Sample records for therapy total dose

  1. Maximum dose rate is a determinant of hypothyroidism after 131I therapy of Graves' disease but the total thyroid absorbed dose is not.

    PubMed

    Krohn, Thomas; Hänscheid, Heribert; Müller, Berthold; Behrendt, Florian F; Heinzel, Alexander; Mottaghy, Felix M; Verburg, Frederik A

    2014-11-01

    The determinants of successful (131)I therapy of Graves' disease (GD) are unclear. To relate dosimetry parameters to outcome of therapy to identify significant determinants eu- and/or hypothyroidism after (131)I therapy in patients with GD. A retrospective study in which 206 Patients with GD treated in University Hospital between November 1999 and January 2011. All received (131)I therapy aiming at a total absorbed dose to the thyroid of 250 Gy based on pre-therapeutic dosimetry. Post-therapy dosimetric thyroid measurements were performed twice daily until discharge. From these measurements, thyroid (131)I half-life, the total thyroid absorbed dose, and the maximum dose rate after (131)I administration were calculated. In all, 48.5% of patients were hypothyroid and 28.6% of patients were euthyroid after (131)I therapy. In univariate analysis, nonhyperthyroid and hyperthyroid patients only differed by sex. A lower thyroid mass, a higher activity per gram thyroid tissue, a shorter effective thyroidal (131)I half-life, and a higher maximum dose rate, but not the total thyroid absorbed dose, were significantly associated with hypothyroidism. In multivariate analysis, the maximum dose rate remained the only significant determinant of hypothyroidism (P < .001). Maximum dose rates of 2.2 Gy/h and higher were associated with a 100% hypothyroidism rate. Not the total thyroid absorbed dose, but the maximum dose rate is a determinant of successfully achieving hypothyroidism in Graves' disease. Dosimetric concepts aiming at a specific total thyroid absorbed dose will therefore require reconsideration if our data are confirmed prospectively.

  2. Rates of Change in Naturalistic Psychotherapy: Contrasting Dose-Effect and Good-Enough Level Models of Change

    ERIC Educational Resources Information Center

    Baldwin, Scott A.; Berkeljon, Arjan; Atkins, David C.; Olsen, Joseph A.; Nielsen, Stevan L.

    2009-01-01

    Most research on the dose-effect model of change has combined data across patients who vary in their total dose of treatment and has implicitly assumed that the rate of change during therapy is constant across doses. In contrast, the good-enough level model predicts that rate of change will be related to total dose of therapy. In this study, the…

  3. Hydrocortisone Therapy in Catecholamine-Resistant Pediatric Septic Shock: A Pragmatic Analysis of Clinician Practice and Association With Outcomes.

    PubMed

    Nichols, Blake; Kubis, Sherri; Hewlett, Jennifer; Yehya, Nadir; Srinivasan, Vijay

    2017-09-01

    The 2012 Surviving Sepsis Campaign pediatric guidelines recommend stress dose hydrocortisone in children experiencing catecholamine-dependent septic shock with suspected or proven absolute adrenal insufficiency. We evaluated whether stress dose hydrocortisone therapy in children with catecholamine dependent septic shock correlated with random serum total cortisol levels and was associated with improved outcomes. Retrospective cohort study. Non-cardiac PICU. Critically ill children (1 mo to 18 yr) admitted between January 1, 2013, and December 31, 2013, with catecholamine dependent septic shock who had random serum total cortisol levels measured prior to potential stress dose hydrocortisone therapy. None. The cohort was dichotomized to random serum total cortisol less than 18 mcg/dL and greater than or equal to 18 mcg/dL. Associations of stress dose hydrocortisone with outcomes: PICU mortality, PICU and hospital length of stay, ventilator-free days, and vasopressor-free days were examined. Seventy children with catecholamine-dependent septic shock and measured random serum total cortisol levels were eligible (16% PICU mortality). Although 43% (30/70) had random serum total cortisol less than 18 μg/dL, 60% (42/70) received stress dose hydrocortisone. Children with random serum total cortisol less than 18 μg/dL had lower severity of illness and lower Vasopressor Inotrope Scores than those with random serum total cortisol greater than or equal to 18 μg/dL (all p < 0.05). Children with stress dose hydrocortisone had higher severity of illness and PICU mortality than those without stress dose hydrocortisone (all p < 0.05). Mean random serum total cortisol levels were similar in children with and without stress dose hydrocortisone (21.1 vs 18.7 μg/dL; p = 0.69). In children with random serum total cortisol less than 18 μg/dL, stress dose hydrocortisone was associated with greater PICU and hospital length of stay and fewer ventilator-free days (all p < 0.05). In children with random serum total cortisol greater than 18 μg/dL, stress dose hydrocortisone was associated with greater PICU mortality and fewer ventilator-free days and vasopressor-free days (all p < 0.05). Stress dose hydrocortisone therapy in children with catecholamine-dependent septic shock correlated more with severity of illness than random serum total cortisol levels and was associated with worse outcomes, irrespective of random serum total cortisol levels.

  4. Four-Dimensional Patient Dose Reconstruction for Scanned Ion Beam Therapy of Moving Liver Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richter, Daniel; TU Darmstadt, Darmstadt; Saito, Nami

    2014-05-01

    Purpose: Estimation of the actual delivered 4-dimensional (4D) dose in treatments of patients with mobile hepatocellular cancer with scanned carbon ion beam therapy. Methods and Materials: Six patients were treated with 4 fractions to a total relative biological effectiveness (RBE)–weighted dose of 40 Gy (RBE) using a single field. Respiratory motion was addressed by dedicated margins and abdominal compression (5 patients) or gating (1 patient). 4D treatment dose reconstructions based on the treatment records and the measured motion monitoring data were performed for the single-fraction dose and a total of 17 fractions. To assess the impact of uncertainties in the temporalmore » correlation between motion trajectory and beam delivery sequence, 3 dose distributions for varying temporal correlation were calculated per fraction. For 3 patients, the total treatment dose was formed from the fractional distributions using all possible combinations. Clinical target volume (CTV) coverage was analyzed using the volumes receiving at least 95% (V{sub 95}) and 107% (V{sub 107}) of the planned doses. Results: 4D dose reconstruction based on daily measured data is possible in a clinical setting. V{sub 95} and V{sub 107} values for the single fractions ranged between 72% and 100%, and 0% and 32%, respectively. The estimated total treatment dose to the CTV exhibited improved and more robust dose coverage (mean V{sub 95} > 87%, SD < 3%) and overdose (mean V{sub 107} < 4%, SD < 3%) with respect to the single-fraction dose for all analyzed patients. Conclusions: A considerable impact of interplay effects on the single-fraction CTV dose was found for most of the analyzed patients. However, due to the fractionated treatment, dose heterogeneities were substantially reduced for the total treatment dose. 4D treatment dose reconstruction for scanned ion beam therapy is technically feasible and may evolve into a valuable tool for dose assessment.« less

  5. Stochastic Predictions of Cell Kill During Stereotactic Ablative Radiation Therapy: Do Hypoxia and Reoxygenation Really Matter?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harriss-Phillips, Wendy M., E-mail: wharrphil@gmail.com; School of Chemistry and Physics, University of Adelaide, Adelaide, South Australia; Bezak, Eva

    Purpose: To simulate stereotactic ablative radiation therapy on hypoxic and well-oxygenated in silico tumors, incorporating probabilistic parameter distributions and linear-quadratic versus linear-quadratic-cubic methodology and the evaluation of optimal fractionation schemes using biological effective dose (BED{sub α/β=10} {sub or} {sub 3}) comparisons. Methods and Materials: A temporal tumor growth and radiation therapy algorithm simulated high-dose external beam radiation therapy using stochastic methods. Realistic biological proliferative cellular hierarchy and pO{sub 2} histograms were incorporated into the 10{sup 8}-cell tumor model, with randomized radiation therapy applied during continual cell proliferation and volume-based gradual tumor reoxygenation. Dose fractions ranged from 6-35 Gy, with predictive outcomes presentedmore » in terms of the total doses (converted to BED) required to eliminate all cells that could potentially regenerate the tumor. Results: Well-oxygenated tumor control BED{sub 10} outcomes were not significantly different for high-dose versus conventional radiation therapy (BED{sub 10}: 79-84 Gy; Equivalent Dose in 2 Gy fractions with α/β of 10: 66-70 Gy); however, total treatment times decreased from 7 down to 1-3 weeks. For hypoxic tumors, an additional 28 Gy (51 Gy BED{sub 10}) was required, with BED{sub 10} increasing with dose per fraction due to wasted dose in the final fraction. Fractions of 9 Gy compromised well for total treatment time and BED, with BED{sub 10}:BED{sub 3} of 84:176 Gy for oxic and 132:278 Gy for non-reoxygenating hypoxic tumors. Initial doses of 12 Gy followed by 6 Gy further increased the therapeutic ratio. When delivering ≥9 Gy per fraction, applying reoxygenation and/or linear-quadratic-cubic cell survival both affected tumor control doses by a significant 1-2 fractions. Conclusions: The complex temporal dynamics of tumor oxygenation combined with probabilistic cell kinetics in the modeling of radiation therapy requires sophisticated stochastic modeling to predict tumor cell kill. For stereotactic ablative radiation therapy, high doses in the first week followed by doses that are more moderate may be beneficial because a high percentage of hypoxic cells could be eradicated early while keeping the required BED{sub 10} relatively low and BED{sub 3} toxicity to tolerable levels.« less

  6. Helical irradiation of the total skin with dose painting to replace total skin electron beam therapy for therapy-refractory cutaneous CD4+ T-cell lymphoma.

    PubMed

    Hsieh, Chen-Hsi; Shueng, Pei-Wei; Lin, Shih-Chiang; Tien, Hui-Ju; Shiau, An-Cheng; Chou, Yueh-Hung; Wu, Meng-Hao; Wang, Jen-Yu; Chen, Chi-Kuan; Chen, Yu-Jen

    2013-01-01

    A 36-year-old woman was diagnosed with a therapy-refractory cutaneous CD4+ T-cell lymphoma, T3N0M0B0, and stage IIB. Helical irradiation of the total skin (HITS) and dose painting techniques, with 30 Gy in 40 fractions interrupted at 20 fractions with one week resting, 4 times per week were prescribed. The diving suit was dressed whole body to increase the superficial dose and using central core complete block (CCCB) technique for reducing the internal organ dose. The mean doses of critical organs of head, chest, and abdomen were 2.1 to 29.9 Gy, 2.9 to 8.1 Gy, and 3.6 to 15.7 Gy, respectively. The mean dose of lesions was 84.0 cGy. The dosage of left side pretreated area was decreased 57%. The tumor regressed progressively without further noduloplaques. During the HITS procedure, most toxicity was grade I except leukocytopenia with grade 3. No epitheliolysis, phlyctenules, tumor lysis syndrome, fever, vomiting, dyspnea, edema of the extremities, or diarrhea occurred during the treatment. HITS with dose painting techniques provides precise dosage delivery with impressive results, sparing critical organs, and offering limited transient and chronic sequelae for previously locally irradiated, therapy-refractory cutaneous T-cell lymphoma.

  7. Clinical outcomes and cost minimization with an alternative dosing regimen for meropenem in a community hospital.

    PubMed

    Patel, Gita Wasan; Duquaine, Susan M; McKinnon, Peggy S

    2007-12-01

    To compare outcomes and cost for the traditional United States Food and Drug Administration-approved dosing regimen for meropenem versus an alternative dosing regimen providing similar pharmacodynamic exposure with a lower total daily dose. Retrospective cohort study with a cost-minimization analysis. A 417-bed, privately owned community hospital. One hundred patients who received meropenem 1 g every 8 or 12 hours (traditional dosing regimen) between January 1 and September 30, 2004 (historical controls), and 192 patients who received meropenem 500 mg every 6 or 8 hours (alternative dosing regimen) between October 1, 2004, and September 30, 2005. Demographic and clinical data were collected for all patients. Cost-minimization analysis was performed by using the drug acquisition cost for meropenem. Demographics, sources of infection, distributions of organisms, and Charlson Comorbidity Index scores were similar between patients in the traditionally and alternatively dosed groups. Concomitant therapy, duration of therapy, success rates, lengths of stay, and in-hospital mortality rates were also similar between groups. Median time to the resolution of symptoms was 3 days for traditional dosing and 1.5 days for alternative dosing (p<0.0001). A logistic regression model including the dosing strategy showed that only polymicrobial infections and sepsis were associated with increased failure rates. The median cost for antibiotics was $439.05/patient for traditional dosing and $234.08/patient for alternative dosing (p<0.0001). An alternative dosing regimen for meropenem with a lower total daily dose yielded patient outcomes, including success rates and duration of therapy, equivalent to those of the traditional dosing regimen. Alternative dosing decreased total drug exposure, costs for antibiotics, and time to the resolution of infections.

  8. Single-dose radiation therapy for prevention of heterotopic ossification after total hip arthroplasty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Healy, W.L.; Lo, T.C.; Covall, D.J.

    1990-12-01

    Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700more » centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy.« less

  9. Carbon-Ion Radiation Therapy for Pelvic Recurrence of Rectal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamada, Shigeru, E-mail: s_yamada@nirs.go.jp; Kamada, Tadashi; Ebner, Daniel K.

    Purpose: Investigation of the treatment potential of carbon-ion radiation therapy in pelvic recurrence of rectal cancer. Methods and Materials: A phase 1/2 dose escalation study was performed. One hundred eighty patients (186 lesions) with locally recurrent rectal cancer were treated with carbon-ion radiation therapy (CIRT) (phase 1/2: 37 and 143 patients, respectively). The relapse locations were 71 in the presacral region, 82 in the pelvic sidewalls, 28 in the perineum, and 5 near the colorectal anastomosis. A 16-fraction in 4 weeks dose regimen was used, with total dose ranging from 67.2 to 73.6 Gy(RBE); RBE-weighted absorbed dose: 4.2 to 4.6 Gy(RBE)/fraction. Results: Duringmore » phase 1, the highest total dose, 73.6 Gy(RBE), resulted in no grade >3 acute reactions in the 13 patients treated at that dose. Dose escalation was halted at this level, and this dose was used for phase 2, with no other grade >3 acute reactions observed. At 5 years, the local control and survival rates at 73.6 Gy(RBE) were 88% (95% confidence interval [CI], 80%-93%) and 59% (95% CI, 50%-68%), respectively. Conclusion: Carbon-ion radiation therapy may be a safe and effective treatment option for locally recurrent rectal cancer and may serve as an alternative to surgery.« less

  10. Relevant tumor sink effect in prostate cancer patients receiving 177Lu-PSMA-617 radioligand therapy.

    PubMed

    Filss, Christian; Heinzel, Alexander; Miiller, Berthold; Vogg, Andreas T J; Langen, Karl-Josef; Mottaghy, Felix M

    2018-02-01

    In metastatic prostate cancer patients PSMA targeting radioligands have gained significant impact as theranostic probes. In this study a correlation between total tumor volume (TTV) and measured kidney dose as well as salivary glands (SG) uptake in 177 Lu-PSMA-617 therapy was evaluated. Eleven consecutive prostate cancer patients receiving a first cylcle of 177 Lu-PSMA-617 (administered activity of approximately 6GBq) were included. The 68 Ga-PSMA-11 PET/CT scan previous to therapy was used to determine TTV and SG uptake (glandulae submandibularis) employing PMOD version 3.403 with different 68 Ga-PSMA-11 thresholds based on the standardized uptake value (SUV).The kidney dose was estimated with the software ULMDOS using planar whole-body scintigrams. Kidney dose and SG uptake was inversely correlated to TTV, indicating high kidney dose and high SG uptake in case of low tumor load and low kidney dose and low SG uptake in case of high tumor load. Our data support the hypothesis that in 177 Lu-PSMA-617 therapy an individualized treatment activity based on total tumor volume could be beneficiary. Schattauer GmbH.

  11. A comprehensive dosimetric study of pancreatic cancer treatment using three-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiation therapy (IMRT), volumetric-modulated radiation therapy (VMAT), and passive-scattering and modulated-scanning proton therapy (PT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Xuanfeng; Dionisi, Francesco; Tang, Shikui

    With traditional photon therapy to treat large postoperative pancreatic target volume, it often leads to poor tolerance of the therapy delivered and may contribute to interrupted treatment course. This study was performed to evaluate the potential advantage of using passive-scattering (PS) and modulated-scanning (MS) proton therapy (PT) to reduce normal tissue exposure in postoperative pancreatic cancer treatment. A total of 11 patients with postoperative pancreatic cancer who had been previously treated with PS PT in University of Pennsylvania Roberts Proton Therapy Center from 2010 to 2013 were identified. The clinical target volume (CTV) includes the pancreatic tumor bed as wellmore » as the adjacent high-risk nodal areas. Internal (iCTV) was generated from 4-dimensional (4D) computed tomography (CT), taking into account target motion from breathing cycle. Three-field and 4-field 3D conformal radiation therapy (3DCRT), 5-field intensity-modulated radiation therapy, 2-arc volumetric-modulated radiation therapy, and 2-field PS and MS PT were created on the patients’ average CT. All the plans delivered 50.4 Gy to the planning target volume (PTV). Overall, 98% of PTV was covered by 95% of the prescription dose and 99% of iCTV received 98% prescription dose. The results show that all the proton plans offer significant lower doses to the left kidney (mean and V{sub 18} {sub Gy}), stomach (mean and V{sub 20} {sub Gy}), and cord (maximum dose) compared with all the photon plans, except 3-field 3DCRT in cord maximum dose. In addition, MS PT also provides lower doses to the right kidney (mean and V{sub 18} {sub Gy}), liver (mean dose), total bowel (V{sub 20} {sub Gy} and mean dose), and small bowel (V{sub 15} {sub Gy} absolute volume ratio) compared with all the photon plans and PS PT. The dosimetric advantage of PT points to the possibility of treating tumor bed and comprehensive nodal areas while providing a more tolerable treatment course that could be used for dose escalation and combining with radiosensitizing chemotherapy.« less

  12. Bronchoscopic phototherapy at comparable dose rates: Early results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pass, H.I.; Delaney, T.; Smith, P.D.

    1989-05-01

    Photodynamic therapy is a recently introduced treatment for surface malignancies. Since January 1987, 10 patients with endobronchial neoplasms have had bronchoscopic photodynamic therapy at similar dose rates (400 mW/cm) for total atelectasis (2), carinal narrowing with respiratory insufficiency (2), or partial obstruction without collapse (4). Two patients underwent photodynamic therapy as a preliminary to immunotherapy. Histologies included endobronchial metastases (colon, ovary, melanoma, and sarcoma, 1 each; and renal cell, 3) and primary lung cancer (3). The 2 patients with total atelectasis had complete reexpansion after photodynamic therapy, which permitted eventual sleeve lobectomy in 1. Carinal narrowing was ameliorated in themore » 2 patients seen with inspiratory stridor, thereby permitting hospital discharge. Endoscopically resected fragments after photodynamic therapy exhibited avascular necrosis. These data support further controlled studies of photodynamic therapy by thoracic surgical oncologists to define its limitations as well as to improve and expand its efficacy as a palliative or surgical adjuvant.« less

  13. Low incidence of new biochemical hypogonadism after intensity modulated radiation therapy for prostate cancer.

    PubMed

    Markovina, Stephanie; Weschenfelder, Débora Cristina; Gay, Hiram; McCandless, Audrey; Carey, Bethany; DeWees, Todd; Knutson, Nels; Michalski, Jeff

    2014-01-01

    To evaluate serum testosterone and the incidence of biochemical hypogonadism in men treated with intensity modulated radiation therapy (IMRT) for prostate cancer. Serum testosterone was evaluated prospectively in 51 men at pretreatment and at 6-month time points for 2 years posttreatment with IMRT for prostate cancer. Forty-one patients (80%) were treated with definitive intent and 10 patients with postprostatectomy radiation to median total doses of 7380 cGy and 6480 cGy, respectively. No patients received hormone therapy within 12 months of any serum testosterone value. Biochemical hypogonadism was defined as a total serum testosterone level ≤ 300 ng/dL. Incidental testicular dose was calculated using planning software when computed tomography information was available (n = 21) and using a published method of estimation when not available (n = 24), and was available for 45 patients. A statistically significant decrease in testosterone, though small in magnitude, was seen at 6 months after completion of therapy, with no significant difference by 1 year after completion of therapy. There was no increase in biochemical hypogonadism after IMRT. Below-normal pretreatment testosterone was not associated with a transient decrease. Estimated cumulative testicular dose, including dose from daily imaging, was not associated with a change in testosterone, nor was radiation therapy prescription dose or treatment intent (postoperative vs definitive). The mild transient decrease in serum testosterone following IMRT monotherapy for prostate cancer is not associated with new biochemical hypogonadism.

  14. Reduction of radiation dose during facet joint injection using the new image guidance system SabreSource™: a prospective study in 60 patients

    PubMed Central

    Proschek, Dirk; Kafchitsas, K.; Rauschmann, M. A.; Kurth, A. A.; Vogl, T. J.

    2008-01-01

    Interventional procedures are associated with high radiation doses for both patients and surgeons. To reduce the risk from ionizing radiation, it is essential to minimize radiation dose. This prospective study was performed to evaluate the effectiveness in reducing radiation dose during facet joint injection in the lumbar spine and to evaluate the feasibility and possibilities of the new real time image guidance system SabreSource™. A total of 60 patients, treated with a standardized injection therapy of the facet joints L4–L5 or L5–S1, were included in this study. A total of 30 patients were treated by fluoroscopy guidance alone, the following 30 patients were treated using the new SabreSource™ system. Thus a total of 120 injections to the facet joints were performed. Pain, according to the visual analogue scale (VAS), was documented before and 6 h after the intervention. Radiation dose, time of radiation and the number of exposures needed to place the needle were recorded. No significant differences concerning age (mean age 60.5 years, range 51–69), body mass index (mean BMI 26.2, range 22.2–29.9) and preoperative pain (VAS 7.9, range 6–10) were found between the two groups. There was no difference in pain reduction between the two groups (60 vs. 61.5%; P = 0.001) but the radiation dose was significantly smaller with the new SabreSource™ system (reduction of radiation dose 32.7%, P = 0.01; reduction of mean entrance surface dose 32.3%, P = 0.01). The SabreSource™ System significantly reduced the radiation dose received during the injection therapy of the lumbar facet joints. With minimal effort for the setup at the beginning of a session, the system is easy to handle and can be helpful for other injection therapies (e.g. nerve root block therapies). PMID:19082641

  15. The Impact of Dose Rate on the Accuracy of Step-and-Shoot Intensity-modulated Radiation Therapy Quality Assurance Using Varian 2300CD.

    PubMed

    Njeh, Christopher F; Salmon, Howard W; Schiller, Claire

    2017-01-01

    Intensity-modulated radiation therapy (IMRT) delivery using "step-and-shoot" technique on Varian C-Series linear accelerator (linac) is influenced by the communication frequency between the multileaf collimator and linac controllers. Hence, the dose delivery accuracy is affected by the dose rate. Our aim was to quantify the impact of using two dose rates on plan quality assurance (QA). Twenty IMRT patients were selected for this study. The plan QA was measured at two different dose rates. A gamma analysis was performed, and the degree of plan modulation on the QA pass rate was also evaluated in terms of average monitor unit per segment (MU/segment) and the total number of segments. The mean percentage gamma pass rate of 94.9% and 93.5% for 300 MU/min and 600 MU/min dose rate, respectively, was observed. There was a significant ( P = 0.001) decrease in percentage gamma pass rate when the dose rate was increased from 300 MU/min to 600 MU/min. There was a weak, but significant association between the percentage pass rate at both dose rate and total number of segments. The total number of MU was significantly correlated to the total number of segments ( r = 0.59). We found a positive correlation between the percentage pass rate and mean MU/segment, r = 0.52 and r = 0.57 for 300 MU/min and 600 MU/min, respectively. IMRT delivery using step-and-shoot technique on Varian 2300CD is impacted by the dose rate and the total amount of segments.

  16. Stage III and oestrogen receptor negativity are associated with poor prognosis after adjuvant high-dose therapy in high-risk breast cancer

    PubMed Central

    Hohaus, S; Funk, L; Martin, S; Schlenk, R F; Abdallah, A; Hahn, U; Egerer, G; Goldschmidt, H; Schneeweiß, A; Fersis, N; Kaul, S; Wallwiener, D; Bastert, G; Haas, R

    1999-01-01

    We report on the efficacy and toxicity of a sequential high-dose therapy with peripheral blood stem cell (PBSC) support in 85 patients with high-risk stage II/III breast cancer. There were 71 patients with more than nine tumour-positive axillary lymph nodes. An induction therapy of two cycles of ifosfamide (total dose, 7.5 g m−2) and epirubicin (120 mg m−2) was given, and PBSC were harvested during G-CSF-supported leucocyte recovery following the second cycle. The PBSC-supported high-dose chemotherapy consisted of two cycles of ifosfamide (total dose, 12 000 mg m−2), carboplatin (900 mg m−2) and epirubicin (180 mg m−2). Patients were autografted with a median number of 3.7 × 106 CD34+ cells kg−1 (range, 1.9–26.5 × 106) resulting in haematological reconstitution within approximately 2 weeks following high-dose therapy. The toxicity was moderate in general, and there was no treatment-related toxic death. Twenty-one patients relapsed between 3 and 30 months following the last cycle of high-dose therapy (median, 11 months). The probability of disease-free and overall survival at 4 years were 60% and 83%, respectively. According to a multivariate analysis, patients with stage II disease had a significantly better probability of disease-free survival (74%) in comparison to patients with stage III disease (36%). The probability of disease-free survival was also significantly better for patients with oestrogen receptor-positive tumours (70%) compared to patients with receptor-negative ones (40%). Bone marrow samples collected from 52 patients after high-dose therapy were examined to evaluate the prognostic relevance of isolated tumour cells. The proportion of patients presenting with tumour cell-positive samples did not change in comparison to that observed before high-dose therapy (65% vs 71%), but a decrease in the incidence and concentration of tumour cells was observed over time after high-dose therapy. This finding was true for patients with relapse and for those in remission, which argues against a prognostic significance of isolated tumour cells in bone marrow. In conclusion, sequential high-dose chemotherapy with PBSC support can be safely administered to patients with high-risk stage II/III breast cancer. Further intensification of the therapy, including the addition of non-cross resistant drugs or immunological approaches such as the use of antibodies against HER-2/NEU, may be envisaged for patients with stage III disease and hormone receptor-negative tumours. © 1999 Cancer Research Campaign PMID:10188897

  17. Is Parenteral Levothyroxine Therapy Safe in Intractable Hypothyroidism?

    PubMed

    Peynirci, Hande; Taskiran, Bengur; Erturk, Erdinc; Sisman, Pınar; Ersoy, Canan

    2018-06-01

    A 32-year old woman was admitted to the hospital due to intractable hypothyroidism refractory to high dose of oral l-thyroxine therapy. She underwent total thyroidectomy and radioactive iodine therapy due to papillary thyroid cancer. After excluding poor adherence to therapy and malabsorption, levothyroxine absorption test was performed. No response was detected. Transient neurologic symptoms developed during the test. She developed 3 attacks consisting of neurologic symptoms during high dose administration. The patient was considered a case of isolated l-thyroxine malabsorption. She became euthyroid after intramuscular twice weekly l-thyroxine therapy. There are a few case reports regarding isolated l-thyroxine. We report successful long term results of twice weekly administered intramuscular l-thyroxine therapy. We also draw attention to neurologic side effects of high dose l-thyroxine therapy. Copyright © 2017 National Medical Association. Published by Elsevier Inc. All rights reserved.

  18. Total Skin Electron Beam for Primary Cutaneous T-cell Lymphoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elsayad, Khaled; Kriz, Jan; Moustakis, Christos

    Purpose: Recent trials with low-dose total skin electron beam (TSEB) therapy demonstrated encouraging results for treating primary cutaneous T-cell lymphoma (PCTCL). In this study, we assessed the feasibility of different radiation doses and estimated survival rates of different pathologic entities and stages. Methods and Materials: We retrospectively identified 45 patients with PCTCL undergoing TSEB therapy between 2000 and 2015. Clinical characteristics, treatment outcomes, and toxicity were assessed. Results: A total of 49 courses of TSEB therapy were administered to the 45 patients. There were 26 pathologically confirmed cases of mycosis fungoides (MF) lymphoma, 10 cases of Sézary syndrome (SS), andmore » 9 non-MF/SS PCTCL patients. In the MF patients, the overall response rate (ORR) was 92% (50% complete remission [CR]), 70% ORR in SS patients (50% CR), and 89% ORR in non-MF/SS patients (78% CR). The ORR for MF/SS patients treated with conventional dose (30-36 Gy) regimens was 92% (63% CR) and 75% (25% CR) for low-dose (<30-Gy) regimens (P=.09). In MF patients, the overall survival (OS) was 77 months with conventional dose regimens versus 14 months with low-dose regimens (P=.553). In SS patients, the median OS was 48 versus 16 months (P=.219), respectively. Median event-free survival (EFS) for MF in conventional dose patients versus low-dose patients was 15 versus 8 months, respectively (P=.264) and 19 versus 3 months for SS patients (P=.457). Low-dose regimens had shorter treatment time (P=.009) and lower grade 2 adverse events (P=.043). A second TSEB course was administered in 4 MF patients with 100% ORR. There is a possible prognostic impact of supplemental/boost radiation (P<.001); adjuvant treatment (P<.001) and radiation tolerability (P=.021) were detected. Conclusions: TSEB therapy is an efficacious treatment modality in the treatment of several forms of cutaneous T-cell lymphoma. There is a nonsignificant trend to higher and longer clinical benefit for MF and SS patients receiving conventional dose. Low-dose TSEB regimens are well tolerated and achieve short-term palliation.« less

  19. Linac-based total body irradiation (TBI) with volumetric modulated arc therapy (VMAT)

    NASA Astrophysics Data System (ADS)

    Tas, B.; Durmus, I. F.; Okumus, A.; Uzel, O. E.

    2017-02-01

    To evaluate dose distribution of Volumetric modulated arc therapy (VMAT) planning tecnique using Versa HD® lineer accelerator to deliver Total Body Irradiation (TBI) on the coach. Eight TBI patient's Treatment Planning System (TPS) were performed with dual arc VMAT for each patient. The VMAT-TBI consisted of three isocentres and three dual overlapping arcs. The prescribed dose was 12 Gy. Mean dose to lung and kidney were restricted less than 10 Gy and max. dose to lens were restricted less than 6 Gy. The plans were verified using 2D array and ion chamber. The comparison between calculation and measurement were made by γ-index analysis and absolute dose. An average total delivery time was determined 923±34 seconds and an average MU was determined 2614±228 MUs for dual arc VMAT. Mean dose to lungs was 9.7±0.2 Gy, mean dose to kidneys was 8.8±0.3 Gy, max. dose to lens was 5.5±0.3 Gy and max. dose was 14.6±0.3 Gy, HI of PTV was 1.13±0.2, mean dose to PTV was 12.6±1.5 Gy and mean γ-index pass rate was %97.1±1.9. The results show that the tecnique for TBI using VMAT on the treatment coach is feasible.

  20. Randomized, Multicenter Trial on the Effect of Radiation Therapy on Plantar Fasciitis (Painful Heel Spur) Comparing a Standard Dose With a Very Low Dose: Mature Results After 12 Months' Follow-Up

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Niewald, Marcus, E-mail: marcus.niewald@uks.eu; Seegenschmiedt, M. Heinrich; Micke, Oliver

    2012-11-15

    Purpose: To conduct a randomized trial of radiation therapy for painful heel spur, comparing a standard dose with a very low dose. Methods and Materials: Sixty-six patients were randomized to receive radiation therapy either with a total dose of 6.0 Gy applied in 6 fractions of 1.0 Gy twice weekly (standard dose) or with a total dose of 0.6 Gy applied in 6 fractions of 0.1 Gy twice weekly (low dose). In all patients lateral opposing 4- to 6-MV photon beams were used. The results were measured using a visual analogue scale, the Calcaneodynia score, and the SF12 health survey.more » The fundamental phase of the study ended after 3 months, and the follow-up was continued up to 1 year. Patients with insufficient pain relief after 3 months were offered reirradiation with the standard dosage at any time afterward. Results: Of 66 patients, 4 were excluded because of withdrawal of consent or screening failures. After 3 months the results in the standard arm were highly significantly superior compared with those in the low-dose arm (visual analogue scale, P=.001; Calcaneodynia score, P=.027; SF12, P=.045). The accrual of patients was stopped at this point. Further evaluation after 12 months' follow-up showed the following results: (1) highly significant fewer patients were reirradiated in the standard arm compared with the low-dose arm (P<.001); (2) the results of patients in the low-dose arm who were reirradiated were identical to those in the standard arm not reirradiated (reirradiation as a salvage therapy if the lower dose was ineffective); (3) patients experiencing a favorable result after 3 months showed this even after 12 months, and some results even improved further between 3 and 12 months. Conclusions: This study confirms the superior analgesic effect of radiation therapy with 6-Gy doses on painful heel spur even for a longer time period of at least 1 year.« less

  1. Diuretic downsides--but in low doses they still seem among the best authenticated antihypertensives.

    PubMed

    Opie, L H

    2000-08-01

    Diuretics in low doses have the greatest support among current available antihypertensives in that they have been shown to reduce total mortality, coronary mortality, stroke, and congestive heart failure in an important meta-analysis by Psaty. Recently, Messerli has linked longterm diuretic use to renal cell carcinoma in women. In some patients, diuretic use leads to increasing blood cholesterol and blood sugar levels. Impotence is a recognized side effect, with rates rising about twofold with low-dose chlorthalidone and fourfold with a higher dose. Certain population groups such as younger (<60 years) white males often do not respond to low-dose diuretic therapy with an adequate blood pressure fall. In females of a similar age group, Messerli calculates that prolonged diuretic therapy will prevent only one stroke and no coronary events nor any deaths for every renal cell carcinoma that is provoked. Despite these evident problems, the outcome data on hard endpoints in trials with initial low-dose diuretic therapy remain valid and convincing. Thus, it is argued, low- but not high-dose diuretics retain their primacy in the ranking of antihypertensive therapy.

  2. Exploring Radiotherapy Targeting Strategy and Dose: A Pooled Analysis of Cooperative Group Trials of Combined Modality Therapy for Stage III Non-Small Cell Lung Cancer.

    PubMed

    Schild, Steven E; Fan, Wen; Stinchcombe, Thomas E; Vokes, Everett E; Ramalingam, Suresh S; Bradley, Jeffrey D; Kelly, Karen; Pang, Herbert H; Wang, Xiaofei

    2018-04-21

    Concurrent chemoradiotherapy(CRT) is standard therapy for locally-advanced non-small-cell lung cancer(LA-NSCLC)patients. This study was performed to examine thoracic radiotherapy(TRT) parameters and their impact on patient survival. We collected Individual patient data(IPD) from 3600LA-NSCLC patients participating in 16 cooperative group trials of concurrent CRT. The primary TRT parameters examined included field design strategy(elective nodal irradiation(ENI) compared to involved field TRT(IF-TRT)), total dose, and biologically effective dose(BED). Hazard ratios(HRs) for overall survival were calculated with univariable and multivariable Cox models. TRT doses ranged from 60 to 74 Gy with most treatments administered once-daily. ENI was associated with poorer survival than IF-TRT(univariable HR,1.37;95%CI,1.24-1.51,p<0.0001;multivariable HR,1.31;95%CI,1.08-1.59,p=0.002). The median survival of the IF and ENI patients were 24 and 16 months, respectively. Patients were divided into 3 dose groups: low total dose(60 Gy), medium total dose(>60Gy-66Gy) and high total dose(>66Gy-74 Gy). With reference to the low dose group, the multivariable HR's were 1.08 for the medium dose group(95%CI=0.93-1.25) and 1.12 for the high dose group(CI=0.97-1.30).The univariate p=0.054 and multivariable p=0.17. BED was grouped as follows: low(<55.5Gy 10 ), medium(=55.5 Gy 10) , or high(>55.5 Gy 10 ). With reference to the low BED group, the HR was 1.00(95%CI=0.85-1.18) for the medium BED group and 1.10(95%CI=0.93-1.31) for the high BED group. The univariable p=0.076 and multivariable p=0.16. For LA-NSCLC patients treated with concurrent CRT, IF-TRT was associated with significantly better survival than ENI-TRT. TRT total and BED dose levels were not significantly associated with patient survival. Future progress will require research focusing on better systemic therapy and TRT. Copyright © 2018. Published by Elsevier Inc.

  3. Prediction model of critical weight loss in cancer patients during particle therapy.

    PubMed

    Zhang, Zhihong; Zhu, Yu; Zhang, Lijuan; Wang, Ziying; Wan, Hongwei

    2018-01-01

    The objective of this study is to investigate the predictors of critical weight loss in cancer patients receiving particle therapy, and build a prediction model based on its predictive factors. Patients receiving particle therapy were enroled between June 2015 and June 2016. Body weight was measured at the start and end of particle therapy. Association between critical weight loss (defined as >5%) during particle therapy and patients' demographic, clinical characteristic, pre-therapeutic nutrition risk screening (NRS 2002) and BMI were evaluated by logistic regression and decision tree analysis. Finally, 375 cancer patients receiving particle therapy were included. Mean weight loss was 0.55 kg, and 11.5% of patients experienced critical weight loss during particle therapy. The main predictors of critical weight loss during particle therapy were head and neck tumour location, total radiation dose ≥70 Gy on the primary tumour, and without post-surgery, as indicated by both logistic regression and decision tree analysis. Prediction model that includes tumour locations, total radiation dose and post-surgery had a good predictive ability, with the area under receiver operating characteristic curve 0.79 (95% CI: 0.71-0.88) and 0.78 (95% CI: 0.69-0.86) for decision tree and logistic regression model, respectively. Cancer patients with head and neck tumour location, total radiation dose ≥70 Gy and without post-surgery were at higher risk of critical weight loss during particle therapy, and early intensive nutrition counselling or intervention should be target at this population. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. The predictive factors of α1-D/A adrenoceptor antagonist, naftopidil, dose increase therapy for male lower urinary tract symptoms caused by benign prostatic hyperplasia: INFORM study.

    PubMed

    Tanuma, Yasushi; Tanaka, Yoshinori; Takeyama, Ko; Okamoto, Tomoshi

    2017-01-01

    We evaluated the predictive factors which affect the efficacy of naftopidil 50 mg/day therapy and dose increase therapy to administration of 75 mg/day after an initial dose of 50 mg/day. A total of 92 patients with male lower urinary tract symptoms/benign prostatic hyperplasia were administrated naftopidil 50 mg/day for 4 weeks (50 mg therapy). At week 4, the patients were divided into an effective and an ineffective group (Group E and Group I, respectively). For further 4 weeks, the dosage of naftopidil was increased to 75 mg/day in all patients. At week 8, the patients of Group E and Group I were divided into an effective and an ineffective group (Group EE, Group EI, Group IE, and Group II, respectively). Postvoid residual (PVR) urine volume at baseline was a predictive factor for efficacy of 50 mg therapy. In Group E, change in International Prostate Symptom Score storage symptoms subscore from baseline to week 4 was a predictive factor for efficacy of this dose increase therapy. In Group I, change in maximum flow rate from baseline to week 4 was a predictive factor for efficacy of this dose increase therapy. The short term of naftopidil 50 mg therapy was ineffective for the patients who had large PVR. The predictive factor of this dose increase therapy might be a dynamic variable in 50 mg/day of dose period, but not a baseline variable at the time of 75 mg/day dosage starts.

  5. Glioblastoma in Children: A Single-Institution Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perkins, Stephanie M.; Rubin, Joshua B.; Leonard, Jeffrey R.

    2011-07-15

    Purpose: Current treatment recommendations for pediatric glioblastoma include surgery, chemotherapy, and radiation therapy. However, even with this multispecialty approach, overall survival remains poor. To assess outcome and evaluate treatment-related prognostic factors, we retrospectively reviewed the experience at our institution. Methods and Materials: Twenty-four glioblastoma patients under the age of 21 were treated with radiation therapy with curative intent at Washington University, St. Louis, from 1970 to 2008. Patients underwent gross total resection, subtotal resection or biopsy alone. Fourteen (58%) of the patients received chemotherapy. All patients received radiation therapy. Radiation consisted of whole-brain radiation therapy in 7 (29%) patients withmore » a median dose of 50.4 Gy. Seventeen (71%) patients received three-dimensional conformal radiation therapy with a median dose of 54 Gy. Results: Median follow-up was 12.5 months from diagnosis. One and 2-year overall survival rates were 57% and 32%, respectively. Median overall survival was 13.5 months. There were no differences in overall survival based on patients' age, race, gender, tumor location, radiation volume, radiation dose, or the use of chemotherapy. There was a significant improvement in overall survival for patients in whom gross total resection was achieved (p = 0.023). Three patients were alive 5 years after gross total resection, and 2 patients were alive at 10 and 24 years after diagnosis. Conclusions: Survival for children with glioblastoma remains poor. Data from this and other studies demonstrate the importance of achieving a gross total resection. Continued investigation into new treatment options is needed in an attempt to improve outcome for these patients.« less

  6. High-dose methotrexate and rituximab with deferred radiotherapy for newly diagnosed primary B-cell CNS lymphoma.

    PubMed

    Chamberlain, Marc C; Johnston, Sandra K

    2010-07-01

    We conducted a prospective Phase II study of high-dose methotrexate (HD-MTX) and rituximab with deferred whole brain radiotherapy in patients with newly diagnosed B-cell primary central nervous system lymphoma with a primary objective of evaluating progression-free survival (PFS). Forty patients (25 men; 15 women), ages 18-93 years (median 61.5), were treated. All patients received biweekly HD-MTX/rituximab (8 g/m(2)/dose; 375 mg/m(2)/dose) for 4-6 cycles (induction) and following best radiographic response, with every 4 weeks HD-MTX (8 g/m(2)/dose) for 4 cycles (maintenance). Neurological and neuroradiographic evaluation were performed every 4 weeks during induction therapy and every 8 weeks during maintenance therapy. All patients were evaluable. A total of 303 cycles of HD-MTX (median 8 cycles; range 4-10) was administered. HD-MTX/rituximab-related toxicity included 16 grade 3 adverse events in 13 patients (32.5%). Following induction, 8 patients (20%) demonstrated progressive disease and discontinued therapy; 32 patients (80%) demonstrated a partial (8/40; 20%) or complete (24/40; 60%) radiographic response. At the conclusion of maintenance therapy (6-10 months of total therapy), 28 patients (70%) demonstrated either a partial (1/28) or complete (27/28) response. Overall, survival of these 28 patients ranged from 11 to 80 months (median 33.5). Survival in the entire cohort ranged from 6 to 80 months with an estimated median of 29 months. Overall, PFS ranged from 2 to 80 months (median 21.0). HD-MTX/rituximab and deferred radiotherapy demonstrated similar or better efficacy similar to other HD-MTX-only regimens and reduced time on therapy on average to 6 months.

  7. High-dose methotrexate and rituximab with deferred radiotherapy for newly diagnosed primary B-cell CNS lymphoma

    PubMed Central

    Chamberlain, Marc C.; Johnston, Sandra K.

    2010-01-01

    We conducted a prospective Phase II study of high-dose methotrexate (HD-MTX) and rituximab with deferred whole brain radiotherapy in patients with newly diagnosed B-cell primary central nervous system lymphoma with a primary objective of evaluating progression-free survival (PFS). Forty patients (25 men; 15 women), ages 18–93 years (median 61.5), were treated. All patients received biweekly HD-MTX/rituximab (8 g/m2/dose; 375 mg/m2/dose) for 4–6 cycles (induction) and following best radiographic response, with every 4 weeks HD-MTX (8 g/m2/dose) for 4 cycles (maintenance). Neurological and neuroradiographic evaluation were performed every 4 weeks during induction therapy and every 8 weeks during maintenance therapy. All patients were evaluable. A total of 303 cycles of HD-MTX (median 8 cycles; range 4–10) was administered. HD-MTX/rituximab-related toxicity included 16 grade 3 adverse events in 13 patients (32.5%). Following induction, 8 patients (20%) demonstrated progressive disease and discontinued therapy; 32 patients (80%) demonstrated a partial (8/40; 20%) or complete (24/40; 60%) radiographic response. At the conclusion of maintenance therapy (6–10 months of total therapy), 28 patients (70%) demonstrated either a partial (1/28) or complete (27/28) response. Overall, survival of these 28 patients ranged from 11 to 80 months (median 33.5). Survival in the entire cohort ranged from 6 to 80 months with an estimated median of 29 months. Overall, PFS ranged from 2 to 80 months (median 21.0). HD-MTX/rituximab and deferred radiotherapy demonstrated similar or better efficacy similar to other HD-MTX-only regimens and reduced time on therapy on average to 6 months. PMID:20511181

  8. Motexafin-Gadolinium and Involved Field Radiation Therapy for Intrinsic Pontine Glioma of Childhood: A Children's Oncology Group Phase 2 Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bradley, Kristin A., E-mail: bradley@humonc.wisc.edu; Zhou Tianni; McNall-Knapp, Rene Y.

    2013-01-01

    Purpose: To evaluate the effects on 1-year event-free survival (EFS) and overall survival (OS) of combining motexafin and gadolinium (MGd), a potent radiosensitizer, with daily fractionated radiation therapy in children with newly diagnosed intrinsic pontine gliomas. Methods and Materials: Patients with newly diagnosed intrinsic pontine glioma were treated with MGd daily for 5 consecutive days each week, for a total of 30 doses. Patients received a 5- to 10-min intravenous bolus of MGd, 4.4 mg/kg/day, given 2 to 5 h prior to standard dose irradiation. Radiation therapy was administered at a daily dose of 1.8 Gy for 30 treatments overmore » 6 weeks. The total dose was 54 Gy. Results: Sixty eligible children received MGd daily, concurrent with 6 weeks of radiation therapy. The estimated 1-year EFS was 18% {+-} 5%, and the estimated 1-year OS was 53% {+-} 6.5%. The most common grade 3 to 4 toxicities were lymphopenia, transient elevation of liver transaminases, and hypertension. Conclusions: Compared to historical controls, the addition of MGd to a standard 6-week course of radiation did not improve the survival of pediatric patients with newly diagnosed intrinsic pontine gliomas.« less

  9. Beyond Gaussians: a study of single spot modeling for scanning proton dose calculation

    PubMed Central

    Li, Yupeng; Zhu, Ronald X.; Sahoo, Narayan; Anand, Aman; Zhang, Xiaodong

    2013-01-01

    Active spot scanning proton therapy is becoming increasingly adopted by proton therapy centers worldwide. Unlike passive-scattering proton therapy, active spot scanning proton therapy, especially intensity-modulated proton therapy, requires proper modeling of each scanning spot to ensure accurate computation of the total dose distribution contributed from a large number of spots. During commissioning of the spot scanning gantry at the Proton Therapy Center in Houston, it was observed that the long-range scattering protons in a medium may have been inadequately modeled for high-energy beams by a commercial treatment planning system, which could lead to incorrect prediction of field-size effects on dose output. In the present study, we developed a pencil-beam algorithm for scanning-proton dose calculation by focusing on properly modeling individual scanning spots. All modeling parameters required by the pencil-beam algorithm can be generated based solely on a few sets of measured data. We demonstrated that low-dose halos in single-spot profiles in the medium could be adequately modeled with the addition of a modified Cauchy-Lorentz distribution function to a double-Gaussian function. The field-size effects were accurately computed at all depths and field sizes for all energies, and good dose accuracy was also achieved for patient dose verification. The implementation of the proposed pencil beam algorithm also enabled us to study the importance of different modeling components and parameters at various beam energies. The results of this study may be helpful in improving dose calculation accuracy and simplifying beam commissioning and treatment planning processes for spot scanning proton therapy. PMID:22297324

  10. Brain dose-sparing radiotherapy techniques for localized intracranial germinoma: Case report and literature review of modern irradiation.

    PubMed

    Leung, H W C; Chan, A L F; Chang, M B

    2016-05-01

    We examined the effects of intensity-modulated radiation therapy with dose-sparing and avoidance technique on a pediatric patient with localized intracranial germinoma. We also reviewed the literature regarding modern irradiation techniques in relation to late neurocognitive sequelae. A patient with a localized intracranial germinoma in the third ventricle anterior to the pineal gland received a dose-sparing intensity-modulated radiation therapy. The planning was compared to the radiation oncologist's guide of organs at risk and dose constraints for dosimetric analyses. The patient received radiation therapy alone. The total dose was 54Gy delivered in 2.0Gy fractions to the primary tumour and 37Gy in 1.4Gy fractions to whole ventricles using a dose-sculpting plan. Dosimetry analyses showed that dose-sparing intensity-modulated radiation therapy delivered reduced doses to the whole brain, temporal lobes, hippocampi, cochleae, and optic nerves. With a follow-up of 22 months, failure-free survival was 100% for the patient and no adverse events during radiation treatment process. Intensity-modulated radiation therapy with dose sparing and avoidance technique can spare the limbic circuit, central nervous system, and hippocampus for pineal germ cell tumours. This technique reduces the integral dose delivered to the uninvolved normal brain tissues and may reduce late neurocognitive sequelae caused by cranial radiotherapy. Copyright © 2016 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  11. Comparison of risk of radiogenic second cancer following photon and proton craniospinal irradiation for a pediatric medulloblastoma patient

    NASA Astrophysics Data System (ADS)

    Zhang, Rui; Howell, Rebecca M.; Giebeler, Annelise; Taddei, Phillip J.; Mahajan, Anita; Newhauser, Wayne D.

    2013-02-01

    Pediatric patients who received radiation therapy are at risk of developing side effects such as radiogenic second cancer. We compared proton and photon therapies in terms of the predicted risk of second cancers for a 4 year old medulloblastoma patient receiving craniospinal irradiation (CSI). Two CSI treatment plans with 23.4 Gy or Gy (RBE) prescribed dose were computed: a three-field 6 MV photon therapy plan and a four-field proton therapy plan. The primary doses for both plans were determined using a commercial treatment planning system. Stray radiation doses for proton therapy were determined from Monte Carlo simulations, and stray radiation doses for photon therapy were determined from measured data. Dose-risk models based on the Biological Effects of Ionization Radiation VII report were used to estimate the risk of second cancer in eight tissues/organs. Baseline predictions of the relative risk for each organ were always less for proton CSI than for photon CSI at all attained ages. The total lifetime attributable risk of the incidence of second cancer considered after proton CSI was much lower than that after photon CSI, and the ratio of lifetime risk was 0.18. Uncertainty analysis revealed that the qualitative findings of this study were insensitive to any plausible changes of dose-risk models and mean radiation weighting factor for neutrons. Proton therapy confers lower predicted risk of second cancer than photon therapy for the pediatric medulloblastoma patient.

  12. Dosimetric effect of beam arrangement for intensity-modulated radiation therapy in the treatment of upper thoracic esophageal carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fu, Yuchuan; Deng, Min; Zhou, Xiaojuan

    To evaluate the lung sparing in intensity-modulated radiation therapy (IMRT) for patients with upper thoracic esophageal tumors extending inferiorly to the thorax by different beam arrangement. Overall, 15 patient cases with cancer of upper thoracic esophagus were selected for a retrospective treatment-planning study. Intensity-modulated radiation therapy plans using 4, 5, and 7 beams (4B, 5B, and 7B) were developed for each patient by direct machine parameter optimization (DMPO). All plans were evaluated with respect to dose volumes to irradiated targets and normal structures, with statistical comparisons made between 4B with 5B and 7B intensity-modulated radiation therapy plans. Differences among plansmore » were evaluated using a two-tailed Friedman test at a statistical significance of p < 0.05. The maximum dose, average dose, and the conformity index (CI) of planning target volume 1 (PTV1) were similar for 3 plans for each case. No significant difference of coverage for planning target volume 1 and maximum dose for spinal cords were observed among 3 plans in present study (p > 0.05). The average V{sub 5}, V{sub 13}, V{sub 20}, mean lung dose, and generalized equivalent uniform dose (gEUD) for the total lung were significantly lower in 4B-plans than those data in 5B-plans and 7B-plans (p < 0.01). Although the average V{sub 30} for the total lung were significantly higher in 4B-plans than those in 5B-plans and 7B-plans (p < 0.05). In addition, when comparing with the 4B-plans, the conformity/heterogeneity index of the 5B- and 7B-plans were significantly superior (p < 0.05). The 4B-intensity-modulated radiation therapy plan has advantage to address the specialized problem of lung sparing to low- and intermediate-dose exposure in the thorax when dealing with relative long tumors extended inferiorly to the thoracic esophagus for upper esophageal carcinoma with the cost for less conformity. Studies are needed to compare the superiority of volumetric modulated arc therapy with intensity-modulated radiation therapy technique.« less

  13. Low-dose (10-Gy) total skin electron beam therapy for cutaneous T-cell lymphoma: an open clinical study and pooled data analysis.

    PubMed

    Kamstrup, Maria R; Gniadecki, Robert; Iversen, Lars; Skov, Lone; Petersen, Peter Meidahl; Loft, Annika; Specht, Lena

    2015-05-01

    Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments is limited to 2 to 3 courses in a lifetime due to skin toxicity. This study aimed to determine the clinical effect of low-dose TSEBT in patients with MF and SS. In an open clinical study, 21 patients with MF/SS stages IB to IV were treated with low-dose TSEBT over <2.5 weeks, receiving a total dose of 10 Gy in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. The overall response rate was 95% with a complete cutaneous response or a very good partial response rate (<1% skin involvement with patches or plaques) documented in 57% of the patients. Median duration of overall cutaneous response was 174 days (5.8 months; range: 60-675 days). TSEBT-related acute adverse events (grade 1 or 2) were observed in 60% of patients. Low-dose (10-Gy) TSEBT offers a high overall response rate and is relatively safe. With this approach, reirradiation at times of relapse or progression is likely to be less toxic than standard dose TSEBT. It remains to be established whether adjuvant and combination treatments can prolong the beneficial effects of low-dose TSEBT. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Low-Dose (10-Gy) Total Skin Electron Beam Therapy for Cutaneous T-Cell Lymphoma: An Open Clinical Study and Pooled Data Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kamstrup, Maria R., E-mail: mkam0004@bbh.regionh.dk; Gniadecki, Robert; Iversen, Lars

    2015-05-01

    Purpose: Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments is limited to 2 to 3 courses in a lifetime due to skin toxicity. This study aimed to determine the clinical effect of low-dose TSEBT in patients with MF and SS. Methods and Materials: In an open clinical study, 21 patients with MF/SS stages IB to IV were treated with low-dose TSEBT over <2.5 weeks, receiving a total dose of 10 Gymore » in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. Results: The overall response rate was 95% with a complete cutaneous response or a very good partial response rate (<1% skin involvement with patches or plaques) documented in 57% of the patients. Median duration of overall cutaneous response was 174 days (5.8 months; range: 60-675 days). TSEBT-related acute adverse events (grade 1 or 2) were observed in 60% of patients. Conclusions: Low-dose (10-Gy) TSEBT offers a high overall response rate and is relatively safe. With this approach, reirradiation at times of relapse or progression is likely to be less toxic than standard dose TSEBT. It remains to be established whether adjuvant and combination treatments can prolong the beneficial effects of low-dose TSEBT.« less

  15. RADIATION THERAPY COMMUNICATION-REIRRADIATION OF A NASAL TUMOR IN A BRACHYCEPHALIC DOG USING INTENSITY MODULATED RADIATION THERAPY.

    PubMed

    Rancilio, Nicholas J; Custead, Michelle R; Poulson, Jean M

    2016-09-01

    A 5-year-old spayed female Shih Tzu was referred for evaluation of a nasal transitional carcinoma. A total lifetime dose of 117 Gy was delivered to the intranasal mass in three courses over nearly 2 years using fractionated intensity modulated radiation therapy (IMRT) to spare normal tissues. Clinically significant late normal tissue side effects were limited to bilaterally diminished tear production. The patient died of metastatic disease progression 694 days after completion of radiation therapy course 1. This case demonstrates that retreatment with radiation therapy to high lifetime doses for recurrent local disease may be well tolerated with IMRT. © 2016 American College of Veterinary Radiology.

  16. Spot-Scanning Proton Arc (SPArc) Therapy: The First Robust and Delivery-Efficient Spot-Scanning Proton Arc Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Xuanfeng, E-mail: Xuanfeng.ding@beaumont.org; Li, Xiaoqiang; Zhang, J. Michele

    Purpose: To present a novel robust and delivery-efficient spot-scanning proton arc (SPArc) therapy technique. Methods and Materials: A SPArc optimization algorithm was developed that integrates control point resampling, energy layer redistribution, energy layer filtration, and energy layer resampling. The feasibility of such a technique was evaluated using sample patients: 1 patient with locally advanced head and neck oropharyngeal cancer with bilateral lymph node coverage, and 1 with a nonmobile lung cancer. Plan quality, robustness, and total estimated delivery time were compared with the robust optimized multifield step-and-shoot arc plan without SPArc optimization (Arc{sub multi-field}) and the standard robust optimized intensity modulatedmore » proton therapy (IMPT) plan. Dose-volume histograms of target and organs at risk were analyzed, taking into account the setup and range uncertainties. Total delivery time was calculated on the basis of a 360° gantry room with 1 revolutions per minute gantry rotation speed, 2-millisecond spot switching time, 1-nA beam current, 0.01 minimum spot monitor unit, and energy layer switching time of 0.5 to 4 seconds. Results: The SPArc plan showed potential dosimetric advantages for both clinical sample cases. Compared with IMPT, SPArc delivered 8% and 14% less integral dose for oropharyngeal and lung cancer cases, respectively. Furthermore, evaluating the lung cancer plan compared with IMPT, it was evident that the maximum skin dose, the mean lung dose, and the maximum dose to ribs were reduced by 60%, 15%, and 35%, respectively, whereas the conformity index was improved from 7.6 (IMPT) to 4.0 (SPArc). The total treatment delivery time for lung and oropharyngeal cancer patients was reduced by 55% to 60% and 56% to 67%, respectively, when compared with Arc{sub multi-field} plans. Conclusion: The SPArc plan is the first robust and delivery-efficient proton spot-scanning arc therapy technique, which could potentially be implemented into routine clinical practice.« less

  17. Efficacy of rasagiline for the treatment of Parkinson's disease: an updated meta-analysis.

    PubMed

    Chang, Ying; Wang, Li-Bo; Li, Dan; Lei, Ke; Liu, Song-Yan

    2017-08-01

    Rasagiline is a second-generation potent selective inhibitor of monoamine oxidase-B. The aim of the study was to analyze the effectiveness of rasagiline in treatment of Parkinson's disease (PD), both as monotherapy and combination therapy. Medline, Cochrane, EMBASE, and Google Scholar databases were searched until 9 March 2016 using the keywords: Rasagiline, Azilect, Parkinson's disease. Randomized controlled trials of patients with PD who were randomized to treatment with rasagiline or placebo were included. Outcomes were unified Parkinson's disease rating scale (UPDRS) and the three subscales. Ten studies fulfilled the inclusion criteria and 2709 patients were evaluated. The overall analysis revealed a significant improvement in change of total UPDRS scores in 1 mg/day and 2 mg/day rasagiline groups compared to placebo. Significant improvement in Part I (Mentation) of UPDRS scores was observed in 1 mg/day, but not in 2 mg/day rasagiline treatment group. Part II (ADL) and Part III (Motor) subscales significantly improved with both doses of rasagiline. Both monotherapy and combination therapy significantly improved total UPDRS scores. Our results confirm the efficacy of rasagiline in PD. Further studies are required to establish the optimal dose of rasagiline, as well as to determine its effectiveness in different combination therapy protocols. KEY MESSAGES Rasagiline treatment was associated with significant improvement of UPDRS scores and the scores of the subscales. Both monotherapy and combination therapy significantly improved total UPDRS scores. Effect of rasagiline on total UPDRS scores was not dose-dependent.

  18. Efficacy of different therapy regimes of low-power laser in painful osteoarthritis of the knee: a double-blind and randomized-controlled trial.

    PubMed

    Gur, Ali; Cosut, Abdulkadir; Sarac, Aysegul Jale; Cevik, Remzi; Nas, Kemal; Uyar, Asur

    2003-01-01

    A prospective, double-blind, randomized, and controlled trial was conducted in patients with knee osteoarthritis (OA) to evaluate the efficacy of infrared low-power Gallium-Arsenide (Ga-As) laser therapy (LPLT) and compared two different laser therapy regimes. Ninety patients were randomly assigned to three treatment groups by one of the nontreating authors by drawing 1 of 90 envelopes labeled 'A' (Group I: actual LPLT consisted of 5 minutes, 3 J total dose + exercise; 30 patients), 'B' (Group II: actual LPLT consisted of 3 minutes, 2 J total dose + exercise; 30 patients), and 'C' (Group III: placebo laser group + exercise; 30 patients). All patients received a total of 10 treatments, and exercise therapy program was continued during study (14 weeks). Subjects, physician, and data analysts were unaware of the code for active or placebo laser until the data analysis was complete. All patients were evaluated with respect to pain, degree of active knee flexion, duration of morning stiffness, painless walking distance and duration, and the Western Ontario and Mc Master Universities Osteoarthritis Index (WOMAC) at week 0, 6, 10, and 14. Statistically significant improvements were indicated in respect to all parameters such as pain, function, and quality of life (QoL) measures in the post-therapy period compared to pre-therapy in both active laser groups (P < 0.01). Improvements in all parameters of the Group I and in parameters, such as pain and WOMAC of the Group II, were more statistically significant when compared with placebo laser group (P < 0.05). Our study demonstrated that applications of LPLT in different dose and duration have not affected results and both therapy regimes were a safe and effective method in treatment of knee OA. Copyright 2003 Wiley-Liss, Inc.

  19. Stereotactic body radiation therapy of early-stage non-small-cell lung carcinoma: Phase I study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGarry, Ronald C.; Papiez, Lech; Williams, Mark

    Purpose: A Phase I dose escalation study of stereotactic body radiation therapy to assess toxicity and local control rates for patients with medically inoperable Stage I lung cancer. Methods and Materials: All patients had non-small-cell lung carcinoma, Stage T1a or T1b N0, M0. Patients were immobilized in a stereotactic body frame and treated in escalating doses of radiotherapy beginning at 24 Gy total (3 x 8 Gy fractions) using 7-10 beams. Cohorts were dose escalated by 6.0 Gy total with appropriate observation periods. Results: The maximum tolerated dose was not achieved in the T1 stratum (maximum dose = 60 Gy),more » but within the T2 stratum, the maximum tolerated dose was realized at 72 Gy for tumors larger than 5 cm. Dose-limiting toxicity included predominantly bronchitis, pericardial effusion, hypoxia, and pneumonitis. Local failure occurred in 4/19 T1 and 6/28 T2 patients. Nine local failures occurred at doses {<=}16 Gy and only 1 at higher doses. Local failures occurred between 3 and 31 months from treatment. Within the T1 group, 5 patients had distant or regional recurrence as an isolated event, whereas 3 patients had both distant and regional recurrence. Within the T2 group, 2 patients had solitary regional recurrences, and the 4 patients who failed distantly also failed regionally. Conclusions: Stereotactic body radiation therapy seems to be a safe, effective means of treating early-stage lung cancer in medically inoperable patients. Excellent local control was achieved at higher dose cohorts with apparent dose-limiting toxicities in patients with larger tumors.« less

  20. Radiation-Induced Liver Injury in Three-Dimensional Conformal Radiation Therapy (3D-CRT) for Postoperative or Locoregional Recurrent Gastric Cancer: Risk Factors and Dose Limitations.

    PubMed

    Li, Guichao; Wang, Jiazhou; Hu, Weigang; Zhang, Zhen

    2015-01-01

    This study examined the status of radiation-induced liver injury in adjuvant or palliative gastric cancer radiation therapy (RT), identified risk factors of radiation-induced liver injury in gastric cancer RT, analysed the dose-volume effects of liver injury, and developed a liver dose limitation reference for gastric cancer RT. Data for 56 post-operative gastric cancer patients and 6 locoregional recurrent gastric cancer patients treated with three-dimensional conformal radiation therapy (3D-CRT) or intensity-modulated radiation therapy (IMRT) from Sep 2007 to Sep 2009 were analysed. Forty patients (65%) were administered concurrent chemotherapy. Pre- and post-radiation chemotherapy were given to 61 patients and 43 patients, respectively. The radiation dose was 45-50.4 Gy in 25-28 fractions. Clinical parameters, including gender, age, hepatic B virus status, concurrent chemotherapy, and the total number of chemotherapy cycles, were included in the analysis. Univariate analyses with a non-parametric rank test (Mann-Whitney test) and logistic regression test and a multivariate analysis using a logistic regression test were completed. We also analysed the correlation between RT and the changes in serum chemistry parameters [including total bilirubin, (TB), direct bilirubin (D-TB), alkaline phosphatase (ALP), alanine aminotransferase (ALT), aspartate aminotransferase (AST) and serum albumin (ALB)] after RT. The Child-Pugh grade progressed from grade A to grade B after radiotherapy in 10 patients. A total of 16 cases of classic radiation-induced liver disease (RILD) were observed, and 2 patients had both Child-Pugh grade progression and classic RILD. No cases of non-classic radiation liver injury occurred in the study population. Among the tested clinical parameters, the total number of chemotherapy cycles correlated with liver function injury. V35 and ALP levels were significant predictive factors for radiation liver injury. In 3D-CRT for gastric cancer patients, radiation-induced liver injury may occur and affect the overall treatment plan. The total number of chemotherapy cycles correlated with liver function injury, and V35 and ALP are significant predictive factors for radiation-induced liver injury. Our dose limitation reference for liver protection is feasible.

  1. Efficacy of Radiation Therapy for the Treatment of Sialocele in Dogs.

    PubMed

    Poirier, V J; Mayer-Stankeová, S; Buchholz, J; Vail, D M; Kaser Hotz, B

    2018-01-01

    Sialocele is a collection of saliva that has leaked from a damaged salivary gland or duct and is surrounded by granulation tissue. Surgery is the recognized first-line treatment. Recurrence rate after surgery is 5-14%. Salivary gland tissue is very sensitive to radiation therapy (RT). Radiation therapy will be useful for the treatment of sialocele. The aims were to characterize response rate and clinical course of dogs with sialocele treated with RT and to determine a starting dose for clinical use. Eleven dogs with sialocele. Retrospective study of response and outcome after RT. All dogs had cervical sialocele. Seven dogs (63.6%) were treated with 3 weekly fractions of 4 Gray (Gy); (total dose, 12 Gy). Three dogs (27.3%) received 4 fractions of 4 Gy (16 Gy) and 1 dog received 5 fractions of 4 Gy (20 Gy) on a Monday-Wednesday-Friday schedule. Six dogs (54%) achieved a complete response (CR), and 5 dogs (45%) achieved a partial response (PR). Three dogs had progression of their sialocele 2, 3, and 9 months after RT; all three had received 12 Gy initially and 2 received 2 additional fractions of 4 Gy (cumulative total dose, 20 Gy) and subsequently achieved remission for >2 years. Radiation therapy is useful for the treatment of recurrent sialocele refractory to surgical management and a minimum total dose of 16 or 20 Gy in 4 Gy fractions appears effective. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  2. Radial to femoral arterial blood pressure differences in septic shock patients receiving high-dose norepinephrine therapy.

    PubMed

    Kim, Won Young; Jun, Jong Hun; Huh, Jin Won; Hong, Sang Bum; Lim, Chae-Man; Koh, Younsuck

    2013-12-01

    The accuracy of arterial blood pressure (ABP) monitoring is crucial in treating septic shock patients. Clinically significant differences in central to peripheral ABP could develop into sepsis during vasopressor therapy. The aim of this study was to investigate the difference between radial (peripheral) and femoral (central) ABP in septic shock patients receiving high-dose norepinephrine (NE) therapy. This prospective observational study comparing simultaneous intra-arterial measurements of radial and femoral ABP was performed at a university-affiliated, tertiary referral center between October 2008 and March 2009. Patients with septic shock who needed continuous blood pressure monitoring and high-dose NE therapy 0.1 µg/kg per minute or greater to maintain mean arterial pressure (MAP) of 65 mmHg or greater were included. Statistical analysis was conducted using the Bland-Altman method for comparison of repeated measures. In total, 250 sets of systolic, mean, and diastolic femoral and radial ABP were recorded at baseline and after NE titration. Arterial blood pressure readings from the radial artery were underestimated compared with those from the femoral artery. Overall bias (mean difference between simultaneous measurements) between radial and femoral MAP was +4.9 mmHg; however, during high-dose NE therapy, the bias increased to +6.2 mmHg (95% limits of agreement: -6.0 to +18.3 mmHg). Clinically significant radial-femoral MAP differences (MAP ≥5 mmHg) occurred in up to 62.2% of patients with high-dose NE therapy. Radial artery pressure frequently underestimates central pressure in septic shock patients receiving high-dose NE therapy. Femoral arterial pressure monitoring may be more appropriate when high-dose NE therapy is administered.

  3. Dose-dense and less dose-intense Total Therapy 5 for gene expression profiling-defined high-risk multiple myeloma.

    PubMed

    Jethava, Y; Mitchell, A; Zangari, M; Waheed, S; Schinke, C; Thanendrarajan, S; Sawyer, J; Alapat, D; Tian, E; Stein, C; Khan, R; Heuck, C J; Petty, N; Avery, D; Steward, D; Smith, R; Bailey, C; Epstein, J; Yaccoby, S; Hoering, A; Crowley, J; Morgan, G; Barlogie, B; van Rhee, F

    2016-07-29

    Multiple myeloma (MM) is a heterogeneous disease with high-risk patients progressing rapidly despite treatment. Various definitions of high-risk MM are used and we reported that gene expression profile (GEP)-defined high risk was a major predictor of relapse. In spite of our best efforts, the majority of GEP70 high-risk patients relapse and we have noted higher relapse rates during drug-free intervals. This prompted us to explore the concept of less intense drug dosing with shorter intervals between courses with the aim of preventing inter-course relapse. Here we report the outcome of the Total Therapy 5 trial, where this concept was tested. This regimen effectively reduced early mortality and relapse but failed to improve progression-free survival and overall survival due to relapse early during maintenance.

  4. Assessing the Clinical Impact of Approximations in Analytical Dose Calculations for Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schuemann, Jan, E-mail: jschuemann@mgh.harvard.edu; Giantsoudi, Drosoula; Grassberger, Clemens

    2015-08-01

    Purpose: To assess the impact of approximations in current analytical dose calculation methods (ADCs) on tumor control probability (TCP) in proton therapy. Methods: Dose distributions planned with ADC were compared with delivered dose distributions as determined by Monte Carlo simulations. A total of 50 patients were investigated in this analysis with 10 patients per site for 5 treatment sites (head and neck, lung, breast, prostate, liver). Differences were evaluated using dosimetric indices based on a dose-volume histogram analysis, a γ-index analysis, and estimations of TCP. Results: We found that ADC overestimated the target doses on average by 1% to 2%more » for all patients considered. The mean dose, D95, D50, and D02 (the dose value covering 95%, 50% and 2% of the target volume, respectively) were predicted within 5% of the delivered dose. The γ-index passing rate for target volumes was above 96% for a 3%/3 mm criterion. Differences in TCP were up to 2%, 2.5%, 6%, 6.5%, and 11% for liver and breast, prostate, head and neck, and lung patients, respectively. Differences in normal tissue complication probabilities for bladder and anterior rectum of prostate patients were less than 3%. Conclusion: Our results indicate that current dose calculation algorithms lead to underdosage of the target by as much as 5%, resulting in differences in TCP of up to 11%. To ensure full target coverage, advanced dose calculation methods like Monte Carlo simulations may be necessary in proton therapy. Monte Carlo simulations may also be required to avoid biases resulting from systematic discrepancies in calculated dose distributions for clinical trials comparing proton therapy with conventional radiation therapy.« less

  5. Comparison of testicular dose delivered by intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in patients with prostate cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, Jeffrey M.; Handorf, Elizabeth A.; Price, Robert A.

    A small decrease in testosterone level has been documented after prostate irradiation, possibly owing to the incidental dose to the testes. Testicular doses from prostate external beam radiation plans with either intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) were calculated to investigate any difference. Testicles were contoured for 16 patients being treated for localized prostate cancer. For each patient, 2 plans were created: 1 with IMRT and 1 with VMAT. No specific attempt was made to reduce testicular dose. Minimum, maximum, and mean doses to the testicles were recorded for each plan. Of the 16 patients, 4 receivedmore » a total dose of 7800 cGy to the prostate alone, 7 received 8000 cGy to the prostate alone, and 5 received 8000 cGy to the prostate and pelvic lymph nodes. The mean (range) of testicular dose with an IMRT plan was 54.7 cGy (21.1 to 91.9) and 59.0 cGy (25.1 to 93.4) with a VMAT plan. In 12 cases, the mean VMAT dose was higher than the mean IMRT dose, with a mean difference of 4.3 cGy (p = 0.019). There was a small but statistically significant increase in mean testicular dose delivered by VMAT compared with IMRT. Despite this, it unlikely that there is a clinically meaningful difference in testicular doses from either modality.« less

  6. Carcinoma of the vagina. [Complications following whole-pelvis. gamma. irradiation and radium implant therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marcus, R.B. Jr.; Million, R.R.; Daly, J.W.

    1978-11-01

    Twenty-two patients with Stage I through IV primary vaginal squamous cell carcinomas treated for cure with radiation therapy are reviewed, with particular emphasis on the relationship of dose to complications and local control. All but 2 patients received 4000 to 6000 rad whole pelvis irradiation plus at least one radium application. Local control was 91%, with an absolute 2-year disease-free survival of 82%. The degree of anaplasia was found to influence prognosis, with all local and distant failures resulting from high-grade lesions. The complication rate was modest, with no fistulae or serious bowel complications. An analysis of total dose (externalmore » plus radium) with respect to local failure and complications showed that no major complications occurred at a combined dose below 9000 rad. An analysis of the individual contributions of external irradiation and radium implants showed that all but one very minor complication occurred at a radium dose of 4000 rad or higher. From these data, overall treatment planning and total dose recommendations are made.« less

  7. Prospective Study Delivering Simultaneous Integrated High-dose Tumor Boost (≤70 Gy) With Image Guided Adaptive Radiation Therapy for Radical Treatment of Localized Muscle-Invasive Bladder Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hafeez, Shaista, E-mail: Shaista.Hafeez@icr.ac.uk; The Royal Marsden National Health Service Foundation Trust, London; Warren-Oseni, Karole

    Purpose: Image guided adaptive radiation therapy offers individualized solutions to improve target coverage and reduce normal tissue irradiation, allowing the opportunity to increase the radiation tumor dose and spare normal bladder tissue. Methods and Materials: A library of 3 intensity modulated radiation therapy plans were created (small, medium, and large) from planning computed tomography (CT) scans performed at 30 and 60 minutes; treating the whole bladder to 52 Gy and the tumor to 70 Gy in 32 fractions. A “plan of the day” approach was used for treatment delivery. A post-treatment cone beam CT (CBCT) scan was acquired weekly to assess intrafraction fillingmore » and coverage. Results: A total of 18 patients completed treatment to 70 Gy. The plan and treatment for 1 patient was to 68 Gy. Also, 1 patient's plan was to 70 Gy but the patient was treated to a total dose of 65.6 Gy because dose-limiting toxicity occurred before dose escalation. A total of 734 CBCT scans were evaluated. Small, medium, and large plans were used in 36%, 48%, and 16% of cases, respectively. The mean ± standard deviation rate of intrafraction filling at the start of treatment (ie, week 1) was 4.0 ± 4.8 mL/min (range 0.1-19.4) and at end of radiation therapy (ie, week 5 or 6) was 1.1 ± 1.6 mL/min (range 0.01-7.5; P=.002). The mean D{sub 98} (dose received by 98% volume) of the tumor boost and bladder as assessed on the post-treatment CBCT scan was 97.07% ± 2.10% (range 89.0%-104%) and 99.97% ± 2.62% (range 96.4%-112.0%). At a median follow-up period of 19 months (range 4-33), no muscle-invasive recurrences had developed. Two patients experienced late toxicity (both grade 3 cystitis) at 5.3 months (now resolved) and 18 months after radiation therapy. Conclusions: Image guided adaptive radiation therapy using intensity modulated radiation therapy to deliver a simultaneous integrated tumor boost to 70 Gy is feasible, with acceptable toxicity, and will be evaluated in a randomized trial.« less

  8. Radiation Therapy Dose Escalation for Glioblastoma Multiforme in the Era of Temozolomide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Badiyan, Shahed N.; Markovina, Stephanie; Simpson, Joseph R.

    Purpose: To review clinical outcomes of moderate dose escalation using high-dose radiation therapy (HDRT) in the setting of concurrent temozolomide (TMZ) in patients with newly diagnosed glioblastoma multiforme (GBM), compared with standard-dose radiation therapy (SDRT). Methods and Materials: Adult patients aged <70 years with biopsy-proven GBM were treated with SDRT (60 Gy at 2 Gy per fraction) or with HDRT (>60 Gy) and TMZ from 2000 to 2012. Biological equivalent dose at 2-Gy fractions was calculated for the HDRT assuming an α/β ratio of 5.6 for GBM. Results: Eighty-one patients received SDRT, and 128 patients received HDRT with a median (range) biological equivalent dosemore » at 2-Gy fractions of 64 Gy (61-76 Gy). Overall median follow-up time was 1.10 years, and for living patients it was 2.97 years. Actuarial 5-year overall survival (OS) and progression-free survival (PFS) rates for patients that received HDRT versus SDRT were 12.4% versus 13.2% (P=.71), and 5.6% versus 4.1% (P=.54), respectively. Age (P=.001) and gross total/near-total resection (GTR/NTR) (P=.001) were significantly associated with PFS on multivariate analysis. Younger age (P<.0001), GTR/NTR (P<.0001), and Karnofsky performance status ≥80 (P=.001) were associated with improved OS. On subset analyses, HDRT failed to improve PFS or OS for those aged <50 years or those who had GTR/NTR. Conclusion: Moderate radiation therapy dose escalation above 60 Gy with concurrent TMZ does not seem to improve clinical outcomes for patients with GBM.« less

  9. Abdominal Pediatric Cancer Surveillance using Serial CT: Evaluation of Organ Absorbed Dose and Effective Dose

    PubMed Central

    Lam, Diana; Wootton-Gorges, Sandra L.; McGahan, John P.; Stern, Robin; Boone, John M.

    2012-01-01

    Computed tomography (CT) is used extensively in cancer diagnosis, staging, evaluation of response to treatment, and in active surveillance for cancer reoccurrence. A review of CT technology is provided, at a level of detail appropriate for a busy clinician to review. The basis of x-ray CT dosimetry is also discussed, and concepts of absorbed dose and effective dose are distinguished. Absorbed dose is a physical quantity (measured in milliGray) equal to the x-ray energy deposited in a mass of tissue, whereas effective dose utilizes an organ-specific weighting method which converts organ doses to effective dose measured in milliSieverts. The organ weighting values carry with them a measure of radiation risk, and so effective dose (in mSv) is not a physical dose metric but rather is one that conveys radiation risk. The use of CT in a cancer surveillance protocol was used as an example of a pediatric patient who had kidney cancer, with surgery and radiation therapy. The active use of CT for cancer surveillance along with diagnostic CT scans led to a total of 50 CT scans performed on this child in a 7 year period. It was estimated that the patient received an average organ dose of 431 mGy from these CT scans. By comparison, the radiation therapy was performed and delivered 50.4 Gy to the patient’s abdomen. Thus, the total dose from CT represented only 0.8% of the patients radiation dose. PMID:21362521

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Islam, M; Ahmad, S; Jin, H

    Purpose: The out-of-beam dose is important for understanding the peripheral dose in radiation therapy. In proton radiotherapy, the study of out-of-beam dose is scarce and the treatment planning system (TPS) based on pencil beam algorithm cannot accurately predict the out-of-beam dose. This study investigates the out-of-beam dose for the single-room Mevion S250 double scattering proton therapy system using experimentally measured and treatment planning software generated data. The results are compared with those reported for conventional photon beam therapy. However, this study does not incorporate the neutron contribution in the scattered dose. Methods: A total of seven proton treatment plans weremore » generated using Varian Eclipse TPS for three different sites (brain, lung, and pelvis) in an anthropomorphic phantom. Three field sizes of 5×5, 10×10, and 20×20 cm{sup 2} (lung only) with typical clinical range (13.3–22.8 g/cm{sup 2}) and modulation widths (5.3–14.0 g/cm{sup 2}) were used. A single beam was employed in each treatment plan to deliver a dose of 181.8 cGy (200.0 cGy (RBE)) to the selected target. The out-of-beam dose was measured at 2.0, 5.0, 10.0, and 15.0 cm from the beam edge in the phantom using a thimble chamber (PTW TN31010). Results: The out-of-beam dose generally increased with field size, range, and volume irradiated. For all the plans, the scattered dose sharply fell off with distance. At 2.0 cm, the out-of-beam dose ranged from 0.35% to 2.16% of the delivered dose; however, the dose was clinically negligible (<0.3%) at a distance of 5.0 cm and greater. In photon therapy, the slightly greater out-of-beam dose was reported (TG36; 4%, 2%, and 1% for 2.0, 5.0, and 10.0 cm, respectively, using 6 MV beam). Conclusion: The measured out-of-beam dose in proton therapy excluding neutron contribution was observed higher than the TPS calculated dose and comparable to that of photon beam therapy.« less

  11. Dosimetric effect of beam arrangement for intensity-modulated radiation therapy in the treatment of upper thoracic esophageal carcinoma.

    PubMed

    Fu, Yuchuan; Deng, Min; Zhou, Xiaojuan; Lin, Qiang; Du, Bin; Tian, Xue; Xu, Yong; Wang, Jin; Lu, You; Gong, Youling

    2017-01-01

    To evaluate the lung sparing in intensity-modulated radiation therapy (IMRT) for patients with upper thoracic esophageal tumors extending inferiorly to the thorax by different beam arrangement. Overall, 15 patient cases with cancer of upper thoracic esophagus were selected for a retrospective treatment-planning study. Intensity-modulated radiation therapy plans using 4, 5, and 7 beams (4B, 5B, and 7B) were developed for each patient by direct machine parameter optimization (DMPO). All plans were evaluated with respect to dose volumes to irradiated targets and normal structures, with statistical comparisons made between 4B with 5B and 7B intensity-modulated radiation therapy plans. Differences among plans were evaluated using a two-tailed Friedman test at a statistical significance of p < 0.05. The maximum dose, average dose, and the conformity index (CI) of planning target volume 1 (PTV1) were similar for 3 plans for each case. No significant difference of coverage for planning target volume 1 and maximum dose for spinal cords were observed among 3 plans in present study (p > 0.05). The average V 5 , V 13 , V 20 , mean lung dose, and generalized equivalent uniform dose (gEUD) for the total lung were significantly lower in 4B-plans than those data in 5B-plans and 7B-plans (p < 0.01). Although the average V 30 for the total lung were significantly higher in 4B-plans than those in 5B-plans and 7B-plans (p < 0.05). In addition, when comparing with the 4B-plans, the conformity/heterogeneity index of the 5B- and 7B-plans were significantly superior (p < 0.05). The 4B-intensity-modulated radiation therapy plan has advantage to address the specialized problem of lung sparing to low- and intermediate-dose exposure in the thorax when dealing with relative long tumors extended inferiorly to the thoracic esophagus for upper esophageal carcinoma with the cost for less conformity. Studies are needed to compare the superiority of volumetric modulated arc therapy with intensity-modulated radiation therapy technique. Copyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  12. Comparison of PDR brachytherapy and external beam radiation therapy in the case of breast cancer

    NASA Astrophysics Data System (ADS)

    Teymournia, L.; Berger, D.; Kauer-Dorner, D.; Poljanc, K.; Seitz, W.; Aiginger, H.; Kirisits, C.

    2009-04-01

    Pulsed dose rate brachytherapy (PDR) was compared to external beam radiation therapy (EBRT) in the case of breast cancer. The benefits were figured out by evaluation of dosimetric parameters and calculating the normal tissue complication probability (NTCP). PDR plans were set up for five randomly chosen left-sided breast cancer patients delivering a total dose of 50.4 Gy to the target (dose rate 0.8 Gy h-1). For EBRT five left-sided breast cancer patients were planned using 3D-conformal tangential photon beams with a prescribed total dose of 50 Gy (2 Gy/fraction) to the total breast volume. For plan ranking and NTCP calculation the physical dose was first converted into the biologically effective dose (BED) and then into the normalized total dose (NTD) using the linear quadratic model with an α/β ratio of 3 Gy. In PDR the relative effectiveness (RE) was calculated for each dose bin of the differential dose volume histogram to get the BED. NTCPs were calculated for the ipsilateral lung and the heart as contoured on CT slices based on the Lyman model and the Kutcher reduction scheme. Dosimetric parameters as Vth (percentage of the total volume exceeding a threshold dose) and Jackson's fdam (fraction of the organ damaged) were also used to figure out the benefits. The comparison of calculated NTCPs in PDR and EBRT showed no difference between these two modalities. All values were below 0.01%. fdam derived from EBRT was always higher (mean value 8.95% versus 1.21% for the lung). The mean V10 and V20 of the lung related to BED were 6.32% and 1.72% for PDR versus 11.72% and 9.59% for EBRT. When using dosimetric parameters as Vth and fdam, PDR was mostly superior to EBRT in respect of sparing normal tissues. NTCP calculation as a single method of modality ranking showed a lack of information, especially when normal tissue was exposed to low radiation doses.

  13. Association Between Exercise Therapy Dose and Functional Improvements in the Early Postoperative Phase After Hip and Knee Arthroplasty: An Observational Study.

    PubMed

    Zech, Astrid; Hendrich, Simon; Pfeifer, Klaus

    2015-10-01

    To determine whether intensity and duration of standard exercise therapy are associated with changes in function after total hip arthroplasty (THA) and total knee arthroplasty (TKA). Prospective cohort study. Orthopedic inpatient rehabilitation center. A total of 123 patients 2 weeks after THA (n = 58; age, 62.5 ± 10.4 years) and TKA (n = 65; age, 66.6 ± 7.6 years). Standard rehabilitation (hands-on physiotherapy, group exercise therapy, strength training, cycle ergometer therapy, continuous passive motion therapy, and water exercise therapy). The Western Ontario and McMaster Universities Arthritis Index (WOMAC) and hip and knee range of motion (ROM) were assessed before and after inpatient rehabilitation. The individual rehabilitation period varied between 12-25 days and included 48.1 ± 12.5 (THA) or 41.9 ± 9.7 (TKA) exercise interventions with intensities between 9.6 and 14.0 points on the Borg Rate of Perceived Exertion Scale. WOMAC pain (P < .001), stiffness (P < .001), and function (P < .001), as well as hip (P < .001) and knee (P < .001) ROM, improved significantly in THA and TKA patients. Analysis of covariance showed that these changes could not be explained by the total duration or mean intensity of exercise therapy. The findings show a low dose-response relationship between early postoperative exercise therapy and the improvements in function or ROM after THA and TKA. Although the findings raise questions about the efficacy of existing rehabilitation programs, the small sample size, single setting, and geographic differences in postoperative treatment standards limit the generalizability of findings. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  14. Differences in Normal Tissue Response in the Esophagus Between Proton and Photon Radiation Therapy for Non-Small Cell Lung Cancer Using In Vivo Imaging Biomarkers.

    PubMed

    Niedzielski, Joshua S; Yang, Jinzhong; Mohan, Radhe; Titt, Uwe; Mirkovic, Dragan; Stingo, Francesco; Liao, Zhongxing; Gomez, Daniel R; Martel, Mary K; Briere, Tina M; Court, Laurence E

    2017-11-15

    To determine whether there exists any significant difference in normal tissue toxicity between intensity modulated radiation therapy (IMRT) or proton therapy for the treatment of non-small cell lung cancer. A total of 134 study patients (n=49 treated with proton therapy, n=85 with IMRT) treated in a randomized trial had a previously validated esophageal toxicity imaging biomarker, esophageal expansion, quantified during radiation therapy, as well as esophagitis grade (Common Terminology Criteria for Adverse Events version 3.0), on a weekly basis during treatment. Differences between the 2 modalities were statically analyzed using the imaging biomarker metric value (Kruskal-Wallis analysis of variance), as well as the incidence and severity of esophagitis grade (χ 2 and Fisher exact tests, respectively). The dose-response of the imaging biomarker was also compared between modalities using esophageal equivalent uniform dose, as well as delivered dose to an isotropic esophageal subvolume. No statistically significant difference in the distribution of esophagitis grade, the incidence of grade ≥3 esophagitis (15 and 11 patients treated with IMRT and proton therapy, respectively), or the esophageal expansion imaging biomarker between cohorts (P>.05) was found. The distribution of imaging biomarker metric values had similar distributions between treatment arms, despite a slightly higher dose volume in the proton arm (P>.05). Imaging biomarker dose-response was similar between modalities for dose quantified as esophageal equivalent uniform dose and delivered esophageal subvolume dose. Regardless of treatment modality, there was high variability in imaging biomarker response, as well as esophagitis grade, for similar esophageal doses between patients. There was no significant difference in esophageal toxicity from either proton- or photon-based radiation therapy as quantified by esophagitis grade or the esophageal expansion imaging biomarker. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Effects of low-dose light-emitting-diode therapy in combination with water bath for atopic dermatitis in NC/Nga mice.

    PubMed

    Kim, Chang-Hyun; Cheong, Kyung Ah; Lim, Won Suk; Park, Hyung-Moo; Lee, Ai-Young

    2016-01-01

    Light-emitting diode (LED) phototherapy and water bath therapy have beneficial effect on atopic dermatitis (AD)-like skin disease. However, not all current treatments work well and alternative therapies are need. The contribution of combination therapy with low-dose 850 nm LED and water bath was investigated on dermatophagoides farina (Df)-induced dermatitis in NC/Nga mice. Low-dose LED (10, 15, and 20 J/cm(2) ) irradiation, water bath (36 ± 1°C) were administered separately and together to the Df-induced NC/Nga mice in acrylic jar once a day for 2 weeks. Combined therapy with low-dose LED therapy and water bath therapy significantly ameliorated the development of AD-like skin lesions. These effects were correlated with the suppression of total IgE, NO, histamine, and Th2-mediated immune responses. Furthermore, combination therapy significantly reduced the infiltration of inflammatory cells and the induction of thymic stromal lymphopoietin (TSLP) in the skin lesions. The beneficial therapeutic effects of this combination therapy might regulate by the inhibition of various immunological responses including Th2-mediated immune responses, inflammatory mediators such as IgE, histamine, and NO, as well as inflammatory cells. The combination therapy of LED and water bath might be used as an efficacious, safe, and steroid-free alternative therapeutic strategy for the treatment of AD. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. GONAD DOSES IN THE X IRRADIATION OF SOME SO-CALLED MILD ILLNESSES (in German)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glauner, R.; Messner, D.; Thelen, P.O.

    1958-10-01

    Measurements of gonad doses were carried out on men and women using ionization chambers. In women the measurements were made in the vagina. Gonad doses were measured in patients who received x-ray therapy for puerperal mastitis, sweat gland abscesses in the axilla, and furunculi of the face. The conditions of irradiation, as well as the single and total doses, are briefiy discussed. Various means of reducing gonad dose are discussed in detail. (auth)

  17. SU-E-J-124: 18F-FDG PET Imaging to Improve RT Treatment Outcome for Locally Advanced Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shusharina, N; Khan, F; Sharp, G

    2015-06-15

    Purpose: To investigate spatial correlation between high uptake regions of pre- and 10-days-post therapy{sup 1} {sup 8}F-FDG PET in recurrent lung cancer and to evaluate the feasibility of dose escalation boosting only regions with high FDG uptake identified on baseline PET. Methods: Nineteen patients with stages II– IV inoperable lung cancer were selected. Volumes of interest (VOI) on pre-therapy FDG-PET were defined using an isocontour at ≥50% of SUVmax. VOI of pre- and post-therapy PET images were correlated for the extent of overlap. A highly optimized IMRT plan to 60 Gy prescribed to PTV defined on the planning CT wasmore » designed using clinical dose constraints for the organs at risk. A boost of 18 Gy was prescribed to the VOI defined on baseline PET. A composite plan of the total 78 Gy was compared with the base 60 Gy plan. Increases in dose to the lungs, spinal cord and heart were evaluated. IMRT boost plan was compared with proton RT and SBRT boost plans. Results: Overlap fraction of baseline PET VOI with the VOI on 10 days-post therapy PET was 0.8 (95% CI: 0.7 – 0.9). Using baseline VOI as a boosting volume, dose could be escalated to 78 Gy for 15 patients without compromising the dose constraints. For 4 patients, the dose limiting factors were V20Gy and Dmean for the total lung, and Dmax for the spinal cord. An increase of the dose to OARs correlated significantly with the relative size of the boost volume. Conclusion: VOI defined on baseline 18F-FDG PET by the SUVmax-≥50% isocontour may be a biological target volume for escalated radiation dose. Dose escalation to this volume may provide improved tumor control without breaching predefined dose constraints for OARs. The best treatment outcome may be achieved with proton RT for large targets and with SBRT for small targets.« less

  18. VMAT vs. 7-Field-IMRT: Assessing the Dosimetric Parameters of Prostate Cancer Treatment with a 292-Patient Sample

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kopp, Robert W.; Duff, Michael, E-mail: mduff@cancercarewny.com; Catalfamo, Frank

    2011-01-01

    We compared normal tissue radiation dose for the treatment of prostate cancer using 2 different radiation therapy delivery methods: volumetric modulated arc therapy (VMAT) vs. fixed-field intensity-modulated radiation therapy (IMRT). Radiotherapy plans for 292 prostate cancer patients treated with VMAT to a total dose of 7740 cGy were analyzed retrospectively. Fixed-angle, 7-field IMRT plans were created using the same computed tomography datasets and contours. Radiation doses to the planning target volume (PTV) and organs at risk (bladder, rectum, penile bulb, and femoral heads) were measured, means were calculated for both treatment methods, and dose-volume comparisons were made with 2-tailed, pairedmore » t-tests. The mean dose to the bladder was lower with VMAT at all measured volumes: 5, 10, 15, 25, 35, and 50% (p < 0.05). The mean doses to 5 and 10% of the rectum, the high-dose regions, were lower with VMAT (p < 0.05). The mean dose to 15% of the rectal volume was not significantly different (p = 0.95). VMAT exposed larger rectal volumes (25, 35, and 50%) to more radiation than fixed-field IMRT (p < 0.05). Average mean dose to the penile bulb (p < 0.05) and mean dose to 10% of the femoral heads (p < 0.05) were lower with VMAT. VMAT therapy for prostate cancer has dosimetric advantages for critical structures, notably for high-dose regions compared with fixed-field IMRT, without compromising PTV coverage. This may translate into reduced acute and chronic toxicity.« less

  19. Whole-brain hippocampal sparing radiation therapy: Volume-modulated arc therapy vs intensity-modulated radiation therapy case study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Katrina, E-mail: Trinabena23@gmail.com; Lenards, Nishele; Holson, Janice

    The hippocampus is responsible for memory and cognitive function. An ongoing phase II clinical trial suggests that sparing dose to the hippocampus during whole-brain radiation therapy can help preserve a patient's neurocognitive function. Progressive research and advancements in treatment techniques have made treatment planning more sophisticated but beneficial for patients undergoing treatment. The aim of this study is to evaluate and compare hippocampal sparing whole-brain (HS-WB) radiation therapy treatment planning techniques using volume-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT). We randomly selected 3 patients to compare different treatment techniques that could be used for reducing dose to themore » hippocampal region. We created 2 treatment plans, a VMAT and an IMRT, from each patient's data set and planned on the Eclipse 11.0 treatment planning system (TPS). A total of 6 plans (3 IMRT and 3 VMAT) were created and evaluated for this case study. The physician contoured the hippocampus as per the Radiation Therapy Oncology Group (RTOG) 0933 protocol atlas. The organs at risk (OR) were contoured and evaluated for the plan comparison, which included the spinal cord, optic chiasm, the right and left eyes, lenses, and optic nerves. Both treatment plans produced adequate coverage on the planning target volume (PTV) while significantly reducing dose to the hippocampal region. The VMAT treatment plans produced a more homogenous dose distribution throughout the PTV while decreasing the maximum point dose to the target. However, both treatment techniques demonstrated hippocampal sparing when irradiating the whole brain.« less

  20. SU-E-T-812: Volumetric Modulated Arc Therapy-Total Body Irradiation (VMAT-TBI) V.s. Conventional Extended SSD-TBI (cTBI): A Dosimetric Comparisom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ouyang, L; Folkerts, M; Lee, H

    2015-06-15

    Purpose: To perform a dosimetric evaluation on a new developed volumetric modulated arc therapy based total body irradiation (VMAT-TBI). Methods: Three patients were CT scanned with an indexed rotatable body frame to get whole body CT images. Concatenated CT images were imported in Pinnacle treatment planning system and whole body and lung were contoured as PTV and organ at risk, respectively. Treatment plans were generated by matching multiple isocenter volumetric modulated arc (VMAT) fields of the upper body and multiple isocenter parallel-opposed fields of the lower body. For each plan, 1200 cGy in 8 fractions was prescribed to the wholemore » body volume and the lung dose was constrained to a mean dose of 750 cGy. Such a two-level dose plan was achieved by inverse planning of the torso VMAT fields. For comparison, conventional standing TBI (cTBI) plans were generated on the same whole body CT images at an extended SSD (550cm).The shape of compensators and lung blocks are simulated using body segments and lung contours Compensation was calculated based on the patient CT images, in mimic of the standing TBI treatment. The whole body dose distribution of cTBI plans were calculated with a home-developed GPU Monte Carlo dose engine. Calculated cTBI dose distribution was prescribed to the mid-body point at umbilical level. Results: The VMAT-TBI treatment plans of three patients’ plans achieved 80.2%±5.0% coverage of the total body volume within ±10% of the prescription dose, while cTBI treatment plans achieved 72.2%±4.0% coverage of the total body volume. The averaged mean lung dose of all three patients is lower for VMAT-TBI (7.48 cGy) than for cTBI (8.96 cGy). Conclusion: The proposed patient comfort-oriented VMAT-TBI technique provides for a uniform dose distribution within the total body while reducing the dose to the lungs.« less

  1. Predictors of High-grade Esophagitis After Definitive Three-dimensional Conformal Therapy, Intensity-modulated Radiation Therapy, or Proton Beam Therapy for Non-small cell Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gomez, Daniel R., E-mail: dgomez@mdanderson.org; Tucker, Susan L.; Martel, Mary K.

    2012-11-15

    Introduction: We analyzed the ability of various patient- and treatment-related factors to predict radiation-induced esophagitis (RE) in patients with non-small cell lung cancer (NSCLC) treated with three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), or proton beam therapy (PBT). Methods and Materials: Patients were treated for NSCLC with 3D-CRT, IMRT, or PBT at MD Anderson from 2000 to 2008 and had full dose-volume histogram (DVH) data available. The endpoint was severe (grade {>=}3) RE. The Lyman-Kutcher-Burman (LKB) model was used to analyze RE as a function of the fractional esophageal DVH, with clinical variables included as dose-modifying factors. Results:more » Overall, 652 patients were included: 405 patients were treated with 3D-CRT, 139 with IMRT, and 108 with PBT; corresponding rates of grade {>=}3 RE were 8%, 28%, and 6%, respectively, with a median time to onset of 42 days (range, 11-93 days). A fit of the fractional DVH LKB model demonstrated that the fractional effective dose was significantly different (P=.046) than 1 (fractional mean dose) indicating that high doses to small volumes are more predictive than mean esophageal dose. The model fit was better for 3D-CRT and PBT than for IMRT. Including receipt of concurrent chemotherapy as a dose-modifying factor significantly improved the LKB model (P=.005), and the model was further improved by including a variable representing treatment with >30 fractions. Examining individual types of chemotherapy agents revealed a trend toward receipt of concurrent taxanes and increased risk of RE (P=.105). Conclusions: Fractional dose (dose rate) and number of fractions (total dose) distinctly affect the risk of severe RE, estimated using the LKB model, and concurrent chemotherapy improves the model fit. This risk of severe RE is underestimated by this model in patients receiving IMRT.« less

  2. Predictors of high-grade esophagitis after definitive three-dimensional conformal therapy, intensity-modulated radiation therapy, or proton beam therapy for non-small cell lung cancer.

    PubMed

    Gomez, Daniel R; Tucker, Susan L; Martel, Mary K; Mohan, Radhe; Balter, Peter A; Lopez Guerra, Jose Luis; Liu, Hongmei; Komaki, Ritsuko; Cox, James D; Liao, Zhongxing

    2012-11-15

    We analyzed the ability of various patient- and treatment-related factors to predict radiation-induced esophagitis (RE) in patients with non-small cell lung cancer (NSCLC) treated with three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), or proton beam therapy (PBT). Patients were treated for NSCLC with 3D-CRT, IMRT, or PBT at MD Anderson from 2000 to 2008 and had full dose-volume histogram (DVH) data available. The endpoint was severe (grade≥3) RE. The Lyman-Kutcher-Burman (LKB) model was used to analyze RE as a function of the fractional esophageal DVH, with clinical variables included as dose-modifying factors. Overall, 652 patients were included: 405 patients were treated with 3D-CRT, 139 with IMRT, and 108 with PBT; corresponding rates of grade≥3 RE were 8%, 28%, and 6%, respectively, with a median time to onset of 42 days (range, 11-93 days). A fit of the fractional DVH LKB model demonstrated that the fractional effective dose was significantly different (P=.046) than 1 (fractional mean dose) indicating that high doses to small volumes are more predictive than mean esophageal dose. The model fit was better for 3D-CRT and PBT than for IMRT. Including receipt of concurrent chemotherapy as a dose-modifying factor significantly improved the LKB model (P=.005), and the model was further improved by including a variable representing treatment with >30 fractions. Examining individual types of chemotherapy agents revealed a trend toward receipt of concurrent taxanes and increased risk of RE (P=.105). Fractional dose (dose rate) and number of fractions (total dose) distinctly affect the risk of severe RE, estimated using the LKB model, and concurrent chemotherapy improves the model fit. This risk of severe RE is underestimated by this model in patients receiving IMRT. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Pneumocystis jirovecii pneumonia induced by low-dose methotrexate in a patient with chronic urticaria.

    PubMed

    Wang, Sheng-Huei; Tang, Shih-En; Li, Yu-Huei; Wei, Kuang-Yu; Chang, Chan-Yuan

    2017-01-01

    Methotrexate has immunosuppressive effects and is administered for refractory chronic urticaria. We present a case of Pneumocystis jirovecii pneumonia in a patient with refractory chronic urticaria managed by low-dose weekly methotrexate treatment (total cumulative dose 195mg). Our study highlights the importance of providing prompt diagnosis and treatment of Pneumocystis jirovecii pneumonia in patients with chronic urticaria under methotrexate therapy.

  4. Increasing Use of Dose-Escalated External Beam Radiation Therapy for Men With Nonmetastatic Prostate Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swisher-McClure, Samuel, E-mail: Swisher-Mcclure@uphs.upenn.edu; Leonard Davis Institute of Health Economics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA; Mitra, Nandita

    Purpose: To examine recent practice patterns, using a large national cancer registry, to understand the extent to which dose-escalated external beam radiation therapy (EBRT) has been incorporated into routine clinical practice for men with prostate cancer. Methods and Materials: We conducted a retrospective observational cohort study using the National Cancer Data Base, a nationwide oncology outcomes database in the United States. We identified 98,755 men diagnosed with nonmetastatic prostate cancer between 2006 and 2011 who received definitive EBRT and classified patients into National Comprehensive Cancer Network (NCCN) risk groups. We defined dose-escalated EBRT as total prescribed dose of ≥75.6 Gy. Usingmore » multivariable logistic regression, we examined the association of patient, clinical, and demographic characteristics with the use of dose-escalated EBRT. Results: Overall, 81.6% of men received dose-escalated EBRT during the study period. The use of dose-escalated EBRT did not vary substantially by NCCN risk group. Use of dose-escalated EBRT increased from 70.7% of patients receiving treatment in 2006 to 89.8% of patients receiving treatment in 2011. On multivariable analysis, year of diagnosis and use of intensity modulated radiation therapy were significantly associated with receipt of dose-escalated EBRT. Conclusions: Our study results indicate that dose-escalated EBRT has been widely adopted by radiation oncologists treating prostate cancer in the United States. The proportion of patients receiving dose-escalated EBRT increased nearly 20% between 2006 and 2011. We observed high utilization rates of dose-escalated EBRT within all disease risk groups. Adoption of intensity modulated radiation therapy was strongly associated with use of dose-escalated treatment.« less

  5. Impact of Penicillin Allergy on Time to First Dose of Antimicrobial Therapy and Clinical Outcomes.

    PubMed

    Conway, Erin L; Lin, Ken; Sellick, John A; Kurtzhalts, Kari; Carbo, James; Ott, Michael C; Mergenhagen, Kari A

    2017-11-01

    The objective of this study was to evaluate the impact of a listed penicillin allergy on the time to first dose of antibiotic in a Veterans Affairs hospital. Additional clinical outcomes of patients with penicillin allergies were compared with those of patients without a penicillin allergy. A retrospective chart review of veterans admitted through the emergency department with a diagnosis of pneumonia, urinary tract infection, bacteremia, and sepsis from January 2006 to December 2015 was conducted. The primary outcome was time to first dose of antibiotic treatment, defined as the time from when the patient presented to the emergency department to the medication administration time. Secondary outcomes included total antibiotic therapy duration and treatment outcomes, including mortality, length of stay, and 30-day readmission rate. A total of 403 patients were included in the final analysis; 57 patients (14.1%) had a listed penicillin allergy. The average age of the population was 75 years and 99% of the population was male. The mean time to first dose of antibiotic treatment for patients with a penicillin allergy was prolonged compared with those without a penicillin allergy (236.1 vs 186.6 minutes; P = 0.03), resulting in an approximately 50-minute delay. Penicillin-allergic patients were more likely to receive a carbapenem or fluoroquinolone antibiotic (P < 0.0001). Patients with a penicillin allergy had a prolonged time to first dose of antibiotic therapy. No significant differences were found in total antibiotic duration, length of stay, or 30-day readmission rate. The small sample size, older population, and single-center nature of this study may limit the generalizability of the present findings to other populations. Published by Elsevier Inc.

  6. Functional image-guided stereotactic body radiation therapy planning for patients with hepatocellular carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsegmed, Uranchimeg; Kimura, Tomoki, E-mail: tkkimura@hiroshima-u.ac.jp; Nakashima, Takeo

    The aim of the current planning study is to evaluate the ability of gadoxetate disodium-enhanced magnetic resonance imaging (EOB-MRI)–guided stereotactic body radiation therapy (SBRT) planning by using intensity-modulated radiation therapy (IMRT) techniques in sparing the functional liver tissues during SBRT for hepatocellular carcinoma. In this study, 20 patients with hepatocellular carcinoma were enrolled. Functional liver tissues were defined according to quantitative liver-spleen contrast ratios ≥ 1.5 on a hepatobiliary phase scan. Functional images were fused with the planning computed tomography (CT) images; the following 2 SBRT plans were designed using a “step-and-shoot” static IMRT technique for each patient: (1) an anatomicalmore » SBRT plan optimization based on the total liver; and (2) a functional SBRT plan based on the functional liver. The total prescribed dose was 48 gray (Gy) in 4 fractions. Dosimetric parameters, including dose to 95% of the planning target volume (PTV D{sub 95%}), percentages of total and functional liver volumes, which received doses from 5 to 30 Gy (V5 to V30 and fV5 to fV30), and mean doses to total and functional liver (MLD and fMLD, respectively) of the 2 plans were compared. Compared with anatomical plans, functional image-guided SBRT plans reduced MLD (mean: plan A, 5.5 Gy; and plan F, 5.1 Gy; p < 0.0001) and fMLD (mean: plan A, 5.4 Gy; and plan F, 4.9 Gy; p < 0.0001), as well as V5 to V30 and fV5 to fV30. No differences were noted in PTV coverage and nonhepatic organs at risk (OARs) doses. In conclusion, EOB-MRI–guided SBRT planning using the IMRT technique may preserve functional liver tissues in patients with hepatocellular carcinoma (HCC).« less

  7. LACK OF CORRELATION BETWEEN OPIOID DOSE ADJUSTMENT AND PAIN SCORE CHANGE IN A GROUP OF CHRONIC PAIN PATIENTS

    PubMed Central

    Chen, Lucy; Vo, Trang; Seefeld, Lindsey; Malarick, Charlene; Houghton, Mary; Ahmed, Shihab; Zhang, Yi; Cohen, Abigail; Retamozo, Cynthia; Hilaire, Kristen St.; Zhang, Vivian; Mao, Jianren

    2013-01-01

    Despite the increasing use of opioid analgesics for chronic pain management, it is unclear whether opioid dose escalation leads to better pain relief during chronic opioid therapy. In this study, we retrospectively analyzed clinical data collected from the Massachusetts General Hospital (MGH) Center for Pain Medicine over a 7-year period. We examined 1) the impact of opioid dose adjustment (increase or decrease) on clinical pain score, 2) gender and age differences in response to opioid therapy, and 3) the influence of clinical pain conditions on the opioid analgesic efficacy. A total of 109 subjects met the criteria for data collection. We found that neither opioid dose increase, nor decrease, correlated with point changes in clinical pain score in a subset of chronic pain patients over a prolonged course of opioid therapy (an average of 704 days). This lack of correlation was consistent regardless of the type of chronic pain including neuropathic, nociceptive, or mixed pain conditions. Neither gender nor age differences showed a significant influence on the clinical response to opioid therapy in these subjects. These results suggest that dose adjustment during opioid therapy may not necessarily alter long-term clinical pain score in a group of chronic pain patients and that individualized opioid therapy based on the clinical effectiveness should be considered to optimize the treatment outcome. Perspectives The study reports a relationship, or lack thereof, between opioid dose change and clinical pain score in a group of chronic pain patients. The study also calls for further investigation into the effectiveness of opioid therapy in the management of chronic non-malignant pain conditions. PMID:23452826

  8. Cost analytic model to determine the least costly inpatient erythropoiesis stimulating therapy regimen.

    PubMed

    Sikand, Harminder; Decter, Adam; Greco, Tina; Watson, Sue H; Kang, Yoon Jun; Mody, Samir H; Piech, Catherine Tak; Duh, Mei Sheng; Naeem, Ayesha

    2008-01-01

    Unlike in outpatient settings, the comparative costs of epoetin alpha (EPO) and darbepoetin alpha (DARB) have not been evaluated broadly from the inpatient hospital perspective. To develop a cost analytic model comparing hospital inpatient costs for erythropoiesis stimulating therapies within the nephrology and oncology settings. A cost analytic model incorporating erythropoietic drug, pharmacy, and nursing costs was developed from the inpatient hospital perspective to evaluate comparative costs of EPO and DARB. Erythropoietic drug costs were calculated using unit wholesale acquisition cost multiplied by the number of units or micrograms while comparing the following dosing regimens: EPO 3 times weekly, EPO once weekly, and DARB once weekly. Pharmacy costs included dispensing and delivery costs, while nursing costs incorporated administration time costs; all were calculated by estimated fractional hours per activity multiplied by hourly wages. The total frequency of erythropoiesis stimulating therapy administrations was determined based on the average hospital length of stay. The first erythropoiesis stimulating therapy dose was assumed to occur on day 3 of hospitalization. For total inpatient costs, a weighted average was calculated across disease states. One-way sensitivity analyses were conducted by varying length of stay, day of initial erythropoiesis stimulating therapy dose, pharmacy and nursing costs, and once-weekly DARB dose. EPO 3 times weekly was the least costly regimen across all disease states evaluated. Threshold analysis indicated that the cost of once-weekly DARB regimens would have to be reduced by 37% to equal the cost of EPO 3 times weekly for an average length of stay. Sensitivity analyses did not considerably affect the results. EPO 3 times weekly was found to be the least costly erythropoiesis stimulating therapy regimen for nephrology and oncology inpatients for the average length of stay as well as most other lengths of stay considered. Once-weekly EPO was the least costly erythropoiesis stimulating therapy regimen for several other lengths of stay, while once-weekly DARB was never found to be the least costly regimen.

  9. [Usefulness of Bolus Administration Using the FLEX Mode(Bolus Infusion Mode)for Baclofen Tolerance].

    PubMed

    Tanaka, Kazunori

    2017-02-01

    Intrathecal baclofen(ITB)is used to treat intractable spasticity of various etiologies and can provide better control of spasticity through the adjustment of the dose administered through the pump. However, in patients who develop tolerance to baclofen with the standard simple continuous mode, a sharp increase in dose becomes necessary, and spasticity can become harder to control. We investigated whether switching from the simple continuous mode to the bolus infusion mode was effective in controlling spasticity in patients with baclofen tolerance. We reported four patients undergoing ITB therapy at our facility who were considered to have developed baclofen tolerance. We observed the number of bolus infusions and total dose suitable for maintaining spasticity control after switching from the simple continuous mode to the bolus infusion mode. After switching to the bolus infusion mode, the total dose could be reduced in the short term; however, in the long term, the frequency of bolus infusions had to be increased to maintain spasticity control. Two years after changing to bolus infusion six times a day, the total dose was higher than that in the simple continuous mode for two of the four patients, and was the same level in the other two patients. Our four cases suggest that bolus infusion is effective in patients with baclofen tolerance during ITB therapy. Therefore, the conditions of bolus infusion should be further investigated.

  10. Radiation Dose-Response Model for Locally Advanced Rectal Cancer After Preoperative Chemoradiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Appelt, Ane L., E-mail: ane.lindegaard.appelt@slb.regionsyddanmark.dk; University of Southern Denmark, Odense; Ploen, John

    2013-01-01

    Purpose: Preoperative chemoradiation therapy (CRT) is part of the standard treatment of locally advanced rectal cancers. Tumor regression at the time of operation is desirable, but not much is known about the relationship between radiation dose and tumor regression. In the present study we estimated radiation dose-response curves for various grades of tumor regression after preoperative CRT. Methods and Materials: A total of 222 patients, treated with consistent chemotherapy and radiation therapy techniques, were considered for the analysis. Radiation therapy consisted of a combination of external-beam radiation therapy and brachytherapy. Response at the time of operation was evaluated from themore » histopathologic specimen and graded on a 5-point scale (TRG1-5). The probability of achieving complete, major, and partial response was analyzed by ordinal logistic regression, and the effect of including clinical parameters in the model was examined. The radiation dose-response relationship for a specific grade of histopathologic tumor regression was parameterized in terms of the dose required for 50% response, D{sub 50,i}, and the normalized dose-response gradient, {gamma}{sub 50,i}. Results: A highly significant dose-response relationship was found (P=.002). For complete response (TRG1), the dose-response parameters were D{sub 50,TRG1} = 92.0 Gy (95% confidence interval [CI] 79.3-144.9 Gy), {gamma}{sub 50,TRG1} = 0.982 (CI 0.533-1.429), and for major response (TRG1-2) D{sub 50,TRG1} and {sub 2} = 72.1 Gy (CI 65.3-94.0 Gy), {gamma}{sub 50,TRG1} and {sub 2} = 0.770 (CI 0.338-1.201). Tumor size and N category both had a significant effect on the dose-response relationships. Conclusions: This study demonstrated a significant dose-response relationship for tumor regression after preoperative CRT for locally advanced rectal cancer for tumor dose levels in the range of 50.4-70 Gy, which is higher than the dose range usually considered.« less

  11. Uncertainties in endocrine substitution therapy for central hypocortisolism.

    PubMed

    Swords, Francesca M

    2014-01-01

    Central hypocortisolism is common, and has multiple potential causes. However, the treatment aims remain the same whatever the cause: to maximize quality of life, while minimizing treatment-related adverse effects. The majority of patients with central hypocortisolism now receive hydrocortisone in two to three divided doses with a total daily dose of 10-20mg, or a weight-based regimen of 8.1mg/m(2)/day. However, various areas of controversy remain: how to assess the patient with suspected hypocortisolism, which is the optimal agent to use, what is the optimal total daily dose, how to administer divided daily doses, how to monitor therapy and individually tailor doses, whether to replace other adrenal androgens, how to approach the patient with adrenal suppression, and how to best educate patients with hypocortisolism and treat them in emergency situations. This chapter will discuss the evidence behind each of these controversial areas in turn. The evidence for newer agents such as prolonged- and delayed-release preparations of hydrocortisone will also be explored, with a discussion on their potential role in the future management of this major clinical problem. © 2014 Elsevier B.V. All rights reserved.

  12. Once-weekly exenatide as adjunct treatment of type 1 diabetes mellitus in patients receiving continuous subcutaneous insulin infusion therapy.

    PubMed

    Traina, Andrea N; Lull, Melinda E; Hui, Adrian C; Zahorian, Toni M; Lyons-Patterson, Jane

    2014-08-01

    The use of once-weekly exenatide in type 2 diabetes mellitus is well supported, but little is known about its effectiveness in type 1 diabetes. The objective of this study was to determine the clinical efficacy of once-weekly exenatide on glycemic control in patients with type 1 diabetes when added to basal-bolus insulin therapy. For this retrospective study, patients with type 1 diabetes, aged 18 years and older, receiving continuous subcutaneous insulin infusion, using a continuous glucose monitoring device or regularly measuring blood glucose levels and receiving 2 mg of exenatide once weekly for at least 3 months were included. Demographic information, glycated hemoglobin (A1C), body weight, body mass index, systolic and diastolic blood pressures, total daily insulin dose, basal and bolus insulin doses, 28-day continuous subcutaneous insulin infusion glucose average and incidence of hypoglycemia were collected at baseline and 3 months after beginning therapy with once-weekly exenatide. An electronic medical record search identified 11 patients with type 1 diabetes who met the inclusion criteria. Comparing baseline and 3 months after initiation of once-weekly exenatide revealed reductions of 0.6% in A1C (p=0.013), 3.7% in body weight (p=0.008), 1.7 kg/m(2) in body mass index (p=0.003), 13% in total daily insulin dose (p=0.011) and 9.3 units in bolus insulin dose (p=0.015). This study revealed that the addition of once-weekly exenatide to insulin therapy for type 1 diabetes patients leads to significant improvements in A1C, body weight, body mass index and insulin doses. Copyright © 2014 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.

  13. Precision Hypofractionated Radiation Therapy in Poor Performing Patients With Non-Small Cell Lung Cancer: Phase 1 Dose Escalation Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Westover, Kenneth D.; Loo, Billy W.; Gerber, David E.

    2015-09-01

    Purpose: Treatment regimens for locally advanced non-small cell lung cancer (NSCLC) give suboptimal clinical outcomes. Technological advancements such as radiation therapy, the backbone of most treatment regimens, may enable more potent and effective therapies. The objective of this study was to escalate radiation therapy to a tumoricidal hypofractionated dose without exceeding the maximally tolerated dose (MTD) in patients with locally advanced NSCLC. Methods and Materials: Patients with stage II to IV or recurrent NSCLC and Eastern Cooperative Oncology Group performance status of 2 or greater and not candidates for surgical resection, stereotactic radiation, or concurrent chemoradiation were eligible. Highly conformal radiationmore » therapy was given to treat intrathoracic disease in 15 fractions to a total of 50, 55, or 60 Gy. Results: Fifty-five patients were enrolled: 15 at the 50-Gy, 21 at the 55-Gy, and 19 at the 60-Gy dose levels. A 90-day follow-up was completed in each group without exceeding the MTD. With a median follow-up of 12.5 months, there were 93 grade ≥3 adverse events (AEs), including 39 deaths, although most AEs were considered related to factors other than radiation therapy. One patient from the 55- and 60-Gy dose groups developed grade ≥3 esophagitis, and 5, 4, and 4 patients in the respective dose groups experienced grade ≥3 dyspnea, but only 2 of these AEs were considered likely related to therapy. There was no association between fraction size and toxicity (P=.24). The median overall survival was 6 months with no significant differences between dose levels (P=.59). Conclusions: Precision hypofractionated radiation therapy consisting of 60 Gy in 15 fractions for locally advanced NSCLC is generally well tolerated. This treatment regimen could provide patients with poor performance status a potent alternative to chemoradiation. This study has implications for the cost effectiveness of lung cancer therapy. Additional studies of long-term safety and efficacy of this therapy are warranted.« less

  14. Estimation of the risk of secondary malignancy arising from whole-breast irradiation: comparison of five radiotherapy modalities, including TomoHDA.

    PubMed

    Han, Eun Young; Paudel, Nava; Sung, Jiwon; Yoon, Myonggeun; Chung, Weon Kuu; Kim, Dong Wook

    2016-04-19

    The risk of secondary cancer from radiation treatment remains a concern for long-term breast cancer survivors, especially those treated with radiation at the age younger than 45 years. Treatment modalities optimally maximize the dose delivery to the tumor while minimizing radiation doses to neighboring organs, which can lead to secondary cancers. A new TomoTherapy treatment machine, TomoHDATM, can treat an entire breast with two static but intensity-modulated beams in a slice-by-slice fashion. This feature could reduce scattered and leakage radiation doses. We compared the plan quality and lifetime attributable risk (LAR) of a second malignancy among five treatment modalities: three-dimensional conformal radiation therapy, field-in-field forward-planned intensity-modulated radiation therapy, inverse-planned intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy, and TomoDirect mode on the TomoHDA system. Ten breast cancer patients were selected for retrospective analysis. Organ equivalent doses, plan characteristics, and LARs were compared. Out-of-field organ doses were measured with radio-photoluminescence glass dosimeters. Although the IMRT plan provided overall better plan quality, including the lowest probability of pneumonitis, it caused the second highest LAR. The TomoTherapy plan provided plan quality comparable to the IMRT plan and posed the lowest total LAR to neighboring organs. Therefore, it can be a better treatment modality for younger patients who have a longer life expectancy.

  15. TH-EF-BRB-11: Volumetric Modulated Arc Therapy for Total Body Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ouyang, L; Folkerts, M; Hrycushko, B

    Purpose: To develop a modern, patient-comfortable total body irradiation (TBI) technique suitable for standard-sized linac vaults. Methods: An indexed rotatable immobilization system (IRIS) was developed to make possible total-body CT imaging and radiation delivery on conventional couches. Treatment consists of multi-isocentric volumetric modulated arc therapy (VMAT) to the upper body and parallel-opposed fields to the lower body. Each isocenter is indexed to the couch and includes a 180° IRIS rotation between the upper and lower body fields. VMAT fields are optimized to satisfy lung dose objectives while achieving a uniform therapeutic dose to the torso. End-to-end tests with a randomore » phantom were used to verify dosimetric characteristics. Treatment plan robustness regarding setup uncertainty was assessed by simulating global and regional isocenter setup shifts on patient data sets. Dosimetric comparisons were made with conventional extended distance, standing TBI (cTBI) plans using a Monte Carlo-based calculation. Treatment efficiency was assessed for eight courses of patient treatment. Results: The IRIS system is level and orthogonal to the scanned CT image plane, with lateral shifts <2mm following rotation. End-to-end tests showed surface doses within ±10% of the prescription dose, field junction doses within ±15% of prescription dose. Plan robustness tests showed <15% changes in dose with global setup errors up to 5mm in each direction. Local 5mm relative setup errors in the chest resulted in < 5% dose changes. Local 5mm shift errors in the pelvic and upper leg junction resulted in <10% dose changes while a 10mm shift error causes dose changes up to 25%. Dosimetric comparison with cTBI showed VMAT-TBI has advantages in preserving chest wall dose with flexibility in leveraging the PTV-body and PTV-lung dose. Conclusion: VMAT-TBI with the IRIS system was shown clinically feasible as a cost-effective approach to TBI for standard-sized linac vaults.« less

  16. Intravenous Iron Therapy in Patients with Iron Deficiency Anemia: Dosing Considerations

    PubMed Central

    Myers, Jennifer; Goodnough, Lawrence Tim

    2015-01-01

    Objective. To provide clinicians with evidence-based guidance for iron therapy dosing in patients with iron deficiency anemia (IDA), we conducted a study examining the benefits of a higher cumulative dose of intravenous (IV) iron than what is typically administered. Methods. We first individually analyzed 5 clinical studies, averaging the total iron deficit across all patients utilizing a modified Ganzoni formula; we then similarly analyzed 2 larger clinical studies. For the second of the larger studies (Study 7), we also compared the efficacy and retreatment requirements of a cumulative dose of 1500 mg ferric carboxymaltose (FCM) to 1000 mg iron sucrose (IS). Results. The average iron deficit was calculated to be 1531 mg for patients in Studies 1–5 and 1392 mg for patients in Studies 6-7. The percentage of patients who were retreated with IV iron between Days 56 and 90 was significantly (p < 0.001) lower (5.6%) in the 1500 mg group, compared to the 1000 mg group (11.1%). Conclusions. Our data suggests that a total cumulative dose of 1000 mg of IV iron may be insufficient for iron repletion in a majority of patients with IDA and a dose of 1500 mg is closer to the actual iron deficit in these patients. PMID:26257955

  17. Determinants of medication adherence to topical glaucoma therapy.

    PubMed

    Dreer, Laura E; Girkin, Christopher; Mansberger, Steven L

    2012-01-01

    To determine the associations between medical, demographic, socioeconomic, and ocular factors and adherence to topical glaucoma ocular hypotensive therapy. One hundred sixteen patients with ocular hypertension or open-angle glaucoma from 2 tertiary glaucoma services participated in this prospective study. Adherence to ocular hypotensive therapy was measured using an electronic dose monitor (Travatan Dosing Aid, Alcon Laboratories Inc., Fort Worth, TX) and collected data at 3 months after enrollment. We used 3 different definitions of adherence: 1) Definition 1: the proportion of days taking the prescribed number of drops within 3 hours of the prescribed dosing time; 2) Definition 2: the proportion of days taking any drops within 3 hours of the prescribed dosing time; and 3) Definition 3: the proportion of days taking any drops within 6 hours of the prescribed dosing time. Univariate and multivariate models were used to determine the association between the 3 adherence definitions, medical, demographic, socioeconomic, and ocular factors at 3-month follow-up. The main outcome measures for this study were risk factors for poor objective medication adherence. Adherence, using Definition 1, Definition 2, and Definition 3, was 64%, 75%, and 80%, respectively. Age, total number of other eye diseases, and race were significantly associated with full treatment adherence (Definition 1), with race alone significantly predicting 11% of full treatment adherence. For Definition 2, age, income, level of education, and total number of eye diseases were significantly associated with partial adherence (3 h), again race alone significantly predicted 15% of partial adherence (any drops within 3 h). For Definition 3, race, income, level of education, and total number of other eye diseases significantly predicted partial adherence (any drops within 6 h), both race and income predicted 19% of partial treatment adherence. Significant differences for adherence rates between patients of European descent and those of African descent were found for all 3 definitions with those who were less adherent more likely to be of African descent. Electronic dose monitors provide important information regarding adherence to topical ocular hypotensive medications in glaucoma patients. Electronic dose monitors show low adherence in a significant number of participants. Future studies are needed to determine the reasons for these differences in health behaviors related to glaucoma treatment, which should guide treatment of poor adherence with glaucoma therapy.

  18. Pathogen-Reduced, Plasmalyte-Extended Stored Platelets (PREPS)

    DTIC Science & Technology

    2013-10-01

    if the 1:1:1 strategy is failing, the use of warm FWB is permitted. Such intensive plasma-based therapy early in resuscitation has led to a 50...radiolabeled with 51Cr or 111In. On that day, the subject will return to the Blood Center and provide a 43 mL fresh blood sample. Platelets from...will be infused. The total radiation dose is approximately 40 µCi for a total body absorbed dose of 0.0273 rad (0.273 mSv) and a splenic absorbed

  19. Whole-brain hippocampal sparing radiation therapy: Volume-modulated arc therapy vs intensity-modulated radiation therapy case study.

    PubMed

    Lee, Katrina; Lenards, Nishele; Holson, Janice

    2016-01-01

    The hippocampus is responsible for memory and cognitive function. An ongoing phase II clinical trial suggests that sparing dose to the hippocampus during whole-brain radiation therapy can help preserve a patient׳s neurocognitive function. Progressive research and advancements in treatment techniques have made treatment planning more sophisticated but beneficial for patients undergoing treatment. The aim of this study is to evaluate and compare hippocampal sparing whole-brain (HS-WB) radiation therapy treatment planning techniques using volume-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT). We randomly selected 3 patients to compare different treatment techniques that could be used for reducing dose to the hippocampal region. We created 2 treatment plans, a VMAT and an IMRT, from each patient׳s data set and planned on the Eclipse 11.0 treatment planning system (TPS). A total of 6 plans (3 IMRT and 3 VMAT) were created and evaluated for this case study. The physician contoured the hippocampus as per the Radiation Therapy Oncology Group (RTOG) 0933 protocol atlas. The organs at risk (OR) were contoured and evaluated for the plan comparison, which included the spinal cord, optic chiasm, the right and left eyes, lenses, and optic nerves. Both treatment plans produced adequate coverage on the planning target volume (PTV) while significantly reducing dose to the hippocampal region. The VMAT treatment plans produced a more homogenous dose distribution throughout the PTV while decreasing the maximum point dose to the target. However, both treatment techniques demonstrated hippocampal sparing when irradiating the whole brain. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  20. Dosimetric comparison between proton beam therapy and photon radiation therapy for locally advanced esophageal squamous cell carcinoma.

    PubMed

    Hirano, Yasuhiro; Onozawa, Masakatsu; Hojo, Hidehiro; Motegi, Atsushi; Zenda, Sadatomo; Hotta, Kenji; Moriya, Shunsuke; Tachibana, Hidenobu; Nakamura, Naoki; Kojima, Takashi; Akimoto, Tetsuo

    2018-02-09

    The purpose of this study was to perform a dosimetric comparison between proton beam therapy (PBT) and photon radiation therapy in patients with locally advanced esophageal squamous cell carcinoma (ESCC) who were treated with PBT in our institution. In addition, we evaluated the correlation between toxicities and dosimetric parameters, especially the doses to normal lung or heart tissue, to clarify the clinical advantage of PBT over photon radiation therapy. A total of 37 consecutive patients with Stage III thoracic ESCC who had received PBT with or without concurrent chemotherapy between October 2012 and December 2015 were evaluated in this study. The dose distributions of PBT were compared with those of dummy 3-dimensional conformal radiation therapy (3DCRT) and Intensity Modulated Radiation Therapy (IMRT), focusing especially on the doses to organs at risk, such as normal lung and heart tissue. Of the 37 patients, the data from 27 patients were analyzed. Among these 27 patients, four patients (15%) developed grade 2 pericardial effusion as a late toxicity. None of the patients developed grade 3 or worse acute or late pulmonary and cardiac toxicities. When the dosimetric parameters between PBT and planned 3DCRT were compared, all the PBT domestic variables for the lung dose except for lung V10 GyE and V15 GyE were significantly lower than those for the dummy 3DCRT plans, and the PBT domestic variables for the heart dose were also significantly lower than those for the dummy 3DCRT plans. When the PBT and IMRT plans were compared, all the PBT domestic variables for the doses to the lung and heart were significantly lower than those for the dummy IMRT plans. Regarding the correlation between the grades of toxicities and the dosimetric parameters, no significant correlation was seen between the occurrence of grade 2 pericardial effusion and the dose to the heart. When the dosimetric parameters of the dose distributions for the treatment of patients with locally advanced stage III ESCC were compared between PBT and 3DCRT or IMRT, PBT enabled a significant reduction in the dose to the lung and heart, compared with 3DCRT or IMRT.

  1. Prediction of iodine-131 biokinetics and radiation doses from therapy on the basis of tracer studies: an important question for therapy planning in nuclear medicine.

    PubMed

    Willegaignon, José; Pelissoni, Rogério A; Lima, Beatriz C G D; Sapienza, Marcelo T; Coura-Filho, George B; Buchpiguel, Carlos A

    2016-05-01

    This study aimed to present a comparison of iodine-131 (I) biokinetics and radiation doses to red-marrow (rm) and whole-body (wb), following the administration of tracer and therapeutic activities, as a means of confirming whether I clearance and radiation doses for therapy procedures can be predicted by tracer activities. Eleven differentiated thyroid cancer patients were followed after receiving tracer and therapeutic I activity. Whole-body I clearance was estimated using radiation detectors and OLINDA/EXM software was used to calculate radiation doses to rm and wb. Tracer I activity of 86 (±14) MBq and therapeutic activity of 8.04 (±1.18) GBq were administered to patients, thereby producing an average wb I effective half-time and residence time of, respectively, 13.51 (±4.05) and 23.13 (±5.98) h for tracer activities and 13.32 (±3.38) and 19.63 (±4.77) h for therapy. Radiation doses to rm and wb were, respectively, 0.0467 (±0.0208) and 0.0589 (±0.0207) mGy/MBq in tracer studies and 0.0396 (±0.0169) and 0.0500 (±0.0163) mGy/MBq in therapy. Although the differences were not considered statistically significant between averages, those between the values of effective half-times (P=0.906), residence times (P=0.145), and radiation doses to rm (P=0.393) and to wb (P=0.272), from tracer and therapy procedures, large differences of up to 80% in wb I clearance, and up to 50% in radiation doses were observed when patients were analyzed individually, thus impacting on the total amount of I activity calculated to be safe for application in individual therapy. I biokinetics and radiation doses to rm and wb in therapy procedures are well predicted by diagnostic activities when average values of a group of patients are compared. Nonetheless, when patients are analyzed individually, significant differences may be encountered, thus implying that nuclear medicine therapy-planning requires due consideration of changes in individual patient-body status from initial tracer to final therapy procedures to thus provide appropriate adjustments in therapeutic activities.

  2. COBALT 60 KILOCURIE TELETHERAPY ADVANTAGES AND LIMITATIONS--TECHNICAL PROBLEMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patricio, M.B.

    1961-12-01

    The advantages of Co/sup 60/ therapy over conventional x-ray therapy, stemming from the fact that in the lst instance energy absorption within the tissues is by the Compton effect and in the 2nd case by the photoelectric effect, are: (1) increased skin tolerance, (2) reduced bone absorption, (3) increase in depth dose, (4) diminished radiation sickness, and (5) simplicity of operation. As a disadvantage, possibility of injury to adjacent organs is greater with Co/ sup 60/ therapy, since skin reactions, indicative of overdosage with x-ray therapy, may be absent. Some tumors at limited skin depth, such as in the larynx,more » are not amenable to Co/sup 60/ therapy because of the high exit dose. Various technical problems of Co/sup 60/ therapy are discussed, including precise localization of the tumor, calculation of dosage, use of filters to evenly distribute radiation and prevent hot spots, immobilization and positioning of the patient, and direct dosimetry for affirmation of calculated dosage. Favorable results are described in patients with urinary bladder tumors administered l50- to 200-rad daily doses, for a total of 6000 to 8000 rads over 6 to 8 weeks. (H.H.D.)« less

  3. Radioactivity of natural medicinal preparations contained extracts from peat mud available in retail trade used externally.

    PubMed

    Karpińska, Maria; Kapała, Jacek; Raciborska, Agnieszka; Kulesza, Grzegorz; Milewska, Anna; Mnich, Stanisław

    2017-08-01

    In this work were identified and measured the activity of radioactive isotopes present in medicinal preparations from peat mud and estimated the doses obtained from them during therapy. Radioactivity of 22 preparations from peat mud and 20 water samples from water of the North-East region of Poland was studied. The median of the total activity was 24.8 Bq kg -1 . Total maximal isotope activity was observed in the Iwonicka Cube 146 Bq kg -1 while considerable amounts of isotopes were found in the Kolobrzeska Peat Mud Paste 112 Bq kg -1 . The doses obtained during therapy were within the range of 11 nSv-13 μSv depending on extracts of medicinal preparations from peat mud. The probability that such a small dose would stimulate biological effects is low. However, some clinicians believe that one of the possible therapeutic mechanisms in the treatment of rheumatoid disorders is the induction of immune response by ionising radiation.

  4. Predictors of High-Grade Esophagitis after Definitive 3D Conformal Therapy, Intensity Modulated Radiation Therapy, or Proton Beam Therapy for Non-Small Cell Lung Cancer

    PubMed Central

    Gomez, Daniel R.; Tucker, Susan L.; Martel, Mary K.; Mohan, Radhe; Balter, Peter A.; Guerra, Jose Luis Lopez; Liu, Hongmei; Komaki, Ritsuko; Cox, James D.; Liao, Zhongxing

    2014-01-01

    Introduction We analyzed the ability of various patient- and treatment-related factors to predict radiation-induced esophagitis (RE) in patients with non-small cell lung cancer (NSCLC) treated with three-dimensional (3D) conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), or proton beam therapy (PBT). Methods and Materials Patients were treated for NSCLC with 3D-CRT, IMRT, or PBT at MD Anderson from 2000 to 2008 and had full dose-volume histogram (DVH) data available. The endpoint was severe (grade ≥3) RE. The Lyman-Kutcher-Burman (LKB) model was used to analyze RE as a function of the fractional esophageal DVH, with clinical variables included as dose-modifying factors. Results Overall, 652 patients were included: 405 treated with 3D-CRT, 139 with IMRT, and 108 with PBT; corresponding rates of grade ≥3 RE were 8%, 28%, and 6%, with a median time to onset of 42 days (range 11–93 days). A fit of the fractional-DVH LKB model demonstrated that the volume parameter n was significantly different (p=0.046) than 1, indicating that high doses to small volumes are more predictive than mean esophageal dose. The model fit was better for 3D-CRT and PBT than for IMRT. Including receipt of concurrent chemotherapy as a dose-modifying factor significantly improved the LKB model (p=0.005), and the model was further improved by including a variable representing treatment with >30 fractions. Examining individual types of chemotherapy agents revealed a trend toward receipt of concurrent taxanes and increased risk of RE (p=0.105). Conclusions The fractional dose (dose rate) and number of fractions (total dose) distinctly affect the risk of severe RE estimated using the LKB model, and concurrent chemotherapy improves the model fit. This risk of severe RE is underestimated by this model in patients receiving IMRT. PMID:22920974

  5. Phase I Trial of Bortezomib and Concurrent External Beam Radiation in Patients With Advanced Solid Malignancies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pugh, Thomas J.; Chen Changhu; Rabinovitch, Rachel

    Purpose: To determine the maximal tolerated dose of bortezomib with concurrent external beam radiation therapy in patients with incurable solid malignant tumors requiring palliative therapy. Methods and Materials: An open label, dose escalation, phase I clinical trial evaluated the safety of three dose levels of bortezomib administered intravenously (1.0 mg/m{sup 2}, 1.3 mg/m{sup 2}, and 1.6 mg/m{sup 2}/ dose) once weekly with concurrent radiation in patients with histologically confirmed solid tumors and a radiographically appreciable lesion suitable for palliative radiation therapy. All patients received 40 Gy in 16 fractions to the target lesion. Dose-limiting toxicity was the primary endpoint, definedmore » as any grade 4 hematologic toxicity, any grade {>=}3 nonhematologic toxicity, or any toxicity requiring treatment to be delayed for {>=}2 weeks. Results: A total of 12 patients were enrolled. Primary sites included prostate (3 patients), head and neck (3 patients), uterus (1 patient), abdomen (1 patient), breast (1 patient), kidney (1 patient), lung (1 patient), and colon (1 patient). The maximum tolerated dose was not realized with a maximum dose of 1.6 mg/m{sup 2}. One case of dose-limiting toxicity was appreciated (grade 3 urosepsis) and felt to be unrelated to bortezomib. The most common grade 3 toxicity was lymphopenia (10 patients). Common grade 1 to 2 events included nausea (7 patients), infection without neutropenia (6 patients), diarrhea (5 patients), and fatigue (5 patients). Conclusions: The combination of palliative external beam radiation with concurrent weekly bortezomib therapy at a dose of 1.6 mg/m{sup 2} is well tolerated in patients with metastatic solid tumors. The maximum tolerated dose of once weekly bortezomib delivered concurrently with radiation therapy is greater than 1.6 mg/m{sup 2}.« less

  6. Initial results of the use of prescription order change forms to achieve dose form optimization (consolidation and tablet splitting) of SSRI antidepressants in a state Medicaid program.

    PubMed

    Hamer, Ann M; Hartung, Daniel M; Haxby, Dean G; Ketchum, Kathy L; Pollack, David A

    2006-01-01

    One method to reduce drug costs is to promote dose form optimization strategies that take advantage of the flat pricing of some drugs, i.e., the same or nearly the same price for a 100 mg tablet and a 50 mg tablet of the same drug. Dose form optimization includes tablet splitting; taking half of a higher-strength tablet; and dose form consolidation, using 1 higher-strength tablet instead of 2 lower-strength tablets. Dose form optimization can reduce the direct cost of therapy by up to 50% while continuing the same daily dose of the same drug molecule. To determine if voluntary prescription change forms for antidepressant drugs could induce dosing changes and reduce the cost of antidepressant therapy in a Medicaid population. Specific regimens of 4 selective serotonin reuptake inhibitors (SSRIs)- citalopram, escitalopram, paroxetine, and sertraline- were identified for conversion to half tablets or dose optimization. Change forms, which served as valid prescriptions, were faxed to Oregon prescribers in October 2004. The results from both the returned forms and subsequent drug claims data were evaluated using a segmented linear regression. Citalopram claims were excluded from the cost analysis because the drug became available in generic form in October 2004. A total of 1,582 change forms were sent to 556 unique prescribers; 9.2% of the change forms were for dose consolidation and 90.8% were for tablet splitting. Of the 1,118 change forms (70.7%) that were returned, 956 (60.4% of those sent and 85.5% of those returned) authorized a prescription change to a lower-cost dose regimen. The average drug cost per day declined by 14.2%, from Dollars 2.26 to Dollars 1.94 in the intervention group, versus a 1.6% increase, from Dollars 2.52 to Dollars 2.56, in the group without dose consolidation or tablet splitting of the 3 SSRIs (sertraline, escitalopram, and immediate-release paroxetine). Total drug cost for the 3 SSRIs declined by 35.6%, from Dollars 333,567 to Dollars 214,794, as a result of a 24.8% decline in the total days of SSRI drug therapy and the 14.2% decline in average SSRI drug cost per day. The estimated monthly cost avoidance from this intervention, based on pharmacy claims data, was approximately Dollars 35,285, about 2% of the entire spending on SSRI drugs each month, or about Dollars 0.09 per member per month. Program administration costs, excluding costs incurred by prescribers and pharmacy providers, were about 2% of SSRI drug cost savings. Voluntary prescription change forms appear to be an effective and well-accepted tool for obtaining dose form optimization through dose form consolidation and tablet splitting, resulting in reduction in the direct costs of SSRI antidepressant drug therapy with minimal additional program administration costs.

  7. Control of acid and duodenogastroesophageal reflux (DGER) in patients with Barrett's esophagus.

    PubMed

    Yachimski, Patrick; Maqbool, Sabba; Bhat, Yasser M; Richter, Joel E; Falk, Gary W; Vaezi, Michael F

    2015-08-01

    Symptom eradication in patients with Barrett's esophagus (BE) does not guarantee control of acid or duodenogastroesophageal reflux (DGER). Continued reflux of acid and/or DGER may increase risk of neoplastic progression and may decrease the likelihood of columnar mucosa eradication after ablative therapy. To date, no study has addressed whether both complete acid and DGER control is possible in patients with BE. This prospective study was designed to assess the effect of escalating-dose proton pump inhibitor (PPI) therapy on esophageal acid and DGER. Patients with BE (≥3 cm in length) underwent simultaneous ambulatory prolonged pH and DGER monitoring after at least 1 week off PPI therapy followed by testing on therapy after 1 month of twice-daily rabeprazole (20 mg). In those with continued acid and/or DGER, the tests were repeated after 1 month of double-dose (40 mg twice daily) rabeprazole. The primary study outcome was normalization of both acid and DGER. Symptom severity was assessed on and off PPI therapy employing a four-point ordinal scale. A total of 29 patients with BE consented for pH monitoring, of whom 23 also consented for both pH and DGER monitoring off and on therapy (83% male; mean age 58 years; mean body mass index 29; mean Barrett's length 6.0 cm). Median (interquartile range) total % time pH <4 and bilirubin absorbance >0.14 off PPI therapy were 18.4 (11.7-20.0) and 9.7 (5.0-22.2), respectively. In addition, 26/29 (90%) had normalized acid and 18/23 (78%) had normalized DGER on rabeprazole 20 mg. Among those not achieving normalization on 20 mg twice daily, 3/3 (100%) had normalized acid and 4/5 (80%) had normalized DGER on rabeprazole 40 mg twice daily. All subjects had symptoms controlled on rabeprazole 20 mg twice daily. Univariate analysis found no predictor for normalization of physiologic parameters based on demographics. Symptom control does not guarantee normalization of acid and DGER at standard dose of twice-daily PPI therapy. Normalization of acid and DGER can be achieved in 79% of BE patients on rabeprazole 20 mg p.o. twice daily, and in the majority of the remainder at high-dose twice-daily PPI. In patients undergoing ablative therapy, pH or DGER monitoring may not be needed to ensure normalization of reflux if patients are treated with high-dose PPI therapy.

  8. Adherence to phosphate binders in hemodialysis patients: prevalence and determinants.

    PubMed

    Van Camp, Yoleen P M; Vrijens, Bernard; Abraham, Ivo; Van Rompaey, Bart; Elseviers, Monique M

    2014-12-01

    Phosphate control is a crucial treatment goal in end-stage renal disease, but poor patient adherence to phosphate binder therapy remains a challenge. This study aimed to estimate the extent of phosphate binder adherence in hemodialysis patients and to identify potential determinants. Phosphate binder adherence was measured blindly in 135 hemodialysis patients for 2 months using the medication event monitoring system. Patient data, gathered at inclusion through medical records, ad hoc questionnaires and the short form (SF)-36 health survey, included: (1) demographics, (2) perceived side-effects, belief in benefit, self-reported adherence to the therapy, (3) knowledge about phosphate binder therapy, (4) social support, and (5) quality of life (SF-36). Phosphatemia data was collected from charts. 'Being adherent' was defined as missing <1 total daily dose/week and 'being totally adherent' as missing <1 total daily dose/week, every week. Mean age of patients was 67 years and 64 % of the sample was male. Over the 2 months, 78 % of the prescribed doses were taken. Every week, about half of patients were adherent. Over the entire 8-week period, 22 % of patients were totally adherent. Mean phosphatemia levels were 0.55 mg/dl lower in adherent than nonadherent patients (4.76 vs. 5.31 mg/dl). Determinants for being totally adherent were living with a partner, higher social support (both were interrelated) and higher physical quality of life. Experiencing intake-related inconvenience negatively affected adherence. The social support and quality of life physical score explained 26 % of the variance in adherence. Phosphate binder nonadherence remains a major problem. Interventions should aim, at least, to improve social support. With few associated factors found and yet low adherence, an individualized approach seems indicated.

  9. Impact of bowel gas and body outline variations on total accumulated dose with intensity-modulated proton therapy in locally advanced cervical cancer patients.

    PubMed

    Berger, Thomas; Petersen, Jørgen Breede Baltzer; Lindegaard, Jacob Christian; Fokdal, Lars Ulrik; Tanderup, Kari

    2017-11-01

    Density changes occurring during fractionated radiotherapy in the pelvic region may degrade proton dose distributions. The aim of the study was to quantify the dosimetric impact of gas cavities and body outline variations. Seven patients with locally advanced cervical cancer (LACC) were analyzed through a total of 175 daily cone beam computed tomography (CBCT) scans. Four-beams intensity-modulated proton therapy (IMPT) dose plans were generated targeting the internal target volume (ITV) composed of: primary tumor, elective and pathological nodes. The planned dose was 45 Gy [Relative-Biological-Effectiveness-weighted (RBE)] in 25 fractions and simultaneously integrated boosts of pathologic lymph nodes were 55-57.5 Gy (RBE). In total, 475 modified CTs were generated to evaluate the effect of: 1/gas cavities, 2/outline variations and 3/the two combined. The anatomy of each fraction was simulated by propagating gas cavities contours and body outlines from each daily CBCT to the pCT. Hounsfield units corresponding to gas and fat were assigned to the propagated contours. D98 (least dose received by the hottest 98% of the volume) and D99.9 for targets and V43Gy(RBE) (volume receiving ≥43 Gy(RBE)) for organs at risk (OARs) were recalculated on each modified CT, and total dose was evaluated through dose volume histogram (DVH) addition across all fractions. Weight changes during radiotherapy were between -3.1% and 1.2%. Gas cavities and outline variations induced a median [range] dose degradation for ITV45 of 1.0% [0.5-3.5%] for D98 and 2.1% [0.8-6.4%] for D99.9. Outline variations had larger dosimetric impact than gas cavities. Worst nodal dose degradation was 2.0% for D98 and 2.3% for D99.9. The impact on bladder, bowel and rectum was limited with V43Gy(RBE) variations ≤3.5 cm 3 . Bowel gas cavities and outline variations had minor impact on accumulated dose in targets and OAR of four-field IMPT in a LACC population of moderate weight changes.

  10. 131I-tositumomab myeloablative radioimmunotherapy for non-Hodgkin’s lymphoma: radiation dose to the testes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hattori, Naoya; Gopal, Ajay K.; Shields, Andrew T.

    Purpose: To investigate radiation doses to the testes delivered by a radiolabeled anti-CD20 antibody and its effects on male sex hormone levels. Materials and methods: Testicular uptake and retention of 131I-tositumomab were measured, and testicular absorbed doses were calculated for 67 male patients (54+/-11 years of age) with non-Hodgkin's lymphoma who had undergone myeloablative radioimmunotherapy (RIT) using 131I-tositumomab. Time-activity curves for the major organs, testes, and whole body were generated from planar imaging studies. In a subset of patients, male sex hormones were measured before and 1 year after the therapy. Results: The absorbed dose to the testes showed considerablemore » variability (range=4.4-70.2 Gy). Pretherapy levels of total testosterone were below the lower limit of the reference range, and post-therapy evaluation demonstrated further reduction [4.6+/-1.8 nmol/l (pre-RIT) vs. 3.8+/-2.9 nmol/l (post-RIT), P<0.05]. Patients receiving higher radiation doses to the testes (>=25 Gy) showed a greater reduction [4.7+/-1.6 nmol/l (pre-RIT) vs. 3.3+/-2.7 nmol/l (post-RIT), P<0.05] compared with patients receiving lower doses (<25 Gy), who showed no significant change in total testosterone levels. Conclusion: The testicular radiation absorbed dose varied highly among individual patients. Finally, patients receiving higher doses to the testes were more likely to show post-RIT suppression of testosterone levels.« less

  11. A simple and fast physics-based analytical method to calculate therapeutic and stray doses from external beam, megavoltage x-ray therapy

    PubMed Central

    Wilson, Lydia J; Newhauser, Wayne D

    2015-01-01

    State-of-the-art radiotherapy treatment planning systems provide reliable estimates of the therapeutic radiation but are known to underestimate or neglect the stray radiation exposures. Most commonly, stray radiation exposures are reconstructed using empirical formulas or lookup tables. The purpose of this study was to develop the basic physics of a model capable of calculating the total absorbed dose both inside and outside of the therapeutic radiation beam for external beam photon therapy. The model was developed using measurements of total absorbed dose in a water-box phantom from a 6 MV medical linear accelerator to calculate dose profiles in both the in-plane and cross-plane direction for a variety of square field sizes and depths in water. The water-box phantom facilitated development of the basic physical aspects of the model. RMS discrepancies between measured and calculated total absorbed dose values in water were less than 9.3% for all fields studied. Computation times for 10 million dose points within a homogeneous phantom were approximately 4 minutes. These results suggest that the basic physics of the model are sufficiently simple, fast, and accurate to serve as a foundation for a variety of clinical and research applications, some of which may require that the model be extended or simplified based on the needs of the user. A potentially important advantage of a physics-based approach is that the model is more readily adaptable to a wide variety of treatment units and treatment techniques than with empirical models. PMID:26040833

  12. A simple and fast physics-based analytical method to calculate therapeutic and stray doses from external beam, megavoltage x-ray therapy.

    PubMed

    Jagetic, Lydia J; Newhauser, Wayne D

    2015-06-21

    State-of-the-art radiotherapy treatment planning systems provide reliable estimates of the therapeutic radiation but are known to underestimate or neglect the stray radiation exposures. Most commonly, stray radiation exposures are reconstructed using empirical formulas or lookup tables. The purpose of this study was to develop the basic physics of a model capable of calculating the total absorbed dose both inside and outside of the therapeutic radiation beam for external beam photon therapy. The model was developed using measurements of total absorbed dose in a water-box phantom from a 6 MV medical linear accelerator to calculate dose profiles in both the in-plane and cross-plane direction for a variety of square field sizes and depths in water. The water-box phantom facilitated development of the basic physical aspects of the model. RMS discrepancies between measured and calculated total absorbed dose values in water were less than 9.3% for all fields studied. Computation times for 10 million dose points within a homogeneous phantom were approximately 4 min. These results suggest that the basic physics of the model are sufficiently simple, fast, and accurate to serve as a foundation for a variety of clinical and research applications, some of which may require that the model be extended or simplified based on the needs of the user. A potentially important advantage of a physics-based approach is that the model is more readily adaptable to a wide variety of treatment units and treatment techniques than with empirical models.

  13. Uncertainty analysis of absorbed dose calculations from thermoluminescence dosimeters.

    PubMed

    Kirby, T H; Hanson, W F; Johnston, D A

    1992-01-01

    Thermoluminescence dosimeters (TLD) are widely used to verify absorbed doses delivered from radiation therapy beams. Specifically, they are used by the Radiological Physics Center for mailed dosimetry for verification of therapy machine output. The effects of the random experimental uncertainties of various factors on dose calculations from TLD signals are examined, including: fading, dose response nonlinearity, and energy response corrections; reproducibility of TL signal measurements and TLD reader calibration. Individual uncertainties are combined to estimate the total uncertainty due to random fluctuations. The Radiological Physics Center's (RPC) mail out TLD system, utilizing throwaway LiF powder to monitor high-energy photon and electron beam outputs, is analyzed in detail. The technique may also be applicable to other TLD systems. It is shown that statements of +/- 2% dose uncertainty and +/- 5% action criterion for TLD dosimetry are reasonable when related to uncertainties in the dose calculations, provided the standard deviation (s.d.) of TL readings is 1.5% or better.

  14. Cisplatin, Gemcitabine, and Lapatinib as Neoadjuvant Therapy for Muscle-Invasive Bladder Cancer.

    PubMed

    Narayan, Vivek; Mamtani, Ronac; Keefe, Stephen; Guzzo, Thomas; Malkowicz, S Bruce; Vaughn, David J

    2016-07-01

    We sought to investigate the safety and efficacy of gemcitabine, cisplatin, and lapatinib (GCL) as neoadjuvant therapy in patients with muscle-invasive bladder cancer (MIBC) planned for radical cystectomy. Four cycles of GCL were administered as neoadjuvant therapy for patients with MIBC. Although initially designed as a phase II efficacy study with a primary endpoint of pathologic complete response at the time of radical cystectomy, the dose selected for investigation proved excessively toxic. A total of six patients were enrolled. The initial four patients received gemcitabine 1,000 mg/m(2) intravenously on days 1 and 8 and cisplatin 70 mg/m(2) intravenously on day 1 of each 21-day treatment cycle. Lapatinib was administered as 1,000 mg orally daily starting one week prior to the initiation of cycle 1 of gemcitabine and cisplatin (GC) and continuing until the completion of cycle 4 of GC. These initial doses were poorly tolerated, and the final two enrolled patients received a reduced lapatinib dose of 750 mg orally daily. However, reduction of the lapatinib dose did not result in improved tolerance or drug-delivery, and the trial was terminated early due to excessive toxicity. Grade 3/4 toxicities included diarrhea (33%), nausea/vomiting (33%), and thrombocytopenia (33%). The addition of lapatinib to GC as neoadjuvant therapy for MIBC was limited by excessive treatment-related toxicity. These findings highlight the importance of thorough dose-escalation investigation of combination therapies prior to evaluation in the neoadjuvant setting, as well as the limitations of determination of maximum tolerated dose for novel targeted combination regimens.

  15. Comparison of doses received by the hippocampus in patients treated with single isocenter- vs multiple isocenter-based stereotactic radiation therapy to the brain for multiple brain metastases.

    PubMed

    Algan, Ozer; Giem, Jared; Young, Julie; Ali, Imad; Ahmad, Salahuddin; Hossain, Sabbir

    2015-01-01

    To investigate the doses received by the hippocampus and normal brain tissue during a course of stereotactic radiation therapy using a single isocenter (SI)-based or multiple isocenter (MI)-based treatment planning in patients with less than 4 brain metastases. In total, 10 patients with magnetic resonance imaging (MRI) demonstrating 2-3 brain metastases were included in this retrospective study, and 2 sets of stereotactic intensity-modulated radiation therapy (IMRT) treatment plans (SI vs MI) were generated. The hippocampus was contoured on SPGR sequences, and doses received by the hippocampus and the brain were calculated and compared between the 2 treatment techniques. A total of 23 lesions in 10 patients were evaluated. The median tumor volume, the right hippocampus volume, and the left hippocampus volume were 3.15, 3.24, and 2.63mL, respectively. In comparing the 2 treatment plans, there was no difference in the planning target volume (PTV) coverage except in the tail for the dose-volume histogram (DVH) curve. The only statistically significant dosimetric parameter was the V100. All of the other measured dosimetric parameters including the V95, V99, and D100 were not significantly different between the 2 treatment planning techniques. None of the dosimetric parameters evaluated for the hippocampus revealed any statistically significant difference between the MI and SI plans. The total brain doses were slightly higher in the SI plans, especially in the lower dose region, although this difference was not statistically different. The use of SI-based treatment plan resulted in a 35% reduction in beam-on time. The use of SI treatments for patients with up to 3 brain metastases produces similar PTV coverage and similar normal tissue doses to the hippocampus and the brain when compared with MI plans. SI treatment planning should be considered in patients with multiple brain metastases undergoing stereotactic treatment. Copyright © 2015 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  16. Outpatient radioiodine therapy for thyroid cancer: a safe nuclear medicine procedure.

    PubMed

    Willegaignon, José; Sapienza, Marcelo; Ono, Carla; Watanabe, Tomoco; Guimarães, Maria Inês; Gutterres, Ricardo; Marechal, Maria Helena; Buchpiguel, Carlos

    2011-06-01

    To evaluate the dosimetric effect of outpatient radioiodine therapy for thyroid cancer in members of a patient's family and their living environment, when using iodine-131 doses reaching 7.4 GBq. The following parameters were thus defined: (a) whole-body radiation doses to caregivers, (b) the production of contaminated solid waste, and (c) radiation potential and surface contamination within patients' living quarters. In total, 100 patients were treated on an outpatient basis, taking into consideration their acceptable living conditions, interests, and willingness to comply with medical and radiation safety guidelines. Both the caregivers and the radiation dose potentiality inside patients' residences were monitored by using thermoluminescent dosimeters. Surface contamination and contaminated solid wastes were identified and measured with a Geiger-Müller detector. A total of 90 monitored individuals received a mean dose of 0.27 (±0.28) mSv, and the maximum dose registered was 1.6 mSv. The mean value for the potential dose within all living quarters was 0.31 (±0.34) mSv, and the mean value per monitored surface was 5.58 Bq/cm(2) for all the 1659 points measured. The overall production of contaminated solid wastes was at a low level, being about 3 times less than the exemption level indicated by the International Atomic Energy Agency. This study indicates that the treatment of thyroid cancer by applying radioiodine activities up to 7.4 GBq, on an outpatient basis, is a safe procedure, especially when supervised by qualified professionals. This alternative therapy should be a topic for careful discussion considering the high potential for reducing costs in healthcare and improving patient acceptance.

  17. Cost-effectiveness analysis of hypertension treatment: controlled release nifedipine and candesartan low-dose combination therapy in patients with essential hypertension--the Nifedipine and Candesartan Combination (NICE-Combi) Study.

    PubMed

    Fujikawa, Keita; Hasebe, Naoyuki; Kikuchi, Kenjiro

    2005-07-01

    Societal interest in pharmaco-economic analysis is increasing in Japan. In this study, the cost-effectiveness of low-dose combination therapy with controlled release nifedipine plus candesartan and up-titrated monotherapy with candesartan was estimated, based on the results of the NICE-Combi study. The NICE-Combi study was a double-blind, parallel arm, randomized clinical trial to compare the efficacy of low-dose combination therapy of controlled release nifedipine (20 mg/day) plus candesartan (8 mg/day) vs. up-titrated monotherapy of candesartan (12 mg/day) on blood pressure control in Japanese patients with mild to severe essential hypertension who were not sufficiently controlled by the conventional dose of candesartan (8 mg/ day). The incremental cost effectiveness of each cohort during the 8-week randomization period was compared, from the perspective of a third-party payer (i.e., insurers). The average total cost per patient was 29,943 Japanese yen for the combination therapy group and 33,182 Japanese yen for the candesartan monotherapy group, while the rate of achievement of the target blood pressure was significantly higher in the combination therapy group than in the up-titrated monotherapy group. In the combination therapy group, higher efficacy and lower incremental treatment cost ("Dominance") were observed when compared to the monotherapy group. The sensitivity analyses also supported the results. In conclusion, these results suggest that combination therapy with controlled release nifedipine and low-dose candesartan (8 mg) is "dominant" to up-titrated candesartan monotherapy for the management of essential hypertension. This conclusion was robust to sensitivity analysis.

  18. Comparison of 10 efficient protocols for photodynamic therapy of actinic keratosis: How relevant are effective light dose and local damage in predicting the complete response rate at 3 months?

    PubMed

    Vignion-Dewalle, Anne-Sophie; Baert, Gregory; Thecua, Elise; Lecomte, Fabienne; Vicentini, Claire; Abi-Rached, Henry; Mortier, Laurent; Mordon, Serge

    2018-04-18

    Topical photodynamic therapy is an established treatment modality for various dermatological conditions, including actinic keratosis. In Europe, the approved protocols for photodynamic therapy of actinic keratosis involve irradiation with either an Aktilite CL 128 lamp or daylight, whereas irradiation with the Blu-U illuminator is approved in the United States. Many other protocols using irradiation by a variety of light sources are also clinically efficient. This paper aims to compare 10 different protocols with clinically proven efficacy for photodynamic therapy of actinic keratosis and the available spectral irradiance of the light source. Effective irradiance, effective light dose, and local damage are compared. We also investigate whether there is an association between the complete response rate at 3 months and the effective light dose or local damage. The effective irradiance, also referred to as protoporphyrin IX-weighted irradiance, is obtained by integrating the spectral irradiance weighted by the normalized absorption spectrum of protoporphyrin IX over the wavelength. Integrating the effective irradiance over the irradiation time yields the effective light dose, which is also known as the protoporphyrin IX-weighted light dose. Local damage, defined as the total cumulative singlet oxygen molecules produced during treatment, is estimated using mathematical modeling of the photodynamic therapy process. This modeling is based on an iterative procedure taking into account the spatial and temporal variations in the protoporphyrin IX absorption spectrum during treatment. The protocol for daylight photodynamic therapy on a clear sunny day, the protocol for daylight photodynamic therapy on an overcast day, the photodynamic therapy protocol for a white LED lamp for operating rooms and the photodynamic therapy protocol for the Blu-U illuminator perform better than the six other protocols-all involving red light illumination-in terms of both effective light dose and local damage. However, no association between the complete response rate at 3 months and the effective light dose or local damage was found. Protocols that achieve high complete response rates at 3 months and low pain scores should be preferred regardless of the effective light dose and local damage. Lasers Surg. Med. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  19. Changes in circulating IGF1 receptor stimulating activity do not parallel changes in total IGF1 during GH treatment of GH-deficient adults.

    PubMed

    Varewijck, Aimee J; Lamberts, Steven W J; van der Lely, A J; Neggers, Sebastian J C M M; Hofland, Leo J; Janssen, Joseph A M J L

    2015-08-01

    Previously we demonstrated that IGF1 receptor stimulating activity (IGF1RSA) offers advantages in diagnostic evaluation of adult GH deficiency (GHD). It is unknown whether IGF1RSA can be used to monitor GH therapy. To investigate the value of circulating IGF1RSA for monitoring GH therapy. 106 patients (54 m; 52 f) diagnosed with GHD were included; 22 were GH-naïve, 84 were already on GH treatment and discontinued therapy 4 weeks before baseline values were established. IGF1RSA was determined by the IGF1R kinase receptor activating assay, total IGF1 by immunoassay (Immulite). GH doses were titrated to achieve total IGF1 levels within the normal range. After 12 months, total IGF1 and IGF1RSA increased significantly (total IGF1 from 8.1 (95% CI 7.3-8.9) to 14.9 (95% CI 13.5-16.4) nmol/l and IGF1RSA from 115 (95% CI 104-127) to 181 (95% CI 162-202) pmol/l). After 12 months, total IGF1 normalized in 81% of patients, IGF1RSA in 51% and remained below normal in more than 40% of patients in whom total IGF1 had normalized. During 12 months of GH treatment, changes in IGF1RSA did not parallel changes in total IGF1. Despite normalization of total IGF1, IGF1RSA remained subnormal in a considerable proportion of patients. At present our results have no short-term consequences for GH therapy of GHD patients. However, based on our findings we propose future studies to examine whether titrating GH dose against IGF1RSA results in a better clinical outcome than titrating against total IGF1. © 2015 European Society of Endocrinology.

  20. Time-gated scintillator imaging for real-time optical surface dosimetry in total skin electron therapy.

    PubMed

    Bruza, Petr; Gollub, Sarah L; Andreozzi, Jacqueline M; Tendler, Irwin I; Williams, Benjamin B; Jarvis, Lesley A; Gladstone, David J; Pogue, Brian W

    2018-05-02

    The purpose of this study was to measure surface dose by remote time-gated imaging of plastic scintillators. A novel technique for time-gated, intensified camera imaging of scintillator emission was demonstrated, and key parameters influencing the signal were analyzed, including distance, angle and thickness. A set of scintillator samples was calibrated by using thermo-luminescence detector response as reference. Examples of use in total skin electron therapy are described. The data showed excellent room light rejection (signal-to-noise ratio of scintillation SNR  ≈  470), ideal scintillation dose response linearity, and 2% dose rate error. Individual sample scintillation response varied by 7% due to sample preparation. Inverse square distance dependence correction and lens throughput error (8% per meter) correction were needed. At scintillator-to-source angle and observation angle  <50°, the radiant energy fluence error was smaller than 1%. The achieved standard error of the scintillator cumulative dose measurement compared to the TLD dose was 5%. The results from this proof-of-concept study documented the first use of small scintillator targets for remote surface dosimetry in ambient room lighting. The measured dose accuracy renders our method to be comparable to thermo-luminescent detector dosimetry, with the ultimate realization of accuracy likely to be better than shown here. Once optimized, this approach to remote dosimetry may substantially reduce the time and effort required for surface dosimetry.

  1. Time-gated scintillator imaging for real-time optical surface dosimetry in total skin electron therapy

    NASA Astrophysics Data System (ADS)

    Bruza, Petr; Gollub, Sarah L.; Andreozzi, Jacqueline M.; Tendler, Irwin I.; Williams, Benjamin B.; Jarvis, Lesley A.; Gladstone, David J.; Pogue, Brian W.

    2018-05-01

    The purpose of this study was to measure surface dose by remote time-gated imaging of plastic scintillators. A novel technique for time-gated, intensified camera imaging of scintillator emission was demonstrated, and key parameters influencing the signal were analyzed, including distance, angle and thickness. A set of scintillator samples was calibrated by using thermo-luminescence detector response as reference. Examples of use in total skin electron therapy are described. The data showed excellent room light rejection (signal-to-noise ratio of scintillation SNR  ≈  470), ideal scintillation dose response linearity, and 2% dose rate error. Individual sample scintillation response varied by 7% due to sample preparation. Inverse square distance dependence correction and lens throughput error (8% per meter) correction were needed. At scintillator-to-source angle and observation angle  <50°, the radiant energy fluence error was smaller than 1%. The achieved standard error of the scintillator cumulative dose measurement compared to the TLD dose was 5%. The results from this proof-of-concept study documented the first use of small scintillator targets for remote surface dosimetry in ambient room lighting. The measured dose accuracy renders our method to be comparable to thermo-luminescent detector dosimetry, with the ultimate realization of accuracy likely to be better than shown here. Once optimized, this approach to remote dosimetry may substantially reduce the time and effort required for surface dosimetry.

  2. Red marrow and blood dosimetry in 131I treatment of metastatic thyroid carcinoma: pre-treatment versus in-therapy results

    NASA Astrophysics Data System (ADS)

    Giostra, A.; Richetta, E.; Pasquino, M.; Miranti, A.; Cutaia, C.; Brusasco, G.; Pellerito, R. E.; Stasi, M.

    2016-06-01

    Treatment with radioiodine is a standard procedure for patients with well-differentiated thyroid cancer, but the main approach to the therapy is still empiric, consisting of the administration of fixed activities. A predictive individualized dosimetric study may represent an important tool for physicians to determine the best activity to prescribe. The aim of this work is to compare red marrow and blood absorbed dose values obtained in the pre-treatment (PT) dosimetry phase with those obtained in the in-treatment (IT) dosimetry phase in order to estimate the predictive power of PT trial doses and to determine if they can be used as a decision-making tool to safely administer higher 131I activity to potentially increase the efficacy of treatment. The PT and IT dosimetry for 50 patients has been evaluated using three different dosimetric approaches. In all three approaches blood and red marrow doses, are calculated as the sum of two components, the dose from 131I activity in the blood and the dose from 131I activity located in the remainder of the body (i.e. the blood and whole-body contributions to the total dose). PT and IT dose values to blood and red marrow appear to be well correlated irrespective of the dosimetric approach used. Linear regression analyses of PT and IT total doses, for blood and red marrow, and the whole-body contribution to these doses, showed consistent best fit slope and correlation coefficient values of approximately 0.9 and 0.6, respectively: analyses of the blood dose contribution to the total doses also yielded similar values for the best fit slope but with correlation coefficient values of approximately 0.4 reflecting the greater variance in these dose estimates. These findings suggest that pre-treatment red marrow dose assessments may represent an important tool to personalize metastatic thyroid cancer treatment, removing the constraints of a fixed activity approach and permitting potentially more effective higher 131I activities to be safely used in-treatment.

  3. Dosimetric evaluation of a MOSFET detector for clinical application in photon therapy.

    PubMed

    Kohno, Ryosuke; Hirano, Eriko; Nishio, Teiji; Miyagishi, Tomoko; Goka, Tomonori; Kawashima, Mitsuhiko; Ogino, Takashi

    2008-01-01

    Dosimetric characteristics of a metal oxide-silicon semiconductor field effect transistor (MOSFET) detector are studied with megavoltage photon beams for patient dose verification. The major advantages of this detector are its size, which makes it a point dosimeter, and its ease of use. In order to use the MOSFET detector for dose verification of intensity-modulated radiation therapy (IMRT) and in-vivo dosimetry for radiation therapy, we need to evaluate the dosimetric properties of the MOSFET detector. Therefore, we investigated the reproducibility, dose-rate effect, accumulated-dose effect, angular dependence, and accuracy in tissue-maximum ratio measurements. Then, as it takes about 20 min in actual IMRT for the patient, we evaluated fading effect of MOSFET response. When the MOSFETs were read-out 20 min after irradiation, we observed a fading effect of 0.9% with 0.9% standard error of the mean. Further, we applied the MOSFET to the measurement of small field total scatter factor. The MOSFET for dose measurements of small field sizes was better than the reference pinpoint chamber with vertical direction. In conclusion, we assessed the accuracy, reliability, and usefulness of the MOSFET detector in clinical applications such as pinpoint absolute dosimetry for small fields.

  4. Busulfan Injection

    MedlinePlus

    ... marrow and cancer cells in preparation for a bone marrow transplant. Busulfan is in a class of medications called ... days (for a total of 16 doses) before bone marrow transplant.Busulfan injection may cause seizures during therapy with ...

  5. An automated voxelized dosimetry tool for radionuclide therapy based on serial quantitative SPECT/CT imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jackson, Price A.; Kron, Tomas; Beauregard, Jean-Mathieu

    2013-11-15

    Purpose: To create an accurate map of the distribution of radiation dose deposition in healthy and target tissues during radionuclide therapy.Methods: Serial quantitative SPECT/CT images were acquired at 4, 24, and 72 h for 28 {sup 177}Lu-octreotate peptide receptor radionuclide therapy (PRRT) administrations in 17 patients with advanced neuroendocrine tumors. Deformable image registration was combined with an in-house programming algorithm to interpolate pharmacokinetic uptake and clearance at a voxel level. The resultant cumulated activity image series are comprised of values representing the total number of decays within each voxel's volume. For PRRT, cumulated activity was translated to absorbed dose basedmore » on Monte Carlo-determined voxel S-values at a combination of long and short ranges. These dosimetric image sets were compared for mean radiation absorbed dose to at-risk organs using a conventional MIRD protocol (OLINDA 1.1).Results: Absorbed dose values to solid organs (liver, kidneys, and spleen) were within 10% using both techniques. Dose estimates to marrow were greater using the voxelized protocol, attributed to the software incorporating crossfire effect from nearby tumor volumes.Conclusions: The technique presented offers an efficient, automated tool for PRRT dosimetry based on serial post-therapy imaging. Following retrospective analysis, this method of high-resolution dosimetry may allow physicians to prescribe activity based on required dose to tumor volume or radiation limits to healthy tissue in individual patients.« less

  6. Osteoradionecrosis of the jaws: a retrospective study of the background factors and treatment in 104 cases.

    PubMed

    Curi, M M; Dib, L L

    1997-06-01

    This study analyzed potential risk factors in patients who received radiation therapy and then developed osteoradionecrosis (ORN). A group of 104 patients who developed osteoradionecrosis of the jaws were reviewed treated between 1972 and 1992. The most common affected site was the mandible (99 cases, 95.2%), followed by the maxilla (5 cases, 4.8%). Among all cases, 93 (89.4%) were induced-trauma ORN, and 11 (10.6%) were spontaneous ORN. The following risk factors were considered as predisposing factors for the appearance of ORN: Anatomic location of the tumor, tumor surgery, total radiation dose, dose rate/day, mode of radiation delivery, time from radiation therapy until the onset of ORN, and dental status. ORN developed more frequently with oral cancer than other head and neck cancers. The size of the tumor seemed not to influence the incidence of ORN except when the tumor invade the adjacent bone. Type of radiation delivery total bone dose, and modes of radiation appeared to influence the risk of ORN occurrence. After conservative treatment, 44 (42.3%) cases had complete healing and resolution 34 (32.6%) cases had a stable, chronic ORN process, and 26 (25.1%) cases had acute and progressive ORN. An understanding of the risk factors is important in preventing ORN after radiation therapy.

  7. Pencil beam scanning proton therapy vs rotational arc radiation therapy: A treatment planning comparison for postoperative oropharyngeal cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Apinorasethkul, Ontida, E-mail: Ontida.a@gmail.com; Kirk, Maura; Teo, Kevin

    Patients diagnosed with head and neck cancer are traditionally treated with photon radiotherapy. Proton therapy is currently being used clinically and may potentially reduce treatment-related toxicities by minimizing the dose to normal organs in the treatment of postoperative oropharyngeal cancer. The finite range of protons has the potential to significantly reduce normal tissue toxicity compared to photon radiotherapy. Seven patients were planned with both proton and photon modalities. The planning goal for both modalities was achieving the prescribed dose to 95% of the planning target volume (PTV). Dose-volume histograms were compared in which all cases met the target coverage goals.more » Mean doses were significantly lower in the proton plans for the oral cavity (1771 cGy photon vs 293 cGy proton, p < 0.001), contralateral parotid (1796 cGy photon vs 1358 proton, p < 0.001), and the contralateral submandibular gland (3608 cGy photon vs 3251 cGy proton, p = 0.03). Average total integral dose was 9.1% lower in proton plans. The significant dosimetric sparing seen with proton therapy may lead to reduced side effects such as pain, weight loss, taste changes, and dry mouth. Prospective comparisons of protons vs photons for disease control, toxicity, and patient-reported outcomes are therefore warranted and currently being pursued.« less

  8. Patterns of brachytherapy practice for patients with carcinoma of the cervix (1996-1999): a patterns of care study.

    PubMed

    Erickson, Beth; Eifel, Patricia; Moughan, Jennifer; Rownd, Jason; Iarocci, Thomas; Owen, Jean

    2005-11-15

    To analyze the details of brachytherapy practice in patients treated for carcinoma of the cervix in the United States between 1996 and 1999. Radiation facilities were selected from a stratified random sample. Patients were randomly selected from lists of eligible patients treated at each facility. A total of 442 patients' records were reviewed in 59 facilities to obtain data about patients' characteristics, evaluation, tumor extent, and treatment. National estimates were made using weights that reflected the relative contribution of each institution and of each patient within the sampled institutions. From our survey we estimate that 16,375 patients were treated in the United States during this study period. Unless otherwise specified, brachytherapy practice was based on the 408 patients who had their brachytherapy or all their treatment at the surveyed facility. A total of 91.5% of patients underwent brachytherapy at the initial treating institution; 8.5% were referred to a second site for brachytherapy. Forty-two percent of U.S. facilities referred at least some patients to a second facility for brachytherapy. Of U.S. facilities that treated < or =2 eligible patients per year, 61% referred all of their patients to a second facility for brachytherapy or treated with external RT alone; none of the U.S. facilities with larger experience (>2 eligible patients per year) referred all their patients to a second facility for brachytherapy treatment, but 28% referred some patients to an outside facility for brachytherapy. Overall, 94% of patients who completed treatment with curative intent received brachytherapy. Of these patients who had brachytherapy, 77.8%, 13.3%, and 0.9%, respectively, were treated with low-dose-rate (LDR), high-dose-rate (HDR), or a combination of HDR and LDR brachytherapy; 7.9% had interstitial brachytherapy (5.7% LDR and 1.9% HDR, 0.3% mixed). In facilities that treated >2 patients per year, 15.5% and 9.4% of brachytherapy procedures included HDR or interstitial, respectively; in facilities that treated fewer patients, 3.4% had HDR brachytherapy, and only 1.2% had interstitial brachytherapy. Patients treated with LDR intracavitary radiotherapy had one (23.5%), two (74.1%), or three (2.4%) implants. For patients treated with curative intent who completed radiation therapy with LDR intracavitary radiation therapy without hysterectomy, the median brachytherapy dose to Point A was 40.3 Gy, and the median total dose to Point A was 82.9 Gy. Patients were treated with HDR intracavitary radiation therapy using a variety of treatment schedules using 1-2 fractions (7.5%), 3-4 fractions (17.4%), 5-6 fractions (38.5%), 7-9 fractions (33.5%), or 12 fractions (3%). Fraction sizes were <500 cGy (29.5%), 500-<600 (25.2%), 600 (28.1%), >600 (8%), or unknown (9.2%). For patients treated with HDR, the median total dose to Point A (corrected for fraction size using a alpha/beta = 10) was 85.8 Gy (range: 56.2-116.1 Gy). At institutions treating <500 new patients per year, the percentage of patients receiving a brachytherapy dose <40 Gy was significantly higher than at institutions treating > or =500 new patients per year (p < 0.0001). For LDR intracavitary radiation therapy, 5.8% had neither bladder nor rectal doses recorded for any of their implants, whereas in HDR intracavitary radiation therapy, 73.4% had neither bladder nor rectal doses recorded for any of their implants. The median total duration of radiation therapy was identical for patients who had HDR or LDR intracavitary radiation therapy (57 days). For LDR at institutions treating <500 new patients per year, the percentage of patients with treatment duration >56 days was significantly greater than at institutions > or =500 new patients per year (p = 0.002). Of the patients who had LDR intracavitary radiation therapy implants, 65% were treated using tandem and shielded Fletcher-Suit-Delclos colpostats; other patients had mini ovoids (10.9%), cylinders (3.9%), Henschke (3.7%), or other/mixed applicators (16.5%). In contrast, of patients treated with HDR intracavitary radiation therapy, 68.7% had tandem and rings, 18.2% Fletcher-Suit-Delclos ovoids, 7.5% mini ovoids, 2.3% cylinders, and 3.2% other or mixed applicators. The median duration of treatment and median Point A dose were very similar for patients treated with HDR or LDR. Patients with HDR were treated using a variety of treatment schedules. Different applicator types were favored for LDR vs. HDR. Of patients treated with HDR, 73.4% had no brachytherapy bladder or rectal doses recorded, suggesting that full dosimetric calculations were performed only for the first fraction in many institutions. Facility size significantly impacted on referral to another institution for brachytherapy, brachytherapy dose, and treatment duration.

  9. Upfront Genotyping of DPYD*2A to Individualize Fluoropyrimidine Therapy: A Safety and Cost Analysis.

    PubMed

    Deenen, Maarten J; Meulendijks, Didier; Cats, Annemieke; Sechterberger, Marjolein K; Severens, Johan L; Boot, Henk; Smits, Paul H; Rosing, Hilde; Mandigers, Caroline M P W; Soesan, Marcel; Beijnen, Jos H; Schellens, Jan H M

    2016-01-20

    Fluoropyrimidines are frequently prescribed anticancer drugs. A polymorphism in the fluoropyrimidine metabolizing enzyme dihydropyrimidine dehydrogenase (DPD; ie, DPYD*2A) is strongly associated with fluoropyrimidine-induced severe and life-threatening toxicity. This study determined the feasibility, safety, and cost of DPYD*2A genotype-guided dosing. Patients intended to be treated with fluoropyrimidine-based chemotherapy were prospectively genotyped for DPYD*2A before start of therapy. Variant allele carriers received an initial dose reduction of ≥ 50% followed by dose titration based on tolerance. Toxicity was the primary end point and was compared with historical controls (ie, DPYD*2A variant allele carriers receiving standard dose described in literature) and with DPYD*2A wild-type patients treated with the standard dose in this study. Secondary end points included a model-based cost analysis, as well as pharmacokinetic and DPD enzyme activity analyses. A total of 2,038 patients were prospectively screened for DPYD*2A, of whom 22 (1.1%) were heterozygous polymorphic. DPYD*2A variant allele carriers were treated with a median dose-intensity of 48% (range, 17% to 91%). The risk of grade ≥ 3 toxicity was thereby significantly reduced from 73% (95% CI, 58% to 85%) in historical controls (n = 48) to 28% (95% CI, 10% to 53%) by genotype-guided dosing (P < .001); drug-induced death was reduced from 10% to 0%. Adequate treatment of genotype-guided dosing was further demonstrated by a similar incidence of grade ≥ 3 toxicity compared with wild-type patients receiving the standard dose (23%; P = .64) and by similar systemic fluorouracil (active drug) exposure. Furthermore, average total treatment cost per patient was lower for screening (€2,772 [$3,767]) than for nonscreening (€2,817 [$3,828]), outweighing screening costs. DPYD*2A is strongly associated with fluoropyrimidine-induced severe and life-threatening toxicity. DPYD*2A genotype-guided dosing results in adequate systemic drug exposure and significantly improves safety of fluoropyrimidine therapy for the individual patient. On a population level, upfront genotyping seemed cost saving. © 2015 by American Society of Clinical Oncology.

  10. Treatment and therapeutic monitoring of canine hypothyroidism.

    PubMed

    Dixon, R M; Reid, S W J; Mooney, C T

    2002-08-01

    Thirty-one dogs with spontaneous hypothyroidism were treated with thyroid hormone replacement therapy (THRT) and monitored for approximately three months. Good clinical and laboratory control was ultimately achieved in all cases with a mean L-thyroxine (T4) dose of 0.026 mg/kg administered once daily. There was a significant increase and decrease in circulating total T4 and canine thyroid stimulating hormone (cTSH) concentrations, respectively, after starting THRT. After commencing treatment, 11 cases subsequently required an increase and three cases required a decrease in dose to achieve optimal clinical control. Median (semi interquartile range [SIR]) circulating six-hour post-pill total T4 (53.6 [27.91 nmol/litre) and cTSH (0.03 [0] microg/litre) concentrations were significantly increased and decreased, respectively, in treated dogs that did not require a dose change; corresponding values in treated dogs in which an increase in dose was required were 29.3 (12.7) nmol/litre and 0.15 (0.62) microg/litre, respectively. However, circulating cTSH measurement was of limited value in assessing therapeutic control because, although increased values were associated with inadequate therapy, reference range cTSH values were common in inadequately treated dogs. Lethargy and mental demeanour were typically the first clinical signs to improve, with significant bodyweight reduction occurring within two weeks of commencing THRT. Routine clinicopathological monitoring was of value in confirming a general metabolic response to THRT, but was of limited value in accurately monitoring cases or tailoring therapy in individual cases.

  11. Skin dose differences between intensity-modulated radiation therapy and volumetric-modulated arc therapy and between boost and integrated treatment regimens for treating head and neck and other cancer sites in patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Penoncello, Gregory P.; Ding, George X., E-mail: george.ding@vanderbilt.edu

    The purpose of this study was (1) to evaluate dose to skin between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) treatment techniques for target sites in the head and neck, pelvis, and brain and (2) to determine if the treatment dose and fractionation regimen affect the skin dose between traditional sequential boost and integrated boost regimens for patients with head and neck cancer. A total of 19 patients and 48 plans were evaluated. The Eclipse (v11) treatment planning system was used to plan therapy in 9 patients with head and neck cancer, 5 patients with prostate cancer, andmore » 5 patients with brain cancer with VMAT and static-field IMRT. The mean skin dose and the maximum dose to a contiguous volume of 2 cm{sup 3} for head and neck plans and brain plans and a contiguous volume of 5 cm{sup 3} for pelvis plans were compared for each treatment technique. Of the 9 patients with head and neck cancer, 3 underwent an integrated boost regimen. One integrated boost plan was replanned with IMRT and VMAT using a traditional boost regimen. For target sites located in the head and neck, VMAT reduced the mean dose and contiguous hot spot most noticeably in the shoulder region by 5.6% and 5.4%, respectively. When using an integrated boost regimen, the contiguous hot spot skin dose in the shoulder was larger on average than a traditional boost pattern by 26.5% and the mean skin dose was larger by 1.7%. VMAT techniques largely decrease the contiguous hot spot in the skin in the pelvis by an average of 36% compared with IMRT. For the same target coverage, VMAT can reduce the skin dose in all the regions of the body, but more noticeably in the shoulders in patients with head and neck and pelvis cancer. We also found that using integrated boost regimens in patients with head and neck cancer leads to higher shoulder skin doses compared with traditional boost regimens.« less

  12. Predictors of self-reported adherence to direct oral anticoagulation in a population of elderly men and women with non-valvular atrial fibrillation.

    PubMed

    Rossi, Andrea P; Facchinetti, Roberto; Ferrari, Elena; Nori, Nicole; Sant, Selena; Masciocchi, Elena; Zoico, Elena; Fantin, Francesco; Mazzali, Gloria; Zamboni, Mauro

    2018-05-14

    There is a general lack of studies evaluating medication adherence with self-report scales for elderly patients in treatment with direct oral anticoagulants (DOACs). The aim of the study was to assess the degree of adherence to DOAC therapy in a population of elderly outpatients aged 65 years or older affected by non-valvular atrial fibrillation (NVAF), using the 4-item Morisky Medication Adherence Scale, and to identify potential factors, including the geriatric multidimensional evaluation, which can affect adherence in the study population. A total of 103 subjects, anticoagulated with DOACs for NVAF in primary or secondary prevention, were eligible; 76 showed adequate adhesion to anticoagulant therapy, while 27 showed inadequate adherence. Participants underwent biochemical assessment and Morisky Scale, Instrumental Activities of Daily Living, CHA2DS2-VASc, HAS-BLED, mental status and nutritional evaluations were performed. 2% of subjects assumed Dabigatran at low dose, while 7.8% at standard dose, 9.7% assumed low-dose of Rivaroxaban and 30.1% at standard dose, 6.8% assumed Apixaban at low dose and 39.7% at standard dose, and finally 1% assumed Edoxaban at low dose and 2.9% at standard dose. Most subjects took the DOACs without help (80.6%), while 16 subjects were helped by a family member (15.5%) and 4 were assisted by a caregiver (3.9%). Binary logistic regression considered inappropriate adherence as a dependent variable, while age, male sex, polypharmacotherapy, cognitive decay, caregiver help for therapy assumption, duration of DOAC therapy and double daily administration were considered as independent variables. The double daily administration was an independent factor, determining inappropriate adherence with an OR of 2.88 (p = 0.048, CI 1.003-8.286).

  13. Comparative dosimetry of volumetric modulated arc therapy and limited-angle static intensity-modulated radiation therapy for early-stage larynx cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riegel, Adam C.; Antone, Jeffrey; Schwartz, David L., E-mail: dschwartz3@nshs.edu

    2013-04-01

    To compare relative carotid and normal tissue sparing using volumetric-modulated arc therapy (VMAT) or intensity-modulated radiation therapy (IMRT) for early-stage larynx cancer. Seven treatment plans were retrospectively created on 2 commercial treatment planning systems for 11 consecutive patients with T1-2N0 larynx cancer. Conventional plans consisted of opposed-wedged fields. IMRT planning used an anterior 3-field beam arrangement. Two VMAT plans were created, a full 360° arc and an anterior 180° arc. Given planning target volume (PTV) coverage of 95% total volume at 95% of 6300 cGy and maximum spinal cord dose below 2500 cGy, mean carotid artery dose was pushed asmore » low as possible for each plan. Deliverability was assessed by comparing measured and planned planar dose with the gamma (γ) index. Full-arc planning provided the most effective carotid sparing but yielded the highest mean normal tissue dose (where normal tissue was defined as all soft tissue minus PTV). Static IMRT produced next-best carotid sparing with lower normal tissue dose. The anterior half-arc produced the highest carotid artery dose, in some cases comparable with conventional opposed fields. On the whole, carotid sparing was inversely related to normal tissue dose sparing. Mean γ indexes were much less than 1, consistent with accurate delivery of planned treatment. Full-arc VMAT yields greater carotid sparing than half-arc VMAT. Limited-angle IMRT remains a reasonable alternative to full-arc VMAT, given its ability to mediate the competing demands of carotid and normal tissue dose constraints. The respective clinical significance of carotid and normal tissue sparing will require prospective evaluation.« less

  14. Comparison of Monte Carlo and analytical dose computations for intensity modulated proton therapy

    NASA Astrophysics Data System (ADS)

    Yepes, Pablo; Adair, Antony; Grosshans, David; Mirkovic, Dragan; Poenisch, Falk; Titt, Uwe; Wang, Qianxia; Mohan, Radhe

    2018-02-01

    To evaluate the effect of approximations in clinical analytical calculations performed by a treatment planning system (TPS) on dosimetric indices in intensity modulated proton therapy. TPS calculated dose distributions were compared with dose distributions as estimated by Monte Carlo (MC) simulations, calculated with the fast dose calculator (FDC) a system previously benchmarked to full MC. This study analyzed a total of 525 patients for four treatment sites (brain, head-and-neck, thorax and prostate). Dosimetric indices (D02, D05, D20, D50, D95, D98, EUD and Mean Dose) and a gamma-index analysis were utilized to evaluate the differences. The gamma-index passing rates for a 3%/3 mm criterion for voxels with a dose larger than 10% of the maximum dose had a median larger than 98% for all sites. The median difference for all dosimetric indices for target volumes was less than 2% for all cases. However, differences for target volumes as large as 10% were found for 2% of the thoracic patients. For organs at risk (OARs), the median absolute dose difference was smaller than 2 Gy for all indices and cohorts. However, absolute dose differences as large as 10 Gy were found for some small volume organs in brain and head-and-neck patients. This analysis concludes that for a fraction of the patients studied, TPS may overestimate the dose in the target by as much as 10%, while for some OARs the dose could be underestimated by as much as 10 Gy. Monte Carlo dose calculations may be needed to ensure more accurate dose computations to improve target coverage and sparing of OARs in proton therapy.

  15. Effect of Vaginal or Systemic Estrogen on Dynamics of Collagen Assembly in the Rat Vaginal Wall1

    PubMed Central

    Montoya, T. Ignacio; Maldonado, P. Antonio; Acevedo, Jesus F.; Word, R. Ann

    2014-01-01

    ABSTRACT The objective of this study was to compare the effects of systemic and local estrogen treatment on collagen assembly and biomechanical properties of the vaginal wall. Ovariectomized nulliparous rats were treated with estradiol or conjugated equine estrogens (CEEs) either systemically, vaginal CEE, or vaginal placebo cream for 4 wk. Low-dose local CEE treatment resulted in increased vaginal epithelial thickness and significant vaginal growth without uterine hyperplasia. Furthermore, vaginal wall distensibility increased without compromise of maximal force at failure. Systemic estradiol resulted in modest increases in collagen type I with no change in collagen type III mRNA. Low-dose vaginal treatment, however, resulted in dramatic increases in both collagen subtypes whereas moderate and high dose local therapies were less effective. Consistent with the mRNA results, low-dose vaginal estrogen resulted in increased total and cross-linked collagen content. The inverse relationship between vaginal dose and collagen expression may be explained in part by progressive downregulation of estrogen receptor-alpha mRNA with increasing estrogen dose. We conclude that, in this menopausal rat model, local estrogen treatment increased total and cross-linked collagen content and markedly stimulated collagen mRNA expression in an inverse dose-effect relationship. High-dose vaginal estrogen resulted in downregulation of estrogen receptor-alpha and loss of estrogen-induced increases in vaginal collagen. These results may have important clinical implications regarding the use of local vaginal estrogen therapy and its role as an adjunctive treatment in women with loss of vaginal support. PMID:25537371

  16. Effect of vaginal or systemic estrogen on dynamics of collagen assembly in the rat vaginal wall.

    PubMed

    Montoya, T Ignacio; Maldonado, P Antonio; Acevedo, Jesus F; Word, R Ann

    2015-02-01

    The objective of this study was to compare the effects of systemic and local estrogen treatment on collagen assembly and biomechanical properties of the vaginal wall. Ovariectomized nulliparous rats were treated with estradiol or conjugated equine estrogens (CEEs) either systemically, vaginal CEE, or vaginal placebo cream for 4 wk. Low-dose local CEE treatment resulted in increased vaginal epithelial thickness and significant vaginal growth without uterine hyperplasia. Furthermore, vaginal wall distensibility increased without compromise of maximal force at failure. Systemic estradiol resulted in modest increases in collagen type I with no change in collagen type III mRNA. Low-dose vaginal treatment, however, resulted in dramatic increases in both collagen subtypes whereas moderate and high dose local therapies were less effective. Consistent with the mRNA results, low-dose vaginal estrogen resulted in increased total and cross-linked collagen content. The inverse relationship between vaginal dose and collagen expression may be explained in part by progressive downregulation of estrogen receptor-alpha mRNA with increasing estrogen dose. We conclude that, in this menopausal rat model, local estrogen treatment increased total and cross-linked collagen content and markedly stimulated collagen mRNA expression in an inverse dose-effect relationship. High-dose vaginal estrogen resulted in downregulation of estrogen receptor-alpha and loss of estrogen-induced increases in vaginal collagen. These results may have important clinical implications regarding the use of local vaginal estrogen therapy and its role as an adjunctive treatment in women with loss of vaginal support. © 2015 by the Society for the Study of Reproduction, Inc.

  17. The threshold of hypothyroidism after radiation therapy for head and neck cancer: a retrospective analysis of 116 cases.

    PubMed

    Fujiwara, Masayuki; Kamikonya, Norihiko; Odawara, Soichi; Suzuki, Hitomi; Niwa, Yasue; Takada, Yasuhiro; Doi, Hiroshi; Terada, Tomonori; Uwa, Nobuhiro; Sagawa, Kosuke; Hirota, Shozo

    2015-05-01

    The purpose of the present study was to determine the risk factors for developing thyroid disorders based on a dose-volume histograms (DVHs) analysis. Data from a total of 116 consecutive patients undergoing 3D conformal radiation therapy for head and neck cancers was retrospectively evaluated. Radiation therapy was performed between April 2007 and December 2010. There were 108 males and 8 females included in the study. The median follow-up term was 24 months (range, 1-62 months). The thyroid function was evaluated by measuring thyroid-stimulating hormone (TSH) and free thyroxine (FT4) levels. The mean thyroid dose, and the volume of thyroid gland spared from doses ≥10, 20, 30 and 40 Gy (VS10, VS20, VS30 and VS40) were calculated for all patients. The thyroid dose and volume were calculated by the radiotherapy planning system (RTPS). The cumulative incidences of hypothyroidism were 21.1% and 36.4% at one year and two years, respectively, after the end of radiation therapy. In the DVH analyses, the patients who received a mean thyroid dose <30 Gy had a significantly lower incidence of hypothyroidism. The univariate analyses showed that the VS10, VS20, VS30 and VS40 were associated with the risk of hypothyroidism. Hypothyroidism was a relatively common type of late radiation-induced toxicity. A mean thyroid dose of 30 Gy may be a useful threshold for predicting the development of hypothyroidism after radiation therapy for head and neck cancers. © The Author 2015. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  18. Prospective, open, multicentre Phase I/II trial to assess safety and efficacy of neoadjuvant radiochemotherapy with docetaxel and cisplatin for esophageal carcinoma.

    PubMed

    Ma, Hong-Bing; Di, Zheng-Li; Wen, Jiao; Ke, Yue; Sun, Xiaodong; Ren, Juan

    2015-02-01

    Esophageal squamous cell carcinoma is increasingly treated with trimodality therapy. The objective of this Phase I/II clinical study is to assess the efficacy and safety of neoadjuvant radiochemotherapy with docetaxel and cisplatin and radiotherapy in patients with esophagectomy for locally advanced squamous cell carcinoma of the esophagus with neoadjuvant chemoradiotherapy. Patients with esophageal squamous cell carcinoma received radiochemotherapy (50 Gy/25 fractions during Weeks 1-5) using a three-dimensional conformal radiation therapy or intensity-modulated radiation therapy technique together with weekly docetaxel (20 mg/m(2) at dose levels 1 and 2, 25 mg/m(2) at dose level 3 on Weeks 1-5) and cisplatin (30 mg/m(2) at dose level 1, 40 mg/m(2) at dose levels 2 and 3 on Weeks 1-5) from January 2009 to December 2011. The dose-limiting toxicities and maximum tolerated dose were the primary endpoints and overall response rate and progression-free survival were the secondary endpoints. Over this timeframe, a total of 49 patients completed trimodality therapy. Thirteen patients were treated at dose level 1, 21 patients at dose level 2 and 15 patients at dose level 3.The maximum tolerated dose for docetaxel was 20 mg/m(2) and cisplatin 40 mg/m(2). The complete response or partial response was observed in 26.5% (13/49) of patients. Thirty-four patients (69.4%) were treated with neoadjuvant radiochemotherapy followed by surgical resection. The median progression-free survival and median overall survival for all patients (n = 49) were 8 and 17.2 months, respectively. The median overall survival was 27.5 months for patients treated at dose level 2. Neoadjuvant radiochemotherapy with docetaxel 20 mg/m(2) and cisplatin 40 mg/m(2) was effective and tolerable induction regimen in patients with esophageal tumors. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. 4D cone-beam CT imaging for guidance in radiation therapy: setup verification by use of implanted fiducial markers

    NASA Astrophysics Data System (ADS)

    Jin, Peng; van Wieringen, Niek; Hulshof, Maarten C. C. M.; Bel, Arjan; Alderliesten, Tanja

    2016-03-01

    The use of 4D cone-beam computed tomography (CBCT) and fiducial markers for guidance during radiation therapy of mobile tumors is challenging due to the trade-off between image quality, imaging dose, and scanning time. We aimed to investigate the visibility of markers and the feasibility of marker-based 4D registration and manual respiration-induced marker motion quantification for different CBCT acquisition settings. A dynamic thorax phantom and a patient with implanted gold markers were included. For both the phantom and patient, the peak-to-peak amplitude of marker motion in the cranial-caudal direction ranged from 5.3 to 14.0 mm, which did not affect the marker visibility and the associated marker-based registration feasibility. While using a medium field of view (FOV) and the same total imaging dose as is applied for 3D CBCT scanning in our clinic, it was feasible to attain an improved marker visibility by reducing the imaging dose per projection and increasing the number of projection images. For a small FOV with a shorter rotation arc but similar total imaging dose, streak artifacts were reduced due to using a smaller sampling angle. Additionally, the use of a small FOV allowed reducing total imaging dose and scanning time (~2.5 min) without losing the marker visibility. In conclusion, by using 4D CBCT with identical or lower imaging dose and a reduced gantry speed, it is feasible to attain sufficient marker visibility for marker-based 4D setup verification. Moreover, regardless of the settings, manual marker motion quantification can achieve a high accuracy with the error <1.2 mm.

  20. Study for reducing lung dose of upper thoracic esophageal cancer radiotherapy by auto-planning: volumetric-modulated arc therapy vs intensity-modulated radiation therapy.

    PubMed

    Chen, Hua; Wang, Hao; Gu, Hengle; Shao, Yan; Cai, Xuwei; Fu, Xiaolong; Xu, Zhiyong

    2017-10-27

    This study aimed to investigate the dosimetric differences and lung sparing between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) in the treatment of upper thoracic esophageal cancer with T3N0M0 for preoperative radiotherapy by auto-planning (AP). Sixteen patient cases diagnosed with upper thoracic esophageal cancer T3N0M0 for preoperative radiotherapy were retrospectively studied, and 3 plans were generated for each patient: full arc VMAT AP plan with double arcs, partial arc VMAT AP plan with 6 partial arcs, and conventional IMRT AP plan. A simultaneous integrated boost with 2 levels was planned in all patients. Target coverage, organ at risk sparing, treatment parameters including monitor units and treatment time (TT) were evaluated. Wilcoxon signed-rank test was used to check for significant differences (p < 0.05) between datasets. VMAT plans (pVMAT and fVMAT) significantly reduced total lung volume treated above 20 Gy (V 20 ), 25 Gy (V 25 ), 30 Gy (V 30 ), 35 Gy (V 35 ), 40 Gy (V 40 ), and without increasing the value of V 10 , V 13 , and V 15 . For V 5 of total lung value, pVMAT was similar to aIMRT, and it was better than fVMAT. Both pVMAT and fVMAT improved the target dose coverage and significantly decreased maximum dose for the spinal cord, monitor unit, and TT. No significant difference was observed with respect to V 10 and V 15 of body. VMAT AP plan was a good option for treating upper thoracic esophageal cancer with T3N0M0, especially partial arc VMAT AP plan. It had the potential to effectively reduce lung dose in a shorter TT and with superior target coverage and dose homogeneity. Copyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  1. Three-Dimensional Dose Calculation for Total Body Irradiation

    NASA Astrophysics Data System (ADS)

    Ito, Akira

    Bone Marrow Transplant (BMT) therapy has been a big success in the treatment of leukemia and other haematopoietic diseases 1 . Prior to BMT, total body irradiation (TBI) is given to the patient for the purpose of (1) killing leukemia cells in bone marrow, as well as in the whole body, and (2) producing immuno-suppressive status in the patient so that the donor's marrow cells will be transplanted without rejection. TBI employs a very large field photon beam to irradiate the whole body of the patient. A uniform dose distribution over the entire body is the treatment goal. To prevent the occurrence of a serious side effect (interstitial pneumonia), the lung dose should not exceed a certain level. This novel technique poses various new radiological physics problems. The accurate assessment of dose and dose distribution in the patient is essential. Physical and dosimetric problems associated with TBI are reviewed elsewhere 2,3 .

  2. ¹⁸F-choline positron emission tomography/computed tomography-driven high-dose salvage radiation therapy in patients with biochemical progression after radical prostatectomy: feasibility study in 60 patients.

    PubMed

    D'Angelillo, Rolando M; Sciuto, Rosa; Ramella, Sara; Papalia, Rocco; Jereczek-Fossa, Barbara A; Trodella, Luca E; Fiore, Michele; Gallucci, Michele; Maini, Carlo L; Trodella, Lucio

    2014-10-01

    To retrospectively review data of a cohort of patients with biochemical progression after radical prostatectomy, treated according to a uniform institutional treatment policy, to evaluate toxicity and feasibility of high-dose salvage radiation therapy (80 Gy). Data on 60 patients with biochemical progression after radical prostatectomy between January 2009 and September 2011 were reviewed. The median value of prostate-specific antigen before radiation therapy was 0.9 ng/mL. All patients at time of diagnosis of biochemical recurrence underwent dynamic (18)F-choline positron emission tomography/computed tomography (PET/CT), which revealed in all cases a local recurrence. High-dose salvage radiation therapy was delivered up to total dose of 80 Gy to 18F-choline PET/CT-positive area. Toxicity was recorded according to the Common Terminology Criteria for Adverse Events, version 3.0, scale. Treatment was generally well tolerated: 54 patients (90%) completed salvage radiation therapy without any interruption. Gastrointestinal grade ≥2 acute toxicity was recorded in 6 patients (10%), whereas no patient experienced a grade ≥2 genitourinary toxicity. No grade 4 acute toxicity events were recorded. Only 1 patient (1.7%) experienced a grade 2 gastrointestinal late toxicity. With a mean follow-up of 31.2 months, 46 of 60 patients (76.6%) were free of recurrence. The 3-year biochemical progression-free survival rate was 72.5%. At early follow-up, (18)F-choline PET/CT-driven high-dose salvage radiation therapy seems to be feasible and well tolerated, with a low rate of toxicity. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. {sup 18}F-Choline Positron Emission Tomography/Computed Tomography–Driven High-Dose Salvage Radiation Therapy in Patients With Biochemical Progression After Radical Prostatectomy: Feasibility Study in 60 Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D'Angelillo, Rolando M., E-mail: r.dangelillo@unicampus.it; Sciuto, Rosa; Ramella, Sara

    Purpose: To retrospectively review data of a cohort of patients with biochemical progression after radical prostatectomy, treated according to a uniform institutional treatment policy, to evaluate toxicity and feasibility of high-dose salvage radiation therapy (80 Gy). Methods and Materials: Data on 60 patients with biochemical progression after radical prostatectomy between January 2009 and September 2011 were reviewed. The median value of prostate-specific antigen before radiation therapy was 0.9 ng/mL. All patients at time of diagnosis of biochemical recurrence underwent dynamic {sup 18}F-choline positron emission tomography/computed tomography (PET/CT), which revealed in all cases a local recurrence. High-dose salvage radiation therapy was delivered up tomore » total dose of 80 Gy to 18F-choline PET/CT-positive area. Toxicity was recorded according to the Common Terminology Criteria for Adverse Events, version 3.0, scale. Results: Treatment was generally well tolerated: 54 patients (90%) completed salvage radiation therapy without any interruption. Gastrointestinal grade ≥2 acute toxicity was recorded in 6 patients (10%), whereas no patient experienced a grade ≥2 genitourinary toxicity. No grade 4 acute toxicity events were recorded. Only 1 patient (1.7%) experienced a grade 2 gastrointestinal late toxicity. With a mean follow-up of 31.2 months, 46 of 60 patients (76.6%) were free of recurrence. The 3-year biochemical progression-free survival rate was 72.5%. Conclusions: At early follow-up, {sup 18}F-choline PET/CT-driven high-dose salvage radiation therapy seems to be feasible and well tolerated, with a low rate of toxicity.« less

  4. Dose-Effect Relationships for Adverse Events After Cranial Radiation Therapy in Long-term Childhood Cancer Survivors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dijk, Irma W.E.M. van, E-mail: i.w.vandijk@amc.uva.nl; Cardous-Ubbink, Mathilde C.; Pal, Helena J.H. van der

    Purpose: To evaluate the prevalence and severity of clinical adverse events (AEs) and treatment-related risk factors in childhood cancer survivors treated with cranial radiation therapy (CRT), with the aim of assessing dose-effect relationships. Methods and Materials: The retrospective study cohort consisted of 1362 Dutch childhood cancer survivors, of whom 285 were treated with CRT delivered as brain irradiation (BI), as part of craniospinal irradiation (CSI), and as total body irradiation (TBI). Individual CRT doses were converted into the equivalent dose in 2-Gy fractions (EQD{sub 2}). Survivors had received their diagnoses between 1966 and 1996 and survived at least 5 yearsmore » after diagnosis. A complete inventory of Common Terminology Criteria for Adverse Events grade 3.0 AEs was available from our hospital-based late-effect follow-up program. We used multivariable logistic and Cox regression analyses to examine the EQD{sub 2} in relation to the prevalence and severity of AEs, correcting for sex, age at diagnosis, follow-up time, and the treatment-related risk factors surgery and chemotherapy. Results: There was a high prevalence of AEs in the CRT group; over 80% of survivors had more than 1 AE, and almost half had at least 5 AEs, both representing significant increases in number of AEs compared with survivors not treated with CRT. Additionally, the proportion of severe, life-threatening, or disabling AEs was significantly higher in the CRT group. The most frequent AEs were alopecia and cognitive, endocrine, metabolic, and neurologic events. Using the EQD{sub 2}, we found significant dose-effect relationships for these and other AEs. Conclusion: Our results confirm that CRT increases the prevalence and severity of AEs in childhood cancer survivors. Furthermore, analyzing dose-effect relationships with the cumulative EQD{sub 2} instead of total physical dose connects the knowledge from radiation therapy and radiobiology with the clinical experience.« less

  5. Upper bound dose values for meson radiation in heavy-ion therapy.

    PubMed

    Rabin, C; Gonçalves, M; Duarte, S B; González-Sprinberg, G A

    2018-06-01

    Radiation treatment of cancer has evolved to include massive particle beams, instead of traditional irradiation procedures. Thus, patient doses and worker radiological protection have become issues of constant concern in the use of these new technologies, especially for proton- and heavy-ion-therapy. In the beam energies of interest of heavy-ion-therapy, secondary particle radiation comes from proton, neutron, and neutral and charged pions produced in the nuclear collisions of the beam with human tissue atoms. This work, for the first time, offers the upper bound of meson radiation dose in organic tissues due to secondary meson radiation in heavy-ion therapy. A model based on intranuclear collision has been used to follow in time the nuclear reaction and to determine the secondary radiation due to the meson yield produced in the beam interaction with nuclei in the tissue-equivalent media and water. The multiplicity, energy spectrum, and angular distribution of these pions, as well as their decay products, have been calculated in different scenarios for the nuclear reaction mechanism. The results of the produced secondary meson particles has been used to estimate the energy deposited in tissue using a cylindrical phantom by a transport Monte Carlo simulation and we have concluded that these mesons contribute at most 0.1% of the total prescribed dose.

  6. Clinical results of proton beam therapy for twenty older patients with esophageal cancer

    PubMed Central

    Ono, Takashi; Nakamura, Tatsuya; Azami, Yusuke; Yamaguchi, Hisashi; Hayashi, Yuichiro; Suzuki, Motohisa; Hatayama, Yoshiomi; Tsukiyama, Iwao; Hareyama, Masato; Kikuchi, Yasuhiro; Nemoto, Kenji

    2015-01-01

    Background In an aging society, increasing number of older patients are diagnosed with esophageal cancer. The purpose of this study was to assess the clinical efficacy and safety of proton beam therapy for older patients with esophageal cancer. Patients and methods. Older patients (age: ≥ 65 years) newly diagnosed with esophageal cancer between January 2009 and June 2013 were enrolled in this study. All patients underwent either proton beam therapy alone or proton beam therapy with initial X-ray irradiation. Toxicities were evaluated using the Common Terminology Criteria for Adverse Events version 4.0. Results Twenty patients were eligible for this study and all completed the treatment. The median age was 78 years (range: 65–89 years) and the median follow-up time was 26.5 months (range: 6–62 months). Seven patients had lymph node metastases and 10 had stage II/III cancer. The median dose of proton beam therapy was 72.6 Gy relative biological dose effectiveness (RBE) (range: 66–74.8 Gy [RBE]) for proton beam therapy alone and 33 Gy (RBE) (range: 30.8–39.6 Gy [RBE]; total dose range: 66.8–75.6 Gy [RBE]) for proton beam therapy with initial X-ray irradiation. The 2-year overall survival rate was 81.8% (95% confidence interval [CI]: 62.4%–100%), and the 2-year local control rate was 89.4% (95% CI: 75.5%–100%). Grade 2 or 3 toxicities occurred in some cases; however, no grade 4 or 5 toxicity was observed. Conclusions High-dose (66–75.6 Gy [RBE]) proton beam therapy without chemotherapy was an efficacious and safe treatment for older patients with esophageal cancer. PMID:26834524

  7. Dosimetric comparison of hybrid volumetric-modulated arc therapy, volumetric-modulated arc therapy, and intensity-modulated radiation therapy for left-sided early breast cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Jia-Fu; Yeh, Dah-Cherng; Yeh, Hui-Ling, E-mail: hlyeh@vghtc.gov.tw

    2015-10-01

    To compare the dosimetric performance of 3 different treatment techniques: hybrid volumetric-modulated arc therapy (hybrid-VMAT), pure-VMAT, and fixed-field intensity-modulated radiation therapy (F-IMRT) for whole-breast irradiation of left-sided early breast cancer. The hybrid-VMAT treatment technique and 2 other treatment techniques—pure-VMAT and F-IMRT—were compared retrospectively in 10 patients with left-sided early breast cancer. The treatment plans of these patients were replanned using the same contours based on the original computed tomography (CT) data sets. Dosimetric parameters were calculated to evaluate plan quality. Total monitor units (MUs) and delivery time were also recorded and evaluated. The hybrid-VMAT plan generated the best results inmore » dose coverage of the target and the dose uniformity inside the target (p < 0.0001 for conformal index [CI]; p = 0.0002 for homogeneity index [HI] of planning target volume [PTV]{sub 50.4} {sub Gy} and p < 0.0001 for HI of PTV{sub 62} {sub Gy}). Volumes of ipsilateral lung irradiated to doses of 20 Gy (V{sub 20} {sub Gy}) and 5 Gy (V{sub 5} {sub Gy}) by the hybrid-VMAT plan were significantly less than those of the F-IMRT and the pure-VMAT plans. The volume of ipsilateral lung irradiated to a dose of 5 Gy was significantly less using the hybrid-VMAT plan than that using the F-IMRT or the pure-VMAT plan. The total mean MUs for the hybrid-VMAT plan were significantly less than those for the F-IMRT or the pure-VMAT plan. The mean machine delivery time was 3.23 ± 0.29 minutes for the hybrid-VMAT plans, which is longer than that for the pure-VMAT plans but shorter than that for the F-IMRT plans. The hybrid-VMAT plan is feasible for whole-breast irradiation of left-sided early breast cancer.« less

  8. Stereology techniques in radiation biology

    NASA Technical Reports Server (NTRS)

    Kubinova, Lucie; Mao, XiaoWen; Janacek, Jiri; Archambeau, John O.; Nelson, G. A. (Principal Investigator)

    2003-01-01

    Clinicians involved in conventional radiation therapy are very concerned about the dose-response relationships of normal tissues. Before proceeding to new clinical protocols, radiation biologists involved with conformal proton therapy believe it is necessary to quantify the dose response and tolerance of the organs and tissues that will be irradiated. An important focus is on the vasculature. This presentation reviews the methodology and format of using confocal microscopy and stereological methods to quantify tissue parameters, cell number, tissue volume and surface area, and vessel length using the microvasculature as a model tissue. Stereological methods and their concepts are illustrated using an ongoing study of the dose response of the microvessels in proton-irradiated hemibrain. Methods for estimating the volume of the brain and the brain cortex, the total number of endothelial cells in cortical microvessels, the length of cortical microvessels, and the total surface area of cortical microvessel walls are presented step by step in a way understandable for readers with little mathematical background. It is shown that stereological techniques, based on a sound theoretical basis, are powerful and reliable and have been used successfully.

  9. Clinical application of 3D-printed-step-bolus in post-total-mastectomy electron conformal therapy.

    PubMed

    Park, Kwangwoo; Park, Sungjin; Jeon, Mi-Jin; Choi, Jinhyun; Kim, Jun Won; Cho, Yoon Jin; Jang, Won-Seok; Keum, Yo Sup; Lee, Ik Jae

    2017-04-11

    The 3D-printed boluses were used during the radiation therapy of the chest wall in six patients with breast cancer after modified radical mastectomy (MRM). We measured the in-vivo skin doses while both conventional and 3D-printed boluses were placed on the chest wall and compared the mean doses delivered to the ipsilateral lung and the heart. The homogeneity and conformity of the dose distribution in the chest wall for both types of boluses were also evaluated. The uniformity index on the chest skin was improved when the 3D-printed boluses were used, with the overall average skin dose being closer to the prescribed one in the former case (-0.47% versus -4.43%). On comparing the dose-volume histogram (DVH), it was found that the 3D-printed boluses resulted in a reduction in the mean dose to the ipsilateral lung by up to 20%. The precision of dose delivery was improved by 3% with the 3D-printed boluses; in contrast, the conventional step bolus resulted in a precision level of 5%. In conclusion, the use of the 3D-printed boluses resulted in better dose homogeneity and conformity to the chest wall as well as the sparing of the normal organs, especially the lung. This suggested that their routine use on the chest wall as a therapeutic approach during post-mastectomy radiation therapy offers numerous advantages over conventional step boluses.

  10. Clinical application of 3D-printed-step-bolus in post-total-mastectomy electron conformal therapy

    PubMed Central

    Park, Kwangwoo; Park, Sungjin; Jeon, Mi-Jin; Choi, Jinhyun; Kim, Jun Won; Cho, Yoon Jin; Jang, Won-Seok; Keum, Yo Sup; Lee, Ik Jae

    2017-01-01

    The 3D-printed boluses were used during the radiation therapy of the chest wall in six patients with breast cancer after modified radical mastectomy (MRM). We measured the in-vivo skin doses while both conventional and 3D-printed boluses were placed on the chest wall and compared the mean doses delivered to the ipsilateral lung and the heart. The homogeneity and conformity of the dose distribution in the chest wall for both types of boluses were also evaluated. The uniformity index on the chest skin was improved when the 3D-printed boluses were used, with the overall average skin dose being closer to the prescribed one in the former case (-0.47% versus -4.43%). On comparing the dose-volume histogram (DVH), it was found that the 3D-printed boluses resulted in a reduction in the mean dose to the ipsilateral lung by up to 20%. The precision of dose delivery was improved by 3% with the 3D-printed boluses; in contrast, the conventional step bolus resulted in a precision level of 5%. In conclusion, the use of the 3D-printed boluses resulted in better dose homogeneity and conformity to the chest wall as well as the sparing of the normal organs, especially the lung. This suggested that their routine use on the chest wall as a therapeutic approach during post-mastectomy radiation therapy offers numerous advantages over conventional step boluses. PMID:27784001

  11. Phase I/II clinical trial of 2-Difluoromethylornithine (DFMO) and a novel polyamine transport inhibitor (MQT 1426) for feline oral squamous cell carcinoma

    PubMed Central

    Skorupski, Katherine A.; O'Brien, Thomas G.; Guerrero, Teri; Rodriguez, Carlos O.; Burns, Mark R.

    2011-01-01

    Polyamines are essential for cell proliferation. Their production is dysregulated in many cancers and polyamine depletion leads to tumor regression in mouse models of SCC. The purpose of this study was to determine the maximally tolerated dose of the polyamine transport inhibitor, MQT 1426, when combined with the ornithine decarboxylase inhibitor, DFMO, and to determine whether this therapy results in reduction in tumor polyamine levels. Thirteen cats with oral SCC received both drugs orally and serial tumor biopsies were obtained for polyamine measurement. Cats were monitored for response to therapy and toxicity. A maximum tolerated dose of MQT 1426 when combined with DFMO was determined. Dose limiting toxicity was vestibular in nature, but was fully reversible. Spermidine and total polyamine levels decreased significantly in tissues, 2 cats experienced objective tumor regression, and 6 cats had stable disease. These results suggest that further study of polyamine depletion therapies is warranted. PMID:22077408

  12. TH-A-19A-06: Site-Specific Comparison of Analytical and Monte Carlo Based Dose Calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schuemann, J; Grassberger, C; Paganetti, H

    2014-06-15

    Purpose: To investigate the impact of complex patient geometries on the capability of analytical dose calculation algorithms to accurately predict dose distributions and to verify currently used uncertainty margins in proton therapy. Methods: Dose distributions predicted by an analytical pencilbeam algorithm were compared with Monte Carlo simulations (MCS) using TOPAS. 79 complete patient treatment plans were investigated for 7 disease sites (liver, prostate, breast, medulloblastoma spine and whole brain, lung and head and neck). A total of 508 individual passively scattered treatment fields were analyzed for field specific properties. Comparisons based on target coverage indices (EUD, D95, D90 and D50)more » were performed. Range differences were estimated for the distal position of the 90% dose level (R90) and the 50% dose level (R50). Two-dimensional distal dose surfaces were calculated and the root mean square differences (RMSD), average range difference (ARD) and average distal dose degradation (ADD), the distance between the distal position of the 80% and 20% dose levels (R80- R20), were analyzed. Results: We found target coverage indices calculated by TOPAS to generally be around 1–2% lower than predicted by the analytical algorithm. Differences in R90 predicted by TOPAS and the planning system can be larger than currently applied range margins in proton therapy for small regions distal to the target volume. We estimate new site-specific range margins (R90) for analytical dose calculations considering total range uncertainties and uncertainties from dose calculation alone based on the RMSD. Our results demonstrate that a reduction of currently used uncertainty margins is feasible for liver, prostate and whole brain fields even without introducing MC dose calculations. Conclusion: Analytical dose calculation algorithms predict dose distributions within clinical limits for more homogeneous patients sites (liver, prostate, whole brain). However, we recommend treatment plan verification using Monte Carlo simulations for patients with complex geometries.« less

  13. The threshold of hypothyroidism after radiation therapy for head and neck cancer: a retrospective analysis of 116 cases

    PubMed Central

    Fujiwara, Masayuki; Kamikonya, Norihiko; Odawara, Soichi; Suzuki, Hitomi; Niwa, Yasue; Takada, Yasuhiro; Doi, Hiroshi; Terada, Tomonori; Uwa, Nobuhiro; Sagawa, Kosuke; Hirota, Shozo

    2015-01-01

    The purpose of the present study was to determine the risk factors for developing thyroid disorders based on a dose–volume histograms (DVHs) analysis. Data from a total of 116 consecutive patients undergoing 3D conformal radiation therapy for head and neck cancers was retrospectively evaluated. Radiation therapy was performed between April 2007 and December 2010. There were 108 males and 8 females included in the study. The median follow-up term was 24 months (range, 1–62 months). The thyroid function was evaluated by measuring thyroid-stimulating hormone (TSH) and free thyroxine (FT4) levels. The mean thyroid dose, and the volume of thyroid gland spared from doses ≥10, 20, 30 and 40 Gy (VS10, VS20, VS30 and VS40) were calculated for all patients. The thyroid dose and volume were calculated by the radiotherapy planning system (RTPS). The cumulative incidences of hypothyroidism were 21.1% and 36.4% at one year and two years, respectively, after the end of radiation therapy. In the DVH analyses, the patients who received a mean thyroid dose <30 Gy had a significantly lower incidence of hypothyroidism. The univariate analyses showed that the VS10, VS20, VS30 and VS40 were associated with the risk of hypothyroidism. Hypothyroidism was a relatively common type of late radiation-induced toxicity. A mean thyroid dose of 30 Gy may be a useful threshold for predicting the development of hypothyroidism after radiation therapy for head and neck cancers. PMID:25818629

  14. Ultrasound-guided corticosteroid injection therapy for juvenile idiopathic arthritis: 12-year care experience.

    PubMed

    Young, Cody M; Shiels, William E; Coley, Brian D; Hogan, Mark J; Murakami, James W; Jones, Karla; Higgins, Gloria C; Rennebohm, Robert M

    2012-12-01

    Intra-articular corticosteroid injections are a safe and effective treatment for patients with juvenile idiopathic arthritis. The potential scope of care in ultrasound-guided corticosteroid therapy in children and a joint-based corticosteroid dose protocol designed to optimize interdisciplinary care are not found in the current literature. The purpose of this study was to report the spectrum of care, technique and safety of ultrasound-guided corticosteroid injection therapy in patients with juvenile idiopathic arthritis and to propose an age-weight-joint-based corticosteroid dose protocol. A retrospective analysis was performed of 198 patients (ages 21 months to 28 years) referred for treatment of juvenile idiopathic arthritis with corticosteroid therapy. Symptomatic joints and tendon sheaths were treated as prescribed by the referring rheumatologist. An age-weight-joint-based dose protocol was developed and utilized for corticosteroid dose prescription. A total of 1,444 corticosteroid injections (1,340 joints, 104 tendon sheaths) were performed under US guidance. Injection sites included small, medium and large appendicular skeletal joints (upper extremity 497, lower extremity 837) and six temporomandibular joints. For patients with recurrent symptoms, 414 repeat injections were performed, with an average time interval of 17.7 months (range, 0.5-101.5 months) between injections. Complications occurred in 2.6% of injections and included subcutaneous tissue atrophy, skin hypopigmentation, erythema and pruritis. US-guided corticosteroid injection therapy provides dynamic, precise and safe treatment of a broad spectrum of joints and tendon sheaths throughout the entire pediatric musculoskeletal system. An age-weight-joint-based corticosteroid dose protocol is effective and integral to interdisciplinary care of patients with juvenile idiopathic arthritis.

  15. Retrospective investigation of testosterone undecanoate depot for the long-term treatment of male hypogonadism in clinical practice.

    PubMed

    Conaglen, Helen M; Paul, Ryan G; Yarndley, Tania; Kamp, Jozef; Elston, Marianne S; Conaglen, John V

    2014-02-01

    Testosterone undecanoate depot (TUD) administered intramuscularly is an effective form of testosterone replacement therapy (TRT) for male hypogonadism. Because of the ease of administration, TUD therapy may be preferable to subcutaneously implanted extended release T pellet implants (TI). The primary objective was to retrospectively assess the efficacy and safety of long-term (≥ 2 years therapy) TUD therapy in the clinical setting. The secondary objective was to retrospectively compare TUD with TI therapy. Retrospective data were collected from the Waikato Hospital Endocrine Database for 179 hypogonadal men treated with TUD for ≥ 2 years from 1998-2011, with 124 of these men receiving previous TI therapy. The main outcome measure for efficacy was serum trough total testosterone (TT), and for safety an increase in hemoglobin (Hb) and/or hematocrit (Hct), rise in prostate-specific antigen (PSA) and/or prostatic biopsy and alteration in body mass index and lipid profile. Additional outcome measures were changes in the dosing and/or interval regimens for TUD therapy. Overall, 72% of trough TT levels were in the normal range for TUD therapy compared with 53% of trough TT levels during TI therapy. TUD therapy was well tolerated with 162 men (90.5%) completing 2 years of treatment, and only seven men (3.9%) stopping TUD because of adverse effects. A rise in Hb and/or Hct occurred in 25 men (14%), and a significant rise in PSA in 20 men (13%) at some stage during TUD therapy. At 2 years, 91% of men received the standard 1,000 mg TUD dose with 66% at the standard dosing interval of 10-14 weekly. TUD is an efficacious, safe, and well tolerated form of TRT, and individual optimisation of the dose and/or interval is only required in the minority of men. Particularly given the ease of administration, TUD was the preferred TRT for both patients and clinicians. © 2013 International Society for Sexual Medicine.

  16. PUVA therapy for palmoplantar pustulosis.

    PubMed

    Agren-Jonsson, S; Tegner, E

    1985-01-01

    Forty patients suffering from pustulosis palmoplantaris were treated with PUVA therapy. Thirty-six patients had palmar lesions which cleared in 31 cases; in 18 cases after an initial course of 3 sessions of treatment per week during an average period of 10 weeks, and in another 13 only after additional, less frequent continuation of the PUVA therapy. The average total UVA dose at clearing of the palmar lesions was 191 and the final UVA dose 7.3 J/cm2. After 2 years, 9 out of the 31 cases of palmar lesions were still completely healed, and the average duration of remission was greater than or equal to 15 months. For plantar lesions the results of PUVA therapy, using essentially the same procedure, were less satisfactory: healing being obtained in only 5 out of 34 cases. However, for palmar and plantar lesions alike, most patients have reported long-standing improvement from PUVA therapy. A surprisingly high frequency of nausea was noted as a side-effect.

  17. Evaluation of dose variation during total skin electron irradiation using thermoluminescent dosimeters.

    PubMed

    Weaver, R D; Gerbi, B J; Dusenbery, K E

    1995-09-30

    To determine acceptable dose variation using thermoluminescent dosimeters (TLD) in the treatment of Mycosis Fungoides with total skin electron beam (TSEB) irradiation. From 1983 to 1993, 22 patients were treated with total skin electron beam therapy in the standing position. A six-field technique was used to deliver 2 Gy in two days, treating 4 days per week, to a total dose of 35 to 40 Gy using a degraded 9 MeV electron beam. Thermoluminescent dosimeters were placed on several locations of the body and the results recorded. The variations in these readings were analyzed to determine normal dose variation for various body locations during TSEB. The dose to flat surfaces of the body was essentially the same as the dose to the prescription point. The dose to tangential surfaces was within +/- 10% of the prescription dose, but the readings showed much more variation (up to 24%). Thin areas of the body showed large deviations from the prescription dose along with a large amount of variation in the readings (up to 22%). Special areas of the body, such as the perineum and eyelid, showed large deviations from the prescription dose with very large (up to 40%) variations in the readings. The TLD results of this study will be used as a quality assurance check for all new patients treated with TSEB. The results of the TLDs will be compared with this baseline study to determine if the delivered dose is within acceptable ranges. If the TLD results fall outside the acceptable limits established above, then the patient position can be modified or the technique itself evaluated.

  18. SU-F-P-50: Performance Evaluation of Optically Stimulated Luminescence (OSL) NanoDots in Therapy and Imaging In-Vivo Dose Measurement During Patient Treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, S; Sarkar, B; Kaur, H

    Purpose: This study was designed to evaluate the performance of optically stimulated Luminescence (OSL) nanoDots as in-vivo dosimeter. For the measurements of surface doses as well as scattered plus leakage doses, nanoDots were used during the setup verification as well as during the treatment delivery. Methods: For a total seven patients undergoing radiotherapy by volumetric modulated arc therapy, surface doses from image guidance and scattered plus leakage doses from treatment delivery were measured. Two sets of calibration curves were generated – one for therapy and another for imaging. Two different nanoDots were used for imaging and therapy doses. Imaging nanoDotsmore » were placed at the isocenter only at the time of CBCT and therapy nanoDots were placed at 25 cm away from the isocenter (either in cranial or in caudal direction) only at the time of treatment delivery. During the entire course, nanoDots were placed at the same measurement points. NanoDots were read after 15 minutes of their exposure. For the next fraction, nanoDots were corrected for the residual doses from the previous fractions. Results: Measured surface doses during imaging were 0.14±0.32 cGy, 0.11±0.04 cGy, 0.12±0.53 cGy, 0.04±0.02 cGy, 0.13±0.23 cGy, 0.11±0.43 cGy, 0.10±0.04 cGy with overall mean dose of 0.08±0.1 cGy. Measured doses during treatment delivery, indicative of scattered and leakage dose, were 0.84±0.43 cGy, 1.3±0.4 cGy, 1.4±0.4 cGy, 0.18±0.48 cGy, 0.78±0.29 cGy, 0.27±0.08 cGy, 0.78±0.07 cGy with overall mean dose of 0.61±1.3 cGy. Conclusion: This dosimeter can be used as supplementary unit to verify the doses. No change in the prescription is recommended based on nanoDots measurement. This study is on-going therefore we are presenting only mere number of patients. A large volume data will be presented after completion of the study with proper statistical analysis.« less

  19. Assessment of radiation-induced second cancer risks in proton therapy and IMRT for organs inside the primary radiation field

    NASA Astrophysics Data System (ADS)

    Paganetti, Harald; Athar, Basit S.; Moteabbed, Maryam; Adams, Judith A.; Schneider, Uwe; Yock, Torunn I.

    2012-10-01

    There is clinical evidence that second malignancies in radiation therapy occur mainly within the beam path, i.e. in the medium or high-dose region. The purpose of this study was to assess the risk for developing a radiation-induced tumor within the treated volume and to compare this risk for proton therapy and intensity-modulated photon therapy (IMRT). Instead of using data for specific patients we have created a representative scenario. Fully contoured age- and gender-specific whole body phantoms (4 year and 14 year old) were uploaded into a treatment planning system and tumor volumes were contoured based on patients treated for optic glioma and vertebral body Ewing's sarcoma. Treatment plans for IMRT and proton therapy treatments were generated. Lifetime attributable risks (LARs) for developing a second malignancy were calculated using a risk model considering cell kill, mutation, repopulation, as well as inhomogeneous organ doses. For standard fractionation schemes, the LAR for developing a second malignancy from radiation therapy alone was found to be up to 2.7% for a 4 year old optic glioma patient treated with IMRT considering a soft-tissue carcinoma risk model only. Sarcoma risks were found to be below 1% in all cases. For a 14 year old, risks were found to be about a factor of 2 lower. For Ewing's sarcoma cases the risks based on a sarcoma model were typically higher than the carcinoma risks, i.e. LAR up to 1.3% for soft-tissue sarcoma. In all cases, the risk from proton therapy turned out to be lower by at least a factor of 2 and up to a factor of 10. This is mainly due to lower total energy deposited in the patient when using proton beams. However, the comparison of a three-field and four-field proton plan also shows that the distribution of the dose, i.e. the particular treatment plan, plays a role. When using different fractionation schemes, the estimated risks roughly scale with the total dose difference in%. In conclusion, proton therapy can significantly reduce the risk for developing an in-field second malignancy. The risk depends on treatment planning parameters, i.e. an analysis based on our formalism could be applied within treatment planning programs to guide treatment plans for pediatric patients.

  20. TH-AB-BRB-01: Trajectory Modulated Arc Therapy: Application to Partial Breast Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hristov, D.

    2016-06-15

    Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapymore » involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.« less

  1. Efficacy and safety of teneligliptin in addition to insulin therapy in type 2 diabetes mellitus patients on hemodialysis evaluated by continuous glucose monitoring.

    PubMed

    Yajima, Takahiro; Yajima, Kumiko; Hayashi, Makoto; Takahashi, Hiroshi; Yasuda, Keigo

    2016-12-01

    Appropriate glycemic control without hypoglycemia is important in patients with type 2 diabetes on hemodialysis. Teneligliptin, a novel dipeptidyl peptidase-4 inhibitor, can be used without dose adjustment for these patients. Using continuous glucose monitoring (CGM), we evaluated the efficacy and safety of adding teneligliptin to insulin therapy. Twenty-one type 2 diabetes mellitus patients on hemodialysis treated with insulin were enrolled. After the adjustment of insulin dose, their blood glucose level was monitored by CGM. Insulin dose was reduced after teneligliptin administration. The median total daily insulin dose significantly reduced from 18 (9-24)U to 6 (0-14)U (p<0.0001). Maximum, mean, and standard deviation of blood glucose level on the hemodialysis and non-hemodialysis days did not change after teneligliptin administration. However, minimum blood glucose level was significantly elevated on the hemodialysis day after teneligliptin administration (from 3.9±1.0mmol/L to 4.4±0.9mmol/L, p=0.040). The incidence of asymptomatic hypoglycemia on the hemodialysis day detected by CGM significantly decreased from 38.1% to 19.0% (p=0.049). Teneligliptin may contribute toward reducing the total daily insulin dose and preventing hypoglycemic events on the hemodialysis day in type 2 diabetes mellitus patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. A dose-ranging study evaluating once-daily oral administration of the factor Xa inhibitor rivaroxaban in the treatment of patients with acute symptomatic deep vein thrombosis: the Einstein-DVT Dose-Ranging Study.

    PubMed

    Buller, Harry R; Lensing, Anthonie W A; Prins, Martin H; Agnelli, Giancarlo; Cohen, Alexander; Gallus, Alexander S; Misselwitz, Frank; Raskob, Gary; Schellong, Sebastian; Segers, Annelise

    2008-09-15

    We performed a randomized dose-ranging study, double-blind for rivaroxaban doses and open-label for the comparator (low-molecular-weight heparin followed by vitamin K antagonists) to assess the optimal dose of rivaroxaban for the treatment of deep vein thrombosis. A total of 543 patients with acute deep-venous thrombosis received rivaroxaban 20, 30, or 40 mg once daily or comparator. Treatment lasted for 84 days. The primary efficacy outcome was the 3-month incidence of the composite of symptomatic venous thromboembolic complications and asymptomatic deterioration in thrombotic burden as assessed by comparison of ultrasound and perfusion lung scanning at day 84 with baseline. The main safety outcome was the composite of major bleeding and clinically relevant nonmajor bleeding. A total of 449 (83%) of the 543 patients could be included in the per-protocol population. The primary efficacy outcome occurred in 6.1%, 5.4%, and 6.6% of the rivaroxaban 20-, 30-, and 40-mg treatment groups, respectively, and in 9.9% of those receiving standard therapy. The main safety outcome occurred in 5.9%, 6.0%, and 2.2% of the rivaroxaban 20-, 30-, and 40-mg treatment groups, respectively, and in 8.8% of those receiving standard therapy. These results with simple fixed-dose oral regimens justify phase 3 evaluations (www.ClinicalTrials.gov no.NCT00395772).

  3. Verification of calculated skin doses in postmastectomy helical tomotherapy.

    PubMed

    Ito, Shima; Parker, Brent C; Levine, Renee; Sanders, Mary Ella; Fontenot, Jonas; Gibbons, John; Hogstrom, Kenneth

    2011-10-01

    To verify the accuracy of calculated skin doses in helical tomotherapy for postmastectomy radiation therapy (PMRT). In vivo thermoluminescent dosimeters (TLDs) were used to measure the skin dose at multiple points in each of 14 patients throughout the course of treatment on a TomoTherapy Hi·Art II system, for a total of 420 TLD measurements. Five patients were evaluated near the location of the mastectomy scar, whereas 9 patients were evaluated throughout the treatment volume. The measured dose at each location was compared with calculations from the treatment planning system. The mean difference and standard error of the mean difference between measurement and calculation for the scar measurements was -1.8% ± 0.2% (standard deviation [SD], 4.3%; range, -11.1% to 10.6%). The mean difference and standard error of the mean difference between measurement and calculation for measurements throughout the treatment volume was -3.0% ± 0.4% (SD, 4.7%; range, -18.4% to 12.6%). The mean difference and standard error of the mean difference between measurement and calculation for all measurements was -2.1% ± 0.2% (standard deviation, 4.5%: range, -18.4% to 12.6%). The mean difference between measured and calculated TLD doses was statistically significant at two standard deviations of the mean, but was not clinically significant (i.e., was <5%). However, 23% of the measured TLD doses differed from the calculated TLD doses by more than 5%. The mean of the measured TLD doses agreed with TomoTherapy calculated TLD doses within our clinical criterion of 5%. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Verification of Calculated Skin Doses in Postmastectomy Helical Tomotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ito, Shima; Parker, Brent C., E-mail: bcparker@marybird.com; Mary Bird Perkins Cancer Center, Baton Rouge, LA

    2011-10-01

    Purpose: To verify the accuracy of calculated skin doses in helical tomotherapy for postmastectomy radiation therapy (PMRT). Methods and Materials: In vivo thermoluminescent dosimeters (TLDs) were used to measure the skin dose at multiple points in each of 14 patients throughout the course of treatment on a TomoTherapy Hi.Art II system, for a total of 420 TLD measurements. Five patients were evaluated near the location of the mastectomy scar, whereas 9 patients were evaluated throughout the treatment volume. The measured dose at each location was compared with calculations from the treatment planning system. Results: The mean difference and standard errormore » of the mean difference between measurement and calculation for the scar measurements was -1.8% {+-} 0.2% (standard deviation [SD], 4.3%; range, -11.1% to 10.6%). The mean difference and standard error of the mean difference between measurement and calculation for measurements throughout the treatment volume was -3.0% {+-} 0.4% (SD, 4.7%; range, -18.4% to 12.6%). The mean difference and standard error of the mean difference between measurement and calculation for all measurements was -2.1% {+-} 0.2% (standard deviation, 4.5%: range, -18.4% to 12.6%). The mean difference between measured and calculated TLD doses was statistically significant at two standard deviations of the mean, but was not clinically significant (i.e., was <5%). However, 23% of the measured TLD doses differed from the calculated TLD doses by more than 5%. Conclusions: The mean of the measured TLD doses agreed with TomoTherapy calculated TLD doses within our clinical criterion of 5%.« less

  5. Immunogenicity and Tolerability to Human Papillomavirus-like Particle Vaccine in Girls and Young Women with Inflammatory Bowel Disease

    PubMed Central

    Jacobson, Denise L.; Bousvaros, Athos; Ashworth, Lori; Carey, Rebecca; Shrier, Lydia A.; Burchett, Sandra K.; Renna, Harmony; Lu, Ying

    2013-01-01

    Background Female patients receiving immunosuppressive therapy may be at increased risk for human papillomavirus (HPV) infection and cervical neoplasia. Methods We administered the 3-dose HPV vaccine Gardasil® to 37 females aged 9-26 years with inflammatory bowel disease (IBD) prescribed immunosuppressive therapy (prospective cohort). Geometric mean titers (GMT) in milli-Merck (mMu/mL) units were determined before dose 1 and one month after dose 3 by competitive Luminex immunoassay (cLIA) and qualitatively compared to healthy females of similar age from Merck’s database. Side effects and adverse events were evaluated. Concurrently, in 15 similar IBD patients previously vaccinated by their primary care provider we assessed antibody titers by cLIA and total IgG LIA after dose 3 of vaccine (range 0.5 to 27 months). Results The mean age of prospective patients was 15 years with 51% on anti-TNF therapy and 49% on immunomodulators: 33 of 37 completed all three doses. Seropositivity after dose 3 was 100% for types 6, 11 and 16 and 96% for type 18. GMT for HPV 6, 11, 16 and 18 was 1080, 1682, 3975 and 858, respectively, and did not qualitatively differ from healthy females. No serious adverse events were attributable to the vaccine. In the previously vaccinated cohort, seropositivity was 100% for types 6, 11, and 16, and 40% for type 18 by cLIA (93% for HPV18 by IgG LIA). Titers decreased with time since dose 3. Conclusions In this small study of IBD patients prescribed immunosuppressive therapy, Gardasil® was immunogenic and there were no clinically significant vaccine-associated adverse events. PMID:23567780

  6. Treatment dose-response in amblyopia therapy: the Monitored Occlusion Treatment of Amblyopia Study (MOTAS).

    PubMed

    Stewart, Catherine E; Moseley, Merrick J; Stephens, David A; Fielder, Alistair R

    2004-09-01

    Amblyopia is the commonest visual disorder of childhood. Yet the contributions of the two principal treatments (spectacle wear and occlusion) to outcome are unknown. This study was undertaken to investigate the dose-response relationship of amblyopia therapy. The study comprised three distinct phases: baseline, in which repeat measures of visual function were undertaken to confirm the initial visual deficit; refractive adaptation: an 18-week period of spectacle wear with six weekly measurements of logarithm of the minimum angle of resolution (logMAR) visual acuity; occlusion: in which participants were prescribed 6 hours of "patching" per day. In the latter phase, occlusion was objectively monitored and logMAR visual acuity recorded at 2-week intervals until any observed gains had ceased. Data were obtained from 94 participants (mean age, 5.1 +/- 1.4 years) with amblyopia associated with strabismus (n = 34), anisometropia (n = 23), and both anisometropia and strabismus (n = 37). Eighty-six underwent refractive adaptation. Average concordance with patching was 48%. The relationship between logMAR visual acuity gain and total occlusion dose was monotonic and linear. Increasing dose rate beyond 2 h/d hastened the response but did not improve outcome. More than 80% of the improvement during occlusion occurred within 6 weeks. Treatment outcome was significantly better for children younger than 4 years (n = 17) than in those older than 6 years (n = 24; P = 0.0014). Continuous objective monitoring of the amount of patching therapy received has provided insight into the dose-response relationship of occlusion therapy for amblyopia. Patching is most effective within the first few weeks of treatment, even for those in receipt of a relatively small dose. Further studies are needed to elucidate the neural basis for the dose-response functions. Copyright Association for Research in Vision and Ophthalmology

  7. Assessing the uncertainty in a normal tissue complication probability difference (∆NTCP): radiation-induced liver disease (RILD) in liver tumour patients treated with proton vs X-ray therapy.

    PubMed

    Kobashi, Keiji; Prayongrat, Anussara; Kimoto, Takuya; Toramatsu, Chie; Dekura, Yasuhiro; Katoh, Norio; Shimizu, Shinichi; Ito, Yoichi M; Shirato, Hiroki

    2018-03-01

    Modern radiotherapy technologies such as proton beam therapy (PBT) permit dose escalation to the tumour and minimize unnecessary doses to normal tissues. To achieve appropriate patient selection for PBT, a normal tissue complication probability (NTCP) model can be applied to estimate the risk of treatment-related toxicity relative to X-ray therapy (XRT). A methodology for estimating the difference in NTCP (∆NTCP), including its uncertainty as a function of dose to normal tissue, is described in this study using the Delta method, a statistical method for evaluating the variance of functions, considering the variance-covariance matrix. We used a virtual individual patient dataset of radiation-induced liver disease (RILD) in liver tumour patients who were treated with XRT as a study model. As an alternative option for individual patient data, dose-bin data, which consists of the number of patients who developed toxicity in each dose level/bin and the total number of patients in that dose level/bin, are useful for multi-institutional data sharing. It provides comparable accuracy with individual patient data when using the Delta method. With reliable NTCP models, the ∆NTCP with uncertainty might potentially guide the use of PBT; however, clinical validation and a cost-effectiveness study are needed to determine the appropriate ∆NTCP threshold.

  8. Assessing the uncertainty in a normal tissue complication probability difference (∆NTCP): radiation-induced liver disease (RILD) in liver tumour patients treated with proton vs X-ray therapy

    PubMed Central

    Kobashi, Keiji; Kimoto, Takuya; Toramatsu, Chie; Dekura, Yasuhiro; Katoh, Norio; Shimizu, Shinichi; Ito, Yoichi M; Shirato, Hiroki

    2018-01-01

    Abstract Modern radiotherapy technologies such as proton beam therapy (PBT) permit dose escalation to the tumour and minimize unnecessary doses to normal tissues. To achieve appropriate patient selection for PBT, a normal tissue complication probability (NTCP) model can be applied to estimate the risk of treatment-related toxicity relative to X-ray therapy (XRT). A methodology for estimating the difference in NTCP (∆NTCP), including its uncertainty as a function of dose to normal tissue, is described in this study using the Delta method, a statistical method for evaluating the variance of functions, considering the variance–covariance matrix. We used a virtual individual patient dataset of radiation-induced liver disease (RILD) in liver tumour patients who were treated with XRT as a study model. As an alternative option for individual patient data, dose-bin data, which consists of the number of patients who developed toxicity in each dose level/bin and the total number of patients in that dose level/bin, are useful for multi-institutional data sharing. It provides comparable accuracy with individual patient data when using the Delta method. With reliable NTCP models, the ∆NTCP with uncertainty might potentially guide the use of PBT; however, clinical validation and a cost-effectiveness study are needed to determine the appropriate ∆NTCP threshold. PMID:29538699

  9. Safety and Efficacy of Stereotactic Ablative Radiation Therapy for Renal Cell Carcinoma Extracranial Metastases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Chiachien Jake; Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas; Christie, Alana

    Purpose: Renal cell carcinoma is refractory to conventional radiation therapy but responds to higher doses per fraction. However, the dosimetric data and clinical factors affecting local control (LC) are largely unknown. We aimed to evaluate the safety and efficacy of stereotactic ablative radiation therapy (SAbR) for extracranial renal cell carcinoma metastases. Methods and Materials: We reviewed 175 metastatic lesions from 84 patients treated with SAbR between 2005 and 2015. LC and toxicity after SAbR were assessed with Response Evaluation Criteria in Solid Tumors (RECIST) version 1.1 and Common Terminology Criteria for Adverse Events (CTCAE) version 4.0. Predictors of local failure weremore » analyzed with χ{sup 2}, Kaplan-Meier, and log-rank tests. Results: In most cases (74%), SAbR was delivered with total doses of 40 to 60 Gy, 30 to 54 Gy, and 20 to 40 Gy in 5 fractions, 3 fractions, and a single fraction, respectively. The median biologically effective dose (BED) using the universal survival model was 134.5 Gy. The 1-year LC rate after SAbR was 91.2% (95% confidence interval, 84.9%-95.0%; median follow-up, 16.7 months). Local failures were associated with prior radiation therapy (hazard ratio [HR], 10.49; P<.0001), palliative-intent radiation therapy (HR, 4.63; P=.0189), spinal location (HR, 5.36; P=.0041), previous systemic therapy status (0-1 vs >1; HR, 3.52; P=.0217), and BED <115 Gy (HR, 3.45; P=.0254). Dose received by 99% of the target volume was the strongest dosimetric predictor for LC. Upon multivariate analysis, dose received by 99% of the target volume greater than BED of 98.7 Gy and systemic therapy status remained significant (HR, 0.12 and 3.64, with P=.0014 and P=.0472, respectively). Acute and late grade 3 toxicities attributed to SAbR were observed in 3 patients (1.7%) and 5 patients (2.9%), respectively. Conclusions: SAbR demonstrated excellent LC of metastatic renal cell carcinoma with a favorable safety profile when an adequate dose and coverage were applied. Multimodality treatment with surgery should be considered for reirradiation or vertebral metastasis. A higher radiation dose may be required in patients who received previous systemic therapies.« less

  10. Treatment of traumatic infra orbital nerve paresthesia

    PubMed Central

    Lone, Parveen Akhter; Singh, R. K.; Pal, U. S.

    2012-01-01

    This study was done to find out the role of topiramate therapy in infraorbital nerve paresthesia after miniplate fixation in zygomatic complxex fractures. A total 2 cases of unilateral zygomatic complex fracture, 2-3 weeks old with infra orbital nerve paresthesia were slected. Open reduction and plating was done in frontozygomaticregion. Antiepileptic drug tab topiramate was given in therapeutic doses and dose was increased slowly until functional recovery was noticed. PMID:23833503

  11. Palifermin: new drug. Prevention of oral mucositis: inappropriate evaluation.

    PubMed

    2007-08-01

    (1) Patients treated with high-dose chemotherapy combined with total body irradiation (myeloablative therapy) often develop oral mucositis. Prevention is based mainly on sucking ice during chemotherapy. (2) Palifermin is a growth factor marketed for the prevention of severe oral mucositis in adults with malignant haemopathies who are receiving myeloablative therapy followed by peripheral stem cell autografting. (3) Palifermin has not been compared with sucking ice, despite the efficacy of this simple treatment. (4) In a randomised placebo-controlled double-blind trial involving 212 adult patients treated with high-dose chemotherapy and total body irradiation, palifermin reduced the incidence of severe oral mucositis (63% versus 98%) and its duration (about 3 days versus 9 days). The myeloablative regimen used in this trial is not that commonly used in Europe. The efficacy of palifermin during less aggressive regimens, which cause less severe oral mucositis, is not known. (5) The main adverse events noted in clinical trials were erythema and cutaneous oedema. It is not known whether palifermin increases the long-term risk of cancer. (6) Treatment with palifermin is expensive, 4800.00 euros in France); the optimal dosing schedule is not known and the unit dose chosen by the manufacturer is wastefully large. (7) In practice, it remains to be demonstrated that palifermin is more effective than simply sucking ice.

  12. SU-F-T-76: Total Skin Electron Therapy: An-End-To-End Examination of the Absolute Dosimetry with a Rando Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cui, G; Ha, J; Zhou, S

    Purpose: To examine and validate the absolute dose for total skin electron therapy (TSET) through an end-to-end test with a Rando phantom using optically stimulated luminescent dosimeters (OSLDs) and EBT3 radiochromic films. Methods: A Varian Trilogy linear accelerator equipped with the special procedure 6 MeV HDTSe- was used to perform TSET irradiations using a modified Stanford 6-dual-field technique. The absolute dose was calibrated using a Markus ion chamber at a reference depth of 1.3cm at 100 cm SSD with a field size of 36 × 36 cm at the isocenter in solid water slabs. The absolute dose was cross validatedmore » by a farmer ion chamber. Then the dose rate in the unit of cGy/Mu was calibrated using the Markus chamber at the treatment position. OSLDs were used to independently verify the dose using the calibrated dose rate. Finally, a patient treatment plan (200 cGy/cycle) was delivered in the QA mode to a Rando phantom, which had 16 pairs of OSLDs and EBT3 films taped onto its surface at different anatomical positions. The doses recorded were read out to validate the absolute dosimetry for TSET. Results: The OSLD measurements were within 7% agreement with the planned dose except the shoulder areas, where the doses recorded were 23% lower on average than those of the planned. The EBT3 film measurements were within 10% agreement with the planned dose except the shoulder and the scalp vertex areas, where the respective doses recorded were 18% and 14% lower on average than those of the planned. The OSLDs gave more consistent dose measurements than those of the EBT3 films. Conclusion: The absolute dosimetry for TSET was validated by an end-to-end test with a Rando phantom using the OSLDs and EBT3 films. The beam calibration and monitor unit calculations were confirmed.« less

  13. Site-specific range uncertainties caused by dose calculation algorithms for proton therapy

    NASA Astrophysics Data System (ADS)

    Schuemann, J.; Dowdell, S.; Grassberger, C.; Min, C. H.; Paganetti, H.

    2014-08-01

    The purpose of this study was to assess the possibility of introducing site-specific range margins to replace current generic margins in proton therapy. Further, the goal was to study the potential of reducing margins with current analytical dose calculations methods. For this purpose we investigate the impact of complex patient geometries on the capability of analytical dose calculation algorithms to accurately predict the range of proton fields. Dose distributions predicted by an analytical pencil-beam algorithm were compared with those obtained using Monte Carlo (MC) simulations (TOPAS). A total of 508 passively scattered treatment fields were analyzed for seven disease sites (liver, prostate, breast, medulloblastoma-spine, medulloblastoma-whole brain, lung and head and neck). Voxel-by-voxel comparisons were performed on two-dimensional distal dose surfaces calculated by pencil-beam and MC algorithms to obtain the average range differences and root mean square deviation for each field for the distal position of the 90% dose level (R90) and the 50% dose level (R50). The average dose degradation of the distal falloff region, defined as the distance between the distal position of the 80% and 20% dose levels (R80-R20), was also analyzed. All ranges were calculated in water-equivalent distances. Considering total range uncertainties and uncertainties from dose calculation alone, we were able to deduce site-specific estimations. For liver, prostate and whole brain fields our results demonstrate that a reduction of currently used uncertainty margins is feasible even without introducing MC dose calculations. We recommend range margins of 2.8% + 1.2 mm for liver and prostate treatments and 3.1% + 1.2 mm for whole brain treatments, respectively. On the other hand, current margins seem to be insufficient for some breast, lung and head and neck patients, at least if used generically. If no case specific adjustments are applied, a generic margin of 6.3% + 1.2 mm would be needed for breast, lung and head and neck treatments. We conclude that the currently used generic range uncertainty margins in proton therapy should be redefined site specific and that complex geometries may require a field specific adjustment. Routine verifications of treatment plans using MC simulations are recommended for patients with heterogeneous geometries.

  14. Oxygen and Perfusion Kinetics in Response to Fractionated Radiation Therapy in FaDu Head and Neck Cancer Xenografts Are Related to Treatment Outcome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Fangyao; Vishwanath, Karthik; Salama, Joseph K.

    Purpose: To test whether oxygenation kinetics correlate with the likelihood for local tumor control after fractionated radiation therapy. Methods and Materials: We used diffuse reflectance spectroscopy to noninvasively measure tumor vascular oxygenation and total hemoglobin concentration associated with radiation therapy of 5 daily fractions (7.5, 9, or 13.5 Gy/d) in FaDu xenografts. Spectroscopy measurements were obtained immediately before each daily radiation fraction and during the week after radiation therapy. Oxygen saturation and total hemoglobin concentration were computed using an inverse Monte Carlo model. Results: First, oxygenation kinetics during and after radiation therapy, but before tumor volumes changed, were associated with localmore » tumor control. Locally controlled tumors exhibited significantly faster increases in oxygenation after radiation therapy (days 12-15) compared with tumors that recurred locally. Second, within the group of tumors that recurred, faster increases in oxygenation during radiation therapy (day 3-5 interval) were correlated with earlier recurrence times. An area of 0.74 under the receiver operating characteristic curve was achieved when classifying the local control tumors from all irradiated tumors using the oxygen kinetics with a logistic regression model. Third, the rate of increase in oxygenation was radiation dose dependent. Radiation doses ≤9.5 Gy/d did not initiate an increase in oxygenation, whereas 13.5 Gy/d triggered significant increases in oxygenation during and after radiation therapy. Conclusions: Additional confirmation is required in other tumor models, but these results suggest that monitoring tumor oxygenation kinetics could aid in the prediction of local tumor control after radiation therapy.« less

  15. A randomized phase II trial evaluating different schedules of zoledronic acid on bone mineral density in patients with prostate cancer beginning androgen deprivation therapy.

    PubMed

    Lang, Joshua M; Wallace, Marianne; Becker, Jordan T; Eickhoff, Jens C; Buehring, Bjoern; Binkley, Neil; Staab, Mary Jane; Wilding, George; Liu, Glenn; Malkovsky, Miroslav; McNeel, Douglas G

    2013-12-01

    To assess the effects of timing and schedule of zoledronic acid (ZA) administration on bone mineral density (BMD) in patients beginning androgen deprivation therapy (ADT) for the treatment of recurrent prostate cancer. In this randomized, 3-arm trial, we evaluated changes in BMD after 3 different ZA administration schedules in men with recurrent prostate cancer who were beginning ADT. Forty-four patients were enrolled and randomized to receive a single dose of ZA given 1 week before beginning ADT (arm 1), a single dose of ZA given 6 months after beginning ADT (arm 2), or monthly administration of ZA starting 6 months after beginning ADT, for a total of 6 doses (arm 3). Patients who received ZA before ADT had a significant improvement in BMD at the total proximal femur and trochanter after 6 months compared with the other groups. In addition, only patients in the arm that received multiple doses improved lumbar spine BMD while on ADT, with these findings persisting to 24 months. However, this group also experienced more grade 1 adverse events. Analysis of these data suggests that ZA administration before initiation of ADT was superior to treatment 6 months after starting ADT in maintaining BMD. In addition, monthly ZA administration can increase BMD above baseline but is associated with more adverse events. Further study is needed to examine whether the timing and frequency of ZA therapy in patients on ADT can reduce fracture risk. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Adverse Drug Reactions and Expected Effects to Therapy with Subcutaneous Mistletoe Extracts (Viscum album L.) in Cancer Patients

    PubMed Central

    Steele, Megan L.; Happe, Antje; Kröz, Matthias; Matthes, Harald; Schad, Friedemann

    2014-01-01

    Background. In Europe, mistletoe extracts are widely used as a complementary cancer therapy. We assessed the safety of subcutaneous mistletoe as a conjunctive therapy in cancer patients within an anthroposophic medicine setting in Germany. Methods. A multicentre, observational study was performed within the Network Oncology. Suspected mistletoe adverse drug reactions (ADRs) were described by frequency, causality, severity, and seriousness. Potential risk factors, dose relationships and drug-drug interactions were investigated. Results. Of 1923 cancer patients treated with subcutaneous mistletoe extracts, 283 patients (14.7%) reported 427 expected effects (local reactions <5 cm and increased body temperature <38°C). ADRs were documented in 162 (8.4%) patients who reported a total of 264 events. ADRs were mild (50.8%), moderate (45.1%), or severe (4.2%). All were nonserious. Logistic regression analysis revealed that expected effects were more common in females, while immunoreactivity decreased with increasing age and tumour stage. No risk factors were identified for ADRs. ADR frequency increased as mistletoe dose increased, while fewer ADRs occurred during mistletoe therapy received concurrent with conventional therapies. Conclusion. The results of this study indicate that mistletoe therapy is safe. ADRs were mostly mild to moderate in intensity and appear to be dose-related and explained by the immune-stimulating, pharmacological activity of mistletoe. PMID:24672577

  17. A comparative analysis of 3D conformal deep inspiratory–breath hold and free-breathing intensity-modulated radiation therapy for left-sided breast cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reardon, Kelli A.; Read, Paul W.; Morris, Monica M.

    2013-07-01

    Patients undergoing radiation for left-sided breast cancer have increased rates of coronary artery disease. Free-breathing intensity-modulated radiation therapy (FB-IMRT) and 3-dimensional conformal deep inspiratory–breath hold (3D-DIBH) reduce cardiac irradiation. The purpose of this study is to compare the dose to organs at risk in FB-IMRT vs 3D-DIBH for patients with left-sided breast cancer. Ten patients with left-sided breast cancer had 2 computed tomography scans: free breathing and voluntary DIBH. Optimization of the IMRT plan was performed on the free-breathing scan using 6 noncoplanar tangential beams. The 3D-DIBH plan was optimized on the DIBH scan and used standard tangents. Mean volumesmore » of the heart, the left anterior descending coronary artery (LAD), the total lung, and the right breast receiving 5% to 95% (5% increments) of the prescription dose were calculated. Mean volumes of the heart and the LAD were lower (p<0.05) in 3D-DIBH for volumes receiving 5% to 80% of the prescription dose for the heart and 5% for the LAD. Mean dose to the LAD and heart were lower in 3D-DIBH (p≤0.01). Mean volumes of the total lung were lower in FB-IMRT for dose levels 20% to 75% (p<0.05), but mean dose was not different. Mean volumes of the right breast were not different for any dose; however, mean dose was lower for 3D-DIBH (p = 0.04). 3D-DIBH is an alternative approach to FB-IMRT that provides a clinically equivalent treatment for patients with left-sided breast cancer while sparing organs at risk with increased ease of implementation.« less

  18. Monte Carlo based dosimetry for neutron capture therapy of brain tumors

    NASA Astrophysics Data System (ADS)

    Zaidi, Lilia; Belgaid, Mohamed; Khelifi, Rachid

    2016-11-01

    Boron Neutron Capture Therapy (BNCT) is a biologically targeted, radiation therapy for cancer which combines neutron irradiation with a tumor targeting agent labeled with a boron10 having a high thermal neutron capture cross section. The tumor area is subjected to the neutron irradiation. After a thermal neutron capture, the excited 11B nucleus fissions into an alpha particle and lithium recoil nucleus. The high Linear Energy Transfer (LET) emitted particles deposit their energy in a range of about 10μm, which is of the same order of cell diameter [1], at the same time other reactions due to neutron activation with body component are produced. In-phantom measurement of physical dose distribution is very important for BNCT planning validation. Determination of total absorbed dose requires complex calculations which were carried out using the Monte Carlo MCNP code [2].

  19. Comparison of a new noncoplanar intensity-modulated radiation therapy technique for craniospinal irradiation with 3 coplanar techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, Anders T., E-mail: andehans@rm.dk; Lukacova, Slavka; Lassen-Ramshad, Yasmin

    2015-01-01

    When standard conformal x-ray technique for craniospinal irradiation is used, it is a challenge to achieve satisfactory dose coverage of the target including the area of the cribriform plate, while sparing organs at risk. We present a new intensity-modulated radiation therapy (IMRT), noncoplanar technique, for delivering irradiation to the cranial part and compare it with 3 other techniques and previously published results. A total of 13 patients who had previously received craniospinal irradiation with standard conformal x-ray technique were reviewed. New treatment plans were generated for each patient using the noncoplanar IMRT-based technique, a coplanar IMRT-based technique, and a coplanarmore » volumetric-modulated arch therapy (VMAT) technique. Dosimetry data for all patients were compared with the corresponding data from the conventional treatment plans. The new noncoplanar IMRT technique substantially reduced the mean dose to organs at risk compared with the standard radiation technique. The 2 other coplanar techniques also reduced the mean dose to some of the critical organs. However, this reduction was not as substantial as the reduction obtained by the noncoplanar technique. Furthermore, compared with the standard technique, the IMRT techniques reduced the total calculated radiation dose that was delivered to the normal tissue, whereas the VMAT technique increased this dose. Additionally, the coverage of the target was significantly improved by the noncoplanar IMRT technique. Compared with the standard technique, the coplanar IMRT and the VMAT technique did not improve the coverage of the target significantly. All the new planning techniques increased the number of monitor units (MU) used—the noncoplanar IMRT technique by 99%, the coplanar IMRT technique by 122%, and the VMAT technique by 26%—causing concern for leak radiation. The noncoplanar IMRT technique covered the target better and decreased doses to organs at risk compared with the other techniques. All the new techniques increased the number of MU compared with the standard technique.« less

  20. TH-AB-BRB-04: Quality Assurance for Advanced Digital Linac Implementations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, V.

    2016-06-15

    Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapymore » involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.« less

  1. TH-AB-BRB-00: Research Opportunities with Digital Linear Accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2016-06-15

    Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapymore » involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.« less

  2. Long-term Results of Carbon Ion Radiation Therapy for Locally Advanced or Unfavorably Located Choroidal Melanoma: Usefulness of CT-based 2-Port Orthogonal Therapy for Reducing the Incidence of Neovascular Glaucoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toyama, Shingo; Department of Heavy Particle Therapy and Radiation Oncology, Faculty of Medicine, Saga University, Saga; Tsuji, Hiroshi, E-mail: h_tsuji@nirs.go.jp

    2013-06-01

    Purpose: To determine the long-term results of carbon ion radiation therapy (C-ion RT) in patients with choroidal melanoma, and to assess the usefulness of CT-based 2-port irradiation in reducing the risk of neovascular glaucoma (NVG). Methods and Materials: Between January 2001 and February 2012, a total of 116 patients with locally advanced or unfavorably located choroidal melanoma received CT-based C-ion RT. Of these patients, 114 were followed up for more than 6 months and their data analyzed. The numbers of T3 and T2 patients (International Union Against Cancer [UICC], 5th edition) were 106 and 8, respectively. The total dose ofmore » C-ion RT varied from 60 to 85 GyE, with each dose given in 5 fractions. Since October 2005, 2-port therapy (51 patients) has been used in an attempt to reduce the risk of NVG. A dose-volume histogram analysis was also performed in 106 patients. Results: The median follow-up was 4.6 years (range, 0.5-10.6 years). The 5-year overall survival, cause-specific survival, local control, distant metastasis-free survival, and eye retention rates were 80.4% (95% confidence interval 89.0%-71.8%), 82.2% (90.6%-73.8%), 92.8% (98.5%-87.1%), 72.1% (81.9%-62.3%), and 92.8% (98.1%-87.5%), respectively. The overall 5-year NVG incidence rate was 35.9% (25.9%-45.9%) and that of 1-port group and 2-port group were 41.6% (29.3%-54.0%) and 13.9% (3.2%-24.6%) with statistically significant difference (P<.001). The dose-volume histogram analysis showed that the average irradiated volume of the iris-ciliary body was significantly lower in the non-NVG group than in the NVG group at all dose levels, and significantly lower in the 2-port group than in the 1-port group at high dose levels. Conclusions: The long-term results of C-ion RT for choroidal melanoma are satisfactory. CT-based 2-port C-ion RT can be used to reduce the high-dose irradiated volume of the iris-ciliary body and the resulting risk of NVG.« less

  3. Simultaneous integrated vs. sequential boost in VMAT radiotherapy of high-grade gliomas.

    PubMed

    Farzin, Mostafa; Molls, Michael; Astner, Sabrina; Rondak, Ina-Christine; Oechsner, Markus

    2015-12-01

    In 20 patients with high-grade gliomas, we compared two methods of planning for volumetric-modulated arc therapy (VMAT): simultaneous integrated boost (SIB) vs. sequential boost (SEB). The investigation focused on the analysis of dose distributions in the target volumes and the organs at risk (OARs). After contouring the target volumes [planning target volumes (PTVs) and boost volumes (BVs)] and OARs, SIB planning and SEB planning were performed. The SEB method consisted of two plans: in the first plan the PTV received 50 Gy in 25 fractions with a 2-Gy dose per fraction. In the second plan the BV received 10 Gy in 5 fractions with a dose per fraction of 2 Gy. The doses of both plans were summed up to show the total doses delivered. In the SIB method the PTV received 54 Gy in 30 fractions with a dose per fraction of 1.8 Gy, while the BV received 60 Gy in the same fraction number but with a dose per fraction of 2 Gy. All of the OARs showed higher doses (Dmax and Dmean) in the SEB method when compared with the SIB technique. The differences between the two methods were statistically significant in almost all of the OARs. Analysing the total doses of the target volumes we found dose distributions with similar homogeneities and comparable total doses. Our analysis shows that the SIB method offers advantages over the SEB method in terms of sparing OARs.

  4. Skin dose differences between intensity-modulated radiation therapy and volumetric-modulated arc therapy and between boost and integrated treatment regimens for treating head and neck and other cancer sites in patients.

    PubMed

    Penoncello, Gregory P; Ding, George X

    2016-01-01

    The purpose of this study was (1) to evaluate dose to skin between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) treatment techniques for target sites in the head and neck, pelvis, and brain and (2) to determine if the treatment dose and fractionation regimen affect the skin dose between traditional sequential boost and integrated boost regimens for patients with head and neck cancer. A total of 19 patients and 48 plans were evaluated. The Eclipse (v11) treatment planning system was used to plan therapy in 9 patients with head and neck cancer, 5 patients with prostate cancer, and 5 patients with brain cancer with VMAT and static-field IMRT. The mean skin dose and the maximum dose to a contiguous volume of 2cm(3) for head and neck plans and brain plans and a contiguous volume of 5cm(3) for pelvis plans were compared for each treatment technique. Of the 9 patients with head and neck cancer, 3 underwent an integrated boost regimen. One integrated boost plan was replanned with IMRT and VMAT using a traditional boost regimen. For target sites located in the head and neck, VMAT reduced the mean dose and contiguous hot spot most noticeably in the shoulder region by 5.6% and 5.4%, respectively. When using an integrated boost regimen, the contiguous hot spot skin dose in the shoulder was larger on average than a traditional boost pattern by 26.5% and the mean skin dose was larger by 1.7%. VMAT techniques largely decrease the contiguous hot spot in the skin in the pelvis by an average of 36% compared with IMRT. For the same target coverage, VMAT can reduce the skin dose in all the regions of the body, but more noticeably in the shoulders in patients with head and neck and pelvis cancer. We also found that using integrated boost regimens in patients with head and neck cancer leads to higher shoulder skin doses compared with traditional boost regimens. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  5. Simultaneous integrated boost-intensity modulated radiation therapy for inoperable hepatocellular carcinoma.

    PubMed

    Kim, Tae Hyun; Park, Joong-Won; Kim, Yeon-Joo; Kim, Bo Hyun; Woo, Sang Myung; Moon, Sung Ho; Kim, Sang Soo; Lee, Woo Jin; Kim, Dae Yong; Kim, Chang-Min

    2014-10-01

    The aim of this work was to evaluate the clinical efficacy and safety of simultaneous integrated boost-intensity modulated radiation therapy (SIB-IMRT) in patients with inoperable hepatocellular carcinoma (HCC). A total of 53 patients with inoperable HCC underwent SIB-IMRT using two dose-fractionation schemes, depending on the proximity of gastrointestinal structures. The 41 patients in the low dose-fractionation (LD) group, with internal target volume (ITV) < 1 cm from gastrointestinal structures, received total doses of 55 and 44 Gy in 22 fractions to planning target volume 1 (PTV1) and 2 (PTV2), respectively. The 12 patients in the high dose-fractionation (HD) group, with ITV ≥ 1 cm from gastrointestinal structures, received total doses of 66 and 55 Gy in 22 fractions to the PTV1 and PTV2, respectively. Overall, treatment was well tolerated, with no grade > 3 toxicity. The LD group had larger sized tumors (median: 6 vs. 3.4 cm) and greater frequencies of vascular invasion (80.6 vs. 16.7 %) than patients in the HD group (p < 0.05 each). The median overall survival (OS) was 25.1 mKonzept ist machbar und sicheronths and the actuarial 2-year local progression-free survival (LPFS), relapse-free survival (RFS), and OS rates were 67.3, 14.7, and 54.7  %, respectively. The HD group tended to show better tumor response (100 vs. 62.2 %, p = 0.039) and 2-year LPFS (85.7 vs. 59  %, p = 0.119), RFS (38.1 vs. 7.3 %, p = 0.063), and OS (83.3 vs. 44.3 %, p = 0.037) rates than the LD group. Multivariate analysis showed that tumor response was significantly associated with OS. SIB-IMRT is feasible and safe for patients with inoperable HCC.

  6. Cancer risk estimates from radiation therapy for heterotopic ossification prophylaxis after total hip arthroplasty.

    PubMed

    Mazonakis, Michalis; Berris, Theoharris; Lyraraki, Efrossyni; Damilakis, John

    2013-10-01

    Heterotopic ossification (HO) is a frequent complication following total hip arthroplasty. This study was conducted to calculate the radiation dose to organs-at-risk and estimate the probability of cancer induction from radiotherapy for HO prophylaxis. Hip irradiation for HO with a 6 MV photon beam was simulated with the aid of a Monte Carlo model. A realistic humanoid phantom representing an average adult patient was implemented in Monte Carlo environment for dosimetric calculations. The average out-of-field radiation dose to stomach, liver, lung, prostate, bladder, thyroid, breast, uterus, and ovary was calculated. The organ-equivalent-dose to colon, that was partly included within the treatment field, was also determined. Organ dose calculations were carried out using three different field sizes. The dependence of organ doses upon the block insertion into primary beam for shielding colon and prosthesis was investigated. The lifetime attributable risk for cancer development was estimated using organ, age, and gender-specific risk coefficients. For a typical target dose of 7 Gy, organ doses varied from 1.0 to 741.1 mGy by the field dimensions and organ location relative to the field edge. Blocked field irradiations resulted in a dose range of 1.4-146.3 mGy. The most probable detriment from open field treatment of male patients was colon cancer with a high risk of 564.3 × 10(-5) to 837.4 × 10(-5) depending upon the organ dose magnitude and the patient's age. The corresponding colon cancer risk for female patients was (372.2-541.0) × 10(-5). The probability of bladder cancer development was more than 113.7 × 10(-5) and 110.3 × 10(-5) for males and females, respectively. The cancer risk range to other individual organs was reduced to (0.003-68.5) × 10(-5). The risk for cancer induction from radiation therapy for HO prophylaxis after total hip arthroplasty varies considerably by the treatment parameters, organ site in respect to treatment volume and patient's gender and age. The presented risk estimates may be useful in the follow-up studies of irradiated patients.

  7. Immune tolerance improves the efficacy of enzyme replacement therapy in canine mucopolysaccharidosis I

    PubMed Central

    Dickson, Patricia; Peinovich, Maryn; McEntee, Michael; Lester, Thomas; Le, Steven; Krieger, Aimee; Manuel, Hayden; Jabagat, Catherine; Passage, Merry; Kakkis, Emil D.

    2008-01-01

    Mucopolysaccharidoses (MPSs) are lysosomal storage diseases caused by a deficit in the enzymes needed for glycosaminoglycan (GAG) degradation. Enzyme replacement therapy with recombinant human α-l-iduronidase successfully reduces lysosomal storage in canines and humans with iduronidase-deficient MPS I, but therapy usually also induces antibodies specific for the recombinant enzyme that could reduce its efficacy. To understand the potential impact of α-l-iduronidase–specific antibodies, we studied whether inducing antigen-specific immune tolerance to iduronidase could improve the effectiveness of recombinant iduronidase treatment in canines. A total of 24 canines with MPS I were either tolerized to iduronidase or left nontolerant. All canines received i.v. recombinant iduronidase at the FDA-approved human dose or a higher dose for 9–44 weeks. Nontolerized canines developed iduronidase-specific antibodies that proportionally reduced in vitro iduronidase uptake. Immune-tolerized canines achieved increased tissue enzyme levels at either dose in most nonreticular tissues and a greater reduction in tissue GAG levels, lysosomal pathology, and urinary GAG excretion. Tolerized MPS I dogs treated with the higher dose received some further benefit in the reduction of GAGs in tissues, urine, and the heart valve. Therefore, immune tolerance to iduronidase improved the efficacy of enzyme replacement therapy with recombinant iduronidase in canine MPS I and could potentially improve outcomes in patients with MPS I and other lysosomal storage diseases. PMID:18654665

  8. On the MTD paradigm and optimal control for multi-drug cancer chemotherapy.

    PubMed

    Ledzewicz, Urszula; Schättler, Heinz; Gahrooi, Mostafa Reisi; Dehkordi, Siamak Mahmoudian

    2013-06-01

    In standard chemotherapy protocols, drugs are given at maximum tolerated doses (MTD) with rest periods in between. In this paper, we briey discuss the rationale behind this therapy approach and, using as example multidrug cancer chemotherapy with a cytotoxic and cytostatic agent, show that these types of protocols are optimal in the sense of minimizing a weighted average of the number of tumor cells (taken both at the end of therapy and at intermediate times) and the total dose given if it is assumed that the tumor consists of a homogeneous population of chemotherapeutically sensitive cells. A 2-compartment linear model is used to model the pharmacokinetic equations for the drugs.

  9. Delivery confirmation of bolus electron conformal therapy combined with intensity modulated x-ray therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kavanaugh, James A.; Hogstrom, Kenneth R.; Fontenot, Jonas P.

    2013-02-15

    Purpose: The purpose of this study was to demonstrate that a bolus electron conformal therapy (ECT) dose plan and a mixed beam plan, composed of an intensity modulated x-ray therapy (IMXT) dose plan optimized on top of the bolus ECT plan, can be accurately delivered. Methods: Calculated dose distributions were compared with measured dose distributions for parotid and chest wall (CW) bolus ECT and mixed beam plans, each simulated in a cylindrical polystyrene phantom that allowed film dose measurements. Bolus ECT plans were created for both parotid and CW PTVs (planning target volumes) using 20 and 16 MeV beams, respectively,more » whose 90% dose surface conformed to the PTV. Mixed beam plans consisted of an IMXT dose plan optimized on top of the bolus ECT dose plan. The bolus ECT, IMXT, and mixed beam dose distributions were measured using radiographic films in five transverse and one sagittal planes for a total of 36 measurement conditions. Corrections for film dose response, effects of edge-on photon irradiation, and effects of irregular phantom optical properties on the Cerenkov component of the film signal resulted in high precision measurements. Data set consistency was verified by agreement of depth dose at the intersections of the sagittal plane with the five measured transverse planes. For these same depth doses, results for the mixed beam plan agreed with the sum of the individual depth doses for the bolus ECT and IMXT plans. The six mean measured planar dose distributions were compared with those calculated by the treatment planning system for all modalities. Dose agreement was assessed using the 4% dose difference and 0.2 cm distance to agreement. Results: For the combined high-dose region and low-dose region, pass rates for the parotid and CW plans were 98.7% and 96.2%, respectively, for the bolus ECT plans and 97.9% and 97.4%, respectively, for the mixed beam plans. For the high-dose gradient region, pass rates for the parotid and CW plans were 93.1% and 94.62%, respectively, for the bolus ECT plans and 89.2% and 95.1%, respectively, for the mixed beam plans. For all regions, pass rates for the parotid and CW plans were 98.8% and 97.3%, respectively, for the bolus ECT plans and 97.5% and 95.9%, respectively, for the mixed beam plans. For the IMXT component of the mixed beam plans, pass rates for the parotid and CW plans were 93.7% and 95.8%. Conclusions: Bolus ECT and mixed beam therapy dose delivery to the phantom were more accurate than IMXT delivery, adding confidence to the use of planning, fabrication, and delivery for bolus ECT tools either alone or as part of mixed beam therapy. The methodology reported in this work could serve as a basis for future standardization of the commissioning of bolus ECT or mixed beam therapy. When applying this technology to patients, it is recommended that an electron dose algorithm more accurate than the pencil beam algorithm, e.g., a Monte Carlo algorithm or analytical transport such as the pencil beam redefinition algorithm, be used for planning to ensure the desired accuracy.« less

  10. Alterations of nutritional status: impact of chemotherapy and radiation therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Donaldson, S.S.; Lenon, R.A.

    1979-05-01

    The nutritional status of a cancer patient may be affected by the tumor, the chemotherapy and/or radiation therapy directed against the tumor, and by complications associated with that therapy. Chemotherpay-radiotherapy is not confined exclusively to malignant cell populations; thus, normal tissues may also be affected by the therapy and may contribute to specific nutritional problems. Impaired nutrition due to anorexia, mucositis, nausea, vomiting, and diarrhea may be dependent upon the specific chemotherapeutic agent, dose, or schedule utilized. Similar side effects from radiation therapy depend upon the dose, fractionation, and volume irradiated. When combined modality treatment is given the nutritional consequencesmore » may be magnified. Prospective, randomized clinical trials are underway to investigate the efficacy of nutritional support during chemotherapy-radiotherapy on tolerance to treatment, complications from treatment, and response rates to treatment. Preliminary results demonstrate that the administration of total parenteral nutrition is successful in maintaining weight during radiation therapy and chemotherapy, but that weight loss occurs after discontinuation of nutritional support. Thus, longterm evaluation is mandatory to learn the impact of nutritional support on survival, diease-free survival, and complication rates, as well as on the possible prevention of morbidity associated with aggressive chemotherapy-radiation therapy.« less

  11. Recombinant FVIIa (NovoSeven) continuous infusion and total hip replacement in patients with haemophilia and high titre of inhibitors to FVIII: experience of two cases.

    PubMed

    Tagariello, G; De Biasi, E; Gajo, G B; Risato, R; Radossi, P; Davoli, P G; Traldi, A

    2000-09-01

    In this report we describe our experience of total hip replacement in two patients with severe haemophilia A and high titres of inhibitors to FVIII. We used rFVIIa replacement therapy by continuous infusion to perform the surgery. The total amount of rFVIIa used in these two patients was very similar but the manner of administration was quite different. In our experience, it is an advantage to use a higher dose for shorter periods than a lower dose for a longer treatment period. Tranexamic acid by continuous infusion, and parallel saline infusion were useful for good haemostasis and avoided local thrombophlebitis in the side of rFVIIa infusion.

  12. Acute Toxicity Grade 3 and 4 After Irradiation in Children and Adolescents: Results From the IPPARCA Collaboration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pixberg, Caroline; Koch, Raphael; Eich, Hans Theodor, E-mail: Hans.Eich@ukmuenster.de

    Purpose: In the context of oncologic therapy for children, radiation therapy is frequently indicated. This study identified the frequency of and reasons for the development of high-grade acute toxicity and possible sequelae. Materials and Methods: Irradiated children have been prospectively documented since 2001 in the Registry for the Evaluation of Side Effects After Radiation in Childhood and Adolescence (RiSK) database in Germany and since 2008 in the registry for radiation therapy toxicity (RADTOX) in Sweden. Data were collected using standardized, published forms. Toxicity classification was based on Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer criteria. Results: Asmore » of June 2013, 1500 children have been recruited into the RiSK database and 485 into the RADTOX registry leading to an analysis population of 1359 patients (age range 0-18). A total of 18.9% (n=257) of all investigated patients developed high-grade acute toxicity (grades 3/4). High-grade toxicity of the bone marrow was documented for 63.8% (n=201) of those patients, oral mucositis for 7.6% (n=24), and dermatitis for 7.6% (n=24). Patients with high-grade acute toxicity received concomitant chemotherapy more frequently (56%) than patients with no or lower acute toxicity (31.5%). In multivariate analyses, concomitant chemotherapy, diagnosis of Ewing sarcoma, and total radiation dose showed a statistically noticeable effect (P≤.05) on acute toxicity, whereas age, concomitant chemotherapy, Hodgkin lymphoma, Ewing sarcoma, total radiation dose, and acute toxicity influenced the time until maximal late toxicity. Conclusions: Generally, high-grade acute toxicity after irradiation in children and adolescence occurs in a moderate proportion of patients (18.9%). As anticipated, the probability of acute toxicity appeared to depend on the prescribed dose as well as concomitant chemotherapy. The occurrence of chronic toxicity correlates with the prior acute toxicity grade. Age seems to influence the time until maximal late toxicity but not the development of acute toxicity.« less

  13. Fixed-dose combination therapy for the prevention of cardiovascular disease

    PubMed Central

    de Cates, Angharad N; Farr, Matthew RB; Wright, Nicola; Jarvis, Morag C; Rees, Karen; Ebrahim, Shah; Huffman, Mark D

    2014-01-01

    Background Cardiovascular disease (CVD) is the leading cause of death and disability worldwide, yet CVD risk factor control and secondary prevention rates remain low. A fixed-dose combination of blood pressure and cholesterol lowering and antiplatelet treatments into a single pill, or polypill, has been proposed as one strategy to reduce the global burden of CVD by up to 80% given its potential for better adherence and lower costs. Objectives To determine the effectiveness of fixed-dose combination therapy on reducing fatal and non-fatal CVD events and on improving blood pressure and lipid CVD risk factors for both primary and secondary prevention of CVD. We also aimed to determine discontinuation rates, adverse events, health-related quality of life, and costs of fixed-dose combination therapy. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) in The Cochrane Library(2013, Issue 6), MEDLINE Ovid (1946 to week 2 July 2013), EMBASE Ovid (1980 to Week 28 2013), ISI Web of Science (1970 to 19 July 2013), and the Database of Abstracts of Reviews of Effects (DARE), Health Technology Assessment Database (HTA), and Health Economics Evaluations Database (HEED) (2011, Issue 4) in The Cochrane Library. We used no language restrictions. Selection criteria We included randomised controlled trials of a fixed-dose combination therapy including at least one blood pressure lowering and one lipid lowering component versus usual care, placebo, or a single drug active component for any treatment duration in adults ≥ 18 years old with no restrictions on presence or absence of pre-existing cardiovascular disease. Data collection and analysis Three review authors independently selected studies for inclusion and extracted the data. We evaluated risk of bias using the Cochrane risk of bias assessment tool. We sought to include outcome data on all-cause mortality, fatal and non-fatal CVD events, adverse events, changes in systolic and diastolic blood pressure, total and low density lipoprotein (LDL) cholesterol concentrations, discontinuation rates, quality of life, and costs. We calculated risk ratios (RR) for dichotomous data and weighted mean differences (MD) for continuous data with 95% confidence intervals (CI) using fixed-effect models when heterogeneity was low (I2 < 50%) and random-effects models when heterogeneity was high (I2 > 50%). Main results We found nine randomised controlled trials with a total of 7047 participants. Seven of the nine trials evaluated the effects of fixed-dose combination therapy on primary CVD prevention, and the trial length ranged from six weeks to 15 months. We found a moderate to high risk of bias in the domains of selection, performance, detection, attrition, and other types of bias in five of the nine trials. Compared with the comparator groups, the effects of the fixed-dose combination treatment on mortality (1.2% versus 1.0%, RR 1.26, 95% CI 0.67 to 2.38, N = 3465) and cardiovascular events (4.0% versus 2.9%, RR 1.38, 95% CI 0.91 to 2.10, N = 2479) were uncertain (low quality evidence). The low event rates for these outcomes, limited availability of data as only two out of nine trials reported on these outcomes, and a high risk of bias in at least one domain suggest that these results should not be viewed with confidence. Adverse events were common in both the intervention (30%) and comparator (24%) groups, with participants randomised to fixed-dose combination therapy being 20% (95% CI 9% to 30%) more likely to report an adverse event. Notably, no serious adverse events were reported. Compared with placebo, the rate of discontinuation among participants randomised to fixed-dose combination was higher (14% versus 11%, RR 1.26 95% CI 1.02 to 1.55). The weighted mean differences in systolic and diastolic blood pressure between the intervention and control arms were -7.05 mmHg (95% CI -10.18 to -3.87) and -3.65 mmHg (95% CI -5.44 to -1.85), respectively. The weighted mean differences (95% CI) in total and LDL cholesterol between the intervention and control arms were -0.75 mmol/L (95% CI -1.05 to -0.46) and -0.81 mmol/L (95% CI -1.09 to -0.53), respectively. There was a high degree of statistical heterogeneity in comparisons of blood pressure and lipids (I2 ≥ 70% for all) that could not be explained, so these results should be viewed with caution. Fixed-dose combination therapy improved adherence to a multi-drug strategy by 33% (26% to 41%) compared with usual care, but this comparison was reported in only one study. The effects of fixed-dose combination therapy on quality of life are uncertain, though these results were reported in only one trial. No trials reported costs. Authors' conclusions Compared with placebo, single drug active component, or usual care, the effects of fixed-dose combination therapy on all-cause mortality or CVD events are uncertain; only few trials report these outcomes and the included trials were primarily designed to observe changes in CVD risk factor levels rather than clinical events. Reductions in blood pressure and lipid parameters are generally lower than those previously projected, though substantial heterogeneity of results exists. Fixed-dose combination therapy is associated with modest increases in adverse events compared with placebo, single drug active component, or usual care but may be associated with improved adherence to a multidrug regimen. Ongoing trials of fixed-dose combination therapy will likely inform key outcomes. PMID:24737108

  14. Cyclic, low-dose total body irradiation for metastatic neuroblastoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D'Angio, G.J.; Evans, A.E.

    1983-12-01

    Total body irradiation (TBI) can be thought of as a systemic anticancer agent. It therefore might best be given like an adjuvant drug, i.e., in tolerable doses, cyclically. The therapeutic ratio between normal bone marrow stem cells and suitably sensitive cancer cells should be widened by these means. Fourteen children with advanced (Stage IV) neuroblastomas were given 100-150 rad TBI in 50 rad daily fractions along with each three-week cycle of standard triple-agent chemotherapy (vincristine, DTIC, cyclophosphamide). Two patients died of toxicity and one is still undergoing therapy. Four of the remaining 12 survive free of disease for 12+ tomore » 31+ months. The regimen is well tolerated, but prolonged, pronounced bone marrow depression, especially thrombocytopenia, commonly occurs after doses of 300-450 rad.« less

  15. Switching From Age-Based Stimulus Dosing to Dose Titration Protocols in Electroconvulsive Therapy: Empirical Evidence for Better Patient Outcomes With Lower Peak and Cumulative Energy Doses.

    PubMed

    O'Neill-Kerr, Alex; Yassin, Anhar; Rogers, Stephen; Cornish, Janie

    2017-09-01

    The aim of this study was to test the proposition that adoption of a dose titration protocol may be associated with better patient outcomes, at lower treatment dose, and with comparable cumulative dose to that in patients treated using an age-based stimulus dosing protocol. This was an analysis of data assembled from archived records and based on cohorts of patients treated respectively on an age-based stimulus dosing protocol and on a dose titration protocol in the National Health Service in England. We demonstrated a significantly better response in the patient cohort treated with dose titration than with age-based stimulus dosing. Peak doses were less and the total cumulative dose was less in the dose titration group than in the age-based stimulus dosing group. Our findings are consistent with superior outcomes in patients treated using a dose titration protocol when compared with age-based stimulus dosing in a similar cohort of patients.

  16. Design of a boron neutron capture enhanced fast neutron therapy assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Zhonglu

    The use of boron neutron capture to boost tumor dose in fast neutron therapy has been investigated at several fast neutron therapy centers worldwide. This treatment is termed boron neutron capture enhanced fast neutron therapy (BNCEFNT). It is a combination of boron neutron capture therapy (BNCT) and fast neutron therapy (FNT). It is believed that BNCEFNT may be useful in the treatment of some radioresistant brain tumors, such as glioblastoma multiform (GBM). A boron neutron capture enhanced fast neutron therapy assembly has been designed for the Fermilab Neutron Therapy Facility (NTF). This assembly uses a tungsten filter and collimator nearmore » the patient's head, with a graphite reflector surrounding the head to significantly increase the dose due to boron neutron capture reactions. The assembly was designed using Monte Carlo radiation transport code MCNP version 5 for a standard 20x20 cm 2 treatment beam. The calculated boron dose enhancement at 5.7-cm depth in a water-filled head phantom in the assembly with a 5x5 cm 2 collimation was 21.9% per 100-ppm 10B for a 5.0-cm tungsten filter and 29.8% for a 8.5-cm tungsten filter. The corresponding dose rate for the 5.0-cm and 8.5-cm thick filters were 0.221 and 0.127 Gy/min, respectively; about 48.5% and 27.9% of the dose rate of the standard 10x10 cm 2 fast neutron treatment beam. To validate the design calculations, a simplified BNCEFNT assembly was built using four lead bricks to form a 5x5 cm 2 collimator. Five 1.0-cm thick 20x20 cm 2 tungsten plates were used to obtain different filter thicknesses and graphite bricks/blocks were used to form a reflector. Measurements of the dose enhancement of the simplified assembly in a water-filled head phantom were performed using a pair of tissue-equivalent ion chambers. One of the ion chambers is loaded with 1000-ppm natural boron (184-ppm 10B) to measure dose due to boron neutron capture. The measured dose enhancement at 5.0-cm depth in the head phantom for the 5.0-cm thick tungsten filter is (16.6 ± 1.8)%, which agrees well with the MCNP simulation of the simplified BNCEFNT assembly, (16.4 ± 0.5)%. The error in the calculated dose enhancement only considers the statistical uncertainties. The total dose rate measured at 5.0-cm depth using the non-borated ion chamber is (0.765 ± 0.076) Gy/MU, about 61% of the fast neutron standard dose rate (1.255Gy/MU) at 5.0-cm depth for the standard 10x10 cm 2 treatment beam. The increased doses to other organs due to the use of the BNCEFNT assembly were calculated using MCNP5 and a MIRD phantom. The activities of the activation products produced in the BNCEFNT assembly after neutron beam delivery were computed. The photon ambient dose rate due to the radioactive activation products was also estimated.« less

  17. Evaluating analytical ionization quenching correction models for 3D liquid organic scintillator detector

    NASA Astrophysics Data System (ADS)

    Alsanea, F.; Beddar, S.

    2017-05-01

    Proton therapy offers dosimetric advantage over conventional photon therapy due to the finite range of the proton beam, which improves dose conformity. However, one of the main challenges of proton beam therapy is verification of the complex treatment plans delivered to a patient. Thus, 3D measurements are needed to verify the complex dose distribution. A 3D organic scintillator detector is capable of such measurements. However, organic scintillators exhibit a non-linear relation to the ionization density called ionization quenching. The ionization quenching phenomenon in organic scintillators must be accounted for to obtain accurate dose measurements. We investigated the energy deposition by secondary electrons (EDSE) model to explain ionization quenching in 3D liquid organic scintillator when exposed to proton beams. The EDSE model was applied to volumetric scintillation measurement of proton pencil beam with energies of 85.6, 100.9, 144.9 and 161.9 MeV. The quenching parameter in EDSE model ρq was determined by plotting the total light output vs the initial energy of the ion. The results were compared to the Birks semi-empirical formula of scintillation light emission.

  18. Tumor Induction in Mice After Localized Single- or Fractionated-Dose Irradiation: Differences in Tumor Histotype and Genetic Susceptibility Based on Dose Scheduling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edmondson, Elijah F., E-mail: elijah.edmondson@colostate.edu; Hunter, Nancy R.; Weil, Michael M.

    2015-07-15

    Purpose: To investigate differences in tumor histotype, incidence, latency, and strain susceptibility in mice exposed to single-dose or clinically relevant, fractioned-dose γ-ray radiation. Methods and Materials: C3Hf/Kam and C57BL/6J mice were locally irradiated to the right hindlimb with either single large doses between 10 and 70 Gy or fractionated doses totaling 40 to 80 Gy delivered at 2-Gy/d fractions, 5 d/wk, for 4 to 8 weeks. The mice were closely evaluated for tumor development in the irradiated field for 800 days after irradiation, and all tumors were characterized histologically. Results: A total of 210 tumors were induced within the radiation field in 788 mice. Anmore » overall decrease in tumor incidence was observed after fractionated irradiation (16.4%) in comparison with single-dose irradiation (36.1%). Sarcomas were the predominant postirradiation tumor observed (n=201), with carcinomas occurring less frequently (n=9). The proportion of mice developing tumors increased significantly with total dose for both single-dose and fractionated schedules, and latencies were significantly decreased in mice exposed to larger total doses. C3Hf/Kam mice were more susceptible to tumor induction than C57BL/6J mice after single-dose irradiation; however, significant differences in tumor susceptibilities after fractionated radiation were not observed. For both strains of mice, osteosarcomas and hemangiosarcomas were significantly more common after fractionated irradiation, whereas fibrosarcomas and malignant fibrous histiocytomas were significantly more common after single-dose irradiation. Conclusions: This study investigated the tumorigenic effect of acute large doses in comparison with fractionated radiation in which both the dose and delivery schedule were similar to those used in clinical radiation therapy. Differences in tumor histotype after single-dose or fractionated radiation exposures provide novel in vivo evidence for differences in tumor susceptibility among stromal cell populations.« less

  19. Wearable glass beads for in vivo dosimetry of total skin electron irradiation treatments

    NASA Astrophysics Data System (ADS)

    Nabankema, S. K.; Jafari, S. M.; Peet, S. C.; Binny, D.; Sylvander, S. R.; Crowe, S. B.

    2017-11-01

    Glass beads have recently been proposed for use as radiation therapy dosimeters. Glass beads have a number of characteristics that make them suitable for in vivo skin dose measurements, including an ability to be worn on a string, and therefore avoid possible patient discomfort that may result from the use of adhesives. In this study, their use for in vivo dose measurements in total skin electron irradiation treatments has been tested. First, the dosimetric properties of cylindrical beads with a 3 mm diameter were characterised using electron fields produced by a linear accelerator. The mean individual bead reproducibility was demonstrated to be within 3%; and a batch variation of 7% was observed. The beads were shown to have a linear dose response, and both dose rate and beam energy independence, within the measurement uncertainty. Phantom measurements were then performed for a total skin electron irradiation beam arrangement, and results compared against optically stimulated luminescent dosimeters at five anatomical sites. For a majority of measurement locations, agreement within 3% was observed between the two dosimetry techniques, demonstrating the feasibility of glass beads as in vivo dosimeters for total skin electron irradiation; though further investigation may be needed to minimise uncertainty in results.

  20. Verification of Dose Distribution in Carbon Ion Radiation Therapy for Stage I Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Irie, Daisuke; Saitoh, Jun-ichi, E-mail: junsaito@gunma-u.ac.jp; Shirai, Katsuyuki

    Purpose: To evaluate robustness of dose distribution of carbon-ion radiation therapy (C-ion RT) in non-small cell lung cancer (NSCLC) and to identify factors affecting the dose distribution by simulated dose distribution. Methods and Materials: Eighty irradiation fields for delivery of C-ion RT were analyzed in 20 patients with stage I NSCLC. Computed tomography images were obtained twice before treatment initiation. Simulated dose distribution was reconstructed on computed tomography for confirmation under the same settings as actual treatment with respiratory gating and bony structure matching. Dose-volume histogram parameters, such as %D95 (percentage of D95 relative to the prescribed dose), were calculated.more » Patients with any field for which the %D95 of gross tumor volume (GTV) was below 90% were classified as unacceptable for treatment, and the optimal target margin for such cases was examined. Results: Five patients with a total of 8 fields (10% of total number of fields analyzed) were classified as unacceptable according to %D95 of GTV, although most patients showed no remarkable change in the dose-volume histogram parameters. Receiver operating characteristic curve analysis showed that tumor displacement and change in water-equivalent pathlength were significant predictive factors of unacceptable cases (P<.001 and P=.002, respectively). The main cause of degradation of the dose distribution was tumor displacement in 7 of the 8 unacceptable fields. A 6-mm planning target volume margin ensured a GTV %D95 of >90%, except in 1 extremely unacceptable field. Conclusions: According to this simulation analysis of C-ion RT for stage I NSCLC, a few fields were reported as unacceptable and required resetting of body position and reconfirmation. In addition, tumor displacement and change in water-equivalent pathlength (bone shift and/or chest wall thickness) were identified as factors influencing the robustness of dose distribution. Such uncertainties should be regarded in planning.« less

  1. Feasibility study on dosimetry verification of volumetric-modulated arc therapy-based total marrow irradiation.

    PubMed

    Liang, Yun; Kim, Gwe-Ya; Pawlicki, Todd; Mundt, Arno J; Mell, Loren K

    2013-03-04

    The purpose of this study was to develop dosimetry verification procedures for volumetric-modulated arc therapy (VMAT)-based total marrow irradiation (TMI). The VMAT based TMI plans were generated for three patients: one child and two adults. The planning target volume (PTV) was defined as bony skeleton, from head to mid-femur, with a 3 mm margin. The plan strategy similar to published studies was adopted. The PTV was divided into head and neck, chest, and pelvic regions, with separate plans each of which is composed of 2-3 arcs/fields. Multiple isocenters were evenly distributed along the patient's axial direction. The focus of this study is to establish a dosimetry quality assurance procedure involving both two-dimensional (2D) and three-dimensional (3D) volumetric verifications, which is desirable for a large PTV treated with multiple isocenters. The 2D dose verification was performed with film for gamma evaluation and absolute point dose was measured with ion chamber, with attention to the junction between neighboring plans regarding hot/cold spots. The 3D volumetric dose verification used commercial dose reconstruction software to reconstruct dose from electronic portal imaging devices (EPID) images. The gamma evaluation criteria in both 2D and 3D verification were 5% absolute point dose difference and 3 mm of distance to agreement. With film dosimetry, the overall average gamma passing rate was 98.2% and absolute dose difference was 3.9% in junction areas among the test patients; with volumetric portal dosimetry, the corresponding numbers were 90.7% and 2.4%. A dosimetry verification procedure involving both 2D and 3D was developed for VMAT-based TMI. The initial results are encouraging and warrant further investigation in clinical trials.

  2. Efficacy of levamisole in children with frequently relapsing and steroid-dependent nephrotic syndrome.

    PubMed

    Ekambaram, Sudha; Mahalingam, Vijayakumar; Nageswaran, Prahlad; Udani, Amish; Geminiganesan, Sangeetha; Priyadarshini, Shweta

    2014-05-01

    To assess the efficacy of levamisole in frequently relapsing nephrotic syndrome and steroid-dependent nephrotic syndrome. Retrospective analysis of hospital case records. Pediatric nephrology department of a tertiary referral pediatric hospital. 62 children with frequently relapsing nephrotic syndrome and 35 children with steroid-dependent nephrotic syndrome. Case records of children who were diagnosed as steroid-dependant or frequently-relapsing nephrotic syndrome from June 2004 to June 2011, were reviewed. Levamisole was given daily (2 mg/kg/d) along with tapering doses of alternate day steroids after remission on daily steroids. Levamisole was effective in 77.3% children with a better (80.6%) efficacy in frequently relapsing nephrotic syndrome. A total of 34 children completed 1 year follow-up post levamisole therapy. The cumulative mean (SD) steroid dose 1-year before therapy was 4109(1154) mg/m2 and 1-year post therapy was 661 (11) mg/m2 (P<0.001). The relapses were also less during the period of post-levamisole therapy. Levamisole is an effective alternative therapy in frequently relapsing and steroid-dependent nephrotic syndrome.

  3. Subcutaneous Injection of Testosterone Is an Effective and Preferred Alternative to Intramuscular Injection: Demonstration in Female-to-Male Transgender Patients.

    PubMed

    Spratt, Daniel I; Stewart, India I; Savage, Clara; Craig, Wendy; Spack, Norman P; Chandler, Donald Walt; Spratt, Lindsey V; Eimicke, Toni; Olshan, Jerrold S

    2017-07-01

    Testosterone (T) is commonly administered intramuscularly to treat hypogonadal males and female-to-male (FTM) transgender patients. However, these injections can involve significant discomfort and may require arrangements for administration by others. We assessed whether T could be administered effectively and safely subcutaneously as an alternative to intramuscular (IM) injections. Retrospective cohort study. Outpatient reproductive endocrinology clinic at an academic medical center. Sixty-three FTM transgender patients aged >18 years electing to receive subcutaneous (SC) T therapy for sex transition were included. Fifty-three patients were premenopausal. Patients were administered T cypionate or enanthate weekly at an initial dose of 50 mg. Dose was adjusted if needed to achieve serum total T levels within the normal male range. Serum concentrations of free and total T and total estradiol (E2), masculinization, and surveillance for reactions at injection sites. Serum T levels within the normal male range were achieved in all 63 patients with doses of 50 to 150 mg (median, 75/80 mg). Therapy was effective across a wide range of body mass index (19.0 to 49.9 kg/m2). Minor and transient local reactions were reported in 9 out of 63 patients. Among 53 premenopausal patients, 51 achieved amenorrhea and 35 achieved serum E2 concentrations <50 pg/mL. Twenty-two patients were originally receiving IM and switched to SC therapy. All 22 had a mild (n = 2) or marked (n = 20) preference for SC injections; none preferred IM injections. Our observations indicate that SC T injections are an effective, safe, and well-accepted alternative to IM T injections. Copyright © 2017 Endocrine Society

  4. [Results of radioiodine therapy in different forms of hyperthyroidism in relation to the planned dosage].

    PubMed

    Moser, E

    1992-07-01

    The aim of this study was to assess the efficacy of radioiodine therapy (131J) in a large group (n = 925) of hyperthyroid patients treated at two major departments of nuclear medicine (Freiburg, abbr. FR, and Munich, abbr. M). 761 patients suffered from non-immunogenic hyperthyroidism (Plummer's disease) and the remaining 164 patients from immunogenic hyperthyroidism (Graves' disease). In these cases, radioiodine therapy using doses between 60 and 80 Gy proved ineffective, FR (80 Gy) recording 28% success and M (60 Gy) 54%. A dose of 150 Gy, however, is successful in more than 80% of the cases: FR 81%, M86%. However, the incidence rate of hypothyroidism increases consecutively with 150 Gy: FR 49%, M 62%. In patients suffering from Plummer's disease, the solitary autonomous nodule can be eliminated by radioiodine therapy (400 Gy) with a high rate of success (95%); the same applies to multinodular autonomous adenomas. The therapeutic concept applying a dose of 400 Gy to the total functional autonomous tissue (delineated by ultrasound) yields slightly better results (95%) than 150 Gy applied to thyroid gland (M88%, FR82%). This dosimetric compromise is a practicable alternative which is tolerably successful. In patients suffering from disseminated non-immunogenic hyperthyroidism, a dose of 150 Gy applied to the entire organ succeeds in 85% of the cases. The rate of hypothyroidism resulting from these dose recommendations is the lesser evil compared to residual or recurrent hyperthyroidism, since hypothyroid patients can be treated without any problem with thyroid hormones.

  5. TH-CD-209-10: Scanning Proton Arc Therapy (SPArc) - The First Robust and Delivery-Efficient Spot Scanning Proton Arc Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, X; Li, X; Zhang, J

    Purpose: To develop a delivery-efficient proton spot-scanning arc therapy technique with robust plan quality. Methods: We developed a Scanning Proton Arc(SPArc) optimization algorithm integrated with (1)Control point re-sampling by splitting control point into adjacent sub-control points; (2)Energy layer re-distribution by assigning the original energy layers to the new sub-control points; (3)Energy layer filtration by deleting low MU weighting energy layers; (4)Energy layer re-sampling by sampling additional layers to ensure the optimal solution. A bilateral head and neck oropharynx case and a non-mobile lung target case were tested. Plan quality and total estimated delivery time were compared to original robust optimizedmore » multi-field step-and-shoot arc plan without SPArc optimization (Arcmulti-field) and standard robust optimized Intensity Modulated Proton Therapy(IMPT) plans. Dose-Volume-Histograms (DVH) of target and Organ-at-Risks (OARs) were analyzed along with all worst case scenarios. Total delivery time was calculated based on the assumption of a 360 degree gantry room with 1 RPM rotation speed, 2ms spot switching time, beam current 1nA, minimum spot weighting 0.01 MU, energy-layer-switching-time (ELST) from 0.5 to 4s. Results: Compared to IMPT, SPArc delivered less integral dose(−14% lung and −8% oropharynx). For lung case, SPArc reduced 60% of skin max dose, 35% of rib max dose and 15% of lung mean dose. Conformity Index is improved from 7.6(IMPT) to 4.0(SPArc). Compared to Arcmulti-field, SPArc reduced number of energy layers by 61%(276 layers in lung) and 80%(1008 layers in oropharynx) while kept the same robust plan quality. With ELST from 0.5s to 4s, it reduced 55%–60% of Arcmulti-field delivery time for the lung case and 56%–67% for the oropharynx case. Conclusion: SPArc is the first robust and delivery-efficient proton spot-scanning arc therapy technique which could be implemented in routine clinic. For modern proton machine with ELST close to 0.5s, SPArc would be a popular treatment option for both single and multi-room center.« less

  6. Comparison of doses received by the hippocampus in patients treated with single isocenter– vs multiple isocenter–based stereotactic radiation therapy to the brain for multiple brain metastases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Algan, Ozer, E-mail: oalgan@ouhsc.edu; Giem, Jared; Young, Julie

    To investigate the doses received by the hippocampus and normal brain tissue during a course of stereotactic radiation therapy using a single isocenter (SI)–based or multiple isocenter (MI)–based treatment planning in patients with less than 4 brain metastases. In total, 10 patients with magnetic resonance imaging (MRI) demonstrating 2-3 brain metastases were included in this retrospective study, and 2 sets of stereotactic intensity-modulated radiation therapy (IMRT) treatment plans (SI vs MI) were generated. The hippocampus was contoured on SPGR sequences, and doses received by the hippocampus and the brain were calculated and compared between the 2 treatment techniques. A totalmore » of 23 lesions in 10 patients were evaluated. The median tumor volume, the right hippocampus volume, and the left hippocampus volume were 3.15, 3.24, and 2.63 mL, respectively. In comparing the 2 treatment plans, there was no difference in the planning target volume (PTV) coverage except in the tail for the dose-volume histogram (DVH) curve. The only statistically significant dosimetric parameter was the V{sub 100}. All of the other measured dosimetric parameters including the V{sub 95}, V{sub 99}, and D{sub 100} were not significantly different between the 2 treatment planning techniques. None of the dosimetric parameters evaluated for the hippocampus revealed any statistically significant difference between the MI and SI plans. The total brain doses were slightly higher in the SI plans, especially in the lower dose region, although this difference was not statistically different. The use of SI-based treatment plan resulted in a 35% reduction in beam-on time. The use of SI treatments for patients with up to 3 brain metastases produces similar PTV coverage and similar normal tissue doses to the hippocampus and the brain when compared with MI plans. SI treatment planning should be considered in patients with multiple brain metastases undergoing stereotactic treatment.« less

  7. Brainstem dose is associated with patient-reported acute fatigue in head and neck cancer radiation therapy.

    PubMed

    Ferris, Matthew J; Zhong, Jim; Switchenko, Jeffrey M; Higgins, Kristin A; Cassidy, Richard J; McDonald, Mark W; Eaton, Bree R; Patel, Kirtesh R; Steuer, Conor E; Baddour, H Michael; Miller, Andrew H; Bruner, Deborah W; Xiao, Canhua; Beitler, Jonathan J

    2018-01-01

    Radiation (RT) dose to the central nervous system (CNS) has been implicated as a contributor to treatment-related fatigue in head and neck cancer (HNC) patients undergoing radiation therapy (RT). This study evaluates the association of RT dose to CNS structures with patient-reported (PRO) fatigue scores in a population of HNC patients. At pre-RT (baseline), 6th week of RT, and 1-month post-RT time points, Multidimensional Fatigue Inventory (MFI-20) scores were prospectively obtained from 124 patients undergoing definitive treatment for HNC. Medulla, pons, midbrain, total brainstem, cerebellum, posterior fossa, and pituitary dosimetry were evaluated using summary statistics and dose-volume histograms, and associations with MFI-20 scores were analyzed. Maximum dose (Dmax) to the brainstem and medulla was significantly associated with MFI-20 scores at 6th week of RT and 1-month post-RT time points, after controlling for baseline scores (p<0.05). Each 1Gy increase in medulla Dmax resulted in an increase in total MFI-20 score over baseline of 0.30 (p=0.026), and 0.25 (p=0.037), at the 6th week of RT and 1-month post-RT, respectively. Each 1Gy increase in brainstem Dmax resulted in an increase in total MFI-20 score over baseline of 0.30 (p=0.027), and 0.25 (p=0.037) at the 6th week of RT, 1-month post-RT, respectively. Statistically significant associations were not found between dosimetry for the other CNS structures and MFI-20 scores. In this analysis of PRO fatigue scores from a population of patients undergoing definitive RT for HNC, maximum dose to the brainstem and medulla was associated with a significantly increased risk of acute patient fatigue. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Cherenkov imaging for Total Skin Electron Therapy (TSET)

    NASA Astrophysics Data System (ADS)

    Xie, Yunhe; Petroccia, Heather; Maity, Amit; Miao, Tianshun; Zhu, Yihua; Bruza, Petr; Pogue, Brian W.; Andreozzi, Jacqueline M.; Plastaras, John P.; Dong, Lei; Zhu, Timothy C.

    2018-03-01

    Total Skin Electron Therapy (TSET) utilizes high-energy electrons to treat cancers on the entire body surface. The otherwise invisible radiation beam can be observed via the optical Cherenkov photons emitted from interaction between the high-energy electron beam and tissue. Using a specialized camera-system, the Cherenkov emission can thus be used to evaluate the dose uniformity on the surface of the patient in real-time. Each patient was also monitored during TSET via in-vivo detectors (IVD) in nine locations. Patients undergoing TSET in various conditions (whole body and half body) were imaged and analyzed, and the viability of the system to provide clinical feedback was established.

  9. Intraoperative Magnesium Administration Does Not Reduce Postoperative Atrial Fibrillation After Cardiac Surgery

    PubMed Central

    Klinger, Rebecca Y.; Thunberg, Christopher A.; White, William D.; Fontes, Manuel; Waldron, Nathan H.; Piccini, Jonathan P.; Hughes, G. Chad; Podgoreanu, Mihai V.; Stafford-Smith, Mark; Newman, Mark F.; Mathew, Joseph P.

    2015-01-01

    Background Hypomagnesemia has been associated with an increased risk of postoperative atrial fibrillation (POAF). While earlier studies have suggested a beneficial effect of magnesium (Mg) therapy, almost all of these are limited by small sample size and relatively low Mg dose. We hypothesized that high-dose Mg decreases the occurrence of new-onset POAF, and we tested this hypothesis using data from a prospective trial assessing the effect of Mg on cognitive outcomes in cardiac surgical patients. Methods A total of 389 patients undergoing cardiac surgery were enrolled in this double-blind, placebo-controlled trial. Subjects were randomized to receive Mg as a 50 mg/kg bolus immediately after induction of anesthesia followed by another 50 mg/kg as an infusion given over 3 h (total dose 100 mg/kg) or placebo. The effect of Mg therapy on POAF was tested with logistic regression, adjusting for the risk of AF using the Risk Index for Atrial Fibrillation after Cardiac Surgery. Results Among the 363 patients analyzed, after excluding patients with chronic or acute preoperative AF (Placebo: n=177, Mg: n=186), the incidence of new-onset POAF was 42.5% (95% CI: 35 – 50%) in the Mg group compared to 37.9% (95% CI: 31 – 45%) in the placebo group (p=0.40). The 95% confidence interval for this absolute risk difference of 4.6% is −5.5% to 14.7%. The time to onset of POAF was also identical between the groups, and no significant effect of Mg was found in logistic regression analysis adjusting for AF risk (odds ratio 1.09 with 95% CI 0.69 – 1.72, p=0.73). Conclusions High-dose intraoperative Mg therapy did not decrease the incidence of new-onset POAF after cardiac surgery. PMID:26237622

  10. Role of Surgical Versus Clinical Staging in Chemoradiated FIGO Stage IIB-IVA Cervical Cancer Patients-Acute Toxicity and Treatment Quality of the Uterus-11 Multicenter Phase III Intergroup Trial of the German Radiation Oncology Group and the Gynecologic Cancer Group.

    PubMed

    Marnitz, Simone; Martus, Peter; Köhler, Christhardt; Stromberger, Carmen; Asse, Elke; Mallmann, Peter; Schmidberger, Heinz; Affonso Júnior, Renato José; Nunes, João Soares; Sehouli, Jalid; Budach, Volker

    2016-02-01

    The Uterus-11 trial was designed to evaluate the role of surgical staging in patients with cervical cancer before primary chemoradiation therapy (CRT). The present report provides the toxicity data stratified by the treatment arm and technique. A total of 255 patients with carcinoma of the uterine cervix (International Federation of Gynecology and Obstetrics stage IIB-IVA) were randomized to either surgical staging followed by CRT (arm A) or clinical staging followed by CRT (arm B). Patients with para-aortic metastases underwent extended field radiation therapy (RT). Brachytherapy was mandatory. The present report presents the acute therapy-related toxicities stratified by treatment arm and radiation technique. A total of 240 patients were eligible (n=121 in arm A; n=119 in arm B). Of the 240 patients, 236 (98.3%) underwent external beam RT with a median total dose of 50.4 Gy. The mean treatment duration was 53 days. Of the patients, 60% underwent intensity modulated RT (IMRT). A total of 234 patients (97.5%) underwent chemotherapy, and 231 (96.3%) underwent brachytherapy, with a median single dose of 6 Gy covering the tumor to a median nominal total dose of 28 Gy. Treatment was well tolerated, with 0% grade ≥3 genitourinary and gastrointestinal toxicity, 6% grade 3 nausea, 3% grade 3 vomiting, and <2% grade 3 diarrhea. More patients after surgical staging experienced grade 2 anemia (54.3% in arm A vs 45.3% in arm B; P=.074) and grade 2 leukocytopenia (41.4% vs 31.6%; P=.56). Of the patients who received IMRT versus a 3-dimensional technique, 65.3% versus 33.7% presented with grade 2 anemia. Grade 3 gastrointestinal and grade 2 bladder toxicity were significantly reduced with the use of IMRT. The incidence and severity of acute therapy-related toxicity compared favorably with those from other randomized trials. Excellent adherence to treatment and treatment quality was achieved compared with patterns of care analyses. Surgical staging led to a doubled number of patients treated with extended field RT. The question of whether surgical staging is beneficial in the context of primary CRT requires further study. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. SLCO1B1 Polymorphisms are Associated With Drug Intolerance in Childhood Leukemia Maintenance Therapy.

    PubMed

    Eldem, İrem; Yavuz, Duygu; Cumaoğullari, Özge; İleri, Talia; Ünal İnce, Elif; Ertem, Mehmet; Doğanay Erdoğan, Beyza; Bindak, Recep; Özdağ, Hilal; Şatiroğlu-Tufan, N Lale; Uysal, L Zümrüt

    2018-04-20

    Therapy discontinuations and toxicities occur because of significant interindividual variations in 6-mercaptopurine (6-MP) and methotrexate (MTX) response during maintenance therapy of childhood acute lymphoblastic leukemia (ALL). 6-MP/MTX intolerance in some of the patients cannot be explained by thiopurine S-methyl transferase (TPMT) gene variants. In this study, we aimed to investigate candidate pharmacogenetic determinants of 6-MP and MTX intolerance in Turkish ALL children. In total, 48 children with ALL who had completed or were receiving maintenance therapy according to Children's Oncology Group (COG) protocols were enrolled. Fifteen single-nucleotide polymorphisms in 8 candidate genes that were related to drug toxicity or had a role in the 6-MP/MTX metabolism (TPMT, ITPA, MTHFR, IMPDH2, PACSIN2, SLCO1B1, ABCC4, and PYGL) were genotyped by competitive allele-specific PCR (KASP). Drug doses during maintenance therapy were modified according to the protocol. The median drug dose intensity was 50% (28% to 92%) for 6-MP and 58% (27% to 99%) for MTX in the first year of maintenance therapy, which were lower than that scheduled in all patients. Among the analyzed polymorphisms, variant alleles in SLCO1B1 rs4149056 and rs11045879 were found to be associated with lower 6-MP/MTX tolerance. SLCO1B1 rs4149056 and rs11045879 polymorphisms may be important genetic markers to individualize 6-MP/MTX doses.

  12. Revisiting Dosing Regimen Using Pharmacokinetic/Pharmacodynamic Mathematical Modeling: Densification and Intensification of Combination Cancer Therapy.

    PubMed

    Meille, Christophe; Barbolosi, Dominique; Ciccolini, Joseph; Freyer, Gilles; Iliadis, Athanassios

    2016-08-01

    Controlling effects of drugs administered in combination is particularly challenging with a densified regimen because of life-threatening hematological toxicities. We have developed a mathematical model to optimize drug dosing regimens and to redesign the dose intensification-dose escalation process, using densified cycles of combined anticancer drugs. A generic mathematical model was developed to describe the main components of the real process, including pharmacokinetics, safety and efficacy pharmacodynamics, and non-hematological toxicity risk. This model allowed for computing the distribution of the total drug amount of each drug in combination, for each escalation dose level, in order to minimize the average tumor mass for each cycle. This was achieved while complying with absolute neutrophil count clinical constraints and without exceeding a fixed risk of non-hematological dose-limiting toxicity. The innovative part of this work was the development of densifying and intensifying designs in a unified procedure. This model enabled us to determine the appropriate regimen in a pilot phase I/II study in metastatic breast patients for a 2-week-cycle treatment of docetaxel plus epirubicin doublet, and to propose a new dose-ranging process. In addition to the present application, this method can be further used to achieve optimization of any combination therapy, thus improving the efficacy versus toxicity balance of such a regimen.

  13. Effects of high-dose parenteral vitamin D therapy on lipid profile and blood pressure in patients with diabetic nephropathy: A randomized double-blind clinical trial.

    PubMed

    Liyanage, Gayani C; Lekamwasam, Sarath; Weerarathna, Thilak P; Liyanage, Chandrani E

    2017-12-01

    Aim of this study was to determine the effect of high dose vitamin D given to patients with early diabetic renal disease on systolic and diastolic blood pressure, total cholesterol (TC), low-density lipoproteins (LDL), triglycerides (TG) and high density lipoproteins (HDL) in a randomized controlled trial MATERIALS AND METHOD: Patients with early diabetic nephropathy were recruited. Selected patients were allocated to two groups by Block randomization method. Treatment group received 50,000 IU of vitamin D3 intramuscularly and the control group was given an equal volume of distilled water (0.25mL) monthly for six months. Blood and urine were collected at the baseline for biochemical analyses and blood pressure was measured. After six months all the measurements done at the baseline were repeated. Of 155 patients invited, 85 were randomly assigned to two groups. No significant differences were found between treatment and control groups at the baseline. Vitamin D therapy significantly reduced DBP, total cholesterol and LDL but the between group differences were not significant. There was an increase in HDL cholesterol level in the treatment group while there was no change in the control group Between groups difference was significant (P=<0.001). There was a significant improvement of serum HDL level with six months therapy of high dose vitamin D in patients with early diabetic nephropathy. Copyright © 2017 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  14. Efficacy and Safety of Adjuvant Proton Therapy Combined With Surgery for Chondrosarcoma of the Skull Base: A Retrospective, Population-Based Study.

    PubMed

    Feuvret, Loïc; Bracci, Stefano; Calugaru, Valentin; Bolle, Stéphanie; Mammar, Hamid; De Marzi, Ludovic; Bresson, Damien; Habrand, Jean-Louis; Mazeron, Jean-Jacques; Dendale, Rémi; Noël, Georges

    2016-05-01

    Chondrosarcoma is a rare malignant tumor of the cartilage affecting young adults. Surgery, followed by charged-particle irradiation, is considered the reference standard for the treatment of patients with grade I to II skull base chondrosarcoma. The present study was conducted to assess the effect of the quality of surgery and radiation therapy parameters on local control (LC) and overall survival (OS). From 1996 to 2013, 159 patients (median age 40 years, range 12-83) were treated with either protons alone or a combination of protons and photons. The median total dose delivered was 70.2 Gy (relative biologic effectiveness [RBE]; range 67-71). Debulking and biopsy were performed in 133 and 13 patients, respectively. With a median follow-up of 77 months (range 2-214), 5 tumors relapsed based on the initial gross tumor volume. The 5- and 10-year LC rates were 96.4% and 93.5%, respectively, and the 5- and 10-year OS rates were 94.9% and 87%, respectively. A total of 16 patients died (13 of intercurrent disease, 3 of disease progression). On multivariate analysis, age <40 years and primary disease status were independent favorable prognostic factors for progression-free survival and OS, and local tumor control was an independent favorable predictor of OS. In contrast, the extent of surgery, dosimetric parameters, and adjacent organs at risk were not prognostic factors for LC or OS. Systematic high-dose postoperative proton therapy for skull base chondrosarcoma can achieve a high LC rate with a low toxicity profile. Maximal safe surgery, followed by high-dose conformal proton therapy, is therefore recommended. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Efficacy and Safety of Adjuvant Proton Therapy Combined With Surgery for Chondrosarcoma of the Skull Base: A Retrospective, Population-Based Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feuvret, Loïc, E-mail: loic.feuvret@psl.aphp.fr; Department of Radiation Oncology, Institut Curie–Centre de protonthérapie d'Orsay; Bracci, Stefano

    Purpose: Chondrosarcoma is a rare malignant tumor of the cartilage affecting young adults. Surgery, followed by charged-particle irradiation, is considered the reference standard for the treatment of patients with grade I to II skull base chondrosarcoma. The present study was conducted to assess the effect of the quality of surgery and radiation therapy parameters on local control (LC) and overall survival (OS). Methods and Materials: From 1996 to 2013, 159 patients (median age 40 years, range 12-83) were treated with either protons alone or a combination of protons and photons. The median total dose delivered was 70.2 Gy (relative biologic effectiveness [RBE];more » range 67-71). Debulking and biopsy were performed in 133 and 13 patients, respectively. Results: With a median follow-up of 77 months (range 2-214), 5 tumors relapsed based on the initial gross tumor volume. The 5- and 10-year LC rates were 96.4% and 93.5%, respectively, and the 5- and 10-year OS rates were 94.9% and 87%, respectively. A total of 16 patients died (13 of intercurrent disease, 3 of disease progression). On multivariate analysis, age <40 years and primary disease status were independent favorable prognostic factors for progression-free survival and OS, and local tumor control was an independent favorable predictor of OS. In contrast, the extent of surgery, dosimetric parameters, and adjacent organs at risk were not prognostic factors for LC or OS. Conclusions: Systematic high-dose postoperative proton therapy for skull base chondrosarcoma can achieve a high LC rate with a low toxicity profile. Maximal safe surgery, followed by high-dose conformal proton therapy, is therefore recommended.« less

  16. Dosimetric evaluation of total marrow irradiation using 2 different planning systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nalichowski, Adrian, E-mail: nalichoa@karmanos.org; Eagle, Don G.; Burmeister, Jay

    This study compared 2 different treatment planning systems (TPSs) for quality and efficiency of total marrow irradiation (TMI) plans. The TPSs used in this study were VOxel-Less Optimization (VoLO) (Accuray Inc, Sunnyvale, CA) using helical dose delivery on a Tomotherapy Hi-Art treatment unit and Eclipse (Varian Medical Systems Inc, Palo Alto, CA) using volumetric modulated arc therapy (VMAT) dose delivery on a Varian iX treatment unit. A total dose of 1200 cGy was prescribed to cover 95% of the planning target volume (PTV). The plans were optimized and calculated based on a single CT data and structure set using themore » Alderson Rando phantom (The Phantom Laboratory, Salem, NY) and physician contoured target and organ at risk (OAR) volumes. The OARs were lungs, heart, liver, kidneys, brain, and small bowel. The plans were evaluated based on plan quality, time to optimize the plan and calculate the dose, and beam on time. The resulting mean and maximum doses to the PTV were 1268 and 1465 cGy for VoLO and 1284 and 1541 cGy for Eclipse, respectively. For 5 of 6 OAR structures the VoLO system achieved lower mean and D10 doses ranging from 22% to 52% and 3% to 44%, respectively. Total computational time including only optimization and dose calculation were 0.9 hours for VoLO and 3.8 hours for Eclipse. These times do not include user-dependent target delineation and field setup. Both planning systems are capable of creating high-quality plans for total marrow irradiation. The VoLO planning system was able to achieve more uniform dose distribution throughout the target volume and steeper dose fall off, resulting in superior OAR sparing. VoLO's graphics processing unit (GPU)–based optimization and dose calculation algorithm also allowed much faster creation of TMI plans.« less

  17. Comparison of alternative βhCG follow-up protocols after single-dose methotrexate therapy for tubal ectopic pregnancy.

    PubMed

    Şükür, Yavuz Emre; Koyuncu, Kazibe; Seval, Mehmet Murat; Çetinkaya, Esra; Dökmeci, Fulya

    2017-12-01

    To evaluate the performances of five different βhCG follow-up protocols after single-dose methotrexate therapy for tubal ectopic pregnancy (EP). Data of patients who received single-dose methotrexate therapy for tubal EP at a university hospital between January 2011 and July 2016 were reviewed. A 'successful methotrexate treatment' was defined if the EP treated with no need for surgery. The performances of different protocols were tested by comparing with the currently used '15% βhCG decrease between days 4 and 7' protocol. The tested follow-up protocols were '20, 25%, and any βhCG decrease between days 0/1 and 7' and '20% and any βhCG decrease between days 0/1 and 4'. Among the 96 patients evaluated, 12 (12.5%) required second dose. Totally, 91 (94.8%) patients treated successfully with no need for surgery. Four patients were operated within 4 days following the second dose. One patient who did not need second dose according to the standard follow-up protocol was operated on the 10th day due to rupture (specificity = 80%). Two protocols, namely '20% βhCG decrease between days 0/1 and 7' and 'any βhCG decrease between days 0/1 and 7' did not show statistically significant differences from the index protocol regarding the number of patients who should be assigned to 2nd dose. 'Any βhCG decrease between days 0/1 and 7' protocol may substitute the currently used one to decide second dose methotrexate in tubal EP management. Omitting 4th day measurement seems to be more convenient and cost effective.

  18. Risks of secondary malignancies with heterotopic bone radiation therapy for patients younger than 40 years

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cadieux, Catherine L., E-mail: ccadieux@umail.iu.edu; DesRosiers, Colleen; McMullen, Kevin

    Heterotopic ossification (HO) of the bone is defined as a benign condition in which abnormal bone formation occurs in soft tissue. One of the most common prophylactic treatments for HO is radiation therapy (RT). This study retrospectively reviewed 20 patients younger than the age of 40 who received radiation to prevent HO in a single fraction of 7 Gray. The purpose of this study is to assess the risk of a second malignancy in these patients by recreating their treatment fields and contouring organs at risk to estimate the radiation dose absorbed by normal tissues outside the radiation treatment field.more » Diagnostic computed tomography (CT) scans for each patient were used to recreate treatment fields and to calculate dose to structures of interest. The distance from the field edge to each structure and its depth was recorded. Dose measurements in a water phantom were performed for the range of depths, distances, and field sizes used in the actual treatment plans. Computer-generated doses were compared to estimates based on measurement. The structure dose recorded was the higher dose generated between the 2 methods. Scatter dose was recorded to the rectum, bladder, sigmoid colon, small bowel, ovaries and utero-cervix in female patients, and prostate and gonads in male patients. In some patients, there is considerable dose received by certain organs from scatter because of their proximity to the radiation field. The average dose to the ovarian region was 4.125 Gy with a range of 1.085 to 6.228 Gy. The risk estimate for these patients ranged from 0.16% to 0.93%. The average total lifetime risk estimate for the bladder in all patients is 0.22% and the average total lifetime risk estimate for the remainder organs in all patients is 1.25%. In conclusions, proper shielding created from multileaf collimators (MLCs), blocks, and shields should always be used when possible.« less

  19. Total marrow irradiation using Helical TomoTherapy

    NASA Astrophysics Data System (ADS)

    Garcia-Fernandez, Lourdes Maria

    Clinical dose response data of human tumours are limited or restricted to a radiation dose range determined by the level of toxicity to the normal tissues. This is the case for the most common disseminated plasma cell neoplasm, multiple myeloma, where the maximum dose deliverable to the entire bony skeleton using a standard total body irradiation (TBI) technique is limited to about 12 Gy. This study is part of scientific background of a phase I/II dose escalation clinical trial for multiple myeloma using image-guided intensity modulated radiotherapy (IG-IMRT) to deliver high dose to the entire volume of bone marrow with Helical TomoTherapy (HT). This relatively new technology can deliver highly conformal dose distributions to complex target shapes while reducing the dose to critical normal tissues. In this study tools for comparing and predicting the effectiveness of different approaches to total marrow irradiation (TMI) using HT were provided. The expected dose response for plasma cell neoplasms was computed and a radiobiological evaluation of different treatment cohorts in a dose escalating study was performed. Normal tissue complication probability (NTCP) and tumour control probability (TCP) models were applied to an actual TMI treatment plan for a patient and the implications of using different longitudinal field widths were assessed. The optimum dose was ˜39 Gy for which a predicted tumour control of 95% (+/-3%) was obtained, with a predicted 3% (0, 8%) occurrence of radiation pneumonitis. Tissue sparing was seen by using smaller field widths only in the organs of the head. This suggests it would be beneficial to use the small fields in the head only since using small fields for the whole treatment would lead to long treatment times. In TMI it may be necessary to junction two longitudinally adjacent treatment volumes to form a contiguous planning target volume PTV. For instance, this is the case when a different SUP-INF spatial resolution is required or when the PTV length exceeds the bed travel distance. In this work, the dosimetric challenges associated with junctioning longitudinally adjacent PTVs with HT were analyzed and the feasibility of PTV junctioning was demonstrated. The benefits of spatially dividing or splitting the treatment into a few sub-treatments along the longitudinal direction were also investigated.

  20. A randomized, double-blind, placebo-controlled, dose-ranging study of lisdexamfetamine dimesylate augmentation for major depressive disorder in adults with inadequate response to antidepressant therapy

    PubMed Central

    Richards, Cynthia; Iosifescu, Dan V; Mago, Rajnish; Sarkis, Elias; Reynolds, James; Geibel, Brooke; Dauphin, Matthew

    2017-01-01

    Background: This randomized, double-blind, placebo-controlled study evaluated dose-response relationships of lisdexamfetamine dimesylate when used as augmentation for major depressive disorder in individuals exhibiting inadequate responses to antidepressant monotherapy. Methods: Eligible adults (18–65 years) were assigned to antidepressant monotherapy (escitalopram or venlafaxine extended-release) plus lisdexamfetamine dimesylate-matching placebo during an eight-week single-blind lead-in phase. Participants meeting randomization criteria were randomized (1:1:1:1:1) to eight weeks of lisdexamfetamine dimesylate (10, 30, 50, or 70 mg) or placebo while maintaining antidepressant therapy. Dose-responses for changes from augmentation baseline to week 16/early termination for Montgomery-Åsberg Depression Rating Scale total score (primary efficacy endpoint) and vital signs (systolic and diastolic blood pressure and pulse) were assessed using multiple comparisons procedures with modeling. Results: For Montgomery-Åsberg Depression Rating Scale total score change, no significant dose-responses were observed for any candidate dose-response curve (all p>0.10). In the dose-response evaluable population, least squares mean (90% confidence interval) treatment differences versus placebo for Montgomery-Åsberg Depression Rating Scale total score change at week 16 were −1.4 (−3.9, 1.2), 0.1 (−2.5, 2.7), −0.7 (−3.4, 2.0), and −0.9 (−3.5, 1.6) with 10, 30, 50, and 70 mg lisdexamfetamine dimesylate, respectively. For all vital sign parameters, lisdexamfetamine dimesylate exhibited significant dose-responses for all candidate dose-response curves (all p<0.10), with increases observed as lisdexamfetamine dimesylate dose increased; a linear relationship provided the best fit. Mean±standard deviation changes from augmentation baseline for systolic and diastolic blood pressure and pulse at week 16/early termination were −0.7±9.90 and −0.3±7.24 mm Hg and 0.2±10.57 bpm with placebo and were 1.9±9.47 and 0.8±7.40 mm Hg and 3.6±9.74 bpm with lisdexamfetamine dimesylate (all doses combined). The safety and tolerability profile of lisdexamfetamine dimesylate was consistent with previous studies. Conclusions: Lisdexamfetamine dimesylate augmentation did not provide benefit over placebo in adults with inadequate responses to antidepressant monotherapy based on the assessed efficacy measures. PMID:28857719

  1. General Anaesthesia Protocols for Patients Undergoing Electroconvulsive Therapy

    PubMed Central

    Narayanan, Aravind; Lal, Chandar; Al-Sinawi, Hamed

    2017-01-01

    Objectives This study aimed to review general anaesthesia protocols for patients undergoing electroconvulsive therapy (ECT) at a tertiary care hospital in Oman, particularly with regards to clinical profile, potential drug interactions and patient outcomes. Methods This retrospective study took place at the Sultan Qaboos University Hospital (SQUH), Muscat, Oman. The electronic medical records of patients undergoing ECT at SQUH between January 2010 and December 2014 were reviewed for demographic characteristics and therapy details. Results A total of 504 modified ECT sessions were performed on 57 patients during the study period. All of the patients underwent a uniform general anaesthetic regimen consisting of propofol and succinylcholine; however, they received different doses between sessions, as determined by the treating anaesthesiologist. Variations in drug doses between sessions in the same patient could not be attributed to any particular factor. Self-limiting tachycardia and hypertension were periprocedural complications noted among all patients. One patient developed aspiration pneumonitis (1.8%). Conclusion All patients undergoing ECT received a general anaesthetic regimen including propofol and succinylcholine. However, the interplay of anaesthetic drugs with ECT efficacy could not be established due to a lack of comprehensive data, particularly with respect to seizure duration. In addition, the impact of concurrent antipsychotic therapy on anaesthetic dose and subsequent complications could not be determined. PMID:28417028

  2. Clinical efficacy of flumetasone/salicylic acid ointment combined with 308-nm excimer laser for treatment of psoriasis vulgaris.

    PubMed

    Dong, Jie; He, Yanling; Zhang, Xiuying; Wang, Yixuan; Tian, Yongjing; Wang, Jie

    2012-06-01

    To compare the clinical efficacy and safety of combining flumetasone ointment with 308-nm excimer laser therapy vs. 308-nm excimer laser monotherapy for the treatment of psoriasis vulgaris. Forty patients with psoriasis vulgaris were recruited; 20 were treated with flumetasone ointment plus 308-nm excimer laser therapy, and the other 20 received only excimer laser monotherapy. The flumetasone ointment was applied topically twice a day, and laser treatments were scheduled twice weekly for a total of 10 treatments. Clinical efficacy was evaluated in a blinded manner by two independent physicians using photographs taken before and after treatment. Of the 40 patients who received and completed the entire course of therapy, the psoriasis area and severity index score was improved by 82.51 ± 11.24% and 72.01 ± 20.94% in the combination group and laser group, respectively (P > 0.05), and the average cumulative dose was 5.06 ± 2.20 j/cm(2) in the combination group and 7.75 ± 2.25 j/cm(2) in the laser-only group, respectively (P < 0.05). The clinical data suggest that combination treatment using flumetasone ointment and a 308-nm excimer laser is superior to laser monotherapy for treatment of psoriasis vulgaris. The combination therapy can increase effectiveness and decrease the total laser dose, thus potentially reducing side effects. © 2012 John Wiley & Sons A/S.

  3. [Application of half-dose depot long-acting triptorelin in postoperative adjuvant therapy for endometriosis].

    PubMed

    Liu, Xia; Zhang, Hong-xia; Wang, Li-ping; Fu, Wei-ping

    2013-01-15

    To evaluate the efficacy and adverse effects of half-dose depot long-acting triptorelin in the therapy of endometriosis. The efficacy and adverse effects of routine-dose or half-dose triptorelin in postoperative endometriosis patients were prospectively observed. A total of 186 postoperative patients with moderate or severe endometriosis received an intramuscular injection of triptorelin every 28 days for 6 times. They were randomly divided into 3 groups, i.e. half-dose group (n = 99): 1.875 mg each time; "draw-back" group (n = 52): 3.75 mg first time, then 1.875 mg each time; and routine-dose group (n = 35): 3.75 mg each time. Amenorrhea was effectively induced in all patients after the second injection. There was no significant difference in the rate of serum E2 level at Day 28 of every injection below the upper limit of "estrogen threshold (110 - 146 pmol/L)" not stimulating ectopic endometrium proliferation among half-dose group, "draw-back" group and routine-dose group (99% vs 100% and 99.0%, P > 0.05), the percentage of E2 < 37 pmol/L in E2 < 110 pmol/L in half-dose group was significantly lower than that in "draw-back" and routine-dose groups after 2-5(th) injection (69% vs 79% and 85%, P < 0.01), but there was no significant difference after first half-dose and routine-dose injection (71% vs 73%, P > 0.05). No significant difference existed in the rate of pelvic pain relief during the first returning menstruation and the recurrence rate of endometriosis within 1 year postoperation among three groups (both P > 0.05). However, the incidences of menopausal syndrome and severe menopausal syndrome in half-dose group were significantly lower than those in "draw-back" and routine-dose groups (both P < 0.01). And the incompletion rate of six-time drug for severe menopause syndrome was also significantly lower (P < 0.05) while the completion rate of six-time drug use in half-dose group was significantly higher (P < 0.05). As a postoperative adjuvant, half-dose depot triptorelin therapy is efficacious for endometriosis. It reduces menopausal syndrome and treatment cost and enhances patient compliance.

  4. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT).

    PubMed

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham

    2013-12-01

    Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147-53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose-volume histogram (DVH) doses were consistently lower. The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques.

  5. Combined low-dose aspirin and warfarin anticoagulant therapy of postoperative atrial fibrillation following mechanical heart valve replacement.

    PubMed

    Wang, Jian-tang; Dong, Ming-feng; Song, Guang-min; Ma, Zeng-shan; Ma, Sheng-jun

    2014-12-01

    The safety and efficacy of combined low dose aspirin and warfarin therapy in patients with atrial fibrillation after mechanical heart valve replacement were evaluated. A total of 1016 patients (620 females, mean age of 36.8±7.7 years) admitted for cardiac valve replacement and complicated with atrial fibrillation after surgery were randomly divided into study (warfarin plus 75-100 mg aspirin) or control (warfarin only) groups. International normalized ratio (INR) and prothrombin time were maintained at 1.8-2.5 and 1.5-2.0 times the normal values, respectively. Thromboembolic events and major bleedings were registered during the follow-up period. Patients were followed up for 24±9 months. The average dose of warfarin in the study and control groups was 2.91±0.83 mg and 2.88±0.76 mg, respectively (P>0.05). The incidence of overall thromboembolic events in study group was lower than that in control group (2.16% vs. 4.35%, P=0.049). No statistically significant differences were found in hemorrhage events (3.53% vs. 3.95%, P=0.722) or mortality (0.20% vs. 0.40%, P=0.559) between the two groups. Combined low dose aspirin and warfarin therapy in the patients with atrial fibrillation following mechanical heart valve replacement significantly decreased thromboembolic events as compared with warfarin therapy alone. This combined treatment was not associated with an increase in the risk of major bleeding or mortality.

  6. A Phase I/II Trial of Gefitinib Given Concurrently With Radiotherapy in Patients With Nonmetastatic Prostate Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joensuu, Greetta; International Comprehensive Cancer Center Docrates, Helsinki; Joensuu, Timo

    Purpose: To estimate the safety and tolerability of daily administration of 250 mg of gefitinib given concurrently with three-dimensional conformal radiotherapy for patients with nonmetastatic prostate cancer. Methods and Materials: A total of 42 patients with T2-T3N0M0 tumors were treated in a nonrandomized single-center study. A prostate-specific antigen (PSA) level of <20 and a good performance status (WHO, 0-1) were required. Adjuvant or neoadjuvant hormone treatments were not allowed. A daily regimen of 250 mg of gefitinib was started 1 week before radiation therapy began and lasted for the duration of radiation therapy. A dose of 50.4 Gy (1.8 Gy/day)more » was administered to the tumor, prostate, and seminal vesicles, followed by a 22-Gy booster (2 Gy/day) for a total dose of 72.4 Gy. Correlative studies included analysis of epidermal growth factor receptor (EGFR), EGFRvIII, and phosphorylated EGFR in tumors and tumor necrosis factor, interleukin-1{alpha} (IL-1{alpha}), and IL-6 in serum. Results: Maximum tolerated dose was not reached in phase I (12 patients), and 30 additional patients were treated in phase II. Thirty (71.4%) patients completed trial medication. Dose-limiting toxicities were recorded for 16 (38.1%) patients, the most common of which was a grade 3 to 4 increase in transaminase (6 patients). After a median follow-up of 38 months, there were no deaths due to prostate cancer. The estimated PSA relapse-free survival rate at 4 years (Kaplan-Meier) was 97%, the salvage therapy-free survival rate was 91%, and the overall survival rate was 87%. These figures compared favorably with those of matched patients treated with radiation only at higher doses. Conclusions: The combination of gefitinib and radiation is reasonably well tolerated and has promising activity against nonmetastatic prostate cancer.« less

  7. Perioperative Interstitial High-Dose-Rate Brachytherapy for the Treatment of Recurrent Keloids: Feasibility and Early Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, Ping, E-mail: ping.jiang@uksh.de; Baumann, René; Dunst, Juergen

    Purpose: To prospectively evaluate high-dose-rate brachytherapy in the treatment of therapy-resistant keloids and report first results, with emphasis on feasibility and early treatment outcome. Methods and Materials: From 2009 to 2014, 24 patients with 32 recurrent keloids were treated with immediate perioperative high-dose-rate brachytherapy; 3 patients had been previously treated with adjuvant external beam radiation therapy and presented with recurrences in the pretreated areas. Two or more different treatment modalities had been tried in all patients and had failed to achieve remission. After (re-)excision of the keloids, a single brachytherapy tube was placed subcutaneously before closing the wound. The target volumemore » covered the scar in total length. Brachytherapy was given in 3 fractions with a single dose of 6 Gy in 5 mm tissue depth. The first fraction was given within 6 hours after surgery, the other 2 fractions on the first postoperative day. Thus, a total dose of 18 Gy in 3 fractions was administered within 36 hours after the resection. Results: The treatment was feasible in all patients. No procedure-related complications (eg, secondary infections) occurred. Nineteen patients had keloid-related symptoms before treatment like pain and pruritus; disappearance of symptoms was noticed in all patients after treatment. After a median follow-up of 29.4 months (range, 7.9-72.4 months), 2 keloid recurrences and 2 mildly hypertrophied scars were observed. The local control rate was 94%. Pigmentary abnormalities were detected in 3 patients, and an additional 6 patients had a mild delay in the wound-healing process. Conclusions: The early results of this study prove the feasibility and the efficacy of brachytherapy for the prevention of keloids. The results also suggest that brachytherapy may be advantageous in the management of high-risk keloids or as salvage treatment for failure after external beam therapy.« less

  8. Radiation therapy dose is associated with improved survival for unresected anaplastic thyroid carcinoma: Outcomes from the National Cancer Data Base.

    PubMed

    Pezzi, Todd A; Mohamed, Abdallah S R; Sheu, Tommy; Blanchard, Pierre; Sandulache, Vlad C; Lai, Stephen Y; Cabanillas, Maria E; Williams, Michelle D; Pezzi, Christopher M; Lu, Charles; Garden, Adam S; Morrison, William H; Rosenthal, David I; Fuller, Clifton D; Gunn, G Brandon

    2017-05-01

    The outcomes of patients with unresected anaplastic thyroid carcinoma (ATC) from the National Cancer Data Base (NCDB) were assessed, and potential correlations were explored between radiation therapy (RT) dose and overall survival (OS). The study cohort was comprised of patients who underwent either no surgery or grossly incomplete resection. Correlates of OS were explored using univariate analysis and multivariable analysis (MVA). In total, 1288 patients were analyzed. The mean patient age was 70.2 years, 59.7% of patients were women, and 47.6% received neck RT. The median OS was 2.27 months, and 11% of patients remained alive at 1 year. A positive RT dose-survival correlation was observed for the entire study cohort, for those who received systemic therapy, and for those with stage IVA/IVB and IVC disease. On MVA, older age (hazard ratio [HR], 1.317; 95% confidence interval [CI], 1.137-1.526), ≥ 1 comorbidity (HR, 1.587; 95% CI, 1.379-1.827), distant metastasis (HR, 1.385; 95% CI, 1.216-1.578), receipt of systemic therapy (HR, 0.637; 95% CI, 0.547-0.742), and receipt of RT compared with no RT (<45 grays [Gy]:HR, 0.843; 95% CI, 0.718-0.988; 45-59.9 Gy: HR, 0.596; 95% CI, 0.479-0.743; 60-75 Gy: HR, 0.419; 95% CI, 0.339-0.517) correlated with OS. The RT dose-survival correlation for patients who received higher (60-75 Gy) versus lower (45-59.9 Gy) therapeutic doses was confirmed by propensity-score matching. Survival was poor in this cohort of patients with unresected ATC, and more effective therapies are needed. However, the association of RT dose with OS highlights the importance of identifying patients with unresected ATC who may still yet benefit from multimodal locoregional treatment that incorporates higher dose RT. Cancer 2017;123:1653-1661. © 2017 American Cancer Society. © 2016 American Cancer Society.

  9. Low-dose vincristine in the treatment of corticosteroid-refractory idiopathic thrombocytopenic purpura (ITP) in non-splenectomized patients.

    PubMed Central

    Cervantes, F.; Montserrat, E.; Rozman, C.; Diumenjo, C.; Feliu, E.; Grañena, A.

    1980-01-01

    Eight non-splenectomized patients with corticosteroid-refractory idiopathic thrombocytopenic purpura (ITP) were treated with low-dose vincristine (1 mg/week up to a total dose of 4 mg). Complete remission was achieved in 2 cases and partial remission in 3. Bleeding stopped in one patient who failed to remit. No statistical relationship was found between the response to vincristine and the duration of the disease or the corticosteroid-therapy. Side effects were only observed in one patient. By comparing these results with those reported in the literature, it can be inferred that low-dose vincristine may be useful in the management of corticosteroid-refractory ITP. PMID:7194478

  10. Salicylate-induced enzymuria: comparison with other anti-inflammatory agents.

    PubMed

    Proctor, R A; Kunin, C M

    1978-12-01

    N-acetyl-beta glucosaminidase (NAG) enzymuria was used as a marker of renal injury in patients with rheumatic disease. An elevated NAG level was particularly common in patients receiving gold or aspirin therapy. The multiplicity of drugs received and the unknown role of underlying disease in these patients led to a study in healthy volunteers. Customary therapeutic doses of aspirin, choline salicylate, ibuprofen, indomethacin and acetaminophen did not produce enzymuria. Large single doses of salicylates equivalent to 6 tablets of aspirin consistently did produce enzymuria. The size of the individual dose in relation to body weight was more important than the total daily dose. NAG enzymuria appears to be a sensitive tool for identifying potentially nephrotoxic drugs.

  11. SU-E-T-585: Optically-Stimulated Luminescent Dosimeters for Monitoring Pacemaker Dose in Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Apicello, L; Riegel, A; Jamshidi, A

    2015-06-15

    Purpose: A sufficient amount of ionizing radiation can cause failure to components of pacemakers. Studies have shown that permanent damage can occur after a dose of 10 Gy and minor damage to functionality occurs at doses as low as 2 Gy. Optically stimulated thermoluminescent dosimeters (OSLDs) can be used as in vivo dosimeters to predict dose to be deposited throughout the treatment. The purpose of this work is to determine the effectiveness of using OSLDs for in vivo dosimetry of pacemaker dose. Methods: As part of a clinical in vivo dosimetry experience, OSLDs were placed at the site of themore » pacemaker by the therapist for one fraction of the radiation treatment. OSLD measurements were extrapolated to the total dose to be received by the pacemaker during treatment. A total of 79 measurements were collected from November 2011 to December 2013 on six linacs. Sixty-six (66) patients treated in various anatomical sites had the dose of their pacemakers monitored. Results: Of the 79 measurements recorded, 76 measurements (96 %) were below 2 Gy. The mean and standard deviation were 50.12 ± 76.41 cGy. Of the 3 measurements that exceeded 2 Gy, 2 measurements matched the dose predicted in the treatment plan and 1 was repeated after an unexpectedly high Result. The repeated measurement yielded a total dose less than 2 Gy. Conclusion: This analysis suggests OSLDs may be used for in vivo monitoring of pacemaker dose. Further research should be performed to assess the effect of increased backscatter from the pacemaker device.« less

  12. A comprehensive study on the relationship between the image quality and imaging dose in low-dose cone beam CT

    NASA Astrophysics Data System (ADS)

    Yan, Hao; Cervino, Laura; Jia, Xun; Jiang, Steve B.

    2012-04-01

    While compressed sensing (CS)-based algorithms have been developed for the low-dose cone beam CT (CBCT) reconstruction, a clear understanding of the relationship between the image quality and imaging dose at low-dose levels is needed. In this paper, we qualitatively investigate this subject in a comprehensive manner with extensive experimental and simulation studies. The basic idea is to plot both the image quality and imaging dose together as functions of the number of projections and mAs per projection over the whole clinically relevant range. On this basis, a clear understanding of the tradeoff between the image quality and imaging dose can be achieved and optimal low-dose CBCT scan protocols can be developed to maximize the dose reduction while minimizing the image quality loss for various imaging tasks in image-guided radiation therapy (IGRT). Main findings of this work include (1) under the CS-based reconstruction framework, image quality has little degradation over a large range of dose variation. Image quality degradation becomes evident when the imaging dose (approximated with the x-ray tube load) is decreased below 100 total mAs. An imaging dose lower than 40 total mAs leads to a dramatic image degradation, and thus should be used cautiously. Optimal low-dose CBCT scan protocols likely fall in the dose range of 40-100 total mAs, depending on the specific IGRT applications. (2) Among different scan protocols at a constant low-dose level, the super sparse-view reconstruction with the projection number less than 50 is the most challenging case, even with strong regularization. Better image quality can be acquired with low mAs protocols. (3) The optimal scan protocol is the combination of a medium number of projections and a medium level of mAs/view. This is more evident when the dose is around 72.8 total mAs or below and when the ROI is a low-contrast or high-resolution object. Based on our results, the optimal number of projections is around 90 to 120. (4) The clinically acceptable lowest imaging dose level is task dependent. In our study, 72.8 mAs is a safe dose level for visualizing low-contrast objects, while 12.2 total mAs is sufficient for detecting high-contrast objects of diameter greater than 3 mm.

  13. Gadolinium as a Neutron Capture Therapy Agent

    NASA Astrophysics Data System (ADS)

    Shih, Jing-Luen Allen

    The clinical results of treating brain tumors with boron neutron capture therapy are very encouraging and researchers around the world are once again making efforts to develop this therapeutic modality. Boron-10 is the agent receiving the most attention for neutron capture therapy but ^{157}Gd is a nuclide that also holds interesting properties of being a neutron capture therapy agent. The objective of this study is to evaluate ^{157}Gd as a neutron capture therapy agent. In this study it is determined that tumor concentrations of about 300 mug ^{157}Gd/g tumor can be achieved in brain tumors with some FDA approved MRI contrast agents such as Gd-DTPA and Gd-DOTA, and up to 628 mug ^{157 }Gd/g tumor can be established in bone tumors with Gd-EDTMP. Monte Carlo calculations show that with only 250 ppm of ^{157}Gd in tumor, neutron capture therapy can deliver 2,000 cGy to a tumor of 2 cm diameter or larger with 5 times 10^{12} n/cm ^2 fluence at the tumor. Dose measurements which were made with films and TLD's in phantoms verified these calculations. More extended Monte Carlo calculations demonstrate that neutron capture therapy with Gd possesses comparable dose distribution to B neutron capture therapy. With 5 times 10^{12 } n/cm^2 thermal neutrons at the tumor, Auger electrons from the Gd produced an optical density enhancement on the films that is similar to the effect caused by about 300 cGy of Gd prompt gamma dose which will further enhance the therapeutic effects. A technique that combines brachytherapy with Gd neutron capture therapy has been evaluated. Monte Carlo calculations show that 5,000 cGy of prompt gamma dose can be delivered to a treatment volume of 40 cm^3 with a 3-plane implant of a total of 9 Gd needles. The tumor to normal tissue advantage of this method is as good as ^{60} Co brachytherapy. Measurements of prompt gamma dose with films and TLD-700's in a lucite phantom verify the Monte Carlo evaluation. A technique which displays the Gd distribution and its relative concentration in samples has been developed. Concentrations of ^{157}Gd in samples range from 20 ppm to 500 ppm can be determined with this technique. The intrinsic spatial resolution of the imaging system in 70 mum.

  14. Dose reduction of scattered photons from concrete walls lined with lead: Implications for improvement in design of megavoltage radiation therapy facility mazes.

    PubMed

    Al-Affan, I A M; Hugtenburg, R P; Bari, D S; Al-Saleh, W M; Piliero, M; Evans, S; Al-Hasan, M; Al-Zughul, B; Al-Kharouf, S; Ghaith, A

    2015-02-01

    This study explores the possibility of using lead to cover part of the radiation therapy facility maze walls in order to absorb low energy photons and reduce the total dose at the maze entrance of radiation therapy rooms. Experiments and Monte Carlo simulations were utilized to establish the possibility of using high-Z materials to cover the concrete walls of the maze in order to reduce the dose of the scattered photons at the maze entrance. The dose of the backscattered photons from a concrete wall was measured for various scattering angles. The dose was also calculated by the FLUKA and EGSnrc Monte Carlo codes. The FLUKA code was also used to simulate an existing radiotherapy room to study the effect of multiple scattering when adding lead to cover the concrete walls of the maze. Monoenergetic photons were used to represent the main components of the x ray spectrum up to 10 MV. It was observed that when the concrete wall was covered with just 2 mm of lead, the measured dose rate at all backscattering angles was reduced by 20% for photons of energy comparable to Co-60 emissions and 70% for Cs-137 emissions. The simulations with FLUKA and EGS showed that the reduction in the dose was potentially even higher when lead was added. One explanation for the reduction is the increased absorption of backscattered photons due to the photoelectric interaction in lead. The results also showed that adding 2 mm lead to the concrete walls and floor of the maze reduced the dose at the maze entrance by up to 90%. This novel proposal of covering part or the entire maze walls with a few millimeters of lead would have a direct implication for the design of radiation therapy facilities and would assist in upgrading the design of some mazes, especially those in facilities with limited space where the maze length cannot be extended to sufficiently reduce the dose. © 2015 American Association of Physicists in Medicine.

  15. Dose reduction of scattered photons from concrete walls lined with lead: Implications for improvement in design of megavoltage radiation therapy facility mazes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Al-Affan, I. A. M., E-mail: info@medphys-environment.co.uk; Hugtenburg, R. P.; Piliero, M.

    Purpose: This study explores the possibility of using lead to cover part of the radiation therapy facility maze walls in order to absorb low energy photons and reduce the total dose at the maze entrance of radiation therapy rooms. Methods: Experiments and Monte Carlo simulations were utilized to establish the possibility of using high-Z materials to cover the concrete walls of the maze in order to reduce the dose of the scattered photons at the maze entrance. The dose of the backscattered photons from a concrete wall was measured for various scattering angles. The dose was also calculated by themore » FLUKA and EGSnrc Monte Carlo codes. The FLUKA code was also used to simulate an existing radiotherapy room to study the effect of multiple scattering when adding lead to cover the concrete walls of the maze. Monoenergetic photons were used to represent the main components of the x ray spectrum up to 10 MV. Results: It was observed that when the concrete wall was covered with just 2 mm of lead, the measured dose rate at all backscattering angles was reduced by 20% for photons of energy comparable to Co-60 emissions and 70% for Cs-137 emissions. The simulations with FLUKA and EGS showed that the reduction in the dose was potentially even higher when lead was added. One explanation for the reduction is the increased absorption of backscattered photons due to the photoelectric interaction in lead. The results also showed that adding 2 mm lead to the concrete walls and floor of the maze reduced the dose at the maze entrance by up to 90%. Conclusions: This novel proposal of covering part or the entire maze walls with a few millimeters of lead would have a direct implication for the design of radiation therapy facilities and would assist in upgrading the design of some mazes, especially those in facilities with limited space where the maze length cannot be extended to sufficiently reduce the dose.« less

  16. In vivo quality assurance of volumetric modulated arc therapy for ano-rectal cancer with thermoluminescent dosimetry and image-guidance.

    PubMed

    Dipasquale, Giovanna; Nouet, Philippe; Rouzaud, Michel; Dubouloz, Angèle; Miralbell, Raymond; Zilli, Thomas

    2014-06-01

    To assess in vivo dose distribution using cone-beam computed tomography scans (CBCTs) and thermoluminescent dosimeters (TLDs) in patients with anal or rectal cancer treated with volumetric modulated arc therapy (VMAT). Intracavitary (IC) in vivo dosimetry (IVD) was performed in 11 patients using adapted endorectal probes containing TLDs, with extra measurements at the perianal skin (PS) for anal margin tumors. Measured doses were compared to calculated ones obtained from image fusion of CBCT with CT treatments plans. A total of 55 IC and 6 PS measurements were analyzed. IC TLD median planned and measured doses were 1.81 Gy (range, 0.25-2.02 Gy) and 1.82 Gy (range, 0.19-2.12 Gy), respectively. In comparison to the planned doses all IC TLD dose measurements differed by a median dose of 0.02 Gy (range, -0.11/+0.19 Gy, p=0.102) (median difference of 1.1%, range -6.1%/+10.6%). Overall, 95% of IC measurements were within ±7.7% of the expected percentage doses and only 1 value was above +10%. For PS measurements, only one was not within ±7.7% of expected values (i.e., -8.9%). Image guidance using CBCT for IVD with TLDs is helpful to validate the delivered doses in patients treated with VMAT for ano-rectal tumors. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. Evaluation of a mixed beam therapy for post-mastectomy breast cancer patients: bolus electron conformal therapy combined with intensity modulated photon radiotherapy and volumetric modulated photon arc therapy.

    PubMed

    Zhang, Rui; Heins, David; Sanders, Mary; Guo, Beibei; Hogstrom, Kenneth

    2018-05-10

    The purpose of this study was to assess the potential benefits and limitations of a mixed beam therapy, which combined bolus electron conformal therapy (BECT) with intensity modulated photon radiotherapy (IMRT) and volumetric modulated photon arc therapy (VMAT), for left-sided post-mastectomy breast cancer patients. Mixed beam treatment plans were produced for nine post-mastectomy radiotherapy (PMRT) patients previously treated at our clinic with VMAT alone. The mixed beam plans consisted of 40 Gy to the chest wall area using BECT, 40 Gy to the supraclavicular area using parallel opposed IMRT, and 10 Gy to the total planning target volume (PTV) by optimizing VMAT on top of the BECT+IMRT dose distribution. The treatment plans were created in a commercial treatment planning system (TPS), and all plans were evaluated based on PTV coverage, dose homogeneity index (DHI), conformity index (CI), dose to organs at risk (OARs), normal tissue complication probability (NTCP), and secondary cancer complication probability (SCCP). The standard VMAT alone planning technique was used as the reference for comparison. Both techniques produced clinically acceptable PMRT plans but with a few significant differences: VMAT showed significantly better CI (0.70 vs. 0.53, p < 0.001) and DHI (0.12 vs. 0.20, p < 0.001) over mixed beam therapy. For normal tissues, mixed beam therapy showed better OAR sparing and significantly reduced NTCP for cardiac mortality (0.23% vs. 0.80%, p = 0.01) and SCCP for contralateral breast (1.7% vs. 3.1% based on linear model, and 1.2% vs. 1.9% based on linear-exponential model, p < 0.001 in both cases), but showed significantly higher mean (50.8 Gy vs. 49.3 Gy, p < 0.001) and maximum skin doses (59.7 Gy vs. 53.3 Gy, p < 0.001) compared with VMAT. Patients with more tissue (minimum distance between the distal PTV surface and lung approximately > 0.5 cm and volume of tissue between the distal PTV surface and heart or lung approximately > 250 cm 3 ) between distal PTV surface and lung may benefit the most from mixed beam therapy. This work has demonstrated that mixed beam therapy (BECT+IMRT : VMAT = 4 : 1) produces clinically acceptable plans having reduced OAR doses and risks of side effects compared with VMAT. Even though VMAT alone produces more homogenous and conformal dose distributions, mixed beam therapy remains as a viable option for treating post-mastectomy patients, possibly leading to reduced normal tissue complications. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  18. Efficacy of clonidine versus phenobarbital in reducing neonatal morphine sulfate therapy days for neonatal abstinence syndrome. A prospective randomized clinical trial.

    PubMed

    Surran, B; Visintainer, P; Chamberlain, S; Kopcza, K; Shah, B; Singh, R

    2013-12-01

    To compare the efficacy of clonidine versus phenobarbital in reducing morphine sulfate treatment days for neonatal abstinence syndrome (NAS). Prospective, non-blinded, block randomized trial at a single level III NICU (Neonatal Intensive Care Unit). Eligible infants were treated with a combination of medications as per protocol. Primary outcome was treatment days with morphine sulfate. Secondary outcomes were the mean total morphine sulfate dose, outpatient phenobarbital days, adverse events and treatment failures. A total of 82 infants were eligible, of which 68 were randomized with 34 infants in each study group. Adjusting for covariates phenobarbital as compared with clonidine had shorter morphine sulfate treatment days (-4.6, 95% confidence interval (CI): -0.3, -8.9; P=0.037) with no difference in average morphine sulfate total dose (1.1 mg kg(-1), 95% CI: -0.1, 2.4; P=0.069). Post-discharge phenobarbital was continued for an average of 3.8 months (range 1 to 8 months). No other significant differences were noted. Phenobarbital as adjunct had clinically nonsignificant shorter inpatient but significant overall longer therapy time as compared with clonidine.

  19. Quantification of incidental mediastinal and hilar irradiation delivered during definitive stereotactic body radiation therapy for peripheral non-small cell lung cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, Kate L.; Gomez, Jorge; Nazareth, Daryl P.

    2012-07-01

    To determine the amount of incidental radiation dose received by the mediastinal and hilar nodes for patients with non-small cell lung cancer (NSCLC) treated with stereotactic body radiation therapy (SBRT). Fifty consecutive patients with NSCLC, treated using an SBRT technique, were identified. Of these patients, 38 had a prescription dose of 60 Gy in 20-Gy fractions and were eligible for analysis. For each patient, ipsilateral upper (level 2) and lower (level 4) paratracheal, and hilar (level 10) nodal regions were contoured on the planning computed tomography (CT) images. Using the clinical treatment plan, dose and volume calculations were performed retrospectivelymore » for each nodal region. SBRT to upper lobe tumors resulted in an average total ipsilateral mean dose of between 5.2 and 7.8 Gy for the most proximal paratracheal nodal stations (2R and 4R for right upper lobe lesions, 2L and 4L for left upper lobe lesions). SBRT to lower lobe tumors resulted in an average total ipsilateral mean dose of between 15.6 and 21.5 Gy for the most proximal hilar nodal stations (10R for right lower lobe lesions, 10 l for left lower lobe lesions). Doses to more distal nodes were substantially lower than 5 Gy. The often substantial incidental irradiation, delivered during SBRT for peripheral NSCLC of the lower lobes to the most proximal hilar lymph nodes may be therapeutic for low-volume, subclinical nodal disease. Treatment of peripheral upper lobe lung tumors delivers less incidental irradiation to the paratracheal lymph nodes with lower likelihood of therapeutic benefit.« less

  20. A phase IB study of ipilimumab with peginterferon alfa-2b in patients with unresectable melanoma.

    PubMed

    Brohl, Andrew S; Khushalani, Nikhil I; Eroglu, Zeynep; Markowitz, Joseph; Thapa, Ram; Chen, Y Ann; Kudchadkar, Ragini; Weber, Jeffrey S

    2016-01-01

    Ipilimumab and peginterferon alfa-2b are established systemic treatment options for melanoma that have distinct mechanisms of action. Given the need for improved therapies for advanced melanoma, we conducted an open-label, single institution, phase Ib study to assess the safety and tolerability of using these two agents in combination. Study treatment consisted of ipilimumab given every 3 weeks, for a total of four infusions, concurrent with peginterferon alfa-2b administered subcutaneous weekly for a total of 12 weeks. This was followed by maintenance therapy with peginterferon alfa-2b administered subcutaneously weekly for up to 144 additional weeks. The study was designed as a two-stage dose escalation scheme with continuous dose-limiting toxicity monitoring during the induction phase. Thirty one patients received at least 1 dose of study treatment and 30 were assessable for efficacy endpoints. We found that ipilimumab at 3 mg/kg dosing with peginterfeon alfa-2b at 2 μg/kg/week was the maximum tolerated dose of this combination. The incidence of grade 3 drug-related adverse events (AEs) was 45.2%. There were no grade 4/5 AEs. The overall response rate was 40% by immune-related response criteria. Median progression-free survival was 5.9 months. The median overall survival was not reached with at a median follow-up of 35.8 months. We report that the combination of ipilimumab at 3 mg/kg dosing combined with peginterfeon alfa-2b at 2 μg/kg/week demonstrated an acceptable toxicity profile and a promising efficacy signal. Further study of this combination is warranted. ClinicalTrials.gov identifier: NCT01496807, Registered December 19th, 2011.

  1. Improved long-term survival after intra-operative single high-dose ATG-Fresenius induction in renal transplantation: a single centre experience.

    PubMed

    Kaden, Jürgen; May, Gottfried; Völp, Andreas; Wesslau, Claus

    2009-01-01

    In organ grafts donor-specific sensitization is initiated immediately after revascularization. Therefore, in 1990 we introduced the intra-operative single high-dose ATG-Fresenius (ATG-F) induction in addition to standard triple drug therapy (TDT) consisting of steroids, azathioprine and cyclosporin. A total of 778 first renal transplantations from deceased donors, performed between 1987 and 1998, were included in this evaluation. This retrospective analysis of clinic records and electronic databases presents data of all recipients of first kidney grafts who received two different ATG-F inductions (1(st) group: 9 mg/kg body weight as single high-dose intra-operatively, n=484; 2(nd) group: 3 mg/kg body weight on 7 or 8 consecutive days as multiple-dose starting also intra-operatively, n=78) and standard TDT alone (3(rd) group: TDT alone, n=216). The 10-year patient survival rates were 72.6+/-2.6% (TDT + ATG-F single high-dose), 79.5+/-5.1% (TDT + ATG-F multiple-dose) and 67.2+/-3.7%% (TDT alone; Kaplan-Meier estimates with standard errors; ATG-F vs TDT alone, p=0.001). The 10-year graft survival rates with censoring of patients that died with a functioning graft were 73.8+/-2.4%, 57.7+/-5.8% and 58.4+/-3.6% (Kaplan-Meier estimates with standard errors; 1(st) vs 2(nd )and 3(rd) group, respectively, p<0.001) and the 10-year graft survival rates with patient death counted as graft failure were 58.3+/-2.7%, 55.7+/-5.8% and 48.2+/-3.5% (Kaplan-Meier estimates with standard errors; ATG-F single high-dose vs TDT, p=0.023). In pre-sensitized recipients there were also significant differences in favour of ATG-F, more notably in the single high-dose ATG-F induction. A total of 69% of the patients in the two cohorts receiving ATG-F did not experience any transplant rejections compared to 56% in patients undergoing TDT alone (p=0.018). The incidence of infectious complications was comparable across all groups. According to evidence obtained from the routine documentation of 778 renal transplantations, ATG-F induction therapy administered as a part of immunosuppressive therapy significantly improves patient survival and reduces the risk of graft failure and transplant rejections.

  2. Exposure of the Heart in Breast Cancer Radiation Therapy: A Systematic Review of Heart Doses Published During 2003 to 2013.

    PubMed

    Taylor, Carolyn W; Wang, Zhe; Macaulay, Elizabeth; Jagsi, Reshma; Duane, Frances; Darby, Sarah C

    2015-11-15

    Breast cancer radiation therapy cures many women, but where the heart is exposed, it can cause heart disease. We report a systematic review of heart doses from breast cancer radiation therapy that were published during 2003 to 2013. Eligible studies were those reporting whole-heart dose (ie, dose averaged over the whole heart). Analyses considered the arithmetic mean of the whole-heart doses for the CT plans for each regimen in each study. We termed this "mean heart dose." In left-sided breast cancer, mean heart dose averaged over all 398 regimens reported in 149 studies from 28 countries was 5.4 Gy (range, <0.1-28.6 Gy). In regimens that did not include the internal mammary chain (IMC), average mean heart dose was 4.2 Gy and varied with the target tissues irradiated. The lowest average mean heart doses were from tangential radiation therapy with either breathing control (1.3 Gy; range, 0.4-2.5 Gy) or treatment in the lateral decubitus position (1.2 Gy; range, 0.8-1.7 Gy), or from proton radiation therapy (0.5 Gy; range, 0.1-0.8 Gy). For intensity modulated radiation therapy mean heart dose was 5.6 Gy (range, <0.1-23.0 Gy). Where the IMC was irradiated, average mean heart dose was around 8 Gy and varied little according to which other targets were irradiated. Proton radiation therapy delivered the lowest average mean heart dose (2.6 Gy, range, 1.0-6.0 Gy), and tangential radiation therapy with a separate IMC field the highest (9.2 Gy, range, 1.9-21.0 Gy). In right-sided breast cancer, the average mean heart dose was 3.3 Gy based on 45 regimens in 23 studies. Recent estimates of typical heart doses from left breast cancer radiation therapy vary widely between studies, even for apparently similar regimens. Maneuvers to reduce heart dose in left tangential radiation therapy were successful. Proton radiation therapy delivered the lowest doses. Inclusion of the IMC doubled typical heart dose. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. A phase I/pharmacokinetic study of sunitinib in combination with highly active antiretroviral therapy (HAART) in HIV-positive patients with cancer: AIDS Malignancy Consortium Trial AMC 061

    PubMed Central

    Rudek, Michelle A; Moore, Page C.; Mitsuyasu, Ronald T.; Dezube, Bruce J.; Aboulafia, David; Gerecitano, John; Sullivan, Ryan; Cianfrocca, Mary E.; Henry, David H.; Ratner, Lee; Haigentz, Missak; Dowlati, Afshin; Little, Richard F.; Ivy, S. Percy; Deeken, John F.

    2014-01-01

    Background Treatment of non-AIDS defining cancers (NADCs) may be complicated by drug interactions between highly active antiretroviral therapy (HAART) and chemotherapy. This trial is the first by the AIDS Malignancy Consortium assessing targeted therapies and HAART in HIV+ cancer patients (ClinicalTrials.gov NCT00890747). Methods Patients were stratified into two arms based on whether they were taking ritonavir, a potent CYP3A4 inhibitor, in a modified phase I study of sunitinib. Patients in arm 1 (non-ritonavir HAART) received standard sunitinib dosing (50mg/day). Arm 2 (ritonavir-based HAART) used a phase I, 3+3 dose escalation design (from 25 to 50mg/day). Cycles were with four weeks on treatment followed by a two week break (6 weeks total). Pharmacokinetics of sunitinib and its active metabolite (N-desethyl sunitinib) were assessed. Results Nineteen patients were enrolled and evaluable. Patients on Arm 1 tolerated treatment with one observed dose limiting toxicity (DLT). In Arm 2, a DLT was experienced at 37.5mg, and an additional 3 of 5 patients experienced grade 3 neutropenia, an uncommon toxicity of sunitinib. No patient had a response, but 10 had stable disease, including 8 with prolonged disease stability. Efavirenz, a potent inducer of CYP3A4, resulted in increased exposure of N-desethyl sunitinib, whereas ritonavir caused decreased exposure of the metabolite. Hand-foot syndrome was associated with higher steady-state trough concentrations of sunitinib. Conclusions Patients on non-ritonavir based HAART regimens tolerated standard dosing of sunitinib. Patients on ritonavir-based therapy treated with 37.5mg/day experienced higher toxicities. Dose reduction of sunitinib to 37.5mg may be warranted in patients on ritonavir. PMID:24474568

  4. Radiation Therapy for Primary Cutaneous Anaplastic Large Cell Lymphoma: An International Lymphoma Radiation Oncology Group Multi-institutional Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Million, Lynn, E-mail: lmillion@stanford.edu; Yi, Esther J.; Wu, Frank

    Purpose: To collect response rates of primary cutaneous anaplastic large cell lymphoma, a rare cutaneous T-cell lymphoma, to radiation therapy (RT), and to determine potential prognostic factors predictive of outcome. Methods and Materials: The study was a retrospective analysis of patients with primary cutaneous anaplastic large cell lymphoma who received RT as primary therapy or after surgical excision. Data collected include initial stage of disease, RT modality (electron/photon), total dose, fractionation, response to treatment, and local recurrence. Radiation therapy was delivered at 8 participating International Lymphoma Radiation Oncology Group institutions worldwide. Results: Fifty-six patients met the eligibility criteria, and 63 tumorsmore » were treated: head and neck (27%), trunk (14%), upper extremities (27%), and lower extremities (32%). Median tumor size was 2.25 cm (range, 0.6-12 cm). T classification included T1, 40 patients (71%); T2, 12 patients (21%); and T3, 4 patients (7%). The median radiation dose was 35 Gy (range, 6-45 Gy). Complete clinical response (CCR) was achieved in 60 of 63 tumors (95%) and partial response in 3 tumors (5%). After CCR, 1 tumor recurred locally (1.7%) after 36 Gy and 7 months after RT. This was the only patient to die of disease. Conclusions: Primary cutaneous anaplastic large cell lymphoma is a rare, indolent cutaneous lymphoma with a low death rate. This analysis, which was restricted to patients selected for treatment with radiation, indicates that achieving CCR was independent of radiation dose. Because there were too few failures (<2%) for statistical analysis on dose response, 30 Gy seems to be adequate for local control, and even lower doses may suffice.« less

  5. Oral ifosfamide-mesna: a clinical investigation in advanced non-small-cell lung cancer.

    PubMed

    Manegold, C; Bischoff, H; Fischer, J R; Löchner, S; Peukert, M; Schmähl, A; Drings, P

    1992-11-01

    The purpose of this study was to evaluate the toxicity and response efficacy of fixed-dose oral ifosfamide (OI)-mesna (M) in advanced, non-small-cell lung cancer (NSCLC). OI was given in four different fractionated-dose treatment schedules with a total dose per cycle of either 3.0 g/m2, 6.0 g/m2, 7.5 g/m2 or 10 g/m2 (equivalent to a daily dose of either 750 mg, 1000 mg or 1250 mg.) M was given p.o. by drinking ampules. In the 64 patients (pts) included, a total of 305 treatment cycles were administered with no evidence of severe neurotoxicity. Twenty-two pts (37%) developed mild to moderate CNS toxicity. Neither myelosuppression, alopecia, gastrointestinal toxicity nor urotoxicity were clinical problems. On schedule 2 (6 g/m2), 3 of 14 evaluable pts (21%) had partial remissions (PR), and on schedule 3 (7.5 g/m2) 4 pts (25%) showed PRs. The median duration of response was 9 months (mts) for pts on schedule 2, and 8 mts for pts on schedule 3. We conclude that OIM can easily be tolerated in the same dose usually given intravenously (7.5 g/m2/mts), when patients at high risk for developing CNS toxicity have been previously excluded from therapy. In order to reduce CNS toxicity, it is suggested that the total dose per cycle should not exceed 7.5 g/m2 (1000 mg daily) within a fractionated-dose, 14-day treatment schedule. We further conclude that the tumor response efficacy of OIM in NSCLC is comparable to the one achieved by intravenously-administered IM, whereby the total monthly OI dose should not be less than 6.0 g/m2 (750 mg daily).

  6. Effects of Low Dose Metformin in Adolescents with Type I Diabetes Mellitus: A Randomized, Double-Blinded Placebo-Controlled Study

    PubMed Central

    Nadeau, Kristen; Chow, Kelsey; Alam, Lyla; Lindquist, Kara; Cambell, Sarah; McFann, Kim; Klingensmith, Georgeanna; Walravens, Phillipe

    2014-01-01

    Background Insulin resistance increases during adolescence in those with type 1 diabetes (T1DM), complicating glycemic control and potentially increasing cardiovascular disease (CVD) risk. Metformin, typically used in type 2 diabetes (T2DM), is a possible adjunct therapy in T1DM to help improve glycemic control and insulin sensitivity. Objective We hypothesized that metformin would improve metabolic parameters in adolescents with T1DM. Design, Setting, and Participants This randomized, double-blinded, placebo-controlled trial included 74 pubertal adolescents (ages 13–20 years) with T1DM. Participants were randomized to receive either metformin or placebo for six months. HbA1c, insulin dose, waist circumference, BMI, and blood pressure were measured at baseline, 3 and 6 months, with fasting lipids measured at baseline and 6 months. Results Total daily insulin dose, BMI Z-score and waist circumference significantly decreased at 3 and 6 months compared to baseline within the metformin group, even among normal-weight participants. In placebo group, total insulin dose and systolic blood pressure increased significantly at 3 months and total insulin dose increased significantly at 6 months. No significant change was observed in HbA1c at any time point between metformin and placebo groups or within either group. Conclusions Low-dose metformin likely improves BMI as well as insulin sensitivity in T1DM adolescents, as indicated by a decrease in total daily insulin dose. The decrease in waist circumference indicates that fat distribution is also likely impacted by metformin in T1DM. Further studies with higher metformin doses and more detailed measurements are needed to confirm these results, their underlying mechanisms, and potential impact on CVD in T1DM youth. PMID:24698216

  7. A phase I study of Foscan-mediated photodynamic therapy and surgery in patients with mesothelioma.

    PubMed

    Friedberg, Joseph S; Mick, Rosemarie; Stevenson, James; Metz, James; Zhu, Timothy; Buyske, Jo; Sterman, Daniel H; Pass, Harvey I; Glatstein, Eli; Hahn, Stephen M

    2003-03-01

    Photodynamic therapy (PDT) is a light-based cancer treatment that, in the correct setting, can be delivered intraoperatively as an adjuvant therapy. A phase I clinical trial combining surgical debulking with Foscan-mediated PDT was performed in patients with malignant pleural mesothelioma. The purpose of the study was to define the toxicities and to determine the maximally tolerated dose (MTD) of Foscan-mediated PDT. A total of 26 patients completed treatment. Tumor debulking was accomplished with either an extrapleural pneumonectomy (7 patients) or a lung-sparing pleurectomy-decortication (19 patients). Patients were injected with Foscan before surgery, and 652 nm light was delivered intraoperatively after completion of surgical debulking. Four light sensors were placed in the chest, allowing delivery of light to a uniform measured dose throughout the hemithorax. Four dose levels were explored. The MTD was 0.1 mg/kg of Foscan injected 6 days before surgery in combination with 10 J x cm(-2) 652 nm light. Dose limiting toxicity at the next higher dose was a systemic capillary leak syndrome leading to death in 2 of 3 patients treated at that dose. Other PDT-related toxicities included wound burns and skin photosensitivity. In all, 14 patients were treated at the MTD without significant complications. Foscan-mediated PDT can be safely combined with surgery at the established MTD. Unlike most other surgery-based multimodal treatments for mesothelioma, Foscan-mediated PDT affords the option, in selected patients, of accomplishing tumor debulking with a lung-sparing procedure rather than an extrapleural pneumonectomy. A phase II study is warranted.

  8. Therapeutic effects of atorvastatin and ezetimibe compared with double-dose atorvastatin in very elderly patients with acute coronary syndrome.

    PubMed

    Liu, Zhi; Hao, Hengjian; Yin, Chunlin; Chu, Yanyan; Li, Jing; Xu, Dong

    2017-06-20

    Objective Compared the effect of atorvastatin 10 mg combined ezetimibe 10 mg therapy with atorvastatin 20 mg on the long-term outcomes in very elderly patients with acute coronary syndrome.Methods A total of 230 octogenarian patients with acute coronary syndrome underwent coronary angiography were randomized to combined therapy group (atorvastatin 10 mg/d and ezetimibe 10 mg/d, n=114) or double-dose atorvastatin group (atorvastatin 20mg/d, n=116). The primary end point was one-year incidence of major adverse cardiovascular events (including cardiac death, spontaneous myocardial infarction, unplanned revascularization).Result At the end of one year, the percentage of patients with low-density lipoprotein cholesterol level decreased more than 30% or 50% were comparable between the two groups (93.5% vs. 90.1%, p= 0.36; 54.6% vs. 49.6%, p= 0.45). The rate of major adverse cardiovascular events in combined therapy group was similar with double-dose atorvastatin group (23.2% vs. 19.8%, p=0.55). In COX regression model, the risk of major adverse cardiovascular events in combined group isn't significantly higher than double-dose atorvastatin group (HR [95% CI] 1.12 [0.51 to 2.55], p = 0.74). The patients whose alanine aminotransferase increasing more than upper normal limit in combined group was lower than double-dose atorvastatin group (2.8% vs. 9.0%, p = 0.05).Conclusions For very elderly patients with acute coronary syndrome, atorvastatin combining ezetimibe induced similar long-term outcomes compared with double-dose atorvastatin but with less liver dysfunction.

  9. Cancer risk estimates from radiation therapy for heterotopic ossification prophylaxis after total hip arthroplasty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mazonakis, Michalis; Berris, Theoharris; Damilakis, John

    2013-10-15

    Purpose: Heterotopic ossification (HO) is a frequent complication following total hip arthroplasty. This study was conducted to calculate the radiation dose to organs-at-risk and estimate the probability of cancer induction from radiotherapy for HO prophylaxis.Methods: Hip irradiation for HO with a 6 MV photon beam was simulated with the aid of a Monte Carlo model. A realistic humanoid phantom representing an average adult patient was implemented in Monte Carlo environment for dosimetric calculations. The average out-of-field radiation dose to stomach, liver, lung, prostate, bladder, thyroid, breast, uterus, and ovary was calculated. The organ-equivalent-dose to colon, that was partly included withinmore » the treatment field, was also determined. Organ dose calculations were carried out using three different field sizes. The dependence of organ doses upon the block insertion into primary beam for shielding colon and prosthesis was investigated. The lifetime attributable risk for cancer development was estimated using organ, age, and gender-specific risk coefficients.Results: For a typical target dose of 7 Gy, organ doses varied from 1.0 to 741.1 mGy by the field dimensions and organ location relative to the field edge. Blocked field irradiations resulted in a dose range of 1.4–146.3 mGy. The most probable detriment from open field treatment of male patients was colon cancer with a high risk of 564.3 × 10{sup −5} to 837.4 × 10{sup −5} depending upon the organ dose magnitude and the patient's age. The corresponding colon cancer risk for female patients was (372.2–541.0) × 10{sup −5}. The probability of bladder cancer development was more than 113.7 × 10{sup −5} and 110.3 × 10{sup −5} for males and females, respectively. The cancer risk range to other individual organs was reduced to (0.003–68.5) × 10{sup −5}.Conclusions: The risk for cancer induction from radiation therapy for HO prophylaxis after total hip arthroplasty varies considerably by the treatment parameters, organ site in respect to treatment volume and patient's gender and age. The presented risk estimates may be useful in the follow-up studies of irradiated patients.« less

  10. Multileaf Collimator Tracking Improves Dose Delivery for Prostate Cancer Radiation Therapy: Results of the First Clinical Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colvill, Emma; Northern Sydney Cancer Centre, Royal North Shore Hospital, St. Leonards, NSW; Booth, Jeremy T.

    2015-08-01

    Purpose: To test the hypothesis that multileaf collimator (MLC) tracking improves the consistency between the planned and delivered dose compared with the dose without MLC tracking, in the setting of a prostate cancer volumetric modulated arc therapy trial. Methods and Materials: Multileaf collimator tracking was implemented for 15 patients in a prostate cancer radiation therapy trial; in total, 513 treatment fractions were delivered. During each treatment fraction, the prostate trajectory and treatment MLC positions were collected. These data were used as input for dose reconstruction (multiple isocenter shift method) to calculate the treated dose (with MLC tracking) and the dose thatmore » would have been delivered had MLC tracking not been applied (without MLC tracking). The percentage difference from planned for target and normal tissue dose-volume points were calculated. The hypothesis was tested for each dose-volume value via analysis of variance using the F test. Results: Of the 513 fractions delivered, 475 (93%) were suitable for analysis. The mean difference and standard deviation between the planned and treated MLC tracking doses and the planned and without-MLC tracking doses for all 475 fractions were, respectively, PTV D{sub 99%} −0.8% ± 1.1% versus −2.1% ± 2.7%; CTV D{sub 99%} −0.6% ± 0.8% versus −0.6% ± 1.1%; rectum V{sub 65%} 1.6% ± 7.9% versus −1.2% ± 18%; and bladder V{sub 65%} 0.5% ± 4.4% versus −0.0% ± 9.2% (P<.001 for all dose-volume results). Conclusion: This study shows that MLC tracking improves the consistency between the planned and delivered doses compared with the modeled doses without MLC tracking. The implications of this finding are potentially improved patient outcomes, as well as more reliable dose-volume data for radiobiological parameter determination.« less

  11. Phase I dose escalation study of capecitabine and erlotinib concurrent with radiation in locally advanced pancreatic cancer.

    PubMed

    Jiang, Yixing; Mackley, Heath B; Kimchi, Eric T; Zhu, Junjia; Gusani, Niraj; Kaifi, Jussuf; Staveley-O'Carroll, Kevin F; Belani, Chandra P

    2014-07-01

    Pancreatic cancer is one of the leading causes of cancer-related deaths worldwide. The median survival of locally advanced nonoperable disease is approximately 9 months. 5-FU-based chemoradiotherapy has been the standard treatment. However, the survival benefit of this approach is modest. To improve the efficacy of 5-FU-based chemoradiation therapy, we evaluated the safety and feasibility of the combination of capecitabine and erlotinib with radiotherapy in this group of patients. A traditional "3 + 3" dose escalation design was adopted in the study. A total of four dose levels were designed. For safety purpose, a minus I dose level (-I) was also planned. The -I level consisted of capecitabine 600 mg/m² and erlotinib 50 mg daily, and the remaining four dose levels were as follows: level I: capecitabine 600 mg/m² bid (twice daily); level II: 700 mg/m² bid; level III: 825 mg/m² bid; and level IV: 925 mg/m² bid. Erlotinib was administered at 100 mg daily at all dose levels. Erlotinib and capceitabine were given continuously Monday through Friday concurrent with radiotherapy (50.4 Gy in 28 fractions). A total of 18 patients were consented. Fifteen patients were enrolled and completed therapy. No dose-limiting toxicity was observed. The most frequent side effects were lymphopenia, nausea, vomiting, diarrhea, electrolyte imbalances, and skin rashes. The majority of the toxicities were grade 1 and 2. No objective response was observed. The median progression-free survival was 0.59 years (95 % CI 0.31-1.1), and the median overall survival was 1.1 years (95 % CI 0.62-1.59). The combination of capecitabine and erlotinib with radiotherapy in locally advanced pancreatic cancer is well tolerated and feasible at the dose level of capecitabine 925 mg/m² bid and erlotinib 100 mg daily.

  12. Randomized study of intensified anthracycline doses for induction and recombinant interleukin-2 for maintenance in patients with acute myeloid leukemia age 50 to 70 years: results of the ALFA-9801 study.

    PubMed

    Pautas, Cecile; Merabet, Fatiha; Thomas, Xavier; Raffoux, Emmanuel; Gardin, Claude; Corm, Selim; Bourhis, Jean-Henri; Reman, Oumedaly; Turlure, Pascal; Contentin, Nathalie; de Revel, Thierry; Rousselot, Philippe; Preudhomme, Claude; Bordessoule, Dominique; Fenaux, Pierre; Terré, Christine; Michallet, Mauricette; Dombret, Hervé; Chevret, Sylvie; Castaigne, Sylvie

    2010-02-10

    PURPOSE In patients with acute myeloid leukemia (AML), induction chemotherapy is based on standard doses of anthracyclines and cytarabine. High doses of cytarabine have been reported as being too toxic for patients older than age 50 years, but few studies have evaluated intensified doses of anthracyclines. PATIENTS AND METHODS In this randomized Acute Leukemia French Association 9801 (ALFA-9801) study, high doses of daunorubicin (DNR; 80 mg/m(2)/d x 3 days) or idarubicin (IDA4; 12 mg/m(2)/d x 4 days) were compared with standard doses of idarubicin (IDA3; 12 mg/m(2)/d x 3 days) for remission induction in patients age 50 to 70 years, with an event-free survival (EFS) end point. After two consolidation courses based on intermediate doses of cytarabine, patients in continuous remission were randomly assigned to receive or not receive maintenance therapy with recombinant interleukin-2 (rIL-2; 5 x 10(6) U/m(2) x 5 days each month) for a total duration of 12 months. A total of 468 patients entered the study (median age, 60 years). Results Overall complete remission rate was 77% with significant differences among the three randomization arms (83%, 78%, and 70% in the IDA3, IDA4, and DNR arms, respectively; P = .04). However, no significant differences were observed in relapse incidence, EFS, or overall survival among the three arms. In the 161 patients randomly assigned for maintenance therapy, no difference in outcome was observed between the rIL-2 and the no further treatment arms. CONCLUSION Neither intensification of anthracycline doses nor maintenance with rIL-2 showed a significant impact on AML course, at least as scheduled in this trial.

  13. Dosimetric feasibility of 4DCT-ventilation imaging guided proton therapy for locally advanced non-small-cell lung cancer.

    PubMed

    Huang, Qijie; Jabbour, Salma K; Xiao, Zhiyan; Yue, Ning; Wang, Xiao; Cao, Hongbin; Kuang, Yu; Zhang, Yin; Nie, Ke

    2018-04-25

    The principle aim of this study is to incorporate 4DCT ventilation imaging into functional treatment planning that preserves high-functioning lung with both double scattering and scanning beam techniques in proton therapy. Eight patients with locally advanced non-small-cell lung cancer were included in this study. Deformable image registration was performed for each patient on their planning 4DCTs and the resultant displacement vector field with Jacobian analysis was used to identify the high-, medium- and low-functional lung regions. Five plans were designed for each patient: a regular photon IMRT vs. anatomic proton plans without consideration of functional ventilation information using double scattering proton therapy (DSPT) and intensity modulated proton therapy (IMPT) vs. functional proton plans with avoidance of high-functional lung using both DSPT and IMPT. Dosimetric parameters were compared in terms of tumor coverage, plan heterogeneity, and avoidance of normal tissues. Our results showed that both DSPT and IMPT plans gave superior dose advantage to photon IMRTs in sparing low dose regions of the total lung in terms of V5 (volume receiving 5Gy). The functional DSPT only showed marginal benefit in sparing high-functioning lung in terms of V5 or V20 (volume receiving 20Gy) compared to anatomical plans. Yet, the functional planning in IMPT delivery, can further reduce the low dose in high-functioning lung without degrading the PTV dosimetric coverages, compared to anatomical proton planning. Although the doses to some critical organs might increase during functional planning, the necessary constraints were all met. Incorporating 4DCT ventilation imaging into functional proton therapy is feasible. The functional proton plans, in intensity modulated proton delivery, are effective to further preserve high-functioning lung regions without degrading the PTV coverage.

  14. A randomized comparative trial of two low-dose oral isotretinoin regimens in moderate to severe acne vulgaris

    PubMed Central

    Dhaked, Daulat Ram; Meena, Ram Singh; Maheshwari, Anshul; Agarwal, Uma Shankar; Purohit, Saroj

    2016-01-01

    Background: Oral isotretinoin is highly effective in all forms and grades of acne, even in lower dosages (<0.5 mg/kg/day). There is a paucity of comparative data on the various low-dose regimens of oral isotretinoin in the Indian literature. Objectives: To assess and compare the efficacy and tolerability of two low-dose oral isotretinoin treatment regimens (20 mg daily and 20 mg alternate days) in moderate to severe acne vulgaris. Materials and Methods: A total of 240 patients with moderate to severe acne vulgaris were selected and randomized into two groups and treated with a fixed dose of 20 mg of isotretinoin (Group A - daily and Group B - alternate days) for 24 weeks and followed up for 12 weeks post therapy. Results: A total of 234 patients completed the study. At the end of therapy, decrease in the total acne loads up to 98.99% (Group A) and 97.69% (Group B) was achieved from the baseline (P < 0.01), excellent response was observed in 98.3% (Group A) and 93.96% (Group B) patients (P = 0.166). In the severe acne, Group A performed significantly better than Group B until the end of 36 weeks. While in the moderate acne, significant difference in the response between both groups was observed only up to 12 weeks. No serious side effect was observed. Conclusion: Both isotretinoin regimens were well tolerated and found to be an effective treatment for moderate to severe acne vulgaris. However, in moderate acne 20 mg alternate day regimen may be preferred. A 20 mg daily regimen is a better choice for severe acne in terms of response. Limitation: Small sample size and short follow-up period. PMID:27730033

  15. Custom-made micro applicators for high-dose-rate brachytherapy treatment of chronic psoriasis.

    PubMed

    Buzurovic, Ivan M; O'Farrell, Desmond A; Bhagwat, Mandar S; Hansen, Jorgen L; Harris, Thomas C; Friesen, Scott; Cormack, Robert A; Devlin, Phillip M

    2017-06-01

    In this study, we present the treatment of the psoriatic nail beds of patients refractory to standard therapies using high-dose-rate (HDR) brachytherapy. The custom-made micro applicators (CMMA) were designed and constructed for radiation dose delivery to small curvy targets with complicated topology. The role of the HDR brachytherapy treatment was to stimulate the T cells for an increased immune response. The patient diagnosed with psoriatic nail beds refractory to standard therapies received monthly subunguinal injections that caused significant pain and discomfort in both hands. The clinical target was defined as the length from the fingertip to the distal interphalangeal joint. For the accurate and reproducible setup in the multi-fractional treatment delivery, the CMMAs were designed. Five needles were embedded into the dense plastic mesh and covered with 5 mm bolus material for each micro applicator. Five CMMAs were designed, resulting in the usage of 25 catheters in total. The prescription dose was planned to the depth of the anterior surface of the distal phalanx, allowing for the sparing of the surrounding tissue. The total number of the active dwell positions was 145 with step size of 5 mm. The total treatment time was 115 seconds with a 7.36 Ci activity of the 192 Ir source. The treatment resulted in good pain control. The patient did not require further injections to the nail bed. After this initial treatment, additional two patients with similar symptoms received HDR brachytherapy. The treatment outcome was favorable in all cases. The first HDR brachytherapy treatment of psoriasis of the nail bed is presented. The initial experience revealed that brachytherapy treatment was well-tolerated and resulted in adequate control of the disease. A larger cohort of patients will be required for additional conclusions related to the long-term clinical benefits.

  16. Ipsilateral kidney sparing in treatment of pancreatic malignancies using volumetric-modulated arc therapy avoidance sectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chan, Raymond W., E-mail: rwc3b@alumni.virginia.edu; Podgorsak, Matthew B.

    Recent research has shown treating pancreatic cancer with volumetric-modulated arc therapy (VMAT) to be superior to either intensity-modulated radiation therapy or 3-dimensional conformal radiotherapy (3D-CRT), with respect to reducing normal tissue toxicity, monitor units, and treatment time. Furthermore, using avoidance sectors with RapidArc planning can further reduce normal tissue dose while maintaining target conformity. This study looks at the methods in reducing dose to the ipsilateral kidney, in pancreatic head cases, while observing dose received by other critical organs using avoidance sectors. Overall, 10 patients were retrospectively analyzed. Each patient had preoperative/unresectable pancreatic tumor and were selected based on themore » location of the right kidney being situated within the traditional 3D-CRT treatment field. The target planning target volume (286.97 ± 85.17 cm{sup 3}) was prescribed to 50.4 Gy using avoidance sectors of 30°, 40°, and 50° and then compared with VMAT as well as 3D-CRT. Analysis of the data shows that the mean dose to the right kidney was reduced by 11.6%, 15.5%, and 21.9% for avoidance angles of 30°, 40°, and 50°, respectively, over VMAT. The mean dose to the total kidney also decreased by 6.5%, 8.5%, and 11.0% for the same increasing angles. Spinal cord maximum dose, however, increased as a function of angle by 3.7%, 4.8%, and 6.1% compared with VMAT. Employing avoidance sector angles as a complement to VMAT planning can significantly reduce high dose to the ipsilateral kidney while not greatly overdosing other critical organs.« less

  17. Treatment planning with intensity modulated particle therapy for multiple targets in stage IV non-small cell lung cancer

    NASA Astrophysics Data System (ADS)

    Anderle, Kristjan; Stroom, Joep; Vieira, Sandra; Pimentel, Nuno; Greco, Carlo; Durante, Marco; Graeff, Christian

    2018-01-01

    Intensity modulated particle therapy (IMPT) can produce highly conformal plans, but is limited in advanced lung cancer patients with multiple lesions due to motion and planning complexity. A 4D IMPT optimization including all motion states was expanded to include multiple targets, where each target (isocenter) is designated to specific field(s). Furthermore, to achieve stereotactic treatment planning objectives, target and OAR weights plus objective doses were automatically iteratively adapted. Finally, 4D doses were calculated for different motion scenarios. The results from our algorithm were compared to clinical stereotactic body radiation treatment (SBRT) plans. The study included eight patients with 24 lesions in total. Intended dose regimen for SBRT was 24 Gy in one fraction, but lower fractionated doses had to be delivered in three cases due to OAR constraints or failed plan quality assurance. The resulting IMPT treatment plans had no significant difference in target coverage compared to SBRT treatment plans. Average maximum point dose and dose to specific volume in OARs were on average 65% and 22% smaller with IMPT. IMPT could also deliver 24 Gy in one fraction in a patient where SBRT was limited due to the OAR vicinity. The developed algorithm shows the potential of IMPT in treatment of multiple moving targets in a complex geometry.

  18. SU-E-T-616: Comparison of Plan Dose Accuracy for Anterior Vs. Lateral Fields in Proton Therapy of Prostate Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moteabbed, M; Trofimov, A; Testa, M

    2014-06-01

    Purpose: With the anticipated introduction of in vivo range verification methods, the use of anterior fields for proton therapy of prostate cancer may become an attractive treatment option, and improve upon the dose distributions achievable with conventional lateral-opposed fields. This study aimed to evaluate and compare the planned dose accuracy for lateral versus anterior oblique field arrangements. Methods: Four patients with low/intermediate risk prostate cancer, participating in a clinical trial at our institution, were selected for this study. All patients were treated using lateral-opposed fields (LAT). The clinical target volume (CTV) received a total dose of 79.2 Gy in 44more » fractions. Anterior oblique research plans (ANT) were created using the clinical planning system, and featured beams with ±35-degree gantry angle, 1.2 cm aperture margins, 3-mm range compensator smearing and no range uncertainty margins. Monte Carlo (MC) simulations were performed for both beam arrangements using TOPAS. Dose volume histograms were analyzed and compared for planned and MC dose distributions. Differences between MC and planned DVH parameters were computed as a percentage of the total prescribed dose. Results: For all patients, CTV dose was systematically lower (∼2–2.5%) for MC than the plan. This discrepancy was slightly larger (∼0.5%) for LAT compared to ANT plans for all cases. Although the dose differences for bladder and anterior rectal wall remained within 0.7% for all LAT cases, they were slightly larger for ANT plans, especially for case 3 due to larger patient size and MC-plan range difference. The EUD difference for femoral heads was within 0.6% for both LAT and ANT cases. Conclusion: The dose calculated by the treatment planning system using pencil beam algorithm agrees with MC to within 2.5% and is comparable for lateral and anterior scenarios. The dose agreement in the anterior rectal wall is range- and hence, patient-dependent for ANT treatments.« less

  19. Randomized clinical trial of postoperative strontium-90 radiation therapy for pterygia: treatment using 30 Gy/3 fractions vs. 40 Gy/4 fractions.

    PubMed

    Nakamatsu, Kiyoshi; Nishimura, Yasumasa; Kanamori, Shuichi; Koike, Ryuta; Tachibana, Izumi; Nishikawa, Tatsuyuki; Shibata, Toru

    2011-07-01

    Postoperative adjuvant treatment with strontium-90 radiation therapy (RT) is a proven technique for reducing the recurrence of pterygium. This randomized trial was conducted to evaluate whether a total dose of 40 Gy provides a better local control rate than a total dose of 30 Gy for surgically resected pterygia. A single institutional randomized trial was conducted. Between 1999 and 2003, 74 pterygia in 71 patients were randomly allocated to 30 Gy/3 fractions/15 days (arm A) or to 40 Gy/4 fractions/22 days (arm B). Only primary pterygia for which RT could be started within 3 days of surgical resection were included. Postoperative RT was given by a strontium-90 eye applicator, and a dose of 10 Gy per fraction was delivered in weekly fractions (day 1, 8, 15, 22). Of the 74 pterygia treated, 73 in 70 patients were analyzed. Of the 73 pterygia, 41 were allocated to arm A, and the remaining 32 to arm B. The 2-year local control rates for arm A and arm B were 85% and 75%, respectively, without significant difference. No serious acute and late complications were noted in either arm. Our new standard fractionation for postoperative RT for pterygia is 30 Gy/3 fractions.

  20. Longitudinal analysis of the use of etanercept versus infliximab determined from medical chart audit.

    PubMed

    Abarca, Jacob; Malone, Daniel C; Armstrong, Edward P; Grizzle, Amy J; Cohen, Marc D

    2004-01-01

    To describe the dosing of etanercept and infliximab for the treatment of rheumatoid arthritis (RA). Adult patients with a diagnosis of RA who were treated with either etanercept or infliximab between 1999 and 2002 were selected from 16 rheumatology practices in the western and southeastern United States. Patients with a terminal illness or those receiving a tumor necrosis factor (TNF)-alpha inhibitor for an indication other than RA were excluded. Data were collected through a review of the patient medical records. Data collected on each patient included demographics, concurrent disease-modifying antirheumatic drug therapy, TNF-alpha inhibitor dose, frequency, duration of TNF-alpha inhibitor therapy, and discontinuation of TNF-alpha inhibitor therapy. A total of 244 patients were included in the evaluation (etanercept only [n=128; 52%], infliximab only [n=89; 36%], both [n=27; 11%]). The mean age of these patients was 55.1+/-13.3 years, 54.9+/-13.5 years, and 52.8+/-14.0 years, respectively; the mean duration of RA was 13.3 +/- 8.8 years, 13.4+/-8.0 years, and 14.0 +/- 9.9 years, respectively. Female patients constituted 70% of the sample. Health maintenance organization insurance was the most common form of medical insurance (45.8%), followed by Medicare (22.3%). The mean duration of follow-up for etanercept and infliximab treatment was 29.3+/-14.1 months and 14.8+/-6.9 months, respectively. Among patients who were still receiving therapy at the time of review, the mean initial and last etanercept doses were 25.0 mg versus 25.8 mg (P=0.16); the mean initial and last infliximab doses were 3.38 mg/kg versus 4.51 mg/kg (P<0.001). The dosing of etanercept and infliximab therapy was consistent with the approved labeling of both medications.

  1. A new approach to integrate GPU-based Monte Carlo simulation into inverse treatment plan optimization for proton therapy.

    PubMed

    Li, Yongbao; Tian, Zhen; Song, Ting; Wu, Zhaoxia; Liu, Yaqiang; Jiang, Steve; Jia, Xun

    2017-01-07

    Monte Carlo (MC)-based spot dose calculation is highly desired for inverse treatment planning in proton therapy because of its accuracy. Recent studies on biological optimization have also indicated the use of MC methods to compute relevant quantities of interest, e.g. linear energy transfer. Although GPU-based MC engines have been developed to address inverse optimization problems, their efficiency still needs to be improved. Also, the use of a large number of GPUs in MC calculation is not favorable for clinical applications. The previously proposed adaptive particle sampling (APS) method can improve the efficiency of MC-based inverse optimization by using the computationally expensive MC simulation more effectively. This method is more efficient than the conventional approach that performs spot dose calculation and optimization in two sequential steps. In this paper, we propose a computational library to perform MC-based spot dose calculation on GPU with the APS scheme. The implemented APS method performs a non-uniform sampling of the particles from pencil beam spots during the optimization process, favoring those from the high intensity spots. The library also conducts two computationally intensive matrix-vector operations frequently used when solving an optimization problem. This library design allows a streamlined integration of the MC-based spot dose calculation into an existing proton therapy inverse planning process. We tested the developed library in a typical inverse optimization system with four patient cases. The library achieved the targeted functions by supporting inverse planning in various proton therapy schemes, e.g. single field uniform dose, 3D intensity modulated proton therapy, and distal edge tracking. The efficiency was 41.6  ±  15.3% higher than the use of a GPU-based MC package in a conventional calculation scheme. The total computation time ranged between 2 and 50 min on a single GPU card depending on the problem size.

  2. A new approach to integrate GPU-based Monte Carlo simulation into inverse treatment plan optimization for proton therapy

    NASA Astrophysics Data System (ADS)

    Li, Yongbao; Tian, Zhen; Song, Ting; Wu, Zhaoxia; Liu, Yaqiang; Jiang, Steve; Jia, Xun

    2017-01-01

    Monte Carlo (MC)-based spot dose calculation is highly desired for inverse treatment planning in proton therapy because of its accuracy. Recent studies on biological optimization have also indicated the use of MC methods to compute relevant quantities of interest, e.g. linear energy transfer. Although GPU-based MC engines have been developed to address inverse optimization problems, their efficiency still needs to be improved. Also, the use of a large number of GPUs in MC calculation is not favorable for clinical applications. The previously proposed adaptive particle sampling (APS) method can improve the efficiency of MC-based inverse optimization by using the computationally expensive MC simulation more effectively. This method is more efficient than the conventional approach that performs spot dose calculation and optimization in two sequential steps. In this paper, we propose a computational library to perform MC-based spot dose calculation on GPU with the APS scheme. The implemented APS method performs a non-uniform sampling of the particles from pencil beam spots during the optimization process, favoring those from the high intensity spots. The library also conducts two computationally intensive matrix-vector operations frequently used when solving an optimization problem. This library design allows a streamlined integration of the MC-based spot dose calculation into an existing proton therapy inverse planning process. We tested the developed library in a typical inverse optimization system with four patient cases. The library achieved the targeted functions by supporting inverse planning in various proton therapy schemes, e.g. single field uniform dose, 3D intensity modulated proton therapy, and distal edge tracking. The efficiency was 41.6  ±  15.3% higher than the use of a GPU-based MC package in a conventional calculation scheme. The total computation time ranged between 2 and 50 min on a single GPU card depending on the problem size.

  3. A New Approach to Integrate GPU-based Monte Carlo Simulation into Inverse Treatment Plan Optimization for Proton Therapy

    PubMed Central

    Li, Yongbao; Tian, Zhen; Song, Ting; Wu, Zhaoxia; Liu, Yaqiang; Jiang, Steve; Jia, Xun

    2016-01-01

    Monte Carlo (MC)-based spot dose calculation is highly desired for inverse treatment planning in proton therapy because of its accuracy. Recent studies on biological optimization have also indicated the use of MC methods to compute relevant quantities of interest, e.g. linear energy transfer. Although GPU-based MC engines have been developed to address inverse optimization problems, their efficiency still needs to be improved. Also, the use of a large number of GPUs in MC calculation is not favorable for clinical applications. The previously proposed adaptive particle sampling (APS) method can improve the efficiency of MC-based inverse optimization by using the computationally expensive MC simulation more effectively. This method is more efficient than the conventional approach that performs spot dose calculation and optimization in two sequential steps. In this paper, we propose a computational library to perform MC-based spot dose calculation on GPU with the APS scheme. The implemented APS method performs a non-uniform sampling of the particles from pencil beam spots during the optimization process, favoring those from the high intensity spots. The library also conducts two computationally intensive matrix-vector operations frequently used when solving an optimization problem. This library design allows a streamlined integration of the MC-based spot dose calculation into an existing proton therapy inverse planning process. We tested the developed library in a typical inverse optimization system with four patient cases. The library achieved the targeted functions by supporting inverse planning in various proton therapy schemes, e.g. single field uniform dose, 3D intensity modulated proton therapy, and distal edge tracking. The efficiency was 41.6±15.3% higher than the use of a GPU-based MC package in a conventional calculation scheme. The total computation time ranged between 2 and 50 min on a single GPU card depending on the problem size. PMID:27991456

  4. Agalsidase Benefits Renal Histology in Young Patients with Fabry Disease

    PubMed Central

    Bostad, Leif; Larsen, Kristin Kampevold; Hirth, Asle; Vikse, Bjørn Egil; Houge, Gunnar; Svarstad, Einar

    2012-01-01

    The effect of early-onset enzyme replacement therapy on renal morphologic features in Fabry disease is largely unknown. Here, we evaluated the effect of 5 years of treatment with agalsidase alfa or agalsidase beta in 12 consecutive patients age 7–33 years (median age, 16.5 years). We performed renal biopsies at baseline and after 5 years of enzyme replacement therapy; 7 patients had additional biopsies after 1 and 3 years. After a median of 65 months, biopsy findings from all patients showed total clearance of glomerular endothelial and mesangial cell inclusions, and findings from 2 patients showed complete clearance of inclusions from epithelial cells of the distal tubule. The 4 patients who received the highest dose of agalsidase exhibited substantial clearance of podocyte inclusions, and the youngest patient had nearly complete clearance of these inclusions. Linear regression analysis showed a highly significant correlation between podocyte globotriaocylceramide clearance and cumulative agalsidase dose (r=0.804; P=0.002). Microalbuminuria normalized in five patients. In summary, long-term enzyme replacement therapy in young patients can result in complete globotriaocylceramide clearance of mesangial and glomerular endothelial cells across all dosage regimens, and clearance of podocyte inclusions is dose-dependent. PMID:23274955

  5. Intra-arterial Methylprednisolone Infusion in Treatment-Resistant Graft-Versus-Host Disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weintraub, Joshua L., E-mail: Joshua.Weintraub@mssm.edu; Belanger, Adam R.; Sung, Chris C.

    Acute graft-versus-host disease (GVHD) is a potentially fatal complication following allogeneic hematopoietic stem cell transplant. Standard primary therapy for acute GVHD includes systemic steroids, often in combination with other agents. Unfortunately, primary treatment failure is common and carries a high mortality. There is no generally accepted secondary therapy for acute GVHD. Although few data on localized therapy for GVHD have been published, intra-arterial injection of high-dose corticosteroids may be a viable option. We treated 11 patients with steroid-resistant GVHD using a single administration of intra-arterial high-dose methylprednisolone. Three patients (27%) died periprocedurally. Four patients (36%) had a partial response tomore » intra-arterial treatment and were discharged on total parenteral nutrition and oral medication. Four patients (36%) had a complete response and were discharged on oral diet and oral medication. No immediate treatment or procedure-related complications were noted. Twenty-seven percent of patients survived long-term. Our preliminary results suggest that regional intra-arterial treatment of steroid-resistant GVHD is a safe and potentially viable secondary therapy in primary treatment-resistant GVHD.« less

  6. eHealth: individualization of mesalazine treatment through a self-managed web-based solution in mild-to-moderate ulcerative colitis.

    PubMed

    Pedersen, Natalia; Thielsen, Peter; Martinsen, Lars; Bennedsen, Mette; Haaber, Anne; Langholz, Ebbe; Végh, Zsuzsanna; Duricova, Dana; Jess, Tine; Bell, Sally; Burisch, Johan; Munkholm, Pia

    2014-12-01

    To individualize treatment with mesalazine for ulcerative colitis relapses through a self-managed, web-based solution to optimize the short-term disease course. Prospective, open-label, web-guided study with 3 months mesalazine therapy among patients with mild-to-moderate ulcerative colitis. Once a week, patients completed the simple clinical colitis activity index (SCCAI) and registered fecal calprotectin (FC) on the web application: www.meza.constant-care.dk. SCCAI and FC were summed and resulted in a total inflammatory burden score (TIBS). Deep remission was defined as SCCAI ≤1; FC = 0, and TIBS ≤1. A total of 95 patients (62% females; median age 45 yr) were included in the study and allocated 4.8 g mesalazine per day. Of these, 82 (86%) patients were adherent to web therapy, completing 3 months of web-guided mesalazine therapy. Of the 82 adherent patients, 72 (88%) continued mesalazine and 10 (12%) needed rescue therapy. From weeks 0 to 12, patients had experienced a significant reduction in mean SCCAI (4.6 versus 1.6, P < 0.001), mean FC (437 versus 195, P < 0.001), and mean TIBS (6.7 versus 2.4, P < 0.001). Based on TIBS values (≤1), the dose of mesalazine was reduced to 2.4 g in 25% of patients at week 3 in 50% of subjects at week 5 and in 88% of patients at week 12. Web-guided therapy with mesalazine in mild-to-moderate ulcerative colitis helps to individualize the dose and improve adherence to therapy. The study confirms mesalazine efficacy in mild-to-moderate UC, significantly improving TIBS values in majority of the patients.

  7. [The clinical effect of combination therapy for oral cancer with S-1, superselective intra-arterial chemotherapy, and radiation therapy].

    PubMed

    Yamamoto, Chika; Yoshikawa, Hiromasa; Fukumoto, Shunsuke; Higuchi, Takashi; Yoshida, Masanori; Horinouchi, Yasufumi; Uehara, Satoru; Yasumori, Koutarou

    2011-12-01

    Combination therapy with S-1, superselective intra-arterial infusion of CBDCA and radiation therapy has been used to treat patients with oral cancer since 2005. In this study, the histopathological effects and toxicities following concurrent chemoradiotherapy were examined. The subjects consisted of 15 patients (10 men and 5 women) who were treated with S-1 (60-80 mg/day, 4 weeks), superselective intra-arterial infusion of CBDCA (300 mg/body) and radiation therapy (total dose 30-36 Gy) in our department from 2005 to 2009. Nine patients, showed T2 disease, 3 showed T3 disease, and another 3 showed T4 diseases. The primary cancer sites were the tongue (6 cases), buccal mucosa (4 cases), mandible gingival (3 cases), maxillary gingiva (1 case), and the floor of the mouth (1 case). The histopathological effects were evaluated according to Oboshi-Shimosato classification. Grade IV was shown in 10 cases (66. 7%), grade III in 1 case (6. 7%), II bin 3 cases (20. 0%), and II a in 1 case (6. 7%). All patients completed the treatment. The pathological response of the resected tumor was grade IIbor higher in 14 cases (93. 3%). While good histological effects were noted, there was one patient for whom viable tumor cells remained in the central part of the tumor. The present study indicates that further investigation is needed to determine the best dosing and dosing schedule.

  8. Risk Factors Associated With Symptomatic Radiation Pneumonitis After Stereotactic Body Radiation Therapy for Stage I Non-Small Cell Lung Cancer.

    PubMed

    Shi, Shiming; Zeng, Zhaochong; Ye, Luxi; Huang, Yan; He, Jian

    2017-06-01

    Radiation pneumonitis is the most frequent acute pulmonary toxicity following stereotactic body radiation therapy for lung cancer. Here, we investigate clinical and dosimetric factors associated with symptomatic radiation pneumonitis in patients with stage I non-small cell lung cancer treated with stereotactic body radiation therapy. A total of 67 patients with stage I non-small cell lung cancer who received stereotactic body radiation therapy at our institution were enrolled, and their clinicopathological parameters and dosimetric parameters were recorded and analyzed. The median follow-up period was 26.4 months (range: 7-48 months). In univariate analysis, tumor size ( P = .041), mean lung dose ( P = .028), V2.5 ( P = .024), V5 ( P = .014), V10 ( P = .004), V20 ( P = .024), V30 ( P = .020), V40 ( P = .040), and V50 ( P = 0.040) were associated with symptomatic radiation pneumonitis. In multivariable logistic regression analysis, V10 ( P = .049) was significantly associated with symptomatic radiation pneumonitis. In conclusion, this study found that tumor size, mean lung dose, and V2.5 to V50 were risk factors markedly associated with symptomatic radiation pneumonitis. Our data suggested that lung V10 was the most significant factor, and optimizing lung V10 may reduce the risk of symptomatic radiation pneumonitis. For both central and peripheral stage I lung cancer, rate of radiation pneumonitis ≥grade 2 was low after stereotactic body radiation therapy with appropriate fraction dose.

  9. TU-EF-304-12: Proton Radiation Therapy for Left-Sided Breast Cancer: LET and RBE Considerations for Cardiac Toxicity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giantsoudi, D; Jee, K; MacDonald, S

    Purpose: Increased risk of coronary artery disease has been documented for patients treated with radiation for left-sided breast cancer. Proton therapy (PRT) has been shown to significantly decrease cardiac irradiation, however variations in relative biological effectiveness (RBE) have been ignored so far. In this study we evaluate the impact of accounting for RBE variations on sensitive structures located within high linear energy transfer (LET) areas (distal end) of the proton treatment fields, for this treatment site. Methods: Three patients treated in our institution with PRT for left-sided breast cancer were selected. All patients underwent reconstructive surgery after mastectomy and treatedmore » to a total dose of 50.4Gy with beam(s) vertical to the chest wall. Dose and LET distributions were calculated using Monte Carlo (MC-TOPAS - TOol for PArticle Simulation). The LET-based, variable-RBE-weighted dose was compared to the analytical calculation algorithm (ACA) and MC dose distributions for a constant RBE of 1.1, based on volume histograms and mean values for the target, heart and left anterior descending coronary artery (LAD). Results: Assuming a constant RBE and compared to the ACA dose, MC predicted lower mean target and heart doses by 0.5% to 2.7% of the prescription dose. For variable RBE, plan evaluation showed increased mean target dose by up to 5%. Mean variable-RBE-weighted doses for the LAD ranged from 2.7 to 5.9Gy(RBE) among patients increased by 41%–64.2% compared to constant RBE ACA calculation (absolute dose: 1.7–3.9Gy(RBE)). Smaller increase in mean heart doses was noticed. Conclusion: ACA overestimates the target mean dose by up to 2.7%. However, disregarding variations in RBE may lead to significant underestimation of the dose to sensitive structures at the distal end of the proton treatment field and could thus impact outcome modeling for cardiac toxicities after proton therapy. These results are subject to RBE model and parameter uncertainties.« less

  10. Clinical applications of advanced rotational radiation therapy

    NASA Astrophysics Data System (ADS)

    Nalichowski, Adrian

    Purpose: With a fast adoption of emerging technologies, it is critical to fully test and understand its limits and capabilities. In this work we investigate new graphic processing unit (GPU) based treatment planning algorithm and its applications in helical tomotherapy dose delivery. We explore the limits of the system by applying it to challenging clinical cases of total marrow irradiation (TMI) and stereotactic radiosurgery (SRS). We also analyze the feasibility of alternative fractionation schemes for total body irradiation (TBI) and TMI based on reported historical data on lung dose and interstitial pneumonitis (IP) incidence rates. Methods and Materials: An anthropomorphic phantom was used to create TMI plans using the new GPU based treatment planning system and the existing CPU cluster based system. Optimization parameters were selected based on clinically used values for field width, modulation factor and pitch. Treatment plans were also created on Eclipse treatment planning system (Varian Medical Systems Inc, Palo Alto, CA) using volumetric modulated arc therapy (VMAT) for dose delivery on IX treatment unit. A retrospective review was performed of 42 publications that reported IP rates along with lung dose, fractionation regimen, dose rate and chemotherapy. The analysis consisted of nearly thirty two hundred patients and 34 unique radiation regimens. Multivariate logistic regression was performed to determine parameters associated with IP and establish does response function. Results: The results showed very good dosimetric agreement between the GPU and CPU calculated plans. The results from SBRT study show that GPU planning system can maintain 90% target coverage while meeting all the constraints of RTOG 0631 protocol. Beam on time for Tomotherapy and flattening filter free RapidArc was much faster than for Vero or Cyberknife. Retrospective data analysis showed that lung dose and Cyclophosphomide (Cy) are both predictors of IP in TBI/TMI treatments. The dose rate was not found to be an independent risk factor for IP. The model failed to establish accurate dose response function, but the discrete data indicated a radiation dose threshold of 7.6Gy (EQD2_repair) and 120 mg/kg of Cy below which no IP cases were reported. Conclusion: The TomoTherapy GPU based dose engine is capable of calculating TMI treatment plans with plan quality nearly identical to plans calculated using the traditional CPU/cluster based system, while significantly reducing the time required for optimization and dose calculation. The new system was able to achieve more uniform dose distribution throughout the target volume and steeper dose fall off, resulting in superior OAR sparing when compared to Eclipse treatment planning system for VMAT delivery. The machine optimization parameters tested for TMI cases provide a comprehensive overview of the capabilities of the treatment planning station and associated helical delivery system. The new system also proved to be dosimetrically compatible with other leading modalities for treatments of small and complicated target volumes and was even superior when treatment delivery times were compared. These finding demonstrate that the advanced treatment planning and delivery system from TomoTherapy is well suitable for treatments of complicated cases such as TMI and SRS and it's often dosimetrically and/or logistically superior to other modalities. The new planning system can easily meet the constraint of threshold lung dose established in this study. The results presented here on the capabilities of Tomotherapy and on the identified lung dose threshold provide an opportunity to explore alternative fractionation schemes without sacrificing target coverage or lung toxicity. (Abstract shortened by ProQuest.).

  11. A simpler method for total scalp irradiation: the multijaw-size concave arc technique.

    PubMed

    Inoue, Minoru; Konno, Masahiro; Ogawa, Hirofumi; Harada, Hideyuki; Asakura, Hirofumi; Fuji, Hiroshi; Murayama, Shigeyuki; Nishimura, Tetsuo

    2014-07-08

    The lateral electron-photon technique (LEPT) and intensity-modulated radiation therapy (IMRT) are commonly used for total scalp irradiation. However, the treatment planning and irradiation are laborious and time-consuming. We herein present the multijaw-size concave arc technique (MCAT) as a total scalp irradiation method that overcomes these problems. CT datasets for eight patients previously treated for angiosarcoma of the scalp were replanned using MCAT, LEPT, and IMRT. The MCAT was designed with a dynamic conformal arc for the total scalp, with a multileaf collimator to shield the brain. Two additional conformal arcs with a decreased upper-jaw position of the first dynamic conformal arc were used to reduce the cranial hotspots. The prescribed dose was 40 Gy (2 Gy/fraction) to 95% of the planning target volume (PTV, defined as the total scalp plus a 4 mm margin). MCAT was compared with LEPT and IMRT with respect to the PTV dose homogeneity (D5%-95%), underdosage (V < 90%), overdosage (V > 110%), doses to the brain, and the delivery time and monitor units (MUs) for single irradiation. We were able to formulate treatment plans for all three techniques that could deliver the prescription dose in all patients. MCAT was significantly superior to LEPT with respect to PTV dose homogeneity, overdosage, and underdosage, although MCAT was inferior to IMRT with respect to dose homogeneity and overdosage. The mean brain dose and high-dosage volume of all three techniques were low, but IMRT provided larger volume to the brain than did the other two techniques in the low dosage region. In MCAT, the mean delivery time could be reduced by approximately half or more, and the mean MUs could be reduced by at least 100 compared to the other two techniques. MCAT can achieve total scalp irradiation with substantially fewer MUs and a shorter delivery time than LEPT and IMRT.

  12. A simpler method for total scalp irradiation: the multijaw‐size concave arc technique

    PubMed Central

    Konno, Masahiro; Ogawa, Hirofumi; Harada, Hideyuki; Asakura, Hirofumi; Fuji, Hiroshi; Murayama, Shigeyuki; Nishimura, Tetsuo

    2014-01-01

    The lateral electron‐photon technique (LEPT) and intensity‐modulated radiation therapy (IMRT) are commonly used for total scalp irradiation. However, the treatment planning and irradiation are laborious and time‐consuming. We herein present the multijaw‐size concave arc technique (MCAT) as a total scalp irradiation method that overcomes these problems. CT datasets for eight patients previously treated for angiosarcoma of the scalp were replanned using MCAT, LEPT, and IMRT. The MCAT was designed with a dynamic conformal arc for the total scalp, with a multileaf collimator to shield the brain. Two additional conformal arcs with a decreased upper‐jaw position of the first dynamic conformal arc were used to reduce the cranial hotspots. The prescribed dose was 40 Gy (2 Gy/fraction) to 95% of the planning target volume (PTV, defined as the total scalp plus a 4 mm margin). MCAT was compared with LEPT and IMRT with respect to the PTV dose homogeneity (D5%–95%), underdosage (V < 90%), overdosage (V > 110%), doses to the brain, and the delivery time and monitor units (MUs) for single irradiation. We were able to formulate treatment plans for all three techniques that could deliver the prescription dose in all patients. MCAT was significantly superior to LEPT with respect to PTV dose homogeneity, overdosage, and underdosage, although MCAT was inferior to IMRT with respect to dose homogeneity and overdosage. The mean brain dose and high‐dosage volume of all three techniques were low, but IMRT provided larger volume to the brain than did the other two techniques in the low dosage region. In MCAT, the mean delivery time could be reduced by approximately half or more, and the mean MUs could be reduced by at least 100 compared to the other two techniques. MCAT can achieve total scalp irradiation with substantially fewer MUs and a shorter delivery time than LEPT and IMRT. PACS number: 87.55.D‐ PMID:25207405

  13. Preliminary analysis for integration of spot-scanning proton beam therapy and real-time imaging and gating.

    PubMed

    Shimizu, S; Matsuura, T; Umezawa, M; Hiramoto, K; Miyamoto, N; Umegaki, K; Shirato, H

    2014-07-01

    Spot-scanning proton beam therapy (PBT) can create good dose distribution for static targets. However, there exists larger uncertainty for tumors that move due to respiration, bowel gas or other internal circumstances within the patients. We have developed a real-time tumor-tracking radiation therapy (RTRT) system that uses an X-ray linear accelerator gated to the motion of internal fiducial markers introduced in the late 1990s. Relying on more than 10 years of clinical experience and big log data, we established a real-time image gated proton beam therapy system dedicated to spot scanning. Using log data and clinical outcomes derived from the clinical usage of the RTRT system since 1999, we have established a library to be used for in-house simulation for tumor targeting and evaluation. Factors considered to be the dominant causes of the interplay effects related to the spot scanning dedicated proton therapy system are listed and discussed. Total facility design, synchrotron operation cycle, and gating windows were listed as the important factors causing the interplay effects contributing to the irradiation time and motion-induced dose error. Fiducial markers that we have developed and used for the RTRT in X-ray therapy were suggested to have the capacity to improve dose distribution. Accumulated internal motion data in the RTRT system enable us to improve the operation and function of a Spot-scanning proton beam therapy (SSPT) system. A real-time-image gated SSPT system can increase accuracy for treating moving tumors. The system will start clinical service in early 2014. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  14. THE TREATMENT OF CHILDRENS' HEMANGIOMA AND NEVUS FLAMMEUS WITH Sr$sup 90$ AND Y$sup 9$$sup 0$ (in German)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lossl, H.; Jakob, A.

    The authors report the excellent results obtained in the radiotherapy of the hemangioma of the child and of the nevus flammeus by means of strontium-90 and yttrium-90. The method is preferred to others as it reduces the charge of rays on the growing skeleton of the child ami on the gonads. In case of smaller lesions the application of strontium-90 (total dose 3000 to 5000 rep) and surface irradiation by means of yttrium-90 foils (total dose 3000 to 4000 rep) produce good results. The single dose should be around 1OOO rep. The dosage has to be fixed according to themore » erythema which appears with medium intensity. To judge from the gathered experiences the results of this therapy are equivalent to those of radium treatment or Chaoul's close irradiation. (auth)« less

  15. Potential for intensity-modulated radiation therapy to permit dose escalation for canine nasal cancer.

    PubMed

    Vaudaux, Catherine; Schneider, Uwe; Kaser-Hotz, Barbara

    2007-01-01

    We evaluated the impact of inverse planned intensity-modulated radiation therapy (IMRT) on the dose-volume histograms (DVHs) and on the normal tissue complication probabilities (NTCPs) of brain and eyes in dogs with nasal tumors. Nine dogs with large, caudally located nasal tumors were planned using conventional techniques and inverse planned IMRT for a total prescribed dose of 52.5 Gy in 3.5 Gy fractions. The equivalent uniform dose for brain and eyes was calculated to estimate the normal tissue complication probability (NTCP) of these organs. The NTCP values as well as the DVHs were used to compare the treatment plans. The dose distribution in IMRT plans was more conformal than in conventional plans. The average dose delivered to one-third of the brain was 10 Gy lower with the IMRT plan compared with conventional planning. The mean partial brain volume receiving 43.6 Gy or more was reduced by 25.6% with IMRT. As a consequence, the NTCPs were also significantly lower in the IMRT plans. The mean NTCP of brain was two times lower and at least one eye could be saved in all patients planed with IMRT. Another possibility with IMRT is dose escalation in the target to improve tumor control while keeping the NTCPs at the same level as for conventional planning. Veterinary

  16. Improvement of dose calculation in radiation therapy due to metal artifact correction using the augmented likelihood image reconstruction.

    PubMed

    Ziemann, Christian; Stille, Maik; Cremers, Florian; Buzug, Thorsten M; Rades, Dirk

    2018-04-17

    Metal artifacts caused by high-density implants lead to incorrectly reconstructed Hounsfield units in computed tomography images. This can result in a loss of accuracy in dose calculation in radiation therapy. This study investigates the potential of the metal artifact reduction algorithms, Augmented Likelihood Image Reconstruction and linear interpolation, in improving dose calculation in the presence of metal artifacts. In order to simulate a pelvis with a double-sided total endoprosthesis, a polymethylmethacrylate phantom was equipped with two steel bars. Artifacts were reduced by applying the Augmented Likelihood Image Reconstruction, a linear interpolation, and a manual correction approach. Using the treatment planning system Eclipse™, identical planning target volumes for an idealized prostate as well as structures for bladder and rectum were defined in corrected and noncorrected images. Volumetric modulated arc therapy plans have been created with double arc rotations with and without avoidance sectors that mask out the prosthesis. The irradiation plans were analyzed for variations in the dose distribution and their homogeneity. Dosimetric measurements were performed using isocentric positioned ionization chambers. Irradiation plans based on images containing artifacts lead to a dose error in the isocenter of up to 8.4%. Corrections with the Augmented Likelihood Image Reconstruction reduce this dose error to 2.7%, corrections with linear interpolation to 3.2%, and manual artifact correction to 4.1%. When applying artifact correction, the dose homogeneity was slightly improved for all investigated methods. Furthermore, the calculated mean doses are higher for rectum and bladder if avoidance sectors are applied. Streaking artifacts cause an imprecise dose calculation within irradiation plans. Using a metal artifact correction algorithm, the planning accuracy can be significantly improved. Best results were accomplished using the Augmented Likelihood Image Reconstruction algorithm. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  17. Evaluation of image-guided helical tomotherapy for the retreatment of spinal metastasis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mahan, Stephen L.; Ramsey, Chester R.; Scaperoth, Daniel D.

    Introduction: Patients with vertebral metastasis that receive radiation therapy are typically treated to the spinal cord tolerance dose. As such, it is difficult to successfully deliver a second course of radiation therapy for patients with overlapping treatment volumes. In this study, an image-guided helical tomotherapy system was evaluated for the retreatment of previously irradiated vertebral metastasis. Methods and Materials: Helical tomotherapy dose gradients and maximum cord doses were measured in a cylindrical phantom for geometric test cases with separations between the planning target volume (PTV) and the spinal cord organ at risk (OAR) of 2 mm, 4 mm, 6 mm,more » 8 mm, and 10 mm. Megavoltage computed tomography (CT) images were examined for their ability to localize spinal anatomy for positioning purposes by repeat imaging of the cervical spine in an anthropomorphic phantom. In addition to the phantom studies, 8 patients with cord compressions that had received previous radiation therapy were retreated to a mean dose of 28 Gy using conventional fractionation. Results and Discussion: Megavoltage CT images were capable of positioning an anthropomorphic phantom to within {+-}1.2 mm (2{sigma}) superior-inferiorly and within {+-}0.6 mm (2{sigma}) anterior-posteriorly and laterally. Dose gradients of 10% per mm were measured in phantom while PTV uniformity indices of less than 11% were maintained. The calculated maximum cord dose was 25% of the prescribed dose for a 10-mm PTV-to-OAR separation and 71% of the prescribed dose for a PTV-to-OAR separation of 2 mm. Eight patients total have been treated without radiation-induced myelopathy or any other adverse effects from treatment. Conclusions: A technique has been evaluated for the retreatment of vertebral metastasis using image-guided helical tomotherapy. Phantom and patient studies indicated that a tomotherapy system is capable of delivering dose gradients of 10% per mm and positioning the patient within 1.2 mm without the use of special stereotactic immobilization.« less

  18. Radiation-induced second cancers: the impact of 3D-CRT and IMRT

    NASA Technical Reports Server (NTRS)

    Hall, Eric J.; Wuu, Cheng-Shie

    2003-01-01

    Information concerning radiation-induced malignancies comes from the A-bomb survivors and from medically exposed individuals, including second cancers in radiation therapy patients. The A-bomb survivors show an excess incidence of carcinomas in tissues such as the gastrointestinal tract, breast, thyroid, and bladder, which is linear with dose up to about 2.5 Sv. There is great uncertainty concerning the dose-response relationship for radiation-induced carcinogenesis at higher doses. Some animal and human data suggest a decrease at higher doses, usually attributed to cell killing; other data suggest a plateau in dose. Radiotherapy patients also show an excess incidence of carcinomas, often in sites remote from the treatment fields; in addition there is an excess incidence of sarcomas in the heavily irradiated in-field tissues. The transition from conventional radiotherapy to three-dimensional conformal radiation therapy (3D-CRT) involves a reduction in the volume of normal tissues receiving a high dose, with an increase in dose to the target volume that includes the tumor and a limited amount of normal tissue. One might expect a decrease in the number of sarcomas induced and also (less certain) a small decrease in the number of carcinomas. All around, a good thing. By contrast, the move from 3D-CRT to intensity-modulated radiation therapy (IMRT) involves more fields, and the dose-volume histograms show that, as a consequence, a larger volume of normal tissue is exposed to lower doses. In addition, the number of monitor units is increased by a factor of 2 to 3, increasing the total body exposure, due to leakage radiation. Both factors will tend to increase the risk of second cancers. Altogether, IMRT is likely to almost double the incidence of second malignancies compared with conventional radiotherapy from about 1% to 1.75% for patients surviving 10 years. The numbers may be larger for longer survival (or for younger patients), but the ratio should remain the same.

  19. Focal Radiation Therapy Dose Escalation Improves Overall Survival in Locally Advanced Pancreatic Cancer Patients Receiving Induction Chemotherapy and Consolidative Chemoradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krishnan, Sunil, E-mail: skrishnan@mdanderson.org; Chadha, Awalpreet S.; Suh, Yelin

    2016-03-15

    Purpose: To review outcomes of locally advanced pancreatic cancer (LAPC) patients treated with dose-escalated intensity modulated radiation therapy (IMRT) with curative intent. Methods and Materials: A total of 200 patients with LAPC were treated with induction chemotherapy followed by chemoradiation between 2006 and 2014. Of these, 47 (24%) having tumors >1 cm from the luminal organs were selected for dose-escalated IMRT (biologically effective dose [BED] >70 Gy) using a simultaneous integrated boost technique, inspiration breath hold, and computed tomographic image guidance. Fractionation was optimized for coverage of gross tumor and luminal organ sparing. A 2- to 5-mm margin around the gross tumor volume wasmore » treated using a simultaneous integrated boost with a microscopic dose. Overall survival (OS), recurrence-free survival (RFS), local-regional and distant RFS, and time to local-regional and distant recurrence, calculated from start of chemoradiation, were the outcomes of interest. Results: Median radiation dose was 50.4 Gy (BED = 59.47 Gy) with a concurrent capecitabine-based (86%) regimen. Patients who received BED >70 Gy had a superior OS (17.8 vs 15.0 months, P=.03), which was preserved throughout the follow-up period, with estimated OS rates at 2 years of 36% versus 19% and at 3 years of 31% versus 9% along with improved local-regional RFS (10.2 vs 6.2 months, P=.05) as compared with those receiving BED ≤70 Gy. Degree of gross tumor volume coverage did not seem to affect outcomes. No additional toxicity was observed in the high-dose group. Higher dose (BED) was the only predictor of improved OS on multivariate analysis. Conclusion: Radiation dose escalation during consolidative chemoradiation therapy after induction chemotherapy for LAPC patients improves OS and local-regional RFS.« less

  20. Risk of Radiation Retinopathy in Patients With Orbital and Ocular Lymphoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaushik, Megha; Pulido, Jose S.; Schild, Steven E.

    2012-12-01

    Purpose: Radiation retinopathy is a potential long-term complication of radiation therapy to the orbit. The risk of developing this adverse effect is dose dependent; however, the threshold is unclear. The aim of this study was to identify the risk of developing radiation retinopathy at increasing radiation doses. Methods and Materials: A 40-year retrospective review was performed of patients who received external beam radiation therapy for ocular/orbital non-Hodgkin lymphoma (NHL). Results: Sixty-seven patients who had at least one ophthalmic follow-up examination were included in this study. Most patients (52%) were diagnosed with NHL involving the orbit. Patients received external beam radiationmore » therapy at doses between 1886 and 5400 cGy (mean, 3033 {+-} 782 cGy). Radiation retinopathy developed in 12% of patients, and the median time to diagnosis was 27 months (range, 15-241months). The mean prescribed radiation dose in patients with retinopathy was 3309 {+-} 585 cGy, and the estimated retinal dose (derived by reviewing the dosimetry) was 3087 {+-} 1030 cGy. The incidence of retinopathy increased with dose. The average prescribed daily fractionated dose was higher in patients who developed retinopathy than in patients who did not (mean, 202 cGy vs 180 cGy, respectively; P = .04). More patients with radiation retinopathy had comorbid diabetes mellitus type 2 than patients without retinopathy (P = .015). In our study, the mean visual acuity of the eyes that received radiation was worse than that of the eyes that did not (P = .027). Other postradiotherapy ocular findings included keratitis (6%), dry eyes (39%), and cataract (33%). Conclusions: Radiation retinopathy, a known complication of radiotherapy for orbital tumors, relates to vascular comorbidities and dose. Higher total doses and larger daily fractions (>180 cGy) appear to be related to higher rates of retinopathy. Future larger studies are required to identify a statistically significant threshold for the development of retinopathy.« less

  1. [Endoprosthesis Infections - Guidelines for Antibiotic Therapy Common Guidelines of the Czech Society for Orthopaedics and Traumatology and the Society for Infectious Diseases of the Czech Medical Association of J. E. Purkyně].

    PubMed

    Musil, D; Balejová, M; Horníková, M; Chrdle, A; Mallátová, N; Nyč, O; Chmelík, V; Gallo, J; Jahoda, D; Stehlík, J

    2017-01-01

    PURPOSE OF THE STUDY This study aims to articulate regional guidelines for curative and suppressive antibiotic therapy of total joint replacement infections. MATERIAL AND METHODS When developing the standard, used as source materials were the published foreign guidelines for antibiotic therapy of prosthetic joint infections, the analysis of resistance of bacterial strains conducted in the Hospital in České Budějovice, a.s. and the assessment of strain resistance for the Czech Republic published by the European Antimicrobial Resistance Surveillance Network (EARS-Net). Considered was also the availability of individual antibiotics in the Czech Republic and restricted prescription according to the Summary of Product Characteristics as specified in the State Institute for Drug Control marketing authorisation. The expert group composed of orthopaedists, microbiologists and infectious disease specialists elaborated the basic antibiotic guideline for choosing an appropriate antibiotic/antifungal drug based on the usual susceptibility, its dose and dosage interval for initial and continuation therapy. The comments of individual specialists were gradually incorporated therein and in case of doubts majority rule was applied. The drafted document was sent for peer reviews to clinical orthopaedic, infectious disease and microbiological centres, whose comments were also incorporated and the finalised document was submitted for evaluation to specialised medical societies. RESULTS The outcome is the submitted guideline for antibiotic curative and suppressive therapy suitable for managing the prosthetic joint infections, which was approved by the committee of the Czech Society for Orthopaedics and Traumatology andthe Society for Infectious Diseases of the Czech Medical Association of J. E. Purkyně. DISCUSION Curative therapy of total joint replacement infections consists primarily in surgical treatment and has to be accompanied by adequate antibiotic therapy administered initially intravenously and later orally over a sufficient period of time. Bearing in mind the wide spectrum of pathogens that can cause infections of a joint replacement and their capacity to form a biofilm on foreign materials, the correct choice of an antibiotic, its dose and dosage interval are essential for successful treatment. Such standard should respect regional availability of antibiotics, regional pathogen resistance/susceptibility and ensure the achievement of sufficiently high concentrations at the requested location including anti-biofilm activity. CONCLUSIONS The submitted guideline is not the only treatment option for joint total replacement infections, but it makes the decisionmaking easier when treating these complications in the form of infections. The final choice of an antibiotic, its dose and duration of therapy shall be based on a critical assessment of results of microbiological (blood culture and molecular genetic) tests and reflect the patient s clinical condition. Since these are multidisciplinary issues, we consider useful for this guideline to be commented upon and approved by the committee of both the Society for Orthopaedics and Infectious Diseases so that it can become the starting point for treatment. Key words: total joint replacement infection, TEP, ATB, antibiotic therapy, consensus meeting, guideline.

  2. [Continuous insulin therapy versus multiple insulin injections in the management of type 1 diabetes: a longitutinal study].

    PubMed

    Ribeiro, Maria Estela Bellini; Del Roio Liberatore Junior, Raphael; Custodio, Rodrigo; Martinelli Junior, Carlos Eduardo

    2016-01-01

    To compare multiple doses of insulin and continuous insulin infusion therapy as treatment for type 1 diabetes melito. 40 patients with type 1 diabetes melito (21 female) with ages between 10 and 20 years (mean=14.2) and mean duration of diabetes of 7 years used multiple doses of insulin for at least 6 months and after that, continuous insulin infusion therapy for at least 6 months. Each one of the patients has used multiple doses of insulin and continuous insulin infusion therapy. For analysis of HbA1c, mean glycated hemoglobin levels (mHbA1c) were obtained during each treatment period (multiple doses of insulin and continuous insulin infusion therapy period). Although mHbA1c levels were lower during continuous insulin infusion therapy the difference was not statistically significant. During multiple doses of insulin, 14.2% had mHbA1c values below 7.5% vs. 35.71% while on continuous insulin infusion therapy; demonstrating better glycemic control with the use of continuous insulin infusion therapy. During multiple doses of insulin, 15-40 patients have severe hypoglycemic events versus 5-40 continuous insulin infusion therapy. No episodes of ketoacidosis events were recorded. This is the first study with this design comparing multiple doses of insulin and continuous insulin infusion therapy in Brazil showing no significant difference in HbA1c; hypoglycemic events were less frequent during continuous insulin infusion therapy than during multiple doses of insulin and the percentage of patients who achieved a HbA1c less than 7.5% was greater during continuous insulin infusion therapy than multiple doses of insulin therapy. Copyright © 2015 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  3. Exposure of the Heart in Breast Cancer Radiation Therapy: A Systematic Review of Heart Doses Published During 2003 to 2013

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, Carolyn W., E-mail: carolyn.taylor@ctsu.ox.ac.uk; Wang, Zhe; Macaulay, Elizabeth

    Purpose: Breast cancer radiation therapy cures many women, but where the heart is exposed, it can cause heart disease. We report a systematic review of heart doses from breast cancer radiation therapy that were published during 2003 to 2013. Methods and Materials: Eligible studies were those reporting whole-heart dose (ie, dose averaged over the whole heart). Analyses considered the arithmetic mean of the whole-heart doses for the CT plans for each regimen in each study. We termed this “mean heart dose.” Results: In left-sided breast cancer, mean heart dose averaged over all 398 regimens reported in 149 studies from 28more » countries was 5.4 Gy (range, <0.1-28.6 Gy). In regimens that did not include the internal mammary chain (IMC), average mean heart dose was 4.2 Gy and varied with the target tissues irradiated. The lowest average mean heart doses were from tangential radiation therapy with either breathing control (1.3 Gy; range, 0.4-2.5 Gy) or treatment in the lateral decubitus position (1.2 Gy; range, 0.8-1.7 Gy), or from proton radiation therapy (0.5 Gy; range, 0.1-0.8 Gy). For intensity modulated radiation therapy mean heart dose was 5.6 Gy (range, <0.1-23.0 Gy). Where the IMC was irradiated, average mean heart dose was around 8 Gy and varied little according to which other targets were irradiated. Proton radiation therapy delivered the lowest average mean heart dose (2.6 Gy, range, 1.0-6.0 Gy), and tangential radiation therapy with a separate IMC field the highest (9.2 Gy, range, 1.9-21.0 Gy). In right-sided breast cancer, the average mean heart dose was 3.3 Gy based on 45 regimens in 23 studies. Conclusions: Recent estimates of typical heart doses from left breast cancer radiation therapy vary widely between studies, even for apparently similar regimens. Maneuvers to reduce heart dose in left tangential radiation therapy were successful. Proton radiation therapy delivered the lowest doses. Inclusion of the IMC doubled typical heart dose.« less

  4. Increased duration of dual pegylated interferon and ribavirin therapy for genotype 1 hepatitis C post-liver transplantation increases sustained virologic response: a retrospective review.

    PubMed

    Wells, Malcolm M; Roth, Lee S; Marotta, Paul; Levstik, Mark; Mason, Andrew L; Bain, Vincent G; Chandok, Natasha; Aljudaibi, Bandar M

    2013-01-01

    In patients with advanced post-transplant hepatitis C virus (HCV) recurrence, antiviral treatment (AVT) with interferon and ribavirin is indicated to prevent graft failure. The aim of this study was to determine and report Canadian data with respect to the safety, efficacy, and spontaneous virologic response (SVR) predictors of AVT among transplanted patients with HCV recurrence. A retrospective chart review was performed on patients transplanted in London, Ontario and Edmonton, Alberta from 2002 to 2012 who were treated for HCV. Demographic, medical, and treatment information was collected and analyzed. A total of 85 patients with HCV received pegylated interferon with ribavirin post-liver transplantation and 28 of the 65 patients (43%) with genotype 1 achieved SVR. Of the patients having genotype 1 HCV who achieved SVR, there was a significantly lower stage of fibrosis (1.37 ± 0.88 vs. 1.89 ± 0.96; P = 0.03), increased ribavirin dose (total daily dose 1057 ± 230 vs. 856 ± 399 mg; P = 0.02), increased rapid virologic response (RVR) (6/27 vs. 0/31; P = 0.05), increased early virologic response (EVR) (28/28 vs. 18/35; P = 0.006), and longer duration of therapy (54.7 ± 13.4 weeks vs. 40.2 ± 18.7; P = 0.001). A logistic regression model using gender, age, RVR, EVR, anemia, duration of therapy, viral load, years' post-transplant, and type of organ (donation after cardiac death vs. donation after brain death) significantly predicted SVR (P < 0.001), with duration of therapy having a significant odds ratio of 1.078 (P = 0.007). This study identified factors that predict SVR in HCV-positive patients who received dual therapy post-transplantation. Extending therapy from 48 weeks to 72 weeks of dual therapy is associated with increased SVR rates. Future studies examining the role of extended therapy are needed to confirm these findings, since the current study is a retrospective one.

  5. Insulin 70/30 mix plus metformin versus triple oral therapy in the treatment of type 2 diabetes after failure of two oral drugs: efficacy, safety, and cost analysis.

    PubMed

    Schwartz, Sherwyn; Sievers, Richard; Strange, Poul; Lyness, William H; Hollander, Priscilla

    2003-08-01

    Subjects (n = 188) with type 2 diabetes and inadequate response to two oral medications (A1C >8.0%) were randomly assigned to treatment with either a third oral medication or an insulin 70/30 mix b.i.d. plus metformin for a comparison of efficacy, safety, and cost. The protocol called for aggressive dose titration to achieve target values of fasting blood glucose (80-120 mg/dl), postprandial glucose (<160 mg/dl), and A1C (<7%). These efficacy parameters were evaluated at weeks 2, 6, 12, and 24 of therapy. If dose adjustments failed to achieve targeted glycemic control, subjects were switched to an alternate therapy. At the end of study (week 24 of therapy), A1C and fasting plasma glucose (FPG) values showed comparable decreases in the two treatment groups. Only 31% (oral therapy) and 32% (insulin plus metformin) of subjects achieved target values of A1C (<7%). A total of 10 of the 98 subjects randomized to triple oral therapy (10.2%) who failed to improve sufficiently were switched to insulin therapy. An additional four subjects dropped out of the oral treatment group due to adverse events felt to be potentially drug related. Only two of the subjects randomized to insulin plus metformin had to be switched to basal-bolus regimens (regular insulin and NPH insulin). Cost analysis determined that insulin plus metformin (mean cost 3.20 dollars/day) provided efficacy equal to that of a triple oral drug regimen (10.40 dollars/day). Insulin 70/30 mix plus metformin was as effective as triple oral therapy in lowering A1C and FPG values. The triple oral regimen was not as cost effective, and a high percentage of subjects (total of 16.3%) did not complete this regimen due to lack of efficacy or side effects.

  6. Dosimetric verification of radiation therapy including intensity modulated treatments, using an amorphous-silicon electronic portal imaging device

    NASA Astrophysics Data System (ADS)

    Chytyk-Praznik, Krista Joy

    Radiation therapy is continuously increasing in complexity due to technological innovation in delivery techniques, necessitating thorough dosimetric verification. Comparing accurately predicted portal dose images to measured images obtained during patient treatment can determine if a particular treatment was delivered correctly. The goal of this thesis was to create a method to predict portal dose images that was versatile and accurate enough to use in a clinical setting. All measured images in this work were obtained with an amorphous silicon electronic portal imaging device (a-Si EPID), but the technique is applicable to any planar imager. A detailed, physics-motivated fluence model was developed to characterize fluence exiting the linear accelerator head. The model was further refined using results from Monte Carlo simulations and schematics of the linear accelerator. The fluence incident on the EPID was converted to a portal dose image through a superposition of Monte Carlo-generated, monoenergetic dose kernels specific to the a-Si EPID. Predictions of clinical IMRT fields with no patient present agreed with measured portal dose images within 3% and 3 mm. The dose kernels were applied ignoring the geometrically divergent nature of incident fluence on the EPID. A computational investigation into this parallel dose kernel assumption determined its validity under clinically relevant situations. Introducing a patient or phantom into the beam required the portal image prediction algorithm to account for patient scatter and attenuation. Primary fluence was calculated by attenuating raylines cast through the patient CT dataset, while scatter fluence was determined through the superposition of pre-calculated scatter fluence kernels. Total dose in the EPID was calculated by convolving the total predicted incident fluence with the EPID-specific dose kernels. The algorithm was tested on water slabs with square fields, agreeing with measurement within 3% and 3 mm. The method was then applied to five prostate and six head-and-neck IMRT treatment courses (˜1900 clinical images). Deviations between the predicted and measured images were quantified. The portal dose image prediction model developed in this thesis work has been shown to be accurate, and it was demonstrated to be able to verify patients' delivered radiation treatments.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hata, Masaharu; Tokuuye, Koichi; Department of Radiation Oncology, University of Tsukuba, Tsukuba, Ibaraki

    Purpose: To present treatment outcomes of hypofractionated high-dose proton beam therapy for Stage I non-small-cell lung cancer (NSCLC). Methods and Materials: Twenty-one patients with Stage I NSCLC (11 with Stage IA and 10 with Stage IB) underwent hypofractionated high-dose proton beam therapy. At the time of irradiation, patient age ranged from 51 to 85 years (median, 74 years). Nine patients were medically inoperable because of comorbidities, and 12 patients refused surgical resection. Histology was squamous cell carcinoma in 6 patients, adenocarcinoma in 14, and large cell carcinoma in 1. Tumor size ranged from 10 to 42 mm (median, 25 mm)more » in maximum diameter. Three and 18 patients received proton beam irradiation with total doses of 50 Gy and 60 Gy in 10 fractions, respectively, to primary tumor sites. Results: Of 21 patients, 2 died of cancer and 2 died of pneumonia at a median follow-up period of 25 months. The 2-year overall and cause-specific survival rates were 74% and 86%, respectively. All but one of the irradiated tumors were controlled during the follow-up period. Five patients showed recurrences 6-29 months after treatment, including local progression and new lung lesions outside of the irradiated volume in 1 and 4 patients, respectively. The local progression-free and disease-free rates were 95% and 79% at 2 years, respectively. No therapy-related toxicity of Grade {>=}3 was observed. Conclusions: Hypofractionated high-dose proton beam therapy seems feasible and effective for Stage I NSCLC. Proton beams may contribute to enhanced efficacy and lower toxicity in the treatment of patients with Stage I NSCLC.« less

  8. Analysis of a novel protocol of combined induction chemotherapy and concurrent chemoradiation in unresected non-small-cell lung cancer: a ten-year experience with vinblastine, Cisplatin, and radiation therapy.

    PubMed

    Waters, Eugenie; Dingle, Brian; Rodrigues, George; Vincent, Mark; Ash, Robert; Dar, Rashid; Inculet, Richard; Kocha, Walter; Malthaner, Richard; Sanatani, Michael; Stitt, Larry; Yaremko, Brian; Younus, Jawaid; Yu, Edward

    2010-07-01

    The London Regional Cancer Program (LRCP) uses a unique schedule of induction plus concurrent chemoradiation, termed VCRT (vinblastine, cisplatin, and radiation therapy), for the treatment of a subset of unresectable stage IIIA and IIIB non-small-cell lung cancer (NSCLC). This analysis was conducted to better understand the outcomes in VCRT-treated patients. We report a retrospective analysis of a large cohort of patients who underwent VCRT at the LRCP over a 10-year period, from 1996 to 2006. The analysis focused on OS, toxicities, and the outcomes from completion surgery in a small subset of patients. A total of 294 patients were included and 5-year OS, determined using Kaplan-Meier methodology, was 19.8% with a MST of 18.2 months. Reported grade 3-4 toxicities included neutropenia (39%), anemia (10%), pneumonitis (1%), and esophagitis (3%). Significant differences in survival between groups of patients were demonstrated with log-rank tests for completion surgery, use of radiation therapy, and cisplatin dose. Similarly, Univariate Cox regression showed that completion surgery, use of radiation therapy, cisplatin dose, and vinblastine dose were associated with increased survival. This retrospective analysis of a large cohort of patients reveals an OS for VCRT comparable to that reported in the literature for other current combined chemoradiation protocols. The success of this protocol seems to be dose dependent and the outcomes in those who underwent completion surgery suggests that pathologic complete remission is possible for IIIA and IIIB NSCLC.

  9. Development of a vancomycin dosing approach for critically ill patients receiving hybrid hemodialysis using Monte Carlo simulation.

    PubMed

    Lewis, Susan J; Mueller, Bruce A

    2018-01-01

    Prolonged intermittent renal replacement therapy is an increasingly popular treatment for acute kidney injury in critically ill patients that runs at different flow rates and durations than conventional hemodialysis or continuous renal replacement therapies. Pharmacokinetic studies conducted in patients receiving prolonged intermittent renal replacement therapy are scarce; consequently, clinicians are challenged to dose antibiotics effectively. The purpose of this study was to develop vancomycin dosing recommendations for patients receiving prolonged intermittent renal replacement therapy. Monte Carlo simulations were performed in thousands of virtual patients derived from previously published demographic, pharmacokinetic, and dialytic information derived from critically ill patients receiving vancomycin and other forms of renal replacement therapy. We conducted "in silico" vancomycin pharmacokinetic/pharmacodynamics analyses in these patients receiving prolonged intermittent renal replacement therapy to determine what vancomycin dose would achieve vancomycin 24-h area under the curve (AUC 24h ) of 400-700 mg·h/L, a target associated with positive clinical outcomes. Nine different vancomycin dosing regimens were tested using four different, commonly used prolonged intermittent renal replacement therapy modalities. A dosing nomogram based on serum concentration data achieved after the third dose was developed to individualize vancomycin therapy. An initial vancomycin dose of 15 or 20 mg/kg immediately followed by 15 mg/kg after subsequent prolonged intermittent renal replacement therapy treatments achieved AUC 24h of ≥400 mg·h/L for ≥90% of patients regardless of prolonged intermittent renal replacement therapy duration, modality, or time of vancomycin dose relative to prolonged intermittent renal replacement therapy. Many patients experienced AUC 24h of ≥700 mg·h/L, but once the dosing nomogram was applied to serum concentrations obtained after the third vancomycin dose, 67%-88% of patients achieved AUC 24h of 400-700 mg·h/L. An initial loading dose of 15-20 mg/kg followed by a maintenance regimen of 15 mg/kg after every prolonged intermittent renal replacement therapy session coupled with serum concentration monitoring should be used to individualize vancomycin dosing. These predictions need clinical verification.

  10. Short-term therapy with relatively low-dose cerivastatin improves endothelial function independently of its lipid-lowering effect: Evaluation of brachial artery vasodilatation using B-mode ultrasound imaging.

    PubMed

    Sakabe, Koichi; Fukuda, Nobuo; Nada, Teru; Onose, Yukiko; Soeki, Takeshi; Shinohara, Hisanori; Tamura, Yoshiyuki

    2002-12-01

    Administration of 0.4 to 0.8 mg of cerivastatin per day for 2 weeks has been reported to have pleiotropic effects and improve endothelial function. Whether low-dose cerivastatin would produce these rapid pleiotropic effects in the clinical setting remains uncertain, however. We investigated the effect of short-term therapy with relatively low-dose cerivastatin (0.15 mg/day) on endothelial function, thrombostatic parameters, and C-reactive protein (CRP) levels in hypercholesterolemic patients. Thirteen patients with LDL-cholesterol>160 mg/dl were treated with daily doses of 0.15 mg of cerivastatin for 2 weeks. Endothelial function, thrombostatic parameters (tissue-type plasminogen activator [t-PA], plasminogen activator inhibitor type 1 [PAI-1], and CRP were estimated at baseline and again after 2 weeks of treatment. Endothelial function was measured as flow-mediated vasodilation. Flow-mediated vasodilatation was assessed by measuring the percent change in the diameter of the brachial artery in response to reactive hyperemia using high-resolution ultrasound. Endothelium-independent vasodilatation was also measured using sublingual nitroglycerin. No major complications developed after the treatment. Total cholesterol decreased significantly, from 258±32 to 211±21 mg/dl, and LDL-cholesterol also decreased from 171±15 to 133±16 mg/dl after the treatment. Flow-mediated vasodilatation increased significantly, from 4.6±1.3 percent to 8.7±3.5 percent after 2 weeks of therapy, although endothelium-independent vasodilatation was not affected (9.5±2.4% vs 8.8±3.1%). No relation was found between percent change in flow-mediated vasodilatation and improvement in levels of LDL-cholesterol after therapy (r=0.07). PAI-1, t-PA, and CRP were not significantly changed by 2 weeks of therapy. (1) Evaluating vasodilation of the brachial artery with B-mode ultrasound imaging was useful in investigating the effect of statin on endothelial function. (2) Although no effect was detected in PAI-1, t-PA, or CRP, relatively low-dose cerivastatin therapy for 2 weeks improved endothelial function and lipid level independently and safely in hypercholesterolemic patients.

  11. Limb Blood Flow After Class 4 Laser Therapy

    PubMed Central

    Larkin, Kelly A.; Martin, Jeffrey S.; Zeanah, Elizabeth H.; True, Jerry M.; Braith, Randy W.; Borsa, Paul A.

    2012-01-01

    Context: Laser therapy is purported to improve blood flow in soft tissues. Modulating circulation would promote healing by controlling postinjury ischemia, hypoxia, edema, and secondary tissue damage. However, no studies have quantified these responses to laser therapy. Objective: To determine a therapeutic dose range for laser therapy for increasing blood flow to the forearm. Design: Crossover study. Setting: Controlled laboratory setting. Patients or Other Participants: Ten healthy, college-aged men (age = 20.80 ± 2.16 years, height = 177.93 ± 3.38 cm, weight = 73.64 ± 9.10 kg) with no current history of injury to the upper extremity or cardiovascular conditions. Intervention(s): A class 4 laser device was used to treat the biceps brachii muscle. Each grid point was treated for 3 to 4 seconds, for a total of 4 minutes. Each participant received 4 doses of laser therapy: sham, 1 W, 3 W, and 6 W. Main Outcome Measure(s): The dependent variables were changes in blood flow, measured using venous occlusion plethysmography. We used a repeated-measures analysis of variance to analyze changes in blood flow for each dose at 2, 3, and 4 minutes and at 1, 2, 3, 4, and 5 minutes after treatment. The Huynh-Feldt test was conducted to examine differences over time. Results: Compared with baseline, blood flow increased over time with the 3-W treatment (F3,9 = 3.468, P < .011) at minute 4 of treatment (2.417 ± 0.342 versus 2.794 ± 0.351 mL/min per 100 mL tissue, P = .032), and at 1 minute (2.767 ± 0.358 mL/min per 100 mL tissue, P < .01) and 2 minutes (2.657 ± 0.369 mL/min per 100 mL tissue, P = .022) after treatment. The sham, 1-W, and 6-W treatment doses did not change blood flow from baseline at any time point. Conclusions: Laser therapy at the 3-W (360-J) dose level was an effective treatment modality to increase blood flow in the soft tissues. PMID:22488283

  12. Comparison of therapy augmentation and deviation rates from the recommended once-daily dosing regimen between LDX and commonly prescribed long-acting stimulants for the treatment of ADHD in youth and adults.

    PubMed

    Setyawan, Juliana; Hodgkins, Paul; Guérin, Annie; Gauthier, Geneviève; Cloutier, Martin; Wu, Eric; Erder, M Haim

    2013-10-01

    To compare therapy augmentation and deviation rates from the recommended once-daily dosing regimen in Attention Deficit Hyperactivity Disorder (ADHD) patients initiated on lisdexamfetamine (LDX) vs other once-daily Food and Drug Administration (FDA) approved stimulants. ADHD patients initiated on a long-acting ADHD stimulant medication (index medication) in/after 2007 were selected from a large U.S. administrative claims database. Patients were required to be persistent for ≥90 days and continuously enrolled in their healthcare plan for ≥12 months following treatment initiation date. Based on age and previous treatment status, patients were classified into treatment-naïve children and adolescents (6-17 years old), previously treated children and adolescents, treatment-naïve adults (≥18 years old), and previously treated adults. Furthermore, patients were classified into four mutually exclusive treatment groups, based on index medication: lisdexamfetamine (LDX), osmotic release methylphenidate hydrochloride long-acting (OROS MPH), other methylphenidate/dexmethylphenidate long-acting (MPH LA), and amphetamine/dextroamphetamine long-acting (AMPH LA). The average daily consumption was measured as the quantity of index medication supplied in the 12-month study period divided by the total number of days of supply. Therapy augmentation was defined as the use of another ADHD medication concomitantly with the index medication for ≥28 consecutive days. Therapy augmentation and deviation rates from the recommended once-daily dosing regimen were compared between treatment groups using multivariate logistic regression models. Compared to the other treatment groups, LDX patients were less likely to augment with another ADHD medication (range odds ratios [OR]; 1.28-3.30) and to deviate from the recommended once-daily dosing regimen (range OR; 1.73-4.55), except for previously treated adult patients, where therapy augmentation differences were not statistically significant when compared to OROS MPH and MPH LA patients. This study did not control for ADHD severity. Overall, compared to LDX-treated patients, patients initiated on other ADHD medications were equally or more likely to have a therapy augmentation and more likely to deviate from the recommended once-daily dosing regimen.

  13. Overcoming severe adverse reactions to venom immunotherapy using anti-IgE antibodies in combination with a high maintenance dose.

    PubMed

    Stretz, E; Oppel, E M; Räwer, H-C; Chatelain, R; Mastnik, S; Przybilla, B; Ruëff, F

    2017-12-01

    An omalizumab treatment and a high maintenance venom dose may both help to prevent recurrent systemic allergic reactions (SAR) to venom immunotherapy (VIT). The effectiveness of this combination therapy, however, is unclear. We wanted to explore the possibility whether a temporary treatment with the anti-IgE antibody omalizumab combined with a VIT using an elevated maintenance dose of >100 μg venom may establish a permanent tolerance of maintenance VIT. For this retrospective case series, we scoured our institutional data base for patients who had had an insect venom allergy, and in whom it had not been possible to continue VIT because of repeated unstoppable SAR during maintenance VIT. Patients were divided into those who had received the combination therapy (omalizumab group) and those who had not received omalizumab because its costs could not be covered (controls). Guided by the total IgE level and by body weight, omalizumab had been given subcutaneously 5, 3 and 1 weeks before VIT had been restarted. Three to 6 months after an elevated maintenance dose (200-300 μg venom) had been reached, omalizumab had been stopped. Between 2006 and 2011, 15 patients had qualified for an off-label use of omalizumab: 10 patients had received the combination therapy, and 5 patients had remained without such a therapy. The combination therapy leads to a durable tolerance of VIT in all patients even after omalizumab had been discontinued (median of follow-up time 5.8 years, IQR 2.7-8.6 years). Sting challenge tests were tolerated by all of the re-stung omalizumab patients (n = 8). In all controls, VIT had to be stopped permanently due to repeated SARs (P < .001 vs omalizumab group). Combining a temporary omalizumab therapy with an elevated maintenance dose seems a promising approach to achieve a tolerance of treatment in patients with a recurrent SAR to VIT. © 2017 John Wiley & Sons Ltd.

  14. [Comparison of planning quality and delivery efficiency between volumetric modulated arc therapy and dynamic intensity modulated radiation therapy for nasopharyngeal carcinoma with more than 4 prescribed dose levels].

    PubMed

    Jia, Pengfei; Xu, Jun; Zhou, Xiaoxi; Chen, Jian; Tang, Lemin

    2017-12-01

    The aim of this study is to compare the planning quality and delivery efficiency between dynamic intensity modulated radiation therapy (d-IMRT) and dual arc volumetric modulated arc therapy (VMAT) systematically for nasopharyngeal carcinoma (NPC) patients with multi-prescribed dose levels, and to analyze the correlations between target volumes and plan qualities. A total of 20 patients of NPC with 4-5 prescribed dose levels to achieve simultaneous integrated boost (SIB) treated by sliding window d-IMRT in our department from 2014 to 2015 were re-planned with dual arc VMAT. All optimization objectives for each VMAT plan were as the same as the corresponding d-IMRT plan. The dose parameters for targets and organ at risk (OAR), the delivery time and monitor units (MU) in two sets of plans were compared respectively. The treatment accuracy was tested by three dimensional dose validation system. Finally, the correlations between the difference of planning quality and the volume of targets were discussed. The conform indexes (CIs) of planning target volumes (PTVs) in VMAT plans were obviously high than those in d-IMRT plans ( P < 0.05), but no significant correlations between the difference of CIs and the volume of targets were discovered ( P > 0.05). The target coverage and heterogeneity indexes (HIs) of PTV 1 and PGTV nd and PTV 3 in two sets of plans were consistent. The doses of PTV 2 decreased and HIs were worse in VMAT plans. VMAT could provide better spinal cord and brainstem sparing, but increase mean dose of parotids. The average number of MUs and delivery time for d-IMRT were 3.32 and 2.19 times of that for VMAT. The γ-index (3 mm, 3%) analysis for each plans was more than 97% in COMPASS ® measurement for quality assurance (QA). The results show that target dose coverages in d-IMRT and VMAT plans are similar for NPC with multi-prescribed dose levels. VMAT could improve the the CIs of targets, but reduce the dose to the target volume in neck except for PGTV nd . The biggest advantages of VMAT over d-IMRT are delivery efficiency and QA.

  15. Late Effects in Pediatric High-risk Neuroblastoma Survivors After Intensive Induction Chemotherapy Followed by Myeloablative Consolidation Chemotherapy and Triple Autologous Stem Cell Transplants.

    PubMed

    Armstrong, Amy E; Danner-Koptik, Karina; Golden, Shannon; Schneiderman, Jennifer; Kletzel, Morris; Reichek, Jennifer; Gosiengfiao, Yasmin

    2018-01-01

    Multimodal treatment in high-risk neuroblastoma has modestly improved survival; limited data exist on the late effects from these regimens. We report the sequelae of treatment incorporating 3 consecutive cycles of high-dose therapy and autologous stem cell transplants (ASCTs) without the use of total body irradiation (TBI). We reviewed the medical records of 61 patients treated on or following the Chicago Pilot 2 protocol between 1991 and 2008. Of the 25 patients who are alive (41%), 19 had near complete data to report. Specific treatment modalities and therapy-related side effects were collected. Fourteen of these 19 patients (74%) received 3 cycles of high-dose therapy with ASCT; follow-up occurred over a median of 13.9 years (range, 5.8 to 18.8 y). The majority of late effects were endocrine-related, including growth failure, hypothyroidism, and hypogonadism. Patients also developed secondary neoplasms and skeletal deformities. The most frequent sequela was hearing loss, seen in 17/19 patients. We found a high prevalence of various late effects in survivors of high-risk neuroblastoma using a non-TBI-based regimen including 3 cycles of high-dose therapy with ASCTs. As current treatment regimens recommend tandem ASCT without TBI, it is imperative that we understand and monitor for the sequelae from these modalities.

  16. SU-F-I-09: Improvement of Image Registration Using Total-Variation Based Noise Reduction Algorithms for Low-Dose CBCT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mukherjee, S; Farr, J; Merchant, T

    Purpose: To study the effect of total-variation based noise reduction algorithms to improve the image registration of low-dose CBCT for patient positioning in radiation therapy. Methods: In low-dose CBCT, the reconstructed image is degraded by excessive quantum noise. In this study, we developed a total-variation based noise reduction algorithm and studied the effect of the algorithm on noise reduction and image registration accuracy. To study the effect of noise reduction, we have calculated the peak signal-to-noise ratio (PSNR). To study the improvement of image registration, we performed image registration between volumetric CT and MV- CBCT images of different head-and-neck patientsmore » and calculated the mutual information (MI) and Pearson correlation coefficient (PCC) as a similarity metric. The PSNR, MI and PCC were calculated for both the noisy and noise-reduced CBCT images. Results: The algorithms were shown to be effective in reducing the noise level and improving the MI and PCC for the low-dose CBCT images tested. For the different head-and-neck patients, a maximum improvement of PSNR of 10 dB with respect to the noisy image was calculated. The improvement of MI and PCC was 9% and 2% respectively. Conclusion: Total-variation based noise reduction algorithm was studied to improve the image registration between CT and low-dose CBCT. The algorithm had shown promising results in reducing the noise from low-dose CBCT images and improving the similarity metric in terms of MI and PCC.« less

  17. SU-E-T-628: Predicted Risk of Post-Irradiation Cerebral Necrosis in Pediatric Brain Cancer Patients: A Treatment Planning Comparison of Proton Vs. Photon Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freund, D; Zhang, R; Sanders, M

    Purpose: Post-irradiation cerebral necrosis (PICN) is a severe late effect that can Result from brain cancers treatment using radiation therapy. The purpose of this study was to compare the treatment plans and predicted risk of PICN after volumetric modulated arc therapy (VMAT) to the risk after passively scattered proton therapy (PSPT) and intensity modulated proton therapy (IMPT) in a cohort of pediatric patients. Methods: Thirteen pediatric patients with varying age and sex were selected for this study. A clinical treatment volume (CTV) was constructed for 8 glioma patients and 5 ependymoma patients. Prescribed dose was 54 Gy over 30 fractionsmore » to the planning volume. Dosimetric endpoints were compared between VMAT and proton plans. The normal tissue complication probability (NTCP) following VMAT and proton therapy planning was also calculated using PICN as the biological endpoint. Sensitivity tests were performed to determine if predicted risk of PICN was sensitive to positional errors, proton range errors and selection of risk models. Results: Both PSPT and IMPT plans resulted in a significant increase in the maximum dose and reduction in the total brain volume irradiated to low doses compared with the VMAT plans. The average ratios of NTCP between PSPT and VMAT were 0.56 and 0.38 for glioma and ependymoma patients respectively and the average ratios of NTCP between IMPT and VMAT were 0.67 and 0.68 for glioma and ependymoma plans respectively. Sensitivity test revealed that predicted ratios of risk were insensitive to range and positional errors but varied with risk model selection. Conclusion: Both PSPT and IMPT plans resulted in a decrease in the predictive risk of necrosis for the pediatric plans studied in this work. Sensitivity analysis upheld the qualitative findings of the risk models used in this study, however more accurate models that take into account dose and volume are needed.« less

  18. Adaptive, dose-finding phase 2 trial evaluating the safety and efficacy of ABT-089 in mild to moderate Alzheimer disease.

    PubMed

    Lenz, Robert A; Pritchett, Yili L; Berry, Scott M; Llano, Daniel A; Han, Shu; Berry, Donald A; Sadowsky, Carl H; Abi-Saab, Walid M; Saltarelli, Mario D

    2015-01-01

    ABT-089, an α4β2 neuronal nicotinic receptor partial agonist, was evaluated for efficacy and safety in mild to moderate Alzheimer disease patients receiving stable doses of acetylcholinesterase inhibitors. This phase 2 double-blind, placebo-controlled, proof-of-concept, and dose-finding study adaptively randomized patients to receive ABT-089 (5, 10, 15, 20, 30, or 35 mg once daily) or placebo for 12 weeks. The primary efficacy endpoint was the Alzheimer's Disease Assessment Scale, cognition subscale (ADAS-Cog) total score. A Bayesian response-adaptive randomization algorithm dynamically assigned allocation probabilities based on interim ADAS-Cog total scores. A normal dynamic linear model for dose-response relationships and a longitudinal model for predicting final ADAS-cog score were employed in the algorithm. Stopping criteria for futility or success were defined. The futility stopping criterion was met, terminating the study with 337 patients randomized. No dose-response relationship was observed and no dose demonstrated statistically significant improvement over placebo on ADAS-Cog or any secondary endpoint. ABT-089 was well tolerated at all dose levels. When administered as adjunctive therapy to acetylcholinesterase inhibitors, ABT-089 was not efficacious in mild to moderate Alzheimer disease. The adaptive study design enabled the examination of a broad dose range, enabled rapid determination of futility, and reduced patient exposure to nonefficacious doses of the investigational compound.

  19. Graves' disease radioiodine-therapy: Choosing target absorbed doses for therapy planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willegaignon, J., E-mail: j.willegaignon@gmail.com; Sapienza, M. T.; Coura-Filho, G. B.

    Purpose: The precise determination of organ mass (m{sub th}) and total number of disintegrations within the thyroid gland (A{sup ~}) are essential for thyroid absorbed-dose calculations for radioiodine therapy. Nevertheless, these parameters may vary according to the method employed for their estimation, thus introducing uncertainty in the estimated thyroid absorbed dose and in any dose–response relationship derived using such estimates. In consideration of these points, thyroid absorbed doses for Graves’ disease (GD) treatment planning were calculated using different approaches to estimating the m{sub th} and the A{sup ~}. Methods: Fifty patients were included in the study. Thyroid{sup 131}I uptake measurementsmore » were performed at 2, 6, 24, 48, 96, and 220 h postadministration of a tracer activity in order to estimate the effective half-time (T{sub eff}) of {sup 131}I in the thyroid; the thyroid cumulated activity was then estimated using the T{sub eff} thus determined or, alternatively, calculated by numeric integration of the measured time-activity data. Thyroid mass was estimated by ultrasonography (USG) and scintigraphy (SCTG). Absorbed doses were calculated with the OLINDA/EXM software. The relationships between thyroid absorbed dose and therapy response were evaluated at 3 months and 1 year after therapy. Results: The average ratio (±1 standard deviation) betweenm{sub th} estimated by SCTG and USG was 1.74 (±0.64) and that between A{sup ~} obtained by T{sub eff} and the integration of measured activity in the gland was 1.71 (±0.14). These differences affect the calculated absorbed dose. Overall, therapeutic success, corresponding to induction of durable hypothyroidism or euthyroidism, was achieved in 72% of all patients at 3 months and in 90% at 1 year. A therapeutic success rate of at least 95% was found in the group of patients receiving doses of 200 Gy (p = 0.0483) and 330 Gy (p = 0.0131) when m{sub th} was measured by either USG or SCTG and A{sup ~} was determined by the integration of measured {sup 131}I activity in the thyroid gland and based on T{sub eff}, respectively. No statistically significant relationship was found between therapeutic response and patients’ age, administered {sup 131}I activity (MBq), 24-h thyroid {sup 131}I uptake (%) or T{sub eff} (p ≥ 0.064); nonetheless, a good relationship was found between the therapeutic response and m{sub th} (p ≤ 0.035). Conclusions: According to the results of this study, the most effective thyroid absorbed dose to be targeted in GD therapy should not be based on a fixed dose but rather should be individualized based on the patient'sm{sub th} and A{sup ~}. To achieve a therapeutic success (i.e., durable euthyroidism or hypothyroidism) rate of at least 95%, a thyroid absorbed dose of 200 or 330 Gy is required depending on the methodology used for estimating m{sub th} and A{sup ~}.« less

  20. Graves' disease radioiodine-therapy: Choosing target absorbed doses for therapy planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willegaignon, J., E-mail: j.willegaignon@gmail.com; Sapienza, M. T.; Coura-Filho, G. B.

    2014-01-15

    Purpose: The precise determination of organ mass (m{sub th}) and total number of disintegrations within the thyroid gland (A{sup ~}) are essential for thyroid absorbed-dose calculations for radioiodine therapy. Nevertheless, these parameters may vary according to the method employed for their estimation, thus introducing uncertainty in the estimated thyroid absorbed dose and in any dose–response relationship derived using such estimates. In consideration of these points, thyroid absorbed doses for Graves’ disease (GD) treatment planning were calculated using different approaches to estimating the m{sub th} and the A{sup ~}. Methods: Fifty patients were included in the study. Thyroid{sup 131}I uptake measurementsmore » were performed at 2, 6, 24, 48, 96, and 220 h postadministration of a tracer activity in order to estimate the effective half-time (T{sub eff}) of {sup 131}I in the thyroid; the thyroid cumulated activity was then estimated using the T{sub eff} thus determined or, alternatively, calculated by numeric integration of the measured time-activity data. Thyroid mass was estimated by ultrasonography (USG) and scintigraphy (SCTG). Absorbed doses were calculated with the OLINDA/EXM software. The relationships between thyroid absorbed dose and therapy response were evaluated at 3 months and 1 year after therapy. Results: The average ratio (±1 standard deviation) betweenm{sub th} estimated by SCTG and USG was 1.74 (±0.64) and that between A{sup ~} obtained by T{sub eff} and the integration of measured activity in the gland was 1.71 (±0.14). These differences affect the calculated absorbed dose. Overall, therapeutic success, corresponding to induction of durable hypothyroidism or euthyroidism, was achieved in 72% of all patients at 3 months and in 90% at 1 year. A therapeutic success rate of at least 95% was found in the group of patients receiving doses of 200 Gy (p = 0.0483) and 330 Gy (p = 0.0131) when m{sub th} was measured by either USG or SCTG and A{sup ~} was determined by the integration of measured {sup 131}I activity in the thyroid gland and based on T{sub eff}, respectively. No statistically significant relationship was found between therapeutic response and patients’ age, administered {sup 131}I activity (MBq), 24-h thyroid {sup 131}I uptake (%) or T{sub eff} (p ≥ 0.064); nonetheless, a good relationship was found between the therapeutic response and m{sub th} (p ≤ 0.035). Conclusions: According to the results of this study, the most effective thyroid absorbed dose to be targeted in GD therapy should not be based on a fixed dose but rather should be individualized based on the patient'sm{sub th} and A{sup ~}. To achieve a therapeutic success (i.e., durable euthyroidism or hypothyroidism) rate of at least 95%, a thyroid absorbed dose of 200 or 330 Gy is required depending on the methodology used for estimating m{sub th} and A{sup ~}.« less

  1. Validation of GPU based TomoTherapy dose calculation engine.

    PubMed

    Chen, Quan; Lu, Weiguo; Chen, Yu; Chen, Mingli; Henderson, Douglas; Sterpin, Edmond

    2012-04-01

    The graphic processing unit (GPU) based TomoTherapy convolution/superposition(C/S) dose engine (GPU dose engine) achieves a dramatic performance improvement over the traditional CPU-cluster based TomoTherapy dose engine (CPU dose engine). Besides the architecture difference between the GPU and CPU, there are several algorithm changes from the CPU dose engine to the GPU dose engine. These changes made the GPU dose slightly different from the CPU-cluster dose. In order for the commercial release of the GPU dose engine, its accuracy has to be validated. Thirty eight TomoTherapy phantom plans and 19 patient plans were calculated with both dose engines to evaluate the equivalency between the two dose engines. Gamma indices (Γ) were used for the equivalency evaluation. The GPU dose was further verified with the absolute point dose measurement with ion chamber and film measurements for phantom plans. Monte Carlo calculation was used as a reference for both dose engines in the accuracy evaluation in heterogeneous phantom and actual patients. The GPU dose engine showed excellent agreement with the current CPU dose engine. The majority of cases had over 99.99% of voxels with Γ(1%, 1 mm) < 1. The worst case observed in the phantom had 0.22% voxels violating the criterion. In patient cases, the worst percentage of voxels violating the criterion was 0.57%. For absolute point dose verification, all cases agreed with measurement to within ±3% with average error magnitude within 1%. All cases passed the acceptance criterion that more than 95% of the pixels have Γ(3%, 3 mm) < 1 in film measurement, and the average passing pixel percentage is 98.5%-99%. The GPU dose engine also showed similar degree of accuracy in heterogeneous media as the current TomoTherapy dose engine. It is verified and validated that the ultrafast TomoTherapy GPU dose engine can safely replace the existing TomoTherapy cluster based dose engine without degradation in dose accuracy.

  2. Low-dose Photofrin-induced PDT offers excellent clinical response with minimal morbidity in chest wall recurrence of breast cancer

    NASA Astrophysics Data System (ADS)

    Allison, Ron; Mang, Thomas S.

    2000-03-01

    Limited therapeutic options exist when chest wall recurrence form breast cancer progresses despite standard salvage treatment. As photodynamic therapy offers excellent response for cutaneous lesions this may be a possible indication for PDT. A total of 102 treatment fields were illuminated on 9 women with biopsy proven chest wall recurrence of breast cancer which was progressing despite salvage surgery, radiation, and chemi-hormonal therapy. PDT consisted of outpatient IV infusion of Photofrin at 0.8 mg/kg followed 48 hours laser by illumination at 140-170 J/cm2 via a KTP Yag laser coupled to a dye unit. No patient was lost to follow up. At 6 months post PDT; complete response, defined as total lesion elimination was 89 percent, partial response 8 percent, and no response 3 percent. No photosensitivity was seen and no patient developed scarring, fibrosis, or healing difficulties. Low dose Photofrin induced PDT is very active against chest wall lesions. Despite fragile and heavily pre-treated tissues, excellent clinical and cosmetic outcome was obtained. PDT is an underutilized modality for this indication.

  3. Proton Beam Therapy Interference With Implanted Cardiac Pacemakers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oshiro, Yoshiko; Sugahara, Shinji; Noma, Mio

    2008-11-01

    Purpose: To investigate the effect of proton beam therapy (PBT) on implanted cardiac pacemaker function. Methods and Materials: After a phantom study confirmed the safety of PBT in patients with cardiac pacemakers, we treated 8 patients with implanted pacemakers using PBT to a total tumor dose of 33-77 gray equivalents (GyE) in dose fractions of 2.2-6.6 GyE. The combined total number of PBT sessions was 127. Although all pulse generators remained outside the treatment field, 4 patients had pacing leads in the radiation field. All patients were monitored by means of electrocardiogram during treatment, and pacemakers were routinely examined beforemore » and after PBT. Results: The phantom study showed no effect of neutron scatter on pacemaker generators. In the study, changes in heart rate occurred three times (2.4%) in 2 patients. However, these patients remained completely asymptomatic throughout the PBT course. Conclusions: PBT can result in pacemaker malfunctions that manifest as changes in pulse rate and pulse patterns. Therefore, patients with cardiac pacemakers should be monitored by means of electrocardiogram during PBT.« less

  4. Current dosing of low-molecular-weight heparins does not reflect licensed product labels: an international survey

    PubMed Central

    Barras, Michael A; Kirkpatrick, Carl M J; Green, Bruce

    2010-01-01

    AIMS Low-molecular-weight heparins (LMWHs) are used globally to treat thromboembolic diseases; however, there is much debate on how to prescribe effectively for patients who have renal impairment and/or obesity. We aimed to investigate the strategies used to dose-individualize LMWH therapy. METHODS We conducted an online survey of selected hospitals in Australia, New Zealand (NZ), United Kingdom (UK) and the United States (US). Outcome measures included: the percentage of hospitals which recommended that LMWHs were prescribed according to the product label (PL), the percentage of hospitals that dose-individualized LMWHs outside the PL based on renal function, body weight and anti-Xa activity and a summary of methods used to dose-individualize therapy. RESULTS A total of 257 surveys were suitable for analysis: 84 (33%) from Australia, 79 (31%) from the UK, 73 (28%) from the US and 21 (8%) from NZ. Formal dosing protocols were used in 207 (81%) hospitals, of which 198 (96%) did not adhere to the PL. Of these 198 hospitals, 175 (87%) preferred to dose-individualize based on renal function, 128 (62%) on body weight and 48 (23%) by monitoring anti-Xa activity. All three of these variables were used in 29 (14%) hospitals, 98 (47%) used two variables and 71 (34%) used only one variable. CONCLUSIONS Dose-individualization strategies for LMWHs, which contravene the PL, were present in 96% of surveyed hospitals. Common individualization methods included dose-capping, use of lean body size descriptors to calculate renal function and the starting dose, followed by post dose anti-Xa monitoring. PMID:20573088

  5. Current dosing of low-molecular-weight heparins does not reflect licensed product labels: an international survey.

    PubMed

    Barras, Michael A; Kirkpatrick, Carl M J; Green, Bruce

    2010-05-01

    Low-molecular-weight heparins (LMWHs) are used globally to treat thromboembolic diseases; however, there is much debate on how to prescribe effectively for patients who have renal impairment and/or obesity. We aimed to investigate the strategies used to dose-individualize LMWH therapy. We conducted an online survey of selected hospitals in Australia, New Zealand (NZ), United Kingdom (UK) and the United States (US). Outcome measures included: the percentage of hospitals which recommended that LMWHs were prescribed according to the product label (PL), the percentage of hospitals that dose-individualized LMWHs outside the PL based on renal function, body weight and anti-Xa activity and a summary of methods used to dose-individualize therapy. A total of 257 surveys were suitable for analysis: 84 (33%) from Australia, 79 (31%) from the UK, 73 (28%) from the US and 21 (8%) from NZ. Formal dosing protocols were used in 207 (81%) hospitals, of which 198 (96%) did not adhere to the PL. Of these 198 hospitals, 175 (87%) preferred to dose-individualize based on renal function, 128 (62%) on body weight and 48 (23%) by monitoring anti-Xa activity. All three of these variables were used in 29 (14%) hospitals, 98 (47%) used two variables and 71 (34%) used only one variable. Dose-individualization strategies for LMWHs, which contravene the PL, were present in 96% of surveyed hospitals. Common individualization methods included dose-capping, use of lean body size descriptors to calculate renal function and the starting dose, followed by post dose anti-Xa monitoring.

  6. Esophageal Dose Tolerance in Patients Treated With Stereotactic Body Radiation Therapy.

    PubMed

    Nuyttens, Joost J; Moiseenko, Vitali; McLaughlin, Mark; Jain, Sheena; Herbert, Scott; Grimm, Jimm

    2016-04-01

    Mediastinal critical structures such as trachea, bronchus, esophagus, and heart are among the dose-limiting factors for stereotactic body radiation therapy (SBRT) to central lung lesions. The purpose of this study was to characterize the risk of esophagitis for patients treated with SBRT and to develop a statistical dose-response model to assess the equivalent uniform dose, D10%, D5cc, D1cc, and Dmax, to the esophagus and the risk of toxicity. Toxicity outcomes of a dose-escalation study of 56 patients who had taken CyberKnife treatment from 45-60Gy in 3-7 fractions at the Erasmus MC-Daniel den Hoed Cancer Center were utilized to create the dose-response model for esophagus. A total of 5 grade 2 esophageal complications were reported (Common Terminology Criteria for Adverse Events version 3.0); 4 complications were early effects and 1 complication was a late effect. All analyses were performed in terms of 5-fraction equivalent dosing. According to our study, D1cc at a dose of 32.9Gy and Dmax dose of 43.4Gy corresponded to a complication probability of 50% for grade 2 toxicity. In this series of 58 CyberKnife mediastinal lung cases, no grade 3 or higher esophageal toxicity occurred. Our estimates of esophageal toxicity are compared with the data in the literature. Further research needs to be performed to establish more reliable dose limits as longer follow-up and toxicity outcomes are reported in patients treated with SBRT for central lung lesions. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Local control rates of metastatic renal cell carcinoma (RCC) to the bone using stereotactic body radiation therapy: Is RCC truly radioresistant?

    PubMed

    Amini, Arya; Altoos, Basel; Bourlon, Maria T; Bedrick, Edward; Bhatia, Shilpa; Kessler, Elizabeth R; Flaig, Thomas W; Fisher, Christine M; Kavanagh, Brian D; Lam, Elaine T; Karam, Sana D

    2015-01-01

    We report the radiographic and clinical response rate of stereotactic body radiation therapy (SBRT) compared with conventional fractionated external beam radiation therapy (CF-EBRT) for renal cell carcinoma (RCC) bone lesions treated at our institution. Forty-six consecutive patients were included in the study, with 95 total lesions treated (50 SBRT, 45 CF-EBRT). We included patients who had histologic confirmation of primary RCC and radiographic evidence of metastatic bone lesions. The most common SBRT regimen used was 27 Gy in 3 fractions. Median follow-up was 10 months (range, 1-64 months). Median time to symptom control between SBRT and CF-EBRT were 2 (range, 0-6 weeks) and 4 weeks (range, 0-7 weeks), respectively. Symptom control rates with SBRT and CF-EBRT were significantly different (P = .020) with control rates at 10, 12, and 24 months of 74.9% versus 44.1%, 74.9% versus 39.9%, and 74.9% versus 35.7%, respectively. The median time to radiographic failure and unadjusted pain progression was 7 months in both groups. When controlling for gross tumor volume, dose per fraction, smoking, and the use of systemic therapy, biologically effective dose ≥80 Gy was significant for clinical response (hazard ratio [HR], 0.204; 95% confidence interval [CI], 0.043-0.963; P = .046) and radiographic (HR, 0.075; 95% CI, 0.013-0.430; P = .004). When controlling for gross tumor volume and total dose, biologically effective dose ≥80 Gy was again predictive of clinical local control (HR, 0.140; 95% CI, 0.025-0.787; P = .026). Toxicity rates were low and equivalent in both groups, with no grade 4 or 5 toxicity reported. SBRT is both safe and effective for treating RCC bone metastases, with rapid improvement in symptoms after treatment and more durable clinical and radiographic response rate. Future prospective trials are needed to further define efficacy and toxicity of treatment, especially in the setting of targeted agents. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  8. Low-dose levodopa therapy in Japanese patients with Parkinson's disease: a retrospective study.

    PubMed

    Kitagawa, Mayumi; Tashiro, Kunio

    2005-09-01

    To investigate the efficacy and the rate of adverse events of chronic low-dose levodopa-carbidopa therapy in Japanese patients with Parkinson's disease (PD). A total of 92 Japanese PD patients treated with low doses of levodopa from the outset were studied. Both disease-specific motor disabilities and quality of life (QOL) in the patients were evaluated using the Unified Parkinson's Disease Rating Scale (UPDRS) and the Parkinson's Disease 39 Quality of Life Questionnaire (PDQ39), respectively. In the overall patient group, the mean duration of treatment, the mean daily dose of levodopa, the disability scores and the motor scores of UPDRS were 6.2 years, 186.4 mg, 8.0 and 19.2, respectively. The rates of motor fluctuations, dyskinesias and hallucinations were 8.7%, 6.5% and 14.1%, respectively. The mean summary index of PDQ39 scores was 23.1. Patients with motor fluctuations showed a significantly earlier disease onset. Dose of levodopa, age at onset, and treatment duration were not associated with the occurrence of dyskinesias. Patients with hallucination had higher doses of levodopa and dopamine agonist. Our results demonstrate that chronic administration of a low-dose levodopa preparation can provide satisfactory benefit with a low incidence of motor complications, and can result in good QOL in Japanese patients with PD. The concomitant use of a small amount of dopamine agonist and amantadine from the outset has partly contributed to a reduced dose of levodopa and the lesser occurrence of motor complications.

  9. Dosimetric considerations and early clinical experience of accelerated partial breast irradiation using multi-lumen applicators in the setting of breast augmentation.

    PubMed

    Akhtari, Mani; Pino, Ramiro; Scarboro, Sarah B; Bass, Barbara L; Miltenburg, Darlene M; Butler, E Brian; Teh, Bin S

    2015-12-01

    Accelerated partial breast irradiation (APBI) is an accepted treatment option in breast-conserving therapy for early stage breast cancer. However, data regarding outcomes of patients treated with multi-lumen catheter systems who have existing breast implants is limited. The purpose of this study was to report treatment parameters, outcomes, and possible dosimetric correlation with cosmetic outcome for this population of patients at our institution. We report the treatment and outcome of seven consecutive patients with existing breast implants and early stage breast cancer who were treated between 2009 and 2013 using APBI following lumpectomy. All patients were treated twice per day for five days to a total dose of 34 Gy using a high-dose-rate (192)Ir source. Cosmetic outcomes were evaluated using the Harvard breast cosmesis scale, and late toxicities were reported using the Radiation Therapy Oncology Group (RTOG) late radiation morbidity schema. After a mean follow-up of 32 months, all patients have remained cancer free. Six out of seven patients had an excellent or good cosmetic outcome. There were no grade 3 or 4 late toxicities. The average total breast implant volume was 279.3 cc, received an average mean dose of 12.1 Gy, and a maximum dose of 234.1 Gy. The average percentage of breast implant volume receiving 50%, 75%, 100%, 150%, and 200% of the prescribed dose was 15.6%, 7.03%, 4.6%, 1.58%, and 0.46%, respectively. Absolute volume of breast implants receiving more than 50% of prescribed dose correlated with worse cosmetic outcomes. Accelerated partial breast irradiation using a multi-lumen applicator in patients with existing breast implants can safely be performed with promising early clinical results. The presence of the implant did not compromise the ability to achieve dosimetric criteria; however, dose to the implant and the irradiated implant volume may be related with worse cosmetic outcomes.

  10. Dosimetric considerations and early clinical experience of accelerated partial breast irradiation using multi-lumen applicators in the setting of breast augmentation

    PubMed Central

    Akhtari, Mani; Pino, Ramiro; Scarboro, Sarah B.; Bass, Barbara L.; Miltenburg, Darlene M.; Butler, E. Brian

    2015-01-01

    Purpose Accelerated partial breast irradiation (APBI) is an accepted treatment option in breast-conserving therapy for early stage breast cancer. However, data regarding outcomes of patients treated with multi-lumen catheter systems who have existing breast implants is limited. The purpose of this study was to report treatment parameters, outcomes, and possible dosimetric correlation with cosmetic outcome for this population of patients at our institution. Material and methods We report the treatment and outcome of seven consecutive patients with existing breast implants and early stage breast cancer who were treated between 2009 and 2013 using APBI following lumpectomy. All patients were treated twice per day for five days to a total dose of 34 Gy using a high-dose-rate 192Ir source. Cosmetic outcomes were evaluated using the Harvard breast cosmesis scale, and late toxicities were reported using the Radiation Therapy Oncology Group (RTOG) late radiation morbidity schema. Results After a mean follow-up of 32 months, all patients have remained cancer free. Six out of seven patients had an excellent or good cosmetic outcome. There were no grade 3 or 4 late toxicities. The average total breast implant volume was 279.3 cc, received an average mean dose of 12.1 Gy, and a maximum dose of 234.1 Gy. The average percentage of breast implant volume receiving 50%, 75%, 100%, 150%, and 200% of the prescribed dose was 15.6%, 7.03%, 4.6%, 1.58%, and 0.46%, respectively. Absolute volume of breast implants receiving more than 50% of prescribed dose correlated with worse cosmetic outcomes. Conclusions Accelerated partial breast irradiation using a multi-lumen applicator in patients with existing breast implants can safely be performed with promising early clinical results. The presence of the implant did not compromise the ability to achieve dosimetric criteria; however, dose to the implant and the irradiated implant volume may be related with worse cosmetic outcomes. PMID:26816499

  11. Role of Surgical Versus Clinical Staging in Chemoradiated FIGO Stage IIB-IVA Cervical Cancer Patients—Acute Toxicity and Treatment Quality of the Uterus-11 Multicenter Phase III Intergroup Trial of the German Radiation Oncology Group and the Gynecologic Cancer Group

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marnitz, Simone, E-mail: simone.marnitz-schulze@uk-koeln.de; Martus, Peter; Köhler, Christhardt

    Purpose: The Uterus-11 trial was designed to evaluate the role of surgical staging in patients with cervical cancer before primary chemoradiation therapy (CRT). The present report provides the toxicity data stratified by the treatment arm and technique. Methods and Materials: A total of 255 patients with carcinoma of the uterine cervix (International Federation of Gynecology and Obstetrics stage IIB-IVA) were randomized to either surgical staging followed by CRT (arm A) or clinical staging followed by CRT (arm B). Patients with para-aortic metastases underwent extended field radiation therapy (RT). Brachytherapy was mandatory. The present report presents the acute therapy-related toxicities stratifiedmore » by treatment arm and radiation technique. Results: A total of 240 patients were eligible (n=121 in arm A; n=119 in arm B). Of the 240 patients, 236 (98.3%) underwent external beam RT with a median total dose of 50.4 Gy. The mean treatment duration was 53 days. Of the patients, 60% underwent intensity modulated RT (IMRT). A total of 234 patients (97.5%) underwent chemotherapy, and 231 (96.3%) underwent brachytherapy, with a median single dose of 6 Gy covering the tumor to a median nominal total dose of 28 Gy. Treatment was well tolerated, with 0% grade ≥3 genitourinary and gastrointestinal toxicity, 6% grade 3 nausea, 3% grade 3 vomiting, and <2% grade 3 diarrhea. More patients after surgical staging experienced grade 2 anemia (54.3% in arm A vs 45.3% in arm B; P=.074) and grade 2 leukocytopenia (41.4% vs 31.6%; P=.56). Of the patients who received IMRT versus a 3-dimensional technique, 65.3% versus 33.7% presented with grade 2 anemia. Grade 3 gastrointestinal and grade 2 bladder toxicity were significantly reduced with the use of IMRT. Conclusions: The incidence and severity of acute therapy-related toxicity compared favorably with those from other randomized trials. Excellent adherence to treatment and treatment quality was achieved compared with patterns of care analyses. Surgical staging led to a doubled number of patients treated with extended field RT. The question of whether surgical staging is beneficial in the context of primary CRT requires further study.« less

  12. Losartan/hydrochlorothiazide combination vs. high-dose losartan in patients with morning hypertension--a prospective, randomized, open-labeled, parallel-group, multicenter trial.

    PubMed

    Ueda, Tamenobu; Kai, Hisashi; Imaizumi, Tsutomu

    2012-07-01

    The treatment of morning hypertension has not been established. We compared the efficacy and safety of a losartan/hydrochlorothiazide (HCTZ) combination and high-dose losartan in patients with morning hypertension. A prospective, randomized, open-labeled, parallel-group, multicenter trial enrolled 216 treated outpatients with morning hypertension evaluated by home blood pressure (BP) self-measurement. Patients were randomly assigned to receive a combination therapy of 50 mg losartan and 12.5 mg HCTZ (n=109) or a high-dose therapy with 100 mg losartan (n=107), each of which were administered once every morning. Primary efficacy end points were morning systolic BP (SBP) level and target BP achievement rate after 3 months of treatment. At baseline, BP levels were similar between the two therapy groups. Morning SBP was reduced from 150.3±10.1 to 131.5±11.5 mm Hg by combination therapy (P<0.001) and from 151.0±9.3 to 142.5±13.6 mm Hg by high-dose therapy (P<0.001). The morning SBP reduction was greater in the combination therapy group than in the high-dose therapy group (P<0.001). Combination therapy decreased evening SBP from 141.6±13.3 to 125.3±13.1 mm Hg (P<0.001), and high-dose therapy decreased evening SBP from 138.9±9.9 to 131.4±13.2 mm Hg (P<0.01). Although both therapies improved target BP achievement rates in the morning and evening (P<0.001 for both), combination therapy increased the achievement rates more than high-dose therapy (P<0.001 and P<0.05, respectively). In clinic measurements, combination therapy was superior to high-dose therapy in reducing SBP and improving the achievement rate (P<0.001 and P<0.01, respectively). Combination therapy decreased urine albumin excretion (P<0.05) whereas high-dose therapy reduced serum uric acid. Both therapies indicated strong adherence and few adverse effects (P<0.001). In conclusion, losartan/HCTZ combination therapy was more effective for controlling morning hypertension and reducing urine albumin than high-dose losartan.

  13. Dose and Fractionation in Radiation Therapy of Curative Intent for Non-Small Cell Lung Cancer: Meta-Analysis of Randomized Trials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramroth, Johanna; Cutter, David J.; Darby, Sarah C.

    Purpose: The optimum dose and fractionation in radiation therapy of curative intent for non-small cell lung cancer remains uncertain. We undertook a published data meta-analysis of randomized trials to examine whether radiation therapy regimens with higher time-corrected biologically equivalent doses resulted in longer survival, either when given alone or when given with chemotherapy. Methods and Materials: Eligible studies were randomized comparisons of 2 or more radiation therapy regimens, with other treatments identical. Median survival ratios were calculated for each comparison and pooled. Results: 3795 patients in 25 randomized comparisons of radiation therapy dose were studied. The median survival ratio, highermore » versus lower corrected dose, was 1.13 (95% confidence interval [CI] 1.04-1.22) when radiation therapy was given alone and 0.83 (95% CI 0.71-0.97) when it was given with concurrent chemotherapy (P for difference=.001). In comparisons of radiation therapy given alone, the survival benefit increased with increasing dose difference between randomized treatment arms (P for trend=.004). The benefit increased with increasing dose in the lower-dose arm (P for trend=.01) without reaching a level beyond which no further survival benefit was achieved. The survival benefit did not differ significantly between randomized comparisons where the higher-dose arm was hyperfractionated and those where it was not. There was heterogeneity in the median survival ratio by geographic region (P<.001), average age at randomization (P<.001), and year trial started (P for trend=.004), but not for proportion of patients with squamous cell carcinoma (P=.2). Conclusions: In trials with concurrent chemotherapy, higher radiation therapy doses resulted in poorer survival, possibly caused, at least in part, by high levels of toxicity. Where radiation therapy was given without chemotherapy, progressively higher radiation therapy doses resulted in progressively longer survival, and no upper dose level was found above which there was no further benefit. These findings support the consideration of further radiation therapy dose escalation trials, making use of modern treatment methods to reduce toxicity.« less

  14. Measurements of the neutron dose equivalent for various radiation qualities, treatment machines and delivery techniques in radiation therapy

    NASA Astrophysics Data System (ADS)

    Hälg, R. A.; Besserer, J.; Boschung, M.; Mayer, S.; Lomax, A. J.; Schneider, U.

    2014-05-01

    In radiation therapy, high energy photon and proton beams cause the production of secondary neutrons. This leads to an unwanted dose contribution, which can be considerable for tissues outside of the target volume regarding the long term health of cancer patients. Due to the high biological effectiveness of neutrons in regards to cancer induction, small neutron doses can be important. This study quantified the neutron doses for different radiation therapy modalities. Most of the reports in the literature used neutron dose measurements free in air or on the surface of phantoms to estimate the amount of neutron dose to the patient. In this study, dose measurements were performed in terms of neutron dose equivalent inside an anthropomorphic phantom. The neutron dose equivalent was determined using track etch detectors as a function of the distance to the isocenter, as well as for radiation sensitive organs. The dose distributions were compared with respect to treatment techniques (3D-conformal, volumetric modulated arc therapy and intensity-modulated radiation therapy for photons; spot scanning and passive scattering for protons), therapy machines (Varian, Elekta and Siemens linear accelerators) and radiation quality (photons and protons). The neutron dose equivalent varied between 0.002 and 3 mSv per treatment gray over all measurements. Only small differences were found when comparing treatment techniques, but substantial differences were observed between the linear accelerator models. The neutron dose equivalent for proton therapy was higher than for photons in general and in particular for double-scattered protons. The overall neutron dose equivalent measured in this study was an order of magnitude lower than the stray dose of a treatment using 6 MV photons, suggesting that the contribution of the secondary neutron dose equivalent to the integral dose of a radiotherapy patient is small.

  15. Measurements of the neutron dose equivalent for various radiation qualities, treatment machines and delivery techniques in radiation therapy.

    PubMed

    Hälg, R A; Besserer, J; Boschung, M; Mayer, S; Lomax, A J; Schneider, U

    2014-05-21

    In radiation therapy, high energy photon and proton beams cause the production of secondary neutrons. This leads to an unwanted dose contribution, which can be considerable for tissues outside of the target volume regarding the long term health of cancer patients. Due to the high biological effectiveness of neutrons in regards to cancer induction, small neutron doses can be important. This study quantified the neutron doses for different radiation therapy modalities. Most of the reports in the literature used neutron dose measurements free in air or on the surface of phantoms to estimate the amount of neutron dose to the patient. In this study, dose measurements were performed in terms of neutron dose equivalent inside an anthropomorphic phantom. The neutron dose equivalent was determined using track etch detectors as a function of the distance to the isocenter, as well as for radiation sensitive organs. The dose distributions were compared with respect to treatment techniques (3D-conformal, volumetric modulated arc therapy and intensity-modulated radiation therapy for photons; spot scanning and passive scattering for protons), therapy machines (Varian, Elekta and Siemens linear accelerators) and radiation quality (photons and protons). The neutron dose equivalent varied between 0.002 and 3 mSv per treatment gray over all measurements. Only small differences were found when comparing treatment techniques, but substantial differences were observed between the linear accelerator models. The neutron dose equivalent for proton therapy was higher than for photons in general and in particular for double-scattered protons. The overall neutron dose equivalent measured in this study was an order of magnitude lower than the stray dose of a treatment using 6 MV photons, suggesting that the contribution of the secondary neutron dose equivalent to the integral dose of a radiotherapy patient is small.

  16. Optimizing insulin secretagogue therapy in patients with type 2 diabetes: a randomized double-blind study with repaglinide.

    PubMed

    Schmitz, Ole; Lund, Sten; Andersen, Per Heden; Jønler, Morten; Pørksen, Nils

    2002-02-01

    Repaglinide, a novel antidiabetic agent that has a rapid onset and short duration of action, was developed for mealtime dosing. The purpose of this pharmacodynamic study was to validate a prandial regimen of repaglinide by comparing meal-related dosing with a regimen in which the same total daily dose was divided into only two doses at morning and evening meals. The study was a double-blind, randomized, parallel-group trial in 19 antidiabetic agent-naive subjects with type 2 diabetes (mean age 58 years, known duration of diabetes 3.5 years, HbA(1c) 7.3%, and BMI 32 kg/m(2)). Patients were randomly assigned to receive repaglinide either before each of the three main meals or before breakfast and before the evening meal. Patients in both groups received the same total daily dose of repaglinide. Twenty-four hour profiles of blood glucose, plasma insulin, and plasma C-peptide concentrations were measured at baseline and after 4 weeks of treatment. Repaglinide increased postprandial insulin levels and markedly reduced postprandial glucose levels relative to baseline in both groups. Significant reductions were also recorded in fasting blood glucose and HbA(1c) levels. The repaglinide regimen, in which a dose was taken before each main meal, was more effective in improving glycemic control (including postprandial glucose and HbA(1c) levels) than the same total dose of repaglinide divided into morning and evening mealtime doses. These data support the strategy of mealtime dosing with repaglinide. The improvements in glycemic control observed in these patients are encouraging. In addition to classic parameters of glycemic control, improvements in postprandial glucose excursions may prove to be important because postprandial hyperglycemia has been suggested to be an independent risk factor for cardiovascular disease in diabetes.

  17. Successful pregnancy following very high-dose total body irradiation (1575 cGy) and bone marrow transplantation in a woman with acute myeloid leukemia.

    PubMed

    Wang, W S; Tzeng, C H; Hsieh, R K; Chiou, T J; Liu, J H; Yen, C C; Chen, P M

    1998-02-01

    A 22-year-old woman had a normal full-term delivery 6 years after a successful allogeneic bone marrow transplantation (BMT) for acute myeloid leukemia (AML). Conditioning therapy consisted of cyclophosphamide (120 mg/kg) and total body irradiation (TBI) to a total of 1575 cGy in seven fractions (225 cGy x 7, at a dose rate of 3.5 cGy/min). Graft-versus-host disease prophylaxis was with methotrexate and cyclosporin A. Grade I acute GVHD developed after BMT but there was no chronic GVHD. She became amenorrhoeic after BMT and serial gonadal testing indicated hypergonadotrophic hypogonadism. She became pregnant and delivered a full-term, healthy baby 6 years after BMT. Successful pregnancy after TBI of more than 1200 cGy is extremely rare. This case, to the best of our knowledge, is the second patient who received a higher dose of TBI (1575 cGy) to have a successful pregnancy. This and previous reports indicate that normal pregnancy is possible after BMT with TBI in excess of 1200 cGy.

  18. Modeling treatment couches in the Pinnacle treatment planning system: Especially important for arc therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duggar, William Neil, E-mail: wduggar@umc.edu; Nguyen, Alex; Stanford, Jason

    This study is to demonstrate the importance and a method of properly modeling the treatment couch for dose calculation in patient treatment using arc therapy. The 2 treatment couch tops—Aktina AK550 and Elekta iBEAM evo—of Elekta LINACs were scanned using Philips Brilliance Big Bore CT Simulator. Various parts of the couch tops were contoured, and their densities were measured and recorded on the Pinnacle treatment planning system (TPS) using the established computed tomography density table. These contours were saved as organ models to be placed beneath the patient during planning. Relative attenuation measurements were performed following procedures outlined by TG-176more » as well as absolute dose comparison of static fields of 10 × 10 cm{sup 2} that were delivered through the couch tops with that calculated in the TPS with the couch models. A total of 10 random arc therapy treatment plans (5 volumetric-modulated arc therapy [VMAT] and 5 stereotactic body radiation therapy [SBRT]), using 24 beams, were selected for this study. All selected plans were calculated with and without couch modeling. Each beam was evaluated using the Delta{sup 4} dosimetry system (Delta{sup 4}). The Student t-test was used to determine statistical significance. Independent reviews were exploited as per the Imaging and Radiation Oncology Core head and neck credentialing phantom. The selected plans were calculated on the actual patient anatomies with and without couch modeling to determine potential clinical effects. Large relative beam attenuations were noted dependent on which part of the couch top beams were passing through. Substantial improvements were also noted for static fields both calculated with the TPS and delivered physically when the couch models were included in the calculation. A statistically significant increase in agreement was noted for dose difference, distance to agreement, and γ-analysis with the Delta{sup 4} on VMAT and SBRT plans. A credentialing review showed improvement in treatment delivery after couch modeling with both thermoluminescent dosimeter doses and film analysis. Furthermore, analysis of treatment plans with and without using the couch model showed a statistically significant reduction in planning target volume coverage and increase in skin dose. In conclusion, ignoring the treatment couch, a common practice when generating a patient treatment plan, can overestimate the dose delivered especially for arc therapy. This work shows that explicitly modeling the couch during planning can meaningfully improve the agreement between calculated and measured dose distributions. Because of this project, we have implemented the couch models clinically across all treatment plans.« less

  19. SU-E-T-216: Comparison of Volumetrically Modulated Arc Therapy Treatment Using Flattening Filter Free Beams Vs. Flattened Beams for Partial Brain Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, S; Roa, D; Hanna, N

    2015-06-15

    Purpose: Flattening Filter Free (FFF) beams offer the potential for higher dose rates, short treatment time, and lower out of field dose. Therefore, the aim of this study was to investigate the dosimetric effects and out of field dose of Volumetric Modulated Arc Therapy (VMAT) plans using FFF vs Flattening Filtering (FF) beams for partial brain irradiation. Methods: Ten brain patients treated with a 6FF beam from a Truebeam STX were analyzed retrospectively for this study. These plans (46Gy at 2 Gy per fraction) were re-optimized for 6FFF beams using the same dose constraints as the original plans. PTV coverage,more » PTV Dmax, total MUs, and mean dose to organs-at-risk (OAR) were evaluated. In addition, the out-of-field dose for 6FF and 6FFF plans for one patient was measured on an anthropomorphic phantom. TLDs were placed inside (central axis) and outside (surface) the phantom at distances ranging from 0.5 cm to 17 cm from the field edge. Paired T-test was used for statistical analysis. Results: PTV coverage and PTV Dmax were comparable for the FF and FFF plans with 95.9% versus 95.6% and 111.2% versus 111.9%, respectively. Mean dose to the OARs were 3.7% less for FFF than FF plans (p<0.0001). Total MUs were, on average, 12.5% greater for FFF than FF plans with 481±55 MU (FFF) versus 429±50 MU (FF), p=0.0003. On average, the measured out of field dose was 24% less for FFF compared to FF, p<0.0001. A similar beam-on time was observed for the FFF and FF treatment. Conclusion: It is beneficial to use 6FFF beams for regular fractionated brain VMAT treatments. VMAT treatment plans using FFF beams can achieve comparable PTV coverage but with more OAR sparing. The out of field dose is significant less with mean reduction of 24%.« less

  20. Optimization of Treatment Geometry to Reduce Normal Brain Dose in Radiosurgery of Multiple Brain Metastases with Single-Isocenter Volumetric Modulated Arc Therapy.

    PubMed

    Wu, Qixue; Snyder, Karen Chin; Liu, Chang; Huang, Yimei; Zhao, Bo; Chetty, Indrin J; Wen, Ning

    2016-09-30

    Treatment of patients with multiple brain metastases using a single-isocenter volumetric modulated arc therapy (VMAT) has been shown to decrease treatment time with the tradeoff of larger low dose to the normal brain tissue. We have developed an efficient Projection Summing Optimization Algorithm to optimize the treatment geometry in order to reduce dose to normal brain tissue for radiosurgery of multiple metastases with single-isocenter VMAT. The algorithm: (a) measures coordinates of outer boundary points of each lesion to be treated using the Eclipse Scripting Application Programming Interface, (b) determines the rotations of couch, collimator, and gantry using three matrices about the cardinal axes, (c) projects the outer boundary points of the lesion on to Beam Eye View projection plane, (d) optimizes couch and collimator angles by selecting the least total unblocked area for each specific treatment arc, and (e) generates a treatment plan with the optimized angles. The results showed significant reduction in the mean dose and low dose volume to normal brain, while maintaining the similar treatment plan qualities on the thirteen patients treated previously. The algorithm has the flexibility with regard to the beam arrangements and can be integrated in the treatment planning system for clinical application directly.

  1. Pharmacokinetics, pharmacodynamics, and pharmacogenetics of hydroxyurea treatment for children with sickle cell anemia

    PubMed Central

    Despotovic, Jenny M.; Mortier, Nicole A.; Flanagan, Jonathan M.; He, Jin; Smeltzer, Matthew P.; Kimble, Amy C.; Aygun, Banu; Wu, Song; Howard, Thad; Sparreboom, Alex

    2011-01-01

    Hydroxyurea therapy has proven laboratory and clinical efficacies for children with sickle cell anemia (SCA). When administered at maximum tolerated dose (MTD), hydroxyurea increases fetal hemoglobin (HbF) to levels ranging from 10% to 40%. However, interpatient variability of percentage of HbF (%HbF) response is high, MTD itself is variable, and accurate predictors of hydroxyurea responses do not currently exist. HUSTLE (NCT00305175) was designed to provide first-dose pharmacokinetics (PK) data for children with SCA initiating hydroxyurea therapy, to investigate pharmacodynamics (PD) parameters, including HbF response and MTD after standardized dose escalation, and to evaluate pharmacogenetics influences on PK and PD parameters. For 87 children with first-dose PK studies, substantial interpatient variability was observed, plus a novel oral absorption phenotype (rapid or slow) that influenced serum hydroxyurea levels and total hydroxyurea exposure. PD responses in 174 subjects were robust and similar to previous cohorts; %HbF at MTD was best predicted by 5 variables, including baseline %HbF, whereas MTD was best predicted by 5 variables, including serum creatinine. Pharmacogenetics analysis showed single nucleotide polymorphisms influencing baseline %HbF, including 5 within BCL11A, but none influencing MTD %HbF or dose. Accurate prediction of hydroxyurea treatment responses for SCA remains a worthy but elusive goal. PMID:21876119

  2. [Continued Use of Rotigotine Transdermal Patches for Parkinson Disease].

    PubMed

    Yasutaka, Yuki; Fujioka, Shinsuke; Shibaguchi, Hirotomo; Imakyure, Osamu; Washiyama, Atsushi; Tsuboi, Yoshio; Futagami, Koujiro

    2016-06-01

    Transdermal patches containing rotigotine, a dopamine agonist (DA) for treatment of Parkinson disease, continuously exert stable effects when applied once daily. Therefore, they are expected to reduce the patient burdens due to complications such as wearing-off and dysphagia. However, dosing is occasionally reduced or discontinued after application because of several reasons such as skin reactions or unsatisfactory efficacy. To identify the risk factors involved in the reduced or discontinued use of rotigotine patches, a retrospective study was conducted with reference to the medical records of patients with Parkinson disease who received rotigotine patches in our hospital. 85 patients were involved in this study. Dosing of rotigotine was reduced or discontinued in 53 patients during the study period. The factors associated with charges in treatment included combination therapy with clonazepam and oral administration of another DA before the application of rotigotine. The reduction or discontinuation rate of rotigotine patches in patients who reduced the equivalent dose of DA on the introduction of rotigotine patches was 94.7%, showing a significantly higher rate compared with 61.3% in the increased dose group. To improve adherence to rotigotine patch therapy, physicians need to carefully consider concomitant drugs and total dose of DAs. (Received December 7, 2015; Accepted February 22, 2016; Published June 1, 2016).

  3. 'Real-life' study of imatinib therapy in chronic phase-chronic myeloid leukemia: A novel retrospective observational longitudinal analysis.

    PubMed

    Merante, Serena; Ferretti, Virginia; Elena, Chiara; Calvello, Celeste; Rocca, Barbara; Zappatore, Rita; Cavigliano, Paola; Orlandi, Ester

    2017-01-01

    Imatinib is a cornerstone of treatment of chronic myeloid leukemia. It remains unclear whether transient treatment discontinuation or dose changes affect outcome and this approach has not yet been approved for use outside clinical trials. We conducted a retrospective single-institution observational study to evaluate factors affecting response in 'real-life' clinical practice in 138 chronic myeloid leukemia patients in chronic phase treated with imatinib. We used a novel longitudinal data analytical model, with a generalized estimating equation model, to study BCR-ABL variation according to continuous standard dose, change in dose or discontinuation; BCR-ABL transcript levels were recorded. Treatment history was subdivided into time periods for which treatment was given at constant dosage (total 483 time periods). Molecular and cytogenetic complete response was observed after 154 (32%) and 358 (74%) time periods, respectively. After adjusting for length of time period, no association between dose and cytogenetic complete response rate was observed. There was a significantly lower molecular complete response rate after time periods at a high imatinib dosage. This statistical approach can identify individual patient variation in longitudinal data collected over time and suggests that changes in dose or discontinuation of therapy could be considered in patients with appropriate biological characteristics.

  4. Ipilimumab-induced colitis in patients with metastatic melanoma.

    PubMed

    De Felice, Kara M; Gupta, Arjun; Rakshit, Sagar; Khanna, Sahil; Kottschade, Lisa A; Finnes, Heidi D; Papadakis, Konstantinos A; Loftus, Edward V; Raffals, Laura E; Markovic, Svetomir N

    2015-08-01

    Ipilimumab is used for the treatment of metastatic melanoma and is associated with serious immune-related colitis. We aimed to report the clinical features, treatment, and outcomes of patients with ipilimumab-induced colitis. In this retrospective observational study, we identified patients with unresectable melanoma treated with ipilimumab between March 2011 and September 2013. Diarrhea was assessed using the Common Terminology Criteria for Adverse Events, v3.0. Colitis was defined by diarrhea (grade≥2) requiring steroids with or without endoscopic/histologic/radiologic evidence of colitis. A total of 103 patients with metastatic melanoma treated with ipilimumab were identified. Of these, 30 patients (29%) developed diarrhea (all grades), and 23 patients (22%) developed colitis requiring systemic corticosteroid therapy. The median number of ipilimumab doses before onset of diarrhea was 2 (range, 1-4). Six of 23 patients responded to less than 1 mg/kg daily prednisone alone. Fifteen patients required high-dose oral and/or intravenous prednisone (1-2 mg/kg body weight). Six patients had diarrhea refractory to prednisone; five required rescue therapy with budesonide (9-12 mg daily) and one was treated with infliximab (5 mg/kg, three doses). There was one case of severe diarrhea (grade 3) treated successfully with high-dose budesonide (12 mg) monotherapy. Ipilimumab-induced colitis requires early and aggressive medical therapy. Most patients can be successfully managed with systemic corticosteroids. High-dose budesonide is an attractive steroid-sparing agent, however further studies of its efficacy in this setting are needed. Infliximab should be used in refractory cases to avoid colectomy. Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved.

  5. Intensity-modulated proton therapy for elective nodal irradiation and involved-field radiation in the definitive treatment of locally advanced non-small-cell lung cancer: a dosimetric study.

    PubMed

    Kesarwala, Aparna H; Ko, Christine J; Ning, Holly; Xanthopoulos, Eric; Haglund, Karl E; O'Meara, William P; Simone, Charles B; Rengan, Ramesh

    2015-05-01

    Photon involved-field (IF) radiation therapy (IFRT), the standard for locally advanced (LA) non-small cell lung cancer (NSCLC), results in favorable outcomes without increased isolated nodal failures, perhaps from scattered dose to elective nodal stations. Because of the high conformality of intensity-modulated proton therapy (IMPT), proton IFRT could increase nodal failures. We investigated the feasibility of IMPT for elective nodal irradiation (ENI) in LA-NSCLC. IMPT IFRT plans were generated to the same total dose of 66.6-72 Gy received by 20 LA-NSCLC patients treated with photon IFRT. IMPT ENI plans were generated to 46 cobalt Gray equivalent (CGE) to elective nodal planning treatment volumes (PTV) plus 24 CGE to IF-PTVs. Proton IFRT and ENI improved the IF-PTV percentage of volume receiving 95% of the prescribed dose (D95) by 4% (P < .01) compared with photon IFRT. All evaluated dosimetric parameters improved significantly with both proton plans. The lung percentage of volume receiving 20 Gy/CGE (V20) and mean lung dose decreased 18% (P < .01) and 36% (P < .01), respectively, with proton IFRT, and 11% (P = .03) and 26% (P < .01) with ENI. The mean esophagus dose decreased 16% with IFRT and 12% with ENI; heart V25 decreased 63% with both (all P < .01). This study demonstrates the feasibility of IMPT for LA-NSCLC ENI. Potential decreased toxicity indicates that IMPT could allow ENI while maintaining a favorable therapeutic ratio compared with photon IFRT. Published by Elsevier Inc.

  6. Simultaneous integrated boost with intensity modulated radiation therapy in brain oligometastases: A feasible technique for developing countries

    PubMed Central

    Tiwari, Vivek; Pande, Subodh C.; Verma, Kamal; Goel, Sandeep

    2015-01-01

    Introduction: To analyze the pattern of brain metastasis (BM), and to use intensity modulated radiation therapy (IMRT) for target dose escalation in cases with ≤3 metastatic lesions (oligometastases). Materials and Methods: Thirty-two consecutive cases of BM treated during September 2009 to August 2012 were analyzed retrospectively. Results: The study comprised 13 males (40.62%) and 19 females (59.37%). Thirteen (40%) patients presented with disseminated intracranial metastases, while 19 (60%) had ≤3 foci. In 25 cases (78%), the primary was located either in the breast (14 cases) or lung (11 cases). The 13 patients with disseminated intracranial metastases received whole brain radiation therapy to a dose of 30 Gy/10-12 daily fractions (Group A) while the 19 cases with ≤3 lesions received an additional dose of 6-10 Gy to gross lesions using a simultaneous integrated boost (SIB) with IMRT thus receiving a total dose of 36-40 Gy/12-15 fractions (Group B). Overall survival (OS) for the breast primary was 6.3 and lung primary was 5.3 months, respectively. The mean OS for breast cases in Group B was higher (9.5 months) as compared to Group A cases (1.9 months) and was statistically significant (P = 0.0056). Similarly, primary lung cancer cases in Group B showed a mean OS of 8.75 months versus 2.6 months for Group A cases (P = 0.213). Conclusions: IMRT is a safe and effective technique in cases with oligometastases for dose escalation in the form of SIB. PMID:25839012

  7. Candida albicans gastrointestinal colonization and invasion in the mouse: effect of antibacterial dosing, antifungal therapy and immunosuppression.

    PubMed

    Kinsman, O S; Pitblado, K

    1989-12-01

    Infant mice infected with Candida albicans by the oral-intragastric route became colonized in the gut and were persistently colonized into adulthood. Faecal levels of Candida were correlated with total gastrointestinal Candida and provided a useful means of detecting yeast overgrowth or elimination. Antibacterial agents promoting Candida overgrowth when given by the oral or parenteral route included ceftriaxone, augmentin and cefoperazone. Ceftizoxime had less effect. Ceftazidime and latamoxef produced raised levels only by the oral route. Gentamicin, vancomycin and metronidazole did not affect the Candida levels. Dosing with some antibacterials promoted an increase in gastrointestinal Candida and invasion to a greater extent than immunosuppression. Antifungal therapy to reduce gastrointestinal colonization was investigated using amphotericin B, nystatin, ketoconazole, intraconazole and fluconazole. Fluconazole was most effective at reducing faecal Candida.

  8. The Effect of Intra-articular Corticosteroids on Articular Cartilage

    PubMed Central

    Wernecke, Chloe; Braun, Hillary J.; Dragoo, Jason L.

    2015-01-01

    Background: Intra-articular (IA) corticosteroid therapy has been used for the treatment of inflammation and pain in the knee since the 1950s. Purpose: To review the current literature on the effects of IA corticosteroids on articular cartilage. Study Design: Systematic review. Methods: A MEDLINE and SCOPUS database search was performed, and studies were selected for basic science and clinical trial research on corticosteroids with direct outcome measures of cartilage health. Preliminary searches yielded 1929 articles, and final analysis includes 40 studies. Results: Methylprednisolone, dexamethasone, hydrocortisone, betamethasone, prednisolone, and triamcinolone were reported to display dose-dependent deleterious effects on cartilage morphology, histology, and viability in both in vitro and in vivo models. The beneficial animal in vivo effects of methylprednisolone, hydrocortisone, and triamcinolone occurred at low doses (usually <2-3 mg/dose or 8-12 mg/cumulative total dose in vivo), at which increased cell growth and recovery from damage was observed; the single human clinical trial indicated a beneficial effect of triamcinolone. However, at higher doses (>3 mg/dose or 18-24 mg/cumulative total dose in vivo), corticosteroids were associated with significant gross cartilage damage and chondrocyte toxicity. Dose and time dependency of corticosteroid chondrotoxicity was supported in the in vitro results, however, without clear dose thresholds. Conclusion: Corticosteroids have a time- and dose-dependent effect on articular cartilage, with beneficial effects occurring at low doses and durations and detrimental effects at high doses and durations. Clinically, beneficial effects are supported for IA administration, but the lowest efficacious dose should be used. PMID:26674652

  9. Clinical Outcomes Among Children With Standard-Risk Medulloblastoma Treated With Proton and Photon Radiation Therapy: A Comparison of Disease Control and Overall Survival

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eaton, Bree R.; Esiashvili, Natia; Kim, Sungjin

    Purpose: The purpose of this study was to compare long-term disease control and overall survival between children treated with proton and photon radiation therapy (RT) for standard-risk medulloblastoma. Methods and Materials: This multi-institution cohort study includes 88 children treated with chemotherapy and proton (n=45) or photon (n=43) RT between 2000 and 2009. Overall survival (OS), recurrence-free survival (RFS), and patterns of failure were compared between the 2 cohorts. Results: Median (range) age was 6 years old at diagnosis (3-21 years) for proton patients versus 8 years (3-19 years) for photon patients (P=.011). Cohorts were similar with respect to sex, histology, extent of surgical resection,more » craniospinal irradiation (CSI) RT dose, total RT dose, whether the RT boost was delivered to the posterior fossa (PF) or tumor bed (TB), time from surgery to RT start, or total duration of RT. RT consisted of a median (range) CSI dose of 23.4 Gy (18-27 Gy) and a boost of 30.6 Gy (27-37.8 Gy). Median follow-up time is 6.2 years (95% confidence interval [CI]: 5.1-6.6 years) for proton patients versus 7.0 years (95% CI: 5.8-8.9 years) for photon patients. There was no significant difference in RFS or OS between patients treated with proton versus photon RT; 6-year RFS was 78.8% versus 76.5% (P=.948) and 6-year OS was 82.0% versus 87.6%, respectively (P=.285). On multivariate analysis, there was a trend for longer RFS with females (P=.058) and higher CSI dose (P=.096) and for longer OS with females (P=.093). Patterns of failure were similar between the 2 cohorts (P=.908). Conclusions: Disease control with proton and photon radiation therapy appears equivalent for standard risk medulloblastoma.« less

  10. Neutropenia induced by high-dose intravenous benzylpenicillin in treating neurosyphilis: Does it really matter?

    PubMed Central

    Zhao, Wei; Qi, Tengfei; Shi, Mei; Guan, Zhifang; Lu, Haikong; Long, Fuquan; Gao, Zixiao; Zhang, Sufang; Zhou, Pingyu

    2017-01-01

    Background Prompt therapy with high-dose intravenous benzylpenicillin for a prolonged period is critical for neurosyphilis patients to avoid irreversible sequelae. However, life-threatening neutropenia has been reported as a complication of prolonged therapy with high doses of benzylpenicillin when treating other diseases. This study aimed to investigate the incidence, presentation, management and prognosis of benzylpenicillin-induced neutropenia in treating neurosyphilis based on a large sample of syphilis patients in Shanghai. Methodology/Principal findings Between 1st January 2013 and 31st December 2015, 1367 patients with neurosyphilis were treated with benzylpenicillin, 578 of whom were eligible for recruitment to this study. Among patients without medical co-morbidities, the total incidence of benzylpenicillin-induced neutropenia and severe neutropenia was 2.42% (95% CI: 1.38–4.13%) and 0.35% (95% CI: 0.06–1.39%), respectively. The treatment duration before onset of neutropenia ranged from 10 to 14 days, with a total cumulative dose of between 240 and 324 megaunits of benzylpenicillin. Neutropenia was accompanied by symptoms of chills and fever (5 patients), fatigue (2 patients), cough (1 patient), sore throat (1 patient), diarrhea (1 patient) and erythematous rash (1 patient). The severity of neutropenia was not associated with age, gender or type of neurosyphilis (p>0.05). Neutropenia, even when severe, was often tolerated and normalized within one week. A more serious neutropenia did not occur when reinstituting benzylpenicillin in patients with mild or moderate neutropenia nor when ceftriaxone was used three months after patients had previously experienced severe neutropenia. Conclusions/Significance Benzylpenicillin-induced neutropenia was uncommon in our cohort of patients. Continuation of therapy was possible with intensive surveillance for those with mild or moderate neutropenia. For severe neutropenia, it is not essential to aggressively use hematopoietic growth factors or broad-spectrum antibiotics for patients in good physical condition after withdrawing anti-neurosyphilis regimen. We did not see an exacerbation of neutropenia in patients with the readministration of benzylpenicillin. PMID:28288165

  11. Neutropenia induced by high-dose intravenous benzylpenicillin in treating neurosyphilis: Does it really matter?

    PubMed

    Peng, Rui-Rui; Wu, Juan; Zhao, Wei; Qi, Tengfei; Shi, Mei; Guan, Zhifang; Lu, Haikong; Long, Fuquan; Gao, Zixiao; Zhang, Sufang; Zhou, Pingyu

    2017-03-01

    Prompt therapy with high-dose intravenous benzylpenicillin for a prolonged period is critical for neurosyphilis patients to avoid irreversible sequelae. However, life-threatening neutropenia has been reported as a complication of prolonged therapy with high doses of benzylpenicillin when treating other diseases. This study aimed to investigate the incidence, presentation, management and prognosis of benzylpenicillin-induced neutropenia in treating neurosyphilis based on a large sample of syphilis patients in Shanghai. Between 1st January 2013 and 31st December 2015, 1367 patients with neurosyphilis were treated with benzylpenicillin, 578 of whom were eligible for recruitment to this study. Among patients without medical co-morbidities, the total incidence of benzylpenicillin-induced neutropenia and severe neutropenia was 2.42% (95% CI: 1.38-4.13%) and 0.35% (95% CI: 0.06-1.39%), respectively. The treatment duration before onset of neutropenia ranged from 10 to 14 days, with a total cumulative dose of between 240 and 324 megaunits of benzylpenicillin. Neutropenia was accompanied by symptoms of chills and fever (5 patients), fatigue (2 patients), cough (1 patient), sore throat (1 patient), diarrhea (1 patient) and erythematous rash (1 patient). The severity of neutropenia was not associated with age, gender or type of neurosyphilis (p>0.05). Neutropenia, even when severe, was often tolerated and normalized within one week. A more serious neutropenia did not occur when reinstituting benzylpenicillin in patients with mild or moderate neutropenia nor when ceftriaxone was used three months after patients had previously experienced severe neutropenia. Benzylpenicillin-induced neutropenia was uncommon in our cohort of patients. Continuation of therapy was possible with intensive surveillance for those with mild or moderate neutropenia. For severe neutropenia, it is not essential to aggressively use hematopoietic growth factors or broad-spectrum antibiotics for patients in good physical condition after withdrawing anti-neurosyphilis regimen. We did not see an exacerbation of neutropenia in patients with the readministration of benzylpenicillin.

  12. Macrolide therapy is associated with reduced mortality in acute respiratory distress syndrome (ARDS) patients.

    PubMed

    Simonis, Fabienne D; de Iudicibus, Gianfranco; Cremer, Olaf L; Ong, David S Y; van der Poll, Tom; Bos, Lieuwe D; Schultz, Marcus J

    2018-01-01

    Macrolides have been associated with favorable immunological effects in various inflammatory disease states. We investigated the association between macrolide therapy and mortality in patients with the acute respiratory distress syndrome (ARDS). This was an unplanned secondary analysis of patients with ARDS within a large prospective observational study of critically ill patients in the intensive care units (ICUs) of two university-affiliated hospitals in the Netherlands. The exposure of interest was low-dose macrolide use prescribed for another reason than infection; we excluded patients who received high-dose macrolides for an infection. The primary endpoint was 30-day mortality. The association between macrolide therapy and mortality was determined in the whole cohort, as well as in a propensity score matched cohort; the association was compared between pulmonary versus non-pulmonary ARDS, and between two biological phenotypes based on plasma levels of 20 biomarkers. In total, 873 patients with ARDS were analyzed, of whom 158 patients (18%) received macrolide therapy during stay in ICU for a median duration of 3 (interquartile range, 1-4) days. Erythromycin was the most frequent prescribed macrolide (97%). Macrolide therapy was associated with reduced 30-day mortality in the whole cohort [22.8% vs. 31.6%; crude odds ratio (OR), 0.64 (interquartile range, 0.43-0.96), P=0.03]. The association in the propensity score matched cohort remained significant [22.8% vs. 32.9%; OR, 0.62 (interquartile range, 0.39-0.96), P=0.03]. Propensity matched associations with mortality were different in patients with non-pulmonary ARDS vs. pulmonary ARDS and also varied by biological phenotype. These data together show that low-dose macrolide therapy prescribed for another reason than infection is associated with decreased mortality in patients with ARDS.

  13. Macrolide therapy is associated with reduced mortality in acute respiratory distress syndrome (ARDS) patients

    PubMed Central

    de Iudicibus, Gianfranco; Cremer, Olaf L.; Ong, David S. Y.; van der Poll, Tom; Bos, Lieuwe D.; Schultz, Marcus J.

    2018-01-01

    Background Macrolides have been associated with favorable immunological effects in various inflammatory disease states. We investigated the association between macrolide therapy and mortality in patients with the acute respiratory distress syndrome (ARDS). Methods This was an unplanned secondary analysis of patients with ARDS within a large prospective observational study of critically ill patients in the intensive care units (ICUs) of two university-affiliated hospitals in the Netherlands. The exposure of interest was low-dose macrolide use prescribed for another reason than infection; we excluded patients who received high-dose macrolides for an infection. The primary endpoint was 30-day mortality. The association between macrolide therapy and mortality was determined in the whole cohort, as well as in a propensity score matched cohort; the association was compared between pulmonary versus non-pulmonary ARDS, and between two biological phenotypes based on plasma levels of 20 biomarkers. Results In total, 873 patients with ARDS were analyzed, of whom 158 patients (18%) received macrolide therapy during stay in ICU for a median duration of 3 (interquartile range, 1–4) days. Erythromycin was the most frequent prescribed macrolide (97%). Macrolide therapy was associated with reduced 30-day mortality in the whole cohort [22.8% vs. 31.6%; crude odds ratio (OR), 0.64 (interquartile range, 0.43–0.96), P=0.03]. The association in the propensity score matched cohort remained significant [22.8% vs. 32.9%; OR, 0.62 (interquartile range, 0.39–0.96), P=0.03]. Propensity matched associations with mortality were different in patients with non-pulmonary ARDS vs. pulmonary ARDS and also varied by biological phenotype. Conclusions These data together show that low-dose macrolide therapy prescribed for another reason than infection is associated with decreased mortality in patients with ARDS. PMID:29430441

  14. The Safety, Effectiveness and Concentrations of Adjusted Lopinavir/Ritonavir in HIV-Infected Adults on Rifampicin-Based Antitubercular Therapy

    PubMed Central

    Decloedt, Eric H.; Maartens, Gary; Smith, Peter; Merry, Concepta; Bango, Funeka; McIlleron, Helen

    2012-01-01

    Objective Rifampicin co-administration dramatically reduces plasma lopinavir concentrations. Studies in healthy volunteers and HIV-infected patients showed that doubling the dose of lopinavir/ritonavir (LPV/r) or adding additional ritonavir offsets this interaction. However, high rates of hepatotoxicity were observed in healthy volunteers. We evaluated the safety, effectiveness and pre-dose concentrations of adjusted doses of LPV/r in HIV infected adults treated with rifampicin-based tuberculosis treatment. Methods Adult patients on a LPV/r-based antiretroviral regimen and rifampicin-based tuberculosis therapy were enrolled. Doubled doses of LPV/r or an additional 300 mg of ritonavir were used to overcome the inducing effect of rifampicin. Steady-state lopinavir pre-dose concentrations were evaluated every second month. Results 18 patients were enrolled with a total of 79 patient months of observation. 11/18 patients were followed up until tuberculosis treatment completion. During tuberculosis treatment, the median (IQR) pre-dose lopinavir concentration was 6.8 (1.1–9.2) mg/L and 36/47 (77%) were above the recommended trough concentration of 1 mg/L. Treatment was generally well tolerated with no grade 3 or 4 toxicity: 8 patients developed grade 1 or 2 transaminase elevation, 1 patient defaulted additional ritonavir due to nausea and 1 patient developed diarrhea requiring dose reduction. Viral loads after tuberculosis treatment were available for 11 patients and 10 were undetectable. Conclusion Once established on treatment, adjusted doses of LPV/r co-administered with rifampicin-based tuberculosis treatment were tolerated and LPV pre-dose concentrations were adequate. PMID:22412856

  15. Geant4 beam model for boron neutron capture therapy: investigation of neutron dose components.

    PubMed

    Moghaddasi, Leyla; Bezak, Eva

    2018-03-01

    Boron neutron capture therapy (BNCT) is a biochemically-targeted type of radiotherapy, selectively delivering localized dose to tumour cells diffused in normal tissue, while minimizing normal tissue toxicity. BNCT is based on thermal neutron capture by stable [Formula: see text]B nuclei resulting in emission of short-ranged alpha particles and recoil [Formula: see text]Li nuclei. The purpose of the current work was to develop and validate a Monte Carlo BNCT beam model and to investigate contribution of individual dose components resulting of neutron interactions. A neutron beam model was developed in Geant4 and validated against published data. The neutron beam spectrum, obtained from literature for a cyclotron-produced beam, was irradiated to a water phantom with boron concentrations of 100 μg/g. The calculated percentage depth dose curves (PDDs) in the phantom were compared with published data to validate the beam model in terms of total and boron depth dose deposition. Subsequently, two sensitivity studies were conducted to quantify the impact of: (1) neutron beam spectrum, and (2) various boron concentrations on the boron dose component. Good agreement was achieved between the calculated and measured neutron beam PDDs (within 1%). The resulting boron depth dose deposition was also in agreement with measured data. The sensitivity study of several boron concentrations showed that the calculated boron dose gradually converged beyond 100 μg/g boron concentration. This results suggest that 100μg/g tumour boron concentration may be optimal and above this value limited increase in boron dose is expected for a given neutron flux.

  16. Phase 1 Dose Escalation Study of Accelerated Radiation Therapy With Concurrent Chemotherapy for Locally Advanced Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelsey, Chris R., E-mail: christopher.kelsey@duke.edu; Das, Shiva; Gu, Lin

    2015-12-01

    Purpose: To determine the maximum tolerated dose of radiation therapy (RT) given in an accelerated fashion with concurrent chemotherapy using intensity modulated RT. Methods and Materials: Patients with locally advanced lung cancer (non-small cell and small cell) with good performance status and minimal weight loss received concurrent cisplatin and etoposide with RT. Intensity modulated RT with daily image guidance was used to facilitate esophageal avoidance and delivered using 6 fractions per week (twice daily on Fridays with a 6-hour interval). The dose was escalated from 58 Gy to a planned maximum dose of 74 Gy in 4 Gy increments in a standardmore » 3 + 3 trial design. Dose-limiting toxicity (DLT) was defined as acute grade 3-5 nonhematologic toxicity attributed to RT. Results: A total of 24 patients were enrolled, filling all dose cohorts, all completing RT and chemotherapy as prescribed. Dose-limiting toxicity occurred in 1 patient at 58 Gy (grade 3 esophagitis) and 1 patient at 70 Gy (grade 3 esophageal fistula). Both patients with DLTs had large tumors (12 cm and 10 cm, respectively) adjacent to the esophagus. Three additional patients were enrolled at both dose cohorts without further DLT. In the final 74-Gy cohort, no DLTs were observed (0 of 6). Conclusions: Dose escalation and acceleration to 74 Gy with intensity modulated RT and concurrent chemotherapy was tolerable, with a low rate of grade ≥3 acute esophageal reactions.« less

  17. Real-time in vivo rectal wall dosimetry using plastic scintillation detectors for patients with prostate cancer

    PubMed Central

    Wootton, Landon; Kudchadker, Rajat; Lee, Andrew; Beddar, Sam

    2014-01-01

    We designed and constructed an in vivo dosimetry system using plastic scintillation detectors (PSDs) to monitor dose to the rectal wall in patients undergoing intensity-modulated radiation therapy for prostate cancer. Five patients were enrolled in an Institutional Review Board–approved protocol for twice weekly in vivo dose monitoring with our system, resulting in a total of 142 in vivo dose measurements. PSDs were attached to the surface of endorectal balloons used for prostate immobilization to place the PSDs in contact with the rectal wall. Absorbed dose was measured in real time and the total measured dose was compared with the dose calculated by the treatment planning system on the daily CT image dataset. The mean difference between measured and calculated doses for the entire patient population was −0.4% (standard deviation 2.8%). The mean difference between daily measured and calculated doses for each patient ranged from −3.3% to 3.3% (standard deviation ranged from 5.6% to 7.1% for 4 patients and was 14.0% for the last, for whom optimal positioning of the detector was difficult owing to the patient’s large size). Patients tolerated the detectors well and the treatment workflow was not compromised. Overall, PSDs performed well as in vivo dosimeters, providing excellent accuracy, real-time measurement, and reusability. PMID:24434775

  18. Real-time in vivo rectal wall dosimetry using plastic scintillation detectors for patients with prostate cancer

    NASA Astrophysics Data System (ADS)

    Wootton, Landon; Kudchadker, Rajat; Lee, Andrew; Beddar, Sam

    2014-02-01

    We designed and constructed an in vivo dosimetry system using plastic scintillation detectors (PSDs) to monitor dose to the rectal wall in patients undergoing intensity-modulated radiation therapy for prostate cancer. Five patients were enrolled in an Institutional Review Board-approved protocol for twice weekly in vivo dose monitoring with our system, resulting in a total of 142 in vivo dose measurements. PSDs were attached to the surface of endorectal balloons used for prostate immobilization to place the PSDs in contact with the rectal wall. Absorbed dose was measured in real time and the total measured dose was compared with the dose calculated by the treatment planning system on the daily computed tomographic image dataset. The mean difference between measured and calculated doses for the entire patient population was -0.4% (standard deviation 2.8%). The mean difference between daily measured and calculated doses for each patient ranged from -3.3% to 3.3% (standard deviation ranged from 5.6% to 7.1% for four patients and was 14.0% for the last, for whom optimal positioning of the detector was difficult owing to the patient's large size). Patients tolerated the detectors well and the treatment workflow was not compromised. Overall, PSDs performed well as in vivo dosimeters, providing excellent accuracy, real-time measurement and reusability.

  19. Water and tissue equivalence of a new PRESAGE{sup Registered-Sign} formulation for 3D proton beam dosimetry: A Monte Carlo study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gorjiara, Tina; Kuncic, Zdenka; Doran, Simon

    2012-11-15

    Purpose: To evaluate the water and tissue equivalence of a new PRESAGE{sup Registered-Sign} 3D dosimeter for proton therapy. Methods: The GEANT4 software toolkit was used to calculate and compare total dose delivered by a proton beam with mean energy 62 MeV in a PRESAGE{sup Registered-Sign} dosimeter, water, and soft tissue. The dose delivered by primary protons and secondary particles was calculated. Depth-dose profiles and isodose contours of deposited energy were compared for the materials of interest. Results: The proton beam range was found to be Almost-Equal-To 27 mm for PRESAGE{sup Registered-Sign }, 29.9 mm for soft tissue, and 30.5 mmmore » for water. This can be attributed to the lower collisional stopping power of water compared to soft tissue and PRESAGE{sup Registered-Sign }. The difference between total dose delivered in PRESAGE{sup Registered-Sign} and total dose delivered in water or tissue is less than 2% across the entire water/tissue equivalent range of the proton beam. The largest difference between total dose in PRESAGE{sup Registered-Sign} and total dose in water is 1.4%, while for soft tissue it is 1.8%. In both cases, this occurs at the distal end of the beam. Nevertheless, the authors find that PRESAGE{sup Registered-Sign} dosimeter is overall more tissue-equivalent than water-equivalent before the Bragg peak. After the Bragg peak, the differences in the depth doses are found to be due to differences in primary proton energy deposition; PRESAGE{sup Registered-Sign} and soft tissue stop protons more rapidly than water. The dose delivered by secondary electrons in the PRESAGE{sup Registered-Sign} differs by less than 1% from that in soft tissue and water. The contribution of secondary particles to the total dose is less than 4% for electrons and Almost-Equal-To 1% for protons in all the materials of interest. Conclusions: These results demonstrate that the new PRESAGE{sup Registered-Sign} formula may be considered both a tissue- and water-equivalent 3D dosimeter for a 62 MeV proton beam. The results further suggest that tissue-equivalent thickness may provide better dosimetric and geometric accuracy than water-equivalent thickness for 3D dosimetry of this proton beam.« less

  20. Use of standard enteral formula versus enteric formula with prebiotic content in nutrition therapy: A randomized controlled study among neuro-critical care patients.

    PubMed

    Tuncay, Piril; Arpaci, Fatma; Doganay, Mutlu; Erdem, Deniz; Sahna, Arzu; Ergun, Hulya; Atabey, Dilek

    2018-06-01

    To compare use of standard enteral formula versus enteric formula with prebiotic content in terms of nutrition therapy related outcomes among neurocritical care patients. A total of 46 adult neurocritical care patients who received nutrition therapy with standard enteral formula (SEF group; n = 23) or enteral formula with prebiotic content (EFPC group; n = 23) during their hospitalization in intensive care unit (ICU) were included in this prospective randomized controlled study. Data on patient demographics (age, gender), diagnosis, co-morbid diseases, anthropometrics, length of stay (LOS) in hospital and ICU, Nutritional Risk Screening (NRS-2002) score, and Acute Physiology and Chronic Health (APACHE-II) score were recorded at enrollment. Data on daily nutritional intake [total energy (kcal/day), carbohydrate (g/day), protein (g/day), lipid (g/day), FOS (g/day), enteral volume (ml/day), fluid in enteral product (ml/day) and fluid intake (ml/day)], achievement of target dose [total fluid intake in enteral product (ml)/20 h], laboratory findings (blood biochemistry and complete blood count), complications and drug treatments were recorded on Day 1, Day 4, Day 7, Day 14 and Day 21 of nutrition therapy in SEF and EFPC groups. Use of EFPC compared to SEF was associated with significantly higher total energy, carbohydrate, protein, lipid, enteral volume and fluid intake (p values ranged from <0.05 to <0.001) on each day of nutrition therapy. Target dose was achieved by majority of patients (86.9%) and at day 4 of nutrition therapy in most of patients (71.7%) in the overall study population. Patients in the EFPC group had a non-significant tendency for higher rate (95.7% vs. 78.3%) and earlier (87.0% vs. 56.5% on day 4) achievement of target dose, lower rate (8.7% vs. 56.5%) and faster amelioration (none vs. 52.2% were diarrheic on day 7) of diarrhea and lesser need for insulin (56.5% vs. 13.0%, p = 0.002). Nutrition therapy was associated with significant decrease in prealbumin (Day 14 vs. Day 1, p < 0.05 for both), albumin (Day 14 vs. day 1, p < 0.01 for SEF, p < 0.05 for PEF), hemoglobin (Day 14 and Day 21 vs. Day 1and Day 14 vs. Day 4, p < 0.001 for each for SEF, Day 7, Day 14 and Day 21 vs. Day 1, p < 0.01 for each for PEF) and hematocrit (Day 14 and Day 21 vs. Day 1, p < 0.001 for each for both) levels in both SEF and EFPC groups. In conclusion, our findings revealed achievement of target nutritional intake in majority of neurocritical care patients via nutrition therapy, whereas EFPC was associated with a non-significant tendency for more frequent and earlier achievement of target dose along with significantly lower rate and faster amelioration of diarrhea as compared with SEF group. Prealbumin and albumin levels remained below the normal range, whereas C reactive protein (CRP) and white blood cell (WBC) were over the normal range throughout the nutrition period in both groups, while creatinine and urea levels were higher in EFPC than in SEF group. Hence, our findings seem to emphasize the importance of avoiding protein debt in provision of nutrition therapy and the likelihood of deterioration of nutritional status in elderly neurocritical care patients despite provision of early enteral nutrition support due to complex and deleterious inflammatory and metabolic changes during critical illness. Copyright © 2018 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.

  1. Retrospective Comparison of Fludarabine in Combination With Intermediate-Dose Cytarabine Versus High-Dose Cytarabine As Consolidation Therapies for Acute Myeloid Leukemia

    PubMed Central

    Zhang, Wenjun; Ding, Yi; Wu, Hao; Chen, Yuhua; Lu, Huina; Chen, Chunying; Fu, Jianfei; Wang, Weiguang; Liang, Aibin; Zou, Shanhua

    2014-01-01

    Abstract This retrospective study compared efficacy and safety of fludarabine combined with intermediate-dose cytarabine (FA regimen) versus high-dose cytarabine (HiDAC regimen) as consolidation therapy in acute myeloid leukemia (AML) patients who achieved complete remission. Disease-free survival (DFS) and overall survival (OS) based on age (≥60, <60 years) and cytogenetics were evaluated from data between January 2005 and March 2013. Total 82 patients (FA, n = 45; HiDAC, n = 37; 14–65 years) were evaluated. Five-year DFS was 32.0% and 36.2% for FA and HiDAC groups, respectively (P = 0.729), and 5-year OS was 39.5% and 47.8% (P = 0.568), respectively. Among older patients (≥60 years), 3-year DFS was 26.0% for FA group and 12.5% for HiDAC group (P = 0.032), and 3-year OS was 34.6% and 12.5%, respectively (P = 0.026). In FA group, hematological toxicities were significantly lower. FA regimen was as effective as HiDAC regimen in patients with good/intermediate cytogenetics and significantly improved DFS and OS in older patients. PMID:25501050

  2. [Effective combination therapy using radiation and a daily low dose of cis-platinum for advanced oropharyngeal carcinoma in an elderly patient--report of a case].

    PubMed

    Tamura, M; Miyashita, T; Ogiso, A; Kotani, A; Oguchi, M; Izuno, I

    1994-01-01

    An 83-year-old male with advanced oropharyngeal carcinoma was treated with combined radiotherapy and a daily low dose of cis-platinum with excellent results. In the early part of the treatment, radiotherapy was delivered in fractions of 1.8 Gy/day (5 days/week) to a cumulative dose of 20 Gy, concomitantly with UFT (400 mg/day po), but the response was not adequate. Then, instead of UFT, a single intravenous injection of cis-platinum (5 mg) was administered within 30 min after each radiation session without intravenous hydration. The total dose of cis-platinum was 140 mg and that of radiation was 70 Gy. Moderate leukocytopenia and moderate mucositis/dermatitis were observed as side effects, but despite the lack of intravenous hydration no signs of renal toxicity were observed. Partial remission was attained by the end of the therapy, remnant lesions progressively diminished in size, and 4 months later all of them had completely disappeared on the computed tomogram. The prognosis is favorable, and neither recurrence nor metastasis has been found in the 14-month follow-up period since the lesions disappeared.

  3. INFLUENCE OF X-IRRADIATION UPON ACTIVITY OF CHOLINESTERASE IN LIVER AND SERUM. PARTS I-III

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ioroi, M.

    1960-01-01

    The activity of cholinesterase in the liver, studied in rabbits and rats, was more inhibited when the liver was irradiated by a single x-ray dose than by fractionated doses. With l00, 300, and 600 r of whole-body irradiation, the activity of cholinesterase in the liver was stimulated; meanwhile in serum it was inhibited. With l000 and 2000 r, the activities in both serum and liver were severely inhibited. WWhen the diencephalon and spinal cord were irradiated with fractionated doses (l50 r twice a week), the activity of cholinesterase in both liver and serum showed no appreciable change. When whole-body irradiationmore » (l00 r per day) was given, the activity of cholinesterase in both liver and serum was somewhat stimulated. After liver irradiation (200 r per day; total dose 4000 r) the activity of cholinesterase in both liver and serum was inhibited. In patients who showed high activity of cholinesterase in serum before x-ray therapy, the activity was slightly inhibited after x-ray treatment, and patients who showed low activity before therapy were slightly stimulated after x irradiation. (Abstr. Japan Med., l: No. 13, l96l)« less

  4. Xerostomia in patients treated for oropharyngeal carcinoma: comparing linear accelerator-based intensity-modulated radiation therapy with helical tomotherapy.

    PubMed

    Fortin, Israël; Fortin, Bernard; Lambert, Louise; Clavel, Sébastien; Alizadeh, Moein; Filion, Edith J; Soulières, Denis; Bélair, Manon; Guertin, Louis; Nguyen-Tan, Phuc Felix

    2014-09-01

    In comparison to sliding-window intensity-modulated radiation therapy (sw-IMRT), we hypothesized that helical tomotherapy (HT) would achieve similar locoregional control and, at the same time, decrease the parotid gland dose, thus leading to a xerostomia reduction. The association between radiation techniques, mean parotid dose, and xerostomia incidence, was reviewed in 119 patients with advanced oropharyngeal carcinoma treated with concurrent chemoradiation using sw-IMRT (n = 59) or HT (n = 60). Ipsilateral and contralateral parotid mean doses were significantly lower for patients treated with HT versus sw-IMRT: 24 Gy versus 32 Gy ipsilaterally and 20 Gy versus 25 Gy contralaterally. The incidence of grade ≥2 xerostomia was significantly lower in the HT group than in the sw-IMRT group: 12% versus 78% at 6 months, 3% versus 51% at 12 months, and 0% versus 25% at 24 months. Total parotid mean dose <25 Gy was strongly associated to a lower incidence of grade ≥2 xerostomia at 6, 12, and 24 months. This retrospective series suggests that using HT can better spare the parotid glands while respecting quantitative analysis of normal tissue effects in the clinic (QUANTEC)'s criteria. Copyright © 2013 Wiley Periodicals, Inc.

  5. Stereotactic Body Radiation Therapy for Locally Advanced Pancreatic Cancer: A Systematic Review and Pooled Analysis of 19 Trials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petrelli, Fausto, E-mail: faupe@libero.it; Comito, Tiziana; Ghidini, Antonio

    Purpose: Although surgery is the standard of care for resectable pancreatic cancer (PC), standard-dose chemoradiation therapy and chemotherapy alone are suitable for patients with unresectable disease. Stereotactic body radiation therapy (SBRT) is an alternative, focused local therapy that delivers high radiation doses within a few fractions to the cancer, sparing the surrounding critical tissue. We performed a systematic review and pooled analysis of published trials to evaluate the efficacy and safety of this emerging treatment modality. Methods and Materials: We searched the Cochrane Central Register of Controlled Trials, PubMed, EMBASE, SCOPUS, the Web of Science, and CINAHL for publications regardingmore » SBRT for locally advanced PC. The 1-year overall survival (OS) rate was the primary endpoint, and the median OS, 2-year OS rate, 1-year locoregional control (LRC) rate, and grade 3 to 4 toxicities were the secondary endpoints. A multivariate random-effects meta-analysis was performed to calculate the aggregated OS rates at 1 and 2 years and the 1-year LRC rate. Results: A total of 19 studies, encompassing 1009 patients, were included in the present analysis. The pooled 1-year OS was 51.6% in 13 trials with data available. The median OS ranged from 5.7 to 47 months (median 17). The LRC rate at 1 year was 72.3%. Overall, the occurrence of severe adverse events did not exceed 10%. LRC appeared to correlate with the total SBRT dose and the number of fractions. Conclusions: The advantages of SBRT in terms of treatment time, satisfactory OS, and LRC indicate that it is an effective option for inoperable PC. However, a definitive validation of this treatment modality in large randomized studies is required, owing to the nonrandomized nature of the included studies and the limitations of small single-center series that include mixed populations.« less

  6. [Efficacy of granisetron for preventing chemotherapy-induced nausea and vomiting in patients with acute myelogenous leukemia treated with a combination of anthracycline and cytarabine].

    PubMed

    Goto, Takashi; Tanimoto, Kazuki; Ishibashi, Makoto; Okamura, Seiichi

    2012-08-01

    In Japan, the combination of anthracycline and cytarabine(Ara-C)is a standard therapy for acute myelogenous leukemia(AML). Chemotherapy-induced nausea and vomiting(CINV)are frequently reported as side effects related to the administration of these regimens. In our hospital, patients received prophylactic granisetron at a dose of 3 mg daily during chemotherapy. However, granisetron is known to induce constipation as a side effect. The present study evaluated the efficacy of a single dose of granisetron administered throughout the entire period of chemotherapy in AML patients receiving anthracycline and Ara-C combination therapy, and also examined the incidence of constipation during chemotherapy. From July 2008 to December 2010, all patients with AML treated using anthracycline and Ara-C combination therapy were registered in the study. This retrospective study investigated the patients' background and the incidence of CINV and constipation from the patients' records. The efficacy of granisetron was measured on each day using the complete regression(no vomiting and no rescue medication; CR)rate. A total of 45 patients were included in the study(27 male; 18 female), and received a total 68 courses(56 of induction therapy; 12 of consolidation therapy)of the regimens. The CR rate and the incidence of constipation on the final day of chemotherapy were 61. 8% and 63. 2%, respectively. As the duration of chemotherapy increased, the CR rate tended to decrease, whereas the incidence of constipation tended to increase. The CR rate in this study was 61. 8%, thus indicating that there is still room for improvement. The combination of dexamethasone and a neurokinin-1 receptor antagonist, or the changeover from granisetron to palonosetron could therefore increase the CR rate.

  7. The dosimetric effects of photon energy on the quality of prostate volumetric modulated arc therapy.

    PubMed

    Mattes, Malcolm D; Tai, Cyril; Lee, Alvin; Ashamalla, Hani; Ikoro, N C

    2014-01-01

    Studies comparing the dosimetric effects of high- and low-energy photons to treat prostate cancer using 3-dimensional conformal and intensity modulated radiation therapy have yielded mixed results. With the advent of newer radiation delivery systems like volumetric modulated arc therapy (VMAT), the impact of changing photon energy is readdressed. Sixty-five patients treated for prostate cancer at our institution from 2011 to 2012 underwent CT simulation. A target volume encompassing the prostate and entire seminal vesicles was treated to 50.4 Gy, followed by a boost to the prostate and proximal seminal vesicles to a total dose of 81 Gy. The VMAT plans were generated for 6-MV and 10-MV photons under identical optimization conditions using the Eclipse system version 8.6 (Varian Medical Systems, Palo Alto, CA). The analytical anisotropic algorithm was used for all dose calculations. Plans were normalized such that 98% of the planning target volume (PTV) received 100% of the prescribed dose. Dose-volumetric data from the treatment planning system was recorded for both 6-MV and 10-MV plans, which were compared for both the entire cohort and subsets of patients stratified according to the anterior-posterior separation. Plans using 10-MV photons had statistically significantly lower relative integral dose (4.1%), gradient measure (4.1%), skin Dmax (16.9%), monitor units (13.0%), and bladder V(30) (3.1%) than plans using 6-MV photons (P < .05). There was no difference in rectal dose, high-dose-region bladder dose, PTV coverage, or conformity index. The benefit of 10-MV photons was more pronounced for thicker patients (anterior-posterior separation >21 cm) for most parameters, with statistically significant differences in bladder V(30), bladder V(65), integral dose, conformity index, and monitor units. The main dosimetric benefits of 10-MV as compared with 6-MV photons are seen in thicker patients, though for the entire cohort 10-MV plans resulted in a lower integral dose, gradient measure, skin Dmax, monitor units, and bladder V(30), possibly at the expense of higher rectum V(81). Copyright © 2014 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  8. Dosimetric verification and clinical evaluation of a new commercially available Monte Carlo-based dose algorithm for application in stereotactic body radiation therapy (SBRT) treatment planning

    NASA Astrophysics Data System (ADS)

    Fragoso, Margarida; Wen, Ning; Kumar, Sanath; Liu, Dezhi; Ryu, Samuel; Movsas, Benjamin; Munther, Ajlouni; Chetty, Indrin J.

    2010-08-01

    Modern cancer treatment techniques, such as intensity-modulated radiation therapy (IMRT) and stereotactic body radiation therapy (SBRT), have greatly increased the demand for more accurate treatment planning (structure definition, dose calculation, etc) and dose delivery. The ability to use fast and accurate Monte Carlo (MC)-based dose calculations within a commercial treatment planning system (TPS) in the clinical setting is now becoming more of a reality. This study describes the dosimetric verification and initial clinical evaluation of a new commercial MC-based photon beam dose calculation algorithm, within the iPlan v.4.1 TPS (BrainLAB AG, Feldkirchen, Germany). Experimental verification of the MC photon beam model was performed with film and ionization chambers in water phantoms and in heterogeneous solid-water slabs containing bone and lung-equivalent materials for a 6 MV photon beam from a Novalis (BrainLAB) linear accelerator (linac) with a micro-multileaf collimator (m3 MLC). The agreement between calculated and measured dose distributions in the water phantom verification tests was, on average, within 2%/1 mm (high dose/high gradient) and was within ±4%/2 mm in the heterogeneous slab geometries. Example treatment plans in the lung show significant differences between the MC and one-dimensional pencil beam (PB) algorithms within iPlan, especially for small lesions in the lung, where electronic disequilibrium effects are emphasized. Other user-specific features in the iPlan system, such as options to select dose to water or dose to medium, and the mean variance level, have been investigated. Timing results for typical lung treatment plans show the total computation time (including that for processing and I/O) to be less than 10 min for 1-2% mean variance (running on a single PC with 8 Intel Xeon X5355 CPUs, 2.66 GHz). Overall, the iPlan MC algorithm is demonstrated to be an accurate and efficient dose algorithm, incorporating robust tools for MC-based SBRT treatment planning in the routine clinical setting.

  9. A Contralateral Esophagus-Sparing Technique to Limit Severe Esophagitis Associated With Concurrent High-Dose Radiation and Chemotherapy in Patients With Thoracic Malignancies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Al-Halabi, Hani; Paetzold, Peter; Sharp, Gregory C.

    2015-07-15

    Purpose: Severe (Radiation Therapy Oncology Group [RTOG] grade 3 or greater) esophagitis generally occurs in 15% to 25% of non–small cell lung cancer (NSCLC) patients undergoing concurrent chemotherapy and radiation therapy (CCRT), which may result in treatment breaks that compromise local tumor control and pose a barrier to dose escalation. Here, we report a novel contralateral esophagus-sparing technique (CEST) that uses intensity modulated radiation therapy (IMRT) to reduce the incidence of severe esophagitis. Methods and Materials: We reviewed consecutive patients with thoracic malignancies undergoing curative CCRT in whom CEST was used. The esophageal wall contralateral (CE) to the tumor wasmore » contoured as an avoidance structure, and IMRT was used to guide a rapid dose falloff gradient beyond the target volume in close proximity to the esophagus. Esophagitis was recorded based on the RTOG acute toxicity grading system. Results: We identified 20 consecutive patients treated with CCRT of at least 63 Gy in whom there was gross tumor within 1 cm of the esophagus. The median radiation dose was 70.2 Gy (range, 63-72.15 Gy). In all patients, ≥99% of the planning and internal target volumes was covered by ≥90% and 100% of prescription dose, respectively. Strikingly, no patient experienced grade ≥3 esophagitis (95% confidence limits, 0%-16%) despite the high total doses delivered. The median maximum dose, V45, and V55 of the CE were 60.7 Gy, 2.1 cc, and 0.4 cc, respectively, indicating effective esophagus cross-section sparing by CEST. Conclusion: We report a simple yet effective method to avoid exposing the entire esophagus cross-section to high doses. By using proposed CE dose constraints of V45 <2.5 cc and V55 <0.5 cc, CEST may improve the esophagus toxicity profile in thoracic cancer patients receiving CCRT even at doses above the standard 60- to 63-Gy levels. Prospective testing of CEST is warranted.« less

  10. Preliminary Results of a Phase 1 Dose-Escalation Trial for Early-Stage Breast Cancer Using 5-Fraction Stereotactic Body Radiation Therapy for Partial-Breast Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rahimi, Asal, E-mail: asal.rahimi@utsouthwestern.edu; Thomas, Kimberly; Spangler, Ann

    Purpose: To evaluate the tolerability of a dose-escalated 5-fraction stereotactic body radiation therapy for partial-breast irradiation (S-PBI) in treating early-stage breast cancer after partial mastectomy; the primary objective was to escalate dose utilizing a robotic stereotactic radiation system treating the lumpectomy cavity without exceeding the maximum tolerated dose. Methods and Materials: Eligible patients included those with ductal carcinoma in situ or invasive nonlobular epithelial histologies and stage 0, I, or II, with tumor size <3 cm. Patients and physicians completed baseline and subsequent cosmesis outcome questionnaires. Starting dose was 30 Gy in 5 fractions and was escalated by 2.5 Gy total for each cohortmore » to 40 Gy. Results: In all, 75 patients were enrolled, with a median age of 62 years. Median follow-up for 5 cohorts was 49.9, 42.5, 25.7, 20.3, and 13.5 months, respectively. Only 3 grade 3 toxicities were experienced. There was 1 dose-limiting toxicity in the overall cohort. Ten patients experienced palpable fat necrosis (4 of which were symptomatic). Physicians scored cosmesis as excellent or good in 95.9%, 100%, 96.7%, and 100% at baseline and 6, 12, and 24 months after S-PBI, whereas patients scored the same periods as 86.5%, 97.1%, 95.1%, and 95.3%, respectively. The disagreement rates between MDs and patients during those periods were 9.4%, 2.9%, 1.6%, and 4.7%, respectively. There have been no recurrences or distant metastases. Conclusion: Dose was escalated to the target dose of 40 Gy in 5 fractions, with the occurrence of only 1 dose-limiting toxicity. Patients felt cosmetic results improved within the first year after surgery and stereotactic body radiation therapy. Our results show minimal toxicity with excellent cosmesis; however, further follow-up is warranted in future studies. This study is the first to show the safety, tolerability, feasibility, and cosmesis results of a 5-fraction dose-escalated S-PBI treatment for early-stage breast cancer in the adjuvant setting.« less

  11. Micafungin Plasma Levels Are Not Affected by Continuous Renal Replacement Therapy: Experience in Critically Ill Patients.

    PubMed

    Vossen, M G; Knafl, D; Haidinger, M; Lemmerer, R; Unger, M; Pferschy, S; Lamm, W; Maier-Salamon, A; Jäger, W; Thalhammer, F

    2017-08-01

    Critically ill patients often experience acute kidney injury and the need for renal replacement therapy in the course of their treatment in an intensive care unit (ICU). These patients are at an increased risk for candidiasis. Although there have been several reports of micafungin disposition during renal replacement therapy, to this date there are no data describing the elimination of micafungin during high-dose continuous venovenous hemodiafiltration with modified AN69 membranes. The aim of this prospective open-label pharmacokinetic study was to assess whether micafungin plasma levels are affected by continuous hemodiafiltration in critical ill patients using the commonly employed AN69 membrane. A total of 10 critically ill patients with micafungin treatment due to suspected or proven candidemia were included in this trial. Prefilter/postfilter micafungin clearance was measured to be 46.0 ml/min (±21.7 ml/min; n = 75 individual time points), while hemofilter clearance calculated by the sieving coefficient was 0.0038 ml/min (±0.002 ml/min; n = 75 individual time points). Total body clearance was measured to be 14.0 ml/min (±7.0 ml/min; n = 12). The population area under the curve from 0 to 24 h (AUC 0-24 ) was calculated as 158.5 mg · h/liter (±79.5 mg · h/liter; n = 13). In spite of high protein binding, no dose modification is necessary in patients receiving continuous venovenous hemodiafiltration with AN69 membranes. A dose elevation may, however, be justified in certain cases. (This study has been registered at ClinicalTrials.gov under identifier NCT02651038.). Copyright © 2017 American Society for Microbiology.

  12. Single institution experience treating 104 vestibular schwannomas with fractionated stereotactic radiation therapy or stereotactic radiosurgery.

    PubMed

    Anderson, Bethany M; Khuntia, Deepak; Bentzen, Søren M; Geye, Heather M; Hayes, Lori L; Kuo, John S; Baskaya, Mustafa K; Badie, Behnam; Basavatia, Amar; Pyle, G Mark; Tomé, Wolfgang A; Mehta, Minesh P

    2014-01-01

    The pupose of this study is to assess the long-term outcome and toxicity of fractionated stereotactic radiation therapy (FSRT) and stereotactic radiosurgery (SRS) for 100 vestibular schwannomas treated at a single institution. From 1993 to 2007, 104 patients underwent were treated with radiation therapy for vestibular schwannoma. Forty-eight patients received SRS, with a median prescription dose of 12.5 Gy for SRS (range 9.7-16 Gy). For FSRT, two different fraction schedules were employed: a conventional schedule (ConFSRT) of 1.8 Gy per fraction (Gy/F) for 25 or 28 fractions to a total dose of 45 or 50.4 Gy (n = 19); and a once weekly hypofractionated course (HypoFSRT) consisting of 4 Gy/F for 5 fractions to a total dose of 20 Gy (n = 37). Patients treated with FSRT had better baseline hearing, facial, and trigeminal nerve function, and were more likely to have a diagnosis of NF2. The 5-year progression free rate (PFR) was 97.0 after SRS, 90.5% after HypoFSRT, and 100.0% after ConFSRT (p = NS). Univariate analysis demonstrated that NF2 and larger tumor size (greater than the median) correlated with poorer local control, but prior surgical resection did not. Serviceable hearing was preserved in 60.0% of SRS patients, 63.2% of HypoFSRT patients, and 44.4% of ConFSRT patients (p = 0.6). Similarly, there were no significant differences in 5-year rates of trigeminal toxicity facial nerve toxicity, vestibular dysfunction, or tinnitus. Equivalent 5-year PFR and toxicity rates are shown for patients with vestibular schwanoma selected for SRS, HypoFSRT, and ConFSRT after multidisciplinary evaluation. Factors correlating with tumor progression included NF2 and larger tumor size.

  13. Experimental photodynamic laser therapy for rheumatoid arthritis with a second generation photosensitizer.

    PubMed

    Hendrich, C; Hüttmann, G; Vispo-Seara, J L; Houserek, S; Siebert, W E

    2000-01-01

    Photodynamic laser therapy has been shown to be a new method for the treatment of synovitis in various animal models. Its principle is the accumulation of a photosensitizing drug in the inflamed synovium which is destroyed by photoactivation of the drug. In the present animal study we demonstrate the effect of a second-generation photosensitizer and suggest a concept for light dosimetry within the joint. We used 38 inbred rabbits for the IgG-induced arthritis model; 2 mg/kg of the benzoporphyrin derivative monoacid ring-A (BPD-MA) Verteporfin were administered 3 h before irradiation, which was performed using a 690-nm diode laser coupled to quartz glass fiber with a cylinder diffusor tip at a total light energy of either 180 or 470 J. During irradiation specific fluorescence of BPD-MA was monitored using a spectroscopy unit. The effect of the photodynamic laser therapy was documented grossly and histologically after 1 week. Within the 470 J-group a complete necrosis of the inflamed synovium was observed. The bradytrophic structures of the joint, however, remained unchanged. Throughout the 180 J-group the extent of necrosis was minor. During irradiation the tissue fluorescence of BPD-MA showed a dose-dependent decrease. Using BPD-MA as a photosensitizer a highly selective and minimal invasive synoviorthesis can be performed. At a dose of 2 mg/kg the histological effect depends on the light dose. For optimum efficacy a total energy of 470 J seems favorable. Online fluorescence detection can be used to monitor the effect of light administration. For dosimetry therefore an online tissue fluorescence detection may represent a technical solution.

  14. Accelerated hypofractionated three-dimensional conformal radiation therapy (3 Gy/fraction) combined with concurrent chemotherapy for patients with unresectable stage III non-small cell lung cancer: preliminary results of an early terminated phase II trial.

    PubMed

    Ren, Xiao-Cang; Wang, Quan-Yu; Zhang, Rui; Chen, Xue-Ji; Wang, Na; Liu, Yue-E; Zong, Jie; Guo, Zhi-Jun; Wang, Dong-Ying; Lin, Qiang

    2016-04-23

    Increasing the biological effective dose (BED) of radiotherapy for non-small cell lung cancer (NSCLC) can increase local control rates and improve overall survival. Compared with conventional fractionated radiotherapy, accelerated hypofractionated radiotherapy can yield higher BED, shorten the total treatment time, and theoretically obtain better efficacy. However, currently, there is no optimal hypofractionated radiotherapy regimen. Based on phase I trial results, we performed this phase II trial to further evaluate the safety and preliminary efficacy of accelerated hypofractionated three-dimensional conformal radiation therapy(3-DCRT) combined with concurrent chemotherapy for patients with unresectable stage III NSCLC. Patients with previously untreated unresectable stage III NSCLC received 3-DCRT with a total dose of 69 Gy, delivered at 3 Gy per fraction, once daily, five fractions per week, completed within 4.6 weeks. At the same time, platinum doublet chemotherapy was applied. After 12 patients were enrolled in the group, the trial was terminated early. There were five cases of grade III radiation esophagitis, of which four cases completed the radiation doses of 51 Gy, 51 Gy, 54 Gy, and 66 Gy, and one case had 16 days of radiation interruption. The incidence of grade III acute esophagitis in patients receiving an irradiation dose per fraction ≥2.7 Gy on the esophagus was 83.3% (5/6). The incidence of symptomatic grade III radiation pneumonitis among the seven patients who completed 69 Gy according to the plan was 28.6% (2/7). The median local control (LC) and overall survival (OS) were not achieved; the 1-year LC rate was 59.3%, and the 1-year OS rate was 78.6%. For unresectable stage III NSCLC, the accelerated hypofractionated radiotherapy with a total dose of 69 Gy (3 Gy/f) combined with concurrent chemotherapy might result in severe radiation esophagitis and pneumonitis to severely affect the completion of the radiotherapy. Therefore, we considered that this regimen was infeasible. During the hypofractionated radiotherapy with concurrent chemotherapy, the irradiation dose per fraction to esophagus should be lower than 2.7 Gy. Further studies should be performed using esophageal tolerance as a metric in dose escalation protocols. NCT02720614, the date of registration: March 23, 2016.

  15. Comparison of the Light Charged Particles on Scatter Radiation Dose in Thyroid Hadron Therapy

    PubMed Central

    Azizi, M; Mowlavi, AA

    2014-01-01

    Background: Hadron therapy is a novel technique of cancer radiation therapy which employs charged particles beams, 1H and light ions in particular. Due to their physical and radiobiological properties, they allow one to obtain a more conformal treatment, sparing better the healthy tissues located in proximity of the tumor and allowing a higher control of the disease. Objective: As it is well known, these light particles can interact with nuclei in the tissue, and produce the different secondary particles such as neutron and photon. These particles can damage specially the critical organs behind of thyroid gland. Methods: In this research, we simulated neck geometry by MCNPX code and calculated the light particles dose at distance of 2.14 cm in thyroid gland, for different particles beam: 1H, 2H, 3He, and 4He. Thyroid treatment is important because the spine and vertebrae is situated right behind to the thyroid gland on the posterior side. Results: The results show that 2H has the most total flux for photon and neutron, 1.944E-3 and 1.7666E-2, respectively. Whereas 1H and 3He have best conditions, 8.88609E-4 and 1.35431E-3 for photon, 4.90506E-4 and 4.34057E-3 for neutron, respectively. The same calculation has obtained for energy depositions for these particles. Conclusion: In this research, we investigated that which of these light particles can deliver the maximum dose to the normal tissues and the minimum dose to the tumor. By comparing these results for the mentioned light particles, we find out 1H and 3He is the best therapy choices for thyroid glands whereas 2H is the worst. PMID:25505774

  16. Phase I Design for Completely or Partially Ordered Treatment Schedules

    PubMed Central

    Wages, Nolan A.; O’Quigley, John; Conaway, Mark R.

    2013-01-01

    The majority of methods for the design of Phase I trials in oncology are based upon a single course of therapy, yet in actual practice it may be the case that there is more than one treatment schedule for any given dose. Therefore, the probability of observing a dose-limiting toxicity (DLT) may depend upon both the total amount of the dose given, as well as the frequency with which it is administered. The objective of the study then becomes to find an acceptable combination of both dose and schedule. Past literature on designing these trials has entailed the assumption that toxicity increases monotonically with both dose and schedule. In this article, we relax this assumption for schedules and present a dose-schedule finding design that can be generalized to situations in which we know the ordering between all schedules and those in which we do not. We present simulation results that compare our method to other suggested dose-schedule finding methodology. PMID:24114957

  17. Flutamide-metformin plus an oral contraceptive (OC) for young women with polycystic ovary syndrome: switch from third- to fourth-generation OC reduces body adiposity.

    PubMed

    Ibáñez, Lourdes; De Zegher, Francis

    2004-08-01

    Low-dose flutamide-metformin has been developed as a background therapy for non-obese adolescents and young women with hyperinsulinaemic hyperandrogenism, a variant of polycystic ovary syndrome (PCOS). We verified whether the lipolytic efficacy of flutamide-metformin in women with PCOS is enhanced by giving an oral contraceptive (OC) co-therapy that contains drospirenone, instead of gestodene, as progestin. An open-labelled study was carried out in which non-obese women with PCOS (n = 29; age approximately 20 years), who had been on a combination of flutamide (62.5 mg/day), metformin (850 mg/day) and ethinylestradiol-gestodene for 8-15 months, were randomized for replacement of the gestodene OC by a drospirenone OC. Assessments of endocrine-metabolic state and body composition (by dual-energy X-ray absorptiometry) were performed at randomization and after 6 months. The switch to drospirenone OC was accompanied by a reduction of total and abdominal fat (mean -0.8 and -0.5 kg) and by an increment of lean body mass (+0.6 kg; all P < 0.01), so that body adiposity was strikingly reduced without changing body weight. In non-obese women with PCOS, low-dose flutamide-metformin reduces total and abdominal fat excess more effectively if contraceptive co-therapy contains drospirenone, instead of gestodene, as progestin. Copyright 2004 European Society of Human Reproduction and Embryology

  18. SU-F-T-197: Investigating Optimal Oblique-Beam Arrangement for Bilateral Metallic Prosthesis Prostate Cancer in Pencil Beam Scanning Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rana, S; Tesfamicael, B; Park, S

    Purpose: The main purpose of this study is to investigate the optimum oblique-beam arrangement for bilateral metallic prosthesis prostate cancer treatment in pencil beam scanning (PBS) proton therapy. Methods: A computed tomography dataset of bilateral metallic prosthesis prostate cancer case was selected for this retrospective study. A total of four beams (rightanterior- oblique [RAO], left-anterior-oblique [LAO], left-posterior-oblique [LPO], and right-posterior-oblique [RPO]) were selected for treatment planning. PBS plans were generated using multi-field-optimization technique for a total dose of 79.2 Gy[RBE] to be delivered in 44 fractions. Specifically, five different PBS plans were generated based on 2.5% ± 2 mm rangemore » uncertainty using five different beam arrangements (i)LAO+RAO+LPO+RPO, (ii)LAO+RAO, (iii)LPO+RPO, (iv)RAO+LPO, and (v)LAO+RPO. Each PBS plan was optimized by applying identical dose-volume constraints to the PTV, rectum, and bladder. Treatment plans were then compared based on the dose-volume histograms results. Results: The PTV coverage was found to be greater than 99% in all five plans. The homogeneity index (HI) was found to be almost identical (range, 0.03–0.04). The PTV mean dose was found to be comparable (range, 81.0–81.1 Gy[RBE]). For the rectum, the lowest mean dose (8.0 Gy[RBE]) and highest mean dose (31.1 Gy[RBE]) were found in RAO+LAO plan and LPO+RPO plan, respectively. LAO+RAO plan produced the most favorable dosimetric results of the rectum in the medium-dose region (V50) and high-dose region (V70). For the bladder, the lowest (5.0 Gy[RBE]) and highest mean dose (10.3 Gy[RBE]) were found in LPO+RPO plan and RAO+LAO plan, respectively. Other dosimetric results (V50 and V70) of the bladder were slightly better in LPO+RPO plan than in other plans. Conclusion: Dosimetric findings from this study suggest that two anterior-oblique proton beams arrangement (LAO+RAO) is a more favorable option with the possibility of reducing rectal dose significantly while maintaining comparable target coverage and acceptable bladder dose.« less

  19. Study design and early result of a phase I study of SABR for early-stage glottic cancer.

    PubMed

    Yu, Tosol; Wee, Chan Woo; Choi, Noorie; Wu, Hong-Gyun; Kang, Hyun-Cheol; Park, Jong Min; Kim, Jung-In; Kim, Jin Ho; Kwon, Tack-Kyun; Chung, Eun-Jae

    2018-05-14

    Avoidance of organs at risk has become possible with advances in image-guided volumetric-modulated arc therapy (VMAT) techniques. This study was designed to evaluate the safety and feasibility of stereotactic ablative radiotherapy (SABR) for early stage glottic cancer. This report presents the preliminary result of the first and second dose level. Fraction size was increased from 3.5 gray (Gy) (total dose 59.5 Gy) to 9 Gy (total dose 45 Gy). Dose-limiting toxicities were defined as grade 3 or higher treatment-related toxicities. Voice outcome was assessed with electroglottography, and quality of life (QoL) was measured with the Head and Neck Cancer Inventory (HNCI). Seven patients received 59.5 Gy at 3.5 Gy per fraction as the first dose level, and five patients received 55 Gy at 5 Gy per fraction as the second dose level. None of the patients developed grade 3+ toxicity throughout a median follow-up of 17.5 months (range, 1.7-30.6 months). One patient in the second dose level recurred in the primary site at 4 months after radiotherapy (RT) and received total laryngectomy. The rest of participants were disease-free at locoregional and distant sites. Jitter, shimmer, mean phonation time, and noise-to-harmony ratio did not change significantly at 6 months after RT. HNCI scores between pretreatment and posttreatment were not significantly different (P = 0.221). This study revealed acceptable toxicity, voice outcome, and QoL in patients treated with hypofractionated VMAT of 3.5 Gy and 5 Gy per fraction. This phase I study is currently ongoing with a dose of 55 Gy in 11 fractions and 45 Gy in five fractions. 2b. Laryngoscope, 2018. © 2018 The American Laryngological, Rhinological and Otological Society, Inc.

  20. Low dose Naltrexone for induction of remission in inflammatory bowel disease patients.

    PubMed

    Lie, Mitchell R K L; van der Giessen, Janine; Fuhler, Gwenny M; de Lima, Alison; Peppelenbosch, Maikel P; van der Ent, Cokkie; van der Woude, C Janneke

    2018-03-09

    Around 30% of patients with inflammatory bowel disease (IBD) are refractory to current IBD drugs or relapse over time. Novel treatments are called for, and low dose Naltrexone (LDN) may provide a safe, easily accessible alternative treatment option for these patients. We investigated the potential of LDN to induce clinical response in therapy refractory IBD patients, and investigated its direct effects on epithelial barrier function. Patients not in remission and not responding to conventional therapy were offered to initiate LDN as a concomitant treatment. In total 47 IBD patients prescribed LDN were followed prospectively for 12 weeks. Where available, endoscopic remission data, serum and biopsies were collected. Further the effect of Naltrexone on wound healing (scratch assay), cytokine production and endoplasmic reticulum (ER) stress (GRP78 and CHOP western blot analysis, immunohistochemistry) were investigated in HCT116 and CACO2 intestinal epithelial cells, human IBD intestinal organoids and patient samples. Low dose Naltrexone induced clinical improvement in 74.5%, and remission in 25.5% of patients. Naltrexone improved wound healing and reduced ER stress induced by Tunicamycin, lipopolysaccharide or bacteria in epithelial barriers. Inflamed mucosa from IBD patients showed high ER stress levels, which was reduced in patients treated with LDN. Cytokine levels in neither epithelial cells nor serum from IBD patients were affected. Naltrexone directly improves epithelial barrier function by improving wound healing and reducing mucosal ER stress levels. Low dose Naltrexone treatment is effective and safe, and could be considered for the treatment of therapy refractory IBD patients.

  1. Comparison of twice-daily vs once-daily deferasirox dosing in a gerbil model of iron cardiomyopathy

    PubMed Central

    Otto-Duessel, Maya; Aguilar, Michelle; Nick, Hanspeter; Moats, Rex; Wood, John C.

    2010-01-01

    Objective Despite the availability of deferoxamine chelation therapy for more than 20 years, iron cardiomyopathy remains the leading cause of death in thalassemia major patients. Effective chelation of cardiac iron is difficult; cardiac iron stores respond more slowly to chelation therapy and require a constant gradient of labile iron species between serum and myocytes. We have previously demonstrated the efficacy of once-daily deferasirox in removing previously stored cardiac iron in the gerbil, but changes in cardiac iron were relatively modest compared with hepatic iron. We postulated that daily divided dosing, by sustaining a longer labile iron gradient from myocytes to serum, would produce better cardiac iron chelation than a comparable daily dose. Methods Twenty-four 8- to 10-week-old female gerbils underwent iron dextran—loading for 10 weeks, followed by a 1-week iron equilibration period. Animals were divided into three treatment groups of eight animals each and were treated with deferasirox 100 mg/kg/day as a single dose, deferasirox 100 mg/kg/day daily divided dose, or sham chelation for a total of 12 weeks. Following euthanasia, organs were harvested for quantitative iron and tissue histology. Results Hepatic and cardiac iron contents were not statistically different between the daily single-dose and daily divided-dose groups. However, the ratio of cardiac to hepatic iron content was lower in the divided-dose group (0.78% vs 1.11%, p = 0.0007). Conclusion Daily divided dosing of deferasirox changes the relative cardiac and liver iron chelation profile compared with daily single dosing, trading improvements in cardiac iron elimination for less-effective hepatic chelation. PMID:17588475

  2. Buprenorphine transdermal system utilization.

    PubMed

    Wallace, Laura; Kadakia, Aditi

    2017-01-01

    To evaluate utilization patterns in patients initiating buprenorphine transdermal system (BTDS), CIII, and estimate the proportion decreasing their total opioid dose over time. This retrospective cohort study used data from the Truven Health Analytics MarketScan® Commercial Claims and Encounters Database from 1 January 2011 through 31 December 2015. Eligible individuals were adults aged 18-64 years newly dispensed BTDS (index prescription) who had at least six months of insurance coverage prior to (baseline period) and following (study period) the index prescription. Back and neck pain was the most common pain condition in the study population (n = 31,533) and 88% were dispensed opioids in the baseline period. Nearly half (48%) received BTDS in a strength of 10 mcg/hour as their index prescription. Most (80%) patients prescribed BTDS had concomitant prescriptions for other opioids, chiefly immediate-release (IR) opioids (77%). During the baseline period, median opioid dose among patients prescribed opioids was 50 morphine-equivalent doses (MED), with 33% of patients using nonsteroidal anti-inflammatory drugs and 44% adjuvant analgesics. During the study period, BTDS use lasted a median 30 days and mean 100 days. Median dose of BTDS remained largely constant, and median dose of all opioids during continuous use of BTDS was 65.6 units MED. However, 24% of patients reduced total units MED from the baseline period (median mean dose, 74.5 units MED) until the end of the study period (42.8). Most patients initiating treatment with BTDS had a history of treatment with IR opioids. Though the average change in total opioid daily dose after patients were prescribed BTDS was modest, an important subpopulation of approximately one-quarter of patients were able to markedly reduce their total units MED compared with prior opioid therapy. BTDS should be investigated as an option to help patients step down from higher opioid doses.

  3. Calculation of Absorbed Dose in Target Tissue and Equivalent Dose in Sensitive Tissues of Patients Treated by BNCT Using MCNP4C

    NASA Astrophysics Data System (ADS)

    Zamani, M.; Kasesaz, Y.; Khalafi, H.; Pooya, S. M. Hosseini

    Boron Neutron Capture Therapy (BNCT) is used for treatment of many diseases, including brain tumors, in many medical centers. In this method, a target area (e.g., head of patient) is irradiated by some optimized and suitable neutron fields such as research nuclear reactors. Aiming at protection of healthy tissues which are located in the vicinity of irradiated tissue, and based on the ALARA principle, it is required to prevent unnecessary exposure of these vital organs. In this study, by using numerical simulation method (MCNP4C Code), the absorbed dose in target tissue and the equiavalent dose in different sensitive tissues of a patiant treated by BNCT, are calculated. For this purpose, we have used the parameters of MIRD Standard Phantom. Equiavelent dose in 11 sensitive organs, located in the vicinity of target, and total equivalent dose in whole body, have been calculated. The results show that the absorbed dose in tumor and normal tissue of brain equal to 30.35 Gy and 0.19 Gy, respectively. Also, total equivalent dose in 11 sensitive organs, other than tumor and normal tissue of brain, is equal to 14 mGy. The maximum equivalent doses in organs, other than brain and tumor, appear to the tissues of lungs and thyroid and are equal to 7.35 mSv and 3.00 mSv, respectively.

  4. Successful pregnancy after total body irradiation and bone marrow transplantation for acute leukaemia.

    PubMed

    Giri, N; Vowels, M R; Barr, A L; Mameghan, H

    1992-07-01

    We report successful pregnancies in two young women (aged 24 and 20 years) following allogeneic bone marrow transplantation (BMT) for acute non-lymphoblastic leukaemia. Conditioning therapy consisted of cyclophosphamide (120 mg/kg) and total body irradiation (TBI, 12 Gy) in 2 Gy fractions once daily for 6 days or twice daily for 3 days. Graft-versus-host disease prophylaxis was with methotrexate alone. Both women were amenorrhoeic after BMT and gonadal testing indicated hypergonadotrophic hypogonadism. Both women had normal pregnancies (2 years and 5 years after BMT) resulting in normal healthy infants. Previously successful pregnancy has been reported after TBI in three women in whom the TBI dose was less than 8 Gy. Our cases illustrate that normal outcome of pregnancy is possible at even higher doses of TBI.

  5. A Voxel-Based Approach to Explore Local Dose Differences Associated With Radiation-Induced Lung Damage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palma, Giuseppe; Monti, Serena; D'Avino, Vittoria

    Purpose: To apply a voxel-based (VB) approach aimed at exploring local dose differences associated with late radiation-induced lung damage (RILD). Methods and Materials: An interinstitutional database of 98 patients who were Hodgkin lymphoma (HL) survivors treated with postchemotherapy supradiaphragmatic radiation therapy was analyzed in the study. Eighteen patients experienced late RILD, classified according to the Radiation Therapy Oncology Group scoring system. Each patient's computed tomographic (CT) scan was normalized to a single reference case anatomy (common coordinate system, CCS) through a log-diffeomorphic approach. The obtained deformation fields were used to map the dose of each patient into the CCS. Themore » coregistration robustness and the dose mapping accuracy were evaluated by geometric and dose scores. Two different statistical mapping schemes for nonparametric multiple permutation inference on dose maps were applied, and the corresponding P<.05 significance lung subregions were generated. A receiver operating characteristic (ROC)-based test was performed on the mean dose extracted from each subregion. Results: The coregistration process resulted in a geometrically robust and accurate dose warping. A significantly higher dose was consistently delivered to RILD patients in voxel clusters near the peripheral medial-basal portion of the lungs. The area under the ROC curves (AUC) from the mean dose of the voxel clusters was higher than the corresponding AUC derived from the total lung mean dose. Conclusions: We implemented a framework including a robust registration process and a VB approach accounting for the multiple comparison problem in dose-response modeling, and applied it to a cohort of HL survivors to explore a local dose–RILD relationship in the lungs. Patients with RILD received a significantly greater dose in parenchymal regions where low doses (∼6 Gy) were delivered. Interestingly, the relation between differences in the high-dose range and RILD seems to lack a clear spatial signature.« less

  6. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT)

    PubMed Central

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham

    2013-01-01

    Introduction Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147–53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. Methods A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. Results The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose–volume histogram (DVH) doses were consistently lower. Conclusion The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques. PMID:26229623

  7. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham

    Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147–53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRTmore » plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose–volume histogram (DVH) doses were consistently lower. The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques.« less

  8. Electromagnetic-Guided MLC Tracking Radiation Therapy for Prostate Cancer Patients: Prospective Clinical Trial Results.

    PubMed

    Keall, Paul J; Colvill, Emma; O'Brien, Ricky; Caillet, Vincent; Eade, Thomas; Kneebone, Andrew; Hruby, George; Poulsen, Per R; Zwan, Benjamin; Greer, Peter B; Booth, Jeremy

    2018-06-01

    To report on the primary and secondary outcomes of a prospective clinical trial of electromagnetic-guided multileaf collimator (MLC) tracking radiation therapy for prostate cancer. Twenty-eight men with prostate cancer were treated with electromagnetic-guided MLC tracking with volumetric modulated arc therapy. A total of 858 fractions were delivered, with the dose per fraction ranging from 2 to 13.75 Gy. The primary outcome was feasibility, with success determined if >95% of fractions were successfully delivered. The secondary outcomes were (1) the improvement in beam-target geometric alignment, (2) the improvement in dosimetric coverage of the prostate and avoidance of critical structures, and (3) no acute grade ≥3 genitourinary or gastrointestinal toxicity. All 858 planned fractions were successfully delivered with MLC tracking, demonstrating the primary outcome of feasibility (P < .001). MLC tracking improved the beam-target geometric alignment from 1.4 to 0.90 mm (root-mean-square error). MLC tracking improved the dosimetric coverage of the prostate and reduced the daily variation in dose to critical structures. No acute grade ≥3 genitourinary or gastrointestinal toxicity was observed. Electromagnetic-guided MLC tracking radiation therapy for prostate cancer is feasible. The patients received improved geometric targeting and delivered dose distributions that were closer to those planned than they would have received without electromagnetic-guided MLC tracking. No significant acute toxicity was observed. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Deconvolution analysis of 24-h serum cortisol profiles informs the amount and distribution of hydrocortisone replacement therapy.

    PubMed

    Peters, Catherine J; Hill, Nathan; Dattani, Mehul T; Charmandari, Evangelia; Matthews, David R; Hindmarsh, Peter C

    2013-03-01

    Hydrocortisone therapy is based on a dosing regimen derived from estimates of cortisol secretion, but little is known of how the dose should be distributed throughout the 24 h. We have used deconvolution analysis of 24-h serum cortisol profiles to determine 24-h cortisol secretion and distribution to inform hydrocortisone dosing schedules in young children and older adults. Twenty four hour serum cortisol profiles from 80 adults (41 men, aged 60-74 years) and 29 children (24 boys, aged 5-9 years) were subject to deconvolution analysis using an 80-min half-life to ascertain total cortisol secretion and distribution throughout the 24-h period. Mean daily cortisol secretion was similar between adults (6.3 mg/m(2) body surface area/day, range 5.1-9.3) and children (8.0 mg/m(2) body surface area/day, range 5.3-12.0). Peak serum cortisol concentration was higher in children compared with adults, whereas nadir serum cortisol concentrations were similar. Timing of the peak serum cortisol concentration was similar (07.05-07.25), whereas that of the nadir concentration occurred later in adults (midnight) compared with children (22.48) (P = 0.003). Children had the highest percentage of cortisol secretion between 06.00 and 12.00 (38.4%), whereas in adults this took place between midnight and 06.00 (45.2%). These observations suggest that the daily hydrocortisone replacement dose should be equivalent on average to 6.3 mg/m(2) body surface area/day in adults and 8.0 mg/m(2) body surface area/day in children. Differences in distribution of the total daily dose between older adults and young children need to be taken into account when using a three or four times per day dosing regimen. © 2012 Blackwell Publishing Ltd.

  10. Radiation dosimetry predicts IQ after conformal radiation therapy in pediatric patients with localized ependymoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merchant, Thomas E.; Kiehna, Erin N.; Li Chenghong

    2005-12-01

    Purpose: To assess the effects of radiation dose-volume distribution on the trajectory of IQ development after conformal radiation therapy (CRT) in pediatric patients with ependymoma. Methods and Materials: The study included 88 patients (median age, 2.8 years {+-} 4.5 years) with localized ependymoma who received CRT (54-59.4 Gy) that used a 1-cm margin on the postoperative tumor bed. Patients were evaluated with tests that included IQ measures at baseline (before CRT) and at 6, 12, 24, 36, 48, and 60 months. Differential dose-volume histograms (DVH) were derived for total-brain, supratentorial-brain, and right and left temporal-lobe volumes. The data were partitionedmore » into three dose intervals and integrated to create variables that represent the fractional volume that received dose over the specified intervals (e.g., V{sub 0-20Gy}, V{sub 20-40Gy}, V{sub 40-65Gy}) and modeled with clinical variables to develop a regression equation to estimate IQ after CRT. Results: A total of 327 IQ tests were performed in 66 patients with infratentorial tumors and 20 with supratentorial tumors. The median follow-up was 29.4 months. For all patients, IQ was best estimated by age (years) at CRT; percent volume of the supratentorial brain that received doses between 0 and 20 Gy, 20 and 40 Gy, and 40 and 65 Gy; and time (months) after CRT. Age contributed significantly to the intercept (p > 0.0001), and the dose-volume coefficients were statistically significant (V{sub 0-20Gy}, p = 0.01; V{sub 20-40Gy}, p < 0.001; V{sub 40-65Gy}, p = 0.04). A similar model was developed exclusively for patients with infratentorial tumors but not supratentorial tumors. Conclusion: Radiation dosimetry can be used to predict IQ after CRT in patients with localized ependymoma. The specificity of models may be enhanced by grouping according to tumor location.« less

  11. An international dosimetry exchange for boron neutron capture therapy. Part I: Absorbed dose measurements.

    PubMed

    Binns, P J; Riley, K J; Harling, O K; Kiger, W S; Munck af Rosenschöld, P M; Giusti, V; Capala, J; Sköld, K; Auterinen, I; Serén, T; Kotiluoto, P; Uusi-Simola, J; Marek, M; Viererbl, L; Spurny, F

    2005-12-01

    An international collaboration was organized to undertake a dosimetry exchange to enable the future combination of clinical data from different centers conducting neutron capture therapy trials. As a first step (Part I) the dosimetry group from the Americas, represented by MIT, visited the clinical centers at Studsvik (Sweden), VTT Espoo (Finland), and the Nuclear Research Institute (NRI) at Rez (Czech Republic). A combined VTT/NRI group reciprocated with a visit to MIT. Each participant performed a series of dosimetry measurements under equivalent irradiation conditions using methods appropriate to their clinical protocols. This entailed in-air measurements and dose versus depth measurements in a large water phantom. Thermal neutron flux as well as fast neutron and photon absorbed dose rates were measured. Satisfactory agreement in determining absorbed dose within the experimental uncertainties was obtained between the different groups although the measurement uncertainties are large, ranging between 3% and 30% depending upon the dose component and the depth of measurement. To improve the precision in the specification of absorbed dose amongst the participants, the individually measured dose components were normalized to the results from a single method. Assuming a boron concentration of 15 microg g(-1) that is typical of concentrations realized clinically with the boron delivery compound boronophenylalanine-fructose, systematic discrepancies in the specification of the total biologically weighted dose of up to 10% were apparent between the different groups. The results from these measurements will be used in future to normalize treatment plan calculations between the different clinical dosimetry protocols as Part II of this study.

  12. Pulmonary Artery Invasion, High-Dose Radiation, and Overall Survival in Patients With Non-Small Cell Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, Cheng-Bo; Department of Oncology, Shengjing Hospital of China Medical University, Shenyang; Wang, Wei-Li

    2014-06-01

    Purpose: To investigate whether high-dose radiation to the pulmonary artery (PA) affects overall survival (OS) in patients with non-small cell lung cancer (NSCLC). Methods and Materials: Patients with medically inoperable/unresectable NSCLC treated with definitive radiation therapy in prospective studies were eligible for this study. Pulmonary artery involvement was defined on the basis of pretreatment chest CT and positron emission tomography/CT fusion. Pulmonary artery was contoured according to the Radiation Therapy Oncology Group protocol 1106 atlas, and dose-volume histograms were generated. Results: A total of 100 patients with a minimum follow-up of 1 year for surviving patients were enrolled: 82.0% underwent concurrentmore » chemoradiation therapy. Radiation dose ranged from 60 to 85.5 Gy in 30-37 fractions. Patients with PA invasion of grade ≤2, 3, 4, and 5 had 1-year OS and median survival of 67% and 25.4 months (95% confidence interval [CI] 15.7-35.1), 62% and 22.2 months (95% CI 5.8-38.6), 90% and 35.8 months (95% CI 28.4-43.2), and 50% and 7.0 months, respectively (P=.601). Two of the 4 patients with grade 5 PA invasion died suddenly from massive hemorrhage at 3 and 4.5 months after completion of radiation therapy. Maximum and mean doses to PA were not significantly associated with OS. The V45, V50, V55, and V60 of PA were correlated significantly with a worse OS (P<.05). Patients with V45 >70% or V60 >37% had significantly worse OS (13.3 vs 37.9 months, P<.001, and 13.8 vs 37.9 months, P=.04, respectively). Conclusions: Grade 5 PA invasion and PA volume receiving more than 45-60 Gy may be associated with inferior OS in patients with advanced NSCLC treated with concurrent chemoradiation.« less

  13. Cardiac Exposure in the Dynamic Conformal Arc Therapy, Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy of Lung Cancer

    PubMed Central

    Ming, Xin; Feng, Yuanming; Liu, Huan; Zhang, Ying; Zhou, Li; Deng, Jun

    2015-01-01

    Purpose To retrospectively evaluate the cardiac exposure in three cohorts of lung cancer patients treated with dynamic conformal arc therapy (DCAT), intensity-modulated radiotherapy (IMRT), or volumetric modulated arc therapy (VMAT) at our institution in the past seven years. Methods and Materials A total of 140 lung cancer patients were included in this institutional review board approved study: 25 treated with DCAT, 70 with IMRT and 45 with VMAT. All plans were generated in a same commercial treatment planning system and have been clinically accepted and delivered. The dose distribution to the heart and the effects of tumor laterality, the irradiated heart volume and the beam-to-heart distance on the cardiac exposure were investigated. Results The mean dose to the heart among all 140 plans was 4.5 Gy. Specifically, the heart received on average 2.3, 5.2 and 4.6 Gy in the DCAT, IMRT and VMAT plans, respectively. The mean heart doses for the left and right lung tumors were 4.1 and 4.8 Gy, respectively. No patients died with evidence of cardiac disease. Three patients (2%) with preexisting cardiac condition developed cardiac disease after treatment. Furthermore, the cardiac exposure was found to increase linearly with the irradiated heart volume while decreasing exponentially with the beam-to-heart distance. Conclusions Compared to old technologies for lung cancer treatment, modern radiotherapy treatment modalities demonstrated better heart sparing. But the heart dose in lung cancer radiotherapy is still higher than that in the radiotherapy of breast cancer and Hodgkin’s disease where cardiac complications have been extensively studied. With strong correlations of mean heart dose with beam-to-heart distance and irradiated heart volume, cautions should be exercised to avoid long-term cardiac toxicity in the lung cancer patients undergoing radiotherapy. PMID:26630566

  14. The Effect of Ezetimibe/Statin Combination and High-Dose Statin Therapy on Thyroid Autoimmunity in Women with Hashimoto's Thyroiditis and Cardiovascular Disease: A Pilot Study.

    PubMed

    Krysiak, R; Szkróbka, W; Okopień, B

    2016-10-01

    Background: Intensive statin therapy was found to reduce thyroid autoimmunity in women with Hashimoto's thyroiditis. No similar data are available for other hypolipidemic agents. Methods: The participants of the study were 16 women with Hashimoto's thyroiditis and coronary artery disease. On the basis of statin tolerance, they were divided into 2 groups. 8 patients who did not tolerate high-dose statin therapy were treated with a statin, the dose of which was reduced by half, together with ezetimibe. The remaining 8 patients tolerating the treatment continued high-dose statin therapy. Plasma lipids, serum levels of thyrotropin, free thyroxine and free triiodothyronine, as well as titers of thyroid peroxidase and thyroglobulin antibodies were measured at the beginning of the study and 6 months later. Results: Replacing high-dose statin therapy with ezetimibe/statin combination therapy increased serum titers of thyroid peroxidase as well as led to an insignificant increase in serum titers of thyroglobulin antibodies. At the end of the study, thyroid peroxidase and thyroglobulin antibody titers were higher in patients receiving the combination therapy than in those treated only with high-dose statin. Conclusions: Our study shows that high-dose statin therapy produces a stronger effect on thyroid autoimmunity than ezetimibe/statin combination therapy. © Georg Thieme Verlag KG Stuttgart · New York.

  15. A stochastic approach to estimate the uncertainty of dose mapping caused by uncertainties in b-spline registration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hub, Martina; Thieke, Christian; Kessler, Marc L.

    2012-04-15

    Purpose: In fractionated radiation therapy, image guidance with daily tomographic imaging becomes more and more clinical routine. In principle, this allows for daily computation of the delivered dose and for accumulation of these daily dose distributions to determine the actually delivered total dose to the patient. However, uncertainties in the mapping of the images can translate into errors of the accumulated total dose, depending on the dose gradient. In this work, an approach to estimate the uncertainty of mapping between medical images is proposed that identifies areas bearing a significant risk of inaccurate dose accumulation. Methods: This method accounts formore » the geometric uncertainty of image registration and the heterogeneity of the dose distribution, which is to be mapped. Its performance is demonstrated in context of dose mapping based on b-spline registration. It is based on evaluation of the sensitivity of dose mapping to variations of the b-spline coefficients combined with evaluation of the sensitivity of the registration metric with respect to the variations of the coefficients. It was evaluated based on patient data that was deformed based on a breathing model, where the ground truth of the deformation, and hence the actual true dose mapping error, is known. Results: The proposed approach has the potential to distinguish areas of the image where dose mapping is likely to be accurate from other areas of the same image, where a larger uncertainty must be expected. Conclusions: An approach to identify areas where dose mapping is likely to be inaccurate was developed and implemented. This method was tested for dose mapping, but it may be applied in context of other mapping tasks as well.« less

  16. A stochastic approach to estimate the uncertainty of dose mapping caused by uncertainties in b-spline registration

    PubMed Central

    Hub, Martina; Thieke, Christian; Kessler, Marc L.; Karger, Christian P.

    2012-01-01

    Purpose: In fractionated radiation therapy, image guidance with daily tomographic imaging becomes more and more clinical routine. In principle, this allows for daily computation of the delivered dose and for accumulation of these daily dose distributions to determine the actually delivered total dose to the patient. However, uncertainties in the mapping of the images can translate into errors of the accumulated total dose, depending on the dose gradient. In this work, an approach to estimate the uncertainty of mapping between medical images is proposed that identifies areas bearing a significant risk of inaccurate dose accumulation. Methods: This method accounts for the geometric uncertainty of image registration and the heterogeneity of the dose distribution, which is to be mapped. Its performance is demonstrated in context of dose mapping based on b-spline registration. It is based on evaluation of the sensitivity of dose mapping to variations of the b-spline coefficients combined with evaluation of the sensitivity of the registration metric with respect to the variations of the coefficients. It was evaluated based on patient data that was deformed based on a breathing model, where the ground truth of the deformation, and hence the actual true dose mapping error, is known. Results: The proposed approach has the potential to distinguish areas of the image where dose mapping is likely to be accurate from other areas of the same image, where a larger uncertainty must be expected. Conclusions: An approach to identify areas where dose mapping is likely to be inaccurate was developed and implemented. This method was tested for dose mapping, but it may be applied in context of other mapping tasks as well. PMID:22482640

  17. Thyroid and hepatic function after high-dose 131 I-metaiodobenzylguanidine (131 I-MIBG) therapy for neuroblastoma.

    PubMed

    Quach, Alekist; Ji, Lingyun; Mishra, Vikash; Sznewajs, Aimee; Veatch, Janet; Huberty, John; Franc, Benjamin; Sposto, Richard; Groshen, Susan; Wei, Denice; Fitzgerald, Paul; Maris, John M; Yanik, Gregory; Hawkins, Randall A; Villablanca, Judith G; Matthay, Katherine K

    2011-02-01

    (131) I-Metaiodobenzylguanidine ((131) I-MIBG) provides targeted radiotherapy for children with neuroblastoma, a malignancy of the sympathetic nervous system. Dissociated radioactive iodide may concentrate in the thyroid, and (131) I-MIBG is concentrated in the liver after (131) I-MIBG therapy. The aim of our study was to analyze the effects of (131) I-MIBG therapy on thyroid and liver function. Pre- and post-therapy thyroid and liver functions were reviewed in a total of 194 neuroblastoma patients treated with (131) I-MIBG therapy. The cumulative incidence over time was estimated for both thyroid and liver toxicities. The relationship to cumulative dose/kg, number of treatments, time from treatment to follow-up, sex, and patient age was examined. In patients who presented with Grade 0 or 1 thyroid toxicity at baseline, 12  ±  4% experienced onset of or worsening to Grade 2 hypothyroidism and one patient developed Grade 2 hyperthyroidism by 2 years after (131) I-MIBG therapy. At 2 years post-(131) I-MIBG therapy, 76  ±  4% patients experienced onset or worsening of hepatic toxicity to any grade, and 23  ±  5% experienced onset of or worsening to Grade 3 or 4 liver toxicity. Liver toxicity was usually transient asymptomatic transaminase elevation, frequently confounded by disease progression and other therapies. The prophylactic regimen of potassium iodide and potassium perchlorate with (131) I-MIBG therapy resulted in a low rate of significant hypothyroidism. Liver abnormalities following (131) I-MIBG therapy were primarily reversible and did not result in late toxicity. (131) I-MIBG therapy is a promising treatment for children with relapsed neuroblastoma with a relatively low rate of symptomatic thyroid or hepatic dysfunction. Copyright © 2010 Wiley-Liss, Inc.

  18. TU-EF-304-07: Monte Carlo-Based Inverse Treatment Plan Optimization for Intensity Modulated Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Y; UT Southwestern Medical Center, Dallas, TX; Tian, Z

    2015-06-15

    Purpose: Intensity-modulated proton therapy (IMPT) is increasingly used in proton therapy. For IMPT optimization, Monte Carlo (MC) is desired for spots dose calculations because of its high accuracy, especially in cases with a high level of heterogeneity. It is also preferred in biological optimization problems due to the capability of computing quantities related to biological effects. However, MC simulation is typically too slow to be used for this purpose. Although GPU-based MC engines have become available, the achieved efficiency is still not ideal. The purpose of this work is to develop a new optimization scheme to include GPU-based MC intomore » IMPT. Methods: A conventional approach using MC in IMPT simply calls the MC dose engine repeatedly for each spot dose calculations. However, this is not the optimal approach, because of the unnecessary computations on some spots that turned out to have very small weights after solving the optimization problem. GPU-memory writing conflict occurring at a small beam size also reduces computational efficiency. To solve these problems, we developed a new framework that iteratively performs MC dose calculations and plan optimizations. At each dose calculation step, the particles were sampled from different spots altogether with Metropolis algorithm, such that the particle number is proportional to the latest optimized spot intensity. Simultaneously transporting particles from multiple spots also mitigated the memory writing conflict problem. Results: We have validated the proposed MC-based optimization schemes in one prostate case. The total computation time of our method was ∼5–6 min on one NVIDIA GPU card, including both spot dose calculation and plan optimization, whereas a conventional method naively using the same GPU-based MC engine were ∼3 times slower. Conclusion: A fast GPU-based MC dose calculation method along with a novel optimization workflow is developed. The high efficiency makes it attractive for clinical usages.« less

  19. SU-E-T-567: Neutron Dose Equivalent Evaluation for Pencil Beam Scanning Proton Therapy with Apertures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geng, C; Nanjing University of Aeronautics and Astronautics, Nanjing; Schuemann, J

    Purpose: To determine the neutron contamination from the aperture in pencil beam scanning during proton therapy. Methods: A Monte Carlo based proton therapy research platform TOPAS and the UF-series hybrid pediatric phantoms were used to perform this study. First, pencil beam scanning (PBS) treatment pediatric plans with average spot size of 10 mm at iso-center were created and optimized for three patients with and without apertures. Then, the plans were imported into TOPAS. A scripting method was developed to automatically replace the patient CT with a whole body phantom positioned according to the original plan iso-center. The neutron dose equivalentmore » was calculated using organ specific quality factors for two phantoms resembling a 4- and 14-years old patient. Results: The neutron dose equivalent generated by the apertures in PBS is 4–10% of the total neutron dose equivalent for organs near the target, while roughly 40% for organs far from the target. Compared to the neutron dose equivalent caused by PBS without aperture, the results show that the neutron dose equivalent with aperture is reduced in the organs near the target, and moderately increased for those organs located further from the target. This is due to the reduction of the proton dose around the edge of the CTV, which causes fewer neutrons generated in the patient. Conclusion: Clinically, for pediatric patients, one might consider adding an aperture to get a more conformal treatment plan if the spot size is too large. This work shows the somewhat surprising fact that adding an aperture for beam scanning for facilities with large spot sizes reduces instead of increases a potential neutron background in regions near target. Changran Geng is supported by the Chinese Scholarship Council (CSC) and the National Natural Science Foundation of China (Grant No. 11475087)« less

  20. Opioid analgesia in mechanically ventilated children: results from the multicenter Measuring Opioid Tolerance Induced by Fentanyl study.

    PubMed

    Anand, Kanwaljeet J S; Clark, Amy E; Willson, Douglas F; Berger, John; Meert, Kathleen L; Zimmerman, Jerry J; Harrison, Rick; Carcillo, Joseph A; Newth, Christopher J L; Bisping, Stephanie; Holubkov, Richard; Dean, J Michael; Nicholson, Carol E

    2013-01-01

    To examine the clinical factors associated with increased opioid dose among mechanically ventilated children in the pediatric intensive care unit. Prospective, observational study with 100% accrual of eligible patients. Seven pediatric intensive care units from tertiary-care children's hospitals in the Collaborative Pediatric Critical Care Research Network. Four hundred nineteen children treated with morphine or fentanyl infusions. None. Data on opioid use, concomitant therapy, demographic and explanatory variables were collected. Significant variability occurred in clinical practices, with up to 100-fold differences in baseline opioid doses, average daily or total doses, or peak infusion rates. Opioid exposure for 7 or 14 days required doubling of the daily opioid dose in 16% patients (95% confidence interval 12%-19%) and 20% patients (95% confidence interval 16%-24%), respectively. Among patients receiving opioids for longer than 3 days (n = 225), this occurred in 28% (95% confidence interval 22%-33%) and 35% (95% confidence interval 29%-41%) by 7 or 14 days, respectively. Doubling of the opioid dose was more likely to occur following opioid infusions for 7 days or longer (odds ratio 7.9, 95% confidence interval 4.3-14.3; p < 0.001) or co-therapy with midazolam (odds ratio 5.6, 95% confidence interval 2.4-12.9; p < 0.001), and it was less likely to occur if morphine was used as the primary opioid (vs. fentanyl) (odds ratio 0.48, 95% confidence interval 0.25-0.92; p = 0.03), for patients receiving higher initial doses (odds ratio 0.96, 95% confidence interval 0.95-0.98; p < 0.001), or if patients had prior pediatric intensive care unit admissions (odds ratio 0.37, 95% confidence interval 0.15-0.89; p = 0.03). Mechanically ventilated children require increasing opioid doses, often associated with prolonged opioid exposure or the need for additional sedation. Efforts to reduce prolonged opioid exposure and clinical practice variation may prevent the complications of opioid therapy.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, M; Pompos, A; Gu, X

    Purpose: To characterize the dose distributions of Cyberknife and intensity-modulated-proton-therapy (IMPT). Methods: A total of 20 patients previously treated with Cyberknife were selected. The original planning-target-volume (PTV) was used in the ‘IMPT-ideal’ plan assuming a comparable image-guidance with Cyberknife. A 3mm expansion was made to create the proton-PTV for the ‘IMPT-3mm’ plan representing the current proton-therapy where a margin of 3mm is used to account for the inferior image-guidance. The proton range uncertainty was taken-care in beam-design by adding the proximal- and distal-margins (3%water-equivalent-depth+1mm) for both proton plans. The IMPT plans were generated to meet the same target coverage asmore » the Cyberknife-plans. The plan quality of IMPT-ideal and IMPT-3mm were compared to the Cyberknife-plan. To characterize plan quality, we defined the ratio(R) of volumes encompassed by the selected isodose surfaces for Cyberknife and IMPT plans (VCK/VIMPT). Comparisons were made for both Cyberknife versus IMPT-ideal and Cyberknife versusIMPT-3mm to further discuss the impact of setup error margins used in proton therapy and the correlation with target size and location. Results: IMPT-ideal plans yield comparable plan quality as CK plans and slightly better OAR sparing while the IMPT-3mm plan results in a higher dose to the OARs, especially for centralized tumors. Comparing to the IMPT-ideal plans, a slightly larger 80% (Ravg=1.05) dose cloud and significantly larger 50% (Ravg=1.3) and 20% (Ravg=1.60) dose clouds are seen in CK plans. However, the 3mm expansion results in a larger high and medium dose clouds in IMPT-3mm plans (Ravg=0.65 for 80%-isodose; Ravg=0.93 for 50%-isodose). The trend increases with the size of the target and the distance from the brainstem to the center of target. Conclusion: Cyberknife is more preferable for treating centralized targets and proton therapy is advantageous for the large and peripheral targets. Advanced image guidance would improve the efficacy of proton therapy for intracranial treatments.« less

  2. [Optimization of enuresis therapy in children using transcranial magnetotherapy].

    PubMed

    Otpushchennikova, T V; Kazanskaia, I V; Volkov, S V; Raĭgorodskaia, Iu M

    2010-01-01

    A total of 58 children (age from 6 to 14 years) suffering from nocturnal enuresis (NE) were divided into two groups. The study group received basic therapy (driptan dose was reduced to 2.5 mg twice a day) in combination with transcranial bitemporal magnetotherapy (TcMT). The control group received placebo TcMT and basic therapy. It is shown that addition of TcMT to reduced basic therapy lowered the score of imperative voiding symptoms 1.3-fold, number of enuresis patients 1.7-fold, volume of the bladder 6.8 months after the treatment 1.9-fold, corrected vegetative status and activity of the subcortical nervous center in 24% children according to cardiointervalography versus the controls. Thus, TcMT improves clinical effect in NE patients in 2-fold reduction of pharmacological burden.

  3. Salvage image guided radiation therapy to the prostate after cryotherapy failure.

    PubMed

    Hopper, Austin B; Sandhu, Ajay P S; Parsons, J Kellogg; Rose, Brent; Einck, John P

    2018-01-01

    Cryotherapy is an option for the primary treatment of localized prostate cancer, along with radical prostatectomy, external beam radiation therapy, and brachytherapy. Although it is known that local recurrence can occur in >20% of patients treated with primary cryotherapy, unfortunately there is a paucity of data on later salvage treatments. The use of external beam radiation therapy is an attractive option after cryotherapy failure, but there is little data on its efficacy and toxicity. We evaluated the biochemical control and complication rates of salvage dose-escalated image guided intensity modulated radiation therapy (IG-IMRT) after cryotherapy failure. Patients who were treated at our institution from 2005 to 2016 were reviewed for those who underwent cryotherapy as initial treatment followed by salvage IGRT. Patients were treated with dose-escalated IG-IMRT using standard treatment margins of 3 mm posterior and 7 mm in all other directions and daily cone beam computed tomography or kv imaging to implanted fiducial markers. Biochemical progression was defined in accordance with the Phoenix consensus conference definition. Eight patients were identified as having received post-cryotherapy salvage radiation within the study period. The median total dose was 77.7 Gy (range, 75.6-81.0 Gy). Median follow-up was 55 months (range, 6-88 months). Six patients remained biochemically controlled at the latest follow-up. One patient developed distant metastases after 22 months and one experienced biochemical failure at 30 months with no evidence of distant metastases. No patients experienced acute gastrointestinal toxicities of grade 2 or higher. There were no cases of late gastrointestinal or genitourinary toxicity. High-dose IG-IMRT results in high rates of salvage and extremely low rates of serious late toxicity for patients with locally recurrent prostate cancer after cryotherapy. Although the results are encouraging, given the small number of patients in this and other series, we remain cautious with regard to this treatment and believe the use of salvage radiation therapy after cryotherapy warrants further study.

  4. PSA Response to Neoadjuvant Androgen Deprivation Therapy Is a Strong Independent Predictor of Survival in High-Risk Prostate Cancer in the Dose-Escalated Radiation Therapy Era

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGuire, Sean E., E-mail: semcguir@mdanderson.org; Department of Molecular and Cellular Biology, Baylor College of Medicine, Houston, Texas; Lee, Andrew K.

    2013-01-01

    Purpose: The aim of the study was to evaluate the prognostic value of prostate-specific antigen (PSA) response to neoadjuvant androgen deprivation therapy (ADT) prior to dose-escalated radiation therapy (RT) and long-term ADT in high-risk prostate cancer. Methods and Materials: We reviewed the charts of all patients diagnosed with high-risk prostate cancer and treated with a combination of long-term ADT (median, 24 months) and dose-escalated (median, 75.6 Gy) RT between 1990 and 2007. The associations among patient, tumor, and treatment characteristics with biochemical response to neoadjuvant ADT and their effects on failure-free survival (FFS), time to distant metastasis (TDM), prostate cancer-specificmore » mortality (PCSM) and overall survival (OS) were examined. Results: A total of 196 patients met criteria for inclusion. Median follow-up time for patients alive at last contact was 7.0 years (range, 0.5-18.1 years). Multivariate analysis identified the pre-RT PSA concentration (<0.5 vs {>=}0.5 ng/mL) as a significant independent predictor of FFS (P=.021), TDM (P=.009), PCSM (P=.039), and OS (P=.037). On multivariate analysis, pretreatment PSA (iPSA) and African-American race were significantly associated with failure to achieve a pre-RT PSA of <0.5 ng/mL. Conclusions: For high-risk prostate cancer patients treated with long-term ADT and dose-escalated RT, a pre-RT PSA level {>=}0.5 ng/mL after neoadjuvant ADT predicts for worse survival measures. Both elevated iPSA and African-American race are associated with increased risk of having a pre-RT PSA level {>=}0.5 ng/mL. These patients should be considered for clinical trials that test newer, more potent androgen-depleting therapies such as abiraterone and MDV3100 in combination with radiation.« less

  5. Dose determinants in continuous renal replacement therapy.

    PubMed

    Clark, William R; Turk, Joseph E; Kraus, Michael A; Gao, Dayong

    2003-09-01

    Increasing attention is being paid to quantifying the dose of dialysis prescribed and delivered to critically ill patients with acute renal failure (ARF). Recent trials in both the intermittent hemodialysis (IHD) and continuous renal replacement therapy (CRRT) realms have suggested that a direct relationship between dose and survival exists for both of these therapies. The purpose of this review, first, is to analyze critically the above-mentioned dose/outcome studies in acute dialysis. Subsequently, the factors influencing dose prescription and delivery are discussed, with the focus on continuous venovenous hemofiltration (CVVH). Specifically, differences between postdilution and predilution CVVH will be highlighted, and the importance of blood flow rate in dose delivery for these therapies will be discussed.

  6. Medical intelligence in Sweden. Vitamin B12: oral compared with parenteral?

    PubMed

    Nilsson, M; Norberg, B; Hultdin, J; Sandström, H; Westman, G; Lökk, J

    2005-03-01

    Sweden is the only country in which oral high dose vitamin B12 has gained widespread use in the treatment of deficiency states. The aim of the study was to describe prescribing patterns and sales statistics of vitamin B12 tablets and injections in Sweden 1990-2000.Design, setting, and sources: Official statistics of cobalamin prescriptions and sales were used. The use of vitamin B12 increased in Sweden 1990-2000, mainly because of an increase in the use of oral high dose vitamin B12 therapy. The experience, in statistical terms a "total investigation", comprised 1,000,000 patient years for tablets and 750,000 patient years for injections. During 2000, 13% of residents aged 70 and over were treated with vitamin B12, two of three with the tablet preparation. Most patients in Sweden requiring vitamin B12 therapy have transferred from parenteral to oral high dose vitamin B12 since 1964, when the oral preparation was introduced. The findings suggest that many patients in other post-industrial societies may also be suitable for oral vitamin B12 treatment.

  7. Development of a new multi-modal Monte-Carlo radiotherapy planning system.

    PubMed

    Kumada, H; Nakamura, T; Komeda, M; Matsumura, A

    2009-07-01

    A new multi-modal Monte-Carlo radiotherapy planning system (developing code: JCDS-FX) is under development at Japan Atomic Energy Agency. This system builds on fundamental technologies of JCDS applied to actual boron neutron capture therapy (BNCT) trials in JRR-4. One of features of the JCDS-FX is that PHITS has been applied to particle transport calculation. PHITS is a multi-purpose particle Monte-Carlo transport code. Hence application of PHITS enables to evaluate total doses given to a patient by a combined modality therapy. Moreover, JCDS-FX with PHITS can be used for the study of accelerator based BNCT. To verify calculation accuracy of the JCDS-FX, dose evaluations for neutron irradiation of a cylindrical water phantom and for an actual clinical trial were performed, then the results were compared with calculations by JCDS with MCNP. The verification results demonstrated that JCDS-FX is applicable to BNCT treatment planning in practical use.

  8. The modulation of corticosteroid metabolism by hydrocortisone therapy in patients with hypopituitarism increases tissue glucocorticoid exposure.

    PubMed

    Sherlock, Mark; Behan, Lucy Ann; Hannon, Mark J; Alonso, Aurora Aragon; Thompson, Christopher J; Murray, Robert D; Crabtree, Nicola; Hughes, Beverly A; Arlt, Wiebke; Agha, Amar; Toogood, Andrew A; Stewart, Paul M

    2015-11-01

    Patients with hypopituitarism have increased morbidity and mortality. There is ongoing debate about the optimum glucocorticoid (GC) replacement therapy. To assess the effect of GC replacement in hypopituitarism on corticosteroid metabolism and its impact on body composition. We assessed the urinary corticosteroid metabolite profile (using gas chromatography/mass spectrometry) and body composition (clinical parameters and full body DXA) of 53 patients (19 female, median age 46 years) with hypopituitarism (33 ACTH-deficient/20 ACTH-replete) (study A). The corticosteroid metabolite profile of ten patients with ACTH deficiency was then assessed prospectively in a cross over study using three hydrocortisone (HC) dosing regimens (20/10 mg, 10/10 mg and 10/5 mg) (study B) each for 6 weeks. 11 beta-hydroxysteroid dehydrogenase 1 (11β-HSD1) activity was assessed by urinary THF+5α-THF/THE. Endocrine Centres within University Teaching Hospitals in the UK and Ireland. Urinary corticosteroid metabolite profile and body composition assessment. In study A, when patients were divided into three groups - patients not receiving HC and patients receiving HC≤20 mg/day or HC>20 mg/day - patients in the group receiving the highest daily dose of HC had significantly higher waist-to-hip ratio (WHR) than the ACTH replete group. They also had significantly elevated THF+5α-THF/THE (P=0.0002) and total cortisol metabolites (P=0.015). In study B, patients on the highest HC dose had significantly elevated total cortisol metabolites and all patients on HC had elevated THF+5α-THF/THE ratios when compared to controls. In ACTH-deficient patients daily HC doses of >20 mg/day have increased WHR, THF+5α-THF/THE ratios and total cortisol metabolites. GC metabolism and induction of 11β-HSD1 may play a pivitol role in the development of the metabolically adverse hypopituitary phenotype. © 2015 European Society of Endocrinology.

  9. Impact of Dose to the Bladder Trigone on Long-Term Urinary Function After High-Dose Intensity Modulated Radiation Therapy for Localized Prostate Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghadjar, Pirus; Zelefsky, Michael J.; Spratt, Daniel E.

    2014-02-01

    Purpose: To determine the potential association between genitourinary (GU) toxicity and planning dose–volume parameters for GU pelvic structures after high-dose intensity modulated radiation therapy in localized prostate cancer patients. Methods and Materials: A total of 268 patients who underwent intensity modulated radiation therapy to a prescribed dose of 86.4 Gy in 48 fractions during June 2004-December 2008 were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Dose–volume histograms of the whole bladder, bladder wall, urethra, and bladder trigone were analyzed. The primary endpoint for GU toxicity was an IPSS sum increase ≥10 points over baseline. Univariate and multivariate analysesmore » were done by the Kaplan-Meier method and Cox proportional hazard models, respectively. Results: Median follow-up was 5 years (range, 3-7.7 years). Thirty-nine patients experienced an IPSS sum increase ≥10 during follow-up; 84% remained event free at 5 years. After univariate analysis, lower baseline IPSS sum (P=.006), the V90 of the trigone (P=.006), and the maximal dose to the trigone (P=.003) were significantly associated with an IPSS sum increase ≥10. After multivariate analysis, lower baseline IPSS sum (P=.009) and increased maximal dose to the trigone (P=.005) remained significantly associated. Seventy-two patients had both a lower baseline IPSS sum and a higher maximal dose to the trigone and were defined as high risk, and 68 patients had both a higher baseline IPSS sum and a lower maximal dose to the trigone and were defined as low risk for development of an IPSS sum increase ≥10. Twenty-one of 72 high-risk patients (29%) and 5 of 68 low-risk patients (7%) experienced an IPSS sum increase ≥10 (P=.001; odds ratio 5.19). Conclusions: The application of hot spots to the bladder trigone was significantly associated with relevant changes in IPSS during follow-up. Reduction of radiation dose to the lower bladder and specifically the bladder trigone seems to be associated with a reduction in late GU toxicity.« less

  10. COMPARTMENTALIZED PHANTOMS FOR THE STANDARD MAN, ADOLESCENT AND CHILD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hayes, R.L.; Brucer, M.

    A compartmentalized phantom for the standard man was designed and built of readily available and inexpensive materials. Similar phantoms were also designed for an adolescent and a child. The basic emphasis in the designs is on general utility so that a variety of different dosemeasurement techniques could be used on the same phantom. The designs are, however, in reasonable agreement with authropometric data reported in the literature. The phantoms proved to be extremely useful in depth-dose and energy-absorption measurements for total-body irradiation therapy. Dose measurements with beam teletherapy, brachytherapy devices, and internally distributed radioisotopes were also made. (auth)

  11. Real-time optical fiber dosimeter probe

    NASA Astrophysics Data System (ADS)

    Croteau, André; Caron, Serge; Rink, Alexandra; Jaffray, David; Mermut, Ozzy

    2011-03-01

    There is a pressing need for a passive optical fiber dosimeter probe for use in real-time monitoring of radiation dose delivered to clinical radiation therapy patients. An optical fiber probe using radiochromic material has been designed and fabricated based on a thin film of the radiochromic material on a dielectric mirror. Measurements of the net optical density vs. time before, during, and after irradiation at a rate of 500cGy/minute to a total dose of 5 Gy were performed. Net optical densities increased from 0.2 to 2.0 for radiochromic thin film thicknesses of 2 to 20 μm, respectively.

  12. An in-depth Monte Carlo study of lateral electron disequilibrium for small fields in ultra-low density lung: implications for modern radiation therapy

    NASA Astrophysics Data System (ADS)

    Disher, Brandon; Hajdok, George; Gaede, Stewart; Battista, Jerry J.

    2012-03-01

    Modern radiation therapy techniques such as intensity-modulated radiation therapy (IMRT) and stereotactic body radiation therapy (SBRT) use tightly conformed megavoltage x-ray fields to irradiate a tumour within lung tissue. For these conditions, lateral electron disequilibrium (LED) may occur, which systematically perturbs the dose distribution within tumour and nearby lung tissues. The goal of this work is to determine the combination of beam and lung density parameters that cause significant LED within and near the tumour. The Monte Carlo code DOSXYZnrc (National Research Council of Canada, Ottawa, ON) was used to simulate four 20 × 20 × 25 cm3 water-lung-water slab phantoms, which contained lung tissue only, or one of three different centrally located small tumours (sizes: 1 × 1 × 1, 3 × 3 × 3, 5 × 5 × 5 cm3). Dose calculations were performed using combinations of six beam energies (Co-60 up to 18 MV), five field sizes (1 × 1 cm2 up to 15 × 15 cm2), and 12 lung densities (0.001 g cm-3 up to 1 g cm-3) for a total of 1440 simulations. We developed the relative depth-dose factor (RDDF), which can be used to characterize the extent of LED (RDDF <1.0). For RDDF <0.7 severe LED occurred, and both lung and tumour dose were drastically reduced. For example, a 6 MV (3 × 3 cm2) field was used to irradiate a 1 cm3 tumour embedded in lung with ultra-low density of 0.001 g cm-3 (RDDF = 0.2). Dose in up-stream lung and tumour centre were reduced by as much as 80% with respect to the water density calculation. These reductions were worse for smaller tumours irradiated with high energy beams, small field sizes, and low lung density. In conclusion, SBRT trials based on dose calculations in homogeneous tissue are misleading as they do not reflect the actual dosimetric effects due to LED. Future clinical trials should only use dose calculation engines that can account for electron scatter, with special attention given to patients with low lung density (i.e. emphysema). In cases where tissue inhomogeneity corrections are applied, the nature of the correction used may be inadequate in predicting the correct level of LED. In either case, the dose to the tumour is not the prescribed dose and clinical response data are uncertain. The new information from this study can be used by radiation oncologists who wish to perform advanced radiation therapy techniques while avoiding the deleterious predictable dosimetric effects of LED.

  13. Cost-effectiveness of allopurinol and febuxostat for the management of gout.

    PubMed

    Jutkowitz, Eric; Choi, Hyon K; Pizzi, Laura T; Kuntz, Karen M

    2014-11-04

    Gout is the most common inflammatory arthritis in the United States. To evaluate the cost-effectiveness of urate-lowering treatment strategies for the management of gout. Markov model. Published literature and expert opinion. Patients for whom allopurinol or febuxostat is a suitable initial urate-lowering treatment. Lifetime. Health care payer. 5 urate-lowering treatment strategies were evaluated: no treatment; allopurinol- or febuxostat-only therapy; allopurinol-febuxostat sequential therapy; and febuxostat-allopurinol sequential therapy. Two dosing scenarios were investigated: fixed dose (80 mg of febuxostat daily, 0.80 success rate; 300 mg of allopurinol daily, 0.39 success rate) and dose escalation (≤120 mg of febuxostat daily, 0.82 success rate; ≤800 mg of allopurinol daily, 0.78 success rate). Discounted costs, discounted quality-adjusted life-years, and incremental cost-effectiveness ratios. In both dosing scenarios, allopurinol-only therapy was cost-saving. Dose-escalation allopurinol-febuxostat sequential therapy was more costly but more effective than dose-escalation allopurinol therapy, with an incremental cost-effectiveness ratio of $39 400 per quality-adjusted life-year. The relative rankings of treatments did not change. Our results were relatively sensitive to several potential variations of model assumptions; however, the cost-effectiveness ratios of dose escalation with allopurinol-febuxostat sequential therapy remained lower than the willingness-to-pay threshold of $109 000 per quality-adjusted life-year. Long-term outcome data for patients with gout, including medication adherence, are limited. Allopurinol single therapy is cost-saving compared with no treatment. Dose-escalation allopurinol-febuxostat sequential therapy is cost-effective compared with accepted willingness-to-pay thresholds. Agency for Healthcare Research and Quality.

  14. Definitive Reirradiation for Locoregionally Recurrent Non-Small Cell Lung Cancer With Proton Beam Therapy or Intensity Modulated Radiation Therapy: Predictors of High-Grade Toxicity and Survival Outcomes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McAvoy, Sarah; Ciura, Katherine; Wei, Caimiao

    2014-11-15

    Purpose: Intrathoracic recurrence of non-small cell lung cancer (NSCLC) after initial treatment remains a dominant cause of death. We report our experience using proton beam therapy and intensity modulated radiation therapy for reirradiation in such cases, focusing on patterns of failure, criteria for patient selection, and predictors of toxicity. Methods and Materials: A total of 102 patients underwent reirradiation for intrathoracic recurrent NSCLC at a single institution. All doses were recalculated to an equivalent dose in 2-Gy fractions (EQD2). All patients had received radiation therapy for NSCLC (median initial dose of 70 EQD2 Gy), with median interval to reirradiation ofmore » 17 months and median reirradiation dose of 60.48 EQD2 Gy. Median follow-up time was 6.5 months (range, 0-72 months). Results: Ninety-nine patients (97%) completed reirradiation. Median local failure-free survival, distant metastasis-free survival (DMFS), and overall survival times were 11.43 months (range, 8.6-22.66 months), 11.43 months (range, 6.83-23.84 months), and 14.71 (range, 10.34-20.56 months), respectively. Toxicity was acceptable, with rates of grade ≥3 esophageal toxicity of 7% and grade ≥3 pulmonary toxicity of 10%. Of the patients who developed local failure after reirradiation, 88% had failure in either the original or the reirradiation field. Poor local control was associated with T4 disease, squamous histology, and Eastern Cooperative Oncology Group performance status score >1. Concurrent chemotherapy improved DMFS, but T4 disease was associated with poor DMFS. Higher T status, Eastern Cooperative Oncology Group performance status ≥1, squamous histology, and larger reirradiation target volumes led to worse overall survival; receipt of concurrent chemotherapy and higher EQD2 were associated with improved OS. Conclusions: Intensity modulated radiation therapy and proton beam therapy are options for treating recurrent non-small cell lung cancer. However, rates of locoregional recurrence and distant metastasis are high, and patients should be selected carefully to maximize the benefit of additional aggressive local therapy while minimizing the risk of adverse side effects.« less

  15. Quasi-VMAT in high-grade glioma radiation therapy.

    PubMed

    Fadda, G; Massazza, G; Zucca, S; Durzu, S; Meleddu, G; Possanzini, M; Farace, P

    2013-05-01

    To compare a quasi-volumetric modulated arc therapy (qVMAT) with three-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT) for the treatment of high-grade gliomas. The qVMAT technique is a fast method of radiation therapy in which multiple equispaced beams analogous to those in rotation therapy are radiated in succession. This study included 12 patients with a planning target volume (PTV) that overlapped at least one organ at risk (OAR). 3D-CRT was planned using 2-3 non-coplanar beams, whereby the field-in-field technique (FIF) was used to divide each field into 1-3 subfields to shield the OAR. The qVMAT strategy was planned with 15 equispaced beams and IMRT was planned using 9 beams with a total of 80 segments. Inverse planning for qVMAT and IMRT was performed by direct machine parameter optimization (DMPO) to deliver a homogenous dose distribution of 60 Gy within the PTV and simultaneously limit the dose received by the OARs to the recommended values. Finally, the effect of introducing a maximum dose objective (max. dose < 54 Gy) for a virtual OAR in the form of a 0.5 cm ring around the PTV was investigated. The qVMAT method gave rise to significantly improved PTV95% and conformity index (CI) values in comparison to 3D-CRT (PTV95% = 90.7 % vs. 82.0 %; CI = 0.79 vs. 0.74, respectively). A further improvement was achieved by IMRT (PTV95% = 94.4 %, CI = 0.78). In qVMAT and IMRT, the addition of a 0.5 cm ring around the PTV produced a significant increase in CI (0.87 and 0.88, respectively), but dosage homogeneity within the PTV was considerably reduced (PTV95% = 88.5 % and 92.3 %, respectively). The time required for qVMAT dose delivery was similar to that required using 3D-CRT. These findings suggest that qVMAT should be preferred to 3D-CRT for the treatment of high-grade gliomas. The qVMAT method could be applied in hospitals, for example, which have limited departmental resources and are not equipped with systems capable of VMAT delivery.

  16. Tumor Volume Estimation and Quasi-Continuous Administration for Most Effective Bevacizumab Therapy

    PubMed Central

    Sápi, Johanna; Kovács, Levente; Drexler, Dániel András; Kocsis, Pál; Gajári, Dávid; Sápi, Zoltán

    2015-01-01

    Background Bevacizumab is an exogenous inhibitor which inhibits the biological activity of human VEGF. Several studies have investigated the effectiveness of bevacizumab therapy according to different cancer types but these days there is an intense debate on its utility. We have investigated different methods to find the best tumor volume estimation since it creates the possibility for precise and effective drug administration with a much lower dose than in the protocol. Materials and Methods We have examined C38 mouse colon adenocarcinoma and HT-29 human colorectal adenocarcinoma. In both cases, three groups were compared in the experiments. The first group did not receive therapy, the second group received one 200 μg bevacizumab dose for a treatment period (protocol-based therapy), and the third group received 1.1 μg bevacizumab every day (quasi-continuous therapy). Tumor volume measurement was performed by digital caliper and small animal MRI. The mathematical relationship between MRI-measured tumor volume and mass was investigated to estimate accurate tumor volume using caliper-measured data. A two-dimensional mathematical model was applied for tumor volume evaluation, and tumor- and therapy-specific constants were calculated for the three different groups. The effectiveness of bevacizumab administration was examined by statistical analysis. Results In the case of C38 adenocarcinoma, protocol-based treatment did not result in significantly smaller tumor volume compared to the no treatment group; however, there was a significant difference between untreated mice and mice who received quasi-continuous therapy (p = 0.002). In the case of HT-29 adenocarcinoma, the daily treatment with one-twelfth total dose resulted in significantly smaller tumors than the protocol-based treatment (p = 0.038). When the tumor has a symmetrical, solid closed shape (typically without treatment), volume can be evaluated accurately from caliper-measured data with the applied two-dimensional mathematical model. Conclusion Our results provide a theoretical background for a much more effective bevacizumab treatment using optimized administration. PMID:26540189

  17. A Multicenter Phase II Trial of S-1 With Concurrent Radiation Therapy for Locally Advanced Pancreatic Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ikeda, Masafumi, E-mail: masikeda@east.ncc.go.jp; Ioka, Tatsuya; Ito, Yoshinori

    2013-01-01

    Purpose: The aim of this trial was to evaluate the efficacy and toxicity of S-1 and concurrent radiation therapy for locally advanced pancreatic cancer (PC). Methods and Materials: Locally advanced PC patients with histologically or cytologically confirmed adenocarcinoma or adenosquamous carcinoma, who had no previous therapy were enrolled. Radiation therapy was delivered through 3 or more fields at a total dose of 50.4 Gy in 28 fractions over 5.5 weeks. S-1 was administered orally at a dose of 80 mg/m{sup 2} twice daily on the day of irradiation during radiation therapy. After a 2- to 8-week break, patients received amore » maintenance dose of S-1 (80 mg/m{sup 2}/day for 28 consecutive days, followed by a 14-day rest period) was then administered until the appearance of disease progression or unacceptable toxicity. The primary efficacy endpoint was survival, and the secondary efficacy endpoints were progression-free survival, response rate, and serum carbohydrate antigen 19-9 (CA19-9) response; the safety endpoint was toxicity. Results: Of the 60 evaluable patients, 16 patients achieved a partial response (27%; 95% confidence interval [CI], 16%-40%). The median progression-free survival period, overall survival period, and 1-year survival rate of the evaluable patients were 9.7 months (95% CI, 6.9-11.6 months), 16.2 months (95% CI, 13.5-21.3 months), and 72% (95%CI, 59%-82%), respectively. Of the 42 patients with a pretreatment serum CA19-9 level of {>=}100 U/ml, 34 (81%) patients showed a decrease of greater than 50%. Leukopenia (6 patients, 10%) and anorexia (4 patients, 7%) were the major grade 3-4 toxicities with chemoradiation therapy. Conclusions: The effect of S-1 with concurrent radiation therapy in patients with locally advanced PC was found to be very favorable, with only mild toxicity.« less

  18. Tumor Volume Estimation and Quasi-Continuous Administration for Most Effective Bevacizumab Therapy.

    PubMed

    Sápi, Johanna; Kovács, Levente; Drexler, Dániel András; Kocsis, Pál; Gajári, Dávid; Sápi, Zoltán

    2015-01-01

    Bevacizumab is an exogenous inhibitor which inhibits the biological activity of human VEGF. Several studies have investigated the effectiveness of bevacizumab therapy according to different cancer types but these days there is an intense debate on its utility. We have investigated different methods to find the best tumor volume estimation since it creates the possibility for precise and effective drug administration with a much lower dose than in the protocol. We have examined C38 mouse colon adenocarcinoma and HT-29 human colorectal adenocarcinoma. In both cases, three groups were compared in the experiments. The first group did not receive therapy, the second group received one 200 μg bevacizumab dose for a treatment period (protocol-based therapy), and the third group received 1.1 μg bevacizumab every day (quasi-continuous therapy). Tumor volume measurement was performed by digital caliper and small animal MRI. The mathematical relationship between MRI-measured tumor volume and mass was investigated to estimate accurate tumor volume using caliper-measured data. A two-dimensional mathematical model was applied for tumor volume evaluation, and tumor- and therapy-specific constants were calculated for the three different groups. The effectiveness of bevacizumab administration was examined by statistical analysis. In the case of C38 adenocarcinoma, protocol-based treatment did not result in significantly smaller tumor volume compared to the no treatment group; however, there was a significant difference between untreated mice and mice who received quasi-continuous therapy (p = 0.002). In the case of HT-29 adenocarcinoma, the daily treatment with one-twelfth total dose resulted in significantly smaller tumors than the protocol-based treatment (p = 0.038). When the tumor has a symmetrical, solid closed shape (typically without treatment), volume can be evaluated accurately from caliper-measured data with the applied two-dimensional mathematical model. Our results provide a theoretical background for a much more effective bevacizumab treatment using optimized administration.

  19. Results From the Imaging and Radiation Oncology Core Houston's Anthropomorphic Phantoms Used for Proton Therapy Clinical Trial Credentialing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, Paige A., E-mail: pataylor@mdanderson.org; Kry, Stephen F.; Alvarez, Paola

    Purpose: The purpose of this study was to summarize the findings of anthropomorphic proton phantom irradiations analyzed by the Imaging and Radiation Oncology Core Houston QA Center (IROC Houston). Methods and Materials: A total of 103 phantoms were irradiated by proton therapy centers participating in clinical trials. The anthropomorphic phantoms simulated heterogeneous anatomy of a head, liver, lung, prostate, and spine. Treatment plans included those for scattered, uniform scanning, and pencil beam scanning beam delivery modalities using 5 different treatment planning systems. For every phantom irradiation, point doses and planar doses were measured using thermoluminescent dosimeters (TLD) and film, respectively. Differencesmore » between measured and planned doses were studied as a function of phantom, beam delivery modality, motion, repeat attempt, treatment planning system, and date of irradiation. Results: The phantom pass rate (overall, 79%) was high for simple phantoms and lower for phantoms that introduced higher levels of difficulty, such as motion, multiple targets, or increased heterogeneity. All treatment planning systems overestimated dose to the target, compared to TLD measurements. Errors in range calculation resulted in several failed phantoms. There was no correlation between treatment planning system and pass rate. The pass rates for each individual phantom are not improving over time, but when individual institutions received feedback about failed phantom irradiations, pass rates did improve. Conclusions: The proton phantom pass rates are not as high as desired and emphasize potential deficiencies in proton therapy planning and/or delivery. There are many areas for improvement with the proton phantom irradiations, such as treatment planning system dose agreement, range calculations, accounting for motion, and irradiation of multiple targets.« less

  20. Assessment of hepatic function decline after stereotactic body radiation therapy for primary liver cancer.

    PubMed

    Toesca, Diego A S; Osmundson, Evan C; von Eyben, Rie; Shaffer, Jenny L; Koong, Albert C; Chang, Daniel T

    This study aims to determine how the albumin-bilirubin (ALBI) score compares with the Child-Pugh (CP) score for assessing liver function following stereotactic body radiation therapy (SBRT). In total, 60 patients, 40 with hepatocellular carcinoma (HCC) and 20 with cholangiocarcinoma (CCA), were treated with SBRT. Liver function panels were obtained before and at 1, 3, 6, and 12 months after SBRT. Laboratory values were censored after locoregional recurrence, further liver-directed therapies, or liver transplant. A significant decline in hepatic function occurred after SBRT for HCC patients only (P = .001 by ALBI score; P < .0001 by CP score). By converting radiation doses to biologically equivalent doses by using a standard linear quadratic model using α/β of 10, the strongest dosimetric predictor of liver function decline for HCC was the volume of normal liver irradiated by a dose of 40 Gy when assessing liver function by the ALBI score (P = .07), and the volume of normal liver irradiated by a dose of 20 Gy by using the CP score (P= .0009). For CCA patients, the volume of normal liver irradiated by a dose of 40 Gy remained the strongest dosimetric predictor when using the ALBI score (P = .002), but no dosimetric predictor was significant using the CP score. Hepatic function decline correlated with worse overall survival for HCC (by ALBI, P = .0005; by CP, P < .0001) and for CCA (by ALBI, P = NS; by CP, P = .008). ALBI score was similarly able to predict hepatic function decline compared with CP score, and both systems correlated with survival. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  1. Ocular side effects following intravitreal injection therapy for retinoblastoma: a systematic review.

    PubMed

    Smith, Stephen J; Smith, Brian D; Mohney, Brian G

    2014-03-01

    To describe the ocular side effects in patients receiving intravitreal injection therapy (IViT) for retinoblastoma. PubMed (1946-present), Scopus (all years), Science Citation Index (1900-present) and Conference Proceedings Citation Index-Science (1990-present) electronic databases were searched to identify all published reports of therapeutic intravitreal injections for retinoblastoma in humans. Ten studies with original IViT ocular side effect data were included in this systematic review. In these combined reports, a total of 1287 intravitreal injections were given to 306 eyes of 295 patients, with a mean follow-up of 74.1 months. Two hundred sixty-one (88.5%) patients received comparatively standard melphalan IViT doses (8-30 mcg). Ocular side effects occurred in 38 patients (17 significant, 21 minor). The proportion of patients experiencing potentially significant ocular side effects following standard melphalan IViT regimens was 0.031 (8/261; 95% CI 0.013 to 0.06). The side effects of these eight included iris atrophy in three, two each with chorioretinal atrophy and vitreous haemorrhage and one with retinal detachment. Of the other nine patients with significant complications, five experienced sight-threatening complications following dramatic dose escalations (four with melphalan, one with thiotepa), three experienced complications that are commonly associated with concurrent therapies given to these patients and one had a retinal detachment. Of the 61 patients receiving IViT via safety-enhancing injection techniques, all six significant side effects were either attributed to the therapeutic dose or confounded by concurrent treatments. Significant ocular complications following IViT for retinoblastoma are uncommon, and this risk may be reduced further by the use of careful injection technique and standard dosing regimens. Care must be taken in the dosing of intravitreal treatments to avoid potentially irreversible vision loss.

  2. A Phase 2 Trial of Oral Solithromycin 1200 mg or 1000 mg as Single-Dose Oral Therapy for Uncomplicated Gonorrhea.

    PubMed

    Hook, Edward W; Golden, Matthew; Jamieson, Brian D; Dixon, Paula B; Harbison, Hanne S; Lowens, Sylvan; Fernandes, Prabhavathi

    2015-10-01

    Progressive resistance to antimicrobial agents has reduced options for gonorrhea therapy worldwide. Solithromycin (CEM-101) is a novel oral fluoroketolide antimicrobial with substantial in vitro activity against Neisseria gonorrhoeae. We conducted a phase 2 trial of 2 oral doses of solithromycin (1200 and 1000 mg) for treatment of uncomplicated gonorrhea. A total of 59 participants were enrolled and treated in this trial; 28 participants received 1200 mg of solithromycin and 31 received 1000 mg. Forty-six (78%) participants had positive cultures for N. gonorrhoeae at the time of enrollment: 24 of the 28 persons (86%) who received 1200 mg of oral solithromycin, and 22 of 31 (71%) who received 1000 mg. In addition, 8 participants had positive pharyngeal gonococcal cultures, and 4 had positive rectal cultures. All patients with positive cultures for N. gonorrhoeae were cured at all sites of infection. Chlamydia trachomatis and Mycoplasma genitalium coinfections were evaluated using nucleic acid amplification tests and were negative at 1 week of follow-up in 9 of 11 (82%) participants positive for C. trachomatis and 7 of 10 (70%) participants positive for M. genitalium. Mild dose-related gastrointestinal side effects (nausea, loose stools, vomiting) were common but did not limit therapy. Oral single-dose solithromycin, in doses of 1000 mg and 1200 mg, was 100% effective for treatment of culture-proven gonorrhea at genital, oral, and rectal sites of infection and is a promising new agent for gonorrhea treatment. NCT01591447. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  3. CD206-Targeted Liposomal Myelin Basic Protein Peptides in Patients with Multiple Sclerosis Resistant to First-Line Disease-Modifying Therapies: A First-in-Human, Proof-of-Concept Dose-Escalation Study.

    PubMed

    Belogurov, Alexey; Zakharov, Konstantin; Lomakin, Yakov; Surkov, Kirill; Avtushenko, Sergey; Kruglyakov, Peter; Smirnov, Ivan; Makshakov, Gleb; Lockshin, Curtis; Gregoriadis, Gregory; Genkin, Dmitry; Gabibov, Alexander; Evdoshenko, Evgeniy

    2016-10-01

    Previously, we showed that CD206-targeted liposomal delivery of co-encapsulated immunodominant myelin basic protein (MBP) sequences MBP 46-62 , MBP 124-139 and MBP 147-170 (Xemys) suppressed experimental autoimmune encephalomyelitis in dark Agouti rats. The objective of this study was to assess the safety of Xemys in the treatment of patients with relapsing-remitting multiple sclerosis (MS) and secondary progressive MS, who failed to achieve a sustained response to first-line disease-modifying therapies. In this phase I, open-label, dose-escalating, proof-of-concept study, 20 patients with relapsing-remitting or secondary progressive MS received weekly subcutaneously injections with ascending doses of Xemys up to a total dose of 2.675 mg. Clinical examinations, including Expanded Disability Status Scale score, magnetic resonance imaging results, and serum cytokine concentrations, were assessed before the first injection and for up to 17 weeks after the final injection. Xemys was safe and well tolerated when administered for 6 weeks to a maximum single dose of 900 μg. Expanded Disability Status Scale scores and numbers of T2-weighted and new gadolinium-enhancing lesions on magnetic resonance imaging were statistically unchanged at study exit compared with baseline; nonetheless, the increase of number of active gadolinium-enhancing lesions on weeks 7 and 10 in comparison with baseline was statistically significant. During treatment, the serum concentrations of the cytokines monocyte chemoattractant protein-1, macrophage inflammatory protein-1β, and interleukin-7 decreased, whereas the level of tumor necrosis factor-α increased. These results provide evidence for the further development of Xemys as an antigen-specific, disease-modifying therapy for patients with MS.

  4. Mean Absorbed Dose to the Anal-Sphincter Region and Fecal Leakage among Irradiated Prostate Cancer Survivors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alsadius, David, E-mail: david.alsadius@oncology.gu.se; Hedelin, Maria; Division of Clinical Cancer Epidemiology, Department of Oncology-Pathology, Karolinska Institute, Stockholm

    2012-10-01

    Purpose: To supplement previous findings that the absorbed dose of ionizing radiation to the anal sphincter or lower rectum affects the occurrence of fecal leakage among irradiated prostate-cancer survivors. We also wanted to determine whether anatomically defining the anal-sphincter region as the organ at risk could increase the degree of evidence underlying clinical guidelines for restriction doses to eliminate this excess risk. Methods and Materials: We identified 985 men irradiated for prostate cancer between 1993 and 2006. In 2008, we assessed long-term gastrointestinal symptoms among these men using a study-specific questionnaire. We restrict the analysis to the 414 men whomore » had been treated with external beam radiation therapy only (no brachytherapy) to a total dose of 70 Gy in 2-Gy daily fractions to the prostate or postoperative prostatic region. On reconstructed original radiation therapy dose plans, we delineated the anal-sphincter region as an organ at risk. Results: We found that the prevalence of long-term fecal leakage at least once per month was strongly correlated with the mean dose to the anal-sphincter region. Examining different dose intervals, we found a large increase at 40 Gy; {>=}40 Gy compared with <40 Gy gave a prevalence ratio of 3.8 (95% confidence interval 1.6-8.6). Conclusions: This long-term study shows that mean absorbed dose to the anal-sphincter region is associated with the occurrence of long-term fecal leakage among irradiated prostate-cancer survivors; delineating the anal-sphincter region separately from the rectum and applying a restriction of a mean dose <40 Gy will, according to our data, reduce the risk considerably.« less

  5. SU-F-T-349: Dosimetric Comparison of Three Different Simultaneous Integrated Boost Irradiation Techniques for Multiple Brain Metastases: Intensity-Modulatedradiotherapy, Hybrid Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, X; Sun, T; Yin, Y

    Purpose: To study the dosimetric impact of intensity-modulated radiotherapy (IMRT), hybrid intensity-modulated radiotherapy (h-IMRT) and volumetric modulated arc therapy(VMAT) for whole-brain radiotherapy (WBRT) with simultaneous integrated boost in patients with multiple brain metastases. Methods: Ten patients with multiple brain metastases were included in this analysis. The prescribed dose was 45 Gy to the whole brain (PTVWBRT) and 55 Gy to individual brain metastases (PTVboost) delivered simultaneously in 25 fractions. Three treatment techniques were designed: the 7 equal spaced fields IMRT plan, hybrid IMRT plan and VMAT with two 358°arcs. In hybrid IMRT plan, two fields(90°and 270°) were planned to themore » whole brain. This was used as a base dose plan. Then 5 fields IMRT plan was optimized based on the two fields plan. The dose distribution in the target, the dose to the organs at risk and total MU in three techniques were compared. Results: For the target dose, conformity and homogeneity in PTV, no statistically differences were observed in the three techniques. For the maximum dose in bilateral lens and the mean dose in bilateral eyes, IMRT and h-IMRT plans showed the highest and lowest value respectively. No statistically significant differences were observed in the dose of optic nerve and brainstem. For the monitor units, IMRT and VMAT plans showed the highest and lowest value respectively. Conclusion: For WBRT with simultaneous integrated boost in patients with multiple brain metastases, hybrid IMRT could reduce the doses to lens and eyes. It is feasible for patients with brain metastases.« less

  6. Effect of mipomersen, an apolipoprotein B synthesis inhibitor, on low-density lipoprotein cholesterol in patients with familial hypercholesterolemia.

    PubMed

    Akdim, Fatima; Visser, Maartje E; Tribble, Diane L; Baker, Brenda F; Stroes, Erik S G; Yu, Rosie; Flaim, Joann D; Su, John; Stein, Evan A; Kastelein, John J P

    2010-05-15

    A randomized, double-blind, placebo-controlled, dose-escalation study was conducted to examine the efficacy and safety of mipomersen (ISIS 301012), an antisense inhibitor of apolipoprotein B, when added to conventional lipid-lowering therapy for patients with heterozygous familial hypercholesterolemia. A total of 44 patients were enrolled and were separated into 4 cohorts, with doses ranging from 50 to 300 mg (4:1 active treatment/placebo ratio). Patients received 8 doses subcutaneously during a 6-week treatment period. Patients assigned to the 300-mg dose continued for an additional 7 weeks with once-per-week dosing. The primary efficacy end point was the percentage of change from baseline to week 7 in low-density lipoprotein (LDL) cholesterol. Safety was assessed using the laboratory test results and according to the incidence, severity, and relation of adverse events to drug dose. Mipomersen produced significant reductions in LDL cholesterol and other atherogenic apolipoprotein B-containing lipoproteins. After 6 weeks of treatment, the LDL cholesterol level was reduced by 21% from baseline in the 200-mg/week dose group (p <0.05) and 34% from baseline in the 300-mg/week dose group (p <0.01), with a concomitant reduction in apolipoprotein B of 23% (p <0.05) and 33% (p <0.01), respectively. Injection site reactions were the most common adverse event. Elevations in liver transaminase levels (> or =3 times the upper limit of normal) occurred in 4 (11%) of 36 patients assigned to active treatment; 3 of these patients were in the highest dose group. In conclusion, mipomersen has an incremental LDL cholesterol lowering effect when added to conventional lipid-lowering therapy. Copyright 2010 Elsevier Inc. All rights reserved.

  7. SU-F-T-388: Comparison of Biophysical Indices in Hippocampal-Avoidance Whole Brain VMAT and IMRT Radiation Therapy Treatment Plans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kendall, E; Ahmad, S; Algan, O

    2016-06-15

    Purpose: To compare biophysical indices of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT) treatment plans for whole brain radiation therapy following the NRG-CC001 protocol. Methods: In this retrospective study, a total of fifteen patients were planned with Varian Eclipse Treatment Planning System using VMAT (RapidArc) and IMRT techniques. The planning target volume (PTV) was defined as the whole brain volume excluding a uniform three-dimensional 5mm expansion of the hippocampus volume. Prescribed doses in all plans were 30 Gy delivered over 10 fractions normalized to a minimum of 95% of the target volume receiving 100% of themore » prescribed dose. The NRG Oncology protocol guidelines were followed for contouring and dose-volume constraints. A single radiation oncologist evaluated all treatment plans. Calculations of statistical significance were performed using Student’s paired t-test. Results: All VMAT and IMRT plans met the NRG-CC001 protocol dose-volume criteria. The average equivalent uniform dose (EUD) for the PTV for VMAT vs. IMRT was respectively (19.05±0.33 Gy vs. 19.38±0.47 Gy) for α/β of 2 Gy and (19.47±0.30 Gy vs. 19.84±0.42 Gy) for α/β of 10 Gy. For the PTV, the average mean and maximum doses were 2% and 5% lower in VMAT plans than in IMRT plans, respectively. The average EUD and the normal tissue complication probability (NTCP) for the hippocampus in VMAT vs. IMRT plans were (15.28±1.35 Gy vs. 15.65±0.99 Gy, p=0.18) and (0.305±0.012 Gy vs. 0.308±0.008 Gy, p=0.192), respectively. The average EUD and NTCP for the optic chiasm were both 2% higher in VMAT than in IMRT plans. Conclusion: Though statistically insignificant, VMAT plans indicate a lower hippocampus EUD than IMRT plans. Also, a small variation in NTCP was found between plans.« less

  8. Pediatric Obesity: Pharmacokinetic Alterations and Effects on Antimicrobial Dosing.

    PubMed

    Natale, Stephanie; Bradley, John; Nguyen, William Huy; Tran, Tri; Ny, Pamela; La, Kirsten; Vivian, Eva; Le, Jennifer

    2017-03-01

    Limited data exist for appropriate drug dosing in obese children. This comprehensive review summarizes pharmacokinetic (PK) alterations that occur with age and obesity, and these effects on antimicrobial dosing. A thorough comparison of different measures of body weight and specific antimicrobial agents including cefazolin, cefepime, ceftazidime, daptomycin, doripenem, gentamicin, linezolid, meropenem, piperacillin-tazobactam, tobramycin, vancomycin, and voriconazole is presented. PubMed (1966-July 2015) and Cochrane Library searches were performed using these key terms: children, pharmacokinetic, obesity, overweight, body mass index, ideal body weight, lean body weight, body composition, and specific antimicrobial drugs. PK studies in obese children and, if necessary, data from adult studies were summarized. Knowledge of PK alterations stemming from physiologic changes that occur with age from the neonate to adolescent, as well as those that result from increased body fat, become an essential first step toward optimizing drug dosing in obese children. Excessive amounts of adipose tissue contribute significantly to body size, total body water content, and organ size and function that may modify drug distribution and clearance. PK studies that evaluated antimicrobial dosing primarily used total (or actual) body weight (TBW) for loading doses and TBW or adjusted body weight for maintenance doses, depending on the drugs' properties and dosing units. PK studies in obese children are imperative to elucidate drug distribution, clearance, and, consequently, the dose required for effective therapy in these children. Future studies should evaluate the effects of both age and obesity on drug dosing because the incidence of obesity is increasing in pediatric patients. © 2017 Pharmacotherapy Publications, Inc.

  9. SU-F-T-117: A Pilot Study of Organ Dose Reconstruction for Wilms Tumor Patients Treated with Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makkia, R; Pelletier, C; Jung, J

    Purpose: To reconstruct major organ doses for the Wilms tumor pediatric patients treated with radiation therapy using pediatric computational phantoms, treatment planning system (TPS), and Monte Carlo (MC) dose calculation methods. Methods: A total of ten female and male pediatric patients (15–88 months old) were selected from the National Wilms Tumor Study cohort and ten pediatric computational phantoms corresponding to the patient’s height and weight were selected for the organ dose reconstruction. Treatment plans were reconstructed on the computational phantoms in a Pinnacle TPS (v9.10) referring to treatment records and exported into DICOM-RT files, which were then used to generatemore » the input files for XVMC MC code. The mean doses to major organs and the dose received by 50% of the heart were calculated and compared between TPS and MC calculations. The same calculations were conducted by replacing the computational human phantoms with a series of diagnostic patient CT images selected by matching the height and weight of the patients to validate the anatomical accuracy of the computational phantoms. Results: Dose to organs located within the treatment fields from the computational phantoms and the diagnostic patient CT images agreed within 2% for all cases for both TPS and MC calculations. The maximum difference of organ doses was 55.9 % (thyroid), but the absolute dose difference in this case was 0.33 Gy which was 0.96% of the prescription dose. The doses to ovaries and testes from MC in out-of-field provided more discrepancy (the maximum difference of 13.2% and 50.8%, respectively). The maximum difference of the 50% heart volume dose between the phantoms and the patient CT images was 40.0%. Conclusion: This study showed the pediatric computational phantoms are applicable to organ doses reconstruction for the radiotherapy patients whose three-dimensional radiological images are not available.« less

  10. Survival After Shock Requiring High-Dose Vasopressor Therapy

    PubMed Central

    Lanspa, Michael J.; Jones, Jason P.; Kuttler, Kathryn G.; Li, Yao; Carlson, Rick; Miller, Russell R.; Hirshberg, Eliotte L.; Grissom, Colin K.; Morris, Alan H.

    2013-01-01

    Background: Some patients with hypotensive shock do not respond to usual doses of vasopressor therapy. Very little is known about outcomes after high-dose vasopressor therapy (HDV). We sought to characterize survival among patients with shock requiring HDV. We also evaluated the possible utility of stress-dose corticosteroid therapy in these patients. Methods: We conducted a retrospective study of patients with shock requiring HDV in the ICUs of five hospitals from 2005 through 2010. We defined HDV as receipt at any point of ≥ 1 μg/kg/min of norepinephrine equivalent (calculated by summing norepinephrine-equivalent infusion rates of all vasopressors). We report survival 90 days after hospital admission. We evaluated receipt of stress-dose corticosteroids, cause of shock, receipt of CPR, and withdrawal or withholding of life support therapy. Results: We identified 443 patients meeting inclusion criteria. Seventy-six (17%) survived. Survival was similar (20%) among the 241 patients with septic shock. Among the 367 nonsurvivors, 254 (69%) experienced withholding/withdrawal of care, and 115 (31%) underwent CPR. Stress-dose corticosteroid therapy was associated with increased survival (P = .01). Conclusions: One in six patients with shock survived to 90 days after HDV. The majority of nonsurvivors died after withdrawal or withholding of life support therapy. A minority of patients underwent CPR. Additionally, stress-dose corticosteroid therapy appears reasonable in patients with shock requiring HDV. PMID:22911566

  11. Tolerance doses of cutaneous and mucosal tissues in ring-necked parakeets (Psittacula krameri) for external beam megavoltage radiation.

    PubMed

    Barron, Heather W; Roberts, Royce E; Latimer, Kenneth S; Hernandez-Divers, Stephen; Northrup, Nicole C

    2009-03-01

    Currently used dosages for external-beam megavoltage radiation therapy in birds have been extrapolated from mammalian patients and often appear to provide inadequate doses of radiation for effective tumor control. To determine the tolerance doses of cutaneous and mucosal tissues of normal birds in order to provide more effective radiation treatment for tumors that have been shown to be radiation responsive in other species, ingluvial mucosa and the skin over the ingluvies of 9 ring-necked parakeets (Psittacula krameri) were irradiated in 4-Gy fractions to a total dose of either 48, 60, or 72 Gy using an isocentric cobalt-60 teletherapy unit. Minimal radiation-induced epidermal changes were present in the high-dose group histologically. Neither dose-related acute nor chronic radiation effects could be detected in any group grossly in cutaneous or mucosal tissue over a 9-month period. Radiation doses of 72 Gy in 4-Gy fractions were well tolerated in the small number of ring-necked parakeets in this initial tolerance dose study.

  12. Application of biological effective dose (BED) to estimate the duration of symptomatic relief and repopulation dose equivalent in palliative radiotherapy and chemotherapy.

    PubMed

    Jones, Bleddyn; Cominos, Matilda; Dale, Roger G

    2003-03-01

    To investigate the potential for mathematic modeling in the assessment of symptom relief in palliative radiotherapy and cytotoxic chemotherapy. The linear quadratic model of radiation effect with the overall treatment time and the daily dose equivalent of repopulation is modified to include the regrowth time after completion of therapy. The predicted times to restore the original tumor volumes after treatment are dependent on the biological effective dose (BED) delivered and the repopulation parameter (K); it is also possible to estimate K values from analysis of palliative treatment response durations. Hypofractionated radiotherapy given at a low total dose may produce long symptom relief in slow-growing tumors because of their low alpha/beta ratios (which confer high fraction sensitivity) and their slow regrowth rates. Cancers that have high alpha/beta ratios (which confer low fraction sensitivity), and that are expected to repopulate rapidly during therapy, are predicted to have short durations of symptom control. The BED concept can be used to estimate the equivalent dose of radiotherapy that will achieve the same duration of symptom relief as palliative chemotherapy. Relatively simple radiobiologic modeling can be used to guide decision-making regarding the choice of the most appropriate palliative schedules and has important implications in the design of radiotherapy or chemotherapy clinical trials. The methods described provide a rationalization for treatment selection in a wide variety of tumors.

  13. Investigation of the effect of traditional Chinese medicine on pain and inflammation in chronic nonbacterial prostatitis in rats.

    PubMed

    Liu, Y-J; Song, G-H; Liu, G T

    2016-08-01

    According to traditional Chinese medicine, the symptoms of chronic nonbacterial prostatitis/chronic pelvic pain syndrome (CNP/CPPS) may be treated using a cocktail of herbs that stimulate blood circulation ('activating blood circulation formula'). We investigated the effect of three doses of this formula on a rat model of CNP/CPPS. Male Wistar rats were injected with a saline extract of male sex accessory glands on days 0 and 30 to induce prostatitis and then treated daily by gavage between days 32 and 60. Treatment with low, medium and high doses of activating blood circulation formula resulted in an almost total rescue of paw withdrawal threshold at day 60, and treatment with the highest dose also significantly decreased prostate inflammation (assessed histopathologically). We further observed elevated serum prostaglandin E2 levels in the CNP/CPPS model which decreased upon high-dose treatment, and increased Cox-2 expression in the prostate and spinal cord dorsal horn which was rescued in both tissues in the high-dose group and in the prostate in the medium-dose group. These results shed light on a possible mechanism by which activating blood circulation therapy may alleviate pain in a rat model of CNP/CPPS by downregulating Cox-2 expression in the spinal cord, thereby raising the pain threshold. Further research will be needed to fully characterise the mechanism by which activating blood circulation therapy produces this therapeutic effect. © 2016 Blackwell Verlag GmbH.

  14. SU-E-T-187: Feasibility Study of Stereotactic Liver Radiation Therapy Using Multiple Divided Partial Arcs in Volumetric Modulated Arc Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Y; Ozawa, S; Tsegmed, U

    2014-06-01

    Purpose: To verify volumetric modulated arc therapy (VMAT) using flattening filter free (FFF) mode with jaw tracking (JT) feature for single breath hold as long as 15 s per arc in liver stereotactic body radiation therapy (SBRT) against intensity modulated radiation therapy (IMRT) FFF-JT. Methods: Ten hepatocellular carcinoma (HCC) cases were planned with 10 MV FFF using Pinnacle3 treatment planning system which delivered by TrueBeam to administer 48 Gy/ 4 fractions. Eight non-coplanar beams were assigned to IMRT using step-and-shoot technique. For VMAT, two or three non-coplanar partial arcs (up to 180 degrees) were further divided into subarcs with gantrymore » rotation less than 80 degrees to limit delivery time within 15 s. Dose distributions were verified using OCTAVIUS II system and pass rates were evaluated using gamma analysis with criteria of 3%/3 mm at threshold of 5% to the maximum dose. The actual irradiation time was measured. Results: The VMAT-FFF-JT of partial-arcs with sub-divided arcs was able to produce a highly conformal plan as well as IMRT-FFF-JT. Isodose lines and DVH showed slight improvement in dosimetry when JT was employed for both IMRT and VMAT. Consequently, VMAT-FFF-JT was superior in reducing the dose to liver minus gross tumor volume. VMAT-FFF-JT has shorter total treatment time compared with 3D conformal radiation therapy (3D-CRT) FFF because the gantry was rotated simultaneously with the beam delivery in VMAT. Moreover, due to the small and regular shape of HCC, VMAT-FFF-JT offered less multileaf collimator motion, thus the interplay effect is expected to be reduced. The patient specific QA of IMRT and VMAT acquired the pass rates higher than 90%. Conclusion: VMAT-FFF-JT could be a promising technique for liver SBRT as the sub-divided arcs method was able to accommodate a single breath hold irradiation time of less than 15 s without deterioration of the dose distribution compared with IMRT-FFF-JT.« less

  15. Proton or photon irradiation for hemangiomas of the choroid? A retrospective comparison

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoecht, Stefan; Wachtlin, Joachim; Bechrakis, Nikolaos E.

    2006-10-01

    Purpose: The aim of this study was to compare, on a retrospective basis, the results of therapy in patients with uveal hemangioma treated with photon or proton irradiation at a single center. Methods and Materials: From 1993 to 2002 a total of 44 patients were treated. Until 1998 radiotherapy was given with 6 MV photons in standard fractionation of 2.0 Gy 5 times per week. In 1998 proton therapy became available and was used since then. A dose of 20 to 22.5 Cobalt Gray Equivalent (CGE) 68 MeV protons was given on 4 consecutive days. Progressive symptoms or deterioration ofmore » vision were the indications for therapy. Results: Of the 44 patients treated, 36 had circumscribed choroidal hemangiomas and 8 had diffuse choroidal hemangiomas (DCH) and Sturge-Weber syndrome. Of the patients, 19 were treated with photons with a total dose in the range of 16 to 30 Gy. A total of 25 patients were irradiated with protons. All patients with DCH but 1 were treated with photons. Stabilization of visual acuity was achieved in 93.2% of all patients. Tumor thickness decreased in 95.4% and retinal detachment resolved in 92.9%. Late effects, although generally mild or moderate, were frequently detected. In all, 40.9% showed radiation-induced optic neuropathy, maximum Grade I. Retinopathy was found in 29.5% of cases, but only 1 patient experienced more than Grade II severity. Retinopathy and radiation-induced optic neuropathy were reversible in some of the patients and in some resolved completely. No differences could be detected between patients with circumscribed choroidal hemangiomas treated with protons and photons. Treatment was less effective in DCH patients (75%). Conclusions: Radiotherapy is effective in treating choroidal hemangiomas with respect to visual acuity and tumor thickness but a benefit of proton therapy could not be detected. Side effects are moderate but careful monitoring for side effects should be part of the follow-up procedures.« less

  16. Optimization of dual-energy CT acquisitions for proton therapy using projection-based decomposition.

    PubMed

    Vilches-Freixas, Gloria; Létang, Jean Michel; Ducros, Nicolas; Rit, Simon

    2017-09-01

    Dual-energy computed tomography (DECT) has been presented as a valid alternative to single-energy CT to reduce the uncertainty of the conversion of patient CT numbers to proton stopping power ratio (SPR) of tissues relative to water. The aim of this work was to optimize DECT acquisition protocols from simulations of X-ray images for the treatment planning of proton therapy using a projection-based dual-energy decomposition algorithm. We have investigated the effect of various voltages and tin filtration combinations on the SPR map accuracy and precision, and the influence of the dose allocation between the low-energy (LE) and the high-energy (HE) acquisitions. For all spectra combinations, virtual CT projections of the Gammex phantom were simulated with a realistic energy-integrating detector response model. Two situations were simulated: an ideal case without noise (infinite dose) and a realistic situation with Poisson noise corresponding to a 20 mGy total central dose. To determine the optimal dose balance, the proportion of LE-dose with respect to the total dose was varied from 10% to 90% while keeping the central dose constant, for four dual-energy spectra. SPR images were derived using a two-step projection-based decomposition approach. The ranges of 70 MeV, 90 MeV, and 100 MeV proton beams onto the adult female (AF) reference computational phantom of the ICRP were analytically determined from the reconstructed SPR maps. The energy separation between the incident spectra had a strong impact on the SPR precision. Maximizing the incident energy gap reduced image noise. However, the energy gap was not a good metric to evaluate the accuracy of the SPR. In terms of SPR accuracy, a large variability of the optimal spectra was observed when studying each phantom material separately. The SPR accuracy was almost flat in the 30-70% LE-dose range, while the precision showed a minimum slightly shifted in favor of lower LE-dose. Photon noise in the SPR images (20 mGy dose) had lower impact on the proton range accuracy as comparable results were obtained for the noiseless situation (infinite dose). Root-mean-square range errors averaged over all irradiation angles associated to dual-energy imaging were comprised between 0.50 mm and 0.72 mm for the noiseless situation and between 0.51 mm and 0.77 mm for the realistic scenario. The impact of the dual-energy spectra and the dose allocation between energy levels on the SPR accuracy and precision determined through a projection-based dual-energy algorithm were evaluated to guide the choice of spectra for dual-energy CT for proton therapy. The dose balance between energy levels was not found to be sensitive for the SPR estimation. The optimal pair of dual-energy spectra was material dependent but on a heterogeneous anthropomorphic phantom, there was no significant difference in range accuracy and the choice of spectra could be driven by the precision, i.e., the energy gap. © 2017 American Association of Physicists in Medicine.

  17. Lung Size and the Risk of Radiation Pneumonitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Briere, Tina Marie, E-mail: tmbriere@mdanderson.org; Krafft, Shane; Liao, Zhongxing

    2016-02-01

    Purpose: The purpose of this study was to identify patient populations treated for non-small cell lung cancer (NSCLC) who may be more at risk of radiation pneumonitis. Methods and Materials: A total of 579 patients receiving fractionated 3D conformal or intensity modulated radiation therapy (IMRT) for NSCLC were included in the study. Statistical analysis was performed to search for cohorts of patients with higher incidences of radiation pneumonitis. In addition to conventional risk factors, total and spared lung volumes were analyzed. The Lyman-Kutcher-Burman (LKB) and cure models were then used to fit the incidence of radiation pneumonitis as a functionmore » of lung dose and other factors. Results: Total lung volumes with a sparing of less than 1854 cc at 40 Gy were associated with a significantly higher incidence of radiation pneumonitis at 6 months (38% vs 12% for patients with larger volumes, P<.001). This patient cohort was overwhelmingly female and represented 22% of the total female population of patients and nearly 30% of the cases of radiation pneumonitis. An LKB fit to normal tissue complication probability (NTCP) including volume as a dose modifying factor resulted in a dose that results in a 50% probability of complication for the smaller spared volume cohort that was 9 Gy lower than the fit to all mean lung dose data and improved the ability to predict radiation pneumonitis (P<.001). Using an effective dose parameter of n=0.42 instead of mean lung dose further improved the LKB fit. Fits to the data using the cure model produced similar results. Conclusions: Spared lung volume should be considered when treating NSCLC patients. Separate dose constraints based on smaller spared lung volume should be considered. Smaller spared lung volume patients should be followed closely for signs of radiation pneumonitis.« less

  18. Glyburide transport across the human placenta.

    PubMed

    Schwartz, Rachelle A; Rosenn, Barak; Aleksa, Katarina; Koren, Gideon

    2015-03-01

    To estimate the magnitude of transplacental transfer of glyburide in women with gestational diabetes mellitus (GDM). A prospective, observational study was conducted on women with GDM on glyburide therapy. On delivery admission, the glyburide dose and time of last dose were recorded. Immediately postdelivery, maternal and umbilical venous blood samples were obtained and the concentrations of glyburide were determined by high-performance liquid chromatography-mass spectrometry with a limit of detection of 0.25 ng/mL. Nineteen patient dyads were analyzed. The mean total daily maternal glyburide dose was 6.6±6.3 mg per day and the mean time between last dose and sampling was 13.3±6.5 hours. The mean maternal serum glyburide level at birth was 15.4±20.8 ng/mL, whereas the mean umbilical glyburide level was 7.5±8.2 ng/mL, which showed a statistical correlation (r=0.72, P<.01). There were statistically significant relationships between total maternal glyburide dose (1.25-20 mg per day) and maternal glyburide levels (0.93-70.71 ng/mL; r=0.46, P≤.01) and between total maternal glyburide dose and umbilical glyburide levels (0.95-32.41 ng/mL; r=0.43, P≤.01) However, we observed wide variability in maternal and umbilical glyburide levels at both extremes of the total glyburide dose. Seventy-nine percent of cord samples (15/19) had glyburide levels less than 10 ng/mL (the limit of detection reported in earlier studies) and 37% (7/19) were higher than the corresponding maternal samples. Transplacental transfer of glyburide is highly variable among patients, corroborating ex vivo placental perfusion studies showing a transport-mediated glyburide efflux from the fetal to the maternal circulation. In most neonates (79%), glyburide levels were below 10 ng/mL. III.

  19. Comparison of two dosing schedules for subcutaneous injections of low-dose anti-CD20 veltuzumab in relapsed immune thrombocytopenia

    PubMed Central

    Liebman, Howard A.; Saleh, Mansoor N.; Bussel, James B.; Negrea, O. George; Horne, Heather; Wegener, William A.; Goldenberg, David M.

    2016-01-01

    We compared two dosing schedules for subcutaneous injections of a low-dose humanized anti-CD20 antibody, veltuzumab, in immune thrombocytopenia. Fifty adults with primary immune thrombocytopenia, in whom one or more lines of standard therapy had failed and who had a platelet count <30×109/L but no major bleeding, initially received escalating 80, 160, or 320 mg doses of subcutaneous veltuzumab administered twice, 2 weeks apart; the last group received once-weekly doses of 320 mg for 4 weeks. In all dose groups, injection reactions were transient and mild to moderate; there were no other safety issues. Forty-seven response-evaluable patients had 23 (49%) objective responses (platelet counts ≥30×109/L and ≥2 × baseline) including 15 (32%) complete responses (platelets ≥100×109/L). Responses (including complete responses) and bleeding reduction occurred in all dose groups and were not dose-dependent. In contrast, response duration increased progressively with total dose, reaching a median of 2.7 years with the four once-weekly 320-mg doses. Among nine responders retreated at relapse, three at higher dose levels responded again, including one patient who was retreated four times. In all dose groups, B-cell depletion occurred after the first dose until recovery starting 12 to 16 weeks after treatment. Veltuzumab serum levels increased with dose group according to total dose administered, but terminal half-life and clearance were comparable. Human anti-veltuzumab antibody titers developed without apparent dose dependence in nine patients, of whom six responded including five who had complete responses. Subcutaneous veltuzumab was convenient, well-tolerated, and active, without causing significant safety concerns. Platelet responses and bleeding reduction occurred in all dose groups, and response durability appeared to improve with higher doses. Clinicaltrials.gov identifier: NCT00547066 PMID:27515248

  20. The impact of extended release exenatide as adjuvant therapy on hemoglobin A1C, weight, and total daily dose of insulin in patients with type 2 diabetes mellitus using U-500 insulin.

    PubMed

    Farwig, Phillip A; Zielinski, Angela J; Accursi, Mallory L; Burant, Christopher J

    2017-12-01

    To evaluate the efficacy and safety of adjuvant exenatide extended release (ER) therapy in patients treated with regular U-500 insulin. In this retrospective chart review at an ambulatory care center in the Midwest, 18 patients with type 2 diabetes being treated with regular U-500 insulin and adjuvant exenatide ER were identified. These patients were evaluated for outcomes following the addition of exenatide ER. The primary outcome was change in HbA 1C from baseline to 3, 6, and 12months. Secondary outcomes included change in weight, total daily dose (TDD) of insulin, and hypoglycemia. Repeated measures ANOVA was performed to assess the differences in mean scores over four time periods. A total of 18 of 50 patients met inclusion criteria with sufficient data to be included in analysis. HbA 1C showed non-significant findings from baseline to 12months (8.08% vs. 8.23%; p=0.75). A non-significant, modest weight loss occurred (146.4kgvs. 144.2kg; -2.2kg; p=0.31). A significant decrease in TDD of insulin was observed (378 units vs. 326 units; p<0.001). There was a trend towards hypoglycemia from baseline to month 3 post addition of exenatide ER (0.33 events vs. 1.33 events; p=0.055). In patients treated with regular U-500 insulin, adjuvant exenatide ER therapy showed no significant improvement in HbA 1C , but did show modest weight loss as well as decreased insulin requirements to achieve a HbA 1C that was comparable to baseline. Published by Elsevier B.V.

  1. A systematic review of publications on charged particle therapy for hepatocellular carcinoma.

    PubMed

    Igaki, Hiroshi; Mizumoto, Masashi; Okumura, Toshiyuki; Hasegawa, Kiyoshi; Kokudo, Norihiro; Sakurai, Hideyuki

    2018-06-01

    Charged particle therapy (proton beam therapy and carbon ion therapy) is a form of radiotherapy which has the unique characteristic of superior depth dose distribution, and has been used for the treatment of hepatocellular carcinoma (HCC) in a limited number of patients, especially in Japan. We undertook a systematic review to define the clinical utility of charged particle therapy for patients with HCC. We searched the MEDLINE database from 1983 to June 2016 to identify clinical studies on charged particle therapy for HCC. Primary outcomes of interest were local control, overall survival, and late radiation morbidities. A total of 13 cohorts from 11 papers were selected from an initial dataset of 78 papers. They included a randomized controlled trial comparing proton beam therapy with transarterial chemoembolization, 9 phase I or II trials and 2 retrospective studies. The reported actuarial local control rates ranged from 71.4-95% at 3 years, and the overall survival rates ranged from 25-42.3% at 5 years. Late severe radiation morbidities were uncommon, and a total of 18 patients with grade ≥3 late adverse events were reported among the 787 patients included in this analysis. Charged particle therapy for HCC was associated with good local control with limited probability of severe morbidities. The cost-effectiveness and the distinctive clinical advantages of charged particle therapies should be clarified in order to become a socially accepted treatment modality for HCC.

  2. Positioning accuracy and daily dose assessment for prostate cancer treatment using in-room CT image guidance at a proton therapy facility.

    PubMed

    Maeda, Yoshikazu; Sato, Yoshitaka; Minami, Hiroki; Yasukawa, Yutaka; Yamamoto, Kazutaka; Tamamura, Hiroyasu; Shibata, Satoshi; Bou, Sayuri; Sasaki, Makoto; Tameshige, Yuji; Kume, Kyo; Ooto, Hiroshi; Kasahara, Shigeru; Shimizu, Yasuhiro; Saga, Yusuke; Omoya, Akira; Saitou, Makoto

    2018-05-01

    To evaluate the effectiveness of CT image-guided proton radiotherapy for prostate cancer by analyzing the positioning uncertainty and assessing daily dose change due to anatomical variations. Patients with prostate cancer were treated by opposed lateral proton beams based on a passive scattering method using an in-room CT image-guided system. The system employs a single couch for both CT scanning and beam delivery. The patient was positioned by matching the boundary between the prostate and the rectum's anterior region identified in the CT images to the corresponding boundary in the simulator images after bone matching. We acquired orthogonal kV x-ray images after couch movement and confirmed the body position by referring to the bony structure prior to treatment. In offline analyses, we contoured the targeted anatomical structures on 375 sets of daily in-room CT images for 10 patients. The uncertainty of the image-matching procedure was evaluated using the prostate contours and actual couch corrections. We also performed dose calculations using the same set of CT images, and evaluated daily change of dose-volume histograms (DVHs) to compare the effectiveness of the treatment using prostate matching to the bone-matching procedure. The isocenter shifts by prostate matching after bone matching were 0.5 ± 1.8 and -0.8 ± 2.6 mm along the superior-inferior (SI) and anterior-posterior (AP) directions, respectively. The body movement errors (σ) after couch movement were 0.7, 0.5, and 0.3 mm along the lateral, SI and AP direction, respectively, for 30 patients. The estimated errors (σ) in the prostate matching were 1.0 and 1.3 mm, and, in conjunction with the movement errors, the total positioning uncertainty was estimated to be 1.0 and 1.4 mm along the SI and AP directions, respectively. Daily DVH analyses showed that in the prostate matching, 98.7% and 86.1% of the total 375 irradiations maintained a dose condition of V 95%  > 95% for the prostate and a dose constraint of V 77%  < 18% for the rectum, whereas 90.4% and 66.1% of the total irradiations did so when bone matching was used. The dose constraint of the rectum and dose coverage of the prostate were better maintained by prostate matching than bone matching (P < 0.001). The daily variation in the dose to the seminal vesicles (SVs) was large, and only 40% of the total irradiations maintained the initial planned values of V 95% for high-risk treatment. Nevertheless, the deviations from the original value were -4 ± 7% and -5 ± 11% in the prostate and bone matching, respectively, and a better dose coverage of the SV was achieved by the prostate matching. The correction of repositioning along the AP and SI direction from conventional bone matching in CT image-guided proton therapy was found to be effective to maintain the dose constraint of the rectum and the dose coverage of the prostate. This work indicated that prostate cancer treatment by prostate matching using CT image guidance may be effective to reduce the rectal complications and achieve better tumor control of the prostate. However, an adaptive approach is desirable to maintain better dose coverage of the SVs. © 2018 American Association of Physicists in Medicine.

  3. Analysis of peripheral doses for base of tongue treatment by linear accelerator and helical TomoTherapy IMRT

    PubMed Central

    Lamba, Michael A. S.; Elson, Howard R.

    2010-01-01

    The purpose of this study was to compare the peripheral doses to various organs from a typical head and neck intensity‐modulated radiation therapy (IMRT) treatment delivered by linear accelerator (linac) and helical TomoTherapy. Multiple human CT data sets were used to segment critical structures and organs at risk, fused and adjusted to an anthropomorphic phantom. Eighteen contours were designated for thermoluminescent dosimeter (TLD) placement. Following the RTOG IMRT Protocol 0522, treatment of the primary tumor and involved nodes (PTV70) and subclinical disease sites (PTV56) was planned utilizing IMRT to 70 Gy and 56 Gy. Clinically acceptable treatment plans were produced for linac and TomoTherapy treatments. TLDs were placed and each treatment plan was delivered to the anthropomorphic phantom four times. Within 2.5 cm (one helical TomoTherapy field width) superior and inferior to the field edges, normal tissue doses were on average 45% lower using linear accelerator. Beyond 2.5 cm, the helical TomoTherapy normal tissue dose was an average of 52% lower. The majority of points proved to be statistically different using the Student's t‐test with p<0.05. Using one method of calculation, probability of a secondary malignancy was 5.88% for the linear accelerator and 4.08% for helical TomoTherapy. Helical TomoTherapy delivers more dose than a linac immediately above and below the treatment field, contributing to the higher peripheral doses adjacent to the field. At distances beyond one field width (where leakage is dominant), helical TomoTherapy doses are lower than linear accelerator doses. PACS number: 87.50.cm Dosimetry/exposure assessment

  4. High-Dose Methylprednisolone for Veno-Occlusive Disease of the Liver in Pediatric Hematopoietic Stem Cell Transplantation Recipients

    PubMed Central

    Myers, Kasiani C.; Lawrence, Julia; Marsh, Rebecca A.; Davies, Stella M.; Jodele, Sonata

    2017-01-01

    Veno-occlusive disease (VOD) of the liver is a well-recognized serious complication of hematopoietic stem cell transplantation (HSCT), with few successful treatment modalities available for severe disease. Some reports have demonstrated success in adults with the use of high-dose steroid therapy, but experience in the pediatric population is lacking. We retrospectively reviewed HSCT patients treated at our institution since 2003 and identified 15 (2.4%) who developed VOD. Of these, nine (60%) were treated with intravenous high-dose methylprednisolone (500 mg/m2 per dose every 12 hours for six doses). Steroid therapy was initiated at or before first ultrasound evidence of reversal of portal venous flow and before meeting criteria for initiation of defibrotide therapy. Four patients were also treated with defibrotide starting 2 to 5 days after initiation of steroids. Eight of nine patients (88%) with VOD were diagnosed with multiorgan failure. Response to high-dose steroid therapy as defined by decrease in bilirubin by 50% in 10 days from therapy initiation was noted in six of nine patients (67%), occurring within 3 to 6 days of steroid therapy. Two patients died from multiorgan failure due to VOD. Seven survivors of VOD recovered at the median 6 days (range, 5 to 38) from VOD diagnosis. Overall, VOD survival as a group was 78%; however, survival among responders was 100%. No serious toxicities related to high-dose steroid therapy were observed. We conclude that high-dose steroid therapy if initiated early may reverse VOD of the liver in pediatric HSCT patients, abrogating the need for defibrotide therapy with its associated toxicities and regulatory difficulties. PMID:23211838

  5. Radiation Dose-rate Reduction Pattern in Well-differentiated Thyroid Cancer Treated with I-131.

    PubMed

    Khan, Shahbaz Ahmad; Khan, Muhammad Saqib; Arif, Muhammad; Durr-e-Sabih; Rahim, Muhammad Kashif; Ahmad, Israr

    2015-07-01

    To determine the patterns of dose rate reduction in single and multiple radioiodine (I-131) therapies in cases of well differentiated thyroid cancer patients. Analytical series. Department of Nuclear Medicine and Radiation Physics, Multan Institute of Nuclear Medicine and Radiotherapy (MINAR), Multan, Pakistan, from December 2006 to December 2013. Ninety three patients (167 therapies) with well differentiated thyroid cancer treated with different doses of I-131 as an in-patient were inducted. Fifty four patients were given only single I-131 therapy dose ranging from 70 mCi (2590 MBq) to 150 mCi (5550 MBq). Thirty nine patients were treated with multiple I-131 radioisotope therapy doses ranging from 80 mCi (2960 MBq) to 250 mCi (9250 MBq). T-test was applied on the sample data showed statistically significant difference between the two groups with p-value (p < 0.01) less than 0.05 taken as significant. There were 68 females and 25 males with an age range of 15 to 80 years. Mean age of the patients were 36 years. Among the 93 cases of first time Radio Active Iodine (RAI) therapy, 59 cases (63%) were discharged after 48 hours. Among 39 patients who received RAI therapy second time or more, most were discharged earlier after achieving acceptable discharge dose rate i.e 25 µSv/hour; 2 out of 39 (5%) were discharged after 48 hours. In 58% patients, given single I-131 therapy dose, majority of these were discharged after 48 hours without any major complications. For well differentiated thyroid cancer patients, rapid dose rate reduction is seen in patients receiving second or subsequent radioiodine (RAI) therapy, as compared to first time receiving RAI therapy.

  6. Calculated organ doses using Monte Carlo simulations in a reference male phantom undergoing HDR brachytherapy applied to localized prostate carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Candela-Juan, Cristian; Perez-Calatayud, Jose; Ballester, Facundo

    Purpose: The aim of this study was to obtain equivalent doses in radiosensitive organs (aside from the bladder and rectum) when applying high-dose-rate (HDR) brachytherapy to a localized prostate carcinoma using {sup 60}Co or {sup 192}Ir sources. These data are compared with results in a water phantom and with expected values in an infinite water medium. A comparison with reported values from proton therapy and intensity-modulated radiation therapy (IMRT) is also provided. Methods: Monte Carlo simulations in Geant4 were performed using a voxelized phantom described in International Commission on Radiological Protection (ICRP) Publication 110, which reproduces masses and shapes frommore » an adult reference man defined in ICRP Publication 89. Point sources of {sup 60}Co or {sup 192}Ir with photon energy spectra corresponding to those exiting their capsules were placed in the center of the prostate, and equivalent doses per clinical absorbed dose in this target organ were obtained in several radiosensitive organs. Values were corrected to account for clinical circumstances with the source located at various positions with differing dwell times throughout the prostate. This was repeated for a homogeneous water phantom. Results: For the nearest organs considered (bladder, rectum, testes, small intestine, and colon), equivalent doses given by {sup 60}Co source were smaller (8%-19%) than from {sup 192}Ir. However, as the distance increases, the more penetrating gamma rays produced by {sup 60}Co deliver higher organ equivalent doses. The overall result is that effective dose per clinical absorbed dose from a {sup 60}Co source (11.1 mSv/Gy) is lower than from a {sup 192}Ir source (13.2 mSv/Gy). On the other hand, equivalent doses were the same in the tissue and the homogeneous water phantom for those soft tissues closer to the prostate than about 30 cm. As the distance increased, the differences of photoelectric effect in water and soft tissue, and appearance of other materials such as air, bone, or lungs, produced variations between both phantoms which were at most 35% in the considered organ equivalent doses. Finally, effective doses per clinical absorbed dose from IMRT and proton therapy were comparable to those from both brachytherapy sources, with brachytherapy being advantageous over external beam radiation therapy for the furthest organs. Conclusions: A database of organ equivalent doses when applying HDR brachytherapy to the prostate with either {sup 60}Co or {sup 192}Ir is provided. According to physical considerations, {sup 192}Ir is dosimetrically advantageous over {sup 60}Co sources at large distances, but not in the closest organs. Damage to distant healthy organs per clinical absorbed dose is lower with brachytherapy than with IMRT or protons, although the overall effective dose per Gy given to the prostate seems very similar. Given that there are several possible fractionation schemes, which result in different total amounts of therapeutic absorbed dose, advantage of a radiation treatment (according to equivalent dose to healthy organs) is treatment and facility dependent.« less

  7. EXCRETION OF P$sup 32$ AFTER THERAPY FOR POLYCYTHEMIA RUBRA VERA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weijer, D.L.; Duggan, H.E.; Scott, D.B.

    1962-09-01

    Fifteen subjects undergoing treatment for polycythemia rubra vera were given P/sup 32/. Carrier-free P/sup 32/ was administered intravenously in 11 and orally in 6. Total excretion studies were carried out in each case for periods of 5 to 22 days. Average urinary excretion of P/sup 32/, as a percentage of the initial dose to the end of 3 days for the entire series, was 14.3%, with limits of 6.4 and 18.7%. The corresponding 5-day average amounted to 17.8%, with limits of 7.5 and 22.5%. In the six patients treated orally, the average 3-day urinary excretion was 11.2% and for 5more » days was 14.2%. For the 11 patients treated intravenously, the average 3-day excretion was 16.1%, the average 5-day excretion 19.8%. The average fecal excretion as a percentage of the initial dose to the end of 3 days was 1.7%, with limits of 0.1 and 5.5%, and the average 5-day excretion was 2.5%, with limits 0.5 and 5.9%. In the orally treated fasting group the total stool excretion to the end of 3 days was 2.0 and 2.5% at the end of 5 days. Of the 10 polycythemia patients treated intravenously, the stool excretion to the end of 3 days was 1.5% and at 5 days 2.5%. Under fasting conditions (both before and after the administration of P/sup 32/) with little or no carrier added, the fecal excretion of P/sup 32/is small. Thus, the total excretion of P/sup 32/ does not differ significantly for oral and intravenous administration. Hence, despite contrary reports, it appears that under fasting conditions of administration it is not necessary to increase the oral dose of P/ sup 32/ to 4/3 of the intravenous dose in order to obtain equivalent absorption of the administered dose. It is concluded that the P/sup 32/ content of urine in the first 24 hr after therapy, by either route of administration, indicates whether or not a particular patient will retain the dose within normal limits. (BBB)« less

  8. Adoption of Total Neoadjuvant Therapy for Locally Advanced Rectal Cancer.

    PubMed

    Cercek, Andrea; Roxburgh, Campbell S D; Strombom, Paul; Smith, J Joshua; Temple, Larissa K F; Nash, Garrett M; Guillem, Jose G; Paty, Philip B; Yaeger, Rona; Stadler, Zsofia K; Seier, Kenneth; Gonen, Mithat; Segal, Neil H; Reidy, Diane L; Varghese, Anna; Shia, Jinru; Vakiani, Efsevia; Wu, Abraham J; Crane, Christopher H; Gollub, Marc J; Garcia-Aguilar, Julio; Saltz, Leonard B; Weiser, Martin R

    2018-03-22

    Treatment of locally advanced rectal (LARC) cancer involves chemoradiation, surgery, and chemotherapy. The concept of total neoadjuvant therapy (TNT), in which chemoradiation and chemotherapy are administered prior to surgery, has been developed to optimize delivery of effective systemic therapy aimed at micrometastases. To compare the traditional approach of preoperative chemoradiation (chemoRT) followed by postoperative adjuvant chemotherapy with the more recent TNT approach for LARC. A retrospective cohort analysis using Memorial Sloan Kettering Cancer Center (MSK) records from 2009 to 2015 was carried out. A total of 811 patients who presented with LARC (T3/4 or node-positive) were identified. Of the 811 patients, 320 received chemoRT with planned adjuvant chemotherapy and 308 received TNT (induction fluorouracil- and oxaliplatin-based chemotherapy followed by chemoRT). Treatment and outcome data for the 2 cohorts were compared. Dosing and completion of prescribed chemotherapy were assessed on the subset of patients who received all therapy at MSK. Of the 628 patients overall, 373 (59%) were men and 255 (41%) were women, with a mean (SD) age of 56.7 (12.9) years. Of the 308 patients in the TNT cohort, 181 (49%) were men and 127 (49%) were women. Of the 320 patients in the chemoRT with planned adjuvant chemotherapy cohort, 192 (60%) were men and 128 (40%) were women. Patients in the TNT cohort received greater percentages of the planned oxaliplatin and fluorouracil prescribed dose than those in the chemoRT with planned adjuvant chemotherapy cohort. The complete response (CR) rate, including both pathologic CR (pCR) in those who underwent surgery and sustained clinical CR (cCR) for at least 12 months posttreatment in those who did not undergo surgery, was 36% in the TNT cohort compared with 21% in the chemoRT with planned adjuvant chemotherapy cohort. Our findings provide additional support for the National Comprehensive Cancer Network (NCCN) guidelines that categorize TNT as a viable treatment strategy for rectal cancer. Our data suggest that TNT facilitates delivery of planned systemic therapy. Long-term follow-up will determine if this finding translates into improved survival. In addition, given its high CR rate, TNT may facilitate nonoperative treatment strategies aimed at organ preservation.

  9. Early blindness and coma during intrathecal chemotherapy for meningeal carcinomatosis.

    PubMed

    Boogerd, W; Moffie, D; Smets, L A

    1990-02-01

    A 35-year-old woman was treated with intraventricular methotrexate (MTX) with a total dose of 70 mg followed by cytosine arabinoside (Ara-C) with a total dose of 80 mg for meningeal metastasis of breast carcinoma. Radiation therapy was not given. Despite a response of the meningeal tumor the patient developed in the third week of MTX treatment a progressive visual loss and loss of consciousness which worsened during subsequent Ara-C treatment and led to death within 3 weeks. Postmortem examination revealed only minimal neoplastic infiltration of the meninges. Multiple foci of axonal degeneration and demyelination were found in the optic nerves and chiasm, the superficial layers of the brainstem, and spinal cord and to some extent in other cranial nerves and spinal nerve roots. The possible causes of this previously unreported early complication are discussed.

  10. In vitro transdentinal effect of low-level laser therapy

    NASA Astrophysics Data System (ADS)

    Oliveira, C. F.; Basso, F. G.; dos Reis, R. I.; Parreiras-e-Silva, L. T.; Lins, E. C.; Kurachi, C.; Hebling, J.; Bagnato, V. S.; de Souza Costa, C. A.

    2013-05-01

    Low-level laser therapy (LLLT) has been used for the treatment of dentinal hypersensitivity. However, the specific LLL dose and the response mechanisms of these cells to transdentinal irradiation have not yet been demonstrated. Therefore, this study evaluated the transdentinal effects of different LLL doses on stressed odontoblast-like pulp cells MDPC-23 seeded onto the pulpal side of dentin discs obtained from human third molars. The discs were placed in devices simulating in vitro pulp chambers and the whole set was placed in 24-well plates containing plain culture medium (DMEM). After 24 h incubation, the culture medium was replaced by fresh DMEM supplemented with either 5% (simulating a nutritional stress condition) or 10% fetal bovine serum (FBS). The cells were irradiated with doses of 15 and 25 J cm-2 every 24 h, totaling three applications over three consecutive days. The cells in the control groups were removed from the incubator for the same times as used in their respective experimental groups for irradiation, though without activating the laser source (sham irradiation). After 72 h of the last active or sham irradiation, the cells were evaluated with respect to succinic dehydrogenase (SDH) enzyme production (MTT assay), total protein (TP) expression, alkaline phosphatase (ALP) synthesis, reverse transcriptase polymerase chain reaction (RT-PCR) for collagen type 1 (Col-I) and ALP, and morphology (SEM). For both tests, significantly higher values were obtained for the 25 J cm-2 dose. Regarding SDH production, supplementation of the culture medium with 5% FBS provided better results. For TP and ALP expression, the 25 J cm-2 presented higher values, especially for the 5% FBS concentration (Mann-Whitney p < 0.05). Under the tested conditions, near infrared laser irradiation at 25 J cm-2 caused transdentinal biostimulation of odontoblast-like MDPC-23 cells.

  11. Intrathecal enzyme replacement therapy reduces lysosomal storage in the brain and meninges of the canine model of MPS I.

    PubMed

    Kakkis, E; McEntee, M; Vogler, C; Le, S; Levy, B; Belichenko, P; Mobley, W; Dickson, P; Hanson, S; Passage, M

    2004-01-01

    Enzyme replacement therapy (ERT) has been developed for several lysosomal storage disorders, including mucopolysaccharidosis I (MPS I), and is effective at reducing lysosomal storage in many tissues and in ameliorating clinical disease. However, intravenous ERT does not adequately treat storage disease in the central nervous system (CNS), presumably due to effects of the blood-brain barrier on enzyme distribution. To circumvent this barrier, we studied whether intrathecal (IT) recombinant human alpha-L-iduronidase (rhIDU) could penetrate and treat the brain and meninges. An initial dose-response study showed that doses of 0.46-4.14 mg of IT rhIDU successfully penetrated the brain of normal dogs and reached tissue levels 5.6 to 18.9-fold normal overall and 2.7 to 5.9-fold normal in deep brain sections lacking CSF contact. To assess the efficacy and safety in treating lysosomal storage disease, four weekly doses of approximately 1 mg of IT rhIDU were administered to MPS I-affected dogs resulting in a mean 23- and 300-fold normal levels of iduronidase in total brain and meninges, respectively. Quantitative glycosaminoglycan (GAG) analysis showed that the IT treatment reduced mean total brain GAG to normal levels and achieved a 57% reduction in meningeal GAG levels accompanied by histologic improvement in lysosomal storage in all cell types. The dogs did develop a dose-dependent immune response against the recombinant human protein and a meningeal lymphocytic/plasmacytic infiltrate. The IT route of ERT administration may be an effective way to treat the CNS disease in MPS I and could be applicable to other lysosomal storage disorders.

  12. Accelerated Total Lymphoid Irradiation-containing Salvage Regimen for Patients With Refractory and Relapsed Hodgkin Lymphoma: 20 Years of Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rimner, Andreas; Lovie, Shona; Hsu, Meier

    Purpose: We report the long-term results of integrated accelerated involved field radiation therapy (IFRT) followed by total lymphoid irradiation (TLI) as part of the high-dose salvage regimen followed by autologous bone marrow transplantation or autologous stem cell transplantation in patients with relapsed or refractory Hodgkin lymphoma (HL). Methods and Materials: From November 1985 to July 2008, 186 previously unirradiated patients with relapsed or refractory HL underwent salvage therapy on 4 consecutive institutional review board–approved protocols. All patients had biopsy-proven primary refractory or relapsed HL. After standard-dose salvage chemotherapy (SC), accelerated IFRT (18-20 Gy) was given to relapsed or refractory sites, followedmore » by TLI (15-18 Gy) and high-dose chemotherapy. Overall survival (OS) and event-free survival (EFS) were analyzed by Cox analysis and disease-specific survival (DSS) by competing-risk regression. Results: With a median follow-up period of 57 months among survivors, 5- and 10-year OS rates were 68% and 56%, respectively; 5- and 10-year EFS rates were 62% and 56%, respectively; and 5- and 10-year cumulative incidences of HL-related deaths were 21% and 29%, respectively. On multivariate analysis, complete response to SC was independently associated with improved OS and EFS. Primary refractory disease and extranodal disease were independently associated with poor DSS. Eight patients had grade 3 or higher cardiac toxicity, with 3 deaths. Second malignancies developed in 10 patients, 5 of whom died. Conclusions: Accelerated IFRT followed by TLI and high-dose chemotherapy is an effective, feasible, and safe salvage strategy for patients with relapsed or refractory HL with excellent long-term OS, EFS, and DSS. Complete response to SC is the most important prognostic factor.« less

  13. Therapeutic effect of high-dose three-dimensional conformal radiotherapy and conventional radiotherapy for non-small-cell lung cancer.

    PubMed

    Xu, Su-Jun; Shi, Yu-Sheng; Song, Hai-Chun; Chen, Long-Hua

    2002-10-01

    To improve the therapeutic effect of radiotherapy without increasing the risk of radiation injury in patients with non-small cell lung cancer (NSCLC). From August 1998 to August 1999, 135 patients with NSCLC received radiotherapy, of whom 62 were treated with high-dose three-dimensional conformal radiotherapy (3D-CRT) at the total dose of 48 to 64 Gy in 6 to 8 fractions implemented in a course of 2 to 3 weeks, 6 to 8 Gy for each fraction. The other 73 patients underwent conventional radiotherapy (CR) at the total dose of 60 to 70 Gy in 30 to 35 fractions completed in 6 to 7 weeks. Follow-up study was conducted in all the cases, and CT-scan or magnetic resonance imaging was performed once every 3 months after the therapy to assess the local control rate, survival rate, radiation-induced lung and esophageal injuries. Three months after radiation therapy, complete remission of the lesions was achieved in 44.9% (CR group) and 77.8% (3D-CRT group) of the cases with the efficacy rates of 94.4% and 100% respectively, showing significant differences between the 2 groups (P<0.01). The 1- and 2-year survival rate of the patients in the 2 groups were 42.5% vs 77.8% and 30.1% vs 48.6% respectively, also with significant differences between the 2 groups (P<0.01). Significant difference also occurred in the 1- and 2-year local control rates between the 2 groups, but not in the incidences of radiation-induced lung and esophageal injuries. 3D-CRT may yield better therapeutic effect than CR does and has comparable safety with the latter.

  14. Photobiomodulation Therapy on Physiological and Performance Parameters During Running Tests: Dose-Response Effects.

    PubMed

    Dellagrana, Rodolfo André; Rossato, Mateus; Sakugawa, Raphael Luiz; Baroni, Bruno Mafredini; Diefenthaeler, Fernando

    2018-02-22

    This study was aimed at verifying effects of photobiomodulation therapy (PBMT) with different energy doses (15, 30, and 60 J per site) on physiological and performance parameters during running tests. Fifteen male recreational runners participated in a crossover, randomised, double-blind, and placebo-controlled trial. They performed testing protocol in 5 sessions with different treatments: control, placebo, and PBMT with 15, 30 or 60 J per site (14 sites in each lower limb). Physiological and performance variables were assessed during submaximal (at 8 km·h-1 and 9 km·h-1) and maximal running tests. PBMT with 30 J significantly (p<0.05) improved running economy (RE) at 8 and 9 km·h-1 (3.01% and 3.03%, respectively), rate of perceived exertion (RPE) at 8 km·h-1 (7.86%), velocity at VO2MAX (3.07%), peak of velocity (PV) (1.49%), and total time to exhaustion (TTE) (3.41%) compared to placebo. PBMT with 15 J improved RE at 9 km·h-1 (2.98%), RPE at 8 km·h-1 (4.80%), PV (1.33%), TTE (3.06%), and total distance (4.01%) compared to the placebo; while PBMT with 60 J only increased RE at 9 km·h-1 (3.87%) compared to placebo. All PBMT doses positively affected physiological and/or performance parameters; however magnitude-based inference reported that PBMT applied with 30 J led to more beneficial effects than 15 J and 60 J.

  15. Pretransplant Tacrolimus Dose Requirements Predict Early Posttransplant Dose Requirements in Blood Group AB0-Incompatible Kidney Transplant Recipients.

    PubMed

    Shuker, Nauras; de Man, Femke M; de Weerd, Annelies E; van Agteren, Madelon; Weimar, Willem; Betjes, Michiel G H; van Gelder, Teun; Hesselink, Dennis A

    2016-04-01

    The aim of this study was to investigate whether pretransplant tacrolimus (Tac) dose requirements of patients scheduled to undergo living donor kidney transplantation correlate with posttransplantation dose requirements. The predictive value of Tac dose requirements (defined as the ratio of the Tac predose concentration, C0, divided by the total daily Tac dose, D) pretransplantation on this same parameter posttransplantation was assessed retrospectively in a cohort of 57 AB0-incompatible kidney transplant recipients. These patients started immunosuppressive therapy 14 days before transplant surgery. All patients were using a stable dose of glucocorticoids and were at steady-state Tac exposure before transplantation. Tac dose requirements immediately before transplantation (C0/Dbefore) explained 63% of the Tac dose requirements on day 3 after transplantation: r = 0.633 [F (1, 44) = 75.97, P < 0.01]. No other clinical and demographic variables predicted Tac dose requirements early after transplantation. Steady-state Tac dose requirement before transplantation largely predicted posttransplantation Tac dose requirements in AB0-incompatible kidney transplant recipients. The importance of this finding is that the posttransplantation Tac dose can be individualized based on a patient's pretransplantation Tac concentration/dose ratio. Pretransplant Tac phenotyping therefore has the potential to improve transplantation outcomes.

  16. [Combined palliative hypofractionated radiation and carboplatin chemotherapy of intranasal tumours in dogs].

    PubMed

    Schwietzer, A; Kessler, M; Kandel-Tschiederer, B

    2012-10-17

    Combination therapy of intranasal tumours in dogs with palliative 60 cobalt radiation and carboplatin chemotherapy. Twenty-five dogs with intranasal tumours were treated in the Hofheim Veterinary Hospital (Germany) from 2004 to 2006 with a total radiation dose of 24Gy (3 fractions of 8 Gy on days 0, 7 and 21) and five doses of Carboplatin (270-300 mg/m² BSA i.v. every 21-28 days). In 88% patients, clinical symptoms subsided partially or completely resulting in improvement in quality of life. Computed tomography revealed partial (5/25) or complete (5/25) tumour remissions. Chemotherapy was well tolerated. Radiation therapy caused no or minimal side effects except for 3 dogs (12%), which experienced serious ocular side effects resulting in loss of vision of the affected eye and one dog with epileptic seizures. Survival times ranged from 10-639 days with a median of 156 days. There was no statistically significant correlation between the parameters breed, age, sex, brain invasion or tumour stage and survival time or progression free interval. Survival time and progression free interval were significantly correlated with the degree of tumour remission. It can be concluded from this study that palliative radiation therapy combined with chemotherapy results in excellent palliation of clinical symptoms and acceptable survival times. There was no advantage of combined therapy (radiation with carboplatin) when compared to literature data on results of radiation therapy alone.

  17. Effects of saxagliptin add-on therapy to insulin on blood glycemic fluctuations in patients with type 2 diabetes

    PubMed Central

    Li, Feng-fei; Jiang, Lan-lan; Yan, Reng-na; Zhu, Hong-hong; Zhou, Pei-hua; Zhang, Dan-feng; Su, Xiao-fei; Wu, Jin-dan; Ye, Lei; Ma, Jian-hua

    2016-01-01

    Abstract Background: To investigate whether saxagliptin add-on therapy to continuous subcutaneous insulin infusion (CSII) further improve blood glycemic control than CSII therapy in patients with newly diagnosed type 2 diabetes (T2D). Methods: This was a single-center, randomized, control, open-labeled trial. Newly diagnosed T2D patients were recruited between February 2014 and December 2015. Subjects were divided into saxagliptin add-on therapy to CSII group (n = 31) and CSII therapy group (n = 38). The treatment was maintained for 4 weeks. Oral glucose tolerance test was performed at baseline. Serum samples were obtained before and 30 and 120 minutes after oral administration for glucose, insulin, and C-peptide determination. Continuous glucose monitoring (CGM) was performed before and endpoint. Results: A total of 69 subjects were admitted. After 4-week therapy, CGM data showed that patients with saxagliptin add-on therapy exhibited further improvement of mean amplitude glycemic excursion (MAGE), the incremental area under curve of plasma glucose >7.8 and 10 mmol/L compared with that of control group. In addition, the hourly mean blood glucose concentrations, especially between 0000 and 0600 in patient with saxagliptin add-on therapy, were significantly lower compared with that of the control patients. Furthermore, patients in saxagliptin add-on group needed lower insulin dose to maintain euglycemic control. In addition, severe hypoglycemic episode was not observed from any group. Conclusion: Saxagliptin add-on therapy to insulin had the ability of further improve blood glycemic controlling, with lower insulin dose required by patients with T2D to maintain euglycemic controlling. PMID:27787387

  18. Effects of saxagliptin add-on therapy to insulin on blood glycemic fluctuations in patients with type 2 diabetes: A randomized, control, open-labeled trial.

    PubMed

    Li, Feng-Fei; Jiang, Lan-Lan; Yan, Reng-Na; Zhu, Hong-Hong; Zhou, Pei-Hua; Zhang, Dan-Feng; Su, Xiao-Fei; Wu, Jin-Dan; Ye, Lei; Ma, Jian-Hua

    2016-10-01

    To investigate whether saxagliptin add-on therapy to continuous subcutaneous insulin infusion (CSII) further improve blood glycemic control than CSII therapy in patients with newly diagnosed type 2 diabetes (T2D). This was a single-center, randomized, control, open-labeled trial. Newly diagnosed T2D patients were recruited between February 2014 and December 2015. Subjects were divided into saxagliptin add-on therapy to CSII group (n = 31) and CSII therapy group (n = 38). The treatment was maintained for 4 weeks. Oral glucose tolerance test was performed at baseline. Serum samples were obtained before and 30 and 120 minutes after oral administration for glucose, insulin, and C-peptide determination. Continuous glucose monitoring (CGM) was performed before and endpoint. A total of 69 subjects were admitted. After 4-week therapy, CGM data showed that patients with saxagliptin add-on therapy exhibited further improvement of mean amplitude glycemic excursion (MAGE), the incremental area under curve of plasma glucose >7.8 and 10 mmol/L compared with that of control group. In addition, the hourly mean blood glucose concentrations, especially between 0000 and 0600 in patient with saxagliptin add-on therapy, were significantly lower compared with that of the control patients. Furthermore, patients in saxagliptin add-on group needed lower insulin dose to maintain euglycemic control. In addition, severe hypoglycemic episode was not observed from any group. Saxagliptin add-on therapy to insulin had the ability of further improve blood glycemic controlling, with lower insulin dose required by patients with T2D to maintain euglycemic controlling.

  19. Long-term safety and efficacy of AAV gene therapy in the canine model of glycogen storage disease type Ia.

    PubMed

    Lee, Young Mok; Conlon, Thomas J; Specht, Andrew; Coleman, Kirsten E; Brown, Laurie M; Estrella, Ana M; Dambska, Monika; Dahlberg, Kathryn R; Weinstein, David A

    2018-05-25

    Viral mediated gene therapy has progressed after overcoming early failures, and gene therapy has now been approved for several conditions in Europe and the USA. Glycogen storage disease (GSD) type Ia, caused by a deficiency of glucose-6-phosphatase-α, has been viewed as an outstanding candidate for gene therapy. This follow-up report describes the long-term outcome for the naturally occurring GSD-Ia dogs treated with rAAV-GPE-hG6PC-mediated gene therapy. A total of seven dogs were treated with rAAV-GPE-hG6PC-mediated gene therapy. The first four dogs were treated at birth, and three dogs were treated between 2 and 6 months of age to assess the efficacy and safety in animals with mature livers. Blood and urine samples, radiographic studies, histological evaluation, and biodistribution were assessed. Gene therapy improved survival in the GSD-Ia dogs. With treatment, the biochemical studies normalized for the duration of the study (up to 7 years). None of the rAAV-GPE-hG6PC-treated dogs had focal hepatic lesions or renal abnormalities. Dogs treated at birth required a second dose of rAAV after 2-4 months; gene therapy after hepatic maturation resulted in improved efficacy after a single dose. rAAV-GPE-hG6PC treatment in GSD-Ia dogs was found to be safe and efficacious. GSD-Ia is an attractive target for human gene therapy since it is a monogenic disorder with limited tissue involvement. Blood glucose and lactate monitoring can be used to assess effectiveness and as a biomarker of success. GSD-Ia can also serve as a model for other hepatic monogenic disorders.

  20. Long-term results of children with acute myeloid leukemia: a report of three consecutive Phase III trials by the Children's Cancer Group: CCG 251, CCG 213 and CCG 2891.

    PubMed

    Smith, F O; Alonzo, T A; Gerbing, R B; Woods, W G; Arceci, R J

    2005-12-01

    The Children's Cancer Group (CCG) conducted three Phase III prospective clinical trials for children with de novo acute myeloid leukemia between the years 1979 and 1995. A total of 1903 eligible children ages birth to 21 years of age were enrolled on CCG 251 (n=485), CCG 213 (n=532) and CCG 2891 (n=886). Follow-up is ongoing, with medians of 7.9, 10.9 and 8.6 years, respectively. These three clinical trials developed dose- and time-intensive induction regimens based upon high-dose cytarabine and daunomycin and randomly assigned patients to allogeneic bone marrow transplantation in first remission if an HLA-matched related donor was identified. Despite dose- and time-intensive induction regimens, remission induction rates remained relatively stable at 77-78%. However, overall survival, event-free survival and disease-free survival (DFS) increased for patients receiving intensive-timing induction therapy in comparison to patients who received standard-timing induction, regardless of the type of postremission therapy. Outcomes were best for patients receiving intensive-timing induction followed by matched related donor allogeneic transplantation with DFS of 65+/-9% at 6 years. These three clinical trials have established a strong foundation for the development of future studies focusing on further risk group stratification and the development of novel, molecularly-targeted therapies.

  1. Pre-emptive rituximab for Epstein-Barr virus reactivation after haplo-hematopoietic stem cell transplantation.

    PubMed

    Kobayashi, Shogo; Sano, Hideki; Mochizuki, Kazuhiro; Ohara, Yoshihiro; Takahashi, Nobuhisa; Ohto, Hitoshi; Kikuta, Atsushi

    2017-09-01

    Epstein-Barr virus-related post-transplantation lymphoproliferative disease (EBV-PTLD) is a serious complication in hematopoietic stem cell transplantation (HSCT) recipients. We conducted a retrospective study to investigate the incidence and potential risk factors for EBV reactivation and to assess the efficacy of the management of EBV reactivation with pre-emptive rituximab in children who had T-cell-replete haploidentical HSCT (TCR-haplo-SCT) with low-dose anti-thymocyte globulin (ATG). EBV-DNA level in peripheral blood (PB) was measured when suspected EBV reactivation were observed. When the EBV-DNA level in PB increased to >1,000 copies/10 6 peripheral blood mononuclear cells (PBMC), patients were pre-emptively treated with rituximab (375 mg/m 2 /dose). A total of 19 (50%) of 38 patients received rituximab infusion at a median time of 56 days after HSCT (range, 17-270 days). The median viral load at initiation of therapy was 2,900 copies/10 6 PBMC (range, 1,000-650 000). Pre-emptive therapy was started after a median of 2 days (range, 0-7 days). The median number of weekly treatment cycles was 2 (range, 1-3). None of the patients developed PTLD or other EBV-associated diseases. Pre-emptive rituximab therapy could be a useful strategy for EBV-PTLD in TCR-haplo-SCT recipients with low-dose ATG. © 2017 Japan Pediatric Society.

  2. Impact of dose intensified salvage radiation therapy on urinary continence recovery after radical prostatectomy: Results of the randomized trial SAKK 09/10.

    PubMed

    Ghadjar, Pirus; Hayoz, Stefanie; Bernhard, Jürg; Zwahlen, Daniel R; Stein, Jürgen; Hölscher, Tobias; Gut, Philipp; Polat, Bülent; Hildebrandt, Guido; Müller, Arndt-Christian; Putora, Paul Martin; Papachristofilou, Alexandros; Schär, Corinne; Dal Pra, Alan; Biaggi Rudolf, Christine; Wust, Peter; Aebersold, Daniel M; Thalmann, George N

    2018-02-01

    Adjuvant radiation therapy (aRT) after radical prostatectomy (RP) is associated with impaired urinary continence recovery as compared to surveillance. Less is known regarding the effect of salvage radiation therapy (sRT) dose intensification on continence outcomes. Urinary continence recovery was investigated within a multicentre randomized trial in biochemically recurrent prostate cancer patients who received either 64 Gy (32 fractions) or 70 Gy (35 fractions) sRT. Incontinence was assessed using Common Toxicity Criteria for Adverse Events v4.0 at baseline, at the end of sRT and 3 months afterward. Quality of life (QoL) was assessed with the EORTC QoL questionnaires C30 and PR25 at baseline and 3 months after completion of sRT. A total of 344 patients were evaluable. At baseline 233 (68%) of patients were fully continent and 14% in both arms became incontinent three months after treatment. Of the remaining 111 (32%) patients being incontinent at baseline, continence recovery was achieved 3 months after sRT by 44% vs. 41% with 64 vs. 70 Gy, respectively (p = 0.8). This analysis is limited by its short follow-up. Dose intensification of sRT had no impact on early urinary continence recovery or prevalence of de novo incontinence. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. A vancomycin drug use evaluation and economic analysis in a cancer treatment centre.

    PubMed

    Dranitsaris, G; Pilla, N J; McGreer, A

    1994-04-01

    Princess Margaret Hospital is a 140-bed university affiliated cancer treatment centre. Vancomycin was the only formulary agent available for the treatment of methicillin-resistant gram-positive organisms. The high cost and potential toxicity of this drug warranted a closer examination of its use. The purpose of this study was to evaluate vancomycin use and to determine the economic impact when it was used contrary to newly developed hospital guidelines. A sample of 100 vancomycin orders was randomly selected from all prescriptions filled in 1992. The indication, dose, and duration of therapy for each order were compared against the hospital guidelines. The cost savings associated with altering the sample of prescriptions to meet hospital guidelines were then determined. Nine percent of the prescriptions were for nonapproved indications. The actual dose used did not meet criteria in 32% of cases and the length of therapy was beyond the approved duration in 45% of the orders. If the cases had been altered to meet the guidelines then a total savings of $13,581 would have been realized. The projected savings for the entire year (1992) would have been $100,907. The critical problem areas in vancomycin prescribing were the duration of therapy and dose. The results have provided the impetus to initiate a hospital wide prospective Drug Utilization Evaluation (DUE) study to optimize vancomycin prescribing. The program costs would be easily covered by the expected savings.

  4. Bladder radiotherapy treatment: A retrospective comparison of 3-dimensional conformal radiotherapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy plans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pasciuti, Katia, E-mail: k.pasciuti@virgilio.it; Kuthpady, Shrinivas; Anderson, Anne

    To examine tumor's and organ's response when different radiotherapy plan techniques are used. Ten patients with confirmed bladder tumors were first treated using 3-dimensional conformal radiotherapy (3DCRT) and subsequently the original plans were re-optimized using the intensity-modulated radiation treatment (IMRT) and volumetric-modulated arc therapy (VMAT)-techniques. Targets coverage in terms of conformity and homogeneity index, TCP, and organs' dose limits, including integral dose analysis were evaluated. In addition, MUs and treatment delivery times were compared. Better minimum target coverage (1.3%) was observed in VMAT plans when compared to 3DCRT and IMRT ones confirmed by a statistically significant conformity index (CI) results.more » Large differences were observed among techniques in integral dose results of the femoral heads. Even if no statistically significant differences were reported in rectum and tissue, a large amount of energy deposition was observed in 3DCRT plans. In any case, VMAT plans provided better organs and tissue sparing confirmed also by the normal tissue complication probability (NTCP) analysis as well as a better tumor control probability (TCP) result. Our analysis showed better overall results in planning using VMAT techniques. Furthermore, a total time reduction in treatment observed among techniques including gantry and collimator rotation could encourage using the more recent one, reducing target movements and patient discomfort.« less

  5. Dopamine in the management of shock.

    PubMed Central

    Thompson, W L

    1977-01-01

    Shock is a syndrome with serious prognostic implications--the harbinger of death. Hypoperfusion of essential organs is common, though total blood flow may be significantly greater than normal. Specific therapy is directed to the specific inciting event--infection, abscess, tamponade, &c. Symptomatic therapy keeps the patient alive until we discover the specific problem or until he recovers spontaneously. The intravascular volume must be carefully monitored and corrected, using the pulmonary wedge pressure as the principal guide, and colloid osmotic pressure must be maintained. If the patient does not respond to volume augmentation alone then inotropic drugs may be needed, and of these dopamine is a selective vasodilator which redirects blood flow to the critical organs. The outstanding challenge in shock is the maldistribution of perfusion in the microvasculature. Although this may be ameliorated by the early administration of large doses of glucocorticoids, there is little convincing that these drugs constitute more than supportive therapy. Of greatest importance is reevaluation, reevaluation, and reevaluation. The patient in shock becomes a new patient every five minutes. Drugs that formerly worked, doses previously optimal--these are no guide because the situation changes so rapidly. The principles of management are to monitor vital functions, constantly vary drugs and doses, and continually attempt to put right all the parameters measured. This strategy will be more effective when we know what parameters to measure. PMID:264200

  6. An in vivo dose verification method for SBRT-VMAT delivery using the EPID.

    PubMed

    McCowan, P M; Van Uytven, E; Van Beek, T; Asuni, G; McCurdy, B M C

    2015-12-01

    Radiation treatments have become increasingly more complex with the development of volumetric modulated arc therapy (VMAT) and the use of stereotactic body radiation therapy (SBRT). SBRT involves the delivery of substantially larger doses over fewer fractions than conventional therapy. SBRT-VMAT treatments will strongly benefit from in vivo patient dose verification, as any errors in delivery can be more detrimental to the radiobiology of the patient as compared to conventional therapy. Electronic portal imaging devices (EPIDs) are available on most commercial linear accelerators (Linacs) and their documented use for dosimetry makes them valuable tools for patient dose verification. In this work, the authors customize and validate a physics-based model which utilizes on-treatment EPID images to reconstruct the 3D dose delivered to the patient during SBRT-VMAT delivery. The SBRT Linac head, including jaws, multileaf collimators, and flattening filter, were modeled using Monte Carlo methods and verified with measured data. The simulation provides energy spectrum data that are used by their "forward" model to then accurately predict fluence generated by a SBRT beam at a plane above the patient. This fluence is then transported through the patient and then the dose to the phosphor layer in the EPID is calculated. Their "inverse" model back-projects the EPID measured focal fluence to a plane upstream of the patient and recombines it with the extra-focal fluence predicted by the forward model. This estimate of total delivered fluence is then forward projected onto the patient's density matrix and a collapsed cone convolution algorithm calculates the dose delivered to the patient. The model was tested by reconstructing the dose for two prostate, three lung, and two spine SBRT-VMAT treatment fractions delivered to an anthropomorphic phantom. It was further validated against actual patient data for a lung and spine SBRT-VMAT plan. The results were verified with the treatment planning system (TPS) (ECLIPSE AAA) dose calculation. The SBRT-VMAT reconstruction model performed very well when compared to the TPS. A stringent 2%/2 mm χ-comparison calculation gave pass rates better than 91% for the prostate plans, 88% for the lung plans, and 86% for the spine plans for voxels containing 80% or more of the prescribed dose. Patient data were 86% for the lung and 95% for the spine. A 3%/3 mm χ-comparison was also performed and gave pass rates better than 93% for all plan types. The authors have customized and validated a robust, physics-based model that calculates the delivered dose to a patient for SBRT-VMAT delivery using on-treatment EPID images. The accuracy of the results indicates that this approach is suitable for clinical implementation. Future work will incorporate this model into both offline and real-time clinical adaptive radiotherapy.

  7. Proton therapy to the subdiaphragmatic region in the management of patients with Hodgkin lymphoma.

    PubMed

    Sachsman, Suzanne; Hoppe, Bradford S; Mendenhall, Nancy P; Holtzman, Adam; Li, Zuofeng; Slayton, William; Joyce, Mike; Sandler, Eric; Flampouri, Stella

    2015-07-01

    Twelve consecutive patients with classical Hodgkin lymphoma (HL) involving diaphragmatic or subdiaphragmatic regions were treated on an institutional review board-approved outcomes tracking protocol. All patients underwent treatment with proton therapy following chemotherapy and had comparative three-dimensional conformal photon radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT) plans to evaluate differences in dose to organs at risk (OARs). Among the cohort, stomach doses with 3DCRT, IMRT and proton therapy were 21 Gy (median), 14 Gy and 6 Gy, respectively. Median dose reductions with proton therapy compared with 3DCRT and IMRT were 13 Gy (p = 0.0022) and 8 Gy (p = 0.0022) for the stomach. Additionally, there was significant dose reduction using proton therapy for the liver, pancreas, bowel, left kidney and right kidney. Proton therapy reduces the dose to the stomach, liver, pancreas, small bowel and kidneys compared with 3DCRT or IMRT in patients with HL requiring abdominal radiotherapy. These dose reductions are expected to translate into lower risks of secondary cancers and other late toxicities in survivors of HL.

  8. Bilateral implant reconstruction does not affect the quality of postmastectomy radiation therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, Alice Y., E-mail: hoa1234@mskcc.org; Patel, Nisha; Ohri, Nisha

    To determine if the presence of bilateral implants, in addition to other anatomic and treatment-related variables, affects coverage of the target volume and dose to the heart and lung in patients receiving postmastectomy radiation therapy (PMRT). A total of 197 consecutive women with breast cancer underwent mastectomy and immediate tissue expander (TE) placement, with or without exchange for a permanent implant (PI) before radiation therapy at our center. PMRT was delivered with 2 tangential beams + supraclavicular lymph node field (50 Gy). Patients were grouped by implant number: 51% unilateral (100) and 49% bilateral (97). The planning target volume (PTV)more » (defined as implant + chest wall + nodes), heart, and ipsilateral lung were contoured and the following parameters were abstracted from dose-volume histogram (DVH) data: PTV D{sub 95%} > 98%, Lung V{sub 20}Gy > 30%, and Heart V{sub 25}Gy > 5%. Univariate (UVA) and multivariate analyses (MVA) were performed to determine the association of variables with these parameters. The 2 groups were well balanced for implant type and volume, internal mammary node (IMN) treatment, and laterality. In the entire cohort, 90% had PTV D{sub 95%} > 98%, indicating excellent coverage of the chest wall. Of the patients, 27% had high lung doses (V{sub 20}Gy > 30%) and 16% had high heart doses (V{sub 25}Gy > 5%). No significant factors were associated with suboptimal PTV coverage. On MVA, IMN treatment was found to be highly associated with high lung and heart doses (both p < 0.0001), but implant number was not (p = 0.54). In patients with bilateral implants, IMN treatment was the only predictor of dose to the contralateral implant (p = 0.001). In conclusion, bilateral implants do not compromise coverage of the target volume or increase lung and heart dose in patients receiving PMRT. The most important predictor of high lung and heart doses in patients with implant-based reconstruction, whether unilateral or bilateral, is treatment of the IMNs. Refinement of radiation techniques in reconstructed patients who require comprehensive nodal irradiation is warranted.« less

  9. Secondary neutron spectrum from 250-MeV passively scattered proton therapy: measurement with an extended-range Bonner sphere system.

    PubMed

    Howell, Rebecca M; Burgett, E A

    2014-09-01

    Secondary neutrons are an unavoidable consequence of proton therapy. While the neutron dose is low compared to the primary proton dose, its presence and contribution to the patient dose is nonetheless important. The most detailed information on neutrons includes an evaluation of the neutron spectrum. However, the vast majority of the literature that has reported secondary neutron spectra in proton therapy is based on computational methods rather than measurements. This is largely due to the inherent limitations in the majority of neutron detectors, which are either not suitable for spectral measurements or have limited response at energies greater than 20 MeV. Therefore, the primary objective of the present study was to measure a secondary neutron spectrum from a proton therapy beam using a spectrometer that is sensitive to neutron energies over the entire neutron energy spectrum. The authors measured the secondary neutron spectrum from a 250-MeV passively scattered proton beam in air at a distance of 100 cm laterally from isocenter using an extended-range Bonner sphere (ERBS) measurement system. Ambient dose equivalent H*(10) was calculated using measured fluence and fluence-to-ambient dose equivalent conversion coefficients. The neutron fluence spectrum had a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate energy continuum between the thermal and evaporation peaks. The H*(10) was dominated by the neutrons in the evaporation peak because of both their high abundance and the large quality conversion coefficients in that energy interval. The H*(10) 100 cm laterally from isocenter was 1.6 mSv per proton Gy (to isocenter). Approximately 35% of the dose equivalent was from neutrons with energies ≥20 MeV. The authors measured a neutron spectrum for external neutrons generated by a 250-MeV proton beam using an ERBS measurement system that was sensitive to neutrons over the entire energy range being measured, i.e., thermal to 250 MeV. The authors used the neutron fluence spectrum to demonstrate experimentally the contribution of neutrons with different energies to the total dose equivalent and in particular the contribution of high-energy neutrons (≥20 MeV). These are valuable reference data that can be directly compared with Monte Carlo and experimental data in the literature.

  10. Secondary neutron spectrum from 250-MeV passively scattered proton therapy: Measurement with an extended-range Bonner sphere system

    PubMed Central

    Howell, Rebecca M.; Burgett, E. A.

    2014-01-01

    Purpose: Secondary neutrons are an unavoidable consequence of proton therapy. While the neutron dose is low compared to the primary proton dose, its presence and contribution to the patient dose is nonetheless important. The most detailed information on neutrons includes an evaluation of the neutron spectrum. However, the vast majority of the literature that has reported secondary neutron spectra in proton therapy is based on computational methods rather than measurements. This is largely due to the inherent limitations in the majority of neutron detectors, which are either not suitable for spectral measurements or have limited response at energies greater than 20 MeV. Therefore, the primary objective of the present study was to measure a secondary neutron spectrum from a proton therapy beam using a spectrometer that is sensitive to neutron energies over the entire neutron energy spectrum. Methods: The authors measured the secondary neutron spectrum from a 250-MeV passively scattered proton beam in air at a distance of 100 cm laterally from isocenter using an extended-range Bonner sphere (ERBS) measurement system. Ambient dose equivalent H*(10) was calculated using measured fluence and fluence-to-ambient dose equivalent conversion coefficients. Results: The neutron fluence spectrum had a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate energy continuum between the thermal and evaporation peaks. The H*(10) was dominated by the neutrons in the evaporation peak because of both their high abundance and the large quality conversion coefficients in that energy interval. The H*(10) 100 cm laterally from isocenter was 1.6 mSv per proton Gy (to isocenter). Approximately 35% of the dose equivalent was from neutrons with energies ≥20 MeV. Conclusions: The authors measured a neutron spectrum for external neutrons generated by a 250-MeV proton beam using an ERBS measurement system that was sensitive to neutrons over the entire energy range being measured, i.e., thermal to 250 MeV. The authors used the neutron fluence spectrum to demonstrate experimentally the contribution of neutrons with different energies to the total dose equivalent and in particular the contribution of high-energy neutrons (≥20 MeV). These are valuable reference data that can be directly compared with Monte Carlo and experimental data in the literature. PMID:25186404

  11. Fred: a GPU-accelerated fast-Monte Carlo code for rapid treatment plan recalculation in ion beam therapy

    NASA Astrophysics Data System (ADS)

    Schiavi, A.; Senzacqua, M.; Pioli, S.; Mairani, A.; Magro, G.; Molinelli, S.; Ciocca, M.; Battistoni, G.; Patera, V.

    2017-09-01

    Ion beam therapy is a rapidly growing technique for tumor radiation therapy. Ions allow for a high dose deposition in the tumor region, while sparing the surrounding healthy tissue. For this reason, the highest possible accuracy in the calculation of dose and its spatial distribution is required in treatment planning. On one hand, commonly used treatment planning software solutions adopt a simplified beam-body interaction model by remapping pre-calculated dose distributions into a 3D water-equivalent representation of the patient morphology. On the other hand, Monte Carlo (MC) simulations, which explicitly take into account all the details in the interaction of particles with human tissues, are considered to be the most reliable tool to address the complexity of mixed field irradiation in a heterogeneous environment. However, full MC calculations are not routinely used in clinical practice because they typically demand substantial computational resources. Therefore MC simulations are usually only used to check treatment plans for a restricted number of difficult cases. The advent of general-purpose programming GPU cards prompted the development of trimmed-down MC-based dose engines which can significantly reduce the time needed to recalculate a treatment plan with respect to standard MC codes in CPU hardware. In this work, we report on the development of fred, a new MC simulation platform for treatment planning in ion beam therapy. The code can transport particles through a 3D voxel grid using a class II MC algorithm. Both primary and secondary particles are tracked and their energy deposition is scored along the trajectory. Effective models for particle-medium interaction have been implemented, balancing accuracy in dose deposition with computational cost. Currently, the most refined module is the transport of proton beams in water: single pencil beam dose-depth distributions obtained with fred agree with those produced by standard MC codes within 1-2% of the Bragg peak in the therapeutic energy range. A comparison with measurements taken at the CNAO treatment center shows that the lateral dose tails are reproduced within 2% in the field size factor test up to 20 cm. The tracing kernel can run on GPU hardware, achieving 10 million primary s-1 on a single card. This performance allows one to recalculate a proton treatment plan at 1% of the total particles in just a few minutes.

  12. Intensity-Modulated Proton Therapy for Elective Nodal Irradiation and Involved-Field Radiation in the Definitive Treatment of Locally Advanced Non-Small Cell Lung Cancer: A Dosimetric Study

    PubMed Central

    Kesarwala, Aparna H.; Ko, Christine J.; Ning, Holly; Xanthopoulos, Eric; Haglund, Karl E.; O’Meara, William P.; Simone, Charles B.; Rengan, Ramesh

    2015-01-01

    Background Photon involved-field radiation therapy (IFRT), the standard for locally advanced non-small cell lung cancer (LA-NSCLC), results in favorable outcomes without increased isolated nodal failures, perhaps from scattered dose to elective nodal stations. Given the high conformality of intensity-modulated proton therapy (IMPT), proton IFRT could increase nodal failures. We investigated the feasibility of IMPT for elective nodal irradiation (ENI) in LA-NSCLC. Materials and Methods IMPT IFRT plans were generated to the same total dose of 66.6–72 Gy received by 20 LA-NSCLC patients treated with photon IFRT. IMPT ENI plans were generated to 46 CGE to elective nodal (EN) planning treatment volumes (PTV) plus 24 CGE to involved field (IF)-PTVs. Results Proton IFRT and ENI both improved D95 involved field (IF)-PTV coverage by 4% (p<0.01) compared to photon IFRT. All evaluated dosimetric parameters improved significantly with both proton plans. Lung V20 and mean lung dose decreased 18% (p<0.01) and 36% (p<0.01), respectively, with proton IFRT and 11% (p=0.03) and 26% (p<0.01) with ENI. Mean esophagus dose decreased 16% with IFRT and 12% with ENI; heart V25 decreased 63% with both (all p<0.01). Conclusions This study demonstrates the feasibility of IMPT for LA-NSCLC ENI. Potential decreased toxicity indicates IMPT could allow ENI while maintaining a favorable therapeutic ratio compared to photon IFRT. PMID:25604729

  13. Ozone therapy as add-on treatment in fibromyalgia management by rectal insufflation: an open-label pilot study.

    PubMed

    Hidalgo-Tallón, Javier; Menéndez-Cepero, Silvia; Vilchez, Juan S; Rodríguez-López, Carmen M; Calandre, Elena P

    2013-03-01

    The objectives of this study were to evaluate the effectiveness and tolerability of ozone therapy by rectal insufflation as add-on therapy in fibromyalgia management. Patients with fibromyalgia received 24 sessions of ozone therapy during a 12-week period. At each session, the administered dose of ozone was 8 mg (200 mL of gas, at a concentration of 40 μg/mL). Ozone sessions were given 5 days a week during the first 2 weeks, twice a week from weeks 3-6, and weekly from weeks 7-12. Fibromyalgia Impact Questionnaire (FIQ) was the main outcome measure, and was administered at baseline and at weeks 4, 8, and 12. Secondary outcome measures, administered at baseline and at endpoint, were the Pittsburgh Sleep Quality Index, the Beck Depression Inventory, the State and Trait Anxiety Inventory, and the SF-12, the abbreviated form of the Short Form Health Survey. Emergent adverse reactions to treatment were recorded. FIQ total scores decreased significantly during the study period, with the decrease being observed in the first 4 weeks of the study. Significant improvement was also seen both in depression scores and in the Physical Summary Score of the SF-12. Transient meteorism after ozone therapy sessions was the most frequently reported side-effect. At the dose and number of sessions used in this study, ozone therapy by rectal insufflation seems to be beneficial for physical symptoms and depression of fibromyalgia.

  14. Uterine Development After Estrogen Replacement Therapy in Women with Different Etiologies of Primary Hypogonadism.

    PubMed

    Kim, Hyo Jeong; Lee, Dong-Yun; Yoon, Byung-Koo; Choi, DooSeok

    2016-08-01

    To evaluate uterine development with estrogen replacement therapy in patients with primary amenorrhea due to hypogonadism. Retrospective study. Thirty-five women. Women who were younger than 20 years of age and who had primary amenorrhea and an immaturely shaped uterus were included. Changes in uterine cross-sectional area (UXA) and uterine maturity in pelvic ultrasound after 2 year of estrogen replacement therapy were assessed on the basis of the etiology of primary hypogonadism. Patients were classified into three groups according to the etiology of primary hypogonadism: Turner syndrome (n = 19), hypogonadotropic hypogonadism after brain surgery (n = 10), and premature ovarian insufficiency after cancer treatment (n = 6). Overall, the mean UXA significantly increased (from 3.1 ± 1.8 to 11.6 ± 4.9 cm(2)) after estrogen replacement therapy (P < .001), but the final UXA was significantly smaller in patients with premature ovarian insufficiency compared with other etiologies. In logistic regression analysis, etiology and the cumulative dose of estrogen were associated with uterine maturation (P = .011 and .004, respectively). Estrogen replacement therapy induced growth of the uterus in patients with primary hypogonadism. However, the response to estrogen replacement therapy varied on the basis of the total cumulative dose of estrogen and etiology of primary hypogonadism. Copyright © 2016 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  15. Sensitivity of disease parameters to flexible budesonide/formoterol treatment in an allergic rat model.

    PubMed

    Brange, Charlotte; Smailagic, Amir; Jansson, Anne-Helene; Middleton, Brian; Miller-Larsson, Anna; Taylor, John D; Silberstein, David S; Lal, Harbans

    2009-02-01

    Clinical studies show that flexible dosing (maintenance and symptom-driven dose adjustments) of budesonide and formoterol (BUD/FORM) improves control of asthma exacerbations as compared to fixed maintenance dosing protocols (maintenance therapy) even when the latter utilize higher BUD/FORM doses. This suggests that dose-response relationships for certain pathobiologic mechanisms in asthma shift over time. Here, we have conducted animal studies to address this issue. (1) To test in an animal asthma-like model whether it is possible to achieve the same or greater pharmacological control over bronchoconstriction and airway/lung inflammation, and with less total drug used, by flexible BUD/FORM dosing (upward adjustment of doses) in association with allergen challenges. (2) To determine whether the benefit requires adjustment of both drug components. Rats sensitized on days 0 and 7 were challenged intratracheally with ovalbumin on days 14 and 21. On days 13-21, rats were treated intratracheally with fixed maintenance or flexible BUD/FORM combinations. On day 22, rats were challenged with methacholine and lungs were harvested for analysis. A flexible BUD/FORM dosing regimen (using 3.3 times less total drug than the fixed maintenance high dose regimen), delivered the same or greater reductions of excised lung gas volume (a measure of gas trapped in lung by bronchoconstriction) and lung weight (a measure of inflammatory oedema). When either BUD or FORM alone was increased on days of challenge, the benefit of the flexible dose upward adjustment was lost. Flexible dosing of the BUD/FORM combination improves the pharmacological inhibition of allergen-induced bronchoconstriction and an inflammatory oedema in an allergic asthma-like rat model.

  16. Retrospective cross-sectional pilot study of rifaximin dosing for the prevention of recurrent hepatic encephalopathy.

    PubMed

    Lyon, Kelsey C; Likar, Eric; Martello, Jay L; Regier, Michael

    2017-09-01

    Standard treatment for hepatic encephalopathy (HE) includes medications that reduce ammonia and bacterial translocation in the gut. Rifaximin can be used off-label for the reduction of overt HE. The study purpose was to determine efficacy of traditional rifaximin dosing (400 mg three times daily) compared with newer dosing (550 mg twice daily) via readmission rates for the prevention of recurrent HE. This was a retrospective, observational, cross-sectional pilot study conducted in a tertiary medical center. A total of 226 patients 18-89 years of age with documentation of HE via ICD-9 code who started rifaximin therapy while inpatient between April 2009 and June 2014 were evaluated. Data collected included rifaximin dosing, other medications used to treat HE, duration of therapy, time to readmission, and various laboratory values. There were no differences in readmission rates at 30 days, 60 days, or 6 months between treatment groups. Additionally, there was no difference in the odds of readmission between the treatment groups (OR = 0.77, 95% CI: [0.201, 4.365], P = 0.718). Patients had a low overall probability of readmission over the observational period. Based on average wholesale price data, the cost for a 9-day supply of rifaximin for the 400-mg dosing regimen is $952.56 versus $605.16 for the 550-mg dosing regimen. The rifaximin 550-mg dosing strategy should be utilized in hospitalized patients for the prevention of recurrent HE as there was no difference in readmission rate or time to readmission between dosing groups. The 550-mg regimen had a lower acquisition cost for a 9-day duration of treatment in the studied institution. © 2017 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  17. The American brachytherapy society survey of brachytherapy practice for carcinoma of the cervix in the United States.

    PubMed

    Nag, S; Orton, C; Young, D; Erickson, B

    1999-04-01

    The purpose of this study was to survey the brachytherapy practice for cervical cancer in the United States. The Clinical Research Committee of the American Brachytherapy Society (ABS) performed a retrospective survey of individual physicians of the ABS and American Society of Therapeutic Radiologists and Oncologists regarding the details of the brachytherapy techniques they personally used in the treatment of cervical cancer patients for the year 1995. The replies (some of which may have been an estimate only) were tabulated. The scope of this survey did not allow us to verify the data by chart audits. A total of about 3500 questionnaires were mailed out; 521 responses were received. Of these responders, 206 (40%) did not perform any brachytherapy for carcinoma of the cervix in 1995. Of the other 315 responders reporting a total of 4892 patients treated in 1995, 88% used low dose rate (LDR) while 24% used high dose rate (HDR). There was a wide variation in the doses used. For LDR treatments, the median total external beam radiation therapy (EBRT) dose was 45 and 50 Gy and the LDR dose was 42 and 45 Gy for early and advanced cancers, respectively. For HDR treatments, the median EBRT dose was 48 and 50 Gy and the median HDR dose was 29 and 30 Gy for early and advanced cancers, respectively. The median dose per fraction was 6 Gy for a median of five fractions. Interstitial brachytherapy was used as a component of the treatment in 6% of the patients by 21% of responders. Very few responders treated with pulsed or medium dose rates. This retrospective survey showed the current brachytherapy practice pattern in the treatment of cervical cancer in the United States and can serve as a basis for future prospective national brachytherapy data registry. There was wide variation in the practice pattern, emphasizing the urgent need for consensus on these issues. Copyright 1999 Academic Press.

  18. Efficacy of Low-Dose Corticosteroid Therapy Versus High-Dose Corticosteroid Therapy in Bell's Palsy in Children.

    PubMed

    Arican, Pinar; Dundar, Nihal Olgac; Gencpinar, Pinar; Cavusoglu, Dilek

    2017-01-01

    Bell's palsy is the most common cause of acute peripheral facial nerve paralysis, but the optimal dose of corticosteroids in pediatric patients is still unclear. This retrospective study aimed to evaluate the efficacy of low-dose corticosteroid therapy compared with high-dose corticosteroid therapy in children with Bell's palsy. Patients were divided into 2 groups based on the dose of oral prednisolone regimen initiated. The severity of idiopathic facial nerve paralysis was graded according to the House-Brackmann Grading Scale. The patients were re-assessed in terms of recovery rate at the first, third, and sixth months of treatment. There was no significant difference in complete recovery between the 2 groups after 1, 3, and 6 months of treatment. In our study, we concluded that even at a dose of 1 mg/kg/d, oral prednisolone was highly effective in the treatment of Bell's palsy in children.

  19. Phase I study of nanoparticle albumin-bound paclitaxel, carboplatin and trastuzumab in women with human epidermal growth factor receptor 2-overexpressing breast cancer

    PubMed Central

    Tezuka, Kenji; Takashima, Tsutomu; Kashiwagi, Shinichiro; Kawajiri, Hidemi; Tokunaga, Shinya; Tei, Seika; Nishimura, Shigehiko; Yamagata, Shigehito; Noda, Satoru; Nishimori, Takeo; Mizuyama, Yoko; Sunami, Takeshi; Ikeda, Katsumi; Ogawa, Yoshinari; Onoda, Naoyoshi; Ishikawa, Tetsuro; Kudoh, Shinzoh; Takada, Minoru; Hirakawa, Kosei

    2017-01-01

    Although the concurrent use of anthracycline-containing chemotherapy and taxane with trastuzumab are considered the treatment of choice for the primary systemic therapy of human epidermal growth factor receptor 2 (HER2)-overexpressing early breast cancer, non-anthracycline regimens, such as concurrent administration of docetaxel and carboplatin with trastuzumab, exhibited similar efficacies in a previous study. In addition, tri-weekly treatment with nanoparticle albumin-bound paclitaxel (nab-paclitaxel) resulted in significantly higher response rates and a favorable safety profile compared with standard paclitaxel for metastatic breast cancer patients in another phase III study. Based on these results, a phase I study of combination therapy with nab-paclitaxel, carboplatin and trastuzumab was planned, in order to estimate its efficacy and safety for HER2-overexpressing locally advanced breast cancer. The present study was designed to determine the dose-limiting toxicity (DLT), maximum tolerated dose and recommended dose of this combination treatment in women with HER2-overexpressing locally advanced breast cancer. The starting dose of nab-paclitaxel was 220 mg/m2 (level 1), and the dose was escalated to 260 mg/m2 (level 2). Nab-paclitaxel was administered with carboplatin (area under the curve, 6 mg/ml/min) and trastuzumab tri-weekly. A total of 6 patients were enrolled. Although no DLT was observed during the first cycle, 4 patients developed grade 4 thrombocytopenia, 2 had grade 4 neutropenia and 3 exhibited a grade 4 decrease in hemoglobin levels. In the present phase I study, although no patients experienced DLTs, this regimen was associated with severe hematological toxicities and it was not well tolerated. However, considering the high efficacy and lower risk of cardiotoxicity and secondary carcinogenesis with taxane, platinum and trastuzumab combination therapy, further evaluation of another regimen including weekly administration or a more accurate dose setting should be conducted. PMID:28413662

  20. High event-free survival rate with minimum-dose-anthracycline treatment in childhood acute promyelocytic leukaemia: a nationwide prospective study by the Japanese Paediatric Leukaemia/Lymphoma Study Group.

    PubMed

    Takahashi, Hiroyuki; Watanabe, Tomoyuki; Kinoshita, Akitoshi; Yuza, Yuki; Moritake, Hiroshi; Terui, Kiminori; Iwamoto, Shotaro; Nakayama, Hideki; Shimada, Akira; Kudo, Kazuko; Taki, Tomohiko; Yabe, Miharu; Matsushita, Hiromichi; Yamashita, Yuka; Koike, Kazutoshi; Ogawa, Atsushi; Kosaka, Yoshiyuki; Tomizawa, Daisuke; Taga, Takashi; Saito, Akiko M; Horibe, Keizo; Nakahata, Tatsutoshi; Miyachi, Hayato; Tawa, Akio; Adachi, Souichi

    2016-08-01

    We evaluated the efficacy of treatment using reduced cumulative doses of anthracyclines in children with acute promyelocytic leukaemia (APL) in the Japanese Paediatric Leukaemia/Lymphoma Study Group AML-P05 study. All patients received two and three subsequent courses of induction and consolidation chemotherapy respectively, consisting of all-trans retinoic acid (ATRA), cytarabine and anthracyclines, followed by maintenance therapy with ATRA. Notably, a single administration of anthracyclines was introduced in the second induction and all consolidation therapies to minimize total doses of anthracycline. The 3-year event-free (EFS) and overall survival rates for 43 eligible children were 83·6% [95% confidence interval (CI): 68·6-91·8%] and 90·7% (95% CI: 77·1-96·4%), respectively. Although two patients died of intracranial haemorrhage or infection during induction phases, no cardiac adverse events or treatment-related deaths were observed during subsequent phases. Patients not displaying M1 marrow after the first induction therapy, or those under 5 years of age at diagnosis, showed inferior outcomes (3-year EFS rate; 33·3% (95% CI: 19·3-67·6%) and 54·6% (95% CI: 22·9-78·0%), respectively). In conclusion, a single administration of anthracycline during each consolidation phase was sufficient for treating childhood APL. In younger children, however, conventional ATRA and chemotherapy may be insufficient so that alternative therapies should be considered. © 2016 John Wiley & Sons Ltd.

  1. Basiliximab induction in kidney transplantation with donation after cardiac death donors

    PubMed Central

    YAO, XUPING; WENG, GUOBIN; WEI, JUNJUN; GAO, WENBO

    2016-01-01

    Basiliximab is a monoclonal antibody that binds to the α-chain of the interleukin (IL)-2 receptor. It is used as induction therapy in kidney transplantation. The objective of the present study was to evaluate induction therapy with single-dose basiliximab (Simulect®) in kidney transplantation with donation after cardiac death (DCD) donors. A total of 33 DCD kidney transplants were performed between December 2010 and July 2013 in patients who received single-dose basiliximab (20 mg) as induction therapy. The maintenance immunosuppression included calcineurin inhibitor (cyclosporine A or tacrolimus), mycophenolate mofetil and corticosteroids. The follow-up time was 1 year. The mean ages of the DCD donors and recipients were 29.3 and 41.1 years, respectively. Within the 1-year follow-up, the overall incidence of acute rejection was 9.1%. There were 10 cases of delayed graft function among the recipients. Mean serum creatinine values at 1 week and at 1, 3, 6, 9 and 12 months post-transplantation were 257.6, 238.2, 194.5, 159.3, 137.9 and 110.8 µmol/l, respectively, with a favorable trend to allograft function recovery over time. The 1-year patient and graft survival rates were 96.9 and 90.9%, respectively, with an infection rate of 24.2%. Increased alanine aminotransferase/aspartate transaminase levels in only 2 patients were considered to be associated with basiliximab. This experience with single-dose basiliximab for induction therapy in DCD kidney transplantation showed that favorable clinical outcomes were achieved in terms of graft survival and function within 1 year. PMID:27284346

  2. [Efficacy and side-effects of docetaxel combined with cisplatin on the treatment of local advanced esophageal cancer with concomitant radiation therapy].

    PubMed

    Zhang, Ting-rong; Zhao, Tao; Xu, Xin; Gu, Xiao-wei; Pan, Yu-kai

    2010-10-01

    To investigate the therapeutical effect and side-effect of docetaxel combined with cisplatin (DDP) on the treatment of local advanced esophageal cancer with concomitant radiation therapy. Ninety patients with LOCAL advanced esophageal squamous cell carcinoma were divided into two groups: (DDP + 5-Fu) group and (docetaxel + DDP) group. Chemotherapy was carried out every 4 weeks for a total of 4 courses. The radiation dose was 50.4 Gy/28FX. The median survival time of patients in the (DDP + 5-Fu) group was 16 months and that in (docetaxel + DDP) group was 21 months (P = 0.0278). The 3-year survival rate in the (docetaxel + DDP) group was obviously higher than that in the (DDP + 5-Fu) group (23.9% vs. 12.1%). The ORR in (docetaxel + DDP) group (84.5%) was significantly higher than that in the (DDP + 5-Fu) group (71.1%) (P = 0.025). No significant differences were observed in the incidence of side-effects in the two groups. The conventional dose chemotherapy of docetaxel + DDP with concomitant radiation therapy showed a better partial remission rate and long-term survival rate for the treatment of local advanced esophageal cancer than the traditional chemotherapy (DDP + 5-Fu) with concomitant radiation therapy and the side-effects are not increased.

  3. Kinetics of absorption and elimination of ofloxacin in humans after oral and rectal administrations.

    PubMed

    Eboka, C J; Okor, R S; Akerele, J O; Aigbavboa, S O

    1997-06-01

    Ofloxacin pharmacokinetics have been studied in four healthy subjects after a single oral or rectal dose, each of 200 mg. For the oral dose tmax was about 2 h, Cmax 1.96 +/- 0.56 micrograms/ml and AUC1-15 15.22 micrograms/ml.h. Two-phase elimination pharmacol kinetics were observed for the oral dose, t1/2 for the rapid elimination phase was 3.3 h and for the slow phase 10 h. With the rectal dose tmax was 6 h, Cmax 0.71 +/- 0.44 microgram/ml and AUC0-15 7.58 micrograms/ml.h. The relative rectal bioavailability (AUC rectal/AUC oral) was 49.8%. Elimination rate of the rectal dose was generally slow (t1/2 = 9 h), an observation attributable to the sustained-release effect of the rectal suppository base, PEG 6000. The indication is that the rectal formulation cannot be substituted totally for the oral without first increasing the rectal dose; the 200 mg suppository can however be employed as a follow-up therapy to the oral dose in certain situations.

  4. Barriers to HIV Medication Adherence as a Function of Regimen Simplification.

    PubMed

    Chen, Yiyun; Chen, Kun; Kalichman, Seth C

    2017-02-01

    Barriers to HIV medication adherence may differ by levels of dosing schedules. The current study examined adherence barriers associated with medication regimen complexity and simplification. A total of 755 people living with HIV currently taking anti-retroviral therapy were recruited from community services in Atlanta, Georgia. Participants completed audio-computer-assisted self-interviews that assessed demographic and behavioral characteristics, provided their HIV viral load obtained from their health care provider, and completed unannounced phone-based pill counts to monitor medication adherence over 1 month. Participants taking a single-tablet regimen (STR) were more likely to be adherent than those taking multi-tablets in a single-dose regimen (single-dose MTR) and those taking multi-tablets in a multi-dose regimen (multi-dose MTR), with no difference between the latter two. Regarding barriers to adherence, individuals taking STR were least likely to report scheduling issues and confusion as reasons for missing doses, but they were equally likely to report multiple lifestyle and logistical barriers to adherence. Adherence interventions may need tailoring to address barriers that are specific to dosing regimens.

  5. Work Enabling Opioid Management.

    PubMed

    Lavin, Robert A; Kalia, Nimisha; Yuspeh, Larry; Barry, Jill A; Bernacki, Edward J; Tao, Xuguang Grant

    2017-08-01

    This study describes the relationship between opioid prescribing and ability to work. The opioid prescription patterns of 4994 claimants were studied. Three groups were constructed: 1) at least 3 consecutive months prescribed (chronic opioid therapy; COT); 2) less than 3 consecutive months prescribed (acute opioid therapy; AOT); and 3) no opioids prescribed. Variables included sex, age, daily morphine equivalent dose (MED), days opioids were prescribed, temporary total days (TTDs), and medical/indemnity/total costs. The COT versus AOT claimants had higher opioid costs ($8618 vs $94), longer TTD (636.2 vs 182.3), and average MED (66.8 vs 34.9). Only 2% of the COT cohort were not released to work. Fifty-seven percent of patients in the COT category (64 of 112) were released to work while still receiving opioids. COT does not preclude ability to work when prescribing within established guidelines.

  6. Lung dose and the potential risk of death in postoperative radiation therapy for non-small cell lung cancer: A study using the method of stratified grouping.

    PubMed

    Heo, Jaesung; Noh, O Kyu; Kim, Hwan-Ik; Chun, Mison; Cho, Oyeon; Park, Rae Woong; Yoon, Dukyong; Oh, Young-Taek

    2018-04-19

    Postoperative radiation therapy may have a detrimental effect on survival in patients with non-small cell lung cancer. We investigated the association of the lung radiation dose with the risk of death in patients treated with postoperative radiation therapy. We analyzed 178 patients with non-small cell lung cancer who received postoperative radiation therapy. The mean lung dose was calculated from dose-volume data, and we categorized patients into the high and low lung dose groups using 2 different methods; (1) simple grouping using the median lung dose of all patients, and (2) stratified grouping using the median lung dose of each subgroup sharing the same confounders. We compared clinical variables, and survival between the high and low lung dose groups. In the simple grouping, there were no significant differences in survivals between the high and low lung dose groups. After stratification, the overall survival of low lung dose group was significantly longer than that of high lung dose group (5-year survival, 60.1% vs. 35.3%, p = 0.039). On multivariable analyses, the lung dose remained a significant prognostic factor for overall survival (hazard ratio, HR = 2.08, p = 0.019). The lung dose was associated with the risk of death in patients with non-small cell lung cancer having the same confounders. Further studies evaluating the risk of death according to the lung dose will be helpful to administer more precise and individualized postoperative radiation therapy. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Benefit of particle therapy in re-irradiation of head and neck patients. Results of a multicentric in silico ROCOCO trial.

    PubMed

    Eekers, Daniëlle B P; Roelofs, Erik; Jelen, Urszula; Kirk, Maura; Granzier, Marlies; Ammazzalorso, Filippo; Ahn, Peter H; Janssens, Geert O R J; Hoebers, Frank J P; Friedmann, Tobias; Solberg, Timothy; Walsh, Sean; Troost, Esther G C; Kaanders, Johannes H A M; Lambin, Philippe

    2016-12-01

    In this multicentric in silico trial we compared photon, proton, and carbon-ion radiotherapy plans for re-irradiation of patients with squamous cell carcinoma of the head and neck (HNSCC) regarding dose to tumour and doses to surrounding organs at risk (OARs). Twenty-five HNSCC patients with a second new or recurrent cancer after previous irradiation (70Gy) were included. Intensity-modulated proton therapy (IMPT) and ion therapy (IMIT) re-irradiation plans to a second subsequent dose of 70Gy were compared to photon therapy delivered with volumetric modulated arc therapy (VMAT). When comparing IMIT and IMPT to VMAT, the mean dose to all investigated 22 OARs was significantly reduced for IMIT and to 15 out of 22 OARs (68%) using IMPT. The maximum dose to 2% volume (D 2 ) of the brainstem and spinal cord were significantly reduced using IMPT and IMIT compared to VMAT. The data are available on www.cancerdata.org. In this ROCOCO in silico trial, a reduction in mean dose to OARs was achieved using particle therapy compared to photons in the re-irradiation of HNSCC. There was a dosimetric benefit favouring carbon-ions above proton therapy. These dose reductions may potentially translate into lower severe complication rates related to the re-irradiation. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  8. Use of bisphosphonate therapy for osteoporosis in childhood and adolescence.

    PubMed

    Batch, J A; Couper, J J; Rodda, C; Cowell, C T; Zacharin, M

    2003-03-01

    Congenital and acquired forms of osteoporosis in childhood and adolescence can result in morbidity from fracture and pain in childhood, and place an individual at significant risk for problems in adult life. A range of therapies exist for the prevention and treatment of osteoporosis, including optimization of daily calcium intake, adequate vitamin D status, weight-bearing exercise, treatment with sex steroids where delayed puberty is a problem and, more recently, use of bisphosphonate therapy. Intravenous pamidronate therapy (a bisphosphonate) has been shown to reduce fractures and improve bone density in children with osteogenesis imperfecta, and might prove to be of benefit in other osteoporotic conditions in childhood. However, a number of issues regarding the optimal use of bisphosphonate therapy in children and adolescents remain to be resolved, including total annual dose and frequency and duration of administration. Bisphosphonate therapy should, therefore, be used only in the context of a well-run clinical programme with specialist knowledge in the management of osteopenic disorders in childhood.

  9. Meta-analysis: the efficacy and safety of combined treatment with ARB and ACEI on diabetic nephropathy.

    PubMed

    Ren, Feifeng; Tang, Lin; Cai, Yin; Yuan, Xin; Huang, Wenhan; Luo, Lei; Zhou, Jun; Zheng, Yaning

    2015-05-01

    Angiotensin-converting enzyme inhibitors (ACEIs) and angiotensin receptor blockers (ARBs) reduce proteinuria in diabetic nephropathy (DN). Some studies have suggested that dual blockade of the renin-angiotensin system provides additive benefits in DN but others showed increased adverse events. We performed a meta-analysis to evaluate the efficacy and safety of combination therapy for DN. Studies were identified by searching MEDLINE, EMBASE, PubMed, and CNKI. All trials involved ACEI + ARB (combination therapy), and ACEI or ARB alone (monotherapy) for DN. The outcomes measured were urinary total proteinuria (UTP), urinary albumin excretion rate (UAER), serum creatinine, glomerular filtration rate (GFR), end-stage renal disease (ESRD), hyperkalemia, hypotension, and acute kidney injury (AKI). In the 32 included trials, 2596 patients received combination therapy and 3947 received monotherapy. UTP and UAER were significantly reduced by combined treatment compared with monotherapy. It was notable that low doses of combination therapy reduced UTP more than high doses. Serum creatinine, GFR, and ESRD were not significantly different between the two groups. In severe DN, the occurrence of hyperkalemia and AKI were higher with combination therapy. However, in mild DN, the prevalence of hyperkalemia and AKI were the same in both the groups. In mild DN, the occurrence of hypotension was higher with combination therapy; however, in severe DN, it was not different between the two groups. Our meta-analysis suggests that combination therapy can be used on DN with proteinuria, but should be used with caution in those with decreased renal function, especially with severe renal failure.

  10. Group therapy task training versus individual task training during inpatient stroke rehabilitation: a randomised controlled trial.

    PubMed

    Renner, Caroline Ie; Outermans, Jacqueline; Ludwig, Ricarda; Brendel, Christiane; Kwakkel, Gert; Hummelsheim, Horst

    2016-07-01

    To compare the efficacy of intensive daily applied progressive group therapy task training with equally dosed individual progressive task training on self-reported mobility for patients with moderate to severe stroke during inpatient rehabilitation. Randomized controlled clinical trial. In-patient rehabilitation center. A total of 73 subacute patients with stroke who were not able to walk without physical assistance at randomisation. Patients were allocated to group therapy task training (GT) or individual task training (IT). Both interventions were intended to improve walking competency and comprised 30 sessions of 90 minutes over six weeks. Primary outcome was the mobility domain of the Stroke Impact Scale (SIS-3.0). Secondary outcomes were the other domains of SIS-3.0, standing balance, gait speed, walking distance, stair climbing, fatigue, anxiety and depression. No adverse events were reported in either arm of the trial. There were no significant differences between groups for the SIS mobility domain at the end of the intervention (Z= -0.26, P = 0.79). No significant differences between groups were found in gait speed improvements (GT:0.38 ±0.23; IT:0.26±0.35), any other gait related parameters, or in non-physical outcomes such as depression and fatigue. Inpatient group therapy task training for patients with moderate to severe stroke is safe and equally effective as a dose-matched individual task training therapy. Group therapy task training may be delivered as an alternative to individual therapy or as valuable adjunct to increase time spent in gait-related activities. © The Author(s) 2015.

  11. Effects of Surgery and Proton Therapy on Cerebral White Matter of Craniopharyngioma Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uh, Jinsoo, E-mail: jinsoo.uh@stjude.org; Merchant, Thomas E.; Li, Yimei

    Purpose: The purpose of this study was to determine radiation dose effect on the structural integrity of cerebral white matter in craniopharyngioma patients receiving surgery and proton therapy. Methods and Materials: Fifty-one patients (2.1-19.3 years of age) with craniopharyngioma underwent surgery and proton therapy in a prospective therapeutic trial. Anatomical magnetic resonance images acquired after surgery but before proton therapy were inspected to identify white matter structures intersected by surgical corridors and catheter tracks. Longitudinal diffusion tensor imaging (DTI) was performed to measure microstructural integrity changes in cerebral white matter. Fractional anisotropy (FA) derived from DTI was statistically analyzed for 51more » atlas-based white matter structures of the brain to determine radiation dose effect. FA in surgery-affected regions in the corpus callosum was compared to that in its intact counterpart to determine whether surgical defects affect radiation dose effect. Results: Surgical defects were seen most frequently in the corpus callosum because of transcallosal resection of tumors and insertion of ventricular or cyst catheters. Longitudinal DTI data indicated reductions in FA 3 months after therapy, which was followed by a recovery in most white matter structures. A greater FA reduction was correlated with a higher radiation dose in 20 white matter structures, indicating a radiation dose effect. The average FA in the surgery-affected regions before proton therapy was smaller (P=.0001) than that in their non–surgery-affected counterparts with more intensified subsequent reduction of FA (P=.0083) after therapy, suggesting that surgery accentuated the radiation dose effect. Conclusions: DTI data suggest that mild radiation dose effects occur in patients with craniopharyngioma receiving surgery and proton therapy. Surgical defects present at the time of proton therapy appear to accentuate the radiation dose effect longitudinally. This study supports consideration of pre-existing surgical defects and their locations in proton therapy planning and studies of treatment effect.« less

  12. Proton therapy for locally advanced breast cancer: A systematic review of the literature.

    PubMed

    Kammerer, Emmanuel; Guevelou, Jennifer Le; Chaikh, Abdulhamid; Danhier, Serge; Geffrelot, Julien; Levy, Christelle; Saloux, Eric; Habrand, Jean-Louis; Thariat, Juliette

    2018-02-01

    Radiation therapy plays a major role in the management of adjuvant breast cancer with nodal involvement, with an iatrogenic increase of cardio-vascular risk. Photon therapy, even with intensity modulation, has the downsides of high mean heart dose and heterogeneous target coverage, particularly in the case of internal mammary irradiation. This systematic review of the literature aims to evaluate proton therapy in locally advanced breast cancer. PubMed was searched for original full-text articles with the following search terms: «Proton Therapy» and «Breast Cancer». On-going trials were collected using the words "Breast Cancer" and "Protons". 13 articles met the criteria: 6 with passive proton therapy (Double Scattering), 5 with Pencil Beam Scanning (PBS) and 2 with a combination of both. Proton therapy offered a better target coverage than photons, even compared with intensity modulation radiation therapy (including static or rotational IMRT or tomotherapy). With proton therapy, volumes receiving 95% of the dose were around 98%, with low volumes receiving 105% of the dose. Proton therapy often decreased mean heart dose by a factor of 2 or 3, i.e. 1 Gy with proton therapy versus 3 Gy with conventional 3D, and 6 Gy for IMRT. Lungs were better spared with proton therapy than with photon therapy. Cutaneous toxicity observed with double scattering is improved with PBS. Proton therapy reduces mean heart dose in breast cancer irradiation, probably reducing late cardio-vascular toxicity. Large clinical studies will likely confirm a clinical benefit of proton therapy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Specific immunotherapy for rhinitis and asthma with a subcutaneous hypoallergenic high-dose house dust mite extract: results of a 9-month therapy.

    PubMed

    El-Qutob, David; Moreno, Francisco; Subtil-Rodríguez, Alicia

    2016-07-01

    Effectiveness of a 9-month specific immunotherapy with a subcutaneous hypoallergenic high-dose house dust mite extract to reduce allergic symptoms as perceived by patients and physicians was assessed. An observational, retrospective, multicenter study was carried out in patients diagnosed with asthma and/or rhinitis caused by house dust mites having started specific immunotherapy with Acaroid(®). Primary end point was perceived effectiveness. A total of 409 patients were included. According to physician-completed visual analogue scale, a 58.1% clinical improvement was observed. Patient-completed visual analogue scale showed a 69.8% clinical improvement. The need for unscheduled/emergency healthcare, as an indication of poor quality of life, showed a significant reduction. Our results confirm in a real-world setting the findings from randomized clinical trials of high-dose house dust mites allergoid immunotherapy with a subcutaneous hypoallergenic high-dose house dust mite extract.

  14. Influence of daily dosage and frequency of administration of rifampicin-levofloxacin therapy on tolerance and effectiveness in 154 patients treated for prosthetic joint infections.

    PubMed

    Nguyen, S; Robineau, O; Titecat, M; Blondiaux, N; Valette, M; Loiez, C; Beltrand, E; Migaud, H; Senneville, E

    2015-08-01

    Data on the tolerance and effectiveness of rifampicin-levofloxacin combination therapy (RLCT) in patients treated for prosthetic joint infections (PJIs) according to daily dosage are lacking. A review of the clinical data from patients treated with RLCT for PJIs in a French referent center for PJIs was conducted. A total of 154 patients (75 F/79 M), with a median age of 64.1 years and median body weight of 83.1 kg, were included. The median daily dosages of rifampicin and levofloxacin were, respectively, 1,200 mg (range 300-2,100) and 750 mg (range 500-1,500), corresponding to a mean daily dose per kg of, respectively, 16.2 ± 4.3 mg/kg and 10.1 ± 3.0 mg/kg. After a mean follow-up period of 55.6 ± 27.1 months (range 24-236), 127 patients (82.5 %) were in remission. Adverse events attributable to rifampicin and levofloxacin were reported in 48 (31.2 %) and 13 (8.4 %) patients (p < 0.001), respectively. Patients who experienced rifampicin-related adverse events had been given higher rifampicin daily doses than the other patients (p = 0.04). The rifampicin daily dosage did not influence patient outcome and nor did the levofloxacin daily dosage on both tolerance and patient outcome. Our results suggest that adjusting rifampicin daily doses to the patient total body weight when combined with levofloxacin for the treatment of PJIs is associated with a poor tolerance. High daily doses of rifampicin (>600 mg) and levofloxacin (750 mg) do not improve patient outcome when compared to lower daily doses in this setting.

  15. Effect of adding piperacillin-tazobactam to automated dispensing cabinets on promptness of first-dose antibiotics in hospitalized patients.

    PubMed

    Lo, Amy; Zhu, Juanqi Nikki; Richman, Mark; Joo, Julianne; Chan, Patrick

    2014-10-01

    Significant improvements in order-to-administration times for critical first doses of i.v. antibiotic therapy through the use of automated dispensing cabinets (ADCs) are reported. In a retrospective pre-post analysis conducted at a large academic medical center, pharmacy and medical records were reviewed to evaluate average times to administration of first doses of i.v. piperacillin-tazobactam therapy during designated periods before and after the addition of selected i.v. antibiotics to ADCs on patient care units. Inpatients who received a specified i.v. piperacillin-tazobactam formulation were included in the analysis. The primary endpoint was the total time from prescribing to administration; the impact of ADC use on other time intervals (e.g., from scanning of orders to administration, from pharmacist verification and release of orders to administration) was also evaluated. A total of 121 subjects were included in the preimplementation (n = 65) and postimplementation (n = 56) samples. There was a significant 1.7-hour reduction in the mean ± S.D. order-to-administration time (from 4.5 ± 4.1 to 2.9 ± 2.5 hours, p = 0.009) for piperacillin-tazobactam first doses with the use of ADCs. Subgroup analyses showed significant reductions in the mean ± S.D. scan-to-administration time (from 3.3 ± 3.4 to 1.7 ± 1.5 hours, p = 0.001) and release-to-administration time (from 2.4 ± 2.4 to 1.4 ± 1.5 hours, p = 0.034). The addition of a piperacillin-tazobactam product and other commonly used i.v. antibiotics to ADCs was associated with a significantly reduced order-to-administration time for piperacillin-tazobactam first doses. This change was accounted for by a significant reduction in the time between order entry and drug administration. Copyright © 2014 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  16. Phase 1/2 Study of the CD56-Targeting Antibody-Drug Conjugate Lorvotuzumab Mertansine (IMGN901) in Combination With Carboplatin/Etoposide in Small-Cell Lung Cancer Patients With Extensive-Stage Disease.

    PubMed

    Socinski, Mark A; Kaye, Frederic J; Spigel, David R; Kudrik, Fred J; Ponce, Santiago; Ellis, Peter M; Majem, Margarita; Lorigan, Paul; Gandhi, Leena; Gutierrez, Martin E; Nepert, Dale; Corral, Jesus; Ares, Luis Paz

    2017-01-01

    This trial assessed the safety and efficacy of LM in combination with carboplatin/etoposide therapy compared to carboplatin/etoposide treatment alone in patients with previously untreated extensive-disease small-cell lung cancer (ED-SCLC). A run-in phase 1 stage was used to determine the recommended phase 2 dose and characterize the dose-limiting toxicities of LM in combination with carboplatin/etoposide followed by LM alone in patients with CD56-positive solid tumors. In phase 2, chemotherapy-naive ED-SCLC patients were randomized 2:1 to carboplatin AUC (area under the plasma concentration vs. time curve) of 5 day 1 + etoposide 100 mg/m 2 days 1 to 3 plus LM (arm 1) or alone (arm 2). In the phase 1 study (n = 33), a dose of LM at 112 mg/m 2 with carboplatin/etoposide was identified as the recommended phase 2 dose. However, because of an increased incidence of peripheral neuropathy events during early phase 2, this dose was reduced to 90 mg/m 2 . In phase 2, a total of 94 and 47 evaluable patients were assigned to arms 1 and 2, respectively. No difference in median progression-free survival was observed between arms 1 and 2 (6.2 vs. 6.7 months). The most common treatment-emergent adverse event leading to discontinuation was peripheral neuropathy (29%). A total of 21 patients had a treatment-emergent adverse event leading to death (18 in arm 1 and 3 in arm 2); for 10 individuals, this was an infection (pneumonia or sepsis) deemed to be related to the study drug. The combination of LM plus carboplatin/etoposide did not improve efficacy over standard carboplatin/etoposide doublet therapy in ED-SCLC patients and showed increased toxicity, including a higher incidence of serious infections with fatal outcomes. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  17. Effect of Laser Therapy on Chronic Osteoarthritis of the Knee in Older Subjects

    PubMed Central

    Youssef, Enas Fawzey; Muaidi, Qassim Ibrahim; Shanb, Alsayed Abdelhameed

    2016-01-01

    Introduction: Osteoarthritis (OA) is a common degenerative joint disease particularly in older subjects. It is usually associated with pain, restricted range of motion, muscle weakness, difficulties in daily living activities and impaired quality of life. To determine the effects of adding two different intensities of low-level laser therapy (LLLT) to exercise training program on pain severity, joint stiffness, physical function, isometric muscle strength, range of motion of the knee, and quality of life in older subjects with knee OA. Methods: Patients were randomly assigned into three groups. They received 16 sessions, 2 sessions/week for 8 weeks. Group-I: 18 patients were treated with a laser dose of 6 J/cm2 with a total dose of 48 J. Group-II: 18 patients were treated with a laser dose of 3 J/cm2 with a total dose of 27 J. Group-III: 15 patients were treated with laser without emission as a placebo. All patients received same exercise training program including stretching and strengthening exercises. Patients were evaluated before and after intervention by visual analogue scale (VAS), the Western Ontario and McMaster Universities Osteoarthritis (WOMAC) index for quality of life, handheld dynamometer and universal goniometer. Results: T test revealed that there was a significant reduction in VAS and pain intensity, an increase in isometric muscle strength and range of motion of the knee as well as increase in physical functional ability in three treatment groups. Also analysis of variance (ANOVA) proved significant differences among them and the post hoc tests (LSD) test showed the best improvements for patients of the first group. Conclusion: It can be concluded that addition of LLLT to exercise training program is more effective than exercise training alone in the treatment of older patients with chronic knee OA and the rate of improvement may be dose dependent, as with 6 J/cm2 or 3 J/cm2. PMID:27330707

  18. Monitoring tumor response of prostate cancer to radiation therapy by multi-parametric 1H and hyperpolarized 13C magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Zhang, Vickie Yi

    Radiation therapy is one of the most common curative therapies for patients with localized prostate cancer, but despite excellent success rates, a significant number of patients suffer post- treatment cancer recurrence. The accurate characterization of early tumor response remains a major challenge for the clinical management of these patients. Multi-parametric MRI/1H MR spectroscopy imaging (MRSI) has been shown to increase the diagnostic performance in evaluating the effectiveness of radiation therapy. 1H MRSI can detect altered metabolic profiles in cancerous tissue. In this project, the concentrations of prostate metabolites from snap-frozen biopsies of recurrent cancer after failed radiation therapy were correlated with histopathological findings to identify quantitative biomarkers that predict for residual aggressive versus indolent cancer. The total choline to creatine ratio was significantly higher in recurrent aggressive versus indolent cancer, suggesting that use of a higher threshold tCho/Cr ratio in future in vivo 1H MRSI studies could improve the selection and therapeutic planning for patients after failed radiation therapy. Varying radiation doses may cause a diverse effect on prostate cancer micro-environment and metabolism, which could hold the key to improving treatment protocols for individual patients. The recent development and clinical translation of hyperpolarized 13C MRI have provided the ability to monitor both changes in the tumor micro-environment and its metabolism using a multi-probe approach, [1-13C]pyruvate and 13C urea, combined with 1H Multi-parametric MRI. In this thesis, hyperpolarized 13C MRI, 1H dynamic contrast enhancement, and diffusion weighted imaging were used to identify early radiation dose response in a transgenic prostate cancer model. Hyperpolarized pyruvate to lactate metabolism significantly decreased in a dose dependent fashion by 1 day after radiation therapy, prior to any changes observed using 1H DCE and diffusion weighted imaging. Hyperpolarized 13C urea and 1H DCE both show increase in perfusion/permeability by 4 days post-radiation. In tumor region treated with high dose radiation, ADC values significantly increased post-radiation, suggesting a decrease in cellular density. These dose dependent changes can be used as markers of early tumor response to the impact of increasing doses of radiation therapy. In addition, a spectral-spatial pulse sequence was developed for the 14T to dynamically observe kinetic information in a transgenic prostate cancer model before and after radiation therapy. A novel modeling approach was proposed to parameterize perfusion in the kinetic modeling of pyruvate to lactate conversion for better characterization of pyruvate metabolism. Unlike single time point HP 13C urea imaging, quantitative pharmacokinetic parameters such as blood flow and extracellular extravascular volume fraction can be extracted from dynamic acquisitions. Blood flow measured by hyperpolarized 13C urea was highly correlated with Ktrans measured by 1H DCE, suggesting hyperpolarized urea might be able to provide similar information as 1H DCE. The results of this thesis show that Multi-parametric MRI, including functional MRI, 1H MRSI, and hyperpolarized 13C, holds great potential for evaluating early tumor response to radiation therapy of prostate cancer. The findings of this thesis will be useful in designing future studies for using combined Multi-parametric 1H and hyperpolarized 13C MRI to improve planning and assessing radiation therapy in individual prostate cancer patients.

  19. Impact of computerized order entry and pre-mixed dialysis solutions for continuous veno-venous hemodiafiltration on selection of therapy for acute renal failure.

    PubMed

    Saadulla, Lawand; Reeves, W Brian; Irey, Brittany; Ghahramani, Nasrollah

    2012-02-01

    To investigate the impacts of availability of pre-mixed solutions and computerized order entry on nephrologists' choice of the initial mode of renal replacement therapy in acute renal failure. We studied 898 patients with acute renal failure in 3 consecutive eras: era 1 (custom-mixed solution; n = 309), era 2 (pre-mixed commercial solution; n = 324), and era 3 (post-computerized order entry; n = 265). The proportion of patients treated with renal replacement therapy and the time from consult to initiation of continuous renal replacement therapy was similar in the 3 eras. Following introduction of the pre-mixed solution, the proportion of patients treated with continuous renal replacement therapy increased (20% vs. 33%; p < 0.05), it was initiated at a lower serum creatinine (353 ± 123 μmol/L vs. 300 ± 80 μmol/L; p < 0.05) and in older patients (53 ± 12 vs. 61 ± 14 years; p < 0.05). There was a progressive increase in the use of continuous veno-venous hemodialysis (18% vs. 79% vs. 100%; p < 0.05) and in the total prescribed flow rate (1,382 ± 546 vs. 2,324 ± 737 vs. 2,900 ± 305 mL/hr 3; p < 0.05). There was no significant impact on mortality. The availability of a pre-mixed solution increases the likelihood of initiating continuous renal replacement therapy in acute renal failure, initiating it at a lower creatinine and for older patients, use of continuous veno-venous hemodialysis and higher prescribed continuous renal replacement therapy dose. Computerized order entry implementation is associated with an additional increase in the use of continuous veno-venous hemodialysis, higher total prescribed dialysis dose, and use of CRRT among an increasing number of patients not on mechanical ventilation. The effect of these changes on patient survival is not significant.

  20. Long-Term Outcomes Among Patients Who Achieve Complete or Near-Complete Responses After the Induction Phase of Bladder-Preserving Combined-Modality Therapy for Muscle-Invasive Bladder Cancer: A Pooled Analysis of NRG Oncology/RTOG 9906 and 0233

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitin, Timur, E-mail: mitin@ohsu.edu; George, Asha; Zietman, Anthony L.

    Purpose: To investigate the differences in outcomes among patients with muscle-invasive bladder cancer on NRG Oncology Radiation Therapy Oncology Group protocols 9906 and 0233 who achieved complete response and near-complete response after induction chemoradiation and then completed bladder-preserving therapy with chemoradiation therapy (chemo-RT) to full dose (60-64 Gy). Patients and Methods: A pooled analysis was performed on 119 eligible patients with muscle-invasive bladder cancer enrolled on NRG Oncology Radiation Therapy Oncology Group trials 9906 and 0233, who were classified as having a complete (T0) or near-complete (Ta or Tis) response after induction chemo-RT and completed consolidation with a total RT dose ofmore » at least 60 Gy. Bladder recurrence, salvage cystectomy rates, and disease-specific survival were estimated by the cumulative incidence method and bladder-intact and overall survivals by the Kaplan-Meier method. Results: Among the 119 eligible patients, 101 (85%) achieved T0, and 18 (15%) achieved Ta or Tis after induction chemo-RT and proceeded to consolidation. After a median follow-up of 5.9 years, 36 of 101 T0 patients (36%) versus 5 of 18 Ta or Tis patients (28%) experienced bladder recurrence (P=.52). Thirteen patients among complete responders eventually required late salvage cystectomy for tumor recurrence, compared with 1 patient among near-complete responders (P=.63). Disease-specific, bladder-intact, and overall survivals were not significantly different between T0 and Ta/Tis cases. Conclusions: The bladder recurrence and salvage cystectomy rates of the complete and the near-complete responders were similar. Therefore it is reasonable to recommend that patients with Ta or Tis after induction chemo-RT continue with bladder-sparing therapy with consolidation chemo-RT to full dose (60-64 Gy).« less

  1. SU-E-T-435: Development and Commissioning of a Complete System for In-Vivo Dosimetry and Range Verification in Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samuel, D; Testa, M; Park, Y

    Purpose: In-vivo dose and beam range verification in proton therapy could play significant roles in proton treatment validation and improvements. Invivo beam range verification, in particular, could enable new treatment techniques one of which, for example, could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. We have developed and commissioned an integrated system with hardware, software and workflow protocols, to provide a complete solution, simultaneously for both in-vivo dosimetry and range verification for proton therapy. Methods: The system uses a matrix of diodes, up to 12 in total, but separablemore » into three groups for flexibility in application. A special amplifier was developed to capture extremely small signals from very low proton beam current. The software was developed within iMagX, a general platform for image processing in radiation therapy applications. The range determination exploits the inherent relationship between the internal range modulation clock of the proton therapy system and the radiological depth at the point of measurement. The commissioning of the system, for in-vivo dosimetry and for range verification was separately conducted using anthropomorphic phantom. EBT films and TLDs were used for dose comparisons and range scan of the beam distal fall-off was used as ground truth for range verification. Results: For in-vivo dose measurement, the results were in agreement with TLD and EBT films and were within 3% from treatment planning calculations. For range verification, a precision of 0.5mm is achieved in homogeneous phantoms, and a precision of 2mm for anthropomorphic pelvic phantom, except at points with significant range mixing. Conclusion: We completed the commissioning of our system for in-vivo dosimetry and range verification in proton therapy. The results suggest that the system is ready for clinical trials on patient.« less

  2. Stereotactic Ablative Body Radiation Therapy for Primary Kidney Cancer: A 3-Dimensional Conformal Technique Associated With Low Rates of Early Toxicity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pham, Daniel, E-mail: daniel.pham@petermac.org; Department of Medical Imaging and Radiation Sciences, Monash University, Melbourne, Victoria; Thompson, Ann

    Purpose: To describe our 3-dimensional conformal planning approaches and report early toxicities with stereotactic body radiation therapy for the management of primary renal cell carcinoma. Methods and Materials: This is an analysis of a phase 1 trial of stereotactic body radiation therapy for primary inoperable renal cell carcinoma. A dose of 42 Gy/3 fractions was prescribed to targets ≥5 cm, whereas for <5 cm 26 Gy/1 fraction was used. All patients underwent a planning 4-dimensional CT to generate a planning target volume (PTV) from a 5-mm isotropic expansion of the internal target volume. Planning required a minimum of 8 fields prescribing to the minimummore » isodose surrounding the PTV. Intermediate dose spillage at 50% of the prescription dose (R50%) was measured to describe the dose gradient. Early toxicity (<6 months) was scored using the Common Terminology Criteria for Adverse Events (v4.0). Results: From July 2012 to August 2013 a total of 20 patients (median age, 77 years) were recruited into a prospective clinical trial. Eleven patients underwent fractionated treatment and 9 patients a single fraction. For PTV targets <100 cm{sup 3} the median number of beams used was 8 (2 noncoplanar) to achieve an average R50% of 3.7. For PTV targets >100 cm{sup 3} the median beam number used was 10 (4 noncoplanar) for an average R50% value of 4.3. The R50% was inversely proportional to decreasing PTV volume (r=−0.62, P=.003) and increasing total beams used (r=−0.51, P=.022). Twelve of 20 patients (60%) suffered grade ≤2 early toxicity, whereas 8 of 20 patients (40%) were asymptomatic. Nausea, chest wall pain, and fatigue were the most common toxicities reported. Conclusion: A 3-dimensional conformal planning technique of 8-10 beams can be used to deliver highly tolerable stereotactic ablation to primary kidney targets with minimal early toxicities. Ongoing follow-up is currently in place to assess long-term toxicities and cancer control.« less

  3. Late Consequential Surgical Bed Soft Tissue Necrosis in Advanced Oropharyngeal Squamous Cell Carcinomas Treated With Transoral Robotic Surgery and Postoperative Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lukens, J. Nicholas; Lin, Alexander, E-mail: alexander.lin@uphs.upenn.edu; Gamerman, Victoria

    Purpose: A subset of patients with oropharyngeal squamous cell carcinoma (OP-SCC) managed with transoral robotic surgery (TORS) and postoperative radiation therapy (PORT) developed soft tissue necrosis (STN) in the surgical bed months after completion of PORT. We investigated the frequency and risk factors. Materials and Methods: This retrospective analysis included 170 consecutive OP-SCC patients treated with TORS and PORT between 2006 and 2012, with >6 months' of follow-up. STN was defined as ulceration of the surgical bed >6 weeks after completion of PORT, requiring opioids, biopsy, or hyperbaric oxygen therapy. Results: A total of 47 of 170 patients (28%) hadmore » a diagnosis of STN. Tonsillar patients were more susceptible than base-of-tongue (BOT) patients, 39% (41 of 104) versus 9% (6 of 66), respectively. For patients with STN, median tumor size was 3.0 cm (range 1.0-5.6 cm), and depth of resection was 2.2 cm (range 1.0-5.1 cm). Median radiation dose and dose of fraction to the surgical bed were 6600 cGy and 220 cGy, respectively. Thirty-one patients (66%) received concurrent chemotherapy. Median time to STN was 2.5 months after PORT. All patients had resolution of STN after a median of 3.7 months. Multivariate analysis identified tonsillar primary (odds ratio [OR] 4.73, P=.01), depth of resection (OR 3.12, P=.001), total radiation dose to the resection bed (OR 1.51 per Gy, P<.01), and grade 3 acute mucositis (OR 3.47, P=.02) as risk factors for STN. Beginning May 2011, after implementing aggressive avoidance of delivering >2 Gy/day to the resection bed mucosa, only 8% (2 of 26 patients) experienced STN (all grade 2). Conclusions: A subset of OP-SCC patients treated with TORS and PORT are at risk for developing late consequential surgical bed STN. Risk factors include tonsillar location, depth of resection, radiation dose to the surgical bed, and severe mucositis. STN risk is significantly decreased with carefully avoiding a radiation dosage of >2 Gy/day to the surgical bed.« less

  4. Dyshidrotic eczema associated with the use of IVIg

    PubMed Central

    Kotan, Dilcan; Erdem, Teoman; Acar, Bilgehan Atilgan; Boluk, Ayhan

    2013-01-01

    Intravenous immunoglobulin (IVIg) treatment is highly effective for autoimmune diseases including myasthenia gravis. Recovery is observed at approximately. 75% of myasthenia gravis patients through IVIg treatment. As a result of many clinical studies, the recommended dose is determined as 0.4 g/kg for 5 days (maximum total dose at 2 g/kg body weight). If an additional immunomodulatory treatment is not administered, IVIg maintenance treatment is needed mostly. However, some side effects may inhibit long-term treatment. For this reason, it is important to know the effect profile well and when the treatment should be discontinued. A female myasthenia gravis patient case is presented here, where dyshidrotic eczema has occurred after the second dose of  intravenous Ig medication and whose treatment is despite further IVIg therapy. PMID:23417935

  5. TU-CD-304-01: FEATURED PRESENTATION and BEST IN PHYSICS (THERAPY): Trajectory Modulated Arc Therapy: Development of Novel Arc Delivery Techniques Integrating Dynamic Table Motion for Extended Volume Treatments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chin, E; Hoppe, R; Million, L

    2015-06-15

    Purpose: Integration of coordinated robotic table motion with inversely-planned arc delivery has the potential to resolve table-top delivery limitations of large-field treatments such as Total Body Irradiation (TBI), Total Lymphoid Irradiation (TLI), and Cranial-Spinal Irradiation (CSI). We formulate the foundation for Trajectory Modulated Arc Therapy (TMAT), and using Varian Developer Mode capabilities, experimentally investigate its practical implementation for such techniques. Methods: A MATLAB algorithm was developed for inverse planning optimization of the table motion, MLC positions, and gantry motion under extended-SSD geometry. To maximize the effective field size, delivery trajectories for TMAT TBI were formed with the table rotated atmore » 270° IEC and dropped vertically to 152.5cm SSD. Preliminary testing of algorithm parameters was done through retrospective planning analysis. Robotic delivery was programmed using custom XML scripting on the TrueBeam Developer Mode platform. Final dose was calculated using the Eclipse AAA algorithm. Initial verification of delivery accuracy was measured using OSLDs on a solid water phantom of varying thickness. Results: A comparison of DVH curves demonstrated that dynamic couch motion irradiation was sufficiently approximated by static control points spaced in intervals of less than 2cm. Optimized MLC motion decreased the average lung dose to 68.5% of the prescription dose. The programmed irradiation integrating coordinated table motion was deliverable on a TrueBeam STx linac in 6.7 min. With the couch translating under an open 10cmx20cm field angled at 10°, OSLD measurements along the midline of a solid water phantom at depths of 3, 5, and 9cm were within 3% of the TPS AAA algorithm with an average deviation of 1.2%. Conclusion: A treatment planning and delivery system for Trajectory Modulated Arc Therapy of extended volumes has been established and experimentally demonstrated for TBI. Extension to other treatment techniques such as TLI and CSI is readily achievable through the developed platform. Grant Funding by Varian Medical Systems.« less

  6. The effect of ezetimibe-statin combination on steroid hormone production in men with coronary artery disease and low cholesterol levels.

    PubMed

    Krysiak, Robert; Kowalska, Beata; Żmuda, Witold; Okopień, Bogusław

    2015-04-01

    Aggressive statin treatment was found to slightly reduce testosterone production. The aim of this study was to compare the effects of ezetimibe-statin combination and high-dose statin therapy on testicular and adrenal cortex function in men with LDL cholesterol levels below 70 mg/dL. The study included 26 adult men with coronary artery disease. Twelve of these patients did not tolerate high-dose statin therapy and were treated with lower doses of a statin plus ezetimibe. Fourteen patients tolerating high-dose simvastatin or rosuvastatin treatment continued high-dose statin therapy throughout the study period. Plasma lipids, glucose homeostasis markers and plasma levels of testosterone, cortisol, dehydroepiandrosterone sulphate, sex hormone-binding globulin, gonadotropins and ACTH, as well as urine free cortisol were assessed at baseline and after 16 weeks of treatment. Replacing high-dose statin therapy with ezetimibe/statin combination therapy reduced plasma levels of LH by 32% (p=0.043), as well as increased plasma levels of testosterone by 20% (p=0.038). Ezetimibe/statin combination did not induce any significant changes in plasma levels or urine excretion of the remaining hormones. At the end of the study, plasma LH levels were higher, while plasma testosterone levels were lower in patients receiving the combination therapy than in those treated only with high-dose statin. Our results indicate that ezetimibe combined with moderate statin dose exerts a less pronounced effect on testicular function in comparison with high-dose statin therapy. Copyright © 2014 Institute of Pharmacology, Polish Academy of Sciences. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  7. Pharmacokinetics and Pharmacodynamics of Piperacillin-Tazobactam in 42 Patients Treated with Concomitant CRRT

    PubMed Central

    Bauer, Seth R.; Salem, Charbel; Connor, Michael J.; Groszek, Joseph; Taylor, Maria E.; Wei, Peilin; Tolwani, Ashita J.

    2012-01-01

    Summary Background and objectives Current recommendations for piperacillin-tazobactam dosing in patients receiving continuous renal replacement therapy originate from studies with relatively few patients and lower continuous renal replacement therapy doses than commonly used today. This study measured the pharmacokinetic and pharmacodynamic characteristics of piperacillin-tazobactam in patients treated with continuous renal replacement therapy using contemporary equipment and prescriptions. Design, setting, participants, & measurements A multicenter prospective observational study in the intensive care units of two academic medical centers was performed, enrolling patients with AKI or ESRD receiving piperacillin-tazobactam while being treated with continuous renal replacement therapy. Pregnant women, children, and patients with end stage liver disease were excluded from enrollment. Plasma and continuous renal replacement therapy effluent samples were analyzed for piperacillin and tazobactam levels using HPLC. Pharmacokinetic and pharmacodynamic parameters were calculated using standard equations. Multivariate analyses were used to examine the association of patient and continuous renal replacement therapy characteristics with piperacillin pharmacokinetic parameters. Results Forty-two of fifty-five subjects enrolled had complete sampling. Volume of distribution (median=0.38 L/kg, intraquartile range=0.20 L/kg) and elimination rate constants (median=0.104 h−1, intraquartile range=0.052 h−1) were highly variable, and clinical parameters could explain only a small fraction of the large variability in pharmacokinetic parameters. Probability of target attainment for piperacillin was 83% for total drug but only 77% when the unbound fraction was considered. Conclusions There is significant patient to patient variability in pharmacokinetic/pharmacodynamic parameters in patients receiving continuous renal replacement therapy. Many patients did not achieve pharmacodynamic targets, suggesting that therapeutic drug monitoring might optimize therapy. PMID:22282479

  8. SU-E-T-193: FMEA Severity Scores - Do We Really Know?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khan, A; Robertson, JD; Narra, V

    2014-06-01

    Purpose: Mycosis fungoides is a common form of cutaneous T-cell lymphoma which generally affects the skin. A typical course of treatment may include fractionated total skin electron beam therapy. Given the difficulties in uniformly irradiating some regions of the body and the need for frequent visits within the context of a fractionated protocol, this study investigated the feasibility of delivering the dose using form-fitting cloth which contained phosphorous-32 as a source for beta particle irradiation. Methods: A piece of fabric (0.97 g) consisting of a blend of spandex and flame retardant material impregnated with phosphorus-31 (2000 ppm) was bombarded withmore » neutrons to produce phosphorus-32. The cloth was then laid flat and a stack of radiochromic film placed on top. Sheets of film and tissue equivalent plastic were layered to form a stack measuring a total of 1 cm thickness and remained sandwiched for 77.3 hr. Results: The initial activity of the activated cloth was 44 μCi of P-32. The absorbed dose was uniform within planes parallel to the cloth and exponentially dependent on depth, delivering 560cGy at 0.3mm and falling to 20cGy at 3mm. Conclusion: The total dose prescribed for a typical course of TSET for mycosis fungoides is 36Gy delivered over 9 weeks and is expected to treat to at least 5mm depth. Therefore, the P-32 impregnated cloth may not be clinically indicated to treat this disease given the unfavorable depth-dose characteristics. However, a major advantage of using form-fitting cloth is the uniformity with which the dose could be delivered over the skin in areas which are not flat. Increasing the distance between cloth and skin could improve the depth-dose characteristics.« less

  9. Highly effective reduced toxicity dose-intensive pilot protocol for non-metastatic limb osteogenic sarcoma (SCOS 89).

    PubMed

    Shkalim-Zemer, Vered; Ash, Shifra; Toledano, Helen; Kollender, Yehuda; Issakov, Josephine; Yaniv, Isaac; Cohen, Ian J

    2015-11-01

    Aggressive chemotherapy protocols for non-metastatic limb osteosarcoma have improved histological response without affecting prognosis. This study evaluated the toxicity and outcome of a dose-intensive, high-dose 3- to 5-drug pilot protocol, SCOS 89. The cohort included 26 patients (14 male; ages 6.5-22 years) with non-metastatic limb osteosarcoma treated at a tertiary pediatric medical center between 1989 and 2013. Preoperatively, patients received two courses of once-weekly pulses of high-dose methotrexate (12-30 g/m(2)) for 2 weeks; doxorubicin (90 mg/m(2)) with dexrazoxane, combined with cisplatin (200 mg/m(2)), was added in week 3. Following methotrexate, 760 mg/m(2) of folinic acid was administered. Postoperative chemotherapy was continued to a total of 14 courses of methotrexate, doxorubicin (up to a total dose of 360 mg/m(2)), and cisplatin (up to a total dose of 560 mg/m(2)). If toxicity occurred or <90 % tumor necrosis, ifosfamide (12 g/m(2)) plus etoposide (500 mg/m(2)) was substituted for doxorubicin, cisplatin, or methotrexate. Toxicity and death rates were calculated. All patients underwent definitive limb salvage surgery. Six patients died of infection, recurrent disease, or secondary malignancy. Median follow-up was 100 months (range 2-290). Event-free and overall survival rates, respectively, were 88 and 96 % at 2 years, 80 and 87.6 % at 5 years, 80 and 78 % at 10 years. Eleven patients required ifosfamide/etoposide substitution. One patient had a transient decreased left ventricular ejection fraction. Two patients developed acute nephrotoxicity during therapy, but no neurotoxicity. Seven patients had hearing impairment. The SCOS 89 yields a high event-free survival rate with reduced nephro-/neuro-/cardiotoxicity in patients with non-metastatic limb osteosarcoma.

  10. Association of Medicare's Bundled Payment Reform With Changes in Use of Vitamin D Among Patients Receiving Maintenance Hemodialysis: An Interrupted Time-Series Analysis.

    PubMed

    Spoendlin, Julia; Schneeweiss, Sebastian; Tsacogianis, Theodore; Paik, Julie M; Fischer, Michael A; Kim, Seoyoung C; Desai, Rishi J

    2018-06-08

    Medicare's 2011 prospective payment system (PPS) was introduced to curb overuse of separately billable injectable drugs. After epoietin, intravenous (IV) vitamin D analogues are the biggest drug cost drivers in hemodialysis (HD) patients, but the association between PPS introduction and vitamin D therapy has been scarcely investigated. Interrupted time-series analyses. Adult US HD patients represented in the US Renal Data System between 2008 and 2013. PPS implementation. The cumulative dose of IV vitamin D analogues (paricalcitol equivalents) per patient per calendar quarter in prevalent HD patients. The average starting dose of IV vitamin D analogues and quarterly rates of new vitamin D use (initiations/100 person-months) in incident HD patients within 90 days of beginning HD therapy. Segmented linear regression models of the immediate change and slope change over time of vitamin D use after PPS implementation. Among 359,600 prevalent HD patients, IV vitamin D analogues accounted for 99% of the total use, and this trend was unchanged over time. PPS resulted in an immediate 7% decline in the average dose of IV vitamin D analogues (average baseline dose = 186.5 μg per quarter; immediate change = -13.5 μg [P < 0.001]; slope change = 0.43 per quarter [P = 0.3]) and in the starting dose of IV vitamin D analogues in incident HD patients (average baseline starting dose = 5.22 μg; immediate change = -0.40 μg [P < 0.001]; slope change = -0.03 per quarter [P = 0.03]). The baseline rate of vitamin D therapy initiation among 99,970 incident HD patients was 44.9/100 person-months and decreased over time, even before PPS implementation (pre-PPS β = -0.46/100 person-months [P < 0.001]; slope change = -0.19/100 person-months [P = 0.2]). PPS implementation was associated with an immediate change in initiation levels (by -4.5/100 person-months; P < 0.001). Incident HD patients were restricted to those 65 years or older. PPS implementation was associated with a 7% reduction in the average dose and starting dose of IV vitamin D analogues and a 10% reduction in the rate of vitamin D therapy initiation. Copyright © 2018 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  11. Iodine kinetics and dosimetry in the salivary glands during repeated courses of radioiodine therapy for thyroid cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, B.; Huang, R.; Kuang, A.

    2011-10-15

    Purpose: The present study was conducted to investigate salivary iodine kinetics and dosimetry during repeated courses of radioiodine ({sup 131}I) therapy for differentiated thyroid cancer (DTC). Such data could provide a better understanding of the mechanisms of {sup 131}I induced salivary toxicity and help to develop appropriate methods to reduce this injury. Methods: Seventy-eight consecutive DTC patients (mean age 45 {+-} 17 years, 60%, female) undergoing {sup 131}I therapy for remnant ablation or metastatic tumors were prospectively recruited. Planar quantitative scintigraphy of head-neck images was serially acquired after administration of 2.9-7.4 GBq of {sup 131}I to assess kinetics in themore » salivary glands of patients. Salivary absorbed doses were calculated based on the schema of Medical Internal Radiation Dosimetry. Results: The maximum uptakes in percentage of administered {sup 131}I activity per kilogram of gland tissue (%/kg) were 12.9% {+-} 6.5%/kg (range, 0.4%-37.3%/kg) and 12.3% {+-} 6.2%/kg (range, 0.4%-35.1%/kg) for the parotid and submandibular glands, respectively. Statistically significant correlations of maximum uptake versus cumulative activity (r = -0.74, P < 0.01, for the parotid glands; r = -0.71, P < 0.01, for the submandibular glands) and treatment cycle (P < 0.001, for both gland types) were found. The effective half-lives of {sup 131}I in the parotid and submandibular glands were 9.3 {+-} 3.5 h (range, 1.5-19.8 h) and 8.6 {+-} 3.2 h (range, 0.8-18.0 h), respectively. A statistically significant correlation was observed between effective half-life with cumulative activity (r = 0.37, P < 0.01) and treatment cycle (P = 0.03) only for the parotid glands. The calculated absorbed doses were 0.20 {+-} 0.10 mGy/MBq (range, 0.01-0.92 mGy/MBq) and 0.25 {+-} 0.09 mGy/MBq (range, 0.01-1.52 mGy/MBq) for the parotid and submandibular glands, respectively. The photon contribution to the salivary absorbed dose was minimal in relation to the beta dose contribution. Photon-absorbed dose fractions of total absorbed dose were 4.9% {+-} 1.3% (range, 1.1%-8.7%) and 3.7% {+-} 2.5% (range, 0.8%-7.9%) for the parotid and submandibular glands, respectively. Conclusions: The iodine uptake of salivary glands is continuously reduced during the courses of therapy. The phenomenon of hyper-radiosensitivity may to some extent account for the occurrence of salivary gland hypofunction at very low radiation doses with low dose rates in {sup 131}I therapy. On the other hand, failure to incorporate a nonuniform and preferential uptake by salivary gland ductal cells may result in underestimating the actual dose for the critical tissue. Other methods, including {sup 124}I voxel-based dosimetry, are warranted to further investigate the {sup 131}I-induced salivary gland toxicity.« less

  12. Observation of combined/optimized therapy of Lamivudine and Adefovir Dipivoxyl for hepatitis B-induced decompensated cirrhosis with baseline HBV DNA>1,000 IU/mL.

    PubMed

    Zhang, D; Zhao, G; Li, L; Li, Z

    2017-01-01

    This study aimed to observe and compare the efficacy and safety of the combined therapy and two different optimized therapies of lamivudine (LAM) and adefovir dipivoxil (ADV), as well as entecavir (ETV) monotherapy in patients with hepatitis B-induced decompensated cirrhosis. Method : A total of 127 patients with decompensated cirrhosis were divided into four groups, and each group received different doses of regimens: initial combination of LAM and ADV, ADV add-on therapies with previous 12-week LAM, ADV add-on therapies with previous 24-week LAM, and ETV monotherapy. At the end of the treatment, the level of alanine amino-transferase (ALT), albumin (ALB) and total bilirubin (TBIL) in the combination therapy group and 12-week optimized therapy group were significantly improved. For the 24-week optimized therapy group, only ALT levels revealed a significant improvement. There were no obvious differences in the normalization rate of ALT, negative conversion rate of HBV DNA and HBeAg, as well as improvement in Child-Pugh scores among the combination therapy group, 12-week optimized therapy group, and ETV monotherapy group. However, the difference among these three groups and the 24-week optimized therapy group were significant. Differences were not observed in the HBeAg seroconversion between each group. Differences in blood urea nitrogen, serum creatinine, creatine kinase, or other serious adverse effects were not observed in each group at the end of the 96-week treatment. Combination therapy and early ADV addition were the preferred approaches in the antiviral strategy for the treatment of hepatitis B-induced decompensated cirrhosis.

  13. Estimation of Rectal Dose Using Daily Megavoltage Cone-Beam Computed Tomography and Deformable Image Registration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akino, Yuichi, E-mail: akino@radonc.med.osaka-u.ac.jp; Department of Radiology, Osaka University Hospital, Suita, Osaka; Yoshioka, Yasuo

    2013-11-01

    Purpose: The actual dose delivered to critical organs will differ from the simulated dose because of interfractional organ motion and deformation. Here, we developed a method to estimate the rectal dose in prostate intensity modulated radiation therapy with consideration to interfractional organ motion using daily megavoltage cone-beam computed tomography (MVCBCT). Methods and Materials: Under exemption status from our institutional review board, we retrospectively reviewed 231 series of MVCBCT of 8 patients with prostate cancer. On both planning CT (pCT) and MVCBCT images, the rectal contours were delineated and the CT value within the contours was replaced by the mean CTmore » value within the pelvis, with the addition of 100 Hounsfield units. MVCBCT images were rigidly registered to pCT and then nonrigidly registered using B-Spline deformable image registration (DIR) with Velocity AI software. The concordance between the rectal contours on MVCBCT and pCT was evaluated using the Dice similarity coefficient (DSC). The dose distributions normalized for 1 fraction were also deformed and summed to estimate the actual total dose. Results: The DSC of all treatment fractions of 8 patients was improved from 0.75±0.04 (mean ±SD) to 0.90 ±0.02 by DIR. Six patients showed a decrease of the generalized equivalent uniform dose (gEUD) from total dose compared with treatment plans. Although the rectal volume of each treatment fraction did not show any correlation with the change in gEUD (R{sup 2}=0.18±0.13), the displacement of the center of gravity of rectal contours in the anterior-posterior (AP) direction showed an intermediate relationship (R{sup 2}=0.61±0.16). Conclusion: We developed a method for evaluation of rectal dose using DIR and MVCBCT images and showed the necessity of DIR for the evaluation of total dose. Displacement of the rectum in the AP direction showed a greater effect on the change in rectal dose compared with the rectal volume.« less

  14. Adverse events with bismuth salts for Helicobacter pylori eradication: Systematic review and meta-analysis

    PubMed Central

    Ford, Alexander C; Malfertheiner, Peter; Giguère, Monique; Santana, José; Khan, Mostafizur; Moayyedi, Paul

    2008-01-01

    AIM: To assess the safety of bismuth used in Helicobacter pylori (H pylori) eradication therapy regimens. METHODS: We conducted a systematic review and meta-analysis. MEDLINE and EMBASE were searched (up to October 2007) to identify randomised controlled trials comparing bismuth with placebo or no treatment, or bismuth salts in combination with antibiotics as part of eradication therapy with the same dose and duration of antibiotics alone or, in combination, with acid suppression. Total numbers of adverse events were recorded. Data were pooled and expressed as relative risks with 95% confidence intervals (CI). RESULTS: We identified 35 randomised controlled trials containing 4763 patients. There were no serious adverse events occurring with bismuth therapy. There was no statistically significant difference detected in total adverse events with bismuth [relative risk (RR) = 1.01; 95% CI: 0.87-1.16], specific individual adverse events, with the exception of dark stools (RR = 5.06; 95% CI: 1.59-16.12), or adverse events leading to withdrawal of therapy (RR = 0.86; 95% CI: 0.54-1.37). CONCLUSION: Bismuth for the treatment of H pylori is safe and well-tolerated. The only adverse event occurring significantly more commonly was dark stools. PMID:19109870

  15. Improving treatment geometries in total skin electron therapy: Experimental investigation of linac angles and floor scatter dose contributions using Cherenkov imaging.

    PubMed

    Andreozzi, Jacqueline M; Brůža, Petr; Tendler, Irwin I; Mooney, Karen E; Jarvis, Lesley A; Cammin, Jochen; Li, Harold; Pogue, Brian W; Gladstone, David J

    2018-06-01

    The purpose of this study was to identify the optimal treatment geometry for total skin electron therapy (TSET) using a new optimization metric from Cherenkov image analysis, and to investigate the sensitivity of the Cherenkov imaging method to floor scatter effects in this unique treatment setup. Cherenkov imaging using an intensified charge coupled device (ICCD) was employed to measure the relative surface dose distribution as a 2D image in the total skin electron treatment plane. A 1.2 m × 2.2 m × 1 cm white polyethylene sheet was placed vertically at a source to surface distance (SSD) of 300 cm, and irradiated with 6 MeV high dose rate TSET beams. The linear accelerator coordinate system used stipulates 0° is the bottom of the gantry arc, and progresses counterclockwise so that gantry angle 270° produces a horizontal beam orthogonal to the treatment plane. First, all unique pairs of treatment beams were analyzed to determine the performance of the currently recommended symmetric treatment angles (±20° from the horizontal), compared to treatment geometries unconstrained to upholding gantry angle symmetry. This was performed on two medical linear accelerators (linacs). Second, the extent of the floor scatter contributions to measured surface dose at the extended SSD required for TSET were imaged using three gantry angles of incidence: 270° (horizontal), 253° (-17°), and 240° (-30°). Images of the surface dose profile at each angle were compared to the standard concrete floor when steel plates, polyvinyl chloride (PVC), and solid water were placed on the ground at the base of the treatment plane. Postprocessing of these images allowed for comparison of floor material-based scatter profiles with previously published simulation results. Analysis of the symmetric treatment geometry (270 ± 20°) and the identified optimal treatment geometry (270 + 23° and 270 - 17°) showed a 16% increase in the 90% isodose area for the latter field pair on the first linac. The optimal asymmetric pair for the second linac (270 + 25° and 270 - 17°) provided a 52% increase in the 90% isodose area when compared to the symmetric geometry. Difference images between Cherenkov images captured with test materials (steel, PVC, and solid water) and the control (concrete floor) demonstrated relative changes in the two-dimensional (2D) dose profile over a 1 × 1.9 m region of interest (ROI) that were consistent with published simulation data. Qualitative observation of the residual images demonstrates localized increases and decreases with respect to the change in floor material and gantry angle. The most significant changes occurred when the beam was most directly impinging the floor (gantry angle 240°, horizontal -30°), where the PVC floor material decreased scatter dose by 1-3% in 7.2% of the total ROI area, and the steel plate increased scatter dose by 1-3% in 7.0% of the total ROI area. An updated Cherenkov imaging method identified asymmetric, machine-dependent TSET field angle pairs that provided much larger 90% isodose areas than the commonly adopted symmetric geometry suggested by Task Group 30 Report 23. A novel demonstration of scatter dose Cherenkov imaging in the TSET field was established. © 2018 American Association of Physicists in Medicine.

  16. Increased Subventricular Zone Radiation Dose Correlates With Survival in Glioblastoma Patients After Gross Total Resection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Linda; Duke University School of Medicine, Durham, North Carolina; Guerrero-Cazares, Hugo

    2013-07-15

    Purpose: Neural progenitor cells in the subventricular zone (SVZ) have a controversial role in glioblastoma multiforme (GBM) as potential tumor-initiating cells. The purpose of this study was to examine the relationship between radiation dose to the SVZ and survival in GBM patients. Methods and Materials: The study included 116 patients with primary GBM treated at the Johns Hopkins Hospital between 2006 and 2009. All patients underwent surgical resection followed by adjuvant radiation therapy with intensity modulated radiation therapy (60 Gy/30 fractions) and concomitant temozolomide. Ipsilateral, contralateral, and bilateral SVZs were contoured on treatment plans by use of coregistered magnetic resonancemore » imaging and computed tomography. Multivariate Cox regression was used to examine the relationship between mean SVZ dose and progression-free survival (PFS), as well as overall survival (OS). Age, Karnofsky Performance Status score, and extent of resection were used as covariates. The median age was 58 years (range, 29-80 years). Results: Of the patients, 12% underwent biopsy, 53% had subtotal resection (STR), and 35% had gross total resection (GTR). The Karnofsky Performance Status score was less than 90 in 54 patients and was 90 or greater in 62 patients. The median ipsilateral, contralateral, and bilateral mean SVZ doses were 48.7 Gy, 34.4 Gy, and 41.5 Gy, respectively. Among patients who underwent GTR, a mean ipsilateral SVZ dose of 40 Gy or greater was associated with a significantly improved PFS compared with patients who received less than 40 Gy (15.1 months vs 10.3 months; P=.028; hazard ratio, 0.385 [95% confidence interval, 0.165-0.901]) but not in patients undergoing STR or biopsy. The subgroup of GTR patients who received an ipsilateral dose of 40 Gy or greater also had a significantly improved OS (17.5 months vs 15.6 months; P=.027; hazard ratio, 0.385 [95% confidence interval, 0.165-0.895]). No association was found between SVZ radiation dose and PFS and OS among patients who underwent STR or biopsy. Conclusion: A mean radiation dose of 40 Gy or greater to the ipsilateral SVZ was associated with a significantly improved PFS and OS in patients with GBM after GTR.« less

  17. Short-term response of bone turnover to low-dose oral contraceptives in exercising women with hypothalamic amenorrhea.

    PubMed

    Vescovi, Jason D; VanHeest, Jaci L; De Souza, Mary Jane

    2008-02-01

    We examined the response of bone turnover markers and indices of energy status after 2 weeks of oral contraceptive (OC) therapy in premenopausal women with exercise-associated menstrual disturbances (EAMD). Six women with EAMD received one 28-day cycle of a triphasic OC containing 180-250 mcg norgestimate/25 mcg ethinyl estradiol (EAMD+OC) and six were controls (EAMD controls). Bone turnover markers amino-terminal propeptide of Type I procollagen and serum carboxy-terminal telopeptides of Type I collagen (PINP and SCTX-I) were assessed at baseline and after 2 weeks of OC therapy (EAMD+OC) or after a 30-day monitoring period (EAMD controls). Total triiodothyronine, resting energy expenditure (REE) and dietary intake were assessed as secondary end points. The absolute and percent changes from baseline in the primary and secondary outcomes were evaluated using an analysis of covariance, adjusting for baseline values of the corresponding outcome. Compared to EAMD controls, a significant change from baseline was observed in the EAMD+OC group for PINP (mean+/-SEM, 9.9+/-6.1 vs. -33.9+/-9.0 mcg/L; p=.005) and SCTX-I (-0.02+/-0.11 vs. -0.25+/-0.07 ng/mL; p=.017), but not osteoprotegerin (-0.53+/-0.22 vs. 0.20+/-0.44 pmol/L; p=.429) after 2 weeks (14.7+/-0.3 days) of OC therapy. Total triiodothyronine levels were elevated in the EAMD+OC group after therapy compared with EAMD controls (19.7+/-4.1 vs. -8.4+/-4.9 ng/dL; p=.002); however, no differences between groups were observed for the changes in REE or dietary intake. Our data demonstrate that 2 weeks of low-dose OC therapy rapidly reduced markers of bone resorption and formation, without any significant impact on energy status in women with EAMD.

  18. Beam Path Toxicities to Non-Target Structures During Intensity-Modulated Radiation Therapy for Head and Neck Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenthal, David I.; Chambers, Mark S.; Fuller, Clifton D.

    2008-11-01

    Background: Intensity-modulated radiation therapy (IMRT) beams traverse nontarget normal structures not irradiated during three-dimensional conformal RT (3D-CRT) for head and neck cancer (HNC). This study estimates the doses and toxicities to nontarget structures during IMRT. Materials and Methods: Oropharyngeal cancer IMRT and 3D-CRT cases were reviewed. Dose-volume histograms (DVH) were used to evaluate radiation dose to the lip, cochlea, brainstem, occipital scalp, and segments of the mandible. Toxicity rates were compared for 3D-CRT, IMRT alone, or IMRT with concurrent cisplatin. Descriptive statistics and exploratory recursive partitioning analysis were used to estimate dose 'breakpoints' associated with observed toxicities. Results: A totalmore » of 160 patients were evaluated for toxicity; 60 had detailed DVH evaluation and 15 had 3D-CRT plan comparison. Comparing IMRT with 3D-CRT, there was significant (p {<=} 0.002) nonparametric differential dose to all clinically significant structures of interest. Thirty percent of IMRT patients had headaches and 40% had occipital scalp alopecia. A total of 76% and 38% of patients treated with IMRT alone had nausea and vomiting, compared with 99% and 68%, respectively, of those with concurrent cisplatin. IMRT had a markedly distinct toxicity profile than 3D-CRT. In recursive partitioning analysis, National Cancer Institute's Common Toxicity Criteria adverse effects 3.0 nausea and vomiting, scalp alopecia and anterior mucositis were associated with reconstructed mean brainstem dose >36 Gy, occipital scalp dose >30 Gy, and anterior mandible dose >34 Gy, respectively. Conclusions: Dose reduction to specified structures during IMRT implies an increased beam path dose to alternate nontarget structures that may result in clinical toxicities that were uncommon with previous, less conformal approaches. These findings have implications for IMRT treatment planning and research, toxicity assessment, and multidisciplinary patient management.« less

  19. OUT-OF-FIELD DOSES IN CHILDREN TREATED FOR LARGE ARTERIOVENOUS MALFORMATIONS USING HYPOFRACTIONATED GAMMA KNIFE RADIOSURGERY AND INTENSITY-MODULATED RADIATION THERAPY.

    PubMed

    De Saint-Hubert, Marijke; Majer, Marija; Hršak, Hrvoje; Heinrich, Zdravko; Kneževic, Željka; Miljanic, Saveta; Porwol, Paulina; Stolarczyk, Liliana; Vanhavere, Filip; Harrison, Roger M

    2018-01-17

    The purpose of this study was to measure out-of-field organ doses in two anthropomorphic child phantoms for the treatment of large brain arteriovenous malformations (AVMs) using hypofractionated gamma knife (GK) radiosurgery and to compare these with an alternative treatment using intensity-modulated radiation therapy (IMRT). Target volume was identical in size and shape in all cases. Radiophotoluminescent (RPL), thermoluminescent (TL) and optically stimulated luminescent (OSL) dosimeters were used for out-of-field dosimetry during GK treatment and a good agreement within 1-2% between results was shown. In addition, the use of multiple dosimetry systems strengthens the reliability of the findings. The number of GK isocentres was confirmed to be important for the magnitude of out-of-field doses. Measured GK doses for the same distance from the target, when expressed per target dose and isocentre, were comparable in both phantoms. GK out-of-field doses averaged for both phantoms were evaluated to be 120 mGy/Gy for eyes then sharply reduced to 20 mGy/Gy for mandible and slowly reduced up to 0.8 mGy/Gy for testes. Taking into account the fractionation regimen used to treat AVM patients, the total treatment organ doses to the out-of-field organs were calculated and compared with IMRT. The eyes were better spared with GK whilst for more distant organs doses were up to a factor of 2.8 and 4 times larger for GK compared to IMRT in 5-year and 10-year old phantoms, respectively. Presented out-of-field dose values are specific for the investigated AVM case, phantoms and treatment plans used for GK and IMRT, but provide useful information about out-of-field dose levels and emphasise their importance. © The Author(s) 2018. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. SU-F-T-198: Dosimetric Comparison of Carbon and Proton Radiotherapy for Recurrent Nasopharynx Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheng, Y; Zhao, J; Wang, W

    2016-06-15

    Purpose: Various radiotherapy planning methods for locally recurrent nasopharynx carcinoma (R-NPC) have been proposed. The purpose of this study was to compare carbon and proton therapy for the treatment of R-NPC in terms of dose coverage for target volume and sparing for organs at risk (OARs). Methods: Six patients who were suffering from R-NPC and treated using carbon therapy were selected for this study. Treatment plans with a total dose of 57.5Gy (RBE) in 23 fractions were made using SIEMENS Syngo V11. An intensity-modulated radiotherapy optimization method was chosen for carbon plans (IMCT) while for proton plans both intensity-modulated radiotherapymore » (IMPT) and single beam optimization (proton-SBO) methods were chosen. Dose distributions, dose volume parameters, and selected dosimetric indices for target volumes and OARs were compared for all treatment plans. Results: All plans provided comparable PTV coverage. The volume covered by 95% of the prescribed dose was comparable for all three plans. The average values were 96.11%, 96.24% and 96.11% for IMCT, IMPT, and proton-SBO respectively. A significant reduction of the 80% and 50% dose volumes were observed for the IMCT plans compared to the IMPT and proton-SBO plans. Critical organs lateral to the target such as brain stem and spinal cord were better spared by IMPT than by proton-SBO, while IMCT spared those organs best. For organs in the beam path, such as parotid glands, the mean dose results were similar for all three plans. Conclusion: Carbon plans yielded better dose conformity than proton plans. They provided similar or better target coverage while significantly lowering the dose for normal tissues. Dose sparing for critical organs in IMPT plans was better than proton-SBO, however, IMPT is known to be more sensitive to range uncertainties. For proton plans it is essential to find a balance between the two optimization methods.« less

  1. Development of clinical application for a nutritional prescription support system for total parenteral/enteral nutrition.

    PubMed

    Masuda, Syuzo; Oka, Ryusho; Uwai, Koji; Matsuda, Yumi; Shiraishi, Tadashi; Nakagawa, Yoshito; Shoji, Tohru; Mihara, Chie; Takeshita, Mitsuhiro; Ozawa, Koichiro

    2009-09-01

    One of the important roles of pharmacists as members of a nutrition support team is nutritional prescription support. We developed a nutritional prescription support system (NPSS) that facilitates prescription support and analysis and evaluated its usefulness in nutritional therapy. An NPSS for prescription support and the management of patient information was created. With this NPSS, the nutritional status was assessed, and, on the basis of the results, such variables as the total energy expenditure were calculated. This system allows prescription support for parenteral nutrition (PN) therapy, enteral nutrition (EN) therapy, and the transition period between them. This system was used for 2 representative patients and evaluated. In a malnourished patient receiving oral warfarin, EN solutions were compared by means of the NPSS, and an appropriate EN solution was selected. In addition, the prothrombin time-international normalized ratio was monitored, and favorable results were obtained regarding the adjustment of the warfarin dose and nutritional management. In a patient with aspiration pneumonia, continuous nutritional management to EN from PN therapy was straightforwardly performed with the NPSS. This NPSS allows rapid, comprehensive nutritional management during the transition period to EN from PN therapy, despite these therapies being considered separately in conventional nutritional management. The NPSS is useful for simplifying prescription support and facilitating information sharing among members of a nutrition support team.

  2. The influence of the dose calculation resolution of VMAT plans on the calculated dose for eye lens and optic pathway.

    PubMed

    Park, Jong Min; Park, So-Yeon; Kim, Jung-In; Carlson, Joel; Kim, Jin Ho

    2017-03-01

    To investigate the effect of dose calculation grid on calculated dose-volumetric parameters for eye lenses and optic pathways. A total of 30 patients treated using the volumetric modulated arc therapy (VMAT) technique, were retrospectively selected. For each patient, dose distributions were calculated with calculation grids ranging from 1 to 5 mm at 1 mm intervals. Identical structures were used for VMAT planning. The changes in dose-volumetric parameters according to the size of the calculation grid were investigated. Compared to dose calculation with 1 mm grid, the maximum doses to the eye lens with calculation grids of 2, 3, 4 and 5 mm increased by 0.2 ± 0.2 Gy, 0.5 ± 0.5 Gy, 0.9 ± 0.8 Gy and 1.7 ± 1.5 Gy on average, respectively. The Spearman's correlation coefficient between dose gradients near structures vs. the differences between the calculated doses with 1 mm grid and those with 5 mm grid, were 0.380 (p < 0.001). For the accurate calculation of dose distributions, as well as efficiency, using a grid size of 2 mm appears to be the most appropriate choice.

  3. Dose specification for radiation therapy: dose to water or dose to medium?

    NASA Astrophysics Data System (ADS)

    Ma, C.-M.; Li, Jinsheng

    2011-05-01

    The Monte Carlo method enables accurate dose calculation for radiation therapy treatment planning and has been implemented in some commercial treatment planning systems. Unlike conventional dose calculation algorithms that provide patient dose information in terms of dose to water with variable electron density, the Monte Carlo method calculates the energy deposition in different media and expresses dose to a medium. This paper discusses the differences in dose calculated using water with different electron densities and that calculated for different biological media and the clinical issues on dose specification including dose prescription and plan evaluation using dose to water and dose to medium. We will demonstrate that conventional photon dose calculation algorithms compute doses similar to those simulated by Monte Carlo using water with different electron densities, which are close (<4% differences) to doses to media but significantly different (up to 11%) from doses to water converted from doses to media following American Association of Physicists in Medicine (AAPM) Task Group 105 recommendations. Our results suggest that for consistency with previous radiation therapy experience Monte Carlo photon algorithms report dose to medium for radiotherapy dose prescription, treatment plan evaluation and treatment outcome analysis.

  4. Use of Magnetic Resonance Imaging to Monitor Iron Overload

    PubMed Central

    Wood, John C.

    2014-01-01

    SYNOPSIS Treatment of iron overload requires robust estimates of total body iron burden and its response to iron chelation therapy. Compliance with chelation therapy varies considerably among patients and individual reporting is notoriously unreliable. Even with perfect compliance, intersubject variability in chelator effectiveness is extremely high, necessitating reliable iron estimates to guide dose titration. In addition, each chelator has a unique profile with respect to clearing iron stores from different organs. This chapter will present the tools available to clinicians monitoring their patients, focusing on non-invasive magnetic resonance imaging methods because they have become the de-facto standard of care. PMID:25064711

  5. Radioactivity of peat mud used in therapy.

    PubMed

    Karpińska, Maria; Mnich, Krystian; Kapała, Jacek; Bielawska, Agnieszka; Kulesza, Grzegorz; Mnich, Stanisław

    2016-02-01

    The aim of the study was to determine the contents of natural and artificial isotopes in peat mud and to estimate the radiation dose absorbed via skin in patients during standard peat mud treatment. The analysis included 37 samples collected from 8 spas in Poland. The measurements of isotope concentration activity were conducted with the use of gamma spectrometry methods. The skin dose in a standard peat mud bath therapy is approximately 300 nSv. The effective dose of such therapy is considered to be 22 nSv. The doses absorbed during peat mud therapy are 5 orders of magnitude lower than effective annual dose absorbed from the natural radiation background by a statistical Pole (3.5 mSv). Neither therapeutic nor harmful effect is probable in case of such a small dose of ionising radiation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Early initiation of low-dose hydrocortisone treatment for septic shock in adults: A randomized clinical trial.

    PubMed

    Lv, Qing-Quan; Gu, Xiao-Hua; Chen, Qi-Hong; Yu, Jiang-Quan; Zheng, Rui-Qiang

    2017-12-01

    Physiologic dose hydrocortisone is part of the suggested adjuvant therapies for patients with septic shock. However, the association between the corticosteroid therapy and mortality in patients with septic shock is still not clear. Some authors considered that the mortality is related to the time frame between development of septic shock and start of low dose hydrocortisone. Thus we designed a placebo-controlled, randomized clinical trial to assess the importance of early initiation of low dose hydrocortisone for the final outcome. A total of 118 patients with septic shock were recruited in the study. All eligible patients were randomized to receive hydrocortisone (n=58) or normal saline (n=60). The study medication (hydrocortisone and normal saline) was initiated simultaneously with vasopressors. The primary end-point was 28-day mortality. The secondary end-points were the reversal of shock, in-hospital mortality and the duration of ICU and hospital stay. The proportion of patients with reversal of shock was similar in the two groups (P=0.602); There were no significant differences in 28-day or hospital all-cause mortality; length of stay in the ICU or hospital between patients treated with hydrocortisone or normal saline. The early initiation of low-dose of hydrocortisone did not decrease the risk of mortality, and the length of stay in the ICU or hospital in adults with septic shock. www.clinicaltrials.govNCT02580240. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Treatment planning for internal emitter therapy: Methods, applications and clinical implications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sgouros, G.

    1999-01-01

    Treatment planning involves three basic steps: (1) a procedure must be devised that will provide the most relevant information, (2) the procedure must be applied and (3) the resulting information must be translated into a definition of the optimum implementation. There are varying degrees of treatment planning that may be implemented in internal emitter therapy. As in chemotherapy, the information from a Phase 1 study may be used to treat patients based upon body surface area. If treatment planning is included on a patient-specific basis, a pretherapy, trace-labeled, administration of the radiopharmaceutical is generally required. The data collected following themore » tracer dose may range from time-activity curves of blood and whole-body for use in blood, marrow or total body absorbed dose estimation to patient imaging for three-dimensional internal emitter dosimetry. The most ambitious approach requires a three-dimensional set of images representing radionuclide distribution (SPECT or PET) and a corresponding set of images representing anatomy (CT or MRI). The absorbed dose (or dose-rate) distribution may be obtained by convolution of a point kernel with the radioactivity distribution or by direct Monte Carlo calculation. A critical requirement for both techniques is the development of an overall structure that makes it possible, in a routine manner, to input the images, to identify the structures of interest and to display the results of the dose calculations in a clinically relevant manner. 52 refs., 4 figs., 1 tab.« less

  8. Low dose Photofrin PDT for recurrent in-situ squamous cell tumors of the head and neck

    NASA Astrophysics Data System (ADS)

    Allison, R. R.; Austerlitz, C.; Sheng, C.; Mota, H.; Brodish, B.; Camnitz, P.; Sibata, C. H.

    2009-06-01

    Multifocal recurrence of in-situ squamous cell cancer of the oral cavity, pharynx and vocal cord following surgical failure can be a therapeutic dilemma. Salvage surgery or radiation may be an option but morbidity can be significant. We evaluated the potential role of low dose Photofrin (1.2mg/Kg) Photodynamic Therapy for this cohort of patients. A total of 25 patients with multifocal recurrent in-situ squamous cell cancer of the oral cavity, pharynx and vocal cord who had failed local resection, and where additional surgery or radiation therapy would likely result in permanent morbidity, were offered Photodynamic Therapy. PDT consisted of off label infusion of Photofrin (1.2mg/kg) followed 48 hours later by illumination at 630nm employing a light diffuser (300J) and/or microlens (150Jcm2). All patients completed their prescribed PDT and no patient has been lost to follow up (minimum 1 year). No photosensitivity reactions were noted. No significant morbidity was seen. All patients were able to maintain oral nutrition. Procedure related pain was well controlled by one week of oral narcotics. At one month post PDT all patients were biopsy negative in the treatment region and no failures within the treatment region have been noted. No fibrosis or permanent PDT morbidity has been seen with follow up to three years. Vocal cord and voice function were excellent. Three patients developed new regions of in-situ disease outside the PDT fields, two underwent additional PDT and one had laser resection. Low dose Photofrin PDT offers excellent palliation and durable local control of recurrent in-situ squamous cell cancers of the oral cavity, pharynx and true cords. This is a well tolerated therapy. Low dose Photofrin appears to improve selectivity and minimize normal tissue injury. It should be tested in a larger patient population.

  9. Antimicrobials used for surgical prophylaxis by equine veterinary practitioners in Australia.

    PubMed

    Hardefeldt, L Y; Browning, G F; Thursky, K; Gilkerson, J R; Billman-Jacobe, H; Stevenson, M A; Bailey, K E

    2018-01-01

    Antimicrobials are widely used in Australian veterinary practices, but no investigation into the classes of antimicrobials used, or the appropriateness of use in horses, has been conducted. The aim of the study was to describe antimicrobial use for surgical prophylaxis in equine practice in Australia. Cross-sectional questionnaire survey. An online questionnaire was used to document antimicrobial usage patterns. Information solicited in the questionnaire included demographic details of the respondents, the frequency with which antimicrobials were used for specific surgical conditions (including the dose, timing and duration of therapy) and practice antimicrobial use policies and sources of information about antimicrobials and their uses. A total of 337 members of the Australian veterinary profession completed the survey. Generally, the choice of antimicrobial was appropriate for the specified equine surgical condition, but the dose and duration of therapy varied greatly. While there was poor optimal compliance with British Equine Veterinary Association guidelines in all scenarios (range 1-15%), except removal of a nonulcerated dermal mass (42%), suboptimal compliance (compliant antimicrobial drug selection but inappropriate timing, dose or duration of therapy) was moderate for all scenarios (range 48-68%), except for an uninfected contaminated wound over the thorax, where both optimal and suboptimal compliance was very poor (1%). Veterinarians practicing at a university hospital had higher odds of compliance than general practice veterinarians (Odds ratio 3.2, 95% CI, 1.1-8.9, P = 0.03). Many survey responses were collected at conferences which may introduce selection bias, as veterinarians attending conferences may be more likely to have been exposed to contemporary antimicrobial prescribing recommendations. Antimicrobial use guidelines need to be developed and promoted to improve the responsible use of antimicrobials in equine practice in Australia. An emphasis should be placed on antimicrobial therapy for wounds and appropriate dosing for procaine penicillin. © 2017 EVJ Ltd.

  10. Long-term efficacy and safety of vildagliptin add-on therapy in type 2 diabetes mellitus with insulin treatment.

    PubMed

    Kanazawa, Ippei; Tanaka, Ken-Ichiro; Notsu, Masakazu; Tanaka, Sayuri; Kiyohara, Nobuaki; Koike, Sayo; Yamane, Yuko; Tada, Yuko; Sasaki, Motofumi; Yamauchi, Mika; Sugimoto, Toshitsugu

    2017-01-01

    The use of dipeptidyl peptidase (DPP)-4 inhibitors in patients with type 2 diabetes treated with insulin may be beneficial. However, the long-term efficacy and safety of vildagliptin add-on therapy in these patients remains unclear. A total of 73 patients with type 2 diabetes treated with insulin were randomly assigned to receive either add-on therapy of vildagliptin (n=37) or conventional therapy without DPP-4 inhibitors (n=36) for glucose control. Hemoglobin A1c (HbA1c) levels, dose and number of insulin injections, number of hypoglycemia episodes, and liver and renal function were monitored for 2years. The baseline characteristics of subjects, including age, dose of insulin injections, or HbA1c levels, did not differ between the two groups. In the vildagliptin group, HbA1c levels significantly decreased and the significance of HbA1c reduction was maintained for 24months (from 8.0±1.2% to 7.4±1.0%, p<0.05, at the end of observational period). In addition, the dose and number of insulin injections significantly reduced (-5.6units, p<0.01, and -0.9 times, p<0.001). However, these parameters were unchanged in the control group. The number of patients who experienced three or more episodes of hypoglycemia per year was significantly lower in the vildagliptin group (n=4) than in the control group (n=11) (odds ratio, 0.28; 95% confidence interval, 0.08-0.97; p<0.05). Vildagliptin as an add-on to insulin treatment for 24months was well tolerated and led to sustained reductions in HbA1c, the dose and number of insulin injections, and the risk of hypoglycemia. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Weight Change After Smoking Cessation Using Variable Doses of Transdermal Nicotine Replacement

    PubMed Central

    Dale, Lowell C; Schroeder, Darrell R; Wolter, Troy D; Croghan, Ivana T; Hurt, Richard D; Offord, Kenneth P

    1998-01-01

    OBJECTIVE Examine weight change in subjects receiving variable doses of transdermal nicotine replacement for smoking cessation. DESIGN Randomized, double-blind clinical trial. SETTING One-week inpatient treatment with outpatient follow-up through 1 year. INTERVENTION This report examines weight change after smoking cessation for 70 subjects randomized to placebo or to 11, 22, or 44 mg/d doses of transdermal nicotine. The study included 1 week of intensive inpatient treatment for nicotine dependence with active patch therapy continuing for another 7 weeks. Counseling sessions were provided weekly for the 8 weeks of patch therapy and with long-term follow-up visits at 3, 6, 9, and 12 months. MEASUREMENTS AND MAIN RESULTS Forty-two subjects were confirmed biochemically (i.e., by expired carbon monoxide) to be nonsmokers at all weekly visits during patch therapy. Their 8-week weight change from baseline was 3.0 ±2.0 kg. For these subjects, 8-week weight change was found to be negatively correlated with percentage of cotinine replacement (r=−.38, p=.012) and positively correlated with baseline weight (r=.48, p=.001), and age (r=.35, p=.025). Men had higher (p=.003) 8-week weight gain (4.0 ±1.8 kg) than women (2.1 ±1.7 kg). Of the 21 subjects who abstained continuously for the entire year, 20 had their weight measured at 1-year follow-up. Among these 20 subjects, 1-year weight change was not found to be associated with gender, baseline weight, baseline smoking rate, total dose of transdermal nicotine, or average percentage of cotinine replacement during the 8 weeks of patch therapy. CONCLUSIONS This study suggests that higher replacement levels of nicotine may delay postcessation weight gain. This effect is consistent for both men and women. We could not identify any factors that predict weight change with long-term abstinence from smoking. PMID:9462489

  12. Factors Associated with Myelosuppression Related to Low-Dose Methotrexate Therapy for Inflammatory Rheumatic Diseases

    PubMed Central

    Mori, Shunsuke; Hidaka, Michihiro; Kawakita, Toshiro; Hidaka, Toshihiko; Tsuda, Hiroyuki; Yoshitama, Tamami; Migita, Kiyoshi; Ueki, Yukitaka

    2016-01-01

    Objective Severe myelosuppression is a serious concern in the management of rheumatic disease patients receiving methotrexate (MTX) therapy. This study was intended to explore factors associated with the development of MTX-related myelosuppression and its disease severity. Methods We retrospectively examined a total of 40 cases of MTX-related myelosuppression that had been filed in the registries of participating rheumatology and hematology divisions. Data before onset were compared with those of 120 controls matched for age and sex. Cytopenia was graded according to the National Cancer Institute criteria for adverse events. Data before and at onset were compared between the severe and non-severe groups. Results Non-use of folic acid supplements, concurrent medications, and low renal function were significantly associated with the development of myelosuppression (p < 0.001, p < 0.001, and p = 0.002, respectively). In addition, significantly lower MTX dosages, higher blood cell counts, and lower hemoglobin levels were seen in the myelosuppression group (p < 0.001). No patients exhibited leukocytopenia, neutropenia, or thrombocytopenia in routine blood monitoring taken within the past month. One-fourth developed myelosuppression within the first two months (an early-onset period). Myelosuppression was severe in approximately 40% of patients. Hypoalbuminemia and non-use of folic acid supplements were significantly associated with the severity of pancytopenia (p = 0.001 and 0.008, respectively). Besides these two factors, early onset and the use of lower doses of MTX were significantly associated with the severity of neutropenia (p = 0.003, 0.007, 0.003, and 0.002, respectively). Conclusions Myelosuppression can occur abruptly at any time during low-dose MTX therapy, but severe neutropenia is more likely to occur in the early-onset period of this therapy. Contrary to our expectations, disease severity was not dependent on MTX doses. Serum albumin levels and folic acid supplementation are the important factors affecting the severity of MTX-related pancytopenia and neutropenia. PMID:27128679

  13. Correlation of missed doses of enoxaparin with increased incidence of deep vein thrombosis in trauma and general surgery patients.

    PubMed

    Louis, Scott G; Sato, Misa; Geraci, Travis; Anderson, Ross; Cho, S David; Van, Philbert Y; Barton, Jeffrey S; Riha, Gordon M; Underwood, Samantha; Differding, Jerome; Watters, Jennifer M; Schreiber, Martin A

    2014-04-01

    Enoxaparin sodium is widely used for deep vein thrombosis (DVT) prophylaxis, yet DVT rates remain high in the trauma and general surgery populations. Missed doses during hospitalization are common. To determine if missed doses of enoxaparin correlate with DVT formation. Data were prospectively collected among 202 trauma and general surgery patients admitted to a level I trauma center. Deep vein thrombosis screening was performed using a rigorous standardized protocol. The overall incidence of DVT was 15.8%. In total, 58.9% of patients missed at least 1 dose of enoxaparin. The DVTs occurred in 23.5% of patients who missed at least 1 dose and in 4.8% of patients who did not (P < .01). On univariate analysis, the need for mechanical ventilation (71.8% vs 44.1%), the performance of more than 1 operation (59.3% vs 40.0%), and male sex (75% vs 56%) were associated with DVT formation (P < .05 for all). A bivariate logistic regression was then performed, which revealed age 50 years or older and interrupted enoxaparin therapy as the only independent risk factors for DVT formation. The DVT rate did not differ between trauma and general surgery populations or in patients receiving once-daily vs twice-daily dosing regimens. Interrupted enoxaparin therapy and age 50 years or older are associated with DVT formation among trauma and general surgery patients. Missed doses occur commonly and are the only identified risk factor for DVT that can be ameliorated by physicians. Efforts to minimize interrupted enoxaparin prophylaxis in patients at risk for DVT should be optimized.

  14. Intensity Modulated Radiation Therapy With Dose Painting to Treat Rhabdomyosarcoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Joanna C.; Dharmarajan, Kavita V.; Wexler, Leonard H.

    Purpose: To examine local control and patterns of failure in rhabdomyosarcoma patients treated with intensity modulated radiation therapy (RT) with dose painting (DP-IMRT). Patients and Methods: A total of 41 patients underwent DP-IMRT with chemotherapy for definitive treatment. Nineteen also underwent surgery with or without intraoperative RT. Fifty-six percent had alveolar histologic features. The median interval from beginning chemotherapy to RT was 17 weeks (range, 4-25). Very young children who underwent second-look procedures with or without intraoperative RT received reduced doses of 24-36 Gy in 1.4-1.8-Gy fractions. Young adults received 50.4 Gy to the primary tumor and lower doses ofmore » 36 Gy in 1.8-Gy fractions to at-risk lymph node chains. Results: With 22 months of median follow-up, the actuarial local control rate was 90%. Patients aged {<=}7 years who received reduced overall and fractional doses had 100% local control, and young adults had 79% (P=.07) local control. Three local failures were identified in young adults whose primary target volumes had received 50.4 Gy in 1.8-Gy fractions. Conclusions: DP-IMRT with lower fractional and cumulative doses is feasible for very young children after second-look procedures with or without intraoperative RT. DP-IMRT is also feasible in adolescents and young adults with aggressive disease who would benefit from prophylactic RT to high-risk lymph node chains, although dose escalation might be warranted for improved local control. With limited follow-up, it appears that DP-IMRT produces local control rates comparable to those of sequential IMRT in patients with rhabdomyosarcoma.« less

  15. Dosimetric impact of daily setup variations during treatment of canine nasal tumors using intensity-modulated radiation therapy.

    PubMed

    Deveau, Michael A; Gutiérrez, Alonso N; Mackie, Thomas R; Tomé, Wolfgang A; Forrest, Lisa J

    2010-01-01

    Intensity-modulated radiation therapy (IMRT) can be employed to yield precise dose distributions that tightly conform to targets and reduce high doses to normal structures by generating steep dose gradients. Because of these sharp gradients, daily setup variations may have an adverse effect on clinical outcome such that an adjacent normal structure may be overdosed and/or the target may be underdosed. This study provides a detailed analysis of the impact of daily setup variations on optimized IMRT canine nasal tumor treatment plans when variations are not accounted for due to the lack of image guidance. Setup histories of ten patients with nasal tumors previously treated using helical tomotherapy were replanned retrospectively to study the impact of daily setup variations on IMRT dose distributions. Daily setup shifts were applied to IMRT plans on a fraction-by-fraction basis. Using mattress immobilization and laser alignment, mean setup error magnitude in any single dimension was at least 2.5 mm (0-10.0 mm). With inclusions of all three translational coordinates, mean composite offset vector was 5.9 +/- 3.3 mm. Due to variations, a loss of equivalent uniform dose for target volumes of up to 5.6% was noted which corresponded to a potential loss in tumor control probability of 39.5%. Overdosing of eyes and brain was noted by increases in mean normalized total dose and highest normalized dose given to 2% of the volume. Findings suggest that successful implementation of canine nasal IMRT requires daily image guidance to ensure accurate delivery of precise IMRT distributions when non-rigid immobilization techniques are utilized. Unrecognized geographical misses may result in tumor recurrence and/or radiation toxicities to the eyes and brain.

  16. DOSIMETRIC IMPACT OF DAILY SETUP VARIATIONS DURING TREATMENT OF CANINE NASAL TUMORS USING INTENSITY-MODULATED RADIATION THERAPY

    PubMed Central

    Deveau, Michael A.; Gutiérrez, Alonso N.; Mackie, Thomas R.; Tomé, Wolfgang A.; Forrest, Lisa J.

    2009-01-01

    Intensity-modulated radiation therapy (IMRT) can be employed to yield precise dose distributions that tightly conform to targets and reduce high doses to normal structures by generating steep dose gradients. Because of these sharp gradients, daily setup variations may have an adverse effect on clinical outcome such that an adjacent normal structure may be overdosed and/or the target may be underdosed. This study provides a detailed analysis of the impact of daily setup variations on optimized IMRT canine nasal tumor treatment plans when variations are not accounted for due to the lack of image guidance. Setup histories of ten patients with nasal tumors previously treated using helical tomotherapy were replanned retrospectively to study the impact of daily setup variations on IMRT dose distributions. Daily setup shifts were applied to IMRT plans on a fraction-by-fraction basis. Using mattress immobilization and laser alignment, mean setup error magnitude in any single dimension was at least 2.5mm (0-10.0mm). With inclusions of all three translational coordinates, mean composite offset vector was 5.9±3.3mm. Due to variations, a loss of equivalent uniform dose (EUD) for target volumes of up to 5.6% was noted which corresponded to a potential loss in TCP of 39.5%. Overdosing of eyes and brain was noted by increases in mean normalized total dose (NTDmean) and highest normalized dose given to 2% of the volume (NTD2%). Findings suggest that successful implementation of canine nasal IMRT requires daily image guidance to ensure accurate delivery of precise IMRT distributions when non-rigid immobilization techniques are utilized. Unrecognized geographical misses may result in tumor recurrence and/or radiation toxicities to the eyes and brain. PMID:20166402

  17. Phase 1 Trial of Everolimus and Radiation Therapy for Salvage Treatment of Biochemical Recurrence in Prostate Cancer Patients Following Prostatectomy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Narayan, Vivek; Abramson Cancer Center, University of Pennsylvania, Philadelphia, Pennsylvania; Vapiwala, Neha

    Purpose: In up to half of patients treated with salvage radiation therapy (SRT) for rising prostate-specific antigen levels, a second biochemical recurrence ultimately develops. Phosphatase and tensin homolog inactivation is implicated in prostate cancer progression, and upregulation of the mammalian target of rapamycin pathway can lead to tumor hypoxia and radioresistance. Everolimus is a mammalian target of rapamycin inhibitor with both antitumor and radiosensitizing effects. Methods and Materials: We performed a phase 1 study using a modified 3 + 3 dose-escalation design to evaluate the safety and tolerability of everolimus in combination with standard SRT for the treatment of biochemical recurrence following prostatectomy. Aftermore » a 2-week run-in period of everolimus daily therapy, patients received prostate bed irradiation with daily cone beam computed tomography localization in 37 fractions of 1.8 Gy each (total dose, 66.6 Gy). Patients were monitored for both acute (≤90 days) and chronic (>90 days) treatment-related toxicities. Results: Eighteen patients received everolimus at dose levels of 5 mg (n=6), 7.5 mg (n=6), or 10 mg (n=6) daily in conjunction with SRT. No dose-limiting toxicities were observed. Common acute treatment-related toxicities included grade 1 or 2 mucositis (55.6%), grade 1 or 2 fatigue (38.9%), grade 1 or 2 rash (61.1%), and grade 1 urinary symptoms (61.1%). A grade 3 acute toxicity occurred in 4 patients (22.2%) (n=1 for rash, anemia, lymphopenia, and neutropenia), and no patients had a chronic toxicity of grade 3 or greater. After a median follow-up time of 17.8 months (range, 1.2-46.0 months), an undetectable prostate-specific antigen nadir was achieved in 9 patients (56.3%) and a second biochemical recurrence developed in 5 patients (31.3%). Conclusions: Everolimus at a dose of ≤10 mg daily appears to be safe and tolerable in combination with fractionated post-prostatectomy radiation therapy.« less

  18. Phase 1 Trial of Everolimus and Radiation Therapy for Salvage Treatment of Biochemical Recurrence in Prostate Cancer Patients Following Prostatectomy.

    PubMed

    Narayan, Vivek; Vapiwala, Neha; Mick, Rosemarie; Subramanian, Pearl; Christodouleas, John P; Bekelman, Justin E; Deville, Curtiland; Rajendran, Ramji; Haas, Naomi B

    2017-02-01

    In up to half of patients treated with salvage radiation therapy (SRT) for rising prostate-specific antigen levels, a second biochemical recurrence ultimately develops. Phosphatase and tensin homolog inactivation is implicated in prostate cancer progression, and upregulation of the mammalian target of rapamycin pathway can lead to tumor hypoxia and radioresistance. Everolimus is a mammalian target of rapamycin inhibitor with both antitumor and radiosensitizing effects. We performed a phase 1 study using a modified 3 + 3 dose-escalation design to evaluate the safety and tolerability of everolimus in combination with standard SRT for the treatment of biochemical recurrence following prostatectomy. After a 2-week run-in period of everolimus daily therapy, patients received prostate bed irradiation with daily cone beam computed tomography localization in 37 fractions of 1.8 Gy each (total dose, 66.6 Gy). Patients were monitored for both acute (≤90 days) and chronic (>90 days) treatment-related toxicities. Eighteen patients received everolimus at dose levels of 5 mg (n=6), 7.5 mg (n=6), or 10 mg (n=6) daily in conjunction with SRT. No dose-limiting toxicities were observed. Common acute treatment-related toxicities included grade 1 or 2 mucositis (55.6%), grade 1 or 2 fatigue (38.9%), grade 1 or 2 rash (61.1%), and grade 1 urinary symptoms (61.1%). A grade 3 acute toxicity occurred in 4 patients (22.2%) (n=1 for rash, anemia, lymphopenia, and neutropenia), and no patients had a chronic toxicity of grade 3 or greater. After a median follow-up time of 17.8 months (range, 1.2-46.0 months), an undetectable prostate-specific antigen nadir was achieved in 9 patients (56.3%) and a second biochemical recurrence developed in 5 patients (31.3%). Everolimus at a dose of ≤10 mg daily appears to be safe and tolerable in combination with fractionated post-prostatectomy radiation therapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. SU-F-T-147: An Alternative Parameterization of Scatter Behavior Allows Significant Reduction of Beam Characterization for Pencil Beam Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van den Heuvel, F; Fiorini, F; George, B

    2016-06-15

    Purpose: 1) To describe the characteristics of pencil beam proton dose deposition kernels in a homogenous medium using a novel parameterization. 2) To propose a method utilizing this novel parametrization to reduce the measurements and pre-computation required in commissioning a pencil beam proton therapy system. Methods: Using beam data from a clinical, pencil beam proton therapy center, Monte Carlo simulations were performed to characterize the dose depositions at a range of energies from 100.32 to 226.08 MeV in 3.6MeV steps. At each energy, the beam is defined at the surface of the phantom by a two-dimensional Normal distribution. Using FLUKA,more » the in-medium dose distribution is calculated in 200×200×350 mm cube with 1 mm{sup 3} tally volumes. The calculated dose distribution in each 200×200 slice perpendicular to the beam axis is then characterized using a symmetric alpha-stable distribution centered on the beam axis. This results in two parameters, α and γ, that completely describe shape of the distribution. In addition, the total dose deposited on each slice is calculated. The alpha-stable parameters are plotted as function of the depth in-medium, providing a representation of dose deposition along the pencil beam. We observed that these graphs are isometric through a scaling of both abscissa and ordinate map the curves. Results: Using interpolation of the scaling factors of two source curves representative of different beam energies, we predicted the parameters of a third curve at an intermediate energy. The errors are quantified by the maximal difference and provide a fit better than previous methods. The maximal energy difference between the source curves generating identical curves was 21.14MeV. Conclusion: We have introduced a novel method to parameterize the in-phantom properties of pencil beam proton dose depositions. For the case of the Knoxville IBA system, no more than nine pencil beams have to be fully characterized.« less

  20. Comparison of Planning Quality and Efficiency Between Conventional and Knowledge-based Algorithms in Nasopharyngeal Cancer Patients Using Intensity Modulated Radiation Therapy.

    PubMed

    Chang, Amy T Y; Hung, Albert W M; Cheung, Fion W K; Lee, Michael C H; Chan, Oscar S H; Philips, Helen; Cheng, Yung-Tang; Ng, Wai-Tong

    2016-07-01

    Intensity modulated radiation therapy (IMRT) is widely used to achieve a highly conformal dose and improve treatment outcome. However, plan quality and planning time are institute and planner dependent, and no standardized tool exists to recognize an optimal plan. RapidPlan, a knowledge-based algorithm, can generate constraints to assist optimization and produce high-quality IMRT plans. This report evaluated the quality and efficiency of using RapidPlan in nasopharyngeal carcinoma (NPC) IMRT planning. RapidPlan was configured using 79 radical IMRT plans for NPC; 20 consecutive NPC patients indicated for radical radiation therapy between October 2014 and May 2015 were then recruited to assess its performance. The ability of RapidPlan to produce acceptable plans was evaluated. For plans that could not achieve clinical acceptance, manual touch-up was performed. The IMRT plans produced without RapidPlan (manual plans) and with RapidPlan (RP-2 plans, including those with manual touch-up) were compared in terms of dosimetric quality and planning efficiency. RapidPlan by itself could produce clinically acceptable plans for 9 of the 20 patients; manual touch-up increased the number of acceptable plans (RP-2 plans) to 19. The target dose coverage and conformity were very similar. No difference was found in the maximum dose to the brainstem and optic chiasm. RP-2 plans delivered a higher maximum dose to the spinal cord (46.4 Gy vs 43.9 Gy, P=.002) but a lower dose to the parotid (mean dose to right parotid, 37.3 Gy vs 45.4 Gy; left, 34.4 Gy vs 43.1 Gy; P<.001) and the right cochlea (mean dose, 48.6 Gy vs 52.6 Gy; P=.02). The total planning time for RP-2 plans was significantly less than that for manual plans (64 minutes vs 295 minutes, P<.001). This study shows that RapidPlan can significantly improve planning efficiency and produce quality IMRT plans for NPC patients. Copyright © 2016 Elsevier Inc. All rights reserved.

Top