaS and PaaS, several factors that should be taken into consideration in applying these models to the telecom world are delineated.
Youth Agency and Adult Influence: A Critical Revision of Little Publics
ERIC Educational Resources Information Center
Hickey-Moody, Anna
2016-01-01
In this article, the author strengthens and develops the theoretical platform for her concept of little public spheres. Hickey-Moody does so in order to present the concept as a tool for theorists who want to consider the political significance of marginalized youth. The concept of little publics is a theoretical frame the author developed to show…
GOATS 2008 Autonomous, Adaptive Multistatic Acoustic Sensing
2008-09-30
To develop net-centric, autonomous underwater vehicle sensing concepts for littoral MCM and ASW, exploiting collaborative and environmentally...unlimited 13. SUPPLEMENTARY NOTES code 1 only 14. ABSTRACT To develop net-centric, autonomous underwater vehicle sensing concepts for littoral MCM and...of autonomous underwater vehicle networks as platforms for new sonar concepts exploring the full 3-D acoustic environment of shallow water (SW) and
Money, Arthur G; Barnett, Julie; Kuljis, Jasna; Duffin, Debbie
2015-12-01
Government initiatives see the provision of technology-assisted self-care as one of the key areas in which there is capacity for improving quality of care whilst reducing costs. However, levels of patient engagement in self-testing and management (STM) remain low. Little emphasis has been placed on understanding the patients' perspectives of the reasons for this limited engagement. Typically, patient engagement in STM is achieved via the provision of patient education programmes, which aim to enable patients to make the changes necessary to become competent self-carers. However, placing the onus to change on the individual patient is unrealistic. If levels of patient engagement are to be improved, patient needs and expectations of clinical services must be better understood and service provision must be adapted accordingly. Explore patient perceptions and expectations of clinical service provision and their views of having and making choices about care. Participants [N = 191, 103 patient self-tester managers (PSTMs) and 87 clinic-based testers (CBTs)] completed the SERVQUAL and ChQ instruments to capture perspectives on service quality and choice, respectively. A comparative statistical analysis explored the similarities and differences between PSTMs' and CBTs' responses. Clinic-based testers' perceptions of service quality were significantly more positive than PSTMs', as were their expectations of the 'tangible' aspects of service delivery. PSTMs' expectations of service quality were significantly higher than their perceptions. PSTMs attributed significantly more value to making choices compared with CBTs. To close the gap between PSTMs expectations and perceptions of service quality and better cater for their choice preferences, service providers may benefit from taking into account the following practice considerations: maintain frequent, timely, personalised and direct interactions with PSTMs; prioritise investment in resources to facilitate patient/practitioner interaction over tangible facilities; ensure that PSTMs are given the opportunity to make choices about their care. © 2015 The Authors. Scandinavian Journal of Caring Sciences published by John Wiley & Sons Ltd on behalf of Nordic College of Caring Science.
Exploring Operational Test and Evaluation of Unmanned Aircraft Systems: A Qualitative Case Study
NASA Astrophysics Data System (ADS)
Saliceti, Jose A.
The purpose of this qualitative case study was to explore and identify strategies that may potentially remedy operational test and evaluation procedures used to evaluate Unmanned Aircraft Systems (UAS) technology. The sample for analysis consisted of organizations testing and evaluating UASs (e.g., U.S. Air Force, U.S. Navy, U.S. Army, U.S. Marine Corps, U.S. Coast Guard, and Customs Border Protection). A purposeful sampling technique was used to select 15 subject matter experts in the field of operational test and evaluation of UASs. A questionnaire was provided to participants to construct a descriptive and robust research. Analysis of responses revealed themes related to each research question. Findings revealed operational testers utilized requirements documents to extrapolate measures for testing UAS technology and develop critical operational issues. The requirements documents were (a) developed without the contribution of stakeholders and operational testers, (b) developed with vague or unrealistic measures, and (c) developed without a systematic method to derive requirements from mission tasks. Four approaches are recommended to develop testable operational requirements and assist operational testers: (a) use a mission task analysis tool to derive requirements for mission essential tasks for the system, (b) exercise collaboration among stakeholders and testers to ensure testable operational requirements based on mission tasks, (c) ensure testable measures are used in requirements documents, and (d) create a repository list of critical operational issues by mission areas. The preparation of operational test and evaluation processes for UAS technology is not uniform across testers. The processes in place are not standardized, thus test plan preparation and reporting are different among participants. A standard method to prepare and report UAS technology should be used when preparing and reporting on UAS technology. Using a systematic process, such as mission-based test design, resonated among participants as an analytical method to link UAS mission tasks and measures of performance to the capabilities of the system under test when developing operational test plans. Further research should examine system engineering designs for system requirements traceability matrix of mission tasks and subtasks while using an analysis tool that adequately evaluates UASs with an acceptable level of confidence in the results.
A Service-Based Program Evaluation Platform for Enhancing Student Engagement in Assignments
ERIC Educational Resources Information Center
Wu, Ye-Chi; Ma, Lee Wei; Jiau, Hewijin Christine
2013-01-01
Programming assignments are commonly used in computer science education to encourage students to practice target concepts and evaluate their learning status. Ensuring students are engaged in such assignments is critical in attracting and retaining students. To this end, WebHat, a service-based program evaluation platform, is introduced in this…
A Platform for Learning Internet of Things
ERIC Educational Resources Information Center
Bogdanovic, Zorica; Simic, Konstantin; Milutinovic, Miloš; Radenkovic, Božidar; Despotovic-Zrakic, Marijana
2014-01-01
This paper presents a model for conducting Internet of Things (IoT) classes based on a web-service oriented cloud platform. The goal of the designed model is to provide university students with knowledge about IoT concepts, possibilities, and business models, and allow them to develop basic system prototypes using general-purpose microdevices and…
NASA Technical Reports Server (NTRS)
Bandurski, R. S.; Singh, N.
1983-01-01
A major laboratory dedicated to biological-medical research is proposed for the Space Platform. The laboratory would focus on sensor physiology and biochemistry since sensory physiology represents the first impact of the new space environment on living organisms. Microgravity and the high radiation environment of space would be used to help solve the problems of prolonged sojourns in space but, more importantly, to help solve terrestrial problems of human health and agricultural productivity. The emphasis would be on experimental use of microorganisms and small plants and small animals to minimize the space and time required to use the Space Platform for maximum human betterment. The Alpha Helix Concept, that is, the use of the Space Platform to bring experimental biomedicine to a new and extreme frontier is introduced so as to better understand the worldly environment. Staffing and instrumenting the Space Platform biomedical laboratory in a manner patterned after successful terrestrial sensory physiology laboratories is also proposed.
NASA Astrophysics Data System (ADS)
Bandurski, R. S.; Singh, N.
1983-10-01
A major laboratory dedicated to biological-medical research is proposed for the Space Platform. The laboratory would focus on sensor physiology and biochemistry since sensory physiology represents the first impact of the new space environment on living organisms. Microgravity and the high radiation environment of space would be used to help solve the problems of prolonged sojourns in space but, more importantly, to help solve terrestrial problems of human health and agricultural productivity. The emphasis would be on experimental use of microorganisms and small plants and small animals to minimize the space and time required to use the Space Platform for maximum human betterment. The Alpha Helix Concept, that is, the use of the Space Platform to bring experimental biomedicine to a new and extreme frontier is introduced so as to better understand the worldly environment. Staffing and instrumenting the Space Platform biomedical laboratory in a manner patterned after successful terrestrial sensory physiology laboratories is also proposed.
Wang, Zixin; Lau, Joseph T F; She, Rui; Ip, Mary; Jiang, Hui; Ho, Shara P Y; Yang, XueYing
2018-01-01
Human immunodeficiency virus (HIV) testing is an important global prevention strategy but underutilized by local men who have sex with men (MSM). This study investigated the prevalence of behavioral intention to take up HIV testing (specific or any type), in the next six months among MSM who had not been tested for HIV in the last three years (never-testers) in Hong Kong. The data was based on 141 never-testers of 430 MSM who completed the anonymous baseline telephone survey of an ongoing randomized controlled trial from January 2015 to August 2015. Only 17.7% of them showed strong intention to take up any type of HIV testing in the next six months. Adjusted analysis showed that perceived benefit of HIV testing (adjusted odds ratio [AOR]: 1.29, 95% confidence interval [CI]: 1.01, 1.66), perceived psychological barriers of HIV testing (AOR: 0.85, 95%CI: 0.73, 1.00), and perceived self-efficacy in taking up HIV testing (AOR: 1.28, 95%CI: 1.07, 1.52) were significantly associated with behavioral intention to take up any HIV testing. Perceived cue to action from non-governmental organization staff was positively associated with a marginal p-value of 0.077 (AOR: 2.37, 95%CI: 0.97, 5.77). It is warranted to strengthen perceived benefit, remove psychological barriers, and increase perceived self-efficacy related to HIV testing. Innovative and effective health promotions are greatly needed to increase HIV testing coverage among never-testers.
Motivation and experiences of self-testers regarding tests for cardiovascular risk factors.
Ickenroth, Martine H P; Grispen, Janaica E J; Ronda, Gaby; Tacken, Marloes; Dinant, Geert-Jan; de Vries, Nanne K; van der Weijden, Trudy
2014-02-01
In recent years, self-tests have become increasingly available to the general public, though their value is still being debated. Because these tests are available, consumers should have access to clear information about self-testing. Examining experiences of self-testers could contribute to the development of consumer information. Detailed exploration of consumers' experiences with self-testing for cardiovascular risk factors. Semi-structured interviews with 20 consumers who had performed a self-test for glucose, cholesterol or albuminuria. The main topics of the interviews were reasons for self-testing, performing the self-test, follow-up behaviour and perceived need for information on self-testing. Data were analysed using thematic content analysis. Regarding the reason for self-testing, three types of users were distinguished: those who engaged in self-testing when a test was offered, either with or without previous knowledge about the disease or risk factor, and those who had actively decided to test and had searched for a self-test themselves. Self-testers had generally experienced no problems performing the test or interpreting the result and had considerable confidence in the result. They were easily reassured by a normal result, while an abnormal result did not automatically mean they consulted a doctor. Most participants did not feel the need for more information. Self-testers often perform tests for reassurance, without considering the disadvantages, such as the absence of professional counselling and the risk of false-positive or false-negative results. Consumer information should promote more informed and deliberate choices for self-testing. © 2011 John Wiley & Sons Ltd.
Impact E-Learning Platform Moodle on the Physic's Learning Process in the High School's Students
NASA Astrophysics Data System (ADS)
Torres-Montealban, Jonas; Ruiz-Chavarria, Gregorio; Gomez-Lozoya, Enrique Armando
2011-03-01
As a didactic proposal, moodle e-learning platform was implemented in one of two Physics High School's group at UACH, in order to show how the use of new technologies can improve the learning progress linked to physics concepts. As a result, the first group worked at the same time with inside class activities as well as outside resources from the moodle e-platform. The second group only worked with inside class activities. This teaching application was developed in six sections. Section I defines the educational framework. Section II identifies the key physic's concepts to be studied in each proposed activity. Section III describes the didactic model. Section IV displays the compared results between similarities and differences in both groups. Section VI shows the gathered information in order to be discussed as a topic related on how new technologies improve the Physic's learning process in the high school' students.
Compact handheld low-cost biosensor platform for remote health monitoring
NASA Astrophysics Data System (ADS)
Hastanin, J.; Lenaerts, C.; Gailly, P.; Jans, H.; Huang, C.; Lagae, L.; Kokkinos, D.; Fleury-Frenette, K.
2016-04-01
In this paper, we present an original concept of plasmonic-related instrumentation platform dedicated to diagnostic biosensing tests out of the laboratory. The developed instrumental platform includes both disposable one-use microfluidic affinity biochip and compact optical readout device for biochip monitoring involving mobile Internet devices for data processing and communication. The biochip includes both microfluidic and optical coupling structures formed into a single plastic slab. The microfluidic path of the biochip operates in passive capillary pumping mode. In the proof-of-concept prototype, we address specifically the sensing format involving Surface Plasmon Resonance phenomenon. The biochip is plugged in the readout device without the use of an index matching fluid. An essential advantage of the developed biochip is that its implementation involves conventional hot embossing and thin film deposition process, perfectly suited for mass production of low-cost microfluidic biochip for biochemical applications.
NASA Astrophysics Data System (ADS)
Thubaasini, P.; Rusnida, R.; Rohani, S. M.
This paper describes Linux, an open source platform used to develop and run a virtual architectural walkthrough application. It proposes some qualitative reflections and observations on the nature of Linux in the concept of Virtual Reality (VR) and on the most popular and important claims associated with the open source approach. The ultimate goal of this paper is to measure and evaluate the performance of Linux used to build the virtual architectural walkthrough and develop a proof of concept based on the result obtain through this project. Besides that, this study reveals the benefits of using Linux in the field of virtual reality and reflects a basic comparison and evaluation between Windows and Linux base operating system. Windows platform is use as a baseline to evaluate the performance of Linux. The performance of Linux is measured based on three main criteria which is frame rate, image quality and also mouse motion.
Doherty, Brenda; Csáki, Andrea; Thiele, Matthias; Zeisberger, Matthias; Schwuchow, Anka; Kobelke, Jens; Fritzsche, Wolfgang; Schmidt, Markus A
2017-02-01
Detecting small quantities of specific target molecules is of major importance within bioanalytics for efficient disease diagnostics. One promising sensing approach relies on combining plasmonically-active waveguides with microfluidics yielding an easy-to-use sensing platform. Here we introduce suspended-core fibres containing immobilised plasmonic nanoparticles surrounding the guiding core as a concept for an entirely integrated optofluidic platform for efficient refractive index sensing. Due to the extremely small optical core and the large adjacent microfluidic channels, over two orders of magnitude of nanoparticle coverage densities have been accessed with millimetre-long sample lengths showing refractive index sensitivities of 170 nm/RIU for aqueous analytes where the fibre interior is functionalised by gold nanospheres. Our concept represents a fully integrated optofluidic sensing system demanding small sample volumes and allowing for real-time analyte monitoring, both of which are highly relevant within invasive bioanalytics, particularly within molecular disease diagnostics and environmental science.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quenelle, A.; Metz, R.; Poirier, D.
1994-12-31
Due to the extended work by TOTAL, since 1971, offshore and within the Mahakam delta (East Kalimantan), several installation and platform concepts have been used. The present paper only concerns the installations at Handil and Tambora sites located in the Mahakam delta (in-shore) where water depths are between 2 and 4 meters, water current is 2 knots max. and tide is 2 meters as an average. The experience gained by the company in this kind of job made it possible to recently install in a single piece large and heavy integrated decks (up to 2,600 t) with the optimum usemore » of local skills, non-sophisticated technology and at low costs. The following shows the historical and evolutive experience of TOTAL up to now in platform concepts in this area of the world and gives, by the way, some useful information for future work.« less
NASA Technical Reports Server (NTRS)
1984-01-01
The work breakdown structure (WBS) for the Space Platform Expendables Resupply Concept Definition Study is described. The WBS consists of a list of WBS elements, a dictionary of element definitions, and an element logic diagram. The list and logic diagram identify the interrelationships of the elements. The dictionary defines the types of work that may be represented by or be classified under each specific element. The Space Platform Expendable Resupply WBS was selected mainly to support the program planning, scheduling, and costing performed in the programmatics task (task 3). The WBS is neither a statement-of-work nor a work authorization document. Rather, it is a framework around which to define requirements, plan effort, assign responsibilities, allocate and control resources, and report progress, expenditures, technical performance, and schedule performance. The WBS element definitions are independent of make-or-buy decisions, organizational structure, and activity locations unless exceptions are specifically stated.
Bussery, Justin; Denis, Leslie-Alexandre; Guillon, Benjamin; Liu, Pengfeï; Marchetti, Gino; Rahal, Ghita
2018-04-01
We describe the genesis, design and evolution of a computing platform designed and built to improve the success rate of biomedical translational research. The eTRIKS project platform was developed with the aim of building a platform that can securely host heterogeneous types of data and provide an optimal environment to run tranSMART analytical applications. Many types of data can now be hosted, including multi-OMICS data, preclinical laboratory data and clinical information, including longitudinal data sets. During the last two years, the platform has matured into a robust translational research knowledge management system that is able to host other data mining applications and support the development of new analytical tools. Copyright © 2018 Elsevier Ltd. All rights reserved.
A manned-machine space station construction concept
NASA Technical Reports Server (NTRS)
Mikulas, M. M., Jr.; Bush, H. G.; Wallsom, R. E.; Dorsey, J. T.; Rhodes, M. D.
1984-01-01
A design concept for the construction of a permanent manned space station is developed and discussed. The main considerations examined in developing the design concept are: (1) the support structure of the station be stiff enough to preclude the need for an elaborate on-orbit system to control structural response, (2) the station support structure and solar power system be compatible with existing technology, and (3) the station be capable of growing in a systematic modular fashion. The concept is developed around the assembly of truss platforms by pressure-suited astronauts operating in extravehicular activity (EVA), assisted by a machine (Assembly and Transport Vehicle, ATV) to position the astronauts at joint locations where they latch truss members in place. The ATV is a mobile platform that is attached to and moves on the station support structure using pegs attached to each truss joint. The operation of the ATV is described and a number of conceptual configurations for potential space stations are developed.
Exploiting metamaterials, plasmonics and nanoantennas concepts in silicon photonics
NASA Astrophysics Data System (ADS)
Rodríguez-Fortuño, Francisco J.; Espinosa-Soria, Alba; Martínez, Alejandro
2016-12-01
The interaction of light with subwavelength metallic nano-structures is at the heart of different current scientific hot topics, namely plasmonics, metamaterials and nanoantennas. Research in these disciplines during the last decade has given rise to new, powerful concepts providing an unprecedented degree of control over light manipulation at the nanoscale. However, only recently have these concepts been used to increase the capabilities of light processing in current photonic integrated circuits (PICs), which traditionally rely only on dielectric materials with element sizes larger than the light wavelength. Amongst the different PIC platforms, silicon photonics is expected to become mainstream, since manufacturing using well-established CMOS processes enables the mass production of low-cost PICs. In this review we discuss the benefits of introducing recent concepts arisen from the fields of metamaterials, plasmonics and nanoantennas into a silicon photonics integrated platform. We review existing works in this direction and discuss how this hybrid approach can lead to the improvement of current PICs enabling novel and disruptive applications in photonics.
Tsai, Ling-Ling; Liu, Hau-Min
2008-03-01
In this study, we investigated the feasibility of applying manual muscle testing (MMT) for bedding selection and examined the bedding effect on sleep. Four lay testers with limited training in MMT performed muscle tests for the selection of the bedding systems from five different mattresses and eight different pillows for 14 participants with mild sleep-related respiratory disturbances. For each participant individually, two bedding systems-one inducing stronger muscle forces and the other inducing weaker forces-were selected. The tester-participant pairs showed 85% and 100% agreement, respectively, for the selection of mattresses and pillows that induced the strongest muscle forces. The firmness of the mattress and the height of the pillow were significantly correlated with the body weight and body mass index of the participants for the selected strong bedding system but not for the weak bedding system. Finally, differences were observed between the strong and the weak bedding systems with regard to sleep-related respiratory disturbances and the percentage of slow-wave sleep. It was concluded that MMT can be performed by inexperienced testers for the selection of bedding systems.
Influence of wearing latex gloves on electric pulp tester readings in children.
Holan, G
1993-12-01
Electric pulp testers operated by completing an electric circuit. Latex examination gloves have been claimed to interrupt this circuit and lead to false-negative results. This study was conducted to evaluate the influence of wearing latex gloves on electric pulp tester (EPT) readings. The pulps of 80 maxillary permanent incisors of 22 children 10-13 1/2 years old were tested using the Pelton & Crane 'Vitapulp' instrument. Each tooth was tested twice: with gloves and with bare hands. Teeth failing to respond to the EPT without gloves were excluded from the study. All EPT readings ranged between 1 and 9.5. Five teeth gave the same responses with gloved and ungloved hands. Only five teeth did not respond when gloves were worn, and all of these gave readings near the top of the EPT scale when tested without gloves. The other 70 teeth presented significantly higher readings with gloves than without gloves. It is concluded that removal of examination gloves during the operation of the EPT is necessary only if no response is obtained.
Okamura, Naomi; Kobayashi, Yo; Sugano, Shigeki; Fujie, Masakatsu G
2017-07-01
Static stretching is widely performed to decrease muscle tone as a part of rehabilitation protocols. Finding out the optimal duration of static stretching is important to minimize the time required for rehabilitation therapy and it would be helpful for maintaining the patient's motivation towards daily rehabilitation tasks. Several studies have been conducted for the evaluation of static stretching; however, the recommended duration of static stretching varies widely between 15-30 s in general, because the traditional methods for the assessment of muscle tone do not monitor the continuous change in the target muscle's state. We have developed a method to monitor the viscoelasticity of one muscle continuously during static stretching, using a wearable indentation tester. In this study, we investigated a suitable signal processing method to detect the time required to change the muscle tone, utilizing the data collected using a wearable indentation tester. By calculating a viscoelastic index with a certain time window, we confirmed that the stretching duration required to bring about a decrease in muscle tone could be obtained with an accuracy in the order of 1 s.
Development of a tester for evaluation of prototype thermal cells and batteries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guidotti, R.A.
1994-10-01
A tester was developed to evaluate prototype thermal cells and batteries--especially high-voltage units--under a wide range of constant-current and constant-resistance discharge conditions. Programming of the steady-state and pulsing conditions was by software control or by hardware control via an external pulse generator. The tester was assembled from primarily Hewlett-Packard (H-P) instrumentation and was operated under H-P`s Rocky Mountain Basic (RMB). Constant-current electronic loads rated up to 4 kW (400 V at up to 100 A) were successfully used with the setup. For testing under constant-resistance conditions, power metal-oxide field-effect transistors (MOSFETs) controlled by a programmable pulse generator were used tomore » switch between steady-state and pulse loads. The pulses were digitized at up to a 50 kHz rate (20 {mu} s/pt) using high-speed DVMs; steady-state voltages were monitored with standard DVMs. This paper describes several of the test configurations used and discusses the limitations of each. Representative data are presented for a number of the test conditions.« less
NASA Astrophysics Data System (ADS)
Borecki, M.; Prus, P.; Korwin-Pawlowski, M. L.; Rychlik, A.; Kozubel, W.
2017-08-01
Modern rims and wheels are tested at the design and production stages. Tests can be performed in laboratory conditions and on the ride. In the laboratory, complex and costly equipment is used, as for example wheel balancers and impact testers. Modern wheel balancers are equipped with electronic and electro-mechanical units that enable touch-less measurement of dimensions, including precision measurement of radial and lateral wheel run-out, automatic positioning and application of the counterweights, and vehicle wheel set monitoring - tread wear, drift angles and run-out unbalance. Those tests are performed by on-wheel axis measurements with laser distance meters. The impact tester enables dropping of weights from a defined height onto a wheel. Test criteria are the loss of pressure of the tire and generation of cracks in the wheel without direct impact of the falling weights. In the present paper, a set up composed of three accelerometers, a temperature sensor and a pressure sensor is examined as the base of a wheel tester. The sensor set-up configuration, on-line diagnostic and signal transmission are discussed.
Risk of HIV infection among male sex workers in Spain
Belza, M; t for
2005-01-01
Objective: To assess HIV prevalence and predictive factors for HIV among male sex workers in Spain. Methods: In this study we analysed all male sex workers who visited HIV testing clinics in 19 Spanish cities between 2000 and 2002. The information was obtained during examination by means of a brief questionnaire. For repeating testers, only the last confirmed result was taken into account. Results: 418 male sex workers were included in the analysis; 58% visited these clinics for the first time and 42% were repeating testers. 67% were of foreign origin, mostly from Latin America (91%). 96% had had sex with men, 18% were transvestites or transsexuals, and 3.3% had used injected drugs. HIV prevalence was 12.2% (95% CI, 9.3 to 15.8%), and rose to 16.9% among first time testers. No differences in HIV prevalence were found between injecting drug users, transvestites/transsexuals, and men from foreign countries. Conclusion: Because of the high risk of HIV infection, male sex workers should be the target of specific preventive activities. Preventive and healthcare strategies that are culturally adapted to migrants are required. PMID:15681730
Robitaille, Nicolas; Jackson, Philip L; Hébert, Luc J; Mercier, Catherine; Bouyer, Laurent J; Fecteau, Shirley; Richards, Carol L; McFadyen, Bradford J
2017-10-01
This proof of concept study tested the ability of a dual task walking protocol using a recently developed avatar-based virtual reality (VR) platform to detect differences between military personnel post mild traumatic brain injury (mTBI) and healthy controls. The VR platform coordinated motion capture, an interaction and rendering system, and a projection system to present first (participant-controlled) and third person avatars within the context of a specific military patrol scene. A divided attention task was also added. A healthy control group was compared to a group with previous mTBI (both groups comprised of six military personnel) and a repeated measures ANOVA tested for differences between conditions and groups based on recognition errors, walking speed and fluidity and obstacle clearance. The VR platform was well tolerated by both groups. Walking fluidity was degraded for the control group within the more complex navigational dual tasking involving avatars, and appeared greatest in the dual tasking with the interacting avatar. This navigational behaviour was not seen in the mTBI group. The present findings show proof of concept for using avatars, particularly more interactive avatars, to expose differences in executive functioning when applying context-specific protocols (here for the military). Implications for rehabilitation Virtual reality provides a means to control context-specific factors for assessment and intervention. Adding human interaction and agency through avatars increases the ecologic nature of the virtual environment. Avatars in the present application of the Virtual Reality avatar interaction platform appear to provide a better ability to reveal differences between trained, military personal with and without mTBI.
Exploration Platform in the Earth-Moon Libration System Based on ISS
NASA Technical Reports Server (NTRS)
Raftery, Michael; Derechin, Alexander
2012-01-01
International Space Station (ISS) industry partners have been working for the past two years on concepts using ISS development methods and residual assets to support a broad range of exploration missions. These concepts have matured along with planning details for NASA's Space Launch System (SLS) and Multi-Purpose Crew Vehicle (MPCV) to allow serious consideration for a platform located in the Earth-Moon Libration (EML) system. This platform would provide a flexible basis for future exploration missions and would significantly reduce costs because it will enable re-use of expensive spacecraft and reduce the total number of launches needed to accomplish these missions. ISS provides a robust set of methods which can be used to test systems and capabilities needed for missions to the Moon, Mars, asteroids and other potential destinations. We will show how ISS can be used to reduce risk and improve operational flexibility for missions beyond low earth orbit through the development of a new Exploration Platform based in the EML system. The benefits of using the EML system as a gateway will be presented along with additional details of a lunar exploration mission concept. International cooperation is a critical enabler and ISS has already demonstrated successful management of a large multi-national technical endeavor. We will show how technology developed for ISS can be evolved and adapted to the new exploration challenge. New technology, such as electric propulsion and advanced life support systems can be tested and proven at ISS as part of an incremental development program. Finally, we will describe how the EML Platform could be built and deployed and how International access for crew and cargo could be provided.
2015-05-01
This material is based upon work funded and supported by the Department of Defense under Contract No. FA8721-05- C -0003 with Carnegie Mellon...SoS), each of us summons a slightly different im- age. Some current examples of SoS contexts illustrate the various meanings that we apply to the term...vehicles, including ships, aircraft , and ground vehicles, are considered platforms in the DoD context. The concept of “platform architecture” in this
U.S. Space Station platform - Configuration technology for customer servicing
NASA Technical Reports Server (NTRS)
Dezio, Joseph A.; Walton, Barbara A.
1987-01-01
Features of the Space Station coorbiting and polar orbiting platforms (COP and POP, respectively) are described that will allow them to be configured optimally to meet mission requirements and to be assembled, serviced, and modified on-orbit. Both of these platforms were designed to permit servicing at the Shuttle using the remote manipulator system with teleoperated end effectors; EVA was planned as a backup and for unplanned payload failure modes. Station-based servicing is discussed as well as expendable launch vehicle-based servicing concepts.
Wang, Qiang; Tan, Liying; Ma, Jing; Yu, Siyuan; Jiang, Yijun
2012-01-16
Satellite platform vibration causes the misalignment between incident direction of the beacon and optical axis of the satellite optical communication system, which also leads to the instability of the laser link and reduces the precision of the system. So how to simulate the satellite platform vibration is a very important work in the ground test of satellite optical communication systems. In general, a vibration device is used for simulating the satellite platform vibration, but the simulation effect is not ideal because of the limited randomness. An approach is reasonable, which uses a natural random process for simulating the satellite platform vibration. In this paper, we discuss feasibility of the concept that the effect of angle of arrival fluctuation is taken as an effective simulation of satellite platform vibration in the ground test of the satellite optical communication system. Spectrum characteristic of satellite platform vibration is introduced, referring to the model used by the European Space Agency (ESA) in the SILEX program and that given by National Aeronautics and Space Development Agency (NASDA) of Japan. Spectrum characteristic of angle of arrival fluctuation is analyzed based on the measured data from an 11.16km bi-directional free space laser transmission experiment. Spectrum characteristic of these two effects is compared. The results show that spectra of these two effects have similar variation trend with the variation of frequency and feasibility of the concept is proved by the comparison results. At last the procedure of this method is proposed, which uses the power spectra of angle of arrival fluctuation to simulate that of the satellite platform vibration. The new approach is good for the ground test of satellite optical communication systems.
A space-based public service platform for terrestrial rescue operations
NASA Technical Reports Server (NTRS)
Fleisig, R.; Bernstein, J.; Cramblit, D. C.
1977-01-01
The space-based Public Service Platform (PSP) is a multibeam, high-gain communications relay satellite that can provide a variety of functions for a large number of people on earth equipped with extremely small, very low cost transceivers. This paper describes the PSP concept, the rationale used to derive the concept, the criteria for selecting specific communication functions to be performed, and the advantages of performing such functions via satellite. The discussion focuses on the benefits of using a PSP for natural disaster warning; control of attendant rescue/assistance operations; and rescue of people in downed aircraft, aboard sinking ships, lost or injured on land.
NASA Technical Reports Server (NTRS)
Underwood, Matthew C.
2017-01-01
To provide justification for equipping a fleet of aircraft with avionics capable of supporting trajectory-based operations, significant flight testing must be accomplished. However, equipping aircraft with these avionics and enabling technologies to communicate the clearances required for trajectory-based operations is cost-challenging using conventional avionics approaches. This paper describes an approach to minimize the costs and risks of flight testing these technologies in-situ, discusses the test-bed platform developed, and highlights results from a proof-of-concept flight test campaign that demonstrates the feasibility and efficiency of this approach.
Regional satellite systems - Required or redundant
NASA Astrophysics Data System (ADS)
Filep, R.
1981-09-01
It is shown that the development of such regional satellite systems as the Arab League's Arabsat, the South American Aseta, and the ASEAN nations' Palapa II, will be redundant if Intelsat moves ahead with its expanded service options with multiple frequency and beam configurations. Attention is given to direct broadcast satellite systems and the geostationary platform concept, which would incorporate C-band high-volume trunking, meteorological data relay, interplatform link, and Ku-band TV distribution and could be constructed in orbit by the Space Shuttle. The platform concept offers antenna reflectors that could be utilized by many 'feeds' or multiple-phase arrays, permitting frequency reuse many hundreds of times over.
MSG: Microgravity Science Glovebox
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baugher, C.R.; Ramachandran, N.; Roark, W.
1996-12-31
The capabilities of the Space Station glovebox facility is described. Tentatively scheduled to be launched in 1999, this facility called the Microgravity Sciences Glovebox (MSG), will provide a robust and sophisticated platform for doing microgravity experiments on the Space Station. It will provide an environment not only for testing and evaluating experiment concepts, but also serve as a platform for doing fairly comprehensive science investigations. Its design has evolved substantially from the middeck glovebox, now flown on Space Shuttle missions, not only in increased experiment volume but also in significant capability enhancements. The system concept, functionality and architecture are discussedmore » along with technical information that will benefit potential science investigators.« less
Trusses Of Tensegrity Type In A Concept Of Train Station Renovation In Żary
NASA Astrophysics Data System (ADS)
Lechocka, Paulina
2015-09-01
The first railway station in Żary was built in 1843 in Germany. After the Second World War and years of socialism in Poland the meaning of railway decreased and its technical condition deteriorated. Now the building needs renovation and change of function. Tensegrity structures may be useful in renovation of platforms shelter. They are strut and tie construction, in which there is self-stabilization between compressed and tensioned elements. Conception of new platform shelter is based on exemplary tensegrity module consist of three struts and nine cables (called "Simplex"). Tensegrity would make railway station more modern, but not cover its original elevation.
Long term orbital storage of cryogenic propellants for advanced space transportation missions
NASA Technical Reports Server (NTRS)
Schuster, John R.; Brown, Norman S.
1987-01-01
A comprehensive study has developed the major features of a large capacity orbital propellant depot for the space-based, cryogenic OTV. The study has treated both the Dual-Keel Space Station and co-orbiting platforms as the accommodations base for the propellant storage facilities, and trades have examined both tethered and hard-docked options. Five tank set concepts were developed for storing the propellants, and along with layout options for the station and platform, were evaluated from the standpoints of servicing, propellant delivery, boiloff, micrometeoroid/debris shielding, development requirements, and cost. These trades led to the recommendation that an all-passive storage concept be considered for the platform and an actively refrigerated concept providing for reliquefaction of all boiloff be considered for the Space Station. The tank sets are modular, each storing up to 45,400 kg of LO2/LH2, and employ many advanced features to provide for microgravity fluid management and to limit boiloff. The features include such technologies as zero-gravity mass gauging, total communication capillary liquid acquisition devices, autogenous pressurization, thermodynamic vent systems, thick multilayer insulation, vapor-cooled shields, solar-selective coatings, advanced micrometeoroid/debris protection systems, and long-lived cryogenic refrigeration systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tibbitts, G.A.; DeLafosse, P.H.; Black, A.
1980-07-01
Four main areas of development for the project are covered: design and fabrication of a dynamometer and a mud cooling system for the Bearing-Seal Package Test Facility; modification of the Bearing-Seal Package Test Facility based on test results; testing of new lubricant samples from Pacer Lubricants, Inc., in the Terra Tek High Temperature Lubricant Tester; and testing of new seal types in the Terra Tek Sea Tester. The Maurer Engineering Report, Semi-Annual Progress Report on Improvement of Downhole Motor Bearings and Seals by Jeff L. Barnwell, has been included as Appendix B.
Comparison of strain rates of dart impacted plaques and pendulum impacted bumpers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scammell, K.L.
1987-01-01
The difference in strain rates prevailing during pendulum impact of bumpers versus high speed dart impact of plaques was investigated. Uni-axial strain gages were applied to the tension side of the plaques and bumpers directly opposite the point of impact. The plaques were impacted with an instrumented high rate dart impact tester and the bumpers impacted with a full scale bumper pendulum impact tester. Theoretical calculations and actual strain rate data support the conclusion that the strain rate of a plaque during dart impact significantly exceeds that of bumper strain rate during pendulum impact.
Missions and vehicle concepts for modern, propelled, lighter-than-air vehicles
NASA Technical Reports Server (NTRS)
Ardema, M. D.
1984-01-01
The results of studies conducted over the last 15 years to assess missions and vehicle concepts for modern, propelled, lighter-than-air vehicles (airships) were surveyed. Rigid and non-rigid airship concepts are considered. The use of airships for ocean patrol and surveillance is discussed along with vertical heavy lift airships. Military and civilian needs for high altitude platforms are addressed.
Metadata Harvesting in Regional Digital Libraries in the PIONIER Network
ERIC Educational Resources Information Center
Mazurek, Cezary; Stroinski, Maciej; Werla, Marcin; Weglarz, Jan
2006-01-01
Purpose: The paper aims to present the concept of the functionality of metadata harvesting for regional digital libraries, based on the OAI-PMH protocol. This functionality is a part of regional digital libraries platform created in Poland. The platform was required to reach one of main objectives of the Polish PIONIER Programme--to enrich the…
The Design and Implementation of Network Teaching Platform Basing on .NET
NASA Astrophysics Data System (ADS)
Yanna, Ren
This paper addresses the problem that students under traditional teaching model have poor operation ability and studies in depth the network teaching platform in domestic colleges and universities, proposing the design concept of network teaching platform of NET + C # + SQL excellent course and designing the overall structure, function module and back-end database of the platform. This paper emphatically expounds the use of MD5 encryption techniques in order to solve data security problems and the assessment of student learning using ADO.NET database access technology as well as the mathematical formula. The example shows that the network teaching platform developed by using WEB application technology has higher safety and availability, and thus improves the students' operation ability.
NASA Astrophysics Data System (ADS)
Hu, Y.; Marshak, A.; Omar, A.; Lin, B.; Baize, R.
2018-02-01
We propose a concept that will put microwave and laser transmitters on the Deep Space Gateway platform for measurements of the Earth's atmosphere and ocean. Receivers will be placed on the ground, buoys, Argo floats, and cube satellites.
Hartling, Lisa; Bond, Kenneth; Santaguida, P Lina; Viswanathan, Meera; Dryden, Donna M
2011-08-01
To develop and test a study design classification tool. We contacted relevant organizations and individuals to identify tools used to classify study designs and ranked these using predefined criteria. The highest ranked tool was a design algorithm developed, but no longer advocated, by the Cochrane Non-Randomized Studies Methods Group; this was modified to include additional study designs and decision points. We developed a reference classification for 30 studies; 6 testers applied the tool to these studies. Interrater reliability (Fleiss' κ) and accuracy against the reference classification were assessed. The tool was further revised and retested. Initial reliability was fair among the testers (κ=0.26) and the reference standard raters κ=0.33). Testing after revisions showed improved reliability (κ=0.45, moderate agreement) with improved, but still low, accuracy. The most common disagreements were whether the study design was experimental (5 of 15 studies), and whether there was a comparison of any kind (4 of 15 studies). Agreement was higher among testers who had completed graduate level training versus those who had not. The moderate reliability and low accuracy may be because of lack of clarity and comprehensiveness of the tool, inadequate reporting of the studies, and variability in tester characteristics. The results may not be generalizable to all published studies, as the test studies were selected because they had posed challenges for previous reviewers with respect to their design classification. Application of such a tool should be accompanied by training, pilot testing, and context-specific decision rules. Copyright © 2011 Elsevier Inc. All rights reserved.
Repeatability of the Oxford Foot Model in children with foot deformity.
McCahill, Jennifer; Stebbins, Julie; Koning, Bart; Harlaar, Jaap; Theologis, Tim
2018-03-01
The Oxford Foot Model (OFM) is a multi-segment, kinematic model developed to assess foot motion. It has previously been assessed for repeatability in healthy populations. To determine the OFM's reliability for detecting foot deformity, it is important to know repeatability in pathological conditions. The aim of the study was to assess the repeatability of the OFM in children with foot deformity. Intra-tester repeatability was assessed for 45 children (15 typically developing, 15 hemiplegic, 15 clubfoot). Inter-tester repeatability was assessed in the clubfoot population. The mean absolute differences between testers (clubfoot) and sessions (clubfoot and hemiplegic) were calculated for each of 15 clinically relevant, kinematic variables and compared to typically developing children. Children with clubfoot showed a mean difference between visits of 2.9° and a mean difference between raters of 3.6° Mean absolute differences were within one degree for the intra and inter-rater reliability in 12/15 variables. Hindfoot rotation, forefoot/tibia abduction and forefoot supination were the most variable between testers. Overall the clubfoot data were less variable than the typically developing population. Children with hemiplegia demonstrated slightly higher differences between sessions (mean 4.1°), with the most reliable data in the sagittal plane, and largest differences in the transverse plane. The OFM was designed to measure different types of foot deformity. The results of this study show that it provides repeatable results in children with foot deformity. To be distinguished from measurement artifact, changes in foot kinematics as a result of intervention or natural progression over time must be greater than the repeatability reported here. Copyright © 2018 Elsevier B.V. All rights reserved.
The efficacy of supplemental intraosseous anesthesia after insufficient mandibular block.
Prohić, Samir; Sulejmanagić, Halid; Secić, Sadeta
2005-02-01
It is a well-known scientific fact that only a small percentage of infiltration of inferior alveolar nerve is clinically proven to be efficient. The objective of this study was to determine the anesthetic efficacy of supplemental intraosseous injection, used after the insufficient classical mandibular block that didn't provide deep pulp anesthesia of mandibular molar planed for extraction. The experimental teeth consisted of 98 mandibular molars with clinical indication for extraction. Based on the history of disease, we indicated the extraction of the tooth. After that each tooth was tested with a electric pulp tester P1. We tested the pulp vitality and precisely determined the level of vitality. After that, each patient received classical mandibular block, and the pulp vitality was tested again. If the pulp tester indicated negative vitality for the certain mandibular molar, and the patient didn't complain about pain or discomfort during the extraction, the molar was extracted and the result was added to anesthetic success rate for the classical mandibular block. If, five minutes after receiving the mandibular block, the pulp tester indicated positive vitality (parameters of vitality) or the patient complained about pain or discomfort (parameters of pain and discomfort), we used the Stabident intraosseous anesthesia system. Three minutes after the application of supplemental intraosseous injection the molar was tested with the pulp tester again. The anesthetic solution used in both anesthetic techniques is lidocaine with 1:100.000 epinephrine. The results of this study indicate that the anesthetic efficacy of the mandibular block is 74.5%, and that supplemental intraosseous anesthesia, applied after the insufficient mandibular block, provides pulpal anesthesia in 94.9% of mandibular molars. The difference between anesthetic efficacy of the classical mandibular block and anesthetic efficacy of the supplemental intraosseous anesthesia, applied after the insufficient mandibular block, is obvious.
Poncumhak, Puttipong; Saengsuwan, Jiamjit; Amatachaya, Sugalya
2014-01-01
Background/Objectives More than half of independent ambulatory patients with spinal cord injury (SCI) need a walking device to promote levels of independence. However, long-lasting use of a walking device may introduce negative impacts for the patients. Using a standard objective test relating to the requirement of a walking device may offer a quantitative criterion to effectively monitor levels of independence of the patients. Therefore, this study investigated (1) ability of the three functional tests, including the five times sit-to-stand test (FTSST), timed up and go test (TUGT), and 10-meter walk test (10MWT) to determine the ability of walking without a walking device, and (2) the inter-tester reliability of the tests to assess functional ability in patients with SCI. Methods Sixty independent ambulatory patients with SCI, who walked with and without a walking device (30 subjects/group), were assessed cross-sectionally for their functional ability using the three tests. The first 20 subjects also participated in the inter-tester reliability test. Results The time required to complete the FTSST <14 seconds, the TUGT < 18 seconds, and the 10MWT < 6 seconds had good-to-excellent capability to determine the ability of walking without a walking device of subjects with SCI. These tests also showed excellent inter-tester reliability. Conclusions Methods of clinical evaluation for walking are likely performed using qualitative observation, which makes the results difficult to compare among testers and test intervals. Findings of this study offer a quantitative target criterion or a clear level of ability that patients with SCI could possibly walk without a walking device, which would benefit monitoring process for the patients. PMID:24621030
Saka, Masayuki; Yamauchi, Hiroki; Hoshi, Kenji; Yoshioka, Toru; Hamada, Hidetoshi; Gamada, Kazuyoshi
2015-05-01
Humeral retroversion is defined as the orientation of the humeral head relative to the distal humerus. Because none of the previous methods used to measure humeral retroversion strictly follow this definition, values obtained by these techniques vary and may be biased by morphologic variations of the humerus. The purpose of this study was 2-fold: to validate a method to define the axis of the distal humerus with a virtual cylinder and to establish the reliability of 3-dimensional (3D) measurement of humeral retroversion by this cylinder fitting method. Humeral retroversion in 14 baseball players (28 humeri) was measured by the 3D cylinder fitting method. The root mean square error was calculated to compare values obtained by a single tester and by 2 different testers using the embedded coordinate system. To establish the reliability, intraclass correlation coefficient (ICC) and precision (standard error of measurement [SEM]) were calculated. The root mean square errors for the humeral coordinate system were <1.0 mm/1.0° for comparison of all translations/rotations obtained by a single tester and <1.0 mm/2.0° for comparison obtained by 2 different testers. Assessment of reliability and precision of the 3D measurement of retroversion yielded an intratester ICC of 0.99 (SEM, 1.0°) and intertester ICC of 0.96 (SEM, 2.8°). The error in measurements obtained by a distal humerus cylinder fitting method was small enough not to affect retroversion measurement. The 3D measurement of retroversion by this method provides excellent intratester and intertester reliability. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
The reliability and validity of the Saliba Postural Classification System
Collins, Cristiana Kahl; Johnson, Vicky Saliba; Godwin, Ellen M.; Pappas, Evangelos
2016-01-01
Objectives To determine the reliability and validity of the Saliba Postural Classification System (SPCS). Methods Two physical therapists classified pictures of 100 volunteer participants standing in their habitual posture for inter and intra-tester reliability. For validity, 54 participants stood on a force plate in a habitual and a corrected posture, while a vertical force was applied through the shoulders until the clinician felt a postural give. Data were extracted at the time the give was felt and at a time in the corrected posture that matched the peak vertical ground reaction force (VGRF) in the habitual posture. Results Inter-tester reliability demonstrated 75% agreement with a Kappa = 0.64 (95% CI = 0.524–0.756, SE = 0.059). Intra-tester reliability demonstrated 87% agreement with a Kappa = 0.8, (95% CI = 0.702–0.898, SE = 0.05) and 80% agreement with a Kappa = 0.706, (95% CI = 0.594–0818, SE = 0.057). The examiner applied a significantly higher (p < 0.001) peak vertical force in the corrected posture prior to a postural give when compared to the habitual posture. Within the corrected posture, the %VGRF was higher when the test was ongoing vs. when a postural give was felt (p < 0.001). The %VGRF was not different between the two postures when comparing the peaks (p = 0.214). Discussion The SPCS has substantial agreement for inter- and intra-tester reliability and is largely a valid postural classification system as determined by the larger vertical forces in the corrected postures. Further studies on the correlation between the SPCS and diagnostic classifications are indicated. PMID:27559288
The reliability and validity of the Saliba Postural Classification System.
Collins, Cristiana Kahl; Johnson, Vicky Saliba; Godwin, Ellen M; Pappas, Evangelos
2016-07-01
To determine the reliability and validity of the Saliba Postural Classification System (SPCS). Two physical therapists classified pictures of 100 volunteer participants standing in their habitual posture for inter and intra-tester reliability. For validity, 54 participants stood on a force plate in a habitual and a corrected posture, while a vertical force was applied through the shoulders until the clinician felt a postural give. Data were extracted at the time the give was felt and at a time in the corrected posture that matched the peak vertical ground reaction force (VGRF) in the habitual posture. Inter-tester reliability demonstrated 75% agreement with a Kappa = 0.64 (95% CI = 0.524-0.756, SE = 0.059). Intra-tester reliability demonstrated 87% agreement with a Kappa = 0.8, (95% CI = 0.702-0.898, SE = 0.05) and 80% agreement with a Kappa = 0.706, (95% CI = 0.594-0818, SE = 0.057). The examiner applied a significantly higher (p < 0.001) peak vertical force in the corrected posture prior to a postural give when compared to the habitual posture. Within the corrected posture, the %VGRF was higher when the test was ongoing vs. when a postural give was felt (p < 0.001). The %VGRF was not different between the two postures when comparing the peaks (p = 0.214). The SPCS has substantial agreement for inter- and intra-tester reliability and is largely a valid postural classification system as determined by the larger vertical forces in the corrected postures. Further studies on the correlation between the SPCS and diagnostic classifications are indicated.
An overview of emerging technologies in contemporary decision support system development
NASA Astrophysics Data System (ADS)
Nursal, Ahmad Taufik; Omar, Mohd Faizal; Nawi, Mohd Nasrun Mohd
2014-12-01
The rapid development of Web technology has opened a new approach to Decision Support System (DSS) development. For instance, Social Media is one of the Web 2.0 digital platforms that allow the creation and exchanges of user-generate content through an interactive interface, high user control and mass participation. The concept and characteristics of Web 2.0 such as remote, platform-independent, context-rich and easy to use, which is fulfill the concept and purpose of DSS. This paper outlines some of the elementary concepts of Web 2.0 and social media technology which can be potentially integrated within DSS to enhance the decision-making process. Our initial investigation indicates that there is limited study attempt to embed Web 2.0 into DSS. Thus, this paper highlights the importance of Web 2.0 technology in order to foster the betterment of DSS development and its usability.
NASA Astrophysics Data System (ADS)
Davidson, N.; Golonka, P.; Przedziński, T.; Waş, Z.
2011-03-01
Theoretical predictions in high energy physics are routinely provided in the form of Monte Carlo generators. Comparisons of predictions from different programs and/or different initialization set-ups are often necessary. MC-TESTER can be used for such tests of decays of intermediate states (particles or resonances) in a semi-automated way. Since 2002 new functionalities were introduced into the package. In particular, it now works with the HepMC event record, the standard for C++ programs. The complete set-up for benchmarking the interfaces, such as interface between τ-lepton production and decay, including QED bremsstrahlung effects is shown. The example is chosen to illustrate the new options introduced into the program. From the technical perspective, our paper documents software updates and supplements previous documentation. As in the past, our test consists of two steps. Distinct Monte Carlo programs are run separately; events with decays of a chosen particle are searched, and information is stored by MC-TESTER. Then, at the analysis step, information from a pair of runs may be compared and represented in the form of tables and plots. Updates introduced in the program up to version 1.24.4 are also documented. In particular, new configuration scripts or script to combine results from multitude of runs into single information file to be used in analysis step are explained. Program summaryProgram title: MC-TESTER, version 1.23 and version 1.24.4 Catalog identifier: ADSM_v2_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADSM_v2_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 250 548 No. of bytes in distributed program, including test data, etc.: 4 290 610 Distribution format: tar.gz Programming language: C++, FORTRAN77 Tested and compiled with: gcc 3.4.6, 4.2.4 and 4.3.2 with g77/gfortran Computer: Tested on various platforms Operating system: Tested on operating systems: Linux SLC 4.6 and SLC 5, Fedora 8, Ubuntu 8.2 etc. Classification: 11.9 External routines: HepMC ( https://savannah.cern.ch/projects/hepmc/), PYTHIA8 ( http://home.thep.lu.se/~torbjorn/Pythia.html), LaTeX ( http://www.latex-project.org/) Catalog identifier of previous version: ADSM_v1_0 Journal reference of previous version: Comput. Phys. Comm. 157 (2004) 39 Does the new version supersede the previous version?: Yes Nature of problem: The decays of individual particles are well defined modules of a typical Monte Carlo program chain in high energy physics. A fast, semi-automatic way of comparing results from different programs is often desirable for the development of new programs, in order to check correctness of the installations or for discussion of uncertainties. Solution method: A typical HEP Monte Carlo program stores the generated events in event records such as HepMC, HEPEVT or PYJETS. MC-TESTER scans, event by event, the contents of the record and searches for the decays of the particle under study. The list of the found decay modes is successively incremented and histograms of all invariant masses which can be calculated from the momenta of the particle decay products are defined and filled. The outputs from the two runs of distinct programs can be later compared. A booklet of comparisons is created: for every decay channel, all histograms present in the two outputs are plotted and parameter quantifying shape difference is calculated. Its maximum over every decay channel is printed in the summary table. Reasons for new version: Interface for HepMC Event Record is introduced. Setup for benchmarking the interfaces, such as τ-lepton production and decay, including QED bremsstrahlung effects is introduced as well. This required significant changes in the algorithm. As a consequence, a new version of the code was introduced. Restrictions: Only the first 200 decay channels that were found will initialize histograms and if the multiplicity of decay products in a given channel was larger than 7, histograms will not be created for that channel. Additional comments: New features: HepMC interface, use of lists in definition of histograms and decay channels, filters for decay products or secondary decays to be omitted, bug fixing, extended flexibility in representation of program output, installation configuration scripts, merging multiple output files from separate generations. Running time: Varies substantially with the analyzed decay particle, but generally speed estimation of the old version remains valid. On a PC/Linux with 2.0 GHz processors MC-TESTER increases the run time of the τ-lepton Monte Carlo program TAUOLA by 4.0 seconds for every 100 000 analyzed events (generation itself takes 26 seconds). The analysis step takes 13 seconds; LATEX processing takes additionally 10 seconds. Generation step runs may be executed simultaneously on multiprocessor machines.
Toward a Proof of Concept Cloud Framework for Physics Applications on Blue Gene Supercomputers
NASA Astrophysics Data System (ADS)
Dreher, Patrick; Scullin, William; Vouk, Mladen
2015-09-01
Traditional high performance supercomputers are capable of delivering large sustained state-of-the-art computational resources to physics applications over extended periods of time using batch processing mode operating environments. However, today there is an increasing demand for more complex workflows that involve large fluctuations in the levels of HPC physics computational requirements during the simulations. Some of the workflow components may also require a richer set of operating system features and schedulers than normally found in a batch oriented HPC environment. This paper reports on progress toward a proof of concept design that implements a cloud framework onto BG/P and BG/Q platforms at the Argonne Leadership Computing Facility. The BG/P implementation utilizes the Kittyhawk utility and the BG/Q platform uses an experimental heterogeneous FusedOS operating system environment. Both platforms use the Virtual Computing Laboratory as the cloud computing system embedded within the supercomputer. This proof of concept design allows a cloud to be configured so that it can capitalize on the specialized infrastructure capabilities of a supercomputer and the flexible cloud configurations without resorting to virtualization. Initial testing of the proof of concept system is done using the lattice QCD MILC code. These types of user reconfigurable environments have the potential to deliver experimental schedulers and operating systems within a working HPC environment for physics computations that may be different from the native OS and schedulers on production HPC supercomputers.
Bailie, Jodie; Cunningham, Frances Clare; Bainbridge, Roxanne Gwendalyn; Passey, Megan E; Laycock, Alison Frances; Bailie, Ross Stewart; Larkins, Sarah L; Brands, Jenny S M; Ramanathan, Shanthi; Abimbola, Seye; Peiris, David
2018-01-01
Efforts to strengthen health systems require the engagement of diverse, multidisciplinary stakeholder networks. Networks provide a forum for experimentation and knowledge creation, information exchange and the spread of good ideas and practice. They might be useful in addressing complex issues or 'wicked' problems, the solutions to which go beyond the control and scope of any one agency. Innovation platforms are proposed as a novel type of network because of their diverse stakeholder composition and focus on problem solving within complex systems. Thus, they have potential applicability to health systems strengthening initiatives, even though they have been predominantly applied in the international agricultural development sector. In this paper, we compare and contrast the concept of innovation platforms with other types of networks that can be used in efforts to strengthen primary healthcare systems, such as communities of practice, practice-based research networks and quality improvement collaboratives. We reflect on our ongoing research programme that applies innovation platform concepts to drive large-scale quality improvement in primary healthcare for Aboriginal and Torres Strait Islander Australians and outline our plans for evaluation. Lessons from our experience will find resonance with others working on similar initiatives in global health.
Sensor Web Dynamic Measurement Techniques and Adaptive Observing Strategies
NASA Technical Reports Server (NTRS)
Talabac, Stephen J.
2004-01-01
Sensor Web observing systems may have the potential to significantly improve our ability to monitor, understand, and predict the evolution of rapidly evolving, transient, or variable environmental features and events. This improvement will come about by integrating novel data collection techniques, new or improved instruments, emerging communications technologies and protocols, sensor mark-up languages, and interoperable planning and scheduling systems. In contrast to today's observing systems, "event-driven" sensor webs will synthesize real- or near-real time measurements and information from other platforms and then react by reconfiguring the platforms and instruments to invoke new measurement modes and adaptive observation strategies. Similarly, "model-driven" sensor webs will utilize environmental prediction models to initiate targeted sensor measurements or to use a new observing strategy. The sensor web concept contrasts with today's data collection techniques and observing system operations concepts where independent measurements are made by remote sensing and in situ platforms that do not share, and therefore cannot act upon, potentially useful complementary sensor measurement data and platform state information. This presentation describes NASA's view of event-driven and model-driven Sensor Webs and highlights several research and development activities at the Goddard Space Flight Center.
A large array of high-performance artificial stars using airship-supported small mirrors
NASA Astrophysics Data System (ADS)
Content, Robert; Foxwell, Mark; Murray, Graham J.
2004-10-01
We propose a practical system that can provide a large number of high performance artificial stars, of the order of a few hundred, using an array of small mirrors on an airship supported platform illuminated from the ground by a laser. Our concept offers several advantages over other guide star schemes: Airborne mirror arrays can furnish tip-tilt information; they also permit a considerable reduction in the total ground-laser power required; high intensity guide stars with very small angular image size are possible; and finally they offer very low scattered parasite laser light. More basic & simpler launch-laser & AO technologies can therefore be employed, with potentially huge cost savings, with potentially significant improvement in the quality of the AO correction. The general platform scheme and suitable lift technologies are also discussed. A novel concept for achieving precise positioning is presented whereby the platform & the lifting vehicle are linked by a tether, the platform having a degree of independent control. Our proposal would employ as the lift vehicle an autonomous high altitude airship of the type currently under widespread development in the commercial sector, for use as hubs for telecommunication networks, mobile telephone relay stations, etc.
Lucklum, Ralf; Zubtsov, Mikhail; Schmidt, Marc-Peter; Mukhin, Nikolay V.; Hirsch, Soeren
2017-01-01
The current work demonstrates a novel surface acoustic wave (SAW) based phononic crystal sensor approach that allows the integration of a velocimetry-based sensor concept into single chip integrated solutions, such as Lab-on-a-Chip devices. The introduced sensor platform merges advantages of ultrasonic velocimetry analytic systems and a microacoustic sensor approach. It is based on the analysis of structural resonances in a periodic composite arrangement of microfluidic channels confined within a liquid analyte. Completed theoretical and experimental investigations show the ability to utilize periodic structure localized modes for the detection of volumetric properties of liquids and prove the efficacy of the proposed sensor concept. PMID:28946609
Oseev, Aleksandr; Lucklum, Ralf; Zubtsov, Mikhail; Schmidt, Marc-Peter; Mukhin, Nikolay V; Hirsch, Soeren
2017-09-23
The current work demonstrates a novel surface acoustic wave (SAW) based phononic crystal sensor approach that allows the integration of a velocimetry-based sensor concept into single chip integrated solutions, such as Lab-on-a-Chip devices. The introduced sensor platform merges advantages of ultrasonic velocimetry analytic systems and a microacoustic sensor approach. It is based on the analysis of structural resonances in a periodic composite arrangement of microfluidic channels confined within a liquid analyte. Completed theoretical and experimental investigations show the ability to utilize periodic structure localized modes for the detection of volumetric properties of liquids and prove the efficacy of the proposed sensor concept.
Learning to build large structures in space
NASA Technical Reports Server (NTRS)
Hagler, T.; Patterson, H. G.; Nathan, C. A.
1977-01-01
The paper examines some of the key technologies and forms of construction know-how that will have to be developed and tested for eventual application to building large structures in space. Construction of a shuttle-tended space construction/demonstration platform would comprehensively demonstrate large structure technology, develop construction capability, and furnish a construction platform for a variety of operational large structures. Completion of this platform would lead to demonstrations of the Satellite Power System (SPS) concept, including microwave transmission, fabrication of 20-m-deep beams, conductor installation, rotary joint installation, and solar blanket installation.
Evolutionary space platform concept study. Volume 2, part A: SASP special emphasis trade studies
NASA Technical Reports Server (NTRS)
1982-01-01
Efforts are in progress to define an approach to provide a simple and cost effective solution to the problem of long duration space flight. This approach involves a Space Platform in low Earth orbit, which can be tended by the Space Shuttle and which will provide, for extended periods of time, stability, utilities and access for a variety of replaceable payloads. The feasibility of an evolutionary space system which would cost effectively support unmanned payloads in groups, using a Space Platform which provides centralized basic subsystems is addressed.
NASA Technical Reports Server (NTRS)
1989-01-01
NASA Tech Brief's provided Sonics Associates, Inc. with a method of saving many hours of testing time and money. James B. Cawthon, Sonics Vice-President, read about a device developed at Ames Research Center. Sonics adapted the device and produced an effective tester that uses a clocked shift register to apply a voltage to a cable under test. This is the active part of the Ames development, and the passive is a small box containing light emitting diodes (LEDs). When connected to the other end of the tested cable, the LEDs light in the same sequence as the generator. This procedure allows the technician to immediately identify a miswired cable.
Defibrillator synchronization tester.
Demirbilek, Fatma N; Krajnak, Mike; Stolarczyk, George
2009-01-01
A defibrillator sync output signal connector provides an ECG synchronization signal that can be used by some defibrillators for the purpose of performing synchronized cardioversion [1]. This process is used to stop an abnormally fast heart rate or cardiac arrhythmia by the delivery of a therapeutic dose of electric current to the heart during the R-wave of the cardiac cycle. Timing the shock to the R-wave prevents the delivery of the shock during the vulnerable period of the cardiac cycle, which could induce ventricular fibrillation [2]. GE patient monitors include a selectable analog output feature, which provides an analog ECG or arterial blood pressure signal. The blood pressure signal can be used to synchronize balloon pumps to provide cardiac assist to post-MI patients with poor injection fraction. Proper operation requires the defibrillator sync and analog output function to be checked. Checkouts are typically done during planned maintenance and after major part replacements such as patient monitor's main CPU board. Checking out defibrillator sync signals could be done using a GE defibrillator sync tester. The defibrillator sync tester provides a loop back path for the defibrillator sync signals to be displayed on the patient monitor screen and eliminates the need for an external oscilloscope.
Bearing Tester Data Compilation Analysis, and Reporting and Bearing Math Modeling
NASA Technical Reports Server (NTRS)
1985-01-01
The magnitude and direction of fluid induced torques and forces on the 57 mm bearing cage is considered to be a contributing factor in possible cage instabilities that can produce intermittent high heating in the bearing. Analyses of the fluid forces and torques are presented. Heat generated by viscous fluid work was estimated for two flow diverter configurations and a coolant flow of 10 lbs/sec to support the thermal evaluation of the LOX Bearing Materials Tester. Results of the analysis of the LOX turbopump turbine end bearings are discussed. Coolant velocities for the no. 4 LOX turbopump turbine end bearings were estimated as a function of shaft speed and coolant flow rate. Contact angles and track width data were developed for the 57 mm bearing as functions of shaft speed, and axial and radial loads. The Advanced Dynamics of Rolling Elements (ADORE) computer program was installed on the MSFC UNIVAC 1100 and a test case successfully run. Both the text output and the plotting output were verified. The Bearing Seal and Materials Tester - Test Condition Data Base was developed. The parametric analysis of the operating characteristics of the LOX turbopump pump end bearing using the 45 mm bearing thermal model was begun.
A Method for Measuring the Hardness of the Surface Layer on Hot Forging Dies Using a Nanoindenter
NASA Astrophysics Data System (ADS)
Mencin, P.; van Tyne, C. J.; Levy, B. S.
2009-11-01
The properties and characteristics of the surface layer of forging dies are critical for understanding and controlling wear. However, the surface layer is very thin, and appropriate property measurements are difficult to obtain. The objective of the present study is to determine if nanoindenter testing provides a reliable method, which could be used to measure the surface hardness in forging die steels. To test the reliability of nanoindenter testing, nanoindenter values for two quenched and tempered steels (FX and H13) are compared to microhardness and macrohardness values. These steels were heat treated for various times to produce specimens with different values of hardness. The heat-treated specimens were tested using three different instruments—a Rockwell hardness tester for macrohardness, a Vickers hardness tester for microhardness, and a nanoindenter tester for fine scale evaluation of hardness. The results of this study indicate that nanoindenter values obtained using a Nanoindenter XP Machine with a Berkovich indenter reliably correlate with Rockwell C macrohardness values, and with Vickers HV microhardness values. Consequently, nanoindenter testing can provide reliable results for analyzing the surface layer of hot forging dies.
Determination of flash point in air and pure oxygen using an equilibrium closed bomb apparatus.
Kong, Dehong; am Ende, David J; Brenek, Steven J; Weston, Neil P
2003-08-29
The standard closed testers for flash point measurements may not be feasible for measuring flash point in special atmospheres like oxygen because the test atmosphere cannot be maintained due to leakage and the laboratory safety can be compromised. To address these limitations we developed a new "equilibrium closed bomb" (ECB). The ECB generally gives lower flash point values than standard closed cup testers as shown by the results of six flammable liquids. The present results are generally in good agreement with the values calculated from the reported lower flammability limits and the vapor pressures. Our measurements show that increased oxygen concentration had little effect on the flash points of the tested flammable liquids. While generally regarded as non-flammable because of the lack of observed flash point in standard closed cup flash point testers, dichloromethane is known to form flammable mixtures. The flash point of dichloromethane in oxygen measured in the ECB is -7.1 degrees C. The flash point of dichloromethane in air is dependent on the type and energy of the ignition source. Further research is being carried out to establish the relationship between the flash point of dichloromethane and the energy of the ignition source.
Prather, H; Harris-Hayes, M; Hunt, D; Steger-May, K; Mathew, V; Clohisy, JC
2012-01-01
Objective The objectives of this study are the following: 1) report passive hip ROM in asymptomatic young adults, 2) report the intra-tester and inter-tester reliability of hip ROM measurements among testers of multiple disciplines, 3) report the results of provocative hip tests and tester agreement. Design descriptive epidemiology study Setting tertiary university Participants Twenty-eight young adult volunteers without musculoskeletal symptoms, history of disorder or surgery involving the lumbar spine or lower extremities were enrolled and completed the study. Methods Asymptomatic young adult volunteers completed questionnaires and were examined by two blinded examiners during a single session. The testers were physical therapists and physicians. Hip range of motion and provocative tests were completed by both examiners on each hip. Main Outcome Measurements Inter and intra-rater reliability for ROM and agreement for provocative tests was determined. Results Twenty-eight asymptomatic adults with mean age 31 years old (range 18–51 years) and mean modified Harris Hip Score of 99.5 ± 1.5 and UCLA Activity score of 8.8 ± 1.2 completed the study. Intra-rater agreement was excellent for all hip range of motion measurements, with intraclass correlation coefficients (ICCs) ranging from 0.76 to 0.97 with similar agreement if the examiner was a physical therapist or a physician. Excellent inter-rater reliability was found for hip flexion ICC 0.87 (95% CI 0.78 to 0.92), supine internal rotation ICC 0.75 (95% CI 0.60 to 0.84) and prone internal rotation ICC 0.79 (95% CI 0.66 to 0.87). The least reliable measurements were supine hip abduction (ICC 0.34) and supine external rotation (ICC 0.18). Agreement between examiners ranged from 96–100% for provocative hip tests which included the hip impingement, resisted straight leg raise, FABER/Patrick’s and log roll tests. Conclusions Specific hip ROM measures show excellent inter-rater reliability and provocative hip tests show good agreement among multiple examiners and medical disciplines. Further studies are needed to assess the utilization of these measurements and tests as a part of a hip screening examination to assess for young adults at risk intra-articular hip disorders prior to the onset of degenerative changes. PMID:20970757
Impact of Vial Capping on Residual Seal Force and Container Closure Integrity.
Mathaes, Roman; Mahler, Hanns-Christian; Roggo, Yves; Ovadia, Robert; Lam, Philippe; Stauch, Oliver; Vogt, Martin; Roehl, Holger; Huwyler, Joerg; Mohl, Silke; Streubel, Alexander
2016-01-01
The vial capping process is a critical unit operation during drug product manufacturing, as it could possibly generate cosmetic defects or even affect container closure integrity. Yet there is significant variability in capping equipment and processes, and their relation to potential defects or container closure integrity has not been thoroughly studied. In this study we applied several methods-residual seal force tester, a self-developed system of a piezo force sensor measurement, and computed tomography-to characterize different container closure system combinations that had been sealed using different capping process parameter settings. Additionally, container closure integrity of these samples was measured using helium leakage (physical container closure integrity) and compared to characterization data. The different capping equipment settings lead to residual seal force values from 7 to 115 N. High residual seal force values were achieved with high capping pre-compression force and a short distance between the capping plate and plunge. The choice of container closure system influenced the obtained residual seal force values. The residual seal force tester and piezoelectric measurements showed similar trends. All vials passed physical container closure integrity testing, and no stopper rupture was seen with any of the settings applied, suggesting that container closure integrity was warranted for the studied container closure system with the chosen capping setting ranges. The vial capping process is a critical unit operation during drug product manufacturing, as it could possibly generate cosmetic defects or even affect container closure integrity. Yet there is significant variability in capping equipment and processes, and their relation to potential defects or container closure integrity has not been thoroughly studied. In this study we applied several methods-residual seal force tester, a self-developed system of a piezo force sensor measurement, and computed tomography-to characterize different container closure system combinations that had been sealed using different capping process parameter settings. The residual seal force tester can analyze a variety of different container closure systems independent of the capping equipment. An adequate and safe residual seal force range for each container closure system configuration can be established with the residual seal force tester and additional methods like computed tomography scans and leak testing. In the residual seal force range studied, the physical container closure integrity of the container closure system was warranted. © PDA, Inc. 2016.
BIOPS Interactive: An e-Learning Platform Focused on Protein Structure and DNA
ERIC Educational Resources Information Center
Pontelli, Enrico; Pinto, Jorge; Qin, Xiaoxiao; He, Jing; Bevan, David; MacCuish, Norah; MacCuish, John; Chapman, Mitch; Moreland, David
2009-01-01
One of the difficulties in teaching basic molecular biology concepts to the students with little biological background is the lack of hands-on exercises that combines the challenges of the concepts with visualization and immediate feedback. BIOPS Interactive is a web-based interactive learning environment for molecular biology that complements…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-08
... GENERAL SERVICES ADMINISTRATION [Docket 2010-0005; Sequence 14] Draft Concept for Government-Wide... Questions AGENCY: U.S. General Services Administration. ACTION: Notice; request for public comment. SUMMARY: With this notice, the U.S. General Services Administration (GSA) requests input, comment, and ideas...
Cloud manufacturing: from concept to practice
NASA Astrophysics Data System (ADS)
Ren, Lei; Zhang, Lin; Tao, Fei; Zhao, Chun; Chai, Xudong; Zhao, Xinpei
2015-02-01
The concept of cloud manufacturing is emerging as a new promising manufacturing paradigm, as well as a business model, which is reshaping the service-oriented, highly collaborative, knowledge-intensive and eco-efficient manufacturing industry. However, the basic concepts about cloud manufacturing are still in discussion. Both academia and industry will need to have a commonly accepted definition of cloud manufacturing, as well as further guidance and recommendations on how to develop and implement cloud manufacturing. In this paper, we review some of the research work and clarify some fundamental terminologies in this field. Further, we developed a cloud manufacturing systems which may serve as an application example. From a systematic and practical perspective, the key requirements of cloud manufacturing platforms are investigated, and then we propose a cloud manufacturing platform prototype, MfgCloud. Finally, a public cloud manufacturing system for small- and medium-sized enterprises (SME) is presented. This paper presents a new perspective for cloud manufacturing, as well as a cloud-to-ground solution. The integrated solution proposed in this paper, including the terminology, MfgCloud, and applications, can push forward this new paradigm from concept to practice.
OPUS One: An Intelligent Adaptive Learning Environment Using Artificial Intelligence Support
NASA Astrophysics Data System (ADS)
Pedrazzoli, Attilio
2010-06-01
AI based Tutoring and Learning Path Adaptation are well known concepts in e-Learning scenarios today and increasingly applied in modern learning environments. In order to gain more flexibility and to enhance existing e-learning platforms, the OPUS One LMS Extension package will enable a generic Intelligent Tutored Adaptive Learning Environment, based on a holistic Multidimensional Instructional Design Model (PENTHA ID Model), allowing AI based tutoring and adaptation functionality to existing Web-based e-learning systems. Relying on "real time" adapted profiles, it allows content- / course authors to apply a dynamic course design, supporting tutored, collaborative sessions and activities, as suggested by modern pedagogy. The concept presented combines a personalized level of surveillance, learning activity- and learning path adaptation suggestions to ensure the students learning motivation and learning success. The OPUS One concept allows to implement an advanced tutoring approach combining "expert based" e-tutoring with the more "personal" human tutoring function. It supplies the "Human Tutor" with precise, extended course activity data and "adaptation" suggestions based on predefined subject matter rules. The concept architecture is modular allowing a personalized platform configuration.
Innovative concepts for marginal fields (advanced monotower developments)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, M.T.; Marks, V.E.
1995-12-01
The braced monotower provides a safe, functional and cost effective solution for topsides up to 500 tonnes, with up to 8 wells and standing in water depths of up to 70 meters. It is both simple in concept and structurally efficient. The superstructure is supported by a single column which is stayed by three symmetrically orientated legs. A broad mudline base is also provided to limit pile loads. The final concept offers complete protection to the risers and conductors from ship impact, as all appurtenances are housed within the central column. The basic design philosophy of the low intervention platformmore » is to minimize the onboard equipment to that vitally needed to produce hydrocarbon. The concept eliminates the life support functions that on a normal North Sea platform can contribute up to 50% of the topside dry weight. A system of Zero Based Engineering is used that ensures each item of equipment contributes more to the NPV of the platform than the fully built-up through life cost. This effectively eliminates the operator preference factor and the ``culture`` cost.« less
A DICOM Based Collaborative Platform for Real-Time Medical Teleconsultation on Medical Images.
Maglogiannis, Ilias; Andrikos, Christos; Rassias, Georgios; Tsanakas, Panayiotis
2017-01-01
The paper deals with the design of a Web-based platform for real-time medical teleconsultation on medical images. The proposed platform combines the principles of heterogeneous Workflow Management Systems (WfMSs), the peer-to-peer networking architecture and the SPA (Single-Page Application) concept, to facilitate medical collaboration among healthcare professionals geographically distributed. The presented work leverages state-of-the-art features of the web to support peer-to-peer communication using the WebRTC (Web Real Time Communication) protocol and client-side data processing for creating an integrated collaboration environment. The paper discusses the technical details of implementation and presents the operation of the platform in practice along with some initial results.
Digital Platforms as Factor Transforming Management Models in Businesses and Industries
NASA Astrophysics Data System (ADS)
Dimitrakiev, D.; Molodchik, A. V.
2018-05-01
Increasingly, digital platforms are built into the value chain, acting as an intermediary between the manufacturer and the consumer. The paper presents tendencies and features of business model transformation in connection with management of the new digital technologies. The limitations of traditional business models and the capabilities of business models based on digital platforms and self-organization were revealed. In the study, the viability of the new business model for the dental industry was confirmed and the new concept of the branch self-organizing control system based on the information platform, blockchain, cryptocurrency and reward of target consumer is offered, including mechanisms that make the model attractive for both the consumer and the service provider.
Astro-geodetic platform for high accuracy geoid determinat ion
NASA Astrophysics Data System (ADS)
Bǎdescu, Octavian; Nedelcu, Dan Alin; Cǎlin, Alexandru; Dumitru, Paul Daniel; Cǎlin, Lavinia A.; Popescu, Marcel
The paper presents first technical realizations of a mobile platform for vertical deviation determination at a satisfactory precision and low cost. The conception of the platform was made in the framework of a project regarding CCD astro-geodetic vertical deviation for geoid determination or geoid modeling. The project with the acronym A-GEO represents a collaboration between Technical University of Civil Engineering Bucharest - Faculty of Geodesy, (TUCEB-FG), Astronomical Institute of the Romanian academy (AIRA), and a private partner GeoGIS Proiect S.R.L. The paper presents some hardware and software aspects regarding design, development, and automation of the platform, based on an electro-optical geodetic instrument, CCD observations and satellite time synchronization for astro-geodetic measurements.
A LabVIEW® based generic CT scanner control software platform.
Dierick, M; Van Loo, D; Masschaele, B; Boone, M; Van Hoorebeke, L
2010-01-01
UGCT, the Centre for X-ray tomography at Ghent University (Belgium) does research on X-ray tomography and its applications. This includes the development and construction of state-of-the-art CT scanners for scientific research. Because these scanners are built for very different purposes they differ considerably in their physical implementations. However, they all share common principle functionality. In this context a generic software platform was developed using LabVIEW® in order to provide the same interface and functionality on all scanners. This article describes the concept and features of this software, and its potential for tomography in a research setting. The core concept is to rigorously separate the abstract operation of a CT scanner from its actual physical configuration. This separation is achieved by implementing a sender-listener architecture. The advantages are that the resulting software platform is generic, scalable, highly efficient, easy to develop and to extend, and that it can be deployed on future scanners with minimal effort.
Development of Test Article Building Block (TABB) for deployable platform systems
NASA Technical Reports Server (NTRS)
Greenberg, H. S.; Barbour, R. T.
1984-01-01
The concept of a Test Article Building Block (TABB) is described. The TABB is a ground test article that is representative of a future building block that can be used to construct LEO and GEO deployable space platforms for communications and scientific payloads. This building block contains a main housing within which the entire structure, utilities, and deployment/retraction mechanism are stowed during launch. The end adapter secures the foregoing components to the housing during launch. The main housing and adapter provide the necessary building-block-to-building-block attachments for automatically deployable platforms. Removal from the shuttle cargo bay can be accomplished with the remote manipulator system (RMS) and/or the handling and positioning aid (HAPA). In this concept, all the electrical connections are in place prior to launch with automatic latches for payload attachment provided on either the end adapters or housings. The housings also can contain orbiter docking ports for payload installation and maintenance.
Wind study for high altitude platform design
NASA Technical Reports Server (NTRS)
Strganac, T. W.
1979-01-01
An analysis of upper air winds was performed to define the wind environment at potential operating altitudes for high-altitude powered platform concepts. Expected wind conditions of the contiguous United States, Pacific area (Alaska to Sea of Japan), and European area (Norwegian and Mediterranean Seas) were obtained using a representative network of sites selected based upon adequate high-altitude sampling, geographic dispersion, and observed upper wind patterns. A data base of twenty plus years of rawinsonde gathered wind information was used in the analysis. Annual variations from surface to 10 mb (approximately 31 km) pressure altitude were investigated to encompass the practical operating range for the platform concepts. Parametric analysis for the United States and foreign areas was performed to provide a basis for vehicle system design tradeoffs. This analysis of wind magnitudes indicates the feasibility of annual operation at a majority of sites and more selective seasonal operation for the extreme conditions between the pressure altitudes of 100 to 25 mb based upon the assumed design speeds.
Wind study for high altitude platform design
NASA Technical Reports Server (NTRS)
Strganac, T. W.
1979-01-01
An analysis of upper air winds was performed to define the wind environment at potential operating altitudes for high altitude powered platform concepts. Wind conditions of the continental United States, Pacific area (Alaska to Sea of Japan), and European area (Norwegian and Mediterranean Sea) were obtained using a representative network of sites selected based upon adequate high altitude sampling, geographic dispersion, and observed upper wind patterns. A data base of twenty plus years of rawinsonde gathered wind information was used in the analysis. Annual variations from surface to 10 mb pressure altitude were investigated to encompass the practical operating range for the platform concepts. Parametric analysis for the United States and foreign areas was performed to provide a basis for vehicle system design tradeoffs. This analysis of wind magnitudes indicates the feasibility of annual operation at a majority of sites and more selective seasonal operation for the extreme conditions between the pressure altitudes of 100 to 25 mb based upon the assumed design speeds.
The NIST SPIDER, A Robot Crane
Albus, James; Bostelman, Roger; Dagalakis, Nicholas
1992-01-01
The Robot Systems Division of the National Institute of Standards and Technology has been experimenting for several years with new concepts for robot cranes. These concepts utilize the basic idea of the Stewart Platform parallel link manipulator. The unique feature of the NIST approach is to use cables as the parallel links and to use winches as the actuators. So long as the cables are all in tension, the load is kinematically constrained, and the cables resist perturbing forces and moments with equal stiffness to both positive and negative loads. The result is that the suspended load is constrained with a mechanical stiffness determined by the elasticity of the cables, the suspended weight, and the geometry of the mechanism. Based on these concepts, a revolutionary new type of robot crane, the NIST SPIDER (Stewart Platform Instrumented Drive Environmental Robot) has been developed that can control the position, velocity, and force of tools and heavy machinery in all six degrees of freedom (x, y, z, roll, pitch, and yaw). Depending on what is suspended from its work platform, the SPIDER can perform a variety of tasks. Examples are: cutting, excavating and grading, shaping and finishing, lifting and positioning. A 6 m version of the SPIDER has been built and critical performance characteristics analyzed. PMID:28053439
The NIST SPIDER, A Robot Crane.
Albus, James; Bostelman, Roger; Dagalakis, Nicholas
1992-01-01
The Robot Systems Division of the National Institute of Standards and Technology has been experimenting for several years with new concepts for robot cranes. These concepts utilize the basic idea of the Stewart Platform parallel link manipulator. The unique feature of the NIST approach is to use cables as the parallel links and to use winches as the actuators. So long as the cables are all in tension, the load is kinematically constrained, and the cables resist perturbing forces and moments with equal stiffness to both positive and negative loads. The result is that the suspended load is constrained with a mechanical stiffness determined by the elasticity of the cables, the suspended weight, and the geometry of the mechanism. Based on these concepts, a revolutionary new type of robot crane, the NIST SPIDER (Stewart Platform Instrumented Drive Environmental Robot) has been developed that can control the position, velocity, and force of tools and heavy machinery in all six degrees of freedom ( x, y, z , roll, pitch, and yaw). Depending on what is suspended from its work platform, the SPIDER can perform a variety of tasks. Examples are: cutting, excavating and grading, shaping and finishing, lifting and positioning. A 6 m version of the SPIDER has been built and critical performance characteristics analyzed.
Mission demonstration concept for the long-duration storage and transfer of cryogenic propellants
NASA Astrophysics Data System (ADS)
McLean, C.; Deininger, W.; Ingram, K.; Schweickart, R.; Unruh, B.
This paper describes an experimental platform that will demonstrate the major technologies required for the handling and storage of cryogenic propellants in a low-to-zero-g environment. In order to develop a cost-effective, high value-added demonstration mission, a review of the complete mission concept of operations (CONOPS) was performed. The overall cost of such a mission is driven not only by the spacecraft platform and on-orbit experiments themselves, but also by the complexities of handling cryogenic propellants during ground-processing operations. On-orbit storage methodologies were looked at for both passive and active systems. Passive systems rely purely on isolation of the stored propellant from environmental thermal loads, while active cooling employs cryocooler technologies. The benefit trade between active and passive systems is mission-dependent due to the mass, power, and system-level penalties associated with active cooling systems. The experimental platform described in this paper is capable of demonstrating multiple advanced micro-g cryogenic propellant management technologies. In addition to the requirements of demonstrating these technologies, the methodology of propellant transfer must be evaluated. The handling of multiphase liquids in micro-g is discussed using flight-heritage micro-g propellant management device technologies as well as accelerated tank stratification for access to vapor-free or liquid-free propellants. The mission concept presented shows the extensibility of the experimental platform to demonstrate advanced cryogenic components and technologies, propellant transfer methodologies, as well as the validation of thermal and fluidic models, from subscale tankage to an operational architecture.
Industrial Cloud: Toward Inter-enterprise Integration
NASA Astrophysics Data System (ADS)
Wlodarczyk, Tomasz Wiktor; Rong, Chunming; Thorsen, Kari Anne Haaland
Industrial cloud is introduced as a new inter-enterprise integration concept in cloud computing. The characteristics of an industrial cloud are given by its definition and architecture and compared with other general cloud concepts. The concept is then demonstrated by a practical use case, based on Integrated Operations (IO) in the Norwegian Continental Shelf (NCS), showing how industrial digital information integration platform gives competitive advantage to the companies involved. Further research and development challenges are also discussed.
Materials experiment carrier concepts definition study. Volume 2: Technical report, part 2
NASA Technical Reports Server (NTRS)
1981-01-01
A materials experiment carrier (MEC) that provides effective accommodation of the given baseline materials processing in space (MPS) payloads and demonstration of the MPS platform concept for high priority materials processing science, multidiscipline MPS investigations, host carrier for commercial MPS payloads, and system economy of orbital operations is defined. The study flow of task work is shown. Study tasks featured analysis and trades to identify the MEC system concept options.
Development and Validation of a Short-Form Safety Net Medical Home Scale.
Nocon, Robert S; Gunter, Kathryn E; Gao, Yue; Lee, Sang Mee; Chin, Marshall H
2017-12-01
To develop a short-form Safety Net Medical Home Scale (SNMHS) for assessing patient-centered medical home (PCMH) capability in safety net clinics. National surveys of federally qualified health centers (FQHCs). Interviews with FQHC directors. We constructed three short-form SNMHS versions and examined correlations with full SNMHS and related primary care assessments. We tested usability with FQHC directors and reviewed scale development with an advisory group. Federally qualified health center surveys were administered in 2009 and 2013, by mail and online. Usability testing was conducted through telephone interviews with FQHC directors in 2013. Six-, 12-, and 18-question short-form SNMHS versions had Pearson correlations with full scale of 0.84, 0.92, and 0.96, respectively. All versions showed a level of convergent validity with other primary care assessment scales comparable to the full SNMHS. User testers found short forms to be low-burden, though missing some PCMH concepts. Advisory group members expressed caution over missing concepts and appropriate use of short-form self-assessments. Short-form versions of SNMHS showed strong correlations with full scale and may be useful for brief assessment of safety net PCMH capability. Each short-form SNMHS version may be appropriate for different research, quality improvement, and assessment purposes. © Health Research and Educational Trust.
2014-10-06
The nanosheets, like many SERS platforms, are ideally suited for encoding schemes based on the SERS signal from a variety of thiolated small...counterfeiting purposes. The nanosheets, like many SERS platforms, are ideally suited for encoding schemes based on the SERS signal from a variety of...environments ( like the surface of human hair). 2. Nanoflares In 2007, we first introduced the concept of nanoflares. Nanoflares are a new class of
ERIC Educational Resources Information Center
Michalak, Krzysztof
2015-01-01
This paper aims at describing the way in which online translation platforms can facilitate the process of training translators. "Zooniverse," a website hosting a variety of citizen science projects in which everyone can take part, was used as an example of such a concept. The first section of this paper is focused on the history, idea…
2011-06-01
DeLong, W., Yepez, S., Reedy, D. and White, S., “Use of Composite Materials, Health Monitoring and Self Healing Concepts to Refurbish our Civil and...Health Monitoring and Self Healing Concepts to Refurbish Our Civil and Military Infrastructure”, Sandia National Laboratories Report SAND2007-5547...failure without the need for the system to go off-line. Recovery Blocks and Self - Healing (Software) The backwards
Vázquez, Enrique
2017-01-01
Internet of Things platforms for Smart Cities are technologically complex and deploying them at large scale involves high costs and risks. Therefore, pilot schemes that allow validating proof of concepts, experimenting with different technologies and services, and fine-tuning them before migrating them to actual scenarios, are especially important in this context. The IoT platform deployed across the engineering schools of the Universidad Politécnica de Madrid in the Moncloa Campus of International Excellence represents a good example of a test bench for experimentation with Smart City services. This paper presents the main features of this platform, putting special emphasis on the technological challenges faced and on the solutions adopted, as well as on the functionality, services and potential that the platform offers. PMID:29292790
Alvarez-Campana, Manuel; López, Gregorio; Vázquez, Enrique; Villagrá, Víctor A; Berrocal, Julio
2017-12-08
Internet of Things platforms for Smart Cities are technologically complex and deploying them at large scale involves high costs and risks. Therefore, pilot schemes that allow validating proof of concepts, experimenting with different technologies and services, and fine-tuning them before migrating them to actual scenarios, are especially important in this context. The IoT platform deployed across the engineering schools of the Universidad Politécnica de Madrid in the Moncloa Campus of International Excellence represents a good example of a test bench for experimentation with Smart City services. This paper presents the main features of this platform, putting special emphasis on the technological challenges faced and on the solutions adopted, as well as on the functionality, services and potential that the platform offers.
Hydrogenolysis goes bio: from carbohydrates and sugar alcohols to platform chemicals.
Ruppert, Agnieszka M; Weinberg, Kamil; Palkovits, Regina
2012-03-12
In view of the diminishing oil resources and the ongoing climate change, the use of efficient and environmentally benign technologies for the utilization of renewable resources has become indispensible. Therein, hydrogenolysis reactions offer a promising possibility for future biorefinery concepts. These reactions result in the cleavage of C-C and C-O bonds by hydrogen and allow direct access to valuable platform chemicals already integrated in today's value chains. Thus, hydrogenolysis bears the potential to bridge currently available technologies and future biomass-based refinery concepts. This Review highlights past and present developments in this field, with special emphasis on the direct utilization of cellulosic feedstocks. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Concept Study on a Flexible Standard Bus for Small Scientific Satellites
NASA Astrophysics Data System (ADS)
Fukuda, Seisuke; Sawai, Shujiro; Sakai, Shin-Ichiro; Saito, Hirobumi; Tohma, Takayuki; Takahashi, Junko; Toriumi, Tsuyoshi; Kitade, Kenji
In this paper, a new standard bus system for a series of small scientific satellites in the Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency (ISAS/JAXA) is described. Since each mission proposed for the series has a wide variety of requirements, a lot of efforts are needed to enhance flexibility of the standard bus. Some concepts from different viewpoints are proposed. First, standardization layers concerning satellite configuration, instruments, interfaces, and design methods are defined respectively. Methods of product platform engineering, which classify specifications of the bus system into a core platform, alternative variants, and selectable variants, are also investigated in order to realize a semi-custom-made bus. Furthermore, a tradeoff between integration and modularization architecture is fully considered.
Autonomous onboard crew operations: A review and developmental approach
NASA Technical Reports Server (NTRS)
Rogers, J. G.
1982-01-01
A review of the literature generated by an intercenter mission approach and consolidation team and their contractors was performed to obtain background information on the development of autonomous operations concepts for future space shuttle and space platform missions. The Boeing 757/767 flight management system was examined to determine the relevance for transfer of the developmental approach and technology to the performance of the crew operations function. In specific, the engine indications and crew alerting system was studied to determine the relevance of this display for the performance of crew operations onboard the vehicle. It was concluded that the developmental approach and technology utilized in the aeronautics industry would be appropriate for development of an autonomous operations concept for the space platform.
NASA Technical Reports Server (NTRS)
Myers, H. L.
1973-01-01
The programmatic analyses conducted to achieve the objectives of the study are presented. The characteristics are examined of alternate geosynchronous programs based on servicing concepts, geosynchronous platform configurations, and equipment definitions which have evolved during the study. The logistics support necessary to carry out programs using these systems is defined considering alternate approaches for on-orbit servicing. The costs of the resultant programs are then determined and the alternate program approaches compared. Conventional programs with expendable satellites are also defined to the extent necessary to permit comparison with on-orbit serviced platform programs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maestas, J.H.
The Loopback Tester is an Intel SBC 86/12A Single Board Computer and an Intel SBC 534 Communications Expansion Board configured and programmed to perform various basic or less. These tests include: (1) Data Communications Equipment (DCE) transmit timing detection (2) data rate measurement (3) instantaneous loopback indication and (4) bit error rate testing. It requires no initial setup after plug in, and can be used to locate the source of communications loss in a circuit. It can also be used to determine when crypto variable mismatch problems are the source of communications loss. This report discusses the functionality of themore » Loopback Tester as a diagnostic device. It also discusses the hardware and software which implements this simple yet reliable device.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fayomi, O. S. I., E-mail: ojosundayfayomi3@gmail.com; Department of Mechanical Engineering, Covenant University, P.M.B. 1023, Canaanland, Ota; Popoola, A. P. I.
This paper studies effects of the composite particle infringement of ZnO/Cr{sub 2}O{sub 3} on zinc rich ternary based coating. The corrosion-degradation property in 3.5% NaCl was investigatedusing polarization technique. The structural characteristics of the multilayer produce coatings were evaluated by scanning electron microscope (SEM) equipped with an energy dispersive spectrometer (EDS). The mechanical response of the coated samples was studied using a diamond base Dura –Scan) micro-hardness tester and a MTR-300 dry abrasive wear tester. The combined effect of the coatings gave highly-improved performance on microhardness, corrosion and wear damage. This also implies that protection of wind-energy structures in marinemore » environments can be achieved by composite strengthening capacity.« less
Seeding Cracks Using a Fatigue Tester for Accelerated Gear Tooth Breaking
NASA Technical Reports Server (NTRS)
Nenadic, Nenad G.; Wodenscheck, Joseph A.; Thurston, Michael G.; Lewicki, David G.
2011-01-01
This report describes fatigue-induced seeded cracks in spur gears and compares them to cracks created using a more traditional seeding method, notching. Finite element analysis (FEA) compares the effective compliance of a cracked tooth to the effective compliance of a notched tooth where the crack and the notch are of the same depth. In this analysis, cracks are propagated to the desired depth using FRANC2D and effective compliances are computed in ANSYS. A compliance-based feature for detecting cracks on the fatigue tester is described. The initiated cracks are examined using both nondestructive and destructive methods. The destructive examination reveals variability in the shape of crack surfaces.
NASA Astrophysics Data System (ADS)
Lvova, N. A.; Blank, V. D.; Gogolinskiy, K. V.; Kulibaba, V. F.
2007-04-01
Specifisities of deformation on nanoscale of hard brittle materials with the hardness exceeding 10 GP by means of scanning probe microscope - nanohardness tester "NanoScan" are investigated. It is found, that pile-up is forming at scratching of sample surface with use of diamond indenter. Heigh of this pile-up depends on hardness and elastic modulus of the material. Definition of the contact area without taking into account height of pile-up leads to an overestimation of hardness values. At scratching of silicon carbide surface a transition from plastic flow to fracture is found out. The results received allowed to estimate fracture toughness KIC for silicon carbide.
Development of a Portable Torque Wrench Tester
NASA Astrophysics Data System (ADS)
Wang, Y.; Zhang, Q.; Gou, C.; Su, D.
2018-03-01
A portable torque wrench tester (PTWT) with calibration range from 0.5 Nm to 60 Nm has been developed and evaluated for periodic or on-site calibration of setting type torque wrenches, indicating type torque wrenches and hand torque screwdrivers. The PTWT is easy to carry with weight about 10 kg, simple and efficient operation and energy saving with an automatic loading and calibrating system. The relative expanded uncertainty of torque realized by the PTWT was estimated to be 0.8%, with the coverage factor k=2. A comparison experiment has been done between the PTWT and a reference torque standard at our laboratory. The consistency between these two devices under the claimed uncertainties was verified.
Multi-octave spectral beam combiner on ultra-broadband photonic integrated circuit platform.
Stanton, Eric J; Heck, Martijn J R; Bovington, Jock; Spott, Alexander; Bowers, John E
2015-05-04
We present the design of a novel platform that is able to combine optical frequency bands spanning 4.2 octaves from ultraviolet to mid-wave infrared into a single, low M2 output waveguide. We present the design and realization of a key component in this platform that combines the wavelength bands of 350 nm - 1500 nm and 1500 nm - 6500 nm with demonstrated efficiency greater than 90% in near-infrared and mid-wave infrared. The multi-octave spectral beam combiner concept is realized using an integrated platform with silicon nitride waveguides and silicon waveguides. Simulated bandwidth is shown to be over four octaves, and measured bandwidth is shown over two octaves, limited by the availability of sources.
Next generation platforms for high-throughput biodosimetry.
Repin, Mikhail; Turner, Helen C; Garty, Guy; Brenner, David J
2014-06-01
Here the general concept of the combined use of plates and tubes in racks compatible with the American National Standards Institute/the Society for Laboratory Automation and Screening microplate formats as the next generation platforms for increasing the throughput of biodosimetry assays was described. These platforms can be used at different stages of biodosimetry assays starting from blood collection into microtubes organised in standardised racks and ending with the cytogenetic analysis of samples in standardised multiwell and multichannel plates. Robotically friendly platforms can be used for different biodosimetry assays in minimally equipped laboratories and on cost-effective automated universal biotech systems. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Control of intelligent robots in space
NASA Technical Reports Server (NTRS)
Freund, E.; Buehler, CH.
1989-01-01
In view of space activities like International Space Station, Man-Tended-Free-Flyer (MTFF) and free flying platforms, the development of intelligent robotic systems is gaining increasing importance. The range of applications that have to be performed by robotic systems in space includes e.g., the execution of experiments in space laboratories, the service and maintenance of satellites and flying platforms, the support of automatic production processes or the assembly of large network structures. Some of these tasks will require the development of bi-armed or of multiple robotic systems including functional redundancy. For the development of robotic systems which are able to perform this variety of tasks a hierarchically structured modular concept of automation is required. This concept is characterized by high flexibility as well as by automatic specialization to the particular sequence of tasks that have to be performed. On the other hand it has to be designed such that the human operator can influence or guide the system on different levels of control supervision, and decision. This leads to requirements for the hardware and software concept which permit a range of application of the robotic systems from telemanipulation to autonomous operation. The realization of this goal requires strong efforts in the development of new methods, software and hardware concepts, and the integration into an automation concept.
NASA Astrophysics Data System (ADS)
Scott, D. K.; Neilsen, T. L.; Weston, C.; Frazier, C.; Smith, T.; Shumway, A.
2015-12-01
Global measurements of vertically-resolved atmospheric wind profiles offer the potential for improved weather forecasts and superior predictions of atmospheric wind patterns. A small-satellite constellation that uses a Fourier Transform Spectrometer (FTS) instrument onboard 12U CubeSats can provide measurements of global tropospheric wind profiles from space at a very low cost. These small satellites are called FTS CubeSats. This presentation will describe a spacecraft concept that provides a stable, robust platform to host the FTS payload. Of importance to the payload are power, data, station keeping, thermal, and accommodations that enable high spectral measurements to be made from a LEO orbit. The spacecraft concept draws on Space Dynamics Laboratory (SDL) heritage and the recent success of the Dynamic Ionosphere Cubesat Experiment (DICE) and HyperAngular Rainbow Polarimeter (HARP) missions. Working with team members, SDL built a prototype observatory (spacecraft and payload) for testing and proof of concept.
A Multi-Level Parallelization Concept for High-Fidelity Multi-Block Solvers
NASA Technical Reports Server (NTRS)
Hatay, Ferhat F.; Jespersen, Dennis C.; Guruswamy, Guru P.; Rizk, Yehia M.; Byun, Chansup; Gee, Ken; VanDalsem, William R. (Technical Monitor)
1997-01-01
The integration of high-fidelity Computational Fluid Dynamics (CFD) analysis tools with the industrial design process benefits greatly from the robust implementations that are transportable across a wide range of computer architectures. In the present work, a hybrid domain-decomposition and parallelization concept was developed and implemented into the widely-used NASA multi-block Computational Fluid Dynamics (CFD) packages implemented in ENSAERO and OVERFLOW. The new parallel solver concept, PENS (Parallel Euler Navier-Stokes Solver), employs both fine and coarse granularity in data partitioning as well as data coalescing to obtain the desired load-balance characteristics on the available computer platforms. This multi-level parallelism implementation itself introduces no changes to the numerical results, hence the original fidelity of the packages are identically preserved. The present implementation uses the Message Passing Interface (MPI) library for interprocessor message passing and memory accessing. By choosing an appropriate combination of the available partitioning and coalescing capabilities only during the execution stage, the PENS solver becomes adaptable to different computer architectures from shared-memory to distributed-memory platforms with varying degrees of parallelism. The PENS implementation on the IBM SP2 distributed memory environment at the NASA Ames Research Center obtains 85 percent scalable parallel performance using fine-grain partitioning of single-block CFD domains using up to 128 wide computational nodes. Multi-block CFD simulations of complete aircraft simulations achieve 75 percent perfect load-balanced executions using data coalescing and the two levels of parallelism. SGI PowerChallenge, SGI Origin 2000, and a cluster of workstations are the other platforms where the robustness of the implementation is tested. The performance behavior on the other computer platforms with a variety of realistic problems will be included as this on-going study progresses.
NASA Technical Reports Server (NTRS)
Quick, Jason
2009-01-01
The Upper Stage (US) section of the National Aeronautics and Space Administration's (NASA) Ares I rocket will require internal access platforms for maintenance tasks performed by humans inside the vehicle. Tasks will occur during expensive critical path operations at Kennedy Space Center (KSC) including vehicle stacking and launch preparation activities. Platforms must be translated through a small human access hatch, installed in an enclosed worksite environment, support the weight of ground operators and be removed before flight - and their design must minimize additional vehicle mass at attachment points. This paper describes the application of a user-centered conceptual design process and the unique challenges encountered within NASA's systems engineering culture focused on requirements and "heritage hardware". The NASA design team at Marshall Space Flight Center (MSFC) initiated the user-centered design process by studying heritage internal access kits and proposing new design concepts during brainstorming sessions. Simultaneously, they partnered with the Technology Transfer/Innovative Partnerships Program to research inflatable structures and dynamic scaffolding solutions that could enable ground operator access. While this creative, technology-oriented exploration was encouraged by upper management, some design stakeholders consistently opposed ideas utilizing novel, untested equipment. Subsequent collaboration with an engineering consulting firm improved the technical credibility of several options, however, there was continued resistance from team members focused on meeting system requirements with pre-certified hardware. After a six-month idea-generating phase, an intensive six-week effort produced viable design concepts that justified additional vehicle mass while optimizing the human factors of platform installation and use. Although these selected final concepts closely resemble heritage internal access platforms, challenges from the application of the user-centered process provided valuable lessons for improving future collaborative conceptual design efforts.
The Location of Genes Governing Long First Internode of Corn
Troyer, A. F.
1997-01-01
Knowing breeding behavior and cytological location of traits helps breeders. My objective was to locate dominant genes for long first internode of corn (Zea mays L.). I determined that Hopi Indian corn PI213733 (variety Komona) displayed the trait and grew well in the U.S. Corn Belt. I crossed PI213733 to 26 translocation tester stocks in Minnesota inbred A188 background, backcrossed semi-sterile plants carrying the translocation to A188 the next generation, and grew the segregating generation planted in trenches 15 cm deep with ridges of dirt 10 cm high one year, in trenches 25 cm deep the other year and also at normal (6 cm) depth. Emerged plants were classified for semi-sterility or for normal pollen. I concluded from multiple testers for each chromosome arm that dominant genes for long first internode are located (chromosome and region) on 3S, on 6 near the centromere, and on 9S; spurious associations occurred for two testers. Measurement of cell lengths indicated that PI213733 had more cells than A188 both in upper and in lower mesocotyl sections and that lower, older cells elongated sooner. I found a normal-sized kernel with twin embryos that developed two long first internode seedlings indicating that the amount of endosperm did not limit mesocotyl growth. PMID:9093865
Neutral lumbar spine sitting posture in pain-free subjects.
O'Sullivan, Kieran; O'Dea, Patrick; Dankaerts, Wim; O'Sullivan, Peter; Clifford, Amanda; O'Sullivan, Leonard
2010-12-01
Sitting is a common aggravating factor in low back pain (LBP), and re-education of sitting posture is a common aspect of LBP management. However, there is debate regarding what is an optimal sitting posture. This pilot study had 2 aims; to investigate whether pain-free subjects can be reliably positioned in a neutral sitting posture (slight lumbar lordosis and relaxed thorax); and to compare perceptions of neutral sitting posture to habitual sitting posture (HSP). The lower lumbar spine HSP of seventeen pain-free subjects was initially recorded. Subjects then assumed their own subjectively perceived ideal posture (SPIP). Finally, 2 testers independently positioned the subjects into a tester perceived neutral posture (TPNP). The inter-tester reliability of positioning in TPNP was very good (intraclass correlation coefficient (ICC) = 0.91, mean difference = 3% of range of motion). A repeated measures ANOVA revealed that HSP was significantly more flexed than both SPIP and TPNP (p <0.05). There was no significant difference between SPIP and TPNP (p > 0.05). HSP was more kyphotic than all other postures. This study suggests that pain-free subjects can be reliably positioned in a neutral lumbar sitting posture. Further investigation into the role of neutral sitting posture in LBP subjects is warranted. Copyright © 2010 Elsevier Ltd. All rights reserved.
Test verification and design of the bicycle frame parameters
NASA Astrophysics Data System (ADS)
Zhang, Long; Xiang, Zhongxia; Luo, Huan; Tian, Guan
2015-07-01
Research on design of bicycles is concentrated on mechanism and auto appearance design, however few on matches between the bike and the rider. Since unreasonable human-bike relationship leads to both riders' worn-out joints and muscle injuries, the design of bicycles should focus on the matching. In order to find the best position of human-bike system, simulation experiments on riding comfort under different riding postures are done with the lifemode software employed to facilitate the cycling process as well as to obtain the best position and the size function of it. With BP neural network and GA, analyzing simulation data, conducting regression analysis of parameters on different heights and bike frames, the equation of best position of human-bike system is gained at last. In addition, after selecting testers, customized bikes based on testers' height dimensions are produced according to the size function. By analyzing and comparing the experimental data that are collected from testers when riding common bicycles and customized bicycles, it is concluded that customized bicycles are four times even six times as comfortable as common ones. The equation of best position of human-bike system is applied to improve bikes' function, and the new direction on future design of bicycle frame parameters is presented.
Dental pulp neurophysiology: part 2. Current diagnostic tests to assess pulp vitality.
Abd-Elmeguid, Ashraf; Yu, Donald C
2009-03-01
In this second part of our 2-part review, we discuss recent research about pulp tests that determine the vitality of the tooth and clinically accepted pulp testers. A pain response to hot, cold or an electric pulp tester indicates the vitality of only a tooth's pulpal sensory supply; the response does not give any idea about the state of the pulp. Although the sensitivity of these tests is high, when false-positive and false-negative results occur, they may affect the treatment of the tooth. A tooth falsely diagnosed as nonvital with an electric pulp tester may undergo an unnecessary root canal, whereas one falsely diagnosed as vital may be left untreated, causing the necrotic tissue to destroy the supporting tissues (resorption). The vascular supply is more important to the determination of the health of the pulp than the sensory supply. Pulp death is caused by cessation of blood flow and may result in a necrotic pulp, even though the pulpal sensory supply may still be viable. The pulp can be healed only if the circulating blood flow is healthy. Although still under investigation, diagnostic devices that examine pulpal blood flow, such as the pulse oximeter and laser Doppler flowmetry, show promising results for the assessment of pulp vitality.
Feasibility of Floating Platform Systems for Wind Turbines: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Musial, W.; Butterfield, S.; Boone, A.
This paper provides a general technical description of several types of floating platforms for wind turbines. Platform topologies are classified into multiple- or single-turbine floaters and by mooring method. Platforms using catenary mooring systems are contrasted to vertical mooring systems and the advantages and disadvantages are discussed. Specific anchor types are described in detail. A rough cost comparison is performed for two different platform architectures using a generic 5-MW wind turbine. One platform is a Dutch study of a tri-floater platform using a catenary mooring system, and the other is a mono-column tension-leg platform developed at the National Renewable Energymore » Laboratory. Cost estimates showed that single unit production cost is $7.1 M for the Dutch tri-floater, and $6.5 M for the NREL TLP concept. However, value engineering, multiple unit series production, and platform/turbine system optimization can lower the unit platform costs to $4.26 M and $2.88 M, respectively, with significant potential to reduce cost further with system optimization. These foundation costs are within the range necessary to bring the cost of energy down to the DOE target range of $0.05/kWh for large-scale deployment of offshore floating wind turbines.« less
Sharing Health Big Data for Research - A Design by Use Cases: The INSHARE Platform Approach.
Bouzillé, Guillaume; Westerlynck, Richard; Defossez, Gautier; Bouslimi, Dalel; Bayat, Sahar; Riou, Christine; Busnel, Yann; Le Guillou, Clara; Cauvin, Jean-Michel; Jacquelinet, Christian; Pladys, Patrick; Oger, Emmanuel; Stindel, Eric; Ingrand, Pierre; Coatrieux, Gouenou; Cuggia, Marc
2017-01-01
Sharing and exploiting Health Big Data (HBD) allow tackling challenges: data protection/governance taking into account legal, ethical, and deontological aspects enables trust, transparent and win-win relationship between researchers, citizens, and data providers. Lack of interoperability: compartmentalized and syntactically/semantica heterogeneous data. INSHARE project using experimental proof of concept explores how recent technologies overcome such issues. Using 6 data providers, platform is designed via 3 steps to: (1) analyze use cases, needs, and requirements; (2) define data sharing governance, secure access to platform; and (3) define platform specifications. Three use cases - from 5 studies and 11 data sources - were analyzed for platform design. Governance derived from SCANNER model was adapted to data sharing. Platform architecture integrates: data repository and hosting, semantic integration services, data processing, aggregate computing, data quality and integrity monitoring, Id linking, multisource query builder, visualization and data export services, data governance, study management service and security including data watermarking.
2011-07-27
Ion Battery Packs Advanced Chemistry Batteries EM Armor Power Brick 8 UNCLASSIFIED Concepts Platform Simulation Component Development Vehicle...Advanced Turbocharging, Supercharging, OPOC Efficient Powertrain Technologies Electrified Accessories Energy Harvesting SiC Electronics Lithium
Janjua, Naveed Zafar; Kuo, Margot; Chong, Mei; Yu, Amanda; Alvarez, Maria; Cook, Darrel; Armour, Rosemary; Aiken, Ciaran; Li, Karen; Mussavi Rizi, Seyed Ali; Woods, Ryan; Godfrey, David; Wong, Jason; Gilbert, Mark; Tyndall, Mark W.; Krajden, Mel
2016-01-01
Background The British Columbia (BC) Hepatitis Testers Cohort (BC-HTC) was established to assess and monitor hepatitis C (HCV) epidemiology, cost of illness and treatment effectiveness in BC, Canada. In this paper, we describe the cohort construction, data linkage process, linkage yields, and comparison of the characteristics of linked and unlinked individuals. Methods The BC-HTC includes all individuals tested for HCV and/or HIV or reported as a case of HCV, hepatitis B (HBV), HIV or active tuberculosis (TB) in BC linked with the provincial health insurance client roster, medical visits, hospitalizations, drug prescriptions, the cancer registry and mortality data using unique personal health numbers. The cohort includes data since inception (1990/1992) of each database until 2012/2013 with plans for annual updates. We computed linkage rates by year and compared the characteristics of linked and unlinked individuals. Results Of 2,656,323 unique individuals available in the laboratory and surveillance data, 1,427,917(54%) were included in the final linked cohort, including about 1.15 million tested for HCV and about 1.02 million tested for HIV. The linkage rate was 86% for HCV tests, 89% for HCV cases, 95% for active TB cases, 48% for HIV tests and 36% for HIV cases. Linkage rates increased from 40% for HCV negatives and 70% for HCV positives in 1992 to ~90% after 2005. Linkage rates were lower for males, younger age at testing, and those with unknown residence location. Linkage rates for HCV testers co-infected with HIV, HBV or TB were very high (90–100%). Conclusion Linkage rates increased over time related to improvements in completeness of identifiers in laboratory, surveillance, and registry databases. Linkage rates were higher for HCV than HIV testers, those testing positive, older individuals, and females. Data from the cohort provide essential information to support the development of prevention, care and treatment initiatives for those infected with HCV. PMID:26954020
A Double-Primary Dead-Weight Tester for Pressures (35-175) kPa in Gage Mode.
Jain, Kamlesh; Cen, Yueqin; Bowers, Walter J; Schmidt, James W
2003-01-01
Primary pressure standards in the atmospheric pressure range are often established using mercury manometers. Less frequently, controlled-clearance dead-weight testers in which one component (normally the piston) has been dimensionally measured have also been used. Recent advances in technology on two fronts i) the fabrication of large-diameter pistons and cylinders with good geometry; and ii) the ability to measure the dimensions of these components, have allowed some dead-weight testers at NIST to approach total relative uncertainties (k = 2) in dimensionally-derived effective areas near 5 × 10(-6). This paper describes a single piston/cylinder assembly (NIST-PG201WC/WC) that serves as both a primary gage in which both piston and cylinder are measured dimensionally and a controlled-clearance primary gage (employing the Heydemann-Welch method). Thus it allows some previous assumptions about the modeling of dead-weight testers to be checked. For the gage described in this paper the piston/cylinder clearance obtained from the two analyses have relative differences of 4 × 10(-6) to 7 × 10(-6) over the pressure range 35 kPa to 175 kPa. Some implications of these results will be discussed. From the dimensional characterizations and auxiliary measurements we have determined that the effective area for this gauge at 20 °C is: [Formula: see text]where P is the system pressure and P J is a control pressure. The estimated relative uncertainty in effective area is 8.2 × 10(-6) +1.4 × 10(-11) P/Pa (k = 2). The temperature coefficient for the area was measured and found to be (9.06 ± 0.04) × 10(-6)/K. Thus using the gage at a reference temperature of 23 °C yields an effective area: [Formula: see text]with almost no increase in the uncertainty over that at 20 °C.
Optimal filter bandwidth for pulse oximetry
NASA Astrophysics Data System (ADS)
Stuban, Norbert; Niwayama, Masatsugu
2012-10-01
Pulse oximeters contain one or more signal filtering stages between the photodiode and microcontroller. These filters are responsible for removing the noise while retaining the useful frequency components of the signal, thus improving the signal-to-noise ratio. The corner frequencies of these filters affect not only the noise level, but also the shape of the pulse signal. Narrow filter bandwidth effectively suppresses the noise; however, at the same time, it distorts the useful signal components by decreasing the harmonic content. In this paper, we investigated the influence of the filter bandwidth on the accuracy of pulse oximeters. We used a pulse oximeter tester device to produce stable, repetitive pulse waves with digitally adjustable R ratio and heart rate. We built a pulse oximeter and attached it to the tester device. The pulse oximeter digitized the current of its photodiode directly, without any analog signal conditioning. We varied the corner frequency of the low-pass filter in the pulse oximeter in the range of 0.66-15 Hz by software. For the tester device, the R ratio was set to R = 1.00, and the R ratio deviation measured by the pulse oximeter was monitored as a function of the corner frequency of the low-pass filter. The results revealed that lowering the corner frequency of the low-pass filter did not decrease the accuracy of the oxygen level measurements. The lowest possible value of the corner frequency of the low-pass filter is the fundamental frequency of the pulse signal. We concluded that the harmonics of the pulse signal do not contribute to the accuracy of pulse oximetry. The results achieved by the pulse oximeter tester were verified by human experiments, performed on five healthy subjects. The results of the human measurements confirmed that filtering out the harmonics of the pulse signal does not degrade the accuracy of pulse oximetry.
Romero-Franco, Natalia; Montaño-Munuera, Juan Antonio; Fernández-Domínguez, Juan Carlos; Jiménez-Reyes, Pedro
2017-12-18
New methods are being validated to easily evaluate the knee joint position sense (JPS) due to its role in sports movement and the risk of injury. However, no studies to date have considered the open kinetic chain (OKC) technique, despite the biomechanical differences compared to closed kinetic chain movements. To analyze the validity and reliability of a digital inclinometer to measure the knee JPS in the OKC movement. The validity, inter-tester and intra-tester reliability of a digital inclinometer for measuring knee JPS were evaluated. Sports research laboratory. Eighteen athletes (11 males and 7 females; 28.4 ± 6.6 years; 71.9 ± 14.0 kg; 1.77 ± 0.09 m; 22.8 ± 3.2 kg/m 2 ) voluntary participated in this study. Absolute angular error (AAE), relative angular error (RAE) and variable angular error (VAE) of knee JPS in an OKC. Intraclass correlation coefficient (ICC) and standard error of the mean (SEM) were calculated to determine the validity and reliability of the inclinometer. Data showed excellent validity of the inclinometer to obtain proprioceptive errors compared to the video analysis in JPS tasks (AAE: ICC = 0.981, SEM = 0.08; RAE: ICC = 0.974, SEM = 0.12; VAE: ICC = 0.973, SEM = 0.07). Inter-tester reliability was also excellent for all the proprioceptive errors (AAE: ICC = 0.967, SEM = 0.04; RAE: ICC = 0.974, SEM = 0.03; VAE: ICC = 0.939, SEM = 0.08). Similar results were obtained for intra-tester reliability (AAE: ICC = 0.861, SEM = 0.1; RAE: ICC = 0.894, SEM = 0.1; VAE: ICC = 0.700, SEM = 0.2). The digital inclinometer is a valid and reliable method to assess the knee JPS in OKC. Sport professionals may evaluate the knee JPS to monitor its deterioration during training or improvements throughout the rehabilitation process.
Why the Wait? Delayed HIV Diagnosis among Men Who Have Sex with Men
Thiede, Hanne; Hawes, Stephen E.; Golden, Matthew R.; Hutcheson, Rebecca; Carey, James W.; Kurth, Ann; Jenkins, Richard A.
2010-01-01
We sought to identify factors associated with delayed diagnosis of human immunodeficiency virus (HIV; testing HIV-seropositive 6 months or more after HIV seroconversion), by comparing delayed testers to non-delayed testers (persons who were diagnosed within 6 months of HIV seroconversion), in King County, Washington among men who have sex with men (MSM). Participants were recruited from HIV testing sites in the Seattle area. Delayed testing status was determined by the Serologic Testing Algorithm for Recent HIV Seroconversion or a self-reported previous HIV-negative test. Quantitative data on sociodemographic characteristics, health history, and drug-use and sexual behaviors were collected via computer-assisted self-interviews. Qualitative semi-structured interviews regarding testing and risk behaviors were also conducted. Multivariate analysis was used to identify factors associated with delayed diagnosis. Content analysis was used to establish themes in the qualitative data. Out of the 77 HIV-seropositive MSM in this sample, 39 (51%) had evidence of delayed diagnosis. Factors associated with delayed testing included being African-American, homeless, “out” to 50% or less people about male-male sex, and having only one sex partner in the past 6 months. Delayed testers often cited HIV-related sickness as their reason for testing and fear and wanting to be in denial of their HIV status as reasons for not testing. Delayed testers frequently did not identify as part of the MSM community, did not recognize that they were at risk for HIV acquisition, and did not feel a responsibility to themselves or others to disclose their HIV status. This study illustrates the need to further explore circumstances around delayed diagnosis in MSM and develop outreach methods and prevention messages targeted specifically to this potentially highly marginalized population in order to detect HIV infections earlier, provide HIV care, and prevent new infections. PMID:20186493
Janjua, Naveed Zafar; Kuo, Margot; Chong, Mei; Yu, Amanda; Alvarez, Maria; Cook, Darrel; Armour, Rosemary; Aiken, Ciaran; Li, Karen; Mussavi Rizi, Seyed Ali; Woods, Ryan; Godfrey, David; Wong, Jason; Gilbert, Mark; Tyndall, Mark W; Krajden, Mel
2016-01-01
The British Columbia (BC) Hepatitis Testers Cohort (BC-HTC) was established to assess and monitor hepatitis C (HCV) epidemiology, cost of illness and treatment effectiveness in BC, Canada. In this paper, we describe the cohort construction, data linkage process, linkage yields, and comparison of the characteristics of linked and unlinked individuals. The BC-HTC includes all individuals tested for HCV and/or HIV or reported as a case of HCV, hepatitis B (HBV), HIV or active tuberculosis (TB) in BC linked with the provincial health insurance client roster, medical visits, hospitalizations, drug prescriptions, the cancer registry and mortality data using unique personal health numbers. The cohort includes data since inception (1990/1992) of each database until 2012/2013 with plans for annual updates. We computed linkage rates by year and compared the characteristics of linked and unlinked individuals. Of 2,656,323 unique individuals available in the laboratory and surveillance data, 1,427,917(54%) were included in the final linked cohort, including about 1.15 million tested for HCV and about 1.02 million tested for HIV. The linkage rate was 86% for HCV tests, 89% for HCV cases, 95% for active TB cases, 48% for HIV tests and 36% for HIV cases. Linkage rates increased from 40% for HCV negatives and 70% for HCV positives in 1992 to ~90% after 2005. Linkage rates were lower for males, younger age at testing, and those with unknown residence location. Linkage rates for HCV testers co-infected with HIV, HBV or TB were very high (90-100%). Linkage rates increased over time related to improvements in completeness of identifiers in laboratory, surveillance, and registry databases. Linkage rates were higher for HCV than HIV testers, those testing positive, older individuals, and females. Data from the cohort provide essential information to support the development of prevention, care and treatment initiatives for those infected with HCV.
Optimal filter bandwidth for pulse oximetry.
Stuban, Norbert; Niwayama, Masatsugu
2012-10-01
Pulse oximeters contain one or more signal filtering stages between the photodiode and microcontroller. These filters are responsible for removing the noise while retaining the useful frequency components of the signal, thus improving the signal-to-noise ratio. The corner frequencies of these filters affect not only the noise level, but also the shape of the pulse signal. Narrow filter bandwidth effectively suppresses the noise; however, at the same time, it distorts the useful signal components by decreasing the harmonic content. In this paper, we investigated the influence of the filter bandwidth on the accuracy of pulse oximeters. We used a pulse oximeter tester device to produce stable, repetitive pulse waves with digitally adjustable R ratio and heart rate. We built a pulse oximeter and attached it to the tester device. The pulse oximeter digitized the current of its photodiode directly, without any analog signal conditioning. We varied the corner frequency of the low-pass filter in the pulse oximeter in the range of 0.66-15 Hz by software. For the tester device, the R ratio was set to R = 1.00, and the R ratio deviation measured by the pulse oximeter was monitored as a function of the corner frequency of the low-pass filter. The results revealed that lowering the corner frequency of the low-pass filter did not decrease the accuracy of the oxygen level measurements. The lowest possible value of the corner frequency of the low-pass filter is the fundamental frequency of the pulse signal. We concluded that the harmonics of the pulse signal do not contribute to the accuracy of pulse oximetry. The results achieved by the pulse oximeter tester were verified by human experiments, performed on five healthy subjects. The results of the human measurements confirmed that filtering out the harmonics of the pulse signal does not degrade the accuracy of pulse oximetry.
Cell-Based Genotoxicity Testing
NASA Astrophysics Data System (ADS)
Reifferscheid, Georg; Buchinger, Sebastian
Genotoxicity test systems that are based on bacteria display an important role in the detection and assessment of DNA damaging chemicals. They belong to the basic line of test systems due to their easy realization, rapidness, broad applicability, high sensitivity and good reproducibility. Since the development of the Salmonella microsomal mutagenicity assay by Ames and coworkers in the early 1970s, significant development in bacterial genotoxicity assays was achieved and is still a subject matter of research. The basic principle of the mutagenicity assay is a reversion of a growth inhibited bacterial strain, e.g., due to auxotrophy, back to a fast growing phenotype (regain of prototrophy). Deeper knowledge of the mutation events allows a mechanistic understanding of the induced DNA-damage by the utilization of base specific tester strains. Collections of such specific tester strains were extended by genetic engineering. Beside the reversion assays, test systems utilizing the bacterial SOS-response were invented. These methods are based on the fusion of various SOS-responsive promoters with a broad variety of reporter genes facilitating numerous methods of signal detection. A very important aspect of genotoxicity testing is the bioactivation of xenobiotics to DNA-damaging compounds. Most widely used is the extracellular metabolic activation by making use of rodent liver homogenates. Again, genetic engineering allows the construction of highly sophisticated bacterial tester strains with significantly enhanced sensitivity due to overexpression of enzymes that are involved in the metabolism of xenobiotics. This provides mechanistic insights into the toxification and detoxification pathways of xenobiotics and helps explaining the chemical nature of hazardous substances in unknown mixtures. In summary, beginning with "natural" tester strains the rational design of bacteria led to highly specific and sensitive tools for a rapid, reliable and cost effective genotoxicity testing that is of outstanding importance in the risk assessment of compounds (REACH) and in ecotoxicology.
Development of FEB Test Platform for ATLAS New Small Wheel Upgrade
NASA Astrophysics Data System (ADS)
Lu, Houbing; Hu, Kun; Wang, Xu; Li, Feng; Han, Liang; Jin, Ge
2016-10-01
This concept of test platform is based on the test requirements of the front-end board (FEB) which is developed for the phase I upgrade of the small Thin Gap Chamber(sTGC) detector on New Small Wheel(NSW) of ATLAS. The front-end electronics system of sTGC consists of 1,536 FEBs with about 322,000 readout of strips, wires and pads in total. A test platform for FEB with up to 256 channels has been designed to keep the testing efficiency at a controllable level. We present the circuit model architecture of the platform, and its functions and implementation as well. The firmware based on Field Programmable Gate Array (FPGA) and the software based on PC have been developed, and basic test methods have been established. FEB readout measurements have been performed in analog injection from the test platform, which will provide a fast and efficient test method for the production of FEB.
Efficient Energy-Storage Concept
NASA Technical Reports Server (NTRS)
Brantley, L. W. J.; Rupp, C.
1982-01-01
Space-platform energy-storage and attitude-stabilization system utilizes variable moment of inertia of two masses attached to ends of retractable cable. System would be brought to its initial operating speed by gravity-gradient pumping. When fully developed, concept could be part of an orbiting solar-energy collection system. Energy would be temporarily stored in system then transmitted to Earth by microwaves or other method.
Space Experiment Concepts: Cup-Burner Flame Extinguishment
NASA Technical Reports Server (NTRS)
Takahashi, Fumiaki
2004-01-01
Space Fire Suppression Processes & Technology. Space experiment concepts of cup-burner flame extinguishment have been conceived to address to the key issues (i.e., organizing questions) in space fire suppression. Cup-burner flame extinguishment experiment can reveal physical and chemical suppression processes and provide agent effectiveness data useful for technology development of space fire suppression systems in various reduced-gravity platforms.
2011-06-01
des performances clés et modélisation de la disponibilité avion. • Concepts et technologies de gestion de la maintenance/ du soutien pour...l’utilisation des concepts de maintenance et des technologies avancées pour améliorer la disponibilité des aéronefs et réduire le coût du cycle de vie. L’équipe...aériennes. Dans la ligne du travail fourni par la commission AVT, un atelier
Context management platform for tourism applications.
Buján, David; Martín, David; Torices, Ortzi; López-de-Ipiña, Diego; Lamsfus, Carlos; Abaitua, Joseba; Alzua-Sorzabal, Aurkene
2013-06-24
The notion of context has been widely studied and there are several authors that have proposed different definitions of context. However, context has not been widely studied in the framework of human mobility and the notion of context has been imported directly from other computing fields without specifically addressing the tourism domain requirements. In order to store and manage context information a context data model and a context management platform are needed. Ontologies have been widely used in context modelling, but many of them are designed to be applied in general ubiquitous computing environments, do not contain specific concepts related to the tourism domain or some approaches do not contain enough concepts to represent context information related to the visitor on the move. That is why we propose a new approach to provide a better solution to model context data in tourism environments, adding more value to our solution reusing data about tourist resources from an Open Data repository and publishing it as Linked Data. We also propose the architecture for a context information management platform based on this context data model.
Advances in microfluidics for drug discovery.
Lombardi, Dario; Dittrich, Petra S
2010-11-01
Microfluidics is considered as an enabling technology for the development of unconventional and innovative methods in the drug discovery process. The concept of micrometer-sized reaction systems in the form of continuous flow reactors, microdroplets or microchambers is intriguing, and the versatility of the technology perfectly fits with the requirements of drug synthesis, drug screening and drug testing. In this review article, we introduce key microfluidic approaches to the drug discovery process, highlighting the latest and promising achievements in this field, mainly from the years 2007 - 2010. Despite high expectations of microfluidic approaches to several stages of the drug discovery process, up to now microfluidic technology has not been able to significantly replace conventional drug discovery platforms. Our aim is to identify bottlenecks that have impeded the transfer of microfluidics into routine platforms for drug discovery and show some recent solutions to overcome these hurdles. Although most microfluidic approaches are still applied only for proof-of-concept studies, thanks to creative microfluidic research in the past years unprecedented novel capabilities of microdevices could be demonstrated, and general applicable, robust and reliable microfluidic platforms seem to be within reach.
Context Management Platform for Tourism Applications
Buján, David; Martín, David; Torices, Ortzi; López-de-Ipiña, Diego; Lamsfus, Carlos; Abaitua, Joseba; Alzua-Sorzabal, Aurkene
2013-01-01
The notion of context has been widely studied and there are several authors that have proposed different definitions of context. However, context has not been widely studied in the framework of human mobility and the notion of context has been imported directly from other computing fields without specifically addressing the tourism domain requirements. In order to store and manage context information a context data model and a context management platform are needed. Ontologies have been widely used in context modelling, but many of them are designed to be applied in general ubiquitous computing environments, do not contain specific concepts related to the tourism domain or some approaches do not contain enough concepts to represent context information related to the visitor on the move. That is why we propose a new approach to provide a better solution to model context data in tourism environments, adding more value to our solution reusing data about tourist resources from an Open Data repository and publishing it as Linked Data. We also propose the architecture for a context information management platform based on this context data model. PMID:23797739
Linear thermal circulator based on Coriolis forces.
Li, Huanan; Kottos, Tsampikos
2015-02-01
We show that the presence of a Coriolis force in a rotating linear lattice imposes a nonreciprocal propagation of the phononic heat carriers. Using this effect we propose the concept of Coriolis linear thermal circulator which can control the circulation of a heat current. A simple model of three coupled harmonic masses on a rotating platform permits us to demonstrate giant circulating rectification effects for moderate values of the angular velocities of the platform.
NASA Technical Reports Server (NTRS)
Anderson, Brian L.
1993-01-01
The development of the Control Center Complex (CCC), a synergistic control center supporting both the Space Station Freedom and the Space Shuttle Program, is described. To provide maximum growth and flexibility, the CCC uses commercial off-the-shelf technology and industry standards. The discussion covers the development philosophy, CCC architecture, data distribution, the software platform concept, workstation platform, commercial tools for the CCC, and benefits of synergy.
Construction of Multimodal Transport Information Platform
NASA Astrophysics Data System (ADS)
Wang, Ya; Cheng, Yu; Zhao, Zhi
2018-06-01
With the rapid development of economy, the volume of transportation in China is increasing, the opening process of the market is accelerating, the scale of enterprises is expanding, the service quality is being improved, and the container multimodal transport is developing continuously.The hardware infrastructure of container multimodal transport is improved obviously, but the network platform construction of multimodal transport is still insufficient.Taking Shandong region of China as an example, the present situation of container multimodal transport in Shandong area can no longer meet the requirement of rapid development of container, and the construction of network platform needs to be solved urgently. Therefore, this paper will briefly describe the conception of construction of multimodal transport network platform in Shandong area.In order to achieve the rapid development of multimodal transport.
Communication Platform Payload Definition (CPPD) study. Volume 2: Technical report
NASA Technical Reports Server (NTRS)
Hunter, E. M.; Driggers, T.; Jorasch, R.
1986-01-01
This is Volume 2 (Technical Report) of the Ford Aerospace & Communications Corporation Final Report for the Communication Platform Payload Definition (CPPD) Study program conducted for NASA Lewis Research Center under contract No. NAS3-24235. This report presents the results of the study effort leading to five potential platform payloads to service CONUS and WARC Region 2 traffic demand as projected to the year 2008. The report addresses establishing the data bases, developing service aggregation scenarios, selecting and developing 5 payload concepts, performing detailed definition of the 5 payloads, costing them, identifying critical technology, and finally comparing the payloads with each other and also with non-aggregated equivalent services.
NASA Astrophysics Data System (ADS)
Cao, Xuesong; Jiang, Ling; Hu, Ruimin
2006-10-01
Currently, the applications of surveillance system have been increasingly widespread. But there are few surveillance platforms that can meet the requirement of large-scale, cross-regional, and flexible surveillance business. In the paper, we present a distributed surveillance system platform to improve safety and security of the society. The system is constructed by an object-oriented middleware called as Internet Communications Engine (ICE). This middleware helps our platform to integrate a lot of surveillance resource of the society and accommodate diverse range of surveillance industry requirements. In the follow sections, we will describe in detail the design concepts of system and introduce traits of ICE.
Communication Platform Payload Definition (CPPD) study. Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
Hunter, E. M.
1986-01-01
This is Volume 1 (Executive Summary) of the Ford Aerospace & Communications Corporation Final Report for the Communication Platform Payload Definition (CPPD) Study program conducted for NASA Lewis Research Center under contract No. NAS3-24235. This report presents the results of the study effort leading to five potential platform payloads to service CONUS and WARC Region 2 traffic demand as projected to the year 2008. The report addresses establishing the data bases, developing service aggregation scenarios, selecting and developing 5 payload concepts, performing detailed definition of the 5 payloads, costing them, identifying critical technology, and finally comparing the payloads with each other and also with non-aggregated equivalent services.
NASA Technical Reports Server (NTRS)
Rieker, Lorra L.; Haraburda, Francis M.
1989-01-01
Information is presented on how the concept of commonality is being implemented with respect to electric power system hardware for the Space Station Freedom and the U.S. Polar Platform. Included is a historical account of the candidate common items which have the potential to serve the same power system functions on both Freedom and the Polar Platform. The Space Station program and objectives are described, focusing on the test and development responsibilities. The program definition and preliminary design phase and the design and development phase are discussed. The goal of this work is to reduce the program cost.
Communication Platform Payload Definition (CPPD) study. Volume 3: Addendum
NASA Technical Reports Server (NTRS)
Hunter, E. M.; Driggers, T.; Jorasch, R.
1986-01-01
This is Volume 3 (Addendum) of the Ford Aerospace & Communications Corporation Final Report for the Communication Platform Payload Definition (CPPD) Study Program conducted for NASA Lewis Research Center under contract No. NAS3-24235. This report presents the results of the study effort leading to five potential platform payloads to service CONUS and WARC Region 2 traffic demand as projected to the year 2008. The report addresses establishing the data bases, developing service aggregation scenarios, selecting and developing 5 payload concepts, performing detailed definition of the 5 payloads, costing them, identifying critical technology, and finally comparing the payloads with each other and also with non-aggregated equivalent services.
Biomimetic High Density Lipoprotein Nanoparticles For Nucleic Acid Delivery
McMahon, Kaylin M.; Mutharasan, R. Kannan; Tripathy, Sushant; Veliceasa, Dorina; Bobeica, Mariana; Shumaker, Dale K.; Luthi, Andrea J.; Helfand, Brian T.; Ardehali, Hossein; Mirkin, Chad A.; Volpert, Olga; Thaxton, C. Shad
2014-01-01
We report a gold nanoparticle-templated high density lipoprotein (HDL AuNP) platform for gene therapy which combines lipid-based nucleic acid transfection strategies with HDL biomimicry. For proof-of-concept, HDL AuNPs are shown to adsorb antisense cholesterylated DNA. The conjugates are internalized by human cells, can be tracked within cells using transmission electron microscopy (TEM), and regulate target gene expression. Overall, the ability to directly image the AuNP core within cells, the chemical tailorability of the HDL AuNP platform, and the potential for cell-specific targeting afforded by HDL biomimicry make this platform appealing for nucleic acid delivery. PMID:21319839
Heat flux measurement in SSME turbine blade tester
NASA Astrophysics Data System (ADS)
Liebert, Curt H.
1990-11-01
Surface heat flux values were measured in the turbine blade thermal cycling tester located at NASA-Marshall. This is the first time heat flux has been measured in a space shuttle main engine turbopump environment. Plots of transient and quasi-steady state heat flux data over a range of about 0 to 15 MW/sq m are presented. Data were obtained with a miniature heat flux gage device developed at NASA-Lewis. The results from these tests are being incorporated into turbine design models. Also, these gages are being considered for airfoil surface heat flux measurement on turbine vanes mounted in SSME turbopump test bed engine nozzles at Marshall. Heat flux effects that might be observed on degraded vanes are discussed.
Heat flux measurement in SSME turbine blade tester
NASA Astrophysics Data System (ADS)
Liebert, Curt H.
Surface heat flux values were measured in the turbine blade thermal cycling tester located at NASA-Marshall. This is the first time heat flux has been measured in a space shuttle main engine turbopump environment. Plots of transient and quasi-steady state heat flux data over a range of about 0 to 15 MW/sq m are presented. Data were obtained with a miniature heat flux gage device developed at NASA-Lewis. The results from these tests are being incorporated into turbine design models. Also, these gages are being considered for airfoil surface heat flux measurement on turbine vanes mounted in SSME turbopump test bed engine nozzles at Marshall. Heat flux effects that might be observed on degraded vanes are discussed.
Zhang, Lei; Lu, Jin-Zhong; Zhang, Yong-Kang; Ma, Hai-Le; Luo, Kai-Yu; Dai, Feng-Ze
2017-01-01
Effects of laser shock processing (LSP) on the cavitation erosion resistance of laser weldments were investigated by optical microscope (OM), scanning electron microscope (SEM) observations, roughness tester, micro hardness tester, and X-ray diffraction (XRD) technology. The morphological microstructures were characterized. Cumulative mass loss, incubation period, erosion rate, and damaged surface areas were monitored during cavitation erosion. Surface roughness, micro-hardness, and residual stress were measured in different zones. Results showed that LSP could improve the damage of morphological microstructures and mechanical properties after cavitation erosion. The compressive residual stresses were generated during the process of LSP, which was an effective guarantee for the improvement of the above mentioned properties. PMID:28772652
Albin, Aaron; Ji, Xiaonan; Borlawsky, Tara B; Ye, Zhan; Lin, Simon; Payne, Philip Ro; Huang, Kun; Xiang, Yang
2014-10-07
The Unified Medical Language System (UMLS) contains many important ontologies in which terms are connected by semantic relations. For many studies on the relationships between biomedical concepts, the use of transitively associated information from ontologies and the UMLS has been shown to be effective. Although there are a few tools and methods available for extracting transitive relationships from the UMLS, they usually have major restrictions on the length of transitive relations or on the number of data sources. Our goal was to design an efficient online platform that enables efficient studies on the conceptual relationships between any medical terms. To overcome the restrictions of available methods and to facilitate studies on the conceptual relationships between medical terms, we developed a Web platform, onGrid, that supports efficient transitive queries and conceptual relationship studies using the UMLS. This framework uses the latest technique in converting natural language queries into UMLS concepts, performs efficient transitive queries, and visualizes the result paths. It also dynamically builds a relationship matrix for two sets of input biomedical terms. We are thus able to perform effective studies on conceptual relationships between medical terms based on their relationship matrix. The advantage of onGrid is that it can be applied to study any two sets of biomedical concept relations and the relations within one set of biomedical concepts. We use onGrid to study the disease-disease relationships in the Online Mendelian Inheritance in Man (OMIM). By crossvalidating our results with an external database, the Comparative Toxicogenomics Database (CTD), we demonstrated that onGrid is effective for the study of conceptual relationships between medical terms. onGrid is an efficient tool for querying the UMLS for transitive relations, studying the relationship between medical terms, and generating hypotheses.
ERIC Educational Resources Information Center
Charitonos, Koula; Charalampidi, Marina; Scanlon, Eileen
2016-01-01
Heritage language education is distinct from the field of second language acquisition due to having the concept of identity always at its core (Leeman, Rabin, & Roman-Mendoza, 2012). This paper draws on this concept and presents an action research study focusing on the teaching and learning of Greek as a heritage language in the context of…
GRC RBCC Concept Multidisciplinary Analysis
NASA Technical Reports Server (NTRS)
Suresh, Ambady
2001-01-01
This report outlines the GRC RBCC Concept for Multidisciplinary Analysis. The multidisciplinary coupling procedure is presented, along with technique validations and axisymmetric multidisciplinary inlet and structural results. The NPSS (Numerical Propulsion System Simulation) test bed developments and code parallelization are also presented. These include milestones and accomplishments, a discussion of running R4 fan application on the PII cluster as compared to other platforms, and the National Combustor Code speedup.
2016-02-16
into areas where there is no access to maritime platforms. Sea-based interceptor platforms have the ability to intercept targets at each stage of the...argues that the most efficient concept for integrating active defense weapon systems is a multi- layered architecture with redundant intercept ...faster data transfer and will prevent data loss. The need for almost 100% interception successes is increasing as the threat becomes more
DOE Office of Scientific and Technical Information (OSTI.GOV)
Polly, Benjamin J
This presentation shows how NREL is approaching Zero Energy Districts, including key opportunities, design strategies, and master planning concepts. The presentation also covers URBANopt, an advanced analytical platform for district that is being developed by NREL.
Kindgen, Sarah; Wachtel, Herbert; Abrahamsson, Bertil; Langguth, Peter
2015-09-01
Disintegration of oral solid dosage forms is a prerequisite for drug dissolution and absorption and is to a large extent dependent on the pressures and hydrodynamic conditions in the solution that the dosage form is exposed to. In this work, the hydrodynamics in the PhEur/USP disintegration tester were investigated using computational fluid dynamics (CFD). Particle image velocimetry was used to validate the CFD predictions. The CFD simulations were performed with different Newtonian and non-Newtonian fluids, representing fasted and fed states. The results indicate that the current design and operating conditions of the disintegration test device, given by the pharmacopoeias, are not reproducing the in vivo situation. This holds true for the hydrodynamics in the disintegration tester that generates Reynolds numbers dissimilar to the reported in vivo situation. Also, when using homogenized US FDA meal, representing the fed state, too high viscosities and relative pressures are generated. The forces acting on the dosage form are too small for all fluids compared to the in vivo situation. The lack of peristaltic contractions, which generate hydrodynamics and shear stress in vivo, might be the major drawback of the compendial device resulting in the observed differences between predicted and in vivo measured hydrodynamics. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.
Portable tester for determining gas content within a core sample
Garcia, Jr., Fred; Schatzel, Steven J.
1998-01-01
A portable tester is provided for reading and displaying the pressure of a gas released from a rock core sample stored within a sealed container and for taking a sample of the released pressurized gas for chemical analysis thereof for subsequent use in a modified direct method test which determines the volume of gas and specific type of gas contained within the core sample. The portable tester includes a pair of low and high range electrical pressure transducers for detecting a gas pressure; a pair of low and high range display units for displaying the pressure of the detected gas- a selector valve connected to the low and high range pressure transducers, a selector knob for selecting gas flow to one of the flow paths; control valve having an inlet connection to the sealed container, and outlets connected to: a sample gas canister, a second outlet port connected to the selector valve means for reading the pressure of the gas from the sealed container to either the low range or high range pressure transducers, and a connection for venting gas contained within the sealed container to the atmosphere. A battery is electrically connected to and supplies the power for operating the unit. The pressure transducers, display units, selector and control valve means and the battery is mounted to and housed within a protective casing for portable transport and use.
Portable tester for determining gas content within a core sample
Garcia, F. Jr.; Schatzel, S.J.
1998-04-21
A portable tester is provided for reading and displaying the pressure of a gas released from a rock core sample stored within a sealed container and for taking a sample of the released pressurized gas for chemical analysis thereof for subsequent use in a modified direct method test which determines the volume of gas and specific type of gas contained within the core sample. The portable tester includes a pair of low and high range electrical pressure transducers for detecting a gas pressure; a pair of low and high range display units for displaying the pressure of the detected gas; a selector valve connected to the low and high range pressure transducers and a selector knob for selecting gas flow to one of the flow paths; control valve having an inlet connection to the sealed container; and outlets connected to: a sample gas canister, a second outlet port connected to the selector valve means for reading the pressure of the gas from the sealed container to either the low range or high range pressure transducers, and a connection for venting gas contained within the sealed container to the atmosphere. A battery is electrically connected to and supplies the power for operating the unit. The pressure transducers, display units, selector and control valve means and the battery is mounted to and housed within a protective casing for portable transport and use. 5 figs.
Integrated approach for automatic target recognition using a network of collaborative sensors.
Mahalanobis, Abhijit; Van Nevel, Alan
2006-10-01
We introduce what is believed to be a novel concept by which several sensors with automatic target recognition (ATR) capability collaborate to recognize objects. Such an approach would be suitable for netted systems in which the sensors and platforms can coordinate to optimize end-to-end performance. We use correlation filtering techniques to facilitate the development of the concept, although other ATR algorithms may be easily substituted. Essentially, a self-configuring geometry of netted platforms is proposed that positions the sensors optimally with respect to each other, and takes into account the interactions among the sensor, the recognition algorithms, and the classes of the objects to be recognized. We show how such a paradigm optimizes overall performance, and illustrate the collaborative ATR scheme for recognizing targets in synthetic aperture radar imagery by using viewing position as a sensor parameter.
A model-driven approach to information security compliance
NASA Astrophysics Data System (ADS)
Correia, Anacleto; Gonçalves, António; Teodoro, M. Filomena
2017-06-01
The availability, integrity and confidentiality of information are fundamental to the long-term survival of any organization. Information security is a complex issue that must be holistically approached, combining assets that support corporate systems, in an extended network of business partners, vendors, customers and other stakeholders. This paper addresses the conception and implementation of information security systems, conform the ISO/IEC 27000 set of standards, using the model-driven approach. The process begins with the conception of a domain level model (computation independent model) based on information security vocabulary present in the ISO/IEC 27001 standard. Based on this model, after embedding in the model mandatory rules for attaining ISO/IEC 27001 conformance, a platform independent model is derived. Finally, a platform specific model serves the base for testing the compliance of information security systems with the ISO/IEC 27000 set of standards.
Gamification and service marketing.
Conaway, Roger; Garay, Mario Cortés
2014-01-01
Our paper addresses the development of the gamification concept with business applications. We report on our survey of customers and managers seeking to participate in gamification on their websites. We examined both customer and manager perspectives and compare survey results in terms of service marketing and characteristics of consumers who engage with gamification platforms. Our data supported a design theory delineating four key characteristics in gamification platforms that attract consumers toward an enterprise's website. Those features attract individuals through (1) Progress Paths, (2) Feedback and Reward, (3) Social Connection, and (4) Attractiveness of the site. Results from the managers' survey reflected key characteristics that must exist for implementation of a gamification platform. The data revealed a particular demographic profile of a gamification individual drawn to a website. These findings may help company managers who wish to adopt a gamification platform in the future.
A polyamidoamine dendrimer-streptavidin supramolecular architecture for biosensor development.
Soda, N; Arotiba, O A
2017-12-01
A novel polyamidoamine dendrimer-streptavidin supramolecular architecture suitable as a versatile platform for biosensor development is reported. The dendrimer was electrodeposited on a glassy carbon electrode via cyclic voltammetry. The dendrimer electrode was further modified with streptavidin by electrostatic attraction upon drop coating. The platform i.e. the dendrimer-streptavidin modified electrode was electrochemically interrogated in phosphate buffer, ferrocyanide and H 2 O 2 . The dendrimer-streptavidin platform was used in the preparation of a simple DNA biosensor as a proof of concept. The supramolecular architecture of dendrimer-streptavidin was stable, electroactive and thus lends itself as a versatile immobilisation layer for any biotinylated bioreceptors in biosensor development. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Rieker, Lorra L.; Haraburda, Francis M.
1989-01-01
The National Aeronautics and Space Administration has adopted the policy to achieve the maximum practical level of commonality for the Space Station Freedom program in order to significantly reduce life cycle costs. Commonality means using identical or similar hardware/software for meeting common sets of functionally similar requirements. Information on how the concept of commonality is being implemented with respect to electric power system hardware for the Space Station Freedom and the U.S. Polar Platform is presented. Included is a historical account of the candidate common items which have the potential to serve the same power system functions on both Freedom and the Polar Platform.
Paris, Juan L; de la Torre, Paz; Victoria Cabañas, M; Manzano, Miguel; Grau, Montserrat; Flores, Ana I; Vallet-Regí, María
2017-05-04
A new platform constituted by engineered responsive nanoparticles transported by human mesenchymal stem cells is here presented as a proof of concept. Ultrasound-responsive mesoporous silica nanoparticles are coated with polyethylenimine to favor their effective uptake by decidua-derived mesenchymal stem cells. The responsive-release ability of the designed nanoparticles is confirmed, both in vial and in vivo. In addition, this capability is maintained inside the cells used as carriers. The migration capacity of the nanoparticle-cell platform towards mammary tumors is assessed in vitro. The efficacy of this platform for anticancer therapy is shown against mammary tumor cells by inducing the release of doxorubicin only when the cell vehicles are exposed to ultrasound.
Force level EW in the Australian Defence Force
NASA Astrophysics Data System (ADS)
Finn, Anthony; Chalmers, Greg; Pincombe, Adrian
2001-08-01
The Australian Defence Force is a small force, dependent upon a few high value assets that act as force multipliers. Consequently, it cannot afford to sustain high attrition. The current Concept of Operations for these platforms is to operate them outside the threat envelope. Organic sensors and data links are used to maintain Situational Awareness, Combat Air Patrol is used to intercept hostile missile launch platforms, and Electronic Warfare self-protection is used as a last resort. Unfortunately, it is common for such high value assets to be slowly, non-stealthy, low agility, physically large platforms that follow predictable trajectories. Consequently, they are easy to target and track from a long range and have a high `sitting duck' factor.
Gas diffusion as a new fluidic unit operation for centrifugal microfluidic platforms.
Ymbern, Oriol; Sández, Natàlia; Calvo-López, Antonio; Puyol, Mar; Alonso-Chamarro, Julian
2014-03-07
A centrifugal microfluidic platform prototype with an integrated membrane for gas diffusion is presented for the first time. The centrifugal platform allows multiple and parallel analysis on a single disk and integrates at least ten independent microfluidic subunits, which allow both calibration and sample determination. It is constructed with a polymeric substrate material and it is designed to perform colorimetric determinations by the use of a simple miniaturized optical detection system. The determination of three different analytes, sulfur dioxide, nitrite and carbon dioxide, is carried out as a proof of concept of a versatile microfluidic system for the determination of analytes which involve a gas diffusion separation step during the analytical procedure.
Developing a Framework for Control of Agile Aircraft Platforms in Autonomous Hover
2009-03-01
profiles. Two dynamical systems are considered, a scale YAK -54 aerobatic remote control aircraft and the Flexrotor concept developed by Aerovel. Both models...System [28]. . . . . . . 2 1.2 A YAK -54 in hover in the Real Flight RC Simulator [24]. . . . . . . . 3 1.3 The Aerovel Flexrotor concept...17 3.1 A three-view of the YAK -54 showing all geometry and dimensions (in mm) [15
Intelligent interface design and evaluation
NASA Technical Reports Server (NTRS)
Greitzer, Frank L.
1988-01-01
Intelligent interface concepts and systematic approaches to assessing their functionality are discussed. Four general features of intelligent interfaces are described: interaction efficiency, subtask automation, context sensitivity, and use of an appropriate design metaphor. Three evaluation methods are discussed: Functional Analysis, Part-Task Evaluation, and Operational Testing. Design and evaluation concepts are illustrated with examples from a prototype expert system interface for environmental control and life support systems for manned space platforms.
An Open Service Provider Concept for Enterprise Complex Automation
NASA Astrophysics Data System (ADS)
Ivaschenko, A. V.; Sitnikov, P. V.; Tanonykhina, M. O.
2017-01-01
The paper introduces a solution for IT services representation and management in the integrated information space of distributed enterprises. It is proposed to develop an Open Service Provider as a software platform for interaction between IT services providers and their users. Implementation of the proposed concept and approach is illustrated by an after-sales customer support system for a large manufacturing corporation delivered by SEC “Open Code”.
Space Assembly, Maintenance and Servicing Study. Volume 4: Concept Development Plan.
1986-01-01
development of the concept development program (COP) plan: 1) Develop the CDP candidate work sheets 2) Categorize by application 3) Prioritize by... categorized under the ORU change-out section of this report, the large system assembly area will attempt to cover the EVA aspects of SAMS not discussed...space assemblies involve the evolvement of technologies related to multilevel orbital operating platforms on which both individual and cooperative
Lim, H P; Fong, Y K
2005-01-01
Basidiospores were isolated from the fruiting bodies of Ganoderma infecting oil palms from an estate in Johor and from ornamental palms (including oil palms) from Singapore. The spores were then germinated to obtain homokaryotic mycelia. Based on clamp connection formation in paired hyphal fusions, tester strains were identified from the homokaryons isolated. Compatibility tests were then carried out using these testers to determine the relatedness of the homokaryotic Ganoderma isolates, both from Johor and from Singapore. Results from the compatibility tests showed that Ganoderma from both locations belong to the same species, while the Ganoderma isolates from Singapore share some common alleles. The pathogenicity tests carried out on Chrysalidocarpus lutescens seedlings using inoculum growing on rubber wood blocks showed that dikaryotic mycelia can cause basal stem rot infection.
NASA Astrophysics Data System (ADS)
Rau, T. H.
1982-07-01
Measured and extrapolated data define the bioacoustic environments produced by a gasoline engine driven cabin leakage tester operating outdoors on a concrete apron at normal rated conditions. Near field data are presented for 37 locations at a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise level, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors. Far-field data measured at 36 locations are normalized to standard meteorological conditions and extrapolated from 10 - 1600 meters to derive sets of equal-value contours for these same seven acoustic measures as functions of angle and distance from the source.
NASA Astrophysics Data System (ADS)
El-Tarfawy, S. Y.
2017-10-01
There are various methods to evaluate knitted fabric’s properties; the yarn pulling force is a suitable experimental method to investigate the properties of single jersey knitted fabric.In this study, a frame is attached to the electronic tensile strength tester to fix different single jersey knitted fabrics with different dimensional properties. A hook is connected to the upper load cell in the tensile tester to ravel the first upper course then records the values of the yarn pulling force. In addition to that, the effect of the loop length, yarn count, and raw material on yarn pulling force and specific fabric bursting strength are studied. It is concluded that yarn pulling force has a significant relation with specific fabric bursting strength.
Implementation Considerations for Multisite Clinical Trials with Cognitive Neuroscience Tasks
Keefe, Richard S. E.; Harvey, Philip D.
2008-01-01
Multisite clinical trials aimed at cognitive enhancement across various neuropsychiatric conditions have employed standard neuropsychological tests as outcome measures. While these tests have enjoyed wide clinical use and have proven reliable and predictive of functional disability, a number of implementation challenges have arisen when these tests are used in clinical trials. These issues are likely to be magnified in future studies when cognitive neuroscience (CN) procedures are explored in these trials, because in their current forms CN procedures are less standardized and more difficult to teach and monitor. For multisite trials, we anticipate that the most challenging issues will include assuring tester competence, monitoring tester performance, specific challenges with complex assessment methods, and having resources available for adequate monitoring of data quality. Suggestions for overcoming these implementation challenges are offered. PMID:18495645
Microprocessor tester for the treat upgrade reactor trip system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lenkszus, F.R.; Bucher, R.G.
1984-01-01
The upgrading of the Transient Reactor Test (TREAT) Facility at ANL-Idaho has been designed to provide additional experimental capabilities for the study of core disruptive accident (CDA) phenomena. In addition, a programmable Automated Reactor Control System (ARCS) will permit high-power transients up to 11,000 MW having a controlled reactor period of from 15 to 0.1 sec. These modifications to the core neutronics will improve simulation of LMFBR accident conditions. Finally, a sophisticated, multiply-redundant safety system, the Reactor Trip System (RTS), will provide safe operation for both steady state and transient production operating modes. To insure that this complex safety systemmore » is functioning properly, a Dedicated Microprocessor Tester (DMT) has been implemented to perform a thorough checkout of the RTS prior to all TREAT operations.« less
Unique Offerings of the ISS as an Earth Observing Platform
NASA Technical Reports Server (NTRS)
Cooley, Victor M.
2013-01-01
The International Space Station offers unique capabilities for earth remote sensing. An established Earth orbiting platform with abundant power, data and commanding infrastructure, the ISS has been in operation for twelve years as a crew occupied science laboratory and offers low cost and expedited concept-to-operation paths for new sensing technologies. Plug in modularity on external platforms equipped with structural, power and data interfaces standardizes and streamlines integration and minimizes risk and start up difficulties. Data dissemination is also standardized. Emerging sensor technologies and instruments tailored for sensing of regional dynamics may not be worthy of dedicated platforms and launch vehicles, but may well be worthy of ISS deployment, hitching a ride on one of a variety of government or commercial visiting vehicles. As global acceptance of the urgent need for understanding Climate Change continues to grow, the value of ISS, orbiting in Low Earth Orbit, in complementing airborne, sun synchronous polar, geosynchronous and other platform remote sensing will also grow.
Space platform expendables resupply concept definition study. Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
1984-01-01
NASA has recognized that the capability for remote resupply of space platform expendable fluids will help transition space utilization into a new era of operational efficiency and cost/effectiveness. The emerging Orbital Maneuvering System (OMV) in conjunction with an expendables resupply module will introduce the capability for fluid resupply enabling satellite lifetime extension at locations beyond the range of the Orbiter. This report summarizes a Phase A study of a remote resupply module for the OMV. Volume 1 is the executive summary.
Architectural design and support for knowledge sharing across heterogeneous MAST systems
NASA Astrophysics Data System (ADS)
Arkin, Ronald C.; Garcia-Vergara, Sergio; Lee, Sung G.
2012-06-01
A novel approach for the sharing of knowledge between widely heterogeneous robotic agents is presented, drawing upon Gardenfors Conceptual Spaces approach [4]. The target microrobotic platforms considered are computationally, power, sensor, and communications impoverished compared to more traditional robotics platforms due to their small size. This produces novel challenges for the system to converge on an interpretation of events within the world, in this case specifically focusing on the task of recognizing the concept of a biohazard in an indoor setting.
Space platform expendables resupply concept definition study
NASA Technical Reports Server (NTRS)
1985-01-01
NASA has recognized that the capability for remote resupply of space platform expendable fluids will help transition space utilization into a new era of operational efficiency and cost/effectiveness. The emerging Orbital Maneuvering System (OMV) in conjunction with an expendables resupply module will introduce the capability for fluid resupply enabling satellite lifetime extension at locations beyond the range of the Orbiter. This report summarizes a supplemental study to the original Phase A study and is presented as addenda to that study.
Space platform expendables resupply concept definition study, volume 2
NASA Technical Reports Server (NTRS)
1984-01-01
NASA has recognized that the capability for remote resupply of space platform expendable fluids will help transition space utilization into a new era of operational efficiency and cost/effectiveness. The emerging Orbital Maneuvering System (OMV) in conjunction with an expendables resupply module will introduce the capability for fluid resupply enabling satellite lifetime extension at locations beyond the range of the Orbiter. This report summarizes a Phase A study of a remote resupply module for the OMV. Volume 2 represents study results.
NASA Technical Reports Server (NTRS)
Naftel, Chris
2014-01-01
The NASA Global Hawk Project is supporting Earth Science research customers. These customers include: US Government agencies, civilian organizations, and universities. The combination of the Global Hawks range, endurance, altitude, payload power, payload volume and payload weight capabilities separates the Global Hawk platform from all other platforms available to the science community. This presentation includes an overview of the concept of operations and an overview of the completed science campaigns. In addition, the future science plans, using the NASA Global Hawk System, will be presented.
Study of thermal management for space platform applications
NASA Technical Reports Server (NTRS)
Oren, J. A.
1980-01-01
Techniques for the management of the thermal energy of large space platforms using many hundreds of kilowatts over a 10 year life span were evaluated. Concepts for heat rejection, heat transport within the vehicle, and interfacing were analyzed and compared. The heat rejection systems were parametrically weight optimized over conditions for heat pipe and pumped fluid approaches. Two approaches to achieve reliability were compared for: performance, weight, volume, projected area, reliability, cost, and operational characteristics. Technology needs are assessed and technology advancement recommendations are made.
Ixion: A Wet-Lab Habitat Platform for Leo and the Deep Space Gateway
NASA Astrophysics Data System (ADS)
Wald, S. I.; Cummins, C. K.; Manber, J.
2018-02-01
Cislunar and LEO habitats derived from launch vehicle upper stages are technically feasible and continues development toward flight. Present station specifications, configurations, and concepts for scientific, exploration, and commercial utilization.
Code of Federal Regulations, 2010 CFR
2010-04-01
... training or be experienced in testing procedures and techniques. (d) Testers and the organizations... competitor of the person or organization to be tested in the listing, rental, sale, or financing of real...
NASA Astrophysics Data System (ADS)
Demir, I.
2015-12-01
Recent developments in internet technologies make it possible to manage and visualize large data on the web. Novel visualization techniques and interactive user interfaces allow users to create realistic environments, and interact with data to gain insight from simulations and environmental observations. This presentation showcase information communication interfaces, games, and virtual and immersive reality applications for supporting teaching and learning of concepts in atmospheric and hydrological sciences. The information communication platforms utilizes latest web technologies and allow accessing and visualizing large scale data on the web. The simulation system is a web-based 3D interactive learning environment for teaching hydrological and atmospheric processes and concepts. The simulation systems provides a visually striking platform with realistic terrain and weather information, and water simulation. The web-based simulation system provides an environment for students to learn about the earth science processes, and effects of development and human activity on the terrain. Users can access the system in three visualization modes including virtual reality, augmented reality, and immersive reality using heads-up display. The system provides various scenarios customized to fit the age and education level of various users.
Experiments to evolve toward a tangible user interface for computer-aided design parts assembly
NASA Astrophysics Data System (ADS)
Legardeur, Jeremy; Garreau, Ludovic; Couture, Nadine
2004-05-01
In this paper, we present the concepts of the ESKUA (Experimentation of a Kinesics System Usable for Assembly) platform that allows designers to carry out the assembly of mechanical CAD (Computer Aided Design) parts. This platform, based on tangible user interface lead taking into account assembly constraints from the beginning of the design phase and especially during the phase of CAD models manipulation. Our goal is to propose a working environment where the designer is confronted with real assembly constraints which are currently masked by existing CAD software functionalities. Thus, the platform is based on the handling of physical objects, called tangible interactors, which enable having a physical perception of the assembly constraints. In this goal, we have defined a typology of interactors based on concepts proposed in Design For Assembly methods. We present here the results of studies that led to the evolution of this first interactors set. One is concerning an experiment to evaluate the cognitive aspects of the use of interactors. The other is about an analysis of existing mechanical product and fasteners. We will show how these studies lead to the evolution of the interactors based on the functional surfaces use.
PRELIMINARY STUDY OF THE PRESSURE TRANSDUCER PROJECT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eldridge, A.J.
1956-08-01
A feasibility study is presented of the application of several commercially available pressure transducers for incorporation in a dynamic baro- switch tester or for use in a baro-switch application. (auth)
Pedowitz, Robert A; Nicandri, Gregg T; Angelo, Richard L; Ryu, Richard K N; Gallagher, Anthony G
2015-10-01
To assess a new method for biomechanical assessment of arthroscopic knots and to establish proficiency benchmarks using the Fundamentals of Arthroscopic Surgery Training (FAST) Program workstation and knot tester. The first study group included 20 faculty at an Arthroscopy Association of North America resident arthroscopy course (19.9 ± 8.25 years in practice). The second group comprised 30 experienced surgeons attending an Arthroscopy Association of North America fall course (17.1 ± 19.3 years in practice). The training group included 44 postgraduate year 4 or 5 orthopaedic residents in a randomized, prospective study of proficiency-based training, with 3 subgroups: group A, standard training (n = 14); group B, workstation practice (n = 14); and group C, proficiency-based progression using the knot tester (n = 16). Each subject tied 5 arthroscopic knots backed up by 3 reversed hitches on alternating posts. Knots were tied under video control around a metal mandrel through a cannula within an opaque dome (FAST workstation). Each suture loop was stressed statically at 15 lb for 15 seconds. A calibrated sizer measured loop expansion. Knot failure was defined as 3 mm of loop expansion or greater. In the faculty group, 24% of knots "failed" under load. Performance was inconsistent: 12 faculty had all knots pass, whereas 2 had all knots fail. In the second group of practicing surgeons, 21% of the knots failed under load. Overall, 56 of 250 knots (22%) tied by experienced surgeons failed. For the postgraduate year 4 or 5 residents, the aggregate knot failure rate was 26% for the 220 knots tied. Group C residents had an 11% knot failure rate (half the overall faculty rate, P = .013). The FAST workstation and knot tester offer a simple and reproducible educational approach for enhancement of arthroscopic knot-tying skills. Our data suggest that there is significant room for improvement in the quality and consistency of these important arthroscopic skills, even for experienced arthroscopic surgeons. Level II, prospective comparative study. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Hoenigl, Martin; Anderson, Christy M; Green, Nella; Mehta, Sanjay R; Smith, Davey M; Little, Susan J
2015-09-11
The Center for Disease Control and Prevention recommends that high-risk groups, like sexually active men who have sex with men (MSM), receive HIV testing and counseling at least annually. The objective of this study was to investigate the relationship between voluntary repeat HIV testing and sexual risk behavior in MSM receiving rapid serologic and nucleic acid amplification testing. We performed a cohort study to analyze reported risk behavior among MSM receiving the "Early Test", a community-based, confidential acute and early HIV infection screening program in San Diego, California, between April 2008 and July 2014. The study included 8,935 MSM receiving 17,333 "Early Tests". A previously published risk behavior score for HIV acquisition in MSM (i.e. Menza score) was chosen as an outcome to assess associations between risk behaviors and number of repeated tests. At baseline, repeat-testers (n = 3,202) reported more male partners and more condomless receptive anal intercourse (CRAI) when compared to single-testers (n = 5,405, all P <0.001). In 2,457 repeat testers there was a strong association observed between repeated HIV tests obtained and increased risk behavior, with number of male partners, CRAI with high risk persons, non-injection stimulant drug use, and sexually transmitted infections all increasing between the first and last test. There was also a linear increase of risk (i.e. high Menza scores) with number of tests up to the 17th test. In the multivariable mixed effects model, more HIV tests (OR = 1.18 for each doubling of the number of tests, P <0.001) and younger age (OR = 0.95 per 5-year increase, P = 0.006) had significant associations with high Menza scores. This study found that the highest risk individuals for acquiring HIV (e.g. candidates for antiretroviral pre-exposure prophylaxis) can be identified by their testing patterns. Future studies should delineate causation versus association to improve prevention messages delivered to repeat testers during HIV testing and counseling sessions.
Workplace field testing of the pressure drop of particulate respirators using welding fumes.
Cho, Hyun-Woo; Yoon, Chung-Sik
2012-10-01
In a previous study, we concluded that respirator testing with a sodium chloride aerosol gave a conservative estimate of filter penetration for welding fume aerosols. A rapid increase in the pressure drop (PD) of some respirators was observed as fumes accumulated on the filters. The present study evaluated particulate respirator PD based on workplace field tests. A field PD tester was designed and validated using the TSI 8130 Automatic Filter Tester, designed in compliance with National Institute for Occupational and Safety and Health regulation 42 CFR part 84. Three models (two replaceable dual-type filters and one replaceable single-type filter) were evaluated against CO(2) gas arc welding on mild steel in confined booths in the workplace. Field tests were performed under four airborne concentrations (27.5, 15.4, 7.9, and 2.1 mg m(-3)). The mass concentration was measured by the gravimetric method, and number concentration was monitored using P-Trak (Model 8525, TSI, USA). Additionally, photos and scanning electron microscopy-energy dispersive X-ray spectroscopy were used to visualize and analyze the composition of welding fumes trapped in the filters. The field PD tester showed no significant difference compared with the TSI tester. There was no significant difference in the initial PD between laboratory and field results. The PD increased as a function of fume load on the respirator filters for all tested models. The increasing PD trend differed by models, and PD increased rapidly at high concentrations because greater amount of fumes accumulated on the filters in a given time. The increase in PD as a function of fume load on the filters showed a similar pattern as fume load varied for a particular model, but different patterns were observed for different models. Images and elemental analyses of fumes trapped on the respirator filters showed that most welding fumes were trapped within the first layer, outer web cover, and second layer, in order, while no fumes were observed beneath the fourth layer of the tested respirators. The current findings contribute substantially to our understanding of respirator PD in the presence of welding fumes.
Dollman, James
2005-01-01
The 'Learning Trail' is an innovative application of peer-mediated instruction designed to enhance student learning in large practical classes. The strategy specifically seeks to improve participants' attention to details of protocol that are often difficult to observe during teacher-centered demonstrations to large groups. Students (n=68) at the University of South Australia trialed this strategy, in which instruction in anthropometric techniques is initiated by an instructor to a group of 3-4 students and then sent in 'waves' from one student group to the next. The final group in the sequence demonstrates the techniques to the instructor, who notes any departures from technical accuracy. As each technical module is flowing from group to group, the instructor initiates the next 'wave' with the first group, and the process is repeated until all of the relevant skills are processed. The final stage is a full class discussion during which sources of technical error are identified and resolved. In this trial, students taught skinfold measurement by the peer instructed method (PI; n=33) were compared with a traditionally instructed group (TI; n=35), in which the instructor was responsible for all information transfer. For each participant, technical errors of measurement (TEM) were calculated; the intra-tester TEM as a measure of reliability, and the inter-tester TEM, in which the student's measures are compared with those of a criterion anthropometrist to give an indication of validity. There were no differences between TI and PI groups on intra-tester TEM (p=0.24), but the PI group had a lower inter-tester TEM for pooled skinfold sites (p=0.006) and for one individual site (triceps; p=0.007), but not the other three sites. The time taken to complete the whole set of instructions did not differ between delivery modes. The results of this trial suggest that the peer-mediated strategy may be more effective than teacher-centered instruction in terms of technical accuracy in anthropometry.
Visser, Maartje; Heijne, Janneke C M; Hogewoning, Arjan A; van Aar, Fleur
2017-09-01
Men who have sex with men (MSM) are at highest risk for STIs and HIV infections in the Netherlands. However, official guidelines on STI testing among MSM are lacking. They are advised to test for STIs at least every six months, but their testing behaviour is not well known. This study aimed to get insight into the proportion and determinants of consistent 6-monthly STI testing among MSM testing at STI outpatient clinics in the Netherlands. This study included longitudinal surveillance data of STI consultations among MSM from all 26 STI outpatient clinics in the Netherlands between 1 June 2014 and 31 December 2015. Multinomial logistic regression analysis was used to identify determinants of consistent 6-monthly testing compared with single testing and inconsistent testing. Determinants of time between consultations among men with multiple consultations were analysed using a Cox Prentice-Williams-Peterson gap-time model. A total of 34 605 STI consultations of 18 634 MSM were included. 8966 (48.1%) men had more than one consultation, and 3516 (18.9%) men tested consistently 6-monthly. Indicators of high sexual risk behaviour, including having a history of STI, being HIV positive and having more than 10 sex partners, were positively associated with both being a consistent tester and returning to the STI clinic sooner. Men who were notified by a partner or who reported STI symptoms were also more likely to return to the STI clinic sooner, but were less likely to be consistent testers, identifying a group of event-driven testers. The proportion of consistent 6-monthly testers among MSM visiting Dutch STI outpatient clinics was low. Testing behaviour was associated with sexual risk behaviour, but exact motives to test consistently remain unclear. Evidence-based testing guidelines are needed to achieve optimal reductions in STI transmission in the future. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
BrainFrame: a node-level heterogeneous accelerator platform for neuron simulations
NASA Astrophysics Data System (ADS)
Smaragdos, Georgios; Chatzikonstantis, Georgios; Kukreja, Rahul; Sidiropoulos, Harry; Rodopoulos, Dimitrios; Sourdis, Ioannis; Al-Ars, Zaid; Kachris, Christoforos; Soudris, Dimitrios; De Zeeuw, Chris I.; Strydis, Christos
2017-12-01
Objective. The advent of high-performance computing (HPC) in recent years has led to its increasing use in brain studies through computational models. The scale and complexity of such models are constantly increasing, leading to challenging computational requirements. Even though modern HPC platforms can often deal with such challenges, the vast diversity of the modeling field does not permit for a homogeneous acceleration platform to effectively address the complete array of modeling requirements. Approach. In this paper we propose and build BrainFrame, a heterogeneous acceleration platform that incorporates three distinct acceleration technologies, an Intel Xeon-Phi CPU, a NVidia GP-GPU and a Maxeler Dataflow Engine. The PyNN software framework is also integrated into the platform. As a challenging proof of concept, we analyze the performance of BrainFrame on different experiment instances of a state-of-the-art neuron model, representing the inferior-olivary nucleus using a biophysically-meaningful, extended Hodgkin-Huxley representation. The model instances take into account not only the neuronal-network dimensions but also different network-connectivity densities, which can drastically affect the workload’s performance characteristics. Main results. The combined use of different HPC technologies demonstrates that BrainFrame is better able to cope with the modeling diversity encountered in realistic experiments while at the same time running on significantly lower energy budgets. Our performance analysis clearly shows that the model directly affects performance and all three technologies are required to cope with all the model use cases. Significance. The BrainFrame framework is designed to transparently configure and select the appropriate back-end accelerator technology for use per simulation run. The PyNN integration provides a familiar bridge to the vast number of models already available. Additionally, it gives a clear roadmap for extending the platform support beyond the proof of concept, with improved usability and directly useful features to the computational-neuroscience community, paving the way for wider adoption.
BrainFrame: a node-level heterogeneous accelerator platform for neuron simulations.
Smaragdos, Georgios; Chatzikonstantis, Georgios; Kukreja, Rahul; Sidiropoulos, Harry; Rodopoulos, Dimitrios; Sourdis, Ioannis; Al-Ars, Zaid; Kachris, Christoforos; Soudris, Dimitrios; De Zeeuw, Chris I; Strydis, Christos
2017-12-01
The advent of high-performance computing (HPC) in recent years has led to its increasing use in brain studies through computational models. The scale and complexity of such models are constantly increasing, leading to challenging computational requirements. Even though modern HPC platforms can often deal with such challenges, the vast diversity of the modeling field does not permit for a homogeneous acceleration platform to effectively address the complete array of modeling requirements. In this paper we propose and build BrainFrame, a heterogeneous acceleration platform that incorporates three distinct acceleration technologies, an Intel Xeon-Phi CPU, a NVidia GP-GPU and a Maxeler Dataflow Engine. The PyNN software framework is also integrated into the platform. As a challenging proof of concept, we analyze the performance of BrainFrame on different experiment instances of a state-of-the-art neuron model, representing the inferior-olivary nucleus using a biophysically-meaningful, extended Hodgkin-Huxley representation. The model instances take into account not only the neuronal-network dimensions but also different network-connectivity densities, which can drastically affect the workload's performance characteristics. The combined use of different HPC technologies demonstrates that BrainFrame is better able to cope with the modeling diversity encountered in realistic experiments while at the same time running on significantly lower energy budgets. Our performance analysis clearly shows that the model directly affects performance and all three technologies are required to cope with all the model use cases. The BrainFrame framework is designed to transparently configure and select the appropriate back-end accelerator technology for use per simulation run. The PyNN integration provides a familiar bridge to the vast number of models already available. Additionally, it gives a clear roadmap for extending the platform support beyond the proof of concept, with improved usability and directly useful features to the computational-neuroscience community, paving the way for wider adoption.
Development of Mobile Electronic Health Records Application in a Secondary General Hospital in Korea
Park, Min Ah; Hong, Eunseok; Kim, Sunhyu; Ahn, Ryeok; Hong, Jungseok; Song, Seungyeol; Kim, Tak; Kim, Jeongkeun; Yeo, Seongwoon
2013-01-01
Objectives The recent evolution of mobile devices has opened new possibilities of providing strongly integrated mobile services in healthcare. The objective of this paper is to describe the decision driver, development, and implementation of an integrated mobile Electronic Health Record (EHR) application at Ulsan University Hospital. This application helps healthcare providers view patients' medical records and information without a stationary computer workstation. Methods We developed an integrated mobile application prototype that aimed to improve the mobility and usability of healthcare providers during their daily medical activities. The Android and iOS platform was used to create the mobile EHR application. The first working version was completed in 5 months and required 1,080 development hours. Results The mobile EHR application provides patient vital signs, patient data, text communication, and integrated EHR. The application allows our healthcare providers to know the status of patients within and outside the hospital environment. The application provides a consistent user environment on several compatible Android and iOS devices. A group of 10 beta testers has consistently used and maintained our copy of the application, suggesting user acceptance. Conclusions We are developing the integrated mobile EHR application with the goals of implementing an environment that is user-friendly, implementing a patient-centered system, and increasing the hospital's competitiveness. PMID:24523996
Impact attenuation properties of jazz shoes alter lower limb joint stiffness during jump landings.
Fong Yan, Alycia; Smith, Richard M; Hiller, Claire E; Sinclair, Peter J
2017-05-01
To quantify the impact attenuation properties of the jazz shoes, and to investigate the in-vivo effect of four jazz shoe designs on lower limb joint stiffness during a dance-specific jump. Repeated measures. A custom-built mechanical shoe tester similar to that used by athletic shoe companies was used to vertically impact the forefoot and heel region of four different jazz shoe designs. Additionally, dancers performed eight sautés in second position in bare feet and the shoe conditions. Force platforms and 3D-motion capture were used to analyse the joint stiffness of the midfoot, ankle, knee and hip during the jump landings. Mechanical testing of the jazz shoes revealed significant differences in impact attenuation characteristics among each of the jazz shoe designs. Gross knee and midfoot joint stiffness were significantly affected by the jazz shoe designs in the dancers' jump landings. The tested jazz shoe designs altered the impact attenuating capacity of jump landing technique in dancers. The cushioned jazz shoes are recommended particularly for injured dancers to reduce impact on the lower limb. Jazz shoe design should consider the impact attenuation properties of the forefoot region, due to the toe-strike landing technique in dance movement. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.