Ran, Hong; Zhang, Ping-Yang; Zhang, You-Xiang; Zhang, Jian-Xin; Wu, Wen-Fang; Dong, Jing; Ma, Xiao-Wu
2016-08-01
To determine whether 3-dimensional (3D) speckle-tracking echocardiography could provide a new way to assess myocardial viability in patients with myocardial infarction (MI). Forty-five patients with MI underwent routine echocardiography, 2-dimensional (2D) speckle-tracking echocardiography, and 3D speckle-tracking echocardiography. Radionuclide myocardial perfusion/metabolic imaging was used as a reference standard to define viable and nonviable myocardia. Among 720 myocardial segments in 45 patients, 368 showed abnormal motion on routine echocardiography; 204 of 368 were categorized as viable on single-photon emission computed tomography/positron emission tomography (SPECT/PET), whereas 164 were defined as nonviable; 300 normal segments on SPECT/PET among 352 segments without abnormal motion on routine echocardiography were categorized as a control group. The radial, longitudinal, 3D, and area strain on 3D speckle-tracking echocardiography had significant differences between control and nonviable groups (P < .001), whereas none of the parameters had significant differences between control and viable groups. There were no significant differences in circumferential, radial, and longitudinal peak systolic strain from 2D speckle-tracking echocardiography between viable and nonviable groups. Although there was no significant difference in circumferential strain between the groups, radial and longitudinal strain from 3D speckle-tracking echocardiography decreased significantly in the nonviable group. Moreover, 3D and area strain values were lower in the nonviable segments than the viable segments. By receiver operating characteristic analysis, radial strain from 3D speckle-tracking echocardiography with a cutoff of 11.1% had sensitivity of 95.1% and specificity of 53.4% for viable segments; longitudinal strain with a cutoff of 14.3% had sensitivity of 65.2% and specificity of 65.7%; 3D strain with a cutoff of 17.4% had sensitivity of 70.6% and specificity of 77.2%; and area strain with a cutoff of 23.2% had sensitivity of 91.5% and specificity of 82.8%. Three-dimensional speckle-tracking echocardiography might have potential for detection of myocardial viability in patients with cardiac dysfunction due to MI.
Ma, Hong; Xie, Rong-Ai; Gao, Li-Jian; Zhang, Jin-Ping; Wu, Wei-Chun; Wang, Hao
2015-10-01
The purpose of this study was to investigate the diagnostic value of 3-dimensional (3D) speckle-tracking echocardiography for estimating left ventricular filling pressure in patients with coronary artery disease (CAD) and a preserved left ventricular ejection fraction. Altogether, 84 patients with CAD and 30 age- and sex-matched healthy control participants in sinus rhythm were recruited prospectively. All participants underwent conventional and 3D speckle-tracking echocardiography. Global strain values were automatically calculated by 3D speckle-tracking analysis. The left ventricular end-diastolic pressure (LVEDP) was determined invasively by left heart catheterization. Echocardiography and cardiac catheterization were performed within 24 hours. Compared with the controls, patients with CAD showed lower global longitudinal strain, global circumferential strain, global area strain, and global radial strain. Patients with CAD who had an elevated LVEDP had much lower levels of all 4 3D-speckle-tracking echocardiographic variables. Pearson correlation analysis revealed that the LVEDP correlated positively with the early transmitral flow velocity/early diastolic myocardial velocity (E/E') ratio, global longitudinal strain, global circumferential strain, and global area strain. It correlated negatively with global radial strain. Receiver operating characteristic curve analysis revealed that these 3D speckle-tracking echocardiographic indices could effectively predict elevated left ventricular filling pressure (LVEDP >15 mm Hg) in patients with CAD (areas under the curve: global longitudinal strain, 0.78; global radial strain, 0.77; global circumferential strain, 0.75; and global area strain, 0.74). These parameters, however, showed no advantages over the commonly used E/E' ratio (area under the curve, 0.84). Three-dimensional speckle-tracking echocardiography was a practical technique for predicting elevated left ventricular filling pressure, but it might not be superior to the commonly used E/E' ratio in patients with CAD who have a normal left ventricular ejection fraction. © 2015 by the American Institute of Ultrasound in Medicine.
Poyraz, Esra; Öz, Tuğba Kemaloğlu; Zeren, Gönül; Güvenç, Tolga Sinan; Dönmez, Cevdet; Can, Fatma; Güvenç, Rengin Çetin; Dayı, Şennur Ünal
2017-09-01
In a fraction of patients with mild mitral stenosis, left ventricular systolic function deteriorates despite the lack of hemodynamic load imposed by the dysfunctioning valve. Neither the predisposing factors nor the earlier changes in left ventricular contractility were understood adequately. In the present study we aimed to evaluate left ventricular mechanics using three-dimensional (3D) speckle tracking echocardiography. A total of 31 patients with mild rheumatic mitral stenosis and 27 healthy controls were enrolled to the study. All subjects included to the study underwent echocardiographic examination to collect data for two- and three-dimensional speckle-tracking based stain, twist angle and torsion measurements. Data was analyzed offline with a echocardiographic data analysis software. Patients with rheumatic mild MS had lower global longitudinal (p < 0.001) circumferential (p = 0.02) and radial (p < 0.01) strain compared to controls, despite ejection fraction was similar for both groups [(p = 0.45) for three dimensional and (p = 0.37) for two dimensional measurement]. While the twist angle was not significantly different between groups (p = 0.11), left ventricular torsion was significantly higher in mitral stenosis group (p = 0.03). All strain values had a weak but significant positive correlation with mitral valve area measured with planimetry. Subclinical left ventricular systolic dysfunction develops at an early stage in rheumatic mitral stenosis. Further work is needed to elucidate patients at risk for developing overt systolic dysfunction.
Mochizuki, Yohei; Yoshimatsu, Hiroki; Niina, Ayaka; Teshima, Takahiro; Matsumoto, Hirotaka; Koyama, Hidekazu
2018-01-01
Case summary A 5-month-old intact female Scottish Fold cat was presented for cardiac evaluation. Careful auscultation detected a slight systolic murmur (Levine I/VI). The findings of electrocardiography, thoracic radiography, non-invasive blood pressure measurements and conventional echocardiographic studies were unremarkable. However, two-dimensional speckle tracking echocardiography revealed abnormalities in myocardial deformations, including decreased early-to-late diastolic strain rate ratios in longitudinal, radial and circumferential directions, and deteriorated segmental systolic longitudinal strain. At the follow-up examinations, the cat exhibited echocardiographic left ventricular hypertrophy and was diagnosed with hypertrophic cardiomyopathy using conventional echocardiography. Relevance and novel information This is the first report on the use of two-dimensional speckle tracking echocardiography for the early detection of myocardial dysfunction in a cat with hypertrophic cardiomyopathy; the myocardial dysfunction was detected before the development of hypertrophy. The findings from this case suggest that two-dimensional speckle tracking echocardiography can be useful for myocardial assessment when conventional echocardiographic and Doppler findings are ambiguous. PMID:29449957
Speckle tracking as a method to measure hemidiaphragm excursion.
Goutman, Stephen A; Hamilton, James D; Swihart, Blake; Foerster, Bradley; Feldman, Eva L; Rubin, Jonathan M
2017-01-01
Diaphragm excursion measured via ultrasound may be an important imaging outcome measure of respiratory function. We developed a new method for measuring diaphragm movement and compared it to the more traditional M-mode method. Ultrasound images of the right and left hemidiaphragms were collected to compare speckle tracking and M-mode measurements of diaphragm excursion. Speckle tracking was performed using EchoInsight (Epsilon Imaging, Ann Arbor, Michigan). Six healthy subjects without a history of pulmonary diseases were included in this proof-of-concept study. Speckle tracking of the diaphragm is technically possible. Unlike M-mode, speckle tracking carries the advantage of reliable visualization and measurement of the left hemidiaphragm. Speckle tracking accounted for diaphragm movement simultaneously in the cephalocaudad and mediolateral directions, unlike M-mode, which is 1-dimensional. Diaphragm speckle tracking may represent a novel, more robust method for measuring diaphragm excursion, especially for the left hemidiaphragm. Muscle Nerve 55: 125-127, 2017. © 2016 Wiley Periodicals, Inc.
Urbano-Moral, Jose Angel; Gangadharamurthy, Dakshin; Comenzo, Raymond L; Pandian, Natesa G; Patel, Ayan R
2015-08-01
The study of myocardial mechanics has a potential role in the detection of cardiac involvement in patients with amyloidosis. This study aimed to characterize 3-dimensional-speckle tracking echocardiography-derived left and right ventricular myocardial mechanics in light chain amyloidosis and examine their relationship with brain natriuretic peptide. In patients with light chain amyloidosis, left ventricular longitudinal and circumferential strain (n=40), and right ventricular longitudinal strain and radial displacement (n=26) were obtained by 3-dimensional-speckle tracking echocardiography. Brain natriuretic peptide levels were determined. All myocardial mechanics measurements showed differences when compared by brain natriuretic peptide level tertiles. Left and right ventricular longitudinal strain were highly correlated (r=0.95, P<.001). Left ventricular longitudinal and circumferential strain were reduced in patients with cardiac involvement (-9±4 vs -16±2; P<.001, and -24±6 vs -29±4; P=.01, respectively), with the most prominent impairment at the basal segments. Right ventricular longitudinal strain and radial displacement were diminished in patients with cardiac involvement (-9±3 vs -17±3; P<.001, and 2.7±0.8 vs 3.8±0.3; P=.002). On multivariate analysis, left ventricular longitudinal strain was associated with the presence of cardiac involvement (odds ratio = 1.6; 95% confidence interval, 1.04 to 2.37; P=.03) independent of the presence of brain natriuretic peptide and troponin I criteria for cardiac amyloidosis. Three-dimensional-speckle tracking echocardiography-derived left and right ventricular myocardial mechanics are increasingly altered as brain natriuretic peptide increases in light chain amyloidosis. There appears to be a strong association between left ventricular longitudinal strain and cardiac involvement, beyond biomarkers such as brain natriuretic peptide and troponin I. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Cavalcante, João L; Collier, Patrick; Plana, Juan C; Agler, Deborah; Thomas, James D; Marwick, Thomas H
2012-12-01
Longitudinal strain (LS) imaging is an important tool for the quantification of left ventricular function and deformation, but its assessment is challenging in the presence of echocardiographic contrast agents (CAs). The aim of this study was to test the hypothesis that destruction of microbubbles using high mechanical index (MI) could allow the measurement of LS. LS was measured using speckle strain (speckle-tracking LS [STLS]) and Velocity Vector Imaging (VVI) before and after CA administration in 30 consecutive patients. Low MI was used for left ventricular opacification and three-dimensional high MI for microbubble destruction. Four different settings were tested over 60 sec: (1) baseline LS without contrast, (2) LS after CA administration with low MI (0.3), (3) LS after CA administration with high MI (0.9), and (4) LS after microbubble destruction with high MI and three-dimensional imaging. Baseline feasibility of LS assessment (99.3% and 98.2% with STLS and VVI, respectively) was reduced after CA administration using STLS at low (69%, P < .0001) and high (95.4%, P = .0002) MI as well as with VVI (93.8%, P = .004, and 84.7%, P < .0001, respectively). STLS assessment was feasible with high MI after microbubble destruction (1.7% of uninterpretable segments vs 0.7%, P = .26) but not using VVI (7.2% vs 1.8%, P < .001). Regardless of which microbubbles or image settings were used, VVI was associated with significant variability and overestimation of global LS (for low MI, +4.7%, P < .01; for high MI, +3.3%, P < .001; for high MI after microbubble destruction, +1.3%, P = .04). LS assessment is most feasible without contrast. If a CA is necessary, the calculation of LS is feasible using the speckle-tracking method, if three-dimensional imaging is used as a tool for microbubble destruction 1 min after CA administration. Copyright © 2012. Published by Mosby, Inc.
Podgórski, Michał; Grzelak, Piotr; Kaczmarska, Magdalena; Polguj, Michał; Łukaszewski, Maciej; Stefańczyk, Ludomir
2018-02-01
Objective Arterial stiffening is an early marker of atherosclerosis that has a prognostic value for cardiovascular morbidity and mortality. Although many markers of arterial hardening have been proposed, the search is on for newer, more user-friendly and reliable surrogates. One such potential candidate has emerged from cardiology, the speckle-tracking technique. The aim of this study was to evaluate the feasibility of the two-dimensional speckle tracking for the evaluation of arterial wall stiffness in comparison with standard stiffness parameters. Methods Carotid ultrasound and applanation tonometry were performed in 188 patients with no cardiovascular risk factors. The following parameters were then evaluated: the intima-media complex thickness, distensibility coefficient, β-stiffness index, circumferential strain/strain rate, and pulse wave velocity and augmentation index. These variables were compared with each other and with patient age, and their reliability was assessed with Bland-Altman plots. Results Strain parameters derived from two-dimensional speckle tracking and intima-media complex thickness correlated better with age and pulse wave velocity than standard makers of arterial stiffness. Moreover, the reliability of these measurements was significantly higher than conventional surrogates. Conclusions Two-dimensional speckle tracing is a reliable method for the evaluation of arterial stiffness. Therefore, together with intima-media complex thickness measurement, it offers great potential in clinical practice as an early marker of atherosclerosis.
Domsik, Péter; Kalapos, Anita; Chadaide, Számi; Sepp, Róbert; Hausinger, Péter; Forster, Tamás; Nemes, Attila
2014-11-01
Hypertrophic cardiomyopathy (HCM) represents a generalized myopathic process affecting both ventricular and atrial myocardium. Reduced left atrial (LA) function was demonstrated in HCM by different methods. Three-dimensional (3D) speckle tracking echocardiography (STE) has just been introduced for the evaluation of LA. This study was designed to compare 3DSTE-derived LA volumetric and strain parameters in HCM with healthy controls. The study comprised 23 consecutive HCM patients (mean age: 48.5 ± 15.1 years, 14 men). Their results were compared to 23 age- and gender-matched healthy controls. Complete two-dimensional Doppler echocardiography and 3DSTE have been performed in all cases. Calculated LA maximum (66.4 ± 20.4 mL vs. 36.0 ± 6.1 mL, P < 0.0001) and minimum (39.2 ± 19.1 vs. 16.0 ± 4.6 mL, P < 0.0001) volumes and LA volume before atrial contraction (53.6 ± 19.9 vs. 24.0 ± 6.2 mL, P < 0.0001) were significantly increased in HCM patients. Atrial stroke volumes respecting cardiac cycles proved to be increased, while emptying fractions were decreased in subjects with HCM. Mean global radial (-12.2 ± 6.7% vs. -19.6 ± 11.7, P < 0.05), longitudinal (26.5 ± 16.5% vs. 29.8 ± 12.1%, P < 0.05) and 3D strain (-6.1 ± 4.4% vs. -12.5 ± 10.2%, P < 0.05) proved to be significantly reduced in HCM patients as compared with matched controls. Three-dimensional speckle tracking echocardiography allows detailed evaluation of LA (dys) function in HCM by volumetric and strain measurements. © 2014, Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Miyajo, Akira; Hasegawa, Hideyuki
2018-07-01
At present, the speckle tracking method is widely used as a two- or three-dimensional (2D or 3D) motion estimator for the measurement of cardiovascular dynamics. However, this method requires high-level interpolation of a function, which evaluates the similarity between ultrasonic echo signals in two frames, to estimate a subsample small displacement in high-frame-rate ultrasound, which results in a high computational cost. To overcome this problem, a 2D motion estimator using the 2D Fourier transform, which does not require any interpolation process, was proposed by our group. In this study, we compared the accuracies of the speckle tracking method and our method using a 2D motion estimator, and applied the proposed method to the measurement of motion of a human carotid arterial wall. The bias error and standard deviation in the lateral velocity estimates obtained by the proposed method were 0.048 and 0.282 mm/s, respectively, which were significantly better than those (‑0.366 and 1.169 mm/s) obtained by the speckle tracking method. The calculation time of the proposed phase-sensitive method was 97% shorter than the speckle tracking method. Furthermore, the in vivo experimental results showed that a characteristic change in velocity around the carotid bifurcation could be detected by the proposed method.
Fujiwara, Shohei; Komamura, Kazuo; Nakabo, Ayumi; Masaki, Mitsuru; Fukui, Miho; Sugahara, Masataka; Itohara, Kanako; Soyama, Yuko; Goda, Akiko; Hirotani, Shinichi; Mano, Toshiaki; Masuyama, Tohru
2016-02-01
Left ventricular (LV) dyssynchrony is a causal factor in LV dysfunction and thought to be associated with LV twisting motion. We tested whether three-dimensional speckle tracking (3DT) can be used to evaluate the relationship between LV twisting motion and dyssynchrony. We examined 25 patients with sick sinus syndrome who had received dual chamber pacemakers. The acute effects of ventricular pacing on LV wall motion after the switch from atrial to ventricular pacing were assessed. LV twisting motion and dyssynchrony during each pacing mode were measured using 3DT. LV dyssynchrony was calculated from the time to the minimum peak systolic area strain of 16 LV imaging segments. Ventricular pacing increased LV dyssynchrony and decreased twist and torsion. A significant correlation was observed between changes in LV dyssynchrony and changes in torsion (r = -0.65, p < 0.01). Evaluation of LV twisting motion can potentially be used for diagnosing LV dyssynchrony.
Vitarelli, Antonio; Barillà, Francesco; Capotosto, Lidia; D'Angeli, Ilaria; Truscelli, Giovanni; De Maio, Melissa; Ashurov, Rasul
2014-03-01
The aim of this study was to assess changes in right ventricular (RV) parameters determined by three-dimensional (3D) echocardiography and speckle-tracking echocardiography in patients with acute pulmonary embolism and RV dysfunction without systemic hypotension (submassive pulmonary embolism). Sixty-six patients were prospectively studied at the onset of the acute episode and after median follow-up periods of 30 days and 6 months. Sixty-six controls were selected. RV fractional area change, tricuspid annular plane systolic excursion, and myocardial performance index were determined. RV systolic pressure was assessed using continuous-wave Doppler echocardiography. Three-dimensional RV ejection fraction (RVEF) was calculated. Two-dimensional peak systolic RV longitudinal strain (RVLS) was measured in the basal free wall, mid free wall (MFW), and apical free wall and the septum. Tricuspid annular plane systolic excursion and fractional area change were smaller and myocardial performance index was larger compared with controls (P < .05). Global RVLS (P < .05), MFW RVLS (P < .001), and 3D RVEF (P < .001) were lower in patients with pulmonary embolism than in controls. There was earlier reversal of MFW RVLS values on 30-day follow-up and longer reversal of 3D RVEF and RV systolic pressure values at 6-month follow-up. Receiver operating characteristic curve analysis showed that changes in 3D RVEF and MFW RVLS were the most sensitive predictors of adverse events. By multivariate analysis, RV systolic pressure (P = .007), MFW RVLS (P = .002), and 3D RVEF (P = .001) were independently associated with adverse outcomes. Acute submassive pulmonary embolism has a significant impact on RV function as assessed by 3D echocardiography and speckle-tracking echocardiography. Decreases in MFW RVLS and 3D RVEF may persist during short-term and long-term follow-up and correlate with unfavorable outcomes. Copyright © 2014 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
Caspar, Thibault; Fichot, Marie; Ohana, Mickaël; El Ghannudi, Soraya; Morel, Olivier; Ohlmann, Patrick
2017-08-01
Acute myocarditis (AM) often involves the left ventricular (LV) subepicardium that might be displayed by cardiac magnetic resonance even late after the acute phase. In the absence of global or regional LV dysfunction, conventional transthoracic echocardiography (TTE) does not accurately identify tissue sequelae of AM. We sought to evaluate the diagnostic value of two-dimensional (2D) and three-dimensional (3D) speckle-tracking echocardiography to identify patients with a history of AM with preserved LV ejection fraction (LVEF). Fifty patients (group 1: age, 31.4 ± 10.5 years; 76% males) with a history of cardiac magnetic resonance-confirmed diagnosis of AM (according to the Lake Louise criteria) were retrospectively identified and then (21.7 ± 23.4 months later) evaluated by complete echocardiography including 2D and 3D speckle-tracking analysis, as well as 50 age- and gender-matched healthy controls (group 2: age, 31.2 ± 9.5 years: 76% males). Patients with a history of severe clinical presentation of AM (sudden death, ventricular arrhythmia, heart failure, alteration of LVEF) were excluded. At diagnosis, peak troponin and C-reactive protein were 11.97 (interquartile range, 4.52-25.92) μg/L and 32.3 (interquartile range, 14.85-70.45) mg/L, respectively. Mean delay between acute phase and follow-up study TTE was 21.7 ± 23.4 months. LVEF was not statistically different between groups (62.1% vs 63.5%, P = .099). Two-dimensional global longitudinal strain (GLS) was lower in magnitude in group 1 (-17.8% vs -22.1%, P < .0001) as were 2D layer-specific subepicardial GLS (-15.4% vs -19.7%, P < .0001) and subendocardial GLS (-20.71% vs -25.08%, P < .0001). Three-dimensional global longitudinal, circumferential, area, and radial strains were lower in magnitude in group 1 (-11.80% vs -14.98%, P < .0001; -12.57% vs -15.12%, P < .0001; -22.28% vs -25.87%, P < .0001; 31.47% vs 38.06%, P < .0001, respectively). Receiver operating characteristic curve analysis showed that subepicardial GLS displayed a better diagnostic performance to detect sequelae of AM as compared with GLS (area under the curve = 0.97 vs 0.93, P = .045). In patients with a history of AM, a subtle LV dysfunction can be detected by 2D and 3D speckle-tracking echocardiography, even though LVEF is conserved, adding incremental information over conventional TTE. Copyright © 2017 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Weber, Ulrike; Base, Eva; Ristl, Robin; Mora, Bruno
2015-08-01
Frequently used parameters for evaluation of left ventricular systolic function are load-sensitive. However, the impact of preload alterations on speckle-tracking echocardiographic parameters during anesthesia has not been validated. Therefore, two-dimensional (2D) speckle-tracking echocardiography radial strain (RS) was assessed during general anesthesia, simulating 3 different preload conditions. Single-center prospective observational study. University hospital. Thirty-three patients with normal left ventricular systolic function undergoing major surgery. Transgastric views of the midpapillary level of the left ventricle were acquired at 3 different positions. Fractional shortening (FS), fractional area change (FAC), and 2D speckle-tracking echocardiography RS were analyzed in the transgastric midpapillary view. Considerable correlation above 0.5 was found for FAC and FS in the zero and Trendelenburg positions (r = 0.629, r = 0.587), and for RS and FAC in the anti-Trendelenburg position (r = 0.518). In the repeated-measures analysis, significant differences among the values measured at the 3 positions were found for FAC and FS. For FAC, there were differences up to 2.8 percentage points between the anti-Trendelenburg position and the other 2 positions. For FS, only the difference between position zero and anti-Trendelenburg was significant, with an observed change of 1.66. Two-dimensional RS was not significantly different at all positions, with observed changes below 1 percentage point. Alterations in preload did not result in clinically relevant changes of RS, FS, or FAC. Observed changes for RS were smallest; however, the variation of RS was larger than that of FS or FAC. Copyright © 2015 Elsevier Inc. All rights reserved.
Revell, James; Mirmehdi, Majid; McNally, Donal
2005-06-01
We present the development and validation of an image based speckle tracking methodology, for determining temporal two-dimensional (2-D) axial and lateral displacement and strain fields from ultrasound video streams. We refine a multiple scale region matching approach incorporating novel solutions to known speckle tracking problems. Key contributions include automatic similarity measure selection to adapt to varying speckle density, quantifying trajectory fields, and spatiotemporal elastograms. Results are validated using tissue mimicking phantoms and in vitro data, before applying them to in vivo musculoskeletal ultrasound sequences. The method presented has the potential to improve clinical knowledge of tendon pathology from carpel tunnel syndrome, inflammation from implants, sport injuries, and many others.
Dictionary learning-based spatiotemporal regularization for 3D dense speckle tracking
NASA Astrophysics Data System (ADS)
Lu, Allen; Zontak, Maria; Parajuli, Nripesh; Stendahl, John C.; Boutagy, Nabil; Eberle, Melissa; O'Donnell, Matthew; Sinusas, Albert J.; Duncan, James S.
2017-03-01
Speckle tracking is a common method for non-rigid tissue motion analysis in 3D echocardiography, where unique texture patterns are tracked through the cardiac cycle. However, poor tracking often occurs due to inherent ultrasound issues, such as image artifacts and speckle decorrelation; thus regularization is required. Various methods, such as optical flow, elastic registration, and block matching techniques have been proposed to track speckle motion. Such methods typically apply spatial and temporal regularization in a separate manner. In this paper, we propose a joint spatiotemporal regularization method based on an adaptive dictionary representation of the dense 3D+time Lagrangian motion field. Sparse dictionaries have good signal adaptive and noise-reduction properties; however, they are prone to quantization errors. Our method takes advantage of the desirable noise suppression, while avoiding the undesirable quantization error. The idea is to enforce regularization only on the poorly tracked trajectories. Specifically, our method 1.) builds data-driven 4-dimensional dictionary of Lagrangian displacements using sparse learning, 2.) automatically identifies poorly tracked trajectories (outliers) based on sparse reconstruction errors, and 3.) performs sparse reconstruction of the outliers only. Our approach can be applied on dense Lagrangian motion fields calculated by any method. We demonstrate the effectiveness of our approach on a baseline block matching speckle tracking and evaluate performance of the proposed algorithm using tracking and strain accuracy analysis.
Dedicated ultrasound speckle tracking to study tendon displacement
NASA Astrophysics Data System (ADS)
Korstanje, Jan-Wiebe H.; Selles, Ruud W.; Stam, Henk J.; Hovius, Steven E. R.; Bosch, Johan G.
2009-02-01
Ultrasound can be used to study tendon and muscle movement. However, quantization is mostly based on manual tracking of anatomical landmarks such as the musculotendinous junction, limiting the applicability to a small number of muscle-tendon units. The aim of this study is to quantify tendon displacement without employing anatomical landmarks, using dedicated speckle tracking in long B-mode image sequences. We devised a dedicated two-dimensional multikernel block-matching scheme with subpixel accuracy to handle large displacements over long sequences. Images were acquired with a Philips iE33 with a 7 MHz linear array and a VisualSonics Vevo 770 using a 40 MHz mechanical probe. We displaced the flexor digitorum superficialis of two pig cadaver forelegs with three different velocities (4,10 and 16 mm/s) over 3 distances (5, 10, 15 mm). As a reference, we manually determined the total displacement of an injected hyperechogenic bullet in the tendons. We automatically tracked tendon parts with and without markers and compared results to the true displacement. Using the iE33, mean tissue displacement underestimations for the three different velocities were 2.5 +/- 1.0%, 1.7 +/- 1.1% and 0.7 +/- 0.4%. Using the Vevo770, mean tissue displacement underestimations were 0.8 +/- 1.3%, 0.6 +/- 0.3% and 0.6 +/- 0.3%. Marker tracking displacement underestimations were only slightly smaller, showing limited tracking drift for non-marker tendon tissue as well as for markers. This study showed that our dedicated speckle tracking can quantify extensive tendon displacement with physiological velocities without anatomical landmarks with good accuracy for different types of ultrasound configurations. This technique allows tracking of a much larger range of muscle-tendon units than by using anatomical landmarks.
Sun, Lihua; Wang, Ying; Dong, Yu; Song, Shengda; Luo, Runlan; Li, Guangsen
2018-02-26
To assess right atrium (RA) function of patients with systemic lupus erythematosus (SLE) and pulmonary artery hypertension (PAH) by 2-dimensional speckle-tracking echocardiography. Thirty matched healthy adults were selected as group A. Then, 102 patients with SLE were divided into 3 groups according to the severity of PAH. Group B included 37 patients without PAH (pulmonary artery [PA] systolic pressure ≤ 30 mm Hg); group C included 34 patients with PAH (PA systolic pressure of 30-50 mm Hg); and group D included 31 patients with PAH (PA systolic pressure ≥ 50 mm Hg). Parameters evaluated included RA maximum volume, minimum volume, preatrial contraction volume, passive ejection fraction (EF), and active EF. The global peak longitudinal systolic strain rate and early and late diastolic strain rates of the RA were obtained by 2-dimensional speckle-tracking echocardiography. No significant differences were found in all parameters between groups B and A (P > .05). The RA maximum volume, minimum volume, preatrial contraction volume, active EF, and late diastolic strain rate in groups C and D were significantly increased compared with those in groups A and B, and the parameters in group D were significantly higher than those in group C (P < .05). Although the RA passive EF, early diastolic strain rate, and systolic strain rate in groups C and D were significantly decreased compared with those in groups A and B, those in group D were significantly lower than those in group C (P < .05). Two-dimensional speckle-tracking echocardiography could effectively assess RA function in patients with SLE who have different severities of PAH. © 2018 by the American Institute of Ultrasound in Medicine.
Visentin, Silvia; Palermo, Chiara; Camerin, Martina; Daliento, Luciano; Muraru, Denisa; Cosmi, Erich; Badano, Luigi P
2017-01-01
Cardiovascular diseases (CVD) represent the leading cause of maternal mortality and morbidity. Knowledge of CVD in women is constantly evolving and data are emerging that female-specific risk factors as complications of pregnancy are conditions associated with an increased risk for the long-term development of CVD. Echocardiography is a safe and effective imaging technique indicated in symptomatic or asymptomatic pregnant women with congenital heart diseases who require close monitoring of cardiac function. Deformation imaging is an echocardiographic technique used to assess myocardial function by measuring the actual deformation of the myocardium through the cardiac cycle. Speckle-tracking echocardiography (STE) is a two-dimensional (2D) technique which has been found to be more accurate than tissue Doppler to assess both left ventricular (LV) and right ventricular (RV) myocardial function. The use of 2D STE however might present some technical issues due to the tomographic nature of the technique and the motion in the three-dimensional space of the myocardial speckles. This has promoted the use of 3D STE to track the motion of the speckles in the 3D space. This review will focus on the clinical value of the new echocardiographic techniques of deformation imaging used to assess the maternal cardiovascular system in complicated pregnancies.
X-ray phase contrast tomography by tracking near field speckle
Wang, Hongchang; Berujon, Sebastien; Herzen, Julia; Atwood, Robert; Laundy, David; Hipp, Alexander; Sawhney, Kawal
2015-01-01
X-ray imaging techniques that capture variations in the x-ray phase can yield higher contrast images with lower x-ray dose than is possible with conventional absorption radiography. However, the extraction of phase information is often more difficult than the extraction of absorption information and requires a more sophisticated experimental arrangement. We here report a method for three-dimensional (3D) X-ray phase contrast computed tomography (CT) which gives quantitative volumetric information on the real part of the refractive index. The method is based on the recently developed X-ray speckle tracking technique in which the displacement of near field speckle is tracked using a digital image correlation algorithm. In addition to differential phase contrast projection images, the method allows the dark-field images to be simultaneously extracted. After reconstruction, compared to conventional absorption CT images, the 3D phase CT images show greatly enhanced contrast. This new imaging method has advantages compared to other X-ray imaging methods in simplicity of experimental arrangement, speed of measurement and relative insensitivity to beam movements. These features make the technique an attractive candidate for material imaging such as in-vivo imaging of biological systems containing soft tissue. PMID:25735237
Wang, Qingqing; Ma, Wenyan; Xia, Jizhu
2018-01-24
The aim of this study was to detect left ventricular (LV) structure and function abnormalities in patients with type 2 diabetes mellitus with or without nonalcoholic fatty liver (NAFL) using 3-dimensional speckle-tracking echocardiography. Eighty patients with type 2 diabetes and a normal LV ejection fraction (≥55%), including 40 with coexistent NAFL, and 40 age- and sex-matched control participants were recruited. Conventional echocardiography and 3-dimensional speckle-tracking echocardiography were performed, and global longitudinal strain, global circumferential strain, global area strain, and global radial strain values were measured. Significant differences in 2-dimensional LV functional patterns were found among the 3 groups (P = .031), and LV hypertrophy was the most prevalent in patients with diabetes and NAFL. The patients with diabetes only had significantly lower global longitudinal strain, global circumferential strain, and global radial strain than the controls (all P < .05). The patients with diabetes and NAFL had severely lower global longitudinal strain, global circumferential strain, global area strain, and global radial strain than the controls (all P < .001), and they also had severely lower global longitudinal strain, global area strain, and global radial strain than the patients with diabetes only (all P < 0.001). The hemoglobin A 1c level and NAFL were independently associated with strain values in all patients with diabetes. The strain values in multiple directions (≥2 of global longitudinal, global circumferential, global area, and global radial strain) decreased significantly in the patients with diabetes and moderate and severe NAFL compared to those with mild NAFL (all P < .05). Nonalcoholic fatty liver could aggravate LV hypertrophy and dysfunction in patients with type 2 diabetes. The combined application of conventional and 3-dimensional speckle-tracking echocardiography could detect these asymptomatic preclinical abnormalities. © 2018 by the American Institute of Ultrasound in Medicine.
Varma, Hari M.; Valdes, Claudia P.; Kristoffersen, Anna K.; Culver, Joseph P.; Durduran, Turgut
2014-01-01
A novel tomographic method based on the laser speckle contrast, speckle contrast optical tomography (SCOT) is introduced that allows us to reconstruct three dimensional distribution of blood flow in deep tissues. This method is analogous to the diffuse optical tomography (DOT) but for deep tissue blood flow. We develop a reconstruction algorithm based on first Born approximation to generate three dimensional distribution of flow using the experimental data obtained from tissue simulating phantoms. PMID:24761306
Two-dimensional speckle tracking cardiac mechanics and constrictive pericarditis: systematic review.
Madeira, Marta; Teixeira, Rogério; Costa, Marco; Gonçalves, Lino; Klein, Allan L
2016-10-01
Transthoracic echocardiography has a pivotal role in the diagnosis of constrictive pericarditis (CP). In addition to the classic M-mode, two-dimensional and Doppler indices, newer methodologies designed to evaluate myocardial mechanics, such as two-dimensional speckle tracking echocardiography (2DSTE), provide additional diagnostic and clinical information in the context of CP. Research has demonstrated that cardiac mechanics can improve echocardiographic diagnostic accuracy of CP and aid in differentiating between constrictive and restrictive ventricular physiology. 2DSTE can also be used to assess the success of pericardiectomy and its impact on atrial and ventricular mechanics. In the course of this review, we describe cardiac mechanics in patients with CP and summarize the influence of pericardiectomy on atrial and ventricular mechanics assessed using 2DSTE. © 2016, Wiley Periodicals, Inc.
Harada, Kenji; Mori, Kazuhiro; Ichimiya, Chiyo; Terada, Naho; Iima, Tsutomu; Harada, Takafumi; Fujisawa, Kazutoshi; Kawata, Atsushi; Okada, Ayumi; Yamamoto, Hirofumi; Fujinaga, Hiroyuki
2017-05-01
Double-chambered left ventricle (DCLV) is a particularly rare congenital entity characterized by the presence of two ventricular cavities separated by an abnormal muscle band. An asymptomatic 15-year-old boy was referred to our hospital because of electrocardiographic (ECG) abnormalities. His initial transthoracic echocardiography (TTE) demonstrated a DCLV with mild left ventricular systolic dysfunction. During a 5-year follow-up period, he remained symptom free with no changes in ECG and conventional TTE findings. However, two-dimensional speckle tracking echocardiography revealed a subtle progressive deterioration of left ventricular systolic function during the 5-year follow-up. © 2017, Wiley Periodicals, Inc.
Shunt flow evaluation in congenital heart disease based on two-dimensional speckle tracking.
Fadnes, Solveig; Nyrnes, Siri Ann; Torp, Hans; Lovstakken, Lasse
2014-10-01
High-frame-rate ultrasound speckle tracking was used for quantification of peak velocity in shunt flows resulting from septal defects in congenital heart disease. In a duplex acquisition scheme implemented on a research scanner, unfocused transmit beams and full parallel receive beamforming were used to achieve a frame rate of 107 frames/s for full field-of-view flow images with high accuracy, while also ensuring high-quality focused B-mode tissue imaging. The setup was evaluated in vivo for neonates with atrial and ventricular septal defects. The shunt position was automatically tracked in B-mode images and further used in blood speckle tracking to obtain calibrated shunt flow velocities throughout the cardiac cycle. Validation toward color flow imaging and pulsed wave Doppler with manual angle correction indicated that blood speckle tracking could provide accurate estimates of shunt flow velocities. The approach was less biased by clutter filtering compared with color flow imaging and was able to provide velocity estimates beyond the Nyquist range. Possible placements of sample volumes (and angle corrections) for conventional Doppler resulted in a peak shunt velocity variations of 0.49-0.56 m/s for the ventricular septal defect of patient 1 and 0.38-0.58 m/s for the atrial septal defect of patient 2. In comparison, the peak velocities found from speckle tracking were 0.77 and 0.33 m/s for patients 1 and 2, respectively. Results indicated that complex intraventricular flow velocity patterns could be quantified using high-frame-rate speckle tracking of both blood and tissue movement. This could potentially help increase diagnostic accuracy and decrease inter-observer variability when measuring peak velocity in shunt flows. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Sokalskis, Vladislavs; Peluso, Diletta; Jagodzinski, Annika; Sinning, Christoph
2017-06-01
Right heart dysfunction has been found to be a strong prognostic factor predicting adverse outcome in various cardiopulmonary diseases. Conventional echocardiographic measurements can be limited by geometrical assumptions and impaired reproducibility. Speckle tracking-derived strain provides a robust quantification of right ventricular function. It explicitly evaluates myocardial deformation, as opposed to tissue Doppler-derived strain, which is computed from tissue velocity gradients. Right ventricular longitudinal strain provides a sensitive tool for detecting right ventricular dysfunction, even at subclinical levels. Moreover, the longitudinal strain can be applied for prognostic stratification of patients with pulmonary hypertension, pulmonary embolism, and congestive heart failure. Speckle tracking-derived right atrial strain, right ventricular longitudinal strain-derived mechanical dyssynchrony, and three-dimensional echocardiography-derived strain are emerging imaging parameters and methods. Their application in research is paving the way for their clinical use. © 2017, Wiley Periodicals, Inc.
Jiang, Jingfeng; Hall, Timothy J
2011-04-01
A hybrid approach that inherits both the robustness of the regularized motion tracking approach and the efficiency of the predictive search approach is reported. The basic idea is to use regularized speckle tracking to obtain high-quality seeds in an explorative search that can be used in the subsequent intelligent predictive search. The performance of the hybrid speckle-tracking algorithm was compared with three published speckle-tracking methods using in vivo breast lesion data. We found that the hybrid algorithm provided higher displacement quality metric values, lower root mean squared errors compared with a locally smoothed displacement field, and higher improvement ratios compared with the classic block-matching algorithm. On the basis of these comparisons, we concluded that the hybrid method can further enhance the accuracy of speckle tracking compared with its real-time counterparts, at the expense of slightly higher computational demands. © 2011 IEEE
Karsenty, Clement; Hadeed, Khaled; Dulac, Yves; Semet, Florent; Alacoque, Xavier; Breinig, Sophie; Leobon, Bertrand; Acar, Philippe; Hascoet, Sebastien
2017-03-01
Right ventricular (RV) function is a prognostic marker of cardiac disease in children. Speckle tracking has been developed to assess RV longitudinal shortening, the dominant deformation during systole; little is known about its feasibility in children with congenital heart disease (CHD). To evaluate the feasibility and reproducibility of RV two-dimensional (2D) strain assessed by speckle tracking in infants undergoing CHD surgery compared with conventional markers. In this prospective single-centre study, RV peak systolic strain (RV-PSS) was measured using 2D speckle tracking in 37 consecutive children undergoing CHD surgery. Examinations were performed the day before surgery, a few hours after surgery and before discharge. Relationships with the z score of tricuspid annular plane systolic excursion (TAPSE) and tricuspid annular systolic velocity (TA Sa) were assessed. Median (interquartile range) age was 19 months (5-63); median weight was 9.2 kg (5.3-18.0). RV-PSS analysis was feasible in 92.9% (95% confidence interval [CI]: 86.0-97.1) of examinations. The coefficient of variation was 9.7% (95% CI: 7.4-11.9) for intraobserver variability and 15.1% (95% CI: 12.7-17.6) for interobserver variability. Correlations between RV-PSS and z score of TAPSE and TA Sa were strong (r=0.71, P<0.0001 and r=0.70, P<0.0001, respectively). RV-PSS was significantly reduced after surgery compared with baseline (-10.5±2.9% vs. -19.5±4.8%; P<0.0001) and at discharge (-13.5±4.0% vs. -19.5±4.8%; P<0.0001). Similar evolutions were observed with TAPSE and TA Sa (both P<0.0001). RV longitudinal strain by speckle tracking is a feasible and reproducible method of assessing perioperative evolution of RV function in children with CHD. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Three Dimensional Imaging with Multiple Wavelength Speckle Interferometry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernacki, Bruce E.; Cannon, Bret D.; Schiffern, John T.
2014-05-28
We present the design, modeling, construction, and results of a three-dimensional imager based upon multiple-wavelength speckle interferometry. A surface under test is illuminated with tunable laser light in a Michelson interferometer configuration while a speckled image is acquired at each laser frequency step. The resulting hypercube is Fourier transformed in the frequency dimension and the beat frequencies that result map the relative offsets of surface features. Synthetic wavelengths resulting from the laser tuning can probe features ranging from 18 microns to hundreds of millimeters. Three dimensional images will be presented along with modeling results.
Suzuki, Ryohei; Mochizuki, Yohei; Yoshimatsu, Hiroki; Teshima, Takahiro; Matsumoto, Hirotaka; Koyama, Hidekazu
2017-12-01
Objectives Hypertrophic cardiomyopathy, a primary disorder of the myocardium, is the most common cardiac disease in cats. However, determination of myocardial deformation with two-dimensional speckle-tracking echocardiography in cats with various stages of hypertrophic cardiomyopathy has not yet been reported. This study was designed to measure quantitatively multidirectional myocardial deformations of cats with hypertrophic cardiomyopathy. Methods Thirty-two client-owned cats with hypertrophic cardiomyopathy and 14 healthy cats serving as controls were enrolled and underwent assessment of myocardial deformation (peak systolic strain and strain rate) in the longitudinal, radial and circumferential directions. Results Longitudinal and radial deformations were reduced in cats with hypertrophic cardiomyopathy, despite normal systolic function determined by conventional echocardiography. Cats with severely symptomatic hypertrophic cardiomyopathy also had lower peak systolic circumferential strain, in addition to longitudinal and radial strain. Conclusions and relevance Longitudinal and radial deformation may be helpful in the diagnosis of hypertrophic cardiomyopathy. Additionally, the lower circumferential deformation in cats with severe hypertrophic cardiomyopathy may contribute to clinical findings of decompensation, and seems to be related to severe cardiac clinical signs. Indices of multidirectional myocardial deformations by two-dimensional speckle-tracking echocardiography may be useful markers and help to distinguish between cats with hypertrophic cardiomyopathy and healthy cats. Additionally, they may provide more detailed assessment of contractile function in cats with hypertrophic cardiomyopathy.
Hayashi, Shuji; Yamada, Hirotsugu; Bando, Mika; Saijo, Yoshihito; Nishio, Susumu; Hirata, Yukina; Klein, Allan L; Sata, Masataka
2015-08-01
Left atrial (LA) strain analysis using speckle tracking echocardiography is useful for assessing LA function. However, there is no established procedure for this method. Most investigators have determined the electrocardiographic R-wave peak as the starting point for LA strain analysis. To test our hypothesis that P-wave onset should be used as the starting point, we measured LA strain using 2 different starting points and compared the strain values with the corresponding LA volume indices obtained by three-dimensional (3D) echocardiography. We enrolled 78 subjects (61 ± 17 years, 25 males) with and without various cardiac diseases in this study and assessed global longitudinal LA strain by two-dimensional speckle tracking strain echocardiography using EchoPac software. We used either R-wave peak or P-wave onset as the starting point for determining LA strains during the reservoir (Rres, Pres), conduit (Rcon, Pcon), and booster pump (Rpump, Ppump) phases. We determined the maximum, minimum, and preatrial contraction LA volumes, and calculated the LA total, passive, and active emptying fractions using 3D echocardiography. The correlation between Pres and LA total emptying fraction was better than the correlation between Rres and LA total emptying fraction (r = 0.458 vs. 0.308, P = 0.026). Pcon and Ppump exhibited better correlation with the corresponding 3D echocardiographic parameters than Rcon (r = 0.560 vs. 0.479, P = 0.133) and Rpump (r = 0.577 vs. 0.345, P = 0.003), respectively. LA strain in any phase should be analyzed using P-wave onset as the starting point rather than R-wave peak. © 2014, Wiley Periodicals, Inc.
Tarascio, Michela; Leo, Laura Anna; Klersy, Catherine; Murzilli, Romina; Moccetti, Tiziano; Faletra, Francesco Fulvio
2017-07-01
Identification of the extent of scar transmurality in chronic ischemic heart disease is important because it correlates with viability. The aim of this retrospective study was to evaluate whether layer-specific two-dimensional speckle-tracking echocardiography allows distinction of scar presence and transmurality. A total of 70 subjects, 49 with chronic ischemic cardiomyopathy and 21 healthy subjects, underwent two-dimensional speckle-tracking echocardiography and late gadolinium-enhanced cardiac magnetic resonance. Scar extent was determined as the relative amount of hyperenhancement using late gadolinium-enhanced cardiac magnetic resonance in an 18-segment model (0% hyperenhancement = normal; 1%-50% = subendocardial scar; 51%-100% = transmural scar). In the same 18-segment model, peak systolic circumferential strain and longitudinal strain were calculated separately for the endocardial and epicardial layers as well as the full-wall myocardial thickness. All strain parameters showed cutoff values (area under the curve > 0.69) that allowed the discrimination of normal versus scar segments but not of transmural versus subendocardial scars. This was true for all strain parameters analyzed, without differences in efficacy between longitudinal and circumferential strain and subendocardial, subepicardial, and full-wall-thickness strain values. Circumferential and longitudinal strain in normal segments showed transmural and basoapical gradients (greatest values at the subendocardial layer and apex). In segments with scar, transmural gradient was maintained, whereas basoapical gradient was lost because the reduction of strain values in the presence of the scar was greater at the apex. The two-dimensional speckle-tracking echocardiographic values distinguish scar presence but not transmurality; thus, they are not useful predictors of scar segment viability. It remains unclear why there is a greater strain value reduction in the presence of a scar at the apical level. Copyright © 2017 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Enzensberger, Christian; Achterberg, Friederike; Graupner, Oliver; Wolter, Aline; Herrmann, Johannes; Axt-Fliedner, Roland
2017-06-01
Frame rates (FR) used for strain analysis assessed by speckle tracking in fetal echocardiography show a considerable variation. The aim of this study was to investigate the influence of the FR on strain analysis in 2D speckle tracking. Fetal echocardiography was performed prospectively on a Toshiba Aplio 500 system and a Toshiba Artida system, respectively. Based on an apical or basal four-chamber view of the fetal heart, cine loops were stored with a FR of 30 fps (Aplio 500) and 60 fps (Artida/Aplio 500). For both groups (30fps and 60fps), global and segmental longitudinal peak systolic strain (LPSS) values of both, left (LV) and right ventricle (RV), were assessed by 2D wall-motion tracking. A total of 101 fetuses, distributed to three study groups, were included. The mean gestational age was 25.2±5.0 weeks. Mean global LPSS values for RV in the 30 fps group and in the 60 fps group were -16.07% and -16.47%, respectively. Mean global LPSS values for LV in the 30 fps group and in the 60 fps group were -17.54% and -17.06%, respectively. Comparing global and segmental LPSS values of both, the RV and LV, did not show any statistically significant differences within the two groups. Performance of myocardial 2D strain analysis by wall-motion tracking was feasible with 30 and 60 fps. Obtained global and segmental LPSS values of both ventricles were relatively independent from acquisition rate. © 2017, Wiley Periodicals, Inc.
Wang, Qiushuang; Huang, Dangsheng; Zhang, Liwei; Shen, Dong; Ouyang, Qiaohong; Duan, Zhongxiang; An, Xiuzhi; Zhang, Meiqing; Zhang, Chunhong; Yang, Feifei; Zhi, Guang
2015-10-01
To compare three-dimensional (3D) and two-dimensional (2D) speckle tracking echocardiography (STE) techniques in the assessment of left ventricular function and myocardial infarct size (MIS). Thirty-two patients diagnosed with ST elevation myocardial infarction and 18 healthy control patients underwent 2D echocardiography, 3D echocardiography, and single photon emission computed tomography (SPECT). 3D left ventricular global area strain (GAS), 2D and 3D global longitudinal strain (GLS), global radial strain (GRS) as well as global circumferential strain (GCS) were analyzed to correlate with myocardial infarct size detected by SPECT. 2D and 3D left ventricular ejection fraction (LVEF) as well as 2D and 3D wall motion score index (WMSI) also were measured using conventional echocardiography. The 2D-GLS values were significantly higher than that of 3D-GLS, while 2D-GCS and GRS were significantly lower than 3D-GCS and GRS, respectively. However, no significant differences in LVEF and WMSI could be observed between 2D and 3D echocardiography. Myocardial strain indices, LVEF, and WMSI using 2D and 3D echocardiography also had good correlations with MIS as measured by SPECT. ROC curve analysis showed that the 3D and 2D myocardial indices, LVEF, and WMSI could distinguish between small and large MIS, while 2D-GLS had the highest AUC. The 2D and 3D myocardial strain indices correlated well with MIS by SPECT. Among them, the 2D-GLS showed the highest diagnostic value, while 3D-GRS and GCS had better diagnostic value than 2D-GRS and GCS. © 2015, Wiley Periodicals, Inc.
Influence of ultrasound speckle tracking strategies for motion and strain estimation.
Curiale, Ariel H; Vegas-Sánchez-Ferrero, Gonzalo; Aja-Fernández, Santiago
2016-08-01
Speckle Tracking is one of the most prominent techniques used to estimate the regional movement of the heart based on ultrasound acquisitions. Many different approaches have been proposed, proving their suitability to obtain quantitative and qualitative information regarding myocardial deformation, motion and function assessment. New proposals to improve the basic algorithm usually focus on one of these three steps: (1) the similarity measure between images and the speckle model; (2) the transformation model, i.e. the type of motion considered between images; (3) the optimization strategies, such as the use of different optimization techniques in the transformation step or the inclusion of structural information. While many contributions have shown their good performance independently, it is not always clear how they perform when integrated in a whole pipeline. Every step will have a degree of influence over the following and hence over the final result. Thus, a Speckle Tracking pipeline must be analyzed as a whole when developing novel methods, since improvements in a particular step might be undermined by the choices taken in further steps. This work presents two main contributions: (1) We provide a complete analysis of the influence of the different steps in a Speckle Tracking pipeline over the motion and strain estimation accuracy. (2) The study proposes a methodology for the analysis of Speckle Tracking systems specifically designed to provide an easy and systematic way to include other strategies. We close the analysis with some conclusions and recommendations that can be used as an orientation of the degree of influence of the models for speckle, the transformation models, interpolation schemes and optimization strategies over the estimation of motion features. They can be further use to evaluate and design new strategy into a Speckle Tracking system. Copyright © 2016 Elsevier B.V. All rights reserved.
Curiale, Ariel H; Vegas-Sánchez-Ferrero, Gonzalo; Bosch, Johan G; Aja-Fernández, Santiago
2015-08-01
The strain and strain-rate measures are commonly used for the analysis and assessment of regional myocardial function. In echocardiography (EC), the strain analysis became possible using Tissue Doppler Imaging (TDI). Unfortunately, this modality shows an important limitation: the angle between the myocardial movement and the ultrasound beam should be small to provide reliable measures. This constraint makes it difficult to provide strain measures of the entire myocardium. Alternative non-Doppler techniques such as Speckle Tracking (ST) can provide strain measures without angle constraints. However, the spatial resolution and the noisy appearance of speckle still make the strain estimation a challenging task in EC. Several maximum likelihood approaches have been proposed to statistically characterize the behavior of speckle, which results in a better performance of speckle tracking. However, those models do not consider common transformations to achieve the final B-mode image (e.g. interpolation). This paper proposes a new maximum likelihood approach for speckle tracking which effectively characterizes speckle of the final B-mode image. Its formulation provides a diffeomorphic scheme than can be efficiently optimized with a second-order method. The novelty of the method is threefold: First, the statistical characterization of speckle generalizes conventional speckle models (Rayleigh, Nakagami and Gamma) to a more versatile model for real data. Second, the formulation includes local correlation to increase the efficiency of frame-to-frame speckle tracking. Third, a probabilistic myocardial tissue characterization is used to automatically identify more reliable myocardial motions. The accuracy and agreement assessment was evaluated on a set of 16 synthetic image sequences for three different scenarios: normal, acute ischemia and acute dyssynchrony. The proposed method was compared to six speckle tracking methods. Results revealed that the proposed method is the most accurate method to measure the motion and strain with an average median motion error of 0.42 mm and a median strain error of 2.0 ± 0.9%, 2.1 ± 1.3% and 7.1 ± 4.9% for circumferential, longitudinal and radial strain respectively. It also showed its capability to identify abnormal segments with reduced cardiac function and timing differences for the dyssynchrony cases. These results indicate that the proposed diffeomorphic speckle tracking method provides robust and accurate motion and strain estimation. Copyright © 2015. Published by Elsevier B.V.
Current Status of 3-Dimensional Speckle Tracking Echocardiography: A Review from Our Experiences
Ishizu, Tomko; Aonuma, Kazutaka
2014-01-01
Cardiac function analysis is the main focus of echocardiography. Left ventricular ejection fraction (LVEF) has been the clinical standard, however, LVEF is not enough to investigate myocardial function. For the last decade, speckle tracking echocardiography (STE) has been the novel clinical tool for regional and global myocardial function analysis. However, 2-dimensional imaging methods have limitations in assessing 3-dimensional (3D) cardiac motion. In contrast, 3D echocardiography also has been widely used, in particular, to measure LV volume measurements and assess valvular diseases. Joining the technology bandwagon, 3D-STE was introduced in 2008. Experimental studies and clinical investigations revealed the reliability and feasibility of 3D-STE-derived data. In addition, 3D-STE provides a novel deformation parameter, area change ratio, which have the potential for more accurate assessment of overall and regional myocardial function. In this review, we introduced the features of the methodology, validation, and clinical application of 3D-STE based on our experiences for 7 years. PMID:25031794
Seo, Joonho; Koizumi, Norihiro; Funamoto, Takakazu; Sugita, Naohiko; Yoshinaka, Kiyoshi; Nomiya, Akira; Homma, Yukio; Matsumoto, Yoichiro; Mitsuishi, Mamoru
2011-06-01
Applying ultrasound (US)-guided high-intensity focused ultrasound (HIFU) therapy for kidney tumours is currently very difficult, due to the unclearly observed tumour area and renal motion induced by human respiration. In this research, we propose new methods by which to track the indistinct tumour area and to compensate the respiratory tumour motion for US-guided HIFU treatment. For tracking indistinct tumour areas, we detect the US speckle change created by HIFU irradiation. In other words, HIFU thermal ablation can coagulate tissue in the tumour area and an intraoperatively created coagulated lesion (CL) is used as a spatial landmark for US visual tracking. Specifically, the condensation algorithm was applied to robust and real-time CL speckle pattern tracking in the sequence of US images. Moreover, biplanar US imaging was used to locate the three-dimensional position of the CL, and a three-actuator system drives the end-effector to compensate for the motion. Finally, we tested the proposed method by using a newly devised phantom model that enables both visual tracking and a thermal response by HIFU irradiation. In the experiment, after generation of the CL in the phantom kidney, the end-effector successfully synchronized with the phantom motion, which was modelled by the captured motion data for the human kidney. The accuracy of the motion compensation was evaluated by the error between the end-effector and the respiratory motion, the RMS error of which was approximately 2 mm. This research shows that a HIFU-induced CL provides a very good landmark for target motion tracking. By using the CL tracking method, target motion compensation can be realized in the US-guided robotic HIFU system. Copyright © 2011 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Kercheva, M.; Ryabova, T.; Ryabov, V.; Karpov, R.
2015-11-01
The aim of this study was to assess the intraobserver reproducibility of parameters of standard and 2 dimensional speckle tracking echocardiography, dynamics of global longitudinal strain in patients with acute primary anterior STEMI. The study included 24 patients, mean age 58.46±10.2. Echocardiography with 2D speckle tracking imaging was performed on the 1st (T1), 7th (T2), 14th days (T3) after STEMI («Vivid E9»). Analysis of echocardiographic images was performed offline at the different periods by the two independent observers (EchoPac) - experienced and inexperienced. In order to assess the agreement between standard and 2D speckle tracking echocardiography, a correlation analysis (Pearson correlation, Spearman's rank correlation coefficient) and Bland-Altman analysis were undertaken. The 23 patients had urgent reperfusion therapy, 6 patients underwent primary PCI, 16 patients - PCI after successful fibrinolysis (68%). GLS and WMSI had the best intraobsever reproducibility. Dynamics of EDV LV, ESV LV, EF LV was without significant differences. Nevertheless, it was found positive dynamic of GLS: - 12.65±3.53 (T1), -13.61±3.81 (T2), -14.27±4.1 (T3), p<0.05. GLS reduced 11.35% (p=0.0048) from T1 to T3. The best intraobserver reproducibility of parameters of 2 D speckle-tracking and standard echocardiography was revealed in GLS and WMSI. The modern management of STEMI patients limits adverse postinfarction remodeling and preserves of global left ventricular contractility detected by the EF LV. However, GLS had the positive dynamics and improved to the 14th day.
Fukuda, Yuko; Tanaka, Hidekazu; Ryo-Koriyama, Keiko; Motoji, Yoshiki; Sano, Hiroyuki; Shimoura, Hiroyuki; Ooka, Junichi; Toki, Hiromi; Sawa, Takuma; Mochizuki, Yasuhide; Matsumoto, Kensuke; Emoto, Noriaki; Hirata, Ken-Ichi
2016-07-01
Right ventricular (RV) systolic function is one of the most important determinants of outcome for pulmonary hypertension (PH) patients, but the factors influencing prognosis vary widely. Elevated right atrial (RA) pressure is reported to be one of these prognostic factors, but its functional importance has scarcely been assessed. Eighty-two PH patients, all of whom underwent echocardiography and right heart catheterization, were recruited. RV function was assessed by two-dimensional speckle tracking longitudinal strain from RV-focused apical four-chamber view and calculated by averaging the three regional peak strains from the RV free wall (RV-free). RA function was determined as the sum of three peak strain values comprising reservoir, conduit, and contractile function (sum of RA strain). Sum of RA strain correlated significantly with hemodynamic parameters such as mean right atrial pressure (r = -0.35, P = 0.002) and end-diastolic RV pressure (r = -0.29, P = 0.008). Patients with sum of RA strain ≥30.2% experienced more favorable outcomes than those with sum of RA strain <30.2% (log-rank P = 0.001). Furthermore, patients with impaired RV systolic function (RV-free <20%) and RA function (sum of RA strain <30.2%) showed the worst outcome (P = 0.001). A sequential Cox model based on clinical variables (χ(2) = 5.8) was improved by addition of RV-free (χ(2) = 8.7; P < 0.05) and further improved by addition of sum of RA strain (χ(2) = 12.0; P < 0.01). Right atrial strain appears to be a valuable additive factor for predicting outcomes for PH patients, and comprehensive functional assessment of right-sided heart using speckle tracking strain may have potential clinical implications for better management of PH patients. © 2016, Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Sun, Feng-Rong; Wang, Xiao-Jing; Wu, Qiang; Yao, Gui-Hua; Zhang, Yun
2013-01-01
Left ventricular (LV) torsion is a sensitive and global index of LV systolic and diastolic function, but how to noninvasively measure it is challenging. Two-dimensional echocardiography and the block-matching based speckle tracking method were used to measure LV torsion. Main advantages of the proposed method over the previous ones are summarized as follows: (1) The method is automatic, except for manually selecting some endocardium points on the end-diastolic frame in initialization step. (2) The diamond search strategy is applied, with a spatial smoothness constraint introduced into the sum of absolute differences matching criterion; and the reference frame during the search is determined adaptively. (3) The method is capable of removing abnormal measurement data automatically. The proposed method was validated against that using Doppler tissue imaging and some preliminary clinical experimental studies were presented to illustrate clinical values of the proposed method.
Single shot laser speckle based 3D acquisition system for medical applications
NASA Astrophysics Data System (ADS)
Khan, Danish; Shirazi, Muhammad Ayaz; Kim, Min Young
2018-06-01
The state of the art techniques used by medical practitioners to extract the three-dimensional (3D) geometry of different body parts requires a series of images/frames such as laser line profiling or structured light scanning. Movement of the patients during scanning process often leads to inaccurate measurements due to sequential image acquisition. Single shot structured techniques are robust to motion but the prevalent challenges in single shot structured light methods are the low density and algorithm complexity. In this research, a single shot 3D measurement system is presented that extracts the 3D point cloud of human skin by projecting a laser speckle pattern using a single pair of images captured by two synchronized cameras. In contrast to conventional laser speckle 3D measurement systems that realize stereo correspondence by digital correlation of projected speckle patterns, the proposed system employs KLT tracking method to locate the corresponding points. The 3D point cloud contains no outliers and sufficient quality of 3D reconstruction is achieved. The 3D shape acquisition of human body parts validates the potential application of the proposed system in the medical industry.
Strain measurement of abdominal aortic aneurysm with real-time 3D ultrasound speckle tracking.
Bihari, P; Shelke, A; Nwe, T H; Mularczyk, M; Nelson, K; Schmandra, T; Knez, P; Schmitz-Rixen, T
2013-04-01
Abdominal aortic aneurysm rupture is caused by mechanical vascular tissue failure. Although mechanical properties within the aneurysm vary, currently available ultrasound methods assess only one cross-sectional segment of the aorta. This study aims to establish real-time 3-dimensional (3D) speckle tracking ultrasound to explore local displacement and strain parameters of the whole abdominal aortic aneurysm. Validation was performed on a silicone aneurysm model, perfused in a pulsatile artificial circulatory system. Wall motion of the silicone model was measured simultaneously with a commercial real-time 3D speckle tracking ultrasound system and either with laser-scan micrometry or with video photogrammetry. After validation, 3D ultrasound data were collected from abdominal aortic aneurysms of five patients and displacement and strain parameters were analysed. Displacement parameters measured in vitro by 3D ultrasound and laser scan micrometer or video analysis were significantly correlated at pulse pressures between 40 and 80 mmHg. Strong local differences in displacement and strain were identified within the aortic aneurysms of patients. Local wall strain of the whole abdominal aortic aneurysm can be analysed in vivo with real-time 3D ultrasound speckle tracking imaging, offering the prospect of individual non-invasive rupture risk analysis of abdominal aortic aneurysms. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Ran, Hong; Zhang, Ping-Yang; Fang, Ling-Ling; Ma, Xiao-Wu; Wu, Wen-Fang; Feng, Wang-Fei
2012-07-01
To evaluate whether myocardial strain under adenosine stress calculated from two-dimensional echocardiography by automatic frame-by-frame tracking of natural acoustic markers enables objective description of myocardial viability in clinic. Two-dimensional echocardiography and two-dimensional speckle tracking imaging (2D STI) at rest were performed first and once again after adenosine was infused at 140 ug/kg/min over a period of 6 minutes in 36 stable patients with previous myocardial infarction. Then radionuclide myocardial perfusion/metabolic imaging served as the "gold standard" to define myocardial viability was given in all patients within 1 day. Two-dimensional speckle tracking images were acquired at rest and after adenosine administration. An automatic frame-by-frame tracking system of natural acoustic echocardiographic markers was used to calculate 2D strain variables including peak-systolic circumferential strain (CS(peak-sys)), radial strain (RS(peak-sys)), and longitudinal strain (LS(peak-sys)). Those segments with abnormal motion from visual assessment of two-dimensional echocardiography were selected for further study. As a result, 126 regions were viable whereas 194 were nonviable among 320 abnormal motion segments in 36 patients according to radionuclide imaging. At rest, there were no significant changes of 2D strain between the viable and nonviable myocardium. After adenosine administration (140 ug/kg/min), CS(peak-sys) had a little change of the viable myocardium while RS(peak-sys) and LS(peak-sys) increased significantly compared with those at rest. In nonviable group, CS(peak-sys), RS(peak-sys), and LS(peak-sys) had no significant changes during adenosine administration. After adenosine administration, RS(peak-sys) and LS(peak-sys) in viable group increased significantly compared with nonviable group. Obtained strain data were highly reproducible and affected in small intraobserver and interobserver variabilities. A change of radial strain more than 9.5% has a sensitivity of 83.9% and a specificity of 81.4% for viable whereas a change of longitudinal strain more than 14.6% allowed a sensitivity of 86.7% and a specificity of 90.2%. 2D STI combined with adenosine stress echocardiography could provide a new and reliable method to identify myocardium viability. © 2012, Wiley Periodicals, Inc.
How Does Subclinical Hyperthyroidism Affect Right Heart Function and Mechanics?
Tadic, Marijana; Celic, Vera; Cuspidi, Cesare; Ilic, Sanja; Zivanovic, Vladimir; Marjanovic, Tamara
2016-02-01
Right heart function and mechanics have not been investigated in patients with subclinical hyperthyroidism. Our aim was to investigate right ventricular (RV) and right atrial (RA) function and deformation as evaluated by 3-dimensional echocardiography (3DE) and speckle-tracking 2-dimensional echocardiography (2DE) in these individuals. We included 39 untreated women with endogenous subclinical hyperthyroidism and 39 healthy women matched by age. All participants underwent laboratory analyses that included thyroid hormone levels and comprehensive 2DE and 3DE examinations. Three-dimensional echocardiographic RV volumes were significantly elevated in the patients with subclinical hyperthyroidism (P < .05), whereas the 3DE RV ejection fraction was reduced in this group, but with borderline significance. Two-dimensional echocardiographic longitudinal RV and RA strain were significantly reduced in the patients with subclinical hyperthyroidism. Two-dimensional echocardiographic RV systolic and early diastolic strain rates were reduced, whereas late diastolic strain rates were increased in the patients with subclinical hyperthyroidism. The same changes were detected in RA mechanics among the patients with subclinical hyperthyroidism. The thyrotropin (TSH) level correlated with the left ventricular mass index, transmitral early diastolic peak flow velocity (E)/late diastolic flow velocity (A) ratio, tricuspid E/A ratio, 2DE RV global strain, 2DE RA, strain, and 3DE RV end-diastolic volume. A multivariate regression analysis showed that the mitral E/A ratio, 2DE RV global strain, and 3DE RV end-diastolic volume were independently associated with the TSH level. Right ventricular and RA function as evaluated by 3DE and speckle-tracking 2DE is significantly impaired in patients with subclinical hyperthyroidism. The TSH level correlated with parameters for RV function and mechanics in the whole study population. © 2016 by the American Institute of Ultrasound in Medicine.
Speckle tracking evaluation of right ventricular functions in children with sickle cell disease.
Tolba, Osama Abd Rab Elrasol; El-Shanshory, Mohamed Ramadan; El-Gamasy, Mohamed Abd Elaziz; El-Shehaby, Walid Ahmed
2017-01-01
Cardiac dysfunction is a risk factor for death in patients with sickle cell disease (SCD). Aim of the work is to evaluate the right ventricular systolic and diastolic functions by tissue Doppler and speckling tracking imaging in children with SCD. Thirty children with SCD and thirty controls were subjected to clinical, laboratory evaluations, and echocardiographic study using GE Vivid 7 (GE Medical System, Horten, Norway with a 3.5-MHz multifrequency transducer) including; Two-dimensional and tissue Doppler echocardiographic study (lateral tricuspid valve annulus peak E' velocity, lateral tricuspid valve annulus peak A' velocity, E'/A' ratio, isovolumetric relaxation time, lateral tricuspid valve annulus S' and septal S' waves and peak longitudinal systolic strain [PLSS] and time to PLSS) were done in six right ventricular segments. There was a significant decrease in right ventricular systolic and diastolic function in patients group when compared to controls. Children with SCD have impaired right ventricular systolic and diastolic functions when compared to healthy children with early evaluation of the systolic dysfunction by speckle tracking imaging technique.
Impact of transducer frequency setting on speckle tracking measures.
Olsen, Flemming Javier; Svendsen, Jesper Hastrup; Køber, Lars; Højberg, Søren; Haugan, Ketil; Jensen, Jan Skov; Biering-Sørensen, Tor
2018-03-01
Speckle tracking echocardiography is an emerging technique, which is currently being included in clinical guidelines. We sought to investigate the impact of transducer frequency settings on speckle tracking derived measures. The study comprised of 22 subjects prospectively enrolled for a randomized controlled trial (LOOP-study, Clinicaltrials.gov:NCT02036450). Patients were above 70 years of age with increased risk of stroke, and had an echocardiogram performed, which included focused images of the left ventricle. Focused images were obtained with the transducer frequency set at both 1.7/3.3 and 1.5/3.0 MHz. The images were obtained immediately after each other at the exact same position for the two settings. Speckle tracking was performed in three apical projections, allowing for acquisition of layered global longitudinal strain (GLS) and strain rate measures. Concordance between the frequency settings was tested for endo-, mid-, and epicardial GLS and strain rates by coefficients of variation, bias coefficients and visually displayed by Bland-Altman plots. Bland-Altman plots did not reveal any significant over- or underestimation of any speckle tracking measure. Bias coefficients showed that none of the measurements differed significantly between the two settings (bias for GLS endo = - 0.07 ± 2.94, p = 0.91; GLS mid = 0.02 ± 2.70, p = 0.98, GLS epi = 0.07 ± 2.53, p = 0.90). Coefficients of variation were as follows: GLS endo = 15.11%, GLS mid = 15.28%, GLS epi = 17.26%, systolic strain rate = 15.66%, early diastolic strain rate = 38.46%, late diastolic strain rate = 11%. Changing between transducer frequency settings does not systematically derange speckle tracking measures. One can safely reduce the transducer frequency without compromising the validity of speckle tracking derived measures.
Morita, T; Nakamura, K; Osuga, T; Yokoyama, N; Khoirun, N; Morishita, K; Sasaki, N; Ohta, H; Takiguchi, M
2017-08-01
To assess the repeatability and characteristics of echocardiographic indices of the right ventricular (RV) function derived from speckle-tracking echocardiography. Fourteen laboratory Beagles and 103 privately owned dogs without cardiac disease were involved in this study. Right ventricular longitudinal strain, strain rate, and a strain-related index for assessing RV dyssynchrony derived from speckle-tracking echocardiography were obtained by two different observers using five Beagles. Within-day, between-day, and interobserver coefficients of variation and the intraclass correlation coefficient of speckle-tracking echocardiography indices were determined. Both speckle-tracking echocardiography and conventional indices of RV function, including the peak velocity of systolic tricuspid annular motion, tricuspid annulus plane systolic excursion, fractional area change, and the Tei index, were obtained from 14 Beagles and 103 privately owned dogs. Relationships between echocardiographic indices and the body weight, heart rate, age, and sex were estimated by regression analysis. Speckle-tracking echocardiographic indices showed good within-day repeatability, between-day and interobserver repeatability were moderate to good. In large dogs, RV longitudinal strain, strain rate, and fractional area change were significantly decreased, while the index of RV dyssynchrony, systolic tricuspid annular motion, tricuspid annulus plane systolic excursion, and the Tei index were increased. All speckle-tracking and conventional echocardiographic indices were correlated with the body weight. The speckle-tracking echocardiography indices were highly repeatable and body weight affected speckle-tracking echocardiography indices in dogs. Further studies are needed to apply speckle-tracking echocardiography indices in dogs with cardiac disease. Copyright © 2017 Elsevier B.V. All rights reserved.
Three Dimensional Speckle Imaging Employing a Frequency-Locked Tunable Diode Laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cannon, Bret D.; Bernacki, Bruce E.; Schiffern, John T.
2015-09-01
We describe a high accuracy frequency stepping method for a tunable diode laser to improve a three dimensional (3D) imaging approach based upon interferometric speckle imaging. The approach, modeled after Takeda, exploits tuning an illumination laser in frequency as speckle interferograms of the object (specklegrams) are acquired at each frequency in a Michelson interferometer. The resulting 3D hypercube of specklegrams encode spatial information in the x-y plane of each image with laser tuning arrayed along its z-axis. We present laboratory data of before and after results showing enhanced 3D imaging resulting from precise laser frequency control.
Additive Prognostic Value of Left Ventricular Systolic Dysfunction in a Population-Based Cohort.
Kuznetsova, Tatiana; Cauwenberghs, Nicholas; Knez, Judita; Yang, Wen-Yi; Herbots, Lieven; D'hooge, Jan; Haddad, Francois; Thijs, Lutgarde; Voigt, Jens-Uwe; Staessen, Jan A
2016-07-01
Techniques of 2-dimensional speckle tracking enable the measurement of myocardial deformation (strain) during systole. Recent clinical studies explored the prognostic role of left ventricular global longitudinal strain (GLS). However, there are few data on the association between cardiovascular outcome and GLS in the community. Therefore, we hypothesized that GLS contains additive prognostic information over and beyond traditional cardiovascular risk factors in a large, population-based cohort. We measured GLS by 2-dimensional speckle tracking in the apical 4-chamber view in 791 participants (mean age 50.9 years). We calculated multivariable adjusted hazard ratios for midwall, endocardial, and epicardial GLS, while accounting for family cluster and cardiovascular risk factors. Median follow-up was 7.9 years (5th to 95th percentile, 3.7-9.6). In continuous analysis, with adjustments applied for covariables, midwall, endocardial, and epicardial GLS were significant predictors of fatal and nonfatal cardiovascular (n=96; P<0.0001) and cardiac events (n=68; P≤0.001). In the sex-specific low quartile of midwall GLS (<18.8% in women and <17.4% in men), the risk was significantly higher than the average population risk for cardiovascular (128%, P<0.0001) and cardiac (94%, P=0.0007) events. We also noticed that the risk for cardiovascular events increased with increasing number of left ventricular abnormalities, such as low GLS, diastolic dysfunction, and hypertrophy (log-rank P<0.0001). Low GLS measured by 2-dimensional speckle tracking predicts future cardiovascular events independent of conventional risk factors. Left ventricular midwall strain represents a simple echocardiographic measure, which might be used for assessing cardiovascular risk in a population-based cohort. © 2016 American Heart Association, Inc.
Kumar, Alok; Puri, Goverdhan Dutt; Bahl, Ajay
2017-10-01
Speckle tracking, when combined with 3-dimensional (3D) left ventricular ejection fraction, might prove to be a more sensitive marker for postoperative ventricular dysfunction. This study investigated early outcomes in a cohort of patients with left ventricular dysfunction undergoing cardiac surgery. Prospective, blinded, observational study. University hospital; single institution. The study comprised 73 adult patients with left ventricular ejection fraction <50% undergoing cardiac surgery using cardiopulmonary bypass. Routine transesophageal echocardiography before and after bypass. Global longitudinal strain using speckle tracking and 3D left ventricular ejection fraction were computed using transesophageal echocardiography. Mean prebypass global longitudinal strain and 3D left ventricle ejection fraction were significantly lower in patients with postoperative low-cardiac-output syndrome compared with patients who did not develop low cardiac output (global longitudinal strain -7.5% v -10.7% and 3D left ventricular ejection fraction 29% v 39%, respectively; p < 0.0001). The cut-off value of global longitudinal strain predicting postoperative low-cardiac-output syndrome was -6%, with 95% sensitivity and 68% specificity; and 3D left ventricular ejection fraction was 19% with 98% sensitivity and 81% specificity. Preoperative left ventricular global longitudinal strain (-6%) and 3D left ventricular ejection fraction (19%) together could act as predictor of postoperative low-cardiac-output states with high sensitivity (99.9%) in patients undergoing cardiac surgery. Copyright © 2017 Elsevier Inc. All rights reserved.
Speckle-based three-dimensional velocity measurement using spatial filtering velocimetry.
Iversen, Theis F Q; Jakobsen, Michael L; Hanson, Steen G
2011-04-10
We present an optical method for measuring the real-time three-dimensional (3D) translational velocity of a diffusely scattering rigid object observed through an imaging system. The method is based on a combination of the motion of random speckle patterns and regular fringe patterns. The speckle pattern is formed in the observation plane of the imaging system due to reflection from an area of the object illuminated by a coherent light source. The speckle pattern translates in response to in-plane translation of the object, and the presence of an angular offset reference wave coinciding with the speckle pattern in the observation plane gives rise to interference, resulting in a fringe pattern that translates in response to the out-of-plane translation of the object. Numerical calculations are performed to evaluate the dynamic properties of the intensity distribution and the response of realistic spatial filters designed to measure the three components of the object's translational velocity. Furthermore, experimental data are presented that demonstrate full 3D velocity measurement. © 2011 Optical Society of America
Badano, Luigi P; Kolias, Theodore J; Muraru, Denisa; Abraham, Theodore P; Aurigemma, Gerard; Edvardsen, Thor; D'Hooge, Jan; Donal, Erwan; Fraser, Alan G; Marwick, Thomas; Mertens, Luc; Popescu, Bogdan A; Sengupta, Partho P; Lancellotti, Patrizio; Thomas, James D; Voigt, Jens-Uwe
2018-03-27
The EACVI/ASE/Industry Task Force to standardize deformation imaging prepared this consensus document to standardize definitions and techniques for using two-dimensional (2D) speckle tracking echocardiography (STE) to assess left atrial, right ventricular, and right atrial myocardial deformation. This document is intended for both the technical engineering community and the clinical community at large to provide guidance on selecting the functional parameters to measure and how to measure them using 2D STE.This document aims to represent a significant step forward in the collaboration between the scientific societies and the industry since technical specifications of the software packages designed to post-process echocardiographic datasets have been agreed and shared before their actual development. Hopefully, this will lead to more clinically oriented software packages which will be better tailored to clinical needs and will allow industry to save time and resources in their development.
Digital Holographic Interferometry and Speckle Correlation
NASA Astrophysics Data System (ADS)
Yamaguchi, Ichirou
2010-04-01
Relations and combinations between holographic interferometry and speckle correlation in contouring by phase-shifting digital holography are discussed. Three-dimensional distributions of correlations of the complex amplitudes and intensities before and after the laser wavelength shift are calculated in numerical simulations where a rough surface is modeled with random numbers. Fringe localization related to speckle displacement as well as speckle suppression in phase analysis are demonstrated for general surface shape and recording conditions.
Weng, Ken-Pen; Hung, Yu-Chi; Huang, Shih-Hui; Wu, Huang-Wei; Chien, Kuang-Jen; Lin, Chu-Chuan; Peng, Hsu-Hsia; Wu, Ming-Ting
2018-02-01
The aim of this prospective study was to assess biventricular performance in asymptomatic adolescents with repaired tetralogy of Fallot (TOF) using 2D speckle tracking and real time 3D echocardiography simultaneously. We studied 31 patients with repaired TOF (M/F: 22/9, age: 16.1 ± 6.1 yrs) who had history of cardiac surgery with mean follow-up duration of 12.8 years, and 32 age- and sex-matched normal individuals (M/F: 23/9, age: 16.6 ± 5.1 yrs). All subjects underwent speckle tracking and 3D echocardiography, electrocardiogram, treadmill, and blood sampling for measurement of brain natriuretic peptide (BNP). Compared to the control group, the TOF group had higher BNP level (31.8 ± 21.4 vs 14.1 ± 12.4 pg/ml, p < 0.01), lower peak oxygen consumption (8.4 ± 1.7 vs 9.9 ± 1.6 ml/kg/min, p < 0.05), and longer QRS duration (126 ± 30 vs 82 ± 9 ms, p < 0.01). Patients with repaired TOF had significantly impaired right ventricle (RV) global and all six regional longitudinal strain and strain rate than normal controls. Left ventricle (LV) global and mainly apical regional longitudinal strain and strain rate were reduced in patients with repaired TOF. There was a significant correlation of global longitudinal strain (r = 0.456, p = 0.01) and global time to peak longitudinal strain (r = 0.484, p < 0.01) between LV and RV in patients with repaired TOF. In terms of 3D echo cardiographic volume data, patients with repaired TOF had lower LV stroke volume index (p < 0.05), but higher RV end diastolic volume index (p < 0.01), RV end systolic volume index (p < 0.01), RV stroke volume index (p < 0.01), and pulmonary regurgitation fraction (p < 0.01) than normal controls. Our results suggest asymptomatic adolescents with repaired TOF had abnormal biventricular myocardial performance, as demonstrated by combined 2D speckle-tracking and 3D echocardiography. The implications of these findings for management of adolescents late after repaired TOF remain to be determined. Copyright © 2017. Published by Elsevier Taiwan LLC.
Wu, Jun; Yu, Zhijing; Wang, Tao; Zhuge, Jingchang; Ji, Yue; Xue, Bin
2017-06-01
Airplane wing deformation is an important element of aerodynamic characteristics, structure design, and fatigue analysis for aircraft manufacturing, as well as a main test content of certification regarding flutter for airplanes. This paper presents a novel real-time detection method for wing deformation and flight flutter detection by using three-dimensional speckle image correlation technology. Speckle patterns whose positions are determined through the vibration characteristic of the aircraft are coated on the wing; then the speckle patterns are imaged by CCD cameras which are mounted inside the aircraft cabin. In order to reduce the computation, a matching technique based on Geodetic Systems Incorporated coded points combined with the classical epipolar constraint is proposed, and a displacement vector map for the aircraft wing can be obtained through comparing the coordinates of speckle points before and after deformation. Finally, verification experiments containing static and dynamic tests by using an aircraft wing model demonstrate the accuracy and effectiveness of the proposed method.
Nishizaki, Tatsuya; Matoba, Osamu; Nitta, Kouichi
2014-09-01
The recording properties of three-dimensional speckle-shift multiplexing in reflection-type holographic memory are analyzed numerically. Three-dimensional recording can increase the number of multiplexed holograms by suppressing the cross-talk noise from adjacent holograms by using depth-direction multiplexing rather than in-plane multiplexing. Numerical results indicate that the number of multiplexed holograms in three-layer recording can be increased by 1.44 times as large as that of a single-layer recording when an acceptable signal-to-noise ratio is set to be 2 when NA=0.43 and the thickness of the recording medium is 0.5 mm.
Koene, S; Timmermans, J; Weijers, G; de Laat, P; de Korte, C L; Smeitink, J A M; Janssen, M C H; Kapusta, L
2017-03-01
Cardiomyopathy is a common complication of mitochondrial disorders, associated with increased mortality. Two dimensional speckle tracking echocardiography (2DSTE) can be used to quantify myocardial deformation. Here, we aimed to determine the usefulness of 2DSTE in detecting and monitoring subtle changes in myocardial dysfunction in carriers of the 3243A>G mutation in mitochondrial DNA. In this retrospective pilot study, 30 symptomatic and asymptomatic carriers of the mitochondrial 3243A>G mutation of whom two subsequent echocardiograms were available were included. We measured longitudinal, circumferential and radial strain using 2DSTE. Results were compared to published reference values. Speckle tracking was feasible in 90 % of the patients for longitudinal strain. Circumferential and radial strain showed low face validity (low number of images with sufficient quality; suboptimal tracking) and were therefore rejected for further analysis. Global longitudinal strain showed good face validity, and was abnormal in 56-70 % (depending on reference values used) of the carriers (n = 27). Reproducibility was good (mean difference of 0.83 for inter- and 0.40 for intra-rater reproducibility; ICC 0.78 and 0.89, respectively). The difference between the first and the second measurement exceeded the measurement variance in 39 % of the cases (n = 23; feasibility of follow-up 77 %). Even in data collected as part of clinical care, two-dimensional strain echocardiography seems a feasible method to detect and monitor subtle changes in longitudinal myocardial deformation in adult carriers of the mitochondrial 3243A>G mutation. Based on our data and the reported accuracy of global longitudinal strain in other studies, we suggest the use of global longitudinal strain in a prospective follow-up or intervention study.
Scandura, Salvatore; Dipasqua, Fabio; Gargiulo, Giuseppe; Capodanno, Davide; Caggegi, Anna; Grasso, Carmelo; Mangiafico, Sarah; Pistritto, Anna Maria; Immè, Sebastiano; Chiarandà, Marta; Ministeri, Margherita; Ronsivalle, Giuseppe; Cannata, Stefano; Arcidiacono, Antonio Andrea; Capranzano, Piera; Tamburino, Corrado
2016-11-01
To appraise the early effect of percutaneous mitral valve repair with the MitraClip system on myocardial function using real-time three-dimensional speckle-tracking echocardiography (3D-STE). Consecutive patients with moderate-to-severe or severe mitral regurgitation, undergoing mitral valve repair with the MitraClip system, were prospectively evaluated during the peri-procedural workout and follow-up. Left ventricular deformation was evaluated by a two-dimensional and 3D speckle-tracking analysis. 3D-STE acquisitions were elaborated obtaining real-time 3D global longitudinal strain evaluation, and by appraising both volumetric and hemodynamic parameters (i.e. left ventricular end-diastolic volume, left ventricular end-systolic volume, left ventricular ejection fraction, cardiac output, and stroke volume). In all, 30 patients were included. At 1-month follow-up, 3D-STE analysis revealed no changes in left ventricular end-diastolic volume (162.6 ± 73.7 ml at baseline vs. 159.8 ± 64.5 ml at 1-month follow-up; P = 0.63) and a downward trend in left ventricular end-systolic volume (104.7 ± 52.0 vs. 100.1 ± 50.4 ml, respectively; P = 0.06). Left ventricular ejection fraction did not significantly increase (38.1 ± 11.3% at baseline vs. 39.4 ± 11.0% at 1-month follow-up; P = 0.20). No significant changes were reported in cardiac output (4.3 ± 2.0 l/min at baseline vs. 4.0 ± 1.5 l/min at follow-up; P = 0.377) and in stroke volume (59.5 ± 25.5 ml at baseline vs. 59.9 ± 20.7 ml at follow-up; P = 0.867). On the contrary, left ventricular deformation capability significantly improved, with the real-time 3D global longitudinal strain value changing from -9.8 ± 4.1% at baseline to -11.0 ± 4.4% at follow-up (P = 0.018). Accurately assessing myocardial function by the use of 3D-STE, this study reported irrelevant early changes in left ventricular size, but a positive effect on left ventricular deformation capability following mitral valve repair with the MitraClip system. These preliminary results need to be confirmed in larger series and extended to long-term follow-up.
Fröberg, Åsa; Mårtensson, Mattias; Larsson, Matilda; Janerot-Sjöberg, Birgitta; D'Hooge, Jan; Arndt, Anton
2016-10-01
Ultrasound speckle tracking offers a non-invasive way of studying strain in the free Achilles tendon where no anatomical landmarks are available for tracking. This provides new possibilities for studying injury mechanisms during sport activity and the effects of shoes, orthotic devices, and rehabilitation protocols on tendon biomechanics. To investigate the feasibility of using a commercial ultrasound speckle tracking algorithm for assessing strain in tendon tissue. A polyvinyl alcohol (PVA) phantom, three porcine tendons, and a human Achilles tendon were mounted in a materials testing machine and loaded to 4% peak strain. Ultrasound long-axis cine-loops of the samples were recorded. Speckle tracking analysis of axial strain was performed using a commercial speckle tracking software. Estimated strain was then compared to reference strain known from the materials testing machine. Two frame rates and two region of interest (ROI) sizes were evaluated. Best agreement between estimated strain and reference strain was found in the PVA phantom (absolute error in peak strain: 0.21 ± 0.08%). The absolute error in peak strain varied between 0.72 ± 0.65% and 10.64 ± 3.40% in the different tendon samples. Strain determined with a frame rate of 39.4 Hz had lower errors than 78.6 Hz as was the case with a 22 mm compared to an 11 mm ROI. Errors in peak strain estimation showed high variability between tendon samples and were large in relation to strain levels previously described in the Achilles tendon. © The Foundation Acta Radiologica 2016.
Zaitsev, Vladimir Y; Matveyev, Alexandr L; Matveev, Lev A; Gelikonov, Grigory V; Gelikonov, Valentin M; Vitkin, Alex
2015-07-01
Feasibility of speckle tracking in optical coherence tomography (OCT) based on digital image correlation (DIC) is discussed in the context of elastography problems. Specifics of applying DIC methods to OCT, compared to processing of photographic images in mechanical engineering applications, are emphasized and main complications are pointed out. Analytical arguments are augmented by accurate numerical simulations of OCT speckle patterns. In contrast to DIC processing for displacement and strain estimation in photographic images, the accuracy of correlational speckle tracking in deformed OCT images is strongly affected by the coherent nature of speckles, for which strain-induced complications of speckle “blinking” and “boiling” are typical. The tracking accuracy is further compromised by the usually more pronounced pixelated structure of OCT scans compared with digital photographic images in classical DIC applications. Processing of complex-valued OCT data (comprising both amplitude and phase) compared to intensity-only scans mitigates these deleterious effects to some degree. Criteria of the attainable speckle tracking accuracy and its dependence on the key OCT system parameters are established.
Markin, Nicholas W; Chamsi-Pasha, Mohammed; Luo, Jiangtao; Thomas, Walker R; Brakke, Tara R; Porter, Thomas R; Shillcutt, Sasha K
2017-02-01
Perioperative evaluation of right ventricular (RV) systolic function is important to follow intraoperative changes, but it is often not possible to assess with transthoracic echocardiographic (TTE) imaging, because of surgical field constraints. Echocardiographic RV quantification is most commonly performed using tricuspid annular plane systolic excursion (TAPSE), but it is not clear whether this method works with transesophageal echocardiographic (TEE) imaging. This study was performed to evaluate the relationship between TTE and TEE TAPSE distances measured with M-mode imaging and in comparison with speckle-tracking TTE and TEE measurements. Prospective observational TTE and TEE imaging was performed during elective cardiac surgical procedures in 100 subjects. Speckle-tracking echocardiographic TAPSE distances were determined and compared with the TTE M-mode TAPSE standard. Both an experienced and an inexperienced user of the speckle-tracking echocardiographic software evaluated the images, to enable interobserver assessment in 84 subjects. The comparison between TTE M-mode TAPSE and TEE M-mode TAPSE demonstrated significant variability, with a Spearman correlation of 0.5 and a mean variance in measurement of 6.5 mm. There was equivalence within data pairs and correlations between TTE M-mode TAPSE and both speckle-tracking TTE and speckle-tracking TEE TAPSE, with Spearman correlations of 0.65 and 0.65, respectively. The average variance in measurement was 0.6 mm for speckle-tracking TTE TAPSE and 1.5 mm for speckle-tracking TEE TAPSE. Using TTE M-mode TAPSE as a control, TEE M-mode TAPSE results are not accurate and should not be used clinically to evaluate RV systolic function. The relationship between speckle-tracking echocardiographic TAPSE and TTE M-mode TAPSE suggests that in the perioperative setting, speckle-tracking TEE TAPSE might be used to quantitatively evaluate RV systolic function in the absence of TTE imaging. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Gao, Xinya; Wang, Yonghong; Li, Junrui; Dan, Xizuo; Wu, Sijin; Yang, Lianxiang
2017-06-01
It is difficult to measure absolute three-dimensional deformation using traditional digital speckle pattern interferometry (DSPI) when the boundary condition of an object being tested is not exactly given. In practical applications, the boundary condition cannot always be specifically provided, limiting the use of DSPI in real-world applications. To tackle this problem, a DSPI system that is integrated by the spatial carrier method and a color camera has been established. Four phase maps are obtained simultaneously by spatial carrier color-digital speckle pattern interferometry using four speckle interferometers with different illumination directions. One out-of-plane and two in-plane absolute deformations can be acquired simultaneously without knowing the boundary conditions using the absolute deformation extraction algorithm based on four phase maps. Finally, the system is proved by experimental results through measurement of the deformation of a flat aluminum plate with a groove.
Optical vortices as potential indicators of biophysical dynamics
NASA Astrophysics Data System (ADS)
Majumdar, Anindya; Kirkpatrick, Sean J.
2017-03-01
Laser speckle patterns are granular patterns produced as a result of random interference of light waves. Optical vortices (OVs) are phase singularities in such speckle fields, characterized by zero intensity and an undefined phase. Decorrelation of the speckle fields causes these OVs to move in both time and space. In this work, a variety of parameters of these OVs have been studied. The speckle fields were simulated to undergo three distinct decorrelation behaviors- Gaussian, Lorentzian and constant decorrelations. Different decorrelation behaviors represent different dynamics. For example, Lorentzian and Gaussian decorrelations represent Brownian and ordered motions, respectively. Typical dynamical systems in biophysics are generally argued to be a combination of these. For each of the decorrelation behaviors under study, the vortex trails were tracked while varying the rate of decorrelation. Parameters such as the decorrelation length, average trail length and the deviation of the vortices as they traversed in the speckle field, were studied. Empirical studies were also performed to define the distinction between trails arising from different speckle decorrelation behaviors. The initial studies under stationary speckle fields were followed up by similar studies on shifting fields. A new idea to employ Poincaŕe plots in speckle analysis has also been introduced. Our studies indicate that tracking OVs can be a potential method to study cell and tissue dynamics.
O'Connor, Daniel M; Smith, Robert S; Piras, Bryan A; Beyers, Ronald J; Lin, Dan; Hossack, John A; French, Brent A
2016-04-22
Ivabradine selectively inhibits the pacemaker current of the sinoatrial node, slowing heart rate. Few studies have examined the effects of ivabradine on the mechanical properties of the heart after reperfused myocardial infarction (MI). Advances in ultrasound speckle-tracking allow strain analyses to be performed in small-animal models, enabling the assessment of regional mechanical function. After 1 hour of coronary occlusion followed by reperfusion, mice received 10 mg/kg per day of ivabradine dissolved in drinking water (n=10), or were treated as infarcted controls (n=9). Three-dimensional high-frequency echocardiography was performed at baseline and at days 2, 7, 14, and 28 post-MI. Speckle-tracking software was used to calculate intramural longitudinal myocardial strain (Ell) and strain rate. Standard deviation time to peak radial strain (SD Tpeak Err) and temporal uniformity of strain were calculated from short-axis cines acquired in the left ventricular remote zone. Ivabradine reduced heart rate by 8% to 16% over the course of 28 days compared to controls (P<0.001). On day 28 post-MI, the ivabradine group was found to have significantly smaller end-systolic volumes, greater ejection fraction, reduced wall thinning, and greater peak Ell and Ell rate in the remote zone, as well as globally. Temporal uniformity of strain and SD Tpeak Err were significantly smaller in the ivabradine-treated group by day 28 (P<0.05). High-frequency ultrasound speckle-tracking demonstrated decreased left ventricular remodeling and dyssynchrony, as well as improved mechanical performance in remote myocardium after heart rate reduction with ivabradine. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Nagle, Anna S.; Nageswaren, Ashok R.; Haridas, Balakrishna; Mast, T. D.
2014-01-01
Little is understood about the biomechanical changes leading to pelvic floor disorders such as stress urinary incontinence. In order to measure regional biomechanical properties of the pelvic floor muscles in vivo, a three dimensional (3D) strain tracking technique employing correlation of volumetric ultrasound images has been implemented. In this technique, local 3D displacements are determined as a function of applied stress and then converted to strain maps. To validate this approach, an in vitro model of the pubovisceral muscle, with a hemispherical indenter emulating the downward stress caused by intra-abdominal pressure, was constructed. Volumetric B-scan images were recorded as a function of indenter displacement while muscle strain was measured independently by a sonomicrometry system (Sonometrics). Local strains were computed by ultrasound image correlation and compared with sonomicrometry-measured strains to assess strain tracking accuracy. Image correlation by maximizing an exponential likelihood function was found more reliable than the Pearson correlation coefficient. Strain accuracy was dependent on sizes of the subvolumes used for image correlation, relative to characteristic speckle length scales of the images. Decorrelation of echo signals was mapped as a function of indenter displacement and local tissue orientation. Strain measurement accuracy was weakly related to local echo decorrelation. PMID:24900165
Li, Shu-Juan; Hwang, Yu-Yan; Ha, Shau-Yin; Chan, Godfrey C F; Mok, Amanda S P; Wong, Sophia J; Cheung, Yiu-Fai
2016-09-01
The new three-dimensional speckle tracking echocardiography (3DSTE) may enable comprehensive quantification of global left ventricular (LV) myocardial mechanics. Twenty-four patients aged 29.3 ± 5.2 years and 22 controls were studied. 3DSTE was performed to assess LV 3D global strain, twist and torsion, ejection fraction, and systolic dyssynchrony index (SDI). The LV SDI was calculated as % of SD of times-to-peak strain of 16 segments/RR interval. The global performance index (GPI) was calculated as (global 3D strain·torsion)/SDI. Area under the receiver operating characteristic curve (AUC) was calculated to determine the capability of 3DSTE parameters to discriminate between patients with (cardiac magnetic resonance T2* <20 ms) and those without myocardial iron overload. Compared with controls, patients had significantly lower LV global 3D strain (P < 0.001), twist (P = 0.01), torsion (P = 0.04), and ejection fraction (P < 0.001) and greater SDI (P < 0.001). The GPI was lower in patients than controls (P < 0.001). T2* value correlated positively with global 3D strain (r = 0.74, P < 0.001) and GPI (r = 0.63, P = 0.001), and negatively with SDI (r = -0.44, P = 0.03). The AUCs of GPI, global 3D strain, ejection fraction, torsion, and 1/SDI were 0.94, 0.90, 0.87, 0.82, and 0.70, respectively. The GPI cutoff of 2.7°/cm had a sensitivity of 94.9% and a specificity of 88.9% of differentiating patients with from those without myocardial iron overload. The LV composite index of strain, torsion, and dyssynchrony derived from 3DSTE enables sensitive detection of myocardial iron overload in patients with thalassemia. © 2016, Wiley Periodicals, Inc.
Measurement of impinging butane flame using combined optical system with digital speckle tomography
NASA Astrophysics Data System (ADS)
Ko, Han Seo; Ahn, Seong Soo; Kim, Hyun Jung
2011-11-01
Three-dimensional density distributions of an impinging and eccentric flame were measured experimentally using a combined optical system with digital speckle tomography. In addition, a three-dimensional temperature distribution of the flame was reconstructed from an ideal gas equation based on the reconstructed density data. The flame was formed by the ignition of premixed butane/air from air holes and impinged upward against a plate located 24 mm distance from the burner nozzle. In order to verify the reconstruction process for the experimental measurements, numerically synthesized phantoms of impinging and eccentric flames were derived and reconstructed using a developed three-dimensional multiplicative algebraic reconstruction technique (MART). A new scanning technique was developed for the accurate analysis of speckle displacements necessary for investigating the wall jet regions of the impinging flame at which a sharp variation of the flow direction and pressure gradient occur. The reconstructed temperatures by the digital speckle tomography were applied to the boundary condition for numerical analysis of a flame impinged plate. Then, the numerically calculated temperature distribution of the upper side of the flame impinged plate was compared to temperature data taken by an infrared camera. The absolute average uncertainty between the numerical and infrared camera data was 3.7%.
Cho, Eun Jeong; Park, Sung-Ji; Kim, Eun Kyoung; Lee, Ga Yeon; Chang, Sung-A; Choi, Jin-Oh; Lee, Sang-Chol; Park, Seung Woo
2017-04-01
The aim of this study was to determine the capability of real time three-dimensional echocardiography (RT3DE) and two-dimensional (2D) multilayer speckle tracking echocardiography (MSTE) for evaluation of early myocardial dysfunction triggered by increased left ventricular (LV) wall thickness in severe aortic stenosis (AS) with normal LV ejection fraction (EF≥55%). Conventional, RT3D STE and 2D MSTE were performed in 45 patients (mean 68.9±9.0 years) with severe AS (aortic valve area <1 cm 2 , aortic velocity Vmax >4 m/s or mean PG >40 mm Hg) and normal left ventricular ejection fraction (LVEF) without overt coronary artery disease and in 18 age-, sex-matched healthy controls. Global longitudinal strain (GLS), global circumferential strain (GCS), global area strain (GAS), and global radial strain (GRS) were calculated using RT3DE and MSTE. The severe AS group had lower 3D GLS, GRS, GAS and 2D epicardium, and mid-wall and endocardium GLS compared to healthy controls. In MSTE analysis, 2D LS and CS values decreased from the endocardial layer toward the epicardial layer. Severe AS patients with increased LV wall thickness had lower 3D GLS and 2D epicardium, and mid-wall and endocardium GLS compared with severe AS patients without LV wall thickening. GLS on RT3D STE was correlated with GLS on 2D MSTE, left ventricular mass index, LVEF, left atrial volume index, and lnNT-proBNP. RT3DE and 2D MSTE can be used to identify subtle contractile dysfunction triggered by increased LV wall thickness in severe AS with normal LVEF. Therefore, RT3D STE and 2D MSTE may provide additional information that can facilitate decision-making regarding severe AS patients with increased LV wall thickness and normal LV function. © 2017, Wiley Periodicals, Inc.
Negoita, Madalina; Zolgharni, Massoud; Dadkho, Elham; Pernigo, Matteo; Mielewczik, Michael; Cole, Graham D; Dhutia, Niti M; Francis, Darrel P
2016-09-01
To determine the optimal frame rate at which reliable heart walls velocities can be assessed by speckle tracking. Assessing left ventricular function with speckle tracking is useful in patient diagnosis but requires a temporal resolution that can follow myocardial motion. In this study we investigated the effect of different frame rates on the accuracy of speckle tracking results, highlighting the temporal resolution where reliable results can be obtained. 27 patients were scanned at two different frame rates at their resting heart rate. From all acquired loops, lower temporal resolution image sequences were generated by dropping frames, decreasing the frame rate by up to 10-fold. Tissue velocities were estimated by automated speckle tracking. Above 40 frames/s the peak velocity was reliably measured. When frame rate was lower, the inter-frame interval containing the instant of highest velocity also contained lower velocities, and therefore the average velocity in that interval was an underestimate of the clinically desired instantaneous maximum velocity. The higher the frame rate, the more accurately maximum velocities are identified by speckle tracking, until the frame rate drops below 40 frames/s, beyond which there is little increase in peak velocity. We provide in an online supplement the vendor-independent software we used for automatic speckle-tracked velocity assessment to help others working in this field. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Muraru, Denisa; Onciul, Sebastian; Peluso, Diletta; Soriani, Nicola; Cucchini, Umberto; Aruta, Patrizia; Romeo, Gabriella; Cavalli, Giacomo; Iliceto, Sabino; Badano, Luigi P
2016-02-01
Despite the fact that assessment of right ventricular longitudinal strain (RVLS) carries important implications for patient diagnosis, prognosis, and treatment, its implementation in clinical settings has been hampered by the limited reference values and the lack of uniformity in software, method, and definition used for measuring RVLS. Accordingly, this study was designed to establish (1) the reference values for RVLS by 2-dimensional speckle-tracking echocardiography; and (2) their relationship with demographic, hemodynamic, and cardiac factors. In 276 healthy volunteers (55% women; age, 18-76 years), free wall and septum RVLS (6 segments) and free wall RVLS (3 segments) using both 6- and 3-segment regions of interest were obtained. Feasibility of 6-segment RVLS was 92%. Free wall RVLS from 3- versus 6-segment regions of interest had similar values, yet 6-segment region of interest was more feasible (86% versus 73%; P<0.001) and reproducible. Reference values (lower limits of normality) were as follows: 6-segment RVLS, -24.7±2.6% (-20.0%) for men and -26.7±3.1% (-20.3%) for women; 3-segment RVLS, -29.3±3.4% (-22.5%) for men and -31.6±4.0% (-23.3%) for women (P<0.001). Free wall RVLS was 5±2 strain units (%) larger in magnitude than 6-segment RVLS, 10±4% larger than septal RVLS, and 2±4% larger in women than in men (P<0.001). At multivariable analysis, age, sex, pulmonary systolic pressure, right atrial minimal volume, as well as right atrial and left ventricular longitudinal strain resulted as correlates of RVLS values. This is the largest study providing sex- and method-specific reference values for RVLS. Our data may foster the implementation of 2-dimensional speckle-tracking echocardiography-derived RV analysis in clinical practice. © 2016 American Heart Association, Inc.
Li, Jing-Jie; Wei, Fang; Chen, Ju-Gang; Yu, Yan-Wei; Gu, Hong-Yue; Jiang, Rui; Wu, Xiu-Li; Sun, Qian
2014-01-01
Purpose The aim was to assess atrial fibrillation (AF) and vulnerability in Wolff-Parkinson-White (WPW) syndrome patients using two-dimensional speckle tracking echocardiography (2D-STE). Methods All patients were examined via transthoracic echocardiography and 2D-STE in order to assess atrial function 7 days before and 10 days after RF catheter ablation. A postoperative 3-month follow-up was performed via outpatient visit or telephone calls. Results Results showed significant differences in both body mass index (BMI) and supraventricular tachycardia (SVT) duration between WPW patients and DAVNP patients (both P<0.05). Echocardiography revealed that the maximum left atrial volume (LAVmax) and the left ventricular mass index (LVMI) in diastole increased noticeably in patients with WPW compared to patients with DAVNP both before and after ablation (all P<0.05). Before ablation, there were obvious differences in the levels of SRs, SRe, and SRa from the 4-chamber view (LA) in the WPW patients group compared with patients in the DAVNP group (all P<0.05). In the AF group, there were significant differences in the levels of systolic strain rate (SRs), early diastolic strain rate (SRe), and late diastolic strain rate (SRa) from the 4-chamber view (LA) both before and after ablation (all P<0.05). In the non-AF group, there were decreased SRe levels from the 4-chamber view (LA/RA) pre-ablation compared to post-ablation (all P<0.05). Conclusion Our findings provide convincing evidence that WPW syndrome may result in increased atrial vulnerability and contribute to the development of AF. Further, RF catheter ablation of AAV pathway can potentially improve atrial function in WPW syndrome patients. Two-dimensional speckle tracking echocardiography imaging in WPW patients would be necessary in the evaluation and improvement of the overall function of RF catheter ablation in a long-term follow-up period. PMID:25397668
Li, Jing-Jie; Wei, Fang; Chen, Ju-Gang; Yu, Yan-Wei; Gu, Hong-Yue; Jiang, Rui; Wu, Xiu-Li; Sun, Qian
2014-01-01
The aim was to assess atrial fibrillation (AF) and vulnerability in Wolff-Parkinson-White (WPW) syndrome patients using two-dimensional speckle tracking echocardiography (2D-STE). All patients were examined via transthoracic echocardiography and 2D-STE in order to assess atrial function 7 days before and 10 days after RF catheter ablation. A postoperative 3-month follow-up was performed via outpatient visit or telephone calls. Results showed significant differences in both body mass index (BMI) and supraventricular tachycardia (SVT) duration between WPW patients and DAVNP patients (both P<0.05). Echocardiography revealed that the maximum left atrial volume (LAVmax) and the left ventricular mass index (LVMI) in diastole increased noticeably in patients with WPW compared to patients with DAVNP both before and after ablation (all P<0.05). Before ablation, there were obvious differences in the levels of SRs, SRe, and SRa from the 4-chamber view (LA) in the WPW patients group compared with patients in the DAVNP group (all P<0.05). In the AF group, there were significant differences in the levels of systolic strain rate (SRs), early diastolic strain rate (SRe), and late diastolic strain rate (SRa) from the 4-chamber view (LA) both before and after ablation (all P<0.05). In the non-AF group, there were decreased SRe levels from the 4-chamber view (LA/RA) pre-ablation compared to post-ablation (all P<0.05). Our findings provide convincing evidence that WPW syndrome may result in increased atrial vulnerability and contribute to the development of AF. Further, RF catheter ablation of AAV pathway can potentially improve atrial function in WPW syndrome patients. Two-dimensional speckle tracking echocardiography imaging in WPW patients would be necessary in the evaluation and improvement of the overall function of RF catheter ablation in a long-term follow-up period.
SIR-B ocean-wave enhancement with fast Fourier transform techniques
NASA Technical Reports Server (NTRS)
Tilley, David G.
1987-01-01
Shuttle Imaging Radar (SIR-B) imagery is Fourier filtered to remove the estimated system-transfer function, reduce speckle noise, and produce ocean scenes with a gray scale that is proportional to wave height. The SIR-B system response to speckled scenes of uniform surfaces yields an estimate of the stationary wavenumber response of the imaging radar, modeled by the 15 even terms of an eighth-order two-dimensional polynomial. Speckle can also be used to estimate the dynamic wavenumber response of the system due to surface motion during the aperture synthesis period, modeled with a single adaptive parameter describing an exponential correlation along track. A Fourier filter can then be devised to correct for the wavenumber response of the remote sensor and scene correlation, with subsequent subtraction of an estimate of the speckle noise component. A linearized velocity bunching model, combined with a surface tilt and hydrodynamic model, is incorporated in the Fourier filter to derive estimates of wave height from the radar intensities corresponding to individual picture elements.
Awadalla, Hany; Saleh, Mohamed Ayman; Abdel Kader, Mohamed; Mansour, Amr
2017-08-01
Left ventricular (LV) torsion is a novel method to assess systolic LV function. This study aimed at exploring the utility of 2D speckle tracking-based assessment of left ventricular torsion in patients with acute myocardial infarction (AMI) undertaking primary percutaneous intervention (pPCI) in predicting left ventricular remodeling. The study included 115 patients (mean±SD, age 52.2±9.67, males 84.3%) who underwent pPCI for AMI. Echocardiographic assessment of LV torsion by two-dimensional speckle tracking was performed early after the index pPCI. Patients underwent repeat echocardiography at 6 months to detect remodeling. LV torsion in the acute setting was significantly lower in those who demonstrated LV remodeling at follow-up compared to those without remodeling (7.56±1.95 vs 15.16±4.65; P<.005). Multivariate analysis identified peak CK & CK-MB elevation (β=-0.767 and -0.725; P<.001), SWMA index (β=-0.843; P<.001), and Simpson's derived LV ejection fraction (LVEF; β=0.802; P<.001) as independent predictors of baseline LV torsion. It also identified peak LV torsion (β: 0.27; 95% CI: 0.15-0.5, P=.001) and SWMA index (β: 1.07, 95% CI: 1.03-1.12, P=.005) as independent predictors of LV remodeling. Baseline Killip's grades II and higher (β: 48.6; 95% CI 5.5-428, P<.001) and diabetes mellitus (β: 29.7; 95% CI 1.1-763, P<.05) were independent predictors of mortality. Left ventricular torsion in acute MI setting is impaired and predicts subsequent LV remodeling at 6-month follow-up. © 2017, Wiley Periodicals, Inc.
Is speckle tracking actually helpful for cardiac resynchronization therapy?
Tanaka, Hidekazu; Hirata, Ken-Ichi
2016-06-01
What is the specific role of echocardiography in cardiac resynchronization therapy (CRT)? CRT has proven to be highly effective for improving symptoms and survival of patients with advanced heart failure (HF) and wide QRS. However, a significant minority of patients do not respond favorably to CRT on the basis of standard clinical selection criteria, including the electrocardiographic QRS width. Subsequently, echocardiographic assessment of left ventricular (LV) dyssynchrony has been considered useful for CRT for selected responders, but findings by multicenter studies suggest that its predictive value was not sufficiently robust to replace routine selection criteria for CRT. A more recent approach, however, using speckle-tracking echocardiography yields more accurate quantification of regional wall contraction. Speckle-tracking approaches have therefore generated a great deal of interest about their clinical applications for CRT. Although reports on speckle tracking have not been included in any recommendations as to whether patients should undergo CRT based on the current guidelines, speckle tracking can play an important supplementary part in CRT on the basis of a case-by-case clinical decision for challenging cases. Here, we review the strengths of speckle-tracking methods, and their current potential for clinical use in CRT.
NASA Technical Reports Server (NTRS)
Tilley, David G.
1987-01-01
NASA Space Shuttle Challenger SIR-B ocean scenes are used to derive directional wave spectra for which speckle noise is modeled as a function of Rayleigh random phase coherence downrange and Poisson random amplitude errors inherent in the Doppler measurement of along-track position. A Fourier filter that preserves SIR-B image phase relations is used to correct the stationary and dynamic response characteristics of the remote sensor and scene correlator, as well as to subtract an estimate of the speckle noise component. A two-dimensional map of sea surface elevation is obtained after the filtered image is corrected for both random and deterministic motions.
Methodological Gaps in Left Atrial Function Assessment by 2D Speckle Tracking Echocardiography
Rimbaş, Roxana Cristina; Dulgheru, Raluca Elena; Vinereanu, Dragoş
2015-01-01
The assessment of left atrial (LA) function is used in various cardiovascular diseases. LA plays a complementary role in cardiac performance by modulating left ventricular (LV) function. Transthoracic two-dimensional (2D) phasic volumes and Doppler echocardiography can measure LA function non-invasively. However, evaluation of LA deformation derived from 2D speckle tracking echocardiography (STE) is a new feasible and promising approach for assessment of LA mechanics. These parameters are able to detect subclinical LA dysfunction in different pathological condition. Normal ranges for LA deformation and cut-off values to diagnose LA dysfunction with different diseases have been reported, but data are still conflicting, probably because of some methodological and technical issues. This review highlights the importance of an unique standardized technique to assess the LA phasic functions by STE, and discusses recent studies on the most important clinical applications of this technique. PMID:26761370
Ni, Xian-Da; Huang, Jun; Hu, Yuan-Ping; Xu, Rui; Yang, Wei-Yu; Zhou, Li-Ming
2013-01-01
The aim of this study was to observe the rotation patterns at the papillary muscle plane in the Left Ventricle(LV) with normal subjects using two-dimensional speckle tracking imaging(2D-STI). We acquired standard of the basal, the papillary muscle and the apical short-axis images of the LV in 64 subjects to estimate the LV rotation motion by 2D-STI. The rotational degrees at the papillary muscle short-axis plane were measured at 15 different time points in the analysis of two heart cycles. There were counterclockwise rotation, clockwise rotation, and counterclockwise to clockwise rotation at the papillary muscle plane in the LV with normal subjects, respectively. The ROC analysis of the rotational degrees was performed at the papillary muscle short-axis plane at the peak LV torsion for predicting whether the turnaround point of twist to untwist motion pattern was located at the papillary muscle level. Sensitivity and specificity were 97% and 67%, respectively, with a cut-off value of 0.34°, and an area under the ROC curve of 0.8. At the peak LV torsion, there was no correlation between the rotational degrees at the papillary muscle short-axis plane and the LVEF in the normal subjects(r = 0.000, p = 0.998). In the study, we conclude that there were three rotation patterns at the papillary muscle short-axis levels, and the transition from basal clockwise rotation to apical counterclockwise rotation is located at the papillary muscle level.
Robust motion tracking based on adaptive speckle decorrelation analysis of OCT signal.
Wang, Yuewen; Wang, Yahui; Akansu, Ali; Belfield, Kevin D; Hubbi, Basil; Liu, Xuan
2015-11-01
Speckle decorrelation analysis of optical coherence tomography (OCT) signal has been used in motion tracking. In our previous study, we demonstrated that cross-correlation coefficient (XCC) between Ascans had an explicit functional dependency on the magnitude of lateral displacement (δx). In this study, we evaluated the sensitivity of speckle motion tracking using the derivative of function XCC(δx) on variable δx. We demonstrated the magnitude of the derivative can be maximized. In other words, the sensitivity of OCT speckle tracking can be optimized by using signals with appropriate amount of decorrelation for XCC calculation. Based on this finding, we developed an adaptive speckle decorrelation analysis strategy to achieve motion tracking with optimized sensitivity. Briefly, we used subsequently acquired Ascans and Ascans obtained with larger time intervals to obtain multiple values of XCC and chose the XCC value that maximized motion tracking sensitivity for displacement calculation. Instantaneous motion speed can be calculated by dividing the obtained displacement with time interval between Ascans involved in XCC calculation. We implemented the above-described algorithm in real-time using graphic processing unit (GPU) and demonstrated its effectiveness in reconstructing distortion-free OCT images using data obtained from a manually scanned OCT probe. The adaptive speckle tracking method was validated in manually scanned OCT imaging, on phantom as well as in vivo skin tissue.
Robust motion tracking based on adaptive speckle decorrelation analysis of OCT signal
Wang, Yuewen; Wang, Yahui; Akansu, Ali; Belfield, Kevin D.; Hubbi, Basil; Liu, Xuan
2015-01-01
Speckle decorrelation analysis of optical coherence tomography (OCT) signal has been used in motion tracking. In our previous study, we demonstrated that cross-correlation coefficient (XCC) between Ascans had an explicit functional dependency on the magnitude of lateral displacement (δx). In this study, we evaluated the sensitivity of speckle motion tracking using the derivative of function XCC(δx) on variable δx. We demonstrated the magnitude of the derivative can be maximized. In other words, the sensitivity of OCT speckle tracking can be optimized by using signals with appropriate amount of decorrelation for XCC calculation. Based on this finding, we developed an adaptive speckle decorrelation analysis strategy to achieve motion tracking with optimized sensitivity. Briefly, we used subsequently acquired Ascans and Ascans obtained with larger time intervals to obtain multiple values of XCC and chose the XCC value that maximized motion tracking sensitivity for displacement calculation. Instantaneous motion speed can be calculated by dividing the obtained displacement with time interval between Ascans involved in XCC calculation. We implemented the above-described algorithm in real-time using graphic processing unit (GPU) and demonstrated its effectiveness in reconstructing distortion-free OCT images using data obtained from a manually scanned OCT probe. The adaptive speckle tracking method was validated in manually scanned OCT imaging, on phantom as well as in vivo skin tissue. PMID:26600996
Diaphragm assessment by two dimensional speckle tracking imaging in normal subjects.
Orde, Sam R; Boon, Andrea J; Firth, Daniel G; Villarraga, Hector R; Sekiguchi, Hiroshi
2016-07-25
Conventionally, ultrasonographic assessment of diaphragm contractility has involved measuring respiratory changes in diaphragm thickness (thickening fraction) using B-mode or caudal displacement with M-mode. Two-dimensional speckle-tracking has been increasingly used to assess muscle deformation ('strain') in echocardiography. We sought to determine in a pilot study if this technology could be utilized to analyze diaphragmatic contraction. Fifty healthy adult volunteers with normal exercise capacity underwent ultrasound imaging. A linear array transducer was used for the assessment of diaphragm thickness, thickening fraction (TF), and strain in the right anterior axillary line at approximately the ninth intercostal space. A phased array transducer was applied subcostally for the assessment of diaphragm displacement on the right mid-clavicular line. Diaphragmatic images were recorded from the end of expiration through the end of inspiration at 60 % maximal inspiratory capacity. Diaphragm strain was analyzed off-line by speckle tracking imaging. Blinded inter- and intra-rater variability was tested in 10 cases. Mean right diaphragm thickness at end-expiration (±SD: standard deviation) was 0.24 cm (±0.1), with TF of 45.1 % (±12) at 60 % peak inspiratory effort. Mean right diaphragm caudal displacement was 4.9 cm (±1). Mean right diaphragm strain was -40.3 % (±9). A moderate correlation was seen between longitudinal strain and TF (R(2) 0.44, p < 0.0001). A weak correlation was seen between strain and caudal displacement (R(2) 0.14, p < 0.01), and an even weaker correlation was seen between caudal displacement and TF (R(2) 0.1, p = 0.04). Age, gender, and body mass index were not significantly associated with right diaphragm strain or TF. Although inter- and intra-rater variability was overall good for TF, caudal displacement, and strain (inter-rater R(2); 0.8, 0.9, and 0.7, respectively [p < 0.01], intra-rater R(2); 0.9, 0.7, and 0.9, respectively [p < 0.01]), strain values did have a slightly lower inter-rater repeatability. Diaphragmatic strain estimated by speckle tracking imaging was associated with conventional ultrasound measures of diaphragmatic function (TF and caudal displacement). Further clinical studies are warranted to investigate its clinical utility.
Wang, Yonghuai; Zhang, Yan; Ma, Chunyan; Guan, Zhengyu; Liu, Shuang; Zhang, Weixin; Li, Yuling; Yang, Jun
2016-06-01
Coronary slow-flow phenomenon (CSFP) is an angiographic diagnosis characterized by delayed coronary opacification in the absence of obstructive coronary artery disease. Currently, several investigators are focusing on ventricular function assessment in patients with CSFP; however, there is a paucity of data on their atrial function. This study was performed to evaluate left atrial (LA) and right atrial (RA) function in patients with CSFP. Eighty-two patients with CSFP and 55 controls without CSFP were enrolled in the study. Diagnosis of CSFP was made by thrombolysis in myocardial infarction frame count (TFC). The LA and RA global longitudinal strain and strain rate during systole (Ss, SRs), during early diastole (Se, SRe), and during late diastole (Sa, SRa) were measured using two-dimensional speckle tracking echocardiography. In the CSFP group, LA Se and SRe decreased, while LA Sa and SRa increased, compared with the control group. RA Se and SRe were lower in patients with CSFP than in the controls. LA conduit function decreased in patients with CSFP, while contractile function increased. RA conduit function also decreased in patients with CSFP. © 2016, Wiley Periodicals, Inc.
Rasmussen, Vibeke Guldbrand; Poulsen, Steen Hvitfeldt; Dupont, Erik; Ostergaard, Karen; Safikhany, Gholamhossein; Egeblad, Henrik
2008-11-01
Ergot-derived dopamine agonists (EDDA) induce fibrotic heart valve disease. We aimed to investigate whether EDDA treatment also affects left ventricular (LV) function. Myocardial function was evaluated in 110 Parkinson patients [mean age (63.4 +/- 9.0 years)] treated for at least 6 months with either EDDA (n = 71) or non-EDDA (n = 39). LV ejection fraction did not differ between EDDA and non-EDDA patients [63 +/- 4% vs. 65 +/- 4% (ns)]. There was no difference in prevalence of diastolic dysfunction between EDDA and non-EDDA patients [7% vs. 8% (ns)]. Finally, averaged LV systolic myocardial strain and longitudinal displacement analysed by means of two-dimensional speckle tracking showed no difference between EDDA and non-EDDA patients [strain: 19 +/- 3% vs. 19 +/- 2% (ns) and longitudinal displacement: 12 +/- 2 mm vs. 12 +/- 2 mm (ns)]. Elevated p-NT-proBNP was found in 38% of EDDA patients and in 59% of non-EDDA patients (ns). In contrast to the well-established association between EDDA treatment and valvular fibrosis, EDDA did not have a detectable adverse impact on myocardial systolic and diastolic function.
Tracking moving targets behind a scattering medium via speckle correlation.
Guo, Chengfei; Liu, Jietao; Wu, Tengfei; Zhu, Lei; Shao, Xiaopeng
2018-02-01
Tracking moving targets behind a scattering medium is a challenge, and it has many important applications in various fields. Owing to the multiple scattering, instead of the object image, only a random speckle pattern can be received on the camera when light is passing through highly scattering layers. Significantly, an important feature of a speckle pattern has been found, and it showed the target information can be derived from the speckle correlation. In this work, inspired by the notions used in computer vision and deformation detection, by specific simulations and experiments, we demonstrate a simple object tracking method, in which by using the speckle correlation, the movement of a hidden object can be tracked in the lateral direction and axial direction. In addition, the rotation state of the moving target can also be recognized by utilizing the autocorrelation of a speckle. This work will be beneficial for biomedical applications in the fields of quantitative analysis of the working mechanisms of a micro-object and the acquisition of dynamical information of the micro-object motion.
Inducible fluorescent speckle microscopy
Aguiar, Paulo; Belsley, Michael; Maiato, Helder
2016-01-01
The understanding of cytoskeleton dynamics has benefited from the capacity to generate fluorescent fiducial marks on cytoskeleton components. Here we show that light-induced imprinting of three-dimensional (3D) fluorescent speckles significantly improves speckle signal and contrast relative to classic (random) fluorescent speckle microscopy. We predict theoretically that speckle imprinting using photobleaching is optimal when the laser energy and fluorophore responsivity are related by the golden ratio. This relation, which we confirm experimentally, translates into a 40% remaining signal after speckle imprinting and provides a rule of thumb in selecting the laser power required to optimally prepare the sample for imaging. This inducible speckle imaging (ISI) technique allows 3D speckle microscopy to be performed in readily available libraries of cell lines or primary tissues expressing fluorescent proteins and does not preclude conventional imaging before speckle imaging. As a proof of concept, we use ISI to measure metaphase spindle microtubule poleward flux in primary cells and explore a scaling relation connecting microtubule flux to metaphase duration. PMID:26783303
Inducible fluorescent speckle microscopy.
Pereira, António J; Aguiar, Paulo; Belsley, Michael; Maiato, Helder
2016-01-18
The understanding of cytoskeleton dynamics has benefited from the capacity to generate fluorescent fiducial marks on cytoskeleton components. Here we show that light-induced imprinting of three-dimensional (3D) fluorescent speckles significantly improves speckle signal and contrast relative to classic (random) fluorescent speckle microscopy. We predict theoretically that speckle imprinting using photobleaching is optimal when the laser energy and fluorophore responsivity are related by the golden ratio. This relation, which we confirm experimentally, translates into a 40% remaining signal after speckle imprinting and provides a rule of thumb in selecting the laser power required to optimally prepare the sample for imaging. This inducible speckle imaging (ISI) technique allows 3D speckle microscopy to be performed in readily available libraries of cell lines or primary tissues expressing fluorescent proteins and does not preclude conventional imaging before speckle imaging. As a proof of concept, we use ISI to measure metaphase spindle microtubule poleward flux in primary cells and explore a scaling relation connecting microtubule flux to metaphase duration. © 2016 Pereira et al.
Shear wave arrival time estimates correlate with local speckle pattern.
Mcaleavey, Stephen A; Osapoetra, Laurentius O; Langdon, Jonathan
2015-12-01
We present simulation and phantom studies demonstrating a strong correlation between errors in shear wave arrival time estimates and the lateral position of the local speckle pattern in targets with fully developed speckle. We hypothesize that the observed arrival time variations are largely due to the underlying speckle pattern, and call the effect speckle bias. Arrival time estimation is a key step in quantitative shear wave elastography, performed by tracking tissue motion via cross-correlation of RF ultrasound echoes or similar methods. Variations in scatterer strength and interference of echoes from scatterers within the tracking beam result in an echo that does not necessarily describe the average motion within the beam, but one favoring areas of constructive interference and strong scattering. A swept-receive image, formed by fixing the transmit beam and sweeping the receive aperture over the region of interest, is used to estimate the local speckle pattern. Metrics for the lateral position of the speckle are found to correlate strongly (r > 0.7) with the estimated shear wave arrival times both in simulations and in phantoms. Lateral weighting of the swept-receive pattern improved the correlation between arrival time estimates and speckle position. The simulations indicate that high RF echo correlation does not equate to an accurate shear wave arrival time estimate-a high correlation coefficient indicates that motion is being tracked with high precision, but the location tracked is uncertain within the tracking beam width. The presence of a strong on-axis speckle is seen to imply high RF correlation and low bias. The converse does not appear to be true-highly correlated RF echoes can still produce biased arrival time estimates. The shear wave arrival time bias is relatively stable with variations in shear wave amplitude and sign (-20 μm to 20 μm simulated) compared with the variation with different speckle realizations obtained along a given tracking vector. We show that the arrival time bias is weakly dependent on shear wave amplitude compared with the variation with axial position/ local speckle pattern. Apertures of f/3 to f/8 on transmit and f/2 and f/4 on receive were simulated. Arrival time error and correlation with speckle pattern are most strongly determined by the receive aperture.
Shear Wave Arrival Time Estimates Correlate with Local Speckle Pattern
McAleavey, Stephen A.; Osapoetra, Laurentius O.; Langdon, Jonathan
2016-01-01
We present simulation and phantom studies demonstrating a strong correlation between errors in shear wave arrival time estimates and the lateral position of the local speckle pattern in targets with fully developed speckle. We hypothesize that the observed arrival time variations are largely due to the underlying speckle pattern, and call the effect speckle bias. Arrival time estimation is a key step in quantitative shear wave elastography, performed by tracking tissue motion via cross correlation of RF ultrasound echoes or similar methods. Variations in scatterer strength and interference of echoes from scatterers within the tracking beam result in an echo that does not necessarily describe the average motion within the beam, but one favoring areas of constructive interference and strong scattering. A swept-receive image, formed by fixing the transmit beam and sweeping the receive aperture over the region of interest, is used to estimate the local speckle pattern. Metrics for the lateral position of the speckle are found to correlate strongly (r>0.7) with the estimated shear wave arrival times both in simulations and in phantoms. Lateral weighting of the swept-receive pattern improved the correlation between arrival time estimates and speckle position. The simulations indicate that high RF echo correlation does not equate to an accurate shear wave arrival time estimate – a high correlation coefficient indicates that motion is being tracked with high precision, but the location tracked is uncertain within the tracking beam width. The presence of a strong on-axis speckle is seen to imply high RF correlation and low bias. The converse does not appear to be true – highly correlated RF echoes can still produce biased arrival time estimates. The shear wave arrival time bias is relatively stable with variations in shear wave amplitude and sign (−20 μm to 20 μm simulated) compared to the variation with different speckle realizations obtained along a given tracking vector. We show that the arrival time bias is weakly dependent on shear wave amplitude compared to the variation with axial position/local speckle pattern. Apertures of f/3 to f/8 on transmit and f/2 and f/4 on receive were simulated. Arrival time error and correlation with speckle pattern are most strongly determined by the receive aperture. PMID:26670847
Functional assessment of the diaphragm by speckle tracking ultrasound during inspiratory loading.
Oppersma, Eline; Hatam, Nima; Doorduin, Jonne; van der Hoeven, Johannes G; Marx, Gernot; Goetzenich, Andreas; Fritsch, Sebastian; Heunks, Leo M A; Bruells, Christian S
2017-11-01
Assessment of diaphragmatic effort is challenging, especially in critically ill patients in the phase of weaning. Fractional thickening during inspiration assessed by ultrasound has been used to estimate diaphragm effort. It is unknown whether more sophisticated ultrasound techniques such as speckle tracking are superior in the quantification of inspiratory effort. This study evaluates the validity of speckle tracking ultrasound to quantify diaphragm contractility. Thirteen healthy volunteers underwent a randomized stepwise threshold loading protocol of 0-50% of the maximal inspiratory pressure. Electric activity of the diaphragm and transdiaphragmatic pressures were recorded. Speckle tracking ultrasound was used to assess strain and strain rate as measures of diaphragm tissue deformation and deformation velocity, respectively. Fractional thickening was assessed by measurement of diaphragm thickness at end-inspiration and end-expiration. Strain and strain rate increased with progressive loading of the diaphragm. Both strain and strain rate were highly correlated to transdiaphragmatic pressure (strain r 2 = 0.72; strain rate r 2 = 0.80) and diaphragm electric activity (strain r 2 = 0.60; strain rate r 2 = 0.66). We conclude that speckle tracking ultrasound is superior to conventional ultrasound techniques to estimate diaphragm contractility under inspiratory threshold loading. NEW & NOTEWORTHY Transdiaphragmatic pressure using esophageal and gastric balloons is the gold standard to assess diaphragm effort. However, this technique is invasive and requires expertise, and the interpretation may be complex. We report that speckle tracking ultrasound can be used to detect stepwise increases in diaphragmatic effort. Strain and strain rate were highly correlated with transdiaphragmatic pressure, and therefore, diaphragm electric activity and speckle tracking might serve as reliable tools to quantify diaphragm effort in the future. Copyright © 2017 the American Physiological Society.
Levy, Philip T; El-Khuffash, Afif; Patel, Meghna D; Breatnach, Colm R; James, Adam T; Sanchez, Aura A; Abuchabe, Cristina; Rogal, Sarah R; Holland, Mark R; McNamara, Patrick J; Jain, Amish; Franklin, Orla; Mertens, Luc; Hamvas, Aaron; Singh, Gautam K
2017-07-01
The aim of this study was to determine the maturational changes in systolic ventricular strain mechanics by two-dimensional speckle-tracking echocardiography in extremely preterm neonates from birth to 1 year of age and discern the impact of common cardiopulmonary abnormalities on the deformation measures. In a prospective multicenter study of 239 extremely preterm infants (<29 weeks gestation at birth), left ventricular (LV) global longitudinal strain (GLS) and global longitudinal systolic strain rate (GLSRs), interventricular septal wall (IVS) GLS and GLSRs, right ventricular (RV) free wall longitudinal strain and strain rate, and segmental longitudinal strain in the RV free wall, LV free wall, and IVS were serially measured on days 1, 2, and 5 to 7, at 32 and 36 weeks postmenstrual age, and at 1 year corrected age (CA). Premature infants who developed bronchopulmonary dysplasia or had echocardiographic findings of pulmonary hypertension were analyzed separately. In uncomplicated preterm infants (n = 103 [48%]), LV GLS and GLSRs remained unchanged from days 5 to 7 to 1 year CA (P = .60 and P = .59). RV free wall longitudinal strain, RV free wall longitudinal strain rate, and IVS GLS and GLSRs significantly increased over the same time period (P < .01 for all measures). A significant base-to-apex (highest to lowest) segmental longitudinal strain gradient (P < .01) was seen in the RV free wall and a reverse apex-to-base gradient (P < .01) in the LV free wall. In infants with bronchopulmonary dysplasia and/or pulmonary hypertension (n = 119 [51%]), RV free wall longitudinal strain and IVS GLS were significantly lower (P < .01), LV GLS and GLSRs were similar (P = .56), and IVS segmental longitudinal strain persisted as an RV-dominant base-to-apex gradient from 32 weeks postmenstrual age to 1 year CA. This study tracks the maturational patterns of global and regional deformation by two-dimensional speckle-tracking echocardiography in extremely preterm infants from birth to 1 year CA. The maturational patterns are ventricular specific. Bronchopulmonary dysplasia and pulmonary hypertension leave a negative impact on RV and IVS strain, while LV strain remains stable. Copyright © 2017 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Satriano, Alessandro; Heydari, Bobak; Narous, Mariam; Exner, Derek V; Mikami, Yoko; Attwood, Monica M; Tyberg, John V; Lydell, Carmen P; Howarth, Andrew G; Fine, Nowell M; White, James A
2017-12-01
Two-dimensional (2D) strain analysis is constrained by geometry-dependent reference directions of deformation (i.e. radial, circumferential, and longitudinal) following the assumption of cylindrical chamber architecture. Three-dimensional (3D) principal strain analysis may overcome such limitations by referencing intrinsic (i.e. principal) directions of deformation. This study aimed to demonstrate clinical feasibility of 3D principal strain analysis from routine 2D cine MRI with validation to strain from 2D tagged cine analysis and 3D speckle tracking echocardiography. Thirty-one patients undergoing cardiac MRI were studied. 3D strain was measured from routine, multi-planar 2D cine SSFP images using custom software designed to apply 4D deformation fields to 3D cardiac models to derive principal strain. Comparisons of strain estimates versus those by 2D tagged cine, 2D non-tagged cine (feature tracking), and 3D speckle tracking echocardiography (STE) were performed. Mean age was 51 ± 14 (36% female). Mean LV ejection fraction was 66 ± 10% (range 37-80%). 3D principal strain analysis was feasible in all subjects and showed high inter- and intra-observer reproducibility (ICC range 0.83-0.97 and 0.83-0.98, respectively-p < 0.001 for all directions). Strong correlations of minimum and maximum principal strain were respectively observed versus the following: 3D STE estimates of longitudinal (r = 0.81 and r = -0.64), circumferential (r = 0.76 and r = -0.58) and radial (r = -0.80 and r = 0.63) strain (p < 0.001 for all); 2D tagged cine estimates of longitudinal (r = 0.81 and r = -0.81), circumferential (r = 0.87 and r = -0.85), and radial (r = -0.76 and r = 0.81) strain (p < 0.0001 for all); and 2D cine (feature tracking) estimates of longitudinal (r = 0.85 and -0.83), circumferential (r = 0.88 and r = -0.87), and radial strain (r = -0.79 and r = 0.84, p < 0.0001 for all). 3D principal strain analysis is feasible using routine, multi-planar 2D cine MRI and shows high reproducibility with strong correlations to 2D conventional strain analysis and 3D STE-based analysis. Given its independence from geometry-related directions of deformation this technique may offer unique benefit for the detection and prognostication of myocardial disease, and warrants expanded investigation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prentice, H. J.; Proud, W. G.
2006-07-28
A technique has been developed to determine experimentally the three-dimensional displacement field on the rear surface of a dynamically deforming plate. The technique combines speckle analysis with stereoscopy, using a modified angular-lens method: this incorporates split-frame photography and a simple method by which the effective lens separation can be adjusted and calibrated in situ. Whilst several analytical models exist to predict deformation in extended or semi-infinite targets, the non-trivial nature of the wave interactions complicates the generation and development of analytical models for targets of finite depth. By interrogating specimens experimentally to acquire three-dimensional strain data points, both analytical andmore » numerical model predictions can be verified more rigorously. The technique is applied to the quasi-static deformation of a rubber sheet and dynamically to Mild Steel sheets of various thicknesses.« less
Ni, Xian-Da; Huang, Jun; Hu, Yuan-Ping; Xu, Rui; Yang, Wei-Yu; Zhou, Li-Ming
2013-01-01
Background The aim of this study was to observe the rotation patterns at the papillary muscle plane in the Left Ventricle(LV) with normal subjects using two-dimensional speckle tracking imaging(2D-STI). Methods We acquired standard of the basal, the papillary muscle and the apical short-axis images of the LV in 64 subjects to estimate the LV rotation motion by 2D-STI. The rotational degrees at the papillary muscle short-axis plane were measured at 15 different time points in the analysis of two heart cycles. Results There were counterclockwise rotation, clockwise rotation, and counterclockwise to clockwise rotation at the papillary muscle plane in the LV with normal subjects, respectively. The ROC analysis of the rotational degrees was performed at the papillary muscle short-axis plane at the peak LV torsion for predicting whether the turnaround point of twist to untwist motion pattern was located at the papillary muscle level. Sensitivity and specificity were 97% and 67%, respectively, with a cut-off value of 0.34°, and an area under the ROC curve of 0.8. At the peak LV torsion, there was no correlation between the rotational degrees at the papillary muscle short-axis plane and the LVEF in the normal subjects(r = 0.000, p = 0.998). Conclusions In the study, we conclude that there were three rotation patterns at the papillary muscle short-axis levels, and the transition from basal clockwise rotation to apical counterclockwise rotation is located at the papillary muscle level. PMID:24376634
Haberka, Maciej; Liszka, Jerzy; Kozyra, Andrzej; Finik, Maciej; Gąsior, Zbigniew
2015-03-01
The aim of the study was to evaluate the left ventricle (LV) function with speckle tracking echocardiography (STE) and to assess its relation to prognosis in patients after acute myocardial infarction (AMI). Sixty-three patients (F/M = 16/47 pts; 62.33 ± 11.85 years old) with AMI (NSTEMI/STEMI 24/39 pts) and successful percutaneous coronary intervention (PCI) with stent implantation (thrombolysis in myocardial infarction; TIMI 3 flow) were enrolled in this study. All patients underwent baseline two-dimensional conventional echocardiography and STE 3 days (baseline) and 30 days after PCI. All patients were followed up for cardiovascular clinical endpoints, major adverse cardiovascular endpoint (MACE), and functional status (Canadian Cardiovascular Society and New York Heart Association). During the follow-up (31.9 ± 5.1 months), there were 3 cardiovascular deaths, 15 patients had AMI, 2 patients had cerebral infarction, 24 patients reached the MACE. Baseline LV torsion (P = 0.035), but none of the other strain parameters were associated with the time to first unplanned cardiovascular hospitalization. Univariate analysis showed that baseline longitudinal two-chamber and four-chamber strain (sLa2 0 and sLa4 0) and the same parameters obtained 30 days after the AMI together with transverse four-chamber strain (sLa2 30, sLa4 30, and sTa4 30) were significantly associated with combined endpoint (MACE). The strongest association in the univariate analysis was found for the baseline sLa2. However, in multivariable analysis only a left ventricular remodeling (LVR - 27% pts) was significantly associated with MACE and strain parameters were not associated with the combined endpoint. The assessment of LV function with STE may improve cardiovascular risk prediction in postmyocardial infarction patients. © 2014, Wiley Periodicals, Inc.
Ishizu, Tomoko; Seo, Yoshihiro; Igarashi, Miyako; Sekiguchi, Yukio; Machino-Ohtsuka, Tomoko; Ogawa, Kojiro; Kuroki, Kenji; Yamamoto, Masahiro; Nogami, Akihiko; Kawakami, Yasushi; Aonuma, Kazutaka
2016-06-01
We have developed a noninvasive isochrone activation imaging (AI) system with 3-dimensional (3D) speckle tracking echocardiography (STE), which allows visualization of the wavefront image of mechanical propagation of the accessory pathway (ACP) in Wolff-Parkinson-White syndrome. Patients with manifest Wolff-Parkinson-White syndrome were imaged in 3D-STE AI mode, which quantified the time from QRS onset to regional endocardial deformation. In 2 patients with left- and right-side ACP, we confirmed that intraoperative contact endocardial electric mapping and the 3D-STE AI system showed comparable images pre- and postablation. In normal heart assessment by 3D-echo AI, the earliest activation sites were found at the attachment of the papillary muscles in the left ventricle and midseptum in the right ventricle, and none showed earliest activation at the peri-atrioventricular valve annuli. An analyzer who was unaware of the clinical information assessed 39 ACP locations in 38 Wolff-Parkinson-White syndrome patients using 3D-STE. All showed abnormal perimitral or tricuspid annular activations, and the location of 34 ACP (87%) showed agreement with the successful ablation sites within a 2-o'clock range. Especially for left free wall ACP, 17/18 (94%) showed consistency with the ablation site within a 2 o'clock range. Among 15 ACP at the ventricular septum, 9 (60%) showed early local activation in both right and left sides of the septum. Isochrone AI with 3D-STE may be a promising noninvasive imaging tool to assess cardiac synchronized activation in normal hearts and detect abnormal breakthrough of mechanical activation from both atrioventricular annuli in Wolff-Parkinson-White syndrome. © 2016 American Heart Association, Inc.
Badano, Luigi P; Cucchini, Umberto; Muraru, Denisa; Al Nono, Osama; Sarais, Cristiano; Iliceto, Sabino
2013-03-01
Since there is insufficient data available about the inter-vendor consistency of three-dimensional (3D) speckle-tracking (STE) measurements, we undertook this study to (i) assess the inter-vendor consistency of 3D LV global strain values obtained using two different scanners; (ii) identify the sources of inter-vendor inconsistencies, if any; and (iii) compare their respective intrinsic variability. Sixty patients (38 ± 12 years, 64% males) with a wide range of LV end-diastolic volumes (from 74 to 205 ml) and ejection fractions (from 17 to 70%) underwent two 3D LV data set acquisitions using VividE9 and Artida ultrasound systems. Global longitudinal (Lε), radial (Rε), circumferential (Cε) and area (Aε) strain values were obtained offline using the corresponding 3D STE softwares. Despite being significantly different, Lε showed the closest values between the two platforms (bias = 1.5%, limits of agreement (LOA) from -2.9 to -5.9%, P < 0.05). Artida produced significantly higher values of both Cε and Aε than VividE9 (bias = 6.6, LOA: -14.1 to 0.9%, and bias = 6.0, LOA = -28.2-8.6%, respectively, P < 0.001). Conversely, Rε values obtained with Artida were significantly lower than those measured using VividE9 platform (bias = -24.2, LOA: 1.5-49.9, P < 0.001). All strain components showed good reproducibility (intra-class correlation coefficients: 0.82-0.98), except for Rε by Artida, which showed only a moderate reproducibility. Apart from Lε, the inter-vendor agreement of Rε, Cε and Aε measured with Artida and VividE9 was poor. Reference values should be specific for each system and baseline and follow-up data in longitudinal studies should be obtained using the same 3D STE platform.
Gondim Teixeira, Pedro Augusto; Badr, Sammy; Hossu, Gabriela; Lefebvre, Guillaume; Abou Arab, Waled; Blum, Alain; Cotten, Anne
2017-12-01
To evaluate the feasibility and potential clinical applicability of speckle-tracking sonography for the dynamic evaluation of the scapholunate diastasis during stress manoeuvres. Two readers used speckle tracking sonography to evaluate scapholunate diastasis during a clenching fist manoeuver in 30 normal wrists. Scapholunate peak strain, mean scapholunate diastasis and the diastasis variation coefficient were analysed. IRB exemption was granted for this study. Conventional and stress wrist radiographs of 26 patients with and without a scapholunate ligament tear were retrospectively analysed to ascertain the range of variation in scapholunate diastasis. Speckle-tracking parameters in normal wrists were similar between the two readers (p > 0.2061). The maximal scapholunate peak strain during stress was relatively low (<0.34-0.47 mm). The normal radiographic diastasis amplitude was similar to maximal strain peak values in normal volunteers (0.49 ± 0.51 mm). The radiographic diastasis amplitude in cases of scapholunate ligament tears was 1.48 ± 0.78 mm, which was higher than the 95% confidence interval of the scapholunate gap peak strain. Speckle-tracking sonography could represent an interesting alternative for stress evaluation of the scapholunate ligament in patients with scapholunate diastasis. • Speckle-tracking sonography can assess scapholunate diastasis under stress testing. • Scapholunate gap shows little variation under stress in healthy volunteers. • Scapholunate gap measurements are influenced by grip strength. • Sex and BMI have a significant influence on strain measurements.
NASA Astrophysics Data System (ADS)
Itatani, Keiichi; Okada, Takashi; Uejima, Tokuhisa; Tanaka, Tomohiko; Ono, Minoru; Miyaji, Kagami; Takenaka, Katsu
2013-07-01
We have developed a system to estimate velocity vector fields inside the cardiac ventricle by echocardiography and to evaluate several flow dynamical parameters to assess the pathophysiology of cardiovascular diseases. A two-dimensional continuity equation was applied to color Doppler data using speckle tracking data as boundary conditions, and the velocity component perpendicular to the echo beam line was obtained. We determined the optimal smoothing method of the color Doppler data, and the 8-pixel standard deviation of the Gaussian filter provided vorticity without nonphysiological stripe shape noise. We also determined the weight function at the bilateral boundaries given by the speckle tracking data of the ventricle or vascular wall motion, and the weight function linear to the distance from the boundary provided accurate flow velocities not only inside the vortex flow but also around near-wall regions on the basis of the results of the validation of a digital phantom of a pipe flow model.
NASA Astrophysics Data System (ADS)
Malone, Joseph D.; El-Haddad, Mohamed T.; Tye, Logan A.; Majeau, Lucas; Godbout, Nicolas; Rollins, Andrew M.; Boudoux, Caroline; Tao, Yuankai K.
2016-03-01
Scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT) benefit clinical diagnostic imaging in ophthalmology by enabling in vivo noninvasive en face and volumetric visualization of retinal structures, respectively. Spectrally encoding methods enable confocal imaging through fiber optics and reduces system complexity. Previous applications in ophthalmic imaging include spectrally encoded confocal scanning laser ophthalmoscopy (SECSLO) and a combined SECSLO-OCT system for image guidance, tracking, and registration. However, spectrally encoded imaging suffers from speckle noise because each spectrally encoded channel is effectively monochromatic. Here, we demonstrate in vivo human retinal imaging using a swept source spectrally encoded scanning laser ophthalmoscope and OCT (SSSESLO- OCT) at 1060 nm. SS-SESLO-OCT uses a shared 100 kHz Axsun swept source, shared scanner and imaging optics, and are detected simultaneously on a shared, dual channel high-speed digitizer. SESLO illumination and detection was performed using the single mode core and multimode inner cladding of a double clad fiber coupler, respectively, to preserve lateral resolution while improving collection efficiency and reducing speckle contrast at the expense of confocality. Concurrent en face SESLO and cross-sectional OCT images were acquired with 1376 x 500 pixels at 200 frames-per-second. Our system design is compact and uses a shared light source, imaging optics, and digitizer, which reduces overall system complexity and ensures inherent co-registration between SESLO and OCT FOVs. En face SESLO images acquired concurrent with OCT cross-sections enables lateral motion tracking and three-dimensional volume registration with broad applications in multivolume OCT averaging, image mosaicking, and intraoperative instrument tracking.
de Amorim Corrêa, Ricardo; de Oliveira, Fernanda Brito; Barbosa, Marcia M; Barbosa, Jose Augusto A; Carvalho, Taís Soares; Barreto, Michele Campos; Campos, Frederico Thadeu A F; Nunes, Maria Carmo Pereira
2016-09-01
Pulmonary arterial hypertension (PAH) is characterized by elevated mean pulmonary arterial pressure with abnormal right ventricular (RV) pressure overload that may alter left ventricular (LV) function. The aim of this study was to assess the impact of RV pressure overload on LV function in PAH patients using two-dimensional (2D) speckle tracking strain. The study enrolled 37 group 1 PAH patients and 38 age- and gender-matched healthy controls. LV longitudinal and radial 2D strains were measured with and without including the ventricular septum. Six-minute walk test (6MWT) and brain natriuretic peptide (BNP) levels were also obtained in patients with PAH. The mean age of patients was 46.4 ± 14.8 years, 76% women, and 16 patients (43%) had schistosomiasis. Sixteen patients (43%) were in WHO class III or IV under specific treatment for PAH. The overall 6MWT distance was 441 meters, and the BNP levels were 80 pg/mL. Patients with PAH more commonly presented with LV diastolic dysfunction and impairment of RV function when compared to controls. LV global longitudinal and radial strains were lower in patients than in controls (-17.9 ± 2.8 vs. -20.5 ± 1.9; P < 0.001 and 30.8 ± 10.5 vs. 49.8 ± 15.4; P < 0.001, respectively). After excluding septal values, LV longitudinal and radial strains remained lower in patients than in controls. The independent factors associated with global LV longitudinal strain were LV ejection fraction, RV fractional area change, and tricuspid annular systolic motion. This study showed impaired LV contractility in patients with PAH assessed by speckle tracking strain, irrespective of ventricular septal involvement. Global LV longitudinal strain was associated independently with RV fractional area change and tricuspid annular systolic motion, after adjustment for LV ejection fraction. © 2016, Wiley Periodicals, Inc.
Hwang, In-Chang; Cho, Goo-Yeong; Yoon, Yeonyee E; Park, Jin Joo
2018-01-01
The prognostic value of left ventricular (LV) global strain and twist in patients with left bundle branch block (LBBB) is not fully investigated. The aim of this study was to investigate the association between myocardial strain and twist and cardiovascular events in patients with LBBB, as assessed using two-dimensional speckle-tracking echocardiography. A total of 269 patients with LBBB (mean age, 69.5 ± 10.9 years; 46.8% men) were retrospectively identified. Using speckle-tracking, LV global longitudinal strain (GLS), global circumferential strain, and twist were measured. Association between LV global function and a composite of cardiovascular mortality and hospitalization for heart failure was compared with clinical risk factors, LV ejection fraction (LVEF), and other echocardiographic parameters. During a median of 27.5 months (interquartile range, 12.8-43.9 months), the composite end point occurred in 55 patients (20.4%). In univariate analyses, diabetes mellitus, chronic kidney disease, ischemic etiology of LBBB, dilated left atrium, reduced LVEF, dilated left ventricle, and impaired LV global strain (GLS > -12.2%, global circumferential strain > -11.8%, and twist < 6.5°) showed associations with the composite end point. In multivariate analyses, GLS was significantly associated with the composite end point (adjusted hazard ratio, 4.697; 95% CI, 1.344-16.413; P = .015), whereas global circumferential strain, twist, and LVEF were not. GLS showed an additive association with poor prognosis over clinical risk factors and other echocardiographic parameters, including LVEF. Patients with preserved LVEFs (≥40%) but impaired GLS (>-12.2%) had a larger number of clinical events than those with impaired LVEFs but preserved GLS. Among patients with LBBB, GLS can provide better risk stratification than LVEF or other echocardiographic parameters. Copyright © 2017 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Borgia, Francesco; Pezzullo, Enrica; Schiano Lomoriello, Vincenzo; Sorrentino, Regina; Lo Iudice, Francesco; Cocozza, Sara; Della Casa, Roberto; Parenti, Giancarlo; Strisciuglio, Pietro; Trimarco, Bruno; Galderisi, Maurizio
2017-02-01
Mucopolysaccharidoses (MPS) are inherited lysosomal storage disorders caused by deficiency of required glycosaminoglycans breakdown enzymes, inducing cardiac involvement. Little is known about myocardial deformation involvement in MPS. Our aim was to assess biventricular structure and function in asymptomatic children with MPS using standard echo Doppler and 2D speckle tracking (STE). Fifteen MPS children (one type I, six type II, three type III A, one III B, three IV A, one VI), asymptomatic for cardiac symptoms, and 15 age and sex-matched healthy controls underwent echo Doppler and STE. Left ventricular (LV) wall thicknesses, diameters, and mass were normalized by z-score. LV global longitudinal strain (GLS), global circumferential strain (GCS), global radial strain (GRS) at papillary muscles, LV twisting, and right ventricular (RV) GLS were measured. The two groups were comparable for body mass index, heart rate, and blood pressure. LV mass index and relative wall thickness were higher in MPS. Ejection fraction (EF), and s' velocity did not differ between the two groups. E/A ratio was lower and E/e' higher in MPS. Tricuspid annular plane systolic excursion, RV s' and e' were lower in MPS. LV GLS did not differ between the two groups, but GCS (P=.014), GRS (P=.023), twisting (P=.012), and RV GLS (P<.001) were lower in the MPS group. LV strain abnormalities are detectable in MPS pediatric patients, independently of MPS type, when EF is still normal. RV GLS is also involved consensually with TAPSE reduction. STE can be useful for detection of subclinical myocardial damage in MPS. © 2017, Wiley Periodicals, Inc.
Three-dimensional displacement measurement by fringe projection and speckle photography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barrientos, B.; Garcia-Marquez, J.; Cerca, M.
2008-04-15
3D displacement fields are measured by the combination of two optical methods, fringe projection and speckle photography. The use of only one camera recording the necessary information implies that no calibration procedures are necessary as is the case in techniques based on stereoscopy. The out-of-plane displacement is measured by fringe projection whereas speckle photography yields the 2-D in-plane component. To show the feasibility of the technique, we analyze a detailed morphological spatio-temporal evolution of a model of the Earth's crust while subjected to compression forces. The results show that the combination of fringe projection and speckle photography is well suitedmore » for this type of studies.« less
Dickson, D; Shave, R; Rishniw, M; Patteson, M
2017-08-01
To establish reference intervals for echocardiographic measures of longitudinal left ventricular function in adult English Springer spaniel (ESS) dogs. This study involved 42 healthy adult ESS. Animals were prospectively recruited from a general practice population in the United Kingdom. Dogs were examined twice, at least 12 months apart, to exclude dogs with progressive cardiac disease. Mitral annular plane systolic excursion, tissue Doppler imaging mitral annular velocities and two-dimensional speckle-tracking echocardiographic left ventricular longitudinal strain and strain rate were measured. Intraoperator and intraobserver variability were examined and reference intervals were calculated. The potential effects of body weight, age and heart rate on these variables were examined. Intraoperator and intraobserver variability was <10% for all parameters except tissue Doppler imaging E' (the peak velocity of early diastolic mitral annular motion as determined by pulsed wave Doppler) and two-dimensional speckle-tracking echocardiographic variables, which were all <20%. Thirty-nine dogs were used to create reference intervals. Significant (but mostly weak) effects of age, heart rate and body weight on were detected. Reference intervals were similar to previously published values in different breeds. Breed specific reference intervals for measures of longitudinal left ventricular function in the ESS are presented. Copyright © 2017 Elsevier B.V. All rights reserved.
Trache, Tudor; Stöbe, Stephan; Tarr, Adrienn; Pfeiffer, Dietrich; Hagendorff, Andreas
2014-12-01
Comparison of 3D and 2D speckle tracking performed on standard 2D and triplane 2D datasets of normal and pathological left ventricular (LV) wall-motion patterns with a focus on the effect that 3D volume rate (3DVR), image quality and tracking artifacts have on the agreement between 2D and 3D speckle tracking. 37 patients with normal LV function and 18 patients with ischaemic wall-motion abnormalities underwent 2D and 3D echocardiography, followed by offline speckle tracking measurements. The values of 3D global, regional and segmental strain were compared with the standard 2D and triplane 2D strain values. Correlation analysis with the LV ejection fraction (LVEF) was also performed. The 3D and 2D global strain values correlated good in both normally and abnormally contracting hearts, though systematic differences between the two methods were observed. Of the 3D strain parameters, the area strain showed the best correlation with the LVEF. The numerical agreement of 3D and 2D analyses varied significantly with the volume rate and image quality of the 3D datasets. The highest correlation between 2D and 3D peak systolic strain values was found between 3D area and standard 2D longitudinal strain. Regional wall-motion abnormalities were similarly detected by 2D and 3D speckle tracking. 2DST of triplane datasets showed similar results to those of conventional 2D datasets. 2D and 3D speckle tracking similarly detect normal and pathological wall-motion patterns. Limited image quality has a significant impact on the agreement between 3D and 2D numerical strain values.
Kim, Chee Hae; Wang, Shuang; Park, Jun-Bean; Jung, Keun-Hwa; Yoon, Yeonyee E; Lee, Seung-Pyo; Kim, Hyung-Kwan; Kim, Yong-Jin; Cho, Goo-Yeong; Sohn, Dae-Won
2018-03-07
Speckle-tracking imaging has been introduced for the precise assessment of vessel mechanics. However, there are no data on the role of this imaging tool in assessing the changes in vasculature with statin therapy, which is known to enhance vascular elasticity. This study was a prospective study including 48 statin-naïve patients (age, 58.2±8.4 years; 29.2% male) with hypercholesterolemia. Circumferential carotid artery strain (CAS) and stiffness index (β 2 ) were measured using speckle-tracking imaging before and after 3 months of high-dose pitavastatin treatment (4 mg daily). For the comparison, we measured conventional carotid elasticity parameters and intima-media thickness using B-mode ultrasound at the same time points. Compared with baseline, there was significant improvement in circumferential CAS (2.98%±1.18% to 3.40%±1.43%, p=0.008) and β 2 (0.19±0.07 to 0.17±0.08, p=0.047) after statin therapy. Contrariwise, there were no significant changes in all conventional carotid elasticity metrics and intima-media thickness. When stratifying patients into two subgroups by 10 year atherosclerotic cardiovascular disease (ASCVD) risk, speckle-tracking-derived circumferential CAS and β 2 improved significantly only in patients with ASCVD risk ≥ 7.5%. Short-term treatment with high-dose pitavastatin improved carotid artery elasticity measured by speckle-tracking method, but not conventional parameters by B-mode ultrasound. Speckle-tracking-based measurements may allow the early noninvasive assessment of statin effects on vascular function in hypercholesterolemic patients.
Sade, Leyla Elif; Kozan, Hatice; Eroglu, Serpil; Pirat, Bahar; Aydinalp, Alp; Sezgin, Atilla; Muderrisoglu, Haldun
2017-02-01
Residual pulmonary hypertension challenges the right ventricular function and worsens the prognosis in heart transplant recipients. The complex geometry of the right ventricle complicates estimation of its function with conventional transthoracic echocardiography. We evaluated right ventricular function in heart transplant recipients with the use of 3-dimensional echocardiography in relation to systolic pulmonary artery pressure. We performed 32 studies in 26 heart transplant patients, with 6 patients having 2 studies at different time points with different pressures and thus included. Right atrial volume, tricuspid annular plane systolic excursion, peak systolic annular velocity, fractional area change, and 2-dimensional speckle tracking longitudinal strain were obtained by 2-dimensional and tissue Doppler imaging. Three-dimensional right ventricular volumes, ejection fraction, and 3-dimensional right ventricular strain were obtained from the 3-dimensional data set by echocardiographers. Systolic pulmonary artery pressure was obtained during right heart catheterization. Overall mean systolic pulmonary artery pressure was 26 ± 7 mm Hg (range, 14-44 mmHg). Three-dimensional end-diastolic (r = 0.75; P < .001) and end-systolic volumes (r = 0.55; P = .001)correlated well with systolic pulmonary artery pressure. Right ventricular ejection fraction and right atrium volume also significantly correlated with systolic pulmonary artery pressure (r = 0.49 and P = .01 for both). However, right ventricular 2- and 3-dimensional strain, tricuspid annular plane systolic excursion, and tricuspid annular velocity did not. The effects of pulmonary hemodynamic burden on right ventricular function are better estimated by a 3-dimensional volume evaluation than with 3-dimensional longitudinal strain and other 2-dimensional and tissue Doppler measurements. These results suggest that the peculiar anatomy of the right ventricle necessitates 3-dimensional volume quantification in heart transplant recipients in relation to residual pulmonary hypertension.
Progress in high temperature speckle-shift strain measurement system
NASA Technical Reports Server (NTRS)
Lant, Christian T.; Barranger, John P.
1990-01-01
A fast, easy to use speckle tracking system is under development for the speckle-shift strain measurement technique. Preliminary correlation tests on wire specimens show strong correlations of well-developed speckle patterns. Stable cross-correlations were obtained from a tungsten filament at 2480 C. An analysis of the optical system determines the minimum required sampling frequency of the speckle pattern to be 2.55 pixels per speckle.
Left atrium function by 2D speckle tracking in aortic valve disease.
Salas-Pacheco, Jose L; Ávila-Vanzzini, Nydia; Eugenia, Ruiz-Esparza M; Arias-Godínez, Jose A
2016-12-01
A paucity of data exists about left atrium (LA) function in aortic valve stenosis (AS) or regurgitation (AR). Two-dimensional speckle tracking echocardiography allows the noninvasive study of LA functional disturbances in aortic valve disease and their impact in the development of pulmonary hypertension (PH). Consecutive patients with moderate or severe AS or AR were included. Left ventricle (LV) and LA speckle tracking strain quantification was performed. We included 42 patients with AS and 30 with AR. Differences were not found in LA volumes and strain in AS or AR. The LA volumetric derangements parallel the decrease in LA longitudinal strain. Maximum LA volume, minimum LA volume, and indexed LA volume were higher in severe valvular disease (SVD) than in moderate [23 cc (P=.018, IC 95% : 4-41), 16 cc (P=.035, IC 95% : 2-31), and 14 cc (P=.022, IC 95% : 2-25), respectively], occurred in the same way with LA strain in the conduit (6.3%, P=.034, IC 95% : 1-12) and reservoir (7.1%, P=.04, IC 95% : 2-14) phases. In multivariable model, strain of reservoir phase was the variable mainly associated with PH; each decrease in one unit of strain of reservoir phase increased 6% the PH probability (OR: 1.06, P=.01). This study demonstrates that in patients with AS and AR, the LA has a similar behavior and that exist a close correlation between LA volumetric and functional parameters. The variable mainly associated with PH was LA strain of reservoir phase. © 2016, Wiley Periodicals, Inc.
Hodzic, Amir; Chayer, Boris; Wang, Diya; Porée, Jonathan; Cloutier, Guy; Milliez, Paul; Normand, Hervé; Garcia, Damien; Saloux, Eric; Tournoux, Francois
2018-01-01
This study aimed to test the accuracy of a speckle tracking algorithm to assess myocardial deformation in a large range of heart rates and strain magnitudes compared to sonomicrometry. Using a tissue-mimicking phantom with cyclic radial deformation, radial strain derived from speckle tracking (RS-SpT) of the upper segment was assessed in short axis view by conventional echocardiography (Vivid q, GE) and post-processed with clinical software (EchoPAC, GE). RS-SpT was compared with radial strain measured simultaneously by sonomicrometers (RS-SN). Radial strain was assessed with increasing deformation rates (60 to 160 beats/min) and increasing pulsed volumes (50 to 100 ml/beat) to simulate physiological changes occurring during stress echocardiography. There was a significant correlation (R2 = 0.978, P <0.001) and a close agreement (bias ± 2SD, 0.39 ± 1.5%) between RS-SpT and RS-SN. For low strain values (<15%), speckle tracking showed a small but significant overestimation of radial strain compared to sonomicrometers. Two-way analysis of variance did not show any significant effect of the deformation rate. For RS-SpT, the feasibility was excellent and the intra- and inter-observer variability were low (the intraclass correlation coefficients were 0.96 and 0.97, respectively). Speckle tracking demonstrated a good correlation with sonomicrometry for the assessment of radial strain independently of the heart rate and strain magnitude in a physiological range of values. Though speckle tracking seems to be a reliable and reproducible technique to assess myocardial deformation variations during stress echocardiography, further studies are mandated to analyze the impact of angulated and artefactual out-of-plane motions and inter-vendor variability.
Speckle tracking imaging in inflammatory heart diseases.
Leitman, Marina; Vered, Zvi; Tyomkin, Vladimir; Macogon, Boris; Moravsky, Gil; Peleg, Eli; Copel, Laurian
2018-05-01
Accurate diagnosis of acute myocarditis is important for the prognosis and risk stratification of these patients. Cardiac magnetic resonance (CMR) has become a major modality for diagnosis of myocarditis, but not widely available. In this study, we tried to evaluate regional and global longitudinal strain by speckle tracking echocardiography in patients with acute inflammatory myocardial diseases in correlation with CMR. Patients with suspected acute myocarditis were recruited prospectively. Clinical diagnosis was established based on clinical, electrocardiographic, laboratory and conventional echocardiographic data. All patients underwent CMR and repeat echocardiographic examination within 24 h of CMR. Echocardiographic examinations were analyzed offline with speckle tracking imaging software. Thirty-two patients with acute perimyocarditis and myopericarditis were included. Mean age was 29 ± 8, 30 males. All patients presented with chest pain and an abnormal electrocardiogram, in 28 ST elevation was found. Troponin was elevated in 30 and was 0.7 ± 0.5 ng/ml. Creatine kinase was 487 ± 319 U. LVEF was 56 ± 5%. Wall motion abnormalities were present in postero-lateral (53%), and inferior wall (21%). Delayed enhancement on CMR was found in 29 patients. Echocardiographic EF based on speckle tracking imaging correlated with CMR calculated EF. There was a positive correlation between the amplitude of regional strain and delayed enhancement, r = 0.52. Sensitivity and specificity of regional strain for prediction of delayed enhancement was 85 and 73% respectively. Speckle tracking imaging can help in the diagnosis of acute myocarditis when CMR is not readily available. Speckle tracking imaging based EF correlates with CMR calculated LVEF and with global strain.
Chayer, Boris; Wang, Diya; Porée, Jonathan; Cloutier, Guy; Milliez, Paul; Normand, Hervé; Garcia, Damien; Saloux, Eric; Tournoux, Francois
2018-01-01
Aim This study aimed to test the accuracy of a speckle tracking algorithm to assess myocardial deformation in a large range of heart rates and strain magnitudes compared to sonomicrometry. Methods and results Using a tissue-mimicking phantom with cyclic radial deformation, radial strain derived from speckle tracking (RS-SpT) of the upper segment was assessed in short axis view by conventional echocardiography (Vivid q, GE) and post-processed with clinical software (EchoPAC, GE). RS-SpT was compared with radial strain measured simultaneously by sonomicrometers (RS-SN). Radial strain was assessed with increasing deformation rates (60 to 160 beats/min) and increasing pulsed volumes (50 to 100 ml/beat) to simulate physiological changes occurring during stress echocardiography. There was a significant correlation (R2 = 0.978, P <0.001) and a close agreement (bias ± 2SD, 0.39 ± 1.5%) between RS-SpT and RS-SN. For low strain values (<15%), speckle tracking showed a small but significant overestimation of radial strain compared to sonomicrometers. Two-way analysis of variance did not show any significant effect of the deformation rate. For RS-SpT, the feasibility was excellent and the intra- and inter-observer variability were low (the intraclass correlation coefficients were 0.96 and 0.97, respectively). Conclusions Speckle tracking demonstrated a good correlation with sonomicrometry for the assessment of radial strain independently of the heart rate and strain magnitude in a physiological range of values. Though speckle tracking seems to be a reliable and reproducible technique to assess myocardial deformation variations during stress echocardiography, further studies are mandated to analyze the impact of angulated and artefactual out-of-plane motions and inter-vendor variability. PMID:29584751
NASA Astrophysics Data System (ADS)
Dhutia, Niti M.; Zolgharni, Massoud; Willson, Keith; Cole, Graham; Nowbar, Alexandra N.; Manisty, Charlotte H.; Francis, Darrel P.
2014-03-01
Some of the challenges with tissue Doppler measurement include: apparent inconsistency between manufacturers, uncertainty over which part of the trace to make measurements and a lack of calibration of measurements. We develop and test tools to solve these problems in echocardiography laboratories. We designed and constructed an actuator and phantom setup to produce automatic reproducible motion, and used it to compare velocities measured using 3 echocardiographic modalities: M-mode, speckle tracking, and tissue Doppler, against a non-ultrasound, optical gold standard. In the clinical phase, 25 patients underwent M-mode, speckle tracking and tissue Doppler measurements of tissue velocities. In-vitro, the M-mode and speckle tracking velocities were concordant with optical assessment. Of the three possible tissue Doppler measurement conventions (outer, middle and inner line) only the middle line agreed with the optical assessment (discrepancy -0.20 (95% confidence interval -0.44 to 0.03)cm/s, p=0.11, outer +5.19(4.65 to 5.73)cm/s, p<0.0001, inner -6.26(-6.87 to -5.65)cm/s, p<0.0001). All 4 studied manufacturers showed a similar pattern. M-mode was therefore chosen as the in-vivo gold standard. Clinical measurements of tissue velocities by speckle tracking and the middle line of the tissue Doppler were concordant with M-mode, while the outer line significantly overestimated (+1.27(0.96 to 1.59)cm/s, p<0.0001) and the inner line underestimated (-1.81(-2.11 to -1.52)cm/s, p<0.0001). Echocardiographic velocity measurements can be calibrated by simple, inexpensive tools. We found that the middle of the tissue Doppler trace represents velocity correctly. Echocardiographers requiring velocities to match between different equipment, settings or modalities should use the middle line as the "guideline".
Hrabovský, Miroslav
2014-01-01
The purpose of the study is to show a proposal of an extension of a one-dimensional speckle correlation method, which is primarily intended for determination of one-dimensional object's translation, for detection of general in-plane object's translation. In that view, a numerical simulation of a displacement of the speckle field as a consequence of general in-plane object's translation is presented. The translation components a x and a y representing the projections of a vector a of the object's displacement onto both x- and y-axes in the object plane (x, y) are evaluated separately by means of the extended one-dimensional speckle correlation method. Moreover, one can perform a distinct optimization of the method by reduction of intensity values representing detected speckle patterns. The theoretical relations between the translation components a x and a y of the object and the displacement of the speckle pattern for selected geometrical arrangement are mentioned and used for the testifying of the proposed method's rightness. PMID:24592180
Lorenzo, Natalia; Mendez, Irene; Taibo, Mikel; Martinis, Gianfranco; Badia, Sara; Reyes, Guillermo; Aguilar, Rio
2018-01-01
Background Atrial fibrillation frequently affects patients with valvular heart disease. Ablation of atrial fibrillation during valvular surgery is an alternative for restoring sinus rhythm. Objectives This study aimed to evaluate mid-term results of successful atrial fibrillation surgical ablation during valvular heart disease surgery, to explore left atrium post-ablation mechanics and to identify predictors of recurrence. Methods Fifty-three consecutive candidates were included. Eligibility criteria for ablation included persistent atrial fibrillation <10 years and left atrium diameter < 6.0 cm. Three months after surgery, echocardiogram, 24-hour Holter monitoring and electrocardiograms were performed in all candidates who maintained sinus rhythm (44 patients). Echo-study included left atrial deformation parameters (strain and strain rate), using 2-dimensional speckle-tracking echocardiography. Simultaneously, 30 healthy individuals (controls) were analyzed with the same protocol for left atrial performance. Significance was considered with a P value of < 0.05. Results After a mean follow up of 17 ± 2 months, 13 new post-operative cases of recurrent atrial fibrillation were identified. A total of 1,245 left atrial segments were analysed. Left atrium was severely dilated in the post-surgery group and, mechanical properties of left atrium did not recover after surgery when compared with normal values. Left atrial volume (≥ 64 mL/m2) was the only independent predictor of atrial fibrillation recurrence (p = 0.03). Conclusions Left atrial volume was larger in patients with atrial fibrillation recurrence and emerges as the main predictor of recurrences, thereby improving the selection of candidates for this therapy; however, no differences were found regarding myocardial deformation parameters. Despite electrical maintenance of sinus rhythm, left atrium mechanics did not recover after atrial fibrillation ablation performed during valvular heart disease surgery. PMID:29561964
Pediatric echocardiography: new developments and applications.
Ge, Shuping
2013-04-01
In this Special Issue of the Journal, 6 review articles that represent the new developments and applications of echocardiography for diagnosis and assessment of congenital heart disease from fetus to adult are included. The goal is to provide an updated review of the evidence for the current and potential use of some of the new methodologies, i.e. fetal echocardiography, tissue Doppler imaging, strain imaging by speckle tracking imaging, ventricular synchrony, quantification using real time three-dimensional (3D) echocardiography, and 3D echocardiography for adults with congenital heart disease. We hope this effort will provide an impetus for more investigation and ultimately clinical application of these new methodologies to improve the care of those with congenital and acquired heart diseases in the pediatric population and beyond. © 2013, Wiley Periodicals, Inc.
Improvements In A Laser-Speckle Surface-Strain Gauge
NASA Technical Reports Server (NTRS)
Lant, Christian T.
1996-01-01
Compact optical subsystem incorporates several improvements over optical subsystems of previous versions of laser-speckle surface-strain gauge: faster acquisition of data, faster response to transients, reduced size and weight, lower cost, and less complexity. Principle of operation described previously in "Laser System Measures Two-Dimensional Strain" (LEW-15046), and "Two-Dimensional Laser-Speckle Surface-Strain Gauge" (LEW-15337).
Techniques of noninvasive optical tomographic imaging
NASA Astrophysics Data System (ADS)
Rosen, Joseph; Abookasis, David; Gokhler, Mark
2006-01-01
Recently invented methods of optical tomographic imaging through scattering and absorbing media are presented. In one method, the three-dimensional structure of an object hidden between two biological tissues is recovered from many noisy speckle pictures obtained on the output of a multi-channeled optical imaging system. Objects are recovered from many speckled images observed by a digital camera through two stereoscopic microlens arrays. Each microlens in each array generates a speckle image of the object buried between the layers. In the computer each image is Fourier transformed jointly with an image of the speckled point-like source captured under the same conditions. A set of the squared magnitudes of the Fourier-transformed pictures is accumulated to form a single average picture. This final picture is again Fourier transformed, resulting in the three-dimensional reconstruction of the hidden object. In the other method, the effect of spatial longitudinal coherence is used for imaging through an absorbing layer with different thickness, or different index of refraction, along the layer. The technique is based on synthesis of multiple peak spatial degree of coherence. This degree of coherence enables us to scan simultaneously different sample points on different altitudes, and thus decreases the acquisition time. The same multi peak degree of coherence is also used for imaging through the absorbing layer. Our entire experiments are performed with a quasi-monochromatic light source. Therefore problems of dispersion and inhomogeneous absorption are avoided.
Flux or speed? Examining speckle contrast imaging of vascular flows
Kazmi, S. M. Shams; Faraji, Ehssan; Davis, Mitchell A.; Huang, Yu-Yen; Zhang, Xiaojing J.; Dunn, Andrew K.
2015-01-01
Speckle contrast imaging enables rapid mapping of relative blood flow distributions using camera detection of back-scattered laser light. However, speckle derived flow measures deviate from direct measurements of erythrocyte speeds by 47 ± 15% (n = 13 mice) in vessels of various calibers. Alternatively, deviations with estimates of volumetric flux are on average 91 ± 43%. We highlight and attempt to alleviate this discrepancy by accounting for the effects of multiple dynamic scattering with speckle imaging of microfluidic channels of varying sizes and then with red blood cell (RBC) tracking correlated speckle imaging of vascular flows in the cerebral cortex. By revisiting the governing dynamic light scattering models, we test the ability to predict the degree of multiple dynamic scattering across vessels in order to correct for the observed discrepancies between relative RBC speeds and multi-exposure speckle imaging estimates of inverse correlation times. The analysis reveals that traditional speckle contrast imagery of vascular flows is neither a measure of volumetric flux nor particle speed, but rather the product of speed and vessel diameter. The corrected speckle estimates of the relative RBC speeds have an average 10 ± 3% deviation in vivo with those obtained from RBC tracking. PMID:26203384
Flux or speed? Examining speckle contrast imaging of vascular flows.
Kazmi, S M Shams; Faraji, Ehssan; Davis, Mitchell A; Huang, Yu-Yen; Zhang, Xiaojing J; Dunn, Andrew K
2015-07-01
Speckle contrast imaging enables rapid mapping of relative blood flow distributions using camera detection of back-scattered laser light. However, speckle derived flow measures deviate from direct measurements of erythrocyte speeds by 47 ± 15% (n = 13 mice) in vessels of various calibers. Alternatively, deviations with estimates of volumetric flux are on average 91 ± 43%. We highlight and attempt to alleviate this discrepancy by accounting for the effects of multiple dynamic scattering with speckle imaging of microfluidic channels of varying sizes and then with red blood cell (RBC) tracking correlated speckle imaging of vascular flows in the cerebral cortex. By revisiting the governing dynamic light scattering models, we test the ability to predict the degree of multiple dynamic scattering across vessels in order to correct for the observed discrepancies between relative RBC speeds and multi-exposure speckle imaging estimates of inverse correlation times. The analysis reveals that traditional speckle contrast imagery of vascular flows is neither a measure of volumetric flux nor particle speed, but rather the product of speed and vessel diameter. The corrected speckle estimates of the relative RBC speeds have an average 10 ± 3% deviation in vivo with those obtained from RBC tracking.
Motion-compensated speckle tracking via particle filtering
NASA Astrophysics Data System (ADS)
Liu, Lixin; Yagi, Shin-ichi; Bian, Hongyu
2015-07-01
Recently, an improved motion compensation method that uses the sum of absolute differences (SAD) has been applied to frame persistence utilized in conventional ultrasonic imaging because of its high accuracy and relative simplicity in implementation. However, high time consumption is still a significant drawback of this space-domain method. To seek for a more accelerated motion compensation method and verify if it is possible to eliminate conventional traversal correlation, motion-compensated speckle tracking between two temporally adjacent B-mode frames based on particle filtering is discussed. The optimal initial density of particles, the least number of iterations, and the optimal transition radius of the second iteration are analyzed from simulation results for the sake of evaluating the proposed method quantitatively. The speckle tracking results obtained using the optimized parameters indicate that the proposed method is capable of tracking the micromotion of speckle throughout the region of interest (ROI) that is superposed with global motion. The computational cost of the proposed method is reduced by 25% compared with that of the previous algorithm and further improvement is necessary.
Syeda, Bonni; Höfer, Peter; Pichler, Philipp; Vertesich, Markus; Bergler-Klein, Jutta; Roedler, Susanne; Mahr, Stephane; Goliasch, Georg; Zuckermann, Andreas; Binder, Thomas
2011-07-01
Longitudinal strain determined by speckle tracking is a sensitive parameter to detect systolic left ventricular dysfunction. In this study, we assessed regional and global longitudinal strain values in long-term heart transplants and compared deformation indices with ejection fraction as determined by transthoracic echocardiography (TTE) and multislice computed tomographic coronary angiography (MSCTA). TTE and MSCTA were prospectively performed in 31 transplant patients (10.6 years post-transplantation) and in 42 control subjects. Grey-scale apical views were recorded for speckle tracking (EchoPAC 7.0, GE) of the 16 segments of the left ventricle. The presence of coronary artery disease (CAD) was assessed by MSCTA. Strain analysis was performed in 1168 segments [496 in transplant patients (42.5%), 672 in control subjects (57.7%)]. Global longitudinal peak systolic strain was significantly lower in the transplant recipients than in the healthy population (-13.9 ± 4.2 vs. -17.4 ± 5.8%, P< 0.01). This was still the case after exclusion of the nine transplant patients with CAD (-14.1 ± 4.4 vs. -17.4 ± 5.8%, P=0.03). Transplant patients exhibited significantly lower regional strain values in 9 of the 16 segments. Left ventricular ejection fraction (%) (MSCTA/Simpsons method) was 60.7 ± 10.1%/60.2 ± 6.7% in transplant recipients vs. 64.7 ± 6.4%/63.0 ± 6.2% in the healthy population, P=ns. Even though 'healthy' heart transplants without CAD exhibit normal ejection fraction, deformation indices are reduced in this population when compared with control subjects. Our findings suggests that strain analysis is more sensitive than assessment of ejection fraction for the detection of abnormalities of systolic function.
Schouver, Elie-Dan; Moceri, Pamela; Doyen, Denis; Tieulie, Nathalie; Queyrel, Viviane; Baudouy, Delphine; Cerboni, Pierre; Gibelin, Pierre; Leroy, Sylvie; Fuzibet, Jean-Gabriel; Ferrari, Emile
2017-01-15
Cardiac sarcoidosis (CS) is associated with high morbidity and sudden death. The absence of specific symptoms and lack of diagnostic gold standard technique is challenging. New imaging methods could improve the diagnosis of CS. The aim of our study was to assess the role of left ventricular (LV) longitudinal and circumferential strain as estimated by 2D speckle-tracking imaging in patients with diagnosed sarcoidosis without cardiac involvement according to the current guidelines. We investigated the prevalence of LV strain impairment in this population and assessed its relationship with clinical outcomes, composite of mortality, heart failure, arrhythmia and/or secondarily development of CS and cardiac device implantation. We performed a prospective case-control longitudinal study including 35 patients with diagnosed sarcoidosis and normal cardiac function as assessed by standard transthoracic echocardiography and 35 healthy age- and gender-matched controls. All patients underwent a comprehensive echocardiographic study. Mean age of patients was 47.9±14.8years old (22 women). Compared with controls, global LV longitudinal strain (LV GLS) was reduced in sarcoidosis patients: (-17.2±3.1 vs -21.3±1.5%, p<0.0001). Circumferential LV strain was preserved in patients compared to controls (-19.9±-4.3% vs -21.3±1.5%, p=0.12). Impaired LV GLS was significantly associated with clinical outcomes (HR 1.56; [1.16-2.11], p<0.01) on univariate analysis. Speckle-tracking echocardiography revealed decreased longitudinal LV strain in sarcoidosis patients that was associated with outcomes. LV GLS may represent an early marker of myocardial involvement in sarcoidosis patients that needs to be studied further. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Bernard, Yvette; Morel, Mathilde; Descotes-Genon, Vincent; Jehl, Jerome; Meneveau, Nicolas; Schiele, Francois
2014-04-01
Right ventricular (RV) function is a major prognostic factor in patients (pts) with operated tetralogy of Fallot (TOF). We compared the results of RV speckle tracking (two-dimensional [2D] strain) with those of magnetic resonance imaging (MRI) in this setting. At transthoracic echocardiogram (echo), RV fractional area change (RVFAC), tricuspid annular plane systolic excursion (TAPSE), velocity of S-wave at tricuspid annulus with tissue Doppler, and 2D strain (longitudinal maximal systolic strain) were recorded. Their results were compared to RV indexed end-diastolic volume (EDV), indexed end-systolic volume (ESV), and RV ejection fraction (EF) at MRI. Twenty-two pts (16 M) aged 11-62 years (mean 23.2 ± 10.8) were included. Parameters of RV systolic function were as follows: RVFAC = 40 ± 10%, TAPSE = 18 ± 4 mm, S-wave = 10 ± 0.2 cm/sec, and RV EF at MRI = 43 ± 11%. Global RV systolic strain was -15.5 ± 4.2%, free wall strain was -15.1 ± 6.3%, and septal strain was -15.8 ± 3.8% on average for the whole group. Echo indexed RV end-diastolic area correlated with EDV at MRI (r = 0.73), as well as echo indexed RV end-systolic area and ESV at MRI (r = 0.71). Global RV 2D strain correlated well with RV EF at MRI: r = 0.68; P < 0.05, and with ESV at MRI: r = 0.63. Feasibility, intra- and inter-observer reproducibility of 2D strain were adequate. Speckle tracking is a promising method to estimate RV systolic function in pts operated on for TOF. © 2013, Wiley Periodicals, Inc.
Yoon, Ji Hyun; Cho, In-Jeong; Sung, Ji Min; Lee, Jinyong; Ryoo, Hojin; Shim, Chi Young; Hong, Geu-Ru; Chung, Namsik
2016-01-01
Background Carotid intima media thickness (CIMT) and the presence of carotid plaque have been used for risk stratification of cardiovascular disease (CVD). To date, however, the association between multi-directional functional properties of carotid artery and CVD has not been fully elucidated. We sought to explore the multi-directional mechanics of the carotid artery in relation to cardiovascular risk. Methods Four hundred one patients who underwent carotid ultrasound were enrolled between January 2010 and April 2013. A high risk of CVD was defined as more than 20% of 10-year risk based on the Framingham risk score. Using a speckle-tracking technique, the longitudinal and radial movements were analyzed in the B-mode images. Peak longitudinal and radial displacements, strain and strain rate were also measured. Beta stiffness and elastic modulus index were calculated from the radial measurements. Results Of the overall sample, 13% (52) of patients comprised the high-risk group. In multivariate logistic regression, CIMT and elastic modulus index were independently associated with a high-risk of CVD {odds ratio (OR): 1.810 [95% confidence interval (CI) 1.249–2.622] and OR: 1.767 (95% CI: 1.177–2.652); p = 0.002, 0.006, respectively}. The combination of CIMT and elastic modulus index correlated with a high-risk of CVD more so than CIMT alone. Conclusion The elastic modulus index of the carotid artery might serve as a novel surrogate marker of high-risk CVD. Measurement of the multi-directional mechanics of the carotid artery using the speckle tracking technique has potential for providing further information over conventional B-mode ultrasound for stratification of CVD risk. PMID:27721952
Shen, Jiaqi; Zhou, Qiao; Liu, Yue; Luo, Runlan; Tan, Bijun; Li, Guangsen
2016-08-23
Iron-deficiency anemia (IDA) is a global health problem and a common medical condition that can be seen in everyday clinical practice. And two-dimensional speckle tracking echocardiography (2D-STE) has been reported very useful in evaluating left atrial (LA) function, as well as left ventricular (LV) function. The aim of our study is to evaluate the LA function in patients with IDA by 2D-STE. 65 patients with IDA were selected. This group of patients was then divided into two groups according to the degree of hemoglobin: group B (Hb > 90 g/L) and group C (Hb60 ~ 90 g/L). Another 30 healthy people were also selected as control group A. Conventional echocardiography parameters, such as left atrial diameter (LAD), peak E and A of mitralis (E, A), E/A, end-diastolic thickness of ventricular septum (IVST d), end-diastolic thickness of LV posterior wall (PWTd) and left ventricular end-diastolic dimension (LVDd) were obtained from these three groups. Left atrial minimum volume (LAVmin), left atrial pre-atrial contraction volume (LAVp) and left atrial maximum volume (LAVmax) were measured by Simpson's rule, whereas left atrial active ejection fraction (LAAEF) and left atrial passive ejection fraction (LAPEF) were obtained from calculation. Two-dimensional images were acquired from apical four-chamber view and two-chamber view to store images for offline analysis. The global peak atrial longitudinal strain and strain rate of systolic LV (GLSs, GLSRs) as well as early and late diastolic LV strain rate (GLSRe, GLSRa) curves of LA were acquired in each LA segment from basal segment to top segment of LA by 2D-STE. Compared with group A, there were no differences between group B and group A (all P > 0.05). The LAAEF and GLSRa were significantly higher in group C compared with those of group A and group B (all P < 0.01). The LAPEF, GLSs, GLSRs and GLSRe were significantly lower in group C compared with those of group A and group B (all P < 0.01). 2D-STE could evaluate the LA function in patients with IDA.
Larsson, Matilda; Heyde, Brecht; Kremer, Florence; Brodin, Lars-Åke; D'hooge, Jan
2015-02-01
Ultrasound speckle tracking for carotid strain assessment has in the past decade gained interest in studies of arterial stiffness and cardiovascular diseases. The aim of this study was to validate and directly contrast carotid strain assessment by speckle tracking applied on clinical and high-frequency ultrasound images in vitro. Four polyvinyl alcohol phantoms mimicking the carotid artery were constructed with different mechanical properties and connected to a pump generating carotid flow profiles. Gray-scale ultrasound long- and short-axis images of the phantoms were obtained using a standard clinical ultrasound system, Vivid 7 (GE Healthcare, Horten, Norway) and a high-frequency ultrasound system, Vevo 2100 (FUJIFILM, VisualSonics, Toronto, Canada) with linear-array transducers (12L/MS250). Radial, longitudinal and circumferential strains were estimated using an in-house speckle tracking algorithm and compared with reference strain acquired by sonomicrometry. Overall, the estimated strain corresponded well with the reference strain. The correlation between estimated peak strain in clinical ultrasound images and reference strain was 0.91 (p<0.001) for radial strain, 0.73 (p<0.001) for longitudinal strain and 0.90 (p<0.001) for circumferential strain and for high-frequency ultrasound images 0.95 (p<0.001) for radial strain, 0.93 (p<0.001) for longitudinal strain and 0.90 (p<0.001) for circumferential strain. A significant larger bias and root mean square error was found for circumferential strain estimation on clinical ultrasound images compared to high frequency ultrasound images, but no significant difference in bias and root mean square error was found for radial and longitudinal strain when comparing estimation on clinical and high-frequency ultrasound images. The agreement between sonomicrometry and speckle tracking demonstrates that carotid strain assessment by ultrasound speckle tracking is feasible. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Advances in three-dimensional integral imaging: sensing, display, and applications [Invited].
Xiao, Xiao; Javidi, Bahram; Martinez-Corral, Manuel; Stern, Adrian
2013-02-01
Three-dimensional (3D) sensing and imaging technologies have been extensively researched for many applications in the fields of entertainment, medicine, robotics, manufacturing, industrial inspection, security, surveillance, and defense due to their diverse and significant benefits. Integral imaging is a passive multiperspective imaging technique, which records multiple two-dimensional images of a scene from different perspectives. Unlike holography, it can capture a scene such as outdoor events with incoherent or ambient light. Integral imaging can display a true 3D color image with full parallax and continuous viewing angles by incoherent light; thus it does not suffer from speckle degradation. Because of its unique properties, integral imaging has been revived over the past decade or so as a promising approach for massive 3D commercialization. A series of key articles on this topic have appeared in the OSA journals, including Applied Optics. Thus, it is fitting that this Commemorative Review presents an overview of literature on physical principles and applications of integral imaging. Several data capture configurations, reconstruction, and display methods are overviewed. In addition, applications including 3D underwater imaging, 3D imaging in photon-starved environments, 3D tracking of occluded objects, 3D optical microscopy, and 3D polarimetric imaging are reviewed.
Zhu, Pei-hua; Huang, Jing-yuan; Ye, Meng; Zheng, Zhe-lan
2014-09-01
To evaluate the left ventricular twist characteristics in patients with type 2 diabetes by using two-dimensional speckle tracking imaging (STI). Ninety-three patients with type 2 diabetes admitted in Zhejiang Hospital from May 2012 to September 2013 were enrolled. According to left ventricular ejection fraction (LVEF), patients were divided into two groups: normal left ventricular systolic function group (group A, LVEF≥0.50, n=46) and abnormal left ventricular systolic function group (group B, LVEF <0.50, n=47). Forty-six healthy subjects were selected as normal controls. STI was applied to quantitatively analyze the left ventricular twist. Correlation of the peak of left ventricular twist angle (Peaktw), aortic valve closure time twist angle (AVCtw), and mitral valve opening time twist angle (MVOtw) with LVEF, Tei index, E/A, and E/e was evaluated. Consistency check for STI was conducted to assess its stability and reliability. The Peaktw, AVCtw, and MVOtw in group A were significantly elevated than those in normal controls (P<0.05). The Peaktw, AVCtw, and MVOtw in group B was lower than those in normal controls and group A (P<0.05). In diabetic patients, the Peaktw, AVCtw, MVOtw were positively correlated with LVEF (r=0.968, 0.966, 0.938;P<0.05) and E/A (r=0.798, 0.790, 0.788; P<0.05), and were negatively correlated with Tei index (r=-0.834, -0.811, -0.797; P<0.05) and E/e (r=-0.823, -0.805, -0.771; P<0.05). The agreement between measurers and within measurers of Peaktw was satisfactory (between measurers: R=0.957, bias=-0.1, 95% consistency limit=-2.8-2.7; within measurer: R=0.964, bias=-0.2, 95% consistency limits=-2.7-2.2). STI can be used for early recognition of abnormal changes of cardiac function in type 2 diabetic mellitus patients, with high stability and reliability.
Kossaify, Antoine; Grollier, Gilles
2014-01-01
Echocardiography accounts for nearly half of all cardiac imaging techniques. It is a widely available and adaptable tool, as well as being a cost-effective and mainly a non-invasive test. In addition, echocardiography provides extensive clinical data, which is related to the presence or advent of different modalities (tissue Doppler imaging, speckle tracking imaging, three-dimensional mode, contrast echo, etc.), different approaches (transesophageal, intravascular, etc.), and different applications (ie, heart failure/resynchronization studies, ischemia/stress echo, etc.). In view of this, it is essential to conform to criteria of appropriate use and to keep standards of competence. In this study, we sought to review and discuss clinical practice of echocardiography in light of the criteria of appropriate clinical use, also we present an insight into echocardiographic technical competence and quality improvement project. PMID:24516342
Ancona, Roberta; Comenale Pinto, Salvatore; Caso, Pio; D'Andrea, Antonello; Di Salvo, Giovanni; Arenga, Fortunato; Coppola, Maria Gabriella; Sellitto, Vincenzo; Macrino, Maria; Calabrò, Raffaele
2014-01-01
Although often referred to as "the forgotten chamber", compared with left ventricle (LV), especially in the past years, the left atrium (LA) plays a critical role in the clinical expression and prognosis of patients with heart and cerebrovascular disease, as demonstrated by several studies. Echocardiographers initially focused on early detection of atrial geometrical abnormalities through monodimensional atrial diameter quantification and then bidimensional (2D) areas and volume estimation. Now, together with conventional echocardiographic parameters, new echocardiographic techniques, such as strain Doppler, 2D speckle tracking and three-dimensional (3D) echocardiography, allow assessing early LA dysfunction and they all play a fundamental role to detect early functional remodelling before anatomical alterations occur. LA dysfunction and its important prognostic implications may be detected sooner by LA strain than by volumetric measurements.
Laser speckle tracking for monitoring and analysis of retinal photocoagulation
NASA Astrophysics Data System (ADS)
Seifert, Eric; Bliedtner, Katharina; Brinkmann, Ralf
2014-02-01
Laser coagulation of the retina is an established treatment for several retinal diseases. The absorbed laser energy and thus the induced thermal damage varies with the transmittance and scattering properties of the anterior eye media and with the pigmentation of the fundus. The temperature plays the most important role in the coagulation process. An established approach to measure a mean retinal temperature rise is optoacoustics, however it provides limited information on the coagulation. Phase sensitive OCT potentially offers a three dimensional temporally resolved temperature distribution but is very sensitive to slightest movements which are clinically hard to avoid. We develop an optical technique able to monitor and quantify thermally and coagulation induced tissue movements (expansions and contractions) and changes in the tissue structure by dynamic laser speckle analysis (LSA) offering a 2D map of the affected area. A frequency doubled Nd:YAG laser (532nm) is used for photocoagulation. Enucleated porcine eyes are used as targets. The spot is 100μm. A Helium Neon laser (HeNe) is used for illumination. The backscattered light of a HeNe is captured with a camera and the speckle pattern is analyzed. A Q-switched Nd:YLF laser is used for simultaneous temperature measurements with the optoacoustic approach. Radial tissue movements in the micrometer regime have been observed. The signals evaluation by optical flow algorithms and generalized differences tuned out to be able to distinguish between regions with and without immediate cell damage. Both approaches have shown a sensitivity of 93% and a specificity above 99% at their optimal threshold.
Two-Dimensional Laser-Speckle Surface-Strain Gauge
NASA Technical Reports Server (NTRS)
Barranger, John P.; Lant, Christian
1992-01-01
Extension of Yamaguchi's laser-speckle surface-strain-gauge method yields data on two-dimensional surface strains in times as short as fractions of second. Laser beams probe rough spot on surface of specimen before and after processing. Changes in speckle pattern of laser light reflected from spot indicative of changes in surface strains during processing. Used to monitor strains and changes in strains induced by hot-forming and subsequent cooling of steel.
NASA Astrophysics Data System (ADS)
Yin, L.; Albright, B. J.; Rose, H. A.; Bowers, K. J.; Bergen, B.; Montgomery, D. S.; Kline, J. L.; Fernández, J. C.
2009-11-01
A suite of three-dimensional (3D) VPIC [K. J. Bowers et al., Phys. Plasmas 15, 055703 (2008)] particle-in-cell simulations of backward stimulated Raman scattering (SRS) in inertial confinement fusion hohlraum plasma has been performed on the heterogeneous multicore supercomputer, Roadrunner, presently the world's most powerful supercomputer. These calculations reveal the complex nonlinear behavior of SRS and point to a new era of "at scale" 3D modeling of SRS in solitary and multiple laser speckles. The physics governing nonlinear saturation of SRS in a laser speckle in 3D is consistent with that of prior two-dimensional (2D) studies [L. Yin et al., Phys. Rev. Lett. 99, 265004 (2007)], but with important differences arising from enhanced diffraction and side loss in 3D compared with 2D. In addition to wave front bowing of electron plasma waves (EPWs) due to trapped electron nonlinear frequency shift and amplitude-dependent damping, we find for the first time that EPW self-focusing, which evolved from trapped particle modulational instability [H. A. Rose and L. Yin, Phys. Plasmas 15, 042311 (2008)], also exhibits loss of angular coherence by formation of a filament necklace, a process not available in 2D. These processes in 2D and 3D increase the side-loss rate of trapped electrons, increase wave damping, decrease source coherence for backscattered light, and fundamentally limit how much backscatter can occur from a laser speckle. For both SRS onset and saturation, the nonlinear trapping induced physics is not captured in linear gain modeling of SRS. A simple metric is described for using single-speckle reflectivities obtained from VPIC simulations to infer the total reflectivity from the population of laser speckles of amplitude sufficient for significant trapping-induced nonlinearity to arise.
Progress in speckle-shift strain measurement
NASA Technical Reports Server (NTRS)
Lant, Christian T.; Barranger, John P.; Oberle, Lawrence G.; Greer, Lawrence C., III
1991-01-01
The Instrumentation and Control Technology Division of the Lewis Research Center has been developing an in-house capability to make one dimensional and two dimensional optical strain measurements on high temperature test specimens. The measurements are based on a two-beam speckle-shift technique. The development of composite materials for use in high temperature applications is generating interest in using the speckle-shift technique to measure strains on small diameter fibers and wires of various compositions. The results of preliminary speckle correlation tests on wire and fiber specimens are covered, and the advanced system currently under development is described.
Balli, Sevket; Yucel, Ilker Kemal; Kibar, Ayse Esin; Ece, Ibrahim; Dalkiran, Eylem Sen; Candan, Sukru
2016-11-01
Extra genetic material in patients with Down syndrome (DS) may affect the function of any organ system. We evaluated cardiac functions using conventional tissue Doppler and two-dimensional speckle tracking echocardiography in patients with DS in the absence of congenital and acquired heart disease in patients. A total of 115 patients with DS between 6 and 13 years of age with clinically and anatomically normal heart and 55 healthy children were included in this cross-sectional study. DS was diagnosed by a karyotype test. Patients with mosaic type were not included in this study. Systolic and diastolic functions were evaluated by echocardiography. Pulsed waved Doppler transmitral early/late inflow velocity (E/A), tissue Doppler mitral annular early/late diastolic peak velocity (Ea/Aa), transtricuspid E/A and tricuspid valve annulus Ea/Aa, pulmonary venous Doppler systolic/diastolic (S/D) wave ratio were lower in patients with Down syndrome than in the control group (P=0.04, P=0.001, P<0.05, P<0.001, P<0.001, respectively). Mitral and tricuspid annular Ea were lower in patients with DS (P<0.001). The right and left ventricular myocardial performance indexes were higher in patients with DS than in the controls (P<0.01). They had significantly higher left ventricular mass, ejection fraction, the mitral annular plane systolic excursion values. However, the Down syndrome group compared with the controls had a lower strain values examined by two-dimensional longitudinal speckle-tracking strain echocardiography. These findings suggest conventional tissue Doppler and two-dimensional longitudinal speckletracking strain echocardiography were useful methods of investigating ventricular function and identifying a higher incidence of biventricular dysfunction in patients with Down syndrome compared with the healthy controls.
Theoretical investigations on dual-beam illumination electronic speckle pattern interferometry
NASA Astrophysics Data System (ADS)
Goudemand, Nicolas
2006-07-01
Contrary to what is found in most of the existing scientific literature, where a specific frame is developed, the theory of speckle interferometry is (conveniently) presented here as a particular case of the more general theory of holographic interferometry. In addition to the intellectual benefit of dealing with a single unified theory, this brings about many advantages when it comes to discuss fundamental topics such as the three-dimensional evolution of the complex amplitude of the diffuse optical wavefronts, the degree of approximation of the leading formulas, the loss of fringe contrast, the decorrelation effects, the real influence of the terms generally neglected in out-of-focus regions. In the same way, the statistical properties of the speckle fields, usually treated as a separate subject matter, are also integrated in the theory, thus providing a comprehensive knowledge of the qualitative features of speckle interferometry methods, otherwise difficult to understand.
Castel, Anne-Laure; Menet, Aymeric; Ennezat, Pierre-Vladimir; Delelis, François; Le Goffic, Caroline; Binda, Camille; Guerbaai, Raphaëlle-Ashley; Levy, Franck; Graux, Pierre; Tribouilloy, Christophe; Maréchaux, Sylvestre
2016-01-01
Speckle tracking can be used to measure left ventricular global longitudinal strain (GLS). To study the effect of speckle tracking software product upgrades on GLS values and intervendor consistency. Subjects (patients or healthy volunteers) underwent systematic echocardiography with equipment from Philips and GE, without a change in their position. Off-line post-processing for GLS assessment was performed with the former and most recent upgrades from these two vendors (Philips QLAB 9.0 and 10.2; GE EchoPAC 12.1 and 13.1.1). GLS was obtained in three myocardial layers with EchoPAC 13.1.1. Intersoftware and intervendor consistency was assessed. Interobserver variability was tested in a subset of patients. Among 73 subjects (65 patients and 8 healthy volunteers), absolute values of GLS were higher with QLAB 10.2 compared with 9.0 (intraclass correlation coefficient [ICC]: 0.88; bias: 2.2%). Agreement between EchoPAC 13.1.1 and 12.1 varied by myocardial layer (13.1.1 only): midwall (ICC: 0.95; bias: -1.1%), endocardium (ICC: 0.93; bias: 1.6%) and epicardial (ICC: 0.80; bias: -3.3%). Although GLS was comparable for QLAB 9.0 versus EchoPAC 12.1 (ICC: 0.95; bias: 0.5%), the agreement was lower between QLAB 10.2 and EchoPAC 13.1.1 endocardial (ICC: 0.91; bias: 1.1%), midwall (ICC: 0.73; bias: 3.9%) and epicardial (ICC: 0.54; bias: 6.0%). Interobserver variability of all software products in a subset of 20 patients was excellent (ICC: 0.97-0.99; bias: -0.8 to 1.0%). Upgrades of speckle tracking software may be associated with significant changes in GLS values, which could affect intersoftware and intervendor consistency. This finding has important clinical implications for the longitudinal follow-up of patients with speckle tracking echocardiography. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
High-Frame-Rate Speckle-Tracking Echocardiography.
Joos, Philippe; Poree, Jonathan; Liebgott, Herve; Vray, Didier; Baudet, Mathilde; Faurie, Julia; Tournoux, Francois; Cloutier, Guy; Nicolas, Barbara; Garcia, Damien; Baudet, Mathilde; Tournoux, Francois; Joos, Philippe; Poree, Jonathan; Cloutier, Guy; Liebgott, Herve; Faurie, Julia; Vray, Didier; Nicolas, Barbara; Garcia, Damien
2018-05-01
Conventional echocardiography is the leading modality for noninvasive cardiac imaging. It has been recently illustrated that high-frame-rate echocardiography using diverging waves could improve cardiac assessment. The spatial resolution and contrast associated with this method are commonly improved by coherent compounding of steered beams. However, owing to fast tissue velocities in the myocardium, the summation process of successive diverging waves can lead to destructive interferences if motion compensation (MoCo) is not considered. Coherent compounding methods based on MoCo have demonstrated their potential to provide high-contrast B-mode cardiac images. Ultrafast speckle-tracking echocardiography (STE) based on common speckle-tracking algorithms could substantially benefit from this original approach. In this paper, we applied STE on high-frame-rate B-mode images obtained with a specific MoCo technique to quantify the 2-D motion and tissue velocities of the left ventricle. The method was first validated in vitro and then evaluated in vivo in the four-chamber view of 10 volunteers. High-contrast high-resolution B-mode images were constructed at 500 frames/s. The sequences were generated with a Verasonics scanner and a 2.5-MHz phased array. The 2-D motion was estimated with standard cross correlation combined with three different subpixel adjustment techniques. The estimated in vitro velocity vectors derived from STE were consistent with the expected values, with normalized errors ranging from 4% to 12% in the radial direction and from 10% to 20% in the cross-range direction. Global longitudinal strain of the left ventricle was also obtained from STE in 10 subjects and compared to the results provided by a clinical scanner: group means were not statistically different ( value = 0.33). The in vitro and in vivo results showed that MoCo enables preservation of the myocardial speckles and in turn allows high-frame-rate STE.
DOE Office of Scientific and Technical Information (OSTI.GOV)
O’Shea, T; Bamber, J; Harris, E
Purpose: For ultrasound speckle tracking there is some evidence that the envelope-detected signal (the main step in B-mode image formation) may be more accurate than raw ultrasound data for tracking larger inter-frame tissue motion. This study investigates the accuracy of raw radio-frequency (RF) versus non-logarithmic compressed envelope-detected (B-mode) data for ultrasound speckle tracking in the context of image-guided radiation therapy. Methods: Transperineal ultrasound RF data was acquired (with a 7.5 MHz linear transducer operating at a 12 Hz frame rate) from a speckle phantom moving with realistic intra-fraction prostate motion derived from a commercial tracking system. A normalised cross-correlation templatemore » matching algorithm was used to track speckle motion at the focus using (i) the RF signal and (ii) the B-mode signal. A range of imaging rates (0.5 to 12 Hz) were simulated by decimating the imaging sequences, therefore simulating larger to smaller inter-frame displacements. Motion estimation accuracy was quantified by comparison with known phantom motion. Results: The differences between RF and B-mode motion estimation accuracy (2D mean and 95% errors relative to ground truth displacements) were less than 0.01 mm for stable and persistent motion types and 0.2 mm for transient motion for imaging rates of 0.5 to 12 Hz. The mean correlation for all motion types and imaging rates was 0.851 and 0.845 for RF and B-mode data, respectively. Data type is expected to have most impact on axial (Superior-Inferior) motion estimation. Axial differences were <0.004 mm for stable and persistent motion and <0.3 mm for transient motion (axial mean errors were lowest for B-mode in all cases). Conclusions: Using the RF or B-mode signal for speckle motion estimation is comparable for translational prostate motion. B-mode image formation may involve other signal-processing steps which also influence motion estimation accuracy. A similar study for respiratory-induced motion would also be prudent. This work is support by Cancer Research UK Programme Grant C33589/A19727.« less
Wholefield displacement measurements using speckle image processing techniques for crash tests
NASA Astrophysics Data System (ADS)
Sriram, P.; Hanagud, S.; Ranson, W. F.
The digital correlation scheme of Peters et al. (1983) was extended to measure out-of-plane deformations, using a white light projection speckle technique. A simple ray optic theory and the digital correlation scheme are outlined. The technique was applied successfully to measure out-of-plane displacements of initially flat rotorcraft structures (an acrylic circular plate and a steel cantilever beam), using a low cost video camera and a desktop computer. The technique can be extended to measurements of three-dimensional deformations and dynamic deformations.
Speckle Tracking Imaging in Normal Stress Echocardiography.
Leitman, Marina; Tyomkin, Vladimir; Peleg, Eli; Zyssman, Izhak; Rosenblatt, Simcha; Sucher, Edgar; Gercenshtein, Vered; Vered, Zvi
2017-04-01
Exercise stress echocardiography is a widely used modality for the diagnosis and follow-up of patients with coronary artery disease. During the last decade, speckle tracking imaging has been used increasingly for accurate evaluation of cardiac function. This work aimed to assess speckle-tracking imaging parameters during nonischemic exercise stress echocardiography. During 2011 to 2014 we studied 46 patients without history of coronary artery disease, who completed exercise stress echocardiography protocol, had normal left ventricular function, a nonischemic response, and satisfactory image quality. These exams were analyzed with speckle-tracking imaging software at rest and at peak exercise. Peak strain and time-to-peak strain were measured at rest and after exercise. Clinical follow-up included a telephone contact 1 to 3 years after stress echo exam, confirming freedom from coronary events during this time. Global and regional peak strain increased following exercise. Time-to-peak global and regional strain and time-to-peak strain adjusted to the heart rate were significantly shorter in all segments after exercise. Rest-to-stress ratio of time-to-peak strain adjusted to the heart rate was 2.0 to 2.8. Global and regional peak strain rise during normal exercise echocardiography. Peak global and regional strain occur before or shortly after aortic valve closure at rest and after exercise, and the delay is more apparent at the basal segments. Time-to-peak strain normally shortens significantly during exercise; after adjustment to heart rate it shortens by a ratio of 2.0 to 2.8. These data may be useful for interpretation of future exercise stress speckle-tracking echocardiography studies. © 2016 by the American Institute of Ultrasound in Medicine.
Akram, M Nadeem; Tong, Zhaomin; Ouyang, Guangmin; Chen, Xuyuan; Kartashov, Vladimir
2010-06-10
We utilize spatial and angular diversity to achieve speckle reduction in laser illumination. Both free-space and imaging geometry configurations are considered. A fast two-dimensional scanning micromirror is employed to steer the laser beam. A simple experimental setup is built to demonstrate the application of our technique in a two-dimensional laser picture projection. Experimental results show that the speckle contrast factor can be reduced down to 5% within the integration time of the detector.
Zhang, Li; Zhang, Jing; Han, Wei; Gao, Jun; He, Lin; Yang, Yali; Yin, Ping; Xie, Mingxing; Ge, Shuping
2016-01-01
The specific aim of this study was to evaluate the feasibility, reproducibility and maturational changes of LV rotation, twist and torsion variables by real-time 3D speckle-tracking echocardiography (RT3DSTE) in children. A prospective study was conducted in 347 consecutive healthy subjects (181 males/156 females, mean age 7.12 ± 5.3 years, and range from birth to 18-years) using RT 3D echocardiography (3DE). The LV rotation, twist and torsion measurements were made off-line using TomTec software. Manual landmark selection and endocardial border editing were performed in 3 planes (apical "2"-, "4"-, and "3"- chamber views) and semi-automated tracking yielded LV rotation, twist and torsion measurements. LV rotation, twist and torsion analysis by RT 3DSTE were feasible in 307 out of 347 subjects (88.5%). There was no correlation between rotation or twist and age, height, weight, BSA or heart rate, respectively. However, there was statistically significant, but very modest correlation between LV torsion and age (R2 = 0.036, P< 0.001). The normal ranges were defined for rotation and twist in this cohort, and for torsion for each age group. The intra-observer and inter-observer variabilities for apical and basal rotation, twist and torsion ranged from 7.3% ± 3.8% to 12.3% ± 8.8% and from 8.8% ± 4.6% to 15.7% ± 10.1%, respectively. We conclude that analysis of LV rotation, twist and torsion by this new RT3D STE is feasible and reproducible in pediatric population. There is no maturational change in rotation and twist, but torsion decreases with age in this cohort. Further refinement is warranted to validate the utility of this new methodology in more sensitive and quantitative evaluation of congenital and acquired heart diseases in children.
Towards an Optimal Interest Point Detector for Measurements in Ultrasound Images
NASA Astrophysics Data System (ADS)
Zukal, Martin; Beneš, Radek; Číka, Petr; Říha, Kamil
2013-12-01
This paper focuses on the comparison of different interest point detectors and their utilization for measurements in ultrasound (US) images. Certain medical examinations are based on speckle tracking which strongly relies on features that can be reliably tracked frame to frame. Only significant features (interest points) resistant to noise and brightness changes within US images are suitable for accurate long-lasting tracking. We compare three interest point detectors - Harris-Laplace, Difference of Gaussian (DoG) and Fast Hessian - and identify the most suitable one for use in US images on the basis of an objective criterion. Repeatability rate is assumed to be an objective quality measure for comparison. We have measured repeatability in images corrupted by different types of noise (speckle noise, Gaussian noise) and for changes in brightness. The Harris-Laplace detector outperformed its competitors and seems to be a sound option when choosing a suitable interest point detector for US images. However, it has to be noted that Fast Hessian and DoG detectors achieved better results in terms of processing speed.
NASA Astrophysics Data System (ADS)
Piras, Paolo; Torromeo, Concetta; Re, Federica; Evangelista, Antonietta; Gabriele, Stefano; Esposito, Giuseppe; Nardinocchi, Paola; Teresi, Luciano; Madeo, Andrea; Chialastri, Claudia; Schiariti, Michele; Varano, Valerio; Uguccioni, Massimo; Puddu, Paolo E.
2016-10-01
The analysis of full Left Atrium (LA) deformation and whole LA deformational trajectory in time has been poorly investigated and, to the best of our knowledge, seldom discussed in patients with Hypertrophic Cardiomyopathy. Therefore, we considered 22 patients with Hypertrophic Cardiomyopathy (HCM) and 46 healthy subjects, investigated them by three-dimensional Speckle Tracking Echocardiography, and studied the derived landmark clouds via Geometric Morphometrics with Parallel Transport. Trajectory shape and trajectory size were different in Controls versus HCM and their classification powers had high AUC (Area Under the Receiving Operator Characteristic Curve) and accuracy. The two trajectories were much different at the transition between LA conduit and booster pump functions. Full shape and deformation analyses with trajectory analysis enabled a straightforward perception of pathophysiological consequences of HCM condition on LA functioning. It might be worthwhile to apply these techniques to look for novel pathophysiological approaches that may better define atrio-ventricular interaction.
Menting, Myrthe E; McGhie, Jackie S; Koopman, Laurens P; Vletter, Wim B; Helbing, Willem A; van den Bosch, Annemien E; Roos-Hesselink, Jolien W
2016-11-01
Evaluation of left ventricular (LV) myocardial deformation by speckle tracking echocardiography (STE) is useful for clinical and research purposes. However, strain measurements depend on the used software. Normative data for QLAB 10 (Philips) are scarce. Additionally, little is known about the influence of anthropometric factors. We aimed to establish normal adult STE-derived strain and strain rate values and to evaluate associations with anthropometrics. One hundred fifty-five healthy subjects aged 20 to 72 years (≥28 subjects per decile) were prospectively gathered and examined with electrocardiography and two-dimensional echocardiography. With STE, we assessed peak systolic LV global longitudinal strain (GLS), segmental longitudinal strain, and strain rate from the three standard apical views. We included 147 healthy subjects (age 44.6±13.7 years, 50% female, GLS -20.8±2.0%). Men had significantly lower GLS than women (-20.1±1.8% vs -21.5±2.0%, P<.001). GLS was significantly lower in subjects with age above 55 years (P=.029), higher blood pressure (P<.001), higher body surface area (BSA, P<.001), larger LV end-systolic and end-diastolic volumes (both P<.001), lower LV ejection fraction (P<.001), and some indices of diastolic function. After multivariable regression analysis, the correlation with systolic blood pressure, E-wave, and LV end-systolic volume remained significant. The systolic strain rates of most segments correlated with BSA. Our study resulted in normative LV GLS values assessed with QLAB 10. Male sex, higher BSA, and higher blood pressure negatively influence GLS. Therefore, these factors should be taken into account for strain interpretation in clinical practice. © 2016, Wiley Periodicals, Inc.
Ren, Min; Liu, Yujie; Zhao, Huiya; Dong, Shixia; Jiang, Zhonghui; Li, Keting; Tian, Jiawei
2016-10-01
Effects of ischemic postconditioning (IPostC) and adenosine triphosphate (ATP)-mediated pharmacologic postconditioning (ATP-PPostC) on cardiac function were evaluated by speckle tracking imaging (STI)-based echocardiography. A myocardial I/R model was induced in rabbits by reversible ligation of the left ventricular branch of coronary artery. Rabbits were randomized into three groups: ischemia and reperfusion (IR) (no further intervention), IPostC, and ATP-PPostC groups. Cardiac function was evaluated by conventional and STI-based echocardiography. Myocardial necrosis, apoptosis, and myocardial mRNAs of apoptosis-related proteins (Bcl-2 and Bax) were evaluated. Speckle tracking imaging (STI)-based echocardiography revealed that IPostC and ATP-PPostC were associated with better preserved global and regional cardiac function, as indicated by significantly increased GLSrsys, GLSrd, GLSsys, SrLsys, SrLd, and SLsys in both groups (all P<.5). Subsequent pathologic studies indicate that the percentage of necrotic myocardium and permillage of apoptotic cells were significantly lower in the IPostC and ATP-PPostC groups than in the IR group (all P<.05). Moreover, both IPostC and ATP-PPostC were associated with increased Bcl-2 mRNA levels and reduced Bax mRNA levels. IPostC and ATP-PPostC may exert cardioprotective functions by better preservation of cardiac function during the I/R process and at least partly via attenuation of myocardial apoptosis. © 2016 John Wiley & Sons Ltd.
Tracking quasi-stationary flow of weak fluorescent signals by adaptive multi-frame correlation.
Ji, L; Danuser, G
2005-12-01
We have developed a novel cross-correlation technique to probe quasi-stationary flow of fluorescent signals in live cells at a spatial resolution that is close to single particle tracking. By correlating image blocks between pairs of consecutive frames and integrating their correlation scores over multiple frame pairs, uncertainty in identifying a globally significant maximum in the correlation score function has been greatly reduced as compared with conventional correlation-based tracking using the signal of only two consecutive frames. This approach proves robust and very effective in analysing images with a weak, noise-perturbed signal contrast where texture characteristics cannot be matched between only a pair of frames. It can also be applied to images that lack prominent features that could be utilized for particle tracking or feature-based template matching. Furthermore, owing to the integration of correlation scores over multiple frames, the method can handle signals with substantial frame-to-frame intensity variation where conventional correlation-based tracking fails. We tested the performance of the method by tracking polymer flow in actin and microtubule cytoskeleton structures labelled at various fluorophore densities providing imagery with a broad range of signal modulation and noise. In applications to fluorescent speckle microscopy (FSM), where the fluorophore density is sufficiently low to reveal patterns of discrete fluorescent marks referred to as speckles, we combined the multi-frame correlation approach proposed above with particle tracking. This hybrid approach allowed us to follow single speckles robustly in areas of high speckle density and fast flow, where previously published FSM analysis methods were unsuccessful. Thus, we can now probe cytoskeleton polymer dynamics in living cells at an entirely new level of complexity and with unprecedented detail.
Speckle interferometry of asteroids
NASA Technical Reports Server (NTRS)
Drummond, Jack
1988-01-01
By studying the image two-dimensional power spectra or autocorrelations projected by an asteroid as it rotates, it is possible to locate its rotational pole and derive its three axes dimensions through speckle interferometry under certain assumptions of uniform, geometric scattering, and triaxial ellipsoid shape. However, in cases where images can be reconstructed, the need for making the assumptions is obviated. Furthermore, the ultimate goal for speckle interferometry of image reconstruction will lead to mapping albedo features (if they exist) as impact areas or geological units. The first glimpses of the surface of an asteroid were obtained from images of 4 Vesta reconstructed from speckle interferometric observations. These images reveal that Vesta is quite Moon-like in having large hemispheric-scale albedo features. All of its lightcurves can be produced from a simple model developed from the images. Although undoubtedly more intricate than the model, Vesta's lightcurves can be matched by a model with three dark and four bright spots. The dark areas so dominate one hemisphere that a lightcurve minimum occurs when the maximum cross-section area is visible. The triaxial ellipsoid shape derived for Vesta is not consistent with the notion that the asteroid has an equilibrium shape in spite of its having apparently been differentiated.
NASA Astrophysics Data System (ADS)
Tavakoli, Vahid; Stoddard, Marcus F.; Amini, Amir A.
2013-03-01
Quantitative motion analysis of echocardiographic images helps clinicians with the diagnosis and therapy of patients suffering from cardiac disease. Quantitative analysis is usually based on TDI (Tissue Doppler Imaging) or speckle tracking. These methods are based on two independent techniques - the Doppler Effect and image registration, respectively. In order to increase the accuracy of the speckle tracking technique and cope with the angle dependency of TDI, herein, a combined approach dubbed TDIOF (Tissue Doppler Imaging Optical Flow) is proposed. TDIOF is formulated based on the combination of B-mode and Doppler energy terms in an optical flow framework and minimized using algebraic equations. In this paper, we report on validations with simulated, physical cardiac phantom, and in-vivo patient data. It is shown that the additional Doppler term is able to increase the accuracy of speckle tracking, the basis for several commercially available echocardiography analysis techniques.
NASA Astrophysics Data System (ADS)
Chen, Zhenning; Shao, Xinxing; He, Xiaoyuan; Wu, Jialin; Xu, Xiangyang; Zhang, Jinlin
2017-09-01
Noninvasive, three-dimensional (3-D), full-field surface deformation measurements of the human body are important for biomedical investigations. We proposed a 3-D noninvasive, full-field body sensor based on stereo digital image correlation (stereo-DIC) for surface deformation monitoring of the human body in vivo. First, by applying an improved water-transfer printing (WTP) technique to transfer optimized speckle patterns onto the skin, the body sensor was conveniently and harmlessly fabricated directly onto the human body. Then, stereo-DIC was used to achieve 3-D noncontact and noninvasive surface deformation measurements. The accuracy and efficiency of the proposed body sensor were verified and discussed by considering different complexions. Moreover, the fabrication of speckle patterns on human skin, which has always been considered a challenging problem, was shown to be feasible, effective, and harmless as a result of the improved WTP technique. An application of the proposed stereo-DIC-based body sensor was demonstrated by measuring the pulse wave velocity of human carotid artery.
Verification of micro-scale photogrammetry for smooth three-dimensional object measurement
NASA Astrophysics Data System (ADS)
Sims-Waterhouse, Danny; Piano, Samanta; Leach, Richard
2017-05-01
By using sub-millimetre laser speckle pattern projection we show that photogrammetry systems are able to measure smooth three-dimensional objects with surface height deviations less than 1 μm. The projection of laser speckle patterns allows correspondences on the surface of smooth spheres to be found, and as a result, verification artefacts with low surface height deviations were measured. A combination of VDI/VDE and ISO standards were also utilised to provide a complete verification method, and determine the quality parameters for the system under test. Using the proposed method applied to a photogrammetry system, a 5 mm radius sphere was measured with an expanded uncertainty of 8.5 μm for sizing errors, and 16.6 μm for form errors with a 95 % confidence interval. Sphere spacing lengths between 6 mm and 10 mm were also measured by the photogrammetry system, and were found to have expanded uncertainties of around 20 μm with a 95 % confidence interval.
Kamijima, Ryo; Suzuki, Kengo; Izumo, Masaki; Kuwata, Shingo; Mizukoshi, Kei; Takai, Manabu; Kou, Seisyou; Hayashi, Akio; Kida, Keisuke; Harada, Tomoo; Akashi, Yoshihiro J.
2017-01-01
Presence of exercise-induced pulmonary hypertension (EIPH) in asymptomatic degenerative mitral regurgitation (DMR) determines prognosis. This study aimed to elucidate the mechanism and predictors of EIPH in asymptomatic DMR. Ninety-one consecutive asymptomatic patients with DMR who underwent exercise stress echocardiography were prospectively included. We obtained various conventional echocardiographic parameters at rest and during peak exercise, as well as left atrial (LA) function at rest using 2-dimensional speckle-tracking analysis. The 25 patients (33.3%) with EIPH were significantly older and had a greater ratio of mitral peak velocity of early filling to early diastolic mitral annular velocity during peak exercise than those without EIPH. LA strain (LAS)-s and LAS-e, indices of LA reservoir and conduit function, respectively, were significantly lower in those with EIPH than in those without EIPH. Multivariate analysis indicated that LAS-s was the only resting echocardiographic parameter that independently predicted EIPH, with a cut-off value of 26.9%. Furthermore, Kaplan-Meier curve analysis showed that symptom-free survival was markedly lower among those with reduced LAS-s. In conclusion, decreased LA reservoir function contributes to EIPH, and LAS-s at rest is a useful indicator for predicting EIPH in asymptomatic patients with DMR. PMID:28071674
de Waal, Koert; Phad, Nilkant
2018-03-01
Two-dimensional speckle tracking echocardiography is an emerging technique for analyzing cardiac function in newborns. Strain is a highly reliable and reproducible parameter, and reference values have been established for term and preterm newborns. Its implementation into clinical practice has been slow, partly due to lack of inter-vendor consistency. Our aim was to compare recent versions of Philips and Tomtec speckle tracking software for deformation and semiautomated volume and area measurements in neonatal intensive care patients. Longitudinal and circumferential deformation and cavity dimensions (volume, area) were determined off line from apical and short-axis images in 50 consecutive newborns with a median birthweight of 760 g (range 460-3200 g). Absolute mean endocardial global longitudinal strain measurements were similar between vendors, but with wide limits of agreement (Philips -18.9 [2.1]%, Tomtec -18.6 [2.5]%, bias -0.3 [1.7]%, and limits of agreement -3.6%-3.1%). Longitudinal strain rate and circumferential measurements showed poor correlation. All volume and area measurements correlated well between the vendors, but with significant bias. Global longitudinal strain measurements compared well between vendors but wide limits of agreement, suggesting that longitudinal measurements are preferred using similar hardware and software. © 2017, Wiley Periodicals, Inc.
Role of strain imaging in right heart disease: a comprehensive review.
Kannan, Arun; Poongkunran, Chithra; Jayaraj, Mahendran; Janardhanan, Rajesh
2014-10-01
Advances in the imaging techniques of the heart have fueled the interest in understanding of right heart pathology. Recently, speckle tracking echocardiography has shown to aid in understanding various right heart diseases and better management. Its role is well established in diagnosing right heart failure, pulmonary artery hypertension, arrhythmogenic right ventricular dysplasia and congenital heart disease. We review the basic mechanics of speckle tracking and analyze its role in various right heart conditions.
Cameli, Matteo; Ciccone, Marco M; Maiello, Maria; Modesti, Pietro A; Muiesan, Maria L; Scicchitano, Pietro; Novo, Salvatore; Palmiero, Pasquale; Saba, Pier S; Pedrinelli, Roberto
2016-05-01
Speckle tracking echocardiography (STE) is an imaging technique applied to the analysis of left atrial function. STE provides a non-Doppler, angle-independent and objective quantification of left atrial myocardial deformation. Data regarding feasibility, accuracy and clinical applications of left atrial strain are rapidly gathering. This review describes the fundamental concepts of left atrial STE, illustrates its pathophysiological background and discusses its emerging role in systemic arterial hypertension.
Zhou, Yingchao; Xiao, Hong; Wu, Jianfei; Zha, Lingfeng; Zhou, Mengchen; Li, Qianqian; Wang, Mengru; Shi, Shumei; Li, Yanze; Lyu, Liangkun; Wang, Qing; Tu, Xin; Lu, Qiulun
2018-01-01
Diabetes mellitus (DM) has been demonstrated to have a strong association with heart failure. Conventional echocardiographic analysis cannot sensitively monitor cardiac dysfunction in type I diabetic Akita hearts, but the phenotype of heart failure is observed in molecular levels during the early stages. Male Akita (Ins2WT/C96Y) mice were monitored with echocardiographic imaging at various ages, and then with conventional echocardiographic analysis and speckle-tracking based strain analyses. With speckle-tracking based strain analyses, diabetic Akita mice showed changes in average global radial strain at the age of 12 weeks, as well as decreased longitudinal strain. These changes occurred in the early stage and remained throughout the progression of diabetic cardiomyopathy in Akita mice. Speckle-tracking showed that the detailed and precise changes of cardiac deformation in the progression of diabetic cardiomyopathy in the genetic type I diabetic Akita mice were uncoupled. We monitored early-stage changes in the heart of diabetic Akita mice. We utilize this technique to elucidate the underlying mechanism for heart failure in Akita genetic type I diabetic mice. It will further advance the assessment of cardiac abnormalities, as well as the discovery of new drug treatments using Akita genetic type I diabetic mice. © 2018 The Author(s). Published by S. Karger AG, Basel.
Peng, Bo; Wang, Yuqi; Hall, Timothy J; Jiang, Jingfeng
2017-04-01
Our primary objective of this paper was to extend a previously published 2-D coupled subsample tracking algorithm for 3-D speckle tracking in the framework of ultrasound breast strain elastography. In order to overcome heavy computational cost, we investigated the use of a graphic processing unit (GPU) to accelerate the 3-D coupled subsample speckle tracking method. The performance of the proposed GPU implementation was tested using a tissue-mimicking phantom and in vivo breast ultrasound data. The performance of this 3-D subsample tracking algorithm was compared with the conventional 3-D quadratic subsample estimation algorithm. On the basis of these evaluations, we concluded that the GPU implementation of this 3-D subsample estimation algorithm can provide high-quality strain data (i.e., high correlation between the predeformation and the motion-compensated postdeformation radio frequency echo data and high contrast-to-noise ratio strain images), as compared with the conventional 3-D quadratic subsample algorithm. Using the GPU implementation of the 3-D speckle tracking algorithm, volumetric strain data can be achieved relatively fast (approximately 20 s per volume [2.5 cm ×2.5 cm ×2.5 cm]).
Biodynamic imaging for phenotypic profiling of three-dimensional tissue culture
Sun, Hao; Merrill, Daniel; An, Ran; Turek, John; Matei, Daniela; Nolte, David D.
2017-01-01
Abstract. Three-dimensional (3-D) tissue culture represents a more biologically relevant environment for testing new drugs compared to conventional two-dimensional cancer cell culture models. Biodynamic imaging is a high-content 3-D optical imaging technology based on low-coherence interferometry and digital holography that uses dynamic speckle as high-content image contrast to probe deep inside 3-D tissue. Speckle contrast is shown to be a scaling function of the acquisition time relative to the persistence time of intracellular transport and hence provides a measure of cellular activity. Cellular responses of 3-D multicellular spheroids to paclitaxel are compared among three different growth techniques: rotating bioreactor (BR), hanging-drop (HD), and nonadherent (U-bottom, UB) plate spheroids, compared with ex vivo living tissues. HD spheroids have the most homogeneous tissue, whereas BR spheroids display large sample-to-sample variability as well as spatial heterogeneity. The responses of BR-grown tumor spheroids to paclitaxel are more similar to those of ex vivo biopsies than the responses of spheroids grown using HD or plate methods. The rate of mitosis inhibition by application of taxol is measured through tissue dynamics spectroscopic imaging, demonstrating the ability to monitor antimitotic chemotherapy. These results illustrate the potential use of low-coherence digital holography for 3-D pharmaceutical screening applications. PMID:28301634
Biodynamic imaging for phenotypic profiling of three-dimensional tissue culture
NASA Astrophysics Data System (ADS)
Sun, Hao; Merrill, Daniel; An, Ran; Turek, John; Matei, Daniela; Nolte, David D.
2017-01-01
Three-dimensional (3-D) tissue culture represents a more biologically relevant environment for testing new drugs compared to conventional two-dimensional cancer cell culture models. Biodynamic imaging is a high-content 3-D optical imaging technology based on low-coherence interferometry and digital holography that uses dynamic speckle as high-content image contrast to probe deep inside 3-D tissue. Speckle contrast is shown to be a scaling function of the acquisition time relative to the persistence time of intracellular transport and hence provides a measure of cellular activity. Cellular responses of 3-D multicellular spheroids to paclitaxel are compared among three different growth techniques: rotating bioreactor (BR), hanging-drop (HD), and nonadherent (U-bottom, UB) plate spheroids, compared with ex vivo living tissues. HD spheroids have the most homogeneous tissue, whereas BR spheroids display large sample-to-sample variability as well as spatial heterogeneity. The responses of BR-grown tumor spheroids to paclitaxel are more similar to those of ex vivo biopsies than the responses of spheroids grown using HD or plate methods. The rate of mitosis inhibition by application of taxol is measured through tissue dynamics spectroscopic imaging, demonstrating the ability to monitor antimitotic chemotherapy. These results illustrate the potential use of low-coherence digital holography for 3-D pharmaceutical screening applications.
Rabbi, Md Shifat-E; Hasan, Md Kamrul
2017-02-01
Strain imaging though for solid lesions provides an effective way for determining their pathologic condition by displaying the tissue stiffness contrast, for fluid filled lesions such an imaging is yet an open problem. In this paper, we propose a novel speckle content based strain imaging technique for visualization and classification of fluid filled lesions in elastography after automatic identification of the presence of fluid filled lesions. Speckle content based strain, defined as a function of speckle density based on the relationship between strain and speckle density, gives an indirect strain value for fluid filled lesions. To measure the speckle density of the fluid filled lesions, two new criteria based on oscillation count of the windowed radio frequency signal and local variance of the normalized B-mode image are used. An improved speckle tracking technique is also proposed for strain imaging of the solid lesions and background. A wavelet-based integration technique is then proposed for combining the strain images from these two techniques for visualizing both the solid and fluid filled lesions from a common framework. The final output of our algorithm is a high quality composite strain image which can effectively visualize both solid and fluid filled breast lesions in addition to the speckle content of the fluid filled lesions for their discrimination. The performance of our algorithm is evaluated using the in vivo patient data and compared with recently reported techniques. The results show that both the solid and fluid filled lesions can be better visualized using our technique and the fluid filled lesions can be classified with good accuracy. Copyright © 2016 Elsevier B.V. All rights reserved.
Mokhles, Palwasha; van den Bosch, Annemien E; Vletter-McGhie, Jackie S; Van Domburg, Ron T; Ruys, Titia P E; Kauer, Floris; Geleijnse, Marcel L; Roos-Hesselink, Jolien W
2013-09-01
The twisting motion of the heart has an important role in the function of the left ventricle. Speckle tracking echocardiography is able to quantify left ventricular (LV) rotation and twist. So far this new technique has not been used in congenital heart disease patients. The aim of our study was to investigate the feasibility and the intra- and inter-observer reproducibility of LV rotation parameters in adult patients with congenital heart disease. The study population consisted of 66 consecutive patients seen in the outpatient clinic (67% male, mean age 31 ± 7.7 years, NYHA class 1 ± 0.3) with a variety of congenital heart disease. First, feasibility was assessed in all patients. Intra- and inter-observer reproducibility was assessed for the patients in which speckle tracking echocardiography was feasible. Adequate image quality, for performing speckle echocardiography, was found in 80% of patients. The bias for the intra-observer reproducibility of the LV twist was 0.0°, with 95% limits of agreement of -2.5° and 2.5° and for interobserver reproducibility the bias was 0.0°, with 95% limits of agreement of -3.0° and 3.0°. Intra- and inter-observer measurements showed a strong correlation (0.86 and 0.79, respectively). Also a good repeatability was seen. The mean time to complete full analysis per subject for the first and second measurement was 9 and 5 minutes, respectively. Speckle tracking echocardiography is feasible in 80% of adult patients with congenital heart disease and shows excellent intra- and inter-observer reproducibility. © 2013, Wiley Periodicals, Inc.
Smith, Matthew B; Karatekin, Erdem; Gohlke, Andrea; Mizuno, Hiroaki; Watanabe, Naoki; Vavylonis, Dimitrios
2011-10-05
Analysis of particle trajectories in images obtained by fluorescence microscopy reveals biophysical properties such as diffusion coefficient or rates of association and dissociation. Particle tracking and lifetime measurement is often limited by noise, large mobilities, image inhomogeneities, and path crossings. We present Speckle TrackerJ, a tool that addresses some of these challenges using computer-assisted techniques for finding positions and tracking particles in different situations. A dynamic user interface assists in the creation, editing, and refining of particle tracks. The following are results from application of this program: 1), Tracking single molecule diffusion in simulated images. The shape of the diffusing marker on the image changes from speckle to cloud, depending on the relationship of the diffusion coefficient to the camera exposure time. We use these images to illustrate the range of diffusion coefficients that can be measured. 2), We used the program to measure the diffusion coefficient of capping proteins in the lamellipodium. We found values ∼0.5 μm(2)/s, suggesting capping protein association with protein complexes or the membrane. 3), We demonstrate efficient measuring of appearance and disappearance of EGFP-actin speckles within the lamellipodium of motile cells that indicate actin monomer incorporation into the actin filament network. 4), We marked appearance and disappearance events of fluorescently labeled vesicles to supported lipid bilayers and tracked single lipids from the fused vesicle on the bilayer. This is the first time, to our knowledge, that vesicle fusion has been detected with single molecule sensitivity and the program allowed us to perform a quantitative analysis. 5), By discriminating between undocking and fusion events, dwell times for vesicle fusion after vesicle docking to membranes can be measured. Copyright © 2011 Biophysical Society. Published by Elsevier Inc. All rights reserved.
An adaptive front tracking technique for three-dimensional transient flows
NASA Astrophysics Data System (ADS)
Galaktionov, O. S.; Anderson, P. D.; Peters, G. W. M.; van de Vosse, F. N.
2000-01-01
An adaptive technique, based on both surface stretching and surface curvature analysis for tracking strongly deforming fluid volumes in three-dimensional flows is presented. The efficiency and accuracy of the technique are demonstrated for two- and three-dimensional flow simulations. For the two-dimensional test example, the results are compared with results obtained using a different tracking approach based on the advection of a passive scalar. Although for both techniques roughly the same structures are found, the resolution for the front tracking technique is much higher. In the three-dimensional test example, a spherical blob is tracked in a chaotic mixing flow. For this problem, the accuracy of the adaptive tracking is demonstrated by the volume conservation for the advected blob. Adaptive front tracking is suitable for simulation of the initial stages of fluid mixing, where the interfacial area can grow exponentially with time. The efficiency of the algorithm significantly benefits from parallelization of the code. Copyright
Diagnosing cysts with correlation coefficient images from 2-dimensional freehand elastography.
Booi, Rebecca C; Carson, Paul L; O'Donnell, Matthew; Richards, Michael S; Rubin, Jonathan M
2007-09-01
We compared the diagnostic potential of using correlation coefficient images versus elastograms from 2-dimensional (2D) freehand elastography to characterize breast cysts. In this preliminary study, which was approved by the Institutional Review Board and compliant with the Health Insurance Portability and Accountability Act, we imaged 4 consecutive human subjects (4 cysts, 1 biopsy-verified benign breast parenchyma) with freehand 2D elastography. Data were processed offline with conventional 2D phase-sensitive speckle-tracking algorithms. The correlation coefficient in the cyst and surrounding tissue was calculated, and appearances of the cysts in the correlation coefficient images and elastograms were compared. The correlation coefficient in the cysts was considerably lower (14%-37%) than in the surrounding tissue because of the lack of sufficient speckle in the cysts, as well as the prominence of random noise, reverberations, and clutter, which decorrelated quickly. Thus, the cysts were visible in all correlation coefficient images. In contrast, the elastograms associated with these cysts each had different elastographic patterns. The solid mass in this study did not have the same high decorrelation rate as the cysts, having a correlation coefficient only 2.1% lower than that of surrounding tissue. Correlation coefficient images may produce a more direct, reliable, and consistent method for characterizing cysts than elastograms.
Sengupta, Shantanu P; Jaju, Rahul; Nugurwar, Abhijeet; Caracciolo, Giuseppe; Sengupta, Partho P
2012-01-01
The status of left ventricle in sickle cell anemia presenting in sickle crisis and follow up has been minimally studied in past. To determine the left ventricular (LV) myocardial performance in these patients, we performed the study to assess two dimensional strains imaging which allowed a rapid and an accurate analysis of global and regional LV myocardial performance in longitudinal, radial, and circumferential directions. In this prospective study, 2-dimensional echocardiography (2DE) images of the LV were obtained in 52 subjects which included 32 patients (23 ± 8yrs, 16 male) with homozygous sickle cell anemia (SCA) in sickle cell crisis and 20 healthy controls (23 ± 5 yrs, 11 male) using apical 4-chamber and parasternal short-axis at the basal, mid, and apical levels. Of these 32 patients, 2DE was performed again in 18 patients in follow up (8 months ± 5 days). Longitudinal, circumferential and radial strains (LS, CS and RS respectively) were quantified and compared in an 18-segment model using a novel speckle tracking system (2D Cardiac Performance Analysis, TomTec Imaging System, Munich, Germany). There was no significant difference in LV ejection fraction between both the groups (59.32 ± 12.6 vs. 52.3 ± 7.9; p-value > 0.05). In comparison with normal controls and follow up of sickle cell patients, peak LS was significantly attenuated in the subendocardial and subepicardial regions during sickle cell crisis (p < 0.05). However, a significant reduction in circumferential strain was evident only in subepicardial region (p < 0.001). Also patients in sickle cell crisis showed significantly higher radial strain parameters than controls (p < 0.001). Patients with SCA presenting in sickle cell crisis have reduced longitudinal shortening. LV myocardial performance remains unaltered due to relatively preserved circumferential shortening and increased radial thickening. Copyright © 2012 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Alizade, Elnur; Avci, Anil; Tabakcı, Mehmet Mustafa; Toprak, Cuneyt; Zehir, Regayip; Acar, Goksel; Kargin, Ramazan; Emiroğlu, Mehmet Yunas; Akçakoyun, Mustafa; Pala, Selçuk
2016-08-01
Right ventricular (RV) effects of long-term use of anabolic-androgenic steroids (AAS) are not clearly known. The aim of this study was to assess RV systolic functions by two-dimensional speckle tracking echocardiography (2DSTE) in AAS user and nonuser bodybuilders. A total of 33 competitive male bodybuilders (15 AAS users, 18 AAS nonusers) were assessed. To assess RV systolic functions, all participants underwent standard two-dimensional and Doppler echocardiography, and 2DSTE. Interventricular septal thickness, left ventricle posterior wall thickness, relative wall thickness, and left ventricle mass index were significantly higher in AAS users than nonusers. While standard diastolic parameters were not statistically different between the groups, tissue Doppler parameters including RV E' and E'/A' were lower in AAS users than nonusers (10.1 ± 2.0 vs. 12.7 ± 2.1; P = 0.001, 1.1 ± 0.1 vs. 1.5 ± 0.4; P = 0.009, respectively). Tricuspid annular plane systolic excursion, RV fractional area change, and RV S' were in normal ranges. However, RV S' was found to be lower in users than nonusers (12.2 ± 2.2 vs. 14.6 ± 2.8, P = 0.011). RV free wall longitudinal strain and strain rate were decreased in AAS users in comparison with nonusers (-20.2 ± 3.1 vs. -23.3 ± 3.5; P = 0.012, -3.2 ± 0.1 vs. -3.4 ± 0.1; P = 0.022, respectively). In addition, there were good correlations between 2DSTE parameters and RV S', E', and E'/A'. Despite normal standard systolic echo parameters, peak systolic RV free wall strain and strain rate were reduced in AAS user bodybuilders in comparison with nonusers. Strain and strain rate by 2DSTE may be useful for early determination of subclinical RV dysfunction in AAS user bodybuilders. © 2016, Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Hsieh, Bao-Yu; Song, Shaozhen; Nguyen, Thu-Mai; Yoon, Soon Joon; Shen, Tueng; Wang, Ruikang; O'Donnell, Matthew
2016-03-01
Phase-sensitive optical coherence tomography (PhS-OCT) can be utilized for quantitative shear-wave elastography using speckle tracking. However, current approaches cannot directly reconstruct elastic properties in speckle-less or speckle-free regions, for example within the crystalline lens in ophthalmology. Investigating the elasticity of the crystalline lens could improve understanding and help manage presbyopia-related pathologies that change biomechanical properties. We propose to reconstruct the elastic properties in speckle-less regions by sequentially launching shear waves with moving acoustic radiation force (mARF), and then detecting the displacement at a specific speckle-generating position, or limited set of positions, with PhS-OCT. A linear ultrasound array (with a center frequency of 5 MHz) interfaced with a programmable imaging system was designed to launch shear waves by mARF. Acoustic sources were electronically translated to launch shear waves at laterally shifted positions, where displacements were detected by speckle tracking images produced by PhS-OCT operating in M-B mode with a 125-kHz A-line rate. Local displacements were calculated and stitched together sequentially based on the distance between the acoustic source and the detection beam. Shear wave speed, and the associated elasticity map, were then reconstructed based on a time-of-flight algorithm. In this study, moving-source shear wave elasticity imaging (SWEI) can highlight a stiff inclusion within an otherwise homogeneous phantom but with a CNR increased by 3.15 dB compared to a similar image reconstructed with moving-detector SWEI. Partial speckle-free phantoms were also investigated to demonstrate that the moving-source sequence could reconstruct the elastic properties of speckle-free regions. Results show that harder inclusions within the speckle-free region can be detected, suggesting that this imaging method may be able to detect the elastic properties of the crystalline lens.
Measurement of ventricular torsion by two-dimensional ultrasound speckle tracking imaging.
Notomi, Yuichi; Lysyansky, Peter; Setser, Randolph M; Shiota, Takahiro; Popović, Zoran B; Martin-Miklovic, Maureen G; Weaver, Joan A; Oryszak, Stephanie J; Greenberg, Neil L; White, Richard D; Thomas, James D
2005-06-21
We sought to examine the accuracy/consistency of a novel ultrasound speckle tracking imaging (STI) method for left ventricular torsion (LVtor) measurement in comparison with tagged magnetic resonance imaging (MRI) (a time-domain method similar to STI) and Doppler tissue imaging (DTI) (a velocity-based approach). Left ventricular torsion from helically oriented myofibers is a key parameter of cardiac performance but is difficult to measure. Ultrasound STI is potentially suitable for measurement of angular motion because of its angle-independence. We acquired basal and apical short-axis left ventricular (LV) images in 15 patients to estimate LVtor by STI and compare it with tagged MRI and DTI. Left ventricular torsion was defined as the net difference of LV rotation at the basal and apical planes. For the STI analysis, we used high-frame (104 +/- 12 frames/s) second harmonic two-dimensional images. Data on 13 of 15 patients were usable for STI analysis, and LVtor profile estimated by STI strongly correlated with those by tagged MRI (y = 0.95x + 0.19, r = 0.93, p < 0.0001, analyzed by repeated-measures regression models). The STI torsional velocity profile also correlated well with that by the DTI method (y = 0.79x + 2.4, r = 0.76, p < 0.0001, by repeated-measures regression models) with acceptable bias. The STI estimation of LVtor is concordant with those analyzed by tagged MRI (data derived from tissue displacement) and also showed good agreement with those by DTI (data derived from tissue velocity). Ultrasound STI is a promising new method to assess LV torsional deformation and may make the assessment more available in clinical and research cardiology.
Huang, He; Jing, Xian-chao; Hu, Zhang-xue; Chen, Xi; Liu, Xiao-qin
2015-12-01
To observe the ventricular global and regional function of the patients with systemic amyloidosis using two-dimensional speckle tracking echocardiography. The study enrolled 31 consecutive biopsy-proved patients with systemic amyloidosis who underwent echocardiographic examination and EF ≥ 55% and 37 age- and gender-matched healthy controls. We compared systolic strain and strain rate, diastolic strain rate, time to peak strain, peak delay time in longitudinal, radial, circumferential directions in 16 left ventricular segments. The global peak systolic longitudinal and radial strain of left ventricle, peak systolic longitudinal strain and strain rate, diastolic strain rate of right ventricular free wall were also compared. (1) Global peak systolic longitudinal strain (GPSLS), peak systolic longitudinal strain (PSLS) and strain rate (PSLSR), peak early diastolic longitudinal strain rate (PELSR) in 16 segments were decreased in case (P < 0.05). (2) Peak systolic radial strain and strain rate of inferoseptum and inferolateral at the level of papillary muscle were lower (P < 0.05), and peak early diastolic radial strain rate (PERSR) was reduced (P < 0.05). (3) Peak early diastolic circumferential strain rate was lower (P < 0.05). (4) Time to peak systolic longitudinal, radial, circumferential strain was longer, and peak delay time at the same level retarded (P < 0.05). (5) Into right ventricular wall, PSLS and PSLSR at mid-segment, and PSLSR, PELSR, peak atrial systolic longitudinal strain rate (PALSR) at basal were reduced (P < 0.05). (6) Inverse correlation between interventricular septum (IVS) thickness and GPSLS and GPSRS was found (P < 0.05). Systolic and diastolic dysfunction existed in systemic amyloidosis with preserved EF. Mechanical contraction disorder may be one reason for systolic dysfunction. GPLSR and GPRSR were negatively related to IVS thickness. © 2015, Wiley Periodicals, Inc.
Volschan, I C M; Kasuki, L; Silva, C M S; Alcantara, M L; Saraiva, R M; Xavier, S S; Gadelha, M R
2017-06-01
Speckle tracking echocardiography (STE) allows for the study of myocardial strain (ε), a marker of early and subclinical ventricular systolic dysfunction. Cardiac disease may be present in patients with acromegaly; however, STE has never been used to evaluate these patients. To evaluate left ventricular (LV) global longitudinal strain in patients with active acromegaly with normal LV systolic function. Cross-sectional clinical study. Patients with active acromegaly with no detectable heart disease and a control group were matched for age, gender, arterial hypertension and diabetes mellitus underwent STE. Global LV longitudinal ε (GLS), left ventricular mass index (LVMi), left ventricular ejection fraction (LVEF) and relative wall thickness (RWT) were obtained via two-dimensional (2D) echocardiography using STE. Thirty-seven patients with active acromegaly (mean age 45.6 ± 13.8; 48.6% were males) and 48 controls were included. The mean GLS was not significantly different between the acromegaly group and the control group (in %, -20.1 ± 3.1 vs. -19.4 ± 2.2, p = 0.256). Mean LVMi was increased in the acromegaly group (in g/m 2 , 101.6 ± 27.1 vs. 73.2 ± 18.6, p < 0.01). There was a negative correlation between LVMi and GLS (r = -0.39, p = 0.01). Acromegaly patients, despite presenting with a higher LVMi when analyzed by 2D echocardiography, did not present with impairment in the strain when compared to a control group; this finding indicates a low chance of evolution to systolic dysfunction and agrees with recent studies that show a lower frequency of cardiac disease in these patients.
Leite, Luís; Teixeira, Rogério; Oliveira-Santos, Manuel; Barbosa, António; Martins, Rui; Castro, Graça; Gonçalves, Lino; Pego, Mariano
2016-08-01
Degenerative aortic valve disease (AVD) is a complex disorder that goes beyond valve itself, also undermining aortic wall. We aimed to assess the ascending aortic mechanics with two-dimensional speckle tracking echocardiography (2DSTE) in patients with aortic regurgitation (AR) and hypothesized a relationship with degree of AR. Aortic mechanics were then compared with those of similarly studied healthy controls and patients with aortic stenosis (AS); finally, we aimed to assess the prognostic significance of vascular mechanics in AVD. Overall, 73 patients with moderate-to-severe AR and 22 healthy subjects were enrolled, alongside a previously examined cohort (N = 45) with moderate-to-severe AS. Global circumferential ascending aortic strain (CAAS) and strain rate (CAASR) served as indices of aortic deformation; corrected CAAS was calculated as CAAS/pulse pressure (PP). Median clinical follow-up was 438 days. In patients with severe (vs. moderate) AR, CAASR (1.53 ± 0.29/sec vs. 1.90 ± 0.62/sec, P < 0.05) and corrected CAAS (0.14 ± 0.06%/mmHg vs. 0.19 ± 0.08%/mmHg, P < 0.05) were significantly lower, whereas CAAS did not differ significantly. Measurers of aortic mechanics (CAAS, corrected CAAS, CAASR) differed significantly (all P < 0.01) in patients with AS and AR and in healthy subjects, with lower values seen in patients with AS. In follow-up, survival rate of AVD patients with baseline CAASR >0.88/sec was significantly higher (log rank, 97.4% vs. 73.0%; P = 0.03). Quantitative measures of aortic mechanics were lower for AS patients, suggesting a more significant derangement of aortic elastic properties. In the context of AVD, vascular mechanics assessment proved useful in gauging clinical prognosis. © 2016, Wiley Periodicals, Inc.
Wu, Wei-Chun; Ma, Hong; Xie, Rong-Ai; Gao, Li-Jian; Tang, Yue; Wang, Hao
2016-04-01
This study evaluated the role of two-dimensional speckle tracking echocardiography (2DSTE) for predicting left ventricular (LV) diastolic dysfunction in pacing-induced canine heart failure. Pacing systems were implanted in 8 adult mongrel dogs, and continuous rapid right ventricular pacing (RVP, 240 beats/min) was maintained for 2 weeks. The obtained measurements from 2DSTE included global strain rate during early diastole (SRe) and during late diastole (SRa) in the longitudinal (L-SRe, L-SRa), circumferential (C-SRe, C-SRa), and radial directions (R-SRe, R-SRa). Changes in heart morphology were observed by light microscopy and transmission electron microscopy at 2 weeks. The onset of LV diastolic dysfunction with early systolic dysfunction occurred 3 days after RVP initiation. Most of the strain rate imaging indices were altered at 1 or 3 days after RVP onset and continued to worsen until heart failure developed. Light and transmission electron microscopy showed myocardial vacuolar degeneration and mitochondrial swelling in the left ventricular at 2 weeks after RVP onset. Pearson's correlation analysis revealed that parameters of conventional echocardiography and 2DSTE showed moderate correlation with LV pressure parameters, including E/Esep' (r = 0.58, P < 0.01), L-SRe (r = -0.58, P < 0.01), E/L-SRe (r = 0.65, P < 0.01), and R-SRe (r = 0.53, P < 0.01). ROC curves analysis showed that these indices of conventional echocardiography and strain rate imaging could effectively predict LV diastolic dysfunction (area under the curve: E/Esep' 0.78; L-SRe 0.84; E/L-SRe 0.80; R-SRe 0.80). 2DSTE was a sensitive and accurate technique that could be used for predicting LV diastolic dysfunction in canine heart failure model. © 2015, Wiley Periodicals, Inc.
2010-01-01
Background Echocardiography is the method of choice when one wishes to examine myocardial function. Qualitative assessment of the 2D grey scale images obtained is subjective, and objective methods are required. Speckle Tracking Ultrasound is an emerging technology, offering an objective mean of quantifying left ventricular wall motion. However, before a new ultrasound technology can be adopted in the clinic, accuracy and reproducibility needs to be investigated. Aim It was hypothesized that the collection of ultrasound sample data from an in vitro model could be automated. The aim was to optimize an in vitro model to allow for efficient collection of sample data. Material & Methods A tissue-mimicking phantom was made from water, gelatin powder, psyllium fibers and a preservative. Sonomicrometry crystals were molded into the phantom. The solid phantom was mounted in a stable stand and cyclically compressed. Peak strain was then measured by Speckle Tracking Ultrasound and sonomicrometry. Results We succeeded in automating the acquisition and analysis of sample data. Sample data was collected at a rate of 200 measurement pairs in 30 minutes. We found good agreement between Speckle Tracking Ultrasound and sonomicrometry in the in vitro model. Best agreement was 0.83 ± 0.70%. Worst agreement was -1.13 ± 6.46%. Conclusions It has been shown possible to automate a model that can be used for evaluating the in vitro accuracy and precision of ultrasound modalities measuring deformation. Sonomicrometry and Speckle Tracking Ultrasound had acceptable agreement. PMID:20822532
Chao, Pei-Kuang; Wang, Chun-Li; Chan, Hsiao-Lung
2012-03-01
Predicting response after cardiac resynchronization therapy (CRT) has been a challenge of cardiologists. About 30% of selected patients based on the standard selection criteria for CRT do not show response after receiving the treatment. This study is aimed to build an intelligent classifier to assist in identifying potential CRT responders by speckle-tracking radial strain based on echocardiograms. The echocardiograms analyzed were acquired before CRT from 26 patients who have received CRT. Sequential forward selection was performed on the parameters obtained by peak-strain timing and phase space reconstruction on speckle-tracking radial strain to find an optimal set of features for creating intelligent classifiers. Support vector machine (SVM) with a linear, quadratic, and polynominal kernel were tested to build classifiers to identify potential responders and non-responders for CRT by selected features. Based on random sub-sampling validation, the best classification performance is correct rate about 95% with 96-97% sensitivity and 93-94% specificity achieved by applying SVM with a quadratic kernel on a set of 3 parameters. The selected 3 parameters contain both indexes extracted by peak-strain timing and phase space reconstruction. An intelligent classifier with an averaged correct rate, sensitivity and specificity above 90% for assisting in identifying CRT responders is built by speckle-tracking radial strain. The classifier can be applied to provide objective suggestion for patient selection of CRT. Copyright © 2011 Elsevier B.V. All rights reserved.
Potential of the McMath-Pierce 1.6-Meter Solar Telescope for Speckle Interferometry
NASA Astrophysics Data System (ADS)
Harshaw, Richard; Jones, Gregory; Wiley, Edward; Boyce, Patrick; Branston, Detrick; Rowe, David; Genet, Russell
2015-09-01
We explored the aiming and tracking accuracy of the McMath-Pierce 1.6 m solar telescope at Kitt Peak National Observatory as part of an investigation of using this telescope for speckle interferometry of close visual double stars. Several slews of various lengths looked for hysteresis in the positioning system (we found none of significance) and concluded that the 1.6 m telescope would make a useful telescope for speckle interferometry.
Peng, Bo; Wang, Yuqi; Hall, Timothy J; Jiang, Jingfeng
2017-01-01
Our primary objective of this work was to extend a previously published 2D coupled sub-sample tracking algorithm for 3D speckle tracking in the framework of ultrasound breast strain elastography. In order to overcome heavy computational cost, we investigated the use of a graphic processing unit (GPU) to accelerate the 3D coupled sub-sample speckle tracking method. The performance of the proposed GPU implementation was tested using a tissue-mimicking (TM) phantom and in vivo breast ultrasound data. The performance of this 3D sub-sample tracking algorithm was compared with the conventional 3D quadratic sub-sample estimation algorithm. On the basis of these evaluations, we concluded that the GPU implementation of this 3D sub-sample estimation algorithm can provide high-quality strain data (i.e. high correlation between the pre- and the motion-compensated post-deformation RF echo data and high contrast-to-noise ratio strain images), as compared to the conventional 3D quadratic sub-sample algorithm. Using the GPU implementation of the 3D speckle tracking algorithm, volumetric strain data can be achieved relatively fast (approximately 20 seconds per volume [2.5 cm × 2.5 cm × 2.5 cm]). PMID:28166493
Chen, Zhenning; Shao, Xinxing; He, Xiaoyuan; Wu, Jialin; Xu, Xiangyang; Zhang, Jinlin
2017-09-01
Noninvasive, three-dimensional (3-D), full-field surface deformation measurements of the human body are important for biomedical investigations. We proposed a 3-D noninvasive, full-field body sensor based on stereo digital image correlation (stereo-DIC) for surface deformation monitoring of the human body in vivo. First, by applying an improved water-transfer printing (WTP) technique to transfer optimized speckle patterns onto the skin, the body sensor was conveniently and harmlessly fabricated directly onto the human body. Then, stereo-DIC was used to achieve 3-D noncontact and noninvasive surface deformation measurements. The accuracy and efficiency of the proposed body sensor were verified and discussed by considering different complexions. Moreover, the fabrication of speckle patterns on human skin, which has always been considered a challenging problem, was shown to be feasible, effective, and harmless as a result of the improved WTP technique. An application of the proposed stereo-DIC-based body sensor was demonstrated by measuring the pulse wave velocity of human carotid artery. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
A method to transfer speckle patterns for digital image correlation
NASA Astrophysics Data System (ADS)
Chen, Zhenning; Quan, Chenggen; Zhu, Feipeng; He, Xiaoyuan
2015-09-01
A simple and repeatable speckle creation method based on water transfer printing (WTP) is proposed to reduce artificial measurement error for digital image correlation (DIC). This technique requires water, brush, and a piece of transfer paper that is made of prefabricated decal paper, a protected sheet, and printed speckle patterns. The speckle patterns are generated and optimized via computer simulations, and then printed on the decal paper. During the experiments, operators can moisten the basement with water and the brush, so that digital patterns can be simply transferred to the carriers’ surfaces. Tensile experiments with an extended three-dimensional (3D) DIC system are performed to test and verify the validity of WTP patterns. It is shown that by comparing with a strain gage, the strain error is less than 50μɛ in a uniform tensile test. From five carbon steel tensile experiments, Lüders bands in both WTP patterns and spray paint patterns are demonstrated to propagate symmetrically. In the necking part where the strain is up to 66%, WTP patterns are proved to adhere to the specimens well. Hence, WTP patterns are capable of maintaining coherence and adherence to the specimen surface. The transfer paper, working as the role of strain gage in the electrometric method, will contribute to speckle creation.
Demirkıran, Aykut; Albayrak, Neslihan; Albayrak, Yakup; Zorkun, Cafer Sadık
2018-06-01
There is growing evidence regarding the numerous adverse effects of synthetic cannabinoids (SCBs) on the cardiovascular system; however, no studies have shown the cardiovascular effects of opioids using strain echocardiography. This study examines the cardiac structure and function using echocardiographic strain imaging in heroin and synthetic cannabinoid users. This double-blind study included patients who were admitted or referred to a rehabilitation center for heroin (n=31) and synthetic cannabinoid users (n=30). Heroin users and synthetic cannabinoid users were compared with healthy volunteers (n=32) using two-dimensional (2D) speckle-tracking (ST) echocardiography. No differences were found in the baseline characteristics and 2D echocardiography values. The mean global longitudinal strain value was -20.5%±2.4% for SCB users, -22.3%±2.4% for opioid users, and -22.5%±2.2% for healthy volunteers (p=0.024). The mean apical 2-chamber (AP2C) L-strain values were -20.1%±3.1%, -22.4%±3.0%, and -22.3%±2.8% for SCB users, opioid users, and healthy volunteers, respectively (p=0.032). The mean apical 4-chamber (AP4C) L-strain values were -20.7%±2.5% for SCB users, -23.2%±3.2% for opioid users, and -23.8%±3.1% for healthy volunteers (p<0.001). SCBs are potential causes of subclinical left ventricular dysfunction.
Saccheri, María Cristina; Cianciulli, Tomás Francisco; Morita, Luis Alberto; Méndez, Ricardo José; Beck, Martín Alejandro; Guerra, Juan Enrique; Cozzarin, Alberto; Puente, Luciana Jimena; Balletti, Lorena Romina; Lax, Jorge Alberto
2017-04-26
To explore regional systolic strain of midwall and endocardial segments using speckle tracking echocardiography in patients with apical hypertrophic cardiomyopathy (HCM). We prospectively assessed 20 patients (mean age 53 ± 16 years, range: 18-81 years, 10 were male), with apical HCM. We measured global longitudinal peak systolic strain (GLPSS) in the midwall and endocardium of the left ventricle. The diastolic thickness of the 4 apical segments was 16.25 ± 2.75 mm. All patients had a normal global systolic function with a fractional shortening of 50% ± 8%. In spite of supernormal left ventricular (LV) systolic function, midwall GLPSS was decreased in all patients, more in the apical (-7.3% ± -8.8%) than in basal segments (-15.5% ± -6.93%), while endocardial GLPPS was significantly greater and reached normal values (apical: -22.8% ± -7.8%, basal: -17.9% ± -7.5%). This study shows that two-dimensional strain was decreased mainly confined to the mesocardium, while endocardium myocardial deformation was preserved in HCM and allowed to identify subclinical LV dysfunction. This transmural heterogeneity in systolic strain had not been previously described in HCM and could be explained by the distribution of myofibrillar disarray in deep myocardial areas. The clinical application of this novel finding may help further understanding of the pathophysiology of HCM.
New echocardiographic techniques for evaluation of left atrial mechanics.
Todaro, Maria Chiara; Choudhuri, Indrajit; Belohlavek, Marek; Jahangir, Arshad; Carerj, Scipione; Oreto, Lilia; Khandheria, Bijoy K
2012-12-01
Until recently the left atrium had been subordinate to the left ventricle, but cardiologists now recognize that left atrial (LA) function is indispensable to normal circulatory performance. Transthoracic two-dimensional (2D) and Doppler echocardiography can elucidate parameters of LA function non-invasively. Yet, with the advent of 2D speckle-tracking echocardiography, we are able to detect early LA dysfunction even before structural changes occur. This is pivotal in some common disease states, such as atrial fibrillation, hypertension, and heart failure, in which LA deformation parameters can influence clinical management. However, a unique standardized technique to investigate LA deformation needs to be validated.
Multimodality Imaging in Cardiooncology
Pizzino, Fausto; Vizzari, Giampiero; Qamar, Rubina; Bomzer, Charles; Carerj, Scipione; Khandheria, Bijoy K.
2015-01-01
Cardiotoxicity represents a rising problem influencing prognosis and quality of life of chemotherapy-treated patients. Anthracyclines and trastuzumab are the drugs most commonly associated with development of a cardiotoxic effect. Heart failure, myocardial ischemia, hypertension, myocarditis, and thrombosis are typical manifestation of cardiotoxicity by chemotherapeutic agents. Diagnosis and monitoring of cardiac side-effects of cancer treatment is of paramount importance. Echocardiography and nuclear medicine methods are widely used in clinical practice and left ventricular ejection fraction is the most important parameter to asses myocardial damage secondary to chemotherapy. However, left ventricular ejection decrease is a delayed phenomenon, occurring after a long stage of silent myocardial damage that classic imaging methods are not able to detect. New imaging techniques including three-dimensional echocardiography, speckle tracking echocardiography, and cardiac magnetic resonance have demonstrated high sensitivity in detecting the earliest alteration of left ventricular function associated with future development of chemotherapy-induced cardiomyopathy. Early diagnosis of cardiac involvement in cancer patients can allow for timely and adequate treatment management and the introduction of cardioprotective strategies. PMID:26300915
Cruz-Perez, Benjamin; Tang, Junhua; Morris, Hugh J.; Palko, Joel R.; Pan, Xueliang; Hart, Richard T.; Liu, Jun
2014-01-01
This study aimed to characterize the mechanical responses of the sclera, the white outer coat of the eye, under equal-biaxial loading with unrestricted shear. An ultrasound speckle tracking technique was used to measure tissue deformation through sample thickness, expanding the capabilities of surface strain techniques. Eight porcine scleral samples were tested within 72 hours postmortem. High resolution ultrasound scans of scleral cross-sections along the two loading axes were acquired at 25 consecutive biaxial load levels. An additional repeat of the biaxial loading cycle was performed to measure a third normal strain emulating a strain gauge rosette for calculating the in-plane shear. The repeatability of the strain measurements during identical biaxial ramps was evaluated. A correlation-based ultrasound speckle tracking algorithm was used to compute the displacement field and determine the distributive strains in the sample cross-sections. A Fung type constitutive model including a shear term was used to determine the material constants of each individual specimen by fitting the model parameters to the experimental stress-strain data. A non-linear stress-strain response was observed in all samples. The meridian direction had significantly larger strains than the circumferential direction during equal-biaxial loadings (P’s<0.05). The stiffness along the two directions were also significantly different (P=0.02) but highly correlated (R2=0.8). These results showed that the mechanical properties of the porcine sclera were nonlinear and anisotropic under biaxial loading. This work has also demonstrated the feasibility of using ultrasound speckle tracking for strain measurements during mechanical testing. PMID:24438767
Visual based laser speckle pattern recognition method for structural health monitoring
NASA Astrophysics Data System (ADS)
Park, Kyeongtaek; Torbol, Marco
2017-04-01
This study performed the system identification of a target structure by analyzing the laser speckle pattern taken by a camera. The laser speckle pattern is generated by the diffuse reflection of the laser beam on a rough surface of the target structure. The camera, equipped with a red filter, records the scattered speckle particles of the laser light in real time and the raw speckle image of the pixel data is fed to the graphic processing unit (GPU) in the system. The algorithm for laser speckle contrast analysis (LASCA) computes: the laser speckle contrast images and the laser speckle flow images. The k-mean clustering algorithm is used to classify the pixels in each frame and the clusters' centroids, which function as virtual sensors, track the displacement between different frames in time domain. The fast Fourier transform (FFT) and the frequency domain decomposition (FDD) compute the modal properties of the structure: natural frequencies and damping ratios. This study takes advantage of the large scale computational capability of GPU. The algorithm is written in Compute Unifies Device Architecture (CUDA C) that allows the processing of speckle images in real time.
Abdulrahman, Randa M; Delgado, Victoria; Hoftijzer, Hendrieke C; Ng, Arnold C T; Ewe, See Hooi; Marsan, Nina Ajmone; Holman, Eduard R; Hovens, Guido C; Corssmit, Eleonora P; Romijn, Johannes A; Bax, Jeroen J; Smit, Johannes W A
2011-05-01
The cardiovascular effects of transitions from exogenous subclinical hyperthyroidism to short-term overt hypothyroidism in patients treated for differentiated thyroid carcinoma remain unclear. The present study aims at evaluating the changes in multidirectional myocardial strain using two-dimensional (2D) speckle tracking during this controlled transition from exogenous subclinical hyperthyroidism to overt hypothyroidism. The study included 14 patients with differentiated thyroid carcinoma on thyrotropin suppressive thyroxine substitution who were subsequently withdrawn from thyroxine for 4 weeks. Cardiac function was assessed by 2D speckle tracking echocardiography before and 1 and 4 weeks after withdrawal and compared with values obtained in a control group of 24 individuals. At baseline, the left ventricular dimensions were significantly higher in patients as compared with controls. Using 2D speckle tracking imaging, the patients had significantly impaired baseline myocardial systolic function in the circumferential (-16.0% ± 2.1% vs. -19.2% ± 3.0%, p = 0.001) and longitudinal (-17.1% ± 2.5% vs. -19.7% ± 3.0%, p = 0.001) directions as compared with controls. Withdrawal of thyroid hormone did not induce significant changes in left ventricular dimensions or systolic function. During the transition from exogenous subclinical hyperthyroidism to overt hypothyroidism, a significant improvement in circumferential and longitudinal systolic shortening was observed and returned to abnormal values when the patients were overt hypothyroid (circumferential strain: from -16.0% ± 2.1% to -18.6% ± 1.9% and -14.7% ± 2.8%, p < 0.005; longitudinal strain: from -17.1% ± 2.5% to -18.8% ± 1.4% and -16.3% ± 1.3%, p < 0.005). A U-shaped relationship between a range of thyroid hormone levels (from hyper- to hypothyroid concentrations) and myocardial strains was observed. The clinical consequences of these findings remain to be determined but may point out an increased myocardial vulnerability even in states of moderate subclinical hyperthyroidism and short-term hypothyroidism.
Singh, Gautam K.; Cupps, Brian; Pasque, Michael; Woodard, Pamela K.; Holland, Mark R.; Ludomirsky, Achiau
2013-01-01
Background Myocardial strain is a sensitive measure of ventricular systolic function. Two-dimensional speckle-tracking echocardiography (2DSE) is an angle-independent method for strain measurement but has not been validated in pediatric subjects. We evaluated the accuracy and reproducibility of 2DSE-measured strain against reference tagged MRI-measured strain in pediatric subjects with normal hearts and those with single ventricle (SV) of left ventricle (LV) morphology s/p Fontan procedure. Methods Peak systolic circumferential (CS) and longitudinal (LS) strains in segments (n = 16) of LVs in age and BSA matched 20 healthy and 12 pediatric subjects with tricuspid atresia s/p Fontan procedure were measured by 2DSE and tagged MRI. Average (global) and regional segmental strains measured by two methods were compared using Spearman and Bland-Altman analyses. Results 2DSE and tagged MRI measured global strains demonstrated close agreements, which were better for LS than CS and in normal LVs than in SVs (95% limits of agreement: +0.0% to +3.12%, −2.48 % to +1.08%, −4.6% to +1.8% and −3.6% to +1.8% respectively). There was variability in agreement between regional strains with wider limits in apical than in basal regions in normal LVs and heterogeneous in SVs. The strain values were significantly (p < 0.05) higher in normal LVs than in SVs except for basal LSs, which were similar in both cohorts. The regional strains in normal LVs demonstrated an apico-basal magnitude gradient whereas SVs showed heterogeneity. The reproducibility was the most robust for images obtained with frame rates between 60 and 90 frame/sec; global LS in both cohorts; and basal strains in normal LVs. Conclusions 2DSE-measured strains agree with MRI-measured strain globally but vary regionally particularly in SVs. Global strain may be more robust tool for the cardiac function evaluation than regional strain in SV physiology. The reliability of 2DSE measured strain is affected by the frame rate, nature of strain, and ventricular geometry. PMID:20850945
NASA Astrophysics Data System (ADS)
Perillo, Evan P.; Liu, Yen-Liang; Huynh, Khang; Liu, Cong; Chou, Chao-Kai; Hung, Mien-Chie; Yeh, Hsin-Chih; Dunn, Andrew K.
2015-07-01
Molecular trafficking within cells, tissues and engineered three-dimensional multicellular models is critical to the understanding of the development and treatment of various diseases including cancer. However, current tracking methods are either confined to two dimensions or limited to an interrogation depth of ~15 μm. Here we present a three-dimensional tracking method capable of quantifying rapid molecular transport dynamics in highly scattering environments at depths up to 200 μm. The system has a response time of 1 ms with a temporal resolution down to 50 μs in high signal-to-noise conditions, and a spatial localization precision as good as 35 nm. Built on spatiotemporally multiplexed two-photon excitation, this approach requires only one detector for three-dimensional particle tracking and allows for two-photon, multicolour imaging. Here we demonstrate three-dimensional tracking of epidermal growth factor receptor complexes at a depth of ~100 μm in tumour spheroids.
Speckle field as a multiple particle trap
NASA Astrophysics Data System (ADS)
Shvedov, V. G.; Rode, A. V.; Izdebskaya, Ya. V.; Desyatnikov, A. S.; Krolikowski, W.; Kivshar, Yu. S.
2010-04-01
We demonstrate that a speckle pattern in the spatially coherent laser field transmitted by a diffuser forms a multitude of three-dimensional bottle-shaped micro-traps. These multiple traps serve as a means for an effective trapping of large number of air-born absorbing particles. Confinement of up to a few thousand particles in air with a single beam has been achieved. The ability to capture light-absorbing particles suspended in gases by optical means opens up rich and diverse practical opportunities, including development of photonic shielding/fencing for environmental protection in nanotechnology industry and new methods of touch-free air transport of particles and small containers, which may hold dangerous substances, or viruses and living cells.
Albright, B. J.; Yin, L.; Bowers, K. J.; ...
2016-03-04
Two- and three-dimensional particle-in-cell simulations of stimulated Brillouin scattering(SBS) in laser speckle geometry have been analyzed to evaluate the relative importance of competing nonlinear processes in the evolution and saturation of SBS. It is found that ion-trapping-induced wavefront bowing and breakup of ion acoustic waves(IAW) and the associated side-loss of trapped ions dominate electron-trapping-induced IAW wavefront bowing and breakup, as well as the two-ion-wave decay instability over a range of ZT e/T i conditions and incident laser intensities. In the simulations, the latter instability does not govern the nonlinear saturation of SBS; however, evidence of two-ion-wave decay is seen, appearingmore » as a modulation of the ion acoustic wavefronts. This modulation is periodic in the laser polarization plane, anti-symmetric across the speckle axis, and of a wavenumber matching that of the incident laser pulse. Furthermore, a simple analytic model is provided for how spatial “imprinting” from a high frequency inhomogeneity (in this case, the density modulation from the laser) in an unstable system with continuum eigenmodes can selectively amplify modes with wavenumbers that match that of the inhomogeneity.« less
Modeling envelope statistics of blood and myocardium for segmentation of echocardiographic images.
Nillesen, Maartje M; Lopata, Richard G P; Gerrits, Inge H; Kapusta, Livia; Thijssen, Johan M; de Korte, Chris L
2008-04-01
The objective of this study was to investigate the use of speckle statistics as a preprocessing step for segmentation of the myocardium in echocardiographic images. Three-dimensional (3D) and biplane image sequences of the left ventricle of two healthy children and one dog (beagle) were acquired. Pixel-based speckle statistics of manually segmented blood and myocardial regions were investigated by fitting various probability density functions (pdf). The statistics of heart muscle and blood could both be optimally modeled by a K-pdf or Gamma-pdf (Kolmogorov-Smirnov goodness-of-fit test). Scale and shape parameters of both distributions could differentiate between blood and myocardium. Local estimation of these parameters was used to obtain parametric images, where window size was related to speckle size (5 x 2 speckles). Moment-based and maximum-likelihood estimators were used. Scale parameters were still able to differentiate blood from myocardium; however, smoothing of edges of anatomical structures occurred. Estimation of the shape parameter required a larger window size, leading to unacceptable blurring. Using these parameters as an input for segmentation resulted in unreliable segmentation. Adaptive mean squares filtering was then introduced using the moment-based scale parameter (sigma(2)/mu) of the Gamma-pdf to automatically steer the two-dimensional (2D) local filtering process. This method adequately preserved sharpness of the edges. In conclusion, a trade-off between preservation of sharpness of edges and goodness-of-fit when estimating local shape and scale parameters is evident for parametric images. For this reason, adaptive filtering outperforms parametric imaging for the segmentation of echocardiographic images.
Chapman, Christopher A. R.; Ly, Sonny; Wang, Ling; ...
2016-03-02
Here we show the use of dynamic laser speckle autocorrelation spectroscopy in conjunction with the photothermal treatment of nanoporous gold (np-Au) thin films to probe nanoscale morphology changes during the photothermal treatment. Utilizing this spectroscopy method, backscattered speckle from the incident laser is tracked during photothermal treatment and both the characteristic feature size and annealing time of the film are determined. These results demonstrate that this method can successfully be used to monitor laser-based surface modification processes without the use of ex-situ characterization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chapman, Christopher A. R.; Ly, Sonny; Wang, Ling
Here we show the use of dynamic laser speckle autocorrelation spectroscopy in conjunction with the photothermal treatment of nanoporous gold (np-Au) thin films to probe nanoscale morphology changes during the photothermal treatment. Utilizing this spectroscopy method, backscattered speckle from the incident laser is tracked during photothermal treatment and both the characteristic feature size and annealing time of the film are determined. These results demonstrate that this method can successfully be used to monitor laser-based surface modification processes without the use of ex-situ characterization.
Application of laser speckle to randomized numerical linear algebra
NASA Astrophysics Data System (ADS)
Valley, George C.; Shaw, Thomas J.; Stapleton, Andrew D.; Scofield, Adam C.; Sefler, George A.; Johannson, Leif
2018-02-01
We propose and simulate integrated optical devices for accelerating numerical linear algebra (NLA) calculations. Data is modulated on chirped optical pulses and these propagate through a multimode waveguide where speckle provides the random projections needed for NLA dimensionality reduction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mawet, D.; Ruane, G.; Xuan, W.
2017-04-01
High-dispersion coronagraphy (HDC) optimally combines high-contrast imaging techniques such as adaptive optics/wavefront control plus coronagraphy to high spectral resolution spectroscopy. HDC is a critical pathway toward fully characterizing exoplanet atmospheres across a broad range of masses from giant gaseous planets down to Earth-like planets. In addition to determining the molecular composition of exoplanet atmospheres, HDC also enables Doppler mapping of atmosphere inhomogeneities (temperature, clouds, wind), as well as precise measurements of exoplanet rotational velocities. Here, we demonstrate an innovative concept for injecting the directly imaged planet light into a single-mode fiber, linking a high-contrast adaptively corrected coronagraph to a high-resolutionmore » spectrograph (diffraction-limited or not). Our laboratory demonstration includes three key milestones: close-to-theoretical injection efficiency, accurate pointing and tracking, and on-fiber coherent modulation and speckle nulling of spurious starlight signal coupling into the fiber. Using the extreme modal selectivity of single-mode fibers, we also demonstrated speckle suppression gains that outperform conventional image-based speckle nulling by at least two orders of magnitude.« less
NASA Astrophysics Data System (ADS)
Mawet, D.; Ruane, G.; Xuan, W.; Echeverri, D.; Klimovich, N.; Randolph, M.; Fucik, J.; Wallace, J. K.; Wang, J.; Vasisht, G.; Dekany, R.; Mennesson, B.; Choquet, E.; Delorme, J.-R.; Serabyn, E.
2017-04-01
High-dispersion coronagraphy (HDC) optimally combines high-contrast imaging techniques such as adaptive optics/wavefront control plus coronagraphy to high spectral resolution spectroscopy. HDC is a critical pathway toward fully characterizing exoplanet atmospheres across a broad range of masses from giant gaseous planets down to Earth-like planets. In addition to determining the molecular composition of exoplanet atmospheres, HDC also enables Doppler mapping of atmosphere inhomogeneities (temperature, clouds, wind), as well as precise measurements of exoplanet rotational velocities. Here, we demonstrate an innovative concept for injecting the directly imaged planet light into a single-mode fiber, linking a high-contrast adaptively corrected coronagraph to a high-resolution spectrograph (diffraction-limited or not). Our laboratory demonstration includes three key milestones: close-to-theoretical injection efficiency, accurate pointing and tracking, and on-fiber coherent modulation and speckle nulling of spurious starlight signal coupling into the fiber. Using the extreme modal selectivity of single-mode fibers, we also demonstrated speckle suppression gains that outperform conventional image-based speckle nulling by at least two orders of magnitude.
Lee, KyeoReh; Park, YongKeun
2016-01-01
The word ‘holography' means a drawing that contains all of the information for light—both amplitude and wavefront. However, because of the insufficient bandwidth of current electronics, the direct measurement of the wavefront of light has not yet been achieved. Though reference-field-assisted interferometric methods have been utilized in numerous applications, introducing a reference field raises several fundamental and practical issues. Here we demonstrate a reference-free holographic image sensor. To achieve this, we propose a speckle-correlation scattering matrix approach; light-field information passing through a thin disordered layer is recorded and retrieved from a single-shot recording of speckle intensity patterns. Self-interference via diffusive scattering enables access to impinging light-field information, when light transport in the diffusive layer is precisely calibrated. As a proof-of-concept, we demonstrate direct holographic measurements of three-dimensional optical fields using a compact device consisting of a regular image sensor and a diffusor. PMID:27796290
Lee, KyeoReh; Park, YongKeun
2016-10-31
The word 'holography' means a drawing that contains all of the information for light-both amplitude and wavefront. However, because of the insufficient bandwidth of current electronics, the direct measurement of the wavefront of light has not yet been achieved. Though reference-field-assisted interferometric methods have been utilized in numerous applications, introducing a reference field raises several fundamental and practical issues. Here we demonstrate a reference-free holographic image sensor. To achieve this, we propose a speckle-correlation scattering matrix approach; light-field information passing through a thin disordered layer is recorded and retrieved from a single-shot recording of speckle intensity patterns. Self-interference via diffusive scattering enables access to impinging light-field information, when light transport in the diffusive layer is precisely calibrated. As a proof-of-concept, we demonstrate direct holographic measurements of three-dimensional optical fields using a compact device consisting of a regular image sensor and a diffusor.
Armstrong, Anderson C.; Ricketts, Erin P.; Cox, Christopher; Adler, Paul; Arynchyn, Alexander; Liu, Kiang; Stengel, Ellen; RDCS; Sidney, Stephen; Lewis, Cora E.; Schreiner, Pamela J.; Shikany, James M.; Keck, Kimberly; Merlo, Jamie; Gidding, Samuel S.; Lima, João A. C.
2014-01-01
Introduction Few large studies describe quality control procedures and reproducibility findings in cardiovascular ultra-sound, particularly in novel techniques such as Speckle Tracking (STE). We evaluate the echocardiography assessment performance in the CARDIA study Y25 examination (2010-2011) and report findings from a quality control and reproducibility program conducted to assess Field Center image acquisition and Reading Center (RC) accuracy. Methods The CARDIA Y25 examination had 3,475 echocardiograms performed in 4 US Field Centers and analyzed in a Reading Center, assessing standard echocardiography (LA dimension, aortic root, LV mass, LV end-diastolic volume [LVEDV], ejection fraction [LVEF]), and STE (2- and 4-chamber longitudinal, circumferential, and radial strains). Reproducibility was assessed using intra-class correlation coefficients (ICC), coefficients of variation (CV), and Bland-Altman plots. Results For standard echocardiography reproducibility, LV mass and LVEDV consistently had CV above 10% and aortic root below 6%. Intra-sonographer aortic root and LV mass had the most robust values of ICC in standard echocardiography. For STE, the number of properly tracking segments was above 80% in short-axis and 4-chamber and 58% in 2-chamber. Longitudinal strain parameters were the most robust and radial strain showed the highest variation. Comparing Field Centers with Echo RC STE readings, mean differences ranged from 0.4% to 4.1% and ICC from 0.37 to 0.66, with robust results for longitudinal strains. Conclusion Echocardiography image acquisition and reading processes in the CARDIA study were highly reproducible, including robust results for STE analysis. Consistent quality control may increase the reliability of echocardiography measurements in large cohort studies. PMID:25382818
Armstrong, Anderson C; Ricketts, Erin P; Cox, Christopher; Adler, Paul; Arynchyn, Alexander; Liu, Kiang; Stengel, Ellen; Sidney, Stephen; Lewis, Cora E; Schreiner, Pamela J; Shikany, James M; Keck, Kimberly; Merlo, Jamie; Gidding, Samuel S; Lima, João A C
2015-08-01
Few large studies describe quality control procedures and reproducibility findings in cardiovascular ultrasound, particularly in novel techniques such as speckle tracking echocardiography (STE). We evaluate the echocardiography assessment performance in the Coronary Artery Risk Development in Young Adults (CARDIA) study Year 25 (Y25) examination (2010-2011) and report findings from a quality control and reproducibility program conducted to assess Field Center image acquisition and reading center (RC) accuracy. The CARDIA Y25 examination had 3475 echocardiograms performed in 4 US Field Centers and analyzed in a RC, assessing standard echocardiography (LA dimension, aortic root, LV mass, LV end-diastolic volume [LVEDV], ejection fraction [LVEF]), and STE (two- and four-chamber longitudinal, circumferential, and radial strains). Reproducibility was assessed using intraclass correlation coefficients (ICC), coefficients of variation (CV), and Bland-Altman plots. For standard echocardiography reproducibility, LV mass and LVEDV consistently had CV above 10% and aortic root below 6%. Intra-sonographer aortic root and LV mass had the most robust values of ICC in standard echocardiography. For STE, the number of properly tracking segments was above 80% in short-axis and four-chamber and 58% in two-chamber views. Longitudinal strain parameters were the most robust and radial strain showed the highest variation. Comparing Field Centers with echocardiography RC STE readings, mean differences ranged from 0.4% to 4.1% and ICC from 0.37 to 0.66, with robust results for longitudinal strains. Echocardiography image acquisition and reading processes in the CARDIA study were highly reproducible, including robust results for STE analysis. Consistent quality control may increase the reliability of echocardiography measurements in large cohort studies. © 2014, Wiley Periodicals, Inc.
Prospective comparison of speckle tracking longitudinal bidimensional strain between two vendors.
Castel, Anne-Laure; Szymanski, Catherine; Delelis, François; Levy, Franck; Menet, Aymeric; Mailliet, Amandine; Marotte, Nathalie; Graux, Pierre; Tribouilloy, Christophe; Maréchaux, Sylvestre
2014-02-01
Speckle tracking is a relatively new, largely angle-independent technique used for the evaluation of myocardial longitudinal strain (LS). However, significant differences have been reported between LS values obtained by speckle tracking with the first generation of software products. To compare LS values obtained with the most recently released equipment from two manufacturers. Systematic scanning with head-to-head acquisition with no modification of the patient's position was performed in 64 patients with equipment from two different manufacturers, with subsequent off-line post-processing for speckle tracking LS assessment (Philips QLAB 9.0 and General Electric [GE] EchoPAC BT12). The interobserver variability of each software product was tested on a randomly selected set of 20 echocardiograms from the study population. GE and Philips interobserver coefficients of variation (CVs) for global LS (GLS) were 6.63% and 5.87%, respectively, indicating good reproducibility. Reproducibility was very variable for regional and segmental LS values, with CVs ranging from 7.58% to 49.21% with both software products. The concordance correlation coefficient (CCC) between GLS values was high at 0.95, indicating substantial agreement between the two methods. While good agreement was observed between midwall and apical regional strains with the two software products, basal regional strains were poorly correlated. The agreement between the two software products at a segmental level was very variable; the highest correlation was obtained for the apical cap (CCC 0.90) and the poorest for basal segments (CCC range 0.31-0.56). A high level of agreement and reproducibility for global but not for basal regional or segmental LS was found with two vendor-dependent software products. This finding may help to reinforce clinical acceptance of GLS in everyday clinical practice. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Chowdhury, Shahryar M.; Hijazi, Ziyad M.; Rhodes, John F.; Kar, Saibal; Makkar, Raj; Mullen, Michael; Cao, Qi-Ling; Mandinov, Lazar; Buckley, Jason; Pietris, Nicholas P.; Shirali, Girish S.
2015-01-01
Background Patients with free pulmonary regurgitation or mixed pulmonary stenosis and regurgitation and severely dilated right ventricles (RV) show little improvement in ventricular function after pulmonary valve replacement when assessed by traditional echocardiographic markers. We evaluated changes in right and left ventricular (LV) function using speckle tracking echocardiography in patients after SAPIEN transcatheter pulmonary valve (TPV) placement. Methods Echocardiograms were evaluated at baseline, discharge, 1 and 6 months after TPV placement in 24 patients from 4 centers. Speckle tracking measures of function included peak longitudinal strain, strain rate, and early diastolic strain rate. RV fractional area change, tricuspid annular plane systolic excursion, and left ventricular LV ejection fraction were assessed. Routine Doppler and tissue Doppler velocities were measured. Results At baseline, all patients demonstrated moderate to severe pulmonary regurgitation; this improved following TPV placement. No significant changes were detected in conventional measures of RV or LV function at 6 months. RV longitudinal strain (−16.9% vs. −19.6%, P < 0.01), strain rate (−0.87 s−1 vs. −1.16 s−1, P = 0.01), and LV longitudinal strain (−16.2% vs. −18.2%, P = 0.01) improved between baseline and 6 month follow-up. RV early diastolic strain rate, LV longitudinal strain rate and early diastolic strain rate showed no change. Conclusion Improvements in RV longitudinal strain, strain rate, and LV longitudinal strain are seen at 6 months post-TPV. Diastolic function does not appear to change at 6 months. Speckle tracking echocardiography may be more sensitive than traditional measures in detecting changes in systolic function after TPV implantation. (Echocardiography 2015;32:461–469) PMID:25047063
Pedro, B; Stephenson, H; Linney, C; Cripps, P; Dukes-McEwan, J
2017-08-01
Assess global circumferential and radial systolic and diastolic myocardial function with speckle tracking echocardiography (STE) in healthy Great Danes (GD) and in GD diagnosed with dilated cardiomyopathy (DCM). Eighty-nine GD were included in the study: 39 healthy (normal group [NORMg]) and 50 diagnosed with DCM (DCMg). This was a retrospective study. Signalment and echocardiographic diagnosis were obtained from the medical records of GD assessed between 2008 and 2012. Speckle tracking echocardiography analysis of circumferential (C) and radial (R) strain (St) and strain rate (SR) in systole (S), early (E) and late (A) diastole was performed at the levels of the mitral valve (MV), papillary muscles (PM) and apex (Ap) of the left ventricle. Univariable and multivariable analysis was performed to identify differences between groups. Speckle tracking echocardiography variables increase from the MV towards the Ap of the left ventricle in both NORMg and DCMg dogs, some reaching statistical significance. Most of the variables (28/31) were lower in DCMg than in NORMg dogs: statistically significant variables included radial SR at the Ap in systole (p=0.029), radial strain at the PM (p=0.012), circumferential SR at the PM in systole (p=0.031), circumferential and radial SR at the MV in early diastole (p=0.019 and p=0.049, respectively). There are significant differences in STE variables between NORMg and DCMg Great Danes, although the overlap between the two groups may indicate that these variables are not sufficiently discriminatory. STE variables are not sufficiently sensitive to use in isolation as a screening method. Copyright © 2017 Elsevier B.V. All rights reserved.
Corîci, Oana Maria; Tănasie, Cornelia Andreea; Alexandru, Dragoş Ovidiu; Florescu, Mihaela Corina; Comănescu, Maria Victoria; Kamal, Kamal Constantin; Ţenea-Cojan, Tiberiu Ştefăniţă; Iancău, Maria; Dinescu, Sorin Nicolae
2018-01-01
To assess left ventricular (LV) systolic function and morphology in patients with severe dilated cardiomyopathy (DCM), using both conventional and a complex technique, speckle-tracking echocardiography, and evaluate the correlation between pre-ejection period and left ventricular ejection period (PEP/LVET) ratio, global longitudinal strain (GLS), and severity of the condition. Seventeen patients were enrolled after rigorous criteria. Echocardiography was performed in conventional and speckle-tracking mode, in all patients with DCM, in sinus rhythm. LV dimensions, volumes and ejection fraction (LVEF) were measured. PEP/LVET ratio was obtained from apical 5-chamber axis and was defined as the time between QRS onset and LV ejection reported to LV ejection period. Speckle-tracking imaging was performed in offline mode and GLS was obtained from parasternal 4-, 3-, 2-chamber apical view, by averaging longitudinal peak systolic strain of all 17 LV-segments. New York Heart Association (NYHA) functional class correlated significantly with LVEF (-0.82; p=0.0006), PEP/LVET (0.86; p=0.001) or GLS (0.85; p=0.0002). Considerable correlations were between mitral regurgitation (MR) severity and LVEF (-0.65; p=0.01) or PEP/LVET (0.69; p=0.0059), but higher were between MR severity and GLS (0.76; p=0.0018). Tricuspid regurgitation (TR) grading correlated statistically with LVEF (-0.62; p=0.01), PEP/LVET and GLS (0.6; p=0.018; and 0.62; p=0.014, respectively). As opposed to the parameters in conventional echocardiography, GLS correlated with DCM etiology (p=0.0046) and with the gender (p=0.048). This study demonstrates that, in patients with DCM, assessment of cardiac dyssynchrony can be accurately accomplished by combining parameters in conventional and in speckle-tracking echocardiography.
Three-Dimensional Visualization of Particle Tracks.
ERIC Educational Resources Information Center
Julian, Glenn M.
1993-01-01
Suggests ways to bring home to the introductory physics student some of the excitement of recent discoveries in particle physics. Describes particle detectors and encourages the use of the Standard Model along with real images of particle tracks to determine three-dimensional views of tracks. (MVL)
Obokata, Masaru; Nagata, Yasufumi; Wu, Victor Chien-Chia; Kado, Yuichiro; Kurabayashi, Masahiko; Otsuji, Yutaka; Takeuchi, Masaaki
2016-05-01
Cardiac magnetic resonance (CMR) feature tracking (FT) with steady-state free precession (SSFP) has advantages over traditional myocardial tagging to analyse left ventricular (LV) strain. However, direct comparisons of CMRFT and 2D/3D echocardiography speckle tracking (2/3DEST) for measurement of LV strain are limited. The aim of this study was to investigate the feasibility and reliability of CMRFT and 2D/3DEST for measurement of global LV strain. We enrolled 106 patients who agreed to undergo both CMR and 2D/3DE on the same day. SSFP images at multiple short-axis and three apical views were acquired. 2DE images from three levels of short-axis, three apical views, and 3D full-volume datasets were also acquired. Strain data were expressed as absolute values. Feasibility was highest in CMRFT, followed by 2DEST and 3DEST. Analysis time was shortest in 3DEST, followed by CMRFT and 2DEST. There was good global longitudinal strain (GLS) correlation between CMRFT and 2D/3DEST (r = 0.83 and 0.87, respectively) with the limit of agreement (LOA) ranged from ±3.6 to ±4.9%. Excellent global circumferential strain (GCS) correlation between CMRFT and 2D/3DEST was observed (r = 0.90 and 0.88) with LOA of ±6.8-8.5%. Global radial strain showed fair correlations (r = 0.69 and 0.82, respectively) with LOA ranged from ±12.4 to ±16.3%. CMRFT GCS showed least observer variability with highest intra-class correlation. Although not interchangeable, the high GLS and GCS correlation between CMRFT and 2D/3DEST makes CMRFT a useful modality for quantification of global LV strain in patients, especially those with suboptimal echo image quality. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Development of three-dimensional tracking system using astigmatic lens method for microscopes
NASA Astrophysics Data System (ADS)
Kibata, Hiroki; Ishii, Katsuhiro
2017-07-01
We have developed a three-dimensional tracking system for microscopes. Using the astigmatic lens method and a CMOS image sensor, we realize a rapid detection of a target position in a wide range. We demonstrate a target tracking using the developed system.
NASA Astrophysics Data System (ADS)
Ma, Ning; Zhao, Juan; Hanson, Steen G.; Takeda, Mitsuo; Wang, Wei
2016-10-01
Laser speckle has received extensive studies of its basic properties and associated applications. In the majority of research on speckle phenomena, the random optical field has been treated as a scalar optical field, and the main interest has been concentrated on their statistical properties and applications of its intensity distribution. Recently, statistical properties of random electric vector fields referred to as Polarization Speckle have come to attract new interest because of their importance in a variety of areas with practical applications such as biomedical optics and optical metrology. Statistical phenomena of random electric vector fields have close relevance to the theories of speckles, polarization and coherence theory. In this paper, we investigate the correlation tensor for stochastic electromagnetic fields modulated by a depolarizer consisting of a rough-surfaced retardation plate. Under the assumption that the microstructure of the scattering surface on the depolarizer is as fine as to be unresolvable in our observation region, we have derived a relationship between the polarization matrix/coherency matrix for the modulated electric fields behind the rough-surfaced retardation plate and the coherence matrix under the free space geometry. This relation is regarded as entirely analogous to the van Cittert-Zernike theorem of classical coherence theory. Within the paraxial approximation as represented by the ABCD-matrix formalism, the three-dimensional structure of the generated polarization speckle is investigated based on the correlation tensor, indicating a typical carrot structure with a much longer axial dimension than the extent in its transverse dimension.
Future Perspectives for Management of Stage A Heart Failure.
Tanaka, Hidekazu
2018-05-07
Patients with Stage A heart failure (HF) show no HF symptoms but have related comorbid diseases with a high risk of progressing to HF. Screening for comorbid diseases warrants closer attention because of the growing interest in addressing Stage A HF as the best means of preventing eventual progression to overt HF such as Stages C and D. The identification of individuals of Stage A HF is potentially useful for the implementation of HF-prevention strategies; however, not all Stage A HF patients develop left ventricular (LV) structural heart disease or symptomatic HF, which lead to advanced HF stages. Therefore, Stage A HF requires management with the long-term goal of avoiding HF development; likewise, Stage B HF patients are ideal targets for HF prevention. Although the early detection of subclinical LV dysfunction is, thus, essential for delaying the progression to HF, the assessment of subclinical LV dysfunction can be challenging. Global longitudinal strain (GLS) as assessed by speckle-tracking echocardiography has recently been reported to be a sensitive marker of early subtle LV myocardial abnormalities, helpful for the prediction of the outcomes for various cardiac diseases, and superior to conventional echocardiographic indices. GLS reflects LV longitudinal myocardial systolic function, and can be assessed usually by means of two-dimensional speckle-tracking. This article reviews the importance of the assessment of subclinical LV dysfunction in Stage A HF patients by means of GLS, and its current potential to prevent progression to later stage HF.
Sengupta, Shantanu P.; Jaju, Rahul; Nugurwar, Abhijeet; Caracciolo, Giuseppe; Sengupta, Partho P.
2012-01-01
Background The status of left ventricle in sickle cell anemia presenting in sickle crisis and follow up has been minimally studied in past. To determine the left ventricular (LV) myocardial performance in these patients, we performed the study to assess two dimensional strains imaging which allowed a rapid and an accurate analysis of global and regional LV myocardial performance in longitudinal, radial, and circumferential directions. Methods In this prospective study, 2-dimensional echocardiography (2DE) images of the LV were obtained in 52 subjects which included 32 patients (23 ± 8yrs, 16 male) with homozygous sickle cell anemia (SCA) in sickle cell crisis and 20 healthy controls (23 ± 5 yrs, 11 male) using apical 4-chamber and parasternal short-axis at the basal, mid, and apical levels. Of these 32 patients, 2DE was performed again in 18 patients in follow up (8 months ± 5 days). Longitudinal, circumferential and radial strains (LS, CS and RS respectively) were quantified and compared in an 18-segment model using a novel speckle tracking system (2D Cardiac Performance Analysis, TomTec Imaging System, Munich, Germany). Results There was no significant difference in LV ejection fraction between both the groups (59.32 ± 12.6 vs. 52.3 ± 7.9; p-value > 0.05). In comparison with normal controls and follow up of sickle cell patients, peak LS was significantly attenuated in the subendocardial and subepicardial regions during sickle cell crisis (p < 0.05). However, a significant reduction in circumferential strain was evident only in subepicardial region (p < 0.001). Also patients in sickle cell crisis showed significantly higher radial strain parameters than controls (p < 0.001). Conclusion Patients with SCA presenting in sickle cell crisis have reduced longitudinal shortening. LV myocardial performance remains unaltered due to relatively preserved circumferential shortening and increased radial thickening. PMID:23253406
Piccinino, Cristina; Giubertoni, Ailia; Zanaboni, Jacopo; Gravellone, Miriam; Sola, Daniele; Rosso, Roberta; Ferrarotti, Lorena; Marino, Paolo Nicola
2017-11-01
Increased right atrial size is related to adverse prognosis in pulmonary hypertension. The potential incremental value of right atrial function assessment is still unclear. We tested the relationship between right atrial two-dimensional speckle-tracking echocardiography impairment and hemodynamic, functional and clinical deterioration in patients with pulmonary hypertension. We prospectively evaluated 36 patients (27 female, 9 male; mean age 68 ± 13 years) with suspected pulmonary hypertension undergoing right heart catheterization and 16 matched controls. All patients underwent baseline evaluation by New York Heart Association functional class, 6-min walking test, brain natriuretic peptide (BNP), and standard two-dimensional echocardiography in less than 48 h of right heart catheterization. Right atrial two-dimensional speckle-tracking echocardiography was assessed by averaging all segments in standard four-chamber apical view. Right atrial global integral strain was significantly lower in patients compared with controls (11.40 ± 5.22% vs. 25.72 ± 5.95 P < 0.001). Moreover, right atrial global strain, but not right atrial area or volume, was correlated with invasively measured cardiac index (CI) (r = 0.72; P < 0.0001) and pulmonary vascular resistances in all patients, even though stronger in subjects with precapillary pulmonary hypertension (r = -0.42, P = 0.018; r = -0.54, P = 0.007 respectively; P = 0.007). It was also correlated with New York Heart Association (P = 0.027), BNP (P = 0.002), and 6-min walking test (P = 0.006). After multivariate analysis including right atrial volume, tricuspid annular plane systolic excursion, left atrial strain, and BNP, right atrial global strain showed the strongest correlation with CI. Area under the curve optimal cutoff for predicting CI at least 2.4 l/min/m was 17% (area under the curve: 0.83, sensitivity: 90%, specificity: 54%). Right atrial global strain can identify right atrial functional impairment before structural changes and may be implemented in a comprehensive, noninvasive right heart assessment for diagnosis and follow-up of pulmonary hypertension patients.
Optically Phase-Locked Electronic Speckle Pattern Interferometer (OPL-ESPI)
NASA Astrophysics Data System (ADS)
Moran, Steven E.; Law, Robert L.; Craig, Peter N.; Goldberg, Warren M.
1986-10-01
This report describes the design, theory, operation, and characteristics of the OPL-ESPI, which generates real time equal Doppler speckle contours of vibrating objects from unstable sensor platforms with a Doppler resolution of 30 Hz and a maximum tracking range of + or - 5 HMz. The optical phase locked loop compensates for the deleterious effects of ambient background vibration and provides the bases for a new ESPI video signal processing technique, which produces high contrast speckle contours. The OPL-ESPI system has local oscillator phase modulation capability, offering the potential for detection of vibrations with the amplitudes less than lambda/100.
Digital Correlation In Laser-Speckle Velocimetry
NASA Technical Reports Server (NTRS)
Gilbert, John A.; Mathys, Donald R.
1992-01-01
Periodic recording helps to eliminate spurious results. Improved digital-correlation process extracts velocity field of two-dimensional flow from laser-speckle images of seed particles distributed sparsely in flow. Method which involves digital correlation of images recorded at unequal intervals, completely automated and has potential to be fastest yet.
In vivo burn diagnosis by camera-phone diffuse reflectance laser speckle detection.
Ragol, S; Remer, I; Shoham, Y; Hazan, S; Willenz, U; Sinelnikov, I; Dronov, V; Rosenberg, L; Bilenca, A
2016-01-01
Burn diagnosis using laser speckle light typically employs widefield illumination of the burn region to produce two-dimensional speckle patterns from light backscattered from the entire irradiated tissue volume. Analysis of speckle contrast in these time-integrated patterns can then provide information on burn severity. Here, by contrast, we use point illumination to generate diffuse reflectance laser speckle patterns of the burn. By examining spatiotemporal fluctuations in these time-integrated patterns along the radial direction from the incident point beam, we show the ability to distinguish partial-thickness burns in a porcine model in vivo within the first 24 hours post-burn. Furthermore, our findings suggest that time-integrated diffuse reflectance laser speckle can be useful for monitoring burn healing over time post-burn. Unlike conventional diffuse reflectance laser speckle detection systems that utilize scientific or industrial-grade cameras, our system is designed with a camera-phone, demonstrating the potential for burn diagnosis with a simple imager.
In vivo burn diagnosis by camera-phone diffuse reflectance laser speckle detection
Ragol, S.; Remer, I.; Shoham, Y.; Hazan, S.; Willenz, U.; Sinelnikov, I.; Dronov, V.; Rosenberg, L.; Bilenca, A.
2015-01-01
Burn diagnosis using laser speckle light typically employs widefield illumination of the burn region to produce two-dimensional speckle patterns from light backscattered from the entire irradiated tissue volume. Analysis of speckle contrast in these time-integrated patterns can then provide information on burn severity. Here, by contrast, we use point illumination to generate diffuse reflectance laser speckle patterns of the burn. By examining spatiotemporal fluctuations in these time-integrated patterns along the radial direction from the incident point beam, we show the ability to distinguish partial-thickness burns in a porcine model in vivo within the first 24 hours post-burn. Furthermore, our findings suggest that time-integrated diffuse reflectance laser speckle can be useful for monitoring burn healing over time post-burn. Unlike conventional diffuse reflectance laser speckle detection systems that utilize scientific or industrial-grade cameras, our system is designed with a camera-phone, demonstrating the potential for burn diagnosis with a simple imager. PMID:26819831
NASA Technical Reports Server (NTRS)
Breckinridge, Jim B. (Editor)
1990-01-01
Attention is given to such topics as ground interferometers, space interferometers, speckle-based and interferometry-based astronomical observations, adaptive and atmospheric optics, speckle techniques, and instrumentation. Particular papers are presented concerning recent progress on the IR Michelson array; the IOTA interferometer project; a space interferometer concept for the detection of extrasolar earth-like planets; IR speckle imaging at Palomar; optical diameters of stars measured with the Mt. Wilson Mark III interferometer; the IR array camera for interferometry with the cophased Multiple Mirror Telescope; optimization techniques appliesd to the bispectrum of one-dimensional IR astronomical speckle data; and adaptive optical iamging for extended objects.
Estimation of three-dimensional radar tracking using modified extended kalman filter
NASA Astrophysics Data System (ADS)
Aditya, Prima; Apriliani, Erna; Khusnul Arif, Didik; Baihaqi, Komar
2018-03-01
Kalman filter is an estimation method by combining data and mathematical models then developed be extended Kalman filter to handle nonlinear systems. Three-dimensional radar tracking is one of example of nonlinear system. In this paper developed a modification method of extended Kalman filter from the direct decline of the three-dimensional radar tracking case. The development of this filter algorithm can solve the three-dimensional radar measurements in the case proposed in this case the target measured by radar with distance r, azimuth angle θ, and the elevation angle ϕ. Artificial covariance and mean adjusted directly on the three-dimensional radar system. Simulations result show that the proposed formulation is effective in the calculation of nonlinear measurement compared with extended Kalman filter with the value error at 0.77% until 1.15%.
Spriestersbach, Hendrik; Oh-Icí, Darach; Schmitt, Boris; Berger, Felix; Schmitz, Lothar
2015-01-01
There are significant variations in the published normal values of two-dimensional speckle tracking-derived strain and strain rate. These occur even when authors use the same software. To measure strain, the operator creates a region of interest (ROI) to define the myocardium to be analyzed. The purpose of this study was to test the hypothesis that measurements vary significantly with the chosen ROI width. In 20 healthy subjects (11 males, mean age 17.6 ± 6.18 years) an apical four-chamber view (4CH) and parasternal short-axis view (SAX) were analyzed. Initially ROI width was set automatically by the software. Two subsequent measurements were obtained from each cine loop by choosing the ROI width one step narrower and one step wider than the automatic ROI width. The mean differences between the measurements of narrower and automatic ROI and between automatic and wider ROI were -1.8 ± 0.7% and -0.9 ± 0.5% for global longitudinal strain (SL), -2.2 ± 0.6% and -1.7 ± 0.7% for global circumferential strain (SC), -0.10 ± 0.06/sec and -0.07 ± 0.06/sec for global longitudinal strain rate (SrL), and -0.15 ± 0.09/sec and -0.12 ± 0.07/sec for global circumferential strain rate (SrC) (all P < 0.000). This corresponds to a relative difference to the mean of both measurements of -4.4 to -11.0%. Layer-specific myocardial deformation and curvature dependency lead to an inverse correlation between the chosen ROI width and strain and strain rate measurements. Just one step of ROI-width change leads to a significant bias. Precise ROI-width definition is essential but technical factors limit its feasibility. © 2014, Wiley Periodicals, Inc.
Hassanin, Noha; Alkemary, Alkhateeb
2016-04-01
Overhydration has a deleterious effect on cardio myocytes. This study was designated to evaluate left ventricular (LV) systolic and diastolic dysfunction in patients with various stages of chronic kidney disease (CKD) using conventional, tissue Doppler and two-dimensional speckle tracking echocardiography (2DSTE). Forty controls and 90 CKD patients, aged 49.3 ± 14 years old, were enrolled in the study. Patients were divided into 3 groups depending on their glomerular filtration rate. Group 1 (≥60 mL/min per 1.73 m(2) ), group 2 (≤60 mL/min per 1.73 m(2) ), and group 3 (≤60 mL/min per 1.73 m(2) and on regular dialysis for at least 12 months). Pulsed-Doppler and tissue Doppler studies were used to estimate LV filling pressure E/E'. Using 2DSTE, circumferential, radial, and longitudinal functions of the LV have been measured. LV longitudinal systolic strain, early, and late diastolic strain rates were significantly reduced in CKD patients (-16.9 ± 3.8%, 1.6 ± 0.5%, and 1.3 ± 0.4% in CKD vs. -22.5 ± 0.6%, 2.3 ± 0.2%, and 1.9 ± 0.1% in controls, P < 0.001 for all), and no difference was observed in terms of the circumferential LV functions (-22.4 ± 1.7 vs. -22.5 ± 1.4, P = 0.567). Severity of the kidney dysfunction appears to parallel with the rise of E/E' significantly (P < 0.001). In CKD, although the longitudinal and radial systolic functions were reduced, LV ejection fraction may remain within normal limits due to the preservation of the circumferential functions. Early detection of uremic cardiomyopathy might provide useful information for the risk stratification and decide the proper dialysis therapy in these patients. © 2015, Wiley Periodicals, Inc.
Baron Toaldo, M; Romito, G; Guglielmini, C; Diana, A; Pelle, N G; Contiero, B; Cipone, M
2017-05-01
The assessment of left atrial (LA) function by 2-dimensional speckle tracking echocardiography (STE) holds important clinical implications in human medicine. Few similar data are available in dogs. To assess LA function by STE in dogs with and without myxomatous mitral valve disease (MMVD), analyzing LA areas, systolic function, and strain. One hundred and fifty dogs were divided according to the American College of Veterinary Internal Medicine classification of heart failure: 23 dogs in class A, 52 in class B1, 36 in class B2, and 39 in class C + D. Prospective observational study. Conventional morphologic and Doppler variables, LA areas, and STE-based LA strain analysis were performed in all dogs and results were compared among groups. Correlation analysis was carried out between LA STE variables and other echocardiographic variables. Variability study showed good reproducibility for all the tested variables (coefficient of variation <16%). Left atrial areas, fractional area change, peak atrial longitudinal strain (PALS), peak atrial contraction strain, and contraction strain index (CSI) differed significantly between groups B2 and C + D and all the other groups (overall P < .001), whereas only PALS differed between groups B1 and A (P = .01). Left atrial areas increased with progression of the disease, whereas LA functional parameters decreased. Only CSI increased nonsignificantly from group A to group B1 and then progressively decreased. Thirty-one significant correlations (P < .001, r > .3) were found between conventional left heart echocardiographic variables and LA areas and strain variables. Left atrial STE analysis provides useful information on atrial function in the dog, highlighting a progressive decline in atrial function with worsening of MMVD. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Sengupta, Shantanu P; Bansal, Manish; Hofstra, Leonard; Sengupta, Partho P; Narula, Jagat
2017-01-01
The goal of this study was to evaluate the impact of pregnancy and labor on left ventricular (LV) myocardial mechanics using speckle tracking echocardiography (STE). Pregnancy is characterized by profound hormonal and hemodynamic alterations that directly or indirectly influence cardiac structure and function. However, the impact of these changes on left ventricular (LV) myocardial contractile function has not been fully elucidated. In this prospective, longitudinal study, 35 pregnant women underwent serial clinical and echocardiographic evaluation during each trimester and at labor. Two dimensional STE was performed to measure global LV longitudinal, circumferential and radial strain (GLS, GCS and GRS, respectively). Similar data obtained from 20 nulliparous, age-matched women were used as control. All strain values during pregnancy were adjusted for age and hemodynamic parameters. There was a progressive increase in heart rate, systolic and diastolic blood pressure, cardiac output and LV stroke-work during pregnancy. LV end-diastolic and end-systolic volumes also increased progressively but LV ejection fraction remained unaltered, except for slight reduction during the second trimester. Compared to the controls, GLS and GCS were reduced in the first trimester itself (GLS -22.39 ± 5.43 % vs. -18.66 ± 0.64 %, P 0.0002; GCS -20.84 ± 3.20 vs. -17.88 ± 0.09, P < 0.001) and remained so throughout the pregnancy and labor. In contrast, GRS showed an increase during pregnancy which peaked during the second trimester (24.18 ± 0.39 % vs. 18.06 ± 8.14 % in controls, P < 0.001). Alterations in loading conditions during pregnancy are associated with counterbalancing changes in the myocardial mechanics. LV longitudinal and circumferential strain are reduced whereas radial strain is increased. These counterbalancing changes serve to maintain overall LV ejection performance within a normal range and enable the maternal heart to meet the hemodynamic demands of pregnancy and labor.
Infrared Speckle Interferometry with 2-D Arrays
NASA Technical Reports Server (NTRS)
Harvey, P. M.; Balkum, S. L.; Monin, J. L.
1994-01-01
We describe results from a program of speckle interferometry with two-dimensional infrared array detectors. Analysis of observations of eta Carinae made with 58 x 62 InSb detector are discussed. The data have been analyzed with both the Labeyrie autocorrelation, a deconvolution of shift-and-add data, and a phase restoration process. Development of a new camera based on a much lower noise HgCdTe detector will lead to a significant improvement i limiting magnitude for IR speckle interferometry.
Evaluating platelet aggregation dynamics from laser speckle fluctuations.
Hajjarian, Zeinab; Tshikudi, Diane M; Nadkarni, Seemantini K
2017-07-01
Platelets are key to maintaining hemostasis and impaired platelet aggregation could lead to hemorrhage or thrombosis. We report a new approach that exploits laser speckle intensity fluctuations, emanated from a drop of platelet-rich-plasma (PRP), to profile aggregation. Speckle fluctuation rate is quantified by the speckle intensity autocorrelation, g 2 (t) , from which the aggregate size is deduced. We first apply this approach to evaluate polystyrene bead aggregation, triggered by salt. Next, we assess dose-dependent platelet aggregation and inhibition in human PRP spiked with adenosine diphosphate and clopidogrel. Additional spatio-temporal speckle analyses yield 2-dimensional maps of particle displacements to visualize platelet aggregate foci within minutes and quantify aggregation dynamics. These findings demonstrate the unique opportunity for assessing platelet health within minutes for diagnosing bleeding disorders and monitoring anti-platelet therapies.
Vallabhajosyula, Saraschandra; Rayes, Hamza A; Sakhuja, Ankit; Murad, Mohammad Hassan; Geske, Jeffrey B; Jentzer, Jacob C
2018-01-01
The data on speckle-tracking echocardiography (STE) in patients with sepsis are limited. This systematic review from 1975 to 2016 included studies in adults and children evaluating cardiovascular dysfunction in sepsis, severe sepsis, and septic shock utilizing STE for systolic global longitudinal strain (GLS). The primary outcome was short- or long-term mortality. Given the significant methodological and statistical differences between published studies, combining the data using meta-analysis methods was not appropriate. A total of 120 studies were identified, with 5 studies (561 patients) included in the final analysis. All studies were prospective observational studies using the 2001 criteria for defining sepsis. Three studies demonstrated worse systolic GLS to be associated with higher mortality, whereas 2 did not show a statistically significant association. Various cutoffs between -10% and -17% were used to define abnormal GLS across studies. This systematic review revealed that STE may predict mortality in patients with sepsis; however, the strength of evidence is low due to heterogeneity in study populations, GLS technologies, cutoffs, and timing of STE. Further dedicated studies are needed to understand the optimal application of STE in patients with sepsis.
Speckle reduction using deformable mirrors with diffusers in a laser pico-projector.
Chen, Hsuan-An; Pan, Jui-Wen; Yang, Zu-Po
2017-07-24
We propose a design for speckle reduction in a laser pico-projector adopting diffusers and deformable mirrors. This research focuses on speckle noise suppression by changing the angle of divergence of the diffuser. Moreover, the speckle contrast value can be further reduced by the addition of a deformable mirror. The speckle reduction ability obtained using diffusers with different divergence angles is compared. Three types of diffuser designs are compared in the experiments. For Type 1 which uses a circular symmetric diffuser the speckle contrast value can be decreased to 0.0264. For Type 2, the speckle contrast value can be reduced to 0.0267 because of the inclusion of an elliptical distribution diffuser. With Type 3 which includes a combination of the circular distribution diffuser and elliptical distribution diffuser, the speckle contrast value can be reduced to 0.0236. For all three types, the speckle contrast value is lower than 0.05. Under this speckle value, the speckle phenomenon is invisible to the human eye.
Smolarek, Dorota; Gruchała, Marcin; Sobiczewski, Wojciech
2017-01-01
Estimation of right ventricular (RV) performance still remains technically challenging due to its anatomical and functional distinctiveness. The current guidelines for the echocardiographic quantification of RV function recommend using multiple indices to describe the RV in a thorough and comprehensive manner, such as RV index of myocardial performance, tricuspid annular plane systolic excursion, fractional area change, Doppler tissue imaging-derived tricuspid lateral annular systolic velocity (S'-wave), three-dimensional RV ejection fraction (3D RVEF), RV longitudinal strain (RVLS)/strain rate by speckle- tracking echocardiography (STE). Among these, the last one mentioned here is an innovative and a particularly promising tool that yields more precise information about complex regional and global RV mechanics. STE was initially designed to evaluate left ventricular function, but recently it has been introduced to assess RV performance, which is difficult due to its unique structure and physiology. Many studies have shown that both free wall and 6-segment RVLS present a stronger correlation with the RVEF assessed by cardiac magnetic resonance than conventional parameters and seem to be more sensitive in detecting myocardial dysfunction at an earlier, subclinical stage.
Li, Yinbo; Garson, Christopher D.; Xu, Yaqin; Helm, Patrick A.; Hossack, John A.; French, Brent A.
2011-01-01
This study noninvasively evaluated the development of left ventricular (LV) dyssynchrony following reperfused myocardial infarction (MI) in mice using an ultrasonic speckle-tracking method. Eight C57BL/6J mice were assessed by high-resolution echocardiography at baseline and at eight time-points following MI. Images were acquired at 1mm elevational intervals encompassing the entire LV to determine chamber volumes and radial strain. Receiver-operating characteristic (ROC) analysis of regional radial strain was used to segment the three-dimensional (3-D) LV into infarct, adjacent and remote zones. This in vivo segmentation was correlated to histologic infarct size (R = 0.89, p < 0.01) in a short-axis, slice-by-slice comparison. The onset of dyssynchrony during LV remodeling was assessed by standard deviation of time to peak radial strain in the infarct, adjacent and remote zones. It was discovered that the form of LV dyssynchrony that develops in the remote zone late after MI does so in concert with the progression of LV remodeling (R = 0.70, p < 0.05). PMID:21640480
Pérez, Alberto J; González-Peña, Rolando J; Braga, Roberto; Perles, Ángel; Pérez-Marín, Eva; García-Diego, Fernando J
2018-01-11
Dynamic laser speckle (DLS) is used as a reliable sensor of activity for all types of materials. Traditional applications are based on high-rate captures (usually greater than 10 frames-per-second, fps). Even for drying processes in conservation treatments, where there is a high level of activity in the first moments after the application and slower activity after some minutes or hours, the process is based on the acquisition of images at a time rate that is the same in moments of high and low activity. In this work, we present an alternative approach to track the drying process of protective layers and other painting conservation processes that take a long time to reduce their levels of activity. We illuminate, using three different wavelength lasers, a temporary protector (cyclododecane) and a varnish, and monitor them using a low fps rate during long-term drying. The results are compared to the traditional method. This work also presents a monitoring method that uses portable equipment. The results present the feasibility of using the portable device and show the improved sensitivity of the dynamic laser speckle when sensing the long-term process for drying cyclododecane and varnish in conservation.
Evaluating platelet aggregation dynamics from laser speckle fluctuations
Hajjarian, Zeinab; Tshikudi, Diane M.; Nadkarni, Seemantini K.
2017-01-01
Platelets are key to maintaining hemostasis and impaired platelet aggregation could lead to hemorrhage or thrombosis. We report a new approach that exploits laser speckle intensity fluctuations, emanated from a drop of platelet-rich-plasma (PRP), to profile aggregation. Speckle fluctuation rate is quantified by the speckle intensity autocorrelation, g2(t), from which the aggregate size is deduced. We first apply this approach to evaluate polystyrene bead aggregation, triggered by salt. Next, we assess dose-dependent platelet aggregation and inhibition in human PRP spiked with adenosine diphosphate and clopidogrel. Additional spatio-temporal speckle analyses yield 2-dimensional maps of particle displacements to visualize platelet aggregate foci within minutes and quantify aggregation dynamics. These findings demonstrate the unique opportunity for assessing platelet health within minutes for diagnosing bleeding disorders and monitoring anti-platelet therapies. PMID:28717586
El Jalbout, Ramy; Cloutier, Guy; Cardinal, Marie-Hélène Roy; Henderson, Mélanie; Lapierre, Chantale; Soulez, Gilles; Dubois, Josée
2018-05-09
Common carotid artery intima-media thickness is a marker of subclinical atherosclerosis. In children, increased intima-media thickness is associated with obesity and the risk of cardiovascular events in adulthood. To compare intima-media thickness measurements using B-mode ultrasound, radiofrequency (RF) echo tracking, and RF speckle probability distribution in children with normal and increased body mass index (BMI). We prospectively measured intima-media thickness in 120 children randomly selected from two groups of a longitudinal cohort: normal BMI and increased BMI, defined by BMI ≥85th percentile for age and gender. We followed Mannheim recommendations. We used M'Ath-Std for automated B-mode imaging, M-line processing of RF signal amplitude for RF echo tracking, and RF signal segmentation and averaging using probability distributions defining image speckle. Statistical analysis included Wilcoxon and Mann-Whitney tests, and Pearson correlation coefficient and intra-class correlation coefficient (ICC). Children were 10-13 years old (mean: 11.7 years); 61% were boys. The mean age was 11.4 years (range: 10.0-13.1 years) for the normal BMI group and 12.0 years (range: 10.1-13.5 years) for the increased BMI group. The normal BMI group included 58% boys and the increased BMI group 63% boys. RF echo tracking method was successful in 79 children as opposed to 114 for the B-mode method and all 120 for the probability distribution method. Techniques were weakly correlated: ICC=0.34 (95% confidence interval [CI]: 0.27-0.39). Intima-media thickness was significantly higher in the increased BMI than normal BMI group using the RF techniques and borderline for the B-mode technique. Mean differences between weight groups were: B-mode, 0.02 mm (95% CI: 0.00 to 0.04), P=0.05; RF echo tracking, 0.03 mm (95% CI: 0.01 to 0.05), P=0.01; and RF speckle probability distribution, 0.03 mm (95% CI: 0.01 to 0.05), P=0.002. Though techniques are not interchangeable, all showed increased intima-media thickness in children with increased BMI. RF echo tracking method had the lowest success rate at calculating intima-media thickness. For patient follow-up and cohort comparisons, the same technique should be used throughout.
Simulations of x-ray speckle-based dark-field and phase-contrast imaging with a polychromatic beam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zdora, Marie-Christine, E-mail: marie-christine.zdora@diamond.ac.uk; Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE; Department of Physics & Astronomy, University College London, London WC1E 6BT
2015-09-21
Following the first experimental demonstration of x-ray speckle-based multimodal imaging using a polychromatic beam [I. Zanette et al., Phys. Rev. Lett. 112(25), 253903 (2014)], we present a simulation study on the effects of a polychromatic x-ray spectrum on the performance of this technique. We observe that the contrast of the near-field speckles is only mildly influenced by the bandwidth of the energy spectrum. Moreover, using a homogeneous object with simple geometry, we characterize the beam hardening artifacts in the reconstructed transmission and refraction angle images, and we describe how the beam hardening also affects the dark-field signal provided by specklemore » tracking. This study is particularly important for further implementations and developments of coherent speckle-based techniques at laboratory x-ray sources.« less
Parsaee, Mozhgan; Saedi, Sedigheh; Joghataei, Pegah; Azarkeivan, Azita; Alizadeh Sani, Zahra
2017-10-01
β-Thalassemia is an inherited hemoglobin disorder resulting in chronic hemolytic anemia requiring chronic transfusion therapy. Cardiac involvement is the main cause of death in patients with thalassemia major. The narrow border is between overt myocardial dysfunction and clinically silent left ventricular (LV) dysfunction in patients with thalassemia. Therefore, we need novel parameters in different imaging techniques to discover cardiac involvement in an early and subtle stage. We explore to find a novel, straightforward and informative parameter in echocardiography as a noninvasive, economical and really routine in clinical practice. In this prospective study, 55 patients, who are known cases of β-thalassemia major, receiving long-term blood transfusions and undergoing iron chelation therapy were enrolled. Ferritin level, cardiac magnetic resonance (CMR) T2 * value, full conventional echocardiography and speckle tracking, LV regional circumferential and longitudinal strain values (%) and time-to-peak strain (ms) of 17 segments cardiac model in eyeball tomogram were measured. There was a significant reduction in global longitudinal strain (GLS) (-20.9% ± 1.9 vs. -22.2 ± 1.03) and also basal segments longitudinal strain compared to normal subjects group (-17.4% ± 2.7 vs. -19.6% ± 1.2). There was no significant difference in circumferential strain value between thalassemia patients and normal control group. Interestingly, there was no significant correlation between GLS and CMR T2 * values showing no association between cardiac iron load and longitudinal strain. Speckle tracking echocardiography could be used as a feasible method for evaluating subclinical myocardial dysfunction in patients with thalassemia major. Echocardiography, using GLS, could predict clinically silent myocardial dysfunction independent of CMR (T2 * value) and extension of iron deposition. Our study also puts forward other causes such as chronic tissue hypoxia resulting from chronic anemia as a root cause and initiating factor for subsequent injury by the iron deposition. Speckle tracking can recognize the cardiac involvement in really early stages.
Madeo, Andrea; Piras, Paolo; Re, Federica; Gabriele, Stefano; Nardinocchi, Paola; Teresi, Luciano; Torromeo, Concetta; Chialastri, Claudia; Schiariti, Michele; Giura, Geltrude; Evangelista, Antonietta; Dominici, Tania; Varano, Valerio; Zachara, Elisabetta; Puddu, Paolo Emilio
2015-01-01
The assessment of left ventricular shape changes during cardiac revolution may be a new step in clinical cardiology to ease early diagnosis and treatment. To quantify these changes, only point registration was adopted and neither Generalized Procrustes Analysis nor Principal Component Analysis were applied as we did previously to study a group of healthy subjects. Here, we extend to patients affected by hypertrophic cardiomyopathy the original approach and preliminarily include genotype positive/phenotype negative individuals to explore the potential that incumbent pathology might also be detected. Using 3D Speckle Tracking Echocardiography, we recorded left ventricular shape of 48 healthy subjects, 24 patients affected by hypertrophic cardiomyopathy and 3 genotype positive/phenotype negative individuals. We then applied Generalized Procrustes Analysis and Principal Component Analysis and inter-individual differences were cleaned by Parallel Transport performed on the tangent space, along the horizontal geodesic, between the per-subject consensuses and the grand mean. Endocardial and epicardial layers were evaluated separately, different from many ecocardiographic applications. Under a common Principal Component Analysis, we then evaluated left ventricle morphological changes (at both layers) explained by first Principal Component scores. Trajectories’ shape and orientation were investigated and contrasted. Logistic regression and Receiver Operating Characteristic curves were used to compare these morphometric indicators with traditional 3D Speckle Tracking Echocardiography global parameters. Geometric morphometrics indicators performed better than 3D Speckle Tracking Echocardiography global parameters in recognizing pathology both in systole and diastole. Genotype positive/phenotype negative individuals clustered with patients affected by hypertrophic cardiomyopathy during diastole, suggesting that incumbent pathology may indeed be foreseen by these methods. Left ventricle deformation in patients affected by hypertrophic cardiomyopathy compared to healthy subjects may be assessed by modern shape analysis better than by traditional 3D Speckle Tracking Echocardiography global parameters. Hypertrophic cardiomyopathy pathophysiology was unveiled in a new manner whereby also diastolic phase abnormalities are evident which is more difficult to investigate by traditional ecocardiographic techniques. PMID:25875818
Charwat-Resl, S; Niessner, A; Mueller, M; Bartko, P E; Giurgea, G A; Zehetmayer, S; Willfort-Ehringer, A; Koppensteiner, R; Schlager, O
2016-10-01
Purpose: Vascular ultrasound (US) allows the analysis of vascular strain by speckle-tracking. This study sought to assess the extent to which vas cular strain varies between different segments of the arterial tree. Furthermore, this study aimed to investigate the reproducibility of vascular strain determination as well as of the components that contribute to the variance of vascular strain measurements in different vascular beds. Materials and Methods: Speckle-tracking was used to determine the vascular strain of the abdominal aorta (AA), the common carotid artery (CCA), the common femoral (CFA) and the popliteal artery (PA) of healthy adults. Intra- and interday reproducibility and the components of variance of vascular strain of the respective arteries were determined. Results: A total of 589 US clips obtained in 10 healthy adults (7 males, 28.3 ± 3.2 years) were analyzable. Vascular strain was 7.2 ± 3.0 % in the AA, 5.7 ± 2.1 % in the CCA, 2.1 ± 1.1 % in the CFA and 1.9 ± 1.1 % in the PA. The intraday coefficients of variation of vascular strain were 6.2 % (AA), 3.9 % (CCA), 3.3 % (CFA) and 6.1 % (PA), and the interday coefficients of variation were 5.9 % (AA), 8.4 % (CCA), 10 % (CFA) and 4.6 % (PA). The variance of vascular strain mainly depended on the investigated vessel and subject. Individual DUS clips, the day of examination and the (right/left) body side (in paired arteries) had no impact on the variance of vascular strain. Conclusion: Vascular strain substantially varies between different sites of the arterial tree. Speckle-tracking by DUS allows the reliable determination of vascular strain at different arterial sites. © Georg Thieme Verlag KG Stuttgart · New York.
Yu, Zhan; Li, Yuanyang; Liu, Lisheng; Guo, Jin; Wang, Tingfeng; Yang, Guoqing
2017-11-10
The speckle pattern (line by line) sequential extraction (SPSE) metric is proposed by the one-dimensional speckle intensity level crossing theory. Through the sequential extraction of received speckle information, the speckle metrics for estimating the variation of focusing spot size on a remote diffuse target are obtained. Based on the simulation, we will give some discussions about the SPSE metric range of application under the theoretical conditions, and the aperture size will affect the metric performance of the observation system. The results of the analyses are verified by the experiment. This method is applied to the detection of relative static target (speckled jitter frequency is less than the CCD sampling frequency). The SPSE metric can determine the variation of the focusing spot size over a long distance, moreover, the metric will estimate the spot size under some conditions. Therefore, the monitoring and the feedback of far-field spot will be implemented laser focusing system applications and help the system to optimize the focusing performance.
Speeding up 3D speckle tracking using PatchMatch
NASA Astrophysics Data System (ADS)
Zontak, Maria; O'Donnell, Matthew
2016-03-01
Echocardiography provides valuable information to diagnose heart dysfunction. A typical exam records several minutes of real-time cardiac images. To enable complete analysis of 3D cardiac strains, 4-D (3-D+t) echocardiography is used. This results in a huge dataset and requires effective automated analysis. Ultrasound speckle tracking is an effective method for tissue motion analysis. It involves correlation of a 3D kernel (block) around a voxel with kernels in later frames. The search region is usually confined to a local neighborhood, due to biomechanical and computational constraints. For high strains and moderate frame-rates, however, this search region will remain large, leading to a considerable computational burden. Moreover, speckle decorrelation (due to high strains) leads to errors in tracking. To solve this, spatial motion coherency between adjacent voxels should be imposed, e.g., by averaging their correlation functions.1 This requires storing correlation functions for neighboring voxels, thus increasing memory demands. In this work, we propose an efficient search using PatchMatch, 2 a powerful method to find correspondences between images. Here we adopt PatchMatch for 3D volumes and radio-frequency signals. As opposed to an exact search, PatchMatch performs random sampling of the search region and propagates successive matches among neighboring voxels. We show that: 1) Inherently smooth offset propagation in PatchMatch contributes to spatial motion coherence without any additional processing or memory demand. 2) For typical scenarios, PatchMatch is at least 20 times faster than the exact search, while maintaining comparable tracking accuracy.
Zhang, Xiaojie; Lu, Qing; Zhang, Zhuojun; Chen, Yongle; Wang, Yanan; Wang, Youngshi; Li, Zheng; Jiang, Lindi
2018-05-22
To assess the value of three-dimensional speckle tracking echocardiography (3D STE) in evaluating the left ventricular (LV) function in hyperuricemia patients. We enrolled 15 healthy controls and 40 hyperuricemia patients and collected and analyzed full-volume 3D STE images of the left ventricle in the apical four-chamber heart view. Laboratory tests and 3D STE parameters, including left ventricular ejection fraction, left ventricular end-diastolic volume, left ventricular end-systolic volume, stroke volume (SV), global longitudinal strain (GLS), and global circumferential strain (GCS), were compared between hyperuricemia patients and healthy controls. Hyperuricemia patients exhibited higher body mass index (24.70 ± 2.9 vs. 21.83 ± 2.4 kg/m 2 , p = 0.001), C-reactive protein (5.82 ± 9.4 vs. 1.12 ± 1.8 g/L, p = 0.012), alanine transaminase (34.26 ± 26.6 vs. 17.60 ± 13.0 U/L, p = 0.011), aspartate transaminase (24.90 ± 11.3 vs. 17.70 ± 4.1 U/L, p = 0.001), blood urea nitrogen (5.11 ± 1.6 vs. 4.18 ± 0.6 mmol/L, p = 0.046), and serum creatinine (90.25 ± 14.6 vs. 77.93 ± 10.8 μmol/L, p = 0.006) levels, as well as a lower estimated glomerular filtration rate (87.87 ± 16.5 vs. 103.64 ± 11.3 mL/min/1.73m 2 , p = 0.002). The 3D STE parameters reflecting LV function, including SV (54.71 ± 9.6 vs. 61.92 ± 14.4 mL, p = 0.024), GLS (- 20.51 ± 4.0 vs. - 23.20 ± 4.0%, p = 0.019), and GCS (- 31.30 ± 5.0 vs. - 35.65 ± 2.5%, p = 0.000), were significantly decreased in hyperuricemia patients. Furthermore, GCS was significantly correlated with the serum uric acid (sUA) level even after adjustment of confounding variables like age, body mass index, and serum creatinine. 3D STE is a novel technique for recognizing the early decline in LV function, with GLS and GCS serving as reliable indicators, in hyperuricemia patients. Moreover, the degree of decline in LV function may be correlated with the sUA level in hyperuricemia patients.
Iio, Chiharuko; Inoue, Katsuji; Nishimura, Kazuhisa; Fujii, Akira; Nagai, Takayuki; Suzuki, Jun; Okura, Takafumi; Higaki, Jitsuo; Ogimoto, Akiyoshi
2015-12-01
The pathological process of left ventricular (LV) hypertrophy is associated with left atrial (LA) remodeling. This study was aimed to evaluate the prognostic value of LA strain parameters in patients with pathological LV hypertrophy. This study included 95 patients with hypertensive heart disease (HHD: n = 24), hypertrophic cardiomyopathy (HCM: n = 56), cardiac amyloidosis (CA: n = 15), and control subjects (n = 20). We used two-dimensional speckle tracking echocardiography (STE) to analyze LA global strain. LA electromechanical conduction time (EMT) at the septal (EMT-septal) and lateral wall (EMT-lateral), and their time difference (EMT-diff) were calculated. The incidence of cardiac death and heart failure hospitalization was defined as major cardiac events and that of atrial fibrillation as secondary outcome. Left atrial volume index was increased and LA booster strain was decreased in the HCM and CA groups compared with the HHD group. EMT-lateral was increased in the diseased groups compared with the control. EMT-diff was prolonged in the CA group compared with the HCM group. During the follow-up period (mean 3.4 years), major cardiac events and atrial fibrillation occurred in 17 and 13 patients, respectively. The occurrence of atrial fibrillation was associated with CA etiology, E/e', LA volume index, LAa, and EMT-lateral. The incidence of major cardiac events was independently correlated with LA volume index and EMT-diff in multivariate analysis. This study suggested that the EMT-diff could discriminate patients with a high risk of cardiac events among patients with pathological LV hypertrophy. © 2015, Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Chien, C. H.; Swinson, W. F.; Turner, J. L.; Moslehy, F. A.; Ranson, W. F.
1980-01-01
A method for measuring in-plane displacement of a rotating structure by using two laser speckle photographs is described. From the displacement measurements one can calculate strains and stresses due to a centrifugal load. This technique involves making separate speckle photographs of a test model. One photograph is made with the model loaded (model is rotating); the second photograph is made with no load on the model (model is stationary). A sandwich is constructed from the two speckle photographs and data are recovered in a manner similar to that used with conventional speckle photography. The basic theory, experimental procedures of this method, and data analysis of a simple rotating specimen are described. In addition the measurement of in-plane surface displacement components of a deformed solid, and the application of the coupled laser speckle interferometry and boundary-integral solution technique to two dimensional elasticity problems are addressed.
Voigt, Jens-Uwe; Pedrizzetti, Gianni; Lysyansky, Peter; Marwick, Tom H; Houle, Hélène; Baumann, Rolf; Pedri, Stefano; Ito, Yasuhiro; Abe, Yasuhiko; Metz, Stephen; Song, Joo Hyun; Hamilton, Jamie; Sengupta, Partho P; Kolias, Theodore J; d'Hooge, Jan; Aurigemma, Gerard P; Thomas, James D; Badano, Luigi Paolo
2015-02-01
Recognizing the critical need for standardization in strain imaging, in 2010, the European Association of Echocardiography (now the European Association of Cardiovascular Imaging, EACVI) and the American Society of Echocardiography (ASE) invited technical representatives from all interested vendors to participate in a concerted effort to reduce intervendor variability of strain measurement. As an initial product of the work of the EACVI/ASE/Industry initiative to standardize deformation imaging, we prepared this technical document which is intended to provide definitions, names, abbreviations, formulas, and procedures for calculation of physical quantities derived from speckle tracking echocardiography and thus create a common standard. Copyright © 2015 American Society of Echocardiography. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kyoden, Tomoaki, E-mail: kyouden@nc-toyama.ac.jp; Naruki, Shoji; Akiguchi, Shunsuke
Two-beam multipoint laser Doppler velocimetry (two-beam MLDV) is a non-invasive imaging technique able to provide an image of two-dimensional blood flow and has potential for observing cancer as previously demonstrated in a mouse model. In two-beam MLDV, the blood flow velocity can be estimated from red blood cells passing through a fringe pattern generated in the skin. The fringe pattern is created at the intersection of two beams in conventional LDV and two-beam MLDV. Being able to choose the depth position is an advantage of two-beam MLDV, and the position of a blood vessel can be identified in a three-dimensionalmore » space using this technique. Initially, we observed the fringe pattern in the skin, and the undeveloped or developed speckle pattern generated in a deeper position of the skin. The validity of the absolute velocity value detected by two-beam MLDV was verified while changing the number of layers of skin around a transparent flow channel. The absolute velocity value independent of direction was detected using the developed speckle pattern, which is created by the skin construct and two beams in the flow channel. Finally, we showed the relationship between the signal intensity and the fringe pattern, undeveloped speckle, or developed speckle pattern based on the skin depth. The Doppler signals were not detected at deeper positions in the skin, which qualitatively indicates the depth limit for two-beam MLDV.« less
Three dimensional tracking with misalignment between display and control axes
NASA Technical Reports Server (NTRS)
Ellis, Stephen R.; Tyler, Mitchell; Kim, Won S.; Stark, Lawrence
1992-01-01
Human operators confronted with misaligned display and control frames of reference performed three dimensional, pursuit tracking in virtual environment and virtual space simulations. Analysis of the components of the tracking errors in the perspective displays presenting virtual space showed that components of the error due to visual motor misalignment may be linearly separated from those associated with the mismatch between display and control coordinate systems. Tracking performance improved with several hours practice despite previous reports that such improvement did not take place.
Visual object recognition and tracking
NASA Technical Reports Server (NTRS)
Chang, Chu-Yin (Inventor); English, James D. (Inventor); Tardella, Neil M. (Inventor)
2010-01-01
This invention describes a method for identifying and tracking an object from two-dimensional data pictorially representing said object by an object-tracking system through processing said two-dimensional data using at least one tracker-identifier belonging to the object-tracking system for providing an output signal containing: a) a type of the object, and/or b) a position or an orientation of the object in three-dimensions, and/or c) an articulation or a shape change of said object in said three dimensions.
Wang, W; Kang, Y; Shu, X H; Shen, X D; He, B
2017-11-23
Objective: To investigate the clinical value of two-dimensional speckle tracking echocardiography(2D-STE) combined with high-sensitive cardiac troponin T (hs-cTnT) in early detection of the cardiotoxicity induced by chemotherapy drug. Methods: Seventy-five non-Hodgkin's lymphoma patients who received the CHOP regimen were recruited in this study. Conventional echocardiography and 2D-STE were performed on these patients before chemotherapy, the second day after the third course of chemotherapy (during chemotherapy) and the second day after the last course of chemotherapy (after chemotherapy). The parameters included left ventricular ejection fraction (LVEF), global longitudinal strain (LS), global circumferential strain (CS) and global radial strain (RS). The serum hs-cTNT levels were tested simultaneously. Results: Three cycles of CHOP were completed in 30 patients and 6-8 cycles of CHOP were completed in 45 patients. The LVEF of 75 patients before, during and after chemotherapy was (63.8±2.6)%, (63.8±2.8)% and (64.0±3.3)%, respectively, without significant difference ( P =0.91). However, the LS of 75 patients before, during and after chemotherapy was (-18.5±1.7)%, (-16.5±1.9)% and (-16.0±1.6)%, respectively. The CS was (-20.9±2.9)%, (-19.3±3.5)% and (-19.2±3.2)%, respectively. The RS was (39.2±6.4)%, (35.3±5.2)% and (35.0±6.2)%, respectively. The hs-cTnT was (0.001 0±0.002 0)ng/ml, (0.006 3±0.008 9)ng/ml and (0.007 3±0.003 8)ng/ml, respectively. The LS, CS and RS were significantly decreased while hs-cTnT was significantly increased during chemotherapy when compared to those before chemotherapy (all of P <0.01). Alternatively, the LS, CS, RS and hs-cTnT after chemotherapy were marginally different from those during chemotherapy (all of P >0.05). Moreover, T(LS-SD), T(CS-SD) and T(RS-SD) showed no significant difference before, during and after chemotherapy (all of P >0.05). The reduction of LS was positively associated with the enhancement of hs-cTnT after chemotherapy ( r =0.60, P <0.01). Conclusion: 2D-STE combined with hs-cTnT can effectively and precisely detect the occult cardiotoxicity induced by anthracycline.
Navarini, Susanne; Bellsham-Revell, Hannah; Chubb, Henry; Gu, Haotian; Sinha, Manish D; Simpson, John M
2017-12-01
Systemic arterial hypertension predisposes children to cardiovascular risk in childhood and adult life. Despite extensive study of left ventricular (LV) hypertrophy, detailed 3-dimensional strain analysis of cardiac function in hypertensive children has not been reported. The aim of this study was to evaluate LV mechanics (strain, twist, and torsion) in young patients with hypertension compared with a healthy control group and assess factors associated with functional measurements. Sixty-three patients (26 hypertension and 37 normotensive) were enrolled (mean age, 14.3 and 11.4 years; 54% men and 41% men, respectively). All children underwent clinical evaluation and echocardiographic examination, including 3-dimensional strain. There was no difference in LV volumes and ejection fraction between the groups. Myocardial deformation was significantly reduced in those with hypertension compared with controls. For hypertensive and normotensive groups, respectively, global longitudinal strain was -15.1±2.3 versus -18.5±1.9 ( P <0.0001), global circumferential strain -15.2±3 versus -19.9±3.1 (<0.0001), global radial strain +44.0±11.3 versus 63.4±10.5 ( P <0.0001), and global 3-dimensional strain -26.1±3.8 versus -31.5±3.8 ( P <0.0001). Basal clockwise rotation, apical counterclockwise rotation, twist, and torsion were not significantly different. After multivariate regression analyses blood pressure, body mass index and LV mass maintained a significant relationship with measures of LV strain. Similar ventricular volumes and ejection fraction were observed in hypertensive and normotensive children, but children with hypertension had significantly lower strain indices. Whether reduced strain might predict future cardiovascular risk merits further longitudinal study. © 2017 American Heart Association, Inc.
Esmaeili, Mahdad; Dehnavi, Alireza Mehri; Rabbani, Hossein; Hajizadeh, Fedra
2017-01-01
The process of interpretation of high-speed optical coherence tomography (OCT) images is restricted due to the large speckle noise. To address this problem, this paper proposes a new method using two-dimensional (2D) curvelet-based K-SVD algorithm for speckle noise reduction and contrast enhancement of intra-retinal layers of 2D spectral-domain OCT images. For this purpose, we take curvelet transform of the noisy image. In the next step, noisy sub-bands of different scales and rotations are separately thresholded with an adaptive data-driven thresholding method, then, each thresholded sub-band is denoised based on K-SVD dictionary learning with a variable size initial dictionary dependent on the size of curvelet coefficients' matrix in each sub-band. We also modify each coefficient matrix to enhance intra-retinal layers, with noise suppression at the same time. We demonstrate the ability of the proposed algorithm in speckle noise reduction of 100 publically available OCT B-scans with and without non-neovascular age-related macular degeneration (AMD), and improvement of contrast-to-noise ratio from 1.27 to 5.12 and mean-to-standard deviation ratio from 3.20 to 14.41 are obtained.
Agha, Hala Mounir; Hamza, Hala S; Kotby, Alyaa; Ganzoury, Mona E L; Soliman, Nanies
2017-10-01
To evaluate the left ventricular function before and after transcatheter percutaneous patent ductus arteriosus (PDA) closure, and to identify the predictors of myocardial dysfunction post-PDA closure if present. Transcatheter PDA closure; conventional, Doppler, and tissue Doppler imaging; and speckle tracking echocardiography. To determine the feasibility and reliability of tissue Doppler and myocardial deformation imaging for evaluating myocardial function in children undergoing transcatheter PDA closure. Forty-two children diagnosed with hemodynamically significant PDA underwent percutaneous PDA closure. Conventional, Doppler, and tissue Doppler imaging, and speckle-derived strain rate echocardiography were performed at preclosure and at 48 hours, 1 month, and 6 months postclosure. Tissue Doppler velocities of the lateral and septal mitral valve annuli were obtained. Global and regional longitudinal peak systolic strain values were determined using two-dimensional speckle tracking echocardiography. The median age of the patients was 2 years and body weight was 15 kg, with the mean PDA diameter of 3.11 ± 0.99 mm. M-mode measurements (left ventricular end diastolic diameter, left atrium diameter to aortic annulus ratio, ejection fraction, and shortening fraction) reduced significantly early after PDA closure ( p < 0.001). After 1 month, left ventricular end diastolic diameter and left atrium diameter to aortic annulus ratio continued to decrease, while ejection fraction and fractional shortening improved significantly. All tissue Doppler velocities showed a significant decrease at 48 hours with significant prolongation of global myocardial function ( p < 0.001) and then were normalized within 1 month postclosure. Similarly, global longitudinal strain significantly decreased at 48 hours postclosure ( p < 0.001), which also recovered at 1 month follow-up. Preclosure global longitudinal strain showed a good correlation with the postclosure prolongation of the myocardial performance index. Transcatheter PDA closure causes a significant decrease in left ventricular performance early after PDA closure, which recovers completely within 1 month. Preclosure global longitudinal strain can be a predictor of postclosure myocardial dysfunction.
Visualization of spatial-temporal data based on 3D virtual scene
NASA Astrophysics Data System (ADS)
Wang, Xianghong; Liu, Jiping; Wang, Yong; Bi, Junfang
2009-10-01
The main purpose of this paper is to realize the expression of the three-dimensional dynamic visualization of spatialtemporal data based on three-dimensional virtual scene, using three-dimensional visualization technology, and combining with GIS so that the people's abilities of cognizing time and space are enhanced and improved by designing dynamic symbol and interactive expression. Using particle systems, three-dimensional simulation, virtual reality and other visual means, we can simulate the situations produced by changing the spatial location and property information of geographical entities over time, then explore and analyze its movement and transformation rules by changing the interactive manner, and also replay history and forecast of future. In this paper, the main research object is the vehicle track and the typhoon path and spatial-temporal data, through three-dimensional dynamic simulation of its track, and realize its timely monitoring its trends and historical track replaying; according to visualization techniques of spatialtemporal data in Three-dimensional virtual scene, providing us with excellent spatial-temporal information cognitive instrument not only can add clarity to show spatial-temporal information of the changes and developments in the situation, but also be used for future development and changes in the prediction and deduction.
Temporal Changes in Left Ventricular Mechanics: Impact of Bed Rest and Exercise
NASA Technical Reports Server (NTRS)
Scott, J. M.; Downs, M.; Ploutz-Snyder, L. L.
2014-01-01
The use of more sensitive and specific echocardiographic techniques such as speckle tracking imaging may address the current limitations of conventional cardiac imaging techniques to provide insight into the extent and time course of cardiac deconditioning following spaceflight or headdown tilt bed rest (HDTBR). METHODS Speckle tracking assessment of longitudinal, radial, and circumferential strain and twist was used to evaluate the impact of 70 days of HDTBR (n=7) and HDTBR + exercise (n=11) on temporal changes in LV mechanics. Echocardiograms were performed pre (BR-2), during (BR31, 70), and following (BR+4hr) HDTBR. Repeated measures ANOVA was used to evaluate the effect of HDTBR on cardiac variables in control and exercise subjects. RESULTS After sedentary HDTBR, longitudinal (-19.0 +/- 1.8% vs. -14.9 +/- 2.4%) and radial (15.0 +/- 1.9% vs. 11.3 +/- 2.2%) strain and twist (18.0 +/- 4.0deg vs. 17.0 +/- 3.6deg) were significantly impaired. In contrast, exercise preserved LV mechanics, and there were non-significant improvements from BR-2 to BR70 in longitudinal strain (-18.7 +/- 1.5% vs. -20.4 +/- 2.7%), radial strain (13.2 +/- 2.4% vs. 14.2 +/- 1.6%), and twist (16.3 +/- 3.6deg vs. 18.6 +/- 5.9deg). CONCLUSIONS Using speckle tracking echocardiography provides important new insights into temporal changes in LV mechanics during disuse and exercise training.
Kupczynska, Karolina; Michalski, Blazej W; Miskowiec, Dawid; Kasprzak, Jaroslaw D; Wejner-Mik, Paulina; Wdowiak-Okrojek, Katarzyna; Lipiec, Piotr
2017-07-01
The aim of the study was to investigate whether the deformation of left atrium (LA) measured by speckle-tracking analysis (STE) is associated with the presence of LA appendage thrombus (LAAT) during non-valvular atrial fibrillation (AF). Eighty-seven patients (mean age 67 years, 59% men) were included to retrospective cross-sectional study. On top of standard echocardiography we assessed: LA longitudinal systolic strain (LS), systolic (LSSR) and early diastolic strain rate (LESR) in four-chamber and twochamber apical views. All patients underwent transesophageal echocardiography disclosing LAAT in 36 (41%) patients. Subgroups with and without thrombi did not differ with regard to clinical characteristics. Univariate factors associated with LAAT were as follows: CH2ADS2-VASc Score, left ventricular ejection fraction (LVEF), LV mass, and STE measurements. In a multivariate model only LVEF (p=0.002), LS (p=0.02), LESR (p=0.008), and LSSR (p=0.045) were independently associated with LAAT presence. Moreover, LVEF and LA STE measurements provided incremental value over the CH2ADS2-VASc Score. Speckle-tracking TTE may be used to describe LA reservoir and conduit function during AF, allowing the identification of patients with higher risk of LAAT and providing incremental value over the CH2ADS2-VASc Score.
Germanakis, Ioannis; Matsui, Hikoro; Gardiner, Helena M
2012-01-01
To compare myocardial deformation patterns in fetuses with congenital heart disease (CHD) with our reference range using speckle tracking echocardiography. We prospectively stored and analyzed 4-chamber loops of 28 fetuses with CHD (median gestation 27 weeks, range 20.9-37.0). The peak longitudinal left (LVs) and right (RVs) ventricular free wall Lagrangian strain and LV/RV strain ratio were measured from Syngo VVI software- (Siemens) derived original coordinates. Strain values from the first examination were compared with normative data from the same population using ANOVA with post hoc tests and serial examinations described in 14 fetuses. Simple shunt lesions (0.82) and shunts with pulmonary stenosis or atresia (0.93) had reduced mean LV/RV strain ratios compared to normal fetuses (1.01; 95% CI 0.97-1.05). Fetuses with hypoplastic left heart had the lowest (0.29), and those with Ebstein the highest (1.55), LV:RV ratio. Serial measurements showed increased LVs in aortic coarctation and aortic stenosis, but not in one developing important mitral regurgitation. Increased right ventricular loading in a fetus developing pulmonary regurgitation was associated with increasing RVs. Myocardial strain reflects the changing physiology of fetal CHD. Speckle tracking might be a useful tool to study the progress of myocardial function in affected fetuses. Copyright © 2012 S. Karger AG, Basel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Hongchang, E-mail: hongchang.wang@diamond.ac.uk; Kashyap, Yogesh; Sawhney, Kawal
2016-03-21
X-ray dark-field contrast tomography can provide important supplementary information inside a sample to the conventional absorption tomography. Recently, the X-ray speckle based technique has been proposed to provide qualitative two-dimensional dark-field imaging with a simple experimental arrangement. In this letter, we deduce a relationship between the second moment of scattering angle distribution and cross-correlation degradation of speckle and establish a quantitative basis of X-ray dark-field tomography using single directional speckle scanning technique. In addition, the phase contrast images can be simultaneously retrieved permitting tomographic reconstruction, which yields enhanced contrast in weakly absorbing materials. Such complementary tomography technique can allow systematicmore » investigation of complex samples containing both soft and hard materials.« less
Alreshidan, Mohammed; Shahmansouri, Nastaran; Chung, Jennifer; Lash, Vynka; Emmott, Alexander; Leask, Richard L; Lachapelle, Kevin
2017-04-01
Ex vivo measurement of ascending aortic biomechanical properties may help understand the risk for rupture or dissection of dilated ascending aortas. A validated in vivo method that can predict aortic biomechanics does not exist. Speckle tracking transesophageal echocardiography (TEE) has been used to measure ventricular stiffness; we sought to determine whether speckle TEE could be adapted to estimate aortic stiffness in vivo and compare these findings with those obtained by ex vivo tissue measurements. A total of 17 patients undergoing ascending aortic resection were recruited to with a mean aortic diameter was 56.16 ± 15 mm. Intraoperative speckle TEE tracking analysis was used to calculate aortic stiffness index using the following equation: β2=ln(SBP/DBP)/AoS, where β2 is the stiffness index; SBP is systolic blood pressure; DBP is diastolic blood pressure; and AoS is the circumferential strain. Ex vivo stiffness was obtained by mechanical tissue testing according to previously described methods. The aortic ring at the pulmonary trunk was divided into 4 equal quadrants. The in vivo stiffness index for the inner curvature, anterior wall, outer curvature, and posterior wall were 0.0544 ± 0.0490, 0.0295 ± 0.0199, 0.0411 ± 0.0328, and 0.0502 ± 0.0320, respectively. The mean ex vivo 25% apparent stiffness for inner curvature, anterior wall, outer curvature, and posterior wall were 0.0616 ± 0.0758 MPa, 0.0352 ± 0.00992 MPa, 0.0405 ± 0.0199 MPa, and 0.0327 ± 0.0106 MPa, respectively. The patient-matched ex vivo 25% apparent stiffness and in vivo stiffness index were not significantly different (P = .8617, 2-way analysis of variance with repeated measures). The use of speckle TEE appears to be a promising technique to estimate ex vivo mechanical properties of the ascending aortic tissue. Copyright © 2016 The American Association for Thoracic Surgery. All rights reserved.
Pérez, Alberto J.; Braga, Roberto; Perles, Ángel; Pérez–Marín, Eva; García-Diego, Fernando J.
2018-01-01
Dynamic laser speckle (DLS) is used as a reliable sensor of activity for all types of materials. Traditional applications are based on high-rate captures (usually greater than 10 frames-per-second, fps). Even for drying processes in conservation treatments, where there is a high level of activity in the first moments after the application and slower activity after some minutes or hours, the process is based on the acquisition of images at a time rate that is the same in moments of high and low activity. In this work, we present an alternative approach to track the drying process of protective layers and other painting conservation processes that take a long time to reduce their levels of activity. We illuminate, using three different wavelength lasers, a temporary protector (cyclododecane) and a varnish, and monitor them using a low fps rate during long-term drying. The results are compared to the traditional method. This work also presents a monitoring method that uses portable equipment. The results present the feasibility of using the portable device and show the improved sensitivity of the dynamic laser speckle when sensing the long-term process for drying cyclododecane and varnish in conservation. PMID:29324692
Breast cancer early detection via tracking of skin back-scattered secondary speckle patterns
NASA Astrophysics Data System (ADS)
Bennett, Aviya; Sirkis, Talia; Beiderman, Yevgeny; Agdarov, Sergey; Beiderman, Yafim; Zalevsky, Zeev
2018-02-01
Breast cancer has become a major cause of death among women. The lifetime risk of a woman developing this disease has been established as one in eight. The most useful way to reduce breast cancer death is to treat the disease as early as possible. The existing methods of early diagnostics of breast cancer are mainly based on screening mammography or Magnetic Resonance Imaging (MRI) periodically conducted at medical facilities. In this paper the authors proposing a new approach for simple breast cancer detection. It is based on skin stimulation by sound waves, illuminating it by laser beam and tracking the reflected secondary speckle patterns. As first approach, plastic balls of different sizes were placed under the skin of chicken breast and detected by the proposed method.
Advanced one-dimensional optical strain measurement system, phase 4
NASA Technical Reports Server (NTRS)
Lant, Christian T.
1992-01-01
An improved version of the speckle-shift strain measurement system was developed. The system uses a two-dimensional sensor array to maintain speckle correlation in the presence of large off-axis rigid body motions. A digital signal processor (DSP) is used to calculate strains at a rate near the RS-170 camera frame rate. Strain measurements were demonstrated on small diameter wires and fibers used in composite materials research. Accurate values of Young's modulus were measured on tungsten wires, and silicon carbide and sapphire fibers. This optical technique has measured surface strains at specimen temperatures above 750 C and has shown the potential for measurements at much higher temperatures.
Three-dimensional orbit and physical parameters of HD 6840
NASA Astrophysics Data System (ADS)
Wang, Xiao-Li; Ren, Shu-Lin; Fu, Yan-Ning
2016-02-01
HD 6840 is a double-lined visual binary with an orbital period of ˜7.5 years. By fitting the speckle interferometric measurements made by the 6 m BTA telescope and 3.5 m WIYN telescope, Balega et al. gave a preliminary astrometric orbital solution of the system in 2006. Recently, Griffin derived a precise spectroscopic orbital solution from radial velocities observed with OPH and Cambridge Coravel. However, due to the low precision of the determined orbital inclination, the derived component masses are not satisfying. By adding the newly collected astrometric data in the Fourth Catalog of Interferometric Measurements of Binary Stars, we give a three-dimensional orbit solution with high precision and derive the preliminary physical parameters of HD 6840 via a simultaneous fit including both astrometric and radial velocity measurements.
Reif, Roberto; Qin, Jia; Shi, Lei; Dziennis, Suzan; Zhi, Zhongwei; Nuttall, Alfred L; Wang, Ruikang K
2012-01-01
A synchronized dual-wavelength laser speckle contrast imaging (DWLSCI) system and a Doppler optical microangiography (DOMAG) system was developed to determine several ischemic parameters in the cochlea due to a systemic hypoxic challenge. DWLSCI can obtain two-dimensional data, and was used to determine the relative changes in cochlear blood flow, and change in the concentrations of oxyhemoglobin (HbO), deoxyhemoglobin (Hb) and total hemoglobin (HbT) in mice. DOMAG can obtain three-dimensional data, and was used to determine the changes in cochlear blood flow with single vessel resolution. It was demonstrated that during a hypoxic challenge there was an increase in the concentrations of Hb, a decrease in the concentrations of HbO and cochlear blood flow, and a slight decrease in the concentration of HbT. Also, the rate of change in the concentrations of Hb and HbO was quantified during and after the hypoxic challenge. The ability to simultaneously measure these ischemic parameters with high spatio-temporal resolution will allow the detailed quantitative analysis of several hearing disorders, and will be useful for diagnosing and developing treatments.
NASA Technical Reports Server (NTRS)
Barton, Richard J.; Ni, David; Ngo, Phong
2010-01-01
Several prototype ultra-wideband (UWB) impulse-radio (IR) tracking systems are currently under development at NASA Johnson Space Center (JSC). These systems are being studied for use in tracking of Lunar/Mars rovers and astronauts during early exploration missions when satellite navigation systems (such as GPS) are not available. To date, the systems that have been designed and tested are intended only for two-dimensional location and tracking, but these designs can all be extended to three-dimensional tracking with only minor modifications and increases in complexity. In this presentation, we will briefly review the design and performance of two of the current 2-D systems: one designed specifically for short-range, extremely high-precision tracking (approximately 1-2 cm resolution) and the other designed specifically for much longer range tracking with less stringent precision requirements (1-2 m resolution). We will then discuss a new multi-purpose system design based on a simple UWB-IR architecture that can be deployed easily on a planetary surface to support arbitrary three-dimensional localization and tracking applications. We will discuss utilization of this system as an infrastructure to provide both short-range and long-range tracking and analyze the localization performance of the system in several different configurations. We will give theoretical performance bounds for some canonical system configurations and compare these performance bounds with both numerical simulations of the system as well as actual experimental system performance evaluations.
Zuo, Houjuan; Yan, Jiangtao; Zeng, Hesong; Li, Wenyu; Li, Pengcheng; Liu, Zhengxiang; Cui, Guanglin; Lv, Jiagao; Wang, Daowen; Wang, Hong
2015-01-01
Global longitudinal strain (GLS) measured by 2-D speckle-tracking echocardiography (2-D STE) at rest has been recognized as a sensitive parameter in the detection of significant coronary artery disease (CAD). However, the diagnostic power of 2-D STE in the detection of significant CAD in patients with diabetes mellitus is unknown. Two-dimensional STE features were studied in total of 143 consecutive patients who underwent echocardiography and coronary angiography. Left ventricular global and segmental peak systolic longitudinal strains (PSLSs) were quantified by speckle-tracking imaging. In the presence of obstructive CAD (defined as stenosis ≥75%), global PSLS was significantly lower in patients with diabetes mellitus than in patients without (16.65 ± 2.29% vs. 17.32 ± 2.27%, p < 0.05). Receiver operating characteristic analysis revealed that global PSLS could effectively detect obstructive CAD in patients without diabetes mellitus (cutoff value: -18.35%, sensitivity: 78.8%, specificity: 77.5%). However, global PSLS could detect obstructive CAD in diabetic patients at a lower cutoff value with inadequate sensitivity and specificity (cutoff value: -17.15%; sensitivity: 61.1%, specificity: 52.9%). In addition, the results for segmental PSLS were similar to those for global PSLS. In conclusion, global and segmental PSLSs at rest were significantly lower in patients with both obstructive CAD and diabetes mellitus than in patients with obstructive CAD only; thus, PSLSs at rest might not be a useful parameter in the detection of obstructive CAD in patients with diabetes mellitus. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Ferferieva, V; Van den Bergh, A; Claus, P; Jasaityte, R; La Gerche, A; Rademakers, F; Herijgers, P; D'hooge, J
2013-08-01
This study was designed in order to compare the strain and strain rate deformation parameters assessed by speckle tracking imaging (STI) with those of tissue Doppler imaging (TDI) and conductance catheter measurements in chronic murine models of left ventricular (LV) dysfunction. Twenty-four male C57BL/6J mice were assigned to wild-type (n = 8), myocardial infarction (n = 8) and transaortic constriction (n = 8) groups. Echocardiographic and conductance measurements were simultaneously performed at rest and during dobutamine infusion (5 µg/kg/min) in all animals 10 weeks post-surgery. The LV circumferential strain (Scirc) and the strain rate (SRcirc) were derived from grey scale and tissue Doppler data at frame rates of 224 and 375 Hz, respectively. Scirc and SRcirc by TDI/STI correlated well with the preload recruitable stroke work (PRSW) (r = -0.64 and -0.71 for TDI; r = -0.46 and -0.50 for STI, P < 0.05). Both modalities showed a good agreement with respect to Scirc and SRcirc (r = 0.60 and r = 0.63, P < 0.05). During stress, however, TDI-estimated Scirc and SRcirc values were predominantly higher than those measured by STI (P < 0.05). The similarity of Scirc and SRcirc measurements with respect to the STI/TDI data was examined by the Bland-Altman analysis. In mice, the STI- and TDI-derived strain and strain rate deformation parameters relate closely to intrinsic myocardial function. At low heart rate-to-frame rate ratios (HR/FR), both STI and TDI are equally acceptable for assessing the LV function non-invasively in these animals. At HR/FR (e.g. dobutamine challenge), however, these methods cannot be used interchangeably as STI underestimates S and SR at high values.
Liu, Dan; Hu, Kai; Herrmann, Sebastian; Cikes, Maja; Ertl, Georg; Weidemann, Frank; Störk, Stefan; Nordbeck, Peter
2017-06-01
Prognosis of patients with light-chain cardiac amyloidosis (AL-CA) is poor. Speckle tracking imaging (STI) derived longitudinal deformation parameters and Doppler-derived left ventricular (LV) Tei index are valuable predictors of outcome in patients with AL-CA. We estimated the prognostic utility of Tei index and deformation parameters in 58 comprehensively phenotyped patients with AL-CA after a median follow-up of 365 days (quartiles 121, 365 days). The primary end point was all-cause mortality. 19 (33%) patients died during follow-up. Tei index (0.89 ± 0.29 vs. 0.61 ± 0.16, p < 0.001) and E to global early diastolic strain rate ratio (E/GLSR dias ) were higher while global longitudinal systolic strain (GLS sys ) was lower in non-survivors than in survivors (all p < 0.05). Tei index, NYHA functional class, GLS sys and E/GLSR dias were independent predictors of all-cause mortality risk, and Tei index ≥0.9 (HR 7.01, 95% CI 2.43-20.21, p < 0.001) was the best predictor of poor outcome. Combining Tei index and GLS sys yielded the best results on predicting death within 1 year (100% with Tei index ≥0.9 and GLS sys ≤13%) or survival (95% with Tei index ≤0.9 and GLS sys ≥13%). We conclude that 1-year mortality risk in AL-CA patients can be reliably predicted using Tei index or deformation parameters, with combined analysis offering best performance.
Ujka, Kristian; Bastiani, Luca; D'Angelo, Gennaro; Catuzzo, Bruna; Tonacci, Alessandro; Mrakic-Sposta, Simona; Vezzoli, Alessandra; Giardini, Guido; Pratali, Lorenza
2017-01-01
Background: Strenuous and endurance exercise training have been associated with morphological and functional heart remodeling. Two-dimensional speckle-tracking echocardiography (STE) is a novel technique that allows an accurate quantification of global myocardium deformation. Our aim was to evaluate together left and right cardiac remodeling in different long-distance running athletes: marathon runners (42 km) (M) and endurance mountain runners (>300 Km) (UT). Methods: A total of 92 athletes (70 males, 76%) including 47 M [age 45 ± 7 years; training: 18 (9–53) years*days/week], 45 UT [age 42 ± 9, training: 30 (15–66) years*days/week] underwent conventional echocardiography and STE (Beyond Diogenes 2.0, AMID) during the agonistic season. Results: Right ventricle (RV) end-diastolic area (p = 0.026), fractional area changing (FAC) (p = 0.008) and RV global longitudinal strain (GLS) were significantly increasedin UT athletes. Furthermore, UT showed larger right atrium (RA) volume (p = 0.03), reduced RA GLS and significantly increased RA global circumferential strain (GCS) compared to M. After adjustment for age, sex, and HR as covariates, UT showed a reduced RA GLS (OR 0.907; CI 0.856–0.961) and increased RV FAC (OR 1.172; CI: 1.044–1.317) compared to M. Conclusion: Athletes enrolled in UT endurance activities showed RV and RA morphological and functional remodeling to increased preload in comparison with M runners characterized by increased RV FAC and reduced RA GLS. Follow-up studies are needed to better assess the long-term clinical impact of these modifications. 2D STE is a useful tool for investigating the deformation dynamic in different sports specialties. PMID:28790928
Biocompatible Near-Infrared Three-Dimensional Tracking System.
Decker, Ryan S; Shademan, Azad; Opfermann, Justin D; Leonard, Simon; Kim, Peter C W; Krieger, Axel
2017-03-01
A fundamental challenge in soft-tissue surgery is that target tissue moves and deforms, becomes occluded by blood or other tissue, and is difficult to differentiate from surrounding tissue. We developed small biocompatible near-infrared fluorescent (NIRF) markers with a novel fused plenoptic and NIR camera tracking system, enabling three-dimensional tracking of tools and target tissue while overcoming blood and tissue occlusion in the uncontrolled, rapidly changing surgical environment. In this work, we present the tracking system and marker design and compare tracking accuracies to standard optical tracking methods using robotic experiments. At speeds of 1 mm/s, we observe tracking accuracies of 1.61 mm, degrading only to 1.71 mm when the markers are covered in blood and tissue.
Speckle interferometry of asteroids
NASA Technical Reports Server (NTRS)
Drummond, Jack D.; Hege, E. Keith
1989-01-01
Steward Observatory's two-dimensional power spectrum signature analysis of speckle interferometry observations is summarized. Results for six asteroids are presented. The poles and triaxial ellipsoid dimensions of 4 Vesta, 433 Eros, 511 Davida, and 532 Herculina have been previously reported. New results for 2 Pallas and 29 Amphitrite are given, as well as further results for Vesta. Image reconstruction is ultimately required to minimize biasing effects of asteroid surface features on the simpler power spectrum analysis. Preliminary imaging results have been achieved for Vesta and Eros, and images for these two are displayed. Speckle interferometry and radiometry diameters are compared, and diameters from the two occultations of Pallas are addressed.
Double-pulse digital speckle pattern interferometry for vibration analysis
NASA Astrophysics Data System (ADS)
Zhang, Dazhi; Xue, Jingfeng; Chen, Lu; Wen, Juying; Wang, Jingjing
2014-12-01
The double-pulse Digital Speckle Pattern Interferometry (DSPI) in the laboratory is established. Two good performances have been achieved at the same time, which is uniform distribution of laser beam energy by space filter and recording two successive pictures by a CCD camera successfully. Then two-dimensional discrete orthogonal wavelet transform method is used for the process of filtering method. By using the DSPI, speckle pattern of a vibrated object is obtained with interval of (2~800)μs, and 3D plot of the transient vibration is achieved. Moreover, good agreements of the mode shapes and displacement are obtained by comparing with Laser Doppler Vibrometer (LDV) .
Shang, Zhijuan; Su, Dechun; Cong, Tao; Sun, Yinghui; Liu, Yan; Chen, Na; Yang, Jun
2017-02-01
The aim of this study was to investigate left atrial (LA) function and synchrony in paroxysmal atrial fibrillation (PAF) patients using two-dimensional speckle tracking echocardiography (STE). Forty-five PAF patients and 30 healthy controls were enrolled. LA peak ventricular systolic longitudinal strain (LA S -S ) and strain rate (LA SR -S ) and left atrial longitudinal strain (LA S -A ) and strain rate (LA SR -A ) during late diastole were determined using STE, and the standard deviation of the time to peak (TPSD) of the regional strains was calculated to quantify LA dyssynchrony. TPSD during ventricular systole and late diastole were named SDs and SDa, respectively. Left atrial peak longitudinal strain during ventricular systole (LA S -S ) (29.34±8.57 vs 36.73±6.13), LA SR -S (1.27±0.311 vs 1.57±0.25), LA S -A (13.11±4.91 vs 17.86±3.57), and LA SR -A (-1.51±0.58 vs -1.90±0.30) were reduced in the PAF group compared with the controls (P<.05 for all). SDs (8.11±3.00% vs 4.67±1.48%) and SDa (5.57±2.26% vs 3.11±1.13%) were greater in PAF patients than in the controls (P<.05 for both). Furthermore, PAF patients with normal LA sizes exhibited lower LA S -S (P<.05), LA SR -S (P<.05), LA S -A (P<.05), and LA SR -A (P<.05) values and increased SDs (P<.05) and SDa (P<.05) values compared with the controls. Multivariate regression confirmed that SDs and SDa were powerful parameters for differentiating PAF patients from controls (SDs: sensitivity, 83%; specificity, 72%; SDa: sensitivity, 81%; specificity, 76%). Left atrial (LA) dysfunction and dyssynchrony in PAF patients can be detected with STE even in the absence of LA enlargement. STE-derived SDs and SDa were powerful parameters for identifying PAF patients. © 2017, Wiley Periodicals, Inc.
Echocardiography and cardiac resynchronisation therapy, friends or foes?
van Everdingen, W M; Schipper, J C; van 't Sant, J; Ramdat Misier, K; Meine, M; Cramer, M J
2016-01-01
Echocardiography is used in cardiac resynchronisation therapy (CRT) to assess cardiac function, and in particular left ventricular (LV) volumetric status, and prediction of response. Despite its widespread applicability, LV volumes determined by echocardiography have inherent measurement errors, interobserver and intraobserver variability, and discrepancies with the gold standard magnetic resonance imaging. Echocardiographic predictors of CRT response are based on mechanical dyssynchrony. However, parameters are mainly tested in single-centre studies or lack feasibility. Speckle tracking echocardiography can guide LV lead placement, improving volumetric response and clinical outcome by guiding lead positioning towards the latest contracting segment. Results on optimisation of CRT device settings using echocardiographic indices have so far been rather disappointing, as results suffer from noise. Defining response by echocardiography seems valid, although re-assessment after 6 months is advisable, as patients can show both continuous improvement as well as deterioration after the initial response. Three-dimensional echocardiography is interesting for future implications, as it can determine volume, dyssynchrony and viability in a single recording, although image quality needs to be adequate. Deformation patterns from the septum and the derived parameters are promising, although validation in a multicentre trial is required. We conclude that echocardiography has a pivotal role in CRT, although clinicians should know its shortcomings.
Levy, Philip T.; Sanchez, Aura; Machefsky, Aliza; Fowler, Susan; Holland, Mark R.; Singh, Gautam K.
2014-01-01
Background Establishment of the range of normal values and associated variations of two-dimensional speckle-tracking echocardiography (2DSTE) derived right ventricular (RV) strain is a prerequisite for its routine clinical application in children. The objectives of this study were to perform a meta-analysis of normal ranges of RV longitudinal strain measurements derived by 2DSTE in children and identify confounders that may contribute to differences in reported measures. Methods A systematic review was launched in PubMed, Embase, Scopus, Cochrane, and ClinicTrials.gov. Search hedges were created to cover the concepts of pediatrics, speckle-tracking echocardiography, and right heart ventricle. Two investigators independently identified and included studies if they reported the 2DSTE derived RV strain measures: RV peak global longitudinal strain (pGLS), systolic strain rate (pGLSRs), early diastolic strain rate (pGLSRe), late diastolic strain rate (pGLSRa), or segmental longitudinal strain at the apical, mid, and basal ventricular levels in healthy children. Quality and reporting of the studies were assessed. The weighted mean was estimated by using random-effects with 95% confidence intervals (CI), heterogeneity was assessed by the Cochran's Q statistic and the inconsistency index (I2), and publication bias was evaluated using funnel plots and the Egger test. Effects of demographic, clinical, equipment, and software variables were assessed in a meta-regression. Results The search identified 226 children from 10 studies. The reported normal mean values of pGLS among the studies varied from −20.80% to −34.10% (mean, −29.03%, 95%CI, −31.52% to −26.54%), pGLSRs varied from −1.30 to −2.40 1/sec (mean, −1.88, 95%CI, −2.10 to −1.59), pGLSRe ranged from 1.7 to 2.69 1/sec (mean, 2.34, 95%CI, 2.00 to 2.67) and pGLSRa ranged from 1.00 to 1.30 1/sec (mean, 1.18, 95% CI, 1.04 to 1.33). A significant base-to-apex segmental strain gradient (p <0.05) was observed in the right ventricular free wall. There was significant between-study heterogeneity and inconsistency (I2>88% and p<0.01 for each strain measure), which was not explained by age, gender, body surface area, heart rate, frame rate, tissue tracking methodology, equipment, or software. The meta-regression showed that these effects were not significant determinants of variations among normal ranges of strain values. There was no evidence of publication bias (Egger test, p=0.59). Conclusions This study is the first to define normal values of two-dimensional speckle tracking echocardiographic (2DSTE) derived right ventricle strain in children on the basis of a meta-analysis. The normal mean value in children for RV global strain is −29.03% (95% CI, −31.52% to −26.54%). The normal mean value for RV global systolic strain rate is −1.88 1/sec (95% CI, −2.10 to −1.59). RV segmental strain has a stable base-to-apex gradient that highlights the dominance of deep longitudinal layers of the RV that are aligned base to apex. Variations among different normal ranges do not appear to be dependent on differences in demographic, clinical, or equipment parameters in this meta-analysis. All of the eligible studies used equipment and software from one manufacturer, General Electric (GE). PMID:24582163
Imaging two-dimensional mechanical waves of skeletal muscle contraction.
Grönlund, Christer; Claesson, Kenji; Holtermann, Andreas
2013-02-01
Skeletal muscle contraction is related to rapid mechanical shortening and thickening. Recently, specialized ultrasound systems have been applied to demonstrate and quantify transient tissue velocities and one-dimensional (1-D) propagation of mechanical waves during muscle contraction. Such waves could potentially provide novel information on musculoskeletal characteristics, function and disorders. In this work, we demonstrate two-dimensional (2-D) mechanical wave imaging following the skeletal muscle contraction. B-mode image acquisition during multiple consecutive electrostimulations, speckle-tracking and a time-stamp sorting protocol were used to obtain 1.4 kHz frame rate 2-D tissue velocity imaging of the biceps brachii muscle contraction. The results present novel information on tissue velocity profiles and mechanical wave propagation. In particular, counter-propagating compressional and shear waves in the longitudinal direction were observed in the contracting tissue (speed 2.8-4.4 m/s) and a compressional wave in the transverse direction of the non-contracting muscle tissue (1.2-1.9 m/s). In conclusion, analysing transient 2-D tissue velocity allows simultaneous assessment of both active and passive muscle tissue properties. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Gladysz, Szymon; Yaitskova, Natalia; Christou, Julian C
2010-11-01
This paper is an introduction to the problem of modeling the probability density function of adaptive-optics speckle. We show that with the modified Rician distribution one cannot describe the statistics of light on axis. A dual solution is proposed: the modified Rician distribution for off-axis speckle and gamma-based distribution for the core of the point spread function. From these two distributions we derive optimal statistical discriminators between real sources and quasi-static speckles. In the second part of the paper the morphological difference between the two probability density functions is used to constrain a one-dimensional, "blind," iterative deconvolution at the position of an exoplanet. Separation of the probability density functions of signal and speckle yields accurate differential photometry in our simulations of the SPHERE planet finder instrument.
Three-dimensional tracking solar energy concentrator and method for making same
NASA Technical Reports Server (NTRS)
Miller, C. G.; Pohl, J. G. (Inventor)
1977-01-01
A three dimensional tracking solar energy concentrator, consisting of a stretched aluminized polymeric membrane supported by a hoop, was presented. The system is sturdy enough to withstand expected windage forces and precipitation. It can provide the high temperature output needed by central station power plants for power production in the multi-megawatt range.
Demirelli, Selami; Degirmenci, Husnu; Ermis, Emrah; Inci, Sinan; Nar, Gokay; Ayhan, Mehmet Emin; Fırtına, Serdar; Hamur, Hikmet; Durmaz, Senay Arikan
2015-10-19
Polycystic ovary syndrome (PCOS) is characterized by hormonal and metabolic abnormalities and is thought to increase a risk for cardiovascular diseases. In this study we use speckle tracking echocardiography (STE) to evaluate left ventricular (LV) dysfunction in the early period of the disease. We enrolled 31 patients with PCOS and 32 healthy volunteers as a control group. The participants' ages ranged between 18 and 40 years. PCOS was diagnosed according to the Rotterdam criteria. LV strain (LS) and strain rate (SR) were evaluated using apical two-chamber (2C), three-chamber (3C), and four-chamber (4C) imaging. Global LS and SR were calculated as average of three apical views. The waist-to-hip ratio, homeostasis model assessment-insulin resistance (HOMA-IR), and fasting insulin and triglyceride levels were higher in the PCOS group than in the controls (p=0.001, p=0.001, p=0.001, and p=0.005, respectively). In the PCOS group, the mitral A wave, deceleration time (DT), and isovolumetric relaxation time (IVRT) were significantly higher than in the controls (all p<0.05). The LV global longitudinal strain (GLS) and global longitudinal SR systolic (GLSRS) were significantly lower in the PCOS patient group (both p= 0.001). There were strong negative correlations between GLS and both fasting insulin (r=-0.64) and DT (r=-0.62) (both p<0.05). The study demonstrated that PCOS patients had decreased LV function using STE. Therefore, STE imaging appears to be useful for the early detection of subclinical LV dysfunction in patients with PCOS.
Voigt, Jens-Uwe; Pedrizzetti, Gianni; Lysyansky, Peter; Marwick, Tom H; Houle, Helen; Baumann, Rolf; Pedri, Stefano; Ito, Yasuhiro; Abe, Yasuhiko; Metz, Stephen; Song, Joo Hyun; Hamilton, Jamie; Sengupta, Partho P; Kolias, Theodore J; d'Hooge, Jan; Aurigemma, Gerard P; Thomas, James D; Badano, Luigi Paolo
2015-01-01
Recognizing the critical need for standardization in strain imaging, in 2010, the European Association of Echocardiography (now the European Association of Cardiovascular Imaging, EACVI) and the American Society of Echocardiography (ASE) invited technical representatives from all interested vendors to participate in a concerted effort to reduce intervendor variability of strain measurement. As an initial product of the work of the EACVI/ASE/Industry initiative to standardize deformation imaging, we prepared this technical document which is intended to provide definitions, names, abbreviations, formulas, and procedures for calculation of physical quantities derived from speckle tracking echocardiography and thus create a common standard. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
Barlow, Paul M.
1997-01-01
Steady-state, two- and three-dimensional, ground-water-flow models coupled with particle tracking were evaluated to determine their effectiveness in delineating contributing areas of wells pumping from stratified-drift aquifers of Cape Cod, Massachusetts. Several contributing areas delineated by use of the three-dimensional models do not conform to simple ellipsoidal shapes that are typically delineated by use of two-dimensional analytical and numerical modeling techniques and included discontinuous areas of the water table.
Fluorescent speckle microscopy of microtubules: how low can you go?
Waterman-Storer, C M; Salmon, E D
1999-12-01
Fluorescent speckle microscopy (FSM) is a new technique for visualizing the movement, assembly, and turnover of macromolecular assemblies like the cytoskeleton in living cells. In this method, contrast is created by coassembly of a small fraction of fluorescent subunits in a pool of unlabeled subunits. Random variation in association creates a nonuniform "fluorescent speckle" pattern. Fluorescent speckle movements in time-lapse recordings stand out to the eye and can be measured. Because fluorescent speckles represent fiduciary marks on the polymer lattice, FSM provides the opportunity for the first time to see the 2- and 3-dimensional trajectories of lattice movements within large arrays of polymers as well as identifying sites of assembly and disassembly of individual polymers. The technique works with either microinjection of fluorescently labeled subunits or expression of subunits ligated to green fluorescent protein (GFP). We have found for microtubules assembled in vitro that speckles containing one fluorophore can be detected and recorded using a conventional wide-field epi-fluorescence light microscope and digital imaging with a low noise cooled CCD camera. In living cells, optimal speckle contrast occurs at fractions of labeled tubulin of approximately 0.1-0.5% where the fluorescence of each speckle corresponds to one to seven fluorophores per resolvable unit (approximately 0.27 microm) in the microscope. This small fraction of labeled subunits significantly reduces out-of-focus fluorescence and greatly improves visibility of fluorescently labeled structures and their dynamics in thick regions of living cells.
[Present status and trend of heart fluid mechanics research based on medical image analysis].
Gan, Jianhong; Yin, Lixue; Xie, Shenghua; Li, Wenhua; Lu, Jing; Luo, Anguo
2014-06-01
With introduction of current main methods for heart fluid mechanics researches, we studied the characteristics and weakness for three primary analysis methods based on magnetic resonance imaging, color Doppler ultrasound and grayscale ultrasound image, respectively. It is pointed out that particle image velocity (PIV), speckle tracking and block match have the same nature, and three algorithms all adopt block correlation. The further analysis shows that, with the development of information technology and sensor, the research for cardiac function and fluid mechanics will focus on energy transfer process of heart fluid, characteristics of Chamber wall related to blood fluid and Fluid-structure interaction in the future heart fluid mechanics fields.
An overview of methods to mitigate artifacts in optical coherence tomography imaging of the skin.
Adabi, Saba; Fotouhi, Audrey; Xu, Qiuyun; Daveluy, Steve; Mehregan, Darius; Podoleanu, Adrian; Nasiriavanaki, Mohammadreza
2018-05-01
Optical coherence tomography (OCT) of skin delivers three-dimensional images of tissue microstructures. Although OCT imaging offers a promising high-resolution modality, OCT images suffer from some artifacts that lead to misinterpretation of tissue structures. Therefore, an overview of methods to mitigate artifacts in OCT imaging of the skin is of paramount importance. Speckle, intensity decay, and blurring are three major artifacts in OCT images. Speckle is due to the low coherent light source used in the configuration of OCT. Intensity decay is a deterioration of light with respect to depth, and blurring is the consequence of deficiencies of optical components. Two speckle reduction methods (one based on artificial neural network and one based on spatial compounding), an attenuation compensation algorithm (based on Beer-Lambert law) and a deblurring procedure (using deconvolution), are described. Moreover, optical properties extraction algorithm based on extended Huygens-Fresnel (EHF) principle to obtain some additional information from OCT images are discussed. In this short overview, we summarize some of the image enhancement algorithms for OCT images which address the abovementioned artifacts. The results showed a significant improvement in the visibility of the clinically relevant features in the images. The quality improvement was evaluated using several numerical assessment measures. Clinical dermatologists benefit from using these image enhancement algorithms to improve OCT diagnosis and essentially function as a noninvasive optical biopsy. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Virtual three-dimensional blackboard: three-dimensional finger tracking with a single camera
NASA Astrophysics Data System (ADS)
Wu, Andrew; Hassan-Shafique, Khurram; Shah, Mubarak; da Vitoria Lobo, N.
2004-01-01
We present a method for three-dimensional (3D) tracking of a human finger from a monocular sequence of images. To recover the third dimension from the two-dimensional images, we use the fact that the motion of the human arm is highly constrained owing to the dependencies between elbow and forearm and the physical constraints on joint angles. We use these anthropometric constraints to derive a 3D trajectory of a gesticulating arm. The system is fully automated and does not require human intervention. The system presented can be used as a visualization tool, as a user-input interface, or as part of some gesture-analysis system in which 3D information is important.
NASA Astrophysics Data System (ADS)
Reinhart, Anna Merle; Spindeldreier, Claudia Katharina; Jakubek, Jan; Martišíková, Mária
2017-06-01
Carbon ion beam radiotherapy enables a very localised dose deposition. However, even small changes in the patient geometry or positioning errors can significantly distort the dose distribution. A live, non-invasive monitoring system of the beam delivery within the patient is therefore highly desirable, and could improve patient treatment. We present a novel three-dimensional method for imaging the beam in the irradiated object, exploiting the measured tracks of single secondary ions emerging under irradiation. The secondary particle tracks are detected with a TimePix stack—a set of parallel pixelated semiconductor detectors. We developed a three-dimensional reconstruction algorithm based on maximum likelihood expectation maximization. We demonstrate the applicability of the new method in the irradiation of a cylindrical PMMA phantom of human head size with a carbon ion pencil beam of {226} MeV u-1. The beam image in the phantom is reconstructed from a set of nine discrete detector positions between {-80}^\\circ and {50}^\\circ from the beam axis. Furthermore, we demonstrate the potential to visualize inhomogeneities by irradiating a PMMA phantom with an air gap as well as bone and adipose tissue surrogate inserts. We successfully reconstructed a three-dimensional image of the treatment beam in the phantom from single secondary ion tracks. The beam image corresponds well to the beam direction and energy. In addition, cylindrical inhomogeneities with a diameter of {2.85} cm and density differences down to {0.3} g cm-3 to the surrounding material are clearly visualized. This novel three-dimensional method to image a therapeutic carbon ion beam in the irradiated object does not interfere with the treatment and requires knowledge only of single secondary ion tracks. Even with detectors with only a small angular coverage, the three-dimensional reconstruction of the fragmentation points presented in this work was found to be feasible.
Reinhart, Anna Merle; Spindeldreier, Claudia Katharina; Jakubek, Jan; Martišíková, Mária
2017-06-21
Carbon ion beam radiotherapy enables a very localised dose deposition. However, even small changes in the patient geometry or positioning errors can significantly distort the dose distribution. A live, non-invasive monitoring system of the beam delivery within the patient is therefore highly desirable, and could improve patient treatment. We present a novel three-dimensional method for imaging the beam in the irradiated object, exploiting the measured tracks of single secondary ions emerging under irradiation. The secondary particle tracks are detected with a TimePix stack-a set of parallel pixelated semiconductor detectors. We developed a three-dimensional reconstruction algorithm based on maximum likelihood expectation maximization. We demonstrate the applicability of the new method in the irradiation of a cylindrical PMMA phantom of human head size with a carbon ion pencil beam of [Formula: see text] MeV u -1 . The beam image in the phantom is reconstructed from a set of nine discrete detector positions between [Formula: see text] and [Formula: see text] from the beam axis. Furthermore, we demonstrate the potential to visualize inhomogeneities by irradiating a PMMA phantom with an air gap as well as bone and adipose tissue surrogate inserts. We successfully reconstructed a three-dimensional image of the treatment beam in the phantom from single secondary ion tracks. The beam image corresponds well to the beam direction and energy. In addition, cylindrical inhomogeneities with a diameter of [Formula: see text] cm and density differences down to [Formula: see text] g cm -3 to the surrounding material are clearly visualized. This novel three-dimensional method to image a therapeutic carbon ion beam in the irradiated object does not interfere with the treatment and requires knowledge only of single secondary ion tracks. Even with detectors with only a small angular coverage, the three-dimensional reconstruction of the fragmentation points presented in this work was found to be feasible.
Active dynamics of colloidal particles in time-varying laser speckle patterns
Bianchi, Silvio; Pruner, Riccardo; Vizsnyiczai, Gaszton; Maggi, Claudio; Di Leonardo, Roberto
2016-01-01
Colloidal particles immersed in a dynamic speckle pattern experience an optical force that fluctuates both in space and time. The resulting dynamics presents many interesting analogies with a broad class of non-equilibrium systems like: active colloids, self propelled microorganisms, transport in dynamical intracellular environments. Here we show that the use of a spatial light modulator allows to generate light fields that fluctuate with controllable space and time correlations and a prescribed average intensity profile. In particular we generate ring-shaped random patterns that can confine a colloidal particle over a quasi one-dimensional random energy landscape. We find a mean square displacement that is diffusive at both short and long times, while a superdiffusive or subdiffusive behavior is observed at intermediate times depending on the value of the speckles correlation time. We propose two alternative models for the mean square displacement in the two limiting cases of a short or long speckles correlation time. A simple interpolation formula is shown to account for the full phenomenology observed in the mean square displacement across the entire range from fast to slow fluctuating speckles. PMID:27279540
NASA Astrophysics Data System (ADS)
Kachach, Redouane; Cañas, José María
2016-05-01
Using video in traffic monitoring is one of the most active research domains in the computer vision community. TrafficMonitor, a system that employs a hybrid approach for automatic vehicle tracking and classification on highways using a simple stationary calibrated camera, is presented. The proposed system consists of three modules: vehicle detection, vehicle tracking, and vehicle classification. Moving vehicles are detected by an enhanced Gaussian mixture model background estimation algorithm. The design includes a technique to resolve the occlusion problem by using a combination of two-dimensional proximity tracking algorithm and the Kanade-Lucas-Tomasi feature tracking algorithm. The last module classifies the shapes identified into five vehicle categories: motorcycle, car, van, bus, and truck by using three-dimensional templates and an algorithm based on histogram of oriented gradients and the support vector machine classifier. Several experiments have been performed using both real and simulated traffic in order to validate the system. The experiments were conducted on GRAM-RTM dataset and a proper real video dataset which is made publicly available as part of this work.
Lensless digital holography with diffuse illumination through a pseudo-random phase mask.
Bernet, Stefan; Harm, Walter; Jesacher, Alexander; Ritsch-Marte, Monika
2011-12-05
Microscopic imaging with a setup consisting of a pseudo-random phase mask, and an open CMOS camera, without an imaging objective, is demonstrated. The pseudo random phase mask acts as a diffuser for an incoming laser beam, scattering a speckle pattern to a CMOS chip, which is recorded once as a reference. A sample which is afterwards inserted somewhere in the optical beam path changes the speckle pattern. A single (non-iterative) image processing step, comparing the modified speckle pattern with the previously recorded one, generates a sharp image of the sample. After a first calibration the method works in real-time and allows quantitative imaging of complex (amplitude and phase) samples in an extended three-dimensional volume. Since no lenses are used, the method is free from lens abberations. Compared to standard inline holography the diffuse sample illumination improves the axial sectioning capability by increasing the effective numerical aperture in the illumination path, and it suppresses the undesired so-called twin images. For demonstration, a high resolution spatial light modulator (SLM) is programmed to act as the pseudo-random phase mask. We show experimental results, imaging microscopic biological samples, e.g. insects, within an extended volume at a distance of 15 cm with a transverse and longitudinal resolution of about 60 μm and 400 μm, respectively.
HWANG, HUI-JEONG; YOON, KYUNG LIM; SOHN, IL SUK
2016-01-01
The present study reported the case of a 60-year-old female with patent ductus arteriosus (PDA) and a bicuspid aortic valve, who presented with transient severe left ventricular (LV) dysfunction following percutaneous closure of PDA, as identified by speckle tracking analysis. Transient LV dysfunction following PDA closure has previously been reported; however, severe LV dysfunction is rare. In the present case, the combination of a large PDA size, large amount of shunting, LV remodeling and bicuspid aortic valve may have induced serious deterioration of LV function following PDA closure. Furthermore, speckle-tracking echocardiography may be useful in the estimation of functional alterations in the myocardium of the LV following PDA closure. The observations detailed in the present study may improve the understanding of the pathophysiology and myocardial patterns of transient left ventricular dysfunction following PDA closure in adult humans. PMID:26998021
Hwang, Hui-Jeong; Yoon, Kyung Lim; Sohn, Il Suk
2016-03-01
The present study reported the case of a 60-year-old female with patent ductus arteriosus (PDA) and a bicuspid aortic valve, who presented with transient severe left ventricular (LV) dysfunction following percutaneous closure of PDA, as identified by speckle tracking analysis. Transient LV dysfunction following PDA closure has previously been reported; however, severe LV dysfunction is rare. In the present case, the combination of a large PDA size, large amount of shunting, LV remodeling and bicuspid aortic valve may have induced serious deterioration of LV function following PDA closure. Furthermore, speckle-tracking echocardiography may be useful in the estimation of functional alterations in the myocardium of the LV following PDA closure. The observations detailed in the present study may improve the understanding of the pathophysiology and myocardial patterns of transient left ventricular dysfunction following PDA closure in adult humans.
Quantification and Reconstruction in Photoacoustic Tomography
NASA Astrophysics Data System (ADS)
Guo, Zijian
Optical absorption is closely associated with many physiological important parameters, such as the concentration and oxygen saturation of hemoglobin. Conventionally, accurate quantification in PAT requires knowledge of the optical fluence attenuation, acoustic pressure attenuation, and detection bandwidth. We circumvent this requirement by quantifying the optical absorption coefficients from the acoustic spectra of PA signals acquired at multiple optical wavelengths. We demonstrate the method using the optical-resolution photoacoustic microscopy (OR-PAM) and the acoustical-resolution photoacoustic microscopy (AR-PAM) in the optical ballistic regime and in the optical diffusive regime, respectively. The data acquisition speed in photoacoustic computed tomography (PACT) is limited by the laser repetition rate and the number of parallel ultrasound detecting channels. Reconstructing an image with fewer measurements can effectively accelerate the data acquisition and reduce the system cost. We adapted Compressed Sensing (CS) for the reconstruction in PACT. CS-based PACT was implemented as a non-linear conjugate gradient descent algorithm and tested with both phantom and in vivo experiments. Speckles have been considered ubiquitous in all scattering-based coherent imaging technologies. As a coherent imaging modality based on optical absorption, photoacoustic (PA) tomography (PAT) is generally devoid of speckles. PAT suppresses speckles by building up prominent boundary signals, via a mechanism similar to that of specular reflection. When imaging smooth boundary absorbing targets, the speckle visibility in PAT, which is defined as the ratio of the square root of the average power of speckles to that of boundaries, is inversely proportional to the square root of the absorber density. If the surfaces of the absorbing targets have uncorrelated height fluctuations, however, the boundary features may become fully developed speckles. The findings were validated by simulations and experiments. The first- and second-order statistics of PAT speckles were also studied experimentally. While the amplitude of the speckles follows a Gaussian distribution, the autocorrelation of the speckle patterns tracks that of the system point spread function.
NASA Astrophysics Data System (ADS)
Salmon, Neil A.
2017-10-01
Aperture synthesis for passive millimetre wave imaging provides a means to screen people for concealed threats in the extreme near-field configuration of a portal, a regime where the imager to subject distance is of the order of both the required depth-of-field and the field-of-view. Due to optical aberrations, focal plane array imagers cannot deliver the large depth-of-fields and field-of-views required in this regime. Active sensors on the other hand can deliver these but face challenges of illumination, speckle and multi-path issues when imaging canyon regions of the body. Fortunately an aperture synthesis passive millimetre wave imaging system can deliver large depth-of-fields and field-of-views, whilst having no speckle effects, as the radiometric emission from the human body is spatially incoherent. Furthermore, as in portal security screening scenarios the aperture synthesis imaging technique delivers a half-wavelength spatial resolution, it can effectively screen the whole of the human body. Some recent measurements are presented that demonstrate the three-dimensional imaging capability of extended sources using a 22 GHz aperture synthesis system. A comparison is made between imagery generated via the analytic Fourier transform and a gridding fast Fourier transform method. The analytic Fourier transform enables aliasing in the imagery to be more clearly identified. Some initial results are also presented of how the Gerchberg technique, an image enhancement algorithm used in radio astronomy, is adapted for three-dimensional imaging in security screening. This technique is shown to be able to improve the quality of imagery, without adding extra receivers to the imager. The requirements of a walk through security screening system for use at entrances to airport departure lounges are discussed, concluding that these can be met by an aperture synthesis imager.
Optimal speckle noise reduction filter for range gated laser illuminated imaging
NASA Astrophysics Data System (ADS)
Dayton, David; Gonglewski, John; Lasche, James; Hassall, Arthur
2016-09-01
Laser illuminated imaging has a number of applications in the areas of night time air-to-ground target surveillance, ID, and pointing and tracking. Using a laser illuminator, the illumination intensity and thus the signal to noise ratio can be controlled. With the advent of high performance range gated cameras in the short-wave infra-red band, higher spatial resolution can be achieved over passive thermal night imaging cameras in the mid-wave infra-red due to the shorter wave-length. If a coherent illuminator is used the resulting imagery often suffers from speckle noise due to the scattering off of a rough target surface, which gives it a grainy "salt and pepper" appearance. The probability density function for the intensity of focal plane speckle is well understood to follow a negative exponential distribution. This can be exploited to develop a Bayesian speckle noise filter. The filter has the advantage over simple frame averaging approaches in that it preserves target features and motion while reducing speckle noise without smearing or blurring the images. The resulting filtered images have the appearance of passive imagery and so are more amenable to sensor fusion with simultaneous mid-wave infra-red thermal images for enhanced target ID. The noise filter improvement is demonstrated using examples from real world laser imaging tests on tactical targets.
Novel use of pleural ultrasound can identify malignant entrapped lung prior to effusion drainage.
Salamonsen, Matthew R; Lo, Ada K C; Ng, Arnold C T; Bashirzadeh, Farzad; Wang, William Y S; Fielding, David I K
2014-11-01
The presence of entrapped lung changes the appropriate management of malignant pleural effusion from pleurodesis to insertion of an indwelling pleural catheter. No methods currently exist to identify entrapped lung prior to effusion drainage. Our objectives were to develop a method to identify entrapped lung using tissue movement and deformation (strain) analysis with ultrasonography and compare it to the existing technique of pleural elastance (PEL). Prior to drainage, 81 patients with suspected malignant pleural effusion underwent thoracic ultrasound using an echocardiogram machine. Images of the atelectatic lower lobe were acquired during breath hold, allowing motion and strain related to the cardiac impulse to be analyzed using motion mode (M mode) and speckle-tracking imaging, respectively. PEL was measured during effusion drainage. The gold-standard diagnosis of entrapped lung was the consensus opinion of two interventional pulmonologists according to postdrainage imaging. Participants were randomly divided into development and validation sets. Both total movement and strain were significantly reduced in entrapped lung. Using data from the development set, the area under the receiver-operating curves for the diagnosis of entrapped lung was 0.86 (speckle tracking), 0.79 (M mode), and 0.69 (PEL). Using respective cutoffs of 6%, 1 mm, and 19 cm H2O on the validation set, the sensitivity/specificity was 71%/85% (speckle tracking), 50%/85% (M mode), and 40%/100% (PEL). This novel ultrasound technique can identify entrapped lung prior to effusion drainage, which could allow appropriate choice of definitive management (pleurodesis vs indwelling catheter), reducing the number of interventions required to treat malignant pleural effusion.
Sandwich holospeckle interferometry for three-dimensional displacement determination
NASA Astrophysics Data System (ADS)
Wu, X. P.; Chiang, F. P.
1986-06-01
A sandwich holospecklegram (SH) technique with flexible sensitivity is presented for performing both in-plane and out-of-plane displacement measurements of objects. An object beam from a laser is directed onto a part-mirror onto which the object image is also directed and produces interference in the beam. The beam is redirected to fall, with a reference beam, onto photographic and speckle plates with their emulsion sides against one another, ergo, the sandwich. Reconstruction methods are delineated and illustrated with an SH of a crack in an aluminum alloy plate undergoing a three-point bending test. The crack is noted to occur in a region only 2 mm across.
Simulation of radiation effects on three-dimensional computer optical memories
NASA Technical Reports Server (NTRS)
Moscovitch, M.; Emfietzoglou, D.
1997-01-01
A model was developed to simulate the effects of heavy charged-particle (HCP) radiation on the information stored in three-dimensional computer optical memories. The model is based on (i) the HCP track radial dose distribution, (ii) the spatial and temporal distribution of temperature in the track, (iii) the matrix-specific radiation-induced changes that will affect the response, and (iv) the kinetics of transition of photochromic molecules from the colored to the colorless isomeric form (bit flip). It is shown that information stored in a volume of several nanometers radius around the particle's track axis may be lost. The magnitude of the effect is dependent on the particle's track structure.
NASA Technical Reports Server (NTRS)
Tilley, David G.
1988-01-01
The surface wave field produced by Hurricane Josephine was imaged by the L-band SAR aboard the Challenger on October 12, 1984. Exponential trends found in the two-dimensional autocorrelations of speckled image data support an equilibrium theory model of sea surface hydrodynamics. The notions of correlated specular reflection, surface coherence, optimal Doppler parameterization and spatial resolution are discussed within the context of a Poisson-Rayleigh statistical model of the SAR imaging process.
Speckle contrast diffuse correlation tomography of complex turbid medium flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Chong; Irwin, Daniel; Lin, Yu
2015-07-15
Purpose: Developed herein is a three-dimensional (3D) flow contrast imaging system leveraging advancements in the extension of laser speckle contrast imaging theories to deep tissues along with our recently developed finite-element diffuse correlation tomography (DCT) reconstruction scheme. This technique, termed speckle contrast diffuse correlation tomography (scDCT), enables incorporation of complex optical property heterogeneities and sample boundaries. When combined with a reflectance-based design, this system facilitates a rapid segue into flow contrast imaging of larger, in vivo applications such as humans. Methods: A highly sensitive CCD camera was integrated into a reflectance-based optical system. Four long-coherence laser source positions were coupledmore » to an optical switch for sequencing of tomographic data acquisition providing multiple projections through the sample. This system was investigated through incorporation of liquid and solid tissue-like phantoms exhibiting optical properties and flow characteristics typical of human tissues. Computer simulations were also performed for comparisons. A uniquely encountered smear correction algorithm was employed to correct point-source illumination contributions during image capture with the frame-transfer CCD and reflectance setup. Results: Measurements with scDCT on a homogeneous liquid phantom showed that speckle contrast-based deep flow indices were within 12% of those from standard DCT. Inclusion of a solid phantom submerged below the liquid phantom surface allowed for heterogeneity detection and validation. The heterogeneity was identified successfully by reconstructed 3D flow contrast tomography with scDCT. The heterogeneity center and dimensions and averaged relative flow (within 3%) and localization were in agreement with actuality and computer simulations, respectively. Conclusions: A custom cost-effective CCD-based reflectance 3D flow imaging system demonstrated rapid acquisition of dense boundary data and, with further studies, a high potential for translatability to real tissues with arbitrary boundaries. A requisite correction was also found for measurements in the fashion of scDCT to recover accurate speckle contrast of deep tissues.« less
Fang, Hui; Tang, Hailin; Li, Peng; Xiong, Li; Hu, Gongpai; Li, Li; Yu, Yonghong; Zhao, Bowen
2017-03-01
The objective of this study was to assess left atrial (LA) function with two-dimensional speckle tracking echocardiography (2DSTE) in addition to standard echocardiographic assessments in patients with hypertrophic obstructive cardiomyopathy (HOCM) before and 1 year after septal ablation (SA). The study included 31 patients with HOCM, who underwent SA. Each patient with HOCM underwent a complete two-dimensional transthoracic echocardiography before and 1 year after the SA. The measurements included basal septal thickness, left ventricular outflow trace (LVOT) gradient, mitral regurgitation (MR) grade, LA dimensions, left ventricular (LV) ejection fraction, and tissue Doppler parameters of lateral mitral annular e' and septal mitral annular e'. The LA wall was tracked on a frame-by-frame basis using 2DSTE, and LA volume waveforms were generated. The maximum LA volume (LAV max ), minimal LA volume (LAV min ), and the LA volume before atrial contraction (LAV pre-a ) were measured. The LA reservoir function was calculated as the expansion index and diastolic emptying index. The LA conduit function was calculated as the passive emptying percentage of total emptying (PE) and the passive emptying index (PEI). The LA booster function was calculated as the active emptying percentage of total emptying (AE) and the active emptying index (AEI). The LVOT gradient, end-diastolic septal base thickness, the grade of MR, and LA end-diastolic size were significantly decreased in patients with HOCM before and 1 year after the SA (All P<.05). The lateral mitral annular e' was significantly increased (P<.05), and the E/lateral e' ratio was significantly decreased (P<.05), whereas septal mitral annular e' was significantly decreased (P<.05), and the E/septal e' ratio was significantly increased (P<.05). LAVI max , LAVI min , and LAVI pre-a were significantly decreased 1 year after the SA (All P<.05). The expansion and diastolic emptying indices were significantly increased (All P<.05) at 1 year after the SA. PE and PEI were significantly increased (All P<.05). The AE and AEI were significantly decreased (All P<.05). LAVI max , LAVI min , and LAVI pre-a of the responders group were significantly lower than those of the nonresponders group (All P<.05). The expansion and diastolic emptying indices of the responders group were significantly higher than those of the nonresponders group (All P<.05). The PE and PEI of the responders were significantly higher than those of the nonresponders group (All P<.05). The AE and AEI of the responders were significantly lower than those of the nonresponders group (All P<.05). We found an improvement in the LA reservoir and conduit function but a reduction in LA booster pump function 1 year after the SA in the responders. © 2017, Wiley Periodicals, Inc.
Three-dimensional microscope tracking system using the astigmatic lens method and a profile sensor
NASA Astrophysics Data System (ADS)
Kibata, Hiroki; Ishii, Katsuhiro
2018-03-01
We developed a three-dimensional microscope tracking system using the astigmatic lens method and a profile sensor, which provides three-dimensional position detection over a wide range at the rate of 3.2 kHz. First, we confirmed the range of target detection of the developed system, where the range of target detection was shown to be ± 90 µm in the horizontal plane and ± 9 µm in the vertical plane for a 10× objective lens. Next, we attempted to track a motion-controlled target. The developed system kept the target at the center of the field of view and in focus up to a target speed of 50 µm/s for a 20× objective lens. Finally, we tracked a freely moving target. We successfully demonstrated the tracking of a 10-µm-diameter polystyrene bead suspended in water for 40 min. The target was kept in the range of approximately 4.9 µm around the center of the field of view. In addition, the vertical direction was maintained in the range of ± 0.84 µm, which was sufficiently within the depth of focus.
Podbreznik, Peter; Đonlagić, Denis; Lešnik, Dejan; Cigale, Boris; Zazula, Damjan
2013-10-01
A cost-efficient plastic optical fiber (POF) system for unobtrusive monitoring of human vital signs is presented. The system is based on speckle interferometry. A laser diode is butt-coupled to the POF whose exit face projects speckle patterns onto a linear optical sensor array. Sequences of acquired speckle images are transformed into one-dimensional signals by using the phase-shifting method. The signals are analyzed by band-pass filtering and a Morlet-wavelet-based multiresolutional approach for the detection of cardiac and respiratory activities, respectively. The system is tested with 10 healthy nonhospitalized persons, lying supine on a mattress with the embedded POF. Experimental results are assessed statistically: precisions of 98.8% ± 1.5% and 97.9% ± 2.3%, sensitivities of 99.4% ± 0.6% and 95.3% ± 3%, and mean delays between interferometric detections and corresponding referential signals of 116.6 ± 55.5 and 1299.2 ± 437.3 ms for the heartbeat and respiration are obtained, respectively.
Moreira, Henrique T; Volpe, Gustavo J; Marin-Neto, José A; Nwabuo, Chike C; Ambale-Venkatesh, Bharath; Gali, Luis G; Almeida-Filho, Oswaldo C; Romano, Minna M D; Pazin-Filho, Antonio; Maciel, Benedito C; Lima, João A C; Schmidt, André
2017-05-01
Chagas disease leads to biventricular heart failure, usually with prominent systemic congestion. Although echocardiography is widely used in clinical routine, the utility of echocardiographic parameters to detect right ventricular (RV) systolic dysfunction in patients with Chagas disease is unknown. We sought to study the diagnostic value of echocardiography, including speckle-tracking parameters, to distinguish individuals with RV systolic dysfunction from those with normal RV systolic function in Chagas disease using cardiac magnetic resonance (CMR) as the reference method. In this cross-sectional study, 63 individuals with Chagas disease underwent echocardiography and CMR evaluations. Conventional echocardiographic parameters for RV functional evaluation were tricuspid annular plane systolic excursion, RV systolic excursion velocity, fractional area change, and RV index of myocardial performance. Strain and strain rate were obtained by two-dimensional speckle-tracking echocardiography and defined as "RV free wall," when based only in segments from RV free wall, or "RV free wall and septum," when segments from both free RV wall and interventricular septum were included. RV systolic dysfunction was defined as RV ejection fraction (RVEF) < 50% by CMR. Mean age was 56 ± 14 years, and 58.7% of the patients were men. RV systolic dysfunction was detected by CMR in 18 (28.6%) individuals. RV free wall strain showed the highest correlation with RVEF by CMR (r = -0.62, P < .001), followed by fractional area change (r = 0.56, P < .001), RV free wall and septum strain (r = -0.54, P < .001), RV free wall and septum strain rate (r = -0.47, P < .001), RV free wall strain rate (r = -0.45, P < .001), and RV systolic excursion velocity (r = 0.30, P = .016). The RV index of myocardial performance and tricuspid annular plane systolic excursion showed a small and not significant correlation with RVEF (r = -0.20, P = .320; r = 0.14; P = .289, respectively). Using predefined cutoffs for RV systolic dysfunction, RV free wall strain (>-22.5% for men and >-23.3% for women) exhibited the highest area under the receiver operating characteristic curve (area under the curve = 0.829) to differentiate the presence from the absence of RV systolic dysfunction in Chagas disease, with a sensitivity and specificity of 67% and 83%, respectively. RV free wall strain is an appropriate and superior echocardiographic variable for evaluating RV systolic function in Chagas disease, and it should be the method of choice for this purpose. Copyright © 2017 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Zhong, Chunyan; Guo, Yanli; Huang, Haiyun; Tan, Liwen; Wu, Yi; Wang, Wenting
2013-01-01
To establish 3D models of coronary arteries (CA) and study their application in localization of CA segments identified by Transthoracic Echocardiography (TTE). Sectional images of the heart collected from the first CVH dataset and contrast CT data were used to establish 3D models of the CA. Virtual dissection was performed on the 3D models to simulate the conventional sections of TTE. Then, we used 2D ultrasound, speckle tracking imaging (STI), and 2D ultrasound plus 3D CA models to diagnose 170 patients and compare the results to coronary angiography (CAG). 3D models of CA distinctly displayed both 3D structure and 2D sections of CA. This simulated TTE imaging in any plane and showed the CA segments that corresponded to 17 myocardial segments identified by TTE. The localization accuracy showed a significant difference between 2D ultrasound and 2D ultrasound plus 3D CA model in the severe stenosis group (P < 0.05) and in the mild-to-moderate stenosis group (P < 0.05). These innovative modeling techniques help clinicians identify the CA segments that correspond to myocardial segments typically shown in TTE sectional images, thereby increasing the accuracy of the TTE-based diagnosis of CHD.
Rothschild, Freda; Bishop, Alexis I; Kitchen, Marcus J; Paganin, David M
2014-03-24
The Cornu spiral is, in essence, the image resulting from an Argand-plane map associated with monochromatic complex scalar plane waves diffracting from an infinite edge. Argand-plane maps can be useful in the analysis of more general optical fields. We experimentally study particular features of Argand-plane mappings known as "vorticity singularities" that are associated with mapping continuous single-valued complex scalar speckle fields to the Argand plane. Vorticity singularities possess a hierarchy of Argand-plane catastrophes including the fold, cusp and elliptic umbilic. We also confirm their connection to vortices in two-dimensional complex scalar waves. The study of vorticity singularities may also have implications for higher-dimensional fields such as coherence functions and multi-component fields such as vector and spinor fields.
Rodriguez-Hernandez, Miguel A; Gomez-Sacristan, Angel; Sempere-Payá, Víctor M
2016-04-29
Ultrasound diagnosis is a widely used medical tool. Among the various ultrasound techniques, ultrasonic imaging is particularly relevant. This paper presents an improvement to a two-dimensional (2D) ultrasonic system using measurements taken from perpendicular planes, where digital signal processing techniques are used to combine one-dimensional (1D) A-scans were acquired by individual transducers in arrays located in perpendicular planes. An algorithm used to combine measurements is improved based on the wavelet transform, which includes a denoising step during the 2D representation generation process. The inclusion of this new denoising stage generates higher quality 2D representations with a reduced level of speckling. The paper includes different 2D representations obtained from noisy A-scans and compares the improvements obtained by including the denoising stage.
Speckle variance optical coherence tomography of blood flow in the beating mouse embryonic heart.
Grishina, Olga A; Wang, Shang; Larina, Irina V
2017-05-01
Efficient separation of blood and cardiac wall in the beating embryonic heart is essential and critical for experiment-based computational modelling and analysis of early-stage cardiac biomechanics. Although speckle variance optical coherence tomography (SV-OCT) relying on calculation of intensity variance over consecutively acquired frames is a powerful approach for segmentation of fluid flow from static tissue, application of this method in the beating embryonic heart remains challenging because moving structures generate SV signal indistinguishable from the blood. Here, we demonstrate a modified four-dimensional SV-OCT approach that effectively separates the blood flow from the dynamic heart wall in the beating mouse embryonic heart. The method takes advantage of the periodic motion of the cardiac wall and is based on calculation of the SV signal over the frames corresponding to the same phase of the heartbeat cycle. Through comparison with Doppler OCT imaging, we validate this speckle-based approach and show advantages in its insensitiveness to the flow direction and velocity as well as reduced influence from the heart wall movement. This approach has a potential in variety of applications relying on visualization and segmentation of blood flow in periodically moving structures, such as mechanical simulation studies and finite element modelling. Picture: Four-dimensional speckle variance OCT imaging shows the blood flow inside the beating heart of an E8.5 mouse embryo. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Design and Construction of Detector and Data Acquisition Elements for Proton Computed Tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fermi Research Alliance; Northern Illinois University
2015-07-15
Proton computed tomography (pCT) offers an alternative to x-ray imaging with potential for three-dimensional imaging, reduced radiation exposure, and in-situ imaging. Northern Illinois University (NIU) is developing a second-generation proton computed tomography system with a goal of demonstrating the feasibility of three-dimensional imaging within clinically realistic imaging times. The second-generation pCT system is comprised of a tracking system, a calorimeter, data acquisition, a computing farm, and software algorithms. The proton beam encounters the upstream tracking detectors, the patient or phantom, the downstream tracking detectors, and a calorimeter. The schematic layout of the PCT system is shown. The data acquisition sendsmore » the proton scattering information to an offline computing farm. Major innovations of the second generation pCT project involve an increased data acquisition rate ( MHz range) and development of three-dimensional imaging algorithms. The Fermilab Particle Physics Division and Northern Illinois Center for Accelerator and Detector Development at Northern Illinois University worked together to design and construct the tracking detectors, calorimeter, readout electronics and detector mounting system.« less
NASA Astrophysics Data System (ADS)
Andersen, L.; Jones, C. J. C.
2006-06-01
The analysis of vibration from railway tunnels is of growing interest as new and higher-speed railways are built under the ground to address the transport problems of growing modern urban areas. Such analysis can be carried out using numerical methods but models and therefore computing times can be large. There is a need to be able to apply very fast calculations that can be used in tunnel design and studies of environmental impacts. Taking advantage of the fact that tunnels often have a two-dimensional geometry in the sense that the cross section is constant along the tunnel axis, it is useful to evaluate the potential uses of two-dimensional models before committing to much more costly three-dimensional approaches. The vibration forces in the track due to the passage of a train are by nature three-dimensional and a complete analysis undoubtedly requires a model of three-dimensional wave propagation. The aim of this paper is to investigate the quality of the information that can be gained from a two-dimensional model of a railway tunnel. The vibration transmission from the tunnel floor to the ground surface is analysed for the frequency range relevant to the perception of whole body vibration (about 4-80 Hz). A coupled finite element and boundary element scheme is applied in both two and three dimensions. Two tunnel designs are considered: a cut-and-cover tunnel for a double track and a single-track tunnel dug with the New Austrian tunnelling method (NATM).
Fetal myocardial deformation in maternal diabetes mellitus and obesity.
Kulkarni, A; Li, L; Craft, M; Nanda, M; Lorenzo, J M M; Danford, D; Kutty, S
2017-05-01
Experimental evidence suggests that changes in the fetal myocardium result from intrauterine effects of maternal diabetes mellitus and obesity. The aim of this study was to assess fetal cardiac function using two-dimensional speckle-tracking echocardiography to determine the effects of maternal diabetes and obesity on the fetal myocardium. Comparative cross-sectional evaluation of myocardial function in fetuses of mothers with diabetes mellitus (FDM) or obesity (FO) and normal gestational age-matched control fetuses (FC) was performed using two-dimensional speckle-tracking echocardiography at two centers. In total, 178 fetuses (82 FDM, 26 FO and 70 FC) met the enrolment criteria. Mean gestational age at assessment was similar among groups: 25.3 ± 5.1 weeks for FDM, 25.0 ± 4.6 weeks for FO and 25.1 ± 4.9 weeks for FC. Mean maternal body mass index was significantly higher in FDM and FO groups compared with the FC group. Statistically significant differences in fetal cardiac function were detected between FDM and FC for global longitudinal strain (mean ± SD, -21.4 ± 6.5% vs -27.0 ± 5.2%; P < 0.001), global circumferential strain (mean ± SD, -22.6 ± 6.5% vs -26.2 ± 6.8%; P = 0.002), average longitudinal systolic strain rate (median, -1.4 (interquartile range (IQR), -1.7 to -1.1)/s vs -1.6 (IQR, -2.0 to -1.4)/s; P = 0.001) and average circumferential systolic strain rate (median, -1.4 (IQR, -1.9 to -1.1)/s vs -1.6 (IQR, -2.1 to -1.3)/s; P = 0.006). Cases of non-obese FDM also had abnormal strain parameters compared with FC. Global longitudinal strain (mean ± SD, -21.1 ± 7.5%) and average circumferential systolic strain rate (median, -1.3 (IQR, -1.8 to -1.1)/s) were significantly lower in FO compared with FC. Unfavorable changes occur in the fetal myocardium in response to both maternal diabetes mellitus and obesity. The long-term prognostic implications of these changes require further study. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Malakan Rad, Elaheh; Ghandi, Yazdan; Kocharian, Armen; Mirzaaghayan, Mohammadreza
2016-01-01
Background: The late postoperative course for children with transposition of the great arteries (TGA) with an intact ventricular septum (IVS) is very important because the coronary arteries may be at risk of damage during arterial switch operation (ASO). We sought to investigate left ventricular function in patients with TGA/IVS by echocardiography. Methods: From March 2011 to December 2012, totally 20 infants (12 males and 8 females) with TGA/IVS were evaluated via 2-dimensional speckle-tracking echocardiography (2D STE) more than 6 months after they underwent ASO. A control group of age-matched infants and children was also studied. Left ventricular longitudinal strain (S), strain rate (SR), time to peak systolic longitudinal strain (TPS), and time to peak systolic longitudinal strain rate (TPSR) were measured and compared between the 2 groups. Results: Mean ± SD of age at the time of study in the patients with TGA/IVS was 15 ± 5 months, and also age at the time of ASO was 12 ± 3 days. Weight was 3.13 ± 0.07 kg at birth and 8.83 ± 1.57 kg at the time of ASO. Global strain (S), Time to peak strain rate (TPSR), and Time to peak strain (TPS) were not significantly different between the 2 groups, whereas global strain rate (SR) was significantly different (p value < 0.001). In the 3-chamber view, the values of S in the lateral, septal, inferior, and anteroseptal walls were significantly different between the 2 groups (p value < 0.001), and SR in the posterior wall was significantly different between the 2 groups (p value < 0.001). There were no positive correlations between S and SR in terms of the variables of heart rate, total cardiopulmonary bypass time, and aortic cross-clamp time. There were no statistically significant differences between the 2 groups regarding S, SR, TPS, and TPSR in the anteroseptal and posterior walls in the 3-chamber view and in the lateral and septal walls in the 4-chamber view. Conclusion: We showed that between 6 and 18 months after a successful ASO, the parameters of S, SR, and global TPS were normal in our patients with TGA/IVS. However, LV myocardial TPSR did not normalize in this time period. PMID:27956909
Malakan Rad, Elaheh; Ghandi, Yazdan; Kocharian, Armen; Mirzaaghayan, Mohammadreza
2016-07-06
Background: The late postoperative course for children with transposition of the great arteries (TGA) with an intact ventricular septum (IVS) is very important because the coronary arteries may be at risk of damage during arterial switch operation (ASO). We sought to investigate left ventricular function in patients with TGA/IVS by echocardiography. Methods: From March 2011 to December 2012, totally 20 infants (12 males and 8 females) with TGA/IVS were evaluated via 2-dimensional speckle-tracking echocardiography (2D STE) more than 6 months after they underwent ASO. A control group of age-matched infants and children was also studied. Left ventricular longitudinal strain (S), strain rate (SR), time to peak systolic longitudinal strain (TPS), and time to peak systolic longitudinal strain rate (TPSR) were measured and compared between the 2 groups. Results: Mean ± SD of age at the time of study in the patients with TGA/IVS was 15 ± 5 months, and also age at the time of ASO was 12 ± 3 days. Weight was 3.13 ± 0.07 kg at birth and 8.83 ± 1.57 kg at the time of ASO. Global strain (S), Time to peak strain rate (TPSR), and Time to peak strain (TPS) were not significantly different between the 2 groups, whereas global strain rate (SR) was significantly different (p value < 0.001). In the 3-chamber view, the values of S in the lateral, septal, inferior, and anteroseptal walls were significantly different between the 2 groups (p value < 0.001), and SR in the posterior wall was significantly different between the 2 groups (p value < 0.001). There were no positive correlations between S and SR in terms of the variables of heart rate, total cardiopulmonary bypass time, and aortic cross-clamp time. There were no statistically significant differences between the 2 groups regarding S, SR, TPS, and TPSR in the anteroseptal and posterior walls in the 3-chamber view and in the lateral and septal walls in the 4-chamber view. Conclusion: We showed that between 6 and 18 months after a successful ASO, the parameters of S, SR, and global TPS were normal in our patients with TGA/IVS. However, LV myocardial TPSR did not normalize in this time period.
Leal, G N; Silva, K F; França, C M P; Lianza, A C; Andrade, J L; Campos, L M A; Bonfá, E; Silva, C A
2015-05-01
The objective of this article is to evaluate right ventricle strain imaging by two-dimensional speckle-tracking (2DST) in childhood-onset systemic lupus erythematosus (c-SLE). Thirty-five c-SLE patients with no signs or symptoms of heart failure and 33 healthy volunteers were evaluated by standard echocardiogram and 2DST. Conventional parameters included tricuspid annular plane systolic excursion (TAPSE), RV tissue-Doppler-derived Tei index and systolic pulmonary artery pressure. Global peak longitudinal systolic strain (PLSS) and strain rate (PLSSR) of RV were obtained by 2DST. Demographic/clinical features, SLEDAI-2K/SLICC/ACR-DI and treatment were also assessed. The median current age was similar in patients and controls (14.75 vs. 14.88 years, p = 0.62). RV PLSS was significantly reduced in c-SLE (-24.5 ± 5.09 vs. -27.62 ± 3.02%, p = 0.003). Similar findings were observed after excluding patients with pulmonary hypertension (-24.62 ± 4.87% vs. -27.62 ± 3.02%, p = 0.0041). RV PLSS was positively correlated with TAPSE (r = +0.49, p = 0.0027) and negatively correlated with Tei index (r = -0.34, p = 0.04) in c-SLE. RV PLSSR was not different comparing patients and controls (-0.65 s(-1 )± 0.47 vs. -1.87 ± 0.49 s(-1), p = 0.07). Further analysis of c-SLE patients revealed higher frequencies of neuropsychiatric manifestations (39% vs. 0%, p = 0.007) and antiphospholipid antibodies (55% vs. 18%, p = 0.035) in those with RV PLSS ≤ -23.7% vs >-23.7%. No differences were evidenced in demographic data, disease activity/damage or treatments (p > 0.05). The present study, using a new and more sensitive technique, revealed subclinical RV systolic dysfunction in c-SLE patients that may have future prognostic implications. The novel association of asymptomatic RV dysfunction with neuropsychiatric manifestations and antiphospholipid antibodies may suggest common physiopathological pathways. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
A photophoretic-trap volumetric display
NASA Astrophysics Data System (ADS)
Smalley, D. E.; Nygaard, E.; Squire, K.; van Wagoner, J.; Rasmussen, J.; Gneiting, S.; Qaderi, K.; Goodsell, J.; Rogers, W.; Lindsey, M.; Costner, K.; Monk, A.; Pearson, M.; Haymore, B.; Peatross, J.
2018-01-01
Free-space volumetric displays, or displays that create luminous image points in space, are the technology that most closely resembles the three-dimensional displays of popular fiction. Such displays are capable of producing images in ‘thin air’ that are visible from almost any direction and are not subject to clipping. Clipping restricts the utility of all three-dimensional displays that modulate light at a two-dimensional surface with an edge boundary; these include holographic displays, nanophotonic arrays, plasmonic displays, lenticular or lenslet displays and all technologies in which the light scattering surface and the image point are physically separate. Here we present a free-space volumetric display based on photophoretic optical trapping that produces full-colour graphics in free space with ten-micrometre image points using persistence of vision. This display works by first isolating a cellulose particle in a photophoretic trap created by spherical and astigmatic aberrations. The trap and particle are then scanned through a display volume while being illuminated with red, green and blue light. The result is a three-dimensional image in free space with a large colour gamut, fine detail and low apparent speckle. This platform, named the Optical Trap Display, is capable of producing image geometries that are currently unobtainable with holographic and light-field technologies, such as long-throw projections, tall sandtables and ‘wrap-around’ displays.
Single-particle tracking of quantum dot-conjugated prion proteins inside yeast cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsuji, Toshikazu; Kawai-Noma, Shigeko; Pack, Chan-Gi
2011-02-25
Research highlights: {yields} We develop a method to track a quantum dot-conjugated protein in yeast cells. {yields} We incorporate the conjugated quantum dot proteins into yeast spheroplasts. {yields} We track the motions by conventional or 3D tracking microscopy. -- Abstract: Yeast is a model eukaryote with a variety of biological resources. Here we developed a method to track a quantum dot (QD)-conjugated protein in the budding yeast Saccharomyces cerevisiae. We chemically conjugated QDs with the yeast prion Sup35, incorporated them into yeast spheroplasts, and tracked the motions by conventional two-dimensional or three-dimensional tracking microscopy. The method paves the way towardmore » the individual tracking of proteins of interest inside living yeast cells.« less
Aguilar, Frank G; Selvaraj, Senthil; Martinez, Eva E; Katz, Daniel H; Beussink, Lauren; Kim, Kwang-Youn A; Ping, Jie; Rasmussen-Torvik, Laura; Goyal, Amita; Sha, Jin; Irvin, Marguerite R; Arnett, Donna K; Shah, Sanjiv J
2016-03-01
Several large epidemiologic studies and clinical trials have included echocardiography, but images were stored in analog format and these studies predated tissue Doppler imaging (TDI) and speckle tracking echocardiography (STE). We hypothesized that digitization of analog echocardiograms, with subsequent quantification of cardiac mechanics using STE, is feasible, reproducible, accurate, and produces clinically valid results. In the NHLBI HyperGEN study (N = 2234), archived analog echocardiograms were digitized and subsequently analyzed using STE to obtain tissue velocities/strain. Echocardiograms were assigned quality scores and inter-/intra-observer agreement was calculated. Accuracy was evaluated in: (1) a separate second study (N = 50) comparing prospective digital strain versus post hoc analog-to-digital strain, and (2) in a third study (N = 95) comparing prospectively obtained TDI e' velocities with post hoc STE e' velocities. Finally, we replicated previously known associations between tissue velocities/strain, conventional echocardiographic measurements, and clinical data. Of the 2234 HyperGEN echocardiograms, 2150 (96.2%) underwent successful digitization and STE analysis. Inter/intra-observer agreement was high for all STE parameters, especially longitudinal strain (LS). In accuracy studies, LS performed best when comparing post hoc STE to prospective digital STE for strain analysis. STE-derived e' velocities correlated with, but systematically underestimated, TDI e' velocity. Several known associations between clinical variables and cardiac mechanics were replicated in HyperGEN. We also found a novel independent inverse association between fasting glucose and LS (adjusted β = -2.4 [95% CI -3.6, -1.2]% per 1-SD increase in fasting glucose; P < 0.001). Archeological echocardiography, the digitization and speckle tracking analysis of archival echocardiograms, is feasible and generates indices of cardiac mechanics similar to contemporary studies. © 2015, Wiley Periodicals, Inc.
Aguilar, Frank G.; Selvaraj, Senthil; Martinez, Eva E.; Katz, Daniel H.; Beussink, Lauren; Kim, Kwang-Youn A.; Ping, Jie; Rasmussen-Torvik, Laura; Goyal, Amita; Sha, Jin; Irvin, Marguerite R.; Arnett, Donna K.; Shah, Sanjiv J.
2015-01-01
Background Several large epidemiologic studies and clinical trials have included echocardiography, but images were stored in analog format and these studies predated tissue Doppler imaging (TDI) and speckle-tracking echocardiography (STE). We hypothesized that digitization of analog echocardiograms, with subsequent quantification of cardiac mechanics using STE, is feasible, reproducible, accurate, and produces clinically valid results. Methods In the NHLBI HyperGEN study (N=2234), archived analog echocardiograms were digitized and subsequently analyzed using STE to obtain tissue velocities/strain. Echocardiograms were assigned quality scores and inter/intraobserver agreement was calculated. Accuracy was evaluated in (1) a separate second study (N=50) comparing prospective digital strain vs. post-hoc analog-to-digital strain; and (2) in a third study (N=95) comparing prospectively-obtained TDI e′ velocities with post-hoc STE e′ velocities. Finally, we replicated previously known associations between tissue velocities/strain, conventional echocardiographic measurements, and clinical data. Results Of the 2234 HyperGEN echocardiograms, 2150 (96.2%) underwent successful digitization and STE analysis. Inter/intraobserver agreement was high for all STE parameters, especially longitudinal strain (LS). In accuracy studies, LS performed best when comparing post-hoc STE to prospective digital STE for strain analysis. STE-derived e′ velocities correlated with, but systematically underestimated, TDI e′ velocity. Several known associations between clinical variables and cardiac mechanics were replicated in HyperGEN. We also found a novel independent inverse association between fasting glucose and LS (adjusted β =−2.4 [95% CI −3.6,−1.2]% per 1-SD increase in fasting glucose; P<0.001). Conclusions Archeological echocardiography, the digitization and speckle-tracking analysis of archival echocardiograms, is feasible and generates parameters of cardiac mechanics similar to contemporary studies. PMID:26525308
Sengupta, Partho P; Huang, Yen-Min; Bansal, Manish; Ashrafi, Ali; Fisher, Matt; Shameer, Khader; Gall, Walt; Dudley, Joel T
2016-06-01
Associating a patient's profile with the memories of prototypical patients built through previous repeat clinical experience is a key process in clinical judgment. We hypothesized that a similar process using a cognitive computing tool would be well suited for learning and recalling multidimensional attributes of speckle tracking echocardiography data sets derived from patients with known constrictive pericarditis and restrictive cardiomyopathy. Clinical and echocardiographic data of 50 patients with constrictive pericarditis and 44 with restrictive cardiomyopathy were used for developing an associative memory classifier-based machine-learning algorithm. The speckle tracking echocardiography data were normalized in reference to 47 controls with no structural heart disease, and the diagnostic area under the receiver operating characteristic curve of the associative memory classifier was evaluated for differentiating constrictive pericarditis from restrictive cardiomyopathy. Using only speckle tracking echocardiography variables, associative memory classifier achieved a diagnostic area under the curve of 89.2%, which improved to 96.2% with addition of 4 echocardiographic variables. In comparison, the area under the curve of early diastolic mitral annular velocity and left ventricular longitudinal strain were 82.1% and 63.7%, respectively. Furthermore, the associative memory classifier demonstrated greater accuracy and shorter learning curves than other machine-learning approaches, with accuracy asymptotically approaching 90% after a training fraction of 0.3 and remaining flat at higher training fractions. This study demonstrates feasibility of a cognitive machine-learning approach for learning and recalling patterns observed during echocardiographic evaluations. Incorporation of machine-learning algorithms in cardiac imaging may aid standardized assessments and support the quality of interpretations, particularly for novice readers with limited experience. © 2016 American Heart Association, Inc.
Miller, Brian; Dawson, Stephen; Vennell, Ross
2013-10-01
Observations are presented of the vocal behavior and three dimensional (3D) underwater movements of sperm whales measured with a passive acoustic array off the coast of Kaikoura, New Zealand. Visual observations and vocal behaviors of whales were used to divide dive tracks into different phases, and depths and movements of whales are reported for each of these phases. Diving depths and movement information from 75 3D tracks of whales in Kaikoura are compared to one and two dimensional tracks of whales studied in other oceans. While diving, whales in Kaikoura had a mean swimming speed of 1.57 m/s, and, on average, dived to a depth of 427 m (SD = 117 m), spending most of their time at depths between 300 and 600 m. Creak vocalizations, assumed to be the prey capture phase of echolocation, occurred throughout the water column from sea surface to sea floor, but most occurred at depths of 400-550 m. Three dimensional measurement of tracking revealed several different "foraging" strategies, including active chasing of prey, lining up slow-moving or unsuspecting prey, and foraging on demersal or benthic prey. These movements provide the first 3D descriptions underwater behavior of whales at Kaikoura.
Three-dimensional particle tracking velocimetry using dynamic vision sensors
NASA Astrophysics Data System (ADS)
Borer, D.; Delbruck, T.; Rösgen, T.
2017-12-01
A fast-flow visualization method is presented based on tracking neutrally buoyant soap bubbles with a set of neuromorphic cameras. The "dynamic vision sensors" register only the changes in brightness with very low latency, capturing fast processes at a low data rate. The data consist of a stream of asynchronous events, each encoding the corresponding pixel position, the time instant of the event and the sign of the change in logarithmic intensity. The work uses three such synchronized cameras to perform 3D particle tracking in a medium sized wind tunnel. The data analysis relies on Kalman filters to associate the asynchronous events with individual tracers and to reconstruct the three-dimensional path and velocity based on calibrated sensor information.
NASA Astrophysics Data System (ADS)
Cho, Hoonkyung; Chun, Joohwan; Song, Sungchan
2016-09-01
The dim moving target tracking from the infrared image sequence in the presence of high clutter and noise has been recently under intensive investigation. The track-before-detect (TBD) algorithm processing the image sequence over a number of frames before decisions on the target track and existence is known to be especially attractive in very low SNR environments (⩽ 3 dB). In this paper, we shortly present a three-dimensional (3-D) TBD with dynamic programming (TBD-DP) algorithm using multiple IR image sensors. Since traditional two-dimensional TBD algorithm cannot track and detect the along the viewing direction, we use 3-D TBD with multiple sensors and also strictly analyze the detection performance (false alarm and detection probabilities) based on Fisher-Tippett-Gnedenko theorem. The 3-D TBD-DP algorithm which does not require a separate image registration step uses the pixel intensity values jointly read off from multiple image frames to compute the merit function required in the DP process. Therefore, we also establish the relationship between the pixel coordinates of image frame and the reference coordinates.
Aroditis, K; Pikilidou, M; Vourvouri, E; Hadjistavri, L; Zebekakis, P; Yovos, J; Efthimiadis, G; Karvounis, H
2017-02-01
Overproduction of thyroid hormones leads to structural as well as functional cardiac changes. Conventional echocardiography but also recently developed sophisticated two-dimensional echocardiography speckle (2D-STE) tracking allow elaborate evaluation of these changes. Our purpose was to investigate the effects of thyroid hormones overproduction on the heart in patients with Graves' disease and changes that occur after 6 months thyrostatic therapy. We conducted a prospective, case-control study of 6 months duration. Full echocardiographic assessment at diagnosis and after 6 months of thyrostatic therapy were performed in 44 patients with Graves' disease, aged 37.6 ± 9.1 years. Additionally, 43 euthyroid controls were studied for the same time period. Left ventricular end diastolic diameter (LVEDD) and left ventricular end systolic diameter (LVESD) were higher in the patient group while triscupid annular plane systolic excursion (TAPSE) was lower in the patient group. Moreover, left ventricular (LV) mass index and left atrium (LA) volume index were higher in the Graves' disease group. Diastolic impairment as assessed with conventional echocardiography including tissue Doppler was present in the patient group (E/A ratio 0.87 ± 0.10,). 2D-STE analysis, revealed an increase in the strain rate at the isovolumic relaxation time (SRIVRT, 0.310 ± 0.07 patients versus 0.298 ± 0.09 s -1 controls). Improvement in diastolic and right systolic function as well as in left ventricular structural parameters was observed after restoration of euthyroidism (E/A ratio from 0.87 ± 0.10 versus 0.9 ± 0.08, p < 0.05). Patients with newly diagnosed Graves' showed an improvement in diastolic function, right systolic function and structural parameters after 6 months of thyrostatic treatment.
Timóteo, Ana T; Branco, Luísa M; Rosa, Sílvia A; Ramos, Ruben; Agapito, Ana F; Sousa, Lídia; Galrinho, Ana; Oliveira, José A; Oliveira, Mário M; Ferreira, Rui C
2017-01-01
To determine whether right ventricular and/or atrial speckle tracking strain is associated with previous arrhythmic events in patients with repaired tetralogy of Fallot. We studied right ventricular and atrial strain in 100 consecutive patients with repaired tetralogy of Fallot referred for routine echocardiographic evaluation. Patients were divided into two groups, one with previous documentation of arrhythmias (n=26) and one without arrhythmias, in a median follow-up of 22 years. Patients with arrhythmias were older (p<0.001) and had surgical repair at an older age (p=0.001). They also had significantly reduced right ventricular strain (-14.7±5.5 vs. -16.9±4.0%, p=0.029) and right atrial strain (19.1±7.7% vs. 25.8±11.4%, p=0.001). Neither right ventricular nor right atrial strain were independent predictors of the presence of a history of documented arrhythmias, which was associated with age at correction and with the presence of residual defects. In a subanalysis after excluding 23 patients who had had more than one corrective surgery, right ventricular strain was an independent predictor of the presence of previous arrhythmic events (OR 1.19, 95% CI 1.02-1.38, p=0.025). Right atrial strain was also an independent predictor after adjustment (OR 0.93, 95% CI 0.87-0.99, p=0.029). The ideal cut-off for right ventricular strain was -15.3% and for right atrial strain 23.0%. Compared with conventional echocardiographic parameters, strain measures of the right heart are associated with the presence of arrhythmic events, and may be useful for risk stratification of patients with repaired tetralogy of Fallot, although a prospective study is required. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.
Gulel, Okan; Akcay, Murat; Soylu, Korhan; Aksan, Gokhan; Yuksel, Serkan; Zengin, Halit; Meric, Murat; Sahin, Mahmut
2016-05-01
The coronary slow flow phenomenon (CSFP) is defined as a delayed distal vessel contrast opacification in the absence of obstructive epicardial coronary artery disease during coronary angiography. There is conflicting data in medical literature regarding the effects of CSFP on the left ventricular functions assessed by conventional echocardiography or tissue Doppler imaging. Therefore, we aimed to evaluate whether there is any abnormality in the myocardial deformation parameters (strain, strain rate (SR), rotation, twist) of the left ventricle obtained by speckle tracking echocardiography (STE) in patients with CSFP. Twenty patients with CSFP were included prospectively in the study. Another 20 patients with similar demographics and cardiovascular risk factors as well as normal coronary angiography were used as the control group. Two-dimensional echocardiographic images of the left ventricle from the apical long-axis, two-chamber, four-chamber, and parasternal short-axis views were used for STE analysis. The analysis of left ventricular circumferential deformation parameters showed that the averaged peak systolic strain, systolic SR, and early diastolic SR values were significantly lower in patients with CSFP (P = 0.009, P = 0.02, and P = 0.02, respectively). Among the left ventricular rotation and twist values, apical rotation was significantly lower in patients with CSFP (P = 0.02). Further, the mean thrombolysis in myocardial infarction frame count value was found to be negatively correlated with the averaged peak circumferential early diastolic SR (r = -0.35, P = 0.03). It was positively correlated with the averaged peak circumferential systolic strain (r = 0.47, P = 0.003) and circumferential systolic SR (r = 0.46, P = 0.005). Coronary slow flow phenomenon leads to significant alterations in the myocardial deformation parameters of the left ventricle as assessed by STE. Specifically, circumferential deformation parameters are affected in CSFP patients. © 2015, Wiley Periodicals, Inc.
Spinelli, Letizia; Imbriaco, Massimo; Nappi, Carmela; Nicolai, Emanuele; Giugliano, Giuseppe; Ponsiglione, Andrea; Diomiaiuti, Tommaso Claudio; Riccio, Eleonora; Duro, Giovanni; Pisani, Antonio; Trimarco, Bruno; Cuocolo, Alberto
2018-04-01
Hybrid 18 F-fluorodeoxyglucose (FDG) positron emission tomography and magnetic resonance imaging may differentiate mature fibrosis or scar from fibrosis associated to active inflammation in patients with Anderson-Fabry disease, even in nonhypertrophic stage. This study was designed to compare the results of positron emission tomography and magnetic resonance cardiac imaging with those of speckle-tracking echocardiography in heterozygous Anderson-Fabry disease females. Twenty-four heterozygous females carrying α-galactosidase A mutation and without left ventricular hypertrophy underwent cardiac positron emission tomography and magnetic resonance using 18 F-FDG for glucose uptake and 2-dimensional strain echocardiography. 18 F-FDG myocardial uptake was quantified by measuring the coefficient of variation (COV) of the standardized uptake value using a 17-segment model. Focal 18 F-FDG uptake with COV >0.17 was detected in 13 patients, including 2 patients with late gadolinium enhancement at magnetic resonance. COV was 0.30±0.14 in patients with focal 18 F-FDG uptake and 0.12±0.03 in those without ( P <0.001). Strain echocardiography revealed worse global longitudinal systolic strain in patients with COV >0.17 compared with those with COV ≤0.17 (-18.5±2.7% versus -22.2±1.8%; P =0.024). For predicting COV >0.17, a global longitudinal strain >-19.8% had 77% sensitivity and 91% specificity and a value >2 dysfunctional segments 92% sensitivity and 100% specificity. In females carrying α-galactosidase A mutation, focal 18 F-FDG uptake represents an early sign of disease-related myocardial damage and is associated with impaired left ventricular longitudinal function. These findings support the hypothesis that inflammation plays an important role in glycosphingolipids storage disorders. © 2018 American Heart Association, Inc.
Eleid, Mackram F; Caracciolo, Giuseppe; Cho, Eun Joo; Scott, Robert L; Steidley, D Eric; Wilansky, Susan; Arabia, Francisco A; Khandheria, Bijoy K; Sengupta, Partho P
2010-10-01
The aim of this study was to explore the temporal evolution of left ventricular (LV) mechanics in relation to clinical variables and genetic expression profiles implicated in cardiac allograft function. Considerable uncertainty exists regarding the range and determinants of variability in LV systolic performance in transplanted hearts (TXH). Fifty-one patients (mean age 53 ± 12 years; 37 men) underwent serial assessment of echocardiograms, cardiac catheterization, gene expression profiles, and endomyocardial biopsy data within 2 weeks and at 3, 6, 12, and 24 months after transplantation. Two-dimensional speckle-tracking data were compared between patients with TXH and 37 controls (including 12 post-coronary artery bypass patients). Post-transplantation mortality and hospitalizations were recorded with a median follow-up period of 944 days. Global longitudinal strain (LS) and radial strain remained attenuated in patients with TXH at all time points (p < 0.001 and p = 0.005), independent of clinical rejection episodes. Failure to improve global LS at 3 months (≥ 1 SD) was associated with higher incidence of death and cardiac events (hazard ratio: 5.92; 95% confidence interval: 1.96 to 17.91; p = 0.049). Multivariate analysis revealed gene expression score as the only independent predictor of global LS (R(2) = 0.53, p = 0.005), with SEMA7A gene expression having the highest correlation with global LS (r = -0.84, p < 0.001). Speckle tracking-derived LV strains are helpful in estimating the burden of LV dysfunction in patients with TXH that evolves independent of biopsy-detected cellular rejection. Failure to improve global LS at 3 months after transplantation is associated with a higher incidence of death and cardiac events. Serial changes in LV mechanics correlate with peripheral blood gene expression profiles and may affect the clinical assessment of long-term prognosis in patients with TXH. Copyright © 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Pirat, Bahar; Bozbas, Huseyin; Simsek, Vahide; Sade, L Elif; Sayin, Burak; Muderrisoglu, Haldun; Haberal, Mehmet
2015-04-01
Velocity vector imaging allows quantitation of myocardial strain and strain rate from 2-dimensional images based on speckle tracking echocardiography. The aim of this study was to analyze the changes in myocardial strain and strain rate patterns in patients with end-stage renal disease and renal transplant recipients. We studied 33 patients with end-stage renal disease on hemodialysis (19 men; mean age, 36 ± 8 y), 24 renal transplant recipients with functional grafts (21 men; mean age, 36 ± 7 y) and 26 age- and sex-matched control subjects. Longitudinal peak systolic strain and strain rate for basal, mid, and apical segments of the left ventricular wall were determined by velocity vector imaging from apical 4- and 2-chamber views. The average longitudinal strain and strain rate for the left ventricle were noted. From short-axis views at the level of papillary muscles, average circumferential, and radial strain, and strain rate were assessed. Mean heart rate and systolic and diastolic blood pressure during imaging were similar between the groups. Longitudinal peak systolic strain and strain rate at basal and mid-segments of the lateral wall were significantly higher in renal transplant recipients and control groups than endstage renal disease patients. Average longitudinal systolic strain from the 4-chamber view was highest in control subjects (-14.5% ± 2.9%) and was higher in renal transplant recipients (-12.5% ± 3.0%) than end-stage renal disease patients (-10.2% ± 1.6%; P ≤ .001). Radial and circumferential strain and strain rate at the level of the papillary muscle were lower in patients with end-stage renal disease than other groups. Differences in myocardial function in patients with end-stage renal disease, renal transplant recipients, and normal controls can be quantified by strain imaging. Myocardial function is improved in renal transplant recipients compared with end-stage renal disease patients.
Understanding the exposure-time effect on speckle contrast measurements for laser displays
NASA Astrophysics Data System (ADS)
Suzuki, Koji; Kubota, Shigeo
2018-02-01
To evaluate the influence of exposure time on speckle noise for laser displays, speckle contrast measurement method was developed observable at a human eye response time using a high-sensitivity camera which has a signal multiplying function. The nonlinearity of camera light sensitivity was calibrated to measure accurate speckle contrasts, and the measuring lower limit noise of speckle contrast was improved by applying spatial-frequency low pass filter to the captured images. Three commercially available laser displays were measured over a wide range of exposure times from tens of milliseconds to several seconds without adjusting the brightness of laser displays. The speckle contrast of raster-scanned mobile projector without any speckle-reduction device was nearly constant over various exposure times. On the contrary to this, in full-frame projection type laser displays equipped with a temporally-averaging speckle-reduction device, some of their speckle contrasts close to the lower limits noise were slightly increased at the shorter exposure time due to the noise. As a result, the exposure-time effect of speckle contrast could not be observed in our measurements, although it is more reasonable to think that the speckle contrasts of laser displays, which are equipped with the temporally-averaging speckle-reduction device, are dependent on the exposure time. This discrepancy may be attributed to the underestimation of temporal averaging factor. We expected that this method is useful for evaluating various laser displays and clarify the relationship between the speckle noise and the exposure time for a further verification of speckle reduction.
NASA Technical Reports Server (NTRS)
Barranger, John P.
1990-01-01
A novel optical method of measuring 2-D surface strain is proposed. Two linear strains along orthogonal axes and the shear strain between those axes is determined by a variation of Yamaguchi's laser-speckle strain gage technique. It offers the advantages of shorter data acquisition times, less stringent alignment requirements, and reduced decorrelation effects when compared to a previously implemented optical strain rosette technique. The method automatically cancels the translational and rotational components of rigid body motion while simplifying the optical system and improving the speed of response.
FPGA Implementation of the Coupled Filtering Method and the Affine Warping Method.
Zhang, Chen; Liang, Tianzhu; Mok, Philip K T; Yu, Weichuan
2017-07-01
In ultrasound image analysis, the speckle tracking methods are widely applied to study the elasticity of body tissue. However, "feature-motion decorrelation" still remains as a challenge for the speckle tracking methods. Recently, a coupled filtering method and an affine warping method were proposed to accurately estimate strain values, when the tissue deformation is large. The major drawback of these methods is the high computational complexity. Even the graphics processing unit (GPU)-based program requires a long time to finish the analysis. In this paper, we propose field-programmable gate array (FPGA)-based implementations of both methods for further acceleration. The capability of FPGAs on handling different image processing components in these methods is discussed. A fast and memory-saving image warping approach is proposed. The algorithms are reformulated to build a highly efficient pipeline on FPGA. The final implementations on a Xilinx Virtex-7 FPGA are at least 13 times faster than the GPU implementation on the NVIDIA graphic card (GeForce GTX 580).
A local crack-tracking strategy to model three-dimensional crack propagation with embedded methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Annavarapu, Chandrasekhar; Settgast, Randolph R.; Vitali, Efrem
We develop a local, implicit crack tracking approach to propagate embedded failure surfaces in three-dimensions. We build on the global crack-tracking strategy of Oliver et al. (Int J. Numer. Anal. Meth. Geomech., 2004; 28:609–632) that tracks all potential failure surfaces in a problem at once by solving a Laplace equation with anisotropic conductivity. We discuss important modifications to this algorithm with a particular emphasis on the effect of the Dirichlet boundary conditions for the Laplace equation on the resultant crack path. Algorithmic and implementational details of the proposed method are provided. Finally, several three-dimensional benchmark problems are studied and resultsmore » are compared with available literature. Lastly, the results indicate that the proposed method addresses pathological cases, exhibits better behavior in the presence of closely interacting fractures, and provides a viable strategy to robustly evolve embedded failure surfaces in 3D.« less
A local crack-tracking strategy to model three-dimensional crack propagation with embedded methods
Annavarapu, Chandrasekhar; Settgast, Randolph R.; Vitali, Efrem; ...
2016-09-29
We develop a local, implicit crack tracking approach to propagate embedded failure surfaces in three-dimensions. We build on the global crack-tracking strategy of Oliver et al. (Int J. Numer. Anal. Meth. Geomech., 2004; 28:609–632) that tracks all potential failure surfaces in a problem at once by solving a Laplace equation with anisotropic conductivity. We discuss important modifications to this algorithm with a particular emphasis on the effect of the Dirichlet boundary conditions for the Laplace equation on the resultant crack path. Algorithmic and implementational details of the proposed method are provided. Finally, several three-dimensional benchmark problems are studied and resultsmore » are compared with available literature. Lastly, the results indicate that the proposed method addresses pathological cases, exhibits better behavior in the presence of closely interacting fractures, and provides a viable strategy to robustly evolve embedded failure surfaces in 3D.« less
A Novel Method for Tracking Individuals of Fruit Fly Swarms Flying in a Laboratory Flight Arena.
Cheng, Xi En; Qian, Zhi-Ming; Wang, Shuo Hong; Jiang, Nan; Guo, Aike; Chen, Yan Qiu
2015-01-01
The growing interest in studying social behaviours of swarming fruit flies, Drosophila melanogaster, has heightened the need for developing tools that provide quantitative motion data. To achieve such a goal, multi-camera three-dimensional tracking technology is the key experimental gateway. We have developed a novel tracking system for tracking hundreds of fruit flies flying in a confined cubic flight arena. In addition to the proposed tracking algorithm, this work offers additional contributions in three aspects: body detection, orientation estimation, and data validation. To demonstrate the opportunities that the proposed system offers for generating high-throughput quantitative motion data, we conducted experiments on five experimental configurations. We also performed quantitative analysis on the kinematics and the spatial structure and the motion patterns of fruit fly swarms. We found that there exists an asymptotic distance between fruit flies in swarms as the population density increases. Further, we discovered the evidence for repulsive response when the distance between fruit flies approached the asymptotic distance. Overall, the proposed tracking system presents a powerful method for studying flight behaviours of fruit flies in a three-dimensional environment.
NASA Astrophysics Data System (ADS)
Steig, Tracey W.; Timko, Mark A.
2005-04-01
Acoustic tags were used to monitor the swimming patterns of downstream migrating salmon smolts approaching various dams on the Columbia River, USA. Downstream migrating yearling chinook (Oncorhynchus tshawytscha), steelhead (Oncorhynchus mykiss), sockeye (Oncorhynchus nerka), and sub-yearling chinook smolts were surgically implanted with acoustic tags. Fish were tracked in three-dimensions as they approached and passed into the turbine intakes, spillways, and surface bypass channel entrances at the dams during the 2004 spring and summer outmigrations. A number of advances in the analysis techniques and software have been made over the past few years. Some of these improvements include the development of various fish density algorithms, stream trace modeling analysis, and advances of three-dimensional animation programs. Three-dimensional tracks of fish approaching the turbine intakes, spillways, and surface bypass channel entrances will be presented. Concentrations of fish passage will be presented as three-dimensional fish densities superimposed over dam structures. Stream trace modeling animation will be presented showing predicted fish passage routes.
Nunes, Maria Carmo P; Badano, Luigi Paolo; Marin-Neto, J Antonio; Edvardsen, Thor; Fernández-Golfín, Covadonga; Bucciarelli-Ducci, Chiara; Popescu, Bogdan A; Underwood, Richard; Habib, Gilbert; Zamorano, Jose Luis; Saraiva, Roberto Magalhães; Sabino, Ester Cerdeira; Botoni, Fernando A; Barbosa, Márcia Melo; Barros, Marcio Vinicius L; Falqueto, Eduardo; Simões, Marcus Vinicius; Schmidt, André; Rochitte, Carlos Eduardo; Rocha, Manoel Otávio Costa; Ribeiro, Antonio Luiz Pinho; Lancellotti, Patrizio
2018-04-01
To develop a document by Brazilian Cardiovascular Imaging Department (DIC) and the European Association of Cardiovascular Imaging (EACVI) to review and summarize the most recent evidences about the non-invasive assessment of patients with Chagas disease, with the intent to set up a framework for standardized cardiovascular imaging to assess cardiovascular morphologic and functional disturbances, as well as to guide the subsequent process of clinical decision-making. Chagas disease remains one of the most prevalent infectious diseases in Latin America, and has become a health problem in non-endemic countries. Dilated cardiomyopathy is the most severe manifestation of Chagas disease, which causes substantial disability and early mortality in the socially most productive population leading to a significant economical burden. Prompt and correct diagnosis of Chagas disease requires specialized clinical expertise to recognize the unique features of this disease. The appropriate and efficient use of cardiac imaging is pivotal for diagnosing the cardiac involvement in Chagas disease, to stage the disease, assess patients' prognosis and address management. Echocardiography is the most common imaging modality used to assess, and follow-up patients with Chagas disease. The presence of echocardiographic abnormalities is of utmost importance, since it allows to stage patients according to disease progression. In early stages of cardiac involvement, echocardiography may demonstrate segmental left ventricuar wall motion abnormalities, mainly in the basal segments of inferior, inferolateral walls, and the apex, which cannot be attributed to obstructive coronary artery arteries. The prevalence of segmental wall motion abnormalities varies according to the stage of the disease, reaching about 50% in patients with left ventricular dilatation and dysfunction. Speckle tracking echocardiography allows a more precise and quantitative measurement of the regional myocardial function. Since segmental wall motion abnormalities are frequent in Chagas disease, speckle tracking echocardiography may have an important clinical application in these patients, particularly in the indeterminate forms when abnormalities are more subtle. Speckle tracking echocardiography can also quantify the heterogeneity of systolic contraction, which is associated with the risk of arrhythmic events. Three-dimensional (3D) echocardiography is superior to conventional two-dimensional (2D) echocardiography for assessing more accurately the left ventricular apex and thus to detect apical aneurysms and thrombus in patients in whom ventricular foreshortening is suspected by 2D echocardiography. In addition, 3D echocardiography is more accurate than 2D Simpson s biplane rule for assessing left ventricular volumes and function in patients with significant wall motion abnormalities, including aneurysms with distorted ventricular geometry. Contrast echocardiography has the advantage to enhancement of left ventricular endocardial border, allowing for more accurate detection of ventricular aneurysms and thrombus in Chagas disease. Diastolic dysfunction is an important hallmark of Chagas disease even in its early phases. In general, left ventricular diastolic and systolic dysfunction coexist and isolated diastolic dysfunction is uncommon but may be present in patients with the indeterminate form. Right ventricular dysfunction may be detected early in the disease course, but in general, the clinical manifestations occur late at advanced stages of Chagas cardiomyopathy. Several echocardiographic parameters have been used to assess right ventricular function in Chagas disease, including qualitative evaluation, myocardial performance index, tissue Doppler imaging, tricuspid annular plane systolic excursion, and speckle tracking strain. Cardiac magnetic resonance (CMR) is useful to assess global and regional left ventricular function in patients with Chagas diseases. Myocardial fibrosis is a striking feature of Chagas cardiomyopathy and late gadolinium enhancement (LGE) is used to detect and quantify the extension of myocardial fibrosis. Myocardial fibrosis might have a role in risk stratification of patients with Chagas disease. Limited data are available regarding right ventricular function assessed by CMR in Chagas disease. Radionuclide ventriculography is used for global biventricular function assessment in patients with suspected or definite cardiac involvement in Chagas disease with suboptimal acoustic window and contraindication to CMR. Myocardial perfusion scintigraphy may improve risk stratification to define cardiac involvement in Chagas disease, especially in the patients with devices who cannot be submitted to CMR and in the clinical setting of Chagas patients whose main complaint is atypical chest pain. Detection of reversible ischemic defects predicts further deterioration of left ventricular systolic function and helps to avoid unnecessary cardiac catheterization and coronary angiography. Cardiac imaging is crucial to detect the cardiac involvement in patients with Chagas disease, stage the disease and stratify patient risk and address management. Unfortunately, most patients live in regions with limited access to imaging methods and point-of-care, simplified protocols, could improve the access of these remote populations to important information that could impact in the clinical management of the disease. Therefore, there are many fields for further research in cardiac imaging in Chagas disease. How to better provide an earlier diagnosis of cardiac involvement and improve patients risk stratification remains to be addressed using different images modalities.
Left atrial physiology and pathophysiology: Role of deformation imaging
Kowallick, Johannes Tammo; Lotz, Joachim; Hasenfuß, Gerd; Schuster, Andreas
2015-01-01
The left atrium (LA) acts as a modulator of left ventricular (LV) filling. Although there is considerable evidence to support the use of LA maximum and minimum volumes for disease prediction, theoretical considerations and a growing body of literature suggest to focus on the quantification of the three basic LA functions: (1) Reservoir function: collection of pulmonary venous return during LV systole; (2) Conduit function: passage of blood to the left ventricle during early LV diastole; and (3) Contractile booster pump function (augmentation of ventricular filling during late LV diastole. Tremendous advances in our ability to non-invasively characterize all three elements of atrial function include speckle tracking echocardiography (STE), and more recently cardiovascular magnetic resonance myocardial feature tracking (CMR-FT). Corresponding imaging biomarkers are increasingly recognized to have incremental roles in determining prognosis and risk stratification in cardiac dysfunction of different origins. The current editorial introduces the role of STE and CMR-FT for the functional assessment of LA deformation as determined by strain and strain rate imaging and provides an outlook of how this exciting field may develop in the future. PMID:26131333
Speckle tracking echocardiography in patients with septic shock: a case control study (SPECKSS).
Ng, Pauline Yeung; Sin, Wai Ching; Ng, Andrew Kei-Yan; Chan, Wai Ming
2016-05-14
Sepsis-induced myocardial dysfunction is a well-recognized condition and confers worse outcomes in septic patients. Echocardiographic assessment by conventional parameters such as left ventricular ejection fraction (LVEF) is often affected by ongoing changes in preload and afterload conditions. Novel echocardiographic technologies such as speckle tracking echocardiography (STE) have evolved for direct assessment of the myocardial function. We investigate the measurement of myocardial strain by speckle tracking echocardiography for the diagnosis of sepsis-induced myocardial dysfunction. This is a case-control study at a university-affiliated medical intensive care unit. Consecutive adult medical patients admitted with a diagnosis of septic shock were included. Patients with other causes of myocardial dysfunction were excluded. They were compared to age-matched, gender-matched, and cardiovascular risk-factor-matched controls, who were admitted to hospital for sepsis but did not develop septic shock. Transthoracic echocardiography was performed on all patients within 24 hours of diagnosis, and a reassessment echocardiogram was performed in the study group of patients upon recovery. Patients with septic shock (n = 33) (study group) and 29 matched patients with sepsis but no septic shock (control group) were recruited. The mean sequential organ failure assessment (SOFA) score for the study and control groups were 10.2 and 1.6, respectively (P < 0.001). In patients with septic shock, the mean arterial pressure was lower (76 mmHg vs 82 mmHg, P = 0.032), and the heart rate was higher (99 bpm vs 86 bpm, P = 0.008). The cardiac output (5.9 L/min vs 5.5 L/min, P = 0.401) and systemic vascular resistance (1090 dynes•sec/cm(5) vs 1194 dynes•sec/cm(5), P = 0.303) were similar. The study group had a greater degree of myocardial dysfunction measured by global longitudinal strain (GLS) (-14.5 % vs -18.3 %, P <0.001), and the myocardial strain differed upon diagnosis and recovery (-14.5 % vs -16.0 %, P = 0.010). Conventional echocardiographic measurements such as LVEF (59 % in the study group vs 61 % in the control group, P = 0.169) did not differ between the two groups. Speckle tracking echocardiography can detect significant left ventricular impairment in patients with septic shock, which was not otherwise detectable by conventional echocardiography. The reversible nature of myocardial dysfunction in sepsis was also demonstrable. This echocardiographic technique is useful in the diagnosis and monitoring of sepsis-induced myocardial dysfunction.
Jian, Zhongping; Pearce, Jeremy; Mittleman, Daniel M
2003-07-18
We describe observations of the amplitude and phase of an electric field diffusing through a three-dimensional random medium, using terahertz time-domain spectroscopy. These measurements are spatially resolved with a resolution smaller than the speckle spot size and temporally resolved with a resolution better than one optical cycle. By computing correlation functions between fields measured at different positions and with different temporal delays, it is possible to obtain information about individual scattering events experienced by the diffusing field. This represents a new method for characterizing a multiply scattered wave.
[Elastic registration method to compute deformation functions for mitral valve].
Yang, Jinyu; Zhang, Wan; Yin, Ran; Deng, Yuxiao; Wei, Yunfeng; Zeng, Junyi; Wen, Tong; Ding, Lu; Liu, Xiaojian; Li, Yipeng
2014-10-01
Mitral valve disease is one of the most popular heart valve diseases. Precise positioning and displaying of the valve characteristics is necessary for the minimally invasive mitral valve repairing procedures. This paper presents a multi-resolution elastic registration method to compute the deformation functions constructed from cubic B-splines in three dimensional ultrasound images, in which the objective functional to be optimized was generated by maximum likelihood method based on the probabilistic distribution of the ultrasound speckle noise. The algorithm was then applied to register the mitral valve voxels. Numerical results proved the effectiveness of the algorithm.
Symplectic multiparticle tracking model for self-consistent space-charge simulation
Qiang, Ji
2017-01-23
Symplectic tracking is important in accelerator beam dynamics simulation. So far, to the best of our knowledge, there is no self-consistent symplectic space-charge tracking model available in the accelerator community. In this paper, we present a two-dimensional and a three-dimensional symplectic multiparticle spectral model for space-charge tracking simulation. This model includes both the effect from external fields and the effect of self-consistent space-charge fields using a split-operator method. Such a model preserves the phase space structure and shows much less numerical emittance growth than the particle-in-cell model in the illustrative examples.
Symplectic multiparticle tracking model for self-consistent space-charge simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qiang, Ji
Symplectic tracking is important in accelerator beam dynamics simulation. So far, to the best of our knowledge, there is no self-consistent symplectic space-charge tracking model available in the accelerator community. In this paper, we present a two-dimensional and a three-dimensional symplectic multiparticle spectral model for space-charge tracking simulation. This model includes both the effect from external fields and the effect of self-consistent space-charge fields using a split-operator method. Such a model preserves the phase space structure and shows much less numerical emittance growth than the particle-in-cell model in the illustrative examples.
Speckle interferometry of asteroids
NASA Technical Reports Server (NTRS)
Drummond, Jack
1988-01-01
This final report for NASA Contract NAGw-867 consists of abstracts of the first three papers in a series of four appearing in Icarus that were funded by the preceding contract NAGw-224: (1) Speckle Interferometry of Asteroids I. 433 Eros; (2) Speckle Interferometry of Asteroids II. 532 Herculina; (3) Speckle Interferometry of Asteroids III. 511 Davida and its Photometry; and the fourth abstract attributed to NAGw-867, (4) Speckle Interferometry of Asteroids IV. Reconstructed images of 4 Vesta; and a review of the results from the asteroid interferometry program at Steward Observatory prepared for the Asteroids II book, (5) Speckle Interferometry of Asteroids. Two papers on asteroids, indirectly related to speckle interferometry, were written in part under NAGw-867. One is in press and its abstract is included here: Photometric Geodesy of Main-Belt Asteroids. II. Analysis of Lightcurves for Poles, Periods and Shapes; and the other paper, Triaxial Ellipsoid Dimensions and Rotational Pole of 2 Pallas from Two Stellar Occultations, is included in full.
Multiple object, three-dimensional motion tracking using the Xbox Kinect sensor
NASA Astrophysics Data System (ADS)
Rosi, T.; Onorato, P.; Oss, S.
2017-11-01
In this article we discuss the capability of the Xbox Kinect sensor to acquire three-dimensional motion data of multiple objects. Two experiments regarding fundamental features of Newtonian mechanics are performed to test the tracking abilities of our setup. Particular attention is paid to check and visualise the conservation of linear momentum, angular momentum and energy. In both experiments, two objects are tracked while falling in the gravitational field. The obtained data is visualised in a 3D virtual environment to help students understand the physics behind the performed experiments. The proposed experiments were analysed with a group of university students who are aspirant physics and mathematics teachers. Their comments are presented in this paper.
Uddin, Muhammad Shahin; Tahtali, Murat; Lambert, Andrew J; Pickering, Mark R; Marchese, Margaret; Stuart, Iain
2016-05-20
Compared with other medical-imaging modalities, ultrasound (US) imaging is a valuable way to examine the body's internal organs, and two-dimensional (2D) imaging is currently the most common technique used in clinical diagnoses. Conventional 2D US imaging systems are highly flexible cost-effective imaging tools that permit operators to observe and record images of a large variety of thin anatomical sections in real time. Recently, 3D US imaging has also been gaining popularity due to its considerable advantages over 2D US imaging. It reduces dependency on the operator and provides better qualitative and quantitative information for an effective diagnosis. Furthermore, it provides a 3D view, which allows the observation of volume information. The major shortcoming of any type of US imaging is the presence of speckle noise. Hence, speckle reduction is vital in providing a better clinical diagnosis. The key objective of any speckle-reduction algorithm is to attain a speckle-free image while preserving the important anatomical features. In this paper we introduce a nonlinear multi-scale complex wavelet-diffusion based algorithm for speckle reduction and sharp-edge preservation of 2D and 3D US images. In the proposed method we use a Rayleigh and Maxwell-mixture model for 2D and 3D US images, respectively, where a genetic algorithm is used in combination with an expectation maximization method to estimate mixture parameters. Experimental results using both 2D and 3D synthetic, physical phantom, and clinical data demonstrate that our proposed algorithm significantly reduces speckle noise while preserving sharp edges without discernible distortions. The proposed approach performs better than the state-of-the-art approaches in both qualitative and quantitative measures.
Candan, Ozkan; Gecmen, Cetin; Bayam, Emrah; Guner, Ahmet; Celik, Mehmet; Doğan, Cem
2017-06-01
In this study, we investigated whether mechanical dispersion which reflects electrical abnormality and other echocardiographic and clinic parameters predict appropriate ICD shock in patients undergone ICD implantation for hypertrophic cardiomyopathy. Sixty-three patients who received ICD implantation for primary or secondary prevention were included in the study. Patients' clinical, electrocardiographic, 2D classic, and speckle tracking echocardiographic data were collected. Mechanical dispersion was defined as the standard deviation of time to peak negative strain in 18 left ventricular segments. Appropriate ICD therapy was defined as cardioversion or defibrillation due to ventricular tachycardia or fibrillation. Patients were divided into two groups as occurrence or the absence of appropriate ICD therapy. A total of 17 (26.9%) patients were observed to have an appropriate ICD therapy during follow-up periods. In patients who performed appropriate ICD therapy, a larger left atrial volume index, higher sudden cardiac death (SCD)-Risk Score, longer mechanical dispersion, and decreased global longitudinal peak strain (GLPS) were observed. In multivariate logistic regression analysis, including (GLPS, mechanical dispersion, LAVi, and SCD-Risk Score) was used to determine independent predictors of occurrence of appropriate ICD therapy during the follow-up. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be independent predictors of occurrence of appropriate ICD therapy. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be predictive for appropriate ICD therapy in patients receiving ICD implantation. Readily measurable mechanical dispersion and GLPS could be helpful to distinguish patients at high risk who could optimally benefit from ICD therapy. © 2017, Wiley Periodicals, Inc.
Detection of small subendocardial infarction using speckle tracking echocardiography in a rat model.
Bachner-Hinenzon, Noa; Shlomo, Liron; Khamis, Hanan; Ertracht, Offir; Vered, Zvi; Malka, Assaf; Binah, Ofer; Adam, Dan
2016-10-01
It is challenging to detect small nontransmural infarcts visually or automatically. As it is important to detect myocardial infarction (MI) at early stages, we tested the hypothesis that small nontransmural MI can be detected using speckle tracking echocardiography (STE) at the acute stage. Minimal nontransmural infarcts were induced in 18 rats by causing recurrent ischemia-reperfusion of the left anterior descending (LAD) coronary artery, followed by a 30-min ligation and by reperfusion. A week later, the scar size was measured by histological analysis. Each rat underwent three echocardiography measurements: at baseline, 1 day post-MI, and 1 week post-MI. To measure the peak circumferential strain (CS), peak systolic CS, radial strain (RS), and time-to-peak (TTP) of the CS, short-axis view of the apex was analyzed by a STE program. The TTP was normalized by the duration of the heart cycle to create percent change of heart cycle. Histological analysis after 1 week showed scar size of 4±6% at the anterior wall. At 24 h post-MI, the peak CS, peak systolic CS, and RS were reduced compared to baseline at the anterior wall due to the MI, and at the adjacent segments-the anterior septum and lateral wall, due to stunning (P<.05). However, only the anterior wall, the genuine damaged segment, showed prolonged TTP vs baseline (baseline 36%, 24 h 48%, P<.05). The TTP of the CS can distinguish between regions adjacent to MI (stunned or tethered) and MI, even in small nontransmural infarcts. © 2016, Wiley Periodicals, Inc.
AN IMPROVED DISTANCE AND MASS ESTIMATE FOR SGR A* FROM A MULTISTAR ORBIT ANALYSIS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boehle, A.; Ghez, A. M.; Meyer, L.
2016-10-10
We present new, more precise measurements of the mass and distance of our Galaxy’s central supermassive black hole, Sgr A*. These results stem from a new analysis that more than doubles the time baseline for astrometry of faint stars orbiting Sgr A*, combining 2 decades of speckle imaging and adaptive optics data. Specifically, we improve our analysis of the speckle images by using information about a star’s orbit from the deep adaptive optics data (2005–2013) to inform the search for the star in the speckle years (1995–2005). When this new analysis technique is combined with the first complete re-reduction ofmore » Keck Galactic Center speckle images using speckle holography, we are able to track the short-period star S0-38 ( K -band magnitude = 17, orbital period = 19 yr) through the speckle years. We use the kinematic measurements from speckle holography and adaptive optics to estimate the orbits of S0-38 and S0-2 and thereby improve our constraints of the mass ( M {sub bh}) and distance ( R {sub o} ) of Sgr A*: M {sub bh} = (4.02 ± 0.16 ± 0.04) × 10{sup 6} M {sub ⊙} and 7.86 ± 0.14 ± 0.04 kpc. The uncertainties in M {sub bh} and R {sub o} as determined by the combined orbital fit of S0-2 and S0-38 are improved by a factor of 2 and 2.5, respectively, compared to an orbital fit of S0-2 alone and a factor of ∼2.5 compared to previous results from stellar orbits. This analysis also limits the extended dark mass within 0.01 pc to less than 0.13 × 10{sup 6} M {sub ⊙} at 99.7% confidence, a factor of 3 lower compared to prior work.« less
Prediction of venous wound healing with laser speckle imaging.
van Vuuren, Timme Maj; Van Zandvoort, Carina; Doganci, Suat; Zwiers, Ineke; tenCate-Hoek, Arina J; Kurstjens, Ralph Lm; Wittens, Cees Ha
2017-12-01
Introduction Laser speckle imaging is used for noninvasive assessment of blood flow of cutaneous wounds. The aim of this study was to assess if laser speckle imaging can be used as a predictor of venous ulcer healing. Methods After generating the flux speckle images, three regions of interest (ROI) were identified to measure the flow. Sensitivity, specificity, negative predictive value, and positive predictive value for ulcer healing were calculated. Results In total, 17 limbs were included. A sensitivity of 92.3%, specificity of 75.0%, PPV of 80.0%, and NPV 75.0% were found in predicting wound healing based on laser speckle images. Mean flux values were lowest in the center (ROI I) and showed an increase at the wound edge (ROI II, p = 0.03). Conclusion Laser speckle imaging shows acceptable sensitivity and specificity rates in predicting venous ulcer healing. The wound edge proved to be the best probability for the prediction of wound healing.
NASA Astrophysics Data System (ADS)
Petrochenko, Andrey; Konyakhin, Igor
2017-06-01
In connection with the development of robotics have become increasingly popular variety of three-dimensional reconstruction of the system mapping and image-set received from the optical sensors. The main objective of technical and robot vision is the detection, tracking and classification of objects of the space in which these systems and robots operate [15,16,18]. Two-dimensional images sometimes don't contain sufficient information to address those or other problems: the construction of the map of the surrounding area for a route; object identification, tracking their relative position and movement; selection of objects and their attributes to complement the knowledge base. Three-dimensional reconstruction of the surrounding space allows you to obtain information on the relative positions of objects, their shape, surface texture. Systems, providing training on the basis of three-dimensional reconstruction of the results of the comparison can produce two-dimensional images of three-dimensional model that allows for the recognition of volume objects on flat images. The problem of the relative orientation of industrial robots with the ability to build threedimensional scenes of controlled surfaces is becoming actual nowadays.
Toprak, Cuneyt; Kahveci, Gokhan; Kilicgedik, Alev; Pala, Selcuk; Kirma, Cevat; Tabakci, Mehmet Mustafa; Inanir, Mehmet; Esen, Ali Metin
2016-10-01
The goal of this study was to determine changes in left atrial (LA) function with two-dimensional speckle tracking echocardiography (2DSTE) and real-time full-volume three-dimensional echocardiography (RT3DE) after percutaneous mitral valve repair with the MitraClip system. Furthermore, we investigated whether baseline and/or changes in LA function after MitraClip repair had any impact on prognosis. A total of 25 consecutive patients (age: 57±12 years, 76% male) with moderate-to-severe or severe mitral regurgitation (MR) were included. Patients underwent 2DSTE and RT3DE before the clip implantation and after the 12-month follow-up. Prognostic data were also recorded via the use of telephone calls and follow-up visits for 12 months after the procedure. Compared with the baseline, the LA reservoir strain (LA-Res) (7.66±4.3% vs 11.15±7.5%, P<.001) and LA contraction strain (LA-Pump) (4.64±4.3% vs 7.63±5.8%, P=.001) improved significantly after MitraClip repair; significant improvements were also seen in three-dimensional (3D) minimum LA volume index (LAV min) and maximum LA volume index (LAV max). On the other hand, conventional LA indices did not change. In total, eleven major adverse cardiac events (MACE) were observed at the 1-year follow-up. In univariate analyses, the preprocedural echocardiographic parameters that were associated with the MACE within 1 year after MitraClip repair were 3D-LAV min and LA-Res. Furthermore, these indices significantly correlated with improved functional parameters and MR reduction. In conclusion, a successful MitraClip procedure can reverse the process of LA remodeling within 12 months, and this can be detected by 2DSTE and RT3DE. Also, patients with preprocedural lower LA-Res and higher 3D-LAV min had the worst prognoses at the 1-year follow-up. © 2016, Wiley Periodicals, Inc.
Peikon, Ian D; Fitzsimmons, Nathan A; Lebedev, Mikhail A; Nicolelis, Miguel A L
2009-06-15
Collection and analysis of limb kinematic data are essential components of the study of biological motion, including research into biomechanics, kinesiology, neurophysiology and brain-machine interfaces (BMIs). In particular, BMI research requires advanced, real-time systems capable of sampling limb kinematics with minimal contact to the subject's body. To answer this demand, we have developed an automated video tracking system for real-time tracking of multiple body parts in freely behaving primates. The system employs high-contrast markers painted on the animal's joints to continuously track the three-dimensional positions of their limbs during activity. Two-dimensional coordinates captured by each video camera are combined and converted to three-dimensional coordinates using a quadratic fitting algorithm. Real-time operation of the system is accomplished using direct memory access (DMA). The system tracks the markers at a rate of 52 frames per second (fps) in real-time and up to 100fps if video recordings are captured to be later analyzed off-line. The system has been tested in several BMI primate experiments, in which limb position was sampled simultaneously with chronic recordings of the extracellular activity of hundreds of cortical cells. During these recordings, multiple computational models were employed to extract a series of kinematic parameters from neuronal ensemble activity in real-time. The system operated reliably under these experimental conditions and was able to compensate for marker occlusions that occurred during natural movements. We propose that this system could also be extended to applications that include other classes of biological motion.
NASA Technical Reports Server (NTRS)
Opower, Hans (Editor)
1990-01-01
Recent advances in CO2 laser technology and its applications are examined. Topics discussed include the excitation of CO2 lasers by microwave discharge, a compact RF-excited 12-kW CO2 laser, a robotic laser for three-dimensional cutting and welding, three-dimensional CO2-laser material processing with gantry machine systems, and a comparison of hollow metallic waveguides and optical fibers for transmitting CO2-laser radiation. Consideration is given to an aerodynamic window with a pump cavity and a supersonic jet, cutting and welding Al using a high-repetition-rate pulsed CO2 laser, speckle reduction in CO2 heterodyne laser radar systems, high-power-laser float-zone crystal growth, melt dynamics in surface processing with laser radiation, laser hardfacing, surface melting of AlSi10Mg with CO2 laser radiation, material processing with Cu-vapor lasers, light-induced flow at a metal surface, and absorption measurements in high-power CW CO2-laser processing of materials.
NASA Technical Reports Server (NTRS)
Lourenco, L. M. M.; Krothapalli, A.
1987-01-01
One of the difficult problems in experimental fluid dynamics remains the determination of the vorticity field in fluid flows. Recently, a novel velocity measurement technique, commonly known as Laser Speckle or Particle Image Displacement Velocimetry became available. This technique permits the simultaneous visualization of the 2 dimensional streamline pattern in unsteady flows and the quantification of the velocity field. The main advantage of this new technique is that the whole 2 dimensional velocity field can be recorded with great accuracy and spatial resolution, from which the instantaneous vorticity field can be easily obtained. A apparatus used for taking particle displacement images is described. Local coherent illumination by the probe laser beam yielded Young's fringes of good quality at almost every location of the flow field. These fringes were analyzed and the velocity and vorticity fields were derived. Several conclusions drawn are discussed.
Towards Automated Three-Dimensional Tracking of Nephrons through Stacked Histological Image Sets
Bhikha, Charita; Andreasen, Arne; Christensen, Erik I.; Letts, Robyn F. R.; Pantanowitz, Adam; Rubin, David M.; Thomsen, Jesper S.; Zhai, Xiao-Yue
2015-01-01
An automated approach for tracking individual nephrons through three-dimensional histological image sets of mouse and rat kidneys is presented. In a previous study, the available images were tracked manually through the image sets in order to explore renal microarchitecture. The purpose of the current research is to reduce the time and effort required to manually trace nephrons by creating an automated, intelligent system as a standard tool for such datasets. The algorithm is robust enough to isolate closely packed nephrons and track their convoluted paths despite a number of nonideal, interfering conditions such as local image distortions, artefacts, and interstitial tissue interference. The system comprises image preprocessing, feature extraction, and a custom graph-based tracking algorithm, which is validated by a rule base and a machine learning algorithm. A study of a selection of automatically tracked nephrons, when compared with manual tracking, yields a 95% tracking accuracy for structures in the cortex, while those in the medulla have lower accuracy due to narrower diameter and higher density. Limited manual intervention is introduced to improve tracking, enabling full nephron paths to be obtained with an average of 17 manual corrections per mouse nephron and 58 manual corrections per rat nephron. PMID:26170896
Towards Automated Three-Dimensional Tracking of Nephrons through Stacked Histological Image Sets.
Bhikha, Charita; Andreasen, Arne; Christensen, Erik I; Letts, Robyn F R; Pantanowitz, Adam; Rubin, David M; Thomsen, Jesper S; Zhai, Xiao-Yue
2015-01-01
An automated approach for tracking individual nephrons through three-dimensional histological image sets of mouse and rat kidneys is presented. In a previous study, the available images were tracked manually through the image sets in order to explore renal microarchitecture. The purpose of the current research is to reduce the time and effort required to manually trace nephrons by creating an automated, intelligent system as a standard tool for such datasets. The algorithm is robust enough to isolate closely packed nephrons and track their convoluted paths despite a number of nonideal, interfering conditions such as local image distortions, artefacts, and interstitial tissue interference. The system comprises image preprocessing, feature extraction, and a custom graph-based tracking algorithm, which is validated by a rule base and a machine learning algorithm. A study of a selection of automatically tracked nephrons, when compared with manual tracking, yields a 95% tracking accuracy for structures in the cortex, while those in the medulla have lower accuracy due to narrower diameter and higher density. Limited manual intervention is introduced to improve tracking, enabling full nephron paths to be obtained with an average of 17 manual corrections per mouse nephron and 58 manual corrections per rat nephron.
NASA Astrophysics Data System (ADS)
Darwiesh, M.; El-Sherif, Ashraf F.; El-Ghandour, Hatem; Aly, Hussein A.; Mokhtar, A. M.
2011-03-01
Optical imaging systems are widely used in different applications include tracking for portable scanners; input pointing devices for laptop computers, cell phones, and cameras, fingerprint-identification scanners, optical navigation for target tracking, and in optical computer mouse. We presented an experimental work to measure and analyze the laser speckle pattern (LSP) produced from different optical sources (i.e. various color LEDs, 3 mW diode laser, and 10mW He-Ne laser) with different produced operating surfaces (Gabor hologram diffusers), and how they affects the performance of the optical imaging systems; speckle size and signal-to-noise ratio (signal is represented by the patches of the speckles that contain or carry information, and noise is represented by the whole remaining part of the selected image). The theoretical and experimental studies of the colorimetry (color correction is done in the color images captured by the optical imaging system to produce realistic color images which contains most of the information in the image by selecting suitable gray scale which contains most of the informative data in the image, this is done by calculating the accurate Red-Green-Blue (RGB) color components making use of the measured spectrum for light sources, and color matching functions of International Telecommunication Organization (ITU-R709) for CRT phosphorus, Tirinton-SONY Model ) for the used optical sources are investigated and introduced to present the relations between the signal-to-noise ratios with different diffusers for each light source. The source surface coupling has been discussed and concludes that the performance of the optical imaging system for certain source varies from worst to best based on the operating surface. The sensor /surface coupling has been studied and discussed for the case of He-Ne laser and concludes the speckle size is ranged from 4.59 to 4.62 μm, which are slightly different or approximately the same for all produced diffusers (which satisfies the fact that the speckle size is independent on the illuminating surface). But, the calculated value of signal-tonoise ratio takes different values ranged from 0.71 to 0.92 for different diffuser. This means that the surface texture affects the performance of the optical sensor because, all images captured for all diffusers under the same conditions [same source (He-Ne laser), same distances of the experimental set-up, and the same sensor (CCD camera)].
Measurement of absolute regional lung air volumes from near-field x-ray speckles.
Leong, Andrew F T; Paganin, David M; Hooper, Stuart B; Siew, Melissa L; Kitchen, Marcus J
2013-11-18
Propagation-based phase contrast x-ray (PBX) imaging yields high contrast images of the lung where airways that overlap in projection coherently scatter the x-rays, giving rise to a speckled intensity due to interference effects. Our previous works have shown that total and regional changes in lung air volumes can be accurately measured from two-dimensional (2D) absorption or phase contrast images when the subject is immersed in a water-filled container. In this paper we demonstrate how the phase contrast speckle patterns can be used to directly measure absolute regional lung air volumes from 2D PBX images without the need for a water-filled container. We justify this technique analytically and via simulation using the transport-of-intensity equation and calibrate the technique using our existing methods for measuring lung air volume. Finally, we show the full capabilities of this technique for measuring regional differences in lung aeration.
Lei, Yi; Li, Jianqiang; Wu, Rui; Fan, Yuting; Fu, Songnian; Yin, Feifei; Dai, Yitang; Xu, Kun
2017-06-01
Based on the observed random fluctuation phenomenon of speckle pattern across multimode fiber (MMF) facet and received optical power distribution across three output ports, we experimentally investigate the statistic characteristics of a 3×3 radio frequency multiple-input multiple-output (MIMO) channel enabled by mode division multiplexing in a conventional 50 µm MMF using non-mode-selective three-dimensional waveguide photonic lanterns as mode multiplexer and demultiplexer. The impacts of mode coupling on the MIMO channel coefficients, channel matrix, and channel capacity have been analyzed over different fiber lengths. The results indicate that spatial multiplexing benefits from the greater fiber length with stronger mode coupling, despite a higher optical loss.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Masson-Laborde, P. E.; Depierreux, S.; Loiseau, P.
2014-03-15
The origin of the low level of stimulated Brillouin scattering (SBS) observed in laser-plasma experiments carried out with a single laser speckle is investigated by means of three-dimensional simulations and modeling in the limit when the laser beam power P is well above the critical power for ponderomotive self-focusing We find that the order of magnitude of the time averaged reflectivities, together with the temporal and spatial SBS localization observed in our simulations, are correctly reproduced by our modeling. It is observed that, after a short transient stage, SBS reaches a significant level only (i) as long as the incidentmore » laser pulse is increasing in amplitude and (ii) in a single self-focused speckle located in the low-density front part of the plasma. In order to describe self-focusing in an inhomogeneous expanding plasma, we have derived a new Lagrangian density describing this process. Using then a variational approach, our model reproduces the position and the peak intensity of the self-focusing hot spot in the front part of the plasma density profile as well as the local density depletion in this hot spot. The knowledge of these parameters then makes it possible to estimate the spatial amplification of SBS as a function of the laser beam power and consequently to explain the experimentally observed SBS reflectivity, considerably reduced with respect to standard theory in the regime of large laser beam power.« less
Trillo, C; Doval, A F; López-Vázquez, J C
2010-07-05
Phase evaluation methods based on the 2D spatial Fourier transform of a speckle interferogram with spatial carrier usually assume that the Fourier spectrum of the interferogram has a trimodal distribution, i. e. that the side lobes corresponding to the interferential terms do not overlap the other two spectral terms, which are related to the intensity of the object and reference beams, respectively. Otherwise, part of the spectrum of the object beam is inside the inverse-transform window of the selected interference lobe and induces an error in the resultant phase map. We present a technique for the acquisition and processing of speckle interferogram sequences that separates the interference lobes from the other spectral terms when the aforementioned assumption does not apply and regardless of the temporal bandwidth of the phase signal. It requires the recording of a sequence of interferograms with spatial and temporal carriers, and their processing with a 3D Fourier transform. In the resultant 3D spectrum, the spatial and temporal carriers separate the conjugate interferential terms from each other and from the term related to the object beam. Experimental corroboration is provided through the measurement of the amplitude of surface acoustic waves in plates with a double-pulsed TV holography setup. The results obtained with the proposed method are compared to those obtained with the processing of individual interferograms with the regular spatial-carrier 2D Fourier transform method.
Levy, Philip T; Machefsky, Aliza; Sanchez, Aura A; Patel, Meghna D; Rogal, Sarah; Fowler, Susan; Yaeger, Lauren; Hardi, Angela; Holland, Mark R; Hamvas, Aaron; Singh, Gautam K
2016-03-01
Establishment of the range of reference values and associated variations of two-dimensional speckle-tracking echocardiography (2DSTE)-derived left ventricular (LV) strain is a prerequisite for its routine clinical adoption in pediatrics. The aims of this study were to perform a meta-analysis of normal ranges of LV global longitudinal strain (GLS), global circumferential strain (GCS), and global radial strain (GRS) measurements derived by 2DSTE in children and to identify confounding factors that may contribute to variance in reported measures. A systematic review was launched in MEDLINE, Embase, Scopus, the Cumulative Index to Nursing and Allied Health Literature, and the Cochrane Library. Search hedges were created to cover the concepts of pediatrics, STE, and left-heart ventricle. Two investigators independently identified and included studies if they reported 2DSTE-derived LV GLS, GCS, or GRS. The weighted mean was estimated by using random effects models with 95% CIs, heterogeneity was assessed using the Cochran Q statistic and the inconsistency index (I(2)), and publication bias was evaluated using the Egger test. Effects of demographic (age), clinical, and vendor variables were assessed in a metaregression. The search identified 2,325 children from 43 data sets. The reported normal mean values of GLS among the studies varied from -16.7% to -23.6% (mean, -20.2%; 95% CI, -19.5% to -20.8%), GCS varied from -12.9% to -31.4% (mean, -22.3%; 95% CI, -19.9% to -24.6%), and GRS varied from 33.9% to 54.5% (mean, 45.2%; 95% CI, 38.3% to 51.7%). Twenty-six studies reported longitudinal strain only from the apical four-chamber view, with a mean of -20.4% (95% CI, -19.8% to -21.7%). Twenty-three studies reported circumferential strain (mean, -20.3%; 95% CI, -19.4% to -21.2%) and radial strain (mean, 46.7%; 95% CI, 42.3% to 51.1%) from the short-axis view at the midventricular level. A significant apex-to-base segmental longitudinal strain gradient (P < .01) was observed in the LV free wall. There was significant between-study heterogeneity and inconsistency (I(2) > 94% and P < .001 for each strain measure), which was not explained by age, gender, body surface area, blood pressure, heart rate, frame rate, frame rate/heart rate ratio, tissue-tracking methodology, location of reported strain value along the strain curve, ultrasound equipment, or software. The metaregression showed that these effects were not significant determinants of variations among normal ranges of strain values. There was no evidence of publication bias (P = .40). This study defines reference values of 2DSTE-derived LV strain in children on the basis of a meta-analysis. In healthy children, mean LV GLS was -20.2% (95% CI, -19.5% to -20.8%), mean GCS was -22.3% (95% CI, -19.9% to -24.6%), and mean GRS was 45.2% (95% CI, 38.3% to 51.7%). LV segmental longitudinal strain has a stable apex-to-base gradient that is preserved throughout maturation. Although variations among different reference ranges in this meta-analysis were not dependent on differences in demographic, clinical, or vendor parameters, age- and vendor-specific referenced ranges were established as well. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
A Novel Method for Tracking Individuals of Fruit Fly Swarms Flying in a Laboratory Flight Arena
Cheng, Xi En; Qian, Zhi-Ming; Wang, Shuo Hong; Jiang, Nan; Guo, Aike; Chen, Yan Qiu
2015-01-01
The growing interest in studying social behaviours of swarming fruit flies, Drosophila melanogaster, has heightened the need for developing tools that provide quantitative motion data. To achieve such a goal, multi-camera three-dimensional tracking technology is the key experimental gateway. We have developed a novel tracking system for tracking hundreds of fruit flies flying in a confined cubic flight arena. In addition to the proposed tracking algorithm, this work offers additional contributions in three aspects: body detection, orientation estimation, and data validation. To demonstrate the opportunities that the proposed system offers for generating high-throughput quantitative motion data, we conducted experiments on five experimental configurations. We also performed quantitative analysis on the kinematics and the spatial structure and the motion patterns of fruit fly swarms. We found that there exists an asymptotic distance between fruit flies in swarms as the population density increases. Further, we discovered the evidence for repulsive response when the distance between fruit flies approached the asymptotic distance. Overall, the proposed tracking system presents a powerful method for studying flight behaviours of fruit flies in a three-dimensional environment. PMID:26083385
Xu, Jing; Wong, Kevin; Jian, Yifan; Sarunic, Marinko V
2014-02-01
In this report, we describe a graphics processing unit (GPU)-accelerated processing platform for real-time acquisition and display of flow contrast images with Fourier domain optical coherence tomography (FDOCT) in mouse and human eyes in vivo. Motion contrast from blood flow is processed using the speckle variance OCT (svOCT) technique, which relies on the acquisition of multiple B-scan frames at the same location and tracking the change of the speckle pattern. Real-time mouse and human retinal imaging using two different custom-built OCT systems with processing and display performed on GPU are presented with an in-depth analysis of performance metrics. The display output included structural OCT data, en face projections of the intensity data, and the svOCT en face projections of retinal microvasculature; these results compare projections with and without speckle variance in the different retinal layers to reveal significant contrast improvements. As a demonstration, videos of real-time svOCT for in vivo human and mouse retinal imaging are included in our results. The capability of performing real-time svOCT imaging of the retinal vasculature may be a useful tool in a clinical environment for monitoring disease-related pathological changes in the microcirculation such as diabetic retinopathy.
Crawford, D C; Bell, D S; Bamber, J C
1993-01-01
A systematic method to compensate for nonlinear amplification of individual ultrasound B-scanners has been investigated in order to optimise performance of an adaptive speckle reduction (ASR) filter for a wide range of clinical ultrasonic imaging equipment. Three potential methods have been investigated: (1) a method involving an appropriate selection of the speckle recognition feature was successful when the scanner signal processing executes simple logarithmic compressions; (2) an inverse transform (decompression) of the B-mode image was effective in correcting for the measured characteristics of image data compression when the algorithm was implemented in full floating point arithmetic; (3) characterising the behaviour of the statistical speckle recognition feature under conditions of speckle noise was found to be the method of choice for implementation of the adaptive speckle reduction algorithm in limited precision integer arithmetic. In this example, the statistical features of variance and mean were investigated. The third method may be implemented on commercially available fast image processing hardware and is also better suited for transfer into dedicated hardware to facilitate real-time adaptive speckle reduction. A systematic method is described for obtaining ASR calibration data from B-mode images of a speckle producing phantom.
Reconstructing the flight kinematics of swarming and mating behavior in wild mosquitoes
USDA-ARS?s Scientific Manuscript database
We describe a tracking system for reconstructing three-dimensional tracks of individual mosquitoes in wild swarms and present the results of validating the system by filming swarms and mating events of the malaria mosquito Anopheles gambiae in Mali. The tracking system is designed to address noisy, ...
Zhang, Zhijun; Zhu, Meihua; Ashraf, Muhammad; Broberg, Craig S; Sahn, David J; Song, Xubo
2014-12-01
Quantitative analysis of right ventricle (RV) motion is important for study of the mechanism of congenital and acquired diseases. Unlike left ventricle (LV), motion estimation of RV is more difficult because of its complex shape and thin myocardium. Although attempts of finite element models on MR images and speckle tracking on echocardiography have shown promising results on RV strain analysis, these methods can be improved since the temporal smoothness of the motion is not considered. The authors have proposed a temporally diffeomorphic motion estimation method in which a spatiotemporal transformation is estimated by optimization of a registration energy functional of the velocity field in their earlier work. The proposed motion estimation method is a fully automatic process for general image sequences. The authors apply the method by combining with a semiautomatic myocardium segmentation method to the RV strain analysis of three-dimensional (3D) echocardiographic sequences of five open-chest pigs under different steady states. The authors compare the peak two-point strains derived by their method with those estimated from the sonomicrometry, the results show that they have high correlation. The motion of the right ventricular free wall is studied by using segmental strains. The baseline sequence results show that the segmental strains in their methods are consistent with results obtained by other image modalities such as MRI. The image sequences of pacing steady states show that segments with the largest strain variation coincide with the pacing sites. The high correlation of the peak two-point strains of their method and sonomicrometry under different steady states demonstrates that their RV motion estimation has high accuracy. The closeness of the segmental strain of their method to those from MRI shows the feasibility of their method in the study of RV function by using 3D echocardiography. The strain analysis of the pacing steady states shows the potential utility of their method in study on RV diseases.
Spinelli, Letizia; Morisco, Carmine; Assante di Panzillo, Emiliano; Izzo, Raffaele; Trimarco, Bruno
2013-04-01
Reverse left ventricular (LV) remodeling (>10 % reduction in LV end-systolic volume) may occur in patients recovering for acute ST-elevation myocardial infarction (STEMI), undergoing percutaneous revascularization of infarct-related coronary artery (PCI). To detect whether LV global torsion obtained by two-dimensional speckle-tracking echocardiography was predictive of reverse LV remodeling, 75 patients with first anterior wall STEMI were studied before (T1) and after PCI (T2) and at 6-month follow-up. Two-year clinical follow-up was also accomplished. LV volumes and both LV sphericity index and conic index were obtained by three-dimensional echocardiography. Reverse remodeling was observed in 25 patients (33 %). By multivariate analysis, independent predictors of reverse LV remodeling were: LV conic index, T2 LV torsion and Δ torsion (difference between T2 and T1 LV torsion expressed as percentage of this latter). According to receiver operating characteristic analysis, 1.34°/cm for T2 LV torsion (sensitivity 88 % and specificity 80 %) and 54 % for Δ torsion (sensitivity 92 % and specificity 82 %) were the optimal cutoff values in predicting reverse LV remodeling. In up to 24 month follow-up, 4 non-fatal re-infarction, 7 hospitalization for heart failure and 4 cardiac deaths occurred. By multivariate Cox analysis, the best variable significantly associated with event-free survival rate was reverse LV remodeling with a hazard ratio = 9.9 (95 % confidence interval, 7.9-31.4, p < 0.01). In conclusion, reverse LV remodeling occurring after anterior wall STEMI is associated with favorable long-term outcome. The improvement of global LV torsion following coronary artery revascularization is the major predictor of reverse LV remodeling.
Polychromatic wave-optics models for image-plane speckle. 2. Unresolved objects.
Van Zandt, Noah R; Spencer, Mark F; Steinbock, Michael J; Anderson, Brian M; Hyde, Milo W; Fiorino, Steven T
2018-05-20
Polychromatic laser light can reduce speckle noise in many wavefront-sensing and imaging applications. To help quantify the achievable reduction in speckle noise, this study investigates the accuracy of three polychromatic wave-optics models under the specific conditions of an unresolved object. Because existing theory assumes a well-resolved object, laboratory experiments are used to evaluate model accuracy. The three models use Monte-Carlo averaging, depth slicing, and spectral slicing, respectively, to simulate the laser-object interaction. The experiments involve spoiling the temporal coherence of laser light via a fiber-based, electro-optic modulator. After the light scatters off of the rough object, speckle statistics are measured. The Monte-Carlo method is found to be highly inaccurate, while depth-slicing error peaks at 7.8% but is generally much lower in comparison. The spectral-slicing method is the most accurate, always producing results within the error bounds of the experiment.
Zhong, Chunyan; Guo, Yanli; Huang, Haiyun; Tan, Liwen; Wu, Yi; Wang, Wenting
2013-01-01
Objectives. To establish 3D models of coronary arteries (CA) and study their application in localization of CA segments identified by Transthoracic Echocardiography (TTE). Methods. Sectional images of the heart collected from the first CVH dataset and contrast CT data were used to establish 3D models of the CA. Virtual dissection was performed on the 3D models to simulate the conventional sections of TTE. Then, we used 2D ultrasound, speckle tracking imaging (STI), and 2D ultrasound plus 3D CA models to diagnose 170 patients and compare the results to coronary angiography (CAG). Results. 3D models of CA distinctly displayed both 3D structure and 2D sections of CA. This simulated TTE imaging in any plane and showed the CA segments that corresponded to 17 myocardial segments identified by TTE. The localization accuracy showed a significant difference between 2D ultrasound and 2D ultrasound plus 3D CA model in the severe stenosis group (P < 0.05) and in the mild-to-moderate stenosis group (P < 0.05). Conclusions. These innovative modeling techniques help clinicians identify the CA segments that correspond to myocardial segments typically shown in TTE sectional images, thereby increasing the accuracy of the TTE-based diagnosis of CHD. PMID:24348745
Decreased Left Ventricular Torsion and Untwisting in Children with Dilated Cardiomyopathy
Jin, Seon Mi; Bae, Eun Jung; Choi, Jung Yun; Yun, Yong Soo
2007-01-01
The purpose of this study was to analyze left ventricular (LV) torsion and untwisting, and to evaluate the correlation between torsion and other components of LV contraction in children with dilated cardiomyopathy (DCM). Segmental and global rotation, rotational rate (Vrot) were measured at three levels of LV using the two-dimensional (2D) speckle tracking imaging (STI) method in 10 DCM patients (range 0.6-15 yr, median 6.5 yr, 3 females) and 17 age- and sex-matched normal controls. Global torsion was decreased in DCM (peak global torsion; 10.9±4.6° vs. 0.3±2.1°, p<0.001). Loss of LV torsion occurred mainly by the diminution of counterclockwise apical rotation and was augmented by somewhat less reduction in clockwise basal rotation. In DCM, the normal counterclockwise apical rotation was not observed, and the apical rotation about the central axis was clockwise or slightly counterclockwise (peak apical rotation; 5.9±4.1° vs. -0.9±3.1°, p<0.001). Systolic counterclockwise Vrot and early diastolic clockwise Vrot at the apical level were decreased or abolished. In DCM, decreased systolic torsion and loss of early diastolic recoil contribute to LV systolic and diastolic dysfunction. The STI method may facilitate the serial evaluation of the LV torsional behavior in clinical settings and give new biomechanical concepts for better management of patients with DCM. PMID:17728501
Kang, Jinbum; Lee, Jae Young; Yoo, Yangmo
2016-06-01
Effective speckle reduction in ultrasound B-mode imaging is important for enhancing the image quality and improving the accuracy in image analysis and interpretation. In this paper, a new feature-enhanced speckle reduction (FESR) method based on multiscale analysis and feature enhancement filtering is proposed for ultrasound B-mode imaging. In FESR, clinical features (e.g., boundaries and borders of lesions) are selectively emphasized by edge, coherence, and contrast enhancement filtering from fine to coarse scales while simultaneously suppressing speckle development via robust diffusion filtering. In the simulation study, the proposed FESR method showed statistically significant improvements in edge preservation, mean structure similarity, speckle signal-to-noise ratio, and contrast-to-noise ratio (CNR) compared with other speckle reduction methods, e.g., oriented speckle reducing anisotropic diffusion (OSRAD), nonlinear multiscale wavelet diffusion (NMWD), the Laplacian pyramid-based nonlinear diffusion and shock filter (LPNDSF), and the Bayesian nonlocal means filter (OBNLM). Similarly, the FESR method outperformed the OSRAD, NMWD, LPNDSF, and OBNLM methods in terms of CNR, i.e., 10.70 ± 0.06 versus 9.00 ± 0.06, 9.78 ± 0.06, 8.67 ± 0.04, and 9.22 ± 0.06 in the phantom study, respectively. Reconstructed B-mode images that were developed using the five speckle reduction methods were reviewed by three radiologists for evaluation based on each radiologist's diagnostic preferences. All three radiologists showed a significant preference for the abdominal liver images obtained using the FESR methods in terms of conspicuity, margin sharpness, artificiality, and contrast, p<0.0001. For the kidney and thyroid images, the FESR method showed similar improvement over other methods. However, the FESR method did not show statistically significant improvement compared with the OBNLM method in margin sharpness for the kidney and thyroid images. These results demonstrate that the proposed FESR method can improve the image quality of ultrasound B-mode imaging by enhancing the visualization of lesion features while effectively suppressing speckle noise.
Speckle: tool for diagnosis assistance
NASA Astrophysics Data System (ADS)
Carvalho, O.; Guyot, S.; Roy, L.; Benderitter, M.; Clairac, B.
2006-09-01
In this paper, we present a new approach of the speckle phenomenon. This method is based on the fractal Brownian motion theory and allows the extraction of three stochastic parameters to characterize the speckle pattern. For the first time, we present the results of this method applied to the discrimination of the healthy vs. pathologic skin. We also demonstrate, in case of the scleroderma, than this method is more accurate than the classical frequential approach.
Quantification of collagen contraction in three-dimensional cell culture.
Kopanska, Katarzyna S; Bussonnier, Matthias; Geraldo, Sara; Simon, Anthony; Vignjevic, Danijela; Betz, Timo
2015-01-01
Many different cell types including fibroblasts, smooth muscle cells, endothelial cells, and cancer cells exert traction forces on the fibrous components of the extracellular matrix. This can be observed as matrix contraction both macro- and microscopically in three-dimensional (3D) tissues models such as collagen type I gels. The quantification of local contraction at the micron scale, including its directionality and speed, in correlation with other parameters such as cell invasion, local protein or gene expression, can provide useful information to study wound healing, organism development, and cancer metastasis. In this article, we present a set of tools to quantify the flow dynamics of collagen contraction, induced by cells migrating out of a multicellular cancer spheroid into a three-dimensional (3D) collagen matrix. We adapted a pseudo-speckle technique that can be applied to bright-field and fluorescent microscopy time series. The image analysis presented here is based on an in-house written software developed in the Matlab (Mathworks) programming environment. The analysis program is freely available from GitHub following the link: http://dx.doi.org/10.5281/zenodo.10116. This tool provides an automatized technique to measure collagen contraction that can be utilized in different 3D cellular systems. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Haichong K.; Fang, Ting Yun; Finocchi, Rodolfo; Boctor, Emad M.
2017-03-01
Three dimensional (3D) ultrasound imaging is becoming a standard mode for medical ultrasound diagnoses. Conventional 3D ultrasound imaging is mostly scanned either by using a two dimensional matrix array or by motorizing a one dimensional array in the elevation direction. However, the former system is not widely assessable due to its cost, and the latter one has limited resolution and field-of-view in the elevation axis. Here, we propose a 3D ultrasound imaging system based on the synthetic tracked aperture approach, in which a robotic arm is used to provide accurate tracking and motion. While the ultrasound probe is moved by a robotic arm, each probe position is tracked and can be used to reconstruct a wider field-of-view as there are no physical barriers that restrict the elevational scanning. At the same time, synthetic aperture beamforming provides a better resolution in the elevation axis. To synthesize the elevational information, the single focal point is regarded as the virtual element, and forward and backward delay-andsum are applied to the radio-frequency (RF) data collected through the volume. The concept is experimentally validated using a general ultrasound phantom, and the elevational resolution improvement of 2.54 and 2.13 times was measured at the target depths of 20 mm and 110 mm, respectively.
UWB Tracking System Design with TDOA Algorithm
NASA Technical Reports Server (NTRS)
Ni, Jianjun; Arndt, Dickey; Ngo, Phong; Phan, Chau; Gross, Julia; Dusl, John; Schwing, Alan
2006-01-01
This presentation discusses an ultra-wideband (UWB) tracking system design effort using a tracking algorithm TDOA (Time Difference of Arrival). UWB technology is exploited to implement the tracking system due to its properties, such as high data rate, fine time resolution, and low power spectral density. A system design using commercially available UWB products is proposed. A two-stage weighted least square method is chosen to solve the TDOA non-linear equations. Matlab simulations in both two-dimensional space and three-dimensional space show that the tracking algorithm can achieve fine tracking resolution with low noise TDOA data. The error analysis reveals various ways to improve the tracking resolution. Lab experiments demonstrate the UWBTDOA tracking capability with fine resolution. This research effort is motivated by a prototype development project Mini-AERCam (Autonomous Extra-vehicular Robotic Camera), a free-flying video camera system under development at NASA Johnson Space Center for aid in surveillance around the International Space Station (ISS).
Propofol Induction's Effect on Cardiac Function
2015-03-31
This Study Was Focused to Evaluate Feasibility of Doppler Tissue Monitoring During the Induction Anesthesia,; and Evaluate Routine Propofol Induction's Effect on Myocardial Tissue Motion, Using Non-invasive Doppler Tissue and 2D Speckle Tracking Imaging.; This is the First Study, to Our Knowledge, Which Has Evaluated the Possible Impact of Propofol Induction on LV Function.
3D motion and strain estimation of the heart: initial clinical findings
NASA Astrophysics Data System (ADS)
Barbosa, Daniel; Hristova, Krassimira; Loeckx, Dirk; Rademakers, Frank; Claus, Piet; D'hooge, Jan
2010-03-01
The quantitative assessment of regional myocardial function remains an important goal in clinical cardiology. As such, tissue Doppler imaging and speckle tracking based methods have been introduced to estimate local myocardial strain. Recently, volumetric ultrasound has become more readily available, allowing therefore the 3D estimation of motion and myocardial deformation. Our lab has previously presented a method based on spatio-temporal elastic registration of ultrasound volumes to estimate myocardial motion and deformation in 3D, overcoming the spatial limitations of the existing methods. This method was optimized on simulated data sets in previous work and is currently tested in a clinical setting. In this manuscript, 10 healthy volunteers, 10 patient with myocardial infarction and 10 patients with arterial hypertension were included. The cardiac strain values extracted with the proposed method were compared with the ones estimated with 1D tissue Doppler imaging and 2D speckle tracking in all patient groups. Although the absolute values of the 3D strain components assessed by this new methodology were not identical to the reference methods, the relationship between the different patient groups was similar.
Real-time visual tracking of less textured three-dimensional objects on mobile platforms
NASA Astrophysics Data System (ADS)
Seo, Byung-Kuk; Park, Jungsik; Park, Hanhoon; Park, Jong-Il
2012-12-01
Natural feature-based approaches are still challenging for mobile applications (e.g., mobile augmented reality), because they are feasible only in limited environments such as highly textured and planar scenes/objects, and they need powerful mobile hardware for fast and reliable tracking. In many cases where conventional approaches are not effective, three-dimensional (3-D) knowledge of target scenes would be beneficial. We present a well-established framework for real-time visual tracking of less textured 3-D objects on mobile platforms. Our framework is based on model-based tracking that efficiently exploits partially known 3-D scene knowledge such as object models and a background's distinctive geometric or photometric knowledge. Moreover, we elaborate on implementation in order to make it suitable for real-time vision processing on mobile hardware. The performance of the framework is tested and evaluated on recent commercially available smartphones, and its feasibility is shown by real-time demonstrations.
Real time markerless motion tracking using linked kinematic chains
Luck, Jason P [Arvada, CO; Small, Daniel E [Albuquerque, NM
2007-08-14
A markerless method is described for tracking the motion of subjects in a three dimensional environment using a model based on linked kinematic chains. The invention is suitable for tracking robotic, animal or human subjects in real-time using a single computer with inexpensive video equipment, and does not require the use of markers or specialized clothing. A simple model of rigid linked segments is constructed of the subject and tracked using three dimensional volumetric data collected by a multiple camera video imaging system. A physics based method is then used to compute forces to align the model with subsequent volumetric data sets in real-time. The method is able to handle occlusion of segments and accommodates joint limits, velocity constraints, and collision constraints and provides for error recovery. The method further provides for elimination of singularities in Jacobian based calculations, which has been problematic in alternative methods.
Multi-camera real-time three-dimensional tracking of multiple flying animals
Straw, Andrew D.; Branson, Kristin; Neumann, Titus R.; Dickinson, Michael H.
2011-01-01
Automated tracking of animal movement allows analyses that would not otherwise be possible by providing great quantities of data. The additional capability of tracking in real time—with minimal latency—opens up the experimental possibility of manipulating sensory feedback, thus allowing detailed explorations of the neural basis for control of behaviour. Here, we describe a system capable of tracking the three-dimensional position and body orientation of animals such as flies and birds. The system operates with less than 40 ms latency and can track multiple animals simultaneously. To achieve these results, a multi-target tracking algorithm was developed based on the extended Kalman filter and the nearest neighbour standard filter data association algorithm. In one implementation, an 11-camera system is capable of tracking three flies simultaneously at 60 frames per second using a gigabit network of nine standard Intel Pentium 4 and Core 2 Duo computers. This manuscript presents the rationale and details of the algorithms employed and shows three implementations of the system. An experiment was performed using the tracking system to measure the effect of visual contrast on the flight speed of Drosophila melanogaster. At low contrasts, speed is more variable and faster on average than at high contrasts. Thus, the system is already a useful tool to study the neurobiology and behaviour of freely flying animals. If combined with other techniques, such as ‘virtual reality’-type computer graphics or genetic manipulation, the tracking system would offer a powerful new way to investigate the biology of flying animals. PMID:20630879
Jiang, Chao; Zhang, Hongyan; Wang, Jia; Wang, Yaru; He, Heng; Liu, Rui; Zhou, Fangyuan; Deng, Jialiang; Li, Pengcheng; Luo, Qingming
2011-11-01
Laser speckle imaging (LSI) is a noninvasive and full-field optical imaging technique which produces two-dimensional blood flow maps of tissues from the raw laser speckle images captured by a CCD camera without scanning. We present a hardware-friendly algorithm for the real-time processing of laser speckle imaging. The algorithm is developed and optimized specifically for LSI processing in the field programmable gate array (FPGA). Based on this algorithm, we designed a dedicated hardware processor for real-time LSI in FPGA. The pipeline processing scheme and parallel computing architecture are introduced into the design of this LSI hardware processor. When the LSI hardware processor is implemented in the FPGA running at the maximum frequency of 130 MHz, up to 85 raw images with the resolution of 640×480 pixels can be processed per second. Meanwhile, we also present a system on chip (SOC) solution for LSI processing by integrating the CCD controller, memory controller, LSI hardware processor, and LCD display controller into a single FPGA chip. This SOC solution also can be used to produce an application specific integrated circuit for LSI processing.
Laser backlight unit based on a leaky optical fiber
NASA Astrophysics Data System (ADS)
Okuda, Yuuto; Onoda, Kousuke; Fujieda, Ichiro
2012-07-01
A backlight unit is constructed by laying out an optical fiber on a two-dimensional plane and letting the light leak out in a controlled manner. In experiment, we formed multiple grooves on the surface of a plastic optical fiber by pressing a heated knife edge. The depth of the groove determined the percentage of the optical power leaking out. The optical fiber with multiple grooves was embedded in an acrylic plate with a spiral trench, and a diffuser sheet was placed over it. When we injected laser light into the end of the optical fiber, this configuration successfully worked as an area illuminator. However, the coherent nature of the laser light caused severe speckle noise. We evaluated the speckle contrast under darkness, and it varied from 80% to 23%, depending on the lens aperture used to capture the images of the illuminator. We glued an ultrasound generator to the optical fiber to introduce phase modulation for the light propagating inside the optical fiber. In this way, the speckle contrast was reduced by a factor of seven to four. Under room lighting, the speckle noise was made barely noticeable by turning on the ultrasound generator.
NASA Astrophysics Data System (ADS)
O'Shea, Tuathan P.; Garcia, Leo J.; Rosser, Karen E.; Harris, Emma J.; Evans, Philip M.; Bamber, Jeffrey C.
2014-04-01
This study investigates the use of a mechanically-swept 3D ultrasound (3D-US) probe for soft-tissue displacement monitoring during prostate irradiation, with emphasis on quantifying the accuracy relative to CyberKnife® x-ray fiducial tracking. An US phantom, implanted with x-ray fiducial markers was placed on a motion platform and translated in 3D using five real prostate motion traces acquired using the Calypso system. Motion traces were representative of all types of motion as classified by studying Calypso data for 22 patients. The phantom was imaged using a 3D swept linear-array probe (to mimic trans-perineal imaging) and, subsequently, the kV x-ray imaging system on CyberKnife. A 3D cross-correlation block-matching algorithm was used to track speckle in the ultrasound data. Fiducial and US data were each compared with known phantom displacement. Trans-perineal 3D-US imaging could track superior-inferior (SI) and anterior-posterior (AP) motion to ≤0.81 mm root-mean-square error (RMSE) at a 1.7 Hz volume rate. The maximum kV x-ray tracking RMSE was 0.74 mm, however the prostate motion was sampled at a significantly lower imaging rate (mean: 0.04 Hz). Initial elevational (right-left RL) US displacement estimates showed reduced accuracy but could be improved (RMSE <2.0 mm) using a correlation threshold in the ultrasound tracking code to remove erroneous inter-volume displacement estimates. Mechanically-swept 3D-US can track the major components of intra-fraction prostate motion accurately but exhibits some limitations. The largest US RMSE was for elevational (RL) motion. For the AP and SI axes, accuracy was sub-millimetre. It may be feasible to track prostate motion in 2D only. 3D-US also has the potential to improve high tracking accuracy for all motion types. It would be advisable to use US in conjunction with a small (˜2.0 mm) centre-of-mass displacement threshold in which case it would be possible to take full advantage of the accuracy and high imaging rate capability.
1981-09-01
brittle and photoelastic coatings, gages, grids, holography and speckle to solve two- and three-dimensional problems in elasticity, plasticity...weight by 10%. The efficiency coefficient is increased from 0.59 to 0.95. Tests with 4 brittle material show an increase in strength of 20%. An ideal...particularly useful for components made with brittle materials, or components made with ductile materials subjected to fatigue. Ple I Fa 441 ( .t
Liu, Xuan; Ramella-Roman, Jessica C.; Huang, Yong; Guo, Yuan; Kang, Jin U.
2013-01-01
In this study, we proposed a generic speckle simulation for optical coherence tomography (OCT) signal, by convolving the point spread function (PSF) of the OCT system with the numerically synthesized random sample field. We validated our model and used the simulation method to study the statistical properties of cross-correlation coefficients (XCC) between Ascans which have been recently applied in transverse motion analysis by our group. The results of simulation show that over sampling is essential for accurate motion tracking; exponential decay of OCT signal leads to an under estimate of motion which can be corrected; lateral heterogeneity of sample leads to an over estimate of motion for a few pixels corresponding to the structural boundary. PMID:23456001
In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images
NASA Astrophysics Data System (ADS)
Nillesen, M. M.; Lopata, R. G. P.; de Boode, W. P.; Gerrits, I. H.; Huisman, H. J.; Thijssen, J. M.; Kapusta, L.; de Korte, C. L.
2009-04-01
Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was validated quantitatively by comparing it with the CO values measured from the volume flow in the pulmonary artery. Relative bias varied between 0 and -17%, where the nominal accuracy of the flow meter is in the order of 10%. Assuming the CO measurements from the flow probe as a gold standard, excellent correlation (r = 0.99) was observed with the CO estimates obtained from image segmentation.
Applications of polarization speckle in skin cancer detection and monitoring
NASA Astrophysics Data System (ADS)
Lee, Tim K.; Tchvialeva, Lioudmila; Phillips, Jamie; Louie, Daniel C.; Zhao, Jianhua; Wang, Wei; Lui, Harvey; Kalia, Sunil
2018-01-01
Polarization speckle is a rapidly developed field. Unlike laser speckle, polarization speckle consists of stochastic interference patterns with spatially random polarizations, amplitudes and phases. We have been working in this exciting research field, developing techniques to generate polarization patterns from skin. We hypothesize that polarization speckle patterns could be used in biomedical applications, especially, for detecting and monitoring skin cancers, the most common neoplasmas for white populations around the world. This paper describes our effort in developing two polarization speckle devices. One of them captures the Stokes parameters So and S1 simultaneously, and another one captures all four Stokes parameters So, S1, S2, and S3 in one-shot, within milliseconds. Hence these two devices could be used in medical clinics and assessed skin conditions in-vivo. In order to validate our hypothesis, we conducted a series of three clinical studies. These are early pilot studies, and the results suggest that the devices have potential to detect and monitor skin cancers.
Predicting Cardiotoxic Effects of Carbon Monoxide Poisoning Using Speckle Tracking Echocardiography.
Saraçoğlu, Erhan; Vuruşkan, Ertan; Kılıç, Salih; Çekici, Yusuf; Onur, Bahaeddin; Arslan, Yavuz; Kılıç, Ertuğrul; Aykut, Ömer
2018-04-01
Carbon monoxide (CO) poisoning could cause significant cardiac injury. This study aimed to evaluate patients with CO poisoning by using speckle tracking echocardiography (STE), a potentially more sensitive technique, to identify left systolic ventricular dysfunction for the first time in the literature. Seventy-two patients who were exposed to CO poisoning were studied. Blood collection and echocardiography were performed at admission and after patients' discharge on days 10-15 (mean 12 days). Global longitudinal strain (GLS) and global circumferential strain (GCS) were calculated using STE. In order to find the normal strain levels and to compare it to the patient with CO poisoning, 35 healthy subjects were included in the study. Left ventricular ejection fraction was analyzed according to Simpson's method. Patients were divided into two groups based on their LVEF values. LVEF < 55%, Group 1 (n = 24); LVEF ≥ 55%, Group 2 (n = 48). The reduction in Group 1 strain levels decreased in correlation with LVEF (p < 0.001) while in Group 2, there were no significant changes in LVEF but strain levels were significantly reduced (p = 0.091; p < 0.001). Compared with the control group patients, admission GLS and GLC values of CO-poisoned patients were significantly low both in Group 1 and 2. On the contrary, no significant difference was observed when compared with follow-up GLS value. For prediction of CO cardiotoxicity, the cutoff value of GLS was ≥ - 19.1 with a sensitivity of 70.3% and a specificity of 100% [(AUC) 0.840, 95% (CI) 0.735-0.916; p < 0.001] in the ROC curve analyses. GLS was found as independent predictors of cardiotoxicity. Our study demonstrates the potential of using systolic strain values obtained using 2D-STE in determining cardiotoxicity due to CO poisoning. Speckle tracking echocardiography has the potential of demonstrating subtle LV systolic dysfunction even in CO poisoning patients with preserved EF.
Spalla, I; Locatelli, C; Zanaboni, A M; Brambilla, P; Bussadori, C
2016-05-01
Patent ductus arteriosus (PDA) is one of the most common congenital heart defects in dogs. Advanced echocardiographic techniques such as speckle-tracking echocardiography (STE) have not been extensively used to evaluate cardiac function in affected dogs. Advanced echocardiographic techniques are more sensitive than standard echocardiographic techniques in analyzing systolic function in dogs with PDA. Forty-four client-owned dogs: 34 dogs with PDA (preoperative evaluation) and 10 healthy sex- and weight-matched controls. Prospective study. Dogs were recruited over a 2-year period. Complete echocardiographic evaluation was performed, including conventional (end-diastolic volumes indexed to body surface area in B and M-mode [EDVIB /M ], end-systolic volumes indexed to body surface area in B and M-mode [ESVIB /M ], allometric scaling in diastole and systole [AlloD/S], pulmonary flow to systemic flow [Qp/Qs], ejection fraction [EF] and fractional shortening [FS]) and speckle-tracking echocardiography ([STE]: global longitudinal, radial and circumferential strain [S] and strain rate [SR]). Dogs with PDA had significantly different EDVIB /M , ESVIB /M , AlloD/S, Qp/Qs and all STE-derived parameters (global longitudinal S and SR, global circumferential S and SR, global radial S and SR)compared to healthy dogs. No correlation was found between standard techniques (EDVIB /M , ESVIB /M , AlloD/S, Qp/Qs) and STE-derived parameters (global longitudinal, circumferential and radial S and SR). Conventional parameters routinely used to assess systolic function (EF and FS) were not different between the groups; STE-derived parameters identified subtle changes in cardiac systolic function and contractility between the 2 groups of dogs. Based on these findings, STE may be a more appropriate tool to assess cardiac contractility in dogs with PDA. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Numerical Modeling of Three-Dimensional Fluid Flow with Phase Change
NASA Technical Reports Server (NTRS)
Esmaeeli, Asghar; Arpaci, Vedat
1999-01-01
We present a numerical method to compute phase change dynamics of three-dimensional deformable bubbles. The full Navier-Stokes and energy equations are solved for both phases by a front tracking/finite difference technique. The fluid boundary is explicitly tracked by discrete points that are connected by triangular elements to form a front that is used to keep the stratification of material properties sharp and to calculate the interfacial source terms. Two simulations are presented to show robustness of the method in handling complex phase boundaries. In the first case, growth of a vapor bubble in zero gravity is studied where large volume increase of the bubble is managed by adaptively increasing the front resolution. In the second case, growth of a bubble under high gravity is studied where indentation at the rear of the bubble results in a region of large curvature which challenges the front tracking in three dimensions.
Cong, Juan; Wang, Zhibin; Jin, Hong; Wang, Wugang; Gong, Kun; Meng, Yuanyuan; Lee, Yong
2016-11-10
The myocardial wall of the left ventricle is a complex, multilayered structure and is not homogenous. The aim of this study was to determine longitudinal strain (LS) in the three myocardial layers in normal pregnant women according to gestation proceedings. The advanced two-dimensional speckle tracking echocardiography (2D STE) was performed on 62 women during each pregnancy trimester and 6 to 9 weeks after delivery, while 30 age-matched, healthy, nonpregnant women served as controls. LS on endocardial, mid-myocardial and epicardial layers at 18 cardiac segments were measured. As gestation proceeded, all of layer-specific LS and global LS progressively decreased, which subsequently recovered postpartum (P < 0.05), and the LS gradient between inner and outer myocardium became greater, which reached its maximum in the late pregnancy. Peak systolic LS was the highest at endocardium and the lowest at epicardium, while the highest at the apical level and the lowest at the base (P < 0.05). In the early pregnancy and postpartum, LS at basal level was homogenous, meanwhile layer-specific LS showed significant differences at mid-ventricular and apical level throughout the progress of normal pregnancy (P < 0.05). Using 2D STE, three-layer assessment of LS can be performed in pregnant women and shall give us new insights into the quantitative analysis of global and regional LV function during pregnancy. Future studies on the detection of pregnancy related heart disease would require these parameters as reference values for each time point of a normal pregnancy.
Real time processor for array speckle interferometry
NASA Astrophysics Data System (ADS)
Chin, Gordon; Florez, Jose; Borelli, Renan; Fong, Wai; Miko, Joseph; Trujillo, Carlos
1989-02-01
The authors are constructing a real-time processor to acquire image frames, perform array flat-fielding, execute a 64 x 64 element two-dimensional complex FFT (fast Fourier transform) and average the power spectrum, all within the 25 ms coherence time for speckles at near-IR (infrared) wavelength. The processor will be a compact unit controlled by a PC with real-time display and data storage capability. This will provide the ability to optimize observations and obtain results on the telescope rather than waiting several weeks before the data can be analyzed and viewed with offline methods. The image acquisition and processing, design criteria, and processor architecture are described.
Real time processor for array speckle interferometry
NASA Technical Reports Server (NTRS)
Chin, Gordon; Florez, Jose; Borelli, Renan; Fong, Wai; Miko, Joseph; Trujillo, Carlos
1989-01-01
The authors are constructing a real-time processor to acquire image frames, perform array flat-fielding, execute a 64 x 64 element two-dimensional complex FFT (fast Fourier transform) and average the power spectrum, all within the 25 ms coherence time for speckles at near-IR (infrared) wavelength. The processor will be a compact unit controlled by a PC with real-time display and data storage capability. This will provide the ability to optimize observations and obtain results on the telescope rather than waiting several weeks before the data can be analyzed and viewed with offline methods. The image acquisition and processing, design criteria, and processor architecture are described.
Tan, Chaowei; Wang, Bo; Liu, Paul; Liu, Dong
2008-01-01
Wide field of view (WFOV) imaging mode obtains an ultrasound image over an area much larger than the real time window normally available. As the probe is moved over the region of interest, new image frames are combined with prior frames to form a panorama image. Image registration techniques are used to recover the probe motion, eliminating the need for a position sensor. Speckle patterns, which are inherent in ultrasound imaging, change, or become decorrelated, as the scan plane moves, so we pre-smooth the image to reduce the effects of speckle in registration, as well as reducing effects from thermal noise. Because we wish to track the movement of features such as structural boundaries, we use an adaptive mesh over the entire smoothed image to home in on areas with feature. Motion estimation using blocks centered at the individual mesh nodes generates a field of motion vectors. After angular correction of motion vectors, we model the overall movement between frames as a nonrigid deformation. The polygon filling algorithm for precise, persistence-based spatial compounding constructs the final speckle reduced WFOV image.
Hippocampal place-cell firing during movement in three-dimensional space
NASA Technical Reports Server (NTRS)
Knierim, J. J.; McNaughton, B. L.
2001-01-01
"Place" cells of the rat hippocampus are coupled to "head direction" cells of the thalamus and limbic cortex. Head direction cells are sensitive to head direction in the horizontal plane only, which leads to the question of whether place cells similarly encode locations in the horizontal plane only, ignoring the z axis, or whether they encode locations in three dimensions. This question was addressed by recording from ensembles of CA1 pyramidal cells while rats traversed a rectangular track that could be tilted and rotated to different three-dimensional orientations. Cells were analyzed to determine whether their firing was bound to the external, three-dimensional cues of the environment, to the two-dimensional rectangular surface, or to some combination of these cues. Tilting the track 45 degrees generally provoked a partial remapping of the rectangular surface in that some cells maintained their place fields, whereas other cells either gained new place fields, lost existing fields, or changed their firing locations arbitrarily. When the tilted track was rotated relative to the distal landmarks, most place fields remapped, but a number of cells maintained the same place field relative to the x-y coordinate frame of the laboratory, ignoring the z axis. No more cells were bound to the local reference frame of the recording apparatus than would be predicted by chance. The partial remapping demonstrated that the place cell system was sensitive to the three-dimensional manipulations of the recording apparatus. Nonetheless the results were not consistent with an explicit three-dimensional tuning of individual hippocampal neurons nor were they consistent with a model in which different sets of cells are tightly coupled to different sets of environmental cues. The results are most consistent with the statement that hippocampal neurons can change their "tuning functions" in arbitrary ways when features of the sensory input or behavioral context are altered. Understanding the rules that govern the remapping phenomenon holds promise for deciphering the neural circuitry underlying hippocampal function.
Ballo, Piercarlo; Nistri, Stefano; Bocelli, Arianna; Mele, Donato; Dini, Frank L; Galderisi, Maurizio; Zuppiroli, Alfredo; Mondillo, Sergio
2016-01-15
Assessment of left ventricular circumferential (LVcirc) systolic function by standard echocardiography can be performed by estimating midwall fractional shortening (mFS) and stress-corrected mFS (ScmFS). Their determination is based on spherical or cylindrical LV geometric models, which often yield discrepant values. We developed a new model based on a more realistic truncated ellipsoid (TE) LV shape, and explored the concordance between models among hypertensive patients. We also compared the relationships of different mFS and ScmFS estimates with indexes of LVcirc systolic strain. In 364 hypertensive subjects, mFS was determined using the spherical (mFSspher), cylindrical (mFScyl), and TE model (mFSTE). Corresponding values of ScmFSspher, ScmFScyl, and ScmFSTE were obtained. Global circumferential strain (GCS) and systolic strain rate (GCSR) were also measured by speckle tracking. The three models showed poor concordance for the estimation of mFS, with average differences ranging between 11% and 30% and wide limits of agreement. Similar results were found for ScmFS, where reclassification rates for the identification of abnormal LVcirc systolic function ranged between 18% and 29%. When tested against strain indexes, mFSTE and ScmFSTE showed the best correlations (R=0.81 and R=0.51, p<0.0001 for both) with GCS and GCSR. Multivariable analysis confirmed that mFSTE and ScmFSTE showed the strongest independent associations with LVcirc strain measures. Substantial discrepancies in LVcirc midwall systolic indexes exist between different models, supporting the need of model-specific normative data. The use of the TE model might provide indexes that show the best associations with established strain measures of LVcirc systolic function. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Landén Ludvigsson, Maria; Peterson, Gunnel; Jull, Gwendolen; Trygg, Johan; Peolsson, Anneli
2016-02-01
Approximately 50% of people with Whiplash Associated Disorders (WAD) report longstanding symptoms. The upper trapezius is commonly painful yet its mechanical properties are not fully understood. This study examined the deformation of different depths of the upper trapezius muscle during a scapular elevation task (shoulder shrugging) before and following loaded arm abduction. A cross-sectional case-control study of 36 people (26 female and 10 male, mean age 38 (SD 11)) with chronic WAD and 36 controls, matched for age and gender. Real-time ultrasound recordings of upper trapezius were taken during both scapular elevation tasks. Post-process speckle tracking analysis was undertaken of three different sections of the upper trapezius muscle (superficial, middle, deep). The WAD group had lower deformation of the superficial section of the upper trapezius compared to the control group in both concentric and eccentric phases of scapular elevation (p < 0.05) especially before the loaded arm abduction. After arm abduction, the deformation of the trapezius was reduced in both groups but only significantly in the WAD-group (p = 0.03). Within-group analysis revealed that the control group least engaged the deep section of upper trapezius during the task (p < 0.01). This study, measuring mechanical deformation of the upper trapezius during a scapular elevation task indicates that persons with WAD may display different patterns in engagement of the muscle sections than those in the control group. Further research is needed to replicate and understand the reasons for and implications of this possible change in motor strategy within upper trapezius. Clinical Trials.gov, Number: NCT01547624. Copyright © 2015 Elsevier Ltd. All rights reserved.
DeVore, Greggory R; Klas, Berthold; Satou, Gary; Sklansky, Mark
2018-03-14
The purpose of this study was to measure the fractional area change (FAC) of the right and left ventricles in normal fetal hearts between 20 and 40 weeks of gestation using speckle-tracking software. The 4-chamber view of the fetal heart was obtained in 200 control fetuses between 20 and 40 weeks of gestation. The FAC was computed from the ventricular areas [((end-diastolic area) - (end-systolic area)/(end-diastolic area)) x 100] for the right and left ventricles and regressed against 7 independent biometric and age variables. The FAC was correlated with longitudinal fractional shortening (LFS) [((end-diastolic longitudinal length) - (end-systolic longitudinal length) /(end-diastolic longitudinal length)) x 100] obtained from the mid ventricular basal-apical lengths of the right and left ventricular chambers and the transverse fractional shortening (TFS) [((end-diastolic transverse length) - (end-systolic transverse length)/(end-diastolic transverse length)) x 100] from three transverse positions (base, mid, apical) located within each ventricular chamber. To evaluate potential clinical utility, the FAC, LFS, and TFS results were examined in 9 fetuses with congenital heart defects (CHD). Regression analysis demonstrated significant associations between the FAC and the biometric and age independent variables (R 2 = 0.13 - 0.15). The FAC was significantly correlated with the LFS (R 2 =0.18 to 0.28) and TFS (R 2 = 0.13 to 0.33). The 9 fetuses with CHD illustrated the interrelationship between the FAC, LFS, and TFS when identifying abnormal ventricular function. This study reports results from measuring the FAC of the right and left ventricles, and demonstrates a correlation with longitudinal fractional shortening (LFS) and transverse fractional shortening (TFS). This article is protected by copyright. All rights reserved.
New techniques for fluorescence background rejection in microscopy and endoscopy
NASA Astrophysics Data System (ADS)
Ventalon, Cathie
2009-03-01
Confocal microscopy is a popular technique in the bioimaging community, mainly because it provides optical sectioning. However, its standard implementation requires 3-dimensional scanning of focused illumination throughout the sample. Efficient non-scanning alternatives have been implemented, among which the simple and well-established incoherent structured illumination microscopy (SIM) [1]. We recently proposed a similar technique, called Dynamic Speckle Illumination (DSI) microscopy, wherein the incoherent grid illumination pattern is replaced with a coherent speckle illumination pattern from a laser, taking advantage of the fact that speckle contrast is highly maintained in a scattering media, making the technique well adapted to tissue imaging [2]. DSI microscopy relies on the illumination of a sample with a sequence of dynamic speckle patterns and an image processing algorithm based only on an a priori knowledge of speckle statistics. The choice of this post-processing algorithm is crucial to obtain a good sectioning strength: in particular, we developed a novel post-processing algorithm based one wavelet pre-filtering of the raw images and obtained near-confocal fluorescence sectioning in a mouse brain labeled with GFP, with a good image quality maintained throughout a depth of ˜100 μm [3]. In the purpose of imaging fluorescent tissue at higher depth, we recently applied structured illumination to endoscopy. We used a similar set-up wherein the illumination pattern (a one-dimensional grid) is transported to the sample with an imaging fiber bundle with miniaturized objective and the fluorescence image is collected through the same bundle. Using a post-processing algorithm similar to the one previously described [3], we obtained high-quality images of a fluorescein-labeled rat colonic mucosa [4], establishing the potential of our endomicroscope for bioimaging applications. [4pt] Ref: [0pt] [1] M. A. A. Neil et al, Opt. Lett. 22, 1905 (1997) [0pt] [2] C. Ventalon et al, Opt. Lett. 30, 3350 (2005) [0pt] [3] C. Ventalon et al, Opt. Lett. 32, 1417 (2007) [0pt] [4] N. Bozinovic et al, Opt. Express 16, 8016 (2008)
Fractality of pulsatile flow in speckle images
NASA Astrophysics Data System (ADS)
Nemati, M.; Kenjeres, S.; Urbach, H. P.; Bhattacharya, N.
2016-05-01
The scattering of coherent light from a system with underlying flow can be used to yield essential information about dynamics of the process. In the case of pulsatile flow, there is a rapid change in the properties of the speckle images. This can be studied using the standard laser speckle contrast and also the fractality of images. In this paper, we report the results of experiments performed to study pulsatile flow with speckle images, under different experimental configurations to verify the robustness of the techniques for applications. In order to study flow under various levels of complexity, the measurements were done for three in-vitro phantoms and two in-vivo situations. The pumping mechanisms were varied ranging from mechanical pumps to the human heart for the in vivo case. The speckle images were analyzed using the techniques of fractal dimension and speckle contrast analysis. The results of these techniques for the various experimental scenarios were compared. The fractal dimension is a more sensitive measure to capture the complexity of the signal though it was observed that it is also extremely sensitive to the properties of the scattering medium and cannot recover the signal for thicker diffusers in comparison to speckle contrast.
Speckle Interferometry with the OCA Kuhn 22" Telescope
NASA Astrophysics Data System (ADS)
Wasson, Rick
2018-04-01
Speckle interferometry measurements of double stars were made in 2015 and 2016, using the Kuhn 22-inch classical Cassegrain telescope of the Orange County Astronomers, a Point Grey Blackfly CMOS camera, and three interference filters. 272 observations are reported for 177 systems, with separations ranging from 0.29" to 2.9". Data reduction was by means of the REDUC and Speckle Tool Box programs. Equipment, observing procedures, calibration, data reduction, and analysis are described, and unusual results for 11 stars are discussed in detail.
Computer-generated 3D ultrasound images of the carotid artery
NASA Technical Reports Server (NTRS)
Selzer, Robert H.; Lee, Paul L.; Lai, June Y.; Frieden, Howard J.; Blankenhorn, David H.
1989-01-01
A method is under development to measure carotid artery lesions from a computer-generated three-dimensional ultrasound image. For each image, the position of the transducer in six coordinates (x, y, z, azimuth, elevation, and roll) is recorded and used to position each B-mode picture element in its proper spatial position in a three-dimensional memory array. After all B-mode images have been assembled in the memory, the three-dimensional image is filtered and resampled to produce a new series of parallel-plane two-dimensional images from which arterial boundaries are determined using edge tracking methods.
Computer-generated 3D ultrasound images of the carotid artery
NASA Astrophysics Data System (ADS)
Selzer, Robert H.; Lee, Paul L.; Lai, June Y.; Frieden, Howard J.; Blankenhorn, David H.
A method is under development to measure carotid artery lesions from a computer-generated three-dimensional ultrasound image. For each image, the position of the transducer in six coordinates (x, y, z, azimuth, elevation, and roll) is recorded and used to position each B-mode picture element in its proper spatial position in a three-dimensional memory array. After all B-mode images have been assembled in the memory, the three-dimensional image is filtered and resampled to produce a new series of parallel-plane two-dimensional images from which arterial boundaries are determined using edge tracking methods.
Nagare, Mukund B; Patil, Bhushan D; Holambe, Raghunath S
2017-02-01
B-Mode ultrasound images are degraded by inherent noise called Speckle, which creates a considerable impact on image quality. This noise reduces the accuracy of image analysis and interpretation. Therefore, reduction of speckle noise is an essential task which improves the accuracy of the clinical diagnostics. In this paper, a Multi-directional perfect-reconstruction (PR) filter bank is proposed based on 2-D eigenfilter approach. The proposed method used for the design of two-dimensional (2-D) two-channel linear-phase FIR perfect-reconstruction filter bank. In this method, the fan shaped, diamond shaped and checkerboard shaped filters are designed. The quadratic measure of the error function between the passband and stopband of the filter has been used an objective function. First, the low-pass analysis filter is designed and then the PR condition has been expressed as a set of linear constraints on the corresponding synthesis low-pass filter. Subsequently, the corresponding synthesis filter is designed using the eigenfilter design method with linear constraints. The newly designed 2-D filters are used in translation invariant pyramidal directional filter bank (TIPDFB) for reduction of speckle noise in ultrasound images. The proposed 2-D filters give better symmetry, regularity and frequency selectivity of the filters in comparison to existing design methods. The proposed method is validated on synthetic and real ultrasound data which ensures improvement in the quality of ultrasound images and efficiently suppresses the speckle noise compared to existing methods.
NASA Astrophysics Data System (ADS)
Yilmaz, Hasan
2016-03-01
Structured illumination enables high-resolution fluorescence imaging of nanostructures [1]. We demonstrate a new high-resolution fluorescence imaging method that uses a scattering layer with a high-index substrate as a solid immersion lens [2]. Random scattering of coherent light enables a speckle pattern with a very fine structure that illuminates the fluorescent nanospheres on the back surface of the high-index substrate. The speckle pattern is raster-scanned over the fluorescent nanospheres using a speckle correlation effect known as the optical memory effect. A series of standard-resolution fluorescence images per each speckle pattern displacement are recorded by an electron-multiplying CCD camera using a commercial microscope objective. We have developed a new phase-retrieval algorithm to reconstruct a high-resolution, wide-field image from several standard-resolution wide-field images. We have introduced phase information of Fourier components of standard-resolution images as a new constraint in our algorithm which discards ambiguities therefore ensures convergence to a unique solution. We demonstrate two-dimensional fluorescence images of a collection of nanospheres with a deconvolved Abbe resolution of 116 nm and a field of view of 10 µm × 10 µm. Our method is robust against optical aberrations and stage drifts, therefore excellent for imaging nanostructures under ambient conditions. [1] M. G. L. Gustafsson, J. Microsc. 198, 82-87 (2000). [2] H. Yilmaz, E. G. van Putten, J. Bertolotti, A. Lagendijk, W. L. Vos, and A. P. Mosk, Optica 2, 424-429 (2015).
Afonso, Luis; Kondur, Ashok; Simegn, Mengistu; Niraj, Ashutosh; Hari, Pawan; Kaur, Ramanjit; Ramappa, Preeti; Pradhan, Jyotiranjan; Bhandare, Deepti; Williams, Kim A; Zalawadiya, Sandip; Pinheiro, Aurelio; Abraham, Theodore P
2012-01-01
This study was designed to examine the utility of two-dimensional strain (2DS) or speckle tracking imaging to typify functional adaptations of the left ventricle in variant forms of left ventricular hypertrophy (LVH). Cross-sectional study. Urban tertiary care academic medical centres. A total of 129 subjects, 56 with hypertrophic cardiomyopathy (HCM), 34 with hypertensive left ventricular hypertrophy (H-LVH), 27 professional athletes with LVH (AT-LVH) and 12 healthy controls in sinus rhythm with preserved left ventricular systolic function. Conventional echocardiographic and tissue Doppler examinations were performed in all study subjects. Bi-dimensional acquisitions were analysed to map longitudinal systolic strain (automated function imaging, AFI, GE Healthcare, Waukesha, Wisconsin, USA) from apical views. Subjects with HCM had significantly lower regional and average global peak longitudinal systolic strain (GLS-avg) compared with controls and other forms of LVH. Strain dispersion index, a measure of regional contractile heterogeneity, was higher in HCM compared with the rest of the groups. On receiver operator characteristics analysis, GLS-avg had excellent discriminatory ability to distinguish HCM from H-LVH area under curve (AUC) (0.893, p<0.001) or AT-LVH AUC (0.920, p<0.001). Tissue Doppler and LV morphological parameters were better suited to differentiate the athlete heart from HCM. 2DS (AFI) allows rapid characterisation of regional and global systolic function and may have the potential to differentiate HCM from variant forms of LVH.
NASA Astrophysics Data System (ADS)
Sims-Waterhouse, D.; Bointon, P.; Piano, S.; Leach, R. K.
2017-06-01
In this paper we show that, by using a photogrammetry system with and without laser speckle, a large range of additive manufacturing (AM) parts with different geometries, materials and post-processing textures can be measured to high accuracy. AM test artefacts have been produced in three materials: polymer powder bed fusion (nylon-12), metal powder bed fusion (Ti-6Al-4V) and polymer material extrusion (ABS plastic). Each test artefact was then measured with the photogrammetry system in both normal and laser speckle projection modes and the resulting point clouds compared with the artefact CAD model. The results show that laser speckle projection can result in a reduction of the point cloud standard deviation from the CAD data of up to 101 μm. A complex relationship with surface texture, artefact geometry and the laser speckle projection is also observed and discussed.
Reconstructing the flight kinematics of swarming and mating in wild mosquitoes
Butail, Sachit; Manoukis, Nicholas; Diallo, Moussa; Ribeiro, José M.; Lehmann, Tovi; Paley, Derek A.
2012-01-01
We describe a novel tracking system for reconstructing three-dimensional tracks of individual mosquitoes in wild swarms and present the results of validating the system by filming swarms and mating events of the malaria mosquito Anopheles gambiae in Mali. The tracking system is designed to address noisy, low frame-rate (25 frames per second) video streams from a stereo camera system. Because flying A. gambiae move at 1–4 m s−1, they appear as faded streaks in the images or sometimes do not appear at all. We provide an adaptive algorithm to search for missing streaks and a likelihood function that uses streak endpoints to extract velocity information. A modified multi-hypothesis tracker probabilistically addresses occlusions and a particle filter estimates the trajectories. The output of the tracking algorithm is a set of track segments with an average length of 0.6–1 s. The segments are verified and combined under human supervision to create individual tracks up to the duration of the video (90 s). We evaluate tracking performance using an established metric for multi-target tracking and validate the accuracy using independent stereo measurements of a single swarm. Three-dimensional reconstructions of A. gambiae swarming and mating events are presented. PMID:22628212
Three-dimensional laser radar modeling
NASA Astrophysics Data System (ADS)
Steinvall, Ove K.; Carlsson, Tomas
2001-09-01
Laser radars have the unique capability to give intensity and full 3-D images of an object. Doppler lidars can give velocity and vibration characteristics of an objects. These systems have many civilian and military applications such as terrain modelling, depth sounding, object detection and classification as well as object positioning. In order to derive the signal waveform from the object one has to account for the laser pulse time characteristics, media effects such as the atmospheric attenuation and turbulence effects or scattering properties, the target shape and reflection (BRDF), speckle noise together with the receiver and background noise. Finally the type of waveform processing (peak detection, leading edge etc.) is needed to model the sensor output to be compared with observations. We have developed a computer model which models performance of a 3-D laser radar. We will give examples of signal waveforms generated from model different targets calculated by integrating the laser beam profile in space and time over the target including reflection characteristics during different speckle and turbulence conditions. The result will be of help when designing and using new laser radar systems. The importance of different type of signal processing of the waveform in order to fulfil performance goals will be shown.
Speckle Filtering of GF-3 Polarimetric SAR Data with Joint Restriction Principle.
Xie, Jinwei; Li, Zhenfang; Zhou, Chaowei; Fang, Yuyuan; Zhang, Qingjun
2018-05-12
Polarimetric SAR (PolSAR) scattering characteristics of imagery are always obtained from the second order moments estimation of multi-polarization data, that is, the estimation of covariance or coherency matrices. Due to the extra-paths that signal reflected from separate scatterers within the resolution cell has to travel, speckle noise always exists in SAR images and has a severe impact on the scattering performance, especially on single look complex images. In order to achieve high accuracy in estimating covariance or coherency matrices, three aspects are taken into consideration: (1) the edges and texture of the scene are distinct after speckle filtering; (2) the statistical characteristic should be similar to the object pixel; and (3) the polarimetric scattering signature should be preserved, in addition to speckle reduction. In this paper, a joint restriction principle is proposed to meet the requirement. Three different restriction principles are introduced to the processing of speckle filtering. First, a new template, which is more suitable for the point or line targets, is designed to ensure the morphological consistency. Then, the extent sigma filter is used to restrict the pixels in the template aforementioned to have an identical statistic characteristic. At last, a polarimetric similarity factor is applied to the same pixels above, to guarantee the similar polarimetric features amongst the optional pixels. This processing procedure is named as speckle filtering with joint restriction principle and the approach is applied to GF-3 polarimetric SAR data acquired in San Francisco, CA, USA. Its effectiveness of keeping the image sharpness and preserving the scattering mechanism as well as speckle reduction is validated by the comparison with boxcar filters and refined Lee filter.
Lu, Min; Wang, Shengjia; Aulbach, Laura; Koch, Alexander W
2016-08-01
This paper suggests the use of adjustable aperture multiplexing (AAM), a method which is able to introduce multiple tunable carrier frequencies into a three-beam electronic speckle pattern interferometer to measure the out-of-plane displacement and its first-order derivative simultaneously. In the optical arrangement, two single apertures are located in the object and reference light paths, respectively. In cooperation with two adjustable mirrors, virtual images of the single apertures construct three pairs of virtual double apertures with variable aperture opening sizes and aperture distances. By setting the aperture parameter properly, three tunable spatial carrier frequencies are produced within the speckle pattern and completely separate the information of three interferograms in the frequency domain. By applying the inverse Fourier transform to a selected spectrum, its corresponding phase difference distribution can thus be evaluated. Therefore, we can obtain the phase map due to the deformation as well as its slope of the test surface from two speckle patterns which are recorded at different loading events. By this means, simultaneous and dynamic measurements are realized. AAM has greatly simplified the measurement system, which contributes to improving the system stability and increasing the system flexibility and adaptability to various measurement requirements. This paper presents the AAM working principle, the phase retrieval using spatial carrier frequency, and preliminary experimental results.
Khan, Fakhar Z; Virdee, Mumohan S; Palmer, Christopher R; Pugh, Peter J; O'Halloran, Denis; Elsik, Maros; Read, Philip A; Begley, David; Fynn, Simon P; Dutka, David P
2012-04-24
This study sought to assess the impact of targeted left ventricular (LV) lead placement on outcomes of cardiac resynchronization therapy (CRT). Placement of the LV lead to the latest sites of contraction and away from the scar confers the best response to CRT. We conducted a randomized, controlled trial to compare a targeted approach to LV lead placement with usual care. A total of 220 patients scheduled for CRT underwent baseline echocardiographic speckle-tracking 2-dimensional radial strain imaging and were then randomized 1:1 into 2 groups. In group 1 (TARGET [Targeted Left Ventricular Lead Placement to Guide Cardiac Resynchronization Therapy]), the LV lead was positioned at the latest site of peak contraction with an amplitude of >10% to signify freedom from scar. In group 2 (control) patients underwent standard unguided CRT. Patients were classified by the relationship of the LV lead to the optimal site as concordant (at optimal site), adjacent (within 1 segment), or remote (≥2 segments away). The primary endpoint was a ≥15% reduction in LV end-systolic volume at 6 months. Secondary endpoints were clinical response (≥1 improvement in New York Heart Association functional class), all-cause mortality, and combined all-cause mortality and heart failure-related hospitalization. The groups were balanced at randomization. In the TARGET group, there was a greater proportion of responders at 6 months (70% vs. 55%, p = 0.031), giving an absolute difference in the primary endpoint of 15% (95% confidence interval: 2% to 28%). Compared with controls, TARGET patients had a higher clinical response (83% vs. 65%, p = 0.003) and lower rates of the combined endpoint (log-rank test, p = 0.031). Compared with standard CRT treatment, the use of speckle-tracking echocardiography to the target LV lead placement yields significantly improved response and clinical status and lower rates of combined death and heart failure-related hospitalization. (Targeted Left Ventricular Lead Placement to Guide Cardiac Resynchronization Therapy [TARGET] study); ISRCTN19717943). Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Childhood obesity: impact on cardiac geometry and function.
Mangner, Norman; Scheuermann, Kathrin; Winzer, Ephraim; Wagner, Isabel; Hoellriegel, Robert; Sandri, Marcus; Zimmer, Marion; Mende, Meinhard; Linke, Axel; Kiess, Wieland; Schuler, Gerhard; Körner, Antje; Erbs, Sandra
2014-12-01
The aim of our study was to assess geometric and functional changes of the heart in obese compared with nonobese children and adolescents. Obesity in children and adolescents has increased over the past decades and is considered a strong risk factor for future cardiovascular morbidity and mortality. Obesity has been associated with myocardial structural alterations that may influence cardiac mechanics. We prospectively recruited 61 obese (13.5 ± 2.7 years of age, 46% male sex, SD score body mass index, 2.52 ± 0.60) and 40 nonobese (14.1 ± 2.8 years of age, 50% male sex, SD score body mass index, -0.33 ± 0.83) consecutive, nonselected Caucasian children and adolescents. A standardized 2-dimensional (2D) echocardiography and 2D speckle-tracking analysis was performed in all children. Furthermore, blood chemistry including lipid and glucose metabolism was assessed in all children. Compared with nonobese children, blood pressure, low-density lipoprotein cholesterol, and parameters of glucose metabolism were significantly increased in obese children, whereas high-density lipoprotein cholesterol was significantly lower. Compared with nonobese children, obese children were characterized by enlarged left- and right-sided cardiac chambers, thicker left ventricular walls, and, consequently, increased left ventricular mass. Despite a comparable left ventricular ejection fraction, decreased tissue Doppler-derived peak systolic velocity and regional basoseptal strain were found in obese children compared with nonobese children. Beyond that, 2D speckle tracking-derived longitudinal (-18.2 ± 2.0 vs. -20.5 ± 2.3, p < 0.001) and circumferential (-17.0 ± 2.7 vs. -19.5 ± 2.9, p < 0.001) strain of the left ventricle was reduced in obese children compared with nonobese children. Diastolic function was also impaired in obese compared with nonobese children. Both longitudinal strain and circumferential strain were independently associated with obesity. The results of this study demonstrate that childhood obesity is associated with significant changes in myocardial geometry and function, indicating an early onset of potentially unfavorable alterations in the myocardium. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Sotomi, Yohei; Okamura, Atsunori; Iwakura, Katsuomi; Date, Motoo; Nagai, Hiroyuki; Yamasaki, Tomohiro; Koyama, Yasushi; Inoue, Koichi; Sakata, Yasushi; Fujii, Kenshi
2017-06-01
The present study aimed to assess the mechanisms of effects of percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) from two different aspects: left ventricular (LV) systolic function assessed by two-dimensional speckle tracking echocardiography (2D-STE) and electrical stability evaluated by late potential on signal-averaged electrocardiogram (SAECG). We conducted a prospective observational study with consecutive CTO-PCI patients. 2D-STE and SAECG were performed before PCI, and after 1-day and 3-months of procedure. 2D-STE computed global longitudinal strain (GLS) and regional longitudinal strain (RLS) in CTO area, collateral blood-supplying donor artery area, and non-CTO/non-donor area. A total of 37 patients (66 ± 11 years, 78% male) were analyzed. RLS in CTO and donor areas and GLS were significantly improved 1-day after the procedure, but these improvements diminished during 3 months. The improvement of RLS in donor area remained significant after 3-months the index procedure (pre-PCI -13.4 ± 4.8% vs. post-3M -15.1 ± 4.5%, P = 0.034). RLS in non-CTO/non-donor area and LV ejection fraction were not influenced. Mitral annulus velocity was improved at 3-month follow-up (5.0 ± 1.4 vs. 5.6 ± 1.7 cm/s, P = 0.049). Before the procedure, 12 patients (35%) had a late potential. All components of the late potential (filtered QRS duration, root-mean-square voltage in the terminal 40 ms, and duration of the low amplitude signal <40 μV) were not improved. CTO-PCI improved RLS in the donor area at 3-month follow-up without changes of LV ejection fraction. Although higher prevalence of late potential in the current population compared to healthy population was observed, late potential as a surrogate of arrhythmogenic substrate was not influenced by CTO-PCI.
Nagai, Tomoo; Hamabe, Akira; Arakawa, Junko; Tabata, Hirotsugu; Nishioka, Toshihiko
2017-11-01
The purpose of this study was to evaluate left ventricular (LV) deformation and LV dyssynchrony in patients with Wolff-Parkinson-White (WPW) syndrome and to identify the factors that affect the efficacy of radiofrequency catheter ablation (RFCA). Thirty patients (26 men, mean age 40 ± 12 years) with WPW syndrome were prospectively recruited for this study. They underwent 2-dimensional transthoracic echocardiography with speckle tracking analysis before RFCA and again within 48 hours after RFCA. Control group consisted of 15 age and sex-matched healthy volunteers. The patients had significantly lower LV ejection fraction (LVEF), global longitudinal strain (S l ), and global circumferential strain (S c ) compared with healthy controls (64% ± 8% vs 68% ± 5%, P = .049; -17.6% ± 3.2% vs -19.9% ± 3.3%, P = .037, -15.2% ± 2.5% vs -19.4% ± 2.5%, P < .0001, respectively). Patients had a significantly higher dyssynchrony index relative to healthy controls (58.4 ± 49.0 ms vs 36.4 ± 31.1 ms, P = .031). After RFCA, there was a significant increase in LVEF and global S c (68% ± 8% vs 64% ± 8%, P = .005; -17.3% ± 2.0% vs -15.2% ± 2.5%, P < .0001, respectively), along with a significant decrease in the dyssynchrony index (36.9 ± 36.3 ms vs 58.4 ± ms, P < .001) relative to the baseline values. Logistic regression revealed that the baseline dyssynchrony index was a predictor of LVEF improvement after RFCA (odds ratio: 1.060, P = .038). In WPW syndrome, impaired LV circumferential deformation can be restored by RFCA with concomitant improvement in LV dyssynchrony and LVEF. © 2017, Wiley Periodicals, Inc.
Federico, Alejandro; Kaufmann, Guillermo H
2006-03-20
We propose a novel approach to retrieving the phase map coded by a single closed-fringe pattern in digital speckle pattern interferometry, which is based on the estimation of the local sign of the quadrature component. We obtain the estimate by calculating the local orientation of the fringes that have previously been denoised by a weighted smoothing spline method. We carry out the procedure of sign estimation by determining the local abrupt jumps of size pi in the orientation field of the fringes and by segmenting the regions defined by these jumps. The segmentation method is based on the application of two-dimensional active contours (snakes), with which one can also estimate absent jumps, i.e., those that cannot be detected from the local orientation of the fringes. The performance of the proposed phase-retrieval technique is evaluated for synthetic and experimental fringes and compared with the results obtained with the spiral-phase- and Fourier-transform methods.
Lateral velocity estimation bias due to beamforming delay errors (Conference Presentation)
NASA Astrophysics Data System (ADS)
Rodriguez-Molares, Alfonso; Fadnes, Solveig; Swillens, Abigail; Løvstakken, Lasse
2017-03-01
An artefact has recently been reported [1,2] in the estimation of the lateral blood velocity using speckle tracking. This artefact shows as a net velocity bias in presence of strong spatial velocity gradients such as those that occur at the edges of the filling jets in the heart. Even though this artifact has been found both in vitro and in simulated data, its causes are still undescribed. Here we demonstrate that a potential source of this artefact can be traced to smaller errors in the beamforming setup. By inserting a small offset in the beamforming delay, one can artificially create a net lateral movement in the speckle in areas of high velocity gradient. That offset does not have a strong impact in the image quality and can easily go undetected.
Regan, Caitlin; Hayakawa, Carole; Choi, Bernard
2017-12-01
Due to its simplicity and low cost, laser speckle imaging (LSI) has achieved widespread use in biomedical applications. However, interpretation of the blood-flow maps remains ambiguous, as LSI enables only limited visualization of vasculature below scattering layers such as the epidermis and skull. Here, we describe a computational model that enables flexible in-silico study of the impact of these factors on LSI measurements. The model uses Monte Carlo methods to simulate light and momentum transport in a heterogeneous tissue geometry. The virtual detectors of the model track several important characteristics of light. This model enables study of LSI aspects that may be difficult or unwieldy to address in an experimental setting, and enables detailed study of the fundamental origins of speckle contrast modulation in tissue-specific geometries. We applied the model to an in-depth exploration of the spectral dependence of speckle contrast signal in the skin, the effects of epidermal melanin content on LSI, and the depth-dependent origins of our signal. We found that LSI of transmitted light allows for a more homogeneous integration of the signal from the entire bulk of the tissue, whereas epi-illumination measurements of contrast are limited to a fraction of the light penetration depth. We quantified the spectral depth dependence of our contrast signal in the skin, and did not observe a statistically significant effect of epidermal melanin on speckle contrast. Finally, we corroborated these simulated results with experimental LSI measurements of flow beneath a thin absorbing layer. The results of this study suggest the use of LSI in the clinic to monitor perfusion in patients with different skin types, or inhomogeneous epidermal melanin distributions.
Regan, Caitlin; Hayakawa, Carole; Choi, Bernard
2017-01-01
Due to its simplicity and low cost, laser speckle imaging (LSI) has achieved widespread use in biomedical applications. However, interpretation of the blood-flow maps remains ambiguous, as LSI enables only limited visualization of vasculature below scattering layers such as the epidermis and skull. Here, we describe a computational model that enables flexible in-silico study of the impact of these factors on LSI measurements. The model uses Monte Carlo methods to simulate light and momentum transport in a heterogeneous tissue geometry. The virtual detectors of the model track several important characteristics of light. This model enables study of LSI aspects that may be difficult or unwieldy to address in an experimental setting, and enables detailed study of the fundamental origins of speckle contrast modulation in tissue-specific geometries. We applied the model to an in-depth exploration of the spectral dependence of speckle contrast signal in the skin, the effects of epidermal melanin content on LSI, and the depth-dependent origins of our signal. We found that LSI of transmitted light allows for a more homogeneous integration of the signal from the entire bulk of the tissue, whereas epi-illumination measurements of contrast are limited to a fraction of the light penetration depth. We quantified the spectral depth dependence of our contrast signal in the skin, and did not observe a statistically significant effect of epidermal melanin on speckle contrast. Finally, we corroborated these simulated results with experimental LSI measurements of flow beneath a thin absorbing layer. The results of this study suggest the use of LSI in the clinic to monitor perfusion in patients with different skin types, or inhomogeneous epidermal melanin distributions. PMID:29296499
Three-dimensional reconstruction of the fast-start swimming kinematics of densely schooling fish
Paley, Derek A.
2012-01-01
Information transmission via non-verbal cues such as a fright response can be quantified in a fish school by reconstructing individual fish motion in three dimensions. In this paper, we describe an automated tracking framework to reconstruct the full-body trajectories of densely schooling fish using two-dimensional silhouettes in multiple cameras. We model the shape of each fish as a series of elliptical cross sections along a flexible midline. We estimate the size of each ellipse using an iterated extended Kalman filter. The shape model is used in a model-based tracking framework in which simulated annealing is applied at each step to estimate the midline. Results are presented for eight fish with occlusions. The tracking system is currently being used to investigate fast-start behaviour of schooling fish in response to looming stimuli. PMID:21642367
Gateau, Jérôme; Rigneault, Hervé; Guillon, Marc
2017-01-27
Intensity maxima and zeros of speckle patterns obtained behind a diffuser are experimentally interchanged by applying a spiral phase delay of charge ±1 to the impinging coherent beam. This transform arises from the expectation that tightly focused beams, which have a planar wave front around the focus, are so changed into vortex beams and vice versa. The statistics of extrema locations and the intensity distribution of the so-generated "complementary" patterns are characterized by numerical simulations. It is demonstrated experimentally that the incoherent superposition of the three "complementary speckle patterns" yield a synthetic speckle grain size enlarged by a factor of sqrt[3]. A cyclic permutation of optical vortices and intensity maxima is unexpectedly observed and discussed.
The Stellar Cusp in the Galactic Center: Three-Dimensional Orbits of Stars
NASA Astrophysics Data System (ADS)
Chappell, Samantha; Ghez, Andrea M.; Boehle, Anna; Yelda, Sylvana; Sitarski, Breann; Witzel, Gunther; Do, Tuan; Lu, Jessica R.; Morris, Mark; Becklin, Eric E.
2015-01-01
We present new findings from our long term study of the nuclear star cluster around the Galaxy's central supermassive blackhole (SMBH). Measurements where made using speckle and laser guided adaptive optics imaging and integral field spectroscopy on the Keck telescopes. We report 13 new measurable accelerating sources around the SMBH, down to ~17 mag in K band, only 4 of which are known to be young stars, the rest are either known to be old stars or have yet to be spectral typed. Thus we more than double the number of measured accelerations for the known old stars and unknown spectral type population (increasing the number from 6 to 15). Previous observations suggest a flat density profile of late-type stars, contrary to the theorized Bahcall-Wolf cusp (Bahcall & Wolf 1976, 1977; Buchholz et al. 2009; Do et al. 2009; Bartko et al. 2010). With three-dimensional orbits of significantly accelerating sources, we will be able to better characterize the stellar cusp in the Galactic center, including the slope of the stellar density profile.
Multisensor fusion for 3D target tracking using track-before-detect particle filter
NASA Astrophysics Data System (ADS)
Moshtagh, Nima; Romberg, Paul M.; Chan, Moses W.
2015-05-01
This work presents a novel fusion mechanism for estimating the three-dimensional trajectory of a moving target using images collected by multiple imaging sensors. The proposed projective particle filter avoids the explicit target detection prior to fusion. In projective particle filter, particles that represent the posterior density (of target state in a high-dimensional space) are projected onto the lower-dimensional observation space. Measurements are generated directly in the observation space (image plane) and a marginal (sensor) likelihood is computed. The particles states and their weights are updated using the joint likelihood computed from all the sensors. The 3D state estimate of target (system track) is then generated from the states of the particles. This approach is similar to track-before-detect particle filters that are known to perform well in tracking dim and stealthy targets in image collections. Our approach extends the track-before-detect approach to 3D tracking using the projective particle filter. The performance of this measurement-level fusion method is compared with that of a track-level fusion algorithm using the projective particle filter. In the track-level fusion algorithm, the 2D sensor tracks are generated separately and transmitted to a fusion center, where they are treated as measurements to the state estimator. The 2D sensor tracks are then fused to reconstruct the system track. A realistic synthetic scenario with a boosting target was generated, and used to study the performance of the fusion mechanisms.
NASA Astrophysics Data System (ADS)
Wang, Hongbei; Cui, Xiaoqian; Feng, Chunlei; Li, Yuanbo; Zhao, Mengge; Luo, Guangnan; Ding, Hongbin
2017-11-01
Plasma Facing Components (PFCs) in a magnetically confined fusion plasma device will be exposed to high heat load and particle fluxes, and it would cause PFCs' surface morphology to change due to material erosion and redeposition from plasma wall interactions. The state of PFCs' surface condition will seriously affect the performance of long-pulse or steady state plasma discharge in a tokamak; it will even constitute an enormous threat to the operation and the safety of fusion plasma devices. The PFCs' surface morphology evolution measurement could provide important information about PFCs' real-time status or damage situation and it would help to a better understanding of the plasma wall interaction process and mechanism. Meanwhile through monitoring the distribution of dust deposition in a tokamak and providing an upper limit on the amount of loose dust, the PFCs' surface morphology measurement could indirectly contribute to keep fusion operational limits and fusion device safety. Aiming at in situ dynamic monitoring PFCs' surface morphology evolution, a laboratory experimental platform DUT-SIEP (Dalian University of Technology-speckle interferometry experimental platform) based on the speckle interferometry technique has been constructed at Dalian University of Technology (DUT) in China. With directional specific designing and focusing on the real detection condition of EAST (Experimental Advanced Superconducting Tokamak), the DUT-SIEP could realize a variable measurement range, widely increased from 0.1 μm to 300 μm, with high spatial resolution (<1 mm) and ultra-high time resolution (<2 s for EAST measuring conditions). Three main components of the DUT-SIEP are all integrated and synchronized by a time schedule control and data acquisition terminal and coupled with a three-dimensional phase unwrapping algorithm, the surface morphology information of target samples can be obtained and reconstructed in real-time. A local surface morphology of the real divertor tiles adopted from EAST has been measured, and the feasibility and reliability of this new experimental platform have been demonstrated.
High-speed autofocusing of a cell using diffraction pattern
NASA Astrophysics Data System (ADS)
Oku, Hiromasa; Ishikawa, Masatoshi; Theodorus; Hashimoto, Koichi
2006-05-01
This paper proposes a new autofocusing method for observing cells under a transmission illumination. The focusing method uses a quick and simple focus estimation technique termed “depth from diffraction,” which is based on a diffraction pattern in a defocused image of a biological specimen. Since this method can estimate the focal position of the specimen from only a single defocused image, it can easily realize high-speed autofocusing. To demonstrate the method, it was applied to continuous focus tracking of a swimming paramecium, in combination with two-dimensional position tracking. Three-dimensional tracking of the paramecium for 70 s was successfully demonstrated.
Speckle interferometry of asteroids. I - 433 Eros
NASA Technical Reports Server (NTRS)
Drummond, J. D.; Cocke, W. J.; Hege, E. K.; Strittmatter, P. A.; Lambert, J. V.
1985-01-01
Analytical expressions are derived for the semimajor and semiminor axes and orientation angle of the ellipse projected by a triaxial asteroid, and the results are applied speckle-interferometry observations of the 433 Eros asteroid. The expressions were calculated as functions of the dimensions and pole of the body and of the asterocentric position of the earth and the sun. On the basis of the analytical expressions, the dimensions of 433 Eros are obtained. The light curve from December 18, 1981 is compared to the dimensions to obtain a geometric albedo of 0.156 (+ or - 0.010). A series of two-dimensional power spectra and autocorrelation functions for 433 Eros show that it is spinning in space.
George-Téllez, R; Segura-Valdez, M L; González-Santos, L; Jiménez-García, L F
2002-05-01
In the mammalian cell nucleus, splicing factors are distributed in nuclear domains known as speckles or splicing factor compartments (SFCs). In cultured cells, these domains are dynamic and reflect transcriptional and splicing activities. We used immunofluorescence and confocal microscopy to monitor whether splicing factors in differentiated cells display similar features. Speckled patterns are observed in rat hepatocytes, beta-cells, bronchial and intestine epithelia and also in three cell types of the uterus. Moreover, the number, distribution and sizes of the speckles vary among them. In addition, we studied variations in the circular form (shape) of speckles in uterine cells that are transcriptionally modified by a hormone action. During proestrus of the estral cycle, speckles are irregular in shape while in diestrus I they are circular. Experimentally, in castrated rats luminal epithelial cells show a pattern where speckles are dramatically rounded, but they recover their irregular shape rapidly after an injection of estradiol. The same results were observed in muscle and gland epithelial cells of the uterus. We concluded that different speckled patterns are present in various cells types in differentiated tissues and that these patterns change in the uterus depending upon the presence or absence of hormones such as estradiol.
Precision Positional Data of General Aviation Air Traffic in Terminal Air Space
NASA Technical Reports Server (NTRS)
Melson, W. E., Jr.; Parker, L. C.; Northam, A. M.; Singh, R. P.
1978-01-01
Three dimensional radar tracks of general aviation air traffic at three uncontrolled airports are considered. Contained are data which describe the position-time histories, other derived parameters, and reference data for the approximately 1200 tracks. All information was correlated such that the date, time, flight number, and runway number match the pattern type, aircraft type, wind, visibility, and cloud conditions.
Simultaneous total cavopulmonary connection and cardiac re-synchronisation therapy.
Nakanishi, Keisuke; Kawasaki, Shiori; Amano, Atsushi
2017-08-01
We report the simultaneous use of cardiac re-synchronisation therapy and total cavopulmonary connection in a patient with dyssynchrony, wide QRS, and cardiac failure. To our knowledge, this simultaneous approach has not been reported previously. On follow-up, we noted that QRS width and brain natriuretic peptide levels improved. In addition, speckle tracking revealed improved synchronisation of ventricular wall motion.
Multiple rotation assessment through isothetic fringes in speckle photography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Angel, Luciano; Tebaldi, Myrian; Bolognini, Nestor
2007-05-10
The use of different pupils for storing each speckled image in speckle photography is employed to determine multiple in-plane rotations. The method consists of recording a four-exposure specklegram where the rotations are done between exposures. This specklegram is then optically processed in a whole field approach rendering isothetic fringes, which give detailed information about the multiple rotations. It is experimentally demonstrated that the proposed arrangement permits the depiction of six isothetics in order to measure either six different angles or three nonparallel components for two local general in-plane displacements.
Magneto-optical nanoparticles for cyclic magnetomotive photoacoustic imaging
NASA Astrophysics Data System (ADS)
Arnal, Bastien; Yoon, Soon Joon; Li, Junwei; Gao, Xiaohu; O'Donnell, Matthew
2018-05-01
Photoacoustic imaging is a highly promising tool to visualize molecular events with deep tissue penetration. Like most other modalities, however, image contrast under in vivo conditions is far from optimal due to background signals from tissue. Using iron oxide-gold core-shell nanoparticles, we previously demonstrated that magnetomotive photoacoustic (mmPA) imaging can dramatically reduce the influence of background signals and produce high-contrast molecular images. Here we report two significant advances toward clinical translation of this technology. First, we introduce a new class of compact, uniform, magneto-optically coupled core-shell nanoparticle, prepared through localized copolymerization of polypyrrole (PPy) on an iron oxide nanoparticle surface. The resulting iron oxide-PPy nanoparticles solve the photo-instability and small-scale synthesis problems previously encountered by the gold coating approach, and extend the large optical absorption coefficient of the particles beyond 1000 nm in wavelength. In parallel, we have developed a new generation of mmPA imaging featuring cyclic magnetic motion and ultrasound speckle tracking, with an image capture frame rate several hundred times faster than the photoacoustic speckle tracking method demonstrated previously. These advances enable robust artifact elimination caused by physiologic motion and first application of the mmPA technology in vivo for sensitive tumor imaging.
Peolsson, Anneli; Peolsson, Michael
2014-05-01
This study aimed to describe and compare the longitudinal mechanical activity, deformation, and deformation rate of the different layers of dorsal and ventral neck muscles in healthy volunteers during head lifts against gravity. The cross-sectional study included 19 healthy volunteers (mean age, 28 years; SD, 7 years). Ultrasound with speckle-tracking analysis was used to investigate longitudinal mechanical activation, deformation, and deformation rate of dorsal and ventral neck muscles in real time during a head lift. Significance levels were set as P = .025 or P = .0125, depending on the number of comparisons. The dorsal neck muscles did not significantly differ in deformation (P > .04); however, the multifidus had a higher deformation rate than all other dorsal muscles (P < .003). The sternocleidomastoid had significantly higher deformation than the longus capitis (P = .005) and colli (P = .001) but a lower deformation rate than the longus colli (P = .02). The sternocleidomastoid deformed more than the deeper muscles, but it did significantly slower than the longus colli. Among the dorsal muscles, the deepest (the multifidus) had the highest deformation rate. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.
Gan, Yu; Fleming, Christine P.
2013-01-01
Abnormal changes in orientation of myofibers are associated with various cardiac diseases such as arrhythmia, irregular contraction, and cardiomyopathy. To extract fiber information, we present a method of quantifying fiber orientation and reconstructing three-dimensional tractography of myofibers using optical coherence tomography (OCT). A gradient based algorithm was developed to quantify fiber orientation in three dimensions and particle filtering technique was employed to track myofibers. Prior to image processing, three-dimensional image data set were acquired from all cardiac chambers and ventricular septum of swine hearts using OCT system without optical clearing. The algorithm was validated through rotation test and comparison with manual measurements. The experimental results demonstrate that we are able to visualize three-dimensional fiber tractography in myocardium tissues. PMID:24156071
NASA Astrophysics Data System (ADS)
Liu, Pengfei; Zhai, Wanming; Wang, Kaiyun
2016-11-01
For the long heavy-haul train, the basic principles of the inter-vehicle interaction and train-track dynamic interaction are analysed firstly. Based on the theories of train longitudinal dynamics and vehicle-track coupled dynamics, a three-dimensional (3-D) dynamic model of the heavy-haul train-track coupled system is established through a modularised method. Specifically, this model includes the subsystems such as the train control, the vehicle, the wheel-rail relation and the line geometries. And for the calculation of the wheel-rail interaction force under the driving or braking conditions, the large creep phenomenon that may occur within the wheel-rail contact patch is considered. For the coupler and draft gear system, the coupler forces in three directions and the coupler lateral tilt angles in curves are calculated. Then, according to the characteristics of the long heavy-haul train, an efficient solving method is developed to improve the computational efficiency for such a large system. Some basic principles which should be followed in order to meet the requirement of calculation accuracy are determined. Finally, the 3-D train-track coupled model is verified by comparing the calculated results with the running test results. It is indicated that the proposed dynamic model could simulate the dynamic performance of the heavy-haul train well.
Stat-tracks and mediotypes: powerful tools for modern ichnology based on 3D models
Bennett, Matthew R.; Marty, Daniel; Budka, Marcin; Reynolds, Sally C.; Bakirov, Rashid
2018-01-01
Vertebrate tracks are subject to a wide distribution of morphological types. A single trackmaker may be associated with a range of tracks reflecting individual pedal anatomy and behavioural kinematics mediated through substrate properties which may vary both in space and time. Accordingly, the same trackmaker can leave substantially different morphotypes something which must be considered in creating ichnotaxa. In modern practice this is often captured by the collection of a series of 3D track models. We introduce two concepts to help integrate these 3D models into ichnological analysis procedures. The mediotype is based on the idea of using statistically-generated three-dimensional track models (median or mean) of the type specimens to create a composite track to support formal recognition of a ichno type. A representative track (mean and/or median) is created from a set of individual reference tracks or from multiple examples from one or more trackways. In contrast, stat-tracks refer to other digitally generated tracks which may explore variance. For example, they are useful in: understanding the preservation variability of a given track sample; identifying characteristics or unusual track features; or simply as a quantitative comparison tool. Both concepts assist in making ichnotaxonomical interpretations and we argue that they should become part of the standard procedure when instituting new ichnotaxa. As three-dimensional models start to become a standard in publications on vertebrate ichnology, the mediotype and stat-track concepts have the potential to help guiding a revolution in the study of vertebrate ichnology and ichnotaxonomy. PMID:29340246
Three-dimensional microbubble streaming flows
NASA Astrophysics Data System (ADS)
Rallabandi, Bhargav; Marin, Alvaro; Rossi, Massimiliano; Kaehler, Christian; Hilgenfeldt, Sascha
2014-11-01
Streaming due to acoustically excited bubbles has been used successfully for applications such as size-sorting, trapping and focusing of particles, as well as fluid mixing. Many of these applications involve the precise control of particle trajectories, typically achieved using cylindrical bubbles, which establish planar flows. Using astigmatic particle tracking velocimetry (APTV), we show that, while this two-dimensional picture is a useful description of the flow over short times, a systematic three-dimensional flow structure is evident over long time scales. We demonstrate that this long-time three-dimensional fluid motion can be understood through asymptotic theory, superimposing secondary axial flows (induced by boundary conditions at the device walls) onto the two-dimensional description. This leads to a general framework that describes three-dimensional flows in confined microstreaming systems, guiding the design of applications that profit from minimizing or maximizing these effects.
Beam tracking phase tomography with laboratory sources
NASA Astrophysics Data System (ADS)
Vittoria, F. A.; Endrizzi, M.; Kallon, G. K. N.; Hagen, C. K.; Diemoz, P. C.; Zamir, A.; Olivo, A.
2018-04-01
An X-ray phase-contrast laboratory system is presented, based on the beam-tracking method. Beam-tracking relies on creating micro-beamlets of radiation by placing a structured mask before the sample, and analysing them by using a detector with sufficient resolution. The system is used in tomographic configuration to measure the three dimensional distribution of the linear attenuation coefficient, difference from unity of the real part of the refractive index, and of the local scattering power of specimens. The complementarity of the three signals is investigated, together with their potential use for material discrimination.
Imaging Gravity Waves in Lower Stratospheric AMSU-A Radiances. Part 1: Simple Forward Model
2006-08-14
brightening” of microwave radiances acquired from purely vertical background temperature profiles by cross- track scanners. Waves propagating along track...three-dimensional wave fields. For example, some limb sensors return high- resolution vertical temperature profiles with wave oscilla- tions...provide only ver- tical profiles of wave oscillations, similar to radiosonde and rocketsonde data. Similarly, limb-tracking measurements from the
Assessment of corneal properties based on statistical modeling of OCT speckle.
Jesus, Danilo A; Iskander, D Robert
2017-01-01
A new approach to assess the properties of the corneal micro-structure in vivo based on the statistical modeling of speckle obtained from Optical Coherence Tomography (OCT) is presented. A number of statistical models were proposed to fit the corneal speckle data obtained from OCT raw image. Short-term changes in corneal properties were studied by inducing corneal swelling whereas age-related changes were observed analyzing data of sixty-five subjects aged between twenty-four and seventy-three years. Generalized Gamma distribution has shown to be the best model, in terms of the Akaike's Information Criterion, to fit the OCT corneal speckle. Its parameters have shown statistically significant differences (Kruskal-Wallis, p < 0.001) for short and age-related corneal changes. In addition, it was observed that age-related changes influence the corneal biomechanical behaviour when corneal swelling is induced. This study shows that Generalized Gamma distribution can be utilized to modeling corneal speckle in OCT in vivo providing complementary quantified information where micro-structure of corneal tissue is of essence.
Fully three-dimensional analysis of high-speed train-track-soil-structure dynamic interaction
NASA Astrophysics Data System (ADS)
Galvín, P.; Romero, A.; Domínguez, J.
2010-11-01
In this paper, a general and fully three dimensional multi-body-finite element-boundary element model, formulated in the time domain to predict vibrations due to train passage at the vehicle, the track and the free field, is presented. The vehicle is modelled as a multi-body system and, therefore, the quasi-static and the dynamic excitation mechanisms due to train passage can be considered. The track is modelled using finite elements. The soil is considered as a homogeneous half-space by the boundary element method. This methodology could be used to take into account local soil discontinuities, underground constructions such as underpasses, and coupling with nearby structures that break the uniformity of the geometry along the track line. The nonlinear behaviour of the structures could be also considered. In the present paper, in order to test the model, vibrations induced by high-speed train passage are evaluated for a ballasted track. The quasi-static and dynamic load components are studied and the influence of the suspended mass on the vertical loads is analyzed. The numerical model is validated by comparison with experimental records from two HST lines. Finally, the dynamic behaviour of a transition zone between a ballast track and a slab track is analyzed and the obtained results from the proposed model are compared with those obtained from a model with invariant geometry with respect to the track direction.
NASA Astrophysics Data System (ADS)
Lien, Chi-Hsiang; Lin, Chun-Yu; Chen, Shean-Jen; Chien, Fan-Ching
2017-02-01
A three-dimensional (3D) single fluorescent particle tracking strategy based on temporal focusing multiphoton excitation microscopy (TFMPEM) combined with astigmatism imaging is proposed for delivering nanoscale-level axial information that reveals 3D trajectories of single fluorospheres in the axially-resolved multiphoton excitation volume without z-axis scanning. It provides the dynamical ability by measuring the diffusion coefficient of fluorospheres in glycerol solutions with a position standard deviation of 14 nm and 21 nm in the lateral and axial direction and a frame rate of 100 Hz. Moreover, the optical trapping force based on the TFMPEM is minimized to avoid the interference in the tracing measurements compared to that in the spatial focusing MPE approaches. Therefore, we presented a three dimensional single particle tracking strategy to overcome the limitation of the time resolution of the multiphoton imaging using fast frame rate of TFMPEM, and provide three dimensional locations of multiple particles using an astigmatism method.
The development of laser speckle velocimetry for the study of vortical flows
NASA Technical Reports Server (NTRS)
Krothapalli, A.
1991-01-01
A new experimental technique commonly known as PIDV (particle image displacement velocity) was developed to measure an instantaneous two dimensional velocity fluid in a selected plane of the flow field. This technique was successfully applied to the study of several problems: (1) unsteady flows with large scale vortical structures; (2) the instantaneous two dimensional flow in the transition region of a rectangular air jet; and (3) the instantaneous flow over a circular bump in a transonic flow. In several other experiments PIDV is routinely used as a non-intrusive measurement technique to obtain instantaneous two dimensional velocity fields.
NASA Astrophysics Data System (ADS)
Edwards, Philip J.; Hobson, Peter R.; Rodgers, G. J.
2000-08-01
In-line particle holography is subject to image deterioration due to intrinsic speckle noise. The resulting reduction in the signal to noise ratio (SNR) of the replayed image can become critical for applications such as holographic particle velocimetry (HPV) and 3D visualisation of marine plankton. Work has been done to extend the mono-disperse model relevant to HPV to include poly-disperse particle fields appropriate for the visualisation of marine plankton. Continuous and discrete particle fields are both considered. It is found that random walk statistics still apply for the poly-disperse case. The speckle field is simply the summation of the individual speckle patters due to each scatter size. Therefor the characteristic speckle parameter (which encompasses particle diameter, concentration and sample depth) is alos just the summation of the individual speckle parameters. This reduces the SNR calculation to the same form as for the mono-disperse case. For the continuous situation three distributions, power, exponential and Gaussian are discussed with the resulting SNR calcuated. The work presented here was performed as part of the Holomar project to produce a working underwater holographic camera for recording plankton.
A hybrid algorithm for speckle noise reduction of ultrasound images.
Singh, Karamjeet; Ranade, Sukhjeet Kaur; Singh, Chandan
2017-09-01
Medical images are contaminated by multiplicative speckle noise which significantly reduce the contrast of ultrasound images and creates a negative effect on various image interpretation tasks. In this paper, we proposed a hybrid denoising approach which collaborate the both local and nonlocal information in an efficient manner. The proposed hybrid algorithm consist of three stages in which at first stage the use of local statistics in the form of guided filter is used to reduce the effect of speckle noise initially. Then, an improved speckle reducing bilateral filter (SRBF) is developed to further reduce the speckle noise from the medical images. Finally, to reconstruct the diffused edges we have used the efficient post-processing technique which jointly considered the advantages of both bilateral and nonlocal mean (NLM) filter for the attenuation of speckle noise efficiently. The performance of proposed hybrid algorithm is evaluated on synthetic, simulated and real ultrasound images. The experiments conducted on various test images demonstrate that our proposed hybrid approach outperforms the various traditional speckle reduction approaches included recently proposed NLM and optimized Bayesian-based NLM. The results of various quantitative, qualitative measures and by visual inspection of denoise synthetic and real ultrasound images demonstrate that the proposed hybrid algorithm have strong denoising capability and able to preserve the fine image details such as edge of a lesion better than previously developed methods for speckle noise reduction. The denoising and edge preserving capability of hybrid algorithm is far better than existing traditional and recently proposed speckle reduction (SR) filters. The success of proposed algorithm would help in building the lay foundation for inventing the hybrid algorithms for denoising of ultrasound images. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
McDowell, Mark (Inventor); Glasgow, Thomas K. (Inventor)
1999-01-01
A system and a method for measuring three-dimensional velocities at a plurality of points in a fluid employing at least two cameras positioned approximately perpendicular to one another. The cameras are calibrated to accurately represent image coordinates in world coordinate system. The two-dimensional views of the cameras are recorded for image processing and centroid coordinate determination. Any overlapping particle clusters are decomposed into constituent centroids. The tracer particles are tracked on a two-dimensional basis and then stereo matched to obtain three-dimensional locations of the particles as a function of time so that velocities can be measured therefrom The stereo imaging velocimetry technique of the present invention provides a full-field. quantitative, three-dimensional map of any optically transparent fluid which is seeded with tracer particles.
The influence of track modelling options on the simulation of rail vehicle dynamics
NASA Astrophysics Data System (ADS)
Di Gialleonardo, Egidio; Braghin, Francesco; Bruni, Stefano
2012-09-01
This paper investigates the effect of different models for track flexibility on the simulation of railway vehicle running dynamics on tangent and curved track. To this end, a multi-body model of the rail vehicle is defined including track flexibility effects on three levels of detail: a perfectly rigid pair of rails, a sectional track model and a three-dimensional finite element track model. The influence of the track model on the calculation of the nonlinear critical speed is pointed out and it is shown that neglecting the effect of track flexibility results in an overestimation of the critical speed by more than 10%. Vehicle response to stochastic excitation from track irregularity is also investigated, analysing the effect of track flexibility models on the vertical and lateral wheel-rail contact forces. Finally, the effect of the track model on the calculation of dynamic forces produced by wheel out-of-roundness is analysed, showing that peak dynamic loads are very sensitive to the track model used in the simulation.
Ding, Yu; Li, Chunqiang
2016-01-01
Nanoscale particle tracking in three dimensions is crucial to directly observe dynamics of molecules and nanoparticles in living cells. Here we present a three-dimensional particle tracking method based on temporally focused two-photon excitation. Multiple particles are imaged at 30 frames/s in volume up to 180 × 180 × 100 µm3. The spatial localization precision can reach 50 nm. We demonstrate its capability of tracking fast swimming microbes at speed of ~200 µm/s. Two-photon dual-color tracking is achieved by simultaneously exciting two kinds of fluorescent beads at 800 nm to demonstrate its potential in molecular interaction studies. Our method provides a simple wide-field fluorescence imaging approach for deep multiple-particle tracking. PMID:27867724
Three-dimensional magnetic bubble memory system
NASA Technical Reports Server (NTRS)
Stadler, Henry L. (Inventor); Katti, Romney R. (Inventor); Wu, Jiin-Chuan (Inventor)
1994-01-01
A compact memory uses magnetic bubble technology for providing data storage. A three-dimensional arrangement, in the form of stacks of magnetic bubble layers, is used to achieve high volumetric storage density. Output tracks are used within each layer to allow data to be accessed uniquely and unambiguously. Storage can be achieved using either current access or field access magnetic bubble technology. Optical sensing via the Faraday effect is used to detect data. Optical sensing facilitates the accessing of data from within the three-dimensional package and lends itself to parallel operation for supporting high data rates and vector and parallel processing.
Development and testing of 2-dimensional photon counter
NASA Technical Reports Server (NTRS)
1981-01-01
The development of a commercially available two dimensional photon counter into an operational system for speckle imaging of astronomical objects is described. The system includes digital recording for field observations. The counter has a bialkali photocathode with a field size of 18 by 18 mm over which it resolves about 100 by 100 pixels. The system records photon positions as 16 bit words at rates up to 14,400 per second. Field tests at observatories verifying the operation of the system are described.
Learnable despeckling framework for optical coherence tomography images
NASA Astrophysics Data System (ADS)
Adabi, Saba; Rashedi, Elaheh; Clayton, Anne; Mohebbi-Kalkhoran, Hamed; Chen, Xue-wen; Conforto, Silvia; Nasiriavanaki, Mohammadreza
2018-01-01
Optical coherence tomography (OCT) is a prevalent, interferometric, high-resolution imaging method with broad biomedical applications. Nonetheless, OCT images suffer from an artifact called speckle, which degrades the image quality. Digital filters offer an opportunity for image improvement in clinical OCT devices, where hardware modification to enhance images is expensive. To reduce speckle, a wide variety of digital filters have been proposed; selecting the most appropriate filter for an OCT image/image set is a challenging decision, especially in dermatology applications of OCT where a different variety of tissues are imaged. To tackle this challenge, we propose an expandable learnable despeckling framework, we call LDF. LDF decides which speckle reduction algorithm is most effective on a given image by learning a figure of merit (FOM) as a single quantitative image assessment measure. LDF is learnable, which means when implemented on an OCT machine, each given image/image set is retrained and its performance is improved. Also, LDF is expandable, meaning that any despeckling algorithm can easily be added to it. The architecture of LDF includes two main parts: (i) an autoencoder neural network and (ii) filter classifier. The autoencoder learns the FOM based on several quality assessment measures obtained from the OCT image including signal-to-noise ratio, contrast-to-noise ratio, equivalent number of looks, edge preservation index, and mean structural similarity index. Subsequently, the filter classifier identifies the most efficient filter from the following categories: (a) sliding window filters including median, mean, and symmetric nearest neighborhood, (b) adaptive statistical-based filters including Wiener, homomorphic Lee, and Kuwahara, and (c) edge preserved patch or pixel correlation-based filters including nonlocal mean, total variation, and block matching three-dimensional filtering.
Skaarup, Kristoffer Grundtvig; Christensen, Hanne; Høst, Nis; Mahmoud, Masti Mahdy; Ovesen, Christian; Olsen, Flemming Javier; Jensen, Jan Skov; Biering-Sørensen, Tor
2017-12-01
Asymptomatic paroxysmal atrial fibrillation (PAF) is often assumed to be the cause of cryptogenic ischemic strokes (IS) and transient ischemic attacks (TIA). We examined the usefulness of measures obtained by 2D speckle tracking echocardiography and novel left atrial measurements, in the diagnosis of PAF in patients with IS and TIA. We retrospectively included 205 patients who after acute IS or TIA underwent an echocardiogram in sinus rhythm. Patients were designated as PAF-patients if they had one or more reported incidents of AF before or after their echocardiographic examination. None of the conventional echocardiographic parameters were significantly associated with PAF. Of the speckle tracking measurements, only early diastolic strain rate (0.7±0.2 s -1 vs. 0.8±0.3 s -1 , p = 0.048) and global longitudinal displacement (GLD) (3.15 ± 1.40 mm vs. 3.87 ± 1.56 mm, p = 0.007) proved significantly different. Of the left atrial parameters both minimal and maximal left atrium volume divided by left ventricular length (min LAV/LVL and max LAV/LVL, respectively) were significantly impaired (min LAV/LVL: 3.7 ± 2.1 cm 2 vs. 2.8 ± 1.11 cm 2 , p = 0.012; max LAV/LVL: 6.6 ± 3.1 cm 2 vs. 5.6 ± 1.7 cm 2 , p = 0.012). GLD, min max LAV/LVL proved significant after adjustment for age, gender, CHA 2 DS 2 -VASc and NIHSS. By combining information regarding age, GLD, min and max LAV/LVL the diagnostic accuracy of PAF improved, resulting in a significantly increased area under the curve (p = 0.037). In patients with IS and TIA GLD, min and max LAV/LVL were independently associated with the presence of PAF.
Lemarié, Jérémie; Huttin, Olivier; Girerd, Nicolas; Mandry, Damien; Juillière, Yves; Moulin, Frédéric; Lemoine, Simon; Beaumont, Marine; Marie, Pierre-Yves; Selton-Suty, Christine
2015-07-01
Right ventricular (RV) dysfunction after acute myocardial infarction (AMI) is frequent and associated with poor prognosis. The complex anatomy of the right ventricle makes its echocardiographic assessment challenging. Quantification of RV deformation by speckle-tracking echocardiography is a widely available and reproducible technique that readily provides an integrated analysis of all segments of the right ventricle. The aim of this study was to investigate the accuracy of conventional echocardiographic parameters and speckle-tracking echocardiographic strain parameters in assessing RV function after AMI, in comparison with cardiac magnetic resonance imaging (CMR). A total of 135 patients admitted for AMI (73 anterior, 62 inferior) were prospectively studied. Right ventricular function was assessed by echocardiography and CMR within 2 to 4 days of hospital admission. Right ventricular dysfunction was defined as CMR RV ejection fraction < 50%. Right ventricular global peak longitudinal systolic strain (GLPSS) was calculated by averaging the strain values of the septal, lateral, and inferior walls. Right ventricular dysfunction was documented in 20 patients. Right ventricular GLPSS was the best echographic correlate of CMR RV ejection fraction (r = -0.459, P < .0001) and possessed good diagnostic value for RV dysfunction (area under the receiver operating characteristic curve [AUROC], 0.724; 95% CI, 0.590-0.857), which was comparable with that of RV fractional area change (AUROC, 0.756; 95% CI, 0.647-0.866). In patients with inferior myocardial infarctions, the AUROCs for RV GLPSS (0.822) and inferolateral strain (0.877) were greater than that observed for RV fractional area change (0.760) Other conventional echocardiographic parameters performed poorly (all AUROCs < 0.700). After AMI, RV GLPSS is the best correlate of CMR RV ejection fraction. In patients with inferior AMIs, RV GLPSS displays even higher diagnostic value than conventional echocardiographic parameters. Copyright © 2015 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Spalla, I; Locatelli, C; Zanaboni, A M; Brambilla, P; Bussadori, C
2016-05-01
Patent ductus arteriosus (PDA) is 1 of the most common congenital heart defects in dogs and percutaneous closure is effective in achieving ductal closure; PDA closure is associated with abrupt hemodynamic changes. A marked decrease in standard parameters of systolic function as assessed by M- or B-mode echocardiography after PDA closure was identified in previous studies. Speckle tracking echocardiography can provide further insight into the effect of PDA closure on cardiac mechanics in dogs affected by PDA. Twenty-five client-owned dogs with PDA. Prospective study. Dogs were recruited over a 2-year period. Complete echocardiographic evaluation was performed before and 24 hours after PDA closure, including standard (end-diastolic volumes indexed to body surface area in B- and M-mode [EDVIB /M ], end-systolic volumes indexed to body surface area in B- and M-mode [ESVIB /M ], allometric scaling in diastole [AlloD] and systole [AlloS], pulmonary flow to systemic flow [Qs/Qp], ejection fraction [EF], and fractional shortening [FS]), and advanced speckle-tracking echocardiography (STE): global longitudinal, radial, circumferential and transverse strain (S), and strain rate (SR). Patent ductus arteriosus closure was associated with statistically significant decreases in EDVIM /B and ESVIM /B , AlloD and AlloS, SI, EF, and FS. A statistically significant decrease in the absolute values of radial, transverse, and circumferential S and SR was observed, whereas longitudinal S and SR did not change significantly. Patent ductus arteriosus closure by percutaneous approach is associated with marked decreases of conventional echocardiographic parameters as a result of the changes in loading conditions, but no evidence of systolic dysfunction was identified by means of STE, as none of the S and SR values were below reference ranges. In the short term, contractility is enhanced in the long axis (long S/SR values were not statistically different before and after closure) and decreases to normal values in short axis (circumferential, radial, and transversal S/SR decreased to normal reference range). Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Gijsbertse, Kaj; Goselink, Rianne; Lassche, Saskia; Nillesen, Maartje; Sprengers, André; Verdonschot, Nico; van Alfen, Nens; de Korte, Chris
2017-11-01
A need exists for biomarkers to diagnose, quantify and longitudinally follow facioscapulohumeral muscular dystrophy (FSHD) and many other neuromuscular disorders. Furthermore, the pathophysiological mechanisms leading to muscle weakness in most neuromuscular disorders are not completely understood. Dynamic ultrasound imaging (B-mode image sequences) in combination with speckle tracking is an easy, applicable and patient-friendly imaging tool to visualize and quantify muscle deformation. This dynamic information provides insight in the pathophysiological mechanisms and may help to distinguish the various stages of diseased muscle in FSHD. In this proof-of-principle study, we applied a speckle tracking technique to 2-D ultrasound image sequences to quantify the deformation of the tibialis anterior muscle in patients with FSHD and in healthy controls. The resulting deformation patterns were compared with muscle ultrasound echo intensity analysis (a measure of fat infiltration and dystrophy) and clinical outcome measures. Of the four FSHD patients, two patients had severe peroneal weakness and two patients had mild peroneal weakness on clinical examination. We found a markedly varied muscle deformation pattern between these groups: patients with severe peroneal weakness showed a different motion pattern of the tibialis anterior, with overall less displacement of the central tendon region, while healthy patients showed a non-uniform displacement pattern, with the central aponeurosis showing the largest displacement. Hence, dynamic muscle ultrasound of the tibialis anterior muscle in patients with FSHD revealed a distinctively different tissue deformation pattern among persons with and without tibialis anterior weakness. These findings could clarify the understanding of the pathophysiology of muscle weakness in FSHD patients. In addition, the change in muscle deformation shows good correlation with clinical measures and quantitative muscle ultrasound measurements. In conclusion, dynamic ultrasound in combination with speckle tracking allows the study of the effects of muscle pathology in relation to strength, force transmission and movement generation. Although further research is required, this technique can develop into a biomarker to quantify muscle disease severity. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Alam, Mahboob; Zhang, Lily; Stampehl, Mark; Lakkis, Nasser; Dokainish, Hisham
2013-07-15
The acute impact of hypertensive crisis, and changes after treatment, on left ventricular (LV) systolic and diastolic function using comprehensive echocardiography, including speckle tracking, has not been well characterized. Thirty consecutive patients admitted to the hospital from the emergency room with hypertensive crisis underwent Doppler echocardiography at baseline and after blood pressure optimization. The mean age of the patients was 54 ± 13 years, with 19 men (63%). The most common presenting symptoms included dyspnea (70%), chest pain (43%), and altered mental status (13%). Mean systolic and diastolic blood pressures at presentation were 198 ± 12 and 122 ± 12 mm Hg, decreasing to 143 ± 15 and 77 ± 12 mm Hg (p <0.001 for both) after treatment. There was no significant change in LV ejection fraction between baseline and follow-up (48 ± 18% vs 46 ± 18%, p = 0.50); however, global longitudinal LV systolic strain (-10 ± 4% to -12 ± 4%, p = 0.01) and global systolic strain rate (-1.0 ± 0.4 vs -1.4 ± 0.6 s(-1), p = 0.01) significantly improved. Mean global early diastolic strain (-7.2 ± 4.0% to -9.4 ± 2.9%, p = 0.004) and early diastolic strain rate (0.3 ± 0.2 to 0.5 ± 0.4 s(-1), p = 0.05) also improved after treatment. On multivariate analysis, the independent predictors of LV longitudinal strain at follow-up were LV ejection fraction (p <0.001), heart rate (p = 0.005), systolic blood pressure (p = 0.04), and left atrial volume index (p = 0.05). In conclusion, as opposed to LV ejection fraction, LV systolic strain and strain rate were depressed during hypertensive crisis and significantly improved after medical treatment. LV diastolic function, assessed using conventional and speckle-tracking parameters, was also depressed and significantly improved after treatment. Copyright © 2013 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Makedonska, Nataliia; Painter, Scott L.; Bui, Quan M.
The discrete fracture network (DFN) model is a method to mimic discrete pathways for fluid flow through a fractured low-permeable rock mass, and may be combined with particle tracking simulations to address solute transport. However, experience has shown that it is challenging to obtain accurate transport results in three-dimensional DFNs because of the high computational burden and difficulty in constructing a high-quality unstructured computational mesh on simulated fractures. We present a new particle tracking capability, which is adapted to control volume (Voronoi polygons) flow solutions on unstructured grids (Delaunay triangulations) on three-dimensional DFNs. The locally mass-conserving finite-volume approach eliminates massmore » balance-related problems during particle tracking. The scalar fluxes calculated for each control volume face by the flow solver are used to reconstruct a Darcy velocity at each control volume centroid. The groundwater velocities can then be continuously interpolated to any point in the domain of interest. The control volumes at fracture intersections are split into four pieces, and the velocity is reconstructed independently on each piece, which results in multiple groundwater velocities at the intersection, one for each fracture on each side of the intersection line. This technique enables detailed particle transport representation through a complex DFN structure. Verified for small DFNs, the new simulation capability enables numerical experiments on advective transport in large DFNs to be performed. As a result, we demonstrate this particle transport approach on a DFN model using parameters similar to those of crystalline rock at a proposed geologic repository for spent nuclear fuel in Forsmark, Sweden.« less
Makedonska, Nataliia; Painter, Scott L.; Bui, Quan M.; ...
2015-09-16
The discrete fracture network (DFN) model is a method to mimic discrete pathways for fluid flow through a fractured low-permeable rock mass, and may be combined with particle tracking simulations to address solute transport. However, experience has shown that it is challenging to obtain accurate transport results in three-dimensional DFNs because of the high computational burden and difficulty in constructing a high-quality unstructured computational mesh on simulated fractures. We present a new particle tracking capability, which is adapted to control volume (Voronoi polygons) flow solutions on unstructured grids (Delaunay triangulations) on three-dimensional DFNs. The locally mass-conserving finite-volume approach eliminates massmore » balance-related problems during particle tracking. The scalar fluxes calculated for each control volume face by the flow solver are used to reconstruct a Darcy velocity at each control volume centroid. The groundwater velocities can then be continuously interpolated to any point in the domain of interest. The control volumes at fracture intersections are split into four pieces, and the velocity is reconstructed independently on each piece, which results in multiple groundwater velocities at the intersection, one for each fracture on each side of the intersection line. This technique enables detailed particle transport representation through a complex DFN structure. Verified for small DFNs, the new simulation capability enables numerical experiments on advective transport in large DFNs to be performed. As a result, we demonstrate this particle transport approach on a DFN model using parameters similar to those of crystalline rock at a proposed geologic repository for spent nuclear fuel in Forsmark, Sweden.« less
Single-camera three-dimensional tracking of natural particulate and zooplankton
NASA Astrophysics Data System (ADS)
Troutman, Valerie A.; Dabiri, John O.
2018-07-01
We develop and characterize an image processing algorithm to adapt single-camera defocusing digital particle image velocimetry (DDPIV) for three-dimensional (3D) particle tracking velocimetry (PTV) of natural particulates, such as those present in the ocean. The conventional DDPIV technique is extended to facilitate tracking of non-uniform, non-spherical particles within a volume depth an order of magnitude larger than current single-camera applications (i.e. 10 cm × 10 cm × 24 cm depth) by a dynamic template matching method. This 2D cross-correlation method does not rely on precise determination of the centroid of the tracked objects. To accommodate the broad range of particle number densities found in natural marine environments, the performance of the measurement technique at higher particle densities has been improved by utilizing the time-history of tracked objects to inform 3D reconstruction. The developed processing algorithms were analyzed using synthetically generated images of flow induced by Hill’s spherical vortex, and the capabilities of the measurement technique were demonstrated empirically through volumetric reconstructions of the 3D trajectories of particles and highly non-spherical, 5 mm zooplankton.
NASA Astrophysics Data System (ADS)
Mazzoleni, Paolo; Matta, Fabio; Zappa, Emanuele; Sutton, Michael A.; Cigada, Alfredo
2015-03-01
This paper discusses the effect of pre-processing image blurring on the uncertainty of two-dimensional digital image correlation (DIC) measurements for the specific case of numerically-designed speckle patterns having particles with well-defined and consistent shape, size and spacing. Such patterns are more suitable for large measurement surfaces on large-scale specimens than traditional spray-painted random patterns without well-defined particles. The methodology consists of numerical simulations where Gaussian digital filters with varying standard deviation are applied to a reference speckle pattern. To simplify the pattern application process for large areas and increase contrast to reduce measurement uncertainty, the speckle shape, mean size and on-center spacing were selected to be representative of numerically-designed patterns that can be applied on large surfaces through different techniques (e.g., spray-painting through stencils). Such 'designer patterns' are characterized by well-defined regions of non-zero frequency content and non-zero peaks, and are fundamentally different from typical spray-painted patterns whose frequency content exhibits near-zero peaks. The effect of blurring filters is examined for constant, linear, quadratic and cubic displacement fields. Maximum strains between ±250 and ±20,000 με are simulated, thus covering a relevant range for structural materials subjected to service and ultimate stresses. The robustness of the simulation procedure is verified experimentally using a physical speckle pattern subjected to constant displacements. The stability of the relation between standard deviation of the Gaussian filter and measurement uncertainty is assessed for linear displacement fields at varying image noise levels, subset size, and frequency content of the speckle pattern. It is shown that bias error as well as measurement uncertainty are minimized through Gaussian pre-filtering. This finding does not apply to typical spray-painted patterns without well-defined particles, for which image blurring is only beneficial in reducing bias errors.
A low cost real-time motion tracking approach using webcam technology.
Krishnan, Chandramouli; Washabaugh, Edward P; Seetharaman, Yogesh
2015-02-05
Physical therapy is an important component of gait recovery for individuals with locomotor dysfunction. There is a growing body of evidence that suggests that incorporating a motor learning task through visual feedback of movement trajectory is a useful approach to facilitate therapeutic outcomes. Visual feedback is typically provided by recording the subject's limb movement patterns using a three-dimensional motion capture system and displaying it in real-time using customized software. However, this approach can seldom be used in the clinic because of the technical expertise required to operate this device and the cost involved in procuring a three-dimensional motion capture system. In this paper, we describe a low cost two-dimensional real-time motion tracking approach using a simple webcam and an image processing algorithm in LabVIEW Vision Assistant. We also evaluated the accuracy of this approach using a high precision robotic device (Lokomat) across various walking speeds. Further, the reliability and feasibility of real-time motion-tracking were evaluated in healthy human participants. The results indicated that the measurements from the webcam tracking approach were reliable and accurate. Experiments on human subjects also showed that participants could utilize the real-time kinematic feedback generated from this device to successfully perform a motor learning task while walking on a treadmill. These findings suggest that the webcam motion tracking approach is a feasible low cost solution to perform real-time movement analysis and training. Copyright © 2014 Elsevier Ltd. All rights reserved.
A low cost real-time motion tracking approach using webcam technology
Krishnan, Chandramouli; Washabaugh, Edward P.; Seetharaman, Yogesh
2014-01-01
Physical therapy is an important component of gait recovery for individuals with locomotor dysfunction. There is a growing body of evidence that suggests that incorporating a motor learning task through visual feedback of movement trajectory is a useful approach to facilitate therapeutic outcomes. Visual feedback is typically provided by recording the subject’s limb movement patterns using a three-dimensional motion capture system and displaying it in real-time using customized software. However, this approach can seldom be used in the clinic because of the technical expertise required to operate this device and the cost involved in procuring a three-dimensional motion capture system. In this paper, we describe a low cost two-dimensional real-time motion tracking approach using a simple webcam and an image processing algorithm in LabVIEW Vision Assistant. We also evaluated the accuracy of this approach using a high precision robotic device (Lokomat) across various walking speeds. Further, the reliability and feasibility of real-time motion-tracking were evaluated in healthy human participants. The results indicated that the measurements from the webcam tracking approach were reliable and accurate. Experiments on human subjects also showed that participants could utilize the real-time kinematic feedback generated from this device to successfully perform a motor learning task while walking on a treadmill. These findings suggest that the webcam motion tracking approach is a feasible low cost solution to perform real-time movement analysis and training. PMID:25555306
Langford, Seth T.; Wiggins, Cody S.; Santos, Roque; ...
2017-07-06
A method for Positron Emission Particle Tracking (PEPT) based on optical feature point identification techniques is demonstrated for use in low activity tracking experiments. Furthermore, a population of yeast cells of approximately 125,000 members is activated to roughly 55 Bq/cell by 18F uptake. An in vitro particle tracking experiment is performed with nearly 20 of these cells after decay to 32 Bq/cell. These cells are successfully identified and tracked simultaneously in this experiment. Our work extends the applicability of PEPT as a cell tracking method by allowing a number of cells to be tracked together, and demonstrating tracking for verymore » low activity tracers.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Langford, Seth T.; Wiggins, Cody S.; Santos, Roque
A method for Positron Emission Particle Tracking (PEPT) based on optical feature point identification techniques is demonstrated for use in low activity tracking experiments. Furthermore, a population of yeast cells of approximately 125,000 members is activated to roughly 55 Bq/cell by 18F uptake. An in vitro particle tracking experiment is performed with nearly 20 of these cells after decay to 32 Bq/cell. These cells are successfully identified and tracked simultaneously in this experiment. Our work extends the applicability of PEPT as a cell tracking method by allowing a number of cells to be tracked together, and demonstrating tracking for verymore » low activity tracers.« less
Tracking a Head-Mounted Display in a Room-Sized Environment with Head-Mounted Cameras
1990-04-01
poor resolution and a very limited working volume [Wan90]. 4 OPTOTRAK [Nor88] uses one camera with two dual-axis CCD infrared position sensors. Each...Nor88] Northern Digital. Trade literature on Optotrak - Northern Digital’s Three Dimensional Optical Motion Tracking and Analysis System. Northern Digital
Interjoint coordination of the lower extremities in short-track speed skating.
Khuyagbaatar, Batbayar; Purevsuren, Tserenchimed; Park, Won Man; Kim, Kyungsoo; Kim, Yoon Hyuk
2017-10-01
In short-track speed skating, the three-dimensional kinematics of the lower extremities during the whole skating cycle have not been studied. Kinematic parameters of the lower extremities during skating are presented as joint angles versus time. However, the angle-time presentation is not sufficient to describe the relationship between multi-joint movement patterns. Thus, angle-angle presentations were developed and used to describe interjoint coordination in sport activities. In this study, 15 professional male skaters' full body motion data were recorded using a wearable motion capture system during short-track speed skating. We investigated the three-dimensional kinematics of the lower extremities and then established the interjoint coordination between hip-knee and knee-ankle for both legs during the whole skating cycle. The results demonstrate the relationship between multi-joint movements during different phases of short-track speed skating. This study provides fundamentals of the movement mechanism of the lower extremities that can be integrated with physiotherapy to improve skating posture and prevent injuries from repetitive stress since physiological characteristics play an important role in skating performance.
Gomes, Victor Augusto M; Alves, Gabriel F; Hadlich, Marcelo; Azevedo, Clerio F; Pereira, Iane M; Santos, Carla Renata F; Brasil, Pedro Emmanuel A A; Sangenis, Luiz Henrique C; Cunha, Ademir B; Xavier, Sergio S; Saraiva, Roberto M
2016-07-01
Chagas heart disease has a high socioeconomic burden, and any strategy to detect early myocardial damage is welcome. Speckle-tracking echocardiography assesses global and segmental left ventricular (LV) systolic function, yielding values of two-dimensional strain (ε). The aim of this study was to determine if patients with chronic Chagas disease and normal LV ejection fractions present abnormalities in global and segmental LV ε. In this prospective study, patients with Chagas disease with no evidence of cardiac involvement (group I; n = 83) or at stage A of the cardiac form (i.e., with changes limited to the electrocardiogram) (group A; n = 42) and 43 control subjects (group C) underwent evaluation of global and segmental LV ε by speckle-tracking echocardiography. A subset of randomly selected patients in group A underwent cardiac magnetic resonance imaging and repeated echocardiography 3.5 ± 0.8 years after the first evaluation. Mean age, chamber dimensions, and LV ejection fraction were similar among the groups. Global longitudinal (group C, -19 ± 2%; group I, -19 ± 2%; group A, -19 ± 2%), circumferential (group C, -19 ± 3%; group I, -20 ± 3%; group A, -19 ± 3%), and radial (group C, 46 ± 10%; group I, 45 ± 13%; group A, 42 ± 14%) LV ε were similar among the groups. Segmental longitudinal, circumferential, and radial LV ε were similar across the studied groups. Seven of 14 patients had areas of fibrosis on cardiac magnetic resonance imaging. Patients with fibrosis had lower global longitudinal (-15 ± 2% vs -18 ± 2%, P = .004), circumferential (-14 ± 2% vs -19 ± 2%, P = .002), and radial LV ε (36 ± 13% vs 54 ± 12%, P = .02) than those without cardiac fibrosis despite similar LV ejection fractions. Patients with fibrosis had lower radial LV ε in the basal inferoseptal wall than patients without cardiac fibrosis (27 ± 17% vs 60 ± 15%, P = .04). Patients with chronic Chagas disease and normal global and segmental LV systolic function on two-dimensional echocardiography had global and segmental LV ε similar to that of control subjects. However, those in the early stages of the cardiac form and cardiac fibrosis had lower global longitudinal, circumferential, and radial LV ε. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Teixeira, Rogério; Monteiro, Ricardo; Dinis, Paulo; Santos, Maria José; Botelho, Ana; Quintal, Nuno; Cardim, Nuno; Gonçalves, Lino
2017-04-01
Vascular mechanics assessed with two-dimensional speckle tracking echocardiography (2D-STE) could be used as a new imaging surrogate of vascular stiffening. The CHA 2 DS 2 -VASc score is considered accurate as an estimate of stroke risk in non-valvular AF, although many potential stroke risk factors have not been included in this scoring method. The purpose of this research is to study the feasibility of evaluating vascular mechanics at the descending aorta in non-valvular AF patients using transesophageal 2D-STE and to analyze the association between descending aortic mechanics and stroke. We prospectively recruited a group of 44 patients referred for a transesophageal echocardiogram (TEE) in the context of cardioversion for non-valvular AF. A short-axis view of the descending aorta, one to two centimeters after the aortic arch was selected for the vascular mechanics assessment with the 2D-STE methodology. The vascular mechanics parameters analyzed were circumferential aortic strain (CAS) and early circumferential aortic strain rate (CASR). A clinical assessment was performed with focus on the past stroke history and the CHA 2 DS 2 -VASc score. The mean age of our cohort was 65 ± 13 years and 75% were men; AF was known for 2.8 ± 2.5 years and it was considered paroxystic in 41% of cases. Waveforms adequate for measuring 2D-STE were present in 85% of the 264 descending aortic wall segments. The mean CAS was 3.5 ± 1.2% and the mean CASR was 0.7 ± 0.3 s -1 . The inter- and intra-observer variability for aortic mechanics was considered adequate. The median CHA 2 DS 2 VASc score was 2 (2-3). As the score increased we noted that both the CAS (r = -0.38, P = 0.01) and the CASR (r = -0.42, P < 0.01) decreased. Over 16% of the AF patients had a past history of stroke. These patients had lower values of both descending aortic strain [2.2 (1.8-2.6) vs. 3.9 (3.3-4.9)%, P < 0.01] and strain rate [0.4 (0.3-0.4) vs. 0.7 (0.6-1.1) s -1 , P < 0.01]. CAS remained independently associated with a past history of stroke after adjustment for the CHA 2 DS 2 VASc score. Our data showed that non-valvular AF patients with a past history of stroke had lower values of aortic mechanics assessed with transesophageal 2D-STE.
Diffraction-controlled backscattering threshold and application to Raman gap
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rose, Harvey A.; Theoretical Division, Los Alamos National Laboratory, Los Alamos, New Mexico 87544; Mounaix, Philippe
2011-04-15
In most classic analytical models of linear stimulated scatter, light diffraction is omitted, a priori. However, modern laser optic typically includes a variant of the random phase plate [Y. Kato et al., Phys. Rev. Lett. 53, 1057 (1984)], resulting in diffraction limited laser intensity fluctuations - or localized speckles - which may result in explosive reflectivity growth as the average laser intensity approaches a critical value [H. A. Rose and D. F. DuBois, Phys. Rev. Lett. 72, 2883 (1994)]. Among the differences between stimulated Raman scatter (SRS) and stimulated Brillouin scatter is that the SRS scattered light diffracts more stronglymore » than the laser light with increase of electron density. This weakens the tendency of the SRS light to closely follow the most amplified paths, diminishing gain. Let G{sub 0} be the one-dimensional power gain exponent of the stimulated scatter. In this paper we show that differential diffraction gives rise to an increase of G{sub 0} at the SRS physical threshold with increase of electron density up to a drastic disruption of SRS as electron density approaches one fourth of its critical value from below. For three wave interaction lengths not small compared to a speckle length, this is a physically robust Raman gap mechanism.« less
Active illuminated space object imaging and tracking simulation
NASA Astrophysics Data System (ADS)
Yue, Yufang; Xie, Xiaogang; Luo, Wen; Zhang, Feizhou; An, Jianzhu
2016-10-01
Optical earth imaging simulation of a space target in orbit and it's extraction in laser illumination condition were discussed. Based on the orbit and corresponding attitude of a satellite, its 3D imaging rendering was built. General simulation platform was researched, which was adaptive to variable 3D satellite models and relative position relationships between satellite and earth detector system. Unified parallel projection technology was proposed in this paper. Furthermore, we denoted that random optical distribution in laser-illuminated condition was a challenge for object discrimination. Great randomicity of laser active illuminating speckles was the primary factor. The conjunction effects of multi-frame accumulation process and some tracking methods such as Meanshift tracking, contour poid, and filter deconvolution were simulated. Comparison of results illustrates that the union of multi-frame accumulation and contour poid was recommendable for laser active illuminated images, which had capacities of high tracking precise and stability for multiple object attitudes.
Estimating Three-Dimensional Orientation of Human Body Parts by Inertial/Magnetic Sensing
Sabatini, Angelo Maria
2011-01-01
User-worn sensing units composed of inertial and magnetic sensors are becoming increasingly popular in various domains, including biomedical engineering, robotics, virtual reality, where they can also be applied for real-time tracking of the orientation of human body parts in the three-dimensional (3D) space. Although they are a promising choice as wearable sensors under many respects, the inertial and magnetic sensors currently in use offer measuring performance that are critical in order to achieve and maintain accurate 3D-orientation estimates, anytime and anywhere. This paper reviews the main sensor fusion and filtering techniques proposed for accurate inertial/magnetic orientation tracking of human body parts; it also gives useful recipes for their actual implementation. PMID:22319365
Estimating three-dimensional orientation of human body parts by inertial/magnetic sensing.
Sabatini, Angelo Maria
2011-01-01
User-worn sensing units composed of inertial and magnetic sensors are becoming increasingly popular in various domains, including biomedical engineering, robotics, virtual reality, where they can also be applied for real-time tracking of the orientation of human body parts in the three-dimensional (3D) space. Although they are a promising choice as wearable sensors under many respects, the inertial and magnetic sensors currently in use offer measuring performance that are critical in order to achieve and maintain accurate 3D-orientation estimates, anytime and anywhere. This paper reviews the main sensor fusion and filtering techniques proposed for accurate inertial/magnetic orientation tracking of human body parts; it also gives useful recipes for their actual implementation.
Spatiotemporal Characterization of a Fibrin Clot Using Quantitative Phase Imaging
Gannavarpu, Rajshekhar; Bhaduri, Basanta; Tangella, Krishnarao; Popescu, Gabriel
2014-01-01
Studying the dynamics of fibrin clot formation and its morphology is an important problem in biology and has significant impact for several scientific and clinical applications. We present a label-free technique based on quantitative phase imaging to address this problem. Using quantitative phase information, we characterized fibrin polymerization in real-time and present a mathematical model describing the transition from liquid to gel state. By exploiting the inherent optical sectioning capability of our instrument, we measured the three-dimensional structure of the fibrin clot. From this data, we evaluated the fractal nature of the fibrin network and extracted the fractal dimension. Our non-invasive and speckle-free approach analyzes the clotting process without the need for external contrast agents. PMID:25386701
Barlow, P.M.
1994-01-01
Steady-state, two-and three-dimensional, ground-water flow models coupled with a particle- tracking program were evaluated to determine their effectiveness in delineating contributing areas of existing and hypothetical public-supply wells pumping from two contrasting stratified-drift aquifers of Cape Cod, Mass. Several of the contri- buting areas delineated by use of the three- dimensional models do not conform to simple ellipsoidal shapes that are typically delineated by use of a two-dimensional analytical and numerical modeling techniques, include dis- continuous areas of the water table, and do not surround the wells. Because two-dimensional areal models do not account for vertical flow, they cannot adequately represent many of the hydro- geologic and well-design variables that were shown to complicate the delineation of contributing areas in these flow systems, including the presence of discrete lenses of 1ow hydraulic conductivity, large ratios of horizontal to ver- tical hydraulic conductivity, shallow streams, partially penetrating supply wells, and 1ow pumping rates (less than 0.1 million gallons per day). Nevertheless, contributing areas delineated for two wells in the simpler of the two flow systems--a thin (less than 100 feet), single- layer, uniform aquifer with near-ideal boundary conditions--were not significantly different for the two- or three-dimensional models of the natural system, for a pumping rate of 0.5 million gallons per day. Use of particle tracking helped identify the source of water to simulated wells, which included precipitation recharge, wastewater return flow, and pond water. Pond water and wastewater return flow accounted for as much as 73 and 40 percent, respectively, of the water captured by simulated wells.
Multiscale morphological filtering for analysis of noisy and complex images
NASA Astrophysics Data System (ADS)
Kher, A.; Mitra, S.
Images acquired with passive sensing techniques suffer from illumination variations and poor local contrasts that create major difficulties in interpretation and identification tasks. On the other hand, images acquired with active sensing techniques based on monochromatic illumination are degraded with speckle noise. Mathematical morphology offers elegant techniques to handle a wide range of image degradation problems. Unlike linear filters, morphological filters do not blur the edges and hence maintain higher image resolution. Their rich mathematical framework facilitates the design and analysis of these filters as well as their hardware implementation. Morphological filters are easier to implement and are more cost effective and efficient than several conventional linear filters. Morphological filters to remove speckle noise while maintaining high resolution and preserving thin image regions that are particularly vulnerable to speckle noise were developed and applied to SAR imagery. These filters used combination of linear (one-dimensional) structuring elements in different (typically four) orientations. Although this approach preserves more details than the simple morphological filters using two-dimensional structuring elements, the limited orientations of one-dimensional elements approximate the fine details of the region boundaries. A more robust filter designed recently overcomes the limitation of the fixed orientations. This filter uses a combination of concave and convex structuring elements. Morphological operators are also useful in extracting features from visible and infrared imagery. A multiresolution image pyramid obtained with successive filtering and a subsampling process aids in the removal of the illumination variations and enhances local contrasts. A morphology-based interpolation scheme was also introduced to reduce intensity discontinuities created in any morphological filtering task. The generality of morphological filtering techniques in extracting information from a wide variety of images obtained with active and passive sensing techniques is discussed. Such techniques are particularly useful in obtaining more information from fusion of complex images by different sensors such as SAR, visible, and infrared.
Multiscale Morphological Filtering for Analysis of Noisy and Complex Images
NASA Technical Reports Server (NTRS)
Kher, A.; Mitra, S.
1993-01-01
Images acquired with passive sensing techniques suffer from illumination variations and poor local contrasts that create major difficulties in interpretation and identification tasks. On the other hand, images acquired with active sensing techniques based on monochromatic illumination are degraded with speckle noise. Mathematical morphology offers elegant techniques to handle a wide range of image degradation problems. Unlike linear filters, morphological filters do not blur the edges and hence maintain higher image resolution. Their rich mathematical framework facilitates the design and analysis of these filters as well as their hardware implementation. Morphological filters are easier to implement and are more cost effective and efficient than several conventional linear filters. Morphological filters to remove speckle noise while maintaining high resolution and preserving thin image regions that are particularly vulnerable to speckle noise were developed and applied to SAR imagery. These filters used combination of linear (one-dimensional) structuring elements in different (typically four) orientations. Although this approach preserves more details than the simple morphological filters using two-dimensional structuring elements, the limited orientations of one-dimensional elements approximate the fine details of the region boundaries. A more robust filter designed recently overcomes the limitation of the fixed orientations. This filter uses a combination of concave and convex structuring elements. Morphological operators are also useful in extracting features from visible and infrared imagery. A multiresolution image pyramid obtained with successive filtering and a subsampling process aids in the removal of the illumination variations and enhances local contrasts. A morphology-based interpolation scheme was also introduced to reduce intensity discontinuities created in any morphological filtering task. The generality of morphological filtering techniques in extracting information from a wide variety of images obtained with active and passive sensing techniques is discussed. Such techniques are particularly useful in obtaining more information from fusion of complex images by different sensors such as SAR, visible, and infrared.
Rice, Tyler B.; Konecky, Soren D.; Owen, Christopher; Choi, Bernard; Tromberg, Bruce J.
2012-01-01
Laser Speckle Imaging (LSI) is fast, noninvasive technique to image particle dynamics in scattering media such as biological tissue. While LSI measurements are independent of the overall intensity of the laser source, we find that spatial variations in the laser source profile can impact measured flow rates. This occurs due to differences in average photon path length across the profile, and is of significant concern because all lasers have some degree of natural Gaussian profile in addition to artifacts potentially caused by projecting optics. Two in vivo measurement are performed to show that flow rates differ based on location with respect to the beam profile. A quantitative analysis is then done through a speckle contrast forward model generated within a coherent Spatial Frequency Domain Imaging (cSFDI) formalism. The model predicts remitted speckle contrast as a function of spatial frequency, optical properties, and scattering dynamics. Comparison with experimental speckle contrast images were done using liquid phantoms with known optical properties for three common beam shapes. cSFDI is found to accurately predict speckle contrast for all beam shapes to within 5% root mean square error. Suggestions for improving beam homogeneity are given, including a widening of the natural beam Gaussian, proper diffusing glass spreading, and flat top shaping using microlens arrays. PMID:22741080
Real-time blood flow visualization using the graphics processing unit
NASA Astrophysics Data System (ADS)
Yang, Owen; Cuccia, David; Choi, Bernard
2011-01-01
Laser speckle imaging (LSI) is a technique in which coherent light incident on a surface produces a reflected speckle pattern that is related to the underlying movement of optical scatterers, such as red blood cells, indicating blood flow. Image-processing algorithms can be applied to produce speckle flow index (SFI) maps of relative blood flow. We present a novel algorithm that employs the NVIDIA Compute Unified Device Architecture (CUDA) platform to perform laser speckle image processing on the graphics processing unit. Software written in C was integrated with CUDA and integrated into a LabVIEW Virtual Instrument (VI) that is interfaced with a monochrome CCD camera able to acquire high-resolution raw speckle images at nearly 10 fps. With the CUDA code integrated into the LabVIEW VI, the processing and display of SFI images were performed also at ~10 fps. We present three video examples depicting real-time flow imaging during a reactive hyperemia maneuver, with fluid flow through an in vitro phantom, and a demonstration of real-time LSI during laser surgery of a port wine stain birthmark.
Real-time blood flow visualization using the graphics processing unit
Yang, Owen; Cuccia, David; Choi, Bernard
2011-01-01
Laser speckle imaging (LSI) is a technique in which coherent light incident on a surface produces a reflected speckle pattern that is related to the underlying movement of optical scatterers, such as red blood cells, indicating blood flow. Image-processing algorithms can be applied to produce speckle flow index (SFI) maps of relative blood flow. We present a novel algorithm that employs the NVIDIA Compute Unified Device Architecture (CUDA) platform to perform laser speckle image processing on the graphics processing unit. Software written in C was integrated with CUDA and integrated into a LabVIEW Virtual Instrument (VI) that is interfaced with a monochrome CCD camera able to acquire high-resolution raw speckle images at nearly 10 fps. With the CUDA code integrated into the LabVIEW VI, the processing and display of SFI images were performed also at ∼10 fps. We present three video examples depicting real-time flow imaging during a reactive hyperemia maneuver, with fluid flow through an in vitro phantom, and a demonstration of real-time LSI during laser surgery of a port wine stain birthmark. PMID:21280915
Assessment of corneal properties based on statistical modeling of OCT speckle
Jesus, Danilo A.; Iskander, D. Robert
2016-01-01
A new approach to assess the properties of the corneal micro-structure in vivo based on the statistical modeling of speckle obtained from Optical Coherence Tomography (OCT) is presented. A number of statistical models were proposed to fit the corneal speckle data obtained from OCT raw image. Short-term changes in corneal properties were studied by inducing corneal swelling whereas age-related changes were observed analyzing data of sixty-five subjects aged between twenty-four and seventy-three years. Generalized Gamma distribution has shown to be the best model, in terms of the Akaike’s Information Criterion, to fit the OCT corneal speckle. Its parameters have shown statistically significant differences (Kruskal-Wallis, p < 0.001) for short and age-related corneal changes. In addition, it was observed that age-related changes influence the corneal biomechanical behaviour when corneal swelling is induced. This study shows that Generalized Gamma distribution can be utilized to modeling corneal speckle in OCT in vivo providing complementary quantified information where micro-structure of corneal tissue is of essence. PMID:28101409
Ultrasound speckle reduction based on fractional order differentiation.
Shao, Dangguo; Zhou, Ting; Liu, Fan; Yi, Sanli; Xiang, Yan; Ma, Lei; Xiong, Xin; He, Jianfeng
2017-07-01
Ultrasound images show a granular pattern of noise known as speckle that diminishes their quality and results in difficulties in diagnosis. To preserve edges and features, this paper proposes a fractional differentiation-based image operator to reduce speckle in ultrasound. An image de-noising model based on fractional partial differential equations with balance relation between k (gradient modulus threshold that controls the conduction) and v (the order of fractional differentiation) was constructed by the effective combination of fractional calculus theory and a partial differential equation, and the numerical algorithm of it was achieved using a fractional differential mask operator. The proposed algorithm has better speckle reduction and structure preservation than the three existing methods [P-M model, the speckle reducing anisotropic diffusion (SRAD) technique, and the detail preserving anisotropic diffusion (DPAD) technique]. And it is significantly faster than bilateral filtering (BF) in producing virtually the same experimental results. Ultrasound phantom testing and in vivo imaging show that the proposed method can improve the quality of an ultrasound image in terms of tissue SNR, CNR, and FOM values.
Three-dimensional mapping of microcircuit correlation structure
Cotton, R. James; Froudarakis, Emmanouil; Storer, Patrick; Saggau, Peter; Tolias, Andreas S.
2013-01-01
Great progress has been made toward understanding the properties of single neurons, yet the principles underlying interactions between neurons remain poorly understood. Given that connectivity in the neocortex is locally dense through both horizontal and vertical connections, it is of particular importance to characterize the activity structure of local populations of neurons arranged in three dimensions. However, techniques for simultaneously measuring microcircuit activity are lacking. We developed an in vivo 3D high-speed, random-access two-photon microscope that is capable of simultaneous 3D motion tracking. This allows imaging from hundreds of neurons at several hundred Hz, while monitoring tissue movement. Given that motion will induce common artifacts across the population, accurate motion tracking is absolutely necessary for studying population activity with random-access based imaging methods. We demonstrate the potential of this imaging technique by measuring the correlation structure of large populations of nearby neurons in the mouse visual cortex, and find that the microcircuit correlation structure is stimulus-dependent. Three-dimensional random access multiphoton imaging with concurrent motion tracking provides a novel, powerful method to characterize the microcircuit activity in vivo. PMID:24133414
A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging.
Amiri, Shahram; Wilson, David R; Masri, Bassam A; Anglin, Carolyn
2014-07-01
C-arm fluoroscopy is frequently used in clinical applications as a low-cost and mobile real-time qualitative assessment tool. C-arms, however, are not widely accepted for applications involving quantitative assessments, mainly due to the lack of reliable and low-cost position tracking methods, as well as adequate calibration and registration techniques. The solution suggested in this work is a tracked C-arm (TC-arm) which employs a low-cost sensor tracking module that can be retrofitted to any conventional C-arm for tracking the individual joints of the device. Registration and offline calibration methods were developed that allow accurate tracking of the gantry and determination of the exact intrinsic and extrinsic parameters of the imaging system for any acquired fluoroscopic image. The performance of the system was evaluated in comparison to an Optotrak[Formula: see text] motion tracking system and by a series of experiments on accurately built ball-bearing phantoms. Accuracies of the system were determined for 2D-3D registration, three-dimensional landmark localization, and for generating panoramic stitched views in simulated intraoperative applications. The system was able to track the center point of the gantry with an accuracy of [Formula: see text] mm or better. Accuracies of 2D-3D registrations were [Formula: see text] mm and [Formula: see text]. Three-dimensional landmark localization had an accuracy of [Formula: see text] of the length (or [Formula: see text] mm) on average, depending on whether the landmarks were located along, above, or across the table. The overall accuracies of the two-dimensional measurements conducted on stitched panoramic images of the femur and lumbar spine were 2.5 [Formula: see text] 2.0 % [Formula: see text] and [Formula: see text], respectively. The TC-arm system has the potential to achieve sophisticated quantitative fluoroscopy assessment capabilities using an existing C-arm imaging system. This technology may be useful to improve the quality of orthopedic surgery and interventional radiology.
Time-resolved x-ray imaging of a laser-induced nanoplasma and its neutral residuals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fluckiger, L.; Rupp, D.; Adolph, M.
The evolution of individual, large gas-phase xenon clusters, turned into a nanoplasma by a high power infrared laser pulse, is tracked from femtoseconds up to nanoseconds after laser excitation via coherent diffractive imaging, using ultra-short soft x-ray free electron laser pulses. A decline of scattering signal at high detection angles with increasing time delay indicates a softening of the cluster surface. Here we demonstrate, for the first time a representative speckle pattern of a new stage of cluster expansion for xenon clusters after a nanosecond irradiation. The analysis of the measured average speckle size and the envelope of the intensitymore » distribution reveals a mean cluster size and length scale of internal density fluctuations. Furthermore, the measured diffraction patterns were reproduced by scattering simulations which assumed that the cluster expands with pronounced internal density fluctuations hundreds of picoseconds after excitation.« less
Time-resolved x-ray imaging of a laser-induced nanoplasma and its neutral residuals
Fluckiger, L.; Rupp, D.; Adolph, M.; ...
2016-04-13
The evolution of individual, large gas-phase xenon clusters, turned into a nanoplasma by a high power infrared laser pulse, is tracked from femtoseconds up to nanoseconds after laser excitation via coherent diffractive imaging, using ultra-short soft x-ray free electron laser pulses. A decline of scattering signal at high detection angles with increasing time delay indicates a softening of the cluster surface. Here we demonstrate, for the first time a representative speckle pattern of a new stage of cluster expansion for xenon clusters after a nanosecond irradiation. The analysis of the measured average speckle size and the envelope of the intensitymore » distribution reveals a mean cluster size and length scale of internal density fluctuations. Furthermore, the measured diffraction patterns were reproduced by scattering simulations which assumed that the cluster expands with pronounced internal density fluctuations hundreds of picoseconds after excitation.« less
Cheong, Fook Chiong; Wong, Chui Ching; Gao, YunFeng; Nai, Mui Hoon; Cui, Yidan; Park, Sungsu; Kenney, Linda J.; Lim, Chwee Teck
2015-01-01
Tracking fast-swimming bacteria in three dimensions can be extremely challenging with current optical techniques and a microscopic approach that can rapidly acquire volumetric information is required. Here, we introduce phase-contrast holographic video microscopy as a solution for the simultaneous tracking of multiple fast moving cells in three dimensions. This technique uses interference patterns formed between the scattered and the incident field to infer the three-dimensional (3D) position and size of bacteria. Using this optical approach, motility dynamics of multiple bacteria in three dimensions, such as speed and turn angles, can be obtained within minutes. We demonstrated the feasibility of this method by effectively tracking multiple bacteria species, including Escherichia coli, Agrobacterium tumefaciens, and Pseudomonas aeruginosa. In addition, we combined our fast 3D imaging technique with a microfluidic device to present an example of a drug/chemical assay to study effects on bacterial motility. PMID:25762336
Dekiff, Markus; Berssenbrügge, Philipp; Kemper, Björn; Denz, Cornelia; Dirksen, Dieter
2015-12-01
A metrology system combining three laser speckle measurement techniques for simultaneous determination of 3D shape and micro- and macroscopic deformations is presented. While microscopic deformations are determined by a combination of Digital Holographic Interferometry (DHI) and Digital Speckle Photography (DSP), macroscopic 3D shape, position and deformation are retrieved by photogrammetry based on digital image correlation of a projected laser speckle pattern. The photogrammetrically obtained data extend the measurement range of the DHI-DSP system and also increase the accuracy of the calculation of the sensitivity vector. Furthermore, a precise assignment of microscopic displacements to the object's macroscopic shape for enhanced visualization is achieved. The approach allows for fast measurements with a simple setup. Key parameters of the system are optimized, and its precision and measurement range are demonstrated. As application examples, the deformation of a mandible model and the shrinkage of dental impression material are measured.
NASA Astrophysics Data System (ADS)
Funamizu, Hideki; Onodera, Yusei; Aizu, Yoshihisa
2018-05-01
In this study, we report color quality improvement of reconstructed images in color digital holography using the speckle method and the spectral estimation. In this technique, an object is illuminated by a speckle field and then an object wave is produced, while a plane wave is used as a reference wave. For three wavelengths, the interference patterns of two coherent waves are recorded as digital holograms on an image sensor. Speckle fields are changed by moving a ground glass plate in an in-plane direction, and a number of holograms are acquired to average the reconstructed images. After the averaging process of images reconstructed from multiple holograms, we use the Wiener estimation method for obtaining spectral transmittance curves in reconstructed images. The color reproducibility in this method is demonstrated and evaluated using a Macbeth color chart film and staining cells of onion.
Light-field and holographic three-dimensional displays [Invited].
Yamaguchi, Masahiro
2016-12-01
A perfect three-dimensional (3D) display that satisfies all depth cues in human vision is possible if a light field can be reproduced exactly as it appeared when it emerged from a real object. The light field can be generated based on either light ray or wavefront reconstruction, with the latter known as holography. This paper first provides an overview of the advances of ray-based and wavefront-based 3D display technologies, including integral photography and holography, and the integration of those technologies with digital information systems. Hardcopy displays have already been used in some applications, whereas the electronic display of a light field is under active investigation. Next, a fundamental question in this technology field is addressed: what is the difference between ray-based and wavefront-based methods for light-field 3D displays? In considering this question, it is of particular interest to look at the technology of holographic stereograms. The phase information in holography contributes to the resolution of a reconstructed image, especially for deep 3D images. Moreover, issues facing the electronic display system of light fields are discussed, including the resolution of the spatial light modulator, the computational techniques of holography, and the speckle in holographic images.
Patterns of Visual Attention to Faces and Objects in Autism Spectrum Disorder
ERIC Educational Resources Information Center
McPartland, James C.; Webb, Sara Jane; Keehn, Brandon; Dawson, Geraldine
2011-01-01
This study used eye-tracking to examine visual attention to faces and objects in adolescents with autism spectrum disorder (ASD) and typical peers. Point of gaze was recorded during passive viewing of images of human faces, inverted human faces, monkey faces, three-dimensional curvilinear objects, and two-dimensional geometric patterns.…
A non-linear piezoelectric actuator calibration using N-dimensional Lissajous figure
NASA Astrophysics Data System (ADS)
Albertazzi, A.; Viotti, M. R.; Veiga, C. L. N.; Fantin, A. V.
2016-08-01
Piezoelectric translators (PZTs) are very often used as phase shifters in interferometry. However, they typically present a non-linear behavior and strong hysteresis. The use of an additional resistive or capacitive sensor make possible to linearize the response of the PZT by feedback control. This approach works well, but makes the device more complex and expensive. A less expensive approach uses a non-linear calibration. In this paper, the authors used data from at least five interferograms to form N-dimensional Lissajous figures to establish the actual relationship between the applied voltages and the resulting phase shifts [1]. N-dimensional Lissajous figures are formed when N sinusoidal signals are combined in an N-dimensional space, where one signal is assigned to each axis. It can be verified that the resulting Ndimensional ellipsis lays in a 2D plane. By fitting an ellipsis equation to the resulting 2D ellipsis it is possible to accurately compute the resulting phase value for each interferogram. In this paper, the relationship between the resulting phase shift and the applied voltage is simultaneously established for a set of 12 increments by a fourth degree polynomial. The results in speckle interferometry show that, after two or three interactions, the calibration error is usually smaller than 1°.
Liu, Chunbo; Chen, Jingqiu; Liu, Jiaxin; Han, Xiang'e
2018-04-16
To obtain a high imaging frame rate, a computational ghost imaging system scheme is proposed based on optical fiber phased array (OFPA). Through high-speed electro-optic modulators, the randomly modulated OFPA can provide much faster speckle projection, which can be precomputed according to the geometry of the fiber array and the known phases for modulation. Receiving the signal light with a low-pixel APD array can effectively decrease the requirement on sampling quantity and computation complexity owing to the reduced data dimensionality while avoiding the image aliasing due to the spatial periodicity of the speckles. The results of analysis and simulation show that the frame rate of the proposed imaging system can be significantly improved compared with traditional systems.
Research on conflict detection algorithm in 3D visualization environment of urban rail transit line
NASA Astrophysics Data System (ADS)
Wang, Li; Xiong, Jing; You, Kuokuo
2017-03-01
In this paper, a method of collision detection is introduced, and the theory of three-dimensional modeling of underground buildings and urban rail lines is realized by rapidly extracting the buildings that are in conflict with the track area in the 3D visualization environment. According to the characteristics of the buildings, CSG and B-rep are used to model the buildings based on CSG and B-rep. On the basis of studying the modeling characteristics, this paper proposes to use the AABB level bounding volume method to detect the first conflict and improve the detection efficiency, and then use the triangular rapid intersection detection algorithm to detect the conflict, and finally determine whether the building collides with the track area. Through the algorithm of this paper, we can quickly extract buildings colliding with the influence area of the track line, so as to help the line design, choose the best route and calculate the cost of land acquisition in the three-dimensional visualization environment.
Advanced shape tracking to improve flexible endoscopic diagnostics
NASA Astrophysics Data System (ADS)
Cao, Caroline G. L.; Wong, Peter Y.; Lilge, Lothar; Gavalis, Robb M.; Xing, Hua; Zamarripa, Nate
2008-03-01
Colonoscopy is the gold standard for screening for inflammatory bowel disease and colorectal cancer. Flexible endoscopes are difficult to manipulate, especially in the distensible and tortuous colon, sometimes leading to disorientation during the procedure and missed diagnosis of lesions. Our goal is to design a navigational aid to guide colonoscopies, presenting a three dimensional representation of the endoscope in real-time. Therefore, a flexible sensor that can track the position and shape of the entire length of the endoscope is needed. We describe a novel shape-tracking technology utilizing a single modified optical fiber. By embedding fluorophores in the buffer of the fiber, we demonstrated a relationship between fluorescence intensity and fiber curvature. As much as a 40% increase in fluorescence intensity was achieved when the fiber's local bend radius decreased from 58 mm to 11 mm. This approach allows for the construction of a three-dimensional shape tracker that is small enough to be easily inserted into the biopsy channel of current endoscopes.
In vivo lateral blood flow velocity measurement using speckle size estimation.
Xu, Tiantian; Hozan, Mohsen; Bashford, Gregory R
2014-05-01
In previous studies, we proposed blood measurement using speckle size estimation, which estimates the lateral component of blood flow within a single image frame based on the observation that the speckle pattern corresponding to blood reflectors (typically red blood cells) stretches (i.e., is "smeared") if blood flow is in the same direction as the electronically controlled transducer line selection in a 2-D image. In this observational study, the clinical viability of ultrasound blood flow velocity measurement using speckle size estimation was investigated and compared with that of conventional spectral Doppler of carotid artery blood flow data collected from human patients in vivo. Ten patients (six male, four female) were recruited. Right carotid artery blood flow data were collected in an interleaved fashion (alternating Doppler and B-mode A-lines) with an Antares Ultrasound Imaging System and transferred to a PC via the Axius Ultrasound Research Interface. The scanning velocity was 77 cm/s, and a 4-s interval of flow data were collected from each subject to cover three to five complete cardiac cycles. Conventional spectral Doppler data were collected simultaneously to compare with estimates made by speckle size estimation. The results indicate that the peak systolic velocities measured with the two methods are comparable (within ±10%) if the scan velocity is greater than or equal to the flow velocity. When scan velocity is slower than peak systolic velocity, the speckle stretch method asymptotes to the scan velocity. Thus, the speckle stretch method is able to accurately measure pure lateral flow, which conventional Doppler cannot do. In addition, an initial comparison of the speckle size estimation and color Doppler methods with respect to computational complexity and data acquisition time indicated potential time savings in blood flow velocity estimation using speckle size estimation. Further studies are needed for calculation of the speckle stretch method across a field of view and combination with an appropriate axial flow estimator. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Three-dimensional tracking of small aquatic organisms using fluorescent nanoparticles.
Ekvall, Mikael T; Bianco, Giuseppe; Linse, Sara; Linke, Heiner; Bäckman, Johan; Hansson, Lars-Anders
2013-01-01
Tracking techniques are vital for the understanding of the biology and ecology of organisms. While such techniques have provided important information on the movement and migration of large animals, such as mammals and birds, scientific advances in understanding the individual behaviour and interactions of small (mm-scale) organisms have been hampered by constraints, such as the sizes of existing tracking devices, in existing tracking methods. By combining biology, chemistry and physics we here present a method that allows three-dimensional (3D) tracking of individual mm-sized aquatic organisms. The method is based on in-vivo labelling of the organisms with fluorescent nanoparticles, so-called quantum dots, and tracking of the organisms in 3D via the quantum-dot fluorescence using a synchronized multiple camera system. It allows for the efficient and simultaneous study of the behaviour of one as well as multiple individuals in large volumes of observation, thus enabling the study of behavioural interactions at the community scale. The method is non-perturbing - we demonstrate that the labelling is not affecting the behavioural response of the organisms - and is applicable over a wide range of taxa, including cladocerans as well as insects, suggesting that our methodological concept opens up for new research fields on individual behaviour of small animals. Hence, this offers opportunities to focus on important biological, ecological and behavioural questions never before possible to address.
Three-dimensional liver motion tracking using real-time two-dimensional MRI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brix, Lau, E-mail: lau.brix@stab.rm.dk; Ringgaard, Steffen; Sørensen, Thomas Sangild
2014-04-15
Purpose: Combined magnetic resonance imaging (MRI) systems and linear accelerators for radiotherapy (MR-Linacs) are currently under development. MRI is noninvasive and nonionizing and can produce images with high soft tissue contrast. However, new tracking methods are required to obtain fast real-time spatial target localization. This study develops and evaluates a method for tracking three-dimensional (3D) respiratory liver motion in two-dimensional (2D) real-time MRI image series with high temporal and spatial resolution. Methods: The proposed method for 3D tracking in 2D real-time MRI series has three steps: (1) Recording of a 3D MRI scan and selection of a blood vessel (ormore » tumor) structure to be tracked in subsequent 2D MRI series. (2) Generation of a library of 2D image templates oriented parallel to the 2D MRI image series by reslicing and resampling the 3D MRI scan. (3) 3D tracking of the selected structure in each real-time 2D image by finding the template and template position that yield the highest normalized cross correlation coefficient with the image. Since the tracked structure has a known 3D position relative to each template, the selection and 2D localization of a specific template translates into quantification of both the through-plane and in-plane position of the structure. As a proof of principle, 3D tracking of liver blood vessel structures was performed in five healthy volunteers in two 5.4 Hz axial, sagittal, and coronal real-time 2D MRI series of 30 s duration. In each 2D MRI series, the 3D localization was carried out twice, using nonoverlapping template libraries, which resulted in a total of 12 estimated 3D trajectories per volunteer. Validation tests carried out to support the tracking algorithm included quantification of the breathing induced 3D liver motion and liver motion directionality for the volunteers, and comparison of 2D MRI estimated positions of a structure in a watermelon with the actual positions. Results: Axial, sagittal, and coronal 2D MRI series yielded 3D respiratory motion curves for all volunteers. The motion directionality and amplitude were very similar when measured directly as in-plane motion or estimated indirectly as through-plane motion. The mean peak-to-peak breathing amplitude was 1.6 mm (left-right), 11.0 mm (craniocaudal), and 2.5 mm (anterior-posterior). The position of the watermelon structure was estimated in 2D MRI images with a root-mean-square error of 0.52 mm (in-plane) and 0.87 mm (through-plane). Conclusions: A method for 3D tracking in 2D MRI series was developed and demonstrated for liver tracking in volunteers. The method would allow real-time 3D localization with integrated MR-Linac systems.« less
A Study of Running Safety and Ride Comfort of Floating Tracks for High-Speed Train
NASA Astrophysics Data System (ADS)
Watanabe, Tsutomu; Sogabe, Masamichi; Yamazaki, Takayuki
In order to reduce train-induced vibration, many floating tracks have been used, however, for only low-speed trains because we are not sure whether riding comfort and running safety can be maintained on floating tracks for high speed train. The authors, in this study, carried out an analysis of dynamic response and running quality of various floating tracks for high-speed train like Shinkansen. We used a simulation program, DIASTARS for the analysis. In this program, the Shinkansen vehicle is represented by a model of three dimensions consisting of a body, two trucks, and four wheelsets connected to each other with springs and dampers. The floating tracks were modeled by three-dimensional finite element method. In this study, the wheel load fluctuation and vehicle body accelerations were investigated by a dynamic interaction analysis between the vehicle and track with the train speed as parameters.
De Boeck, Bart W; Toma, Aurel; Kiencke, Stephanie; Dehnert, Christoph; Zügel, Stefanie; Siebenmann, Christoph; Auinger, Katja; Buser, Peter T; Maggiorini, Marco; Kaufmann, Beat A
2018-03-01
Changes in left ventricular (LV) torsion have been related to LV geometry in patients with concomitant long-standing myocardial disease or pulmonary hypertension (PH). We evaluated the effect of acute high altitude-induced isolated PH on LV geometry, volumes, systolic function, and torsional mechanics. Twenty-three volunteers were prospectively studied at low altitude and after the second (D3) and third night (D4) at high altitude (4,559 m). LV ejection fraction, multidirectional strains and torsion, LV volumes, sphericity, and eccentricity were derived by speckle-tracking on three-dimensional echocardiographic data sets. Pulmonary pressure was estimated from the transtricuspid pressure gradient (TRPG), LV preload from end-diastolic LV volume, and transmitral over mitral annular E velocity (E/e'). At high altitude, oxygen saturation decreased by 15%-20%, heart rate and cardiac index increased by 15%-20%, and TRPG increased from 21 ± 2 to 37 ± 9 mm Hg (P < .01). LV volumes, preload, ejection fraction, multidirectional strains, and sphericity remained unaffected, but diastolic (1.04 ± 0.07 to 1.09 ± 0.09 on D3/D4, P < .05) and systolic (1.00 ± 0.06 to 1.08 ± 0.1 [D3] and 1.06 ± 0.07 [D4], P < .05) eccentricity slightly increased, indicating mild septal flattening. LV torsion decreased from 2.14 ± 0.85 to 1.34 ± 0.68 (P < .05) and 1.65 ± 0.54 (P = .08) degrees/cm on D3/D4, respectively. Changes in torsion showed a weak inverse relationship to changes in systolic (r = -0.369, P = .013) and diastolic (r = -0.329, P = .032) eccentricity but not to changes in TRPG, heart rate or preload. High-altitude exposure was associated with mild septal flattening of the LV and reduced ventricular torsion at unchanged global LV function and preload, suggesting a relation between LV geometry and torsional mechanics. Copyright © 2017 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
2017-12-08
A solar flare associated with the coronal mass ejection seen in this image generated a flurry of fast-moving solar protons. As each one hits the CCD camera on SOHO, it produces a brief snow-like speckle in the image. Credit: NASA/SOHO CME WEEK: What To See in CME Images Two main types of explosions occur on the sun: solar flares and coronal mass ejections. Unlike the energy and x-rays produced in a solar flare – which can reach Earth at the speed of light in eight minutes – coronal mass ejections are giant, expanding clouds of solar material that take one to three days to reach Earth. Once at Earth, these ejections, also called CMEs, can impact satellites in space or interfere with radio communications. During CME WEEK from Sept. 22 to 26, 2014, we explore different aspects of these giant eruptions that surge out from the star we live with. When a coronal mass ejection blasts off the sun, scientists rely on instruments called coronagraphs to track their progress. Coronagraphs block out the bright light of the sun, so that the much fainter material in the solar atmosphere -- including CMEs -- can be seen in the surrounding space. CMEs appear in these images as expanding shells of material from the sun's atmosphere -- sometimes a core of colder, solar material (called a filament) from near the sun's surface moves in the center. But mapping out such three-dimensional components from a two-dimensional image isn't easy. Watch the slideshow to find out how scientists interpret what they see in CME pictures. The images in the slideshow are from the three sets of coronagraphs NASA currently has in space. One is on the joint European Space Agency and NASA Solar and Heliospheric Observatory, or SOHO. SOHO launched in 1995, and sits between Earth and the sun about a million miles away from Earth. The other two coronagraphs are on the two spacecraft of the NASA Solar Terrestrial Relations Observatory, or STEREO, mission, which launched in 2006. The two STEREO spacecraft are both currently viewing the far side of the sun. Together these instruments help scientists create a three-dimensional model of any CME as its journey unfolds through interplanetary space. Such information can show why a given characteristic of a CME close to the sun might lead to a given effect near Earth, or any other planet in the solar system...NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
NASA Astrophysics Data System (ADS)
Uzzal, R. U. A.; Ahmed, A. K. W.; Bhat, R. B.
2013-11-01
This paper presents dynamic contact loads at wheel-rail contact point in a three-dimensional railway vehicle-track model as well as dynamic response at vehicle-track component levels in the presence of wheel flats. The 17-degrees of freedom lumped mass vehicle is modelled as a full car body, two bogies and four wheelsets, whereas the railway track is modelled as two parallel Timoshenko beams periodically supported by lumped masses representing the sleepers. The rail beam is also supported by nonlinear spring and damper elements representing the railpad and ballast. In order to ensure the interactions between the railpads, a shear parameter beneath the rail beams has also been considered into the model. The wheel-rail contact is modelled using nonlinear Hertzian contact theory. In order to solve the coupled partial and ordinary differential equations of the vehicle-track system, modal analysis method is employed. Idealised Haversine wheel flats with the rounded corner are included in the wheel-rail contact model. The developed model is validated with the existing measured and analytical data available in the literature. The nonlinear model is then employed to investigate the wheel-rail impact forces that arise in the wheel-rail interface due to the presence of wheel flats. The validated model is further employed to investigate the dynamic responses of vehicle and track components in terms of displacement, velocity, and acceleration in the presence of single wheel flat.
Measuring three-dimensional interaction potentials using optical interference.
Mojarad, Nassir; Sandoghdar, Vahid; Krishnan, Madhavi
2013-04-22
We describe the application of three-dimensional (3D) scattering interferometric (iSCAT) imaging to the measurement of spatial interaction potentials for nano-objects in solution. We study electrostatically trapped gold particles in a nanofluidic device and present details on axial particle localization in the presence of a strongly reflecting interface. Our results demonstrate high-speed (~kHz) particle tracking with subnanometer localization precision in the axial and average 2.5 nm in the lateral dimension. A comparison of the measured levitation heights of trapped particles with the calculated values for traps of various geometries reveals good agreement. Our work demonstrates that iSCAT imaging delivers label-free, high-speed and accurate 3D tracking of nano-objects conducive to probing weak and long-range interaction potentials in solution.
NASA Astrophysics Data System (ADS)
Davtyan, Arman; Biermanns, Andreas; Loffeld, Otmar; Pietsch, Ullrich
2016-06-01
Coherent x-ray diffraction imaging is used to measure diffraction patterns from individual highly defective nanowires, showing a complex speckle pattern instead of well-defined Bragg peaks. The approach is tested for nanowires of 500 nm diameter and 500 nm height predominately composed by zinc-blende (ZB) and twinned zinc-blende (TZB) phase domains. Phase retrieval is used to reconstruct the measured 2-dimensional intensity patterns recorded from single nanowires with 3.48 nm and 0.98 nm spatial resolution. Whereas the speckle amplitudes and distribution are perfectly reconstructed, no unique solution could be obtained for the phase structure. The number of phase switches is found to be proportional to the number of measured speckles and follows a narrow number distribution. Using data with 0.98 nm spatial resolution the mean number of phase switches is in reasonable agreement with estimates taken from TEM. However, since the resolved phase domain still is 3-4 times larger than a single GaAs bilayer we explain the non-ambiguous phase reconstruction by the fact that depending on starting phase and sequence of subroutines used during the phase retrieval the retrieved phase domain host a different sequence of randomly stacked bilayers. Modelling possible arrangements of bilayer sequences within a phase domain demonstrate that the complex speckle patterns measured can indeed be explained by the random arrangement of the ZB and TZB phase domains.
Three dimensional time-gated tracking of non-blinking quantum dots in live cells
DeVore, Matthew S.; Werner, James H.; Goodwin, Peter M.; ...
2015-03-12
Single particle tracking has provided a wealth of information about biophysical processes such as motor protein transport and diffusion in cell membranes. However, motion out of the plane of the microscope or blinking of the fluorescent probe used as a label generally limits observation times to several seconds. Here, we overcome these limitations by using novel non-blinking quantum dots as probes and employing a custom 3D tracking microscope to actively follow motion in three dimensions (3D) in live cells. As a result, signal-to-noise is improved in the cellular milieu through the use of pulsed excitation and time-gated detection.