ERIC Educational Resources Information Center
Forsyth Technical Inst., Winston-Salem, NC.
This vocational physics individualized student instructional module on thermometers consists of the three units: Temperature and heat, expansion thermometers, and electrical thermometers. Designed with a laboratory orientation, experiments are included on linear expansion; making a bimetallic thermometer, a liquid-in-gas thermometer, and a gas…
Germanium resistance thermometer calibration at superfluid helium temperatures
NASA Technical Reports Server (NTRS)
Mason, F. C.
1985-01-01
The rapid increase in resistance of high purity semi-conducting germanium with decreasing temperature in the superfluid helium range of temperatures makes this material highly adaptable as a very sensitive thermometer. Also, a germanium thermometer exhibits a highly reproducible resistance versus temperature characteristic curve upon cycling between liquid helium temperatures and room temperature. These two factors combine to make germanium thermometers ideally suited for measuring temperatures in many cryogenic studies at superfluid helium temperatures. One disadvantage, however, is the relatively high cost of calibrated germanium thermometers. In space helium cryogenic systems, many such thermometers are often required, leading to a high cost for calibrated thermometers. The construction of a thermometer calibration cryostat and probe which will allow for calibrating six germanium thermometers at one time, thus effecting substantial savings in the purchase of thermometers is considered.
Gamma thermometer based reactor core liquid level detector
Burns, Thomas J.
1983-01-01
A system is provided which employs a modified gamma thermometer for determining the liquid coolant level within a nuclear reactor core. The gamma thermometer which normally is employed to monitor local core heat generation rate (reactor power), is modified by thermocouple junctions and leads to obtain an unambiguous indication of the presence or absence of coolant liquid at the gamma thermometer location. A signal processor generates a signal based on the thermometer surface heat transfer coefficient by comparing the signals from the thermocouples at the thermometer location. The generated signal is a direct indication of loss of coolant due to the change in surface heat transfer when coolant liquid drops below the thermometer location. The loss of coolant indication is independent of reactor power at the thermometer location. Further, the same thermometer may still be used for the normal power monitoring function.
Homemade thermometry instruments in the field.
Pasquier, Mathieu; Rousson, Valentin; Zen Ruffinen, Grégoire; Hugli, Olivier
2012-03-01
Esophageal temperature is the gold standard for in-the-field temperature monitoring in hypothermic victims with cardiac arrest. For practical reasons, some mountain rescue teams use homemade esophageal thermometers to measure esophageal temperature; these consist of nonmedical inside/outside temperature monitoring instruments that have been modified to allow for esophageal insertion. We planned a study to determine the accuracy of such thermometers. Two of the same model of digital cabled indoor/outdoor thermometer were modified and tested in comparison with a reference thermometer. The thermometers were tested in a water bath at different temperatures between 10°C and 35.2°C. Three hundred measurements were taken with each thermometer. Our experimental study showed that both homemade thermometers provided a good correlation and a clinically acceptable agreement in comparison with the reference thermometer. Measurements were within 0.5°C in comparison with the reference thermometer 97.5% of the time. The homemade thermometers performed well in vitro, in comparison with a reference thermometer. However, because these devices in their original form are not designed for clinical use, their use should be restricted to situations when the use of a conventional esophageal thermometer is impossible. Copyright © 2012 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.
[An ear thermometer based on infrared thermopiles sensor].
Xie, Haiyuan; Qian, Mingli
2013-09-01
According to the development of body temperature measurement mode, an ear thermometer with infrared thermopiles sensor is designed for body thermometry Compared with oral thermometer, the accuracy of ear thermometer is acceptable.
[The tympanic thermometer in pediatrics as an alternative to the mercury-in-glass thermometer].
Vertedor-Hurtado, María Victoria; Padín-López, Susana; Carreira-Pastor, María José; López-Martínez, Julia María
2009-01-01
To determine the behavior of a new and smaller model of infrared thermometer cone and to assess whether it is an appropriate alternative to determine fever in children under 14-years-old. We performed a cross-sectional, descriptive study comparing the temperatures taken with a mercury thermometer with those taken by an infrared thermometer in children under 14-years-old. The researchers followed the manufacturer's instructions for use for each thermometer. The overall sample of 400 children was divided into two age groups. Group I consisted of children aged less than 2 years and group II of 2-14-years-old. In group I the rectal mercury thermometer was placed in the rectum for 3 minutes and the tympanic thermometer was used in rectal mode and placed in the right ear. In group II, the axillary mercury thermometer was placed for 8 minutes in the right axilla and the tympanic thermometer was used in the axillary mode. To analyze intraobserver bias, 50 patients were selected from the sample and their temperatures were simultaneously taken by two nurses from the team. The intraclass correlation coefficient (ICC) was used both to measure the reliability of the tympanic thermometer and to analyze intraobserver bias. Temperature measurements with both instruments showed an ICC of 0.91 (95% confidence interval [CI], 0.88-0.94) for group I and 0.90 (95% CI, 0.87-0.92) for group II. The reproducibility of the measurements taken by the two nurses in 50 patients showed an ICC of 0.97 (95% CI, 0.95-0.98) for the tympanic thermometer. The infrared thermometer is an appropriate device for rapidly measuring temperature in the emergency department. However, the measurements taken should be confirmed by another method when clinical decisions are based on temperature values.
Thermometer use among Mexican immigrant mothers in California.
Schwartz, N; Guendelman, S; English, P
1997-11-01
A community-based household survey was utilized to assess the relationship between thermometer use, home treatment and utilization of health care services. Using a cross-sectional design, the study surveyed 688 low income Mexican origin mothers of children between the ages of 8 and 16 months in San Diego County. Mothers were asked how they determine that their child has fever and how often they use a thermometer. Nearly 40% of low income Mexican mothers interviewed in San Diego county never used a thermometer for determining childhood fever. Approximately two-thirds (64.7%) relied either primarily or exclusively on embodied methods such as visual observation or touch to determine fever in their child. A multivariate logistic regression analysis determined that low education and a separated or divorced marital status decreased the odds of thermometer use, whereas regular contact with the health care system doubled the likelihood of thermometer use. Mothers who relied on embodied methods were more likely to use over-the-counter medications than those who relied on thermometers; however, no significant differences were found between groups using other methods of home treatment. Fever determination modalities can be used to screen for lack of access to care and to provide for other health care needs in a culturally appropriate manner. While clinicians' expectations may include parental experience with temperature taking, current pediatric literature questions the need for home-based thermometer use. Possible alternatives to the traditional rectal thermometer might include digital thermometers and color coded thermometer strips.
NIST-NRC Comparison of Total Immersion Liquid-in-Glass Thermometers
NASA Astrophysics Data System (ADS)
Hill, K. D.; Gee, D. J.; Cross, C. D.; Strouse, G. F.
2009-02-01
The use of liquid-in-glass (LIG) thermometers is described in many documentary standards in the fields of environmental testing, material testing, and material transfer. Many national metrology institutes, including the National Institute of Standards and Technology (NIST) and the National Research Council of Canada (NRC), list calibration services for these thermometers among the Calibration Measurement Capabilities of Appendix C of the BIPM Key Comparison Database. NIST and NRC arranged a bilateral comparison of a set of total-immersion ASTM-type LIG thermometers to validate their uncertainty claims. Two each of ASTM thermometer types 62C through 69C were calibrated at NIST and at NRC at four temperatures distributed over the range appropriate to each thermometer, in addition to the ice point. Collectively, the thermometers span a temperature range of - 38 °C to 305 °C. In total, 160 measurements (80 pairs) comprise the comparison data set. Pair-wise differences ( T NIST- T NRC) were formed for each thermometer at each temperature. For 8 of the 80 pairs (10 %), the differences exceed the k = 2 combined uncertainties. These results support the claimed capabilities of NIST and NRC for the calibration of LIG thermometers.
21 CFR 880.2920 - Clinical mercury thermometer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Clinical mercury thermometer. 880.2920 Section 880... Devices § 880.2920 Clinical mercury thermometer. (a) Identification. A clinical mercury thermometer is a... mercury. (b) Classification. Class II (special controls). The device is exempt from the premarket...
21 CFR 880.2920 - Clinical mercury thermometer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Clinical mercury thermometer. 880.2920 Section 880... Devices § 880.2920 Clinical mercury thermometer. (a) Identification. A clinical mercury thermometer is a... mercury. (b) Classification. Class II (special controls). The device is exempt from the premarket...
21 CFR 880.2920 - Clinical mercury thermometer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Clinical mercury thermometer. 880.2920 Section 880... Devices § 880.2920 Clinical mercury thermometer. (a) Identification. A clinical mercury thermometer is a... mercury. (b) Classification. Class II (special controls). The device is exempt from the premarket...
21 CFR 880.2920 - Clinical mercury thermometer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Clinical mercury thermometer. 880.2920 Section 880... Devices § 880.2920 Clinical mercury thermometer. (a) Identification. A clinical mercury thermometer is a... mercury. (b) Classification. Class II (special controls). The device is exempt from the premarket...
NASA Astrophysics Data System (ADS)
Spietz, Lafe Frederick
This thesis describes the development and testing of the shot noise thermometer, or SNT, a new kind of noise thermometer based on the combined thermal and shot noise of a tunnel junction in the non-superconducting state. In the shot noise thermometer, the noise power from a tunnel junction is measured as a function of the DC voltage across the junction, and the temperature is determined from the voltage dependence of the noise. This voltage dependence follows directly from the Fermi statistics of electrons in a metal, and is independent of the gain or noise temperature of the microwave amplifiers and detector used to measure the noise. Since the shot noise thermometer requires no calibration from an external temperature standard, it is a primary thermometer. In this thesis I demonstrate the operation of the shot noise thermometer over four orders of magnitude in temperature, from the base temperature of a dilution refrigerator to room temperature. Because of its wide range and the fact that it requires no outside calibration (it is a primary thermometer), the SNT is useful as a thermometer for general use in dilution refrigerators. In addition, the shot noise thermometer has sufficient accuracy to be useful as a potential temperature standard. This thesis discusses both of these applications as well as basic physics questions about the operation of the SNT and prospects for future development of the SNT technology.
Mercury Thermometer Replacements in Chemistry Laboratories
ERIC Educational Resources Information Center
Foster, Barbara L.
2005-01-01
The consequences of broken mercury-in-glass thermometers in academic laboratories results in various health and environmental hazards, which needs to be replaced, by long-stem digital thermometers and non-mercury glass thermometers. The factors that should be considered during the mercury replacement process are types of applications in the…
21 CFR 880.2920 - Clinical mercury thermometer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clinical mercury thermometer. 880.2920 Section 880.2920 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.2920 Clinical mercury thermometer. (a) Identification. A clinical mercury thermometer is a...
A Non-Mercury Thermometer Alternative for Use in Older Melting Point Apparatuses
ERIC Educational Resources Information Center
Ongley, Lois K.; Kern, Clayton S.; Woods, Barry W.
2008-01-01
The State of Maine seeks to eliminate most mercury use. This includes removing mercury thermometers from secondary schools and discouraging Hg use in other educational institutions. Alternatives to mercury thermometers in chemical laboratory work include non-mercury thermometers, temperature probes, and thermocouples. In organic chemistry mercury…
A Miniature Palladium-Iron Thermometer for Temperatures Down to 0.05 K
NASA Technical Reports Server (NTRS)
Tuttle, Jim; DiPirro, Michael; Canavan, Ed; Shirron, Peter; Kunes, Evan; Hait, Tom; Krebs, Carolyn (Technical Monitor)
2001-01-01
Magnetic thermometers are appealing at temperatures below about 0.1 Kelvin, because the avoid the noise self-heating problems associated with resistive thermometers. In practical, metallic dilute electronic thermometers add the advantages of chemical stability, high thermal conductivity, and easy in heat sinking work we describe a palladium-iron thermometer which was designed to be small and conveniently packaged and optimized for use at temperatures down to 0.05 Kelvin. The device showed Curie-Weiss behavior above about 0.06 Kelvin, and we achieve 41 nK/ square root of z temperature resolution at a temperature of 49 mK. We describe the design and operation of this thermometers and present the test results.
Comparative Study of Two InGaAs-Based Reference Radiation Thermometers
NASA Astrophysics Data System (ADS)
Nasibov, H.; Diril, A.; Pehlivan, O.; Kalemci, M.
2017-07-01
More than one decade ago, an InGaAs detector-based transfer standard infrared radiation thermometer working in the temperature range from 150 {^{circ }}\\hbox {C} to 1100 {^{circ }}\\hbox {C} was built at TUBITAK UME in the scope of collaboration with IMGC (INRIM since 2006). During this timescale, the radiation thermometer was used for the dissemination of the radiation temperature scale below the silver fixed-point temperature. Recently, a new radiation thermometer with the same design but with different spectral responsivity was constructed and employed in the laboratory. In this work, we present the comparative study of these thermometers. Furthermore, the paper describes the measurement results of the thermometer's main characteristics such as the size-of-source effect, spectral responsivity, gain ratio, and linearity. Besides, both thermometers were calibrated at the freezing temperatures of indium, tin, zinc, aluminum, and copper reference fixed-point blackbodies. The main study is focused on the impact of the spectral responsivity of thermometers on the interpolation parameters of the Sakuma-Hattori equation. Furthermore, the calibration results and the uncertainty sources are discussed in this paper.
A new cryogenic diode thermometer
NASA Astrophysics Data System (ADS)
Courts, S. S.; Swinehart, P. R.; Yeager, C. J.
2002-05-01
While the introduction of yet another cryogenic diode thermometer is not earth shattering, a new diode thermometer, the DT-600 series, recently introduced by Lake Shore Cryotronics, possesses three features that make it unique among commercial diode thermometers. First, these diodes have been probed at the chip level, allowing for the availability of a bare chip thermometer matching a standard curve-an important feature in situations where real estate is at a premium (IR detectors), or where in-situ calibration is difficult. Second, the thermometry industry has assumed that interchangeability should be best at low temperatures. Thus, good interchangeability at room temperatures implies a very good interchangeability at cryogenic temperature, resulting in a premium priced sensor. The DT-600 series diode thermometer is available in an interchangeability band comparable to platinum RTDs with the added advantage of interchangeability to 2 K. Third, and most important, the DT-600 series diode does not exhibit an instability in the I-V characteristic in the 8 K to 20 K temperature range that is observed in other commercial diode thermometer devices [1]. This paper presents performance characteristics for the DT-600 series diode thermometer along with a comparison of I-V curves for this device and other commercial diode thermometers exhibiting an I-V instability.
Lunney, Meaghan; Tonelli, Bronwyn; Lewis, Rachel; Wiebe, Natasha; Thomas, Chandra; MacRae, Jennifer; Tonelli, Marcello
2018-06-14
Thermometers that measure core (internal) body temperature are the gold standard for monitoring temperature. Despite that most modern hemodialysis machines are equipped with an internal blood monitor that measures core body temperature, current practice is to use peripheral thermometers. A better understanding of how peripheral thermometers compare with the dialysis machine thermometer may help guide practice. The study followed a prospective cross-sectional design. Hemodialysis patients were recruited from 2 sites in Calgary, Alberta (April - June 2017). Body temperatures were obtained from peripheral (temporal artery) and dialysis machine thermometers concurrently. Paired t-tests, Bland-Altman plots, and quantile-quantile plots were used to compare measurements from the two devices and to explore potential factors affecting temperature in hemodialysis patients. The mean body temperature of 94 hemodialysis patients measured using the temporal artery thermometer (36.7 °C) was significantly different than the dialysis machine thermometer (36.4 °C); p < 0.001. The mean difference (0.27 °C) appeared to be consistent across average temperature (range: 35.8-37.3 °C). Temperature measured by the temporal artery thermometer was statistically and clinically higher than that measured by the dialysis machine thermometer. Using the dialysis machine to monitor body temperature may result in more accurate readings and is likely to reduce the purchasing and maintenance costs associated with manual temperature readings, as well as easing the workload for dialysis staff.
Debnath, Tridib; Bera, Santanu; Deb, Suman; Pal, Prasenjit; Debbarma, Nibash; Haldar, Avijit
2017-01-01
Aim: Dairy cattle health monitoring program becomes vital for detecting the febrile conditions to prevent the outbreak of the animal diseases as well as ensuring the fitness of the animals that are directly affecting the health of the consumers. The aim of this study was to validate real-time rectal temperature (RT) data of radio frequency based digital (RFD) thermometer with RT data of mercury bulb (MB) thermometer in dairy cattle. Materials and Methods: Two experiments were conducted. In experiment I, six female Jersey crossbred cattle with a mean (±standard error of the mean) body weight of 534.83±13.90 kg at the age of 12±0.52 years were used to record RT for 2 h on empty stomach and 2 h after feeding at 0, 30, 60, 90, and 120 min using a RFD thermometer as well as a MB thermometer. In experiment II, six female Jersey crossbred cattle were further used to record RT for 2 h before exercise and 2 h after exercise at 0, 30, 60, 90, and 120 min. Two-way repeated measures analysis of variance with post hoc comparisons by Bonferroni test was done. Results: Real-time RT data recorded by RFD thermometer as well as MB thermometer did not differ (p>0.05) before and after feeding/exercise. An increase (p<0.05) in RT after feeding/exercise in experimental crossbred cattle was recorded by both RFD thermometer and MB thermometer. Conclusion: The results obtained in the present study suggest that the body temperature recordings from RFD thermometer would be acceptable and thus RFD thermometer could work well for monitoring real-time RT in cattle. PMID:29062193
Apa, Hurşit; Gözmen, Salih; Bayram, Nuri; Çatkoğlu, Asl; Devrim, Fatma; Karaarslan, Utku; Günay, İlker; Ünal, Nurettin; Devrim, İlker
2013-09-01
The aim of this study was to compare the body temperature measurements of infrared tympanic and forehead noncontact thermometers with the axillary digital thermometer. Randomly selected 50 pediatric patients who were hospitalized in Dr Behcet Uz Children's Training and Research Hospital, Pediatric Infectious Disease Unit, between March 2012 and September 2012 were included in the study. Body temperature measurements were performed using an axillary thermometer (Microlife MT 3001), a tympanic thermometer (Microlife Ear Thermometer IR 100), and a noncontact thermometer (ThermoFlash LX-26). Fifty patients participated in this study. We performed 1639 temperature readings for every method. The average difference between the mean (SD) of both axillary and tympanic temperatures was -0.20°C (0.61°C) (95% confidence interval, -1.41°C to 1.00°C). The average difference between the mean (SD) of both axillary and forehead temperatures was -0.38 (0.55°C) (95% confidence interval, -1.47°C to 0.70°C). The Bland-Altman plot showed that most of the data points were tightly clustered around the zero line of the difference between the 2 temperature readings. With the use of the axillary method as the criterion standard, positive likelihood ratios were 17.9 and 16.5 and negative likelihood ratios were 0.2 and 0.4 for tympanic and forehead measurements, respectively. The results demonstrated that the infrared tympanic thermometer could be a good option in the measurement of fever in the pediatric population. The noncontact infrared thermometer is very useful for the screening of fever in the pediatric population, but it must be used with caution because it has a high value of bias.
Debnath, Tridib; Bera, Santanu; Deb, Suman; Pal, Prasenjit; Debbarma, Nibash; Haldar, Avijit
2017-09-01
Dairy cattle health monitoring program becomes vital for detecting the febrile conditions to prevent the outbreak of the animal diseases as well as ensuring the fitness of the animals that are directly affecting the health of the consumers. The aim of this study was to validate real-time rectal temperature (RT) data of radio frequency based digital (RFD) thermometer with RT data of mercury bulb (MB) thermometer in dairy cattle. Two experiments were conducted. In experiment I, six female Jersey crossbred cattle with a mean (±standard error of the mean) body weight of 534.83±13.90 kg at the age of 12±0.52 years were used to record RT for 2 h on empty stomach and 2 h after feeding at 0, 30, 60, 90, and 120 min using a RFD thermometer as well as a MB thermometer. In experiment II, six female Jersey crossbred cattle were further used to record RT for 2 h before exercise and 2 h after exercise at 0, 30, 60, 90, and 120 min. Two-way repeated measures analysis of variance with post hoc comparisons by Bonferroni test was done. Real-time RT data recorded by RFD thermometer as well as MB thermometer did not differ (p>0.05) before and after feeding/exercise. An increase (p<0.05) in RT after feeding/exercise in experimental crossbred cattle was recorded by both RFD thermometer and MB thermometer. The results obtained in the present study suggest that the body temperature recordings from RFD thermometer would be acceptable and thus RFD thermometer could work well for monitoring real-time RT in cattle.
... Administrative Forms Standard Forms Skip Navigation Z7_0Q0619C0JGR010IFST1G5B10H1 Web Content Viewer (JSR 286) Actions ${title} Loading... / Topics / ... and Thermometers / Kitchen Thermometers / Kitchen Thermometers Z7_0Q0619C0JGR010IFST1G5B10H3 Web Content Viewer (JSR 286) Actions ${title} Loading... Z7_ ...
Thermometers: Understand the Options
... the options Thermometers come in a variety of styles. Understand the different types of thermometers and how ... MA. Fever in infants and children: Pathophysiology and management. http://www.uptodate.com/home. Accessed July 23, ...
Accuracy of tympanic and infrared skin thermometers in children.
Paes, B F; Vermeulen, K; Brohet, R M; van der Ploeg, T; de Winter, J P
2010-12-01
Rectal measurement is considered a gold standard in many healthcare systems for body temperature measurement in children. Although this method has several disadvantages, an ideal alternative thermometer has not yet been introduced. However tympanic and infrared skin thermometers are potential alternatives. A prospective cohort study was performed including 100 children between 0 and 18 years of age admitted to the general paediatric ward of Spaarne Hospital in The Netherlands between January and March 2009. The objectives of this study are to evaluate the accuracy of tympanic and two types of infrared skin thermometers (Beurer and Thermofocus) compared to rectal measurement and furthermore to evaluate the influence of different variables on temperature measurements. Compared to rectal measurement (37.56°C), the mean temperatures of the tympanic (37.29°C), Beurer (36.79°C) and Thermofocus (37.30°C) thermometers differed significantly (p<0.001). Mean and SD of differences between rectal temperature and temperature measured with these alternative devices varied significantly (p<0.001). Sensitivity, specificity, positive and negative predictive values for detecting rectal fever measured with the tympanic, Beurer and Thermofocus thermometers are unacceptable, especially for the Beurer thermometer. This difference in temperature between rectal and the alternative thermometers remained after stratification on gender, age, skin colour and otoscopic abnormalities. In this study the authors demonstrated that the tympanic, Beurer and Thermofocus thermometers cannot reliably predict rectal temperature. Therefore the authors do not advise replacement of rectal measurement as the gold standard for detecting fever in children by one of these devices. When rectal measurement is not used, the infrared skin thermometers appear to perform less well than tympanic measurements.
Hernandez, Jose; Nicholson, Brian D; Thompson, Matthew
2015-06-01
Thermometers are found in most parents' homes, but little is known about the quality and accuracy of the information they provide, nor its consistency with current guidelines for managing fever. To compare information included with commonly available thermometers with National Institute for Health and Care Excellence (NICE) guidance for management of feverish illness in children. Systematic thermometer sampling from UK retailers between February 2013 and May 2013. Information was extracted from device packaging and leaflets on details and type of thermometer, instructions for use, normal ranges, and fever thresholds cited. This was compared with key parental recommendations from the 2013 NICE guidance on feverish illness in children. Associations were explored between cost of device and level of information. There were 123 thermometers identified (ranging from £0.99 to £69.99), none of which made explicit reference to NICE guidance. Most (n = 81, 65.9%) recommended use at a body site consistent with NICE guidance, but only 17 (13.8%) defined fever using the correct threshold (≥38.0°C), and few (n = 12, 9.8%) included advice on fever management, of which four suggested actions not advised by NICE. There was no association between thermometer cost and provision of information consistent with NICE guidance. Parents and caregivers have access to a large number of thermometers, yet they lack evidence-based information about fever detection and management, and in some cases contain misleading information. This represents a missed opportunity to disseminate best practices from guidelines for management of fever in children, and thermometer manufacturers are urged to include information consistent with current guidance. © British Journal of General Practice 2015.
NASA Astrophysics Data System (ADS)
Bussweiler, Y.; Brey, G. P.; Pearson, D. G.; Stachel, T.; Stern, R. A.; Hardman, M. F.; Kjarsgaard, B. A.; Jackson, S. E.
2017-02-01
This study provides an experimental calibration of the empirical Al-in-olivine thermometer for mantle peridotites proposed by De Hoog et al. (2010). We report Al concentrations measured by secondary ion mass spectrometry (SIMS) in olivines produced in the original high-pressure, high-temperature, four-phase lherzolite experiments by Brey et al. (1990). These reversed experiments were used for the calibration of the two-pyroxene thermometer and Al-in-orthopyroxene barometer by Brey and Köhler (1990). The experimental conditions of the runs investigated here range from 28 to 60 kbar and 1000 to 1300 °C. Olivine compositions from this range of experiments have Al concentrations that are consistent, within analytical uncertainties, with those predicted by the empirical calibration of the Al-in-olivine thermometer for mantle peridotites. Fitting the experimental data to a thermometer equation, using the least squares method, results in the expression: This version of the Al-in-olivine thermometer appears to be applicable to garnet peridotites (lherzolites and harzburgites) well outside the range of experimental conditions investigated here. However, the thermometer is not applicable to spinel-bearing peridotites. We provide new trace element criteria to distinguish between olivine from garnet-, garnet-spinel-, and spinel-facies peridotites. The estimated accuracy of the thermometer is ± 20 °C. Thus, the thermometer could serve as a useful tool in settings where two-pyroxene thermometry cannot be applied, such as garnet harzburgites and single inclusions in diamond.
Usability evaluation of the digital anger thermometer app.
Mattson, Donald C
2017-09-01
The digital anger thermometer is a prototype for a mobile application (app) for use with adults in anger management treatment. The digital anger thermometer incorporates standards of software development in addition to anger management resources from the Substance Abuse and Mental Health Services Administration. The digital anger thermometer underwent a usability study conducted by five expert reviewers. The results indicate that it is easy to learn, efficient, and ergonomically sound. However, it does not offer support features or user-error tolerance. The digital anger thermometer prototype requires additional usability studies and comparative research in order for it to become an actual mental health app.
Introducing Temperature Scales.
ERIC Educational Resources Information Center
McIldowie, Eric
1998-01-01
Ignoring the interpretive problems of temperature measurement deprives students of a beneficial, positive educational experience. Suggests experimenting with different thermometers including a copper resistance thermometer, a thermistor, a thermocouple, and a constant-volume air thermometer. Provides guidance for the classroom discussion of…
ERIC Educational Resources Information Center
Edwards, Zena; Edlefsen, Miriam; Hillers, Virginia; McCurdy, Sandra M.
2005-01-01
The U.S. Dept. of Agriculture recommends use of food thermometers to safely cook small cuts of meat, yet most consumers do not use them. Consumers lack knowledge about how and why to use food thermometers with small cuts of meat. Opportunities exist for family and consumer science classes to provide education about thermometers to adolescents, who…
JPRS Report Science & Technology Japan Status, Future Trends in Sensor Technology.
1989-10-27
thermometer Temperature-sensing reed switch NQR thermometer Thermal noise thermometer Radiation thermometer (1) Thermoelectric Effect When one...The Temperature Characteristics of NQR [nuclear quadpol resonance] This is something that utilizes the effect by which the resonance absorption...advance there will be no need for revision. The temperature-dependence of the NQR frequency is shown in Figure 1. o c 0) 3 O" <u M 4-1 29.0
A comparison of technologies used for estimation of body temperature.
Mangat, Jasdip; Standley, Thomas; Prevost, Andrew; Vasconcelos, Joana; White, Paul
2010-09-01
Body temperature measurement is an important clinical parameter. The performance of a number of non-invasive thermometers was measured by comparing intra- and inter-operator variability (n = 100) and clinical accuracy (n = 61). Variability was elevated in febrile compared to normothermic subjects for axillary and oral electronic contact thermometer measures and a temporal artery thermometer (p < 0.001 for both). Temporal artery thermometry and one mode of an infrared tympanic thermometer demonstrated significant clinical inaccuracy (p < 0.001 for both). Electronic contact thermometer repeatability and reproducibility are highly variable in febrile adults both in the axilla and oral cavity. Infrared thermometry of the skin over the superficial temporal artery is unreliable for measuring core body temperature, particularly in febrile subjects and patients in theatre. The infrared tympanic thermometers tested are acceptable for clinical practice; however, care should be exercised with the different modes of operation offered.
Rubia-Rubia, J; Arias, A; Sierra, A; Aguirre-Jaime, A
2011-07-01
We compared a range of alternative devices with core body temperature measured at the pulmonary artery to identify the most valid and reliable instrument for measuring temperature in routine conditions in health services. 201 patients from the intensive care unit of the Candelaria University Hospital, Canary Islands, admitted to hospital between April 2006 and July 2007. All patients (or their families) gave informed consent. Readings from gallium-in-glass, reactive strip and digital in axilla, infra-red ear and frontal thermometers were compared with the pulmonary artery core temperature simultaneously. External factors suspected of having an influence on the differences were explored. The cut-off point readings for each thermometer were fixed for the maximum negative predictive value in comparison with the core temperature. The validity, reliability, accuracy, external influence, the waste they generated, ease of use, speed, durability, security, comfort and cost of each thermometer was evaluated. An ad hoc overall valuation score was obtained from these parameters for each instrument. For an error of ± 0.2°C and concordance with respect to fever, the gallium-in-glass thermometer gave the best results. The largest area under the receiver operating characteristic (ROC) curve is obtained by the digital axillar thermometer with probe (0.988 ± 0.007). The minimum difference between readings was given by the infrared ear thermometer, in comparison with the core temperature (-0.1 ± 0.3°C). Age, weight, level of conscience, male sex, environmental temperature and vaso-constrictor medication increases the difference in the readings and fever treatment reduces it, although this is not the same for all thermometers. The compact digital axillar thermometer and the digital thermometer with probe obtained the highest overall valuation score. If we only evaluate the aspects of validity, reliability, accuracy and external influence, the best thermometer would be the gallium-in-glass after 12 min. The gallium-in-glass thermometer is less accurate after only 5 min in comparison with the reading taken after being placed for 12 min. If we add the evaluation of waste production, ease-of-use, speed, durability, security, patient comfort and costs, the thermometers that obtain the highest score are the compact digital and digital with probe in right axilla. Copyright © 2010 Elsevier Ltd. All rights reserved.
Koster, Glen Peter; Xia, Hua; Lee, Boon Kwee
2013-08-06
An optical gamma thermometer includes a metal mass having a temperature proportional to a gamma flux within a core of a nuclear reactor, and an optical fiber cable for measuring the temperature of the heated metal mass. The temperature of the heated mass may be measured by using one or more fiber grating structures and/or by using scattering techniques, such as Raman, Brillouin, and the like. The optical gamma thermometer may be used in conjunction with a conventional reactor heat balance to calibrate the local power range monitors over their useful in-service life. The optical gamma thermometer occupies much less space within the in-core instrument tube and costs much less than the conventional gamma thermometer.
About thermometers and temperature
NASA Astrophysics Data System (ADS)
Baldovin, M.; Puglisi, A.; Sarracino, A.; Vulpiani, A.
2017-11-01
We discuss a class of mechanical models of thermometers and their minimal requirements to determine the temperature for systems out of the common scope of thermometry. In particular we consider: (1) anharmonic chains with long time of thermalization, such as the Fermi-Pasta-Ulam (FPU) model; (2) systems with long-range interactions where the equivalence of ensembles does not always hold; (3) systems featuring absolute negative temperatures. We show that for all the three classes of systems a mechanical thermometer model can be designed: a temporal average of a suitable mechanical observable of the thermometer is sufficient to get an estimate of the system’s temperature. Several interesting lessons are learnt from our numerical study: (1) the long thermalization times in FPU-like systems do not affect the thermometer, which is not coupled to normal modes but to a group of microscopic degrees of freedom; (2) a thermometer coupled to a long-range system measures its microcanonical temperature, even at values of the total energy where its canonical temperature would be very different; (3) a thermometer to read absolute negative temperatures must have a bounded total energy (as the system), otherwise it heavily perturbs the system changing the sign of its temperature. Our study shows that in order to also work in a correct way in ‘non standard’ cases, the proper model of thermometer must have a special functional form, e.g. the kinetic part cannot be quadratic.
Gray-Winnett, Misty D; Davis, Courtney S; Yokley, Stephanie G; Franks, Andrea S
2010-01-01
To decrease the amount of pharmaceuticals present in our community's water supply, reduce the accidental and intentional ingestion of pharmaceuticals, and increase awareness of proper medication disposal. Knoxville, TN, from November 2008 to November 2009. Medication and thermometer collection events were held at various community retail establishments. Community officials and students collaborated to plan advertising, implementation, and appropriate medication and thermometer disposal. Event volunteers set up easily accessible tents and tables in high-traffic areas to collect unused medications, mercury thermometers, and recyclable medication bottles. Student pharmacists worked cooperatively with community partners to collect unused medications and exchange thermometers. Pounds of recyclables collected, pounds of medications collected, and number of thermometers exchanged. The events increased community awareness of appropriate medication disposal and pharmacists' roles in safe use of medications. From November 2008 to November 2009, more than 1,100 pounds of unwanted medications were collected through events and the drop box. Additionally, more than 470 pounds of recyclable packaging material was collected and 535 mercury thermometers exchanged. Student pharmacists can partner with community officials and businesses to provide safe and appropriate medication and mercury thermometer disposal.
Novel MEMS-based thermometer with low power consumption for health-monitoring network application
NASA Astrophysics Data System (ADS)
Zhang, Y.; Ikehara, T.; Lu, J.; Kobayashi, T.; Ichiki, M.; Itoh, T.; Maeda, R.
2007-12-01
We proposed one novel MEMS-based thermometer with low power-consumption for animal/human health-monitoring network application. The novel MEMS-based thermometer was consisted of triple-beam bimorph arrays so that it could work in a continuous temperature range. Neither continuous electric supply nor A/D converter interface is required by the novel thermometer owing to the well-known deflection of bimaterials cantilever upon temperature changes. The triple-beam structure also facilitated the novel thermometer with excellent fabrication feasibility by conventional microfabrication technology. The parameters of the triple-beam bimorph arrays were determined by finite element analysis with ANSYS program. Low stress Au and Mo metal films were used as top and bottom layer, respectively. The deflection of the triple-beam bimorphs were measured on a home-made heating stage by a confocal scanning laser microscopy. The novel bimorphs had temperature responses similar to traditional single-beam bimorphs. Initial bend of the prepared triple-beam bimorphs were dominantly determined by their side beams. The sensitivity of the novel thermometer was as high as 0.1°C. Experimental results showed that the novel thermometer is attractive for network sensing applications where the power capacity is limited.
21 CFR 880.2910 - Clinical electronic thermometer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clinical electronic thermometer. 880.2910 Section... Monitoring Devices § 880.2910 Clinical electronic thermometer. (a) Identification. A clinical electronic... with an electronic signal amplification, conditioning, and display unit. The transducer may be in a...
21 CFR 880.2910 - Clinical electronic thermometer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Clinical electronic thermometer. 880.2910 Section... Monitoring Devices § 880.2910 Clinical electronic thermometer. (a) Identification. A clinical electronic... with an electronic signal amplification, conditioning, and display unit. The transducer may be in a...
21 CFR 880.2910 - Clinical electronic thermometer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Clinical electronic thermometer. 880.2910 Section... Monitoring Devices § 880.2910 Clinical electronic thermometer. (a) Identification. A clinical electronic... with an electronic signal amplification, conditioning, and display unit. The transducer may be in a...
21 CFR 880.2910 - Clinical electronic thermometer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Clinical electronic thermometer. 880.2910 Section... Monitoring Devices § 880.2910 Clinical electronic thermometer. (a) Identification. A clinical electronic... with an electronic signal amplification, conditioning, and display unit. The transducer may be in a...
21 CFR 880.2910 - Clinical electronic thermometer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Clinical electronic thermometer. 880.2910 Section... Monitoring Devices § 880.2910 Clinical electronic thermometer. (a) Identification. A clinical electronic... with an electronic signal amplification, conditioning, and display unit. The transducer may be in a...
Greer, Rebecca J; Cohn, Leah A; Dodam, John R; Wagner-Mann, Colette C; Mann, F A
2007-06-15
To assess the reliability and accuracy of a predictive rectal thermometer, an infrared auricular thermometer designed for veterinary use, and a subcutaneous temperature-sensing microchip for measurement of core body temperature over various temperature conditions in dogs. Prospective study. 8 purpose-bred dogs. A minimum of 7 days prior to study commencement, a subcutaneous temperature-sensing microchip was implanted in 1 of 3 locations (interscapular, lateral aspect of shoulder, or sacral region) in each dog. For comparison with temperatures measured via rectal thermometer, infrared auricular thermometer, and microchip, core body temperature was measured via a thermistor-tipped pulmonary artery (TTPA) catheter. Hypothermia was induced during anesthesia at the time of TTPA catheter placement; on 3 occasions after placement of the catheter, hyperthermia was induced via administration of a low dose of endotoxin. Near-simultaneous duplicate temperature measurements were recorded from the TTPA catheter, the rectal thermometer, auricular thermometer, and subcutaneous microchips during hypothermia, euthermia, and hyperthermia. Reliability (variability) of temperature measurement for each device and agreement between each device measurement and core body temperature were assessed. Variability between duplicate near-simultaneous temperature measurements was greatest for the auricular thermometer and least for the TTPA catheter. Measurements obtained by use of the rectal thermometer were in closest agreement with core body temperature; for all other devices, temperature readings typically underestimated core body temperature. Among the 3 methods of temperature measurement, rectal thermometry provided the most accurate estimation of core body temperature in dogs.
27 CFR 30.23 - Use of precision hydrometers and thermometers.
Code of Federal Regulations, 2010 CFR
2010-04-01
... hydrometers and thermometers. 30.23 Section 30.23 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO... Use of precision hydrometers and thermometers. Care should be exercised to obtain accurate hydrometer... entire quantity. The hydrometers should be kept clean and free of any oily substance. Immediately before...
21 CFR 880.2900 - Clinical color change thermometer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clinical color change thermometer. 880.2900... Monitoring Devices § 880.2900 Clinical color change thermometer. (a) Identification. A clinical color change... end of a plastic or metal strip. Body heat causes a stable color change in the heat sensitive...
Chen, Patty H; White, Charles E
2006-01-01
This study compared rabbit rectal thermometry with 4 other thermometry techniques: an implantable microchip temperature transponder, an environmental noncontact infrared thermometer, a tympanic infrared thermometer designed for use on humans, and a tympanic infrared thermometer designed for use on animals. The microchip transponder was implanted between the shoulder blades; the environmental noncontact infrared thermometer recorded results from the base of the right pinna and the left inner thigh, and the tympanic infrared thermometer temperatures were taken from the right ear. Results from each technique were compared to determine agreement between the test modality and the rectal temperature. The practicality and reliability of the modalities were reviewed also. According to this study, the implantable microchip transponder measurements agreed most closely with the rectal temperature.
Measuring Systems for Thermometer Calibration in Low-Temperature Range
NASA Astrophysics Data System (ADS)
Szmyrka-Grzebyk, A.; Lipiński, L.; Manuszkiewicz, H.; Kowal, A.; Grykałowska, A.; Jancewicz, D.
2011-12-01
The national temperature standard for the low-temperature range between 13.8033 K and 273.16 K has been established in Poland at the Institute of Low Temperature and Structure Research (INTiBS). The standard consists of sealed cells for realization of six fixed points of the International Temperature Scale of 1990 (ITS-90) in the low-temperature range, an adiabatic cryostat and Isotech water and mercury triple-point baths, capsule standard resistance thermometers (CSPRT), and AC and DC bridges with standard resistors for thermometers resistance measurements. INTiBS calibrates CSPRTs at the low-temperature fixed points with uncertainties less than 1 mK. In lower temperature range—between 2.5 K and about 25 K — rhodium-iron (RhFe) resistance thermometers are calibrated by comparison with a standard which participated in the EURAMET.T-K1.1 comparison. INTiBS offers a calibration service for industrial platinum resistance thermometers and for digital thermometers between 77 K and 273 K. These types of thermometers may be calibrated at INTiBS also in a higher temperature range up to 550°C. The Laboratory of Temperature Standard at INTiBS acquired an accreditation from the Polish Centre for Accreditation. A management system according to EN ISO/IEC 17025:2005 was established at the Laboratory and presented on EURAMET QSM Forum.
Demonstrating the Temperature Dependence of Density via Construction of a Galilean Thermometer
ERIC Educational Resources Information Center
Priest, Marie A.; Padgett, Lea W.; Padgett, Clifford W.
2011-01-01
A method for the construction of a Galilean thermometer out of common chemistry glassware is described. Students in a first-semester physical chemistry (thermodynamics) class can construct the Galilean thermometer as an investigation of the thermal expansivity of liquids and the temperature dependence of density. This is an excellent first…
The Infrared Thermometer in School Science: Teaching Physics with Modern Technologies
ERIC Educational Resources Information Center
Girwidz, Raimund; Ireson, Gren
2011-01-01
Infrared thermometers measure temperature from a distance, using the infrared radiation emitted by all objects. These so-called non-contact thermometers make a wide variety of temperature measurement and monitoring activities accessible to school-age students. Portable hand-held sensors also enable new or simplified investigations to be carried…
Size-of-source Effect in Infrared Thermometers with Direct Reading of Temperature
NASA Astrophysics Data System (ADS)
Manoi, A.; Saunders, P.
2017-07-01
The size-of-source effect (SSE) for six infrared (IR) thermometers with direct reading of temperature was measured in this work. The alternative direct method for SSE determination, where the aperture size is fixed and the measurement distance is varied, was used in this study. The experimental equivalence between the usual and the alternative direct methods is presented. The magnitudes of the SSE for different types of IR thermometers were investigated. The maxima of the SSE were found to be up to 5 %, 8 %, and 28 % for focusable, closed-focus, and open-focus thermometers, respectively. At 275°C, an SSE of 28 % corresponds to 52°C, indicating the severe effect on the accuracy of this type of IR thermometer. A method to realize the calibration conditions used by the manufacturer, in terms of aperture size and measurement distance, is discussed and validated by experimental results. This study would be of benefit to users in choosing the best IR thermometer to match their work and for calibration laboratories in selecting the technique most suitable for determining the SSE.
A noise thermometry investigation of the melting point of gallium at the NIM
NASA Astrophysics Data System (ADS)
Zhang, J. T.; Xue, S.
2006-06-01
This paper describes a study of the melting point of gallium with the new NIM Johnson noise thermometer (JNT). The new thermometer adopts the structure of switching correlator and commutator with the reference resistor maintained at the triple point of water. The electronic system of the new thermometer is basically the same as the current JNT, but the preamplifiers have been improved slightly. This study demonstrates that examining the characteristics of the noise signals in the frequency domain is of critical importance in constructing an improved new thermometer, where a power spectral analysis is found to be critical in establishing appropriate grounding for the new thermometer. The new JNT is tested on measurements of the thermodynamic temperature of the melting point of gallium, which give the thermodynamic temperature of 302.9160 K, with an overall integration time of 190 h and a combined standard uncertainty of 9.4 mK. The uncertainty analysis indicates that a standard combined uncertainty of 3 mK could be achieved with the new thermometer over an integration period of 1750 h.
NASA Astrophysics Data System (ADS)
McEvoy, Helen C.; Simpson, Robert; Machin, Graham
2004-04-01
The use of infrared tympanic thermometers for monitoring patient health is widespread. However, studies into the performance of these thermometers have questioned their accuracy and repeatability. To give users confidence in these devices, and to provide credibility in the measurements, it is necessary for them to be tested using an accredited, standard blackbody source, with a calibration traceable to the International Temperature Scale of 1990 (ITS-90). To address this need the National Physical Laboratory (NPL), UK, has recently set up a primary ear thermometer calibration (PET-C) source for the evaluation and calibration of tympanic (ear) thermometers over the range from 15 °C to 45 °C. The overall uncertainty of the PET-C source is estimated to be +/- 0.04 °C at k = 2. The PET-C source meets the requirements of the European Standard EN 12470-5: 2003 Clinical thermometers. It consists of a high emissivity blackbody cavity immersed in a bath of stirred liquid. The temperature of the blackbody is determined using an ITS-90 calibrated platinum resistance thermometer inserted close to the rear of the cavity. The temperature stability and uniformity of the PET-C source was evaluated and its performance validated. This paper provides a description of the PET-C along with the results of the validation measurements. To further confirm the performance of the PET-C source it was compared to the standard ear thermometer calibration sources of the National Metrology Institute of Japan (NMIJ), Japan and the Physikalisch-Technische Bundesanstalt (PTB), Germany. The results of this comparison will also be briefly discussed. The PET-C source extends the capability for testing ear thermometers offered by the NPL body temperature fixed-point source, described previously. An update on the progress with the commercialisation of the fixed-point source will be given.
Infrared cameras are potential traceable "fixed points" for future thermometry studies.
Yap Kannan, R; Keresztes, K; Hussain, S; Coats, T J; Bown, M J
2015-01-01
The National physical laboratory (NPL) requires "fixed points" whose temperatures have been established by the International Temperature Scale of 1990 (ITS 90) be used for device calibration. In practice, "near" blackbody radiators together with the standard platinum resistance thermometer is accepted as a standard. The aim of this study was to report the correlation and limits of agreement (LOA) of the thermal infrared camera and non-contact infrared temporal thermometer against each other and the "near" blackbody radiator. Temperature readings from an infrared thermography camera (FLIR T650sc) and a non-contact infrared temporal thermometer (Hubdic FS-700) were compared to a near blackbody (Hyperion R blackbody model 982) at 0.5 °C increments between 20-40 °C. At each increment, blackbody cavity temperature was confirmed with the platinum resistance thermometer. Measurements were taken initially with the thermal infrared camera followed by the infrared thermometer, with each device mounted in turn on a stand at a fixed distance of 20 cm and 5 cm from the blackbody aperture, respectively. The platinum thermometer under-estimated the blackbody temperature by 0.015 °C (95% LOA: -0.08 °C to 0.05 °C), in contrast to the thermal infrared camera and infrared thermometer which over-estimated the blackbody temperature by 0.16 °C (95% LOA: 0.03 °C to 0.28 °C) and 0.75 °C (95% LOA: -0.30 °C to 1.79 °C), respectively. Infrared thermometer over-estimates thermal infrared camera measurements by 0.6 °C (95% LOA: -0.46 °C to 1.65 °C). In conclusion, the thermal infrared camera is a potential temperature reference "fixed point" that could substitute mercury thermometers. However, further repeatability and reproducibility studies will be required with different models of thermal infrared cameras.
Sostman, H E
1977-01-01
I discuss the traceability of calibration of electronic thermometers to thermometric constants of nature or to the National Bureau of Standards, form a manufacturer's basic standards through the manufacturing process to the user's laboratory. Useful electrical temperature sensors, their advantages, and means for resolving their disadvantages are described. I summarize our development of a cell for realizing the melting phase equilibrium of pure gallium (at 29.770 degrees C) as a thermometer calibration fixed point, and enumerate its advantages in the routine calibration verification of electrical thermometers in the clinical chemistry laboratory.
ERIC Educational Resources Information Center
Vitoriano, Felipe A.; Teles, Vânia L. G.; Rizzatti, Ivanise M.; Pesssoa de Lima, Régia C.
2016-01-01
This work discusses the construction and evaluation of a digital thermometer especially designed to be operated by people with visual disabilities. The accessibility thermometer can be used as an educational tool in practical activities in classes for sighted and visually impaired students, with the aim of helping those with special needs gain…
Time's Up, Turkey--Pop-Up Thermometers
ERIC Educational Resources Information Center
Moyer, Richard; Everett, Susan
2009-01-01
Meat thermometers can be awkward to use in terms of placement and avoidance of bones. Because of these problems, each year 30 million Thanksgiving turkeys have a built-in thermometer that pops up when the turkey is properly cooked. Turkey timers are an example of how engineering solved a common, everyday problem. The following 5E learning cycle…
Tympanic thermometer performance validation by use of a body-temperature fixed point blackbody
NASA Astrophysics Data System (ADS)
Machin, Graham; Simpson, Robert
2003-04-01
The use of infrared tympanic thermometers within the medical community (and more generically in the public domain) has recently grown rapidly, displacing more traditional forms of thermometry such as mercury-in-glass. Besides the obvious health concerns over mercury the increase in the use of tympanic thermometers is related to a number of factors such as their speed and relatively non-invasive method of operation. The calibration and testing of such devices is covered by a number of international standards (ASTM1, prEN2, JIS3) which specify the design of calibration blackbodies. However these calibration sources are impractical for day-to-day in-situ validation purposes. In addition several studies (e.g. Modell et al4, Craig et al5) have thrown doubt on the accuracy of tympanic thermometers in clinical use. With this in mind the NPL is developing a practical, portable and robust primary reference fixed point source for tympanic thermometer validation. The aim of this simple device is to give the clinician a rapid way of validating the performance of their tympanic thermometer, enabling the detection of mal-functioning thermometers and giving confidence in the measurement to the clinician (and patient!) at point of use. The reference fixed point operates at a temperature of 36.3 °C (97.3 °F) with a repeatability of approximately +/- 20 mK. The fixed-point design has taken into consideration the optical characteristics of tympanic thermometers enabling wide-angled field of view devices to be successfully tested. The overall uncertainty of the device is estimated to be is less than 0.1°C. The paper gives a description of the fixed point, its design and construction as well as the results to date of validation tests.
González, A Michelle; Mann, F A; Preziosi, Diane E; Meadows, Richard L; Wagner-Mann, Colette C
2002-08-01
To compare measurements of body temperature obtained with auricular thermometers versus rectal thermometers in dogs with otitis externa. Prospective study. 100 client-owned dogs: 50 with and 50 without clinical evidence of otitis externa. Dogs were evaluated for the presence of otitis externa on the basis of clinical signs, otoscopic examination, and cytologic evaluation of ear exudate. Auricular and rectal temperatures were obtained simultaneously in all dogs prior to and following ear examination. There was a high correlation between auricular and rectal temperatures in dogs with otitis externa both prior to and after ear manipulation. Significant differences were not detected in temperature measurements among dogs with different degrees of otitis externa. Auricular temperature readings obtained by use of an auricular thermometer in dogs with otitis externa are accurate measurements of body temperature, compared with rectal temperature measurements. Temperature measurements are reliable before and after examination of the ear canal.
Nie, Jing; Zhang, Bo; Duan, Yan-Chao; Hu, Yue-Hua; Gao, Xin-Ying; Gong, Jian; Cheng, Ming; Li, Yan-Qing
2014-03-07
Intraperitoneal foreign bodies such as retained surgical instruments can cause intestinal obstruction. However, intestinal obstruction due to transmural migration of foreign bodies has rarely been reported. Here, we report a case of intestinal obstruction due to a clinical thermometer which migrated from the bladder into the abdominal cavity. A 45-year-old man was admitted to our hospital with a one-year history of recurrent lower abdominal cramps. Two days before admission, the abdominal cramps aggravated. Intestinal obstruction was confirmed with upright abdominal radiography and computerized tomography scan which showed dilation of the small intestines and a thermometer in the abdominal cavity. Then laparotomy was performed. A scar was observed at the fundus of the bladder and a thermometer was adhering to the small bowels and mesentery which resulted in intestinal obstruction. Abdominal cramps were eliminated and defecation and flatus recovered soon after removal of the thermometer.
A silicon nanowire heater and thermometer
NASA Astrophysics Data System (ADS)
Zhao, Xingyan; Dan, Yaping
2017-07-01
In the thermal conductivity measurements of thermoelectric materials, heaters and thermometers made of the same semiconducting materials under test, forming a homogeneous system, will significantly simplify fabrication and integration. In this work, we demonstrate a high-performance heater and thermometer made of single silicon nanowires (SiNWs). The SiNWs are patterned out of a silicon-on-insulator wafer by CMOS-compatible fabrication processes. The electronic properties of the nanowires are characterized by four-probe and low temperature Hall effect measurements. The I-V curves of the nanowires are linear at small voltage bias. The temperature dependence of the nanowire resistance allows the nanowire to be used as a highly sensitive thermometer. At high voltage bias, the I-V curves of the nanowire become nonlinear due to the effect of Joule heating. The temperature of the nanowire heater can be accurately monitored by the nanowire itself as a thermometer.
Evaluation of industrial platinum resistance thermometers
NASA Technical Reports Server (NTRS)
Daryabeigi, Kamran; Dillontownes, Lawrence A.; Alderfer, David W.
1987-01-01
The calibration and stability of four surface temperature measuring industrial platinum resistance thermometers for use in the temperature range -120 C to 160 C was investigated. It was found that the calibration formulation of the International Practical Temperature Scale of 1968 provided the most accurate calibration. It was also found that all the resistance thermometers suffered from varying degrees of instability and hysteresis.
Intravenous fluid temperature management by infrared thermometer.
Lapostolle, Frédéric; Catineau, Jean; Le Toumelin, Philippe; Proust, Clément; Garrigue, Bruno; Galinski, Michel; Adnet, Frédéric
2006-03-01
The management of intravenous (IV) fluid temperature is a daily challenge in critical care, anesthesiology, and emergency medicine. Infusion of IV fluids at the right temperature partly influences clinical outcomes of critically ill patients. Nowadays, intravenous fluid temperature is poorly managed, as no suitable device is routinely available. Infrared (IR) thermometers have been recently developed for industrial, personal, or medical purposes. The aim of this study was to evaluate the accuracy of an IR thermometer in measuring temperature of warmed and cooled infusion fluids in fluid bags. This study compared temperatures simultaneously recorded by an infrared thermometer and a temperature sensor. Temperatures of warmed (41 degrees C) and cooled (4 degrees C) infusion fluids in fluid bags were recorded by 2 independent operators every minute until IV bags' temperature reached ambient temperature. The relation curve was established with 576 measures. Temperature measures performed with an IR thermometer were perfectly linear and perfectly correlated with the reference method (R(2) = 0.995, P < 10(-5)). Infrared thermometers are efficient to measure IV fluid bag temperature in the range of temperatures used in clinical practice. As these devices are easy to use and inexpensive, they could be largely used in critical care, anesthesiology, or emergency medicine.
Preliminary Results of a New Type of Non-Hazardous Liquid-Filled Precision Glass Thermometer
NASA Astrophysics Data System (ADS)
Miller, Charles J.; Emory, Deanne Miller
2003-09-01
Miller & Weber, Inc. has developed several liquids that, when used properly, will perform as mercury in a liquid-in-glass thermometer. These liquids are non-hazardous per OSHA standards, non-toxic per EPA standards and biodegradable. This paper discusses the research, development and testing accomplished before bringing the finished thermometers, marketed under the brand name PerformaTherm®, to market.
Hand-touch method for detection of neonatal hypothermia in Nepal.
Tuitui, Roshani Laxmi; Suwal, Satya Narayan; Shrestha, Sarala
2011-06-01
Neonatal hypothermia is the fourth leading causes of neonatal death in Nepal. Thus, it is the caregivers' responsibility to identify the hypothermia by using valid and less time consuming method like hand-touch method. Therefore, we examined the diagnostic validity of hand-touch method against low-reading mercury (LRM) thermometer for detecting neonatal hypothermia. We assessed neonate's temperature first by hand-touch method, then by LRM thermometer and tympanic thermometer among 100 full-term neonates, delivered within 24 h in Maternity Ward of Tribhuvan University Teaching Hospital, Nepal. We used World Health Organization (1997) criteria for classification of neonatal hypothermia. The sensitivity and specificity of the hand-touch method for detection of neonatal hypothermia were 95.6% and 70.1% against LRM thermometer and 76.6% and 83% against the tympanic thermometer, respectively. Touching method is practical and therefore has a good diagnostic validity; it can be introduced in essential newborn care package after giving adequate training to caregivers.
Barnwal, Ravi Pratap; Loh, Edmund; Godin, Katherine S.; Yip, Jordan; Lavender, Hayley; Tang, Christoph M.; Varani, Gabriele
2016-01-01
Neisseria meningitidis causes bacterial meningitis and septicemia. It evades the host complement system by upregulating expression of immune evasion factors in response to changes in temperature. RNA thermometers within mRNAs control expression of bacterial immune evasion factors, including CssA, in the 5′-untranslated region of the operon for capsule biosynthesis. We dissect the molecular mechanisms of thermoregulation and report the structure of the CssA thermometer. We show that the RNA thermometer acts as a rheostat, whose stability is optimized to respond in a small temperature range around 37°C as occur within the upper airways during infection. Small increases in temperature gradually open up the structure to allow progressively increased access to the ribosome binding site. Even small changes in stability induced by mutations of imperfect base pairs, as in naturally occurring polymorphisms, shift the thermometer response outside of the desired temperature range, suggesting that its activity could be modulated by pharmacological intervention. PMID:27369378
Moen, Stephan Craig; Meyers, Craig Glenn; Petzen, John Alexander; Foard, Adam Muhling
2012-08-07
A method of calibrating a nuclear instrument using a gamma thermometer may include: measuring, in the instrument, local neutron flux; generating, from the instrument, a first signal proportional to the neutron flux; measuring, in the gamma thermometer, local gamma flux; generating, from the gamma thermometer, a second signal proportional to the gamma flux; compensating the second signal; and calibrating a gain of the instrument based on the compensated second signal. Compensating the second signal may include: calculating selected yield fractions for specific groups of delayed gamma sources; calculating time constants for the specific groups; calculating a third signal that corresponds to delayed local gamma flux based on the selected yield fractions and time constants; and calculating the compensated second signal by subtracting the third signal from the second signal. The specific groups may have decay time constants greater than 5.times.10.sup.-1 seconds and less than 5.times.10.sup.5 seconds.
Huang, Ming; Tamura, Toshiyo; Chen, Wenxi; Kanaya, Shigehiko
2015-01-01
To help pave a path toward the practical use of continuous unconstrained noninvasive deep body temperature measurement, this study aims to evaluate the structural and thermophysical effects on measurement accuracy for the dual-heat-flux method (DHFM). By considering the thermometer's height, radius, conductivity, density and specific heat as variables affecting the accuracy of DHFM measurement, we investigated the relationship between those variables and accuracy using 3-D models based on finite element method. The results of our simulation study show that accuracy is proportional to the radius but inversely proportional to the thickness of the thermometer when the radius is less than 30.0mm, and is also inversely proportional to the heat conductivity of the heat insulator inside the thermometer. The insights from this study would help to build a guideline for design, fabrication and optimization of DHFM-based thermometers, as well as their practical use. Copyright © 2014 Elsevier Ltd. All rights reserved.
Germanium Resistance Thermometer For Subkelvin Temperatures
NASA Technical Reports Server (NTRS)
Castles, Stephen H.
1993-01-01
Improved germanium resistance thermometer measures temperatures as small as 0.01 K accurately. Design provides large area for electrical connections (to reduce electrical gradients and increase sensitivity to changes in temperatures) and large heat sink (to minimize resistance heating). Gold pads on top and bottom of germanium crystal distribute electrical current and flow of heat nearly uniformly across crystal. Less expensive than magnetic thermometers or superconducting quantum interference devices (SQUID's) otherwise used.
[Application of self-developed moxibustion thermometer in experiment teaching].
Zhang, Jing; Sun, Yan; Zhang, Yongchen; Lu, Yan
2017-04-12
In order to improve the teaching quality of moxibustion experiment, a moxibustion thermometer was self-developed to monitor the real-time and continuous data of moxibustion temperature at different time points during the experiment. After teacher's explanation and demonstration of experiment process, the students used the moxibustion thermometer to monitor the change of temperature data and extended the experiment design. In the process of experiment class, the students found the temperature of the object tested increased rapidly, arrived at the highest temperature and slowly reduced. In addition, with learned knowledge, the students were able to design the feasible experiment scheme. The self-developed moxibustion thermometer operates smoothly in actual teaching, with stable experiment data and less experiment error, which obtained satisfactory teaching effect.
Detection and management of hypothermia at a large outdoor endurance event in the United kingdom.
Bhangu, Aneel; Parmar, Rinesh
2010-06-01
Optimum detection of hypothermia in athletes during outdoor exposure events remains controversial. The aims of this study were firstly to assess whether temperature readings affected competitor discharge from the treatment station and secondly to assess agreement between oral and tympanic thermometer measurements. All competitors treated for symptomatic hypothermia at an outdoor endurance event in the United Kingdom during January 2009 were included. Temperature readings were taken using oral (Digitemp digital oral thermometer) and tympanic (Braun Thermoscan IRT 4520 ExacTemp) thermometers, with a temperature <35 degrees C classifying hypothermia. From 4700 competitors, 64 (1.4%) were treated for symptomatic hypothermia. Of these, 92% were male, the mean age was 26 years, and the mean treatment time was 25 minutes. There was no severe/life-threatening hypothermia, and no competitors required transport to a hospital for hypothermia. At discharge, 19% of competitors were still classed as hypothermic in the oral group and 28% in the tympanic group, despite competitors only being discharged when no longer symptomatic. Oral readings at discharge were significantly lower than tympanic readings (33.8 degrees C [95% CI, 33.2 degrees C to 34.5 degrees C] vs 35.0 degrees C [95% CI, 34.6 degrees C to 35.3 degrees C], respectively, P = .003). The use of thermometers had a limited role in discharging competitors at this event, who were apparently safely discharged when no longer symptomatic. Treating clinicians and the thermometers did not always agree on whether a patient was hypothermic or not. Oral and tympanic thermometers had poor agreement. Routine thermometer readings at future events may be unnecessary, although screening competitors of concern will remain useful. Copyright (c) 2010 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.
Noise thermometry at ultra-low temperatures.
Rothfuss, D; Reiser, A; Fleischmann, A; Enss, C
2016-03-28
The options for primary thermometry at ultra-low temperatures are rather limited. In practice, most laboratories are using (195)Pt NMR thermometers in the microkelvin range. In recent years, current sensing direct current superconducting quantum interference devices (DC-SQUIDs) have enabled the use of noise thermometry in this temperature range. Such devices have also demonstrated the potential for primary thermometry. One major advantage of noise thermometry is the fact that no driving current is needed to operate the device and thus the heat dissipation within the thermometer can be reduced to a minimum. Ultimately, the intrinsic power dissipation is given by the negligible back action of the readout SQUID. For thermometry in low-temperature experiments, current noise thermometers and magnetic flux fluctuation thermometers have proved to be most suitable. To make use of such thermometers at ultra-low temperatures, we have developed a cross-correlation technique that reduces the amplifier noise contribution to a negligible value. For this, the magnetic flux fluctuations caused by the Brownian motion of the electrons in our noise source are measured inductively by two DC-SQUID magnetometers simultaneously and the signals from these two channels are cross-correlated. Experimentally, we have characterized a thermometer made of a cold-worked high-purity copper cylinder with a diameter of 5 mm and a length of 20 mm for temperatures between 42 μK and 0.8 K. For a given temperature, a measuring time below 1 min is sufficient to reach a precision of better than 1%. The extremely low power dissipation in the thermometer allows continuous operation without heating effects. © 2016 The Author(s).
Towards a practical Johnson noise thermometer for long-term measurements in harsh environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greenen, Adam; Pearce, Jonathan; Cruickshank, David
The impact of mechanical and chemical changes in conventional sensors such as thermocouples and resistance thermometers can be avoided by instead using temperature sensors based on fundamental thermometry. A prime example of this is Johnson noise thermometry, which is based on measurement of the fluctuations in the voltage of a resistor arising from thermal motion of charge carriers - i.e. the 'Johnson noise'. A Johnson noise thermometer never needs calibration and is insensitive to the condition of the sensor material. It is therefore ideally suited to long-term temperature measurements in harsh environments, such as nuclear reactor coolant circuits, in-pile measurements,more » nuclear waste management and storage, and severe accident monitoring. There have been a number of previous attempts to develop a Johnson noise thermometer for the nuclear industry, but none have reached commercial exploitation because of technical problems in practical implementation. The main challenge is to extract the tiny Johnson noise signal from ambient electrical noise influences, both from the internal amplification electronics, and from external electrical noise sources. Recent advances in electronics technology and digital signal processing techniques have opened up new possibilities for developing a viable, practical Johnson noise thermometer. We describe a project funded by the UK Technology Strategy Board (now Innovate UK) 'Developing the nuclear supply chain' call, currently underway, to develop a practical Johnson noise thermometer that makes use of innovative electronics for ultralow noise amplification and signal processing. The new electronics technology has the potential to help overcome the problems encountered with previous attempts at constructing a practical Johnson noise thermometer. An outline of the new developments is presented, together with an overview of the current status of the project. (authors)« less
The use of infrared ear thermometers in pediatric and family practice offices.
Silverman, B G; Daley, W R; Rubin, J D
1998-01-01
To describe the use of infrared (IR) ear thermometers in pediatric and family practice offices. The authors mailed a questionnaire to 350 randomly selected members of the American Academy of Pediatrics and to 355 randomly selected members of the American Academy of Family Physicians. Of respondents in clinical practice, 78% had used IR ear thermometers at least once in the past; 65% of pediatricians and 64% of family practice physicians were current users. Seventeen percent of pediatric offices and 18% of family practice offices that had used IR ear thermometers had discontinued use, most citing inaccuracy or lack of staff trust in the device. Pediatric offices were less likely than family practice offices to use the device in well neonates and sick neonates and more likely to use it in sick children. Advantages cited included rapid readings, ease of use, and accuracy. Seventy-five percent of current users reported at least one problem, including low readings and lack of staff trust. IR ear thermometers are widely used in pediatric and family practice offices. Some offices limit use of these devices to older children and adults, and most of the offices surveyed report using other devices as a check on the accuracy of IR thermometers. Statements by professional organizations that provide user guidelines and establish appropriate age cut-offs would be helpful.
Dentists' self assessment of burnout: an internet feedback tool.
te Brake, Hans; Eijkman, Michiel; Hoogstraten, Johan; Gorter, Ronald
2005-06-01
The Stress Thermometer is an easily accessible Internet-based instrument for feedback on work stress and burnout. The aim of this paper is to describe the development of this instrument and to determine its applicability within the dental practice. The Stress Thermometer was made accessible to all members of the Dutch Dental Association, of which 77% of all Dutch dentists are members. Frequency of use was determined, and descriptive data was collected. During an evaluation period of 5 months at least 12% of all possible respondents made use of the Stress Thermometer. Descriptive characteristics of the response group, as well as levels of burnout and work stress, corresponded with those found in the Dutch dentist population. However, some deviations were also present. Results indicate the applicability of the Stress Thermometer to a representative variety of dentists. Although the deviations found should not be ignored in future use, the Stress Thermometer was successful in reaching a population that is difficult to reach. It effectively calls attention to sensitive personal issues concerning work-related stress and burnout.
Measurement time and statistics for a noise thermometer with a synthetic-noise reference
NASA Astrophysics Data System (ADS)
White, D. R.; Benz, S. P.; Labenski, J. R.; Nam, S. W.; Qu, J. F.; Rogalla, H.; Tew, W. L.
2008-08-01
This paper describes methods for reducing the statistical uncertainty in measurements made by noise thermometers using digital cross-correlators and, in particular, for thermometers using pseudo-random noise for the reference signal. First, a discrete-frequency expression for the correlation bandwidth for conventional noise thermometers is derived. It is shown how an alternative frequency-domain computation can be used to eliminate the spectral response of the correlator and increase the correlation bandwidth. The corresponding expressions for the uncertainty in the measurement of pseudo-random noise in the presence of uncorrelated thermal noise are then derived. The measurement uncertainty in this case is less than that for true thermal-noise measurements. For pseudo-random sources generating a frequency comb, an additional small reduction in uncertainty is possible, but at the cost of increasing the thermometer's sensitivity to non-linearity errors. A procedure is described for allocating integration times to further reduce the total uncertainty in temperature measurements. Finally, an important systematic error arising from the calculation of ratios of statistical variables is described.
Eliminating Mercury Thermometers from the Lab.
ERIC Educational Resources Information Center
Everett, T. Stephen
1997-01-01
Compares the precision, accuracy, and response of a cooking probe to a standard mercury thermometer in side-by-side heating in temperature baths, simple and fractional distillations, and melting point determination. (DDR)
THE DYNAMIC RESPONSE OF THERMOMETER-WELL ASSEMBLIES.
parameter models of the thermometric system were constructed and gave acceptable agreement with the experimental results. These models can be used to predict the dynamic behavior of any similar thermometer system. (Author)
Thermal Conductivity and Liquid Crystal Thermometers.
ERIC Educational Resources Information Center
Edge, R. D., Ed.
1993-01-01
Describes using stock liquid crystal postcards as inexpensive classroom thermometers. Also suggests using these postcards as a good visual temperature indicator for classroom demonstrations such as temperature gradients. One such activity is provided. (MVL)
NASA Astrophysics Data System (ADS)
Pavese, F.; Szmyrka-Grzebyk, A.; Lipinski, L.; Manuszkiewicz, H.; Qiu, Ping; Zhang, Jin Tao; Lin, Peng; Li, Xing Wei
2008-02-01
Given the practical impossibility of obtaining new precision Rh-0.5at%Fe resistance thermometers in recent years, the possible re-starting of the production of such thermometers in Yunnan (China) was explored by Istituto Nazionale di Ricerca Metrologica (INRIM). Ten prototypes of the new production were made available in early 2006. The paper reports the preliminary data from the testing performed to date on these prototypes at National Institute of Metrology (NIM) and Instytut Niskich Temperatur i Badan Strukturalnych (INTiBS). Although a problem with the alloy composition was detected, the reproducibility results on thermal cycling are very encouraging. Resistance-temperature ( R- T) characteristics below 30 K, though not identical with those of similar thermometers formerly available from Tinsley and VNIIFTRI, are still suitable for accurate metrology.
Experimental study of temperature sensor for an ocean-going liquid hydrogen (LH2) carrier
NASA Astrophysics Data System (ADS)
Nakano, A.; Shimazaki, T.; Sekiya, M.; Shiozawa, H.; Aoyagi, A.; Ohtsuka, K.; Iwakiri, T.; Mikami, Z.; Sato, M.; Kinoshita, K.; Matsuoka, T.; Takayama, Y.; Yamamoto, K.
2018-04-01
The prototype temperature sensors for an ocean-going liquid hydrogen (LH2) carrier were manufactured by way of trial. All of the sensors adopted Platinum 1000 (PT-1000) resistance thermometer elements. Various configurations of preproduction temperature sensors were tested in AIST's LH2 test facility. In the experiments, a PT-1000 resistance thermometer, calibrated at the National Metrology Institute of Japan at AIST, was used as the standard thermometer. The temperatures measured by the preproduction sensors were compared with the temperatures measured by the standard thermometer, and the measurement accuracy of the temperature sensors in LH2 was investigated and discussed. It was confirmed that the measurement accuracies of the preproduction temperature sensors were within ±50 mK, which is the required measurement accuracy for a technical demonstration ocean-going LH2 carrier.
Operational methods of thermodynamics. Volume 1 - Temperature measurement
NASA Astrophysics Data System (ADS)
Eder, F. X.
The principles of thermometry are examined, taking into account the concept of temperature, the Kelvin scale, the statistical theory of heat, negative absolute temperatures, the thermodynamic temperature scale, the thermodynamic temperature scale below 1 K, noise thermometry, temperature scales based on black-body radiation, acoustical thermometry, and the International Practical Temperature Scale 1968. Aspects of practical temperature measurement are discussed, giving attention to thermometers based on the expansion of a gas or a liquid, instruments utilizing the relative thermal expansion of two different metals, devices measuring the vapor pressure of a liquid, thermocouples, resistance thermometers, radiation pyrometers of various types, instruments utilizing the temperature dependence of a number of material characteristics, devices for temperature control, thermometer calibration, and aspects of thermometer installation and inertia. A description is presented of the approaches employed for the measurement of low temperatures.
Device Would Monitor Body Parameters Continuously
NASA Technical Reports Server (NTRS)
Cook, Joseph S., Jr.
1995-01-01
Proposed miniature electronic circuit continuously measures temperature of human subject. Once mounted on subject's skin with medical adhesive tape, electronic thermometer remains in thermal equilibrium with subject's body; thereafter, no need to wait until thermometer reaches body temperature before taking reading. Design provides for switches used to set alarm alerting medical attendants if subject's temperature exceeds critical level. For use on very young child, electronic thermometer sewed into shirt or other suitable garment; device held in contact with skin, and child could not swallow it. Replacement of sensor and computing algorithm changes temperature monitor to cardiorespiratory monitor.
Time-lapse and slow-motion tracking of temperature changes: response time of a thermometer
NASA Astrophysics Data System (ADS)
Moggio, L.; Onorato, P.; Gratton, L. M.; Oss, S.
2017-03-01
We propose the use of a smartphone based time-lapse and slow-motion video techniques together with tracking analysis as valuable tools for investigating thermal processes such as the response time of a thermometer. The two simple experimental activities presented here, suitable also for high school and undergraduate students, allow one to measure in a simple yet rigorous way the response time of an alcohol thermometer and show its critical dependence on the properties of the surrounding environment giving insight into instrument characteristics, heat transfer and thermal equilibrium concepts.
Evaluation of the Use of Optical Fiber Thermometers for Thermal Control of the Quench Module Insert
NASA Technical Reports Server (NTRS)
Jones, Matthew R.; Farmer, Jeffrey T.; Breeding, Shawn P.
2001-01-01
Issues regarding the use of optical fiber thermometers to control heater settings in a microgravity vacuum furnace are addressed. It is desirable to use these probes in environments such as the International Space Station, because they can be operated without re-calibration for extended periods. However, the analysis presented in this paper shows that temperature readings obtained using optical fiber thermometers can be corrupted by emissions from the fiber when extended portions of the probe are exposed to elevated temperatures.
Evaluation of the Use of Optical Fiber Thermometers for Thermal Control of the Quench Module Insert
NASA Technical Reports Server (NTRS)
Jones, Matthew R.; Farmer, Jeffrey T.; Breeding, Shawn P.
1999-01-01
Issues regarding the use of optical fiber thermometers to control heater settings in a microgravity vacuum furnace are addressed. It is desirable to use these probes in environments such as the International Space Station, because they can be operated without re-calibration for extended periods. However, the analysis presented in this paper shows that temperature readings obtained using optical fiber thermometers are corrupted due to emissions from the fiber when extended portions of the probe are exposed to elevated temperatures.
Reliability of body temperature measurements in hospitalised older patients.
Giantin, Valter; Toffanello, Elena D; Enzi, Giuliano; Perissinotto, Egle; Vangelista, Stefania; Simonato, Matteo; Ceccato, Corrado; Manzato, Enzo; Sergi, Giuseppe
2008-06-01
To compare different body temperature assessment methods in older people and to assess the role of cognitive and functional characteristics in temperature recordings. Axillary gallium-in-glass thermometers are commonly used. Their accuracy depends on the proper placement of the device and their permanence in place for eight minutes. With adequate instruction, well-functioning patients can measure their axillary temperature by themselves, while in cognitively and functionally impaired older people, inadequate understanding of instructions and misplacement of the thermometer might determine significant recording errors. Electronic ear and axillary temperature measurements are faster, but their accuracy has not been demonstrated convincingly with older people. Patients (n = 107; aged 65-104 years) were recruited. Barthel Index and Short Portable Mental Status Questionnaire (SPMSQ) scores were obtained for each patient. Temperature readings were obtained using: the axillary gallium-in-glass thermometer, with (T(nurse)) and without (T(self)) the nurse's assistance; the electronic axillary thermometer (T(el)) and the infrared tympanic thermometer (T(tymp)). The T(nurse) was considered as the reference method. Mean difference and standard deviation (mean +/- SD) in temperature recordings between the different techniques and T(nurse) differed significantly from zero for T(self) (-0.40 SD 0.42) and T(tymp) (+0.19 SD 0.48). No significant differences in temperature recordings emerged between T(nurse) and T(el). In simple linear regression models, the difference between T(self) and T(nurse) significantly correlated with age, gender, SPMSQ score and Barthel Index. Multiple linear regression analysis showed an underestimation of body temperature in older patients with cognitive impairments. Unassisted gallium-in-glass axillary temperature assessment is inadequate, in older patients. The differences between T(self) and T(nurse) are significantly influenced by age and mental decline. T(el) provides adequate accuracy. Relevance to clinical practice. In geriatric settings, the electronic axillary thermometer is a safe and accurate alternative to the more traditional gallium-in-glass thermometer, with the advantage of saving time (five seconds in recording vs. eight minutes).
Development of an Inductively Coupled Thermometer for a Cryogenic Half-Wave Plate
NASA Astrophysics Data System (ADS)
Madurowicz, Alexander; Kusaka, Akito
2017-01-01
The current state of Cosmic Microwave Background (CMB) research has focused much attention on the measurement of polarization. In an effort to modulate the CMB polarization while also minimizing photon noise due to thermal emission, we are developing a sapphire half-wave plate (HWP) cooled to 50 K rotating at 2 Hz on a superconducting magnetic levitating bearing. In order to measure the temperature of the rotor without making physical contact, we designed an inductively coupled cryogenic thermometer. The complex impedance of the circuit has a resonant peak when driven around 1 MHz. The width of this resonance is dependent on the value of the resistor, which varies with temperature and functions as a thermometer once calibrated. In this talk, we will present results from stationary measurements of this impedance and discuss the temperature accuracy of this thermometer, as well as a preliminary circuit design to measure this impedance during the HWP rotation.
High speed infrared radiation thermometer, system, and method
Markham, James R.
2002-01-01
The high-speed radiation thermometer has an infrared measurement wavelength band that is matched to the infrared wavelength band of near-blackbody emittance of ceramic components and ceramic thermal barrier coatings used in turbine engines. It is comprised of a long wavelength infrared detector, a signal amplifier, an analog-to-digital converter, an optical system to collect radiation from the target, an optical filter, and an integral reference signal to maintain a calibrated response. A megahertz range electronic data acquisition system is connected to the radiation detector to operate on raw data obtained. Because the thermometer operates optimally at 8 to 12 .mu.m, where emittance is near-blackbody for ceramics, interferences to measurements performed in turbine engines are minimized. The method and apparatus are optimized to enable mapping of surface temperatures on fast moving ceramic elements, and the thermometer can provide microsecond response, with inherent self-diagnostic and calibration-correction features.
DNA nanostructure-based fluorescence thermometer with silver nanoclusters
NASA Astrophysics Data System (ADS)
Bu, Congcong; Mu, Lixuan; Cao, Xingxing; Chen, Min; She, Guangwei; Shi, Wensheng
2018-07-01
DNA nanostructure-based fluorescence thermometers were fabricated by linking fluorescent silver nanoclusters (AgNCs) and guanine-rich(G-rich)DNA chains via a thermally sensitive DNA stem-loop at terminals 5‧ and 3‧. Variations of temperature alter the distance between the AgNCs and G-rich DNA chain, affecting the interaction between them. As a result, the intensity of fluorescence emission from the AgNCs at 636 nm can be sensitively modulated. It was found that the intensity of such red emission is more temperature sensitive than the equivalent green emission at 543 nm; sensitivity of ‑3.6%/°C was achieved. Through variation of the melting temperature of the DNA stem-loop, the response temperature range of the thermometers could be readily adjusted. Novel DNA nanostructure-based fluorescence thermometers as described in this work are anticipated to be able to measure the temperature of biological systems at small scales—even a single cell.
Nanoscale temperature mapping in operating microelectronic devices
Mecklenburg, Matthew; Hubbard, William A.; White, E. R.; ...
2015-02-05
We report that modern microelectronic devices have nanoscale features that dissipate power nonuniformly, but fundamental physical limits frustrate efforts to detect the resulting temperature gradients. Contact thermometers disturb the temperature of a small system, while radiation thermometers struggle to beat the diffraction limit. Exploiting the same physics as Fahrenheit’s glass-bulb thermometer, we mapped the thermal expansion of Joule-heated, 80-nanometer-thick aluminum wires by precisely measuring changes in density. With a scanning transmission electron microscope (STEM) and electron energy loss spectroscopy (EELS), we quantified the local density via the energy of aluminum’s bulk plasmon. Rescaling density to temperature yields maps with amore » statistical precision of 3 kelvin/hertz ₋1/2, an accuracy of 10%, and nanometer-scale resolution. Lastly, many common metals and semiconductors have sufficiently sharp plasmon resonances to serve as their own thermometers.« less
DNA nanostructure-based fluorescence thermometer with silver nanoclusters.
Bu, Congcong; Mu, Lixuan; Cao, XIngxing; Chen, Min; She, Guangwei; Shi, Wensheng
2018-04-27
Linking the fluorescent silver nanoclusters (AgNCs) and guanine-rich(G-rich)DNA chains by the thermal sensitive DNA stem-loop at teminal 5' and 3', DNA nanostructure-based fluorescence thermometers were fabricated. The variations of the temperature alter the distance between AgNCs and G-rich DNA chain, which could affect the interaction between them. As a result, the intensity of fluorescence emission from AgNCs at 636 nm can be sensitively modulated. It was found that such red emission is more sensitive to the temperature comparing with its intrinsic green emission at 543 nm, and sensitivity of -3.6%/℃ was achieved. Varying the melting temperature of the DNA stem-loop could readily adjust the response temperature range of thermometers. Novel DNA nanostructure-based fluorescence thermometers in this work could be anticipated to measure the temperature of biological system, even a single cell. © 2018 IOP Publishing Ltd.
Validation of Calculations in a Digital Thermometer Firmware
NASA Astrophysics Data System (ADS)
Batagelj, V.; Miklavec, A.; Bojkovski, J.
2014-04-01
State-of-the-art digital thermometers are arguably remarkable measurement instruments, measuring outputs from resistance thermometers and/or thermocouples. Not only that they can readily achieve measuring accuracies in the parts-per-million range, but they also incorporate sophisticated algorithms for the transformation calculation of the measured resistance or voltage to temperature. These algorithms often include high-order polynomials, exponentials and logarithms, and must be performed using both standard coefficients and particular calibration coefficients. The numerical accuracy of these calculations and the associated uncertainty component must be much better than the accuracy of the raw measurement in order to be negligible in the total measurement uncertainty. In order for the end-user to gain confidence in these calculations as well as to conform to formal requirements of ISO/IEC 17025 and other standards, a way of validation of these numerical procedures performed in the firmware of the instrument is required. A software architecture which allows a simple validation of internal measuring instrument calculations is suggested. The digital thermometer should be able to expose all its internal calculation functions to the communication interface, so the end-user can compare the results of the internal measuring instrument calculation with reference results. The method can be regarded as a variation of the black-box software validation. Validation results on a thermometer prototype with implemented validation ability show that the calculation error of basic arithmetic operations is within the expected rounding error. For conversion functions, the calculation error is at least ten times smaller than the thermometer effective resolution for the particular probe type.
ERIC Educational Resources Information Center
Aronson, Susan S.
1990-01-01
Infant and Child First Aid Training is recommended over CPR for child caregivers. Digital thermometers are considered more reliable, safer, and more versatile than other thermometers. Super-absorbent, disposable diapers are recommended as superior to cloth diapers for sanitary and health reasons. (SH)
ERIC Educational Resources Information Center
Schaefers, John
2006-01-01
An infrared (IR) thermometer lab offers the opportunity to give science students a chance to measure surface temperatures, utilizing off-the-shelf technology. Potential areas of study include astronomy (exoplanets), electromagnetic spectrum, chemistry, evaporation rates, anatomy, crystal formation, and water or liquids. This article presents one…
Summary: Disabled Submarine Heat Stress Conference
2009-09-11
by dry bulb thermometer and humidity using either a sling psychrometer or a portable battery-powered electronic device providing a direct readout of...and sling psychrometer in each compartment 3) One battery-powered electronic thermometer/hygrometer in each compartment Heat Stress When-To
Resistance thermometer has linear resistance-temperature coefficient at low temperatures
NASA Technical Reports Server (NTRS)
Kuzyk, W.
1966-01-01
Resistance thermometer incorporating a germanium resistance element with a platinum resistance element in a wheatstone bridge circuit has a linear temperature-resistance coefficient over a range from approximately minus 140 deg C to approximately minus 253 deg C.
Calibration and tests of commercial wireless infrared thermometers
USDA-ARS?s Scientific Manuscript database
Applications of infrared thermometers (IRTs) in large agricultural fields require wireless data transmission, and IRT target temperature should have minimal sensitivity to internal detector temperature. To meet these objectives, a prototype wireless IRT system was developed at USDA Agricultural Rese...
ASRDI oxygen technology survey. Volume 4: Low temperature measurement
NASA Technical Reports Server (NTRS)
Sparks, L. L.
1974-01-01
Information is presented on temperature measurement between the triple point and critical point of liquid oxygen. The criterion selected is that all transducers which may reasonably be employed in the liquid oxygen (LO2) temperature range are considered. The temperature range for each transducer is the appropriate full range for the particular thermometer. The discussion of each thermometer or type of thermometer includes the following information: (1) useful temperature range, (2) general and particular methods of construction and the advantages of each type, (3) specifications (accuracy, reproducibility, response time, etc.), (4) associated instrumentation, (5) calibrations and procedures, and (6) analytical representations.
Whispering Gallery Mode Thermometry
Corbellini, Simone; Ramella, Chiara; Yu, Lili; Pirola, Marco; Fernicola, Vito
2016-01-01
This paper presents a state-of-the-art whispering gallery mode (WGM) thermometer system, which could replace platinum resistance thermometers currently used in many industrial applications, thus overcoming some of their well-known limitations and their potential for providing lower measurement uncertainty. The temperature-sensing element is a sapphire-crystal-based whispering gallery mode resonator with the main resonant modes between 10 GHz and 20 GHz. In particular, it was found that the WGM around 13.6 GHz maximizes measurement performance, affording sub-millikelvin resolution and temperature stability of better than 1 mK at 0 °C. The thermometer system was made portable and low-cost by developing an ad hoc interrogation system (hardware and software) able to achieve an accuracy in the order of a few parts in 109 in the determination of resonance frequencies. Herein we report the experimental assessment of the measurement stability, repeatability and resolution, and the calibration of the thermometer in the temperature range from −74 °C to 85 °C. The combined standard uncertainty for a single temperature calibration point is found to be within 5 mK (i.e., comparable with state-of-the-art for industrial thermometry), and is mainly due to the employed calibration setup. The uncertainty contribution of the WGM thermometer alone is within a millikelvin. PMID:27801868
Measuring Total Column Water Vapor by Pointing an Infrared Thermometer at the Sky
NASA Technical Reports Server (NTRS)
Mims, Forrest M., III; Chambers, Lin H.; Brooks, David R.
2011-01-01
A 2-year study affirms that the temperature (Tz) indicated by an inexpensive ($20 to $60) IR thermometer pointed at the cloud-free zenith sky provides an approximate indication of the total column water vapor (precipitable water or PW). PW was measured by a MICROTOPS II sun photometer. The coefficient of correlation (r2) of the PW and Tz was 0.90, and the rms difference was 3.2 mm. A comparison of the Tz data with the PW provided by a GPS site 31 km NNE yielded an r2 of 0.79, and an rms difference of 5.8 mm. An expanded study compared Tz from eight IR thermometers with PW at various times during the day and night from 17 May to 18 October 2010, mainly at the Texas site and 10 days at Hawaii's Mauna Loa Observatory (MLO). The best results of this comparison were provided by two IR thermometers models that yielded an r2 of 0.96 and an rms difference with the PW of 2.7 mm. The results of both the ongoing 2-year study and the 5-month instrument comparison show that IR thermometers can measure PW with an accuracy (rms difference/mean PW) approaching 10%, the accuracy typically ascribed to sun photometers.
78 FR 54731 - Update to the List of Basic Medical Supplies
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-05
... Suture removal kits Syringes Thermometers, mercury for measuring human body temperature Tongue depressors... equipment Orthopedic traction devices and tables Human body positioners including pads, wedges, cradles... staples; and removal kits Tourniquets Thermometers for measuring human body temperature Clinical basins...
A Virtual Instrument Panel and Serial Interface for the Parr 1672 Thermometer
ERIC Educational Resources Information Center
Salter, Gail; Range, Kevin; Salter, Carl
2005-01-01
The various features of a Visual Basic Program, which implements the 1672 Parr thermometer are described. The program permits remote control of the calorimetry experiment and also provides control for the flow of data and for file storage.
A low-cost infrared thermometry system for use in research and production agriculture
USDA-ARS?s Scientific Manuscript database
Plant canopy temperature is used in many studies of plant/environment interactions. Non-contact measurement of plant canopy temperature is often accomplished through the use of radiometric surface thermometers commonly referred to as infrared thermometers. Industrial-quality infrared thermocouples a...
27 CFR 19.277 - Measuring devices and proofing instruments.
Code of Federal Regulations, 2010 CFR
2010-04-01
... provide for their own use accurate hydrometers, thermometers, and other necessary equipment to determine proof or volume. (b) Instruments. Hydrometers and thermometers used by proprietors to gauge spirits... those prescribed in 27 CFR part 30. Proprietors shall make frequent tests of their hydrometers and...
Meteorological Data for testing
1981-06-02
reading Rnadiosonde a2nd recorder Balloon Fluid-filled probe and soil Soil temperature: + 10 C thermograph, if required Thermometers and psychrometer ...Humidity. Ambient temperatures are measured by thermometers such as the ML/352/UM or by a psychrometer IL.-224 that gives wet and dry bulb temperatures of
Characteristics of Infrared Detectors for Spece Applications
2000-10-01
using Platinium Resistance Thermometers using the four lead method. The readout is performed by a high performace voltmeter, HP 3458 type. These...3.3.4 Temperature measurements The accuracy of the temperature measurements are mainly due to the Platinium Resistance Thermometers using the four lead
Radiation Requirements and Testing of Cryogenic Thermometers for the Ilc
NASA Astrophysics Data System (ADS)
Barnett, T.; Filippov, Yu. P.; Filippova, E. Yu.; Mokhov, N. V.; Nakao, N.; Klebaner, A. L.; Korenev, S. A.; Theilacker, J. C.; Trenikhina, J.; Vaziri, K.
2008-03-01
Large quantity of cryogenic temperature sensors will be used for operation of the International Linear Collider (ILC). Most of them will be subject to high radiation doses during the accelerator lifetime. Understanding of particle energy spectra, accumulated radiation dose in thermometers and its impact on performance are vital in establishing technical specification of cryogenic thermometry for the ILC. Realistic MARS15 computer simulations were performed to understand the ILC radiation environment. Simulation results were used to establish radiation dose requirements for commercially available cryogenic thermometers. Two types of thermometers, Cernox® and TVO, were calibrated prior to irradiation using different technique. The sensors were subjected then to up to 200 kGy electron beam irradiation with kinetic energy of 5 MeV, a representative of the situation at the ILC operation. A post-irradiation behavior of the sensors was studied. The paper describes the MARS15 model, simulation results, cryogenic test set-up, irradiation tests, and cryogenic test results.
Mimila-Arroyo, J
2017-06-01
In this paper, it is demonstrated that the free electron gas primary thermometer based on a bipolar junction transistor is able to provide the temperature with an accuracy of a few parts per million. Its simple functioning principle exploits the behavior of the collector current when properly biased to extract the temperature. Using general purpose silicon transistors at the water triple point (273.16 K) and gallium melting point (302.9146), an accuracy of a few parts per million has been reached, constituting the simplest and the easiest to operate primary thermometer, that might be considered even for the redefinition of Kelvin.
NASA Astrophysics Data System (ADS)
Mimila-Arroyo, J.
2017-06-01
In this paper, it is demonstrated that the free electron gas primary thermometer based on a bipolar junction transistor is able to provide the temperature with an accuracy of a few parts per million. Its simple functioning principle exploits the behavior of the collector current when properly biased to extract the temperature. Using general purpose silicon transistors at the water triple point (273.16 K) and gallium melting point (302.9146), an accuracy of a few parts per million has been reached, constituting the simplest and the easiest to operate primary thermometer, that might be considered even for the redefinition of Kelvin.
27 CFR 30.22 - Hydrometers and thermometers.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Hydrometers and... BUREAU, DEPARTMENT OF THE TREASURY LIQUORS GAUGING MANUAL Gauging Instruments § 30.22 Hydrometers and thermometers. The hydrometers used are graduated to read the proof of aqueous alcoholic solutions at 60 degrees...
A High-Resolution Thermometer for the Range 0.75-1.0 K
NASA Technical Reports Server (NTRS)
Panek, J.; Nash, A.; Larson, M.; Mulders, N.
1999-01-01
We report on a new high-resolution thermometer (HRT) for use near the tricritical point in 3He-4He mixtures. It is based on an existing HRT design that uses a DC-SQUID to detect the magnetization of a paramagnetic sensing element.
Poveda, Vanessa de Brito; Nascimento, Ariane de Souza
2016-01-01
To verify the correlation between temperature measurements performed using an infrared tympanic thermometer and an esophageal thermometer during the intraoperative period. A longitudinal study of repeated measures was performed including subjects aged 18 years or older undergoing elective oncologic surgery of the digestive system, with anesthesia duration of at least 1 hour. Temperature measurements were performed simultaneously by a calibrated esophageal thermometer and by a calibrated infrared tympanic thermometer, with laboratory reading precision of ±0.2ºC. The operating room temperature remained between 19 and 21ºC. The study included 51 patients, mostly men (51%), white (80.4%). All patients were kept warm by a forced-air heating system, for an average of 264.14 minutes (SD = 87.7). The two temperature measurements showed no different behavior over time (p = 0.2205), however, tympanic measurements were consistently 1.24°C lower (p<0.0001). The tympanic thermometer presented reliable results but reflected lower temperatures than the esophageal thermometer. Verificar a correlação entre as medidas de temperatura realizadas por meio de um termômetro timpânico por infravermelho e por um termômetro esofágico, durante o período intraoperatório. Realizou-se um estudo longitudinal, de medidas repetidas, incluindo sujeitos com idade igual ou superior a 18 anos, submetidos à cirurgia oncológica eletiva do sistema digestório, com duração da anestesia de, no mínimo, 1 hora. As medidas de temperatura eram realizadas, ao mesmo tempo, por meio de um termômetro esofágico calibrado e por termômetro timpânico por infravermelho calibrado, com precisão de leitura em laboratório de ±0,2ºC. A temperatura da sala operatória permaneceu entre 19 e 21ºC. Foram incluídos 51 pacientes, em sua maioria homens (51%), brancos (80,4%). Todos os pacientes foram aquecidos com o sistema de ar forçado aquecido, em média por 264,14 minutos (DP = 87,7). As duas medidas de temperatura não tiveram comportamento diferente ao longo do tempo (p = 0,2205), mas a medida timpânica foi consistentemente menor em 1,24°C (p < 0,0001). O termômetro timpânico apresentou resultados confiáveis, mas refletiu temperaturas mais baixas do que o termômetro esofágico.
Aadal, Lena; Fog, Lisbet; Pedersen, Asger Roer
2016-12-01
Investigation of a possible relation between body temperature measurements by the current generation of tympanic ear and rectal thermometers. In Denmark, a national guideline recommends the rectal measurement. Subsequently, the rectal thermometers and tympanic ear devices are the most frequently used and first choice in Danish hospital wards. Cognitive changes constitute challenges with cooperating in rectal temperature assessments. With regard to diagnosing, ethics, safety and the patients' dignity, the tympanic ear thermometer might comprise a desirable alternative to rectal noninvasive measurement of body temperature during in-hospital-based neurorehabilitation. A prospective, descriptive cohort study. Consecutive inclusion of 27 patients. Linear regression models were used to analyse 284 simultaneous temperature measurements. Ethical approval for this study was granted by the Danish Data Protection Agency, and the study was completed in accordance with the Helsinki Declaration 2008. About 284 simultaneous rectal and ear temperature measurements on 27 patients were analysed. The patient-wise variability of measured temperatures was significantly higher for the ear measurements. Patient-wise linear regressions for the 25 patients with at least three pairs of simultaneous ear and rectal temperature measurements showed large interpatient variability of the association. A linear relationship between the rectal body temperature assessment and the temperature assessment employing the tympanic thermometer is weak. Both measuring methods reflect variance in temperature, but ear measurements showed larger variation. © 2016 Nordic College of Caring Science.
Calibration of Radiation Thermometers up to : Effective Emissivity of the Source
NASA Astrophysics Data System (ADS)
Kozlova, O.; Briaudeau, S.; Rongione, L.; Bourson, F.; Guimier, S.; Kosmalski, S.; Sadli, M.
2015-08-01
The growing demand of industry for traceable temperature measurements up to encourages improvement of calibration techniques for industrial-type radiation thermometers in this temperature range. High-temperature fixed points can be used at such high temperatures, but due to the small diameter of apertures of their cavities (3 mm), they are not adapted for the large field-of-views commonly featured by this kind of radiation thermometers. At LNE-Cnam, a Thermo Gauge furnace of 25.4 mm source aperture diameter is used as a comparison source to calibrate customers' instruments against a reference radiation thermometer calibrated according to the ITS-90 with the lowest uncertainties achievable in the Laboratory. But the furnace blackbody radiator exhibits a large temperature gradient that degrades its effective emissivity, and increases the calibration uncertainty due to the lack of information on the working spectral band of the industrial radiation thermometer. In order to estimate the corrections to apply, the temperature distribution (radial and on-axis) of the Thermo Gauge furnace blackbody radiator was characterized and the effective emissivity of the Thermo Gauge cavity was determined by three different methods. Because of this investigation, the corrections due to different fields of view and due to the different spectral bands of the reference pyrometer and the customer's pyrometer were obtained and the uncertainties on these corrections were evaluated.
Make Your Own Digital Thermometer!
ERIC Educational Resources Information Center
Sorey, Timothy; Willard, Teri; Kim, Bom
2010-01-01
In the hands-on, guided-inquiry lesson presented in this article, high school students create, calibrate, and apply an affordable scientific-grade instrument (Lapp and Cyrus 2000). In just four class periods, they build a homemade integrated circuit (IC) digital thermometer, apply a math model to calibrate their instrument, and ask a researchable…
21 CFR 880.2900 - Clinical color change thermometer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Clinical color change thermometer. 880.2900 Section 880.2900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use...
21 CFR 880.2900 - Clinical color change thermometer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Clinical color change thermometer. 880.2900 Section 880.2900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use...
21 CFR 880.2900 - Clinical color change thermometer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Clinical color change thermometer. 880.2900 Section 880.2900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use...
21 CFR 880.2900 - Clinical color change thermometer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Clinical color change thermometer. 880.2900 Section 880.2900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use...
Uchiyama, Seiichi; Tsuji, Toshikazu; Kawamoto, Kyoko; Okano, Kentaro; Fukatsu, Eiko; Noro, Takahiro; Ikado, Kumiko; Yamada, Sayuri; Shibata, Yuka; Hayashi, Teruyuki; Inada, Noriko; Kato, Masaru; Koizumi, Hideki; Tokuyama, Hidetoshi
2018-05-04
A cationic fluorescent nanogel thermometer based on thermo-responsive N-isopropylacrylamide and environment-sensitive benzothiadiazole was developed with a new azo compound bearing imidazolium rings as the first cationic radical initiator. This cationic fluorescent nanogel thermometer showed an excellent ability to enter live mammalian cells in a short incubation period (10 min), a high sensitivity to temperature variations in live cells (temperature resolution of 0.02-0.84 °C in the range 20-40 °C), and remarkable non-cytotoxicity, which permitted ordinary cell proliferation and even differentiation of primary cultured cells. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Study on the laser irradiation characteristics of NEPE propellant in different oxygen concentrations
NASA Astrophysics Data System (ADS)
Xiang, Hengsheng; Chen, Xiong; Zhou, Changsheng
2016-01-01
The ignition and combustion characteristics of nitrate ester plasticized polyether (NEPE) propellant in different oxygen concentrations ambient gases were studied by the application of CO2 laser, infrared thermometer and high speed camera. The flame intensity data of the propellant was collected by the photodiode; propellant flame temperature was measured by infrared thermometer. The experimental results show that the time which NEPE propellant spend to be stable combustion will get shorter with the increase of oxygen concentration; the flame peak temperature measured by infrared thermometer increases with the increase of oxygen concentration when the oxygen concentration is less than 30% by volume, then decreases with the increase of oxygen concentration.
Using an Infrared Thermometer for Solar Pyranometry
ERIC Educational Resources Information Center
Fiedler, B. H.
2011-01-01
The simple hand-held infrared thermometer can be used to measure the temperature of surfaces of different reflectivity exposed to sunlight and wind. From four temperature measurements of black and white panels in windy and wind-sheltered conditions, together with the two wind speed measurements, both the flux of incident solar radiation and the…
Science, Technology and Society--An Authentic Exploration of IR Thermometers Application in Schools
ERIC Educational Resources Information Center
Tse, Isaac Pak Hoi; Leung, Winston Kwok Kuen; Chan, Shing Yi
2004-01-01
"Science, Technology and Society" was identified an essential strand in the new Science Education curriculum guide. Shortly after the severe acute respiratory syndrome (SARS) threat to Hong Kong technical dealers introduced Infrared non-contact thermometers as a solution for schools to measure body temperature for a large number of…
Yan, Qiang; Yuan, Jinying; Kang, Yan; Cai, Zhinan; Zhou, Lilin; Yin, Yingwu
2010-04-28
A porphyrin-containing copolymer has dual-sensing in response to metal ions and temperature as a novel nanosensor. Triggered by ions, the sensor exhibits full-color tunable behavior as a cationic detector and colorimeter. Responding to temperature, the sensor displays an "isothermal" thermochromic point as an ultra-sensitive thermometer.
RuO2 Thermometer for Ultra-Low Temperatures
NASA Technical Reports Server (NTRS)
Hait, Thomas; Shirron, Peter J.; DiPirro, Michael
2009-01-01
A small, high-resolution, low-power thermometer has been developed for use in ultra-low temperatures that uses multiple RuO2 chip resistors. The use of commercially available thick-film RuO2 chip resistors for measuring cryogenic temperatures is well known due to their low cost, long-term stability, and large resistance change.
ERIC Educational Resources Information Center
Ucke, C.; Schlichting, H. J.
2017-01-01
This relatively rare thermometer has a rather unusual display: lower temperatures are located at the top of the scale, higher ones at the bottom. A sphere on a chain floats in a suitable liquid, sinking at high temperatures when the density of the liquid decreases and rising in the increased density at low temperatures. With reasonable effort and…
Ingestible Thermometer Pill Aids Athletes in Beating the Heat
NASA Technical Reports Server (NTRS)
2006-01-01
Developed by Goddard Space Flight Center and the Johns Hopkins University Applied Physics Laboratory to monitor the core body temperature of astronauts during space flight, the ingestible "thermometer pill" has a silicone-coated exterior, with a microbattery, a quartz crystal temperature sensor, a space-aged telemetry system, and microminiaturized circuitry on the interior.
Corrections on the Thermometer Reading in an Air Stream
NASA Technical Reports Server (NTRS)
Van Der Maas, H J; Wynia, S
1940-01-01
A method is described for checking a correction formula, based partly on theoretical considerations, for adiabatic compression and friction in flight tests and determining the value of the constant. It is necessary to apply a threefold correction to each thermometer reading. They are a correction for adiabatic compression, friction and for time lag.
APMP Scale Comparison with Three Radiation Thermometers and Six Fixed-Point Blackbodies
NASA Astrophysics Data System (ADS)
Yamada, Y.; Shimizu, Y.; Ishii, J.
2015-08-01
New Asia Pacific Metrology Programme (APMP) comparisons of radiation thermometry standards, APMP TS-11, and -12, have recently been initiated. These new APMP comparisons cover the temperature range from to . Three radiation thermometers with central wavelengths of 1.6 , 0.9 , and 0.65 are the transfer devices for the radiation thermometer scale comparison conducted in the so-called star configuration. In parallel, a compact fixed-point blackbody furnace that houses six types of fixed-point cells of In, Sn, Zn, Al, Ag, and Cu is circulated, again in a star-type comparison, to substantiate fixed-point calibration capabilities. Twelve APMP national metrology institutes are taking part in this endeavor, in which the National Metrology Institute of Japan acts as the pilot. In this article, the comparison scheme is described with emphasis on the features of the transfer devices, i.e., the radiation thermometers and the fixed-point blackbodies. Results of preliminary evaluations of the performance and characteristic of these instruments as well as the evaluation method of the comparison results are presented.
Kartoğlu, Umit; Nelaj, Erida; Maire, Denis
2010-05-28
This intervention study was conducted in Albania to establish the superiority of the Fridge-tag (30-day electronic refrigerator temperature logger) against thermometers. Intervention sites used Fridge-tag and a modified temperature control record sheet, while control sites continued with their routine operation with thermometers. All refrigerators in both groups were equipped with downloadable electronic data loggers to record temperatures for reference. Focus group sessions were conducted with involved staff to discuss temperature monitoring, Fridge-tag use and its user-friendliness. Significant discrepancies were observed between thermometer readings and the electronic data loggers in control sites, while all alarms from Fridge-tag were confirmed in the intervention group. Thermometers are not sufficient to monitor temperatures in refrigerators since they miss the great majority of low and high alarms. Fridge-tag has proven to be an effective tool in providing health workers with the information they need to take the necessary actions when there are refrigerator temperature variations. (c) 2010 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Y., E-mail: zhangya@iis.u-tokyo.ac.jp; Watanabe, Y.; Hosono, S.
We propose a room temperature, all electrical driving and detecting, very sensitive thermometer structure using a microelectromechanical (MEMS) resonator for bolometer applications. We have fabricated a GaAs doubly clamped MEMS beam resonator whose oscillation can be excited and detected by the piezoelectric effect. When a heating power is applied to a NiCr film deposited on the MEMS beam surface, internal thermal stress is generated in the beam, leading to a reduction in the resonance frequency. The present device detects the shift in the resonance frequency caused by heating and works as a very sensitive thermometer. When the resonator was drivenmore » by a voltage slightly below the threshold for the nonlinear, hysteretic oscillation, the thermometer showed a voltage responsivity of about 3300 V/W, while keeping a low noise spectral density of about 60 nV/Hz{sup 1/2}, demonstrating a noise equivalent power of <20 pW/Hz{sup 1/2} even at room temperature. The observed effect can be used for realizing high-sensitivity terahertz bolometers for room-temperature operation.« less
Electrical and Infrared Optical Properties of Vanadium Oxide Semiconducting Thin-Film Thermometers
NASA Astrophysics Data System (ADS)
Zia, Muhammad Fakhar; Abdel-Rahman, Mohamed; Alduraibi, Mohammad; Ilahi, Bouraoui; Awad, Ehab; Majzoub, Sohaib
2017-10-01
A synthesis method has been developed for preparation of vanadium oxide thermometer thin film for microbolometer application. The structure presented is a 95-nm thin film prepared by sputter-depositing nine alternating multilayer thin films of vanadium pentoxide (V2O5) with thickness of 15 nm and vanadium with thickness of 5 nm followed by postdeposition annealing at 300°C in nitrogen (N2) and oxygen (O2) atmospheres. The resulting vanadium oxide (V x O y ) thermometer thin films exhibited temperature coefficient of resistance (TCR) of -3.55%/°C with room-temperature resistivity of 2.68 Ω cm for structures annealed in N2 atmosphere, and TCR of -3.06%/°C with room-temperature resistivity of 0.84 Ω cm for structures annealed in O2 atmosphere. Furthermore, optical measurements of N2- and O2-annealed samples were performed by Fourier-transform infrared ellipsometry to determine their dispersion curves, refractive index ( n), and extinction coefficient ( k) at wavelength from 7000 nm to 14,000 nm. The results indicate the possibility of applying the developed materials in thermometers for microbolometers.
Lefrant, J-Y; Muller, L; de La Coussaye, J Emmanuel; Benbabaali, M; Lebris, C; Zeitoun, N; Mari, C; Saïssi, G; Ripart, J; Eledjam, J-J
2003-03-01
Comparisons of urinary bladder, oesophageal, rectal, axillary, and inguinal temperatures versus pulmonary artery temperature. Prospective cohort study. Intensive Care Unit of a University-Hospital. Forty-two intensive care patients requiring a pulmonary artery catheter (PAC). Patients requiring PAC and without oesophageal, urinary bladder, and/or rectal disease or recent surgery were included in the study. Temperature was simultaneously monitored with PAC, urinary, oesophageal, and rectal electronic thermometers and with axillary and inguinal gallium-in-glass thermometers. Comparisons used a Bland and Altman method. The pulmonary arterial temperature ranged from 33.7 degrees C to 40.2 degrees C. Urinary bladder temperature was assessed in the last 22 patients. A total of 529 temperature measurement comparisons were carried out (252 comparisons of esophageal, rectal, inguinal, axillary, and pulmonary artery temperature measurements in the first 20 patients, and 277 comparisons with overall methods in the last patients). Nine to 18 temperature measurement comparisons were carried out per patient (median = 13). The mean differences between pulmonary artery temperatures and those of the different methods studied were: oesophageal (0.11+/-0.30 degrees C), rectal (-0.07+/-0.40 degrees C), axillary (0.27+/-0.45 degrees C), inguinal (0.17+/-0.48 degrees C), urinary bladder (-0.21+/-0.20 degrees C). In critically ill patients, urinary bladder and oesophageal electronic thermometers are more reliable than the electronic rectal thermometer which is better than inguinal and axillary gallium-in-glass thermometers to measure core temperature.
NASA Astrophysics Data System (ADS)
Khrit, N. G.; Alghoul, M. A.; Sopian, K.; Lahimer, A. A.; Elayeb, O. K.
2017-11-01
Assessing outdoor human thermal comfort and urban climate quality require experimental investigation of microclimatic conditions and their variations in open urban spaces. For this, it is essential to provide quantitative information on air temperature, humidity, wind velocity and mean radiant temperature. These parameters can be quantified directly except mean radiant temperature (Tmrt). The most accurate method to quantify Tmrt is integral radiation measurements (3-D shortwave and long-wave) which require using expensive radiometer instruments. To overcome this limitation the well-known globe thermometer method was suggested to calculate Tmrt. The aim of this study was to assess the possibility of using indoor globe thermometer method in predicting outdoor mean radiant temperature under Malaysia tropical microclimate. Globe thermometer method using small and large sizes of black-painted copper globes (50mm, 150mm) were used to estimate Tmrt and compare it with the reference Tmrt estimated by integral radiation method. The results revealed that the globe thermometer method considerably overestimated Tmrt during the middle of the day and slightly underestimated it in the morning and late evening. The difference between the two methods was obvious when the amount of incoming solar radiation was high. The results also showed that the effect of globe size on the estimated Tmrt is mostly small. Though, the estimated Tmrt by the small globe showed a relatively large amount of scattering caused by rapid changes in radiation and wind speed.
Comparison of infrared thermometer with thermocouple for monitoring skin temperature.
Matsukawa, T; Ozaki, M; Nishiyama, T; Imamura, M; Kumazawa, T
2000-02-01
To test the hypothesis that the infrared thermometer (Genius) is comparably useful with thermocouples that are routinely used for skin temperature monitoring. Prospective, controlled, not blinded study. Operating room of a university hospital. Ten healthy male volunteers. Volunteers were minimally clothed and were initially warmed by a forced air warmer until they became vasodilated at the finger and the foot for approximately 30 mins. Subsequently, they were kept in the room with no blanket. Skin temperatures were measured continuously with the Mon-a-Therm thermocouple and were also measured with the Genius thermometer just before and after the warming and subsequently every 10 mins for 70 mins. Forearm and finger-tip skin temperatures and skin-surface temperature gradients (from arm to finger and from calf to toe) measured by the Genius thermometer were compared with those measured by the Mon-a-Therm thermocouple using linear regression and Bland and Altman statistics. Forearm temperature and finger-tip temperature ranged from approximately 31 degrees to approximately 36.5 degrees C (87.8-97.7 degrees F) and approximately 22.5 degrees to approximately 36 degrees C (72.5-96.8 degrees F), respectively. Gradients (from arm to finger and from calf to toe) ranged from approximately -3 degrees to approximately 10 degrees C (26.6-50.0 degrees F) and approximately -3 degrees to approximately 11 degrees C (26.6-51.8 degrees F), respectively. Correlations between the temperatures measured by the Genius thermometer and those by the Mon-a-Therm thermocouple were similar and reliable. The correlation coefficients were as follows: 0.78 at forearm, 0.97 at finger-tip, and 0.97 at skin-surface temperature gradients. The infrared thermometer with a special probe is useful to measure the change of skin-surface temperatures and to evaluate the severity of shock in patients.
[Measurement of tympanic temperature by infrared and thermocouple thermometry. A comparative study].
Nathan, N; Guillaume, A; Feiss, P
1995-01-01
To compare tympanic temperatures obtained with an infrared thermometer Core Check 2090A (IVAC), non in contact with the tympanic membrane, to values obtained with a thermocouple thermometer Mon-A-Therm (Mallinckrodt) in contact with it, and to assess whether the differences depend on the person measuring the temperature. Prospective comparative open study. The study included 150 adults in whom the tympanic temperatures were measured at their admission to recovery room by 10 nurse anaesthetists. Each thermometer was inserted in the same patient into an external acoustic meatus. The median and range of the temperature differences were used to assess the bias and the accuracy of the measures. Their reliability was analyzed with consideration of the measuring person and the presence of irrelevant values, defined as a temperature difference over 0.3 degrees C. The temperatures obtained with both devices were similar (36.2 +/- 0.7 degrees C with IVAC thermometer vs 36.2 +/- 0.8 degrees C with Mallinckrodt thermometer). The median value of the differences was 0 degrees C, with a range of 2.5 degrees C (maximum value + 1.5 degrees C, minimum value: -1 degree C). Nineteen patients could be qualified as hypothermic (temperature < 36.5 degrees C) with one thermometer and normothermic (temperature > or = 36.5 degrees C) with the other. Among them, only 9 (6%) had temperature differences above 0.3 degrees C. The temperature differences were not different according to the measuring nurse. Nevertheless two of them obtained major differences or irrelevant figures. As compared to the thermocouple thermometry, infrared thermometry has no bias but a low precision. The measurement error does not allow the recognition of hypothermia in 6% of patients. The error may be made by the measuring person and/or related to the anatomy and the patency of the external acoustic meatus. Tympanic infrared thermometry seems to be a convenient method for temperature measurements at short time intervals in the recovery room, provided its limitations are kept in mind.
Very Fast Temperature Measurement with a Thin Lamp Filament
ERIC Educational Resources Information Center
G. Calza, Gratton, L. M.; Lopez-Arias, T.; Oss, S.
2012-01-01
We construct a thermometer exploiting the electric resistance of the filament of a small lamp used in micro-illumination settings. The instrument may guarantee a response time better than 10 ms, i.e. much faster than commercial thermocouples or other quite expensive devices. This makes our thermometer a useful one in several processes which are…
In-situ technique for checking the calibration of platinum resistance thermometers
NASA Technical Reports Server (NTRS)
Daryabeigi, Kamran; Dillon-Townes, Lawrence A.
1987-01-01
The applicability of the self-heating technique for checking the calibration of platinum resistance thermometers located inside wind tunnels was investigated. This technique is based on a steady state measurement of resistance increase versus joule heating. This method was found to be undesirable, mainly because of the fluctuations of flow variables during any wind tunnel testing.
Software Products for Temperature Data Reduction of Platinum Resistance Thermometers (PRT)
NASA Technical Reports Server (NTRS)
Sherrod, Jerry K.
1998-01-01
The main objective of this project is to create user-friendly personal computer (PC) software for reduction/analysis of platinum resistance thermometer (PRT) data. Software products were designed and created to help users of PRT data with the tasks of using the Callendar-Van Dusen method. Sample runs are illustrated in this report.
Time-Lapse and Slow-Motion Tracking of Temperature Changes: Response Time of a Thermometer
ERIC Educational Resources Information Center
Moggio, L.; Onorato, P.; Gratton, L. M.; Oss, S.
2017-01-01
We propose the use of a smartphone based time-lapse and slow-motion video techniques together with tracking analysis as valuable tools for investigating thermal processes such as the response time of a thermometer. The two simple experimental activities presented here, suitable also for high school and undergraduate students, allow one to measure…
Wilson, W B; Haus, A G; Nierman, C; Lillie, R; Batz, T; Moore, R
1993-01-01
In medical imaging, the temperature of the developer solution in the film processor affects film speed (radiation dose), film contrast, and film base plus fog. The National Council on Radiation Protection and Measurement (NCRP) Report 99 on Quality Assurance, and the American College of Radiology (ACR) Mammography Quality Control Manual for Radiologic Technologists, indicate that the developer temperature should be within +/- 0.5 degree F (+/- 0.3 degree C) of that recommended by the manufacturer for the specific film/developer combination being used. The accuracy and repeatability of the thermometer is most important. This paper describes the requirements of a thermometer for measuring the temperature of the developer solution and suggests an inexpensive but accurate device for doing so.
Sensors, Volume 4, Thermal Sensors
NASA Astrophysics Data System (ADS)
Scholz, Jorg; Ricolfi, Teresio
1996-12-01
'Sensors' is the first self-contained series to deal with the whole area of sensors. It describes general aspects, technical and physical fundamentals, construction, function, applications and developments of the various types of sensors. This volume describes the construction and applicational aspects of thermal sensors while presenting a rigorous treatment of the underlying physical principles. It provides a unique overview of the various categories of sensors as well as of specific groups, e.g. temperature sensors (resistance thermometers, thermocouples, and radiation thermometers), noise and acoustic thermometers, heat-flow and mass-flow sensors. Specific facettes of applications are presented by specialists from different fields including process control, automotive technology and cryogenics. This volume is an indispensable reference work and text book for both specialists and newcomers, researchers and developers.
Silicon-based Coulomb blockade thermometer with Schottky barriers
NASA Astrophysics Data System (ADS)
Tuboltsev, V.; Savin, A.; Rogozin, V. D.; Räisänen, J.
2014-04-01
A hybrid Coulomb blockade thermometer (CBT) in form of an array of intermittent aluminum and silicon islands connected in series via tunnel junctions was fabricated on a thin silicon-on-insulator (SOI) film. Tunnel barriers in the micrometer size junctions were formed by metal-semiconductor Schottky contacts between aluminium electrodes and heavily doped silicon. Differential conductance through the array vs. bias voltage was found to exhibit characteristic features of competing thermal and charging effects enabling absolute temperature measurements over the range of ˜65 to ˜500 mK. The CBT performance implying the primary nature of the thermometer demonstrated for rather trivial architecture attempted in this work paves a route for introduction of Coulomb blockade thermometry into well-developed contemporary SOI technology.
NASA Astrophysics Data System (ADS)
Pal, Sandip; Kar, Ranjan; Mandal, Anupam; Das, Ananda; Saha, Subrata
2017-05-01
A prototype of a variable temperature insert has been developed in-house as a cryogenic thermometer calibration facility. It was commissioned in fulfilment of the very stringent requirements of the temperature control of the cryogenic system. The calibration facility is designed for calibrating industrial cryogenic thermometers that include a temperature sensor and the wires heat-intercept in the 2.2 K-325 K temperature range. The isothermal section of the calibration block onto which the thermometers are mounted is weakly linked with the temperature control zone mounted with cooling capillary coil and cryogenic heater. The connecting wires of the thermometer are thermally anchored with the support of the temperature insert. The calibration procedure begins once the temperature of the support is stabilized. Homogeneity of the calibration block’s temperature is established both by simulation and by cross-comparison of two calibrated sensors. The absolute uncertainty present in temperature measurement is calculated and found comparable with the measured uncertainty at different temperature points. Measured data is presented in comparison to the standard thermometers at fixed points and it is possible to infer that the absolute accuracy achieved is better than ±0.5% of the reading in comparison to the fixed point temperature. The design and development of simpler, low cost equipment, and approach to analysis of the calibration results are discussed further in this paper, so that it can be easily devised by other researchers.
Code of Federal Regulations, 2014 CFR
2014-01-01
... following: a. A thermopile b. Calibrated resistance thermometers c. Precision thermometers d. Calibrated... is used, it shall be made from calibrated thermocouple wire taken from a single spool. Extension wires to the recording device shall also be made from that same spool. 3.2.6 Time Constant. The time...
Development of a Standard Platinum Resistance Thermometer for Use up to the Copper Point
NASA Astrophysics Data System (ADS)
Tavener, J. P.
2015-08-01
The international temperature scale of 1990 defines temperatures in the range from 13.8 K to 1234.93 K () using a standard platinum resistance thermometer (SPRT) as an interpolating instrument. For temperatures above , the current designs of an SPRT require extreme care to avoid contamination, especially by metallic impurities, which can cause rapid and irreversible drift. This study investigates the performance of a new design of a high-temperature SPRT with the aim of improving the stability of the SPRTs and extending their temperature range. The prototype SPRTs have an alumina sheath, a sapphire support for the sensing element, which are aspirated with dry air and operated with a dc bias voltage to suppress the diffusion of metal-ion contaminants. Three prototype thermometers were exposed to temperatures near or above the copper freezing point, , for total exposure times in excess of 500 h and exhibited drifts in the triple-point resistance of less than 10 mK. The new design eliminates some of the problems associated with fused-silica sheaths and sensor-support structures and is a viable option for a high-accuracy thermometer for temperatures approaching.
Programmable Quantitative DNA Nanothermometers.
Gareau, David; Desrosiers, Arnaud; Vallée-Bélisle, Alexis
2016-07-13
Developing molecules, switches, probes or nanomaterials that are able to respond to specific temperature changes should prove of utility for several applications in nanotechnology. Here, we describe bioinspired strategies to design DNA thermoswitches with programmable linear response ranges that can provide either a precise ultrasensitive response over a desired, small temperature interval (±0.05 °C) or an extended linear response over a wide temperature range (e.g., from 25 to 90 °C). Using structural modifications or inexpensive DNA stabilizers, we show that we can tune the transition midpoints of DNA thermometers from 30 to 85 °C. Using multimeric switch architectures, we are able to create ultrasensitive thermometers that display large quantitative fluorescence gains within small temperature variation (e.g., > 700% over 10 °C). Using a combination of thermoswitches of different stabilities or a mix of stabilizers of various strengths, we can create extended thermometers that respond linearly up to 50 °C in temperature range. Here, we demonstrate the reversibility, robustness, and efficiency of these programmable DNA thermometers by monitoring temperature change inside individual wells during polymerase chain reactions. We discuss the potential applications of these programmable DNA thermoswitches in various nanotechnology fields including cell imaging, nanofluidics, nanomedecine, nanoelectronics, nanomaterial, and synthetic biology.
Development of a 300 L Calibration Bath for Oceanographic Thermometers
NASA Astrophysics Data System (ADS)
Baba, S.; Yamazawa, K.; Nakano, T.; Saito, I.; Tamba, J.; Wakimoto, T.; Katoh, K.
2017-11-01
The Japan Agency for Marine-Earth Science and Technology (JAMSTEC) has been developing a 300 L calibration bath to calibrate 24 oceanographic thermometers (OT) simultaneously and thereby reduce the calibration work load necessary to service more than 180 OT every year. This study investigated characteristics of the developed 300 L calibration bath using a SBE 3plus thermometer produced by an OT manufacturer. We also used 11 thermistor thermometers that were calibrated to be traceable to the international temperature scale of 1990 (ITS-90) within 1 mK of standard uncertainty through collaboration of JAMSTEC and NMIJ/AIST. Results show that the time stability of temperature of the developed bath was within ± 1 mK. Furthermore, the temperature uniformity was ± 1.3 mK. The expanded uncertainty (k=2) components for the characteristics of the developed 300 L calibration bath were estimated as 2.9 mK, which is much less than the value of 10 mK: the required specification for uncertainty of calibration for the OT. These results demonstrated the utility of this 300 L calibration bath as a device for use with a new calibration system.
Protecting the Public From Mercury Exposure: Success Through Microexchange Events
Shoemaker, Paul A.; Ghaemghami, Jalal
2003-01-01
Mercury is a growing environmental threat that can cause serious health problems and birth defects. Household thermometers are high-risk sources of mercury because most people lack the knowledge to properly dispose of one when it is broken. The Boston Public Health Commission’s Environmental Health Office, with local and national partners, created the Boston Mercury Thermometer Exchange Program to address this hazard. Large central exchanges are successful, but multiple smaller targeted “microexchanges” can be another effective way to reach the general public and specific vulnerable subpopulations such as the elderly, the homebound disabled, or recent immigrants. By conducting exchanges in community health centers and public housing developments for the elderly and disabled, and by working through home health care providers, the program collected 4477 thermometers. PMID:14652320
Noninvasive and Real-Time Plasmon Waveguide Resonance Thermometry
Zhang, Pengfei; Liu, Le; He, Yonghong; Zhou, Yanfei; Ji, Yanhong; Ma, Hui
2015-01-01
In this paper, the noninvasive and real-time plasmon waveguide resonance (PWR) thermometry is reported theoretically and demonstrated experimentally. Owing to the enhanced evanescent field and thermal shield effect of its dielectric layer, a PWR thermometer permits accurate temperature sensing and has a wide dynamic range. A temperature measurement sensitivity of 9.4 × 10−3 °C is achieved and the thermo optic coefficient nonlinearity is measured in the experiment. The measurement of water cooling processes distributed in one dimension reveals that a PWR thermometer allows real-time temperature sensing and has potential to be applied for thermal gradient analysis. Apart from this, the PWR thermometer has the advantages of low cost and simple structure, since our transduction scheme can be constructed with conventional optical components and commercial coating techniques. PMID:25871718
On-and-off chip cooling of a Coulomb blockade thermometer down to 2.8 mK
NASA Astrophysics Data System (ADS)
Palma, M.; Scheller, C. P.; Maradan, D.; Feshchenko, A. V.; Meschke, M.; Zumbühl, D. M.
2017-12-01
Cooling nanoelectronic devices below 10 mK is a great challenge since thermal conductivities become very small, thus creating a pronounced sensitivity to heat leaks. Here, we overcome these difficulties by using adiabatic demagnetization of both the electronic leads and the large metallic islands of a Coulomb blockade thermometer. This reduces the external heat leak through the leads and also provides on-chip refrigeration, together cooling the thermometer down to 2.8 ± 0.1 mK. We present a thermal model which gives a good qualitative account and suggests that the main limitation is heating due to pulse tube vibrations. With better decoupling, temperatures below 1 mK should be within reach, thus opening the door for μK nanoelectronics.
Infrared Skin Thermometry: Validating and Comparing Techniques to Detect Periwound Skin Infection.
Mufti, Asfandyar; Somayaji, Ranjani; Coutts, Patricia; Sibbald, R Gary
2018-01-01
Diagnosis of wound infection can be challenging because it relies on a combination of clinical signs and symptoms that are often nonspecific. Increased periwound cutaneous temperature is a classic sign of deep and surrounding wound infection, and its quantitative measurement is one of the most reliable and valid clinical signs of deep and surrounding skin infection at the bedside. Skin surface temperature differences may be detected using commercially available noncontact infrared thermometers. However, techniques to detect temperature using noncontact infrared thermometers vary, and no studies have evaluated these methods. Two such measurement techniques include the "4-point" and "whole-wound" scanning methods. This study assessed the ability of different infrared thermometers using the aforementioned techniques to detect clinically meaningful differences in periwound cutaneous temperatures used in the diagnosis of wound infection. A prospective cohort study was conducted from 2015 to 2016 of consenting adult patients 18 years or older with an open wound attending a regional wound care clinic. One hundred patients with wounds underwent surface temperature measurement. Infection was not a specific inclusion criterion as the primary objective was to conduct a comparative assessment of infrared thermometry devices. Demographic data (age, height, weight, gender, and ethnicity) were also collected. Each wound was measured using 4 different noncontact infrared thermometers: Exergen DermaTemp 1001 (Exergen Corporation, Watertown, Massachusetts), Mastercraft Digital Temperature Reader (Mastercraft, Toronto, Ontario, Canada), Mastercool MSC52224-A (Mastercool Inc, Randolph, New Jersey), and Etekcity ETC-8250 Temperature Heat Pen (Etekcity, Anaheim, California). Data analysis was based on a comparison of 4 periwound skin surface temperature measurement differences (ΔT in degrees Fahrenheit) between the wound site and an equivalent contralateral control site. The primary outcome of the ability of each thermometer to detect a clinically significant difference in temperature was assessed with χ analysis. Paired t tests were conducted to compare the ΔT measurements of each specific thermometry device between the 2 measurement techniques. Pearson product moment correlation coefficients were calculated for the temperature ΔT for both measuring techniques for all devices to determine level of agreement. A 1-way analysis of variance was conducted to compare temperature measurements among the infrared thermometry devices. There was no significant difference in the ability of each thermometer to detect a clinically meaningful difference of 3° F by either the 4-point (P = .10) or whole-wound techniques (P = .67). When a definition of 4° F was used, results were similar (4-point, P = .15; whole wound, P = .20). Comparisons among devices and techniques showed strong correlations (>0.80). Etekcity ETC-8250 and the 4-point measurement compared with the Exergen device using the whole-wound technique had a correlation coefficient of 0.72. Spearman ρ demonstrated a similarly high degree of correlation between techniques and devices, and only the Etekcity ETC-8250 device had a coefficient of 0.71 to 0.90 when compared with others. Paired t testing for each thermometry device comparing measurement techniques for raw temperatures ΔT demonstrated no significant difference (P > .05). No statistical differences among the ΔT values for the 3 different thermometers were noted when using the whole-wound method (P = .095). Similarly, no significant differences among the ΔT values were noted for the 4 different thermometers when using the 4-point method (P = .10). The results of this study demonstrate that both the 4-point and whole-wound methods of temperature acquisition using cost-efficient infrared thermometers provide accurate and similar results in clinical wound care settings.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations Documents and Cargo Information § 153.908... sensor or thermometer required by § 153.440(a)(3) or (c). If a portable thermometer is used, it must be located as prescribed for the temperature sensor in § 153.440(a)(3). (2) A total of 2 readings must be...
Code of Federal Regulations, 2011 CFR
2011-10-01
..., LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations Documents and Cargo Information § 153.908... sensor or thermometer required by § 153.440(a)(3) or (c). If a portable thermometer is used, it must be located as prescribed for the temperature sensor in § 153.440(a)(3). (2) A total of 2 readings must be...
Thermometers and thermobarometers in granitic systems
Anderson, J.L.; Barth, A.P.; Wooden, J.L.; Mazdab, F.; ,
2008-01-01
The ability to determine the thermal and barometric history during crystallization and emplacement of granitic plutons has been enhanced by several new calibrations applicable to granitic mineral assemblages. Other existing calibrations for granitic plutons have continued to be popular and fairly robust. Recent advances include the trace element thermometers Ti-in-quartz, Ti-in-zircon, and Zr-in-sphene (titanite), which need to be further evaluated on the roles of reduced activities due to lack of a saturating phase, the effect of pressure dependence (particularly for the Ti-in-zircon thermometer), and how resistive these thermometers are to subsolidus reequilibration. As zircon and sphene are also hosts to radiogenic isotopes, these minerals potentially also provide new insights into the temperature - time history of magmas. When used in conjunction with pressure-sensitive mineral equilibria in the same rocks, a complete assessment of the P-T-t (pressure-temperature-time) path is possible given that the mineralogy of plutons can reflect crystallization over a range of pressure and temperature during ascent and emplacement and that many intrusions are now seen as forming over several millions of years during the protracted history of batholith construction. Accessory mineral saturation thermometers, such as those for zircon, apatite, and allanite, provide a different and powerful perspective, specifically that of the temperature of the onset of crystallization of these minerals, which can allow an estimate of the range of temperature between the liquidus and solidus of a given pluton. In assessment of the depth of crystallization and emplacement of granitic plutons, the Al-in-hornblende remains popular for metaluminous granites when appropriately corrected for temperature. For peraluminous granites, potential new calibrations exist for the assemblages bearing garnet, biotite, plagioclase, muscovite, and quartz. Other thermometers, based on oxygen abundance, and including Fe-Ti oxides, pyroxene, fayalitic olivine, quartz, sphene, and/or biotite, some of which have been recently revised, can provide additional information on temperature and oxygen fugacity. Oxygen fugacity can range over several orders of magnitude in different magmatic systems and can have profound influence on the mineralogy and mineral compositions in granitic magmas. It also forms the foundation of the popular magnetite- versus ilmenite-series granite classification. Copyright ?? Mineralogical Society of America.
Peebles, E D; Zhai, W; Gerard, P D
2012-07-01
The current study was conducted to compare and contrast the uses of 2 devices (temperature transponder or infrared thermometer) and their locations (inner air cell membrane or outer eggshell surface) in Ross × Ross 708 broiler hatching eggs. The air cells of 14 embryonated and 10 nonembryonated eggs were implanted with temperature transponders on d 13.5 of incubation. Likewise, for these same eggs, eggshell surface temperature was detected with the use of transponders and an infrared thermometer. Temperatures were recorded every 12 h between 14.5 and 18 d of incubation, and graphs and corresponding regression values were used to track the temperatures over these time periods. The temperature readings using all methods in embryonated and nonembryonated eggs were positively correlated. In nonembryonated eggs, temperatures in the air cell and on the eggshell surface using transponders were higher than those on the eggshell surface using an infrared thermometer. Mean air cell temperature readings of embryonated eggs using transponders were higher than those of the eggshell, as determined with the use of transponders or an infrared thermometer. Furthermore, the differences in air cell temperature using transponders and eggshell temperature using an infrared thermometer in embryonated eggs increased with embryonic age. These readings confirmed increased embryo heat production during the incubational period examined. It was further concluded that when compared with actual embryo body temperatures determined in previous studies, the use of transponders in the air cells of broiler hatching eggs detected a higher and closer temperature than eggshell surface temperature. It is suggested that the air cell transponders in embryonated eggs circumvented the confounding effects of the thermal barrier properties of the eggshell and the flow of air across its surface.
Development of a sapphire fiber thermometer using two wavelength bands
NASA Astrophysics Data System (ADS)
Ye, Linhua; Shen, Yonghang
1996-09-01
This paper reports the development of a sapphire ((alpha) - Al2O3) single crystal optical fiber thermometer using two wavelength bands. A thin film of precious metal or ceramic deposited onto one end of the sapphire fiber forms a mini-radiation cavity. The other end of the sapphire fiber is coupled to a low-loss silica fiber. Radiation from the small cavity is transmitted along the silica fiber into a photodetection system which consists of a lens, beam splitter, two interference filters (820 nm and 940 nm center wavelength, 30 nm bandwidth) and two silicon photocells. The temperature measurement is based on the detection of radiation from the small cavity. The sapphire fiber (0.25 - 1.0 mm diameter, 100 - 450 mm length) was grown by the laser heated pedestal growth (LHPG) methods. Transmission loss in the sapphire fiber was experimentally measured. Theoretical analysis shows the apparent emittance of the small cavity with a length to diameter (L/D) ratio greater than eight is a constant value near to one, so the small cavity can be considered as a small black-body cavity. Using the developed sapphire fiber temperature sensor, we have built a sapphire fiber thermometer based on a 8098 single-chip microcomputer system. It was calibrated at some known stable temperature point and uses the fundamental radiation law to extrapolate to other temperatures. By taking the ratio of the optical power at two wavelengths, errors due to changes in the system, such as emissivity and transmission losses, can be canceled out. The thermometer has an operating temperature range of 800 to 1900 degrees Celsius, and an accuracy of 0.2% at 1000 degrees Celsius. There are a number of applications of the thermometer both in science and industry.
Clumped isotope composition of cold-water corals: A role for vital effects?
NASA Astrophysics Data System (ADS)
Spooner, Peter T.; Guo, Weifu; Robinson, Laura F.; Thiagarajan, Nivedita; Hendry, Katharine R.; Rosenheim, Brad E.; Leng, Melanie J.
2016-04-01
The carbonate clumped isotope thermometer is a promising tool for determining past ocean temperatures. It is based on the temperature dependence of rare isotopes 'clumping' into the same carbonate ion group in the carbonate mineral lattice. The extent of this clumping effect is independent of the isotope composition of the water from which carbonate precipitates, providing unique advantages over many other paleotemperature proxies. Existing calibrations of this thermometer in cold-water and warm-water corals suggest clumped isotope 'vital effects' are negligible in cold-water corals but may be significant in warm-water corals. Here, we test the calibration of the carbonate clumped isotope thermometer in cold-water corals with a recently collected and well characterised sample set spanning a range of coral genera (Balanophyllia, Caryophyllia, Dasmosmilia, Desmophyllum, Enallopsammia and Javania). The clumped isotope compositions (Δ47) of these corals exhibit systematic dependences on their growth temperatures, confirming the basis of the carbonate clumped isotope thermometer. However, some cold-water coral genera show Δ47 values that are higher than the expected equilibrium values by up to 0.05‰ (equivalent to underestimating temperature by ∼9 °C) similar to previous findings for some warm-water corals. This finding suggests that the vital effects affecting corals Δ47 are common to both warm- and cold-water corals. By comparison with models of the coral calcification process we suggest that the clumped isotope offsets in these genera are related to the kinetic isotope effects associated with CO2 hydration/hydroxylation reactions in the corals' calcifying fluid. Our findings complicate the use of the carbonate clumped isotope thermometer in corals, but suggest that species- or genus-specific calibrations could be useful for the future application of this paleotemperature proxy.
Edelu, Benedict O; Ojinnaka, Ngozi C; Ikefuna, Anthony N
2011-01-22
Monitoring of body temperature is an important clinical procedure in the care of sick children, especially the under-5 children, as many disease conditions present with fever. The oral mercury-in-glass thermometer which has relatively good accuracy cannot be used in children less than 5 years because it requires their cooperation. This study was aimed at using the infrared tympanic thermometer (IRTT) in oral mode to measure temperature in febrile and afebrile children less than 5 years. Rectal and tympanic temperatures were measured consecutively in 400 febrile and 400 afebrile under-5 children matched for age, using the mercury-in-glass thermometer and the IRTT in oral mode respectively. In the febrile children, the mean tympanic temperature was 38.6 ± 0.9°C, while the mean rectal temperature was 39.0 ± 0.8°C. In the afebrile group, the mean tympanic temperature was 37.0 ± 0.4°C, while the mean rectal temperature was 37.4 ± 0.3°C. The mean difference between rectal and tympanic temperatures in both groups was statistically significant. There was good correlation between the two temperatures. The tympanic thermometer used in the oral mode had a sensitivity of 87.3% and a specificity of 96.5%. The IRTT (oral mode) may not be reliable in estimating 'core' body temperature in children under the age of five years, but with a fairly good sensitivity and specificity, as well as its other advantages such as short duration of measurement, convenience and safety, it is a useful instrument for screening children with fever in a busy setup.
Evaluation of Small-Sized Platinum Resistance Thermometers with ITS-90 Characteristics
NASA Astrophysics Data System (ADS)
Yamazawa, K.; Anso, K.; Widiatmo, J. V.; Tamba, J.; Arai, M.
2011-12-01
Many platinum resistance thermometers (PRTs) are applied for high precision temperature measurements in industry. Most of the applications use PRTs that follow the industrial standard of PRTs, IEC 60751. However, recently, some applications, such as measurements of the temperature distribution within equipments, require a more precise temperature scale at the 0.01 °C level. In this article the evaluation of remarkably small-sized PRTs that have temperature-resistance characteristics very close to that of standard PRTs of the International Temperature Scale of 1990 (ITS-90) is reported. Two types of the sensing element were tested, one is 1.2 mm in diameter and 10 mm long, the other is 0.8 mm and 8 mm. The resistance of the sensor is 100 Ω at the triple-point-of-water temperature. The resistance ratio at the Ga melting-point temperature of the sensing elements exceeds 1.11807. To verify the closeness of the temperature-resistance characteristics, comparison measurements up to 157 °C were employed. A pressure-controlled water heat-pipe furnace was used for the comparison measurement. Characteristics of 19 thermometers with these small-sized sensing elements were evaluated. The deviation from the temperature measured using a standard PRT used as a reference thermometer in the comparison was remarkably small, when we apply the same interpolating function for the ITS-90 sub-range to these small thermometers. Results including the stability of the PRTs and the uncertainty evaluation of the comparison measurements, and the comparison results showing the small deviation from the ITS-90 temperature-resistance characteristics are reported. The development of such a PRT might be a good solution for applications such as temperature measurements of small objects or temperature distribution measurements that need the ITS-90 temperature scale.
Shapiro, Michael A; Porticella, Norman; Jiang, L Crystal; Gravani, Robert B
2011-02-01
While most home cooks know about safe home food handling procedures, compliance is generally low and has not been much improved by campaigns. Foodborne disease is a common cause of illness, hospitalization and even death, and many of these illnesses are caused by unsafe home food practices. Using the theory of planned behavior as a model, survey data were analyzed. Perceived behavioral control was the strongest predictor of behavioral intentions for both hand washing and food thermometer use. Subjective norm was the next strongest predictor for thermometer use, while attitude towards the behavior was the next strongest predictor for hand washing. This is consistent with earlier focus group results for thermometer use and suggests some possible strategies for designing future home food safety messages. Copyright © 2010 Elsevier Ltd. All rights reserved.
Evaluation tests of platinum resistance thermometers for a cryogenic wind tunnel application
NASA Technical Reports Server (NTRS)
Germain, E. F.; Compton, E. C.
1984-01-01
Thirty-one commercially designed platinum resistance thermometers were evaluated for applicability to stagnation temperature measurements between -190 C and +65 C in the Langley Research Center's National Transonic Facility. Evaluation tests included X-ray shadowgraphs, calibrations before and after aging, and time constant measurements. Two wire-wound low thermal mass probes of a conventional design were chosen as most suitable for this cryogenic wind tunnel application.
Thermodynamics and historical relevance of a jetting thermometer made of Chinese zisha ceramic
NASA Astrophysics Data System (ADS)
Lee, Vincent; Attinger, Daniel
2016-07-01
Following a recent trend of scientific studies on artwork, we study here the thermodynamics of a thermometer made of zisha ceramic, related to the Chinese tea culture. The thermometer represents a boy who “urinates” shortly after hot water is poured onto his head. Long jetting distance is said to indicate that the water temperature is hot enough to brew tea. Here, a thermodynamic model describes the jetting phenomenon of that pee-pee boy. The study demonstrates how thermal expansion of an interior air pocket causes jetting. A thermodynamic potential is shown to define maximum jetting velocity. Seven optimization criteria to maximize jetting distance are provided, including two dimensionless numbers. Predicted jetting distances, jet durations, and temperatures agree very well with infrared and optical measurements. Specifically, the study confirms that jetting distances are sensitive enough to measure water temperature in the context of tea brewing. Optimization results show that longer jets are produced by large individuals, with low body mass index, with a boyhood of medium size inclined at an angle π/4. The study ends by considering the possibility that ceramic jetting artifacts like the pee-pee boy might have been the first thermometers known to mankind, before Galileo Galilei’s thermoscope.
NASA Astrophysics Data System (ADS)
Liedberg, Hans; Abdelaziz, Yasser; Tesfaye, Fitsum; Egadwa, Wilson; Norranim, Uthai; Rwashana, Simon; Kagoma, Alphonce; Ziagi, Adam; Kwong, Christian Ng Ha; Madeleine, Gilbert
2017-01-01
A Regional Metrology Organization (RMO) supplementary comparison of platinum resistance thermometer and digital thermometer (AFRIMETS.T-S1) was carried out by the National Metrology Institute of South Africa (NMISA), National Institute for Standards Egypt (NIS), National Metrology Institute of Ethiopia (NMIE), Kenya Bureau of Standards (KEBS), National Institute of Metrology Thailand (NIMT), Uganda National Bureau of Standards (UNBS), Tanzania Bureau of Standards (TBS), Mauritius Standards Bureau (MSB) and Seychelles Bureau of Standards (SBS) between March 2008 and October 2010. The temperature range of the inter comparison is -50 °C to 450 °C. The results of this comparison are reported here, along with descriptions of the Artefacts and devices used during measurement. This report also presents the uncertainty budget. The results are analysed and normalized error (En) values are reported. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Thermodynamics and historical relevance of a jetting thermometer made of Chinese zisha ceramic
Lee, Vincent; Attinger, Daniel
2016-01-01
Following a recent trend of scientific studies on artwork, we study here the thermodynamics of a thermometer made of zisha ceramic, related to the Chinese tea culture. The thermometer represents a boy who “urinates” shortly after hot water is poured onto his head. Long jetting distance is said to indicate that the water temperature is hot enough to brew tea. Here, a thermodynamic model describes the jetting phenomenon of that pee-pee boy. The study demonstrates how thermal expansion of an interior air pocket causes jetting. A thermodynamic potential is shown to define maximum jetting velocity. Seven optimization criteria to maximize jetting distance are provided, including two dimensionless numbers. Predicted jetting distances, jet durations, and temperatures agree very well with infrared and optical measurements. Specifically, the study confirms that jetting distances are sensitive enough to measure water temperature in the context of tea brewing. Optimization results show that longer jets are produced by large individuals, with low body mass index, with a boyhood of medium size inclined at an angle π/4. The study ends by considering the possibility that ceramic jetting artifacts like the pee-pee boy might have been the first thermometers known to mankind, before Galileo Galilei’s thermoscope. PMID:27431925
Blackbody for metrological control of ear thermometers
NASA Astrophysics Data System (ADS)
Cárdenas-García, D.; Méndez-Lango, E.
2013-09-01
Body temperature is an important parameter in medical practice, and most of health diagnoses are made based upon measured temperature values. Non-contact measurements are attractive to both patients and physicians, and ear thermometers (ET) are part of the set of infrared thermometers for medical applications. ETs sense the tympanic membrane temperature which best represents body temperature. They take advantage of the natural high effective emissivity cavity that is formed as radiation source. To calibrate or to check the performance of ETs, we designed a high-emissivity spherical cavity as a blackbody source which can be placed in a dry block oven. Although the blackbody cavity can have any shape, we decided to build it spherical because its effective emissivity can be easily calculated in a closed form. The cavity is made of Aluminum to take advantage of its high thermal conductivity while its inner side is covered with a black paint to increase the cavity effective emissivity. Based on paint emissivity measurements and the geometrical shape, we calculated that the cavity has an effective emissivity higher than 0.999. Blackbody temperature is measured with a calibrated contact thermometer placed inside the bottom wall of the cavity. We present the design of the cavity, the experimental setup, and results of three commercial ETs compared with this cavity.
Andreev current for low temperature thermometry
NASA Astrophysics Data System (ADS)
Faivre, T.; Golubev, D. S.; Pekola, J. P.
2015-05-01
We demonstrate experimentally that disorder enhanced Andreev current in a tunnel junction between a normal metal and a superconductor provides a method to measure electronic temperature, specifically at temperatures below 200 mK when aluminum is used. This Andreev thermometer has some advantages over conventional quasiparticle thermometers: For instance, it does not conduct heat and its reading does not saturate until at lower temperatures. Another merit is that the responsivity is constant over a wide temperature range.
The Air Force Weapons Laboratory Skid Resistance Research Program, 1969- 1974
1975-05-01
M(d) The slope measuring device consists of a rectangular section of aluminum (10-ft lonq, 5/8-in thick, and 2-1/2-in high) with machinists levels...pipe lines, meters, weight buckets, spray bars, and other containers of flow lines. i. Thermometric Equipment, An armored thermometer with a range from...shall be further equipped with an approved dial-scale mercury-actuated thermometer, an electric pyrometer, or other approved thermometric instruments
27 CFR 30.22 - Hydrometers and thermometers.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 105 to 125 0.2° N 125 to 145 0.2° P 145 to 165 0.2° Q 165 to 185 0.2° R 185 to 206 0.2° Thermometers are designated by type according to range of degrees Fahrenheit and are provided in ranges and subdivisions of degrees as follows: Type Range Subdivision Pencil type 10° to 100° 1° V-back 10° to 100° 1...
May, T.; Cornish, K.; Rinehart, N. J.
2015-01-01
Children with Autism Spectrum Disorder (ASD) experience high anxiety which often prompts clinical referral and requires intervention. This study aimed to compare parent and child reports on the Spence Children's Anxiety Scale (SCAS) and a child-reported “worry thermometer” in 88 children aged 8–13 years, 44 with ASD and 44 age, gender, and perceptual IQ matched typically developing children. There were no gender differences in child report on the SCAS and worry thermometers. Results indicated generally good correlations between parent and child self-reported SCAS symptoms for typically developing children but poor agreement in parent-child ASD dyads. The worry thermometer child-report did not reflect child or parent reports on the SCAS. Findings suggest 8–13-year-old children with ASD may have difficulties accurately reporting their anxiety levels. The clinical implications were discussed. PMID:25922765
Reliability of infrared thermometric measurements of skin temperature in the hand.
Packham, Tara L; Fok, Diana; Frederiksen, Karen; Thabane, Lehana; Buckley, Norman
2012-01-01
Clinical measurement study. Skin temperature asymmetries (STAs) are used in the diagnosis of complex regional pain syndrome (CRPS), but little evidence exists for reliability of the equipment and methods. This study examined the reliability of an inexpensive infrared (IR) thermometer and measurement points in the hand for the study of STA. ST was measured three times at five points on both hands with an IR thermometer by two raters in 20 volunteers (12 normals and 8 CRPS). ST measurement results using IR thermometers support inter-rater reliability: intraclass correlation coefficient (ICC) estimate for single measures 0.80; all ST measurement points were also highly reliable (ICC single measures, 0.83-0.91). The equipment demonstrated excellent reliability, with little difference in the reliability of the five measurement sites. These preliminary findings support their use in future CRPS research. Not applicable. Copyright © 2012 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.
A Molecular Fluorescent Probe for Targeted Visualization of Temperature at the Endoplasmic Reticulum
Arai, Satoshi; Lee, Sung-Chan; Zhai, Duanting; Suzuki, Madoka; Chang, Young Tae
2014-01-01
The dynamics of cellular heat production and propagation remains elusive at a subcellular level. Here we report the first small molecule fluorescent thermometer selectively targeting the endoplasmic reticulum (ER thermo yellow), with the highest sensitivity reported so far (3.9%/°C). Unlike nanoparticle thermometers, ER thermo yellow stains the target organelle evenly without the commonly encountered problem of aggregation, and successfully demonstrates the ability to monitor intracellular temperature gradients generated by external heat sources in various cell types. We further confirm the ability of ER thermo yellow to monitor heat production by intracellular Ca2+ changes in HeLa cells. Our thermometer anchored at nearly-zero distance from the ER, i.e. the heat source, allowed the detection of the heat as it readily dissipated, and revealed the dynamics of heat production in real time at a subcellular level. PMID:25330751
Primary thermometry with nanoscale tunnel junctions
NASA Astrophysics Data System (ADS)
Hirvi, K. P.; Kauppinen, J. P.; Paalanen, M. A.; Pekola, J. P.
1995-10-01
We have found current-voltage (I-V) and conductance (dI/dV) characteristics of arrays of nanoscale tunnel junctions between normal metal electrodes to exhibit suitable features for primary thermometry. The current through a uniform array depends on the ratio of the thermal energy kBT and the electrostatic charging energy E c of the islands between the junctions and is completely blocked by Coulomb repulsion at T = 0 and at small voltages eV/2 ≤ Ec. In the opposite limit, kBT ≫ Ec, the width of the conductance minimum scales linearly and universally with T and N, the number of tunnel junctions, and qualifies as a primary thermometer. The zero bias drop in the conductance is proportional to T-1 and can be used as a secondary thermometer. We will show with Monte Carlo simulations how background charge and nonuniformities of the array will affect the thermometer.
Maxwell, Branden M; Brunell, Marla K; Olsen, Cara H; Bentzel, David E
2016-01-01
Body temperature is a common physiologic parameter measured in both clinical and research settings, with rectal thermometry being implied as the ‘gold standard.’ However, rectal thermometry usually requires physical or chemical restraint, potentially causing falsely elevated readings due to animal stress. A less stressful method may eliminate this confounding variable. The current study compared 2 types of digital rectal thermometers—a calibrated digital thermometer and a common digital thermometer—with an implantable subcutaneous transponder microchip. Microchips were implanted subcutaneously between the shoulder blades of 16 ferrets (8 male, 8 female), and temperatures were measured twice from the microchip reader and once from each of the rectal thermometers. Results demonstrated the microchip temperature readings had very good to good correlation and agreement to those from both of the rectal thermometers. This study indicates that implantable temperature-sensing microchips are a reliable alternative to rectal thermometry for monitoring body temperature in ferrets. PMID:27177569
Comparison of Cryogenic Temperature Sensor Installation Inside or Outside the Piping
NASA Astrophysics Data System (ADS)
Müller, R.; Süßer, M.
2010-04-01
Cryogenic thermometers for large cryogenic facilities, like superconducting particle accelerator or fusion devices, must be able to withstand very severe conditions over the lifetime of the facility. In addition to the proper selection of the sensor, the choice of the appropriate installation method plays an important role for satisfying operation. Several characteristics must be taken into account, for instance: large numbers of sensors, different claims of accuracy, qualified preparation methods and at least qualified attachment of the sensor holder on the piping. One remedy to get satisfying results is the development of simple thermometer mounting fixtures, because thermometer mounting often may be realized by personnel with limited experience. This contribution presents two different methods for sensor installations, namely inside or outside installation on the piping. These have been the standard applications in the superconducting coil test facility TOSKA for many years. The characteristics of each of these methods will be discussed and compared.
Reliability of a novel thermal imaging system for temperature assessment of healthy feet.
Petrova, N L; Whittam, A; MacDonald, A; Ainarkar, S; Donaldson, A N; Bevans, J; Allen, J; Plassmann, P; Kluwe, B; Ring, F; Rogers, L; Simpson, R; Machin, G; Edmonds, M E
2018-01-01
Thermal imaging is a useful modality for identifying preulcerative lesions ("hot spots") in diabetic foot patients. Despite its recognised potential, at present, there is no readily available instrument for routine podiatric assessment of patients at risk. To address this need, a novel thermal imaging system was recently developed. This paper reports the reliability of this device for temperature assessment of healthy feet. Plantar skin foot temperatures were measured with the novel thermal imaging device (Diabetic Foot Ulcer Prevention System (DFUPS), constructed by Photometrix Imaging Ltd) and also with a hand-held infrared spot thermometer (Thermofocus® 01500A3, Tecnimed, Italy) after 20 min of barefoot resting with legs supported and extended in 105 subjects (52 males and 53 females; age range 18 to 69 years) as part of a multicentre clinical trial. The temperature differences between the right and left foot at five regions of interest (ROIs), including 1st and 4th toes, 1st, 3rd and 5th metatarsal heads were calculated. The intra-instrument agreement (three repeated measures) and the inter-instrument agreement (hand-held thermometer and thermal imaging device) were quantified using intra-class correlation coefficients (ICCs) and the 95% confidence intervals (CI). Both devices showed almost perfect agreement in replication by instrument. The intra-instrument ICCs for the thermal imaging device at all five ROIs ranged from 0.95 to 0.97 and the intra-instrument ICCs for the hand-held-thermometer ranged from 0.94 to 0.97. There was substantial to perfect inter-instrument agreement between the hand-held thermometer and the thermal imaging device and the ICCs at all five ROIs ranged between 0.94 and 0.97. This study reports the performance of a novel thermal imaging device in the assessment of foot temperatures in healthy volunteers in comparison with a hand-held infrared thermometer. The newly developed thermal imaging device showed very good agreement in repeated temperature assessments at defined ROIs as well as substantial to perfect agreement in temperature assessment with the hand-held infrared thermometer. In addition to the reported non-inferior performance in temperature assessment, the thermal imaging device holds the potential to provide an instantaneous thermal image of all sites of the feet (plantar, dorsal, lateral and medial views). Diabetic Foot Ulcer Prevention System NCT02317835, registered December 10, 2014.
IR fiber temperature sensing system
NASA Technical Reports Server (NTRS)
Tran, D. C.; Levin, K. H.; Mossadegh, R.; Koontz, Steve
1988-01-01
Infrared fiber optic pyrometry has become a practical reality using improved strength fluoride glass fibers. The addition of a plastic coating and rugged cabling allows the fibers to be used in the field. A detailed theoretical model of the infrared fiber optic pyrometer (non-contact or radiative thermometer) has been derived and compared with data produced by a prototype fluoride glass fiber radiative thermometer. Excellent agreement was obtained between theory and experiment over a temperature range of 30 to 700 C.
NASA Technical Reports Server (NTRS)
Cho, Hyung J.; Sukhatme, Kalyani G.; Mahoney, John C.; Penanen, Konstantin Penanen; Vargas, Rudolph, Jr.
2010-01-01
A method allows combining the functions of a heater and a thermometer in a single device, a thermistor, with minimal temperature read errors. Because thermistors typically have a much smaller thermal mass than the objects they monitor, the thermal time to equilibrate the thermometer to the temperature of the object is typically much shorter than the thermal time of the object to change its temperature in response to an external perturbation.
Final report on SIM.T-S5: comparison of the calibration of 100 Ω platinum resistance thermometers
NASA Astrophysics Data System (ADS)
del Campo, D.; García, S.; Velasquez, A.; Medrano, J. A.; Solano, A.; Torres, H. E.
2015-01-01
An International Comparison on industrial Platinum Resistance Thermometers (PRTs) among the National Metrology Institutes (NMIs) of Spain, Panama, Honduras, El Salvador, Costa Rica and Nicaragua began in 2013 and was successfully completed in 2014. Two PRTs were circulated (hand carried) and compared in the range from -38.8 °C up to 250 °C. The Centro Español de Metrología (Spanish NMI), CEM, acted as the pilot laboratory providing the reference value of the comparison. The thermometers have shown an acceptable behavior throughout the comparison, therefore the results can be considered valid for comparing the measurement capabilities of the participant laboratories. The equivalence between the participant laboratories in the calibration of platinum resistance thermometers by comparison in the range from -38,8 °C up to 250 °C has been demonstrated in almost all cases. This report presents the results of this comparison and provides detailed information of the measurements performed by the participating laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Ratiometric near infrared luminescent thermometer based on lanthanide metal-organic frameworks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yue, Dan; Zhang, Jun; Zhao, Dian
2016-09-15
A near infrared luminescent MOFs thermometer (Nd{sub 0.676}Yb{sub 0.324}BTC) was prepared via a simple solvothermal method using Ln{sup 3+} (Ln=Nd, Yb) ions and 1, 3, 5-benznenetricarboxylic acid (H{sub 3}BTC), and characterized by PXRD, TGA, ICP, and photoluminescence (PL) spectrum. These results indicate that the Nd{sub 0.676}Yb{sub 0.324}BTC displays high relative sensitivity and excellent repeatability in the physiological temperature range (288–323 K), and the maximum relative sensitivity is determined to be 1.187% K{sup −1} at 323 K. These NIR luminescent MOFs may have potential applications in physiological temperature sensing. - Graphical abstract: A near infrared luminescent MOFs thermometer (Nd{sub 0.054}Yb{sub 0.946}BTCmore » ) displays high relative sensitivity and excellent repeatability in the physiological temperature range (288–323 K). Display Omitted - Highlights: • A ratiometric near infrared luminescent MOFs thermometer (Nd{sub 0.676}Yb{sub 0.324}BTC) was prepared via a simple solvothermal method. • The maximum relative sensitivity of Nd{sub 0.676}Yb{sub 0.324}BTC is determined to be 1.187% K{sup −1} at 323 K. • Nd{sub 0.676}Yb{sub 0.324}BTC showed excellent repeatability in the physiological temperature range (288–323 K).« less
Characteristics of a liquid-helium-free calibration apparatus for cryogenic thermometers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shimazaki, T.
2013-09-11
Closed-cycle Joule-Thomson (JT) cryocoolers have been developed at National Metrology Institute of Japan (NMIJ)/National Institute of Advanced Industrial Science and Technology (AIST) with the aim of realizing a liquid-helium-free calibration apparatus for cryogenic thermometers between 0.65 K and 25 K. The latest JT cryocooler at NMIJ/AIST consists of a {sup 3}He JT cooling circuit and a pulse tube mechanical refrigerator. The characteristics of the apparatus including a residual gas analysis of the JT cooling circuit are presented in this paper. Currently the initial cool-down is performed using a heat-exchange gas. It normally takes about 30 h to reduce the temperaturemore » from room temperature to 5 K at the thermometer comparison block of the apparatus. The correct timing of the removal of the heatexchange gas is important for the efficient operation of the apparatus. Incomplete removal of the heat-exchange gas induces excess heat load on the apparatus and thermal disturbances. Some examples of abrupt temperature bursts are discussed in this paper. Mechanical refrigerators generate cyclic mechanical vibrations, and precision resistance thermometers are usually very sensitive to a mechanical vibration. The measured vibration level of the developed apparatus is reported. The damage to the apparatus due to the magnitude 9.0 earthquake on March 11, 2011, and possible countermeasures in the case of future earthquakes are also discussed.« less
Oztas, Zafer; Barut Selver, Ozlem; Akkin, Cezmi; Canturk, Ecem; Afrashi, Filiz
2016-05-01
In our study, we aimed to investigate the correlation of handheld infrared skin thermometer and videothermography device for the measurement of corneal temperature. Forty healthy individuals (80 eyes) were enrolled to the study. Participants underwent a detailed ophthalmologic examination and medical history review for excluding any ocular and systemic diseases. The measurements of the central corneal temperature were performed in a room having constant temperature, humidity, and brightness levels. To avoid any variability, all the temperature measurements were performed in the same examination room by a single examiner. The temperature was measured with a handheld infrared skin thermometer (MEDISANA, FTN) from the corneal surface. The same instrument was also used to measure the subjects' body temperature. Moreover, the subjects underwent the corneal temperature measurement by a noncontact videothermography device (Optris PI 450; Optris GmbH). The male to female ratio was 19:21 among the subjects. The mean age was 25.1±4.7 years. The mean body temperature was 36.93±0.33°C. The mean corneal temperatures measured by the handheld infrared skin thermometer and the ocular videothermography device were 36.94±0.28°C and 35.61±0.61°C, respectively (P<0.01). The mean temperature difference was 1.34±0.57°C, with a 95% confidence interval. There was a moderate correlation between the corneal temperatures measured by the 2 devices in the right, the left eyes, and both eyes, respectively (P=0.450, 0.539, 0.490). Handheld infrared skin thermometers can be used for the evaluation of the corneal temperature. These devices may provide a simple, practical, and cheaper way to detect the corneal temperature, and the widely performed corneal temperature measurements may afford us to understand the temperature variability in numerous ocular conditions in a better way.
NASA Astrophysics Data System (ADS)
Dygert, Nick; Liang, Yan
2015-06-01
Mantle peridotites from ophiolites are commonly interpreted as having mid-ocean ridge (MOR) or supra-subduction zone (SSZ) affinity. Recently, an REE-in-two-pyroxene thermometer was developed (Liang et al., 2013) that has higher closure temperatures (designated as TREE) than major element based two-pyroxene thermometers for mafic and ultramafic rocks that experienced cooling. The REE-in-two-pyroxene thermometer has the potential to extract meaningful cooling rates from ophiolitic peridotites and thus shed new light on the thermal history of the different tectonic regimes. We calculated TREE for available literature data from abyssal peridotites, subcontinental (SC) peridotites, and ophiolites around the world (Alps, Coast Range, Corsica, New Caledonia, Oman, Othris, Puerto Rico, Russia, and Turkey), and augmented the data with new measurements for peridotites from the Trinity and Josephine ophiolites and the Mariana trench. TREE are compared to major element based thermometers, including the two-pyroxene thermometer of Brey and Köhler (1990) (TBKN). Samples with SC affinity have TREE and TBKN in good agreement. Samples with MOR and SSZ affinity have near-solidus TREE but TBKN hundreds of degrees lower. Closure temperatures for REE and Fe-Mg in pyroxenes were calculated to compare cooling rates among abyssal peridotites, MOR ophiolites, and SSZ ophiolites. Abyssal peridotites appear to cool more rapidly than peridotites from most ophiolites. On average, SSZ ophiolites have lower closure temperatures than abyssal peridotites and many ophiolites with MOR affinity. We propose that these lower temperatures can be attributed to the residence time in the cooling oceanic lithosphere prior to obduction. MOR ophiolites define a continuum spanning cooling rates from SSZ ophiolites to abyssal peridotites. Consistent high closure temperatures for abyssal peridotites and the Oman and Corsica ophiolites suggests hydrothermal circulation and/or rapid cooling events (e.g., normal faulting, unroofing) control the late thermal histories of peridotites from transform faults and slow and fast spreading centers with or without a crustal section.
Dual-mode self-validating resistance/Johnson noise thermometer system
Shepard, Robert L.; Blalock, Theron V.; Roberts, Michael J.
1993-01-01
A dual-mode Johnson noise and DC resistance thermometer capable of use in control systems where prompt indications of temperature changes and long term accuracy are needed. A resistance-inductance-capacitance (RLC) tuned circuit produces a continuous voltage signal for Johnson noise temperature measurement. The RLC circuit provides a mean-squared noise voltage that depends only on the capacitance used and the temperature of the sensor. The sensor has four leads for simultaneous coupling to a noise signal processor and to a DC resistance signal processor.
High Frontier - The Journal for Space and Cyberspace Professionals. Volume 6, Number 3, May 2010.
2010-05-01
possible to use automated design flows, not just confined to a static system, but distributed and virtually through a web connection. This idea is...Imagine testing a thermometer using a blow dryer . Simple, but effective, except we have doz- ens of thermometers, some embedded deeply in a nearly...publications, four receiving best paper awards, and has been awarded 11 US patents. S&T. Yet we must adapt, or be left behind. Can we find a
Automated system for measuring temperature profiles inside ITS-90 fixed-point cells
NASA Astrophysics Data System (ADS)
Hiti, Miha; Bojkovski, Jovan; Batagelj, Valentin; Drnovsek, Janko
2005-11-01
The defining fixed points of the International Temperature Scale of 1990 (ITS-90) are temperature reference points for temperature calibration. The measured temperature inside the fixed-point cell depends on thermometer immersion, since measurements are made below the surface of the fixed-point material and the additional effect of the hydrostatic pressure has to be taken into account. Also, the heat flux along the thermometer stem can affect the measured temperature. The paper presents a system that enables accurate and reproducible immersion profile measurements for evaluation of measurement sensitivity and adequacy of thermometer immersion. It makes immersion profile measurements possible, where a great number of repetitions and long measurement periods are required, and reduces the workload on the user for performing such measurements. The system is flexible and portable and was developed for application to existing equipment in the laboratory. Results of immersion profile measurements in a triple point of water fixed-point cell are presented.
Argon Triple-Point Device for Calibration of SPRTs
NASA Astrophysics Data System (ADS)
Kołodziej, B.; Manuszkiewicz, H.; Szmyrka-Grzebyk, A.; Lipiński, L.; Kowal, A.; Steur, P. P. M.; Pavese, F.
2015-03-01
This paper presents an apparatus for the calibration of long-stem platinum resistance thermometers at the argon triple point , designed at the Institute of Low Temperature and Structural Research, Poland (INTiBS). A hermetically sealed cell filled at the Istituto Nazionale di Ricerca Metrologica, Italy with high purity gas (6N) is the main element of this apparatus. The cell is placed in a cryostat fully immersed in liquid nitrogen. A temperature-controlled shield ensures the quasi-adiabatic condition needed for proper realization of the phase transition. A system for correcting the temperature distribution along the thermometer well is also implemented. The cell cooling and argon solidification is carried out by filling the thermometer well with liquid nitrogen. A LabVIEW computer program written at INTiBS automatically controls the triple-point realization process. The duration of a melting plateau in the apparatus lasts for about 24 h. The melting width for between 20 % and 80 % was mK. The reproducibility of the plateau temperature is better than.
NASA Astrophysics Data System (ADS)
Bloembergen, P.; Bonnier, G.; Ronsin, H.
1990-01-01
Argon triple point calibration facilities have been compared among eight laboratories with one transfer system, employing local long-stem standard platinum resistance thermometers. The apparatus intercompared, included a sealed cell and its associated cryostat. As is evidenced by the results of long-term investigations, previously performed at the INM, cells of the type employed may show a triple-point temperature, which is stable within the reproducibility of the measurements (simeq0,1 mK) over a period of about 10 years. At each laboratory the mean difference between the Argon triple-point temperature of the transfer cell (t) and the local cell (i) has been determined, using a standard resistance thermometer previously calibrated at the fixed points, according to the IPTS-68; associated repeatabilities are typically of the order of 0,1 mK. The reproducibility attained by measuring the mean difference in different laboratories, using cells of the same type and origin (INM), amounts to 0,4 mK.
Fabrication and design of vanadium oxide microbolometer
NASA Astrophysics Data System (ADS)
Abdel-Rahman, M.; Al-Khalli, N.; Zia, M. F.; Alduraibi, M.; Ilahi, B.; Awad, E.; Debbar, N.
2017-02-01
Vanadium oxide (VxOy) multilayer sandwich structures previously studied by our group were found to yield a sensitive thermometer thin film material suitable for microbolometer applications. In this work, we aim to estimate the performance of a proposed air-bridge microbolometer configuration based on VxOy multilayer sandwich structure thermometer thin films. For this purpose, a microbolometer was fabricated on silicon (Si) substrate covered with a silicon nitride (Si3N4) insulating layer using VxOy thermometer thin film material. The fabricated microbolometer was patterned using electron-beam lithography and liftoff techniques and it was characterized in terms of its voltage repsonsivity (Rv), signal to noise ratio (SNR), noise equivalent power (NEP) and detectivity D*. A model was then developed by the aid of numerical optical/thermal simulations and experimentally measured parameters to estimate the performance of the microbolometer when fabricated in an air-bridge configuration. The estimated D* was found to be 1.55×107 cm.√Hz/ W.
High-Precision Temperature Control of a Crystal Growth Furnace at 1,500 C
NASA Technical Reports Server (NTRS)
Stenzel, Ch.; Hess, A.; Croell, A.; Breuer, D.; Sauermann, H.
2012-01-01
For crystal growth of semiconductor materials a short-term temperature stability of 0.1 C at 1500 C is one of the essential parameters to be addressed for achieving high-quality crystals. Hence, for temperature monitoring and control with high precision in a floating zone furnace two sets of thermo-sensors, type B thermocouples and optical fibre thermometers, have been implemented and successfully operated in the furnace for more than 2000 h. The optical fibre thermometers consist of an optical system made of sapphire (two fibres plus a prism in between for deflection) and transmit the infra-red radiation of the heater to the outside of the hot core of the furnace for pyrometric temperature measurement. A dedicated control algorithm has been set up which controlled the power settings to the individual heaters. Both sensor types showed no degradation after this period and yielded a short-term stability at 1200 C of 0.05 C (optical fibre thermometers), respectively 0.08 C (thermocouples).
NASA Astrophysics Data System (ADS)
Li, Zebin; Li, Xianglin; Li, Ting
2018-02-01
Tissue inflammation is often accompanied by fever and edema, which are common and troublesome problems that probably trigger disability, lymphangitis, cosmetic deformity and cellulitis. Here we developed a device, which can measure concentration and temperature variations of water in local human body by extended near infrared spectroscopy in 900 1000 nm wavelength range. An experiment of four steps incremental cycling exercise was designed to change tissue water concentration and temperature of subjects. Body temperature was also estimated by tympanic thermometer and surface thermometer as comparisons during the experiment. In the stage of recovery after exercise, the signal detected by custom device is similar to tympanic thermometer at the beginning, but it is closer to the temperature of surface later. In particular, this signal shows a better linearity, and a significant change when the exercise was suspended. This study demonstrated the potential of optical touch-sensing for inflammation severity monitoring by measuring water concentration and temperature variations in local lesions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ojanen, M.; Hahtela, O. M.; Heinonen, M.
MIKES is developing a measurement set-up for calibrating thermocouples in the temperature range 960 °C - 1500 °C. The calibration method is based on direct comparison of thermocouples and radiation thermometers. We have designed a graphite blackbody comparator cell, which is operated in a horizontal single-zone tube furnace. The cell includes two blackbody cavities for radiation temperature measurements. The cavities have openings on opposite sides of the cell, allowing simultaneous measurement with two radiation thermometers. The design of the comparator allows three thermocouples to be calibrated simultaneously. The thermocouples to be calibrated are inserted in thermometer wells around one ofmore » the measurement cavities. We characterize the blackbody comparator in terms of repeatability, temperature distribution and emissivity. Finally, we validate the uncertainty analysis by comparing calibration results obtained for type B and S thermocouples to the calibration results reported by Technical Research Institute of Sweden (SP), and MIKES. The agreement in the temperature range 1000 °C - 1500 °C is within 0.90 °C, the average deviation being 0.17 °C.« less
Clinical accuracy of non-contact infrared thermometer from umbilical region in children: A new side.
Apa, Hurşit; Gözmen, Salih; Keskin-Gözmen, Şükran; Aslan, Fatma; Bayram, Nuri; Devrim, İlker
2016-01-01
Measurement from axillary site with digital thermometer has been accepted as the most accurate method. But this method is time consuming. Tympanic and forehead measurements are often used but don't always seem to be more appropriate. Another site, umbilical region, could be an alternative site. This study aims to compare the measurements with axillary digital thermometer and non-contact infrared thermometers at sites from umbilicus and forehead to determine whether umbilical site could be used accurately in children. For each method, 2,048 measurements in total were performed. Using axillary method as gold standard, with a cut-off temperature of 38oC, the sensitivities and specificities, positive and negative predictive values of umbilical and forehead temperatures and area under the ROC curve were determined in non obese children. There was a significant positive correlation between axillary and umbilical temperatures with a correlation coefficient of 0.78. The average difference between the mean of both axillary and umbilical temperatures was -0.47 ± 0.65°C. The Bland-Altman plot showed good accuracy with only 2.5 % of the readings falling outside the 95% level of confidence. Umbilical measurements showed sensitivity of 71.7% and specificity of 95.8%. The area under the ROC curve was 0.93. The easy application may lead noncontact measurements from umbilicus site to be the preferable method for health care providers, but agreement limits mentioned in this study should be considered.
Sapphire Whispering Gallery Thermometer
NASA Astrophysics Data System (ADS)
Strouse, G. F.
2007-12-01
An innovative sapphire whispering gallery thermometer (SWGT) is being explored at the National Institute of Standards and Technology (NIST) as a potential replacement for a standard platinum resistance thermometer (SPRT) for industrial applications that require measurement uncertainties of ≤ 10 mK. The NIST SWGT uses a synthetic sapphire monocrystalline disk configured as a uniaxial, dielectric resonator with whispering gallery modes between 14 GHz and 20 GHz and with Q-factors as large as 90,000. The prototype SWGT stability at the ice melting point (0°C) is ≤ 1 mK with a frequency resolution equivalent to 0.05 mK. The prototype SWGT measurement uncertainty ( k= 1) is 10 mK from 0°C to 100°C for all five resonance modes studied. These results for the SWGT approach the capabilities of industrial resistance thermometers. The SWGT promises greatly increased resistance to mechanical shock relative to SPRTs, over the range from -196°C to 500°C while retaining the low uncertainties needed by secondary calibration laboratories. The temperature sensitivity of the SWGT depends upon a well-defined property (the refractive index at microwave frequencies) and the thermal expansion of a pure material. Therefore, it is expected that SWGTs can be calibrated over a wide temperature range using a reference function, along with deviations measured at a few fixed points. This article reports the prototype SWGT stability, resolution, repeatability, and the temperature dependence of five whispering gallery resonance frequencies in the range from 0°C to 100°C.
Kitamura, Kei-Ichiro; Zhu, Xin; Chen, Wenxi; Nemoto, Tetsu
2010-01-01
The conventional zero-heat-flow thermometer, which measures the deep body temperature from the skin surface, is widely used at present. However, this thermometer requires considerable electricity to power the electric heater that compensates for heat loss from the probe; thus, AC power is indispensable for its use. Therefore, this conventional thermometer is inconvenient for unconstrained monitoring. We have developed a new dual-heat-flux method that can measure the deep body temperature from the skin surface without a heater. Our method is convenient for unconstrained and long-term measurement because the instrument is driven by a battery and its design promotes energy conservation. Its probe consists of dual-heat-flow channels with different thermal resistances, and each heat-flow-channel has a pair of IC sensors attached on its top and bottom. The average deep body temperature measurements taken using both the dual-heat-flux and then the zero-heat-flow thermometers from the foreheads of 17 healthy subjects were 37.08 degrees C and 37.02 degrees C, respectively. In addition, the correlation coefficient between the values obtained by the 2 methods was 0.970 (p<0.001). These results show that our method can be used for monitoring the deep body temperature as accurately as the conventional method, and it overcomes the disadvantage of the necessity of AC power supply. (c) 2009 IPEM. Published by Elsevier Ltd. All rights reserved.
Jarvis, Melanie; Guy, Katelyn J; König, Kai
2013-06-01
To study the impact on newborn behavioural states and accuracy of three infrared thermometers compared with digital axillary thermometer measurements in very low birth weight infants. Single-centre prospective observational study. Preterm infants born <1500-g birth weight were eligible. Infants were observed for pre-measurement behaviour state using a five-point neonatal behaviour observation tool. One infrared temperature was taken from each of the devices, followed by an axillary measurement. Further behaviour-state observations were recorded following infrared and axillary measurements. One hundred measurements were collected from each infrared device among a cohort of 42 very low birth weight infants. Only one infrared device showed satisfactory agreement with bias -0.071 (95% limits of agreement -0.68 to 0.54). The other two devices demonstrated poor agreement: bias -1.34; 95% limits of agreement -2.62 to -0.5 and bias -0.56; 95% limits of agreement -1.38 to 0.25. Neonatal behavioural scores showed only minimal changes when infrared measurements were performed but increased significantly following axillary measurements. The difference between the two modalities was statistically significant with a mean increase of 1.44 points following axillary measurements (95% confidence interval 1.21 to 1.67, P < 0.001). Temperature measurements taken with infrared thermometers demonstrated less disruption to preterm infants' behavioural state, however accuracy of devices varied. © 2013 The Authors. Journal of Paediatrics and Child Health © 2013 Paediatrics and Child Health Division (Royal Australasian College of Physicians).
Genetically encoded ratiometric fluorescent thermometer with wide range and rapid response
Nakano, Masahiro; Arai, Yoshiyuki; Kotera, Ippei; Okabe, Kohki; Kamei, Yasuhiro; Nagai, Takeharu
2017-01-01
Temperature is a fundamental physical parameter that plays an important role in biological reactions and events. Although thermometers developed previously have been used to investigate several important phenomena, such as heterogeneous temperature distribution in a single living cell and heat generation in mitochondria, the development of a thermometer with a sensitivity over a wide temperature range and rapid response is still desired to quantify temperature change in not only homeotherms but also poikilotherms from the cellular level to in vivo. To overcome the weaknesses of the conventional thermometers, such as a limitation of applicable species and a low temporal resolution, owing to the narrow temperature range of sensitivity and the thermometry method, respectively, we developed a genetically encoded ratiometric fluorescent temperature indicator, gTEMP, by using two fluorescent proteins with different temperature sensitivities. Our thermometric method enabled a fast tracking of the temperature change with a time resolution of 50 ms. We used this method to observe the spatiotemporal temperature change between the cytoplasm and nucleus in cells, and quantified thermogenesis from the mitochondria matrix in a single living cell after stimulation with carbonyl cyanide 4-(trifluoromethoxy)phenylhydrazone, which was an uncoupler of oxidative phosphorylation. Moreover, exploiting the wide temperature range of sensitivity from 5°C to 50°C of gTEMP, we monitored the temperature in a living medaka embryo for 15 hours and showed the feasibility of in vivo thermometry in various living species. PMID:28212432
Sousa, Marlos G.; Carareto, Roberta; Pereira-Junior, Valdo A.; Aquino, Monally C.C.
2011-01-01
Although the rectal mucosa remains the traditional site for measuring body temperature in dogs, an increasing number of clinicians have been using auricular temperature to estimate core body temperature. In this study, 88 mature healthy dogs had body temperatures measured with auricular and rectal thermometers. The mean temperature and confidence intervals were similar for each method, but Bland-Altman plots showed high biases and limits of agreement unacceptable for clinical purposes. The results indicate that auricular and rectal temperatures should not be interpreted interchangeably. PMID:21731094
Sousa, Marlos G; Carareto, Roberta; Pereira-Junior, Valdo A; Aquino, Monally C C
2011-04-01
Although the rectal mucosa remains the traditional site for measuring body temperature in dogs, an increasing number of clinicians have been using auricular temperature to estimate core body temperature. In this study, 88 mature healthy dogs had body temperatures measured with auricular and rectal thermometers. The mean temperature and confidence intervals were similar for each method, but Bland-Altman plots showed high biases and limits of agreement unacceptable for clinical purposes. The results indicate that auricular and rectal temperatures should not be interpreted interchangeably.
Force protection in contingency operations: an evaluation of temperature monitoring in Sierra Leone.
Cole, Catherine; Turnbull, C; Eardley, W; Hunt, P
2016-06-01
The deployment of the UK-led Joint Inter-Agency Taskforce to Sierra Leone in September 2014 brought the era of contingency operations into focus. Daily health screening of such deployed personnel forms a key element of medical force protection. We have performed a service evaluation of an existing screening programme and detail the comparison of the two thermometers used in this role. Data from the existing screening programme were used to inform a sample size required to enable statistically and clinically significant differences to be detected between the two interchangeably used thermometer systems in use. A prospective service evaluation on these devices was then carried out over a 10-day period and the data analysed by parametric tools. 10 personnel had their temperature recorded by both devices at the same time by a single operator every day. For the screened population, a mean temperature of 36.55°C and SD of 0.32°C was revealed. Powered to 80% with a two-tailed α of 0.05, the evaluation of the two thermometers revealed no significant difference between recordings taken with either device (p=0.115). The low SD meant that a pyrexial patient (>37.5°C) would require a recording over 3 SD from the population mean. Evaluations of medical force protection will carry increasing consequence as the UK deploy on short notice operations to regions of considerable endemic threat. Presence of pyrexia is a key early indicator of illness affecting deployed personnel, and two different thermometer types are provided for this function. We have shown for the first time with statistical and clinical significance that the two thermometers used in contingency force protection are interchangeable. The narrow variance is reassuring and confirms that the chosen trigger (>37.5°C) would warrant further investigation in the pyrexial patient. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
NASA Astrophysics Data System (ADS)
Gaiser, Christof; Fellmuth, Bernd; Steur, Peter; Szmyrka-Grzebyk, Anna; Manuszkiewicz, Henryk; Lipinski, Leszek; Peruzzi, Andrea; Rusby, Richard; Head, David
2017-01-01
In the temperature range from 0.65 K to 24.5561 K, the ITS-90 is defined by specified vapour-pressure equations for 3He and 4He and interpolation equations for a constant-volume gas thermometer using 3He or 4He. The definitions are given in sections 3.1 and 3.2 of the ITS-90 text, and methods for realising the scale in this range are outlined in chapters 4 and 5 of the Guide to the Realization of the ITS-90 (formerly Supplementary Information for the ITS-90). Direct realisations of the ITS-90 by these methods require relatively sophisticated apparatus and time-consuming experiments, and consequently they are rarely carried out. The situation is acceptable in practice only because rhodium-iron resistance thermometers (RIRTs) are available that, once calibrated, are able to maintain their calibrations reliably for long periods of time. They are the practical thermometers on which realisations of the ITS-90 are most accurately maintained, disseminated and compared. The key comparison EURAMET.T-K1 is therefore a comparison of calibrated RIRTs. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Yang, Jie; Liu, Qingquan; Dai, Wei; Ding, Renhui
2016-08-01
Due to the solar radiation effect, current air temperature sensors inside a thermometer screen or radiation shield may produce measurement errors that are 0.8 °C or higher. To improve the observation accuracy, an aspirated temperature measurement platform is designed. A computational fluid dynamics (CFD) method is implemented to analyze and calculate the radiation error of the aspirated temperature measurement platform under various environmental conditions. Then, a radiation error correction equation is obtained by fitting the CFD results using a genetic algorithm (GA) method. In order to verify the performance of the temperature sensor, the aspirated temperature measurement platform, temperature sensors with a naturally ventilated radiation shield, and a thermometer screen are characterized in the same environment to conduct the intercomparison. The average radiation errors of the sensors in the naturally ventilated radiation shield and the thermometer screen are 0.44 °C and 0.25 °C, respectively. In contrast, the radiation error of the aspirated temperature measurement platform is as low as 0.05 °C. This aspirated temperature sensor allows the radiation error to be reduced by approximately 88.6% compared to the naturally ventilated radiation shield, and allows the error to be reduced by a percentage of approximately 80% compared to the thermometer screen. The mean absolute error and root mean square error between the correction equation and experimental results are 0.032 °C and 0.036 °C, respectively, which demonstrates the accuracy of the CFD and GA methods proposed in this research.
Calibration of ultra-low infrared power at NIST
NASA Astrophysics Data System (ADS)
Woods, Solomon I.; Carr, Stephen M.; Carter, Adriaan C.; Jung, Timothy M.; Datla, Raju U.
2010-07-01
The Low Background Infrared (LBIR) facility has developed and tested the components of a new detector for calibration of infrared greater than 1 pW, with 0.1 % uncertainty. Calibration of such low powers could be valuable for the quantitative study of weak astronomical sources in the infrared. The pW-ACR is an absolute cryogenic radiometer (ACR) employing a high resolution transition edge sensor (TES) thermometer, ultra-weak thermal link and miniaturized receiver to achieve a noise level of around 1 fW at a temperature of 2 K. The novel thermometer employs the superconducting transition of a tin (Sn) core and has demonstrated a temperature noise floor less than 3 nK/Hz1/2. Using an applied magnetic field from an integrated solenoid to suppress the Sn transition temperature, the operating temperature of the thermometer can be tuned to any temperature below 3.6 K. The conical receiver is coated on the inside with infrared-absorbing paint and has a demonstrated absorptivity of 99.94 % at 10.6 μm. The thermal link is made from a thin-walled polyimide tube and has exhibited very low thermal conductance near 2x10-7 W/K. In tests with a heater mounted on the receiver, the receiver/thermal-link assembly demonstrated a thermal time constant of about 15 s. Based on these experimental results, it is estimated that an ACR containing these components can achieve noise levels below 1 fW, and the design of a radiometer merging the new thermometer, receiver and thermal link will be discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Jie, E-mail: yangjie396768@163.com; School of Atmospheric Physics, Nanjing University of Information Science and Technology, Nanjing 210044; Liu, Qingquan
Due to the solar radiation effect, current air temperature sensors inside a thermometer screen or radiation shield may produce measurement errors that are 0.8 °C or higher. To improve the observation accuracy, an aspirated temperature measurement platform is designed. A computational fluid dynamics (CFD) method is implemented to analyze and calculate the radiation error of the aspirated temperature measurement platform under various environmental conditions. Then, a radiation error correction equation is obtained by fitting the CFD results using a genetic algorithm (GA) method. In order to verify the performance of the temperature sensor, the aspirated temperature measurement platform, temperature sensors withmore » a naturally ventilated radiation shield, and a thermometer screen are characterized in the same environment to conduct the intercomparison. The average radiation errors of the sensors in the naturally ventilated radiation shield and the thermometer screen are 0.44 °C and 0.25 °C, respectively. In contrast, the radiation error of the aspirated temperature measurement platform is as low as 0.05 °C. This aspirated temperature sensor allows the radiation error to be reduced by approximately 88.6% compared to the naturally ventilated radiation shield, and allows the error to be reduced by a percentage of approximately 80% compared to the thermometer screen. The mean absolute error and root mean square error between the correction equation and experimental results are 0.032 °C and 0.036 °C, respectively, which demonstrates the accuracy of the CFD and GA methods proposed in this research.« less
Kongpanichkul, A; Bunjongpak, S
2000-09-01
This study was carried out to assess the accuracy of three devices namely, liquid crystal forehead, digital electronic axillary and infrared tympanic thermometer, using a glass-mercury rectal thermometer as the control. The subjects were two hundred children aged 0-48 months. The mean rectal temperature was 38.0 +/- 0.91 degrees C; forehead, 37.83 +/- 0.94 degrees C; tympanic, 37.77 +/- 0.95 degrees C, and axillary, 37.71 +/- 0.86 degrees C. Compared to the rectal temperature, all values were significantly lower (p < 0.05). Forehead, tympanic and axillary temperature differed from rectal temperature by at least 0.5 degrees C in 33.33 per cent, 23.5 per cent and 31.5 per cent of subjects, and at least 1 degrees C in 22 per cent, 1 per cent and 6 per cent of subjects respectively. Accuracy in detection of fever was 79 per cent for forehead, 85.5 per cent for tympanic and 84 per cent for axillary thermometry. Sensitivity of the three devices was 67-83 per cent in detection of fever and 64-77 per cent in detection of high fever. Tympanic thermometry had the best performance while forehead thermometry had the poorest. After using revised diagnostic threshold temperature by ROC curves, sensitivity of each device improved but accuracy was nearly the same. It is concluded that the three devices are not suitable as a substitute for a glass-mercury rectal thermometer in assessment of fever in infants and young children.
Craike, Melinda J; Livingston, Patricia M; Warne, Charles
2011-01-01
This study assessed the relative screening performance of the Distress Impact Thermometer (DIT) and cutoff levels with the established clinical case threshold of the Hospital Anxiety and Depression Scale (HADS) among a sample of colorectal cancer (CRC) survivors. Fifty-nine CRC survivors completed the DIT, HADS, and provided demographic information at baseline, and 45 of these patients completed the same measures at follow-up, giving a total of 104 participant data. Receiver operating characteristic (ROC) analysis was performed to determine the accuracy of the DIT compared to the HADS, with a cutoff score ≥8 on each HADS subscale (depression and anxiety) and ≥15 on the HADS total scale used to identify patients with psychological distress. The sample comprised slightly more males (63%) than females, with an average age of 59 years (SD = 9.53) and ranging from 33 to 77 years. The optimum DT cutoff score of ≥5 yielded a sensitivity of 60% and specificity of 86.1%; the area under the curve was 0.771 (95% confidence interval [CI] [0.646, 0.896]). For the depression subscale, the DT performed better on specificity than sensitivity, however the opposite was true for the anxiety subscale. The addition of an impact thermometer did not enhance screening performance. The results of this study provide support for a DT score of ≥5 for detecting psychological distress among CRC survivors and do not support the addition of an impact thermometer. The use of the DT might underestimate depression but overestimate anxiety.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Huizhen; Zhao, Dian; Cui, Yuangjing, E-mail: cuiyj@zju.edu.cn
Temperature measurements and thermal mapping using luminescent MOF operating in the high-temperature range are of great interest in the micro-electronic diagnosis. In this paper, we report a thermostable Eu/Tb-mixed MOF Eu{sub 0.37}Tb{sub 0.63}-BTC-a exhibiting strong luminescence at elevated temperature, which can serve as a ratiometric luminescent thermometer for high-temperature range. The high-temperature operating range (313–473 K), high relative sensitivity and accurate temperature resolution, make such a Eu/Tb-mixed MOF useful for micro-electronic diagnosis. - Graphical abstract: A thermostable Eu/Tb-mixed MOF Eu{sub 0.37}Tb{sub 0.63}-BTC-a was developed as a ratiometric luminescent thermometers in the high-temperature range of 313–473 K. - Highlights: • Amore » thermostable Eu/Tb-codoped MOF exhibiting strong luminescent at elevated temperature is reported. • The high-temperature operating range of Eu{sub 0.37}Tb{sub 0.63}-BTC-a is 313–473 K. • The mechanism of Eu{sub 0.37}Tb{sub 0.63}-BTC-a used as thermometers are also discussed.« less
Compact and low-cost fiber optic thermometer
NASA Astrophysics Data System (ADS)
Sun, Mei H.
1997-06-01
Commercial fiberoptic thermometers have been available for a number of years. The early products were unreliable and high in price. However, the continuing effort in the development of new sensing techniques along with the breakthroughs made in many areas of optoelectronics in recent years have made the production of cost competitive and reliable systems feasible. A fluorescence decay time based system has been demonstrated to successfully meet both cost and performance requirements for various medical applications. A very critical element to the success of this low cost and compact fiberoptic thermometer is the fluorescent sensor material. The very high quantum efficiency, the operating wavelengths, and the temperature sensitivity helped significantly in simplifying the design requirements for the optics and the electronics. The one to eight channel unit contains one to eight modules of a simple optical assembly: an LED light source, a small lens, and a filter are housed in an injection molded plastic container. Both the electronics and the optics reside on a small printed circuit board of approximately 6 inches by 3 inches. This system can be packaged as a stand alone unit or embedded in original manufacturer equipment.
Probing the thermal Hall effect using miniature capacitive strontium titanate thermometry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tinsman, Colin; Li, Gang; Asaba, Tomoya
2016-06-27
The thermal Hall effect is the thermal analog of the electrical Hall effect. Rarely observed in normal metals, thermal Hall signals have been argued to be a key property for a number of strongly correlated materials, such as high temperature superconductors, correlated topological insulators, and quantum magnets. The observation of the thermal Hall effect requires precise measurement of temperature in intense magnetic fields. Particularly at low temperature, resistive thermometers have a strong dependence on field, which makes them unsuitable for this purpose. We have created capacitive thermometers which instead measure the dielectric constant of strontium titanate (SrTiO{sub 3}). SrTiO{sub 3}more » approaches a ferroelectric transition, causing its dielectric constant to increase by a few orders of magnitude at low temperature. As a result, these thermometers are very sensitive at low temperature while having very little dependence on the applied magnetic field, making them ideal for thermal Hall measurements. We demonstrate this method by making measurements of the thermal Hall effect in Bismuth in magnetic fields of up to 10 T.« less
Reliability of an infrared forehead skin thermometer for core temperature measurements.
Kistemaker, J A; Den Hartog, E A; Daanen, H A M
2006-01-01
The SensorTouch thermometer performs an infrared measurement of the skin temperature above the Superficial Temporal Artery (STA). This study evaluates the validity and the accuracy of the SensorTouch thermometer. Two experiments were performed in which the body temperature was measured with a rectal sensor, with an oesophageal sensor and with the SensorTouch. After entering a warm chamber the SensorTouch underestimated the core temperature during the first 10 minutes. After that, the SensorTouch was not significantly different from the core temperature, with an average difference of 0.5 degrees C (SD 0.5 degrees C) in the first study and 0.3 degrees C (SD 0.2 degrees C) in the second study. The largest differences between the SensorTouch and the core temperature existed 15 minutes after the start of the exercise. During this period the SensorTouch was significantly higher than the core temperature. The SensorTouch did not provide reliable values of the body temperature during periods of increasing body temperature, but the SensorTouch might work under stable conditions.
NASA Astrophysics Data System (ADS)
Palenčár, Rudolf; Sopkuliak, Peter; Palenčár, Jakub; Ďuriš, Stanislav; Suroviak, Emil; Halaj, Martin
2017-06-01
Evaluation of uncertainties of the temperature measurement by standard platinum resistance thermometer calibrated at the defining fixed points according to ITS-90 is a problem that can be solved in different ways. The paper presents a procedure based on the propagation of distributions using the Monte Carlo method. The procedure employs generation of pseudo-random numbers for the input variables of resistances at the defining fixed points, supposing the multivariate Gaussian distribution for input quantities. This allows taking into account the correlations among resistances at the defining fixed points. Assumption of Gaussian probability density function is acceptable, with respect to the several sources of uncertainties of resistances. In the case of uncorrelated resistances at the defining fixed points, the method is applicable to any probability density function. Validation of the law of propagation of uncertainty using the Monte Carlo method is presented on the example of specific data for 25 Ω standard platinum resistance thermometer in the temperature range from 0 to 660 °C. Using this example, we demonstrate suitability of the method by validation of its results.
Two Fiber Optical Fiber Thermometry
NASA Technical Reports Server (NTRS)
Jones, Mathew R.; Farmer, Jeffery T.; Breeding, Shawn P.
2000-01-01
An optical fiber thermometer consists of an optical fiber whose sensing tip is given a metallic coating. The sensing tip of the fiber is essentially an isothermal cavity, so the emission from this cavity will be approximately equal to the emission from a blackbody. Temperature readings are obtained by measuring the spectral radiative heat flux at the end of the fiber at two wavelengths. The ratio of these measurements and Planck's Law are used to infer the temperature at the sensing tip. Optical fiber thermometers have high accuracy, excellent long-term stability and are immune to electromagnetic interference. In addition, they can be operated for extended periods without requiring re-calibration. For these reasons. it is desirable to use optical fiber thermometers in environments such as the International Space Station. However, it has recently been shown that temperature readings are corrupted by emission from the fiber when extended portions of the probe are exposed to elevated temperatures. This paper will describe several ways in which the reading from a second fiber can be used to correct the corrupted temperature measurements. The accuracy and sensitivity to measurement uncertainty will be presented for each method.
Response time correlations for platinum resistance thermometers
NASA Technical Reports Server (NTRS)
Pandey, D. K.; Ash, R. L.; Dillon-Townes, L. A.
1985-01-01
The 'plunge method' recommended by ASTM has been used to determine the time constant of 100-ohm platinum resistance thermometers (PRT) considered for use in the National Transonic Facility. It is shown that the response time of ventilated PRT can be correlated with the reciprocal of the heat transfer coefficient in a given field. Universal correlations are established for the 100- and 1000-ohm PRT with uncertainties of 20 and 30 percent, respectively. The correlations are found to be consistent with the uncertainty involved in heat transfer correlations available in the literature and are recommended for use in flowing liquids and gases.
Nanoscale Microelectronic Circuit Development
2011-06-17
structure to obtain a one-hot-encoded output instead of a thermometer code …………………………………………………………………………44 Figure 37. A folded ...thermometer code Figure 37. A folded PLINCO cell. The output of the PLINCO is 8-wide, but only the left half or right half is passed on. A carry...noise figure requirements are not stringent since the GPS signal is spread spectrum coded , providing over 40 dB of processing gain and easing the
Isotope and chemical age of the Greater Caucasus basement metamorphic rocks
NASA Astrophysics Data System (ADS)
Konilov, A. N.; Somin, M. L.; Mukhanova, A. A.
2009-04-01
It is widely accepted that metamorphic basement of the Greater Caucasus is essentially Proterozoic [i.e. Gamkrelidze & Shengelia, 2005 ]. New results of geochronological study, mainly on magmatic zircon, contradict this opinion [Somin, 2007; Somin et al., 2007a, b, c and references therein]. To precise age of metamorphism we tried to apply CHIME method on monazite [Suzuki, Adachi, 1991]. The facility consists of Tescan SEM VEGA II xmu equipped with EDS Energy 400 and WDS Wave 500 from Oxford Instruments. This system and analytical protocol for monazite analysis are close to described by Slagstad [2006]. Samples of three metamorphic units were used with purpose to investigate their PT conditions and chemical composition of accessory monazite, xenotime and zircon. In the Blyb Complex Ky-bearing St-Grt-Bt schist was studied. Temperature calculated using Grt-St and Grt-Bt thermometers are 550-600 oC at 10 kb. Because xenotime absence and very low Y2O3 content in monazite, temperature determination on Mnz thermometer was impossible. Isochron chemical age of monazite is 288±24 Ma. In the Gondary Complex the Sil-bearing Grt-Bt gneiss was studied. Temperature calculated using Grt-Bt thermometer and Grt-Pl-Sil-Qtz geobarometer correspond to 610 oC at 4 kb. Monazite thermometer [Pyle et al., 2001] indicates temperature range 533-640 oC for three samples. Monazite chemical age is 303±31 Ma, zircon of leucosome yields SHRIMP age 321-288 Ma. In the Makera Complex the And-Bt-Ms and Grt-Bt-Ms metapelites were examinated. Temperature calculated using Grt-Bt thermometer and Grt-Pl-And-Qtz geobarometer correspond to 500 oC at 2,5 kb. Monazite thermometer indicates average temperatures 293-433-447 oC. Two isochrones correspond to 239±28 Ma and 282±19 Ma. Our results of monazite dating are close to the U-Pb zircon data although not similar being some younger. Therefore conclusion on Precambrian metamorphic events in the studied complexes of the Greater Caucasus is erroneous. These complexes independently of baric type seem to be formed roughly synchronously during Variscan epoch. References: Gamkrelidze I.P., Shengelia D.M. ( 2005).The Precambrian-Paleozoic Regional Metamorphism, Granitoid Magmatism, and Geodynamics of the Caucasus. M: Nauchnyi Mir [in Russian]. Pyle J.M., Frank S. Spear F.S. et al. (2001). Monazite-Xenotime-Garnet Equilibrium in Metapelites and a New Monazite-Garnet Thermometer. Journal of Petrology, , 42, 2083-2107. Slagstad T. (2006).Chemical (U-Th-Pb) dating of monazite: Analytical protocol for a LEO 1450VP scanning electron microscope and examples from Rogaland and Finnmark, Norway. Norges geologiske undersøkelse Bulletin, 446, 11-18. Somin M.L. (2007a). Pre-Alpine basement of the Greater Caucasus: main features. In: Alpine history of the Greater Caucasus (Yu.G. Leonovб Ed.). GEOS. Moscow. P.15-38. Somin M.L., Lepekhina E.N., Konilov A.N. ( 2007b). Age of the High-Temperature Gneiss Core of the Central Caucasus. Doklady Earth Sciences, 415, 690-694. Somin M.L., Levchenkov O.A., Kotov A.B. et al. (2007c). The Paleozoic Age of High-Pressure Metamorphic Rocks in the Dakhov Salient, North-Western Caucasus: Results of U-Pb Geochronological Investigations. Doklady Earth Sciences, 416, 1018-1021. Suzuki K., Adachi M. (1991). Precambrian provenance and Silurian metamorphism of the Tsunosava paragneiss in South Kitakami terrane, northeast Japan, revealed by the chemical Th-U-total Pb isochron ages of monazite, zircon and xenotime. Journal of Geochemistry, 25, 357-376.
McFarland, Daniel C; Shaffer, Kelly M; Polizzi, Heather; Mascarenhas, John; Kremyanskaya, Marina; Holland, Jimmie; Hoffman, Ronald
2018-01-31
The physical symptom burden of patients with myeloproliferative neoplasms (MPNs) may last for extended periods during their disease trajectories and lead to psychologic distress, anxiety, or depression or all of these. This study evaluated the relationship between physical symptom burden captured by the Physical Problem List (PPL) on the Distress Thermometer and Problem List and psychologic outcomes (distress, anxiety, and depression) in the MPN setting. Patients (N = 117) with MPNs completed questionnaires containing the Distress Thermometer and Problem List and the Hospital Anxiety and Depression Scale in a dedicated MPN clinic within an academic medical center. They reported symptoms from any of 22 physical problems on the PPL. Items endorsed by more than 10% of participants were assessed for their associations with distress (Distress Thermometer and Problem List), anxiety (Hospital Anxiety and Depression Scale-Anxiety), and depression (Hospital Anxiety and Depression Scale-Depression). The total number of endorsed PPL items per participant was also evaluated. Nine of 22 PPL items (fatigue, sleep, pain, dry skin/pruritus, memory/concentration, feeling swollen, breathing, and sexual) were reported by >10% of participants. In univariate analyses, all PPL items but one were associated with distress and depression, and all but 2 were associated with anxiety. In multivariate analyses, the total number of PPL items was associated with depression only (p < 0.001) when controlling for covariates. Physical symptom burden in MPN patients was clearly associated with psychologic symptoms. Depression was uniquely associated with overall physical symptom burden. As such, the endorsement of multiple PPL items on the Distress Thermometer and Problem List should prompt an evaluation for psychologic symptoms to improve MPN patients' overall morbidity and quality of life. Copyright © 2018 The Academy of Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.
Performance of Different Light Sources for the Absolute Calibration of Radiation Thermometers
NASA Astrophysics Data System (ADS)
Martín, M. J.; Mantilla, J. M.; del Campo, D.; Hernanz, M. L.; Pons, A.; Campos, J.
2017-09-01
The evolving mise en pratique for the definition of the kelvin (MeP-K) [1, 2] will, in its forthcoming edition, encourage the realization and dissemination of the thermodynamic temperature either directly (primary thermometry) or indirectly (relative primary thermometry) via fixed points with assigned reference thermodynamic temperatures. In the last years, the Centro Español de Metrología (CEM), in collaboration with the Instituto de Óptica of Consejo Superior de Investigaciones Científicas (IO-CSIC), has developed several setups for absolute calibration of standard radiation thermometers using the radiance method to allow CEM the direct dissemination of the thermodynamic temperature and the assignment of the thermodynamic temperatures to several fixed points. Different calibration facilities based on a monochromator and/or a laser and an integrating sphere have been developed to calibrate CEM's standard radiation thermometers (KE-LP2 and KE-LP4) and filter radiometer (FIRA2). This system is based on the one described in [3] placed in IO-CSIC. Different light sources have been tried and tested for measuring absolute spectral radiance responsivity: a Xe-Hg 500 W lamp, a supercontinuum laser NKT SuperK-EXR20 and a diode laser emitting at 6473 nm with a typical maximum power of 120 mW. Their advantages and disadvantages have been studied such as sensitivity to interferences generated by the laser inside the filter, flux stability generated by the radiant sources and so forth. This paper describes the setups used, the uncertainty budgets and the results obtained for the absolute temperatures of Cu, Co-C, Pt-C and Re-C fixed points, measured with the three thermometers with central wavelengths around 650 nm.
Formation of fast-spreading lower oceanic crust as revealed by a new Mg-REE coupled geospeedometer
NASA Astrophysics Data System (ADS)
Sun, Chenguang; Lissenberg, C. Johan
2018-04-01
A new geospeedometer is developed based on the differential closures of Mg and rare earth element (REE) bulk-diffusion between coexisting plagioclase and clinopyroxene. By coupling the two elements with distinct bulk closure temperatures, this speedometer can numerically solve the initial temperatures and cooling rates for individual rock samples. As the existing Mg-exchange thermometer was calibrated for a narrow temperature range and strongly relies on model-dependent silica activities, a new thermometer is developed using literature experimental data. When the bulk closure temperatures of Mg and REE are determined, respectively, using this new Mg-exchange thermometer and the existing REE-exchange thermometer, this speedometer can be implemented for a wide range of compositions, mineral modes, and grain sizes. Applications of this new geospeedometer to oceanic gabbros from the fast-spreading East Pacific Rise at Hess Deep reveal that the lower oceanic crust crystallized at temperatures of 998-1353 °C with cooling rates of 0.003-10.2 °C/yr. Stratigraphic variations of the cooling rates and crystallization temperatures support deep hydrothermal circulations and in situ solidification of various replenished magma bodies. Together with existing petrological, geochemical and geophysical evidence, results from this new speedometry suggest that the lower crust formation at fast-spreading mid-ocean ridges involves emplacement of primary mantle melts in the deep section of the crystal mush zone coupled with efficient heat removal by crustal-scale hydrothermal circulations. The replenished melts become chemically and thermally evolved, accumulate as small magma bodies at various depths, feed the shallow axial magma chamber, and may also escape from the mush zone to generate off-axial magma lenses.
Fabrication of a Cryogenic Terahertz Emitter for Bolometer Focal Plane Calibrations
NASA Technical Reports Server (NTRS)
Chervenak, James; Brown, Ari; Wollack, Edward
2012-01-01
A fabrication process is reported for prototype emitters of THz radiation, which operate cryogenically, and should provide a fast, stable blackbody source suitable for characterization of THz devices. The fabrication has been demonstrated and, at the time of this reporting, testing was underway. The emitter is similar to a monolithic silicon bolometer in design, using both a low-noise thermometer and a heater element on a thermally isolated stage. An impedance-matched, high-emissivity coat ing is also integrated to tune the blackbody properties. This emitter is designed to emit a precise amount of power as a blackbody spectrum centered on terahertz frequencies. The emission is a function of the blackbody temperature. An integrated resistive heater and thermometer system can control the temperature of the blackbody with greater precision than previous incarnations of calibration sources that relied on blackbody emission. The emitter is fabricated using a silicon- on-insulator substrate wafer. The buried oxide is chosen to be less than 1 micron thick, and the silicon device thickness is 1-2 microns. Layers of phosphorus compensated with boron are implanted into and diffused throughout the full thickness of the silicon device layer to create the thermometer and heater components. Degenerately doped wiring is implanted to connect the devices to wire-bondable contact pads at the edge of the emitter chip. Then the device is micromachined to remove the thick-handle silicon behind the thermometer and heater components, and to thermally isolate it on a silicon membrane. An impedance- matched emissive coating (ion assisted evaporated Bi) is applied to the back of the membrane to enable high-efficiency emission of the blackbody spectrum.
Stability of some epoxy-encapsulated diode thermometers
NASA Technical Reports Server (NTRS)
Mangum, B. W.; Evans, G. A., Jr.
1986-01-01
The stability upon thermal cycling and handling of ten small, epoxy-encapsulated silicon diode thermometers at six temperatures in the range from liquid nitrogen temperatures to about 60 C. The nominal temperatures of measurement were -196, -78, 0, 20, 40, and 60 C, as measured on the International Practical Temperature Scale of 1968. Diodes were to be thermally cycled 15 to 20 times. Since NASA anticipates that the uncertainty in their temperature measurements will be + or - 50 mK, uncertainties as large as + or - 10 mK in the measurements of the evaluaton can be accommodated without deleteriously affecting the value of the results of the investigation.
A Field Assessment of a Prototype Meter for Measuring the Wet-Bulb Globe-Thermometer Index
Walters, J. D.
1968-01-01
A prototype electronic instrument for the direct measurement of the wet-bulb globe-thermometer index is described. An assessment is made of its accuracy, as compared with W.B.G.T. indices calculated from conventional thermometric data, and a comparison is made between W.B.G.T. values read from the meter and effective or corrected effective temperatures derived from separate thermometric and air velocity recording instruments in the same climates. The instrument proved to be reliable and accurate over a wide range of climates and is a useful self-contained device for use in habitability surveys and similar investigations. Images PMID:5663429
Ratiometric near infrared luminescent thermometer based on lanthanide metal-organic frameworks
NASA Astrophysics Data System (ADS)
Yue, Dan; Zhang, Jun; Zhao, Dian; Lian, Xiusheng; Cui, Yuanjing; Yang, Yu; Qian, Guodong
2016-09-01
A near infrared luminescent MOFs thermometer (Nd0.676Yb0.324BTC) was prepared via a simple solvothermal method using Ln3+ (Ln=Nd, Yb) ions and 1, 3, 5-benznenetricarboxylic acid (H3BTC), and characterized by PXRD, TGA, ICP, and photoluminescence (PL) spectrum. These results indicate that the Nd0.676Yb0.324BTC displays high relative sensitivity and excellent repeatability in the physiological temperature range (288-323 K), and the maximum relative sensitivity is determined to be 1.187% K-1 at 323 K. These NIR luminescent MOFs may have potential applications in physiological temperature sensing.
Predictive sensor method and apparatus
NASA Technical Reports Server (NTRS)
Cambridge, Vivien J.; Koger, Thomas L.
1993-01-01
A microprocessor and electronics package employing predictive methodology was developed to accelerate the response time of slowly responding hydrogen sensors. The system developed improved sensor response time from approximately 90 seconds to 8.5 seconds. The microprocessor works in real-time providing accurate hydrogen concentration corrected for fluctuations in sensor output resulting from changes in atmospheric pressure and temperature. Following the successful development of the hydrogen sensor system, the system and predictive methodology was adapted to a commercial medical thermometer probe. Results of the experiment indicate that, with some customization of hardware and software, response time improvements are possible for medical thermometers as well as other slowly responding sensors.
NASA Astrophysics Data System (ADS)
Keawprasert, T.; Anhalt, K.; Taubert, D. R.; Sperling, A.; Schuster, M.; Nevas, S.
2013-09-01
An LP3 radiation thermometer was absolutely calibrated at a newly developed monochromator-based set-up and the TUneable Lasers in Photometry (TULIP) facility of PTB in the wavelength range from 400 nm to 1100 nm. At both facilities, the spectral radiation of the respective sources irradiates an integrating sphere, thus generating uniform radiance across its precision aperture. The spectral irradiance of the integrating sphere is determined via an effective area of a precision aperture and a Si trap detector, traceable to the primary cryogenic radiometer of PTB. Due to the limited output power from the monochromator, the absolute calibration was performed with the measurement uncertainty of 0.17 % (k = 1), while the respective uncertainty at the TULIP facility is 0.14 %. Calibration results obtained by the two facilities were compared in terms of spectral radiance responsivity, effective wavelength and integral responsivity. It was found that the measurement results in integral responsivity at the both facilities are in agreement within the expanded uncertainty (k = 2). To verify the calibration accuracy, the absolutely calibrated radiation thermometer was used to measure the thermodynamic freezing temperatures of the PTB gold fixed-point blackbody.
Cross-correlation limit of a SQUID-based noise thermometer of the pMFFT type
NASA Astrophysics Data System (ADS)
Kirste, A.; Engert, J.
2018-03-01
The primary magnetic field fluctuation thermometer (pMFFT) is a SQUID-based noise thermometer for temperatures below 1 K, which complies with metrological requirements. It combines two signal channels in order to apply the cross-correlation technique, but it requires statistically independent noise signals for proper operation. In order to check the limit of the cross-correlation readout, we have performed zero measurements in the millikelvin range in a setup that is identical to the pMFFT, except for the removed temperature sensor. We examined the influence of different parameters such as SQUID working point or flux-lock loop parameters on the minimum cross-correlation signal down to 24 mK and below 100 kHz. Depending on the configuration, typical minimum SQUID-referred cross-power spectral densities of 1.5 × 10‑15 Φ _0^2/Hz or even smaller values were observed. For the pMFFT, considering its thermal noise spectrum, these flux densities correspond to a device noise temperature of ≤2.5 µK, thereby ensuring a negligible uncertainty contribution at the lower end of the PLTS-2000 (0.9 mK).
Definition study for an advanced cosmic ray experiment utilizing the long duration exposure facility
NASA Astrophysics Data System (ADS)
Price, P. B.
1982-06-01
To achieve the goals of cosmic ray astrophysics, an ultraheavy cosmic ray experiment on an LDEF reflight should be in an orbit with high inclination (approximately 57 deg) at approximately 230 nm for approximately 2 years near solar minimum (approximately 1986). It should fill 61 trays. Each tray should contain 4 modules of total active area 0.7 sq m, with a thermal blanket, thermal labyrinth mounts, aluminum honeycomb mechanical support, and total weight approximately 100 kg. Each module should contain interleaved CR39, Lexan, and thin copper sheets plus one event-thermometer canned in a thin metal cannister sealed with approximately 0.2 atm dry O2. The CR39 and Lexan should be manufactured to specifications and the sheet copper rolled to specifications. The event-thermometer should be a stiffened CR39 sheet that slides via bimetal strips relative to fixed CR39 sheet so that stack temperature can be read out for each event. The metal cannister can be collapsed at launch and landing, capturing the sliding assembly to prevent damage. An engineering study should be made of a prototype LDEF tray; this will include thermal and mechanical tests of detectors and the event thermometer.
Definition study for an advanced cosmic ray experiment utilizing the long duration exposure facility
NASA Technical Reports Server (NTRS)
Price, P. B.
1982-01-01
To achieve the goals of cosmic ray astrophysics, an ultraheavy cosmic ray experiment on an LDEF reflight should be in an orbit with high inclination (approximately 57 deg) at approximately 230 nm for approximately 2 years near solar minimum (approximately 1986). It should fill 61 trays. Each tray should contain 4 modules of total active area 0.7 sq m, with a thermal blanket, thermal labyrinth mounts, aluminum honeycomb mechanical support, and total weight approximately 100 kg. Each module should contain interleaved CR39, Lexan, and thin copper sheets plus one event-thermometer canned in a thin metal cannister sealed with approximately 0.2 atm dry O2. The CR39 and Lexan should be manufactured to specifications and the sheet copper rolled to specifications. The event-thermometer should be a stiffened CR39 sheet that slides via bimetal strips relative to fixed CR39 sheet so that stack temperature can be read out for each event. The metal cannister can be collapsed at launch and landing, capturing the sliding assembly to prevent damage. An engineering study should be made of a prototype LDEF tray; this will include thermal and mechanical tests of detectors and the event thermometer.
Optimization of the R-SQUID noise thermometer
NASA Astrophysics Data System (ADS)
Seppä, Heikki
1986-02-01
The Josephson junction can be used to convert voltage into frequency and thus it can be used to convert voltage fluctuations generated by Johnson noise in a resistor into frequency fluctuations. As a consequence, the temperature of the resistor can be defined by measuring the variance of the frequency fluctuations. Unfortunately, the absolute determination of temperature by this approach is disturbed by several undesirable effects: a rolloff introduced by the bandwidth of the postdetection filter, additional noise caused by rf amplifiers, and a mixed noise effect caused by the nonlinearity of the Josephson junction together with rf noise in the tank circuit. Furthermore, the variance is a statistical quantity and therefore the limited number of frequency counts produces inaccuracy in a temperature measurement. In this work the total inaccuracy of the noise thermometer is analyzed and the optimal choice of the parameters is derived. A practical way to find the optimal conditions for the Josephson junction noise thermometer is discussed. The inspection shows that under the optimal conditions the total error is dependent only on the temperature under determination, the equivalent noise temperature of the preamplifier, the bias frequency of the SQUID, and the total time used for the measurement.
Muranaka, Hiroyuki; Nakamura, Osamu; Usui, Shuji; Ueda, Yoshitake; Morikawa, Kaoru
2005-07-20
It is increasingly the case that patients who have implants feel pain during high-field MRI examinations. A probable reason for the pain is the generation by irradiation of RF pulses and changing of the magnetic field gradient. As a fundamental study on the effect of implants on the human body under MRI procedures, temperature measurements were obtained from metal balls incorporated into gel-filled phantoms by using two kinds of measuring instruments, a copper-constantan thermocouple and a fluorescence fiber thermometer. At first we pursued a correlation between a copper-constantan thermocouple (absolute measurement) and fluoroptic thermometer and confirmed the precision and stability of the fluoroptic thermometer under MRI procedures. When a stainless steel ball with or without a loop antenna was used, only in the former case did the temperature rise during RF pulse irradiation. There was no significant difference between the magnetic field gradient ON and OFF. Furthermore, differences in metal (steel, aluminum, brass, stainless steel, copper) and size (5, 10, 20 mmPhi) were affected according to the increase of temperature. In conclusion, both RF pulse irradiation and a loop antenna are necessary for heat generation on the surface of metals.
Development of a low-cost temperature data monitoring. An upgrade for hot box apparatus
NASA Astrophysics Data System (ADS)
de Rubeis, T.; Nardi, I.; Muttillo, M.
2017-11-01
The monitoring phase has gained a fundamental role in the energy efficiency evaluation of a system. Number and typology of the probes depend on the physical quantity to be monitored, and on the size and complexity of the system. Moreover, a measurement equipment should be designed to allow the employment of probes different for number and measured physical quantities. For this reason, a scalable equipment represents a good way for easily carrying out a system monitoring. Proprietary software and high costs characterize instruments of current use, thus limiting the possibilities to realize customized monitoring. In this paper, a temperature measuring instrument, conceived, designed, and realized for real time applications, is presented. The proposed system is based on digital thermometers and on open-source code. A remarkable feature of the instrument is the possibility of acquiring data from a high and variable number of probes (order of hundred), assuring flexibility of the software, since it can be programmed, and low-cost of the hardware components. The contemporary use of multiple temperature probes suggested to apply this instrument for a hot box apparatus, although the software can be set for recording different physical quantities. A hot box compliant with standard EN ISO 8990 should be equipped with several temperature probes to investigate heat exchanges of a specimen wall and thermal field of the chambers. In this work, preliminary tests have been carried out focusing only on the evaluation of the prototypal system’s performance. The tests were realized by comparing different sensors, such as thermocouples and resistance thermometers, traditionally employed in hot box experiments. A preliminary test was realized imposing a dynamic condition with a thermoelectric Peltier cell. Data obtained by digital thermometers DS18B20, compared with the ones of Pt100 probes, show a good correlation. Based on these encouraging results, a further test was carried out in hot box, comparing the data measured by digital thermometers, Pt100 and T-type thermocouples. In this case also, the analyses show a good correlation between either digital thermometers and analog sensors. From these results, it is reasonable to foresee that this measuring instrument could help those willing to realize or refurbish a hot box apparatus, and those who want to undertake temperature monitoring.
A melting-point-of gallium apparatus for thermometer calibration.
Sostman, H E; Manley, K A
1978-08-01
We have investigated the equilibrium melting point of gallium as a temperature fixed-point at which to calibrate small thermistor thermometers, such as those used to measure temperature in enzyme reaction analysis and other temperature-dependent biological assays. We have determined that the melting temperature of "6N" (99.999% pure) gallium is 29.770 +/- 0.002 degrees C, and that the constant-temperature plateau can be prolonged for several hours. We have designed a simple automated apparatus that exploits this phenomenon and that permits routine calibration verification of thermistor temperature probes throughout the laboratory day. We describe the physics of the gallium melt, and the design and use of the apparatus.
Superconducting gamma and fast-neutron spectrometers with high energy resolution
Friedrich, Stephan; , Niedermayr, Thomas R.; Labov, Simon E.
2008-11-04
Superconducting Gamma-ray and fast-neutron spectrometers with very high energy resolution operated at very low temperatures are provided. The sensor consists of a bulk absorber and a superconducting thermometer weakly coupled to a cold reservoir, and determines the energy of the incident particle from the rise in temperature upon absorption. A superconducting film operated at the transition between its superconducting and its normal state is used as the thermometer, and sensor operation at reservoir temperatures around 0.1 K reduces thermal fluctuations and thus enables very high energy resolution. Depending on the choice of absorber material, the spectrometer can be configured either as a Gamma-spectrometer or as a fast-neutron spectrometer.
Thundat, Thomas G.; Oden, Patrick I.; Datskos, Panagiotis G.
2000-01-01
A non-contact infrared thermometer measures target temperatures remotely without requiring the ratio of the target size to the target distance to the thermometer. A collection means collects and focusses target IR radiation on an IR detector. The detector measures thermal energy of the target over a spectrum using micromechanical sensors. A processor means calculates the collected thermal energy in at least two different spectral regions using a first algorithm in program form and further calculates the ratio of the thermal energy in the at least two different spectral regions to obtain the target temperature independent of the target size, distance to the target and emissivity using a second algorithm in program form.
NASA Astrophysics Data System (ADS)
Singh, Y. P.; Maas, H.; Edler, F.; Zaidi, Z. H.
1994-01-01
A set of resistance ratios (W) for platinum resistance thermometers was obtained at the triple point of Hg and the melting point of Ga in order to study their relationship. It was found that using measured values for one of the fixed points, a linear equation will predict the value of the other. These measurements also indicate that the fixed points of Hg and of Ga are inconsistent by about 1,5 mK in the sense that either the melting point of Ga or the triple point of Hg was assigned too high a value on the ITS-90.
High Resolution Thermometry for EXACT
NASA Technical Reports Server (NTRS)
Panek, J. S.; Nash, A. E.; Larson, M.; Mulders, N.
2000-01-01
High Resolution Thermometers (HRTs) based on SQUID detection of the magnetization of a paramagnetic salt or a metal alloy has been commonly used for sub-nano Kelvin temperature resolution in low temperature physics experiments. The main applications to date have been for temperature ranges near the lambda point of He-4 (2.177 K). These thermometers made use of materials such as Cu(NH4)2Br4 *2H2O, GdCl3, or PdFe. None of these materials are suitable for EXACT, which will explore the region of the He-3/He-4 tricritical point at 0.87 K. The experiment requirements and properties of several candidate paramagnetic materials will be presented, as well as preliminary test results.
Method for in-situ restoration of plantinum resistance thermometer calibration
Carroll, Radford M.
1989-01-01
A method is provided for in-situ restoration of platinum resistance thermometers (PRT's) that have undergone surface oxide contamination and/or strain-related damage causing decalibration. The method, which may be automated using a programmed computer control arrangement, consists of applying a dc heating current to the resistive sensing element of the PRT of sufficient magnitude to heat the element to an annealing temperature and maintaining the temperature for a specified period to restore the element to a stress-free calibration condition. The process anneals the sensing element of the PRT without subjecting the entire PRT assembly to the annealing temperature and may be used in the periodic maintenance of installed PRT's.
Method for in-situ restoration of platinum resistance thermometer calibration
Carroll, R.M.
1987-10-23
A method is provided for in-situ restoration of platinum resistance thermometers (PRT's) that have undergone surface oxide contamination and/or stain-related damage causing decalibration. The method, which may be automated using a programmed computer control arrangement, consists of applying a dc heating current to the resistive sensing element of the PRT of sufficient magnitude to heat the element to an annealing temperature and maintaining the temperature for a specified period to restore the element to a stress-free calibration condition. The process anneals the sensing element of the PRT without subjecting the entire PRT assembly to the annealing temperature and may be used in the periodic maintenance of installed PRT's. 1 fig.
Quartz Crystal Temperature Sensor for MAS NMR
NASA Astrophysics Data System (ADS)
Simon, Gerald
1997-10-01
Quartz crystal temperature sensors (QCTS) were tested for the first time as wireless thermometers in NMR MAS rotors utilizing the NMR RF technique itself for exiting and receiving electro-mechanical quartz resonances. This new tool in MAS NMR has a high sensitivity, linearity, and precision. When compared to the frequently used calibration of the variable temperature in the NMR system by a solid state NMR chemical shift thermometer (CST), such as lead nitrate, QCTS shows a number of advantages. It is an inert thermometer in close contact with solid samples operating parallel to the NMR experiment. QCTS can be manufactured for any frequency to be near a NMR frequency of interest (typically 1 to 2 MHz below or above). Due to the strong response of the crystal, signal detection is possible without changing the tuning of the MAS probe. The NMR signal is not influenced due to the relative sharp crystal resonance, restricted excitation by finite pulses, high probeQvalues, and commonly used audio filters. The quadratic dependence of the temperature increase on spinning speed is the same for the QCTS and for the CST lead nitrate and is discussed in terms of frictional heat in accordance with the literature about lead nitrate and with the results of a simple rotor speed jump experiment with differently radial located lead nitrate in the rotor.
Performance and Characterization of Magnetic Penetration Thermometer Devices for X-Ray Spectroscopy
NASA Technical Reports Server (NTRS)
Porst, J. -P.; Adams, J. S.; Bandler, S. R.; Balvin, M.; Busch, S. E.; Denis, K. L.; Kelly, D.; Nagler, P.; Sadleir, J. E.; Seidel, G. M.;
2012-01-01
We are developing magnetic penetration thermometers (MPTs) for applications in X-ray astronomy. These non-dissipative devices consist of an X-ray absorber in good thermal contact to a superconducting thin film with a transition temperature around T=100mK. A microfabricated superconducting planar inductor underneath is used to store a persistent current and couple the superconductor's diamagnetic response to a readout SQUID. The strong temperature dependence of the diamagnetic response make these devices suitable for highly sensitive macroscopic thermometers that are capable of achieving very high energy resolution. We present results achieved with MPTs consisting of MoAu bilayer sensors attached to overhanging square 250 micron by 250 micron gold absorbers that have demonstrated an energy resolution of delta E_FWHM=2.3eV at an X-ray energy of 5.9keV. A similar device has shown delta E_FWHM=2.0eV at 1.5 keV. Under certain conditions and for specific device geometries, the temperature responsivity of the MPTs can vary on long timescales degrading the spectral performance. We present the characterization of different inductor geometries to optimize the design for the highest possible temperature sensitivity and compare different device designs with respect to responsivity stability.
Boys who pee the farthest have a large hollow head, a thin skin, and medium-size manhood
NASA Astrophysics Data System (ADS)
Attinger, Daniel; Lee, Vincent
2016-11-01
Following a recent trend of scientific studies on artwork, we study here the thermodynamics of a jetting thermometer made of ceramic, related to the Chinese tea culture. The thermometer represents a boy who "urinates" shortly after hot water is poured onto his head. Long jetting distance indicates if the water temperature is hot enough to brew tea. Here, a thermofluid model describes the jetting phenomenon of that pee-pee boy. The study demonstrates how thermal expansion of an interior air pocket causes jetting. The validity of assumptions underlying the Hagen-Poiseuille flow is discussed for urethra of finite length. A thermodynamic potential is shown to define maximum jetting velocity. Seven optimization criteria to maximize jetting distance are provided, including two dimensionless numbers. The dimensionless numbers are obtained by comparing the time scales of the internal pressure buildup due to heating, with that of pressure relief due to jetting. Optimization results show that longer jets are produced by large individuals, with low body mass index, with a boyhood of medium size inclined at an angle π/4. Analogies are drawn with pissing contests among humans and lobsters. The study ends by noting similitudes of working principle between that politically incorrect thermometer and Galileo Galilei's thermoscope.
NIM gas controlled sodium heat pipe
NASA Astrophysics Data System (ADS)
Yan, X.; Zhang, J. T.; Merlone, A.; Duan, Y.; Wang, W.
2013-09-01
Gas controlled heat pipes (GCHPs) provide a uniform, stable and reproducible temperature zone to calibrate thermometers and thermocouples, and to realize defining fixed points using a calorimetric method. Therefore, to perform such investigations, a GCHP furnace using sodium as its working fluid was constructed at the National Institute of Metrology (NIM), China. Also, investigations into the thermal characteristics of the NIM gas controlled sodium heat pipe were carried out. The temperature stability over 5 hours was better than ±0.25 mK while controlling the pressure at 111250 Pa. The temperature uniformity within 14 cm from the bottom of the thermometer well was within 0.3 mK. While keeping the pressure stable at the same value, 17 temperature determinations were performed over 14 days, obtaining a temperature reproducibility of 1.27 mK. Additionally, the NIM gas controlled sodium heat pipe was compared with the sodium heat pipe produced by INRiM. The temperature in the INRiM sodium heat pipe operating at 111250 Pa was determined, obtaining a difference of 21 mK with respect to the NIM GCHP. This difference was attributed to sodium impurities, pressure controller capabilities and reproducibility, and instabilities of high temperature standard platinum resistance thermometers (HTSPRTs). Further investigations will be carried out on extending the pressure/temperature range and connecting both GCHPs to the same pressure line.
A two-beam acoustic system for tissue analysis.
Sachs, T D; Janney, C D
1977-03-01
In the 'thermo-acoustic sensing technique' (TAST), a burst of sound, called the 'thermometer' beam is passed through tissue and its transit time is measured. A focused sound field, called the heating field, then warms a small volume in the path of the therometer beam, in proportion to the absorption. Finally, the therometer beam burst is repeated and its transit time subtracted from that of the initial thermometer burst. This difference measures the velocity perturbation in the tissue produced by the heating field. The transit time difference is td = K integral of infinity-infinity IP dchi where K is the instrument constant, I the heating field intensity, and P a perturbation factor which characterizes the tissues. The integration is carried out along the path of the thermometer beam. The perturbation factor is P = (formula: see text) where C is the specific heat, rho the denisty, V the velocity of sound, (formula: see text) the temperature coefficient of velocity and alpha the heating field absorption coefficient which is apparently sensitive to tissue structure and condition. Experiments on a fixed human brain showed an ability to distinguish between various tissue types combined with a spatial resolution of better than 3 mm. Should predictions based on the data and theory prove correct, TAST may become a non-invasive alternative to biopsy.
A High-Emissivity Blackbody with Large Aperture for Radiometric Calibration at Low-Temperature
NASA Astrophysics Data System (ADS)
Ko, Hsin-Yi; Wen, Bor-Jiunn; Tsa, Shu-Fei; Li, Guo-Wei
2009-02-01
A newly designed high-emissivity cylindrical blackbody source with a large diameter aperture (54 mm), an internal triangular-grooved surface, and concentric grooves on the bottom surface was immersed in a temperature-controlled, stirred-liquid bath. The stirred-liquid bath can be stabilized to better than 0.05°C at temperatures between 30 °C and 70 °C, with traceability to the ITS-90 through a platinum resistance thermometer (PRT) calibrated at the fixed points of indium, gallium, and the water triple point. The temperature uniformity of the blackbody from the bottom to the front of the cavity is better than 0.05 % of the operating temperature (in °C). The heat loss of the cavity is less than 0.03 % of the operating temperature as determined with a radiation thermometer by removing an insulating lid without the gas purge operating. Optical ray tracing with a Monte Carlo method (STEEP 3) indicated that the effective emissivity of this blackbody cavity is very close to unity. The size-of-source effect (SSE) of the radiation thermometer and the effective emissivity of the blackbody were considered in evaluating the uncertainty of the blackbody. The blackbody uncertainty budget and performance are described in this paper.
Sued, Bruna Pinto Ribeiro; Pereira, Paula Marcele Afonso; Faria, Yuri Vieira; Ramos, Juliana Nunes; Binatti, Vanessa Batista; Santos, Kátia Regina Netto Dos; Seabra, Sérgio Henrique; Hirata, Raphael; Vieira, Verônica Viana; Mattos-Guaraldi, Ana Luíza; Pereira, José Augusto Adler
2017-03-01
The association between Staphylococcus haemolyticus and severe nosocomial infections is increasing. However, the extent to which fomites contribute to the dissemination of this pathogen through patients and hospital wards remains unknown. In the present study, sphygmomanometers and thermometers were evaluated as potential fomites of oxacillin-resistant S. haemolyticus (ORSH). The influence of oxacillin and vancomycin on biofilm formation by ORSH strains isolated from fomites was also investigated. The presence of ORSH on swabs taken from fomite surfaces in a Brazilian hospital was assessed using standard microbiological procedures. Antibiotic susceptibility profiles were determined by the disk diffusion method, and clonal distribution was assessed in pulsed-field gel electrophoresis (PFGE) assays. Minimum inhibitory concentrations (MICs) of oxacillin and vancomycin were evaluated via the broth microdilution method. Polymerase chain reaction (PCR) assays were performed to detect the mecA and icaAD genes. ORSH strains grown in media containing 1/4 MIC of vancomycin or oxacillin were investigated for slime production and biofilm formation on glass, polystyrene and polyurethane catheter surfaces. ORSH strains comprising five distinct PFGE types were isolated from sphygmomanometers (n = 5) and a thermometer (n = 1) used in intensive care units and surgical wards. ORSH strains isolated from fomites showed susceptibility to only linezolid and vancomycin and were characterised as multi-drug resistant (MDR). Slime production, biofilm formation and the survival of sessile bacteria differed and were independent of the presence of the icaAD and mecA genes, PFGE type and subtype. Vancomycin and oxacillin did not inhibit biofilm formation by vancomycin-susceptible ORSH strains on abiotic surfaces, including on the catheter surface. Enhanced biofilm formation was observed in some situations. Moreover, a sub-lethal dose of vancomycin induced biofilm formation by an ORSH strain on polystyrene. Sphygmomanometers and thermometers are fomites for the transmission of ORSH. A sub-lethal dose of vancomycin may favor biofilm formation by ORSH on fomites and catheter surfaces.
Sued, Bruna Pinto Ribeiro; Pereira, Paula Marcele Afonso; Faria, Yuri Vieira; Ramos, Juliana Nunes; Binatti, Vanessa Batista; dos Santos, Kátia Regina Netto; Seabra, Sérgio Henrique; Hirata, Raphael; Vieira, Verônica Viana; Mattos-Guaraldi, Ana Luíza; Pereira, José Augusto Adler
2017-01-01
BACKGROUND The association between Staphylococcus haemolyticus and severe nosocomial infections is increasing. However, the extent to which fomites contribute to the dissemination of this pathogen through patients and hospital wards remains unknown. OBJECTIVES In the present study, sphygmomanometers and thermometers were evaluated as potential fomites of oxacillin-resistant S. haemolyticus (ORSH). The influence of oxacillin and vancomycin on biofilm formation by ORSH strains isolated from fomites was also investigated. METHODS The presence of ORSH on swabs taken from fomite surfaces in a Brazilian hospital was assessed using standard microbiological procedures. Antibiotic susceptibility profiles were determined by the disk diffusion method, and clonal distribution was assessed in pulsed-field gel electrophoresis (PFGE) assays. Minimum inhibitory concentrations (MICs) of oxacillin and vancomycin were evaluated via the broth microdilution method. Polymerase chain reaction (PCR) assays were performed to detect the mecA and icaAD genes. ORSH strains grown in media containing 1/4 MIC of vancomycin or oxacillin were investigated for slime production and biofilm formation on glass, polystyrene and polyurethane catheter surfaces. FINDINGS ORSH strains comprising five distinct PFGE types were isolated from sphygmomanometers (n = 5) and a thermometer (n = 1) used in intensive care units and surgical wards. ORSH strains isolated from fomites showed susceptibility to only linezolid and vancomycin and were characterised as multi-drug resistant (MDR). Slime production, biofilm formation and the survival of sessile bacteria differed and were independent of the presence of the icaAD and mecA genes, PFGE type and subtype. Vancomycin and oxacillin did not inhibit biofilm formation by vancomycin-susceptible ORSH strains on abiotic surfaces, including on the catheter surface. Enhanced biofilm formation was observed in some situations. Moreover, a sub-lethal dose of vancomycin induced biofilm formation by an ORSH strain on polystyrene. MAIN CONCLUSIONS Sphygmomanometers and thermometers are fomites for the transmission of ORSH. A sub-lethal dose of vancomycin may favor biofilm formation by ORSH on fomites and catheter surfaces. PMID:28225903
NASA Astrophysics Data System (ADS)
Tissot, Jean-Luc
2003-12-01
The emergence of uncooled detectors has opened new opportunities for IR detection for both military and commercial applications. Development of such devices involves a lot of trade-offs between the different parameters that define the technological stack. These trade-offs explain the number of different architectures that are under worldwide development. The key factor is to find a high sensitivity and low noise thermometer material compatible with silicon technology in order to achieve high thermal isolation in the smallest area as possible. Ferroelectric thermometer based hybrid technology and electrical resistive thermometer based (microbolometer) technology are under development. LETI and ULIS have chosen from the very beginning to develop first a monolithic microbolometer technology fully compatible with commercially available CMOS technology and secondly amorphous silicon based thermometer. This silicon approach has the greatest potential for reducing infrared detector manufacturing cost. After the development of the technology, the transfer to industrial facilities has been performed in a short period of time and the production is now ramping up with ULIS team in new facilities. LETI and ULIS are now working to facilitate the IRFPA integration into equipment in order to address a very large market. Achievement of this goal needs the development of smart sensors with on-chip advanced functions and the decrease of manufacturing cost of IRFPA by decreasing the pixel pitch and simplifying the vacuum package. We present in this paper the technology developed by CEA/LETI and its improvement for being able to designs 384×288 and 160×120 arrays with a pitch of 35 μm. Thermographic application needs high stability infrared detector with a precise determination of the amount of absorbed infrared flux. Hence, infrared detector with internal temperature stabilized shield has been developed and characterized. These results will be presented. To cite this article: J.-L. Tissot, C. R. Physique 4 (2003).
NASA Astrophysics Data System (ADS)
DePew, K. A.; Ma, C.; Schiffbauer, J. D.; Wang, J.; Dong, B.; Lally, E.; Wang, A.
2012-12-01
The Center for Photonics Technology (CPT) at Virginia Tech is engaged in cutting edge research of fiber optic sensing technologies. One current research area is the design of fiber optic temperature sensors for harsh environments. Fiber optic temperature sensing offers significant advantages over electronic sensing in terms of size and insensitivity to harsh environmental conditions and electromagnetic interference. In the field, fiber optic thermometers have been used in recent snow cover studies as well as fluvial temperature profiling projects. The extended capabilities of CPT optical sensors open further possibilities for application in additional geologic realms requiring high temperature sensing in corrosive environments. Significant strides have been made in developing single-crystal sapphire based fiber optic sensing elements for high temperature environments which are otherwise difficult to instrument. Utilization of strain insensitive designs and optical sapphire materials allow for thermometers capable of operation above 1500°C with reduced sensitivity to chemical corrosion and mechanical interference. Current efforts in fabrication techniques are reducing the footprint of temperature sensors below the millimeter scale while maintaining high resolution and operating range. The FEI Helios 600 NanoLab workstation at the Virginia Tech Institute for Critical Technologies and Applied Science has been employed, providing the capabilities necessary to reduce the footprint of sensing elements to the dimensions of standard optical communication fiber using a Ga+ focused ion beam (FIB). The capability of semi-distributed multi-point sensing can also be accomplished at this scale using similar FIB milling techniques. The fiber optic thermometer designs resulting from these methods are compact, lightweight, and able to provide remote sensing without need for electrical power at the measurement point. These traits make them an ideal sensing platform for laboratory applications with minimal instrumentation egress as well as field deployment in areas where traditional electronic technologies cannot survive.
Honjo, N.; Bonnichsen, B.; Leeman, W.P.; Stormer, J.C.
1992-01-01
Voluminous mid-Miocene rhyolitic ash-flow tuffs and lava flows are exposed along the northern and southern margins of the central and western Snake River Plain. These rhyolites are essentially anhydrous with the general mineral assemblage of plagioclase ??sanidine ?? quartz + augite + pigeonite ?? hypersthene ?? fayalitic olivine + Fe-Ti oxides + apatite + zircon which provides an opportunity to compare feldspar, pyroxene, and Fe-Ti oxide equilibration temperatures for the same rocks. Estimated pyroxene equilibration temperatures (based on the geothermometers of Lindsley and coworkers) range from 850 to 1000??C, and these are well correlated with whole-rock compositions. With the exception of one sample, agreement between the two-pyroxene thermometers tested is well within 50??C. Fe-Ti oxide geothermometers applied to fresh magnetite and ilmenite generally yield temperatures about 50 to 100??C lower than the pyroxene temperatures, and erratic results are obtained if these minerals exhibit effects of subsolidus oxidation and exsolution. Results of feldspar thermometry are more complicated, and reflect uncertainties in the thermometer calibrations as well as in the degree of attainment of equilibrium between plagioclase and sanidine. In general, temperatures obtained using the Ghiorso (1984) and Green and Usdansky (1986) feldspar thermometers agree with the pyroxene temperatures within the respective uncertainties. However, uncertainties in the feldspar temperatures are the larger of the two (and exceed ??60??C for many samples). The feldspar thermometer of Fuhrman and Lindsley (1988) produces systematically lower temperatures for many of the samples studied. The estimated pyroxene temperatures are considered most representative of actual magmatic temperatures for these rhyolites. This range of temperatures is significantly higher than those for rhyolites from many other suites, and is consistent with the hypothesis that the Snake River Plain rhyolitic magmas formed by partial fusion of relatively dry (e.g. granulitic) crustal lithologies. ?? 1992 Springer-Verlag.
[Computerized temperature monitoring of the vaccine cold chain in a tropical climate, Chad].
Schlumberger, M; Mireux, F; Tchang, S G; Mboutbogol, D; Cheikh, D O; Hissein, A A; Youssouf, B O; Brahimi, M M; Gamatié, Y
2011-06-01
Because new EPI liquid vaccines are highly sensitive to freezing and overheating, close monitoring of the cold chain is mandatory. The new Testostore 171-1 electronic thermometer (Testo) provides more reliable monitoring of cold chain temperature than freezer indicators, vaccine vial monitors and color strips that only indicate if vaccines are out-of-date. The Testo thermometer uses a probe placed in refrigeration units to periodically measure and store temperature readings. Temperature curves are displayed via a USB connection on a laptop computer running special software (Comfort software light). Testo temperature data can easily be communicated to all management levels by e-mail. The first experience using the Testo system in Africa involved regional EPI supervision in Mondou, Logone Occidental, Chad. After a preliminary mission in Chad in 2006 showed the feasibility of using this method to manage the national cold chain at all levels, a nurse was appointed as EPI supervisor and given a refresher course in Chad's capital Ndjamena in March 2009. In April-May 2009, the supervisor was sent back to the Logone Occidental Region to monitor, by himself, refrigeration units making up the regional and district cold chain for vaccine storage in five health centers (rural and urban). Temperature curve readings were performed on site in the presence of the medical staff and results were compared to those recorded twice a day on conventional temperature charts using lamellar thermometers installed in refrigerators doors. Testo curves showed that liquid vaccine storage temperatures fell below freezing too frequently and that temperatures readings of door thermometers were often inaccurate. Testo readings also detected power outages in refrigeration units used in urban settings and flame extinctions in kerosene lamp refrigerators due to refrigerator breakdown or windy weather conditions before the rainy season. The main advantage of this monitoring method is to provide reliable data as a basis not only for detection of possible freezing of liquid vaccines but also for discussion of cold chain management and improvement with medical staff.
Allegaert, Karel; Casteels, Kristina; van Gorp, Ilse; Bogaert, Guy
2014-01-01
Introduction Body temperature measurement in children is of clinical relevance. Although rectal measurement is the gold standard, less invasive tools have become available. We aimed to describe the accuracy of tympanic, infrared skin, or temporal artery scan thermometers compared with rectal measurement to reflect core temperature. Methods Rectal (Filac 3000; Covidien, Mechelen, Belgium), tympanic (AccuSystem Genius2 Typmanic Infrared Ear Thermometer, Covidien, Mechelen, Belgium), temporal artery scan (Exergen, Exergen Corp, Watertown, Massachusetts), and infrared (ThermoFlash Contactless Medical Electronic Thermometer, Visiomedlab, Paris, France) body temperature measurements were randomly performed and readings were collected once. Temperature readings were described as median and range, and observations were compared with rectal temperature readings (using Wilcoxon, Bland-Altman, sensitivity, and specificity tests). The child’s comfort was assessed by the child, parent, and nurse (using Likert scales) and ease of use was assessed by nurses (using visual analog scale). Results Based on observations in 294 (median age = 3.2 years, range = 0.02–17 years) children, the mean difference was 0.49°C (tympanic scan; P < 0.0001), 0.34°C (infrared skin scan; P < 0.0001), and 0°C (temporal artery scan; P = 0.9288), respectively, when compared with rectal temperature readings. Based on visual inspection of Bland-Altman plots, all tools overestimated the temperature at lower body temperature and underestimated the temperature at higher body temperature, resulting in a sensitivity of 22% to 41% and a specificity of 98% to 100% for rectal temperatures above 38°C. The Likert scale scores and the visual analog scale scores for rectal measurement were only slightly higher when compared with the other methods. Conclusions All noninvasive techniques underperformed compared with rectal measurement. The temporal artery scan deviations were smallest, but all noninvasive techniques overestimate lower temperatures and underestimate higher temperatures compared with rectal measurement. In our hands, temporal artery scan measurement seems to be second best, but not yet ideal. PMID:25067984
ERIC Educational Resources Information Center
Education in Chemistry, 1976
1976-01-01
Described are a number of publications and items for use in chemistry. Included are brief descriptions of actuators, thermometer strips, current balances, and a variety of catalogues and other publications. (RH)
Evaluation of platinum resistance thermometers
NASA Technical Reports Server (NTRS)
Daryabeigi, Kamran; Dillon-Townes, Lawrence A.
1988-01-01
An evaluation procedure for the characterization of industrial platinum resistance thermometers (PRTs) for use in the temperature range -120 to 160 C was investigated. This evaluation procedure consisted of calibration, thermal stability and hysteresis testing of four surface measuring PRTs. Five different calibration schemes were investigated for these sensors. The IPTS-68 formulation produced the most accurate result, yielding average sensor systematic error of 0.02 C and random error of 0.1 C. The sensors were checked for thermal stability by successive and thermal cycling between room temperature, 160 C, and boiling point of nitrogen. All the PRTs suffered from instability and hysteresis. The applicability of the self-heating technique as an in situ method for checking the calibration of PRTs located inside wind tunnels was investigated.
Stagnation Temperature Recording
NASA Technical Reports Server (NTRS)
Wimmer, W
1941-01-01
The present report deals with the development of a thermometer for recording stagnation temperature in compressible mediums in turbulent flow within 1 to 2 percent error of the adiabatic temperature in the stagnation point, depending upon the speed. This was achieved by placing the junction of a thermocouple near the stagnation point of an aerodynamically beneficial body, special care being taken to assure an uninterrupted supply of fresh compressed air on the junction together with the use of metals of low thermal conductivity, thus keeping heat-transfer and heat-dissipation losses to a minimum. In other experiments the use of the plate thermometer was proved unsuitable for practical measurements by reason of its profound influence in the reading by the Reynolds number and by the direction of flow.
Bilateral Comparison of Blackbodies for Clinical Infrared Ear Thermometers between NIMT and NMIJ
NASA Astrophysics Data System (ADS)
Manoi, A.; Norranim, U.; Kaneko, Y.; Ishii, J.
2014-04-01
This article describes the results of the bilateral comparison of blackbodies for infrared ear thermometers (IRETs) between the National Institute of Metrology (Thailand), NIMT, and the National Metrology Institute of Japan (NMIJ). The purpose of this comparison was to ensure consistency of the national radiance temperature scales for IRETs maintained by NIMT and NMIJ. Results of the measurements indicate differences in radiance temperature within 10 mK with a maximum measurement uncertainty of 64 mK. The equivalence of the radiance temperature scales realized by both NIMT and NMIJ in the range of 35 C to 42 C for IRET calibration is indicated. The results of this bilateral comparison can be used in terms of quality assurance and validation of calibration.
Power spool test, TSH-002, SPTF No. 19
DOE Office of Scientific and Technical Information (OSTI.GOV)
McInturff, A.D.
1982-05-28
The data presented in this Technical Memo will pertain to the operating characteristics of Power Spool TSH-002. This spool had a large number of thermometers built into it. These thermometers monitored most of the thermal characteristics of the 5000 A American Magnetics, Inc. vapor-cooled leads used in this power spool. Operating conditions, such as peak temperatures, ramp and dc lead cooling gas flow requirements, voltage as an indicator of stable conditions (ac and dc) and general voltage characteristics (i.e., amount of ice formed outside of leads vs high-pot voltage) were measured and observed. It was found that previous operating conditionsmore » of the power leads influenced the temperature gradients of the leads in certain cases.« less
Distress in patients with cancer: definition, assessment, and suggested interventions.
Vitek, Leesa; Rosenzweig, Margaret Quinn; Stollings, Susan
2007-06-01
Distress in patients with cancer impacts their quality of life. The National Comprehensive Cancer Network (NCCN) created a distress thermometer and a problem checklist to aid in recognizing distress. The thermometer measures distress on a 0-10 scale, and the problem checklist identifies more specific etiologies of distress, such as practical, spiritual, physical, emotional, and family problems. Oncology nurses play a key role in the success of the distress-screening tool because they have the most patient contact. The NCCN guidelines suggest that patients complete the screening tools at each visit and clinicians review the outcome. NCCN has provided clinical pathways for treating the etiologies of distress using a multidisciplinary approach, including members from social work, pastoral services, mental health, and oncology.
Studying cooling curves with a smartphone
NASA Astrophysics Data System (ADS)
Silva, Manuela Ramos; Martín-Ramos, Pablo; da Silva, Pedro Pereira
2018-01-01
This paper describes a simple procedure for the study of the cooling of a spherical body using a standard thermometer and a smartphone. Experiments making use of smartphone sensors have been described before, contributing to an improved teaching of classical mechanics, but rarely expand to thermodynamics. In this experiment, instead of using a smartphone camera to slow down a fast movement, we are using the device to speed up a slow process. For that we propose the use of the free app Framelapse to take periodic pictures (in the form of a time-lapse video) and then the free app VidAnalysis to track the position of the mercury inside the thermometer, thus effortlessly tracking the temperature of a cooling body (Fig. 1).
ERIC Educational Resources Information Center
Byrum, David L., Ed.
1984-01-01
Describes an electronic thermometer using a precision temperature sensor (includes detailed schematic of circuits) and inexpensive ring holders for round-bottomed flasks. Also describes a method for reducing funnel breakage. (JN)
Heat Management Strategies for Solid-state NMR of Functional Proteins
Fowler, Daniel J.; Harris, Michael J.; Thompson, Lynmarie K.
2012-01-01
Modern solid-state NMR methods can acquire high-resolution protein spectra for structure determination. However, these methods use rapid sample spinning and intense decoupling fields that can heat and denature the protein being studied. Here we present a strategy to avoid destroying valuable samples. We advocate first creating a sacrificial sample, which contains unlabeled protein (or no protein) in buffer conditions similar to the intended sample. This sample is then doped with the chemical shift thermometer Sm2Sn2O7. We introduce a pulse scheme called TCUP (for Temperature Calibration Under Pulseload) that can characterize the heating of this sacrificial sample rapidly, under a variety of experimental conditions, and with high temporal resolution. Sample heating is discussed with respect to different instrumental variables such as spinning speed, decoupling strength and duration, and cooling gas flow rate. The effects of different sample preparation variables are also discussed, including ionic strength, the inclusion of cryoprotectants, and the physical state of the sample (i.e. liquid, solid, or slurry). Lastly, we discuss probe detuning as a measure of sample thawing that does not require retuning the probe or using chemical shift thermometer compounds. Use of detuning tests and chemical shift thermometers with representative sample conditions makes it possible to maximize the efficiency of the NMR experiment while retaining a functional sample. PMID:22868258
NASA Astrophysics Data System (ADS)
Ragay-Enot, Monalisa; Lee, Young Hee; Kim, Yong-Gyoo
2017-07-01
A mini multi-fixed-point cell (length 118 mm, diameter 33 mm) containing three materials (In-Zn eutectic (mass fraction 3.8% Zn), Sn and Pb) in a single crucible was designed and fabricated for the easy and economical fixed-point calibration of industrial platinum resistance thermometers (IPRTs) for use in industrial temperature measurements. The melting and freezing behaviors of the metals were investigated and the phase transition temperatures were determined using a commercial dry-block calibrator. Results showed that the melting plateaus are generally easy to realize and are reproducible, flatter and of longer duration. On the other hand, the freezing process is generally difficult, especially for Sn, due to the high supercooling required to initiate freezing. The observed melting temperatures at optimum set conditions were 143.11 °C (In-Zn), 231.70 °C (Sn) and 327.15 °C (Pb) with expanded uncertainties (k = 2) of 0.12 °C, 0.10 °C and 0.13 °C, respectively. This multi-fixed-point cell can be treated as a sole reference temperature-generating system. Based on the results, the realization of melting points of the mini multi-fixed-point cell can be recommended for the direct calibration of IPRTs in industrial applications without the need for a reference thermometer.
Optical Fiber Thermometer Based on Fiber Bragg Gratings
NASA Astrophysics Data System (ADS)
Rosli, Ekbal Bin; Mohd. Noor, Uzer
2018-03-01
Fiber Bragg grating has generated much interest in use as sensors to measure strain, temperature, and other physical parameters. It also the most common component used to develop this sensor with the advantages of simple, intrinsic sensing elements, electrically passive operation, EMI immunity, high sensitivity, compact size and potentially low cost [6]. This paper reports the design of an optical fiber thermometer based on fiber Bragg gratings. The system was developed for detecting temperature and strain by monitoring the shift of Bragg wavelength. The shifting of Bragg wavelength is used to indicate the temperature and strain due to the change in the surrounding temperature and strain. When the temperature and strain reach the exact wavelength level of the system, the temperature and strain value will display on the Arduino liquid crystal display (LCD). The optical fiber will provide the broadband light source and after passing the FBG the Bragg wavelength into the optical spectrum analyzer (OSA). The system is based on FBG as a physical quantity sensor. The temperatures measured is taken from the water bath and that of the strain is provided by amount of slotted mass used. The outcome of this project is to characterize the Bragg wavelength shifting from the fiber Bragg grating output. As the conclusion, this project provides an efficient optical fiber thermometer in measuring temperature and strain in order to replace the use of conventional electrical instruments.
Ground-based thermal imaging of stream surface temperatures: Technique and evaluation
Bonar, Scott A.; Petre, Sally J.
2015-01-01
We evaluated a ground-based handheld thermal imaging system for measuring water temperatures using data from eight southwestern USA streams and rivers. We found handheld thermal imagers could provide considerably more spatial information on water temperature (for our unit one image = 19,600 individual temperature measurements) than traditional methods could supply without a prohibitive amount of effort. Furthermore, they could provide measurements of stream surface temperature almost instantaneously compared with most traditional handheld thermometers (e.g., >20 s/reading). Spatial temperature analysis is important for measurement of subtle temperature differences across waterways, and identification of warm and cold groundwater inputs. Handheld thermal imaging is less expensive and equipment intensive than airborne thermal imaging methods and is useful under riparian canopies. Disadvantages of handheld thermal imagers include their current higher expense than thermometers, their susceptibility to interference when used incorrectly, and their slightly lower accuracy than traditional temperature measurement methods. Thermal imagers can only measure surface temperature, but this usually corresponds to subsurface temperatures in well-mixed streams and rivers. Using thermal imaging in select applications, such as where spatial investigations of water temperature are needed, or in conjunction with stationary temperature data loggers or handheld electronic or liquid-in-glass thermometers to characterize stream temperatures by both time and space, could provide valuable information on stream temperature dynamics. These tools will become increasingly important to fisheries biologists as costs continue to decline.
NASA Astrophysics Data System (ADS)
Picard, S.; Nonis, M.; Solve, S.; Allisy-Roberts, P. J.; Renaot, E.; Martin, C.
2011-01-01
A comparison of standard platinum resistance thermometers (SPRTs) has been carried out between the BIPM and the Laboratoire commun de métrologie LNE-CNAM using the melting point of gallium and the triple point of water. The temperature difference at Ga between the BIPM and the LNE-CNAM was determined as 108 µK with an associated combined standard uncertainty of 223 µK. This outcome indicates a present temperature difference of the BIPM of -65 µK with respect to an Average Reference Value from an earlier comparison, with an associated uncertainty of uc = 262 µK. It should be noted that the present BIPM scale is not independent, but traceable to cells used in KC7. The comparison results validate the re-establishment of thermometer calibrations at the BIPM for internal use. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Code of Federal Regulations, 2010 CFR
2010-04-01
... quantity of spirits. The proof of the spirits shall be determined using a glass cylinder, hydrometer, and... determine quantity by volume. The proprietor shall ensure that hydrometers, thermometers, and other...
Thermometric Property of a Diode.
ERIC Educational Resources Information Center
Inman, Fred W.; Woodruff, Dan
1995-01-01
Presents a simple way to implement the thermometric property of a semiconductor diode to produce a thermometer with a nearly linear dependence upon temperature over a wide range of temperatures. (JRH)
Use of infrared emission detection thermometer in Chinese neonates.
Ng, D K; Liu, Y S; Ho, J C
1999-07-01
To evaluate the reproducibility of Thermoscan, an infrared emission detection ear thermometer, and to establish the normal reference range of ear temperature in Chinese neonates. Neonates were recruited from the inpatients population with exclusion of those suffering from infections. Forty-nine neonates were recruited with 1,115 temperature taking sessions. Mean left ear temperature was 36.64 degrees C +/- 0.35 degree C. Mean right ear temperature was 36.64 degrees C +/- 0.37 degree C. Clinical repeatability for left and right ear was 0.17 degree C and 0.17 degree C, respectively. Thermoscan produced reproducible results in Chinese neonates. The normal range of ear temperature for Chinese neonates is 35 degrees C to 37 degrees C. Ear temperature > 37.8 degrees C should be regarded as fever.
Apparatus for accurately measuring high temperatures
Smith, D.D.
The present invention is a thermometer used for measuring furnace temperatures in the range of about 1800/sup 0/ to 2700/sup 0/C. The thermometer comprises a broadband multicolor thermal radiation sensor positioned to be in optical alignment with the end of a blackbody sight tube extending into the furnace. A valve-shutter arrangement is positioned between the radiation sensor and the sight tube and a chamber for containing a charge of high pressure gas is positioned between the valve-shutter arrangement and the radiation sensor. A momentary opening of the valve shutter arrangement allows a pulse of the high gas to purge the sight tube of air-borne thermal radiation contaminants which permits the radiation sensor to accurately measure the thermal radiation emanating from the end of the sight tube.
Apparatus for accurately measuring high temperatures
Smith, Douglas D.
1985-01-01
The present invention is a thermometer used for measuring furnace temperaes in the range of about 1800.degree. to 2700.degree. C. The thermometer comprises a broadband multicolor thermal radiation sensor positioned to be in optical alignment with the end of a blackbody sight tube extending into the furnace. A valve-shutter arrangement is positioned between the radiation sensor and the sight tube and a chamber for containing a charge of high pressure gas is positioned between the valve-shutter arrangement and the radiation sensor. A momentary opening of the valve shutter arrangement allows a pulse of the high gas to purge the sight tube of air-borne thermal radiation contaminants which permits the radiation sensor to accurately measure the thermal radiation emanating from the end of the sight tube.
Picowatt Resolution Calorimetry for Micro and Nanoscale Energy Transport Studies
NASA Astrophysics Data System (ADS)
Sadat, Seid H.
Precise quantification of energy transport is key to obtaining insights into a wide range of phenomena across various disciplines including physics, chemistry, biology and engineering. This thesis describes technical advancements into heat-flow calorimetry which enable measurement of energy transport at micro and nanoscales with picowatt resolution. I have developed two types of microfabricated calorimeter devices and demonstrated single digit picowatt resolution at room temperature. Both devices incorporate two distinct features; an active area isolated by a thermal conductance (GTh) of less than 1 microW/K and a high resolution thermometer with temperature resolution (DeltaTres) in the micro kelvin regime. These features enable measurements of heat currents (q) with picowatt resolution (q= Th xDeltaTres). In the first device the active area is suspended via silicon nitride beams with excellent thermal isolation (~600 nW/K) and a bimaterial cantilever (BMC) thermometer with temperature resolution of ~6 microK. Taken together this design enabled calorimetric measurements with 4 pW resolution. In the second device, the BMC thermometry technique is replaced by a high-resolution resistance thermometry scheme. A detailed noise analysis of resistance thermometers, confirmed by experimental data, enabled me to correctly predict the resolution of different measurement schemes and propose techniques to achieve an order of magnitude improvement in the resolution of resistive thermometers. By incorporating resistance thermometers with temperature resolution of ~30 microK, combined with a thermal isolation of ~150 nW/K, I demonstrated an all-electrical calorimeter device with a resolution of ~ 5 pW. Finally, I used these calorimeters to study Near-Field Radiative Heat Transfer (NF-RHT). Using these devices, we studied--for the first time--the effect of film thickness on the NF-RHT between two dielectric surfaces. We showed that even a very thin film (~50 nm) of silicon dioxide deposited on a gold surface dramatically enhances NF-RHT between the coated surface and a second silica surface. Specifically, we find that the resulting heat fluxes are very similar to those between two bulk silicon dioxide surfaces when the gap size is reduced to be comparable to that of the film thickness. This interesting effect is understood on the basis of detailed computational analysis, which shows that the NF-RHT in gaps comparable to film thickness is completely dominated by the contributions from surface phonon-polaritons whose effective skin depth is comparable to the film thickness. These results are expected to hold true for various dielectric surfaces where heat transport is dominated by surface phonon-polaritons and have important implications for near-field based thermo photovoltaic devices and for near-field based thermal management.
... dehydration, such as a dry mouth, decreased or dark urine, or refusal to drink fluids Skin rashes ... phased out and are no longer recommended. No matter which type of thermometer you use, take these ...
... Your Health Possible Health Effects Contamination and Exposure Acute Radiation Syndrome (ARS) Cutaneous Radiation Injury (CRI) Cancer and Long- ... Information for Professionals Radiation Thermometer Information for ... Radiation Syndrome: A Fact Sheet for Clinicians Cutaneous Radiation Injury ( ...
... Your Health Possible Health Effects Contamination and Exposure Acute Radiation Syndrome (ARS) Cutaneous Radiation Injury (CRI) Cancer and Long- ... Information for Professionals Radiation Thermometer Information for ... Radiation Syndrome: A Fact Sheet for Clinicians Cutaneous Radiation Injury ( ...
46 CFR 160.151-45 - Equipment required for servicing facilities.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., or other pressure-measurement device or pressure gauge of equivalent accuracy and sensitivity; (j) Thermometer; (k) Barometer, aneroid or mercury; (l) Calibrated torque-wrench for assembling the inflation...
46 CFR 160.151-45 - Equipment required for servicing facilities.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., or other pressure-measurement device or pressure gauge of equivalent accuracy and sensitivity; (j) Thermometer; (k) Barometer, aneroid or mercury; (l) Calibrated torque-wrench for assembling the inflation...
Kreissl, Hannah; Neiger, Reto
2015-01-01
To assess the accuracy of obtaining body temperatures in dogs with a noncontact infrared thermometer (NCIT) on the cornea compared with a rectal digital thermometer (RDT). Prospective single center study. University teaching hospital. Three hundred dogs presented with low, normal, or high body temperatures. Three body temperature readings were measured by an RDT and by an NCIT on the cornea of the left eye by 2 investigators (experienced and inexperienced). Results obtained by the 2 methods were compared. Median body temperature measured by the experienced investigator with the RDT and the NCIT were 38.3°C (range 35.5°C-41.1°C; 95% CI: 38.2-38.4°C) and 37.7°C (35.9°C-40.1°C; 95% CI: 37.7°C-37.9°C), respectively. Measurement of RDT as well as of NCIT correlated well between both investigators (rRDT = 0.94; rNCIT = 0.82; respectively, P < 0.001 for both methods). Mean RDT and NCIT-temperature correlated poorly (r = 0.43; P < 0.001) when taken by the experienced investigator and even less by the nonexperienced investigator (r = 0.38; P < 0.001). Repeatability of the NCIT revealed an unsatisfactory value (0.24°C) compared to RDT measurement (0.12°C). Agreement between both devices in measuring low, normal, and high values, calculated by Cohens-Kappa, was unsatisfactory (к = 0.201; P < 0.001). Calculating the receiver operating characteristic curve to determine the best threshold for fever (defined as RDT temperature >39.0°C) showed an area under the curve of 0.76. Mean discomfort score was significantly lower using NCIT compared to RDT measurement (P < 0.001). There was poor agreement between body temperatures obtained by RDT and NCIT. The corneal NCIT measurement tends to underrecognize hypothermic and hyperthermic conditions. Although the use of the NCIT yields faster results and is significantly more comfortable for the dog than the RDT measurement, it cannot be recommended in dogs at this time. © Veterinary Emergency and Critical Care Society 2015.
The Kelvin and Temperature Measurements
Mangum, B. W.; Furukawa, G. T.; Kreider, K. G.; Meyer, C. W.; Ripple, D. C.; Strouse, G. F.; Tew, W. L.; Moldover, M. R.; Johnson, B. Carol; Yoon, H. W.; Gibson, C. E.; Saunders, R. D.
2001-01-01
The International Temperature Scale of 1990 (ITS-90) is defined from 0.65 K upwards to the highest temperature measurable by spectral radiation thermometry, the radiation thermometry being based on the Planck radiation law. When it was developed, the ITS-90 represented thermodynamic temperatures as closely as possible. Part I of this paper describes the realization of contact thermometry up to 1234.93 K, the temperature range in which the ITS-90 is defined in terms of calibration of thermometers at 15 fixed points and vapor pressure/temperature relations which are phase equilibrium states of pure substances. The realization is accomplished by using fixed-point devices, containing samples of the highest available purity, and suitable temperature-controlled environments. All components are constructed to achieve the defining equilibrium states of the samples for the calibration of thermometers. The high quality of the temperature realization and measurements is well documented. Various research efforts are described, including research to improve the uncertainty in thermodynamic temperatures by measuring the velocity of sound in gas up to 800 K, research in applying noise thermometry techniques, and research on thermocouples. Thermometer calibration services and high-purity samples and devices suitable for “on-site” thermometer calibration that are available to the thermometry community are described. Part II of the paper describes the realization of temperature above 1234.93 K for which the ITS-90 is defined in terms of the calibration of spectroradiometers using reference blackbody sources that are at the temperature of the equilibrium liquid-solid phase transition of pure silver, gold, or copper. The realization of temperature from absolute spectral or total radiometry over the temperature range from about 60 K to 3000 K is also described. The dissemination of the temperature scale using radiation thermometry from NIST to the customer is achieved by calibration of blackbody sources, tungsten-strip lamps, and pyrometers. As an example of the research efforts in absolute radiometry, which impacts the NIST spectral irradiance and radiance scales, results with filter radiometers and a high-temperature blackbody are summarized. PMID:27500019
Temporal artery thermometry in children younger than 5 years: a comparison with rectal thermometry.
Odinaka, Kelechi K; Edelu, Benedict O; Nwolisa, Charles E; Amamilo, Ifeyinwa B; Okolo, Seline N
2014-12-01
Temporal artery (TA) thermometry has come as one of the new methods for temperature measurement, especially in children in whom accurate temperature monitoring can save lives. The device which is convenient and simple to use is yet to gain popularity in several parts of the world, as there are conflicting reports of its accuracy. This study compares the accuracy of the TA thermometry in children younger than 5 years using the rectal thermometry as the gold standard. Temperature was measured simultaneously in eligible children younger than 5 years from the forehead and rectum using the TA thermometer (TAT-2000C Exergen, USA) and standard mercury in glass rectal thermometer, respectively. The difference between the mean temperatures obtained by the 2 thermometry methods was tested using the paired t test. Pearson correlation coefficient, linear regression, and Bland-Altman plot were also used to test the relationship and agreement between the 2 instruments. The sensitivity, specificity, and positive and negative predictive values were also calculated. Overall, the mean TA temperature (37.80°C ± 1.07°C) was significantly lower than the mean rectal temperature (38.07°C ± 0.95°C), P < 0.001. In neonates, however, the mean difference was not significant, 0.02 ± 0.59 (P = 0.810). There was a significant positive correlation between the rectal and the temporal temperatures (r = 0.80, P < 0.01). The Bland-Altman plot showed wide variation in the limit of agreement between the rectal and the TA temperatures which ranged from -1.02°C to +1.56°C. The sensitivity of the TA thermometer was 64.6% and 83.5%, respectively, at a TA fever cutoff of 38.0°C and 37.7°C. Temporal artery thermometer is not accurate enough for the measurement of core body temperature in children younger than 5 years. However, it may be used as a tool for screening for fever in very busy clinics and emergency room at a fever cutoff of 37.7°C.
An evaluation of a zero-heat-flux cutaneous thermometer in cardiac surgical patients.
Eshraghi, Yashar; Nasr, Vivian; Parra-Sanchez, Ivan; Van Duren, Albert; Botham, Mark; Santoscoy, Thomas; Sessler, Daniel I
2014-09-01
Although core temperature can be measured invasively, there are currently no widely available, reliable, noninvasive thermometers for its measurement. We thus compared a prototype zero-heat-flux thermometer with simultaneous measurements from a pulmonary artery catheter. Specifically, we tested the hypothesis that zero-heat-flux temperatures are sufficiently accurate for routine clinical use. Core temperature was measured from the thermistor of a standard pulmonary artery catheter and with a prototype zero-heat-flux deep-tissue thermometer in 105 patients having nonemergent cardiac surgery. Zero-heat-flux probes were positioned on the lateral forehead and lateral neck. Skin surface temperature probes were attached to the forehead just adjacent to the zero-heat-flux probe. Temperatures were recorded at 1-minute intervals, excluding the period of cardiopulmonary bypass, and for the first 4 postoperative hours. Zero-heat-flux and pulmonary artery temperatures were compared with bias analysis; differences exceeding 0.5°C were considered to be potentially clinically important. The mean duration in the operating room was 279 ± 75 minutes, and the mean cross-clamp time was 118 ± 50 minutes. All subjects were monitored for an additional 4 hours in the intensive care unit. The average overall difference between forehead zero-heat-flux and pulmonary artery temperatures (i.e., forehead minus pulmonary artery) was -0.23°C (95% limits of agreement of ±0.82); 78% of the differences were ≤0.5°C. The average intraoperative temperature difference was -0.08°C (95% limits of agreement of ±0.88); 84% of the differences were ≤0.5°C. The average postoperative difference was -0.32°C (95% limits of agreement of ±0.75); 84% of the differences were ≤0.5°C. Bias and precision values for neck site were similar to the forehead values. Uncorrected forehead skin temperature showed an increasing negative bias as core temperature decreased. Core temperature can be noninvasively measured using the zero-heat-flux method. Bias was small, but precision was slightly worse than our designated 0.5°C limits compared with measurements from a pulmonary artery catheter.
NASA Astrophysics Data System (ADS)
Mesa, J.; Lange, R. A.; Pu, X.
2017-12-01
Nepheline-normative, high-Mg basalts erupted from the western Mexican arc, along the Tepic-Zacoalco rift (TZR), have a trace-element signature consistent with an asthenosphere source, whereas calc-alkaline basalts erupted from the central Mexican arc in the Michoacan-Guanajuato volcanic field (MGVF) have a trace-element signature consistent with a mantle source strongly affected by subduction fluids. In this study, olivine-melt thermometry and plagioclase-liquid hygrometry are used to constrain the temperature and melt water content of the alkaline TZR basalts. The presence of diffusion-limited growth textures in olivine and plagioclase phenocrysts provide preliminary evidence of rapid growth during ascent. For each basalt sample, a histogram of all analyzed olivines in each sample allows the most Fo-rich composition to be identified, which matches the calculated composition at the liquidus via MELTS (Ghiorso & Sack, 1995; Asimow & Ghiorso, 1998) at fO2 values of QFM +2. Therefore a newly developed olivine-melt thermometer, based on DNiol/liq (Pu et al., 2017) was used to calculate temperature at the onset of olivine crystallization during ascent. Temperatures range from 1076-1247°C, whereas those calculated using an olivine-melt thermometer based on DMgol/liq range from 1141-1236 °C. Olivine-melt thermometers based on DMgol/liq are sensitive to melt H2O content, therefore ΔT = TMg - TNi (≤ 82 degrees) may be used as a qualitative indicator of melt H2O (≤ 2.6 wt% H2O; Pu et al., 2017). When temperatures from the Ni-thermometer are applied to the most calcic plagioclase in each sample (Waters & Lange, 2015), calculated melt H2O contents range from 1.3-1.9 (± 0.4) wt%. These values are significantly lower than those obtained from high-Mg calc-alkaline basalts from the MGVF using similar methods (1.9-5.0 wt%; Pu et al., 2017), consistent with a reduced involvement of slab-derived fluids in the origin of the alkaline TZR basalts from western Mexico.
ERIC Educational Resources Information Center
Zimmerman, Marianna
1975-01-01
Describes a classroom activity which involved sixth grade students in a learning situation including making ice cream, safety procedures in a science laboratory, calibrating a thermometer, using metric units of volume and mass. (EB)
DTPA (Diethylenetriamine pentaacetate)
... Your Health Possible Health Effects Contamination and Exposure Acute Radiation Syndrome (ARS) Cutaneous Radiation Injury (CRI) Cancer and Long- ... Information for Professionals Radiation Thermometer Information for ... Radiation Syndrome: A Fact Sheet for Clinicians Cutaneous Radiation Injury ( ...
... Your Health Possible Health Effects Contamination and Exposure Acute Radiation Syndrome (ARS) Cutaneous Radiation Injury (CRI) Cancer and Long- ... Information for Professionals Radiation Thermometer Information for ... Radiation Syndrome: A Fact Sheet for Clinicians Cutaneous Radiation Injury ( ...
... Your Health Possible Health Effects Contamination and Exposure Acute Radiation Syndrome (ARS) Cutaneous Radiation Injury (CRI) Cancer and Long- ... Information for Professionals Radiation Thermometer Information for ... Radiation Syndrome: A Fact Sheet for Clinicians Cutaneous Radiation Injury ( ...
27 CFR 30.32 - Determination of proof obscuration.
Code of Federal Regulations, 2010 CFR
2010-04-01
... added to the temperature corrected hydrometer reading will give the true proof. (c) Distillation method... use of a precision hydrometer and thermometer in accordance with the provisions of § 13.23 to the...
49 CFR 179.201-8 - Sampling device and thermometer well.
Code of Federal Regulations, 2014 CFR
2014-10-01
... HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW and 115AW) § 179.201-8 Sampling...
49 CFR 179.201-8 - Sampling device and thermometer well.
Code of Federal Regulations, 2013 CFR
2013-10-01
... HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW and 115AW) § 179.201-8 Sampling...
49 CFR 179.201-8 - Sampling device and thermometer well.
Code of Federal Regulations, 2012 CFR
2012-10-01
... HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW and 115AW) § 179.201-8 Sampling...
49 CFR 179.201-8 - Sampling device and thermometer well.
Code of Federal Regulations, 2010 CFR
2010-10-01
... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS SPECIFICATIONS FOR TANK CARS Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW and 115AW) § 179.201-8...
Keep Listeria Out of Your Kitchen
... in the refrigerator. Make certain foods do not leak juices onto other foods. Place an appliance thermometer, ... walls and shelves of your refrigerator with warm water and liquid soap, then rinse. As an added ...
ERIC Educational Resources Information Center
School Science Review, 1977
1977-01-01
Includes methods for demonstrating Schlieren effect, measuring refractive index, measuring acceleration, presenting concepts of optics, automatically recording weather, constructing apparaturs for sound experiments, using thermistor thermometers, using the 741 operational amplifier in analog computing, measuring inductance, electronically ringing…
ERIC Educational Resources Information Center
School Science Review, 1981
1981-01-01
Describes 13 activities, experiments and demonstrations, including the preparation of iron (III) chloride, simple alpha-helix model, investigating camping gas, redox reactions of some organic compounds, a liquid crystal thermometer, and the oxidation number concept in organic chemistry. (JN)
7 CFR 70.15 - Equipment and facilities for graders.
Code of Federal Regulations, 2011 CFR
2011-01-01
... drill holes in frozen product for inserting the metal thermometer stem to determine temperature. (3... or less for weighing bulk containers of poultry and test weights for such scales. (b) Furnished...
Application of vaginal temperature measurement in bitches.
Maeder, B; Arlt, S; Burfeind, O; Heuwieser, W
2012-12-01
Finding innovative, non-invasive methods for continuously measuring body temperature minimizing human interference is important for accurate data collection. The objective of this study was to assess feasibility and accuracy of continuous body temperature measurements with loggers placed in the vaginal cavity of bitches. First, an in vitro experiment was performed to compare values obtained by temperature loggers (n = 26) to a calibrated liquid-in-glass thermometer. The mean differences between the two methods were low. Next, an in vivo experiment was performed using five healthy bitches, and values obtained by the vaginal loggers were compared to measurements collected rectally with digital thermometers. The results show that rectal and vaginal temperatures were correlated. The mean differences between rectal and vaginal temperatures were negligible. We conclude that the utilized temperature loggers provide accurate and reliable data. © 2012 Blackwell Verlag GmbH.
Performance of Magnetic Penetration Thermometers for X-Ray Astronomy
NASA Technical Reports Server (NTRS)
Nagler, P. C.; Adams, J. S.; Balvin, M. A.; Bandler, S. R.; Denis, K. L.; Hsieh, W. T.; Kelly, D. P.; Porst, J. P.; Sadleir, J. E.; Seidel, G. M.;
2012-01-01
The ideal X-ray camera for astrophysics would have more than a million pixels and provide an energy resolution of better than leV FWHM for energies up to 10 keY. We have microfabricated and characterized thin-film magnetic penetration thermometers (MPTs) that show great promise towards meeting these capabilities. MPTs operate in similar fashion to metallic magnetic calorimeters (MMCs), except that a superconducting sensor takes the place of a paramagnetic sensor and it is the temperature dependence of the superconductor's diamagnetic response that provides the temperature sensitivity. We present a description of the design and performance of our prototype thin-film MPTs with MoAu bilayer sensors, which have demonstrated an energy resolution of approx 2 eV FWHM at 1.5 keY and 4.3 eV FWHM at 5.9 keY.
Sonic Thermometer for High-Altitude Balloons
NASA Technical Reports Server (NTRS)
Bognar, John
2012-01-01
The sonic thermometer is a specialized application of well-known sonic anemometer technology. Adaptations have been made to the circuit, including the addition of supporting sensors, which enable its use in the high-altitude environment and in non-air gas mixtures. There is a need to measure gas temperatures inside and outside of superpressure balloons that are flown at high altitudes. These measurements will allow the performance of the balloon to be modeled more accurately, leading to better flight performance. Small thermistors (solid-state temperature sensors) have been used for this general purpose, and for temperature measurements on radiosondes. A disadvantage to thermistors and other physical (as distinct from sonic) temperature sensors is that they are subject to solar heating errors when they are exposed to the Sun, and this leads to issues with their use in a very high-altitude environment
Bloch-Nordsieck thermometers: one-loop exponentiation in finite temperature QED
NASA Astrophysics Data System (ADS)
Gupta, Sourendu; Indumathi, D.; Mathews, Prakash; Ravindran, V.
1996-02-01
We study the scattering of hard external particles in a heat bath in a real-time formalism for finite temperature QED. We investigate the distribution of the 4-momentum difference of initial and final hard particles in a fully covariant manner when the scale of the process, Q, is much larger than the temperature, T. Our computations are valid for all T subject to this constraint. We exponentiate the leading infra-red term at one-loop order through a resummation of soft (thermal) photon emissions and absorptions. For T > 0, we find that tensor structures arise which are not present at T = 0. These cant' thermal signatures. As a result, external particles can serve as thermometers introduced into the heat bath. We investigate the phase space origin of log( Q/ m) and log ( Q/ T) teens.
Single fiber temperature probe configuration using anti-Stokes luminescence from Cr:GdAlO3
NASA Astrophysics Data System (ADS)
Eldridge, Jeffrey I.
2018-06-01
Single-photon excitation of anti-Stokes-shifted emission from a thermographic phosphor allows operation of a luminescence decay-based single fiber temperature probe with negligible interference from background fiber-generated Raman scattering. While single fiber probe configurations for luminescence-based fiber optic thermometers offer advantages of simple design, compactness, and superior emission light collection efficiency, their effective use has been limited by interference from Raman scattering in the fiber probe and excitation delivery fiber that produces distortion of the luminescence decay that follows the excitation pulse. The near elimination of interference by background fiber-generated Raman scattering was demonstrated by incorporating a Cr-doped GdAlO3 (Cr:GdAlO3) thermographic phosphor as the sensing element at the end of a single fiber luminescence decay-based thermometer and detecting anti-Stokes-shifted luminescence centered at 542 or 593 nm produced by 695 nm excitation. Measurements were performed using both silica (up to 1150 °C) and single-crystal YAG (up to 1200 °C) fiber-based thermometers. Selection of emission detection centered at 542 nm greatly benefited the YAG fiber probe measurements by practically eliminating detection of otherwise significant luminescence from Cr3+ impurities in the YAG fiber. For both the silica and YAG fiber probes, the relative benefit of adopting single-photon excitation of anti-Stokes-shifted luminescence was evaluated by comparison with results obtained by conventional 532 nm excitation of Stokes-shifted luminescence.
Ferromagnetic-Insulator-Based Superconducting Junctions as Sensitive Electron Thermometers
NASA Astrophysics Data System (ADS)
Giazotto, F.; Solinas, P.; Braggio, A.; Bergeret, F. S.
2015-10-01
We present an exhaustive theoretical analysis of charge and thermoelectric transport in a normal-metal-ferromagnetic-insulator-superconductor junction and explore the possibility of its use as a sensitive thermometer. We investigate the transfer functions and the intrinsic noise performance for different measurement configurations. A common feature of all configurations is that the best temperature-noise performance is obtained in the nonlinear temperature regime for a structure based on an Europium chalcogenide ferromagnetic insulator in contact with a superconducting Al film structure. For an open-circuit configuration, although the maximal intrinsic temperature sensitivity can achieve 10 nK Hz-1 /2 , a realistic amplifying chain will reduce the sensitivity up to 10 μ K Hz-1 /2 . To overcome this limitation, we propose a measurement scheme in a closed-circuit configuration based on state-of-the-art superconducting-quantum-interference-device detection technology in an inductive setup. In such a case, we show that temperature-noise can be as low as 35 nK Hz-1 /2 . We also discuss a temperature-to-frequency converter where the obtained thermovoltage developed over a Josephson junction operated in the dissipative regime is converted into a high-frequency signal. We predict that the structure can generate frequencies up to approximately 120 GHz and transfer functions up to 200 GHz /K at around 1 K. If operated as an electron thermometer, the device may provide temperature-noise lower than 35 nK Hz-1 /2 thereby being potentially attractive for radiation-sensing applications.
Thermodynamic Temperature Measurement to the Indium Point Based on Radiance Comparison
NASA Astrophysics Data System (ADS)
Yamaguchi, Y.; Yamada, Y.
2017-04-01
A multi-national project (the EMRP InK project) was completed recently, which successfully determined the thermodynamic temperatures of several of the high-temperature fixed points above the copper point. The National Metrology Institute of Japan contributed to this project with its newly established absolute spectral radiance calibration capability. In the current study, we have extended the range of thermodynamic temperature measurement to below the copper point and measured the thermodynamic temperatures of the indium point (T_{90} = 429.748 5 K), tin point (505.078 K), zinc point (692.677 K), aluminum point (933.473 K) and the silver point (1 234.93 K) by radiance comparison against the copper point, with a set of radiation thermometers having center wavelengths ranging from 0.65 μm to 1.6 μm. The copper-point temperature was measured by the absolute radiation thermometer which was calibrated by radiance method traceable to the electrical substitution cryogenic radiometer. The radiance of the fixed-point blackbodies was measured by standard radiation thermometers whose spectral responsivity and nonlinearity are precisely evaluated, and then the thermodynamic temperatures were determined from radiance ratios to the copper point. The values of T-T_{90} for the silver-, aluminum-, zinc-, tin- and indium-point cells were determined as -4 mK (U = 104 mK, k=2), -99 mK (88 mK), -76 mK (76 mK), -68 mK (163 mK) and -42 mK (279 mK), respectively.
[Factitious fevers as a cause of prolonged fevers. Apropos of 5 clinical cases].
Potin, M; Regamey, C; Glauser, M P
1983-10-22
Among the numerous causes of prolonged fever of unknown origin, the factitious fevers are frequently considered last after much diagnostic and therapeutic effort. Five observations of factitious fever are presented including 2 cases of thermometer manipulation in men aged 45 and 80. The latter patient is the oldest in whom such a case has been reported. In the first case the prolonged fever led to exploratory laparotomy with splenectomy followed by antilymphoma chemotherapy before the thermometer manipulation was discovered. This patient had previously been treated successfully for stage Ib Hodgkin lymphoma. In the other case hospitalization had lasted several weeks, and much antibiotic and steroid treatment had been administered, before the manipulation was suspected. A third case of thermometer manipulation was observed in a 57-year-old woman who had been presenting with factitious symptoms for over 10 years. Two other cases of factitious fever due to self-induced infections have been observed in two young women aged 23 and 27, both in paramedical professions. These self-induced infections led to polymicrobial bacteremia, exploratory laparotomy and hemicolectomy in one case, and to probable bacterial meningitis in the other. Certain aspects of these cases agree well with the diagnostic criteria of factitious fever described in the literature. We feel it is important to recognize this cause of febrile states, even if there is an apparent etiology, in order to avoid much vain investigation and prolonged hospitalization.
Jara, Amanda L; Hanson, Jarod M; Gabbard, Jon D; Johnson, Scott K; Register, Emery T; He, Biao
2016-01-01
During disease outbreaks, core temperature is a useful health metric in swine, due to the presence of pyrexia especially during the acute phase of infection. Despite technologic advances in other facets of swine production and health management, rectal thermometry continues to be the ‘gold standard’ for measuring core body temperature. However, for various reasons, collecting rectal temperatures can be difficult and unsafe depending on the housing modality. In addition, the delay between insertion of the rectal thermometer and obtaining a reading can affect measurement accuracy, especially when the pig requires physical restraint. Clearly safer, faster, and more accurate and precise temperature acquisition methods that necessitate minimal or no handling of swine are needed. We therefore compared rectal thermometers, subcutaneous microchips, and an inexpensive handheld infrared thermometer by measuring the core body temperature of 24 male castrated piglets at random intervals over a 5-wk period. The core body temperature (mean ± 1 SD) was 39.3 ± 0.5 °C by rectal thermometry, 39.0 ± 0.7 °C by microchip transponder, and 34.3 ± 1.0 °C by infrared thermometry; these 3 values differed significantly. Although the readings obtain by using infrared thermometry were numerically lower than those from the other methods, it is arguably the safest method for assessing the core temperature of swine and showed strong relative correlation with rectal temperature. PMID:27657715
Sensitivity of blackbody effective emissivity to wavelength and temperature: By genetic algorithm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ejigu, E. K.; Liedberg, H. G.
A variable-temperature blackbody (VTBB) is used to calibrate an infrared radiation thermometer (pyrometer). The effective emissivity (ε{sub eff}) of a VTBB is dependent on temperature and wavelength other than the geometry of the VTBB. In the calibration process the effective emissivity is often assumed to be constant within the wavelength and temperature range. There are practical situations where the sensitivity of the effective emissivity needs to be known and correction has to be applied. We present a method using a genetic algorithm to investigate the sensitivity of the effective emissivity to wavelength and temperature variation. Two matlab® programs are generated:more » the first to model the radiance temperature calculation and the second to connect the model to the genetic algorithm optimization toolbox. The effective emissivity parameter is taken as a chromosome and optimized at each wavelength and temperature point. The difference between the contact temperature (reading from a platinum resistance thermometer or liquid in glass thermometer) and radiance temperature (calculated from the ε{sub eff} values) is used as an objective function where merit values are calculated and best fit ε{sub eff} values selected. The best fit ε{sub eff} values obtained as a solution show how sensitive they are to temperature and wavelength parameter variation. Uncertainty components that arise from wavelength and temperature variation are determined based on the sensitivity analysis. Numerical examples are considered for illustration.« less
27 CFR 30.31 - Determination of proof.
Code of Federal Regulations, 2010 CFR
2010-04-01
... milligrams of solids per 100 milliliters of spirits shall be determined by the use of a hydrometer and...) By the use of a hydrometer and a thermometer after the spirits have been distilled in a small...
Simple device measures solar radiation
NASA Technical Reports Server (NTRS)
Humphries, W. R.
1977-01-01
Simple inexpensive thermometer, insolated from surroundings by transparent glass or plastic encasement, measures intensities of solar radiation, or radiation from other sources such as furnaces or ovens. Unit can be further modified to accomplish readings from remote locations.
Datalogging the Distillation Process.
ERIC Educational Resources Information Center
Soares, Allan; Creevy, Steven
1995-01-01
Presents a distillation experiment that uses temperature sensors connected to a computer in place of thermometers, and enables the whole class to view the data on a monitor and interpret and discuss the data in real time. (JRH)
ERIC Educational Resources Information Center
School Science Review, 1982
1982-01-01
Outlines methodology, demonstrations, and materials including: an inexpensive wave machine; speed of sound in carbon dioxide; diffraction grating method for measuring spectral line wavelength; linear electronic thermometer; analogy for bromine diffusion; direct reading refractice index meter; inexpensive integrated circuit spectrophotometer; and…
High-Temperature Thermometer Using Cr-Doped GdAlO3 Broadband Luminescence
NASA Technical Reports Server (NTRS)
Eldridge, Jeffrey; Chambers, Matthew
2011-01-01
A new concept has been developed for a high-temperature luminescence-based optical thermometer that both shows the desired temperature sensitivity in the upper temperature range of present state-of-the-art luminescence thermometers (above 1,300 C), while maintaining substantial stronger luminescence signal intensity that will allow these optical thermometers to operate in the presence of the high thermal background radiation typical of industrial applications. This objective is attained by using a Cr-doped GdAlO3 (Cr:GdAlO3) sensor with an orthorhombic perovskite structure, resulting in broadband luminescence that remains strong at high temperature due to the favorable electron energy level spacing of Cr:GdAlO3. The Cr:GdAlO3 temperature (and pressure) sensor can be incorporated into, or applied onto, a component s surface when a non-contact surface temperature measurement is desired, or alternatively, the temperature sensor can be attached to the end of a fiber-optic probe that can then be positioned at the location where the temperature measurement is desired. In the case of the fiber-optic probe, both the pulsed excitation and the luminescence emission travel through the fiber-optic light guide. In either case, a pulsed light source provides excitation of the luminescence, and the broadband luminescence emission is collected. Real-time temperature measurements are obtain ed using a least-squares fitting algorithm that determines the luminescence decay time, which has a known temperature dependence established by calibration. Due to the broad absorption and emission bands for Cr:GdAlO3, there is considerable flexibility in the choice of excitation wavelength and emission wavelength detection bands. The strategic choice of the GdAlO3 host is based on its high crystal field, phase stability, and distorted symmetry at the Cr3+ occupation sites. The use of the broadband emission for temperature sensing at high temperatures is a key feature of the invention and is novel since broadband luminescence emission normally shows severe thermal quenching. The tightly bound AlO6 octahedra in GdAlO3 results in a larger energy barrier to nonradiative decays than in other materials and therefore makes using broadband emission for temperature sensing possible at high temperatures. This approach results in a substantial increase in temperature capability. For example, the most commonly used Cr-doped crystal used for luminescence-based temperature measurements, ruby, has only been demonstrated up to 600 C, whereas the Cr:GdAlO3 optical thermometer under development has already been shown to exhibit useful luminescence up to 1,300 C. Because GdAlO3 is non-reactive and is stable in harsh, high-temperature environments, sensors composed of Cr:GdAlO3 will be very well suited for remote high-temperature measurements in engine or industrial environments where its intense high-temperature luminescence will stand out above significant thermal radiation background levels.
16 CFR 1500.43a - Method of test for flashpoint of volatile flammable materials.
Code of Federal Regulations, 2012 CFR
2012-01-01
... between the temperature control dial and the thermometer readings at each major (numbered) dial division... block of suitable conductivity with a cylindrical depression, or sample cup, over which is fitted a...
16 CFR 1500.43a - Method of test for flashpoint of volatile flammable materials.
Code of Federal Regulations, 2011 CFR
2011-01-01
... between the temperature control dial and the thermometer readings at each major (numbered) dial division... block of suitable conductivity with a cylindrical depression, or sample cup, over which is fitted a...
16 CFR 1500.43a - Method of test for flashpoint of volatile flammable materials.
Code of Federal Regulations, 2014 CFR
2014-01-01
... between the temperature control dial and the thermometer readings at each major (numbered) dial division... block of suitable conductivity with a cylindrical depression, or sample cup, over which is fitted a...
A Direct Reading Thermometer Based on a Silicon Diode.
ERIC Educational Resources Information Center
Kirkup, L.; Tonthat, C.
1998-01-01
Describes a simple circuit based on an inexpensive quad operational amplifier that permits a direct-reading temperature instrument to be constructed using silicon diodes. Encourages the use of this equipment in introductory thermal experiments. (DDR)
Theoretical Odds and Practical Ends
ERIC Educational Resources Information Center
Siddons, J. C.
1974-01-01
Describes a variety of experiments and activities such as refractive index by an interference method, Young's third slit, a microscope problem, uses of a hand stroboscope, an acceleration game, an aluminum thermometer, why milk boils over, and others. (BR)
ERIC Educational Resources Information Center
School Science Review, 1983
1983-01-01
Provided are reviews of science equipment/apparatus. Items reviewed include: Harris Micro-ecology tubes; Harris chromosome investigation kit; Harris trycult slides; a pressure cooker with thermometer; digital pH meter; digital scaler timer; electrical compensation calorimeter; and Mains alternating current ammeter. (JN)
Pregnancy - identifying fertile days
... mean ovulation is near. TAKING YOUR BASAL BODY TEMPERATURE After you ovulate, your body temperature will rise and stay at a higher level ... can use a special thermometer to take your temperature in the morning before you get out of ...
4 Basic Steps to Food Safety at Home
... F -Ground Beef, Pork, Lamb 160 °F -Turkey, Chicken, Duck 165 °F • Use a food thermometer to ... cause you to feel like you have the flu. Food illness can also cause serious health problems, ...
ERIC Educational Resources Information Center
Shaw, G. W.; And Others
1989-01-01
Provides a reading list for A- and S-level biology. Contains several experiments and demonstrations with topics on: the intestine, bullock corneal cells, valences, the science of tea, automated hydrolysis, electronics characteristics, bromine diffusion, enthalpy of vaporization determination, thermometers, pendulums, hovercraft, Bernoulli fluid…
Evaluation of thermal overload in boiler operators.
Braga, Camila Soares; Rodrigues, Valéria Antônia Justino; Campos, Julio César Costa; de Souza, Amaury Paulo; Minette, Luciano José; de Moraes, Angêlo Casali; Sensato, Guilherme Luciano
2012-01-01
The Brazilians educational institutions need a large energy demand for the operation of laundries, restaurants and accommodation of students. Much of that energy comes from steam generated in boilers with wood fuel. The laboral activity in boiler may present problems for the operator's health due to exposure to excessive heat, and its operation has a high degree of risk. This paper describes an analysis made the conditions of thermal environment in the operation of a B category boiler, located at a Higher Education Institution, located in the Zona da Mata Mineira The equipments used to collect data were Meter WBGT of the Heat Index; Meter of Wet Bulb Index and Globe Thermometer (WBGT); Politeste Instruments, an anemometer and an Infrared Thermometer. By the application of questionnaires, the second phase consisted of collecting data on environmental factors (temperature natural environment, globe temperature, relative humidity and air velocity). The study concluded that during the period evaluated, the activity had thermal overload.
Reliability and validity of electrothermometers and associated thermocouples.
Jutte, Lisa S; Knight, Kenneth L; Long, Blaine C
2008-02-01
Examine thermocouple model uncertainty (reliability+validity). First, a 3x3 repeated measures design with independent variables electrothermometers and thermocouple model. Second, a 1x3 repeated measures design with independent variable subprobe. Three electrothermometers, 3 thermocouple models, a multi-sensor probe and a mercury thermometer measured a stable water bath. Temperature and absolute temperature differences between thermocouples and a mercury thermometer. Thermocouple uncertainty was greater than manufactures'claims. For all thermocouple models, validity and reliability were better in the Iso-Themex than the Datalogger, but there were no practical differences between models within an electrothermometers. Validity of multi-sensor probes and thermocouples within a probe were not different but were greater than manufacturers'claims. Reliability of multiprobes and thermocouples within a probe were within manufacturers claims. Thermocouple models vary in reliability and validity. Scientists should test and report the uncertainty of their equipment rather than depending on manufactures' claims.
Thermometry of Silicon Nanoparticles
NASA Astrophysics Data System (ADS)
Mecklenburg, Matthew; Zutter, Brian; Regan, B. C.
2018-01-01
Current thermometry techniques lack the spatial resolution required to see the temperature gradients in typical, highly scaled modern transistors. As a step toward addressing this problem, we measure the temperature dependence of the volume plasmon energy in silicon nanoparticles from room temperature to 1250 °C , using a chip-style heating sample holder in a scanning transmission electron microscope (STEM) equipped with electron energy loss spectroscopy (EELS). The plasmon energy changes as expected for an electron gas subject to the thermal expansion of silicon. Reversing this reasoning, we find that measurements of the plasmon energy provide an independent measure of the nanoparticle temperature consistent with that of the heater chip's macroscopic, dual-function heater-and-thermometer to within the 5% accuracy of the thermometer's calibration. Thus, silicon has the potential to provide its own high-spatial-resolution thermometric readout signal via measurements of its volume plasmon energy. Furthermore, nanoparticles can, in general, serve as convenient nanothermometers for in situ electron-microscopy experiments.
Electronic Thermometer Readings
NASA Technical Reports Server (NTRS)
2001-01-01
NASA Stennis' adaptive predictive algorithm for electronic thermometers uses sample readings during the initial rise in temperature and applies an algorithm that accurately and rapidly predicts the steady state temperature. The final steady state temperature of an object can be calculated based on the second-order logarithm of the temperature signals acquired by the sensor and predetermined variables from the sensor characteristics. These variables are calculated during tests of the sensor. Once the variables are determined, relatively little data acquisition and data processing time by the algorithm is required to provide a near-accurate approximation of the final temperature. This reduces the delay in the steady state response time of a temperature sensor. This advanced algorithm can be implemented in existing software or hardware with an erasable programmable read-only memory (EPROM). The capability for easy integration eliminates the expense of developing a whole new system that offers the benefits provided by NASA Stennis' technology.
Onsite Calibration of a Precision IPRT Based on Gallium and Gallium-Based Small-Size Eutectic Points
NASA Astrophysics Data System (ADS)
Sun, Jianping; Hao, Xiaopeng; Zeng, Fanchao; Zhang, Lin; Fang, Xinyun
2017-04-01
Onsite thermometer calibration with temperature scale transfer technology based on fixed points can effectively improve the level of industrial temperature measurement and calibration. The present work performs an onsite calibration of a precision industrial platinum resistance thermometer near room temperature. The calibration is based on a series of small-size eutectic points, including Ga-In (15.7°C), Ga-Sn (20.5°C), Ga-Zn (25.2°C), and a Ga fixed point (29.7°C), developed in a portable multi-point automatic realization apparatus. The temperature plateaus of the Ga-In, Ga-Sn, and Ga-Zn eutectic points and the Ga fixed point last for longer than 2 h, and their reproducibility was better than 5 mK. The device is suitable for calibrating non-detachable temperature sensors in advanced environmental laboratories and industrial fields.
Compensation for effects of ambient temperature on rare-earth doped fiber optic thermometer
NASA Technical Reports Server (NTRS)
Adamovsky, G.; Sotomayor, J. L.; Krasowski, M. J.; Eustace, J. G.
1989-01-01
Variations in ambient temperature have a negative effect on the performance of any fiber optic sensing system. A change in ambient temperature may alter the design parameters of fiber optic cables, connectors, sources, detectors, and other fiber optic components and eventually the performance of the entire system. The thermal stability of components is especially important in a system which employs intensity modulated sensors. Several referencing schemes have been developed to account for the variable losses that occur within the system. However, none of these conventional compensating techniques can be used to stabilize the thermal drift of the light source in a system based on the spectral properties of the sensor material. The compensation for changes in ambient temperature becomes especially important in fiber optic thermometers doped with rare earths. Different approaches to solving this problem are searched and analyzed.
Compensation for effects of ambient temperature on rare-earth doped fiber optic thermometer
NASA Technical Reports Server (NTRS)
Adamovsky, G.; Sotomayor, J. L.; Krasowski, M. J.; Eustace, J. G.
1990-01-01
Variations in ambient temperature have a negative effect on the performance of any fiber optic sensing system. A change in ambient temperature may alter the design parameters of fiber optic cables, connectors, sources, detectors, and other fiber optic components and eventually the performance of the entire system. The thermal stability of components is especially important in a system which employs intensity modulated sensors. Several referencing schemes have been developed to account for the variable losses that occur within the system. However, none of these conventional compensating techniques can be used to stabilize the thermal drift of the light source in a system based on the spectral properties of the sensor material. The compensation for changes in ambient temperature becomes especially important in fiber optic thermometers doped with rare earths. Different approaches to solving this problem are searched and analyzed.
Development of a test method against hot alkaline chemical splashes.
Mäkinen, Helena; Nieminen, Kalevi; Mäki, Susanna; Siiskonen, Sirkku
2008-01-01
High temperature alkaline chemical liquids have caused injuries and hazardous situations in Finnish pulp manufacturing mills. There are no requirements and/or test method standards concerning protection against high temperature alkaline chemical splashes. This paper describes the test method development process to test and identify materials appropriate for hot liquid chemical hazard protection. In the first phase, the liquid was spilled through a stainless steel funnel and the protection performance was evaluated using a polyvinyl chloride (PVC) film under the test material. After several tentative improvements, a graphite crucible was used for heating and spilling the chemical, and a copper-coated K-type thermometer with 4 independent measuring areas was designed to measure the temperature under the material samples. The thermometer was designed to respond quickly so that peak temperatures could be measured. The main problem was to keep the spilled amount of chemical constant, which unfortunately resulted in significant variability in data.
Warmer and wetter 6000 years ago?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beck, W.
1998-02-13
The author discusses recent work on thermometer systems which can be used to study past climatic temperatures. The {sup 18}O/{sup 16}O isotope ratio of marine carbonates was originally expected to provide a definitive answer following its introduction. However this ratio has been shown to be a function of temperature and the isotope ratio in seawater, which has been seen to vary on glacial time scales. Recent work to link the {sup 18}O/{sup 16}O isotope ratio with the Sr/Ca ratio measurement in corals has shown promise to factor out some of this variability. One interpretation of recent work with 6000 yearmore » corals is that sea temperatures were 1.2{degrees}C warmer, and the extratropics should have been wetter. The authors discuss other interpretations, and additional work to validate the use of these types of thermometer systems.« less
Nanoelectronic primary thermometry below 4 mK
Bradley, D. I.; George, R. E.; Gunnarsson, D.; Haley, R. P.; Heikkinen, H.; Pashkin, Yu. A.; Penttilä, J.; Prance, J. R.; Prunnila, M.; Roschier, L.; Sarsby, M.
2016-01-01
Cooling nanoelectronic structures to millikelvin temperatures presents extreme challenges in maintaining thermal contact between the electrons in the device and an external cold bath. It is typically found that when nanoscale devices are cooled to ∼10 mK the electrons are significantly overheated. Here we report the cooling of electrons in nanoelectronic Coulomb blockade thermometers below 4 mK. The low operating temperature is attributed to an optimized design that incorporates cooling fins with a high electron–phonon coupling and on-chip electronic filters, combined with low-noise electronic measurements. By immersing a Coulomb blockade thermometer in the 3He/4He refrigerant of a dilution refrigerator, we measure a lowest electron temperature of 3.7 mK and a trend to a saturated electron temperature approaching 3 mK. This work demonstrates how nanoelectronic samples can be cooled further into the low-millikelvin range. PMID:26816217
Stop outbreak of SARS with infrared cameras
NASA Astrophysics Data System (ADS)
Wu, Yigang M.
2004-04-01
SARS (Severe Acute Respiratory Syndrome, commonly known as Atypical Pneumonia in mainland China) caused 8422 people affected and resulting in 918 deaths worldwide in half year. This disease can be transmitted by respiratory droplets or by contact with a patient's respiratory secretions. This means it can be spread out very rapidly through the public transportations by the travelers with the syndrome. The challenge was to stop the SARS carriers traveling around by trains, airplanes, coaches and etc. It is impractical with traditional oral thermometers or spot infrared thermometers to screen the tens of travelers with elevated body temperature from thousands of normal travelers in hours. The thermal imager with temperature measurement function is a logical choice for this special application although there are some limitations and drawbacks. This paper discusses the real SARS applications of industrial infrared cameras in China from April to July 2003.
The research on the temperature measurement technology of aluminum atomic emission spectroscopy
NASA Astrophysics Data System (ADS)
Hu, Xiaotao; Hao, Xiaojian; Tang, Huijuan; Sun, Yongkai
2018-02-01
Aimed to the testing requirement of the transient high temperature in the bore of barrel weapon, which has the problems of high temperature, high pressure, high overload and narrow adverse environment, the photoelectric pyrometer was researched based on the temperature measurement technology of double line of atomic emission spectrum and storage measurement technology, which used silicon photomultiplier. Al I 690.6nm and 708.5nm were selected as the temperature measurement element spectral lines, spectral line intensity was converted into a voltage value by silicon photomultiplier, the temperature was obtained through the ratio of two spectrum lines. The temperature is measured by the photoelectric thermometer and the infrared thermometer when heating aluminum by oxyhydrogen flame, and the relative error was 1.75%. Results show the temperature dependence of the two methods is better, and prove the feasibility of the method.
Optical Probe of the Superconducting Normal Mixed State in a Magnetic Penetration Thermometer
NASA Technical Reports Server (NTRS)
Stevenson, T. R.; Balvin, M. A.; Bandler, S. R.; Denis, K. L.; Lee, S. -J.; Nagler, P. C.; Smith, S. J.
2016-01-01
Using ultraviolet photon pulses, we have probed the internal behavior of a molybdenum-gold Magnetic Penetration Thermometer (MPT) that we designed for x-ray microcalorimetry. In this low-temperature detector, the diamagnetic response of a superconducting MoAu bilayer is used to sense temperature changes in response to absorbed photons. We have previously described an approximate model that explains the high responsivity of the detector to temperature changes as a consequence of a Meissner transition of the molybdenum-gold film in the magnetic field applied by the superconducting circuit used to bias the detector. We compare measurements of MPT heat capacity and thermal conductance, derived from UV photon pulse data, to our model predictions for the thermodynamic properties of the sensor and for the electron cooling obtained by quasiparticle recombination. Our data on electron cooling power is also relevant to the operation of other superconducting detectors, such as Microwave Kinetic Inductance Detectors.
Nanothermometer Based on Resonant Tunneling Diodes: From Cryogenic to Room Temperatures.
Pfenning, Andreas; Hartmann, Fabian; Rebello Sousa Dias, Mariama; Castelano, Leonardo Kleber; Süßmeier, Christoph; Langer, Fabian; Höfling, Sven; Kamp, Martin; Marques, Gilmar Eugenio; Worschech, Lukas; Lopez-Richard, Victor
2015-06-23
Sensor miniaturization together with broadening temperature sensing range are fundamental challenges in nanothermometry. By exploiting a large temperature-dependent screening effect observed in a resonant tunneling diode in sequence with a GaInNAs/GaAs quantum well, we present a low dimensional, wide range, and high sensitive nanothermometer. This sensor shows a large threshold voltage shift of the bistable switching of more than 4.5 V for a temperature raise from 4.5 to 295 K, with a linear voltage-temperature response of 19.2 mV K(-1), and a temperature uncertainty in the millikelvin (mK) range. Also, when we monitor the electroluminescence emission spectrum, an optical read-out control of the thermometer is provided. The combination of electrical and optical read-outs together with the sensor architecture excel the device as a thermometer with the capability of noninvasive temperature sensing, high local resolution, and sensitivity.
Mobile In Vivo Infrared Data Collection and Diagnoses Comparison System
NASA Technical Reports Server (NTRS)
Mintz, Frederick W. (Inventor); Gunapala, Sarath D. (Inventor); Moynihan, Philip I. (Inventor)
2013-01-01
Described is a mobile in vivo infrared brain scan and analysis system. The system includes a data collection subsystem and a data analysis subsystem. The data collection subsystem is a helmet with a plurality of infrared (IR) thermometer probes. Each of the IR thermometer probes includes an IR photodetector capable of detecting IR radiation generated by evoked potentials within a user's skull. The helmet is formed to collect brain data that is reflective of firing neurons in a mobile subject and transmit the brain data to the data analysis subsystem. The data analysis subsystem is configured to generate and display a three-dimensional image that depicts a location of the firing neurons. The data analysis subsystem is also configured to compare the brain data against a library of brain data to detect an anomaly in the brain data, and notify a user of any detected anomaly in the brain data.
NASA Astrophysics Data System (ADS)
Zhang, Yan; Zhang, Yuzhong; Lu, Rongsheng; Shu, Shuangbao; Lang, Xianli; Yang, Lei
2018-01-01
Molybdenum (Mo) is an important material to construct the first wall for the Experimental Advanced Superconducting Tokamak (EAST). The real-time monitoring of temperature distribution of the first wall based on radiation thermometry is essential to guarantee the stable operation of EAST. So, it is especially important for the acquisition of emissivity property of Mo. In this work, a self-designed emissivity measurement apparatus is developed, and the relationship between the normal infrared spectral band (7.5-13 μm) emissivity of Mo against the temperature and surface roughness of material samples is experimentally investigated under the vacuum condition over the temperature ranging from 100 °C to 500 °C. Moreover, the dependence of spectral band emissivity of Mo exposed to air on the heating-duration time at a given elevated temperature is also studied. The emissivity measurement apparatus is mainly composed of a high temperature furnace and a radiation thermometer as well as a benchmark blackbody furnace. The radiation thermometer is firstly calibrated against the blackbody furnace by means of the multi-temperature methods. And then the temperature of the sample is simultaneously measured by the two highly accurate S-type thermocouples and the radiation thermometer. Finally the emissivity value of the sample is calculated based on the direct radiometric method. The developed emissivity measurement method and experimental results obtained in this work may be helpful to understand the work state the EAST and to use of Mo as an emissivity reference.
Tuned-circuit dual-mode Johnson noise thermometers
NASA Astrophysics Data System (ADS)
Shepard, R. L.; Carroll, R. M.; Falter, D. D.; Blalock, T. V.; Roberts, M. J.
1992-02-01
Dual-mode Johnson noise and direct current (DC) resistance thermometers can be used in control systems where prompt indications of temperature changes and long-term accuracy are needed. Such a thermometer is being developed for the SP-100 space nuclear electric power system that requires temperature measurement at 1400 K in space for 10 years, of which 7 are expected to be at full reactor power. Several direct coupled and transformer coupled, tuned resistance inductance capacitance (RLC) circuits that produce a single, continuous voltage signal were evaluated for noise temperature measurement. The simple direct coupled RLC circuit selected provides a mean squared noise voltage that depends only on the capacitance used and the temperature of the sensor, and it is independent of the value of or changes in the sensor resistance. These circuits provide a noise signal with long term accuracy but require integrating noise signals for a finite length of time. The four wire resistor for the noise temperature sensor allows simultaneous DC resistance measurements to be made that provide a prompt, continuous temperature indication signal. The DC current mode is employed continuously, and a noise voltage measurement is made periodically to correct the temperature indication. The differential noise voltage preamplifier used substantially reduces electromagnetic interference (EMI) in the system. A sensor has been tested that should provide good performance (+/- 1 percent accuracy) and long-term (10 year) reliability in space environments. Accurate noise temperature measurements were made at temperatures above 1300 K, where significant insulator shunting occurs, even though shunting does affect the dc resistance measurements and makes the system more susceptible to EMI.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duncan, R.V.
1988-01-01
A new type of paramagnetic susceptibility thermometry called toroidal magnetic thermometry (TMT) has been developed. These TMT thermometers have a thermal resolution of five nanoKelvin near the {sup 4}He superfluid transition temperature T{lambda} = 2.172K, making TMT roughly a factor of fifty times better in resolution than conventional germanium resistance thermometry which is commercially available. The dramatic improvement in thermal resolution provided by TMT has been used to observe new phenomena associated with the superfluid transition in pure liquid {sup 4}He. Such phenomena include a component of the thermal boundary (Kapitza) resistance R{sub K} which is singular at the superfluidmore » transition temperature T{lambda}. In addition to the boundary effects described above, these TMT thermometers have been used to detect the depression of T{lambda} be a heat current Q flowing through the liquid helium. When these values of {Delta}T{lambda}(Q) were used to calculate the depression of the superfluid density {Delta}{rho}{sub s}(Q) the results agreed well with a prediction based on the theory of Ginzburg and Pitaevskii. The calibration of the TMT thermometers provide high-resolution measurements of the a.c. paramagnetic susceptibility of their magnetic salt: Copper ammonium bromide (CAB). These calibration parameters, together with power dissipation data near the CAB Curie temperature {Tc} = 1.79K, provide information on the magnetic critical behavior of this nearly ideal Heisenberg ferromagnet. Throughout the detailed description of the TMT design, aspects of the CAB magnetic critical phenomena are discussed.« less
Future Development Trajectories for Imaging X-rays Spectrometers Based on Microcalorimeters
NASA Technical Reports Server (NTRS)
Kilbourne, Caroline A.; Bandler, Simon R.
2013-01-01
Future development trajectories for imaging x-ray spectrometers based on microcalorimeters. Since their invention 30 years ago, the capability of X-ray microcalorimeters has increased steadily, with continual improvements in energy resolution, speed, and array size. Arrays of up to 1024 pixels have been produced, and resolution better than 1 eV at 1.5 keV has been achieved. These detectors can be optimized for the highest priority science, such as designing for the highest resolving power at low energies at the expense of dynamic range, or the greatest focal-plane coverage at the expense of speed. Three types of X-ray microcalorimeters presently dominate the field, each characterized by the thermometer technology. The first two types use temperature-sensitive resistors: semiconductors in the metal-insulator transition and superconductors operated in the superconducting-normal transition. The third type uses a magnetically coupled thermometer, and is at an earlier stage of development than the other two. The Soft X-ray Spectrometer (SXS) on Astro-H, expected to launch in 2015, will use an array of silicon thermistors with HgTe X-ray absorbers that will operate at 50 mK. Both the semiconductor and superconductor calorimeters have been implemented in small arrays. Kilopixel arrays of the superconducting calorimeters are being produced, and much larger arrays may require the non-dissipative advantage of magnetically coupled thermometers. I will project the development trajectories of these detectors and their read-out technologies and assess what their capabilities and limitations will be 10 - 20 years from now.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cárdenas-García, D.; Méndez-Lango, E.
Flat Calibrators (FC) are an option for calibration of infrared thermometers (IT) with a fixed large target. FCs are neither blackbodies, nor gray-bodies; their spectral emissivity is lower than one and depends on wavelength. Nevertheless they are used as gray-bodies with a nominal emissivity value. FCs can be calibrated radiometrically using as reference a calibrated IR thermometer (RT). If an FC will be used to calibrate ITs that work in the same spectral range as the RT then its calibration is straightforward: the actual FC spectral emissivity is not required. This result is valid for any given fixed emissivity assessedmore » to the FC. On the other hand, when the RT working spectral range does not match with that of the ITs to be calibrated with the FC then it is required to know the FC spectral emissivity as part of the calibration process. For this purpose, at CENAM, we developed an experimental setup to measure spectral emissivity in the infrared spectral range, based on a Fourier transform infrared spectrometer. Not all laboratories have emissivity measurement capability in the appropriate wavelength and temperature ranges to obtain the spectral emissivity. Thus, we present an estimation of the error introduced when the spectral range of the RT used to calibrate an FC and the spectral ranges of the ITs to be calibrated with the FC do not match. Some examples are developed for the cases when RT and IT spectral ranges are [8,13] μm and [8,14] μm respectively.« less
16 CFR § 1500.43a - Method of test for flashpoint of volatile flammable materials.
Code of Federal Regulations, 2013 CFR
2013-01-01
... between the temperature control dial and the thermometer readings at each major (numbered) dial division... block of suitable conductivity with a cylindrical depression, or sample cup, over which is fitted a...
176. Photographic copy of original construction drawing dated February 10, ...
176. Photographic copy of original construction drawing dated February 10, 1933 (from Record Group 115, Denver Branch of the National Archives, Denver). OWYHEE DAM; LOCATION OF THERMOMETER GROUPS. - Owyhee Dam, Across Owyhee River, Nyssa, Malheur County, OR
Giansanti, Daniele
2008-07-01
A wearable device for skin-contact thermography [Giansanti D, Maccioni G. Development and testing of a wearable integrated thermometer sensor for skin contact thermography. Med Eng Phys 2006 [ahead of print
Code of Federal Regulations, 2011 CFR
2011-07-01
... volatilize and recover perchloroethylene from contaminated perchloroethylene. Temperature sensor means a thermometer or thermocouple used to measure temperature. Transfer machine system means a multiple-machine dry... December 9, 1991. PCE gas analyzer means a flame ionization detector, photoionization detector, or infrared...
Code of Federal Regulations, 2014 CFR
2014-07-01
... volatilize and recover perchloroethylene from contaminated perchloroethylene. Temperature sensor means a thermometer or thermocouple used to measure temperature. Transfer machine system means a multiple-machine dry... December 9, 1991. PCE gas analyzer means a flame ionization detector, photoionization detector, or infrared...
Code of Federal Regulations, 2010 CFR
2010-07-01
... volatilize and recover perchloroethylene from contaminated perchloroethylene. Temperature sensor means a thermometer or thermocouple used to measure temperature. Transfer machine system means a multiple-machine dry... December 9, 1991. PCE gas analyzer means a flame ionization detector, photoionization detector, or infrared...
Code of Federal Regulations, 2013 CFR
2013-07-01
... volatilize and recover perchloroethylene from contaminated perchloroethylene. Temperature sensor means a thermometer or thermocouple used to measure temperature. Transfer machine system means a multiple-machine dry... December 9, 1991. PCE gas analyzer means a flame ionization detector, photoionization detector, or infrared...
Code of Federal Regulations, 2012 CFR
2012-07-01
... volatilize and recover perchloroethylene from contaminated perchloroethylene. Temperature sensor means a thermometer or thermocouple used to measure temperature. Transfer machine system means a multiple-machine dry... December 9, 1991. PCE gas analyzer means a flame ionization detector, photoionization detector, or infrared...
Determining Absolute Zero in the Kitchen Sink.
ERIC Educational Resources Information Center
Otani, Robert; Siegel, Peter
1991-01-01
Presents an experiment to demonstrate Charles's Law of Ideal Gases by creating a constant-pressure thermometer from materials that can be found in the kitchen. Discusses the underlying mathematical relationships and a step-by-step description of the experiment. (MDH)
27 CFR 30.23 - Use of precision hydrometers and thermometers.
Code of Federal Regulations, 2011 CFR
2011-04-01
... observed. Bulk spirits should be thoroughly agitated so that the test samples will be representative of the... should be inserted in the liquid and the hydrometer bulb raised and lowered from top to bottom 5 or 6...
Rampling, Jeremy; Mitchell, Alex J; Von Oertzen, Tim; Docker, James; Jackson, Jemima; Cock, Hannah; Agrawal, Niruj
2012-10-01
Depression is an important but underdiagnosed complication of epilepsy. This study compares potentially suitable screening tools head-to-head. We enrolled 266 attendees with a confirmed diagnosis of epilepsy at a specialized neurologic epilepsy service in London and compared verbal self-report and visual analog (VAS) screening methods for depression. These included two generic depression scales (Hospital Anxiety and Depression Scale [HADS], Beck Depression Inventory II [BDI-II]), one epilepsy specific scale (Neurological Disorders Depression Inventory for Epilepsy [NDDI-E]) and one new visual-analog scale (Emotional Thermometers [ET]). We used Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) criteria for major depression and International Classification of Diseases, Tenth Revision (ICD-10) criteria for depressive episode as the reference standard. Against ICD-10-defined depression the most accurate scales by receiver operating characteristic (ROC) curve area were HADS Total (HADS-T, 0.924), BDI-II (0.898) and NDDI-E (0.897). New visual-analog methods had similar accuracy measured either in combination or individually. Although no test performed well in a case-finding role, several performed well as a rule-out initial step, owing to high negative predictive value and specificity. In this role, the optimal performing conventional tools were the HADS depression subsscale (HADS-D) and the NDDI-E and the optimal single VAS were the depression thermometer (DepT) and the distress thermometer (DT). Against DSM-IV- defined major depression, results were similar with optimal performance by the HADS-T, BDI-II, and NDDI-E, but here the anxiety thermometer (AnxT) as well as DepT and DT also offered good performance. Given that no test performed well in a case-finding role, we suggest that these tests are used as an initial first step to rule out patients who are unlikely to have depression. We suggest that the six-item NDDI-E or seven-item HADS-D should be considered if a conventional scale is preferred and that the revised ET4 be considered if a visual-analog method is required. Follow-up examination and intervention, where indicated, are necessary in all those who screen positive on any measure as these are not intended as diagnostic tools. Wiley Periodicals, Inc. © 2012 International League Against Epilepsy.
NASA Astrophysics Data System (ADS)
Marciniak, L.; Prorok, K.; Francés-Soriano, L.; Pérez-Prieto, J.; Bednarkiewicz, A.
2016-02-01
The chemical architecture of lanthanide doped core-shell up-converting nanoparticles can be engineered to purposely design the properties of luminescent nanomaterials, which are typically inaccessible to their homogeneous counterparts. Such an approach allowed to shift the up-conversion excitation wavelength from ~980 to the more relevant ~808 nm or enable Tb or Eu up-conversion emission, which was previously impossible to obtain or inefficient. Here, we address the issue of limited temperature sensitivity range of optical lanthanide based nano-thermometers. By covering Yb-Er co-doped core nanoparticles with the Yb-Nd co-doped shell, we have intentionally combined temperature dependent Er up-conversion together with temperature dependent Nd --> Yb energy transfer, and thus have expanded the temperature response range ΔT of a single nanoparticle based optical nano-thermometer under single ~808 nm wavelength photo-excitation from around ΔT = 150 K to over ΔT = 300 K (150-450 K). Such engineered nanocrystals are suitable for remote optical temperature measurements in technology and biotechnology at the sub-micron scale.The chemical architecture of lanthanide doped core-shell up-converting nanoparticles can be engineered to purposely design the properties of luminescent nanomaterials, which are typically inaccessible to their homogeneous counterparts. Such an approach allowed to shift the up-conversion excitation wavelength from ~980 to the more relevant ~808 nm or enable Tb or Eu up-conversion emission, which was previously impossible to obtain or inefficient. Here, we address the issue of limited temperature sensitivity range of optical lanthanide based nano-thermometers. By covering Yb-Er co-doped core nanoparticles with the Yb-Nd co-doped shell, we have intentionally combined temperature dependent Er up-conversion together with temperature dependent Nd --> Yb energy transfer, and thus have expanded the temperature response range ΔT of a single nanoparticle based optical nano-thermometer under single ~808 nm wavelength photo-excitation from around ΔT = 150 K to over ΔT = 300 K (150-450 K). Such engineered nanocrystals are suitable for remote optical temperature measurements in technology and biotechnology at the sub-micron scale. Electronic supplementary information (ESI) available: Characterization, structural and morphological characterization of nanocrystals, the measurement setup. See DOI: 10.1039/c5nr08223d
NASA Astrophysics Data System (ADS)
Norranim, Uthai; Nguyen, Mong Kim; Ballico, Mark J.
2007-01-01
Industrial thermometers such as industrial platinum resistance thermometers (iprts) and liquid-in-glass thermometers (LIGTs) are widely used in industry. Because Key Comparisons are limited to direct realizations of ITS-90, and not all APMP NMIs have participated in them, the national metrology institutes (NMIs) of Thailand and Australia (NIMT and NIMA) organized an APMP supplementary comparison to support the approval of CMCs (calibration and measurement capabilities) for these laboratories. The comparison, performed in 2003, covered the range from -40.0 °C to 250.0 °C, using IPRTs (Hart Scientific 5626-12-S), total immersion (ASTM 62C, 120C) and partial immersion (ASTM 40C) LIGTs. Ten NMIs from the APMP: KIM-LIPI (Indonesia), ITDI (Philippines), MSL (New Zealand), NBSM (Nepal), NMIA (Australia), NIMT (Thailand), SCL (Hong Kong), SIRIM (Malaysia), SPRING (Singapore) and VMI (Vietnam) were divided into two loops to shorten the circulation time, and these were linked by the two pilot laboratories. This report describes details of the artifacts, the circulation schedule, the measurement procedures, the results submitted by participants, uncertainties and the analysis of the results. Reference values calculated using simple mean, median and weighted mean were consistent with each other, but as the Birge criterion was satisfied, the weighted mean with its lower uncertainty was adopted. The artifacts were found to be stable over the comparison and the results of the loop linking labs consistent, allowing an uncertainty of 2 mK to 4 mK to be achieved for the IPRT reference value and 10 mK to 20 mK for the LIGT reference values. These uncertainties allowed the comparison data to be used to adequately test the uncertainties of all the participant laboratories, and hence to directly support their CMC claims. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
49 CFR 179.100-13 - Venting, loading and unloading valves, measuring and sampling devices.
Code of Federal Regulations, 2010 CFR
2010-10-01
... permit testing thermometer well for leaks without complete removal of the closure may be used. (d) An... cast, forged or fabricated metal. Each sump or siphon bowl must be of good welding quality in...
Code of Federal Regulations, 2010 CFR
2010-04-01
... part. (b) Proprietors. Proprietors shall use only accurate hydrometers and thermometers that show... described in § 30.22. (c) Appropriate TTB officers. Appropriate TTB officers shall use only hydrometers and... hydrometer, TTB officers shall use precision grade specific gravity hydrometers conforming to the provisions...
ERIC Educational Resources Information Center
School Science Review, 1978
1978-01-01
Describes some science apparatus: included are a gene kit to demonstrate aspects of population genetics and selection, an electronic thermometer for use in the field of environmental studies, an astrobrella to use in astronomy classes, and crystal display models of different substances for chemistry classes. (GA)
ERIC Educational Resources Information Center
Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.
This booklet presents some activities to measure various weather phenomena. Directions for constructing a weather station are included. Instruments including rain gauges, thermometers, wind vanes, wind speed devices, humidity devices, barometers, atmospheric observations, a dustfall jar, sticky-tape can, detection of gases in the air, and pH of…
NASA's New 'Plant Thermometer' Undergoes Inspection
2018-06-11
A technician inspects NASA's ECOSTRESS instrument in a clean room at Kennedy Space Center in Florida. ECOSTRESS measures the temperature of plants, which shows how they are regulating their water use in response to heat stress. https://photojournal.jpl.nasa.gov/catalog/PIA22509
IRIS Toxicological Review of Thallium and Compounds (External Review Draft)
Thallium compounds are used in the semiconductor industry, the manufacture of optic lenses and low-melting glass, low-temperature thermometers, alloys, electronic devices, mercury lamps, fireworks, and imitation germs, and clinically as an imaging agent in the diagnosis of certai...
Food Handling Behaviors Observed in Consumers When Cooking Poultry and Eggs.
Maughan, Curtis; Chambers, Edgar; Godwin, Sandria; Chambers, Delores; Cates, Sheryl; Koppel, Kadri
2016-06-01
Previous research has shown that many consumers do not follow recommended food safety practices for cooking poultry and eggs, which can lead to exposure to Salmonella and Campylobacter. Past research has been done primarily through surveys and interviews, rather than observations. The objective of this project was to determine through observations whether consumers follow food safety guidelines. Consumers (n = 101) divided among three locations (Manhattan, KS; Kansas City, MO area; and Nashville, TN) were observed as they prepared a baked whole chicken breast, a pan-fried ground turkey patty, a fried egg, and scrambled eggs. The end point temperature for the cooked products was taken (outside the view of consumers) within 30 s after the consumers indicated they were finished cooking. Thermometer use while cooking was low, although marginally higher than that of some previous studies: only 37% of consumers used a thermometer for chicken breasts and only 22% for turkey patties. No one used a thermometer for fried or scrambled eggs. Only 77% of the chicken and 69% of the turkey was cooked to a safe temperature (165°F [74°C]), and 77% of scrambled and 49% of fried eggs reached a safe temperature (160°F [71°C]). Safe hand washing was noted in only 40% of respondents after handling the chicken breast and 44% after handling the ground turkey patty. This value decreased to 15% after handling raw eggs for fried eggs and to 17% for scrambled eggs. These results show that there is a high prevalence of unsafe behaviors (undercooking and poor hand washing technique) when cooking poultry and eggs and a great need for improvement in consumer behavior with poultry and eggs.
NASA Technical Reports Server (NTRS)
2003-01-01
There are two requirements for taking a measurement of something. The first is a tool for taking a measurement. The second is scale for making sense of the numbers of the measurement. For example, a ruler is often used to measure short lengths. It is the tool for measurement. On the ruler are one or more number scales with equally spaced numbers. These numbers can be compared with numbers from any other ruler that is accurately set to the same scale. Measuring length is far simpler than measuring temperature. While there is evidence of tools for measuring length at various times in human history, tools and scales for measuring temperature do not appear until more recent human history. Early thermometers, called thermoscopes, first appear in the 1500's. They were crude instruments that were not at all accurate. Most did not even have a number scale associated with them. This made them useless for most practical purposes. Gabriel Fahrenheit created the first accurate thermometer in 1714, and the Fahrenheit temperature scale followed it in 1724. The thermometer s accuracy was based on its use of mercury, a silver colored substance that remains liquid over a wide range of temperatures but expands or contracts in a standard, predictable way with changes in temperature. To set the scale, Fahrenheit created the coldest temperature that he could. He mixed equal parts of ice, water, and salt, and then used this as the zero point, 0 degrees, of his scale. He intended to make 30 degrees the freezing point of water and 90 degrees the temperature of the human body, but he had to later revise these temperatures to be 32 degrees and 96 degrees. In the final version of the scale, the temperature of the human body became 98.6 degrees. 19th century thermoscope
Kortmann, Jens; Seekircher, Stephanie; Heroven, Ann Kathrin; Berger, Evelin; Pisano, Fabio; Thiermann, Tanja; Wolf-Watz, Hans; Narberhaus, Franz; Dersch, Petra
2012-01-01
Expression of all Yersinia pathogenicity factors encoded on the virulence plasmid, including the yop effector and the ysc type III secretion genes, is controlled by the transcriptional activator LcrF in response to temperature. Here, we show that a protein- and RNA-dependent hierarchy of thermosensors induce LcrF synthesis at body temperature. Thermally regulated transcription of lcrF is modest and mediated by the thermo-sensitive modulator YmoA, which represses transcription from a single promoter located far upstream of the yscW-lcrF operon at moderate temperatures. The transcriptional response is complemented by a second layer of temperature-control induced by a unique cis-acting RNA element located within the intergenic region of the yscW-lcrF transcript. Structure probing demonstrated that this region forms a secondary structure composed of two stemloops at 25°C. The second hairpin sequesters the lcrF ribosomal binding site by a stretch of four uracils. Opening of this structure was favored at 37°C and permitted ribosome binding at host body temperature. Our study further provides experimental evidence for the biological relevance of an RNA thermometer in an animal model. Following oral infections in mice, we found that two different Y. pseudotuberculosis patient isolates expressing a stabilized thermometer variant were strongly reduced in their ability to disseminate into the Peyer's patches, liver and spleen and have fully lost their lethality. Intriguingly, Yersinia strains with a destabilized version of the thermosensor were attenuated or exhibited a similar, but not a higher mortality. This illustrates that the RNA thermometer is the decisive control element providing just the appropriate amounts of LcrF protein for optimal infection efficiency. PMID:22359501
Keene, Toby; Brearley, Matt; Bowen, Beth; Walker, Anthony
2015-10-01
In the course of their duties, firefighters risk heat stroke and other medical conditions due to exertion in high-temperature environments. Infrared tympanic temperature measurement (TTym) is often used by Emergency Medical Services (EMS) to assess the core body temperature of firefighters. The accuracy of TTym in this setting has been called into question. Hypothesis/Problem This study aimed to examine the accuracy of TTym for core body temperature assessment at emergency firefighting events compared with gastrointestinal temperature measurement (TGI) as measured by ingestible thermometers. Forty-five (42 male, three female) professional urban firefighters from an Australian fire service completed two 20-minute work periods in a 100°C (± 5°C) heat chamber while wearing personal protective clothing (PPC) and breathing apparatus (weighing approximately 22 kg). Measurements were taken immediately before entering, and on exiting, the heat chamber. Tympanic temperature was assessed by an infrared tympanic thermometer and TGI was measured by ingestible sensor and radio receiver. Complete data were available for 37 participants. Participant temperatures were higher on exiting the heat chamber than at baseline (TTym: 35.9°C (SD=0.7) vs 37.5°C (SD=0.8); TGI: 37.2°C (SD=0.4) vs 38.6°C (SD=0.5)). Tympanic temperature underestimated TGI on average by 1.3°C (SD=0.5) before entering the chamber and by 1.0°C (SD=0.8) following the exercise. Using pooled data, the average underestimation was 1.2°C (SD=0.7). Tympanic thermometers cause an unreliable measure of core body temperature for firefighters engaged in fire suppression activities. Accurate and practical measures of core body temperature are required urgently.
Microcalorimetry and the transition-edge sensor
NASA Astrophysics Data System (ADS)
Lindeman, Mark Anton
2000-10-01
Many scientific and industrial applications call for quantum-efficient high-energy-resolution microcalorimeters for the measurement of x rays. The applications driving the development of these detectors involve the measurement of faint sources of x rays in which few photons reach the detector. Interesting astrophysical applications for these microcalorimeters include the measurement of composition and temperatures of stellar atmospheres and diffuse interstellar plasmas. Other applications of microcalorimeter technology include x-ray fluorescence (XRF) measurements of industrial or scientific samples. We are attempting to develop microcalorimeters with energy resolutions of several eV because many sources (such as celestial plasmas) contain combinations of elements producing emission lines spaced only a few eV apart. Our microcalorimeters consist of a metal-film absorber (250mum x 250mum x 3mum of copper) coupled to a superconducting transition-edge-sensor (TES) thermometer. This microcalorimeter demonstrated an energy resolution of 42 eV (FWHM) at 6 keV, excellent linearity, and showed no evidence of position dependent response. The response of our microcalorimeters depends both on the temperature of the microcalorimeter and on the electrical current conducted through the TES thermometer. We present a microcalorimeter model that extends previous microcalorimeter theory to include additional current dependent effects. The model makes predictions about the effects of various forms of noise. In addition, the model helps us to understand what measurements are useful for characterizing TES microcalorimeters. While the energy resolution we obtained was quite good (twice as good as conventional semiconductor-based x-ray detectors), the obtained resolution was not as good as expected, due to excess noise from fluctuations in the TES thermometer. The energy resolution of future TES microcalorimeters can be improved by redesigning the calorimeters to minimize the noise due to these fluctuations.
Parental beliefs and practices regarding childhood fever in Turkish primary care.
Yavuz, E; Yayla, E; Cebeci, S E; Kırımlı, E; Gümüştakım, R Ş; Çakır, L; Doğan, S
2017-01-01
Fever is a very common problem in pediatric age and is one of the most common reasons parents seek medical attention. We aimed to investigate beliefs, habits, and concerns of Turkish parents regarding their children's fever. We performed a cross-sectional survey which was conducted as face-to-face interviews by family physicians from April to June 2014 in family healthcare centers in nine different cities in Turkey. Parents with a child with fever aged between 0 and 14 years were interviewed. The participants were asked questions about sociodemographic data, the definition and measurement of fever, antipyretics, and other interventions used to reduce fever before presenting to the primary care center. A total of 205 parents participated in this study. Ninety-four parents (45.8%) measured fever with a thermometer prior to presentation. Only 36 parents (38%) used the thermometer correctly. Thirty-eight parents (18.5%) knew the correct temperature definition of fever for the measured site. A mercury-in-glass thermometer was the choice for most parents (78%) and preferred site for measurement was axillary region (85%). The fever was treated prior to arrival by 171 parents (83.4%). Paracetamol was the most frequently used antipyretic. Fifty-four parents (31.5%) failed to administer the correct antipyretic dose, and 73 parents (42.6%) failed to give the antipyretics at proper intervals. One hundred and fifty-three parents (67%) believed that if not treated fever could cause convulsions. We conclude that parents share important misconceptions about definition, treatment, and consequences of childhood fever and tend to treat fever before seeking medical care with a substantial rate of wrong doses and wrong intervals.
Duran, Ridvan; Vatansever, Ulfet; Acunaş, Betül; Süt, Necdet
2009-01-01
Preterm infants are prone to temperature maintenance problems due to immature thermoregulatory mechanism and relatively large body surface area. The objective of the present study was to evaluate the performance of a new non-invasive infrared thermometer applied to the mid-forehead and temporal artery in comparison with axillary temperature recordings by mercury-in-glass thermometer, and to determine the discomfort caused by these procedures in preterm infants on incubator care. The present comparative prospective study was composed of 34 preterm infants <1500 g of birthweight nursed in an incubator. Temperature recording from mid-forehead, temporal artery and axilla were recorded six times a day for 7 days since the end of the first week of life. For pain assessment, the premature infant pain profile (PIPP) was used. The mean mid-forehead, temporal artery and axillary temperatures were 36.72 +/- 0.08, 36.81 +/- 0.09 and 36.71 +/- 0.07 degrees C, respectively. No statistically significant difference was noted between the means of mid-forehead and axillary temperatures. The mean temporal artery temperature was statistically higher than the means of the mid-forehead and axillary temperatures. The PIPP scores of the mid-forehead, temporal artery and axillary temperature measurements were 5.07 +/- 0.36 degrees C, 5.18 +/- 0.43 degrees C and 7.59 +/- 0.84 degrees C, respectively. The mean PIPP score of axillary temperature measurements was statistically higher than the means of mid-forehead and temporal artery measurements. The infrared skin thermometer applied to the mid-forehead is a useful and valid device for easy and less painful measurement of skin temperature in preterm infants <1500 g of birthweight.
Böhme, Katja; Steinmann, Rebekka; Kortmann, Jens; Seekircher, Stephanie; Heroven, Ann Kathrin; Berger, Evelin; Pisano, Fabio; Thiermann, Tanja; Wolf-Watz, Hans; Narberhaus, Franz; Dersch, Petra
2012-02-01
Expression of all Yersinia pathogenicity factors encoded on the virulence plasmid, including the yop effector and the ysc type III secretion genes, is controlled by the transcriptional activator LcrF in response to temperature. Here, we show that a protein- and RNA-dependent hierarchy of thermosensors induce LcrF synthesis at body temperature. Thermally regulated transcription of lcrF is modest and mediated by the thermo-sensitive modulator YmoA, which represses transcription from a single promoter located far upstream of the yscW-lcrF operon at moderate temperatures. The transcriptional response is complemented by a second layer of temperature-control induced by a unique cis-acting RNA element located within the intergenic region of the yscW-lcrF transcript. Structure probing demonstrated that this region forms a secondary structure composed of two stemloops at 25°C. The second hairpin sequesters the lcrF ribosomal binding site by a stretch of four uracils. Opening of this structure was favored at 37°C and permitted ribosome binding at host body temperature. Our study further provides experimental evidence for the biological relevance of an RNA thermometer in an animal model. Following oral infections in mice, we found that two different Y. pseudotuberculosis patient isolates expressing a stabilized thermometer variant were strongly reduced in their ability to disseminate into the Peyer's patches, liver and spleen and have fully lost their lethality. Intriguingly, Yersinia strains with a destabilized version of the thermosensor were attenuated or exhibited a similar, but not a higher mortality. This illustrates that the RNA thermometer is the decisive control element providing just the appropriate amounts of LcrF protein for optimal infection efficiency.
How To...Activities in Meteorology.
ERIC Educational Resources Information Center
Nimmer, Donald N.; Sagness, Richard L.
This series of experiments seeks to provide laboratory exercises which demonstrate concepts in Earth Science, particularly meteorology. Materials used in the experiments are easily obtainable. Examples of experiments include: (1) making a thermometer; (2) air/space relationship; (3) weight of air; (4) barometers; (5) particulates; (6) evaporation;…
Irrigation scheduling and controlling crop water use efficiency with Infrared Thermometry
USDA-ARS?s Scientific Manuscript database
Scientific methods for irrigation scheduling include weather, soil and plant-based techniques. Infrared thermometers can be used a non-invasive practice to monitor canopy temperature and better manage irrigation scheduling. This presentation will discuss the theoretical basis for monitoring crop can...
Code of Federal Regulations, 2012 CFR
2012-04-01
... thermometers furnished by the Government. However, where this part requires the use of a specific gravity hydrometer, TTB officers shall use precision grade specific gravity hydrometers conforming to the provisions... determination of specific gravity and for gauging. From time to time appropriate TTB officers shall verify the...
Code of Federal Regulations, 2014 CFR
2014-04-01
... thermometers furnished by the Government. However, where this part requires the use of a specific gravity hydrometer, TTB officers shall use precision grade specific gravity hydrometers conforming to the provisions... determination of specific gravity and for gauging. From time to time appropriate TTB officers shall verify the...
Code of Federal Regulations, 2011 CFR
2011-04-01
... thermometers furnished by the Government. However, where this part requires the use of a specific gravity hydrometer, TTB officers shall use precision grade specific gravity hydrometers conforming to the provisions... determination of specific gravity and for gauging. From time to time appropriate TTB officers shall verify the...
Code of Federal Regulations, 2013 CFR
2013-04-01
... thermometers furnished by the Government. However, where this part requires the use of a specific gravity hydrometer, TTB officers shall use precision grade specific gravity hydrometers conforming to the provisions... determination of specific gravity and for gauging. From time to time appropriate TTB officers shall verify the...
Design of affordable and ruggedized biomedical devices using virtual instrumentation.
Mathern, Ryan Michael; Schopman, Sarah; Kalchthaler, Kyle; Mehta, Khanjan; Butler, Peter
2013-05-01
Abstract This paper presents the designs of four low-cost and ruggedized biomedical devices, including a blood pressure monitor, thermometer, weighing scale and spirometer, designed for the East African context. The design constraints included a mass-production price point of $10, accuracy and precision comparable to commercial devices and ruggedness to function effectively in the harsh environment of East Africa. The blood pressure device, thermometer and weighing scale were field-tested in Kenya and each recorded data within 6% error of the measurements from commercial devices and withstood the adverse climate and rough handling. The spirometer functioned according to specifications, but a re-design is needed to improve operability and usability by patients. This article demonstrates the feasibility of designing and commercializing virtual instrumentation-based biomedical devices in resource-constrained environments through context-driven design. The next steps for the devices include designing them such that they can be more easily manufactured, use standardized materials, are easily calibrated in the field and have more user-friendly software programs that can be updated remotely.
Heat capacity and thermal relaxation of bulk helium very near the lambda point
NASA Technical Reports Server (NTRS)
Lipa, John A.; Swanson, D. R.; Nissen, J. A.; Chui, T. C. P.
1994-01-01
In October 1992 a low temperature experiment was flown on the Space Shuttle in low Earth orbit. The objective of the mission was to measure the heat capacity and thermal conductivity of helium very close to the lambda point with the smearing effect of gravity removed. We report preliminary results from the experiment, and compare them with related measurements performed on the ground. The sample was s sphere of helium 3.5 cm in diameter contained within a copper calorimeter of vey high thermal conductivity. The calorimeter was attached to a pair of high resolution paramagnetic salt thermometers with noise levels in the 10(exp -10) K range and suspended from a high stability thermal isolation system. During the mission we found that the resolution of the thermometers was degraded somewhat due to the impact of charged particles. This effect limited the useful resolution of the measurements to about two nanokelvins from the lambda point. The results reported here are limited to about ten nanokelvins from the transition.
Temperature characterisation of the CLOUD chamber at CERN
NASA Astrophysics Data System (ADS)
Dias, A. M.; Almeida, J.; Kirkby, J.; Mathot, S.; Onnela, A.; Vogel, A.; Ehrhart, S.
2014-12-01
Temperature stability, uniformity and absolute scale inside the CLOUD (Cosmics Leaving OUtdoor Droplets) chamber at CERN are important for experiments on aerosol particle nucleation and ice/liquid cloud formation. In order to measure the air temperature, a comprehensive set of arrays ("strings") of platinum resistance thermometers, thermocouples and optical sensors have been installed inside the 26 m3 chamber. The thermal sensors must meet several challenging design requirements: ultra-clean materials, 0.01 K measurement sensitivity, high absolute precision (<0.1 K), 200 K - 373 K range, ability to operate in high electric fields (20 kV/m), and fast response in air (~1 s) in order to measure rapid changes of temperature during ice/liquid cloud formation in the chamber by adiabatic pressure reductions. This presentation will focus on the design of the thermometer strings and the thermal performance of the chamber during the CLOUD8 and CLOUD9 campaigns, 2013-2014, together with the planned upgrades of the CLOUD thermal system.
A 6-bit 4 GS/s pseudo-thermometer segmented CMOS DAC
NASA Astrophysics Data System (ADS)
Yijun, Song; Wenyuan, Li
2014-06-01
A 6-bit 4 GS/s, high-speed and power-efficient DAC for ultra-high-speed transceivers in 60 GHz band millimeter wave technology is presented. A novel pseudo-thermometer architecture is proposed to realize a good compromise between the fast conversion speed and the chip area. Symmetrical and compact floor planning and layout techniques including tree-like routing, cross-quading and common-centroid method are adopted to guarantee the chip is fully functional up to near-Nyquist frequency in a standard 0.18 μm CMOS process. Post simulation results corroborate the feasibility of the designed DAC, which canperform good static and dynamic linearity without calibration. DNL errors and INL errors can be controlled within ±0.28 LSB and ±0.26 LSB, respectively. SFDR at 4 GHz clock frequency for a 1.9 GHz near-Nyquist sinusoidal output signal is 40.83 dB and the power dissipation is less than 37 mW.
Calibration of a Ti-in-muscovite geothermometer for ilmenite- and Al2SiO5-bearing metapelites
NASA Astrophysics Data System (ADS)
Wu, Chun-Ming; Chen, Hong-Xu
2015-01-01
The Ti-in-muscovite geothermometer was empirically calibrated as ln[T(oC)] = 7.258 + 0.289 ln(Ti) + 0.158[Mg/(Fe + Mg)] + 0.031 ln[P(kbar)] using ilmenite- and Al2SiO5-bearing assemblages in metapelites under P-T conditions of 450-800 °C and 0.1-1.4 GPa. The calibration was conducted for muscovites containing Ti = 0.01-0.07, Fe = 0.03-0.16, Mg = 0.01-0.32 and Mg/(Fe + Mg) = 0.05-0.73, respectively, on the basis of 11 oxygen per formula unit. Such compositional range covers more than 90% natural muscovites, and the random error of this thermometer is estimated to be of ± 65 °C. The geothermometer was validated against a set of independently determined temperature conditions between different degrees in samples from different prograde, inverted and contact metamorphic terranes. Application of this thermometer beyond the calibration conditions is not encouraged.
Structural disorder of graphite and implications for graphite thermometry
NASA Astrophysics Data System (ADS)
Kirilova, Martina; Toy, Virginia; Rooney, Jeremy S.; Giorgetti, Carolina; Gordon, Keith C.; Collettini, Cristiano; Takeshita, Toru
2018-02-01
Graphitization, or the progressive maturation of carbonaceous material, is considered an irreversible process. Thus, the degree of graphite crystallinity, or its structural order, has been calibrated as an indicator of the peak metamorphic temperatures experienced by the host rocks. However, discrepancies between temperatures indicated by graphite crystallinity versus other thermometers have been documented in deformed rocks. To examine the possibility of mechanical modifications of graphite structure and the potential impacts on graphite thermometry
, we performed laboratory deformation experiments. We sheared highly crystalline graphite powder at normal stresses of 5 and 25 megapascal (MPa) and aseismic velocities of 1, 10 and 100 µm s-1. The degree of structural order both in the starting and resulting materials was analyzed by Raman microspectroscopy. Our results demonstrate structural disorder of graphite, manifested as changes in the Raman spectra. Microstructural observations show that brittle processes caused the documented mechanical modifications of the aggregate graphite crystallinity. We conclude that the calibrated graphite thermometer
is ambiguous in active tectonic settings.
INTERNATIONAL REPORT: Revised Values for (t90 - t68) from 630°C to 1064°C
NASA Astrophysics Data System (ADS)
Rusby, R. L.; Hudson, R. P.; Durieux, M.
1994-01-01
A revised table of differences (t90 - t68) between values of temperature on the International Temperature Scale of 1990, ITS-90, and the corresponding values on the International Practical Temperature Scale of 1968, IPTS-68, is published at the request of the Comité Consultatif de Thermométrie (CCT). The revision affects only the range 630°C to 1064°C, where the IPTS-68 specified the use of platinum-10% rhodium versus platinum thermocouples. It follows from new intercomparisons of thermocouples carrying IPTS-68 calibrations with platinum resistance thermometers and radiation thermometers calibrated in accordance with the ITS-90. The largest change occurs at 760°C, where the difference formerly tabulated as 0,36°C is now 0,04°C. The revision concerns only the assessment of the differences between the ITS-90 and the IPTS-68, and does not affect the ITS-90 in any way.
Penn, Elizabeth Maggie
2014-01-01
This article presents a new model for scoring alternatives from “contest” outcomes. The model is a generalization of the method of paired comparison to accommodate comparisons between arbitrarily sized sets of alternatives in which outcomes are any division of a fixed prize. Our approach is also applicable to contests between varying quantities of alternatives. We prove that under a reasonable condition on the comparability of alternatives, there exists a unique collection of scores that produces accurate estimates of the overall performance of each alternative and satisfies a well-known axiom regarding choice probabilities. We apply the method to several problems in which varying choice sets and continuous outcomes may create problems for standard scoring methods. These problems include measuring centrality in network data and the scoring of political candidates via a “feeling thermometer.” In the latter case, we also use the method to uncover and solve a potential difficulty with common methods of rescaling thermometer data to account for issues of interpersonal comparability. PMID:24748759
NASA Astrophysics Data System (ADS)
Jin, Daeseong; Kim, Hackjin
2018-03-01
We have investigated the agglomeration of magnetite nanoparticles in the aqueous solution under magnetic field by measuring temporal change of magnetic weight. The magnetic weight corresponds to the force due to the magnetization of magnetic materials. Superparamagnetic magnetite nanoparticles are synthesized and used in this work. When the aqueous solution of magnetite nanoparticle is placed under magnetic field, the magnetic weight of the sample jumps instantaneously by Neel and Brown mechanisms and thereafter increases steadily following a stretched exponential function as the nanoparticles agglomerate, which results from the distribution of energy barriers involved in the dynamics. Thermal motions of nanoparticles in the agglomerate perturb the ordered structure of the agglomerate to reduce the magnetic weight. Fluctuation of the structural order of the agglomerate by temperature change is much faster than the formation of agglomerate and explained well with the Boltzmann distribution, which suggests that the magnetic weight of the agglomerate works as a magnetic thermometer.
Hopping conduction in zirconium oxynitrides thin film deposited by reactive magnetron sputtering
NASA Astrophysics Data System (ADS)
Guo, Jie; Zhan, Guanghui; Liu, Jingquan; Yang, Bin; Xu, Bin; Feng, Jie; Chen, Xiang; Yang, Chunsheng
2015-10-01
Zirconium oxynitrides thin film thermometers were demonstrated to be useful temperature sensors. However, the basic conduction mechanism of zirconium oxynitrides films has been a long-standing issue, which hinders the prediction and optimization of their ultimate performance. In this letter, zirconium oxynitrides films were grown on sapphire substrates by magnetron sputtering and their electric transport mechanism has been systemically investigated. It was found that in high temperatures region (>150 K) the electrical conductivity was dominated by thermal activation for all samples. In the low temperatures range, while Mott variable hopping conduction (VRH) was dominated the transport for films with relatively low resistance, a crossover from Mott VRH conduction to Efros-Shklovskii (ES) VRH was observed for films with relatively high resistance. This low temperature crossover from Mott to ES VRH indicates the presence of a Coulomb gap (~7 meV). These results demonstrate the competing and tunable conduction mechanism in zirconium oxynitrides thin films, which would be helpful for optimizing the performance of zirconium oxynitrides thermometer.
Comparison of Two Potassium-Filled Gas-Controlled Heat Pipes
NASA Astrophysics Data System (ADS)
Bertiglia, F.; Iacomini, L.; Moro, F.; Merlone, A.
2015-12-01
Calibration by comparison of platinum resistance thermometers and thermocouples requires transfer media capable of providing very good short-term temperature uniformity and temperature stability over a wide temperature range. This paper describes and compares the performance of two potassium-filled gas-controlled heat pipes (GCHP) for operation over the range from 420° C to 900° C. One of the heat pipes has been in operation for more than 10 years having been operated at temperature for thousands of hours, while the other was commissioned in 2010 following recently developed improvements to both the design, assembly, and filling processes. It was found that the two devices, despite differences in age, structure, number of wells, and filling processes, realized the same temperatures within the measurement uncertainty. The results show that the potassium-filled GCHP provides a durable and high-quality transfer medium for performing thermometer calibrations with very low uncertainties, over the difficult high-temperature range from 420° C to 900° C.
Collisional excitation of NH3 by atomic and molecular hydrogen
NASA Astrophysics Data System (ADS)
Bouhafs, N.; Rist, C.; Daniel, F.; Dumouchel, F.; Lique, F.; Wiesenfeld, L.; Faure, A.
2017-09-01
We report extensive theoretical calculations on the rotation-inversion excitation of interstellar ammonia (NH3) due to collisions with atomic and molecular hydrogen (both para- and ortho-H2). Close-coupling calculations are performed for total energies in the range 1-2000 cm-1 and rotational cross-sections are obtained for all transitions amongst the lowest 17 and 34 rotation-inversion levels of ortho- and para-NH3, respectively. Rate coefficients are deduced for kinetic temperatures up to 200 K. Propensity rules for the three colliding partners are discussed and we also compare the new results to previous calculations for the spherically symmetrical He and para-H2 projectiles. Significant differences are found between the different sets of calculations. Finally, we test the impact of the new rate coefficients on the calibration of the ammonia thermometer. We find that the calibration curve is only weakly sensitive to the colliding partner and we confirm that the ammonia thermometer is robust.
Pico-Kelvin thermometry and temperature stabilization using a resonant optical cavity.
Tan, Si; Wang, Suwen; Saraf, Shailendhar; Lipa, John A
2017-02-20
Ultra-high sensitivity temperature sensing and stable thermal control are crucial for many science experiments testing fundamental theories to high precision. Here we report the first pico-kevin scale thermometer operating at room temperature with an exceptionally low theoretical noise figure of ~70pK/Hz at 1 Hz and a high dynamic range of ~500 K. We have experimentally demonstrated a temperature sensitivity of <3.8nK/Hz at 1 Hz near room temperature, which is an order of magnitude improvement over the state of the art. We have also demonstrated an ultra-high stability thermal control system using this thermometer, achieving 3.7 nK stability at 1 s and ∼ 120 pK at 104 s, which is 10-100 times more stable than the state of the art. With some upgrades to this proof-of-principle device, we can expect it to be used for very high resolution tests of special relativity and in critical point phenomena.
Magnetic cooling for microkelvin nanoelectronics on a cryofree platform.
Palma, M; Maradan, D; Casparis, L; Liu, T-M; Froning, F N M; Zumbühl, D M
2017-04-01
We present a parallel network of 16 demagnetization refrigerators mounted on a cryofree dilution refrigerator aimed to cool nanoelectronic devices to sub-millikelvin temperatures. To measure the refrigerator temperature, the thermal motion of electrons in a Ag wire-thermalized by a spot-weld to one of the Cu nuclear refrigerators-is inductively picked-up by a superconducting gradiometer and amplified by a SQUID mounted at 4 K. The noise thermometer as well as other thermometers are used to characterize the performance of the system, finding magnetic field independent heat-leaks of a few nW/mol, cold times of several days below 1 mK, and a lowest temperature of 150 μK of one of the nuclear stages in a final field of 80 mT, close to the intrinsic SQUID noise of about 100 μK. A simple thermal model of the system capturing the nuclear refrigerator, heat leaks, and thermal and Korringa links describes the main features very well, including rather high refrigerator efficiencies typically above 80%.
Neonatal infrared axillary thermometry.
Seguin, J; Terry, K
1999-01-01
The authors compared axillary skin temperatures (AT) measured with an infrared (IR) thermometer (Lightouch Neonate, Exergen Corp) with rectal temperatures (RT) in 16 newly born term infants under radiant warmers (RW) and in cribs. Twelve stable, growing premature infants in incubators were also studied. This new device may be useful because of safety and rapid results (1 second), but clinical accuracy is unknown. For term infants, mean (SD) RT-AT difference was 0.1 (0.48) degree C under RW and 0.25 (0.17) degree C 2 hours later in cribs. For premature infants in incubators the mean RT-AT difference was 0.09 (0.16) degree C. Axillary temperatures measured by IR thermometer approximate RT for newly born term infants in cribs and stable premature infants in incubators. For newly born term infants under RW, RT-AT differences vary more widely, limiting clinical usefulness in this setting. The device, the unique age of this population, and the RW environment may play a role.
Irrigation scheduling based on crop canopy temperature for humid environments
USDA-ARS?s Scientific Manuscript database
The use of infrared thermometers (IR) to measure canopy temperatures for irrigation scheduling has been successfully applied in arid environments. Functionality of this technique in humid areas has been limited due to the presence of low vapor pressure deficits (VPD) and intermittent cloud cover. T...
In Vitro Determination of the Accuracy and Precision of an Infrared Tympanic Thermometer
1991-05-01
type G.23, Standard Telephone Co. Ltd.). Measurements were made in 18 subjects; four were febrile . The investigators induced changes of central...contraindications (e.g. neutropenia , rectal surgery, increased intracranial pressure, ischemic chest pain); and, (d) there is the potential for cross
NASA Astrophysics Data System (ADS)
Cherniak, D. J.; Manchester, J.; Watson, E. B.
2007-09-01
Chemical diffusion of Zr and Hf under anhydrous conditions has been measured in synthetic and natural rutile. The sources of diffusant used were hafnon or zircon powders or a hafnon-rutile mixture. Experiments were run in crimped Pt capsules in air, or in sealed silica glass capsules with solid buffers (to buffer at NNO or QFM). Rutherford Backscattering Spectrometry (RBS) was used to measure Zr and Hf diffusion profiles. From these measurements, the following Arrhenius relations were obtained: For Zr diffusion parallel to c, over the temperature range 750-1100 °C DZr¦c = 9.8 × 10 - 15 exp(- 170 ± 30 kJ mol - 1 /RT) m 2 s - 1 For Hf diffusion parallel to c, over the temperature range 800-1000 °C DHf¦c = 9.1 × 10 - 15 exp(- 169 ± 36 kJ mol - 1 /RT) m 2 s - 1 For Hf diffusion normal to c, over the temperature range 750-1050 °C DHf⊥c = 2.5 × 10 - 12 exp(- 227 ± 62 kJ mol - 1 /RT) m 2 s - 1 . Diffusivities for experiments buffered at QFM and NNO are similar to those run in air. Diffusivities in synthetic and natural rutile are likewise similar, indicating that these findings can be applied directly in determining Zr diffusivities in rutile in natural systems. These data indicate that rutile should be moderately retentive of Zr chemical signatures, with Zr diffusivities within an order of magnitude of those for Pb in rutile over most geologic conditions. When applied in evaluation of the relative robustness of the recently developed Zr-in-rutile geothermometer [T. Zack, R. Moraes, A. Kronz, Temperature dependence of Zr in rutile: empirical calibration of a rutile thermometer, Contributions to Mineralogy and Petrology 148 (2004) 471-488., E.B. Watson, D.A. Wark, J.B. Thomas, Crystallization thermometers for zircon and rutile, Contributions to Mineralogy and Petrology 151 (2006) 413-433.], these findings suggest that Zr concentrations in rutile will be somewhat more likely to be affected by later thermal disturbance than the geothermometer based on Zr concentrations in titanite [L. Hayden, E.B.Watson, D.A. Wark, A thermobarometer for sphene, Abstract, 16th V.M. Goldschmidt Conference (2006).], and much less resistant to diffusional alteration subsequent to crystallization than the Ti-in-zircon geothermometer [E.B. Watson, D.A. Wark, J.B. Thomas, Crystallization thermometers for zircon and rutile, Contributions to Mineralogy and Petrology 151 (2006) 413-433., E.B.Watson, T.M.Harrison, Zircon thermometer reveals minimum melting conditions on earliest Earth, Science 308 (2005) 841-844.].
Thomas Clifford Allbutt and Comparative Pathology
ERIC Educational Resources Information Center
Leung, Danny C. K.
2008-01-01
This paper reconceptualizes Thomas Clifford Allbutt's contributions to the making of scientific medicine in late nineteenth-century England. Existing literature on Allbutt usually describes his achievements, such as his design of the pocket thermometer and his advocacy of the use of the ophthalmoscope in general medicine, as independent events;…
Articulated Multimedia Physics, Lesson 13, Internal Energy, Heat, and Temperature.
ERIC Educational Resources Information Center
New York Inst. of Tech., Old Westbury.
As the thirteenth lesson of the Articulated Multimedia Physics Course, instructional materials are presented in this study guide with relation to internal energy, heat, and temperature. The topics are concerned with collisions, thermometers, friction forces, degrees Centigrade and Fahrenheit, calories, Brownian motion, and state changes. The…
Low Temperature Thermometry Using Inexpensive Silicon Diodes.
ERIC Educational Resources Information Center
Waltham, N. R.; And Others
1981-01-01
Describes the use of silicon diodes for low temperature thermometry in the teaching laboratory. A simple and inexpensive circuit for display of the diode forward voltage under constant current conditions is described, and its application in the evaluation of low cost silicon diodes as low temperature thermometers is presented. (SK)
Resistance Probes in the Science Laboratory Part I. The Thermistor Thermometer.
ERIC Educational Resources Information Center
Powers, Michael H.
1987-01-01
Describes the functioning of temperature transducers, or thermistors. Discusses the interface connections between thermistors and the game-port of several kinds of microcomputers. Demonstrates how to construct a thermistor probe and suggests several applications of the use of such probes in various scientific experiments. (TW)
Enlivening Physics, a Local Video Disc Project.
ERIC Educational Resources Information Center
McInerney, M.
1989-01-01
Describes how to make and use an inexpensive video disc of physics demonstrations. Discusses the background, production of the disc, subject of the disc including angular momentum, "monkey and the hunter" experiment, Doppler shift, pressure of a constant volume of gas thermometer, and wave effects, and using the disc in classroom. (YP)
Studying the Greenhouse Effect: A Simple Demonstration.
ERIC Educational Resources Information Center
Papageorgiou, G.; Ouzounis, K.
2000-01-01
Studies the parameters involved in a presentation of the greenhouse effect and describes a simple demonstration of this effect. Required equipment includes a 100-120 watt lamp, a 250mL beaker, and a thermometer capable of recording 0-750 degrees Celsius together with a small amount of chloroform. (Author/SAH)
46 CFR 98.25-40 - Valves, fittings, and accessories.
Code of Federal Regulations, 2013 CFR
2013-10-01
... located at the highest practical point. The thermometer well shall terminate in the liquid space and be... and discharge liquid and vapor shut-off valves, safety relief valves, liquid level gaging devices... to the tanks, except safety devices and liquid level gaging devices, shall have manually operated...
46 CFR 98.25-40 - Valves, fittings, and accessories.
Code of Federal Regulations, 2012 CFR
2012-10-01
... located at the highest practical point. The thermometer well shall terminate in the liquid space and be... and discharge liquid and vapor shut-off valves, safety relief valves, liquid level gaging devices... to the tanks, except safety devices and liquid level gaging devices, shall have manually operated...
46 CFR 98.25-40 - Valves, fittings, and accessories.
Code of Federal Regulations, 2011 CFR
2011-10-01
... located at the highest practical point. The thermometer well shall terminate in the liquid space and be... and discharge liquid and vapor shut-off valves, safety relief valves, liquid level gaging devices... to the tanks, except safety devices and liquid level gaging devices, shall have manually operated...
46 CFR 98.25-40 - Valves, fittings, and accessories.
Code of Federal Regulations, 2014 CFR
2014-10-01
... located at the highest practical point. The thermometer well shall terminate in the liquid space and be... and discharge liquid and vapor shut-off valves, safety relief valves, liquid level gaging devices... to the tanks, except safety devices and liquid level gaging devices, shall have manually operated...
Lian, Xiusheng; Zhao, Dian; Cui, Yuanjing; Yang, Yu; Qian, Guodong
2015-12-28
A near infrared pumped luminescent metal-organic framework thermometer Nd(0.577)Yb(0.423)BDC-F4, with near infrared fluorescence and excellent sensitivity in the physiological temperature range (293-313 K), has been first realized, and might be potentially applied for biomedical systems.
Let's Repair the Broken Galileo Thermometer
ERIC Educational Resources Information Center
Kireš, Marián
2018-01-01
We have developed and verified laboratory work as guided inquiry for upper secondary level students, focusing on conceptual understanding of the physical principle that forms the basis of temperature measurement, and on improvement of selected skills. Conceptual pre-test questions initiate the students' interest and help identify input…
Implantable, Ingestible Electronic Thermometer
NASA Technical Reports Server (NTRS)
Kleinberg, Leonard
1987-01-01
Small quartz-crystal-controlled oscillator swallowed or surgically implanted provides continuous monitoring of patient's internal temperature. Receiver placed near patient measures oscillator frequency, and temperature inferred from previously determined variation of frequency with temperature. Frequency of crystal-controlled oscillator varies with temperature. Circuit made very small and implanted or ingested to measure internal body temperature.
Astronaut Alan B. Shepard has his blood pressure and temperature checked
NASA Technical Reports Server (NTRS)
1961-01-01
Astronaut Alan B. Shepard has a thermometer in his mouth to check his temperature checked prior to his Mercury-Redstone 3 (MR-3) mission, the first American manned suborbital space flight (02739); Shepard has his heart rate checked. The attending physician is Dr. William K. Douglas (02740).
outbreak total has reached 36 cases, 14 confirmed and 22 suspected. Thermometer in the sun Study finds Ebola cases in DRC, 27 deaths Stephanie Soucheray | May 23, 2018 With worries about the disease newly pledged for an outbreak that has grown to 51 total cases, 28 confirmed. More news Inside CIDRAP
The Thermal History of Enstatite Chondrites
NASA Astrophysics Data System (ADS)
Zhang, Y.; Benoit, P. H.; Sears, D. W. G.
1992-07-01
In an attempt to decipher the complicated thermal history of the enstatite chondrites, the CaS enstatite (Larimer and Buseck, 1974; Fogel et al., 1989), cubic sulfide (Skinner and Luce, 1971) and sphalerite (Kissin, 1989; El Goresy and Ehlers, 1989) systems have been applied, but the results have not been straightforward. The CaS-En thermometer gives metamorphic temperatures which appear reasonable, but which do not correlate well with petrologic type. The cubic sulfides yield reasonable temperatures for the EH chondrites, but the values for EL chondrites are very low. To some extent, the problem has been the lack of low petrologic type EL chondrites. Here we discuss data for the recently discovered EL3 chondrites (Chang et al., 1992) and we examine the applicability of the Fe-Ni-P system for thermometry. The CaS-En thermometer uses three reactions including equilibria between metal, CaS, SiO2, enstatite and FeS. The method is crucially dependent on the activity coefficients for Si and CaSiO3 which are in solid solutions with metal and enstatite, respectively. The cubic sulfide thermometer uses the solubility of FeS in MgS and MnS, while the ZnS thermometer (which is pressure-dependent) uses the solubility of FeS in ZnS. Current equilibration temperature estimates for enstatite chondrites including the EL3 chondrites are listed in Table 1. Table 1. Estimates of equilibration temperatures (degrees C) for enstatite chondrites.* Petrologic type EH EL System 3 4 5 6 3 4 5 6 En-CaS 1030 950 830 - 830 - - 1025 Cubic sulf 400 680 600 - <<400 - - <400 ZnS 410 (1859)+ - - 500 - - 550 Fe-Ni-P <450 500 550 - <<450 - - <450 *Literature data (see text), present data (bold type). +Heavily shocked. In an attempt to use the Fe-Ni-P system as a thermometer for enstatite chondrites, we used the phase diagram of Doan and Goldstein (1970). Like the other systems, this required extrapolation to lower temperatures (Fig. 1). The temperatures calculated from this system mirror those of the sulfides, suggesting major differences in the thermal history of the EL and EH chondrites. Two points may be made from the data in Table 1. The EH3 and EL3 chondrites have similar En-CaS equilibration temperatures to those of the higher petrologic types which we suspect reflect pre-metamorphic equilibria. Second, both the cubic sulfides and the phosphides yield metamorphic temperatures for the EH chondrites which are similar to those for ordinary chondrites, while EL chondrites yield very low temperatures. The EL chondrite parent body must have cooled at especially slow rates, perhaps because it was much larger than the EH parent body, or maybe the cooling rate on EL body was governed by the attenuation of the heat source rather than burial depth. Chang Y., Benoit P.H. and Sears D.W.G. (1992) Lunar and Planet. Sci. 23, 217-218. Doan A.S. and Goldstein J.I. (1970) Met. Trans. 1, 1759-1767. El Goresy A. and Ehlers K (1989) Geochim. Cosmochim. Acta 53, 1657-1668. Fogel R.A., Hess P.C. and Rutherford M.C. (1989) Geochim. Cosmochim. Acta 53, 2735-2746. Kissin S.A.(1989) Geochim. Cosmochim. Acta 53, 1649-1655. Larimer J.W. and Buseck P.R. (1974) Geochim. Cosmochim. Acta 38, 471-477. Skinner B.J. and Luce F.D. (1971) Amer. Min. 56, 1269-1296. Figure 1, which in the hard copy appears here, shows isotherm from the Fe-Ni-P phase diagram with data for enstatite chondrites superimposed.
Greenhouse Effect in the Classroom: A Project- and Laboratory-Based Curriculum.
ERIC Educational Resources Information Center
Lueddecke, Susann B.; Pinter, Nicholas; McManus, Scott A.
2001-01-01
Tests a multifaceted curriculum for use in introductory earth science classes from the secondary school to the introductory undergraduate level. Simulates the greenhouse effect with two fish tanks, heat lamps, and thermometers. Uses a hands-on science approach to develop a deeper understanding of the climate system among students. (Contains 28…
Assessment of Selected Lighter-Than-Air Vehicles for Mission Tasks of the U.S. Coast Guard
1978-05-01
this analysis assumed that the LTA would be performing a primary mission of, perhaps, IELT or MEP, and evaluated it in a secondary SAR role...Patrol (IIP); the Airborne Radiation Thermometer (ART) surveys; and miscellaneous support on specific tasks for government agencies and academic
USDA-ARS?s Scientific Manuscript database
Remotely-sensed canopy temperature from infrared thermometer (IRT) sensors has long been shown to be effective for detecting plant water stress. To help alleviate water shortage, a field study was conducted at the USDA-ARS San Joaquin Valley Agricultural Sciences Center in Parlier, California USA to...
Water-Cooled Optical Thermometer
NASA Technical Reports Server (NTRS)
Menna, A. A.
1987-01-01
Water-cooled optical probe measures temperature of nearby radiating object. Intended primarily for use in silicon-growing furnace for measuring and controlling temperatures of silicon ribbon, meniscus, cartridge surfaces, heaters, or other parts. Cooling water and flushing gas cool fiber-optic probe and keep it clean. Fiber passes thermal radiation from observed surface to measuring instrument.
Fiber-optic temperature probe system for inner body
NASA Astrophysics Data System (ADS)
Liu, Bo; Deng, Xing-Zhong; Cao, Wei; Cheng, Xianping; Xie, Tuqiang; Zhong, Zugen
1991-08-01
The authors have designed a fiber-optic temperature probe system that can quickly insert its probe into bodies to measure temperature. Its thermometer unit has the function of program- controlled zeroing. The single-chip microcomputer is used to control the whole system and process data. The sample system has been tested in a coal furnace.
2008-12-12
socioeconomic affairs, and politics were little more than a vehicle for ruling classes to compete among themselves for political power. President William...British provinces of Kenya and Rhodesia. He targeted railways, infrastructure, and lines of communications. 82 Birtle, U.S. Army Counterinsurgency
Fast Quasi-Adiabatic Gas Cooling: An Experiment Revisited
ERIC Educational Resources Information Center
Oss, S.; Gratton, L. M.; Calza, G.; Lopez-Arias, T.
2012-01-01
The well-known experiment of the rapid expansion and cooling of the air contained in a bottle is performed with a rapidly responsive, yet very cheap thermometer. The adiabatic, low temperature limit is approached quite closely and measured with our apparatus. A straightforward theoretical model for this process is also presented and discussed.…
Heat Loss Experiments: Teach Energy Savings with Cardboard "House"
ERIC Educational Resources Information Center
Roman, Harry T.
2011-01-01
Using two cardboard boxes, a light bulb socket, light bulbs of varying wattage, a thermometer, and some insulation, students can learn some interesting lessons about how heat loss occurs in homes. This article describes practical experiments that work well on units related to energy, sustainable energy, renewables, engineering, and construction.…
FIRST FLOOR, A view looking north at the controls for ...
FIRST FLOOR, A view looking north at the controls for the Stokes Press along the wall outside Room 136. These controls include a thermometer, timer and pressure switches, and a buss bar used for static electricity control - Department of Energy, Mound Facility, Isolated Building (I Building), One Mound Road, Miamisburg, Montgomery County, OH
It's Too Hot! It's Too Cold!--Understanding How Heat Works
ERIC Educational Resources Information Center
Roman, Harry T.
2012-01-01
Engineers often measure temperature for a wide variety of applications and assessments. This article describes how STEM educators can use thermometers or temperature sensors to help students understand how heat disperses through fluids, both air and water. It also provides hands-on learning about air and water heating systems. (Contains 4 figures.)
27 CFR 30.22 - Hydrometers and thermometers.
Code of Federal Regulations, 2013 CFR
2013-04-01
... subdivisions of degrees as follows: Type Range Subdivision Pencil type 10° to 100° 1° V-back 10° to 100° 1° Glass shell (earlier model) 40° to 100° 1/2° Glass shell (later model) 40° to 100° 1/4° (Sec. 201, Pub...
27 CFR 30.22 - Hydrometers and thermometers.
Code of Federal Regulations, 2012 CFR
2012-04-01
... subdivisions of degrees as follows: Type Range Subdivision Pencil type 10° to 100° 1° V-back 10° to 100° 1° Glass shell (earlier model) 40° to 100° 1/2° Glass shell (later model) 40° to 100° 1/4° (Sec. 201, Pub...
27 CFR 30.22 - Hydrometers and thermometers.
Code of Federal Regulations, 2014 CFR
2014-04-01
... subdivisions of degrees as follows: Type Range Subdivision Pencil type 10° to 100° 1° V-back 10° to 100° 1° Glass shell (earlier model) 40° to 100° 1/2° Glass shell (later model) 40° to 100° 1/4° (Sec. 201, Pub...
Sediment temperature was measured using submersible Onset TidbiT® recording thermistor thermometers at eelgrass (Zostera marina, Z. japonica) mid-rhizome root depth (~5 cm) at 6 stations on a transect from ~MLLW (mean lower low water) at the channel edge to near MHHW (mean higher...
Weather. Third Grade. Revised. Anchorage School District Elementary Science Program.
ERIC Educational Resources Information Center
Defendorf, Jean, Ed.
This resource book introduces third-grade children to the environment by studying the weather and its effects. Lessons are provided including: (1) constructing a weather diary; (2) thermometers; (3) clouds; (4) barometric pressure; (5) wind vanes; (6) heating and cooling air; and (7) analyzing weather data. Each lesson includes a listing of…
Integration of wireless sensor networks into automatic irrigation scheduling of a center pivot
USDA-ARS?s Scientific Manuscript database
A six-span center pivot system was used as a platform for testing two wireless sensor networks (WSN) of infrared thermometers. The cropped field was a semi-circle, divided into six pie shaped sections of which three were irrigated manually and three were irrigated automatically based on the time tem...
Vocational-Technical Physics Project. Instructor's Manual. Field Test Edition.
ERIC Educational Resources Information Center
Forsyth Technical Inst., Winston-Salem, NC.
This instructor's manual in vocational physics consists of five modules: Jacks, Thermometers, The Alternator, The Pool Table, and The Radiator. It is an individualized approach, designed for use with accompanying student manuals on each of the individual modules. Each module in the instructor's manual consists of a general description plus an…
Temperature Scales: Celsius, Fahrenheit, Kelvin, Reamur, and Romer.
ERIC Educational Resources Information Center
Romer, Robert H.
1982-01-01
Traces the history and development of temperature scales which began with the 17th-century invention of the liquid-in-glass thermometer. Focuses on the work of Olaf Romer, Daniel Fahrenheit, Rene-Antoine de Reamur, Anders Celsius, and William Thomson (Lord Kelvin). Includes experimental work and consideration of high/low fixed points on the…
Method to determine thermal profiles of nanoscale circuitry
Zettl, Alexander K; Begtrup, Gavi E
2013-04-30
A platform that can measure the thermal profiles of devices with nanoscale resolution has been developed. The system measures the local temperature by using an array of nanoscale thermometers. This process can be observed in real time using a high resolution imagining technique such as electron microscopy. The platform can operate at extremely high temperatures.
USDA-ARS?s Scientific Manuscript database
The objectives of this study were to characterize wireless sensor nodes that we developed in terms of power consumption and functionality, and compare the performance of mesh and non-mesh wireless sensor networks (WSNs) comprised mainly of infrared thermometer thermocouples located on a center pivot...
Agreement between auricular and rectal measurements of body temperature in healthy cats.
Sousa, Marlos G; Carareto, Roberta; Pereira-Junior, Valdo A; Aquino, Monally C C
2013-04-01
Measurement of body temperature is a routine part of the clinical assessment of a patient. However, this procedure may be time-consuming and stressful to most animals because the standard site of temperature acquisition remains the rectal mucosa. Although an increasing number of clinicians have been using auricular temperature to estimate core body temperature, evidence is still lacking regarding agreement between these two methods in cats. In this investigation, we evaluated the agreement between temperatures measured in the rectum and ear in 29 healthy cats over a 2-week period. Temperatures were measured in the rectum (using digital and mercury-in-glass thermometers) and ear once a day for 14 consecutive days, producing 406 temperature readings for each thermometer. Mean temperature and confidence intervals were similar between methods, and Bland-Altman plots showed small biases and narrow limits of agreement acceptable for clinical purposes. The interobserver variability was also checked, which indicated a strong correlation between two near-simultaneous temperature readings. Results are consistent with auricular thermometry being a reliable alternative to rectal thermometry for assessing core body temperature in healthy cats.
Investigation of the Behavior of the Co C Eutectic Fixed Point
NASA Astrophysics Data System (ADS)
Girard, F.; Battuello, M.; Florio, M.
2007-12-01
The behavior of the Co C eutectic fixed point was investigated at INRIM. Several cells of different design and volume, and filled with cobalt of different purity were constructed and investigated with both Pt/Pd thermocouples and radiation thermometers. The melting behavior was investigated with respect to the melting rate, the pre-freezing rate, and the annealing time. The melting temperatures, as defined, were not significantly affected by the different testing conditions, even if the shape and duration of the plateaux were influenced. Several tens of melt and freeze cycles were performed with the different cells. The spread in the results for all of the different conditions was very limited in extent, giving rise to a standard deviation of less than 0.04 °C; a repeatability of better than 0.02 °C was found with both Pt/Pd thermocouples and radiation thermometers. The results of our measurements are encouraging and confirm the suitability of Co C as a reference point for the high-temperature range in a possible future temperature scale. Investigations of long-term stability remain ongoing.
NASA Astrophysics Data System (ADS)
Du, Zhongzhou; Sun, Yi; Liu, Jie; Su, Rijian; Yang, Ming; Li, Nana; Gan, Yong; Ye, Na
2018-04-01
Magnetic fluid hyperthermia, as a novel cancer treatment, requires precise temperature control at 315 K-319 K (42 °C-46 °C). However, the traditional temperature measurement method cannot obtain the real-time temperature in vivo, resulting in a lack of temperature feedback during the heating process. In this study, the feasibility of temperature measurement and feedback control using magnetic nanoparticles is proposed and demonstrated. This technique could be applied in hyperthermia. Specifically, the triangular-wave temperature measurement method is improved by reconstructing the original magnetization response of magnetic nanoparticles based on a digital phase-sensitive detection algorithm. The standard deviation of the temperature in the magnetic nanoparticle thermometer is about 0.1256 K. In experiments, the temperature fluctuation of the temperature measurement and feedback control system using magnetic nanoparticles is less than 0.5 K at the expected temperature of 315 K. This shows the feasibility of the temperature measurement method for temperature control. The method provides a new solution for temperature measurement and feedback control in hyperthermia.
Electronic clinical predictive thermometer using logarithm for temperature prediction
NASA Technical Reports Server (NTRS)
Cambridge, Vivien J. (Inventor); Koger, Thomas L. (Inventor); Nail, William L. (Inventor); Diaz, Patrick (Inventor)
1998-01-01
A thermometer that rapidly predicts body temperature based on the temperature signals received from a temperature sensing probe when it comes into contact with the body. The logarithms of the differences between the temperature signals in a selected time frame are determined. A line is fit through the logarithms and the slope of the line is used as a system time constant in predicting the final temperature of the body. The time constant in conjunction with predetermined additional constants are used to compute the predicted temperature. Data quality in the time frame is monitored and if unacceptable, a different time frame of temperature signals is selected for use in prediction. The processor switches to a monitor mode if data quality over a limited number of time frames is unacceptable. Determining the start time on which the measurement time frame for prediction is based is performed by summing the second derivatives of temperature signals over time frames. When the sum of second derivatives in a particular time frame exceeds a threshold, the start time is established.
Proof of concept: temperature sensing waders for environmental sciences
NASA Astrophysics Data System (ADS)
Hut, R.; Tyler, S.; van Emmerik, T.
2015-12-01
A prototype temperature sensing pair of waders is introduced and tested. The water temperature at the stream-bed is interesting both for scientist studying the hyporheic zone as well as for, e.g., fishers spotting good fishing locations. A temperature sensor incorporated in waders worn by members of the public can give scientists an additional source of information on streamwater-groundwater interaction. A pair of waders was equipped with a thermistor and calibrated in the lab. Tests with both the waders and a reference thermometer in a deep polder ditch with a known localized groundwater contribution (i.e. boil) showed that the temperature sensing waders are capable of identifying the boil location. However, the temperature sensing waders showed a less pronounced response to changing water temperature compared to the reference thermometer, most likely due to the heat capacity of the person in the waders. This research showed that data from temperature sensing waders worn by the public and shared with scientists can be used by to decide where the most interesting places are to do more detailed and more expensive, research.
Proof of concept: temperature-sensing waders for environmental sciences
NASA Astrophysics Data System (ADS)
Hut, Rolf; Tyler, Scott; van Emmerik, Tim
2016-02-01
A prototype temperature-sensing pair of waders is introduced and tested. The water temperature at the streambed is interesting both for scientists studying the hyporheic zone and for, e.g., fishers spotting good fishing locations. A temperature sensor incorporated into waders worn by members of the public can give scientists an additional source of information on stream-water-groundwater interaction. A pair of waders was equipped with a thermistor and calibrated in the lab. Tests with both the waders and a reference thermometer in a deep polder ditch with a known localized groundwater contribution (i.e., boil) showed that the temperature-sensing waders are capable of identifying the boil location. However, the temperature-sensing waders showed a less pronounced response to changing water temperature compared to the reference thermometer, most likely due to the heat capacity of the person in the waders. This research showed that data from temperature-sensing waders worn by the public and shared with scientists can be used to decide where the most interesting places are to do more detailed and more expensive research.
Determining the Leaf Emissivity of Three Crops by Infrared Thermometry
Chen, Chiachung
2015-01-01
Plant temperature can provide important physiological information for crop management. Non-contact measurement with an infrared thermometer is useful for detecting leaf temperatures. In this study, a novel technique was developed to measure leaf emissivity using an infrared thermometer with an infrared sensor and a thermocouple wire. The measured values were transformed into true temperatures by calibration equations to improve the measurement accuracy. The relationship between two kinds of measurement temperatures and setting emissivities was derived as a model for calculating of true emissivity. The emissivities of leaves of three crops were calculated by the mathematical equation developed in this study. The mean emissivities were 0.9809, 0.9783, 0.981 and 0.9848 for Phalaenopsis mature and new leaves and Paphiopedilum and Malabar chestnut leaves, respectively. Emissivity differed significantly between leaves of Malabar chestnut and the two orchids. The range of emissivities determined in this study was similar to that in the literature. The precision of the measurement is acceptable. The method developed in this study is a real-time, in situ technique and could be used for agricultural and forestry plants. PMID:25988870
NASA Technical Reports Server (NTRS)
Ramesham, Rajeshuni; Maki, Justin N.; Cucullu, Gordon C.
2008-01-01
Package Qualification and Verification (PQV) of advanced electronic packaging and interconnect technologies and various other types of qualification hardware for the Mars Exploration Rover/Mars Science Laboratory flight projects has been performed to enhance the mission assurance. The qualification of hardware (Engineering Camera and Platinum Resistance Thermometer, PRT) under extreme cold temperatures has been performed with reference to various project requirements. The flight-like packages, sensors, and subassemblies have been selected for the study to survive three times (3x) the total number of expected temperature cycles resulting from all environmental and operational exposures occurring over the life of the flight hardware including all relevant manufacturing, ground operations and mission phases. Qualification has been performed by subjecting above flight-like qual hardware to the environmental temperature extremes and assessing any structural failures or degradation in electrical performance due to either overstress or thermal cycle fatigue. Experiments of flight like hardware qualification test results have been described in this paper.
NASA Astrophysics Data System (ADS)
Liedberg, Hans; Kebede Ejigu, Efrem; Madiba, Tshifhiwa; du Clou, Sven; Chibaya, Blessing; Mwazi, Victor; Kajane, Tebogo; Mundembe, Victor; Kwong, Christian Ng Ha; Madeleine, Gilbert
2017-01-01
A Regional Metrology Organization (RMO) supplementary comparison of liquid in glass thermometer (AFRIMETS.T-S5) was carried out by the National Metrology Institute of South Africa (NMISA), Zimbabwe Scientific & Industrial Research & Development Centre—National Metrology Institute (SIRDC-NMI), Zambia Bureau of Standards (ZABS), Botswana Bureau of Standards (BOBS), Namibian Standards Institute (NSI), Mauritius Standards Bureau (MSB) and Seychelles Bureau of Standards (SBS) between January and September 2016. The temperature range of the inter comparison is -35 °C to 250 °C. The results of this comparison are reported here, along with descriptions of the Artefacts used. This report also presents the uncertainty budget of each participant. The results are analysed and normalized error (En) values are reported. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Rizzo, Maria; Arfuso, Francesca; Alberghina, Daniela; Giudice, Elisabetta; Gianesella, Matteo; Piccione, Giuseppe
2017-10-01
The aim of this study was to evaluate the influence of moderate treadmill exercise session on body surface and core temperature in dog measured by means of two infrared instruments. Ten Jack Russell Terrier/Miniature Pinscher mixed-breed dogs were subjected to 15min of walking, 10min of trotting and 10min of gallop. At every step, body surface temperature (T surface ) was measured on seven regions (neck, shoulder, ribs, flank, back, internal thigh and eye) using two different methods, a digital infrared camera (ThermaCam P25) and a non-contact infrared thermometer (Infrared Thermometer THM010-VT001). Rectal temperature (T rectal ) and blood samples were collected before (T0) and after exercise (T3). Blood samples were tested for red blood cell (RBC), hemoglobin concentration (Hb) and hematocrit (Hct). A significant effect of exercise in all body surface regions was found, as measured by both infrared methods. The temperature obtained in the eye and the thigh area were higher with respect to the other studied regions throughout the experimental period (P<0.0001). RBC, Hb, Hct and T rectal values were higher at T3 (P<0.05). Statistically significant higher temperature values measured by infrared thermometer was found in neck, shoulder, ribs, flank, back regions respect to the values obtained by digital infrared camera (P<0.0001). The results obtained in this study showed that both internal and surface temperatures are influenced by physical exercise probably due to muscle activity and changes in blood flow in dogs. Both infrared instruments used in this study have proven to be useful in detecting surface temperature variations of specific body regions, however factors including type and color of animal hair coat must be taken into account in the interpretation of data obtained by thermography methodology. Copyright © 2017 Elsevier Ltd. All rights reserved.
Lazenby, Mark; Dixon, Jane; Bai, Mei; McCorkle, Ruth
2014-02-01
Distress screening guidelines call for rapid screening for emotional distress at the time of cancer diagnosis. The purpose of this study was to examine the distress thermometer's (DT) ability to screen in patients in treatment for advanced cancer who may be depressed. Using cross-sectional data collected from patients within 30 days of diagnosis with advanced cancer, this study used ROC analysis to determine the optimal-cutoff point of the distress thermometer (DT) for screening for depression as measured by the physician health questionnaire (PHQ)-9; inter-test reliability analysis to compare the DT with the PHQ-2 for screening in possible cases of depression, and multivariate analysis to examine associations among the DT emotional problem list (EPL) items with cases of depression. The average age of the 123 patients in the study was 59.9 (12.9) years. Seventy (56.9%) were female. All had Stage 3 or 4 cancers (40% gastrointestinal, 19% gynecologic, 20% head and neck, 21% lung). The mean DT score was 4 (2.7)/10; and 56 (43%) were depressed as measured by the PHQ-9 ≥ 5. The optimal DT cut-off score to screen in possible cases of depression was ≥ 2/10, with a sensitivity of .96, compared to a sensitivity of .32 of the PHQ-2 ≥ 2. Correlation coefficients for the DT ≥ 2 and the PHQ-2 with the PHQ-9 ≥ 5 were 0.4 and -0.2, respectively. EPL items associated with cases of depression were Depression (OR = 0.15, 0.02-0.85) and Sadness (OR = 0.21, 0.06-0.72). The optimal DT threshold for identifying possible cases of depression at the time of diagnosis is ≥ 2; this threshold is more sensitive than the PHQ-2 ≥ 2. EPL items may be used with the DT score to triage patients for evaluation.
X-Ray Calorimeter Arrays for Astrophysics
NASA Technical Reports Server (NTRS)
Kilbourne, Caroline A.
2009-01-01
High-resolution x-ray spectroscopy is a powerful tool for studying the evolving universe. The grating spectrometers on the XMM and Chandra satellites started a new era in x-ray astronomy, but there remains a need for instrumentation that can provide higher spectral resolution with high throughput in the Fe-K band (around 6 keV) and can enable imaging spectroscopy of extended sources, such as supernova remnants and galaxy clusters. The instrumentation needed is a broad-band imaging spectrometer - basically an x-ray camera that can distinguish tens of thousands of x-ray colors. The potential benefits to astrophysics of using a low-temperature calorimeter to determine the energy of an incident x-ray photon via measurement of a small change in temperature was first articulated by S. H. Moseley over two decades ago. In the time since, technological progress has been steady, though full realization in an orbiting x-ray telescope is still awaited. A low-temperature calorimeter can be characterized by the type of thermometer it uses, and three types presently dominate the field. The first two types are temperature-sensitive resistors - semiconductors in the metal-insulator transition and superconductors operated in the superconducting-normal transition. The third type uses a paramagnetic thermometer. These types can be considered the three generations of x-ray calorimeters; by now each has demonstrated a resolving power of 2000 at 6 keV, but only a semiconductor calorimeter system has been developed to spaceflight readiness. The Soft X-ray Spectrometer on Astro-H, expected to launch in 2013, will use an array of silicon thermistors with I-IgTe x-ray absorbers that will operate at 50 mK. Both the semiconductor and superconductor calorimeters have been implemented in small arrays, kilo-pixel arrays of the superconducting calorimeters are just now being produced, and it is anticipated that much larger arrays will require the non-dissipative advantage of magnetic thermometers.
Baxter, Ruth; Taylor, Natalie; Kellar, Ian; Pye, Victoria; Mohammed, Mohammed A; Lawton, Rebecca
2018-02-16
The positive deviance approach seeks to identify and learn from exceptional performers. Although a framework exists to apply positive deviance within healthcare organisations, there is limited guidance to support its implementation. The approach has also rarely explored exceptional performance on broad outcomes, been implemented at ward level, or applied within the UK. This study develops and critically appraises a pragmatic method for identifying positively deviant wards using a routinely collected, broad measure of patient safety. A two-phased observational study was conducted. During phase 1, cross-sectional and temporal analyses of Safety Thermometer data were conducted to identify a discrete group of positively deviant wards that consistently demonstrated exceptional levels of safety. A group of matched comparison wards with above average performances were also identified. During phase 2, multidisciplinary staff and patients on the positively deviant and comparison wards completed surveys to explore whether their perceptions of safety supported the identification of positively deviant wards. 34 elderly medical wards within a northern region of England, UK. Multidisciplinary staff (n=161) and patients (n=188) clustered within nine positively deviant and comparison wards. Phase 1: A combination of analyses identified five positively deviant wards that performed best in the region, outperformed their organisation and performed consistently well over 12 months. Five above average matched comparator wards were also identified. Phase 2: Staff and patient perceptions of safety generally supported the identification of positively deviant wards using Safety Thermometer data, although patient perceptions of safety were less concordant with the routinely collected data. This study tentatively supports a pragmatic method of using routinely collected data to identify positively deviant elderly medical wards; however, it also highlights the various challenges that are faced when conducting the first stage of the positive deviance approach. UK Clinical Research Network Portfolio (reference-18050). © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Taylor, Natalie; Kellar, Ian; Pye, Victoria; Mohammed, Mohammed A; Lawton, Rebecca
2018-01-01
Objective The positive deviance approach seeks to identify and learn from exceptional performers. Although a framework exists to apply positive deviance within healthcare organisations, there is limited guidance to support its implementation. The approach has also rarely explored exceptional performance on broad outcomes, been implemented at ward level, or applied within the UK. This study develops and critically appraises a pragmatic method for identifying positively deviant wards using a routinely collected, broad measure of patient safety. Design A two-phased observational study was conducted. During phase 1, cross-sectional and temporal analyses of Safety Thermometer data were conducted to identify a discrete group of positively deviant wards that consistently demonstrated exceptional levels of safety. A group of matched comparison wards with above average performances were also identified. During phase 2, multidisciplinary staff and patients on the positively deviant and comparison wards completed surveys to explore whether their perceptions of safety supported the identification of positively deviant wards. Setting 34 elderly medical wards within a northern region of England, UK. Participants Multidisciplinary staff (n=161) and patients (n=188) clustered within nine positively deviant and comparison wards. Results Phase 1: A combination of analyses identified five positively deviant wards that performed best in the region, outperformed their organisation and performed consistently well over 12 months. Five above average matched comparator wards were also identified. Phase 2: Staff and patient perceptions of safety generally supported the identification of positively deviant wards using Safety Thermometer data, although patient perceptions of safety were less concordant with the routinely collected data. Conclusions This study tentatively supports a pragmatic method of using routinely collected data to identify positively deviant elderly medical wards; however, it also highlights the various challenges that are faced when conducting the first stage of the positive deviance approach. Trial registration number UK Clinical Research Network Portfolio (reference-18050). PMID:29453303
NASA Astrophysics Data System (ADS)
Braza, M.; Haproff, P. J.
2016-12-01
The easternmost extension of the Indus-Ysangpo suture (IYS) and Xigaze forearc complex, the Tidding Formation of northeastern India, remains the least-studied sequence representing closure of the Neotethys ocean and syn-tectonic sedimentation. In this study, we present P-T determinations coupled with detrital zircon U-Pb geochronology and detailed geologic mapping to uncover the depositional and metamorphic history of Tidding suture and forearc rocks during Himalayan orogenesis. Four mica schists were sampled from successive NW-SE-striking thrust sheets within the Dibang Valley of Arunachal Pradesh (N.E. India), southwest of the easternmost L. Cretaceous Gangdese batholith. Use of the garnet-muscovite-biotite-plagioclase (GMBP) thermobarometer and Ti-in-biotite thermometer on schist sample PH-1-8-13-26 yield peak conditions of 627 ± 28°C and 10.4 ± 1.1 kbar. Similarly, use of the garnet-biotite Fe-Mg exchange thermometer and garnet-aluminosilicate-silica-plagioclase (GASP) barometer yield 644 ± 50°C and 12 ± 1 kbar for schist sample PH-11-14-15-24 within the same thrust sheet. Both samples contain recrystallized quartz along grain boundaries and garnets contain no significant compositional zoning. At structurally lower levels, garnet chlorite schist (PH-1-8-13-8) sampled from the Mayodia klippe records peak temperatures below 650°C. Garnets display growth zoning, with increasing Mn and decreasing Fe and Mg from rim to core. Application of the Ti-in-biotite thermometer to a mafic schist (PH-1-3-13-1B) within the Mayodia klippe near a southwestward-directed thrust yields a peak temperature of 679 ± 24°C. Our study reveals metamorphism of IYS rocks occurred at deep crustal levels (>30 km) during northward Neotethys subduction. Suture rocks were subsequently exhumed by orogen-scale N-dipping thrusts during growth of the easternmost Himalayan orogen.
Empirical calibration of the clinopyroxene-garnet magnesium isotope geothermometer and implications
NASA Astrophysics Data System (ADS)
Li, Wang-Ye; Teng, Fang-Zhen; Xiao, Yilin; Gu, Hai-Ou; Zha, Xiang-Ping; Huang, Jian
2016-07-01
The large equilibrium Mg isotope fractionation between clinopyroxene and garnet observed in eclogites makes it a potential high-precision geothermometer, but calibration of this thermometer by natural samples is still limited. Here, we report Mg isotopic compositions of eclogite whole rocks as well as Mg and O isotopic compositions of clinopyroxene and garnet separates from 16 eclogites that formed at different temperatures from the Dabie orogen, China. The whole-rock δ26Mg values vary from -1.20 to +0.10 ‰. Among them, 11 samples display limited δ26Mg variations from -0.36 to -0.17 ‰, similar to those of their protoliths. The mineral separates exhibit very different δ26Mg values, from -0.39 to +0.39 ‰ for clinopyroxenes and from -1.94 to -0.81 ‰ for garnets. The clinopyroxene-garnet Mg isotope fractionation (Δ26Mgclinopyroxene-garnet = δ26Mgclinopyroxene-δ26Mggarnet) varies from 1.05 to 2.15 ‰. The clinopyroxene-garnet O isotope fractionation (Δ18Oclinopyroxene-garnet = δ18Oclinopyroxene-δ18Ogarnet) varies from -1.01 to +0.98 ‰. Equilibrium Mg isotope fractionation between clinopyroxene and garnet in the investigated samples is selected based on both the δ26Mgclinopyroxene versus δ26Mggarnet plot and the state of O isotope equilibrium between clinopyroxene and garnet. The equilibrium Δ26Mgclinopyroxene-garnet and corresponding temperature data obtained in this study, together with those available so far in literatures for natural eclogites, are used to calibrate the clinopyroxene-garnet Mg isotope thermometer. This yields a function of Δ26Mgclinopyroxene-garnet = (0.99 ± 0.06) × 106/ T 2, where T is temperature in Kelvin. The refined function not only provides the best empirically calibrated clinopyroxene-garnet Mg isotope thermometer for precise constraints of temperatures of clinopyroxene- and garnet-bearing rocks, but also has potential applications in high-temperature Mg isotope geochemistry.
Mazerolle, Stephanie M; Scruggs, Ian C; Casa, Douglas J; Burton, Laura J; McDermott, Brendon P; Armstrong, Lawrence E; Maresh, Carl M
2010-01-01
Previous research has indicated that despite awareness of the current literature on the recommended prevention and care of exertional heat stroke (EHS), certified athletic trainers (ATs) acknowledge failure to follow those recommendations. To investigate the current knowledge, attitudes, and practices of ATs regarding the recognition and treatment of EHS. Cross-sectional study. Online survey. We obtained a random sample of e-mail addresses for 1000 high school and collegiate ATs and contacted these individuals with invitations to participate. A total of 498 usable responses were received, for a 25% response rate. The survey instrument evaluated ATs' knowledge and actual practice regarding EHS and included 29 closed-ended Likert scale questions (1 = strongly disagree, 7 = strongly agree), 2 closed-ended questions rated on a Likert scale (1 = lowest value, 9 = greatest value), 8 open-ended questions, and 7 demographic questions. We focused on the open-ended and demographic questions. Although most ATs (77.1%) have read the current National Athletic Trainers' Association position statement on heat illness, only 18.6% used rectal thermometers to assess core body temperature to recognize EHS, and 49.7% used cold-water immersion to treat EHS. Athletic trainers perceived rectal thermometers as the most valid temperature assessment device when compared with other assessment devices (P
De Basilio, V; Requena, F; León, A; Vilariño, M; Picard, M
2003-08-01
Early age thermal conditioning (TC) durably improves resistance of broilers to heat stress and reduces body temperature (Tb). Three experiments on broiler chicks were conducted to evaluate the effects of TC at 5 d of age on Tb variation measured by thermometer between 4 and 7 d of age, under a tropical environment. Because manipulation of chickens to measure Tb with a thermometer may increase Tb, a preliminary experiment on 13 3-to-4-wk-old male broilers compared Tb measured by telemetry to Tb measured in the terminal colon during three successive periods at 22, 33, and 22 degrees C. During heat exposure, Tb rapidly increased by 0.9 degrees C and plateaued over 24 h. During the last period, seven of the broilers rapidly reduced Tb to a plateau lower than the initial Tb, although six broilers exhibited more variable Tb. Measurement by thermometer underestimated on average core Tb by 0.28 degrees C at 22 degrees C and by 0.57 degrees C at 33 degrees C, whereas Tb recorded by telemetry was not affected by manipulation of the chickens. TC reduced Tb 24 h later in the three experiments. Compared to unexposed control chicks (N), 12 h of TC at 40 degrees C did not significantly reduce Tb at 7 d of age, although 24 h did. TC at 38 and 40 degrees C over 24 h significantly reduced Tb variation from 4 to 7 d of age compared to N chicks, whereas 36 degrees C did not. Withdrawing feed from the chicks for 2 h prior to measurement did not significantly reduce Tb at 4 and 7 d of age, but Tb reduction due to TC was greater in fed chicks (0.28 degrees C) than in chicks without feed (0.05 degrees C). Early age thermal conditioning at 38 to 40 degrees C at 5 d of age for 24 h reduced body temperature of 7-d-old male broilers.
Küttner, Stefanie; Wüller, Johannes; Pastrana, Tania
2017-04-01
The aims of the present study were (1) to describe the prevalence of psychosocial distress in palliative care patients living at home and the related factors, and (2) to test implementation of the Distress Thermometer (DT) within a home-based palliative care service. Ours was a 15-month prospective study beginning in September of 2013 in western Germany with consecutive patients cared for by a home care palliative care service. The research was implemented during the first visit by the home care team. Patients were excluded if they were under 18 years of age, mentally or physically unable to complete the assessment questionnaires as judged by their healthcare worker, or unable to understand the German language. During the first encounter, the Distress Thermometer (DT), a Problem List (PL), and a structured questionnaire for evaluation were applied and sociodemographic and medical data collected. A total of 103 patients (response rate = 70%; mean age = 67; female = 54%; married = 67%; oncological condition = 91%; Karnofsky Performance Status [KPS] score 0-40 = 34%, 50-70 = 60%, >80 = 6%) were included. The incidence of distress (DT score ≥4) was 89.3% (mean = 6.3 ± 2.5). No statistical association was found between level of distress and sociodemographic or medical factors. The five most reported problems were "fatigue" (90%), "getting around" (84%), "eating" (63%), "bathing/dressing" (60%), and "sleep" (57%). The number of problems reported correlated with level of distress (ρ = 0.34). The DT was comprehensible, and 80% considered its completion as unremarkable, while 14% found it "relieving." A significant proportion of patients treated at home reported symptoms of distress. The most oft-mentioned problems were physical and emotional in nature. The findings of our study highlight the importance of creating new concepts and structures in order to address the psychosocial needs of patients in home care with palliative needs.
McKenzie, Brittney A.
2017-01-01
Measuring the temperature of a sample is a fundamental need in many biological and chemical processes. When the volume of the sample is on the microliter or nanoliter scale (e.g., cells, microorganisms, precious samples, or samples in microfluidic devices), accurate measurement of the sample temperature becomes challenging. In this work, we demonstrate a technique for accurately determining the temperature of microliter volumes using a simple 3D-printed microfluidic chip. We accomplish this by first filling “microfluidic thermometer” channels on the chip with substances with precisely known freezing/melting points. We then use a thermoelectric cooler to create a stable and linear temperature gradient along these channels within a measurement region on the chip. A custom software tool (available as online Supporting Information) is then used to find the locations of solid-liquid interfaces in the thermometer channels; these locations have known temperatures equal to the freezing/melting points of the substances in the channels. The software then uses the locations of these interfaces to calculate the temperature at any desired point within the measurement region. Using this approach, the temperature of any microliter-scale on-chip sample can be measured with an uncertainty of about a quarter of a degree Celsius. As a proof-of-concept, we use this technique to measure the unknown freezing point of a 50 microliter volume of solution and demonstrate its feasibility on a 400 nanoliter sample. Additionally, this technique can be used to measure the temperature of any on-chip sample, not just near-zero-Celsius freezing points. We demonstrate this by using an oil that solidifies near room temperature (coconut oil) in a microfluidic thermometer to measure on-chip temperatures well above zero Celsius. By providing a low-cost and simple way to accurately measure temperatures in small volumes, this technique should find applications in both research and educational laboratories. PMID:29284028
Canadian Consumer Food Safety Practices and Knowledge: Foodbook Study.
Murray, Regan; Glass-Kaastra, Shiona; Gardhouse, Christine; Marshall, Barbara; Ciampa, Nadia; Franklin, Kristyn; Hurst, Matt; Thomas, M Kate; Nesbitt, Andrea
2017-10-01
Understanding consumers' food safety practices and knowledge supports food safety education for the prevention of foodborne illness. The objective of this study was to describe Canadian consumer food safety practices and knowledge. This study identifies demographic groups for targeted food safety education messaging and establishes a baseline measurement to assess the effectiveness of food safety interventions over time. Questions regarding consumer food safety practices and knowledge were included in a population-based telephone survey, Foodbook, conducted from November 2014 to March 2015. The results were analyzed nationally by age group and by gender. The results showed that approximately 90% of Canadians reported taking the recommended cleaning and separating precautions when handling raw meat to prevent foodborne illness. Only 29% of respondents reported using a food thermometer when cooking any meat, and even fewer (12%) reported using a food thermometer for small cuts of meat such as chicken pieces. The majority (>80%) of Canadians were aware of the foodborne illness risks related to chicken and hamburger, but fewer (<40%) were aware of the risks related to frozen chicken nuggets, alfalfa sprouts, soft unpasteurized cheese, and unpasteurized juices. Generally, men were less likely to follow cooking instructions on packaging and took fewer steps to prevent cross-contamination than women. The youngest (18 to 29 years) age group was less likely to take steps to avoid cross-contamination and was less aware of the risks associated with eating an undercooked hamburger. The oldest (60+ years) respondents were less likely to be aware of the risks associated with raw eggs, alfalfa sprouts, and unpasteurized juice than the middle (30 to 59 years) age group. As a priority, food safety education in Canada should focus on increasing people's awareness of high-risk foods, specifically foods for which the awareness of risk found in this study was low; targeting messaging to demographic groups as appropriate; and promoting the use of food thermometers when cooking meat and poultry.
Knighting, Katherine; O'Brien, Mary R; Roe, Brenda; Gandy, Rob; Lloyd-Williams, Mari; Nolan, Mike; Jack, Barbara A
2015-05-03
There is an increasing international policy direction to promote home death for dying patients which will impact on the demands placed on family carers. The early identification of carer needs and appropriate intervention can help avoid crisis situations for the carer and avoidable hospital admissions which are reported to be a global concern. The aim of the study was to explore what professionals and carers of patients with cancer and advanced progressive illness, in their last year of life, find burdensome and to develop an alert system for use by non-specialist staff. A mixed-method, multi-phased, consensus study sequentially utilising qualitative and quantitative data to develop and pilot the Carers' Alert Thermometer (CAT). 245 people (117 carers and 128 professionals) participated in the study across a range of health and social care settings in the North West of England (2011-2014). A number of key domains were identified and prioritised by consensus for inclusion in the CAT. The 8 domains fit within two overarching themes of the reported carer experience; the support needed by the carer to provide care and the support needed for the carer's own health and well-being. The resultant CAT is an evidence-based alert thermometer consisting of 10 questions, guidance on the possible actions for each alert and space for an action plan to be jointly agreed by the assessor and carer. Preliminary piloting of the CAT has shown it to be valued, fit for purpose and it can be administered by a range of personnel. The CAT enables the identification of current and potential future needs so a proactive approach can be taken to supporting the carer as their role develops over time, with a view to enhancing their well-being and preventing avoidable hospital admissions; ultimately supporting patient choice to remain in their own home.
McFarland, Daniel C; Andreotti, Charissa; Harris, Kirk; Mandeli, John; Tiersten, Amy; Holland, Jimmie
2016-01-01
Certain vulnerability factors have been found to place patients at risk for depression and anxiety, especially within the context of medical illness. We sought to describe the relationships among early childhood adversity (ECA) and anxiety, depression and distress in patients with breast cancer. Patients with breast cancer (stages 0-IV) were assessed for ECA (i.e., the Risky Families Questionnaire subscales include Abuse/Neglect/Chaotic Home Environment), distress (i.e., Distress Thermometer and Problem List), anxiety (Hospital Anxiety and Depression Scale-Anxiety), depression (Hospital Anxiety and Depression Scale-Depression), meeting standardized cut-off thresholds for distress (Distress Thermometer and Problem List ≥4 or ≥7)/anxiety (Hospital Anxiety and Depression Scale-Anxiety ≥8)/depression (Hospital Anxiety and Depression Scale-Depression ≥8) and demographic factors. A total of 125 participants completed the study (78% response rate). ECA was associated with depression (p <0.001), anxiety (p = 0.001), and distress (p = 0.006), meeting cut-off threshold criteria for distress (p = 0.024), anxiety (p = 0.048), and depression (p = 0.001). On multivariate analysis, only depression (p = 0.04) and emotional issues (i.e., component of Distress Thermometer and Problem List) (p = 0.001) were associated with ECA. Neglect, but not Abuse and Chaotic Home Environment, was associated with depression (β = 0.442, p < 0.001), anxiety (β = 0.342, p = 0.002), and self-identified problems with family (β = 0.288, p = 0.022), emotion (β = 0.345, p = 0.004), and physical issues (β = 0.408, p < 0.001). ECA and neglect are associated with multiple psychologic symptoms, but most specifically depression in the setting of breast cancer. ECA contributes to psychologic burden as a vulnerability factor. ECA may help to explain individual patient trajectories and influence the provision of patient-centered care for psychologic symptoms in patients with breast cancer. Copyright © 2016 The Academy of Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Şengün, Fırat; Zack, Thomas
2016-08-01
In northwest Turkey, ophiolitic meta-gabbros are exposed on the Kazdağ Massif located in the southern part of the Biga Peninsula. Trace element composition of rutile and Zr-in-rutile temperatures were determined for meta-gabbros from the Kazdağ Massif. The Zr content of all rutiles range from 176 to 428 ppm and rutile grains usually have a homogeneous Zr distribution. The rutile grains from studied samples in the Kazdağ Massif are dominated by subchondritic Nb/Ta (11-19) and Zr/Hf ratios (20-33). Nb/Ta and Zr/Hf show positive correlation, which is probably produced by silicate fractionation. The Nb/Ta and Zr/Hf ratios increase with a decrease in Ta and Hf contents. The core of rutile grains are generally characterized by low Nb/Ta ratios of 17-18 whereas the rims exhibit relatively high Nb/Ta ratios of 19-23. Trace element analyses in rutile suggest that these rutile grains were grown from metamorphic fluids. The P-T conditions of meta-gabbros were estimated by both Fe-Mg exchange and Zr-in-rutile thermometers, as well as by the Grt-Hb-Plg-Q geothermobarometer. The temperature range of 639 to 662 °C calculated at 9 kbar using the Zr-in-rutile thermometer is comparable with temperature estimates of the Fe-Mg exchange thermometer, which records amphibolite-facies metamorphism of intermediate P-T conditions. The P-T conditions of meta-ophiolitic rocks suggest that they occur as a different separate higher-pressure tectonic slice in the Kazdağ metamorphic sequence. Amphibolite-facies metamorphism resulted from northward subduction of the İzmir-Ankara branch of the Neo-Tethyan Ocean under the Sakarya Zone. Metamorphism was followed by internal imbrication of the Kazdağ metamorphic sequence resulting from southerly directed compression during the collision.
Zhou, You; Zhang, Denan; Zeng, Jin; Gan, Ning; Cuan, Jing
2018-05-01
Luminescent MOF materials with tunable emissions and energy/charge transfer processes have been extensively explored as ratiometric temperature sensors. However, most of the ratiometric MOF thermometers reported thus far are based on the MOFs containing photoactive lanthanides, which are potentially facing cost issue and serious supply shortage. Here, we present a ratiometric luminescent thermometer based on a dual-emitting lanthanide-free MOF hybrid, which is developed by encapsulation of a fluorescent dye into a robust nanocrystalline zirconium-based MOF through a one-pot synthesis approach. The structure and morphology of the hybrid product was characterized by Powder X-ray diffraction (PXRD), N 2 adsorption-desorption measurement and Scanning electron microscopy (SEM). The pore confinement effect well isolates the guest dye molecules and therefore suppresses the nonradiative energy transfer process between dye molecules. The incorporated dye emission is mainly sensitized by the organic linkers within MOF through fluorescence resonance energy transfer. The ratiometric luminescence of the MOF hybrid shows a significant response to temperature due to the thermal-related back energy transfer process from dye molecules and organic linkers, thus can be exploited for self-calibrated temperature sensing. The maximum thermometric sensitivity is 1.19% °C -1 in the physiological temperature range, which is among the highest for the ratiomtric MOF thermometers that operating in 25-45°C. The temperature resolution is better than 0.1°C over the entire operative range (20-60°C). By integrating the advantages of excellent stability, nanoscale nature, and high sensitivity and precision in the physiological temperature range, this dye@MOF hybrid might have potential application in biomedical diagnosis. What' more, this work has expanded the possibility of non-lanthanide luminescent MOF materials for the development of ratiometric temperature sensors. Copyright © 2018 Elsevier B.V. All rights reserved.
Homma, Mitsumasa; Takei, Yoshiaki; Murata, Atsushi; Inoue, Takafumi; Takeoka, Shinji
2015-04-11
Mitochondrial thermodynamics is the key to understand cellular activities related to homeostasis and energy balance. Here, we report the first ratiometric fluorescent molecular probe (Mito-RTP) that is selectively localized in the mitochondria and visualize the temperature. We confirmed that Mito-RTP could work as a ratiometric thermometer in a cuvette and living cells.
Solar hot water system installed at Mobile, Alabama
NASA Technical Reports Server (NTRS)
1980-01-01
The system consists of six rows of ten collectors and three rows of eleven collectors (1990 square feet) mounted on the roof. Griswald flow control valves were installed to regulate the flow to each row. Two Heliotrope electronic thermometers with a combined capability of measuring the temperatures of 22 different locations were installed for monitoring purposes.
Heat conduction errors and time lag in cryogenic thermometer installations
NASA Technical Reports Server (NTRS)
Warshawsky, I.
1973-01-01
Installation practices are recommended that will increase rate of heat exchange between the thermometric sensing element and the cryogenic fluid and that will reduce the rate of undesired heat transfer to higher-temperature objects. Formulas and numerical data are given that help to estimate the magnitude of heat-conduction errors and of time lag in response.
Fast, Computer Supported Experimental Determination of Absolute Zero Temperature at School
ERIC Educational Resources Information Center
Bogacz, Bogdan F.; Pedziwiatr, Antoni T.
2014-01-01
A simple and fast experimental method of determining absolute zero temperature is presented. Air gas thermometer coupled with pressure sensor and data acquisition system COACH is applied in a wide range of temperature. By constructing a pressure vs temperature plot for air under constant volume it is possible to obtain--by extrapolation to zero…
Getting Third Graders to Put on Their Science "Thinking Caps"
ERIC Educational Resources Information Center
Raje, Sonali; Bartleson, Elizabeth
2013-01-01
This article describes how a third grade class (ages 8-9) conducted a temperature-related science experiment. The goal of the experiment was to build on the following question: What would happen if you took three different thermometers, all reading the same temperature, wrapped them in three different socks, one woollen, one silk, and one cotton,…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-16
... consumption. (See Section for ``all flow meters, weigh III.B.6). scales, pressure gauges and thermometers... apportioning consumption. (See Section III.B.8). factors by using direct measurements using gas flow meters or... consumption. Revising 40 CFR 98.94(c)(2)(i) to allow reporters to select a period of the reporting year and...
Understanding the Clausius-Clapeyron Equation by Employing an Easily Adaptable Pressure Cooker
ERIC Educational Resources Information Center
Galleano, Monica; Boveris, Alberto; Puntarulo, Susana
2008-01-01
This article describes a simple and inexpensive laboratory exercise developed to understand the effect of pressure on phase equilibrium as described by the Clausius-Clapeyron equation. The only piece of equipment required is a pressure cooker adapted with a pressure gauge and a thermometer in the lid, allowing the measurement of the pressure and…
Physics Demonstrations with the Arduino Board
ERIC Educational Resources Information Center
Kubínová, Štepánka; Šlégr, Jan
2015-01-01
In everyday praxis we often need to demonstrate measuring devices--such as thermometers, manometers and voltmeters--with large enough displays that they can easily be read from anywhere in the classroom. In some cases, computers with a measurement interface can be used as a substitute, but often this is not possible (for example in the lab or in…
ChemDuino: Adapting Arduino for Low-Cost Chemical Measurements in Lecture and Laboratory
ERIC Educational Resources Information Center
Kubínova´, S?te?pa´nka; S?le´gr, Jan
2015-01-01
In everyday praxis, we often need demonstration measuring devices (thermometers, pH meters, etc.), with large enough displays to be easily readable from every point in the classroom. Here, we present some of the capabilities of the Arduino platform for the school environment. This microprocessor board can be used for inexpensive construction of…
Use of Cometabolic Air Sparging to Remediate Chloroethene-Contaminated Groundwater Aquifers
2001-07-31
sampling event, the temperature, dew point , and relative humidity of the soil gas were analyzed using a Control Company Digital Hygrometer/Thermometer...4.2.1.3 Groundwater and Soil- Gas Multi-Level Monitoring Points .................... 20 4.2.1.4 Groundwater Monitoring Wells...C-1 APPENDIX D: SOIL- GAS MONITORING POINT DATA........................................................D-1 APPENDIX E: HISTORICAL
9 CFR 113.29 - Determination of moisture content in desiccated biological products.
Code of Federal Regulations, 2014 CFR
2014-01-01
... bottles with airtight glass stoppers. (2) Vacuum oven equipped with validated thermometer and thermostat... samples of completed product shall be tested. The weight loss of the sample due to drying in a vacuum oven... labeled sample-weighing bottles with stoppers should be allowed to dry at 60 ±3 °C under vacuum at less...
9 CFR 113.29 - Determination of moisture content in desiccated biological products.
Code of Federal Regulations, 2013 CFR
2013-01-01
... bottles with airtight glass stoppers. (2) Vacuum oven equipped with validated thermometer and thermostat... samples of completed product shall be tested. The weight loss of the sample due to drying in a vacuum oven... labeled sample-weighing bottles with stoppers should be allowed to dry at 60 ±3 °C under vacuum at less...
9 CFR 113.29 - Determination of moisture content in desiccated biological products.
Code of Federal Regulations, 2012 CFR
2012-01-01
... bottles with airtight glass stoppers. (2) Vacuum oven equipped with validated thermometer and thermostat... samples of completed product shall be tested. The weight loss of the sample due to drying in a vacuum oven... labeled sample-weighing bottles with stoppers should be allowed to dry at 60 ±3 °C under vacuum at less...
1979-04-01
welding and wood bon~ij u ~~, in medical equipment for heat treatment and burn surgery, in police speed checks and in burglar alarms. Frequencies vary...with a thermistor thermometer. The mice were weighed every morning between 7 and 8 o’clock. At the beginning of the investigation the animals , male
ERIC Educational Resources Information Center
Stallman, Helen M.; King, Sharron
2016-01-01
The increasing awareness and impact of mental health problems in university students in addition to a need for objective measures of teaching quality provide the impetus for a new approach to supporting students. There is a need for more effective tools that integrate the institutional silos of teaching, learning, support, and wellbeing to help…
21 CFR 161.175 - Frozen raw breaded shrimp.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) Thermometer (immersion type) accurate to ±2 °F. (ix) Copper sulfate crystals (CuSo4·5H2O). (2) Procedure. (i... the exact dip time required for “debreading” the composite units in a sample. For these trials only, a... correct dip time is the minimum time of immersion in the copper sulfate solution required before the...
21 CFR 161.175 - Frozen raw breaded shrimp.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) Thermometer (immersion type) accurate to ±2 °F. (ix) Copper sulfate crystals (CuSo4·5H2O). (2) Procedure. (i... the exact dip time required for “debreading” the composite units in a sample. For these trials only, a... correct dip time is the minimum time of immersion in the copper sulfate solution required before the...
21 CFR 161.175 - Frozen raw breaded shrimp.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) Thermometer (immersion type) accurate to ±2 °F. (ix) Copper sulfate crystals (CuSo4·5H2O). (2) Procedure. (i... the exact dip time required for “debreading” the composite units in a sample. For these trials only, a... correct dip time is the minimum time of immersion in the copper sulfate solution required before the...
Heat conduction errors and time lag in cryogenic thermometer installations
NASA Technical Reports Server (NTRS)
Warshawsky, I.
1973-01-01
Installation practices are recommended that will increase rate of heat exchange between the thermometric sensing element and the cryogenic fluid, in addition to bringing about a reduction in the rate of undesired heat transfer to higher temperature objects. Formulas and numerical data are given that help to estimate the magnitude of heat conduction errors and of time lag in response.
Maximilian P. W. Schneider; Lacey A. Pyle; Kenneth L. Clark; William C. Hockaday; Caroline A. Masiello; Michael W.I. Schmidt
2013-01-01
The maximum temperature experienced by biomass during combustion has a strong effect on chemical properties of the resulting charcoal, such as sorption capacity (water and nonpolar materials) and microbial degradability. However, information about the formation temperature of natural charcoal can be difficult to obtain in ecosystems that are not instrumented prior to...
Effects of Art Therapy on Distress Levels of Adults with Cancer: A Proxy Pretest Study
ERIC Educational Resources Information Center
Glinzak, Leara
2016-01-01
This study identified decreased distress after art therapy in a proxy pretest study with a convenience sample of 73 patients being treated for cancer. Art therapy outcomes from 4 settings (oncology unit, infusion clinic, individual sessions, and open studio) were measured via the self-report Distress Thermometer, which was collected as part of an…
NASA Technical Reports Server (NTRS)
Kinard, William H.; Murray, Robert C.; Walsh, Robert F.
1987-01-01
Space-qualified, precise, large-force, thermally activated driver (TAD) developed for use in space on astro-physics experiment to measure abundance of rare actinide-group elements in cosmic rays. Actinide cosmic rays detected using thermally activated driver as heart of event-thermometer (ET) system. Thermal expansion and contraction of silicone oil activates driver. Potential applications in fluid-control systems where precise valve controls are needed.
Kouzoupis, Anastasios V; Lyrakos, Dimitrios; Kokras, Nikolaos; Panagiotarakou, Meropi; Syrigos, Kostas N; Papadimitriou, George N
2012-12-01
Evidence suggests that gender differences appear in a variety of biological and psychological responses to stress and perhaps in coping with acute and chronic illness as well. Dysfunctional parenting is also thought to be involved in the process of coping with stress and illness; hence, the present study aimed to verify whether dysfunctional remembered parenting would influence psychological distress in a gender-specific manner in patients suffering from cancer. Patients attending an outpatient oncology clinic completed the Remembered Relationships with Parents (RRP), Hospital Anxiety and Depression and Spielberger's State-Trait Anxiety Inventory scales and the National Cancer Center Network Distress Thermometer. Although no baseline gender differences were detected, a multivariate analysis confirmed that anxiety and depression symptoms of men and women suffering from cancer are differentially affected by the RRP Control and Alienation scores. Women with remembered parental alienation and overprotection showed significantly more anxiety symptoms than men, whereas men were more vulnerable to remembered alienation than overprotection with regard to the Distress Thermometer scores. These results suggest that remembered dysfunctional parenting is crucially, and in a gender-specific manner, involved in the coping strategy adopted by male and female cancer patients. Copyright © 2012 John Wiley & Sons, Ltd.
Du, Zhongzhou; Su, Rijian; Liu, Wenzhong; Huang, Zhixing
2015-01-01
The signal transmission module of a magnetic nanoparticle thermometer (MNPT) was established in this study to analyze the error sources introduced during the signal flow in the hardware system. The underlying error sources that significantly affected the precision of the MNPT were determined through mathematical modeling and simulation. A transfer module path with the minimum error in the hardware system was then proposed through the analysis of the variations of the system error caused by the significant error sources when the signal flew through the signal transmission module. In addition, a system parameter, named the signal-to-AC bias ratio (i.e., the ratio between the signal and AC bias), was identified as a direct determinant of the precision of the measured temperature. The temperature error was below 0.1 K when the signal-to-AC bias ratio was higher than 80 dB, and other system errors were not considered. The temperature error was below 0.1 K in the experiments with a commercial magnetic fluid (Sample SOR-10, Ocean Nanotechnology, Springdale, AR, USA) when the hardware system of the MNPT was designed with the aforementioned method. PMID:25875188
Aromatherapy hand massage for older adults with chronic pain living in long-term care.
Cino, Kathleen
2014-12-01
Older adults living in long-term care experience high rates of chronic pain. Concerns with pharmacologic management have spurred alternative approaches. The purpose of this study was to examine a nursing intervention for older adults with chronic pain. This prospective, randomized control trial compared the effect of aromatherapy M technique hand massage, M technique without aromatherapy, and nurse presence on chronic pain. Chronic pain was measured with the Geriatric Multidimensional Pain and Illness Inventory factors, pain and suffering, life interference, and emotional distress and the Iowa Pain Thermometer, a pain intensity scale. Three groups of 39 to 40 participants recruited from seven long-term care facilities participated twice weekly for 4 weeks. Analysis included multivariate analysis of variance and analysis of variance. Participants experienced decreased levels of chronic pain intensity. Group membership had a significant effect on the Geriatric Multidimensional Pain Inventory Pain and Suffering scores; Iowa Pain Thermometer scores differed significantly within groups. M technique hand massage with or without aromatherapy significantly decreased chronic pain intensity compared to nurse presence visits. M technique hand massage is a safe, simple, but effective intervention. Caregivers using it could improve chronic pain management in this population. © The Author(s) 2014.
High-resolution, large dynamic range fiber-optic thermometer with cascaded Fabry-Perot cavities.
Liu, Guigen; Sheng, Qiwen; Hou, Weilin; Han, Ming
2016-11-01
The paradox between a large dynamic range and a high resolution commonly exists in nearly all kinds of sensors. Here, we propose a fiber-optic thermometer based on dual Fabry-Perot interferometers (FPIs) made from the same material (silicon), but with different cavity lengths, which enables unambiguous recognition of the dense fringes associated with the thick FPI over the free-spectral range determined by the thin FPI. Therefore, the sensor combines the large dynamic range of the thin FPI and the high resolution of the thick FPI. To verify this new concept, a sensor with one 200 μm thick silicon FPI cascaded by another 10 μm thick silicon FPI was fabricated. A temperature range of -50°C to 130°C and a resolution of 6.8×10-3°C were demonstrated using a simple average wavelength tracking demodulation. Compared to a sensor with only the thick silicon FPI, the dynamic range of the hybrid sensor was more than 10 times larger. Compared to a sensor with only the thin silicon FPI, the resolution of the hybrid sensor was more than 18 times higher.
Sabec, D; Lazar, P
1990-01-01
The surface temperature on tarsus of 54 performance tested boars of about 60 kg of Swedish Landrace was measured by means of infra-red thermometer at three measuring points (MP1, MP2 and MP3). MP1 was situated above the tuberculum of os metatarsale III or, as visualised in 21 slaughtered boars, above pathoanatomical alterations of osteoarthrosis tarsi deformans (OATD). MP2 was located directly medially and MP3 laterally from MP1. A clear palpatory symptom was found only with 10 boars, while all 21 slaughtered boars showed different morphological lesions of OATD. The average temperature at MP1 was 35.69 degrees C and was significantly higher (P = .01) than at MP2 (35.34) and MP3 (35.30). The temperature differences between MP1 and MP2 or MP3 were statistically reliable. Boars, who had a clear palpatory symptoms at tuberculum, showed an average temperature at MT1 of 36.27 degrees C, which was higher (P = .0114) than of those with an unclear palpatory symptom (35.64 degrees C). The results show that the temperature differences are the consequence of OATD.
Evaluation of Infrared Thermometry in Cynomolgus Macaques (Macaca fascicularis).
Laffins, Michael M; Mellal, Nacera; Almlie, Cynthia L; Regalia, Douglas E
2017-01-01
Recording an accurate body temperature is important to assess an animal's health status. We compared temperature data from sedated cynomolgus macaques (Macaca fascicularis) to evaluate differences between rectal, infrared (inguinal and chest), and implanted telemetry techniques with the objective of demonstrating the diagnostic equivalence of the infrared device with other approaches. Infrared thermometer readings are instantaneous and require no contact with the animal. Body temperature data were obtained from 205 (137 male, 68 female) cynomolgus macaques under ketamine (10 mg/kg IM) sedation over a 3-mo period during scheduled physical examinations. Infrared measurements were taken 5 cm from the chest and inguinal areas. We evaluated 10 (9 functional devices) sedated cynomolgus macaques (5 male, 5 female) implanted with telemetry units in a muscular pouch between the internal and external abdominal oblique muscles. We determined that the mean body temperature acquired by using telemetry did not differ from either the mean of inguinal and chest infrared measurements but did differ from the mean of temperature obtained rectally. In addition, the mean rectal temperature differed from the mean of the inguinal reading but not the mean of the chest temperature. The results confirm our hypothesis that the infrared thermometer can be used to replace standard rectal thermometry.
McCabe, Kevin M.; Hernandez, Mark
2010-01-01
Conventional temperature measurements rely on material responses to heat, which can be detected visually. When Galileo developed an air expansion based device to detect temperature changes, Santorio, a contemporary physician, added a scale to create the first thermometer. With this instrument, patients’ temperatures could be measured, recorded and related to changing health conditions. Today, advances in materials science and bioengineering provide new ways to report temperature at the molecular level in real time. In this review the scientific foundations and history of thermometry underpin a discussion of the discoveries emerging from the field of molecular thermometry. Intracellular nanogels and heat sensing biomolecules have been shown to accurately report temperature changes at the nano-scale. Various systems will soon provide the ability to accurately measure temperature changes at the tissue, cellular, and even sub-cellular level, allowing for detection and monitoring of very small changes in local temperature. In the clinic this will lead to enhanced detection of tumors and localized infection, and accurate and precise monitoring of hyperthermia based therapies. Some nanomaterial systems have even demonstrated a theranostic capacity for heat-sensitive, local delivery of chemotherapeutics. Just as early thermometry moved into the clinic, so too will these molecular thermometers. PMID:20139796
Ultrafast Dynamics of Energetic Materials
2014-01-23
redistributed in condensed-phase materials. In this subproject we developed a technique termed three-dimensional IR- Raman spectroscopy that allowed us to...Fang, 2011, “The distribution of local enhancement factors in surface enhanced Raman -active substrates and the vibrational dynamics in the liquid phase...3. (invited) “Vibrational energy and molecular thermometers in liquids: Ultrafast IR- Raman spectroscopy”, Brandt C. Pein and Dana D. Dlott, To
10 CFR 32.101 - Schedule B-prototype tests for luminous safety devices for use in aircraft.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Schedule B-prototype tests for luminous safety devices for... thermometer. (d) Shock test. The device shall be dropped upon a concrete or iron surface in a 3-foot free gravitational fall, or shall be subjected to equivalent treatment in a test device simulating such a free fall...
Comparison of Behavioral Treatments for Raynaud’s Disease,
1984-01-01
biofeedback with other treatment modes (6, 9-10). Hypnosis and relaxation have also received attention as treatments for vasoconstrictive syndromes (11). Surwit...sedimentation rate, antinuclear antibody, and serum glucose levels. All test results were within normal limits. Instrumentation : The temperature reponse...manufactured by the Yellow Springs Instrument Co., Yellow Springs, OH. 3. Thermal feedback was provided by an Autogen 1000b feedback thermometer, and
49 CFR Appendix H to Part 173 - Method of Testing for Sustained Combustibility
Code of Federal Regulations, 2013 CFR
2013-10-01
... the well when in the test position. (c) Light the butane test fuel with the jet away from the test... used. The block has a concave well and a pocket drilled to take a thermometer. A small gas jet assembly on a swivel is attached to the block. The handle and gas inlet for the gas jet may be fitted at any...
49 CFR Appendix H to Part 173 - Method of Testing for Sustained Combustibility
Code of Federal Regulations, 2012 CFR
2012-10-01
... the well when in the test position. (c) Light the butane test fuel with the jet away from the test... used. The block has a concave well and a pocket drilled to take a thermometer. A small gas jet assembly on a swivel is attached to the block. The handle and gas inlet for the gas jet may be fitted at any...
49 CFR Appendix H to Part 173 - Method of Testing for Sustained Combustibility
Code of Federal Regulations, 2014 CFR
2014-10-01
... the well when in the test position. (c) Light the butane test fuel with the jet away from the test... used. The block has a concave well and a pocket drilled to take a thermometer. A small gas jet assembly on a swivel is attached to the block. The handle and gas inlet for the gas jet may be fitted at any...
49 CFR Appendix H to Part 173 - Method of Testing for Sustained Combustibility
Code of Federal Regulations, 2011 CFR
2011-10-01
... the well when in the test position. (c) Light the butane test fuel with the jet away from the test... used. The block has a concave well and a pocket drilled to take a thermometer. A small gas jet assembly on a swivel is attached to the block. The handle and gas inlet for the gas jet may be fitted at any...
Hysteresis of thin film IPRTs in the range 100 °C to 600 °C
NASA Astrophysics Data System (ADS)
Zvizdić, D.; Šestan, D.
2013-09-01
As opposed to SPRTs, the IPRTs succumb to hysteresis when submitted to change of temperature. This uncertainty component, although acknowledged as omnipresent at many other types of sensors (pressure, electrical, magnetic, humidity, etc.) has often been disregarded in their calibration certificates' uncertainty budgets in the past, its determination being costly, time-consuming and not appreciated by customers and manufacturers. In general, hysteresis is a phenomenon that results in a difference in an item's behavior when approached from a different path. Thermal hysteresis results in a difference in resistance at a given temperature based on the thermal history to which the PRTs were exposed. The most prominent factor that contributes to the hysteresis error in an IPRT is a strain within the sensing element caused by the thermal expansion and contraction. The strains that cause hysteresis error are closely related to the strains that cause repeatability error. Therefore, it is typical that PRTs that exhibit small hysteresis also exhibit small repeatability error, and PRTs that exhibit large hysteresis have poor repeatability. Aim of this paper is to provide hysteresis characterization of a batch of IPRTs using the same type of thin-film sensor, encapsulated by same procedure and same company and to estimate to what extent the thermal hysteresis obtained by testing one single thermometer (or few thermometers) can serve as representative of other thermometers of the same type and manufacturer. This investigation should also indicate the range of hysteresis departure between IPRTs of the same type. Hysteresis was determined by cycling IPRTs temperature from 100 °C through intermediate points up to 600 °C and subsequently back to 100 °C. Within that range several typical sub-ranges are investigated: 100 °C to 400 °C, 100 °C to 500 °C, 100 °C to 600 °C, 300 °C to 500 °C and 300 °C to 600 °C . The hysteresis was determined at various temperatures by comparison calibration with SPRT. The results of investigation are presented in a graphical form for all IPRTs, ranges and calibration points.
Composite Ceramic Superconducting Wires for Electric Motor Applications
1989-04-28
anneal, reaching a zero stress condition. One must consider the kinetics of stress relaxation to estimate the retained residual stress. Also, upon cooling...temperature residual stress. Starting from zero stress after intercalation, thermomechanical stress builds up from around 300’C or so, depending upon...silicon diode thermometer. The sample filament is electroded in a four-point geometry using either silver epoxy over sputteredd silver pads or fired-on
Response time for multilayered platinum resistance thermometers
NASA Technical Reports Server (NTRS)
Pandey, D. K.; Ash, R. L.
1985-01-01
Response time constants for several multilayered temperature transducers were determined numerically by using Martin Marietta's MITAS software package which is available at NASA Langley Research Center. Present results were found in close agreement with the solutions reported in the literature, thus, the capability of MITAS was justified. On the basis of experiences gained, the MITAS is recommended for use in predicting the response time constants of sensors by an in-situ technique.
Alimov, A V; Aminev, R M; Ustinov, A E; Matreninskaia, E S
2011-01-01
In the article are presented the technologies, regular usage of which let attain important decrease of the level of airborne infections in the period of epidemic. These technologies are noncontact infared thermometer "Kelvin-kompakt" 201 (M1), medication in aerosol packing "Bakteroks Mentol" for the air disinfection in small rooms (medical squadron, unauthorized sick-room), photocatalytic air disinfectant "Airlife".
Robust microfluidic encapsulation of cholesteric liquid crystals toward photonic ink capsules.
Lee, Sang Seok; Kim, Bomi; Kim, Su Kyung; Won, Jong Chan; Kim, Yun Ho; Kim, Shin-Hyun
2015-01-27
Robust photonic microcapsules are created by microfluidic encapsulation of cholesteric liquid crystals with a hydrogel membrane. The membrane encloses the cholesteric core without leakage in water and the core exhibits pronounced structural colors. The photonic ink capsules, which have a precisely controlled bandgap position and size, provide new opportunities in colorimetric micro-thermometers and optoelectric applications. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Electrocaloric Refrigeration for Superconductors
1977-02-01
Dielectric properties 40 3.3.2. Relation to capacitance thermometer manufacturing . . 42 3.4. SrTiO, Glass-Ceramic Multilayer Samples 42 3.4.1...Experimental Methods 66 3.6.1. Dielectric properties 66 3.6.2. Thermodynamic properties 7 0 3.6.3. Thermal conductivity. .... 80 3.7...Discussion of Experimental Results 143 3.8.1. Dielectric Troperties 143 3.8.2. Thermal Properties 150 3.8.3. Recommendations for further work
Multi-channel infrared thermometer
Ulrickson, Michael A.
1986-01-01
A device for measuring the two-dimensional temperature profile of a surface comprises imaging optics for generating an image of the light radiating from the surface; an infrared detector array having a plurality of detectors; and a light pipe array positioned between the imaging optics and the detector array for sampling, transmitting, and distributing the image over the detector surfaces. The light pipe array includes one light pipe for each detector in the detector array.
Microcantilever heater-thermometer with integrated temperature-compensated strain sensor
King, William P [Champaign, IL; Lee, Jungchul [Champaign, IL; Goericke, Fabian T [Wolfsburg, DE
2011-04-19
The present invention provides microcantilever hotplate devices which incorporate temperature compensating strain sensors. The microcantilever hotplate devices of the present invention comprise microcantilevers having temperature compensating strain sensors and resistive heaters. The present invention also provides methods for using a microcantilever hotplate for temperature compensated surface stress measurements, chemical/biochemical sensing, measuring various properties of compounds adhered to the microcantilever hotplate surface, or for temperature compensated deflection measurements.
C-QDs@UiO-66-(COOH)2 Composite Film via Electrophoretic Deposition for Temperature Sensing.
Feng, Ji-Fei; Gao, Shui-Ying; Shi, Jianlin; Liu, Tian-Fu; Cao, Rong
2018-03-05
Temperature plays a crucial role in both scientific research and industry. However, traditional temperature sensors, such as liquid-filled thermometers, thermocouples, and transistors, require contact to obtain heat equilibrium between the probe and the samples during the measurement. In addition, traditional temperature sensors have limitations when being used to detect the temperature change of fast-moving samples at smaller scales. Herein, the carbon quantum dots (C-QDs) functionalized metal-organic framework (MOF) composite film, a novel contactless solid optical thermometer, has been prepared via electrophoretic deposition (EPD). Instead of terephthalic acid (H 2 BDC), 1',2',4',5'-benzenetetracarboxylic (H 4 BTEC) acid was employed to construct a UiO-66 framework to present two uncoordinated carboxylic groups decorated on the pore surface. The uncoordinated carboxylic groups can generate negative charges, which facilitates the deposition of film on the positive electrode during the EPD process. Moreover, UiO-66-(COOH) 2 MOFs can absorb C-QDs from the solution and prevent C-QDs from aggregating, and the well-dispersed C-QDs impart fluorescence characteristics to composites. As-synthesized composite film was successfully used to detect temperature change in the range of 97-297 K with a relative sensitivity up to 1.3% K -1 at 297 K.
NASA Technical Reports Server (NTRS)
Stevenson, Thomas R.; Balvin, M. A.; Denis, K. L.; Hsieh, W.-T.; Sadleir, J. E.; Bandler, Simon E.; Busch, Sarah E.; Merrell, W.; Kelly, Daniel P.; Nagler, Peter C.;
2012-01-01
We have made high resolution x-ray microcalorimeters using superconducting MoAu bilayers and Nb meander coils. The temperature sensor is a Magnetic Penetration Thermometer (MPT). Operation is similar to metallic magnetic calorimeters, but instead of the magnetic susceptibility of a paramagnetic alloy, we use the diamagnetic response of the superconducting MoAu to sense temperature changes in an x-ray absorber. Flux-temperature responsivtty can be large for small sensor heat capacity, with enough dynamic range for applications. We find models of observed flux-temperature curves require several effects to explain flux penetration or expulsion in the microscopic devices. The superconductor is non-local, with large coherence length and weak pinning of flux. At lowest temperatures, behavior is dominated by screening currents that vary as a result of the temperature dependence of the magnetic penetration depth, modified by the effect of the nonuniformity of the applied field occurring on a scale comparable to the coherence length. In the temperature regime where responslvity is greatest, spadal variations in the order parameter become important: both local variations as flux enters/leaves the film and an intermediate state is formed, and globally as changing stability of the electrical circuit creates a Meissner transition and flux is expelled/penetrates to minimize free energy.
Metal Carbon Eutectics to Extend the Use of the Fixed-Point Technique in Precision IR Thermometry
NASA Astrophysics Data System (ADS)
Battuello, M.; Girard, F.; Florio, M.
2008-06-01
The high-temperature extension of the fixed-point technique for primary calibration of precision infrared (IR) thermometers was investigated both through mathematical simulations and laboratory investigations. Simulations were performed with Co C (1,324°C) and Pd C (1, 492°C) eutectic fixed points, and a precision IR thermometer was calibrated from the In point (156.5985°C) up to the Co C point. Mathematical simulations suggested the possibility of directly deriving the transition temperature of the Co C and Pd C points by extrapolating the calibration derived from fixed-point measurements from In to the Cu point. Both temperatures, as a result of the low uncertainty associated with the In Cu calibration and the high number of fixed points involved in the calibration process, can be derived with an uncertainty of 0.11°C for Co C and 0.18°C for Pd C. A transition temperature of 1,324.3°C for Co C was determined from the experimental verification, a value higher than, but compatible with, the one proposed by the thermometry community for inclusion as a secondary reference point for ITS-90 dissemination, i.e., 1,324.0°C.
Yang, Jie; Liu, Qingquan; Dai, Wei
2017-02-01
To improve the air temperature observation accuracy, a low measurement error temperature sensor is proposed. A computational fluid dynamics (CFD) method is implemented to obtain temperature errors under various environmental conditions. Then, a temperature error correction equation is obtained by fitting the CFD results using a genetic algorithm method. The low measurement error temperature sensor, a naturally ventilated radiation shield, a thermometer screen, and an aspirated temperature measurement platform are characterized in the same environment to conduct the intercomparison. The aspirated platform served as an air temperature reference. The mean temperature errors of the naturally ventilated radiation shield and the thermometer screen are 0.74 °C and 0.37 °C, respectively. In contrast, the mean temperature error of the low measurement error temperature sensor is 0.11 °C. The mean absolute error and the root mean square error between the corrected results and the measured results are 0.008 °C and 0.01 °C, respectively. The correction equation allows the temperature error of the low measurement error temperature sensor to be reduced by approximately 93.8%. The low measurement error temperature sensor proposed in this research may be helpful to provide a relatively accurate air temperature result.
Design of High Resolution Soft X-Ray Microcalorimeters Using Magnetic Penetration Thermometers
NASA Technical Reports Server (NTRS)
Busch. Sarah; Balvin, Manuel; Bandler, Simon; Denis, Kevin; Finkbeiner, Fred; Porst, Jan-Patrick; Sadlier, Jack; Smith, Stephen; Stevenson, Thomas
2012-01-01
We have designed high-resolution soft x-ray microcalorimeters using magnetic penetration thermometers (MPTs) in an array of pixels covering a total of 2 square centimeters to have a resolving power of 300 at energies around 300 eV. This performance is desirable for studying the soft x-ray background from the warm hot intergalactic medium. MPT devices have small sensor heat capacity and high responsivities, which makes them excellent detector technology for attempting to attain sub-eV resolution. We are investigating the feasibility of pixels with absorbers that are 625 x 625 square micrometers, up to 1 x 1 square millimeters in area and 0.35 micrometer thick and thinner. Our tests have shown that suspended gold absorbers 0.35 micrometers thick (RRR = 6.7) are feasible to fabricate. We modeled the thermal diffusion from such thin gold over the size of a 625 x 625 square micrometer absorber, and conclude that the effect of the thermalization on the resolution of a 300 eV photon is an additional approximately 0.2 eV FWHM of broadening. We discuss the thermal effects of small absorber attachment sterns on solid substrate, as well as considerations for multiplexed readout. We will present the progress we have made towards building and testing this soft x-ray detector.
Response time correlations for platinum resistance thermometers in flowing fluids
NASA Technical Reports Server (NTRS)
Pandey, D. K.; Ash, R. L.
1985-01-01
The thermal response of two types of Platinum Resistance Thermometers (PRT's), which are being considered for use in the National Transonic Wind Tunnel Facility, were studied. Response time correlations for each PRT, in flowing water, oil and air, were established separately. A universal correlation, tau WOA = 2.0 + 1264, 9/h, for a Hy-Cal Sensor (with a reference resistance of 100 ohm) within an error of 20% was established while the universal correlation for the Rosemount Sensor (with a reference resistance of 1000 ohm), tau OA = 0.122 + 1105.6/h, was found with a maximum percentage error of 30%. The correlation for the Rosemount Sensor was based on air and oil data only which is certainly not sufficient to make a correlation applicable to every condition. Therefore, the correlation needs more data to be gathered in different fluids. Also, it is necessary to state that the calculation of the parameter, h, was based on the available heat transfer correlations, whose accuracies are already reported in literature uncertain within 20-30%. Therefore, the universal response constant correlations established here for the Hy-Cal and Rosemount sensors are consistent with the uncertainty in the input data and are recommended for future use in flowing liquids and gases.
Calibration of Heat Stress Monitor and its Measurement Uncertainty
NASA Astrophysics Data System (ADS)
Ekici, Can
2017-07-01
Wet-bulb globe temperature (WBGT) equation is a heat stress index that gives information for the workers in the industrial areas. WBGT equation is described in ISO Standard 7243 (ISO 7243 in Hot environments—estimation of the heat stress on working man, based on the WBGT index, ISO, Geneva, 1982). WBGT is the result of the combined quantitative effects of the natural wet-bulb temperature, dry-bulb temperature, and air temperature. WBGT is a calculated parameter. WBGT uses input estimates, and heat stress monitor measures these quantities. In this study, the calibration method of a heat stress monitor is described, and the model function for measurement uncertainty is given. Sensitivity coefficients were derived according to GUM. Two-pressure humidity generators were used to generate a controlled environment. Heat stress monitor was calibrated inside of the generator. Two-pressure humidity generator, which is located in Turkish Standard Institution, was used as the reference device. This device is traceable to national standards. Two-pressure humidity generator includes reference temperature Pt-100 sensors. The reference sensor was sheltered with a wet wick for the calibration of natural wet-bulb thermometer. The reference sensor was centred into a black globe that has got 150 mm diameter for the calibration of the black globe thermometer.