Sample records for testing demonstrated significant

  1. Final Environmental Assessment for Conventional Strike Missile Demonstration

    DTIC Science & Technology

    2010-08-11

    impacts of conducting a single demonstration flight test of the Conventional Strike Missile (CSM). The CSM Demonstration flight test vehicle would...Vehicle would glide at hypersonic velocities in the upper atmosphere, prior to a land or ocean impact at the US Army Kwajalein Atoll/Reagan Test Site...SIGNIFICANT IMPACT ENVIRONMENTAL ASSESSMENT FOR CONVENTIONAL STRIKE MISSILE DEMONSTRATION AGENCY: United States Air Force (USAF) BACKGROUND

  2. Antimicrobial effects of a new therapeutic liquid dentifrice formulation on oral bacteria including odorigenic species.

    PubMed

    Sreenivasan, P K; Furgang, D; Zhang, Y; DeVizio, W; Fine, D H

    2005-03-01

    The control of oral malodor is well-recognized in efforts to improve oral health. Antimicrobial formulations can mitigate oral malodor, however, procedures to assess effects on oral bacteria including those implicated in halitosis are unavailable. This investigation examined the antimicrobial effects of a new liquid triclosan/copolymer dentifrice (test) formulation that demonstrated significant inhibition of oral malodor in previous organoleptic clinical studies. Procedures compared antimicrobial effects of the test and control formulations on a range of oral micro-organisms including members implicated in halitosis, substantive antimicrobial effects of formulations with hydroxyapatite as a surrogate for human teeth and ex vivo effects on oral bacteria from human volunteers. With Actinomyces viscosus, as a model system, the test formulation demonstrated a dose-dependent effect. At these concentrations the test formulation provided significant antimicrobial effects on 13 strains of oral bacteria including those implicated in bad breath at selected posttreatment time points. Treatment of hydroxyapatite by the test dentifrice resulted in a significant and substantive antimicrobial effect vs. controls. Oral bacteria from subjects treated ex vivo with the test dentifrice resulted in significant reductions in cultivable oral bacteria and odorigenic bacteria producing hydrogen sulfide. In summary, microbiological methods adapted to study odorigenic bacteria demonstrate the significant antimicrobial effects of the test (triclosan/copolymer) dentifrice with laboratory and clinical strains of oral bacteria implicated in bad breath.

  3. A Comparison of Implosive Therapy and Systematic Desensitization in the Treatment of Test Anxiety

    ERIC Educational Resources Information Center

    Smith, Ronald E.; Nye, S. Lee

    1973-01-01

    Both Desensitization and implosive therapy resulted in significant decreases in scores on Sarason's Test Anxiety Scale. However, the desensitization group also demonstrated a significant reduction in state anxiety assessed during simulated testing sessions and a significant increase in grade point average, while the implosive therapy group showed…

  4. SSME Key Operations Demonstration

    NASA Technical Reports Server (NTRS)

    Anderson, Brian; Bradley, Michael; Ives, Janet

    1997-01-01

    A Space Shuttle Main Engine (SSME) test program was conducted between August 1995 and May 1996 using the Technology Test Bed (TTB) Engine. SSTO vehicle studies have indicated that increases in the propulsion system operating range can save significant weight and cost at the vehicle level. This test program demonstrated the ability of the SSME to accommodate a wide variation in safe operating ranges and therefore its applicability to the SSTO mission. A total of eight tests were completed with four at Marshall Space Flight Center's Advanced Engine Test Facility and four at the Stennis Space Center (SSC) A-2 attitude test stand. Key demonstration objectives were: 1) Mainstage operation at 5.4 to 6.9 mixture ratio; 2) Nominal engine start with significantly reduced engine inlet pressures of 50 psia LOX and 38 psia fuel; and 3) Low power level operation at 17%, 22%, 27%, 40%, 45%, and 50% of Rated Power Level. Use of the highly instrumented TTB engine for this test series has afforded the opportunity to study in great detail engine system operation not possible with a standard SSME and has significantly contributed to a greater understanding of the capabilities of the SSME and liquid rocket engines in general.

  5. Significant lexical relationships

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pedersen, T.; Kayaalp, M.; Bruce, R.

    Statistical NLP inevitably deals with a large number of rare events. As a consequence, NLP data often violates the assumptions implicit in traditional statistical procedures such as significance testing. We describe a significance test, an exact conditional test, that is appropriate for NLP data and can be performed using freely available software. We apply this test to the study of lexical relationships and demonstrate that the results obtained using this test are both theoretically more reliable and different from the results obtained using previously applied tests.

  6. Assessment of statistical significance and clinical relevance.

    PubMed

    Kieser, Meinhard; Friede, Tim; Gondan, Matthias

    2013-05-10

    In drug development, it is well accepted that a successful study will demonstrate not only a statistically significant result but also a clinically relevant effect size. Whereas standard hypothesis tests are used to demonstrate the former, it is less clear how the latter should be established. In the first part of this paper, we consider the responder analysis approach and study the performance of locally optimal rank tests when the outcome distribution is a mixture of responder and non-responder distributions. We find that these tests are quite sensitive to their planning assumptions and have therefore not really any advantage over standard tests such as the t-test and the Wilcoxon-Mann-Whitney test, which perform overall well and can be recommended for applications. In the second part, we present a new approach to the assessment of clinical relevance based on the so-called relative effect (or probabilistic index) and derive appropriate sample size formulae for the design of studies aiming at demonstrating both a statistically significant and clinically relevant effect. Referring to recent studies in multiple sclerosis, we discuss potential issues in the application of this approach. Copyright © 2012 John Wiley & Sons, Ltd.

  7. HEALTH SIGNIFICANCE OF PULMONARY FUNCTION TESTS

    EPA Science Inventory

    As the sensitivity and precision of functional tests improves, we become increasingly able to measure responses to pollutant exposures with little, if any, demonstrable health significance. Proper interpretation of such functional responses generally requires an ability to evalua...

  8. Nuclear anxiety: a test-construction study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Braunstein, A.L.

    1986-01-01

    The Nuclear Anxiety Scale was administered to 263 undergraduate and graduate studies (on eight occasions in December, 1985 and January, 1986). (1) The obtained alpha coefficient was .91. This was significant at the .01 level, and demonstrated that the scale was internally homogeneous and consistent. (2) Item discrimination indices (point biserial correlation coefficients) computered for the thirty (30) items yielded a range of .25 to .64. All coefficients were significant at the .01 level, and all 30 items were retained as demonstrating significant discriminability. (3) The correlation between two administrations of the scale (with a 48-hour interval) was .83. Thismore » was significant at the .01 level, and demonstrated test-retest reliability and stability over time. (4) The point-biserial correlation coefficient between scores on the Nuclear Anxiety Scale, and the students' self-report of nuclear anxiety as being either a high or low ranked stressor, was .59. This was significant at the .01 level, and demonstrated concurrent validity. (5) The correlation coefficient between scores on the Nuclear Anxiety Scale and the Spielberger State-Trait Anxiety Inventory, A-Trait, (1970), was .41. This was significant at the .01 level, and demonstrated convergent validity. (6) The correlation coefficient between positively stated and negatively stated items (with scoring reversed) was .76. This was significant at the .01 level, and demonstrated freedom from response set bias.« less

  9. Cycling induced by electrical stimulation improves motor recovery in postacute hemiparetic patients: a randomized controlled trial.

    PubMed

    Ambrosini, Emilia; Ferrante, Simona; Pedrocchi, Alessandra; Ferrigno, Giancarlo; Molteni, Franco

    2011-04-01

    This study assessed whether cycling induced by functional electrical stimulation (FES) was more effective than passive cycling with placebo stimulation in promoting motor recovery and walking ability in postacute hemiparetic patients. In a double-blind, randomized, controlled trial, 35 patients were included and randomized to receive FES-induced cycling training or placebo FES cycling. The 4-week treatment consisted of 20 sessions lasting 25 minutes each. Primary outcome measures included the leg subscale of the Motricity Index and gait speed during a 50-meter walking test. Secondary outcomes were the Trunk Control Test, the Upright Motor Control Test, the mean work produced by the paretic leg, and the unbalance in mechanical work between paretic and nonparetic legs during voluntary pedaling. Participants were evaluated before training, after training, and at 3- to 5-month follow-up visits. No significant differences were found between groups at baseline. Repeated-measures ANOVA (P<0.05) revealed significant increases in Motricity Index, Trunk Control Test, Upright Motor Control Test, gait speed, and mean work of the paretic leg after training and at follow-up assessments for FES-treated patients. No outcome measures demonstrated significant improvements after training in the placebo group. Both groups showed no significant differences between assessments after training and at follow-up. A main effect favoring FES-treated patients was demonstrated by repeated-measures ANCOVA for Motricity Index (P<0.001), Trunk Control Test (P=0.001), Upright Motor Control Test (P=0.005), and pedaling unbalance (P=0.038). The study demonstrated that 20 sessions of FES cycling training significantly improved lower extremity motor functions and accelerated the recovery of overground locomotion in postacute hemiparetic patients. Improvements were maintained at follow-up.

  10. Genetic ablation of the GluK4 kainate receptor subunit causes anxiolytic and antidepressant-like behavior in mice.

    PubMed

    Catches, Justin S; Xu, Jian; Contractor, Anis

    2012-03-17

    There is a clear link between dysregulation of glutamatergic signaling and mood disorders. Genetic variants in the glutamate receptor gene GRIK4, which encodes the kainate receptor subunit GluK4, alter the susceptibility for depression, bipolar disorder and schizophrenia. Here we demonstrate that Grik4(-/-) mice have reduced anxiety and an antidepressant-like phenotype. In the elevated zero-maze, a test for anxiety and risk taking behavior, Grik4(-/-) mice spent significantly more time exploring the open areas of the maze. In anxiogenic tests of marble-burying and novelty-induced suppression of feeding, anxiety-like behavior was consistently reduced in knockout animals. In the forced swim test, a test of learned helplessness that is used to determine depression-like behavior, knockout mice demonstrated significantly less immobility suggesting that Grik4 ablation has an antidepressant-like effect. Finally, in the sucrose preference test, a test for anhedonia in rodents, Grik4(-/-) mice demonstrated increased sucrose preference. Expression of the GluK4 receptor subunit in the forebrain is restricted to the CA3 region of the hippocampus and dentate gyrus regions where KARs are known to modulate synaptic plasticity. We tested whether Grik4 ablation had effects on mossy fiber (MF) plasticity and found there to be a significant impairment in LTP likely through a loss of KAR modulation of excitability of the presynaptic MF axons. These studies demonstrate a clear anxiolytic and antidepressant phenotype associated with ablation of Grik4 and a parallel disruption in hippocampal plasticity, providing support for the importance of this receptor subunit in mood disorders. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Genetic ablation of the GluK4 kainate receptor subunit causes anxiolytic and antidepressant-like behavior in mice

    PubMed Central

    Catches, Justin S.; Xu, Jian; Contractor, Anis

    2012-01-01

    There is a clear link between dysregulation of glutamatergic signaling and mood disorders. Genetic variants in the glutamate receptor gene GRIK4, which encodes the kainate receptor subunit GluK4, alter the susceptibility for depression, bipolar disorder and schizophrenia. Here we demonstrate that Grik4−/− mice have reduced anxiety and an antidepressant-like phenotype. In the elevated zero-maze, a test for anxiety and risk taking behavior, Grik4−/− mice spent significantly more time exploring the open areas of the maze. In anxiogenic tests of marble-burying and novelty-induced suppression of feeding, anxiety-like behavior was consistently reduced in knockout animals. In the forced swim test, a test of learned helplessness that is used to determine depression-like behavior, knockout mice demonstrated significantly less immobility suggesting that Grik4 ablation has an antidepressant-like effect. Finally, in the sucrose preference test, a test for anhedonia in rodents, Grik4−/− mice demonstrated increased sucrose preference. Expression of the GluK4 receptor subunit in the forebrain is restricted to the CA3 region of the hippocampus and dentate gyrus regions where KARs are known to modulate synaptic plasticity. We tested whether Grik4 ablation had effects on mossy fiber (MF) plasticity and found there to be a significant impairment in LTP likely through a loss of KAR modulation of excitability of the presynaptic MF axons. These studies demonstrate a clear anxiolytic and antidepressant phenotype associated with ablation of Grik4 and a parallel disruption in hippocampal plasticity, providing support for the importance of this receptor subunit in mood disorders. PMID:22203159

  12. Comparison of Anxiety Management Training and Self-Control Desensitization.

    ERIC Educational Resources Information Center

    Deffenbacher, Jerry L.; And Others

    1980-01-01

    Anxiety management training and self-control desensitization effectively reduced debilitating test anxiety and increased facilitating test anxiety. Follow-up demonstrated maintenance of debilitating test anxiety reduction. Subjects receiving treatment had significantly higher psychology grades. (Author)

  13. An Investigation of Dental Luting Cement Solubility as a Function of the Marginal Gap.

    DTIC Science & Technology

    1988-05-01

    way ANOVA for the Phase 1 Diffusion Study revealed that there were statistically significant differences between the test groups. A Duncan’s Multiple...cement. The 25, 50, and 75 micron groups demonstrated no statistically significant differences in the amount of remaining luting cement. ( p< 0.05) A...one-way ANOVA was also performed on Phase 2 Dynamic Study. This test revealed that there were statistically significant differences among the test

  14. Central Atlantic Regional Ecological Test Site (CARETS): A prototype regional environmental information system

    NASA Technical Reports Server (NTRS)

    Alexander, R. H. (Principal Investigator)

    1973-01-01

    The author has identified the following significant results. Accomplishments have included: (1) completion of the research design for the USGS/CARETS demonstration project; (2) preparation of photomossics and land use maps at a scale of 1:100,000 for entire area; (3) demonstration of the feasibility of extracting several categories of land use information from ERTS-1 MSS data for a portion of the CARETS region; (4) demonstration of the feasibility of detecting some significant land use changes on ERTS-1 imagery; (5) demonstration of the feasibility of attaching environmental impact significance to the remote sensor-derived land use data; (6) delivery of land use information derived from high altitude aircraft data to the Maryland state planning agency for use in its statewide land use inventory; (7) demonstration of high interest by other use groups in the test region in products and services provided by investigation; and (8) determination of the viability of setting up a computerized geographic information system as part of the CARETS investigation, to facilitate handling of sensor-derived land use data in a variety of formats to suit user requirements.

  15. Investigating the relationship between foveal morphology and refractive error in a population with infantile nystagmus syndrome.

    PubMed

    Healey, Natasha; McLoone, Eibhlin; Mahon, Gerald; Jackson, A Jonathan; Saunders, Kathryn J; McClelland, Julie F

    2013-04-26

    We explored associations between refractive error and foveal hypoplasia in infantile nystagmus syndrome (INS). We recruited 50 participants with INS (albinism n = 33, nonalbinism infantile nystagmus [NAIN] n = 17) aged 4 to 48 years. Cycloplegic refractive error and logMAR acuity were obtained. Spherical equivalent (SER), most ametropic meridian (MAM) refractive error, and better eye acuity (VA) were used for analyses. High resolution spectral-domain optical coherence tomography (SD-OCT) was used to obtain foveal scans, which were graded using the Foveal Hypoplasia Grading Scale. Associations between grades of severity of foveal hypoplasia, and refractive error and VA were explored. Participants with more severe foveal hypoplasia had significantly higher MAMs and SERs (Kruskal-Wallis H test P = 0.005 and P = 0.008, respectively). There were no statistically significant associations between foveal hypoplasia and cylindrical refractive error (Kruskal-Wallis H test P = 0.144). Analyses demonstrated significant differences between participants with albinism or NAIN in terms of SER and MAM (Mann-Whitney U test P = 0.001). There were no statistically significant differences between astigmatic errors between participants with albinism and NAIN. Controlling for the effects of albinism, results demonstrated no significant associations between SER, and MAM and foveal hypoplasia (partial correlation P > 0.05). Poorer visual acuity was associated statistically significantly with more severe foveal hypoplasia (Kruskal-Wallis H test P = 0.001) and with a diagnosis of albinism (Mann-Whitney U test P = 0.001). Increasing severity of foveal hypoplasia is associated with poorer VA, reflecting reduced cone density in INS. Individuals with INS also demonstrate a significant association between more severe foveal hypoplasia and increasing hyperopia. However, in the absence of albinism, there is no significant relation between refractive outcome and degree of foveal hypoplasia, suggesting that foveal maldevelopment in isolation does not impair significantly the emmetropization process. It likely is that impaired emmetropization evidenced in the albinism group may be attributed to the whole eye effect of albinism.

  16. Knee Contact Force Asymmetries in Patients Who Failed Return-to-Sport Readiness Criteria 6 Months After Anterior Cruciate Ligament Reconstruction

    PubMed Central

    Gardinier, Emily S.; Di Stasi, Stephanie; Manal, Kurt; Buchanan, Thomas S.; Snyder-Mackler, Lynn

    2015-01-01

    Background After anterior cruciate ligament (ACL) injury, contact forces are decreased in the injured knee when compared with the uninjured knee. The persistence of contact force asymmetries after ACL reconstruction may increase the risk of reinjury and may play an important role in the development of knee osteoarthritis in these patients. Functional performance may also be useful in identifying patients who demonstrate potentially harmful joint contact force asymmetries after ACL reconstruction. Hypothesis Knee joint contact force asymmetries would be present during gait after ACL reconstruction, and performance on a specific set of validated return-to-sport (RTS) readiness criteria would discriminate between those who demonstrated contact force asymmetries and those who did not. Study Design Descriptive laboratory study. Methods A total of 29 patients with ACL ruptures participated in gait analysis and RTS readiness testing 6 months after reconstruction. Muscle and joint contact forces were estimated using an electromyography (EMG)–driven musculoskeletal model of the knee. The magnitude of typical limb asymmetry in uninjured controls was used to define limits of meaningful limb asymmetry in patients after ACL reconstruction. The RTS testing included isometric quadriceps strength testing, 4 unilateral hop tests, and 2 self-report questionnaires. Paired t tests were used to assess limb symmetry for peak medial and tibiofemoral contact forces in all patients, and a mixed-design analysis of variance was used to analyze the effect of passing or failing RTS testing on contact force asymmetry. Results Among all patients, neither statistically significant nor meaningful contact force asymmetries were identified. However, patients who failed RTS testing exhibited meaningful contact force asymmetries, with tibiofemoral contact force being significantly lower for the involved knee. Conversely, patients who passed RTS testing exhibited neither significant nor meaningful contact force asymmetries. Conclusion Joint contact force asymmetries during gait are present in some patients 6 months after ACL reconstruction. Patients who demonstrated poor functional performance on RTS readiness testing exhibited significant and meaningful contact force asymmetries. Clinical Relevance When assessing all patients together, variability in the functional status obscured significant and meaningful differences in contact force asymmetry in patients 6 months after ACL reconstruction. These specific RTS readiness criteria appear to differentiate between those who demonstrate joint contact force symmetry after ACL reconstruction and those who do not. PMID:25318940

  17. Demonstration of Super Cooled Ice as a Phase Change Material Heat Sink for Portable Life Support Systems

    NASA Technical Reports Server (NTRS)

    Leimkuehler, Thomas O.; Bue, Grant C.

    2009-01-01

    A phase change material (PCM) heat sink using super cooled ice as a nontoxic, nonflammable PCM is being developed. The latent heat of fusion for water is approximately 70% larger than most paraffin waxes, which can provide significant mass savings. Further mass reduction is accomplished by super cooling the ice significantly below its freezing temperature for additional sensible heat storage. Expansion and contraction of the water as it freezes and melts is accommodated with the use of flexible bag and foam materials. A demonstrator unit has been designed, built, and tested to demonstrate proof of concept. Both testing and modeling results are presented along with recommendations for further development of this technology.

  18. A Performance Comparison of Color Vision Tests for Military Screening.

    PubMed

    Walsh, David V; Robinson, James; Jurek, Gina M; Capó-Aponte, José E; Riggs, Daniel W; Temme, Leonard A

    2016-04-01

    Current color vision (CV) tests used for aviation screening in the U.S. Army only provide pass-fail results, and previous studies have shown variable sensitivity and specificity. The purpose of this study was to evaluate seven CV tests to determine an optimal CV test screener that potentially could be implemented by the U.S. Army. There were 133 subjects [65 Color Vision Deficits (CVD), 68 Color Vision Normal (CVN)] who performed all of the tests in one setting. CVD and CVN determination was initially assessed with the Oculus anomaloscope. Each test was administered monocularly and according to the test protocol. The main outcome measures were test sensitivity, specificity, and administration time (automated tests). Three of the four Pseudoisochromatic Plate (PIP) tests had a sensitivity/specificity > 0.90 OD/OS, whereas the FALANT tests had a sensitivity/specificity > 0.80 OD/OS. The Cone Contrast Test (CCT) demonstrated sensitivity/specificity > 0.90 OD/OS, whereas the Color Assessment and Diagnosis (CAD) test demonstrated sensitivity/specificity > 0.85 OD/OS. Comparison with the anomaloscope ("gold standard") revealed no significant difference of sensitivity and specificity OD/OS with the CCT, Dvorine PIP, and PIPC tests. Finally, the CCT administration time was significantly faster than the CAD test. The current U.S. Army CV screening tests demonstrated good sensitivity and specificity, as did the automated tests. In addition, some current PIP tests (Dvorine, PIPC), and the CCT performed no worse statistically than the anomaloscope with regard to sensitivity/specificity. The CCT letter presentation is randomized and results would not be confounded by potential memorization, or fading, of book plates.

  19. Treatment of Test Anxiety by Cue-Controlled Desensitization and Study-Skills Training.

    ERIC Educational Resources Information Center

    Lent, Robert W.; Russell, Richard K.

    1978-01-01

    Compared relative effectiveness of two multicomponent strategies in the treatment of test anxiety. Test-anxious students were assigned to groups. Within-group changes between pre- and post-testing favored multicomponent treatments. Between groups, both desensitization treatment programs demonstrated significant improvement over no-treatment on…

  20. Use and effect of clinical photographic records on the motivation and oral hygiene practices of a group of mentally handicapped adults.

    PubMed

    Bickley, S R; Shaw, L; Shaw, M J

    1990-01-01

    A study was undertaken to test the hypothesis that clinical photographic records can be used to motivate oral hygiene performance in mentally handicapped adults. Plaque reduction over the period of the study was shown to be higher in the test group than the control group but differences between the test and control groups were not statistically significant. The small numbers involved (29) and the difficulties in matching subjects may have mitigated against demonstrating a statistically significant difference between the two groups. All participants demonstrated high levels of toothbrushing ability during the practical aspects of the study but this was not maintained through daily oral hygiene practices in the majority of subjects.

  1. Effect of computer-aided instruction versus traditional modes on student PT's learning musculoskeletal special tests

    NASA Astrophysics Data System (ADS)

    Ford, Gregory Scott

    2007-12-01

    Title. Effect of computer-aided instruction versus traditional modes on student PT's learning musculoskeletal special tests. Problem. Lack of quantitative evidence to support the use of computer-aided instruction (CAI) in PT education for both the cognitive and psychomotor domains and lack of qualitative support as to an understanding why CAI may or may not be effective. Design. 3 group single-blind pre-test, immediate post-test, final post-test repeated measures with qualitative survey for the CAI group. Methods. Subjects were randomly assigned to CAI, live demonstration or textbook learning groups. Three novel special tests were instructed. Analysis of performance on written and practical examinations was conducted across the 3 repeated measures. A qualitative survey was completed by the CAI group post intervention. Results. CAI is equally as effective as live demonstration and textbook learning of musculoskeletal special tests in the cognitive domain, however, CAI was superior to live demonstration and textbook instruction at final post-testing. Significance. The significance of this research is that a gap in the literature of PT education needs to be bridged as it pertains to the effect of CAI on learning in both the cognitive and psychomotor domains as well as attempt to understand why CAI results in certain student performance. The methods of this study allowed for a wide range of generalizability to any and all PT programs across the country.

  2. Double-blind, placebo-controlled immunotherapy with mixed grass-pollen allergoids. II. Comparison between parameters assessing the efficacy of immunotherapy.

    PubMed

    Bousquet, J; Maasch, H; Martinot, B; Hejjaoui, A; Wahl, R; Michel, F B

    1988-09-01

    Specific immunotherapy is effective in alleviating symptoms in grass pollen-induced rhinitis, but there are no clear data demonstrating a correlation between symptom-medication scores and objective parameters. Twenty-five patients taking part in a double-blind, placebo-controlled immunotherapy with mixed grass pollen-formalinized allergoids were studied. All patients had the same investigations. Symptom-medication scores were significantly (p less than 0.005, Mann-Whitney U test) reduced in the treated group by comparison to the placebo-treated patients. Nasal challenges performed with threefold increasing numbers of orchard grass-pollen grains demonstrated that patients treated with allergoid tolerated a significantly (p less than 0.005, Wilcoxon W test) greater number of grains after treatment, whereas there was no mean difference in the placebo-treated patients. There was a significant (p less than 0.005, Spearman rank-correlation) correlation between nasal challenges and symptom scores during the season. The skin prick test end point was significantly (p less than 0.001, Wilcoxon W test) reduced after treatment in the allergoid-treated group and remained unchanged in the placebo-treated group. There was a significant (p less than 0.001) correlation between the skin prick test end point and symptom scores during the season. Serum grass-pollen IgG titrated by a solid-phase radioimmunoassay with Staphylococcus A protein was significantly (p less than 0.01, Wilcoxon W test) increased after treatment with allergoid, but there was no significant correlation between IgG titer and symptom scores during the season. Serum grass-pollen IgE increased (p less than 0.04, Wilcoxon W test) in the treated group but there was no correlation with symptom scores.

  3. Space Station propulsion - Advanced development testing of the water electrolysis concept at MSFC

    NASA Technical Reports Server (NTRS)

    Jones, Lee W.; Bagdigian, Deborah R.

    1989-01-01

    The successful demonstration at Marshall Space Flight Center (MSFC) that the water electrolysis concept is sufficiently mature to warrant adopting it as the baseline propulsion design for Space Station Freedom is described. In particular, the test results demonstrated that oxygen/hydrogen thruster, using gaseous propellants, can deliver more than two million lbf-seconds of total impulse at mixture ratios of 3:1 to 8:1 without significant degradation. The results alao demonstrated succcessful end-to-end operation of an integrated water electrolysis propulsion system.

  4. Ground test for vibration control demonstrator

    NASA Astrophysics Data System (ADS)

    Meyer, C.; Prodigue, J.; Broux, G.; Cantinaud, O.; Poussot-Vassal, C.

    2016-09-01

    In the objective of maximizing comfort in Falcon jets, Dassault Aviation is developing an innovative vibration control technology. Vibrations of the structure are measured at several locations and sent to a dedicated high performance vibration control computer. Control laws are implemented in this computer to analyse the vibrations in real time, and then elaborate orders sent to the existing control surfaces to counteract vibrations. After detailing the technology principles, this paper focuses on the vibration control ground demonstration that was performed by Dassault Aviation in May 2015 on Falcon 7X business jet. The goal of this test was to attenuate vibrations resulting from fixed forced excitation delivered by shakers. The ground test demonstrated the capability to implement an efficient closed-loop vibration control with a significant vibration level reduction and validated the vibration control law design methodology. This successful ground test was a prerequisite before the flight test demonstration that is now being prepared. This study has been partly supported by the JTI CleanSky SFWA-ITD.

  5. Summary of Rocketdyne Engine A5 Rocket Based Combined Cycle Testing

    NASA Technical Reports Server (NTRS)

    Ketchum. A.; Emanuel, Mark; Cramer, John

    1998-01-01

    Rocketdyne Propulsion and Power (RPP) has completed a highly successful experimental test program of an advanced rocket based combined cycle (RBCC) propulsion system. The test program was conducted as part of the Advanced Reusable Technology program directed by NASA-MSFC to demonstrate technologies for low-cost access to space. Testing was conducted in the new GASL Flight Acceleration Simulation Test (FAST) facility at sea level (Mach 0), Mach 3.0 - 4.0, and vacuum flight conditions. Significant achievements obtained during the test program include 1) demonstration of engine operation in air-augmented rocket mode (AAR), ramjet mode and rocket mode and 2) smooth transition from AAR to ramjet mode operation. Testing in the fourth mode (scramjet) is scheduled for November 1998.

  6. Influence of upper-body external loading on anaerobic exercise performance.

    PubMed

    Inacio, Mario; Dipietro, Loretta; Visek, Amanda J; Miller, Todd A

    2011-04-01

    The purpose of this study was to assess the threshold where simulated adipose tissue weight gain significantly affects performance in common anaerobic tasks and determine whether differences exist between men and women. Forty-six subjects (men = 21; women = 25) were tested for vertical jump, 20- and 40-yd dash, and 20-yd shuttle tests under 6 different loading conditions (0, 2, 4, 6, 8, and 10% of added body weight). Results were compared to each subject's baseline values (0% loading condition). Results demonstrate significant decrements in performance, starting at the 2% loading condition, for both genders, in every performance test (p < 0.05). On average, subjects jumped 4.91 ± 0.29 to 9.83 ± 0.30 cm less, increased agility test times from 5.49 ± 0.56 to 5.86 ± 0.61 seconds, and increased sprint times from 7.80 ± 0.96 to 8.39 ± 1.07 seconds (2-10%, respectively; p < 0.05). When lower-body power was corrected for total body mass, men exerted significantly more power than women did in every loading condition. Conversely, when lower-body power was corrected for lean body mass, men exerted significantly more power than did women only at the 2% loading condition. This study demonstrates that for the specific anaerobic performance tests performed, increases in external loading as low as 2% of body weight results in significant decreases in performance. Moreover, for these specific tests, men and women tend to express the same threshold in performance decrements.

  7. Inter-Rater Reliability and Validity of the Australian Football League’s Kicking and Handball Tests

    PubMed Central

    Cripps, Ashley J.; Hopper, Luke S.; Joyce, Christopher

    2015-01-01

    Talent identification tests used at the Australian Football League’s National Draft Combine assess the capacities of athletes to compete at a professional level. Tests created for the National Draft Combine are also commonly used for talent identification and athlete development in development pathways. The skills tests created by the Australian Football League required players to either handball (striking the ball with the hand) or kick to a series of 6 randomly generated targets. Assessors subjectively rate each skill execution giving a 0-5 score for each disposal. This study aimed to investigate the inter-rater reliability and validity of the skills tests at an adolescent sub-elite level. Male Australian footballers were recruited from sub-elite adolescent teams (n = 121, age = 15.7 ± 0.3 years, height = 1.77 ± 0.07 m, mass = 69.17 ± 8.08 kg). The coaches (n = 7) of each team were also recruited. Inter-rater reliability was assessed using Inter-class correlations (ICC) and Limits of Agreement statistics. Both the kicking (ICC = 0.96, p < .01) and handball tests (ICC = 0.89, p < .01) demonstrated strong reliability and acceptable levels of absolute agreement. Content validity was determined by examining the test scores sensitivity to laterality and distance. Concurrent validity was assessed by comparing coaches’ perceptions of skill to actual test outcomes. Multivariate analysis of variance (MANOVA) examined the main effect of laterality, with scores on the dominant hand (p = .04) and foot (p < .01) significantly higher compared to the non-dominant side. Follow-up univariate analysis reported significant differences at every distance in the kicking test. A poor correlation was found between coaches’ perceptions of skill and testing outcomes. The results of this study demonstrate both skill tests demonstrate acceptable inter-rater reliable. Partial content validity was confirmed for the kicking test, however further research is required to confirm validity of the handball test. Key points The skill tests created by the AFL demonstrated acceptable levels of relative and absolute inter-rater reliability. Both the AFL’s skills tests are able to differentiate between athletes dominant and non-dominant limbs. However, only the kicking test could consistently differentiated between score outcomes over a range of Australian Football specific disposal distances. Both tests demonstrated poor concurrent validity, with no correlation found between coaches’ perceptions of technical skills and actual skill outcomes measured. PMID:26336356

  8. Significance testing of clinical data using virus dynamics models with a Markov chain Monte Carlo method: application to emergence of lamivudine-resistant hepatitis B virus.

    PubMed Central

    Burroughs, N J; Pillay, D; Mutimer, D

    1999-01-01

    Bayesian analysis using a virus dynamics model is demonstrated to facilitate hypothesis testing of patterns in clinical time-series. Our Markov chain Monte Carlo implementation demonstrates that the viraemia time-series observed in two sets of hepatitis B patients on antiviral (lamivudine) therapy, chronic carriers and liver transplant patients, are significantly different, overcoming clinical trial design differences that question the validity of non-parametric tests. We show that lamivudine-resistant mutants grow faster in transplant patients than in chronic carriers, which probably explains the differences in emergence times and failure rates between these two sets of patients. Incorporation of dynamic models into Bayesian parameter analysis is of general applicability in medical statistics. PMID:10643081

  9. Another Look at the Power of Meta-Analysis in the Solomon Four-Group Design.

    ERIC Educational Resources Information Center

    Sawilowsky, Shlomo S.; Markman, Barry S.

    This paper demonstrates that a meta-analysis technique applied to the Solomon Four-Group Design (SFGD) can fail to find significance even though an earlier "weaker" test may have found significance. The meta-analysis technique was promoted by Braver and Braver as the most powerful single test for analyzing data from an SFGD. They…

  10. Treatment of Test Anxiety by Cue-Controlled Relaxation and Systematic Desensitization

    ERIC Educational Resources Information Center

    Russell, Richard K.; And Others

    1976-01-01

    Test-anxious subjects (N=19) participated in an outcome study comparing systematic desensitization, cue-controlled relaxation, and no treatment. The treatment groups demonstrated significant improvement on the self-report measures of test and state anxiety but not on the behavioral indices. The potential advantages of this technique over…

  11. Manual unloading of the lumbar spine: can it identify immediate responders to mechanical traction in a low back pain population? A study of reliability and criterion referenced predictive validity

    PubMed Central

    Swanson, Brian T.; Riley, Sean P.; Cote, Mark P.; Leger, Robin R.; Moss, Isaac L.; Carlos,, John

    2016-01-01

    Background To date, no research has examined the reliability or predictive validity of manual unloading tests of the lumbar spine to identify potential responders to lumbar mechanical traction. Purpose To determine: (1) the intra and inter-rater reliability of a manual unloading test of the lumbar spine and (2) the criterion referenced predictive validity for the manual unloading test. Methods Ten volunteers with low back pain (LBP) underwent a manual unloading test to establish reliability. In a separate procedure, 30 consecutive patients with LBP (age 50·86±11·51) were assessed for pain in their most provocative standing position (visual analog scale (VAS) 49·53±25·52 mm). Patients were assessed with a manual unloading test in their most provocative position followed by a single application of intermittent mechanical traction. Post traction, pain in the provocative position was reassessed and utilized as the outcome criterion. Results The test of unloading demonstrated substantial intra and inter-rater reliability K = 1·00, P = 0·002, K = 0·737, P = 0·001, respectively. There were statistically significant within group differences for pain response following traction for patients with a positive manual unloading test (P<0·001), while patients with a negative manual unloading test did not demonstrate a statistically significant change (P>0·05). There were significant between group differences for proportion of responders to traction based on manual unloading response (P = 0·031), and manual unloading response demonstrated a moderate to strong relationship with traction response Phi = 0·443, P = 0·015. Discussion and conclusion The manual unloading test appears to be a reliable test and has a moderate to strong correlation with pain relief that exceeds minimal clinically important difference (MCID) following traction supporting the validity of this test. PMID:27559274

  12. Color Stability of New Esthetic Restorative Materials: A Spectrophotometric Analysis

    PubMed Central

    Vialba, Lodovico; Federico, Ricaldone; Colombo, Marco; Beltrami, Riccardo

    2017-01-01

    The aim of this in vitro study was to evaluate and compare the color stability of different esthetic restorative materials (one microfilled composite, one nanofilled composite, one nanoceramic composite, one microfilled hybrid composite, one microfilled hybrid composite, one nanohybrid Ormocer based composite and one supra-nano spherical hybrid composite) after exposure to different staining solutions (physiological saline, red wine, coffee). All materials were prepared and polymerized into silicon rings (2 mm × 6 mm × 8 mm) to obtain specimens identical in size. Thirty cylindrical specimens of each material were prepared. Specimens were immersed in staining solutions (physiological saline, coffee and red wine) over a 28-day test period. A colorimetric evaluation according to the CIE L*a*b* system was performed by a blind trained operator at 7, 14, 21, 28 days of the staining process. The Shapiro–Wilk test and ANOVA were applied to assess significant differences among restorative materials. A paired t-test was applied to test which CIE L*a*b* parameters significantly changed after immersion in staining solutions. All restorative materials showed significant color differences after immersion in coffee. Coffee caused a significant color change in all types of tested composite resins. Only Filtek Supreme XTE demonstrated a staining susceptibility to red wine; no other significant differences among the materials were demonstrated. Long-term exposure to some food dyes (coffee in particular) can significantly affect the color stability of modern esthetic restorative materials regardless of materials’ different compositions. PMID:28684672

  13. Color Stability of New Esthetic Restorative Materials: A Spectrophotometric Analysis.

    PubMed

    Poggio, Claudio; Vialba, Lodovico; Berardengo, Anna; Federico, Ricaldone; Colombo, Marco; Beltrami, Riccardo; Scribante, Andrea

    2017-07-06

    The aim of this in vitro study was to evaluate and compare the color stability of different esthetic restorative materials (one microfilled composite, one nanofilled composite, one nanoceramic composite, one microfilled hybrid composite, one microfilled hybrid composite, one nanohybrid Ormocer based composite and one supra-nano spherical hybrid composite) after exposure to different staining solutions (physiological saline, red wine, coffee). All materials were prepared and polymerized into silicon rings (2 mm × 6 mm × 8 mm) to obtain specimens identical in size. Thirty cylindrical specimens of each material were prepared. Specimens were immersed in staining solutions (physiological saline, coffee and red wine) over a 28-day test period. A colorimetric evaluation according to the CIE L*a*b* system was performed by a blind trained operator at 7, 14, 21, 28 days of the staining process. The Shapiro-Wilk test and ANOVA were applied to assess significant differences among restorative materials. A paired t -test was applied to test which CIE L*a*b* parameters significantly changed after immersion in staining solutions. All restorative materials showed significant color differences after immersion in coffee. Coffee caused a significant color change in all types of tested composite resins. Only Filtek Supreme XTE demonstrated a staining susceptibility to red wine; no other significant differences among the materials were demonstrated. Long-term exposure to some food dyes (coffee in particular) can significantly affect the color stability of modern esthetic restorative materials regardless of materials' different compositions.

  14. The Relationship between Deductive Reasoning Ability, Test Anxiety, and Standardized Test Scores in a Latino Sample

    ERIC Educational Resources Information Center

    Rich, John D., Jr.; Fullard, William; Overton, Willis

    2011-01-01

    One Hundred and Twelve Latino students from Philadelphia participated in this study, which examined the development of deductive reasoning across adolescence, and the relation of reasoning to test anxiety and standardized test scores. As predicted, 11th and ninth graders demonstrated significantly more advanced reasoning than seventh graders.…

  15. NASA Rat Acoustic Tolerance Test 1994-1995: 8 kHz, 16 kHz, 32 kHz Experiments

    NASA Technical Reports Server (NTRS)

    Mele, Gary D.; Holley, Daniel C.; Naidu, Sujata

    1996-01-01

    Adult male Sprague-Dawley rats were exposed to chronic applied sound (74 to 79 dB, SPL) with octave band center frequencies of either 8, 16 or 32 kHz for up to 60 days. Control cages had ambient sound levels of about 62 dB (SPL). Groups of rats (test vs. control; N=9 per group) were euthanized after 0. 5. 14, 30, and 60 days. On each euthanasia day, objective evaluation of their physiology and behavior was performed using a Stress Assessment Battery (SAB) of measures. In addition, rat hearing was assessed using the brain stem auditory evoked potential (BAER) method after 60 days of exposure. No statistically significant differences in mean daily food use could be attributed to the presence of the applied test sound. Test rats used 5% more water than control rats. In the 8 kHz and 32 kHz tests this amount was statistically significant(P less than .05). This is a minor difference of questionable physiological significance. However, it may be an indication of a small reaction to the constant applied sound. Across all test frequencies, day 5 test rats had 6% larger spleens than control rats. No other body or organ weight differences were found to be statistically significant with respect to the application of sound. This spleen effect may be a transient adaptive process related to adaptation to the constant applied noise. No significant test effect on differential white blood cell counts could be demonstrated. One group demonstrated a low eosinophil count (16 kHz experiment, day 14 test group). However this was highly suspect. Across all test frequencies studied, day 5 test rats had 17% fewer total leukocytes than day 5 control rats. Sound exposed test rats exhibited 44% lower plasma corticosterone concentrations than did control rats. Note that the plasma corticosterone concentration was lower in the sound exposed test animals than the control animals in every instance (frequency exposure and number of days exposed).

  16. An evaluation of the Shirley Highway Express-Bus-on-Freeway Demonstration Project.

    DOT National Transportation Integrated Search

    1973-01-01

    The Shirley Highway Express-Bus-on-Freeway Demonstration Project was initiated to test the hypothesis that the provision of rapid and convenient bus service over an exclusive lane would attract significant numbers of automobile passengers. Such a div...

  17. Post-test evaluation of the geology, geochemistry, microbiology, and hydrology of the in situ air stripping demonstration site at the Savannah River Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eddy Dilek, C.A.; Looney, B.B.; Hazen, T.C.

    A full-scale demonstration of the use of horizontal wells for in situ air stripping for environment restoration was completed as part of the Savannah River Integrated Demonstration Program. The demonstration of in situ air stripping was the first in a series of demonstrations of innovative remediation technologies for the cleanup of sites contaminated with volatile organic contaminants. The in situ air stripping system consisted of two directionally drilled wells that delivered gases to and extract contamination from the subsurface. The demonstration was designed to remediate soils and sediments in the unsaturated and saturated zones as well as groundwater contaminated withmore » volatile organic compounds. The demonstration successfully removed significant quantities of solvent from the subsurface. The field site and horizontal wells were subsequently used for an in situ bioremediation demonstration during which methane was added to the injected air. The field conditions documented herein represent the baseline status of the site for evaluating the in situ bioremediation as well as the post-test conditions for the in situ air stripping demonstration. Characterization activities focused on documenting the nature and distribution of contamination in the subsurface. The post-test characterization activities discussed herein include results from the analysis of sediment samples, three-dimensional images of the pretest and post-test data, contaminant inventories estimated from pretest and post-test models, a detailed lithologic cross sections of the site, results of aquifer testing, and measurements of geotechnical parameters of undisturbed core sediments.« less

  18. Demonstration of Mer-Cure Technology for Enhanced Mercury Control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    John Marion; Dave O'Neill; Kevin Taugher

    2008-06-01

    Alstom Power Inc. has completed a DOE/NETL-sponsored program (under DOE Cooperative Agreement No. De-FC26-07NT42776) to demonstrate Mer-Cure{trademark}, one of Alstom's mercury control technologies for coal-fired boilers. The Mer-Cure{trademark}system utilizes a small amount of Mer-Clean{trademark} sorbent that is injected into the flue gas stream for oxidation and adsorption of gaseous mercury. Mer-Clean{trademark} sorbents are carbon-based and prepared with chemical additives that promote oxidation and capture of mercury. The Mer-Cure{trademark} system is unique in that the sorbent is injected into an environment where the mercury capture kinetics is accelerated. The full-scale demonstration program originally included test campaigns at two host sites: LCRA's 480-MW{sub e} Fayette Unit No.3 and Reliant Energy's 190-MW{sub e} Shawville Unit No.3. The only demonstration tests actually done were the short-term tests at LCRA due to budget constraints. This report gives a summary of the demonstration testing at Fayette Unit No.3. The goals for this Mercury Round 3 program, established by DOE/NETL under the original solicitation, were to reduce the uncontrolled mercury emissions by 90% at a cost significantly less than 50% of the previous target ofmore » $$60,000/lb mercury removed. The results indicated that Mer-Cure{trademark} technology could achieve mercury removal of 90% based on uncontrolled stack emissions. The estimated costs for 90% mercury control, at a sorbent cost of $$0.75 to $2.00/lb respectively, were $13,400 to $18,700/lb Hg removed. In summary, the results from demonstration testing show that the goals established by DOE/NETL were met during this test program. The goal of 90% mercury reduction was achieved. Estimated mercury removal costs were 69-78% lower than the benchmark of $60,000/lb mercury removed, significantly less than 50% of the baseline removal cost.« less

  19. TEXSYS. [a knowledge based system for the Space Station Freedom thermal control system test-bed

    NASA Technical Reports Server (NTRS)

    Bull, John

    1990-01-01

    The Systems Autonomy Demonstration Project has recently completed a major test and evaluation of TEXSYS, a knowledge-based system (KBS) which demonstrates real-time control and FDIR for the Space Station Freedom thermal control system test-bed. TEXSYS is the largest KBS ever developed by NASA and offers a unique opportunity for the study of technical issues associated with the use of advanced KBS concepts including: model-based reasoning and diagnosis, quantitative and qualitative reasoning, integrated use of model-based and rule-based representations, temporal reasoning, and scale-up performance issues. TEXSYS represents a major achievement in advanced automation that has the potential to significantly influence Space Station Freedom's design for the thermal control system. An overview of the Systems Autonomy Demonstration Project, the thermal control system test-bed, the TEXSYS architecture, preliminary test results, and thermal domain expert feedback are presented.

  20. Assessment of behavioral mechanisms maintaining encopresis: Virginia Encopresis-Constipation Apperception Test.

    PubMed

    Cox, Daniel J; Ritterband, Lee M; Quillian, Warren; Kovatchev, Boris; Morris, James; Sutphen, James; Borowitz, Stephen

    2003-09-01

    To develop and test a scale for parent and child, evaluating theoretical and clinical parameters relevant to children with encopresis. Encopretic children were hypothesized to have more bowel-specific, but not more generic, psychological problems, as compared with nonsymptomatic control children. In addition, mothers were also believed to be more discerning than children. The Virginia Encopresis-Constipation Apperception Test (VECAT) consists of 9 pairs of bowel-specific and 9 parallel generic drawings. Respondents selected the picture in each pair that best described them/their child. It was administered to encopretic children (N = 87), nonsymptomatic siblings (N = 27), and nonsymptomatic nonsiblings (N = 35). The mothers of all the participants also completed the VECAT. Encopretic children were retested 6 and 12 months posttreatment with Enhanced Toilet Training. The VECAT demonstrated good test-retest reliability and internal consistency. Encopretic children and their mothers reported more bowel-specific, but not more generic, problems. Bowel-specific scores improved significantly posttreatment only for those patients who demonstrated significant symptom improvement. Mothers were significantly more discerning than children. The VECAT is a reliable, valid, discriminating, and sensitive test. Bowel-specific problems appear to best differentiate children with and without encopresis.

  1. Concussion in professional football: neuropsychological testing--part 6.

    PubMed

    Pellman, Elliot J; Lovell, Mark R; Viano, David C; Casson, Ira R; Tucker, Andrew M

    2004-12-01

    The National Football League (NFL) neuropsychological testing program is reviewed, and neuropsychological test data are presented on various samples of NFL athletes who sustained concussion (mild traumatic brain injury, MTBI). This study evaluated post-MTBI neuropsychological testing of NFL players from 1996 to 2001. All athletes completed a standardized battery of neuropsychological tests and underwent postinjury neuropsychological testing within a few days after concussion. Test scores were compared with baselines using analysis of variance for athletes having on-field memory dysfunction, three or more concussions, or 7+ days out from practice and play. The MTBI group did not display significant neuropsychological dysfunction relative to baseline scores within a few days of injury. However, a subsample of the injured athletes who displayed on-field memory dysfunction performed significantly more poorly on two of the memory tests. The neuropsychological test results of a group of athletes with a history of three or more MTBIs did not differ significantly compared with a group who had fewer than three concussions or compared with league-wide normative data. The neuropsychological performance of athletes who were out from full participation 7+ days was not significantly different from the group who returned to play within 7 days or the norms. Neuropsychological testing is used within the overall medical evaluation and care of NFL athletes. Players who experience MTBI generally demonstrate rapid recovery of neuropsychological performance, although poorer neuropsychological test results were related to on-field memory dysfunction. NFL players did not demonstrate evidence of neurocognitive decline after multiple (three or more) MTBIs or in those players out 7+ days. The data show that MTBI in this population is characterized by a rapid return of neuropsychological function in the days after injury.

  2. Text Messaging Improves Participation in Laboratory Testing in Adolescent Liver Transplant Patients.

    PubMed

    McKenzie, Rebecca B; Berquist, William E; Foley, Megan A; Park, K T; Windsheimer, Jered E; Litt, Iris F

    In solid organ transplant patients, non-participation in all aspects of the medical regimen is a prevalent problem associated with adverse consequences particularly in the adolescent and young adult (AYA) age group. This study is the first to evaluate the feasibility, utility and impact of a text messaging (TM) intervention to improve participation in laboratory testing in adolescent liver transplant patients. AYA patients, aged 12 to 21 years, were recruited for a prospective pilot trial evaluating a TM intervention delivered over a 1-year period. The intervention involved automated TM reminders with feedback administered according to a prescribed laboratory testing frequency. Participation rate in laboratory testing after the intervention was compared to the year prior. Patient responses and feedback by text and survey were used to assess feasibility, acceptability and use of the intervention. Forty-two patients were recruited and 33 patients remained enrolled for the study duration. Recipients of the TM intervention demonstrated a significant improvement in participation rate in laboratory testing from 58% to 78% (P<.001). This rate was also significantly higher than in non-intervention controls (P=.003). There was a high acceptability, response rate and a significant correlation with reported versus actual completion of laboratory tests by TM. TM reminders significantly improved participation in laboratory testing in AYA liver transplant patients. The intervention demonstrated feasibility, acceptability, and use with a high proportion of patients who engaged in and perceived a benefit from using this technology.

  3. Development and flight test evaluation of a pitch stability augmentation system for a relaxed stability L-1011

    NASA Technical Reports Server (NTRS)

    Rising, J. J.

    1982-01-01

    The L-1011 has been flight tested to demonstrate the relaxed static stability concept as a means of obtaining significant drag benefits to achieve a more energy efficient transport. Satisfactory handling qualities were maintained with the design of an active control horizontal tail for stability and control augmentation to allow operation of the L-1011 at centers of gravity close to the neutral point. Prior to flight test, a motion base visual flight simulator program was performed to optimize the augmentation system. The system was successfully demonstrated in a test program totaling forty-eight actual flight hours.

  4. Experimental investigation of elastic mode control on a model of a transport aircraft

    NASA Technical Reports Server (NTRS)

    Abramovitz, M.; Heimbaugh, R. M.; Nomura, J. K.; Pearson, R. M.; Shirley, W. A.; Stringham, R. H.; Tescher, E. L.; Zoock, I. E.

    1981-01-01

    A 4.5 percent DC-10 derivative flexible model with active controls is fabricated, developed, and tested to investigate the ability to suppress flutter and reduce gust loads with active controlled surfaces. The model is analyzed and tested in both semispan and complete model configuration. Analytical methods are refined and control laws are developed and successfully tested on both versions of the model. A 15 to 25 percent increase in flutter speed due to the active system is demonstrated. The capability of an active control system to significantly reduce wing bending moments due to turbulence is demonstrated. Good correlation is obtained between test and analytical prediction.

  5. A Pilot Study for Evaluation of Digital Systems as an Adjunct to Sphygmomanometry for Undergraduate Teaching

    PubMed Central

    Sharma, Renuka; Kapoor, Raj

    2016-01-01

    Objectives: Blood pressure estimation is a key skill for medical practitioners. It is routinely taught to undergraduate medical students using an aneroid sphygmomanometer. However, the conceptual understanding in the practical remains limited. We conducted the following study to evaluate the efficacy of digital data acquisition systems as an adjunct to the sphygmomanometer to teach blood pressure. Methods: Fifty-seven first-year medical students participated in the study. An MCQ test of 15 questions, consisting of 10 conceptual and five factual questions, was administered twice – pre- and post-demonstration of blood pressure measurement using a digital data acquisition system. In addition, qualitative feedback was also obtained. Results: Median scores were 7 (6 - 8) and 3 (1.5 - 4) in pre-test sessions for conceptual and factual questions, respectively. Post-test scores showed a significant improvement in both categories (10 (9 - 10) and 4 (4 - 4.5), respectively, Mann-Whitney U test, p < 0.0001). Student feedback also indicated that the digital system enhanced learning and student participation. Conclusions: Student feedback regarding the demonstrations was uniformly positive, which was also reflected in significantly improved post-test scores. We conclude that parallel demonstration on digital systems and the sphygmomanometer will enhance student engagement and understanding of blood pressure measurement. PMID:27660735

  6. DEMONSTRATION BULLETIN: SOIL WASHING SYSTEM - BIOTROL, INC.

    EPA Science Inventory

    The three component technologies of the BioTrol Soil Washing System (BSWS). Tested in the SITE demonstration were a Soil Washer (SW), and Aqueous Treatment System (ATS), and a Slurry Bio-Reactor (SBR). The Soil Washer operates on the principle that a significant fraction of the...

  7. EXAMINATIONS AND THE ADVANCEMENT OF TEACHING.

    ERIC Educational Resources Information Center

    BENSON, ARTHUR L.

    FUNCTIONS OF PROFESSIONALLY PREPARED, OBJECTIVE, STANDARDIZED TESTS FOR TEACHERS AND PROSPECTIVE TEACHERS, FOR NATIONWIDE USE, ARE DESCRIBED. THESE ARE (1) ADVANCING THE PRESERVICE PREPARATION OF TEACHERS BY DEMONSTRATING SIGNIFICANT TEST-SCORE DIFFERENCES AMONG STUDENTS FROM VARIOUS INSTITUTIONS, (2) IMPROVING CERTIFICATION OR LICENSING POLICIES…

  8. Cognitive Determinants of Academic Performance in Nigerian Pharmacy Schools.

    PubMed

    Ubaka, Chukwuemeka M; Sansgiry, Sujit S; Ukwe, Chinwe V

    2015-09-25

    Objective. To evaluate cognitive factors that might influence academic performance of students in Nigerian pharmacy schools. Methods. A cross-sectional, multi-center survey of Nigerian pharmacy students from 7 schools of pharmacy was conducted using 2 validated questionnaires measuring cognitive constructs such as test anxiety, academic competence, test competence, time management, and strategic study habits. Results. Female students and older students scored significantly better on time management skills and study habits, respectively. Test anxiety was negatively associated with academic performance while test competence, academic competence, and time management were positively associated with academic performance. These 4 constructs significantly discriminated between the lower and higher performing students, with the first 2 contributing to the most differences. Conclusion. Test and academic competence, test anxiety, and time management were significant factors associated with low and high academic performance among Nigerian pharmacy students. The study also demonstrated the significant effects of age, gender, and marital status on these constructs.

  9. Cognitive Determinants of Academic Performance in Nigerian Pharmacy Schools

    PubMed Central

    Sansgiry, Sujit S.; Ukwe, Chinwe V.

    2015-01-01

    Objective. To evaluate cognitive factors that might influence academic performance of students in Nigerian pharmacy schools. Methods. A cross-sectional, multi-center survey of Nigerian pharmacy students from 7 schools of pharmacy was conducted using 2 validated questionnaires measuring cognitive constructs such as test anxiety, academic competence, test competence, time management, and strategic study habits. Results. Female students and older students scored significantly better on time management skills and study habits, respectively. Test anxiety was negatively associated with academic performance while test competence, academic competence, and time management were positively associated with academic performance. These 4 constructs significantly discriminated between the lower and higher performing students, with the first 2 contributing to the most differences. Conclusion. Test and academic competence, test anxiety, and time management were significant factors associated with low and high academic performance among Nigerian pharmacy students. The study also demonstrated the significant effects of age, gender, and marital status on these constructs. PMID:27168614

  10. Peak oxygen uptake in a sprint interval testing protocol vs. maximal oxygen uptake in an incremental testing protocol and their relationship with cross-country mountain biking performance.

    PubMed

    Hebisz, Rafał; Hebisz, Paulina; Zatoń, Marek; Michalik, Kamil

    2017-04-01

    In the literature, the exercise capacity of cyclists is typically assessed using incremental and endurance exercise tests. The aim of the present study was to confirm whether peak oxygen uptake (V̇O 2peak ) attained in a sprint interval testing protocol correlates with cycling performance, and whether it corresponds to maximal oxygen uptake (V̇O 2max ) determined by an incremental testing protocol. A sample of 28 trained mountain bike cyclists executed 3 performance tests: (i) incremental testing protocol (ITP) in which the participant cycled to volitional exhaustion, (ii) sprint interval testing protocol (SITP) composed of four 30 s maximal intensity cycling bouts interspersed with 90 s recovery periods, (iii) competition in a simulated mountain biking race. Oxygen uptake, pulmonary ventilation, work, and power output were measured during the ITP and SITP with postexercise blood lactate and hydrogen ion concentrations collected. Race times were recorded. No significant inter-individual differences were observed in regards to any of the ITP-associated variables. However, 9 individuals presented significantly increased oxygen uptake, pulmonary ventilation, and work output in the SITP compared with the remaining cyclists. In addition, in this group of 9 cyclists, oxygen uptake in SITP was significantly higher than in ITP. After the simulated race, this group of 9 cyclists achieved significantly better competition times (99.5 ± 5.2 min) than the other cyclists (110.5 ± 6.7 min). We conclude that mountain bike cyclists who demonstrate higher peak oxygen uptake in a sprint interval testing protocol than maximal oxygen uptake attained in an incremental testing protocol demonstrate superior competitive performance.

  11. Racial Differences in Test Preparation Strategies: A Commentary on "Shadow Education, American Style: Test Preparation, the SAT and College Enrollment"

    ERIC Educational Resources Information Center

    Alon, Sigal

    2010-01-01

    Claudia Buchmann, Dennis Condron and Vincent Roscigno's study, titled "Shadow Education, American Style: Test Preparation, the SAT and College Enrollment," demonstrates that vigorous use of expensive test preparation tools, such as private classes and tutors, significantly boosts scores on standardized exams such as the SAT or ACT. This…

  12. Emotional Encoding Context Leads to Memory Bias in Individuals with High Anxiety

    PubMed Central

    Fernandes, Myra A.

    2017-01-01

    We investigated whether anxious individuals, who adopt an inherently negative mindset, demonstrate a particularly salient memory bias for words tainted by negative contexts. To this end, sequentially presented target words, overlayed onto negative or neutral pictures, were studied in separate blocks (within-subjects) using a deep or shallow encoding instruction (between-subjects). Following study, in Test 1, participants completed separate recognition test blocks for the words overlayed onto the negative and the neutral contexts. Following this, in Test 2, participants completed a recognition test for the foils from each Test 1 block. We found a significant three-way interaction on Test 2, such that individuals with high anxiety who initially studied target words using a shallow encoding instruction, demonstrated significantly elevated memory for foils that were contained within the negative Test 1 block. Results show that during retrieval (Test 1), participants re-entered the mode of processing (negative or neutral) engaged at encoding, tainting the encoding of foils with that same mode of processing. The findings suggest that individuals with high relative to low anxiety, adopt a particularly salient negative retrieval mode, and this creates a downstream bias in encoding and subsequent retrieval of otherwise neutral information. PMID:29280957

  13. Emotional Encoding Context Leads to Memory Bias in Individuals with High Anxiety.

    PubMed

    Lee, Christopher; Fernandes, Myra A

    2017-12-27

    We investigated whether anxious individuals, who adopt an inherently negative mindset, demonstrate a particularly salient memory bias for words tainted by negative contexts. To this end, sequentially presented target words, overlayed onto negative or neutral pictures, were studied in separate blocks (within-subjects) using a deep or shallow encoding instruction (between-subjects). Following study, in Test 1, participants completed separate recognition test blocks for the words overlayed onto the negative and the neutral contexts. Following this, in Test 2, participants completed a recognition test for the foils from each Test 1 block. We found a significant three-way interaction on Test 2, such that individuals with high anxiety who initially studied target words using a shallow encoding instruction, demonstrated significantly elevated memory for foils that were contained within the negative Test 1 block. Results show that during retrieval (Test 1), participants re-entered the mode of processing (negative or neutral) engaged at encoding, tainting the encoding of foils with that same mode of processing. The findings suggest that individuals with high relative to low anxiety, adopt a particularly salient negative retrieval mode, and this creates a downstream bias in encoding and subsequent retrieval of otherwise neutral information.

  14. Demonstration of the test-retest reliability and sensitivity of the Lower Limb Functional Index-10 as a measure of functional recovery post burn injury: a cross-sectional repeated measures study design.

    PubMed

    Ryland, Margaret E; Grisbrook, Tiffany L; Wood, Fiona M; Phillips, Michael; Edgar, Dale W

    2016-01-01

    Lower limb burns can significantly delay recovery of function. Measuring lower limb functional outcomes is challenging in the unique burn patient population and necessitates the use of reliable and valid tools. The aims of this study were to examine the test-retest reliability, sensitivity, and internal consistency of Sections 1 and 3 of the Lower Limb Functional Index-10 (LLFI-10) questionnaire for measuring functional ability in patients with lower limb burns over time. Twenty-nine adult patients who had sustained a lower limb burn injury in the previous 12 months completed the test-retest procedure of the study. In addition, the minimal detectable change (MDC) was calculated for Section 1 and 3 of the LLFI-10. Section 1 is focused on the activity limitations experienced by patients with a lower limb disorder whereas Section 3 involves patients indicating their current percentage of pre-injury duties. Section 1 of the LLFI-10 demonstrated excellent test-retest reliability (intra-class correlation coefficient (ICC) 0.98, 95 % CI 0.96-0.99) whilst Section 3 demonstrated high test-retest reliability (ICC 0.88, 95 % CI 0.79-0.94). MDC scores for Sections 1 and 3 were 1.27 points and 30.22 %, respectively. Internal consistency was demonstrated with a significant negative association (r s  = -0.83) between Sections 1 and 3 of the LLFI-10 (p < 0.001). This study demonstrates that Section 1 and 3 of the LLFI-10 are reliable for measuring functional ability in patients who have sustained lower limb burns in the previous 12 months, and furthermore, Section 1 is sensitive to changes in patient function over time.

  15. MECHANICAL INTEGRITY TESTING AND TRAINING FACILITY

    EPA Science Inventory

    Underground injection control regulations of the U.S. Environmental Protection Agency require that all injection wells demonstrate mechanical integrity, which is defined as no significant leak in the casing, tubing or packer, and no significant fluid movement into an underground ...

  16. Physical properties and comparative strength of a bioactive luting cement.

    PubMed

    Jefferies, Steven; Lööf, Jesper; Pameijer, Cornelis H; Boston, Daniel; Galbraith, Colin; Hermansson, Leif

    2013-01-01

    New dental cement formulations require testing to determine physical and mechanical laboratory properties. To test an experimental calcium aluminate/glass-ionomer cement, Ceramir C and B (CC and B), regarding compressive strength (CS), film thickness (FT), net setting time (ST) and Vickers hardness. An additional test to evaluate potential dimensional change/expansion properties of this cement was also conducted. CS was measured according to a slightly modified ISO 9917:2003 for the CC and B specimens. The samples were not clamped while being exposed to relative humidity of great than 90 percent at 37 degrees C for 10 minutes before being stored in phosphate-buffered saline at 37 degrees C. For the CS, four groups were tested: Group 1-CC and B; Group 2-RelyX Luting Cement; Group 3-Fuji Plus; and Group 4-RelyX Unicem. Samples from all groups were stored for 24 hours before testing. Only CCandB was tested for ST and FT according to ISO 9917:2003. The FT was tested 2 minutes after mixing. Vickers hardness was evaluated using the CSM Microhardness Indentation Tester using zinc phosphate cement as a comparison material. Expansion testing included evaluating potential cracks in feldspathic porcelain jacket crowns (PJCs). The mean and standard deviation after 24 hours were expressed in MPa: Group 1 equals 160 plus or equal to 27; Group 2 equals 96 plus or equal to 10; Group 3 equals 138 plus or equal to 15; Group 4 equals 157 plus or equal to 10. A single-factor ANOVA demonstrated statistically significant differences between the groups (P less than 0.001). Pair-wise statistical comparison demonstrated a statistically significant difference between Groups 1 and 2. No statistically significant differences were found between other groups. The FT was 16.8 plus or equal to 0.9 and the ST was 4.8 plus or equal to 0.1 min. Vickers hardness for Ceramir C and B was 68.3 plus or equal to 17.2 and was statistically significantly higher (P less than 0.05) than Fleck's Zinc Phosphate cement at Vickers hardness of 51.4 plus or equal to 10. There was no evidence of cracks due to radial expansion in PJCs by the Ceramir C and B cement. All luting cements tested demonstrated compressive strengths well in excess of the ISO requirement for water-based cements of no less than 50 MPa. Ceramir C and B showed significantly higher CS than RelyX Luting Cement after 24 hours, but was not significantly higher than either Fuji Plus or RelyX Unicem. The ST and FT values of CC and B conform to and are within the boundaries of the requirements of the standard. Surface hardness was statistically higher than and comparable to zinc phosphate cement. There was no evidence of potentially clinically significant and deleterious expansion behavior by this cement. All cements tested demonstrated acceptable strength properties. Within the limits of this study, Ceramir C and B is deemed to possess physical properties suitable for a dental luting cement.

  17. Multicylinder Diesel Engine Tests with Unstabilized Water-in-Fuel Emulsions

    DOT National Transportation Integrated Search

    1981-06-01

    Two diesel engines representative of the four-stroke cycle and two-stroke cycle main propulsion units installed in U.S. Coast Guard WPB class cutters were operated in a test environment in an attempt to demonstrate significant fuel savings associated...

  18. Test-retest reliability and gender differences in the sexual discounting task among cocaine-dependent individuals.

    PubMed

    Johnson, Matthew W; Bruner, Natalie R

    2013-08-01

    The Sexual Discounting Task uses the delay discounting framework to examine sexual HIV risk behavior. Previous research showed task performance to be significantly correlated with self-reported HIV risk behavior in cocaine dependence. Test-retest reliability and gender differences had remained unexamined. The present study examined the test-retest reliability of the Sexual Discounting Task. Cocaine-dependent individuals (18 men, 13 women) completed the task in two laboratory visits ∼7 days apart. Participants selected photographs of individuals with whom they were willing to have casual sex. Among these, participants identified the individual most (and least) likely to have a sexually transmitted infection (STI), and the individual with whom he or she most (and least) wanted to have sex. In reference to these individuals, participants rated their likelihood of having unprotected sex versus waiting to have sex with a condom, at various delays. A money delay discounting task was also completed at the first visit. Significant differences in discounting among partner conditions were shown. Differential stability was demonstrated by significant, positive correlations between test and retest for all four partner conditions. Absolute stability was demonstrated by statistical equivalence tests between test and retest, and also supported by a lack of significant differences between test and retest. Men generally discounted significantly more than women for sexual outcomes but not money. Results suggest the Sexual Discounting Task to be a reliable measure in cocaine-dependent individuals, which supports its use as a repeated measure in clinical research, for example, studies examining acute drug effects on sexual risk and the effects of addiction treatment and HIV prevention interventions on sexual risk. PsycINFO Database Record (c) 2013 APA, all rights reserved

  19. Performance Enhancement of a Full-Scale Vertical Tail Model Equipped with Active Flow Control

    NASA Technical Reports Server (NTRS)

    Whalen, Edward A.; Lacy, Douglas; Lin, John C.; Andino, Marlyn Y.; Washburn, Anthony E.; Graff, Emilio; Wygnanski, Israel J.

    2015-01-01

    This paper describes wind tunnel test results from a joint NASA/Boeing research effort to advance active flow control (AFC) technology to enhance aerodynamic efficiency. A full-scale Boeing 757 vertical tail model equipped with sweeping jet actuators was tested at the National Full-Scale Aerodynamics Complex (NFAC) 40- by 80-Foot Wind Tunnel (40x80) at NASA Ames Research Center. The model was tested at a nominal airspeed of 100 knots and across rudder deflections and sideslip angles that covered the vertical tail flight envelope. A successful demonstration of AFC-enhanced vertical tail technology was achieved. A 31- actuator configuration significantly increased side force (by greater than 20%) at a maximum rudder deflection of 30deg. The successful demonstration of this application has cleared the way for a flight demonstration on the Boeing 757 ecoDemonstrator in 2015.

  20. An Evaluation of the Additional Acoustic Power Needed to Overcome the Effects of a Test-Articles Absorption During Reverberant Chamber Acoustic Testing of Spaceflight Hardware

    NASA Technical Reports Server (NTRS)

    Hozman, Aron D.; Hughes, William O.

    2014-01-01

    It is important to realize that some test-articles may have significant sound absorption that may challenge the acoustic power capabilities of a test facility. Therefore, to mitigate this risk of not being able to meet the customers target spectrum, it is prudent to demonstrate early-on an increased acoustic power capability which compensates for this test-article absorption. This paper describes a concise method to reduce this risk when testing aerospace test-articles which have significant absorption. This method was successfully applied during the SpaceX Falcon 9 Payload Fairing acoustic test program at the NASA Glenn Research Center Plum Brook Stations RATF.

  1. Visual acuity in young elite motorsport athletes: a preliminary report.

    PubMed

    Schneiders, Anthony G; Sullivan, S John; Rathbone, Emma J; Louise Thayer, A; Wallis, Laura M; Wilson, Alexandra E

    2010-05-01

    To determine whether elite motorsport athletes demonstrate superior levels of Visual Acuity than age and sex-matched controls. A cross-sectional observational study. A University vision and balance laboratory. Young male motorsport athletes from the New Zealand Elite Motorsport Academy and healthy age and sex-matched controls. Vision performance tests comprising; Static Visual Acuity (SVA), Dynamic Visual Acuity (DVA), Gaze Stabilization Test (GST), and the Perception Time Test (PTT). Motorsport athletes demonstrated superior visual acuity compared to age and sex-matched controls for all measures, and while this was not statistically significant for SVA, GST and DVA, it reached statistical significance for the PTT (p

  2. Centaur Test Bed (CTB) for Cryogenic Fluid Management

    NASA Technical Reports Server (NTRS)

    Sakla, Steven; Kutter, Bernard; Wall, John

    2006-01-01

    Future missions such as NASA s space exploration vision and DOD satellite servicing will require significant increases in the understanding and knowledge of space based cryogenic fluid management (CFM), including the transfer and storage of cryogenic fluids. Existing CFM capabilities are based on flight of upper stage cryogenic vehicles, scientific dewars, a few dedicated flight demonstrations and ground testing. This current capability is inadequate to support development of the CEV cryogenic propulsion system, other aspects of robust space exploration or the refueling of satellite cryo propulsion systems with reasonable risk. In addition, these technologies can provide significant performance increases for missions beyond low-earth orbit to enable manned missions to the Moon and beyond. The Centaur upper-stage vehicle can provide a low cost test platform for performing numerous flight demonstrations of the full breadth of required CFM technologies to support CEV development. These flight demonstrations can be performed as secondary mission objectives using excess LH2 and/or LO2 from the main vehicle propellant tanks following primary spacecraft separation at minimal cost and risk.

  3. Improvement in Generic Problem-Solving Abilities of Students by Use of Tutor-less Problem-Based Learning in a Large Classroom Setting

    PubMed Central

    Klegeris, Andis; Bahniwal, Manpreet; Hurren, Heather

    2013-01-01

    Problem-based learning (PBL) was originally introduced in medical education programs as a form of small-group learning, but its use has now spread to large undergraduate classrooms in various other disciplines. Introduction of new teaching techniques, including PBL-based methods, needs to be justified by demonstrating the benefits of such techniques over classical teaching styles. Previously, we demonstrated that introduction of tutor-less PBL in a large third-year biochemistry undergraduate class increased student satisfaction and attendance. The current study assessed the generic problem-solving abilities of students from the same class at the beginning and end of the term, and compared student scores with similar data obtained in three classes not using PBL. Two generic problem-solving tests of equal difficulty were administered such that students took different tests at the beginning and the end of the term. Blinded marking showed a statistically significant 13% increase in the test scores of the biochemistry students exposed to PBL, while no trend toward significant change in scores was observed in any of the control groups not using PBL. Our study is among the first to demonstrate that use of tutor-less PBL in a large classroom leads to statistically significant improvement in generic problem-solving skills of students. PMID:23463230

  4. [Cancer nursing care education programs: the effectiveness of different teaching methods].

    PubMed

    Cheng, Yun-Ju; Kao, Yu-Hsiu

    2012-10-01

    In-service education affects the quality of cancer care directly. Using classroom teaching to deliver in-service education is often ineffective due to participants' large workload and shift requirements. This study evaluated the learning effectiveness of different teaching methods in the dimensions of knowledge, attitude, and learning satisfaction. This study used a quasi-experimental study design. Participants were cancer ward nurses working at one medical center in northern Taiwan. Participants were divided into an experimental group and control group. The experimental group took an e-learning course and the control group took a standard classroom course using the same basic course material. Researchers evaluated the learning efficacy of each group using a questionnaire based on the quality of cancer nursing care learning effectiveness scale. All participants answered the questionnaire once before and once after completing the course. (1) Post-test "knowledge" scores for both groups were significantly higher than pre-test scores for both groups. Post-test "attitude" scores were significantly higher for the control group, while the experimental group reported no significant change. (2) after a covariance analysis of the pre-test scores for both groups, the post-test score for the experimental group was significantly lower than the control group in the knowledge dimension. Post-test scores did not differ significantly from pre-test scores for either group in the attitude dimension. (3) Post-test satisfaction scores between the two groups did not differ significantly with regard to teaching methods. The e-learning method, however, was demonstrated as more flexible than the classroom teaching method. Study results demonstrate the importance of employing a variety of teaching methods to instruct clinical nursing staff. We suggest that both classroom teaching and e-learning instruction methods be used to enhance the quality of cancer nursing care education programs. We also encourage that interactivity between student and instructor be incorporated into e-learning course designs to enhance effectiveness.

  5. Vestibular Assessments in Children With Global Developmental Delay: An Exploratory Study.

    PubMed

    Dannenbaum, Elizabeth; Horne, Victoria; Malik, Farwa; Villeneuve, Myriam; Salvo, Lora; Chilingaryan, Gevorg; Lamontagne, Anouk

    2016-01-01

    To compare results of 3 clinical vestibular tests between children with global developmental delay (GDD) and children with typical development (TD) and investigate the test-retest reliability. Twenty children with GDD (aged 4.1-12.1 years) and 11 age-matched controls with TD participated. Participants with GDD underwent 2 sessions of testing. Each session consisted of the Clinical Test of Sensory Interaction and Balance (CTSIB), Dynamic Visual Acuity (DVA) test, and the modified Emory Clinical Vestibular Chair Test (m-ECVCT). Up to 33% of the children with GDD had abnormal DVA scores. m-ECVCT results of children with GDD demonstrated larger variance than children with TD. The CTSIB score was significantly reduced in the group with GDD. The test-retest reliability varied, with good reliability for the m-ECVCT and CTSIB, and fair reliability for the DVA. Findings suggest vestibular involvement in children in GDD. The clinical tests demonstrated moderate test-retest reliability.

  6. Analytical Characterisation of Nanoscale Zero-Valent Iron: A Methodological Review

    EPA Science Inventory

    Zero-valent iron nanoparticles (nZVI) have been widely tested as they are showing significant promise for environmental remediation. However, many recent studies have demonstrated that their mobility and reactivity in subsurface environments are significantly affected by their te...

  7. Freight Wing Trailer Aerodynamics Final Technical Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sean Graham

    2007-10-31

    Freight Wing Incorporated utilized the opportunity presented by a DOE category two Inventions and Innovations grant to commercialize and improve upon aerodynamic technology for semi-tuck trailers, capable of decreasing heavy vehicle fuel consumption, related environmental damage, and U.S. consumption of foreign oil. Major project goals included the demonstration of aerodynamic trailer technology in trucking fleet operations, and the development and testing of second generation products. A great deal of past scientific research has demonstrated that streamlining box shaped semi-trailers can significantly reduce a truck’s fuel consumption. However, significant design challenges have prevented past concepts from meeting industry needs. Freight Wingmore » utilized a 2003 category one Inventions and Innovations grant to develop practical solutions to trailer aerodynamics. Fairings developed for the front, rear, and bottom of standard semi-trailers together demonstrated a 7% improvement to fuel economy in scientific tests conducted by the Transportation Research Center (TRC). Operational tests with major trucking fleets proved the functionality of the products, which were subsequently brought to market. This category two grant enabled Freight Wing to further develop, test and commercialize its products, resulting in greatly increased understanding and acceptance of aerodynamic trailer technology. Commercialization was stimulated by offering trucking fleets 50% cost sharing on trial implementations of Freight Wing products for testing and evaluation purposes. Over 230 fairings were implemented through the program with 35 trucking fleets including industry leaders such as Wal-Mart, Frito Lay and Whole Foods. The feedback from these testing partnerships was quite positive with product performance exceeding fleet expectations in many cases. Fleet feedback also was also valuable from a product development standpoint and assisted the design of several second generation products intended to further improve efficiency, lower costs, and enhance durability. Resulting products demonstrated a 30% efficiency improvement in full scale wind tunnel tests. The fuel savings of our most promising product, the “Belly Fairing” increased from 4% to 6% in scientific track and operational tests. The project successfully demonstrated the economic feasibility of trailer aerodynamics and positioned the technology to realize significant public benefits. Scientific testing conducted with partners such as the EPA Smartway program and Transport Canada clearly validated the fuel and emission saving potential of the technology. The Smartway program now recommends trailer aerodynamics as a certified fuel saving technology and is offering incentives such as low interest loans. Trailer aerodynamics can save average trucks over 1,100 gallons of fuel an 13 tons of emissions every 100,000 miles, a distance many trucks travel annually. These fuel savings produce a product return on investment period of one to two years in average fleet operations. The economic feasibility of the products was validated by participating fleets, several of which have since completed large implementations or demonstrated an interest in volume orders. The commercialization potential of the technology was also demonstrated, resulting in a national distribution and manufacturing partnership with a major industry supplier, Carrier Transicold. Consequently, Freight Wing is well positioned to continue marketing trailer aerodynamics to the trucking industry. The participation of leading fleets in this project served to break down the market skepticism that represents a primary barrier to widespread industry utilization. The benefits of widespread utilization of the technology could be quite significant for both the transportation industry and the public. Trailer aerodynamics could potentially save the U.S. trucking fleet over a billion gallons of fuel and 20 million tons of emissions annually.« less

  8. Investigating the effects of maximal anaerobic fatigue on dynamic postural control using the Y-Balance Test.

    PubMed

    Johnston, William; Dolan, Kara; Reid, Niamh; Coughlan, Garrett F; Caulfield, Brian

    2018-01-01

    The Y Balance Test is one of the most commonly used dynamic balance assessments, providing an insight into the integration of the sensorimotor subsystems. In recent times, there has been an increase in interest surrounding it's use in various clinical populations demonstrating alterations in motor function. Therefore, it is important to examine the effect physiological influences such as fatigue play in dynamic postural control, and establish a timeframe for its recovery. Descriptive laboratory study. Twenty male and female (age 23.75±4.79years, height 174.12±8.45cm, mass 69.32±8.76kg) partaking in competitive sport, completed the Y Balance Test protocol at 0, 10 and 20min, prior to a modified 60s Wingate fatiguing protocol. Post-fatigue assessments were then completed at 0, 10 and 20 min post-fatiguing intervention. Intraclass correlation coefficients demonstrated excellent intra-session reliability (0.976-0.982) across the three pre-fatigue YBT tests. Post-hoc paired sample t-tests demonstrated that all three reach directions demonstrated statistically significant differences between pre-fatigue and the first post-fatigue measurement (anterior; p=0.019, posteromedial; p=0.019 & posterolateral; p=0.003). The anterior reach direction returned to pre-fatigue levels within 10min (p=0.632). The posteromedial reach direction returned to pre-fatigue levels within 20min (p=0.236), while the posterolateral direction maintained a statistically significant difference at 20min (p=0.023). Maximal anaerobic fatigue has a negative effect on normalised Y balance test scores in all three directions. Following the fatiguing protocol, dynamic postural control returns to pre-fatigue levels for the anterior (<10min), posteromedial (<20min) and posterolateral (>20min). Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  9. JT90 thermal barrier coated vanes

    NASA Technical Reports Server (NTRS)

    Sheffler, K. D.; Graziani, R. A.; Sinko, G. C.

    1982-01-01

    The technology of plasma sprayed thermal barrier coatings applied to turbine vane platforms in modern high temperature commercial engines was advanced to the point of demonstrated feasibility for application to commercial aircraft engines. The three thermal barrier coatings refined under this program are zirconia stabilized with twenty-one percent magnesia (21% MSZ), six percent yttria (6% YSZ), and twenty percent yttria (20% YSZ). Improvement in thermal cyclic endurance by a factor of 40 times was demonstrated in rig tests. A cooling system evolved during the program which featured air impingement cooling for the vane platforms rather than film cooling. The impingement cooling system, in combination with the thermal barrier coatings, reduced platform cooling air requirements by 44% relative to the current film cooling system. Improved durability and reduced cooling air requirements were demonstrated in rig and engine endurance tests. Two engine tests were conducted, one of 1000 cycles and the other of 1500 cycles. All three coatings applied to vanes fabricated with the final cooling system configuration completed the final 1500 cycle engine endurance test. Results of this test clearly demonstrated the durability of the 6% YSZ coating which was in very good condition after the test. The 21% MSZ and 20% YSZ coatings had numerous occurrences of significant spalling in the test.

  10. The Oxytocin Receptor (OXTR) Contributes to Prosocial Fund Allocations in the Dictator Game and the Social Value Orientations Task

    PubMed Central

    Israel, Salomon; Lerer, Elad; Shalev, Idan; Uzefovsky, Florina; Riebold, Mathias; Laiba, Efrat; Bachner-Melman, Rachel; Maril, Anat; Bornstein, Gary; Knafo, Ariel; Ebstein, Richard P.

    2009-01-01

    Background Economic games observe social decision making in the laboratory that involves real money payoffs. Previously we have shown that allocation of funds in the Dictator Game (DG), a paradigm that illustrates costly altruistic behavior, is partially determined by promoter-region repeat region variants in the arginine vasopressin 1a receptor gene (AVPR1a). In the current investigation, the gene encoding the related oxytocin receptor (OXTR) was tested for association with the DG and a related paradigm, the Social Values Orientation (SVO) task. Methodology/Principal Findings Association (101 male and 102 female students) using a robust-family based test between 15 single tagging SNPs (htSNPs) across the OXTR was demonstrated with both the DG and SVO. Three htSNPs across the gene region showed significant association with both of the two games. The most significant association was observed with rs1042778 (p = 0.001). Haplotype analysis also showed significant associations for both DG and SVO. Following permutation test adjustment, significance was observed for 2–5 locus haplotypes (p<0.05). A second sample of 98 female subjects was subsequently and independently recruited to play the dictator game and was genotyped for the three significant SNPs found in the first sample. The rs1042778 SNP was shown to be significant for the second sample as well (p = 0.004, Fisher's exact test). Conclusions The demonstration that genetic polymorphisms for the OXTR are associated with human prosocial decision making converges with a large body of animal research showing that oxytocin is an important social hormone across vertebrates including Homo sapiens. Individual differences in prosocial behavior have been shown by twin studies to have a substantial genetic basis and the current investigation demonstrates that common variants in the oxytocin receptor gene, an important element of mammalian social circuitry, underlie such individual differences. PMID:19461999

  11. Impact of Breast Reader Assessment Strategy on mammographic radiologists' test reading performance.

    PubMed

    Suleiman, Wasfi I; Rawashdeh, Mohammad A; Lewis, Sarah J; McEntee, Mark F; Lee, Warwick; Tapia, Kriscia; Brennan, Patrick C

    2016-06-01

    The detection of breast cancer is somewhat limited by human factors, and thus there is a need to improve reader performance. This study assesses whether radiologists who regularly undertake the education in the form of the Breast Reader Assessment Strategy (BREAST) demonstrate any changes in mammography interpretation performance over time. In 2011, 2012 and 2013, 14 radiologists independently assessed a year-specific BREAST mammographic test-set. Radiologists read a different single test-set once each year, with each comprising 60 digital mammogram cases. Radiologists marked the location of suspected lesions without computer-aided diagnosis (CAD) and assigned a confidence rating of 2 for benign and 3-5 for malignant lesions. The mean sensitivity, specificity, location sensitivity, JAFROC FOM and ROC AUC were calculated. A Kruskal-Wallis test was used to compare the readings for the 14 radiologists across the 3 years. Wilcoxon signed rank test was used to assess comparison between pairs of years. Relationships between changes in performance and radiologist characteristics were examined using a Spearman's test. Significant increases were noted in mean sensitivity (P = 0.01), specificity (P = 0.01), location sensitivity (P = 0.001) and JAFROC FOM (P = 0.001) between 2011 and 2012. Between 2012 and 2013, significant improvements were noted in mean sensitivity (P = 0.003), specificity (P = 0.002), location sensitivity (P = 0.02), JAFROC FOM (P = 0.005) and ROC AUC (P = 0.008). No statistically significant correlations were shown between the levels of improvement and radiologists' characteristics. Radiologists' who undertake the BREAST programme demonstrate significant improvements in test-set performance during a 3-year period, highlighting the value of ongoing education through the use of test-set. © 2016 The Royal Australian and New Zealand College of Radiologists.

  12. The clinical evaluation of the CADence device in the acoustic detection of coronary artery disease.

    PubMed

    Thomas, Joseph L; Ridner, Michael; Cole, Jason H; Chambers, Jeffrey W; Bokhari, Sabahat; Yannopoulos, Demetris; Kern, Morton; Wilson, Robert F; Budoff, Matthew J

    2018-06-23

    The noninvasive detection of turbulent coronary flow may enable diagnosis of significant coronary artery disease (CAD) using novel sensor and analytic technology. Eligible patients (n = 1013) with chest pain and CAD risk factors undergoing nuclear stress testing were studied using the CADence (AUM Cardiovascular Inc., Northfield MN) acoustic detection (AD) system. The trial was designed to demonstrate non-inferiority of AD for diagnostic accuracy in detecting significant CAD as compared to an objective performance criteria (sensitivity 83% and specificity 80%, with 15% non-inferiority margins) for nuclear stress testing. AD analysis was blinded to clinical, core lab-adjudicated angiographic, and nuclear data. The presence of significant CAD was determined by computed tomographic (CCTA) or invasive angiography. A total of 1013 subjects without prior coronary revascularization or Q-wave myocardial infarction were enrolled. Primary analysis was performed on subjects with complete angiographic and AD data (n = 763) including 111 subjects (15%) with severe CAD based on CCTA (n = 34) and invasive angiography (n = 77). The sensitivity and specificity of AD were 78% (p = 0.012 for non-inferiority) and 35% (p < 0.001 for failure to demonstrate non-inferiority), respectively. AD results had a high 91% negative predictive value for the presence of significant CAD. AD testing failed to demonstrate non-inferior diagnostic accuracy as compared to the historical performance of a nuclear stress OPC due to low specificity. AD sensitivity was non-inferior in detecting significant CAD with a high negative predictive value supporting a potential value in excluding CAD.

  13. CECE: Expanding the Envelope of Deep Throttling Technology in Liquid Oxygen/Liquid Hydrogen Rocket Engines for NASA Exploration Missions

    NASA Technical Reports Server (NTRS)

    Giuliano, Victor J.; Leonard, Timothy G.; Lyda, Randy T.; Kim, Tony S.

    2010-01-01

    As one of the first technology development programs awarded by NASA under the Vision for Space Exploration, the Pratt & Whitney Rocketdyne (PWR) Deep Throttling, Common Extensible Cryogenic Engine (CECE) program was selected by NASA in November 2004 to begin technology development and demonstration toward a deep throttling, cryogenic engine supporting ongoing trade studies for NASA s Lunar Lander descent stage. The CECE program leverages the maturity and previous investment of a flight-proven hydrogen/oxygen expander cycle engine, the PWR RL10, to develop and demonstrate an unprecedented combination of reliability, safety, durability, throttlability, and restart capabilities in high-energy, cryogenic, in-space propulsion. The testbed selected for the deep throttling demonstration phases of this program was a minimally modified RL10 engine, allowing for maximum current production engine commonality and extensibility with minimum program cost. Four series of demonstrator engine tests have been successfully completed between April 2006 and April 2010, accumulating 7,436 seconds of hot fire time over 47 separate tests. While the first two test series explored low power combustion (chug) and system instabilities, the third test series investigated and was ultimately successful in demonstrating several mitigating technologies for these instabilities and achieved a stable throttling ratio of 13:1. The fourth test series significantly expanded the engine s operability envelope by successfully demonstrating a closed-loop control system and extensive transient modeling to enable lower power engine starting, faster throttle ramp rates, and mission-specific ignition testing. The final hot fire test demonstrated a chug-free, minimum power level of 5.9%, corresponding to an overall 17.6:1 throttling ratio achieved. In total, these tests have provided an early technology demonstration of an enabling cryogenic propulsion concept with invaluable system-level technology data acquisition toward design and development risk mitigation for future lander descent main engines.

  14. The Activity of Antimicrobial Surfaces Varies by Testing Protocol Utilized

    PubMed Central

    Campos, Matias D.; Zucchi, Paola C.; Phung, Ann; Leonard, Steven N.; Hirsch, Elizabeth B.

    2016-01-01

    Background Contaminated hospital surfaces are an important source of nosocomial infections. A major obstacle in marketing antimicrobial surfaces is a lack of efficacy data based on standardized testing protocols. Aim We compared the efficacy of multiple testing protocols against several “antimicrobial” film surfaces. Methods Four clinical isolates were used: one Escherichia coli, one Klebsiella pneumoniae, and two Staphylococcus aureus strains. Two industry methods (modified ISO 22196 and ASTM E2149), a “dried droplet”, and a “transfer” method were tested against two commercially available antimicrobial films, one film in development, an untreated control, and a positive (silver) control film. At 2 (only ISO) and 24 hours following inoculation, bacteria were collected from film surfaces and enumerated. Results Compared to untreated films in all protocols, there were no significant differences in recovery on either commercial brand at 2 or 24 hours after inoculation. The silver surface demonstrated significant microbicidal activity (mean loss 4.9 Log10 CFU/ml) in all methods and time points with the exception of 2 hours in the ISO protocol and the transfer method. Using our novel droplet method, no differences between placebo and active surfaces were detected. The surface in development demonstrated variable activity depending on method, organism, and time point. The ISO demonstrated minimal activity at 2 hours but significant activity at 24 hours (mean 4.5 Log10 CFU/ml difference versus placebo). The ASTEM protocol exhibited significant differences in recovery of staphylococci (mean 5 Log10 CFU/ml) but not Gram-negative isolates (10 fold decrease). Minimal activity was observed with this film in the transfer method. Conclusions Varying results between protocols suggested that efficacy of antimicrobial surfaces cannot be easily and reproducibly compared. Clinical use should be considered and further development of representative methods is needed. PMID:27494336

  15. Stirling Space Engine Program. Volume 1; Final Report

    NASA Technical Reports Server (NTRS)

    Dhar, Manmohan

    1999-01-01

    The objective of this program was to develop the technology necessary for operating Stirling power converters in a space environment and to demonstrate this technology in full-scale engine tests. Hardware development focused on the Component Test Power Converter (CTPC), a single cylinder, 12.5-kWe engine. Design parameters for the CTPC were 150 bar operating pressure, 70 Hz frequency, and hot-and cold-end temperatures of 1050 K and 525 K, respectively. The CTPC was also designed for integration with an annular sodium heat pipe at the hot end, which incorporated a unique "Starfish" heater head that eliminated highly stressed brazed or weld joints exposed to liquid metal and used a shaped-tubed electrochemical milling process to achieve precise positional tolerances. Selection of materials that could withstand high operating temperatures with long life were another focus. Significant progress was made in the heater head (Udimet 700 and Inconel 718 and a sodium-filled heat pipe); the alternator (polyimide-coated wire with polyimide adhesive between turns and a polyimide-impregnated fiberglass overwrap and samarium cobalt magnets); and the hydrostatic gas bearings (carbon graphite and aluminum oxide for wear couple surfaces). Tests on the CTPC were performed in three phases: cold end testing (525 K), engine testing with slot radiant heaters, and integrated heat pipe engine system testing. Each test phase was successful, with the integrated engine system demonstrating a power level of 12.5 kWe and an overall efficiency of 22 percent in its maiden test. A 1500-hour endurance test was then successfully completed. These results indicate the significant achievements made by this program that demonstrate the viability of Stirling engine technology for space applications.

  16. Reduced Clostridium difficile Tests and Laboratory-Identified Events With a Computerized Clinical Decision Support Tool and Financial Incentive.

    PubMed

    Madden, Gregory R; German Mesner, Ian; Cox, Heather L; Mathers, Amy J; Lyman, Jason A; Sifri, Costi D; Enfield, Kyle B

    2018-06-01

    We hypothesized that a computerized clinical decision support tool for Clostridium difficile testing would reduce unnecessary inpatient tests, resulting in fewer laboratory-identified events. Census-adjusted interrupted time-series analyses demonstrated significant reductions of 41% fewer tests and 31% fewer hospital-onset C. difficile infection laboratory-identified events following this intervention.Infect Control Hosp Epidemiol 2018;39:737-740.

  17. The role of chronotype, gender, test anxiety, and conscientiousness in academic achievement of high school students.

    PubMed

    Rahafar, Arash; Maghsudloo, Mahdis; Farhangnia, Sajedeh; Vollmer, Christian; Randler, Christoph

    2016-01-01

    Previous findings have demonstrated that chronotype (morningness/intermediate/eveningness) is correlated with cognitive functions, that is, people show higher mental performance when they do a test at their preferred time of day. Empirical studies found a relationship between morningness and higher learning achievement at school and university. However, only a few of them controlled for other moderating and mediating variables. In this study, we included chronotype, gender, conscientiousness and test anxiety in a structural equation model (SEM) with grade point average (GPA) as academic achievement outcome. Participants were 158 high school students and results revealed that boys and girls differed in GPA and test anxiety significantly, with girls reporting better grades and higher test anxiety. Moreover, there was a positive correlation between conscientiousness and GPA (r = 0.17) and morningness (r = 0.29), respectively, and a negative correlation between conscientiousness and test anxiety (r = -0.22). The SEM demonstrated that gender was the strongest predictor of academic achievement. Lower test anxiety predicted higher GPA in girls but not in boys. Additionally, chronotype as moderator revealed a significant association between gender and GPA for evening types and intermediate types, while intermediate types showed a significant relationship between test anxiety and GPA. Our results suggest that gender is an essential predictor of academic achievement even stronger than low or absent test anxiety. Future studies are needed to explore how gender and chronotype act together in a longitudinal panel design and how chronotype is mediated by conscientiousness in the prediction of academic achievement.

  18. Color stability of esthetic restorative materials: a spectrophotometric analysis.

    PubMed

    Poggio, Claudio; Ceci, Matteo; Beltrami, Riccardo; Mirando, Maria; Wassim, Jaffal; Colombo, Marco

    2016-12-01

    Objective: The aim of this in vitro study was to evaluate the color stability of different restorative materials (one microfilled composite, one nanofilled composite, one nanohybrid composite and one Ormocer-based composite) after exposure to different staining solutions (coffee, coca-cola and red wine). Material and methods: All materials were polymerized into silicon rings (2 mm ×6 mm ×8 mm) to obtain specimens identical in size. Thirty cylindrical specimens of each material were prepared. They were immersed in staining solutions over a 28-day test period. A colorimetric evaluation according to the CIE L*a*b* system was performed by a blind trained operator at 7, 14, 21, 28 days of the staining process. The Shapiro-Wilk test and Kruskal-Wallis ANOVA were applied to assess significant differences among restorative materials. The paired t -test was applied to test which CIE L*a*b* parameters significantly changed after immersion in staining solutions. Results: All restorative materials showed clinically perceptible color differences after immersion in coffee. L* and b* values showed the highest variability. Coca cola and red wine did not influence the color stability for all restorative materials except for Filtek Supreme XTE. Conclusions: Coffee caused a significant color change in all types of tested composite resins. Filtek Supreme XTE demonstrated alone a staining susceptibility to red wine; no other significant differences among the materials were demonstrated. Long-term exposure to some food dyes (coffee in particular) can significantly affect the color stability of modern esthetic restorative materials regardless of materials' different composition.

  19. [Neuropsychological modifications at high altitude: from Pamir to Karakorum].

    PubMed

    Nardi, Bernardo; Brandoni, Marco; Capecci, Ilaria; Castellani, Simona; Rupoli, Sara; Bellantuono, Cesario

    2009-01-01

    Neuropsychological modifications and acclimatization processes at over 8000 without auxiliary oxygen were investigated in two climbers, evaluating attentive abilities and matching their performances. During rest in base-camp (4800 m), at other three Resorts - Resort I (5800 m), Resort II (6400 m), Resort III (7200 m) -, and four months after the return at low altitude, were administered: Temporal Orientation Test (TOT), Trail Making Test (TMT), Animal Naming (AN), Verbal Fluency Test (VFT), Arithmetical Judgment Test (AJT), and Drawing Test (DT). Results. At TOT and at AJT, both the climbers demonstrated scores at higher normal levels (Eq = 4) in all the Resorts in which they were performed. They showed an impairment at AN test, especially at Resort III, showing sensitivity of animal naming to hypoxia. At the DT, human figures were reduced in their dimensions and details, as consequence of the tendency to self closure and introversion that occurs at higher altitudes. Neuropsychological functions concerning verbal fluency showed sensitivity to hypoxia, especially at higher altitudes. TMT demonstrated that attentive ability can be preserved if acclimatization is good. Sensitivity to hypoxia and acclimatization processes showed a significant subjective variability. The results of this study show that exposure to high altitude produces some significant neuropsychological changes.

  20. Historical background and design evolution of the transonic aircraft technology supercritical wing

    NASA Technical Reports Server (NTRS)

    Ayers, T. G.; Hallissy, J. B.

    1981-01-01

    Two dimensional wind tunnel test results obtained for supercritical airfoils indicated that substantial improvements in aircraft performance at high subsonic speeds could be achieved by shaping the airfoil to improve the supercritical flow above the upper surface. Significant increases in the drag divergence Mach number, the maximum lift coefficient for buffer onset, and the Mach number for buffet onset at a given lift coefficient were demonstrated for the supercritical airfoil, as compared with a NACA 6 series airfoil of comparable thickness. These trends were corroborated by results from three dimensional wind tunnel and flight tests. Because these indicated extensions of the buffet boundaries could provide significant improvements in the maneuverability of a fighter airplane, an exploratory wind tunnel investigation was initiated which demonstrated that significant aerodynamic improvements could be achieved from the direct substitution of a supercritical airfoil on a variable wing sweep multimission airplane model.

  1. Reliability and validity of Short Form 36 Version 2 to measure health perceptions in a sub-group of individuals with fatigue.

    PubMed

    Davenport, Todd E; Stevens, Staci R; Baroni, Katie; Van Ness, J Mark; Snell, Christopher R

    2011-01-01

    To determine the validity and reliability of Short Form 36 Version 2 (SF36v2) in sub-groups of individuals with fatigue. Thirty subjects participated in this study, including n = 16 subjects who met case definition criteria for chronic fatigue syndrome (CFS) and n = 14 non-disabled sedentary matched control subjects. SF36v2 and Multidimensional Fatigue Inventory (MFI-20) were administered before two maximal cardiopulmonary exercise tests (CPETs) administered 24 h apart and an open-ended recovery questionnaire was administered 7 days after CPET challenge. The main outcome measures were self-reported time to recover to pre-challenge functional and symptom status, frequency of post-exertional symptoms and SF36v2 sub-scale scores. Individuals with CFS demonstrated significantly lower SF36v2 and MFI-20 sub-scale scores prior to CPET. Between-group differences remained significant post-CPET, however, there were no significant group by test interaction effects. Subjects with CFS reported significantly more total symptoms (p < 0.001), as well as reports of fatigue (p < 0.001), neuroendocrine (p < 0.001), immune (p < 0.01), pain (p < 0.01) and sleep disturbance (p < 0.01) symptoms than control subjects as a result of CPET. Many symptom counts demonstrated significant relationships with SF36v2 sub-scale scores (p < 0.05). SF36v2 and MFI-20 sub-scale scores demonstrated significant correlations (p < 0.05). Various SF36v2 sub-scale scores demonstrated significant predictive validity to identify subjects who recovered from CPET challenge within 1 day and 7 days (p < 0.05). Potential floor effects were observed for both questionnaires for individuals with CFS. Various sub-scales of SF36v2 demonstrated adequate reliability and validity for clinical and research applications. Adequacy of sensitivity to change of SF36v2 as a result of a fatiguing stressor should be the subject of additional study.

  2. Effect of rhBMP-2 on tibial plateau fractures in a canine model.

    PubMed

    Schaefer, Susan L; Lu, Yan; Seeherman, Howard; Li, X Jian; Lopez, Mandi J; Markel, Mark D

    2009-04-01

    This study was to determine the efficacy of recombinant human bone morphogenetic protien-2 (rhBMP-2)/calcium phosphate matrix (CPX) paste to accelerate healing in a canine articular fracture model with associated subchondral defect. rhBMP-2/CPX (BMP), CPX alone (CPX) or autogenous bone graft (ABG) was administered to a canine articular tibial plateau osteotomy with a subchondral defect in each of 21 female dogs. The unoperated contralateral limbs served as controls. Ground reaction forces, synovial fluid, radiographic changes, mechanical testing, bone density, and histology of bone and synovium were analyzed at 6 weeks after surgery. Radiographic analysis demonstrated that the BMP and CPX groups showed improved bony healing compared to the ABG group at week 6. Histomorphometric analysis demonstrated that the BMP group had significantly increased trabecular bone volume compared to the CPX and ABG groups. Mechanical testing revealed that the BMP group had significantly greater maximum failure loads than the ABG group. Histological analysis demonstrated that the BMP group had significantly less sub-synovial inflammation than CPX group. This study demonstrated that rhBMP-2/CPX accelerated healing of articular fractures with subchondral defect compared to ABG in most of the parameters evaluated, and had less subsynovial inflammation than the CPX alone in a canine model.

  3. Route Learning Impairment in Temporal Lobe Epilepsy

    PubMed Central

    Bell, Brian D.

    2012-01-01

    Memory impairment on neuropsychological tests is relatively common in temporal lobe epilepsy (TLE) patients. But memory rarely has been evaluated in more naturalistic settings. This study assessed TLE (n = 19) and control (n = 32) groups on a real-world route learning (RL) test. Compared to the controls, the TLE group committed significantly more total errors across the three RL test trials. RL errors correlated significantly with standardized auditory and visual memory and visual-perceptual test scores in the TLE group. In the TLE subset for whom hippocampal data were available (n = 14), RL errors also correlated significantly with left hippocampal volume. This is one of the first studies to demonstrate real-world memory impairment in TLE patients and its association with both mesial temporal lobe integrity and standardized memory test performance. The results support the ecological validity of clinical neuropsychological assessment. PMID:23041173

  4. Three-body wear of resin denture teeth with and without nanofillers.

    PubMed

    Stober, Thomas; Henninger, Moritz; Schmitter, Marc; Pritsch, Maria; Rammelsberg, Peter

    2010-02-01

    The wear behavior of newly developed denture teeth with nanofillers may be different from teeth with other chemical formulations. The purpose of this study was to examine the 3-body wear resistance of 11 different commercially available resin denture teeth. The materials tested were conventional (SR Orthotyp PE, Orthognath) and cross-linked acrylic resin teeth without inorganic fillers (Premium 8, SR Postaris DCL, Trubyte Portrait, Artiplus), composite resin teeth with inorganic fillers (SR Orthosit PE, Vitapan), and composite resin teeth (experimental materials) with inorganic nanofillers (NC Veracia Posterior, e-Ha, Mondial). Human enamel and a ceramic denture tooth (Lumin Vacuum) were used as reference materials. The 3-body wear test was performed in a wear machine developed by the Academic Center for Dentistry Amsterdam (ACTA), with millet suspension acting as an abrasive medium (n=10, test load: 15 N, slip rate: 20%, number of cycles: 100,000). Wear was determined with the aid of a profilometer. Data were analyzed with the Kruskal-Wallis test and Mann-Whitney U test using the closed testing approach (significance level for familywise error rate, alpha=.05). None of the acrylic and composite resin materials tested in this study demonstrated the 3-body wear resistance of ceramic teeth or human enamel. Teeth with inorganic fillers demonstrated significantly lower wear values than conventional or cross-linked acrylic resin teeth without fillers. Composite resin teeth with traditional fillers showed significantly lower wear than composite resin teeth with nanofillers. Denture teeth with and without inorganic fillers differed significantly with regard to the degree of wear generated in the ACTA wear simulator. The incorporation of nanofillers did not improve the wear resistance compared to teeth with traditional fillers.

  5. Increasing the statistical significance of entanglement detection in experiments.

    PubMed

    Jungnitsch, Bastian; Niekamp, Sönke; Kleinmann, Matthias; Gühne, Otfried; Lu, He; Gao, Wei-Bo; Chen, Yu-Ao; Chen, Zeng-Bing; Pan, Jian-Wei

    2010-05-28

    Entanglement is often verified by a violation of an inequality like a Bell inequality or an entanglement witness. Considerable effort has been devoted to the optimization of such inequalities in order to obtain a high violation. We demonstrate theoretically and experimentally that such an optimization does not necessarily lead to a better entanglement test, if the statistical error is taken into account. Theoretically, we show for different error models that reducing the violation of an inequality can improve the significance. Experimentally, we observe this phenomenon in a four-photon experiment, testing the Mermin and Ardehali inequality for different levels of noise. Furthermore, we provide a way to develop entanglement tests with high statistical significance.

  6. Field Test Results of Using a Nacelle-Mounted Lidar for Improving Wind Energy Capture by Reducing Yaw Misalignment (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fleming, P.; Scholbrock, A.; Wright, A.

    2014-11-01

    Presented at the Nordic Wind Power Conference on November 5, 2014. This presentation describes field-test campaigns performed at the National Wind Technology Center in which lidar technology was used to improve the yaw alignment of the Controls Advanced Research Turbine (CART) 2 and CART3 wind turbines. The campaigns demonstrated that whether by learning a correction function to the nacelle vane, or by controlling yaw directly with the lidar signal, a significant improvement in power capture was demonstrated.

  7. Immersive Theater - a Proven Way to Enhance Learning Retention

    NASA Astrophysics Data System (ADS)

    Reiff, P. H.; Zimmerman, L.; Spillane, S.; Sumners, C.

    2014-12-01

    The portable immersive theater has gone from our first demonstration at fall AGU 2003 to a product offered by multiple companies in various versions to literally millions of users per year. As part of our NASA funded outreach program, we conducted a test of learning in a portable Discovery Dome as contrasted with learning the same materials (visuals and sound track) on a computer screen. We tested 200 middle school students (primarily underserved minorities). Paired t-tests and an independent t-test were used to compare the amount of learning that students achieved. Interest questionnaires were administered to participants in formal (public school) settings and focus groups were conducted in informal (museum camp and educational festival) settings. Overall results from the informal and formal educational setting indicated that there was a statistically significant increase in test scores after viewing We Choose Space. There was a statistically significant increase in test scores for students who viewed We Choose Space in the portable Discovery Dome (9.75) as well as with the computer (8.88). However, long-term retention of the material tested on the questionnaire indicated that for students who watched We Choose Space in the portable Discovery Dome, there was a statistically significant long-term increase in test scores (10.47), whereas, six weeks after learning on the computer, the improvements over the initial baseline (3.49) were far less and were not statistically significant. The test score improvement six weeks after learning in the dome was essentially the same as the post test immediately after watching the show, demonstrating virtually no loss of gained information in the six week interval. In the formal educational setting, approximately 34% of the respondents indicated that they wanted to learn more about becoming a scientist, while 35% expressed an interest in a career in space science. In the informal setting, 26% indicated that they were interested in pursuing a career in space science.

  8. DARPA/USAF/USN J-UCAS X-45A System Demonstration Program: A Review of Flight Test Site Processes and Personnel

    NASA Technical Reports Server (NTRS)

    Cosentino, Gary B.

    2008-01-01

    The Joint Unmanned Combat Air Systems (J-UCAS) program is a collaborative effort between the Defense Advanced Research Project Agency (DARPA), the US Air Force (USAF) and the US Navy (USN). Together they have reviewed X-45A flight test site processes and personnel as part of a system demonstration program for the UCAV-ATD Flight Test Program. The goal was to provide a disciplined controlled process for system integration and testing and demonstration flight tests. NASA's Dryden Flight Research Center (DFRC) acted as the project manager during this effort and was tasked with the responsibilities of range and ground safety, the provision of flight test support and infrastructure and the monitoring of technical and engineering tasks. DFRC also contributed their engineering knowledge through their contributions in the areas of autonomous ground taxi control development, structural dynamics testing and analysis and the provision of other flight test support including telemetry data, tracking radars, and communications and control support equipment. The Air Force Flight Test Center acted at the Deputy Project Manager in this effort and was responsible for the provision of system safety support and airfield management and air traffic control services, among other supporting roles. The T-33 served as a J-UCAS surrogate aircraft and demonstrated flight characteristics similar to that of the the X-45A. The surrogate served as a significant risk reduction resource providing mission planning verification, range safety mission assessment and team training, among other contributions.

  9. Does sensitivity measured from screening test-sets predict clinical performance?

    NASA Astrophysics Data System (ADS)

    Soh, BaoLin P.; Lee, Warwick B.; Mello-Thoms, Claudia R.; Tapia, Kriscia A.; Ryan, John; Hung, Wai Tak; Thompson, Graham J.; Heard, Rob; Brennan, Patrick C.

    2014-03-01

    Aim: To examine the relationship between sensitivity measured from the BREAST test-set and clinical performance. Background: Although the UK and Australia national breast screening programs have regarded PERFORMS and BREAST test-set strategies as possible methods of estimating readers' clinical efficacy, the relationship between test-set and real life performance results has never been satisfactorily understood. Methods: Forty-one radiologists from BreastScreen New South Wales participated in this study. Each reader interpreted a BREAST test-set which comprised sixty de-identified mammographic examinations sourced from the BreastScreen Digital Imaging Library. Spearman's rank correlation coefficient was used to compare the sensitivity measured from the BREAST test-set with screen readers' clinical audit data. Results: Results shown statistically significant positive moderate correlations between test-set sensitivity and each of the following metrics: rate of invasive cancer per 10 000 reads (r=0.495; p < 0.01); rate of small invasive cancer per 10 000 reads (r=0.546; p < 0.001); detection rate of all invasive cancers and DCIS per 10 000 reads (r=0.444; p < 0.01). Conclusion: Comparison between sensitivity measured from the BREAST test-set and real life detection rate demonstrated statistically significant positive moderate correlations which validated that such test-set strategies can reflect readers' clinical performance and be used as a quality assurance tool. The strength of correlation demonstrated in this study was higher than previously found by others.

  10. NREL to Lead Novel Field Demonstration of Wind Turbine Control at the Wind

    Science.gov Websites

    Power Plant Level | News | NREL to Lead Novel Field Demonstration of Wind Turbine Control at the Wind Power Plant Level NREL to Lead Novel Field Demonstration of Wind Turbine Control at the Wind to test wind turbine technology controls at the overall wind power plant level. This is a significant

  11. Multi-Physics Demonstration Problem with the SHARP Reactor Simulation Toolkit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merzari, E.; Shemon, E. R.; Yu, Y. Q.

    This report describes to employ SHARP to perform a first-of-a-kind analysis of the core radial expansion phenomenon in an SFR. This effort required significant advances in the framework Multi-Physics Demonstration Problem with the SHARP Reactor Simulation Toolkit used to drive the coupled simulations, manipulate the mesh in response to the deformation of the geometry, and generate the necessary modified mesh files. Furthermore, the model geometry is fairly complex, and consistent mesh generation for the three physics modules required significant effort. Fully-integrated simulations of a 7-assembly mini-core test problem have been performed, and the results are presented here. Physics models ofmore » a full-core model of the Advanced Burner Test Reactor have also been developed for each of the three physics modules. Standalone results of each of the three physics modules for the ABTR are presented here, which provides a demonstration of the feasibility of the fully-integrated simulation.« less

  12. The impact of service-learning on cultural competence.

    PubMed

    Amerson, Roxanne

    2010-01-01

    Service-learning provides an excellent pedagogy for introducing students to clients of different cultural backgrounds, helping students become aware of the issues these clients face related to culture and health care, and teaching culturally appropriate care. The Transcultural Self-Efficacy Tool was used to evaluate self-perceived cultural competence in a convenience sample of 60 baccalaureate nursing students enrolled in a community health nursing course following the completion of service-learning projects with local and international communities. Pre- and posttests were analyzed based on total scores and subscale (cognitive, practical, and affective) scores. A paired-samples t test compared the mean pretest total score to the mean posttest total score, which demonstrated a significant increase. In addition, paired-samples t tests demonstrated a significant increase in each subscale.

  13. Repeated Sprint Ability with Inclusion of Changing Direction among Veteran Soccer Players

    NASA Astrophysics Data System (ADS)

    Salleh, Omar Md; Nadzalan, Ali Md; Ikhwan Mohamad, Nur; Rahmat, Azali; Azny Mustafa, Mirza; Tan, Kevin

    2018-05-01

    This study was conducted to determine the repeated sprint ability (RSA) with the inclusion of changing direction among veteran soccer players. Twelve main players from a university veteran soccer team were recruited and were required to perform the RSA test in two conditions; i) without ball and ii) with ball. Descriptive statistics and Wilcoxon signed rank test was conducted to determine the mean score and the differences of sprint time, percentage of decrement score of sprinting (Sdec) and fatigue index (FI) between the two conditions. Both conditions demonstrated significantly drop in speed in the fifth sprint. Results showed sprint time, Sdec and FI were found to be significantly different between both conditions. Findings of this study demonstrated the important for specific training to sports for performance enhancement.

  14. Are Gender Differences in Perceived and Demonstrated Technology Literacy Significant? It Depends on the Model

    ERIC Educational Resources Information Center

    Hohlfeld, Tina N.; Ritzhaupt, Albert D.; Barron, Ann E.

    2013-01-01

    This paper examines gender differences related to Information and Communication Technology (ICT) literacy using two valid and internally consistent measures with eighth grade students (N = 1,513) from Florida public schools. The results of t test statistical analyses, which examined only gender differences in demonstrated and perceived ICT skills,…

  15. Reusable Solid Rocket Motor Nozzle Joint 5 Redesign

    NASA Technical Reports Server (NTRS)

    Lui, R. C.; Stratton, T. C.; LaMont, D. T.

    2003-01-01

    Torque tension testing of a newly designed Reusable Solid Rocket Motor nozzle bolted assembly was successfully completed. Test results showed that the 3-sigma preload variation was as expected at the required input torque level and the preload relaxation were within the engineering limits. A shim installation technique was demonstrated as a simple process to fill a shear lip gap between nozzle housings in the joint region. A new automated torque system was successfully demonstrated in this test. This torque control tool was found to be very precise and accurate. The bolted assembly performance was further evaluated using the Nozzle Structural Test Bed. Both current socket head cap screw and proposed multiphase alloy bolt configurations were tested. Results indicated that joint skip and bolt bending were significantly reduced with the new multiphase alloy bolt design. This paper summarizes all the test results completed to date.

  16. Testing the Effectiveness of Interactive Multimedia for Library-User Education

    ERIC Educational Resources Information Center

    Markey, Karen; Armstrong, Annie; De Groote, Sandy; Fosmire, Michael; Fuderer, Laura; Garrett, Kelly; Georgas, Helen; Sharp, Linda; Smith, Cheri; Spaly, Michael; Warner, Joni E.

    2005-01-01

    A test of the effectiveness of interactive multimedia Web sites demonstrates that library users' topic knowledge was significantly greater after visiting the sites than before. Library users want more such sites about library services, their majors, and campus life generally. Librarians describe the roles they want to play on multimedia production…

  17. Antinociceptive and Antioxidant Activities of Phytol In Vivo and In Vitro Models

    PubMed Central

    Santos, Camila Carolina de Menezes Patrício; Salvadori, Mirian Stiebbe; Mota, Vanine Gomes; Costa, Luciana Muratori; de Almeida, Antonia Amanda Cardoso; de Oliveira, Guilherme Antônio Lopes; Costa, Jéssica Pereira; de Freitas, Rivelilson Mendes; de Almeida, Reinaldo Nóbrega

    2013-01-01

    The objective of the present study was to evaluate the antinociceptive effects of phytol using chemical and thermal models of nociception in mice and to assess its antioxidant effects in vitro. Phytol was administered intraperitoneally (i.p.) to mice at doses of 25, 50, 100, and 200 mg/kg. In the acetic acid-induced writhing test, phytol significantly reduced the number of contortions compared to the control group (P < 0.001). In the formalin test, phytol reduced significantly the amount of time spent in paw licking in both phases (the neurogenic and inflammatory phases), this effect being more pronounced in the second phase (P < 0.001). Phytol also provoked a significant increase in latency in the hot plate test. These antinociceptive effects did not impaire the motor performance, as shown in the rotarod test. Phytol demonstrated a strong antioxidant effect in vitro in its capacity to remove hydroxyl radicals and nitric oxide as well as to prevent the formation of thiobarbituric acid reactive substances (TBARS). Taken as a whole, these results show the pronounced antinociceptive effects of phytol in the nociception models used, both through its central and peripheral actions, but also its antioxidant properties demonstrated in the in vitro methods used. PMID:26317107

  18. Biofeedback-assisted relaxation training to decrease test anxiety in nursing students.

    PubMed

    Prato, Catherine A; Yucha, Carolyn B

    2013-01-01

    Nursing students experiencing debilitating test anxiety may be unable to demonstrate their knowledge and have potential for poor academic performance. A biofeedback-assisted relaxation training program was created to reduce test anxiety. Anxiety was measured using Spielberger's Test Anxiety Inventory and monitoring peripheral skin temperature, pulse, and respiration rates during the training. Participants were introduced to diaphragmatic breathing, progressive muscle relaxation, and autogenic training. Statistically significant changes occurred in respiratory rates and skin temperatures during the diaphragmatic breathing session; respiratory rates and peripheral skin temperatures during progressive muscle relaxation session; respiratory and pulse rates, and peripheral skin temperatures during the autogenic sessions. No statistically significant difference was noted between the first and second TAI. Subjective test anxiety scores of the students did not decrease by the end of training. Autogenic training session was most effective in showing a statistically significant change in decreased respiratory and pulse rates and increased peripheral skin temperature.

  19. Cognitive Complaints After Breast Cancer Treatments: Examining the Relationship With Neuropsychological Test Performance

    PubMed Central

    2013-01-01

    Background Cognitive complaints are reported frequently after breast cancer treatments. Their association with neuropsychological (NP) test performance is not well-established. Methods Early-stage, posttreatment breast cancer patients were enrolled in a prospective, longitudinal, cohort study prior to starting endocrine therapy. Evaluation included an NP test battery and self-report questionnaires assessing symptoms, including cognitive complaints. Multivariable regression models assessed associations among cognitive complaints, mood, treatment exposures, and NP test performance. Results One hundred eighty-nine breast cancer patients, aged 21–65 years, completed the evaluation; 23.3% endorsed higher memory complaints and 19.0% reported higher executive function complaints (>1 SD above the mean for healthy control sample). Regression modeling demonstrated a statistically significant association of higher memory complaints with combined chemotherapy and radiation treatments (P = .01), poorer NP verbal memory performance (P = .02), and higher depressive symptoms (P < .001), controlling for age and IQ. For executive functioning complaints, multivariable modeling controlling for age, IQ, and other confounds demonstrated statistically significant associations with better NP visual memory performance (P = .03) and higher depressive symptoms (P < .001), whereas combined chemotherapy and radiation treatment (P = .05) approached statistical significance. Conclusions About one in five post–adjuvant treatment breast cancer patients had elevated memory and/or executive function complaints that were statistically significantly associated with domain-specific NP test performances and depressive symptoms; combined chemotherapy and radiation treatment was also statistically significantly associated with memory complaints. These results and other emerging studies suggest that subjective cognitive complaints in part reflect objective NP performance, although their etiology and biology appear to be multifactorial, motivating further transdisciplinary research. PMID:23606729

  20. How do video-based demonstration assessment tasks affect problem-solving process, test anxiety, chemistry anxiety and achievement in general chemistry students?

    NASA Astrophysics Data System (ADS)

    Terrell, Rosalind Stephanie

    2001-12-01

    Because paper-and-pencil testing provides limited knowledge about what students know about chemical phenomena, we have developed video-based demonstrations to broaden measurement of student learning. For example, students might be shown a video demonstrating equilibrium shifts. Two methods for viewing equilibrium shifts are changing the concentration of the reactants and changing the temperature of the system. The students are required to combine the data collected from the video and their knowledge of chemistry to determine which way the equilibrium shifts. Video-based demonstrations are important techniques for measuring student learning because they require students to apply conceptual knowledge learned in class to a specific chemical problem. This study explores how video-based demonstration assessment tasks affect problem-solving processes, test anxiety, chemistry anxiety and achievement in general chemistry students. Several instruments were used to determine students' knowledge about chemistry, students' test and chemistry anxiety before and after treatment. Think-aloud interviews were conducted to determine students' problem-solving processes after treatment. The treatment group was compared to a control group and a group watching video demonstrations. After treatment students' anxiety increased and achievement decreased. There were also no significant differences found in students' problem-solving processes following treatment. These negative findings may be attributed to several factors that will be explored in this study.

  1. Association between physiological falls risk and physical performance tests among community-dwelling older adults.

    PubMed

    Singh, Devinder K A; Pillai, Sharmila G K; Tan, Sin Thien; Tai, Chu Chiau; Shahar, Suzana

    2015-01-01

    Physical performance and balance declines with aging and may lead to increased risk of falls. Physical performance tests may be useful for initial fall-risk screening test among community-dwelling older adults. Physiological profile assessment (PPA), a composite falls risk assessment tool is reported to have 75% accuracy to screen for physiological falls risk. PPA correlates with Timed Up and Go (TUG) test. However, the association between many other commonly used physical performance tests and PPA is not known. The aim of the present study was to examine the association between physiological falls risk measured using PPA and a battery of physical performance tests. One hundred and forty older adults from a senior citizens club in Kuala Lumpur, Malaysia (94 females, 46 males), aged 60 years and above (65.77±4.61), participated in this cross-sectional study. Participants were screened for falls risk using PPA. A battery of physical performance tests that include ten-step test (TST), short physical performance battery (SPPB), functional reach test (FRT), static balance test (SBT), TUG, dominant hand-grip strength (DHGS), and gait speed test (GST) were also performed. Spearman's rank correlation and binomial logistic regression were performed to examine the significantly associated independent variables (physical performance tests) with falls risk (dependent variable). Approximately 13% older adults were at high risk of falls categorized using PPA. Significant differences (P<0.05) were demonstrated for age, TST, SPPB, FRT, SBT, TUG between high and low falls risk group. A significant (P<0.01) weak correlation was found between PPA and TST (r=0.25), TUG (r=0.27), SBT (r=0.23), SPPB (r=-0.33), and FRT (r=-0.23). Binary logistic regression results demonstrated that SBT measuring postural sways objectively using a balance board was the only significant predictor of physiological falls risk (P<0.05, odds ratio of 2.12). The reference values of physical performance tests in our study may be used as a guide for initial falls screening to categorize high and low physiological falls risk among community-dwelling older adults. A more comprehensive assessment of falls risk can be performed thereafter for more specific intervention of underlying impairments.

  2. Effect of chemical disinfectant on the transverse strength of heat-polymerized acrylic resins subjected to mechanical and chemical polishing: an in vitro study.

    PubMed

    Sharan, Smitha; Kavitha, H R; Konde, Harish; Kalahasti, Deepthi

    2012-05-01

    To evaluate the effect of chemical disinfectant on the transverse strength of heat-polymerized acrylic resins subjected to mechanical and chemical polishing. A total of 256 rectangular specimens (65 * 10 * 3 mm) 128 per resin (Lucitone-199 and Acralyn-H) were fabricated. One side of each specimen was not polished and the other was either mechanically (n = 96) or chemically (n = 96) polished and immersed for 10, 30 and 60 minutes in 2% alkaline glutaraldehyde. Mechanically polished (n = 32) and chemically polished (n = 32) control specimens were immersed only in distilled water. The transverse strength (N/mm(2)) was tested for failure in a universal testing machine, at a crosshead speed of 5 mm/min. Data were statistically analyzed using 2-way ANOVA and Student t-test. chemical polishing resulted in significantly lower transverse strength values than mechanical polishing. Lucitone- 199 resin demonstrated the highest overall transverse strength for the materials tested. Heat-polymerized acrylic resins either mechanically or chemically polished, did not demonstrate significant changes in transverse strength during immersion in the disinfecting solution tested, regardless of time of immersion. Lucitone-199 resin demonstrated the highest overall transverse strength for the materials tested and significantly stronger than Acralyn-H with either type of polishing following immersion in 2% alkaline glutaraldehyde. There is a concern that immersion in chemical solutions often used for cleansing and disinfection of prostheses may undermine the strength and structure of denture base resins. In this study it was observed that, the transverse strength of samples of Lucitone-199 was higher than that of the samples of Acralyn-H. The chances of fracture of the denture made of Lucitone-199 are less than that of dentures made of Acralyn-H. The chemically polished dentures may be more prone to fracture than mechanically polished dentures.

  3. Evaluation of DuPont Qualicon Bax System PCR assay for yeast and mold.

    PubMed

    Wallace, F Morgan; Burns, Frank; Fleck, Lois; Andaloro, Bridget; Farnum, Andrew; Tice, George; Ruebl, Joanne

    2010-01-01

    Evaluations were conducted to test the performance of the BAX System PCR assay which was certified as Performance Tested Method 010902 for screening yeast and mold in yogurt, corn starch, and milk-based powdered infant formula. Method comparison studies performed on samples with low-level inoculates showed that the BAX System demonstrates a sensitivity equivalent to the U.S. Food and Drug Administration's Bacteriological Analytical Manual culture method, but with a significantly shorter time to obtain results. Tests to evaluate inclusivity and exclusivity returned no false-negative and no false-positive results on a diverse panel of isolates, and tests for lot-to-lot variability and tablet stability demonstrated consistent performance. Ruggedness studies determined that none of the factors examined affected the performance of the assay.

  4. Comparing perceived and test-based knowledge of cancer risk and prevention among Hispanic and African Americans: an example of community participatory research.

    PubMed

    Jones, Loretta; Bazargan, Mohsen; Lucas-Wright, Anna; Vadgama, Jaydutt V; Vargas, Roberto; Smith, James; Otoukesh, Salman; Maxwell, Annette E

    2013-01-01

    Most theoretical formulations acknowledge that knowledge and awareness of cancer screening and prevention recommendations significantly influence health behaviors. This study compares perceived knowledge of cancer prevention and screening with test-based knowledge in a community sample. We also examine demographic variables and self-reported cancer screening and prevention behaviors as correlates of both knowledge scores, and consider whether cancer related knowledge can be accurately assessed using just a few, simple questions in a short and easy-to-complete survey. We used a community-partnered participatory research approach to develop our study aims and a survey. The study sample was composed of 180 predominantly African American and Hispanic community individuals who participated in a full-day cancer prevention and screening promotion conference in South Los Angeles, California, on July 2011. Participants completed a self-administered survey in English or Spanish at the beginning of the conference. Our data indicate that perceived and test-based knowledge scores are only moderately correlated. Perceived knowledge score shows a stronger association with demographic characteristics and other cancer related variables than the test-based score. Thirteen out of twenty variables that are examined in our study showed a statistically significant correlation with the perceived knowledge score, however, only four variables demonstrated a statistically significant correlation with the test-based knowledge score. Perceived knowledge of cancer prevention and screening was assessed with fewer items than test-based knowledge. Thus, using this assessment could potentially reduce respondent burden. However, our data demonstrate that perceived and test-based knowledge are separate constructs.

  5. Proof test methodology for composites

    NASA Technical Reports Server (NTRS)

    Wu, Edward M.; Bell, David K.

    1992-01-01

    The special requirements for proof test of composites are identified based on the underlying failure process of composites. Two proof test methods are developed to eliminate the inevitable weak fiber sites without also causing flaw clustering which weakens the post-proof-test composite. Significant reliability enhancement by these proof test methods has been experimentally demonstrated for composite strength and composite life in tension. This basic proof test methodology is relevant to the certification and acceptance of critical composite structures. It can also be applied to the manufacturing process development to achieve zero-reject for very large composite structures.

  6. Innovations in bonding to zirconia based ceramics: Part III. Phosphate monomer resin cements.

    PubMed

    Mirmohammadi, Hesam; Aboushelib, Moustafa N M; Salameh, Ziad; Feilzer, Albert J; Kleverlaan, Cornelis J

    2010-08-01

    To compare the bond strength values and the ranking order of three phosphate monomer containing resin cements using microtensile (microTBS) and microshear (microSBS) bond strength tests. Zirconia discs (Procera Zirconia) were bonded to resin composite discs (Filtek Z250) using three different cements (Panavia F 2.0, RelyX UniCem, and Multilink). Two bond strength tests were used to determine zirconia resin bond strength; microtensile bond strength test (microTBS) and microshear bond strength test (microSBS). Ten specimens were tested for each group (n=10). Two-way analysis of variance (ANOVA) was used to analyze the data (alpha=0.05). There were statistical significant differences in bond strength values and in the ranking order obtained using the two test methods. microTBS reported significant differences in bond strength values, whereas microSBS failed to detect such effect. Both Multilink and Panavia demonstrated basically cohesive failure in the resin cement while RelyX UniCem demonstrated interfacial failure. Based on the findings of this study, the data obtained using either microTBS or microSBS could not be directly compared. microTBS was more sensitive to material differences compared to microSBS which failed to detect such differences. Copyright 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  7. A psychometric study of the Test of Everyday Attention for Children in the Chinese setting.

    PubMed

    Chan, Raymond C K; Wang, Li; Ye, Jiawen; Leung, Winnie W Y; Mok, Monica Y K

    2008-07-01

    To explore the psychometric properties of the Test of Everyday Attention for Children (TEA-Ch) in the context of a Chinese setting. Confirmatory factor analysis was conducted to examine the construct validity of the Chinese version of the TEA-Ch among a group of 232 children without attention deficit hyperactivity disorder (ADHD). Test-retest reliability was tested on a random sub-sample of 20 children at a 4-week interval. Clinical discrimination was also examined by comparing children with and without ADHD (22 in each group) on the performances of the TEA-Ch. The current Chinese sample demonstrated a three-factor solution for attentional performance among children without ADHD, namely selective attention, executive control/switch, and sustained attention (chi(2)(24)=34.56; RMSEA=.044; p=.075). Moreover, the whole test demonstrated acceptable test-retest reliability at a 4-week interval among a small sub-sample. Children with ADHD performed significantly more poorly than healthy controls in most of the subtests of the TEA-Ch. The results of the present study demonstrate that the test items remain useful in China, a culture very different from that in which the test originated. Finally, the TEA-Ch also presents several advantages when compared to other conventional objective measures of attention.

  8. The lepidoptera as predictable communities of herbivores: a test of niche assembly using the moth communities of Morgan-Monroe State Forest

    Treesearch

    Keith S. Summerville; Michael R. Saunders; Jamie L. Lane

    2013-01-01

    The response of forest insect communities to disturbances such as timber harvest likely will depend on the underlying ecological assembly rules that affect community structure. Two competing hypotheses are niche assembly, which seeks to demonstrate significant species-environment correlations, and dispersal-assembly, which seeks to demonstrate spatial autocorrelation...

  9. Status of the NASA's Evolutionary Xenon Thruster (NEXT) Long-Duration Test After 30,352 Hours of Operation

    NASA Technical Reports Server (NTRS)

    Herman, Daniel A.

    2010-01-01

    The NASA s Evolutionary Xenon Thruster (NEXT) program is tasked with significantly improving and extending the capabilities of current state-of-the-art NSTAR thruster. The service life capability of the NEXT ion thruster is being assessed by thruster wear test and life-modeling of critical thruster components, such as the ion optics and cathodes. The NEXT Long-Duration Test (LDT) was initiated to validate and qualify the NEXT thruster propellant throughput capability. The NEXT thruster completed the primary goal of the LDT; namely to demonstrate the project qualification throughput of 450 kg by the end of calendar year 2009. The NEXT LDT has demonstrated 30,352 hr of operation and processed 490 kg of xenon throughput--surpassing the NSTAR Extended Life Test hours demonstrated and more than double the throughput demonstrated by the NSTAR flight-spare. Thruster performance changes have been consistent with a priori predictions. Thruster erosion has been minimal and consistent with the thruster service life assessment, which predicts the first failure mode at greater than 750 kg throughput. The life-limiting failure mode for NEXT is predicted to be loss of structural integrity of the accelerator grid due to erosion by charge-exchange ions.

  10. Nuclear electric propulsion development and qualification facilities

    NASA Technical Reports Server (NTRS)

    Dutt, D. S.; Thomassen, K.; Sovey, J.; Fontana, Mario

    1991-01-01

    This paper summarizes the findings of a Tri-Agency panel consisting of members from the National Aeronautics and Space Administration (NASA), U.S. Department of Energy (DOE), and U.S. Department of Defense (DOD) that were charged with reviewing the status and availability of facilities to test components and subsystems for megawatt-class nuclear electric propulsion (NEP) systems. The facilities required to support development of NEP are available in NASA centers, DOE laboratories, and industry. However, several key facilities require significant and near-term modification in order to perform the testing required to meet a 2014 launch date. For the higher powered Mars cargo and piloted missions, the priority established for facility preparation is: (1) a thruster developmental testing facility, (2) a thruster lifetime testing facility, (3) a dynamic energy conversion development and demonstration facility, and (4) an advanced reactor testing facility (if required to demonstrate an advanced multiwatt power system). Facilities to support development of the power conditioning and heat rejection subsystems are available in industry, federal laboratories, and universities. In addition to the development facilities, a new preflight qualifications and acceptance testing facility will be required to support the deployment of NEP systems for precursor, cargo, or piloted Mars missions. Because the deployment strategy for NEP involves early demonstration missions, the demonstration of the SP-100 power system is needed by the early 2000's.

  11. Dynamic Response Testing in an Electrically Heated Reactor Test Facility

    NASA Astrophysics Data System (ADS)

    Bragg-Sitton, Shannon M.; Morton, T. J.

    2006-01-01

    Non-nuclear testing can be a valuable tool in the development of a space nuclear power or propulsion system. In a non-nuclear test bed, electric heaters are used to simulate the heat from nuclear fuel. Standard testing allows one to fully assess thermal, heat transfer, and stress related attributes of a given system, but fails to demonstrate the dynamic response that would be present in an integrated, fueled reactor system. The integration of thermal hydraulic hardware tests with simulated neutronic response provides a bridge between electrically heated testing and fueled nuclear testing. By implementing a neutronic response model to simulate the dynamic response that would be expected in a fueled reactor system, one can better understand system integration issues, characterize integrated system response times and response characteristics, and assess potential design improvements at a relatively small fiscal investment. Initial system dynamic response testing was demonstrated on the integrated SAFE-100a heat pipe (HP) cooled, electrically heated reactor and heat exchanger hardware, utilizing a one-group solution to the point kinetics equations to simulate the expected neutronic response of the system. Reactivity feedback calculations were then based on a bulk reactivity feedback coefficient and measured average core temperature. This paper presents preliminary results from similar dynamic testing of a direct drive gas cooled reactor system (DDG), demonstrating the applicability of the testing methodology to any reactor type and demonstrating the variation in system response characteristics in different reactor concepts. Although the HP and DDG designs both utilize a fast spectrum reactor, the method of cooling the reactor differs significantly, leading to a variable system response that can be demonstrated and assessed in a non-nuclear test facility. Planned system upgrades to allow implementation of higher fidelity dynamic testing are also discussed. Proposed DDG testing will utilize a higher fidelity point kinetics model to control core power transients, and reactivity feedback will be based on localized feedback coefficients and several independent temperature measurements taken within the core block. This paper presents preliminary test results and discusses the methodology that will be implemented in follow-on DDG testing and the additional instrumentation required to implement high fidelity dynamic testing.

  12. The effects of alternative input devices and repeated exposures on the Test of Basic Aviation Skills (TBAS) performance.

    PubMed

    Momen, Nausheen

    2009-12-01

    The use of computer-based, psychomotor testing systems for personnel selection and classification has gained popularity in the civilian and military worlds in recent years. However, several issues need to be resolved before adopting a computerized, psychomotor test. The purpose of this study was to compare the impact of alternative input devices used for the Test Of Basic Aviation Skills (TBAS) as well as to explore the practice effects of the TBAS. In study 1, participants were administered the TBAS tracking tests once with a throttle and once with foot pedals in a classic test-retest paradigm. The results confirmed that neither of the input devices provided a significant advantage on TBAS performance. In study 2, participants were administered the TBAS twice with a 24-hour interval between testing. The results demonstrated significant practice effects for all the TBAS subtests except for the dichotic listening tests.

  13. Evaluation of a nurse-designed mobile health education application to enhance knowledge of Pap testing.

    PubMed

    Christensen, Stacy

    2014-01-01

    An experimental study was conducted using a 2-group randomized control pretest/ posttest design to determine if knowledge about Pap testing could be increased through use of a nurse-designed mobile smartphone app developed to educate individuals about the Pap test. A 14-item pretest survey of knowledge about Pap tests was distributed to women attending a university in New England. Participants in the intervention group were provided with an Android device on which a digital health education application on Pap testing had been downloaded. The control group was given a standard pamphlet on Pap testing., Paired t test results demonstrated that knowledge scores on the posttest increased significantly in both groups, but were significantly higher in the intervention group. User satisfaction with the app was high. The results of this study may enhance nursing care by informing nurses about a unique way of learning about Pap testing to recommend to patients.

  14. A SAS macro for testing differences among three or more independent groups using Kruskal-Wallis and Nemenyi tests.

    PubMed

    Liu, Yuewei; Chen, Weihong

    2012-02-01

    As a nonparametric method, the Kruskal-Wallis test is widely used to compare three or more independent groups when an ordinal or interval level of data is available, especially when the assumptions of analysis of variance (ANOVA) are not met. If the Kruskal-Wallis statistic is statistically significant, Nemenyi test is an alternative method for further pairwise multiple comparisons to locate the source of significance. Unfortunately, most popular statistical packages do not integrate the Nemenyi test, which is not easy to be calculated by hand. We described the theory and applications of the Kruskal-Wallis and Nemenyi tests, and presented a flexible SAS macro to implement the two tests. The SAS macro was demonstrated by two examples from our cohort study in occupational epidemiology. It provides a useful tool for SAS users to test the differences among three or more independent groups using a nonparametric method.

  15. Effects of SuperUlam on Supporting Concentration and Mood: A Randomized, Double-Blind, Placebo-Controlled Crossover Study.

    PubMed

    Udani, Jay K

    2013-01-01

    Background. SuperUlam is a proprietary blend of natural ingredients aimed at supporting brain health. We aimed to evaluate the effect of SuperUlam on attention and mood in healthy adults. Methods. Twenty healthy individuals aged 35-65 were enrolled in this randomized, double-blind, placebo-controlled, crossover study. Study duration was 3 weeks and consisted of 3 visits. Measurement of cognitive function included computer-based testing of reaction time, complex attention, working memory, sustained attention, and executive functioning. Mood testing was performed via the profile of mood states (POMS) survey and the Chalder fatigue scale. Results. Cognitive function testing demonstrated a significant improvement from baseline in executive functioning, cognitive flexibility, reaction time, and working memory in the product group only (P < 0.05). When comparing the study product to placebo, the data demonstrated a significant decrease in tension, depression, and anger (P < 0.05). There was no significant difference between the product and placebo in the other measures of mood, including vigor, fatigue, confusion, and total mood disturbance. No adverse events were reported. Conclusions. Supplementation with SuperUlam is safe to consume with potential benefits to cognitive function and mood.

  16. Effects of SuperUlam on Supporting Concentration and Mood: A Randomized, Double-Blind, Placebo-Controlled Crossover Study

    PubMed Central

    Udani, Jay K

    2013-01-01

    Background. SuperUlam is a proprietary blend of natural ingredients aimed at supporting brain health. We aimed to evaluate the effect of SuperUlam on attention and mood in healthy adults. Methods. Twenty healthy individuals aged 35–65 were enrolled in this randomized, double-blind, placebo-controlled, crossover study. Study duration was 3 weeks and consisted of 3 visits. Measurement of cognitive function included computer-based testing of reaction time, complex attention, working memory, sustained attention, and executive functioning. Mood testing was performed via the profile of mood states (POMS) survey and the Chalder fatigue scale. Results. Cognitive function testing demonstrated a significant improvement from baseline in executive functioning, cognitive flexibility, reaction time, and working memory in the product group only (P < 0.05). When comparing the study product to placebo, the data demonstrated a significant decrease in tension, depression, and anger (P < 0.05). There was no significant difference between the product and placebo in the other measures of mood, including vigor, fatigue, confusion, and total mood disturbance. No adverse events were reported. Conclusions. Supplementation with SuperUlam is safe to consume with potential benefits to cognitive function and mood. PMID:24371452

  17. A Factor Analytic Validation Study of the Scale of Teachers' Attitudes towards Inclusive Classrooms (STATIC)

    ERIC Educational Resources Information Center

    Nishimura, Trisha Sugita; Busse, Randy T.

    2015-01-01

    General and special education teachers (N = 125) completed the Scale of Teachers' Attitudes towards Inclusive Classrooms (STATIC). The internal consistency of the instrument was strong with an alpha of 0.89. The measure demonstrated excellent test-retest reliability (r = 0.99) and a dependent t-test was non-significant, indicating mean group…

  18. The Development and Demonstration of Multiple Regression Models for Operant Conditioning Questions.

    ERIC Educational Resources Information Center

    Fanning, Fred; Newman, Isadore

    Based on the assumption that inferential statistics can make the operant conditioner more sensitive to possible significant relationships, regressions models were developed to test the statistical significance between slopes and Y intercepts of the experimental and control group subjects. These results were then compared to the traditional operant…

  19. DuPont qualicon BAX system real-time PCR assay for Escherichia coli O157:H7.

    PubMed

    Burns, Frank; Fleck, Lois; Andaloro, Bridget; Davis, Eugene; Rohrbeck, Jeff; Tice, George; Wallace, Morgan

    2011-01-01

    Evaluations were conducted to test the performance of the BAX System Real-Time PCR assay, which was certified as Performance Tested Method 031002 for screening E. coli O157:H7 in ground beef, beef trim, spinach, and lettuce. Method comparison studies performed on samples with low-level inoculates showed that the BAX System demonstrates a sensitivity equivalent or superior to the FDA-BAM and the USDA-FSIS culture methods, but with a significantly shorter time to result. Tests to evaluate inclusivity and exclusivity returned no false-negative and no false-positive results on a diverse panel of isolates, and tests for lot-to-lot variability and tablet stability demonstrated consistent performance. Ruggedness studies determined that none of the factors examined affect the performance of the assay. An accelerated shelf life study determined an initial 36 month shelf life for the test kit.

  20. The Cross-cultural Utility of Foreign- and Locally-derived Normative Data for Three WHO-endorsed Neuropsychological Tests for South African Adolescents

    PubMed Central

    Ferrett, Helen L.; Thomas, Kevin G. F.; Tapert, Susan F.; Carey, Paul D.; Conradie, Simone; Cuzen, Natalie L.; Stein, Dan J.; Fein, George

    2014-01-01

    Interpretation of neuropsychological tests may be hampered by confounding sociodemographic factors and by using inappropriate normative data. We investigated these factors in three tests endorsed by the World Health Organization: the Grooved Pegboard Test (GPT), the Children's Color Trails Test (CCTT), and the WHO/UCLA version of the Auditory Verbal Learning Test (AVLT). In a sample of 12-15-year-old, Afrikaans- and English-speaking adolescents from the Cape Town region of South Africa, analyses of covariance (ANCOVAs) demonstrated that quality of education was the sociodemographic factor with the biggest influence on test performance, and that age also significantly influenced GPT and CCTT performance. Based on those findings, we provide appropriately stratified normative data for the age group in question. Comparisons between diagnostic interpretations made using foreign normative data versus those using the current local data demonstrate that it is imperative to use appropriately stratified normative data to guard against misinterpreting performance. PMID:24526566

  1. The cross-cultural utility of foreign- and locally-derived normative data for three WHO-endorsed neuropsychological tests for South African adolescents.

    PubMed

    Ferrett, Helen L; Thomas, Kevin G F; Tapert, Susan F; Carey, Paul D; Conradie, Simone; Cuzen, Natalie L; Stein, Dan J; Fein, George

    2014-06-01

    Interpretation of neuropsychological tests may be hampered by confounding sociodemographic factors and by using inappropriate normative data. We investigated these factors in three tests endorsed by the World Health Organization: the Grooved Pegboard Test (GPT), the Children's Color Trails Test (CCTT), and the WHO/UCLA version of the Auditory Verbal Learning Test (AVLT). In a sample of 12-15-year-old, Afrikaans- and English-speaking adolescents from the Cape Town region of South Africa, analyses of covariance (ANCOVAs) demonstrated that quality of education was the sociodemographic factor with the biggest influence on test performance, and that age also significantly influenced GPT and CCTT performance. Based on those findings, we provide appropriately stratified normative data for the age group in question. Comparisons between diagnostic interpretations made using foreign normative data versus those using the current local data demonstrate that it is imperative to use appropriately stratified normative data to guard against misinterpreting performance.

  2. Post-Test Inspection of NASA's Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge and Neutralizer Cathodes

    NASA Technical Reports Server (NTRS)

    Shastry, Rohit; Soulas, George C.

    2016-01-01

    The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014 after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for both discharge and neutralizer cathodes. Discharge keeper erosion was found to be significantly reduced from what was observed in the NEXT 2 kh wear test and NSTAR Extended Life Test, providing adequate protection of vital cathode components throughout the test with ample lifetime remaining. The area of the discharge cathode orifice plate that was exposed by the keeper orifice exhibited net erosion, leading to cathode plate material building up in the cathode-keeper gap and causing a thermally-induced electrical short observed during the test. Significant erosion of the neutralizer cathode orifice was also found and is believed to be the root cause of an observed loss in flow margin. Deposition within the neutralizer keeper orifice as well as on the downstream surface was thicker than expected, potentially resulting in a facility-induced impact on the measured flow margin from plume mode. Neutralizer keeper wall erosion on the beam side was found to be significantly lower compared to the NEXT 2 kh wear test, likely due to the reduction in beam extraction diameter of the ion optics that resulted in decreased ion impingement. Results from the post-test inspection have led to some minor thruster design improvements.

  3. Testing a single regression coefficient in high dimensional linear models

    PubMed Central

    Zhong, Ping-Shou; Li, Runze; Wang, Hansheng; Tsai, Chih-Ling

    2017-01-01

    In linear regression models with high dimensional data, the classical z-test (or t-test) for testing the significance of each single regression coefficient is no longer applicable. This is mainly because the number of covariates exceeds the sample size. In this paper, we propose a simple and novel alternative by introducing the Correlated Predictors Screening (CPS) method to control for predictors that are highly correlated with the target covariate. Accordingly, the classical ordinary least squares approach can be employed to estimate the regression coefficient associated with the target covariate. In addition, we demonstrate that the resulting estimator is consistent and asymptotically normal even if the random errors are heteroscedastic. This enables us to apply the z-test to assess the significance of each covariate. Based on the p-value obtained from testing the significance of each covariate, we further conduct multiple hypothesis testing by controlling the false discovery rate at the nominal level. Then, we show that the multiple hypothesis testing achieves consistent model selection. Simulation studies and empirical examples are presented to illustrate the finite sample performance and the usefulness of the proposed method, respectively. PMID:28663668

  4. Testing a single regression coefficient in high dimensional linear models.

    PubMed

    Lan, Wei; Zhong, Ping-Shou; Li, Runze; Wang, Hansheng; Tsai, Chih-Ling

    2016-11-01

    In linear regression models with high dimensional data, the classical z -test (or t -test) for testing the significance of each single regression coefficient is no longer applicable. This is mainly because the number of covariates exceeds the sample size. In this paper, we propose a simple and novel alternative by introducing the Correlated Predictors Screening (CPS) method to control for predictors that are highly correlated with the target covariate. Accordingly, the classical ordinary least squares approach can be employed to estimate the regression coefficient associated with the target covariate. In addition, we demonstrate that the resulting estimator is consistent and asymptotically normal even if the random errors are heteroscedastic. This enables us to apply the z -test to assess the significance of each covariate. Based on the p -value obtained from testing the significance of each covariate, we further conduct multiple hypothesis testing by controlling the false discovery rate at the nominal level. Then, we show that the multiple hypothesis testing achieves consistent model selection. Simulation studies and empirical examples are presented to illustrate the finite sample performance and the usefulness of the proposed method, respectively.

  5. Differences in genotoxic activity of alpha-Ni3S2 on human lymphocytes from nickel-hypersensitized and nickel-unsensitized donors.

    PubMed

    Arrouijal, F Z; Marzin, D; Hildebrand, H F; Pestel, J; Haguenoer, J M

    1992-05-01

    The genotoxic activity of alpha-Ni3S2 was assessed on human lymphocytes from nickel-hypersensitized (SSL) and nickel-unsensitized (USL) subjects. Three genotoxicity tests were performed: the sister chromatid exchange (SCE) test, the metaphase analysis test and the micronucleus test. (i) The SCE test (3-100 micrograms/ml) showed a weak but statistically significant increase in the number of SCE in both lymphocyte types with respect to controls, USL presenting a slightly higher SCE incidence but only at one concentration. (ii) The metaphase analysis test demonstrated a high dose-dependent clastogenic activity of alpha-Ni3S2 in both lymphocyte types. The frequency of chromosomal anomalies was significantly higher in USL than in SSL for all concentrations applied. (iii) The micronucleus test confirmed the dose-dependent clastogenic activity of alpha-Ni3S2 and the differences already observed between USL and SSL, i.e. the number of cells with micronuclei was statistically higher in USL. Finally, the incorporation study with alpha-63Ni3S2 showed a higher uptake of its solubilized fraction by USL. This allows an explanation of the different genotoxic action of nickel on the two cell types. In this study we demonstrated that hypersensitivity has an influence on the incorporation of alpha-Ni3S2 and subsequently on the different induction of chromosomal aberrations in human lymphocytes.

  6. Laboratory based instruction in Pakistan: Comparative evaluation of three laboratory instruction methods in biological science at higher secondary school level

    NASA Astrophysics Data System (ADS)

    Cheema, Tabinda Shahid

    This study of laboratory based instruction at higher secondary school level was an attempt to gain some insight into the effectiveness of three laboratory instruction methods: cooperative group instruction method, individualised instruction method and lecture demonstration method on biology achievement and retention. A Randomised subjects, Pre-test Post-test Comparative Methods Design was applied. Three groups of students from a year 11 class in Pakistan conducted experiments using the different laboratory instruction methods. Pre-tests, achievement tests after the experiments and retention tests one month later were administered. Results showed no significant difference between the groups on total achievement and retention, nor was there any significant difference on knowledge and comprehension test scores or skills performance. Future research investigating a similar problem is suggested.

  7. Effects of a 6-month exercise program pilot study on walking economy, peak physiological characteristics, and walking performance in patients with peripheral arterial disease.

    PubMed

    Crowther, Robert G; Leicht, Anthony S; Spinks, Warwick L; Sangla, Kunwarjit; Quigley, Frank; Golledge, Jonathan

    2012-01-01

    The purpose of this study was to examine the effects of a 6-month exercise program on submaximal walking economy in individuals with peripheral arterial disease and intermittent claudication (PAD-IC). Participants (n = 16) were randomly allocated to either a control PAD-IC group (CPAD-IC, n = 6) which received standard medical therapy, or a treatment PAD-IC group (TPAD-IC; n = 10) which took part in a supervised exercise program. During a graded treadmill test, physiological responses, including oxygen consumption, were assessed to calculate walking economy during submaximal and maximal walking performance. Differences between groups at baseline and post-intervention were analyzed via Kruskal-Wallis tests. At baseline, CPAD-IC and TPAD-IC groups demonstrated similar walking performance and physiological responses. Postintervention, TPAD-IC patients demonstrated significantly lower oxygen consumption during the graded exercise test, and greater maximal walking performance compared to CPAD-IC. These preliminary results indicate that 6 months of regular exercise improves both submaximal walking economy and maximal walking performance, without significant changes in maximal walking economy. Enhanced walking economy may contribute to physiological efficiency, which in turn may improve walking performance as demonstrated by PAD-IC patients following regular exercise programs.

  8. Decomposition of Ag-based soldering alloys used in space maintainers after intra-oral exposure. A retrieval analysis study.

    PubMed

    Soteriou, Despo; Ntasi, Argyro; Papagiannoulis, Lisa; Eliades, Theodore; Zinelis, Spiros

    2014-02-01

    The aim of this study was to evaluate the elemental alterations of Ag soldering alloys used in space maintainers after intra-oral exposure. Twenty devices were fabricated by using two different soldering alloys; US (Dentaurum Universal Silver Solder, n = 10) and OS (Leone Orthodontic Solder, n = 10). All devices were manufactured by the same technician. Surface morphology and elemental quantitative analysis of the soldering alloys before and after intra-oral placement in patients was determined by scanning electron microscopy and energy-dispersive X-ray microanalysis (SEM/EDX). Statistical analysis was performed by t-test, Mann Whitney tests and Pearson's correlation. For all tests a 95% confidence level was used (α = 0.05). Both soldering alloys demonstrated substantially increase in surface roughness after intra-oral aging. Statistical analysis illustrated a significant decrease in the Cu and Zn content after treatment. OS demonstrated higher Cu release than US (p < 0.05). The remaining relative concentrations of Cu and Zn after the treatment did not show any correlation (p > 0.05) with intra-oral exposure time, apart from Zn in OS (r = 0.840, p = 0.04). Both soldering alloys demonstrated a significant Cu and Zn reduction after intra-oral exposure that may raise biocompatibility concerns.

  9. Experimental clean combustor program, phase 2

    NASA Technical Reports Server (NTRS)

    Gleason, C. C.; Rogers, D. W.; Bahr, D. W.

    1976-01-01

    The primary objectives of this three-phase program are to develop technology for the design of advanced combustors with significantly lower pollutant emission levels than those of current combustors, and to demonstrate these pollutant emission reductions in CF6-50C engine tests. The purpose of the Phase 2 Program was to further develop the two most promising concepts identified in the Phase 1 Program, the double annular combustor and the radial/axial staged combustor, and to design a combustor and breadboard fuel splitter control for CF6-50 engine demonstration testing in the Phase 3 Program. Noise measurement and alternate fuels addendums to the basic program were conducted to obtain additional experimental data. Twenty-one full annular and fifty-two sector combustor configurations were evaluated. Both combustor types demonstrated the capability for significantly reducing pollutant emission levels. The most promising results were obtained with the double annular combustor. Rig test results corrected to CF-50C engine conditions produced EPA emission parameters for CO, HC, and NOX of 3.4, 0.4, and 4.5 respectively. These levels represent CO, HC, and NOX reductions of 69, 90, and 42 percent respectively from current combustor emission levels. The combustor also met smoke emission level requirements and development engine performance and installation requirements.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kreutzer, Cory J.; Rugh, John; Tomerlin, Jeff

    Increased market penetration of electric drive vehicles (EDVs) requires overcoming a number of hurdles, including limited vehicle range and the elevated cost in comparison to conventional vehicles. Climate control loads have a significant impact on range, cutting it by over 50% in both cooling and heating conditions. To minimize the impact of climate control on EDV range, the National Renewable Energy Laboratory has partnered with Hyundai America and key industry partners to quantify the performance of thermal load reduction technologies on a Hyundai Sonata plug-in hybrid electric vehicle. Technologies that impact vehicle cabin heating in cold weather conditions and cabinmore » cooling in warm weather conditions were evaluated. Tests included thermal transient and steady-state periods for all technologies, including the development of a new test methodology to evaluate the performance of occupant thermal conditioning. Heated surfaces demonstrated significant reductions in energy use from steady-state heating, including a 29%-59% reduction from heated surfaces. Solar control glass packages demonstrated significant reductions in energy use for both transient and steady-state cooling, with up to a 42% reduction in transient and 12.8% reduction in steady-state energy use for the packages evaluated. Technologies that demonstrated significant climate control load reduction were selected for incorporation into a complete thermal load reduction package. The complete package is set to be evaluated in the second phase of the ongoing project.« less

  11. Iron-Regulated Phospholipase C Activity Contributes to the Cytolytic Activity and Virulence of Acinetobacter baumannii

    PubMed Central

    Fiester, Steven E.; Schmidt, Robert E.; Beckett, Amber C.; Ticak, Tomislav; Carrier, Mary V.; Ghosh, Rajarshi; Ohneck, Emily J.; Metz, Maeva L.; Sellin Jeffries, Marlo K.; Actis, Luis A.

    2016-01-01

    Acinetobacter baumannii is an opportunistic Gram-negative pathogen that causes a wide range of infections including pneumonia, septicemia, necrotizing fasciitis and severe wound and urinary tract infections. Analysis of A. baumannii representative strains grown in Chelex 100-treated medium for hemolytic activity demonstrated that this pathogen is increasingly hemolytic to sheep, human and horse erythrocytes, which interestingly contain increasing amounts of phosphatidylcholine in their membranes. Bioinformatic, genetic and functional analyses of 19 A. baumannii isolates showed that the genomes of each strain contained two phosphatidylcholine-specific phospholipase C (PC-PLC) genes, which were named plc1 and plc2. Accordingly, all of these strains were significantly hemolytic to horse erythrocytes and their culture supernatants tested positive for PC-PLC activity. Further analyses showed that the transcriptional expression of plc1 and plc2 and the production of phospholipase and thus hemolytic activity increased when bacteria were cultured under iron-chelation as compared to iron-rich conditions. Testing of the A. baumannii ATCC 19606T plc1::aph-FRT and plc2::aph isogenic insertion derivatives showed that these mutants had a significantly reduced PC-PLC activity as compared to the parental strain, while testing of plc1::ermAM/plc2::aph demonstrated that this double PC-PLC isogenic mutant expressed significantly reduced cytolytic and hemolytic activity. Interestingly, only plc1 was shown to contribute significantly to A. baumannii virulence using the Galleria mellonella infection model. Taken together, our data demonstrate that both PLC1 and PLC2, which have diverged from a common ancestor, play a concerted role in hemolytic and cytolytic activities; although PLC1 seems to play a more critical role in the virulence of A. baumannii when tested in an invertebrate model. These activities would provide access to intracellular iron stores this pathogen could use during growth in the infected host. PMID:27875572

  12. Test-Enhanced E-Learning Strategies in Postgraduate Medical Education: A Randomized Cohort Study.

    PubMed

    DelSignore, Lisa A; Wolbrink, Traci A; Zurakowski, David; Burns, Jeffrey P

    2016-11-21

    The optimal design of pedagogical strategies for e-learning in graduate and postgraduate medical education remains to be determined. Video-based e-learning use is increasing, with initial research suggesting that taking short breaks while watching videos (independent of answering test questions) may improve learning by focusing attention on the content presented. Interspersed test questions may also improve knowledge acquisition and retention. To examine the effect of interspersed test questions and periodic breaks on immediate knowledge acquisition and retention at 6 months by pediatric residents engaged in video-based e-learning. First- and second-year pediatric residents were randomized to 1 of the following 3 groups: viewing the complete video uninterrupted (full video), viewing the video interrupted with unrelated logic puzzles (logic puzzles), or viewing the video interrupted with brief comprehension test questions (short answer questions). Residents answered pre- and post-tests before and after video viewing, followed by a retention test at 6 months. Primary outcome included comparison of the change in test scores between groups. A total of 49 residents completed the initial testing session. All 3 learning groups had comparable mean increases in immediate knowledge gain, but with no significant differences between groups (F 2,46 =0.35, P=.71). Thirty-five residents completed retention testing with comparable degrees of knowledge retention in the full video and short answer test questions groups (P<.001), but no significant change in the logic puzzles group (F 1,32 =2.44, P=.13). Improved knowledge gain was not demonstrated among residents answering interspersed questions or completing logic puzzles during interrupted online video viewing when compared with residents viewing uninterrupted video content. However, residents who either participated in uninterrupted video viewing or answered interspersed questions during interrupted video viewing demonstrated significant knowledge retention at 6 months. ©Lisa A DelSignore, Traci A Wolbrink, David Zurakowski, Jeffrey P Burns. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 21.11.2016.

  13. [Improving speech comprehension using a new cochlear implant speech processor].

    PubMed

    Müller-Deile, J; Kortmann, T; Hoppe, U; Hessel, H; Morsnowski, A

    2009-06-01

    The aim of this multicenter clinical field study was to assess the benefits of the new Freedom 24 sound processor for cochlear implant (CI) users implanted with the Nucleus 24 cochlear implant system. The study included 48 postlingually profoundly deaf experienced CI users who demonstrated speech comprehension performance with their current speech processor on the Oldenburg sentence test (OLSA) in quiet conditions of at least 80% correct scores and who were able to perform adaptive speech threshold testing using the OLSA in noisy conditions. Following baseline measures of speech comprehension performance with their current speech processor, subjects were upgraded to the Freedom 24 speech processor. After a take-home trial period of at least 2 weeks, subject performance was evaluated by measuring the speech reception threshold with the Freiburg multisyllabic word test and speech intelligibility with the Freiburg monosyllabic word test at 50 dB and 70 dB in the sound field. The results demonstrated highly significant benefits for speech comprehension with the new speech processor. Significant benefits for speech comprehension were also demonstrated with the new speech processor when tested in competing background noise.In contrast, use of the Abbreviated Profile of Hearing Aid Benefit (APHAB) did not prove to be a suitably sensitive assessment tool for comparative subjective self-assessment of hearing benefits with each processor. Use of the preprocessing algorithm known as adaptive dynamic range optimization (ADRO) in the Freedom 24 led to additional improvements over the standard upgrade map for speech comprehension in quiet and showed equivalent performance in noise. Through use of the preprocessing beam-forming algorithm BEAM, subjects demonstrated a highly significant improved signal-to-noise ratio for speech comprehension thresholds (i.e., signal-to-noise ratio for 50% speech comprehension scores) when tested with an adaptive procedure using the Oldenburg sentences in the clinical setting S(0)N(CI), with speech signal at 0 degrees and noise lateral to the CI at 90 degrees . With the convincing findings from our evaluations of this multicenter study cohort, a trial with the Freedom 24 sound processor for all suitable CI users is recommended. For evaluating the benefits of a new processor, the comparative assessment paradigm used in our study design would be considered ideal for use with individual patients.

  14. A New Test Method for Material Flammability Assessment in Microgravity and Extraterrestrial Environments

    NASA Technical Reports Server (NTRS)

    Olson, S. L.; Beeson, H. D.; Haas, J. P.; Baas, J. S.

    2004-01-01

    The standard oxygen consumption (cone) calorimeter (described in ASTM E 1354 and NASA STD 6001 Test 2) is modified to provide a bench-scale test environment that simulates the low velocity buoyant or ventilation flow generated by or around a burning surface in a spacecraft or extraterrestrial gravity level. The Equivalent Low Stretch Apparatus (ELSA) uses an inverted cone geometry with the sample burning in a ceiling fire (stagnation flow) configuration. For a fixed radiant flux, ignition delay times for characterization material PMMA are shown to decrease by a factor of three at low stretch, demonstrating that ignition delay times determined from normal cone tests significantly underestimate the risk in microgravity. The critical heat flux for ignition is found to be lowered at low stretch as the convective cooling is reduced. At the limit of no stretch, any heat flux that exceeds the surface radiative loss at the surface ignition temperature is sufficient for ignition. Regression rates for PMMA increase with heat flux and stretch rate, but regression rates are much more sensitive to heat flux at the low stretch rates, where a modest increase in heat flux of 25 kW/m2 increases the burning rates by an order of magnitude. The global equivalence ratio of these flames is very fuel rich, and the quantity of CO produced in this configuration is significantly higher than standard cone tests. These results [2] demonstrate the ELSA apparatus allows us to conduct normal gravity experiments that accurately and quantifiably evaluate a material s flammability characteristics in the real-use environment of spacecraft or extra-terrestrial gravitational acceleration. These results also demonstrate that current NASA STD 6001 Test 2 (standard cone) is not conservative since it evaluates materials flammability with a much higher inherent buoyant convective flow.

  15. Online pre-race education improves test scores for volunteers at a marathon.

    PubMed

    Maxwell, Shane; Renier, Colleen; Sikka, Robby; Widstrom, Luke; Paulson, William; Christensen, Trent; Olson, David; Nelson, Benjamin

    2017-09-01

    This study examined whether an online course would lead to increased knowledge about the medical issues volunteers encounter during a marathon. Health care professionals who volunteered to provide medical coverage for an annual marathon were eligible for the study. Demographic information about medical volunteers including profession, specialty, education level and number of marathons they had volunteered for was collected. A 15-question test about the most commonly encountered medical issues was created by the authors and administered before and after the volunteers took the online educational course and compared to a pilot study the previous year. Seventy-four subjects completed the pre-test. Those who participated in the pilot study last year (N = 15) had pre-test scores that were an average of 2.4 points higher than those who did not (mean ranks: pilot study = 51.6 vs. non-pilot = 33.9, p = 0.004). Of the 74 subjects who completed the pre-test, 54 also completed the post-test. The overall post-pre mean score difference was 3.8 ± 2.7 (t = 10.5 df = 53 p < 0.001). While subjects with all levels of volunteer experience demonstrated improvement, only change among first time marathon volunteers was significantly different from the others. Subjects reporting all degree/certification levels demonstrated improvement, but no difference in improvement was found between degree/certification levels. In this follow-up to the previous year's pilot study, online education demonstrated a long-term (one-year) increase in test scores. Testing also continued to show short-term improvement in post-course test scores, compared to pre-course test scores. In general, marathon medical volunteers who had no volunteer experience demonstrated greater improvement than those who had prior volunteer experience.

  16. Dry eye disease and work productivity loss in visual display users: the Osaka study.

    PubMed

    Uchino, Miki; Uchino, Yuichi; Dogru, Murat; Kawashima, Motoko; Yokoi, Norihiko; Komuro, Aoi; Sonomura, Yukiko; Kato, Hiroaki; Kinoshita, Shigeru; Schaumberg, Debra A; Tsubota, Kazuo

    2014-02-01

    To estimate the impact of dry eye disease (DED) on work performance and productivity in office workers using visual display terminals (VDTs). Cross-sectional study. Six hundred seventy-two Japanese young and middle-aged office workers using VDTs completed a questionnaire that was designed to measured at-work performance deficits and productivity losses using the Japanese version of the Work Limitations Questionnaire, completed by e-mail. Using the Japanese dry eye diagnostic criteria, respondents were classified into 3 groups: definite DED, probable DED, and non DED. Of the 672 office workers, 553 subjects (82.3%), including 366 men and 187 women, completed the questionnaire and underwent clinical evaluation. As for the total workplace productivity loss, the non DED group demonstrated a loss of 3.56%, those with probable DED demonstrated a loss of 4.06%, and those with definite DED demonstrated a loss of 4.82%, indicating significantly worse performance and productivity (P = .014, trend test). For the 4 subscales, DED was associated with significantly lower on-the-job time management (P = .009, trend test) and combined mental performance and interpersonal functioning (P = .011, trend test). After controlling for age, sex, VDT working hours, and diagnosis of DED, time management, physical demands, and mental and interpersonal functioning showed a significant relationship to DED (each P > .05). Annual DED productivity losses were estimated to be $6160 per employee when measured by total production and $1178 per employee calculated by wage. This study indicated that there is a significant impact of DED on the total productivity of Japanese VDT users. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Advanced Guidance and Control Methods for Reusable Launch Vehicles: Test Results

    NASA Technical Reports Server (NTRS)

    Hanson, John M.; Jones, Robert E.; Krupp, Don R.; Fogle, Frank R. (Technical Monitor)

    2002-01-01

    There are a number of approaches to advanced guidance and control (AG&C) that have the potential for achieving the goals of significantly increasing reusable launch vehicle (RLV) safety/reliability and reducing the cost. In this paper, we examine some of these methods and compare the results. We briefly introduce the various methods under test, list the test cases used to demonstrate that the desired results are achieved, show an automated test scoring method that greatly reduces the evaluation effort required, and display results of the tests. Results are shown for the algorithms that have entered testing so far.

  18. Performance of normal adults and children on central auditory diagnostic tests and their corresponding visual analogs.

    PubMed

    Bellis, Teri James; Ross, Jody

    2011-09-01

    It has been suggested that, in order to validate a diagnosis of (C)APD (central auditory processing disorder), testing using direct cross-modal analogs should be performed to demonstrate that deficits exist solely or primarily in the auditory modality (McFarland and Cacace, 1995; Cacace and McFarland, 2005). This modality-specific viewpoint is controversial and not universally accepted (American Speech-Language-Hearing Association [ASHA], 2005; Musiek et al, 2005). Further, no such analogs have been developed to date, and neither the feasibility of such testing in normally functioning individuals nor the concurrent validity of cross-modal analogs has been established. The purpose of this study was to investigate the feasibility of cross-modal testing by examining the performance of normal adults and children on four tests of central auditory function and their corresponding visual analogs. In addition, this study investigated the degree to which concurrent validity of auditory and visual versions of these tests could be demonstrated. An experimental repeated measures design was employed. Participants consisted of two groups (adults, n=10; children, n=10) with normal and symmetrical hearing sensitivity, normal or corrected-to-normal visual acuity, and no family or personal history of auditory/otologic, language, learning, neurologic, or related disorders. Visual analogs of four tests in common clinical use for the diagnosis of (C)APD were developed (Dichotic Digits [Musiek, 1983]; Frequency Patterns [Pinheiro and Ptacek, 1971]; Duration Patterns [Pinheiro and Musiek, 1985]; and the Random Gap Detection Test [RGDT; Keith, 2000]). Participants underwent two 1 hr test sessions separated by at least 1 wk. Order of sessions (auditory, visual) and tests within each session were counterbalanced across participants. ANOVAs (analyses of variance) were used to examine effects of group, modality, and laterality (for the Dichotic/Dichoptic Digits tests) or response condition (for the auditory and visual Frequency Patterns and Duration Patterns tests). Pearson product-moment correlations were used to investigate relationships between auditory and visual performance. Adults performed significantly better than children on the Dichotic/Dichoptic Digits tests. Results also revealed a significant effect of modality, with auditory better than visual, and a significant modality×laterality interaction, with a right-ear advantage seen for the auditory task and a left-visual-field advantage seen for the visual task. For the Frequency Patterns test and its visual analog, results revealed a significant modality×response condition interaction, with humming better than labeling for the auditory version but the reversed effect for the visual version. For Duration Patterns testing, visual performance was significantly poorer than auditory performance. Due to poor test-retest reliability and ceiling effects for the auditory and visual gap-detection tasks, analyses could not be performed. No cross-modal correlations were observed for any test. Results demonstrated that cross-modal testing is at least feasible using easily accessible computer hardware and software. The lack of any cross-modal correlations suggests independent processing mechanisms for auditory and visual versions of each task. Examination of performance in individuals with central auditory and pan-sensory disorders is needed to determine the utility of cross-modal analogs in the differential diagnosis of (C)APD. American Academy of Audiology.

  19. THE CLINICAL, FUNCTIONAL AND BIOMECHANICAL PRESENTATION OF PATIENTS WITH SYMPTOMATIC HIP ABDUCTOR TENDON TEARS.

    PubMed

    Ebert, Jay R; Retheesh, Theertha; Mutreja, Rinky; Janes, Gregory C

    2016-10-01

    Hip abductor tendon (HAT) tearing is commonly implicated in greater trochanteric pain syndrome (GTPS), though limited information exists on the disability associated with this condition and specific presentation of these patients. To describe the clinical, functional and biomechanical presentation of patients with symptomatic HAT tears. Secondary purposes were to investigate the association between these clinical and functional measures, and to compare the pain and disability reported by HAT tear patients to those with end-stage hip osteoarthritis (OA). Prospective case series. One hundred forty-nine consecutive patients with symptomatic HAT tears were evaluated using the Harris (HHS) and Oxford (OHS) Hip Scores, SF-12, an additional series of 10 questions more pertinent to those with lateral hip pain, active hip range of motion (ROM), maximal isometric hip abduction strength, six-minute walk capacity and 30-second single limb stance (SLS) test. The presence of a Trendelenburg sign and pelvis-on-femur (POF) angle were determined via 2D video analysis. An age matched comparative sample of patients with end-stage hip OA was recruited for comparison of all patient-reported outcome scores. Independent t-tests investigated group and limb differences, while analysis of variance evaluated pain changes during the functional tests. Pearson's correlation coefficients investigated the correlation between clinical measures in the HAT tear group. No differences existed in patient demographics and patient-reported outcome scores between HAT tear and hip OA cohorts, apart from significantly worse SF-12 mental subscale scores (p = 0.032) in the HAT tear group. Patients with HAT tears demonstrated significantly lower (p < 0.05) hip abduction strength and active ROM in all planes of motion on their affected limb. Pain significantly increased throughout the 30-second SLS test for the HAT tear group, with 57% of HAT tear patients demonstrating a positive Trendelenburg sign. POF angle during the test was not significantly associated with pain. Patients with symptomatic HAT tears demonstrate poor function, and report pain and disability similar to or worse than those with end-stage hip OA. This information better defines and differentiates the presentation of these patients. Level 3 case-controlled study, with matched comparison.

  20. The Association Between Fall History and Physical Performance Tests in the Community-Dwelling Elderly: A Cross-Sectional Analysis.

    PubMed

    Kim, Jin Chul; Chon, Jinmann; Kim, Hee Sang; Lee, Jong Ha; Yoo, Seung Don; Kim, Dong Hwan; Lee, Seung Ah; Han, Yoo Jin; Lee, Hyun Seok; Lee, Bae Youl; Soh, Yun Soo; Won, Chang Won

    2017-04-01

    To evaluate the association between baseline characteristics, three physical performance tests and fall history in a sample of the elderly from Korean population. A total of 307 participants (mean age, 76.70±4.85 years) were categorized into one of two groups, i.e., fallers and non-fallers. Fifty-two participants who had reported falling unexpectedly at least once in the previous 12 months were assigned to the fallers group. Physical performance tests included Short Physical Performance Battery (SPPB), Berg Balance Scale (BBS), Timed Up and Go test. The differences between the two study groups were compared and we analyzed the correlations between fall histories and physical performance tests. SPPB demonstrated a significant association with fall history. Although the BBS total scores did not show statistical significance, two dynamic balance test items of BBS (B12 and B13) showed a significant association among fallers. This study suggests that SPPB and two dynamic balance test items of the BBS can be used in screening for risk of falls in an ambulatory elderly population.

  1. The development of in situ fracture toughness evaluation techniques in hydrogen environment

    DOE PAGES

    Wang, John Jy-An; Ren, Fei; Tan, Tin; ...

    2014-12-19

    Reliability of hydrogen pipelines and storage tanks is significantly influenced by the mechanical performance of the structural materials exposed in the hydrogen environment. Fracture behavior and fracture toughness are of specific interest since they are relevant to many catastrophic failures. However, many conventional fracture testing techniques are difficult to be realized under the presence of hydrogen. Thus it is desired to develop novel in situ techniques to study the fracture behavior of structural materials in hydrogen environments. In this study, special testing apparatus were designed to facilitate in situ fracture testing in H 2. A torsional fixture was developed tomore » utilize an emerging fracture testing technique, Spiral Notch Torsion Test (SNTT). The design concepts will be discussed. Preliminary in situ testing results indicated that the exposure to H 2 significantly reduces the fracture toughness of 4340 high strength steels by up to 50 percent. Furthermore, SNTT tests conducted in air demonstrated a significant fracture toughness reduction in samples subject to simulated welding heat treatment using Gleeble, which illustrated the effect of welding on the fracture toughness of this material.« less

  2. Ceramic valve development for heavy-duty low heat rejection diesel engines

    NASA Technical Reports Server (NTRS)

    Weber, K. E.; Micu, C. J.

    1989-01-01

    Monolithic ceramic valves can be successfully operated in a heavy-duty diesel engine, even under extreme low heat rejection operating conditions. This paper describes the development of a silicon nitride valve from the initial design stage to actual engine testing. Supplier involvement, finite element analysis, and preliminary proof of concept demonstration testing played a significant role in this project's success.

  3. Revision ulnar collateral ligament reconstruction using a suspension button fixation technique.

    PubMed

    Lee, Gregory H; Limpisvasti, Orr; Park, Maxwell C; McGarry, Michelle H; Yocum, Lewis A; Lee, Thay Q

    2010-03-01

    Revision ulnar collateral ligament reconstruction remains a challenging problem. The objective of this study was to biomechanically evaluate an ulnar collateral ligament reconstruction technique using a suspension button fixation technique that can be used even in the case of ulnar cortical bone loss. An ulnar suspension fixation technique for ulnar collateral ligament reconstruction can restore elbow kinematics and demonstrate failure strength comparable to that of currently available techniques. Controlled laboratory study. Nine pairs of cadaveric elbows were dissected free of soft tissue and potted. After simulating ulnar cortical bone loss, ulnar collateral ligament reconstruction was performed in 1 elbow of each pair using palmaris longus autograft and a 30-mm RetroButton suspended from the far (lateralmost) ulnar cortex. A docking technique was used for humeral fixation of the graft. Elbow valgus angle was quantified using a Microscribe 3DLX digitizer at multiple elbow flexion angles. Valgus angle was measured with the ulnar collateral ligament intact, transected, and reconstructed. In addition, load-to-failure testing was performed in 1 elbow of each pair. Release of the ulnar collateral ligament caused a significant increase in valgus angle at each flexion angle tested (P < .002). Reconstructed elbows demonstrated no significant differences in valgus angle from the intact elbow at all flexion angles tested. Load-to-failure tests showed that reconstructed elbows had an ultimate torque (10.3 + or - 5.7 N x m) significantly less than intact elbows (26.4 + or - 10.6 N x m) (P = .001). Ulnar collateral ligament reconstruction using a suspension button fixation technique reliably restored elbow kinematics to the intact state. Load-to-failure testing demonstrated comparable fixation strength to several historic controls of primary reconstruction techniques despite the simulated ulnar cortical bone loss. Ulnar collateral ligament reconstruction using a suspension button fixation technique can be considered in the case of ulnar cortical bone loss in a primary or revision setting.

  4. Accurate computation of survival statistics in genome-wide studies.

    PubMed

    Vandin, Fabio; Papoutsaki, Alexandra; Raphael, Benjamin J; Upfal, Eli

    2015-05-01

    A key challenge in genomics is to identify genetic variants that distinguish patients with different survival time following diagnosis or treatment. While the log-rank test is widely used for this purpose, nearly all implementations of the log-rank test rely on an asymptotic approximation that is not appropriate in many genomics applications. This is because: the two populations determined by a genetic variant may have very different sizes; and the evaluation of many possible variants demands highly accurate computation of very small p-values. We demonstrate this problem for cancer genomics data where the standard log-rank test leads to many false positive associations between somatic mutations and survival time. We develop and analyze a novel algorithm, Exact Log-rank Test (ExaLT), that accurately computes the p-value of the log-rank statistic under an exact distribution that is appropriate for any size populations. We demonstrate the advantages of ExaLT on data from published cancer genomics studies, finding significant differences from the reported p-values. We analyze somatic mutations in six cancer types from The Cancer Genome Atlas (TCGA), finding mutations with known association to survival as well as several novel associations. In contrast, standard implementations of the log-rank test report dozens-hundreds of likely false positive associations as more significant than these known associations.

  5. Accurate Computation of Survival Statistics in Genome-Wide Studies

    PubMed Central

    Vandin, Fabio; Papoutsaki, Alexandra; Raphael, Benjamin J.; Upfal, Eli

    2015-01-01

    A key challenge in genomics is to identify genetic variants that distinguish patients with different survival time following diagnosis or treatment. While the log-rank test is widely used for this purpose, nearly all implementations of the log-rank test rely on an asymptotic approximation that is not appropriate in many genomics applications. This is because: the two populations determined by a genetic variant may have very different sizes; and the evaluation of many possible variants demands highly accurate computation of very small p-values. We demonstrate this problem for cancer genomics data where the standard log-rank test leads to many false positive associations between somatic mutations and survival time. We develop and analyze a novel algorithm, Exact Log-rank Test (ExaLT), that accurately computes the p-value of the log-rank statistic under an exact distribution that is appropriate for any size populations. We demonstrate the advantages of ExaLT on data from published cancer genomics studies, finding significant differences from the reported p-values. We analyze somatic mutations in six cancer types from The Cancer Genome Atlas (TCGA), finding mutations with known association to survival as well as several novel associations. In contrast, standard implementations of the log-rank test report dozens-hundreds of likely false positive associations as more significant than these known associations. PMID:25950620

  6. Antibacterial, physical and mechanical properties of flowable resin composites containing zinc oxide nanoparticles.

    PubMed

    Tavassoli Hojati, Sara; Alaghemand, Homayoon; Hamze, Faeze; Ahmadian Babaki, Fateme; Rajab-Nia, Ramazan; Rezvani, Mohammad Bagher; Kaviani, Mehrnoosh; Atai, Mohammad

    2013-05-01

    The aim of this study is evaluating the antibacterial activity of resin composites containing ZnO nanoparticles against Streptococcus mutans and examining their physical and mechanical properties. The properties of flowable resin composites containing 0-5wt.% nano-ZnO are investigated using different tests: Although the agar diffusion test reveals no significant difference between the groups, the direct contact test demonstrates that by increasing the nanoparticle content, the bacterial growth is significantly diminished (p<0.05). In the aging test, however, the antibacterial properties reduce significantly (p<0.05). The flexural strength and compressive modulus remains unchanged by incorporation of nanoparticles (p>0.05) while the compressive strength and flexural modulus significantly increase (p<0.05). The ZnO containing resins show significantly lower depth of cure (p<0.05), and higher bond strength (p<0.05). There is no significant difference between the degrees of conversion, measured by FTIR technique, of the groups (p>0.05). Production of a dental resin composite with antibacterial activity without significant sacrificing effect on the mechanical properties is desirable in dental material science. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  7. Comparison of contemporary occipitocervical instrumentation techniques with and without C1 lateral mass screws.

    PubMed

    Wolfla, Christopher E; Salerno, Simon A; Yoganandan, Narayan; Pintar, Frank A

    2007-09-01

    This study was designed to test the kinematic properties of three occiput-C2 instrumentation constructs with and without supplemental rigid C1 fixation. The results are compared with intact specimens and with constructs incorporating contemporary cabling techniques. Five unembalmed human cadaver specimens underwent range of motion (ROM) testing in the intact condition, followed by destabilization with odontoid osteotomy. Destabilized specimens then underwent ROM testing with each of seven occipitocervical instrumentation constructs, all incorporating occipital screws: C1 and C2 sublaminar cables with cable connectors, C2 pars screws +/- C1 lateral mass screws, C2 lamina screws +/- C1 lateral mass screws, and C1-C2 transarticular screws +/- C1 lateral mass screws. All seven constructs demonstrated significantly lower ROM in all loading modes than intact specimens (P < 0.05). With a single exception, the addition of C1 lateral mass screws to the screw-based constructs produced no significant change in ROM in any of the loading modes. Compared with intact specimens, constructs anchored by C1-C2 transarticular screws demonstrated the greatest decrease in ROM, and those anchored by sublaminar cables demonstrated the least decrease in ROM. Any of the tested screw-based constructs are likely to provide adequate support for the patient with an unstable craniocervical junction. Therefore, the choice of construct should be based on anatomic considerations. The routine incorporation of C1 lateral mass screws into occipitocervical instrumentation constructs does not seem necessary.

  8. Conditional Tests for Localizing Trait Genes

    PubMed Central

    Di, Yanming; Thompson, Elizabeth A.

    2009-01-01

    Background/Aims With pedigree data, genetic linkage can be detected using inheritance vector tests, which explore the discrepancy between the posterior distribution of the inheritance vectors given observed trait values and the prior distribution of the inheritance vectors. In this paper, we propose conditional inheritance vector tests for linkage localization. These conditional tests can also be used to detect additional linkage signals in the presence of previously detected causal genes. Methods For linkage localization, we propose to perform inheritance vector tests conditioning on the inheritance vectors at two positions bounding a test region. We can detect additional linkage signals by conducting a further conditional test in a region with no previously detected genes. We use randomized p values to extend the marginal and conditional tests when the inheritance vectors cannot be completely determined from genetic marker data. Results We conduct simulation studies to compare and contrast the marginal and the conditional tests and to demonstrate that randomized p values can capture both the significance and the uncertainty in the test results. Conclusions The simulation results demonstrate that the proposed conditional tests provide useful localization information, and with informative marker data, the uncertainty in randomized marginal and conditional test results is small. PMID:19439976

  9. Social learning in juvenile lemon sharks, Negaprion brevirostris.

    PubMed

    Guttridge, Tristan L; van Dijk, Sander; Stamhuis, Eize J; Krause, Jens; Gruber, Samuel H; Brown, Culum

    2013-01-01

    Social learning is taxonomically widespread and can provide distinct behavioural advantages, such as in finding food or avoiding predators more efficiently. Although extensively studied in bony fishes, no such empirical evidence exists for cartilaginous fishes. Our aim in this study was to experimentally investigate the social learning capabilities of juvenile lemon sharks, Negaprion brevirostris. We designed a novel food task, where sharks were required to enter a start zone and subsequently make physical contact with a target in order to receive a food reward. Naive sharks were then able to interact with and observe (a) pre-trained sharks, that is, 'demonstrators', or (b) sharks with no previous experience, that is, 'sham demonstrators'. On completion, observer sharks were then isolated and tested individually in a similar task. During the exposure phase observers paired with 'demonstrator' sharks performed a greater number of task-related behaviours and made significantly more transitions from the start zone to the target, than observers paired with 'sham demonstrators'. When tested in isolation, observers previously paired with 'demonstrator' sharks completed a greater number of trials and made contact with the target significantly more often than observers previously paired with 'sham demonstrators'. Such experience also tended to result in faster overall task performance. These results indicate that juvenile lemon sharks, like numerous other animals, are capable of using socially derived information to learn about novel features in their environment. The results likely have important implications for behavioural processes, ecotourism and fisheries.

  10. Effect of incubation temperature and time on the precision of data generated by antibiotic disc diffusion assays.

    PubMed

    Smith, P; Kronvall, G

    2015-07-01

    The influence on the precision of disc diffusion data of the conditions under which the tests were performed was examined by analysing multilaboratory data sets generated after incubation at 35 °C for 18 h, at 28 °C for 24 h and 22 °C for 24 h and 48 h. Analyses of these data sets demonstrated that precision was significantly and progressively decreased as the test temperature was reduced from 35 to 22 °C. Analysis of the data obtained at 22 °C also showed the precision was inversely related to the time of incubation. Temperature and time related decreases in precision were not related to differences in the mean zone sizes of the data sets obtained under these test conditions. Analysis of the zone data obtained at 28 and 22 °C as single laboratory sets demonstrated that reductions of incubation temperature resulted in significant increases in both intralaboratory and interlaboratory variation. Increases in incubation time at 22 °C were, however, associated with statistically significant increases in interlaboratory variation but not with any significant increase in intralaboratory variation. The significance of these observations for the establishment of the acceptable limits of precision of data sets that can be used for the setting of valid epidemiological cut-off values is discussed. © 2014 John Wiley & Sons Ltd.

  11. Local variations in bone mineral density: a comparison of OCT versus x-ray micro-CT

    NASA Astrophysics Data System (ADS)

    Ugryumova, Nadya; Stevens-Smith, Jenna; Scutt, Andrew; Matcher, Stephen J.

    2008-02-01

    We describe variations in the degree of mineralisation within the subchondral bone plate of the equine metacarpophalangeal joint. A comparison of Optical Coherence Tomography, Micro CT, and SEM techniques was performed. These data are compared between sites on a healthy sample and at points on an osteoarthritically degenerated sample. No significant correlation was found between the optical scattering coefficient and the micro-CT derived BMD for comparisons between different sites on the bone surface. Also OCT demonstrated a larger regional variation in scattering coefficient than did micro CT for bone mineral density. This suggests that the optical scattering coefficient of bone is not related solely to the volume-density of calcium-phosphate. Patches of lower optical scattering coefficient were found in the bone structure that was related to the osteoarthritic lesion area on the overlying cartilage. Areas of microcracking, as revealed by both SEM and micro CT produced distinctive granularity in the OCT images. In further experiments, OCT was compared with micro CT and mechanical strength testing (3-point bending) in a small animal model of cardiovascular disease (cholesterol overload in mice). In the cardiovascular diseased mice, micro-CT of the trabecular bone did not demonstrate a significant change in trabecular bone mineral density before and after administration of the high cholesterol diet. However mechanical testing demonstrated a decrease in mechanical strength and OCT demonstrated a corresponding statistically significant decrease in optical scattering of the bone.

  12. Efficacy of the resilience and adjustment intervention after traumatic brain injury: a randomized controlled trial.

    PubMed

    Kreutzer, Jeffrey S; Marwitz, Jennifer H; Sima, Adam P; Mills, Ana; Hsu, Nancy H; Lukow, Herman R

    2018-05-24

    Examine a psychoeducational and skill-building intervention's effectiveness for individuals after traumatic brain injury (TBI), using a two-arm, parallel, randomized, controlled trial with wait-listed control. The Resilience and Adjustment Intervention (RAI) targets adjustment challenges and emphasizes education, skill-building and psychological support. Overall, 160 outpatients were randomly assigned to a treatment or wait-list control (WLC) group. The manualized treatment was delivered in seven 1-h sessions. The Connor-Davidson Resilience Scale (CD-RISC) was the primary outcome measure. Secondary measures included the Mayo Portland Adaptability Inventory-4 (MPAI-4), Brief Symptom Inventory-18 (BSI-18) and 13-Item Stress Test. After adjusting for injury severity, education and time postinjury, the RAI group (N = 75) demonstrated a significantly greater increase in resilience (effect size = 1.03) compared to the WLC group (N = 73). Participants in the RAI group demonstrated more favourable scores on the MPAI-4 Adjustment and Ability Indices, BSI-18 and the 13-item Stress Test. However, only the CD-RISC and BSI-18 demonstrated a clinically significant difference. In addition, RAI participants demonstrated maintenance of gains from pre-treatment to 3-month follow-up; however, only the BSI-18 maintained a clinically significant difference. Investigation provided evidence that a resilience-focused intervention can improve psychological health and adjustment after TBI. Additional research is needed to ascertain the longer term benefits of intervention and the efficacy of alternative delivery methods (e.g., via telephone, Internet).

  13. Update from C3RS lessons learned team : four demonstration pilots.

    DOT National Transportation Integrated Search

    2014-07-01

    The Federal Railroad Administration (FRA) believes that, in addition to process and technology innovations, human-factors-based solutions can significantly contribute to improving safety in the railroad industry. To test this assumption, FRA implemen...

  14. Qualification of Commercial XIPS(R) Ion Thrusters for NASA Deep Space Missions

    NASA Technical Reports Server (NTRS)

    Goebel, Dan M.; Polk, James E.; Wirz, Richard E.; Snyder, J.Steven; Mikellides, Ioannis G.; Katz, Ira; Anderson, John

    2008-01-01

    Electric propulsion systems based on commercial ion and Hall thrusters have the potential for significantly reducing the cost and schedule-risk of Ion Propulsion Systems (IPS) for deep space missions. The large fleet of geosynchronous communication satellites that use solar electric propulsion (SEP), which will approach 40 satellites by year-end, demonstrates the significant level of technical maturity and spaceflight heritage achieved by the commercial IPS systems. A program to delta-qualify XIPS(R) ion thrusters for deep space missions is underway at JPL. This program includes modeling of the thruster grid and cathode life, environmental testing of a 25-centimeter electromagnetic (EM) thruster over DAWN-like vibe and temperature profiles, and wear testing of the thruster cathodes to demonstrate the life and benchmark the model results. This paper will present the delta-qualification status of the XIPS thruster and discuss the life and reliability with respect to known failure mechanisms.

  15. Reynolds averaged turbulence modelling using deep neural networks with embedded invariance

    DOE PAGES

    Ling, Julia; Kurzawski, Andrew; Templeton, Jeremy

    2016-10-18

    There exists significant demand for improved Reynolds-averaged Navier–Stokes (RANS) turbulence models that are informed by and can represent a richer set of turbulence physics. This paper presents a method of using deep neural networks to learn a model for the Reynolds stress anisotropy tensor from high-fidelity simulation data. A novel neural network architecture is proposed which uses a multiplicative layer with an invariant tensor basis to embed Galilean invariance into the predicted anisotropy tensor. It is demonstrated that this neural network architecture provides improved prediction accuracy compared with a generic neural network architecture that does not embed this invariance property.more » Furthermore, the Reynolds stress anisotropy predictions of this invariant neural network are propagated through to the velocity field for two test cases. For both test cases, significant improvement versus baseline RANS linear eddy viscosity and nonlinear eddy viscosity models is demonstrated.« less

  16. Reynolds averaged turbulence modelling using deep neural networks with embedded invariance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ling, Julia; Kurzawski, Andrew; Templeton, Jeremy

    There exists significant demand for improved Reynolds-averaged Navier–Stokes (RANS) turbulence models that are informed by and can represent a richer set of turbulence physics. This paper presents a method of using deep neural networks to learn a model for the Reynolds stress anisotropy tensor from high-fidelity simulation data. A novel neural network architecture is proposed which uses a multiplicative layer with an invariant tensor basis to embed Galilean invariance into the predicted anisotropy tensor. It is demonstrated that this neural network architecture provides improved prediction accuracy compared with a generic neural network architecture that does not embed this invariance property.more » Furthermore, the Reynolds stress anisotropy predictions of this invariant neural network are propagated through to the velocity field for two test cases. For both test cases, significant improvement versus baseline RANS linear eddy viscosity and nonlinear eddy viscosity models is demonstrated.« less

  17. [Comparative study of the performance of leather and plastic skate boots].

    PubMed

    Roy, B; Grenier, R

    1982-03-01

    The authors have tried to demonstrate the influence of leather skate boots and plastic boots on the performance of Atome hockey players. Speed tests and joint flexibility tests by means of rotentgenograms showed that besides the speed tests where the leather boot appeared to perform a little better than the plastic boot, no significant difference could be found between both types of boots. It seems to be more a matter of individual choice and adaptation.

  18. Engineering Development Program of a Closed Aluminum-Oxygen Semi-cell System for an Unmanned Underwater Vehicle: An Update

    NASA Technical Reports Server (NTRS)

    Gregg, Dane W.; Hall, Susan E.

    1996-01-01

    Most emerging unmanned undersea vehicle (UUV) missions require significantly longer range and endurance than is achievable with existing battery technology. The Aluminum-Oxygen (Al-O2) semi-cell is a candidate technology capable of providing a significant improvement in endurance compared to the silver-zinc battery technology currently in use in UUVs and compares favorably to other proposed UUV power systems not only in performance, but also in safety and logistics. An Al-O2 semi-cell system is under development, consisting of a cell stack, gas management, oxygen storage, electrolyte management coolant and controller subsystems. It is designed to replace the existing silver-zinc battery and meet existing weight, volume, electrical and thermal requirements, therefore minimizing modification to the UUV. A detailed system design is complete. A component and material endurance test to evaluate compatibility and reliability of various materials and components is complete. Sub=scale (short stack) system testing is complete. A full-scale demonstration unit is now under construction for testing in the second half of 1995. The full scale demonstration test will simulate environmental conditions of the operational system. This paper summarizes the results of the extensive short stack and endurance test programs, describes the plan for full-scale testing, and concludes with a brief discussion of future directions for this technology.

  19. Respiratory muscle endurance after training in athletes and non-athletes: A systematic review and meta-analysis.

    PubMed

    Sales, Ana Tereza do N; Fregonezi, Guilherme A de F; Ramsook, Andrew H; Guenette, Jordan A; Lima, Illia Nadinne D F; Reid, W Darlene

    2016-01-01

    The objectives of this systematic review was to evaluate the effects of respiratory muscle training (RMT) on respiratory muscle endurance (RME) and to determine the RME test that demonstrates the most consistent changes after RMT. Electronic searches were conducted in EMBASE, MEDLINE, COCHRANE CENTRAL, CINHAL and SPORTDiscus. The PEDro scale was used for quality assessment and meta-analysis were performed to compare effect sizes of different RME tests. Twenty studies met the inclusion criteria. Isocapnic hyperpnea training was performed in 40% of the studies. Meta-analysis showed that RMT improves RME in athletes (P = 0.0007) and non-athletes (P = 0.001). Subgroup analysis showed differences among tests; maximal sustainable ventilatory capacity (MSVC) and maximal sustainable threshold loading tests demonstrated significant improvement after RMT (P = 0.007; P = 0.003 respectively) compared to the maximal voluntary ventilation (MVV) (P = 0.11) in athletes whereas significant improvement after RMT was only shown by MSVC in non-athletes. The effect size of MSVC was greater compared to MVV in studies that performed both tests. The meta-analysis results provide evidence that RMT improves RME in athletes and non-athletes and MSVC test that examine endurance over several minutes are more sensitive to improvement after RMT. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Marital status as a predictor of survival in patients with human papilloma virus-positive oropharyngeal cancer.

    PubMed

    Rubin, Samuel J; Kirke, Diana N; Ezzat, Waleed H; Truong, Minh T; Salama, Andrew R; Jalisi, Scharukh

    Determine whether marital status is a significant predictor of survival in human papillomavirus-positive oropharyngeal cancer. A single center retrospective study included patients diagnosed with human papilloma virus-positive oropharyngeal cancer at Boston Medical Center between January 1, 2010 and December 30, 2015, and initiated treatment with curative intent at Boston Medical Center. Demographic data and tumor-related variables were recorded. Univariate analysis was performed using a two-sample t-test, chi-squared test, Fisher's exact test, and Kaplan Meier curves with a log rank test. Multivariate survival analysis was performed using a Cox regression model. A total of 65 patients were included in the study with 24 patients described as married and 41 patients described as single. There was no significant difference in most demographic variables or tumor related variables between the two study groups, except single patients were significantly more likely to have government insurance (p=0.0431). Furthermore, there was no significant difference in 3-year overall survival between married patients and single patients (married=91.67% vs single=87.80%; p=0.6532) or 3-year progression free survival (married=79.17% vs single=85.37%; p=0.8136). After adjusting for confounders including age, sex, race, insurance type, smoking status, treatment, and AJCC combined pathologic stage, marital status was not a significant predictor of survival [HR=0.903; 95% CI (0.126,6.489); p=0.9192]. Although previous literature has demonstrated that married patients with head and neck cancer have a survival benefit compared to single patients with head and neck cancer, we were unable to demonstrate the same survival benefit in a cohort of patients with human papilloma virus-positive oropharyngeal cancer. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Evaluation of gloss changes of two denture acrylic resin materials in four different beverages.

    PubMed

    Keyf, Filiz; Etikan, Ilker

    2004-03-01

    The primary disadvantages of the materials which are used in construction of complete and removable partial dentures is that their esthetic, physical and mechanical properties change rapidly with time in the oral environment. For esthetics, color stability is one of the criteria that needs careful attention. Color may provide important information on the serviceability of these materials. Color change affects the gloss of these materials. The objective of the present study was to determine the gloss changes resulting from the testing process in four different beverages in one heat-polymerized denture base resin and one cold-polymerized denture base repair resin. Thirty-six samples were fabricated for each material. Each sample had a smooth polished and a rough unpolished surface. The gloss measurements were made with a glossmeter before testing. Four different beverages (tea, coffee, cola and cherry juice) were used for testing. Two angles of illumination (20 and 60 degrees) were used for the gloss measurements. The samples were immersed in water, tea, coffee, cola and cherry juice solutions. The gloss of the samples was measured again with the glossmeter at the end of the 45th day and 135th day of testing. The arithmetic mean and standard deviation of each of the samples were calculated and compared with each other statistically by using the Wilcoxon test (within times) (p < or = 0.05 significant), the Kruskal-Wallis analysis of variance (p < or = 0.05 significant) and the Mann-Whitney U-test with Bonforoni correction (when the difference between the samples was significant) (p < or = 0.05 significant). The results of this study revealed that gloss changes occurred after testing in heat-polymerized denture base resin and cold-polymerized denture base repair resin. The significance of the gloss changes exhibited by each sample, kept for different lengths of time in the same solution, were compared using the Wilcoxon test. The results were statistically significant (p < or = 0.05). According to the Kruskal-Wallis analysis of variance, the difference between measurements for angles of illumination was statistically significant (p < or = 0.05). Also according to the Mann-Whitney U-test, the difference between two polished surfaces or two unpolished surfaces was statistically insignificant (p > 0.05), but the difference between smooth polished and rough unpolished surfaces was statistically significant (p < or = 0.05). It was found that either the gloss of heat-polymerized denture base resin or the gloss of cold-polymerized denture base repair resin was affected by tested agents, and the four beverages demonstrated noticeable gloss changes. Cherry juice demonstrated the least change, while tea exhibited the greatest change.

  2. Sex-Based Differences in Cognitive Deficits and Symptom Reporting Among Acutely Concussed Adolescent Lacrosse and Soccer Players.

    PubMed

    Sandel, Natalie K; Schatz, Philip; Goldberg, Kenneth B; Lazar, Mary

    2017-03-01

    Research on the acute effects of a concussion among lacrosse players is limited, and postconcussion patterns between male and female athletes have yet to be clearly established. Differences in the style of play and protective gear worn among male and female lacrosse players potentially confound a direct comparison of sex-based differences in this population. To explore sex-based differences in postconcussive neurocognitive functioning and symptom reporting outcomes in concussed adolescent male and female lacrosse players compared with a group of soccer players. Cohort study; Level of evidence, 3. A total of 224 adolescent lacrosse players (112 male, 112 female) aged 13 to 17 years (mean [±SD] age, 15.43 ± 1.09 years) were included in this study. A comparison group of soccer players was added and matched to lacrosse players based on age and sex to address confounding sport differences in male and female versions of lacrosse. All athletes underwent baseline and postinjury testing within 3 days of an injury using the Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) tool. Data were analyzed at baseline using a multivariate analysis of variance (MANOVA) with sport and sex as between-participant factors. A 2 × 2 × 2 mixed-factorial MANOVA was also conducted for sex and sport comparisons at baseline versus after a concussion. Ancillary analyses evaluated sex-based differences in exceeded reliable change indices (RCIs) using an independent-samples t test and established postinjury cutoff scores reflective of a protracted recovery using chi-square tests. All athletes had a significantly worse cognitive profile and greater endorsement of symptoms after an injury ( F 5,216 = 30.30, P < .001, η ρ 2 = .41). Sport yielded a significant main effect ( F 5,216 = 2.36, P = .04, η ρ 2 = .05), but subsequent univariate analyses were nonsignificant ( P > .05) across all neurocognitive and symptom outcome variables. Likewise, there were no significant interaction effects for sport × time ( F 5,216 = 1.46, P = .21, η ρ 2 = .03) or sport × sex × time ( F 5,216 = 2.09, P = .07, η ρ 2 = .05), indicating that lacrosse and soccer players respond similarly on neurocognitive testing and symptom reporting after sustaining a concussion. Regarding sex-based differences, female athletes had a significantly greater neurocognitive decline and increased symptoms after a concussion relative to male athletes, regardless of the sport type (sex × time interaction effect: F 5,216 = 3.86, P = .002, η ρ 2 = .08), with the relationship between concussions and sex demonstrating a medium- to large-sized effect. Female athletes demonstrated a significantly greater number of exceeded RCIs ( t(216.16) = -3.732, P < .001), with 59% of male and 74% of female athletes with at least 1 RCI decline. Approximately 13% of male athletes, compared with 30% of female athletes, demonstrated scores indicative of protracted recovery at a 75% sensitivity (χ 2 (1, N = 224) = 9.43, P = .002). Athletes performed more poorly on computerized cognitive screening tools and reported greater symptoms after an acute concussion relative to their baseline performance. Female sex may be a modifier of an acute concussion outcome, given that female athletes in this study performed significantly worse than male athletes across all neurocognitive measures and reported greater symptoms relative to their baseline testing compared with male athletes, regardless of the sport played. Female athletes were also more likely than male athletes to demonstrate scores on neurocognitive testing that exceeded reliable change cutoffs and were predictive of a protracted recovery. The practical significance of these findings should be further verified by prospective longitudinal research given the medium- to large-sized effect demonstrated for the overall relationship between sex and concussions.

  3. Validity of the Hum Test, a Simple and Reliable Alternative to the Weber Test.

    PubMed

    Ahmed, Omar H; Gallant, Sara C; Ruiz, Ryan; Wang, Binhuan; Shapiro, William H; Voigt, Erich P

    2018-06-01

    To compare the diagnostic performance of the Hum Test against the Weber Test using pure tone audiometry (PTA) as the "gold standard" comparator. 29 participants with normal hearing of ages 18 to 35 without any history of hearing abnormalities or otologic conditions were enrolled. Subjects underwent three tests (Hum Test, Weber Test, and PTA) across two conditions: with an ear plug in one ear (side randomized) and without ear plugs. When examining the ability of the Hum Test to detect simulated conductive hearing loss (CHL), the test had a sensitivity of 89.7% and specificity of 100% with high pitched humming and 93.1% and 100%, respectively, with low pitched humming. The Weber Test had a sensitivity and specificity of 96.6% and 100%, respectively. McNemar's test demonstrated agreement between the Hum Test, performed with either high pitched ( P = .32) or low pitched ( P = .56) humming, and the Weber Test. Receiver operating characteristic (ROC) curves for the Hum Test (both high and low pitched) and Weber test were compared and demonstrated no statistically significant difference. The Hum Test is comparable to the Weber Test with regards to its sensitivity, specificity, and diagnostic accuracy in assessing new onset unilateral CHL in previously normal hearing subjects.

  4. Results of shuttle EMU thermal vacuum tests incorporating an infrared imaging camera data acquisition system

    NASA Technical Reports Server (NTRS)

    Anderson, James E.; Tepper, Edward H.; Trevino, Louis A.

    1991-01-01

    Manned tests in Chamber B at NASA JSC were conducted in May and June of 1990 to better quantify the Space Shuttle Extravehicular Mobility Unit's (EMU) thermal performance in the cold environmental extremes of space. Use of an infrared imaging camera with real-time video monitoring of the output significantly added to the scope, quality and interpretation of the test conduct and data acquisition. Results of this test program have been effective in the thermal certification of a new insulation configuration and the '5000 Series' glove. In addition, the acceptable thermal performance of flight garments with visually deteriorated insulation was successfully demonstrated, thereby saving significant inspection and garment replacement cost. This test program also established a new method for collecting data vital to improving crew thermal comfort in a cold environment.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yashchuk, Valeriy V; Conley, Raymond; Anderson, Erik H.

    We discuss the results of SEM and TEM measurements with the BPRML test samples fabricated from a BPRML (WSi2/Si with fundamental layer thickness of 3 nm) with a Dual Beam FIB (focused ion beam)/SEM technique. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize x-raymore » microscopes. Corresponding work with x-ray microscopes is in progress.« less

  6. Solid Polymer Electrolyte Fuel Cell Technology Program

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Work is reported on phase 5 of the Solid Polymer Electrolyte (SPE) Fuel Cell Technology Development program. The SPE fuel cell life and performance was established at temperatures, pressures, and current densities significantly higher than those previously demonstrated in sub-scale hardware. Operation of single-cell Buildup No. 1 to establish life capabilities of the full-scale hardware was continued. A multi-cell full-scale unit (Buildup No. 2) was designed, fabricated, and test evaluated laying the groundwork for the construction of a reactor stack. A reactor stack was then designed, fabricated, and successfully test-evaluated to demonstrate the readiness of SPE fuel cell technology for future space applications.

  7. Association between physiological falls risk and physical performance tests among community-dwelling older adults

    PubMed Central

    Singh, Devinder KA; Pillai, Sharmila GK; Tan, Sin Thien; Tai, Chu Chiau; Shahar, Suzana

    2015-01-01

    Background Physical performance and balance declines with aging and may lead to increased risk of falls. Physical performance tests may be useful for initial fall-risk screening test among community-dwelling older adults. Physiological profile assessment (PPA), a composite falls risk assessment tool is reported to have 75% accuracy to screen for physiological falls risk. PPA correlates with Timed Up and Go (TUG) test. However, the association between many other commonly used physical performance tests and PPA is not known. The aim of the present study was to examine the association between physiological falls risk measured using PPA and a battery of physical performance tests. Methods One hundred and forty older adults from a senior citizens club in Kuala Lumpur, Malaysia (94 females, 46 males), aged 60 years and above (65.77±4.61), participated in this cross-sectional study. Participants were screened for falls risk using PPA. A battery of physical performance tests that include ten-step test (TST), short physical performance battery (SPPB), functional reach test (FRT), static balance test (SBT), TUG, dominant hand-grip strength (DHGS), and gait speed test (GST) were also performed. Spearman’s rank correlation and binomial logistic regression were performed to examine the significantly associated independent variables (physical performance tests) with falls risk (dependent variable). Results Approximately 13% older adults were at high risk of falls categorized using PPA. Significant differences (P<0.05) were demonstrated for age, TST, SPPB, FRT, SBT, TUG between high and low falls risk group. A significant (P<0.01) weak correlation was found between PPA and TST (r=0.25), TUG (r=0.27), SBT (r=0.23), SPPB (r=−0.33), and FRT (r=−0.23). Binary logistic regression results demonstrated that SBT measuring postural sways objectively using a balance board was the only significant predictor of physiological falls risk (P<0.05, odds ratio of 2.12). Conclusion The reference values of physical performance tests in our study may be used as a guide for initial falls screening to categorize high and low physiological falls risk among community-dwelling older adults. A more comprehensive assessment of falls risk can be performed thereafter for more specific intervention of underlying impairments. PMID:26316727

  8. Identification of Psilocybe cubensis spore allergens by immunoprinting.

    PubMed

    Helbling, A; Horner, W E; Lehrer, S B

    1993-01-01

    Previous studies established that Psilocybe cubensis contains potent allergens, and that a significant percentage of atopic subjects were sensitized to P. cubensis spores. The objective of this study was to identify P. cubensis spore allergens using isoelectric focusing (IEF) and sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) immunoprinting. Coomassie blue staining of IEF gels detected approximately 20 bands between pI 3.6 and 9.3. Immunoprints obtained with 15 P. cubensis skin test- and RAST-positive sera revealed 13 IgE-binding bands; the most reactive were at pI 5.0 (80%), 5.6 (87%), 8.7 (80%) and 9.3 (100%). SDS-PAGE resolved 27 proteins ranging from about 13 to 112 kD. SDS-PAGE immunoprints conducted with 11 skin test- and RAST-positive sera demonstrated 18 IgE-binding bands; most sera reacted to 16 (82%), 35 (100%) and 76 kD (91%) allergens. Both electrophoretic procedures demonstrated a single allergen (at pI 9.3 and 35 kD) that reacted with all sera tested. This study corroborates the allergenic significance of P. cubensis spores and identifies the allergens of greatest importance.

  9. LTP varies across the estrous cycle: enhanced synaptic plasticity in proestrus rats.

    PubMed

    Warren, S G; Humphreys, A G; Juraska, J M; Greenough, W T

    1995-12-12

    Previous studies have shown that the number of dendritic spines and synapses in hippocampal CA1 stratum radiatum decreases more than 30% between the proestrus (high estrogen) and estrus (low estrogen) phases of the rat estrous cycle [10,27]. In the present study, we investigated whether hippocampal synaptic plasticity, as measured by long-term potentiation (LTP), might also vary across the estrous cycle of the female rat. Male rats, and female rats at each phase of the estrous cycle were tested in either the morning or afternoon. There were no significant group differences in the pre-LTP I/O curves. However, females examined during the afternoon of proestrus, the phase during which prior studies indicate synapse number to be highest, demonstrated the greatest degree of potentiation. Diestrus, proestrus and estrus females tested in the morning demonstrated similar amounts of potentiation. There were also significant differences in post-LTP I/O curves between the afternoon proestrus females and males tested in the afternoon. These results suggest that gonadal hormones, interacting with the time of day, may regulate neural processes underlying learning and memory.

  10. Fertility of male adult rats submitted to forced swimming stress.

    PubMed

    Mingoti, G Z; Pereira, R N; Monteiro, C M R

    2003-05-01

    We investigated whether stress interferes with fertility during adulthood. Male Wistar rats (weighing 220 g in the beginning of the experiment) were forced to swim for 3 min in water at 32 degrees C daily for 15 days. Stress was assessed by the hot-plate test after the last stressing session. To assess fertility, control and stressed males (N = 15 per group) were mated with sexually mature normal females. Males were sacrificed after copulation. Stress caused by forced swimming was demonstrated by a significant increase in the latency of the pain response in the hot-plate test (14.6 +/- 1.25 s for control males vs 26.0 +/- 1.53 s for stressed males, P = 0.0004). No changes were observed in body weight, testicular weight, seminal vesicle weight, ventral prostate weight or gross histological features of the testes of stressed males. Similarly, no changes were observed in fertility rate, measured by counting live fetuses in the uterus of normal females mated with control and stressed males; no dead or incompletely developed fetuses were observed in the uterus of either group. In contrast, there was a statistically significant decrease in spermatid production demonstrated by histometric evaluation (154.96 +/- 5.41 vs 127.02 +/- 3.95 spermatids per tubular section for control and stressed rats, respectively, P = 0.001). These data demonstrate that 15 days of forced swimming stress applied to adult male rats did not impair fertility, but significantly decreased spermatid production. This suggests that the effect of stress on fertility should not be assessed before at least the time required for one cycle of spermatogenesis.

  11. Demonstration of transparent solar array module design

    NASA Technical Reports Server (NTRS)

    Pack, G. J.

    1984-01-01

    This report discusses the design, development, fabrication and testing of IR transparent solar array modules. Three modules, consisting of a baseline design using back surface reflector cells, and two modules using gridded back contact, IR transparent cells, were subjected to vacuum thermal balance testing to verify analytical predictions of lower operating emperature and increased efficiency. As a result of this test program, LMSC has verified that a significant degree of IR transparency can be designed into a flexible solar array. Test data correlates with both steady state and transient thermal analysis.

  12. Analyzing Real-World Light Duty Vehicle Efficiency Benefits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonder, Jeffrey; Wood, Eric; Chaney, Larry

    Off-cycle technologies represent an important pathway to achieve real-world fuel savings, through which OEMs can potentially receive credit toward CAFE compliance. DOE national labs such as NREL are well positioned to provide objective input on these technologies using large, national data sets in conjunction with OEM- and technology-specific testing. This project demonstrates an approach that combines vehicle testing (dynamometer and on-road) with powertrain modeling and simulation over large, representative datasets to quantify real-world fuel economy. The approach can be applied to specific off-cycle technologies (engine encapsulation, start/stop, connected vehicle, etc.) in A/B comparisons to support calculation of realistic real-world impacts.more » Future work will focus on testing-based A/B technology comparisons that demonstrate the significance of this approach.« less

  13. Performance and Life Tests of a Regenerative Blower for EVA Suit Ventilation

    NASA Technical Reports Server (NTRS)

    Izenson, Mike; Chen, Weibo; Paul, Heather L.; Jennings, Mallory A.

    2011-01-01

    Ventilation fans for future space suits must meet demanding performance specifications, satisfy stringent safety requirements for operation in an oxygen atmosphere, and be able to increase output to operate in buddy mode. A regenerative blower is an attractive choice due to its ability to meet these requirements at low operating speed. This paper describes progress in the development and testing of a regenerative blower designed to meet requirements for ventilation subsystems in a future space suit Portable Life Support Systems (PLSS). The blower assembly includes a custom-designed motor that has significantly improved in efficiency during this development effort. The blower was tested at both nominal and buddy mode operating points and head/flow performance and power consumption were measured. The blower was operated for over 1000 hours to demonstrate safe operation in an oxygen test loop at prototypical pressures. In addition, the blower demonstrated operation with the introduction of simulated lunar dust.

  14. Evaluation of microtensile and tensile bond strength tests determining effects of erbium, chromium: yttrium-scandium-gallium-garnet laser pulse frequency on resin-enamel bonding.

    PubMed

    Yildirim, T; Ayar, M K; Yesilyurt, C; Kilic, S

    2016-01-01

    The aim of the present study was to compare two different bond strength test methods (tensile and microtensile) in investing the influence of erbium, chromium: yttrium-scandium-gallium-garnet (Er, Cr: YSGG) laser pulse frequency on resin-enamel bonding. One-hundred and twenty-five bovine incisors were used in the present study. Two test methods were used: Tensile bond strength (TBS; n = 20) and micro-TBS (μTBS; n = 5). Those two groups were further split into three subgroups according to Er, Cr: YSGG laser frequency (20, 35, and 50 Hz). Following adhesive procedures, microhybrid composite was placed in a custom-made bonding jig for TBS testing and incrementally for μTBS testing. TBS and μTBS tests were carried out using a universal testing machine and a microtensile tester, respectively. Analysis of TBS results showed that means were not significantly different. For μTBS, the Laser-50 Hz group showed the highest bond strength (P < 0.05), and increasing frequency significantly increased bond strength (P < 0.05). Comparing the two tests, the μTBS results showed higher means and lower standard deviations. It was demonstrated that increasing μTBS pulse frequency significantly improved immediate bond strength while TBS showed no significant effect. It can, therefore, be concluded that test method may play a significant role in determining optimum laser parameters for resin bonding.

  15. Design and development of a prototype platform for gait analysis

    NASA Astrophysics Data System (ADS)

    Diffenbaugh, T. E.; Marti, M. A.; Jagani, J.; Garcia, V.; Iliff, G. J.; Phoenix, A.; Woolard, A. G.; Malladi, V. V. N. S.; Bales, D. B.; Tarazaga, P. A.

    2017-04-01

    The field of event classification and localization in building environments using accelerometers has grown significantly due to its implications for energy, security, and emergency protocols. Virginia Tech's Goodwin Hall (VT-GH) provides a robust testbed for such work, but a reduced scale testbed could provide significant benefits by allowing algorithm development to occur in a simplified environment. Environments such as VT-GH have high human traffic that contributes external noise disrupting test signals. This paper presents a design solution through the development of an isolated platform for data collection, portable demonstrations, and the development of localization and classification algorithms. The platform's success was quantified by the resulting transmissibility of external excitation sources, demonstrating the capabilities of the platform to isolate external disturbances while preserving gait information. This platform demonstrates the collection of high-quality gait information in otherwise noisy environments for data collection or demonstration purposes.

  16. Embedding assessment in a simulation skills training program for medical and midwifery students: A pre- and post-intervention evaluation.

    PubMed

    Kumar, Arunaz; Nestel, Debra; East, Christine; Hay, Margaret; Lichtwark, Irene; McLelland, Gayle; Bentley, Deidre; Hall, Helen; Fernando, Shavi; Hobson, Sebastian; Larmour, Luke; Dekoninck, Philip; Wallace, Euan M

    2018-02-01

    Simulation-based programs are increasingly being used to teach obstetrics and gynaecology examinations, but it is difficult to establish student learning acquired through them. Assessment may test student learning but its role in learning itself is rarely recognised. We undertook this study to assess medical and midwifery student learning through a simulation program using a pre-test and post-test design and also to evaluate use of assessment as a method of learning. The interprofessional simulation education program consisted of a brief pre-reading document, a lecture, a video demonstration and a hands-on workshop. Over a 24-month period, 405 medical and 104 midwifery students participated in the study and were assessed before and after the program. Numerical data were analysed using paired t-test and one-way analysis of variance. Students' perceptions of the role of assessment in learning were qualitatively analysed. The post-test scores were significantly higher than the pre-test (P < 0.001) with improvements in scores in both medical and midwifery groups. Students described the benefit of assessment on learning in preparation of the assessment, reinforcement of learning occurring during assessment and reflection on performance cementing previous learning as a post-assessment effect. Both medical and midwifery students demonstrated a significant improvement in their test scores and for most students the examination process itself was a positive learning experience. © 2017 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  17. 75 FR 35977 - Significant New Use Rules on Certain Chemical Substances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-24

    ... demonstrated by testing to be impervious (Ansell NEOX style 9-912 gloves have been shown to satisfy this... orders. The Office of Management and Budget (OMB) has exempted these types of actions from review under...

  18. Multi-material Preforming of Structural Composites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Norris, Robert E.; Eberle, Cliff C.; Pastore, Christopher M.

    2015-05-01

    Fiber-reinforced composites offer significant weight reduction potential, with glass fiber composites already widely adopted. Carbon fiber composites deliver the greatest performance benefits, but their high cost has inhibited widespread adoption. This project demonstrates that hybrid carbon-glass solutions can realize most of the benefits of carbon fiber composites at much lower cost. ORNL and Owens Corning Reinforcements along with program participants at the ORISE collaborated to demonstrate methods for produce hybrid composites along with techniques to predict performance and economic tradeoffs. These predictions were then verified in testing coupons and more complex demonstration articles.

  19. Test Results for Entry Guidance Methods for Space Vehicles

    NASA Technical Reports Server (NTRS)

    Hanson, John M.; Jones, Robert E.

    2004-01-01

    There are a number of approaches to advanced guidance and control that have the potential for achieving the goals of significantly increasing reusable launch vehicle (or any space vehicle that enters an atmosphere) safety and reliability, and reducing the cost. This paper examines some approaches to entry guidance. An effort called Integration and Testing of Advanced Guidance and Control Technologies has recently completed a rigorous testing phase where these algorithms faced high-fidelity vehicle models and were required to perform a variety of representative tests. The algorithm developers spent substantial effort improving the algorithm performance in the testing. This paper lists the test cases used to demonstrate that the desired results are achieved, shows an automated test scoring method that greatly reduces the evaluation effort required, and displays results of the tests. Results show a significant improvement over previous guidance approaches. The two best-scoring algorithm approaches show roughly equivalent results and are ready to be applied to future vehicle concepts.

  20. Test Results for Entry Guidance Methods for Reusable Launch Vehicles

    NASA Technical Reports Server (NTRS)

    Hanson, John M.; Jones, Robert E.

    2003-01-01

    There are a number of approaches to advanced guidance and control (AG&C) that have the potential for achieving the goals of significantly increasing reusable launch vehicle (RLV) safety and reliability, and reducing the cost. This paper examines some approaches to entry guidance. An effort called Integration and Testing of Advanced Guidance and Control Technologies (ITAGCT) has recently completed a rigorous testing phase where these algorithms faced high-fidelity vehicle models and were required to perform a variety of representative tests. The algorithm developers spent substantial effort improving the algorithm performance in the testing. This paper lists the test cases used to demonstrate that the desired results are achieved, shows an automated test scoring method that greatly reduces the evaluation effort required, and displays results of the tests. Results show a significant improvement over previous guidance approaches. The two best-scoring algorithm approaches show roughly equivalent results and are ready to be applied to future reusable vehicle concepts.

  1. Density Deconvolution With EPI Splines

    DTIC Science & Technology

    2015-09-01

    effects of various substances on test subjects [11], [12]. Whereas in geophysics, a shot may be fired into the ground, in pharmacokinetics, a signal is...be significant, including medicine, bioinformatics, chemistry, as- tronomy, and econometrics , as well as an extensive review of kernel based methods...demonstrate the effectiveness of our model in simulations motivated by test instances in [32]. We consider an additive measurement model scenario where

  2. Reusable Launch Vehicle Technology Program

    NASA Technical Reports Server (NTRS)

    Freeman, Delma C., Jr.; Talay, Theodore A.; Austin, R. Eugene

    1996-01-01

    Industry/NASA Reusable Launch Vehicle (RLV) Technology Program efforts are underway to design, test, and develop technologies and concepts for viable commercial launch systems that also satisfy national needs at acceptable recurring costs. Significant progress has been made in understanding the technical challenges of fully reusable launch systems and the accompanying management and operational approaches for achieving a low-cost program. This paper reviews the current status of the Reusable Launch Vehicle Technology Program including the DC-XA, X-33 and X-34 flight systems and associated technology programs. It addresses the specific technologies being tested that address the technical and operability challenges of reusable launch systems including reusable cryogenic propellant tanks, composite structures, thermal protection systems, improved propulsion, and subsystem operability enhancements. The recently concluded DC-XA test program demonstrated some of these technologies in ground and flight tests. Contracts were awarded recently for both the X-33 and X-34 flight demonstrator systems. The Orbital Sciences Corporation X-34 flight test vehicle will demonstrate an air-launched reusable vehicle capable of flight to speeds of Mach 8. The Lockheed-Martin X-33 flight test vehicle will expand the test envelope for critical technologies to flight speeds of Mach 15. A propulsion program to test the X-33 linear aerospike rocket engine using a NASA SR-71 high speed aircraft as a test bed is also discussed. The paper also describes the management and operational approaches that address the challenge of new cost-effective, reusable launch vehicle systems.

  3. Sensitivity, Specificity, Predictive Values, and Accuracy of Three Diagnostic Tests to Predict Inferior Alveolar Nerve Blockade Failure in Symptomatic Irreversible Pulpitis

    PubMed Central

    Rodríguez-Wong, Laura; Noguera-González, Danny; Esparza-Villalpando, Vicente; Montero-Aguilar, Mauricio

    2017-01-01

    Introduction The inferior alveolar nerve block (IANB) is the most common anesthetic technique used on mandibular teeth during root canal treatment. Its success in the presence of preoperative inflammation is still controversial. The aim of this study was to evaluate the sensitivity, specificity, predictive values, and accuracy of three diagnostic tests used to predict IANB failure in symptomatic irreversible pulpitis (SIP). Methodology A cross-sectional study was carried out on the mandibular molars of 53 patients with SIP. All patients received a single cartridge of mepivacaine 2% with 1 : 100000 epinephrine using the IANB technique. Three diagnostic clinical tests were performed to detect anesthetic failure. Anesthetic failure was defined as a positive painful response to any of the three tests. Sensitivity, specificity, predictive values, accuracy, and ROC curves were calculated and compared and significant differences were analyzed. Results IANB failure was determined in 71.7% of the patients. The sensitivity scores for the three tests (lip numbness, the cold stimuli test, and responsiveness during endodontic access) were 0.03, 0.35, and 0.55, respectively, and the specificity score was determined as 1 for all of the tests. Clinically, none of the evaluated tests demonstrated a high enough accuracy (0.30, 0.53, and 0.68 for lip numbness, the cold stimuli test, and responsiveness during endodontic access, resp.). A comparison of the areas under the curve in the ROC analyses showed statistically significant differences between the three tests (p < 0.05). Conclusion None of the analyzed tests demonstrated a high enough accuracy to be considered a reliable diagnostic tool for the prediction of anesthetic failure. PMID:28694714

  4. Short-distance walking speed tests in people with Parkinson disease: reliability, responsiveness, and validity.

    PubMed

    Combs, Stephanie A; Diehl, M Dyer; Filip, Jacqueline; Long, Erin

    2014-02-01

    The aims of this study were to determine test-retest reliability and responsiveness of short-distance walking speed tests for persons with Parkinson disease (PD). Discriminant and convergent validity of walking speed tests were also examined. Eighty-eight participants with PD (mean age, 66 years) with mild to moderate severity (stages 1-4 on the Hoehn and Yahr Scale) were tested on medications. Measures of activity included the comfortable and fast 10-m walk tests (CWT, FWT), 6-min walk test (6MWT), mini balance evaluations systems test (mini-BEST Test), fear of falling (FoF), and the Activity-Specific Balance Confidence Scale (ABC). The mobility subsection of the PD quality of life-39 (PDQ39-M) served as a participation-based measure. Test-retest reliability was high for both walking speed measures (CWT, ICC(2,1) = 0.98; FWT, ICC(2,1) = 0.99). Minimal detectable change (MDC(95)) for the CWT and FWT was 0.09 m/s and 0.13 m/s respectively. Participants at Hoehn & Yahr levels 3/4 demonstrated significantly slower walking speed with the CWT and FWT than participants at Hoehn & Yahr levels 1 and 2 (P < .01). The CWT and FWT were both significantly (P ≤ .002) correlated with all activity and participation-based measures. Short-distance walking speed tests are clinically useful measures for persons with PD. The CWT and FWT are highly reliable and responsive to change in persons with PD. Short distance walking speed can be used to discriminate differences in gait function between persons with mild and moderate PD severity. The CWT and FWT had moderate to strong associations with other activity and participation based measures demonstrating convergent validity. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Enhancements to the FAST-MAC Circulation Control Model and Recent High-Reynolds Number Testing in the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Milholen, William E., II; Jones, Gregory S.; Chan, David T.; Goodliff, Scott L.; Anders, Scott G.; Melton, Latunia P.; Carter, Melissa B.; Allan, Brian G.; Capone, Francis J.

    2013-01-01

    A second wind tunnel test of the FAST-MAC circulation control model was recently completed in the National Transonic Facility at the NASA Langley Research Center. The model was equipped with four onboard flow control valves allowing independent control of the circulation control plenums, which were directed over a 15% chord simple-hinged flap. The model was configured for low-speed high-lift testing with flap deflections of 30 and 60 degrees, along with the transonic cruise configuration with zero degree flap deflection. Testing was again conducted over a wide range of Mach numbers up to 0.88, and Reynolds numbers up to 30 million based on the mean chord. The first wind tunnel test had poor transonic force and moment data repeatability at mild cryogenic conditions due to inadequate thermal conditioning of the balance. The second test demonstrated that an improvement to the balance heating system significantly improved the transonic data repeatability, but also indicated further improvements are still needed. The low-speed highlift performance of the model was improved by testing various blowing slot heights, and the circulation control was again demonstrated to be effective in re-attaching the flow over the wing at off-design transonic conditions. A new tailored spanwise blowing technique was also demonstrated to be effective at transonic conditions with the benefit of reduced mass flow requirements.

  6. The other half of the story: effect size analysis in quantitative research.

    PubMed

    Maher, Jessica Middlemis; Markey, Jonathan C; Ebert-May, Diane

    2013-01-01

    Statistical significance testing is the cornerstone of quantitative research, but studies that fail to report measures of effect size are potentially missing a robust part of the analysis. We provide a rationale for why effect size measures should be included in quantitative discipline-based education research. Examples from both biological and educational research demonstrate the utility of effect size for evaluating practical significance. We also provide details about some effect size indices that are paired with common statistical significance tests used in educational research and offer general suggestions for interpreting effect size measures. Finally, we discuss some inherent limitations of effect size measures and provide further recommendations about reporting confidence intervals.

  7. Field Evaluation of All-Season Tactical Engine Oil OE/HDO-15/40 at Ft. Knox, Kentucky and Ft. Bliss, Texas

    DTIC Science & Technology

    1986-07-01

    qualified lubricants were employed in the test, one product at each of the test locations. The test lubricants were used in all equipment components...Overall, the grade 15W-40 products demonstrated satisfactory and equivalent performance to single-graded oils. The oil was well received by both...operators and maintenance personnel who noted that the grade 15W-40 products significantly reduced logistics burden by having only one grade product to

  8. Fatigue Failure of Space Shuttle Main Engine Turbine Blades

    NASA Technical Reports Server (NTRS)

    Swanson, Gregrory R.; Arakere, Nagaraj K.

    2000-01-01

    Experimental validation of finite element modeling of single crystal turbine blades is presented. Experimental results from uniaxial high cycle fatigue (HCF) test specimens and full scale Space Shuttle Main Engine test firings with the High Pressure Fuel Turbopump Alternate Turbopump (HPFTP/AT) provide the data used for the validation. The conclusions show the significant contribution of the crystal orientation within the blade on the resulting life of the component, that the analysis can predict this variation, and that experimental testing demonstrates it.

  9. Using the NPSS Environment to Model an Altitude Test Facility

    NASA Technical Reports Server (NTRS)

    Lavelle, Thomas M.; Owen, Albert K.; Huffman, Brian C.

    2013-01-01

    An altitude test facility was modeled using Numerical Propulsion System Simulation (NPSS). This altitude test facility model represents the most detailed facility model developed in the NPSS architecture. The current paper demonstrates the use of the NPSS system to define the required operating range of a component for the facility. A significant number of additional component models were easily developed to complete the model. Discussed in this paper are the additional components developed and what was done in the development of these components.

  10. Evaluation of the Thermo Scientific SureTect Listeria monocytogenes Assay.

    PubMed

    Cloke, Jonathan; Leon-Velarde, Carlos; Larson, Nathan; Dave, Keron; Evans, Katharine; Crabtree, David; Hughes, Annette; Hopper, Craig; Simpson, Helen; Withey, Sophie; Oleksiuk, Milena; Holopainen, Jani; Wickstrand, Nina; Kauppinen, Mikko

    2014-01-01

    The Thermo Scientific SureTect Listeria monocytogenes Assay is a new real-time PCR assay for the detection of Listeria monocytogenes in food and environmental samples. This assay was validated using the AOAC Research Institute (AOAC-RI) Performance Tested Methods program in comparison to the reference method detailed in International Organization for Standardization 11290-1:1996, including Amendment 1:2004 with the following foods and food contact surfaces: smoked salmon, processed cheese, fresh bagged spinach, fresh cantaloupe, cooked prawns (chilled product), cooked sliced turkey meat (chilled product), ice cream, pork frankfurters, salami, ground raw beef meat (12% fat), plastic, and stainless steel. All matrixes were tested by Thermo Fisher Scientific, Microbiology Division, Basingstoke, UK. In addition, three matrixes (pork frankfurters, bagged lettuce, and stainless steel) were analyzed independently as part of the AOAC-RI controlled laboratory study by the University of Guelph, Canada. Using probability of detection (POD) statistical analysis, a significant difference was demonstrated between the candidate and reference methods for salami, cooked sliced turkey and ice cream in favor of the SureTect assay. For all other matrixes, no significant difference by POD was seen between the two methods during the study. Inclusivity and exclusivity testing was also conducted with 53 and 30 isolates, respectively, which demonstrated that the SureTect assay was able to detect all serotypes of L. monocytogenes. None of the exclusivity isolates analyzed were detected by the SureTect assay. Ruggedness testing was conducted to evaluate the performance of the assay with specific method deviations outside the recommended parameters open to variation, i.e., enrichment time and temperature and lysis temperature, which demonstrated that the assay gave reliable performance. Accelerated stability testing was also conducted, validating the assay shelf life.

  11. Experimental demonstration of radiation effects on the performance of a stirling-alternator convertor and candidate materials evaluation

    NASA Astrophysics Data System (ADS)

    Mireles, Omar R.

    Free-piston Stirling power convertors are under consideration by NASA for service in the Advanced Stirling Radioisotope Generator (ASRG) and Fission Surface Power (FSP) systems to enable aggressive exploration missions by providing a reliable and constant power supply. The ASRG must withstand environmental radiation conditions, while the FSP system must tolerate a mixed neutron and gamma-ray environment resulting from self-irradiation. Stirling-alternators utilize rare earth magnets and a variety of organic materials whose radiation limits dominate service life estimates and shielding requirements. The project objective was to demonstrate the performance of the alternator, identify materials that exhibit excessive radiation sensitivity, identify radiation tolerant substitutes, establish empirical dose limits, and demonstrate the feasibility of cost effective nuclear and radiation tests by selection of the appropriate personnel and test facilities as a function of hardware maturity. The Stirling Alternator Radiation Test Article (SARTA) was constructed from linear alternator components of a Stirling convertor and underwent significant pre-exposure characterization. The SARTA was operated at the Sandia National Laboratories Gamma Irradiation Facility to a dose of over 40 Mrad. Operating performance was within nominal variation, although modestly decreasing trends occurred in later runs as well as the detection of an electrical fault after the final exposure. Post-irradiation disassembly and internal inspection revealed minimal degradation of the majority of the organic components. Radiation testing of organic material coupons was conducted since the majority of the literature was inconsistent. These inconsistencies can be attributed to testing at environmental conditions vastly different than those Stirling-alternator organics will experience during operation. Samples were irradiated at the Texas A&M TRIGA reactor to above expected FSP neutron fluence. A thorough materials evaluation followed and results indicate that the majority of material properties experienced minimal statistically significant change.

  12. Design and Implementation of a Thermal Load Reduction System in a Hyundai PHEV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kreutzer, Cory J; Rugh, John P

    Increased market penetration of electric drive vehicles (EDVs) requires overcoming a number of hurdles including limited vehicle range and the elevated cost of EDVs as compared to conventional vehicles. Climate control loads have a significant impact on range, cutting it by over 50% in both cooling and heating conditions. In order to minimize the impact of climate control on EDV range, the National Renewable Energy Laboratory has partnered with Hyundai America and key industry partners to quantify the performance of thermal load reduction technologies on a Hyundai Sonata PHEV. Technologies that impact vehicle cabin heating in cold weather conditions andmore » cabin cooling in warm weather conditions were evaluated. Tests included thermal transient and steady-state periods for all technologies, including the development of a new test methodology to evaluate the performance of occupant thermal conditioning. Heated surfaces and increased insulation demonstrated significant reductions in energy use from steady-state heating, including a 29% - 59% reduction from heated surfaces. Solar control glass packages demonstrated significant reductions in energy use for both transient and steady-state cooling, with up to a 42% reduction in transient and 12.8% reduction in steady-state energy use for the packages evaluated. Technologies that demonstrated significant climate control load reduction were selected for incorporation into a complete thermal load reduction package. The complete package is set to be evaluated in the second phase of the ongoing project.« less

  13. A Robust Method of Measuring Other-Race and Other-Ethnicity Effects: The Cambridge Face Memory Test Format

    PubMed Central

    McKone, Elinor; Stokes, Sacha; Liu, Jia; Cohan, Sarah; Fiorentini, Chiara; Pidcock, Madeleine; Yovel, Galit; Broughton, Mary; Pelleg, Michel

    2012-01-01

    Other-race and other-ethnicity effects on face memory have remained a topic of consistent research interest over several decades, across fields including face perception, social psychology, and forensic psychology (eyewitness testimony). Here we demonstrate that the Cambridge Face Memory Test format provides a robust method for measuring these effects. Testing the Cambridge Face Memory Test original version (CFMT-original; European-ancestry faces from Boston USA) and a new Cambridge Face Memory Test Chinese (CFMT-Chinese), with European and Asian observers, we report a race-of-face by race-of-observer interaction that was highly significant despite modest sample size and despite observers who had quite high exposure to the other race. We attribute this to high statistical power arising from the very high internal reliability of the tasks. This power also allows us to demonstrate a much smaller within-race other ethnicity effect, based on differences in European physiognomy between Boston faces/observers and Australian faces/observers (using the CFMT-Australian). PMID:23118912

  14. Flight Test Comparison of Different Adaptive Augmentations for Fault Tolerant Control Laws for a Modified F-15 Aircraft

    NASA Technical Reports Server (NTRS)

    Burken, John J.; Hanson, Curtis E.; Lee, James A.; Kaneshige, John T.

    2009-01-01

    This report describes the improvements and enhancements to a neural network based approach for directly adapting to aerodynamic changes resulting from damage or failures. This research is a follow-on effort to flight tests performed on the NASA F-15 aircraft as part of the Intelligent Flight Control System research effort. Previous flight test results demonstrated the potential for performance improvement under destabilizing damage conditions. Little or no improvement was provided under simulated control surface failures, however, and the adaptive system was prone to pilot-induced oscillations. An improved controller was designed to reduce the occurrence of pilot-induced oscillations and increase robustness to failures in general. This report presents an analysis of the neural networks used in the previous flight test, the improved adaptive controller, and the baseline case with no adaptation. Flight test results demonstrate significant improvement in performance by using the new adaptive controller compared with the previous adaptive system and the baseline system for control surface failures.

  15. Testing Measurement Invariance across Groups of Children with and without Attention-Deficit/ Hyperactivity Disorder: Applications for Word Recognition and Spelling Tasks

    PubMed Central

    Lúcio, Patrícia S.; Salum, Giovanni; Swardfager, Walter; Mari, Jair de Jesus; Pan, Pedro M.; Bressan, Rodrigo A.; Gadelha, Ary; Rohde, Luis A.; Cogo-Moreira, Hugo

    2017-01-01

    Although studies have consistently demonstrated that children with attention-deficit/hyperactivity disorder (ADHD) perform significantly lower than controls on word recognition and spelling tests, such studies rely on the assumption that those groups are comparable in these measures. This study investigates comparability of word recognition and spelling tests based on diagnostic status for ADHD through measurement invariance methods. The participants (n = 1,935; 47% female; 11% ADHD) were children aged 6–15 with normal IQ (≥70). Measurement invariance was investigated through Confirmatory Factor Analysis and Multiple Indicators Multiple Causes models. Measurement invariance was attested in both methods, demonstrating the direct comparability of the groups. Children with ADHD were 0.51 SD lower in word recognition and 0.33 SD lower in spelling tests than controls. Results suggest that differences in performance on word recognition and spelling tests are related to true mean differences based on ADHD diagnostic status. Implications for clinical practice and research are discussed. PMID:29118733

  16. Testing Measurement Invariance across Groups of Children with and without Attention-Deficit/ Hyperactivity Disorder: Applications for Word Recognition and Spelling Tasks.

    PubMed

    Lúcio, Patrícia S; Salum, Giovanni; Swardfager, Walter; Mari, Jair de Jesus; Pan, Pedro M; Bressan, Rodrigo A; Gadelha, Ary; Rohde, Luis A; Cogo-Moreira, Hugo

    2017-01-01

    Although studies have consistently demonstrated that children with attention-deficit/hyperactivity disorder (ADHD) perform significantly lower than controls on word recognition and spelling tests, such studies rely on the assumption that those groups are comparable in these measures. This study investigates comparability of word recognition and spelling tests based on diagnostic status for ADHD through measurement invariance methods. The participants ( n = 1,935; 47% female; 11% ADHD) were children aged 6-15 with normal IQ (≥70). Measurement invariance was investigated through Confirmatory Factor Analysis and Multiple Indicators Multiple Causes models. Measurement invariance was attested in both methods, demonstrating the direct comparability of the groups. Children with ADHD were 0.51 SD lower in word recognition and 0.33 SD lower in spelling tests than controls. Results suggest that differences in performance on word recognition and spelling tests are related to true mean differences based on ADHD diagnostic status. Implications for clinical practice and research are discussed.

  17. Design and Fabrication of a Stirling Thermal Vacuum Test

    NASA Technical Reports Server (NTRS)

    Oriti, Salvatore M.; Schreiber, Jeffrey G.

    2004-01-01

    A Stirling Radioisotope Generator (SRG110) is being developed for potential use on future NASA space science missions. The development effort is being conducted by Lockheed Martin under contract to the Department of Energy (DOE). The Stirling Technology Company supplies the free-piston Stirling power convertors, and NASA Glenn Research Center (GRC) provides support to the effort in a range of technologies. This generator features higher efficiency and specific power compared to the currently used alternatives. One potential application for the generator would entail significant cruise time in the vacuum of deep space. A test has been conceived at GRC to demonstrate functionality of the Stirling convertors in a thermal vacuum environment. The test article resembles the configuration of the SRG, however the requirement for low mass was not considered. This test will demonstrate the operation of the Stirling convertors in the thermal vacuum environment, simulating deep space, over an extended period of operation. The analysis, design, and fabrication of the test article will be described in this paper.

  18. Certain performance values arising from mammographic test set readings correlate well with clinical audit.

    PubMed

    Soh, BaoLin Pauline; Lee, Warwick Bruce; Mello-Thoms, Claudia; Tapia, Kriscia; Ryan, John; Hung, Wai Tak; Thompson, Graham; Heard, Rob; Brennan, Patrick

    2015-08-01

    Test sets have been increasingly utilised to augment clinical audit in breast screening programmes; however, their relationship has never been satisfactorily understood. This study examined the relationship between mammographic test set performance and clinical audit data. Clinical audit data over a 2-year period was generated for each of 20 radiologists. Sixty mammographic examinations, consisting of 40 normal and 20 cancer cases, formed the test set. Readers located any identifiable cancer, and levels of confidence were scored from 2 to 5, where a score of 3 and above is considered a recall rating. Jackknifing free response operating characteristic (JAFROC) figure-of-merit (FOM), location sensitivity and specificity were calculated for individual readers and then compared with clinical audit values using Spearman's rho. JAFROC FOM showed significant correlations to: recall rate at a first round of screening (r = 0.51; P = 0.02); rate of small invasive cancers per 10 000 reads (r = 0.5; P = 0.02); percentage of all cancers read that were not recalled (r = -0.51; P = 0.02); and sensitivity (r = 0.51; P = 0.02). Location sensitivity demonstrated significant correlations with: rate of small invasive cancers per 10 000 reads (r = 0.46; P = 0.04); rate of DCIS (ductal carcinoma in situ) per 10 000 reads (r = 0.44; P = 0.05); detection rate of all invasive cancers and DCIS per 10 000 reads (r = 0.54; P = 0.01); percentage of all cancers read that were not recalled (r = -0.57; P = 0.009); and sensitivity (r = 0.57; P = 0.009). No other significant relationships were noted. Performance indicators from test set demonstrate significant correlations with specific aspects of clinical performance, although caution needs to be exercised when generalising test set specificity to the clinical situation. © 2015 The Royal Australian and New Zealand College of Radiologists.

  19. A Germline Variant on Chromosome 4q31.1 Associates with Susceptibility to Developing Colon Cancer Metastasis

    PubMed Central

    Schmit, Stephanie L.; Stadler, Zsofia K.; Joseph, Vijai; Zhang, Lu; Willis, Joseph E.; Scacheri, Peter; Veigl, Martina; Adams, Mark D.; Raskin, Leon; Sullivan, John F.; Stratton, Kelly; Shia, Jinru; Ellis, Nathan; Rennert, Hedy S.; Manschreck, Christopher; Li, Li; Offit, Kenneth; Elston, Robert C.; Rennert, Gadi; Gruber, Stephen B.

    2016-01-01

    We tested for germline variants showing association to colon cancer metastasis using a genome-wide association study that compared Ashkenazi Jewish individuals with stage IV metastatic colon cancers versus those with stage I or II non-metastatic colon cancers. In a two-stage study design, we demonstrated significant association to developing metastatic disease for rs60745952, that in Ashkenazi discovery and validation cohorts, respectively, showed an odds ratio (OR) = 2.3 (P = 2.73E-06) and OR = 1.89 (P = 8.05E-04) (exceeding validation threshold of 0.0044). Significant association to metastatic colon cancer was further confirmed by a meta-analysis of rs60745952 in these datasets plus an additional Ashkenazi validation cohort (OR = 1.92; 95% CI: 1.28–2.87), and by a permutation test that demonstrated a significantly longer haplotype surrounding rs60745952 in the stage IV samples. rs60745952, located in an intergenic region on chromosome 4q31.1, and not previously associated with cancer, is, thus, a germline genetic marker for susceptibility to developing colon cancer metastases among Ashkenazi Jews. PMID:26751797

  20. The feasibility of utilizing remotely sensed data to assess and monitor oceanic gamefish

    NASA Technical Reports Server (NTRS)

    Savastano, K. J.; Leming, T. D.

    1975-01-01

    An investigation was conducted to establish the feasibility of utilizing remotely sensed data acquired from aircraft and satellite platforms to provide information concerning the distribution and abundance of oceanic gamefish. The data from the test area was jointly acquired by NASA, the Navy, the Air Force and NOAA/NMFS elements and private and professional fishermen in the northeastern Gulf of Mexico. The data collected has made it possible to identify fisheries significant environmental parameters for white marlin. Prediction models, based on catch data and surface truth information, were developed and demonstrated a potential for significantly reducing search by identifying areas that have a high probability of productivity. Three of the parameters utilized by the models, chlorophyll-a, sea surface temperature, and turbidity were inferred from aircraft sensor data and were tested. Effective use of Skylab data was inhibited by cloud cover and delayed delivery. Initial efforts toward establishing the feasibility of utilizing remotely sensed data to assess and monitor the distribution of oceanic gamefish has successfully identified fisheries significant oceanographic parameters and demonstrated the capability of remotely measuring most of the parameters.

  1. Biofilm formation, cellulose production, and curli biosynthesis by Salmonella originating from produce, animal, and clinical sources.

    PubMed

    Solomon, Ethan B; Niemira, Brendan A; Sapers, Gerald M; Annous, Bassam A

    2005-05-01

    The ability of 71 strains of Salmonella enterica originating from produce, meat, or clinical sources to form biofilms was investigated. A crystal violet binding assay demonstrated no significant differences in biofilm formation by isolates from any source when tested in any of the following three media: Luria-Bertani broth supplemented with 2% glucose, tryptic soy broth (TSB), or 1/20th-strength TSB. Incubation was overnight at 30 degrees C under static conditions. Curli production and cellulose production were monitored by assessing morphotypes on Luria-Bertani agar without salt containing Congo red and by assessing fluorescence on Luria-Bertani agar containing calcofluor, respectively. One hundred percent of the clinical isolates exhibited curli biosynthesis, and 73% demonstrated cellulose production. All meat-related isolates formed curli, and 84% produced cellulose. A total of 80% of produce-related isolates produced curli, but only 52% produced cellulose. Crystal violet binding was not statistically different between isolates representing the three morphotypes when grown in TSB; however, significant differences were observed when strains were cultured in the two other media tested. These data demonstrate that the ability to form biofilms is not dependent on the source of the test isolate and suggest a relationship between crystal violet binding and morphotype, with curli- and cellulose-deficient isolates being least effective in biofilm formation.

  2. Corneal Confocal Microscopy Detects Early Nerve Regeneration in Diabetic Neuropathy After Simultaneous Pancreas and Kidney Transplantation

    PubMed Central

    Tavakoli, Mitra; Mitu-Pretorian, Maria; Petropoulos, Ioannis N.; Fadavi, Hassan; Asghar, Omar; Alam, Uazman; Ponirakis, Georgios; Jeziorska, Maria; Marshall, Andy; Efron, Nathan; Boulton, Andrew J.; Augustine, Titus; Malik, Rayaz A.

    2013-01-01

    Diabetic neuropathy is associated with increased morbidity and mortality. To date, limited data in subjects with impaired glucose tolerance and diabetes demonstrate nerve fiber repair after intervention. This may reflect a lack of efficacy of the interventions but may also reflect difficulty of the tests currently deployed to adequately assess nerve fiber repair, particularly in short-term studies. Corneal confocal microscopy (CCM) represents a novel noninvasive means to quantify nerve fiber damage and repair. Fifteen type 1 diabetic patients undergoing simultaneous pancreas–kidney transplantation (SPK) underwent detailed assessment of neurologic deficits, quantitative sensory testing (QST), electrophysiology, skin biopsy, corneal sensitivity, and CCM at baseline and at 6 and 12 months after successful SPK. At baseline, diabetic patients had a significant neuropathy compared with control subjects. After successful SPK there was no significant change in neurologic impairment, neurophysiology, QST, corneal sensitivity, and intraepidermal nerve fiber density (IENFD). However, CCM demonstrated significant improvements in corneal nerve fiber density, branch density, and length at 12 months. Normalization of glycemia after SPK shows no significant improvement in neuropathy assessed by the neurologic deficits, QST, electrophysiology, and IENFD. However, CCM shows a significant improvement in nerve morphology, providing a novel noninvasive means to establish early nerve repair that is missed by currently advocated assessment techniques. PMID:23002037

  3. Genotoxic, Cytotoxic, Antigenotoxic, and Anticytotoxic Effects of Sulfonamide Chalcone Using the Ames Test and the Mouse Bone Marrow Micronucleus Test

    PubMed Central

    Borges, Flávio Fernandes Veloso; Bernardes, Aline; Perez, Caridad Noda; Silva, Daniela de Melo e

    2015-01-01

    Chalcones present several biological activities and sulfonamide chalcone derivatives have shown important biological applications, including antitumor activity. In this study, genotoxic, cytotoxic, antigenotoxic, and anticytotoxic activities of the sulfonamide chalcone N-{4-[3-(4-nitrophenyl)prop-2-enoyl]phenyl} benzenesulfonamide (CPN) were assessed using the Salmonella typhimurium reverse mutation test (Ames test) and the mouse bone marrow micronucleus test. The results showed that CPN caused a small increase in the number of histidine revertant colonies in S. typhimurium strains TA98 and TA100, but not statistically significant (p > 0.05). The antimutagenicity test showed that CPN significantly decreased the number of His+ revertants in strain TA98 at all doses tested (p < 0.05), whereas in strain TA100 this occurred only at doses higher than 50 μg/plate (p < 0.05). The results of the micronucleus test indicated that CPN significantly increased the frequency of micronucleated polychromatic erythrocytes (MNPCE) at 24 h and 48 h, revealing a genotoxic effect of this compound. Also, a significant decrease in polychromatic/normochromatic erythrocyte ratio (PCE/NCE) was observed at the higher doses of CPN at 24 h and 48 h (p < 0.05), indicating its cytotoxic action. CPN co-administered with mitomycin C (MMC) significantly decreased the frequency of MNPCE at almost all doses tested at 24 h (p < 0.05), showing its antigenotoxic activity, and also presented a small decrease in MNPCE at 48 h (p > 0.05). Additionally, CPN co-administered with MMC significantly increased PCE/NCE ratio at all doses tested, demonstrating its anticytotoxic effect. In summary, CPN presented genotoxic, cytotoxic, antigenotoxic, and anticytotoxic properties. PMID:26335560

  4. An Exploratory Application of Neural Networks to the Sortie Generation Forecasting Problem

    DTIC Science & Technology

    1991-09-01

    modifiable--a configuration clearly inspired by neurophysiology . Rosenblatt and others effectively demonstrated that in using such an architectural...different perspectives (i.e., longitudinally and cross-sectionally), significance testing between prediction results may promote more enlightened network

  5. A rule-based software test data generator

    NASA Technical Reports Server (NTRS)

    Deason, William H.; Brown, David B.; Chang, Kai-Hsiung; Cross, James H., II

    1991-01-01

    Rule-based software test data generation is proposed as an alternative to either path/predicate analysis or random data generation. A prototype rule-based test data generator for Ada programs is constructed and compared to a random test data generator. Four Ada procedures are used in the comparison. Approximately 2000 rule-based test cases and 100,000 randomly generated test cases are automatically generated and executed. The success of the two methods is compared using standard coverage metrics. Simple statistical tests showing that even the primitive rule-based test data generation prototype is significantly better than random data generation are performed. This result demonstrates that rule-based test data generation is feasible and shows great promise in assisting test engineers, especially when the rule base is developed further.

  6. Effects of angle of model-demonstration on learning of motor skill.

    PubMed

    Ishikura, T; Inomata, K

    1995-04-01

    The purpose was to examine the effects of three different demonstrations by a model on acquisition and retention of a sequential gross movement task. The second purpose was to examine the relationship between reversal processing of visual information about skills and coding of skill information. Thirty undergraduates (15 men and 15 women) were assigned into one of three conditions, Objective condition which demonstrated the task with the model facing the subject. Looking-glass condition in which the skill was demonstrated with the model facing the subject who viewed the performance opposite the right and left directions in executing the task, and the Subjective condition in which the subject observed the model from the rear. Number of immediate recall tests required to accomplish the sequential movements completely and the sum of the performance points for reproduced movements at each delayed recall test (1 day, 7 days, and 5 mo. after the immediate recall test) were employed. Analysis indicated the Subjective condition produced a significantly greater modeling effect in immediate recall of the movements than the Looking-glass condition. Retention of the acquired skills was almost equal under the three conditions.

  7. Correlation of clinical examination characteristics with three sources of chronic low back pain.

    PubMed

    Young, Sharon; Aprill, Charles; Laslett, Mark

    2003-01-01

    Research has demonstrated some progress in using a clinical examination to predict discogenic or sacroiliac (SI) joint sources of pain. No clear predictors of symptomatic lumbar zygapophysial joints have yet been demonstrated. To identify significant components of a clinical examination that are associated with symptomatic lumbar discs, zygapophysial joints and SI joints. A prospective, criterion-related concurrent validity study performed at a private radiology practice specializing in spinal diagnostics. The sample consisted of 81 patients with chronic lumbopelvic pain referred for diagnostic injections. Contingency tables were constructed for nine features of the clinical evaluation compared with the results of diagnostic injections. Statistical analysis included chi-squared test for independence, phi and odds ratios with confidence intervals. Patients received blinded clinical examinations by physical therapists, and diagnostic injections were used as the criterion standard. Significant relationships were found between discogenic pain and centralization of pain during repeated movement testing, and pain when rising from sitting. Lumbar zygapophysial joint pain was associated with absence of pain when rising from sitting. Sacroiliac joint pain was related to three or more positive pain provocation tests, pain when rising from sitting, unilateral pain and absence of lumbar pain. Significant correlations exist between clinical examination findings and symptomatic lumbar discs, zygapophysial and SI joints. The strongest relationships were seen between SI joint pain and three or more positive pain provocation tests, centralization of pain for symptomatic discs and absence of pain when rising from sitting for symptomatic lumbar zygapophysial joints.

  8. In vitro cytotoxicity of maxillofacial silicone elastomers: effect of accelerated aging.

    PubMed

    Bal, Bilge Turhan; Yilmaz, Handan; Aydin, Cemal; Karakoca, Seçil; Yilmaz, Sükran

    2009-04-01

    The purpose of this in vitro study was to evaluate the cytotoxicity of three maxillofacial silicone elastomers at 24, 48, and 72 h on L-929 cells and to determine the effect of accelerated aging on the cytotoxicity of these silicone elastomers. Disc-shaped test samples of maxillofacial silicone elastomers (Cosmesil, Episil, Multisil) were fabricated according to manufacturers' instructions under aseptic conditions. Samples were then divided into three groups: (1) not aged; (2) aged for 150 h with an accelerated weathering tester; and (3) aged for 300 h. Then the samples were placed in Dulbecco's Modified Eagle Medium/Ham's F12 (DMEM/F12) for 24, 48, and 72 h. After the incubation periods, cytotoxicity of the extracts to cultured fibroblasts (L-929) was measured by MTT assay. The degree of cytotoxicity of each sample was determined according to the reference value represented by the cells with a control (culture without sample). Statistical significance was determined by repeated measurement ANOVA (p < 0.01) followed by Duncan's test (p < 0.05). All test materials in each group demonstrated high survival rates in MTT assay (Episil; 93.84%, Multisil; 88.30%, Cosmesil; 87.50%, respectively); however, in all groups, Episil material demonstrated significantly higher cell survival rate after each of the experimental incubation periods (p < 0.05). Accelerated aging for 150 and 300 h had no significant effect on the biocompatibility of maxillofacial silicone elastomers tested (p > 0.05).

  9. Cytotoxic effects of resin-modified orthodontic band adhesives. Are they safe?

    PubMed

    Malkoc, Siddik; Corekci, Bayram; Botsali, Hayriye Esra; Yalçin, Muhammet; Sengun, Abdülkadir

    2010-09-01

    To evaluate the cytotoxic effects of three different resin-modified orthodontic band adhesives. Three resin-modified orthodontic band adhesives (Bisco Ortho Band Paste LC, Multi-Cure Glass Ionomer Band Cement, and Transbond Plus Light Cure Band Adhesive) were prepared and the samples were extracted in 3 mL of Basal Medium Eagle with 10% newborn calf serum for 24 hours. The L929 cells were plated (25,000 cells/mL) in wells of 96-well dishes and maintained in a humidified incubator for 24 hours at 37 degrees C, 5% CO(2), and 95% air. After 24-hour incubation of the cells, the incubation medium was replaced by the immersed medium in which the samples were stored. Then L929 cells were incubated in contact with eluates for 24 hours. The cell mitochondrial activity was evaluated by the methyltetrazolium test. Twelve wells were used for each specimen, and methyltetrazolium tests were applied two times. The data were statistically analyzed using one-way analysis of variance and Tukey Honestly Significantly Different tests. Results with L929 fibroblasts demonstrated that all freshly prepared resin-modified orthodontic band adhesive materials reduced vital cell numbers (P > .05), in comparison to the control group. Our data demonstrate that all materials showed significant cytotoxicity compared to the control group. The results indicate that all materials showed significant cytotoxicity compared to the control group, and further studies using different test methods are needed for all resin-modified orthodontic band adhesives.

  10. Increasing the Efficiency on Producing Radiology Reports for Breast Cancer Diagnosis by Means of Structured Reports. A Comparative Study.

    PubMed

    Segrelles, J Damian; Medina, Rosana; Blanquer, Ignacio; Martí-Bonmatí, Luis

    2017-05-18

    Radiology reports are commonly written on free-text using voice recognition devices. Structured reports (SR) have a high potential but they are usually considered more difficult to fill-in so their adoption in clinical practice leads to a lower efficiency. However, some studies have demonstrated that in some cases, producing SRs may require shorter time than plain-text ones. This work focuses on the definition and demonstration of a methodology to evaluate the productivity of software tools for producing radiology reports. A set of SRs for breast cancer diagnosis based on BI-RADS have been developed using this method. An analysis of their efficiency with respect to free-text reports has been performed. The methodology proposed compares the Elapsed Time (ET) on a set of radiological reports. Free-text reports are produced with the speech recognition devices used in the clinical practice. Structured reports are generated using a web application generated with TRENCADIS framework. A team of six radiologists with three different levels of experience in the breast cancer diagnosis was recruited. These radiologists performed the evaluation, each one introducing 50 reports for mammography, 50 for ultrasound scan and 50 for MRI using both approaches. Also, the Relative Efficiency (REF) was computed for each report, dividing the ET of both methods. We applied the T-Student (T-S) test to compare the ETs and the ANOVA test to compare the REFs. Both tests were computed using the SPSS software. The study produced three DICOM-SR templates for Breast Cancer Diagnosis on mammography, ultrasound and MRI, using RADLEX terms based on BIRADs 5th edition. The T-S test on radiologists with high or intermediate profile, showed that the difference between the ET was only statistically significant for mammography and ultrasound. The ANOVA test performed grouping the REF by modalities, indicated that there were no significant differences between mammograms and ultrasound scans, but both have significant statistical differences with MRI. The ANOVA test of the REF for each modality, indicated that there were only significant differences in Mammography (ANOVA p = 0.024) and Ultrasound (ANOVA p = 0.008). The ANOVA test for each radiologist profile, indicated that there were significant differences on the high profile (ANOVA p = 0.028) and medium (ANOVA p = 0.045). In this work, we have defined and demonstrated a methodology to evaluate the productivity of software tools for producing radiology reports in Breast Cancer. We have evaluated that adopting Structured Reporting in mammography and ultrasound studies in breast cancer diagnosis improves the performance in producing reports.

  11. Influence of dietary supplementation with Lactobacillus reuteri on the oral flora of healthy subjects.

    PubMed

    Sinkiewicz, Gabriela; Cronholm, Sofie; Ljunggren, Lennart; Dahlén, Gunnar; Bratthall, Gunilla

    2010-01-01

    Investigate the presence of Lactobacillus reuteri in saliva after supplementation with L. reuteri and the probiotic effect of L. reuteri on plaque index and supra- and subgingival microbiota. The study included 23 healthy individuals, randomised into test or control subjects. At baseline and after 12 weeks saliva samples, plaque index and supra- and subgingival plaque samples were obtained. The test subjects were given the study product (containing L. reuteri, ATCC 55730 and ATCC PTA 5289) and the control subjects placebo for 12 weeks. Microbiological analyses were done by checkerboard DNA-DNA hybridization technique and selective culturing for lactobacilli determination. A significant increase in total Lactobacillus counts in saliva occurred in both groups (p < 0.05) with a significant increase of L. reuteri (p = 0.008) in the test group.Termination of intervention resulted in a wash out of L. reuteri. The control group demonstrated a statistically significant increase in PII after 12 weeks (p = 0.023) whilst there was no significant change in the test group. A significant increase was found for most bacterial species in both groups in supra- and subgingival plaque with no significant difference for any of the species between the groups. The ratio between "bad/good" supragingival bacteria decreased for the test group but this decrease did not reach significance. The corresponding ratio for subgingival bacteria decreased significantly in both groups. Supplementation of L. reuteri resulted in presence of L. reuteri in saliva but L. reuteri was washed out after termination of intervention. No significant effect on supra- or subgingival microbiota was observed. The significant increase in PII in the control group with no significant change in the test group may, however, indicate a probiotic effect of L. reuteri in this study population.

  12. Testing of neuroendocrine function in astronauts as related to fluid shifts

    NASA Astrophysics Data System (ADS)

    Sauseng-Fellegger, G.; König, E. M.; Hinghofer-Szalkay, H.; Jezová, D.; Vigas, M.

    We addressed the question of optimal conditions for neuroendocrine and cardiovascular testing in astronauts. We tested stress reactions during LBNP of ≤-50 mm Hg. There was a mild transient elevation of plasma GH concentration and a nonsignificant rise of plasma ACTH, while PRL, insulin and glucose remained unchanged. Aldosterone was decreased 5 and 10 min after beginning of LBNP, thereafter rose significantly, and displayed a further significant concentration increase 5 min post-LBNP. The endocrine and cardiovascular responses to submaximal exercise were tested at 8.00 am and 8.00 pm. Exercise-induced changes of heart rate and blood pressure remained unchanged with daytime whereas plasma concentrations of epinephrine, GH and PRL in response to work load were significantly higher in the evening than in the morning. As expected, basal resting values of plasma cortisol were significantly lower in the evening than in the morning but were similar one hour after cessation of exercise. Our findings demonstrate the importance of frequent sampling in case of transient physiological phenomena, and contribute to existing knowledge on circadian influences upon neuroendocrine stress responses.

  13. Innominate movement patterns, rotation trends and range of motion in individuals with low back pain of sacroiliac joint origin.

    PubMed

    Adhia, Divya Bharatkumar; Milosavljevic, Stephan; Tumilty, Steve; Bussey, Melanie D

    2016-02-01

    Innominate kinematic anomalies resulting in low back pain (LBP) of sacroiliac joint (SIJ) origin (SIJ-positive), has always been a topic of contention, owing to difficultly in its evaluation. Recent technique of electromagnetic palpation-digitization has been able to accurately quantify innominate kinematics in healthy individuals. The purpose of this study is to determine if participants with LBP of SIJ origin (SIJ-positive) demonstrate significantly different innominate kinematics than participants with LBP of non-SIJ origin (SIJ-negative). Single-blinded cross-sectional case-control study. Participants [n(122)] between the ages of 18 to 50 years, suffering from chronic non-specific LBP (≥3 months) volunteered in the study. An experienced musculoskeletal physiotherapist evaluated and classified participants into either SIJ-positive [n(45)] or SIJ-negative [n(77)] group, using the reference standard pain provocation tests [≥3 positive tests = SIJ-positive]. A research physiotherapist, blinded to clinical groups, conducted the innominate kinematic testing using a valid and reliable electromagnetic palpation-digitization technique, during prone lying incremental hip abduction-external rotation test positions. The results of the mixed model regression analyses demonstrated that SIJ-positive participants exhibited significantly different innominate movement patterns and trends of rotation, but not innominate ranges of motion, when compared with SIJ-negative LBP participants. These findings demonstrate association between SIJ pain and altered innominate kinematics, and have led the groundwork for further exploration of clinical measurement, relevance, and management of these potentially important movement observations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Cognitive Stimulation of Elderly Residents in Social Protection Centers in Cartagena, 2014.

    PubMed

    Melguizo Herrera, Estela; Bertel De La Hoz, Anyel; Paternina Osorio, Diego; Felfle Fuentes, Yurani; Porto Osorio, Leidy

    To determine the effectiveness of a program of cognitive stimulation of the elderly residents in Social Protection Centers in Cartagena, 2014. Quasi-experimental study with pre and post tests in control and experimental groups. A sample of 37 elderly residents in Social Protection Centers participated: 23 in the experimental group and 14 in the control group. A survey and a mental evaluation test (Pfeiffer) were applied. The experimental group participated in 10 sessions of cognitive stimulation. The paired t-test showed statistically significant differences in the Pfeiffer test, pre and post intervention, compared to the experimental group (P=.0005). The unpaired t-test showed statistically significant differences in Pfeiffer test results to the experimental and control groups (P=.0450). The analysis of the main components showed that more interrelated variables were: age, diseases, number of errors and test results; which were grouped around the disease variable, with a negative association. The intervention demonstrated a statistically significant improvement in cognitive functionality of the elderly. Nursing can lead this type of intervention. It should be studied further to strengthen and clarify these results. Copyright © 2016 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  15. A quantitative comparative analysis of Advancement via Independent Determination (AVID) in Texas middle schools

    NASA Astrophysics Data System (ADS)

    Reed, Krystal Astra

    The "Advancement via Individual Determination (AVID) program was designed to provide resources and strategies that enable underrepresented minority students to attend 4-year colleges" (AVID Center, 2013, p. 2). These students are characterized as the forgotten middle in that they have high test scores, average-to-low grades, minority or low socioeconomic status, and will be first-generation college students (AVID, 2011). Research indicates (Huerta, Watt, & Butcher, 2013) that strict adherence to 11 program components supports success of students enrolled in AVID, and AVID certification depends on districts following those components. Several studies (AVID Center, 2013) have investigated claims about the AVID program through qualitative analyses; however, very few have addressed this program quantitatively. This researcher sought to determine whether differences existed between student achievement and attendance rates between AVID and non-AVID middle schools. To achieve this goal, the researcher compared eighth-grade science and seventh- and eighth-grade mathematics scores from the 2007 to 2011 Texas Assessment of Knowledge and Skills (TAKS) and overall attendance rates in demographically equivalent AVID and non-AVID middle schools. Academic Excellence Indicator System (AEIS) reports from the Texas Education Agency (TEA) were used to obtain 2007 to 2011 TAKS results and attendance information for the selected schools. The results indicated a statistically significant difference between AVID demonstration students and non-AVID students in schools with similar CI. No statistically significant differences were found on any component of the TAKS for AVID economically disadvantaged students. The mean scores indicated an achievement gap between non-AVID and AVID demonstration middle schools. The findings from the other three research questions indicated no statistically significant differences between AVID and non-AVID student passing rates on the seventh- and eighth-grade TAKS math tests or on overall attendance rates. The mean scores on the eighth-grade TAKS science test revealed some positive results in the academic performance of economically disadvantaged in non-AVID demonstration middle schools. Specifically, the results indicated that the mean passing percentage of AVID demonstration was lower than that of non-AVID middle schools. The TAKS scores showed a small achievement gap between non-AVID and AVID demonstration middle schools.

  16. Reliability and Validity of the Behavioral Addiction Measure for Video Gaming.

    PubMed

    Sanders, James L; Williams, Robert J

    2016-01-01

    Most tests of video game addiction have weak construct validity and limited ability to correctly identify people in denial. The purpose of the present research was to investigate the reliability and validity of a new test of video game addiction (Behavioral Addiction Measure-Video Gaming [BAM-VG]) that was developed in part to address these deficiencies. Regular adult video gamers (n = 506) were recruited from a Canadian online panel and completed a survey containing three measures of excessive video gaming (BAM-VG; DSM-5 criteria for Internet Gaming Disorder [IGD]; and the IGD-20), as well as questions concerning extensiveness of video game involvement and self-report of problems associated with video gaming. One month later, they were reassessed for the purposes of establishing test-retest reliability. The BAM-VG demonstrated good internal consistency as well as 1 month test-retest reliability. Criterion-related validity was demonstrated by significant correlations with the following: time spent playing, self-identification of video game problems, and scores on other instruments designed to assess video game addiction (DSM-5 IGD, IGD-20). Consistent with the theory, principal component analysis identified two components underlying the BAM-VG that roughly correspond with impaired control and significant negative consequences deriving from this impaired control. Together with its excellent construct validity and other technical features, the BAM-VG represents a reliable and valid test of video game addiction.

  17. Rehearsal significantly improves immediate and delayed recall on the Rey Auditory Verbal Learning Test.

    PubMed

    Hessen, Erik

    2011-10-01

    A repeated observation during memory assessment with the Rey Auditory Verbal Learning Test (RAVLT) is that patients who spontaneously employ a memory rehearsal strategy by repeating the word list more than once achieve better scores than patients who only repeat the word list once. This observation led to concern about the ability of the standard test procedure of RAVLT and similar tests in eliciting the best possible recall scores. The purpose of the present study was to test the hypothesis that a rehearsal recall strategy of repeating the word list more than once would result in improved scores of recall on the RAVLT. We report on differences in outcome after standard administration and after experimental administration on Immediate and Delayed Recall measures from the RAVLT of 50 patients. The experimental administration resulted in significantly improved scores for all the variables employed. Additionally, it was found that patients who failed effort screening showed significantly poorer improvement on Delayed Recall compared with those who passed the effort screening. The general clear improvement both in raw scores and T-scores demonstrates that recall performance can be significantly influenced by the strategy of the patient or by small variations in instructions by the examiner.

  18. Diffuse cerebral symptoms in convalescents from cerebral infarction and myocardial infarction.

    PubMed

    Leegaard, O F

    1983-06-01

    In order to evaluate occurrence and cause of a number of diffuse cerebral symptoms (DCS), such as impaired memory, inability to concentrate, emotional instability, irritability, etc., 44 survivors of cerebral infarction (CI) and 40 survivors of myocardial infarction (MI) were seen 6-26 months after onset for psychometric testing and an interview about DCS. Although surprisingly common in both groups, DCS were significantly more frequent in CI patients than in MI patients. 1/2 of the former and 1/3 of the latter complained of 5 or more symptoms. In contrast, a significant difference in test performance was demonstrated in only 1 of 4 tests. There was no significant correlation between the number of DCS and test performance. In both groups, DCS occurrence was independent of age, whereas in the MI group, but not in the CI group, test performance was inversely related to age. In the CI group, DCS occurrence was not significantly related to size or site of the infarction. The results indicate that an organic brain damage cannot be the sole cause of DCS, and it is suggested that some of the symptoms are manifestations of a stress response syndrome provoked by insufficient coping with the consequences of the disease.

  19. Incremental diagnostic accuracy of hybrid SPECT/CT coronary angiography in a population with an intermediate to high pre-test likelihood of coronary artery disease.

    PubMed

    Schaap, Jeroen; Kauling, Robert M; Boekholdt, S Matthijs; Nieman, Koen; Meijboom, W Bob; Post, Martijn C; Van der Heyden, Jan A; de Kroon, Thom L; van Es, H Wouter; Rensing, Benno J; Verzijlbergen, J Fred

    2013-07-01

    Hybrid myocardial perfusion imaging with single photon emission computed tomography (SPECT) and CT coronary angiography (CCTA) has the potential to play a major role in patients with non-conclusive SPECT or CCTA results. We evaluated the performance of hybrid SPECT/CCTA vs. standalone SPECT and CCTA for the diagnosis of significant coronary artery disease (CAD) in patients with an intermediate to high pre-test likelihood of CAD. In total, 98 patients (mean age 62.5 ± 10.1 years, 68.4% male) with stable anginal complaints and a median pre-test likelihood of 87% (range 22-95%) were prospectively included in this study. Hybrid SPECT/CCTA was performed prior to conventional coronary angiography (CA) including fractional flow reserve (FFR) measurements. Hybrid analysis was performed by combined interpretation of SPECT and CCTA images. The sensitivity, specificity, positive (PPV), and negative (NPV) predictive values were calculated for standalone SPECT, CCTA, and hybrid SPECT/CCTA on per patient level, using an FFR <0.80 as a reference for significant CAD. Significant CAD was demonstrated in 56 patients (57.9%). Non-conclusive SPECT or CCTA results were found in 32 (32.7%) patients. SPECT had a sensitivity of 93%, specificity 79%, PPV 85%, and NPV 89%. CCTA had a sensitivity of 98%, specificity 62%, PPV 77%, and NPV 96%. Hybrid analysis of SPECT and CCTA improved the overall performance: sensitivity, specificity, PPV, and NPV for the presence of significant CAD to 96, 95, 96, and 95%, respectively. In > 40% of the patients with a high pre-test likelihood no significant CAD was demonstrated, emphasizing the value of accurate pre-treatment cardiovascular imaging. Hybrid SPECT/CCTA was able to accurately diagnose and exclude significant CAD surpassing standalone myocardial SPECT and CCTA, vs. a reference standard of FFR measurements.

  20. Evaluation of selected properties of a new root repair cement containing surface pre-reacted glass ionomer fillers.

    PubMed

    Yassen, Ghaeth H; Huang, Ruijie; Al-Zain, Afnan; Yoshida, Takamitsu; Gregory, Richard L; Platt, Jeffrey A

    2016-11-01

    This study evaluated selected properties of a prototype root repair cement containing surface pre-reacted glass ionomer fillers (S-PRG) in comparison to mineral trioxide aggregate (MTA) and intermediate restorative material (IRM). The antibacterial effect of S-PRG, MTA, and IRM cements was tested against Porphyromonas gingivalis and Enterococcus faecalis after 1 and 3 days of aging of the cements. The set cements were immersed in distilled water for 4 h to 28 days, and ion-releasing ability was evaluated. Initial and final setting times of all cements were evaluated using Gilmore needles. The push-out bond strength between radicular dentin and all cements was tested at different levels of the roots. S-PRG and IRM cements, but not MTA cement, demonstrated significant antibacterial effect against P. gingivalis. All types of cements exhibited significant antibacterial effect against E. faecalis without being able to eliminate the bacterium. S-PRG cement provided continuous release of fluoride, strontium, boron, sodium, aluminum, and zinc throughout all tested time points. Both initial and final setting times were significantly shorter for S-PRG and IRM cements in comparison to MTA. The push-out bond strength was significantly lower for S-PRG cement in comparison to MTA and IRM at coronal and middle levels of the roots. S-PRG cement demonstrated significant antibacterial effects against endodontic pathogens, multiple ion-releasing ability, relatively short setting time, and low bonding strength. S-PRG cement can be used as a one-visit root repair material with promising antibacterial properties and ion-releasing capacity.

  1. Color stability and degree of cure of direct composite restoratives after accelerated aging.

    PubMed

    Sarafianou, Aspasia; Iosifidou, Soultana; Papadopoulos, Triantafillos; Eliades, George

    2007-01-01

    This study evaluated the color changes and amount of remaining C = C bonds (%RDB) in three dental composites after hydrothermal- and photoaging. The materials tested were Estelite sigma, Filtek Supreme and Tetric Ceram. Specimens were fabricated from each material and subjected to L* a* b* colorimetry and FTIR spectroscopy before and after aging. Statistical evaluation of the deltaL,* deltaa,* deltab,* deltaE and %deltaRDB data was performed by one-way ANOVA and Tukey's test. The %RDB data before and after aging were statistically analyzed using two-way ANOVA and Student-Newman-Keuls test. In all cases an alpha = 0.05 significance level was used. No statistically significant differences were found in deltaL*, deltaa*, deltaE and %deltaRDB among the materials tested. Tetric Ceram demonstrated a significant difference in deltab*. All the materials showed visually perceptible (deltaE >1) but clinically acceptable values (deltaE < 3.3). Within each material group, statistically significant differences in %RDB were noticed before and after aging (p < 0.05). Filtek Supreme presented the lowest %RDB before aging, with Tetric Ceram presenting the lowest %RDB after aging (p < 0.05). The %deltaRDB mean values were statistically significantly different among all the groups tested. No correlation was found between deltaE and %deltaRDB.

  2. Visible spatial contiguity of social information and reward affects social learning in brown capuchins (Sapajus apella) and children (Homo sapiens).

    PubMed

    Wood, Lara A; Whiten, Andrew

    2017-11-01

    Animal social learning is typically studied experimentally by the presentation of artificial foraging tasks. Although productive, results are often variable even for the same species. We present and test the hypothesis that one cause of variation is that spatial distance between rewards and the means of reward release causes conflicts for participants' attentional focus. We investigated whether spatial contiguity between a visible reward and the means of release would affect behavioral responses that evidence social learning, testing 21 brown capuchins ( Sapajus apella ), a much-studied species with variant evidence for social learning, and one hundred eighty 2- to 4-year-old human children ( Homo sapiens ), a benchmark species known for a strong social learning disposition. Participants were presented with a novel transparent apparatus where a reward was either proximal or distal to a demonstrated means of releasing it. A distal reward location decreased attention toward the location of the demonstration and impaired subsequent success in gaining rewards. Generally, the capuchins produced the alternative method to that demonstrated, whereas children copied the method demonstrated, although a distal reward location reduced copying in younger children. We conclude that some design features in common social learning tasks may significantly degrade the evidence for social learning. We have demonstrated this for 2 different primates but suggest that it is a significant factor to control for in social learning research across all taxa. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  3. Space Shuttle program orbital flight test program results and implications

    NASA Technical Reports Server (NTRS)

    Kohrs, R. H.

    1982-01-01

    The Space Shuttle System Orbital Flight Test (OFT) program results are described along with an overview of significant development issues and their resolution. In addition, an overall summary of the development status and the follow-on flight demonstrations of Shuttle improvements such as Lightweight External Tank, High Performance SRBs, Full Power Level (109%) Main Engine Operation, and the SRB Filament Wound Case (FWC) will be discussed.

  4. Using Digital Image Correlation to Characterize Local Strains on Vascular Tissue Specimens.

    PubMed

    Zhou, Boran; Ravindran, Suraj; Ferdous, Jahid; Kidane, Addis; Sutton, Michael A; Shazly, Tarek

    2016-01-24

    Characterization of the mechanical behavior of biological and engineered soft tissues is a central component of fundamental biomedical research and product development. Stress-strain relationships are typically obtained from mechanical testing data to enable comparative assessment among samples and in some cases identification of constitutive mechanical properties. However, errors may be introduced through the use of average strain measures, as significant heterogeneity in the strain field may result from geometrical non-uniformity of the sample and stress concentrations induced by mounting/gripping of soft tissues within the test system. When strain field heterogeneity is significant, accurate assessment of the sample mechanical response requires measurement of local strains. This study demonstrates a novel biomechanical testing protocol for calculating local surface strains using a mechanical testing device coupled with a high resolution camera and a digital image correlation technique. A series of sample surface images are acquired and then analyzed to quantify the local surface strain of a vascular tissue specimen subjected to ramped uniaxial loading. This approach can improve accuracy in experimental vascular biomechanics and has potential for broader use among other native soft tissues, engineered soft tissues, and soft hydrogel/polymeric materials. In the video, we demonstrate how to set up the system components and perform a complete experiment on native vascular tissue.

  5. Treatment of periodontal intrabony defects using β-TCP alone or in combination with rhPDGF-BB: a randomized controlled clinical and radiographic study.

    PubMed

    Maroo, Sneha; Murthy, K Raja V

    2014-01-01

    The need to increase the predictability of periodontal regeneration has encouraged clinicians and researchers to employ cell-stimulating proteins in combination with osteoconductive scaffolds, based on the principles of tissue engineering. The purpose of this clinical and radiographic study was to compare the regenerative potential of the combination of β-tricalcium phosphate (β-TCP) and recombinant human platelet-derived growth factor BB (rhPDGF-BB) in the grafting of intraosseous defects with the established technique of bone grafting with (β-TCP alone. A total of 30 sites from 15 patients with infrabony defects in two different quadrants were selected, and the sites were randomly divided into test sites (rhPDGF + β-TCP) and control sites (β-TCP alone) using a split-mouth design. Clinical parameters, including probing pocket depth, clinical attachment level, and gingival recession, were recorded at baseline, 6 months, and 9 months. Radiographic evaluation was carried out to evaluate defect fill, change in alveolar crest height, and percentage of defect fill at baseline, 6 months, and 9 months. Both the experimental groups showed statistically significant reduction in probing pocket depth and gain in clinical attachment level. On intergroup comparison, sites treated with rhPDGF + β-TCP demonstrated a significantly greater pocket depth reduction (P < .05) and greater gain in clinical attachment level (P < .01). Mean percentage defect fill was significantly greater in test sites as compared with control sites at 6 and 9 months (P < .01). rhPDGF + β-TCP-treated sites demonstrated a significant gain in mean alveolar crest height at 6 and 9 months (P < .05), while β-TCP-treated sites demonstrated crestal resorption. Both groups demonstrated potential in enhancing periodontal regeneration; however, on comparison between the two groups, the results obtained by rhPDGF + β-TCP were significantly better with respect to both clinical and radiographic parameters.

  6. Antibacterial activity of Greek and Cypriot honeys against Staphylococcus aureus and Pseudomonas aeruginosa in comparison to manuka honey.

    PubMed

    Anthimidou, Eleni; Mossialos, Dimitris

    2013-01-01

    The antibacterial activity of 31 Greek and Cypriot honeys against Staphylococcus aureus and Pseudomonas aeruginosa was initially screened using an agar-well diffusion assay in comparison with manuka honey. The minimum inhibitory concentration (MIC) was determined in broth using a spectrophotometric-based assay. The MIC of treated honeys with catalase or proteinase K was determined and compared with those of untreated honeys. All tested honeys demonstrated antibacterial activity against S. aureus on agar-well diffusion assay. MICs of tested honeys were determined as 3.125-25% (v/v), compared with manuka honey at 6.25% (v/v). Similarly, 21 of 31 tested honeys demonstrated antibacterial activity on agar-well diffusion assay against P. aeruginosa. Their MICs ranged from 6.25% to 25% (v/v) compared with 12.5% (v/v) for manuka honey. Antibacterial activity of tested honeys could be largely attributed to hydrogen peroxide formation and in some cases to unidentified proteinaceous compounds. In conclusion, Greek and Cypriot honeys demonstrated significant but variable antibacterial activity against P. aeruginosa and especially S. aureus. To the best of our knowledge this is the first study that has thoroughly examined the antibacterial activity of Greek and Cypriot honeys compared with manuka honey. The high antibacterial activity exerted by some tested honeys warrants further investigation.

  7. Online virtual-patient cases versus traditional problem-based learning in advanced pharmacy practice experiences.

    PubMed

    Al-Dahir, Sara; Bryant, Kendrea; Kennedy, Kathleen B; Robinson, Donna S

    2014-05-15

    To evaluate the efficacy of faculty-led problem-based learning (PBL) vs online simulated-patient case in fourth-year (P4) pharmacy students. Fourth-year pharmacy students were randomly assigned to participate in either online branched-case learning using a virtual simulation platform or a small-group discussion. Preexperience and postexperience student assessments and a survey instrument were completed. While there were no significant differences in the preexperience test scores between the groups, there was a significant increase in scores in both the virtual-patient group and the PBL group between the preexperience and postexperience tests. The PBL group had higher postexperience test scores (74.8±11.7) than did the virtual-patient group (66.5±13.6) (p=0.001). The PBL method demonstrated significantly greater improvement in postexperience test scores than did the virtual-patient method. Both were successful learning methods, suggesting that a diverse approach to simulated patient cases may reach more student learning styles.

  8. Flight tests of external modifications used to reduce blunt base drag

    NASA Technical Reports Server (NTRS)

    Powers, Sheryll Goecke

    1988-01-01

    The effectiveness of a trailing disk (the trapped vortex concept) in reducing the blunt base drag of an 8-in diameter body of revolution was studied from measurements made both in flight and in full-scale wind-tunnel tests. The experiment demonstrated the significant base drag reduction capability of the trailing disk to Mach 0.93. The maximum base drag reduction obtained from a cavity tested on the flight body of revolution was not significant. The effectiveness of a splitter plate and a vented-wall cavity in reducing the base drag of a quasi-two-dimensional fuselage closure was studied from base pressure measurements made in flight. The fuselage closure was between the two engines of the F-111 airplane; therefore, the base pressures were in the presence of jet engine exhaust. For Mach numbers from 1.10 to 1.51, significant base drag reduction was provided by the vented-wall cavity configuration. The splitter plate was not considered effective in reducing base drag at any Mach number tested.

  9. Brain Microstructural Correlates of Cognitive Dysfunction in Clinically and Biochemically Normal Hepatitis C Virus Infection.

    PubMed

    Kumar, Ajay; Deep, Amar; Gupta, Rakesh K; Atam, Virendra; Mohindra, Samir

    2017-09-01

    This study examined correlates of the brain's neurocognitive performance among clinically and biochemically normal adult patient with hepatitis C virus (HCV). We hypothesized that anti-HCV positive individuals would demonstrate structural brain abnormalities and neurocognitive dysfunction as well as the changes in cell component and extracellular space in the white matter regions of brain in asymptomatic HCV infection by using diffusion tensor tractrography (DTT) metrics. Anti-HCV positive patient ( n  = 40), and healthy controls ( n  = 31), fulfilling inclusion criteria (incidentally detected anti-HCV positive) and able to provide informed consent were screened and recruited for the study. All these subjects and controls underwent subjective assessment of their quality of life related symptoms, neuropsychometric tests (NPT) and magnetic resonance imaging. The patients were subjected to neuroimaging as well as psychological testing. There was no significant difference in basic laboratory parameters in these two groups. Independent t -test reveals significantly lower neuropsychological functioning as compared to healthy control. A significantly decreased FA values and myoinsitol were observed in HCV subjects on sensory, inferior longitudinal fascicules, and STR fiber bundles as compared to healthy control. Bivariate correlation analysis reveals that neuropsychological scores are significantly positive. Our result show that HCV positive individuals would demonstrate structural brain abnormalities and neurocognitive dysfunction as well as the changes in cell component and extracellular space in the white matter regions of brain in asymptomatic HCV infection by using DTT metrics.

  10. Flight test experience using advanced airborne equipment in a time-based metered traffic environment

    NASA Technical Reports Server (NTRS)

    Morello, S. A.

    1980-01-01

    A series of test flights have demonstrated that time-based metering guidance and control was acceptable to pilots and air traffic controllers. The descent algorithm of the technique, with good representation of aircraft performance and wind modeling, yielded arrival time accuracy within 12 sec. It is expected that this will represent significant fuel savings (1) through a reduction of the time error dispersions at the metering fix for the entire fleet, and (2) for individual aircraft as well, through the presentation of guidance for a fuel-efficient descent. Air traffic controller workloads were also reduced, in keeping with the reduction of required communications resulting from the transfer of navigation responsibilities to pilots. A second series of test flights demonstrated that an existing flight management system could be modified to operate in the new mode.

  11. Effect of Cuscuta reflexa stem and Calotropis procera leaf extracts on glucose tolerance in glucose-induced hyperglycemic rats and mice.

    PubMed

    Rahmatullah, Mohammed; Sultan, Shamsuddin; Toma, Tanzila Taher; Lucky, Sayeda-A-Safa; Chowdhury, Majeedul H; Haque, Wahid Mozammel; Annay, Eashmat Ara; Jahan, Rownak

    2009-12-30

    Cuscuta reflexa (whole plant) and Calotropis procera (leaves) are used in folk medicine of Bangladesh to control blood sugar in patients suffering from diabetes mellitus. The hypoglycemic effects of methanol and chloroform extracts of whole plants of Cuscuta reflexa, and methanol extract of leaves of Calotropis procera were investigated in oral glucose tolerance tests in Long Evans rats and Swiss albino mice, respectively. Both methanol and chloroform extracts of Cuscuta reflexa whole plant demonstrated significant oral hypoglycemic activity in glucose-loaded rats at doses of 50, 100 and 200 mg/kg body weight. The methanol extract of leaves of Calotropis procera, when tested at doses of 100 and 250 mg/kg body weight did not demonstrate any oral hypoglycemic effect when tested in glucose-loaded mice.

  12. Physiological effects of bioceramic material: harvard step, resting metabolic rate and treadmill running assessments.

    PubMed

    Leung, Ting-Kai; Kuo, Chia-Hua; Lee, Chi-Ming; Kan, Nai-Wen; Hou, Chien-Wen

    2013-12-31

    Previous biomolecular and animal studies have shown that a room-temperature far-infrared-rayemitting ceramic material (bioceramic) demonstrates physical-biological effects, including the normalization of psychologically induced stress-conditioned elevated heart rate in animals. In this clinical study, the Harvard step test, the resting metabolic rate (RMR) assessment and the treadmill running test were conducted to evaluate possible physiological effects of the bioceramic material in human patients. The analysis of heart rate variability (HRV) during the Harvard step test indicated that the bioceramic material significantly increased the high-frequency (HF) power spectrum. In addition, the results of RMR analysis suggest that the bioceramic material reduced oxygen consumption (VO2). Our results demonstrate that the bioceramic material has the tendency to stimulate parasympathetic responses, which may reduce resting energy expenditure and improve cardiorespiratory recovery following exercise.

  13. Evaluation of a low-cost liquid-based Pap test in rural El Salvador: a split-sample study.

    PubMed

    Guo, Jin; Cremer, Miriam; Maza, Mauricio; Alfaro, Karla; Felix, Juan C

    2014-04-01

    We sought to test the diagnostic efficacy of a low-cost, liquid-based cervical cytology that could be implemented in low-resource settings. A prospective, split-sample Pap study was performed in 595 women attending a cervical cancer screening clinic in rural El Salvador. Collected cervical samples were used to make a conventional Pap (cell sample directly to glass slide), whereas residual material was used to make the liquid-based sample using the ClearPrep method. Selected samples were tested from the residual sample of the liquid-based collection for the presence of high-risk Human papillomaviruses. Of 595 patients, 570 were interpreted with the same diagnosis between the 2 methods (95.8% agreement). There were comparable numbers of unsatisfactory cases; however, ClearPrep significantly increased detection of low-grade squamous intraepithelial lesions and decreased the diagnoses of atypical squamous cells of undetermined significance. ClearPrep identified an equivalent number of high-grade squamous intraepithelial lesion cases as the conventional Pap. High-risk human papillomavirus was identified in all cases of high-grade squamous intraepithelial lesion, adenocarcinoma in situ, and cancer as well as in 78% of low-grade squamous intraepithelial lesions out of the residual fluid of the ClearPrep vials. The low-cost ClearPrep Pap test demonstrated equivalent detection of squamous intraepithelial lesions when compared with the conventional Pap smear and demonstrated the potential for ancillary molecular testing. The test seems a viable option for implementation in low-resource settings.

  14. Protective effect of treatment with black cumin oil on spatial cognitive functions of rats that suffered global cerebrovascular hypoperfusion.

    PubMed

    Azzubaidi, Marwan Saad; Saxena, Anil Kumar; Talib, Norlelawati Abi; Ahmed, Qamar Uddin; Dogarai, Bashar Bello

    2012-01-01

    The fixed oil of black cumin seeds, Nigella sativa L. (NSO), has shown considerable antioxidant and anti-inflammatory activities. Chronic cerebral hypoperfusion has been linked to neurodegenerative disorders including Alzheimer's disease (AD) and its subsequent cognitive impairment in which oxidative stress and neuroinflammation are the principal culprits. Cerebrovascular hypoperfusion was experimentally achieved by bilateral common carotid arteries occlusion (2VO) in rats. Morris water maze (MWM) test was employed to assess the effects of NSO on spatial cognitive function before and after 2VO intervention. Rats were divided into long-term memory (LTM) and short-term memory (STM) groups, each was further subdivided into 3 subgroups: sham control, untreated 2VO and NSO treated 2VO group. All subgroups were tested with MWM at the tenth postoperative week. Working memory test results for both sham control and NSO treated groups showed significantly lower escape latency time and total distance travelled than untreated 2VO group. Similarly, LTM and STM MWM tests for sham control and NSO treated groups revealed significantly better maze test performance as compared to untreated 2VO group. Sham control and NSO treated 2VO groups demonstrated superior probe memory test performance as compared to untreated 2VO group. The fixed oil of Nigella sativa seeds has demonstrated noticeable spatial cognitive preservation in rats challenged with chronic cerebral hypoperfusion which indicates a promising prospective neuroprotective effect.

  15. CRYogenic Orbital TEstbed Ground Test Article Thermal Analysis

    NASA Technical Reports Server (NTRS)

    Piryk, David; Schallhorn, Paul; Walls, Laurie; Stopnitzky, Benny; Rhys, Noah; Wollen, Mark

    2012-01-01

    The purpose of this study was to anchor thermal and fluid system models to CRYOTE ground test data. The CRYOTE ground test artide was jointly developed by Innovative Engineering Solutions, United Launch Alliance and NASA KSC. The test article was constructed out of a titanium alloy tank, Sapphire 77 composite skin (similar to G10), an external secondary payload adapter ring, thermal vent system, multi layer insulation and various data acquisition instrumentation. In efforts to understand heat loads throughout this system, the GTA (filled with liquid nitrogen for safety purposes) was subjected to a series of tests in a vacuum chamber at Marshall Space Flight Center. By anchoring analytical models against test data, higher fidelity thermal environment predictions can be made for future flight articles which would eventually demonstrate critical cryogenic fluid management technologies such as system chilldown, transfer, pressure control and long term storage. Significant factors that influenced heat loads included radiative environments, multi-layer insulation performance, tank fill levels and pressures and even contact conductance coefficients. This report demonstrates how analytical thermal/fluid networks were established and includes supporting rationale for specific thermal responses.

  16. Dietary supplementation with low-dose omega-3 fatty acids reduces salivary tumor necrosis factor-α levels in patients with chronic periodontitis: a randomized controlled clinical study.

    PubMed

    Keskiner, I; Saygun, I; Bal, V; Serdar, M; Kantarci, A

    2017-08-01

    Recent studies have demonstrated the beneficial effects of omega-3 polyunsaturated fatty acids (PUFAs) on physiological processes and on a variety of chronic inflammatory diseases, including periodontal diseases. In this study, we evaluated the impact of omega-3 PUFAs in conjunction with scaling and root planing (SRP) on salivary markers in patients with chronic periodontitis. Thirty systemically healthy subjects with chronic periodontitis were enrolled and randomly allocated into two groups. The control group (n = 15) was treated with SRP + placebo whereas the test group was treated with SRP and dietary supplementation of low-dose omega-3 PUFAs (6.25 mg eicosapentaenoic acid and 19.19 mg docosahexaenoic acid). Clinical parameters were taken at baseline, 1, 3 and 6 mo following therapy. Saliva samples were obtained at the same time intervals and analyzed for tumor necrosis factor-α (TNF-α) and superoxide dismutase (SOD). Both groups showed significant changes in clinical parameters in response to treatment compared to baseline with no significant difference between groups. Salivary TNF-α levels showed a statistically significant decrease in the test group at 6 mo compared to the control group. Salivary SOD levels increased significantly at 3 and 6 mo in the test group and at 6 mo in placebo groups compared to baseline with no statistically significant differences between the groups. The results demonstrated that dietary supplementation with low-dose omega-3 PUFAs improves salivary TNF-α without any significant impact on clinical parameters in patients with chronic periodontitis, suggesting that the systemic benefits of dietary omega-3 PUFAs may not be translated to periodontal health. (ClinicalTrials.gov ID NCT02719587). © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Using the Teach-Back Method in Patient Education to Improve Patient Satisfaction.

    PubMed

    Centrella-Nigro, Andrea M; Alexander, Catherine

    2017-01-01

    This quasi-experimental research study used two similar nursing units to test the effects of teach back on Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) scores. A pretest-posttest design tested 24 nurses' knowledge, attitudes, and beliefs about teach back. Education specialists provided a 1-hour teaching session on teach back to all nurses in the intervention unit. A significant improvement in knowledge scores in the pretest-posttest was found using paired t tests (p = .002). Qualitative analysis of nurses' comments demonstrated strong support for teach back in the post-test. The HCAHPS scores were not significantly improved in the intervention unit when compared with the control unit. More research needs to be conducted to determine the effectiveness of teach back on HCAHPS scores. J Contin Educ Nurs. 2017;48(1):47-52. Copyright 2017, SLACK Incorporated.

  18. Nursing students' mathematic calculation skills.

    PubMed

    Rainboth, Lynde; DeMasi, Chris

    2006-12-01

    This mixed method study used a pre-test/post-test design to evaluate the efficacy of a teaching strategy in improving beginning nursing student learning outcomes. During a 4-week student teaching period, a convenience sample of 54 sophomore level nursing students were required to complete calculation assignments, taught one calculation method, and mandated to attend medication calculation classes. These students completed pre- and post-math tests and a major medication mathematic exam. Scores from the intervention student group were compared to those achieved by the previous sophomore class. Results demonstrated a statistically significant improvement from pre- to post-test and the students who received the intervention had statistically significantly higher scores on the major medication calculation exam than did the students in the control group. The evaluation completed by the intervention group showed that the students were satisfied with the method and outcome.

  19. DEVELOPMENT OF SRB TREATMENT SYSTEMS FOR ACID MINE DRAINAGE

    EPA Science Inventory

    Over the past decade, significant advances have been made in the development of sulfate- reducing bacteria (SRB) technology to treat acid mine drainage (AMD), Bench-scale testing, field demonstrations, and engineered applications of SRBs for the treatment of AMD will be presented...

  20. DESIGN AND TESTING OF SECOND GENERATION BIOREMEDIATION TECHNOLOGIES FOR CHLORINATED SOLVENT CONTAMINATED SITES

    EPA Science Inventory

    The contamination of ground water at industrial and military facilities by chlorinated solvents remains a significant environmental challenge. In the 1990's several successful demonstrations of in situ biodegradation processes, targeted for chloroethenes, occurred. While these tr...

  1. Psychological Adjustment of Siblings to a Child with Diabetes.

    ERIC Educational Resources Information Center

    Hollidge, Colin

    2001-01-01

    Examines the psychological adjustment of well child siblings living with siblings with diabetes. Psychological adjustment was assessed by measuring self-concept; behavioral difficulties; competence; anxiety; and depression on standardized tests. The well siblings demonstrated significant internal psychological stressors and maintained high levels…

  2. Creep fatigue life prediction for engine hot section materials (isotropic)

    NASA Technical Reports Server (NTRS)

    Nelson, R. S.; Levan, G. W.; Schoendorf, J. F.

    1992-01-01

    A series of high temperature strain controlled fatigue tests have been completed to study the effects of thermomechanical fatigue, multiaxial loading, reactive environments, and imposed mean stresses. The baseline alloy used in these tests was cast B1900+Hf (with and without coatings); a small number of tests of wrought INCO 718 are also included. A strong path dependence was demonstrated during the thermomechanical fatigue testing, using in-phase, out-phase, and non-proportional (elliptical and 'dogleg') strain-temperature cycles. The multiaxial tests also demonstrated cycle path to be a significant variable, using both proportional and non-proportional tension-torsion loading. Environmental screening tests were conducted in moderate pressure oxygen and purified argon; the oxygen reduced the specimen lives by two, while the argon testing produced ambiguous data. Both NiCoCrAlY overlay and diffusion aluminide coatings were evaluated under isothermal and TMF conditions; in general, the lives of the coated specimens were higher that those of uncoated specimens. Controlled mean stress TMF tests showed that small mean stress changes could change initiation lives by orders of magnitude; these results are not conservatively predicted using traditional linear damage summation rules. Microstructures were evaluated using optical, SEM and TEM methods.

  3. Osseodensification for enhancement of spinal surgical hardware fixation.

    PubMed

    Lopez, Christopher D; Alifarag, Adham M; Torroni, Andrea; Tovar, Nick; Diaz-Siso, J Rodrigo; Witek, Lukasz; Rodriguez, Eduardo D; Coelho, Paulo G

    2017-05-01

    Integration between implant and bone is an essential concept for osseous healing requiring hardware placement. A novel approach to hardware implantation, termed osseodensification, is described here as an effective alternative. 12 sheep averaging 65kg had fixation devices installed in their C2, C3, and C4 vertebral bodies; each device measured 4mm diameter×10mm length. The left-sided vertebral body devices were implanted using regular surgical drilling (R) while the right-sided devices were implanted using osseodensification drilling (OD). The C2 and C4 vertebra provided the t=0 in vivo time point, while the C3 vertebra provided the t=3 and t=6 week time points, in vivo. Structural competence of hardware was measured using biomechanical testing of pullout strength, while the quality and degree of new bone formation and remodeling was assessed via histomorphometry. Pullout strength demonstrated osseodensification drilling to provide superior anchoring when compared to the control group collapsed over time with statistical significance (p<0.01). On Wilcoxon rank signed test, C2 and C4 specimens demonstrated significance when comparing device pullout (p=0.031) for both, and C3 pullout tests at 3 and 6 weeks collapsed over time had significance as well (p=0.027). Percent bone-to-implant contact (%BIC) analysis as a function of drilling technique demonstrated an OD group with significantly higher values relative to the R group (p<0.01). Similarly, percent bone-area-fraction-occupancy (BAFO) analysis presented with significantly higher values for the OD group compared to the R group (p=0.024). As a function of time, between 0 and 3 weeks, a decrease in BAFO was observed, a trend that reversed between 3 and 6 weeks, resulting in a BAFO value roughly equivalent to the t=0 percentage, which was attributed to an initial loss of bone fraction due to remodeling, followed by regaining of bone fraction via production of woven bone. Histomorphological data demonstrated autologous bone chips in the OD group with greater frequency relative to the control, which acted as nucleating surfaces promoting new bone formation around the implants, providing superior stability and greater bone density. This alternative approach to a critical component of hardware implantation encourages assessment of current surgical approaches to hardware implantation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Osseodensification for enhancement of spinal surgical hardware fixation

    PubMed Central

    Lopez, Christopher D.; Alifarag, Adham M.; Torroni, Andrea; Tovar, Nick; Diaz-Siso, J. Rodrigo; Witek, Lukasz; Rodriguez, Eduardo D.; Coelho, Paulo G.

    2017-01-01

    Integration between implant and bone is an essential concept for osseous healing requiring hardware placement. A novel approach to hardware implantation, termed osseodensification, is described here as an effective alternative. 12 sheep averaging 65 kg had fixation devices installed in their C2, C3, and C4 vertebral bodies; each device measured 4 mm diameter×10 mm length. The left-sided vertebral body devices were implanted using regular surgical drilling (R) while the right-sided devices were implanted using osseodensification drilling (OD). The C2 and C4 vertebra provided the t=0 in vivo time point, while the C3 vertebra provided the t=3 and t=6 week time points, in vivo. Structural competence of hardware was measured using biomechanical testing of pullout strength, while the quality and degree of new bone formation and remodeling was assessed via histomorphometry. Pullout strength demonstrated osseodensification drilling to provide superior anchoring when compared to the control group collapsed over time with statistical significance (p < 0.01). On Wilcoxon rank signed test, C2 and C4 specimens demonstrated significance when comparing device pullout (p=0.031) for both, and C3 pullout tests at 3 and 6 weeks collapsed over time had significance as well (p=0.027). Percent bone-to-implant contact (%BIC) analysis as a function of drilling technique demonstrated an OD group with significantly higher values relative to the R group (p < 0.01). Similarly, percent bone-area-fraction-occupancy (BAFO) analysis presented with significantly higher values for the OD group compared to the R group (p=0.024). As a function of time, between 0 and 3 weeks, a decrease in BAFO was observed, a trend that reversed between 3 and 6 weeks, resulting in a BAFO value roughly equivalent to the t=0 percentage, which was attributed to an initial loss of bone fraction due to remodeling, followed by regaining of bone fraction via production of woven bone. Histomorphological data demonstrated autologous bone chips in the OD group with greater frequency relative to the control, which acted as nucleating surfaces promoting new bone formation around the implants, providing superior stability and greater bone density. This alternative approach to a critical component of hardware implantation encourages assessment of current surgical approaches to hardware implantation. PMID:28113132

  5. Design and Development of a Rapid Research, Design, and Development Platform for In-Situ Testing of Tools and Concepts for Trajectory-Based Operations

    NASA Technical Reports Server (NTRS)

    Underwood, Matthew C.

    2017-01-01

    To provide justification for equipping a fleet of aircraft with avionics capable of supporting trajectory-based operations, significant flight testing must be accomplished. However, equipping aircraft with these avionics and enabling technologies to communicate the clearances required for trajectory-based operations is cost-challenging using conventional avionics approaches. This paper describes an approach to minimize the costs and risks of flight testing these technologies in-situ, discusses the test-bed platform developed, and highlights results from a proof-of-concept flight test campaign that demonstrates the feasibility and efficiency of this approach.

  6. Antimicrobial and anti-adherence activity of various combinations of coffee-chicory solutions on Streptococcus mutans: An in-vitro study

    PubMed Central

    Sharma, Rama; Reddy, Vamsi Krishna L; Prashant, GM; Ojha, Vivek; Kumar, Naveen PG

    2014-01-01

    Context: Several studies have demonstrated the activity of natural plants on the dental biofilm and caries development. But few studies on the antimicrobial activity of coffee-based solutions were found in the literature. Further there was no study available to check the antimicrobial effect of coffee solutions with different percentages of chicory in it. Aims: To evaluate the antimicrobial activity of different combinations of coffee-chicory solutions and their anti-adherence effect on Streptococcus mutans to glass surface. Materials and Methods: Test solutions were prepared. For antimicrobial activity testing, tubes containing test solution and culture medium were inoculated with a suspension of S. mutans followed by plating on Brain Heart Infusion (BHI) agar. S. mutans adherence to glass in presence of the different test solutions was also tested. The number of adhered bacteria (CFU/mL) was determined by plating method. Statistical Analysis: Statistical significance was measured using one way ANOVA followed by Tukey's post hoc test. P value < 0.05 was considered statistically significant. Results: Pure chicory had shown significantly less bacterial count compared to all other groups. Groups IV and V had shown significant reduction in bacterial counts over the period of 4 hrs. Regarding anti-adherence effect, group I-IV had shown significantly less adherence of bacteria to glass surface. Conclusions: Chicory exerted antibacterial effect against S. mutans while coffee reduced significantly the adherence of S. mutans to the glass surface. PMID:25328299

  7. Stress hormones at rest and following exercise testing predict coronary artery disease severity and outcome.

    PubMed

    Popovic, Dejana; Damjanovic, Svetozar; Djordjevic, Tea; Martic, Dejana; Ignjatovic, Svetlana; Milinkovic, Neda; Banovic, Marko; Lasica, Ratko; Petrovic, Milan; Guazzi, Marco; Arena, Ross

    2017-09-01

    Despite considerable knowledge regarding the importance of stress in coronary artery disease (CAD) pathogenesis, its underestimation persists in routine clinical practice, in part attributable to lack of a standardized, objective assessment. The current study examined the ability of stress hormones to predict CAD severity and prognosis at basal conditions as well as during and following an exertional stimulus. Forty Caucasian subjects with significant coronary artery lesions (≥50%) were included. Within 2 months of coronary angiography, cardiopulmonary exercise testing (CPET) on a recumbent ergometer was performed in conjunction with stress echocardiography (SE). At rest, peak and after 3 min of recovery following CPET, plasma levels of cortisol, adrenocorticotropic hormone (ACTH) and NT-pro-brain natriuretic peptide (NT-pro-BNP) were measured by immunoassay sandwich technique, radioimmunoassay, and radioimmunometric technique, respectively. Subjects were subsequently followed a mean of 32 ± 10 months. Mean ejection fraction was 56.7 ± 9.6%. Subjects with 1-2 stenotic coronary arteries (SCA) demonstrated a significantly lower plasma cortisol levels during CPET compared to those with 3-SCA (p < .05), whereas ACTH and NT-pro-BNP were not significantly different (p > .05). Among CPET, SE, and hormonal parameters, cortisol at rest and during CPET recovery demonstrated the best predictive value in distinguishing between 1-, 2-, and 3-SCA [area under ROC curve 0.75 and 0.77 (SE = 0.11, 0.10; p = .043, .04) for rest and recovery, respectively]. ΔCortisol peak/rest predicted cumulative cardiac events (area under ROC curve 0.75, SE = 0.10, p = .049). Cortisol at rest and following an exercise test holds predictive value for CAD severity and prognosis, further demonstrating a link between stress and unwanted cardiac events.

  8. Asbestos-induced autoimmunity in C57BL/6 mice.

    PubMed

    Pfau, Jean C; Sentissi, Jami J; Li, Sheng'ai; Calderon-Garciduenas, Lilian; Brown, Jared M; Blake, David J

    2008-04-01

    Environmental impacts on autoimmunity have significant public health implications. Epidemiological studies have shown associations between exposure to airborne silicates, such as crystalline silica or asbestos, and autoimmunity, but the etiology remains unclear. The purpose of this study was to test the hypothesis that asbestos could lead to a specific pattern of autoantibodies and pathology indicative of systemic autoimmune disease (SAID). Female C57Bl/6 mice were instilled intratracheally with 2 doses x 60 microg/mouse of amphibole asbestos (tremolite), wollastonite (a non-fibrogenic control fiber), or saline alone. Serum samples were collected and urine was checked for protein bi-weekly for 7 months. By 26 weeks, the asbestos-instilled animals had a significantly higher frequency of positive anti-nuclear antibody (ANA) tests compared to wollastonite and saline groups. The majority of positive ANAs showed homogeneous or combined homogeneous/speckled patterns, and tested positive for antibodies to dsDNA and SSA/Ro 52. Serum isotyping showed no significant changes in IgM, IgA, or IgG subclasses. However, there was an overall decrease in the mean IgG serum concentration in asbestos-instilled mice. IgG immune complex deposition was demonstrated in the kidneys of asbestos-instilled mice, with evidence of glomerular and tubule abnormalities suggestive of glomerulonephritis. Flow cytometry demonstrated moderate changes in the percentages of CD25+ T-suppressor cells and B1a B-cells in the superficial cervical lymph nodes of the asbestos-instilled mice. These data demonstrate that asbestos leads to immunologic changes consistent with the development of autoimmunity. This study provides a non-autoimmune prone murine model for use in future elucidation of mechanisms involved in asbestos-induced autoimmune disease.

  9. Exercise-induced Hypoalgesia in People With Knee Osteoarthritis With Normal and Abnormal Conditioned Pain Modulation.

    PubMed

    Fingleton, Caitríona; Smart, Keith M; Doody, Catherine M

    2017-05-01

    Normal efficiency of exercise-induced hypoalgesia (EIH) has been demonstrated in people with knee osteoarthritis (OA), while recent evidence suggests that EIH may be associated with features of pain sensitization such as abnormal conditioned pain modulation (CPM). The aim of this study was to investigate whether people with knee OA with abnormal CPM have dysfunctional EIH compared with those with normal CPM and pain-free controls. Forty peoples with knee OA were subdivided into groups with abnormal and normal CPM, as determined by a decrease/increase in pressure pain thresholds (PPTs) following the cold pressor test. Abnormal CPM (n=19), normal CPM (n=21), and control participants (n=20) underwent PPT testing before, during, and after aerobic and isometric exercise protocols. Between-group differences were analyzed using repeated-measures analysis of variance and within-group differences were analyzed using Wilcoxon signed-rank tests. Significant differences were demonstrated between groups for changes in PPTs postaerobic (F2,55=4.860; P=0.011) and isometric (F2,57=4.727; P=0.013) exercise, with significant decreases in PPTs demonstrated during and postexercise in the abnormal CPM group (P<0.05), and significant increases in PPTs shown during and postexercise in the normal CPM and control groups (P<0.05). Results are suggestive of dysfunctional EIH in response to aerobic and isometric exercise in knee OA patients with abnormal CPM, and normal function of EIH in knee OA patients with an efficient CPM response. Identification of people with knee OA with inefficient endogenous pain modulation may allow for a more individualized and graded approach to exercises in these individuals.

  10. Stratum corneum profiles of inflammatory mediators in patch test reactions to common contact allergens and sodium lauryl sulfate.

    PubMed

    Koppes, S A; Ljubojevic Hadzavdic, S; Jakasa, I; Franceschi, N; Jurakić Tončić, R; Marinović, B; Brans, R; Gibbs, S; Frings-Dresen, M H W; Rustemeyer, T; Kezic, S

    2017-06-01

    Recent studies have demonstrated allergen-specific differences in the gene expression of inflammatory mediators in patch tested skin. To determine levels of various inflammatory mediators in the stratum corneum (SC) after patch testing with common contact allergens and the skin irritant sodium lauryl sulfate (SLS). In total, 27 individuals who had previously patch tested positive to nickel, chromium, methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) or para-phenylenediamine were retested and then patch tested with SLS and petrolatum, with petrolatum serving as the patch test control. At 72 h, the test sites were clinically graded and the SC samples collected on adhesive tape. The levels of 18 of the 32 quantified mediators differed significantly from that of the control patches for at least one of the tested substances. SLS and MCI/MI induced the largest number of immunomediators. Interleukin (IL)-16 levels were significantly higher in patch test reactions in all allergens than they were in the controls, while no significant difference was detected for SLS. Furthermore, a strong negative correlation was found between strength of patch test reaction and IL-1α levels. Cytokine profiles in the SC of patch tested skin did not show a distinct allergen-specific pattern. However, MCI/MI induced a larger and wider immune response than the other allergens, perhaps due to its potency as an irritant. The levels of IL-16 were significantly increased in patch test reactions to allergens but not to SLS; thus, they may help clinicians to differentiate between allergic contact dermatitis and irritant contact dermatitis. © 2016 British Association of Dermatologists.

  11. THE CLINICAL, FUNCTIONAL AND BIOMECHANICAL PRESENTATION OF PATIENTS WITH SYMPTOMATIC HIP ABDUCTOR TENDON TEARS

    PubMed Central

    Retheesh, Theertha; Mutreja, Rinky; Janes, Gregory C.

    2016-01-01

    Background Hip abductor tendon (HAT) tearing is commonly implicated in greater trochanteric pain syndrome (GTPS), though limited information exists on the disability associated with this condition and specific presentation of these patients. Purpose To describe the clinical, functional and biomechanical presentation of patients with symptomatic HAT tears. Secondary purposes were to investigate the association between these clinical and functional measures, and to compare the pain and disability reported by HAT tear patients to those with end-stage hip osteoarthritis (OA). Study Design Prospective case series. Methods One hundred forty-nine consecutive patients with symptomatic HAT tears were evaluated using the Harris (HHS) and Oxford (OHS) Hip Scores, SF-12, an additional series of 10 questions more pertinent to those with lateral hip pain, active hip range of motion (ROM), maximal isometric hip abduction strength, six-minute walk capacity and 30-second single limb stance (SLS) test. The presence of a Trendelenburg sign and pelvis-on-femur (POF) angle were determined via 2D video analysis. An age matched comparative sample of patients with end-stage hip OA was recruited for comparison of all patient-reported outcome scores. Independent t-tests investigated group and limb differences, while analysis of variance evaluated pain changes during the functional tests. Pearson's correlation coefficients investigated the correlation between clinical measures in the HAT tear group. Results No differences existed in patient demographics and patient-reported outcome scores between HAT tear and hip OA cohorts, apart from significantly worse SF-12 mental subscale scores (p = 0.032) in the HAT tear group. Patients with HAT tears demonstrated significantly lower (p < 0.05) hip abduction strength and active ROM in all planes of motion on their affected limb. Pain significantly increased throughout the 30-second SLS test for the HAT tear group, with 57% of HAT tear patients demonstrating a positive Trendelenburg sign. POF angle during the test was not significantly associated with pain. Conclusion Patients with symptomatic HAT tears demonstrate poor function, and report pain and disability similar to or worse than those with end-stage hip OA. This information better defines and differentiates the presentation of these patients. Level of Evidence Level 3 case-controlled study, with matched comparison PMID:27757285

  12. Anti-HIV drugs nevirapine and efavirenz affect anxiety-related behavior and cognitive performance in mice.

    PubMed

    Romão, Pedro R T; Lemos, Joelson C; Moreira, Jeverson; de Chaves, Gisele; Moretti, Morgana; Castro, Adalberto A; Andrade, Vanessa M; Boeck, Carina R; Quevedo, João; Gavioli, Elaine C

    2011-01-01

    Nevirapine (NVP) and efavirenz (EFV) belong to the class of anti-HIV drugs called non-nucleoside reverse transcriptase inhibitors (NNRTIs), commonly used as part of highly active antiretroviral therapy (HAART). Although the HAART is able to bring down viral load to undetectable levels and restore immune function, their prolonged use causes several adverse effects. It has been demonstrated that both NVP and EFV are able to cross the blood-brain barrier, causing important central nervous system-related side effects. Thus, this study investigated the effects of chronic administration of EFV (10 mg/kg) and NVP (3.3 mg/kg) in mice submitted to two distinct series of experiments, which aimed to evaluate: (1) the emotional behavior (elevated plus-maze, forced swimming, and open-field test) and (2) the cognitive performance (object recognition and inhibitory avoidance test) of mice. Our results demonstrated that EFV, but not NVP, reduced the exploration to open arms in the elevated plus-maze test. Neither NVP nor EFV altered mouse behavior in the forced swimming and open-field tests. Both drugs reduced the recognition index in the object recognition test, but only EFV significantly impaired the aversive memory assessed in the inhibitory avoidance test 24 h after training. In conclusion, our findings point to a genuine anxiogenic-like effect to EFV, since it reduced exploration to open arms of elevated plus-maze test without affecting spontaneous locomotion. Additionally, both drugs impaired recognition memory, while only the treatment with EFV impaired significantly aversive memory.

  13. Negatively-marked MCQ assessments that reward partial knowledge do not introduce gender bias yet increase student performance and satisfaction and reduce anxiety.

    PubMed

    Bond, A Elizabeth; Bodger, Owen; Skibinski, David O F; Jones, D Hugh; Restall, Colin J; Dudley, Edward; van Keulen, Geertje

    2013-01-01

    Multiple-choice question (MCQ) examinations are increasingly used as the assessment method of theoretical knowledge in large class-size modules in many life science degrees. MCQ-tests can be used to objectively measure factual knowledge, ability and high-level learning outcomes, but may also introduce gender bias in performance dependent on topic, instruction, scoring and difficulty. The 'Single Answer' (SA) test is often used in which students choose one correct answer, in which they are unable to demonstrate partial knowledge. Negatively marking eliminates the chance element of guessing but may be considered unfair. Elimination testing (ET) is an alternative form of MCQ, which discriminates between all levels of knowledge, while rewarding demonstration of partial knowledge. Comparisons of performance and gender bias in negatively marked SA and ET tests have not yet been performed in the life sciences. Our results show that life science students were significantly advantaged by answering the MCQ test in elimination format compared to single answer format under negative marking conditions by rewarding partial knowledge of topics. Importantly, we found no significant difference in performance between genders in either cohort for either MCQ test under negative marking conditions. Surveys showed that students generally preferred ET-style MCQ testing over SA-style testing. Students reported feeling more relaxed taking ET MCQ and more stressed when sitting SA tests, while disagreeing with being distracted by thinking about best tactics for scoring high. Students agreed ET testing improved their critical thinking skills. We conclude that appropriately-designed MCQ tests do not systematically discriminate between genders. We recommend careful consideration in choosing the type of MCQ test, and propose to apply negative scoring conditions to each test type to avoid the introduction of gender bias. The student experience could be improved through the incorporation of the elimination answering methods in MCQ tests via rewarding partial and full knowledge.

  14. Negatively-Marked MCQ Assessments That Reward Partial Knowledge Do Not Introduce Gender Bias Yet Increase Student Performance and Satisfaction and Reduce Anxiety

    PubMed Central

    Bond, A. Elizabeth; Bodger, Owen; Skibinski, David O. F.; Jones, D. Hugh; Restall, Colin J.; Dudley, Edward; van Keulen, Geertje

    2013-01-01

    Multiple-choice question (MCQ) examinations are increasingly used as the assessment method of theoretical knowledge in large class-size modules in many life science degrees. MCQ-tests can be used to objectively measure factual knowledge, ability and high-level learning outcomes, but may also introduce gender bias in performance dependent on topic, instruction, scoring and difficulty. The ‘Single Answer’ (SA) test is often used in which students choose one correct answer, in which they are unable to demonstrate partial knowledge. Negatively marking eliminates the chance element of guessing but may be considered unfair. Elimination testing (ET) is an alternative form of MCQ, which discriminates between all levels of knowledge, while rewarding demonstration of partial knowledge. Comparisons of performance and gender bias in negatively marked SA and ET tests have not yet been performed in the life sciences. Our results show that life science students were significantly advantaged by answering the MCQ test in elimination format compared to single answer format under negative marking conditions by rewarding partial knowledge of topics. Importantly, we found no significant difference in performance between genders in either cohort for either MCQ test under negative marking conditions. Surveys showed that students generally preferred ET-style MCQ testing over SA-style testing. Students reported feeling more relaxed taking ET MCQ and more stressed when sitting SA tests, while disagreeing with being distracted by thinking about best tactics for scoring high. Students agreed ET testing improved their critical thinking skills. We conclude that appropriately-designed MCQ tests do not systematically discriminate between genders. We recommend careful consideration in choosing the type of MCQ test, and propose to apply negative scoring conditions to each test type to avoid the introduction of gender bias. The student experience could be improved through the incorporation of the elimination answering methods in MCQ tests via rewarding partial and full knowledge. PMID:23437081

  15. Comprehensive proficiency-based inanimate training for robotic surgery: reliability, feasibility, and educational benefit.

    PubMed

    Arain, Nabeel A; Dulan, Genevieve; Hogg, Deborah C; Rege, Robert V; Powers, Cathryn E; Tesfay, Seifu T; Hynan, Linda S; Scott, Daniel J

    2012-10-01

    We previously developed a comprehensive proficiency-based robotic training curriculum demonstrating construct, content, and face validity. This study aimed to assess reliability, feasibility, and educational benefit associated with curricular implementation. Over an 11-month period, 55 residents, fellows, and faculty (robotic novices) from general surgery, urology, and gynecology were enrolled in a 2-month curriculum: online didactics, half-day hands-on tutorial, and self-practice using nine inanimate exercises. Each trainee completed a questionnaire and performed a single proctored repetition of each task before (pretest) and after (post-test) training. Tasks were scored for time and errors using modified FLS metrics. For inter-rater reliability (IRR), three trainees were scored by two raters and analyzed using intraclass correlation coefficients (ICC). Data from eight experts were analyzed using ICC and Cronbach's α to determine test-retest reliability and internal consistency, respectively. Educational benefit was assessed by comparing baseline (pretest) and final (post-test) trainee performance; comparisons used Wilcoxon signed-rank test. Of the 55 trainees that pretested, 53 (96 %) completed all curricular components in 9-17 h and reached proficiency after completing an average of 72 ± 28 repetitions over 5 ± 1 h. Trainees indicated minimal prior robotic experience and "poor comfort" with robotic skills at baseline (1.8 ± 0.9) compared to final testing (3.1 ± 0.8, p < 0.001). IRR data for the composite score revealed an ICC of 0.96 (p < 0.001). Test-retest reliability was 0.91 (p < 0.001) and internal consistency was 0.81. Performance improved significantly after training for all nine tasks and according to composite scores (548 ± 176 vs. 914 ± 81, p < 0.001), demonstrating educational benefit. This curriculum is associated with high reliability measures, demonstrated feasibility for a large cohort of trainees, and yielded significant educational benefit. Further studies and adoption of this curriculum are encouraged.

  16. Demonstration of movement in the sacroiliac joint using ultrasound

    NASA Astrophysics Data System (ADS)

    Krupinski, Elizabeth A.; Brooks, William J.; Lund, Pamela J.

    1995-05-01

    The goal of this study was to demonstrate quantitatively, using ultrasound (US) recording techniques, the extent of motion of the sacroiliac joint achieved using manual medicine techniques. Initial judgements of perceived (i.e., felt) SI mobility during manual examination were made on 22 subjects. Baseline no movement ultrasound images (static) were obtained of the left and right SI joints at two levels-- posterior-superior-iliac-spine and inferior (PSIS, INF)--and two projections (AP and LAT). Manual medicine spring testing of the SI joint was then performed while ultrasound recordings (on video) were made. The differences between baseline separation of the SI joint and displacement distance during spring testing were measured by six radiologists who typically read US images. Significant movement of at least one SI joint was demonstrated in 91% of the subjects using ultrasound recordings. The extent of movement appeared to corroborate the experience of manual medicine practitioners.

  17. Concentrating Solar Power Central Receiver Panel Component Fabrication and Testing FINAL REPORT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McDowell, Michael W; Miner, Kris

    The objective of this project is to complete a design of an advanced concentrated solar panel and demonstrate the manufacturability of key components. Then confirm the operation of the key components under prototypic solar flux conditions. This work is an important step in reducing the levelized cost of energy (LCOE) from a central receiver solar power plant. The key technical risk to building larger power towers is building the larger receiver systems. Therefore, this proposed technology project includes the design of an advanced molten salt prototypic sub-scale receiver panel that can be utilized into a large receiver system. Then completemore » the fabrication and testing of key components of the receive design that will be used to validate the design. This project shall have a significant impact on solar thermal power plant design. Receiver panels of suitable size for utility scale plants are a key element to a solar power tower plant. Many subtle and complex manufacturing processes are involved in producing a reliable, robust receiver panel. Given the substantial size difference between receiver panels manufactured in the past and those needed for large plant designs, the manufacture and demonstration on prototype receiver panel components with representative features of a full-sized panel will be important to improving the build process for commercial success. Given the thermal flux limitations of the test facility, the panel components cannot be rendered full size. Significance changes occurred in the projects technical strategies from project initiation to the accomplishments described herein. The initial strategy was to define cost improvements for the receiver, design and build a scale prototype receiver and test, on sun, with a molten salt heat transport system. DOE had committed to constructing a molten salt heat transport loop to support receiver testing at the top of the NSTTF tower. Because of funding constraints this did not happen. A subsequent plan to test scale prototype receiver, off sun but at temperature, at a molten salt loop at ground level adjacent to the tower also had to be abandoned. Thus, no test facility existed for a molten salt receiver test. As a result, PWR completed the prototype receiver design and then fabricated key components for testing instead of fabricating the complete prototype receiver. A number of innovative design ideas have been developed. Key features of the receiver panel have been identified. This evaluation includes input from Solar 2, personal experience of people working on these programs and meetings with Sandia. Key components of the receiver design and key processes used to fabricate a receiver have been selected for further evaluation. The Test Plan, Concentrated Solar Power Receiver In Cooperation with the Department of Energy and Sandia National Laboratory was written to define the scope of the testing to be completed as well as to provide details related to the hardware, instrumentation, and data acquisition. The document contains a list of test objectives, a test matrix, and an associated test box showing the operating points to be tested. Test Objectives: 1. Demonstrate low-cost manufacturability 2. Demonstrate robustness of two different tube base materials 3. Collect temperature data during on sun operation 4. Demonstrate long term repeated daily operation of heat shields 5. Complete pinhole tube weld repairs 6. Anchor thermal models This report discusses the tests performed, the results, and implications for design improvements and LCOE reduction.« less

  18. Development of an unlicensed assistive personnel job screening test.

    PubMed

    Newhouse, Robin P; Steinhauser, Michele; Berk, Ron

    2007-01-01

    Unlicensed assistive personnel (UAP) competency is essential to the quality and safety of patient care. The purpose of this study was to construct a test with acceptable estimates of reliability and validity to identify UAPs who could successfully perform their job in four essential knowledge-based domains (math, patient data collection, medical terminology, and reporting abnormal data). An investigator-developed test was constructed. Psychometric testing was completed by administering the test to 145 UAPs. A cut score of 17/23 resulted in 79.7% sensitivity and 70.4% specificity. There were significant differences in mean scores between masters and nonmasters (t = -13.70, df = 79, p < .00). Master status was significantly related to the ability to take a patient's blood pressure (Phi = .503, p < .00). A score of 17 or greater indicates that the applicant demonstrates competency of basic knowledge required for the position. The test can be used as a screening tool for UAPs in nurse recruitment before candidates advance to the unit for an interview.

  19. Wind tunnel test of a variable-diameter tiltrotor (VDTR) model

    NASA Technical Reports Server (NTRS)

    Matuska, David; Dale, Allen; Lorber, Peter

    1994-01-01

    This report documents the results from a wind tunnel test of a 1/6th scale Variable Diameter Tiltrotor (VDTR). This test was a joint effort of NASA Ames and Sikorsky Aircraft. The objective was to evaluate the aeroelastic and performance characteristics of the VDTR in conversion, hover, and cruise. The rotor diameter and nacelle angle of the model were remotely changed to represent tiltrotor operating conditions. Data is presented showing the propulsive force required in conversion, blade loads, angle of attack stability and simulated gust response, and hover and cruise performance. This test represents the first wind tunnel test of a variable diameter rotor applied to a tiltrotor concept. The results confirm some of the potential advantages of the VDTR and establish the variable diameter rotor a viable candidate for an advanced tiltrotor. This wind tunnel test successfully demonstrated the feasibility of the Variable Diameter rotor for tilt rotor aircraft. A wide range of test points were taken in hover, conversion, and cruise modes. The concept was shown to have a number of advantages over conventional tiltrotors such as reduced hover downwash with lower disk loading and significantly reduced longitudinal gust response in cruise. In the conversion regime, a high propulsive force was demonstrated for sustained flight with acceptable blade loads. The VDTR demonstrated excellent gust response capabilities. The horizontal gust response correlated well with predictions revealing only half the response to turbulence of the conventional civil tiltrotor.

  20. Final payload test results for the RemoveDebris active debris removal mission

    NASA Astrophysics Data System (ADS)

    Forshaw, Jason L.; Aglietti, Guglielmo S.; Salmon, Thierry; Retat, Ingo; Roe, Mark; Burgess, Christopher; Chabot, Thomas; Pisseloup, Aurélien; Phipps, Andy; Bernal, Cesar; Chaumette, François; Pollini, Alexandre; Steyn, Willem H.

    2017-09-01

    Since the beginning of the space era, a significant amount of debris has progressively been generated in space. Active Debris Removal (ADR) missions have been suggested as a way of limiting and controlling future growth in orbital space debris by actively deploying vehicles to remove debris. The European Commission FP7-sponsored RemoveDebris mission, which started in 2013, draws on the expertise of some of Europe's most prominent space institutions in order to demonstrate key ADR technologies in a cost effective ambitious manner: net capture, harpoon capture, vision-based navigation, dragsail de-orbiting. This paper provides an overview of some of the final payload test results before launch. A comprehensive test campaign is underway on both payloads and platform. The tests aim to demonstrate both functional success of the experiments and that the experiments can survive the space environment. Space environmental tests (EVT) include vibration, thermal, vacuum or thermal-vacuum (TVAC) and in some cases EMC and shock. The test flow differs for each payload and depends on the heritage of the constituent payload parts. The paper will also provide an update to the launch, expected in 2017 from the International Space Station (ISS), and test philosophy that has been influenced from the launch and prerequisite NASA safety review for the mission. The RemoveDebris mission aims to be one of the world's first in-orbit demonstrations of key technologies for active debris removal and is a vital prerequisite to achieving the ultimate goal of a cleaner Earth orbital environment.

  1. The effect of thermocycling on the fracture toughness and hardness of core buildup materials.

    PubMed

    Medina Tirado, J I; Nagy, W W; Dhuru, V B; Ziebert, A J

    2001-11-01

    Thermocycling has been shown to cause surface degradation of many dental materials, but its effect on the fracture toughness and hardness of direct core buildup materials is unknown. This study was designed to determine the effect of thermocycling on the fracture toughness and hardness of 5 core buildup materials. Fifteen specimens were prepared from each of the following materials: Fluorocore, VariGlass VLC, Valiant PhD, Vitremer, and Chelon-Silver. American Standard for Testing Materials guidelines for single-edge notch, bar-shaped specimens were used. Ten specimens of each material were thermocycled for 2000 cycles; the other 5 specimens were not thermocycled. All specimens were subjected to 3-point bending in a universal testing machine. The load at fracture was recorded, and the fracture toughness (K(IC)) was calculated. Barcol hardness values were also determined. Data were analyzed with 1-way analysis of variance and compared with the Tukey multiple range test (P<.05). Pearson's correlation coefficient was also calculated to measure the association between fracture toughness and hardness. Fluorocore had the highest thermocycled mean K(IC) and Valiant PhD the highest non-thermocycled K(IC). Chelon-Silver demonstrated the lowest mean K(IC) both before and after thermocycling. One-way analysis of variance demonstrated significant differences between conditions, and the Tukey test showed significant differences (P<.05) between materials for both conditions. Most specimens also showed significant hardness differences between conditions. Pearson's correlation coefficient indicated only a mild-to-moderate correlation between hardness and fracture toughness. Within the limitations of this study, the thermocycling process negatively affected the fracture toughness and hardness of the core buildup materials tested.

  2. The Langley Wind Tunnel Enterprise

    NASA Technical Reports Server (NTRS)

    Paulson, John W., Jr.; Kumar, Ajay; Kegelman, Jerome T.

    1998-01-01

    After 4 years of existence, the Langley WTE is alive and growing. Significant improvements in the operation of wind tunnels have been demonstrated and substantial further improvements are expected when we are able to truly address and integrate all the processes affecting the wind tunnel testing cycle.

  3. PubMed Central

    CARLI, P.; PATRIZI, M.; PEPE, L.; CAVANIGLIA, G.; RIVA, D.; D’OTTAVI, L.R.

    2010-01-01

    SUMMARY Nine healthy volunteers (6 males, 3 females), mean age 34.5 years (SD = 11.52), underwent a vestibulo-postural rehabilitation cycle with a visuo-proprioceptive-type stimulus. All subjects in the study group were evaluated by means of stabilometric bipodalic and monopodalic tests both before and immediately after treatment, and again 3 month thereafter. The Delos Postural Proprioceptive System®, DPPS (Delos, srl, Turin, Italy), was used in performing these stabilometric tests and in the rehabilitation exercises. The first aim of the study was to evaluate to what extent the functional level of the proprioceptive system was reliable, in healthy subjects, in the control of postural stability; the second was to demonstrate the possibility to increase this level by means of a novel visuo-proprioceptive feedback training; the last was to establish whether or not the increase achieved was permanent. The bipodalic test did not reveal any deficit in posture either before or after rehabilitation. The monopodalic test prior to treatment, with eyes closed, revealed, in 2/3 of the study group, evidence of the risk of falling, expressed as the precautional strategy (8.57 ± 6.18% SD). An increase in the proprioceptive activity, obtained in the subjects examined immediately after the visuo-proprioceptive vestibulo-postural rehabilitation, led, in the monopodalic test, with eyes closed, to a significant reduction in the risk of falling (with the precautional strategy equal to 1.09 ± 2.63% SD, p = 0.004). The monopodalic test, with eyes closed, 3 months after rehabilitation, demonstrated results not unlike those pre-treament with values, therefore, not more significant than those emerging from the pre-treatment test. Thus, from the above-mentioned data, it can be observed that, also in healthy subjects, there may be different levels of postural proprioceptive control related to a high risk of falling. These levels can be maintained constant for a certain period of time, until a significant reduction in the risk of falling is achieved, only if continuously stimulated by appropriate sensorial information. PMID:21253283

  4. Cardiovascular responses of men and women to lower body negative pressure

    NASA Technical Reports Server (NTRS)

    Montgomery, L. D.; Kirk, P. J.; Payne, P. A.; Gerber, R. L.; Newton, S. D.; Williams, B. A.

    1977-01-01

    Changes in blood flow and blood redistribution were measured by impedance plethysmography in the pelvic and leg regions of six male and four female subjects during three 5-min exposures to -20, -40, and -60 mm Hg lower body negative pressure (LBNP). Female subjects demonstrated significantly higher mean heart rate and lower leg blood flow indices than the male subjects during the recumbent control periods. Men had slightly higher mean resting systolic and diastolic blood pressures and higher mean control pelvic blood indices. Women demonstrated significantly less blood pooling in the legs and slightly less in the pelvic region than the men. All of the 18 tests with male subjects at -60 mm Hg were completed without initial signs of syncope, while only two of the tests with women were completed successfully without the subject exhibiting presyncopal conditions. Results indicate that impedance plethysmography can be used to measure segmental cardiovascular responses during LBNP and that females may be less tolerant to -60 mm Hg LBNP than males.

  5. Diabetes Mellitus Alters the Mechanical Properties of the Native Tendon in an Experimental Rat Model

    PubMed Central

    Fox, Alice J. S.; Bedi, Asheesh; Deng, Xiang-Hua; Ying, Liang; Harris, Paul E.; Warren, Russell F.; Rodeo, Scott A.

    2017-01-01

    The purpose of this study was to determine the effect of the diabetic phenotype on the mechanical properties of the native patellar tendon and its enthesis. Diabetes was induced via intraperitoneal injection of streptozotocin in Lewis rats. Control (n = 18) and diabetic animals(n = 20) were killed at 12 and 19 days for analysis. Statistical comparisons were performed using Student’s t-tests and a two-tailed Fisher test with significance set at p < 0.05. Pre- and post-injection intraperitoneal glucose tolerance tests demonstrated significant impairment of glycemic control in the diabetic compared to control animals (p = 0.001). Mean serum hemoglobin A1c levels at 19 days was 10.6 ± 2.7% and 6.0 ± 1.0% for the diabetic and control groups, respectively (p = 0.0001). Fifteen of sixteen diabetic animals demonstrated intrasubstance failure of the patellar tendon, while only 7 of 14 control specimens failed within the tendon substance. The Young’s modulus of the diabetic tendon was significantly lower than control specimens by 19 days post-induction (161 ± 10 N m−2 compared to 200 ± 46 N m−2, respectively) (p = 0.02). The metabolic condition of poorly controlled diabetes negatively affects the mechanical properties of the native patellar tendon. These altered structural properties may predispose diabetic patients to a greater risk of tendinopathy and/or traumatic rupture. PMID:21246619

  6. Testing statistical self-similarity in the topology of river networks

    USGS Publications Warehouse

    Troutman, Brent M.; Mantilla, Ricardo; Gupta, Vijay K.

    2010-01-01

    Recent work has demonstrated that the topological properties of real river networks deviate significantly from predictions of Shreve's random model. At the same time the property of mean self-similarity postulated by Tokunaga's model is well supported by data. Recently, a new class of network model called random self-similar networks (RSN) that combines self-similarity and randomness has been introduced to replicate important topological features observed in real river networks. We investigate if the hypothesis of statistical self-similarity in the RSN model is supported by data on a set of 30 basins located across the continental United States that encompass a wide range of hydroclimatic variability. We demonstrate that the generators of the RSN model obey a geometric distribution, and self-similarity holds in a statistical sense in 26 of these 30 basins. The parameters describing the distribution of interior and exterior generators are tested to be statistically different and the difference is shown to produce the well-known Hack's law. The inter-basin variability of RSN parameters is found to be statistically significant. We also test generator dependence on two climatic indices, mean annual precipitation and radiative index of dryness. Some indication of climatic influence on the generators is detected, but this influence is not statistically significant with the sample size available. Finally, two key applications of the RSN model to hydrology and geomorphology are briefly discussed.

  7. Fundamental movement skills in adolescents: Secular trends from 2003 to 2010 and associations with physical activity and BMI.

    PubMed

    Huotari, P; Heikinaro-Johansson, P; Watt, A; Jaakkola, T

    2018-03-01

    The aim of this study was to examine the secular trends in fundamental movement skills (FMS) among 15- to 16-year-old adolescents at 2 assessment points scheduled in 2003 and 2010 and to investigate the associations between FMS, physical activity (PA), and body mass index (BMI). In 2003, self-reported PA, weight and height, and objective FMS scores were collected from 2390 students, and in 2010, similar data were generated from a second sample of 1346 students. FMS were assessed during both assessment phases using 3 identical objective FMS tests that were figure 8 dribbling, jumping laterally, and coordination track tests. This study indicated that the sum index of FMS did not change among the boys and the girls between 2 data collection points. However, findings demonstrated a secular decline in coordination test scores in both gender groups between 2 measurement points but an improvement in girls' object control skills between 2003 and 2010. The results also showed that FMS had a significant main effect on BMI in both gender groups, whereas the main effect of PA on BMI was not significant for either gender group. Results also demonstrated that there was no significant interaction effect between FMS and PA on BMI in either of the girls' or the boys' groups. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Numerical analysis for infant's unintentional exposure to 3.5 GHz plane wave radiofrequency electromagnetic fields by field test of fifth generation wireless technologies

    NASA Astrophysics Data System (ADS)

    Liu, Dan; Li, Congsheng; Kang, Yangyang; Zhou, Zhou; Xie, Yi; Wu, Tongning

    2017-09-01

    In this study, the plane wave exposure of an infant to radiofrequency electromagnetic fields of 3.5 GHz was numerically analyzed to investigate the unintentional electromagnetic field (EMF) exposure of fifth generation (5G) signals during field test. The dosimetric influence of age-dependent dielectric properties and the influence of an adult body were evaluated using an infant model of 12 month old and an adult female model. The results demonstrated that the whole body-averaged specific absorption rate (WBASAR) was not significantly affected by age-dependent dielectric properties and the influence of the adult body did not enhance WBASAR. Taking the magnitude of the in situ E field strength into consideration, realistic WBASAR was far below the basic restriction. Age-dependent dielectric properties could significantly change the tissue specified specific absorption rate (TSSAR) of internal organs. However, the variation was not significant because the absolute values were marginal. Among the factors that influenced TSSAR variation, change in dielectric properties demonstrated a close correlation. In general, at 3.5 GHz, the infant did not absorb more power than the case of EMF exposure to third generation (3G) and fourth generation (4G) signals. The work was helpful for network operators and device manufactures to estimate the potential exposure risk during the field test, especially for the infant.

  9. Development and Lab-Scale Testing of a Gas Generator Hybrid Fuel in Support of the Hydrogen Peroxide Hybrid Upper Stage Program

    NASA Technical Reports Server (NTRS)

    Lund, Gary K.; Starrett, William David; Jensen, Kent C.; McNeal, Curtis (Technical Monitor)

    2001-01-01

    As part of a NASA funded contract to develop and demonstrate a gas generator cycle hybrid rocket motor for upper stage space motor applications, the development and demonstration of a low sensitivity, high performance fuel composition was undertaken. The ultimate goal of the development program was to demonstrate successful hybrid operation (start, stop, throttling) of the fuel with high concentration (90+%) hydrogen peroxide. The formulation development and lab-scale testing of a simple DOT Class 1.4c gas generator propellant is described. Both forward injected center perforated and aft injected end burner hybrid combustion behavior were evaluated with gaseous oxygen and catalytically decomposed 90% hydrogen peroxide. Cross flow and static environments were found to yield profoundly different combustion behaviors, which were further governed by binder type, oxidizer level and, significantly, oxidizer particle size. Primary extinguishment was accomplished via manipulation of PDL behavior and oxidizer turndown, which is enhanced with the hydrogen peroxide system. Laboratory scale combustor results compared very well with 11-inch and 24-inch sub-scale test results with 90% hydrogen peroxide.

  10. Chemically Attenuated Blood-Stage Plasmodium yoelii Parasites Induce Long-Lived and Strain-Transcending Protection

    PubMed Central

    Raja, Amber I.; Cai, Yeping; Reiman, Jennifer M.; Groves, Penny; Chakravarty, Sumana; McPhun, Virginia; Doolan, Denise L.; Cockburn, Ian; Hoffman, Stephen L.; Stanisic, Danielle I.

    2016-01-01

    The development of a vaccine is essential for the elimination of malaria. However, despite many years of effort, a successful vaccine has not been achieved. Most subunit vaccine candidates tested in clinical trials have provided limited efficacy, and thus attenuated whole-parasite vaccines are now receiving close scrutiny. Here, we test chemically attenuated Plasmodium yoelii 17X and demonstrate significant protection following homologous and heterologous blood-stage challenge. Protection against blood-stage infection persisted for at least 9 months. Activation of both CD4+ and CD8+ T cells was shown after vaccination; however, in vivo studies demonstrated a pivotal role for both CD4+ T cells and B cells since the absence of either cell type led to loss of vaccine-induced protection. In spite of significant activation of circulating CD8+ T cells, liver-stage immunity was not evident. Neither did vaccine-induced CD8+ T cells contribute to blood-stage protection; rather, these cells contributed to pathogenesis, since all vaccinated mice depleted of both CD4+ and CD8+ T cells survived a challenge infection. This study provides critical insight into whole-parasite vaccine-induced immunity and strong support for testing whole-parasite vaccines in humans. PMID:27245410

  11. Evaluating the Thermal Damage Resistance of Reduced Graphene Oxide/Carbon Nanotube Hybrid Coatings

    NASA Astrophysics Data System (ADS)

    David, Lamuel; Feldman, Ari; Mansfield, Elisabeth; Lehman, John; Singh, Gurpreet; National Institute of Standards and Technology Collaboration

    2014-03-01

    Carbon nanotubes and graphene are known to exhibit some exceptional thermal (K ~ 2000 to 4400 W.m-1K-1 at 300K) and optical properties. Here, we demonstrate preparation and testing of multiwalled carbon nanotubes and chemically modified graphene-composite spray coatings for use on thermal detectors for high-power lasers. The synthesized nanocomposite material was tested by preparing spray coatings on aluminum test coupons used as a representation of the thermal detector's surface. These coatings were then exposed to increasing laser powers and extended exposure times to quantify their damage threshold and optical absorbance. The graphene/carbon nanotube (prepared at varying mass% of graphene in CNTs) coatings demonstrated significantly higher damage threshold values at 2.5 kW laser power (10.6 μm wavelength) than carbon paint or MWCNTs alone. Electron microscopy and Raman spectroscopy of irradiated specimens showed that the composite coating endured high laser-power densities (up to 2 kW.cm-2) without significant visual damage. This research is based on work supported by the National Science Foundation (Chemical, Bioengineering, Environmental, and Transport Systems Division), under grant no. 1335862 to G. Singh.

  12. Suitport Feasibility - Development and Test of a Suitport and Space Suit for Human Pressurized Space Suit Donning Tests

    NASA Technical Reports Server (NTRS)

    Boyle, Robert M.; Mitchell, Kathryn; Allton, Charles; Ju, Hsing

    2011-01-01

    The suitport concept has been recently implemented as part of the small pressurized lunar rover (Currently the Space Exploration vehicle, or SEV) and the Multi-Mission Space Exploration Vehicle (MMSEV) concept demonstrator vehicle. Suitport replaces or augments the traditional airlock function of a spacecraft by providing a bulkhead opening, capture mechanism, and sealing system to allow ingress and egress of a spacesuit while the spacesuit remains outside of the pressurized volume of the spacecraft. This presents significant new opportunities to EVA exploration in both microgravity and surface environments. The suitport concept will enable three main improvements in EVA by providing reductions in: pre-EVA time from hours to less than thirty minutes; airlock consumables; contamination returned to the cabin with the EVA crewmember. To date, the first generation suitport has been tested with mockup suits on the rover cabins and pressurized on a bench top engineering unit. The work on the rover cabin has helped define the operational concepts and timelines, and has demonstrated the potential of suitport to save significant amounts of crew time before and after EVAs. The work with the engineering unit has successfully demonstrated the pressurizable seal concept including the ability to seal after the introduction and removal of contamination to the sealing surfaces. Using this experience, a second generation suitport was designed. This second generation suitport has been tested with a spacesuit prototype using the pressure differentials of the spacecraft. This test will be performed using the JSC B32 Chamber B, a human rated vacuum chamber. This test will include human rated suitports, the suitport compatible prototype suit, and chamber modifications. This test will bring these three elements together in the first ever pressurized donning of a rear entry suit through a suitport. This paper presents design of a human rated second generation suitport, modifications to the JSC human rated chamber B to accept a suitport, and a compatible space suit to support pressurized human donning of the pressurized suit through a suitport. Design challenges and solutions and compromises required to develop the system are presented. Initial human testing results are presented.

  13. Test anxiety and academic performance in chiropractic students.

    PubMed

    Zhang, Niu; Henderson, Charles N R

    2014-01-01

    Objective : We assessed the level of students' test anxiety, and the relationship between test anxiety and academic performance. Methods : We recruited 166 third-quarter students. The Test Anxiety Inventory (TAI) was administered to all participants. Total scores from written examinations and objective structured clinical examinations (OSCEs) were used as response variables. Results : Multiple regression analysis shows that there was a modest, but statistically significant negative correlation between TAI scores and written exam scores, but not OSCE scores. Worry and emotionality were the best predictive models for written exam scores. Mean total anxiety and emotionality scores for females were significantly higher than those for males, but not worry scores. Conclusion : Moderate-to-high test anxiety was observed in 85% of the chiropractic students examined. However, total test anxiety, as measured by the TAI score, was a very weak predictive model for written exam performance. Multiple regression analysis demonstrated that replacing total anxiety (TAI) with worry and emotionality (TAI subscales) produces a much more effective predictive model of written exam performance. Sex, age, highest current academic degree, and ethnicity contributed little additional predictive power in either regression model. Moreover, TAI scores were not found to be statistically significant predictors of physical exam skill performance, as measured by OSCEs.

  14. Use of adaptive walls in 2D tests

    NASA Technical Reports Server (NTRS)

    Archambaud, J. P.; Chevallier, J. P.

    1984-01-01

    A new method for computing the wall effects gives precise answers to some questions arising in adaptive wall concept applications: length of adapted regions, fairings with up and downstream regions, residual misadjustments effects, reference conditions. The acceleration of the iterative process convergence and the development of an efficient technology used in CERT T2 wind tunnels give in a single run the required test conditions. Samples taken from CAST 7 tests demonstrate the efficiency of the whole process to obtain significant results with considerations of tridimensional case extension.

  15. JT8D-15/17 High Pressure Turbine Root Discharged Blade Performance Improvement. [engine design

    NASA Technical Reports Server (NTRS)

    Janus, A. S.

    1981-01-01

    The JT8D high pressure turbine blade and seal were modified, using a more efficient blade cooling system, improved airfoil aerodynamics, more effective control of secondary flows, and improved blade tip sealing. Engine testing was conducted to determine the effect of these improvements on performance. The modified turbine package demonstrated significant thrust specific fuel consumption and exhaust gas temperature improvements in sea level and altitude engine tests. Inspection of the improved blade and seal hardware after testing revealed no unusual wear or degradation.

  16. Cryogenic nitrogen as a transonic wind-tunnel test gas

    NASA Technical Reports Server (NTRS)

    Adcock, J. B.; Kilgore, R. A.; Ray, E. J.

    1975-01-01

    The test gas for the Langley Pilot Transonic Cryogenic Tunnel is nitrogen. Results from analytical and experimental studies that have verified cryogenic nitrogen as an acceptable test gas are reviewed. Real-gas isentropic and normal-shock flow solutions for nitrogen are compared to the ideal diatomic gas solutions. Experimental data demonstrate that for temperatures above the liquefaction boundaries there are no significant real-gas effects on two-dimensional airfoil pressure distributions. Results of studies to determine the minimum operating temperatures while avoiding appreciable effects due to liquefaction are included.

  17. Enzymatic recontouring of auricular cartilage in a rabbit model.

    PubMed

    Massengill, Phillip L; Goco, Paulino E; Norlund, L Layne; Muir-Padilla, Jeanne

    2005-01-01

    To evaluate the effectiveness of contouring auricular cartilage in a rabbit model using biologically active enzymes injected subcutaneously. The first phase determined the most effective volume and concentration required to affect the cartilage. To accomplish this task, we used ex vivo rabbit ears from a slaughterhouse. In the second phase, we injected 1 mL of hyaluronidase (150 U per milliliter of isotonic sodium chloride solution [saline]), elastase (1 mg per milliliter of saline), or saline into the ears of live rabbits. The study took place at the Madigan Army Medical Center (Tacoma, Wash), and included 10 animals. In each rabbit, we injected the test compound in one ear and saline in the other ear (control). We injected hyaluronidase in 5 ears and elastase in 5 ears. After injection, the ears were contoured and splinted for 4 weeks. In the third phase, we changed the injection pathway in 5 animals. At 4 weeks, 4 (80%) of the 5 ears injected with hyaluronidase showed full response and 1 (20%) had a partial response. Of the 5 ears injected with elastase, 4 (80%) showed a full response while 1 (20%) demonstrated a partial response. There was a response in all 10 of the ears injected with a test compound. Of the 10 control ears, 3 (30%) showed a partial response. At 6 weeks, approximately 6 (30%) of the ears had maintained contour demonstrating a full response. The difference between the test ears and the control ears was statistically significant (P = .006). Compared with the control ears, the results were statistically significant for elastase (P = .004) and hyaluronidase (P = .02). Overall, both agents demonstrated a subjective and objective response compared with control ears. This study demonstrates that bioactive enzymes and splinting can be effective in correcting ear deformities in a rabbit model.

  18. Antinociceptive and anticonvulsant effects of the monoterpene linalool oxide.

    PubMed

    Souto-Maior, Flávia Negromonte; Fonsêca, Diogo Vilar da; Salgado, Paula Regina Rodrigues; Monte, Lucas de Oliveira; de Sousa, Damião Pergentino; de Almeida, Reinaldo Nóbrega

    2017-12-01

    Linalool oxide (OXL) (a monoterpene) is found in the essential oils of certain aromatic plants, or it is derived from linalool. The motivation for this work is the lack of psychopharmacological studies on this substance. To evaluate OXL's acute toxicity, along with its anticonvulsant and antinociceptive activities in male Swiss mice. OXL (50, 100 and 150 mg/kg, i.p.) was investigated for acute toxicity and in the Rota-rod test. Antinociceptive activity was evaluated by the acetic acid-induced writhing test, and by formalin testing. Anticonvulsant effects were demonstrated by testing for pentylenetetrazol (PTZ)-induced seizures and by Maximum Electroshock headset (MES) test. OXL was administered to the animals intraperitoneally 30 min before for pharmacological tests. OXL showed an LD 50 of ∼721 (681-765) mg/kg. In the Rota-rod test, it was observed that OXL caused no damage to the animal's motor coordination. OXL significantly reduced (p < .001) the number of writhings. OXL also significantly decreased (p < .05, p < .01 or p < .001) paw-licking time in the two phases of the formalin test. OXL significantly reduced (p < .01 or p < .001) the duration of tonic seizures in the MES test, and at the dose 150 mg/kg, significantly increased (p < .01) the latency to first seizure in the PTZ test. The tested doses of OXL were safe, with no motor impairment, and show clear antinociceptive and anticonvulsant potential. Future investigations with this monoterpene may lead to the development of a new molecule with even higher potency and selectivity.

  19. Are medical students being taught anatomy in a way that best prepares them to be a physician?

    PubMed

    Meral Savran, Mona; Tranum-Jensen, Jørgen; Frost Clementsen, Paul; Hastrup Svendsen, Jesper; Holst Pedersen, Jesper; Seier Poulsen, Steen; Arendrup, Henrik; Konge, Lars

    2015-07-01

    Reasoning in a clinical context is an attribute of medical expertise. Clinical reasoning in medical school can be encouraged by teaching basic science with a clinical emphasis. The aim of this study was to investigate whether anatomy is being taught in a way that facilitates the development of clinical reasoning. Two multiple-choice tests on thoracic anatomy were developed using a modified Delphi approach with groups of four clinical consultants and four teachers, respectively, expressing their opinions about knowledge relevant to thoracic anatomy. Validity was assessed by administering the tests to clinical consultants, anatomy teachers, and pre-course medical students. Post-course medical students took both tests to explore the focus of the course, i.e., whether it facilitated clinical reasoning. The pre-course students scored significantly lower than the teachers and post-course students on both tests and lower than the consultants on the consultants' test (P < 0.001 for all comparisons). The teachers significantly outperformed the consultants (P = 0.03 on the consultants' test, P < 0.001 on the teachers' test) and the medical students (P < 0.001 on both tests). The post-course students scored significantly lower on the consultants' test (P = 0.001) and significantly higher on the teachers' test (P = 0.02) than the consultants. This study demonstrates poor performances by medical students on a test containing clinically relevant anatomy, implying that the teaching they have received has not encouraged clinical reasoning. © 2015 Wiley Periodicals, Inc.

  20. Activity of levofloxacin alone and in combination with a DnaK inhibitor against gram-negative rods, including levofloxacin-resistant strains.

    PubMed

    Credito, Kim; Lin, Gengrong; Koeth, Laura; Sturgess, Michael A; Appelbaum, Peter C

    2009-02-01

    Synergy time-kill testing of levofloxacin alone and in combination with CHP-105, a representative DnaK inhibitor, against 50 gram-negative rods demonstrated that 34 of the 50 strains tested showed significant synergy between levofloxacin and CHP-105 after 12 h and 24 h. Fourteen of these 34 organisms were quinolone resistant (levofloxacin MICs of > or =4 microg/ml).

  1. Activity of Levofloxacin Alone and in Combination with a DnaK Inhibitor against Gram-Negative Rods, Including Levofloxacin-Resistant Strains▿

    PubMed Central

    Credito, Kim; Lin, Gengrong; Koeth, Laura; Sturgess, Michael A.; Appelbaum, Peter C.

    2009-01-01

    Synergy time-kill testing of levofloxacin alone and in combination with CHP-105, a representative DnaK inhibitor, against 50 gram-negative rods demonstrated that 34 of the 50 strains tested showed significant synergy between levofloxacin and CHP-105 after 12 h and 24 h. Fourteen of these 34 organisms were quinolone resistant (levofloxacin MICs of ≥4 μg/ml). PMID:19015359

  2. Development and Demonstration of Sustainable Surface Infrastructure for Moon/Mars Exploration

    NASA Technical Reports Server (NTRS)

    Sanders, Gerald B.; Larson, William E.; Picard, Martin

    2011-01-01

    For long-term human exploration of the Moon and Mars to be practical, affordable, and sustainable, future missions must be able to identify and utilize resources at the site of exploration. The ability to characterize, extract, processes, and separate products from local material, known as In-Situ Resource Utilization (ISRU), can provide significant reductions in launch mass, logistics, and development costs while reducing risk through increased mission flexibility and protection as well as increased mission capabilities in the areas of power and transportation. Making mission critical consumables like propellants, fuel cell reagents and life support gases, as well as in-situ crew/hardware protection and energy storage capabilities can significantly enhance robotic and human science and exploration missions, however other mission systems need to be designed to interface with and utilize these in-situ developed products and services from the start or the benefits will be minimized or eliminated. This requires a level of surface and transportation system development coordination not typically utilized during early technology and system development activities. An approach being utilized by the US National Aeronautics and Space Administration and the Canadian Space Agency has been to utilize joint analogue field demonstrations to focus technology development activities to demonstrate and integrate new and potentially game changing. mission critical capabilities that would enable an affordable and sustainable surface infrastructure for lunar and Mars robotic and human exploration. Two analogue field tests performed in November 2008 and February 2010 demonstrated first generation capabilities for lunar resource prospecting, exploration site preparation, and oxygen extraction from regolith while initiating integration with mobility, science, fuel cell power, and propulsion disciplines. A third analogue field test currently planned for June 2012 will continue and expand the fidelity and integration of these surface exploration and infrastructure capabilities while adding Mars exploration technologies, improving remote operations and control of hardware, and promoting the use of common software, interfaces, & standards for control and operation for surface exploration and science. The next field test will also attempt to include greater involvement by industry, academia, and other countries/space agencies. This paper will provide an overview of the development and demonstration approach utilized to date, the results of the previous two ISRU-focused field analogue tests in Hawaii, and the current objectives and plans for the 3rd international Hawaii analogue field test.

  3. Community-based group exercise for persons with Parkinson disease: a randomized controlled trial.

    PubMed

    Combs, Stephanie A; Diehl, M Dyer; Chrzastowski, Casey; Didrick, Nora; McCoin, Brittany; Mox, Nicholas; Staples, William H; Wayman, Jessica

    2013-01-01

    The purpose of this study was to compare group boxing training to traditional group exercise on function and quality of life in persons with Parkinson disease (PD). A convenience sample of adults with PD (n = 31) were randomly assigned to boxing training or traditional exercise for 24-36 sessions, each lasting 90 minutes, over 12 weeks. Boxing training included: stretching, boxing (e.g. lateral foot work, punching bags), resistance exercises, and aerobic training. Traditional exercise included: stretching, resistance exercises, aerobic training, and balance activities. Participants were tested before and after completion of training on balance, balance confidence, mobility, gait velocity, gait endurance, and quality of life. The traditional exercise group demonstrated significantly greater gains in balance confidence than the boxing group (p < 0.025). Only the boxing group demonstrated significant improvements in gait velocity and endurance over time with a medium between-group effect size for the gait endurance (d = 0.65). Both groups demonstrated significant improvements with the balance, mobility, and quality of life with large within-group effect sizes (d ≥ 0.80). While groups significantly differed in balance confidence after training, both groups demonstrated improvements in most outcome measures. Supporting options for long-term community-based group exercise for persons with PD will be an important future consideration for rehabilitation professionals.

  4. Association between kyphosis and subacromial impingement syndrome: LOHAS study.

    PubMed

    Otoshi, Kenichi; Takegami, Misa; Sekiguchi, Miho; Onishi, Yoshihiro; Yamazaki, Shin; Otani, Koji; Shishido, Hiroaki; Kikuchi, Shinichi; Konno, Shinichi

    2014-12-01

    Kyphosis is a cause of scapular dyskinesis, which can induce various shoulder disorders, including subacromial impingement syndrome (SIS). This study aimed to clarify the impact of kyphosis on SIS with use of cross-sectional data from the Locomotive Syndrome and Health Outcome in Aizu Cohort Study (LOHAS). The study enrolled 2144 participants who were older than 40 years and participated in health checkups in 2010. Kyphosis was assessed by the wall-occiput test (WOT) for thoracic kyphosis and the rib-pelvic distance test (RPDT) for lumbar kyphosis. The associations between kyphosis, SIS, and reduction in shoulder elevation (RSE) were investigated. Age- and gender-adjusted logistic regression analysis demonstrated significant association between SIS and WOT (odds ratio, 1.65; 95% confidence interval, 1.02, 2.64; P < .05), whereas there was no significant association between SIS and RPDT. Multivariable logistic regression analysis demonstrated no significant association between SIS and both WOT and RPDT, whereas there was significant association between SIS and RSE. RSE plays a key role in the development of SIS, and thoracic kyphosis might influence the development of SIS indirectly by reducing shoulder elevation induced by the restriction of the thoracic spine extension and scapular dyskinesis. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  5. Association of β-defensin copy number and psoriasis in three cohorts of European origin

    PubMed Central

    Stuart, Philip E; Hüffmeier, Ulrike; Nair, Rajan P; Palla, Raquel; Tejasvi, Trilokraj; Schalkwijk, Joost; Elder, James T; Reis, Andre; Armour, John AL

    2012-01-01

    A single previous study has demonstrated significant association of psoriasis with copy number of beta-defensin genes, using DNA from psoriasis cases and controls from Nijmegen and Erlangen. In this study we attempted to replicate that finding in larger new cohorts from Erlangen (N = 2017) and Michigan (N = 5412), using improved methods for beta-defensin copy number determination based on the paralog ratio test (PRT), and enhanced methods of analysis and association testing implemented in the CNVtools resource. We demonstrate that the association with psoriasis found in the discovery sample is maintained after applying improved typing and analysis methods (p = 5.5 × 10−4, OR = 1.25). We also find that the association is replicated in 2616 cases and 2526 controls from Michigan, although at reduced significance (p = 0.014), but not in new samples from Erlangen (1396 cases and 621 controls, p = 0.38). Meta-analysis across all cohorts suggests a nominally significant association (p = 6.6 × 10−3/2 × 10−4) with an effect size (OR = 1.081) much lower than found in the discovery study (OR = 1.32). This reduced effect size and significance on replication is consistent with a genuine but weak association. PMID:22739795

  6. Occupational asthma, eosinophil and skin prick tests and serum total IgE values of the workers in a plant manufacturing rose oil.

    PubMed

    Akkaya, A; Ornek, Z; Kaleli, S

    2004-01-01

    This study was aimed to determine the rate of occupational asthma (OA) in workers at a rose extracting plant. Specific clinical tests of 52 workers, randomly chosen from four local rose extracting plants, were statistically compared with the test results of 30 local control subjects of similar age and sex as the plant workers, but who had never worked in such a plant. There were no significant differences in pulmonary function tests (FVC, FEV1, FEV1/FVC, PEFR) between the control and test groups. Significantly higher serum total IgE values (p < 0.0001) were observed for the test subjects (239.08+/-240 IU/ml) compared to the control subjects (81.33+/-61.45 IU/ml). There were also significant differences (p < 0.0001) in the number of eosinophils between the control and test groups, with corresponding mean values of 2.28+/-2.75% and 0.73+/-1.72%, respectively. A specifically prepared skin prick test using a rose allergen (Rosa domescena) was positive for 53.84% in the test subjects whereas only 5.33% positive test results were seen in the control group. We have demonstrated the involvement of Rosa domescena pollen in occupational allergy, through IgE-mediated hypersensitivity. It was concluded that the workers of a rose oil extracting plant are more susceptible to the rose pollens.

  7. Extended Operation of Stirling Convertors in a Thermal Vacuum Environment

    NASA Technical Reports Server (NTRS)

    Oriti, Salvatore M.

    2006-01-01

    A 110 watt Stirling Radioisotope Generator (SRG110) is being developed for potential use on future NASA exploration missions. The development effort is being performed by Lockheed Martin under contract to the Department of Energy (DOE). Infinia, Corp. supplies the free-piston Stirling power convertors, and NASA Glenn Research Center (GRC) provides support to the effort in a range of technologies. This generator features higher efficiency and specific power compared to alternatives. One potential application for the generator would entail significant cruise time in the vacuum of deep space. A test has been initiated at GRC to demonstrate functionality of the Stirling convertors in a thermal vacuum environment. The test article resembles the configuration of the SRG110, however the requirement for low mass was not considered. This test demonstrates the operation of the Stirling convertors in the thermal vacuum environment, simulating deep space, over an extended period of operation. The status of the test as well as the data gathered will be presented in this paper.

  8. Design, develop and test high temperature dynamic seals for the space shuttle's aerodynamic control surfaces

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A description is given of the design, development and testing of high temperature dynamic seals for the gaps between the structure and aerodynamic control surfaces on the space shuttle. These aerodynamic seals are required to prevent high temperature airflow from damaging thermally unprotected structures and components during entry. Two seal concepts evolved a curtain seal for the spanwise elevon cove gap, and a labyrinth seal for the area above the elevon, at the gap between the end of the elevon and the fuselage. On the basis of development testing, both seal concepts were shown to be feasible for controlling internal temperatures to 350 F or less when exposed to a typical space shuttle entry environment. The curtain seal concept demonstrated excellent test results and merits strong consideration for application on the space shuttle orbiter. The labyrinth seal concept, although demonstrating significant temperature reduction characteristics, may or may not be required on the Orbiter, depending on the actual design configuration and flight environment.

  9. A Statistical Analysis of Brain Morphology Using Wild Bootstrapping

    PubMed Central

    Ibrahim, Joseph G.; Tang, Niansheng; Rowe, Daniel B.; Hao, Xuejun; Bansal, Ravi; Peterson, Bradley S.

    2008-01-01

    Methods for the analysis of brain morphology, including voxel-based morphology and surface-based morphometries, have been used to detect associations between brain structure and covariates of interest, such as diagnosis, severity of disease, age, IQ, and genotype. The statistical analysis of morphometric measures usually involves two statistical procedures: 1) invoking a statistical model at each voxel (or point) on the surface of the brain or brain subregion, followed by mapping test statistics (e.g., t test) or their associated p values at each of those voxels; 2) correction for the multiple statistical tests conducted across all voxels on the surface of the brain region under investigation. We propose the use of new statistical methods for each of these procedures. We first use a heteroscedastic linear model to test the associations between the morphological measures at each voxel on the surface of the specified subregion (e.g., cortical or subcortical surfaces) and the covariates of interest. Moreover, we develop a robust test procedure that is based on a resampling method, called wild bootstrapping. This procedure assesses the statistical significance of the associations between a measure of given brain structure and the covariates of interest. The value of this robust test procedure lies in its computationally simplicity and in its applicability to a wide range of imaging data, including data from both anatomical and functional magnetic resonance imaging (fMRI). Simulation studies demonstrate that this robust test procedure can accurately control the family-wise error rate. We demonstrate the application of this robust test procedure to the detection of statistically significant differences in the morphology of the hippocampus over time across gender groups in a large sample of healthy subjects. PMID:17649909

  10. Using 3D computer simulations to enhance ophthalmic training.

    PubMed

    Glittenberg, C; Binder, S

    2006-01-01

    To develop more effective methods of demonstrating and teaching complex topics in ophthalmology with the use of computer aided three-dimensional (3D) animation and interactive multimedia technologies. We created 3D animations and interactive computer programmes demonstrating the neuroophthalmological nature of the oculomotor system, including the anatomy, physiology and pathophysiology of the extra-ocular eye muscles and the oculomotor cranial nerves, as well as pupillary symptoms of neurological diseases. At the University of Vienna we compared their teaching effectiveness to conventional teaching methods in a comparative study involving 100 medical students, a multiple choice exam and a survey. The comparative study showed that our students achieved significantly better test results (80%) than the control group (63%) (diff. = 17 +/- 5%, p = 0.004). The survey showed a positive reaction to the software and a strong preference to have more subjects and techniques demonstrated in this fashion. Three-dimensional computer animation technology can significantly increase the quality and efficiency of the education and demonstration of complex topics in ophthalmology.

  11. Diesel Fueled SOFC for Class 7/Class 8 On-Highway Truck Auxiliary Power

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vesely, Charles John-Paul; Fuchs, Benjamin S.; Booten, Chuck W.

    2010-03-31

    The following report documents the progress of the Cummins Power Generation (CPG) Diesel Fueled SOFC for Class 7/Class 8 On-Highway Truck Auxiliary Power (SOFC APU) development and final testing under the U.S. Department of Energy (DOE) Energy Efficiency and Renewable Energy (EERE) contract DE-FC36-04GO14318. This report overviews and summarizes CPG and partner development leading to successful demonstration of the SOFC APU objectives and significant progress towards SOFC commercialization. Significant SOFC APU Milestones: Demonstrated: Operation meeting SOFC APU requirements on commercial Ultra Low Sulfur Diesel (ULSD) fuel. SOFC systems operating on dry CPOX reformate. Successful start-up and shut-down of SOFC APUmore » system without inert gas purge. Developed: Low cost balance of plant concepts and compatible systems designs. Identified low cost, high volume components for balance of plant systems. Demonstrated efficient SOFC output power conditioning. Demonstrated SOFC control strategies and tuning methods.« less

  12. Bacopa monnieri: An evaluation of antihyperglycemic and antinociceptive potential of methanolic extract of whole plants.

    PubMed

    Taznin, Inin; Mukti, Mohsina; Rahmatullah, Mohammed

    2015-11-01

    Antihyperglycemic and antinociceptive activity studies were carried out with methanolic extract of whole plants of Bacopa monnieri, respectively, through oral glucose tolerance test and gastric pain model induced by acetic acid in Swiss albino mice. In OGTT (oral glucose tolerance tests) conducted with glucose-challenged mice, the extract, administered at four doses of 50, 100, 200 and 400mg per kg body weight, dose-dependently and significantly inhibited the increase in serum glucose concentrations, respectively, by 33.3, 34.2, 42.1 and 44.2%. A standard antihyperglycemic drug, glibenclamide, when administered at a dose of 10mg per kg body weight, inhibited increase in serum glucose concentration by 50.7%. From the results, it can be concluded that the methanolic extract of the plant possess significant antihyperglycemic potential. In antinociceptive activity tests, administration of the extract at the aforementioned four doses also significantly and dose-dependently reduced the number of acetic acid-induced gastric constrictions in mice. The percent inhibitions in gastric constrictions were, respectively, 43.4, 46.6, 50.0, and 53.4 at the above four doses. A reference antinociceptive drug, aspirin, when administered at a dose of 200 mg per kg body weight, reduced the number of gastric constrictions by 40.0%. Thus the extract at even the lowest dose of 50 mg, demonstrated antinociceptive activity better than that of aspirin, and which activity was much more than aspirin at the other three higher doses tested. The results demonstrate that the plant can be an excellent candidate for further studies towards isolation of antihyperglycemic and pain-killing compounds.

  13. Separator for lithium-sulfur battery based on polymer blend membrane

    NASA Astrophysics Data System (ADS)

    Freitag, Anne; Stamm, Manfred; Ionov, Leonid

    2017-09-01

    In this work we report a novel way of reducing the polysulfide shuttle in lithium-sulfur batteries by a new separator material. Polyvinylsulfate potassium salt (PVSK) as polymeric additive is introduced into a polyvinylidene fluoride-hexafluoropropylene (PVdF-HFP) matrix membrane to improve the battery performance. PVSK is expected to lower the polysulfide mobility due to interaction with the sulfonic group. PVdF-HFP/PVSK blend membranes are prepared and an UV/Vis polysulfide diffusion test clearly demonstrates the positive effect of PVSK. Electrochemical testing reveals a significant improvement of cycling stability up to more than 200 cycles. In addition, the effect of separator porosity to the polysulfide shuttle is investigated with PVdF-HFP membranes of different porosity. A simple polysulfide diffusion test and potentiostatic charge/discharge cycling clearly demonstrate that low separator porosity is favorable in a lithium-sulfur cell.

  14. The unicellular fungal tool RhoTox for risk assessments in groundwater systems.

    PubMed

    Lategan, Maria Josie; Klare, William; Kidd, Sarah; Hose, Grant C; Nevalainen, Helena

    2016-10-01

    The recent inclusion of yeasts in environmental monitoring recognizes their ecological significance and sensitivity to toxicants. Here we present a robust and simple two-step toxicity assay and demonstrate the sensitivity of an ubiquitous groundwater yeast, Rhodotorula minuta, to a range of metals and metalloids. The test species was sensitive to copper with a 24h EC50 of 35µg Cu/L, followed in order of decreasing sensitivity by zinc, chromium (VI) and arsenic (EC50 4.40mg As (III)/L). The strain demonstrated an unexpected tolerance to chromium (VI), having an EC50 value (3.45mg Cr (VI)/L) similar to that of arsenic. The inclusion of a unicellular, microbial test-species into the suite of existing multicellular test species for toxicity evaluation is a key step towards strengthening the assessment of risk for groundwater ecosystems. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Performance and Life Tests of a Regenerative Blower for EVA Suit Ventilation

    NASA Technical Reports Server (NTRS)

    Izenson, Michael G.; Chen, Weibo; McCormick, John; Paul, Heather L.; Jennings, Mallory A.

    2012-01-01

    Ventilation fans for future space suits must meet demanding performance specifications, satisfy stringent safety requirements for operation in an oxygen atmosphere, and be able to increase output to operate in buddy mode. A regenerative blower is an attractive choice due to its ability to meet these requirements at low operating speed. This paper describes progress in the development and testing of a regenerative blower designed to meet requirements for ventilation subsystems in future space suits. The blower includes a custom-designed motor that has significantly improved its efficiency. We have measured the blower s head/flow performance and power consumption under conditions that simulate both the normal and buddy mode operating points. We have operated the blower for TBD hours and demonstrated safe operation in an oxygen test loop at prototypical pressures. We also demonstrated operation with simulated lunar dust.

  16. CERTS Microgrid Laboratory Test Bed - PIER Final Project Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eto, Joseph H.; Eto, Joseph H.; Lasseter, Robert

    2008-07-25

    The objective of the CERTS Microgrid Laboratory Test Bed project was to enhance the ease of integrating small energy sources into a microgrid. The project accomplished this objective by developing and demonstrating three advanced techniques, collectively referred to as the CERTS Microgrid concept, that significantly reduce the level of custom field engineering needed to operate microgrids consisting of small generating sources. The techniques comprising the CERTS Microgrid concept are: 1) a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation; 2) an approach to electrical protection within the microgrid that does not depend on highmore » fault currents; and 3) a method for microgrid control that achieves voltage and frequency stability under islanded conditions without requiring high-speed communications. The techniques were demonstrated at a full-scale test bed built near Columbus, Ohio and operated by American Electric Power. The testing fully confirmed earlier research that had been conducted initially through analytical simulations, then through laboratory emulations, and finally through factory acceptance testing of individual microgrid components. The islanding and resychronization method met all Institute of Electrical and Electronics Engineers 1547 and power quality requirements. The electrical protections system was able to distinguish between normal and faulted operation. The controls were found to be robust and under all conditions, including difficult motor starts. The results from these test are expected to lead to additional testing of enhancements to the basic techniques at the test bed to improve the business case for microgrid technologies, as well to field demonstrations involving microgrids that involve one or mroe of the CERTS Microgrid concepts.« less

  17. Parachute Testing for the NASA X-38 Crew Return Vehicle

    NASA Technical Reports Server (NTRS)

    Stein, Jenny M.

    2005-01-01

    NASA's X-38 program was an in-house technology demonstration program to develop a Crew Return Vehicle (CRV) for the International Space Station capable of returning seven crewmembers to Earth when the Space Shuttle was not present at the station. The program, managed out of NASA's Johnson Space Center, was started in 1995 and was cancelled in 2003. Eight flights with a prototype atmospheric vehicle were successfully flown at Edwards Air Force Base, demonstrating the feasibility of a parachute landing system for spacecraft. The intensive testing conducted by the program included testing of large ram-air parafoils. The flight test techniques, instrumentation, and simulation models developed during the parachute test program culminated in the successful demonstration of a guided parafoil system to land a 25,000 Ib spacecraft. The test program utilized parafoils of sizes ranging from 750 to 7500 p. The guidance, navigation, and control system (GN&C) consisted of winches, laser or radar altimeter, global positioning system (GPS), magnetic compass, barometric altimeter, flight computer, and modems for uplink commands and downlink data. The winches were used to steer the parafoil and to perform the dynamic flare maneuver for a soft landing. The laser or radar altimeter was used to initiate the flare. In the event of a GPS failure, the software navigated by dead reckoning using the compass and barometric altimeter data. The GN&C test beds included platforms dropped from cargo aircraft, atmospheric vehicles released from a 8-52, and a Buckeye powered parachute. This paper will describe the test program and significant results.

  18. Level of visual acuity necessary to avoid false-positives on the HRR and Ishihara color vision tests.

    PubMed

    Ng, Jason S; Shih, Brian

    2017-05-11

    Minimizing false-positives (FPs) when evaluating color vision is important in eye care. Identification of plate 1 (demonstration plate) is often considered a way to avoid FPs. However, few studies have quantified the minimum level of visual acuity (VA) that would minimize FPs for the Ishihara and HRR color tests. Threshold levels of optical defocus were obtained from 25 color normal subjects. Blur levels were obtained for Ishihara (38 plate) plates 1, 10, and 15 and 4th edition HRR plates 1, 7, 10, and 20 using the method of limits. Corresponding VAs were measured through these blur levels at 40 centimeters after adjusting for the dioptric distance difference. Analysis of variance testing was used to analyze the data. Mean optical defocus values in diopters (mean ± SD) for HRR plates 1, 7, 10, and 20 were 6.23 ± 1.61, 1.23 ± 1.16, 2.41 ± 1.31, and 7.96 ± 2.03, respectively, and for Ishihara plates 1, 10, and 15 were 5.70 ± 1.52, 3.68 ± 1.71, and 4.62 ± 1.56, respectively. There was a significant difference between the screening and demonstration plates for both tests (p<0.001). Based on the plate in each test that was found to be the least tolerant to blur, the average minimum VAs needed to identify the screening plates were approximately 20/180 for the Ishihara test and 20/50 for the HRR test. Identifying the demonstration plate in the Ishihara and HRR tests does not ensure FPs will be avoided.

  19. Robotic Lunar Lander Development Status

    NASA Technical Reports Server (NTRS)

    Ballard, Benjamin; Cohen, Barbara A.; McGee, Timothy; Reed, Cheryl

    2012-01-01

    NASA Marshall Space Flight Center and John Hopkins University Applied Physics Laboratory have developed several mission concepts to place scientific and exploration payloads ranging from 10 kg to more than 200 kg on the surface of the moon. The mission concepts all use a small versatile lander that is capable of precision landing. The results to date of the lunar lander development risk reduction activities including high pressure propulsion system testing, structure and mechanism development and testing, and long cycle time battery testing will be addressed. The most visible elements of the risk reduction program are two fully autonomous lander flight test vehicles. The first utilized a high pressure cold gas system (Cold Gas Test Article) with limited flight durations while the subsequent test vehicle, known as the Warm Gas Test Article, utilizes hydrogen peroxide propellant resulting in significantly longer flight times and the ability to more fully exercise flight sensors and algorithms. The development of the Warm Gas Test Article is a system demonstration and was designed with similarity to an actual lunar lander including energy absorbing landing legs, pulsing thrusters, and flight-like software implementation. A set of outdoor flight tests to demonstrate the initial objectives of the WGTA program was completed in Nov. 2011, and will be discussed.

  20. NASA's Robotic Lunar Lander Development Program

    NASA Technical Reports Server (NTRS)

    Ballard, Benjamin W.; Reed, Cheryl L. B.; Artis, David; Cole, Tim; Eng, Doug S.; Kubota, Sanae; Lafferty, Paul; McGee, Timothy; Morese, Brian J.; Chavers, Gregory; hide

    2012-01-01

    NASA Marshall Space Flight Center and the Johns Hopkins University Applied Physics Laboratory have developed several mission concepts to place scientific and exploration payloads ranging from 10 kg to more than 200 kg on the surface of the moon. The mission concepts all use a small versatile lander that is capable of precision landing. The results to date of the lunar lander development risk reduction activities including high pressure propulsion system testing, structure and mechanism development and testing, and long cycle time battery testing will be addressed. The most visible elements of the risk reduction program are two fully autonomous lander flight test vehicles. The first utilized a high pressure cold gas system (Cold Gas Test Article) with limited flight durations while the subsequent test vehicle, known as the Warm Gas Test Article, utilizes hydrogen peroxide propellant resulting in significantly longer flight times and the ability to more fully exercise flight sensors and algorithms. The development of the Warm Gas Test Article is a system demonstration and was designed with similarity to an actual lunar lander including energy absorbing landing legs, pulsing thrusters, and flight-like software implementation. A set of outdoor flight tests to demonstrate the initial objectives of the WGTA program was completed in Nov. 2011, and will be discussed.

  1. Overcoming the effects of false positives and threshold bias in graph theoretical analyses of neuroimaging data.

    PubMed

    Drakesmith, M; Caeyenberghs, K; Dutt, A; Lewis, G; David, A S; Jones, D K

    2015-09-01

    Graph theory (GT) is a powerful framework for quantifying topological features of neuroimaging-derived functional and structural networks. However, false positive (FP) connections arise frequently and influence the inferred topology of networks. Thresholding is often used to overcome this problem, but an appropriate threshold often relies on a priori assumptions, which will alter inferred network topologies. Four common network metrics (global efficiency, mean clustering coefficient, mean betweenness and smallworldness) were tested using a model tractography dataset. It was found that all four network metrics were significantly affected even by just one FP. Results also show that thresholding effectively dampens the impact of FPs, but at the expense of adding significant bias to network metrics. In a larger number (n=248) of tractography datasets, statistics were computed across random group permutations for a range of thresholds, revealing that statistics for network metrics varied significantly more than for non-network metrics (i.e., number of streamlines and number of edges). Varying degrees of network atrophy were introduced artificially to half the datasets, to test sensitivity to genuine group differences. For some network metrics, this atrophy was detected as significant (p<0.05, determined using permutation testing) only across a limited range of thresholds. We propose a multi-threshold permutation correction (MTPC) method, based on the cluster-enhanced permutation correction approach, to identify sustained significant effects across clusters of thresholds. This approach minimises requirements to determine a single threshold a priori. We demonstrate improved sensitivity of MTPC-corrected metrics to genuine group effects compared to an existing approach and demonstrate the use of MTPC on a previously published network analysis of tractography data derived from a clinical population. In conclusion, we show that there are large biases and instability induced by thresholding, making statistical comparisons of network metrics difficult. However, by testing for effects across multiple thresholds using MTPC, true group differences can be robustly identified. Copyright © 2015. Published by Elsevier Inc.

  2. Historical Contributions to Vertical Flight at the NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Hodges, William T.; Gorton, Susan A.; Jackson, Karen E.

    2016-01-01

    The NASA Langley Research Center has had a long and distinguished history in powered lift technology development. This research has formed the foundation of knowledge for the powered lift community worldwide. From aerodynamics to structures, aeromechanics, powered lift, acoustics, materials, stability & control, structural dynamics and human factors, Langley has made significant contributions to the advancement of vertical lift technologies. This research has encompassed basic phenomenological studies through subscale laboratory testing, analytical tool development, applied demonstrations and full scale flight-testing. Since the dedication of Langley in 1920, it has contributed to the understanding, design, analysis, and flight test development of experimental and production V/STOL configurations. This paper will chronicle significant areas of research through the decades from 1920 to 2015 with historical photographs and references.

  3. Early Intervention and Its Effects on Maternal and Child Development.

    ERIC Educational Resources Information Center

    Slaughter, Diana T.

    1983-01-01

    The longitudinal study reported used an intervention strategy to test the thesis that sociocultural background, mediated by maternal attitudes and behaviors, influences Black children's early development in educationally significant ways. Two models of parent education were contrasted: the Levenstein toy demonstration program and the…

  4. Sleeve expansion of bolt holes in railroad rail. volume III - field experiment results

    DOT National Transportation Integrated Search

    1998-02-01

    The bolt-hole cold-expansion process has been demonstrated by laboratory tests to significantly affect the initiation and propagation of fatigue cracks from rail bolt holes such that a reduction of the incidence of rail-bolt-holde failure in cold-exp...

  5. Wind tunnel and field evaluation of drift from aerial spray applications with multiple spray formulations

    USDA-ARS?s Scientific Manuscript database

    The impact of different spray tank modifiers into an active ingredient spray mixture on spray atomization and in-field behavior under aerial application conditions were examined. Wind tunnel tests demonstrated that active ingredient solutions potentially results in significantly different atomizati...

  6. Aconitine "challenge" test reveals a single whole-body exposure to diesel exhaust increases cardiac arrhythmia risk in hypertensive rats

    EPA Science Inventory

    Epidemiological studies demonstrate a significant association between cardiac electrical dysfunction, arrhythmias and air pollution exposure. Sensitivity to aconitine-induced arrhythmia has been used repeatedly to examine the factors that increase the risk of such cardiac electri...

  7. Characteristics of High-Quality Teachers

    ERIC Educational Resources Information Center

    Jones, Jason E.; Gulek, James C.

    2010-01-01

    The purpose of this study was to examine the characteristics of high-quality teachers who used a structured mathematics program for teaching, namely the Math Achievement Program (MAP[superscript 2]D), which demonstrated significant gains on student achievement as measured by California's Standards Test (CST) in mathematics. Specifically, the…

  8. Regression of Moral Reasoning during Medical Education: Combined Design Study to Evaluate the Effect of Clinical Study Years

    PubMed Central

    Hren, Darko; Marušić, Matko; Marušić, Ana

    2011-01-01

    Background Moral reasoning is important for developing medical professionalism but current evidence for the relationship between education and moral reasoning does not clearly apply to medical students. We used a combined study design to test the effect of clinical teaching on moral reasoning. Methods We used the Defining Issues Test-2 as a measure of moral judgment, with 3 general moral schemas: Personal Interest, Maintaining Norms, and Postconventional Schema. The test was applied to 3 consecutive cohorts of second year students in 2002 (n = 207), 2003 (n = 192), and 2004 (n = 139), and to 707 students of all 6 study years in 2004 cross-sectional study. We also tested 298 age-matched controls without university education. Results In the cross-sectional study, there was significant main effect of the study year for Postconventional (F(5,679) = 3.67, P = 0.003) and Personal Interest scores (F(5,679) = 3.38, P = 0.005). There was no effect of the study year for Maintaining Norms scores. 3rd year medical students scored higher on Postconventional schema score than all other study years (p<0.001). There were no statistically significant differences among 3 cohorts of 2nd year medical students, demonstrating the absence of cohort or point-of-measurement effects. Longitudinal study of 3 cohorts demonstrated that students regressed from Postconventional to Maintaining Norms schema-based reasoning after entering the clinical part of the curriculum. Interpretation Our study demonstrated direct causative relationship between the regression in moral reasoning development and clinical teaching during medical curriculum. The reasons may include hierarchical organization of clinical practice, specific nature of moral dilemmas faced by medical students, and hidden medical curriculum. PMID:21479204

  9. Impact of a surgical site infection reduction strategy after colorectal resection.

    PubMed

    Connolly, T M; Foppa, C; Kazi, E; Denoya, P I; Bergamaschi, R

    2016-09-01

    This study was performed to determine the impact of a surgical site infection (SSI) reduction strategy on SSI rates following colorectal resection. American College of Surgeons National Surgical Quality Improvement Program (NSQIP) data from 2006-14 were utilized and supplemented by institutional review board-approved chart review. The primary end-point was superficial and deep incisional SSI. The inclusion criterion was colorectal resection. The SSI reduction strategy consisted of preoperative (blood glucose, bowel preparation, shower, hair removal), intra-operative (prophylactic antibiotics, antimicrobial incisional drape, wound protector, wound closure technique) and postoperative (wound dressing technique) components. The SSI reduction strategy was prospectively implemented and compared with historical controls (pre-SSI strategy arm). Statistical analysis included Pearson's chi-square test, and Student's t-test performed with spss software. Of 1018 patients, 379 were in the pre-SSI strategy arm, 311 in the SSI strategy arm and 328 were included to test durability. The study arms were comparable for all measured parameters. Preoperative wound class, operation time, resection type and stoma creation did not differ significantly. The SSI strategy arm demonstrated a significant decrease in overall SSI rates (32.19% vs 18.97%) and superficial SSI rates (23.48% vs 8.04%). Deep SSI and organ space rates did not differ. A review of patients testing durability demonstrated continued improvement in overall SSI rates (8.23%). The implementation of an SSI reduction strategy resulted in a 41% decrease in SSI rates following colorectal resection over its initial 3 years, and its durability as demonstrated by continuing improvement was seen over an additional 2 years. Colorectal Disease © 2015 The Association of Coloproctology of Great Britain and Ireland.

  10. A 6-year-old girl with restricted upward gaze of her right eye.

    PubMed

    Tuli, Sanjeev; Tuli, Sonal

    2012-08-01

    Brown syndrome is an incomitant strabismus syndrome characterized by inability of the eye to elevate during adduction. • Primary Brown syndrome is thought to occur due to the inability of the superior oblique tendon to stretch.However, there are many secondary causes of this condition that must be ruled out. • Despite significant misalignment of the eyes during upgaze, patients with Brown syndrome usually do not have decreased vision or diplopia with primary gaze. • Unlike paralytic strabismus, forced duction tests demonstrate restriction and a Parks’ three-step test does not demonstrate a paralytic muscle. Spontaneous resolution is frequent, and surgical management typically is not indicated because of the high incidence of postoperative symptomatic superior oblique palsy.

  11. Seizure entrainment with polarizing low-frequency electric fields in a chronic animal epilepsy model

    NASA Astrophysics Data System (ADS)

    Sunderam, Sridhar; Chernyy, Nick; Peixoto, Nathalia; Mason, Jonathan P.; Weinstein, Steven L.; Schiff, Steven J.; Gluckman, Bruce J.

    2009-08-01

    Neural activity can be modulated by applying a polarizing low-frequency (Lt100 Hz) electric field (PLEF). Unlike conventional pulsed stimulation, PLEF stimulation has a graded, modulatory effect on neuronal excitability, and permits the simultaneous recording of neuronal activity during stimulation suitable for continuous feedback control. We tested a prototype system that allows for simultaneous PLEF stimulation with minimal recording artifact in a chronic tetanus toxin animal model (rat) of hippocampal epilepsy with spontaneous seizures. Depth electrode local field potentials recorded during seizures revealed a characteristic pattern of field postsynaptic potentials (fPSPs). Sinusoidal voltage-controlled PLEF stimulation (0.5-25 Hz) was applied in open-loop cycles radially across the CA3 of ventral hippocampus. For stimulated seizures, fPSPs were transiently entrained with the PLEF waveform. Statistical significance of entrainment was assessed with Thomson's harmonic F-test, with 45/132 stimulated seizures in four animals individually demonstrating significant entrainment (p < 0.04). Significant entrainment for multiple presentations at the same frequency (p < 0.01) was observed in three of four animals in 42/64 stimulated seizures. This is the first demonstration in chronically implanted freely behaving animals of PLEF modulation of neural activity with simultaneous recording.

  12. Comparative effect of a new mouthrinse containing chlorhexidine, triclosan and zinc on volatile sulphur compounds: a randomized, crossover, double-blind study.

    PubMed

    Mendes, L; Coimbra, J; Pereira, A L; Resende, M; Pinto, M G

    2016-08-01

    The aims of this study were to compare the volatile sulphur compounds (VSC)-reducing effect of two commercial mouthrinses using a morning bad breath model and to assess the role of mechanical plaque control (MPC) when performed previously to mouthrinse use. Eleven volunteers with good oral health were enrolled in a double-blind, randomized, six-step crossover design study with a 7-day washout period. Two commercial mouthrinses were tested using a saline solution (NaCl 0.9%) as a negative control: one mouthrinse contained 0.05% chlorhexidine, 0.05% cetylpyridinium chloride and 0.14% zinc lactate (CHX-CPC-Zn), while the other contained 0.05% chlorhexidine, 0.15% triclosan and 0.18% zinc pidolate (CHX-triclosan-Zn). A portable sulphide monitor (Halimeter(®) ) was used for VSC quantification. Measurements were made at baseline, and 1, 3 and 5 h after rinsing. Significant differences were detected by analysis of variance. No significant differences between groups were detected at baseline. We were unable to demonstrate a significant influence of mechanical plaque control on the reduction of VSC levels when performed before mouthrinse use (P = 0.631). Both mouthrinses effectively lowered VSC levels in all test intervals (P < 0.05). No statistically significant differences were found between mouthrinses in any of the test intervals (P = 0.629, 0.069 and 0.598 at 1, 3 and 5 h). This study demonstrated that CHX-CPC-Zn and CHX-triclosan-Zn have significant and similar effects in reducing VSC levels, which persist for at least 5 h. Such effects were independent of previous MPC, which failed to improve on the results of mouthrinse use alone. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Intrabolus pressure on high-resolution manometry distinguishes fibrostenotic and inflammatory phenotypes of eosinophilic esophagitis.

    PubMed

    Colizzo, J M; Clayton, S B; Richter, J E

    2016-08-01

    The aim of this investigation was to determine the motility patterns of inflammatory and fibrostenotic phenotypes of eosinophilic esophagitis (EoE) utilizing high-resolution manometry (HRM). Twenty-nine patients with a confirmed diagnosis of EoE according to clinicopathological criteria currently being managed at the Joy McCann Culverhouse Swallowing Center at the University of South Florida were included in the retrospective analysis. Only patients who completed HRM studies were included in the analysis. Patients were classified into inflammatory or fibrostenotic subtypes based on baseline endoscopic evidence. Their baseline HRM studies prior to therapy were analyzed. Manometric data including distal contractile integral, integrated relaxation pressure, and intrabolus pressure (IBP) values were recorded. HRM results were interpreted according to the Chicago Classification system. Statistical analysis was performed with SPSS software (Version 22, IBM Co., Armonk, NY, USA). Data were compared utilizing Student's t-test, χ(2) test, Pearson correlation, and Spearman correlation tests. Statistical significance was set at P < 0.05. A total of 29 patients with EoE were included into the retrospective analysis. The overall average age among patients was 40 years. Male patients comprised 62% of the overall population. Both groups were similar in age, gender, and overall clinical presentation. Seventeen patients (58%) had fibrostenotic disease, and 12 (42%) displayed inflammatory disease. The average IBP for the fibrostenotic and inflammatory groups were 18.6 ± 6.0 mmHg and 12.6 ± 3.5 mmHg, respectively (P < 0.05). Strictures were only seen in the fibrostenotic group. Of the fibrostenotic group, 6 (35%) demonstrated proximal esophageal strictures, 7 (41%) had distal strictures, 3 (18%) had mid-esophageal strictures, and 1 (6%) patient had pan-esophageal strictures. There was no statistically significant correlation between the level of esophageal stricture and degree of IBP. Integrated relaxation pressure, distal contractile integral, and other HRM metrics did not demonstrate statistical significance between the two subtypes. There also appeared no statistically significant correlation between patient demographics and esophageal metrics. Patients with the fibrostenotic phenotype of EoE demonstrated an IBP that was significantly higher than that of the inflammatory group. © 2015 International Society for Diseases of the Esophagus.

  14. Aiming for excellence - A simulation-based study on adapting and testing an instrument for developing non-technical skills in Norwegian student nurse anaesthetists.

    PubMed

    Flynn, Fiona M; Sandaker, Kjersti; Ballangrud, Randi

    2017-01-01

    There is increasing focus on building safety into anaesthesia practice, with excellence in anaesthesia as an aspirational goal. Non-technical skills are an important factor in excellence and improved patient safety, though there have been few systematic attempts at integrating them into anaesthesia nursing education. This study aimed to test the reliability of NANTS-no, a specially adapted behavioural marker system for nurse anaesthetists in Norway, and explore the development of non-technical skills in student nurse anaesthetists. The pre-test post-test design incorporated a 10-week simulation-based programme, where non-technical skills in 14 student nurse anaesthetists were rated on three different occasions during high-fidelity simulation, before and after taking part in a training course. NANTS-no demonstrated high overall inter-rater reliability (ICC = 0.91), high test-retest reliability (ICC = 0.94) and good internal consistency (Cronbach's α of 0.85-0.92). A significant improvement was demonstrated across all categories of non-technical skills, with greatest improvements between the first and third and second and third sessions. There was also a significant improvement in two categories between the first and second sessions. NANTS-no is therefore suitable for assessing non-technical skills during simulation training in anaesthesia nursing education. More research is needed to validate its use in clinical practice. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Suitport Feasibility: Development and Test of a Suitport and Space Suit for Human Pressurized Space Suit Donning Tests

    NASA Technical Reports Server (NTRS)

    Boyle, Robert M.; Mitchell, Kathryn; Allton, Charles; Ju, Hsing

    2012-01-01

    The suitport concept has been recently implemented as part of the small pressurized lunar rover (Currently the Space Exploration vehicle, or SEV) and the Multi-Mission Space Exploration Vehicle (MMSEV) concept demonstrator vehicle. Suitport replaces or augments the traditional airlock function of a spacecraft by providing a bulkhead opening, capture mechanism, and sealing system to allow ingress and egress of a space suit while the space suit remains outside of the pressurized volume of the spacecraft. This presents significant new opportunities to EVA exploration in both microgravity and surface environments. The suitport concept will enable three main improvements in EVA by providing reductions in: pre-EVA time from hours to less than thirty minutes; airlock consumables; contamination returned to the cabin with the EVA crewmember. To date, the first generation suitport has been tested with mockup suits on the rover cabins and pressurized on a bench top engineering unit. The work on the rover cabin has helped define the operational concepts and timelines, and has demonstrated the potential of suitport to save significant amounts of crew time before and after EVAs. The work with the engineering unit has successfully demonstrated the pressurizable seal concept including the ability to seal after the introduction and removal of contamination to the sealing surfaces. Using this experience, a second generation suitport was designed. This second generation suitport has been tested with a space suit prototype on the second generation MMSEV cabin, and testing is planned using the pressure differentials of the spacecraft. Pressurized testing will be performed using the JSC B32 Chamber B, a human rated vacuum chamber. This test will include human rated suitports, a suitport compatible prototype suit, and chamber modifications. This test will bring these three elements together in the first ever pressurized donning of a rear entry suit through a suitport. This paper presents the design of a human rated second generation suitport, the design of a suit capable of supporting pressurized human donning through a suitport, ambient pressure testing of the suit with the suitport, and modifications to the JSC human rated chamber B to accept a suitport. Design challenges and solutions, as well as compromises required to develop the system, are presented. Initial human testing results are presented.

  16. Further validation and definition of the psychometric properties of the Asthma Impact Survey.

    PubMed

    Schatz, Michael; Zeiger, Robert S; Yang, Su-Jau; Chen, Wansu; Kosinski, Mark

    2011-07-01

    The Asthma Impact Survey (AIS-6) is a brief disease-specific quality-of-life instrument with limited published validation data. To obtain additional validation data and psychometric properties of the AIS-6. In November, 2007, patients with persistent asthma were mailed a survey that included the AIS-6, the mini-Asthma Quality of Life Questionnaire (mAQLQ), and the Asthma Control Test (ACT). Follow-up surveys were sent in April, July, and October 2008. Year 2008 exacerbations and short-acting β-agonist (SABA) dispensings were captured from administrative data. A total of 2680 patients had complete baseline survey data. Criterion validity was demonstrated by the strong correlations of the AIS-6 with the mAQLQ (r = -0.84 to -0.86); construct validity by significant relationships (P < .0001) of the AIS-6 with mAQLQ domain scores, ACT score, and history of exacerbations; and predictive validity by significant relationships (P < .0001) between AIS-6 scores at the end of 2007 and year 2008 exacerbations and high SABA dispensings. Responsiveness was demonstrated by significant (P < .0001) correlations (r = -0.39 to -0.58) between changes in AIS-6 scores and changes in mAQLQ and ACT scores over time. A preliminary minimally important difference (MID) in AIS-6 was estimated to be 4 by using the mAQLQ MID as an anchor. Excellent internal consistency (α = 0.94) and test-retest reliability (intraclass correlation coefficient = 0.86-0.91) were also demonstrated. The AIS-6 demonstrated good psychometric properties in a large independent sample and could be used to assess asthma-specific quality of life in clinical practice and clinical research. Copyright © 2011 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  17. Engineering development program of a closed aluminum-oxygen semi-cell system for an unmanned underwater vehicle: An update

    NASA Astrophysics Data System (ADS)

    Gregg, Dane W.; Hall, Susan E.

    1995-04-01

    Most emerging unmanned undersea vehicle (UUV) missions require significantly longer range and endurance than is achievable with existing battery technology. The Aluminum-Oxygen (Al-O2) semi-cell is a candidate technology capable of providing a significant improvement in endurance compared to the silver-zinc battery technology currently used in UUVs and compares favorably to other proposed UUV power systems not only in performance, but also in safety and logistics. An Al-O2 semi-cell system is under development by Loral Defense Systems-Akron (Loral) for the ARPA/Navy 44 in. diameter UUV test vehicle. The power plant consists of a cell stack, gas management, oxygen storage, electrolyte management, coolant and controller subsystems, designed to replace the existing silver-zinc battery and meet existing weight, volume, electrical and thermal requirements, therefore minimizing modifications to the UUV. A detailed system design is complete. A component and material endurance test to evaluate compatibility and reliability of various material arid components is complete. Sub scale (Short stack) system testing is completed. A full-scale demonstration unit is now under construction in the second half of 1995. The full scale demonstration test will simulate environmental conditions of the operational system. This paper summarizes the results of the extensive short stack and endurance test programs, describes the plan for full-scale testing, and concludes with a brief discussions of future directions for this technology. This program is sponsored by ARPA Maritime Systems Technology Office under NASA contract NAS3-26715.

  18. Quantification of pronator quadratus contribution to isometric pronation torque of the forearm.

    PubMed

    McConkey, Mark O; Schwab, Timothy D; Travlos, Andrew; Oxland, Thomas R; Goetz, Thomas

    2009-11-01

    The contribution of the pronator quadratus (PQ) muscle in generation of pronation torque has not been determined. The purpose of this study was to investigate pronation torque in healthy volunteers before and after temporary paralysis of the PQ with lidocaine, under electromyographic guidance. A custom apparatus was designed to allow isometric testing of pronation torque at 5 positions of rotation: 90 degrees of supination, 45 degrees of supination, neutral, 45 degrees of pronation, and 80 degrees of pronation. After validation of the apparatus, 17 (9 male, 8 female) right-hand-dominant volunteers were recruited. They were tested at all 5 positions in random order and then had their PQ muscles paralyzed with lidocaine. Repeat testing was performed in the same random order 30 minutes after injection. Three unblinded subjects underwent testing after injection of saline instead of lidocaine to determine effect of fluid volume alone on PQ function. The validation trial demonstrated reproducibility of the testing apparatus. After paralysis of PQ with lidocaine, pronation torque decreased by an average 21% (range, 16.7% to 23.2%) at all positions compared with preinjection testing. All were statistically significant except at 80 degrees of pronation. The subjects who underwent injection of saline showed no evidence of decrease in pronation torque. This study demonstrated a significant decrease in pronation torque with controlled elimination of PQ function. Open reduction and internal fixation of distal radius fractures damages the PQ and may result in a pronation torque deficit. Pronation torque measurement may help in postoperative outcome analysis of surgical procedures using the volar approach to the distal radius.

  19. Short Duration Base Heating Test Improvements

    NASA Technical Reports Server (NTRS)

    Bender, Robert L.; Dagostino, Mark G.; Engel, Bradley A.; Engel, Carl D.

    1999-01-01

    Significant improvements have been made to a short duration space launch vehicle base heating test technique. This technique was first developed during the 1960's to investigate launch vehicle plume induced convective environments. Recent improvements include the use of coiled nitrogen buffer gas lines upstream of the hydrogen / oxygen propellant charge tubes, fast acting solenoid valves, stand alone gas delivery and data acquisition systems, and an integrated model design code. Technique improvements were successfully demonstrated during a 2.25% scale X-33 base heating test conducted in the NASA/MSFC Nozzle Test Facility in early 1999. Cost savings of approximately an order of magnitude over previous tests were realized due in large part to these improvements.

  20. The effects of acute hypoglycaemia on memory acquisition and recall and prospective memory in type 1 diabetes.

    PubMed

    Warren, R E; Zammitt, N N; Deary, I J; Frier, B M

    2007-01-01

    Global memory performance is impaired during acute hypoglycaemia. This study assessed whether moderate hypoglycaemia disrupts learning and recall in isolation, and utilised a novel test of prospective memory which may better reflect the role of memory in daily life than conventional tests. Thirty-six subjects with type 1 diabetes participated, 20 with normal hypoglycaemia awareness (NHA) and 16 with impaired hypoglycaemia awareness (IHA). Each underwent a hypoglycaemic clamp with target blood glucose 2.5 mmol/l. Prior to hypoglycaemia, subjects attempted to memorise instructions for a prospective memory task, and recall was assessed during hypoglycaemia. Subjects then completed the learning and immediate recall stages of three conventional memory tasks (word recall, story recall, visual recall) during hypoglycaemia. Euglycaemia was restored and delayed memory for the conventional tasks was tested. The same procedures were completed in euglycaemic control studies (blood glucose 4.5 mmol/l). Hypoglycaemia impaired performance significantly on the prospective memory task (p = 0.004). Hypoglycaemia also significantly impaired both immediate and delayed recall for the word and story recall tasks (p < 0.01 in each case). There was no significant deterioration of performance on the visual memory task. The effect of hypoglycaemia did not differ significantly between subjects with NHA and IHA. Impaired performance on the prospective memory task during hypoglycaemia demonstrates that recall is disrupted by hypoglycaemia. Impaired performance on the conventional memory tasks demonstrates that learning is also disrupted by hypoglycaemia. Results of the prospective memory task support the relevance of these findings to the everyday lives of people with diabetes.

  1. Freight Wing Trailer Aerodynamics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Graham, Sean; Bigatel, Patrick

    2004-10-17

    Freight Wing Incorporated utilized the opportunity presented by this DOE category one Inventions and Innovations grant to successfully research, develop, test, patent, market, and sell innovative fuel and emissions saving aerodynamic attachments for the trucking industry. A great deal of past scientific research has demonstrated that streamlining box shaped semi-trailers can significantly reduce a truck's fuel consumption. However, significant design challenges have prevented past concepts from meeting industry needs. Market research early in this project revealed the demands of truck fleet operators regarding aerodynamic attachments. Products must not only save fuel, but cannot interfere with the operation of the truck,more » require significant maintenance, add significant weight, and must be extremely durable. Furthermore, SAE/TMC J1321 tests performed by a respected independent laboratory are necessary for large fleets to even consider purchase. Freight Wing used this information to create a system of three practical aerodynamic attachments for the front, rear and undercarriage of standard semi trailers. SAE/TMC J1321 Type II tests preformed by the Transportation Research Center (TRC) demonstrated a 7% improvement to fuel economy with all three products. If Freight Wing is successful in its continued efforts to gain market penetration, the energy and environmental savings would be considerable. Each truck outfitted saves approximately 1,100 gallons of fuel every 100,000 miles, which prevents over 12 tons of CO2 from entering the atmosphere. If all applicable trailers used the technology, the country could save approximately 1.8 billion gallons of diesel fuel, 18 million tons of emissions and 3.6 billion dollars annually.« less

  2. Preserved hyperaemic response in supraclavicular ultrasonography demonstrates function on demand of the LIMA to LAD string sign graft after CABG.

    PubMed

    Hartman, J M; Kelder, H C; Ackerstaff, R G A; Swieten, H A; Vermeulen, F E E; Bogers, A J J C

    2007-02-01

    To correlate supraclavicular ultrasonography with angiographically patent and string sign left internal mammary artery (LIMA) to left anterior descending artery (LAD) grafts. Sixteen patients with a single LIMA anastomosis to the LAD were prospectively entered in a follow-up study. The supraclavicular ultrasonography of the LIMA origin was studied preoperatively and at 5.3+/-3.6 months and 1.7+/-0.4 year postoperatively. At the late postoperative ultrasonography electrocardiographically controlled hyperemic response was also studied for 6 min. Control angiography was performed at 1.5+/-0.8 year. Differences within groups were tested with a paired t-test and between groups with an unpaired t-test. Control angiography showed in 13 patients (group I) a patent LIMA graft and in 3 patients (group II) a string sign LIMA graft. Preoperative blood velocities were not significantly different between groups. Postoperatively, both groups revealed higher diastolic and lower systolic blood velocities compared to preoperative values. The blood velocities at rest did not change in group I and all velocities decreased in group II in time postoperatively. The blood velocities in maximal hyperemic response increased significantly within the groups and were not significantly different between the groups. No ischemia could be detected electrocardiographically during hyperemic response and no patient presented angina. Both groups showed a shift towards coronary type diastolic blood velocities at rest and at hyperaemic response. Significant hyperemic response was also present in string sign LIMA grafts and demonstrates response capacity to increased myocardial oxygen demand.

  3. Motion analysis of throwing Boccia balls in children with cerebral palsy.

    PubMed

    Huang, Po-Chang; Pan, Po-Jung; Ou, Yu-Chih; Yu, Yi-Chen; Tsai, Yung-Shen

    2014-02-01

    Boccia is a sport suitable for children with cerebral palsy (CP). Throwing Boccia balls requires upper extremity and torso coordination. This study investigated the differences between children with CP and normally developed children regarding throwing patterns of Boccia balls. Thirteen children with bilateral spastic CP and 20 normally developed children participated in this study. The tests in this study were a pediatric reach test and throwing of Boccia balls. A 3D electromagnetic motion tracking system and a force plate were synchronized to record and analyze biomechanical parameters of throwing Boccia balls. The results of the pediatric reach test for participants with CP were significantly worse than those for normally developed participants. The 2 groups of participants did not significantly differ regarding the distance between a thrown Boccia ball and a target ball (jack). Participants with CP demonstrated significantly longer movement duration, smaller amplitude of elbow movement, greater amplitudes of shoulder abduction and flexion, slower maximal velocity of torso flexion and the linear velocity of moving the wrist joint forward, faster maximal velocity of head flexion, and smaller sway ratio compared with normally developed participants when throwing Boccia balls. Participants with CP seemed to mainly use head and shoulder movements to bring the Boccia balls forward with limited torso movement. Normally developed participants brought the Boccia ball forward with faster torso and greater elbow movement while stabilizing head and shoulder movements. Nevertheless, participants with CP did not demonstrate significantly worse performance in the throwing accuracy of Boccia balls. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. The impact of culture and education on non-verbal neuropsychological measurements: a critical review.

    PubMed

    Rosselli, Mónica; Ardila, Alfredo

    2003-08-01

    Clinical neuropsychology has frequently considered visuospatial and non-verbal tests to be culturally and educationally fair or at least fairer than verbal tests. This paper reviews the cross-cultural differences in performance on visuoperceptual and visuoconstructional ability tasks and analyzes the impact of education and culture on non-verbal neuropsychological measurements. This paper compares: (1) non-verbal test performance among groups with different educational levels, and the same cultural background (inter-education intra-culture comparison); (2) the test performance among groups with the same educational level and different cultural backgrounds (intra-education inter-culture comparisons). Several studies have demonstrated a strong association between educational level and performance on common non-verbal neuropsychological tests. When neuropsychological test performance in different cultural groups is compared, significant differences are evident. Performance on non-verbal tests such as copying figures, drawing maps or listening to tones can be significantly influenced by the individual's culture. Arguments against the use of some current neuropsychological non-verbal instruments, procedures, and norms in the assessment of diverse educational and cultural groups are discussed and possible solutions to this problem are presented.

  5. Improved pressure measurement system for calibration of the NASA LeRC 10x10 supersonic wind tunnel

    NASA Technical Reports Server (NTRS)

    Blumenthal, Philip Z.; Helland, Stephen M.

    1994-01-01

    This paper discusses a method used to provide a significant improvement in the accuracy of the Electronically Scanned Pressure (ESP) Measurement System by means of a fully automatic floating pressure generating system for the ESP calibration and reference pressures. This system was used to obtain test section Mach number and flow angularity measurements over the full envelope of test conditions for the 10 x 10 Supersonic Wind Tunnel. The uncertainty analysis and actual test data demonstrated that, for most test conditions, this method could reduce errors to about one-third to one-half that obtained with the standard system.

  6. A Cycle Ergometer Exercise Program Improves Exercise Capacity and Inspiratory Muscle Function in Hospitalized Patients Awaiting Heart Transplantation: a Pilot Study

    PubMed Central

    Forestieri, Patrícia; Guizilini, Solange; Peres, Monique; Bublitz, Caroline; Bolzan, Douglas W.; Rocco, Isadora S.; Santos, Vinícius B.; Moreira, Rita Simone L.; Breda, João R.; de Almeida, Dirceu R.; Carvalho, Antonio Carlos de C.; Arena, Ross; Gomes, Walter J.

    2016-01-01

    Objective The purpose of this study was to evaluate the effect of a cycle ergometer exercise program on exercise capacity and inspiratory muscle function in hospitalized patients with heart failure awaiting heart transplantation with intravenous inotropic support. Methods Patients awaiting heart transplantation were randomized and allocated prospectively into two groups: 1) Control Group (n=11) - conventional protocol; and 2) Intervention Group (n=7) - stationary cycle ergometer exercise training. Functional capacity was measured by the six-minute walk test and inspiratory muscle strength assessed by manovacuometry before and after the exercise protocols. Results Both groups demonstrated an increase in six-minute walk test distance after the experimental procedure compared to baseline; however, only the intervention group had a significant increase (P=0.08 and P=0.001 for the control and intervention groups, respectively). Intergroup comparison revealed a greater increase in the intervention group compared to the control (P<0.001). Regarding the inspiratory muscle strength evaluation, the intragroup analysis demonstrated increased strength after the protocols compared to baseline for both groups; statistical significance was only demonstrated for the intervention group, though (P=0.22 and P<0.01, respectively). Intergroup comparison showed a significant increase in the intervention group compared to the control (P<0.01). Conclusion Stationary cycle ergometer exercise training shows positive results on exercise capacity and inspiratory muscle strength in patients with heart failure awaiting cardiac transplantation while on intravenous inotropic support. PMID:27982348

  7. Multicyclic Controllable Twist Rotor Data Analysis

    NASA Technical Reports Server (NTRS)

    Wei, F. S.; Weisbrich, A. L.

    1979-01-01

    Rsults provide functional relationship between rotor performance, blade vibratory loads and dual control settings and indicate that multicyclic control produced significant reductions in blade flatwise bending moments and blade root actuator control loads. Higher harmonic terms of servo flap deflection were found to be most pronounced in flatwise bending moment, transmission vertical vibration and pitch link vibratory load equations. The existing test hardware represents a satisfactory configuration for demonstrating MCTR technology and defining a data base for additional wind tunnel testing.

  8. Rivastigmine but not vardenafil reverses cannabis-induced impairment of verbal memory in healthy humans.

    PubMed

    Theunissen, E L; Heckman, P; de Sousa Fernandes Perna, E B; Kuypers, K P C; Sambeth, A; Blokland, A; Prickaerts, J; Toennes, S W; Ramaekers, J G

    2015-01-01

    One of the most often reported cognitive deficits of acute cannabis administration is an impaired recall of previously learned information. The aim of the present study was to determine whether cannabis-induced memory impairment in humans is mediated via glutamatergic or cholinergic pathways. Fifteen occasional cannabis users participated in a double-blind, placebo-controlled, six-way cross-over study. On separate test days, subjects received combinations of pretreatment (placebo, vardenafil 20 mg or rivastigmine 3 mg) and treatment (placebo or 1,376 mg cannabis/kg body weight). Cognitive tests were administered immediately after inhalation of treatment was finished and included measures of memory (visual verbal learning task, prospective memory test, Sternberg memory test), perceptual-motor control (critical tracking task), attention (divided attention task) and motor impulsivity (stop signal task). The results of this study demonstrate that subjects under the influence of cannabis were impaired in all memory tasks, in critical tracking, divided attention and the stop signal task. Pretreatment with rivastigmine attenuated the effect of cannabis on delayed recall and showed a trend towards significance on immediate recall. When cannabis was given in combination with vardenafil, there were no significant interaction effects in any of the tasks. The present data therefore suggest that acetylcholine plays an important role in cannabis-induced memory impairment, whereas similar results for glutamate have not been demonstrated in this study.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kahl, S.B.

    Although significant progress toward the application of boronated LDL for site selective boron drug delivery has been made during the past year, the loss of our animal and cell culture testing site at WSU has seriously hampered progress on this project. Results are reported of one in vivo biodistribution study in B16BL6-bearing mice and a series of in vitro studies that demonstrate very substantial uptake of boronated LDL in certain cell lines. The influence of 17{alpha}-ethinyl estradiol (EE) on cellular uptake has also been probed. Most significantly LDL loaded with HC was demonstrated to be taken up with exceptional ariditymore » in several lines. Significant progress has also been made in the development of a rapid infrared analysis of boron in boronated LDL solution, which may be useful for clinical BNCT studies in Finland.« less

  10. Prevalence of neurocognitive and balance deficits in collegiate aged football players without clinically diagnosed concussion.

    PubMed

    Mulligan, Ivan; Boland, Mark; Payette, Justin

    2012-07-01

    Prospective cohort. To identify the prevalence of neurocognitive and balance deficits in collegiate football players 48 hours following competition. Neurocognitive testing, balance assessments, and subjective report of symptoms are a commonly used test battery in examining athletes when concussion is suspected. Previous literature suggests many concussions go unreported. Little research exists examining the prevalence of neurocognitive or balance deficits in athletes who do not report concussion-like symptoms to a health care provider. Forty-five Division IA collegiate football players participated in this study. Preseason baseline scores using the Balance Error Scoring System, the Immediate Post-Concussion Assessment and Cognitive Testing, and the Postconcussion Symptom Scale were compared to posttest results obtained 48 hours following a game. Prevalence of symptoms was analyzed and reported. Thirty-two (71%) of the 45 athletes tested demonstrated at least 1 deficit in either the Postconcussion Symptom Scale, Balance Error Scoring System, or at least 1 composite score of the Immediate Post-Concussion Assessment and Cognitive Testing. Nineteen of the 32 subjects demonstrated a change in 2 or more categories of neurocognitive and balance function. In a cohort of football players tested 48 hours following their last game of the season, who did not seek medical attention related to a concussion, a significant number demonstrated limitations in neurocognitive and balance performance, suggesting that further research may need to be performed to improve recognition of an athlete's deficits and to improve the ability to assess concussion. Differential diagnosis/symptom prevalence, level 3b.

  11. Subliminal or not? Comparing null-hypothesis and Bayesian methods for testing subliminal priming.

    PubMed

    Sand, Anders; Nilsson, Mats E

    2016-08-01

    A difficulty for reports of subliminal priming is demonstrating that participants who actually perceived the prime are not driving the priming effects. There are two conventional methods for testing this. One is to test whether a direct measure of stimulus perception is not significantly above chance on a group level. The other is to use regression to test if an indirect measure of stimulus processing is significantly above zero when the direct measure is at chance. Here we simulated samples in which we assumed that only participants who perceived the primes were primed by it. Conventional analyses applied to these samples had a very large error rate of falsely supporting subliminal priming. Calculating a Bayes factor for the samples very seldom falsely supported subliminal priming. We conclude that conventional tests are not reliable diagnostics of subliminal priming. Instead, we recommend that experimenters calculate a Bayes factor when investigating subliminal priming. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  12. Influence of container adsorption upon observed pyrethroid toxicity to Ceriodaphnia dubia and Hyalella azteca

    PubMed Central

    Wheelock, Craig E.; Miller, Jeff L.; Miller, Mike J.; Phillips, Bryn M.; Gee, Shirley J.; Tjeerdema, Ronald S.; Hammock, Bruce D.

    2006-01-01

    Pyrethroid insecticides are known for their potential toxicity to aquatic invertebrates and many fish species. A significant problem in the study of pyrethroid toxicity is their extreme hydrophobicity. They can adsorb to test container surfaces and many studies, therefore, report pyrethroid levels as nominal water concentrations. In this study, pyrethroid adsorption to sampling and test containers was measured and several container treatments were examined for their ability to decrease pyrethroid adsorption. None of the chemical treatments were successful at preventing pyrethroid loss from aqueous samples, but vortexing of containers served to resuspend pyrethroids. The effects of the observed adsorption on Ceriodaphnia dubia and Hyalella azteca permethrin toxicity were examined. Species-specific results showed a time-dependent decrease in toxicity following pyrethroid adsorption to test containers for C. dubia, but not for H. azteca. These results demonstrate that pyrethroid adsorption to containers can significantly affect the observed outcome in toxicity-testing and serves as a caution for researchers and testing laboratories. PMID:15951033

  13. The Girlfriends Project: Results of a pilot study assessing feasibility of an HIV testing and risk reduction intervention developed, implemented, and evaluated in community settings.

    PubMed

    Hawk, Mary

    2013-12-01

    African American women in the United States experience significant HIV health disparities. The majority of evidence-based risk reduction interventions do not incorporate HIV testing, and most are targeted only to narrow segments of the population such as women who are pregnant or seen in STI clinics. This pilot study assessed the feasibility and efficacy of The Girlfriends Project (TGP), a community developed and community evaluated HIV risk reduction and testing intervention. A group randomized wait-list design was used to recruit 149 women and to compare findings for intervention group versus control group participants. Women in the intervention group demonstrated statistically-significant increases in HIV knowledge scores and in condom use during vaginal sex. Eighty-seven percent of participants accessed HIV testing with a 100% return rate for results. Study findings suggest that TGP has the potential to be an effective intervention and to increase number of African American women who access HIV testing.

  14. Lunar Simulants, Analogues, and Standards: Needs and Realities for Mission Technologies Development

    NASA Technical Reports Server (NTRS)

    Sibille, Laurent

    2013-01-01

    Integration of In-Situ Resource Utilization (ISRU) capabilities into missions present both challenges as well as benefits for future missions to the Moon and Mars. However, since ISRU systems and capabilities have not flown, mission planners have been hesitant to include ISRU capabilities in mission critical roles, thereby significantly reducing the benefits that ISRU can provide in mission mass and cost reductions. For ISRU systems to provide products and services to 'customers' such as life support, propulsion, and power systems, close development of requirements, hardware, and operations between ISRU and these systems are required. To address these development and incorporation challenges, NASA and csA initiated a series of analog field test demonstrations at sites in Hawaii. Two tests completed in November of 2008 and February of 2010 have demonstrate all the critical steps in operating ISRU systems on the lunar surface at relevant mission scales as well as integration with power and propulsion systems. The third field test planned for July 2012 will demonstrate that a mission to the lunar poles to locate and characterize ice and other volatiles is possible in a highly integrated mission with multiple space agencies. These analog field tests have shown that not only are ISRU systems feasible at relevant mission scales, that they can be successfully integrated into mission architectures.

  15. Eagle-Picher Industries Sodium Sulfur Program

    NASA Technical Reports Server (NTRS)

    Silvey, Ronald L.

    1993-01-01

    Viewgraphs of the sodium sulfur program are presented. Sodium sulfur low earth orbit (LEO) cells are described. Topics covered include cell sizes, areas of improvement, and NaS cell testing. Sodium sulfur cell and battery designs continue to evolve with significant improvement demonstrated in resistance, rechargeability, cycle life, energy density, and electrolyte characterization.

  16. The Democratization of the Oncogene

    PubMed Central

    Le, Anh T.; Doebele, Robert C.

    2014-01-01

    Summary The identification of novel, oncogenic gene rearrangements in inflammatory myofibroblastic tumor (IMT) demonstrates the potential of next generation sequencing (NGS) platforms for the detection of therapeutically relevant oncogenes across multiple tumor types, but raises significant questions relating to the investigation of targeted therapies in this new era of widespread NGS testing. PMID:25092743

  17. Paired Associate Learning in Chinese Children with Dyslexia

    ERIC Educational Resources Information Center

    Li, Hong; Shu, Hua; McBride-Chang, Catherine; Liu, Hong Yun; Xue, Jin

    2009-01-01

    A total of 82 Chinese 11- and 12-year-olds with and without dyslexia were tested on four paired associate learning (PAL) tasks, phonological awareness, morphological awareness, rapid naming, and verbal short-term memory in three different experiments. Experiment 1 demonstrated that children with dyslexia were significantly poorer in visual-verbal…

  18. Principals and the Politics of Resistance to Change

    ERIC Educational Resources Information Center

    Starr, Karen

    2011-01-01

    Governments hold principals accountable for leading and managing significant change for school improvement, primarily demonstrated through enhanced student test results. Research evidence suggests, however, that schools are slow to change, that many individuals are resistant to major change and that school reforms are often cursory or short lived.…

  19. Effects of grass competition on bitterbrush: second-year report

    Treesearch

    H. Reed Sanderson; Richard L. Hubbard; Donald W. Seegrist

    1963-01-01

    The second year's data of a study designed to test the effects of perennial grass competition on the vigor of bitterbrush (Purshia tridentata) in an area of heavy bitterbrush mortality are reported. The data demonstrated that competition from other plants, mainly perennial grass, significantly reduced bitterbrush growth.

  20. Aconitine Challenge Test Reveals a Single Exposure to Air Pollution Causes Increased Cardiac Arrhythmia Risk in Hypertensive Rats - Abstract

    EPA Science Inventory

    Epidemiological studies demonstrate a significant association between arrhythmias and air pollution exposure. Sensitivity to aconitine-induced arrhythmia has been used repeatedly to examine the factors that increase the risk of such cardiac electrical dysfunction. In this study, ...

  1. DOMINANT LETHAL EFFECTS OF SUBCHRONIC ACRYLAMIDE ADMINISTRATION IN THE MALE LONG-EVANS RAT

    EPA Science Inventory

    Acrylamide, a widely used vinyl monomer, is well known as a neurotoxin but inactive as a mutagen in bacterial test systems. The experiments reported demonstrate that after subchronic oral dosing in the male rat, acrylamide induced significant elevations in both pre and post impla...

  2. SOME RESULTS FROM THE DEMONSTRATION OF INDOOR RADON REDUCTION MEASURES IN BLOCK BASEMENT HOUSES

    EPA Science Inventory

    Active soil ventilation techniques have been tested in 26 block-wall basement houses in eastern Pennsylvania with significantly elevated indoor radon concentrations, generally above 740 Bq/m3, and the results indicate that radon levels can be reduced substantially often below the...

  3. Revisiting the role of recollection in item versus forced-choice recognition memory.

    PubMed

    Cook, Gabriel I; Marsh, Richard L; Hicks, Jason L

    2005-08-01

    Many memory theorists have assumed that forced-choice recognition tests can rely more on familiarity, whereas item (yes-no) tests must rely more on recollection. In actuality, several studies have found no differences in the contributions of recollection and familiarity underlying the two different test formats. Using word frequency to manipulate stimulus characteristics, the present study demonstrated that the contributions of recollection to item versus forced-choice tests is variable. Low word frequency resulted in significantly more recollection in an item test than did a forced-choice procedure, but high word frequency produced the opposite result. These results clearly constrain any uniform claim about the degree to which recollection supports responding in item versus forced-choice tests.

  4. Schizophrenia patients demonstrate a dissociation on declarative and non-declarative memory tests.

    PubMed

    Perry, W; Light, G A; Davis, H; Braff, D L

    2000-12-15

    Declarative memory refers to the recall and recognition of factual information. In contrast, non-declarative memory entails a facilitation of memory based on prior exposure and is typically assessed with priming and perceptual-motor sequencing tasks. In this study, schizophrenia patients were compared to normal comparison subjects on two computerized memory tasks: the Word-stem Priming Test (n=30) and the Pattern Sequence Learning Test (n=20). Word-stem Priming includes recall, recognition (declarative) and priming (non-declarative) components of memory. The schizophrenia patients demonstrated an impaired performance on recall of words with relative improvement during the recognition portion of the test. Furthermore, they performed normally on the priming portion of the test. Thus, on tests of declarative memory, the patients had retrieval deficits with intact performance on the non-declarative memory component. The Pattern Sequence Learning Test utilizes a serial reaction time paradigm to assess non-declarative memory. The schizophrenia patients' serial reaction time was significantly slower than that of comparison subjects. However, the patients' rate of acquisition was not different from the normal comparison group. The data suggest that patients with schizophrenia process more slowly than normal, but have an intact non-declarative memory. The schizophrenia patients' dissociation on declarative vs. non-declarative memory tests is discussed in terms of possible underlying structural impairment.

  5. Comparison of FibroTest-ActiTest with histopathology in demonstrating fibrosis and necroinflammatory activity in chronic hepatitis B and C.

    PubMed

    Uyar, Cemile; Akcam, Fusun Zeynep; Ciris, Metin; Kaya, Onur; Kockar, Cem; Isler, Mehmet

    2010-01-01

    FibroTest and ActiTest are noninvasive tests used in determining the level of fibrosis and the degree of necroinflammatory activity in the liver. In our study, we aimed to investigate whether these tests could be alternative to liver biopsy. Fifty patients were included in the study. Serum samples were obtained and liver needle biopsy was performed on the same day. Levels of fibrosis in FibroTest and levels of activity in ActiTest, both determined via serum biochemical markers, were compared with levels of fibrosis and activity in histopathological examination. For statistical analyses, Mc Nemar chi square test and Spearman's correlation tests were used. There was a significant positive correlation between fibrosis in biopsy and the level of fibrosis in FibroTest in patients with hepatitis B virus (HBV) (rho: 0.67, P < 0.0001). However, no significant correlation was determined between the activity in biopsy and the degree of activity in ActiTest (rho: 0.29, P < 0.05). No significant correlation was determined between both fibrosis and activity established in biopsy and the results of FibroTest and ActiTest in the group of patients with hepatitis C virus (HCV) (rho: 0.22, P < 0.05 and rho: 0.15, P < 0.05, respectively). Our results suggest that novel and safer noninvasive biochemical tests are needed as an alternative to histopathology in patients infected with HBV and HCV. Consequently, we believe that liver biopsy maintains its place as a gold standard in determining the histopathological condition of the liver.

  6. An Evaluation of Liquid, Solid, and Grease Lubricants for Space Mechanisms Using a Spiral Orbit Tribometer

    NASA Technical Reports Server (NTRS)

    Buttery, Michael

    2010-01-01

    We present the findings of the test program performed by The European Space Tribology Laboratory (ESTL) to evaluate the performance (friction and lifetime) of a number of space lubricants under vacuum using a Spiral Orbit Tribometer (SOT). Focus was given to a comparison of various popular space oils, a comparison study between the old and new MAPLUB grease formulations, and the performance of commonly used solid lubricants under various conditions. Tests demonstrated that the lifetimes of hydrocarbon NYE oils 2001 & 2001A outperformed those of the perfluroropolyalkylether (PFPE) oils Fomblin Z25 & Z60, though these pairs displayed similar behavior. This relationship was also generally seen for greases; with the lifetimes of the multiple alkylated cyclopentane (MAC)-based greases being extended in comparison to the PFPE-based greases. Testing on greases also demonstrated similar performance between the old (-a) and new (-b) formulations when considering PFPE-based MAPLUB greases, and indeed for all tested PFPE-based non-MAPLUB greases, but significantly shorter lifetimes for the new formulations when considering MAC-based MAPLUB greases. MAPLUB MAC greases containing molybdenum disulphide (MoS2) thickener were also found to display reduced lifetimes. For solid lubricants, lead displayed significantly extended lifetimes over MoS2, speculated to be caused by redistribution of lead from the ball onto all contact surfaces during the test. Friction coefficients were seen to be some 2.5x higher for lead than for MoS2 under similar conditions, a result that corresponds well with conventional bearing tests. The work described was performed under contract for the European Space Agency as part of the Tribology Applications Program, with all funding for testing and apparatus provided by European Space Agency (ESA).

  7. The effect of Nigella sativa Linn. seed on memory, attention and cognition in healthy human volunteers.

    PubMed

    Bin Sayeed, Muhammad Shahdaat; Asaduzzaman, Md; Morshed, Helal; Hossain, Md Monir; Kadir, Mohammad Fahim; Rahman, Md Rezowanur

    2013-07-30

    Experimental evidences have demonstrated that Nigella sativa Linn. seed (NS) has positive modulation effects on aged rats with memory impairments, prevents against hippocampal pyramidal cell loss and enhances consolidation of recall capability of stored information and spatial memory in rats. NS has neuroprotective, nephroprotective, lung protective, cardioprotective, hepatoprotective activities as established by previous studies on animals. Several clinical trials with NS on human have also demonstrated beneficial effect. The present study was designed to investigate the effects of NS on memory, attention and cognition in healthy elderly volunteers. Furthermore, safety profile of NS was assessed during the nine-week study period. Forty elderly volunteers were recruited and divided randomly into group A and group B--each consisting of 20 volunteers. The treatment procedure for group A was 500 mg NS capsule twice daily for nine weeks and Group B received placebo instead of NS in the similar manner. All the volunteers were assessed for neuropsychological state and safety profile twice before treatment and after nine weeks. The neuropsychological tests were logical memory test, digit span test, Rey-Osterrieth complex figure test, letter cancellation test, trail making test and stroop test. Safety profile was assessed by measuring biochemical markers of Cardiac (total cholesterol, triglycerides and high density lipoprotein cholesterol, very low density lipoprotein, low density lipoprotein cholesterol, creatine kinase-MB); Liver (aspartate aminotransferase, alanin aminotransferase, alkaline phosphatase, total protein, albumin, bilirubin) and Kidney (creatinine and blood urea nitrogen) through using commercial kits. There was significant difference (p<0.05) in the score of logical memory test-I and II, total score of digit span, 30 min delayed-recall, percent score in Rey-Osterrieth complex figure test, time taken to complete letter cancellation test, time taken in trail making test-A and test-B, score in part C of stroop test due to ingestion of NS for nine weeks. There were not statistically significant changes (p>0.05) in any of the biochemical markers of cardiac, liver, kidney function during this nine-week study period. The current study demonstrates the role of NS in enhancing memory, attention and cognition. Therefore, whether NS could be considered as potential food supplement for preventing or slow progressing of Alzheimer disease needs further investigations. However, study with Alzheimer's patients with large population size for longer period of time is recommended before using NS daily and extensive phytochemical investigations are recommended for novel drug discovery from NS for treating cognitive disorders. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  8. Composite transport wing technology development: Design development tests and advanced structural concepts

    NASA Technical Reports Server (NTRS)

    Griffin, Charles F.; Harvill, William E.

    1988-01-01

    Numerous design concepts, materials, and manufacturing methods were investigated for the covers and spars of a transport box wing. Cover panels and spar segments were fabricated and tested to verify the structural integrity of design concepts and fabrication techniques. Compression tests on stiffened panels demonstrated the ability of graphite/epoxy wing upper cover designs to achieve a 35 percent weight savings compared to the aluminum baseline. The impact damage tolerance of the designs and materials used for these panels limits the allowable compression strain and therefore the maximum achievable weight savings. Bending and shear tests on various spar designs verified an average weight savings of 37 percent compared to the aluminum baseline. Impact damage to spar webs did not significantly degrade structural performance. Predictions of spar web shear instability correlated well with measured performance. The structural integrity of spars manufactured by filament winding equalled or exceeded those fabricated by hand lay-up. The information obtained will be applied to the design, fabrication, and test of a full-scale section of a wing box. When completed, the tests on the technology integration box beam will demonstrate the structural integrity of an advanced composite wing design which is 25 percent lighter than the metal baseline.

  9. A historical perspective of the YF-12A thermal loads and structures program

    NASA Technical Reports Server (NTRS)

    Jenkins, Jerald M.; Quinn, Robert D.

    1996-01-01

    Around 1970, the Y-F-12A loads and structures efforts focused on numerous technological issues that needed defining with regard to aircraft that incorporate hot structures in the design. Laboratory structural heating test technology with infrared systems was largely created during this program. The program demonstrated the ability to duplicate the complex flight temperatures of an advanced supersonic airplane in a ground-based laboratory. The ability to heat and load an advanced operational aircraft in a laboratory at high temperatures and return it to flight status without adverse effects was demonstrated. The technology associated with measuring loads with strain gages on a hot structure was demonstrated with a thermal calibration concept. The results demonstrated that the thermal stresses were significant although the airplane was designed to reduce thermal stresses. Considerable modeling detail was required to predict the heat transfer and the corresponding structural characteristics. The overall YF-12A research effort was particularly productive, and a great deal of flight, laboratory, test and computational data were produced and cross-correlated.

  10. Microbiologic evaluation of microfiber mops for surface disinfection.

    PubMed

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-11-01

    Recently, health care facilities have started to use a microfiber mopping technique rather than a conventional, cotton string mop to clean floors. The effectiveness of microfiber mops to reduce microbial levels on floors was investigated. We compared the efficacy of microfiber mops with that of conventional, cotton string mops in 3 test conditions (cotton mop and standard wringer bucket, microfiber mop and standard wringer bucket, microfiber system). Twenty-four rooms were evaluated for each test condition. RODAC plates containing D/E Neutralizing Agar were used to assess "precleaning" and "postcleaning" microbial levels. The microfiber system demonstrated superior microbial removal compared with cotton string mops when used with a detergent cleaner (95% vs 68%, respectively). The use of a disinfectant did not improve the microbial elimination demonstrated by the microfiber system (95% vs 95%, respectively). However, use of disinfectant did significantly improve microbial removal when a cotton string mop was used (95% vs 68%, respectively). The microfiber system demonstrated superior microbial removal compared with cotton string mops when used with a detergent cleaner. The use of a disinfectant did not improve the microbial elimination demonstrated by the microfiber system.

  11. Arterial Pulsations cannot Drive Intramural Periarterial Drainage: Significance for Aβ Drainage

    PubMed Central

    Diem, Alexandra K.; MacGregor Sharp, Matthew; Gatherer, Maureen; Bressloff, Neil W.; Carare, Roxana O.; Richardson, Giles

    2017-01-01

    Alzheimer's Disease (AD) is the most common form of dementia and to date there is no cure or efficient prophylaxis. The cognitive decline correlates with the accumulation of amyloid-β (Aβ) in the walls of capillaries and arteries. Our group has demonstrated that interstitial fluid and Aβ are eliminated from the brain along the basement membranes of capillaries and arteries, the intramural periarterial drainage (IPAD) pathway. With advancing age and arteriosclerosis, the stiffness of arterial walls, this pathway fails in its function and Aβ accumulates in the walls of arteries. In this study we tested the hypothesis that arterial pulsations drive IPAD and that a valve mechanism ensures the net drainage in a direction opposite to that of the blood flow. This hypothesis was tested using a mathematical model of the drainage mechanism. We demonstrate firstly that arterial pulsations are not strong enough to produce drainage velocities comparable to experimental observations. Secondly, we demonstrate that a valve mechanism such as directional permeability of the IPAD pathway is necessary to achieve a net reverse flow. The mathematical simulation results are confirmed by assessing the pattern of IPAD in mice using pulse modulators, showing no significant alteration of IPAD. Our results indicate that forces other than the cardiac pulsations are responsible for efficient IPAD. PMID:28883786

  12. Efficacy of terbinafine compared to lanoconazole and luliconazole in the topical treatment of dermatophytosis in a guinea pig model.

    PubMed

    Ghannoum, M A; Long, L; Kim, H G; Cirino, A J; Miller, A R; Mallefet, P

    2010-05-01

    The in vivo efficacy of terbinafine was compared to lanoconazole and luliconazole in the topical treatment of dermatophytosis caused by Trichophyton mentagrophytes using a guinea pig model. Topical antifungal treatment commenced three days post-infection, and each agent was applied once daily for seven consecutive days. Upon completion of the treatment period, evaluations of clinical and mycological efficacies were performed, as was scanning electron microscopy (SEM) analyses. Data showed that while all tested antifungals demonstrated significant mycological efficacy in terms of eradicating the fungi over untreated control, terbinafine and luliconazole showed superior clinical efficacy compared to lanoconazole (P-values < 0.001 & 0.003, respectively). Terbinafine demonstrated the highest clinical percent efficacy. SEM analysis revealed hairs from terbinafine and lanoconazole-treated animals had near complete clearance of fungi, while samples from luliconazole-treated animals were covered with debris and few conidia. This study demonstrates that, in general, terbinafine possessed similar efficacy to lanoconazole and luliconazole in the treatment of dermatophytosis. Terbinafine tended to have superior clinical efficacy compared to the azoles tested, although this difference was not statistically significant against luliconazole. This apparent superiority may be due to the fungicidal activity of terbinafine compared to the fungistatic effect of the other two drugs.

  13. Content and retention evaluation of an audiovisual patient-education program on bronchodilators.

    PubMed

    Darr, M S; Self, T H; Ryan, M R; Vanderbush, R E; Boswell, R L

    1981-05-01

    A study was conducted to: (1) evaluate the effect of a slide-tape program on patients' short-term and long-term knowledge about their bronchodilator medications; and (2) determine it any differences exist in learning or retention patterns for different content areas of drug information. The knowledge of 30 patients was measured using a randomized sequence of three comparable 15-question tests. The first test was given before the slide-tape program was presented, the second test within 24 hours, and the last test one to six months (mean = 2.8 months) later. Scores attained on the first posttest were significantly higher (p less than 0.001) than pretest scores. Learning differences among drug-information-content areas were not evidenced on the first posttest. No significant difference was demonstrated between scores on pretest and last posttest (p = 0.100). However, retention patterns among content areas were found to differ significantly (p less than 0.05). Carefully designed audiovisual programs can impart drug information to patients. Medication counseling should be repeated at appropriate opportunities because patients lose drug knowledge over time.

  14. Ground and flight test results of a total main rotor isolation system

    NASA Technical Reports Server (NTRS)

    Halwes, Dennis R.

    1987-01-01

    A six degree-of-freedom (DOF) isolation system using six LIVE units has been installed under an Army/NASA contract on a Bell 206LM helicopter. This system has been named the Total Rotor Isolation System, or TRIS. To determine the effectiveness of TRIS in reducing helicopter vibration, a flight verification study was conducted at Bell's Flight Research Center in Arlington, Texas. The flight test data indicate that the 4/rev vibration level at the pilot's seat were suppressed below the 0.04g level throughout the transition envelope. Flight tests indicate over 95% suppression of vibration level from the rotor hub to the pilot's seat. The TRIS installation was designed with a decoupled control system and has shown a significant improvement in aircraft flying qualities, such that it permitted the trimmed aircraft to be flown hands-off for a significant period of time, over 90 seconds. The TRIS flight test program has demonstrated a system that greatly reduces vibration levels of a current-generation helicopter, while significantly improving the flying qualities to a point where stability augmentation is no longer a requirement.

  15. Ambiguity in measuring matrix diffusion with single-well injection/recovery tracer tests

    USGS Publications Warehouse

    Lessoff, S.C.; Konikow, Leonard F.

    1997-01-01

    Single-well injection/recovery tracer tests are considered for use in characterizing and quantifying matrix diffusion in dual-porosity aquifers. Numerical modeling indicates that neither regional drift in homogeneous aquifers, nor heterogeneity in aquifers having no regional drift, nor hydrodynamic dispersion significantly affects these tests. However, when drift is coupled simultaneously with heterogeneity, they can have significant confounding effects on tracer return. This synergistic effect of drift and heterogeneity may help explain irreversible flow and inconsistent results sometimes encountered in previous single-well injection/recovery tracer tests. Numerical results indicate that in a hypothetical single-well injection/recovery tracer test designed to demonstrate and measure dual-porosity characteristics in a fractured dolomite, the simultaneous effects of drift and heterogeneity sometimes yields responses similar to those anticipated in a homogeneous dual-porosity formation. In these cases, tracer recovery could provide a false indication of the occurrence of matrix diffusion. Shortening the shut-in period between injection and recovery periods may make the test less sensitive to drift. Using multiple tracers having different diffusion characteristics, multiple tests having different pumping schedules, and testing the formation at more than one location would decrease the ambiguity in the interpretation of test data.

  16. Effects of a common transcranial direct current stimulation (tDCS) protocol on motor evoked potentials found to be highly variable within individuals over 9 testing sessions.

    PubMed

    Horvath, Jared Cooney; Vogrin, Simon J; Carter, Olivia; Cook, Mark J; Forte, Jason D

    2016-09-01

    Transcranial direct current stimulation (tDCS) uses a weak electric current to modulate neuronal activity. A neurophysiologic outcome measure to demonstrate reliable tDCS modulation at the group level is transcranial magnetic stimulation engendered motor evoked potentials (MEPs). Here, we conduct a study testing the reliability of individual MEP response patterns following a common tDCS protocol. Fourteen participants (7m/7f) each underwent nine randomized sessions of 1 mA, 10 min tDCS (3 anode; 3 cathode; 3 sham) delivered using an M1/orbito-frontal electrode montage (sessions separated by an average of ~5.5 days). Fifteen MEPs were obtained prior to, immediately following and in 5 min intervals for 30 min following tDCS. TMS was delivered at 130 % resting motor threshold using neuronavigation to ensure consistent coil localization. A number of non-experimental variables were collected during each session. At the individual level, considerable variability was seen among different testing sessions. No participant demonstrated an excitatory response ≥20 % to all three anodal sessions, and no participant demonstrated an inhibitory response ≥20 % to all three cathodal sessions. Intra-class correlation revealed poor anodal and cathodal test-retest reliability [anode: ICC(2,1) = 0.062; cathode: ICC(2,1) = 0.055] and moderate sham test-retest reliability [ICC(2,1) = 0.433]. Results also revealed no significant effect of tDCS at the group level. Using this common protocol, we found the effects of tDCS on MEP amplitudes to be highly variable at the individual level. In addition, no significant effects of tDCS on MEP amplitude were found at the group level. Future studies should consider utilizing a more strict experimental protocol to potentially account for intra-individual response variations.

  17. Factors influencing behavioral intention to undergo Papanicolaou testing in early adulthood: Comparison of Japanese and Korean women.

    PubMed

    Kang, Kyung-Ah; Kim, Shin-Jeong; Kaneko, Noriyo

    2017-12-01

    In this study, we identified the factors influencing behavioral intention to undergo Papanicolaou testing among Japanese and Korean women in early adulthood. Their behavioral intentions were compared in this cross-sectional descriptive study. In total, 887 women (Japanese = 498, Korean = 389) aged 20-39 years participated in this study. Using a self-report questionnaire, knowledge, attitudes, subjective norm, perceived behavioral control, and behavioral intention were surveyed. There were significant differences between Japanese and Korean women's scores on all main variables. For Japanese women, all the variables moderately correlated with behavioral intention. In comparison, for Korean women, all independent variables, except for knowledge, moderately correlated with behavioral intention. Through a multiple regression analysis, age, undergoing Papanicolaou testing, attitudes, subjective norm, and perceived behavioral control were identified as significant predictors of behavioral intention among Japanese women. Among Korean women, job status, undergoing a Papanicolaou test, attitudes, subjective norm, and perceived behavioral control were demonstrated as significant predictors of behavioral intention. Health professionals should consider these factors to encourage Papanicolaou testing in women in early adulthood. © 2017 John Wiley & Sons Australia, Ltd.

  18. Right frontal pole cortical thickness and executive functioning in children with traumatic brain injury: the impact on social problems.

    PubMed

    Levan, Ashley; Black, Garrett; Mietchen, Jonathan; Baxter, Leslie; Brock Kirwan, C; Gale, Shawn D

    2016-12-01

    Cognitive and social outcomes may be negatively affected in children with a history of traumatic brain injury (TBI). We hypothesized that executive function would mediate the association between right frontal pole cortical thickness and problematic social behaviors. Child participants with a history of TBI were recruited from inpatient admissions for long-term follow-up (n = 23; average age = 12.8, average time post-injury =3.2 years). Three measures of executive function, the Trail Making Test, verbal fluency test, and the Conners' Continuous Performance Test-Second edition (CPT-II), were administered to each participant while caregivers completed the Childhood Behavior Checklist (CBCL). All participants underwent brain magnetic resonance imaging following cognitive testing. Regression analysis demonstrated right frontal pole cortical thickness significantly predicted social problems. Measures of executive functioning also significantly predicted social problems; however, the mediation model testing whether executive function mediated the relationship between cortical thickness and social problems was not statistically significant. Right frontal pole cortical thickness and omission errors on the CPT-II predicted Social Problems on the CBCL. Results did not indicate that the association between cortical thickness and social problems was mediated by executive function.

  19. Perceived Risk as a Moderator of the Effectiveness of Framed HIV Test Promotion Messages Among Women: A Randomized Controlled Trial

    PubMed Central

    Hull, Shawnika J

    2014-01-01

    Objective Researchers argue that gain framed messages should be more effective for prevention behaviors while loss frames should be more effective for detection behaviors (Rothman & Salovey, 1997). Evidence for this taxonomy has been mixed. This study examines whether the effects of gain and loss framed messages on HIV testing intentions is moderated by perceived risk of a positive result. Methods This experiment was conducted on-line and utilizes a single factor (frame: gain/loss) between subjects design, with a separate HIV test promotion control and a no message control to examine whether perceived risk of a positive test result moderates the effects of framed messages on intentions to seek an HIV test in the next 3 months. The sample (N=1052; age M = 22, SD = 2.22), recruited through Survey Sampling International, included 51% Black women (49% White women). Results HIV test promotion messages were more effective than no message but there were no other main effects for condition. Results also demonstrate a significant interaction between message frame and perceived risk, which is mediated through elaborative processing of the message. The interaction demonstrated an advantage for the loss framed message among women with some perceived risk and an advantage for the gain framed message among women with low perceived risk. Conclusion Results imply that the prevention/detection function of the behavior may be an inadequate distinction in the consideration of the effectiveness of framed messages promoting HIV testing. Rather, this study demonstrates that risk perceptions are an important moderator of framing effects. PMID:21767018

  20. Perceived risk as a moderator of the effectiveness of framed HIV-test promotion messages among women: a randomized controlled trial.

    PubMed

    Hull, Shawnika J

    2012-01-01

    Researchers argue that gain-framed messages should be more effective for prevention behaviors, while loss frames should be more effective for detection behaviors (Rothman & Salovey, 1997). Evidence for this taxonomy has been mixed. This study examines whether the effects of gain- and loss-framed messages on HIV-testing intentions is moderated by perceived risk of a positive result. This experiment was conducted online and utilized a single factor (frame: gain/loss) between subjects design, with a separate HIV-test promotion control and a no message control to examine whether perceived risk of a positive test result moderates the effects of framed messages on intentions to seek an HIV test in the next 3 months. The sample (N = 1052; M age = 22, SD = 2.22), recruited through Survey Sampling International, included 51% Black women (49% White women). HIV-test promotion messages were more effective than no message, but there were no other main effects for condition. Results also demonstrated a significant interaction between message frame and perceived risk, which is mediated through elaborative processing of the message. The interaction demonstrated an advantage for the loss-framed message among women with some perceived risk and an advantage for the gain-framed message among women with low perceived risk. Results imply that the prevention/detection function of the behavior may be an inadequate distinction in the consideration of the effectiveness of framed messages promoting HIV testing. Rather, this study demonstrates that risk perceptions are an important moderator of framing effects.

  1. Catalytic Combustion for Ultra-Low NOx Hydrogen Turbines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Etemad, Shahrokh; Baird, Benjamin; Alavandi, Sandeep

    2011-06-30

    Precision Combustion, Inc., (PCI) in close collaboration with Solar Turbines, Incorporated, has developed and demonstrated a combustion system for hydrogen fueled turbines that reduces NOx to low single digit level while maintaining or improving current levels of efficiency and eliminating emissions of carbon dioxide. Full scale Rich Catalytic Hydrogen (RCH1) injector was developed and successfully tested at Solar Turbines, Incorporated high pressure test facility demonstrating low single digit NOx emissions for hydrogen fuel in the range of 2200F-2750F. This development work was based on initial subscale development for faster turnaround and reduced cost. Subscale testing provided promising results for 42%more » and 52% H2 with NOx emissions of less than 2 ppm with improved flame stability. In addition, catalytic reactor element testing for substrate oxidation, thermal cyclic injector testing to simulate start-stop operation in a gas turbine environment, and steady state 15 atm. operation testing were performed successfully. The testing demonstrated stable and robust catalytic element component life for gas turbine conditions. The benefit of the catalytic hydrogen combustor technology includes capability of delivering near-zero NOx without costly post-combustion controls and without requirement for added sulfur control. In addition, reduced acoustics increase gas turbine component life. These advantages advances Department of Energy (DOE’s) objectives for achievement of low single digit NOx emissions, improvement in efficiency vs. postcombustion controls, fuel flexibility, a significant net reduction in Integrated Gasification Combined Cycle (IGCC) system net capital and operating costs, and a route to commercialization across the power generation field from micro turbines to industrial and utility turbines.« less

  2. The Interaction of Ethanol Ingestion and Social Interaction with an Intoxicated Peer on the Odor-Mediated Response to the Drug in Adolescent Rats.

    PubMed

    Eade, Amber M; Youngentob, Lisa M; Youngentob, Steven L

    2016-04-01

    Using a social transmission of food preference paradigm in rats, we previously demonstrated that ethanol (EtOH) exposure during adolescence, as either an observer (interaction with an intoxicated conspecific) or demonstrator (intragastric infusion with EtOH), altered the reflexive odor-mediated responses to the drug. The 2 modes of exposure were equivalent in the magnitude of their effects. Human adolescents, however, are likely to experience the drug in a social setting as both an EtOH observer and demonstrator. That is, both interacting with an intoxicated peer and experiencing EtOH's postingestive consequences in conjunction with hematogenic olfaction. Therefore, we tested whether combined adolescent exposure as both an observer and demonstrator differed from either form of individual experience. Beginning on postnatal day (P) 29, naïve rats received EtOH or water exposures in a social interaction paradigm as either an observer, a demonstrator, or combined experience (where each animal in the interaction was, itself, an observer and demonstrator). Exposures occurred 4 times, once every 48 hours. On P37, the reflexive behavioral response to EtOH odor was tested, using whole-body plethysmography. The odor-mediated responses of adolescent EtOH observers, demonstrators, and combined exposure animals all significantly differed from controls. Compared to controls, however, the magnitude of the behavioral effect was greatest in the combined exposure animals. Moreover, combined exposure as both an EtOH observer and demonstrator significantly differed from either form of individual EtOH experience. EtOH's component chemosensory qualities are known to be central contributors to its acceptance and increases in the acceptability of EtOH's odor, resulting from a social transmission experience, are predictive of enhanced EtOH avidity in adolescence. Our findings demonstrate that combined exposure as an observer and demonstrator, within a socially relevant framework, may represent a higher risk scenario for increased EtOH avidity in adolescence (and by extension adult persistence) as compared to the individual effects of direct ingestion or social experience with the drug. Copyright © 2016 by the Research Society on Alcoholism.

  3. Six minute walking test and carbon monoxide diffusing capacity for non-small cell lung cancer: easy performed tests in every day practice.

    PubMed

    Zarogoulidis, Paul; Kerenidi, Theodora; Huang, Haidong; Kontakiotis, Theodoros; Tremma, Ourania; Porpodis, Konstantinos; Kalianos, Anastasios; Rapti, Ageliki; Foroulis, Christoforos; Zissimopoulos, Athanasios; Courcoutsakis, Nikolaos; Zarogoulidis, Konstantinos

    2012-12-01

    Several studies have demonstrated that reduced lung function is a significant risk factor for lung cancer and increased surgical risk in patients with operable stages of lung cancer. The aim of the study was to perform pulmonary function tests and investigate which is a favorable respiratory function test for overall survival between lung cancer stages. Lung function tests were performed to lung cancer patients with non-small cell lung cancer of stage I, II, III and IV (241 patients in total). They had the last follow-up consecutively between December 2006 and July 2008. The staging was decided according to the sixth edition of TNM classification of NSCLC. The Forced Expiratory Volume in 1sec (FEV1), Forced Vital Capacity (FVC) and Carbon Monoxide Diffusing Capacity (DLCO) were measured according to American Thoracic Society/European Respiratory Society guidelines. The 6 Minute Walking Test (6MWT) was measured according to the American Thoracic Society. There was a significant association of the DLCO upon diagnosis and overall survival for stage II (P<0.007) and IV (P<0.003). Furthermore, there was a significant association between 6MWT and overall survival for stage III (P<0.001) and stage IV (P<0.010). The significance for each lung function test is different among the stages of NSCLC. DLCO and 6MWT upon admission are the most valuable prognostic factors for overall survival of NSCLC.

  4. Retrospective evaluation of exposure index (EI) values from plain radiographs reveals important considerations for quality improvement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mothiram, Ursula; Brennan, Patrick C; Robinson, John

    2013-12-15

    Following X-ray exposure, radiographers receive immediate feedback on detector exposure in the form of the exposure index (EI). To identify whether radiographers are meeting manufacturer-recommended EI (MREI) ranges for routine chest, abdomen and pelvis X-ray examinations under a variety of conditions and to examine factors affecting the EI. Data on 5000 adult X-ray examinations including the following variables were collected: examination parameters, EI values, patient gender, date of birth, date and time of examination, grid usage and the presence of implant or prosthesis. Descriptive statistics were used to summarize each data set and the Mann–Whitney U test was used tomore » determine significant differences, with P < 0.05 indicating significance for all tests. Most examinations demonstrated EI values that were outside the MREI ranges, with significantly higher median EI values recorded for female patient radiographs than those for male patients for all manufacturers, indicating higher detector exposures for all units except for Philips digital radiography (DR), where increased EI values indicate lower exposure (P = 0.01). Median EI values for out of hours radiography were also significantly higher compared with normal working hours for all technologies (P ≤ 0.02). Significantly higher median EI values were demonstrated for Philips DR chest X-rays without as compared to those with the employment of a grid (P = 0.03), while significantly lower median EI values were recorded for Carestream Health computed radiography (CR) chest X-rays when an implant or prosthesis was present (P = 0.02). Non-adherence to MREIs has been demonstrated with EI value discrepancies being dependent on patient gender, time/day of exposure, grid usage and the presence of an implant or prosthesis. Retrospective evaluation of EI databases is a valuable tool to assess the need of quality improvement in routine DR.« less

  5. Evaluation of molecular chaperons Hsp72 and neuropeptide Y as characteristic markers of adaptogenic activity of plant extracts.

    PubMed

    Asea, Alexzander; Kaur, Punit; Panossian, Alexander; Wikman, Karl Georg

    2013-11-15

    We have previously demonstrated that ADAPT-232, a fixed combination of adaptogenic substances derived from Eleutherococcus senticosus root extract, Schisandra chinensis berry extract, Rhodiola rosea root extract stimulated the expression and release of neuropeptide Y (NPY) and molecular chaperone Hsp72 from isolated human neurolgia cells. Both of these mediators of stress response are known to play an important role in regulation of neuroendocrine system and immune response. We further demonstrated that ADAPT-232 induced release of Hsp70 is mediated by NPY, suggesting an existence of NPY-mediated pathway of activation of Hsp72 release into the blood circulation system. The objective of this study was to determine whether this pathway is common for adaptogens and whether NPY and/or Hsp72 can be considered as necessary specific biomarkers for adaptogenic activity. The release of NPY and Hsp72 from neuroglia cells in response to treatment with various plant extracts (n=23) including selected validated adaptogens, partly validated adaptogens, claimed but negligibly validated adaptogens and some other plant extracts affecting neuroendocrine and immune systems but never considered as adaptogens was measured using high throughput ELISA techniques. We demonstrated that adaptogens, e.g. R. rosea, S. chinensis and E. senticosus stimulate both NPY and Hsp70 release from neuroblastoma cells, while tonics and stimulants have no significant effect on NPY in this in vitro test. In the groups of partly validated adaptogens the effect of Panax ginseng and Withania somnifera was not statistically significant both on NPY and Hsp70 release, while the activating effect of Bryonia alba and Rhaponticum cartamoides was significant only on Hsp70. In contrast, all tested non-adaptogens, such as antiinflammatoty plant extracts Matricaria recutita, Pelargonium sidoides, Hedera helix and Vitis vinifera significantly inhibit Hsp70 release and have no influence on NPY release from neuroblastoma cells. These experiments were further validated using primary human neurons and confirmed that adaptogens activate the release of both NPY and Hsp70, while tested non adaptogens were inactive in NPY assay and inhibit the release of Hsp70. Taken together, our data demonstrates for the first time that neuropeptide Y and heat shock protein Hsp70 can be used as molecular biomarkers for adaptogenic activity. Copyright © 2013 Elsevier GmbH. All rights reserved.

  6. Results of a nuclear power plant application of A New Technique for Human Error Analysis (ATHEANA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whitehead, D.W.; Forester, J.A.; Bley, D.C.

    1998-03-01

    A new method to analyze human errors has been demonstrated at a pressurized water reactor (PWR) nuclear power plant. This was the first application of the new method referred to as A Technique for Human Error Analysis (ATHEANA). The main goals of the demonstration were to test the ATHEANA process as described in the frame-of-reference manual and the implementation guideline, test a training package developed for the method, test the hypothesis that plant operators and trainers have significant insight into the error-forcing-contexts (EFCs) that can make unsafe actions (UAs) more likely, and to identify ways to improve the method andmore » its documentation. A set of criteria to evaluate the success of the ATHEANA method as used in the demonstration was identified. A human reliability analysis (HRA) team was formed that consisted of an expert in probabilistic risk assessment (PRA) with some background in HRA (not ATHEANA) and four personnel from the nuclear power plant. Personnel from the plant included two individuals from their PRA staff and two individuals from their training staff. Both individuals from training are currently licensed operators and one of them was a senior reactor operator on shift until a few months before the demonstration. The demonstration was conducted over a 5-month period and was observed by members of the Nuclear Regulatory Commission`s ATHEANA development team, who also served as consultants to the HRA team when necessary. Example results of the demonstration to date, including identified human failure events (HFEs), UAs, and EFCs are discussed. Also addressed is how simulator exercises are used in the ATHEANA demonstration project.« less

  7. Streamlined design and self reliant hardware for active control of precision space structures

    NASA Technical Reports Server (NTRS)

    Hyland, David C.; King, James A.; Phillips, Douglas J.

    1994-01-01

    Precision space structures may require active vibration control to satisfy critical performance requirements relating to line-of-sight pointing accuracy and the maintenance of precise, internal alignments. In order for vibration control concepts to become operational, it is necessary that their benefits be practically demonstrated in large scale ground-based experiments. A unique opportunity to carry out such demonstrations on a wide variety of experimental testbeds was provided by the NASA Control-Structure Integration (CSI) Guest Investigator (GI) Program. This report surveys the experimental results achieved by the Harris Corporation GI team on both Phases 1 and 2 of the program and provides a detailed description of Phase 2 activities. The Phase 1 results illustrated the effectiveness of active vibration control for space structures and demonstrated a systematic methodology for control design, implementation test. In Phase 2, this methodology was significantly streamlined to yield an on-site, single session design/test capability. Moreover, the Phase 2 research on adaptive neural control techniques made significant progress toward fully automated, self-reliant space structure control systems. As a further thrust toward productized, self-contained vibration control systems, the Harris Phase II activity concluded with experimental demonstration of new vibration isolation hardware suitable for a wide range of space-flight and ground-based commercial applications.The CSI GI Program Phase 1 activity was conducted under contract NASA1-18872, and the Phase 2 activity was conducted under NASA1-19372.

  8. Assessment of nurses' knowledge on evidence-based preventive practices for pressure ulcer risk reduction in patients with impaired mobility.

    PubMed

    Akese, M I; Adejumo, P O; Ilesanmi, R E; Obilor, H N

    2014-09-01

    The increase in the prevalence of pressure ulcer among patients with impaired physical mobility has currently been associated with nurses' inadequate knowledge of preventive interventions. To assess nurses' knowledge of pressure ulcer identification/staging, risk factors and evidence-based preventive practices. This descriptive study was carried out at the University Teaching Hospital Maiduguri (UMTH), Borno State, Nigeria. Total sampling technique was utilized in the recruitment of the study participants. An adapted 75-item-pressure ulcer questionnaire was used for data collection. The data were analyzed using SPSS version 16. The hypotheses on nurses' knowledge were tested at 0.05 level of significance using Chi square test. A total of 219 nurses participated in this study with response rate of 68.0%. The nurses' years of professional practice ranged from 1 to 35 years with a mean of 11.7 (± 7.8) years. Approximately, 73% of the nurses demonstrated a low level of knowledge of pressure ulcer identification/staging, 69.4% demonstrated an average level of knowledge of risk factors and 79.9% demonstrated high level of knowledge of preventive practices. The relationship between nurses' knowledge of risk factors and knowledge of preventive practices (p = 0.37) was not significant. Nurses demonstrated a knowledge deficit in core areas on pressure ulcer identification/staging, risk factors' assessment and evidence-based preventive practices. In order to address this dearth, there is a need to institute an educational-based practice-guideline on pressure ulcer prevention for nurses.

  9. Positive Impact of Nutritional Interventions on Serum Symmetric Dimethylarginine and Creatinine Concentrations in Client-Owned Geriatric Cats

    PubMed Central

    Hall, Jean A.; MacLeay, Jennifer; Yerramilli, Maha; Obare, Edward; Yerramilli, Murthy; Schiefelbein, Heidi; Paetau-Robinson, Inke; Jewell, Dennis E.

    2016-01-01

    A prospective study was conducted in client-owned geriatric cats to evaluate the short- term effects of a test food on serum symmetric dimethylarginine (SDMA) and creatinine (Cr) concentrations. Test food contained functional lipids (fish oil), antioxidants (vitamins C and E), L-carnitine, botanicals (vegetables), highly bioavailable protein, and amino acid supplements. Cats (n = 80) were fed either test food or owner’s-choice foods (non-nutritionally controlled cohort). Cats were included based on age (≥ 9 years), indoor only, neutered, and free of chronic disease. At baseline, all cats had serum Cr concentrations within the reference interval. Renal function biomarkers and urinalysis results at baseline and after consuming test food or owner’s-choice foods for 3 and 6 months were evaluated. Cats consuming test food showed significant decreases in serum Cr and BUN concentrations across time. Overall, cats consuming owner’s-choice foods showed significant increases in serum SDMA concentrations at 3 and 6 months compared with baseline (P ≤ 0.05), whereas in cats consuming test food serum SDMA concentrations did not change. At baseline or during the 6-month feeding trial, 23 (28.8%) cats had increased serum SDMA, but normal serum Cr consistent with IRIS Stage 1 chronic kidney disease. This included 6 cats fed test food and 17 cats fed owner’s-choice foods. In the 6 cats fed test food, serum SDMA decreased in 3 cats and remained stable in 1 cat, whereas in the 17 cats fed owner’s-choice foods, serum SDMA increased in 13 cats and decreased or remained stable in 4 cats. The increase in serum SDMA concentration was significant (P = 0.02) only for cats fed owner’s-choice foods. These results suggest that nonazotemic cats with elevated serum SDMA (early renal insufficiency) when fed a food designed to promote healthy aging are more likely to demonstrate stable renal function compared with cats fed owner’s-choice foods. Cats fed owner’s-choice foods were more likely to demonstrate progressive renal insufficiency. PMID:27078852

  10. Postural control and risk of falling in bipodalic and monopodalic stabilometric tests of healthy subjects before, after visuo-proprioceptive vestibulo-postural rehabilitation and at 3 months thereafter: role of the proprioceptive system.

    PubMed

    De Carli, P; Patrizi, M; Pepe, L; Cavaniglia, G; Riva, D; D'Ottavi, L R

    2010-08-01

    Nine healthy volunteers (6 males, 3 females), mean age 34.5 years (SD = 11.52), underwent a vestibulo-postural rehabilitation cycle with a visuo-proprioceptive-type stimulus. All subjects in the study group were evaluated by means of stabilometric bipodalic and monopodalic tests both before and immediately after treatment, and again 3 month thereafter. The Delos Postural Proprioceptive System®, DPPS (Delos, srl, Turin, Italy), was used in performing these stabilometric tests and in the rehabilitation exercises. The first aim of the study was to evaluate to what extent the functional level of the proprioceptive system was reliable, in healthy subjects, in the control of postural stability; the second was to demonstrate the possibility to increase this level by means of a novel visuo-proprioceptive feedback training; the last was to establish whether or not the increase achieved was permanent. The bipodalic test did not reveal any deficit in posture either before or after rehabilitation. The monopodalic test prior to treatment, with eyes closed, revealed, in 2/3 of the study group, evidence of the risk of falling, expressed as the precautional strategy (8.57 ± 6.18% SD). An increase in the proprioceptive activity, obtained in the subjects examined immediately after the visuo-proprioceptive vestibulo-postural rehabilitation, led, in the monopodalic test, with eyes closed, to a significant reduction in the risk of falling (with the precautional strategy equal to 1.09 ± 2.63% SD, p = 0.004). The monopodalic test, with eyes closed, 3 months after rehabilitation, demonstrated results not unlike those pre-treament with values, therefore, not more significant than those emerging from the pre-treatment test. Thus, from the above-mentioned data, it can be observed that, also in healthy subjects, there may be different levels of postural proprioceptive control related to a high risk of falling. These levels can be maintained constant for a certain period of time, until a significant reduction in the risk of falling is achieved, only if continuously stimulated by appropriate sensorial information.

  11. Ethical Issues of Predictive Genetic Testing for Diabetes

    PubMed Central

    Haga, Susanne B.

    2009-01-01

    With the rising number of individuals affected with diabetes and the significant health care costs of treatment, the emphasis on prevention is key to controlling the health burden of this disease. Several genetic and genomic studies have identified genetic variants associated with increased risk to diabetes. As a result, commercial testing is available to predict an individual's genetic risk. Although the clinical benefits of testing have not yet been demonstrated, it is worth considering some of the ethical implications of testing for this common chronic disease. In this article, I discuss several issues that should be considered during the translation of predictive testing for diabetes, including familial implications, improvement of risk communication, implications for behavioral change and health outcomes, the Genetic Information Nondiscrimination Act, direct-to-consumer testing, and appropriate age of testing. PMID:20144329

  12. Intelligent Mobile Technologies

    NASA Technical Reports Server (NTRS)

    Alena, Rick; Gilbaugh, Bruce; Glass, Brian; Swanson, Keith (Technical Monitor)

    2000-01-01

    Testing involves commercial radio equipment approved for export and use in Canada. Testing was conducted in the Canadian High Arctic, where hilly terrain provided the worst-case testing. SFU and Canadian governmental agencies made significant technical contributions. The only technical data related to radio testing was exchanged with SFU. Test protocols are standard radio tests performed by communication technicians worldwide. The Joint Fields Operations objectives included the following: (1) to provide Internet communications services for field science work and mobile exploration systems; (2) to evaluate the range and throughput of three different medium-range radio link technologies for providing coverage of the crater area; and (3) to demonstrate collaborative software such as NetMeeting with multi-point video for exchange of scientific information between remote node and base-base camp and science centers as part of communications testing.

  13. NaK pool-boiler bench-scale receiver durability test: Test results and materials analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andraka, C.E.; Goods, S.H.; Bradshaw, R.W.

    1994-06-01

    Pool-boiler reflux receivers have been considered as an alternative to heat pipes for the input of concentrated solar energy to Stirling-cycle engines in dish-Stirling electric generation systems. Pool boilers offer simplicity in design and fabrication. The operation of a full-scale pool-boiler receiver has been demonstrated for short periods of time. However, to generate cost-effective electricity, the receiver must operate Without significant maintenance for the entire system life, as much as 20 to 30 years. Long-term liquid-metal boiling stability and materials compatibility with refluxing NaK-78 is not known and must be determined for the pool boiler receiver. No boiling system hasmore » been demonstrated for a significant duration with the current porous boiling enhancement surface and materials. Therefore, it is necessary to simulate the full-scale pool boiler design as much as possible, including flux levels, materials, and operating cycles. On-sun testing is impractical because of the limited test time available. A test vessel was constructed with a porous boiling enhancement surface. The boiling surface consisted of a brazed stainless steel powder with about 50% porosity. The vessel was heated with a quartz lamp array providing about go W/CM2 peak incident thermal flux. The vessel was charged with NaK-78. This allows the elimination of costly electric preheating, both on this test and on fullscale receivers. The vessel was fabricated from Haynes 230 alloy. The vessel operated at 750{degrees}C around the clock, with a 1/2-hour shutdown cycle to ambient every 8 hours. The test completed 7500 hours of lamp-on operation time, and over 1000 startups from ambient. The test was terminated when a small leak in an Inconel 600 thermowell was detected. The test design and data are presented here. Metallurgical analysis of virgin and tested materials has begun, and initial results are also presented.« less

  14. Inverse finite-size scaling for high-dimensional significance analysis

    NASA Astrophysics Data System (ADS)

    Xu, Yingying; Puranen, Santeri; Corander, Jukka; Kabashima, Yoshiyuki

    2018-06-01

    We propose an efficient procedure for significance determination in high-dimensional dependence learning based on surrogate data testing, termed inverse finite-size scaling (IFSS). The IFSS method is based on our discovery of a universal scaling property of random matrices which enables inference about signal behavior from much smaller scale surrogate data than the dimensionality of the original data. As a motivating example, we demonstrate the procedure for ultra-high-dimensional Potts models with order of 1010 parameters. IFSS reduces the computational effort of the data-testing procedure by several orders of magnitude, making it very efficient for practical purposes. This approach thus holds considerable potential for generalization to other types of complex models.

  15. Genotyping of the Alzheimer's Disease Genome-Wide Association Study Index Single Nucleotide Polymorphisms in the Brains for Dementia Research Cohort.

    PubMed

    Brookes, Keeley J; McConnell, George; Williams, Kirsty; Chaudhury, Sultan; Madhan, Gaganjit; Patel, Tulsi; Turley, Christopher; Guetta-Baranes, Tamar; Bras, Jose; Guerreiro, Rita; Hardy, John; Francis, Paul T; Morgan, Kevin

    2018-06-08

    The Brains for Dementia Research project is a recently established longitudinal cohort which aims to provide brain tissue for research purposes from neuropathologically defined samples. Here we present the findings from our analysis on the 19 established GWAS index SNPs for Alzheimer's disease, in order to demonstrate if the BDR sample also displays association to these variants. A highly significant association of the APOEɛ4 allele was identified (p = 3.99×10-12). Association tests for the 19 GWAS SNPs found that although no SNPs survive multiple testing, nominal significant findings were detected and concordance with the Lambert et al. GWAS meta-analysis was observed.

  16. Vestibular effects of cochlear implantation.

    PubMed

    Buchman, Craig A; Joy, Jennifer; Hodges, Annelle; Telischi, Fred F; Balkany, Thomas J

    2004-10-01

    Cochlear implantation (CI) carries with it the potential risk for vestibular system insult or stimulation with resultant dysfunction. As candidate profiles continue to evolve and with the recent development of bilateral CI, understanding the significance of this risk takes on an increasing importance. Between 1997 to 2001, a prospective observational study was carried out in a tertiary care medical center to assess the effects of unilateral CI on the vestibular system. Assessment was performed using the dizziness handicap inventory (DHI), vestibulo-ocular reflex (VOR) testing using both alternate bithermal caloric irrigations (ENG) and rotational chair-generated sinusoidal harmonic accelerations (SHA), and computerized dynamic platform posturography (CDP) at preoperative, 1-month, 4-month, 1-year and 2-year postimplantation visits. CI was carried out without respect to the preoperative vestibular function test results. Specifically, 86 patients were entered into the study after informed consent. For the group as a whole, pair wise comparisons revealed few significant differences between preoperative and postoperative values for VOR testing (ENG and SHA) at any of the follow-up intervals. Likewise, DHI testing was also unchanged except for significant reductions (improvements) in the emotional subcategory scores at both the 4-month and 1-year intervals. CDP results demonstrated substantial improvements in postural sway in the vestibular conditions (5 and 6) as well as composite scores with the device "off" and "on" at the 1-month, 4-month, 1-year, and 2-year intervals. Device activation appeared to improve postural stability in some conditions. Excluding those patients with preoperative areflexic or hyporeflexic responses in the implanted ear (total [warm + cool] caloric response or=21 deg/s maximum slow phase velocity) in total caloric response were observed for 8 (29%) patients at the 4-month interval. These persisted throughout the study period. These changes were accompanied by significant low frequency phase changes on SHA testing confirming a VOR insult. Of interest, no significant changes were detected in the DHI or CDP, and there were no effects of age, sex, device manufacturer, or etiology of hearing loss (HL) for these patients. Unilateral CI rarely results in significant adverse effects on the vestibular system as measured by the DHI, ENG, SHA, and CDP. On the contrary, patients that underwent CI experienced significant improvements in the objective measures of postural stability as measured by CDP. Device activation in music appeared to have an additional positive effect on postural stability during CDP testing. Although VOR testing demonstrated some decreases in response, patients did not suffer from disabling vestibular effects following CI. The mechanism underlying these findings remains speculative. These findings should be considered in counseling patients about CI.

  17. Glutamate decarboxylase genes and alcoholism in Han Taiwanese men.

    PubMed

    Loh, El-Wui; Lane, Hsien-Yuan; Chen, Chien-Hsiun; Chang, Pi-Shan; Ku, Li-Wen; Wang, Kathy H T; Cheng, Andrew T A

    2006-11-01

    Glutamate decarboxylase (GAD), the rate-limiting enzyme in the synthesis of gamma-aminobutyric acid (GABA), may be involved in the development of alcoholism. This study examined the possible roles of the genes that code for 2 forms of GAD (GAD1 and GAD2) in the development of alcoholism. An association study was conducted among 140 male alcoholic subjects meeting the DSM-III-R criteria for alcohol dependence and 146 controls recruited from the Han Taiwanese in community and clinical settings. Psychiatric assessment of drinking conditions was conducted using a Chinese version of the Schedules for Clinical Assessment in Neuropsychiatry. The SHEsis and Haploview programs were used in statistical analyses. Nine single-nucleotide polymorphisms (SNPs) at the GAD1 gene were valid for further statistics. Between alcoholic subjects and controls, significant differences were found in genotype distributions of SNP1 (p=0.000), SNP2 (p=0.015), SNP4 (p=0.015), SNP5 (p=0.031), SNP6 (p=0.012), and SNP8 (p=0.004) and in allele distributions of SNP1 (p=0.001), SNP2 (p=0.009), and SNP8 (p=0.009). Permutation tests of SNP1, SNP2, and SNP8 demonstrated significant differences in allele frequencies but not in 2 major haplotype blocks. Three valid SNPs at the GAD2 gene demonstrated no associations with alcoholism. Further permutation tests in the only 1 haplotype block or individual SNPs demonstrated no significant differences. This is the first report indicating a possible significant role of the GAD1 gene in the development of alcohol dependence and/or the course of alcohol withdrawal and outcome of alcoholism.

  18. Validity and Reliability of the Brazilian Version of the Rapid Estimate of Adult Literacy in Dentistry--BREALD-30.

    PubMed

    Junkes, Monica C; Fraiz, Fabian C; Sardenberg, Fernanda; Lee, Jessica Y; Paiva, Saul M; Ferreira, Fernanda M

    2015-01-01

    The aim of the present study was to translate, perform the cross-cultural adaptation of the Rapid Estimate of Adult Literacy in Dentistry to Brazilian-Portuguese language and test the reliability and validity of this version. After translation and cross-cultural adaptation, interviews were conducted with 258 parents/caregivers of children in treatment at the pediatric dentistry clinics and health units in Curitiba, Brazil. To test the instrument's validity, the scores of Brazilian Rapid Estimate of Adult Literacy in Dentistry (BREALD-30) were compared based on occupation, monthly household income, educational attainment, general literacy, use of dental services and three dental outcomes. The BREALD-30 demonstrated good internal reliability. Cronbach's alpha ranged from 0.88 to 0.89 when words were deleted individually. The analysis of test-retest reliability revealed excellent reproducibility (intraclass correlation coefficient = 0.983 and Kappa coefficient ranging from moderate to nearly perfect). In the bivariate analysis, BREALD-30 scores were significantly correlated with the level of general literacy (rs = 0.593) and income (rs = 0.327) and significantly associated with occupation, educational attainment, use of dental services, self-rated oral health and the respondent's perception regarding his/her child's oral health. However, only the association between the BREALD-30 score and the respondent's perception regarding his/her child's oral health remained significant in the multivariate analysis. The BREALD-30 demonstrated satisfactory psychometric properties and is therefore applicable to adults in Brazil.

  19. Validity and Reliability of the Brazilian Version of the Rapid Estimate of Adult Literacy in Dentistry – BREALD-30

    PubMed Central

    Junkes, Monica C.; Fraiz, Fabian C.; Sardenberg, Fernanda; Lee, Jessica Y.; Paiva, Saul M.; Ferreira, Fernanda M.

    2015-01-01

    Objective The aim of the present study was to translate, perform the cross-cultural adaptation of the Rapid Estimate of Adult Literacy in Dentistry to Brazilian-Portuguese language and test the reliability and validity of this version. Methods After translation and cross-cultural adaptation, interviews were conducted with 258 parents/caregivers of children in treatment at the pediatric dentistry clinics and health units in Curitiba, Brazil. To test the instrument's validity, the scores of Brazilian Rapid Estimate of Adult Literacy in Dentistry (BREALD-30) were compared based on occupation, monthly household income, educational attainment, general literacy, use of dental services and three dental outcomes. Results The BREALD-30 demonstrated good internal reliability. Cronbach’s alpha ranged from 0.88 to 0.89 when words were deleted individually. The analysis of test-retest reliability revealed excellent reproducibility (intraclass correlation coefficient = 0.983 and Kappa coefficient ranging from moderate to nearly perfect). In the bivariate analysis, BREALD-30 scores were significantly correlated with the level of general literacy (rs = 0.593) and income (rs = 0.327) and significantly associated with occupation, educational attainment, use of dental services, self-rated oral health and the respondent’s perception regarding his/her child's oral health. However, only the association between the BREALD-30 score and the respondent’s perception regarding his/her child's oral health remained significant in the multivariate analysis. Conclusion The BREALD-30 demonstrated satisfactory psychometric properties and is therefore applicable to adults in Brazil. PMID:26158724

  20. Unavoidable Pressure Ulcers: Development and Testing of the Indiana University Health Pressure Ulcer Prevention Inventory.

    PubMed

    Pittman, Joyce; Beeson, Terrie; Terry, Colin; Dillon, Jill; Hampton, Charity; Kerley, Denise; Mosier, Judith; Gumiela, Ellen; Tucker, Jessica

    2016-01-01

    Despite prevention strategies, hospital-acquired pressure ulcers (HAPUs) continue to occur in the acute care setting. The purpose of this study was to develop an operational definition of and an instrument for identifying avoidable/unavoidable HAPUs in the acute care setting. The Indiana University Health Pressure Ulcer Prevention Inventory (PUPI) was developed and psychometric testing was performed. A retrospective pilot study of 31 adult hospitalized patients with an HAPU was conducted using the PUPI. Overall content validity index of 0.99 and individual item content validity index scores (0.9-1.0) demonstrated excellent content validity. Acceptable PUPI criterion validity was demonstrated with no statistically significant differences between wound specialists' and other panel experts' scoring. Construct validity findings were acceptable with no statistically significant differences among avoidable or unavoidable HAPU patients and their Braden Scale total scores. Interrater reliability was acceptable with perfect agreement on the total PUPI score between raters (κ = 1.0; P = .025). Raters were in total agreement 93% (242/260) of the time on all 12 individual PUPI items. No risk factors were found to be significantly associated with unavoidable HAPUs. An operational definition of and an instrument for identifying avoidable/unavoidable HAPUs in the acute care setting were developed and tested. The instrument provides an objective and structured method for identifying avoidable/unavoidable HAPUs. The PUPI provides an additional method that could be used in root-cause analyses and when reporting adverse pressure ulcer events.

  1. Calf Endurance and Achilles Tendon Structure in Classical Ballet Dancers.

    PubMed

    Zellers, Jennifer A; van Ostrand, Katrina; Silbernagel, Karin Grävare

    2017-06-15

    Optimal lower leg function is critical for ballet dancers to meet their occupational requirements. Achilles tendon injury is particularly detrimental to ballet dancers. While standardized measures have been validated and incorporated into clinical practice for use in people with Achilles tendon injury, normative ranges specific to the dancer population have not been described. The purpose of this pilot study was to observe the performance of pre-professional ballet students and professional ballet dancers on a well-established test battery for lower leg functional performance as well as ultra-sonographic evaluation of the structure of their Achilles tendons. The dancers in this study had significantly shorter Achilles tendons than non-dancers (p = 0.016). Dancers demonstrated significantly higher maximum heel-rise height on the heel-rise test for calf endurance (p < 0.001) but performed significantly less work than non-dancers (p = 0.014). The results of this study support the use of the heel-rise test as a tool for screening and to guide rehabilitation.

  2. WF/PC internal molecular contamination during system thermal-vacuum test

    NASA Technical Reports Server (NTRS)

    Taylor, Daniel M.; Barengoltz, J.; Jenkins, T.; Leschly, K.; Triolo, J.

    1988-01-01

    During the recent system thermal vacuum test of the Wide-Field/Planetary Camera (WF/PC), instrumentation was added to the WF/PC to characterize the internal molecular contamination and verify the instrument throughput down to 1470 angstroms. Analysis of data elements revealed two contaminants affecting the far-ultraviolet (FUV) performance of the WF/PC. The one contaminant (heavy volatile) is correlated with the electronic and housing temperature, and the contamination is significantly reduced when the electronics are operated below plus 8 degrees to plus 10 degrees C. The other contaminant (light volatile) is controlled by the heat pipe temperature, and the contamination is significantly reduced when the Thermal Electric Cooler (TEC) hot-junction temperature is below minus 40 degrees to minus 50 degrees C. The utility of contamination sensors located behind instruments during system tests was demonstrated.

  3. Using personal qualities assessment to measure the moral orientation and personal qualities of medical students in a non-Western culture.

    PubMed

    Tsou, Kuo-Inn; Lin, Chaou-Shune; Cho, Shu-Ling; Powis, David; Bore, Miles; Munro, Don; Sze, Daniel Man-Yuen; Wu, Hsi-Chin; Hsieh, Ming-Shium; Lin, Chyi-Her

    2013-06-01

    How to select candidates with appropriate personal qualities for medical school is an important issue. This study examined the psychometric properties and group differences of the Personal Qualities Assessment (PQA) to test the feasibility of using it as a tool to assess the medical school applicants in a non-Western culture. Seven hundred forty-six medical students in Taiwan completed two psychometric measures: Mojac to assess moral orientation and NACE to assess four aspects of interpersonal relationships. Thirty-one students completed the tests twice to establish test-retest reliability. A subsample of 127 students also completed a measure of the "Big Five" personality traits to examine the construct validity of these scales. Both Mojac and NACE had acceptable internal consistency and test-retest reliability. Conceptually, coherent and significant relationships were observed between test components and between the NACE and Big Five. NACE but not Mojac varied significantly between different sociodemographic groups. Both tests demonstrated acceptable psychometric properties. However, the predictive validity of PQA requires future studies.

  4. Failure analysis of pinch-torsion tests as a thermal runaway risk evaluation method of Li-ion cells

    NASA Astrophysics Data System (ADS)

    Xia, Yuzhi; Li, Tianlei; Ren, Fei; Gao, Yanfei; Wang, Hsin

    2014-11-01

    Recently a pinch-torsion test is developed for safety testing of Li-ion batteries. It has been demonstrated that this test can generate small internal short-circuit spots in the separator in a controllable and repeatable manner. In the current research, the failure mechanism is examined by numerical simulations and comparisons to experimental observations. Finite element models are developed to evaluate the deformation of the separators under both pure pinch and pinch-torsion loading conditions. It is discovered that the addition of the torsion component significantly increased the maximum first principal strain, which is believed to induce the internal short circuit. In addition, the applied load in the pinch-torsion test is significantly less than in the pure pinch test, thus dramatically improving the applicability of this method to ultra-thick batteries which otherwise require heavy load in excess of machine capability. It is further found that the separator failure is achieved in the early stage of torsion (within a few degree of rotation). Effect of coefficient of friction on the maximum first principal strain is also examined.

  5. Combined-load stress-strain relationship for advanced fiber composites

    NASA Technical Reports Server (NTRS)

    Chamis, C. C.; Sullivan, T. L.

    1975-01-01

    It was demonstrated experimentally that only one test specimen is required to determine the combined-load stress-strain relationships of a given fiber composite system. These relationships were determined using a thin angle-plied laminate tube and subjecting it to a number of combined-loading conditions. The measured data obtained are compared with theoretical predictions. Some important considerations associated with such a test are identified, and the significance of combined-load stress-strain relationships in certain practical designs are discussed.

  6. High Pressure Regenerative Turbine Engine: 21st Century Propulsion

    NASA Technical Reports Server (NTRS)

    Lear, W. E.; Laganelli, A. L.; Senick, Paul (Technical Monitor)

    2001-01-01

    A novel semi-closed cycle gas turbine engine was demonstrated and was found to meet the program goals. The proof-of-principle test of the High Pressure Regenerative Turbine Engine produced data that agreed well with models, enabling more confidence in designing future prototypes based on this concept. Emission levels were significantly reduced as predicted as a natural attribute of this power cycle. Engine testing over a portion of the operating range allowed verification of predicted power increases compared to the baseline.

  7. Rotational and translational stability of different methods for direct acromioclavicular ligament repair in anatomic acromioclavicular joint reconstruction.

    PubMed

    Beitzel, Knut; Obopilwe, Elifho; Apostolakos, John; Cote, Mark P; Russell, Ryan P; Charette, Ryan; Singh, Hardeep; Arciero, Robert A; Imhoff, Andreas B; Mazzocca, Augustus D

    2014-09-01

    Many reconstructions of acromioclavicular (AC) joint dislocations have focused on the coracoclavicular (CC) ligaments and neglected the functional contribution of the AC ligaments and the deltotrapezial fascia. To compare the modifications of previously published methods for direct AC reconstruction in addition to a CC reconstruction. The hypothesis was that there would be significant differences within the variations of surgical reconstructions. Controlled laboratory study. A total of 24 cadaveric shoulders were tested with a servohydraulic testing system. Two digitizing cameras evaluated the 3-dimensional movement. All reconstructions were based on a CC reconstruction using 2 clavicle tunnels and a tendon graft. The following techniques were used to reconstruct the AC ligaments: a graft was shuttled underneath the AC joint back from anterior and again sutured to the acromial side of the joint (group 1), a graft was fixed intramedullary in the acromion and distal clavicle (group 2), a graft was passed over the acromion and into an acromial tunnel (group 3), and a FiberTape was fixed in a cruciate configuration (group 4). Anterior, posterior, and superior translation, as well as anterior and posterior rotation, were tested. Group 1 showed significantly less posterior translation compared with the 3 other groups (P < .05) but did not show significant differences compared with the native joint. Groups 3 and 4 demonstrated significantly more posterior translation than the native joint. Group 1 showed significantly less anterior translation compared with groups 2 and 3. Group 3 demonstrated significantly more anterior translation than the native joint. Group 1 demonstrated significantly less superior translation compared with the other groups and with the native joint. The AC joint of group 1 was pulled apart less compared with all other reconstructions. Only group 1 reproduced the native joint for the anterior rotation at the posterior marker. Group 4 showed significantly increased distances for all 3 measure points when the clavicle was rotated posteriorly. Reconstruction of the AC ligament by direct wrapping and suturing of the remaining graft around the AC joint (group 1) was the most stable method and was the only one to show anterior rotation comparable with the native joint. In contrast, the transacromial technique (group 3) showed the most translation and rotation. An anatomic repair should address both the CC ligaments and the AC ligaments to control the optimal physiologic function (translation and rotation). © 2014 The Author(s).

  8. T55 power turbine rotor multiplane-multispeed balancing study

    NASA Technical Reports Server (NTRS)

    Martin, M. R.

    1982-01-01

    A rotordynamic analysis of the T55-L-11C engine was used to evaluate the balancing needs of the power turbine and to optimize the balancing procedure. As a result, recommendations were made for implementation of a multiplane-multispeed balancing plan. Precision collars for the attachment of trial weights to a slender rotor were designed enabling demonstration balancing on production hardware. The quality of the balance was then evaluated by installing a high speed balanced power turbine in an engine and running in a test cell at the Corpus Christi Army depot. The engine used had been tested prior to the turbine changeout and showed acceptable overall vibration levels for the engine were significantly reduced, demonstrating the ability of multiplane-multispeed balancing to control engine vibration.

  9. AGT100 turbomachinery. [for automobiles

    NASA Technical Reports Server (NTRS)

    Tipton, D. L.; Mckain, T. F.

    1982-01-01

    High-performance turbomachinery components have been designed and tested for the AGT100 automotive engine. The required wide range of operation coupled with the small component size, compact packaging, and low cost of production provide significant aerodynamic challenges. Aerodynamic design and development testing of the centrifugal compressor and two radial turbines are described. The compressor achieved design flow, pressure ratio, and surge margin on the initial build. Variable inlet guide vanes have proven effective in modulating flow capacity and in improving part-speed efficiency. With optimum use of the variable inlet guide vanes, the initial efficiency goals have been demonstrated in the critical idle-to-70% gasifier speed range. The gasifier turbine exceeded initial performance goals and demonstrated good performance over a wide range. The radial power turbine achieved 'developed' efficiency goals on the first build.

  10. Associations of Sexual Victimization, Depression, and Sexual Assertiveness with Unprotected Sex: A Test of the Multifaceted Model of HIV Risk Across Gender

    PubMed Central

    Morokoff, Patricia J.; Redding, Colleen A.; Harlow, Lisa L.; Cho, Sookhyun; Rossi, Joseph S.; Meier, Kathryn S.; Mayer, Kenneth H.; Koblin, Beryl; Brown-Peterside, Pamela

    2014-01-01

    This study examined whether the Multifaceted Model of HIV Risk (MMOHR) would predict unprotected sex based on predictors including gender, childhood sexual abuse (CSA), sexual victimization (SV), depression, and sexual assertiveness for condom use. A community-based sample of 473 heterosexually active men and women, aged 18–46 years completed survey measures of model variables. Gender predicted several variables significantly. A separate model for women demonstrated excellent fit, while the model for men demonstrated reasonable fit. Multiple sample model testing supported the use of MMOHR in both men and women, while simultaneously highlighting areas of gender difference. Prevention interventions should focus on sexual assertiveness, especially for CSA and SV survivors, as well as targeting depression, especially among men. PMID:25018617

  11. Incarcerated Violent Offenders' Ability to Avoid Revealing Their Potential for Violence on the Rorschach and the MMPI-2.

    PubMed

    Nørbech, Peder Chr Bryhn; Fodstad, Lars; Kuisma, Irene; Lunde, Ketil Berge; Hartmann, Ellen

    2016-01-01

    Recently, Hartmann and Hartmann (2014) found that psychiatric outpatients, both with and without access to Internet-based information about the Rorschach Inkblot Method (RIM; Weiner, 2003 ) and the MMPI-2 (Butcher, Dahlstrom, Graham, Tellegen, & Kaemmer, 1989 ), were unable to imitate healthy test performance on these tests. We replicated the study by administering the RIM and the MMPI-2 to 63 incarcerated violent offenders using similar testing conditions. As in the previous study, comparisons were made not only among the 3 subgroups of incarcerated offenders, but also between these offender groups and the group of nonpatients examined in the previous study. On the RIM, Internet-coached and uncoached "faking good" offenders produced records with significantly higher F% and X-% and significantly lower M, m, SumC, X+%, P, AG, and COP than nonoffenders under standard instructions (effect sizes between d = 0.24 and d = 2.39). For AgC, AgPot, AgPast, and TCI% there were no significant differences between the faking offenders and the nonoffenders under standard instructions. On the MMPI-2 clinical scales, there were no significant differences between the faking good groups and the nonoffenders under standard instructions, except on Hs, Pd, and Sc. Both faking groups were identifiable by their high L scale scores. Although both faking groups managed to avoid giving responses with aggressive and generally psychopathological content on the RIM, they were unable to produce test profiles demonstrating healthy test performance on any of the tests; nevertheless, Internet-based test information might weaken test validity.

  12. Forecasting volatility with neural regression: a contribution to model adequacy.

    PubMed

    Refenes, A N; Holt, W T

    2001-01-01

    Neural nets' usefulness for forecasting is limited by problems of overfitting and the lack of rigorous procedures for model identification, selection and adequacy testing. This paper describes a methodology for neural model misspecification testing. We introduce a generalization of the Durbin-Watson statistic for neural regression and discuss the general issues of misspecification testing using residual analysis. We derive a generalized influence matrix for neural estimators which enables us to evaluate the distribution of the statistic. We deploy Monte Carlo simulation to compare the power of the test for neural and linear regressors. While residual testing is not a sufficient condition for model adequacy, it is nevertheless a necessary condition to demonstrate that the model is a good approximation to the data generating process, particularly as neural-network estimation procedures are susceptible to partial convergence. The work is also an important step toward developing rigorous procedures for neural model identification, selection and adequacy testing which have started to appear in the literature. We demonstrate its applicability in the nontrivial problem of forecasting implied volatility innovations using high-frequency stock index options. Each step of the model building process is validated using statistical tests to verify variable significance and model adequacy with the results confirming the presence of nonlinear relationships in implied volatility innovations.

  13. Transference of bioactive compounds from support plants to the termites Constrictotermes cyphergaster (Isoptera).

    PubMed

    Policarpo, Iamara Silva; Vasconcellos, Alexandre; Chaves, Thiago Pereira; Raimundo, Joanda Paolla; Medeiros, Ana Cláudia D; Coutinho, Henrique D M; Alves, Rômulo Romeu Nóbrega

    2018-10-15

    This study aims to investigate the microbiological potential of the termite species Constrictotermes cyphergaster (Silvestri, 1901) and its support plants. We collected five C. cyphergaster nests from three different support plant species. Microbiological assays were performed on these extracts using the serial microdilution method in triplicate to measure the minimum inhibitory concentration (MIC) of each microorganism for the analysed extract. The ethanol extracts of the termite C. cyphergaster showed no significant activity against strains of Staphylococcus aureus and Escherichia coli, with an MIC >1000 μg mL-1. Only the extracts of the nests and termites with the nest had the same MICs. These results were in contrast to the extracts of Spondias tuberosa (Umbuzeiro), Poincianella pyramidalis (Catingueira), and Amburana cearensis (Cumaru), which demonstrated significant activity against S. aureus with MICs <1000 μg mL-1. The modulating activity of the extracts tested in the present study demonstrated potentiation of most antibiotics across the bacterial strains tested when combined with the extracts for both S. aureus and E. coli. These results indicate that the extracts tested in the present study may be composed of animal and vegetable origins with the potential to modify the activity of antibiotics and thus may aid in antimicrobial therapy. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Bupleurum falcatum prevents depression and anxiety-like behaviors in rats exposed to repeated restraint stress.

    PubMed

    Lee, Bombi; Yun, Hye-Yeon; Shim, Insop; Lee, Hyejung; Hahm, Dae-Hyun

    2012-03-01

    Previous studies have demonstrated that repeated restraint stress in rodents produces increases in depression and anxietylike behaviors and alters the expression of corticotrophinreleasing factor (CRF) in the hypothalamus. The current study focused on the impact of Bupleurum falcatum (BF) extract administration on repeated restraint stress-induced behavioral responses using the forced swimming test (FST) and elevated plus maze (EPM) test. Immunohistochemical examinations of tyrosine hydroxylase (TH) expression in rat brain were also conducted. Male rats received daily doses of 20, 50, or 100 mg/kg (i.p.) BF extract for 15 days, 30 min prior to restraint stress (4 h/day). Hypothalamicpituitary- adrenal axis activation in response to repeated restraint stress was confirmed base on serum corticosterone levels and CRF expression in the hypothalamus. Animals that were pre-treated with BF extract displayed significantly reduced immobility in the FST and increased open-arm exploration in the EPM test in comparison with controls. BF also blocked the increase in TH expression in the locus coeruleus of treated rats that experienced restraint stress. Together, these results demonstrate that BF extract administration prior to restraint stress significantly reduces depression and anxiety-like behaviors, possibly through central adrenergic mechanisms, and they suggest a role for BF extract in the treatment of depression and anxiety disorders.

  15. Retention of Implicit Sequence Learning in Persons who Stutter and Persons with Parkinson's Disease

    PubMed Central

    Smits-Bandstra, Sarah; Gracco, Vincent

    2014-01-01

    This study investigated the retention of implicit sequence learning in 14 persons with Parkinson's disease (PPD), 14 persons who stutter (PWS) and 14 control participants. Participants completed a nonsense syllable serial reaction time task in a 120-minute session. Participants named aloud four syllables in response to four visual stimuli. The syllables formed a repeating 8-item sequence not made known to participants. After one week, participants completed a 60-minute retention session that included an explicit learning questionnaire and a sequence generation task. PPD showed retention of general learning equivalent to controls but PWS's reaction times were significantly slower on early trials of the retention test relative to other groups. Controls showed implicit learning during the initial session that was retained on the retention test. In contrast, PPD and PWS did not demonstrate significant implicit learning until the retention test suggesting intact, but delayed, learning and retention of implicit sequencing skills. All groups demonstrated similar limited explicit sequence knowledge. Performance differences between PWS and PPD relative to controls during the initial session and on early retention trials indicated possible dysfunction of the cortico-striato-thalamo-cortical loop. The etiological implications for stuttering, and clinical implications for both populations, of this dysfunction are discussed. PMID:23844763

  16. Similarity Rules for Scaling Solar Sail Systems

    NASA Technical Reports Server (NTRS)

    Canfield, Stephen L.; Peddieson, John; Garbe, Gregory

    2010-01-01

    Future science missions will require solar sails on the order of 200 square meters (or larger). However, ground demonstrations and flight demonstrations must be conducted at significantly smaller sizes, due to limitations of ground-based facilities and cost and availability of flight opportunities. For this reason, the ability to understand the process of scalability, as it applies to solar sail system models and test data, is crucial to the advancement of this technology. This paper will approach the problem of scaling in solar sail models by developing a set of scaling laws or similarity criteria that will provide constraints in the sail design process. These scaling laws establish functional relationships between design parameters of a prototype and model sail that are created at different geometric sizes. This work is applied to a specific solar sail configuration and results in three (four) similarity criteria for static (dynamic) sail models. Further, it is demonstrated that even in the context of unique sail material requirements and gravitational load of earth-bound experiments, it is possible to develop appropriate scaled sail experiments. In the longer term, these scaling laws can be used in the design of scaled experimental tests for solar sails and in analyzing the results from such tests.

  17. Assessment of plasma anti-elastin antibodies for use as a diagnostic aid for chronic progressive lymphoedema in Belgian Draught Horses.

    PubMed

    De Keyser, K; Berth, M; Christensen, N; Willaert, S; Janssens, S; Ducatelle, R; Goddeeris, B M; De Cock, H E V; Buys, N

    2015-01-15

    Diagnosis of chronic progressive lymphoedema (CPL) in draught horses, including the Belgian Draught Horse, is mainly based on clinical evaluation of typical lower limb lesions. A deficient perilymphatic elastic support, caused by a pathological elastin degradation in skin and subcutis, has been suggested as a contributing factor for CPL. Elastin degradation products induce the generation of anti-elastin Ab (AEAb), detectable in horse serum by ELISA. For a clinically healthy group of draught horses, a significantly lower average AEAb-level than 3 clinically affected groups (mild, moderate and severe symptoms) was demonstrated previously. To improve CPL-diagnosis, we evaluated the AEAb-ELISA as an in vitro diagnostic aid in individual horses. Test reproducibility was assessed, performing assays independently in 2 laboratories on a total of 345 horses. Possible factors associated with AEAb-levels (age, gender, pregnancy, test lab and date of blood collection) were analyzed using a mixed statistical model. Results were reproducible in both laboratories. AEAb-levels in moderately and severely affected horses were significantly higher than in healthy horses. Nevertheless, this was only demonstrated in barren mares, and, there was a very large overlap between the clinical groups. Consequently, even when a high AEAb cut-off was handled to obtain a reasonable specificity of 90%, a very low sensitivity (21%) of AEAb for CPL-diagnosis was obtained. Results on the present sample demonstrate that the described ELISA procedure is of no use as a diagnostic test for CPL in individual horses. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Thermal and Fluid Modeling of the CRYogenic Orbital TEstbed (CRYOTE) Ground Test Article (GTA)

    NASA Technical Reports Server (NTRS)

    Piryk, David; Schallhorn, Paul; Walls, Laurie; Stopnitzky, Benny; Rhys, Noah; Wollen, Mark

    2012-01-01

    The purpose of this study was to anchor thermal and fluid system models to data acquired from a ground test article (GTA) for the CRYogenic Orbital TEstbed - CRYOTE. To accomplish this analysis, it was broken into four primary tasks. These included model development, pre-test predictions, testing support at Marshall Space Flight Center (MSFC} and post-test correlations. Information from MSFC facilitated the task of refining and correlating the initial models. The primary goal of the modeling/testing/correlating efforts was to characterize heat loads throughout the ground test article. Significant factors impacting the heat loads included radiative environments, multi-layer insulation (MLI) performance, tank fill levels, tank pressures, and even contact conductance coefficients. This paper demonstrates how analytical thermal/fluid networks were established, and it includes supporting rationale for specific thermal responses seen during testing.

  19. The Effects of Cold Whirlpool on Power, Speed, Agility, and Range of Motion

    PubMed Central

    Patterson, Stephen M.; Udermann, Brian E.; Doberstein, Scott T.; Reineke, David M.

    2008-01-01

    The purpose was to determine if cold whirlpool treatment decreases functional performance equally regardless of gender. A secondary aim was to determine if there is a gradual increase in functional performance across time. Twenty-one college-aged subjects volunteered to participate in this study and were required to perform four measures of functional performance including: counter movement vertical jump, T-test, 36.58-meter dash (40-yard), and active range of motion of the ankle. Participants were treated with a 20 minute, 10 degree Celsius cold whirlpool following the pre-test of a given functional performance measure. Participants demonstrated significant decreases in counter movement vertical jump, T-test, and 40-yard dash performance immediately following treatment. Vertical jump performance remained impaired for at least 32 minutes. While both the T-test and 40-yard dash were affected for 7 and 22 minutes post- treatment, respectively. Participants also demonstrated significant decreases in peak power and average power immediately after and for 32 minutes post-treatment. Dorsiflexion was significantly decreased 7 and 12 minutes following treatment. There were no differences for plantar flexion, inversion, or eversion. These data suggest functional performance was affected immediately following and for up to 32 minutes after cold whirlpool treatment. It was also evident that there is a gradual performance increase for each measure of functional performance across time. Therefore, the consequences should be carefully considered before returning athletes to activity following cold whirlpool treatment. Key pointsCryotherapy is a common and highly effective modality in treating acute and chronic athletic injuries.The results indicated that cold whirlpool does have an immediate and subsequent effect on functional performance.Understanding how cold whirlpool adversely affects functional performance allows clinicians to continue using this modality before vigorous athletic activity. PMID:24149907

  20. Fresh Osteochondral Allograft Versus Autograft: Twelve-Month Results in Isolated Canine Knee Defects.

    PubMed

    McCarty, Eric C; Fader, Ryan R; Mitchell, Justin J; Glenn, R Edward; Potter, Hollis G; Spindler, Kurt P

    2016-09-01

    Osteochondral autografts and allografts have been widely used in the treatment of isolated grade 4 articular cartilage lesions of the knee. However, there is a paucity of literature regarding the basic science investigating the direct comparison between fresh osteochondral allografts to autografts. At 12 months, fresh osteochondral allografts are equal to autografts with respect to function, bony incorporation into host bone, and chondrocyte viability. Controlled laboratory study. Eight adult mongrel dogs underwent bilateral hindlimb osteochondral graft implantation in the knee after creation of an acute Outerbridge grade 4 cartilage defect. One hindlimb of each dog knee received an autograft, and the contralateral knee received an allograft. All dogs were sacrificed at 12 months. Graft analysis included gross examination, radiographs, magnetic resonance imaging (MRI), biomechanical testing, and histology. MRI demonstrated excellent bony incorporation of both autografts and allografts, except for 1 allograft that revealed partial incorporation. Histologic examination of cartilage showed intact hyaline appearance for both autografts and allografts, with fibrocartilage at the host-graft interface of both. Biomechanical testing demonstrated no significant difference between allografts and autografts (P = .76). Furthermore, no significant difference was observed between allografts and the native cartilage with biomechanical testing (P = .84). After 12 months from time of implantation, fresh osteochondral allograft tissue and autograft tissue in this study were not statistically different with respect to biomechanical properties, gross morphology, bony incorporation, or overall histologic characteristics. When compared with the previously reported 6-month incorporation rates, there was improved allograft and autograft incorporation at 12 months. With no significant differences in gross examination, radiographs, MRI, biomechanical testing, or histology in the canine model, the use of allograft tissue to treat osteochondral defects may eliminate the morbidity associated with autograft harvest. © 2016 The Author(s).

  1. Effect of Motivational Interviewing on a Weight Loss Program Based on the Protection Motivation Theory.

    PubMed

    Mirkarimi, Kamal; Mostafavi, Firoozeh; Eshghinia, Samira; Vakili, Mohammad Ali; Ozouni-Davaji, Rahman Berdi; Aryaie, Mohammad

    2015-06-01

    The prevalence of overweight and obesity is on the increase the world over, which imposes an ever-increasing burden on societies and health care systems. This study sought to investigate the effect of motivational interviewing (MI) on a weight-loss program based on the protection motivation theory (PMT). This randomized clinical trial study, comprising pretest-posttest with a control group, was conducted on 150 overweight and obese women attending a private nutrition clinic for the first time. Samples were randomly selected using the clinic's records and then allocated to three groups (50 women in each group) receiving: 1) a standard weight-control program; 2) motivational interviewing; and 3) MI plus intention intervention. Data were collected using a researcher-made questionnaire through in-person interviews and were analyzed using SPSS (version 11) and statistical tests, including the Kruskal-Wallis test, one-way analysis of variance, paired t-test, and linear regression model. In the two intervention groups, the PMT construct scores, namely susceptibility (P = 0.001), severity (P = 0.001), rewards (P =0.004), self-efficacy (P = 0.001), response efficacy (P = 0.001), and costs (P = 0.014), were significantly increased compared to those in the control group. The anthropometric status was statistically significant in the MI group (P = 0.001) and the MI plus intention-intervention group (P = 0.001) at 2 months' follow-up, while in the control group, weight was meaningfully different after the intervention (P = 0.027). Weight was different between the groups after the intervention, with the Tukey test demonstrating that the differences were statistically significant between the control group and the MI group. Our results demonstrated that MI, combined with the implementation of intention intervention, increased weight loss and PMT construct scores in our study population.

  2. Measurement of dentin hypersensitivity with the Jay Sensitivity Sensor Probe and the Yeaple probe to compare relief from dentin hypersensitivity by dentifrices.

    PubMed

    Kakar, Ashish; Kakar, Kanupriya

    2013-05-01

    To compare relief from dentin hypersensitivity (DH) after use of dentifrices formulated with potassium nitrate or fluoride. For the study, DH evaluations were conducted with the Jay Sensitivity Sensor Probe (Jay Probe), a novel tactile hypersensitivity instrument, in conjunction with three other DH methods, i.e. Yeaple probe (tactile), air blast, and the Visual Analog Scale (VAS). Adults (n = 100) who presented two teeth with DH and met study criteria were enrolled for this double-blind, randomized, parallel, controlled clinical trial conducted in an outpatient setting. DH evaluations at baseline were conducted by the tactile, air blast, and VAS methods. Subjects were randomly assigned a dentifrice formulated with 5% potassium nitrate and 1,000 ppm fluoride (as sodium monofluorophosphate) (Colgate Sensitive toothpaste; Test) or a commercially available fluoride dentifrice with 1,000 ppm fluoride as sodium monofluorophosphate (Colgate Cibaca toothpaste; Negative control). Subjects were recalled for DH evaluations after 4 and 8 weeks of product use. 85 subjects completed the entire study with evaluable results. Both treatments resulted in significant reductions in DH from baseline to all recall visits. In comparison to the Negative control, subjects in the Test group demonstrated significantly greater reductions for all DH evaluations at both 4 and 8 weeks (P < 0.05). Average tactile DH scores at week 8 for the Test and Negative control groups were 36.25 and 15.24 with the Yeaple probe and 35 and 12.43 with the Jay probe. Correspondingly, subjects in the Test group demonstrated significantly greater reductions in air blast and VAS responses for DH than those in the Negative control group (P < 0.05).

  3. Demonstration of a Balloon Borne Arc-Second Pointer Design

    NASA Technical Reports Server (NTRS)

    DeWeese, Keith D.; Ward, Philip R.

    2006-01-01

    Many designs for utilizing stratospheric balloons as low-cost platforms on which to conduct space science experiments have been proposed throughout the years. A major hurdle in extending the range of experiments for which these vehicles are useful has been the imposition of the gondola dynamics on the accuracy with which an instrument can be kept pointed at a celestial target. A significant number of scientists have sought the ability to point their instruments with jitter in the arc-second range. This paper presents the design and analysis of a stratospheric balloon borne pointing system that is able to meet this requirement. The test results of a demonstration prototype of the design with similar ability are also presented. Discussion of a high fidelity controller simulation for design analysis is presented. The flexibility of the flight train is represented through generalized modal analysis. A multiple controller scheme is utilized for coarse and fine pointing. Coarse azimuth pointing is accomplished by an established pointing system, with extensive flight history, residing above the gondola structure. A pitch-yaw gimbal mount is used for fine pointing, providing orthogonal axes when nominally on target. Fine pointing actuation is from direct drive dc motors, eliminating backlash problems. An analysis of friction nonlinearities and a demonstration of the necessity in eliminating static friction are provided. A unique bearing hub design is introduced that eliminates static friction from the system dynamics. A control scheme involving linear accelerometers for enhanced disturbance rejection is also presented. Results from a linear analysis of the total system and the high fidelity simulation are given. Results from a generalized demonstration prototype are presented. Commercial off-the-shelf (COTS) hardware was used to demonstrate the efficacy and performance of the pointer design for a mock instrument. Sub-arcsecond pointing ability from a ground hang test setup is shown from the testing results. This paper establishes that the proposed control strategy can be made robustly stable with significant design margins. Also demonstrated is the efficacy of the proposed system in rejecting disturbances larger than those considered realistic. The system is implemented and demonstrates sub arc second pointing ability using COTS hardware. Finally, we see that sub arc-second pointing stability can be achieved for a large instrument pointing at an inertial target.

  4. Service tough composite structures using the Z-direction reinforcement process

    NASA Technical Reports Server (NTRS)

    Freitas, Glenn; Magee, Constance; Boyce, Joseph; Bott, Richard

    1992-01-01

    Foster-Miller has developed a new process to provide through thickness reinforcement of composite structures. The process reinforces laminates locally or globally on-tool during standard autoclave processing cycles. Initial test results indicate that the method has the potential to significantly reduce delamination in carbon-epoxy. Laminates reinforced with the z-fiber process have demonstrated significant improvements in mode 1 fracture toughness and compression strength after impact. Unlike alternative methods, in-plane properties are not adversely affected.

  5. Extrapolating Accelerated UV Weathering Data: Perspective From PVQAT Task Group 5 (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, D.; Annigoni, E.; Ballion, A.

    2015-02-01

    Taskgroup 5 (TG5) is concerned with a accelerated aging standard incorporating factors including ultraviolet radiation, temperature, and moisture. Separate experiments are being conducted in support of a test standard via the regional sub-groups in Asia, Europe, and the United States. The authors will describe the objectives and timeline for the TG5 interlaboratory study being directed out of the USA. Qualitative preliminary data from the experiment is presented. To date, the encapsulation transmittance experiment has: replicated behaviors of fielded materials (including specimen location- and formulation additive-specific discoloration); demonstrated coupling between UV aging and temperature; demonstrated that degradation in EVA results frommore » UV- aging; and obtained good qualitative comparison between Xe and UVA-340 sources for EVA. To date, the encapsulation adhesion experiment (using the compressive shear test to quantify strength of attachment) has demonstrated that attachment strength can decrease drastically (>50%) with age; however, early results suggest significant factor (UV, T, RH) dependence. Much remains to be learned about adhesion.« less

  6. Immunopathogenesis of fish allergy: identification of fish-allergic adults by skin test and radioallergosorbent test.

    PubMed

    Helbling, A; McCants, M L; Musmand, J J; Schwartz, H J; Lehrer, S B

    1996-07-01

    As the consumption of fish increases in the United States, the importance of allergic reactions to fish has become clear. Since most previous studies on fish allergy have focused on children reacting mainly to codfish, there is a need to investigate allergic reactions to other fish in adults. To identify fish-allergic adults, and to assess cross-reactivity among different species of fish by RAST inhibition. Thirty-nine individuals who reported fish allergy were selected for study; 32 (82%) were atopic as defined by two or more positive skin tests to common inhalant allergens and a history of allergic reactions and 33 (85%) experienced allergic symptoms within 30 minutes after ingesting fish. The most frequently reported symptoms were hives (69%), itching (69%), and wheezing/chest tightness (54%). Study subjects were skin tested with fish extracts and their sera assayed for IgE antibodies to different fish species. Thirty-six (92%) of the subjects tested had a positive skin test to at least one of 17 fish extracts tested; 9/35 (26%) reacted to all 17 extracts. Of the atopic (two or more positive skin tests to common inhalant allergens plus a personal and/or family history of allergy) and nonatopic fish-tolerant controls, 20/26 (77%) reacted by skin test to one or more fish extracts tested; the most prevalent positive reaction was to anchovy (73%). A significant correlation (P < .01) was observed between skin test reactivity of fish-allergic subjects to most fish extracts and fish RAST reactions. Radioallergosorbent inhibition testing demonstrated significant cross-reactivity among pollack, salmon, trout, and tuna; and between mackerel and anchovy. These results suggest that fish-allergic subjects may be clinically sensitive to more than one species of fish. Skin test reactivity to fish by itself is not an adequate criterion for the confirmation of clinically relevant fish allergy; consequently, fish-allergic subjects with positive skin tests to several fish species should exercise caution when eating fish until tolerance can be demonstrated by double-blind, placebo-controlled food challenge, at the patient's earliest convenience.

  7. Bihemispheric cerebral FDG PET correlates of cognitive dysfunction as assessed by the CERAD in Alzheimer's disease.

    PubMed

    Schönknecht, Oskar Dieter Peter; Hunt, Aoife; Toro, Pablo; Guenther, Thomas; Henze, Marcus; Haberkorn, Uwe; Schröder, Johannes

    2011-04-01

    Alzheimer's disease (AD) is characterized by a variety of cognitive deficits which can be reliably assessed by the neuropsychological test battery of the Consortium to Establish a Registry for Alzheimer's Disease (CERAD), but the cerebral changes underlying the respective cognitive deficits are only partly understood. Measures of severity of dementia in AD as well as delayed episodic memory performance in mild cognitive impairment significantly correlated with bihemispheric cerebral glucose hypometabolism. We therefore hypothesized that the CERAD cognitive battery may represent cerebral dysfunction of both hemispheres in patients with AD. In 32 patients with AD, cerebral glucose metabolism was investigated using positron-emission-tomography with 18Fluorodeoxyglucose (FDG PET) and associated with the test scores of the CERAD cognitive battery by statistical parametric mapping. Episodic memory scores significantly correlated with temporopari etal glucose metabolism of both hemispheres while delayed episodic memory significantly was correlated with the right frontotemporal cortices. Verbal fluency and naming scores significantly correlated with glucose metabolism in left temporoparietal and right frontal cortices, whereas constructional praxis predominantly correlated significantly with the bilateral precuneus. In conclusion, the results of our study demonstrate that not only memory function but also functions of language and constructional praxis in AD are associated with glucose metabolism as revealed by FDG PET in subsets of uni- and bilateral brain areas. The findings of our study for the first time demonstrate that in AD neuropsychological deficits as assessed by the CERAD refer to different cerebral sites of both hemispheres.

  8. Estimation of the level of anxiety in rats: differences in results of open-field test, elevated plus-maze test, and Vogel's conflict test.

    PubMed

    Sudakov, S K; Nazarova, G A; Alekseeva, E V; Bashkatova, V G

    2013-07-01

    We compared individual anxiety assessed by three standard tests, open-field test, elevated plus-maze test, and Vogel conflict drinking test, in the same animals. No significant correlations between the main anxiety parameters were found in these three experimental models. Groups of animals with high and low anxiety rats were formed by a single parameter and subsequent selection of two extreme groups (10%). It was found that none of the tests could be used for reliable estimation of individual anxiety in rats. The individual anxiety level with high degree of confidence was determined in high-anxiety and low-anxiety rats demonstrating behavioral parameters above and below the mean values in all tests used. Therefore, several tests should be used for evaluation of the individual anxiety or sensitivity to emotional stress.

  9. Acquisition/expulsion system for earth orbital propulsion system study. Volume 3: Cryogenic test

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A ground test program was conducted to verify several of the design methods and techniques that were used in designing cryogenic acquisition/expulsion systems. The testing of a 63.5-cm diameter DSL subscale model was particularly significant. Under these tests, the operational characteristics of the DSL concept were verified using LH2 and LN2. Demonstration of the gas free liquid expulsion characteristics was accomplished by expelling LH2 under -1 g using both GH2 and GHe pressurization. Loading of the acquisition/expulsion device was successfully accomplished using LH2 and LN2. The liquid free vapor venting performance of the model was limited because of the thermal stratification under the -1 g test conditions.

  10. Repeat tuberculin skin testing leads to desensitisation in naturally infected tuberculous cattle which is associated with elevated interleukin-10 and decreased interleukin-1 beta responses.

    PubMed

    Coad, Michael; Clifford, Derek; Rhodes, Shelley G; Hewinson, R Glyn; Vordermeier, H Martin; Whelan, Adam O

    2010-01-01

    The principal surveillance tool used to control bovine tuberculosis in cattle is the removal of animals that provide a positive response to the tuberculin skin-test. In this study we performed a longitudinal investigation of the immunological and diagnostic consequences of repeated short-interval skin-tests in cattle naturally infected with Mycobacterium bovis. Tuberculin skin-test positive cattle were subjected to up to four further intradermal comparative cervical skin-tests at approximately 60-day intervals. A significant progressive reduction in the strength of the skin-test was observed after successive tests. In contrast, the magnitude of interferon-gamma (IFN-gamma) responses was not influenced by repeat skin-testing either transiently around the time of each skin-test or longitudinally following repeated tests. A significant boost in blood interleukin-10 (IL-10) production was observed within 3 days following each skin-test although the magnitude of this boosted response returned to lower levels by day 10 post-test. The application of a novel multiplex assay to simultaneously measure seven cytokines and chemokines also identified that skin-testing resulted in a significant and progressive reduction in antigen specific interleukin-1beta (IL-1beta) whilst confirming stable IFN-gamma and elevated IL-10 responses in the blood. Therefore, we have demonstrated that in cattle naturally infected with M. bovis, repeat short-interval skin-testing can lead to a progressive reduction in skin-test responsiveness which has potential negative consequences for the detection of infected animals with marginal or inconclusive skin-test responses. The desensitising effect is associated with decreased IL-1beta and elevated IL-10 responses, but importantly, does not influence antigen specific IFN-gamma responses. INRA, EDP Sciences, 2009

  11. Pathways to Mathematics College Readiness in Maine

    ERIC Educational Resources Information Center

    Silvernail, David L; Batista, Ida A.; Sloan, James E.; Stump, Erika K.; Johnson, Amy F.

    2014-01-01

    The goal of this study was to examine the pathways to being college ready in mathematics. Students who enter high school already having demonstrated mathematics proficiency on a standardized test in the 8th grade have already taken a significant step towards being college ready. The best scenario is to enter high school proficient in mathematics…

  12. Rapid detection of serum antibody by dual-path platform VetTB assay in white-tailed deer infected with Mycobacterium bovis

    USDA-ARS?s Scientific Manuscript database

    Bovine tuberculosis (TB) in various cervid species remains a significant problem affecting both farmed herds and free-ranging populations. Traditional skin testing was demonstrated to have serious limitations in certain deer species, whereas emerging serological assays showed promising diagnostic pe...

  13. NASA Office of Aeronautics and Space Technology Summer Workshop. Executive summary. [in-space research using the Space Transportation System

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Research and technology investigations are identified in eleven discipline technologies which require or which could significantly benefit from an in-space experiment, systems demonstrations, or component test using the Space Transportation System. Synopses of the eleven technology panels reports are presented.

  14. The Induction of Emergent Relations in Children with Severe Cognitive and Language Delays

    ERIC Educational Resources Information Center

    Howarth, Matthew

    2012-01-01

    In three experiments I sought to experimentally test a source of emergent relations defined as transitivity by Stimulus Equivalence theory or as combinatorial entailment in Relational Frame Theory. In Experiment I, the participants were 4 children diagnosed with autism who also demonstrated significant cognitive and language delays, who were…

  15. Examining Gender and the Academic Achievement of Students with Emotional Disturbance

    ERIC Educational Resources Information Center

    Rice, Elisabeth Hess; Yen, Cherng-Jyh

    2010-01-01

    Students with emotional disturbance (ED) have significant academic deficits (Trout, Nordness, Pierce, & Epstein, 2003; Lane, 2004). Even after identification and school intervention, students with ED continue to demonstrate limited academic achievement and high rates of drop out and school failure, with 80-90% scoring below grade level on tests of…

  16. The democratization of the oncogene.

    PubMed

    Le, Anh T; Doebele, Robert C

    2014-08-01

    The identification of novel, oncogenic gene rearrangements in inflammatory myofibroblastic tumor demonstrates the potential of next-generation sequencing (NGS) platforms for the detection of therapeutically relevant oncogenes across multiple tumor types, but raises significant questions relating to the investigation of targeted therapies in this new era of widespread NGS testing. ©2014 American Association for Cancer Research.

  17. Reducing the Effect of Stereotype Threat: The Role of Coaction Contexts and Regulatory Fit

    ERIC Educational Resources Information Center

    Wen, Fangfang; Zuo, Bin; Wu, Yang; Dong, Xuanhao; Wang, Wei

    2016-01-01

    Two experiments examined the effects of competition and cooperation contexts, as well as regulatory fit, on reducing the negative influence of stereotype threat. Experiment 1 demonstrated that in high stereotype threat conditions, participants in the cooperation context scored significantly higher on a math test than those in the competition…

  18. Argumentation Based Bioethics Education: Sample Implementation on Genetically Modified Organisms (GMOs) and Genetic Screening Tests

    ERIC Educational Resources Information Center

    Ozer Keskin, Melike; Keskin Samanci, Nilay; Yaman, Hale

    2013-01-01

    Nowadays, there is a need in science education to consider scientific research and its applications alongside ethical consensus. Even though classroom debates of value issues have been demonstrated to significantly contribute to the raising of social consciousness and awareness, research shows that neither academics in higher education nor…

  19. Acidic fog and temperature effects on stigmatic receptivity in two birch species

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hughes, R.N.; Cox, R.M.

    Factorial assays were performed to determine the effects of simulated acid fog (SAF) and temperature on stigmatic receptivity in two birch species. Excised reproductive branches were sampled from representative individuals of mountain paper birch (Betula cordifolia Regel.) and paper birch (Betula papyrifera Marsh.) in populations adjacent to the Bay of Fundy, New Brunswick, Canada. Since 1979 these trees have exhibited branch dieback in association with abnormal foliar browning symptoms. This browning has been linked with acidity and nitrate deposited by fog, which is frequent in the area. In general, experimental results indicated that pollen germination increased with temperature, but pHmore » effects were less obvious. Similarly, pollen tube growth responded positively to temperature and was little affected by fog acidity. ANOVA tests indicated a significant difference (P < 0.05) between species in their pollen germination response only at 12{degrees}C, and not at the other three temperatures tested. For pollen tube growth, significant differences between species (P < 0.05) were demonstrated at 12 and 22{degrees}C. A significant pH effect was demonstrated at 27{degrees}C for germination, while pH effects on tube growth were significant at 27 and 12{degrees}C (P < 0.01). A response surface regression analysis indicated that acidity significantly affected pollen germination in mountain paper birch (P < 0.001) but not in paper birch. Temperature was not a significant factor for in vivo pollen germination in either species. For pollen tube growth, however, temperature was more important than pH and produced highly significant effects in both species (P < 0.001). Acidity was also a significant factor in pollen tube growth for paper birch. 39 refs., 4 figs., 3 tabs.« less

  20. Evaluation of Anti-Candida Activity of Vitis vinifera L. Seed Extracts Obtained from Wine and Table Cultivars

    PubMed Central

    Santamaria, Anna Rita; D'Auria, Felicia Diodata; Innocenti, Marzia; Gabrielli, Elena; Panella, Simona; Antonacci, Donato; Palamara, Anna Teresa; Vecchiarelli, Anna

    2014-01-01

    For the first time, grape seed extracts (GSEs), obtained from wine and table cultivars of Vitis vinifera L., cultured in experimental fields of Lazio and Puglia regions of Italy and grown in different agronomic conditions, have been tested on 43 Candida species strains. We demonstrated a significant correlation between the content of the flavan-3-ols in GSEs extracts, with a polymerization degree ≥4, and anti-Candida activity. Moreover, we demonstrated that GSEs, obtained from plants cultured with reduced irrigation, showed a content of polymeric flavan-3-ols >250 mg/g with geometric mean MIC values between 5.7 and 20.2 mg/L against Candida albicans reference strains. GSE, showing 573 mg/g of polymeric flavan-3-ols, has been tested in an experimental murine model of vaginal candidiasis by using noninvasive in vivo imaging technique. The results pointed out a significant inhibition of Candida albicans load 5 days after challenge. These findings indicate that GSEs with high content of polymeric flavan-3-ols can be used in mucosal infection as vaginal candidiasis. PMID:24864227

  1. Effects of prolonged agmatine treatment in aged male Sprague-Dawley rats.

    PubMed

    Rushaidhi, M; Zhang, H; Liu, P

    2013-03-27

    Increasing evidence suggests that altered arginine metabolism contributes to cognitive decline during ageing. Agmatine, decarboxylated arginine, has a variety of pharmacological effects, including the modulation of behavioural function. A recent study demonstrated the beneficial effects of short-term agmatine treatment in aged rats. The present study investigated how intraperitoneal administration of agmatine (40mg/kg, once daily) over 4-6weeks affected behavioural function and neurochemistry in aged Sprague-Dawley rats. Aged rats treated with saline displayed significantly reduced exploratory activity in the open field, impaired spatial learning and memory in the water maze and object recognition memory relative to young rats. Prolonged agmatine treatment improved animals' performance in the reversal test of the water maze and object recognition memory test, and significantly suppressed age-related elevation in nitric oxide synthase activity in the dentate gyrus of the hippocampus and prefrontal cortex. However, this prolonged supplementation was unable to improve exploratory activity and spatial reference learning and memory in aged rats. These findings further demonstrate that exogenous agmatine selectively improves behavioural function in aged rats. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.

  2. [Study on secondary metabolites of marine fungus Penicillium sp. FS60 from the South China Sea].

    PubMed

    Zhang, Ling; Li, Dong-Li; Chen, Yu-Chan; Tao, Mei-Hua; Zhang, Wei-Min

    2012-07-01

    To study the secondary metabolites of the marine fungus Penicillium sp. FS60 from the South China Sea and their cytotoxicities. The compounds were isolated from the culture of strain FS60 by various chromatographic methods (silica gel, reverse silica gel, Sephadex-LH20, preparative TLC, HPLC and PTLC) and recrystallization. Their structures were identified by extensive analysis of their spectroscopic data. Compounds were tested for their cytotoxicities against SF-268, MCF-7, and NCI-H460 cell lines by SRB method. While, Compounds were tested for their antibacterial activities against S. aureus, E. coli and P. aeruginosa. Seven compounds were isolated from the culture and identified as methyl 2,4-dihydroxy-3,5,6-trimethylbenzoate (1), 4-hydroxyacetophenone (2), 5-hydroxymethyl-furoic acid (3), isochromophilones VIII (4), ergosterol (5), ergosterol peroxide (6), and cerevisterol (7). Compound 1 is isolated from the genus Penicillium for the first time. Compound 3 is demonstrated to have significant inhibition against S. aureus and P. aeruginosa. Compound 4 is demonstrated to have significant inhibition against the three cell lines.

  3. A Simple Test of Class-Level Genetic Association Can Reveal Novel Cardiometabolic Trait Loci.

    PubMed

    Qian, Jing; Nunez, Sara; Reed, Eric; Reilly, Muredach P; Foulkes, Andrea S

    2016-01-01

    Characterizing the genetic determinants of complex diseases can be further augmented by incorporating knowledge of underlying structure or classifications of the genome, such as newly developed mappings of protein-coding genes, epigenetic marks, enhancer elements and non-coding RNAs. We apply a simple class-level testing framework, termed Genetic Class Association Testing (GenCAT), to identify protein-coding gene association with 14 cardiometabolic (CMD) related traits across 6 publicly available genome wide association (GWA) meta-analysis data resources. GenCAT uses SNP-level meta-analysis test statistics across all SNPs within a class of elements, as well as the size of the class and its unique correlation structure, to determine if the class is statistically meaningful. The novelty of findings is evaluated through investigation of regional signals. A subset of findings are validated using recently updated, larger meta-analysis resources. A simulation study is presented to characterize overall performance with respect to power, control of family-wise error and computational efficiency. All analysis is performed using the GenCAT package, R version 3.2.1. We demonstrate that class-level testing complements the common first stage minP approach that involves individual SNP-level testing followed by post-hoc ascribing of statistically significant SNPs to genes and loci. GenCAT suggests 54 protein-coding genes at 41 distinct loci for the 13 CMD traits investigated in the discovery analysis, that are beyond the discoveries of minP alone. An additional application to biological pathways demonstrates flexibility in defining genetic classes. We conclude that it would be prudent to include class-level testing as standard practice in GWA analysis. GenCAT, for example, can be used as a simple, complementary and efficient strategy for class-level testing that leverages existing data resources, requires only summary level data in the form of test statistics, and adds significant value with respect to its potential for identifying multiple novel and clinically relevant trait associations.

  4. Unstructured Adaptive Grid Computations on an Array of SMPs

    NASA Technical Reports Server (NTRS)

    Biswas, Rupak; Pramanick, Ira; Sohn, Andrew; Simon, Horst D.

    1996-01-01

    Dynamic load balancing is necessary for parallel adaptive methods to solve unsteady CFD problems on unstructured grids. We have presented such a dynamic load balancing framework called JOVE, in this paper. Results on a four-POWERnode POWER CHALLENGEarray demonstrated that load balancing gives significant performance improvements over no load balancing for such adaptive computations. The parallel speedup of JOVE, implemented using MPI on the POWER CHALLENCEarray, was significant, being as high as 31 for 32 processors. An implementation of JOVE that exploits 'an array of SMPS' architecture was also studied; this hybrid JOVE outperformed flat JOVE by up to 28% on the meshes and adaption models tested. With large, realistic meshes and actual flow-solver and adaption phases incorporated into JOVE, hybrid JOVE can be expected to yield significant advantage over flat JOVE, especially as the number of processors is increased, thus demonstrating the scalability of an array of SMPs architecture.

  5. Influence of solid-liquid separation method parameters employed in soil leaching tests on apparent metal concentration.

    PubMed

    Imoto, Yukari; Yasutaka, Tetsuo; Someya, Masayuki; Higashino, Kazuo

    2018-05-15

    Soil leaching tests are commonly used to evaluate the leachability of hazardous materials, such as heavy metals, from the soil. Batch leaching tests often enhance soil colloidal mobility and may require solid-liquid separation procedures to remove excess soil particles. However, batch leaching test results depend on particles that can pass through a 0.45μm membrane filter and are influenced by test parameters such as centrifugal intensity and filtration volume per filter. To evaluate these parameters, we conducted batch leaching experiments using metal-contaminated soils and focused on the centrifugal intensity and filtration volume per filter used in solid-liquid separation methods currently employed in standard leaching tests. Our experiments showed that both centrifugal intensity and filtration volume per filter affected the reproducibility of batch leaching tests for some soil types. The results demonstrated that metal concentrations in the filtrates significantly differed according to the centrifugal intensity when it was 3000 g for 2h or less. Increased filtration volume per filter led to significant decreases in filtrate metal concentrations when filter cakes formed during filtration. Comparison of the filtration tests using 0.10 and 0.45μm membrane filters showed statistically significant differences in turbidity and metal concentration. These findings suggest that colloidal particles were not adequately removed from the extract and contributed substantially to the apparent metal concentrations in the leaching test of soil containing colloidal metals. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Co-registration of ultrasound and frequency-domain photoacoustic radar images and image improvement for tumor detection

    NASA Astrophysics Data System (ADS)

    Dovlo, Edem; Lashkari, Bahman; Choi, Sung soo Sean; Mandelis, Andreas

    2015-03-01

    This paper demonstrates the co-registration of ultrasound (US) and frequency domain photoacoustic radar (FD-PAR) images with significant image improvement from applying image normalization, filtering and amplification techniques. Achieving PA imaging functionality on a commercial Ultrasound instrument could accelerate clinical acceptance and use. Experimental results presented demonstrate live animal testing and show enhancements in signal-to-noise ratio (SNR), contrast and spatial resolution. The co-registered image produced from the US and phase PA images, provides more information than both images independently.

  7. Optimal periodic proof test based on cost-effective and reliability criteria

    NASA Technical Reports Server (NTRS)

    Yang, J.-N.

    1976-01-01

    An exploratory study for the optimization of periodic proof tests for fatigue-critical structures is presented. The optimal proof load level and the optimal number of periodic proof tests are determined by minimizing the total expected (statistical average) cost, while the constraint on the allowable level of structural reliability is satisfied. The total expected cost consists of the expected cost of proof tests, the expected cost of structures destroyed by proof tests, and the expected cost of structural failure in service. It is demonstrated by numerical examples that significant cost saving and reliability improvement for fatigue-critical structures can be achieved by the application of the optimal periodic proof test. The present study is relevant to the establishment of optimal maintenance procedures for fatigue-critical structures.

  8. An EMTP system level model of the PMAD DC test bed

    NASA Technical Reports Server (NTRS)

    Dravid, Narayan V.; Kacpura, Thomas J.; Tam, Kwa-Sur

    1991-01-01

    A power management and distribution direct current (PMAD DC) test bed was set up at the NASA Lewis Research Center to investigate Space Station Freedom Electric Power Systems issues. Efficiency of test bed operation significantly improves with a computer simulation model of the test bed as an adjunct tool of investigation. Such a model is developed using the Electromagnetic Transients Program (EMTP) and is available to the test bed developers and experimenters. The computer model is assembled on a modular basis. Device models of different types can be incorporated into the system model with only a few lines of code. A library of the various model types is created for this purpose. Simulation results and corresponding test bed results are presented to demonstrate model validity.

  9. Auditory sequence analysis and phonological skill

    PubMed Central

    Grube, Manon; Kumar, Sukhbinder; Cooper, Freya E.; Turton, Stuart; Griffiths, Timothy D.

    2012-01-01

    This work tests the relationship between auditory and phonological skill in a non-selected cohort of 238 school students (age 11) with the specific hypothesis that sound-sequence analysis would be more relevant to phonological skill than the analysis of basic, single sounds. Auditory processing was assessed across the domains of pitch, time and timbre; a combination of six standard tests of literacy and language ability was used to assess phonological skill. A significant correlation between general auditory and phonological skill was demonstrated, plus a significant, specific correlation between measures of phonological skill and the auditory analysis of short sequences in pitch and time. The data support a limited but significant link between auditory and phonological ability with a specific role for sound-sequence analysis, and provide a possible new focus for auditory training strategies to aid language development in early adolescence. PMID:22951739

  10. The relationship between fibre post geometry and flexural properties: an assessment through a modified three-point bending test.

    PubMed

    Soares, L P; de Vasconcellos, A B; da Silva, A H Monteiro da Fonseca Thomé; Sampaio, E M; Vianna, G A de Deus Carneiro

    2010-12-01

    The aim of this study was to investigate the flexural properties of five types of fiber-reinforced dowels using a modified three-point bending test. Fiber-reinforced resin dowels were tested by a modified three-point bending test associated with models for cylindrical and conical simple-supported beams. The fracture load ranged from 86 to 246 N and the flexural strength from 423 to 1192 MPa. FRC Postec had significantly higher flexural strength and fracture loads values. Thus, the present study demonstrated higher flexural strength values for the FRC Postec fibre posts, suggesting that this system would present a better response to the forces of mastication.

  11. Fail Safe, High Temperature Magnetic Bearings

    NASA Technical Reports Server (NTRS)

    Minihan, Thomas; Palazzolo, Alan; Kim, Yeonkyu; Lei, Shu-Liang; Kenny, Andrew; Na, Uhn Joo; Tucker, Randy; Preuss, Jason; Hunt, Andrew; Carter, Bart; hide

    2002-01-01

    This paper contributes to the magnetic bearing literature in two distinct areas: high temperature and redundant actuation. Design considerations and test results are given for the first published combined 538 C (1000 F) high speed rotating test performance of a magnetic bearing. Secondly, a significant extension of the flux isolation based, redundant actuator control algorithm is proposed to eliminate the prior deficiency of changing position stiffness after failure. The benefit of the novel extension was not experimentally demonstrated due to a high active stiffness requirement. In addition, test results are given for actuator failure tests at 399 C (750 F), 12,500 rpm. Finally, simulation results are presented confirming the experimental data and validating the redundant control algorithm.

  12. PRDA-2 and 3 Brush Seal Development Programs at EG and G

    NASA Technical Reports Server (NTRS)

    Loewenthal, Robert G.

    1996-01-01

    EG&G Mechanical Components Technology Group R&D completed a Brush Seal Development Program under PRDA-2 in late 1992. We started the Advanced Brush Seal Development program, under PRDA-3, in 1993 and will complete it in 1996. Both programs have been funded by the United States Air Force. In the first program, we made significant gains in the area of tribopairs (bristle materials vs. shaft coatings) and the 'Low Hysteresis' design for brush seals. These were reported in two AIAA Propulsion Conference papers, and the 'Low Hysteresis' design has been patented. Seals were delivered for test in an Air Force demonstrator at Allison. In PRDA-3, goals are to increase the pressure sealing capability, and the surface speeds and temperatures at which brush seals can be used. We have conducted part of the design and testing and have tested brush seals successfully at more severe conditions than in the previous program. We are continuing with the program, and will complete it in time to furnish brush seals for an Air Force Demonstrator test in 1997.

  13. Expert Reliability for the World Health Organization Standardized Ultrasound Classification of Cystic Echinococcosis

    PubMed Central

    Solomon, Nadia; Fields, Paul J.; Tamarozzi, Francesca; Brunetti, Enrico; Macpherson, Calum N. L.

    2017-01-01

    Cystic echinococcosis (CE), a parasitic zoonosis, results in cyst formation in the viscera. Cyst morphology depends on developmental stage. In 2003, the World Health Organization (WHO) published a standardized ultrasound (US) classification for CE, for use among experts as a standard of comparison. This study examined the reliability of this classification. Eleven international CE and US experts completed an assessment of eight WHO classification images and 88 test images representing cyst stages. Inter- and intraobserver reliability and observer performance were assessed using Fleiss' and Cohen's kappa. Interobserver reliability was moderate for WHO images (κ = 0.600, P < 0.0001) and substantial for test images (κ = 0.644, P < 0.0001), with substantial to almost perfect interobserver reliability for stages with pathognomonic signs (CE1, CE2, and CE3) for WHO (0.618 < κ < 0.904) and test images (0.642 < κ < 0.768). Comparisons of expert performances against the majority classification for each image were significant for WHO (0.413 < κ < 1.000, P < 0.005) and test images (0.718 < κ < 0.905, P < 0.0001); and intraobserver reliability was significant for WHO (0.520 < κ < 1.000, P < 0.005) and test images (0.690 < κ < 0.896, P < 0.0001). Findings demonstrate moderate to substantial interobserver and substantial to almost perfect intraobserver reliability for the WHO classification, with substantial to almost perfect interobserver reliability for pathognomonic stages. This confirms experts' abilities to reliably identify WHO-defined pathognomonic signs of CE, demonstrating that the WHO classification provides a reproducible way of staging CE. PMID:28070008

  14. Elevated cranial ultrasound resistive indices are associated with improved neurodevelopmental outcomes one year after pediatric cardiac surgery: A single center pilot study.

    PubMed

    Jenks, Christopher L; Hernandez, Ana; Stavinoha, Peter L; Morris, Michael C; Tian, Fenghua; Liu, Hanli; Garg, Parvesh; Forbess, Joseph M; Koch, Joshua

    To determine if a non-invasive, repeatable test can be used to predict neurodevelopmental outcomes in patients with congenital heart disease. This was a prospective study of pediatric patients less than two months of age undergoing congenital heart surgery at the Children's Health Children's Medical Center at Dallas. Multichannel near-infrared spectroscopy (NIRS) was utilized during the surgery, and ultrasound (US) resistive indices (RI) of the major cranial vessels were obtained prior to surgery, immediately post-operatively, and prior to discharge. Pearson's correlation, Fischer exact t test, and Fischer r to z transformation were used where appropriate. A total of 16 patients were enrolled. All had US data. Of the sixteen patients, two died prior to the neurodevelopmental testing, six did not return for the neurodevelopmental testing, and eight patients completed the neurodevelopmental testing. There were no significant correlations between the prior to surgery and prior to discharge US RI and neurodevelopmental outcomes. The immediate post-operative US RI demonstrated a strong positive correlation with standardized neurodevelopmental outcome measures. We were able to demonstrate qualitative differences using multichannel NIRS during surgery, but experienced significant technical difficulties implementing consistent monitoring. A higher resistive index in the major cerebral blood vessels following cardiac surgery in the neonatal period is associated with improved neurological outcomes one year after surgery. Obtaining an ultrasound with resistive indices of the major cerebral vessels prior to and after surgery may yield information that is predictive of neurodevelopmental outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Comparison of air-charged and water-filled urodynamic pressure measurement catheters.

    PubMed

    Cooper, M A; Fletter, P C; Zaszczurynski, P J; Damaser, M S

    2011-03-01

    Catheter systems are utilized to measure pressure for diagnosis of voiding dysfunction. In a clinical setting, patient movement and urodynamic pumps introduce hydrostatic and motion artifacts into measurements. Therefore, complete characterization of a catheter system includes its response to artifacts as well its frequency response. The objective of this study was to compare the response of two disposable clinical catheter systems: water-filled and air-charged, to controlled pressure signals to assess their similarities and differences in pressure transduction. We characterized frequency response using a transient step test, which exposed the catheters to a sudden change in pressure; and a sinusoidal frequency sweep test, which exposed the catheters to a sinusoidal pressure wave from 1 to 30 Hz. The response of the catheters to motion artifacts was tested using a vortex and the response to hydrostatic pressure changes was tested by moving the catheter tips to calibrated heights. Water-filled catheters acted as an underdamped system, resonating at 10.13 ± 1.03 Hz and attenuating signals at frequencies higher than 19 Hz. They demonstrated significant motion and hydrostatic artifacts. Air-charged catheters acted as an overdamped system and attenuated signals at frequencies higher than 3.02 ± 0.13 Hz. They demonstrated significantly less motion and hydrostatic artifacts than water-filled catheters. The transient step and frequency sweep tests gave comparable results. Air-charged and water-filled catheters respond to pressure changes in dramatically different ways. Knowledge of the characteristics of the pressure-measuring system is essential to finding the best match for a specific application. Copyright © 2011 Wiley-Liss, Inc.

  16. Assessment of rotation thromboelastometry parameters in patients with essential thrombocythemia at diagnosis and after hydroxyurea therapy.

    PubMed

    Treliński, Jacek; Okońska, Marta; Robak, Marta; Chojnowski, Krzysztof

    2016-03-01

    Patients with essential thrombocythemia suffer from thrombotic complications that are the main source of mortality. Due to its complex pathogenesis, no existing single laboratory method is able to identify the patients at highest risk for developing thrombosis. Twenty patients with essential thrombocythemia at diagnosis, 15 healthy volunteers and 20 patients treated with hydroxyurea were compared with regard to certain rotation thromboelastometry parameters. Clotting time (CT), clot formation time (CFT), α-angle, and maximum clot firmness (MCF) were assessed by using the INTEM, EXTEM, FIBTEM, and NATEM tests. Patients with essential thrombocythemia at diagnosis demonstrated significantly higher mean platelet count and markedly lower mean red blood count than controls. CT and CFT readings were found to be markedly lower in essential thrombocythemia patients at diagnosis than in the control group according to the EXTEM test. Patients at diagnosis had markedly lower CT values (EXTEM, FIBTEM) than patients on hydroxyurea therapy. Alpha angle values were markedly higher in essential thrombocythemia patients at diagnosis than in controls, according to the EXTEM, FIBTEM and NATEM tests. MCF readings were significantly higher in essential thrombocythemia patients at diagnosis than in controls according to EXTEM, INTEM, FIBTEM, and NATEM tests. Patients on hydroxyurea therapy had markedly lower MCF values according to EXTEM test than patients at diagnosis. Patients with essential thrombocythemia demonstrate a prothrombotic state at the time of diagnosis, which is reflected in changes by certain rotation thromboelastometry parameters. The hydroxyurea therapy induces downregulation of the prothrombotic features seen in essential thrombocythemia patients at diagnosis.

  17. The effect of repeated testing vs repeated practice on skills learning in undergraduate dental education.

    PubMed

    Sennhenn-Kirchner, S; Goerlich, Y; Kirchner, B; Notbohm, M; Schiekirka, S; Simmenroth, A; Raupach, T

    2018-02-01

    Recent studies in undergraduate medical education have demonstrated the advantage of repeated testing over repeated practice with regard to knowledge and skills retention. The aim of this study was to investigate whether this "testing effect" also applies to skills retention in undergraduate dental education. In this prospective, randomised controlled trial, fourth-year dental students at Göttingen University Medical Centre participated in a training session on surgical suturing in winter term 2014/2015. Following this, they were either assigned to two sessions of additional skills training (group A) or two sessions of skills assessment with feedback (group B). These sessions were spaced over a period of 4 weeks. Skills retention was assessed in a summative objective structured clinical examination (OSCE) at the end of term, that is 6 months after the initial teaching session. A total of 32 students completed the study. With regard to suturing, OSCE performance was significantly better in group B than group A (81.9±13.1% vs 63.0±15.4%; P=0.001; Cohen's d=1.33). There was no significant OSCE performance difference in the two groups with regard to other learning objectives that were addressed in the end-of-term examination. Thus, the group difference was specific to suturing skills. This is the first study to demonstrate that in dental education, repeated testing produces more favourable skills retention than repeated practice. Test-enhanced learning might be a viable concept for skills retention in undergraduate dentistry education. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Elastomer liners for geothermal tubulars Y267 EPDM Liner Program:

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirasuna, A.R.; Davis, D.L.; Flickinger, J.E.

    1987-12-01

    The elastomer, Y267 EPDM, has been identified as a hydrothermally stable material which can operate at temperatures in excess of 320/sup 0/C. The goal of the Y267 Liner Program was to demonstrate the feasibility of using this material as a liner for mild steel tubulars to prevent or mitigate corrosion. If successful, the usage of EPDM lined pipe by the geothermal community may have a significant impact on operating costs and serve as a viable alternative to the use of alloyed tubulars. Tooling procedures were developed under this program to mold a 0.64 cm (0.25'') thick Y267 EPDM liner intomore » a tubular test section 61 cm (2') in length and 19.1 cm (7.5'') in diameter (ID). A successful effort was made to identify a potential coupling agent to be used to bond the elastomer to the steel tubular wall. This agent was found to withstand the processing conditions associated with curing the elastomer at 288/sup 0/C and to retain a significant level of adhesive strength following hydrothermal testing in a synthetic brine at 260/sup 0/C for a period of 166 hours. Bonding tests were conducted on specimens of mild carbon steel and several alloys including Hastelloy C-276. An objective of the program was to field test the lined section of pipe mentioned above at a geothermal facility in the Imperial Valley. Though a test was conducted, problems encountered during the lining operation precluded an encouraging outcome. The results of the field demonstration were inconclusive. 6 refs., 13 figs., 13 tabs« less

  19. Comparative three-dimensional analysis of initial biofilm formation on three orthodontic bracket materials.

    PubMed

    Dittmer, Marc Philipp; Hellemann, Carolina Fuchslocher; Grade, Sebastian; Heuer, Wieland; Stiesch, Meike; Schwestka-Polly, Rainer; Demling, Anton Phillip

    2015-04-10

    The purpose of the present study was to investigate and compare early biofilm formation on biomaterials, which are being used in contemporary fixed orthodontic treatment. This study comprised 10 healthy volunteers (5 females and 5 males) with a mean age of 27.3 +-3.7 years. Three slabs of different orthodontic materials (stainless steel, gold and ceramic) were placed in randomized order on a splint in the mandibular molar region. Splints were inserted intraorally for 48 h. Then the slabs were removed from the splints and the biofilms were stained with a two color fluorescence assay for bacterial viability (LIVE/DEAD BacLight-Bacterial Viability Kit 7012, Invitrogen, Mount Waverley, Australia). The quantitative biofilm formation was analyzed by using confocal laser scanning microscopy (CLSM). The biofilm coverage was 32.7 ± 37.7% on stainless steel surfaces, 59.5 ± 40.0% on gold surfaces and 56.8 ± 43.6% on ceramic surfaces. Statistical analysis showed significant differences in biofilm coverage between the tested materials (p=0.033). The Wilcoxon test demonstrated significantly lower biofilm coverage on steel compared to gold (p=0.011). Biofilm height on stainless steel surfaces was 4.0 ± 7.3 μm, on gold surfaces 6.0 ± 6.6 μm and on ceramic 6.5 ± 6.0 μm. The Friedman test revealed no significant differences between the tested materials (p=0.150). Pairwise comparison demonstrated significant differences between stainless steel and gold (p=0.047). Our results indicate that initial biofilm formation seemed to be less on stainless steel surfaces compared with other traditional materials in a short-term observation. Future studies should examine whether there is a difference in long-term biofilm accumulation between stainless steel, gold and ceramic brackets.

  20. Influence of airborne-particle abrasion on mechanical properties and bond strength of carbon/epoxy and glass/bis-GMA fiber-reinforced resin posts.

    PubMed

    Soares, Carlos Jose; Santana, Fernanda Ribeiro; Pereira, Janaina Carla; Araujo, Tatiana Santos; Menezes, Murilo Souza

    2008-06-01

    Controversy exists concerning the use of fiber-reinforced posts to improve bond strength to resin cement because some precementation treatments can compromise the mechanical properties of the posts. The purpose of this study was to analyze the influence of airborne-particle abrasion on the mechanical properties and microtensile bond strength (MTBS) of carbon/epoxy and glass/bis-GMA fiber-reinforced resin posts. Flexural strength (delta(f)), flexural modulus (E(f)), and stiffness (S) were assessed using a 3-point bending test for glass fiber-reinforced and carbon fiber-reinforced resin posts submitted to airborne-particle abrasion (AB) with 50-microm Al(2)O(3), and for posts without any surface treatment (controls) (n=10). Forty glass fiber (GF) and 40 carbon fiber (CF) posts were submitted to 1 of 4 surface treatments (n=10) prior to MTBS testing: silane (S); silane and adhesive (SA); airborne-particle abrasion with 50-microm Al(2)O(3) and silane (ABS); airborne-particle abrasion, silane, and adhesive (ABSA). Two composite resin restorations (Filtek Z250) with rounded depressions in the lateral face were bilaterally fixed to the post with resin cement (RelyX ARC). Next, the specimen was sectioned with a precision saw running perpendicular to the bonded surface to obtain 10 bonded beam specimens with a cross-sectional area of 1 mm(2). Each beam specimen was tested in a mechanical testing machine (EMIC 2,000 DL), under stress, at a crosshead speed of 0.5 mm/min until failure. Data were analyzed by 2-way ANOVA followed by Tukey HSD test (alpha=.05). Failure patterns of tested specimens were analyzed using scanning electron microscopy (SEM). The 3-point bending test demonstrated significant differences among groups only for the post type factor for flexural strength, flexural modulus, and stiffness. The carbon fiber posts exhibited significantly higher mean flexural strength (P=.001), flexural modulus (P=.003), and stiffness (P=.001) values when compared with glass fiber posts, irrespective of surface treatment. An alteration in the superficial structure of the posts could be observed by SEM after airborne-particle abrasion. MTBS testing showed no significant effect for the surface treatment type; however, significant effects for post system factor and for interaction between the 2 factors were observed. For the carbon fiber post, the ABSA surface treatment resulted in values significantly lower than the S surface treatment. SEM analysis of MTBS-tested specimens demonstrated adhesive and cohesive failures. Airborne-particle abrasion did not influence the mechanical properties of the post; however, it produced undesirable surface changes, which could reduce the bond strength to resin cement. For the surface treatments studied, if silane is applied, the adhesive system and airborne-particle abrasion are not necessary.

  1. Parental knowledge and metabolic control of children and young adults with type 1 diabetes

    PubMed Central

    Mysliwiec, Malgorzata; Adamkiewicz-Drozynska, Elzbieta

    2016-01-01

    Introduction The authors aimed to answer the following questions: 1) What level of knowledge of type 1 diabetes do the parents of children and young adults with this disease have? 2) Will this level of knowledge increase after 1 year of observation? 3) Does improving the knowledge of young adults and their parents result in better metabolic control of the patients? Material and methods This study included 227 patients between the ages of 5 and 20 years with type 1 diabetes. The research was conducted from March 2009 to June 2011. The following two time points were examined: the beginning of the study (test 1a) and one year later (test 1b). The knowledge levels of the patients and parents were obtained using a survey and a knowledge test. Results Comparison of the results from the two study time points showed that the respondents had a significantly higher level of knowledge after 1 year (p = 0.001). The comparison of glycated hemoglobin levels between the two time points in patients with type 1 diabetes revealed that the levels were significantly higher at test 1b compared to test 1a (p = 0.0005). Conclusions The parents of children and young adults with type 1 diabetes demonstrate a satisfactory level of theoretical knowledge of therapeutic conduct and self-monitoring principles. The test 1b results demonstrated a higher level of theoretical knowledge in all respondents and poorer metabolic control. Poorer metabolic control in some patients suggests that metabolic control in type 1 diabetes depends on factors other than education. Further research is necessary to determine these additional factors. PMID:29379532

  2. Evaluation of the Thermo Scientific SureTect Listeria species assay. AOAC Performance Tested Method 071304.

    PubMed

    Cloke, Jonathan; Evans, Katharine; Crabtree, David; Hughes, Annette; Simpson, Helen; Holopainen, Jani; Wickstrand, Nina; Kauppinen, Mikko; Leon-Velarde, Carlos; Larson, Nathan; Dave, Keron

    2014-01-01

    The Thermo Scientific SureTect Listeria species Assay is a new real-time PCR assay for the detection of all species of Listeria in food and environmental samples. This validation study was conducted using the AOAC Research Institute (RI) Performance Tested Methods program to validate the SureTect Listeria species Assay in comparison to the reference method detailed in International Organization for Standardization 11290-1:1996 including amendment 1:2004 in a variety of foods plus plastic and stainless steel. The food matrixes validated were smoked salmon, processed cheese, fresh bagged spinach, cantaloupe, cooked prawns, cooked sliced turkey meat, cooked sliced ham, salami, pork frankfurters, and raw ground beef. All matrixes were tested by Thermo Fisher Scientific, Microbiology Division, Basingstoke, UK. In addition, three matrixes (pork frankfurters, fresh bagged spinach, and stainless steel surface samples) were analyzed independently as part of the AOAC-RI-controlled independent laboratory study by the University ofGuelph, Canada. Using probability of detection statistical analysis, a significant difference in favour of the SureTect assay was demonstrated between the SureTect and reference method for high level spiked samples of pork frankfurters, smoked salmon, cooked prawns, stainless steel, and low-spiked samples of salami. For all other matrixes, no significant difference was seen between the two methods during the study. Inclusivity testing was conducted with 68 different isolates of Listeria species, all of which were detected by the SureTect Listeria species Assay. None of the 33 exclusivity isolates were detected by the SureTect Listeria species Assay. Ruggedness testing was conducted to evaluate the performance of the assay with specific method deviations outside of the recommended parameters open to variation, which demonstrated that the assay gave reliable performance. Accelerated stability testing was additionally conducted, validating the assay shelf life.

  3. Development and testing of an implementation strategy for a complex housing intervention: protocol for a mixed methods study.

    PubMed

    Watson, Dennis P; Young, Jeani; Ahonen, Emily; Xu, Huiping; Henderson, Macey; Shuman, Valery; Tolliver, Randi

    2014-10-17

    There is currently a lack of scientifically designed and tested implementation strategies. Such strategies are particularly important for highly complex interventions that require coordination between multiple parts to be successful. This paper presents a protocol for the development and testing of an implementation strategy for a complex intervention known as the Housing First model (HFM). Housing First is an evidence-based practice for chronically homeless individuals demonstrated to significantly improve a number of outcomes. Drawing on practices demonstrated to be useful in implementation and e-learning theory, our team is currently adapting a face-to-face implementation strategy so that it can be delivered over a distance. Research activities will be divided between Chicago and Central Indiana, two areas with significantly different barriers to HFM implementation. Ten housing providers (five from Chicago and five from Indiana) will be recruited to conduct an alpha test of each of four e-learning modules as they are developed. Providers will be requested to keep a detailed log of their experience completing the modules and participate in one of two focus groups. After refining the modules based on alpha test results, we will test the strategy among a sample of four housing organizations (two from Chicago and two from Indiana). We will collect and analyze both qualitative and quantitative data from administration and staff. Measures of interest include causal factors affecting implementation, training outcomes, and implementation outcomes. This project is an important first step in the development of an evidence-based implementation strategy to increase scalability and impact of the HFM. The project also has strong potential to increase limited scientific knowledge regarding implementation strategies in general.

  4. Development of a BALB/c 3T3 neutral red uptake cytotoxicity test using a mainstream cigarette smoke exposure system

    PubMed Central

    2014-01-01

    Background Tobacco smoke toxicity has traditionally been assessed using the particulate fraction under submerged culture conditions which omits the vapour phase elements from any subsequent analysis. Therefore, methodologies that assess the full interactions and complexities of tobacco smoke are required. Here we describe the adaption of a modified BALB/c 3T3 neutral red uptake (NRU) cytotoxicity test methodology, which is based on the Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM) protocol for in vitro acute toxicity testing. The methodology described takes into account the synergies of both the particulate and vapour phase of tobacco smoke. This is of particular importance as both phases have been independently shown to induce in vitro cellular cytotoxicity. Findings The findings from this study indicate that mainstream tobacco smoke and the gas vapour phase (GVP), generated using the Vitrocell® VC 10 smoke exposure system, have distinct and significantly different toxicity profiles. Within the system tested, mainstream tobacco smoke produced a dilution IC50 (dilution (L/min) at which 50% cytotoxicity is observed) of 6.02 L/min, whereas the GVP produced a dilution IC50 of 3.20 L/min. In addition, we also demonstrated significant dose-for-dose differences between mainstream cigarette smoke and the GVP fraction (P < 0.05). This demonstrates the importance of testing the entire tobacco smoke aerosol and not just the particulate fraction, as has been the historical preference. Conclusions We have adapted the NRU methodology based on the ICCVAM protocol to capture the full interactions and complexities of tobacco smoke. This methodology could also be used to assess the performance of traditional cigarettes, blend and filter technologies, tobacco smoke fractions and individual test aerosols. PMID:24935030

  5. Outcome of Lateral Transfer of the FHL or FDL for Concomitant Peroneal Tendon Tears.

    PubMed

    Seybold, Jeffrey D; Campbell, John T; Jeng, Clifford L; Short, Kelly W; Myerson, Mark S

    2016-06-01

    Concomitant tears of the peroneus longus and brevis tendons are rare injuries, with literature limited to case reports and small patient series. Only 1 recent study directly compared the results of single-stage lateral deep flexor transfer, and no previous series objectively evaluated power and balance following transfer. The purpose of this study was to evaluate clinical outcomes, patient satisfaction, and objective power and balance data following single-stage flexor hallucis longus (FHL) and flexor digitorum longus (FDL) tendon transfers for treatment of concomitant peroneus longus and brevis tears. Over an 8-year period (2005-2012), 9 patients underwent lateral transfer of the FHL or FDL tendon for treatment of concomitant peroneus longus and brevis tears. All but 1 patient underwent additional procedures to address hindfoot malalignment or other contributing deformity at the time of surgery. Mean age was 56.9 years, and average body mass index was 27.9. Lateral transfer of the FHL was performed in 5 patients, and FDL transfer performed in 4 with mean follow-up 35.7 months (range: 11-94). Eight of 9 patients completed SF-12 and Foot Function Index (FFI) scores, and 7 returned for range of motion (ROM) and manual strength testing of the involved and normal extremities. These 7 patients also completed force plate balance tests, in addition to peak force and power testing on a PrimusRS machine with a certified physical therapist. All patients were satisfied with the results of the procedure. Mean SF-12 physical and mental scores were 32 and 55, respectively; mean FFI total score was 56.7. No postoperative infections were noted. Two patients continued to utilize orthotics or braces, and 2 patients reported occasional pain with weightbearing activity. Three patients noted mild paresthesias in the distribution of the sural nerve and 2 demonstrated tibial neuritis. All patients demonstrated 4/5 eversion strength in the involved extremity. Average loss of inversion and eversion ROM were 24.7% and 27.2% of normal, respectively. Mean postoperative eversion peak force and power were decreased greater than 55% relative to the normal extremity. Patients demonstrated nearly 50% increases in both center-of-pressure tracing length and velocity during balance testing. There were no statistically significant differences between the FHL and FDL transfer groups with regards to clinical examination or objective power and balance tests. The FHL and FDL tendons were both successful options for lateral transfer in cases of concomitant peroneus longus and brevis tears. Objective measurements of strength and balance demonstrated significant deficits in the operative extremity, even years following the procedure. These differences, however, did not appear to alter or inhibit patient activity levels or high satisfaction rates with the procedure. Although anatomic studies have demonstrated benefits of FHL transfer over the FDL tendon, further studies with increased patient numbers are needed to determine if these differences are clinically significant. Level IV, retrospective case series. © The Author(s) 2016.

  6. Fluoride release, recharge and mechanical property stability of various fluoride-containing resin composites.

    PubMed

    Naoum, S; Ellakwa, A; Martin, F; Swain, M

    2011-01-01

    To determine the fluoride release and recharge of three fluoride-containing resin composites when aged in deionized water (pH 6.5) and lactic acid (pH 4.0) and to assess mechanical properties of these composites following aging. Three fluoride-containing resin composites were analyzed in this study; a new giomer material named Beautifil II, Gradia Direct X, and Tetric EvoCeram. A glass ionomer cement, Fuji IX Extra, was also analyzed for comparison. Specimens were fabricated for two test groups: group 1 included 10 disc specimens initially aged 43 days in deionized water (five specimens) and lactic acid (five specimens). The fluoride release from these specimens was measured using a fluoride-specific electrode on nine specific test days during the aging period. Following 49 days of aging, each specimen was recharged in 5000 ppm neutral sodium fluoride solution for 5 minutes. Specimen recharge was then repeated on a weekly basis for 3 weeks. The subsequent fluoride rerelease was measured at 1, 3, and 7 days after each recharge episode. Group 2 included six disc specimens aged for 3 months in deionized water (three specimens) and lactic acid (three specimens). The hardness and elastic modulus of each specimen was measured using nano-indentation at intervals of 24 hours, 1 month, and 3 months after fabrication. Two-way factorial analysis of variance (ANOVA) and post-hoc (Tukey) testing was used to assess the influence of storage media (two levels) and composite type (three levels) on the fluoride release, fluoride rerelease, hardness, and elastic modulus of the assessed materials. The level of significance was set at p=0.05. All three composites demonstrated fluoride release and recharge when aged in both deionized water and lactic acid. The cumulative fluoride released from Beautifil II into both media was substantially greater than the fluoride released from Gradia Direct X and Tetric EvoCeram after 43 days aging and was significantly (p<0.05, ANOVA, Tukey test) greater during several analysis periods. Beautifil II demonstrated the greatest recharge ability of the three composites over the 3-week recharge period in both media. Fuji IX Extra demonstrated a significantly (p<0.05) greater fluoride release and recharge compared with the three resin composites. The elastic modulus and hardness of the three composites did not decrease significantly (p<0.05) with fluoride release or fluid uptake over the 3-month aging period, in either media. The three composites in the present study demonstrated fluoride release (Beautiful II > Gradia Direct X > Tetric EvoCeram) and fluoride recharge (Beautiful II > Gradia Direct X > Tetric EvoCeram). This capability raises the possibility of fluoride-containing composites exhibiting a lower incidence of recurrent caries than non fluoride–containing composites. The mechanical properties of each composite did not diminish with aging and fluoride release over the testing period.

  7. Neural Correlates of Individual Differences in Infant Visual Attention and Recognition Memory

    PubMed Central

    Reynolds, Greg D.; Guy, Maggie W.; Zhang, Dantong

    2010-01-01

    Past studies have identified individual differences in infant visual attention based upon peak look duration during initial exposure to a stimulus. Colombo and colleagues (e.g., Colombo & Mitchell, 1990) found that infants that demonstrate brief visual fixations (i.e., short lookers) during familiarization are more likely to demonstrate evidence of recognition memory during subsequent stimulus exposure than infants that demonstrate long visual fixations (i.e., long lookers). The current study utilized event-related potentials to examine possible neural mechanisms associated with individual differences in visual attention and recognition memory for 6- and 7.5-month-old infants. Short- and long-looking infants viewed images of familiar and novel objects during ERP testing. There was a stimulus type by looker type interaction at temporal and frontal electrodes on the late slow wave (LSW). Short lookers demonstrated a LSW that was significantly greater in amplitude in response to novel stimulus presentations. No significant differences in LSW amplitude were found based on stimulus type for long lookers. These results indicate deeper processing and recognition memory of the familiar stimulus for short lookers. PMID:21666833

  8. A comprehensive laboratory-based program for classification of variants of uncertain significance in hereditary cancer genes.

    PubMed

    Eggington, J M; Bowles, K R; Moyes, K; Manley, S; Esterling, L; Sizemore, S; Rosenthal, E; Theisen, A; Saam, J; Arnell, C; Pruss, D; Bennett, J; Burbidge, L A; Roa, B; Wenstrup, R J

    2014-09-01

    Genetic testing has the potential to guide the prevention and treatment of disease in a variety of settings, and recent technical advances have greatly increased our ability to acquire large amounts of genetic data. The interpretation of this data remains challenging, as the clinical significance of genetic variation detected in the laboratory is not always clear. Although regulatory agencies and professional societies provide some guidance regarding the classification, reporting, and long-term follow-up of variants, few protocols for the implementation of these guidelines have been described. Because the primary aim of clinical testing is to provide results to inform medical management, a variant classification program that offers timely, accurate, confident and cost-effective interpretation of variants should be an integral component of the laboratory process. Here we describe the components of our laboratory's current variant classification program (VCP), based on 20 years of experience and over one million samples tested, using the BRCA1/2 genes as a model. Our VCP has lowered the percentage of tests in which one or more BRCA1/2 variants of uncertain significance (VUSs) are detected to 2.1% in the absence of a pathogenic mutation, demonstrating how the coordinated application of resources toward classification and reclassification significantly impacts the clinical utility of testing. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Immobilization and phytotoxicity of chromium in contaminated soil remediated by CMC-stabilized nZVI.

    PubMed

    Wang, Yu; Fang, Zhanqiang; Kang, Yuan; Tsang, Eric Pokeung

    2014-06-30

    The toxic effect of Cr(VI)-contaminated soil remediated by sodium carboxymethyl cellulose stabilized nanoscale zero-valent iron (CMC-stabilized nZVI) was assessed through in vitro toxicity and phytotoxicity tests. In vitro tests showed that 0.09 g L(-1) of Fe(0) nanoparticles (soil-to-solution ratio was 1 g:5 mL) significantly reduced the toxicity characteristic leaching procedure (TCLP) leachability and physiological based extraction test (PBET) bioaccessibility of Cr by 82% and 58%, respectively. Sequential extraction procedures (SEP) revealed that exchangeable (EX) Cr was completely converted to Fe-Mn oxides (OX) and organic matter (OM). Accordingly, phytotoxicity tests indicated that after 72-h remediation, Cr uptakes by edible rape and Chinese cabbage were suppressed by 61% and 36%, respectively. Moreover, no significant increase in Cr uptake was observed for either species after a 1-month static period for the amended soil. Regarding Fe absorption, germination and seedling growth, both plant species were significantly affected by CMC-nZVI-exposed soils. However, similar phytotoxicity tests conducted after 1 month showed an improvement in cultivation for both plants. Overall, this study demonstrated that CMC-nZVI could significantly enhance Cr immobilization, which reduced its leachability, bioavailability and bioaccumulation by plants. From a detoxification perspective, such remediation is technologically feasible and shows great potential in field applications. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. A systematic review to evaluate the effectiveness of carnitine supplementation in improving walking performance among individuals with intermittent claudication.

    PubMed

    Delaney, Christopher L; Spark, J Ian; Thomas, Jolene; Wong, Yew Toh; Chan, Lok Tsung; Miller, Michelle D

    2013-07-01

    To evaluate the evidence for the use of carnitine supplementation in improving walking performance among individuals with intermittent claudication. Systematic review. An electronic search of the literature was performed using MEDLINE (PubMed), Scopus, Cochrane Central Register of Controlled Trials and The Cochrane Library from inception through to November 2012. Search terms included peripheral arterial disease, intermittent claudication and carnitine. Reference lists of review articles and primary studies were also examined. Full reports of published experimental studies including randomized controlled trials and pre-test/post-test trials were selected for inclusion. A quality assessment was undertaken according to the Jadad scale. A total of 40 articles were retrieved, of which 23 did not meet the inclusion criteria. The 17 included articles reported on a total of 18 experimental studies of carnitine supplementation (5 pre-test/post-test; 8 parallel RCT; 5 cross-over RCT) for improving walking performance in adults with intermittent claudication. For pre-test/post-test studies, 300-2000 mg propionyl-L-carnitine (PLC) was administered orally or intravenously for a maximum of 90 days (7-42 participants) with statistically significant improvements of between 74 m and 157 m in pain free walking distance and between 71 m and 135 m in maximal walking distance across 3 out of 5 studies. Similarly, PLC (600 mg-3000 mg) was administered orally in 7 out of 8 parallel RCTs (22-485 participants), the longest duration being 12 months. All but one of the smallest trials demonstrated statistically significant improvements in walking performance between 31 and 54 m greater than placebo for pain free walking distance and between 9 and 86 m greater than placebo for maximal walking distance. A double-blind parallel RCT of cilostazol plus 2000 mg oral L-carnitine or placebo for 180 days (145 participants) did not demonstrate any significant improvement in walking performance. Of 5 cross-over RCTs (8-20 participants), 4 demonstrated significant improvements in walking performance following administration of 300-6000 mg L-carnitine or PLC. Compared to placebo, pain free walking distance and maximal walking distance improved by 23-132 m and 104 m respectively following carnitine intervention. Most trials demonstrated a small or modest improvement in walking performance with administration of PLC or L-carnitine. These findings were largely independent of level or quality of evidence, while there was some evidence that intravenous administration was more effective than oral administration and those with severe claudication may achieve greater benefits than those with moderate claudication. Routine carnitine supplementation in the form of PLC may therefore be a useful adjunct therapy for management of intermittent claudication. Further research is warranted to determine the optimal form, duration, dose and safety of carnitine supplementation across the spectrum of peripheral arterial disease severity and its effect with concurrent supervised exercise programs and best medical therapy. These studies should be supplemented with cost effectiveness studies to ensure that the return on the investment is acceptable. Crown Copyright © 2013. Published by Elsevier Ireland Ltd. All rights reserved.

  11. The effect of clobazam and lorazepam on the psychomotor performance of anxious patients

    PubMed Central

    Oblowitz, H.; Robins, A. H.

    1983-01-01

    1 Psychomotor performance and anxiety were measured in 70 anxious outpatients in a randomized double-blind, placebo-controlled trial comparing the 1,5-benzodiazepine clobazam (10 mg twice a day) to lorazepam (1 mg twice a day). Carefully selected tests were administered pre-treatment and at 2 and 9 days after treatment. Compliance was checked by blood assays. 2 All three treatment groups (clobazam, lorazepam and placebo) showed a significant improvement in anxiety over the course of the trial. There were no significant differences between the groups in terms of anxiety reduction. 3 All three groups improved over the course of the trial in choice reaction time, digit symbol substitution test, Purdue pegboard test (both hands) and in the Inglis paired-associate learning test: there were no significant differences between the groups with regard to these tests. There was no change in critical flicker fusion threshold over the trial period in any of the three groups. 4 The placebo and clobazam groups showed a significant improvement in two of the Purdue pegboard tests (preferred hand and assembly) from pre-treatment to 2 days but no further improvement at 9 days. The lorazepam group, however, showed no improvement in these two tests from pre-treatment to 2 days; a significant improvement only emerged between the 2-day and 9-day assessments. This might reflect an initial, transient sedation in the lorazepam-treated patients. 5 Generally, we failed to demonstrate any consistent impairment in psychomotor performance with either clobazam or lorazepam in our anxious patients. These findings contrast with those obtained after administration of 1,4-benzodiazepines (e.g., lorazepam) to normal volunteers and they suggest that data from the latter cannot necessarily be extrapolated to anxious patients. PMID:6136292

  12. Impact of Intentional Overload on Joint Stability of Internal Implant-Abutment Connection System with Different Diameter.

    PubMed

    Lee, Ji-Hye; Lee, Won; Huh, Yoon-Hyuk; Park, Chan-Jin; Cho, Lee-Ra

    2017-09-05

    To evaluate the axial displacement of the implant-abutment assembly of different implant diameter after static and cyclic loading of overload condition. An internal conical connection system with three diameters (Ø 4.0, 4.5, and 5.0) applying identical abutment dimension and the same abutment screw was evaluated. Axial displacement of abutment and reverse torque loss of abutment screw were evaluated under static and cyclic loading conditions. Static loading test groups were subjected to vertical static loading of 250, 400, 500, 600, 700, and 800 N consecutively. Cyclic loading test groups were subjected to 500 N cyclic loading to evaluate the effect of excessive masticatory loading. After abutment screw tightening for 30 Ncm, axial displacement was measured upon 1, 3, 10, and 1,000,000 cyclic loadings of 500 N. Repeated-measure ANOVA and 2-way ANOVA were used for statistical analysis (α = 0.05). The increasing magnitude of vertical load and thinner wall thickness of implant increased axial displacement of abutment and reverse torque loss of abutment screw (p < 0.05). Implants in the Ø 5.0 diameter group demonstrated significantly low axial displacement, and reverse torque loss after static loading than Ø 4.0 and Ø 4.5 diameter groups (p < 0.05). In the cyclic loading test, all diameter groups of implant showed significant axial displacement after 1 cycle of loading of 500 N (p < 0.05). There was no significant axial displacement after 3, 10, or 1,000,000 cycles of loading (p = 0.603). Implants with Ø 5.0 diameter demonstrated significantly low axial displacement and reverse torque loss after the cyclic and static loading of overload condition. © 2017 by the American College of Prosthodontists.

  13. Do Neurocognitive SCAT3 Baseline Test Scores Differ Between Footballers (Soccer) Living With and Without Disability? A Cross-Sectional Study.

    PubMed

    Weiler, Richard; van Mechelen, Willem; Fuller, Colin; Ahmed, Osman Hassan; Verhagen, Evert

    2018-01-01

    To determine if baseline Sport Concussion Assessment Tool, third Edition (SCAT3) scores differ between athletes with and without disability. Cross-sectional comparison of preseason baseline SCAT3 scores for a range of England international footballers. Team doctors and physiotherapists supporting England football teams recorded players' SCAT 3 baseline tests from August 1, 2013 to July 31, 2014. A convenience sample of 249 England footballers, of whom 185 were players without disability (male: 119; female: 66) and 64 were players with disability (male learning disability: 17; male cerebral palsy: 28; male blind: 10; female deaf: 9). Between-group comparisons of median SCAT3 total and section scores were made using nonparametric Mann-Whitney-Wilcoxon ranked-sum test. All footballers with disability scored higher symptom severity scores compared with male players without disability. Male footballers with learning disability demonstrated no significant difference in the total number of symptoms, but recorded significantly lower scores on immediate memory and delayed recall compared with male players without disability. Male blind footballers' scored significantly higher for total concentration and delayed recall, and male footballers with cerebral palsy scored significantly higher on balance testing and immediate memory, when compared with male players without disability. Female footballers with deafness scored significantly higher for total concentration and balance testing than female footballers without disability. This study suggests that significant differences exist between SCAT3 baseline section scores for footballers with and without disability. Concussion consensus guidelines should recognize these differences and produce guidelines that are specific for the growing number of athletes living with disability.

  14. Bond strength determination of hydroxyapatite coatings on Ti-6Al-4V substrates using the LAser Shock Adhesion Test (LASAT).

    PubMed

    Guipont, Vincent; Jeandin, Michel; Bansard, Sebastien; Khor, Khiam Aik; Nivard, Mariette; Berthe, Laurent; Cuq-Lelandais, Jean-Paul; Boustie, Michel

    2010-12-15

    An adhesion test procedure applied to plasma-sprayed hydroxyapatite (HA) coatings to measure the "LASAT threshold" (LAser Shock Adhesion test) is described. The good repeatability and minimal discrepancy of the laser-driven adhesion test data were ascertained for conventional plasma sprayed HA coatings. As a further demonstration, the procedure was applied to HA coatings with diverse characteristics on the ceramic/metal interface. Different preheating and grit blasting conditions and the presence of a thick plasma-sprayed Ti sublayer or a thin TiO(2) layer prepared by oxidation were investigated through LASAT. It was assessed that a rough surface can significantly improve the coating's bond strength. However, it was also demonstrated that a thin TiO(2) layer on a smooth Ti-6Al-4V substrate can have a major influence on adhesion as well. Preheating up to 270°C just prior to the first HA spraying pass had no effect on the adhesion strength. Further development of the procedure was done to achieve an in situ LASAT with in vitro conditions applied on HA coatings. To that end, different crystalline HA contents were soaked in simulated body fluid (SBF). Beyond the demonstration of the capability of this laser-driven adhesion test devoted to HA coatings in dry or liquid environment, the present study provided empirical information on pertinent processing characteristics that could strengthen or weaken the HA/Ti-6Al-4V bond. Copyright © 2010 Wiley Periodicals, Inc.

  15. Correlations of Platooning Track Test and Wind Tunnel Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lammert, Michael P.; Kelly, Kenneth J.; Yanowitz, Janet

    In this report, the National Renewable Energy Laboratory analyzed results from multiple, independent truck platooning projects to compare and contrast track test results with wind tunnel test results conducted by Lawrence Livermore National Laboratory (LLNL). Some highlights from the report include compiled data, and results from four independent SAE J1321 full-size track test campaigns that were compared to LLNL wind tunnel testing results. All platooning scenarios tested demonstrated significant fuel savings with good correlation relative to following distances, but there are still unanswered questions and clear opportunities for system optimization. NOx emissions showed improvements from NREL tests in 2014 tomore » Auburn tests in 2015 with respect to J1321 platooning track testing of Peloton system. NREL evaluated data from Volpe's Naturalistic Study of Truck Following Behavior, which showed minimal impact of naturalistic background platooning. We found significant correlation between multiple track studies, wind tunnel tests, and computational fluid dynamics, but also showed that there is more to learn regarding close formation and longer-distance effects. We also identified potential areas for further research and development, including development of advanced aerodynamic designs optimized for platooning, measurement of platoon system performance in traffic conditions, impact of vehicle lateral offsets on platooning performance, and characterization of the national potential for platooning based on fleet operational characteristics.« less

  16. Cryogenic Propellant Long-Term Storage With Zero Boil-Off

    NASA Technical Reports Server (NTRS)

    Hedayat, Ali; Hastings, L. J.; Bryant, C.; Plachta, D. W.; Cruit, Wendy (Technical Monitor)

    2001-01-01

    Significant boil-off losses from cryogenic propellant storage systems in long-duration space mission applications result in additional propellant and larger tanks. The potential propellant mass loss reductions with the Zero Boil-off (ZBO) concept are substantial; therefore, further exploration through technology programs has been initiated within NASA. A large-scale demonstration of the ZBO concept has been devised utilizing the Marshall Space Flight Center (MSFC) Multipurpose Hydrogen Test Bed (MHTB) along with a cryo-cooler unit. The ZBO concept consists of an active cryo-cooling system integrated with traditional passive thermal insulation. The cryo-cooler is interfaced with the MHTB and spraybar recirculation/mixer system in a manner that enables thermal energy removal at a rate that equals the total tank heat leak. The liquid hydrogen (LH2) is withdrawn from the tank, passed through a heat exchanger, and then the chilled liquid is sprayed back into the tank through a spraybar. The test series will be performed over a 20-30 day period. Tests will be conducted at multiple fill levels to demonstrate concept viability and to provide benchmark data to be used in analytical model development. In this paper the test set-up and test procedures are presented.

  17. Early Flight Fission Test Facilities (EFF-TF) and Concepts That Support Near-Term Space Fission Missions

    NASA Technical Reports Server (NTRS)

    VanDyke, Melissa; Houts, Mike; Godfroy, Thomas; Martin, James

    2003-01-01

    Fission technology can enable rapid, affordable access to any point in the solar system. If fusion propulsion systems are to be developed to their full potential; however, near-term customers must be identified and initial fission systems successfully developed, launched, and utilized. Successful utilization will most likely occur if frequent, significant hardware-based milestones can be achieved throughout the program. If the system is designed to operate within established radiation damage and fuel burn up limits while simultaneously being designed to allow close simulation of heat from fission using resistance heaters, high confidence in fission system pe$ormance and lifetime can be attained through non-nuclear testing. Through demonstration of systems concepts (designed by DOE National Laboratories) in relevant environments, this philosophy has been demonstrated through hardware testing in the Early Flight Fission Test Facilities (EFF-TF) at the Marshall Space Flight Center. The EFF-TF is designed to enable very realistic non-nuclear testing of space fission systems. Ongoing research at the EFF-TF is geared towards facilitating research, development, system integration, and system utilization via cooperative efforts with DOE labs, industry, universities, and other NASA centers.

  18. Effects of Active Sting Damping on Common Research Model Data Quality

    NASA Technical Reports Server (NTRS)

    Acheson, Michael J.; Balakrishna, S.

    2011-01-01

    Recent tests using the Common Research Model (CRM) at the Langley National Transonic Facility (NTF) and the Ames 11-foot Transonic Wind Tunnel (11' TWT) produced large sets of data that have been used to examine the effects of active damping on transonic tunnel aerodynamic data quality. In particular, large statistically significant sets of repeat data demonstrate that the active damping system had no apparent effect on drag, lift and pitching moment repeatability during warm testing conditions, while simultaneously enabling aerodynamic data to be obtained post stall. A small set of cryogenic (high Reynolds number) repeat data was obtained at the NTF and again showed a negligible effect on data repeatability. However, due to a degradation of control power in the active damping system cryogenically, the ability to obtain test data post-stall was not achieved during cryogenic testing. Additionally, comparisons of data repeatability between NTF and 11-ft TWT CRM data led to further (warm) testing at the NTF which demonstrated that for a modest increase in data sampling time, a 2-3 factor improvement in drag, and pitching moment repeatability was readily achieved not related with the active damping system.

  19. Small sample mediation testing: misplaced confidence in bootstrapped confidence intervals.

    PubMed

    Koopman, Joel; Howe, Michael; Hollenbeck, John R; Sin, Hock-Peng

    2015-01-01

    Bootstrapping is an analytical tool commonly used in psychology to test the statistical significance of the indirect effect in mediation models. Bootstrapping proponents have particularly advocated for its use for samples of 20-80 cases. This advocacy has been heeded, especially in the Journal of Applied Psychology, as researchers are increasingly utilizing bootstrapping to test mediation with samples in this range. We discuss reasons to be concerned with this escalation, and in a simulation study focused specifically on this range of sample sizes, we demonstrate not only that bootstrapping has insufficient statistical power to provide a rigorous hypothesis test in most conditions but also that bootstrapping has a tendency to exhibit an inflated Type I error rate. We then extend our simulations to investigate an alternative empirical resampling method as well as a Bayesian approach and demonstrate that they exhibit comparable statistical power to bootstrapping in small samples without the associated inflated Type I error. Implications for researchers testing mediation hypotheses in small samples are presented. For researchers wishing to use these methods in their own research, we have provided R syntax in the online supplemental materials. (c) 2015 APA, all rights reserved.

  20. American Sign Language Comprehension Test: A Tool for Sign Language Researchers.

    PubMed

    Hauser, Peter C; Paludneviciene, Raylene; Riddle, Wanda; Kurz, Kim B; Emmorey, Karen; Contreras, Jessica

    2016-01-01

    The American Sign Language Comprehension Test (ASL-CT) is a 30-item multiple-choice test that measures ASL receptive skills and is administered through a website. This article describes the development and psychometric properties of the test based on a sample of 80 college students including deaf native signers, hearing native signers, deaf non-native signers, and hearing ASL students. The results revealed that the ASL-CT has good internal reliability (α = 0.834). Discriminant validity was established by demonstrating that deaf native signers performed significantly better than deaf non-native signers and hearing native signers. Concurrent validity was established by demonstrating that test results positively correlated with another measure of ASL ability (r = .715) and that hearing ASL students' performance positively correlated with the level of ASL courses they were taking (r = .726). Researchers can use the ASL-CT to characterize an individual's ASL comprehension skills, to establish a minimal skill level as an inclusion criterion for a study, to group study participants by ASL skill (e.g., proficient vs. nonproficient), or to provide a measure of ASL skill as a dependent variable. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Evaluation of nitrous oxide as a substitute for sulfur hexafluoride to reduce global warming impacts of ANSI/HPS N13.1 gaseous uniformity testing

    NASA Astrophysics Data System (ADS)

    Yu, Xiao-Ying; Barnett, J. Matthew; Amidan, Brett G.; Recknagle, Kurtis P.; Flaherty, Julia E.; Antonio, Ernest J.; Glissmeyer, John A.

    2018-03-01

    The ANSI/HPS N13.1-2011 standard requires gaseous tracer uniformity testing for sampling associated with stacks used in radioactive air emissions. Sulfur hexafluoride (SF6), a greenhouse gas with a high global warming potential, has long been the gas tracer used in such testing. To reduce the impact of gas tracer tests on the environment, nitrous oxide (N2O) was evaluated as a potential replacement to SF6. The physical evaluation included the development of a test plan to record percent coefficient of variance and the percent maximum deviation between the two gases while considering variables such as fan configuration, injection position, and flow rate. Statistical power was calculated to determine how many sample sets were needed, and computational fluid dynamic modeling was utilized to estimate overall mixing in stacks. Results show there are no significant differences between the behaviors of the two gases, and SF6 modeling corroborated N2O test results. Although, in principle, all tracer gases should behave in an identical manner for measuring mixing within a stack, the series of physical tests guided by statistics was performed to demonstrate the equivalence of N2O testing to SF6 testing in the context of stack qualification tests. The results demonstrate that N2O is a viable choice leading to a four times reduction in global warming impacts for future similar compliance driven testing.

  2. The light spot test: Measuring anxiety in mice in an automated home-cage environment.

    PubMed

    Aarts, Emmeke; Maroteaux, Gregoire; Loos, Maarten; Koopmans, Bastijn; Kovačević, Jovana; Smit, August B; Verhage, Matthijs; Sluis, Sophie van der

    2015-11-01

    Behavioral tests of animals in a controlled experimental setting provide a valuable tool to advance understanding of genotype-phenotype relations, and to study the effects of genetic and environmental manipulations. To optimally benefit from the increasing numbers of genetically engineered mice, reliable high-throughput methods for comprehensive behavioral phenotyping of mice lines have become a necessity. Here, we describe the development and validation of an anxiety test, the light spot test, that allows for unsupervised, automated, high-throughput testing of mice in a home-cage system. This automated behavioral test circumvents bias introduced by pretest handling, and enables recording both baseline behavior and the behavioral test response over a prolonged period of time. We demonstrate that the light spot test induces a behavioral response in C57BL/6J mice. This behavior reverts to baseline when the aversive stimulus is switched off, and is blunted by treatment with the anxiolytic drug Diazepam, demonstrating predictive validity of the assay, and indicating that the observed behavioral response has a significant anxiety component. Also, we investigated the effectiveness of the light spot test as part of sequential testing for different behavioral aspects in the home-cage. Two learning tests, administered prior to the light spot test, affected the light spot test parameters. The light spot test is a novel, automated assay for anxiety-related high-throughput testing of mice in an automated home-cage environment, allowing for both comprehensive behavioral phenotyping of mice, and rapid screening of pharmacological compounds. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Spherical primary optical telescope (SPOT) segments

    NASA Astrophysics Data System (ADS)

    Hall, Christopher; Hagopian, John; DeMarco, Michael

    2012-09-01

    The spherical primary optical telescope (SPOT) project is an internal research and development program at NASA Goddard Space Flight Center. The goals of the program are to develop a robust and cost effective way to manufacture spherical mirror segments and demonstrate a new wavefront sensing approach for continuous phasing across the segmented primary. This paper focuses on the fabrication of the mirror segments. Significant cost savings were achieved through the design, since it allowed the mirror segments to be cast rather than machined from a glass blank. Casting was followed by conventional figuring at Goddard Space Flight Center. After polishing, the mirror segments were mounted to their composite assemblies. QED Technologies used magnetorheological finishing (MRF®) for the final figuring. The MRF process polished the mirrors while they were mounted to their composite assemblies. Each assembly included several magnetic invar plugs that extended to within an inch of the face of the mirror. As part of this project, the interaction between the MRF magnetic field and invar plugs was evaluated. By properly selecting the polishing conditions, MRF was able to significantly improve the figure of the mounted segments. The final MRF figuring demonstrates that mirrors, in the mounted configuration, can be polished and tested to specification. There are significant process capability advantes due to polishing and testing the optics in their final, end-use assembled state.

  4. Evidence that genetic variation in the oxytocin receptor (OXTR) gene influences social cognition in ADHD.

    PubMed

    Park, J; Willmott, M; Vetuz, G; Toye, C; Kirley, A; Hawi, Z; Brookes, K J; Gill, M; Kent, L

    2010-05-30

    Some children with ADHD also have social and communication difficulties similar to those seen in children with autistic spectrum disorders and this may be due to shared genetic liability. As the oxytocin receptor (OXTR) gene has been implicated in social cognition and autistic spectrum disorders, this study investigated whether OXTR polymorphisms previously implicated in autism were associated with ADHD and whether they influenced OXTR mRNA expression in 27 normal human amygdala brain samples. The family-based association sample consisted of 450 DSM-IV diagnosed ADHD probands and their parents. Although there was no association with the ADHD phenotype, an association with social cognitive impairments in a subset of the ADHD probands (N=112) was found for SNP rs53576 (F=5.24, p=0.007) with post-hoc tests demonstrating that the AA genotype was associated with better social ability compared to the AG genotype. Additionally, significant association was also found for rs13316193 (F=3.09, p=0.05) with post-hoc tests demonstrating that the CC genotype was significantly associated with poorer social ability than the TT genotype. No significant association between genotype and OXTR mRNA expression was found. This study supports previous evidence that the OXTR gene is implicated in social cognition. Copyright 2010 Elsevier Inc. All rights reserved.

  5. Detection of circulating tumour cells in peripheral blood of patients with malignant pleural mesothelioma.

    PubMed

    Raphael, Jacques; Massard, Christophe; Gong, Inna Y; Farace, Françoise; Margery, Jacques; Billiot, Fanny; Hollebecque, Antoine; Besse, Benjamin; Soria, Jean-Charles; Planchard, David

    2015-01-01

    The independent prognostic value of Circulating Tumour Cells (CTC) level has been demonstrated in several solid tumours. There is currently few data on Malignant Pleural Mesothelioma (MPM) and CTC. We investigated whether the presence of CTC was correlated with prognosis factors and treatment efficacy. MPM patients (pts) were enrolled in a prospective monocentric study. CTC detection was made using the "CellSearch" assay. The correlation between the presence of CTC and worse prognosis factors was assessed using the X(2) test. Comparison of Overall Survival (OS) and Progression Free Survival (PFS) according to CTC detection was performed using the log-rank test. Twenty-seven MPM pts with a median follow-up of 4.2 months were included. CTC were detected in 44% of pts with a median level of 1.5. No significant correlation was observed between the presence of CTC and worse prognosis factors. Moreover, CTC detection was not a significant predictor of OS or PFS (p=0.155 and p=0.32 respectively). CTC were detected in a small cohort of MPM patients. We couldn't demonstrate a significant prognostic value or a difference in OS/PFS between CTC levels. Further analyses, validation studies and detection techniques are needed to establish their real clinical value in MPM.

  6. Experimental Evaluation of the Heat Sink Effect in Hepatic Microwave Ablation.

    PubMed

    Ringe, Kristina I; Lutat, Carolin; Rieder, Christian; Schenk, Andrea; Wacker, Frank; Raatschen, Hans-Juergen

    2015-01-01

    To demonstrate and quantify the heat sink effect in hepatic microwave ablation (MWA) in a standardized ex vivo model, and to analyze the influence of vessel distance and blood flow on lesion volume and shape. 108 ex vivo MWA procedures were performed in freshly harvested pig livers. Antennas were inserted parallel to non-perfused and perfused (700,1400 ml/min) glass tubes (diameter 5mm) at different distances (10, 15, 20mm). Ablation zones (radius, area) were analyzed and compared (Kruskal-Wallis Test, Dunn's multiple comparison Test). Temperature changes adjacent to the tubes were measured throughout the ablation cycle. Maximum temperature decreased significantly with increasing flow and distance (p<0.05). Compared to non-perfused tubes, ablation zones were significantly deformed by perfused tubes within 15 mm distance to the antenna (p<0.05). At a flow rate of 700 ml/min ablation zone radius was reduced to 37.2% and 80.1% at 10 and 15 mm tube distance, respectively; ablation zone area was reduced to 50.5% and 89.7%, respectively. Significant changes of ablation zones were demonstrated in a pig liver model. Considerable heat sink effect was observed within a diameter of 15 mm around simulated vessels, dependent on flow rate. This has to be taken into account when ablating liver lesions close to vessels.

  7. Seizure entrainment with polarizing low frequency electric fields in a chronic animal epilepsy model

    PubMed Central

    Sunderam, Sridhar; Chernyy, Nick; Peixoto, Nathalia; Mason, Jonathan P.; Weinstein, Steven L.; Schiff, Steven J.; Gluckman, Bruce J.

    2009-01-01

    Neural activity can be modulated by applying a polarizing low frequency (≪ 100 Hz) electric field (PLEF). Unlike conventional pulsed stimulation, PLEF stimulation has a graded, modulatory effect on neuronal excitability, and permits the simultaneous recording of neuronal activity during stimulation suitable for continuous feedback control. We tested a prototype system that allows for simultaneous PLEF stimulation with minimal recording artifact in a chronic tetanus toxin animal model (rat) of hippocampal epilepsy with spontaneous seizures. Depth electrode local field potentials recorded during seizures revealed a characteristic pattern of field postsynaptic potentials (fPSPs). Sinusoidal voltage-controlled PLEF stimulation (0.5–25 Hz) was applied in open-loop cycles radially across the CA3 of ventral hippocampus. For stimulated seizures, fPSPs were transiently entrained with the PLEF waveform. Statistical significance of entrainment was assessed with Thomson’s harmonic F-test, with 45/132 stimulated seizures in 4 animals individually demonstrating significant entrainment (p < 0.04). Significant entrainment for multiple presentations at the same frequency (p < 0.01) was observed in 3 of 4 animals in 42/64 stimulated seizures. This is the first demonstration in chronically implanted freely behaving animals of PLEF modulation of neural activity with simultaneous recording. PMID:19602730

  8. [Specificity and sensitivity of immunological diagnosis of congenital neonatal syphilis by the 19S(IgM)-FTA-ABS test (author's transl)].

    PubMed

    Müller, F; Sinzig, G

    1982-07-01

    Reports on the significance in the demonstration of IgM class antibodies in congenital syphilis are contradictory. The reason for discrepant observations are of technical or biological source. In order to explain the several uncertainties, serum samples from 1031 newborns and infants of syphilitic mothers were investigated quantitatively with the IgM-FTA-ABS, the 19S (IgM)-FTA-ABS and cardiolipin CF test. If serum specimens of the mothers were available they were investigated in the same tests for treponema-specific 19S(IgM) class and antilipoidal antibodies. In the evaluation of the results, the history of infection and treatment of the mothers as well as clinical observations in the infants were considered. In 26 children a congenital acquired syphilis was strongly indicated by demonstration of treponema-specific 19S(IgM) class antibodies by the 19S(IgM)-FTA-ABS-Test and tae good agreement with the history of untreated mothers. In another 1005 infants a congenital infection by T. pallidum could be excluded by the non-reactive 19S(IgM)-FTA-ABS as well as clinical observations. Furthermore, immunological findings of three children who had acquired syphilis after birth are demonstrated before and after specific treatment. It could be shown that the 19S(IgM)-FTA-ABS is much more infaillable than the IgM-FTA-ABS as far as technical and biological uncertainties are concerned. Considering all possible errors and the results of re-investigations of IgM non-reactive infants of syphilitic mothers (up to one year after birth) it is demonstrated that congenital syphilis can be differentiated from passively transmitted 7S(IgG) class antibodies (of the mother) or 19S(IgM) class anti-antibodies (of the child) with a significance of about 99%. It is finally concluded that serological diagnosis of congenital syphilis should be started in the pregnant women. By making the diagnosis in pregnancy followed by adequate treatment, irreversible damages as well as so-called serological scars can be avoided in the children.

  9. Sublingual microcirculatory blood flow and vessel density in Sherpas at high altitude

    PubMed Central

    Coppel, Jonny; Court, Jo; van der Kaaij, Jildou; Vercueil, Andre; Feelisch, Martin; Levett, Denny; Mythen, Monty; Grocott, Michael P.; Martin, Daniel

    2017-01-01

    Anecdotal reports suggest that Sherpa highlanders demonstrate extraordinary tolerance to hypoxia at high altitude, despite exhibiting lower arterial oxygen content than acclimatized lowlanders. This study tested the hypothesis that Sherpas exposed to hypobaric hypoxia on ascent to 5,300 m develop increased microcirculatory blood flow as a means of maintaining tissue oxygen delivery. Incident dark-field imaging was used to obtain images of the sublingual microcirculation from 64 Sherpas and 69 lowlanders. Serial measurements were obtained from participants undertaking an ascent from baseline testing (35 m or 1,300 m) to Everest base camp (5,300 m) and following subsequent descent in Kathmandu (1,300 m). Microcirculatory flow index and heterogeneity index were used to provide indexes of microcirculatory flow, while capillary density was assessed using small vessel density. Sherpas demonstrated significantly greater microcirculatory blood flow at Everest base camp, but not at baseline testing or on return in Kathmandu, than lowlanders. Additionally, blood flow exhibited greater homogeneity at 5,300 and 1,300 m (descent) in Sherpas than lowlanders. Sublingual small vessel density was not different between the two cohorts at baseline testing or at 1,300 m; however, at 5,300 m, capillary density was up to 30% greater in Sherpas. These data suggest that Sherpas can maintain a significantly greater microcirculatory flow per unit time and flow per unit volume of tissue at high altitude than lowlanders. These findings support the notion that peripheral vascular factors at the microcirculatory level may be important in the process of adaptation to hypoxia. NEW & NOTEWORTHY Sherpa highlanders demonstrate extraordinary tolerance to hypoxia at high altitude, yet the physiological mechanisms underlying this tolerance remain unknown. In our prospective study, conducted on healthy volunteers ascending to Everest base camp (5,300 m), we demonstrated that Sherpas have a higher sublingual microcirculatory blood flow and greater capillary density at high altitude than lowlanders. These findings support the notion that the peripheral microcirculation plays a key role in the process of long-term adaptation to hypoxia. PMID:28126908

  10. Thermal Modeling in Support of the Edison Demonstration of Smallsat Networks Project

    NASA Technical Reports Server (NTRS)

    Coker, Robert

    2013-01-01

    NASA's Edison program is intending to launch a swarm of at least 8 small satellites in 2013. This swarm of 1.5U Cubesats, the Edison Demonstration of Smallsat Networks (EDSN) project, will demonstrate intra-swarm communications and multi-point in-situ space physics data acquisition. In support of the design and testing of the EDSN satellites, a geometrically accurate thermal model has been constructed. Due to the low duty cycle of most components, no significant overheating issues were found. The predicted mininum temperatures of the external antennas are low enough, however, that some mitigation may be in order. The development and application of the model will be discussed in detail.

  11. 39 CFR 501.9 - Demonstration or test Postage Evidencing Systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... MANUFACTURE AND DISTRIBUTE POSTAGE EVIDENCING SYSTEMS § 501.9 Demonstration or test Postage Evidencing Systems. (a) A demonstration or test postage evidencing system is any system that produces an image that... 39 Postal Service 1 2010-07-01 2010-07-01 false Demonstration or test Postage Evidencing Systems...

  12. The Development of an Embedded Figures Test for the Detection of Feigned Attention Deficit Hyperactivity Disorder in Adulthood

    PubMed Central

    Fuermaier, Anselm B. M.; Tucha, Oliver; Koerts, Janneke; Grabski, Meryem; Lange, Klaus W.; Weisbrod, Matthias; Aschenbrenner, Steffen; Tucha, Lara

    2016-01-01

    Objectives It has been shown that an increasing number of adults deliberately feign attention deficit hyperactivity disorder (ADHD), which demonstrates the need for new tests designed to detect feigned ADHD. Methods An Embedded Figures Test (EFT) was developed for the detection of feigned ADHD in adulthood. EFT performance of 51 adults with ADHD was compared to the performance of 52 matched healthy individuals, as well as to 268 undergraduate students who were randomly allocated in a simulation design to one of four experimental conditions, i.e. a control group, a naïve simulation group, a symptom-coached simulation group or a test-coached simulation group. Furthermore, an independent sample of 11 adults with ADHD as well as a sample of 17 clinicians experienced in the work with adults with ADHD were assessed for further validation of the EFT. Results The EFT was relatively easy to perform for both patients with ADHD and healthy comparisons as shown by low error rates and non-significant group differences. However, simulation groups differed from patients with ADHD by significant and large effects. An EFT index for the prediction of feigned ADHD was derived based on logistic regression coefficients. Receiver Operating Characteristics (ROC) demonstrated good classification accuracy of feigned ADHD relative to ADHD (AUC = 94.8%), i.e. high sensitivity (88%) and specificity (90%). Conclusions This study supports the utility of the EFT for the detection of feigned adult ADHD. PMID:27732620

  13. Measurement uncertainty analysis techniques applied to PV performance measurements

    NASA Astrophysics Data System (ADS)

    Wells, C.

    1992-10-01

    The purpose of this presentation is to provide a brief introduction to measurement uncertainty analysis, outline how it is done, and illustrate uncertainty analysis with examples drawn from the PV field, with particular emphasis toward its use in PV performance measurements. The uncertainty information we know and state concerning a PV performance measurement or a module test result determines, to a significant extent, the value and quality of that result. What is measurement uncertainty analysis? It is an outgrowth of what has commonly been called error analysis. But uncertainty analysis, a more recent development, gives greater insight into measurement processes and tests, experiments, or calibration results. Uncertainty analysis gives us an estimate of the interval about a measured value or an experiment's final result within which we believe the true value of that quantity will lie. Why should we take the time to perform an uncertainty analysis? A rigorous measurement uncertainty analysis: Increases the credibility and value of research results; allows comparisons of results from different labs; helps improve experiment design and identifies where changes are needed to achieve stated objectives (through use of the pre-test analysis); plays a significant role in validating measurements and experimental results, and in demonstrating (through the post-test analysis) that valid data have been acquired; reduces the risk of making erroneous decisions; demonstrates quality assurance and quality control measures have been accomplished; define Valid Data as data having known and documented paths of: Origin, including theory; measurements; traceability to measurement standards; computations; uncertainty analysis of results.

  14. The Development of an Embedded Figures Test for the Detection of Feigned Attention Deficit Hyperactivity Disorder in Adulthood.

    PubMed

    Fuermaier, Anselm B M; Tucha, Oliver; Koerts, Janneke; Grabski, Meryem; Lange, Klaus W; Weisbrod, Matthias; Aschenbrenner, Steffen; Tucha, Lara

    2016-01-01

    It has been shown that an increasing number of adults deliberately feign attention deficit hyperactivity disorder (ADHD), which demonstrates the need for new tests designed to detect feigned ADHD. An Embedded Figures Test (EFT) was developed for the detection of feigned ADHD in adulthood. EFT performance of 51 adults with ADHD was compared to the performance of 52 matched healthy individuals, as well as to 268 undergraduate students who were randomly allocated in a simulation design to one of four experimental conditions, i.e. a control group, a naïve simulation group, a symptom-coached simulation group or a test-coached simulation group. Furthermore, an independent sample of 11 adults with ADHD as well as a sample of 17 clinicians experienced in the work with adults with ADHD were assessed for further validation of the EFT. The EFT was relatively easy to perform for both patients with ADHD and healthy comparisons as shown by low error rates and non-significant group differences. However, simulation groups differed from patients with ADHD by significant and large effects. An EFT index for the prediction of feigned ADHD was derived based on logistic regression coefficients. Receiver Operating Characteristics (ROC) demonstrated good classification accuracy of feigned ADHD relative to ADHD (AUC = 94.8%), i.e. high sensitivity (88%) and specificity (90%). This study supports the utility of the EFT for the detection of feigned adult ADHD.

  15. A Longitudinal Operant Assessment of Cognitive and Behavioural Changes in the HdhQ111 Mouse Model of Huntington’s Disease

    PubMed Central

    Dunnett, Stephen B.; Brooks, Simon P.

    2016-01-01

    Huntington’s disease (HD) is characterised by motor symptoms which are often preceded by cognitive and behavioural changes, that can significantly contribute to disease burden for people living with HD. Numerous knock-in mouse models of HD are currently available for scientific research. However, before their use, they must be behaviourally characterised to determine their suitability in recapitulating the symptoms of the human condition. Thus, we sought to longitudinally characterise the nature, severity and time course of cognitive and behavioural changes observed in HdhQ111 heterozygous knock-in mice.To determine changes in cognition and behaviour an extensive battery of operant tests including: fixed ratio, progressive ratio, the five choice serial reaction time task and the serial implicit learning task, were applied longitudinally to HdhQ111 and wild type mice. The operant test battery was conducted at 6, 12 and 18 months of age. Significant deficits were observed in HdhQ111 animals in comparison to wild type animals in all operant tests indicating altered cognition (attentional and executive function) and motivation. However, the cognitive and behavioural deficits observed were not shown to be progressive over time in the longitudinal testing paradigm that was utilised. The results therefore demonstrate that the HdhQ111 mouse model of HD reflects some features of the cognitive and behavioural changes shown in the human condition of HD. Although, the cognitive and behavioural deficits demonstrated were not shown to be progressive over time. PMID:27701442

  16. Relative efficacy for radiation reducing methods in scoliotic patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aikenhead, J.; Triano, J.; Baker, J.

    Radiation dosages to sensitive organs in full spine radiography have in recent years been a concern of physicians as well as the general public. The spine is the prime target for exposure in scoliosis radiography, though the exposure usually necessitates irradiation of several radio-sensitive organs. In recent studies, various protection techniques have been used including various lead and aluminum filtration systems, altered patient positioning and varied tube-film distances. The purpose of this study was to evaluate the efficiency for radiation dosage reduction of three filtration systems used frequently in the chiropractic profession. The systems tested were the Nolan Multiple X-raymore » Filters, the Clear-Pb system and the Sportelli Wedge system. These systems were tested in seven configurations varying breast shielding, distance and patient positioning. All systems tested demonstrated significant radiation reductions to organs, especially breast tissue. The Clear-Pb system appeared to be the most effective for all organs except the breast, and the Sportelli Wedge system demonstrated the greatest reduction to breast tissue.« less

  17. Aniracetam reverses memory impairment in rats.

    PubMed

    Martin, J R; Moreau, J L; Jenck, F

    1995-02-01

    The pyrrolidinone derivative aniracetam given orally immediately after acquisition of an inhibitory avoidance response reproducibly ameliorated scopolamine-induced amnesia in female rats in an extensive series of test sessions conducted over a 1-year period. In a dose-response experiment it was demonstrated that 50 mg kg-1 was the lowest oral dose of aniracetam to significantly ameliorate scopolamine-induced amnesia. Combined results from these numerous test sessions demonstrated that 50 mg kg-1 aniracetam administered to scopolamine-treated rats resulted in 53% of the animals exhibiting correct passive avoidance responding in the retention evaluation versus 9% of the scopolamine-treated rats given vehicle (in comparison, 64% of the rats injected with vehicle rather than scopolamine in this experimental situation exhibited correct responding in the retention test). There was minimal variation in this pattern of results over the successive 1-month blocks constituting the complete experimental period. Thus, the nootropic compound aniracetam replicably exhibited memory enhancing effects in this animal model of reduced cholinergic function.

  18. Vacuum Compatibility of Flux-Core Arc Welding (FCAW)

    NASA Astrophysics Data System (ADS)

    Arose, Dana; Denault, Martin; Jurcznski, Stephan

    2010-11-01

    Typically, vacuum chambers are welded together using gas tungsten arc welding (GTAW) or gas metal arc welding (GMAW). This is demonstrated in the vacuum chamber of Princeton Plasma Physics Lab's (PPPL) National Spherical Torus Experiment (NSTX). These processes are slow and apply excess heat to the base metal, which may cause the vacuum chamber to deform beyond designed tolerance. Flux cored arc welding (FCAW) avoids these problems, but may produce an unacceptable amount of outgasing due to the flux shielding. We believe impurities due to outgasing from FCAW will not greatly exceed those found in GTAW and GMAW welding. To test this theory, samples welded together using all three welding processes will be made and baked in a residual gas analyzer (RGA). The GTAW and GMAW welds will be tested to establish a metric for permissible outgasing. By testing samples from all three processes we hope to demonstrate that FCAW does not significantly outgas, and is therefore a viable alternative to GTAW and GMAW. Results from observations will be presented.

  19. DESIGNING AN OPPORTUNITY FUEL WITH BIOMASS AND TIRE-DERIVED FUEL FOR COFIRING AT WILLOW ISLAND GENERATING STATION AND COFIRING SAWDUST WITH COAL AT ALBRIGHT GENERATING STATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    K. Payette; D. Tillman

    During the period July 1, 2001--September 30, 2001, Allegheny Energy Supply Co., LLC (Allegheny) continued construction of the Willow Island cofiring project, completed the installation of the fuel storage facility, the fuel receiving facility, and the processing building. All mechanical equipment has been installed and electrical construction has proceeded. During this time period significant short term testing of the Albright Generating Station cofiring facility was completed, and the 100-hour test was planned for early October. The testing demonstrated that cofiring at the Albright Generating Station could contribute to a ''4P Strategy''--reduction of SO{sub 2}, NO{sub x}, mercury, and greenhouse gasmore » emissions. This report summarizes the activities associated with the Designer Opportunity Fuel program, and demonstrations at Willow Island and Albright Generating Stations. It details the construction activities at both sites along with the combustion modeling at the Willow Island site.« less

  20. Pseudo-dynamic tests on masonry residential buildings seismically retrofitted by precast steel reinforced concrete walls

    NASA Astrophysics Data System (ADS)

    Li, Wenfeng; Wang, Tao; Chen, Xi; Zhong, Xiang; Pan, Peng

    2017-07-01

    A retrofitting technology using precast steel reinforced concrete (PSRC) panels is developed to improve the seismic performance of old masonry buildings. The PSRC panels are built up as an external PSRC wall system surrounding the existing masonry building. The PSRC walls are well connected to the existing masonry building, which provides enough confinement to effectively improve the ductility, strength, and stiffenss of old masonry structures. The PSRC panels are prefabricated in a factory, significantly reducing the situ work and associated construction time. To demonstrate the feasibility and mechanical effectivenss of the proposed retrofitting system, a full-scale five-story specimen was constructed. The retrofitting process was completed within five weeks with very limited indoor operation. The specimen was then tested in the lateral direction, which could potentially suffer sigifnicant damage in a large earthquake. The technical feasibility, construction workability, and seismic performance were thoroughly demonstrated by a full-scale specimen construction and pseudo-dynamic tests.

  1. Advanced modulation technology development for earth station demodulator applications. Coded modulation system development

    NASA Technical Reports Server (NTRS)

    Miller, Susan P.; Kappes, J. Mark; Layer, David H.; Johnson, Peter N.

    1990-01-01

    A jointly optimized coded modulation system is described which was designed, built, and tested by COMSAT Laboratories for NASA LeRC which provides a bandwidth efficiency of 2 bits/s/Hz at an information rate of 160 Mbit/s. A high speed rate 8/9 encoder with a Viterbi decoder and an Octal PSK modem are used to achieve this. The BER performance is approximately 1 dB from the theoretically calculated value for this system at a BER of 5 E-7 under nominal conditions. The system operates in burst mode for downlink applications and tests have demonstrated very little degradation in performance with frequency and level offset. Unique word miss rate measurements were conducted which demonstrate reliable acquisition at low values of Eb/No. Codec self tests have verified the performance of this subsystem in a stand alone mode. The codec is capable of operation at a 200 Mbit/s information rate as demonstrated using a codec test set which introduces noise digitally. The measured performance is within 0.2 dB of the computer simulated predictions. A gate array implementation of the most time critical element of the high speed Viterbi decoder was completed. This gate array add-compare-select chip significantly reduces the power consumption and improves the manufacturability of the decoder. This chip has general application in the implementation of high speed Viterbi decoders.

  2. A pre-test and post-test study of the physical and psychological effects of out-of-home respite care on caregivers of children with life-threatening conditions.

    PubMed

    Remedios, Cheryl; Willenberg, Lisa; Zordan, Rachel; Murphy, Andrea; Hessel, Gail; Philip, Jennifer

    2015-03-01

    Respite services are recommended as an important support for caregivers of children with life-threatening conditions. However, the benefits of respite have not been convincingly demonstrated through quantitative research. To determine the impact of out-of home respite care on levels of fatigue, psychological adjustment, quality of life and relationship satisfaction among caregivers of children with life-threatening conditions. A mixed-methods, pre-test and post-test study A consecutive sample of 58 parental caregivers whose children were admitted to a children's hospice for out-of-home respite over an average of 4 days. Caregivers had below-standard levels of quality of life compared to normative populations. Paired t-tests demonstrated that caregivers' average psychological adjustment scores significantly improved from pre-respite (mean = 13.9, standard error = 0.71) to post-respite (mean = 10.7, standard error = 1); p < 0.001, 95% confidence interval: 1.25-5.11). Furthermore, caregivers' average fatigue scores significantly improved from pre-respite (mean = 14.3, standard error = 0.85) to post-respite (mean = 10.9, standard error = 1.01; p < 0.001, 95% confidence interval: 1.69-7.94), and caregivers' average mental health quality of life scores significantly improved from pre-respite (mean = 44.2, standard error = 1.8) to post-respite (mean = 49.1, standard error = 1.6; p < 0.01, 95% confidence interval: -9.56 to 0.36). Qualitative data showed caregivers sought respite for relief from intensive care provision and believed this was essential to their well-being. Findings indicate the effectiveness of out-of-home respite care in improving the fatigue and psychological adjustment of caregivers of children with life-threatening conditions. Study outcomes inform service provision and future research efforts in paediatric palliative care. © The Author(s) 2015.

  3. Improvement of Carbon Dioxide Sweep Efficiency by Utilization of Microbial Permeability Profile Modification to Reduce the Amount of Oil Bypassed During Carbon Dioxide Flood

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmitz, Darrel; Brown, Lewis; Lynch, F. Leo

    2010-12-31

    The objective of this project was to couple microbial permeability profile modification (MPPM), with carbon dioxide flooding to improve oil recovery from the Upper Cretaceous Little Creek Oil Field situated in Lincoln and Pike counties, MS. This study determined that MPPM technology, which improves production by utilizing environmentally friendly nutrient solutions to simulate the growth of the indigenous microflora in the most permeable zones of the reservoir thus diverting production to less permeable, previously unswept zones, increased oil production without interfering with the carbon dioxide flooding operation. Laboratory tests determined that no microorganisms were produced in formation waters, but weremore » present in cores. Perhaps the single most significant contribution of this study is the demonstration that microorganisms are active at a formation temperature of 115°C (239°F) by using a specially designed culturing device. Laboratory tests were employed to simulate the MPPM process by demonstrating that microorganisms could be activated with the resulting production of oil in coreflood tests performed in the presence of carbon dioxide at 66°C (the highest temperature that could be employed in the coreflood facility). Geological assessment determined significant heterogeneity in the Eutaw Formation, and documented relatively thin, variably-lithified, well-laminated sandstone interbedded with heavily-bioturbated, clay-rich sandstone and shale. Live core samples of the Upper Cretaceous Eutaw Formation from the Heidelberg Field, MS were quantitatively assessed using SEM, and showed that during MPPM permeability modification occurs ubiquitously within pore and throat spaces of 10-20 μm diameter. Testing of the MPPM procedure in the Little Creek Field showed a significant increase in production occurred in two of the five production test wells; furthermore, the decline curve in each of the production wells became noticeably less steep. This project greatly extends the number of oil fields in which MPPM can be implemented.« less

  4. Comparison between videotape and personal teaching as methods of communicating clinical skills to medical students.

    PubMed Central

    Mir, M A; Marshall, R J; Evans, R W; Hall, R; Duthie, H L

    1984-01-01

    The efficacy of video recording in transmitting clinical knowledge and skills to medical students was tested by recording on videotape demonstrations of physical examinations given by five clinicians to a randomly selected group of 12 students (personal group) from the first clinical year and then showing these recordings, under identical conditions, to 13 students from the same year (video group). The efficacy of both the personal and video mediums in terms of whether content was retained was tested by a questionnaire completed by all students at the end of the sessions and by a structured clinical assessment in which students were asked to demonstrate some of the same clinical tasks three weeks after the demonstration. In answering the questionnaire the video group obtained a mean (SD) score of 20.8 (7.0) (maximum possible score 40), which was not significantly different from the score achieved by the personal group (17.4 (7.7)). The video group was able to reproduce 44 (10)% of the total clinical steps demonstrated and the personal group 45 (14)%. Videotaped demonstrations can be as effective as personal teaching of clinical methods, and video should be developed as a medium for first line clinical teaching. PMID:6428655

  5. The Caledonian face test: A new test of face discrimination.

    PubMed

    Logan, Andrew J; Wilkinson, Frances; Wilson, Hugh R; Gordon, Gael E; Loffler, Gunter

    2016-02-01

    This study aimed to develop a clinical test of face perception which is applicable to a wide range of patients and can capture normal variability. The Caledonian face test utilises synthetic faces which combine simplicity with sufficient realism to permit individual identification. Face discrimination thresholds (i.e. minimum difference between faces required for accurate discrimination) were determined in an "odd-one-out" task. The difference between faces was controlled by an adaptive QUEST procedure. A broad range of face discrimination sensitivity was determined from a group (N=52) of young adults (mean 5.75%; SD 1.18; range 3.33-8.84%). The test is fast (3-4 min), repeatable (test-re-test r(2)=0.795) and demonstrates a significant inversion effect. The potential to identify impairments of face discrimination was evaluated by testing LM who reported a lifelong difficulty with face perception. While LM's impairment for two established face tests was close to the criterion for significance (Z-scores of -2.20 and -2.27) for the Caledonian face test, her Z-score was -7.26, implying a more than threefold higher sensitivity. The new face test provides a quantifiable and repeatable assessment of face discrimination ability. The enhanced sensitivity suggests that the Caledonian face test may be capable of detecting more subtle impairments of face perception than available tests. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. The application of soccer performance testing protocols to the non-elite player.

    PubMed

    Siegler, J; Robergs, R; Weingart, H

    2006-03-01

    The application of performance testing for the evaluation of non-elite soccer players has received little attention. The purpose of this investigation was to use tests developed for elite soccer players to evaluate performance in non-elite soccer players and compare performance test results between elite (literature) and non-elite (data) players. Thirteen male soccer players volunteered to participate. The tests included a treadmill VO2max test, 20 m sprint, vertical jump (VJ), 30 s Wingate cycle ergometer test, the Loughborough Intermittent Shuttle Test (LIST), and 2 20-m multi-stage shuttle runs to exhaustion (fatigue test). Actual VO2max (absolute and relative) scores were correlated with the estimated VO2max scores (fatigue test), 20 m sprint, VJ, and 30 s Wingate using a Pearson's product-moment correlation. A paired t-test was conducted on the fatigue test trials. Non-significant relationships were observed between actual VO2max scores and estimated VO2max from the fatigue test (absolute and relative terms). Non-significant relationships were also observed between peak and average power output (Wingate), 20 m sprint, and VJ. Mean heart rates (HRs) throughout the LIST was 165+/-7 bpm, which represented 88% of HRmax. The results of this study demonstrate that to elicit physiological differences between elite and non-elite players, assessment must include both an aerobic and anaerobic component.

  7. A study to compare traditional and constructivism-based instruction of a high school biology unit on biosystematics

    NASA Astrophysics Data System (ADS)

    Saigo, Barbara Woodworth

    The researcher collaborated with four high school biology teachers who had been involved for 2-1/2 years in a constructivism-based professional development experience that emphasized teaching for conceptual change and using classroom-based inquiry as a basis for making instructional decisions. The researcher and teachers designed a five-day instructional unit on biosystematics using two contrasting approaches, comprising the treatment variable. The "traditional" unit emphasized lecture, written materials, and some laboratory activities. The "constructivist" unit emphasized a specific, inquiry-based, conceptual change strategy and collaborative learning. The study used a quasi-experimental, factorial design to explore impact of instructional approach (the treatment variable) on student performance (the dependent variable) on repeated measures (three) of a biology concept test. Additional independent variables considered were gender, cumulative GPA, and the section in which students were enrolled. Scores on the biology concept test were compiled for the 3 constructivist sections (N = 44) and the 3 traditional sections (N = 42). Analysis of Covariance (ANCOVA) was applied. The main findings in regard to the primary research question were that instructional approach did not have a significant relationship to immediate post test scores or gain, but that one month after instruction students in the constructivist group demonstrated less loss of gain than those in the traditional group; i.e., their longer-term retention was greater. Also, GPA*instructional approach effects were detected for post-post-test gain. GPA and gender were significantly associated with pre-test, post-test, and post-post scores; however, in terms of change (gain) from pre-test to post-test and pre-test to post-post-test, GPA and gender were not significant effects. Section was a significant effect for all three tests, in terms of both score and gain. Gender*section effects were detected for post-test gain and post-post-test scores.

  8. Solid Polymer Electrolyte (SPE) fuel cell technology program

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The overall objectives of the Phase IV Solid Polymer Electrolyte Fuel Cell Technology Program were to: (1) establish fuel cell life and performance at temperatures, pressures and current densities significantly higher than those previously demonstrated; (2) provide the ground work for a space energy storage system based on the solid polymer electrolyte technology (i.e., regenerative H2/O2 fuel cell); (3) design, fabricate and test evaluate a full-scale single cell unit. During this phase, significant progress was made toward the accomplishment of these objectives.

  9. A comparison of transient vehicle performance using a fixed geometry, wastegated turbocharger and a variable geometry turbocharger

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lundstrom, R.R.; Gall, J.M.

    1986-01-01

    The use of an exhaust-driven boosting device can significantly improve the performance of a vehicle using a small displacement engine. One of the concerns relative to the performance of vehicles using these devices is ''turbo lag,'' or the period of time during which no boost is generated. This paper presents the results of designed experiments comparing the performance of a fixed geometry, wastegated turbocharger to a variable geometry turbocharger incorporating a low-loss bearing system. In addition, experimental tests are presented for the naturally aspirated engine in the same vehicle. The results of the experiments show improvements with the use ofmore » pressure boosting and that there are signifcant differences in the boosting devices tested; specifically, the use of a variable geometry turbocharger demonstrates significant reduction in the length of time required to reach boost and reduced acceleration times for the tests conducted.« less

  10. Test of Gross Motor Development-3 (TGMD-3) with the Use of Visual Supports for Children with Autism Spectrum Disorder: Validity and Reliability.

    PubMed

    Allen, K A; Bredero, B; Van Damme, T; Ulrich, D A; Simons, J

    2017-03-01

    The validity and reliability of the Test of Gross Motor Development-3 (TGMD-3) were measured, taking into consideration the preference for visual learning of children with autism spectrum disorder (ASD). The TGMD-3 was administered to 14 children with ASD (4-10 years) and 21 age-matched typically developing children under two conditions: TGMD-3 traditional protocol, and TGMD-3 visual support protocol. Excellent levels of internal consistency, test-retest, interrater and intrarater reliability were achieved for the TGMD-3 visual support protocol. TGMD-3 raw scores of children with ASD were significantly lower than typically developing peers, however, significantly improved using the TGMD-3 visual support protocol. This demonstrates that the TGMD-3 visual support protocol is a valid and reliable assessment of gross motor performance for children with ASD.

  11. Super-recognizers: People with extraordinary face recognition ability

    PubMed Central

    Russell, Richard; Duchaine, Brad; Nakayama, Ken

    2014-01-01

    We tested four people who claimed to have significantly better than ordinary face recognition ability. Exceptional ability was confirmed in each case. On two very different tests of face recognition, all four experimental subjects performed beyond the range of control subject performance. They also scored significantly better than average on a perceptual discrimination test with faces. This effect was larger with upright than inverted faces, and the four subjects showed a larger ‘inversion effect’ than control subjects, who in turn showed a larger inversion effect than developmental prosopagnosics. This indicates an association between face recognition ability and the magnitude of the inversion effect. Overall, these ‘super-recognizers’ are about as good at face recognition and perception as developmental prosopagnosics are bad. Our findings demonstrate the existence of people with exceptionally good face recognition ability, and show that the range of face recognition and face perception ability is wider than previously acknowledged. PMID:19293090

  12. Super-recognizers: people with extraordinary face recognition ability.

    PubMed

    Russell, Richard; Duchaine, Brad; Nakayama, Ken

    2009-04-01

    We tested 4 people who claimed to have significantly better than ordinary face recognition ability. Exceptional ability was confirmed in each case. On two very different tests of face recognition, all 4 experimental subjects performed beyond the range of control subject performance. They also scored significantly better than average on a perceptual discrimination test with faces. This effect was larger with upright than with inverted faces, and the 4 subjects showed a larger "inversion effect" than did control subjects, who in turn showed a larger inversion effect than did developmental prosopagnosics. This result indicates an association between face recognition ability and the magnitude of the inversion effect. Overall, these "super-recognizers" are about as good at face recognition and perception as developmental prosopagnosics are bad. Our findings demonstrate the existence of people with exceptionally good face recognition ability and show that the range of face recognition and face perception ability is wider than has been previously acknowledged.

  13. Relation between functional mobility and dynapenia in institutionalized frail elderly.

    PubMed

    Soares, Antonio Vinicius; Marcelino, Elessandra; Maia, Késsia Cristina; Borges, Noé Gomes

    2017-01-01

    To investigate the relation between functional mobility and dynapenia in institutionalized frail elderly. A descriptive, correlational study involving 26 institutionalized elderly men and women, mean age 82.3±6 years. The instruments employed were the Mini Mental State Examination, the Geriatric Depression Scale, the International Physical Activity Questionnaire, the Timed Up and Go test, a handgrip dynamometer and a portable dynamometer for large muscle groups (shoulder, elbow and hip flexors, knee extensors and ankle dorsiflexors). Significant negative correlation between functional mobility levels assessed by the Timed Up and Go test and dynapenia was observed in all muscle groups evaluated, particularly in knee extensors (r -0.65). A significant negative correlation between muscle strength, particularly knee extensor strength, and functional mobility was found in institutionalized elderly. Data presented indicate that the higher the muscle strength, the shorter the execution time, and this could demonstrate better performance in this functional mobility test.

  14. Rapid and Sensitive Detection of Protein Biomarker Using a Portable Fluorescence Biosensor based on Quantum Dots and a Lateral Flow Test Strip

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Zhaohui; Wang, Ying; Wang, Jun

    2010-08-15

    A portable fluorescence biosensor with rapid and ultrasensitive response for trace protein has been built up with quantum dots and lateral flow test strip. The superior signal brightness and high photostability of quantum dots are combined with the promising advantages of lateral flow test strip and resulted in high sensitivity, selectivity and speedy for protein detection. Nitrated ceruloplasmin, a significant biomarker for cardiovascular disease, lung cancer and stress response to smoking, was used as model protein to demonstrate the good performances of this proposed Qdot-based lateral flow test strip. Quantitative detection of nitrated ceruloplasmin was realized by recording the fluorescencemore » intensity of quantum dots captured on the test line. Under optimal conditions, this portable fluorescence biosensor displays rapid responses for nitrated ceruloplasmin in wide dynamic range with a detection limit of 0.1ng/mL (S/N=3). Furthermore, the biosensor was successfully utilized for spiked human plasma sample detection with the concentration as low as 1ng/mL. The results demonstrate that the quantum dot-based lateral flow test strip is capable for rapid, sensitive, and quantitative detection of nitrated ceruloplasmin and hold a great promise for point-of-care and in field analysis of other protein biomarkers.« less

  15. Results from an Interval Management (IM) Flight Test and Its Potential Benefit to Air Traffic Management Operations

    NASA Technical Reports Server (NTRS)

    Baxley, Brian; Swieringa, Kurt; Berckefeldt, Rick; Boyle, Dan

    2017-01-01

    NASA's first Air Traffic Management Technology Demonstration (ATD-1) subproject successfully completed a 19-day flight test of an Interval Management (IM) avionics prototype. The prototype was built based on IM standards, integrated into two test aircraft, and then flown in real-world conditions to determine if the goals of improving aircraft efficiency and airport throughput during high-density arrival operations could be met. The ATD-1 concept of operation integrates advanced arrival scheduling, controller decision support tools, and the IM avionics to enable multiple time-based arrival streams into a high-density terminal airspace. IM contributes by calculating airspeeds that enable an aircraft to achieve a spacing interval behind the preceding aircraft. The IM avionics uses its data (route of flight, position, etc.) and Automatic Dependent Surveillance-Broadcast (ADS-B) state data from the Target aircraft to calculate this airspeed. The flight test demonstrated that the IM avionics prototype met the spacing accuracy design goal for three of the four IM operation types tested. The primary issue requiring attention for future IM work is the high rate of IM speed commands and speed reversals. In total, during this flight test, the IM avionics prototype showed significant promise in contributing to the goals of improving aircraft efficiency and airport throughput.

  16. Testing and Analysis of a Composite Non-Cylindrical Aircraft Fuselage Structure . Part II; Severe Damage

    NASA Technical Reports Server (NTRS)

    Przekop, Adam; Jegley, Dawn C.; Lovejoy, Andrew E.; Rouse, Marshall; Wu, Hsi-Yung T.

    2016-01-01

    The Environmentally Responsible Aviation Project aimed to develop aircraft technologies enabling significant fuel burn and community noise reductions. Small incremental changes to the conventional metallic alloy-based 'tube and wing' configuration were not sufficient to achieve the desired metrics. One airframe concept identified by the project as having the potential to dramatically improve aircraft performance was a composite-based hybrid wing body configuration. Such a concept, however, presented inherent challenges stemming from, among other factors, the necessity to transfer wing loads through the entire center fuselage section which accommodates a pressurized cabin confined by flat or nearly flat panels. This paper discusses a finite element analysis and the testing of a large-scale hybrid wing body center section structure developed and constructed to demonstrate that the Pultruded Rod Stitched Efficient Unitized Structure concept can meet these challenging demands of the next generation airframes. Part II of the paper considers the final test to failure of the test article in the presence of an intentionally inflicted severe discrete source damage under the wing up-bending loading condition. Finite element analysis results are compared with measurements acquired during the test and demonstrate that the hybrid wing body test article was able to redistribute and support the required design loads in a severely damaged condition.

  17. A close examination of double filtering with fold change and t test in microarray analysis

    PubMed Central

    2009-01-01

    Background Many researchers use the double filtering procedure with fold change and t test to identify differentially expressed genes, in the hope that the double filtering will provide extra confidence in the results. Due to its simplicity, the double filtering procedure has been popular with applied researchers despite the development of more sophisticated methods. Results This paper, for the first time to our knowledge, provides theoretical insight on the drawback of the double filtering procedure. We show that fold change assumes all genes to have a common variance while t statistic assumes gene-specific variances. The two statistics are based on contradicting assumptions. Under the assumption that gene variances arise from a mixture of a common variance and gene-specific variances, we develop the theoretically most powerful likelihood ratio test statistic. We further demonstrate that the posterior inference based on a Bayesian mixture model and the widely used significance analysis of microarrays (SAM) statistic are better approximations to the likelihood ratio test than the double filtering procedure. Conclusion We demonstrate through hypothesis testing theory, simulation studies and real data examples, that well constructed shrinkage testing methods, which can be united under the mixture gene variance assumption, can considerably outperform the double filtering procedure. PMID:19995439

  18. Is there inter-procedural transfer of skills in intraocular surgery? A randomized controlled trial.

    PubMed

    Thomsen, Ann Sofia Skou; Kiilgaard, Jens Folke; la Cour, Morten; Brydges, Ryan; Konge, Lars

    2017-12-01

    To investigate how experience in simulated cataract surgery impacts and transfers to the learning curves for novices in vitreoretinal surgery. Twelve ophthalmology residents without previous experience in intraocular surgery were randomized to (1) intensive training in cataract surgery on a virtual-reality simulator until passing a test with predefined validity evidence (cataract trainees) or to (2) no cataract surgery training (novices). Possible skill transfer was assessed using a test consisting of all 11 vitreoretinal modules on the EyeSi virtual-reality simulator. All participants repeated the test of vitreoretinal surgical skills until their performance curve plateaued. Three experienced vitreoretinal surgeons also performed the test to establish validity evidence. Analysis with independent samples t-tests was performed. The vitreoretinal test on the EyeSi simulator demonstrated evidence of validity, given statistically significant differences in mean test scores for the first repetition; experienced surgeons scored higher than novices (p = 0.023) and cataract trainees (p = 0.003). Internal consistency for the 11 modules of the test was acceptable (Cronbach's α = 0.73). Our findings did not indicate a transfer effect with no significant differences found between cataract trainees and novices in their starting scores (mean ± SD 381 ± 129 points versus 455 ± 82 points, p = 0.262), time to reach maximum performance level (10.7 ± 3.0 hr versus 8.7 ± 2.8 hr, p = 0.265), or maximum scores (785 ± 162 points versus 805 ± 73 points, p = 0.791). Pretraining in cataract surgery did not demonstrate any measurable effect on vitreoretinal procedural performance. The results of this study indicate that we should not anticipate extensive transfer of surgical skills when planning training programmes in intraocular surgery. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  19. Central administration of angiotensin IV rapidly enhances novel object recognition among mice.

    PubMed

    Paris, Jason J; Eans, Shainnel O; Mizrachi, Elisa; Reilley, Kate J; Ganno, Michelle L; McLaughlin, Jay P

    2013-07-01

    Angiotensin IV (Val(1)-Tyr(2)-Ile(3)-His(4)-Pro(5)-Phe(6)) has demonstrated potential cognitive-enhancing effects. The present investigation assessed and characterized: (1) dose-dependency of angiotensin IV's cognitive enhancement in a C57BL/6J mouse model of novel object recognition, (2) the time-course for these effects, (3) the identity of residues in the hexapeptide important to these effects and (4) the necessity of actions at angiotensin IV receptors for procognitive activity. Assessment of C57BL/6J mice in a novel object recognition task demonstrated that prior administration of angiotensin IV (0.1, 1.0, or 10.0, but not 0.01 nmol, i.c.v.) significantly enhanced novel object recognition in a dose-dependent manner. These effects were time dependent, with improved novel object recognition observed when angiotensin IV (0.1 nmol, i.c.v.) was administered 10 or 20, but not 30 min prior to the onset of the novel object recognition testing. An alanine scan of the angiotensin IV peptide revealed that replacement of the Val(1), Ile(3), His(4), or Phe(6) residues with Ala attenuated peptide-induced improvements in novel object recognition, whereas Tyr(2) or Pro(5) replacement did not significantly affect performance. Administration of the angiotensin IV receptor antagonist, divalinal-Ang IV (20 nmol, i.c.v.), reduced (but did not abolish) novel object recognition; however, this antagonist completely blocked the procognitive effects of angiotensin IV (0.1 nmol, i.c.v.) in this task. Rotorod testing demonstrated no locomotor effects with any angiotensin IV or divalinal-Ang IV dose tested. These data demonstrate that angiotensin IV produces a rapid enhancement of associative learning and memory performance in a mouse model that was dependent on the angiotensin IV receptor. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Central administration of angiotensin IV rapidly enhances novel object recognition among mice

    PubMed Central

    Paris, Jason J.; Eans, Shainnel O.; Mizrachi, Elisa; Reilley, Kate J.; Ganno, Michelle L.; McLaughlin, Jay P.

    2013-01-01

    Angiotensin IV (Val1-Tyr2-Ile3-His4-Pro5-Phe6) has demonstrated potential cognitive-enhancing effects. The present investigation assessed and characterized: (1) dose-dependency of angiotensin IV's cognitive enhancement in a C57BL/6J mouse model of novel object recognition, (2) the time-course for these effects, (3) the identity of residues in the hexapeptide important to these effects and (4) the necessity of actions at angiotensin IV receptors for pro-cognitive activity. Assessment of C57BL/6J mice in a novel object recognition task demonstrated that prior administration of angiotensin IV (0.1, 1.0, or 10.0, but not 0.01, nmol, i.c.v.) significantly enhanced novel object recognition in a dose-dependent manner. These effects were time dependent, with improved novel object recognition observed when angiotensin IV (0.1 nmol, i.c.v.) was administered 10 or 20, but not 30, min prior to the onset of the novel object recognition testing. An alanine scan of the angiotensin IV peptide revealed that replacement of the Val1, Ile3, His4, or Phe6 residues with Ala attenuated peptide-induced improvements in novel object recognition, whereas Tyr2 or Pro5 replacement did not significantly affect performance. Administration of the angiotensin IV receptor antagonist, divalinal-Ang IV (20 nmol, i.c.v.), reduced (but did not abolish) novel object recognition; however, this antagonist completely blocked the pro-cognitive effects of angiotensin IV (0.1 nmol, i.c.v.) in this task. Rotorod testing demonstrated no locomotor effects for any angiotensin IV or divalinal-Ang IV dose tested. These data demonstrate that angiotensin IV produces a rapid enhancement of associative learning and memory performance in a mouse model that was dependent on the angiotensin IV receptor. PMID:23416700

Top