Sample records for testing osl failures

  1. Three-dimensional radiation dosimetry based on optically-stimulated luminescence

    NASA Astrophysics Data System (ADS)

    Sadel, M.; Høye, E. M.; Skyt, P. S.; Muren, L. P.; Petersen, J. B. B.; Balling, P.

    2017-05-01

    A new approach to three-dimensional (3D) dosimetry based on optically-stimulated luminescence (OSL) is presented. By embedding OSL-active particles into a transparent silicone matrix (PDMS), the well-established dosimetric properties of an OSL material are exploited in a 3D-OSL dosimeter. By investigating prototype dosimeters in standard cuvettes in combination with small test samples for OSL readers, it is shown that a sufficient transparency of the 3D-OSL material can be combined with an OSL response giving an estimated >10.000 detected photons in 1 second per 1mm3 voxel of the dosimeter at a dose of 1 Gy. The dose distribution in the 3D-OSL dosimeters can be directly read out optically without the need for subsequent reconstruction by computational inversion algorithms. The dosimeters carry the advantages known from personal-dosimetry use of OSL: the dose distribution following irradiation can be stored with minimal fading for extended periods of time, and dosimeters are reusable as they can be reset, e.g. by an intense (bleaching) light field.

  2. Gamma response characterizations of optically stimulated luminescence (OSL) affects personal dosimetry

    NASA Astrophysics Data System (ADS)

    Monthonwattana, S.; Esor, J.; Rungseesumran, T.; Intang, A.

    2017-06-01

    Optically Stimulated Luminescence (OSL) is the current technique of personal dosimetry changed by Nuclear Technology Service Center instead of Thermoluminescence dosimetry (TLD) because OSL has more advantages, such as repeat reading and elimination of heating process. In this study, OSL was used to test the gamma response characterizations. Detailed OSL investigation on personal dosimetry was carried out in the dose range of 0.2 - 3.0 mSv. The batch homogeneity was 7.66%. R2 value of the linear regression was 0.9997. The difference ratio of angular dependence at ± 60° was 8.7%. Fading of the reading was about 3%.

  3. Radiotherapy dosimetry using a commercial OSL system.

    PubMed

    Viamonte, A; da Rosa, L A R; Buckley, L A; Cherpak, A; Cygler, J E

    2008-04-01

    A commercial optically stimulated luminescence (OSL) system developed for radiation protection dosimetry by Landauer, Inc., the InLight microStar reader, was tested for dosimetry procedures in radiotherapy. The system uses carbon-doped aluminum oxide, Al2O3:C, as a radiation detector material. Using this OSL system, a percent depth dose curve for 60Co gamma radiation was measured in solid water. Field size and SSD dependences of the detector response were also evaluated. The dose response relationship was investigated between 25 and 400 cGy. The decay of the response with time following irradiation and the energy dependence of the Al2O3:C OSL detectors were also measured. The results obtained using OSL dosimeters show good agreement with ionization chamber and diode measurements carried out under the same conditions. Reproducibility studies show that the response of the OSL system to repeated exposures is 2.5% (1sd), indicating a real possibility of applying the Landauer OSL commercial system for radiotherapy dosimetric procedures.

  4. OSL response bleaching of BeO samples, using fluorescent light and blue LEDs

    NASA Astrophysics Data System (ADS)

    Groppo, D. P.; Caldas, L. V. E.

    2016-07-01

    The optically stimulated luminescence (OSL) is widely used as a dosimetric technique for many applications. In this work, the OSL response bleaching of BeO samples was studied. The samples were irradiated using a beta radiation source (90Sr+90Y); the bleaching treatments (fluorescent light and blue LEDs) were performed, and the results were compared. Various optical treatment time intervals were tested until reaching the complete bleaching of the OSL response. The best combination of the time interval and bleaching type was analyzed.

  5. Performance of Al2O3:C optically stimulated luminescence dosimeters for clinical radiation therapy applications.

    PubMed

    Hu, B; Wang, Y; Zealey, W

    2009-12-01

    A commercial Optical Stimulated Luminescence (OSL) dosimetry system developed by Landauer was tested to analyse the possibility of using OSL dosimetry for external beam radiotherapy planning checks. Experiments were performed to determine signal sensitivity, dose response range, beam type/energy dependency, reproducibility and linearity. Optical annealing processes to test OSL material reusability were also studied. In each case the measurements were converted into absorbed dose. The experimental results show that OSL dosimetry provides a wide dose response range, good linearity and reproducibility for the doses up to 800cGy. The OSL output is linear with dose up to 600cGy range showing a maximum deviation from linearity of 2.0% for the doses above 600cGy. The standard deviation in response of 20 dosimeters was 3.0%. After optical annealing using incandescent light, the readout intensity decreased by approximately 98% in the first 30 minutes. The readout intensity, I, decreased after repeated optical annealing as a power law, given by I infinity t (-1.3). This study concludes that OSL dosimetry can provide an alternative dosimetry technique for use in in-vivo dosimetry if rigorous measurement protocols are established.

  6. OSL studies of local bricks for retrospective dosimetric application

    NASA Astrophysics Data System (ADS)

    Singh, A. K.; Menon, S. N.; Kadam, S. Y.; Koul, D. K.; Datta, D.

    2016-09-01

    Luminescence properties of quartz extracted from bricks has been reported worldwide for its use in dose estimation in case of nuclear or radiological accident. Accordingly, in this study the feasibility of utilizing the optically stimulated luminescence (OSL) emission of quartz extracted from red bricks collected from three different locations in and around Mumbai, India for retrospective dosimetry was explored. Thermoluminescence and OSL characterization of the samples were carried out. The growth curve, thermal stability and equivalent dose plateau of the OSL signal suggested the signals to be well behaving. Subsequently, the dose recovery tests carried for different administered doses, using single aliquot regenerative protocol, demonstrated the feasibility of the OSL emissions of these samples for dose evaluation in retrospective dosimetry.

  7. WE-AB-BRB-08: Progress Towards a 2D OSL Dosimetry System Using Al2O3:C Films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmed, M F; Yukihara, E; Schnell, E

    Purpose: To develop a 2D dosimetry system based on the optically stimulated luminescence (OSL) of Al{sub 2}O{sub 3}:C films for medical applications. Methods: A 2D laser scanning OSL reader was built for readout of newly developed Al2O3:C films (Landauer Inc.). An image reconstruction algorithm was developed to correct for inherent effects introduced by reader design and detector properties. The system was tested using irradiations with photon and carbon ion beams. A calibration was obtained using a 6 MV photon beam from clinical accelerator and the dose measurement precision was tested using a range of doses and different dose distributions (flatmore » field and wedge field). The dynamic range and performance of the system in the presence of large dose gradients was also tested using 430 MeV/u {sup 12}C single and multiple pencil beams. All irradiations were performed with Gafchromic EBT3 film for comparison. Results: Preliminary results demonstrate a near-linear OSL dose response to photon fields and the ability to measure dose in dose distributions such as flat field and wedge field. Tests using {sup 12}C pencil beam demonstrate ability to measure doses over four orders of magnitude. The dose profiles measured by the OSL film generally agreed well with that measured by the EBT3 film. The OSL image signal-to-noise ratio obtained in the current conditions require further improvement. On the other hand, EBT3 films had large uncertainties in the low dose region due to film-to-film or intra-film variation in the background. Conclusion: A 2D OSL dosimetry system was developed and initial tests have demonstrated a wide dynamic range as well as good agreement between the delivered and measured doses. The low background, wide dynamic range and wide range of linearity in dose response observed for the Al{sub 2}O{sub 3}:C OSL film can be beneficial for dosimetry in radiation therapy applications, especially for small field dosimetry. This work has been funded by Landauer Inc. Dr. Eduardo G. Yukihara also would like to thank the Alexander von Humboldt Foundation for his support at the DKFZ.« less

  8. OSL dating of fine-grained quartz from Holocene Yangtze delta sediments

    NASA Astrophysics Data System (ADS)

    Sugisaki, S.; Buylaert, J. P.; Murray, A. S.; Tada, R.; Zheng, H.; Ke, W.; Saito, K.; Irino, T.; Chao, L.; Shiyi, L.; Uchida, M.

    2014-12-01

    Flood events in the Yangtze River are associated with variation in East Asian Summer Monsoon (EASM) precipitation. Understanding the frequency and scale of the EASM precipitation during the Holocene is a key to understanding the mechanism and cyclicity of floods and droughts. Because about 70% of the annual discharge occurs during the flood season, the Yangtze delta sediments provide a good archive of EASM precipitation. In this study, we investigate the possibility of applying OSL dating to establishing high-resolution chronologies for the Yangtze delta sediment cores YD13-1H and G3. The objectives of this study are: (1) test whether fine grained quartz in present day suspended particle matter (SPM) is fully bleached or reset before deposition, (2) where possible, test quartz fine- and coarse-grain OSL dating against radiocarbon shell ages, (3) interpret the sediment transport processes through the differential bleaching of quartz and feldspar OSL signals. We show that the SPM collected from the surface water column of the Yangtze River during the flood season is well-bleached (offset ~60 years). Fine-grained pro-delta sediments are thus potentially a good dosimeter for OSL dating. OSL ages sediment cores indicate a pronounced change in sedimentation rate at ~6 ka and ~2ka. These events are consistent with what is known of the evolution of the Yangtze catchment and delta. The delta began to build at ~6 ka (Zhao et al., 1979), and human activities increased significantly in the catchment at ~2ka (Chen et al., 1985). It is however surprising that the entire top 9 m of sediment only records these two events. The question of whether significant deposition was limited to 2 ka and 6 ka, or whether the record has been disturbed by erosion/reworking remains. These issues are discussed in terms of the reliability of the quartz OSL ages, the degree of bleaching by comparison with polymineral OSL signals, and the relationship of the OSL ages to the sedimentary record.

  9. Measurements of eye lens doses in interventional cardiology using OSL and electronic dosemeters†.

    PubMed

    Sanchez, R M; Vano, E; Fernandez, J M; Ginjaume, M; Duch, M A

    2014-12-01

    The purpose of this paper is to test the appropriateness of OSL and electronic dosemeters to estimate eye lens doses at interventional cardiology environment. Using TLD as reference detectors, personal dose equivalent was measured in phantoms and during clinical procedures. For phantom measurements, OSL dose values resulted in an average difference of -15 % vs. TLD. Tests carried out with other electronic dosemeters revealed differences up to ±20 % versus TLD. With dosemeters positioned outside the goggles and when TLD doses were >20 μSv, the average difference OSL vs. TLD was -9 %. Eye lens doses of almost 700 μSv per procedure were measured in two cases out of a sample of 33 measurements in individual clinical procedures, thus showing the risk of high exposure to the lenses of the eye when protection rules are not followed. The differences found between OSL and TLD are acceptable for the purpose and range of doses measured in the survey. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. High resolution optically stimulated luminescence dating of a sediment core from the southwestern Sea of Okhotsk

    NASA Astrophysics Data System (ADS)

    Sugisaki, S.; Buylaert, J. P.; Murray, A. S.; Harada, N.; Kimoto, K.; Okazaki, Y.; Sakamoto, T.; Iijima, K.; Tsukamoto, S.; Miura, H.; Nogi, Y.

    2012-05-01

    Optically stimulated luminescence (OSL) dating is now widely accepted as a chronometer for terrestrial sediment. More recently, it has been suggested that OSL may also be useful in the dating of deep-sea marine sediments. In this paper, we test the usefulness of high resolution quartz OSL dating in application to a 19 m marine sediment core (MR0604-PC04A) taken from the southwestern Sea of Okhotsk, immediately to the north of Hokkaido, Japan. Fine-grained quartz (4 to 11μm) was chosen as the dosimeter, and a single-aliquot regenerative-dose protocol was used for the determination of equivalent dose (De), with stimulation by both infrared and blue light. The suitability of the measurement procedure was confirmed using dose recovery tests. A high resolution record (˜2 OSL ages/m) identified clear sedimentation rate changes down the core. The OSL ages are significantly dependent on the water content model chosen; two alternative interpretations are discussed, and the geologically preferred model identified. However, ages resulting from the observed (non-modeled) water content lie closest to the available radiocarbon ages (in the range back to 20 ka). Our OSL ages confirm the known high sedimentation rates in this locality, and for the first time demonstrate clear differences in sedimentation rate before, during and after deglaciation. Although the apparent accuracy of single sample ages is not always consistent with expectations, average ages are accurate, and our data show that OSL dating can be a powerful method for establishing high resolution marine chronologies.

  11. Testing portable luminescence reader signals against late Pleistocene to modern OSL ages of coastal and desert dunefield sand in Israel

    NASA Astrophysics Data System (ADS)

    Roskin, Joel; Sivan, Dorit; Bookman, Revital; Porat, Naomi; López, Gloria I.

    2017-04-01

    Rapid assessment of luminescence signals of poly-mineral samples by a pulsed-photon portable OSL reader (PPSL) is useful for interpreting sedimentary sections during fieldwork, and can assist with targeted field sampling for later full OSL dating and prioritize laboratory work. This study investigates PPSL signal intensities in order to assess its usefulness in obtaining relative OSL ages from linear regressions created by interpolating newly generated PPSL values of samples with existing OSL ages from two extensive Nilotic-sourced dunefields. Eighteen OSL-dated sand samples from two quartz-dominated sand systems in Israel were studied:(1) the Mediterranean littoral-sourced coastal dunefields that formed since the middle Holocene; and (2) the inland north-western Negev desert dunefield that rapidly formed between the Last Glacial Maximum and the Holocene. Samples from three coastal dune profiles were also measured. Results show that the PPSL signals differ by several orders of magnitude between modern and late Pleistocene sediments. The coastal and desert sand have different OSL age - PPSL signal ratios. Coastal sand show better correlations between PPSL values and OSL ages. However, using regression curves for each dunefield to interpolate ages is less useful than expected as samples with different ages exhibit similar PPSL signals. The coastal dune profiles yielded low luminescence signal values depicting a modern profile chronology. This study demonstrates that a rapid assessment of the relative OSL ages across different and extensive dunefields is useful and may be achieved. However, the OSL ages obtained by linear regression are only a very rough age estimate. The reasons for not obtaining more reliable ages need to be better understood, as several variables can affect the PPSL signal such as mineral provenance, intrinsic grain properties, micro-dosimetry and moisture content.

  12. Multichannel dosemeter and Al2O3:C optically stimulated luminescence fibre sensors for use in radiation therapy: evaluation with electron beams.

    PubMed

    Magne, S; Auger, L; Bordy, J M; de Carlan, L; Isambert, A; Bridier, A; Ferdinand, P; Barthe, J

    2008-01-01

    This article proposes an innovative multichannel optically stimulated luminescence (OSL) dosemeter for on-line in vivo dose verification in radiation therapy. OSL fibre sensors incorporating small Al(2)O(3):C fibre crystals (TLD(500)) have been tested with an X-ray generator. A reproducible readout procedure should reduce the fading-induced uncertainty ( approximately - 1% per decade). OSL readouts are temperature-dependent [ approximately 0.3% K(-1) when OSL stimulation is performed at the same temperature as irradiation; approximately 0.16% K(-1) after thermalisation (20 degrees C)]. Sensor calibration and depth-dose measurements with electron beams have been performed with a Saturne 43 linear accelerator in reference conditions at CEA-LNHB (ionising radiation reference laboratory in France). Predosed OSL sensors show a good repeatability in multichannel operation and independence versus electron energy in the range (9, 18 MeV). The difference between absorbed doses measured by OSL and an ionisation chamber were within +/-0.9% (for a dose of about 1 Gy) despite a sublinear calibration curve.

  13. Photoluminescence and Optically Stimulated Luminescence Studies of LiAlO2 and LiGaO2 Crystals

    DTIC Science & Technology

    2015-03-26

    tests from the past. In terms of personal dosimetry, OSL dosimeters could potentially replace ther- moluminescence dosimeters (TLDs) which are widely...used by individuals conducting research and maintaining nuclear weapons ( OSL dosimeters are a promising alterna- tive to TLDs because they do not...because they contain lithium, unlike Al2O3:C, the most commonly used OSL dosimeter [2]. The large neutron 1 cross section of lithium-6 makes enriched

  14. Emergency EPR and OSL dosimetry with table vitamins and minerals.

    PubMed

    Sholom, S; McKeever, S W S

    2016-12-01

    Several table vitamins, minerals and L-lysine amino acid have been preliminarily tested as potential emergency dosemeters using electron paramagnetic resonance (EPR) and optically stimulated luminescence (OSL) techniques. Radiation-induced EPR signals were detected in samples of vitamin B2 and L-lysine while samples of multivitamins of different brands as well as mineral Mg demonstrated prominent OSL signals after exposure to ionizing radiation doses. Basic dosimetric properties of the radiation-sensitive substances were studied, namely dose response, fading of the EPR or OSL signals and values of minimum measurable doses (MMDs). For EPR-sensitive samples, the EPR signal is converted into units of dose using a linear dose response and correcting for fading using the measured fading dependence. For OSL-sensitive materials, a multi-aliquot, enhanced-temperature protocol was developed to avoid the problem of sample sensitization and to minimize the influence of signal fading. The sample dose in this case is also evaluated using the dose response and fading curves. MMDs of the EPR-sensitive samples were below 2 Gy while those of the OSL-sensitive materials were below 500 mGy as long as the samples are analyzed within 1 week after exposure. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. TL-OSL correlation studies of LiMgPO4:Tb,B dosimetric phosphor

    NASA Astrophysics Data System (ADS)

    Singh, A. K.; Menon, S. N.; Dhabekar, Bhushan; Kadam, Sonal; Chougaonkar, M. P.; Mayya, Y. S.

    2012-03-01

    The recently synthesized LiMgPO4:Tb,B (LMP) is a highly sensitive Optically Stimulated Luminescence (OSL) phosphor for dosimetric applications. Studies were carried out to assess the correlation between thermoluminescence (TL) and OSL of this phosphor. Measurements like Residual TL (R-TL), Continuous Wave OSL (CW-OSL) and Linearly Modulated OSL (LM-OSL) of LMP were carried out and various curves thus obtained were de-convolved using Computerized Curve Deconvolution (CCD) program. The deconvolution of CW-OSL and LM-OSL curves showed five different first order components in LMP. It was observed that OSL signal of LMP has its origin from five traps having different photo-ionization cross-sections. Same traps were found to be responsible for both TL and OSL in this phosphor. Bleaching decay rates were calculated for each R-TL glow peaks and compared with the decay rates of individual OSL components. The value of decay rates of R-TL and OSL matches well. Experimental verification of presence of individual OSL components using tbleach-tmax method was carried out.

  16. A short-time fading study of Al2O3:C

    NASA Astrophysics Data System (ADS)

    Nascimento, L. F.; Vanhavere, F.; Silva, E. H.; Deene, Y. De

    2015-01-01

    This paper studies the short-time fading from Al2O3:C by measuring optically stimulated luminescence (OSL) signals (Total OSL: TOSL, and Peak OSL: POSL) from droplets and Luxel™ pellets. The influence of various bleaching regimes (blue, green and white) and light power is compared. The fading effect is the decay of the OSL signal in the dark at room temperature. Al2O3:C detectors were submitted to various bleaching regimes, irradiated with a reference dose and read out after different time spans. Investigations were carried out using 2 mm size droplet detectors, made of thin Al2O3:C powder mixed with a photocured polymer. Tests were compared to Luxel™-type detectors (Landauer Inc.). Short-time post-irradiation fading is present in OSL results (TOSL and POSL) droplets for time spans up to 200 s. The effect of short-time fading can be lowered/removed when treating the detectors with high-power and/or long time bleaching regimes; this result was observed in both TOSL and POSL from droplets and Luxel™.

  17. Optically stimulated luminescence (OSL) dosimetry in medicine.

    PubMed

    Yukihara, E G; McKeever, S W S

    2008-10-21

    This paper reviews fundamental and practical aspects of optically stimulated luminescence (OSL) dosimetry pertaining to applications in medicine, having particularly in mind new researchers and medical physicists interested in gaining familiarity with the field. A basic phenomenological model for OSL is presented and the key processes affecting the outcome of an OSL measurement are discussed. Practical aspects discussed include stimulation modalities (continuous-wave OSL, pulsed OSL and linear modulation OSL), basic experimental setup, available OSL readers, optical fiber systems and basic properties of available OSL dosimeters. Finally, results from the recent literature on applications of OSL in radiotherapy, radiodiagnostics and heavy charged particle dosimetry are discussed in light of the theoretical and practical framework presented in this review. Open questions and future challenges in OSL dosimetry are highlighted as a guide to the research needed to further advance the field.

  18. Dosimetry of Al2O3 optically stimulated luminescent dosimeter at high energy photons and electrons

    NASA Astrophysics Data System (ADS)

    Yusof, M. F. Mohd; Joohari, N. A.; Abdullah, R.; Shukor, N. S. Abd; Kadir, A. B. Abd; Isa, N. Mohd

    2018-01-01

    The linearity of Al2O3 OSL dosimeters (OSLD) were evaluated for dosimetry works in clinical photons and electrons. The measurements were made at a reference depth of Zref according to IAEA TRS 398:2000 codes of practice at 6 and 10 MV photons and 6 and 9 MeV electrons. The measured dose was compared to the thermoluminescence dosimeters (TLD) and ionization chamber commonly used for dosimetry works for higher energy photons and electrons. The results showed that the measured dose in OSL dosimeters were in good agreement with the reported by the ionization chamber in both high energy photons and electrons. A reproducibility test also reported excellent consistency of readings with the OSL at similar energy levels. The overall results confirmed the suitability of OSL dosimeters for dosimetry works involving high energy photons and electrons in radiotherapy.

  19. OSL and thermally assisted OSL response in dental enamel for its possible application in retrospective dosimetry.

    PubMed

    Soni, Anuj; Mishra, D R; Polymeris, G S; Bhatt, B C; Kulkarni, M S

    2014-11-01

    Dental enamel was studied for its thermoluminescence (TL) and optically stimulated luminescence (OSL) defects. The TL studies showed a wide glow curve with multiple peaks. The thermally assisted OSL (TA-OSL) studies showed that the integrated TA-OSL and thus OSL signal increases with readout temperature between 100 and 250 °C, due to the temperature dependence of OSL. The thermally assisted energy E A associated with this increase is found to be 0.21 ± 0.015 eV. On the other hand, the signal intensity decreases with temperature between 260 and 450 °C. This decrease could be due to depletion of OSL active traps or possible thermal quenching. The increase of the OSL signal at increased temperature can be used to enhance the sensitivity of dental enamel for ex vivo measurements in retrospective dosimetry. The emission and excitation spectra of its luminescence centers were studied by photoluminescence and were found to be at 412 and 324 nm, respectively. It was found to possess multiple OSL active traps having closely lying photoionization cross sections characterized by continuous wave OSL and nonlinear OSL methods. The investigated dental enamel samples showed a linear OSL dose response up to 500 Gy. The dose threshold was found to be 100 mGy using a highly sensitive compact OSL reader with blue LED (470 nm) stimulation.

  20. An Optically Stimulated Luminescence Uranium Enrichment Monitor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Steven D.; Tanner, Jennifer E.; Simmons, Kevin L.

    The Pacific Northwest National Laboratory (PNNL) has pioneered the use of Optically Stimulated Luminescence (OSL) technology for use in personnel dosimetry and high dose radiation processing dosimetry. PNNL has developed and patented an alumina-based OSL dosimeter that is being used by the majority of medical X-ray and imaging technicians worldwide. PNNL has conceived of using OSL technology to passively measure the level of UF6 enrichment by attaching the prototype OSL monitor to pipes containing UF6 gas within an enrichment facility. The prototype OSL UF6 monitor utilizes a two-element approach with the first element open and unfiltered to measure both themore » low energy and high energy gammas from the UF6, while the second element utilizes a 3-mm thick tungsten filter to eliminate the low energy gammas and pass only the high energy gammas from the UF6. By placing a control monitor in the room away from the UF6 pipes and other ionizing radiation sources, the control readings can be subtracted from the UF6 pipe monitor measurements. The ratio of the shielded to the unshielded net measurements provides a means to estimate the level of uranium enrichment. PNNL has replaced the commercially available MicroStar alumina-based dosimeter elements with a composite of polyethylene plastic, high-Z glass powder, and BaFBr:Eu OSL phosphor powder at various concentrations. The high-Z glass was added in an attempt to raise the average “Z” of the composite dosimeter and increase the response. Additionally, since BaFBr:Eu OSL phosphor is optimally excited and emits light at different wavelengths compared to alumina, the commercially available MicroStar reader was modified for reading BaFBr:Eu in a parallel effort to increase reader sensitivity. PNNL will present the design and performance of our novel OSL uranium enrichment monitor based on a combination of laboratory and UF6 test loop measurements. PNNL will also report on the optimization effort to achieve the highest possible performance from both the OSL enrichment monitor and the new custom OSL reader modified for this application. This project has been supported by the US Department of Energy’s National Nuclear Security Administration’s Office of Dismantlement and Transparency (DOE/NNSA/NA-241).« less

  1. Component resolved bleaching study in natural calcium fluoride using CW-OSL, LM-OSL and residual TL glow curves after bleaching.

    PubMed

    Angeli, Vasiliki; Polymeris, George S; Sfampa, Ioanna K; Tsirliganis, Nestor C; Kitis, George

    2017-04-01

    Natural calcium fluoride has been commonly used as thermoluminescence (TL) dosimeter due to its high luminescence intensity. The aim of this work includes attempting a correlation between specific TL glow curves after bleaching and components of linearly modulated optically stimulated luminescence (LM-OSL) as well as continuous wave OSL (CW-OSL). A component resolved analysis was applied to both integrated intensity of the RTL glow curves and all OSL decay curves, by using a Computerized Glow-Curve De-convolution (CGCD) procedure. All CW-OSL and LM-OSL components are correlated to the decay components of the integrated RTL signal, apart from two RTL components which cannot be directly correlated with either LM-OSL or CW-OSL component. The unique, stringent criterion for this correlation deals with the value of the decay constant λ of each bleaching component. There is only one, unique bleaching component present in all three luminescence entities which were the subject of the present study, indicating that each TL trap yields at least three different bleaching components; different TL traps can indicate bleaching components with similar values. According to the data of the present work each RTL bleaching component receives electrons from at least two peaks. The results of the present study strongly suggest that the traps that contribute to TL and OSL are the same. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Setting Age Limits for TT-OSL Dating - the Local Effect

    NASA Astrophysics Data System (ADS)

    Faershtein, G.; Porat, N.; Guralnik, B.; Matmon, A.

    2017-12-01

    Luminescence dating techniques, especially Optically Stimulated Luminescence (OSL) on quartz, are widely used for dating middle Pleistocene to late Holocene sediments from different geological settings. The dating limit of a particular luminescence method depends on signal saturation and its thermal stability. The OSL signal saturates at doses of 200 Gy, equivalent to ages of 150-300 ka. Thermally Transferred OSL (TT-OSL) is a developmental technique, which potentially extends the luminescence dating range up to 1000 ka. For the Chinese Loess Plateau, experiments have shown that the natural TT-OSL signal saturates at 2200 Gy (Chapot et al., 2016). Regarding thermal stability, different studies report a wide range of estimates (0.24-861 Ma), suggesting that the thermal lifetime of TT-OSL is (i) currently poorly constrained, and (ii) may vary both by sample and region. Here, we investigated the dating limit of TT-OSL, using quartz of Nilotic origin (Israel), obtained from two sediment sections of similar depth but different dose rates. Natural dose response curves (DRC) of the TT-OSL signal were constructed for each section separately. In both sections, luminescence intensity grows sub-linearly up to 450 Gy, beyond which it remains constant with depth. The absence of equivalent doses (De) over 600 Gy, at both sections (as well as elsewhere regionally), suggest that TT-OSL signal saturation may be an intrinsic property, related to quartz provenance, and independent of the specific ionizing dose rate at each section. The thermal stability of TT-OSL was investigated on a modern sample from one section, using a combination of analytical techniques (varying heating rates, and isothermal storage). The obtained TT-OSL lifetimes range between 105-107 ka, and reinforce a significant inter sample variability. A synthesis of our results suggests that TT-OSL ages of Nilotic quartz derived from De values over 450 Gy, are likely underestimates, and should be treated as minimum ages. The limiting value of 600 Gy for local quartz TT-OSL is likely representative of a steady-state between TT-OSL trap filling due to ionizing radiation, and the concurrent thermal empting of these traps.

  3. Development of europium doped BaSO4 TL OSL dual phosphor for radiation dosimetry applications

    NASA Astrophysics Data System (ADS)

    Patle, Anita; Patil, R. R.; Kulkarni, M. S.; Bhatt, B. C.; Moharil, S. V.

    2015-08-01

    This paper presents the results on the preparation and characterization of Europium-doped Barium sulfate (BaSO4: Eu) TL /OSL dual phosphor. The OSL sensitivity was found to be 11% of the commercially available Al2O3: C, using area integration method. The sample also shows good TL sensitivity and the dosimetric peak appears around 190°C with a shoulder at 282°C. After OSL readout, No change in the TL glow curve is observed. Since the observed TL peaks are not responsible for the observed OSL, good OSL as well as TL sensitivity and low fading will make this phosphor suitable for applications in radiation dosimetry using OSL as well as TL.

  4. Multichannel Dosimeter and α-Al2O3:C Optically Stimulated Luminescence (OSL) Fiber Sensors for Use in Radiation Therapy—Evaluation With Photon Beams

    NASA Astrophysics Data System (ADS)

    Magne, Sylvian; de Carlan, Loïc; Bordy, Jean-Marc; Isambert, Aurélie; Bridier, André; Ferdinand, Pierre

    2011-04-01

    A multichannel OSL fiber optic dosimeter based on optically stimulated luminescence (OSL) of alumina is proposed for online in vivo dosimetry (IVD) in radiation therapy (RT). Two types of dosimetric-grade Al2O3:C crystals are compared and show different behavior according to manufacturing process. Metrological validations have been performed with a Saturne 43 LINAC in reference conditions at CEA LIST LNHB (French Ionizing Radiation Reference Laboratory). The dose response of OSL integrals under photon beam irradiation (6, 12, and 20 MV) show sublinearity behavior modeled by second-order equations and exhibit a small energy dependence (between 0.7% and 1.4%), explained by a modified intermediate cavity model adapted to a LINAC photon spectrum. Preclinical tests at Institut Gustave Roussy (IGR) prove that a proper design for a PMMA build-up cap leads to a low dependence vs photon beam orientation (± 1.5% and ± 0.9%) and vs field size in view of surface measurements.

  5. Emergency OSL/TL dosimetry with integrated circuits from mobile phones

    NASA Astrophysics Data System (ADS)

    Sholom, S.; McKeever, S. W. S.

    2014-09-01

    Integrated circuits (ICs) from several mobile phones were studied as possible emergency dosimeters using optically stimulated luminescence (OSL) and thermoluminescence (TL) techniques. Measurement protocols were developed for ICs that take into consideration the effect of sensitization of the samples with increasing dose as well as fading of the signals after sample exposure. It was found that the OSL technique has a higher sensitivity with ICs when compared to TL, while the TL signals were characterized by better stability with time after exposure. Values of minimum measurable doses were found to be in the range between a few tens of mGy and several tens of mGy for the tested samples. It was concluded that ICs from mobile phones could be used for emergency dose reconstruction.

  6. SU-E-T-75: Commissioning Optically Stimulated Luminescence Dosimeters for Fast Neutron Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, L; Yang, F; Sandison, G

    Purpose: Fast neutrons therapy used at the University of Washington is clinically proven to be more effective than photon therapy in treating salivary gland and other cancers. A nanodot optically stimulated luminescence (OSL) system was chosen to be commissioned for patient in vivo dosimetry for neutron therapy. The OSL-based radiation detectors are not susceptible to radiation damage caused by neutrons compared to diodes or MOSFET systems. Methods: An In-Light microStar OSL system was commissioned for in vivo use by radiating Landauer nanodots with neutrons generated from 50.0 MeV protons accelerated onto a beryllium target. The OSLs were calibrated the depthmore » of maximum dose in solid water localized to 150 cm SAD isocenter in a 10.3 cm square field. Linearity was tested over a typical clinical dose fractionation range i.e. 0 to 150 neutron-cGy. Correction factors for transient signal fading, trap depletion, gantry angle, field size, and wedge factor dependencies were also evaluated. The OSLs were photo-bleached between radiations using a tungsten-halogen lamp. Results: Landauer sensitivity factors published for each nanodot are valid for measuring photon and electron doses but do not apply for neutron irradiation. Individually calculated nanodot calibration factors exhibited a 2–5% improvement over calibration factors computed by the microStar InLight software. Transient fading effects had a significant impact on neutron dose reading accuracy compared to photon and electron in vivo dosimetry. Greater accuracy can be achieved by calibrating and reading each dosimeter within 1–2 hours after irradiation. No additional OSL correction factors were needed for field size, gantry angle, or wedge factors in solid water phantom measurements. Conclusion: OSL detectors are a useful for neutron beam in vivo dosimetry verification. Dosimetric accuracy comparable to conventional diode systems can be achieved. Accounting for transient fading effects during the neutron beam calibration is a critical component for achieving comparable accuracy.« less

  7. Emergency Optically Stimulated Luminescence Dosimetry Using Different Materials

    PubMed Central

    Sholom, S; DeWitt, R; Simon, SL; Bouville, A; McKeever, SWS

    2011-01-01

    Several materials were tested as possible individual emergency dosimeters using Optically Stimulated Luminescence (OSL) as means to assess the exposure. Materials investigated included human nails, business cards and plastic buttons. The OSL properties of these materials were studied in comparison with those of teeth. Most samples revealed OSL signals only after exposure to ionizing radiation; some samples of business cards, however, displayed a strong initial “native” signal (i.e. existing in the samples prior to irradiation). The sensitivity (minimum measurable dose) of the samples was found to vary significantly from sample to sample of the same material and was in the range from several tens of mGy to a few dozens of Gy. The dose response curves were linear for doses below 10 Gy. Fading of the OSL signals was estimated for different lenghts of times and found to be ~95%, 45%, 30% and 15% for samples of teeth, business cards, buttons and nails, respectively, following storage at room temperature in the dark for a period of 3 weeks after exposure. For samples stored under routine laboratory light, fading was much faster and the radiation-induced signals almost disappeared after a few hours of such illumination. It was concluded that the tested materials could be used in triage situations to detect and estimate the possible overexposure of individuals if the measurements can be performed soon enough after exposure. PMID:22125409

  8. Emergency Optically Stimulated Luminescence Dosimetry Using Different Materials.

    PubMed

    Sholom, S; Dewitt, R; Simon, Sl; Bouville, A; McKeever, Sws

    2011-12-01

    Several materials were tested as possible individual emergency dosimeters using Optically Stimulated Luminescence (OSL) as means to assess the exposure. Materials investigated included human nails, business cards and plastic buttons. The OSL properties of these materials were studied in comparison with those of teeth. Most samples revealed OSL signals only after exposure to ionizing radiation; some samples of business cards, however, displayed a strong initial "native" signal (i.e. existing in the samples prior to irradiation). The sensitivity (minimum measurable dose) of the samples was found to vary significantly from sample to sample of the same material and was in the range from several tens of mGy to a few dozens of Gy. The dose response curves were linear for doses below 10 Gy. Fading of the OSL signals was estimated for different lenghts of times and found to be ~95%, 45%, 30% and 15% for samples of teeth, business cards, buttons and nails, respectively, following storage at room temperature in the dark for a period of 3 weeks after exposure. For samples stored under routine laboratory light, fading was much faster and the radiation-induced signals almost disappeared after a few hours of such illumination. It was concluded that the tested materials could be used in triage situations to detect and estimate the possible overexposure of individuals if the measurements can be performed soon enough after exposure.

  9. Development of europium doped BaSO{sub 4} TL OSL dual phosphor for radiation dosimetry applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patle, Anita, E-mail: patle.anita25@gmail.com; Patil, R. R.; Kulkarni, M. S.

    This paper presents the results on the preparation and characterization of Europium-doped Barium sulfate (BaSO{sub 4}: Eu) TL /OSL dual phosphor. The OSL sensitivity was found to be 11% of the commercially available Al{sub 2}O{sub 3}: C, using area integration method. The sample also shows good TL sensitivity and the dosimetric peak appears around 190°C with a shoulder at 282°C. After OSL readout, No change in the TL glow curve is observed. Since the observed TL peaks are not responsible for the observed OSL, good OSL as well as TL sensitivity and low fading will make this phosphor suitable formore » applications in radiation dosimetry using OSL as well as TL.« less

  10. Luminescence and Radiocarbon dating of roman time harbour sediments from Cologne - A comparison of different methods

    NASA Astrophysics Data System (ADS)

    Lauer, Tobias; Frechen, Manfred; Fuchs, Magret C.; Trier, Marcus; Tsukamoto, Sumiko

    2010-05-01

    Optically stimulated luminescence (OSL) dating was applied to fluvial and colluvial deposits which were taken from a roman time harbour basin in Cologne. Hence, independent age control was given by roman artefacts (coins, bricks) of known age and by three radiocarbon data. For one sample (well sorted fluvial sand), a single aliquot regenerative (SAR) protocol was applied to coarse grain quartz. A large number of equivalent doses (80) were collected and after De-measurements, different statistical approaches were tested. The results show, that calculating the age by using the Mean or Median of all accepted De-values yields OSL ages of 3.5 ± 0.3 ka and 2.8 ± 0.3 ka, respectively, what would be significantly too old. The application of the Leading Edge Method (Lepper & McKeever 2002), the statistical approach after Fuchs & Lang (2001) or the Minimum Age Method (MAM3) after Galbraith et al. (1999) yield OSL age estimates of 2.0 ± 0.1 ka, 2.1 ± 0.1 ka and 1.7 ± 0.6 ka, respectively. Those ages fit very well to the 14C-ages and are in better agreement with the known archaeological background. For the colluvial sample, the quartz OSL signal was effected by feldspar impurities. For this sample, different methodological approaches were tested to see which one has the best potential to minimize the feldspar contribution. Therefore the post-IR blue stimulated quartz luminescence was recorded. The quartz signal was measured using continuous wave (CW) and pulsed OSL (POSL). For the CW measurements, it was tested if a prior IR-bleach @ 50°C or @ 225°C has better potential for minimizing the feldspar signal. In this case, an IR-bleach @ 225°C (Buylaert et al. in press) was the most effective way to obtain a higher purity of the quartz OSL signal. Buylaert, J.P., Murray, A.S., Thomsen, K.J., Jain, M.: The effect of preheating on the IRSL signal from feldspar. In press. - Radiat. Meas., special issue, LED08. Fuchs, M. & Lang, A. (2001): OSL dating of coarse-grain fluvial quartz using single-aliquot protocols on sediments from NE Peloponnese, Greece. - Quaternary Science Reviews, 20: 783-787. Galbraith, R. F., Roberts, R. G., Laslett, G. M., Yoshida, H. & Olley, J. M. (1999): Optical dating of single and multiple grains of quartz from Jinmium Rock Shelter, northern Australia: Part 1, experimental design and statistical models. - Archaeometry, 41: 339-364. Lepper, K. & McKeever, S.W.S. (2002): An objective methodology for dose distribution analysis. Radiation Protection Dosimetry. - Solid State Dosimetry, 101: 349-352.

  11. Experimental features of natural thermally assisted OSL (NTA-OSL) signal in various quartz samples; preliminary results

    NASA Astrophysics Data System (ADS)

    Polymeris, George S.; Şahiner, Eren; Meriç, Niyazi; Kitis, George

    2015-04-01

    The access to the OSL signals from very deep traps is achieved by an alternative experimental method which comprises combined action of thermal and optical stimulation, termed as thermally assisted OSL (TA-OSL). This experimental technique was suggested in order to not only measure the signal of the deep traps without heating the sample to temperatures greater than 500 °C, but also use the former for dosimetry purposes as well, due to exhibiting a number of interesting properties which could be effectively used towards dosimetry purposes, especially for large accumulated artificial doses. The present study provides for the first time in the literature with preliminary results towards the feasibility study of the naturally occurring TA-OSL signal in coarse grains of natural quartz towards its effective application to geological dating. The samples subjected to the present study were collected from fault lines in Kütahya-Simav, Western Anatolia Region, Turkey; independent luminescence approaches yielded an equivalent dose larger than 100 Gy. Several experimental luminescence features were studied, such as sensitivity, reproducibility, TA-OSL curve shape as well as the correlation between NTA-OSL and NTL/NOSL. Nevertheless, special emphasis was addressed towards optimizing the measuring conditions of the TA-OSL signal. The high intensity of the OSL signal confirms the existence of a transfer phenomenon from deep electron traps. The increase of the integrated TA-OSL signal as a function of temperature is monitored for temperatures up to 180 °C, indicating the later as the most effective stimulation temperature. At all temperatures of the studied temperature range between 75 and 260 °C, the shape of the signal resembles much the shape of a typical CW-OSL curve. However, a long-lived, residual NTA-OSL component was monitored after the primary, initial NTA-OSL measured at 180 °C; the intensity of this component increases with increasing stimulation temperature. The prevalence of these luminescent features was investigated, while the implications on dating applications of these features were also discussed.

  12. Deconvolution Method on OSL Curves from ZrO2 Irradiated by Beta and UV Radiations

    NASA Astrophysics Data System (ADS)

    Rivera, T.; Kitis, G.; Azorín, J.; Furetta, C.

    This paper reports the optically stimulated luminescent (OSL) response of ZrO2 to beta and ultraviolet radiations in order to investigate the potential use of this material as a radiation dosimeter. The experimentally obtained OSL decay curves were analyzed using the computerized curve de-convolution (CCD) method. It was found that the OSL curve structure, for the short (practical) illumination time used, consists of three first order components. The individual OSL dose response behavior of each component was found. The values of the time at the OSL peak maximum and the decay constant of each component were also estimated.

  13. An Interlaboratory Comparison of Dosimetry for a Multi-institutional Radiobiological

    PubMed Central

    Seed, TM; Xiao, S; Manley, N; Nikolich-Zugich, J; Pugh, J; van den Brink, M; Hirabayashi, Y; Yasutomo, K; Iwama, A; Koyasu, S; Shterev, I; Sempowski, G; Macchiarini, F; Nakachi, K; Kunugi, KC; Hammer, CG; DeWerd, LA

    2016-01-01

    Purpose An interlaboratory comparison of radiation dosimetry was conducted to determine the accuracy of doses being used experimentally for animal exposures within a large multi-institutional research project. The background and approach to this effort are described and discussed in terms of basic findings, problems and solutions. Methods Dosimetry tests were carried out utilizing optically stimulated luminescence (OSL) dosimeters embedded midline into mouse carcasses and thermal luminescence dosimeters (TLD) embedded midline into acrylic phantoms. Results The effort demonstrated that the majority (4/7) of the laboratories was able to deliver sufficiently accurate exposures having maximum dosing errors of ≤ 5%. Comparable rates of ‘dosimetric compliance’ were noted between OSL- and TLD-based tests. Data analysis showed a highly linear relationship between ‘measured’ and ‘target’ doses, with errors falling largely between 0–20%. Outliers were most notable for OSL-based tests, while multiple tests by ‘non-compliant’ laboratories using orthovoltage x-rays contributed heavily to the wide variation in dosing errors. Conclusions For the dosimetrically non-compliant laboratories, the relatively high rates of dosing errors were problematic, potentially compromising the quality of ongoing radiobiological research. This dosimetry effort proved to be instructive in establishing rigorous reviews of basic dosimetry protocols ensuring that dosing errors were minimized. PMID:26857121

  14. An interlaboratory comparison of dosimetry for a multi-institutional radiobiological research project: Observations, problems, solutions and lessons learned.

    PubMed

    Seed, Thomas M; Xiao, Shiyun; Manley, Nancy; Nikolich-Zugich, Janko; Pugh, Jason; Van den Brink, Marcel; Hirabayashi, Yoko; Yasutomo, Koji; Iwama, Atsushi; Koyasu, Shigeo; Shterev, Ivo; Sempowski, Gregory; Macchiarini, Francesca; Nakachi, Kei; Kunugi, Keith C; Hammer, Clifford G; Dewerd, Lawrence A

    2016-01-01

    An interlaboratory comparison of radiation dosimetry was conducted to determine the accuracy of doses being used experimentally for animal exposures within a large multi-institutional research project. The background and approach to this effort are described and discussed in terms of basic findings, problems and solutions. Dosimetry tests were carried out utilizing optically stimulated luminescence (OSL) dosimeters embedded midline into mouse carcasses and thermal luminescence dosimeters (TLD) embedded midline into acrylic phantoms. The effort demonstrated that the majority (4/7) of the laboratories was able to deliver sufficiently accurate exposures having maximum dosing errors of ≤5%. Comparable rates of 'dosimetric compliance' were noted between OSL- and TLD-based tests. Data analysis showed a highly linear relationship between 'measured' and 'target' doses, with errors falling largely between 0 and 20%. Outliers were most notable for OSL-based tests, while multiple tests by 'non-compliant' laboratories using orthovoltage X-rays contributed heavily to the wide variation in dosing errors. For the dosimetrically non-compliant laboratories, the relatively high rates of dosing errors were problematic, potentially compromising the quality of ongoing radiobiological research. This dosimetry effort proved to be instructive in establishing rigorous reviews of basic dosimetry protocols ensuring that dosing errors were minimized.

  15. Apparatus And Method For Osl-Based, Remote Radiation Monitoring And Spectrometry

    DOEpatents

    Miller, Steven D.; Smith, Leon Eric; Skorpik, James R.

    2006-03-07

    Compact, OSL-based devices for long-term, unattended radiation detection and spectroscopy are provided. In addition, a method for extracting spectroscopic information from these devices is taught. The devices can comprise OSL pixels and at least one radiation filter surrounding at least a portion of the OSL pixels. The filter can modulate an incident radiation flux. The devices can further comprise a light source and a detector, both proximally located to the OSL pixels, as well as a power source and a wireless communication device, each operably connected to the light source and the detector. Power consumption of the device ranges from ultra-low to zero. The OSL pixels can retain data regarding incident radiation events as trapped charges. The data can be extracted wirelessly or manually. The method for extracting spectroscopic data comprises optically stimulating the exposed OSL pixels, detecting a readout luminescence, and reconstructing an incident-energy spectrum from the luminescence.

  16. Apparatus and method for OSL-based, remote radiation monitoring and spectrometry

    DOEpatents

    Smith, Leon Eric [Richland, WA; Miller, Steven D [Richland, WA; Bowyer, Theodore W [Oakton, VA

    2008-05-20

    Compact, OSL-based devices for long-term, unattended radiation detection and spectroscopy are provided. In addition, a method for extracting spectroscopic information from these devices is taught. The devices can comprise OSL pixels and at least one radiation filter surrounding at least a portion of the OSL pixels. The filter can modulate an incident radiation flux. The devices can further comprise a light source and a detector, both proximally located to the OSL pixels, as well as a power source and a wireless communication device, each operably connected to the light source and the detector. Power consumption of the device ranges from ultra-low to zero. The OSL pixels can retain data regarding incident radiation events as trapped charges. The data can be extracted wirelessly or manually. The method for extracting spectroscopic data comprises optically stimulating the exposed OSL pixels, detecting a readout luminescence, and reconstructing an incident-energy spectrum from the luminescence.

  17. Pure thermal sensitisation and pre-dose effect of OSL in both unfired and annealed quartz samples

    NASA Astrophysics Data System (ADS)

    Oniya, Ebenezer O.; Polymeris, George S.; Jibiri, Nnamdi N.; Tsirliganis, Nestor C.; Babalola, Israel A.; Kitis, George

    2017-06-01

    The sensitisation of quartz has attracted much attention since its thorough understanding is important in luminescence studies and dating applications. The present investigation examines the influence of pure thermal activation and predose treatments on the sensitisation of different components of linearly modulated optically stimulated luminescence (LM-OSL) measured at room temperature (RT) thereby eliminating undesired thermal quenching effects. Annealed and unfired quartz samples from Nigeria were used. The OSL measurements were carried out using an automated RISØTL/OSL reader (model-TL/OSL-DA-15). A new approach was adopted to match each of the resolved components of the RT-LM-OSL to respective thermoluminescence (TL) peaks that share the same electron trap and recombination centers. Pure thermal activation and pre-dose treatments respectively affect the sensitisation of all the components of the RT-LM-OSL in a similar manner as the one reported for the 110 °C TL peak but without thermal quenching contributions. Component C4 in annealed samples that was identified to share the same electron trap and recombination centers with the 110 °C TL peak was also proved appropriate for RT-LM-OSL, instead of the initial part of the continuous wave (CW) OSL signal, thus the methods can serve as complementary dating methods.

  18. Optically stimulated luminescence in vivo dosimetry for radiotherapy: physical characterization and clinical measurements in (60)Co beams.

    PubMed

    Mrčela, I; Bokulić, T; Izewska, J; Budanec, M; Fröbe, A; Kusić, Z

    2011-09-21

    A commercial optically stimulated luminescence (OSL) dosimetry system was investigated for in vivo dosimetry in radiation therapy. Dosimetric characteristics of InLight dot dosimeters and a microStar reader (Landauer Inc.) were tested in (60)Co beams. The reading uncertainty of a single dosimeter was 0.6%. The reproducibility of a set of dosimeters after a single irradiation was 1.6%, while in repeated irradiations of the same dosimeters it was found to be 3.5%. When OSL dosimeters were optically bleached between exposures, the reproducibility of repeated measurements improved to 1.0%. Dosimeters were calibrated for the entrance dose measurements and a full set of correction factors was determined. A pilot patient study that followed phantom validation testing included more than 100 measured fields with a mean relative difference of the measured entrance dose from the expected dose of 0.8% and the standard deviation of 2.5%. In conclusion, these results demonstrate that OSL dot dosimeters represent a valid alternative to already established in vivo dosimetry systems.

  19. Optically stimulated luminescence in vivo dosimetry for radiotherapy: physical characterization and clinical measurements in 60Co beams

    NASA Astrophysics Data System (ADS)

    Mrčela, I.; Bokulić, T.; Izewska, J.; Budanec, M.; Fröbe, A.; Kusić, Z.

    2011-09-01

    A commercial optically stimulated luminescence (OSL) dosimetry system was investigated for in vivo dosimetry in radiation therapy. Dosimetric characteristics of InLight dot dosimeters and a microStar reader (Landauer Inc.) were tested in 60Co beams. The reading uncertainty of a single dosimeter was 0.6%. The reproducibility of a set of dosimeters after a single irradiation was 1.6%, while in repeated irradiations of the same dosimeters it was found to be 3.5%. When OSL dosimeters were optically bleached between exposures, the reproducibility of repeated measurements improved to 1.0%. Dosimeters were calibrated for the entrance dose measurements and a full set of correction factors was determined. A pilot patient study that followed phantom validation testing included more than 100 measured fields with a mean relative difference of the measured entrance dose from the expected dose of 0.8% and the standard deviation of 2.5%. In conclusion, these results demonstrate that OSL dot dosimeters represent a valid alternative to already established in vivo dosimetry systems.

  20. [BeO-OSL detectors for dose measurements in cell cultures].

    PubMed

    Andreeff, M; Sommer, D; Freudenberg, R; Reichelt, U; Henniger, J; Kotzerke, J

    2009-01-01

    The absorbed dose is an important parameter in experiments involving irradiation of cells in vitro with unsealed radionuclides. Typically, this is estimated with a model calculation, although the results thus obtained cannot be verified. Generally used real-time measurement methods are not applicable in this setting. A new detector material with in vitro suitability is the subject of this work. Optically-stimulated luminescence (OSL) dosimeters based on beryllium oxide (BeO) were used for dose measurement in cell cultures exposed to unsealed radionuclides. Their qualitative properties (e. g. energy-dependent count rate sensitivity, fading, contamination by radioactive liquids) were determined and compared to the results of a Monte Carlo simulation (using AMOS software). OSL dosimeters were tested in common cell culture setups with a known geometry. Dose reproducibility of the OSL dosimeters was +/-1.5%. Fading at room temperature was 0.07% per day. Dose loss (optically-stimulated deletion) under ambient lighting conditions was 0.5% per minute. The Monte Carlo simulation for the relative sensitivity at different beta energies provided corresponding results to those obtained with the OSL dosimeters. Dose profile measurements using a 6 well plate and 14 ml PP tube showed that the geometry of the cell culture vessel has a marked influence on dose distribution with 188Re. A new dosimeter system was calibrated with beta-emitters of different energy. It turned out as suitable for measuring dose in liquids. The dose profile measurements obtained are suitably precise to be used as a check against theoretical dose calculations.

  1. Overview of physical dosimetry methods for triage application integrated in the new European network RENEB.

    PubMed

    Trompier, François; Burbidge, Christopher; Bassinet, Céline; Baumann, Marion; Bortolin, Emanuela; De Angelis, Cinzia; Eakins, Jonathan; Della Monaca, Sara; Fattibene, Paola; Quattrini, Maria Cristina; Tanner, Rick; Wieser, Albrecht; Woda, Clemens

    2017-01-01

    In the EC-funded project RENEB (Realizing the European Network in Biodosimetry), physical methods applied to fortuitous dosimetric materials are used to complement biological dosimetry, to increase dose assessment capacity for large-scale radiation/nuclear accidents. This paper describes the work performed to implement Optically Stimulated Luminescence (OSL) and Electron Paramagnetic Resonance (EPR) dosimetry techniques. OSL is applied to electronic components and EPR to touch-screen glass from mobile phones. To implement these new approaches, several blind tests and inter-laboratory comparisons (ILC) were organized for each assay. OSL systems have shown good performances. EPR systems also show good performance in controlled conditions, but ILC have also demonstrated that post-irradiation exposure to sunlight increases the complexity of the EPR signal analysis. Physically-based dosimetry techniques present high capacity, new possibilities for accident dosimetry, especially in the case of large-scale events. Some of the techniques applied can be considered as operational (e.g. OSL on Surface Mounting Devices [SMD]) and provide a large increase of measurement capacity for existing networks. Other techniques and devices currently undergoing validation or development in Europe could lead to considerable increases in the capacity of the RENEB accident dosimetry network.

  2. Procedural revision to the use-dilution methods: establishment of maximum log density value for test microbes on inoculated carriers.

    PubMed

    Tomasino, Stephen F; Pines, Rebecca M; Hamilton, Gordon C

    2012-01-01

    (Staphylococcus aureus) and 964.02 (Pseudomonas aeruginosa), were revised in 2009 to include a standardized procedure to measure the log density of the test microbe and to establish a minimum mean log density value of 6.0 (geometric mean of 1.0 x 10(6) CFU/carrier) to qualify the test results. This report proposes setting a maximum mean log density value of 7.0 (geometric mean of 1.0 x 10(7) CFU/carrier) to further standardize the procedure. The minimum value was based on carrier count data collected by four laboratories over an 8-year period (1999-2006). The data have been updated to include an additional 4 years' worth of data (2006-2010) collected by the same laboratories. A total of 512 tests were conducted on products bearing claims against P. aeruginosa and S. aureus with and without an organic soil load (OSL) added to the inoculum (as specified on the product label claim). Six carriers were assayed in each test, for a total of 3072 carriers. Mean log densities for each of the 512 tests were at least 6.0. With the exception of two tests, one for P. aeruginosa without OSL and one for S. aureus with OSL, the mean log densities did not exceed 7.5 (geometric mean of 3.2 x 10(7) CFU/carrier). Across microbes and OSL treatments, the mean log density (+/- SEM) was 6.80 (+/- 0.07) per carrier (a geometric mean of 6.32 x 10(6) CFUlcarrier) and acceptable repeatability (0.28) and reproducibility (0.31) SDs were exhibited. A maximum mean log density per carrier of 7.0 is being proposed here as a validity requirement for S. aureus and P. aeruginosa. A modification to the method to allow for dilution of the final test cultures to achieve carrier counts within 6.0-7.0 logs is also being proposed. Establishing a range of 6.0-7.0 logs will help improve the reliability of the method and should allow for more consistent results within and among laboratories.

  3. Emergency Dose Estimation Using Optically Stimulated Luminescence from Human Tooth Enamel.

    PubMed

    Sholom, S; Dewitt, R; Simon, S L; Bouville, A; McKeever, S W S

    2011-09-01

    Human teeth were studied for potential use as emergency Optically Stimulated Luminescence (OSL) dosimeters. By using multiple-teeth samples in combination with a custom-built sensitive OSL reader, (60)Co-equivalent doses below 0.64 Gy were measured immediately after exposure with the lowest value being 27 mGy for the most sensitive sample. The variability of OSL sensitivity, from individual to individual using multiple-teeth samples, was determined to be 53%. X-ray and beta exposure were found to produce OSL curves with the same shape that differed from those due to ultraviolet (UV) exposure; as a result, correlation was observed between OSL signals after X-ray and beta exposure and was absent if compared to OSL signals after UV exposure. Fading of the OSL signal was "typical" for most teeth with just a few of incisors showing atypical behavior. Typical fading dependences were described by a bi-exponential decay function with "fast" (decay time around of 12 min) and "slow" (decay time about 14 h) components. OSL detection limits, based on the techniques developed to-date, were found to be satisfactory from the point-of-view of medical triage requirements if conducted within 24 hours of the exposure.

  4. SEMICONDUCTOR PHYSICS Dose-rate dependence of optically stimulated luminescence signal

    NASA Astrophysics Data System (ADS)

    Pingqiang, Wei; Zhaoyang, Chen; Yanwei, Fan; Yurun, Sun; Yun, Zhao

    2010-10-01

    Optically stimulated luminescence (OSL) is the luminescence emitted from a semiconductor during its exposure to light. The OSL intensity is a function of the total dose absorbed by the sample. The dose-rate dependence of the OSL signal of the semiconductor CaS doped Ce and Sm was studied by numerical simulation and experiments. Based on a one-trap/one-center model, the whole OSL process was represented by a series of differential equations. The dose-rate properties of the materials were acquired theoretically by solving the equations. Good coherence was achieved between numerical simulation and experiments, both of which showed that the OSL signal was independent of dose rate. This result validates that when using OSL as a dosimetry technique, the dose-rate effect can be neglected.

  5. A reusable OSL-film for 2D radiotherapy dosimetry

    NASA Astrophysics Data System (ADS)

    Wouter, Crijns; Dirk, Vandenbroucke; Paul, Leblans; Tom, Depuydt

    2017-11-01

    Optical stimulated luminescence (OSL) combines reusability, sub-mm resolution, and a linear dose response in a single radiation detection technology. Such a combination is currently lacking in radiotherapy dosimetry. But OSL-films have a strong energy dependent response to keV photons due to a relative high effective atomic number (Z eff). The current work studied the applicability of a 2D OSL-film with a reduced Z eff as (IMRT/VMAT) dosimeter. Based on their commercial OSL-film experience, Agfa Healthcare N.V. produced a new experimental OSL-film for RT dosimetry. This film had a lower effective atomic number compared to the films used in radiology. Typical 2D dosimeter requirements such as uniformity, dose response, signal stability with time, and angular dependence were evaluated. Additionally, the impact of a possible residual energy dependence was assessed for the infield as well as the out-of-field region of both static beams and standard intensity modulated patterns (chair and pyramid). The OSL-film’s reusable nature allowed for a film specific absolute and linear calibration including a flood-field uniformity correction. The OSL-film was scanned with a CR-15X engine based reader using a strict timing (i.e. 4 min after ‘beam on’ or as soon as possible) to account for spontaneous recombination. The OSL-film had good basic response properties: non-uniformities  ⩽2.6%, a linear dose response (0-32 Gy), a linear signal decay (0.5% min-1) over the 20 min measured, and limited angular dependence  ⩽2.6%. Due to variations of the energy spectrum, larger dose differences were noted outside the central region of the homogenous phantom and outside both static and IMRT fields. However, the OSL-film’s measured dose differences of the IMRT patterns were lower than those of Gafchromic EBT measurements ([-1.6%, 2.1%] versus [-2.9%, 3.6%]). The current OSL-film could be used as a reusable high resolution dosimeter with read-out immediately after irradiation. Inside the (IMRT) treatment fields residual energy dependent effects were not observed. Novelty and significance: Implementing a reusable optical stimulated luminescence (OSL) film for radiotherapy dosimetry would enable user-friendly, sub(mm) resolution 2D dosimetry with instantaneous read-out. Radiology OSL-films have a strong energy dependent response which hampers accurate dosimetry. The current work reports measurements with a first 2D OSL-film tailored to the radiotherapy needs: including an improved water equivalent composition. The dosimeter adds the ability for sub-mm resolution repeated measurements to the portfolio of radiotherapy dosimetry.

  6. A reusable OSL-film for 2D radiotherapy dosimetry.

    PubMed

    Wouter, Crijns; Dirk, Vandenbroucke; Paul, Leblans; Tom, Depuydt

    2017-10-19

    Optical stimulated luminescence (OSL) combines reusability, sub-mm resolution, and a linear dose response in a single radiation detection technology. Such a combination is currently lacking in radiotherapy dosimetry. But OSL-films have a strong energy dependent response to keV photons due to a relative high effective atomic number (Z eff ). The current work studied the applicability of a 2D OSL-film with a reduced Z eff as (IMRT/VMAT) dosimeter. Based on their commercial OSL-film experience, Agfa Healthcare N.V. produced a new experimental OSL-film for RT dosimetry. This film had a lower effective atomic number compared to the films used in radiology. Typical 2D dosimeter requirements such as uniformity, dose response, signal stability with time, and angular dependence were evaluated. Additionally, the impact of a possible residual energy dependence was assessed for the infield as well as the out-of-field region of both static beams and standard intensity modulated patterns (chair and pyramid). The OSL-film's reusable nature allowed for a film specific absolute and linear calibration including a flood-field uniformity correction. The OSL-film was scanned with a CR-15X engine based reader using a strict timing (i.e. 4 min after 'beam on' or as soon as possible) to account for spontaneous recombination. The OSL-film had good basic response properties: non-uniformities  ⩽2.6%, a linear dose response (0-32 Gy), a linear signal decay (0.5% min -1 ) over the 20 min measured, and limited angular dependence  ⩽2.6%. Due to variations of the energy spectrum, larger dose differences were noted outside the central region of the homogenous phantom and outside both static and IMRT fields. However, the OSL-film's measured dose differences of the IMRT patterns were lower than those of Gafchromic EBT measurements ([-1.6%, 2.1%] versus [-2.9%, 3.6%]). The current OSL-film could be used as a reusable high resolution dosimeter with read-out immediately after irradiation. Inside the (IMRT) treatment fields residual energy dependent effects were not observed. Novelty and significance: Implementing a reusable optical stimulated luminescence (OSL) film for radiotherapy dosimetry would enable user-friendly, sub(mm) resolution 2D dosimetry with instantaneous read-out. Radiology OSL-films have a strong energy dependent response which hampers accurate dosimetry. The current work reports measurements with a first 2D OSL-film tailored to the radiotherapy needs: including an improved water equivalent composition. The dosimeter adds the ability for sub-mm resolution repeated measurements to the portfolio of radiotherapy dosimetry.

  7. Studying CaSO4:Eu as an OSL phosphor

    NASA Astrophysics Data System (ADS)

    Guckan, Veysi; Altunal, Volkan; Nur, Necmettin; Depci, Tolga; Ozdemir, Adnan; Kurt, Kasim; Yu, Yan; Yegingil, Ihami; Yegingil, Zehra

    2017-09-01

    This study was carried out to investigate the properties of the OSL signal from Eu-doped calcium sulfate (CaSO4:Eu) phosphor and study on its thermal behavior as a function of temperature under a series of luminescence experiments. The suitability of its usage as an optically stimulated luminescence (OSL) dosimeter was also checked. CaSO4:Eu was synthesized using the precipitation method and prepared in pellet form. The dopant concentration value was performed as 0.1 mol%. The synthesized CaSO4:Eu was analyzed by X-ray diffraction (XRD) method to confirm the product. To have an idea about the crystallography and microstructure morphology of the material, scanning electron microscope (SEM) analysis were carried out. It was found that the OSL signal is a resultant signal having three components and exhibits thermal quenching above 150 °C. The excitation spectrum of CaSO4:Eu showed different peaks in the region 220-360 nm with the highest one at 269 nm. Thermoluminescence (TL) signals of CaSO4:Eu pellets were obtained and compared with the TL signals obtained after OSL measurements of the same pellets by blue light stimulation. The low temperature peak near 180 °C did not show any significant change in TL after OSL measurement whereas the high temperature peak at 240 °C was bleached with the blue light illumination and might be responsible for the observed OSL signal. The dosimetric properties such as dose response, minimum detectable dose, energy response, reusability, fading properties, thermal stability and effect of reading temperatures on OSL signals were examined. OSL signals of CaSO4:Eu pellets were decreased by approximately 8% at the end of the 24 h and by about 7% at the end of 28 days when compared with the first readout. The thermal stability of the ∼240 °C TL peak and OSL signal using isothermal decay measurements were used to determine the trap parameters. The CaSO4:Eu OSL dosimeter in accordance with the presented study allows a high-sensitivity OSL phosphor whose host material was previously known as conventional synthetic CaSO4 TLD material.

  8. Preparation of waterproof OSL dosimeters from hygroscopic materials with a special reference to NaCl:Cu

    NASA Astrophysics Data System (ADS)

    More, Y. K.; Wankhede, S. P.; Patil, R. R.; Kulkarni, M. S.; Kumar, Munish; Moharil, S. V.

    2016-05-01

    Optically stimulated luminescence (OSL) originally developed for geological/archaeological dating, has been found very useful for diverse applications in the field of radiation dosimetry. There is still a scarcity of OSL materials with demonstrated properties suited to dosimetry applications. Progress on the development of OSL materials with engineered properties has been slow and most research has focused on the OSL characterization of existing materials. One of the reasons for availability of only a handful of OSL dosimetry materials with adequate properties is that they have to satisfy certain stringent conditions necessary for such applications. Especially, hygroscopic materials are considered totally unsuitable. The efforts were made in our laboratory to overcome this problem. It is shown here that "water-proof" dosimeters can be prepared from even hygroscopic materials such as NaCl.

  9. Optically stimulated luminescence in x-ray irradiated xSnO-(25-x)SrO-75B2O3 glass

    NASA Astrophysics Data System (ADS)

    Nanto, H.; Nakagawa, R.; Takei, Y.; Hirasawa, K.; Miyamoto, Y.; Masai, H.; Kurobori, T.; Yanagida, T.; Fujimoto, Y.

    2015-06-01

    An intense optically stimulated luminescence (OSL) was observed, for the first time, in x-ray irradiated xSnO-(25-x)SrO-75B2O3 glass. It was found that the peak wavelength of OSL emission spectrum and its stimulation spectrum is about 400 nm and 600 nm, respectively. The OSL intensity is depended on the SnO contents (x=0.05-1.5) and the most intense OSL was observed in 1.0 mol% SnO doped glass. It was found that the OSL intensity is increased with increasing x-ray absorbed dose. Fairly good fading characteristics were observed in the x-ray irradiated glass, showing that this glass is useful as a candidate for OSL sensor materials for ionizing radiation monitoring.

  10. Entrance surface dose measurements using a small OSL dosimeter with a computed tomography scanner having 320 rows of detectors.

    PubMed

    Takegami, Kazuki; Hayashi, Hiroaki; Yamada, Kenji; Mihara, Yoshiki; Kimoto, Natsumi; Kanazawa, Yuki; Higashino, Kousaku; Yamashita, Kazuta; Hayashi, Fumio; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo

    2017-03-01

    Entrance surface dose (ESD) measurements are important in X-ray computed tomography (CT) for examination, but in clinical settings it is difficult to measure ESDs because of a lack of suitable dosimeters. We focus on the capability of a small optically stimulated luminescence (OSL) dosimeter. The aim of this study is to propose a practical method for using an OSL dosimeter to measure the ESD when performing a CT examination. The small OSL dosimeter has an outer width of 10 mm; it is assumed that a partial dose may be measured because the slice thickness and helical pitch can be set to various values. To verify our method, we used a CT scanner having 320 rows of detectors and checked the consistencies of the ESDs measured using OSL dosimeters by comparing them with those measured using Gafchromic™ films. The films were calibrated using an ionization chamber on the basis of half-value layer estimation. On the other hand, the OSL dosimeter was appropriately calibrated using a practical calibration curve previously proposed by our group. The ESDs measured using the OSL dosimeters were in good agreement with the reference ESDs from the Gafchromic™ films. Using these data, we also estimated the uncertainty of ESDs measured with small OSL dosimeters. We concluded that a small OSL dosimeter can be considered suitable for measuring the ESD with an uncertainty of 30 % during CT examinations in which pitch factors below 1.000 are applied.

  11. LiMgPO 4:Tb,B - A new sensitive OSL phosphor for dosimetry

    NASA Astrophysics Data System (ADS)

    Dhabekar, Bhushan; Menon, S. N.; Alagu Raja, E.; Bakshi, A. K.; Singh, A. K.; Chougaonkar, M. P.; Mayya, Y. S.

    2011-08-01

    Optically Stimulated Luminescence (OSL) technique has emerged as a serious competitor to Thermally Stimulated Luminescence (TSL) technique in various dosimetric applications, especially after the development of crystalline alumina (Al 2O 3:C) doped with carbon. Since then, several attempts are being made to develop other possible materials for OSL based dosimetric applications. Efforts conducted in our laboratory in this direction have led to the development of a new phosphor, Lithium Magnesium Phosphate doped with terbium and boron (LiMgPO 4:Tb,B). This phosphor is prepared by solid-state diffusion method involving conventional air furnaces with operating temperature 1000 °C and easily amenable to large scale production without compromising primary dosimetric advantages. In this work we present some of the dosimetric OSL characteristics of this phosphor. The phosphor exhibits a main TSL peak at 250 °C. The phosphor also emits OSL, when the irradiated phosphor is stimulated with 470 nm light with the OSL sensitivity 1.3 times that of commercially available Al 2O 3:C. Photoluminescence (PL) emission spectrum consists of sharp lines characteristics of Tb 3+ emission. The OSL discs made out of this phosphor are reusable up to at least 50 cycles, the phosphor exhibits dose linearity up to 1 kGy. Minimum detectable dose is found to be 20 μGy and fading of the OSL signal is found to be about 16% in four days, after which the OSL signal stabilizes.

  12. Optically Stimulated Luminescence (OSL) of dental enamel for retrospective assessment of radiation exposure

    PubMed Central

    Yukihara, E.G.; Mittani, J.; McKeever, S.W.S.; Simon, S.L.

    2009-01-01

    This paper briefly reviews the optically stimulated luminescence (OSL) properties of dental enamel and discusses the potential and challenges of OSL for filling the technology gap in biodosimetry required for medical triage following a radiological/nuclear accident or terrorist event. The OSL technique uses light to stimulate a radiation-induced luminescence signal from materials previously exposed to ionizing radiation. This luminescence originates from radiation-induced defects in insulating crystals and is proportional to the absorbed dose of ionizing radiation. In our research conducted to date, we focused on fundamental investigations of the OSL properties of dental enamel using extracted teeth and tabletop OSL readers. The objective was to obtain information to support the development of the necessary instrumentation for retrospective dosimetry using dental enamel in laboratory, or for in situ and non-invasive accident dosimetry using dental enamel in emergency triage. An OSL signal from human dental enamel was detected using blue, green, or IR stimulation. Blue/green stimulation associated with UV emission detection seems to be the most appropriate combination in the sense that there is no signal from un-irradiated samples and the shape of the OSL decay is clear. Improvements in the minimum detection level were achieved by incorporating an ellipsoidal mirror in the OSL system to maximize light collection. Other possibilities to improve the sensitivity and research steps necessary to establish the feasibility of the technique for retrospective assessment of radiation exposure are also discussed. PMID:19623269

  13. Emergency Dose Estimation Using Optically Stimulated Luminescence from Human Tooth Enamel

    PubMed Central

    Sholom, S.; DeWitt, R.; Simon, S.L.; Bouville, A.; McKeever, S.W.S.

    2011-01-01

    Human teeth were studied for potential use as emergency Optically Stimulated Luminescence (OSL) dosimeters. By using multiple-teeth samples in combination with a custom-built sensitive OSL reader, 60Co-equivalent doses below 0.64 Gy were measured immediately after exposure with the lowest value being 27 mGy for the most sensitive sample. The variability of OSL sensitivity, from individual to individual using multiple-teeth samples, was determined to be 53%. X-ray and beta exposure were found to produce OSL curves with the same shape that differed from those due to ultraviolet (UV) exposure; as a result, correlation was observed between OSL signals after X-ray and beta exposure and was absent if compared to OSL signals after UV exposure. Fading of the OSL signal was “typical” for most teeth with just a few of incisors showing atypical behavior. Typical fading dependences were described by a bi-exponential decay function with “fast” (decay time around of 12 min) and “slow” (decay time about 14 h) components. OSL detection limits, based on the techniques developed to-date, were found to be satisfactory from the point-of-view of medical triage requirements if conducted within 24 hours of the exposure. PMID:21949479

  14. Tl And Osl Response Of Turquoise For Dosimetric Application

    NASA Astrophysics Data System (ADS)

    Subedi, B.; Afouxenidis, D.; Polymeris, G. S.; Tsirlignanis, N.; Paraskevopoulos, K. M.; Kitis, G.

    Turquoise is one of the amongst first gem stones used in jewelry and possessing cultural value since 2000 BC (at least). This work attempts characterize this stone scientifically using both thermally (TL) and optically stimulated luminescence (OSL) techniques. The experimental investigation included 1) the study of the natural TL and OSL signals, 2) the reproducibility of TL sensitivity over repeated irradiation and TL readout cycles, 3) dependence of sensitivity on annealing temperatures and 4) the TL and OSL dose response curves. The potential use of the TL and OSL techniques in determination of provenance, accidental dosimetry and probably to authenticity and dating purposes are then discussed.

  15. Characterization of α-spodumene to OSL dosimetry

    NASA Astrophysics Data System (ADS)

    d'Amorim, R. A. P. O.; de Vasconcelos, D. A. A.; de Barros, V. S. M.; Khoury, H. J.; Souza, S. O.

    2014-02-01

    The aim of this paper is to evaluate the optically stimulated luminescence (OSL) response of spodumene (LiAlSi2O6) silicate and its potential use for gamma radiation dosimetry. A natural Brazilian crystal of α-spodumene was used in this study. After the crystal grinding, pellets with the diameter of 6.0 mm were prepared using a mixture of α-spodumene and polytetrafluoroethylene (Teflon®) (1:2). To study the OSL response, the samples were irradiated with gamma radiation beam of Co-60 and the response was measured using an OSL Reader in two modes of operation: Continuous-wave and pulsed stimulation. The results of the integrated OSL curve of the pellets irradiated with the dose of 30 Gy showed that their response is reproducible within ±2%. The variation of the OSL response upon the dose exhibits a linear response in the range from 30 Gy to 10 kGy, with a correlation coefficient of 0.99. It is possible to conclude that the α-LiAlSi2O6/Teflon® has a great potential for OSL dosimetry of high gamma doses.

  16. Hormones and growth factors in the pathogenesis of spinal ligament ossification

    PubMed Central

    Li, Hai; Jiang, Lei-Sheng

    2007-01-01

    Ossification of the spinal ligaments (OSL) is a pathologic condition that causes ectopic bone formation and subsequently results in various degrees of neurological deficit, but the etiology of OSL remains almost unknown. Some systemic hormones, such as 1,25-dihydroxyvitamin D, parathyroid hormone (PTH), insulin and leptin, and local growth factors, such as transforming growth factor-β (TGF-β), and bone morphogenetic protein (BMP), have been studied and are thought to be involved in the initiation and development of OSL. This review article summarizes these studies, delineates the possible mechanisms, and puts forward doubts and new questions. The related findings from studies of genes and target cells in the ligament of OSL are also discussed. Although these findings may be helpful in understanding the pathogenesis of OSL, much more research needs to be conducted in order to investigate the nature of OSL. PMID:17426989

  17. Hormones and growth factors in the pathogenesis of spinal ligament ossification.

    PubMed

    Li, Hai; Jiang, Lei-Sheng; Dai, Li-Yang

    2007-08-01

    Ossification of the spinal ligaments (OSL) is a pathologic condition that causes ectopic bone formation and subsequently results in various degrees of neurological deficit, but the etiology of OSL remains almost unknown. Some systemic hormones, such as 1,25-dihydroxyvitamin D, parathyroid hormone (PTH), insulin and leptin, and local growth factors, such as transforming growth factor-beta (TGF-beta), and bone morphogenetic protein (BMP), have been studied and are thought to be involved in the initiation and development of OSL. This review article summarizes these studies, delineates the possible mechanisms, and puts forward doubts and new questions. The related findings from studies of genes and target cells in the ligament of OSL are also discussed. Although these findings may be helpful in understanding the pathogenesis of OSL, much more research needs to be conducted in order to investigate the nature of OSL.

  18. Preparation of waterproof OSL dosimeters from hygroscopic materials with a special reference to NaCl:Cu

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    More, Y. K., E-mail: moreyogesh153@gmail.com; Moharil, S. V.; Wankhede, S. P.

    Optically stimulated luminescence (OSL) originally developed for geological/archaeological dating, has been found very useful for diverse applications in the field of radiation dosimetry. There is still a scarcity of OSL materials with demonstrated properties suited to dosimetry applications. Progress on the development of OSL materials with engineered properties has been slow and most research has focused on the OSL characterization of existing materials. One of the reasons for availability of only a handful of OSL dosimetry materials with adequate properties is that they have to satisfy certain stringent conditions necessary for such applications. Especially, hygroscopic materials are considered totally unsuitable.more » The efforts were made in our laboratory to overcome this problem. It is shown here that “water-proof” dosimeters can be prepared from even hygroscopic materials such as NaCl.« less

  19. OSL properties of KMgF3:Tm3+ for dosimetric applications as OSL dosimeter.

    PubMed

    Camargo, Luis; Cruz, Lituania Pérez; Cruz-Zaragoza, Epifanio; Ovalle, Segundo Martínez; Marcazzó, Julián

    2018-04-06

    The optically stimulated luminescence (OSL) properties of undoped and Tm 3+ -doped KMgF 3 fluoroperovskite have been investigated for the first time. KMgF 3 compounds were synthesized by solid state reaction method and two different procedures were employed to improve the contact among the reagents, namely, the compressed powder was put either in an alumina crucible or in a platinum foil. The maximum OSL emission was found in samples prepared in an alumina crucible and doped with 0.5% mol of thulium. The radioluminescence (RL) spectrum shows two emission peaks at 455 and 360 nm, which can be ascribed to the 1 D 2 - 3 F 4 and 1 D 2 - 3 H 6 transitions of Tm 3+ cations. The OSL dosimetric properties of the most promising composition, namely, KMgF 3 :Tm 3+ (0.5% mol), have also been determined and analyzed. This compound exhibits good linearity in the dose range from 0.1 up to 100 Gy and satisfactory repeatability with a percentage standard deviation of 2.4%. Therefore, an OSL fading of approximately 75% in the first 36 h of storage is observed and then, the response remains almost constant. These characteristics, together with a minimum detectable dose of 0.04 Gy and the rapid erasing of the OSL signal after 100 s of stimulation, which makes feasible to bleach completely the residual OSL in order to restore the sample between dose measurements, suggest the potential of this perovskite as OSL dosimeter. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Optically Stimulated Luminescence Analysis Method for High Dose Rate Using an Optical Fiber Type Dosimeter

    NASA Astrophysics Data System (ADS)

    Ueno, Katsunori; Tominaga, Kazuo; Tadokoro, Takahiro; Ishizawa, Koji; Takahashi, Yoshinori; Kuwabara, Hitoshi

    2016-08-01

    The investigation of air dose rates at locations in the Fukushima Dai-ichi Nuclear Power Station is necessary for safe removal of the molten nuclear fuel. The target performance for the investigation is to analyze a dose rate in the range of 10-3 Gy/h to 102 Gy/h with a measurement precision of ±4.0% full scale (F.S.) at a measurement interval of 60 s. In order to achieve this target, the authors proposed an optically stimulated luminescence (OSL) analysis method using prompt OSL for a wide dynamic range of dose rates; the OSL is generated using BaFBr:Eu with a fast decay time constant. The luminescence intensity by prompt OSL was formulated by the electron concentration of the trapping state during gamma ray and stimulation light irradiations. The prototype OSL monitor using BaFBr:Eu was manufactured for investigation of prompt OSL and evaluation of the measurement precision. The time dependence of the luminescence intensity by prompt OSL was analyzed by irradiating the OSL sensor in a 60Co irradiation facility. The measured dose rates were obtained in a prompt mode and an accumulating mode with a precision of ±3.3% F.S. for the dose rate range of 9.5 ×10-4 Gy/h to 1.2 ×102 Gy/h.

  1. Time-resolved optically stimulated luminescence of Al2O3:C for ion beam therapy dosimetry

    NASA Astrophysics Data System (ADS)

    Yukihara, Eduardo G.; Doull, Brandon A.; Ahmed, Md; Brons, Stephan; Tessonnier, Thomas; Jäkel, Oliver; Greilich, Steffen

    2015-09-01

    The objective of this study was to characterize the time-resolved (TR) optically stimulated luminescence (OSL) from Al2O3:C detectors and investigate methodologies to improve the accuracy of these detectors in ion beam therapy dosimetry, addressing the reduction in relative response to high linear energy transfer (LET) particles common to solid-state detectors. Al2O3:C OSL detectors (OSLDs) were exposed to proton, 4He, 12C and 16O beams in 22 particle/energy combinations and read using a custom-built TR-OSL reader. The OSL response {{r}\\text{OSL}} , relative to 60Co gamma dose to water, and the ratio between the UV and blue OSL emission bands of Al2O3:C (UV/blue ratio) were determined as a function of the LET. Monte-Carlo simulations with the multi-purpose interaction and transport code FLUKA were used to estimate the absorbed doses and particle energy spectra in the different irradiation conditions. The OSL responses {{r}\\text{OSL}} varied from 0.980 (0.73 keV μm-1) to 0.288 (120.8 keV μm-1). The OSL UV/blue ratio varied by a factor of two in the investigated LET range, but the variation for 12C beams was only 11%. OSLDs were also irradiated at different depths of carbon ion spread-out Bragg peaks (SOBPs), where it was shown that doses could be obtained with an accuracy of  ±2.0% at the entrance channel and within the SOBP using correction factors calculated based on the OSL responses obtained in this study. The UV/blue ratio did not allow accurate estimation of the dose-averaged LET for 12C SOBPs, although the values obtained can be explained with the data obtained in this study and the additional information provided by the Monte-Carlo simulations. The results demonstrate that accurate OSLD dosimetry can be performed in ion beam therapy using appropriate corrections for the OSL response.

  2. SU-F-T-327: Total Body Irradiation In-Vivo Dose Measurements Using Optically Stimulated Luminescence (OSL) NanoDots and Farmer Type Ion Chamber

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaur, H; Kumar, S; Sarkar, B

    Purpose: This study was performed to analyze the agreement between optically stimulated luminescence (OSL) nanoDots measured doses and 0.6 cc Farmer type ionization chamber measured doses during total body irradiation (TBI). Methods: In-vivo dose measurements using OSL nanoDots and Farmer chamber were done in a total of twelve patients who received TBI at our center by bilateral parallel-opposed beams technique. In this technique, the patient is kept inside the TBI box which is filled with rice bags and irradiated using two bilateral parallel opposed beams of 40×40 cm{sup 2} size with 45° collimator rotation at an SSD of 333.5 cmmore » in an Elekta Synergy linear accelerator. All patients received a dose of 2 Gy in single fraction as conditioning regimen. The beams were equally weighted at the midplane of the box. The nanoDots were placed over forehead, right and left neck, right and left lung, umbilicus, right and left abdomen, medial part of thigh, knee and toe. A 0.6 cc Farmer chamber was placed in between the thighs of the patient. Measured doses are reported along with the statistical comparisons using paired sample t-test. Results: For the above sites the mean doses were 212.2±21.1, 218.2±7.6, 218.7±9.3, 215.6±9.5, 217.5±11.5, 214.5±7.7, 218.3±6.8, 221.5±15, 229.1±11.0, 220.5±7.7 and 223.3±5.1 cGy respectively. For all OSL measurements the mean dose was 218.6±11.8 cGy. Farmer chamber measurements yielded a mean dose of 208.8±15.6 cGy. Statistical analysis revealed that there was no significant difference between OSL measured doses in forehead, right and left neck, right and left lung, umbilicus, right and left abdomen and toe and Farmer chamber measured doses (0.72≤p≤0.06). However the mean OSL doses at thigh and knee were statistically different (p<0.05) from the Farmer chamber measurements. Conclusion: OSL measurements were found to be in agreement with Farmer type ionization chamber measurements in in-vivo dosimetry of TBI.« less

  3. Verifying the new luminescence surface-exposure dating technique--rock falls in Canyonlands National Park, Utah

    NASA Astrophysics Data System (ADS)

    Pederson, J. L.; Sohbati, R.; Murray, A. S.; Jain, M.

    2015-12-01

    Recent studies have helped develop the optically stimulated luminescence (OSL) dating of rock surfaces, as applied to the age of the famous Great Gallery rock art panel in Canyonlands National Park. Chapot et al. (2012) dated a key rock fall to ~900 yrs ago by applying OSL to the outer 1-mm buried surface of a sandstone talus boulder, an age confirmed by independent radiocarbon dating. Later, in a novel approach and with the use of a local known-age calibration sample, Sohbati et al. (2012) modelled the millimeter-scale OSL-depth profile to determine a pre-burial exposure duration of ~700 years for the same rock fall. This combination of rock-fall dating and exposure dating--an approach with broad potential to date Holocene mass movements--constrains the creation of the Great Gallery rock art to a time window of 900 to ~1600 years ago (Pederson et al., 2014), a result met with some controversy. Here we report on a new phase of research to verify these results and further refine OSL-profile exposure dating for mass movements. New analyses from within and near the Great Gallery alcove include: i) exposure dating of the same alcove surface upon which the rock art is painted with a predicted exposure age of ~1600 years; ii) exposure dating of the top (light-exposed) side of the same rock-fall boulder whose buried side was previously dated to test for reproduction of the known age; and iii) an improved calibration sample from a nearby trail/road-cut for verification. The residual OSL signal is measured with depth in millimeter-thick increments of all samples. We first determine the site-specific luminescence reduction rate at the rock surface by fitting the OSL surface-exposure dating model to the calibration profile from the trail/road-cut. This parameterized model then provides exposure ages for the bleaching profiles observed in the other samples. Results have implications for the application of OSL rock-surface and exposure-profile dating in other settings where quartz-rich rock is available. We discuss how the light-exposed top and buried underside of clasts can be used in tandem for calibration. The technique has particular relevance to younger timescales over which cosmogenic nuclides are of limited application.

  4. Evaluation of a real-time BeO ceramic fiber-coupled luminescence dosimetry system for dose verification of high dose rate brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santos, Alexandre M. Caraça, E-mail: alexandre.santos@adelaide.edu.au; Mohammadi, Mohammad; Shahraam, Afshar V.

    Purpose: The authors evaluate the capability of a beryllium oxide (BeO) ceramic fiber-coupled luminescence dosimeter, named radioluminescence/optically stimulated luminescence (RL/OSL) BeO FOD, for dosimetric verification of high dose rate (HDR) treatments. The RL/OSL BeO FOD is capable of RL and OSL measurements. Methods: The RL/OSL BeO FOD is able to be inserted in 6F proguide needles, used in interstitial HDR treatments. Using a custom built Perspex phantom, 6F proguide needles could be submerged in a water tank at 1 cm separations from each other. A second background fiber was required to correct for the stem effect. The stem effect, dosemore » linearity, reproducibility, depth-dose curves, and angular and temperature dependency of the RL/OSL BeO FOD were characterised using an Ir-192 source. The RL/OSL BeO FOD was also applied to the commissioning of a 10 mm horizontal Leipzig applicator. Results: Both the RL and OSL were found to be reproducible and their percentage depth-dose curves to be in good agreement with those predicted via TG-43. A combined uncertainty of 7.9% and 10.1% (k = 1) was estimated for the RL and OSL, respectively. For the 10 mm horizontal Leipzig applicator, measured percentage depth doses were within 5% agreement of the published reference calculations. The output at the 3 mm prescription depth for a 1 Gy delivery was verified to be 0.99 ± 0.08 Gy and 1.01 ± 0.10 Gy by the RL and OSL, respectively. Conclusions: The use of the second background fiber under the current setup means that the two fibers cannot fit into a single 6F needle. Hence, use of the RL is currently not adequate for the purpose of in vivo brachytherapy dosimetry. While not real-time, the OSL is shown to be adequate for in vivo brachytherapy dosimetry.« less

  5. Evaluation of a real-time BeO ceramic fiber-coupled luminescence dosimetry system for dose verification of high dose rate brachytherapy.

    PubMed

    Santos, Alexandre M Caraça; Mohammadi, Mohammad; Afshar V, Shahraam

    2015-11-01

    The authors evaluate the capability of a beryllium oxide (BeO) ceramic fiber-coupled luminescence dosimeter, named radioluminescence/optically stimulated luminescence (RL/OSL) BeO FOD, for dosimetric verification of high dose rate (HDR) treatments. The RL/OSL BeO FOD is capable of RL and OSL measurements. The RL/OSL BeO FOD is able to be inserted in 6F proguide needles, used in interstitial HDR treatments. Using a custom built Perspex phantom, 6F proguide needles could be submerged in a water tank at 1 cm separations from each other. A second background fiber was required to correct for the stem effect. The stem effect, dose linearity, reproducibility, depth-dose curves, and angular and temperature dependency of the RL/OSL BeO FOD were characterised using an Ir-192 source. The RL/OSL BeO FOD was also applied to the commissioning of a 10 mm horizontal Leipzig applicator. Both the RL and OSL were found to be reproducible and their percentage depth-dose curves to be in good agreement with those predicted via TG-43. A combined uncertainty of 7.9% and 10.1% (k=1) was estimated for the RL and OSL, respectively. For the 10 mm horizontal Leipzig applicator, measured percentage depth doses were within 5% agreement of the published reference calculations. The output at the 3 mm prescription depth for a 1 Gy delivery was verified to be 0.99±0.08 Gy and 1.01±0.10 Gy by the RL and OSL, respectively. The use of the second background fiber under the current setup means that the two fibers cannot fit into a single 6F needle. Hence, use of the RL is currently not adequate for the purpose of in vivo brachytherapy dosimetry. While not real-time, the OSL is shown to be adequate for in vivo brachytherapy dosimetry.

  6. Optically stimulated luminescence in doped NaCl

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaikwad, S. U., E-mail: gaikwadsonali09@yahoo.com; Patil, R. R.; Kulkarni, M. S.

    NaCl:Ca,Cu,P NaCl:Mg,Cu,P OSL phosphors are synthesized. Intense OSL is observed in these samples which is 14 times more than Al{sub 2}O{sub 3}:C. Same samples coated with PVA (poly vinyl actetae) polymer also show similar OSL properties and these coated samples are found to be less susceptible to the moisture due to protected layer of hydrophobic polymer. These coated samples may be useful as OSL dosimetersdue to high sensitivity and less or no susceptibility to moisture.

  7. Influence of shallow traps on time-resolved optically stimulated luminescence measurements of Al2O3:C,Mg

    NASA Astrophysics Data System (ADS)

    Denis, G.; Akselrod, M. S.; Yukihara, E. G.

    2011-05-01

    The objective of this paper is to investigate the influence of shallow traps on the signals from Al2O3:C,Mg obtained using time-resolved optically stimulated luminescence (TR-OSL) measurements through experiments and numerical simulations. TR-OSL measurements of Al2O3:C,Mg were carried out and the resulting optically stimulated luminescence (OSL) curves were investigated as a function of the temperature. The numerical simulations were carried out using the rate-equations for a simplified model of Al2O3:C,Mg containing two types of luminescence centers with different luminescence lifetimes and three types of electron traps (a shallow trap, a main dosimetric trap, and a thermally disconnected deep trap). Both experimental results and simulations show that the OSL signals during and between the stimulation pulses are affected by the presence of shallow traps. However, with an appropriate choice of timing parameters, the influence of shallow traps can be reduced by calculating the difference between the signals during and between stimulation pulses. Therefore, TR-OSL can be useful in dosimetry using materials having a large concentration of shallow traps and OSL components with short luminescence lifetimes, for example Al2O3:C,Mg and BeO. Our results also show that the presence of shallow traps has to be taken into account when using the TR-OSL for discrimination between luminescence centers with different luminescence lifetimes, or separation between the OSL from different materials based on their characteristic luminescence lifetimes. The experimental results also show evidence of thermal assistance in the OSL process of Al2O3:C,Mg.

  8. OSL studies of alkali fluoroperovskite single crystals for radiation dosimetry

    NASA Astrophysics Data System (ADS)

    Daniel, D. Joseph; Raja, A.; Madhusoodanan, U.; Annalakshmi, O.; Ramasamy, P.

    2016-08-01

    This paper presents a preliminary investigation of the optically stimulated luminescence (OSL) of alkali fluoroperovskite single crystals for radiation dosimetry. The perovskite-like KMgF3, NaMgF3 and LiBaF3 polycrystalline compounds doped with rare earths (Eu2+ and Ce3+) were synthesized by standard solid state reaction technique. Phase purity of the synthesized compounds was analyzed by powder X-ray diffraction technique. Single crystals of these compounds have been grown from melt by using vertical Bridgman-Stockbarger method. The Linearly Modulated OSL and Continuous Wave OSL measurements were performed in these alkali fluorides using blue light stimulation. Thermal bleaching experiments have shown that OSL signals originate from traps which are unstable near 200 °C, thus proving the suitability of the signals for dosimetric purposes. Optical bleaching measurements were also performed for these fluoride samples. OSL dose response was studied as a function of dose which was found to increase with beta dose.

  9. Determination of multislice computed tomography dose index (CTDI) using optically stimulated luminescence technology.

    PubMed

    Ruan, Chun; Yukihara, Eduardo G; Clouse, William J; Gasparian, Patricia B R; Ahmad, Salahuddin

    2010-07-01

    The extensive use of multislice computed tomography (MSCT) and the associated increase in patient dose calls for an accurate dose evaluation technique. Optically stimulated luminescence (OSL) dosimetry provides a potential solution to the arising concerns over patient dose. This study was intended to evaluate the feasibility and accuracy of OSL dosimeter systems in the diagnostic CT x-ray beam energy range. MSCT dose profiles were measured by irradiating OSL strips placed inside the extended PMMA head and body phantoms at different scan conditions by varying kVp settings (100, 120, and 140 kVp) and collimated beam widths (5, 10, 20, and 40 mm). All scans in this study were performed using a GE Lightspeed VCT scanner in axial mode. The exposed strips were then read out using a custom-made OSL strip reader and corrected with field-specific conversion factors. Based on the corrected OSL dose profile, the CTDI(450-OSL) and CTDI(l00-OSL) were evaluated. CTDI(100-IC) was also obtained using a 100 mm long pencil ionization chamber for accuracy verification. CTDI(100-efficiency) can be further evaluated by calculating the ratio of CTDI(100-OSL) and CTDI(450-OSL), which was compared to results from previous studies as well. The OSL detectors were found to have good sensitivity and dose response over a wide range of diagnostic CT x-ray beam energy viz. the primary beam and the scatter tail section of the dose profile. The differences between CTDI100 values obtained using the OSL strips and those obtained with 100 mm long pencil ionization chamber were < +/- 5% for all scan conditions, indicating good accuracy of the OSL system. It was also found that the CTDI(100-efficiency) did not significantly change as the beam width increased and tube voltage changed. The average CTDI(100-efficiency) at the center of the head and body phantoms were 72.6% and 56.2%, respectively. The corresponding values for the periphery of the head and body phantoms were 85.0% and 81.7%. These results agreed very well with previous results from the literature using other detection techniques or Monte Carlo simulations. The LED-based OSL system can be an accurate alternative device for CT dose evaluations. CTDI100 measurement with the use of a 100 mm pencil ionization chamber substantially underestimates the CTDIinfinity value even with 5 mm collimated beam width. The established complete set of CTDI(100-efficiency) correction factors for various scan parameters allows for accurately estimating CTDIinfinity with the current use of pencil chamber and dose phantoms. Combined with the simple calibration, it gives this work great potential to be used not only in routine clinical quality assurance checks but also as a promising tool for patient organ dose assessment.

  10. Finnish spectrolite as high-dose gamma detector

    NASA Astrophysics Data System (ADS)

    Antonio, Patrícia L.; Caldas, Linda V. E.

    2015-11-01

    A natural material called spectrolite, from Finland, was studied in this work. The purpose was to test it in gamma radiation beams to verify its performance as a high-dose detector. From this material, pellets were manufactured with two different concentrations of Teflon and spectrolite, and their responses were verified using two luminescent techniques: thermoluminescence (TL) and optically stimulated luminescence (OSL). The TL and OSL signals were evaluated by means of characterization tests of the material response, after exposure to a nominal absorbed dose interval of 5 Gy to 10 kGy. The results obtained, for both concentrations, showed a good performance of this material in beams of high-dose gamma radiation. Both techniques were utilized in order to investigate the properties of the spectrolite+Teflon samples for different applications.

  11. Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors.

    PubMed

    Karsch, L; Beyreuther, E; Burris-Mog, T; Kraft, S; Richter, C; Zeil, K; Pawelke, J

    2012-05-01

    The use of laser accelerators in radiation therapy can perhaps increase the low number of proton and ion therapy facilities in some years due to the low investment costs and small size. The laser-based acceleration technology leads to a very high peak dose rate of about 10(11) Gy∕s. A first dosimetric task is the evaluation of dose rate dependence of clinical dosimeters and other detectors. The measurements were done at ELBE, a superconductive linear electron accelerator which generates electron pulses with 5 ps length at 20 MeV. The different dose rates are reached by adjusting the number of electrons in one beam pulse. Three clinical dosimeters (TLD, OSL, and EBT radiochromic films) were irradiated with four different dose rates and nearly the same dose. A faraday cup, an integrating current transformer, and an ionization chamber were used to control the particle flux on the dosimeters. Furthermore two diamond detectors were tested. The dosimeters are dose rate independent up to 4●10(9) Gy∕s within 2% (OSL and TLD) and up to 15●10(9) Gy∕s within 5% (EBT films). The diamond detectors show strong dose rate dependence. TLD, OSL dosimeters, and EBT films are suitable for pulsed beams with a very high pulse dose rate like laser accelerated particle beams.

  12. Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karsch, L.; Beyreuther, E.; Burris-Mog, T.

    Purpose: The use of laser accelerators in radiation therapy can perhaps increase the low number of proton and ion therapy facilities in some years due to the low investment costs and small size. The laser-based acceleration technology leads to a very high peak dose rate of about 10{sup 11} Gy/s. A first dosimetric task is the evaluation of dose rate dependence of clinical dosimeters and other detectors. Methods: The measurements were done at ELBE, a superconductive linear electron accelerator which generates electron pulses with 5 ps length at 20 MeV. The different dose rates are reached by adjusting the numbermore » of electrons in one beam pulse. Three clinical dosimeters (TLD, OSL, and EBT radiochromic films) were irradiated with four different dose rates and nearly the same dose. A faraday cup, an integrating current transformer, and an ionization chamber were used to control the particle flux on the dosimeters. Furthermore two diamond detectors were tested. Results: The dosimeters are dose rate independent up to 410{sup 9} Gy/s within 2% (OSL and TLD) and up to 1510{sup 9} Gy/s within 5% (EBT films). The diamond detectors show strong dose rate dependence. Conclusions: TLD, OSL dosimeters, and EBT films are suitable for pulsed beams with a very high pulse dose rate like laser accelerated particle beams.« less

  13. Construction ages of the Upton Stone Chamber: Preliminary findings and suggestions for future luminescence research

    USGS Publications Warehouse

    Mahan, Shannon; Martin, Frederick; Taylor, Cathy

    2015-01-01

    The Upton Chamber in Massachusetts, an earth-covered stone structure 3.4 meters (m) in diameter, with a corbelled stone dome, and a 4.3 m long entrance passageway, is studied with the aim of determining whether optically stimulated luminescence (OSL) dating methods can be used to establish the approximate construction date of the entranceway. Three samples, taken from soil behind the lowest stones in the wall of the entrance passageway, returned OSL ages between 385 and 660 years ago (or from 1625 A.D. to 1350 A.D.; using the year 2011 as the 0 year). One sample, taken below the bottom of the artifact layers in an archeological test pit in front of the chamber entrance, returned OSL ages between 650 and 880 years ago. A modern sample collected from a nearby fluvial channel returned an age between 55 and 175 years. The Upton Chamber OSL sampling results are challenging to interpret because there are mixtures in the samples of both younger and older grains that likely result from human modification, root or soil processes, animal bioturbation (i.e. ants and worms), and/or partial bleaching. The ages were determined using the lowest component of the finite mixture model as applied to a distribution of quartz grains. Further research may enable us to determine whether older components are of anthropomorphic or geological origin.

  14. [Fabrication of annealing equipment for optically stimulated luminescence (OSL) dosimeter].

    PubMed

    Nakagawa, Kohei; Hayashi, Hiroaki; Okino, Hiroki; Takegami, Kazuki; Okazaki, Tohru; Kobayashi, Ikuo

    2014-10-01

    The optically stimulated luminescence (OSL) dosimeter is a useful detector for measuring absorbed doses of X-rays. A small-type OSL dosimeter, "nanoDot", has recently been developed by Landauer, Inc., who also manufacture "microStar" reading equipment. However, additional annealing equipment is needed if the nanoDot OSL dosimeter is used repeatedly. The aim of this study was to fabricate suitable annealing equipment using commonly available products. Our device positions four fluorescent light tubes in a close configuration. The heat from the fluorescent light tubes is dissipated using fans. Experiments using diagnostic X-ray equipment were carried out to evaluate the capability of our annealing equipment. The results indicated that our equipment can fully anneal the nanoDot OSL dosimeter with annealing times of approximately 20 hours.

  15. An optically stimulated luminescence system to measure dose profiles in x-ray computed tomography

    NASA Astrophysics Data System (ADS)

    Yukihara, E. G.; Ruan, C.; Gasparian, P. B. R.; Clouse, W. J.; Kalavagunta, C.; Ahmad, S.

    2009-10-01

    This paper describes an LED-based optically stimulated luminescence (OSL) system for dose profile measurements using OSL detector strips and investigates its performance in x-ray computed tomography (CT) dosimetry. To compensate for the energy response of the Al2O3:C OSL detectors, which have an effective atomic number of 11.28, field-specific energy correction factors were determined using two methods: (a) comparing the OSL profiles with ionization chamber point measurements (0.3 cm3 ionization chamber) and (b) comparing the OSL profiles integrated over a 100 mm length with 100 mm long pencil ionization chamber measurements. These correction factors were obtained for the CT body and head phantoms, central and peripheral positions and three x-ray tube potential differences (100 kVp, 120 kVp and 140 kVp). The OSL dose profiles corrected by the energy dependence agreed with the ionization chamber point measurements over the entire length of the phantom (300 mm). For 120 kVp x-ray tube potential difference, the CTDI100 values calculated using the OSL dose profiles corrected for the energy dependence and those obtained from an independent measurement with a 100 mm long pencil ionization chamber also agreed within ±5%.

  16. Fundamentals of materials, techniques and instrumentation for OSL and FNTD dosimetry

    NASA Astrophysics Data System (ADS)

    Akselrod, M. S.

    2013-02-01

    The optically stimulated luminescence (OSL) technique has already become a successful commercial tool in personal radiation dosimetry, medical dosimetry, diagnostic imaging, geological and archeological dating. This review briefly describes the history and fundamental principles of OSL materials, methods and instrumentation. The advantages of OSL technology and instrumentation in comparison with thermoluminescent technique are analyzed. Progress in material and detector engineering has allowed new and promising developments regarding OSL applications in the medical field. Special attention is dedicated to Al2O3:C as a material of choice for many dosimetric applications including fiberoptic OSL/RL sensors with diameters as small as 300 μm. A new RL/OSL fiberoptic system has a high potential for in vivo and in vitro dosimetry in both radiation therapy and diagnostic mammography. Different aspects of instrumentation, data processing algorithms, post-irradiation and real-time measurements are described. The next technological breakthrough was done with Fluorescent Nuclear Track detectors (FNTD) that has some important advantages in measuring fast neutron and high energy heavy charge particles that became the latest tool in radiation therapy. New Mg-doped aluminum oxide crystals and novel type of imaging instrumentation for FNTD technology were engineered and successfully demonstrated for occupational and accident dosimetry, for medical dosimetry and radiobiological research.

  17. Recent developments of optically stimulated luminescence materials and techniques for radiation dosimetry and clinical applications.

    PubMed

    Pradhan, A S; Lee, J I; Kim, J L

    2008-07-01

    During the last 10 years, optically stimulated luminescence (OSL) has emerged as a formidable competitor not only to thermoluminescence dosimetry (TLD) but also to several other dosimetry systems. Though a large number of materials have been synthesized and studied for OSL, Al(2)O(3):C continues to dominate the dosimetric applications. Re-investigations of OSL in BeOindicate that this material might provide an alternative to Al(2)O(3):C. Study of OSL of electronic components of mobile phones and ID cards appears to have opened up a feasibility of dosimetry and dose reconstruction using the electronic components of gadgets of everyday use in the events of unforeseen situations of radiological accidents, including the event of a dirty bomb by terrorist groups. Among the newly reported materials, a very recent development of NaMgF(3):Eu(2+) appears fascinating because of its high OSL sensitivity and tolerable tissue equivalence. In clinical dosimetry, an OSL as a passive dosimeter could do all that TLD can do, much faster with a better or at least the same efficiency; and in addition, it provides a possibility of repeated readout unlike TLD, in which all the dose information is lost in a single readout. Of late, OSL has also emerged as a practical real-time dosimeter for in vivo measurements in radiation therapy (for both external beams and brachytherapy) and in various diagnostic radiological examinations including mammography and CT dosimetry. For in vivo measurements, a probe of Al(2)O(3):C of size of a fraction of a millimeter provides the information on both the dose rate and the total dose from the readout of radioluminescence and OSL signals respectively, from the same probe. The availability of OSL dosimeters in various sizes and shapes and their performance characteristics as compared to established dosimeters such as plastic scintillation dosimeters, diode detectors, MOSFET detectors, radiochromic films, etc., shows that OSL may soon become the first choice for point dose measurements in clinical applications. A brief review of the recent developments is presented.

  18. Recent developments of optically stimulated luminescence materials and techniques for radiation dosimetry and clinical applications

    PubMed Central

    Pradhan, A. S.; Lee, J. I.; Kim, J. L.

    2008-01-01

    During the last 10 years, optically stimulated luminescence (OSL) has emerged as a formidable competitor not only to thermoluminescence dosimetry (TLD) but also to several other dosimetry systems. Though a large number of materials have been synthesized and studied for OSL, Al2O3:C continues to dominate the dosimetric applications. Re-investigations of OSL in BeOindicate that this material might provide an alternative to Al2O3:C. Study of OSL of electronic components of mobile phones and ID cards appears to have opened up a feasibility of dosimetry and dose reconstruction using the electronic components of gadgets of everyday use in the events of unforeseen situations of radiological accidents, including the event of a dirty bomb by terrorist groups. Among the newly reported materials, a very recent development of NaMgF3:Eu2+ appears fascinating because of its high OSL sensitivity and tolerable tissue equivalence. In clinical dosimetry, an OSL as a passive dosimeter could do all that TLD can do, much faster with a better or at least the same efficiency; and in addition, it provides a possibility of repeated readout unlike TLD, in which all the dose information is lost in a single readout. Of late, OSL has also emerged as a practical real-time dosimeter for in vivo measurements in radiation therapy (for both external beams and brachytherapy) and in various diagnostic radiological examinations including mammography and CT dosimetry. For in vivo measurements, a probe of Al2O3:C of size of a fraction of a millimeter provides the information on both the dose rate and the total dose from the readout of radioluminescence and OSL signals respectively, from the same probe. The availability of OSL dosimeters in various sizes and shapes and their performance characteristics as compared to established dosimeters such as plastic scintillation dosimeters, diode detectors, MOSFET detectors, radiochromic films, etc., shows that OSL may soon become the first choice for point dose measurements in clinical applications. A brief review of the recent developments is presented. PMID:19893698

  19. Technical Note: Precision and accuracy of a commercially available CT optically stimulated luminescent dosimetry system for the measurement of CT dose index

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vrieze, Thomas J.; Sturchio, Glenn M.; McCollough, Cynthia H.

    Purpose: To determine the precision and accuracy of CTDI{sub 100} measurements made using commercially available optically stimulated luminescent (OSL) dosimeters (Landaur, Inc.) as beam width, tube potential, and attenuating material were varied. Methods: One hundred forty OSL dosimeters were individually exposed to a single axial CT scan, either in air, a 16-cm (head), or 32-cm (body) CTDI phantom at both center and peripheral positions. Scans were performed using nominal total beam widths of 3.6, 6, 19.2, and 28.8 mm at 120 kV and 28.8 mm at 80 kV. Five measurements were made for each of 28 parameter combinations. Measurements weremore » made under the same conditions using a 100-mm long CTDI ion chamber. Exposed OSL dosimeters were returned to the manufacturer, who reported dose to air (in mGy) as a function of distance along the probe, integrated dose, and CTDI{sub 100}. Results: The mean precision averaged over 28 datasets containing five measurements each was 1.4%{+-} 0.6%, range = 0.6%-2.7% for OSL and 0.08%{+-} 0.06%, range = 0.02%-0.3% for ion chamber. The root mean square (RMS) percent differences between OSL and ion chamber CTDI{sub 100} values were 13.8%, 6.4%, and 8.7% for in-air, head, and body measurements, respectively, with an overall RMS percent difference of 10.1%. OSL underestimated CTDI{sub 100} relative to the ion chamber 21/28 times (75%). After manual correction of the 80 kV measurements, the RMS percent differences between OSL and ion chamber measurements were 9.9% and 10.0% for 80 and 120 kV, respectively. Conclusions: Measurements of CTDI{sub 100} with commercially available CT OSL dosimeters had a percent standard deviation of 1.4%. After energy-dependent correction factors were applied, the RMS percent difference in the measured CTDI{sub 100} values was about 10%, with a tendency of OSL to underestimate CTDI relative to the ion chamber. Unlike ion chamber methods, however, OSL dosimeters allow measurement of the radiation dose profile.« less

  20. Technical Note: Precision and accuracy of a commercially available CT optically stimulated luminescent dosimetry system for the measurement of CT dose index

    PubMed Central

    Vrieze, Thomas J.; Sturchio, Glenn M.; McCollough, Cynthia H.

    2012-01-01

    Purpose: To determine the precision and accuracy of CTDI100 measurements made using commercially available optically stimulated luminescent (OSL) dosimeters (Landaur, Inc.) as beam width, tube potential, and attenuating material were varied. Methods: One hundred forty OSL dosimeters were individually exposed to a single axial CT scan, either in air, a 16-cm (head), or 32-cm (body) CTDI phantom at both center and peripheral positions. Scans were performed using nominal total beam widths of 3.6, 6, 19.2, and 28.8 mm at 120 kV and 28.8 mm at 80 kV. Five measurements were made for each of 28 parameter combinations. Measurements were made under the same conditions using a 100-mm long CTDI ion chamber. Exposed OSL dosimeters were returned to the manufacturer, who reported dose to air (in mGy) as a function of distance along the probe, integrated dose, and CTDI100. Results: The mean precision averaged over 28 datasets containing five measurements each was 1.4% ± 0.6%, range = 0.6%–2.7% for OSL and 0.08% ± 0.06%, range = 0.02%–0.3% for ion chamber. The root mean square (RMS) percent differences between OSL and ion chamber CTDI100 values were 13.8%, 6.4%, and 8.7% for in-air, head, and body measurements, respectively, with an overall RMS percent difference of 10.1%. OSL underestimated CTDI100 relative to the ion chamber 21/28 times (75%). After manual correction of the 80 kV measurements, the RMS percent differences between OSL and ion chamber measurements were 9.9% and 10.0% for 80 and 120 kV, respectively. Conclusions: Measurements of CTDI100 with commercially available CT OSL dosimeters had a percent standard deviation of 1.4%. After energy-dependent correction factors were applied, the RMS percent difference in the measured CTDI100 values was about 10%, with a tendency of OSL to underestimate CTDI relative to the ion chamber. Unlike ion chamber methods, however, OSL dosimeters allow measurement of the radiation dose profile. PMID:23127052

  1. Technical note: precision and accuracy of a commercially available CT optically stimulated luminescent dosimetry system for the measurement of CT dose index.

    PubMed

    Vrieze, Thomas J; Sturchio, Glenn M; McCollough, Cynthia H

    2012-11-01

    To determine the precision and accuracy of CTDI(100) measurements made using commercially available optically stimulated luminescent (OSL) dosimeters (Landaur, Inc.) as beam width, tube potential, and attenuating material were varied. One hundred forty OSL dosimeters were individually exposed to a single axial CT scan, either in air, a 16-cm (head), or 32-cm (body) CTDI phantom at both center and peripheral positions. Scans were performed using nominal total beam widths of 3.6, 6, 19.2, and 28.8 mm at 120 kV and 28.8 mm at 80 kV. Five measurements were made for each of 28 parameter combinations. Measurements were made under the same conditions using a 100-mm long CTDI ion chamber. Exposed OSL dosimeters were returned to the manufacturer, who reported dose to air (in mGy) as a function of distance along the probe, integrated dose, and CTDI(100). The mean precision averaged over 28 datasets containing five measurements each was 1.4% ± 0.6%, range = 0.6%-2.7% for OSL and 0.08% ± 0.06%, range = 0.02%-0.3% for ion chamber. The root mean square (RMS) percent differences between OSL and ion chamber CTDI(100) values were 13.8%, 6.4%, and 8.7% for in-air, head, and body measurements, respectively, with an overall RMS percent difference of 10.1%. OSL underestimated CTDI(100) relative to the ion chamber 21∕28 times (75%). After manual correction of the 80 kV measurements, the RMS percent differences between OSL and ion chamber measurements were 9.9% and 10.0% for 80 and 120 kV, respectively. Measurements of CTDI(100) with commercially available CT OSL dosimeters had a percent standard deviation of 1.4%. After energy-dependent correction factors were applied, the RMS percent difference in the measured CTDI(100) values was about 10%, with a tendency of OSL to underestimate CTDI relative to the ion chamber. Unlike ion chamber methods, however, OSL dosimeters allow measurement of the radiation dose profile.

  2. WE-D-17A-06: Optically Stimulated Luminescence Detectors as ‘LET-Meters’ in Proton Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Granville, D; Sahoo, N; Sawakuchi, GO

    Purpose: To demonstrate and evaluate the potential of optically stimulated luminescence (OSL) detectors (OSLDs) for measurements of linear energy transfer (LET) in therapeutic proton beams. Methods: Batches of Al2O2:C OSLDs were irradiated with an absorbed dose of 0.2 Gy in un-modulated proton beams of varying LET (0.67 keV/μm to 2.58 keV/μm). The OSLDs were read using continuous wave (CW-OSL) and pulsed (P-OSL) stimulation modes. We parameterized and calibrated three characteristics of the OSL signals as functions of LET: CW-OSL curve shape, P-OSL curve shape and the ratio of the two OSL emission band intensities (ultraviolet/blue ratio). Calibration curves were createdmore » for each of these characteristics to describe their behaviors as functions of LET. The true LET values were determined using a validated Monte Carlo model of the proton therapy nozzle used to irradiate the OSLDs. We then irradiated batches of OSLDs with an absorbed dose of 0.2 Gy at various depths in two modulated proton beams (140 MeV, 4 cm wide spread-out Bragg peak (SOBP) and 250 MeV, 10 cm wide SOBP). The LET values were calculated using the OSL response and the calibration curves. Finally, measured LET values were compared to the true values determined using Monte Carlo simulations. Results: The CW-OSL curve shape, P-OSL curve shape and the ultraviolet/blue-ratio provided proton LET estimates within 12.4%, 5.7% and 30.9% of the true values, respectively. Conclusion: We have demonstrated that LET can be measured within 5.7% using Al2O3:C OSLDs in the therapeutic proton beams used in this investigation. From a single OSLD readout, it is possible to measure both the absorbed dose and LET. This has potential future applications in proton therapy quality assurance, particularly for treatment plans based on optimization of LET distributions. This research was partially supported by the Natural Sciences and Engineering Research Council of Canada.« less

  3. SU-C-16A-02: A Beryllium Oxide (BeO) Fibre-Coupled Luminescence Dosimeter for High Dose Rate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santos, A; Institute for Photonics and Advanced Sensing and School of Chem and Phys, Adelaide, South Australia; Mohammadi, M

    Purpose: Beryllium oxide (BeO) ceramics have an effective atomic number, zeff ∼7.1, closely matched to water, zeff ∼7.4. The purpose of this study was to evaluate the use of a beryllium oxide (BeO) ceramic fibrecoupled luminescence dosimeter, named RL/OSL BeO FOD, for high dose rate (HDR) brachytherapy dosimetry. In our dosimetry system the radioluminescence (RL) of BeO ceramics is utilized for dose-rate measurements, and the optically stimulated luminescence (OSL) can be read post exposure for accumulated dose measurements. Methods: The RL/OSL BeO FOD consists of a 1 mm diameter × 1 mm long cylinder of BeO ceramic coupled to amore » 15 m long silica-silica optical fibre. The optical fibre is connected to a custom developed portable RL and OSL reader, located outside of the treatment suite. The x-ray energy response was evaluated using superficial x-rays, an Ir-192 source and high energy linear accelerators. The RL/OSL BeO FOD was then characterised for an Ir-192 source, investigating the dose response and angular dependency. A depth dose curve for the Ir-192 source was also measured. Results: The RL/OSL BeO FOD shows an under-response at low energy x-rays as expected. Though at higher x-ray energies, the OSL response continued to increase, while the RL response remained relatively constant. The dose response for the RL is found to be linear up to doses of 15 Gy, while the OSL response becomes more supralinear to doses above 15 Gy. Little angular dependency is observed and the depth dose curve measured agreed within 4% of that calculated based on TG-43. Conclusion: This works shows that the RL/OSL BeO FOD can be useful in HDR dosimetry. With the RL/OSL BeO FODs current size, it is capable of being inserted into intraluminal catheters and interstitial needles to verify HDR treatments.« less

  4. TL and OSL studies of carbon doped magnesium aluminate (MgAl2O4:C)

    NASA Astrophysics Data System (ADS)

    Raj, Sanu S.; Mishra, D. R.; Soni, Anuj; Grover, V.; Polymeris, G. S.; Muthe, K. P.; Jha, S. K.; Tyagi, A. K.

    2016-10-01

    The MgAl2O4:C has been synthesized by using two different methods by electron gun and vacuum assisted melting of MgAl2O4 in presence of graphite. The MgAl2O4:C phosphor thus developed by these two different methods have similar types of the TL/OSL defects with multiple overlapping TL glow peaks from 100 °C to 400 °C. The Computerized Curve De-convolution Analysis (CCDA) has been used to measure TL parameters such as thermal trap depth, frequency factor and order of kinetic associated with charge transfer process in TL phenomenon. The investigated TL/OSL results show that these two methods of incorporating carbon in MgAl2O4 have generated closely resemble the defects of similar types in MgAl2O4:C lattice. However, the MgAl2O4:C synthesized by electron gun shows relatively larger concentration of the TL/OSL defects as compared to MgAl2O4:C synthesized using vacuum assisted melting method. The photo-ionization cross-section (PIC) associated with fastest OSL component of MgAl2O4: C is found to be ∼ 0.5 times than that of fastest OSL component of commercially available dosimetric grade α-Al2O3:C. The MgAl2O4:C thus developed shows good dynamic OSL dose linearity from few mGy to 1 Gy. This work reveals that MgAl2O4:C could be developed as potential tissue equivalent OSL / TL material.

  5. Fundamentals of Materials, Techniques, and Instrumentation for OSL and FNTD Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akselrod, M. S.

    The optically stimulated luminescence (OSL) technique has already become a successful commercial tool in personal radiation dosimetry, medical dosimetry, diagnostic imaging, geological and archeological dating. This review briefly describes the history and fundamental principles of OSL materials, methods and instrumentation. The advantages of OSL technology and instrumentation in comparison with thermoluminescent technique are analyzed. Progress in material and detector engineering has allowed new and promising developments regarding OSL applications in the medical field. Special attention is dedicated to Al{sub 2}O{sub 3}:C as a material of choice for many dosimetric applications. Different aspects of OSL theory, materials optical and dosimetric properties,more » instrumentation, and data processing algorithms are described. The next technological breakthrough was done with Fluorescent Nuclear Track Detectors (FNTD) that have some important advantages in measuring fast neutron and high energy heavy charge particles that have become the latest tool in radiation therapy. New Mg-doped aluminum oxide crystals and novel type of imaging instrumentation for FNTD technology are discussed with regard to application in mixed neutron-gamma fields, medical dosimetry and radiobiological research.« less

  6. Fundamentals of Materials, Techniques, and Instrumentation for OSL and FNTD Dosimetry

    NASA Astrophysics Data System (ADS)

    Akselrod, M. S.

    2011-05-01

    The optically stimulated luminescence (OSL) technique has already become a successful commercial tool in personal radiation dosimetry, medical dosimetry, diagnostic imaging, geological and archeological dating. This review briefly describes the history and fundamental principles of OSL materials, methods and instrumentation. The advantages of OSL technology and instrumentation in comparison with thermoluminescent technique are analyzed. Progress in material and detector engineering has allowed new and promising developments regarding OSL applications in the medical field. Special attention is dedicated to Al2O3:C as a material of choice for many dosimetric applications. Different aspects of OSL theory, materials optical and dosimetric properties, instrumentation, and data processing algorithms are described. The next technological breakthrough was done with Fluorescent Nuclear Track Detectors (FNTD) that have some important advantages in measuring fast neutron and high energy heavy charge particles that have become the latest tool in radiation therapy. New Mg-doped aluminum oxide crystals and novel type of imaging instrumentation for FNTD technology are discussed with regard to application in mixed neutron-gamma fields, medical dosimetry and radiobiological research.

  7. Study of optically stimulated luminescence in LiSrAlF6:Eu2+

    NASA Astrophysics Data System (ADS)

    More, Y. K.; Nikam, M. S.; Wankhede, S. P.; Moharil, S. V.

    2018-05-01

    In this context the results on beta induced thermoluminescence and optically stimulated luminescence properties of LiSrAlF6:Eu2+ are reported. Phosphor shows good luminescence properties for both thermal and optical stimulation. The continuous wave optically stimulated luminescence (CW-OSL) signal as recorded using blue (470 nm) stimulation was found to be 37 % that of standard phosphor Lithium Magnesium Phosphate. The phosphor shows linear response of CW-OSL for various exposures ranging from 20 mGy to 10 Gy with minimum detectable dose approximately equal to 13 µGy. About 20% reduction in the TL signal of the phosphor after OSL readout was observed. About 50% fading of OSL signal was observed within three days of irradiation out of which about 35% OSL signal depleted within a day after irradiation.

  8. The response of thermally and optically stimulated luminescence from Al2O3:C to high-energy heavy charged particles

    NASA Technical Reports Server (NTRS)

    Gaza, R.; Yukihara, E. G.; McKeever, S. W. S.

    2004-01-01

    The thermoluminescence (TL) and optically stimulated luminescence (OSL) response of Al2O3 dosimeters to high-energy heavy charged particles (HCP) has been studied using the heavy ion medical accelerator at Chiba, Japan. The samples were Al2O3 single-crystal chips, of the type usually known as TLD-500, and Luxel(TM) dosimeters (Al2O3:C powder in plastic) from Landauer Inc. The samples were exposed to 4He (150 MeV/u), 12C (400 MeV/u), 28Si (490 MeV/us) and 56Fe (500 MeV/u) ions, with linear energy transfer values covering the range from 2.26 to 189 keV/micrometers in water and doses from 1 to 100 mGy (to water). A 90Sr/90Y beta source, calibrated against a 60Co secondary standard, was used for calibration purposes. For OSL, we used both continuous-wave OSL measurements (CW-OSL, using green light stimulation at 525 nm) and pulsed OSL measurements (POSL, using 532 nm stimulation from a Nd:YAG Q-switched laser). The efficiencies (eta HCP, gamma) of the different HCPs at producing OSL or TL were observed to depend not only upon the linear energy transfer (LET) of the HCP, but also upon the sample type (single crystal chip or Luxel(TM)) and the luminescence method used to define the signal--i.e. TL, CW-OSL initial intensity, CW-OSL total area, or POSL. Observed changes in shape of the decay curve lead to potential methods for extracting LET information of unknown radiation fields. A discussion of the results is given, including the potential use of OSL from Al2O3 in the areas of space radiation dosimetry and radiation oncology. c2004 Elsevier Ltd. All rights reserved.

  9. The response of thermally and optically stimulated luminescence from Al2O3:C to high-energy heavy charged particles.

    PubMed

    Gaza, R; Yukihara, E G; McKeever, S W S

    2004-01-01

    The thermoluminescence (TL) and optically stimulated luminescence (OSL) response of Al2O3 dosimeters to high-energy heavy charged particles (HCP) has been studied using the heavy ion medical accelerator at Chiba, Japan. The samples were Al2O3 single-crystal chips, of the type usually known as TLD-500, and Luxel(TM) dosimeters (Al2O3:C powder in plastic) from Landauer Inc. The samples were exposed to 4He (150 MeV/u), 12C (400 MeV/u), 28Si (490 MeV/us) and 56Fe (500 MeV/u) ions, with linear energy transfer values covering the range from 2.26 to 189 keV/micrometers in water and doses from 1 to 100 mGy (to water). A 90Sr/90Y beta source, calibrated against a 60Co secondary standard, was used for calibration purposes. For OSL, we used both continuous-wave OSL measurements (CW-OSL, using green light stimulation at 525 nm) and pulsed OSL measurements (POSL, using 532 nm stimulation from a Nd:YAG Q-switched laser). The efficiencies (eta HCP, gamma) of the different HCPs at producing OSL or TL were observed to depend not only upon the linear energy transfer (LET) of the HCP, but also upon the sample type (single crystal chip or Luxel(TM)) and the luminescence method used to define the signal--i.e. TL, CW-OSL initial intensity, CW-OSL total area, or POSL. Observed changes in shape of the decay curve lead to potential methods for extracting LET information of unknown radiation fields. A discussion of the results is given, including the potential use of OSL from Al2O3 in the areas of space radiation dosimetry and radiation oncology. c2004 Elsevier Ltd. All rights reserved.

  10. Effect of high-dose irradiation on the optically stimulated luminescence of Al2O3:C

    NASA Technical Reports Server (NTRS)

    Yukihara, E. G.; Whitley, V. H.; McKeever, S. W. S.; Akselrod, A. E.; Akselrod, M. S.

    2004-01-01

    This paper examines the effect of high-dose irradiation on the optically stimulated luminescence (OSL) of Al2O3:C, principally on the shape of the OSL decay curve and on the OSL sensitivity. The effect of the degree of deep trap filling on the OSL was also studied by monitoring the sensitivity changes after doses of beta irradiation and after step-annealing of samples previously irradiated with high doses. The OSL response to dose shows a linear-supralinear-saturation behavior, with a decrease in the response for doses higher than those required for saturation. This behavior correlates with the sensitivity changes observed in the samples annealed only to 773 K, which show sensitization for doses up to 20-50 Gy and desensitization for higher doses. Data from the step-annealing study leads to the suggestion that the sensitization is caused by the filling of deep electron traps, which become thermally unstable at 1100-1200 K, whereas the desensitization is caused by the filling of deep hole traps, which become thermally unstable at 800-875 K, along with a concomitant decrease in the concentration of recombination centers (F+ -centers). Changes in the shape of the OSL decay curves are also observed at high doses, the decay becoming faster as the dose increases. These changes in the OSL decay curves are discussed in terms of multiple overlapping components, each characterized by different photoionization cross-sections. However, using numerical solutions of the rate equations for a simple model consisting of a main trap and a recombination center, it is shown that the kinetics of OSL process may also be partially responsible for the changes in the OSL curves at high doses in Al2O3:C. Finally, the implication of these results for the dosimetry of heavy charged particles is discussed. c2004 Elsevier Ltd. All rights reserved.

  11. Thermally-assisted optically stimulated luminescence from deep electron traps in α-Al2O3:C,Mg

    NASA Astrophysics Data System (ADS)

    Kalita, J. M.; Chithambo, M. L.; Polymeris, G. S.

    2017-07-01

    We report thermally-assisted optically stimulated luminescence (TA-OSL) in α-Al2O3:C,Mg. The OSL was measured at elevated temperatures between 50 and 240 °C from a sample preheated to 500 °C after irradiation to 100 Gy. That OSL could be measured even after the preheating is direct evidence of the existence of deep electron traps in α-Al2O3:C,Mg. The TA-OSL intensity goes through a peak with measurement temperature. The initial increase is ascribed to thermal assistance to optical stimulation whereas the subsequent decrease in intensity is deduced to reflect increasing incidences of non-radiative recombination, that is, thermal quenching. The activation energy for thermal assistance corresponding to a deep electron trap was estimated as 0.667 ± 0.006 eV whereas the activation energy for thermal quenching was calculated as 0.90 ± 0.04 eV. The intensity of the TA-OSL was also found to increase with irradiation dose. The dose response is sublinear from 25 to 150 Gy but saturates with further increase of dose. The TA-OSL dose response has been discussed by considering the competition for charges at the deep traps. This study incidentally shows that TA-OSL can be effectively used in dosimetry involving large doses.

  12. Extending the upper age limit for luminescence dating using the thermally transferred optically stimulated luminescence signal from quartz

    NASA Astrophysics Data System (ADS)

    Duller, Geoff A. T.; Wintle, Ann G.

    2010-05-01

    The optically stimulated luminescence (OSL) signal from quartz has been exploited for the last 20 years to date heated and unheated materials. While methods based on this signal have been extremely successful and are now widely adopted in laboratories around the world, growth of the signal with dose is affected by saturation and this commonly limits application to samples with equivalent doses of ~100 to 300 Gy. In most environments this limits application of the method to the last 100-150 ka. Studies of OSL from quartz in the late 1980's showed that if the OSL signal from a sample was reduced to background level by measurement, and the sample then heated, further optical stimulation gave a significant signal. This recuperated OSL was viewed as a problem to be avoided, particularly for young samples. Three years ago papers were published showing that this recuperated signal has the potential to be valuable in dosimetry, and in particular that the signal continues to grow to doses in excess of 10,000 Gy offering the possibility of extending the age range over which quartz can be used to as much as 1 Ma. The first work on this signal was undertaken on fine grain quartz extracted from Chinese loess, and ages back to the Brunhes-Matuyama boundary were obtained. The signal is now commonly referred to as thermally transferred optically stimulated luminescence (TT-OSL). Intense research on the signal has focussed on a number of areas, including, (a) understanding the origin of the charge measured in TT-OSL, (b) improving methods for measuring the TT-OSL signal, and (c) developing protocols for using TT-OSL in dose estimation, and these are reviewed in this presentation.

  13. Luminescence properties of Eu{sup 2+} doped SrB{sub 4}O{sub 7} phosphor for radiation dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palan, C.B., E-mail: chetanpalan27@yahoo.in; Bajaj, N.S.; Omanwar, S.K.

    Highlights: • Report TL/OSL properties of SrB{sub 4}O{sub 7}:Eu{sup 2+} under beta irradiations. • OSL Sensitivity was about 33% than that of commercially available α-Al{sub 2}O{sub 3.} • TL glow peaks was appear at 305° C and TL sensitivity about 200 times higher than TLD-500. • OSL decay pattern was faster than α- Al{sub 2}O{sub 3}:C and dose response was linear nature. - Abstract: In this report, we presented the TL/OSL properties of Eu doped SrB{sub 4}O{sub 7} phosphor under β-irradiation. This phosphor was synthesized by using solid state method. The phosphor shows OSL sensitivity about 33% than that ofmore » commercially available α-Al{sub 2}O{sub 3}: C phosphor. CW-OSL curve possess two components having photoionization cross-sections 0.707 × 10{sup −17} and 18.58 × 10{sup −17} cm{sup 2} respectively and TL sensitivity about 200 times higher than TLD-500. The kinetic parameters such as activation energy, frequency factor and order of kinetics of TL curve were calculated by using peak shape method. In TL/OSL mode dose-response was almost linear in the range of measurements. The MDD was found to be 1.26 mGy with 3σ of background. Also reusability studies showed the phosphor can be reused for 10 cycles with 1% change in the OSL output. The PL spectra of SrB{sub 4}O{sub 7} showed emission in NUV region when excited with 318 nm under UV source.« less

  14. Detection of sub micro Gray dose levels using OSL phosphor LiMgPO4:Tb,B

    NASA Astrophysics Data System (ADS)

    Rawat, N. S.; Dhabekar, Bhushan; Muthe, K. P.; Koul, D. K.; Datta, D.

    2017-04-01

    Detection of sub micro Gray doses finds application in personnel and environmental monitoring, and nuclear forensics. Recently developed LiMgPO4:Tb,B (LMP) is highly sensitive Optically Stimulated Luminescence (OSL) phosphor with excellent dosimetric properties. The OSL emission spectrum of LMP consists of several peaks attributed to characteristic Tb3+ emission. The OSL emission peak at 380 nm is favorable for bi-alkali PMT used in RISO reader system. It is demonstrated that significant improvement in dose detection threshold can be realized for LMP by optimization of continuous wave (CW-) OSL parameters like stimulation intensity and readout time. The minimum measurable dose (MMD) as low as 0.49 μGy in readout time of less than 1 s at stimulation intensity of 32 mW/cm2 has been achieved using this phosphor. The recommendations for choice of parameters for personnel and environmental monitoring are also discussed.

  15. INTEGRATED CIRCUITS FROM MOBILE PHONES AS POSSIBLE EMERGENCY OSL/TL DOSIMETERS.

    PubMed

    Sholom, S; McKeever, S W S

    2016-09-01

    In this article, optically stimulated luminescence (OSL) data are presented from integrated circuits (ICs) extracted from mobile phones. The purpose is to evaluate the potential of using OSL from components in personal electronic devices such as smart phones as a means of emergency dosimetry in the event of a large-scale radiological incident. ICs were extracted from five different makes and models of mobile phone. Sample preparation procedures are described, and OSL from the IC samples following irradiation using a (90)Sr/(90)Y source is presented. Repeatability, sensitivity, dose responses, minimum measureable doses, stability and fading data were examined and are described. A protocol for measuring absorbed dose is presented, and it was concluded that OSL from these components is a viable method for assessing dose in the days following a radiological incident. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Optically stimulated luminescence of borate glasses containing magnesia, quicklime, lithium and potassium carbonates

    NASA Astrophysics Data System (ADS)

    Valença, J. V. B.; Silveira, I. S.; Silva, A. C. A.; Dantas, N. O.; Antonio, P. L.; Caldas, L. V. E.; d'Errico, F.; Souza, S. O.

    2017-11-01

    The OSL characteristics of three different borate glass matrices containing magnesia (LMB), quicklime (LCB) or potassium carbonate (LKB) were examined. Five different formulations for each composition were produced using a melt-quenching method and analyzed in terms of both dose-response curves and OSL shape decay. The samples were irradiated using a 90Sr/90Y beta source with doses up to 30 Gy. Dose-response curves were plotted using the initial OSL intensity as the chosen parameter. The OSL analysis showed that LKB glasses are the most sensitive to beta irradiation. For the most sensitive LKB composition, the irradiation process was also done using a 60Co gamma source in a dose range from 200 to 800 Gy. In all cases, no saturation was observed. A fitting process using a three-term exponential function was performed for the most sensitive formulations of each composition, which suggested a similar behavior in the OSL decay.

  17. Abrupt sand-dune accumulation at the northeastern margin of the Tibetan Plateau challenges the wet MIS3a inferred from numerous lake-highstands

    PubMed Central

    Long, Hao; Fuchs, Markus; Yang, Linhai; Cheng, Hongyi

    2016-01-01

    Over the Tibetan Plateau and adjacent regions, numerous 14C-based lake records revealed a ubiquitous wet climatic period during 40–25 ka (late MIS 3), which is in contradiction with the global pattern of generally cold and dry climates. This paper focuses on OSL dating results of a large set of sand dunes and alluvial sediments (50 OSL ages) from the Qinwangchuan (QWC) Basin at the northeast edge of the Tibetan Plateau, with the aim to test the validity of the anomalous wet condition for the late MIS 3 interval, evidenced by numerous lake highstands. The abrupt sand dune accumulation as indication of increased aridity in the study area was OSL dated to ~40–13 ka. This dry climatic inference of the sand dune system from QWC apparently shows no wet MIS 3a event. Thus, the anomalous wet conditions revealed by high lake levels for the late MIS 3 phase may not be a universal phenomena across entire western China. PMID:27172907

  18. OSL technique for studies of jasper samples

    NASA Astrophysics Data System (ADS)

    Teixeira, Maria Inês; Caldas, Linda V. E.

    2014-02-01

    Jasper samples (green, red, brown, ocean and striped) were studied in relation to their optically stimulated luminescence (OSL) dosimetric properties, in this work. Since 2000, the radiation metrology group of IPEN has studied different stones as new materials for application in high-dose dosimetry. The jasper samples were exposed to different radiation doses, using the Gamma-cell 220 system (60Co) of IPEN. Calibration curves were obtained for the jasper samples between 50 Gy and 300 kGy. The reproducibility of the OSL response and the lower detection doses were determined. All five types of jasper samples showed their usefulness as irradiation indicators and as high-dose dosimeters, using the OSL technique.

  19. Comparison of Cottonwood Dendrochronology and Optically Stimulated Luminescence Geochronometers Along a High Plains Meandering River, Powder River, Montana, USA

    NASA Astrophysics Data System (ADS)

    Hasse, T. R.; Schook, D. M.

    2017-12-01

    Geochronometers at centennial scales can aid our understanding of process rates in fluvial geomorphology. Plains cottonwood trees (Populus deltoides ssp. Monilifera) in the high plains of the United States are known to germinate on freshly created deposits such as point bars adjacent to rivers. As the trees mature they may be partially buried (up to a few meters) by additional flood deposits. Cottonwood age gives a minimum age estimate of the stratigraphic surface where the tree germinated and a maximum age estimate for overlying sediments, providing quantitative data on rates of river migration and sediment accumulation. Optically Stimulated Luminescence (OSL) of sand grains can be used to estimate the time since the sand grains were last exposed to sunlight, also giving a minimum age estimate of sediment burial. Both methods have disadvantages: Browsing, partial burial, and other damage to young cottonwoods can increase the time required for the tree to reach a height where it can be sampled with a tree corer, making the germination point a few years to a few decades older than the measured tree age; fluvial OSL samples can have inherited age (when the OSL age is older than the burial age) if the sediment was not completely bleached prior to burial. We collected OSL samples at 8 eroding banks of the Powder River Montana, and tree cores at breast height (±1.2 m) from cottonwood trees growing on the floodplain adjacent to the OSL sample locations. Using the Minimum Age Model (MAM) we found that OSL ages appear to be 500 to 1,000 years older than the adjacent cottonwood trees which range in age (at breast height) from 60 to 185 years. Three explanations for this apparent anomaly in ages are explored. Samples for OSL could be below a stratigraphic unconformity relative to the cottonwood germination elevation. Shallow samples for OSL could be affected by anthropogenic mixing of sediments due to plowing and leveling of hay fields. The OSL samples could have significant inherited ages due to partial bleaching during sediment transport in this high plains river with high suspended sediment loads. The dendrochronology of the adjacent cottonwood trees then offers an independent measurement of the inherited age of the OSL samples.

  20. MgO:Li,Ce,Sm as a high-sensitivity material for Optically Stimulated Luminescence dosimetry

    NASA Astrophysics Data System (ADS)

    Oliveira, Luiz C.; Yukihara, Eduardo G.; Baffa, Oswaldo

    2016-04-01

    The goal of this work was to investigate the relevant dosimetric and luminescent properties of MgO:Li3%,Ce0.03%,Sm0.03%, a newly-developed, high sensitivity Optically Stimulated Luminescence (OSL) material of low effective atomic number (Zeff = 10.8) and potential interest for medical and personal dosimetry. We characterized the thermoluminescence (TL), OSL, radioluminescence (RL), and OSL emission spectrum of this new material and carried out a preliminary investigation on the OSL signal stability. MgO:Li,Ce,Sm has a main TL peak at ~180 °C (at a heating rate of 5 °C/s) associated with Ce3+ and Sm3+ emission. The results indicate that the infrared (870 nm) stimulated OSL from MgO:Li,Ce,Sm has suitable properties for dosimetry, including high sensitivity to ionizing radiation (20 times that of Al2O3:C, under the measurement conditions) and wide dynamic range (7 μGy-30 Gy). The OSL associated with Ce3+ emission is correlated with a dominant, practically isolated peak at 180 °C. Fading of ~15% was observed in the first hour, probably due to shallow traps, followed by subsequent fading of 6-7% over the next 35 days. These properties, together with the characteristically fast luminescence from Ce3+, make this material also a strong candidate for 2D OSL dose mapping.

  1. MgO:Li,Ce,Sm as a high-sensitivity material for Optically Stimulated Luminescence dosimetry

    PubMed Central

    Oliveira, Luiz C.; Yukihara, Eduardo G.; Baffa, Oswaldo

    2016-01-01

    The goal of this work was to investigate the relevant dosimetric and luminescent properties of MgO:Li3%,Ce0.03%,Sm0.03%, a newly-developed, high sensitivity Optically Stimulated Luminescence (OSL) material of low effective atomic number (Zeff = 10.8) and potential interest for medical and personal dosimetry. We characterized the thermoluminescence (TL), OSL, radioluminescence (RL), and OSL emission spectrum of this new material and carried out a preliminary investigation on the OSL signal stability. MgO:Li,Ce,Sm has a main TL peak at ~180 °C (at a heating rate of 5 °C/s) associated with Ce3+ and Sm3+ emission. The results indicate that the infrared (870 nm) stimulated OSL from MgO:Li,Ce,Sm has suitable properties for dosimetry, including high sensitivity to ionizing radiation (20 times that of Al2O3:C, under the measurement conditions) and wide dynamic range (7 μGy–30 Gy). The OSL associated with Ce3+ emission is correlated with a dominant, practically isolated peak at 180 °C. Fading of ~15% was observed in the first hour, probably due to shallow traps, followed by subsequent fading of 6–7% over the next 35 days. These properties, together with the characteristically fast luminescence from Ce3+, make this material also a strong candidate for 2D OSL dose mapping. PMID:27076349

  2. Including Deposition Rate in Models of Cosmogenic Nuclide Accumulation in Fluvial Sediments to Improve Terrace Abandonment Ages

    NASA Astrophysics Data System (ADS)

    Norton, K. P.; Wang, N.; Van Dissen, R. J.; Little, T.

    2017-12-01

    Fluvial sediments are archives of the erosional, transport, and depositional processes occurring in the catchment. Terraces become robust markers for geomorphic analysis if their time of abandonment can be determined. Methods such as OSL can determine burial ages for fine grained sediments within the terrace fill but may not be directly related to the terrace abandonment age. Cosmogenic nuclides can be used to determine exposure ages for geologically young terraces but the surface being dated may have been subsequently eroded and the material itself may have been deposited with an inherited nuclide concentration. To deal with this problem, many researchers collect multiple samples with depth to model the depth-dependent nuclide concentration to help constrain inheritance and post-depositional erosion. It is often, however, assumed that the entire sediment pile accumulated instantaneously. In this submission, we present the results of a depth profile model that incorporates sediment accumulation rate to improve terrace age estimates. We test this model on fault-offset river terraces near Kaikoura, New Zealand. We measured depth profiles of OSL ages and cosmogenic nuclide concentrations of two late Quaternary terraces that are offset by up to 800 m across the Kekerengu Fault. OSL ages and dated tephras in the overlying loess provide minimum age constraints for both terraces while OSL ages of fine-grained sediments within the fill provide depositional ages. The predicted sedimentation rates for the terraces are as high as 0.5m/yr, consistent with geologically instantaneous deposition. Modelled abandonment ages from cosmogenic nuclides for the terraces are consistent with OSL and tephra constraints at 9.7 +/- 3.8 ka and 30.4 +/- 2.1 ka, respectively. These terrace abandonment ages yield dextral slip rates of 18.5-20.5 mm/yr and 25-28 mm/yr, respectively, consistent with the rapid slip rate on the adjacent Hope Fault.

  3. SU-E-T-264: Preliminary Results On New Optically Stimulated Luminescent Materials for Proton Therapy Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doull, B; Zheng, Y; Procure Proton Therapy Center, Oklahoma City, OK

    2014-06-01

    Purpose: The objective of this work is to test the premise that luminescence materials with less under-response to proton beams can be identified by testing their dose response to low-LET radiation. The goal is to develop new Optically Stimulated Luminescence (OSL) materials with improved response for proton therapy dosimetry. Methods: We first measured the dose response of new OSL materials, synthesized in our laboratory, to low-LET radiation (beta rays from a {sup 90}Sr/{sup 90}Y source) and selected two materials having different OSL saturation characteristics and good dosimetric properties, namely MgB4O7:Ce,Li and MgO:Li. Commercial Al2O3:C was also used for comparison. Thesemore » materials were then irradiated at several depths along a pristine proton beam. The luminescence responses of the materials, relative to the entrance response, were compared with the depth dose profile measured by a multiple-layer ion chamber. Results: The OSL signals of MgB4O7:Ce,Li and MgO:Li were characterized for signal stability, dose response, and response to a clinical proton beam. The materials were also compared with the commercial Al2O3:C. The signals from both MgB4O7:Ce,Li and MgO:Li were relatively stable after a one day delay following irradiation. The low-LET dose response of the materials showed that, over the dose range investigated (up to ∼800 Gy), MgB4O7:Ce,Li did not saturate, whereas MgO:Li and Al2O3:C saturated at doses of ∼100 Gy. MgB4O7:Ce,Li showed less underresponse to proton beams than MgO:Li and Al2O3:C. Conclusion: In general the material with the highest saturation doses for low-LET radiation (MgB4O7:Ce,Li) showed the least under-response to proton beams, which suggests that it may be possible to develop better OSL materials for proton dosimetry if the dose response can be controlled during synthesis. Nevertheless, the degree in which the response to proton beams can be controlled remains to be determined. The research is funded by the Oklahoma Center for the Advancement of Science and Technology (OCAST), project number HR12-055.« less

  4. Investigation of a BeO-based optically stimulated luminescence dosemeter.

    PubMed

    Sommer, M; Henniger, J

    2006-01-01

    The optical sensitivity of BeO-based luminophors has been well-known for many years. The optical stimulation of BeO with blue light is most effective. Then the dosemeters emit luminescent light in the ultraviolet-range around 325 nm. Matched on these facts a simple optically stimulated luminescence (OSL) treatment has been developed. Intense blue light-emitting diodes are used for cw-stimulation. A Hamamatsu solar blind photomultiplier detects the OSL-light. Good separation of both spectral ranges by optical filters is very important. The dosemeter has a linear dose response between approximately 20 muGy and >10 Gy. It was suggested, that a modification of stimulation conditions would allow measurements down to 1 muGy. Fading, photon energy dependence and reproducibility of OSL-signal correspond well with requirements to clinical and personal dosemeters. In addition, basic questions of the OSL-process in BeO have been investigated. A relevant point of interest was the dependency of the OSL-signal on stimulation power.

  5. Highly sensitive Europium doped SrSO4 OSL nanophosphor for radiation dosimetry applications

    NASA Astrophysics Data System (ADS)

    Patle, Anita; Patil, R. R.; Kulkarni, M. S.; Bhatt, B. C.; Moharil, S. V.

    2015-10-01

    Highly sensitive Europium doped SrSO4 optically stimulated luminescent (OSL) phosphor was developed by synthesizing a nano phosphor which is treated at 1000 °C. Excellent OSL properties are observed in the developed phosphor and the sensitivity is found to be 1.26 times to that of the commercial Al2O3:C (Landauer Inc.) phosphor based on area integration method. The sample showed a single TL glow peak around 230 °C which is found to reduce by 47% after the OSL readout. Sublinear dose response with the saturation around 100 mGy is observed in this sample which suggests that it is extremely sensitive and hence will be suitable in detecting very low dose levels. Minimum measurable dose on the used set up is estimated to be 1.42 μGy. Practically no fading is observed for first ten days and the phosphor has excellent reusability. High sensitivity, low fading, excellent reusability will make this phosphor suitable for radiation dosimetry applications using OSL.

  6. Improving the AOAC use-dilution method by establishing a minimum log density value for test microbes on inoculated carriers.

    PubMed

    Tomasino, Stephen F; Pines, Rebecca M; Hamilton, Martin A

    2009-01-01

    The AOAC Use-Dilution methods, 955.14 (Salmonella enterica), 955.15 (Staphylococcus aureus), and 964.02 (Pseudomonas aeruginosa), are used to measure the efficacy of disinfectants on hard inanimate surfaces. The methods do not provide procedures to assess log density of the test microbe on inoculated penicylinders (carrier counts). Without a method to measure and monitor carrier counts, the associated efficacy data may not be reliable and repeatable. This report provides a standardized procedure to address this method deficiency. Based on carrier count data collected by four laboratories over an 8 year period, a minimum log density value is proposed to qualify the test results. Carrier count data were collected concurrently with 242 Use-Dilution tests. The tests were conducted on products bearing claims against P. aeruginosa and S. aureus with and without an organic soil load (OSL) added to the inoculum (as specified on the product label claim). Six carriers were assayed per test for a total of 1452 carriers. All 242 mean log densities were at least 6.0 (geometric mean of 1.0 x 10(6) CFU/carrier). The mean log densities did not exceed 7.5 (geometric mean of 3.2 x 10(7) CFU/carrier). For all microbes and OSL treatments, the mean log density (+/- SEM) was 6.7 (+/- 0.07) per carrier (a geometric mean of 5.39 x 10(6) CFU/carrier). The mean log density for six carriers per test showed good repeatability (0.29) and reproducibility (0.32). A minimum mean log density of 6.0 is proposed as a validity requirement for S. aureus and P. aeruginosa. The minimum level provides for the potential inherent variability that may be experienced by a wide range of laboratories and the slight effect due to the addition of an OSL. A follow-up report is planned to present data to support the carrier count procedure and carrier counts for S. enterica.

  7. Luminescence dating of ancient Darhad basin, Mongolia

    NASA Astrophysics Data System (ADS)

    Cheul Kim, Jin; Yi, Sangheon; Lim, Jaesoo; Kim, Ju-Yong

    2016-04-01

    Darhad basin is located in the northern Mongolia, in the western end of the Baikal Rift Zone. In contrast to the neighboring Lake Hovsgol, Mongolia's largest and deepest lake, the Darhad is a drained lake basin. It is ~100 km long (north-south), 20-40 km wide and covered by sediments which locally exceed 500 m thickness (Zorin et al., 1989). Darhad basin is characterized by alternating episodes of expansion and desiccation that are closely related with the Pleistocene damming events. Previous studies of the Darhad Basin suggest that the last paleolake was dammed by a large glacier or the sediments (Selivanov, 1967, 1968; Krivonogov et al., 2005; Gillespie et al., 2008). Especially, recent expansion of the paleolake might be caused by the two glacial maxima during MIS 4 and 2. However, glacier-dammed lakes might be short-lived, dried up and permafrost occurred in the drained basin during the Holocene period. The uppermost paleolake sediments (13.2 m depth) are exposed following the curvature of the meandering river (called "Hodon outcrop"). It is considered the most likely site for the youngest paleolake sediments because it is distributed in the northern middle part of the paleolake. Krivonogov et al. 2012 described the Hodon outcrop with the sedimentological and chronological data. Age dating of 16 samples (11 mollusk shells, 5 wood fragments) indicated that Hodon outcrop sediments were deposited between 10.1±7 and 4.9±5 ka. However, the ages obtained on shells much older dates than the matched wood samples because of ingestion of old carbon by mollusks. The age difference between shells and wood fragments is a minimum of 1.73 ka and a maximum of 3.41 ka (average 2.5 ka). In this case, 14C ages from shells should be corrected with appropriate correction factor. However, the old carbon effects could vary temperally and spatially in the Darhad paleolake. The limited number of the 14C ages from wood fragments result in a simple linear trend in the depth-age curve. Thus, age control on existing 14C ages from this site is limited, chronological interpretation based on the 14C ages is still incomplete in Hodon outcrop sediments. OSL (Optically Stimulated Luminescence) is an alternative method for dating to overcome the problems associated with 14C methods. OSL has been extensively used for dating arctic sediments (Thomas et al., 2006; more). Previous optical ages on Darhad paleolake sediments obtained using IRSL (Infrared-stimulated luminescence) on feldspars (Gillespie et al., 2008; Batbaatar et al., 2009). Feldspar has much brighter luminescence than quartz, while the OSL signal of feldspars bleaches at least one order of magnitude slower than the OSL signal of quartz (Godfrey-Smith et al., 1988; Huntly and Lamothe, 2001; Mauz and Bungenstock, 2007; Kim et al., 2012). In glaciofluvial, glaciolacustrine environments, inadequate bleaching of the OSL signal is known to be a potential problem of burial ages (Thomas et al., 2006). OSL dating of permafrost deposits may also involve uncertainty about the inhomogeneous radiation field surrounding the dosimeter and the absorption of ionizing energy alternately by water and ice in a not-constant pore volume (Haeberli et al., 2003). In this study, we test the applicability of quartz OSL dating for the uppermost paleolake sediments in the Hodon outcrop of the Darhad basin. The OSL results were systematically compared with additional radiocarbon ages from wood fragments to conclude the reliability of the OSL dates and to construct intensive chronology for Late-Pleistocene Darhad paleolake. To evaluate the time of recent expansion of the paleolake, the northern piedmont (Talyn outcrop) of the basin was dated by OSL.

  8. 1997 NRL Review

    DTIC Science & Technology

    1997-04-01

    are subsequently read out using a low- doped Glasses power, solid-state diode laser. Figure 4 shows a schematic of the OSL dosimeter . The 807-nm A.L...Huston, S, Rychnovsky, and B.L. Justus (near infrared) diode laser light stimulates blue OSL Optical Sciences Division emission from the dosimeter , and...The sensitivity of the hole pairs become trapped and may persist until prototype OSL dosimeter exceeds that of the stimulated to luminesce by the

  9. Direct evidence for the participation of band-tails and excited-state tunnelling in the luminescence of irradiated feldspars

    NASA Astrophysics Data System (ADS)

    Poolton, N. R. J.; Kars, R. H.; Wallinga, J.; Bos, A. J. J.

    2009-12-01

    The significance and extent of band-tail states in the luminescence and dosimetry properties of natural aluminosilicates (feldspars) is investigated by means of studies using low temperature (10 K) irradiation and optically stimulated luminescence (OSL) stimulation spectroscopy, and thermoluminescence (TL) in the range 10-200 K, made in comparison with high temperature (300 K) irradiation and photo-transferred OSL and TL investigations undertaken at low temperature. These measurements allow mappings of the band-tails to be made; they are found to be ~0.4 eV in extent in the typical materials studied. Furthermore, by populating charge trapping centres at high temperature (300 K) and monitoring the OSL stimulation spectra at temperatures in the range 10-300 K, clear evidence is presented for the presence of both thermally activated and non-thermally activated OSL processes; it is argued that the former result from thermally activated hopping through the band-tail states, whilst the latter are due to tunnelling processes, either from the excited state of the OSL centres or through the tail states. The spectral measurements are supported by analysis of the temporal dependence of the OSL signals, which correspond to either tunnelling or general order kinetic decay processes.

  10. All is not lost: deriving a top-down mass budget of plastic at sea

    NASA Astrophysics Data System (ADS)

    Koelmans, Albert A.; Kooi, Merel; Lavender Law, Kara; van Sebille, Erik

    2017-11-01

    Understanding the global mass inventory is one of the main challenges in present research on plastic marine debris. Especially the fragmentation and vertical transport processes of oceanic plastic are poorly understood. However, whereas fragmentation rates are unknown, information on plastic emissions, concentrations of plastics in the ocean surface layer (OSL) and fragmentation mechanisms is available. Here, we apply a systems engineering analytical approach and propose a tentative ‘whole ocean’ mass balance model that combines emission data, surface area-normalized plastic fragmentation rates, estimated concentrations in the OSL, and removal from the OSL by sinking. We simulate known plastic abundances in the OSL and calculate an average whole ocean apparent surface area-normalized plastic fragmentation rate constant, given representative radii for macroplastic and microplastic. Simulations show that 99.8% of the plastic that had entered the ocean since 1950 had settled below the OSL by 2016, with an additional 9.4 million tons settling per year. In 2016, the model predicts that of the 0.309 million tons in the OSL, an estimated 83.7% was macroplastic, 13.8% microplastic, and 2.5% was < 0.335 mm ‘nanoplastic’. A zero future emission simulation shows that almost all plastic in the OSL would be removed within three years, implying a fast response time of surface plastic abundance to changes in inputs. The model complements current spatially explicit models, points to future experiments that would inform critical model parameters, and allows for further validation when more experimental and field data become available.

  11. The Influence of Added Mass on Optimal Step Length in Running.

    PubMed

    Reenalda, Jasper; Maas, Maurice T F; de Koning, Jos J

    2016-10-01

    To examine the influence of induced changes in the morphology of the leg by adding mass on the optimal step length (OSL) in experienced runners to get more insight into parameters that influence preferred step length (PSL) and OSL. Thirteen experienced male runners (mean age 26.9 ± 6.1 y, height 183.7 ± 7.1 cm, mass 71.8 ± 5.9 kg) ran on a treadmill in 3 different conditions: unloaded (UL), loaded with 2 kg mass at the ankles (MA), and loaded with 2 kg mass at the hips (MH) at 7 different step lengths (SLs). SL deviations were expressed as deviations in relative leg length (%LL) from the individual PSL: 0%LL, ±5%LL, ±10%LL, and ±15%LL. Trials lasted 8 min, and 8 min of rest was given between trials. Oxygen uptake (V̇O 2 ) was expressed as a fraction of V̇O 2 at PSL + 0%LL in the unloaded condition (%V̇O 2 ). The %SL with the lowest value of %V̇O 2 was considered the OSL for this group of participants. OSL at the UL condition was 6% shorter than PSL. The MA condition resulted in a 7%LL larger OSL than at UL and MH (P < .05). The mass distribution of the leg is a determinant of the OSL. As a consequence of the added mass to the ankles, OSL was 7%LL longer. Morphological characteristics of the leg might therefore play an important role in determining the runner's individual optimal SL.

  12. Impedance measurements of the human cochlear partition

    NASA Astrophysics Data System (ADS)

    Raufer, Stefan; Nakajima, Hideko H.

    2018-05-01

    The cochlea is a mechanical frequency analyzer, owing its characteristics to the impedance of the cochlear partition. In humans, the impedance of the partition has not been measured directly, and estimates of the stiffness (a principal component of the impedance) are based on loose assumptions. In this study, we examine not only the stiffness of the basilar membrane (BM), but also the osseous spiral lamina (OSL), which, in human, vibrates substantially. We hypothesize that the OSL contributes significantly to the volume stiffness of the cochlear partition (CP). We measured velocities of the BM and OSL at different radial locations 1 mm from the base of the cochlea in a fresh human cadaveric specimen. Simultaneously, we measured intracochlear pressures on the other side of the partition, in scala vestibuli. With the velocity and pressure measurements we can estimate the specific acoustic impedance of the BM and OSL (Z = p/v). At frequencies well below the resonant frequency, the stiffness of these structures can be extracted by multiplying the impedance by the radian frequency. The specific acoustic stiffness was found to be 1.2 GPa/m on the BM, 6 GPa/m at the juncture where the BM attaches to the OSL, and 10 GPa/m at the midpoint of the OSL. A beam model, appropriate to model the radial motion of the BM in guinea pig or gerbil, cannot describe the displacement of the human CP in the base. Instead, we find that the OSL is hinged near the modiolus and vibrates significantly near the connection to the more compliant BM, contributing greatly the volume compliance of the CP.

  13. The effect of pre-dose on thermally and optically stimulated luminescence from α-Al2O3:C,Mg and α-Al2O3:C.

    PubMed

    Kalita, J M; Chithambo, M L

    2018-06-15

    We report the effect of pre-dose on the thermoluminescence (TL) and optically stimulated luminescence (OSL) dose response of α-Al 2 O 3 :C,Mg and α-Al 2 O 3 :C. Before any luminescence measurement, the samples were irradiated with different doses, namely 100, 500 and 1000 Gy to populate the deep electron traps. This is the pre-dose. The results from TL and OSL studies are compared with results from samples used without any pre-measurement dose. The TL glow curves and OSL decay curves of α-Al 2 O 3 :C,Mg recorded after pre-doses of 100, 500 and 1000 Gy are identical to those from a sample used without any pre-dose. Further, the TL and OSL dose response of all α-Al 2 O 3 :C,Mg samples are similar regardless of pre-dose. In comparison, the TL glow curves and OSL decay curves of α-Al 2 O 3 :C are influenced by pre-dose. We conclude that the differences in the TL and OSL dose response of various pre-dosed samples of α-Al 2 O 3 :C are due to the concentration of charge in the deep traps. On the other hand, owing to the lower concentration of such deep traps in α-Al 2 O 3 :C,Mg, the TL or OSL dose responses are not affected by pre-dose in this material. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. SU-F-18C-09: Assessment of OSL Dosimeter Technology in the Validation of a Monte Carlo Radiation Transport Code for CT Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carver, D; Kost, S; Pickens, D

    Purpose: To assess the utility of optically stimulated luminescent (OSL) dosimeter technology in calibrating and validating a Monte Carlo radiation transport code for computed tomography (CT). Methods: Exposure data were taken using both a standard CT 100-mm pencil ionization chamber and a series of 150-mm OSL CT dosimeters. Measurements were made at system isocenter in air as well as in standard 16-cm (head) and 32-cm (body) CTDI phantoms at isocenter and at the 12 o'clock positions. Scans were performed on a Philips Brilliance 64 CT scanner for 100 and 120 kVp at 300 mAs with a nominal beam width ofmore » 40 mm. A radiation transport code to simulate the CT scanner conditions was developed using the GEANT4 physics toolkit. The imaging geometry and associated parameters were simulated for each ionization chamber and phantom combination. Simulated absorbed doses were compared to both CTDI{sub 100} values determined from the ion chamber and to CTDI{sub 100} values reported from the OSLs. The dose profiles from each simulation were also compared to the physical OSL dose profiles. Results: CTDI{sub 100} values reported by the ion chamber and OSLs are generally in good agreement (average percent difference of 9%), and provide a suitable way to calibrate doses obtained from simulation to real absorbed doses. Simulated and real CTDI{sub 100} values agree to within 10% or less, and the simulated dose profiles also predict the physical profiles reported by the OSLs. Conclusion: Ionization chambers are generally considered the standard for absolute dose measurements. However, OSL dosimeters may also serve as a useful tool with the significant benefit of also assessing the radiation dose profile. This may offer an advantage to those developing simulations for assessing radiation dosimetry such as verification of spatial dose distribution and beam width.« less

  15. Surface dose measurements with commonly used detectors: a consistent thickness correction method.

    PubMed

    Reynolds, Tatsiana A; Higgins, Patrick

    2015-09-08

    The purpose of this study was to review application of a consistent correction method for the solid state detectors, such as thermoluminescent dosimeters (chips (cTLD) and powder (pTLD)), optically stimulated detectors (both closed (OSL) and open (eOSL)), and radiochromic (EBT2) and radiographic (EDR2) films. In addition, to compare measured surface dose using an extrapolation ionization chamber (PTW 30-360) with other parallel plate chambers RMI-449 (Attix), Capintec PS-033, PTW 30-329 (Markus) and Memorial. Measurements of surface dose for 6MV photons with parallel plate chambers were used to establish a baseline. cTLD, OSLs, EDR2, and EBT2 measurements were corrected using a method which involved irradiation of three dosimeter stacks, followed by linear extrapolation of individual dosimeter measurements to zero thickness. We determined the magnitude of correction for each detector and compared our results against an alternative correction method based on effective thickness. All uncorrected surface dose measurements exhibited overresponse, compared with the extrapolation chamber data, except for the Attix chamber. The closest match was obtained with the Attix chamber (-0.1%), followed by pTLD (0.5%), Capintec (4.5%), Memorial (7.3%), Markus (10%), cTLD (11.8%), eOSL (12.8%), EBT2 (14%), EDR2 (14.8%), and OSL (26%). Application of published ionization chamber corrections brought all the parallel plate results to within 1% of the extrapolation chamber. The extrapolation method corrected all solid-state detector results to within 2% of baseline, except the OSLs. Extrapolation of dose using a simple three-detector stack has been demonstrated to provide thickness corrections for cTLD, eOSLs, EBT2, and EDR2 which can then be used for surface dose measurements. Standard OSLs are not recommended for surface dose measurement. The effective thickness method suffers from the subjectivity inherent in the inclusion of measured percentage depth-dose curves and is not recommended for these types of measurements.

  16. SU-E-T-91: Correction Method to Determine Surface Dose for OSL Detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reynolds, T; Higgins, P

    Purpose: OSL detectors are commonly used in clinic due to their numerous advantages, such as linear response, negligible energy, angle and temperature dependence in clinical range, for verification of the doses beyond the dmax. Although, due to the bulky shielding envelope, this type of detectors fails to measure skin dose, which is an important assessment of patient ability to finish the treatment on time and possibility of acute side effects. This study aims to optimize the methodology of determination of skin dose for conventional accelerators and a flattening filter free Tomotherapy. Methods: Measurements were done for x-ray beams: 6 MVmore » (Varian Clinac 2300, 10×10 cm{sup 2} open field, SSD = 100 cm) and for 5.5 MV (Tomotherapy, 15×40 cm{sup 2} field, SAD = 85 cm). The detectors were placed at the surface of the solid water phantom and at the reference depth (dref=1.7cm (Varian 2300), dref =1.0 cm (Tomotherapy)). The measurements for OSLs were related to the externally exposed OSLs measurements, and further were corrected to surface dose using an extrapolation method indexed to the baseline Attix ion chamber measurements. A consistent use of the extrapolation method involved: 1) irradiation of three OSLs stacked on top of each other on the surface of the phantom; 2) measurement of the relative dose value for each layer; and, 3) extrapolation of these values to zero thickness. Results: OSL measurements showed an overestimation of surface doses by the factor 2.31 for Varian 2300 and 2.65 for Tomotherapy. The relationships: SD{sup 2300} = 0.68 × M{sup 2300}-12.7 and SDτoμo = 0.73 × Mτoμo-13.1 were found to correct the single OSL measurements to surface doses in agreement with Attix measurements to within 0.1% for both machines. Conclusion: This work provides simple empirical relationships for surface dose measurements using single OSL detectors.« less

  17. Characterization of a fiber-coupled Al2O3:C luminescence dosimetry system for online in vivo dose verification during 192Ir brachytherapy.

    PubMed

    Andersen, Claus E; Nielsen, Søren Kynde; Greilich, Steffen; Helt-Hansen, Jakob; Lindegaard, Jacob Christian; Tanderup, Kari

    2009-03-01

    A prototype of a new dose-verification system has been developed to facilitate prevention and identification of dose delivery errors in remotely afterloaded brachytherapy. The system allows for automatic online in vivo dosimetry directly in the tumor region using small passive detector probes that fit into applicators such as standard needles or catheters. The system measures the absorbed dose rate (0.1 s time resolution) and total absorbed dose on the basis of radioluminescence (RL) and optically stimulated luminescence (OSL) from aluminum oxide crystals attached to optical fiber cables (1 mm outer diameter). The system was tested in the range from 0 to 4 Gy using a solid-water phantom, a Varian GammaMed Plus 192Ir PDR afterloader, and dosimetry probes inserted into stainless-steel brachytherapy needles. The calibrated system was found to be linear in the tested dose range. The reproducibility (one standard deviation) for RL and OSL measurements was 1.3%. The measured depth-dose profiles agreed well with the theoretical expectations computed with the EGSNRC Monte Carlo code, suggesting that the energy dependence for the dosimeter probes (relative to water) is less than 6% for source-to-probe distances in the range of 2-50 mm. Under certain conditions, the RL signal could be greatly disturbed by the so-called stem signal (i.e., unwanted light generated in the fiber cable upon irradiation). The OSL signal is not subject to this source of error. The tested system appears to be adequate for in vivo brachytherapy dosimetry.

  18. Development and demonstration of 2D dosimetry using optically stimulated luminescence from new Al2O3 films for radiotherapy applications

    NASA Astrophysics Data System (ADS)

    Ahmed, Md Foiez

    Scope and Method of Study: The goal of this work was to develop and demonstrate a 2D dosimetry system based on the optically stimulated luminescence (OSL) from new Al2O3 films for radiotherapy applications. A 2D laser-scanning system was developed for the readout and two OSL films (Al2O3:C and Al2O3:C,Mg) were tested. A dose reconstruction algorithm addressing corrections required for the characteristic material properties and the properties related to the system design was developed. The dosimetric properties of the system were tested using clinical X-ray (6 MV) beam. The feasibility of small field dosimetry was tested using heavy ion beams (221 MeV proton and 430 MeV 12C beam). For comparison, clinical tests were performed with ionization chamber, diode arrays and the commercial radiochromic films (Gafchromic EBT3) when applicable. Findings and Conclusions: The results demonstrate that the developed image reconstruction algorithm enabled > 300x faster laser-scanning readout of the Al2O3 films, eliminating the restriction imposed by its slow luminescence decay. The algorithm facilitates submillimeter spatial resolution, reduces the scanner position dependence (of light collection efficiency) and removes the inherent galvo geometric distortion, among other corrections. The system has a background signal < 1 mGy, linearity correction factor of < 10% up to ˜4.0 Gy and < 2% dose uncertainty over the clinically relevant dose range of 0.1 - 30 Gy. The system has a dynamic range of 4 - 5 orders, only limited by PMT linearity. The absolute response from Al2O2:C films is higher than Al2O 2:C,Mg films, but with lower image signal-to-noise ratio due to lower concentration of fast F+-center emission. As a result, Al2O2:C,Mg films are better suited than Al2O3:C films for small field dosimetry, which requires precise dosimetry with sub-millimeter spatial resolution. The dose uncertainty associated with OSL film dosimetry is lower than that associated with EBT3 film dosimetry due to lower background, simpler calibration and wider dynamic range. In conclusion, this work demonstrates excellent potentials of the 2D OSL dosimetry system for both relative and absolute dosimetry in radiotherapy applications, with especial emphasis on small fields.

  19. An Analysis of Emergency Department Overcrowding at The Johns Hopkins Hospital

    DTIC Science & Technology

    2001-06-20

    Jefferson 3rd floor (JEF3), Medical Care Progressive Unit ( MPC4 ), Nelson 4th floor (NEL4), Osler 4th floor (OSL4), Osler 5th floor (OSL5), and Osler...ranged from a low of 73.78% for OSL5 to a high of 94.60% for JEF3. The LOS for the DOM units ranged from 2.89 days for HAL5 to 10.39 days for MPC4

  20. SU-E-T-592: OSL Response of Al2O3:C Detectors Exposed to Therapeutic Proton Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Granville, DA; Flint, DB; Sawakuchi, GO

    Purpose: To characterize the response of Al{sub 2}O{sub 3}:C optically stimulated luminescence (OSL) detectors (OSLDs) exposed to therapeutic proton beams of differing beam quality. Methods: We prepared Al{sub 2}O{sub 3}:C OSLDs from the same material as commercially available nanoDot dosimeters (Landauer, Inc). We irradiated the OSLDs in modulated proton beams of varying quality, as defined by the residual range. An absorbed dose to water of 0.2 Gy was delivered to all OSLDs with the residual range values varying from 0.5 to 23.5 cm (average LET in water from ∼0.5 to 2.5 keV/µm). To investigate the beam quality dependence of differentmore » emission bands within the OSL spectrum, we performed OSLD readouts using both continuous-wave stimulation (CW-OSL) and pulsed stimulation (P-OSL) with two sets of optical filters (Hoya U-340 and Kopp 5113). For all readout modes, the relative absorbed dose sensitivity ( S{sub rel}) for each beam quality was calculated using OSLDs irradiated in a 6 MV photon beam as a reference. Results: We found that the relative absorbed dose sensitivity was highly dependent on both readout mode and integration time of the OSL signal. For CW-OSL signals containing only the blue emission band, S{sub rel} was between 0.85 and 0.94 for 1 s readouts and between 0.82 and 0.93 for 10 s readouts. Similarly, for P-OSL readouts containing only the blue emission band S{sub rel} ranged from 0.86 to 0.91, and 0.82 to 0.93 for 1 s and 10 s readouts, respectively. For OSLD signals containing only the UV emission band, S{sub rel} ranged from 1.00 to 1.46, and 0.97 to 1.30 for P-OSL readouts of 1 s and 10 s, respectively. Conclusion: For measurements of absorbed dose using Al{sub 2}O{sub 3}:C OSLDs in therapeutic proton beams, dependence on beam quality was smallest for readout protocols that selected the blue emission band with small integration times. DA Granville received financial support from the Natural Sciences and Engineering Research Council of Canada.« less

  1. Use of OSL dating to establish the stratigraphic framework of Quaternary eolian sediments, Anton scarp upper trench, Northeastern Colorado High Plains, USA

    USGS Publications Warehouse

    Mahan, S.A.; Noe, D.C.; McCalpin, J.P.

    2009-01-01

    This paper contains the results of the optically stimulated luminescence (OSL) dating used to establish stratigraphic ages and relationships of eolian sediments in a trench in northeastern Colorado, USA. This trench was located in the upper face of the Anton scarp, a major topographic lineament trending NW-SE for a distance of 135 km, in anticipation of intersecting near-surface faulting. The trench was 180 m long, 4.5-6.0 m deep, and exposed 22 m of stratigraphic section, most of which dipped gently west and was truncated by gulley channeling at the face of the scarp. No direct evidence of faulting was found in the upper trench. The stratigraphy from the trench was described, mapped and dated using OSL on quartz and potassium feldspar, and 14C obtained from woody material. OSL dating identified two upper loess units as Peoria Loess and Gilman Canyon Loess, deposited between 16 and 30 ka ago. The bottom layers of the trench were substantially older, giving OSL ages in excess of 100 ka. These older ages are interpreted as underestimates, owing to saturation of the fast component of OSL. Using OSL and 14C dating, we can constrain the erosion and down cutting of the scarp face as occurring between 16 and 5.7 ka. As the trenching investigation continues in other parts of the scarp face, the results of this preliminary study will be of importance in relating the ages of the strata that underlie different parts of the scarp, and in determining whether Quaternary faulting was a mechanism that contributed to the formation of this regional geomorphic feature.

  2. Magnetic resonance imaging, ultrasonography and histology of the suspensory ligament origin: a comparative study of normal anatomy of warmblood horses.

    PubMed

    Bischofberger, A S; Konar, M; Ohlerth, S; Geyer, H; Lang, J; Ueltschi, G; Lischer, C J

    2006-11-01

    The diagnosis of lameness caused by proximal metacarpal and metatarsal pain can be challenging. Magnetic resonance imaging (MRI) offers the possibility for further diagnosis but there have been no studies on the normal MRI appearance of the origin of the suspensory ligament (OSL) in conjunction with ultrasonography and histology. To describe the MRI appearance of the OSL in fore- and hindlimbs of sound horses and compare it to the ultrasonographic and histological appearance. The findings can be used as reference values to recognise pathology in the OSL. The OSL in the fore- and hindlimbs of 6 sound horses was examined by ultrasonography prior to death, and MRI and histology post mortem. Qualitative evaluation and morphometry of the OSL were performed and results of all modalities compared. Muscular tissue, artefacts, variable SL size and shape complicated ultrasonographic interpretation. In MRI and histology the forelimb OSL consisted of 2 portions, the lateral being significantly thicker than medial. The hindlimb SL had a single large area of origin. In fore- and hindlimbs, the amount of muscular tissue was significantly larger laterally than medially. Overall SL measurements using MRI were significantly higher than using histology and ultrasonography and histological higher than ultrasonographic measurements. Morphologically, there was a good correlation between MRI and histology. MRI provides more detailed information than ultrasonography regarding muscle fibre detection and OSL dimension and correlates morphologically well with histology. Therefore, ultrasonographic results should be regarded with caution. MRI may be a diagnostic aid when other modalities fail to identify clearly the cause of proximal metacarpal and metatarsal pain; and may improve selection of adequate therapy and prognosis for injuries in this region.

  3. Influence of carbon on the thermoluminescence and optically stimulated luminescence of α-Al2O3:C crystals

    NASA Astrophysics Data System (ADS)

    Yang, Xin-Bo; Li, Hong-Jun; Bi, Qun-Yu; Cheng, Yan; Tang, Qiang; Xu, Jun

    2008-12-01

    α-Al2O3:C crystal shows excellent thermoluminescence (TL) and optically stimulated luminescence (OSL) properties but the real role carbon plays in this crystal is still not clearly understood so far. In this work, α-Al2O3:C crystal doping with different amounts of carbon were grown by the temperature gradient technique, and TL and OSL properties of as-grown crystals were investigated. Additionally, a mechanism was proposed to explain the role of carbon in forming the TL and OSL properties of α-Al2O3:C. TL and OSL intensities of as-grown crystals increase with the increasing amount of carbon doping in the crystal, but no shift is found in the glow peak location at 465 K. As the amount of carbon doping in the crystals decreases, OSL decay rate becomes faster. With the increase in heating rate, the integral TL response of as-grown crystals decreases and glow peak shifts to higher temperatures. TL response decrease rate increases with the increasing amount of carbon doping in the crystals. All the TL and OSL response curves of as-grown crystals show linear-sublinear-saturation characteristic, and OSL dose response exhibits higher sensitivity and wider linear dose range than that of TL. The crystal doping with 5000 ppm carbon shows the best dosimetric properties. Carbon plays the role of a dopant in α-Al2O3:C crystal and four-valent carbon anions replace the two-valent anions of oxygen during the crystal growth process, and large amounts of oxygen vacancies were formed, which corresponds to the high absorption coefficient of F and F+ centers in the crystals.

  4. An Efficient, Affordable Optically Stimulated Luminescent (OSL) Annealer.

    PubMed

    Abraham, Sara A; Frank, Samuel J; Kearfott, Kimberlee J

    2017-07-01

    Optically stimulated luminescent (OSL) dosimeters are devices used for measuring doses of ionizing radiation. Signal is stored within an OSL material so that when stimulated with light, light of a specific wavelength is emitted in proportion to the integrated ionizing radiation dose. Each interrogation of the material results in the loss of a small fraction of signal, thus allowing multiple interrogations leading to more accurate measurements of dose. In order to reuse a dosimeter, the residual signals from prior doses must be taken into account and subtracted from current readings, adding uncertainty to any future measurements. To reduce these errors when they become large, it is desirable to completely clear the stored signal or anneal the dosimeter. Traditionally, heating the material has accomplished this. In a commercially available dosimeter badge system, the OSL material Al2O3:C is incorporated into a plastic slide that would melt at the necessary high temperatures, which can reach 900 °C, required for annealing. Fortunately, due to the material's high sensitivity to light, OSLs can be optically annealed instead. In order to do this, an affordable OSL dosimeter annealer was designed with inexpensive, exchangeable blue, green, and white high intensity light-emitting diodes (LEDs). Several dosimeters were repeatedly annealed for recorded intervals and then read out. A single dosimeter was partially annealed through repeated interrogations with the LED array from a commercial reader. The signal loss due to the exposure to each light was analyzed to determine the practicality and efficiency of each color. The rate and extent of signal loss was dependent not only on the spectrum of annealing light but on the initial signal levels as well. These findings suggest that blue LEDs are the most promising for effective and rapid clearing of the OSL material Al2O3:C.

  5. Synthesis and evaluation of new antimalarial analogues of quinoline alkaloids derived from Cinchona ledgeriana Moens ex Trimen.

    PubMed

    Park, Byeoung-Soo; Kim, Dae-Young; Rosenthal, Philip J; Huh, Sun-Chul; Lee, Belinda J; Park, Eun -u; Kim, Sung-Min; Kim, Jang-Eok; Kim, Mi-Hee; Huh, Tae-Lin; Choi, Young-Jae; Suh, Ki-Hyung; Choi, Won-Sik; Lee, Sung-Eun

    2002-05-20

    In the course of attempts to develop antimalarial drugs, we have designed and synthesized a series of quinoline alkaloide derivatives. Three of them, N-(4-methoxy-3,5-di-tert-butylbenzyl)cinchonidinium bromide (OSL-5), O-benzyl-N-(3,5-di-tert-butyl-4-methoxybenzyl)cinchonidinium bromide (OSL-7), and N-(3,5-di-tert-butyl-4-methoxybenzyl)quininium bromide (OSL-14) show potent activity against Plasmodium falciparum.

  6. Quartz OSL Dating of the loess deposit in the eastern Tibetan Plateau and its environment implications since the Last Glaciation

    NASA Astrophysics Data System (ADS)

    Yang, S.; Cheng, T.; Liu, W.; Fang, X.

    2017-12-01

    Loess deposit is widespread in the Chuanxi Plateau, the eastern Tibetan Plateau, which is a critical archive for understanding the aeolian process, the evolution of the westerly and the environment changes on the Plateau. Previous studies have shown its aeolian origin, and mainly transported by wind from the western part of the Tibetan Plateau. However, the aeolian processes of the loess and its environment implications are not well understood mainly due to lack of detailed age controls. We carry out a combined quartz optically stimulated luminescence (OSL) dating and accelerator mass spectrometry radiocarbon dating (AMS 14-C) for the loess deposits in Garzê and Jinchuan. The results indicate that the quartz OSL dating can provide reliable age controls for the loess-paleosol sequences from the Chuanxi Plateau, showing the potential of OSL to date loess in the high altitude region. The results indicate that the OSL ages are in agreement with the observed stratigraphy in the field. The constructed OSL and AMS 14-C chronology of the Garzê loess reveals that the widespread loess in Ganzi Region deposited since the Last Glacial. The dust accumulation is rapid during marine isotope stage (MIS) 3 and 2, and a relative low accumulation rate in the Holocene, which may related with the desertification processes of the inner Tibetan Plateau.

  7. Reconstruction of settlement phases at Intermediate Bronze Age structures in the Negev Highlands (Israel) using luminescence dating

    NASA Astrophysics Data System (ADS)

    Junge, Andrea; Lomax, Johanna; Shahack-Gross, Ruth; Dunseth, Zachary C.; Finkelstein, Israel; Fuchs, Markus

    2016-04-01

    OSL dating is usually applied to sediments in paleoenvironmental sciences. However, there is only limited experience with determining the age of archaeological stone structures by OSL using dust deposits associated with these structures. The age of trapped dust deposits may be used to date the onset of settlement (sediment below structures), settlement activity (occupation layer), or the time after settlement (sediment between collapsed walls and roofs). In this study, OSL dating is applied for establishing a chronology of settlement structures situated in the Negev Highlands, Israel. Two archaeological sites are investigated to identify the occupation history, by dating the aeolian dust trapped within the remains of ancient buildings. OSL dating techniques are applied using coarse grain quartz and a standard SAR protocol. First results indicate that the luminescence properties of the trapped sediments are suitable for OSL dating. Therefore, it was possible to date the onset of sedimentation in a later phase of the human occupation or shortly after the settlement was abandoned, which is supported by archaeological evidence gained from pottery finds and the architecture of the buildings.

  8. In-Situ Dating on Mars: The Potential of OSL Dating

    NASA Technical Reports Server (NTRS)

    Blair, M. W.; Kalchgruber, R.; Yukihara, E. G.; Bulur, E.; Kim, S. S.; McKeever, W. S.

    2004-01-01

    More and more evidence is being accumulated that Mars has experienced aeolian, fluvial, and periglacial activity in the (relatively) recent past [1, 2, 3]. However, the temporal scale on which these processes took place is very poorly constrained since crater counting has errors comparable to the age for younger terrains (approx. 1 Ma). Consequently, many researchers have called for methods to establish the climatic and geomorphic history of Mars [4]. Lepper and McKeever [5] suggested developing optically stimulated luminescence (OSL) dating techniques for in-situ dating of martian sediments. Electron paramagnetic resonance (EPR) is closely related to OSL and could easily be incorporated on the same instrument platform [6]. These two methods can aid in developing a geological and climatic history of Mars over the last approx. one million years. Since the initial investigations, work has been carried out to develop OSL instrumentation and dating procedures that are suitable to the unique challenges of the martian environment. In this paper, we highlight the advances made in this project, focusing on OSL dating principles, assumptions, and procedures.

  9. Correlation of basic TL, OSL and IRSL properties of ten K-feldspar samples of various origins

    NASA Astrophysics Data System (ADS)

    Sfampa, I. K.; Polymeris, G. S.; Pagonis, V.; Theodosoglou, E.; Tsirliganis, N. C.; Kitis, G.

    2015-09-01

    Feldspars stand among the most widely used minerals in dosimetric methods of dating using thermoluminescence (TL), optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL). Having very good dosimetric properties, they can in principle contribute to the dating of every site of archaeological and geological interest. The present work studies basic properties of ten naturally occurring K-feldspar samples belonging to three feldspar species, namely sanidine, orthoclase and microcline. The basic properties studied are (a) the influence of blue light and infrared stimulation on the thermoluminescence glow-curves, (b) the growth of OSL, IRSL, residual TL and TL-loss as a function of OSL and IRSL bleaching time and (c) the correlation between the OSL and IRSL signals and the energy levels responsible for the TL glow-curve. All experimental data were fitted using analytical expressions derived from a recently developed tunneling recombination model. The results show that the analytical expressions provide excellent fits to all experimental results, thus verifying the tunneling recombination mechanism in these materials and providing valuable information about the concentrations of luminescence centers.

  10. Replacing the Orchestra? – The Discernibility of Sample Library and Live Orchestra Sounds

    PubMed Central

    Wolf, Anna; Platz, Friedrich; Mons, Jan

    2016-01-01

    Recently, musical sounds from pre-recorded orchestra sample libraries (OSL) have become indispensable in music production for the stage or popular charts. Surprisingly, it is unknown whether human listeners can identify sounds as stemming from real orchestras or OSLs. Thus, an internet-based experiment was conducted to investigate whether a classic orchestral work, produced with sounds from a state-of-the-art OSL, could be reliably discerned from a live orchestra recording of the piece. It could be shown that the entire sample of listeners (N = 602) on average identified the correct sound source at 72.5%. This rate slightly exceeded Alan Turing's well-known upper threshold of 70% for a convincing, simulated performance. However, while sound experts tended to correctly identify the sound source, participants with lower listening expertise, who resembled the majority of music consumers, only achieved 68.6%. As non-expert listeners in the experiment were virtually unable to tell the real-life and OSL sounds apart, it is assumed that OSLs will become more common in music production for economic reasons. PMID:27382932

  11. On the use of new generation mobile phone (smart phone) for retrospective accident dosimetry

    NASA Astrophysics Data System (ADS)

    Lee, J. I.; Chang, I.; Pradhan, A. S.; Kim, J. L.; Kim, B. H.; Chung, K. S.

    2015-11-01

    Optically stimulated luminescence (OSL) characteristics of resistors, inductors and integrated-circuit (IC) chips, extracted from new generation smart phones, were investigated for the purpose of retrospective accident dosimetry. Inductor samples were found to exhibit OSL sensitivity about 5 times and 40 times higher than that of the resistors and the IC chips, respectively. On post-irradiation storage, the resistors exhibited a much higher OSL fading (about 80 % in 36 h as compared to the value 3 min after irradiation) than IC chips (about 20 % after 36 h) and inductors (about 50 % in 36 h). Higher OSL sensitivity, linear dose response (from 8.7 mGy up to 8.9 Gy) and acceptable fading make inductors more attractive for accident dosimetry than widely studied resistors.

  12. Determination of transmission factors for beta radiation using Al 2O 3:C commercial OSL dosimeters

    NASA Astrophysics Data System (ADS)

    Pinto, T. N. O.; Caldas, L. V. E.

    2010-07-01

    In recent years, the optically stimulated luminescence (OSL) technique has been used in personal dosimetry, and aluminum oxide (Al 2O 3:C) has become a very useful material for this technique. The objective of this work was the determination of the transmission factors for beta radiation using Al 2O 3:C commercial dosimeters and the OSL method. The obtained results were similar to the transmission factors reported in the beta source calibration certificates.

  13. In Vitro Partial-Body Dose Assessment Using a Radiation Responsive Protein Biomarker

    DTIC Science & Technology

    2005-01-01

    would design and evaluate the dosimetry of the murine in vivo partial-body irradiation set-up. Thermo-luminescent dosimeter (TLD) chips or Optically...Stimulated Luminescent ( OSL ) should be placed near the mice in the plexiglass tubes in order to measure the dose profile to the mice. GAFCHROMIC...TLDs) chips or ( OSLs ) will be placed near the mice in the Plexiglas tubes in order to measure the dose to the mice. TLDs or OSLs will be placed

  14. An Assessment of the Shipboard Training Effectiveness of the Integrated Damage Control Training Technology (IDCTT) Version 3.0

    DTIC Science & Technology

    1998-03-01

    damage control actions in an assigned area of the ship. Reports are received from the On Scene Leader ( OSL ) and Investigators. Simultaneously, the RPL...control location. A phone talker and plotter will perform in unison with their counterparts in DCC. Key members of the repair party, the OSL and...the obligation of the On Scene Leader ( OSL ). This experienced petty officer is tasked with directing the ATL’s actions and informing the RPL of repair

  15. Using new luminescence methods to date the Palaeolithic: the example of Kalambo Falls

    NASA Astrophysics Data System (ADS)

    Duller, Geoff; Tooth, Stephen; Barham, Larry

    2013-04-01

    The Palaeolithic site of Kalambo Falls in the north of Zambia was the subject of detailed study by J.D. Clark in the 1950s with 4 excavations being located within 1 km of each other in a basin upstream of the falls. A rich palaeolithic tool record was recovered, but the value of this record was limited by the lack of chronological information available. In 2006, one of the excavation sites was re-investigated (Barham et al., 2009), including examination of the stratigraphic context and collection of samples for luminescence dating. Many of the sediments in the Kalambo basin were deposited by fluvial activity. Dose distributions in the single grain quartz optically stimulated luminescence (OSL) measurements of the youngest sediments are consistent with incomplete bleaching. However, the residual doses obtained are typically less than 10 Gy, and so for older sediments the impact of incomplete bleaching becomes insignificant. The oldest samples are affected by a different problem, namely saturation of the OSL signal, and many grains are saturated. However in all cases some grains give finite equivalent dose values, making it feasible to calculate single grain quartz OSL ages, but it is difficult to assess whether these ages are reliable or not. Thermally transferred OSL (TT-OSL) from quartz is able to date much older samples due to the high saturation dose of this signal (Duller and Wintle, 2012). Comparison of the TT-OSL and OSL demonstrates that the OSL signal yields age underestimates as samples near saturation. Only by using the two luminescence methods is it possible to create an absolute chronology for this key site stretching back over half a million years. This study demonstrates the potential of using these two luminescence signals together for dating Palaeolithic sites throughout Africa and beyond. Barham, L., Duller, G. A. T., Plater, A. J., Tooth, S. and Turner, S. (2009). Recent excavations at Kalambo Falls, Zambia. Antiquity 83(322). Duller, G. A. T. and Wintle, A. G. (2012). The potential of the thermally transferred optically stimulated luminescence signal from quartz for dating sediments. Quaternary Geochronology 7: 6-20.

  16. Surface dose measurements with commonly used detectors: a consistent thickness correction method

    PubMed Central

    Higgins, Patrick

    2015-01-01

    The purpose of this study was to review application of a consistent correction method for the solid state detectors, such as thermoluminescent dosimeters (chips (cTLD) and powder (pTLD)), optically stimulated detectors (both closed (OSL) and open (eOSL)), and radiochromic (EBT2) and radiographic (EDR2) films. In addition, to compare measured surface dose using an extrapolation ionization chamber (PTW 30‐360) with other parallel plate chambers RMI‐449 (Attix), Capintec PS‐033, PTW 30‐329 (Markus) and Memorial. Measurements of surface dose for 6 MV photons with parallel plate chambers were used to establish a baseline. cTLD, OSLs, EDR2, and EBT2 measurements were corrected using a method which involved irradiation of three dosimeter stacks, followed by linear extrapolation of individual dosimeter measurements to zero thickness. We determined the magnitude of correction for each detector and compared our results against an alternative correction method based on effective thickness. All uncorrected surface dose measurements exhibited overresponse, compared with the extrapolation chamber data, except for the Attix chamber. The closest match was obtained with the Attix chamber (−0.1%), followed by pTLD (0.5%), Capintec (4.5%), Memorial (7.3%), Markus (10%), cTLD (11.8%), eOSL (12.8%), EBT2 (14%), EDR2 (14.8%), and OSL (26%). Application of published ionization chamber corrections brought all the parallel plate results to within 1% of the extrapolation chamber. The extrapolation method corrected all solid‐state detector results to within 2% of baseline, except the OSLs. Extrapolation of dose using a simple three‐detector stack has been demonstrated to provide thickness corrections for cTLD, eOSLs, EBT2, and EDR2 which can then be used for surface dose measurements. Standard OSLs are not recommended for surface dose measurement. The effective thickness method suffers from the subjectivity inherent in the inclusion of measured percentage depth‐dose curves and is not recommended for these types of measurements. PACS number: 87.56.‐v PMID:26699319

  17. Characterization of Al2O3 optically stimulated luminescence films for 2D dosimetry using a 6 MV photon beam

    NASA Astrophysics Data System (ADS)

    Ahmed, M. F.; Shrestha, N.; Schnell, E.; Ahmad, S.; Akselrod, M. S.; Yukihara, E. G.

    2016-11-01

    This work evaluates the dosimetric properties of newly developed optically stimulated luminescence (OSL) films, fabricated with either Al2O3:C or Al2O3:C,Mg, using a prototype laser scanning reader, a developed image reconstruction algorithm, and a 6 MV therapeutic photon beam. Packages containing OSL films (Al2O3:C and Al2O3:C,Mg) and a radiochromic film (Gafchromic EBT3) were irradiated using a 6 MV photon beam using different doses, field sizes, with and without wedge filter. Dependence on film orientation of the OSL system was also tested. Diode-array (MapCHECK) and ionization chamber measurements were performed for comparison. The OSLD film doses agreed with the MapCHECK and ionization chamber data within the experimental uncertainties (<2% at 1.5 Gy). The system background and minimum detectable dose (MDD) were  <0.5 mGy, and the dose response was approximately linear from the MDD up to a few grays (the linearity correction was  <10% up to ~2-4 Gy), with no saturation up to 30 Gy. The dose profiles agreed with those obtained using EBT3 films (analyzed using the triple channel method) in the high dose regions of the images. In the low dose regions, the dose profiles from the OSLD films were more reproducible than those from the EBT3 films. We also demonstrated that the OSL film data are independent on scan orientation and field size over the investigated range. The results demonstrate the potential of OSLD films for 2D dosimetry, particularly for the characterization of small fields, due to their wide dynamic range, linear response, resolution and dosimetric properties. The negligible background and potential simple calibration make these OSLD films suitable for remote audits. The characterization presented here may motivate further commercial development of a 2D dosimetry system based on the OSL from Al2O3:C or Al2O3:C,Mg.

  18. Landform evolution modeling of fine-grained sedimentation on alluvial fans on Mars and Earth

    NASA Astrophysics Data System (ADS)

    Morgan, A. M.; Howard, A. D.; Moore, J. M.; Swander, Z. J.; Fink, D.; Korup, O.; Hesse, P. P.; Singh, T.; Srivastava, P.

    2017-12-01

    Reconstructing how rivers respond to changes in runoff or sediment supply by incising or aggrading has been pivotal in gauging the role of the Indian Summer Monsoon (ISM) as a geomorphic driver in the Himalayas. Here we present new data on how the fluvial systems of the Lesser Himalaya of India has responded to late Quaternary climate change. Our study is based on new chronological data for fluvial aggradation and incision from the Donga alluvial fan and several reaches of the upper Alaknanda River, as well as a meta-analysis of previous work. Fluvial sediments in the Himalayas in general, and quartz from the region in particular, have been previously noted for a number of unsuitable OSL properties including large recuperation and the existence of unremovable feldspar signals, leading to controversial discussions with regard to the reliability of existing OSL chronologies in this region. In order to improve the applicability and validity of OSL in the Lesser Himalaya, we have tested and applied pulsed OSL signals (POSL) to quartz grains from alluvial terrace and fan sediments, and propose a new chronology of regional fluvial aggradation. For previously dated terraces and alluvial fan sections, our POSL ages are systematically older than previously reported OSL ages. These results suggest periods of aggradation in the Alaknanda and Dehradun Valleys mainly between 20 and 50 ka. This most likely reflects decreased stream power during periods of weakened monsoon. The concentration of in-situ cosmogenic beryllium-10 from fluvial bedrock surfaces was also used to infer bedrock surface exposure ages, which should inform about episodes of active fluvial erosion. Resulting exposure ages span between 1.3 and 9.0 ka, suggesting that strath terraces were exposed relatively recently, and incision was dominant through most of the Holocene. In combination, our results support a precipitation-driven climatic control on fluvial dynamics, which regulates the balance between stream power and sediment supply. On a larger spatial scale, however, fluvial dynamics are probably not homogeneous as aggradation was taking place in adjacent catchments while incision dominated in the study area.

  19. Optically stimulated luminescence of natural NaCl mineral from Dead Sea exposed to gamma radiation.

    PubMed

    Roman-Lopez, J; Piña López, Y I; Cruz-Zaragoza, E; Marcazzó, J

    2018-08-01

    In this work, the continuous wave - optically stimulated luminescence (CW-OSL) emissions of natural salt minerals, collected from Dead Sea in summer of 2015, were studied. The CW-OSL dose response of natural salt showed a linear range between 0.5Gy and 10Gy of gamma radiation of 60 Co. Samples exposed at 3Gy exhibited good repeatability with a variation coefficient of 4.6%. The CW-OSL response as function of the preheating temperature (50-250°C) was analyzed. An increase of 15% of the CW-OSL response was observed in NaCl samples during storage period of 336h. The results showed that the natural Dead Sea salt minerals could be applied as natural dosimeter of gamma radiation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Proceedings of the 4th New World Luminescence Dating and Dosimetry Workshop, Denver, Colorado, May 31 June 2, 2006

    USGS Publications Warehouse

    Wise, Richard A.

    2006-01-01

    Introduction: Optically stimulated luminescence (OSL) is one of a class of measurements known as stimulated phenomena. Such phenomena may be stimulated thermally or optically and the reader is referred to works by Aitken (1998) and Botter-Jensen and others (2003) for more detail. In recent years OSL has become a popular procedure for the determination of environmental radiation doses absorbed by archeological and geological materials in an attempt to date these materials. The first OSL measurements on quartz and feldspar were made using an argon ion-laser (Huntley et al., 1985). However, the development of cheaper stimulation systems based first on filtered lamps and then on light- emitting diodes (LEDs) (Spooner, et al., 1990; Botter-Jensen, and others, 1999) has led to a massive expansion in OSL dating applications. The abstracts in this volume represent presentations from a workshop held in May-June 2006, at the Denver Federal Center, Denver, Colorado, in which OSL methodologies and applications were summarized and integrated to provide a current synthesis of the OSL science being applied throughout North America. The workshop, sponsored by the U.S. Geological Survey Crustal Imaging and Characterization Team and North Dakota State University, was open to all scientists interested in OSL dating techniques and radiation dosimetry. Participants included thirty-six research scientists and students in geology, archaeology, and physics from the U.S. Geological Survey, Los Alamos National Labs, Kentucky Geological Survey, eight universities in the United States, one university in Canada, one university in India, and Riso National Labs of Denmark. The workshop included two keynote speakers: Dr. Ashok Singhvi (Physical Research Laboratory, Ahmedabad, India) spoke on 'Some Unexplored Methodological Aspects and Some New Applications of Luminescence Dating,' while Dr. Jim Feathers (University of Seattle, WA) spoke on OSL Dating of Sediments From Paleoindian Sites in Brazil. The workshop encouraged everyone to interact more to develop a broader perspective on the types of research and the problems encountered when reporting OSL ages. This meeting follows the first North American Luminescence Dating Workshop held in Tulsa, OK, by Oklahoma State University (2001), in Albuquerque, NM, by Los Alamos National Labs (2002), and in Halifax, Nova Scotia, by Dalhousie University (2004, with a name change to New World Luminescence Dating Workshop). These workshops were interspersed with the international meetings on luminescence that were held in Reno, NV, (2002), and Cologne, Germany; (2005).

  1. Synthesis and TL/OSL properties of a novel high-sensitive blue-emitting LiSrPO4:Eu2+ phosphor for radiation dosimetry

    NASA Astrophysics Data System (ADS)

    Palan, C. B.; Koparkar, K. A.; Bajaj, N. S.; Soni, A.; Omanwar, S. K.

    2016-07-01

    In this study, a series of Eu2+-doped LiSrPO4 phosphors were synthesized via solid-state method. The structural and morphological characterizations were done through X-ray diffraction and scanning electronic microscope. Additionally, the photoluminescence (PL), thermoluminescence (TL) and optically stimulated luminescence (OSL) behaviours of LiSrPO4:Eu2+ phosphors were studied. The LiSrPO4:Eu2+ phosphor shows OSL sensitivity about 8 times than that of α-Al2O3:C phosphor and 6 times than that of LiMgPO4:Tb3+, B phosphor. Moreover, TL sensitivity was about 15 times more as compared to α-Al2O3:C phosphor. The kinetic parameters of TL curve were calculated using peak shape method. In TL/OSL mode, dose-response was almost linear nature, in the range of measurement. The minimum detectable dose was found to be 25.18 μGy with 3 σ of background. Also, reusability was also studies, which shows the phosphor can be reusable for 10 cycles with 0.1 % change in OSL output.

  2. Long persistent and optically stimulated luminescence behaviors of calcium aluminates with different trap filling processes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Buhao; Xu, Xuhui; Li, Qianyue

    Properties of long persistent luminescence (LPL) and optically stimulated luminescence (OSL) of CaAl{sub 2}O{sub 4}:Eu{sup 2+}, R{sup 3+} (R=Nd, Dy, Tm) materials were investigated. The observed phenomenon indicates that R{sup 3+} ions (R=Nd, Dy, Tm) have different effects on trap properties of CaAl{sub 2}O{sub 4}:Eu{sup 2+}. The greatly improved LPL performance was observed in Nd{sup 3+} co-doped samples, which indicates that the incorporation of Nd{sup 3+} creates suitable traps for LPL. While co-doping Tm{sup 3+} ions, the intensity of high temperature of thermoluminescence band in CaAl{sub 2}O{sub 4}:Eu{sup 2+} phosphors is enhanced for the formation of the most suitable trapsmore » which benefits the intense and stable OSL. These results suggest that the effective traps contributed to the LPL/OSL are complex, of which could be an aggregation formation with shallow and deep traps other than simple traps from co-doped R{sup 3+} ions. The mechanism presented in the end potentially provides explanations of why the OSL of CaAl{sub 2}O{sub 4}:Eu{sup 2+}, R{sup 3+} exhibits different read-in/read-out performance as well. - Graphical abstract: OSL emission spectra of Ca{sub 0.995}Al{sub 2}O{sub 4}:0.0025Eu{sup 2+}, 0.0025R{sup 3+} (R=Nd, Dy, Tm) taken under varying stimulation time (0, 25, 50, 75, 100 s). Inset: Blue emission pictures under varying stimulation time. - Highlights: • The LPL and OSL properties of CaAl{sub 2}O{sub 4}:Eu{sup 2+}, R{sup 3+} were investigated. • An alternative approach to control the trap depth of CaAl{sub 2}O{sub 4}:Eu{sup 2+} phosphor was proposed. • A new oxide ETM phosphor exhibiting intense and stable OSL was explored.« less

  3. A laser based frequency modulated NL-OSL phenomenon

    NASA Astrophysics Data System (ADS)

    Mishra, D. R.; Bishnoi, A. S.; Soni, Anuj; Rawat, N. S.; Bhatt, B. C.; Kulkarni, M. S.; Babu, D. A. R.

    2015-01-01

    The detailed theoretical and experimental approach to novel technique of pulse frequency modulated stimulation (PFMS) method has been described for NL-OSL phenomenon. This method involved pulsed frequency modulation with respect to time for fixed pulse width of 532 nm continuous wave (CW)-laser light. The linearly modulated (LM)-, non-linearly (NL)-stimulation profiles have been generated using fast electromagnetic optical shutter. The PFMS parameters have been determined for present experimental setup. The PFMS based LM-, NL-OSL studies have been carried out on dosimetry grade single crystal α-Al2O3:C. The photo ionization cross section of α-Al2O3:C has been found to be ∼9.97 × 10-19 cm2 for 532 nm laser light using PFMS LM-OSL studies under assumption of first order of kinetic. This method of PFMS is found to be a potential alternative to generate different stimulation profiles using CW-light sources.

  4. Development of OSL system using two high-density blue LEDs equipped with liquid light guides

    NASA Astrophysics Data System (ADS)

    Choi, J. H.; Kim, M. J.; Cheong, C. S.; Hong, D. G.

    2014-03-01

    In recent years, considerable developments in optically stimulated luminescence (OSL) have been made in the fields of radiation dosimetry, age determination, and medical applications. A compact and economical OSL system comprising a precision x-y-z stage for loading 12 samples, a small X-ray generator for radiation dosing, and two powerful blue light emitting diodes (LEDs) for optical stimulation equipped with VIS liquid light guides (VIS-LLGs) has been developed. This paper describes the principal features of the system along with the examples of measurements performed by the system.

  5. Characterization of OSL dosimeters for use in dose assessment in Computed Tomography procedures.

    PubMed

    Giansante, Louise; Santos, Josilene C; Umisedo, Nancy K; Terini, Ricardo A; Costa, Paulo R

    2018-03-01

    This study describes the characterization of an Al 2 O 3 :C OSLD (Landauer's Luxel™ tape) for dose evaluation in Computed Tomography. The irradiations were conducted using both a constant potential X-ray equipment and a 64-slice clinical CT scanner, and the readouts were performed using a Risø TL/OSL reader. The following aspects were studied: batch homogeneity, energy response, linearity of dose response, reproducibility, reusability, and effect of uncertainties with the normalization of OSL signals per their response to beta radiation. A group of 330 dosimeters from the 452 irradiated with the same dose presented OSL signals within the interval of 4.7% from the average. The dosimeters presented energy-dependent response in good agreement with results found in the literature. The air kerma response of the OSL signal showed a linear trend for both the constant potential X-ray device and the clinical CT scanner, with differences in their slopes of approximately 10%. Reproducibility, reusability, and effect of beta normalization were analyzed by separating 72 dosimeters in 3 groups. The results obtained in this study together with those of previous works indicate that this type of dosimeter is adequate for dose evaluation in CT clinical applications. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  6. Optically Stimulated Luminescence (OSL) of Tooth Enamel and its Potential Use in Post-Radiation Exposure Triage

    PubMed Central

    DeWitt, R.; Klein, D. M.; Yukihara, E. G.; Simon, S. L.; McKeever, S. W. S.

    2009-01-01

    Optically stimulated luminescence (OSL) properties of dental enamel are discussed with a view to the development of an in-vivo dose assessment technique for medical triage following a radiological/nuclear accident or terrorist event. In the OSL technique, past radiation exposure is assessed by stimulating the sample with light of one wavelength and monitoring the luminescence at another wavelength under the assumption that the luminescence originates from the recombination of radiation-induced charges trapped at metastable defects in the enamel and that the intensity of the luminescence signal is in proportion to the absorbed radiation dose. Several primary findings emerged from this research: (a) sensitivities varied considerably between different teeth and also between fragments of the same tooth, (b) OSL signals were found to decay rapidly during the first 12 hours after irradiation and slower afterwards, (c) the fading rate of the luminescence signal varied between fragments, (d) blue light stimulation yields greater sensitivity than infra-red stimulation, while the OSL signal obtained with a high-intensity pulsed green-light laser was found to be not correlated with the radiation dose. Significant challenges remain to developing a practical in-vivo technique including the development of calibration procedures and lowering minimum detectable doses. PMID:20065717

  7. Optically stimulated luminescence (OSL) of carbon-doped aluminum oxide (Al{sub 2}O{sub 3}:C) for film dosimetry in radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schembri, V.; Heijmen, B. J. M.

    2007-06-15

    Introduction and Purpose: Conventional x-ray films and radiochromic films have inherent challenges for high precision radiotherapy dosimetry. Here we have investigated basic characteristics of optically stimulated luminescence (OSL) of irradiated films containing carbon-doped aluminum oxide (Al{sub 2}O{sub 3}:C) for dosimetry in therapeutic photon and electron beams. Materials and Methods: The OSL films consist of a polystyrene sheet, with a top layer of a mixture of single crystals of Al{sub 2}O{sub 3}:C, ground into a powder, and a polyester base. The total thickness of the films is 0.3 mm. Measurements have been performed in a water equivalent phantom, using 4, 6,more » 10, and 18 MV photon beams, and 6-22 MeV electron beams. The studies include assessment of the film response (acquired OSL signal/delivered dose) on delivered dose (linearity), dose rate (1-6 Gy/min), beam quality, field size and depth (6 MV, ranges 4x4-30x30 cm{sup 2}, d{sub max}-35 cm). Doses have been derived from ionization chamber measurements. OSL films have also been compared with conventional x-ray and GafChromic films for dosimetry outside the high dose area, with a high proportion of low dose scattered photons. In total, 787 OSL films have been irradiated. Results: Overall, the OSL response for electron beams was 3.6% lower than for photon beams. Differences between the various electron beam energies were not significant. The 6 and 18 MV photon beams differed in response by 4%. No response dependencies on dose rate were observed. For the 6 MV beam, the field size and depth dependencies of the OSL response were within {+-}2.5%. The observed inter-film response variation for films irradiated with the same dose varied from 1% to 3.2% (1 SD), depending on the measurement day. At a depth of 20 cm, 5 cm outside the 20x20 cm{sup 2} 6 and 18 MV beams, an over response of 17% was observed. In contrast to GafChromic and conventional x-ray films, the response of the Al{sub 2}O{sub 3}:C films is linear in the clinically relevant dose range 0-200 cGy. Conclusions: Measurement of the OSL signal of irradiated films containing Al{sub 2}O{sub 3}:C is a promising technique for film dosimetry in radiotherapy with no or small response variations with dose rate, beam quality, field size and depth, and a linear response from 0 to 200 cGy.« less

  8. Characteristics of an OSLD in the diagnostic energy range.

    PubMed

    Al-Senan, Rani M; Hatab, Mustapha R

    2011-07-01

    Optically stimulated luminescence (OSL) dosimetry has been recently introduced in radiation therapy as a potential alternative to the thermoluminescent dosimeter (TLD) system. The aim of this study was to investigate the feasibility of using OSL point dosimeters in the energy range used in diagnostic imaging. NanoDot OSL dosimeters (OSLDs) were used in this study, which started with testing the homogeneity of a new packet of nanoDots. Reproducibility and the effect of optical treatment (bleaching) were then examined, followed by an investigation of the effect of accumulated dose on the OSLD indicated doses. OSLD linearity, angular dependence, and energy dependence were also studied. Furthermore, comparison with LiF:Mg,Ti TLD chips using standard CT dose phantoms at 80 and 120 kVp settings was performed. Batch homogeneity showed a coefficient of variation of <5%. Single-irradiation measurements with bleaching after each OSL readout was found to be associated with a 3.3% reproducibility (one standard deviation measured with a 8 mGy test dose), and no systematic change in OSLDs sensitivity could be noted from measurement to measurement. In contrast, the multiple-irradiation readout without bleaching in between measurements was found to be associated with an uncertainty (using a 6 mGy test dose) that systematically increased with accumulated dose, reaching 42% at 82 mGy. Good linearity was shown by nanoDots under general x-ray, CT, and mammography units with an R2 > 0.99. The angular dependence test showed a drop of approximately 70% in the OSLD response at 90 degrees in mammography (25 kVp). With the general radiography unit, the maximum drop was 40% at 80 kVp and 20% at 120 kVp, and it was only 10% with CT at both 80 and 120 kVp. The energy dependence study showed a range of ion chamber-to-OSLDs ratios between 0.81 and 1.56, at the energies investigated (29-62 keV). A paired t-test for comparing the OSLDs and TLDs showed no significant variation (p > 0.1). OSLDs exhibited good batch homogeneity (<5%) and reproducibility (3.3%), as well as a linear response. In addition, they showed no statistically significant difference with TLDs in CT measurements (p > 0.1). However, high uncertainty (42%) in the dose estimate was found as a result of relatively high accumulated dose. Furthermore, nanoDots showed high angular dependence (up to 70%) in low kVp techniques. Energy dependence of about 60% was found, and correction factors were suggested for the range of energies investigated. Therefore, if angular and energy dependences are taken into consideration and the uncertainty associated with accumulated dose is avoided, OSLDs (nanoDots) can be suitable for use as point dosimeters in diagnostic settings.

  9. Estimation of identification limit for a small-type OSL dosimeter on the medical images by measurement of X-ray spectra.

    PubMed

    Takegami, Kazuki; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi; Maehata, Itsumi; Kanazawa, Yuki; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo

    2016-07-01

    Our aim in this study is to derive an identification limit on a dosimeter for not disturbing a medical image when patients wear a small-type optically stimulated luminescence (OSL) dosimeter on their bodies during X-ray diagnostic imaging. For evaluation of the detection limit based on an analysis of X-ray spectra, we propose a new quantitative identification method. We performed experiments for which we used diagnostic X-ray equipment, a soft-tissue-equivalent phantom (1-20 cm), and a CdTe X-ray spectrometer assuming one pixel of the X-ray imaging detector. Then, with the following two experimental settings, corresponding X-ray spectra were measured with 40-120 kVp and 0.5-1000 mAs at a source-to-detector distance of 100 cm: (1) X-rays penetrating a soft-tissue-equivalent phantom with the OSL dosimeter attached directly on the phantom, and (2) X-rays penetrating only the soft-tissue-equivalent phantom. Next, the energy fluence and errors in the fluence were calculated from the spectra. When the energy fluence with errors concerning these two experimental conditions was estimated to be indistinctive, we defined the condition as the OSL dosimeter not being identified on the X-ray image. Based on our analysis, we determined the identification limit of the dosimeter. We then compared our results with those for the general irradiation conditions used in clinics. We found that the OSL dosimeter could not be identified under the irradiation conditions of abdominal and chest radiography, namely, one can apply the OSL dosimeter to measurement of the exposure dose in the irradiation field of X-rays without disturbing medical images.

  10. Tests and foreseen developments of fibered-OSLD gamma heating measurements in low-power reactors

    NASA Astrophysics Data System (ADS)

    Gruel, A.; Guillou, M. Le; Blaise, P.; Destouches, C.; Magne, S.

    2018-01-01

    In this paper are presented test measurements of a fibered-OSLD system performed during a dedicated experimental phase in EOLE zero-power reactor. The measurement setup consists of an OSLD crystal connected onto the extremity of an optical fiber and a laser stimulation system, manufactured by the CEA/LIST in Saclay. The OSL sensor is remotely stimulated via an optical fiber using a diode-pumped solid-state laser. The OSL light is collected and guided back along the same fiber to a photomultiplier tube. Results obtained using this system are compared to usual gamma heating measurement protocol using OSLD pellets. The presence of induced radio-luminescence in the OSLD during the irradiation was also observed and could be used to monitor the gamma flux. The feasibility of remote measurements is achieved, whereas further developments could be conducted to improve this technique since the readout procedure still requires to withdraw the OSLD off the gamma flux (hence from the core) on account of the dose rate (around a few Gy.h-1), and the readout time remains quite long for on-line applications. Several improvements are foreseen, and will be tested in the forthcoming years.

  11. TL and OSL characterization of Eu3+ doped Y2O3: Application in dosimetry

    NASA Astrophysics Data System (ADS)

    Shivaramu, N. J.; Coetsee, E.; Swart, H. C.

    2018-05-01

    Thermoluminescence (TL) and optically stimulated luminescence (OSL) properties of beta irradiated Eu3+ doped Y2O3 nanophosphor have been investigated in this paper. The Eu3+ doped Y2O3 nanophosphor was synthesized by solution combustion technique and synthesized material was annealed at 900°C. The annealed materials were exposed to β-ray for various dose. TL glow with prominent peak at 403 K and weak glow peak at 660 K were observed in all irradiated samples. It is found that TL glow peaks intensity linearly increases with increase in β-dose from 8.125 - 40.625 Gy. The TL kinetic parameters were calculated using glow curve deconvoluted (GCD) and peak shape methods. The TL glows exhibits general order kinetics. Intense continuous wave optical stimulated luminescence (CW-OSL) was observed in the sample. These material exhibits linearity at low dose, good reproducibility and response of intense OSL and hence, these results suggests that this material may be suitable for dosimetry applications.

  12. Single photon detection and signal analysis for high sensitivity dosimetry based on optically stimulated luminescence with beryllium oxide

    NASA Astrophysics Data System (ADS)

    Radtke, J.; Sponner, J.; Jakobi, C.; Schneider, J.; Sommer, M.; Teichmann, T.; Ullrich, W.; Henniger, J.; Kormoll, T.

    2018-01-01

    Single photon detection applied to optically stimulated luminescence (OSL) dosimetry is a promising approach due to the low level of luminescence light and the known statistical behavior of single photon events. Time resolved detection allows to apply a variety of different and independent data analysis methods. Furthermore, using amplitude modulated stimulation impresses time- and frequency information into the OSL light and therefore allows for additional means of analysis. Considering the impressed frequency information, data analysis by using Fourier transform algorithms or other digital filters can be used for separating the OSL signal from unwanted light or events generated by other phenomena. This potentially lowers the detection limits of low dose measurements and might improve the reproducibility and stability of obtained data. In this work, an OSL system based on a single photon detector, a fast and accurate stimulation unit and an FPGA is presented. Different analysis algorithms which are applied to the single photon data are discussed.

  13. Investing the temporal and spatial scale variations of luminescence sensitivity of loess in the Chinese Loess Plateau since the last interglacial

    NASA Astrophysics Data System (ADS)

    Lv, T.; Sun, J.; Gong, Z.

    2017-12-01

    The provenance of the eolian deposits on the Loess Plateau has long been one of the most important issues. Although the luminescence sensitivity of the quartz grains of desert sands has been used in tracing provenance, and the vertical variation of OSL sensitivity of Loess in the central Chinese Loess plateau (CLP) has been studied, it still remains uncertain about the temporal and spatial scale variations of luminescence sensitivity of loess. This paper chose the eolian deposits of Shimao (SM) section in the northern margin of the Chinese Loess Plateau and of Luochuan (LC) section in the central Chinese Loess Plateau. Firstly, the temporal scale variations of luminescence sensitivity of different quartz grians (38-64 and 64-90μm) from sand/loess of SM section have been studied respectively. Our results indicate that they both have similar trend in the strength of luminescence sensitivity, characterized by lower values in sand/loess beds and higher values in soils. The OSL sensitivity of quartz grains of the sand-loess-soil sequence shows very similar trend to the magnetic susceptibility fluctuations. Secondly, the spatial scale variations of luminescence sensitivity of loess in the Chinese Loess Plateau since the last interglacial were studied by comparing the values of SM section and LC section. The OSL sensitivity of quartz grains from the two sections since the last interglacial change synchronously. However, the OSL sensitivity values of quartz grains from the same loess/paleosol beds of LC section are higher than these values of SM section. We suggest that the temporal variation of OSL sensitivity of SM is main influenced by the retreat-advance of deserts. The spatial variation of OSL sensitivity mainly is due to the different sedimentary history, containing of repeated erosion, transport and deposition cycles which controlled by cyclic climatic change. The higher OSL sensitivity values of quartz grains in LC section relates of longer transport distance and of more sedimentary history than these values in SM section. Keywords: Luminescence sensitivity; Quartz; provenance; Loess Plateau

  14. Optimizing a readout protocol for low dose retrospective OSL-dosimetry using household salt.

    PubMed

    Christiansson, Maria; Mattsson, Sören; Bernhardsson, Christian; Rääf, Christopher L

    2012-06-01

    The authors' aim has been to find a single aliquot regenerative dose (SAR) protocol that accurately recovers an unknown absorbed dose in the region between 1-250 mGy in household salt. The main investigation has been conducted on a specific mine salt (>98.5% NaCl) intended for household use, using optical stimulation by blue LED (λ = 462 nm). The most accurate dose recovery for this brand of salt is found to be achieved when using Peak Signal Summing (PSS) of the OSL-decay and a preheat temperature of 200°C after the test dose. A SAR protocol for the household salt with preset values of regenerative doses (R1--R5) and a test dose (TED) of 17 mGy is also suggested here. Under laboratory conditions, the suggested protocol recovers unknown absorbed doses in this particular brand within 5% (2 SD) in the dose range between 1-250 mGy. This is a very promising result for low dose applications of household salt as a retrospective dosimeter after a nuclear or radiological event.

  15. An application of artificial neural intelligence for personal dose assessment using a multi-area OSL dosimetry system.

    PubMed

    Lee, S Y; Kim, B H; Lee, K J

    2001-06-01

    Significant advances have been made in recent years to improve measurement technology and performance of phosphor materials in the fields of optically stimulated luminescence (OSL) dosimetry. Pulsed and continuous wave OSL studies recently carried out on alpha-Al2O3:C have shown that the material seems to be the most promising for routine application of OSL for dosimetric purposes. The main objective of the study is to propose a new personal dosimetry system using alpha-Al2O3:C by taking advantage of its optical properties and energy dependencies. In the process of the study, a new dose assessment algorithm was developed using artificial neural networks in hopes of achieving a higher degree of accuracy and precision in personal OSL dosimetry system. The original hypothesis of this work is that the spectral information of X- and gamma-ray fields may be obtained by the analysis of the response of a multi-element system. In this study, a feedforward neural network using the error back-propagation method with Bayesian optimization was applied for the response unfolding procedure. The validation of the proposed algorithm was investigated by unfolding the 10 measured responses of alpha-Al2O3:C for arbitrarily mixed photon fields which range from 20 to 662 keV. c2001 Elsevier Science Ltd. All rights reserved.

  16. High-precision dosimetry for radiotherapy using the optically stimulated luminescence technique and thin Al2O3:C dosimeters.

    PubMed

    Yukihara, E G; Yoshimura, E M; Lindstrom, T D; Ahmad, S; Taylor, K K; Mardirossian, G

    2005-12-07

    The potential of using the optically stimulated luminescence (OSL) technique with aluminium oxide (Al(2)O(3):C) dosimeters for a precise and accurate estimation of absorbed doses delivered by high-energy photon beams was investigated. This study demonstrates the high reproducibility of the OSL measurements and presents a preliminary determination of the depth-dose curve in water for a 6 MV photon beam from a linear accelerator. The uncertainty of a single OSL measurement, estimated from the variance of a large sample of dosimeters irradiated with the same dose, was 0.7%. In the depth-dose curve obtained using the OSL technique, the difference between the measured and expected doses was < or =0.7% for depths between 1.5 and 10 cm, and 1.1% for a depth of 15 cm. The readout procedure includes a normalization of the response of the dosimeter with respect to a reference dose in order to eliminate variations in the dosimeter mass, dosimeter sensitivity, and the reader's sensitivity. This may be relevant for quality assurance programmes, since it simplifies the requirements in terms of personnel training to achieve the precision and accuracy necessary for radiotherapy applications. We concluded that the OSL technique has the potential to be reliably incorporated in quality assurance programmes and dose verification.

  17. Optically stimulated luminescence and thermoluminescence efficiencies for high-energy heavy charged particle irradiation in Al2O3:C.

    PubMed

    Yukihara, E G; Gaza, R; McKeever, S W S; Soares, C G

    2004-02-01

    The thermally and optically stimulated luminescence (TL and OSL) response to high energy heavy-charged particles (HCPs) was investigated for two types of Al2O3:C luminescence dosimeters. The OSL signal was measured in both continuous-wave (CW) and pulsed mode. The efficiencies of the HCPs at producing TL or OSL, relative to gamma radiation, were obtained using four different HCPs beams (150 MeV/u 4He, 400 MeV/u 12C, 490 MeV/u 28Si, and 500 MeV/u 56Fe). The efficiencies were determined as a function of the HCP linear energy transfer (LET). It was observed that the efficiency depends on the type of detector, measurement technique, and the choice of signal. Additionally, it is shown that the shape of the CW-OSL decay curve from Al2O3:C depends on the type of radiation, and, in principle, this can be used to extract information concerning the LET of an unknown radiation field. The response of the dosimeters to low-LET radiation was also investigated for doses in the range from about 1-1000 Gy. These data were used to explain the different efficiency values obtained for the different materials and techniques, as well as the LET dependence of the CW-OSL decay curve shape. c2003 Elsevier Ltd. All rights reserved.

  18. Optically stimulated luminescence and thermoluminescence efficiencies for high-energy heavy charged particle irradiation in Al2O3:C

    NASA Technical Reports Server (NTRS)

    Yukihara, E. G.; Gaza, R.; McKeever, S. W. S.; Soares, C. G.

    2004-01-01

    The thermally and optically stimulated luminescence (TL and OSL) response to high energy heavy-charged particles (HCPs) was investigated for two types of Al2O3:C luminescence dosimeters. The OSL signal was measured in both continuous-wave (CW) and pulsed mode. The efficiencies of the HCPs at producing TL or OSL, relative to gamma radiation, were obtained using four different HCPs beams (150 MeV/u 4He, 400 MeV/u 12C, 490 MeV/u 28Si, and 500 MeV/u 56Fe). The efficiencies were determined as a function of the HCP linear energy transfer (LET). It was observed that the efficiency depends on the type of detector, measurement technique, and the choice of signal. Additionally, it is shown that the shape of the CW-OSL decay curve from Al2O3:C depends on the type of radiation, and, in principle, this can be used to extract information concerning the LET of an unknown radiation field. The response of the dosimeters to low-LET radiation was also investigated for doses in the range from about 1-1000 Gy. These data were used to explain the different efficiency values obtained for the different materials and techniques, as well as the LET dependence of the CW-OSL decay curve shape. c2003 Elsevier Ltd. All rights reserved.

  19. Collective odor source estimation and search in time-variant airflow environments using mobile robots.

    PubMed

    Meng, Qing-Hao; Yang, Wei-Xing; Wang, Yang; Zeng, Ming

    2011-01-01

    This paper addresses the collective odor source localization (OSL) problem in a time-varying airflow environment using mobile robots. A novel OSL methodology which combines odor-source probability estimation and multiple robots' search is proposed. The estimation phase consists of two steps: firstly, the separate probability-distribution map of odor source is estimated via Bayesian rules and fuzzy inference based on a single robot's detection events; secondly, the separate maps estimated by different robots at different times are fused into a combined map by way of distance based superposition. The multi-robot search behaviors are coordinated via a particle swarm optimization algorithm, where the estimated odor-source probability distribution is used to express the fitness functions. In the process of OSL, the estimation phase provides the prior knowledge for the searching while the searching verifies the estimation results, and both phases are implemented iteratively. The results of simulations for large-scale advection-diffusion plume environments and experiments using real robots in an indoor airflow environment validate the feasibility and robustness of the proposed OSL method.

  20. Collective Odor Source Estimation and Search in Time-Variant Airflow Environments Using Mobile Robots

    PubMed Central

    Meng, Qing-Hao; Yang, Wei-Xing; Wang, Yang; Zeng, Ming

    2011-01-01

    This paper addresses the collective odor source localization (OSL) problem in a time-varying airflow environment using mobile robots. A novel OSL methodology which combines odor-source probability estimation and multiple robots’ search is proposed. The estimation phase consists of two steps: firstly, the separate probability-distribution map of odor source is estimated via Bayesian rules and fuzzy inference based on a single robot’s detection events; secondly, the separate maps estimated by different robots at different times are fused into a combined map by way of distance based superposition. The multi-robot search behaviors are coordinated via a particle swarm optimization algorithm, where the estimated odor-source probability distribution is used to express the fitness functions. In the process of OSL, the estimation phase provides the prior knowledge for the searching while the searching verifies the estimation results, and both phases are implemented iteratively. The results of simulations for large-scale advection–diffusion plume environments and experiments using real robots in an indoor airflow environment validate the feasibility and robustness of the proposed OSL method. PMID:22346650

  1. Late Quaternary stratigraphy and luminescence geochronology of the northeastern Mojave Desert

    USGS Publications Warehouse

    Mahan, S.A.; Miller, D.M.; Menges, C.M.; Yount, J.C.

    2007-01-01

    The chronology of the Holocene and late Pleistocene deposits of the northeastern Mojave Desert have been largely obtained using radiocarbon ages. Our study refines and extends this framework using optically stimulated luminescence (OSL) to date deposits from Valjean Valley, Silurian Lake Playa, Red Pass, and California Valley. Of particular interest are eolian fine silts incorporated in ground-water discharge (GWD) deposits bracketed at 185-140 and 20-50 ka. Alluvial fan deposits proved amenable for OSL by dating both eolian sand lenses and reworked eolian sand in a matrix of gravel that occurs within the fan stratigraphy. Lacustrine sand in spits and bars also yielded acceptable OSL ages. These OSL ages fill gaps in the geochronology of desert deposits, which can provide data relevant to understanding the responses of several depositional systems to regional changes in climate. This study identifies the most promising deposits for future luminescence dating and suggests that for several regions of the Mojave Desert, sediments from previously undated landforms can be more accurately placed within correct geologic map units.

  2. Development of a personal dosimetry system based on optically stimulated luminescence of alpha-Al2O3:C for mixed radiation fields.

    PubMed

    Lee, S Y; Lee, K J

    2001-04-01

    To develop a personal optically stimulated luminescence (OSL) dosimetry system for mixed radiation fields using alpha-Al2O3:C, a discriminating badge filter system was designed by taking advantage of its optically stimulable properties and energy dependencies. This was done by designing a multi-element badge system for powder layered alpha-Al2O3:C material and an optical reader system based on high-intensity blue light-emitting diode (LED). The design of the multielement OSL dosimeter badge system developed allows the measurement of a personal dose equivalent value Hp(d) in mixed radiation fields of beta and gamma. Dosimetric properties of the personal OSL dosimeter badge system investigated here were the dose response, energy response and multi-readability. Based on the computational simulations and experiments of the proposed dosimeter design, it was demonstrated that a multi-element dosimeter system with an OSL technology based on alpha-Al2O3:C is suitable to obtain personal dose equivalent information in mixed radiation fields.

  3. Late Cenozoic Deformation in the Western Tarim Basin, NW China

    NASA Astrophysics Data System (ADS)

    Thompson, J. A.; Burbank, D. W.; Chen, J.; Li, T.

    2009-12-01

    The Tian Shan in NW China is one of the most active regions of intracontinental deformation in the world, accommodating a large fraction (~40%) of the shortening from the Indo-Eurasian collision. The western Tarim Basin, situated between the southern Tian Shan and Pamir Mountains, manifests this deformation through a series of east-west trending fault-related folds that have formed during the late Cenozoic. Previous studies in this region have focused on the kinematics, style, and timing of detachment folds related to folding within the foreland basin of the southern Tian Shan. In contrast, this study focuses on the deformation caused by fault-propagation folding resulting from the northward movement of the Pamir. The rates of deformation are calculated using a combination of optically stimulated luminescence (OSL) ages, structural mapping and differential GPS surveys of fault scarps and deformed terrace surfaces crossing active folds. OSL dating provides the time since the sediment was last exposed to daylight, i.e., time since burial. Consequently, OSL is useful for dating the abandonment of terrace surfaces due to tectonic (fold growth) or climatic events. OSL quartz samples were collected from silt lenses within gravel topping the terraces. Most of the quartz OSL signals are weak, thus several grain sizes (silt (4-11 µm, 8-15 µm) and sand (90-125 µm)) were analyzed and different integrations of the shine-down curves were explored to calculate equivalent doses. The implications for different equivalent doses and ages on the calculation of rates of deformation are also addressed.

  4. Temperature-dependent OSL properties of nano-phosphors LiAlO2:C and α-Al2O3:C

    NASA Astrophysics Data System (ADS)

    Agarwal, Mini; Garg, Sandeep K.; Asokan, K.; Kumar, Pratik

    2018-06-01

    The present study focuses on the synthesis and characterization of carbon doped nano-phosphors, LiAlO2 and α-Al2O3 and their temperature-dependent optically stimulated luminescence (TA-OSL) characteristics in the temperature ranges of 25-350 °C. These nano-phosphors with the carbon concentration of 0.01 mol% exhibits high luminescent intensity for LiAlO2:C in the low dose range of 1 mGy-7 Gy and for α-Al2O3:C in the range of 100 mGy-1 kGy. Both these nano-phosphors are of polycrystalline in nature, having grain size 15-50 nm as confirmed by the X-ray diffraction (XRD) and Transmission Electron Microscopy (TEM), respectively. The maximum TA-OSL intensities are observed at 125 °C for LiAlO2:C and 200 °C for Al2O3:C, and reveal the presence of deep defect centres. The Arrhenius analysis shows the activation energies Ea = 0.06 ± 0.02 eV for LiAlO2:C and Ea = 0.04 ± 0.01 eV, & Eb = 0.48 ± 0.07 eV for Al2O3:C. The TA-OSL and OSL characteristics are discussed with special reference to the medical and high radiation dosimetry. These compounds, LiAlO2:C and α-Al2O3:C, are non-toxic, robust and are potential candidates for reusable dosimetry.

  5. Characteristics of an OSLD in the diagnostic energy range

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Al-Senan, Rani M.; Hatab, Mustapha R.

    2011-07-15

    Purpose: Optically stimulated luminescence (OSL) dosimetry has been recently introduced in radiation therapy as a potential alternative to the thermoluminescent dosimeter (TLD) system. The aim of this study was to investigate the feasibility of using OSL point dosimeters in the energy range used in diagnostic imaging. Methods: NanoDot OSL dosimeters (OSLDs) were used in this study, which started with testing the homogeneity of a new packet of nanoDots. Reproducibility and the effect of optical treatment (bleaching) were then examined, followed by an investigation of the effect of accumulated dose on the OSLD indicated doses. OSLD linearity, angular dependence, and energymore » dependence were also studied. Furthermore, comparison with LiF:Mg,Ti TLD chips using standard CT dose phantoms at 80 and 120 kVp settings was performed. Results: Batch homogeneity showed a coefficient of variation of <5%. Single-irradiation measurements with bleaching after each OSL readout was found to be associated with a 3.3% reproducibility (one standard deviation measured with a 8 mGy test dose), and no systematic change in OSLDs sensitivity could be noted from measurement to measurement. In contrast, the multiple-irradiation readout without bleaching in between measurements was found to be associated with an uncertainty (using a 6 mGy test dose) that systematically increased with accumulated dose, reaching 42% at 82 mGy. Good linearity was shown by nanoDots under general x-ray, CT, and mammography units with an R{sup 2} > 0.99. The angular dependence test showed a drop of approximately 70% in the OSLD response at 90 deg. in mammography (25 kVp). With the general radiography unit, the maximum drop was 40% at 80 kVp and 20% at 120 kVp, and it was only 10% with CT at both 80 and 120 kVp. The energy dependence study showed a range of ion chamber-to-OSLDs ratios between 0.81 and 1.56, at the energies investigated (29-62 keV). A paired t-test for comparing the OSLDs and TLDs showed no significant variation (p > 0.1). Conclusions: OSLDs exhibited good batch homogeneity (<5%) and reproducibility (3.3%), as well as a linear response. In addition, they showed no statistically significant difference with TLDs in CT measurements (p > 0.1). However, high uncertainty (42%) in the dose estimate was found as a result of relatively high accumulated dose. Furthermore, nanoDots showed high angular dependence (up to 70%) in low kVp techniques. Energy dependence of about 60% was found, and correction factors were suggested for the range of energies investigated. Therefore, if angular and energy dependences are taken into consideration and the uncertainty associated with accumulated dose is avoided, OSLDs (nanoDots) can be suitable for use as point dosimeters in diagnostic settings.« less

  6. OSL surface exposure dating of wave-emplaced coastal boulders - Research concept and first results from the Rabat coast, Morocco

    NASA Astrophysics Data System (ADS)

    Brill, Dominik; May, Simon Matthias; Mhammdi, Nadia; King, Georgina; Brückner, Helmut

    2017-04-01

    Fields of wave-emplaced blocks and boulders represent impressive evidence of cyclone and tsunami flooding over Holocene time scales. Unfortunately, their use for coastal hazard assessment is in many cases impeded by the absence of appropriate dating approaches, which are needed to generate robust chronologies. The commonly applied AMS-14C, U/Th or ESR dating of coral-reef rocks and marine organisms attached to the clasts depends on a - mostly hypothetical - coincidence between the organisms' death and boulder displacement, and inferred event chronologies may be biased by the marine 14C-reservoir effect and reworked organisms. Here we discuss the potential of the recently developed optically stimulated luminescence (OSL) surface exposure dating technique to directly date the relocation process of wave-emplaced boulders. By measuring the depth-dependent resetting of luminescence signals in exposed rock surfaces and comparing it to the signal-depth profiles of known-age samples, OSL surface exposure dating may be capable to model direct depositional ages for boulder transport. Thereby, it promises to overcome the limitations of existing dating techniques, and to decipher complex transport histories of clasts that underwent multiple phases of exposure and burial. The concept and some first results of OSL surface exposure dating shall be presented for coastal boulders from the Rabat coast, Morocco, where the preconditions for successful dating are promising: (i) Several coastal boulders show clear indication of overturning during wave transport in the form of downward-facing bio-eroded surfaces; (ii) the boulders are composed of different types of sandstone that contain quartz and feldspar, the required dosimeters for OSL dating; (iii) all boulders are of Holocene age and, therefore, in the dating range of OSL surface exposure dating. The main challenges for a successful application are the intensive bio-erosion and weathering of some surfaces exposed after transport, and the need for method calibration using surfaces with similar lithology and known exposure ages. However, in the best case, OSL surface exposure dating will provide quantitative information about the frequency-magnitude relationship of extreme wave events at the Rabat coast, in particular determining whether severe tsunami-induced flooding can be expected (e.g. during the 1755 Lisbon tsunami and similar events), or if boulders were only moved during flooding by exceptional winter storms.

  7. Monolithic Integrated Radiation Sensor Using Stimulated Luminescence From Alumina

    NASA Technical Reports Server (NTRS)

    McKeever, S. W. S.; Yukihara, E. G.; Stoebe, T. G.; Chen, T.-C.

    2005-01-01

    The project goal was to design and test a monolithic integrated device for radiation sensing, using optically stimulated luminescence (OSL) from Al2O3:C. The device would consist of GaN/InGaN-based components epitaxially grown on each side of a A12O3:C substrate. Radiation energy stored in the substrate would be stimulated by visible emission from a GaN light-emitting diode (LED) grown on one side of the device, and the OSL emission from the substrate (in the blue region of the spectrum) would be detected by the InGaN pi-n diode grown on the other side of the substrate. The primary application of the device would be in space radiation environments. Thus, two major research thrusts were launched during this project. Firstly, research at Oklahoma State University (Dr. Stephen W.S. McKeever and Dr. E.G. Yukihara) concentrated on characterization of the OSL properties of Al2O3:C in radiation fields typical of those experienced in low-Earth orbit. Secondly, research at the University of Washington (Co-Is, Dr. T.G. Stoebe and Dr. T. Chen) focused of device development and GaN/InGaN epitaxial growth. While progress in each line of research has been substantial, the ultimate goal (that of producing a working prototype device) has not yet been reached. We detail the research progress and identify outstanding issues in this paper.

  8. Proceedings of the First Annual NRO-OSL/GSFC-ATS Rideshare Conference

    NASA Technical Reports Server (NTRS)

    Cutlip, William (Editor)

    1999-01-01

    This document contains the proceedings of the First Annual NRO-OSL/GSFC-ATS Rideshare Conference. The conference was held April 16-16, 1999, at the Litton/TASC Facility, Dulles, Virginia, and was co-chaired by William Cutlip, Goddard Space Flight Center Access to Space Group, and Jim Liller, National Reconnaissance Office, Office of Space Launch.

  9. Optically stimulated luminescence in Cu+ doped lithium orthophosphate

    NASA Astrophysics Data System (ADS)

    Barve, R. A.; Patil, R. R.; Moharil, S. V.; Bhatt, B. C.; Kulkarni, M. S.

    2015-02-01

    Optically stimulated luminescence (OSL) in Cu+ doped Li3PO4 synthesized by co-precipitation technique using different phosphorus precursors was studied. Changes in the luminescent properties were observed with change in the phosphorus precursors. All the synthesized phosphors showed intense fading but the OSL sensitivity was comparable to that of the commercially available Al2O3:C (Landauer Inc.). In general, BSL (blue stimulated luminescence) decay was very fast but the GSL (green stimulated luminescence) decay was comparable to that of Al2O3:C phosphor. Phosphors with fast decay, good sensitivity and intense fading are suitable for real-time dosimetry. Therefore, Cu-doped Li3PO4 could be developed for real-time dosimetry using a fiber optic based OSL reader system.

  10. OSL dating of a Pleistocene maar: Birket Ram, the Golan heights

    USGS Publications Warehouse

    Shaanan, U.; Porat, N.; Navon, O.; Weinberger, R.; Calvert, A.; Weinstein, Y.

    2011-01-01

    Direct dating of maars and their phreatomagmatic deposits is difficult due to the dominance of lithic (host rock) fragments and glassy particles of the juvenile magma. In this paper we demonstrate that optically stimulated luminescence (OSL) dating can be successfully used for age determination of phreatomagmatic deposits. We studied the tuff deposit of Birket Ram, a basanitic maar located at the northern edge of the Golan heights on the western Arabian plate. The maar is underlain by a thick section of Pleistocene basalts, and currently hosts a small lake. It is filled by approximately 90m of lacustrine sediments with radiocarbon ages extrapolated to 108ka at the base. OSL was applied to quartz grains extracted from tuffs and paleosols in order to set the time frame of the phreatomagmatism at the site. A maximum age constraint of 179??13ka was determined for a paleosol that underlies the maar ejecta. Quartz grains from two layers in the tuff section yielded a direct age of 129??6ka for the phreatomagmatic eruption. A younger age of 104??7ka, which was determined for a tuff layer underlying a basaltic flow, was attributed to thermal resetting during the lava emplacement. This was confirmed by an 40Ar/39Ar age of 101??3ka determined on the overlying basalt. The internal consistency of the OSL ages and the agreement with the 40Ar/39Ar age determination as well as with previous estimates demonstrates the potential of OSL for maar dating. ?? 2010 Elsevier B.V.

  11. Practical calibration curve of small-type optically stimulated luminescence (OSL) dosimeter for evaluation of entrance skin dose in the diagnostic X-ray region.

    PubMed

    Takegami, Kazuki; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi; Maehata, Itsumi; Kanazawa, Yuki; Okazaki, Tohru; Kobayashi, Ikuo

    2015-07-01

    For X-ray diagnosis, the proper management of the entrance skin dose (ESD) is important. Recently, a small-type optically stimulated luminescence dosimeter (nanoDot OSL dosimeter) was made commercially available by Landauer, and it is hoped that it will be used for ESD measurements in clinical settings. Our objectives in the present study were to propose a method for calibrating the ESD measured with the nanoDot OSL dosimeter and to evaluate its accuracy. The reference ESD is assumed to be based on an air kerma with consideration of a well-known back scatter factor. We examined the characteristics of the nanoDot OSL dosimeter using two experimental conditions: a free air irradiation to derive the air kerma, and a phantom experiment to determine the ESD. For evaluation of the ability to measure the ESD, a calibration curve for the nanoDot OSL dosimeter was determined in which the air kerma and/or the ESD measured with an ionization chamber were used as references. As a result, we found that the calibration curve for the air kerma was determined with an accuracy of 5 %. Furthermore, the calibration curve was applied to the ESD estimation. The accuracy of the ESD obtained was estimated to be 15 %. The origin of these uncertainties was examined based on published papers and Monte-Carlo simulation. Most of the uncertainties were caused by the systematic uncertainty of the reading system and the differences in efficiency corresponding to different X-ray energies.

  12. Thermoluminescence and optically stimulated luminescence properties of Dy3+-doped CaO-Al2O3-B2O3-based glasses

    NASA Astrophysics Data System (ADS)

    Yahaba, T.; Fujimoto, Y.; Yanagida, T.; Koshimizu, M.; Tanaka, H.; Saeki, K.; Asai, K.

    2017-02-01

    We developed Dy3+-doped CaO-Al2O3-B2O3 based glasses with Dy concentrations of 0.5, 1.0, and 2.0 mol% using a melt-quenching technique. The as-synthesized glasses were applicable as materials exhibiting thermoluminescence (TL) and optically stimulated luminescence (OSL). The optical and radiation response properties of the glasses were characterized. In the photoluminescence (PL) spectra, two emission bands due to the 4F9/2 → 6H15/2 and 4F9/2 → 6H13/2 transitions of Dy3+ were observed at 480 and 580 nm. In the OSL spectra, the emission band due to the 4F9/2 → 6H15/2 transition of Dy3+ was observed. Excellent TL and OSL responses were observed for dose ranges of 0.1-90 Gy. In addition, TL fading behavior was better than that of OSL in term of the long-time storage. These results indicate that the Dy3+-doped CaO-Al2O3-B2O3-based glasses are applicable as TL materials.

  13. TL and OSL properties of Mn2+-doped MgGa2O4 phosphor

    NASA Astrophysics Data System (ADS)

    Luchechko, A.; Zhydachevskyy, Ya; Maraba, D.; Bulur, E.; Ubizskii, S.; Kravets, O.

    2018-04-01

    The oxide MgGa2O4 spinel ceramics doped with Mn2+ ions was synthesized by a solid-state reaction at 1200 °C in air. The activator concentration was equal 0.05 mol% of MnO. Phase purity of the synthesized samples was analyzed by X-ray diffraction technique. This spinel ceramics show efficient green emission in the range from 470 to 550 nm with a maximum at about 505 nm under UV or X-ray excitations, which is due to Mn2+ ions. MgGa2O4: Mn2+ exhibits intense thermoluminescence (TL) and optically stimulated luminescence (OSL) after influence of ionizing radiation. Are complex nature of the TL glow curves is associated with a significant number of structural defects that are responsible for the formation of shallow and deep electron traps. In this work, time-resolved OSL characteristics of the samples exposed to beta particles are reported for the first time. A light from green LED was used for optical stimulation. Obtained TL and OSL results suggest MgGa2O4:Mn2+ as perspective material for further research and possible application in radiation dosimetry.

  14. Luminescence chronology of the loess record from the Tönchesberg section - a comparison of using quartz and feldspar as dosimeter to extend the age range beyond the Eemian

    NASA Astrophysics Data System (ADS)

    Dorothe Schmidt, Esther; Frechen, Manfred; Murray, Andrew S.; Tsukamoto, Sumiko

    2010-05-01

    The loess-paleosol sequences of the Tönchesberg section, located in the East Eifel Volcanic field (Germany) provide an excellent climate archive of the late Middle and the Upper Pleistocene in the Middle Rhine area. Loess deposits from the last Glacial (Würmian) and the penultimate Glacial (Rissian) are up to 12 m and 15 m thick, respectively, and intercalated by palaeosols. Optically stimulated luminescence (OSL), thermally transferred optically stimulated luminescence (TT-OSL) and infrared stimulated luminescence (IRSL) measurements were carried out on 14 samples from the Tönchesberg section to determine the deposition age and to set up a more reliable chronological framework for the penultimate and last interglacial-glacial cycle. The fine-grained quartz OSL and polymineral IRSL ages are in good agreement with each other and also with the geologically estimated age, but the quartz TT-OSL ages are overestimated. The OSL and IRSL ages range from 16.8 ± 1.2 to 189 ± 16 ka indicating that the youngest loess and the weakly developed soils were deposited during marine isotope stage (MIS) 2 and 3 and that the two marker loess were most likely accumulated in the transition MIS 4/5. Loess and reworked loess postdating the Eemian soil yield ages of 110-115 ka indicating that these deposits very likely correlate to MIS 5d. Loess deposits taken below the Eemian soil are attributed to the transition MIS 6/7. A weakly developed soil above the Tönchesberg scoria yield an age of 189 ± 16 ka indicating an interstadial soil formation during MIS 7. This is in good agreement with preliminary 40Ar/39Ar-ages for the Tönchesberg scoria and the intercalated tephra layers. Reliable age estimates up to ~70 ka could be obtained using quartz OSL and up to ~190 ka using the pulsed post-IR IR signal from feldspar. Hence the infrared stimulated luminescence (IRSL) is considered as the best approach to date the loess from the Middle Rhine area > 70 ka.

  15. SU-E-T-87: The Effect of Bleaching Wavelengths on the Regeneration of the Optically Stimulated Luminescence Signal of NanoDot Dosimeters Pre-Exposed to High-Doses.

    PubMed

    Omotayo, A; Cygler, J; Sawakuchi, G

    2012-06-01

    To investigate the effect of bleaching wavelengths on the regeneration of optically stimulated luminescence (OSL) signals in Al 2 O 3 :C nanoDot dosimeters pre-exposed to high doses. Regeneration is the increase in the OSL signal during storage of a bleached nanoDot that was previously pre-exposed to a high dose. This phenomenon affects the accuracy of a calibration protocol proposed by Jursinic 2010 (Med. Phys. 37:102) in which pre-exposure of nanoDots to a high-dose was used to minimize changes in the sensitivity of the detector as a function of accumulated dose. Al 2 O 3 :C OSLDs of the type nanoDot were used throughout this study. Readout was performed using the microStar reader. Bleaching of the OSLDs was performed with four 26 W fluorescent light bulbs in two modes: (i) directly under the lamps; and (ii) with the aid of a long-pass optical filter placed over the nanoDots, partially blocking wavelengths below 495 nm. Eighteen nanoDots were pre-exposed to 1 kGy dose. Then the pre-exposed nanoDots were bleached in two sets of 9 to very low residual OSL signals using bleaching modes (i) and (ii) for 12 h and 45 h, respectively. The nanoDots were then stored in dark and readout after various time intervals to monitor the regeneration of the OSL signal. We fitted the regeneration of the OSL signal using a saturation function and obtained rise-time values of 563 h and 630 h, for bleaching modes (i) and (ii), respectively. At the saturation level, the equivalent doses were about 1.18 Gy and 0.38 Gy for modes (i) and (ii), respectively. The regeneration rates of nanoDot OSLDs pre-exposed to high doses depend on the bleaching light wavelength used to reset the detectors. A bleaching source that has a low component of wavelengths below 495 nm can minimize the regeneration of the OSL signal. Natural Sciences and Engineering Research Council of Canada. © 2012 American Association of Physicists in Medicine.

  16. Luminescence ages for alluvial-fan deposits in Southern Death Valley: Implications for climate-driven sedimentation along a tectonically active mountain front

    USGS Publications Warehouse

    Sohn, M.F.; Mahan, S.A.; Knott, J.R.; Bowman, D.D.

    2007-01-01

    Controversy exists over whether alluvial-fan sedimentation along tectonically active mountain fronts is driven by climatic changes or tectonics. Knowing the age of sedimentation is the key to understanding the relationship between sedimentation and its cause. Alluvial-fan deposits in Death Valley and throughout the arid southwestern United States have long been the subjects of study, but their ages have generally eluded researchers until recently. Most mapping efforts have recognized at least four major relative-age groupings (Q1 (oldest), Q2, Q3, and Q4 (youngest)), using observed changes in surface soils and morphology, relation to the drainage net, and development of desert pavement. Obtaining numerical age determinations for these morphologic stages has proven challenging. We report the first optically stimulated luminescence (OSL) ages for three of these four stages deposited within alluvial-fans along the tectonically active Black Mountains of Death Valley. Deposits showing distinct, remnant bar and swale topography (Q3b) have OSL ages from 7 to 4 ka., whereas those with moderate to poorly developed desert pavement and located farther above the active channel (Q3a) have OSL ages from 17 to 11 ka. Geomorphically older deposits with well-developed desert pavement (Q2d) have OSL ages ???25 ka. Using this OSL-based chronology, we note that alluvial-fan deposition along this tectonically active mountain front corresponds to both wet-to-dry and dry-to-wet climate changes recorded globally and regionally. These findings underscore the influence of climate change on alluvial fan deposition in arid and semi-arid regions. ?? 2007 Elsevier Ltd and INQUA.

  17. Optically Stimulated Luminescence Response to Ionizing Radiation of Red Bricks (SiO2, Al2O3, and Fe2O3) Used as Building Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bogard, James S; Espinosa Garcia, Guillermo

    2007-01-01

    Quartz is the most common mineral in our environment. It is found in granite, hydrothermal veins and volcanic rocks, as well as in sedimentary deposits derived from such solid materials. These sediments are also made into building materials, such as bricks and pottery. Thus the potential use of a dose reconstruction technique based on quartz grains is enormous, whether as a dating tool in archaeology and quaternary geology, or in nuclear accident dosimetry. This work describes the Optically Stimulated Luminescence (OSL) response of red brick to ionizing radiation. The bricks, from the state of Puebla, Mexico, represent another class ofmore » materials that can be used in retrospective dosimetry following nuclear or radiological incidents. The chemical composition of fifteen bricks (three samples from five different brick factories) was determined, using energy dispersive spectroscopy (EDS), be primarily SiO{sub 2}, Al{sub 2}O{sub 3} and Fe{sub 2}O{sub 3} and is believed to be representative for this common building material. Individual aliquots from these bricks were powdered in agate mortars and thermally annealed. Replicate samples of the aliquots were then irradiated with beta particles from a sealed source of {sup 90}Sr/{sup 90}Y. The OSL response was measured with a Daybreak Model 2200 High-Capacity OSL Reader System. We present here for this material the characteristic OSL response to beta particles; the reproducibility of the OSL response; the linearity of the response in the dose range 0.47 Gy to 47 Gy; and the fading characteristics.« less

  18. Retrospective dosimetry using OSL of tooth enamel and dental repair materials irradiated under wet and dry conditions.

    PubMed

    Geber-Bergstrand, Therése; Bernhardsson, Christian; Mattsson, Sören; Rääf, Christopher L

    2012-11-01

    Following a radiological or nuclear emergency event, there is a need for quick and reliable dose estimations of potentially exposed people. In situations where dosimeters are not readily available, the dose estimations must be carried out using alternative methods. In the present study, the optically stimulated luminescence (OSL) properties of tooth enamel and different dental repair materials have been examined. Specimens of the materials were exposed to gamma and beta radiation in different types of liquid environments to mimic the actual irradiation situation in the mouth. Measurements were taken using a Risø TL/OSL reader, and irradiations were made using a (90)Sr/(90)Y source and a linear accelerator (6 MV photons). Results show that the OSL signal from tooth enamel decreases substantially when the enamel is kept in a wet environment. Thus, tooth enamel is not reliable for retrospective dose assessment without further studies of the phenomenon. Dental repair materials, on the other hand, do not exhibit the same effect when exposed to liquids. In addition, dose-response and fading measurements of the dental repair materials show promising results, making these materials highly interesting for retrospective dosimetry. The minimum detectable dose for the dental repair materials has been estimated to be 20-185 mGy.

  19. Germanium-doped optical fiber for real-time radiation dosimetry

    NASA Astrophysics Data System (ADS)

    Mizanur Rahman, A. K. M.; Zubair, H. T.; Begum, Mahfuza; Abdul-Rashid, H. A.; Yusoff, Z.; Ung, N. M.; Mat-Sharif, K. A.; Wan Abdullah, W. S.; Amouzad Mahdiraji, Ghafour; Amin, Y. M.; Maah, M. J.; Bradley, D. A.

    2015-11-01

    Over the past three decades growing demand for individualized in vivo dosimetry and subsequent dose verification has led to the pursuit of newer, novel and economically feasible materials for dosimeters. These materials are to facilitate features such as real-time sensing and fast readouts. In this paper, purposely composed SiO2:Ge optical fiber is presented as a suitable candidate for dosimetry. The optical fiber is meant to take advantage of the RL/OSL technique, providing both online remote monitoring of dose rate, and fast readouts for absorbed dose. A laboratory-assembled OSL reader has been used to acquire the RL/OSL response to LINAC irradiations (6 MV photons). The notable RL characteristics observed include constant level of luminescence for the same dose rate (providing better consistency compared to TLD-500), and linearity of response in the radiotherapy range (1 Gy/min to 6 Gy/min). The OSL curve was found to conform to an exponential decay characteristic (illumination with low LED source). The Ge doping resulted in an effective atomic number, Zeff, of 13.5 (within the bone equivalent range). The SiO2:Ge optical fiber sensor, with efficient coupling, can be a viable solution for in vivo dosimetry, besides a broad range of applications.

  20. Unprecedented last-glacial mass accumulation rates determined by luminescence dating of loess from western Nebraska

    USGS Publications Warehouse

    Roberts, H.M.; Muhs, D.R.; Wintle, A.G.; Duller, G.A.T.; Bettis, E. Arthur

    2003-01-01

    A high-resolution chronology for Peoria (last glacial period) Loess from three sites in Nebraska, midcontinental North America, is determined by applying optically stimulated luminescence (OSL) dating to 35-50 ??m quartz. At Bignell Hill, Nebraska, an OSL age of 25,000 yr near the contact of Peoria Loess with the underlying Gilman Canyon Formation shows that dust accumulation occurred early during the last glacial maximum (LGM), whereas at Devil's Den and Eustis, Nebraska, basal OSL ages are significantly younger (18,000 and 21,000 yr, respectively). At all three localities, dust accumulation ended at some time after 14,000 yr ago. Mass accumulation rates (MARs) for western Nebraska, calculated using the OSL ages, are extremely high from 18,000 to 14,000 yr-much higher than those calculated for any other pre-Holocene location worldwide. These unprecedented MARs coincide with the timing of a mismatch between paleoenvironmental evidence from central North America, and the paleoclimate simulations from atmospheric global circulation models (AGCMs). We infer that the high atmospheric dust loading implied by these MARs may have played an important role, through radiative forcing, in maintaining a colder-than-present climate over central North America for several thousand years after summer insolation exceeded present-day values. ?? 2003 Elsevier Science (USA). All rights reserved.

  1. The applicability of OSL as a sedimentological proxy: new avenues to distinguish extreme events

    NASA Astrophysics Data System (ADS)

    Lopez, G. I.

    2012-12-01

    Signature underwater tsunami deposits have been relatively recently found in the upper Mediterranean shelf offshore Israel. They have been attributed as a potential cause for the demise of the ancient Roman city of Caesarea Maritima and its artificial Herodian harbour of Sebastos. Present annual large winter storm activity (2010-2011; waves heights up to 14 m) has severely impacted the area, showing increased coastal erosion and rigorous movement of nearshore sands, complicating the stratigraphical histories of the near offshore record. Recent sedimentological and geoarchaeological studies conducted in and around the harbour have been aimed to investigate extreme event characterization by different means, using Optically Stimulated Luminescence (OSL). A comparative study of modern and palaeo-storm sediments was launched in order to obtain physical correlation between offshore sediments, enabling further comparison with historical tsunami deposits, as well as modern and ancient sands emplaced during normal marine conditions. A suite of previously collected and identified sediment samples was selected from the same area where the modern storm analogues were collected. The palaeo-samples came from long-vertical hydraulic percussion cores (14-30 m depths) and small horizontal tubes pushed into excavated underwater sediment walls (2-12 m depths). The uniqueness of OSL relays on its capacity to date the last time a mineral grain was effectively exposed to sunlight, just prior to its burial. It is intrinsically related to final depositional process, which should reflect the completeness of the OSL signal resetting (zeroing process), evidenced by the normality and modality of the Equivalent Dose (DE) distribution. In Optical Dating, DE over-dispersion values have been used as a measure of inhomogeneitiy in the natural palaeo-dose of sediments. Such heterogeneity can be due to an array of causes, including insufficient zeroing during transport and deposition, or turbation processes after burial. Environments where sediments are well exposed to daylight at deposition (e.g. aeolian and some coastal) do not show extreme over-dispersion values but rather well clustered DE's as noted by probability-distribution plots. The degrees of variance and skewness of Gaussian or relative-probability distributions are intrinsically related to the scatter factor. Hence, the latter could be used to differentiate between depositional mechanisms and/or environmental settings. In this study, the single-aliquot regenerative-dose (SAR) protocol was used to measure the OSL signals from single grains of quartz from tsunami, storm and normal marine conditions deposits. Over-dispersion analyses were conducted on all samples. Preliminary results suggest the possibility of differentiating between all three types of deposits based on pre-established over-dispersion values and representative single-dose population distributions. Further comparative OSL experiments are currently being carried out on other known tsunamigenic analogues to further evaluate OSL signal behaviours and constrain the findings (2011 Tohoku Tsunami; 1979 night Petatlán Tsunami). Rather than a dating tool, OSL was used to identify signal patterns exclusive to known depositional conditions, in hope of applying it as sedimentological proxy in event stratigraphy and palaeoseismic tsunami research.

  2. Investigating Advances in the Acquisition of Systems Based on Open Architecture and Open Source Software

    DTIC Science & Technology

    2011-08-01

    dominates the global mobile application market and mobile computing software ecosystems. But overall, OA systems are not necessarily excluded from...License 3.0 (OSL)  Corel Transactional License ( CTL ) The licenses were chosen to represent a variety of kinds of licenses, and include one...proprietary ( CTL ), three academic (Apache, BSD, MIT), and six reciprocal licenses (CPL, EPL, GPL, LGPL, MPL, OSL) that take varying approaches in

  3. TL, OSL and C-14 dating results of the sediments and bricks from mummified nuns' grave.

    PubMed

    Tudela, Diego R G; Tatumi, Sonia H; Yee, Márcio; Brito, Silvio L M; Morais, José L; Morais, Daisy de; Piedade, Silvia C; Munita, Casimiro S P; Hazenfratz, Roberto

    2012-06-01

    This paper presents the results of TL and OSL dating of soil and fragments of bricks from a grave, which was occupied by two mummified nuns, found at "Luz" Monastery, located in the state of São Paulo, Brazil. The TL and OSL ages were compared to C-14 dating ones obtained from bone collagens of the mummies. The majority of the ages is related to the eighteenth century. The gamma-ray spectroscopy was used to evaluate natural radioisotope concentrations in the samples, and by using these concentrations the annual dose rates, from 3.0 to 5.3 Gy/kyr, were obtained. Neutron activation analysis was performed and the radioisotope contents results are in agreement with those obtained by gamma-ray spectroscopy. The contents of U, Th and Ce elements were higher than those found in usual sediments.

  4. Luminescence quartz dating of lime mortars. A first research approach.

    PubMed

    Zacharias, N; Mauz, B; Michael, C T

    2002-01-01

    Lime mortars mixed with sand are well suited for connecting structural materials, like stones and bricks, due to the mechanical properties this material exhibits. Their extensive use in architectural and decorative works during the last 4000 years motivated the introduction of the 'Luminescence clock' for age determination of mortars. The same principles as for quartz optically stimulated luminescence (OSL) dating of sediments were applied for age estimation of a mortar fragment removed from a Byzantine church monument dated by archaeological means to 1050-1100 years ago (the first half of the 10th century). The OSL from the quartz was monitored under blue light stimulation and UV detection, using a single-aliquot-regenerative-dose protocol. The quartz-OSL dating of the mortar resulted in 870 +/- 230 a. TL polymineral fine grain dating was also performed on a brick fragment which was connected to the mortar, resulting in a TL age of 1095 +/- 190 a.

  5. Synthesis and luminescence properties of KSrPO4:Eu2+ phosphor for radiation dosimetry

    NASA Astrophysics Data System (ADS)

    Palan, C. B.; Bajaj, N. S.; Omanwar, S. K.

    2016-05-01

    The KSrPO4:Eu phosphor was synthesized via solid state method. The structural and morphological characterizations were done through XRD (X-ray diffraction) and SEM (Scanning Electronic Microscope). Additionally, the photoluminescence (PL), thermoluminescence (TL) and optically Stimulated luminescence (OSL) properties of powder KSrPO4:Eu were studied. The PL spectra show blue emission under near UV excitation. It was advocated that KSrPO4:Eu phosphor not only show OSL sensitivity (0.47 times) but also gives faster decay in OSL signals than that of Al2O3:C (BARC) phosphor. The TL glow curve consist of two shoulder peaks and the kinetics parameters such as activation energy and frequency factors were determined by using peak shape method and also photoionization cross-sections of prepared phosphor was calculated. The radiation dosimetry properties such as minimum detectable dose (MDD), dose response and reusability were reported.

  6. Surface dose measurement for helical tomotherapy.

    PubMed

    Snir, Jonatan A; Mosalaei, Homeira; Jordan, Kevin; Yartsev, Slav

    2011-06-01

    To compare the surface dose measurements made by different dosimeters for the helical tomotherapy (HT) plan in the case of the target close to the surface. Surface dose measurements in different points for the HT plan to deliver 2 Gy to the planning target volume (PTV) at 5 mm below the surface of the cylindrical phantom were performed by radiochromic films, single use metal oxide semiconductor field-effect transistor (MOSFET) dosimeters, silicon IVD QED diode, and optically stimulated luminescence (OSL) dosimeters. The measured doses by all dosimeters were within 12 +/- 8% difference of each other. Radiochromic films, EBT, and EBT2, provide high spatial resolution, although it is difficult to get accurate measurements of dose. Both the OSL and QED measured similar dose to that of the MOSFET detectors. The QED dosimeter is promising as a reusable on-line wireless dosimeter, while the OSL dosimeters are easier to use, require minimum setup time and are very precise.

  7. Chronology of Quaternary coastal aeolianite deposition and the drowned shorelines of southwestern Western Australia - a reappraisal

    NASA Astrophysics Data System (ADS)

    Brooke, B. P.; Olley, J. M.; Pietsch, T.; Playford, P. E.; Haines, P. W.; Murray-Wallace, C. V.; Woodroffe, C. D.

    2014-06-01

    Aeolianite successions of low-gradient continental margins commonly show complex records of coastal dune deposition linked to a wide range of sea-level positions and climatic periods of the middle and late Pleistocene, recording both regional and broader-scale drivers of sediment production, coastal dune development and landform preservation. To better characterise the general pattern of sedimentation that occurs over Quaternary glacial-interglacial cycles on low-gradient, temperate carbonate continental shelves we examine the morphology, stratigraphy and age of aeolianite deposits in the Perth region, Western Australia. This includes an analysis of well-defined drowned coastal landforms preserved on the adjacent shelf. New and previously published optical ages provide a preliminary timeframe for the deposition of aeolianite in the Perth region and on Rottnest Island, 17 km offshore. An extensive aeolianite ridge near Perth, representing a former barrier, has Optically Stimulated Luminesence (OSL) ages that range from 120 ± 12 to 103 ± 10 ka (MIS 5e-5a in the context of associated age uncertainties). OSL ages for an exposure in the same ridge 2.5 km inland, record the onlap of much older aeolianite, OSL age 415 ± 70 ka, by shell-rich estuarine beds, OSL age 290 ± 30 ka. A further 5.5 km inland from the coast, two thick aeolianite units, separated by a well-developed palaeosol, have stratigraphically consistent OSL ages of 310 ± 30 and 155 ± 20 ka. In contrast, aeolianite units that form the northern coast of Rottnest Island have OSL ages of 77 ± 12 ka and 27 ± 5 ka. The new OSL ages and previously reported TL and U/Th ages indicate that the bulk of the island comprises dunes deposited around the end of the Last Interglacial sensu lato (MIS 5a-4) and during the Last Glacial (MIS 4-2), accumulating over a Last Interglacial coral reef and basal calcarenite. Drowned barrier and dune landforms preserved on the adjacent continental shelf reveal that barriers were formed during periods of intermediate sea level (e.g. MIS 3) and significant dune mobility occurred when the shelf was subaerially exposed. The pattern of shelf sedimentation discernible in the Perth region - large-scale coastal carbonate dune deposition during periods of high and intermediate sea level and reactivation during glacial lowstands - is largely consistent with published stratigraphic and age data for large-scale aeolianite deposits on other low-gradient carbonate shelves. Based on these data, a general model is proposed for the cycle of Quaternary sedimentation and landform evolution that occurs on these shelves, which are dynamic sedimentary environments with coastal landforms and sedimentary successions that are very sensitive to erosion and sediment reworking.

  8. Measurement of dose given by Co-60 in radiotherapy with TLD-500

    NASA Astrophysics Data System (ADS)

    Tanır, Güneş; Cengiz, Ferhat; Hicabi Bölükdemir, M.

    2012-04-01

    The uses of dosimeters based on optically stimulated luminescence technique have become widespread in clinical applications. In the present study, the dose values given by Cobalt-60 radiotherapy machine were measured with optically stimulated luminescence (OSL) technique using TLD-500 and compared with those of commonly used ionization chamber dosimeter system. The percentage depth dose (DD%) values and graphs were formed. OSL system with TLD-500 can be reliably used as medical and personal dosimeter.

  9. An affordable optically stimulated luminescent dosimeter reader utilizing multiple excitation wavelengths.

    PubMed

    Kearfott, Kimberlee J; West, W Geoffrey

    2015-10-01

    A lower-cost optically stimulated luminescence (OSL) reader with increased flexibility for pursuing laboratory research into OSL theory and application was designed and constructed. This was achieved by using off-the-shelf optical components and higher-power light emitting diodes. The resulting reader includes more wavelengths of excitation light than current commercial readers, as well as the ability to swap out filters and other components during an experiment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Performance and stability of an expanded granular sludge bed reactor modified with zeolite addition subjected to step increases of organic loading rate (OLR) and to organic shock load (OSL).

    PubMed

    Pérez-Pérez, T; Pereda-Reyes, I; Pozzi, E; Oliva-Merencio, D; Zaiat, M

    2018-01-01

    This paper shows the effect of organic shock loads (OSLs) on the anaerobic digestion (AD) of synthetic swine wastewater using an expanded granular sludge bed (EGSB) reactor modified with zeolite. Two reactors (R1 and R2), each with an effective volume of 3.04 L, were operated for 180 days at a controlled temperature of 30 °C and hydraulic retention time of 12 h. In the case of R2, 120 g of zeolite was added. The reactors were operated with an up-flow velocity of 6 m/h. The evolution of pH, total Kjeldahl nitrogen, chemical oxygen demand (COD) and volatile fatty acids (VFAs) was monitored during the AD process with OSL and increases in the organic loading rate (OLR). In addition, the microbial composition and changes in the structure of the bacterial and archaeal communities were assessed. The principal results demonstrate that the presence of zeolite in an EGSB reactor provides a more stable process at higher OLRs and after applying OSL, based on both COD and VFA accumulation, which presented with significant differences compared to the control. Denaturing gradient gel electrophoresis band profiles indicated differences in the populations of Bacteria and Archaea between the R1 and R2 reactors, attributed to the presence of zeolite.

  11. Measurement of radiation dose with BeO dosimeters using optically stimulated luminescence technique in radiotherapy applications.

    PubMed

    Şahin, Serdar; Güneş Tanır, A; Meriç, Niyazi; Aydınkarahaliloğlu, Ercan

    2015-09-01

    The radiation dose delivered to the target by using different radiotherapy applications has been measured with the help of beryllium oxide (BeO) dosimeters to be placed inside the rando phantom. Three-Dimensional Conformal Radiotherapy (3DCRT), Intensity-Modulated Radiotherapy (IMRT) and Intensity-Modulated Arc Therapy (IMAT) have been used as radiotherapy application. Individual treatment plans have been made for the three radiotherapy applications of rando phantom. The section 4 on the phantom was selected as target and 200 cGy doses were delivered. After the dosimeters placed on section 4 (target) and the sections 2 and 6 (non-target) were irradiated, the result was read through the OSL technique on the Risø TL/OSL system. This procedure was repeated three times for each radiotherapy application. The doses delivered to the target and the non-target sections as a result of the 3DCRT, IMRT and IMAT plans were analyzed. The doses received by the target were measured as 204.71 cGy, 204.76 cGy and 205.65 cGy, respectively. The dose values obtained from treatment planning system (TPS) were compared to the dose values obtained using the OSL technique. It has been concluded that, the radiation dose can be measured with the OSL technique by using BeO dosimeters in medical practices. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Dating Saharan dust deposits on Lanzarote (Canary Islands) by luminescence dating techniques and their implication for palaeoclimate reconstruction of NW Africa

    NASA Astrophysics Data System (ADS)

    von Suchodoletz, H.; Fuchs, M.; ZöLler, L.

    2008-02-01

    Lava flow dammed valleys (Vegas) on Lanzarote (Canary Islands) represent unique sediment traps, filled with autochthonous volcanic material and allochthonous Saharan dust. These sediments and the intercalated palaeosoil sediments document past environmental change of the last glacial-interglacial cycles, both on Lanzarote and in NW Africa. A reliable chronology must be established to use these sediment archives for palaeoclimate reconstructions. Owing to the lack of organic material and the limiting time range of the 14C-dating method, luminescence dating is the most promising method for these sediments. However, the fluvio-eolian character of these sediments is a major problem for luminescence dating, because these sediments are prone to insufficient resetting of the parent luminescence signal (bleaching) prior to sedimentation. To check for the best age estimates, we compare the bleaching behavior of (1) different grain sizes (coarse- versus fine-grain quartz OSL) and (2) different minerals (fine-grain feldspar IRSL versus fine-grain quartz OSL). The results show that owing to its bleaching characteristics, quartz is the preferable mineral for luminescence dating. On the basis of the fine- and coarse-grain quartz OSL age estimates, a chronostratigraphy up to 100 ka could be established. Beyond this age limit for OSL quartz, the chronostratigraphy could be extended up to 180 ka by correlating the vega sediments with dated marine sediment archives.

  13. Effective noise-suppressed and artifact-reduced reconstruction of SPECT data using a preconditioned alternating projection algorithm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Si; Xu, Yuesheng, E-mail: yxu06@syr.edu; Zhang, Jiahan

    Purpose: The authors have recently developed a preconditioned alternating projection algorithm (PAPA) with total variation (TV) regularizer for solving the penalized-likelihood optimization model for single-photon emission computed tomography (SPECT) reconstruction. This algorithm belongs to a novel class of fixed-point proximity methods. The goal of this work is to investigate how PAPA performs while dealing with realistic noisy SPECT data, to compare its performance with more conventional methods, and to address issues with TV artifacts by proposing a novel form of the algorithm invoking high-order TV regularization, denoted as HOTV-PAPA, which has been explored and studied extensively in the present work.more » Methods: Using Monte Carlo methods, the authors simulate noisy SPECT data from two water cylinders; one contains lumpy “warm” background and “hot” lesions of various sizes with Gaussian activity distribution, and the other is a reference cylinder without hot lesions. The authors study the performance of HOTV-PAPA and compare it with PAPA using first-order TV regularization (TV-PAPA), the Panin–Zeng–Gullberg one-step-late method with TV regularization (TV-OSL), and an expectation–maximization algorithm with Gaussian postfilter (GPF-EM). The authors select penalty-weights (hyperparameters) by qualitatively balancing the trade-off between resolution and image noise separately for TV-PAPA and TV-OSL. However, the authors arrived at the same penalty-weight value for both of them. The authors set the first penalty-weight in HOTV-PAPA equal to the optimal penalty-weight found for TV-PAPA. The second penalty-weight needed for HOTV-PAPA is tuned by balancing resolution and the severity of staircase artifacts. The authors adjust the Gaussian postfilter to approximately match the local point spread function of GPF-EM and HOTV-PAPA. The authors examine hot lesion detectability, study local spatial resolution, analyze background noise properties, estimate mean square errors (MSEs), and report the convergence speed and computation time. Results: HOTV-PAPA yields the best signal-to-noise ratio, followed by TV-PAPA and TV-OSL/GPF-EM. The local spatial resolution of HOTV-PAPA is somewhat worse than that of TV-PAPA and TV-OSL. Images reconstructed using HOTV-PAPA have the lowest local noise power spectrum (LNPS) amplitudes, followed by TV-PAPA, TV-OSL, and GPF-EM. The LNPS peak of GPF-EM is shifted toward higher spatial frequencies than those for the three other methods. The PAPA-type methods exhibit much lower ensemble noise, ensemble voxel variance, and image roughness. HOTV-PAPA performs best in these categories. Whereas images reconstructed using both TV-PAPA and TV-OSL are degraded by severe staircase artifacts; HOTV-PAPA substantially reduces such artifacts. It also converges faster than the other three methods and exhibits the lowest overall reconstruction error level, as measured by MSE. Conclusions: For high-noise simulated SPECT data, HOTV-PAPA outperforms TV-PAPA, GPF-EM, and TV-OSL in terms of hot lesion detectability, noise suppression, MSE, and computational efficiency. Unlike TV-PAPA and TV-OSL, HOTV-PAPA does not create sizable staircase artifacts. Moreover, HOTV-PAPA effectively suppresses noise, with only limited loss of local spatial resolution. Of the four methods, HOTV-PAPA shows the best lesion detectability, thanks to its superior noise suppression. HOTV-PAPA shows promise for clinically useful reconstructions of low-dose SPECT data.« less

  14. Effective noise-suppressed and artifact-reduced reconstruction of SPECT data using a preconditioned alternating projection algorithm

    PubMed Central

    Li, Si; Zhang, Jiahan; Krol, Andrzej; Schmidtlein, C. Ross; Vogelsang, Levon; Shen, Lixin; Lipson, Edward; Feiglin, David; Xu, Yuesheng

    2015-01-01

    Purpose: The authors have recently developed a preconditioned alternating projection algorithm (PAPA) with total variation (TV) regularizer for solving the penalized-likelihood optimization model for single-photon emission computed tomography (SPECT) reconstruction. This algorithm belongs to a novel class of fixed-point proximity methods. The goal of this work is to investigate how PAPA performs while dealing with realistic noisy SPECT data, to compare its performance with more conventional methods, and to address issues with TV artifacts by proposing a novel form of the algorithm invoking high-order TV regularization, denoted as HOTV-PAPA, which has been explored and studied extensively in the present work. Methods: Using Monte Carlo methods, the authors simulate noisy SPECT data from two water cylinders; one contains lumpy “warm” background and “hot” lesions of various sizes with Gaussian activity distribution, and the other is a reference cylinder without hot lesions. The authors study the performance of HOTV-PAPA and compare it with PAPA using first-order TV regularization (TV-PAPA), the Panin–Zeng–Gullberg one-step-late method with TV regularization (TV-OSL), and an expectation–maximization algorithm with Gaussian postfilter (GPF-EM). The authors select penalty-weights (hyperparameters) by qualitatively balancing the trade-off between resolution and image noise separately for TV-PAPA and TV-OSL. However, the authors arrived at the same penalty-weight value for both of them. The authors set the first penalty-weight in HOTV-PAPA equal to the optimal penalty-weight found for TV-PAPA. The second penalty-weight needed for HOTV-PAPA is tuned by balancing resolution and the severity of staircase artifacts. The authors adjust the Gaussian postfilter to approximately match the local point spread function of GPF-EM and HOTV-PAPA. The authors examine hot lesion detectability, study local spatial resolution, analyze background noise properties, estimate mean square errors (MSEs), and report the convergence speed and computation time. Results: HOTV-PAPA yields the best signal-to-noise ratio, followed by TV-PAPA and TV-OSL/GPF-EM. The local spatial resolution of HOTV-PAPA is somewhat worse than that of TV-PAPA and TV-OSL. Images reconstructed using HOTV-PAPA have the lowest local noise power spectrum (LNPS) amplitudes, followed by TV-PAPA, TV-OSL, and GPF-EM. The LNPS peak of GPF-EM is shifted toward higher spatial frequencies than those for the three other methods. The PAPA-type methods exhibit much lower ensemble noise, ensemble voxel variance, and image roughness. HOTV-PAPA performs best in these categories. Whereas images reconstructed using both TV-PAPA and TV-OSL are degraded by severe staircase artifacts; HOTV-PAPA substantially reduces such artifacts. It also converges faster than the other three methods and exhibits the lowest overall reconstruction error level, as measured by MSE. Conclusions: For high-noise simulated SPECT data, HOTV-PAPA outperforms TV-PAPA, GPF-EM, and TV-OSL in terms of hot lesion detectability, noise suppression, MSE, and computational efficiency. Unlike TV-PAPA and TV-OSL, HOTV-PAPA does not create sizable staircase artifacts. Moreover, HOTV-PAPA effectively suppresses noise, with only limited loss of local spatial resolution. Of the four methods, HOTV-PAPA shows the best lesion detectability, thanks to its superior noise suppression. HOTV-PAPA shows promise for clinically useful reconstructions of low-dose SPECT data. PMID:26233214

  15. Defining the upper age limit of luminescence dating: A case study using long lacustrine records from Chew Bahir, Ethiopia

    NASA Astrophysics Data System (ADS)

    Chapot, Melissa S.; Roberts, Helen M.; Lamb, Henry F.; Schäbitz, Frank; Asrat, Asfawossen; Trauth, Martin H.

    2017-04-01

    Optically stimulated luminescence (OSL) dating is a family of numerical chronometric techniques applied to quartz or feldspar mineral grains to assess the time since these grains were last exposed to sunlight (i.e. deposited), based on the amount of energy they absorbed from ambient radiation during burial. The maximum limit of any OSL dating technique is not defined by a fixed upper age limit, but instead by the maximum radiation dose the sample can accurately record before the OSL signal saturates. The challenge is to assess this upper limit of accurate age determination without necessitating comparison to independent age control. Laboratory saturation of OSL signals can be observed using a dose response curve (DRC) plotting OSL signal intensity against absorbed laboratory radiation dose. When a DRC is fitted with a single saturating exponential, one of the equation's parameters can be used to define a pragmatic upper limit beyond which uncertainties become large and asymmetric (Wintle and Murray, 2006). However, many sub-samples demonstrate DRCs that are best defined by double saturating exponential equations, which cannot be used to define this upper limit. To investigate the reliability of luminescence ages approaching saturation, Chapot et al. (2012) developed the Natural DRC concept, which uses expected ages derived from independent age control, combined with sample-specific measurements of ambient radioactivity, to calculate expected doses of absorbed radiation during burial. Natural OSL signal intensity is then plotted against these expected doses and compared to laboratory-generated DRCs. Using this approach, discrepancies between natural and laboratory DRCs have been observed for the same mineral material as natural OSL signal intensities saturate at absorbed radiation doses lower than the pragmatic upper limit defined by laboratory DRCs, leading to increasing age underestimation with depth without a metric for questioning the age reliability. The present study explores a means of defining the upper limit for reliable luminescence ages for sedimentary records without an established chronologic framework, using a long ( 280m; Cohen et al., 2016) lacustrine record from Chew Bahir, Ethiopia, drilled as part of the Hominin Sites and Paleolakes Drilling Project (HSPDP) of the International Continental Scientific Drilling Programme (ICDP) and CRC806 "Our way to Europe". Natural saturation of OSL signals is explored by plotting natural signal intensity against depth, creating a pseudo-Natural DRC that can be compared to laboratory DRCs. Unlike the homogenous deposits of the Chinese Loess Plateau where the Natural DRC concept was developed, the 280m composite core from Chew Bahir shows significant variation in lithology enabling investigation of the effects of sample to sample variability on Natural DRC construction, and facilitating comparison between signals from fine-quartz, fine-polymineral, and coarse-potassium feldspar grains. This work demonstrates how the concepts of Natural DRCs can be used to define the upper dating limit of sample suites without independent age control, providing valuable information for long sedimentary sequences such as the lacustrine deposits from Chew Bahir. Chapot M.S., et al. (2012), Radiation Measurements 47: 1045-1052. Cohen A, et al. (2016), Scientific Drilling 21: 1-16. Wintle, A.G., Murray, A.S. (2006) Radiation Measurements 41: 369-391.

  16. Quartz and K-feldspar luminescence dating of sedimentation in the North Bohai coastal area (NE China) since the late pleistocene

    NASA Astrophysics Data System (ADS)

    Li, Yan; Shang, Zhiwen; Tsukamoto, Sumiko; Tamura, Toru; Yi, Liang; Wang, Hong; Frechen, Manfred; Li, Jianfen; Jiang, Xingyu

    2018-02-01

    In this study, luminescence dating of core sediments from the North Bohai Coast (China) was applied to provide a high-resolution chronological constraint, on a better understanding of the Holocene marine-terrestrial interaction. The studied sedimentary sequence contains a terrigenous deposit, a transgressive deposit and a prograding deltaic succession; all are believed to have formed during the late Pleistocene. To establish a reliable luminescence chronology, the luminescence signals of ten samples were investigated in order to quantify the degree of bleaching. This approach involved the use of quartz OSL, K-feldspar infrared stimulated luminescence (IRSL) and post-IR IRSL (pIRIR) ages. The resulting data were then compared with radiocarbon ages. The quartz OSL signals were well-bleached for all the samples, and the feldspar pIRIR150 and pIRIR225 signals yielded reliable ages for the pre-Holocene deposits but overestimated ages for late Holocene deposits (<1000 years). Radiocarbon data appeared to slightly overestimate the age of the young Holocene samples, therefore the chronological framework was established using quartz OSL ages. The early-mid Holocene transgressive deposits are relatively thin, which was attributed to the low-gradient relief and weak riverine fluvial input. Rapid deltaic progradation with high sedimentation rates over the last millennia, was revealed by the quartz OSL age results. This was supported by historical records for this section of the coastline. Episodic deposition around 700 years ago most likely triggered by frequent flooding events, was highlighted by the clustered OSL ages. While the sediment increment was 2.7 × 104 m3 a-1 for the period of ∼6-1 ka, this increased considerably to 9.1 × 106 m3 a-1 during the rapid progradation of the last millennium. The increase appears related to winter monsoon enhancement and human activity during the last 1000 years.

  17. Experimental investigations of OSL signal changes of quartz gouge during low- to high-velocity friction

    NASA Astrophysics Data System (ADS)

    Oohashi, K.; Akasegawa, K.; Hasebe, N.; Miura, K.; Minomo, Y.

    2017-12-01

    Luminescence dating methods such as OSL and TL are mainly used to characterize an age of sediments based on trapping of electron by natural radiation exposure. Recent research suggests its potential applicability for direct age measurement of faulting. The idea behind to the luminescence dating for a determination of paleo-earthquake event is the accumulated natural radiation damage in intra-fault materials becomes to zero by the frictional heating and/or grinding. However, a relationship between fault motion and annihilation of luminescence signals, and its mechanism has not been understood. In this study, we conduct low- to high-velocity friction experiments using quartz gouge under various displacements and moisture conditions to establish an empirical relationship of OSL signal change upon shearing. In the friction experiments, we used quartz grains of <150 μm separated from the Cretaceous granite, taken from the east wall of the Nojima fault Ogura trench site, western Japan, as an analogue gouge. Our results of the OSL measurements are (1) <75 μm fraction of sheared gouge have high fast component ratio than the pre-sheared grains, (2) the fast component ratio of <75 μm fraction increases with increasing slip rate from 200 μm/s to 0.13 m, (3) OSL signal becomes to zero in the experiment sheared under 0.65 m/s. The increase of the fast component ratio found in relatively low slip-rate experiments may be caused by addition of ionized electrons, that emitted from newly formed fracture surface during comminution, in electron center. The signal zeroing observed in the high-velocity friction experiment is attributable to rapid frictional heating up to 700 °C estimated by temperature measurement and calculation. Based on the calculation of frictional energy we added to the experiment sheared under 0.65 m/s, we estimated the zeroing depth in natural conditions of earthquake (1.6 m in displacement) to 192 m.

  18. SU-E-I-60: Validation of An Optically Stimulated Luminescent (OSL) Dosimeter for Use in Output Exposure Control Verification of Mammography Imaging Systems.

    PubMed

    Ranger, R; Butler, P; Yahnke, C; Valentino, D

    2012-06-01

    To develop and validate an Optically Stimulated Luminescent (OSL) dosimeter for exposure control verification of x-ray projection mammography imaging systems. The active detection element of the dosimeter is a strip of OSL material 3.0 mm wide, 0.13 mm thick and 30.0 mm long with an overlying aluminum step wedge with thicknesses of 0, 0.2, 0.4 and 0.6 mm Al, encapsulated in a light-tight plastic enclosure with outer dimensions of 10.0 mm wide, 5.4 mm thick, and 54.0 mm long. The dosimeter is used in conjunction with a breast phantom for the purpose of estimating the half-value layer (HVL), entrance surface exposure (ESE), and average glandular dose (AGD) in conventional projection mammography. ESE and HVL were computed based on analysis of exposure profiles obtained from exposed strip dosimeters. The AGD was estimated by multiplying the ESE by the appropriate exposure to dose conversion factor for the thickness and % glandular tissue fraction represented by the phantom and target-filter combination employed. The accuracy and reproducibility of the ESE, HVL and AGD estimates obtained using the dosimeter positioned on the surface of the ACR phantom at the chest wall edge, was evaluated using mammography systems utilizing different imaging receptor technology, i.e. screen-film (SF), computed radiography (CR) and direct radiography (DR) and compared against results obtained using a calibrated ion chamber fitted with a mammography probe. ESE, AGD and HVL results obtained using the OSL mammography QA dosimeter agreed with results obtained using an ion chamber to within 5-10%, depending on the target-filter combination used. Repeat readings were highly consistent with a coefficient of variation = 5%. The OSL mammography QA dosimeter has been shown to effectively estimate ESE, HVL and AGD, demonstrating its usefulness for secondary monitoring of output exposure of mammography imaging systems. © 2012 American Association of Physicists in Medicine.

  19. OSL properties of three commonly available salt brands in India for its use in accident dosimetry

    NASA Astrophysics Data System (ADS)

    Singh, A. K.; Menon, S. N.; Kadam, S. Y.; Koul, D. K.; Datta, D.

    2018-03-01

    Thermally stimulated luminescence (TL) and Optically Stimulated Luminescence (OSL) characterization of three commonly available salt brands in India were undertaken for their application in accident dosimetry. The investigations showed that the luminescence properties differed to some extent with that reported in literature. Dosimetric properties of these salt samples showed that these can be useful in accident dosimetry. Based on the sensitization and fading behaviour of the samples a Single Aliquot Regenerative (SAR) protocol has been proposed for dose estimation.

  20. Thermal History Using Microparticle Trap Luminescence

    DTIC Science & Technology

    2012-06-01

    measurements were ~erformed using a Rise TL/ OSL -DA-15 reader. Irradiations were carried out using the integrated 0Sr/~0Y beta source delivering a...was obtained using LiF:Mg,Ti dosimeters of dimensions 3 mm x 3 mm x 0.9 mm. A 4-mm thick Kopp 5850 filter and a 3-mm thick HA3 filter were used in...C is one of the most sensitive TL and OSL material available with relatively well-known TL properties (McKeever et al., 1995). Furthermore, its

  1. Design of a finger ring extremity dosemeter based on OSL readout of alpha-Al2O3:C.

    PubMed

    Durham, J S; Zhang, X; Payne, F; Akselrod, M S

    2002-01-01

    A finger-ring dosemeter and reader has been designed that uses OSL readout of alpha-Al2O3:C (aluminium oxide). The use of aluminium oxide is important because it allows the sensitive element of the dosemeter to be a very thin layer that reduces the beta and gamma energy dependence to acceptable levels without compromising the required sensitivity for dose measurement. OSL readout allows the ring dosemeter to be interrogated with minimal disassembly. The ring dosemeter consists of three components: aluminium oxide powder for measurement of dose, an aluminium substrate that gives structure to the ring, and an aluminised Mylar cover to prevent the aluminium oxide from exposure to light. The thicknesses of the three components have been optimised for beta response using the Monte Carlo computer code FLUKA. A reader was also designed and developed that allows the dosemeter to be read after removing the Mylar. Future efforts are discussed.

  2. Developing OSL Geological Dating Techniques for Use on Future Missions to Mars

    NASA Technical Reports Server (NTRS)

    Blair, M. W.; Kalchgruber, R.; Deo, S.; McKeever, S. W. S.

    2005-01-01

    The surface of Mars has been subject to aeolian, fluvial, and periglacial activity in the (relatively) recent past. Unfortunately, chronological dating of recent events on Mars is difficult as the errors associated with crater counting are comparable to younger ages (approx. 1 Ma). Consequently, techniques to quantify the ages of geological processes on Mars have become an important area of research. Optically stimulated luminescence (OSL) dating is one candidate technique for in-situ dating of the deposition of Martian surface sediments. This method can aid in developing a geological and climatic history of the last million years on Mars. The current paper addresses some of the challenges and progress associated with developing OSL as a viable in-situ dating technique for Mars. Some of the challenges include the mineral composition, the effectiveness of solar resetting under Martian conditions, the temperature regime, and determining the natural dose rate on Mars. All of these topics are currently under investigation, and some preliminary results are presented.

  3. Synthesis and luminescence properties of KSrPO{sub 4}:Eu{sup 2+} phosphor for radiation dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palan, C. B., E-mail: chetanpalan27@yahoo.in; Bajaj, N. S.; Omanwar, S. K.

    The KSrPO{sub 4}:Eu phosphor was synthesized via solid state method. The structural and morphological characterizations were done through XRD (X-ray diffraction) and SEM (Scanning Electronic Microscope). Additionally, the photoluminescence (PL), thermoluminescence (TL) and optically Stimulated luminescence (OSL) properties of powder KSrPO{sub 4}:Eu were studied. The PL spectra show blue emission under near UV excitation. It was advocated that KSrPO{sub 4}:Eu phosphor not only show OSL sensitivity (0.47 times) but also gives faster decay in OSL signals than that of Al{sub 2}O{sub 3}:C (BARC) phosphor. The TL glow curve consist of two shoulder peaks and the kinetics parameters such as activationmore » energy and frequency factors were determined by using peak shape method and also photoionization cross-sections of prepared phosphor was calculated. The radiation dosimetry properties such as minimum detectable dose (MDD), dose response and reusability were reported.« less

  4. Thermoluminescence and optically stimulated luminescence disadvantages of α-Al2O3:C crystal grown by the temperature gradient technique

    NASA Astrophysics Data System (ADS)

    Yang, Xin-Bo; Xu, Jun; Li, Hong-Jun; Bi, Qun-Yu; Cheng, Yan; Su, Liang-Bi; Tang, Qiang

    2010-04-01

    Recently, α-Al2O3:C crystal with highly sensitive thermoluminescence (TL) and optically stimulated luminescence (OSL) has been successfully grown by the temperature gradient technique. This paper investigates the heating rate dependence of TL sensitivity, light-induced fading of TL signals and thermal stability of OSL of α-Al2O3:C crystals. As the heating rate increases, the integral TL response decreases and the dosimetric glow peak shifts to higher temperatures in α-Al2O3:C crystals. Light-induced fading of TL increases with the irradiation dose, and TL response decreases as the exposure time increases, especially in the first 15 minutes. With the increasing intensity of the exposure light, the TL fading of α-Al2O3:C crystal increases sharply. The OSL response of as-grown α-Al2O3:C crystal is quite stable below 373 K and decreases sharply for higher temperatures.

  5. Optically stimulated luminescence in an imaging plate using BaFi:Eu.

    PubMed

    Nanto, H; Araki, T; Daimon, M; Kusano, E; Kinbara, A; Kawabata, K; Nakano, Y

    2002-01-01

    BaFI:Eu phosphors are fabricated using a new method of synthesis: liquid phase synthesis, in which the phosphor particles are formed through the association of Ba2+ ions, F-ions and Eu2+ ions in solution. An intense optically stimulated luminescence (OSL) peak at about 410 nm is observed by stimulating X ray irradiated BaFI:Eu phosphor with about 550-750 nm light. It is found that the peak wavelength of the optically stimulation spectrum is about 690 nm. This result suggests that the semiconductor laser can be used as the stimulating light source. It is also found that the OSL intensity is increased with increasing the X ray dose. The BaFI:Eu phosphor as a photostimulable material for the imaging plate of a computed radiography system provides the following advantages; (1) high X ray absorption coefficient, (2) high monodispersion in size which would contribute to sharp images, (3) high OSL and thus low luminescence mottle and (4) high DQE (detective quantum efficiency).

  6. Single-Grain OSL Dating of Early Middle Palaeolithic Deposits at Cuesta de la Bajada, Ebro Basin, Spain

    NASA Astrophysics Data System (ADS)

    Arnold, L. J.; Demuro, M.; Santonja, M.; Perez-Gonzalez, A.

    2012-12-01

    The open-air site of Cuesta de la Bajada comprises a 2-2.5 m-thick sequence of fluvial-lacustrine sediments inset into the +50-60 m terrace deposits preserved along the south-eastern margins of the Alfambra river valley, Teruel, Spain. The main archaeological horizons lie ~20 m above the present-day river level and consists of an upward-fining sequence of massive fluvial silts and fine sands with dispersed gravels, detritic marls and shales that collectively overlie a series of planar bedded fluvial gravels. These units have yielded ~3000 lithic artefacts displaying reduction techniques characteristic of an early Middle Palaeolithic techno-complex, as well as a multitude of faunal remains indicative of a late Middle Pleistocene origin. The paucity of open-air Palaeolithic sites in the interior eastern sector of the Iberian Peninsula, and the relatively low number of documented early Middle Palaeolithic archives in this region, means that Cuesta de la Bajada is of key importance for understanding the coexistence/transition of Iberian Acheulean and Mousterian techno-complexes during the Middle Pleistocene period. Establishing reliable absolute chronologies at Cuesta de la Bajada remains essential for understanding the regional significance of this site. In an attempt to redress the existing chronological uncertainty we are undertaking an interdisciplinary dating study of the Middle Palaeolithic deposits using OSL dating, ESR/U-series dating of teeth and ESR dating of sedimentary quartz. Here we present results obtained using quartz single-grain OSL dating of 4 samples collected from a 7 m vertical profile bracketing the archaeological horizons. 2 samples were collected from the archaeology-bearing silt and fine sand horizons, while the remaining samples were obtained from well-bedded fine-sands and silts 3.5 m above and 3 m below the main excavation. The measured quartz grains are characterised by relatively bright OSL signals and typically display dose-response curves with very high saturation limits. The latter offers the advantage of extending the age range over which single-grain techniques can be applied in this Middle Pleistocene context. Dose-recovery tests performed at high doses of 470 Gy yielded accurate equivalent dose (De) results with low overdispersion, providing reasonable confidence in the chosen measurement conditions. 3 of the samples display single-grain De distributions with low levels of dispersion indicating that the sediments were adequately bleached prior to burial and remained undisturbed thereafter. The fourth sample displays higher De dispersion and a younger subpopulation of grains, which could be explained by beta-dose heterogeneity associated with interspersed gravels within the basal archaeological horizon. We apply various statistical age models to derive final chronologies and compare the resultant single-grain ages with those obtained using different absolute dating methods. We also report on experiments performed using 'synthetic multi-grain aliquots' created from the single-grain De datasets, and discuss their implications for the reliability of multi-grain OSL dating techniques in this context.

  7. Single-grain OSL dating of Early Middle Palaeolithic deposits at Cuesta de la Bajada, Ebro Basin, Spain

    NASA Astrophysics Data System (ADS)

    Arnold, Lee; Demuro, Martina; Santonja, Manuel; Perez-Gonzalez, Alfredo; Pares, Josep

    2013-04-01

    The open-air site of Cuesta de la Bajada comprises a 2-2.5 m-thick sequence of fluvial-lacustrine sediments inset into the +50-60 m terrace deposits preserved along the south-eastern margins of the Alfambra river valley, Teruel, Spain. The main archaeological horizons lie ~20 m above the present-day river level and consists of an upward-fining sequence of massive fluvial silts and fine sands with dispersed gravels, detritic marls and shales that collectively overlie a series of planar bedded fluvial gravels. These units have yielded ~3000 lithic artefacts displaying reduction techniques characteristic of an early Middle Palaeolithic techno-complex, as well as a multitude of faunal remains indicative of a late Middle Pleistocene origin. The paucity of open-air Palaeolithic sites in the interior eastern sector of the Iberian Peninsula, and the relatively low number of documented early Middle Palaeolithic archives in this region, means that Cuesta de la Bajada is of key importance for understanding the coexistence/transition of Iberian Acheulean and Mousterian techno-complexes during the Middle Pleistocene period. Establishing reliable absolute chronologies at Cuesta de la Bajada remains essential for understanding the regional significance of this site. In an attempt to redress the existing chronological uncertainty we are undertaking an interdisciplinary dating study of the Middle Palaeolithic deposits using OSL dating, ESR/U-series dating of teeth and ESR dating of sedimentary quartz. Here we present results obtained using quartz single-grain OSL dating of 4 samples collected from a 7 m vertical profile bracketing the archaeological horizons. 2 samples were collected from the archaeology-bearing silt and fine sand horizons, while the remaining samples were obtained from well-bedded fine-sands and silts 3.5 m above and 3 m below the main excavation. The measured quartz grains are characterised by relatively bright OSL signals and typically display dose-response curves with very high saturation limits. The latter offers the advantage of extending the age range over which single-grain techniques can be applied in this Middle Pleistocene context. Dose-recovery tests performed at high doses of 470 Gy yielded accurate equivalent dose (De) results with low overdispersion, providing reasonable confidence in the chosen measurement conditions. Three of the samples display single-grain De distributions with low levels of dispersion indicating that the sediments were adequately bleached prior to burial and remained undisturbed thereafter. The fourth sample displays higher De dispersion and a younger subpopulation of grains, which could be explained by beta-dose heterogeneity associated with interspersed gravels within the basal archaeological horizon. We apply various statistical age models to derive final chronologies and compare the resultant single-grain ages with those obtained using different absolute dating methods. We also report on experiments performed using 'synthetic multi-grain aliquots' created from the single-grain De datasets, and discuss their implications for the reliability of multi-grain OSL dating techniques in this context.

  8. The benefits of endurance exercise and Tai Chi Chuan for the task-switching aspect of executive function in older adults: an ERP study.

    PubMed

    Fong, Dong-Yang; Chi, Li-Kang; Li, Fuzhong; Chang, Yu-Kai

    2014-01-01

    This study was designed to determine the relationship between physical activity and the task-switching aspect of executive function by investigating the modulating roles of age, modality of physical activity, and type of cognitive function using behavioral and event-related potential (ERP) assessments. Sixty-four participants were assigned to one of four groups based on age and history of physical activity: older adults performing endurance exercise (OEE), older adults practicing Tai Chi Chuan (OTC), older adults with a sedentary lifestyle (OSL), and young adults (YA). Study participants completed a task-switching task under homogeneous and heterogeneous conditions while ERPs were recorded. The results revealed that YA had shortest reaction times compared with the three older adults groups, with OSL exhibiting the longest reaction time. YA also exhibited shorter P3 latency than OSL. No differences were observed in P3 amplitude between YA, OEE, and OTC; however, all three groups had significantly larger P3 amplitude compared with OSL in both task conditions. In conclusion, age and participation in physical activity influence the relationship between physical activity and task-switching, and a positive relationship was observed regardless of the modality of physical activity and type of cognitive function. Our ERP findings support the model of the scaffolding theory of aging and cognition (STAC) and suggest that regular participation in endurance exercise and Tai Chi Chuan may have equivalent beneficial effects on cognition at the behavioral and neuroelectric levels.

  9. The benefits of endurance exercise and Tai Chi Chuan for the task-switching aspect of executive function in older adults: an ERP study

    PubMed Central

    Fong, Dong-Yang; Chi, Li-Kang; Li, Fuzhong; Chang, Yu-Kai

    2014-01-01

    This study was designed to determine the relationship between physical activity and the task-switching aspect of executive function by investigating the modulating roles of age, modality of physical activity, and type of cognitive function using behavioral and event-related potential (ERP) assessments. Sixty-four participants were assigned to one of four groups based on age and history of physical activity: older adults performing endurance exercise (OEE), older adults practicing Tai Chi Chuan (OTC), older adults with a sedentary lifestyle (OSL), and young adults (YA). Study participants completed a task-switching task under homogeneous and heterogeneous conditions while ERPs were recorded. The results revealed that YA had shortest reaction times compared with the three older adults groups, with OSL exhibiting the longest reaction time. YA also exhibited shorter P3 latency than OSL. No differences were observed in P3 amplitude between YA, OEE, and OTC; however, all three groups had significantly larger P3 amplitude compared with OSL in both task conditions. In conclusion, age and participation in physical activity influence the relationship between physical activity and task-switching, and a positive relationship was observed regardless of the modality of physical activity and type of cognitive function. Our ERP findings support the model of the scaffolding theory of aging and cognition (STAC) and suggest that regular participation in endurance exercise and Tai Chi Chuan may have equivalent beneficial effects on cognition at the behavioral and neuroelectric levels. PMID:25389403

  10. Luminescence dating of anthropogenic features of the San Luis Valley, Colorado: from stone huts to stone walls

    USGS Publications Warehouse

    Mahan, Shannon; Donlan, Rebecca A.; Kardos, Barbara Maat

    2015-01-01

    The Snake Nest Wall site and the Crestone Stone Huts are in the northern San Luis Valley, Colorado, and provide a unique opportunity to date high-altitude archeological sites of unknown age and origin using optically stimulated luminescence (OSL). We sampled sediment underlying foundation stones of these structures to establish a chronological framework for each site's construction. OSL dating of the quartz grains directly under the Snake Nest Wall suggest that the stones and, therefore, the structure was most recently emplaced between 1855 and 1890 A.D. Dating of the sediment beneath the Crestone Stone Huts suggests the construction time of these huts is between 1860 and 1890 A.D. Analysis of the equivalent dose (DE) dispersion of the OSL samples at Snake Nest Wall and the Crestone Huts shows that the majority of sediments were fully bleached prior to deposition and the low scatter suggests that short-term or shallow alluvial processes were the dominant transport for sediments. In both cases, the OSL ages show that the construction was during very recent historical times, although it is likely that the Snake Nest Wall was rebuilt in the late 19th century. Further study is warranted at the Snake Nest Wall since it shows signs of greater antiquity and a continued presence of human use. The Crestone Huts are shown to be a product of railroad building during the boomtown days of Lucky and Crestone.

  11. Bioactivity characterization of 45S5 bioglass using TL, OSL and EPR: Comparison with the case of 58S sol-gel bioactive glass.

    PubMed

    Polymeris, G S; Giannoulatou, V; Kyriakidou, A; Sfampa, I K; Theodorou, G S; Şahiner, E; Meriç, N; Kitis, G; Paraskevopoulos, K M

    2017-01-01

    The current work exploits the effective application of thermoluminescence (TL), optically stimulated luminescence (OSL) and the possibility of applying Electron Paramagnetic Resonance (EPR) for the discrimination between different bioactive responses in the case of the 45S5 bioactive glass (SiO 2 45, Na 2 O 24.5, CaO 24.5, P 2 O 5 6 in wt%), which was synthesized through melting process. These techniques are suggested mainly due to their low spectroscopic detection thresholds. The original 45S5 in grain size range of 20-40μm was immersed in the Simulated Body Fluid (SBF) for various different immersion times ranging over one week. In this work the 110°C TL peak, a specific OSL component and the EPR signal at g=2.013 ascribed to oxygen hole center (OHC) are used due to their sensitivity to the different bioactive responses. For all luminescence and EPR components, the intensity plot versus immersion time yields sharp discontinuities, resulting in effective probes regarding the timescale for both the beginning as well as the end of the procedure of the crystalline HCAp formation respectively. On the contrary to the smooth decreasing pattern of both luminescence entities, the peak to peak amplitude of the EPR signal indicates an initial increase for the initial 16min of immersion, followed by a further decrease throughout the immersion time duration. The discontinuities monitored for both sensitivity of TL, OSL and EPR, in conjunction with the discontinuities monitored for the sensitization of TL and OSL, when plotted versus immersion time, provide an individual time scale for each one of the chemical reactions involved in the five steps of the aforementioned procedure. According to the authors' best knowledge, scarce characterization techniques could provide this time scale frame, while it is the first time that such an application of OSL and EPR is attempted. Finally, the bioactive response of the 45S5 bioglass was compared with that of the 58S sol-gel bioactive glass, in terms of the timescale of these five stages required for the final formation of the HCAp. The techniques of luminescence and EPR which take advantage of trapped charges are proposed as alternative cheap and prompt effective techniques towards discrimination between different bioactive responses in bioactive glasses. Copyright © 2016. Published by Elsevier B.V.

  12. A method to acquire CT organ dose map using OSL dosimeters and ATOM anthropomorphic phantoms

    PubMed Central

    Zhang, Da; Li, Xinhua; Gao, Yiming; Xu, X. George; Liu, Bob

    2013-01-01

    Purpose: To present the design and procedure of an experimental method for acquiring densely sampled organ dose map for CT applications, based on optically stimulated luminescence (OSL) dosimeters “nanoDots” and standard ATOM anthropomorphic phantoms; and to provide the results of applying the method—a dose data set with good statistics for the comparison with Monte Carlo simulation result in the future. Methods: A standard ATOM phantom has densely located holes (in 3 × 3 cm or 1.5 × 1.5 cm grids), which are too small (5 mm in diameter) to host many types of dosimeters, including the nanoDots. The authors modified the conventional way in which nanoDots are used, by removing the OSL disks from the holders before inserting them inside a standard ATOM phantom for dose measurements. The authors solved three technical difficulties introduced by this modification: (1) energy dependent dose calibration for raw OSL readings; (2) influence of the brief background exposure of OSL disks to dimmed room light; (3) correct pairing between the dose readings and measurement locations. The authors acquired 100 dose measurements at various positions in the phantom, which was scanned using a clinical chest protocol with both angular and z-axis tube current modulations. Results: Dose calibration was performed according to the beam qualities inside the phantom as determined from an established Monte Carlo model of the scanner. The influence of the brief exposure to dimmed room light was evaluated and deemed negligible. Pairing between the OSL readings and measurement locations was ensured by the experimental design. The organ doses measured for a routine adult chest scan protocol ranged from 9.4 to 18.8 mGy, depending on the composition, location, and surrounding anatomy of the organs. The dose distribution across different slices of the phantom strongly depended on the z-axis mA modulation. In the same slice, doses to the soft tissues other than the spinal cord demonstrated relatively small variations, with the maximum COV around 11.4%. This might be attributed to the angular mA modulation, the placement of the dosimeters, the chest cavity of the scanned region, and the size of the phantom. Doses to the spinal cord were consistently lower than those to other soft tissues. Conclusions: The method is suited for acquiring densely sampled organ dose maps, and can be used for studying dose distributions relevant to subject size, organ location, and clinical CT protocols. PMID:23927332

  13. A method to acquire CT organ dose map using OSL dosimeters and ATOM anthropomorphic phantoms.

    PubMed

    Zhang, Da; Li, Xinhua; Gao, Yiming; Xu, X George; Liu, Bob

    2013-08-01

    To present the design and procedure of an experimental method for acquiring densely sampled organ dose map for CT applications, based on optically stimulated luminescence (OSL) dosimeters "nanoDots" and standard ATOM anthropomorphic phantoms; and to provide the results of applying the method--a dose data set with good statistics for the comparison with Monte Carlo simulation result in the future. A standard ATOM phantom has densely located holes (in 3×3 cm or 1.5×1.5 cm grids), which are too small (5 mm in diameter) to host many types of dosimeters, including the nanoDots. The authors modified the conventional way in which nanoDots are used, by removing the OSL disks from the holders before inserting them inside a standard ATOM phantom for dose measurements. The authors solved three technical difficulties introduced by this modification: (1) energy dependent dose calibration for raw OSL readings; (2) influence of the brief background exposure of OSL disks to dimmed room light; (3) correct pairing between the dose readings and measurement locations. The authors acquired 100 dose measurements at various positions in the phantom, which was scanned using a clinical chest protocol with both angular and z-axis tube current modulations. Dose calibration was performed according to the beam qualities inside the phantom as determined from an established Monte Carlo model of the scanner. The influence of the brief exposure to dimmed room light was evaluated and deemed negligible. Pairing between the OSL readings and measurement locations was ensured by the experimental design. The organ doses measured for a routine adult chest scan protocol ranged from 9.4 to 18.8 mGy, depending on the composition, location, and surrounding anatomy of the organs. The dose distribution across different slices of the phantom strongly depended on the z-axis mA modulation. In the same slice, doses to the soft tissues other than the spinal cord demonstrated relatively small variations, with the maximum COV around 11.4%. This might be attributed to the angular mA modulation, the placement of the dosimeters, the chest cavity of the scanned region, and the size of the phantom. Doses to the spinal cord were consistently lower than those to other soft tissues. The method is suited for acquiring densely sampled organ dose maps, and can be used for studying dose distributions relevant to subject size, organ location, and clinical CT protocols.

  14. A method to acquire CT organ dose map using OSL dosimeters and ATOM anthropomorphic phantoms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Da; Li, Xinhua; Liu, Bob

    Purpose: To present the design and procedure of an experimental method for acquiring densely sampled organ dose map for CT applications, based on optically stimulated luminescence (OSL) dosimeters “nanoDots” and standard ATOM anthropomorphic phantoms; and to provide the results of applying the method—a dose data set with good statistics for the comparison with Monte Carlo simulation result in the future.Methods: A standard ATOM phantom has densely located holes (in 3 × 3 cm or 1.5 × 1.5 cm grids), which are too small (5 mm in diameter) to host many types of dosimeters, including the nanoDots. The authors modified themore » conventional way in which nanoDots are used, by removing the OSL disks from the holders before inserting them inside a standard ATOM phantom for dose measurements. The authors solved three technical difficulties introduced by this modification: (1) energy dependent dose calibration for raw OSL readings; (2) influence of the brief background exposure of OSL disks to dimmed room light; (3) correct pairing between the dose readings and measurement locations. The authors acquired 100 dose measurements at various positions in the phantom, which was scanned using a clinical chest protocol with both angular and z-axis tube current modulations.Results: Dose calibration was performed according to the beam qualities inside the phantom as determined from an established Monte Carlo model of the scanner. The influence of the brief exposure to dimmed room light was evaluated and deemed negligible. Pairing between the OSL readings and measurement locations was ensured by the experimental design. The organ doses measured for a routine adult chest scan protocol ranged from 9.4 to 18.8 mGy, depending on the composition, location, and surrounding anatomy of the organs. The dose distribution across different slices of the phantom strongly depended on the z-axis mA modulation. In the same slice, doses to the soft tissues other than the spinal cord demonstrated relatively small variations, with the maximum COV around 11.4%. This might be attributed to the angular mA modulation, the placement of the dosimeters, the chest cavity of the scanned region, and the size of the phantom. Doses to the spinal cord were consistently lower than those to other soft tissues.Conclusions: The method is suited for acquiring densely sampled organ dose maps, and can be used for studying dose distributions relevant to subject size, organ location, and clinical CT protocols.« less

  15. Performance of optically stimulated luminescence Al₂O₃ dosimeter for low doses of diagnostic energy X-rays.

    PubMed

    Lim, Chang Seon; Lee, Sang Bock; Jin, Gye Hwan

    2011-10-01

    Personal dosimeters measure the radiation dose from exposure to hazardous sources outside the body. The present manuscript evaluates the performance of a commercially available optically stimulated luminescence (OSL) Al₂O₃ dosimeter using diagnostic energy X-rays. The OSL system satisfies the ANSI N13.11-2001 performance criteria for low dose diagnostic energy X-rays. Non-uniformity of sensitivity, dose linearity, X-ray energy response, and angular performance are all within the criteria of IEC-62387-1(2007). Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Force Limited Vibration Testing and Subsequent Redesign of the Naval Postgraduate School CubeSat Launcher

    DTIC Science & Technology

    2014-06-01

    release is controlled by a non-explosive actuator (NEA). Once the NEA is actuated, it releases the P-POD door, which springs open due to torsion ...deemed to be undesirable to OSL as it limited flexibility in final CubeSat position choices on NPSCuL. 24 Building on the lessons learned from the...OUTSat mission that included maintaining flexibility of CubeSat positions on NPSCuL, it was decided that the option to proto-qualify a CubeSat on the

  17. Structural Integrity of Water Reactor Pressure Boundary Components.

    DTIC Science & Technology

    1981-02-20

    environment, and load waveform parameters . A theory of the influence of dissolved oxygen content on the fatigue crack growth results in simulated PWR ...simulated PWR coolant is - (Continues ) DD IJN7 1473 EDITION OF I NOV S ..OSL- -C 2 S/ 0102-LF-014-6601 S1ECURITY CLASSI1FICATION OF THIS PAGE (When...not seem to influence the data, which was produced for a load ratio of 0.2 and a simulated PWR coolant environment. Test results for A106 Grade C piping

  18. The timing of sediment transport down Monterey Submarine Canyon, offshore California

    USGS Publications Warehouse

    Stevens, Thomas; Paull, Charles K.; Ussler, William III; McGann, Mary; Buylaert, Jan-Pieter; Lundsten, Eve M.

    2013-01-01

    While submarine canyons are the major conduits through which sediments are transported from the continents out into the deep sea, the time it takes for sediment to pass down through a submarine canyon system is poorly constrained. Here we report on the first study to couple optically stimulated luminescence (OSL) ages of quartz sand deposits and accelerator mass spectrometry 14C ages measured on benthic foraminifera to examine the timing of sediment transport through the axial channel of Monterey Submarine Canyon and Fan, offshore California. The OSL ages date the timing of sediment entry into the canyon head while the 14C ages of benthic foraminifera record the deposition of hemipelagic sediments that bound the sand horizons. We use both single-grain and small (∼2 mm area) single-aliquot regeneration approaches on vibracore samples from fining-upward sequences at various water depths to demonstrate relatively rapid, decadal-scale sand transport to at least 1.1 km depth and more variable decadal- to millennial-scale transport to a least 3.5 km depth on the fan. Significant differences between the time sand was last exposed at the canyon head (OSL age) and the timing of deposition of the sand (from 14C ages of benthic foraminifera in bracketing hemipelagic sediments) are interpreted as indicating that the sand does not pass through the entire canyon instantly in large individual events, but rather moves multiple times before emerging onto the fan. The increased spread in single-grain OSL dates with water depth provides evidence of mixing and temporary storage of sediment as it moves through the canyon system. The ages also indicate that the frequency of sediment transport events decreases with distance down the canyon channel system. The amalgamated sands near the canyon head yield OSL ages that are consistent with a sub-decadal recurrence frequency while the fining-upward sand sequences on the fan indicate that the channel is still experiencing events with a 150–250 year recurrence frequency out to 3.5 km water depths.    

  19. Luminescence profiling of loess-dominated archaeological layers of a Chalcolithic site, Northern Negev Desert fringe, Israel

    NASA Astrophysics Data System (ADS)

    López, Gloria I.; Roskin, Joel; Bee'ri, Ron

    2017-04-01

    This study applies a pulsed-photon Portable OSL Reader (PPSL) in investigating the palaeoenviroment and stages of development of a Chalcolithic site revealed during a salvage excavation. The (Shoqet Junction) site, within late Pleistocene loess-dominated sediment, is adjacent to the meandering and ephemeral Hebron Wadi in the Beer-Sheva Valley, at the fringe of the Northern Negev Desert (Israel). The site intermittently covers approximately 8 hectares and was exposed at 0.3 - 0.5 m depths beneath a plowed field. Five areas were excavated down to 4 meters. The site was dominated by an array of underground facilities: tunnels, (capped) shafts, walls, floors and infilled cavities were found within four main layers. The site includes a mixture of sediments: large amounts of organic material, weathered bricks, a powdery loess-like unit and thin Bk horizons. The artifact assemblage is associated with the Ghassulian culture. The objectives of this multi-parameter study, which combines PPSL luminescence profiling with sedimentological and geomorphic analyses, are to (1) analyze the Chalcolithic palaeoenvironments, aeolian and fluvial processes and location and morphology of streambeds, (2) identify possible deterministic physical influences upon the occupations (3) decipher the natural stratigraphic archive and discriminate between human and natural (aeolian/fluvial) induced sedimentation (4) create relative age profiles based on portable OSL measurements and OSL ages, in order to minimize OSL dating. Three main sections were profiled: a natural section - in order to identify the natural sedimentological regime and two walls of two excavation squares down to the sites' alluvial base. A small section above a prominent Bk horizon was also profiled. Altogether 58 samples were obtained for sediment and PPSL analyses. Luminescence profiles in general fit the stratigraphic breaks and enable discrimination between layers. Plowed and surface loess give low reads. Inverse reads along the profile are partly understood to be due to anthropogenic intervention with the sediment. The study highlights the potential and some of the complexities involved with portable OSL profiling of multi-layer prehistoric sites.

  20. SU-D-304-06: Measurement of LET in Patient-Specific Proton Therapy Treatment Fields Using Optically Stimulated Luminescence Detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Granville, DA; Sahoo, N; Sawakuchi, GO

    Purpose: To investigate the use of optically stimulated luminescence (OSL) detectors (OSLDs) for measurements of dose-averaged linear energy transfer (LET) in patient-specific proton therapy treatment fields. Methods: We used Al{sub 2}O{sub 3}:C OSLDs made from the same material as commercially available nanoDot OSLDs from Landauer, Inc. We calibrated two parameters of the OSL signal as functions of LET in therapeutic proton beams: the ratio of the ultraviolet and blue emission intensities (UV/blue ratio) and the OSL curve shape. These calibration curves were created by irradiating OSLDs in passively scattered beams of known LET (0.96 to 3.91 keV/µm). The LET valuesmore » were determined using a validated Monte Carlo model of the beamline. We then irradiated new OSLDs with the prescription dose (16 to 74 cGy absorbed dose to water) at the center of the spread-out Bragg peak (SOBP) of four patient-specific treatment fields. From readouts of these OSLDs, we determined both the UV/blue ratio and OSL curve shape parameters. Combining these parameters with the calibration curves, we were able to measure LET using the OSLDs. The measurements were compared to the theoretical LET values obtained from Monte Carlo simulations of the patient-specific treatments fields. Results: Using the UV/blue ratio parameter, we were able to measure LET within 3.8%, 6.2%, 5.6% and 8.6% of the Monte Carlo value for each of the patient fields. Similarly, using the OSL curve shape parameter, LET measurements agreed within 0.5%, 11.0%, 2.5% and 7.6% for each of the four fields. Conclusion: We have demonstrated a method to verify LET in patient-specific proton therapy treatment fields using OSLDs. The possibility of enhancing biological effectiveness of proton therapy treatment plans by including LET in the optimization has been previously shown. The LET verification method we have demonstrated will be useful in the quality assurance of such LET optimized treatment plans. DA Granville received financial support from the Natural Sciences and Engineering Research Council of Canada.« less

  1. A methodology for on‐board CBCT imaging dose using optically stimulated luminescence detectors

    PubMed Central

    Yusuf, Muhammad; Alothmany, Nazeeh; Kinsara, A. Abdulrahman; Abdulkhaliq, Fahad; Ghamdi, Suliman M.; Saoudi, Abdelhamid

    2016-01-01

    Cone‐beam computed tomography CBCT systems are used in radiation therapy for patient alignment and positioning. The CBCT imaging procedure for patient setup adds substantial radiation dose to patient's normal tissue. This study presents a complete procedure for the CBCT dosimetry using the InLight optically‐stimulated‐luminescence (OSL) nanoDots. We report five dose parameters: the mean slice dose (DMSD); the cone beam dose index (CBDIW); the mean volume dose (DMVD); point‐dose profile, D(FOV); and the off‐field Dose. In addition, CBCT skin doses for seven pelvic tumor patients are reported. CBCT‐dose measurement was performed on a custom‐made cylindrical acrylic body phantom (50 cm length, 32 cm diameter). We machined 25 circular disks (2 cm thick) with grooves and holes to hold OSL‐nanoDots. OSLs that showed similar sensitivities were selected and calibrated against a Farmer‐type ionization‐chamber (0.6 CT) before being inserted into the grooves and holes. For the phantom scan, a standard CBCT‐imaging protocol (pelvic sites: 125 kVp, 80 mA and 25 ms) was used. Five dose parameters were quantified: DMSD, CBDIW, DMVD, D(FOV), and the off‐field dose. The DMSD for the central slice was 31.1±0.85 mGy, and CBDIW was 34.5±0.6 mGy at 16 cm FOV. The DMVD was 25.6±1.1 mGy. The off‐field dose was 10.5 mGy. For patients, the anterior and lateral skin doses attributable to CBCT imaging were 39.04±4.4 and 27.1±1.3 mGy, respectively. OSL nanoDots were convenient to use in measuring CBCT dose. The method of selecting the nanoDots greatly reduced uncertainty in the OSL measurements. Our detailed calibration procedure and CBCT dose measurements and calculations could prove useful in developing OSL routines for CBCT quality assessment, which in turn gives them the property of high spatial resolution, meaning that they have the potential for measurement of dose in regions of severe dose‐gradients. PACS number(s): 87.57.‐s, 87.57.Q, 87.57.uq PMID:27685143

  2. Effects of nanostructuring on luminescence properties of SrS:Ce,Sm phosphor: An experimental and phenomenological study

    NASA Astrophysics Data System (ADS)

    Yazdanmehr, Mohsen; Sadeghi, Hossein; Tehrani, Masoud Kavosh; Hashemifar, Seyed Javad; Mahdavi, Mohammad

    2018-01-01

    In this work, we employ various experimental techniques to illustrate the effects of nanostructuring on improvement of the luminescence properties of the polycrystalline SrS co-activated by cerium and samarium dopants (SrS : Ce , Sm). The nano and microstructure SrS : Ce , Sm powders were synthesized by the co-precipitation and solid state diffusion methods, respectively, followed by the spark plasma sintering (SPS) process to densify powders into pellet shape. It is observed that the photo-luminescence (PL), radio-luminescence (RL), and optically stimulated luminescence (OSL) emission intensity of the nanostructure samples are significantly improved with respect to the microstructure samples. Moreover, by using an accurate photomultiplier tube, we measured the CW-OSL decay curves of the samples to demonstrate much higher and faster sensitivity of the nanostructure SrS : Ce , Sm for in-flight and online OSL radiation dosimetry. The obtained absorption and emission spectra are used for phenomenology of the electronic band structure of the SrS : Ce , Sm micro and nano-phosphors inside the band gap. The proposed phenomenological electronic structures are then used to clarify the role of Ce3+ and Sm3+ localized energy levels in the luminescence properties of the nano and microstructure samples. It is argued that electronic transitions from the 2T2g state of Ce3+ and the 4G5/2 state of Sm3+ have strong contribution to the PL and RL emission spectra, while in the OSL mechanism, the Sm3+ 4G5/2 state is mainly responsible for electrons trapping.

  3. Energy dependence measurement of small-type optically stimulated luminescence (OSL) dosimeter by means of characteristic X-rays induced with general diagnostic X-ray equipment.

    PubMed

    Takegami, Kazuki; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi; Maehata, Itsumi; Kanazawa, Yuki; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo

    2016-01-01

    For X-ray inspections by way of general X-ray equipment, it is important to measure an entrance-skin dose. Recently, a small optically stimulated luminescence (OSL) dosimeter was made commercially available by Landauer, Inc. The dosimeter does not interfere with the medical images; therefore, it is expected to be a convenient detector for measuring personal exposure doses. In an actual clinical situation, it is assumed that X-rays of different energies will be detected by a dosimeter. For evaluation of the exposure dose measured by a dosimeter, it is necessary to know the energy dependence of the dosimeter. Our aim in this study was to measure the energy dependence of the OSL dosimeter experimentally in the diagnostic X-ray region. Metal samples weighing several grams were irradiated and, in this way, characteristic X-rays having energies ranging from 8 to 85 keV were generated. Using these mono-energetic X-rays, the dosimeter was irradiated. Simultaneously, the fluence of the X-rays was determined with a CdTe detector. The energy-dependent efficiency of the dosimeter was derived from the measured value of the dosimeter and the fluence. Moreover, the energy-dependent efficiency was calculated by Monte-Carlo simulation. The efficiency obtained in the experiment was in good agreement with that of the simulation. In conclusion, our proposed method, in which characteristic X-rays are used, is valuable for measurement of the energy dependence of a small OSL dosimeter in the diagnostic X-ray region.

  4. Luminescence of quartz and feldspar fingerprints provenance and correlates with the source area denudation in the Amazon River basin

    NASA Astrophysics Data System (ADS)

    Sawakuchi, A. O.; Jain, M.; Mineli, T. D.; Nogueira, L.; Bertassoli, D. J.; Häggi, C.; Sawakuchi, H. O.; Pupim, F. N.; Grohmann, C. H.; Chiessi, C. M.; Zabel, M.; Mulitza, S.; Mazoca, C. E. M.; Cunha, D. F.

    2018-06-01

    The Amazon region hosts the world's largest watershed spanning from high elevation Andean terrains to lowland cratonic shield areas in tropical South America. This study explores variations in optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL) signals in suspended silt and riverbed sands retrieved from major Amazon rivers. These rivers drain Pre-Cambrian to Cenozoic source rocks in areas with contrasting denudation rates. In contrast to the previous studies, we do not observe an increase in the OSL sensitivity of quartz with transport distance; for example, Tapajós and Xingu Rivers show more sensitive quartz than Solimões and Madeira Rivers, even though the latter have a significantly larger catchment area and longer sediment transport distance. Interestingly, high sensitivity quartz is observed in rivers draining relatively stable Central Brazil and Guiana shield areas (denudation rate ξ = 0.04 mmyr-1), while low sensitivity quartz occurs in less stable Andean terrains (ξ = 0.24 mmyr-1). An apparent linear correlation between quartz OSL sensitivity and denudation rate suggests that OSL sensitivity may be used as a proxy for erosion rates in the Amazon basin. Furthermore, luminescence sensitivity measured in sand or silt arises from the same mineral components (quartz and feldspar) and clearly discriminates between Andean and shield sediments, avoiding the grain size bias in provenance analysis. These results have implications for using luminescence sensitivity as a proxy for Andean and shield contributions in the stratigraphic record, providing a new tool to reconstruct past drainage configurations within the Amazon basin.

  5. Photon energy dependence of three fortuitous dosemeters from personal electronic devices, measured by optically stimulated luminescence.

    PubMed

    Beerten, Koen; Vanhavere, Filip

    2010-08-01

    New data are presented with regard to the relative OSL sensitivity of three different emergency dosemeters irradiated to various photon energies approximately between 48 and 1250 keV using blue excitation light. Investigated components extracted from commonly worn objects include those from USB flash drives (alumina substrate), mobile phones (Ba-rich silicate) and credit cards (chip card module). Several basic properties have been investigated such as the overall radiation sensitivity, the shape of the decay curve and fading of the OSL signal. An increase of the sensitivity for low energies relative to (60)Co gamma rays can be observed for the three dosemeters, the increase being very pronounced for the Ba-rich component (factor of 10) and less pronounced for the chip card module (factor of 2). It is concluded that proper dose correction factors for photon energy have to be applied in order to accurately determine the absorbed dose to tissue. The OSL sensitivity to neutron irradiation was investigated as well, but this was found to be less than the gamma sensitivity.

  6. Sol-gel derived copper-doped silica glass as a sensitive material for X-ray beam dosimetry

    NASA Astrophysics Data System (ADS)

    Capoen, Bruno; Hamzaoui, Hicham El; Bouazaoui, Mohamed; Ouerdane, Youcef; Boukenter, Aziz; Girard, Sylvain; Marcandella, Claude; Duhamel, Olivier

    2016-01-01

    The light emission from a sol-gel-derived Cu-doped silica glass was studied under 10 keV X-ray irradiation using a fibered setup. Both radioluminescence (RL) and optically stimulated luminescence (OSL) were analyzed at different high dose rates up to 50 Gy/s and for different exposure times, yielding accumulated doses up to 50 kGy (in SiO2). Even if a darkening effect appears at this dose level, the material remains X-sensitive after exposure to several kGy. At low dose rate, the scintillation mechanisms are similar to photoluminescence, involving the Cu+ ions electronic levels, contrary to the nonlinear domain (for dose rates higher than 30 Gy/s). This RL, as well as the OSL, could be exploited in their linear domain to measure doses as high as 3 kGy. A thorough study of the OSL signal has shown that it must be employed with caution in order to take the fading phenomenon and the response dependency on stimulation source intensity into consideration.

  7. Energy absorption buildup factors, exposure buildup factors and Kerma for optically stimulated luminescence materials and their tissue equivalence for radiation dosimetry

    NASA Astrophysics Data System (ADS)

    Singh, Vishwanath P.; Badiger, N. M.

    2014-11-01

    Optically stimulated luminescence (OSL) materials are sensitive dosimetric materials used for precise and accurate dose measurement for low-energy ionizing radiation. Low dose measurement capability with improved sensitivity makes these dosimeters very useful for diagnostic imaging, personnel monitoring and environmental radiation dosimetry. Gamma ray energy absorption buildup factors and exposure build factors were computed for OSL materials using the five-parameter Geometric Progression (G-P) fitting method in the energy range 0.015-15 MeV for penetration depths up to 40 mean free path. The computed energy absorption buildup factor and exposure buildup factor values were studied as a function of penetration depth and incident photon energy. Effective atomic numbers and Kerma relative to air of the selected OSL materials and tissue equivalence were computed and compared with that of water, PMMA and ICRU standard tissues. The buildup factors and kerma relative to air were found dependent upon effective atomic numbers. Buildup factors determined in the present work should be useful in radiation dosimetry, medical diagnostics and therapy, space dosimetry, accident dosimetry and personnel monitoring.

  8. New Quaternary geochronometric constraints on river incision in the Virginia Piedmont: Relative contributions of climate, base-level fall, knickpoint retreat, and active tectonics

    NASA Astrophysics Data System (ADS)

    Malenda, Helen Fitzgerald

    River terraces are fluvial landforms that represent flood plains abandoned through river incision and, when accurately correlated and dated, can serve as paleogeodetic markers, indicating the elevation and location of past channels and the subsequent fluvial and tectonic processes shaping the landscape. Fluvial terraces are most useful when the incision processes that caused their abandonment and formation are better understood. This thesis studies river incision reconstructed from fluvial terraces of the South Anna River in the central Virginia Piedmont, USA. The South Anna River flows directly above an active fault, on which large, but infrequent seismic events have occurred, and the most recent event was the 23 August 2011 Mineral earthquake. Two conceptual incision models are tested to better understand the fluvial response to active tectonics in this region: 1) spatially-uniform vertical incision and 2) diachronous horizontal knickpoint retreat. Here, terraces and incision were evaluated in the context of a 1:24,000 scale surficial map of alluvial deposits, optically stimulated luminescence (OSL) and infrared luminescence (IRSL) geochronology, and knickpoint celerity modeling. The South Anna River and its tributaries traverse across the geologic, topographic and structural grain of central Virginia Piedmont, USA, a region known for Late Cenozoic base-level fall, high amplitude climate changes, and historic seismicity. Litho- and pedostratigraphically correlative deposits are found to form five groups of terraces (Qt1-Qt5) with similar, but not exact relative elevations above modern channel. Within these groups, the terraces have similar OSL/IRSL ages that do not systematically decrease in age upstream towards knickpoint in the modern channel. Similarly, the modeled rate of knickpoint retreat through the South Anna channel of ~7-14km/Ma is too slow to explain the time-transgressive OSL/IRSL dates for any terrace group. Terrace formation by knickpoint migration and horizontal floodplain abandonment is rejected as a dominant process in terrace formation, in favor of more spatially-uniform vertical incision. In this landscape, the OSL/IRSL results suggest that flood plains are widened and then are abandoned and become terraces as the South Anna channel responds to climatically-driven unsteady changes in discharge and sediment yield. The complex age-elevation relationships of terraces proximal to epicenter of the 23 August 2011 Mineral earthquake argue for a terrace correlation that allows for rock uplift consistent with the co-seismic response of the 2011 Mineral earthquake.

  9. Luminescence signal profiling: a new proxy for sedimentologically "invisible" marine Mass Transport Deposits (MTDs)

    NASA Astrophysics Data System (ADS)

    López, Gloria I.; Bialik, Or; Waldmann, Nicolas

    2017-04-01

    When dealing with fine-grained, organic-rich, colour-monotone, underwater marine sediment cores retrieved from the continental shelf or slope, the initial visual impression, upon split-opening the vessels, is often of a "disappointing" homogeneous, monotonous, continuous archive. Only after thorough, micro- to macro-scale, multi-parameter investigations the sediment reveals its treasures, initially by performing some measurements on the intact core itself, hence depicting for the first time its contents, and subsequently by carrying out the destructive, multi-proxy sample-based analyses. Usually, routine Multi-Sensor Core Logger (MSCL) measurements of petrophysical parameters (e.g. magnetic susceptibility, density, P-Wave velocity) on un-split sediment cores are the first undertaken while still on-board in the field or back at the laboratory. Less often done, but equally valuable, are continuous X-Ray and CT scan imaging of the same intact archives. Upon splitting, routine granulometry, micro- and macro-fossil and invertebrate identification, total organic / inorganic carbon content (TOC / TIC), amid other analyses take place. The geochronology component is also established usually by AMS 14C on selected organic-rich units, and less common is Optically Stimulated Luminescence (OSL) dating used on the coarser-grained, siliciclastic layers. A relatively new tool used in Luminescence, the Portable OSL Reader, employed to rapidly assess the luminescence signal of untreated poly-mineral samples to assist with targeted field sampling for full OSL dating, was used for the first time in marine sediment cores as a novel petrophysical characterization tool with astonishing results. In this study, two 2 m-long underwater piston sediment cores recovered from 200 m depths on the continental shelf off-southern Israel, were subjected to pulsed-photon stimulation (PPSL) obtaining favourable luminescence signals along their entire lengths. Astoundingly, luminescence signals were obtained on both, already split-opened cores. Both cores depicted the monotonous characteristics of homogeneousness down-core as per most of the results obtained from the non-destructive and destructive tests. One of the cores showed several small higher energy events, including a Mass Transport Deposit (MTD) within its first 10 cm, only fully visible on the CT scan imaging, the PPSL profile and particle size distribution plot. This initial investigation demonstrates the feasibility and usefulness of luminescence profiling as a new sedimentological and petrophysical proxy to better visualize homogeneous yet complex, fine-grained, underwater archives. Moreover, it helps to understand the continuity of the stratigraphy and linearity of deposition of the sediment, besides assisting on the estimation of relative ages provided that good OSL ages are obtained throughout the recovered archive.

  10. Ages, durations and behavioural implications of Middle Stone Age industries in southern Africa: advances in optical dating of individual grains of quartz

    NASA Astrophysics Data System (ADS)

    Jacobs, Z.

    2009-04-01

    Recent developments in OSL dating have focussed on the measurement of individual sand-sized grains of quartz. Single-grain dating allows the identification of contaminant grains in a sample and their exclusion before final age determination, and the ability to directly check the stratigraphic integrity of archaeological sequences and address concerns about post-deposition sediment mixing. These benefits result in single-grain OSL ages being both accurate and precise. Even greater precision can be attained by adopting a systematic approach to the collection and analysis of OSL data. This involves one operator using the same OSL stimulation and detection instrument, laboratory radiation sources, calibration standards, and analytical procedures for all samples. By holding these experimental parameters constant, sources of error common to all samples are removed, enabling far greater resolution of the true age structure. This approach was recently used to determine the timing and duration of two bursts of Middle Stone Age technological and behavioural innovation - the Still Bay (SB) and Howieson's Poort (HP) - in southern Africa. These distinctive artefacts are associated with the first evidence for symbols and personal ornaments, and may have been the catalyst for the expansion of Homo sapiens populations in Africa 80,000-60,000 years ago and for the subsequent migration of modern humans out of Africa. Testing such hypotheses, and the putative role of climate change, has been hampered by poor age constraints for the HP and SB industries. Previous attempts to resolve the start and end dates of these industries had been largely obscured by the chronological' haze' arising from a variety of different materials being dated by different methods using different equipment, calibration standards, measurement procedures and techniques of data analysis. By clearing this haze and placing all ages on a common timescale, we were able to constrain the timing of the SB and HP, and the gap between them, to better than 3000 years at the 95% confidence interval. Both industries occur within the interval of population expansions in Africa inferred from genetic studies. A meta-analysis shows that our new ages are consistent with previous estimates but are more precise, revealing a lack of spatial patterning of the HP and SB across varied climatic and ecological zones. We find a temporal coincidence with major swings in climate, but not uniquely with these industries. Environmental factors may, therefore, have been responsible for episodic occupation of rock shelters, but were not the forcing mechanism behind the emergence of modern human behaviour.

  11. TL-OSL study of Li{sub 3}PO{sub 4}: Mg, Cu phosphor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rahangdale, S. R., E-mail: sachin.rahangdale1@gmail.com; Wankhede, S. P.; Dhabekar, B. S.

    In the present work, we report the thermoluminescence and optically stimulated luminescence properties of Mg and Cu doped Li{sub 3}PO{sub 4} phosphor. The phosphor was synthesized by precipitation method. The thermoluminescence dosimetric peak temperature for the phosphor varies with concentrations of Mg and Cu. Li{sub 3}PO{sub 4} shows good response to 470nm optical stimulation. The OSL sensitivity of the phosphor is approximately 12 times than that of standard Lithium magnesium phosphate. This study may help to develop this material for the application in real time dosimetry using optically stimulated luminescence.

  12. Measurement of the distribution of radiation in the area surrounding the target mass using optically stimulated luminescence technique.

    PubMed

    Tanır, A Güneş; Yedek, Hatice; Koç, Kemal; Bölükdemir, M Hicabi

    2017-01-01

    The scattered doses received by the area surrounding the target that has been subjected to x-rays were investigated. Two experiments were carried out: 1- Al 2 O 3 : C was used as dosimeter and the luminescence counts was measured using both the RisØ TL/OSL system and an ion chamber. 2- BeO aliquots were used and the counts were read using the IBEOX/OSL system. According to the results, the doses absorbed by the area surrounding the target are significantly amount. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. TL-OSL study of Li3PO4: Mg, Cu phosphor

    NASA Astrophysics Data System (ADS)

    Rahangdale, S. R.; Wankhede, S. P.; Dhabekar, B. S.; Palikundwar, U. A.; Moharil, S. V.

    2015-08-01

    In the present work, we report the thermoluminescence and optically stimulated luminescence properties of Mg and Cu doped Li3PO4 phosphor. The phosphor was synthesized by precipitation method. The thermoluminescence dosimetric peak temperature for the phosphor varies with concentrations of Mg and Cu. Li3PO4 shows good response to 470nm optical stimulation. The OSL sensitivity of the phosphor is approximately 12 times than that of standard Lithium magnesium phosphate. This study may help to develop this material for the application in real time dosimetry using optically stimulated luminescence.

  14. Time-Transgressive Nature of the Magnetic Susceptibility Record across the Chinese Loess Plateau at the Pleistocene/Holocene Transition.

    PubMed

    Dong, Yajie; Wu, Naiqin; Li, Fengjiang; Huang, Linpei; Wen, Wenwen

    2015-01-01

    The loess stratigraphic boundary at the Pleistocene/Holocene transition defined by the magnetic susceptibility (MS) has previously been assumed to be synchronous with the Marine Isotope Stage (MIS) 2/1 boundary, and approximately time-synchronous at different sections across the Chinese Loess Plateau (CLP). However, although this assumption has been used as a basis for proxy-age model of Chinese loess deposits, it has rarely been tested by using absolute dating methods. In this study, we applied a single-aliquot regenerative-dose (SAR) protocol to the 45-63 μm quartz grain-size fraction to derive luminescence ages for the last glacial and Holocene sections of three loess sections on a transect from southeast to northwest across the CLP. Based on the 33 closely spaced optically stimulated luminescence (OSL) samples from the three sections, OSL chronologies were established using a polynomial curve fit at each section. Based on the OSL chronology, the timing of the Pleistocene/Holocene boundary, as defined by rapid changes in MS values, is dated at ~10.5 ka, 8.5 ka and 7.5 ka in the Yaoxian section, Jingchuan and Huanxian sections respectively. These results are clearly inconsistent with the MIS 2/1 boundary age of 12.05 ka, and therefore we conclude that the automatic correlation of the Pleistocene/Holocene transition, as inferred from the MS record, with the MIS 2/1 boundary is incorrect. The results clearly demonstrate that the marked changes in MS along the southeast to northwest transect are time-transgressive among the different sites, with the timing of significant paleosol development as indicated by the MS record being delayed by 3-4 ka in the northwest compared to the southeast. Our results suggest that this asynchronous paleosol development during the last deglacial was caused by the delayed arrival of the summer monsoon in the northwest CLP compared to the southeast.

  15. Time-Transgressive Nature of the Magnetic Susceptibility Record across the Chinese Loess Plateau at the Pleistocene/Holocene Transition

    PubMed Central

    Dong, Yajie; Wu, Naiqin; Li, Fengjiang; Huang, Linpei; Wen, Wenwen

    2015-01-01

    The loess stratigraphic boundary at the Pleistocene/Holocene transition defined by the magnetic susceptibility (MS) has previously been assumed to be synchronous with the Marine Isotope Stage (MIS) 2/1 boundary, and approximately time-synchronous at different sections across the Chinese Loess Plateau (CLP). However, although this assumption has been used as a basis for proxy-age model of Chinese loess deposits, it has rarely been tested by using absolute dating methods. In this study, we applied a single-aliquot regenerative-dose (SAR) protocol to the 45–63 μm quartz grain-size fraction to derive luminescence ages for the last glacial and Holocene sections of three loess sections on a transect from southeast to northwest across the CLP. Based on the 33 closely spaced optically stimulated luminescence (OSL) samples from the three sections, OSL chronologies were established using a polynomial curve fit at each section. Based on the OSL chronology, the timing of the Pleistocene/Holocene boundary, as defined by rapid changes in MS values, is dated at ~10.5 ka, 8.5 ka and 7.5 ka in the Yaoxian section, Jingchuan and Huanxian sections respectively. These results are clearly inconsistent with the MIS 2/1 boundary age of 12.05 ka, and therefore we conclude that the automatic correlation of the Pleistocene/Holocene transition, as inferred from the MS record, with the MIS 2/1 boundary is incorrect. The results clearly demonstrate that the marked changes in MS along the southeast to northwest transect are time-transgressive among the different sites, with the timing of significant paleosol development as indicated by the MS record being delayed by 3–4 ka in the northwest compared to the southeast. Our results suggest that this asynchronous paleosol development during the last deglacial was caused by the delayed arrival of the summer monsoon in the northwest CLP compared to the southeast. PMID:26186443

  16. Fiber-Coupled, Time-Gated { {Al}}_{2}{ {O}}_{3} : { {C}} Radioluminescence Dosimetry Technique and Algorithm for Radiation Therapy With LINACs

    NASA Astrophysics Data System (ADS)

    Magne, Sylvain; Deloule, Sybelle; Ostrowsky, Aimé; Ferdinand, Pierre

    2013-08-01

    An original algorithm for real-time In Vivo Dosimetry (IVD) based on Radioluminescence (RL) of dosimetric-grade Al2O3:C crystals is described and demonstrated in reference conditions with 12-MV photon beams from a Saturne 43 linear accelerator (LINAC), simulating External Beam Radiation Therapy (EBRT) treatments. During the course of irradiation, a portion of electrons is trapped within the Al2O3:C crystal while another portion recombines and generates RL, recorded on-line using an optical fiber. The RL sensitivity is dose-dependent and increases in accordance with the concentration of trapped electrons. Once irradiation is completed, the Al2O3:C crystal is reset by laser light (reusable) and the resultant OSL (Optically Stimulated Luminescence) is also collected back by the remote RL-OSL reader and finally integrated to yield the absorbed dose. During irradiation, scintillation and Cerenkov lights generated within the optical fiber (“stem effect”) are removed by a time-discrimination method involving a discriminating unit and a fiber-coupled BGO scintillator placed in the irradiation room, next to the LINAC. The RL signals were then calibrated with respect to reference dose and dose rate data using an ionization chamber (IC). The algorithm relies upon the integral of the RL and provides the accumulated dose (useful to the medical physicist) at any time during irradiation, the dose rate being derived afterwards. It is tested with both step and arbitrary dose rate profiles, manually operated from the LINAC control desk. The doses measured by RL and OSL are both compared to reference doses and deviations are about ±2% and ±1% respectively, thus demonstrating the reliability of the algorithm for arbitrary profiles and wide range of dose rates. Although the calculation was done off-line, it is amenable to real-time processing during irradiation.

  17. OSL and pollen concentrate 14C dating of dammed lake sediments at Maoxian, east Tibet, and implications for two historical earthquakes in AD 638 and 952

    NASA Astrophysics Data System (ADS)

    Xu, H.; Jiang, H.; Yu, S.; Yang, H.; Chen, J.

    2016-12-01

    Formation of dammed lakes provides exceptionally important information of continental geological processes, responding to tectonic and climatic influences. Establishing accurate geochronological frameworks within lake strata is challenging because the stratigraphy is often bereft of biostratigraphy and directly dateable material. Optically Stimulated Luminescence (OSL) and AMS 14C dating of pollen concentrates are well-established tools for dating lake sediments. Whether they are suitable for lake sediments in high-alpine settings remains uncertain. In this study, OSL and AMS 14C dating of pollen concentrate were conducted on the Diaolin section in a high-alpine setting in the eastern Tibetan Plateau. Good match of both dating results suggests that they are fit for dating lake sediments in high alpine settings. More than 300 g of sediment is required for preparation of pollen concentrates. During the pretreatment, 3% NaOH solution should be added to the sample, and then heated until just boiling ( 5 min) because NaOH treatment easily destroys pollen grains. Applying the heavy liquid flotation with specific gravity of 1.74-1.76 is useful to isolate relatively pure pollen grains. Sieving with a 20-μm and 63-μm mesh can concentrate pollen grains substantially. The OSL and AMS 14C dating yielded the basal age of the Diaolin section (650 AD). This indicates that the dammed-lake formed around 650 AD, probably caused by the earthquake occurring in the study area in 638 AD. The seismites characterized by soft-sediment deformation and phyllite layer happened at 780-980 AD, probably corresponding to the earthquake occurring on November 20, 952 AD in the study area.

  18. Evaluation of Al2O3:C optically stimulated luminescence (OSL) dosimeters for passive dosimetry of high-energy photon and electron beams in radiotherapy.

    PubMed

    Yukihara, E G; Mardirossian, G; Mirzasadeghi, M; Guduru, S; Ahmad, S

    2008-01-01

    This article investigates the performance of Al2O3: C optically stimulated luminescence dosimeters (OSLDs) for application in radiotherapy. Central-axis depth dose curves and optically stimulated luminescence (OSL) responses were obtained in a water phantom for 6 and 18 MV photons, and for 6, 9, 12, 16, and 20 MeV electron beams from a Varian 21EX linear accelerator. Single OSL measurements could be repeated with a precision of 0.7% (one standard deviation) and the differences between absorbed doses measured with OSLDs and an ionization chamber were within +/- 1% for photon beams. Similar results were obtained for electron beams in the low-gradient region after correction for a 1.9% photon-to-electron bias. The distance-to-agreement values were of the order of 0.5-1.0 mm for electrons in high dose gradient regions. Additional investigations also demonstrated that the OSL response dependence on dose rate, field size, and irradiation temperature is less than 1% in the conditions of the present study. Regarding the beam energy/quality dependence, the relative response of the OSLD for 18 MV was (0.51 +/- 0.48)% of the response for the 6 MV photon beam. The OSLD response for the electron beams relative to the 6 MV photon beam. The OSLD response for the electron beams relative to the 6 MV photon beam was in average 1.9% higher, but this result requires further confirmation. The relative response did not seem to vary with electron energy at dmax within the experimental uncertainties (0.5% in average) and, therefore, a fixed correction factor of 1.9% eliminated the energy dependence in our experimental conditions.

  19. Evaluation of Al{sub 2}O{sub 3}:C optically stimulated luminescence (OSL) dosimeters for passive dosimetry of high-energy photon and electron beams in radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yukihara, E. G.; Mardirossian, G.; Mirzasadeghi, M.

    This article investigates the performance of Al{sub 2}O{sub 3}:C optically stimulated luminescence dosimeters (OSLDs) for application in radiotherapy. Central-axis depth dose curves and optically stimulated luminescence (OSL) responses were obtained in a water phantom for 6 and 18 MV photons, and for 6, 9, 12, 16, and 20 MeV electron beams from a Varian 21EX linear accelerator. Single OSL measurements could be repeated with a precision of 0.7% (one standard deviation) and the differences between absorbed doses measured with OSLDs and an ionization chamber were within {+-}1% for photon beams. Similar results were obtained for electron beams in the low-gradientmore » region after correction for a 1.9% photon-to-electron bias. The distance-to-agreement values were of the order of 0.5-1.0 mm for electrons in high dose gradient regions. Additional investigations also demonstrated that the OSL response dependence on dose rate, field size, and irradiation temperature is less than 1% in the conditions of the present study. Regarding the beam energy/quality dependence, the relative response of the OSLD for 18 MV was (0.51{+-}0.48)% of the response for the 6 MV photon beam. The OSLD response for the electron beams relative to the 6 MV photon beam. The OSLD response for the electron beams relative to the 6 MV photon beam was in average 1.9% higher, but this result requires further confirmation. The relative response did not seem to vary with electron energy at d{sub max} within the experimental uncertainties (0.5% in average) and, therefore, a fixed correction factor of 1.9% eliminated the energy dependence in our experimental conditions.« less

  20. Geochronological (OSL) and geomorphological investigations at the presumed Frankfurt ice marginal position in northeast Germany

    NASA Astrophysics Data System (ADS)

    Hardt, Jacob; Lüthgens, Christopher; Hebenstreit, Robert; Böse, Margot

    2016-12-01

    The Weichselian Frankfurt ice marginal position in northeast Germany has been critically discussed in the past owing to weak morphological evidence and a lack of clear sedimentological records. This study aims to contribute to this discussion with new geochronological and geomorphological results. Apart from very few cosmogenic exposure ages, the time frame is to date still based on long distance correlation with radiocarbon chronologies. We selected a study site in a key position regarding the classic location of the Frankfurt ice marginal position and the recently described arcuate ridge structures on the Barnim plateau. For the first time we present Optically Stimulated Luminescence (OSL) ages of quartz from glaciofluvial deposits for this Weichselian phase. Our results indicate an advance of the Scandinavian Ice Sheet (SIS) at around 34.1 ± 4.6 ka. This is in agreement with OSL ages from sandur deposits at the Brandenburg ice marginal position located farther south and could also be correlated with the Klintholm advance in Denmark. The subsequent meltdown phase lasted until around 26.3 ± 3.7 ka. During the meltdown phase a minor oscillation of the SIS caused the formation of the recently described arcuate ridges on the Barnim till plain. Recalculated surface exposure ages of glacigenic boulders with an updated global production rate indicate a landscape stabilization phase at around 22.7 ± 1.6 ka, which is in agreement with our ages. A phase of strong aeolian activity has been dated with OSL to 1 ± 0.1 ka; this may have been triggered by human activities that are documented in this region for the medieval period.

  1. Navy Occupational Health Information Management System (NOHIMS). System/Functional Manager’s Guide

    DTIC Science & Technology

    1987-04-01

    6g1111018 U0sl0 ETtlt FILE SVIIVT TEST 344 ISN P ?I So DUPLICATE %ON 9NI IULIPLE EaTsIf r Vi0 SIC saa4iSl reft" @4r AirM UNITPL l l~~ ( Of MIN INVAID OSl ...I . . ... I I I . . Noise Source: A-5 . I ! I I I .! I .,I ! . 1 I Calibration Information: Dosimeter Pre Calibration...department to identify their records uniquely in the Materials Management System. DoD - Department of Defense. Dosimeter - A device for measuring

  2. Properties of lithium aluminate for application as an OSL dosimeter

    NASA Astrophysics Data System (ADS)

    Twardak, A.; Bilski, P.; Marczewska, B.; Lee, J. I.; Kim, J. L.; Gieszczyk, W.; Mrozik, A.; Sądel, M.; Wróbel, D.

    2014-11-01

    Several samples of undoped and carbon or copper doped lithium aluminate (LiAlO2) were prepared in an attempt to achieve a material, which can be applicable in optically stimulated luminescence (OSL) dosimetry. All investigated samples are highly sensitive to ionizing radiation and show good reproducibility. The undoped and copper doped samples exhibit sensitivity several times higher than that of Al2O3:C, while sensitivity of the carbon doped samples is lower. The studied samples exhibit significant fading, but dynamics of signal loss is different for differently doped samples, what indicates a possibility of improving this characteristic by optimizing dopant composition.

  3. Thermally and optically stimulated radiative processes in Eu and Y co-doped LiCaAlF6 crystal

    NASA Astrophysics Data System (ADS)

    Fukuda, Kentaro; Yanagida, Takayuki; Fujimoto, Yutaka

    2015-06-01

    Yttrium co-doping was attempted to enhance dosimeter performance of Eu doped LiCaAlF6 crystal. Eu doped and Eu, Y co-doped LiCaAlF6 were prepared by the micro-pulling-down technique, and their dosimeter characteristics such as optically stimulated luminescence (OSL) and thermally stimulated luminescence (TSL) were investigated. By yttrium co-doping, emission intensities of OSL and TSL were enhanced by some orders of magnitude. In contrast, scintillation characteristics of yttrium co-doped crystal such as intensity of prompt luminescence induced by X-ray and light yield under neutron irradiation were degraded.

  4. Investigation of OSL signal of resistors from mobile phones for accidental dosimetry

    NASA Astrophysics Data System (ADS)

    Mrozik, A.; Marczewska, B.; Bilski, P.; Gieszczyk, W.

    2014-12-01

    Resistors from mobile phones, usually located near the human body, are considered as individual dosimeters of ionizing radiation in emergency situations. The resistors contain Al2O3, which is optically stimulated luminescence (OSL) material sensitive to ionizing radiation. This work is focused on determination of dose homogeneity within a mobile phones which was carried out by OSL measurements of resistors placed in different parts inside the mobile phone. Separate, commercially available resistors, similar in the shape and size to the resistors from circuit board of the studied mobile phone, were situated in different locations inside it. The irradiations were performed in uniform 60Co and 137Cs radiation fields, with the mobile phones connected and not connected to the cellular network. The dose decrease of 9% was measured for original resistors situated between layer of copper-clad laminate and battery, in comparison to the dose at the front of the phone. The resistors showed the lower signal when the mobile phone was connected to the cellular network, due to higher temperature inside the housing. The profile of fading was investigated within 3 month period for resistors irradiated with 1 Gy of gamma rays to estimate of the fading coefficient.

  5. Chronology and provenance of last-glacial (Peoria) loess in western Iowa and paleoclimatic implications

    USGS Publications Warehouse

    Muhs, Daniel R.; Bettis, E. Arthur; Roberts, Helen M.; Harlan, Stephen S.; Paces, James B.; Reynolds, Richard L.

    2013-01-01

    Geologic archives show that the Earth was dustier during the last glacial period. One model suggests that increased gustiness (stronger, more frequent winds) enhanced dustiness. We tested this at Loveland, Iowa, one of the thickest deposits of last-glacial-age (Peoria) loess in the world. Based on K/Rb and Ba/Rb, loess was derived not only from glaciogenic sources of the Missouri River, but also distal loess from non-glacial sources in Nebraska. Optically stimulated luminescence (OSL) ages provide the first detailed chronology of Peoria Loess at Loveland. Deposition began after ~ 27 ka and continued until ~ 17 ka. OSL ages also indicate that mass accumulation rates (MARs) of loess were not constant. MARs were highest and grain size was coarsest during the time of middle Peoria Loess accretion, ~ 23 ka, when ~ 10 m of loess accumulated in no more than ~ 2000 yr and possibly much less. The timing of coarsest grain size and highest MAR, indicating strongest winds, coincides with a summer-insolation minimum at high latitudes in North America and the maximum southward extent of the Laurentide ice sheet. These observations suggest that increased dustiness during the last glacial period was driven largely by enhanced gustiness, forced by a steepened meridional temperature gradient.

  6. Science Data Center concepts for moderate-sized NASA missions

    NASA Technical Reports Server (NTRS)

    Price, R.; Han, D.; Pedelty, J.

    1991-01-01

    The paper describes the approaches taken by the NASA Science Data Operations Center to the concepts for two future NASA moderate-sized missions, the Orbiting Solar Laboratory (OSL) and the Tropical Rainfall Measuring Mission (TRMM). The OSL space science mission will be a free-flying spacecraft with a complement of science instruments, placed in a high-inclination, sun synchronous orbit to allow continuous study of the sun for extended periods. The TRMM is planned to be a free-flying satellite for measuring tropical rainfall and its variations. Both missions will produce 'standard' data products for the benefit of their communities, and both depend upon their own scientific community to provide algorithms for generating the standard data products.

  7. Proceedings of the Annual Symposium on Frequency Control (42nd) Held in Baltimore, Maryland on 1-3 June 1988

    DTIC Science & Technology

    1988-06-03

    STrRIP IN FiG.2. 402 rV - C U’ 0-Z --. *L ot ’Z - 0o l or Pe T -lo 000r- O*SL- 0,X01- O’SZI- DlOSI- Osl - 00&z- OH/ Pul) IN 1 3v (1 4 d S)S0’I0I I-1...current, ac short-circuit current, and small-signal ac shunt resistance. Sulfur dosimeters were used to determine the All of these quantities were...measured in the photovoltaic incremental neutron fluences. The tolerance 2 of such mode under conditions of constant illumination using the dosimeters

  8. Response of optically stimulated luminescence dosimeters subjected to X-rays in diagnostic energy range

    NASA Astrophysics Data System (ADS)

    Musa, Y.; Hashim, S.; Karim, M. K. A.; Bakar, K. A.; Ang, W. C.; Salehhon, N.

    2017-05-01

    The use of optically stimulated luminescence (OSL) for dosimetry applications has recently increased considerably due to availability of commercial OSL dosimeters (nanoDots) for clinical use. The OSL dosimeter has a great potential to be used in clinical dosimetry because of its prevailing advantages in both handling and application. However, utilising nanoDot OSLDs for dose measurement in diagnostic radiology can only be guaranteed when the performance and characteristics of the dosimeters are apposite. In the present work, we examined the response of commercially available nanoDot OSLD (Al2O3:C) subjected to X-rays in general radiography. The nanoDots response with respect to reproducibility, dose linearity and signal depletion were analysed using microStar reader (Landauer, Inc., Glenwood, IL). Irradiations were performed free-in-air using 70, 80 and 120 kV tube voltages and tube currents ranging from 10 - 100 mAs. The results showed that the nanoDots exhibit good linearity and reproducibility when subjected to diagnostic X-rays, with coefficient of variations (CV) ranging between 2.3% to 3.5% representing a good reproducibility. The results also indicated average of 1% signal reduction per readout. Hence, the nanoDots showed a promising potential for dose measurement in general X-ray procedure.

  9. [Measurement of scatter radiation on MDCT equipment using an OSL dosimeter].

    PubMed

    Tomita, Hironobu; Morozumi, Kunihiko

    2004-11-01

    The recent introduction of multi-detector row computed tomography (MDCT) has made it possible to scan the entire abdomen within approximately 10 sec in procedures such as interventional radiology computed tomography (IVRCT), which are associated with operator exposure. Therefore, anxious patients and patients who are not able to remain still can be examined with an assistant. In the present study, radiation exposure to the assistant was estimated, and the distribution of scattered radiation near the gantry was measured using an optically stimulated luminescence (OSL) dosimeter. Simultaneous measurements were obtained using a direction storage (DIS) dosimeter for reference. The maximum value of 1.47 mSv per examination was obtained at the point closest to the gantry's center (50 cm from the center at a height of 150 cm above the floor) . In addition, scattered radiation decreased as the measurement point was moved further from the gantry's center, falling below the limit of detection (0.1 mSv or less) at 200 cm and at the sides of the gantry. OSL dosimeters are also employed as personal dosimeters, permitting reliable values to be obtained easily. They were found to be an effective tool for the measurement of scattered radiation, as in the present study, helping to provide better understanding of the distribution of scattered radiation within the CT room.

  10. Luminescence dating of the Zeketai loess section in the Ili Basin, northwestern China: Methodological considerations

    NASA Astrophysics Data System (ADS)

    Qin, Jintang; Zhou, Liping

    2018-04-01

    Loess deposits in Xinjiang, northwestern China are ideal archives for past environmental changes in the Westerlies-dominated central Asia. Among previous luminescence dating studies of loess in Xinjiang, few have attempted to systematically investigate the methodological aspects. In this study, we report results of a multiple-procedure luminescence dating of the Zeketai loess section in the Ili Basin, central Xinjiang. Optically stimulated luminescence (OSL) and post-infrared infrared stimulated luminescence (pIRIR) signals were used for quartz and polymineral grains of different sizes. The pIRIR ages obtained with two protocols agree well with each other and constrain the loess deposition between 50 ka and 88 ka. The OSL ages of fine-grained quartz are in stratigraphic order and range from 37 ka to 61 ka, but are ∼30% younger than the pIRIR295 ages of both fine and medium grained polyminerals. Although the causes of the discrepancy between the ages derived from different luminescence dating protocols are still to be understood, we stress that the quartz OSL ages of loess in this region are likely to be underestimated, especially for samples older than 40 ka. The polymineral or potassium feldspar pIRIR signal is recommended for dating loess in the Ili Basin, at least as an internal check.

  11. The notion of climate-driven strath-terrace production assessed via dissimilar stream-process response to late Quaternary climate

    USGS Publications Warehouse

    García, Antonio F.; Mahan, Shannon

    2014-01-01

    Previous research results from the Gabilan Mesa are combined with new optically stimulated luminescence (OSL) age estimates and sedimentological analyses with the aim of identifying factors that inhibit climate-driven strath-terrace production, and factors that make possible strath-terrace production independent of climate forcing. The factors are revealed by comparing the morphostratigraphy and OSL age estimates of terraces in the adjacent San Lorenzo Creek and Pancho Rico Creek drainage basins of the central California Coast Ranges. OSL age estimates on San Lorenzo Creek fill-terrace alluvium overlying bedrock at two paleofluvial levels range between 50.5 and 41.3 ka and between 33.4 and 18.2 ka. These OSL age estimates indicate that although the channel of Pancho Rico Creek was degrading at these times, San Lorenzo Creek aggradation was synchronous with previously documented regional, climatically driven aggradation that elsewhere in southern California led to strath production and alluvial deposition. The regional-scale climate forcing events had different effects on San Lorenzo and Pancho Rico Creeks because of the influences of drainage-basin lithology on bedload size and tectonic tilting direction on base-level fall. The Holocene history of channel denudation and strath production of Pancho Rico Creek is also different from that of San Lorenzo Creek, and different from that of many other streams in southern California. After Pancho Rico Creek captured the upper part of the drainage basin of San Lorenzo Creek sometime after 15.5 to 11.7 ka, Pancho Rico Creek has been producing unpaired, erosional strath terraces. The weak, clay rich, fine-grained sedimentary rock underlying Pancho Rico Valley is an ideal substrate in which to form straths. The meandering channel of Pancho Rico Creek produces straths, and weathering resistant, relatively hard bedload introduced by stream capture ensures their preservation as strath terraces.

  12. Preliminary results of chronostratigraphic field work, OSL-dating and morphogenetic reconstruction of an alluvial apron at Alborz southern foothill, Damghan basin, Iran

    NASA Astrophysics Data System (ADS)

    Büdel, Christian; Fuchs, Markus; Majid Padashi, Seyed; Baumhauer, Roland

    2014-05-01

    Here we present preliminary results of a chronostratigraphic study of an alluvial fan in the Damghan Basin, northern Iran. The basin sediments date back to the Mio- and Pliocene and therefore represent the starting point of alluvial fan aggradation. Today, the still active alluvial fans prograde from the Albors Mountain ranges and sit on the older sediment bodies. In this study, our focus is on the late Pleistocene to Holocene alluvial fan sedimentation history. The upper stratigraphy of the alluvial fans and intercalated lake deposits is characterized by six individual layers of gravels and fines, representing six different stratigraphic units. These units are described and classified by detailed geomorphological and stratigraphic mapping. To establish an alluvial fan chronology, six profiles were sampled for OSL dating. As expected, due to the high-energy transport system of alluvial fan aggradation in semi-desert environments, OSL dating of these sediments is challenging due to the problem of insufficient bleaching. Consequently, most of the samples are interpreted as maximum ages. However, the measurements show a consistent internal age structure and the overall OSL-based chronology is in agreement with the age model derived from our geomorphological analysis. As a first interpretation, based on surveyed geomorphological features and chronological analysis, we could identify seven morphodynamic phases, leading to a genetic model of alluvial fan aggradation. The oldest Pleistocene age estimate is derived from a former lake terrace. The following ages represent ongoing lake sediment deposition and the development of a proximal and mid-fan gravel cover. After the youngest lake deposits were accumulated within the Holocene, the lake starts to retreat and small alluvial fans are filling up the former lake bottom. This last sedimentation phase can be divided in at least two sub-phases, probably coupled to a lateral shifting of the active depositional lobe and to the abandonment and shallow incision of mid fan surfaces.

  13. Evaluation of an X-Ray Dose Profile Derived from an Optically Stimulated Luminescent Dosimeter during Computed Tomographic Fluoroscopy.

    PubMed

    Hasegawa, Hiroaki; Sato, Masanori; Tanaka, Hiroshi

    2015-01-01

    The purpose of this study was to evaluate scatter radiation dose to the subject surface during X-ray computed tomography (CT) fluoroscopy using the integrated dose ratio (IDR) of an X-ray dose profile derived from an optically stimulated luminescent (OSL) dosimeter. We aimed to obtain quantitative evidence supporting the radiation protection methods used during previous CT fluoroscopy. A multislice CT scanner was used to perform this study. OSL dosimeters were placed on the top and the lateral side of the chest phantom so that the longitudinal direction of dosimeters was parallel to the orthogonal axis-to-slice plane for measurement of dose profiles in CT fluoroscopy. Measurement of fluoroscopic conditions was performed at 120 kVp and 80 kVp. Scatter radiation dose was evaluated by calculating the integrated dose determined by OSL dosimetry. The overall percent difference of the integrated doses between OSL dosimeters and ionization chamber was 5.92%. The ratio of the integrated dose of a 100-mm length area to its tails (-50 to -6 mm, 50 to 6 mm) was the lowest on the lateral side at 80 kVp and the highest on the top at 120 kVp. The IDRs for different measurement positions were larger at 120 kVp than at 80 kVp. Similarly, the IDRs for the tube voltage between the primary X-ray beam and scatter radiation was larger on the lateral side than on the top of the phantom. IDR evaluation suggested that the scatter radiation dose has a high dependence on the position and a low dependence on tube voltage relative to the primary X-ray beam for constant dose rate fluoroscopic conditions. These results provided quantitative evidence supporting the radiation protection methods used during CT fluoroscopy in previous studies.

  14. Evaluation of an X-Ray Dose Profile Derived from an Optically Stimulated Luminescent Dosimeter during Computed Tomographic Fluoroscopy

    PubMed Central

    Hasegawa, Hiroaki; Sato, Masanori; Tanaka, Hiroshi

    2015-01-01

    The purpose of this study was to evaluate scatter radiation dose to the subject surface during X-ray computed tomography (CT) fluoroscopy using the integrated dose ratio (IDR) of an X-ray dose profile derived from an optically stimulated luminescent (OSL) dosimeter. We aimed to obtain quantitative evidence supporting the radiation protection methods used during previous CT fluoroscopy. A multislice CT scanner was used to perform this study. OSL dosimeters were placed on the top and the lateral side of the chest phantom so that the longitudinal direction of dosimeters was parallel to the orthogonal axis-to-slice plane for measurement of dose profiles in CT fluoroscopy. Measurement of fluoroscopic conditions was performed at 120 kVp and 80 kVp. Scatter radiation dose was evaluated by calculating the integrated dose determined by OSL dosimetry. The overall percent difference of the integrated doses between OSL dosimeters and ionization chamber was 5.92%. The ratio of the integrated dose of a 100-mm length area to its tails (−50 to −6 mm, 50 to 6 mm) was the lowest on the lateral side at 80 kVp and the highest on the top at 120 kVp. The IDRs for different measurement positions were larger at 120 kVp than at 80 kVp. Similarly, the IDRs for the tube voltage between the primary X-ray beam and scatter radiation was larger on the lateral side than on the top of the phantom. IDR evaluation suggested that the scatter radiation dose has a high dependence on the position and a low dependence on tube voltage relative to the primary X-ray beam for constant dose rate fluoroscopic conditions. These results provided quantitative evidence supporting the radiation protection methods used during CT fluoroscopy in previous studies. PMID:26151914

  15. Luminescence dating of Holocene dune complexes along the shore of northern France (Picardy)

    NASA Astrophysics Data System (ADS)

    Lauer, Tobias; Frechen, Manfred; Meurisse-Fort, Murielle; Gosselin, Guillaume; van Vliet-Lanoë, Brigitte

    2010-05-01

    The Holocene dune and peat complexes along the shore of northern France (Picardy) had already been studied in detail by Meurisse et al. (2005) and Meurisse-Fort (2009). Information about the palaeodevelopment of those dune fields is hence given due to existing 14C data as well as by sedimentological and morphological analyses. Due to the results from radiocarbon dating, different types of aeolian bodies could be correlated along the Picardy coastline and a regional stratigraphic sequence could be established (Meurisse-Fort, 2009). The aim of the ongoing study is to get a higher chronological resolution for the different phases of dune activity in Picardy by luminescence dating what is a powerful tool to determine the time of last sunlight exposure of grains before burial (this information yields important information about dune movement). Samples for OSL dating were taken from dune bodies located in Tardinghen, Hardelot, Saint-Frieux and Saint-Gabriel. For dating, a single aliquot regenerative dose (SAR) protocol (Murray & Wintle 2003) is applied to coarse grained quartz. First tests concerning the signal intensity, the purity of the quartz OSL signal and the bleaching properties showed that quartz OSL dating works well for the dunes of the northern France coastline. The new luminescence ages will help to better unravel the phases of sand dune activity and stabilisation mainly controlled by climate changes and human impact. References: Meurisse, M., Van Vliet-Lanoë, B., Talon, B. & Recourt, P. (2005): Complexes dunaires et tourbeux holocènes du littoral du Nord de la France. - Geoscience, 337 : 675-684. Meurisse-Fort, M. (2009): Enregistrement haute résolution des massifs dunaires ; Manche, mer du Nord et Atlantique - Le rôle des tempêtes. Thèse de Doctorat soutenue en juin 2007, Université de Lille1. Coll. Recherches - Sciences (Sciences de la Terre). EPU-Publibook (ed.), Paris, 310 pp. Murray, A.S. & Wintle, A.G. (2003): The single aliquot regenerative dose protocol: potential for improvements in reliability. - Radiat. Meas., 37: 377-381.

  16. Thermochronometry using red TL of quartz - a feasibility study from in-situ drill-hole samples

    NASA Astrophysics Data System (ADS)

    Schmidt, Christoph; Zöller, Ludwig

    2015-04-01

    Thermochronometry - the revelation of the temperature history of rock related to subsidence or uplift and erosion - relies on methods with closure temperatures >40-70 °C, such as (U-Th-Sm)/He or fission track analysis on apatite. These methods are applicable to young and tectonically active mountain ranges, but results of calculated mean denudation rates are too imprecise for older orogens. Several studies attested the quartz luminescence signal (325 °C TL peak, OSL fast component) isothermal decay at ambient temperatures as low as 56 °C (Prokein and Wagner, 1994; Herman et al., 2010; de Sarkar et al., 2013). The so far determined closure temperatures of the quartz luminescence thermochronometry system vary between ~35 °C for the OSL fast component (Herman et al., 2010) and ~70 °C for red thermoluminescence (RTL; Tsuchiya and Fujino, 2000) and are dependent on the cooling rate and the charge trap parameters. Although featuring a favourably low closure temperature - thus allowing to study the geologically most recent temperature history -, especially quartz OSL suffers from low dose saturation, limiting the application to highly erosive orogens. Saturation doses of RTL exceed those of OSL by a factor of 10 or more (Fattahi and Stokes, 2000), what opens up new perspectives in low-temperature thermochronometry. We here present experimental results on the general suitability of RTL for thermochronometry, obtained for samples from a drilling hole in the granitic basement of the Variscan Fichtelgebirge (Franconia, Germany). The samples allowed studying the RTL signal saturation level in-situ at different ambient temperatures up to ~55 °C (at 1831 m depth). Measurements confirmed depletion of the 325 °C RTL peak for ambient temperatures >25 °C, most probably for even lower temperatures. Irradiation experiments showed that the RTL signal is not in saturation for ambient temperatures >25 °C, even for this 'old' mountain range. We could further demonstrate that the luminescence sensitivity of samples strongly increases with rising ambient temperature, opposite to the findings of Ypma and Hochman (1991) for samples from sedimentary basins. References Fattahi, M., Stokes, S., 2000. Extending the time range of luminescence dating using red TL (RTL) from volcanic quartz. Radiation Measurements 32, 479-485. Herman, F., Rhodes, E.J., Braun, J., Heiniger, L., 2010. Uniform erosion rates and relief amplitude during glacial cycles in the Southern Alps of New Zealand, as revealed from OSL-thermochronology. Earth and Planetary Science Letters 297, 183-189. Prokein, J., Wagner, G.A., 1994. Analysis of thermoluminescent glow peaks in quartz derived from the KTB-drill hole. Radiation Measurements 23, 85-94. de Sarkar, S., Mathew, G., Pande, K., Chauhan, N., Singhvi, A.K., 2013. Rapid denudation of Higher Himalaya during late Pleistocence, evidence from OSL thermochronology. Geochronometria 40, 304-310. Tsuchiya, N., Fujino, K., 2000. Evaluation of cooling history of the Quaternary Takidani pluton using thermoluminescence technique. Proceedings World Geothermal Congress, Kyushu-Tohoku, Japan. Ypma, P.J., Hochman, M.B., 1991. Thermoluminescence geothermometry - a case study of the Otway basin. APEA Journal, 312-324.

  17. Dating ancient mosaic glasses by luminescence: The case study of San Pietro in Vaticano

    NASA Astrophysics Data System (ADS)

    Galli, A.; Martini, M.; Sibilia, E.; Vandini, M.; Villa, I.

    2011-12-01

    The preliminary results of a study on the dosimetric properties of a set of glass tesserae from the mosaics of the vaults of St. Peter's Basilica in Rome (late XVI century) are reported. The main goal of the research was to assess the possibility of dating them by means of luminescence techniques. The samples had already been extensively studied and investigated from a historical, artistic and compositional point of view. The period of the making of the mosaic was rather well known, and could be the basis to test the experimental procedures we used for dosimetry. The experiments also aimed at demonstrating the validity of the hypothesis we put forward, i.e. the positive link between the presence of micro-crystals and the luminescence sensitivity in mosaic glass: to this aim, the samples richer in crystalline inclusions were selected. The role of calcium antimonate and cassiterite was definitely demonstrated. For what concerns their thermoluminescence (TL) characteristics, a preliminary investigation suggested that the available configuration of the detection systems did not properly fit the wavelength of the emitted TL. Much more promising results have been achieved by the use of Optically Stimulated Luminescence (OSL), even if the measured absorbed doses were rather scattered. For one sample with high OSL sensitivity, it was possible to establish its recent age, relative to one of the documented restorations that took place during the last century.

  18. Investigation of the response characteristics of OSL albedo neutron dosimeters in a 241AmBe reference neutron field

    NASA Astrophysics Data System (ADS)

    Liamsuwan, T.; Wonglee, S.; Channuie, J.; Esoa, J.; Monthonwattana, S.

    2017-06-01

    The objective of this work was to systematically investigate the response characteristics of optically stimulated luminescence Albedo neutron (OSLN) dosimeters to ensure reliable personal dosimetry service provided by Thailand Institute of Nuclear Technology (TINT). Several batches of InLight® OSLN dosimeters were irradiated in a reference neutron field generated by the in-house 241AmBe neutron irradiator. The OSL signals were typically measured 24 hours after irradiation using the InLight® Auto 200 Reader. Based on known values of delivered neutron dose equivalent, the reading correction factor to be used by the reader was evaluated. Subsequently, batch homogeneity, dose linearity, lower limit of detection and fading of the OSLN dosimeters were examined. Batch homogeneity was evaluated to be 0.12 ± 0.05. The neutron dose response exhibited a linear relationship (R2=0.9974) within the detectable neutron dose equivalent range under test (0.4-3 mSv). For this neutron field, the lower limit of detection was between 0.2 and 0.4 mSv. Over different post-irradiation storage times of up to 180 days, the readings fluctuated within ±5%. Personal dosimetry based on the investigated OSLN dosimeter is considered to be reliable under similar neutron exposure conditions, i.e. similar neutron energy spectra and dose equivalent values.

  19. Scintillation and storage luminescence properties of MgF2 transparent ceramics doped with Ce3+

    NASA Astrophysics Data System (ADS)

    Nakamura, Fumiya; Kato, Takumi; Okada, Go; Kawaguchi, Noriaki; Fukuda, Kentaro; Yanagida, Takayuki

    2017-10-01

    In this paper, we report basic optical properties and scintillation and storage luminescence properties of MgF2:Ce transparent ceramics with different doping concentrations of Ce (0.01, 0.1 and 1%) synthesized by spark plasma sintering (SPS). In scintillation, thermally-stimulated luminescence (TSL) and optically-stimulated luminescence (OSL), the dominant emissions were due to the 5d-4f transitions of Ce3+ which appeared in the near-UV region peaking around 320 and 360 nm. The scintillation was evaluated by X-ray irradiation while OSL was observed under 540 nm stimulation. In particular, the TSL sensitivity was high and showed a good linearity from 0.1 mGy to 1000 mGy.

  20. A luminescence dating study of the sediment stratigraphy of the Lajia Ruins in the upper Yellow River valley, China

    NASA Astrophysics Data System (ADS)

    Zhang, Yuzhu; Huang, Chun Chang; Pang, Jiangli; Zhou, Yali; Zha, Xiaochun; Wang, Longsheng; Zhou, Liang; Guo, Yongqiang; Wang, Leibin

    2014-06-01

    Pedo-sedimentological fieldwork were carried out in the Lajia Ruins within the Guanting Basin along the upper Yellow River valley. In the eolian loess-soil sections on the second river terrace in the Lajia Ruins, we find that the land of the Qijia Culture (4.20-3.95 ka BP) are fractured by several sets of earthquake fissures. A conglomerated red clay covers the ground of the Qijia Culture and also fills in the earthquake fissures. The clay was deposited by enormous mudflows in association with catastrophic earthquakes and rainstorms. The aim of this study is to provide a luminescence chronology of the sediment stratigraphy of the Lajia Ruins. Eight samples were taken from an eolian loess-soil section (Xialajia section) in the ruins for optically stimulated luminescence (OSL) dating. The OSL ages are in stratigraphic order and range from (31.94 ± 1.99) ka to (0.76 ± 0.02) ka. Combined OSL and 14C ages with additional stratigraphic correlations, a chronological framework is established. We conclude that: (1) the second terrace of the upper part of Yellow River formed 35.00 ka ago, which was followed by the accumulation of the eolian loess-soil section; and (2) the eolian loess-soil section is composed of the Malan Loess of the late last glacial (MIS-2) and Holocene loess-soil sequences.

  1. OSL - Orbiting Solar Laboratory: Our Window on the Sun

    NASA Technical Reports Server (NTRS)

    1991-01-01

    The Sun, the nearest star, is crucial for life on Earth and has always been an object of intense study. Indeed, many of the fundamental principles of astrophysics, which seek to understand the physical nature of the universe, have been established through study of the Sun. Magnetic activity with the Sun drives powerful events on its surface and in its atmosphere. From the the Earth, these events can be seen as active region with their sunspots and solar flares. But to observe such phenomena in detail require more finely-tuned and powerful instruments, operating in space, across a broader range of the electomagnetic spectrum, than have ever been available in the past. Earth's atmosphere has always blurred the images received by visible-light telescopes on the ground. The atmosphere also acts as a barrier to the ultraviolet, extreme ultraviolet, and x rays that are similarly emitted from the Sun. All these wavelengths need to be captured, at the same moment in time, before the complex interrelationships of solar activity can be truly understood. The Orbiting Solar Laboratory (OSL), the prime NASA solar mission for the 1990's, is uniquely designed to 'see' across the wavelengths and so observe the fine evolving details of a wide range of phenomena on the surface of the Sun. By the turn of the century, OSL will enable scientists to solve mysteries that humankind has sought to unravel for thousands of years.

  2. Dose profiles for lung and breast regions at prospective and retrospective CT coronary angiography using optically stimulated luminescence dosimeters on a 64-detector CT scanner.

    PubMed

    Funama, Yoshinori; Taguchi, Katsuyuki; Utsunomiya, Daisuke; Oda, Seitaro; Murasaki, Hiroo; Yamashita, Yasuyuki; Awai, Kazuo

    2012-01-01

    The purpose of our study was to acquire dose profiles at critical organs of lung and breast regions using optically stimulated luminescence (OSL) dosimeters; assess the actual radiation dose delivered at retrospective and prospective computed tomography coronary angiography (CTCA). Using a chest CT phantom we applied a prospectively-gated step-and-shoot- and a retrospectively-gated helical mode on a 64-detector row CT scanner. Retrospective scan mode was used with and without electrocardiogram (ECG) based tube current modulation. OSL dosimeters were used to measure dose profiles. In the both scan modes we acquired dose profiles and determined the mean and maximum dose in left lung and in left breast regions. In prospective mode, the mean dose was 21.53 mGy in left lung- and 23.59 mGy in left breast region. With respect to the retrospective mode, the mean dose with tube current modulation was 38.63 mGy for left lung- and 46.02 mGy for left breast region, i.e. 0.56 and 0.55 times lower than the mean dose without modulation. The OSL dosimeter is useful for measurement of the actual radiation dose along z-axis at lung and breast regions in the prospective and the retrospective CTCA. Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  3. A comparative evaluation of luminescence detectors: RPL-GD-301, TLD-100 and OSL-AL2O3:C, using Monte Carlo simulations

    NASA Astrophysics Data System (ADS)

    Benali, A.-H.; Medkour Ishak-Boushaki, G.; Nourreddine, A.-M.; Allab, M.; Papadimitroulas, P.

    2017-07-01

    The luminescent dosimeters are widely used in clinical practice, for the monitoring of patient dose in external radiation therapy. Three of the most common dosimeter categories are the thermoluminescence (TLDs), the radiophotoluminescence (RPLs) and the optically stimulated luminescence (OSLs), with similar physical processes on their properties. The aim of the present study is to compare and evaluate the dosimetric properties of three specific luminescent detectors namely: a) RPL glass dosimeter, commercially known as GD-301, b) lithium fluoride TLD-100 (LiF:Mg,Ti) and c) carbon-doped aluminum oxide (Al2O3:C). For this purpose, Monte Carlo simulations were applied, using the MCNP5 code to estimate the responses of these dosimeters in terms of absorbed dose, output factor, the angular and energy dependence. In the present study, we found that the differences between the output factors were less than ± 4.2% for all detector materials RPLGD, TLD and OSLD. The variations in sensitivity for angles up to ± 80 degrees from the central axis of the beam were approximately 0.5%, 0.8% and 1.5% for the TLD-100, GD-301 and Al2O3:C, respectively. The energy dependence of the RPL and OSL dosimeters are stated as less than a 2.2%, and within 5.8% for TLD.

  4. New optically stimulated luminescence ages provide evidence of MIS3 and MIS2 eolian activity on Black Mesa, northeastern Arizona, USA

    USGS Publications Warehouse

    Ellwein, A.L.; Mahan, S.A.; McFadden, L.D.

    2011-01-01

    Eolian deposition on the semiarid southern Colorado Plateau has been attributed to episodic aridity during the Quaternary Period. However, OSL ages from three topographically controlled (e.g. falling) dunes on Black Mesa in northeastern Arizona indicate that eolian sediments there were deposited in deep tributary valleys as early as 35-30. ka, with most sand deposited before 20. ka. In contrast, the oldest OSL ages for sand sheets fall within the Pleistocene-Holocene climatic transition (~. 12-8. ka). Thus most eolian sediment accumulated on Black Mesa under climatic conditions that were in general cooler, moister, and more variable than today, not more arid, pointing to a considerable increase in sediment supply. ?? 2010 University of Washington.

  5. TL and OSL properties of beta irradiated Y2O3 nanocrystal

    NASA Astrophysics Data System (ADS)

    Shivaramu, N. J.; Lakshminarasappa, B. N.; Nagabhushana, K. R.; Tatumi, S. H.; Rocca, R. R.; Singh, Fouran

    2017-05-01

    Nanocrystalline yttrium oxide (Y2O3) is synthesized by low temperature sol-gel technique and synthesized material is annealed at 900°C. The annealed β-rayed Y2O3 two TL glows with prominent peak at 407 K and weak glow peak at 643 K were observed in all irradiated samples. It is found that TL glow peaks intensity linearly increases with increase in β-dose from 0.813 - 40.625 Gy. The TL kinetic parameters are calculated using glow curve deconvoluted (GCD) method. The TL glows exhibits general order kinetics. Intense optical stimulated luminescence (OSL) is observed in the Y2O3 sample. These material exhibits linearity and reproducibility and hence, it suggests that this material may be used as dosimetric applications.

  6. Provenance of sands from the confluence of the Amazon and Madeira rivers based on detrital heavy minerals and luminescence of quartz and feldspar

    NASA Astrophysics Data System (ADS)

    do Nascimento, Daniel R.; Sawakuchi, André O.; Guedes, Carlos C. F.; Giannini, Paulo C. F.; Grohmann, Carlos H.; Ferreira, Manuela P.

    2015-03-01

    Source-to-sink systems are poorly known in tropical rivers. For the Amazonian rivers, the majority of the provenance studies remain focused on the suspended load, implying a poor understanding of the processes governing production and distribution of sands. In this study, we perform heavy mineral and optically stimulated luminescence (OSL) analysis to cover the entire spectrum (heavy and light minerals fraction) of 29 sand samples of the Lower Madeira river region (Amazon and Madeira rivers), of which the main goal was to find provenance indicators specific to these rivers. Despite the tropical humid climate, the sands of the Amazon and Lower Madeira rivers are rich in unstable heavy minerals as augite, hypersthene, green hornblende and andalusite. The Madeira river is highlighted by its higher content of andalusite, with source attributed to the Amazon Craton (medium-to-high grade metamorphic rocks), while the Amazon river, upstream of the Madeira river mouth, has a signature of augite and hypersthene, that suggests an Andean provenance (volcanic rocks). Sands from the Madeira river can be tracked in the Amazon river by the increasing concentration in andalusite. OSL analysis of the light minerals fraction was used as an index of feldspar concentration and sedimentary history of quartz grains. Lower feldspar concentration and quartz grains with longer sedimentary history (higher OSL sensitivity) also point to a major contribution of cratonic sources for the sands in the Madeira river. While the sands from the Lower Madeira would be mainly supplied by cratonic rocks, previous work recognised that suspended sediments (silt and clay) are derived from Andean rocks. Therefore, we interpret a decoupling between the sources of sand and mud (silt and clay) under transport in the Madeira river. Andean sands (rich in augite and hypersthene) would be trapped in the foreland zones of the Beni and Mamoré tributaries. In the Amazon river sands, the low OSL sensitivity of the quartz, higher content of feldspar and unstable heavy mineral assemblage dominated by augite and hypersthene suggest both a fast transport from Andean sources with fine sediment bypass over foreland areas.

  7. Preliminary constraints on the kinetics of OSL thermochronology

    NASA Astrophysics Data System (ADS)

    Guralnik, B.; Herman, F.; Lowick, S.; Preusser, F.; Rhodes, E. J.

    2010-12-01

    Utilizing the fact that temperature exerts a strong control on the retention of radiogenic products at their production sites (and hence their rate of accumulation), thermochronology is an extension of geochronology used to elucidate the cooling histories (t-T trajectories) of rocks over time (Dodson, 1973). Here we present a potential thermochronometer based on the optically stimulated luminescence (OSL) signal of bedrock quartz, with an estimated “closure” temperature of ~25-40°C (-dT/dt=10°C/Ma). In this method, the radiogenic “products” measured are electrons trapped at the naturally occurring lattice defects (electrically unbalanced sites). These electrons can be subsequently released back into the conduction band by exposure to heat and/or light. The mean lifetime of an electron in a particular trapping site is well described by an Arrhenius relationship of the form τ=s-1exp(-E/kT), where E and s are activation energy and frequency factors, respectively, and k is Boltzmann’s constant. Reported lifetimes of the major trap types at 20°C are well beyond Ma-timescale, but for typical natural radioactivity dose rates, these traps saturate well before ~0.5 Ma. In the current work, we analyzed the OSL signals of bedrock quartz from the KTB-VB drillhole (Southern Germany), where long-term stable temperature conditions provide a natural isothermal holding experiment at a Ma-timescale. Eleven core samples from a depth range of 560 m - 2335 m (22°C - 71°C, respectively), were processed to obtain an unbleached quartz fraction of 180-250 µm. Natural and regenerated luminescence signals were measured by stimulation with infrared and then blue light using a single-aliquot regeneration (SAR) protocol. As a function of sample depth, the measured OSL signal varies from a saturated signal at shallow depths to reset signals below a depth of 1 km (i.e., ambient rock temperature higher than 40°C). Several unstable trapping sites with potentially different closure temperatures are suggested by comparison of the natural to regenerated signals.

  8. Stratigraphic Reconstruction of a Late Pleistocene Cypress Forest Discovered on the Northern Gulf of Mexico Continental Shelf

    NASA Astrophysics Data System (ADS)

    Gonzalez Rodriguez, S. M.; Bentley, S. J.; Obelcz, J.; Truong, J. T.; DeLong, K. L.; Xu, K.; Harley, G. L.; Reese, C. A.; Caporaso, A.; Shen, Z.

    2017-12-01

    A previously buried bald cypress forest (Taxodium distichum) was discovered on the continental shelf, offshore of Orange Beach, Alabama, USA, in 20 m water depth. The forest was possibly exhumed by Hurricane Ivan in 2004, and is now exposed as stumps in life position in a trough located in the northern Gulf of Mexico continental shelf seafloor. We are investigating the local stratigraphy, paleo-landscape, and mode of forest preservation of this unique site. In August 2015 and July 2016, submersible vibracores (18 in total) were collected. Core analysis included: bulk density and imaging via Geotek multi sensor core logger, sediment grain size, structure, and organic content via loss-on-ignition. Selected samples have been dated using 14C and optically stimulated luminescence (OSL) methods. Multibeam and CHIRP subbottom bathymetry provide context for litho- and chrono-stratigraphy of the site. Integration of core lithostratigraphy and modern shelf bathymetry reveal Holocene transgressive sands blanketing diverse sedimentary facies that are truncated by the late Pleistocene-early Holocene ravinement. Deposits below the ravinement surface include interbedded sand and mud (exact age unknown, but possibly pertaining to a shallow marine environment), overlying a floodplain/swamp facies of woody debris, peat, and mud (provisionally dated by 14C to 41-45 ka). These units grade laterally into paleosols that appear to be 10-15 ka older, based on recently obtained preliminary OSL dates. Occurrence of paleosols and swamp deposits of broadly similar age and elevation suggests that the ancient landscape possessed topographic relief that allowed wetland and upland habitats to develop in close proximity. These new OSL dates enhance our initial hypothesis that floodplain aggradation in the area was a key factor that might have allowed forest preservation. The timing of temporary sea level rises (SLR) ca. 40 and 60 ka. with our 14C and preliminary OSL dates, suggests that floodplain aggradation associated with SLRs could have buried the swamp and forest sediments. Variable paleo-topography in the area at the time of burial provided enough sediment to keep the cypress forest blanketed, withstanding periods of erosion as sea level fluctuated through the late Pleistocene to Holocene, thus facilitating forest preservation.

  9. SU-G-IeP2-04: Dosimetric Accuracy of a Monte Carlo-Based Tool for Cone-Beam CT Organ Dose Calculation: Validation Against OSL and XRQA2 Film Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chesneau, H; Lazaro, D; Blideanu, V

    Purpose: The intensive use of Cone-Beam Computed Tomography (CBCT) during radiotherapy treatments raise some questions about the dose to healthy tissues delivered during image acquisitions. We hence developed a Monte Carlo (MC)-based tool to predict doses to organs delivered by the Elekta XVI kV-CBCT. This work aims at assessing the dosimetric accuracy of the MC tool, in all tissue types. Methods: The kV-CBCT MC model was developed using the PENELOPE code. The beam properties were validated against measured lateral and depth dose profiles in water, and energy spectra measured with a CdTe detector. The CBCT simulator accuracy then required verificationmore » in clinical conditions. For this, we compared calculated and experimental dose values obtained with OSL nanoDots and XRQA2 films inserted in CIRS anthropomorphic phantoms (male, female, and 5-year old child). Measurements were performed at different locations, including bone and lung structures, and for several acquisition protocols: lung, head-and-neck, and pelvis. OSLs and film measurements were corrected when possible for energy dependence, by taking into account for spectral variations between calibration and measurement conditions. Results: Comparisons between measured and MC dose values are summarized in table 1. A mean difference of 8.6% was achieved for OSLs when the energy correction was applied, and 89.3% of the 84 dose points were within uncertainty intervals, including those in bones and lungs. Results with XRQA2 are not as good, because incomplete information about electronic equilibrium in film layers hampered the application of a simple energy correction procedure. Furthermore, measured and calculated doses (Fig.1) are in agreement with the literature. Conclusion: The MC-based tool developed was validated with an extensive set of measurements, and enables the organ dose calculation with accuracy. It can now be used to compute and report doses to organs for clinical cases, and also to drive strategies to optimize imaging protocols.« less

  10. Optimizing combined GPR, OSL and LiDAR (GOaL) to extract paleoenvironmental records and decipher shoreline evolution

    NASA Astrophysics Data System (ADS)

    Dougherty, A. J.; Choi, J. H.; Turney, C. S.; Dosseto, A.

    2017-12-01

    Records of past sea levels, storms, sediment supply and their impacts on the coastline are crucial for projecting likely shoreline changes resulting from anthropogenic warming. High-resolution geophysics, geochronology, and remote sensing techniques offer an optimal way to extract these records and decipher shoreline evolution. These methods include Light Detection and Ranging (LiDAR for imaging barrier morphologies in three dimensions), Ground Penetrating Radar (GPR for detecting paleo-dune, beach and nearshore stratigraphy) and Optically Stimulated Luminescence (OSL for dating deposition of sand grains along paleoshorelines). Each of these teqniques have been applied to coastal research over the decades since they were first introduced. Recently there has been a rapid increase their use since LiDAR became more available, GPR more user-friendly, and OSL more accessible. These methods have the potential to produce both detailed and voluminous datasets that can overwhelm or obscure significant features, such that discrepancies in analysis and/or presentation may lead to erroneous interpretations. In contrast, when utilized correctly on prograded barriers these methods (independently or in various combinations) have produced storm records, constructed sea-level curves, quantified sediment budgets, and deciphered coastal evolution. Therefore, combining the application of GPR, OSL, and LiDAR (GOaL) on one prograded barrier has the potential to generate detailed records of storms, sea level, and sediment supply for that coastline. Obtaining this GOaL hat-trick can provide valuable insights into how these three factors influenced past and future barrier evolution. Here we argue that systematically achieving GOaL hat-tricks on some of the 300+ prograded barriers worldwide would allow us to disentangle local patterns of sediment supply from regional effects of storms or global changes in sea level, allowing direct comparison to climate proxy records. To fully realize this aim requires standardization of methods to optimize results. The impetus for this initiative is to establish a framework for consistent data analysis that maximizes the potential of GOaL to contribute to climate change research and assist coastal communities in mitigating future impacts of global warming.

  11. Mid-Holocene stabilization of the Karakum and Kyzylkum sand seas, central Asia - evidence from OSL ages

    NASA Astrophysics Data System (ADS)

    Maman, Shimrit; Tsoar, Haim; Blumberg, Dan G.; Porat, Naomi

    2013-04-01

    Sand seas (ergs) are large areas of deserts covered by wind-swept sand with varying degrees of vegetation cover. The Kyzylkum and Karakum ergs have accumulated in the Turan basin, northwest of the Hindu Kush range, and span from south Turkmenistan to the Syrdarya River in Kazakhstan. These ergs are dissected by the Amudarya River; To the north lies the Kyzylkum (red sands) and to the south the Karakum (black sands). This area is understudied, and little information has been published regarding the sands stabilization processes and deposition ages. This research focuses on identifying and mapping the ergs of Central Asia and analyzing the climate factors that set the dunes into motion and that stabilized them. A variety of spaceborne imagery with varying spectral and spatial resolutions was used. These images provide the basis for mapping sand distribution, dune forms, and vegetation cover. Wilson (1973) defined these ergs as active based on precipitation. Our results show that they are mostly stabilized, with an estimated area of ~260,000 sq. Km for Kara-Kum , and ~195,500 sq. Km for the Kyzyl-Kum . Meteorological analysis of wind and precipitation data indicate a low wind energy environment (DP<200) and sufficient rainfall (>100 mm) to which is essential for vegetation cover. We present the first optically stimulated luminescence (OSL) ages from the upper meter of 14 exposed sections from both ergs. The age of the sand samples was determined as ~Mid-Holocene by OSL, which provides an insight into past climate characteristics. These ages indicate extensive sand and dune stabilization during the Mid-Holocene. GIS analysis was performed in parallel with field work to validate and verify the results. The OSL ages, coupled with a compilation of regional palaeoclimatic data, corroborate and reinforce the previously proposed Mid-Holocene Liavliakan phase, known to reflect a warmer, wetter, less windy climate than persists today and that resulted in dune stabilization around Mid-Holocene. This study emphasizes the importance of regional climatic control on aeolian activity and is the first to show when these vast sand seas were stabilized.

  12. Central Asian sand seas climate change as inferred from OSL dating

    NASA Astrophysics Data System (ADS)

    Maman, Shimrit; Tsoar, Haim; Blumberg, Dan; Porat, Naomi

    2014-05-01

    Luminescence dating techniques have become more accessible, widespread, more accurate and support studies of climate change. Optically stimulated luminescence (OSL) is used to determine the time elapsed since quartz grains were last exposed to sunlight, before they were buried and the dune stabilized. Many sand seas have been dated extensively by luminescence, e.g., the Kalahari, Namib the Australian linear dunes and the northwestern Negev dune field, Israel. However, no ages were published so far from the central Asian sand seas. The lack of dune stratigraphy and numerical ages precluded any reliable assessment of the paleoclimatic significance of dunes in central Asia. Central Asian Sand seas (ergs) have accumulated in the Turan basin, north-west of the Hindu Kush range, and span from south Turkmenistan to the Syr-Darya River in Kazakhstan. These ergs are dissected by the Amu-Darya River; to its north lies the Kyzylkum (red sands) and to its south lies the Karakum (black sands). Combined, they form one of the largest sand seas in the world. This area is understudied, and little information has been published regarding the sands stabilization processes and deposition ages. In this study, OSL ages for the Karakum and Kyzylkum sands are presented and analysis of the implications of these results is provided. Optical dates obtained in this study are used to study the effects climatic changes had on the mobility and stability of the central Asian sand seas. Optically stimulated luminescence ages derived from the upper meter of the interdune of 14 exposed sections from both ergs, indicate extensive sand and dune stabilization during the mid-Holocene. This stabilization is understood to reflect a transition to a warmer, wetter, and less windy climate that generally persisted until today. The OSL ages, coupled with a compilation of regional paleoclimatic data, corroborate and reinforce the previously proposed Mid-Holocene Liavliakan phase, known to reflect a warmer, wetter, and less windy climate that persists until today and resulted in dune stabilization around the Mid-Holocene. This study, solidifies our results regarding the Kyzylkum and Karakum sand seas dynamics, ages, and emphasizes the importance of regional climatic control on aeolian activity.

  13. Soil development in OSL dated sandy dune substrates under Quercus robur Forest (Netherlands)

    NASA Astrophysics Data System (ADS)

    van Mourik, J. M.; Nierop, Ir. K.; Verstraten, J. M.

    2009-04-01

    Coastal dune landscapes are very dynamic. The present distribution of vegetation and soil is the result of over 2000 years of natural processes and human management. The initial soil development was controlled by an increase of the organic matter content, which consisted mainly of decomposed roots of grasses (rhizomull), and a decrease of the soil pH to 3-4 by decalcification. This stage was followed by the development of a deciduous forest, which was dominated by Quercus robur. Since 1600 AD, a large part of the deciduous forest that dominated the east side of the coastal dune landscape transferred in expensive residential areas and urbanizations. Nevertheless some parts of the oak forest belt remained. The present forest soils are acid and the controlling soil processes are leaching of sesquioxides and storage of organic matter in mormoder humus forms. The sustainability of ecosystems is closely related to the quality of the humus form, controlling nutrient cycling and water supply. Therefore, improve of knowledge of humus form development and properties is important. We applied soil micromorphology and pyrolysis-gas chromatography/mass spectrometry (GC/MS) to investigate more details of humus form development at two locations (Duivendrift and Hoek van Klaas) in the coastal dune area of the Amsterdamse Waterleidingduinen (near Haarlem, the Netherlands). However, to understand forest soil development, including the organic matter composition in the humus form, the age of the substrate and the forest is required. Therefore, we used tradition techniques as pollen analysis and radiocarbon dating but also the recently introduced optical stimulated luminescence (OSL) dating technique. OSL dating works excellent for aeolian sandy deposits with a high percentage of quartz grains. The OSL age is defined as the time after the last bleaching by solar radiation of mineral grains. Or in other words, the start of a stable period without sand drifting. In the Ah horizons we observed palynological traces of a former dune landscape with grasses and typical dune land shrubs. The F and H horizons were dominated by Quercus pollen. In thin sections we found that in the upper part of the F horizons the soil skeleton was formed by leaf litter fragments that were fragmented and decomposed by fungi and micro arthropods. The soil skeleton of the lower part of the F horizons consisted of a mixture of leaf litter fragments and (dead) root fragments. In this part of the profile, fungi and micro arthropods were also responsible for the physical and chemical organic matter decomposition. The soil skeleton of the Ah horizons was formed by mineral grains in which small sized organic aggregates occurred. These aggregates may have four possible sources: (1) sinsedimentary aggregates, involved in sand drifting, (2) fecal relicts from decomposed (older) roots of a former dune land vegetation, (2) fecal relicts from decomposed (younger) roots of the forest and its understory, and (3) infiltrated parts of fecal pallets from the overlying F horizons. The calibrated radiocarbon dates of organic matter from the upper 5 cm of the Ah horizons go back to around 1960 AD. This points to a 45 year period for the development of the ectorganic horizons, assuming that fresh organic matter did not ‘contaminate' the radiocarbon dating. The OSL the ages of quartz grains from the upper 5 cm of the Ah horizons indicate landscape stabilization around 1800AD implying that two centuries were available for vegetation and soil development. There seems to be a significant difference between the OSL and 14C ages of the top of the Ah horizon. The OSL dates are very reliable. They indicate the correct time of the transformation of drift sand into stable, vegetated landscape. The pollen spectra of the Ah horizon show traces of dune grass and shrub landscape, but probably these pollen grains originate from sinsedimentary organic aggregates. And during the juvenile phase of a quercus forest, the quercus pollen production is very low and other wind pollinated grains from dune grasses and shrubs can dominate the pollen spectra. Based upon OSL dates, a period of 200 year forest soil development is more reliable than the 14C based 45 year. We must reject the 14C ages, due to complexity of sources of soil organic matter in the Ah horizon The organic matter as investigated by analytical pyrolysis and thermally assisted hydrolysis and methylation and subsequent analysis by GC/MS revealed a major oak-derived picture. The L+F1 horizons reflected relatively undecomposed organic matter mainly derived from leaves. By contrast, in both F2+H and the Ah horizons leaf material was accompanied by root-derived components, particularly suberin. The latter may originate from barks as well, but in the Ah horizons the contribution of roots was most probably much greater. Apart from a common transformation pattern (decrease of polysaccharides, degradation of lignin and accumulation of lipids), a very small contribution of C26 alkanol indicated a chemical fingerprint of the previous grass vegetation. In conclusion: chemical analysis confirmed the soil micromorphological data, and the application of OSL dating improves our knowledge about geochronology of the system.

  14. CW-OSL measurement protocols using optical fibre Al2O3:C dosemeters.

    PubMed

    Edmund, J M; Andersen, C E; Marckmann, C J; Aznar, M C; Akselrod, M S; Bøtter-Jensen, L

    2006-01-01

    A new system for in vivo dosimetry during radiotherapy has been introduced. Luminescence signals from a small crystal of carbon-doped aluminium oxide (Al2O3:C) are transmitted through an optical fibre cable to an instrument that contains optical filters, a photomultiplier tube and a green (532 nm) laser. The prime output is continuous wave optically stimulated luminescence (CW-OSL) used for the measurement of the integrated dose. We demonstrate a measurement protocol with high reproducibility and improved linearity, which is suitable for clinical dosimetry. A crystal-specific minimum pre-dose is necessary for signal stabilisation. Simple background subtraction only partially removes the residual signal present at long integration times. Instead, the measurement protocol separates the decay curve into three individual components and only the fast and medium components were used.

  15. Assessing sedimentation rates at Usumacinta and Grijalva river basin (Southern Mexico) using OSL and suspended sediment load analysis: A study from the Maya Classic Period

    NASA Astrophysics Data System (ADS)

    Munoz-Salinas, E.; Castillo, M.; Sanderson, D.; Kinnaird, T.; Cruz-Zaragoza, E.

    2013-12-01

    Studying sedimentation rates on floodplains is key to understanding environmental changes occurred through time in river basins. The Usumacinta and Grijalva rivers flow most of their travel through the southern part of Mexico, forming a large river basin, crossing the states of Chiapas and Tabasco. The Usumacinta-Grijalva River Basin is within the 10 major rivers of North America, having a basin area of ~112 550 km2. We use the OSL technique for dating two sediment profiles and for obtaining luminescence signals in several sediment profiles located in the streambanks of the main trunk of the Usumacinta and Grijalva rivers. We also use mean annual values of suspended sediment load spanning ~50 years to calculate the sedimentation rates. Our OSL dating results start from the 4th Century, when the Maya Civilization was at its peak during the Classic Period. Sedimentation rates show a notable increase at the end of the 19th Century. The increase of the sedimentation rates seems to be related to changes in land uses in the Sierra Madre de Chiapas and Altos de Chiapas, based on deforestation and land clearing for developing new agrarian and pastoral activities. We conclude that the major environmental change in the basin of the Usumacinta and Grijalva Rivers since the Maya Classic Period was generated since the last Century as a result of an intense anthropogenic disturbance of mountain rain forest in Chiapas.

  16. Timing of lake-level changes for a deep last-glacial Lake Missoula: optical dating of the Garden Gulch area, Montana, USA

    NASA Astrophysics Data System (ADS)

    Smith, Larry N.; Sohbati, Reza; Buylaert, Jan-Pieter; Lian, Olav B.; Murray, Andrew; Jain, Mayank

    2018-03-01

    Glaciolacustrine sediments in the Clark Fork River valley at Garden Gulch, near Drummond, Montana, USA record highstand positions of the ice-dammed glacial Lake Missoula and repeated subaerial exposure. During these highstands the lake was at greater than 65% of its recognized maximum capacity. The initial lake transgression deposited a basal sand unit. Subsequent cycles of lake-level fluctuations are recorded by sequences of laminated and cross laminated silt, sand, and clay deformed by periglacial processes during intervening periods of lower lake levels. Optically stimulated luminescence (OSL) dating of quartz sand grains, using single-aliquot regenerative-dose procedures, was carried out on 17 samples. Comparison of infrared stimulated luminescence (IRSL) from K-rich feldspar to OSL from quartz for all the samples suggests that they were well bleached prior to deposition and burial. Ages for the basal sand and overlying glaciolacustrine exposure surfaces are indistinguishable within one standard deviation, and give a weighted mean age of 20.9 ± 1.3 ka (n = 11). Based on sedimentological and stratigraphic analysis we infer that the initial transgression, and at least six cycles of lake-level fluctuation, occurred over time scales of decades to ∼2 ka. Bioturbated sandy slopewash dated at 10.6 ± 0.9 ka and 11.9 ± 1.2 ka unconformably overlies the upper glaciolacustrine deposits. The uppermost sediments, above the glaciolacustrine section, are younger than the Glacier Peak tephra (13.7-13.4 cal ka B.P.), which was deposited across parts of the drained lake basin, but has not been found at Garden Gulch. Our study indicates that glacial Lake Missoula reached >65 percent of maximum capacity by about 20.9 ± 1.3 ka and either partially or completely drained twelve times from this position. Rapid lowering from the lake's highstand position due to ice-dam failure likely led to scour in the downstream portions of the glacial Lake Missoula basin and megafloods in the Channeled Scabland.

  17. SU-E-CAMPUS-T-05: Preliminary Results On a 2D Dosimetry System Based On the Optically Stimulated Luminescence of Al2O3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmed, M; Eller, S; Yukihara, E

    2014-06-15

    Purpose: To develop a precise 2D dose mapping technique based on the optically stimulated luminescence (OSL) from Al{sub 2}O{sub 3} films for medical applications. Methods: A 2D laser scanning reader was developed using fast F{sup +}-center (lifetime of <7 ns) and slow F-center (lifetime of 35 ms) OSL emission from newly developed Al{sub 2}O{sub 3} films (Landauer Inc.). An algorithm was developed to correct images for both material and system properties. Since greater contribution of the F??-center emission in the recorded signal increases the readout efficiency and robustness of image corrections, Al{sub 2}O{sub 3}:C,Mg film samples are being investigated inmore » addition to Al{sub 2}O{sub 3}:C samples. Preliminary investigations include exposure of the films to a 6 MV photon beam at 10 cm depth in solid water phantom with an SSD of 100 cm, using a 10 cm × 10 cm flat field or a 4 cm × 4 cm field with a 60° wedge filter. Kodak EDR2 radiographic film and EBT2 Gafchromic film were also exposed for comparison. Results: The results indicate that the algorithm is able to correct images and calculate 2D dose. For the wedge field irradiation, the calculated dose at the center of the field was 0.9 Gy for Al{sub 2}O{sub 3}:C and 0.87 Gy for Al{sub 2}O{sub 3}:C,Mg, whereas, the delivered dose was 0.95 Gy. A good qualitative agreement of the dose profiles was obtained between the OSL films and EDR2 and EBT2 films. Laboratory tests using a beta source suggest that a large dynamic range (10{sup −2}−10{sup 2} Gy) can be achieved using this technique. Conclusion: A 2D dosimetry system and an in-house image correction algorithm were developed for 2D film dosimetry in medical applications. The system is in the preliminary stage of development, but the data demonstrates the feasibility of this approach. This work was supported by Landauer, Inc.« less

  18. The Palaeolithic site Bistricioara-Lut\\varie III in the Romanian Carpathians - Insights from various luminescence methods

    NASA Astrophysics Data System (ADS)

    Schmidt, Christoph; Antohi-Trandafir, Oana; Timar-Gabor, Alida; Anghelinu, Mircea; Veres, Daniel; Hambach, Ulrich

    2016-04-01

    The loess derivates on top of the terrace gravels in the Bistrita valley (Carpathians, northeastern Romania) host a large number of Palaeolithic settlements, some of which reveal several distinct cultural layers characterised by charcoal, other combustion features and/or scattered lithics. While the youngest productive layers at the site Bistricioara-Lut\\varie III (BL III) are associated with Gravettian and Epigravettian technocomplexes, the knowledge about older occupations remains diffuse. Definitely, the high density of last glacial settlements in such a harsh environment represents a puzzle. Furthermore, new excavations in 2015 exposed large (>1 m) combustion features without a related lithic inventory and of unknown origin (natural fires or fires places). The present contribution aims at fathoming the versatile applications of luminescence methods to tackle the unsolved questions at BL III. Despite methodological deficiencies concerning grain size dependent age discrepancies, optically stimulated luminescence (OSL) of quartz demonstrated the archive's chronological depth (>76 ka above terrace gravels) and placed the youngest cultural layer (CL1) in the Last Glacial Maximum, in agreement with radiocarbon (14C) dates (Trandafir et al. 2015). This cultural layer yielded a set of heated lithics (flint) during the recent excavation, providing the opportunity to directly date human presence by thermoluminescence (TL) and to reconcile these ages with (independent) methods dating different events (OSL, 14C). Such a comparison of techniques also serves at testing the accuracy of explorative TL measurement protocols under 'natural conditions'. Finally, detached from any chronological issues, the temperature-dependent sensitisation of the 110 °C quartz TL peak - in analogue to the flint TL signal - potentially allows determining the maximum heating temperature of samples from the combustion features (Göksu et al. 1989), which in turn helps elucidating whether the fires were of natural or anthropogenic origin. References Göksu, H.Y., Weiser, A., Regulla, D.F., 1989. 110 °C TL peak records the ancient heat treatment of flint. Ancient TL 7, 15-17. Trandafir, O., Timar-Gabor, A., Schmidt, C., Veres, D., Anghelinu, M., Hambach, U., Simon, S., 2015. OSL dating of fine and coarse quartz from a Palaeolithic sequence on the Bistrita Valley (Northeastern Romania). Quaternary Geochronology 30, 487-492.

  19. MEASUREMENT OF RADIATION DOSES TO THE EYE LENS DURING ORTHOPEDIC SURGERY USING AN C-ARM X-RAY SYSTEM.

    PubMed

    Suzuki, Akira; Matsubara, Kosuke; Sasa, Yuko

    2018-04-01

    The present study aimed to determine doses delivered to the eye lenses of surgeons while using the inverted-C-arm technique and the protective effect of leaded spectacles during orthopedic surgery. The kerma in air was measured at five positions on leaded glasses positioned near the eye lens and on the neck using small optically stimulated luminescence (OSL) dosemeters. The lens equivalent dose was also measured at the neck using an OSL dosemeter. The maximum equivalent dose to the eye lens and the maximum kerma were 0.8 mSv/month and 0.66 mGy/month, respectively. The leaded glasses reduced the exposure by ~60%. Even if the surgeons are exposed to the maximum dose of X-ray radiation for 5 years, the equivalent doses to the eye lens will not exceed the present limit recommended by the ICRP.

  20. Synthesis and characterization of luminescent materials for thermal sensing and proton dosimetry

    NASA Astrophysics Data System (ADS)

    Doull, Brandon Arthur

    The work presented in this thesis is the materials synthesis, investigation of synthesis parameters, and basic luminescent characterizations of MgB 4O7, Li2B4O7, and MgO for the applications of thermal sensing using thermoluminescence (TL) and proton dosimetry using optically stimulated luminescence (OSL). The materials were synthesized using solution combustion synthesis and characterized by x-ray diffraction, radioluminescence, thermoluminescence, and optically stimulated luminescence. Based upon the basic characterizations MgB 4O7:Li,Dy and Li2B4O7:Cu,Ag were selected for their potential for use as TL materials for thermal sensing while MgB4O7:Li,Ce and MgO:Li were chosen for use as OSL materials in proton dosimetry. Furthermore, MgB4O7:Li,Ce and MgO:Li were fabricated into detector assemblies and exposed to a clinical proton beam for analysis.

  1. Development and validation of a GEANT4 radiation transport code for CT dosimetry

    PubMed Central

    Carver, DE; Kost, SD; Fernald, MJ; Lewis, KG; Fraser, ND; Pickens, DR; Price, RR; Stabin, MG

    2014-01-01

    We have created a radiation transport code using the GEANT4 Monte Carlo toolkit to simulate pediatric patients undergoing CT examinations. The focus of this paper is to validate our simulation with real-world physical dosimetry measurements using two independent techniques. Exposure measurements were made with a standard 100-mm CT pencil ionization chamber, and absorbed doses were also measured using optically stimulated luminescent (OSL) dosimeters. Measurements were made in air, a standard 16-cm acrylic head phantom, and a standard 32-cm acrylic body phantom. Physical dose measurements determined from the ionization chamber in air for 100 and 120 kVp beam energies were used to derive photon-fluence calibration factors. Both ion chamber and OSL measurement results provide useful comparisons in the validation of our Monte Carlo simulations. We found that simulated and measured CTDI values were within an overall average of 6% of each other. PMID:25706135

  2. Study of radiation induced effects in the luminescence of nanostructured Al2O3: Yb, Er crystals

    NASA Astrophysics Data System (ADS)

    Gonçalves, K. A.; Bitencourt, J. F. S.; Mittani, J. C. R.; Tatumi, S. H.

    2010-11-01

    Alumina crystals doped with Yb and Er were obtained by sol gel process and their morphologies and luminescence properties were discussed. Nanocrystals formations composed by Er2O3, Yb2O3 e Yb3Al5O12 were observed by TEM images, EDS, electron beam diffraction and XRD, at the surface of the alumina grains. The size of the nanocrystals were of about (36±2) nm and (182±8) nm for the samples calcinated at 1200oC and 1600oC, respectively. The sample codoped with 1mol% of Er and 2 mol% of Yb supplied the best results for Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL). The growth intensity of dosimetric TL peak at 205oC was linear with gamma radiation doses and the same behavior was observed in OSL results.

  3. Development and validation of a GEANT4 radiation transport code for CT dosimetry.

    PubMed

    Carver, D E; Kost, S D; Fernald, M J; Lewis, K G; Fraser, N D; Pickens, D R; Price, R R; Stabin, M G

    2015-04-01

    The authors have created a radiation transport code using the GEANT4 Monte Carlo toolkit to simulate pediatric patients undergoing CT examinations. The focus of this paper is to validate their simulation with real-world physical dosimetry measurements using two independent techniques. Exposure measurements were made with a standard 100-mm CT pencil ionization chamber, and absorbed doses were also measured using optically stimulated luminescent (OSL) dosimeters. Measurements were made in air with a standard 16-cm acrylic head phantom and with a standard 32-cm acrylic body phantom. Physical dose measurements determined from the ionization chamber in air for 100 and 120 kVp beam energies were used to derive photon-fluence calibration factors. Both ion chamber and OSL measurement results provide useful comparisons in the validation of the Monte Carlo simulations. It was found that simulated and measured CTDI values were within an overall average of 6% of each other.

  4. An optical age chronology of late Quaternary extreme fluvial events recorded in Ugandan dambo soils

    USGS Publications Warehouse

    Mahan, S.A.; Brown, D.J.

    2007-01-01

    There is little geochonological data on sedimentation in dambos (seasonally saturated, channel-less valley floors) found throughout Central and Southern Africa. Radiocarbon dating is problematic for dambos due to (i) oxidation of organic materials during dry seasons; and (ii) the potential for contemporary biological contamination of near-surface sediments. However, for luminescence dating the equatorial site and semi-arid climate facilitate grain bleaching, while the gentle terrain ensures shallow water columns, low turbidity, and relatively long surface exposures for transported grains prior to deposition and burial. For this study, we focused on dating sandy strata (indicative of high-energy fluvial events) at various positions and depths within a second-order dambo in central Uganda. Blue-light quartz optically stimulated luminescences (OSL) ages were compared with infrared stimulated luminescence (IRSL) and thermoluminescence (TL) ages from finer grains in the same sample. A total of 8 samples were dated, with 6 intervals obtained at ???35, 33, 16, 10.4, 8.4, and 5.9 ka. In general, luminescence ages were stratigraphically, geomorphically and ordinally consistent and most blue-light OSL ages could be correlated with well-dated climatic events registered either in Greenland ice cores or Lake Victoria sediments. Based upon OSL age correlations, we theorize that extreme fluvial dambo events occur primarily during relatively wet periods, often preceding humid-to-arid transitions. The optical ages reported in this study provide the first detailed chronology of dambo sedimentation, and we anticipate that further dambo work could provide a wealth of information on the paleohydrology of Central and Southern Africa. ?? 2006 Elsevier Ltd. All rights reserved.

  5. Palaeoclimatic implications of aeolian sediments on the Miaodao Islands, Bohai Sea, East China, based on OSL dating and proxies

    NASA Astrophysics Data System (ADS)

    Xu, Shujian; Ding, Xinchao; Yu, Lupeng; Ni, Zhichao

    2015-12-01

    The loess-paleosol sequences in Shandong Province, East China, is an important aeolian archive, which can provide information for aeolian activity, palaeoclimatic change and sea level change in eastern coast of China since the last interglacial period. However, for so long, most of the studies about loess have been focused on the Chinese Loess Plateau, remaining many questions and disputes about the loess in East China. The Xianjingyuan (XJY) section on the TIA, Bohai Sea, is a representative aeolian section for islands off the eastern coast of China. In this study, optically stimulated luminescence (OSL) dating, particle size and magnetic susceptibility were applied to date and analysis the loess-paleosol sequences in this section. The results show that: (1) The OSL ages at the depths of 0.8 m, 2.5 m, and 3.9 m are 12.6 ± 1.0 ka, 19.2 ± 1.1 ka and 56.9 ± 2.6 ka, respectively, and the loess started to accumulate at ca. 86.5 ka according to the depositional rates (2) The loess accumulated mainly during the Marine Isotope Stage (MIS) 2, i.e., Last glacial maximum and deglaciation, MIS4 and MIS3b with higher depositional rate, coarser grain size, and higher magnetic susceptibility; while paleosol mainly developed during MIS3a, MIS3c and MIS5 with lower depositional rate, finer grain size and lower magnetic susceptibility. (3) The palaeoclimatic changes and aeolian sediments evolution were mainly controlled by the changes of East Asian summer monsoon and sea levels.

  6. Optical dating of eolian deposits since the last interglacial along the northern margin of the Chinese Loess Plateau

    NASA Astrophysics Data System (ADS)

    Lü, Tongyan; Sun, Jimin; Gong, Zhijun

    2018-04-01

    Understanding the chronology of eolian sand-loess-paleosol sequences along the northern margin of the Chinese Loess Plateau (CLP) is crucial for comprehending climate change and the advance and retreat of the adjacent Mu Us desert. In this study, a sand-loess-soil sequence from the northern margin of the CLP was studied by applying the single aliquot regenerative (SAR) protocol to quartz grains, and the multi-elevated-temperature post-IR IRSL (MET-pIRIR) protocol to K-feldspar grains. For equivalent dose (De) determination, 63-90 μm quartz and K-feldspar grains were used. Our results indicate that the MET-pIRIR ages of K-feldspar grains in this sequence range from 94.4 ± 7.0 ka to 148.3 ± 13.3 ka for the last interglacial paleosol (S1); for the upper part of the section, quartz-based SAR-OSL dating was used, yielding ages spanning from 5.8 ± 0.4 ka to 35.9 ± 4.1 ka. After cross-checking these results with previously-reported isochron OSL and TL ages, the reliability of the MET-pIRIR protocol when applied to the last interglacial paleosol was confirmed. Based on a new OSL chronology of the Shimao profile, the studied eolian deposits can be broadly correlated with the last glacial-interglacial cycle, but their dating also points to sedimentary hiatuses occurring at 94.4 ka, 35.9 ka and 5.8 ka, due most probably to strong wind erosion caused by intensified cold-dry winter monsoonal circulations during the last glacial maxima.

  7. The chronology of Late Pleistocene thermal contraction cracking derived from sand wedge OSL dating in central and southern France

    NASA Astrophysics Data System (ADS)

    Andrieux, Eric; Bateman, Mark D.; Bertran, Pascal

    2018-03-01

    Much of France remained unglaciated during the Late Quaternary and was subjected to repeated phases of periglacial activity. Numerous periglacial features have been reported but disentangling the environmental and climatic conditions they formed under, the timing and extent of permafrost and the role of seasonal frost has remained elusive. The primary sandy infillings of relict sand-wedges and composite-wedge pseudomorphs record periglacial activity. As they contain well-bleached quartz-rich aeolian material they are suitable for optically stimulated luminescence dating (OSL). This study aims to reconstruct when wedge activity took place in two regions of France; Northern Aquitaine and in the Loire valley. Results from single-grain OSL measurements identify multiple phases of activity within sand wedges which suggest that wedge activity in France occurred at least 11 times over the last 100 ka. The most widespread events of thermal contraction cracking occurred between ca. 30 and 24 ka (Last Permafrost Maximum) which are concomitant with periods of high sand availability (MIS 2). Although most phases of sand-wedge growth correlate well with known Pleistocene cold periods, the identification of wedge activity during late MIS 5 and the Younger Dryas strongly suggests that these features do not only indicate permafrost but also deep seasonal ground freezing in the context of low winter insolation. These data also suggest that the overall young ages yielded by North-European sand-wedges likely result from poor record of periglacial periods concomitant with low sand availability and/or age averaging inherent with standard luminescence methods.

  8. Organ dose measurements from multiple-detector computed tomography using a commercial dosimetry system and tomographic, physical phantoms

    NASA Astrophysics Data System (ADS)

    Lavoie, Lindsey K.

    The technology of computed tomography (CT) imaging has soared over the last decade with the use of multi-detector CT (MDCT) scanners that are capable of performing studies in a matter of seconds. While the diagnostic information obtained from MDCT imaging is extremely valuable, it is important to ensure that the radiation doses resulting from these studies are at acceptably safe levels. This research project focused on the measurement of organ doses resulting from modern MDCT scanners. A commercially-available dosimetry system was used to measure organ doses. Small dosimeters made of optically-stimulated luminescent (OSL) material were analyzed with a portable OSL reader. Detailed verification of this system was performed. Characteristics studied include energy, scatter, and angular responses; dose linearity, ability to erase the exposed dose and ability to reuse dosimeters multiple times. The results of this verification process were positive. While small correction factors needed to be applied to the dose reported by the OSL reader, these factors were small and expected. Physical, tomographic pediatric and adult phantoms were used to measure organ doses. These phantoms were developed from CT images and are composed of tissue-equivalent materials. Because the adult phantom is comprised of numerous segments, dosimeters were placed in the phantom at several organ locations, and doses to select organs were measured using three clinical protocols: pediatric craniosynostosis, adult brain perfusion and adult cardiac CT angiography (CTA). A wide-beam, 320-slice, volumetric CT scanner and a 64-slice, MDCT scanner were used for organ dose measurements. Doses ranged from 1 to 26 mGy for the pediatric protocol, 1 to 1241 mGy for the brain perfusion protocol, and 2-100 mGy for the cardiac protocol. In most cases, the doses measured on the 64-slice scanner were higher than those on the 320-slice scanner. A methodology to measure organ doses with OSL dosimeters received from CT imaging has been presented. These measurements are especially important in keeping with the ALARA (as low as reasonably achievable) principle. While diagnostic information from CT imaging is valuable and necessary, the dose to patients is always a consideration. This methodology aids in this important task. (Full text of this dissertation may be available via the University of Florida Libraries web site. Please check http://www.uflib.ufl.edu/etd.html)

  9. Development of direct dating methods of fault gouges: Deep drilling into Nojima Fault, Japan

    NASA Astrophysics Data System (ADS)

    Miyawaki, M.; Uchida, J. I.; Satsukawa, T.

    2017-12-01

    It is crucial to develop a direct dating method of fault gouges for the assessment of recent fault activity in terms of site evaluation for nuclear power plants. This method would be useful in regions without Late Pleistocene overlying sediments. In order to estimate the age of the latest fault slip event, it is necessary to use fault gouges which have experienced high frictional heating sufficient for age resetting. It is said that frictional heating is higher in deeper depths, because frictional heating generated by fault movement is determined depending on the shear stress. Therefore, we should determine the reliable depth of age resetting, as it is likely that fault gouges from the ground surface have been dated to be older than the actual age of the latest fault movement due to incomplete resetting. In this project, we target the Nojima fault which triggered the 1995 Kobe earthquake in Japan. Samples are collected from various depths (300-1,500m) by trenching and drilling to investigate age resetting conditions and depth using several methods including electron spin resonance (ESR) and optical stimulated luminescence (OSL), which are applicable to ages later than the Late Pleistocene. The preliminary results by the ESR method show approx. 1.1 Ma1) at the ground surface and 0.15-0.28 Ma2) at 388 m depth, respectively. These results indicate that samples from deeper depths preserve a younger age. In contrast, the OSL method dated approx. 2,200 yr1) at the ground surface. Although further consideration is still needed as there is a large margin of error, this result indicates that the age resetting depth of OSL is relatively shallow due to the high thermosensitivity of OSL compare to ESR. In the future, we plan to carry out further investigation for dating fault gouges from various depths up to approx. 1,500 m to verify the use of these direct dating methods.1) Kyoto University, 2017. FY27 Commissioned for the disaster presentation on nuclear facilities (Drilling borehole survey at the Nojima fault), Technical Report. (in Japanese)2) T. Fukuchi, 2001, Assessment of fault activity by ESR dating of fault gouge; an example of the 500m core samples drilled into the Nojima Earthquake Fault in Japan. Quaternary Science Reviews, 20, 1005-1008.

  10. Chronostratigraphic Analysis of Geomorphic Features within the Former Sinepuxent Inlet: A Wave-Dominated Tidal Inlet along Assateague Island, MD, USA

    NASA Astrophysics Data System (ADS)

    Seminack, C.; McBride, R.; Petruny, L. M.

    2017-12-01

    The former Sinepuxent Inlet, located along the mixed-energy, wave-dominated Assateague Island, MD-VA, USA, contains some of the most robust recurved-spit ridges along the span of the barrier island. In addition, this former tidal inlet exhibits a poorly developed flood-tidal delta containing at least two sets of curvilinear ridges known as "washarounds". Historical maps and nautical charts indicate that the former Sinepuxent Inlet was open from 1755 to 1832. However, previous studies conducted at the former Sinepuxent Inlet hypothesized that the site was exposed to episodic breaching events because of the extensive width of the former inlet throat, constrained by the northern and southern recurved-spit ridges. A total of 16 sediment cores, 10 optically stimulated luminescence (OSL) samples, and three 14C samples (mixed benthic foraminifera and eastern mud snail [Ilyanassa obsolete]) were collected from the former Sinepuxent Inlet to place morphostratigraphic units into a chronological context. Six OSL samples were collected from the northern and southern recurved-spit ridges at mean sea level (MSL) to constrain genesis ages. Southern recurved-spit ages varied more than their northern counterparts, ranging from 1640 to 1990 AD. The northern recurved-spit ridges varied in age from 1770 to 1900 AD. Two OSL samples collected from flood-tidal delta ridges yielded ages from 1680 to 2000 AD. In addition, two 14C samples collected at 128 and 101 cm below MSL within the inlet throat yielded ages between 1720 and post-1950 AD. Ultimately, these dates overlap with the inlet activity phase as indicated in historical documents. Conversely, two OSL samples (155 and 201 cm below MSL) and one 14C sample (134 cm below MSL) collected from the inlet throat returned ages between 760 and 1465 AD. The contrast in ages between the older inlet throat and subaerial ridge samples supports the hypothesis that the former Sinepuxent Inlet was reactivated numerous times. Thus, the three age groupings of geomorphic features (1. older inlet throat, 2. southern recurved-spit ridges & flood-tidal delta ridges, and 3. northern recurved-spit ridges & younger inlet throat) at the former Sinepuxent Inlet likely record the response of Assateague Island to at least three intense storms over the past 1,200 years.

  11. Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies.

    PubMed

    Petibon, Yoann; Rakvongthai, Yothin; El Fakhri, Georges; Ouyang, Jinsong

    2017-05-07

    Dynamic PET myocardial perfusion imaging (MPI) used in conjunction with tracer kinetic modeling enables the quantification of absolute myocardial blood flow (MBF). However, MBF maps computed using the traditional indirect method (i.e. post-reconstruction voxel-wise fitting of kinetic model to PET time-activity-curves-TACs) suffer from poor signal-to-noise ratio (SNR). Direct reconstruction of kinetic parameters from raw PET projection data has been shown to offer parametric images with higher SNR compared to the indirect method. The aim of this study was to extend and evaluate the performance of a direct parametric reconstruction method using in vivo dynamic PET MPI data for the purpose of quantifying MBF. Dynamic PET MPI studies were performed on two healthy pigs using a Siemens Biograph mMR scanner. List-mode PET data for each animal were acquired following a bolus injection of ~7-8 mCi of 18 F-flurpiridaz, a myocardial perfusion agent. Fully-3D dynamic PET sinograms were obtained by sorting the coincidence events into 16 temporal frames covering ~5 min after radiotracer administration. Additionally, eight independent noise realizations of both scans-each containing 1/8th of the total number of events-were generated from the original list-mode data. Dynamic sinograms were then used to compute parametric maps using the conventional indirect method and the proposed direct method. For both methods, a one-tissue compartment model accounting for spillover from the left and right ventricle blood-pools was used to describe the kinetics of 18 F-flurpiridaz. An image-derived arterial input function obtained from a TAC taken in the left ventricle cavity was used for tracer kinetic analysis. For the indirect method, frame-by-frame images were estimated using two fully-3D reconstruction techniques: the standard ordered subset expectation maximization (OSEM) reconstruction algorithm on one side, and the one-step late maximum a posteriori (OSL-MAP) algorithm on the other side, which incorporates a quadratic penalty function. The parametric images were then calculated using voxel-wise weighted least-square fitting of the reconstructed myocardial PET TACs. For the direct method, parametric images were estimated directly from the dynamic PET sinograms using a maximum a posteriori (MAP) parametric reconstruction algorithm which optimizes an objective function comprised of the Poisson log-likelihood term, the kinetic model and a quadratic penalty function. Maximization of the objective function with respect to each set of parameters was achieved using a preconditioned conjugate gradient algorithm with a specifically developed pre-conditioner. The performance of the direct method was evaluated by comparing voxel- and segment-wise estimates of [Formula: see text], the tracer transport rate (ml · min -1 · ml -1 ), to those obtained using the indirect method applied to both OSEM and OSL-MAP dynamic reconstructions. The proposed direct reconstruction method produced [Formula: see text] maps with visibly lower noise than the indirect method based on OSEM and OSL-MAP reconstructions. At normal count levels, the direct method was shown to outperform the indirect method based on OSL-MAP in the sense that at matched level of bias, reduced regional noise levels were obtained. At lower count levels, the direct method produced [Formula: see text] estimates with significantly lower standard deviation across noise realizations than the indirect method based on OSL-MAP at matched bias level. In all cases, the direct method yielded lower noise and standard deviation than the indirect method based on OSEM. Overall, the proposed direct reconstruction offered a better bias-variance tradeoff than the indirect method applied to either OSEM and OSL-MAP. Direct parametric reconstruction as applied to in vivo dynamic PET MPI data is therefore a promising method for producing MBF maps with lower variance.

  12. Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in-vivo studies

    PubMed Central

    Petibon, Yoann; Rakvongthai, Yothin; Fakhri, Georges El; Ouyang, Jinsong

    2017-01-01

    Dynamic PET myocardial perfusion imaging (MPI) used in conjunction with tracer kinetic modeling enables the quantification of absolute myocardial blood flow (MBF). However, MBF maps computed using the traditional indirect method (i.e. post-reconstruction voxel-wise fitting of kinetic model to PET time-activity-curves -TACs) suffer from poor signal-to-noise ratio (SNR). Direct reconstruction of kinetic parameters from raw PET projection data has been shown to offer parametric images with higher SNR compared to the indirect method. The aim of this study was to extend and evaluate the performance of a direct parametric reconstruction method using in-vivo dynamic PET MPI data for the purpose of quantifying MBF. Dynamic PET MPI studies were performed on two healthy pigs using a Siemens Biograph mMR scanner. List-mode PET data for each animal were acquired following a bolus injection of ~7-8 mCi of 18F-flurpiridaz, a myocardial perfusion agent. Fully-3D dynamic PET sinograms were obtained by sorting the coincidence events into 16 temporal frames covering ~5 min after radiotracer administration. Additionally, eight independent noise realizations of both scans - each containing 1/8th of the total number of events - were generated from the original list-mode data. Dynamic sinograms were then used to compute parametric maps using the conventional indirect method and the proposed direct method. For both methods, a one-tissue compartment model accounting for spillover from the left and right ventricle blood-pools was used to describe the kinetics of 18F-flurpiridaz. An image-derived arterial input function obtained from a TAC taken in the left ventricle cavity was used for tracer kinetic analysis. For the indirect method, frame-by-frame images were estimated using two fully-3D reconstruction techniques: the standard Ordered Subset Expectation Maximization (OSEM) reconstruction algorithm on one side, and the One-Step Late Maximum a Posteriori (OSL-MAP) algorithm on the other side, which incorporates a quadratic penalty function. The parametric images were then calculated using voxel-wise weighted least-square fitting of the reconstructed myocardial PET TACs. For the direct method, parametric images were estimated directly from the dynamic PET sinograms using a maximum a posteriori (MAP) parametric reconstruction algorithm which optimizes an objective function comprised of the Poisson log-likelihood term, the kinetic model and a quadratic penalty function. Maximization of the objective function with respect to each set of parameters was achieved using a preconditioned conjugate gradient algorithm with a specifically developed pre-conditioner. The performance of the direct method was evaluated by comparing voxel- and segment-wise estimates of K1, the tracer transport rate (mL.min−1.mL−1), to those obtained using the indirect method applied to both OSEM and OSL-MAP dynamic reconstructions. The proposed direct reconstruction method produced K1 maps with visibly lower noise than the indirect method based on OSEM and OSL-MAP reconstructions. At normal count levels, the direct method was shown to outperform the indirect method based on OSL-MAP in the sense that at matched level of bias, reduced regional noise levels were obtained. At lower count levels, the direct method produced K1 estimates with significantly lower standard deviation across noise realizations than the indirect method based on OSL-MAP at matched bias level. In all cases, the direct method yielded lower noise and standard deviation than the indirect method based on OSEM. Overall, the proposed direct reconstruction offered a better bias-variance tradeoff than the indirect method applied to either OSEM and OSL-MAP. Direct parametric reconstruction as applied to in-vivo dynamic PET MPI data is therefore a promising method for producing MBF maps with lower variance. PMID:28379843

  13. Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies

    NASA Astrophysics Data System (ADS)

    Petibon, Yoann; Rakvongthai, Yothin; El Fakhri, Georges; Ouyang, Jinsong

    2017-05-01

    Dynamic PET myocardial perfusion imaging (MPI) used in conjunction with tracer kinetic modeling enables the quantification of absolute myocardial blood flow (MBF). However, MBF maps computed using the traditional indirect method (i.e. post-reconstruction voxel-wise fitting of kinetic model to PET time-activity-curves-TACs) suffer from poor signal-to-noise ratio (SNR). Direct reconstruction of kinetic parameters from raw PET projection data has been shown to offer parametric images with higher SNR compared to the indirect method. The aim of this study was to extend and evaluate the performance of a direct parametric reconstruction method using in vivo dynamic PET MPI data for the purpose of quantifying MBF. Dynamic PET MPI studies were performed on two healthy pigs using a Siemens Biograph mMR scanner. List-mode PET data for each animal were acquired following a bolus injection of ~7-8 mCi of 18F-flurpiridaz, a myocardial perfusion agent. Fully-3D dynamic PET sinograms were obtained by sorting the coincidence events into 16 temporal frames covering ~5 min after radiotracer administration. Additionally, eight independent noise realizations of both scans—each containing 1/8th of the total number of events—were generated from the original list-mode data. Dynamic sinograms were then used to compute parametric maps using the conventional indirect method and the proposed direct method. For both methods, a one-tissue compartment model accounting for spillover from the left and right ventricle blood-pools was used to describe the kinetics of 18F-flurpiridaz. An image-derived arterial input function obtained from a TAC taken in the left ventricle cavity was used for tracer kinetic analysis. For the indirect method, frame-by-frame images were estimated using two fully-3D reconstruction techniques: the standard ordered subset expectation maximization (OSEM) reconstruction algorithm on one side, and the one-step late maximum a posteriori (OSL-MAP) algorithm on the other side, which incorporates a quadratic penalty function. The parametric images were then calculated using voxel-wise weighted least-square fitting of the reconstructed myocardial PET TACs. For the direct method, parametric images were estimated directly from the dynamic PET sinograms using a maximum a posteriori (MAP) parametric reconstruction algorithm which optimizes an objective function comprised of the Poisson log-likelihood term, the kinetic model and a quadratic penalty function. Maximization of the objective function with respect to each set of parameters was achieved using a preconditioned conjugate gradient algorithm with a specifically developed pre-conditioner. The performance of the direct method was evaluated by comparing voxel- and segment-wise estimates of {{K}1} , the tracer transport rate (ml · min-1 · ml-1), to those obtained using the indirect method applied to both OSEM and OSL-MAP dynamic reconstructions. The proposed direct reconstruction method produced {{K}1} maps with visibly lower noise than the indirect method based on OSEM and OSL-MAP reconstructions. At normal count levels, the direct method was shown to outperform the indirect method based on OSL-MAP in the sense that at matched level of bias, reduced regional noise levels were obtained. At lower count levels, the direct method produced {{K}1} estimates with significantly lower standard deviation across noise realizations than the indirect method based on OSL-MAP at matched bias level. In all cases, the direct method yielded lower noise and standard deviation than the indirect method based on OSEM. Overall, the proposed direct reconstruction offered a better bias-variance tradeoff than the indirect method applied to either OSEM and OSL-MAP. Direct parametric reconstruction as applied to in vivo dynamic PET MPI data is therefore a promising method for producing MBF maps with lower variance.

  14. New data on OSL dating of Early Khalynian deposits of Northern Caspian

    NASA Astrophysics Data System (ADS)

    Sychev, Nikita; Yanina, Tamara; Svitoch, Alexander; Kurbanov, Redzhep; Badyukova, Ekaterina

    2016-04-01

    Ponto-Caspian region is the key region the study of which can provide information about the paleogeographic history of the central Eurasia, particularly revealing the history of the East European Plain, the Caucasus and Central Asia. However, despite the long history of the study, today there is no accepted general stratigraphic scheme of the Caspian Sea. One of the most interesting and important stages of Late Pleistocene history of Caspian is Khalynian transgression which is divided into two major phases: early and ate. In the Caspian lowland Lower Khalynian stage are represented by a unique type of deposit - "chocolate clays". A distinctive feature of these sediments is widely distributed among Lower Khalynian deposits of Northern Caspian and the Volga region. All clay deposits are confined to the diverse origins of depression before-Khalynian relief. Chocolate clays formation consists of facies: mono-clay (typological), layered, sand- and silty-clay (Svitoch, Yanina, 1997). Determining the age of chocolate clays by optically stimulated luminescence (OSL) in our view will allow bettering the understanding of their genesis. Age of chocolate clays of Lower Volga was widely dated using the radiocarbon. However, the existing chronology is controversial, raises a number of issues, primarily due to the material of which are used for dating - thin shells of Caspian mollusks of the Didacna Eichw. genus, which are characterized by a significant isotopic exchange with the enclosing sediments (Arslanov, 2015). Lower Volga region is characterized by very complex geological structure of the Late Pleistocene deposits (alternating continental aeolian, alluvial and slope sediments with marine Caspian deposits of different age). There are many conflicting opinions, not only with respect to paleogeographic features of the area, but also to its precise chronology. The differences in opinion over the age of the individual stages of development of the Caspian Sea (transgressions and regressions) reaches high values (Arslanov, 2015). Therefore in this paper we describe the new OSL-dating results of Khalynian transgression sediments. Two key sections were selected for study: Srednaya Akhtuba and Nizhneye Zaymische. The first section - Srednaya Akhtuba is located in the slope of the ravine, cutting through the marine plain, 1 km above the bridge across the Akhtuba river. Nizhneye Zaymische located in the slope of Volga-Akhtuba valley, cutting through the marine Khalynian plain. For the dating of these deposits we used Risø OSL-reader (provided by Nordic luminescence Lab and DTU), and standard SAR protocol (Murray, 2004). The obtained results characterize 5 equivalent doses of chocolate clays samples. The first date was obtained for the top of the chocolate clay, one for the bottom. Accordingly, two calculated OSL-dates indicate the age of these deposits corresponding to initial stage of the first marine isotope stage (MIS-1). These dates are well correlated with the characteristics of age, obtained by radiocarbon and U-Th methods that show their high reliability. The equivalent dose obtained for chocolate clays of Nizhneye Zaimishce is 43 Gy, radiation dose in Akhtuba sediments was about 3.1 Gy per thousand years. This research was supported by the Russian Science Foundation Project 14-17-00705.

  15. Fine Sediment Residency in Streambeds in Southeastern Australia.

    NASA Astrophysics Data System (ADS)

    Croke, J. C.; Thompson, C. J.; Rhodes, E.

    2007-12-01

    A detailed understanding of channel forming and maintenance processes in streams requires some measurement and/or prediction of bed load transport and sediment mobility. Traditional field based measurements of such processes are often problematic due to the high discharge characteristics of upland streams. In part to compensate for such difficulties, empirical flow competence equations have also been developed to predict armour or bedform stabilising grain mobility. These equations have been applied to individual reaches to predict the entrainment of a threshold grain size and the vertical extent of flushing. In cobble- and boulder-bed channels the threshold grain size relates to the size of the bedform stabilising grains (eg. D84, D90). This then allows some prediction of when transport of the matrix material occurs. The application of Optically Stimulated Luminescence (OSL) dating is considered here as an alternative and innovative way to determine fine sediment residency times in stream beds. Age estimates derived from the technique are used to assist in calibrating sediment entrainment models to specific channel types and hydrological regimes. The results from a one-dimensional HEC-RAS model indicate that recurrence interval floods exceeding bankfull up to 13 years are competent to mobilise the maximum overlying surface grain sizes at the sites. OSL minimum age model results of well bleached quartz in the fine matrix particles are in general agreement with selected competence equation predictions. The apparent long (100-1400y) burial age of most of the mineral quartz suggests that competent flows are not able to flush all subsurface fine-bed material. Maximum bed load exchange (flushing) depth was limited to twice the depth of the overlying D90 grain size. Application of OSL in this study provides important insight into the nature of matrix material storage and flushing in mountain streams.

  16. Towards an Accurate and Precise Chronology for the Colonization of Australia: The Example of Riwi, Kimberley, Western Australia.

    PubMed

    Wood, Rachel; Jacobs, Zenobia; Vannieuwenhuyse, Dorcas; Balme, Jane; O'Connor, Sue; Whitau, Rose

    An extensive series of 44 radiocarbon (14C) and 37 optically stimulated luminescence (OSL) ages have been obtained from the site of Riwi, south central Kimberley (NW Australia). As one of the earliest known Pleistocene sites in Australia, with archaeologically sterile sediment beneath deposits containing occupation, the chronology of the site is important in renewed debates surrounding the colonization of Sahul. Charcoal is preserved throughout the sequence and within multiple discrete hearth features. Prior to 14C dating, charcoal has been pretreated with both acid-base-acid (ABA) and acid base oxidation-stepped combustion (ABOx-SC) methods at multiple laboratories. Ages are consistent between laboratories and also between the two pretreatment methods, suggesting that contamination is easily removed from charcoal at Riwi and the Pleistocene ages are likely to be accurate. Whilst some charcoal samples recovered from outside hearth features are identified as outliers within a Bayesian model, all ages on charcoal within hearth features are consistent with stratigraphy. OSL dating has been undertaken using single quartz grains from the sandy matrix. The majority of samples show De distributions that are well-bleached but that also include evidence for mixing as a result of post-depositional bioturbation of the sediment. The results of the two techniques are compared and evaluated within a Bayesian model. Consistency between the two methods is good, and we demonstrate human occupation at this site from 46.4-44.6 cal kBP (95.4% probability range). Importantly, the lowest archaeological horizon at Riwi is underlain by sterile sediments which have been dated by OSL making it possible to demonstrate the absence of human occupation for between 0.9-5.2 ka (68.2% probability range) prior to occupation.

  17. Towards an Accurate and Precise Chronology for the Colonization of Australia: The Example of Riwi, Kimberley, Western Australia

    PubMed Central

    Balme, Jane; O’Connor, Sue; Whitau, Rose

    2016-01-01

    An extensive series of 44 radiocarbon (14C) and 37 optically stimulated luminescence (OSL) ages have been obtained from the site of Riwi, south central Kimberley (NW Australia). As one of the earliest known Pleistocene sites in Australia, with archaeologically sterile sediment beneath deposits containing occupation, the chronology of the site is important in renewed debates surrounding the colonization of Sahul. Charcoal is preserved throughout the sequence and within multiple discrete hearth features. Prior to 14C dating, charcoal has been pretreated with both acid-base-acid (ABA) and acid base oxidation-stepped combustion (ABOx-SC) methods at multiple laboratories. Ages are consistent between laboratories and also between the two pretreatment methods, suggesting that contamination is easily removed from charcoal at Riwi and the Pleistocene ages are likely to be accurate. Whilst some charcoal samples recovered from outside hearth features are identified as outliers within a Bayesian model, all ages on charcoal within hearth features are consistent with stratigraphy. OSL dating has been undertaken using single quartz grains from the sandy matrix. The majority of samples show De distributions that are well-bleached but that also include evidence for mixing as a result of post-depositional bioturbation of the sediment. The results of the two techniques are compared and evaluated within a Bayesian model. Consistency between the two methods is good, and we demonstrate human occupation at this site from 46.4–44.6 cal kBP (95.4% probability range). Importantly, the lowest archaeological horizon at Riwi is underlain by sterile sediments which have been dated by OSL making it possible to demonstrate the absence of human occupation for between 0.9–5.2 ka (68.2% probability range) prior to occupation. PMID:27655174

  18. Response of Nanodot Optically Stimulated Luminescence Dosimeters to Therapeutic Electron Beams.

    PubMed

    Ponmalar, Y Retna; Manickam, Ravikumar; Sathiyan, S; Ganesh, K M; Arun, R; Godson, Henry Finlay

    2017-01-01

    Response of Al 2 O 3 :C-based nanoDot optically stimulated luminescence (OSL) dosimeter was studied for the dosimetry of 6, 9, 12, 16, and 20 MeV therapeutic electron beams. With reference to ionization chamber, no change in the response was observed with the change in the energy of electron beams for the field size from 6 cm × 6 cm to 25 cm × 25 cm, dose rates from 100 MU/min to 600 MU/min, and the linearity in the response up to 300 cGy. The fading of the transient signal was higher for 20 MeV electron beam than that of 6 MeV electron beam by about 5% as compared to value at 20 min after irradiation. The depletion of OSL signal per readout in 200 successive readouts was also found to change with dose and energy of electron beam from 6 MeV (9% and 12% per readout at 2 and 10 Gy, respectively) to 20 MeV (9% and 16% at 2 and 10 Gy, respectively). The OSL sensitivity changed in the range from 2% to 6% with accumulated doses from 2 to 8 Gy and with electron energy from 6 to 20 MeV, but the sensitivity could be reset using an optical annealing treatment. Although negligible fading for postirradiation storage from 20 min to several months, acceptable precision and linearity in the desired range, and high reproducibility makes nanoDot dosimeters very attractive for the dosimetry of therapeutic electron beams, a note should be made for changes in sensitivity at doses beyond 2 Gy and electron beams energy dependence in reuse, short-term fading, and signal depletion on repeated readout.

  19. Comparison of skin dose measurement using nanoDot® dosimeter and machine readings of radiation dose during cardiac catheterization in children

    PubMed Central

    Balaguru, Duraisamy; Rodriguez, Matthew; Leon, Stephanie; Wagner, Louis K; Beasley, Charles W; Sultzer, Andrew; Numan, Mohammed T

    2018-01-01

    Objectives: Direct measurement of skin dose of radiation for children using optically stimulated luminescence (OSL) technology using nanoDot® (Landauer, Glenwood, IL, USA). Background: Radiation dose is estimated as cumulative air kerma (AK) and dosearea product based on standards established for adult size patients. Body size of pediatric patients who undergo cardiac catheterization for congenital heart disease vary widely from newborn to adolescence. Direct, skindose measurement applying OSL technology may eliminate errors in the estimate. Materials and Methods: The nanoDot® (1 cm × 1 cm × flat plastic cassette) is applied to patient's skin using adhesive tape during cardiac catheterization and radiation skin doses were read within 24 hrs. nanoDot® values were compared to the currently available cumulative AK values estimated and displayed on fluoroscopy monitor. Results: A total of 12 children were studied, aged 4 months to 18 years (median 1.1 years) and weight range 5.3–86 kg (median 8.4 kg). nanoDot® readings ranged from 2.58 mGy to 424.8 mGy (median 84.1 mGy). Cumulative AK ranged from 16.2 mGy to 571.2 mGy (median 171.1 mGy). Linear correlation was noted between nanoDot® values and AK values (R2 = 0.88, R = 0.94). nanoDot® readings were approximately 65% of the estimated cumulative AK estimated using the International Electrotechnical Commission standards. Conclusions: Application of OSL technology using nanoDot® provides an alternative to directly measure fluoroscopic skin dose in children during cardiac catheterization. Our data show that the actual skin dose for children is approximately one-third lower than the AK estimated using international standards for adult size patients. PMID:29440825

  20. Response of Nanodot Optically Stimulated Luminescence Dosimeters to Therapeutic Electron Beams

    PubMed Central

    Ponmalar, Y. Retna; Manickam, Ravikumar; Sathiyan, S.; Ganesh, K. M.; Arun, R.; Godson, Henry Finlay

    2017-01-01

    Response of Al2O3:C-based nanoDot optically stimulated luminescence (OSL) dosimeter was studied for the dosimetry of 6, 9, 12, 16, and 20 MeV therapeutic electron beams. With reference to ionization chamber, no change in the response was observed with the change in the energy of electron beams for the field size from 6 cm × 6 cm to 25 cm × 25 cm, dose rates from 100 MU/min to 600 MU/min, and the linearity in the response up to 300 cGy. The fading of the transient signal was higher for 20 MeV electron beam than that of 6 MeV electron beam by about 5% as compared to value at 20 min after irradiation. The depletion of OSL signal per readout in 200 successive readouts was also found to change with dose and energy of electron beam from 6 MeV (9% and 12% per readout at 2 and 10 Gy, respectively) to 20 MeV (9% and 16% at 2 and 10 Gy, respectively). The OSL sensitivity changed in the range from 2% to 6% with accumulated doses from 2 to 8 Gy and with electron energy from 6 to 20 MeV, but the sensitivity could be reset using an optical annealing treatment. Although negligible fading for postirradiation storage from 20 min to several months, acceptable precision and linearity in the desired range, and high reproducibility makes nanoDot dosimeters very attractive for the dosimetry of therapeutic electron beams, a note should be made for changes in sensitivity at doses beyond 2 Gy and electron beams energy dependence in reuse, short-term fading, and signal depletion on repeated readout. PMID:28405107

  1. Fiber-coupled Luminescence Dosimetry in Therapeutic and Diagnostic Radiology

    NASA Astrophysics Data System (ADS)

    Andersen, Claus E.

    2011-05-01

    Fiber-coupled luminescence dosimetry is an emerging technology with several potentially attractive features of relevance for uses in therapeutic and diagnostic radiology: direct water equivalence (i.e. no significant perturbation of the radiation field in a water phantom or a patient), sub-mm detector size, high dynamic range (below a mGy to several Gy), microsecond time resolution, and absence of electrical wires or other electronics in the dosimeter probe head. Fiber-coupled luminescence dosimetry systems typically consist of one or more small samples of phosphor, e.g. a mg of plastic scintillator, attached to 10-20 m long optical fiber cables of plastic. During irradiation, each dosimeter probe spontaneously emits radioluminescence (RL) in proportion to the dose rate. The luminescence intensity can be detected with photomultiplier tubes, CCD cameras or other highly sensitive photodetectors. Some crystalline phosphors, such as carbon-doped aluminium oxide (Al2O3:C) have the ability to store charge produced in the crystal during irradiation. The stored charge may later be released by fiber-guided laser light under emission of so-called optically stimulated luminescence (OSL). The OSL signal therefore reflects the passively integrated dose. In contrast to thermoluminescence dosimetry, fiber-coupled OSL dosimetry may be performed in vivo while the dosimeter is still in the patient. Within the last few years, several improvements and new applications of these techniques have been published, and the objective of this review is to provide an introduction to this field and to outline some of these new results. Emphasis will be given to applications in medical dosimetry such as in vivo real-time dose verification in brachytherapy and methods aimed for improved quality assurance of linear accelerators.

  2. SU-E-J-11: Measurement of Eye Lens Dose for Varian On-Board Imaging with Different CBCT Acquisition Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deshpande, S; Dhote, D; Kumar, R

    Purpose: To measure actual patient eye lens dose for different cone beam computed tomography (CBCT) acquisition protocol of Varian’s On Board Imagining (OBI) system using Optically Stimulated Luminescence (OSL) dosimeter and study the eye lens dose with patient geometry and distance of isocenter to the eye lens Methods: OSL dosimeter was used to measure eye lens dose of patient. OSL dosimeter was placed on patient forehead center during CBCT image acquisition to measure eye lens dose. For three different cone beam acquisition protocol (standard dose head, low dose head and high quality head) of Varian On-Board Imaging, eye lens dosesmore » were measured. Measured doses were correlated with patient geometry and distance between isocenter to eye lens. Results: Measured eye lens dose for standard dose head was in the range of 1.8 mGy to 3.2 mGy, for high quality head protocol dose was in range of 4.5mGy to 9.9 mGy whereas for low dose head was in the range of 0.3mGy to 0.7mGy. Dose to eye lens is depends upon position of isocenter. For posterioraly located tumor eye lens dose is less. Conclusion: From measured doses it can be concluded that by proper selection of imagining protocol and frequency of imaging, it is possible to restrict the eye lens dose below the new limit set by ICRP. However, undoubted advantages of imaging system should be counter balanced by careful consideration of imaging protocol especially for very intense imaging sequences for Adoptive Radiotherapy or IMRT.« less

  3. The current status of eye lens dose measurement in interventional cardiology personnel in Thailand.

    PubMed

    Krisanachinda, Anchali; Srimahachota, Suphot; Matsubara, Kosuke

    2017-06-01

    Workers involved in interventional cardiology procedures receive high eye lens doses if radiation protection tools are not properly utilized. Currently, there is no suitable method for routine measurement of eye dose. In Thailand, the eye lens equivalent doses in terms of Hp(3) of the interventional cardiologists, nurses, and radiographers participating in interventional cardiology procedures have been measured at 12 centers since 2015 in the pilot study. The optically stimulated luminescence (OSL) dosimeter was used for measurement of the occupational exposure and the eye lens dose of 42 interventional cardiology personnel at King Chulalongkorn Memorial Hospital as one of the pilot centers. For all personnel, it is recommended that a first In Light OSL badge is placed at waist level and under the lead apron for determination of Hp(10); a second badge is placed at the collar for determination of Hp(0.07) and estimation of Hp(3). Nano Dots OSL dosimeter has been used as an eye lens dosimeter for 16 interventional cardiology personnel, both with and without lead-glass eyewear. The mean effective dose at the body, equivalent dose at the collar, and estimated eye lens dose were 0.801, 5.88, and 5.70 mSv per year, respectively. The mean eye lens dose measured by the Nano Dots dosimeter was 8.059 mSv per year on the left eye and 3.552 mSv per year on the right eye. Two of 16 interventional cardiologists received annual eye lens doses on the left side without lead glass that were higher than 20 mSv per year, the new eye lens dose limit as recommended by ICRP with the risk of eye lens opacity and cataract.

  4. Comparison of skin dose measurement using nanoDot® dosimeter and machine readings of radiation dose during cardiac catheterization in children.

    PubMed

    Balaguru, Duraisamy; Rodriguez, Matthew; Leon, Stephanie; Wagner, Louis K; Beasley, Charles W; Sultzer, Andrew; Numan, Mohammed T

    2018-01-01

    Direct measurement of skin dose of radiation for children using optically stimulated luminescence (OSL) technology using nanoDot ® (Landauer, Glenwood, IL, USA). Radiation dose is estimated as cumulative air kerma (AK) and dosearea product based on standards established for adult size patients. Body size of pediatric patients who undergo cardiac catheterization for congenital heart disease vary widely from newborn to adolescence. Direct, skindose measurement applying OSL technology may eliminate errors in the estimate. The nanoDot ® (1 cm × 1 cm × flat plastic cassette) is applied to patient's skin using adhesive tape during cardiac catheterization and radiation skin doses were read within 24 hrs. nanoDot ® values were compared to the currently available cumulative AK values estimated and displayed on fluoroscopy monitor. A total of 12 children were studied, aged 4 months to 18 years (median 1.1 years) and weight range 5.3-86 kg (median 8.4 kg). nanoDot® readings ranged from 2.58 mGy to 424.8 mGy (median 84.1 mGy). Cumulative AK ranged from 16.2 mGy to 571.2 mGy (median 171.1 mGy). Linear correlation was noted between nanoDot® values and AK values ( R 2 = 0.88, R = 0.94). nanoDot® readings were approximately 65% of the estimated cumulative AK estimated using the International Electrotechnical Commission standards. Application of OSL technology using nanoDot® provides an alternative to directly measure fluoroscopic skin dose in children during cardiac catheterization. Our data show that the actual skin dose for children is approximately one-third lower than the AK estimated using international standards for adult size patients.

  5. Using OSL to decipher past soil history in archaeological terraces, Judea Highlands, Israel

    NASA Astrophysics Data System (ADS)

    Porat, Naomi; Gadot, Yuval; Davidovich, Uri; Avni, Yoav; Avni, Gideon; Golan, Dani

    2015-04-01

    Archaeological terraces are the most prominent feature of the agricultural sphere in the hilly landscape throughout the Mediterranean. Using terrace walls for the artificial creation of arable plots of land was a major technological innovation that has completely altered the natural terrain. As such, the dating of these simply built features is of upmost importance. Archaeological excavations and OSL dating of the soil infill of terraces were carried out in three excavation areas at Mt. Eitan in the Judea Highlands, Israel. Previous survey showed that Mt. Eitan was settled continuously at least from the Middle Bronze Age (ca 3800 years ago) and until modern times. The OSL ages shows that all extant terraces were constructed in the past 550-200 years, in the Ottoman period. Older ages are limited only to the base of a few terraces, and they range from the Roman Period (ca 1800 years ago) to Mamluk times (ca 700 years ago). Many of the soil samples contain quartz grains with older ages, indicating incomplete bleaching of the sediment at the time of terrace construction. We used the finite mixture model to find out if there are distinct age clusters to these poorly bleached grains. Analyses were carried out on a compilation of all measured De values (small aliquots) from the entire study area, and for each area separately. Results show that the unbleached grains cluster into only a few periods and highlight four synchronous episodes of terrace building in the past 800 years. The Roman and Early Islamic periods are also represented, even in area where soils with such ages were not found. The unbleached grains preserve older episodes of terrace building no longer represented in the landscape.

  6. Dating of river terraces along Lefthand Creek, western High Plains, Colorado, reveals punctuated incision

    NASA Astrophysics Data System (ADS)

    Foster, Melissa A.; Anderson, Robert S.; Gray, Harrison J.; Mahan, Shannon A.

    2017-10-01

    The response of erosional landscapes to Quaternary climate oscillations is recorded in fluvial terraces whose quantitative interpretation requires numerical ages. We investigate gravel-capped strath terraces along the western edge of Colorado's High Plains to constrain the incision history of this shale-dominated landscape. We use 10Be and 26Al cosmogenic radionuclides (CRNs), optically stimulated luminescence (OSL), and thermally transferred OSL (TT-OSL) to date three strath terraces, all beveled in shale bedrock and then deposited upon by Lefthand Creek, which drains the crystalline core of the Front Range. Our study reveals: (i) a long history (hundreds of thousands of years) of fluvial occupation of the second highest terrace, T2 (Table Mountain), with fluvial abandonment at 92 ± 3 ka; (ii) a brief occupation of a narrow and spatially confined terrace, T3, at 98 ± 7 ka; and (iii) a 10-25 thousand year period of cutting and fluvial occupation of a lower terrace, T4, marked by the deposition of a lower alluvial unit between 59 and 68 ka, followed by deposition of an upper alluvial package at 40 ± 3 ka. In conjunction with other recent CRN studies of strath terraces along the Colorado Front Range (Riihimaki et al., 2006; Dühnforth et al., 2012), our data reveal that long periods of lateral planation and fluvial occupation of strath terraces, sometimes lasting several glacial-interglacial cycles, are punctuated by brief episodes of rapid vertical bedrock incision. These data call into question what a singular terrace age represents, as the strath may be cut at one time (its cutting-age) and the terrace surface may be abandoned at a much later time (its abandonment age), and challenge models of strath terraces that appeal to simple pacing by the glacial-interglacial cycles.

  7. Kontekst stratygraficzny zastosowania różnych odmian metody termoluminescencyjnej w datowaniu lessów z terenu Polski południowo-wschodniej i Ukrainy północno-zachodniej

    NASA Astrophysics Data System (ADS)

    Kusiak, Jarosław

    2008-01-01

    Loess profiles contain a complex but usually incomplete sequence of deposits. In order to chronologically organize deposit layers accessible in different exposures it is necessary to use absolute dating methods. The 14C, TL and OSL methods are widely used for dating of the Upper Pleistocene deposits whereas to older Pleistocene deposits only luminescence methods are applied. Some attempts are made to use the OSL method for dating of the deposits older than the Upper Pleistocene. However, the OSL ages seem to be consistently lower than the TL ages, and also considerably underestimated with reference to stratigraphic interpretation. This fact indicates that the TL method should be used above all. The possibility of TL dating of loesses is connected with their aeolian origin. The obtained TL age should correspond to geological time when mineral grains constituting deposit were exposed to sunlight before deposition. Such exactly condition is met in case of loess deposits. There are many variants of thermoluminescence method because different measuring procedures can be used. Depending on the used procedure, the TL ages obtained for the same sample can be considerably different. The manner of equivalent dose determination is decisive for the obtained TL ages. The factors influencing the value of equivalent dose are presented in this paper. The equivalent dose is determined by comparison of thermoluminescence measured for a given sample with thermoluminescence of the same sample after irradiation in laboratory with known doses of ionizing radiation. The following criteria should be taken into account: size of mineral grains, relation between thermoluminescence and heating temperature, way of reduction of unstable thermoluminescence, and the results of plateau test. The variant of thermoluminescence method used in the TL Laboratory of the Department of Physical Geography and Palaeogeography, Maria Curie-Skłodowska University in Lublin is as follows. The dose rate is determined by gamma spectrometry. The equivalent dose is determined by the total-bleach technique for the 45-63 μm fraction. Blue light obtained using the BG-28 filter is applied. Samples are preheated at 160°C for 3 hours before measurement. Light sum is read as the maximum height of glow curve. The application of such measurement procedure allows reliable dating of climatic episodes recorded in loess deposits not only related to the last glacial but also in older ones.

  8. Potential application of metal nanoparticles for dosimetric systems: Concepts and perspectives

    NASA Astrophysics Data System (ADS)

    Guidelli, Eder José; Baffa, Oswaldo

    2014-11-01

    Metallic nanoparticles increase the delivered dose and consequently enhance tissue radio sensitization during radiation therapy of cancer. The Dose Enhancement Factor (DEF) corresponds to the ratio between the dose deposited on a tissue containing nanoparticles, and the dose deposited on a tissue without nanoparticles. In this sense, we have used electron spin resonance spectroscopy (ESR) to investigate how silver and gold nanoparticles affect the dose deposition in alanine dosimeters, which act as a surrogate of soft tissue. Besides optimizing radiation absorption by the dosimeter, the optical properties of these metal nanoparticles could also improve light emission from materials employed as radiation detectors. Therefore, we have also examined how the plasmonic properties of noble metal nanoparticles could enhance radiation detection using optically stimulated luminescence (OSL) dosimetry. This work will show results on how the use of gold and silver nanoparticles are beneficial for the ESR and OSL dosimetric techniques, and will describe the difficulties we have been facing, the challenges to overcome, and the perspectives.

  9. Evaluation of radiation exposure with Tru-Align intraoral rectangular collimation system using OSL dosimeters.

    PubMed

    Goren, Arthur D; Bonvento, Michael J; Fernandez, Thomas J; Abramovitch, Kenneth; Zhang, Wenjian; Roe, Nadine; Seltzer, Jared; Steinberg, Mitchell; Colosi, Dan C

    2011-03-01

    A pilot study to compare radiation exposure with the Tru-Align rectangular collimation system to round collimation exposures was undertaken. Radiation exposure at various points within the cross sections of the collimators and entrance, intraoral and exit dose measurements were measured using InLight OSL dosimeters. Overall dose reduction with the use of the rectangular collimation system was estimated by taking into account the ratios of collimator openings and the average radiation exposure at the measurement points. Use of the Tru-Align system resulted in an average radiation exposure within the perimeter of the projected outline of the rectangular collimator of 36.1 mR, compared to 148.5 mR with the round collimator. Our calculations indicate a dose reduction by a factor of approximately 3.2 in the case of the Tru-Align system compared to round collimation. The Tru-Align system was easy to use, but in some situations failed to allow Xray coverage of the entire surface of the image receptor, leading to cone cuts.

  10. Photoluminescence, optically stimulated luminescence, and thermoluminescence study of RbMgF3:Eu2+

    NASA Astrophysics Data System (ADS)

    Dotzler, C.; Williams, G. V. M.; Rieser, U.; Robinson, J.

    2009-01-01

    Optically stimulated luminescence (OSL) and thermoluminescence are observed in polycrystalline RbMgF3:Eu2+ after x-ray, γ-ray, or β irradiation. The main electron traps are F-centers but there are other unidentified traps. The main hole traps at room temperature are probably Eu3+ and thermal or optical stimulation leads to electron-hole recombination at the Eu3+ site and Eu2+ emissions arising from P6J to S87/2 and 4f5d(Eg) to S87/2 transitions. We find that some of the electron traps can be emptied by infrared stimulation and all of the electron traps can be emptied by white light stimulation. The OSL dark decay is long and exceeds 5 days for traps that are emptied by white light stimulation after initial infrared bleaching. Our results show that this compound can be used as a radiation dosimeter for intermediate dose levels where the R87b self-dose does not significantly affect the dose reading.

  11. TL and OSL dose response of LiF:Mg,Ti and Al2O3:C dosimeters using a PMMA phantom for IMRT technique quality assurance.

    PubMed

    Matsushima, Luciana C; Veneziani, Glauco R; Sakuraba, Roberto K; Cruz, José C; Campos, Letícia L

    2015-06-01

    The principle of IMRT is to treat a patient from a number of different directions (or continuous arcs) with beams of nonuniform fluences, which have been optimized to deliver a high dose to the target volume and an acceptably low dose to the surrounding normal structures (Khan, 2010). This study intends to provide information to the physicist regarding the application of different dosimeters type, phantoms and analysis technique for Intensity Modulated Radiation Therapy (IMRT) dose distributions evaluation. The measures were performed using dosimeters of LiF:Mg,Ti and Al2O3:C evaluated by techniques of thermoluminescent (TL) and Optically Stimulated Luminescence (OSL). A polymethylmethacrylate (PMMA) phantom with five cavities, two principal target volumes considered like tumours to be treated and other three cavities to measure the scattered radiation dose was developed to carried out the measures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Desert agricultural terrace systems at EBA Jawa (Jordan) - Layout, water availability and efficiency

    NASA Astrophysics Data System (ADS)

    Meister, Julia; Krause, Jan; Müller-Neuhof, Bernd; Portillo, Marta; Reimann, Tony; Schütt, Brigitta

    2016-04-01

    Located in the arid basalt desert of northeastern Jordan, the Early Bronze Age (EBA) settlement of Jawa is by far the largest and best preserved archaeological EBA site in the region. Recent surveys in the close vicinity revealed well-preserved remains of three abandoned agricultural terrace systems. In the presented study these archaeological features are documented by detailed mapping and the analysis of the sediment records in a multi-proxy approach. To study the chronology of the terrace systems optically stimulated luminescence (OSL) is used. In order to evaluate the efficiency of the water management techniques and its impact on harvest yields, a crop simulation model (CropSyst) under today's climatic conditions is applied, simulating crop yields with and without (runoff) irrigation. In order to do so, a runoff time series for each agricultural terrace system and its catchment is generated, applying the SCS runoff curve number method (CN) based on rainfall and soil data. Covering a total area of 38 ha, irrigated terrace agriculture was practiced on slopes, small plateaus, and valleys in the close vicinity of Jawa. Floodwater from nearby wadis or runoff from adjacent slopes was collected and diverted via surface canals. The terraced fields were arranged in cascades, allowing effective water exploitation through a system of risers, canals and spillways. The examined terrace profiles show similar stratigraphic sequences of mixed unstratified fine sediments that are composed of small-scale relocated sediments with local origin. The accumulation of these fines is associated with the construction of agricultural terraces, forcing infiltration and storage of the water within the terraces. Two OSL ages of terrace fills indicate that the construction of these terrace systems started as early as 5300 ± 300 a, which fits well to the beginning of the occupation phase of Jawa at around 3.500 calBC, thus making them to the oldest examples of its kind in the Middle East known to date. The results for simulating yields of different crops and under different irrigation scenarios showed that simulated mean grain yields were greater under supplemental irrigation. Thereby, yields usually increase considerably with increasing catchment size and thus (runoff) irrigation. Moreover, there is a significant decrease of crop failures under irrigation. Overall, these agricultural terrace systems seem to have been very efficient and their construction required a good understanding of the local climate, hydrology, geomorphology & pedology.

  13. East Europe Report, Scientific Affairs, Number 749

    DTIC Science & Technology

    1982-07-23

    Scientific Associate A. Andreev, Corresponding Member D. Shopov , Scientific Associate B. Kunev, V. Idakiev and A. Bankova. A collective at the Economic...operational systems — manual, automatic and remote control; control system — G P oSL ?nP™ y measurement ~ automatic and in percentage figures; power

  14. New age estimations for the western outer city wall of ancient Tayma (NW Saudi Arabia) based on OSL and radiocarbon data and geomorphologic evidence

    NASA Astrophysics Data System (ADS)

    Engel, M.; Klasen, N.; Brückner, H.; Eichmann, R.; Hausleiter, A.; Al-Najem, M. H.; Al-Said, S. F.; Schneider, P. I.

    2009-04-01

    Since 2004 tremendous progress has been achieved in deciphering the cultural genesis of the Tayma oasis (NW Saudi Arabia), due to the joint investigations of the German Archaeological Institute Berlin (DAI), the General Commission for Tourism and Antiquities, Kingdom of Saudi Arabia, and the Department of Archaeology and Epigraphy, King Saud University Riyadh. Nevertheless, archaeological research is still suffering from a lacking locally-based absolute chronology of buildings. The pattern of ancient constructions at Tayma is dominated by a prominent city wall system surrounding the ancient town center (Qraya) and stretching 15 km around the oasis. Its internal structure indicates several building periods, i.e. phases of wall modification or extension of the entire system. So far, according to silex and carnelian fragments included in the mud bricks and a previous 14C age of charcoal remains from the central excavation district (wall section at Area A), an initial construction date of the wall between the late 3rd and the early 2nd millennium BC seemed likely. At the excavated western outer city wall a new systematic dating approach - combining the optically stimulated luminescence (OSL) and 14C methods - has been applied to generate a reliable age for the oldest branch of the wall system which nowadays is covered by aeolian sand. The dune deposit is genetically related to the existence of the wall and, therefore, dating its accumulation provides termini ante quem for the construction of the wall. Five OSL dates were generated from the dune deposit providing ages between 4,900 and 3,500 yrs. Two radiocarbon ages support the dating sequence and also contribute to its consistency. By combining the results with geomorphologic evidence we draw the following conclusions: Initial settlement activities at Qraya were accompanied by a regulation of wadi dynamics and the construction of the outer city wall, indicated by the abrupt boundary between the pre-settlement alluvial silt and the overlying wall-related dune deposit. According to the OSL and 14C dating results from this deposit, the wall section at C1 (western part of the ancient settlement, north of Area A) dates back to the middle of the 3rd millennium BC or even earlier. Furthermore, the burying of the still existing remains of the city wall at C1 by sand was already completed at the beginning of the 2nd millennium BC.

  15. Update in diagnosis and management of primary aldosteronism.

    PubMed

    Dick, Sofia M; Queiroz, Marina; Bernardi, Bárbara L; Dall'Agnol, Angélica; Brondani, Letícia A; Silveiro, Sandra P

    2018-02-23

    Primary aldosteronism (PA) is a group of disorders in which aldosterone is excessively produced. These disorders can lead to hypertension, hypokalemia, hypervolemia and metabolic alkalosis. The prevalence of PA ranges from 5% to 12% around the globe, and the most common causes are adrenal adenoma and adrenal hyperplasia. The importance of PA recognition arises from the fact that it can have a remarkably adverse cardiovascular and renal impact, which can even result in death. The aldosterone-to-renin ratio (ARR) is the election test for screening PA, and one of the confirmatory tests, such as oral sodium loading (OSL) or saline infusion test (SIT), is in general necessary to confirm the diagnosis. The distinction between adrenal hyperplasia (AH) or aldosterone-producing adenoma (APA) is essential to select the appropriate treatment. Therefore, in order to identify the subtype of PA, imaging exams such as computed tomography or magnetic ressonance imaging, and/or invasive investigation such as adrenal catheterization must be performed. According to the subtype of PA, optimal treatment - surgical for APA or pharmacological for AH, with drugs like spironolactone and amiloride - must be offered.

  16. Fading test using the SAAD-POSL method for retrospective accidental dosimetry of building materials

    NASA Astrophysics Data System (ADS)

    Kim, M. J.; Lee, Y. J.; Lee, J. I.; Kim, J. L.; Hong, D. G.

    2015-11-01

    Fading test using the single aliquot additive dose method with pulsed optically stimulated luminescence (SAAD-POSL method) was applied to core-disc samples extracted from heated red brick, tile, roof-tile, and toilet porcelain after X-ray and beta irradiation. From thermoluminescence measurements of each material, the optimal preheat condition of the SAAD-POSL method was first determined as 170 °C for 10 s. Fading characteristics of core-disc samples of heated red brick obtained using the SAAD-POSL method were similar to those of quartz grains (90-250 μm) obtained using the SAR-OSL method, regardless of the differences in the sample and radiation type. Fading evaluations of the core-disc samples of these building materials two weeks after irradiation showed that the equivalent dose (ED) decreased between 5% and 42%. The results indicate that the fading characteristics will be able to contribute to a more accurate estimation of the ED value using the SAAD-POSL method.

  17. Developing a Tool for the Location Optimization of the Alert Aircraft with Changing Threat Anticipation

    DTIC Science & Technology

    2009-03-01

    encountered. From individuals to large industries , people deal with such problems in order to maximize the benefit and gain. Third, the effect of the...Format”. http://www.cenapad.unicamp.br/ parque /manuais/OSL/oslweb/features/featur11.htm 17 December 2008 Chhajed, Dilip, Richard L. Francis, and

  18. Cathodoluminescence and Thermoluminescence of Undoped LTB and LTB:A (A = Cu, Ag, Mn)

    DTIC Science & Technology

    2013-03-01

    operated, tabletop instrument for thermoluminescent dosimetry (TLD) measurements seen in Figure 3-8. It reads one dosimeter per loading and...the more sophisticated Riso TL/ OSL reader that Brant used at the University of Cincinnati [9]. Figure 4-12: TL data for LTB: Ag irradiated with 5

  19. Open Simulation Laboratories [Guest editors' introduction

    DOE PAGES

    Alexander, Francis J.; Meneveau, Charles

    2015-09-01

    The introduction for the special issue on open simulation laboratories, the guest editors describe how OSLs will become more common as their potential is better understood and they begin providing access to valuable datasets to much larger segments of the scientific community. Moreover, new analysis tools and ways to do science will inevitably develop as a result.

  20. The responses of three kinds of passive dosimeters to secondary cosmic rays in the lower atmosphere.

    PubMed

    Yang, Zhen; Chen, Bo; Zhuo, Weihai; Fan, Dunhuang; Zhao, Chao; Zhang, Yu

    2015-12-01

    For accurate measurements of the secondary cosmic rays by using passive dosimeters, the relative responses of the thermoluminescence dosimeter (TLD), optically stimulated luminescence (OSL) dosimeter, and radiophotoluminescent glass dosimeter (RPLGD) were studied. The cosmic-ray shower generator was used to simulate the secondary cosmic rays at the sea level. Monte Carlo simulations were performed to calculate the air kerma and absorbed doses in each kind of dosimeter. The results showed that compared with their responses to gamma rays of (137)Cs, the relative responses of the TLD, OSL, and RPLGD were 0.786, 0.707, and 0.735 to the hard component of cosmic rays, respectively, and the values were 0.904, 0.838, and 0.857 to the soft component of cosmic rays, respectively. To verify the simulations results, an in situ measurement with the three kinds of dosimeters was performed at the same place. The results indicated that the secondary cosmic rays monitored with the three kinds of dosimeters were well consistent with each other provided their relative responses were taken into account.

  1. Optically- and thermally-stimulated luminescences of Ce-doped SiO2 glasses prepared by spark plasma sintering

    NASA Astrophysics Data System (ADS)

    Okada, Go; Kasap, Safa; Yanagida, Takayuki

    2016-11-01

    Rare-earth doped phosphors have been used in many applications including radiation measurements. In the latter applications, the radiation photons are converted to light so that we can indirectly detect the radiation using a conventional photodetector. In this work, we have prepared and characterized a Ce-doped SiO2 glass for dosimeter applications. Unlike conventional techniques such as sol-gel synthesis, the sample was prepared by spark plasma sintering. Although the PL emission seems to be only from the Ce3+ ions in the structure, due to the X-ray induced luminescence, we have also observed optically-stimulated luminescence (OSL), and thermally-stimulated luminescence (TSL), owing to a pair of silylenes and a set of dioxasilirane and silylene in addition to Ce3+. We have measured the detector response vs irradiation dose for both the OSL and TSL. The detector response in both cases is linear over the dose range from at least 1 mGy to 2 Gy. Particularly, the sensitivity of TSL is so high that it should be considered to be a good candidate for practical applications.

  2. The responses of three kinds of passive dosimeters to secondary cosmic rays in the lower atmosphere

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Zhen; Chen, Bo, E-mail: bochenfys@fudan.edu.cn; Zhuo, Weihai

    For accurate measurements of the secondary cosmic rays by using passive dosimeters, the relative responses of the thermoluminescence dosimeter (TLD), optically stimulated luminescence (OSL) dosimeter, and radiophotoluminescent glass dosimeter (RPLGD) were studied. The cosmic-ray shower generator was used to simulate the secondary cosmic rays at the sea level. Monte Carlo simulations were performed to calculate the air kerma and absorbed doses in each kind of dosimeter. The results showed that compared with their responses to gamma rays of {sup 137}Cs, the relative responses of the TLD, OSL, and RPLGD were 0.786, 0.707, and 0.735 to the hard component of cosmicmore » rays, respectively, and the values were 0.904, 0.838, and 0.857 to the soft component of cosmic rays, respectively. To verify the simulations results, an in situ measurement with the three kinds of dosimeters was performed at the same place. The results indicated that the secondary cosmic rays monitored with the three kinds of dosimeters were well consistent with each other provided their relative responses were taken into account.« less

  3. Athermal fading of luminescence in Al2 O3 ceramic substrates

    NASA Astrophysics Data System (ADS)

    Terry, Ian; Kouroukla, Eftychia; Bailiff, Ian K.

    2015-03-01

    Retrospective dosimetry aims to reconstruct ionising radiation dose to populations following a radiological incident using materials not designed for that purpose. Sintered alumina ceramic can function as a dosimeter with its luminescence properties and related trapped charge storage mechanism. Its widespread use as a substrate in surface mount devices and incorporation in devices such as mobile phones make it a ubiquitous potential dosimeter. We investigated the optically (OSL) and thermally (TL) stimulated luminescence properties of sintered alumina substrates. In contrast to their single crystal analogue developed for personal dosimetry, Al2O3:C, the substrates exhibit a significant loss of trapped charge (fading) within hours following irradiation at RT that seriously limits their utility for dosimetry over an extended timescale. The fading rates of OSL and TL signals of 0402 resistors were analysed under various storage conditions (time and temperature), complemented by a study of their microstructure. The results support a model of athermal loss of trapped charge due to electron tunnelling from trapping states; this contrasting behaviour is attributed to a physical modification of the trap environment arising from the manufacturing process.

  4. The responses of three kinds of passive dosimeters to secondary cosmic rays in the lower atmosphere

    NASA Astrophysics Data System (ADS)

    Yang, Zhen; Chen, Bo; Zhuo, Weihai; Fan, Dunhuang; Zhao, Chao; Zhang, Yu

    2015-12-01

    For accurate measurements of the secondary cosmic rays by using passive dosimeters, the relative responses of the thermoluminescence dosimeter (TLD), optically stimulated luminescence (OSL) dosimeter, and radiophotoluminescent glass dosimeter (RPLGD) were studied. The cosmic-ray shower generator was used to simulate the secondary cosmic rays at the sea level. Monte Carlo simulations were performed to calculate the air kerma and absorbed doses in each kind of dosimeter. The results showed that compared with their responses to gamma rays of 137Cs, the relative responses of the TLD, OSL, and RPLGD were 0.786, 0.707, and 0.735 to the hard component of cosmic rays, respectively, and the values were 0.904, 0.838, and 0.857 to the soft component of cosmic rays, respectively. To verify the simulations results, an in situ measurement with the three kinds of dosimeters was performed at the same place. The results indicated that the secondary cosmic rays monitored with the three kinds of dosimeters were well consistent with each other provided their relative responses were taken into account.

  5. The R package 'RLumModel': Simulating charge transfer in quartz

    NASA Astrophysics Data System (ADS)

    Friedrich, Johannes; Kreutzer, Sebastian; Schmidt, Christoph

    2017-04-01

    Kinetic models of quartz luminescence have gained an important role for predicting experimental results and for understanding charge transfers in (natural) quartz as well as for other dosimetric materials, e.g., Al2O3:C. We present the R package 'RLumModel', offering an easy-to-use tool for simulating quartz luminescence signals (TL, OSL, LM-OSL and RF) based on five integrated and published parameter sets as well as the possibility to use own parameters. Simulation commands can be created (a) using the Risø Sequence Editor, (b) a built-in SAR sequence generator or (c) self-explanatory keywords for customised sequences. Results can be analysed seamlessly using the R package 'Luminescence' along with a visualisation of concentrations of electrons and holes in every trap/centre as well as in the valence and conduction band during all stages of the simulation. Modelling luminescence signals can help understanding charge transfer processes occurring in nature or during measurements in the laboratory. This will lead to a better understanding of several processes concerning geoscientific questions, because quartz is the second most abundant mineral in the Earth's continental crust.

  6. Rapid and cyclic dust accumulation during MIS 2 in Central Asia inferred from loess OSL dating and grain-size analysis.

    PubMed

    Li, Yun; Song, Yougui; Lai, Zhongping; Han, Li; An, Zhisheng

    2016-09-02

    Due to lack of reliable proxies from the Westerlies-dominant region, the strength change of Northern Hemisphere Westerlies remains poorly understood. The aim of this study is to provide a reliable paleoclimatic proxy about the Northern Hemisphere Westerlies change. Here we report a 30.7 m thick loess section from the Ili basin directly controlled by the Westerlies. Based on optically stimulated luminescence (OSL) and high resolution grain-size records, we reconstruct the change history of the Westerlies strength during the last glacial period (mainly Marine Isotope Stages 2, MIS2), being similar with the Westerlies index recorded in the Qinghai Lake sediments. Within error limits, all ages are in stratigraphic order. We further compare the climatic records among the Ili loess, Qinghai Lake and the NGRIP, their similarity shows a good climatic coupling relationship among the Central Asia, East Asia and the North Atlantic, and the Westerlies plays a critical influence in transporting the North Atlantic signal to Central and East Asia.

  7. Constraining Big Hurricanes: Remotely sensing Galveston Islands' changing coastal landscape from days to millennia

    NASA Astrophysics Data System (ADS)

    Dougherty, A. J.; Choi, J. H.; Heo, S.; Dosseto, A.

    2017-12-01

    Climate change models forecast increased storm intensity, which will drive coastal erosion as sea-level rise accelerates with global warming. Over the last five years the largest hurricanes ever recorded in the Pacific (Patricia) and the Atlantic (Irma) occurred as well as the devastation of Harvey. The preceding decade was marked with Super Storm Sandy, Katrina and Ike. A century prior, the deadliest natural disaster in North America occurred as a category 4 hurricane known as `The 1900 Storm' hit Galveston Island. This research aims to contextualize the impact of storms long before infrastructure and historical/scientific accounts documented erosion. Unlike the majority of barrier islands in the US, Galveston built seaward over the Holocene. As the beach prograded it preserved a history of storms and shoreline change over millennia to the present-day. These systems (called prograded barriers) were first studied over 50 years ago using topographic profiles, sediment cores and radiocarbon dating. This research revisits some of these benchmark study sites to augment existing data utilizing state-of-the-art Light Detection and Ranging (LiDAR), Ground Penetrating Radar (GPR), and Optically Stimulated Luminescence (OSL) techniques. In 2016 GPR and OSL data were collected from Galveston Island, with the aim to combine GPR, OSL and LiDAR (GOaL) to extract a high-resolution geologic record spanning 6,000 years. The resulting millennia-scale coastal evolution can be used to contextualize the impact of historic hurricanes over the past century (`The 1900 Storm'), decade (Ike in 2008) and year (now with Harvey). Preliminary results reveal a recent change in shoreline behaviour, and data from Harvey are currently being accessed within the perspective of these initial findings. This dataset will be discussed with respect to the other two benchmark prograded barriers studied in North America: Nayarit Barrier (Mexico) that Hurricane Patricia passed directly over in 2013 and Kiawah Barrier (South Carolina), which was ultimately spared from Hurricane Irma 2017.

  8. An integrated OSL chronology, sedimentology and geochemical approach to loess deposits from Tuoji Island, Shandong Province: Implications for the late quaternary paleoenvironment in East China

    NASA Astrophysics Data System (ADS)

    Xu, Shujian; Kong, Fanbiao; Jia, Guangju; Miao, Xiaodong; Ding, Xinchao

    2018-04-01

    The Tuoji II (TJII) section on the Miaodao Islands in the Bohai Sea is a representative aeolian section off China's east coast. This study applied optically stimulated luminescence (OSL) dating, conducted grain size analysis, and examined major and trace element compositions, to investigate the loess-paleosol sequences. The OSL ages at depths of 0.6, 1.8, 2.8, 3.8, and 4.8 m were determined as 14.4 ± 0.4, 16.7 ± 1.3, 20.8 ± 1.0, 40.9 ± 1.5, and 47.9 ± 3.7 ka, respectively. It was projected that the loess started to accumulate at ca. 62.6 ka, according to presumed depositional rates. In this study, typical aeolian deposits elsewhere including the Luochuan (LC), Xiashu (XS), Wushan (WS), and Xifeng (XF) sections were compared with TJII section here. The results showed similarity in the geochemical characteristics of the deposits from the different areas of China and normalized upper continental crust, indicating aeolian origin of this island loess. In comparison with the LC, XS, WS, and XF samples, the aeolian deposits of the TJII section have higher concentrations of TiO2 and Zr and lower concentrations of Al2O3, Rb, and Ni, and they have higher SiO2/Al2O3 and TiO2/Al2O3 ratios and lower Al2O3/Na2O and Ba/Sr ratios. These features indicate the dust materials of the TJII section were derived from local sources of well-mixed sedimentary protoliths. Our results support the suggestion that paleoclimatic change and the evolution of aeolian sediments were controlled primarily by variation of the East Asian summer monsoon and sea level change.

  9. Development of an objective dose distribution analysis method for OSL dating and pilot studies for planetary applications

    NASA Astrophysics Data System (ADS)

    Lepper, Kenneth Errol

    Scope and method of study. Part I: In its simplest expression a luminescence age is the natural absorbed radiation dose (De) divided by the in-situ dose rate. The experimental techniques of Optically Stimulated Luminescence (OSL) dating have evolved to the point were hundreds of Des, and therefore depositional ages can be quickly and conveniently determined for a single sediment sample. The first major objective of this research was to develop an objective analysis method for analyzing dose distribution data and selecting an age-representative dose (Dp). The analytical method was developed based on dose data sets collected from 3 eolian and 3 fluvial sediment samples from Central Oklahoma. Findings and conclusions. Part I: An objective method of presenting the dose distribution data, and a mathematically rigorous means of determining the Dp, as well as a statistically meaningful definition of the uncertainty in Dp have been proposed. The concept of experimental error deconvolution was introduced. In addition a set of distribution shape parameters to facilitate comparison among samples have been defined. These analytical techniques hold the potential to greatly enhance the accuracy and utility of OSL dating for young fluvial sediments. Scope and method of study. Part II: The second major objective of this research was to propose the application of luminescence dating to sediments on Mars. A set of fundamental luminescence dating properties was evaluated for a martian surface materials analog and a polar deposit contextual analog. Findings and conclusions. Part II: The luminescence signals measured from the analogs were found to have a wide dynamic dose response range with no unusual or prohibitive short-term instabilities and were readily reset by exposure to sunlight. These properties form a stable base for continued investigations toward the development of luminescence dating instruments and procedures for Mars.

  10. Quaternary alluvial fans of Ciudad Juárez, Chihuahua, northern México: OSL ages and implications for climatic history of the region

    USGS Publications Warehouse

    Zúñiga de León, David; Kershaw, Stephen; Mahan, Shannon

    2016-01-01

    Alluvial fans formed from sediments derived from erosion of the Juárez Mountains in northernmost México have a significant flood impact on the Ciudad Juárez, which is built on the fan system. The northern part of Ciudad Juárez is the most active; further south, older parts of the fan, upon which the rest of the city is built, were largely eroded by natural processes prior to human habitation and subsequently modified only recently by human construction. Three aeolian sand samples, collected from the uppermost (youngest) parts of the fan system in the city area, in places where human intervention has not disturbed the sediment, and constrain the latest dates of fan building. Depositional ages of the Quaternary alluvial fans were measured using Optically Stimulated Luminescence (OSL) on aeolian sands that have inter-fingered with alluvial fan material. These dates are: a) sample P1, 31 ka; b) sample P2, 41 ka; c) sample P3, 74 ka, between Oxygen Isotope Stages (OIS) 3 to 5. They demonstrate that fan development, in the area now occupied by the city, terminated in the Late Pleistocene, immediately after what we interpret to have been an extended period of erosion without further deposition, lasting from the Late Pleistocene to Holocene. The three dates broadly correspond to global glacial periods, implying that the cool, dry periods may reflect periods of aeolian transport in northern México in between phases that were wetter to form the alluvial fans. Alluvial fan margins inter-finger with fluvial terrace sediments derived from the Río Bravo, indicating an additional component of fan dissection by Río Bravo lateral erosion, presumed to be active during earlier times than our OSL ages, but these are not yet dated. Further dating is required to ascertain the controls on the fan and fluvial system.

  11. Evaluation of external exposures of the population of Ozyorsk, Russia, with luminescence measurements of bricks.

    PubMed

    Woda, Clemens; Jacob, P; Ulanovsky, A; Fiedler, I; Mokrov, Y; Rovny, S

    2009-11-01

    Recently discovered historical documents indicate that large releases of noble gases (mainly (41)Ar and radioactive isotopes of Kr and Xe) from the Mayak Production Association (MPA) over the period from 1948 to 1956 may have caused considerable external exposures of both, inhabitants of Ozyorsk and former inhabitants of villages at the upper Techa River. To quantify this exposure, seven brick samples from three buildings in Ozyorsk, located 8-10 km north-northwest from the radioactive gas release points, were taken. The absorbed dose in brick was measured in a depth interval of 3-13 mm below the exposed surface of the bricks by means of the thermoluminescence (TL) and the optically stimulated luminescence (OSL) method. Generally, luminescence properties using TL were more favorable for precise dose determination than using OSL, but within their uncertainties the results from both methods agree well with each other. The absorbed dose due to natural radiation was assessed and subtracted under the assumption of the bricks to be completely dry. The weighted average of the anthropogenic dose for all samples measured by TL and OSL is 10 +/- 9 and 1 +/- 9 mGy, respectively. An upper limit for a possible anthropogenic dose in brick that would not be detected due to the measurement uncertainties is estimated at 24 mGy. This corresponds to an effective dose of about 21 mSv. A similar range of values is obtained in recently published dispersion calculations that were based on reconstructed MPA releases. It is concluded that the release of radioactive noble gases from the radiochemical and reactor plants at Mayak PA did not lead to a significant external exposure of the population of Ozyorsk. In addition, the study demonstrates the detection limit for anthropogenic doses in ca. 60-year-old bricks to be about 24 mGy, if luminescence methods are used.

  12. Dating of river terraces along Lefthand Creek, western High Plains, Colorado, reveals punctuated incision

    USGS Publications Warehouse

    Foster, Melissa A.; Anderson, Robert S.; Gray, Harrison J.; Mahan, Shannon

    2017-01-01

    The response of erosional landscapes to Quaternary climate oscillations is recorded in fluvial terraces whose quantitative interpretation requires numerical ages. We investigate gravel-capped strath terraces along the western edge of Colorado's High Plains to constrain the incision history of this shale-dominated landscape. We use ¹⁰Be and ²⁶Al cosmogenic radionuclides (CRNs), optically stimulated luminescence (OSL), and thermally transferred OSL (TT-OSL) to date three strath terraces, all beveled in shale bedrock and then deposited upon by Lefthand Creek, which drains the crystalline core of the Front Range. Our study reveals: (i) a long history (hundreds of thousands of years) of fluvial occupation of the second highest terrace, T2 (Table Mountain), with fluvial abandonment at 92 ± 3 ka; (ii) a brief occupation of a narrow and spatially confined terrace, T3, at 98 ± 7 ka; and (iii) a 10–25 thousand year period of cutting and fluvial occupation of a lower terrace, T4, marked by the deposition of a lower alluvial unit between 59 and 68 ka, followed by deposition of an upper alluvial package at 40 ± 3 ka. In conjunction with other recent CRN studies of strath terraces along the Colorado Front Range (Riihimaki et al., 2006; Dühnforth et al., 2012), our data reveal that long periods of lateral planation and fluvial occupation of strath terraces, sometimes lasting several glacial-interglacial cycles, are punctuated by brief episodes of rapid vertical bedrock incision. These data call into question what a singular terrace age represents, as the strath may be cut at one time (its cutting-age) and the terrace surface may be abandoned at a much later time (its abandonment age), and challenge models of strath terraces that appeal to simple pacing by the glacial-interglacial cycles.

  13. Commissioning optically stimulated luminescence in vivo dosimeters for fast neutron therapy.

    PubMed

    Young, Lori A; Yang, Fei; Woodworth, Davis; McCormick, Zephyr; Sandison, George

    2016-01-01

    Clinical in vivo dosimeters intended for use with photon and electron therapies have not been utilized for fast neutron therapy because they are highly susceptible to neutron damage. The objective of this work was to determine if a commercial optically stimulated luminescence (OSL) in vivo dosimetry system could be adapted for use in fast neutron therapy. A 50.5 MeV fast neutron beam generated by a clinical neutron therapy cyclotron was used to irradiate carbon doped aluminum oxide (Al2O3:C) optically simulated luminescence dosimeters (OSLDs) in a solid water phantom under standard calibration conditions, 150 cm SAD, 1.7 cm depth, and 10.3 × 10.0 cm field size. OSLD fading and electron trap depletion studies were performed with the OSLDs irradiated with 20 and 50 cGy and monitored over a 24-h period to determine the optimal time for reading the dosimeters during calibration. Four OSLDs per group were calibrated over a clinical dose range of 0-150 cGy. OSLD measurement uncertainties were lowered to within ±2%-3% of the expected dose by minimizing the effect of transient fading that occurs with neutron irradiation and maintaining individual calibration factors for each dosimeter. Dose dependent luminescence fading extended beyond the manufacturer's recommended 10 min period for irradiation with photon or electron beams. To minimize OSL variances caused by inconsistent fading among dosimeters, the observed optimal time for reading the OSLDs postirradiation was between 30 and 90 min. No field size, wedge factor, or gantry angle dependencies were observed in the OSLDs irradiated by the studied fast neutron beam. Measurements demonstrated that uncertainties less than ±3% were attainable in OSLDs irradiated with fast neutrons under clinical conditions. Accuracy and precision comparable to clinical OSL measurements observed with photons can be achieved by maintaining individual OSLD calibration factors and minimizing transient fading effects.

  14. Commissioning optically stimulated luminescence in vivo dosimeters for fast neutron therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, Lori A., E-mail: layoung@uw.edu; Sandison, George; Yang, Fei

    Purpose: Clinical in vivo dosimeters intended for use with photon and electron therapies have not been utilized for fast neutron therapy because they are highly susceptible to neutron damage. The objective of this work was to determine if a commercial optically stimulated luminescence (OSL) in vivo dosimetry system could be adapted for use in fast neutron therapy. Methods: A 50.5 MeV fast neutron beam generated by a clinical neutron therapy cyclotron was used to irradiate carbon doped aluminum oxide (Al{sub 2}O{sub 3}:C) optically simulated luminescence dosimeters (OSLDs) in a solid water phantom under standard calibration conditions, 150 cm SAD, 1.7more » cm depth, and 10.3 × 10.0 cm field size. OSLD fading and electron trap depletion studies were performed with the OSLDs irradiated with 20 and 50 cGy and monitored over a 24-h period to determine the optimal time for reading the dosimeters during calibration. Four OSLDs per group were calibrated over a clinical dose range of 0–150 cGy. Results: OSLD measurement uncertainties were lowered to within ±2%–3% of the expected dose by minimizing the effect of transient fading that occurs with neutron irradiation and maintaining individual calibration factors for each dosimeter. Dose dependent luminescence fading extended beyond the manufacturer’s recommended 10 min period for irradiation with photon or electron beams. To minimize OSL variances caused by inconsistent fading among dosimeters, the observed optimal time for reading the OSLDs postirradiation was between 30 and 90 min. No field size, wedge factor, or gantry angle dependencies were observed in the OSLDs irradiated by the studied fast neutron beam. Conclusions: Measurements demonstrated that uncertainties less than ±3% were attainable in OSLDs irradiated with fast neutrons under clinical conditions. Accuracy and precision comparable to clinical OSL measurements observed with photons can be achieved by maintaining individual OSLD calibration factors and minimizing transient fading effects.« less

  15. Thermally assisted OSL application for equivalent dose estimation; comparison of multiple equivalent dose values as well as saturation levels determined by luminescence and ESR techniques for a sedimentary sample collected from a fault gouge

    NASA Astrophysics Data System (ADS)

    Şahiner, Eren; Meriç, Niyazi; Polymeris, George S.

    2017-02-01

    Equivalent dose estimation (De) constitutes the most important part of either trap-charge dating techniques or dosimetry applications. In the present work, multiple, independent equivalent dose estimation approaches were adopted, using both luminescence and ESR techniques; two different minerals were studied, namely quartz as well as feldspathic polymineral samples. The work is divided into three independent parts, depending on the type of signal employed. Firstly, different De estimation approaches were carried out on both polymineral and contaminated quartz, using single aliquot regenerative dose protocols employing conventional OSL and IRSL signals, acquired at different temperatures. Secondly, ESR equivalent dose estimations using the additive dose procedure both at room temperature and at 90 K were discussed. Lastly, for the first time in the literature, a single aliquot regenerative protocol employing a thermally assisted OSL signal originating from Very Deep Traps was applied for natural minerals. Rejection criteria such as recycling and recovery ratios are also presented. The SAR protocol, whenever applied, provided with compatible De estimations with great accuracy, independent on either the type of mineral or the stimulation temperature. Low temperature ESR signals resulting from Al and Ti centers indicate very large De values due to bleaching in-ability, associated with large uncertainty values. Additionally, dose saturation of different approaches was investigated. For the signal arising from Very Deep Traps in quartz saturation is extended almost by one order of magnitude. It is interesting that most of De values yielded using different luminescence signals agree with each other and ESR Ge center has very large D0 values. The results presented above highly support the argument that the stability and the initial ESR signal of the Ge center is highly sample-dependent, without any instability problems for the cases of quartz resulting from fault gouge.

  16. OSL Dating and GPR Mapping of Palaeotsunami Inundation: A 4000-Year History of Indian Ocean Tsunamis as recorded in Sri Lanka

    NASA Astrophysics Data System (ADS)

    Premasiri, Ranjith; Styles, Peter; Shrira, Victor; Cassidy, Nigel; Schwenninger, Jean-Luc

    2015-12-01

    To evaluate and mitigate tsunami hazard, as long as possible records of inundations and dates of past events are needed. Coastal sediments deposited by tsunamis (tsunamites) can potentially provide this information. However, of the three key elements needed for reconstruction of palaeotsunamis (identification of sediments, dating and finding the inundation distance) the latter remains the most difficult. The existing methods for estimating the extent of a palaeotsunami inundation rely on extensive excavation, which is not always possible. Here, by analysing tsunamites from Sri Lanka identified using sedimentological and paleontological characteristics, we show that their internal dielectric properties differ significantly from surrounding sediments. The significant difference in the value of dielectric constant of the otherwise almost indistinguishable sediments is due to higher water content of tsunamites. The contrasts were found to be sharp and not to erode over thousands of years; they cause sizeable electromagnetic wave reflections from tsunamite sediments, which permit the use of ground-penetrating radar (GPR) to trace their extent and morphology. In this study of the 2004 Boxing Day Indian Ocean tsunami, we use GPR in two locations in Sri Lanka to trace four identified major palaeotsunami deposits for at least 400 m inland (investigation inland was constrained by inaccessible security zones). The subsurface extent of tsunamites (not available without extensive excavation) provides a good proxy for inundation. The deposits were dated using the established method of optically stimulated luminescence (OSL). This dating, partly corroborated by available historical records and independent studies, contributes to the global picture of tsunami hazard in the Indian Ocean. The proposed method of combined GPR/OSL-based reconstruction of palaeotsunami deposits enables estimates of inundation, recurrence and, therefore, tsunami hazard for any sandy coast with identifiable tsunamite deposits. The method could be also used for anchoring and synchronizing chronologies of ancient civilisations adjacent to the ocean shores.

  17. Failures in Hybrid Microcircuits During Environmental Testing. History Cases

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander

    2008-01-01

    This purpose of this viewgraph presentation is to discuss failures in hermetic hybrids observed at the GSFC PA Lab during environmental stress testing. The cases discussed are: Case I. Substrate metallization failures during Thermal cycling (TC). Case II. Flex lid-induced failure. Case Ill. Hermeticity failures during TC. Case IV. Die metallization cracking during TC. and how many test cycles and parts is necessary? Case V. Wire Bond failures after life test. Case VI. Failures caused by Au/In IMC growth.

  18. Multiphase materials with lignin. IV. Blends of hydroxypropyl cellulose with lignin

    Treesearch

    Timothy G. Rials; Wolfgang G. Glasser

    1989-01-01

    Polymer blends of hydroxypropyl cellulose (HPC) and organosolv lignin (OSL) were prepared by mixing in solutions of both pyridine and dioxane, and casting as films, and by mixing in the melt followed by extrusion. All preparations exhibited partial miscibility as evidenced by a single Tg up to a composition of 40 wt % lignin above which phase...

  19. Development of a First Sergeant Guidebook

    DTIC Science & Technology

    1984-02-01

    ANtSCLE IS 0IO. 0.)O~Iu CjCOURt-PItOAL ACTIOft *EVESR00S(@6 IS VNICE OSL Cmom T20vs %I T’a.s F& mc’ JISECTION It OIMPN REPORT FILL INinvestigation...use of radiation dosimeters and the~ principles ofrdainexposure cnrl 9. Recognize the existence of a chemical hazard and indications of a biological

  20. Operation JANGLE. Airborne Particle Studies. Project 2.5a-1

    DTIC Science & Technology

    1979-10-01

    dosimeter film, type 552. After an exposure of approxi- mately one month, the cones were removed and the film processed. This radioautograph (Fig...giving -•..eght to the idea that the base surge was Co,• osled of small particlej. 5.3 RADIOACTIVITY AS A FINCTION OF PARTICLE SIZE It was hoped that the

  1. A Representative Survey of U.S. Space Systems and Methods for Estimating Their Costs

    DTIC Science & Technology

    1992-11-01

    68 TETR.I Radose: U.S. Air Force satellites carrying radiation dosimeters Radose 06/15/63 07/30/63 Radose-5E1 09/28/63 SN39 Radose-5EIA 12105/63... OSL Orbiting Solar Laboratory OSO Orbiting Solar Observatory OSSA Office of Space Science and Applications OSSE Oriented Scintillation Spectrometer

  2. Orthogonal series generalized likelihood ratio test for failure detection and isolation. [for aircraft control

    NASA Technical Reports Server (NTRS)

    Hall, Steven R.; Walker, Bruce K.

    1990-01-01

    A new failure detection and isolation algorithm for linear dynamic systems is presented. This algorithm, the Orthogonal Series Generalized Likelihood Ratio (OSGLR) test, is based on the assumption that the failure modes of interest can be represented by truncated series expansions. This assumption leads to a failure detection algorithm with several desirable properties. Computer simulation results are presented for the detection of the failures of actuators and sensors of a C-130 aircraft. The results show that the OSGLR test generally performs as well as the GLR test in terms of time to detect a failure and is more robust to failure mode uncertainty. However, the OSGLR test is also somewhat more sensitive to modeling errors than the GLR test.

  3. Space Shuttle Solid Rocket Booster Decelerator Subsystem Drop Test 3 - Anatomy of a failure

    NASA Technical Reports Server (NTRS)

    Runkle, R. E.; Woodis, W. R.

    1979-01-01

    A test failure dramatically points out a design weakness or the limits of the material in the test article. In a low budget test program, with a very limited number of tests, a test failure sparks supreme efforts to investigate, analyze, and/or explain the anomaly and to improve the design such that the failure will not recur. The third air drop of the Space Shuttle Solid Rocket Booster Recovery System experienced such a dramatic failure. On air drop 3, the 54-ft drogue parachute was totally destroyed 0.7 sec after deployment. The parachute failure investigation, based on analysis of drop test data and supporting ground element test results is presented. Drogue design modifications are also discussed.

  4. Role of failure-mechanism identification in accelerated testing

    NASA Technical Reports Server (NTRS)

    Hu, J. M.; Barker, D.; Dasgupta, A.; Arora, A.

    1993-01-01

    Accelerated life testing techniques provide a short-cut method to investigate the reliability of electronic devices with respect to certain dominant failure mechanisms that occur under normal operating conditions. However, accelerated tests have often been conducted without knowledge of the failure mechanisms and without ensuring that the test accelerated the same mechanism as that observed under normal operating conditions. This paper summarizes common failure mechanisms in electronic devices and packages and investigates possible failure mechanism shifting during accelerated testing.

  5. Spacecraft Parachute Recovery System Testing from a Failure Rate Perspective

    NASA Technical Reports Server (NTRS)

    Stewart, Christine E.

    2013-01-01

    Spacecraft parachute recovery systems, especially those with a parachute cluster, require testing to identify and reduce failures. This is especially important when the spacecraft in question is human-rated. Due to the recent effort to make spaceflight affordable, the importance of determining a minimum requirement for testing has increased. The number of tests required to achieve a mature design, with a relatively constant failure rate, can be estimated from a review of previous complex spacecraft recovery systems. Examination of the Apollo parachute testing and the Shuttle Solid Rocket Booster recovery chute system operation will clarify at which point in those programs the system reached maturity. This examination will also clarify the risks inherent in not performing a sufficient number of tests prior to operation with humans on-board. When looking at complex parachute systems used in spaceflight landing systems, a pattern begins to emerge regarding the need for a minimum amount of testing required to wring out the failure modes and reduce the failure rate of the parachute system to an acceptable level for human spaceflight. Not only a sufficient number of system level testing, but also the ability to update the design as failure modes are found is required to drive the failure rate of the system down to an acceptable level. In addition, sufficient data and images are necessary to identify incipient failure modes or to identify failure causes when a system failure occurs. In order to demonstrate the need for sufficient system level testing prior to an acceptable failure rate, the Apollo Earth Landing System (ELS) test program and the Shuttle Solid Rocket Booster Recovery System failure history will be examined, as well as some experiences in the Orion Capsule Parachute Assembly System will be noted.

  6. A simple low-cost of liquid I-131 dispenser for routine radiopharmaceutical dispensing at nuclear medicine department, Institut Kanser Negara

    NASA Astrophysics Data System (ADS)

    Said, M. A.; Ashhar, Z. N.; Suhaimi, N. E. F.; Zainon, R.

    2016-01-01

    In routine radiopharmaceutical Iodine-131 (131I) dispensing, the amount of radiation dose received by the personnel depends on the distance between the personnel and the source, the time spent manipulating the source and the amount of shielding used to reduce the dose rate from the source. The novel iRAD-I131 dispenser using recycle 131I liquid lead pot will lead into low cost production, less maintenance and low dose received by the personnel that prepared the 131I. The new fabricated of low cost 131I dispenser was tested and the dose received by personnel were evaluated. The body of lead material is made from 2.5 cm lead shielded coated with epoxy paint to absorb the radiation dose up to 7.4 GBq of 131 I. The lead pot was supported with two stainless steel rod. The Optically Stimulated Luminescence (OSL) nanodot was used in this study to measure the dose rate at both extremities for every personnel who prepared the 131I. Each OSL nanodot was attached at the fingertip. Three different personnel (experienced between one to ten years above in preparing the radiopharmaceuticals) were participated in this study. The average equivalent dose at right and left hand were 122.694 ± 121.637 µSv/GBq and 77.281 ± 62.146 µSv/GBq respectively. This study found that the dose exposure received using iRAD-I131 was less up to seven times compared to the conventional method. The comparison of experimental data using iRAD-I131 and established radiopharmaceutical dispenser was also discussed. The innovation of 131I dispenser is highly recommended in a small radiopharmaceutical facility with limited budget. The novel iRAD-I131 enables implementation of higher output liquid dispensing with low radiation dose to the personnel.

  7. Sedimentary development and correlation of Late Quaternary terraces in the Kyrenia Range, northern Cyprus, using a combination of sedimentology and optical luminescence data

    NASA Astrophysics Data System (ADS)

    Palamakumbura, Romesh N.; Robertson, Alastair H. F.; Kinnaird, Tim C.; Sanderson, David C. W.

    2016-01-01

    This study focuses on the younger of a series of Quaternary terraces along the flanks of the Kyrenia Range in northern Cyprus, specifically the Kyrenia (Girne) and the Koupia terraces. The Kyrenia (Girne) terrace is tentatively correlated with oxygen isotope stage 5 (125 Ka), and the Koupia terrace with oxygen isotope stage 3 (<50 Ka). Along the northern flank of the range, the Kyrenia (Girne) terrace deposits (5-20 m above modern sea level) typically begin with a basal lag conglomerate and then pass upwards into shallow-marine calcarenites and then into variable aeolianites, paleosols and fluvial deposits (up to 20 m thick). In contrast, the Koupia terrace (<2 m above modern sea level) consists of aeolianites and shallow-marine calcarenites (up to 8 m thick). The equivalent deposits along the southern flank of the range are entirely non-marine fluvial mud, sands and conglomerates. The marine to continental terrace systems can be tentatively correlated based on mapping, height above modern sea level and sedimentary facies. However, variable preservation and patchy exposure require such correlations to be independently tested. To achieve this, a portable optically stimulated luminescence (OSL) reader was used to determine the luminescence characteristics of the two terrace systems. Luminescence profiles show major differences in luminescence characteristics between the two terrace depositional systems, which can be related to sedimentary processes, provenance and age. These features allow sections in different areas to be effectively correlated. Individual sections show luminescence properties that are generally consistent with an expected up-sequence decrease in age. However, the younger Koupia terrace deposits show higher luminescence intensities compared with the older Kyrenia (Girne) terrace deposits. This can be explained by multiple phases of reworking of the Kyrenia (Girne) terrace deposits, which changed the luminescence characteristics of the sediment. The use of the portable OSL reader is therefore an effective means of correlating Late Quaternary terrace deposits in northern Cyprus and probably also elsewhere.

  8. Wringing the last drop of optically stimulated luminescence response for accurate dating of glacial sediments

    NASA Astrophysics Data System (ADS)

    Medialdea, Alicia; Bateman, Mark D.; Evans, David J.; Roberts, David H.; Chiverrell, Richard C.; Clark, Chris D.

    2017-04-01

    BRITICE-CHRONO is a NERC-funded consortium project of more than 40 researchers aiming to establish the retreat patterns of the last British and Irish Ice Sheet. For this purpose, optically stimulated luminescence (OSL) dating, among other dating techniques, has been used in order to establish accurate chronology. More than 150 samples from glacial environments have been dated and provide key information for modelling of the ice retreat. Nevertheless, luminescence dating of glacial sediments has proven to be challenging: first, glacial sediments were often affected by incomplete bleaching and secondly, quartz grains within the sediments sampled were often characterized by complex luminescence behaviour; characterized by dim signal and low reproducibility. Specific statistical approaches have been used to over come the former to enable the estimated ages to be based on grain populations most likely to have been well bleached. This latest work presents how issues surrounding complex luminescence behaviour were over-come in order to obtain accurate OSL ages. This study has been performed on two samples of bedded sand originated on an ice walled lake plain, in Lincolnshire, UK. Quartz extracts from each sample were artificially bleached and irradiated to known doses. Dose recovery tests have been carried out under different conditions to study the effect of: preheat temperature, thermal quenching, contribution of slow components, hot bleach after a measuring cycles and IR stimulation. Measurements have been performed on different luminescence readers to study the possible contribution of instrument reproducibility. These have shown that a great variability can be observed not only among the studied samples but also within a specific site and even a specific sample. In order to determine an accurate chronology and realistic uncertainties to the estimated ages, this variability must be taken into account. Tight acceptance criteria to measured doses from natural, not exposed, aliquots have been applied. These derived on reproducible dose distributions from which accurate ages could be estimated.

  9. Luminescence dating and palaeomagnetic age constraint on hominins from Sima de los Huesos, Atapuerca, Spain.

    PubMed

    Arnold, Lee J; Demuro, Martina; Parés, Josep M; Arsuaga, Juan Luis; Aranburu, Arantza; Bermúdez de Castro, José María; Carbonell, Eudald

    2014-02-01

    Establishing a reliable chronology on the extensive hominin remains at Sima de los Huesos is critical for an improved understanding of the complex evolutionary histories and phylogenetic relationships of the European Middle Pleistocene hominin record. In this study, we use a combination of 'extended-range' luminescence dating techniques and palaeomagnetism to provide new age constraint on sedimentary infills that are unambiguously associated with the Sima fossil assemblage. Post-infrared-infrared stimulated luminescence (pIR-IR) dating of K-feldspars and thermally transferred optically stimulated luminescence (TT-OSL) dating of individual quartz grains provide weighted mean ages of 433 ± 15 ka (thousands of years) and 416 ± 19 ka, respectively, for allochthonous sedimentary horizons overlying the hominin-bearing clay breccia. The six replicate luminescence ages obtained for this deposit are reproducible and provide a combined minimum age estimate of 427 ± 12 ka for the underlying hominin fossils. Palaeomagnetic directions for the luminescence dated sediment horizon and underlying fossiliferous clays display exclusively normal polarities. These findings are consistent with the luminescence dating results and confirm that the hominin fossil horizon accumulated during the Brunhes Chron, i.e., within the last 780 ka. The new bracketing age constraint for the Sima hominins is in broad agreement with radiometrically dated Homo heidelbergensis fossil sites, such as Mauer and Arago, and suggests that the split of the H. neanderthalensis and H. sapiens lineages took place during the early Middle Pleistocene. More widespread numerical dating of key Early and Middle Pleistocene fossil sites across Europe is needed to test and refine competing models of hominin evolution. The new luminescence chronologies presented in this study demonstrate the versatility of TT-OSL and pIR-IR techniques and the potential role they could play in helping to refine evolutionary histories over Middle Pleistocene timescales. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. A simple low-cost of liquid I-131 dispenser for routine radiopharmaceutical dispensing at nuclear medicine department, Institut Kanser Negara

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Said, M. A.; Suhaimi, N. E. F.; Ashhar, Z. N., E-mail: aminhpj@gmail.com

    In routine radiopharmaceutical Iodine-131 ({sup 131}I) dispensing, the amount of radiation dose received by the personnel depends on the distance between the personnel and the source, the time spent manipulating the source and the amount of shielding used to reduce the dose rate from the source. The novel iRAD-I131 dispenser using recycle {sup 131}I liquid lead pot will lead into low cost production, less maintenance and low dose received by the personnel that prepared the {sup 131}I. The new fabricated of low cost {sup 131}I dispenser was tested and the dose received by personnel were evaluated. The body of leadmore » material is made from 2.5 cm lead shielded coated with epoxy paint to absorb the radiation dose up to 7.4 GBq of {sup 131} I. The lead pot was supported with two stainless steel rod. The Optically Stimulated Luminescence (OSL) nanodot was used in this study to measure the dose rate at both extremities for every personnel who prepared the {sup 131}I. Each OSL nanodot was attached at the fingertip. Three different personnel (experienced between one to ten years above in preparing the radiopharmaceuticals) were participated in this study. The average equivalent dose at right and left hand were 122.694 ± 121.637 µSv/GBq and 77.281 ± 62.146 µSv/GBq respectively. This study found that the dose exposure received using iRAD-I131 was less up to seven times compared to the conventional method. The comparison of experimental data using iRAD-I131 and established radiopharmaceutical dispenser was also discussed. The innovation of {sup 131}I dispenser is highly recommended in a small radiopharmaceutical facility with limited budget. The novel iRAD-I131 enables implementation of higher output liquid dispensing with low radiation dose to the personnel.« less

  11. Combating WMD Journal. Issue 2

    DTIC Science & Technology

    2008-03-01

    can be conducted utilizing passive detectors such as thermoluminescent dosime- ters (TLDs) or optically stimulated luminescent ( OSL ) dosimeters ...reasonable estimate of the dose. The challenge in high-energy bremsstrahlung fields is that current (standard) dosimeters do not provide for CPE...above a few MeV. CPE can be obtained by placing tissue- equivalent material (such as a build- up cap) around the dosimeter . This Dosimetry Needs

  12. Fluvial terraces of the Little River Valley, Atlantic Coastal Plain, North Carolina

    Treesearch

    Bradley Suther; David Leigh; George Brook

    2011-01-01

    An optically-stimulated luminescence (OSL) and radiocarbon chronology is presented for fluvial terraces of the Little River, a tributary to the Cape Fear River that drains 880 km2 of the Sandhills Province of the upper Coastal Plain of North Carolina. This study differs from previous work in the southeastern Atlantic Coastal Plain in that numerical age estimates are...

  13. Constraints on the age of the Great Sand Dunes, Colorado, from subsurface stratigraphy and OSL dates

    USGS Publications Warehouse

    Madole, Richard F.; Mahan, Shannon; Romig, Joseph H.; Havens, Jeremy C.

    2013-01-01

    The age of the Great Sand Dunes has been debated for nearly 150 yr. Seven ages ranging from Miocene to late Holocene have been proposed for them. This paper presents new information—chiefly subsurface stratigraphic data, OSL dates, and geomorphic evidence—that indicates that the Great Sand Dunes began to form in the latter part of the middle Pleistocene. The dunes overlie a thick wedge of piedmont-slope deposits, which in turn overlies sediment of Lake Alamosa, a paleolake that began to drain about 440 ka. The wedge of piedmont-slope deposits extends westward for at least 23 km and is as much as 60 m thick at a distance of 10 km from the Sangre de Cristo Range. Ostracodes from one well indicate that the eastern shoreline of Lake Alamosa extended to within 4.3 km of where the Great Sand Dunes eventually formed. The time represented by the wedge of piedmont-slope deposits is not known exactly, but the wedge post-dates 440 ka and was in place prior to 130 ka because by then the dunes overlying it were sufficiently close and tall enough to obstruct streams draining from the Sangre de Cristo Range.

  14. A non-destructive method for dating human remains

    USGS Publications Warehouse

    Lail, Warren K.; Sammeth, David; Mahan, Shannon; Nevins, Jason

    2013-01-01

    The skeletal remains of several Native Americans were recovered in an eroded state from a creek bank in northeastern New Mexico. Subsequently stored in a nearby museum, the remains became lost for almost 36 years. In a recent effort to repatriate the remains, it was necessary to fit them into a cultural chronology in order to determine the appropriate tribe(s) for consultation pursuant to the Native American Grave Protection and Repatriation Act (NAGPRA). Because the remains were found in an eroded context with no artifacts or funerary objects, their age was unknown. Having been asked to avoid destructive dating methods such as radiocarbon dating, the authors used Optically Stimulated Luminescence (OSL) to date the sediments embedded in the cranium. The OSL analyses yielded reliable dates between A.D. 1415 and A.D. 1495. Accordingly, we conclude that the remains were interred somewhat earlier than A.D. 1415, but no later than A.D. 1495. We believe the remains are from individuals ancestral to the Ute Mouache Band, which is now being contacted for repatriation efforts. Not only do our methods contribute to the immediate repatriation efforts, they provide archaeologists with a versatile, non-destructive, numerical dating method that can be used in many burial contexts.

  15. Barrier island response to late Holocene climate events, North Carolina, USA

    USGS Publications Warehouse

    Mallinson, D.J.; Smith, C.W.; Mahan, S.; Culver, S.J.; McDowell, K.

    2011-01-01

    The Outer Banks barrier islands of North Carolina, USA, contain a geologic record of inlet activity that extends from ca. 2200. cal. yr BP to the present, and can be used as a proxy for storm activity. Optically stimulated luminescence (OSL) dating (26 samples) of inlet-fill and flood tide delta deposits, recognized in cores and geophysical data, provides the basis for understanding the chronology of storm impacts and comparison to other paleoclimate proxy data. OSL ages of historical inlet fill compare favorably to historical documentation of inlet activity, providing confidence in the technique. Comparison suggests that the Medieval Warm Period (MWP) and Little Ice Age (LIA) were both characterized by elevated storm conditions as indicated by much greater inlet activity relative to today. Given present understanding of atmospheric circulation patterns and sea-surface temperatures during the MWP and LIA, we suggest that increased inlet activity during the MWP responded to intensified hurricane impacts, while elevated inlet activity during the LIA was in response to increased nor'easter activity. A general decrease in storminess at mid-latitudes in the North Atlantic over the last 300. yr has allowed the system to evolve into a more continuous barrier with few inlets. ?? 2011 University of Washington.

  16. Quaternary geologic map of the north-central part of the Salinas River Valley and Arroyo Seco, Monterey County, California

    USGS Publications Warehouse

    Taylor, Emily M.; Sweetkind, Donald S.

    2014-01-01

    Arroyo Seco, a perennial drainage in the central Coast Range of California, records a sequence of strath terraces. These terraces preserve an erosional and depositional history, controlled by both climate change and regional tectonics. These deposits have been mapped and correlated on the basis of field investigations, digital terrain analysis, stream gradient profiles, evaluation of published regional soil maps, and satellite imagery. Seven of the strath terraces and associated alluvial fans have been dated by optically stimulated luminescence (OSL) or infrared stimulated luminescence (IRSL). The OSL and IRSL dates on seven of the strath terraces and associated alluvial fans in Arroyo Seco are approximately >120 ka, >65 ka, 51–46 ka, 36–35 ka, 9 ka, and 2–1 ka. These dates generally fall within the range of ages reported from many well-dated marine terraces on the California coast that are formed during sea-level high stands. Tectonic movements, consistently upward, result in a constantly and slowly emerging coastline, however, the regional effects of climate change and resulting eustatic sea-level rises are interpreted as the driving mechanism for erosion and aggradation in Arroyo Seco.

  17. Survey of patient dosimetry for head and neck cancer patients undergoing external radiotherapy treatment: a study from northeastern hospitals of India.

    PubMed

    Sharma, Arunkumar B; Singh, Tomcha Th; Singh, Khelendra N; Gartia, R K

    2009-01-01

    To study dosimetry of patients during the external radiotherapy of head and neck cancers from different hospitals of the northeastern region (NER) of India. 35 confirmed cases of head and neck cancers reporting to three different hospitals in the NER of India who underwent radiation treatment were the materials for the study. Dosimetry was carried out at 8(eight) anatomical points to these patients, namely, target (entrance and exit points), forehead, chest, abdomen, gonad, arm, and leg respectively by thermoluminescence (TL) as well as optically stimulated luminescence (OSL) dosimeters. Unlike conventional appliances, we used common iodized salt as TL/OSL phosphor. Patient dosimetry was found to vary with an average of 1.17 +/- 0.39 Sv at forehead, 1.24 +/- 0.39 Sv at chest, 0.52 +/- 0.13 Sv at gonad to a minimum of 0.26 +/- 0.07 Sv at leg areas when exposed to a cumulative dose of 65 Sv at the target. Maximum dose received from a stray radiation is about 1.5 Sv at forehead/chest and dosimetry of patient among the three centers is not significantly different at the 5% level of probability.

  18. Optical, scintillation and dosimeter properties of MgO:Tb translucent ceramics synthesized by the SPS method

    NASA Astrophysics Data System (ADS)

    Kawano, Naoki; Kato, Takumi; Okada, Go; Kawaguchi, Noriaki; Yanagida, Takayuki

    2017-11-01

    MgO translucent ceramics doped with different concentrations of Tb (0.01, 0.05, 0.1, 0.5%) were prepared by the Spark Plasma Sintering (SPS) method. Further, the optical, scintillation, dosimeter properties of were evaluated systematically. In the photoluminescence (PL) and scintillation spectra, sharp emission peaks due to the 4f-4f transitions of Tb3+ were observed. In the PL and scintillation decay curves, the decay time constants were a few ms which were on a typical order of the 4f-4f transitions of Tb3+. The thermally-stimulated luminescence (TSL) glow curves exhibited glow peaks around 80, 160 °C after X ray irradiation of 10 mGy. The intensity of TSL peak at 160 °C exhibited a linear response against X-ray dose over a dose range of 0.1-10 mGy. The optically-stimulated luminescence (OSL) under 590 nm stimulation exhibited strong emissions due to Tb3+ around 385-550 nm after X-ray irradiation. As in TSL, the intensity of OSL peak showed a linear response to X-ray dose, and the dynamic range confirmed was 0.1-1000 mGy.

  19. Late Quaternary environments of the Waco Mammoth site, Texas USA

    NASA Astrophysics Data System (ADS)

    Nordt, Lee; Bongino, John; Forman, Steven; Esker, Don; Benedict, Anita

    2015-11-01

    The Waco Mammoth Site (WMS) in central Texas contains the remains of the largest mammoth herd (Mammuthus columbi) in North America that died in a single catastrophic event. Most mammoths at the site died on a gravel bar of the ancient Bosque River adjacent to a collapsing tributary wall. However, the timing and cause of death of the 26 mammoths documented to date are controversial. The objectives of this research are to: describe and interpret the alluvial stratigraphy and infer the cause of death, employ optically stimulated luminescence (OSL) dating to determine the timing of death, and analyze stable C isotopes of pedogenic carbonate to infer local plant communities, dietary habits, and summer temperatures. Dating of quartz from seven sediment samples by OSL places the death event to a weighted mean of 66.8 ± 5.0 ka. The site is coeval with Marine Oxygen Isotope Stage 4, consistent with our reconstructed mean July temperatures 4°C cooler than today based on a buried soil isotopic transfer function. Our buried soil isotopic interpretation of a dominance of C3 plants is contrary to previous studies of mammoth tooth enamel at the site suggesting a dietary preference for warm season grasses (C4).

  20. Taming Test Anxiety: The Activation of Failure-Related Concepts Enhances Cognitive Test Performance of Test-Anxious Students

    ERIC Educational Resources Information Center

    Tempel, Tobias; Neumann, Roland

    2016-01-01

    We investigated processes underlying performance decrements of highly test-anxious persons. Three experiments contrasted conditions that differed in the degree of activation of concepts related to failure. Participants memorized a list of words either containing words related to failure or containing no words related to failure in Experiment 1. In…

  1. 49 CFR Appendix D to Part 230 - Civil Penalty Schedule

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the boiler 1,000 2,000 230.36Hydrostatic testing of boilers: (a) Failure to perform hydrostatic test of boiler as required 1,500 3,000 (b) Failure to properly perform hydrostatic test 1,500 3,000 (c) Failure to properly inspect boiler after conducting hydrostatic test above MAWP 1,500 3,000 230.37 Failure...

  2. Reliability Programs for Nonelectronic Designs. Volume 2

    DTIC Science & Technology

    1983-04-01

    afforded. Differ- ences between critical and minor failures must be defined in the RFP so that the test need not be stopped for minor failures. However...not be afforded. Specialized test plans must be developed for nonelectronic equipment. First, differences between critical and minor failures must be...determined prior to initiating the test program so that the test need not be stopped for minor failures. Second, although the test must be interrupted

  3. Timing and origin for sand dunes in the Green River Lowland of Illinois, upper Mississippi River Valley, USA

    USGS Publications Warehouse

    Miao, X.; Hanson, P.R.; Wang, Hongfang; Young, A.R.

    2010-01-01

    The recent increase in dune studies in North America has been heavily focused in the Great Plains, while less attention has historically been given to the dune fields east of the Mississippi River. Here we report ages and suggest a potential sediment source for sand dunes in the Green River Lowland, Illinois, which may provide a better understanding of the dynamic interactions between eolian, glacial, lacustrine and fluvial processes that shaped the landscapes of the upper Midwest. Seven coherent optically stimulated luminescence ages (OSL, or optical ages) obtained from four sites suggest that major dune construction in the Green River Lowland occurred within a narrow time window around 17,500 ago. This implies either an enhanced aridity or an episodic increase of sediment supply at 17,500 years ago, or combination of the both. Contrary to previous assertions that dune sand was sourced from the deflation of the underlying outwash sand deposited when the Lake Michigan Lobe retreated from the area, we propose that Green River Lowland dunes sand originated from the Green Bay Lobe through the Rock River. Specifically, sediment supply increased in the Rock River valley during drainage of Glacial Lake Scuppernong, which formed between ???18,000 and 17,000 years ago, when the Green Bay Lobe retreated from its terminal moraine. The lake drained catastrophically through the Rock River valley, providing glacial sediment and water to erode the preexisting sandy sediments. Throughout the remainder of the late Pleistocene, the Laurentide Ice Sheet drained into larger more northerly glacial lakes that in turn drained through other river valleys. Therefore, the dunes in the Green River Lowland formed only during the catastrophic drainage of Glacial Lake Scuppernong, but were stabilized through the remainder of the Pleistocene. This scenario explains the abrupt dune construction around 17,500 years ago, and explains the lack of later dune activity up to the Pleistocene-Holocene transition. OSL and radiocarbon ages also indicate that dunes were reactivated during the early, middle and late Holocene. Some eolian activation occurred within well-defined dry intervals in the upper Midwest, suggesting that increased aridity may have been the primary driver in mobilizing sand. However, many ages do not correspond to drier periods. In contrast to the relative coherency of the Pleistocene OSL ages from multiple study sites, the Holocene OSL ages do not overlap from one site to another, suggesting that increased aridity alone cannot explain the multiple phases of dune reactivation in the Holocene. Therefore, we conclude that the combined effect of localized disturbances and greater aridity acted in concert to increase eolian sand activity in the Holocene. The multiple periods of eolian activity during the Holocene suggest a high potential for future sand activation in the region, and these results are informative for environmental prediction and potential future mitigation.

  4. Chronology of Terra Firme formation in western Amazonia and implications for the diversification of Amazonian biota

    NASA Astrophysics Data System (ADS)

    Pupim, Fabiano do N.; Sawakushi, André O.; Hartmann, Gelvam A.; Savian, Jairo F.; Kern, Andrea K.; Mineli, Thays D.; Cruz, Francisco W.; Almeida, Renato P.; Grohmann, Carlos H.; Ribas, Camila C.; d'Horta, Fernando M.; Bertassoli, Dailson J.; Marconato, André; Nogueira, Luciana; Lohmann, Lúcia G.

    2017-04-01

    The shift from a large wetland dominated by avulsive channels and flooded forests to the incised transcontinental Amazon River valley (Várzea) bounded by non-flooded forests (Terra Firme) is suggested as one of the main drivers of diversification of the mega diverse Amazonian Biota. Nonetheless, there is no consensus about the timing of this landscape shift, with the current literature suggesting a period that ranges from the Miocene (11 Ma) and the Late Pleistocene (100 ka). This uncertainty may be due to a lack of absolute ages for the sediments forming Terra Firme forest substrates in western Amazonian lowlands. In Brazil, the Içá Formation represents the uppermost fluvial deposits of Terra Firme forests substrates in western Amazonia. Therefore, a reliable chronology for the last depositional stage of the Içá Formation is key for an improved understanding of the formation of the current Terra Firme-Várzea system. Four sediment profiles were sampled along the margins of the Solimões and Içá rivers for Optically Stimulated Luminescence (OSL) dating, geomagnetic excursions, and palynological analysis. OSL dating was performed in twelve samples using a Single Aliquot Regeneration (SAR) protocol in quartz sand grains. The equivalent doses ranged from 47 to 130 Gy (Central Age Model) and the dose rate values ranged from 0.4 to 2.0 Gy/ka. The resulting sediment burial ages range from 48 to 112 ka. Paleomagnetic data were obtained from samples collected at same profiles sampled for OSL dating and results suggest the presence of Post-Blake geomagnetic excursion ( 100 ka). The age of 100 ka for Post-Blake excursion are adopted for the Geomagnetic Instability Time Scale. Pollen assemblage data show a similarity to a more modern flora and the presence of Alnus clearly points towards Pleistocene deposition as it is unknown before in South America. The combined OSL, paleomagnetism and pollen data is a robust geochronological dataset that indicates Late Pleistocene ages for the last stage of built up of the Terra Firme in a broad region of the western Brazilian Amazonian lowlands. Therefore, the present-day unconformity between Terra Firme and Várzea deposits were formed by fluvial incision during the late Pleistocene and Holocene, which seems to be related with precipitation changes in the South American monsoon system. Our geochronological dataset point to important landscape changes during the late Pleistocene, with expansion of non-flooded Terra Firme and retraction of Várzea floodplain forests. This transition probably had important implications for the development of modern phylogeographical and biogeographical patterns in western Amazonia during the Quaternary. Future efforts will focus on dating drill-core sediment records using cosmogenic nuclides to extend the age range. Financial support: FAPESP 2009/53988-8, 2012/50260-6, 2014/23334-4, 2014/09800-2, 2016/09293-9; 2016/02656-9; CNPq 3009223/2014-8, 307647/2015-3; NSF DEB 1241066 and NASA.

  5. Characterization and implementation of OSL dosimeters for use in evaluating the efficacy of organ-based tube current modulation for CT scans of the face and orbits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marsh, R. M.; Silosky, M., E-mail: michael.silosky@ucdenver.edu

    Purpose: The purpose of this work was to characterize commercially available optically stimulated luminescent (OSL) dosimeters for general clinical applications and apply the results to the development of a method to evaluate the efficacy of a vendor-specific organ-based tube current modulation application for both phantom and clinical computed tomography (CT) scans of the face and orbits. Methods: This study consisted of three components: (1) thorough characterization of the dosimeters for CT scans in phantom, including evaluations of depletion, fading, angular dependence, and conversion from counts to absorbed dose; (2) evaluation of the efficacy of using plastic glasses to position themore » dosimeters over the eyes in both phantom and clinical studies; and (3) preliminary dosimetry measurements made using organ-based tube current modulation in computed tomography dose index (CTDI) and anthropomorphic phantom studies. Results: (1) Depletion effects were found to have a linear relationship with the output of the OSL dosimeters (R{sup 2} = 0.96). Fading was found to affect dosimeter readings during the first two hours following exposure but had no effect during the remaining 60-h period observed. No significant angular dependence was observed for the exposure conditions used in this study (with p-values ranging from 0.9 to 0.26 for all t-tests). Dosimeter counts varied linearly with absorbed dose when measured in the center and 12 o’clock positions of the CTDI phantoms. These linear models of counts versus absorbed dose had overlapping 95% confidence intervals for the intercepts but not for the slopes. (2) When dosimeters were positioned using safety glasses, there was no adverse effect on image quality, and there was no statistically significant difference between this placement and placement of the dosimeters directly on the eyes of the phantom (p = 0.24). (3) When using organ-based tube current modulation, the dose to the lens of the eye was reduced between 19% and 43%, depending on the scan protocol used and the positioning of the phantom. Furthermore, the amount of dose reduction was significantly affected by the vertical position of the phantom, with the largest reduction in dose seen when the phantom was centered in the gantry. Conclusions: (1) An appropriate correction factor, specific to CT scanning, was developed to account for depletion and fading characteristics of the dosimeters. Additionally, an equation to convert dosimeter counts to absorbed dose was established. (2) The use of plastic safety glasses was validated as an appropriate positioning device when measuring dose to the lens of the eye. (3) The use of organ-based tube current modulation can reduce dose to the lens of the eye during CT scanning. The amount of dose reduction, however, is largely influenced by the positioning of the anatomy in the gantry.« less

  6. Characterization and implementation of OSL dosimeters for use in evaluating the efficacy of organ-based tube current modulation for CT scans of the face and orbits.

    PubMed

    Marsh, R M; Silosky, M

    2015-04-01

    The purpose of this work was to characterize commercially available optically stimulated luminescent (OSL) dosimeters for general clinical applications and apply the results to the development of a method to evaluate the efficacy of a vendor-specific organ-based tube current modulation application for both phantom and clinical computed tomography (CT) scans of the face and orbits. This study consisted of three components: (1) thorough characterization of the dosimeters for CT scans in phantom, including evaluations of depletion, fading, angular dependence, and conversion from counts to absorbed dose; (2) evaluation of the efficacy of using plastic glasses to position the dosimeters over the eyes in both phantom and clinical studies; and (3) preliminary dosimetry measurements made using organ-based tube current modulation in computed tomography dose index (CTDI) and anthropomorphic phantom studies. (1) Depletion effects were found to have a linear relationship with the output of the OSL dosimeters (R(2) = 0.96). Fading was found to affect dosimeter readings during the first two hours following exposure but had no effect during the remaining 60-h period observed. No significant angular dependence was observed for the exposure conditions used in this study (with p-values ranging from 0.9 to 0.26 for all t-tests). Dosimeter counts varied linearly with absorbed dose when measured in the center and 12 o'clock positions of the CTDI phantoms. These linear models of counts versus absorbed dose had overlapping 95% confidence intervals for the intercepts but not for the slopes. (2) When dosimeters were positioned using safety glasses, there was no adverse effect on image quality, and there was no statistically significant difference between this placement and placement of the dosimeters directly on the eyes of the phantom (p = 0.24). (3) When using organ-based tube current modulation, the dose to the lens of the eye was reduced between 19% and 43%, depending on the scan protocol used and the positioning of the phantom. Furthermore, the amount of dose reduction was significantly affected by the vertical position of the phantom, with the largest reduction in dose seen when the phantom was centered in the gantry. (1) An appropriate correction factor, specific to CT scanning, was developed to account for depletion and fading characteristics of the dosimeters. Additionally, an equation to convert dosimeter counts to absorbed dose was established. (2) The use of plastic safety glasses was validated as an appropriate positioning device when measuring dose to the lens of the eye. (3) The use of organ-based tube current modulation can reduce dose to the lens of the eye during CT scanning. The amount of dose reduction, however, is largely influenced by the positioning of the anatomy in the gantry.

  7. Development of wheelchair caster testing equipment and preliminary testing of caster models

    PubMed Central

    Mhatre, Anand; Ott, Joseph

    2017-01-01

    Background Because of the adverse environmental conditions present in less-resourced environments (LREs), the World Health Organization (WHO) has recommended that specialised wheelchair test methods may need to be developed to support product quality standards in these environments. A group of experts identified caster test methods as a high priority because of their common failure in LREs, and the insufficiency of existing test methods described in the International Organization for Standardization (ISO) Wheelchair Testing Standards (ISO 7176). Objectives To develop and demonstrate the feasibility of a caster system test method. Method Background literature and expert opinions were collected to identify existing caster test methods, caster failures common in LREs and environmental conditions present in LREs. Several conceptual designs for the caster testing method were developed, and through an iterative process using expert feedback, a final concept and a design were developed and a prototype was fabricated. Feasibility tests were conducted by testing a series of caster systems from wheelchairs used in LREs, and failure modes were recorded and compared to anecdotal reports about field failures. Results The new caster testing system was developed and it provides the flexibility to expose caster systems to typical conditions in LREs. Caster failures such as stem bolt fractures, fork fractures, bearing failures and tire cracking occurred during testing trials and are consistent with field failures. Conclusion The new caster test system has the capability to incorporate necessary test factors that degrade caster quality in LREs. Future work includes developing and validating a testing protocol that results in failure modes common during wheelchair use in LRE. PMID:29062762

  8. First overpower tests of metallic IFR [Integral Fast Reactor] fuel in TREAT [Transient Reactor Test Facility]: Data and analysis from tests M5, M6, and M7

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauer, T. H.; Robinson, W. R.; Holland, J. W.

    1989-12-01

    Results and analyses of margin to cladding failure and pre-failure axial expansion of metallic fuel are reported for TREAT in-pile transient overpower tests M5--M7. These are the first such tests on reference binary and ternary alloy fuel of the Integral Fast Reactor (IFR) concept with burnup ranging from 1 to 10 at. %. In all cases, test fuel was subjected to an exponential power rise on an 8 s period until either incipient or actual cladding failure was achieved. Objectives, designs and methods are described with emphasis on developments unique to metal fuel safety testing. The resulting database for claddingmore » failure threshold and prefailure fuel expansion is presented. The nature of the observed cladding failure and resultant fuel dispersals is described. Simple models of cladding failures and pre-failure axial expansions are described and compared with experimental results. Reported results include: temperature, flow, and pressure data from test instrumentation; fuel motion diagnostic data principally from the fast neutron hodoscope; and test remains described from both destructive and non-destructive post-test examination. 24 refs., 144 figs., 17 tabs.« less

  9. Operation CASTLE. Radiological Safety

    DTIC Science & Technology

    1981-04-01

    Electronic Section . . . .. 42 5.3 Photodosimetry and Records Section . . . . . . . 43 5.3.1 Film Packet . . . . . . . . . . 43 5.3.2 Dosimeters ...Accuracy of Du Pont Film Packet 559 as a Personnel Dosimeter . . . 61 A.2 Relative Sensitivity of Films Behind Lead Filters . 61 A.3 Variations of...project and Holmes and Narver (H&N) supervisory personnel as radiological- safety monitors. Three schools were conducted: osle at the Nevada Proving

  10. ESR and U-series analyses of faunal material from Cuddie Springs, NSW, Australia: implications for the timing of the extinction of the Australian megafauna

    NASA Astrophysics Data System (ADS)

    Grün, Rainer; Eggins, Stephen; Aubert, Maxime; Spooner, Nigel; Pike, Alistair W. G.; Müller, Wolfgang

    2010-03-01

    The timing and cause of late Pleistocene faunal extinctions in Australia are subjects of a debate that has become polarised by two vigorously defended views. One contends that the late Pleistocene extinction was a short event caused by humans colonising the Australian continent, whereas the other promotes a gradual demise of the fauna, over a period of at least 10-20 ka, due to a combination of climatic changes and ecological pressures by humans. Cuddie Springs is central to this debate as it is the only site known in continental Australia where archaeological and megafauna remains co-occur. We have analysed more than 60 bones and teeth from the site by laser ablation ICP-MS to determine U, and Th concentrations and distributions, and those with sufficiently high U concentrations were analysed for U-series isotopes. Twenty-nine teeth were analysed by ESR. These new results, as well as previously published geochronological data, contradict the hypothesis that the clastic sediments of Stratigraphic Unit 6 (SU6) are in primary context with the faunal, archaeological and other materials found in SU6, and that all have ages consistent with the optically stimulated luminescence (OSL) estimates of 30-36 ka. These young OSL results were used to argue for a relatively recent age of the extinct fauna. Our results imply that SU6 is either significantly older than the OSL results, or that a large fraction of the faunal material and the charcoal found in SU6 was derived from older, lateral deposits. Our U and Th laser ablation ICPMS results as well as the REE profiles reported by Trueman et al. [2008. Comparing rates of recystallisation and the potential for preservation of biomolecules from the distribution of trace elements in fossil bones. C.R. Palevol. General Paleontology (Taphonomy and Fossilization) 7, 145-158] contradict the interpretation of previously reported rare earth element compositions of bones, and the argument based thereon for the primary context of faunal material and clastic sediments in SU6 layers.

  11. Late Pleistocene dune activity in the central Great Plains, USA

    USGS Publications Warehouse

    Mason, J.A.; Swinehart, J.B.; Hanson, P.R.; Loope, D.B.; Goble, R.J.; Miao, X.; Schmeisser, R.L.

    2011-01-01

    Stabilized dunes of the central Great Plains, especially the megabarchans and large barchanoid ridges of the Nebraska Sand Hills, provide dramatic evidence of late Quaternary environmental change. Episodic Holocene dune activity in this region is now well-documented, but Late Pleistocene dune mobility has remained poorly documented, despite early interpretations of the Sand Hills dunes as Pleistocene relicts. New optically stimulated luminescence (OSL) ages from drill cores and outcrops provide evidence of Late Pleistocene dune activity at sites distributed across the central Great Plains. In addition, Late Pleistocene eolian sands deposited at 20-25 ka are interbedded with loess south of the Sand Hills. Several of the large dunes sampled in the Sand Hills clearly contain a substantial core of Late Pleistocene sand; thus, they had developed by the Late Pleistocene and were fully mobile at that time, although substantial sand deposition and extensive longitudinal dune construction occurred during the Holocene. Many of the Late Pleistocene OSL ages fall between 17 and 14 ka, but it is likely that these ages represent only the later part of a longer period of dune construction and migration. At several sites, significant Late Pleistocene or Holocene large-dune migration also probably occurred after the time represented by the Pleistocene OSL ages. Sedimentary structures in Late Pleistocene eolian sand and the forms of large dunes potentially constructed in the Late Pleistocene both indicate sand transport dominated by northerly to westerly winds, consistent with Late Pleistocene loess transport directions. Numerical modeling of the climate of the Last Glacial Maximum has often yielded mean monthly surface winds southwest of the Laurentide Ice Sheet that are consistent with this geologic evidence, despite strengthened anticyclonic circulation over the ice sheet. Mobility of large dunes during the Late Pleistocene on the central Great Plains may have been the result of cold, short growing seasons with relatively low precipitation and low atmospheric CO2 that increased plant moisture stress, limiting the ability of vegetation to stabilize active dune sand. The apparent coexistence of large mobile dunes with boreal forest taxa suggests a Late Pleistocene environment with few modern analogs. ?? 2011 Elsevier Ltd.

  12. Image reconstruction algorithm for optically stimulated luminescence 2D dosimetry using laser-scanned Al2O3:C and Al2O3:C,Mg films

    NASA Astrophysics Data System (ADS)

    Ahmed, M. F.; Schnell, E.; Ahmad, S.; Yukihara, E. G.

    2016-10-01

    The objective of this work was to develop an image reconstruction algorithm for 2D dosimetry using Al2O3:C and Al2O3:C,Mg optically stimulated luminescence (OSL) films imaged using a laser scanning system. The algorithm takes into account parameters associated with detector properties and the readout system. Pieces of Al2O3:C films (~8 mm  ×  8 mm  ×  125 µm) were irradiated and used to simulate dose distributions with extreme dose gradients (zero and non-zero dose regions). The OSLD film pieces were scanned using a custom-built laser-scanning OSL reader and the data obtained were used to develop and demonstrate a dose reconstruction algorithm. The algorithm includes corrections for: (a) galvo hysteresis, (b) photomultiplier tube (PMT) linearity, (c) phosphorescence, (d) ‘pixel bleeding’ caused by the 35 ms luminescence lifetime of F-centers in Al2O3, (e) geometrical distortion inherent to Galvo scanning system, and (f) position dependence of the light collection efficiency. The algorithm was also applied to 6.0 cm  ×  6.0 cm  ×  125 μm or 10.0 cm  ×  10.0 cm  ×  125 µm Al2O3:C and Al2O3:C,Mg films exposed to megavoltage x-rays (6 MV) and 12C beams (430 MeV u-1). The results obtained using pieces of irradiated films show the ability of the image reconstruction algorithm to correct for pixel bleeding even in the presence of extremely sharp dose gradients. Corrections for geometric distortion and position dependence of light collection efficiency were shown to minimize characteristic limitations of this system design. We also exemplify the application of the algorithm to more clinically relevant 6 MV x-ray beam and a 12C pencil beam, demonstrating the potential for small field dosimetry. The image reconstruction algorithm described here provides the foundation for laser-scanned OSL applied to 2D dosimetry.

  13. SU-E-T-178: Optically Stimulated Luminescence (OSL) Dosimetry: A Study of A-Al2O3:C Assessed by PENELOPE Monte Carlo Simulation.

    PubMed

    Nicolucci, P; Schuch, F

    2012-06-01

    To use the Monte Carlo code PENELOPE to study attenuation and tissue equivalence properties of a-Al2O3:C for OSL dosimetry. Mass attenuation coefficients of α-Al2O3 and α-Al2O3:C with carbon percent weight concentrations from 1% to 150% were simulated with PENELOPE Monte Carlo code and compared to mass attenuation coefficients from soft tissue for photon beams ranging from 50kV to 10MV. Also, the attenuation of primary photon beams of 6MV and 10MV and the generation of secondary electrons by α-Al2O3 :C dosimeters positioned on the entrance surface of a water phantom were studied. A difference of up to 90% was found in the mass attenuation coefficient between the pure \\agr;-A12O3 and the material with 150% weight concentration of dopant at 1.5 keV, corresponding to the K-edge photoelectric absorption of aluminum. However for energies above 80 keV the concentration of carbon does not affect the mass attenuation coefficient and the material presents tissue equivalence for the beams studied. The ratio between the mass attenuation coefficients for \\agr-A12O3:C and for soft tissue are less than unit due to the higher density of the \\agr-A12O3 (2.12 g/cm s ) and its tissue equivalence diminishes to lower concentrations of carbon and for lower energies due to the relation of the radiation interaction effects with atomic number. The larger attenuation of the primary photon beams by the dosimeter was 16% at 250 keV and the maximum increase in secondary electrons fluence to the entrance surface of the phantom was found as 91% at 2MeV. The use of the OSL dosimeters in radiation therapy can be optimized by use of PENELOPE Monte Carlo simulation to provide a study of the attenuation and response characteristics of the material. © 2012 American Association of Physicists in Medicine.

  14. The chronostratigraphy of the Haua Fteah cave (Cyrenaica, northeast Libya) - Optical dating of early human occupation during Marine Isotope Stages 4, 5 and 6.

    PubMed

    Jacobs, Zenobia; Li, Bo; Farr, Lucy; Hill, Evan; Hunt, Chris; Jones, Sacha; Rabett, Ryan; Reynolds, Tim; Roberts, Richard G; Simpson, David; Barker, Graeme

    2017-04-01

    The paper presents the results of optical dating of potassium-rich feldspar grains obtained from the Haua Fteah cave in Cyrenaica, northeast Libya, focussing on the chronology of the Deep Sounding excavated by Charles McBurney in the 1950s and re-excavated recently. Samples were also collected from a 1.25 m-deep trench (Trench S) excavated during the present project below the basal level of the Deep Sounding. Optically stimulated luminescence (OSL) data sets for multi-grain, single aliquots of quartz for samples from the Middle Trench were previously published. Re-analyses of these OSL data confirm significant variation in the dose saturation levels of the quartz signal, but allow the most robust OSL ages to be determined for comparison with previous age estimates and with those obtained in this study for potassium-rich feldspars from the Deep Sounding. The latter indicate that humans may have started to visit the cave as early as ∼150 ka ago, but that major use of the cave occurred during MIS 5, with the accumulation of the Deep Sounding sediments. Correlations between optical ages and episodes of "Pre-Aurignacian" artefact discard indicate that human use of the cave during MIS 5 was highly intermittent. The earliest phases of human activity appear to have occurred during interstadial conditions (5e and 5c), with a later phase of lithic discard associated with more stadial conditions, possibly MIS 5b. We argue that the "Pre-Aurignacian" assemblage can probably be linked with modern humans, like the succeeding "Levalloiso-Mousterian" assemblage; two modern human mandibles associated with the latter are associated with a modelled age of 73-65 ka. If this attribution is correct, then the new chronology implies that modern humans using "Pre-Aurignacian" technologies were in Cyrenaica as early as modern humans equipped with "Aterian" technologies were in the Maghreb, raising new questions about variability among lithic technologies during the initial phases of modern human dispersals into North Africa. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. A new luminescence dating chronology for the Rhafas cave site (NE Morocco): Insights into Palaeolithic human cultural change under varying palaeoenvironmental conditions in the Maghreb

    NASA Astrophysics Data System (ADS)

    Dörschner, Nina; Fitzsimmons, Kathryn E.; Ditchfield, Peter; McLaren, Sue J.; Steele, Teresa E.; Zielhofer, Christoph; McPherron, Shannon P.; Bouzouggar, Abdeljalil; Hublin, Jean-Jacques

    2016-04-01

    Archaeological sites in northern Africa provide a rich record that is of increasing importance for current debates relating to the origins of modern human behaviour and to Out of Africa human dispersal events. Particular interest is placed on the cultural transition between the North African Middle Stone Age (MSA) and Late Stone Age (LSA), and the need for accurately defined chronologies, however the timing and nature of Palaeolithic human behaviour and dispersal across north-western Africa (the Maghreb) and potential correlation with environmental conditions remain poorly understood. The inland cave site of Rhafas (Morocco) preserves a long stratified sequence providing valuable chronological information about cultural changes in the Maghreb spanning the North African MSA through to the Neolithic. In this study, we apply optically stimulated luminescence (OSL) dating on sand-sized quartz grains to the cave deposits of Rhafas as well as to a section on the terrace in front of the cave entrance. Single grain OSL dating reliably constrains the timing of technocomplexes beyond the limits of radiocarbon by directly dating sediment associated with archaeological traces. We combine OSL dating with multi-proxy geological investigations (XRF, grain size analyses, stable isotopes, thin sections) to investigate site formation processes and reconstruct palaeoenvironmental conditions during human occupation phases at Rhafas. Our results indicate that the occupation of the site started at least in MIS 6 during a phase of relatively arid environmental conditions. Climatic amelioration after c.140 ka is associated with a change in sediment geochemistry at the site, most likely linked to a change in sediment source due to shifting wind directions. Tanged pieces - typical for the classical Aterian technocomplex - start to occur in the archaeological sequence in MIS 5, consistent with previously published chronological data from the Maghreb. From 55 ka, climatic conditions were sufficiently humid for the pedogenic cementation of Rhafas sediments by carbonates, resulting in the formation of a duricrust several centimetres thick. Deposits from the last glacial period are associated with LSA technocomplexes and fall within previously established chronologies from the Maghreb.

  16. Paleoenvironmental change in central Chile as inferred from OSL dating of ancient coastal sand dunes

    NASA Astrophysics Data System (ADS)

    Andrade, Belisario; Garcia, Juan L.; Lüthgens, Christopher; Fiebig, Markus

    2013-04-01

    To present day, the climatic and geographic expression of glacials and interglacials in the semiarid coast of central Chile remains unclear. The lack of well dated paleoclimatic records has up to now precluded firm conclusions whether maximum glacials evident in the Andes mountain range probably coincide with wetter (e.g., pluvials) or drier conditions at the coast. The natural region locally known as "Norte Chico" represents a transitional semiarid area between the extreme Atacama Desert to the North and the wetter, Mediterranean-like type of climate, to the South. In this semiarid region of Chile several generations of eolian sand dunes, some of them separated by paleosoils, have been preserved. In addition to the occurrence of paleosoils, thick debris flow deposits in some places overly ancient dune bodies, likely indicating significant environmental changes during the formation of these archives. However, the exact timing of these processes within the mid to late Pleistocene and Holocene is still unclear. A key aspect is that some of the ancient dunes are recently hanging above rocky coastlines, where no supply of sand exists today, likely implying their formation during a lower than present, probably glacio-eustatically induced sea level. The location of the research area in a key mid-latitude region of the eastern Pacific in combination with the preserved landform record offers a chance to reconstruct climatic shifts during the Quaternary by studying the variability of morphogenetic conditions throughout time, in order to promote knowledge about possible forcing factors driving climatic variability. Within this pilot study, samples for optically stimulated luminescence (OSL) dating were taken from three different stratigraphic sections that denote a complex environmental variability as indicated by paleosoils and debris flow units intercalated in ancient sand dunes. First dating results inferred from OSL measurements using a post-IR IRSL (pIRIR) protocol for the dating of feldspar will be presented at the conference. Within this project we aim to establish a geochronological framework for the described sedimentary archives in order to unravel their local and regional paleoenvironmental context.

  17. Sedimentary Evolution of Marginal Ganga Foreland Basin during the Late Pleistocene

    NASA Astrophysics Data System (ADS)

    Ghosh, R.; Srivastava, P.; Shukla, U. K.

    2017-12-01

    Ganga foreland basin, an asymmetrical basin, was formed as result of plate-plate collision during middle Miocene. A major thrust event occurred during 500 ka when upper Siwalik sediments were uplifted and the modern Ganga foreland basin shifted towards craton, making a more wide and deep basin. The more distal part of this basin, south of axial river Yamuna, records fluvial sedimentary packages that helps to understand dynamics of peripheral bulge during the late Quaternary. Sedimentary architecture in conjunction with chemical index of alteration (CIA), paleocurrent direction and optically stimulated dating (OSL) from 19 stratigraphic sections helped reconstructing the variations in depositional environments vis-à-vis climate change and peripheral bulge tectonics. Three major units (i) paleosol; (ii) cratonic gravel; (iii) interfluve succession were identified. The lower unit-I showing CIA values close to 70-80 and micro-morphological features of moderately well-developed pedogenic unit that shows development of calcrete, rhizoliths, and mineralized organic matter in abundance. This is a regional paleosols unit and OSL age bracketed 200 ka. This is unconformably overlain by unit-II, a channelized gravel composed of sub-angular to sub-rounded clasts of granite, quartz, quartzite, limestone and calcrete. The gravel have low CIA value up to 55, rich in vertebrate fossil assemblages and mean paleocurrent vector direction is NE, which suggesting deposition by a fan of a river draining craton into foreland. This unit is dated between 100 ka and 54 ka. The top unit-III, interfluve succession of 10-15 m thick is composed of dark and light bands of sheet like deposit of silty clay to clayey silt comprises sand lenses of red to grey color and displaying top most OSL age is 12 ka. The basal mature paleosol signifies a humid climate developed under low subsidence rate at >100 ka. After a hiatus represented by pedogenic surface deposition of unit-II (gravel) suggests uplift and increased relief in the peripheral bulge region resulting into large flux of coarse sediments from craton. This was accompanied by humid climate and braided rivers forming a craton derived north propagating fans. Similar depositional setup at the base Siwalik is termed as peripheral bulge unconformity.

  18. Development of a clinically validated bulk failure test for ceramic crowns.

    PubMed

    Kelly, J Robert; Rungruanganunt, Patchnee; Hunter, Ben; Vailati, Francesca

    2010-10-01

    Traditional testing of ceramic crowns creates a stress state and damage modes that differ greatly from those seen clinically. There is a need to develop and communicate an in vitro testing protocol that is clinically valid. The purpose of this study was to develop an in vitro failure test for ceramic single-unit prostheses that duplicates the failure mechanism and stress state observed in clinically failed prostheses. This article first compares characteristics of traditional load-to-failure tests of ceramic crowns with the growing body of evidence regarding failure origins and stress states at failure from the examination of clinically failed crowns, finite element analysis (FEA), and data from clinical studies. Based on this analysis, an experimental technique was systematically developed and test materials were identified to recreate key aspects of clinical failure in vitro. One potential dentin analog material (an epoxy filled with woven glass fibers; NEMA grade G10) was evaluated for elastic modulus in blunt contact and for bond strength to resin cement as compared to hydrated dentin. Two bases with different elastic moduli (nickel chrome and resin-based composite) were tested for influence on failure loads. The influence of water during storage and loading (both monotonic and cyclic) was examined. Loading piston materials (G10, aluminum, stainless steel) and piston designs were varied to eliminate Hertzian cracking and to improve performance. Testing was extended from a monolayer ceramic (leucite-filled glass) to a bilayer ceramic system (glass-infiltrated alumina). The influence of cyclic rate on mean failure loads was examined (2 Hz, 10 Hz, 20 Hz) with the extremes compared statistically (t test; α=.05). Failure loads were highly influenced by base elastic modulus (t test; P<.001). Cyclic loading while in water significantly decreased mean failure loads (1-way ANOVA; P=.003) versus wet storage/dry cycling (350 N vs. 1270 N). G10 was not significantly different from hydrated dentin in terms of blunt contact elastic behavior or resin cement bond strength. Testing was successful with the bilayered ceramic, and the cycling rate altered mean failure loads only slightly (approximately 5%). Test methods and materials were developed to validly simulate many aspects of clinical failure. Copyright © 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  19. NASA Structural Analysis Report on the American Airlines Flight 587 Accident - Local Analysis of the Right Rear Lug

    NASA Technical Reports Server (NTRS)

    Raju, Ivatury S; Glaessgen, Edward H.; Mason, Brian H; Krishnamurthy, Thiagarajan; Davila, Carlos G

    2005-01-01

    A detailed finite element analysis of the right rear lug of the American Airlines Flight 587 - Airbus A300-600R was performed as part of the National Transportation Safety Board s failure investigation of the accident that occurred on November 12, 2001. The loads experienced by the right rear lug are evaluated using global models of the vertical tail, local models near the right rear lug, and a global-local analysis procedure. The right rear lug was analyzed using two modeling approaches. In the first approach, solid-shell type modeling is used, and in the second approach, layered-shell type modeling is used. The solid-shell and the layered-shell modeling approaches were used in progressive failure analyses (PFA) to determine the load, mode, and location of failure in the right rear lug under loading representative of an Airbus certification test conducted in 1985 (the 1985-certification test). Both analyses were in excellent agreement with each other on the predicted failure loads, failure mode, and location of failure. The solid-shell type modeling was then used to analyze both a subcomponent test conducted by Airbus in 2003 (the 2003-subcomponent test) and the accident condition. Excellent agreement was observed between the analyses and the observed failures in both cases. From the analyses conducted and presented in this paper, the following conclusions were drawn. The moment, Mx (moment about the fuselage longitudinal axis), has significant effect on the failure load of the lugs. Higher absolute values of Mx give lower failure loads. The predicted load, mode, and location of the failure of the 1985-certification test, 2003-subcomponent test, and the accident condition are in very good agreement. This agreement suggests that the 1985-certification and 2003- subcomponent tests represent the accident condition accurately. The failure mode of the right rear lug for the 1985-certification test, 2003-subcomponent test, and the accident load case is identified as a cleavage-type failure. For the accident case, the predicted failure load for the right rear lug from the PFA is greater than 1.98 times the limit load of the lugs. I.

  20. Structural Analysis of the Right Rear Lug of American Airlines Flight 587

    NASA Technical Reports Server (NTRS)

    Raju, Ivatury S.; Glaessgen, Edward H.; Mason, Brian H.; Krishnamurthy, Thiagarajan; Davila, Carlos G.

    2006-01-01

    A detailed finite element analysis of the right rear lug of the American Airlines Flight 587 - Airbus A300-600R was performed as part of the National Transportation Safety Board s failure investigation of the accident that occurred on November 12, 2001. The loads experienced by the right rear lug are evaluated using global models of the vertical tail, local models near the right rear lug, and a global-local analysis procedure. The right rear lug was analyzed using two modeling approaches. In the first approach, solid-shell type modeling is used, and in the second approach, layered-shell type modeling is used. The solid-shell and the layered-shell modeling approaches were used in progressive failure analyses (PFA) to determine the load, mode, and location of failure in the right rear lug under loading representative of an Airbus certification test conducted in 1985 (the 1985-certification test). Both analyses were in excellent agreement with each other on the predicted failure loads, failure mode, and location of failure. The solid-shell type modeling was then used to analyze both a subcomponent test conducted by Airbus in 2003 (the 2003-subcomponent test) and the accident condition. Excellent agreement was observed between the analyses and the observed failures in both cases. The moment, Mx (moment about the fuselage longitudinal axis), has significant effect on the failure load of the lugs. Higher absolute values of Mx give lower failure loads. The predicted load, mode, and location of the failure of the 1985- certification test, 2003-subcomponent test, and the accident condition are in very good agreement. This agreement suggests that the 1985-certification and 2003-subcomponent tests represent the accident condition accurately. The failure mode of the right rear lug for the 1985-certification test, 2003-subcomponent test, and the accident load case is identified as a cleavage-type failure. For the accident case, the predicted failure load for the right rear lug from the PFA is greater than 1.98 times the limit load of the lugs.

  1. Comprehensive analysis of cochlear implant failure: usefulness of clinical symptom-based algorithm combined with in situ integrity testing.

    PubMed

    Yamazaki, Hiroshi; O'Leary, Stephen; Moran, Michelle; Briggs, Robert

    2014-04-01

    Accurate diagnosis of cochlear implant failures is important for management; however, appropriate strategies to assess possible device failures are not always clear. The purpose of this study is to understand correlation between causes of device failure and the presenting clinical symptoms as well as results of in situ integrity testing and to propose effective strategies for diagnosis of device failure. Retrospective case review. Cochlear implant center at a tertiary referral hospital. Twenty-seven cases with suspected device failure of Cochlear Nucleus systems (excluding CI512 failures) on the basis of deterioration in auditory perception from January 2000 to September 2012 in the Melbourne cochlear implant clinic. Clinical presentations and types of abnormalities on in situ integrity testing were compared with modes of device failure detected by returned device analysis. Sudden deterioration in auditory perception was always observed in cases with "critical damage": either fracture of the integrated circuit or most or all of the electrode wires. Subacute or gradually progressive deterioration in auditory perception was significantly associated with a more limited number of broken electrode wires. Cochlear implant mediated auditory and nonauditory symptoms were significantly associated with an insulation problem. An algorithm based on the time course of deterioration in auditory perception and cochlear implant-mediated auditory and nonauditory symptoms was developed on the basis of these retrospective analyses, to help predict the mode of device failure. In situ integrity testing, which included close monitoring of device function in routine programming sessions as well as repeating the manufacturer's integrity test battery, was sensitive enough to detect malfunction in all suspected device failures, and each mode of device failure showed a characteristic abnormality on in situ integrity testing. Our clinical manifestation-based algorithm combined with in situ integrity testing may be useful for accurate diagnosis and appropriate management of device failure. Close monitoring of device function in routine programming sessions as well as repeating the manufacturer's integrity test battery is important if the initial in situ integrity testing is inconclusive because objective evidence of failure in the implanted device is essential to recommend explantation/reimplantation.

  2. Quantitative Approach to Failure Mode and Effect Analysis for Linear Accelerator Quality Assurance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Daniel, Jennifer C., E-mail: jennifer.odaniel@duke.edu; Yin, Fang-Fang

    Purpose: To determine clinic-specific linear accelerator quality assurance (QA) TG-142 test frequencies, to maximize physicist time efficiency and patient treatment quality. Methods and Materials: A novel quantitative approach to failure mode and effect analysis is proposed. Nine linear accelerator-years of QA records provided data on failure occurrence rates. The severity of test failure was modeled by introducing corresponding errors into head and neck intensity modulated radiation therapy treatment plans. The relative risk of daily linear accelerator QA was calculated as a function of frequency of test performance. Results: Although the failure severity was greatest for daily imaging QA (imaging vsmore » treatment isocenter and imaging positioning/repositioning), the failure occurrence rate was greatest for output and laser testing. The composite ranking results suggest that performing output and lasers tests daily, imaging versus treatment isocenter and imaging positioning/repositioning tests weekly, and optical distance indicator and jaws versus light field tests biweekly would be acceptable for non-stereotactic radiosurgery/stereotactic body radiation therapy linear accelerators. Conclusions: Failure mode and effect analysis is a useful tool to determine the relative importance of QA tests from TG-142. Because there are practical time limitations on how many QA tests can be performed, this analysis highlights which tests are the most important and suggests the frequency of testing based on each test's risk priority number.« less

  3. Carbon Fiber Strand Tensile Failure Dynamic Event Characterization

    NASA Technical Reports Server (NTRS)

    Johnson, Kenneth L.; Reeder, James

    2016-01-01

    There are few if any clear, visual, and detailed images of carbon fiber strand failures under tension useful for determining mechanisms, sequences of events, different types of failure modes, etc. available to researchers. This makes discussion of physics of failure difficult. It was also desired to find out whether the test article-to-test rig interface (grip) played a part in some failures. These failures have nothing to do with stress rupture failure, thus representing a source of waste for the larger 13-00912 investigation into that specific failure type. Being able to identify or mitigate any competing failure modes would improve the value of the 13-00912 test data. The beginnings of the solution to these problems lay in obtaining images of strand failures useful for understanding physics of failure and the events leading up to failure. Necessary steps include identifying imaging techniques that result in useful data, using those techniques to home in on where in a strand and when in the sequence of events one should obtain imaging data.

  4. Failure analysis of a tool steel torque shaft

    NASA Technical Reports Server (NTRS)

    Reagan, J. R.

    1981-01-01

    A low design load drive shaft used to deliver power from an experimental exhaust heat recovery system to the crankshaft of an experimental diesel truck engine failed during highway testing. An independent testing laboratory analyzed the failure by routine metallography and attributed the failure to fatigue induced by a banded microstructure. Visual examination by NASA of the failed shaft plus the knowledge of the torsional load that it carried pointed to a 100 percent ductile failure with no evidence of fatigue. Scanning electron microscopy confirmed this. Torsional test specimens were produced from pieces of the failed shaft and torsional overload testing produced identical failures to that which had occurred in the truck engine. This pointed to a failure caused by a high overload and although the microstructure was defective it was not the cause of the failure.

  5. Estimation procedures to measure and monitor failure rates of components during thermal-vacuum testing

    NASA Technical Reports Server (NTRS)

    Williams, R. E.; Kruger, R.

    1980-01-01

    Estimation procedures are described for measuring component failure rates, for comparing the failure rates of two different groups of components, and for formulating confidence intervals for testing hypotheses (based on failure rates) that the two groups perform similarly or differently. Appendix A contains an example of an analysis in which these methods are applied to investigate the characteristics of two groups of spacecraft components. The estimation procedures are adaptable to system level testing and to monitoring failure characteristics in orbit.

  6. Perception of Motion in Statistically-Defined Displays.

    DTIC Science & Technology

    1988-02-15

    motion encoding (Reichardt, 1961; Barlow and Levick , 1963; van Doorn and Koenderink, 1982a, b ; van de Grind, Koenderink, van Doorn, 1983). A bilocal...stimelu toetini motion onet Lca perception. Psychological Review, 87, 435-469.bo. Barlow H. B . and Levick W. R. (1963) The mechanisms of directionally...REPORT NUMBER(S) 5. MONITORING ORGANIZATIOLA OAT yOSl R 6. NAME OF PERFORMING ORGANIZATION b . OFFICE SYMBOL 7@. NAME OF MONITORING ORGANIZATION (If

  7. Hydrazine Blending and Storage Facility, Interim Response Action Implementation. Final Safety Plan

    DTIC Science & Technology

    1989-08-30

    operators and visitors, will be required to wear a personal hydrazine dosimeter at all times. These will be available from commercial sources and/or the Naval...suspectea or carcinogenic pocen:tal for =an. -- t, :t ha a,,-cn OSL ?:L. Is I pPm or 1.3 mg/m 3 . zo pp=n4p"NIOSI. (1978) hs a oe -nded a ceiling level

  8. Late Quaternary paleoenvironments and paleoclimatic conditions in the distal Andean piedmont, southern Mendoza, Argentina

    NASA Astrophysics Data System (ADS)

    Tripaldi, Alfonsina; Zárate, Marcelo A.; Brook, George A.; Li, Guo-Qiang

    2011-09-01

    The Andean piedmont of Mendoza is a semiarid region covered by extensive and partially vegetated dune fields consisting of mostly inactive aeolian landforms of diverse size and morphology. This paper is focused on the San Rafael plain (SRP) environment, situated in the distal Andean piedmont of Mendoza (34° 30'S), and reports the sedimentology and OSL chronology of two representative exposures of late Quaternary deposits, including their paleoenvironmental and paleoclimatic significance. Eleven facies, including channel, floodplain, fluvio-aeolian interaction, and reworked pyroclastic and aeolian deposits, were described and grouped into two facies associations (FA1 and FA2). FA1 was formed by unconfined sheet flows, minor channelized streams and fluvial-aeolian interaction processes. FA2 was interpreted as aeolian dune and sand-sheet deposits. OSL chronology from the SRP sedimentary record indicates that between ca. 58-39 ka and ca. 36-24 ka (MIS 3), aggradation was governed by ephemeral fluvial processes (FA1) under generally semiarid conditions. During MIS 2, the last glacial maximum (ca. 24-12 ka), a major climatic shift to more arid conditions is documented by significant aeolian activity (FA2) that became the dominant sedimentation process north of the Diamante-Atuel fluvial system. The inferred paleoenvironmental conditions from the SRP sections are in broad agreement with regional evidence.

  9. Imprint of Late Quaternary Climate Change on the Mid-Atlantic Landscape

    NASA Astrophysics Data System (ADS)

    Pavich, M.; Markewich, H.; Newell, W. L.; Litwin, R.; Smoot, J.; Brook, G.

    2009-12-01

    Recent geomorphic, lithostratigraphic, palynologic and chronostratigraphic investigations of the mid-Atlantic region show that much of the modern landscape flanking the Chesapeake Bay and the Potomac River is developed on late Quaternary sediments. These deposits, dated by OSL and 14C, include transgressive marine and estuarine sediments deposited between 120ka and 32ka, and parabolic dunes formed between 32ka and 15ka. The stacked estuarine units were deposited in a subsiding basin as eustatic sea level fell from +7m to -60m. The estuarine units contain pollen that provides evidence for millennial scale climate fluctuations. The dunes formed during the period of rapid expansion of the Laurentide Ice Sheet as sea level fell to -120m. Permafrost features such as frost wedges and periglacial “pots” formed during cold intervals associated with marine oxygen isotope stages 4 and 2. This periglacial climate, along with glacioisostatic adjustments to growth and decay of the Laurentide Ice Sheet, affected landscape processes at least as far south as the Potomac River valley. While many of these features were recognized in earlier mapping and stratigraphic investigations, OSL dating has greatly extended the range of available dates and significantly improved our understanding of the impacts of highly variable periglacial climate on this region.

  10. A geochronologic framework for the Ziegler Reservoir fossil site, Snowmass Village, Colorado

    USGS Publications Warehouse

    Mahan, Shannon; Gray, Harrison J.; Pigati, Jeffrey S.; Wilson, Jim; Lifton, Nathaniel A.; Paces, James B.; Blaauw, Maarten

    2014-01-01

    The Ziegler Reservoir fossil site near Snowmass Village, Colorado, provides a unique opportunity to reconstruct high-altitude paleoenvironmental conditions in the Rocky Mountains during the last interglacial period. We used four different techniques to establish a chronological framework for the site. Radiocarbon dating of lake organics, bone collagen, and shell carbonate, and in situ cosmogenic 10Be and 26Al ages on a boulder on the crest of a moraine that impounded the lake suggest that the ages of the sediments that hosted the fossils are between ~ 140 ka and > 45 ka. Uranium-series ages of vertebrate remains generally fall within these bounds, but extremely low uranium concentrations and evidence of open-system behavior limit their utility. Optically stimulated luminescence (OSL) ages (n = 18) obtained from fine-grained quartz maintain stratigraphic order, were replicable, and provide reliable ages for the lake sediments. Analysis of the equivalent dose (DE) dispersion of the OSL samples showed that the sediments were fully bleached prior to deposition and low scatter suggests that eolian processes were likely the dominant transport mechanism for fine-grained sediments into the lake. The resulting ages show that the fossil-bearing sediments span the latest part of marine isotope stage (MIS) 6, all of MIS 5 and MIS 4, and the earliest part of MIS 3.

  11. Holocene aeolian activity in the Gonghe Basin, north-eastern Tibetan Plateau

    NASA Astrophysics Data System (ADS)

    Stauch, Georg; Lai, Zhongping; Lehmkuhl, Frank; Schulte, Philipp

    2016-04-01

    The Gonghe Basin is located on the north-eastern edge of Tibetan Plateau and has a mean altitude of 3000 m asl. With a size of 20.000 km² it is the largest intramontane Basin on the north-eastern Plateau. The well-studied Qinghai Basin is situated north of the Basin, while the drier central Plateau is further south-west. Previous research indicated an early onset of the aeolian accumulation in the Qinghai Basin at around 18 ka while in the areas further to the south-west aeolian archives date back only to the beginning of the Holocene. First new OSL ages from aeolian sand and loess indicate a intermediate timing of the aeolian accumulation in the Gonghe Basin at the transition from the late glacial to the Holocene. Late glacial and early Holocene ages of aeolian sediments were hitherto associated with wetter climate conditions caused by the strengthening of the Asian summer monsoon. Higher moisture availability resulted in an increased vegetation cover, leading to the permanent stabilization of the aeolian sediments. Under glacial climate conditions a constant remobilization of the sediments can be assumed. The new OSL ages from the Gonghe Basin indicate a progressive shift of the monsoonal strength in westward directions during the late glacial until the early Holocene.

  12. Characterization of aluminum oxide doped with carbon and magnesium for radiation detection

    NASA Astrophysics Data System (ADS)

    Rodriguez, Matthew Gorman

    Scope and Method of Study. A general characterization of the dosimetric properties of Al2O3:C,Mg. This included the thermoluminescence (TL) optically stimulated luminescence (OSL), radioluminescence (RL) and scintillation characteristics of Al2O3:C,Mg compared to Al2O3:C. Findings and Conclusions. The presence of aggregate defects as well as an increased F+-center concentration leads to the behavior of Al2O3:C,Mg being far more complex than Al2O3:C. The main TL peak is shifted to a lower temperature and narrower when compared to the main TL peak of Al 2O3:C. The OSL curves of Al2O3:C,Mg decay faster than Al2O3:C. Al2O3:C,Mg shows smaller dependence on the RL sensitivity as a function of dose, thus reducing the dynamic behavior of the RL signal associated with Al2O 3:C. Al2O3:C,Mg also has fast luminescence centers with lifetimes <100 ns. Finally, Annealing Al2O 3:C,Mg to 900°C would appear to increase the number of F+ and F recombination centers while destroying the aggregate defects present in the material.

  13. High resolution luminescence chronology for Xiashu Loess deposits of Southeastern China

    NASA Astrophysics Data System (ADS)

    Yi, Shuangwen; Li, Xusheng; Han, Zhiyong; Lu, Huayu; Liu, Jinfeng; Wu, Jiang

    2018-04-01

    Loess deposits in Xiashu are representative of such deposits in Southeastern China that are mainly distributed in the middle and lower reaches of the Yangtze River valley. These loess-paleosol sequences provide a key archive of past climate change in humid, subtropical regions. However, the ages of the sequences are not well constrained. In this study, the standard quartz single-aliquot regenerative (SAR) dose optically stimulated luminescence (OSL) and K-feldspar post-infrared infrared stimulated luminescence (post-IR IRSL; pIRIR290) methods are used to date two loess sequences in Nanjing region. Our results show that quartz SAR OSL and K-feldspar pIRIR290 ages are more or less indistinguishable from one another up to ∼50 ka. Beyond this age, the K-feldspar pIRIR ages increased systematically with deposition depth, agreeing well with the expected ages as far as ∼200 ka. On the basis of a fully independently-dated timescale, we are therefore able to propose, for the first time, a new age model for the Xiashu Loess deposits accumulated since the penultimate interglacial period. Using our newly obtained luminescence dating ages, we observe a marked difference between the loess accumulation rates in the two sequences, potentially forced by regional depositional processes and loess preservation.

  14. Fluvial system response to Late Devensian (Weichselian) aridity, Baston, Lincolnshire, England

    NASA Astrophysics Data System (ADS)

    Briant, Rebecca M.; Coope, G. Russell; Preece, Richard C.; Keen, David H.; Boreham, Steve; Griffiths, Huw I.; Seddon, Mary B.; Gibbard, Philip L.

    2004-07-01

    Little is known about the impact of Late Devensian (Weichselian) aridity on lowland British landscapes, largely because they lack the widespread coversand deposits of the adjacent continent. The concentration of large interformational ice-wedge casts in the upper part of many Devensian fluvial sequences suggests that fluvial activity may have decreased considerably during this time. The development of optically stimulated luminescence (OSL) dating enables this period of ice-wedge cast formation to be constrained for the first time in eastern England, where a marked horizon of ice-wedge casts is found between two distinctive dateable facies associations. Contrasts between this horizon and adjacent sediments show clear changes in environment and fluvial system behaviour in response to changing water supply, in line with palaeontological evidence. In addition to providing chronological control on the period of ice-wedge formation, the study shows good agreement of the radiocarbon and OSL dating techniques during the Middle and Late Devensian, with direct comparison of these techniques beyond 15 000 yr for the first time in Britain. It is suggested that aridity during the Late Devensian forced a significant decrease in fluvial activity compared with preceding and following periods, initiating a system with low peak flows and widespread permafrost development. Copyright

  15. Epidermis architecture and material properties of the skin of four snake species

    PubMed Central

    Klein, Marie-Christin G.; Gorb, Stanislav N.

    2012-01-01

    On the basis of structural and experimental data, it was previously demonstrated that the snake integument consists of a hard, robust, inflexible outer surface (Oberhäutchen and β-layer) and softer, flexible inner layers (α-layers). It is not clear whether this phenomenon is a general adaptation of snakes to limbless locomotion or only to specific conditions, such as habitat and locomotion. The aim of the present study was to compare the structure and material properties of the outer scale layers (OSLs) and inner scale layers (ISLs) of the exuvium epidermis in four snake species specialized to live in different habitats: Lampropeltis getula californiae (terrestrial), Epicrates cenchria cenchria (generalist), Morelia viridis (arboreal) and Gongylophis colubrinus (sand-burrowing). Scanning electron microscopy (SEM) of skin cross sections revealed a strong variation in the epidermis structure between species. The nanoindentation experiments clearly demonstrated a gradient of material properties along the epidermis in the integument of all the species studied. The presence of such a gradient is a possible adaptation to locomotion and wear minimization on natural substrates. In general, the difference in both the effective elastic modulus and hardness of the OSL and ISL between species was not large compared with the difference in epidermis thickness and architecture. PMID:22896567

  16. Investigating failure behavior and origins under supposed "shear bond" loading.

    PubMed

    Sultan, Hassam; Kelly, J Robert; Kazemi, Reza B

    2015-07-01

    This study evaluated failure behavior when resin-composite cylinders bonded to dentin fractured under traditional "shear" testing. Failure was assessed by scaling of failure loads to changes in cylinder radii and fracture surface analysis. Three stress models were examined including failure by: bonded area; flat-on-cylinder contact; and, uniformly-loaded, cantilevered-beam. Nine 2-mm dentin occlusal dentin discs for each radii tested were embedded in resin and bonded to resin-composite cylinders; radii (mm)=0.79375; 1.5875; 2.38125; 3.175. Samples were "shear" tested at 1.0mm/min. Following testing, disks were finished with silicone carbide paper (240-600grit) to remove residual composite debris and tested again using different radii. Failure stresses were calculated for: "shear"; flat-on-cylinder contact; and, bending of a uniformly-loaded cantilevered beam. Stress equations and constants were evaluated for each model. Fracture-surface analysis was performed. Failure stresses calculated as flat-on-cylinder contact scaled best with its radii relationship. Stress equation constants were constant for failure from the outside surface of the loaded cylinders and not with the bonded surface area or cantilevered beam. Contact failure stresses were constant over all specimen sizes. Fractography reinforced that failures originated from loaded cylinder surface and were unrelated to the bonded surface area. "Shear bond" testing does not appear to test the bonded interface. Load/area "stress" calculations have no physical meaning. While failure is related to contact stresses, the mechanism(s) likely involve non-linear damage accumulation, which may only indirectly be influenced by the interface. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  17. Test effectiveness study report: An analytical study of system test effectiveness and reliability growth of three commercial spacecraft programs

    NASA Technical Reports Server (NTRS)

    Feldstein, J. F.

    1977-01-01

    Failure data from 16 commercial spacecraft were analyzed to evaluate failure trends, reliability growth, and effectiveness of tests. It was shown that the test programs were highly effective in ensuring a high level of in-orbit reliability. There was only a single catastrophic problem in 44 years of in-orbit operation on 12 spacecraft. The results also indicate that in-orbit failure rates are highly correlated with unit and systems test failure rates. The data suggest that test effectiveness estimates can be used to guide the content of a test program to ensure that in-orbit reliability goals are achieved.

  18. Lox/Gox related failures during Space Shuttle Main Engine development

    NASA Technical Reports Server (NTRS)

    Cataldo, C. E.

    1981-01-01

    Specific rocket engine hardware and test facility system failures are described which were caused by high pressure liquid and/or gaseous oxygen reactions. The failures were encountered during the development and testing of the space shuttle main engine. Failure mechanisms are discussed as well as corrective actions taken to prevent or reduce the potential of future failures.

  19. Synchrotron generated X-ray Excited Optical Luminescence (XEOL) from Quartz

    NASA Astrophysics Data System (ADS)

    King, Georgina; Finch, Adrian; Robinson, Ruth

    2010-05-01

    Quartz is the preferred mineral for optically stimulated luminescence (OSL) dating, due to its well constrained behaviour as a radiation dosimeter. However, despite the plethora of successful quartz OSL applications, no solution has been found to the problem that some quartz luminesce more brightly than others, which has limited the application of OSL in certain settings. This has been addressed through examination of the luminescence emission using a variety of excitation techniques and emission spectroscopy. X-ray Excited Optical Luminescence (XEOL) is luminescence excited by x-rays produced by a synchrotron. XEOL analyses were conducted upon a suite of quartz samples at Diamond, Great Britain, which had previously been analysed with Ionoluminescence (IL), at Sussex University. The samples were selected to include quartz of both poor and excellent OSL sensitivities. Therefore, two Scottish glacial outwash samples prepared at St Andrews, and a calibration quartz sample, prepared at the Risø National Laboratory in Denmark were analysed for these properties respectively. The XEOL emission spectra comprised three major emissions at 3.32, 3.81 and 4.05 eV, and one weaker emission at 1.94 eV in all samples. The calibration quartz sample had the most intense emission by an order of magnitude. Throughout increased exposure to x-rays, the intensity of the UV emission reduced, and an increase in the red (1.94 eV) emission was recorded. The derived XEOL spectra complement the IL spectra obtained previously. The IL spectra were dominated by only two broad emissions at 3.2-3.1 eV and 1.8-1.7 eV. However, throughout the IL experiments a dose dependent effect was also observed, whereby the UV emission was depleted to the benefit of the red with increasing exposure. Furthermore the gradient of the power law relationship between the UV and red emission change with dose is similar for both the IL and XEOL data: at -1.15 and -1.05 respectively for calibration quartz, when plotted on a log-log scale. IL and XEOL are complimentary techniques, as although the radiation dose rate of XEOL is three orders of magnitude greater than that of IL, the total experimental administered dose is similar. This contrast in dose rate is caused by the significant variation is dose per carrier for each technique. Within IL each ion delivers 1E-01 J whereas each photon delivers 1E-15 J in XEOL. It is the much greater flux of photons relative to ions, which makes XEOL the more energetic mode of analysis. Thus these complimentary techniques enable investigation of radiation dose rate, as well as cumulative dose effects. The observed variations in the XEOL and IL derived emission spectra are therefore attributed to the differences in radiation dose rate. The radiation sensitivity of the quartz emission may provide an explanation for the varied luminescence response of different quartz. The quartz luminescence emission thus may not just record the most recent period of irradiation, but rather its entire radiation history.

  20. Quantification of fluvial response to tectonic deformation in the Central Pontides, Turkey; inferences from OSL dating of fluvial terraces

    NASA Astrophysics Data System (ADS)

    McClain, Kevin; Yıldırım, Cengiz; Çiner, Attila; Akif Sarıkaya, M.; Şahin, Sefa; Özcan, Orkan; Güneç Kıyak, Nafiye; Öztürk, Tuǧba

    2017-04-01

    From Late Miocene to present, Anatolia's rapid counterclockwise movement, which increases in velocity towards the Hellenic Arc, has formed the North Anatolian Fault (NAF), a dextral transform fault along the Anatolia-Eurasia plate boundary and the northern margin of the Central Anatolian Plateau (CAP). A zone of transpression referred to as the Central Pontides exists between the broad restraining bend of the NAF and the Black Sea Basin, uplifting what is interpreted as a detached flower structure. Dating of Quaternary landforms in the eastern flank of the Central Pontides has helped to understand its recent deformation. However, in the western flank of the Central Pontides there is an absence of Quaternary studies, relatively quiet modern seismicity, and difficulties locating or observing fault scarps. This led us to use optically stimulated luminescence dating (OSL-dating) of fluvial terrace sediments and the study of geomorphic features to gain insight into the influence of climate and tectonics on landscape evolution of this area. In this area, the Filyos River crosses the Karabük Fault (reverse fault) and deeply incises a gorge through the Karabük Range before flowing towards the Black Sea. In the gorge an abundance of indicators of tectonic deformation were mapped, such as hanging valleys, wind gaps, bedrock gorges, landslides, steep V-shaped channels, tilted basins, as well as fluvial strath terraces. In particular, strath terraces of at least 8 levels within just 1.5 km of horizontal distance were examined. We used OSL-dating to estimate five deposition ages of fluvial strath terrace sediments, leading to an estimation of incision and uplift rates over time. Using three samples per terrace with strath elevations of 246 ± 0.2 m, 105.49 ± 0.2 m, 43.6 ± 0.2 m, 15.3 ± 0.2 m and 3.6 ± 0.2 m above the Filyos River, we determined corresponding ages of 841 ± 76 ka, 681 ± 49 ka, 386 ± 18 ka, 88 ± 5.1 ka and 50.9 ± 2.8 ka. Incision rates over time (oldest terrace to youngest) suggest uplift of 0.29 ± 0.03 mm/y, 0.16 ± 0.01 mm/y, 0.10 ± 0.01 mm/y, 0.17 ± 0.01 mm/y and 0.07 ± 0.004 mm/y. Collectively, our ages infer decelerating fluvial incision and rock uplift rates in the Karabük Range of the Central Pontides. The highest rate that belongs to oldest terrace level (841 ± 76 ka) also implies long-term mean uplift, which is well correlated with long term ( 350 ka) mean uplift rate obtained from fluvial terraces in the eastern flank of the (Gökırmak Basin) Central Pontides. These results indicate Quaternary activity of the Karabük Fault despite the fact that very low modern seismicity and partition of strain in the north of the North Anatolian Fault. Keywords: Tectonics, Geomorphology, Fluvial Terrace, OSL Dating, Central Pontides, North Anatolian Fault, Filyos River, Turkey, Central Anatolian Plateau

  1. Numerical simulation of failure behavior of granular debris flows based on flume model tests.

    PubMed

    Zhou, Jian; Li, Ye-xun; Jia, Min-cai; Li, Cui-na

    2013-01-01

    In this study, the failure behaviors of debris flows were studied by flume model tests with artificial rainfall and numerical simulations (PFC(3D)). Model tests revealed that grain sizes distribution had profound effects on failure mode, and the failure in slope of medium sand started with cracks at crest and took the form of retrogressive toe sliding failure. With the increase of fine particles in soil, the failure mode of the slopes changed to fluidized flow. The discrete element method PFC(3D) can overcome the hypothesis of the traditional continuous medium mechanic and consider the simple characteristics of particle. Thus, a numerical simulations model considering liquid-solid coupled method has been developed to simulate the debris flow. Comparing the experimental results, the numerical simulation result indicated that the failure mode of the failure of medium sand slope was retrogressive toe sliding, and the failure of fine sand slope was fluidized sliding. The simulation result is consistent with the model test and theoretical analysis, and grain sizes distribution caused different failure behavior of granular debris flows. This research should be a guide to explore the theory of debris flow and to improve the prevention and reduction of debris flow.

  2. Failure Engineering Study and Accelerated Stress Test Results for the Mars Global Surveyor Spacecraft's Power Shunt Assemblies

    NASA Technical Reports Server (NTRS)

    Gibbel, Mark; Larson, Timothy

    2000-01-01

    An Engineering-of-Failure approach to designing and executing an accelerated product qualification test was performed to support a risk assessment of a "work-around" necessitated by an on-orbit failure of another piece of hardware on the Mars Global Surveyor spacecraft. The proposed work-around involved exceeding the previous qualification experience both in terms of extreme cold exposure level and in terms of demonstrated low cycle fatigue life for the power shunt assemblies. An analysis was performed to identify potential failure sites, modes and associated failure mechanisms consistent with the new use conditions. A test was then designed and executed which accelerated the failure mechanisms identified by analysis. Verification of the resulting failure mechanism concluded the effort.

  3. Ecological validity of the five digit test and the oral trails test.

    PubMed

    Paiva, Gabrielle Chequer de Castro; Fialho, Mariana Braga; Costa, Danielle de Souza; Paula, Jonas Jardim de

    2016-01-01

    Tests evaluating the attentional-executive system are widely used in clinical practice. However, proximity of an objective cognitive test with real-world situations (ecological validity) is not frequently investigated. The present study evaluate the association between measures of the Five Digit Test (FDT) and the Oral Trails Test (OTT) with self-reported cognitive failures in everyday life as measured by the Cognitive Failures Questionnaire (CFQ). Brazilian adults from 18-to-65 years old voluntarily performed the FDT and OTT tests and reported the frequency of cognitive failures in their everyday life through the CFQ. After controlling for the age effect, the measures of controlled attentional processes were associated with cognitive failures, yet the cognitive flexibility of both FDT and OTT accounted for by the majority of variance in most aspects of the CFQ factors. The FDT and the OTT measures were predictive of real-world problems such as cognitive failures in everyday activities/situations.

  4. 49 CFR Appendix A to Part 219 - Schedule of Civil Penalties

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...,000 Subpart F—Pre-Employment Tests 219.501Pre-employment tests: (a) Failure to perform pre-employment... required program $5,000 $7,500 219.11General conditions for chemical tests: (b)(1) Employee unlawfully....23Railroad policies: (a) Failure to provide written notice of FRA test 1,000 4,000 (b) Failure to provide...

  5. 49 CFR Appendix A to Part 219 - Schedule of Civil Penalties

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...,000 Subpart F—Pre-Employment Tests 219.501Pre-employment tests: (a) Failure to perform pre-employment... required program $5,000 $7,500 219.11General conditions for chemical tests: (b)(1) Employee unlawfully....23Railroad policies: (a) Failure to provide written notice of FRA test 1,000 4,000 (b) Failure to provide...

  6. 49 CFR Appendix A to Part 219 - Schedule of Civil Penalties

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...,000 Subpart F—Pre-Employment Tests 219.501Pre-employment tests: (a) Failure to perform pre-employment... required program $5,000 $7,500 219.11General conditions for chemical tests: (b)(1) Employee unlawfully....23Railroad policies: (a) Failure to provide written notice of FRA test 1,000 4,000 (b) Failure to provide...

  7. 49 CFR Appendix A to Part 219 - Schedule of Civil Penalties

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...,000 Subpart F—Pre-Employment Tests 219.501Pre-employment tests: (a) Failure to perform pre-employment... required program $5,000 $7,500 219.11General conditions for chemical tests: (b)(1) Employee unlawfully....23Railroad policies: (a) Failure to provide written notice of FRA test 1,000 4,000 (b) Failure to provide...

  8. 49 CFR Appendix A to Part 219 - Schedule of Civil Penalties

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...,000 Subpart F—Pre-Employment Tests 219.501Pre-employment tests: (a) Failure to perform pre-employment... required program $5,000 $7,500 219.11General conditions for chemical tests: (b)(1) Employee unlawfully....23Railroad policies: (a) Failure to provide written notice of FRA test 1,000 4,000 (b) Failure to provide...

  9. Heart failure - tests

    MedlinePlus

    CHF - tests; Congestive heart failure - tests; Cardiomyopathy - tests; HF - tests ... An echocardiogram (echo) is a test that uses sound waves to create a moving picture of the heart. The picture is much more detailed than a plain ...

  10. Catastrophic optical bulk degradation in high-power single- and multi-mode InGaAs-AlGaAs strained QW lasers: part II

    NASA Astrophysics Data System (ADS)

    Sin, Yongkun; Ayvazian, Talin; Brodie, Miles; Lingley, Zachary

    2018-03-01

    High-power single-mode (SM) and multi-mode (MM) InGaAs-AlGaAs strained quantum well (QW) lasers are critical components for both terrestrial and space satellite communications systems. Since these lasers predominantly fail by catastrophic and sudden degradation due to catastrophic optical damage (COD), it is especially crucial for space satellite applications to investigate reliability, failure modes, precursor signatures of failure, and degradation mechanisms of these lasers. Our group reported a new failure mode in MM and SM InGaAs-AlGaAs strained QW lasers in 2009 and 2016, respectively. Our group also reported in 2017 that bulk failure due to catastrophic optical bulk damage (COBD) is the dominant failure mode of both SM and MM lasers that were subject to long-term life-tests. For the present study, we continued our physics of failure investigation by performing long-term life-tests followed by failure mode analysis (FMA) using nondestructive and destructive micro-analytical techniques. We performed long-term accelerated life-tests on state-of-the-art SM and MM InGaAs- AlGaAs strained QW lasers under ACC mode. Our life-tests have accumulated over 25,000 test hours for SM lasers and over 35,000 test hours for MM lasers. We first employed electron beam induced current (EBIC) technique to identify failure modes of degraded SM lasers by observing dark line defects. All the SM failures that we studied showed catastrophic and sudden degradation and all of these failures were bulk failures. Since degradation mechanisms responsible for COBD are still not well understood, we also employed other techniques including focused ion beam (FIB) and high-resolution TEM to further study dark line defects and dislocations in post-aged lasers. Keywor

  11. AFRRI (Armed Forces Radiobiology Research Institute) Reports, January-March 1985

    DTIC Science & Technology

    1985-01-01

    monkey and human gastric functions Address osl i ,194 Arorlett: July~ (1, 1118. (6). .). and thle drug dosage was close to that ustid inAi~oattno...ionization chambers this requires the use of the two- * dosimeter method. One of the chambers is constructed of A-150 tissue- equivalent (TE) plastic, and...out excessively high flow rates. A photon energy-compensated Geiger- * Muller (GM) dosimeter is often used as the second dosimeter . However

  12. Technology Assessment and Roadmap for the Emergency Radiation Dose Assessment Program (ERDAP)

    DTIC Science & Technology

    2005-06-01

    l2O3:C OSL dosimeters . Overall design is based on similar systems described earlier by Justus et al. (1999) and Huston et al. (2001). Similar apparatus...Radioisotope Contamination 4. Pre-Positioned Physical Dosimeters C. Assessment of Emerging Dosimetry Technologies 1. Biological Measurements 2. Physico...architectures for radiation dose assessment tools. • Focus initial studies on defining the role of pre-positioned dosimeters , optimizing the size and

  13. Health and Safety Plan Data Item A009. Hamilton Army Airfield, Novato, California

    DTIC Science & Technology

    1990-11-01

    high-risk employees to the hazardous substance they encounter on-site. Dosimeters as presented in Subsection 5.2.1, must be worn at all times while...ow ode Go mnoM W mN.n ensum~e mm m gum 11.8 m a’= ~ ~ on" .. mme-o Nam ’emm Osl m... I ..oGneWa wow am. so 4vimsm e NMinu t 0m ~. .... .... I

  14. Failure Modes in Capacitors When Tested Under a Time-Varying Stress

    NASA Technical Reports Server (NTRS)

    Liu, David (Donhang)

    2011-01-01

    Steady step surge testing (SSST) is widely applied to screen out potential power-on failures in solid tantalum capacitors. The test simulates the power supply's on and off characteristics. Power-on failure has been the prevalent failure mechanism for solid tantalum capacitors for decoupling applications. On the other hand, the SSST can also be reviewed as an electrically destructive test under a time-varying stress. It consists of rapidly charging the capacitor with incremental voltage increases, through a low resistance in series, until the capacitor under test is electrically shorted. Highly accelerated life testing (HALT) is usually a time-efficient method for determining the failure mechanism in capacitors; however, a destructive test under a time-varying stress like SSST is even more effective. It normally takes days to complete a HALT test, but it only takes minutes for a time-varying stress test to produce failures. The advantage of incorporating specific time-varying stress into a statistical model is significant in providing an alternative life test method for quickly revealing the failure modes in capacitors. In this paper, a time-varying stress has been incorporated into the Weibull model to characterize the failure modes. The SSST circuit and transient conditions to correctly test the capacitors is discussed. Finally, the SSST was applied for testing polymer aluminum capacitors (PA capacitors), Ta capacitors, and multi-layer ceramic capacitors with both precious metal electrode (PME) and base-metal-electrodes (BME). It appears that testing results are directly associated to the dielectric layer breakdown in PA and Ta capacitors and are independent on the capacitor values, the way the capacitors being built, and the manufactures. The testing results also reveal that ceramic capacitors exhibit breakdown voltages more than 20 times the rated voltage, and the breakdown voltages are inverse proportional to the dielectric layer thickness. The possibility of ceramic capacitors in front-end decoupling applications to block the surge noise from a power supply is also discussed.

  15. Virtex-5 CN Package Daisy Chain Evaluation Test Report

    NASA Technical Reports Server (NTRS)

    Suh, Jong-ook

    2016-01-01

    The board-level temperature cycling reliability of Xilinx Virtex-5 (V5) CN package was investigated. V5s were temperature cycled under two conditions, 0 to +100 C (0/100) and -55 to +100 C (-55/100). During the 0/100 test, no part out of 8 parts failed up to 6586 cycles. During the -55/100 test, one part out of 8 parts failed at 1236 cycle, and there were no additional failures up to 1705 cycles. The failure mode of the part that failed at 1236 cycles indicated that most likely the failure was not a solder fatigue failure, and therefore no obvious solder fatigue failure was observed throughout the tests.

  16. Bone anchors or interference screws? A biomechanical evaluation for autograft ankle stabilization.

    PubMed

    Jeys, Lee; Korrosis, Sotiris; Stewart, Todd; Harris, Nicholas J

    2004-01-01

    Autograft stabilization uses free semitendinosus tendon grafts to anatomically reconstruct the anterior talofibular ligament. Study aims were to evaluate the biomechanical properties of Mitek GII anchors compared with the Arthrex Bio-Tenodesis Screw for free tendon reconstruction of the anterior talofibular ligament. There are no differences in load to failure and percentage specimen elongation at failure between the 2 methods. Controlled laboratory study using porcine models. Sixty porcine tendon constructs were failure tested. Re-creating the pull of the anterior talofibular ligament, loads were applied at 70 degrees to the bones. Thirty-six tendons were fixed to porcine tali and tested using a single pull to failure; 10 were secured with anchors and No. 2 Ethibond, 10 with anchors and FiberWire, 10 with screws and Fiberwire, and 6 with partially gripped screws. Cyclic preloading was conducted on 6 tendons fixed by anchors and on 6 tendons fixed by screws before failure testing. Two groups of 6 components fixed to the fibula were also tested. The talus single-pull anchor group produced a mean load of 114 N and elongation of 37% at failure. The talus single-pull screw group produced a mean load of 227 N and elongation of 22% at failure (P <.05). Cyclic preloading at 65% failure load before failure testing produced increases in load and decreases in elongation at failure. Partially gripped screws produced a load of 133 N and elongation of 30% at failure. The fibula model produced significant increases in load to failure for both. The human anterior talofibular ligament has loads of 139 N at failure with instability occurring at 20% elongation. Interference screw fixation produced significantly greater failure strength and less elongation at failure than bone anchors. The improved biomechanics of interference screws suggests that these may be more suited to in vivo reconstruction of the anterior talofibular ligament than are bone anchors.

  17. 14 CFR 61.49 - Retesting after failure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Retesting after failure. 61.49 Section 61.49 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED... failure. (a) An applicant for a knowledge or practical test who fails that test may reapply for the test...

  18. 14 CFR 61.49 - Retesting after failure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Retesting after failure. 61.49 Section 61.49 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED... failure. (a) An applicant for a knowledge or practical test who fails that test may reapply for the test...

  19. Environmental testing to prevent on-orbit TDRS failures

    NASA Technical Reports Server (NTRS)

    Cutler, Robert M.

    1994-01-01

    Can improved environmental testing prevent on-orbit component failures such as those experienced in the Tracking and Data Relay Satellite (TDRS) constellation? TDRS communications have been available to user spacecraft continuously for over 11 years, during which the five TDRS's placed in orbit have demonstrated their redundancies and robustness by surviving 26 component failures. Nevertheless, additional environmental testing prior to launch could prevent the occurrence of some types of failures, and could help to maintain communication services. Specific testing challenges involve traveling wave tube assemblies (TWTA's) whose lives may decrease with on-off cycling, and heaters that are subject to thermal cycles. The development of test conditions and procedures should account for known thermal variations. Testing may also have the potential to prevent failures in which components such as diplexers have had their lives dramatically shortened because of particle migration in a weightless environment. Reliability modeling could be used to select additional components that could benefit from special testing, but experience shows that this approach has serious limitations. Through knowledge of on-orbit experience, and with advances in testing, communication satellite programs might avoid the occurrence of some types of failures, and extend future spacecraft longevity beyond the current TDRS design life of ten years. However, determining which components to test, and how must testing to do, remain problematical.

  20. Deep flaws in weldments of aluminum and titanium

    NASA Technical Reports Server (NTRS)

    Masters, J. N.; Engstrom, W. L.; Bixler, W. D.

    1974-01-01

    Surface flawed specimens of 2219-T87 and 6Al-4V STA titanium weldments were tested to determine static failure modes, failure strength, and fatigue flaw growth characteristics. Thicknesses selected for this study were purposely set at values where, for most test conditions, abrupt instability of the flaw at fracture would not be expected. Static tests for the aluminum weldments were performed at room, LN2 and LH2 temperatures. Titanium static tests for tests were performed at room and LH2 temperatures. Results of the static tests were used to plot curves relating initial flaw size to leakage- or failure-stresses (i.e. "failure" locus curves). Cyclic tests, for both materials, were then performed at room temperature, using initial flaws only slightly below the previously established failure locus for typical proof stress levels. Cyclic testing was performed on pairs of specimens, one with and one without a simulated proof test cycle. Comparisons were made then to determine the value and effect of proof testing as affected by the various variables of proof and operating stress, flaw shape, material thickness, and alloy.

  1. Two-IMU FDI performance of the sequential probability ratio test during shuttle entry

    NASA Technical Reports Server (NTRS)

    Rich, T. M.

    1976-01-01

    Performance data for the sequential probability ratio test (SPRT) during shuttle entry are presented. Current modeling constants and failure thresholds are included for the full mission 3B from entry through landing trajectory. Minimum 100 percent detection/isolation failure levels and a discussion of the effects of failure direction are presented. Finally, a limited comparison of failures introduced at trajectory initiation shows that the SPRT algorithm performs slightly worse than the data tracking test.

  2. Tandem repeated application of organic solvents and sodium lauryl sulphate enhances cumulative skin irritation.

    PubMed

    Schliemann, Sibylle; Schmidt, Christina; Elsner, Peter

    2014-01-01

    The objective of our study was to investigate the tandem irritation potential of two organic solvents with concurrent exposure to the hydrophilic detergent irritant sodium lauryl sulphate (SLS). A tandem repeated irritation test was performed with two undiluted organic solvents, cumene (C) and octane (O), with either alternating application with SLS 0.5% or twice daily application of each irritant alone in 27 volunteers on the skin of the back. The cumulative irritation induced over 4 days was quantified using visual scoring and non-invasive bioengineering measurements (skin colour reflectance, skin hydration and transepidermal water loss). Repeated application of C/SLS and O/SLS induced more decline of stratum corneum hydration and higher degrees of clinical irritation and erythema compared to each irritant alone. Our results demonstrate a further example of additive harmful skin effects induced by particular skin irritants and indicate that exposure to organic solvents together with detergents may increase the risk of acquiring occupational contact dermatitis. © 2014 S. Karger AG, Basel.

  3. Personality Changes as a Function of Minimum Competency Test Success or Failure.

    ERIC Educational Resources Information Center

    Richman, Charles L.; And Others

    1987-01-01

    The psychological effects of success and failure on the North Carolina Minimum Competency Test (MCT) were examined. Subjects were high school students, who were pre- and post-tested using the Rosenberg Self Esteem Scale and the High School Personality Questionnaire. Self-esteem decreased following knowledge of MCT failure. (LMO)

  4. Pedo-sedimentary constituents as paleoenvironmental proxies in the Sudano-Sahelian belt during the Late Quaternary (southwestern Chad Basin)

    NASA Astrophysics Data System (ADS)

    Diaz, Nathalie; Dietrich, Fabienne; Sebag, David; King, Georgina E.; Valla, Pierre G.; Durand, Alain; Garcin, Yannick; de Saulieu, Geoffroy; Deschamps, Pierre; Herman, Frédéric; Verrecchia, Eric P.

    2018-07-01

    Climate and environmental changes since the Last Glacial Maximum in the tropical zone of West Africa are usually inferred from marine and continental records. In this study, the potential of carbonate pedo-sedimentary geosystems, i.e. Vertisol relics, to record paleoenvironmental changes in the southwestern part of Chad Basin are investigated. A multi-dating approach was applied on different pedogenic organo-mineral constituents. Optically stimulated luminescence (OSL) dating was performed on the soil K-rich feldspars and was combined with radiocarbon dating on both the inorganic (14Cinorg) and organic carbon (14Corg) soil fractions. Three main pedo-sedimentary processes were assessed over the last 20 ka BP: 1) the soil parent material deposition, from 18 ka to 12 ka BP (OSL), 2) the soil organic matter integration, from 11 cal ka to 8 cal ka BP (14Corg), and 3) the pedogenic carbonate nodule precipitation, from 7 cal ka to 5 cal ka BP (14Cinorg). These processes correlate well with the Chad Basin stratigraphy and West African records and are shown to be related to significant changes in the soil water balance responding to the evolution of continental hydrology during the Late Quaternary. The last phase affecting the Vertisol relics is the increase of erosion, which is hypothesized to be due to a decrease of the vegetation cover triggered by (i) the onset of drier conditions, possibly strengthened by (ii) anthropogenic pressure. Archaeological data from Far North Cameroon and northern Nigeria, as well as sedimentation times in Lake Tilla (northeastern Nigeria), were used to test these relationships. The increase of erosion is suggested to possibly occur between c. 3 cal ka and 1 cal ka BP. Finally, satellite images revealed similar geosystems all along the Sudano-Sahelian belt, and initial 14Cinorg ages of the samples collected in four sites gave similar ages to those reported in this study. Consequently, the carbonate pedo-sedimentary geosystems are valuable continental paleoenvironmental archives and soil water balance proxies of the semiarid tropics of West Africa.

  5. Coastal geology and recent origins for Sand Point, Lake Superior

    USGS Publications Warehouse

    Fisher, Timothy G.; Krantz, David E.; Castaneda, Mario R.; Loope, Walter L.; Jol, Harry M.; Goble, Ronald J.; Higley, Melinda C.; DeWald, Samantha; Hansen, Paul

    2014-01-01

    Sand Point is a small cuspate foreland located along the southeastern shore of Lake Superior within Pictured Rocks National Lakeshore near Munising, Michigan. Park managers’ concerns for the integrity of historic buildings at the northern periphery of the point during the rising lake levels in the mid-1980s greatly elevated the priority of research into the geomorphic history and age of Sand Point. To pursue this priority, we recovered sediment cores from four ponds on Sand Point, assessed subsurface stratigraphy onshore and offshore using geophysical techniques, and interpreted the chronology of events using radiocarbon and luminescence dating. Sand Point formed at the southwest edge of a subaqueous platform whose base is probably constructed of glacial diamicton and outwash. During the post-glacial Nipissing Transgression, the base was mantled with sand derived from erosion of adjacent sandstone cliffs. An aerial photograph time sequence, 1939–present, shows that the periphery of the platform has evolved considerably during historical time, infl uenced by transport of sediment into adjacent South Bay. Shallow seismic refl ections suggest slump blocks along the leading edge of the platform. Light detection and ranging (LiDAR) and shallow seismic refl ections to the northwest of the platform reveal large sand waves within a deep (12 m) channel produced by currents fl owing episodically to the northeast into Lake Superior. Ground-penetrating radar profi les show transport and deposition of sand across the upper surface of the platform. Basal radiocarbon dates from ponds between subaerial beach ridges range in age from 540 to 910 cal yr B.P., suggesting that Sand Point became emergent during the last ~1000 years, upon the separation of Lake Superior from Lakes Huron and Michigan. However, optically stimulated luminescence (OSL) ages from the beach ridges were two to three times as old as the radiocarbon ages, implying that emergence of Sand Point may have begun earlier, ~2000 years ago. The age discrepancy appears to be the result of incomplete bleaching of the quartz grains and an exceptionally low paleodose rate for the OSL samples. Given the available data, the younger ages from the radiocarbon analyses are preferred, but further work is necessary to test the two age models.

  6. Correlations of cave levels, stream terraces and planation surfaces along the River Mur—Timing of landscape evolution along the eastern margin of the Alps

    PubMed Central

    Wagner, Thomas; Fritz, Harald; Stüwe, Kurt; Nestroy, Othmar; Rodnight, Helena; Hellstrom, John; Benischke, Ralf

    2011-01-01

    The transition zone of the Eastern Alps to the Pannonian Basin provides one of the best sources of information on landscape evolution of the Eastern Alpine mountain range. The region was non-glaciated during the entire Pleistocene. Thus, direct influence of glacial carving as a landscape forming process can be excluded and relics of landforms are preserved that date back to at least the Late Neogene. In this study, we provide a correlation between various planation surfaces across the orogen-basin transition. In particular, we use stream terraces, planation surfaces and cave levels that cover a vertical spread of some 700 m. Our correlation is used to show that both sides of the transition zone uplifted together starting at least about 5 Ma ago. For our correlation we use recently published terrestrial cosmogenic nuclide (TCN) burial ages from cave sediments, new optically stimulated luminescence (OSL) ages of a stream terrace and U–Th ages from speleothems. Minimum age constraints of cave levels from burial ages of cave sediments covering the last ~ 4 Ma are used to place age constraints on surface features by parallelizing cave levels with planation surfaces. The OSL results for the top section of the type locality of the Helfbrunn terrace suggest an Early Würm development (80.5 ± 3.7 to 68.7 ± 4.0 ka). The terrace origin as a penultimate gravel deposit (in classical Alpine terminology Riss) is therefore questioned. U-series speleothem ages from caves nearby indicate formation during Marine Isotope Stages (MIS) 5c and 5a which are both interstadial warm periods. As OSL ages from the terrace also show a time of deposition during MIS 5a ending at the MIS 5/4 transition, this supports the idea of temperate climatic conditions at the time of deposition. In general, tectonic activity is interpreted to be the main driving force for the formation and evolution of these landforms, whilst climate change is suggested to be of minor importance. Obvious hiatuses in Miocene to Pleistocene sediments are related to ongoing erosion and re-excavation of an uplifting and rejuvenating landscape. PMID:22053124

  7. Catastrophic optical bulk degradation (COBD) in high-power single- and multi-mode InGaAs-AlGaAs strained quantum well lasers

    NASA Astrophysics Data System (ADS)

    Sin, Yongkun; Lingley, Zachary; Brodie, Miles; Presser, Nathan; Moss, Steven C.

    2017-02-01

    High-power single-mode (SM) and multi-mode (MM) InGaAs-AlGaAs strained quantum well (QW) lasers are critical components for both telecommunications and space satellite communications systems. However, little has been reported on failure modes and degradation mechanisms of high-power SM and MM InGaAs-AlGaAs strained QW lasers although it is crucial to understand failure modes and underlying degradation mechanisms in developing these lasers that meet lifetime requirements for space satellite systems, where extremely high reliability of these lasers is required. Our present study addresses the aforementioned issues by performing long-term life-tests followed by failure mode analysis (FMA) and physics of failure investigation. We performed long-term accelerated life-tests on state-of-the-art SM and MM InGaAs-AlGaAs strained QW lasers under ACC (automatic current control) mode. Our life-tests have accumulated over 25,000 test hours for SM lasers and over 35,000 test hours for MM lasers. FMA was performed on failed SM lasers using electron beam induced current (EBIC). This technique allowed us to identify failure types by observing dark line defects. All the SM failures we studied showed catastrophic and sudden degradation and all of these failures were bulk failures. Our group previously reported that bulk failure or COBD (catastrophic optical bulk damage) is the dominant failure mode of MM InGaAs-AlGaAs strained QW lasers. Since degradation mechanisms responsible for COBD are still not well understood, we also employed other techniques including focused ion beam (FIB) processing and high-resolution TEM to further study dark line defects and dislocations in post-aged lasers. Our long-term life-test results and FMA results are reported.

  8. Primary investigation the impacts of the external memory (DDR3) failures on the performance of Xilinx Zynq-7010 SoC based system (MicroZed) using laser irradiation

    NASA Astrophysics Data System (ADS)

    Liu, Shuhuan; Du, Xuecheng; Du, Xiaozhi; Zhang, Yao; Mubashiru, Lawal Olarewaju; Luo, Dongyang; yuan, Yuan; Deng, Tianxiang; Li, Zhuoqi; Zang, Hang; Li, Yonghong; He, Chaohui; Ma, Yingqi; Shangguan, Shipeng

    2017-09-01

    The impacts of the external dynamic memory (DDR3) failures on the performance of 28 nm Xilinx Zynq-7010 SoC based system (MicroZed) were investigated with two sets of 1064 nm laser platforms. The failure sensitive area distributionsons on the back surface of the test DDR3 were primarily localized with a CW laser irradiation platform. During the CW laser scanning on the back surface of the DDR3 of the test board system, various failure modes except SEU and SEL (MBU, SEFI, data storage address error, rebooting, etc) were found in the testing embedded modules (ALU, PL, Register, Cache and DMA, etc) of SoC. Moreover, the experimental results demonstrated that there were 16 failure sensitive blocks symmetrically distributed on the back surface of the DDR3 with every sensitive block area measured was about 1 mm × 0.5 mm. The influence factors on the failure modes of the embedded modules were primarily analyzed and the SEE characteristics of DDR3 induced by the picoseconds pulsed laser were tested. The failure modes of DDR3 found were SEU, SEFI, SEL, test board rebooting by itself, unknown data, etc. Furthermore, the time interval distributions of failure occurrence in DDR3 changes with the pulsed laser irradiation energy and the CPU operating frequency were measured and compared. Meanwhile, the failure characteristics of DDR3 induced by pulsed laser irradiation were primarily explored. The measured results and the testing techniques designed in this paper provide some reference information for evaluating the reliability of the test system or other similar electronic system in harsh environment.

  9. Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee C. Cadwallader

    2010-06-01

    This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a small tritium-breeding test blanket module design for the International Thermonuclear Experimental Reactor. The FMEA was quantified with “generic” component failure rate data, and the failure events are binned into postulated initiating event families and frequency categories for safety assessment. An appendix to this report contains repair time data to support an occupational radiation exposure assessment for test blanket module maintenance.

  10. Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee C. Cadwallader

    2007-08-01

    This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a small tritium-breeding test blanket module design for the International Thermonuclear Experimental Reactor. The FMEA was quantified with “generic” component failure rate data, and the failure events are binned into postulated initiating event families and frequency categories for safety assessment. An appendix to this report contains repair time data to support an occupational radiation exposure assessment for test blanket module maintenance.

  11. Centrifuge Modeling of Rainfall Induced Slope Failure

    NASA Astrophysics Data System (ADS)

    Ling, H.; Wu, M.

    2006-12-01

    Rainfall induces slope failure and debris flow which are considered as one of the major natural disasters. The scope of such failure is very large and it cannot be studied easily in the laboratory. Traditionally, small scale model tests are used to study such problem. Knowing that the behavior of soil is affected by the stress level, centrifuge modeling technique has been used to simulate more realistically full scale earth structures. In this study, two series of tests were conducted on slopes under the centrifugal field with and without the presence of rainfall. The soil used was a mixture of sand and 15 percent fines. The slopes of angle 60 degrees were prepared at optimum water content in order to achieve the maximum density. In the first series of tests, three different slope heights of 10 cm, 15 cm and 20 cm were used. The gravity was increased gradually until slope failure in order to obtain the prototype failure height. The slope model was cut after the test in order to obtain the configuration of failure surface. It was found that the slope geometry normalized by the height at failure provided unique results. Knowing the slope height or gravity at failure, the second series of tests with rainfall were conducted slightly below the critical height. That is, after attaining the desired gravity, the rainfall was induced in the centrifuge. Special nozzles were used and calibrated against different levels of gravity in order to obtain desired rainfall intensity. Five different rainfall intensities were used on the 15-cm slopes at 80g and 60g, which corresponded to 12 m and 9 m slope height, respectively. The duration until failure for different rainfall intensities was obtained. Similar to the first series of tests, the slope model was cut and investigated after the test. The results showed that the failure surface was not significantly affected by the rainfall. That is, the excess pore pressure induced by rainfall generated slope failure. The prediction curves of rainfall intensity versus duration were obtained from the test results. Such curves are extremely useful for disaster management. This study indicated feasibilities of using centrifuge modeling technique in simulating rainfall induced slope failure. The results obtained may also be used for validating numerical tools.

  12. Losses, gain, and lasing in organic and perovskite active materials (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Pourdavoud, Neda; Riedl, Thomas J.

    2016-09-01

    Organic solid state lasers (OSLs) based on semiconducting polymers or small molecules have seen some significant progress over the past decade. Highly efficient organic gain materials combined with high-Q resonator geometries (distributed feedback (DFB), VCSEL, etc.) have enabled OSLs, optically pumped by simple inorganic laser diodes or even LEDs. However, some fundamental goals remain to be reached, like continuous wave (cw) operation and injection lasing. I will address various loss mechanisms related to accumulated triplet excitons or long-lived polarons that in combination with the particular photo-physics of organic gain media state the dominant road-blocks on the way to reach these goals. I will discuss the recent progress in fundamental understanding of these loss processes, which now provides a solid basis for modelling, e.g. of laser dynamics. Avenues to mitigate these fundamental loss mechanisms, e.g. by alternative materials will be presented. In this regard, a class of gain materials based on organo-lead halide perovskites re-entered the scene as light emitters, recently. Enjoying a tremendous lot of attention as active material for solution processed solar cells with a 20+% efficiency, they have recently unveiled their exciting photo-physics for lasing applications. Optically pumped lasing in these materials has been achieved. I will discuss some of the unique properties that render this class of materials a promising candidate to overcome some of the limitations of "classical" organic gain media.

  13. Thermoluminescence characteristics of a chondrite (Holbrook) and an aubrite achondrite (Norton County) meteorites.

    PubMed

    Bossin, Lily; Kazakis, Nikolaos A; Kitis, George; Tsirliganis, Nestor C

    2017-09-01

    The present study constitutes the first part of a meteorite project, currently in progress, towards the full and thorough dosimetric study (TL and OSL) of two different meteorites of recent fall, Norton County and Holbrook. Both meteorites exhibit strong TL sensitivity, linear dose response and no saturation for doses up to 2kGy. However, the two meteorites exhibited a very dissimilar TL glow curve and behaviour regarding sensitization and fading. Notably, the Norton County aubrite achondrite was found to exhibit a strong fading of the high-temperature peak (~300°C), attributed to anomalous fading, whereas Holbrook did not seem to show signs of anomalous fading. Since quantitative conclusions regarding the thermal and irradiation history of meteorites, require knowledge of the detailed peak structure of the glow curve and deeper understanding of the trapping mechanism, the glow curves, after irradiation in the range 10-2000Gy, were deconvoluted using general order kinetics. The fitting parameters extracted point towards complex non-strictly first order mechanisms with a multitude of traps acting very differently. All the above, combined with future OSL measurements, currently in progress, are expected to shed light on the nature of the involved traps in both phenomena (energy depth, light-resistance etc), which would allow to extract more concrete conclusions about their history. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Cryostratigraphy, sedimentology, and the late Quaternary evolution of the Zackenberg River delta, northeast Greenland

    NASA Astrophysics Data System (ADS)

    Gilbert, Graham L.; Cable, Stefanie; Thiel, Christine; Christiansen, Hanne H.; Elberling, Bo

    2017-05-01

    The Zackenberg River delta is located in northeast Greenland (74°30' N, 20°30' E) at the outlet of the Zackenberg fjord valley. The fjord-valley fill consists of a series of terraced deltaic deposits (ca. 2 km2) formed during relative sea-level (RSL) fall. We investigated the deposits using sedimentological and cryostratigraphic techniques together with optically stimulated luminescence (OSL) dating. We identify four facies associations in sections (4 to 22 m in height) exposed along the modern Zackenberg River and coast. Facies associations relate to (I) overriding glaciers, (II) retreating glaciers and quiescent glaciomarine conditions, (III) delta progradation in a fjord valley, and (IV) fluvial activity and niveo-aeolian processes. Pore, layered, and suspended cryofacies are identified in two 20 m deep ice-bonded sediment cores. The cryofacies distribution, together with low overall ground-ice content, indicates that permafrost is predominately epigenetic in these deposits. Fourteen OSL ages constrain the deposition of the cored deposits to between approximately 13 and 11 ka, immediately following deglaciation. The timing of permafrost aggradation was closely related to delta progradation and began following the subaerial exposure of the delta plain (ca. 11 ka). Our results reveal information concerning the interplay between deglaciation, RSL change, sedimentation, permafrost aggradation, and the timing of these events. These findings have implications for the timing and mode of permafrost aggradation in other fjord valleys in northeast Greenland.

  15. Paleoseismology of the Southern Section of the Black Mountains and Southern Death Valley Fault Zones, Death Valley, United States

    USGS Publications Warehouse

    Sohn, Marsha S.; Knott, Jeffrey R.; Mahan, Shannon

    2014-01-01

    The Death Valley Fault System (DVFS) is part of the southern Walker Lane–eastern California shear zone. The normal Black Mountains Fault Zone (BMFZ) and the right-lateral Southern Death Valley Fault Zone (SDVFZ) are two components of the DVFS. Estimates of late Pleistocene-Holocene slip rates and recurrence intervals for these two fault zones are uncertain owing to poor relative age control. The BMFZ southernmost section (Section 1W) steps basinward and preserves multiple scarps in the Quaternary alluvial fans. We present optically stimulated luminescence (OSL) dates ranging from 27 to 4 ka of fluvial and eolian sand lenses interbedded with alluvial-fan deposits offset by the BMFZ. By cross-cutting relations, we infer that there were three separate ground-rupturing earthquakes on BMFZ Section 1W with vertical displacement between 5.5 m and 2.75 m. The slip-rate estimate is ∼0.2 to 1.8 mm/yr, with an earthquake recurrence interval of 4,500 to 2,000 years. Slip-per-event measurements indicate Mw 7.0 to 7.2 earthquakes. The 27–4-ka OSL-dated alluvial fans also overlie the putative Cinder Hill tephra layer. Cinder Hill is offset ∼213 m by SDVFZ, which yields a tentative slip rate of 1 to 8 mm/yr for the SDVFZ.

  16. Effects of recording time and residue on dose-response by LiMgPO4: Tb, B ceramic disc synthesized via improved sintering process

    NASA Astrophysics Data System (ADS)

    Kong, Xirui; Fu, Zhilong; Que, Huiying; Fan, Yanwei; Chen, Zhaoyang; He, Chengfa

    2018-05-01

    The LiMgPO4: Tb, B ceramic disc is successfully synthesized via improved sintering method which enables the disc sample to have two flat and smooth surfaces. It is worth mentioning that the OSL signal intensity of LiMgPO4: Tb, B disc attenuates much faster than that of commercial Al2O3: C. It costs only 1 s to reduce the intensity to 10%, but the Al2O3:C needs more than 40 s to finish it. Some essential OSL properties related to the dose detection method of this sample also have been systematically investigated. Although the dose-response cure would have better linearity with longer recording time, extended recording time (≥6 s) will not make any contribution to the linearity of the curve. If the bleaching time is more than 35 s, the residue created by previous detection (high dose of 10 Gy) would do almost no influence (with a positive deviation lower than 5.59%) on next lower-dose detection (0.1 Gy). The material would reach its service life when the total-ionizing dose runs up to 30 k Gy. Therefore, the LiMgPO4: Tb, B ceramic material is a potential candidate for real-time dose monitoring with optical fiber telemetering technology.

  17. Identification and dating of indigenous water storage reservoirs along the Rio San José at Laguna Pueblo, western New Mexico, USA

    USGS Publications Warehouse

    Huckleberry, Gary; Ferguson, T.J.; Rittenour, Tammy M.; Banet, Chris; Mahan, Shannon

    2016-01-01

    An investigation into indigenous water storage on the Rio San José in western New Mexico was conducted in support of efforts by the Pueblo of Laguna to adjudicate their water rights. Here we focus on stratigraphy and geochronology of two Native American-constructed reservoirs. One reservoir located near the community of Casa Blanca was formed by a ∼600 m (2000 feet) long stone masonry dam that impounded ∼1.6 × 106 m3 (∼1300 acre-feet) of stored water. Four optically stimulated luminescence (OSL) ages obtained on reservoir deposits indicate that the dam was constructed prior to AD 1825. The other reservoir is located adjacent to Old Laguna Pueblo and contains only a small remnant of its former earthen dam. The depth and distribution of reservoir deposits and a photogrammetric analyses of relict shorelines indicate a storage capacity of ∼6.5 × 106 m3 (∼5300 ac-ft). OSL ages from above and below the base of the reservoir indicate that the reservoir was constructed sometime after AD 1370 but before AD 1750. The results of our investigation are consistent with Laguna oral history and Spanish accounts demonstrating indigenous construction of significant water-storage reservoirs on the Rio San José prior to the late nineteenth century.

  18. Age and extent of a giant glacial-dammed lake at Yarlung Tsangpo gorge in the Tibetan Plateau

    NASA Astrophysics Data System (ADS)

    Liu, Weiming; Lai, Zhongping; Hu, Kaiheng; Ge, Yonggang; Cui, Peng; Zhang, Xiaogang; Liu, Feng

    2015-10-01

    Many glacier dams on major rivers at the southeastern edge of the Tibetan Plateau had been previously determined through remote sensing and glacier terminal position calculation. It was hypothesized that such damming substantially impeded river incision into the plateau interior. Investigation on the large glacial-dammed lake at the entrance of Tsangpo gorge is critical for understanding this hypothesis. So far, the issues, such as age, lake surface elevation, and stages of this dammed lake, are still in debate. Our field survey of lacustrine deposits and loess distribution along the middle Yarlung Tsangpo River and its tributary, Nyang River, suggested that the lake surface elevation was at about 3180 m asl. The 23 quartz optically stimulated luminescence (OSL) and 4 organic AMS 14C ages all fall into the Last Glacial period ( 41-13 ka). The OSL and 14C ages are in general agreement with each other where applicable. There might be only one long damming event because the ages of lacustrine deposits from 2970 to 3100 m asl are similar, and every lacustrine section is sustained for a long time. The estimated lake surface area was 1089 km2, and the volume was 170 km3, which differ from previous estimations which suggested two-stage (about early Holocene and 1.5 ka) lakes, and the largest lake surface elevation reached 3500 m.

  19. An improved approach for flight readiness certification: Methodology for failure risk assessment and application examples. Volume 2: Software documentation

    NASA Technical Reports Server (NTRS)

    Moore, N. R.; Ebbeler, D. H.; Newlin, L. E.; Sutharshana, S.; Creager, M.

    1992-01-01

    An improved methodology for quantitatively evaluating failure risk of spaceflight systems to assess flight readiness and identify risk control measures is presented. This methodology, called Probabilistic Failure Assessment (PFA), combines operating experience from tests and flights with engineering analysis to estimate failure risk. The PFA methodology is of particular value when information on which to base an assessment of failure risk, including test experience and knowledge of parameters used in engineering analyses of failure phenomena, is expensive or difficult to acquire. The PFA methodology is a prescribed statistical structure in which engineering analysis models that characterize failure phenomena are used conjointly with uncertainties about analysis parameters and/or modeling accuracy to estimate failure probability distributions for specific failure modes, These distributions can then be modified, by means of statistical procedures of the PFA methodology, to reflect any test or flight experience. Conventional engineering analysis models currently employed for design of failure prediction are used in this methodology. The PFA methodology is described and examples of its application are presented. Conventional approaches to failure risk evaluation for spaceflight systems are discussed, and the rationale for the approach taken in the PFA methodology is presented. The statistical methods, engineering models, and computer software used in fatigue failure mode applications are thoroughly documented.

  20. An improved approach for flight readiness certification: Methodology for failure risk assessment and application examples, volume 1

    NASA Technical Reports Server (NTRS)

    Moore, N. R.; Ebbeler, D. H.; Newlin, L. E.; Sutharshana, S.; Creager, M.

    1992-01-01

    An improved methodology for quantitatively evaluating failure risk of spaceflight systems to assess flight readiness and identify risk control measures is presented. This methodology, called Probabilistic Failure Assessment (PFA), combines operating experience from tests and flights with engineering analysis to estimate failure risk. The PFA methodology is of particular value when information on which to base an assessment of failure risk, including test experience and knowledge of parameters used in engineering analyses of failure phenomena, is expensive or difficult to acquire. The PFA methodology is a prescribed statistical structure in which engineering analysis models that characterize failure phenomena are used conjointly with uncertainties about analysis parameters and/or modeling accuracy to estimate failure probability distributions for specific failure modes. These distributions can then be modified, by means of statistical procedures of the PFA methodology, to reflect any test or flight experience. Conventional engineering analysis models currently employed for design of failure prediction are used in this methodology. The PFA methodology is described and examples of its application are presented. Conventional approaches to failure risk evaluation for spaceflight systems are discussed, and the rationale for the approach taken in the PFA methodology is presented. The statistical methods, engineering models, and computer software used in fatigue failure mode applications are thoroughly documented.

  1. Determining the influence of calcification on the failure properties of abdominal aortic aneurysm (AAA) tissue.

    PubMed

    O'Leary, Siobhan A; Mulvihill, John J; Barrett, Hilary E; Kavanagh, Eamon G; Walsh, Michael T; McGloughlin, Tim M; Doyle, Barry J

    2015-02-01

    Varying degrees of calcification are present in most abdominal aortic aneurysms (AAAs). However, their impact on AAA failure properties and AAA rupture risk is unclear. The aim of this work is evaluate and compare the failure properties of partially calcified and predominantly fibrous AAA tissue and investigate the potential reasons for failure. Uniaxial mechanical testing was performed on AAA samples harvested from 31 patients undergoing open surgical repair. Individual tensile samples were divided into two groups: fibrous (n=31) and partially calcified (n=38). The presence of calcification was confirmed by fourier transform infrared spectroscopy (FTIR). A total of 69 mechanical tests were performed and the failure stretch (λf), failure stress (σf) and failure tension (Tf) were recorded for each test. Following mechanical testing, the failure sites of a subset of both tissue types were examined using scanning electron microscopy (SEM)/energy dispersive X-ray spectroscopy (EDS) to investigate the potential reasons for failure. It has been shown that the failure properties of partially calcified tissue are significantly reduced compared to fibrous tissue and SEM and EDS results suggest that the junction between a calcification deposit and the fibrous matrix is highly susceptible to failure. This study implicates the presence of calcification as a key player in AAA rupture risk and provides further motivation for the development of non-invasive methods of measuring calcification. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Improvement program for polycarbonate capacitors. [hermetically sealed, and ac wound

    NASA Technical Reports Server (NTRS)

    Bailey, R. R.; Waterman, K. D.

    1973-01-01

    Hermetically sealed, wound, AC, polycarbonate capacitors incorporating design improvements recommended in a previous study were designed and built. A 5000 hour, 400 Hz ac life test was conducted using 384 of these capacitors to verify the adequacy of the design improvements. The improvements incorporated in the capacitors designed for this program eliminated the major cause of failure found in the preceding work, termination failure. A failure cause not present in the previous test became significant in this test with capacitors built from one lot of polycarbonate film. The samples from this lot accounted for 25 percent of the total test complement. Analyses of failed samples showed that the film had an excessive solvent content. This solvent problem was found in 37 of the total 46 failures which occurred in this test. The other nine were random failures resulting from causes such as seal leaks, foreign particles, and possibly wrinkles.

  3. A revised burial dose estimation procedure for optical dating of youngand modern-age sediments

    USGS Publications Warehouse

    Arnold, L.J.; Roberts, R.G.; Galbraith, R.F.; DeLong, S.B.

    2009-01-01

    The presence of genuinely zero-age or near-zero-age grains in modern-age and very young samples poses a problem for many existing burial dose estimation procedures used in optical (optically stimulated luminescence, OSL) dating. This difficulty currently necessitates consideration of relatively simplistic and statistically inferior age models. In this study, we investigate the potential for using modified versions of the statistical age models of Galbraith et??al. [Galbraith, R.F., Roberts, R.G., Laslett, G.M., Yoshida, H., Olley, J.M., 1999. Optical dating of single and multiple grains of quartz from Jinmium rock shelter, northern Australia: Part I, experimental design and statistical models. Archaeometry 41, 339-364.] to provide reliable equivalent dose (De) estimates for young and modern-age samples that display negative, zero or near-zero De estimates. For this purpose, we have revised the original versions of the central and minimum age models, which are based on log-transformed De values, so that they can be applied to un-logged De estimates and their associated absolute standard errors. The suitability of these 'un-logged' age models is tested using a series of known-age fluvial samples deposited within two arroyo systems from the American Southwest. The un-logged age models provide accurate burial doses and final OSL ages for roughly three-quarters of the total number of samples considered in this study. Sensitivity tests reveal that the un-logged versions of the central and minimum age models are capable of producing accurate burial dose estimates for modern-age and very young (<350??yr) fluvial samples that contain (i) more than 20% of well-bleached grains in their De distributions, or (ii) smaller sub-populations of well-bleached grains for which the De values are known with high precision. Our results indicate that the original (log-transformed) versions of the central and minimum age models are still preferable for most routine dating applications, since these age models are better suited to the statistical properties of typical single-grain and multi-grain single-aliquot De datasets. However, the unique error properties of modern-age samples, combined with the problems of calculating natural logarithms of negative or zero-Gy De values, mean that the un-logged versions of the central and minimum age models currently offer the most suitable means of deriving accurate burial dose estimates for very young and modern-age samples. ?? 2009 Elsevier Ltd. All rights reserved.

  4. Service Life Extension of the Propulsion System of Long-Term Manned Orbital Stations

    NASA Technical Reports Server (NTRS)

    Kamath, Ulhas; Kuznetsov, Sergei; Spencer, Victor

    2014-01-01

    One of the critical non-replaceable systems of a long-term manned orbital station is the propulsion system. Since the propulsion system operates beginning with the launch of station elements into orbit, its service life determines the service life of the station overall. Weighing almost a million pounds, the International Space Station (ISS) is about four times as large as the Russian space station Mir and about five times as large as the U.S. Skylab. Constructed over a span of more than a decade with the help of over 100 space flights, elements and modules of the ISS provide more research space than any spacecraft ever built. Originally envisaged for a service life of fifteen years, this Earth orbiting laboratory has been in orbit since 1998. Some elements that have been launched later in the assembly sequence were not yet built when the first elements were placed in orbit. Hence, some of the early modules that were launched at the inception of the program were already nearing the end of their design life when the ISS was finally ready and operational. To maximize the return on global investments on ISS, it is essential for the valuable research on ISS to continue as long as the station can be sustained safely in orbit. This paper describes the work performed to extend the service life of the ISS propulsion system. A system comprises of many components with varying failure rates. Reliability of a system is the probability that it will perform its intended function under encountered operating conditions, for a specified period of time. As we are interested in finding out how reliable a system would be in the future, reliability expressed as a function of time provides valuable insight. In a hypothetical bathtub shaped failure rate curve, the failure rate, defined as the number of failures per unit time that a currently healthy component will suffer in a given future time interval, decreases during infant-mortality period, stays nearly constant during the service life and increases at the end when the design service life ends and wear-out phase begins. However, the component failure rates do not remain constant over the entire cycle life. The failure rate depends on various factors such as design complexity, current age of the component, operating conditions, severity of environmental stress factors, etc. Development, qualification and acceptance test processes provide rigorous screening of components to weed out imperfections that might otherwise cause infant mortality failures. If sufficient samples are tested to failure, the failure time versus failure quantity can be analyzed statistically to develop a failure probability distribution function (PDF), a statistical model of the probability of failure versus time. Driven by cost and schedule constraints however, spacecraft components are generally not tested in large numbers. Uncertainties in failure rate and remaining life estimates increase when fewer units are tested. To account for this, spacecraft operators prefer to limit useful operations to a period shorter than the maximum demonstrated service life of the weakest component. Running each component to its failure to determine the maximum possible service life of a system can become overly expensive and impractical. Spacecraft operators therefore, specify the required service life and an acceptable factor of safety (FOS). The designers use these requirements to limit the life test duration. Midway through the design life, when benefits justify additional investments, supplementary life test may be performed to demonstrate the capability to safely extend the service life of the system. An innovative approach is required to evaluate the entire system, without having to go through an elaborate test program of propulsion system elements. Evaluating every component through a brute force test program would be a cost prohibitive and time consuming endeavor. ISS propulsion system components were designed and built decades ago. There are no representative ground test articles for some of the components. A 'test everything' approach would require manufacturing new test articles. The paper outlines some of the techniques used for selective testing, by way of cherry picking candidate components based on failure mode effects analysis, system level impacts, hazard analysis, etc. The type of testing required for extending the service life depends on the design and criticality of the component, failure modes and failure mechanisms, life cycle margin provided by the original certification, operational and environmental stresses encountered, etc. When specific failure mechanism being considered and the underlying relationship of that mode to the stresses provided in the test can be correlated by supporting analysis, time and effort required for conducting life extension testing can be significantly reduced. Exposure to corrosive propellants over long periods of time, for instance, lead to specific failure mechanisms in several components used in the propulsion system. Using Arrhenius model, which is tied to chemically dependent failure mechanisms such as corrosion or chemical reactions, it is possible to subject carefully selected test articles to accelerated life test. Arrhenius model reflects the proportional relationship between time to failure of a component and the exponential of the inverse of absolute temperature acting on the component. The acceleration factor is used to perform tests at higher stresses that allow direct correlation between the times to failure at a high test temperature to the temperatures to be expected in actual use. As long as the temperatures are such that new failure mechanisms are not introduced, this becomes a very useful method for testing to failure a relatively small sample of items for a much shorter amount of time. In this article, based on the example of the propulsion system of the first ISS module Zarya, theoretical approaches and practical activities of extending the service life of the propulsion system are reviewed with the goal of determining the maximum duration of its safe operation.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Chao; Xu, Jun; Cao, Lei

    The electrodes of lithium-ion batteries (LIB) are known to be brittle and to fail earlier than the separators during an external crush event. Thus, the understanding of mechanical failure mechanism for LIB electrodes (anode and cathode) is critical for the safety design of LIB cells. In this paper, we present experimental and numerical studies on the constitutive behavior and progression of failure in LIB electrodes. Mechanical tests were designed and conducted to evaluate the constitutive properties of porous electrodes. Constitutive models were developed to describe the stress-strain response of electrodes under uniaxial tensile and compressive loads. The failure criterion andmore » a damage model were introduced to model their unique tensile and compressive failure behavior. The failure mechanism of LIB electrodes was studied using the blunt rod test on dry electrodes, and numerical models were built to simulate progressive failure. The different failure processes were examined and analyzed in detail numerically, and correlated with experimentally observed failure phenomena. Finally, the test results and models improve our understanding of failure behavior in LIB electrodes, and provide constructive insights on future development of physics-based safety design tools for battery structures under mechanical abuse.« less

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lall, Pradeep; Wei, Junchao; Sakalaukus, Peter

    A new method has been developed for assessment of the onset of degradation in solid state luminaires to classify failure mechanisms by using metrics beyond lumen degradation that are currently used for identification of failure. Luminous Flux output, Correlated Color Temperature Data on Philips LED Lamps has been gathered under 85°C/85%RH till lamp failure. Failure modes of the test population of the lamps have been studied to understand the failure mechanisms in 85°C/85%RH accelerated test. Results indicate that the dominant failure mechanism is the discoloration of the LED encapsulant inside the lamps which is the likely cause for the luminousmore » flux degradation and the color shift. The acquired data has been used in conjunction with Bayesian Probabilistic Models to identify luminaires with onset of degradation much prior to failure through identification of decision boundaries between lamps with accrued damage and lamps beyond the failure threshold in the feature space. In addition luminaires with different failure modes have been classified separately from healthy pristine luminaires. The α-λ plots have been used to evaluate the robustness of the proposed methodology. Results show that the predicted degradation for the lamps tracks the true degradation observed during 85°C/85%RH during accelerated life test fairly closely within the ±20% confidence bounds. Correlation of model prediction with experimental results indicates that the presented methodology allows the early identification of the onset of failure much prior to development of complete failure distributions and can be used for assessing the damage state of SSLs in fairly large deployments. It is expected that, the new prediction technique will allow the development of failure distributions without testing till L70 life for the manifestation of failure.« less

  7. Factors associated with failure to return for HIV test results in a free and anonymous screening centre.

    PubMed

    Laanani, Moussa; Dozol, Adrien; Meyer, Laurence; David, Stéphane; Camara, Sékou; Segouin, Christophe; Troude, Pénélope

    2015-07-01

    Free and anonymous screening centres (CDAG: Centres de Depistage Anononyme et Gratuit) are public facilities set up for HIV infection diagnosis in France. Some people visiting CDAG fail to return for test results and are not informed of their serology. This study aimed to assess factors associated with failure to return for HIV test results. Patients visiting the Fernand-Widal CDAG (Paris) for an HIV test in January-February 2011 were eligible to take part in the study. Data were collected with an anonymous self-administered questionnaire. Factors associated with failure to return were assessed using logistic regression models. Of the 710 participants (participation rate 88%), 46 patients failed to return. Not specifying birthplace and not living in the region of Paris were associated with failure to return. Those who perceived no risk of HIV infection and those who felt they were more at risk than other people were both statistically associated with failure to return. Self-perceived risk seemed to be of chief concern for failure to return for HIV test results and should be considered during pre-test counselling. © The Author(s) 2014.

  8. Failure Modes in Capacitors When Tested Under a Time-Varying Stress

    NASA Technical Reports Server (NTRS)

    Liu, David (Donhang)

    2011-01-01

    Power-on failure has been the prevalent failure mechanism for solid tantalum capacitors in decoupling applications. A surge step stress test (SSST) has been previously applied to identify the critical stress level of a capacitor batch to give some predictability to the power-on failure mechanism [1]. But SSST can also be viewed as an electrically destructive test under a time-varying stress (voltage). It consists of rapidly charging the capacitor with incremental voltage increases, through a low resistance in series, until the capacitor under test is electrically shorted. When the reliability of capacitors is evaluated, a highly accelerated life test (HALT) is usually adopted since it is a time-efficient method of determining the failure mechanism; however, a destructive test under a time-varying stress such as SSST is even more time efficient. It usually takes days or weeks to complete a HALT test, but it only takes minutes for a time-varying stress test to produce failures. The advantage of incorporating a specific time-varying stress profile into a statistical model is significant in providing an alternative life test method for quickly revealing the failure mechanism in capacitors. In this paper, a time-varying stress that mimics a typical SSST has been incorporated into the Weibull model to characterize the failure mechanism in different types of capacitors. The SSST circuit and transient conditions for correctly surge testing capacitors are discussed. Finally, the SSST was applied for testing Ta capacitors, polymer aluminum capacitors (PA capacitors), and multi-layer ceramic (MLC) capacitors with both precious metal electrodes (PME) and base metal electrodes (BME). The test results are found to be directly associated with the dielectric layer breakdown in Ta and PA capacitors and are independent of the capacitor values, the way the capacitors were built, and the capacitors manufacturers. The test results also show that MLC capacitors exhibit surge breakdown voltages much higher than the rated voltage and that the breakdown field is inversely proportional to the dielectric layer thickness. The SSST data can also be used to comparatively evaluate the voltage robustness of capacitors for decoupling applications.

  9. The effect of different bleaching wavelengths on the sensitivity of Al{sub 2}O{sub 3}:C optically stimulated luminescence detectors (OSLDs) exposed to 6 MV photon beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Omotayo, Azeez A.; Cygler, Joanna E.; Sawakuchi, Gabriel O.

    2012-09-15

    Purpose: To determine the effect of different bleaching wavelengths on the response of Al{sub 2}O{sub 3}:C optically stimulated luminescence detectors (OSLDs) exposed to accumulated doses of 6 MV photon beams. Methods: In this study the authors used nanoDot OSLDs readout with a MicroStar reader. The authors first characterized the dose-response, fading, and OSL signal loss of OSLDs exposed to doses from 0.5 to 10 Gy. To determine the effect of different bleaching wavelengths on the OSLDs' response, the authors optically treated the OSLDs with 26 W fluorescent lamps in two modes: (i) directly under the lamps for 10, 120, andmore » 600 min and (ii) with a long-pass filter for 55, 600, and 2000 min. Changes in the OSLDs' sensitivity were determined for an irradiation-readout-bleaching-readout cycle after irradiations with 1 and 10 Gy dose fractions. Results: The OSLDs presented supralinearity for doses of 2 Gy and above. The signal loss rates for sequential readouts were (0.287 {+-} 0.007)% per readout in the reader's strong-stimulation mode, and (0.019 {+-} 0.002)% and (0.035 {+-} 0.007)% per readout for doses of 0.2 and 10 Gy, respectively, in the reader's weak-stimulation mode. Fading half-life values ranged from (0.98 {+-} 0.14) min to (1.77 {+-} 0.24) min and fading showed dose dependence for the first 10-min interval. For 10 and 55 min bleaching using modes (i) and (ii), the OSL signal increased 14% for an accumulated dose of 7 Gy (1 Gy fractions). For OSLDs exposed to 10 Gy fractions, the OSL signal increased 30% and 25% for bleaching modes (i) and (ii) and accumulated dose of 70 Gy, respectively. For 120 and 600 min bleaching using modes (i) and (ii), the OSL signal increased 2.7% and 1.5% for an accumulated dose of 7 Gy (1 Gy fractions), respectively. For 10 Gy fractions, the signal increased 14% for bleaching mode (i) (120 min bleaching) and decreased 1.3% for bleaching mode (ii) (600 min bleaching) for an accumulated dose of 70 Gy. For 600 and 2000 min bleaching using modes (i) and (ii), the signal increased 2.3% and 1.8% for an accumulated dose of 7 Gy (1 Gy fractions), respectively. For 10 Gy fractions, the signal increased 10% for mode (i) (600 min bleaching) and decreased 2.5% for mode (ii) (2000 min bleaching) for an accumulated dose of 70 Gy. Conclusions: The dose-response of nanoDot OSLDs read using the MicroStar reader presented supralinearity for doses of 2 Gy and above. The signal loss as a function of sequential readouts depended on dose. Fading also depended on dose for the first 10-min interval. For dose fractions of 1 and 10 Gy, OSLDs may be reused within 3% and 5% accuracies up to the maximum accumulated dose of 7 and 70 Gy investigated in this study, respectively. These accuracies were obtained after the OSLDs were bleached with a light source with wavelengths above about 495 nm. The authors also concluded that changes in sensitivity of OSLDs depended on bleaching time, accumulated dose, and wavelength spectrum of the bleaching source.« less

  10. Constitutive behavior and progressive mechanical failure of electrodes in lithium-ion batteries

    NASA Astrophysics Data System (ADS)

    Zhang, Chao; Xu, Jun; Cao, Lei; Wu, Zenan; Santhanagopalan, Shriram

    2017-07-01

    The electrodes of lithium-ion batteries (LIB) are known to be brittle and to fail earlier than the separators during an external crush event. Thus, the understanding of mechanical failure mechanism for LIB electrodes (anode and cathode) is critical for the safety design of LIB cells. In this paper, we present experimental and numerical studies on the constitutive behavior and progression of failure in LIB electrodes. Mechanical tests were designed and conducted to evaluate the constitutive properties of porous electrodes. Constitutive models were developed to describe the stress-strain response of electrodes under uniaxial tensile and compressive loads. The failure criterion and a damage model were introduced to model their unique tensile and compressive failure behavior. The failure mechanism of LIB electrodes was studied using the blunt rod test on dry electrodes, and numerical models were built to simulate progressive failure. The different failure processes were examined and analyzed in detail numerically, and correlated with experimentally observed failure phenomena. The test results and models improve our understanding of failure behavior in LIB electrodes, and provide constructive insights on future development of physics-based safety design tools for battery structures under mechanical abuse.

  11. Constitutive behavior and progressive mechanical failure of electrodes in lithium-ion batteries

    DOE PAGES

    Zhang, Chao; Xu, Jun; Cao, Lei; ...

    2017-05-05

    The electrodes of lithium-ion batteries (LIB) are known to be brittle and to fail earlier than the separators during an external crush event. Thus, the understanding of mechanical failure mechanism for LIB electrodes (anode and cathode) is critical for the safety design of LIB cells. In this paper, we present experimental and numerical studies on the constitutive behavior and progression of failure in LIB electrodes. Mechanical tests were designed and conducted to evaluate the constitutive properties of porous electrodes. Constitutive models were developed to describe the stress-strain response of electrodes under uniaxial tensile and compressive loads. The failure criterion andmore » a damage model were introduced to model their unique tensile and compressive failure behavior. The failure mechanism of LIB electrodes was studied using the blunt rod test on dry electrodes, and numerical models were built to simulate progressive failure. The different failure processes were examined and analyzed in detail numerically, and correlated with experimentally observed failure phenomena. Finally, the test results and models improve our understanding of failure behavior in LIB electrodes, and provide constructive insights on future development of physics-based safety design tools for battery structures under mechanical abuse.« less

  12. An Experimental Study of Launch Vehicle Propellant Tank Fragmentation

    NASA Technical Reports Server (NTRS)

    Richardson, Erin; Jackson, Austin; Hays, Michael; Bangham, Mike; Blackwood, James; Skinner, Troy; Richman, Ben

    2014-01-01

    In order to better understand launch vehicle abort environments, Bangham Engineering Inc. (BEi) built a test assembly that fails sample materials (steel and aluminum plates of various alloys and thicknesses) under quasi-realistic vehicle failure conditions. Samples are exposed to pressures similar to those expected in vehicle failure scenarios and filmed at high speed to increase understanding of complex fracture mechanics. After failure, the fragments of each test sample are collected, catalogued and reconstructed for further study. Post-test analysis shows that aluminum samples consistently produce fewer fragments than steel samples of similar thickness and at similar failure pressures. Video analysis shows that there are several failure 'patterns' that can be observed for all test samples based on configuration. Fragment velocities are also measured from high speed video data. Sample thickness and material are analyzed for trends in failure pressure. Testing is also done with cryogenic and noncryogenic liquid loading on the samples. It is determined that liquid loading and cryogenic temperatures can decrease material fragmentation for sub-flight thicknesses. A method is developed for capture and collection of fragments that is greater than 97 percent effective in recovering sample mass, addressing the generation of tiny fragments. Currently, samples tested do not match actual launch vehicle propellant tank material thicknesses because of size constraints on test assembly, but test findings are used to inform the design and build of another, larger test assembly with the purpose of testing actual vehicle flight materials that include structural components such as iso-grid and friction stir welds.

  13. Hypervelocity impact testing of the Space Station utility distribution system carrier

    NASA Technical Reports Server (NTRS)

    Lazaroff, Scott

    1993-01-01

    A two-phase, joint JSC and McDonnell Douglas Aerospace-Huntington Beach hypervelocity impact (HVI) test program was initiated to develop an improved understanding of how meteoroid and orbital debris (M/OD) impacts affect the Space Station Freedom (SSF) avionic and fluid lines routed in the Utility Distribution System (UDS) carrier. This report documents the first phase of the test program which covers nonpowered avionic line segment and pressurized fluid line segment HVI testing. From these tests, a better estimation of avionic line failures is approximately 15 failures per year and could very well drop to around 1 or 2 avionic line failures per year (depending upon the results of the second phase testing of the powered avionic line at White Sands). For the fluid lines, the initial McDonnell Douglas analysis calculated 1 to 2 line failures over a 30 year period. The data obtained from these tests indicate the number of predicted fluid line failures increased slightly to as many as 3 in the first 10 years and up to 15 for the entire 30 year life of SSF.

  14. An improved approach for flight readiness certification: Probabilistic models for flaw propagation and turbine blade failure. Volume 1: Methodology and applications

    NASA Technical Reports Server (NTRS)

    Moore, N. R.; Ebbeler, D. H.; Newlin, L. E.; Sutharshana, S.; Creager, M.

    1992-01-01

    An improved methodology for quantitatively evaluating failure risk of spaceflight systems to assess flight readiness and identify risk control measures is presented. This methodology, called Probabilistic Failure Assessment (PFA), combines operating experience from tests and flights with analytical modeling of failure phenomena to estimate failure risk. The PFA methodology is of particular value when information on which to base an assessment of failure risk, including test experience and knowledge of parameters used in analytical modeling, is expensive or difficult to acquire. The PFA methodology is a prescribed statistical structure in which analytical models that characterize failure phenomena are used conjointly with uncertainties about analysis parameters and/or modeling accuracy to estimate failure probability distributions for specific failure modes. These distributions can then be modified, by means of statistical procedures of the PFA methodology, to reflect any test or flight experience. State-of-the-art analytical models currently employed for designs failure prediction, or performance analysis are used in this methodology. The rationale for the statistical approach taken in the PFA methodology is discussed, the PFA methodology is described, and examples of its application to structural failure modes are presented. The engineering models and computer software used in fatigue crack growth and fatigue crack initiation applications are thoroughly documented.

  15. An improved approach for flight readiness certification: Probabilistic models for flaw propagation and turbine blade failure. Volume 2: Software documentation

    NASA Technical Reports Server (NTRS)

    Moore, N. R.; Ebbeler, D. H.; Newlin, L. E.; Sutharshana, S.; Creager, M.

    1992-01-01

    An improved methodology for quantitatively evaluating failure risk of spaceflights systems to assess flight readiness and identify risk control measures is presented. This methodology, called Probabilistic Failure Assessment (PFA), combines operating experience from tests and flights with analytical modeling of failure phenomena to estimate failure risk. The PFA methodology is of particular value when information on which to base an assessment of failure risk, including test experience and knowledge of parameters used in analytical modeling, is expensive or difficult to acquire. The PFA methodology is a prescribed statistical structure in which analytical models that characterize failure phenomena are used conjointly with uncertainties about analysis parameters and/or modeling accuracy to estimate failure probability distributions for specific failure modes. These distributions can then be modified, by means of statistical procedures of the PFA methodology, to reflect any test or flight experience. State-of-the-art analytical models currently employed for design, failure prediction, or performance analysis are used in this methodology. The rationale for the statistical approach taken in the PFA methodology is discussed, the PFA methodology is described, and examples of its application to structural failure modes are presented. The engineering models and computer software used in fatigue crack growth and fatigue crack initiation applications are thoroughly documented.

  16. Failure and fatigue characteristics of adhesive athletic tape.

    PubMed

    Bragg, Richard W; Macmahon, John M; Overom, Erin K; Yerby, Scott A; Matheson, Gordon O; Carter, Dennis R; Andriacchi, Thomas P

    2002-03-01

    Athletic tape has been commonly reported to lose much of its structural support after 20 min of exercise. Although many studies have addressed the functional performance characteristics of athletic tape, its mechanical properties are poorly understood. This study examines the failure and fatigue properties of several commonly used athletic tapes. A Web-based survey of professional sports trainers was used to select the following three tapes for the study: Zonas (Johnson & Johnson), Leukotape (Beiersdorf), and Jaylastic (Jaybird & Mais). Using a hydraulic material testing system (MTS), eight samples of each tape were compared in three different mechanical tests: load-to-failure, fatigue testing under load control, and fatigue testing under displacement control. Differences in tape microstructure were used to interpret the results of the mechanical tests. Significant differences (P < 0.001) in failure load, elongation at failure, and stiffness were found from failure tests. Significant differences were also found (P < 0.001) in fatigue behavior under both modes of control. As a representative example, in one normalized displacement control fatigue test after 20 min of cycling, 21% (Zonas), 29% (Leukotape), and 57% (Jaylastic) of the mechanical support was lost. After cycling, all tapes loaded to failure showed increased stiffness (P < 0.001), indicating significant energy absorption during cycling. Observed differences in the tapes' microstructure were qualitatively consistent with the measured differences in their mechanical properties. In understanding the shortcomings of currently available tapes, the results of these tests can now be used as benchmarks with which to compare and develop future tape designs. Ultimately, these improved tapes should reduce ankle injuries among athletes.

  17. [Action-oriented versus state-oriented reactions to experimenter-induced failures].

    PubMed

    Brunstein, J C

    1989-01-01

    The present study assessed different effects of action-oriented versus state-oriented styles of coping with failure on achievement-related performance and cognition. In a learned helplessness experiment, students were exposed to an academic failure situation and were then tested on a series of problem-solving tasks, either immediately after the pretreatment or after a delay of 24 hours. Performance and cognitive concomitants were measured during both experimental periods. Results demonstrated that action orientation was associated with self-immunizing cognitions during helplessness training. Action-oriented participants improved their performance level even after repeated failure feedbacks. Moreover, action-oriented students assigned to the delayed test condition responded with increased striving for success and showed performance increments, even in comparison with control subjects. In contrast, state-oriented participants developed symptoms of helplessness and showed impaired performance during failure inductions. In later tests on problem-solving tasks, state-oriented groups responded with increased fear of failure. Independent of immediate or delayed test conditions, they soon lapsed into new performance decrements.

  18. On-clip high frequency reliability and failure test structures

    DOEpatents

    Snyder, Eric S.; Campbell, David V.

    1997-01-01

    Self-stressing test structures for realistic high frequency reliability characterizations. An on-chip high frequency oscillator, controlled by DC signals from off-chip, provides a range of high frequency pulses to test structures. The test structures provide information with regard to a variety of reliability failure mechanisms, including hot-carriers, electromigration, and oxide breakdown. The system is normally integrated at the wafer level to predict the failure mechanisms of the production integrated circuits on the same wafer.

  19. Verification of the Multi-Axial, Temperature and Time Dependent (MATT) Failure Criterion

    NASA Technical Reports Server (NTRS)

    Richardson, David E.; Macon, David J.

    2005-01-01

    An extensive test and analytical effort has been completed by the Space Shuttle's Reusable Solid Rocket Motor (KSKM) nozzle program to characterize the failure behavior of two epoxy adhesives (TIGA 321 and EA946). As part of this effort, a general failure model, the "Multi-Axial, Temperature, and Time Dependent" or MATT failure criterion was developed. In the initial development of this failure criterion, tests were conducted to provide validation of the theory under a wide range of test conditions. The purpose of this paper is to present additional verification of the MATT failure criterion, under new loading conditions for the adhesives TIGA 321 and EA946. In many cases, the loading conditions involve an extrapolation from the conditions under which the material models were originally developed. Testing was conducted using three loading conditions: multi-axial tension, torsional shear, and non-uniform tension in a bondline condition. Tests were conducted at constant and cyclic loading rates ranging over four orders of magnitude. Tests were conducted under environmental conditions of primary interest to the RSRM program. The temperature range was not extreme, but the loading ranges were extreme (varying by four orders of magnitude). It should be noted that the testing was conducted at temperatures below the glass transition temperature of the TIGA 321 adhesive. However for the EA946, the testing was conducted at temperatures that bracketed the glass transition temperature.

  20. Experimental investigation on the failure of T-joints at elevated temperature under unaxial loading

    NASA Astrophysics Data System (ADS)

    Bahri, N. F.; Afendi, M.; Razlan, Z. M.; Nor, A.; Baharuddin, S. A.

    2017-09-01

    In this study, the mechanical properties and maximum failure load of a bulk and T-joints subjected to tensile loading were investigated experimentally. A bulk and the T-joint specimens were fabricated and tested in order to investigate the effects of temperature conditions on the failure of the joints. The adherent and adhesive used for T-joint are 304 L stainless steel and Hysol E 214 HP with the adhesive thickness of 1.0 mm. The tensile test of the bulk specimen and adhesively T-joint were conducted by using a universal testing machine (UTM) at room temperature (RT), 55 °C, 75 °C, 100 °C and 120 °C, respectively. It was found that as the temperature increases, the failure force strength decreases for bulk and T-joint specimen. Data obtained from the tests at 120 °C showed the failure force of the bulk adhesive decreased by approximately 44 % compared to the specimen tested at RT. Next, the bulk of Hysol failure force result was compared with Araldite at RT and 100 °C. Araldite data was taken from the previous study [1]. It has also been found that the bulk for Hysol has higher failure force compared to Araldite at RT and 100 °C.

  1. Computerised curve deconvolution of TL/OSL curves using a popular spreadsheet program.

    PubMed

    Afouxenidis, D; Polymeris, G S; Tsirliganis, N C; Kitis, G

    2012-05-01

    This paper exploits the possibility of using commercial software for thermoluminescence and optically stimulated luminescence curve deconvolution analysis. The widely used software package Microsoft Excel, with the Solver utility has been used to perform deconvolution analysis to both experimental and reference glow curves resulted from the GLOw Curve ANalysis INtercomparison project. The simple interface of this programme combined with the powerful Solver utility, allows the analysis of complex stimulated luminescence curves into their components and the evaluation of the associated luminescence parameters.

  2. Job Language Performance Requirements for MOS 44B. Metal Worker. Reference Soldier’s Manual Dated 17 April 1979.

    DTIC Science & Technology

    1979-04-17

    i I tie frlr. o, -J*:, i io s )r *i r -is 1 :1 iv 71 1, q. Q’ " n -’ d to - ’ln t i: s ’I osl o SA A~S: 11,0% unid-rs! n d i of ?rint, d c ,,.I tt...readings off dosimeter Coordinate scales Callsigns-suffices Three-letter codes Exmples Calculations Markings Radio comunications Range cards Notes Messages V

  3. Feasibility of Epidemiologic Research on Nonauditory Health Effects of Residential Aircraft Noise Exposure. Volume 3. Summary of Literature on Cardiovascular Effects on Noise Exposure

    DTIC Science & Technology

    1989-12-01

    analyser epinephrine, dopamine, Cigala, F.; shop and sorting, and General Rodo cortisol measured Ricco, M.; matched for age, exposed personal dosimeters ...old sured by calibrated person- BP with semi-automatic de Vries, F. F.; duction depart- 31% 25-34 yrs.; al dosimeters with a short Waterpik...with without noise strain, history of hyper- tension excluded. 84 Table 3-23: continued. Suammuy of Epid oSl c Sades - contnud Bias and Potential

  4. AFRRI (Armed Forces Radiobiology Research Institute) Annual Research Report 1 October 1981-30 September 1982.

    DTIC Science & Technology

    1982-09-30

    inseiw @, I, M, ,5 oSL -T- UNCLASNYR SECUIRI1’I CLAWFICAIss 00 T0111 0"t 59Mea-.40 - --.---------------------- A CONTENTS Introduction 3 Behavioral...urinary histamine as a biological dosimeter . This study reports the techniques we have developed to determine the levels of authentic histamine in rat urine...Studies of biological indicators in the assessment of radiation damage, with particular interest to developing a biological dosimeter using red blood cell

  5. Relocation of the 146th Tactical Airlift Wing of the California Air National Guard. Appendices

    DTIC Science & Technology

    1984-12-01

    or Afu~rmydsr osl ama~ asserted that the Secretary is required to tose they assist would convert *’ .*resge’lo a developer for construction report...1%Woreinento were recorded with a claibrated noise dosimeter according to e da!cati’ Ong inI Camarillo Ordinance Section 10.34.070. Ambient noise...sound levels associated. i1fth t. Mugu overflights over a 5-day period from 19-23 June, 1984. pssuremergx wereIrecorded with a claibrated noise dosimeter

  6. Results of SEI Independent Research and Development Projects and Report on Emerging Technologies and Technology Trends

    DTIC Science & Technology

    2004-10-01

    Top-Level Process for Identification and Analysis of Safety-Related Re- quirements 4.4 Collaborators The primary SEI team members were Don Firesmith...Graff, M. & van Wyk, K. Secure Coding Principles & Practices. O’Reilly, 2003. • Hoglund, G. & McGraw, G. Exploiting Software: How to Break Code. Addison...Eisenecker, U.; Glück, R.; Vandevoorde, D.; & Veldhuizen , T. “Generative Programming and Active Libraries (Extended Abstract)” <osl.iu.edu/~tveldhui/papers

  7. Optically stimulated luminescence dating of sediments

    NASA Astrophysics Data System (ADS)

    Troja, S. O.; Amore, C.; Barbagallo, G.; Burrafato, G.; Forzese, R.; Geremia, F.; Gueli, A. M.; Marzo, F.; Pirnaci, D.; Russo, M.; Turrisi, E.

    2000-04-01

    Optically stimulated luminescence (OSL) dating methodology was applied on the coarse grain fraction (100÷500 μm thick) of quartz crystals (green light stimulated luminescence, GLSL) and feldspar crystals (infrared stimulated luminescence, IRSL) taken from sections at different depths of cores bored in various coastal lagoons (Longarini, Cuba, Bruno) in the south-east coast of Sicily. The results obtained give a sequence of congruent relative ages and maximum absolute ages compatible with the sedimentary structure, thus confirming the excellent potential of the methodology.

  8. Adaptive Incentive Controls for Stackelberg Games with Unknown Cost Functionals.

    DTIC Science & Technology

    1984-01-01

    APR EZT:: F I AN 73S e OsL:-: UNCLASSI?:-- Q4~.’~- .A.., 6, *~*i i~~*~~*.- U ADAPTIVE INCENTIVE CONTROLS FOR STACKELBERG GAMES WITH UNKNOWN COST...AD-A161 885 ADAPTIVE INCENTIVE CONTROLS FOR STACKELBERG GAMES WITH i/1 UNKNOWN COST FUNCTIONALSCU) ILLINOIS UNIV AT URBANA DECISION AND CONTROL LAB T...ORGANIZATION 6b. OFFICE SYMBOL 7.. NAME OF MONITORING ORGANIZATION CoriaeLcenef~pda~ Joint Services Electronics Program Laboratory, Univ. of Illinois N/A

  9. An improved approach for flight readiness certification: Methodology for failure risk assessment and application examples. Volume 3: Structure and listing of programs

    NASA Technical Reports Server (NTRS)

    Moore, N. R.; Ebbeler, D. H.; Newlin, L. E.; Sutharshana, S.; Creager, M.

    1992-01-01

    An improved methodology for quantitatively evaluating failure risk of spaceflight systems to assess flight readiness and identify risk control measures is presented. This methodology, called Probabilistic Failure Assessment (PFA), combines operating experience from tests and flights with engineering analysis to estimate failure risk. The PFA methodology is of particular value when information on which to base an assessment of failure risk, including test experience and knowledge of parameters used in engineering analyses of failure phenomena, is expensive or difficult to acquire. The PFA methodology is a prescribed statistical structure in which engineering analysis models that characterize failure phenomena are used conjointly with uncertainties about analysis parameters and/or modeling accuracy to estimate failure probability distributions for specific failure modes. These distributions can then be modified, by means of statistical procedures of the PFA methodology, to reflect any test or flight experience. Conventional engineering analysis models currently employed for design of failure prediction are used in this methodology. The PFA methodology is described and examples of its application are presented. Conventional approaches to failure risk evaluation for spaceflight systems are discussed, and the rationale for the approach taken in the PFA methodology is presented. The statistical methods, engineering models, and computer software used in fatigue failure mode applications are thoroughly documented.

  10. 14 CFR 63.41 - Retesting after failure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Retesting after failure. 63.41 Section 63.41 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED... failure. An applicant for a flight engineer certificate who fails a written test or practical test for...

  11. 14 CFR 63.41 - Retesting after failure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Retesting after failure. 63.41 Section 63.41 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED... failure. An applicant for a flight engineer certificate who fails a written test or practical test for...

  12. 14 CFR 63.41 - Retesting after failure.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Retesting after failure. 63.41 Section 63.41 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED... failure. An applicant for a flight engineer certificate who fails a written test or practical test for...

  13. 14 CFR 63.41 - Retesting after failure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Retesting after failure. 63.41 Section 63.41 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED... failure. An applicant for a flight engineer certificate who fails a written test or practical test for...

  14. Ground Handling of Batteries at Test and Launch-site Facilities

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith A.; Hohl, Alan R.

    2008-01-01

    Ground handling of flight as well as engineering batteries at test facilities and launch-site facilities is a safety critical process. Test equipment interfacing with the batteries should have the required controls to prevent a hazardous failure of the batteries. Test equipment failures should not induce catastrophic failures on the batteries. Transportation requirements for batteries should also be taken into consideration for safe transportation. This viewgraph presentation includes information on the safe handling of batteries for ground processing at test facilities as well as launch-site facilities.

  15. Testing and failure analysis to improve screening techniques for hermetically sealed metallized film capacitors for low energy applications

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Effective screening techniques are evaluated for detecting insulation resistance degradation and failure in hermetically sealed metallized film capacitors used in applications where low capacitor voltage and energy levels are common to the circuitry. A special test and monitoring system capable of rapidly scanning all test capacitors and recording faults and/or failures is examined. Tests include temperature cycling and storage as well as low, medium, and high voltage life tests. Polysulfone film capacitors are more heat stable and reliable than polycarbonate film units.

  16. Flight test results of the strapdown ring laser gyro tetrad inertial navigation system

    NASA Technical Reports Server (NTRS)

    Carestia, R. A.; Hruby, R. J.; Bjorkman, W. S.

    1983-01-01

    A helicopter flight test program undertaken to evaluate the performance of Tetrad (a strap down, laser gyro, inertial navigation system) is described. The results of 34 flights show a mean final navigational velocity error of 5.06 knots, with a standard deviation of 3.84 knots; a corresponding mean final position error of 2.66 n. mi., with a standard deviation of 1.48 n. mi.; and a modeled mean position error growth rate for the 34 tests of 1.96 knots, with a standard deviation of 1.09 knots. No laser gyro or accelerometer failures were detected during the flight tests. Off line parity residual studies used simulated failures with the prerecorded flight test and laboratory test data. The airborne Tetrad system's failure--detection logic, exercised during the tests, successfully demonstrated the detection of simulated ""hard'' failures and the system's ability to continue successfully to navigate by removing the simulated faulted sensor from the computations. Tetrad's four ring laser gyros provided reliable and accurate angular rate sensing during the 4 yr of the test program, and no sensor failures were detected during the evaluation of free inertial navigation performance.

  17. On-clip high frequency reliability and failure test structures

    DOEpatents

    Snyder, E.S.; Campbell, D.V.

    1997-04-29

    Self-stressing test structures for realistic high frequency reliability characterizations. An on-chip high frequency oscillator, controlled by DC signals from off-chip, provides a range of high frequency pulses to test structures. The test structures provide information with regard to a variety of reliability failure mechanisms, including hot-carriers, electromigration, and oxide breakdown. The system is normally integrated at the wafer level to predict the failure mechanisms of the production integrated circuits on the same wafer. 22 figs.

  18. Metallographic and fractographic observations of posttest creep-fatigue specimens of weld-deposited Type 308 CRE stainless steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, M. W.

    Type 308 CRE stainless steel weld specimens were subjected to metallographic and fractographic analysis after failure in elevated-temperature (593/sup 0/C) creep-fatigue tests. The failure mode for specimens tested under continuous-cycle fatigue conditions was predominantly transgranular. When the test cycle was modified to include a hold time at the maximum tensile strain, the failure mode became predominantly interphase. Sigma phase was observed within the delta-ferrite regions in the weld. However, the presence of sigma phase did not appear to affect the failure mode.

  19. Development Testing and Subsequent Failure Investigation of a Spring Strut Mechanism

    NASA Technical Reports Server (NTRS)

    Dervan, Jared; Robertson, Brandan; Staab, Lucas; Culberson, Michael; Pellicciotti, Joseph

    2014-01-01

    The NASA Engineering and Safety Center (NESC) and Lockheed Martin (LM) performed random vibration testing on a single spring strut development unit to assess its ability to withstand qualification level random vibration environments. Failure of the strut while exposed to random vibration resulted in a follow-on failure investigation, design changes, and additional development tests. This paper focuses on the results of the failure investigations referenced in detail in the NESC final report [1] including identified lessons learned to aid in future design iterations of the spring strut and to help other mechanism developers avoid similar pitfalls.

  20. Development Testing and Subsequent Failure Investigation of a Spring Strut Mechanism

    NASA Technical Reports Server (NTRS)

    Dervan, Jared; Robertson, Brandon; Staab, Lucas; Culberson, Michael; Pellicciotti, Joseph

    2014-01-01

    The NASA Engineering and Safety Center (NESC) and Lockheed Martin (LM) performed random vibration testing on a single spring strut development unit to assess its ability to withstand qualification level random vibration environments. Failure of the strut while exposed to random vibration resulted in a follow-on failure investigation, design changes, and additional development tests. This paper focuses on the results of the failure investigations referenced in detail in the NESC final report including identified lessons learned to aid in future design iterations of the spring strut and to help other mechanism developers avoid similar pitfalls.

  1. HIV resistance testing and detected drug resistance in Europe.

    PubMed

    Schultze, Anna; Phillips, Andrew N; Paredes, Roger; Battegay, Manuel; Rockstroh, Jürgen K; Machala, Ladislav; Tomazic, Janez; Girard, Pierre M; Januskevica, Inga; Gronborg-Laut, Kamilla; Lundgren, Jens D; Cozzi-Lepri, Alessandro

    2015-07-17

    To describe regional differences and trends in resistance testing among individuals experiencing virological failure and the prevalence of detected resistance among those individuals who had a genotypic resistance test done following virological failure. Multinational cohort study. Individuals in EuroSIDA with virological failure (>1 RNA measurement >500 on ART after >6 months on ART) after 1997 were included. Adjusted odds ratios (aORs) for resistance testing following virological failure and aORs for the detection of resistance among those who had a test were calculated using logistic regression with generalized estimating equations. Compared to 74.2% of ART-experienced individuals in 1997, only 5.1% showed evidence of virological failure in 2012. The odds of resistance testing declined after 2004 (global P < 0.001). Resistance was detected in 77.9% of the tests, NRTI resistance being most common (70.3%), followed by NNRTI (51.6%) and protease inhibitor (46.1%) resistance. The odds of detecting resistance were lower in tests done in 1997-1998, 1999-2000 and 2009-2010, compared to those carried out in 2003-2004 (global P < 0.001). Resistance testing was less common in Eastern Europe [aOR 0.72, 95% confidence interval (CI) 0.55-0.94] compared to Southern Europe, whereas the detection of resistance given that a test was done was less common in Northern (aOR 0.29, 95% CI 0.21-0.39) and Central Eastern (aOR 0.47, 95% CI 0.29-0.76) Europe, compared to Southern Europe. Despite a concurrent decline in virological failure and testing, drug resistance was commonly detected. This suggests a selective approach to resistance testing. The regional differences identified indicate that policy aiming to minimize the emergence of resistance is of particular relevance in some European regions, notably in the countries in Eastern Europe.

  2. Aircraft control surface failure detection and isolation using the OSGLR test. [orthogonal series generalized likelihood ratio

    NASA Technical Reports Server (NTRS)

    Bonnice, W. F.; Motyka, P.; Wagner, E.; Hall, S. R.

    1986-01-01

    The performance of the orthogonal series generalized likelihood ratio (OSGLR) test in detecting and isolating commercial aircraft control surface and actuator failures is evaluated. A modification to incorporate age-weighting which significantly reduces the sensitivity of the algorithm to modeling errors is presented. The steady-state implementation of the algorithm based on a single linear model valid for a cruise flight condition is tested using a nonlinear aircraft simulation. A number of off-nominal no-failure flight conditions including maneuvers, nonzero flap deflections, different turbulence levels and steady winds were tested. Based on the no-failure decision functions produced by off-nominal flight conditions, the failure detection and isolation performance at the nominal flight condition was determined. The extension of the algorithm to a wider flight envelope by scheduling on dynamic pressure and flap deflection is examined. Based on this testing, the OSGLR algorithm should be capable of detecting control surface failures that would affect the safe operation of a commercial aircraft. Isolation may be difficult if there are several surfaces which produce similar effects on the aircraft. Extending the algorithm over the entire operating envelope of a commercial aircraft appears feasible.

  3. Strain isolated ceramic coatings

    NASA Technical Reports Server (NTRS)

    Tolokan, R. P.; Brady, J. B.; Jarrabet, G. P.

    1985-01-01

    Plasma sprayed ceramic coatings are used in gas turbine engines to improve component temperature capability and cooling air efficiency. A compliant metal fiber strain isolator between a plasma sprayed ceramic coating and a metal substrate improves ceramic durability while allowing thicker coatings for better insulation. Development of strain isolated coatings has concentrated on design and fabrication of coatings and coating evaluation via thermal shock testing. In thermal shock testing, five types of failure are possible: buckling failure im compression on heat up, bimetal type failure, isothermal expansion mismatch failure, mudflat cracking during cool down, and long term fatigue. A primary failure mode for thermally cycled coatings is designated bimetal type failure. Bimetal failure is tensile failure in the ceramic near the ceramic-metal interface. One of the significant benefits of the strain isolator is an insulating layer protecting the metal substrate from heat deformation and thereby preventing bimetal type failure.

  4. Investigating compression failure mechanisms in composite laminates with a transparent fiberglass-epoxy birefringent materials

    NASA Technical Reports Server (NTRS)

    Shuart, M. J.; Williams, J. G.

    1984-01-01

    The response and failure of a + or - 45s class laminate was studied by transparent fiberglass epoxy composite birefringent material. The birefringency property allows the laminate stress distribution to be observed during the test and also after the test if permanent residual stresses occur. The location of initial laminate failure and of the subsequent failure propagation are observed through its transparency characteristics. Experimental results are presented.

  5. An Empirical Approach to Logical Clustering of Software Failure Regions

    DTIC Science & Technology

    1994-03-01

    this is a coincidence or normal behavior of failure regions. " Software faults were numbered in order as they were discovered, by the various testing...locations of the associated faults. The goal of this research will be an improved testing technique that incorporates failure region behavior . To do this...clustering behavior . This, however, does not correlate with the structural clustering of failure regions observed by Ginn (1991) on the same set of data

  6. Analysis for the Progressive Failure Response of Textile Composite Fuselage Frames

    NASA Technical Reports Server (NTRS)

    Johnson, Eric R.; Boitnott, Richard L. (Technical Monitor)

    2002-01-01

    A part of aviation accident mitigation is a crash worthy airframe structure, and an important measure of merit for a crash worthy structure is the amount of kinetic energy that can be absorbed in the crush of the structure. Prediction of the energy absorbed from finite element analyses requires modeling the progressive failure sequence. Progressive failure modes may include material degradation, fracture and crack growth, and buckling and collapse. The design of crash worthy airframe components will benefit from progressive failure analyses that have been validated by tests. The subject of this research is the development of a progressive failure analysis for textile composite. circumferential fuselage frames subjected to a quasi-static, crash-type load. The test data for these frames are reported, and these data, along with stub column test data, are to be used to develop and to validate methods for the progressive failure response.

  7. Using the failure mode and effects analysis model to improve parathyroid hormone and adrenocorticotropic hormone testing

    PubMed Central

    Magnezi, Racheli; Hemi, Asaf; Hemi, Rina

    2016-01-01

    Background Risk management in health care systems applies to all hospital employees and directors as they deal with human life and emergency routines. There is a constant need to decrease risk and increase patient safety in the hospital environment. The purpose of this article is to review the laboratory testing procedures for parathyroid hormone and adrenocorticotropic hormone (which are characterized by short half-lives) and to track failure modes and risks, and offer solutions to prevent them. During a routine quality improvement review at the Endocrine Laboratory in Tel Hashomer Hospital, we discovered these tests are frequently repeated unnecessarily due to multiple failures. The repetition of the tests inconveniences patients and leads to extra work for the laboratory and logistics personnel as well as the nurses and doctors who have to perform many tasks with limited resources. Methods A team of eight staff members accompanied by the Head of the Endocrine Laboratory formed the team for analysis. The failure mode and effects analysis model (FMEA) was used to analyze the laboratory testing procedure and was designed to simplify the process steps and indicate and rank possible failures. Results A total of 23 failure modes were found within the process, 19 of which were ranked by level of severity. The FMEA model prioritizes failures by their risk priority number (RPN). For example, the most serious failure was the delay after the samples were collected from the department (RPN =226.1). Conclusion This model helped us to visualize the process in a simple way. After analyzing the information, solutions were proposed to prevent failures, and a method to completely avoid the top four problems was also developed. PMID:27980440

  8. Sensitivity, Specificity, Predictive Values, and Accuracy of Three Diagnostic Tests to Predict Inferior Alveolar Nerve Blockade Failure in Symptomatic Irreversible Pulpitis

    PubMed Central

    Rodríguez-Wong, Laura; Noguera-González, Danny; Esparza-Villalpando, Vicente; Montero-Aguilar, Mauricio

    2017-01-01

    Introduction The inferior alveolar nerve block (IANB) is the most common anesthetic technique used on mandibular teeth during root canal treatment. Its success in the presence of preoperative inflammation is still controversial. The aim of this study was to evaluate the sensitivity, specificity, predictive values, and accuracy of three diagnostic tests used to predict IANB failure in symptomatic irreversible pulpitis (SIP). Methodology A cross-sectional study was carried out on the mandibular molars of 53 patients with SIP. All patients received a single cartridge of mepivacaine 2% with 1 : 100000 epinephrine using the IANB technique. Three diagnostic clinical tests were performed to detect anesthetic failure. Anesthetic failure was defined as a positive painful response to any of the three tests. Sensitivity, specificity, predictive values, accuracy, and ROC curves were calculated and compared and significant differences were analyzed. Results IANB failure was determined in 71.7% of the patients. The sensitivity scores for the three tests (lip numbness, the cold stimuli test, and responsiveness during endodontic access) were 0.03, 0.35, and 0.55, respectively, and the specificity score was determined as 1 for all of the tests. Clinically, none of the evaluated tests demonstrated a high enough accuracy (0.30, 0.53, and 0.68 for lip numbness, the cold stimuli test, and responsiveness during endodontic access, resp.). A comparison of the areas under the curve in the ROC analyses showed statistically significant differences between the three tests (p < 0.05). Conclusion None of the analyzed tests demonstrated a high enough accuracy to be considered a reliable diagnostic tool for the prediction of anesthetic failure. PMID:28694714

  9. Hybrid Bearing Prognostic Test Rig

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Certo, Joseph M.; Handschuh, Robert F.; Dimofte, Florin

    2005-01-01

    The NASA Glenn Research Center has developed a new Hybrid Bearing Prognostic Test Rig to evaluate the performance of sensors and algorithms in predicting failures of rolling element bearings for aeronautics and space applications. The failure progression of both conventional and hybrid (ceramic rolling elements, metal races) bearings can be tested from fault initiation to total failure. The effects of different lubricants on bearing life can also be evaluated. Test conditions monitored and recorded during the test include load, oil temperature, vibration, and oil debris. New diagnostic research instrumentation will also be evaluated for hybrid bearing damage detection. This paper summarizes the capabilities of this new test rig.

  10. Demonstrating the Safety and Reliability of a New System or Spacecraft: Incorporating Analyses and Reviews of the Design and Processing in Determining the Number of Tests to be Conducted

    NASA Technical Reports Server (NTRS)

    Vesely, William E.; Colon, Alfredo E.

    2010-01-01

    Design Safety/Reliability is associated with the probability of no failure-causing faults existing in a design. Confidence in the non-existence of failure-causing faults is increased by performing tests with no failure. Reliability-Growth testing requirements are based on initial assurance and fault detection probability. Using binomial tables generally gives too many required tests compared to reliability-growth requirements. Reliability-Growth testing requirements are based on reliability principles and factors and should be used.

  11. Ply-level failure analysis of a graphite/epoxy laminate under bearing-bypass loading

    NASA Technical Reports Server (NTRS)

    Naik, R. A.; Crews, J. H., Jr.

    1988-01-01

    A combined experimental and analytical study was conducted to investigate and predict the failure modes of a graphite/epoxy laminate subjected to combined bearing and bypass loading. Tests were conducted in a test machine that allowed the bearing-bypass load ratio to be controlled while a single-fastener coupon was loaded to failure in either tension or compression. Onset and ultimate failure modes and strengths were determined for each test case. The damage-onset modes were studied in detail by sectioning and micrographing the damaged specimens. A two-dimensional, finite-element analysis was conducted to determine lamina strains around the bolt hole. Damage onset consisted of matrix cracks, delamination, and fiber failures. Stiffness loss appeared to be caused by fiber failures rather than by matrix cracking and delamination. An unusual offset-compression mode was observed for compressive bearing-bypass laoding in which the specimen failed across its width along a line offset from the hole. The computed lamina strains in the fiber direction were used in a combined analytical and experimental approach to predict bearing-bypass diagrams for damage onset from a few simple tests.

  12. Ply-level failure analysis of a graphite/epoxy laminate under bearing-bypass loading

    NASA Technical Reports Server (NTRS)

    Naik, R. A.; Crews, J. H., Jr.

    1990-01-01

    A combined experimental and analytical study was conducted to investigate and predict the failure modes of a graphite/epoxy laminate subjected to combined bearing and bypass loading. Tests were conducted in a test machine that allowed the bearing-bypass load ratio to be controlled while a single-fastener coupon was loaded to failure in either tension or compression. Onset and ultimate failure modes and strengths were determined for each test case. The damage-onset modes were studied in detail by sectioning and micrographing the damaged specimens. A two-dimensional, finite-element analysis was conducted to determine lamina strains around the bolt hole. Damage onset consisted of matrix cracks, delamination, and fiber failures. Stiffness loss appeared to be caused by fiber failures rather than by matrix cracking and delamination. An unusual offset-compression mode was observed for compressive bearing-bypass loading in which the specimen failed across its width along a line offset from the hole. The computed lamina strains in the fiber direction were used in a combined analytical and experimental approach to predict bearing-bypass diagrams for damage onset from a few simple tests.

  13. Application of fiber grating-based acoustic sensor in progressive failure testing of e-glass/vinylester curve composites

    NASA Astrophysics Data System (ADS)

    Azmi, Asrul Izam; Raju, Raju; Peng, Gang-Ding

    2012-02-01

    This paper reports an application of phase shifted fiber Bragg grating (PS-FBG) intensity-type acoustic sensor in a continuous and in-situ failure testing of an E-glass/vinylester top hat stiffener (THS). The narrow transmission channel of the PS-FBG is highly sensitive to small perturbation, hence suitable to be used in an effective acoustic emission (AE) assessment technique. The progressive failure of THS was tested under transverse loading to experimentally simulate the actual loading in practice. Our experimental tests have demonstrated, in good agreement with the commercial piezoelectric sensors, that the important failures information of the THS was successfully recorded by the simple intensity-type PS-FBG sensor.

  14. Experimental and theoretical investigation of fatigue life in reusable rocket thrust chambers

    NASA Technical Reports Server (NTRS)

    Hannum, N. P.; Kasper, H. J.; Pavli, A. J.

    1976-01-01

    During a test program to investigate low-cycle thermal fatigue, 13 rocket combustion chambers were fabricated and cyclically test fired to failure. Six oxygen-free, high-conductivity (OFHC) copper and seven Amzirc chambers were tested. The failures in the OFHC copper chambers were not typical fatigue failures but are described as creep rupture enhanced by ratcheting. The coolant channels bulged toward the chamber centerline, resulting in progressive thinning of the wall during each cycle. The failures in the Amzirc alloy chambers were caused by low-cycle thermal fatigue. The zirconium in this alloy was not evenly distributed in the chamber materials. The life that was achieved was nominally the same as would have been predicted from OFHC copper isothermal test data.

  15. Investigation on bending failure to characterize crashworthiness of 6xxx-series aluminium sheet alloys with bending-tension test procedure

    NASA Astrophysics Data System (ADS)

    Henn, Philipp; Liewald, Mathias; Sindel, Manfred

    2018-05-01

    As lightweight design as well as crash performance are crucial to future car body design, exact material characterisation is important to use materials at their full potential and reach maximum efficiency. Within the scope of this paper, the potential of newly established bending-tension test procedure to characterise material crashworthiness is investigated. In this test setup for the determination of material failure, a buckling-bending test is coupled with a subsequent tensile test. If prior bending load is critical, tensile strength and elongation in the subsequent tensile test are dramatically reduced. The new test procedure therefore offers an applicable definition of failure as the incapacity of energy consumption in subsequent phases of the crash represents failure of a component. In addition to that, the correlation of loading condition with actual crash scenarios (buckling and free bending) is improved compared to three- point bending test. The potential of newly established bending-tension test procedure to characterise material crashworthiness is investigated in this experimental studys on two aluminium sheet alloys. Experimental results are validated with existing ductility characterisation from edge compression test.

  16. Drought drove forest decline and dune building in eastern upper Michigan, USA, as the upper Great Lakes became closed basins

    USGS Publications Warehouse

    Loope, Walter L.; Loope, Henry M.; Goble, Ronald J.; Fisher, Timothy G.; Lytle, David E.; Legg, Robert J.; Wysocki, Douglas A.; Hanson, Paul R.; Young, Aaron R.

    2012-01-01

    Current models of landscape response to Holocene climate change in midcontinent North America largely reconcile Earth orbital and atmospheric climate forcing with pollen-based forest histories on the east and eolian chronologies in Great Plains grasslands on the west. However, thousands of sand dunes spread across 12,000 km2 in eastern upper Michigan (EUM), more than 500 km east of the present forest-prairie ecotone, present a challenge to such models. We use 65 optically stimulated luminescence (OSL) ages on quartz sand deposited in silt caps (n = 8) and dunes (n = 57) to document eolian activity in EUM. Dune building was widespread ca. 10–8 ka, indicating a sharp, sustained decline in forest cover during that period. This decline was roughly coincident with hydrologic closure of the upper Great Lakes, but temporally inconsistent with most pollen-based models that imply canopy closure throughout the Holocene. Early Holocene forest openings are rarely recognized in pollen sums from EUM because faint signatures of non-arboreal pollen are largely obscured by abundant and highly mobile pine pollen. Early Holocene spikes in nonarboreal pollen are recorded in cores from small ponds, but suggest only a modest extent of forest openings. OSL dating of dune emplacement provides a direct, spatially explicit archive of greatly diminished forest cover during a very dry climate in eastern midcontinent North America ca. 10–8 ka.

  17. Relative optically stimulated luminescence and thermoluminescence efficiencies of Al2O3:C dosimeters to heavy charged particles with energies relevant to space and radiotherapy dosimetry

    NASA Astrophysics Data System (ADS)

    Sawakuchi, G. O.; Yukihara, E. G.; McKeever, S. W. S.; Benton, E. R.; Gaza, R.; Uchihori, Y.; Yasuda, N.; Kitamura, H.

    2008-12-01

    This article presents a comprehensive characterization of the thermoluminescence (TL) and optically stimulated luminescence (OSL) relative luminescence efficiencies of carbon-doped aluminum (Al2O3:C) for heavy charged particles (HCPs) with atomic numbers ranging from 1 (proton) to 54 (xenon) and energies ranging from 7 to 1000 MeV/u, and investigates the dependence of the Al2O3:C response on experimental conditions. Relative luminescence efficiency values are presented for 19 primary charge/energy combinations, plus 31 additional charge/energy combinations obtained by introducing absorbers in the primary beam. Our results show that for energies of hundreds of MeV/u the data can be described by a single curve of relative luminescence efficiency versus linear energy transfer (LET). This information is needed to compensate for the reduced OSL efficiency to high-LET particles in such applications as space dosimetry. For lower energies, the relative luminescence efficiency as function of LET cannot be described by a single curve; instead, it separates into different components corresponding to different particles. We also present data on the low-LET dose response of Al2O3:C, measured under the same experimental conditions in which the relative luminescence efficiencies to HCPs were obtained, providing information relevant to future theoretical investigations of HCP energy deposition and luminescence production in Al2O3:C.

  18. MO-A-BRB-01: TG191: Clinical Use of Luminescent Dosimeters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kry, S.

    This presentation will highlight the upcoming TG-191 report: Clinical Use of Luminescent Dosimeters. Luminescent dosimetry based on TLD and OSLD is a practical, accurate, and precise technique for point dosimetry in medical physics applications. The charges of Task Group 191 were to detail the methodologies for practical and optimal luminescent dosimetry in a clinical setting. This includes (1) To review the variety of TLD/OSL materials available, including features and limitations of each. (2) To outline the optimal steps to achieve accurate and precise dosimetry with luminescent detectors and to evaluate the uncertainty induced when less rigorous procedures are used. (3)more » To develop consensus guidelines on the optimal use of luminescent dosimeters for clinical practice. (4) To develop guidelines for special medically relevant uses of TLDs/OSLs (e.g., mixed field i.e. photon/neutron dosimetry, particle beam dosimetry, skin dosimetry). While this report provides general guidelines for arbitrary TLD and OSLD processes, the report, and therefore this presentation, provide specific guidance for TLD-100 (LiF:Ti,Mg) and nanoDot (Al2O3:C) dosimeters because of their prevalence in clinical practice. Learning Objectives: Understand the available dosimetry systems, and basic theory of their operation Understand the range of dose determination methodologies and the uncertainties associated with them Become familiar with special considerations for TLD/OSLD relevant for special clinical situations Learn recommended commissioning and QA procedures for these dosimetry systems.« less

  19. The use of stimulated electron emission (SEE) in homeland security applications

    NASA Astrophysics Data System (ADS)

    Ing, H.; Andrews, H. R.; Facina, M.; Lee, W. T.; Niu, H. W.

    2012-06-01

    Certain insulating solids can store a fraction of the absorbed energy when irradiated by ionizing radiation. The stored energy can be released subsequently by heating or optical stimulation. As a result, light may be emitted through Thermoluminescence (TL) or Optically-Stimulated Luminescence (OSL) and electrons may be emitted through Thermally-Stimulated Electron Emission (TSEE) or Optically-Stimulated Electron Emission (OSEE). TL and OSL are widely used in current radiation dosimetry systems. However, despite considerable research effort during the early 1970s, SEE was not commonly adopted for dosimetry applications. One of the main reasons is that SEE is a surface phenomenon, while luminescence is a bulk phenomenon, making SEE more susceptible to humidity, absorption of gases, minor physical defects and handling, both before and after irradiation. Nevertheless, it has been recognized that SEE may be useful for homeland security applications in nuclear forensics, where dose accuracy is not the primary performance metric. In this research, we are investigating the use of SEE for nuclear forensic applications. Many common materials, both natural and man-made, exhibit the phenomenon, providing an opportunity to use the environment itself as an in-situ radiation detector. We have designed and constructed a unique prototype reader for conducting SEE measurements. We have demonstrated that the SEE measurements from a variety of materials are quantitatively reproducible and correlated to radiation exposure. Due to the broad applicability of SEE, significant additional studies are warranted to optimize this novel technique for nuclear forensic and other applications.

  20. MO-A-BRB-00: TG191: Clinical Use of Luminescent Dosimeters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This presentation will highlight the upcoming TG-191 report: Clinical Use of Luminescent Dosimeters. Luminescent dosimetry based on TLD and OSLD is a practical, accurate, and precise technique for point dosimetry in medical physics applications. The charges of Task Group 191 were to detail the methodologies for practical and optimal luminescent dosimetry in a clinical setting. This includes (1) To review the variety of TLD/OSL materials available, including features and limitations of each. (2) To outline the optimal steps to achieve accurate and precise dosimetry with luminescent detectors and to evaluate the uncertainty induced when less rigorous procedures are used. (3)more » To develop consensus guidelines on the optimal use of luminescent dosimeters for clinical practice. (4) To develop guidelines for special medically relevant uses of TLDs/OSLs (e.g., mixed field i.e. photon/neutron dosimetry, particle beam dosimetry, skin dosimetry). While this report provides general guidelines for arbitrary TLD and OSLD processes, the report, and therefore this presentation, provide specific guidance for TLD-100 (LiF:Ti,Mg) and nanoDot (Al2O3:C) dosimeters because of their prevalence in clinical practice. Learning Objectives: Understand the available dosimetry systems, and basic theory of their operation Understand the range of dose determination methodologies and the uncertainties associated with them Become familiar with special considerations for TLD/OSLD relevant for special clinical situations Learn recommended commissioning and QA procedures for these dosimetry systems.« less

Top