Analytical model for the threshold voltage of III-V nanowire transistors including quantum effects
NASA Astrophysics Data System (ADS)
Marin, E. G.; Ruiz, F. G.; Tienda-Luna, I. M.; Godoy, A.; Gámiz, F.
2014-02-01
In this work we propose an analytical model for the threshold voltage (VT) of III-V cylindrical nanowires, that takes into consideration the two dimensional quantum confinement of the carriers, the Fermi-Dirac statistics, the wave-function penetration into the gate insulator and the non-parabolicity of the conduction band structure. A simple expression for VT is obtained assuming some suitable approximations. The model results are compared to those of a 2D self consistent Schrödinger-Poisson solver, demonstrating a good fit for different III-V materials, insulator thicknesses and nanowire sizes with diameter down to 5 nm. The VT dependence on the confinement effective mass is discussed. The different contributions to VT are analyzed showing significant variations among different III-V materials.
NASA Astrophysics Data System (ADS)
Zhang, Z.; Cardwell, D.; Sasikumar, A.; Kyle, E. C. H.; Chen, J.; Zhang, E. X.; Fleetwood, D. M.; Schrimpf, R. D.; Speck, J. S.; Arehart, A. R.; Ringel, S. A.
2016-04-01
The impact of proton irradiation on the threshold voltage (VT) of AlGaN/GaN heterostructures is systematically investigated to enhance the understanding of a primary component of the degradation of irradiated high electron mobility transistors. The value of VT was found to increase monotonically as a function of 1.8 MeV proton fluence in a sub-linear manner reaching 0.63 V at a fluence of 1 × 1014 cm-2. Silvaco Atlas simulations of VT shifts caused by GaN buffer traps using experimentally measured introduction rates, and energy levels closely match the experimental results. Different buffer designs lead to different VT dependences on proton irradiation, confirming that deep, acceptor-like defects in the GaN buffer are primarily responsible for the observed VT shifts. The proton irradiation induced VT shifts are found to depend on the barrier thickness in a linear fashion; thus, scaling the barrier thickness could be an effective way to reduce such degradation.
NASA Astrophysics Data System (ADS)
Wang, Ming-Tsong; Hsu, De-Cheng; Juan, Pi-Chun; Wang, Y. L.; Lee, Joseph Ya-min
2010-09-01
Metal-oxide-semiconductor capacitors and n-channel metal-oxide-semiconductor field-effect transistors with La2O3 gate dielectric were fabricated. The positive bias temperature instability was studied. The degradation of threshold voltage (ΔVT) showed an exponential dependence on the stress time in the temperature range from 25 to 75 °C. The degradation of subthreshold slope (ΔS) and gate leakage (IG) with stress voltage was also measured. The degradation of VT is attributed to the oxide trap charges Qot. The extracted activation energy of 0.2 eV is related to a degradation dominated by the release of atomic hydrogen in La2O3 thin films.
NASA Astrophysics Data System (ADS)
Li, Yi; Liu, Qi; Cai, Jing; Li, Yun; Shi, Yi; Wang, Xizhang; Hu, Zheng
2014-06-01
This study investigates the remarkable reduction in the threshold voltage (VT) of pentacene-based thin film transistors with pentacene/copper phthalocyanine (CuPc) sandwich configuration. This reduction is accompanied by increased mobility and lowered sub-threshold slope (S). Sandwich devices coated with a 5 nm layer of CuPc layer are compared with conventional top-contact devices, and results indicate that VT decreased significantly from -20.4 V to -0.2 V, that mobility increased from 0.18 cm2/Vs to 0.51 cm2/Vs, and that S was reduced from 4.1 V/dec to 2.9 V/dec. However, the on/off current ratio remains at 105. This enhanced performance could be attributed to the reduction in charge trap density by the incorporated CuPc layer. Results suggest that this method is simple and effectively generates pentacene-based organic thin film transistors with high mobility and low VT.
Adaptive Circuits for the 0.5-V Nanoscale CMOS Era
NASA Astrophysics Data System (ADS)
Itoh, Kiyoo; Yamaoka, Masanao; Oshima, Takashi
The minimum operating voltage, Vmin, of nanoscale CMOS LSIs is investigated to breach the 1-V wall that we are facing in the 65-nm device generation, and open the door to the below 0.5-V era. A new method using speed variation is proposed to evaluate Vmin. It shows that Vmin is very sensitive to the lowest necessary threshold voltage, Vt0, of MOSFETs and to threshold-voltage variations, ΔVt, which become more significant with device scaling. There is thus a need for low-Vt0 circuits and ΔVt-immune MOSFETs to reduce Vmin. For memory-rich LSIs, the SRAM block is particularly problematic because it has the highest Vmin. Various techniques are thus proposed to reduce the Vmin: using RAM repair, shortening the data line, up-sizing, and using more relaxed MOSFET scaling. To effectively reduce Vmin of other circuit blocks, dual-Vt0 and dual-VDD circuits using gate-source reverse biasing, temporary activation, and series connection of another small low-Vt0 MOSFET are proposed. They are dynamic logic circuits enabling the power-delay product of the conventional static CMOS inverter to be reduced to 0.09 at a 0.2-V supply, and a DRAM dynamic sense amplifier and power switches operable at below 0.5V. In addition, a fully-depleted structure (FD-SOI) and fin-type structure (FinFET) for Vt-immune MOSFETs are discussed in terms of their low-voltage potential and challenges. As a result, the height up-scalable FinFETs turns out to be quite effective to reduce Vmin to less than 0.5V, if combined with the low-Vt0 circuits. For mixed-signal LSIs, investigation of low-voltage potential of analog circuits, especially for comparators and operational amplifiers, reveals that simple inverter op-amps, in which the low gain and nonlinearity are compensated for by digitally assisted analog designs, are crucial to 0.5-V operations. Finally, it is emphasized that the development of relevant devices and fabrication processes is the key to the achievement of 0.5-V nanoscale LSIs.
Stable indium oxide thin-film transistors with fast threshold voltage recovery
NASA Astrophysics Data System (ADS)
Vygranenko, Yuriy; Wang, Kai; Nathan, Arokia
2007-12-01
Stable thin-film transistors (TFTs) with semiconducting indium oxide channel and silicon dioxide gate dielectric were fabricated by reactive ion beam assisted evaporation and plasma-enhanced chemical vapor deposition. The field-effect mobility is 3.3cm2/Vs, along with an on/off current ratio of 106, and subthreshold slope of 0.5V/decade. When subject to long-term gate bias stress, the TFTs show fast recovery of the threshold voltage (VT) when relaxed without annealing, suggesting that charge trapping at the interface and/or in the bulk gate dielectric to be the dominant mechanism underlying VT instability. Device performance and stability make indium oxide TFTs promising for display applications.
Nastasi, Michael Anthony; Wang, Yongqiang; Fraboni, Beatrice; Cosseddu, Piero; Bonfiglio, Annalisa
2013-06-11
Organic thin film devices that included an organic thin film subjected to a selected dose of a selected energy of ions exhibited a stabilized mobility (.mu.) and threshold voltage (VT), a decrease in contact resistance R.sub.C, and an extended operational lifetime that did not degrade after 2000 hours of operation in the air.
NASA Astrophysics Data System (ADS)
Ho, Ching-Yuan; Chang, Yaw-Jen
2016-02-01
Both aluminum (Al) and copper (Cu), acting as transmission lines in the hydrogenated amorphous silicon of a thin film transistor (a-Si:H TFT), were studied to investigate electrical degradation including electron-migration (EM) and threshold voltage (Vt) stability and recovery performance. Under long-term current stress, the Cu material exhibited excellent resistance to EM properties, but a passivated SiNx crack was observed due to fast heat conductivity. By applying electrical stress on the gate and drain for 5 × 104 s, the power-law time dependency of the threshold voltage shift (ΔVt) indicated that the defective state creation dominated the TFT device's instability. The presence of drain stress increased the overall ΔVt because the high longitudinal field induced impact ionization and then, enhanced hot-carrier-induced electron trapping within the gate SiNx dielectric. An annealing effect prompted a stressed a-Si:H TFT back to virgin status. This study proposes better ΔVt stability and excellent resistance against electron-migration in a Cu gate device which can be considered as a candidate for a transmission line on prolonged TFT applications.
NASA Astrophysics Data System (ADS)
Zhong, Donglai; Zhao, Chenyi; Liu, Lijun; Zhang, Zhiyong; Peng, Lian-Mao
2018-04-01
In this letter, we report a gate engineering method to adjust threshold voltage of carbon nanotube (CNT) based field-effect transistors (FETs) continuously in a wide range, which makes the application of CNT FETs especially in digital integrated circuits (ICs) easier. Top-gated FETs are fabricated using solution-processed CNT network films with stacking Pd and Sc films as gate electrodes. By decreasing the thickness of the lower layer metal (Pd) from 20 nm to zero, the effective work function of the gate decreases, thus tuning the threshold voltage (Vt) of CNT FETs from -1.0 V to 0.2 V. The continuous adjustment of threshold voltage through gate engineering lays a solid foundation for multi-threshold technology in CNT based ICs, which then can simultaneously provide high performance and low power circuit modules on one chip.
Low-Voltage InGaZnO Thin Film Transistors with Small Sub-Threshold Swing.
Cheng, C H; Chou, K I; Hsu, H H
2015-02-01
We demonstrate a low-voltage driven, indium-gallium-zinc oxide thin-film transistor using high-κ LaAlO3 gate dielectric. A low VT of 0.42 V, very small sub-threshold swing of 68 mV/dec, field-effect mobility of 4.1 cm2/Ns and low operation voltage of 1.4 V were reached simultaneously in LaAlO3/IGZO TFT device. This low-power and small SS TFT has the potential for fast switching speed and low power applications.
Low Voltage Electrowetting-on-Dielectric Platform using Multi-Layer Insulators
Lin, Yan-You; Evans, Randall D.; Welch, Erin; Hsu, Bang-Ning; Madison, Andrew C.; Fair, Richard B.
2010-01-01
A low voltage, two-level-metal, and multi-layer insulator electrowetting-on-dielectric (EWD) platform is presented. Dispensing 300pl droplets from 140nl closed on-chip reservoirs was accomplished with as little as 11.4V solely through EWD forces, and the actuation threshold voltage was 7.2V with a 1Hz voltage switching rate between electrodes. EWD devices were fabricated with a multilayer insulator consisting of 135nm sputtered tantalum pentoxide (Ta2O5) and 180nm parylene C coated with 70nm of CYTOP. Furthermore, the minimum actuation threshold voltage followed a previously published scaling model for the threshold voltage, VT, which is proportional to (t/εr)1/2, where t and εr are the insulator thickness and dielectric constant respectively. Device threshold voltages are compared for several insulator thicknesses (200nm, 500nm, and 1µm), different dielectric materials (parylene C and tantalum pentoxide), and homogeneous versus heterogeneous compositions. Additionally, we used a two-level-metal fabrication process, which enables the fabrication of smaller and denser electrodes with high interconnect routing flexibility. We also have achieved low dispensing and actuation voltages for scaled devices with 30pl droplets. PMID:20953362
Temporal and voltage stress stability of high performance indium-zinc-oxide thin film transistors
NASA Astrophysics Data System (ADS)
Song, Yang; Katsman, Alexander; Butcher, Amy L.; Paine, David C.; Zaslavsky, Alexander
2017-10-01
Thin film transistors (TFTs) based on transparent oxide semiconductors, such as indium zinc oxide (IZO), are of interest due to their improved characteristics compared to traditional a-Si TFTs. Previously, we reported on top-gated IZO TFTs with an in-situ formed HfO2 gate insulator and IZO active channel, showing high performance: on/off ratio of ∼107, threshold voltage VT near zero, extracted low-field mobility μ0 = 95 cm2/V·s, and near-perfect subthreshold slope at 62 mV/decade. Since device stability is essential for technological applications, in this paper we report on the temporal and voltage stress stability of IZO TFTs. Our devices exhibit a small negative VT shift as they age, consistent with an increasing carrier density resulting from an increasing oxygen vacancy concentration in the channel. Under gate bias stress, freshly annealed TFTs show a negative VT shift during negative VG gate bias stress, while aged (>1 week) TFTs show a positive VT shift during negative VG stress. This indicates two competing mechanisms, which we identify as the field-enhanced generation of oxygen vacancies and the field-assisted migration of oxygen vacancies, respectively. A simplified kinetic model of the vacancy concentration evolution in the IZO channel under electrical stress is provided.
Kumaresan, Yogeenth; Pak, Yusin; Lim, Namsoo; Lee, Ryeri; Song, Hui; Kim, Tae Heon; Choi, Boran; Jung, Gun Young
2016-06-01
We demonstrated the effect of active layer (channel) thickness and annealing temperature on the electrical performances of Ga2O3-In2O3-ZnO (GIZO) thin film transistor (TFT) having nanoscale channel width (W/L: 500 nm/100 μm). We found that the electron carrier concentration of the channel was decreased significantly with increasing the annealing temperature (100 degrees C to 300 degrees C). Accordingly, the threshold voltage (V(T)) was shifted towards positive voltage (-12.2 V to 10.8 V). In case of channel thickness, the V(T) was shifted towards negative voltage with increasing the channel thickness. The device with channel thickness of 90 nm annealed at 200 degrees C revealed the best device performances in terms of mobility (10.86 cm2/Vs) and V(T) (0.8 V). The effect of channel length was also studied, in which the channel width, thickness and annealing temperature were kept constant such as 500 nm, 90 nm and 200 degrees C, respectively. The channel length influenced the on-current level significantly with small variation of V(T), resulting in lower value of on/off current ratio with increasing the channel length. The device with channel length of 0.5 μm showed enhanced on/off current ratio of 10(6) with minimum V(T) of 0.26 V.
Through thick and thin: tuning the threshold voltage in organic field-effect transistors.
Martínez Hardigree, Josué F; Katz, Howard E
2014-04-15
Organic semiconductors (OSCs) constitute a class of organic materials containing densely packed, overlapping conjugated molecular moieties that enable charge carrier transport. Their unique optical, electrical, and magnetic properties have been investigated for use in next-generation electronic devices, from roll-up displays and radiofrequency identification (RFID) to biological sensors. The organic field-effect transistor (OFET) is the key active element for many of these applications, but the high values, poor definition, and long-term instability of the threshold voltage (V(T)) in OFETs remain barriers to realization of their full potential because the power and control circuitry necessary to compensate for overvoltages and drifting set points decrease OFET practicality. The drifting phenomenon has been widely observed and generally termed "bias stress." Research on the mechanisms responsible for this poor V(T) control has revealed a strong dependence on the physical order and chemical makeup of the interfaces between OSCs and adjacent materials in the OFET architecture. In this Account, we review the state of the art for tuning OFET performance via chemical designs and physical processes that manipulate V(T). This parameter gets to the heart of OFET operation, as it determines the voltage regimes where OFETs are either ON or OFF, the basis for the logical function of the devices. One obvious way to decrease the magnitude and variability of V(T) is to work with thinner and higher permittivity gate dielectrics. From the perspective of interfacial engineering, we evaluate various methods that we and others have developed, from electrostatic poling of gate dielectrics to molecular design of substituted alkyl chains. Corona charging of dielectric surfaces, a method for charging the surface of an insulating material using a constant high-voltage field, is a brute force means of shifting the effective gate voltage applied to a gate dielectric. A gentler and more direct method is to apply surface voltage to dielectric interfaces by direct contact or postprocess biasing; these methods could also be adapted for high throughput printing sequences. Dielectric hydrophobicity is an important chemical property determining the stability of the surface charges. Functional organic monolayers applied to dielectrics, using the surface attachment chemistry made available from "self-assembled" monolayer chemistry, provide local electric fields without any biasing process at all. To the extent that the monolayer molecules can be printed, these are also suitable for high throughput processes. Finally, we briefly consider V(T) control in the context of device integration and reliability, such as the role of contact resistance in affecting this parameter.
NASA Astrophysics Data System (ADS)
Hu, Cheng-Yu; Nakatani, Katsutoshi; Kawai, Hiroji; Ao, Jin-Ping; Ohno, Yasuo
To improve the high voltage performance of AlGaN/GaN heterojunction field effect transistors (HFETs), we have fabricated AlGaN/GaN HFETs with p-GaN epi-layer on sapphire substrate with an ohmic contact to the p-GaN (p-sub HFET). Substrate bias dependent threshold voltage variation (VT-VSUB) was used to directly determine the doping concentration profile in the buffer layer. This VT-VSUB method was developed from Si MOSFET. For HFETs, the insulator is formed by epitaxially grown and heterogeneous semiconductor layer while for Si MOSFETs the insulator is amorphous SiO2. Except that HFETs have higher channel mobility due to the epitaxial insulator/semiconductor interface, HFETs and Si MOSFETs are basically the same in the respect of device physics. Based on these considerations, the feasibility of this VT-VSUB method for AlGaN/GaN HFETs was discussed. In the end, the buffer layer doping concentration was measured to be 2 × 1017cm-3, p-type, which is well consistent with the Mg concentration obtained from secondary ion mass spectroscopy (SIMS) measurement.
NASA Astrophysics Data System (ADS)
Devynck, M.; Tardy, P.; Wantz, G.; Nicolas, Y.; Hirsch, L.
2011-12-01
The effect of OTS (octadecyltrichlorosilane) Self-Assembled Monolayer (SAM) grafted on SiO2 gate dielectric of pentacene-based OFETs (organic field-effect transistors) is investigated. A significant improvement of the charge mobility (μ), up to 0.74 cm2/V s, is reached thanks to OTS treatment. However, in spite of improved performances, several drawbacks, such as an increase in mobility dispersion, substantial hysteresis in IDS-VG characteristics and high threshold voltages (VT), are observed. Changing solvent and deposition method turns out to have no significant effect on the mobility dispersion. A more accurate approach on the evolution of the mobility and the threshold voltage dispersion with OTS storage time highlights the effect of the OTS solution aging. Even if no difference is evidenced in the surface energy and roughness of the OTS layer, electrical characteristics exhibit considerable deterioration with OTS solution storage time. Using an "aged" OTS solution, opened under air, kept under argon and distilled before use, results in an increase of the IDS-VG hysteresis as well as in VT and in mobility dispersion. In comparison, fresh-OTS-based OFETs present a very low hysteresis, a threshold voltage close to 0 and a much lower mobility dispersion. It is demonstrated that aged OTS solutions contain impurities that are not removed by distillation process, which leads to a less densely packed layer causing interfacial charge traps thus deteriorated performances.
Ventilatory thresholds determined from HRV: comparison of 2 methods in obese adolescents.
Quinart, S; Mourot, L; Nègre, V; Simon-Rigaud, M-L; Nicolet-Guénat, M; Bertrand, A-M; Meneveau, N; Mougin, F
2014-03-01
The development of personalised training programmes is crucial in the management of obesity. We evaluated the ability of 2 heart rate variability analyses to determine ventilatory thresholds (VT) in obese adolescents. 20 adolescents (mean age 14.3±1.6 years and body mass index z-score 4.2±0.1) performed an incremental test to exhaustion before and after a 9-month multidisciplinary management programme. The first (VT1) and second (VT2) ventilatory thresholds were identified by the reference method (gas exchanges). We recorded RR intervals to estimate VT1 and VT2 from heart rate variability using time-domain analysis and time-varying spectral-domain analysis. The coefficient correlations between thresholds were higher with spectral-domain analysis compared to time-domain analysis: Heart rate at VT1: r=0.91 vs. =0.66 and VT2: r=0.91 vs. =0.66; power at VT1: r=0.91 vs. =0.74 and VT2: r=0.93 vs. =0.78; spectral-domain vs. time-domain analysis respectively). No systematic bias in heart rate at VT1 and VT2 with standard deviations <6 bpm were found, confirming that spectral-domain analysis could replace the reference method for the detection of ventilatory thresholds. Furthermore, this technique is sensitive to rehabilitation and re-training, which underlines its utility in clinical practice. This inexpensive and non-invasive tool is promising for prescribing physical activity programs in obese adolescents. © Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
Hayama, K.; Ohyama, H.; Simoen, E.; Rafí, J. M.; Mercha, A.; Claeys, C.
2004-04-01
The degradation of the electrical properties of deep submicron metal-oxide-semiconductor field-effect transistors (MOSFETs) by 2 MeV electron irradiation at high temperatures was studied. The irradiation temperatures were 30, 100, 150 and 200 °C, and the fluence was fixed at 1015e/cm2. For most experimental conditions, the threshold voltage (VT) is observed to reduce in absolute value both for n- and p-MOSFETs. This reduction is most pronounced at 100 °C, as at this irradiation temperature, the radiation-induced density of interface traps is highest. It is proposed that hydrogen neutralization of the dopants in the substrate plays a key role, whereby the hydrogen is released from the gate by the 2 MeV electrons.
NASA Astrophysics Data System (ADS)
Liao, Po-Yung; Chang, Ting-Chang; Su, Wan-Ching; Chen, Bo-Wei; Chen, Li-Hui; Hsieh, Tien-Yu; Yang, Chung-Yi; Chang, Kuan-Chang; Zhang, Sheng-Dong; Huang, Yen-Yu; Chang, Hsi-Ming; Chiang, Shin-Chuan
2017-06-01
This letter investigates repeated uniaxial mechanical stress-induced degradation behavior in flexible amorphous In-Ga-Zn-O thin-film transistors (TFTs) of different geometric structures. Two types of via-contact structure TFTs are investigated: symmetrical and UI structure (TFTs with I- and U-shaped asymmetric electrodes). After repeated mechanical stress, I-V curves for the symmetrical structure show a significant negative threshold voltage (VT) shift, due to mechanical stress-induced oxygen vacancy generation. However, degradation in the UI structure TFTs after stress is a negative VT shift along with the parasitic transistor characteristic in the forward-operation mode, with this hump not evident in the reverse-operation mode. This asymmetrical degradation is clarified by the mechanical strain simulation of the UI TFTs.
Gaskill, S E; Walker, A J; Serfass, R A; Bouchard, C; Gagnon, J; Rao, D C; Skinner, J S; Wilmore, J H; Leon, A S
2001-11-01
The purpose of this study was to evaluate the effect of exercise training intensity relative to the ventilatory threshold (VT) on changes in work (watts) and VO2 at the ventilatory threshold and at maximal exercise in previously sedentary participants in the HERITAGE Family Study. We hypothesized that those who exercised below their VT would improve less in VO2 at the ventilatory threshold (VO2vt) and VO2max than those who trained at an intensity greater than their VT. Supervised cycle ergometer training was performed at the 4 participating clinical centers, 3 times a week for 20 weeks. Exercise training progressed from the HR corresponding to 55% VO2max for 30 minutes to the HR associated with 75% VO2max for 50 minutes for the final 6 weeks. VT was determined at baseline and after exercise training using standardized methods. 432 sedentary white and black men (n = 224) and women (n = 208), aged 17 to 65 years, were retrospectively divided into groups based on whether exercise training was initiated below, at, or above VT. 1) Training intensity (relative to VT) accounting for about 26% of the improvement in VO2vt (R2 = 0.26, p < 0.0001). 2) The absolute intensity of training in watts (W) accounted for approximately 56% of the training effect at VT (R2 = 0.56, p < 0.0001) with post-training watts at VT (VT(watts)) being not significantly different than W during training (p > 0.70). 3) Training intensity (relative to VT) had no effect on DeltaVO2max. These data clearly show that as a result of aerobic training both the VO2 and W associated with VT respond and become similar to the absolute intensity of sustained (3 x /week for 50 min) aerobic exercise training. Higher intensities of exercise, relative to VT, result in larger gains in VO2vt but not in VO2max.
Combine Flash-Based FPGA TID and Long-Term Retention Reliabilities Through VT Shift
NASA Astrophysics Data System (ADS)
Wang, Jih-Jong; Rezzak, Nadia; Dsilva, Durwyn; Xue, Fengliang; Samiee, Salim; Singaraju, Pavan; Jia, James; Nguyen, Victor; Hawley, Frank; Hamdy, Esmat
2016-08-01
Reliability test results of data retention and total ionizing dose (TID) in 65 nm Flash-based field programmable gate array (FPGA) are presented. Long-chain inverter design is recommended for reliability evaluation because it is the worst case design for both effects. Based on preliminary test data, both issues are unified and modeled by one natural decay equation. The relative contributions of TID induced threshold-voltage shift and retention mechanisms are evaluated by analyzing test data.
Kuroki, Kenji; Nogami, Akihiko; Igarashi, Miyako; Masuda, Keita; Kowase, Shinya; Kurosaki, Kenji; Komatsu, Yuki; Naruse, Yoshihisa; Machino, Takeshi; Yamasaki, Hiro; Xu, Dongzhu; Murakoshi, Nobuyuki; Sekiguchi, Yukio; Aonuma, Kazutaka
2018-04-01
Several conducting channels of ventricular tachycardia (VT) can be identified using voltage limit adjustment (VLA) of substrate mapping. However, the sensitivity or specificity to predict a VT isthmus is not high by using VLA alone. This study aimed to evaluate the efficacy of the combined use of VLA and fast-Fourier transform analysis to predict VT isthmuses. VLA and fast-Fourier transform analyses of local ventricular bipolar electrograms during sinus rhythm were performed in 9 postinfarction patients who underwent catheter ablation for a total of 13 monomorphic VTs. Relatively higher voltage areas on an electroanatomical map were defined as high voltage channels (HVCs), and relatively higher fast-Fourier transform areas were defined as high-frequency channels (HFCs). HVCs were classified into full or partial HVCs (the entire or >30% of HVC can be detectable, respectively). Twelve full HVCs were identified in 7 of 9 patients. HFCs were located on 7 of 12 full HVCs. Five VT isthmuses (71%) were included in the 7 full HVC+/HFC+ sites, whereas no VT isthmus was found in the 5 full HVC+/HFC- sites. HFCs were identical to 9 of 16 partial HVCs. Eight VT isthmuses (89%) were included in the 9 partial HVC+/HFC+ sites, whereas no VT isthmus was found in the 7 partial HVC+/HFC- sites. All HVC+/HFC+ sites predicted VT isthmus with a sensitivity of 100% and a specificity of 80%. Combined use of VLA and fast-Fourier transform analysis may be a useful method to detect VT isthmuses. © 2018 American Heart Association, Inc.
NASA Astrophysics Data System (ADS)
Chen, Charlene; Abe, Katsumi; Fung, Tze-Ching; Kumomi, Hideya; Kanicki, Jerzy
2009-03-01
In this paper, we analyze application of amorphous In-Ga-Zn-O thin film transistors (a-InGaZnO TFTs) to current-scaling pixel electrode circuit that could be used for 3-in. quarter video graphics array (QVGA) full color active-matrix organic light-emitting displays (AM-OLEDs). Simulation results, based on a-InGaZnO TFT and OLED experimental data, show that both device sizes and operational voltages can be reduced when compare to the same circuit using hydrogenated amorphous silicon (a-Si:H) TFTs. Moreover, the a-InGaZnO TFT pixel circuit can compensate for the drive TFT threshold voltage variation (ΔVT) within acceptable operating error range.
Luo, Jian-yu; Wang, Xiao-yuan; Cai, Tian-bin; Jiang, Wen-fang
2013-02-01
To investigate the setting of ventilator volume tidal (VT) and airway pressure alarm threshold during cardiopulmonary resuscitation (CPR) by continuous extra-sternum heart compression. Forty cases with respiration and cardiac arrest in the department of critical care medicine were randomly divided into low VT ventilation group and conventional VT group. Both groups were given the volume control mode. In the low VT ventilation group, VT was set on 6 - 7 ml/kg, and high pressure alarm threshold was adjusted to 60 cm H2O by the conventional 40 cm H2O during CPR. In the conventional VT group, VT and high pressure alarm threshold were set at 8 - 12 ml/kg and 40 cm H2O, respectively. Real-time actual VT, peak inspiratory pressure (PIP), and arterial blood gas test, blood lactic acid at 10 minutes and 30 minutes after CPR were observed. At 10 minutes after CPR, in the low VT ventilation group, arterial blood pH, arterial partial pressure of oxygen (PaO2), arterial partial pressure of carbon dioxide (PaCO2), HCO3(-), arterial oxygen saturation (SaO2) and blood lactic acid were better as compared with those in the conventional VT ventilation group (pH: 7.21±0.09 vs. 7.13±0.07, PaO2: 45.35±5.92 mm Hg vs. 40.70±4.70 mm Hg, PaCO2: 57.10±7.59 mm Hg vs. 61.60±5.47 mm Hg, HCO3(-): 18.50±3.50 mmol/L vs. 14.75±2.65 mmol/L, SaO2: 0.796±0.069 vs. 0.699±0.066, blood lactic acid: 7.07±1.60 mmol/L vs. 8.13±1.56 mmol/L, all P<0.05). The success rate of resuscitation in the low VT ventilation group was higher than that of the conventional VT ventilation group (45% vs. 15%, P<0.05), and PIP (cm H2O) of low VT ventilation group was lower than that of the conventional VT group (37.25±7.99 cm H2O vs. 42.70±7.40 cm H2O, P<0.05). In all the patients in both groups barotrauma did not occur. The strategy of low ventilator VT (6 - 7 ml/kg) with appropriate elevation of airway pressure alarm threshold was better than that of conventional ventilation setting, with no increase in incidence of barotraumas during CPR.
Kendall, Kristina L; Smith, Abbie E; Graef, Jennifer L; Walter, Ashley A; Moon, Jordan R; Lockwood, Christopher M; Beck, Travis W; Cramer, Joel T; Stout, Jeffrey R
2010-01-01
The submaximal electromyographic fatigue threshold test (EMG(FT)) has been shown to be highly correlated to ventilatory threshold (VT) as determined from maximal graded exercise tests (GXTs). Recently, a prediction equation was developed using the EMG(FT) value to predict VT. The aim of this study, therefore, was to determine if this new equation could accurately track changes in VT after high-intensity interval training (HIIT). Eighteen recreationally trained men (mean +/- SD; age 22.4 +/- 3.2 years) performed a GXT to determine maximal oxygen consumption rate (V(O2)peak) and VT using breath-by-breath spirometry. Participants also completed a discontinuous incremental cycle ergometer test to determine their EMGFT value. A total of four 2-minute work bouts were completed to obtain 15-second averages of the electromyographic amplitude. The resulting slopes from each successive work bout were used to calculate EMG(FT). The EMG(FT) value from each participant was used to estimate VT from the recently developed equation. All participants trained 3 days a week for 6 weeks. Training consisted of 5 sets of 2-minute work bouts with 1 minute of rest in between. Repeated-measures analysis of variance indicated no significant difference between actual and predicted VT values after 3 weeks of training. However, there was a significant difference between the actual and predicted VT values after 6 weeks of training. These findings suggest that the EMG(FT) may be useful when tracking changes in VT after 3 weeks of HIIT in recreationally trained individuals. However, the use of EMG(FT) to predict VT does not seem to be valid for tracking changes after 6 weeks of HIIT. At this time, it is not recommended that EMG(FT) be used to predict and track changes in VT.
Electrical switching studies on Si15Te85-xCux bulk (1 ≤ x ≤ 5) glasses
NASA Astrophysics Data System (ADS)
Roy, Diptoshi; Nadig, Chinmayi H. S.; Krishnan, Aravindh; Karanam, Akshath; Abhilash, R.; Jagannatha K., B.; Das, Chandasree
2018-05-01
Bulk ingots of Si15Te85-xCux (1 ≤ x ≤ 5) glasses are concocted by typical melt quenching technique. XRD validate the non-crystalline feature of the prepared quenched sample. The samples are found to display threshold type of electrical switching behavior. The switching behavior on all the samples is noticed without any disturbances. Compositional dependence of threshold voltage of Si15Te85-xCux (1 ≤ x ≤ 5) glasses has been studied and it has been found that VT increases as the atomic percentage of dopant (copper) increases in the host matrix. The distinguished behavior has been envisaged and correlated to the improvement in network connectivity and rigidity with the addition of Cu.
Ding, Shaojie; Qian, Min; Qian, Hong; Zhang, Xuejuan
2016-12-28
The stochastic Hodgkin-Huxley model is one of the best-known examples of piecewise deterministic Markov processes (PDMPs), in which the electrical potential across a cell membrane, V(t), is coupled with a mesoscopic Markov jump process representing the stochastic opening and closing of ion channels embedded in the membrane. The rates of the channel kinetics, in turn, are voltage-dependent. Due to this interdependence, an accurate and efficient sampling of the time evolution of the hybrid stochastic systems has been challenging. The current exact simulation methods require solving a voltage-dependent hitting time problem for multiple path-dependent intensity functions with random thresholds. This paper proposes a simulation algorithm that approximates an alternative representation of the exact solution by fitting the log-survival function of the inter-jump dwell time, H(t), with a piecewise linear one. The latter uses interpolation points that are chosen according to the time evolution of the H(t), as the numerical solution to the coupled ordinary differential equations of V(t) and H(t). This computational method can be applied to all PDMPs. Pathwise convergence of the approximated sample trajectories to the exact solution is proven, and error estimates are provided. Comparison with a previous algorithm that is based on piecewise constant approximation is also presented.
Accurate analytical modeling of junctionless DG-MOSFET by green's function approach
NASA Astrophysics Data System (ADS)
Nandi, Ashutosh; Pandey, Nilesh
2017-11-01
An accurate analytical model of Junctionless double gate MOSFET (JL-DG-MOSFET) in the subthreshold regime of operation is developed in this work using green's function approach. The approach considers 2-D mixed boundary conditions and multi-zone techniques to provide an exact analytical solution to 2-D Poisson's equation. The Fourier coefficients are calculated correctly to derive the potential equations that are further used to model the channel current and subthreshold slope of the device. The threshold voltage roll-off is computed from parallel shifts of Ids-Vgs curves between the long channel and short-channel devices. It is observed that the green's function approach of solving 2-D Poisson's equation in both oxide and silicon region can accurately predict channel potential, subthreshold current (Isub), threshold voltage (Vt) roll-off and subthreshold slope (SS) of both long & short channel devices designed with different doping concentrations and higher as well as lower tsi/tox ratio. All the analytical model results are verified through comparisons with TCAD Sentaurus simulation results. It is observed that the model matches quite well with TCAD device simulations.
Comparison of Ventilatory Measures and 20 km Time Trial Performance.
Peveler, Willard W; Shew, Brandy; Johnson, Samantha; Sanders, Gabe; Kollock, Roger
2017-01-01
Performance threshold measures are used to predict cycling performance. Previous research has focused on long time trials (≥ 40 km) using power at ventilatory threshold and respiratory threshold to estimate time trial performance. As intensity greatly differs during shorter time trails applying findings from longer time trials may not be appropriate. The use of heart rate measures to determine 20 km time trial performance has yet to be examined. The purpose of this study was to determine the effectiveness of heart rate measures at ventilatory threshold (VE/VO 2 Plotted and VT determined by software) and respiratory threshold (RER of 0.95, 1.00, and 1.05) to predict 20 km time trial performance. Eighteen cyclists completed a VO 2max protocol and two 20 km time trials. Average heart rates from 20 km time trials were compared with heart rates from performance threshold measures (VT plotted, VT software, and an RER at 0.95, 1.00, and 1.05) using repeated measures ANOVA. Significance was set a priori at P ≤ 0.05. The only measure not found to be significantly different in relation to time trial performance was HR at an RER of 1.00 (166.61±12.70 bpm vs. 165.89 ± 9.56 bpm, p = .671). VT plotting and VT determined by software were found to underestimate time trial performance by 3% and 8% respectively. From these findings it is recommended to use heart rate at a RER of 1.00 in order to determine 20 km time trial intensity.
Value of right ventricular mapping in patients with postinfarction ventricular tachycardia.
Yokokawa, Miki; Good, Eric; Crawford, Thomas; Chugh, Aman; Pelosi, Frank; Latchamsetty, Rakesh; Oral, Hakan; Morady, Fred; Bogun, Frank
2012-06-01
Postinfarction ventricular tachycardia (VT) typically involves the left ventricular endocardium. Right ventricular involvement in the arrhythmogenic substrate of postinfarction VT is considered unusual. To assess the role of right ventricular mapping and ablation in patients with prior septal myocardial infarction. From among 37 consecutive patients with recurrent postinfarction VT, 18 patients with evidence of left ventricular septal involvement of myocardial infarction were identified; these patients were the subjects of this report. In these 18 patients, 166 VTs (cycle length 372 ± 117 ms) were induced. Right ventricular voltage mapping was performed in all 18 patients with left ventricular septal myocardial infarction. Right ventricular voltage mapping showed areas of low voltage in 11 patients; pace mapping from these areas revealed matching pace maps for 17 VTs, and radiofrequency ablation from the right ventricular endocardium but not the left ventricular endocardium eliminated 14 of 17 VTs. VTs with critical components in the right ventricle had a left bundle branch block morphology that had similar characteristics as left bundle branch block VTs with critical areas involving the left ventricular septum. Patients with right ventricular VT breakthrough sites had a lower ejection fraction than did patients without VT breaking out on the right ventricular septum (18% ± 5% vs 33% ± 15%; P = .01). Right ventricular mapping and ablation may be necessary in order to eliminate all inducible VTs in patients with postinfarction VT. More than half the patients with septal myocardial infarction have right ventricular septal areas that are critical for postinfarction VT and that cannot be eliminated by left ventricular ablation alone. Copyright © 2012 Heart Rhythm Society. All rights reserved.
Anaerobic threshold determination through ventilatory and electromyographics parameters.
Gassi, E R; Bankoff, A D P
2010-01-01
The aim of present study was to compare the alterations in electromyography signs with Ventilatory Threshold (VT). Had been part of the study eight men, amateur cyclists and triathletes (25.25 +/- 6.96 years), that they had exercised themselves in a mechanical cicloergometer, a cadence of 80 RPM and with the increased intensity being in 25 W/min until the exhaustion. The VT was determined by a non-linear increase in VE/VO2 without any increase in VE/VCO2 and compared with the intensity corresponding to break point of amplitude EMG sign during the incremental exercise. The EMG--Fatigue Threshold (FT) and Ventilatory Threshold (VT) parameters used were the power, the time, absolute and relative VO2, ventilation (VE), the heart hate (HH) and the subjective perception of the effort. The results had not shown to difference in none of the variable selected for the corresponding intensity to VT and FT--EMG of the muscles lateralis vastus and femoris rectus. The parameters used in the comparison between the electromyographic indicators and ventilatory were the load, the time, absolute VO2 and relative to corporal mass, to ventilation (VE), the heart frequency (HH) and the Subjective Perception of the Effort (SPE).
Influence of Gate Dielectrics, Electrodes and Channel Width on OFET Characteristics
NASA Astrophysics Data System (ADS)
Liyana, V. P.; Stephania, A. M.; Shiju, K.; Predeep, P.
2015-06-01
Organic Field Effect Transistors (OFET) possess wide applications in large area electronics owing to their attractive features like easy fabrication process, light weight, flexibility, cost effectiveness etc. But instability, high operational voltages and low carrier mobility act as inhibitors to commercialization of OFETs and various approaches were tried on a regular basis so as to make it viable. In this work, Poly 3-hexylthiophene-2,5diyl (P3HT) based OFETs with bottom-contact top-gate configuration using Poly vinyl alcohol (PVA) and Poly (methyl methacrylate) (PMMA) as gate dielectrics, aluminium and copper as source-drain electrodes are investigated. An effort is made to compare the effect of these dielectric materials and electrodes on the performance of OFET. Also, an attempt has been made to optimize the channel width of the device. These devices are characterised with mobility (μ), threshold voltage (VT), on-off ratio (Ion/Ioff) and their comparative analysis is reported.
A short latency vestibular evoked potential (VsEP) produced by bone-conducted acoustic stimulation
NASA Astrophysics Data System (ADS)
McAngus Todd, Neil P.; Rosengren, Sally M.; Colebatch, James G.
2003-12-01
In this paper data are presented from an experiment which provides evidence for the existence of a short latency, acoustically evoked potential of probable vestibular origin. The experiment was conducted in two phases using bone-conducted acoustic stimulation. In the first phase subjects were stimulated with 6-ms, 500-Hz tone bursts in order to obtain the threshold VT for vestibular evoked myogenic potentials (VEMP). It was confirmed that the difference between bone-conducted auditory and acoustic vestibular thresholds was slightly over 30 dB. The estimated threshold was then used as a reference value in the second part of the experiment to stimulate subjects over a range of intensities from -6 to +18 dB (re:VT). Averaged EEG recordings were made with eight Ag/AgCl electrodes placed on the scalp at Fpz, F3, F4, F7, F8, Cz, T3, and T4 according to the 10-20 system. Below VT auditory midlatency responses (MLRs) were observed. Above VT two additional potentials appeared: a positivity at about 10 ms (P10) which was maximal at Cz, and a negativity at about 15 ms (N15) which was maximal at Fpz. Extrapolation of the growth functions for the P10 and N15 indicated a threshold close to VT, consistent with a vestibular origin of these potentials. Given the low threshold of vestibular acoustic sensitivity it is possible that this mode may make a contribution to the detection of and affective responses to loud low frequency sounds. The evoked potentials may also have application as a noninvasive and nontraumatic test of vestibular projections to the cortex.
Spectroscopic analysis of electron trapping levels in pentacene field-effect transistors
NASA Astrophysics Data System (ADS)
Park, Chang Bum
2014-08-01
Electron trapping phenomena have been investigated with respect to the energy levels of localized trap states and bias-induced device instability effects in pentacene field-effect transistors. The mechanism of the photoinduced threshold voltage shift (ΔVT) is presented by providing a ΔVT model governed by the electron trapping. The trap-and-release behaviour functionalized by photo-irradiation also shows that the trap state for electrons is associated with the energy levels in different positions in the forbidden gap of pentacene. Spectroscopic analysis identifies two kinds of electron trap states distributed above and below the energy of 2.5 eV in the band gap of the pentacene crystal. The study of photocurrent spectra shows the specific trap levels of electrons in energy space that play a substantial role in causing device instability. The shallow and deep trapping states are distributed at two centroidal energy levels of ˜1.8 and ˜2.67 eV in the pentacene band gap. Moreover, we present a systematic energy profile of electron trap states in the pentacene crystal for the first time.
Miyamoto, Koji; Noda, Takashi; Satomi, Kazuhiro; Wada, Mitsuru; Nakajima, Ikutaro; Ishibashi, Kohei; Okamura, Hideo; Noguchi, Teruo; Anzai, Toshihisa; Yasuda, Satoshi; Ogawa, Hisao; Shimizu, Wataru; Aiba, Takeshi; Kamakura, Shiro; Kusano, Kengo
2016-08-01
Patients with ischemic and non-ischemic cardiomyopathy often have substrate for ventricular tachycardia (VT) in the endocardium (ENDO), epicardium (EPI), and/or intramural. Although it has been reported that the ENDO unipolar (UNI) voltage map is useful in detecting EPI substrate, its feasibility to detect intramural scarring and its usefulness in radiofrequency catheter ablation (RFCA) remain unclear. To assess the relationship between the left ventricle (LV) ENDO UNI voltage map and the LV EPI bipolar (BIP) voltage map, and to determine the usefulness of the ENDO UNI voltage map to guide RFCA for VT in patients with cardiomyopathy undergoing combined ENDO- and EPI RFCA. Eleven patients with VT undergoing detailed ENDO and EPI electroanatomical mapping of the LV were included (mean age 59 ± 11 years, 9 men). We assessed the value of the LV ENDO UNI voltage map in identifying EPI and/or intramural substrate in these 11 patients with non-ischemic or ischemic cardiomyopathy. The underlying heart disease was dilated cardiomyopathy in 4 patients, cardiac sarcoidosis in 3, hypertrophic cardiomyopathy in 2, and ischemic heart disease in 2 patients. The mean LV ejection fraction was 24 ± 7 %. The low voltage zone (LVZ) was defined as <1.5 mV for LV ENDO BIP electrograms (EGMs), <8.3 mV for LV ENDO UNI EGMs, and <1.0 mV for LV EPI BIP EGMs. The surface area of each LVZ was measured. We also measured the LVZ of the spatial overlap between ENDO UNI and EPI BIP voltage maps using the transparency mode on CARTO software. We performed RFCA at the ENDO and EPI based on activation and/or substrate maps, targeting the LVZ and/or abnormal EGMs. The LVZ was present in the LV ENDO BIP voltage map in 10 of 11 patients (42 ± 33 cm(2)), and in the LV ENDO UNI voltage map in 10 of 11 patients (72 ± 45 cm(2)). The LVZ was present in the EPI BIP voltage map in 9 of 11 patients (70 ± 61 cm(2)), and the LVZ in the ENDO UNI voltage map was also seen in all 9 patients. The location of the LVZ in the EPI BIP map matched that in 45 ± 28 % of ENDO UNI voltage maps. The LVZ in the ENDO UNI voltage map was larger than that in the EPI BIP voltage map in 6 of 11 patients, and RFCA failed in 5 of these 6 patients. In the remaining 5 patients with a smaller LVZ in the ENDO UNI voltage map compared with the EPI BIP voltage map or no LVZ both at ENDO UNI and EPI BIP voltage map, VT was successfully eliminated in 4 of 5 patients. The LV ENDO UNI voltage map is useful in detecting EPI substrate in patients with cardiomyopathy. A larger LVZ in the ENDO UNI voltage map compared to that in the EPI BIP voltage map may indicate the presence of intramural substrate, which leads to difficulty in eliminating VT, even with combined ENDO- and EPI RFCA.
Shiraishi, Yasuyuki; Katsumata, Yoshinori; Sadahiro, Taketaro; Azuma, Koichiro; Akita, Keitaro; Isobe, Sarasa; Yashima, Fumiaki; Miyamoto, Kazutaka; Nishiyama, Takahiko; Tamura, Yuichi; Kimura, Takehiro; Nishiyama, Nobuhiro; Aizawa, Yoshiyasu; Fukuda, Keiichi; Takatsuki, Seiji
2018-01-07
It has never been possible to immediately evaluate heart rate variability (HRV) during exercise. We aimed to visualize the real-time changes in the power spectrum of HRV during exercise and to investigate its relationship to the ventilatory threshold (VT). Thirty healthy subjects (29.1±5.7 years of age) and 35 consecutive patients (59.0±13.2 years of age) with myocardial infarctions underwent cardiopulmonary exercise tests with an RAMP protocol ergometer. The HRV was continuously assessed with power spectral analyses using the maximum entropy method and projected on a screen without delay. During exercise, a significant decrease in the high frequency (HF) was followed by a drastic shift in the power spectrum of the HRV with a periodic augmentation in the low frequency/HF (L/H) and steady low HF. When the HRV threshold (HRVT) was defined as conversion from a predominant high frequency (HF) to a predominant low frequency/HF (L/H), the VO 2 at the HRVT (HRVT-VO 2 ) was substantially correlated with the VO 2 at the lactate threshold and VT) in the healthy subjects ( r =0.853 and 0.921, respectively). The mean difference between each threshold (0.65 mL/kg per minute for lactate threshold and HRVT, 0.53 mL/kg per minute for VT and HRVT) was nonsignificant ( P >0.05). Furthermore, the HRVT-VO 2 was also correlated with the VT-VO 2 in these myocardial infarction patients ( r =0.867), and the mean difference was -0.72 mL/kg per minute and was nonsignificant ( P >0.05). A HRV analysis with our method enabled real-time visualization of the changes in the power spectrum during exercise. This can provide additional information for detecting the VT. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
NASA Astrophysics Data System (ADS)
Pradeep, Krishna; Poiroux, Thierry; Scheer, Patrick; Juge, André; Gouget, Gilles; Ghibaudo, Gérard
2018-07-01
This work details the analysis of wafer level global process variability in 28 nm FD-SOI using split C-V measurements. The proposed approach initially evaluates the native on wafer process variability using efficient extraction methods on split C-V measurements. The on-wafer threshold voltage (VT) variability is first studied and modeled using a simple analytical model. Then, a statistical model based on the Leti-UTSOI compact model is proposed to describe the total C-V variability in different bias conditions. This statistical model is finally used to study the contribution of each process parameter to the total C-V variability.
Simulation study on AlGaN/GaN diode with Γ-shaped anode for ultra-low turn-on voltage
NASA Astrophysics Data System (ADS)
Wang, Zeheng; Chen, Wanjun; Wang, Fangzhou; Cao, Jun; Sun, Ruize; Ren, Kailin; Luo, Yi; Guo, Songnan; Wang, Zirui; Jin, Xiaosheng; Yang, Lei; Zhang, Bo
2018-05-01
An ultra-low turn-on voltage (VT) Γ-shaped anode AlGaN/GaN Schottky barrier diode (GA-SBD) is proposed via modeling and simulation for the first time, in which a Γ-shaped anode consists of a metal-2DEG junction together with a metal-AlGaN junction beside a shallowly recessed MIS field plate (MFP). An analytic forward current-voltage model matching the simulation results well is presented where an ultra-low VT of 0.08 V is obtained. The turn-on and blocking mechanisms are investigated to reveal the GA-SBD's great potential for applications of highly efficient power ICs.
1983-02-01
in ZT position, adjust Rx and VT to give the following conditions simul taneously: a) Vc to be specifiied value * RMS Volts. b) VRX Vz. 3. Record: RX...conditions simultaneously: a) V to be specified value as before.c b) VRX Vc. 2. Record: Rx = Q_ ; VT = ; VR =Vc (Volts). C. CALCULATE VOLTAGE AND...2 _V2 cos 8 = cos (180-,) = VRX V2 . VT 2VRX* V Z =R (cos + isino) = Rz + JWTLZ (OHMS) VT x10 (MILLIAMPERES) E(Rx+Rz)2 + LZ2 2 • =TLz COIL "Q
The Effects of a Duathlon Simulation on Ventilatory Threshold and Running Economy
Berry, Nathaniel T.; Wideman, Laurie; Shields, Edgar W.; Battaglini, Claudio L.
2016-01-01
Multisport events continue to grow in popularity among recreational, amateur, and professional athletes around the world. This study aimed to determine the compounding effects of the initial run and cycling legs of an International Triathlon Union (ITU) Duathlon simulation on maximal oxygen uptake (VO2max), ventilatory threshold (VT) and running economy (RE) within a thermoneutral, laboratory controlled setting. Seven highly trained multisport athletes completed three trials; Trial-1 consisted of a speed only VO2max treadmill protocol (SOVO2max) to determine VO2max, VT, and RE during a single-bout run; Trial-2 consisted of a 10 km run at 98% of VT followed by an incremental VO2max test on the cycle ergometer; Trial-3 consisted of a 10 km run and 30 km cycling bout at 98% of VT followed by a speed only treadmill test to determine the compounding effects of the initial legs of a duathlon on VO2max, VT, and RE. A repeated measures ANOVA was performed to determine differences between variables across trials. No difference in VO2max, VT (%VO2max), maximal HR, or maximal RPE was observed across trials. Oxygen consumption at VT was significantly lower during Trial-3 compared to Trial-1 (p = 0.01). This decrease was coupled with a significant reduction in running speed at VT (p = 0.015). A significant interaction between trial and running speed indicate that RE was significantly altered during Trial-3 compared to Trial-1 (p < 0.001). The first two legs of a laboratory based duathlon simulation negatively impact VT and RE. Our findings may provide a useful method to evaluate multisport athletes since a single-bout incremental treadmill test fails to reveal important alterations in physiological thresholds. Key points Decrease in relative oxygen uptake at VT (ml·kg-1·min-1) during the final leg of a duathlon simulation, compared to a single-bout maximal run. We observed a decrease in running speed at VT during the final leg of a duathlon simulation; resulting in an increase of more than 2 minutes to complete a 5 km run. During our study, highly trained athletes were unable to complete the final 5 km run at the same intensity that they completed the initial 10 km run (in a laboratory setting). A better understanding, and determination, of training loads during multisport training may help to better periodize training programs; additional research is required. PMID:27274661
Baturina, T I; Mironov, A Yu; Vinokur, V M; Baklanov, M R; Strunk, C
2007-12-21
We investigate low-temperature transport properties of thin TiN superconducting films in the vicinity of the disorder-driven superconductor-insulator transition. In a zero magnetic field, we find an extremely sharp separation between superconducting and insulating phases, evidencing a direct superconductor-insulator transition without an intermediate metallic phase. At moderate temperatures, in the insulating films we reveal thermally activated conductivity with the magnetic field-dependent activation energy. At very low temperatures, we observe a zero-conductivity state, which is destroyed at some depinning threshold voltage V{T}. These findings indicate the formation of a distinct collective state of the localized Cooper pairs in the critical region at both sides of the transition.
Pohl, A; Heuwieser, W; Burfeind, O
2014-07-01
The objective of this study was to evaluate whether milk temperature (MT) measured by automatic milking system (AMS) is a reliable indicator of body temperature of dairy cows and whether cows with fever could be detected. Data loggers (Minilog 8, Vemco Ltd., Halifax, NS, Canada) measuring body temperature were inserted for 7 ± 1 d into the vaginal cavity of 31 dairy cows and programmed to take 1 reading/min. Milk temperature was recorded at each milking event by the AMS, and values from the vaginal loggers were paired with the corresponding MT. The correlation (r) between vaginal temperature (VT) and MT was 0.52. Vaginal temperature was higher (39.1 ± 0.4°C) than MT (38.6 ± 0.7°C) with a mean difference of 0.5 ± 0.6°C. The ability of MT to identify cows with fever was assessed using 2 approaches. In the first approach, VT could indicate fever at any time of the day, whereas MT could display fever only during the milking events of a given day. Different definitions of fever based on thresholds of VT and duration exceeding these thresholds were constructed. Different thresholds of MT were tested to distinguish between cows with and without fever. The combination of 39.0°C as a threshold for MT and 39.5°C for at least 2h/d as a threshold for VT resulted in the highest combination of sensitivity (0.65) and specificity (0.65). In the second approach, we evaluated whether MT could identify cows with fever at a given milking event. A threshold of MT >38.7°C delivered the best combination of sensitivity (0.77) and specificity (0.66) when fever was defined as VT ≥39.5°C. Therefore, MT measured by AMS can be indicative of fever in dairy cows to a limited extent. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Pulse Thermal Processing for Low Thermal Budget Integration of IGZO Thin Film Transistors
Noh, Joo Hyon; Joshi, Pooran C.; Kuruganti, Teja; ...
2014-11-26
Pulse thermal processing (PTP) has been explored for low thermal budget integration of indium gallium zinc oxide (IGZO) thin film transistors (TFTs). The IGZO TFTs are exposed to a broadband (0.2-1.4 m) arc lamp radiation spectrum with 100 pulses of 1 msec pulse width. The impact of radiant exposure power on the TFT performance was analyzed in terms of the switching characteristics and bias stress reliability characteristics, respectively. The PTP treated IGZO TFTs with power density of 3.95 kW/cm 2 and 0.1 sec total irradiation time showed comparable switching properties, at significantly lower thermal budget, to furnace annealed IGZO TFT.more » The typical field effect mobility FE, threshold voltage VT, and sub-threshold gate swing S.S were calculated to be 7.8 cm 2/ V s, 8.1 V, and 0.22 V/ decade, respectively. The observed performance shows promise for low thermal budget TFT integration on flexible substrates exploiting the large-area, scalable PTP technology.« less
Pulse Thermal Processing for Low Thermal Budget Integration of IGZO Thin Film Transistors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Noh, Joo Hyon; Joshi, Pooran C.; Kuruganti, Teja
Pulse thermal processing (PTP) has been explored for low thermal budget integration of indium gallium zinc oxide (IGZO) thin film transistors (TFTs). The IGZO TFTs are exposed to a broadband (0.2-1.4 m) arc lamp radiation spectrum with 100 pulses of 1 msec pulse width. The impact of radiant exposure power on the TFT performance was analyzed in terms of the switching characteristics and bias stress reliability characteristics, respectively. The PTP treated IGZO TFTs with power density of 3.95 kW/cm 2 and 0.1 sec total irradiation time showed comparable switching properties, at significantly lower thermal budget, to furnace annealed IGZO TFT.more » The typical field effect mobility FE, threshold voltage VT, and sub-threshold gate swing S.S were calculated to be 7.8 cm 2/ V s, 8.1 V, and 0.22 V/ decade, respectively. The observed performance shows promise for low thermal budget TFT integration on flexible substrates exploiting the large-area, scalable PTP technology.« less
NASA Astrophysics Data System (ADS)
Liu, Yongxun; Matsukawa, Takashi; Endo, Kazuhiko; O'uchi, Shinichi; Tsukada, Junichi; Yamauchi, Hiromi; Ishikawa, Yuki; Mizubayashi, Wataru; Morita, Yukinori; Migita, Shinji; Ota, Hiroyuki; Masahara, Meishoku
2014-01-01
Three-dimensional (3D) fin-channel charge trapping (CT) flash memories with different gate materials of physical-vapor-deposited (PVD) titanium nitride (TiN) and n+-polycrystalline silicon (poly-Si) have successfully been fabricated by using (100)-oriented silicon-on-insulator (SOI) wafers and orientation-dependent wet etching. Electrical characteristics of the fabricated flash memories including statistical threshold voltage (Vt) variability, endurance, and data retention have been comparatively investigated. It was experimentally found that a larger memory window and a deeper erase are obtained in PVD-TiN-gated metal-oxide-nitride-oxide-silicon (MONOS)-type flash memories than in poly-Si-gated poly-Si-oxide-nitride-oxide-silicon (SONOS)-type memories. The larger memory window and deeper erase of MONOS-type flash memories are contributed by the higher work function of the PVD-TiN metal gate than of the n+-poly-Si gate, which is effective for suppressing electron back tunneling during erase operation. It was also found that the initial Vt roll-off due to the short-channel effect (SCE) is directly related to the memory window roll-off when the gate length (Lg) is scaled down to 46 nm or less.
Kawamura, Iwanari; Fukamizu, Seiji; Miyazawa, Satoshi; Hojo, Rintaro; Ito, Fusahiko; Watanabe, Masazumi; Nishizaki, Mitsuhiro; Sakurada, Harumizu; Hiraoka, Masayasu
2018-02-01
A 58-year-old man with dilated cardiomyopathy was admitted with heart failure. He had a history of two catheter ablation procedures for ventricular tachycardia (VT) originating from the intraventricular septum (IVS). Before dual valve replacement (DVR), he suffered a VT storm. An electrophysiological study revealed an extended low-voltage area at the IVS with the exit of the induced VT at the anterior side. Radiofrequency application was performed at the VT exit as a landmark for surgical cryoablation (SA). During the DVR, SA was performed at the IVS using this landmark. After SA, the patient had no ventricular tachyarrhythmia.
The development of rating of perceived exertion-based tests of physical working capacity.
Mielke, Michelle; Housh, Terry J; Malek, Moh H; Beck, Travis W; Schmidt, Richard J; Johnson, Glen O
2008-01-01
The purpose of the present study was to use ratings of perceived exertion (RPE) from the Borg (6-20) and OMNI-Leg (0-10) scales to determine the Physical Working Capacity at the Borg and OMNI thresholds (PWC(BORG) and PWC(OMNI)). PWC(BORG) and PWC(OMNI) were compared with other fatigue thresholds determined from the measurement of heart rate (the Physical Working Capacity at the Heart Rate Threshold: PWC(HRT)), and oxygen consumption (the Physical Working Capacity at the Oxygen Consumption Threshold, PWC(VO2)), as well as the ventilatory threshold (VT). Fifteen men and women volunteers (mean age +/- SD = 22 +/- 1 years) performed an incremental test to exhaustion on an electronically braked ergometer for the determination of VO2 peak and VT. The subjects also performed 4 randomly ordered workbouts to exhaustion at different power outputs (ranging from 60 to 206W) for the determination of PWC(BORG), PWC(OMNI), PWC(HRT), and PWC(VO2). The results indicated that there were no significant mean differences among the fatigue thresholds: PWC(BORG) (mean +/- SD = 133 +/- 37W; 67 +/- 8% of VO2 peak), PWC(OMNI) (137 +/- 44W; 68 +/- 9% of VO2 peak), PWC(HRT) (135 +/- 36W; 68 +/- 8% of VO2 peak), PWC(VO2) (145 +/- 41W; 72 +/- 7% of VO2 peak) and VT (131 +/- 45W; 66 +/- 8% of VO2 peak). The results of this study indicated that the mathematical model used to estimate PWC(HRT) and PWC(VO2) can be applied to ratings of perceived exertion to determine PWC(BORG) and PWC(OMNI) during cycle ergometry. Salient features of the PWC(BORG) and PWC(OMNI) tests are that they are simple to administer and require the use of only an RPE scale, a stopwatch, and a cycle ergometer. Furthermore, the power outputs at the PWC(BORG) and PWC(OMNI) may be useful to estimate the VT noninvasively and without the need for expired gas analysis.
Hearing thresholds and ventilation tube treatment in children with unilateral cleft lip and palate.
Tengroth, Birgitta; Hederstierna, Christina; Neovius, Erik; Flynn, Traci
2017-06-01
Children with cleft lip and palate have a high prevalence of otitis media with effusion (OME) which is often associated with a fluctuating, conductive hearing loss in the low and mid-frequencies and a risk for permanent hearing loss in the higher frequencies. Although common, there is no consensus on the treatment of OME with ventilation tubes. The aim of this study is to document if the risk for permanent hearing loss and acquired cholesteatoma increases due to treatment with ventilation tubes (VT treatments) during childhood in a group of children with cleft lip and palate. A retrospective medical chart review of 33 children (25 boys and 8 girls) born with unilateral cleft lip and palate (UCLP) was completed. Audiological data (results of hearing sensitivity tests, the total number of hearing tests, and number of VT treatments) were extracted from medical records from when the children were 4-7 and >7-10 years of age. The hearing thresholds in the speech frequencies improved with age (p < 0,05) but a minority of the children continued to present with elevated hearing thresholds in the higher frequencies at >7-10 years of age. There were no significant correlations between number of VT treatments and hearing thresholds at >7-10 years. Four of the 33 children presented with complications: two children exhibited perforations of the ear drum (6.1%) and two children developed unilateral cholesteatoma (6.1%). In the current study, the hearing sensitivity of children with cleft lip and palate improved with age. However, this improvement was not seen in the higher frequencies. Twelve percent of the children experienced complications following VT treatments. Due to these complications, it is recommended that all children with cleft palate should have routine follow-ups by an ENT doctor and audiologist. As part of the routine follow-up care, hearing assessments should be performed before and after VT treatments. Copyright © 2017 Elsevier B.V. All rights reserved.
Objectivity and validity of EMG method in estimating anaerobic threshold.
Kang, S-K; Kim, J; Kwon, M; Eom, H
2014-08-01
The purposes of this study were to verify and compare the performances of anaerobic threshold (AT) point estimates among different filtering intervals (9, 15, 20, 25, 30 s) and to investigate the interrelationships of AT point estimates obtained by ventilatory threshold (VT) and muscle fatigue thresholds using electromyographic (EMG) activity during incremental exercise on a cycle ergometer. 69 untrained male university students, yet pursuing regular exercise voluntarily participated in this study. The incremental exercise protocol was applied with a consistent stepwise increase in power output of 20 watts per minute until exhaustion. AT point was also estimated in the same manner using V-slope program with gas exchange parameters. In general, the estimated values of AT point-time computed by EMG method were more consistent across 5 filtering intervals and demonstrated higher correlations among themselves when compared with those values obtained by VT method. The results found in the present study suggest that the EMG signals could be used as an alternative or a new option in estimating AT point. Also the proposed computing procedure implemented in Matlab for the analysis of EMG signals appeared to be valid and reliable as it produced nearly identical values and high correlations with VT estimates. © Georg Thieme Verlag KG Stuttgart · New York.
Vucetić, Vlatko; Sentija, Davor; Sporis, Goran; Trajković, Nebojsa; Milanović, Zoran
2014-06-01
The purpose of this study was to compare two methods for determination of anaerobic threshold from two different treadmill protocols. Forty-eight Croatian runners of national rank (ten sprinters, fifteen 400-m runners, ten middle distance runners and thirteen long distance runners), mean age 21.7 +/- 5.1 years, participated in the study. They performed two graded maximal exercise tests on a treadmill, a standard ramp treadmill test (T(SR), speed increments of 1 km x h(-1) every 60 seconds) and a fast ramp treadmill test (T(FR), speed increments of 1 km x h(-1) every 30 seconds) to determine and compare the parameters at peak values and at heart rate at the deflection point (HR(DP)) and ventilation threshold (VT). There were no significant differences between protocols (p > 0.05) for peak values of oxygen uptake (VO(2max), 4.48 +/- 0.43 and 4.44 +/- 0.45 L x min(-1)), weight related VO(2max) (62.5 +/- 6.2 and 62.0 +/- 6.0 mL x kg(-1) x min(-1)), pulmonary ventilation (VE(max), 163.1 +/- 18.7 and 161.3 +/- 19.9 L x min(-1)) and heart rate (HR(max), 192.3 +/- 8.5 and 194.4 +/- 8.7 bpm) (T(FR) and T(SR), respectively). Moreover, no significant differences between T(FR) and T(SR) where found for VT and HR(DP) when expressed as VO2 and HR. However, there was a significant effect of ramp slope on running speed at VO(2max) and at the anaerobic threshold (AnT), independent of the method used (VT: 16.0 +/- 2.2 vs 14.9 +/- 2.2 km x h(-1);HR(DP): 16.5 +/- 1.9 vs 14.9 +/- 2.0 km x h(-1) for T(FR) and T(SR) respectively). Linear regression analysis revealed high between-test and between-method correlations for VO2, HR and running speed parameters (r = 0.78-0.89, p < 0.01). The present study has indicated that the VT and HR(DP) for running (VO2, ventilation, and heart rate at VT/HR(DP)) are independent of test protocol, while there is a significant effect of ramp slope on VT and HR(DP) when expressed as running speed. Moreover, this study demonstrates that the point of deflection from linearity of heart rate may be an accurate predictor of the anaerobic threshold in trained runners, independently of the protocol used.
Li, Min; Chang, Shan; Yang, Longjin; Shi, Jingyi; McFarland, Kelli; Yang, Xiao; Moller, Alyssa; Wang, Chunguang; Zou, Xiaoqin; Chi, Chengwu; Cui, Jianmin
2014-02-21
BK channel β subunits (β1-β4) modulate the function of channels formed by slo1 subunits to produce tissue-specific phenotypes. The molecular mechanism of how the homologous β subunits differentially alter BK channel functions and the role of different BK channel functions in various physiologic processes remain unclear. By studying channels expressed in Xenopus laevis oocytes, we show a novel disulfide-cross-linked dimer conopeptide, Vt3.1 that preferentially inhibits BK channels containing the β4 subunit, which is most abundantly expressed in brain and important for neuronal functions. Vt3.1 inhibits the currents by a maximum of 71%, shifts the G-V relation by 45 mV approximately half-saturation concentrations, and alters both open and closed time of single channel activities, indicating that the toxin alters voltage dependence of the channel. Vt3.1 contains basic residues and inhibits voltage-dependent activation by electrostatic interactions with acidic residues in the extracellular loops of the slo1 and β4 subunits. These results suggest a large interaction surface between the slo1 subunit of BK channels and the β4 subunit, providing structural insight into the molecular interactions between slo1 and β4 subunits. The results also suggest that Vt3.1 is an excellent tool for studying β subunit modulation of BK channels and for understanding the physiological roles of BK channels in neurophysiology.
NASA Astrophysics Data System (ADS)
Robert, Hillard; William, Howland; Bryan, Snyder
2002-03-01
Determination of the electrical properties of semiconductor materials and dielectrics is highly desirable since these correlate best to final device performance. The properties of SiO2 and high k dielectrics such as Equivalent Oxide Thickness(EOT), Interface Trap Density(Dit), Oxide Effective Charge(Neff), Flatband Voltage Hysteresis(Delta Vfb), Threshold Voltage(VT) and, bulk properties such as carrier density profile and channel dose are all important parameters that require monitoring during front end processing. Conventional methods for determining these parameters involve the manufacturing of polysilicon or metal gate MOS capacitors and subsequent measurements of capacitance-voltage(CV) and/or current-voltage(IV). These conventional techniques are time consuming and can introduce changes to the materials being monitored. Also, equivalent circuit effects resulting from excessive leakage current, series resistance and stray inductance can introduce large errors in the measured results. In this paper, a new method is discussed that provides rapid determination of these critical parameters and is robust against equivalent circuit errors. This technique uses a small diameter(30 micron), elastically deformed probe to form a gate for MOSCAP CV and IV and can be used to measure either monitor wafers or test areas within scribe lines on product wafers. It allows for measurements of dielectrics thinner than 10 Angstroms. A detailed description and applications such as high k dielectrics, will be presented.
NASA Astrophysics Data System (ADS)
Wang, Fangzhou; Chen, Wanjun; Wang, Zeheng; Sun, Ruize; Wei, Jin; Li, Xuan; Shi, Yijun; Jin, Xiaosheng; Xu, Xiaorui; Chen, Nan; Zhou, Qi; Zhang, Bo
2017-05-01
To achieve uniform low turn-on voltage and high reverse blocking capability, an AlGaN/GaN power field effect rectifier with trench heterojunction anode (THA-FER) is proposed and investigated in this work which includes only simulated data and no real experimental result. VT has a low saturation value when trench height (HT) is beyond 300 nm, confirming it is possible to control the VT accurately without precisely controlling the HT in the THA-FER. Meanwhile, high HT anode reduces reverse leakage current and yields high breakdown voltage (VB). A superior high Baliga's Figure of Merits (BFOM = VB2/Ron,sp, Ron,sp is specific-on resistance) of 1228 MW/cm2 reveals the THA-FER caters for the demands of high efficiency GaN power applications.
NASA Astrophysics Data System (ADS)
Jung, Haesun; Choi, Sungju; Jang, Jun Tae; Yoon, Jinsu; Lee, Juhee; Lee, Yongwoo; Rhee, Jihyun; Ahn, Geumho; Yu, Hye Ri; Kim, Dong Myong; Choi, Sung-Jin; Kim, Dae Hwan
2018-02-01
We propose a universal model for bias-stress (BS)-induced instability in the inkjet-printed carbon nanotube (CNT) networks used in field-effect transistors (FETs). By combining two experimental methods, i.e., a comparison between air and vacuum BS tests and interface trap extraction, BS instability is explained regardless of either the BS polarity or ambient condition, using a single platform constituted by four key factors: OH- adsorption/desorption followed by a change in carrier concentration, electron concentration in CNT channel corroborated with H2O/O2 molecules in ambient, charge trapping/detrapping, and interface trap generation. Under negative BS (NBS), the negative threshold voltage shift (ΔVT) is dominated by OH- desorption, which is followed by hole trapping in the interface and/or gate insulator. Under positive BS (PBS), the positive ΔVT is dominated by OH- adsorption, which is followed by electron trapping in the interface and/or gate insulator. This instability is compensated by interface trap extraction; PBS instability is slightly more complicated than NBS instability. Furthermore, our model is verified using device simulation, which gives insights on how much each mechanism contributes to BS instability. Our result is potentially useful for the design of highly stable CNT-based flexible circuits in the Internet of Things wearable healthcare era.
Smith, Darren A; Saranga, Jacob; Pritchard, Andrew; Kommatas, Nikolaos A; Punnoose, Shinu Kovelal; Kale, Supriya Tukaram
2018-01-01
Mulligan's mobilisation-with-movement (MWM) techniques are proposed to achieve their clinical benefit via neurophysiological mechanisms. However, previous research has focussed on responses in the sympathetic nervous system only, and is not conclusive. An alternative measure of neurophysiological response to MWM is required to support or refute this mechanism of action. Recently, vibration threshold (VT) has been used to quantify changes in the sensory nervous system in patients experiencing musculoskeletal pain. To investigate the effect of a lateral glide MWM of the hip joint on vibration threshold compared to a placebo and control condition in asymptomatic volunteers. Fifteen asymptomatic volunteers participated in this single-blinded, randomised, within-subject, placebo, control design. Participants received each of three interventions in a randomised order; a lateral glide MWM of the hip joint into flexion, a placebo MWM, and a control intervention. Vibration threshold (VT) measures were taken at baseline and immediately after each intervention. Mean change in VT from baseline was calculated for each intervention and then analysed for between group differences using a one-way analysis of variance (ANOVA). A one-way ANOVA revealed no statistically significant differences between the three experimental conditions (P = 0.812). This small study found that a lateral glide MWM of the hip did not significantly change vibration threshold compared to a placebo and control intervention in an asymptomatic population. This study provides a method of using vibration threshold to investigate the potential neurophysiological effects of a manual therapy intervention that should be repeated in a larger, symptomatic population. Copyright © 2016 Elsevier Ltd. All rights reserved.
Greer, Beau Kjerulf; Katalinas, Matthew E; Shaholli, Danielle M; Gallo, Paul M
2016-01-01
The purpose of the present study was to determine the effect of 30 days of β-alanine supplementation on peak aerobic power and ventilatory threshold (VT) in aerobically fit males. Fourteen males (28.8 ± 9.8 yrs) were assigned to either a β-alanine (SUPP) or placebo (PLAC) group; groups were matched for VT as it was the primary outcome measure. β-alanine supplementation consisted of 3 g/day for 7 days, and 6 g/day for the remaining 23 days. Before and after the supplementation period, subjects performed a continuous, graded cycle ergometry test to determine VO2 peak and VT. Metabolic data were analyzed using a 2 × 2 ANOVA with repeated measures. Thirty days of β-alanine supplementation (SUPP) did not increase VO2 peak (4.05 ± 0.6 vs. 4.14 ± 0.6 L/min) as compared to the placebo (PLAC) group (3.88 ± 0.2 vs. 3.97 ± 0.2 L/min) (p > .05). VT did not significantly improve in either the SUPP (3.21 ± 0.5 vs. 3.33 ± 0.5 L/min) or PLAC (3.19 ± 0.1 vs. 3.20 ± 0.1 L/min) group (p > .05). In conclusion, 30 days of β-alanine supplementation had no effect on VO2 peak or VT in aerobically trained athletes.
Boyne, Pierce; Reisman, Darcy; Brian, Michael; Barney, Brian; Franke, Ava; Carl, Daniel; Khoury, Jane; Dunning, Kari
2017-03-01
After stroke, aerobic deconditioning can have a profound impact on daily activities. This is usually measured by the peak oxygen consumption rate achieved during exercise testing (VO2-peak). However, VO2-peak may be distorted by motor function. The oxygen uptake efficiency slope (OUES) and VO2 at the ventilatory threshold (VO2-VT) could more specifically assess aerobic capacity after stroke, but this has not been tested. To assess the differential influence of motor function on three measures of aerobic capacity (VO2-peak, OUES, and VO2-VT) and to evaluate the inter-rater reliability of VO2-VT determination post-stroke. Among 59 persons with chronic stroke, cross-sectional correlations with motor function (comfortable gait speed [CGS] and lower extremity Fugl-Meyer [LEFM]) were compared between the different aerobic capacity measures, after adjustment for covariates, in order to isolate any distorting effect of motor function. Reliability of VO2-VT determination between three raters was assessed with intra-class correlation (ICC). CGS was moderately correlated with VO2-peak (r = 0.52, p < 0.0001) and weakly correlated with OUES (r = 0.41, p = 0.002) and VO2-VT (r = 0.37, p = 0.01). LEFM was weakly correlated with VO2-peak (r = 0.26, p = 0.055) and very weakly correlated with OUES (r = 0.19, p = 0.17) and VO2-VT (r = 0.14, p = 0.31). Compared to VO2-peak, VO2-VT was significantly less correlated with CGS (r difference = -0.16, p = 0.02). Inter-rater reliability of VO2-VT determination was high (ICC: 0.93, 95% CI: 0.89-0.96). Motor dysfunction appears to artificially lower measured aerobic capacity. VO2-VT seemed to be less distorted than VO2-peak and had good inter-rater reliability, so it may provide more specific assessment of aerobic capacity post-stroke.
Fornasiero, Alessandro; Savoldelli, Aldo; Fruet, Damiano; Boccia, Gennaro; Pellegrini, Barbara; Schena, Federico
2018-06-01
The aims of the study were to describe the physiological profile of a 65-km (4000-m cumulative elevation gain) running mountain ultra-marathon (MUM) and to identify predictors of MUM performance. Twenty-three amateur trail-runners performed anthropometric evaluations and an uphill graded exercise test (GXT) for VO 2max, ventilatory thresholds (VTs), power outputs (PMax, PVTs) and heart rate response (HRmax, HR@VTs). Heart rate (HR) was monitored during the race and intensity was expressed as: Zone I (
Zhang, Jian-Guo; Ohta, Toshiki; Ishikawa-Takata, Kazuko; Tabata, Izumi; Miyashita, Mitsumasa
2003-09-01
The relationships among walk steps, exercise habits and peak oxygen consumption (VO2peak), ventilatory threshold (VT) and leg extension power (LEP) were examined in 709 apparently healthy Japanese subjects (male 372, female 337) aged 30-69 years. Walk steps were evaluated using a pedometer. VO2peak and VT were assessed by a cycle ergometer test, while LEP was measured with an isokinetic leg extension system (Combi, Anaero Press 3500, Japan). Subjects who participated in exercise three times or more a week demonstrated significantly greater VO2peak and VT when compared with subjects without exercise habits. When a separate analysis was conducted on subjects who exercised fewer than three times per week, we found that the subgroup with the highest number of walk steps showed significantly greater VT in all male subjects and female subjects aged 30-49 years, but a significantly greater VO2peak only in females aged 30-49 years, when compared to the subgroup with the fewest walk steps. These results suggest that although some people exercise less than three times a week, if they are quite active in daily life, such activities might also confer benefits upon their fitness.
Gökoğlan, Yalçın; Mohanty, Sanghamitra; Gianni, Carola; Santangeli, Pasquale; Trivedi, Chintan; Güneş, Mahmut F; Bai, Rong; Al-Ahmad, Amin; Gallinghouse, G Joseph; Horton, Rodney; Hranitzky, Patrick M; Sanchez, Javier E; Beheiry, Salwa; Hongo, Richard; Lakkireddy, Dhanunjaya; Reddy, Madhu; Schweikert, Robert A; Dello Russo, Antonio; Casella, Michela; Tondo, Claudio; Burkhardt, J David; Themistoclakis, Sakis; Di Biase, Luigi; Natale, Andrea
2016-11-01
Scar homogenization improves long-term ventricular arrhythmia-free survival compared with standard limited-substrate ablation in patients with post-infarction ventricular tachycardia (VT). Whether such benefit extends to patients with nonischemic cardiomyopathy and scar-related VT is unclear. The aim of this study was to assess the long-term efficacy of an endoepicardial scar homogenization approach compared with standard ablation in this population. Consecutive patients with dilated nonischemic cardiomyopathy (n = 93), scar-related VTs, and evidence of low-voltage regions on the basis of pre-defined criteria on electroanatomic mapping (i.e., bipolar voltage <1.5 mV) underwent either standard VT ablation (group 1 [n = 57]) or endoepicardial ablation of all abnormal potentials within the electroanatomic scar (group 2 [n = 36]). Acute procedural success was defined as noninducibility of any VT at the end of the procedure; long-term success was defined as freedom from any ventricular arrhythmia at follow-up. Acute procedural success rates were 69.4% and 42.1% after scar homogenization and standard ablation, respectively (p = 0.01). During a mean follow-up period of 14 ± 2 months, single-procedure success rates were 63.9% after scar homogenization and 38.6% after standard ablation (p = 0.031). After multivariate analysis, scar homogenization and left ventricular ejection fraction were predictors of long-term success. During follow-up, the rehospitalization rate was significantly lower in the scar homogenization group (p = 0.035). In patients with dilated nonischemic cardiomyopathy, scar-related VT, and evidence of low-voltage regions on electroanatomic mapping, endoepicardial homogenization of the scar significantly increased freedom from any recurrent ventricular arrhythmia compared with a standard limited-substrate ablation. However, the success rate with this approach appeared to be lower than previously reported with ischemic cardiomyopathy, presumably because of the septal and midmyocardial distribution of the scar in some patients. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Peddareddy, Lakshmi; Merchant, Faisal M; Leon, Angel R; Smith, Paige; Patel, Akshar; El-Chami, Mikhael F
2018-06-12
Defibrillation threshold (DFT) testing is recommended with the subcutaneous ICD (SICD). To describe first shock efficacy for appropriate SICD therapies stratified by the presence of implant DFT testing. We reviewed all patients receiving SICDs at our institution and stratified them based on whether implant DFT testing was performed. Appropriate shocks were reviewed to see if ventricular tachycardia/ventricular fibrillation (VT/VF) terminated with a single shock. First shock efficacy was stratified by implant DFT status. 178 patients implanted with SICDs and followed in our center were included in this study. Of these, 135 (76 %) underwent DFT testing (DFT (+) group). In the DFT (+) 80 appropriate shocks were needed to treat 69 episodes of VT/VF. The first shock was effective in 61 out of 69 episodes (88.4 %), whereas multiple shocks were required to terminate VT/VF in the remaining 8 episodes. Among 43 patients without implant DFT testing (DFT (-) group), 20 appropriate shocks to treat 17 episodes of VT/VF occurred in 7 patients. VT/VF was successfully terminated with the first shock in 16 out of 17 episodes (first shock efficacy 94.1 %). There was no significant difference in first shock effectiveness between those with and without implant DFT testing (p = 0.97). A strategy that omits DFT testing at implant did not appear to compromise the effictiveness of the SICD. These data suggest that routine DFT testing at SICD implant might not be necessary. Randomized trials are needed to confirm this finding. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
EDGE2D-EIRENE modelling of near SOL E r: possible impact on the H-mode power threshold
NASA Astrophysics Data System (ADS)
Chankin, A. V.; Delabie, E.; Corrigan, G.; Harting, D.; Maggi, C. F.; Meyer, H.; Contributors, JET
2017-04-01
Recent EDGE2D-EIRENE simulations of JET plasmas showed a significant difference between radial electric field (E r) profiles across the separatrix in two divertor configurations, with the outer strike point on the horizontal target (HT) and vertical target (VT) (Chankin et al 2016 Nucl. Mater. Energy, doi: 10.1016/j.nme.2016.10.004). Under conditions (input power, plasma density) where the HT plasma went into the H-mode, a large positive E r spike in the near scrape-off layer (SOL) was seen in the code output, leading to a very large E × B shear across the separatrix over a narrow region of a fraction of a cm width. No such E r feature was obtained in the code solution for the VT configuration, where the H-mode power threshold was found to be twice as high as in the HT configuration. It was hypothesised that the large E × B shear across the separatrix in the HT configuration could be responsible for the turbulence suppression leading to an earlier (at lower input power) L-H transition compared to the VT configuration. In the present work these ideas are extended to cover some other experimental observations on the H-mode power threshold variation with parameters which typically are not included in the multi-machine H-mode power threshold scalings, namely: ion mass dependence (isotope H-D-T exchange), dependence on the ion ∇B drift direction, and dependence on the wall material composition (ITER-like wall versus carbon wall in JET). In all these cases EDGE2D-EIRENE modelling shows larger positive E r spikes in the near SOL under conditions where the H-mode power threshold is lower, at least in the HT configuration.
Timing discriminator using leading-edge extrapolation
Gottschalk, Bernard
1983-01-01
A discriminator circuit to recover timing information from slow-rising pulses by means of an output trailing edge, a fixed time after the starting corner of the input pulse, which is nearly independent of risetime and threshold setting. This apparatus comprises means for comparing pulses with a threshold voltage; a capacitor to be charged at a certain rate when the input signal is one-third threshold voltage, and at a lower rate when the input signal is two-thirds threshold voltage; current-generating means for charging the capacitor; means for comparing voltage capacitor with a bias voltage; a flip-flop to be set when the input pulse reaches threshold voltage and reset when capacitor voltage reaches the bias voltage; and a clamping means for discharging the capacitor when the input signal returns below one-third threshold voltage.
Grimm, W; Menz, V; Hoffmann, J; Maisch, B
1998-04-01
Unnecessary shocks by ICDs for rhythms other than sustained VT or VF have been described as the most frequent adverse event in ICD patients. To avoid unnecessary shocks for self-terminating arrhythmias, the third-generation Jewel PCD defibrillators 7202, 7219, and 7220 Plus use a specially designed VF confirmation algorithm after charge end. The purpose of this study was to determine the ability of this VF confirmation algorithm to recognize nonsustained VT, and to analyze the reasons for failure of the PCD device to abort shock therapy for nonsustained VT despite use of this VF confirmation algorithm. Analysis of stored electrograms of electrical events triggering high voltage capacitor charging in the programmed VF zone of the device showed 36 spontaneous episodes of nonsustained VT (227 +/- 21 beats/min) during 18 +/- 7 months follow-up in 15 patients who had a Jewel PCD implanted at our hospital. Intracardiac electrogram recordings and simultaneously retrieved marker channels demonstrated that the ICD shock was appropriately aborted according to the VF confirmation algorithm in 24 (67%) of 36 episodes of nonsustained VT. Twelve episodes (33%) of nonsustained VT, however, were followed by spontaneous ICD shock in 6 (40%) of the 15 study patients. The only reason for all 12 shocks for sustained VT was the inability of the device to recognize the absence of VT after charge end due to shortcomings of the VF confirmation algorithm: 11 of the 12 shocks for nonsustained VT were triggered by the occurrence of paced beats during the VF confirmation period and 1 shock for nonsustained VT was triggered by the occurrence of 2 premature beats after charge end. Thus, better VF confirmation algorithms need to be incorporated in future PCD devices to avoid unnecessary shocks for nonsustained VT.
ONR Far East Scientific Bulletin. Volume 11, Number 2.
1986-06-01
the following subjects: the consequences of increasing CO 2 in the atmosphere, the exchange rate of chemical substances between the ocean and the...characteristics for emitter-common at 77 K is shown. The current amplication factor Bof 3.8 was obtained. This is expected to increase further by reduction of the...mS/V mm. The gate sustaining voltage (-BVGD) is seen to decrease as the n’ dose is increased . ’ ith L =0.8 um devices, Gm=250 mS/mm, VT=O.l V and aVT
Timing discriminator using leading-edge extrapolation
Gottschalk, B.
1981-07-30
A discriminator circuit to recover timing information from slow-rising pulses by means of an output trailing edge, a fixed time after the starting corner of the input pulse, which is nearly independent of risetime and threshold setting is described. This apparatus comprises means for comparing pulses with a threshold voltage; a capacitor to be charged at a certain rate when the input signal is one-third threshold voltage, and at a lower rate when the input signal is two-thirds threshold voltage; current-generating means for charging the capacitor; means for comparing voltage capacitor with a bias voltage; a flip-flop to be set when the input pulse reaches threshold voltage and reset when capacitor voltage reaches the bias voltage; and a clamping means for discharging the capacitor when the input signal returns below one-third threshold voltage.
NASA Astrophysics Data System (ADS)
Sosnowski, M.; Eager, G. S., Jr.
1983-06-01
Threshold voltage of oil-impregnated paper insulated cables are investigaed. Experimental work was done on model cables specially manufactured for this project. The cables were impregnated with mineral and with synthetic oils. Standard impulse breakdown voltage tests and impulse voltage breakdown tests with dc prestressing were performed at room temperature and at 1000C. The most important result is the finding of very high level of threshold voltage stress for oil-impregnated paper insulated cables. This threshold voltage is approximately 1.5 times higher than the threshold voltage or crosslinked polyethylene insulated cables.
NASA Astrophysics Data System (ADS)
Kishimoto, Jessica; Fenster, Aaron; Salehi, Fateme; Romano, Walter; Lee, David S. C.; de Ribaupierre, Sandrine
2016-04-01
Dilation of the cerebral ventricles is a common condition in preterm neonates with intraventricular hemorrhage (IVH). This post hemorrhagic ventricle dilation (PHVD) can lead to lifelong neurological impairment through ischemic injury due to increased intracranial pressure and without treatment, can lead to death. Clinically, 2D ultrasound (US) through the fontanelles ('soft spots') of the patients are serially acquired to monitor the progression of the ventricle dilation. These images are used to determine when interventional therapies such as needle aspiration of the built up cerebrospinal fluid (CSF) ('ventricle tap', VT) might be indicated for a patient; however, quantitative measurements of the growth of the ventricles are often not performed. There is no consensus on when a neonate with PHVD should have an intervention and often interventions are performed after the potential for brain damage is quite high. Previously we have developed and validated a 3D US system to monitor the progression of ventricle volumes (VV) in IVH patients. We will describe the potential utility of quantitative 2D and 3D US to monitor and manage PHVD in neonates. Specifically, we will look to determine image-based measurement thresholds for patients who will require VT in comparison to patients with PHVD who resolve without intervention. Additionally, since many patients who have an initial VT will require subsequent interventions, we look at the potential for US to determine which PHVD patients will require additional VT after the initial one has been performed.
NASA Astrophysics Data System (ADS)
Wang, S.; Mirkhani, V.; Yapabandara, K.; Cheng, R.; Hernandez, G.; Khanal, M. P.; Sultan, M. S.; Uprety, S.; Shen, L.; Zou, S.; Xu, P.; Ellis, C. D.; Sellers, J. A.; Hamilton, M. C.; Niu, G.; Sk, M. H.; Park, M.
2018-04-01
We report on the fabrication and electrical characterization of bottom gate thin-film transistors (TFTs) based on a sol-gel derived ZnO channel layer. The effect of annealing of ZnO active channel layers on the electrical characteristics of the ZnO TFTs was systematically investigated. Photoluminescence (PL) spectra indicate that the crystal quality of the ZnO improves with increasing annealing temperature. Both the device turn-on voltage (Von) and threshold voltage (VT) shift to a positive voltage with increasing annealing temperature. As the annealing temperature is increased, both the subthreshold slope and the interfacial defect density (Dit) decrease. The field effect mobility (μFET) increases with annealing temperature, peaking at 800 °C and decreases upon further temperature increase. An improvement in transfer and output characteristics was observed with increasing annealing temperature. However, when the annealing temperature reaches 900 °C, the TFTs demonstrate a large degradation in both transfer and output characteristics, which is possibly produced by non-continuous coverage of the film. By using the temperature-dependent field effect measurements, the localized sub-gap density of states (DOSs) for ZnO TFTs with different annealing temperatures were determined. The DOSs for the subthreshold regime decrease with increasing annealing temperature from 600 °C to 800 °C and no substantial change was observed with further temperature increase to 900 °C.
Evolution of Multiple Double Layer in Glow discharge and its inherent Properties
NASA Astrophysics Data System (ADS)
Alex, Prince; A, Saravanan; Sinha, Suraj
2016-10-01
Formation and evolution of multiple anodic double layers (MADLs) were experimentally studied in glow discharge plasma. The boundary condition for the existence of MADL was identified in terms of threshold bias and ambient working pressure. The MADL formation is accompanied by an explosive growth in anode current and consequent current-voltage characteristics follows a hysteresis loop. The analysis yield that stable MADLs is only observed when the control voltage V2 is between a certain critical values (Vq
Alkhatib, Ahmad
2015-01-01
Sedentariness and physical inactivity are often reported within white-collar workers, including university campus employees. However, the prevalence of the associated sedentary risk factors and risk reduction intervention strategies within a university campus workplace are less known. This study investigates whether the prevalence of sedentary risk factors within university campus employees could be reduced with a campus based exercise intervention. 56 UK university employees (age = 50.7 ± 10.2, stature = 1.68.8 ± 8.6, body mass = 73.9 ± 15.1) were tested for body mass index (BMI), systolic blood pressure (SBP), diastolic blood pressure (DBP) and maximal cardiorespiratory capacity (V̇O2max). The prevalence was analyzed across genders and job roles. An exercise intervention followed for the sedentary employees involving walking and running for 25 min twice/week for 10 weeks at an intensity corresponding to individual's ventilatory threshold (VT). The university workplace demonstrated a prevalence of higher BMI, SBP and DBP than the recommended healthy thresholds, with gender having a significant effect. Males' BMI, SBP and DBP were higher than in females (p < 0.05) and males' V̇O2max was lower than the recommended healthy thresholds. The exercise training intervention significantly improved V̇O2max, VT and VT velocity in both genders (all p < 0.05) with both groups meeting the recommended thresholds following the intervention. University campus employees have a high prevalence of sedentary risk factors across different genders and job roles. These risks can be reduced by an exercise-based intervention administered within the campus workplace, which should be considered in university workplace policies.
Optimum Design of Millimeter-Wave Impatt Diode Oscillators.
1983-10-01
assumed to be a quasi-sinusoid of the form v(t) a Vej"t (2.1) where V = V(t) and w = w(t) are real slowly varying functions of time . Slowly varying can be...are used: i dVF = 1 HF (3.12) RF dt 4 and 6 = w- i. (3.13) Therefore, the RF voltage and phase at different times can be calculated: VRF(t + dt ) = VF...15 2.2.2 The Circuit Model 18 2.2.3 Thermal Resistance 21 2.2.4 Thermal- Time Constant 23 2.3 Usefulness and Limitations of the Oscillator Model 26
Martini, Bortolo; Trevisi, Nicola; Martini, Nicolò; Zhang, Li
2015-01-01
A 43-year-old woman presented to the emergency room with a sustained ventricular tachycardia (VT). ECG showed a QRS in left bundle branch block morphology with inferior axis. Echocardiography, ventricular angiography, and cardiac magnetic resonance imaging (CMRI) revealed a normal right ventricle and a left ventricular diverticulum. Electrophysiology studies with epicardial voltage mapping identified a large fibrotic area in the inferolateral layer of the right ventricular wall and a small area of fibrotic tissue at the anterior right ventricular outflow tract. VT ablation was successfully performed with combined epicardial and endocardial approaches.
Martini, Bortolo; Trevisi, Nicola; Martini, Nicolò; Zhang, Li
2015-01-01
A 43-year-old woman presented to the emergency room with a sustained ventricular tachycardia (VT). ECG showed a QRS in left bundle branch block morphology with inferior axis. Echocardiography, ventricular angiography, and cardiac magnetic resonance imaging (CMRI) revealed a normal right ventricle and a left ventricular diverticulum. Electrophysiology studies with epicardial voltage mapping identified a large fibrotic area in the inferolateral layer of the right ventricular wall and a small area of fibrotic tissue at the anterior right ventricular outflow tract. VT ablation was successfully performed with combined epicardial and endocardial approaches. PMID:26509086
A multi-GHz chaotic optoelectronic oscillator based on laser terminal voltage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, C. Y., E-mail: cychang@gatech.edu; UMI 2958 Georgia Tech-CNRS, Georgia Tech Lorraine, 2 Rue Marconi, F-57070 Metz; Choi, Daeyoung
2016-05-09
A multi-GHz chaotic optoelectronic oscillator based on an external cavity semiconductor laser (ECL) is demonstrated. Unlike the standard optoelectronic oscillators for microwave applications, we do not employ the dynamic light output incident on a photodiode to generate the microwave signal, but instead generate the microwave signal directly by measuring the terminal voltage V(t) of the laser diode of the ECL under constant-current operation, thus obviating the photodiode entirely.
NASA Technical Reports Server (NTRS)
Burns, Bradley M. (Inventor); Blalock, Norman N. (Inventor)
2011-01-01
A short circuit protection system includes an inductor, a switch, a voltage sensing circuit, and a controller. The switch and inductor are electrically coupled to be in series with one another. A voltage sensing circuit is coupled across the switch and the inductor. A controller, coupled to the voltage sensing circuit and the switch, opens the switch when a voltage at the output terminal of the inductor transitions from above a threshold voltage to below the threshold voltage. The controller closes the switch when the voltage at the output terminal of the inductor transitions from below the threshold voltage to above the threshold voltage.
Studies on fully transparent Al-Sn-Zn-O thin-film transistors fabricated on glass at low temperature
NASA Astrophysics Data System (ADS)
Cong, Yingying; Han, Dedong; Wu, Jing; Zhao, Nannan; Chen, Zhuofa; Zhao, Feilong; Dong, Junchen; Zhang, Shengdong; Zhang, Xing; Wang, Yi
2015-04-01
High-performance fully transparent Al-Sn-Zn-O thin-film transistors (ATZO TFTs) with excellent electrical performance have been successfully fabricated by RF magnetron sputtering on glass at low temperatures. Two kinds of appropriate ATZO compositions are compared from several perspectives, including film material characteristics, device electrical performances, and fabrication process conditions. Finally, we achieve two excellent ATZO TFTs with competitive advantages. The ATZO TFT with larger amounts of dopants exhibits a superior field effect mobility μFE of 102.38 cm2 V-1 s-1, an ON/OFF current ratio (Ion/Ioff) of 1.18 × 107, and a threshold voltage VT of 1.35 V. The device with smaller amounts of dopants demonstrates better crystal quality and an excellent subthreshold swing SS of 155 mV/dec. Furthermore, it is less affected by oxygen partial pressure. The ATZO thin films display a high transmittance of over 80% in the visible light range.
Effects of ultra-thin Si-fin body widths upon SOI PMOS FinFETs
NASA Astrophysics Data System (ADS)
Liaw, Yue-Gie; Chen, Chii-Wen; Liao, Wen-Shiang; Wang, Mu-Chun; Zou, Xuecheng
2018-05-01
Nano-node tri-gate FinFET devices have been developed after integrating a 14 Å nitrided gate oxide upon the silicon-on-insulator (SOI) wafers established on an advanced CMOS logic platform. These vertical double gate (FinFET) devices with ultra-thin silicon fin (Si-fin) widths ranging from 27 nm to 17 nm and gate length down to 30 nm have been successfully developed with a 193 nm scanner lithography tool. Combining the cobalt fully silicidation and the CESL strain technology beneficial for PMOS FinFETs was incorporated into this work. Detailed analyses of Id-Vg characteristics, threshold voltage (Vt), and drain-induced barrier lowering (DIBL) illustrate that the thinnest 17 nm Si-fin width FinFET exhibits the best gate controllability due to its better suppression of short channel effect (SCE). However, higher source/drain resistance (RSD), channel mobility degradation due to dry etch steps, or “current crowding effect” will slightly limit its transconductance (Gm) and drive current.
Smith, Ashleigh E; Eston, Roger; Tempest, Gavin D; Norton, Belinda; Parfitt, Gaynor
2015-09-01
The American College of Sports Medicine has highlighted the importance of considering the physiological and affective responses to exercise when setting exercise intensity. Here, we examined the relationship between exercise intensity and physiological and affective responses in active older adults. Eighteen participants (60-74 years; 64.4 ± 3.9; 8 women) completed a maximal graded exercise test (GXT) on a treadmill. Since time to exhaustion in the GXT differed between participants, heart rate (HR), oxygen consumption (VO2), affective valence (affect) and rating of perceived exertion (RPE) were expressed relative to the individually determined ventilatory threshold (%atVT). During the GXT, VO2, HR and RPE increased linearly (all P < 0.01). Affect declined initially (but remained positive) (P = 0.03), stabilised around VT (still positive) (P > 0.05) and became negative towards the end of the test (P < 0.01). In a subsequent session, participants completed a 20-min bout of self-selected exercise (at a preferred intensity). Initially, participants chose to exercise below VT (88.2 ± 17.4 %VO2atVT); however, the intensity was adjusted to work at, or above VT (107.7 ± 19.9 %VO2atVT) after 10 min (P < 0.001), whilst affect remained positive. Together, these findings indicate that exercise around VT, whether administered during an exercise test, or self-selected by the participant, is likely to result in positive affective responses in older adults.
Synthesis of polymer nanostructures with conductance switching properties
Su, Kai; Nuraje, Nurxat; Zhang, Lingzhi; Matsui, Hiroshi; Yang, Nan Loh
2015-03-03
The present invention is directed to crystalline organic polymer nanoparticles comprising a conductive organic polymer; wherein the crystalline organic polymer nanoparticles have a size of from 10 nm to 200 nm and exhibits two current-voltage states: (1) a high resistance current-voltage state, and (2) a low resistance current-voltage state, wherein when a first positive threshold voltage (V.sub.th1) or higher positive voltage, or a second negative threshold voltage (V.sub.th2) or higher negative voltage is applied to the nanoparticle, the nanoparticle exhibits the low-resistance current-voltage state, and when a voltage less positive than the first positive threshold voltage or a voltage less negative than the second negative threshold voltage is applied to the nanoparticle, the nanoparticle exhibits the high-resistance current-voltage state. The present invention is also directed methods of manufacturing the nanoparticles using novel interfacial oxidative polymerization techniques.
Corona-vacuum failure mechanism test facilities
NASA Technical Reports Server (NTRS)
Lalli, V. R.; Mueller, L. A.; Koutnik, E. A.
1975-01-01
A nondestructive corona-vacuum test facility for testing high-voltage power system components has been developed using commercially available hardware. The facility simulates operating temperature and vacuum while monitoring coronal discharges with residual gases. Corona threshold voltages obtained from statorette tests with various gas-solid dielectric systems and comparison with calculated data support the following conclusions: (1) air gives the highest corona threshold voltage and helium the lowest, with argon and helium-xenon mixtures intermediate; (2) corona threshold voltage increases with gas pressure; (3) corona threshold voltage for an armature winding can be accurately calculated by using Paschen curves for a uniform field; and (4) Paschen curves for argon can be used to calculate the corona threshold voltage in He-Xe mixtures, for which Paschen curves are unavailable.-
NASA Astrophysics Data System (ADS)
Oh, Kyonghwan; Kwon, Oh-Kyong
2012-03-01
A threshold-voltage-shift compensation and suppression method for active matrix organic light-emitting diode (AMOLED) displays fabricated using a hydrogenated amorphous silicon thin-film transistor (TFT) backplane is proposed. The proposed method compensates for the threshold voltage variation of TFTs due to different threshold voltage shifts during emission time and extends the lifetime of the AMOLED panel. Measurement results show that the error range of emission current is from -1.1 to +1.7% when the threshold voltage of TFTs varies from 1.2 to 3.0 V.
NASA Astrophysics Data System (ADS)
Choi, Woo Young; Woo, Dong-Soo; Choi, Byung Yong; Lee, Jong Duk; Park, Byung-Gook
2004-04-01
We proposed a stable extraction algorithm for threshold voltage using transconductance change method by optimizing node interval. With the algorithm, noise-free gm2 (=dgm/dVGS) profiles can be extracted within one-percent error, which leads to more physically-meaningful threshold voltage calculation by the transconductance change method. The extracted threshold voltage predicts the gate-to-source voltage at which the surface potential is within kT/q of φs=2φf+VSB. Our algorithm makes the transconductance change method more practical by overcoming noise problem. This threshold voltage extraction algorithm yields the threshold roll-off behavior of nanoscale metal oxide semiconductor field effect transistor (MOSFETs) accurately and makes it possible to calculate the surface potential φs at any other point on the drain-to-source current (IDS) versus gate-to-source voltage (VGS) curve. It will provide us with a useful analysis tool in the field of device modeling, simulation and characterization.
Rodríguez-Marroyo, J A; Villa, J G; López-Satue, J; Pernía, R; Carballo, B; García-López, J; Foster, C
2011-11-01
The aim of this study was to analyse the physiological strain of firefighters, using heart rate (HR) and core temperature, during real wildfire suppression according to the type of attack performed (direct, indirect or mixed). Three intensity zones were established according to the HR corresponding to the ventilatory threshold (VT) and respiratory compensation threshold (RCT): zone 1,
Identification of spinal circuits involved in touch-evoked dynamic mechanical pain
Cheng, Longzhen; Duan, Bo; Huang, Tianwen; Zhang, Yan; Chen, Yangyang; Britz, Olivier; Garcia-Campmany, Lidia; Ren, Xiangyu; Vong, Linh; Lowell, Bradford B.; Goulding, Martyn; Wang, Yun; Ma, Qiufu
2017-01-01
Mechanical hypersensitivity is a debilitating symptom associated with millions of chronic pain patients. It exists in distinct forms, including brush-evoked dynamic and filament-evoked punctate. Here we report that dynamic mechanical hypersensitivity induced by nerve injury or inflammation was compromised in mice with ablation of spinal VT3Lbx1 neurons defined by coexpression of VGLUT3Cre and Lbx1Flpo, as indicated by the loss of brush-evoked nocifensive responses and conditional place aversion. Electrophysiological recordings show that VT3Lbx1 neurons form morphine-resistant polysynaptic pathways relaying inputs from low-threshold Aβ mechanoreceptors to lamina I output neurons. Meanwhile, the subset of somatostatin (SOM) lineage neurons preserved in VT3Lbx1 neuron-ablated mice is largely sufficient to mediate von Frey filament-evoked punctate mechanical hypersensitivity, including both morphine-sensitive and morphine-resistant forms. Furthermore, acute silencing of VT3Lbx1 neurons attenuated pre-established dynamic mechanical hypersensitivity induced by nerve injury, suggesting these neurons as a potential cellular target for treating this form of neuropathic pain. PMID:28436981
NASA Astrophysics Data System (ADS)
Ono, Ryo; Teramoto, Yoshiyuki; Nakagawa, Yusuke; Komuro, Atsushi; Oda, Tetsuji
2011-10-01
Translational and vibrational temperatures are measured in pulsed corona discharge using spatiotemporally resolved laser-induced fluorescence (LIF) and coherent anti-Stokes Raman scattering (CARS). The discharge occurs in a 13-mm point-to-plane gap with pulsed voltage of approximately 30 kV. Immediately after the discharge pulse, the vibrational temperatures of N2(v) and O2(v), Tv, are much higher than the translational temperature, Tt. Then, after the discharge pulse, Tv decreases with time, and the energy released from the vibrational relaxation increases Tt. This vibration-to-translation (V-T) energy transfer is observed; Tv and Tt change by hundreds to a thousand K after the discharge pulse with time constants of 1 us to 1 ms. It is shown that the V-T rate is remarkably increased when the ambient air is humidified. It is caused by extremely rapid V-T process of H2O-H2O system. In addition, V-T acceleration of O2(v) by O atoms due to rapid V-T rate of O2(v)-O system is also measured. The spatial profile of Tv shows that Tv decreases with increasing distance from the tip of needle electrode. It indicates that Tv, and the resulting Tt, are higher in the secondary streamer channel than in the primary streamer channel.
Aghamohammadi, Mahdieh; Rödel, Reinhold; Zschieschang, Ute; Ocal, Carmen; Boschker, Hans; Weitz, R Thomas; Barrena, Esther; Klauk, Hagen
2015-10-21
The mechanisms behind the threshold-voltage shift in organic transistors due to functionalizing of the gate dielectric with self-assembled monolayers (SAMs) are still under debate. We address the mechanisms by which SAMs determine the threshold voltage, by analyzing whether the threshold voltage depends on the gate-dielectric capacitance. We have investigated transistors based on five oxide thicknesses and two SAMs with rather diverse chemical properties, using the benchmark organic semiconductor dinaphtho[2,3-b:2',3'-f]thieno[3,2-b]thiophene. Unlike several previous studies, we have found that the dependence of the threshold voltage on the gate-dielectric capacitance is completely different for the two SAMs. In transistors with an alkyl SAM, the threshold voltage does not depend on the gate-dielectric capacitance and is determined mainly by the dipolar character of the SAM, whereas in transistors with a fluoroalkyl SAM the threshold voltages exhibit a linear dependence on the inverse of the gate-dielectric capacitance. Kelvin probe force microscopy measurements indicate this behavior is attributed to an electronic coupling between the fluoroalkyl SAM and the organic semiconductor.
Roujol, Sebastien; Basha, Tamer A; Tan, Alex; Khanna, Varun; Chan, Raymond H; Moghari, Mehdi H; Rayatzadeh, Hussein; Shaw, Jaime L; Josephson, Mark E; Nezafat, Reza
2013-05-01
Electroanatomical voltage mapping (EAVM) is commonly performed prior to catheter ablation of scar-related ventricular tachycardia (VT) to locate the arrhythmic substrate and to guide the ablation procedure. EAVM is used to locate the position of the ablation catheter and to provide a 3-D reconstruction of left-ventricular anatomy and scar. However, EAVM measurements only represent the endocardial scar with no transmural or epicardial information. Furthermore, EAVM is a time-consuming procedure, with a high operator dependence and has low sampling density, i.e., spatial resolution. Late gadolinium enhancement (LGE) magnetic resonance imaging (MRI) allows noninvasive assessment of scar morphology that can depict 3-D scar architecture. Despite the potential use of LGE as a roadmap for VT ablation for identification of arrhythmogenic substrate, its utility has been very limited. To allow for identification of VT substrate, a correlation is needed between the substrates identified by EAVM as the gold standard and LGE-MRI scar characteristics. To do so, a system must be developed to fuse the datasets from these modalities. In this study, a registration pipeline for the fusion of LGE-MRI and EAVM data is presented. A novel surface registration algorithm is proposed, integrating the matching of global scar areas as an additional constraint in the registration process. A preparatory landmark registration is initially performed to expedite the convergence of the algorithm. Numerical simulations were performed to evaluate the accuracy of the registration in the presence of errors in identifying landmarks in EAVM or LGE-MRI datasets as well as additional errors due to respiratory or cardiac motion. Subsequently, the accuracy of the proposed fusion system was evaluated in a cohort of ten patients undergoing VT ablation where both EAVM and LGE-MRI data were available. Compared to landmark registration and surface registration, the presented method achieved significant improvement in registration error. The proposed data fusion system allows the fusion of EAVM and LGE-MRI data in VT ablation with registration errors less than 3.5 mm.
Oxygen consumption and heart rate responses to isolated ballet exercise sets.
Rodrigues-Krause, Josianne; Dos Santos Cunha, Giovani; Alberton, Cristine Lima; Follmer, Bruno; Krause, Mauricio; Reischak-Oliveira, Alvaro
2014-01-01
Ballet stage performances are associated with higher cardiorespiratory demand than rehearsals and classes. Hence, new interest is emerging to create periodized training that enhances dancers' fitness while minimizing delayed exercise-induced fatigue and possible injuries. Finding out in what zones of intensity dancers work during different ballet movements may support the use of supplemental training adjusted to the needs of the individual dancer. Therefore, the main purpose of this study was to describe dancers' oxygen consumption (VO2) and heart rate (HR) responses during the performance of nine isolated ballet exercise sets, as correlated with their first and second ventilatory thresholds (VT1 and VT2). Twelve female ballet dancers volunteered for the study. Their maximum oxygen consumption (VO2max), VT1, and VT2 were determined by use of an incremental treadmill test. Nine sets of ballet movements were assessed: pliés, tendus, jetés, rond de jambes, fondus, grand adage (adage), grand battements, temps levés, and sautés. The sets were randomly executed and separated by 5 minute rest periods. ANOVA for repeated measurements followed by the Bonferroni Post-hoc test were applied (p < 0.05). VO2 responses were as follows: pliés (17.6 ± 1.6 ml·kg(-1)·min(-1)); tendus and adage were not significantly greater than VT1; rond de jambes (21.8 ± 3.1 ml·kg(-1) ·min(-1)); fondus and jetés were higher than VT1 and the previous exercises; grand battements (25.8 ± 2.9 ml·kg(-1)·min(-1)) was greater than all the other exercises and VT1; and VT2 was significantly higher than all ballet sets. This stratification followed closely, but not exactly, the variation in HR. For example, rond de jambes (156.8 ± 19 b·min(-1)) did not show any significant difference from all the other ballet sets, nor VT1 or VT2. It is concluded that the workloads of isolated ballet sets, based on VO2 responses, vary between low and moderate aerobic intensity in relation to dancers' VT1 and VT2. However, ballet set workloads may be higher when based on HR responses, due to the intermittent and isometric components of dance.
NASA Astrophysics Data System (ADS)
Shin, Hee-Sun; Lee, Won-Kyu; Park, Sang-Guen; Kuk, Seung-Hee; Han, Min-Koo
2009-03-01
A new hydrogenated amorphous silicon (a-Si:H) thin film transistor (TFT) pixel circuit for active-matrix organic light emission diodes (AM-OLEDs), which significantly compensates the OLED current degradation by memorizing the threshold voltage of driving TFT and suppresses the threshold voltage shift of a-Si:H TFTs by negative bias annealing, is proposed and fabricated. During the first half of each frame, the driving TFT of the proposed pixel circuit supplies current to the OLED, which is determined by modified data voltage in the compensation scheme. The proposed pixel circuit was able to compensate the threshold voltage shift of the driving TFT as well as the OLED. During the remaining half of each frame, the proposed pixel circuit induces the recovery of the threshold voltage degradation of a-Si:H TFTs owing to the negative bias annealing. The experimental results show that the proposed pixel circuit was able to successfully compensate for the OLED current degradation and suppress the threshold voltage degradation of the driving TFT.
Influence of Training Load and Altitude on HRV Fatigue Patterns in Elite Nordic Skiers.
Schmitt, Laurent; Regnard, Jacques; Coulmy, Nicolas; Millet, Gregoire P
2018-06-14
We aimed to analyse the relationship between training load/intensity and different heart rate variability (HRV) fatigue patterns in 57 elite Nordic-skiers. 1063 HRV tests were performed during 5 years. R-R intervals were recorded in resting supine (SU) and standing (ST) positions. Heart rate, low (LF), high (HF) frequency powers of HRV were determined. Training volume, training load (TL, a.u.) according to ventilatory threshold 1 (VT1) and VT2 were measured in zones I≤VT1; VT1
Tempest, Gavin D; Parfitt, Gaynor
2017-07-01
The interplay between the prefrontal cortex and amygdala is proposed to explain the regulation of affective responses (pleasure/displeasure) during exercise as outlined in the dual-mode model. However, due to methodological limitations the dual-mode model has not been fully tested. In this study, prefrontal oxygenation (using near-infrared spectroscopy) and amygdala activity (reflected by eyeblink amplitude using acoustic startle methodology) were recorded during exercise standardized to metabolic processes: 80% of ventilatory threshold (below VT), at the VT, and at the respiratory compensation point (RCP). Self-reported tolerance of the intensity of exercise was assessed prior to, and affective responses recorded during exercise. The results revealed that, as the intensity of exercise became more challenging (from below VT to RCP), prefrontal oxygenation was larger and eyeblink amplitude and affective responses were reduced. Below VT and at VT, larger prefrontal oxygenation was associated with larger eyeblink amplitude. At the RCP, prefrontal oxygenation was greater in the left than right hemisphere, and eyeblink amplitude explained significant variance in affective responses (with prefrontal oxygenation) and self-reported tolerance. These findings highlight the role of the prefrontal cortex and potentially the amygdala in the regulation of affective (particularly negative) responses during exercise at physiologically challenging intensities (above VT). In addition, a psychophysiological basis of self-reported tolerance is indicated. This study provides some support of the dual-mode model and insight into the neural basis of affective responses during exercise. © 2017 Society for Psychophysiological Research.
High voltage threshold for stable operation in a dc electron gun
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamamoto, Masahiro, E-mail: masahiro@post.kek.jp; Nishimori, Nobuyuki, E-mail: n-nishim@tagen.tohoku.ac.jp
We report clear observation of a high voltage (HV) threshold for stable operation in a dc electron gun. The HV hold-off time without any discharge is longer than many hours for operation below the threshold, while it is roughly 10 min above the threshold. The HV threshold corresponds to the minimum voltage where discharge ceases. The threshold increases with the number of discharges during HV conditioning of the gun. Above the threshold, the amount of gas desorption per discharge increases linearly with the voltage difference from the threshold. The present experimental observations can be explained by an avalanche discharge modelmore » based on the interplay between electron stimulated desorption (ESD) from the anode surface and subsequent secondary electron emission from the cathode by the impact of ionic components of the ESD molecules or atoms.« less
Optimal programming management of ventricular tachycardia storm in ICD patients
Qian, Zhiyong; Guo, Jianghong; Zhang, Zhiyong; Wang, Yao; Hou, Xiaofeng; Zou, Jiangang
2015-01-01
Abstract Ventricular tachycardia storm (VTS) is defined as a life-threatening syndrome of three or more separate episodes of ventricular tachycardia (VT) leading to implantable cardioverter defibrillator (ICD) therapy within 24 hours. Patients with VTS have poor outcomes and require immediate medical attention. ICD shocks have been shown to be associated with increased mortality in several studies. Optimal programming in minimization of ICD shocks may decrease mortality. Large controlled trials showed that long detection time and high heart rate detection threshold reduced ICD shock burden without an increase in syncope or death. As a fundamental therapy of ICD, antitachycardia pacing (ATP) can terminate most slow VT with a low risk of acceleration. For fast VT, burst pacing is more effective and less likely to result in acceleration than ramp pacing. One algorithm of optimal programming management during a VTS is presented in the review. PMID:25745473
Tempest, Gavin; Parfitt, Gaynor
2013-10-01
Imagery, as a cognitive strategy, can improve affective responses during moderate-intensity exercise. The effects of imagery at higher intensities of exercise have not been examined. Further, the effect of imagery use and activity in the frontal cortex during exercise is unknown. Using a crossover design (imagery and control), activity of the frontal cortex (reflected by changes in cerebral hemodynamics using near-infrared spectroscopy) and affective responses were measured during exercise at intensities 5% above the ventilatory threshold (VT) and the respiratory compensation point (RCP). Results indicated that imagery use influenced activity of the frontal cortex and was associated with a more positive affective response at intensities above VT, but not RCP to exhaustion (p < .05). These findings provide direct neurophysiological evidence of imagery use and activity in the frontal cortex during exercise at intensities above VT that positively impact affective responses.
[Effect of training intensity on the fat oxidation rate].
Ulloa, David; Feriche, Belén; Barboza, Paola; Padial, Paulino
2014-01-01
Physical exercise is a key modulator of the maximum fat oxidation rate (MFO). However, the metabolic transition zones in the MFO-exercise relationship are not generally considered for training prescription. Objective. To examine the effects of training in different metabolic transition zones on the kinetics of MFO and its localization (Fatmax) in young physically active men. 97 men were divided into 4 similar sized groups, 3 experimental groups and a control group (CG). Subjects in each experimental group undertook an 8-week running program. Training was continuous at the intensity of the aerobic threshold or VT1 (CCVT1); or performed as intervals at the intensity of the anaerobic threshold or VT2 (ITVT2); or at maximum aerobic power VO2max (ITVO2max). Before and after the training intervention, expired gases were monitored in each subject to determine VO2max, VT1, VT2, MFO (by indirect calorimetry) and Fatmax. In response to training, experimental groups showed an increase in MFO (from 16,49 to 18,51%; p<0,01) and a mean reduction in Fatmax of 60,72±10,52 to 52,35±7,61 %VO2max (p<0,01). No changes of interest were observed in the control subjects. Intergroup comparisons revealed no differences in MFO and Fatmax among the experimental groups, though compared to the CG, a greater reduction in Fatmax was observed in CCVT1 (p<0,05). No changes were detected in performance except a drop in VO2max in the GC (p<0,05). 8 weeks of training led to an increase in MFO and reduction in Fatmax irrespective of training intensity. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Boyne, Pierce; Buhr, Sarah; Rockwell, Bradley; Khoury, Jane; Carl, Daniel; Gerson, Myron; Kissela, Brett; Dunning, Kari
2015-10-01
Treadmill aerobic exercise improves gait, aerobic capacity, and cardiovascular health after stroke, but a lack of specificity in current guidelines could lead to underdosing or overdosing of aerobic intensity. The ventilatory threshold (VT) has been recommended as an optimal, specific starting point for continuous aerobic exercise. However, VT measurement is not available in clinical stroke settings. Therefore, the purpose of this study was to identify an accurate method to predict heart rate at the VT (HRVT) for use as a surrogate for VT. A cross-sectional design was employed. Using symptom-limited graded exercise test (GXT) data from 17 subjects more than 6 months poststroke, prediction methods for HRVT were derived by traditional target HR calculations (percentage of HRpeak achieved during GXT, percentage of peak HR reserve [HRRpeak], percentage of age-predicted maximal HR, and percentage of age-predicted maximal HR reserve) and by regression analysis. The validity of the prediction methods was then tested among 8 additional subjects. All prediction methods were validated by the second sample, so data were pooled to calculate refined prediction equations. HRVT was accurately predicted by 80% HRpeak (R, 0.62; standard deviation of error [SDerror], 7 bpm), 62% HRRpeak (R, 0.66; SDerror, 7 bpm), and regression models that included HRpeak (R, 0.62-0.75; SDerror, 5-6 bpm). Derived regression equations, 80% HRpeak and 62% HRRpeak, provide a specific target intensity for initial aerobic exercise prescription that should minimize underdosing and overdosing for persons with chronic stroke. The specificity of these methods may lead to more efficient and effective treatment for poststroke deconditioning.Video Abstract available for more insights from the authors (see Supplemental Digital Content 1, http://links.lww.com/JNPT/A114).
Intensity related changes of running economy in recreational level distance runners.
Engeroff, Tobias; Bernardi, Andreas; Niederer, Daniel; Wilke, Jan; Vogt, Lutz; Banzer, Winfried
2017-09-01
Running economy (RE) is often described as a key demand of running performance. The variety of currently used assessment methods with different running intensities and outcomes restricts interindividual comparability of RE in recreational level runners. The purpose of this study was to compare the influence of RE, assessed as oxygen cost (OC) and caloric unit cost (CUC), on running speed at individual physiological thresholds. Eighteen recreational runners performed: 1) a graded exercise test to estimate first ventilatory threshold (VT1), respiratory compensation point (RCP) and maximal oxygen uptake (VO2max); 2) discontinuous RE assessment to determine relative OC in milliliters per kilogram per kilometer (mL/kg/km) and CUC in kilocalories per kilogram per kilometer (kcal/kg/km) at three different running intensities: VT1, RCP and at a third standardized reference point (TP) in between. OC (mL/kg/km; at VT1: 235.4±26.2; at TP: 227.8±23.4; at RCP: 224.9±21.9) and CUC (kcal/kg/km at VT1: 1.18±0.13; at TP: 1.14±0.12; at RCP: 1.13±0.11) decreased with increasing intensities (P≤0.01). Controlling for the influence of sex OC and CUC linearly correlated with running speed at RCP and VO2max (P≤0.01). RE, even assessed at low intensity, is strongly related to running performance in recreational athletes. Both calculation methods used (OC and CUC) are sensitive for monitoring intensity related changes of substrate utilization. RE values decreased with higher running intensity indicating an increase of anaerobic and subsequent decrease of aerobic substrate utilization.
Noninvasive method to estimate anaerobic threshold in individuals with type 2 diabetes.
Sales, Marcelo M; Campbell, Carmen Sílvia G; Morais, Pâmella K; Ernesto, Carlos; Soares-Caldeira, Lúcio F; Russo, Paulo; Motta, Daisy F; Moreira, Sérgio R; Nakamura, Fábio Y; Simões, Herbert G
2011-01-12
While several studies have identified the anaerobic threshold (AT) through the responses of blood lactate, ventilation and blood glucose others have suggested the response of the heart rate variability (HRV) as a method to identify the AT in young healthy individuals. However, the validity of HRV in estimating the lactate threshold (LT) and ventilatory threshold (VT) for individuals with type 2 diabetes (T2D) has not been investigated yet. To analyze the possibility of identifying the heart rate variability threshold (HRVT) by considering the responses of parasympathetic indicators during incremental exercise test in type 2 diabetics subjects (T2D) and non diabetics individuals (ND). Nine T2D (55.6 ± 5.7 years, 83.4 ± 26.6 kg, 30.9 ± 5.2 kg.m2(-1)) and ten ND (50.8 ± 5.1 years, 76.2 ± 14.3 kg, 26.5 ± 3.8 kg.m2(-1)) underwent to an incremental exercise test (IT) on a cycle ergometer. Heart rate (HR), rate of perceived exertion (RPE), blood lactate and expired gas concentrations were measured at the end of each stage. HRVT was identified through the responses of root mean square successive difference between adjacent R-R intervals (RMSSD) and standard deviation of instantaneous beat-to-beat R-R interval variability (SD1) by considering the last 60 s of each incremental stage, and were known as HRVT by RMSSD and SD1 (HRVT-RMSSD and HRVT-SD1), respectively. No differences were observed within groups for the exercise intensities corresponding to LT, VT, HRVT-RMSSD and HHVT-SD1. Furthermore, a strong relationship were verified among the studied parameters both for T2D (r = 0.68 to 0.87) and ND (r = 0.91 to 0.98) and the Bland & Altman technique confirmed the agreement among them. The HRVT identification by the proposed autonomic indicators (SD1 and RMSSD) were demonstrated to be valid to estimate the LT and VT for both T2D and ND.
Device for monitoring cell voltage
Doepke, Matthias [Garbsen, DE; Eisermann, Henning [Edermissen, DE
2012-08-21
A device for monitoring a rechargeable battery having a number of electrically connected cells includes at least one current interruption switch for interrupting current flowing through at least one associated cell and a plurality of monitoring units for detecting cell voltage. Each monitoring unit is associated with a single cell and includes a reference voltage unit for producing a defined reference threshold voltage and a voltage comparison unit for comparing the reference threshold voltage with a partial cell voltage of the associated cell. The reference voltage unit is electrically supplied from the cell voltage of the associated cell. The voltage comparison unit is coupled to the at least one current interruption switch for interrupting the current of at least the current flowing through the associated cell, with a defined minimum difference between the reference threshold voltage and the partial cell voltage.
Janardhan, Ajit H.; Li, Wenwen; Fedorov, Vadim V.; Yeung, Michael; Wallendorf, Michael J.; Schuessler, Richard B.; Efimov, Igor R.
2015-01-01
Objectives To develop a low-energy electrotherapy that terminates ventricular tachycardia (VT) when anti-tachycardia pacing (ATP) fails. Background High-energy ICD shocks are associated with device failure, significant morbidity and increased mortality. A low-energy alternative to ICD shocks is desirable. Methods Myocardial infarction (MI) was created in 25 dogs. Sustained, monomorphic VT was induced by programmed stimulation. Defibrillation electrodes were placed in the RV apex, and coronary sinus (CS) and LV epicardium (LVP). If ATP failed to terminate sustained VT, the defibrillation thresholds (DFTs) of standard versus experimental electrotherapies were measured. Results Sustained VT ranged from 276–438 bpm (mean 339 bpm). The RV-CS shock vector had lower impedance than RV-LVP (54.4±18.1 Ω versus 109.8±16.9, Ω p<0.001). A single shock required between 0.3±0.2 J to 5.9±2.5 J (mean 2.64±3.22 J; p=0.008) to terminate VT, and varied depending upon the phase of the VT cycle at which it was delivered. In contrast, multiple shocks delivered within 1 VT cycle length were not phase-dependent and achieved lower DFT compared to a single shock (0.13±0.09 J for 3 shocks, 0.08±0.04 J for 5 shocks, 0.09±0.07 J for 7 shocks; p<0.001). Finally, a multi-stage electrotherapy (MSE) achieved significantly lower DFT compared to a single biphasic shock (0.03±0.05 J versus 2.37±1.20 J, respectively, p<0.001). At a peak shock amplitude of 20 V, MSE achieved 91.3% of terminations versus 10.5% for a biphasic shock (p<0.001). Conclusions MSE achieved a major reduction in DFT compared to a single biphasic shock for ATP-refractory monomorphic VT, and represents a novel electrotherapy to reduce high-energy ICD shocks. PMID:23141483
Spike-Threshold Variability Originated from Separatrix-Crossing in Neuronal Dynamics
Wang, Longfei; Wang, Hengtong; Yu, Lianchun; Chen, Yong
2016-01-01
The threshold voltage for action potential generation is a key regulator of neuronal signal processing, yet the mechanism of its dynamic variation is still not well described. In this paper, we propose that threshold phenomena can be classified as parameter thresholds and state thresholds. Voltage thresholds which belong to the state threshold are determined by the ‘general separatrix’ in state space. We demonstrate that the separatrix generally exists in the state space of neuron models. The general form of separatrix was assumed as the function of both states and stimuli and the previously assumed threshold evolving equation versus time is naturally deduced from the separatrix. In terms of neuronal dynamics, the threshold voltage variation, which is affected by different stimuli, is determined by crossing the separatrix at different points in state space. We suggest that the separatrix-crossing mechanism in state space is the intrinsic dynamic mechanism for threshold voltages and post-stimulus threshold phenomena. These proposals are also systematically verified in example models, three of which have analytic separatrices and one is the classic Hodgkin-Huxley model. The separatrix-crossing framework provides an overview of the neuronal threshold and will facilitate understanding of the nature of threshold variability. PMID:27546614
Spike-Threshold Variability Originated from Separatrix-Crossing in Neuronal Dynamics.
Wang, Longfei; Wang, Hengtong; Yu, Lianchun; Chen, Yong
2016-08-22
The threshold voltage for action potential generation is a key regulator of neuronal signal processing, yet the mechanism of its dynamic variation is still not well described. In this paper, we propose that threshold phenomena can be classified as parameter thresholds and state thresholds. Voltage thresholds which belong to the state threshold are determined by the 'general separatrix' in state space. We demonstrate that the separatrix generally exists in the state space of neuron models. The general form of separatrix was assumed as the function of both states and stimuli and the previously assumed threshold evolving equation versus time is naturally deduced from the separatrix. In terms of neuronal dynamics, the threshold voltage variation, which is affected by different stimuli, is determined by crossing the separatrix at different points in state space. We suggest that the separatrix-crossing mechanism in state space is the intrinsic dynamic mechanism for threshold voltages and post-stimulus threshold phenomena. These proposals are also systematically verified in example models, three of which have analytic separatrices and one is the classic Hodgkin-Huxley model. The separatrix-crossing framework provides an overview of the neuronal threshold and will facilitate understanding of the nature of threshold variability.
NASA Technical Reports Server (NTRS)
Asenov, Asen
1998-01-01
A three-dimensional (3-D) "atomistic" simulation study of random dopant induced threshold voltage lowering and fluctuations in sub-0.1 microns MOSFET's is presented. For the first time a systematic analysis of random dopant effects down to an individual dopant level was carried out in 3-D on a scale sufficient to provide quantitative statistical predictions. Efficient algorithms based on a single multigrid solution of the Poisson equation followed by the solution of a simplified current continuity equation are used in the simulations. The effects of various MOSFET design parameters, including the channel length and width, oxide thickness and channel doping, on the threshold voltage lowering and fluctuations are studied using typical samples of 200 atomistically different MOSFET's. The atomistic results for the threshold voltage fluctuations were compared with two analytical models based on dopant number fluctuations. Although the analytical models predict the general trends in the threshold voltage fluctuations, they fail to describe quantitatively the magnitude of the fluctuations. The distribution of the atomistically calculated threshold voltage and its correlation with the number of dopants in the channel of the MOSFET's was analyzed based on a sample of 2500 microscopically different devices. The detailed analysis shows that the threshold voltage fluctuations are determined not only by the fluctuation in the dopant number, but also in the dopant position.
NASA Astrophysics Data System (ADS)
Takahashi, Hajime; Hanafusa, Yuki; Kimura, Yoshinari; Kitamura, Masatoshi
2018-03-01
Oxygen plasma treatment has been carried out to control the threshold voltage in organic thin-film transistors (TFTs) having a SiO2 gate dielectric prepared by rf sputtering. The threshold voltage linearly changed in the range of -3.7 to 3.1 V with the increase in plasma treatment time. Although the amount of change is smaller than that for organic TFTs having thermally grown SiO2, the tendency of the change was similar to that for thermally grown SiO2. To realize different plasma treatment times on the same substrate, a certain region on the SiO2 surface was selected using a shadow mask, and was treated with oxygen plasma. Using the process, organic TFTs with negative threshold voltages and those with positive threshold voltages were fabricated on the same substrate. As a result, enhancement/depletion inverters consisting of the organic TFTs operated at supply voltages of 5 to 15 V.
Sunderland, Kyle L; Greer, Felicia; Morales, Jacobo
2011-03-01
The ergogenic effect of L-arginine on an endurance-trained population is not well studied. The few studies that have investigated L-arginine on this population have not been conducted in a laboratory setting or measured aerobic variables. The purpose of the current study is to determine if 28 days of L-arginine supplementation in trained male cyclists affects VO2max and ventilatory threshold (VT). Eighteen (18) endurance-trained male cyclists (mean ± SD, age: 36.3 ± 7.9 years; height: 182.4 ± 4.6 cm; and body mass: 79.5 ± 4.7 kg) performed a graded exercise test (GXT; 50 W + 25 W·min) before and after 28 days of supplementation with L-arginine (ARG; 2 × 6 g·d) or placebo (PLA; cornstarch). The GXT was conducted on the subject's own bicycle using the RacerMate CompuTrainer (Seattle, WA, USA). VO2 was continuously recorded using the ParvoMedics TrueOne 2400 metabolic cart (Salt Lake City, UT, USA) and VT was established by plotting the ventilatory equivalent for O2 (VE/VO2) and the ventilatory equivalent for CO2 (VE/VCO2) and identifying the point at which VE/VO2 increases with no substantial changes in VE/VCO2. L-arginine supplementation had no effect from initial VO2max (PL, 58.7 ± 7.1 ml·kg·min; ARG, 63.5 ± 7.3 ml·kg·min) to postsupplement VO2max (PL, 58.9 ± 6.0 ml·kg·min; ARG, 63.2 ± 7.2 ml·kg·min). Also, no effect was seen from initial VT (PL, 75.7 ± 4.6% VO2max; ARG, 76.0 ± 5.3% VO2max) to postsupplement VT (PL, 74.3 ± 8.1% VO2max; ARG, 74.2 ± 6.4% VO2max). These results indicate that L-arginine does not impact VO2max or VT in trained male cyclists.
NASA Astrophysics Data System (ADS)
Rettmann, M. E.; Suzuki, A.; Wang, S.; Pottinger, N.; Arter, J.; Netzer, A.; Parker, K.; Viker, K.; Packer, D. L.
2017-03-01
Myocardial scarring creates a substrate for reentrant circuits which can lead to ventricular tachycardia. In ventricular catheter ablation therapy, regions of myocardial scarring are targeted to interrupt arrhythmic electrical pathways. Low voltage regions are a surrogate for myocardial scar and are identified by generating an electro anatomic map at the start of the procedure. Recent efforts have focussed on integration of preoperative scar information generated from delayed contrast-enhanced MR imaging to augment intraprocedural information. In this work, we describe an initial feasibility study of integration of a preoperative MRI derived scar maps into a high-resolution mapping system to improve planning and guidance of VT ablation procedures.
Hafnium transistor process design for neural interfacing.
Parent, David W; Basham, Eric J
2009-01-01
A design methodology is presented that uses 1-D process simulations of Metal Insulator Semiconductor (MIS) structures to design the threshold voltage of hafnium oxide based transistors used for neural recording. The methodology is comprised of 1-D analytical equations for threshold voltage specification, and doping profiles, and 1-D MIS Technical Computer Aided Design (TCAD) to design a process to implement a specific threshold voltage, which minimized simulation time. The process was then verified with a 2-D process/electrical TCAD simulation. Hafnium oxide films (HfO) were grown and characterized for dielectric constant and fixed oxide charge for various annealing temperatures, two important design variables in threshold voltage design.
Constant-current regulator improves tunnel diode threshold-detector performance
NASA Technical Reports Server (NTRS)
Cancro, C. A.
1965-01-01
Grounded-base transistor is placed in a tunnel diode threshold detector circuit, and a bias voltage is applied to the tunnel diode. This provides the threshold detector with maximum voltage output and overload protection.
NASA Astrophysics Data System (ADS)
Fan, Ching-Lin; Lin, Yu-Sheng; Liu, Yan-Wei
A new pixel design and driving method for active matrix organic light emitting diode (AMOLED) displays that use low-temperature polycrystalline silicon thin-film transistors (LTPS-TFTs) with a voltage programming method are proposed and verified using the SPICE simulator. We had employed an appropriate TFT model in SPICE simulation to demonstrate the performance of the pixel circuit. The OLED anode voltage variation error rates are below 0.35% under driving TFT threshold voltage deviation (Δ Vth =± 0.33V). The OLED current non-uniformity caused by the OLED threshold voltage degradation (Δ VTO =+0.33V) is significantly reduced (below 6%). The simulation results show that the pixel design can improve the display image non-uniformity by compensating for the threshold voltage deviation in the driving TFT and the OLED threshold voltage degradation at the same time.
See hear: psychological effects of music and music-video during treadmill running.
Hutchinson, Jasmin C; Karageorghis, Costas I; Jones, Leighton
2015-04-01
There is a paucity of work addressing the distractive, affect-enhancing, and motivational influences of music and video in combination during exercise. We examined the effects of music and music-and-video on a range of psychological and psychophysical variables during treadmill running at intensities above and below ventilatory threshold (VT). Participants (N = 24) exercised at 10 % of maximal capacity below VT and 10 % above under music-only, music-and-video, and control conditions. There was a condition × intensity × time interaction for perceived activation and state motivation, and an intensity × time interaction for state attention, perceived exertion (RPE), and affective valence. The music-and-video condition elicited the highest levels of dissociation, lowest RPE, and most positive affective responses regardless of exercise intensity. Attentional manipulations influence psychological and psychophysical variables at exercise intensities above and below VT, and this effect is enhanced by the combined presentation of auditory and visual stimuli.
NASA Astrophysics Data System (ADS)
Shukla, Krishna Dayal; Saxena, Nishant; Durai, Suresh; Manivannan, Anbarasu
2016-11-01
Although phase-change memory (PCM) offers promising features for a ‘universal memory’ owing to high-speed and non-volatility, achieving fast electrical switching remains a key challenge. In this work, a correlation between the rate of applied voltage and the dynamics of threshold-switching is investigated at picosecond-timescale. A distinct characteristic feature of enabling a rapid threshold-switching at a critical voltage known as the threshold voltage as validated by an instantaneous response of steep current rise from an amorphous off to on state is achieved within 250 picoseconds and this is followed by a slower current rise leading to crystallization. Also, we demonstrate that the extraordinary nature of threshold-switching dynamics in AgInSbTe cells is independent to the rate of applied voltage unlike other chalcogenide-based phase change materials exhibiting the voltage dependent transient switching characteristics. Furthermore, numerical solutions of time-dependent conduction process validate the experimental results, which reveal the electronic nature of threshold-switching. These findings of steep threshold-switching of ‘sub-50 ps delay time’, opens up a new way for achieving high-speed non-volatile memory for mainstream computing.
Reconfigurable ultra-thin film GDNMOS device for ESD protection in 28 nm FD-SOI technology
NASA Astrophysics Data System (ADS)
Athanasiou, Sotirios; Legrand, Charles-Alexandre; Cristoloveanu, Sorin; Galy, Philippe
2017-02-01
We propose a novel ESD protection device (GDNMOS: Gated Diode merged NMOS) fabricated with 28 nm UTBB FD-SOI high-k metal gate technology. By modifying the combination of the diode and transistor gate stacks, the robustness of the device is optimized, achieving a maximum breakdown voltage (VBR) of 4.9 V. In addition, modifications of the gate length modulate the trigger voltage (Vt1) with a minimum value of 3.5 V. Variable electrostatic doping (gate-induced) in diode and transistor body enables reconfigurable operation. A lower doping of the base enhances the bipolar gain, leading to thyristor behavior. This innovative architecture demonstrates excellent capability for high-voltage protection while maintaining a latch-up free behavior.
Cardiorespiratory responses of a dance session designed for older women: A cross sectional study.
Rodrigues-Krause, Josianne; Farinha, Juliano Boufleur; Ramis, Thiago Rozales; Boeno, Francesco Pinto; Dos Santos, Gabriela Cristina; Krause, Mauricio; Reischak-Oliveira, Alvaro
2018-06-04
Dancing has been increasingly used as a type of exercise intervention to improve cardiovascular fitness of older people. However, it is unclear which may be the exercise intensity of the dance sessions. To describe cardiorespiratory responses of a dance session for older women, and to identify intensity zones in relation to peak oxygen consumption (VO 2 peak), first and second ventilatory thresholds (VT1 and VT2). Ten women (66 ± 5 yrs., BMI 27 ± 4) were examined on three occasions: Familiarization, maximum effort and dance sessions. Incremental treadmill test: 5 km/h, 2% slope each min, until maximum effort. Dance class (60 min): warm-up (20 min), across-the-floor (10 min), choreography (15 min), show (10 min) and cool-down (5 min). Ventilatory parameters were measured continuously (breath-by-breath). VO 2 (mL·kg -1 ·min -1 ): Maximum effort: VO 2 peak (23.3 ± 4.3), VT1 (17.2 ± 3.5) and VT2 (20.9 ± 3.4). Dancing: warm-up (12.8 ± 2.4, ~55%VO 2 peak), across-the-floor (14.2 ± 2.4 ~62%VO 2 peak), choreography (14.6 ± 3.2 ~63%VO 2 peak) and show (16.1 ± 3.3, ~69% VO 2 peak). Show was similar to VT1. Cardiorespiratory demands of a dance class for older women are at low aerobic intensity. Show was similar to VT1, indicating that a dance class may be modulated to improve aerobic fitness, at least at initial stages of training. Copyright © 2018 Elsevier Inc. All rights reserved.
Maximal lactate steady state determination with a single incremental test exercise.
Laplaud, David; Guinot, Michel; Favre-Juvin, Anne; Flore, Patrice
2006-03-01
The aim of this study was to determine whether the power output associated with a maximal lactate steady state (MLSS) (.W(MLSS)) can be assessed using a single incremental cycling test. Eleven recreational sportsmen (age: 22+/-1 years, height: 175+/-6 cm, weight: 71+/-5 kg) volunteered to participate in the study. For each subject the first and second ventilatory thresholds (VT(1) and VT(2), respectively) and the power output corresponding to (respiratory exchange ratio) RER=1.00 were determined during an incremental test to exhaustion. Thereafter, each subject performed several 30-min constant load tests to determine MLSS. The workload used in the first constant test was set to the .W(RER=1.00) determined during the incremental test. .W(VT1) (175+/-24 W) and .W(VT2) (265+/-31 W) were significantly different from .W(MLSS )(220+/-36 W). Whereas, .W(RER=1.00) (224+/-33 W) was similar to .W(MLSS). HR, RER and .VE were significantly different between the 10th and the 30th minutes when exercising at .W(RER=1.00) and at .W(MLSS). In contrast, .VO(2) and .VCO(2) were stable over those 30-min constant tests. Power output at VT(1), RER=1.00 and VT(2) were all correlated to .W(MLSS) but the relationship was stronger between RER=1.00 and MLSS (R (2)=0.95). The present study shows that the power output associated with a RER value equal to 1.00 during an incremental test does not differ from that determined for MLSS. Hence, the MLSS can be estimated with a single exercise test.
Multibias and thermal behavior of microwave GaN and GaAs based HEMTs
NASA Astrophysics Data System (ADS)
Alim, Mohammad A.; Rezazadeh, Ali A.; Gaquiere, Christophe
2016-12-01
Multibias and thermal characterizations on 0.25 μm × (2 × 100) μm AlGaN/GaN/SiC HEMT and 0.5 μm × (2 × 100) μm AlGaAs/InGaAs pseudomorphic HEMT have carried out for the first time. Two competitive device technologies are investigated with the variations of bias and temperature in order to afford a detailed realization of their potentialities. The main finding includes the self heating effect in the GaN device, zero temperature coefficient points at the drain current and transconductance in the GaAs device. The thermal resistance RTH of 7.1, 8.2 and 9.4 °C mm/W for the GaN device was estimated at 25, 75 and 150 °C respectively which are consistent with those found in the open literature. The temperature trend of the threshold voltage VT, Schottky barrier height ϕb, sheet charge densities of two dimensional electron gas ns, and capacitance under the gate Cg are exactly opposite in the two devices; whereas the knee voltage Vk, on resistance Ron, and series resistance Rseries are shows similar trend. The multi-bias and thermal behavior of the output current Ids, output conductance gds, transconductance gm, cut-off frequency ft, maximum frequency fmax, effective velocity of electron, veff and field dependent mobility, μ demonstrates a great potential of GaN device. These results provide some valuable insights for technology of preference for future and current applications.
Method and system for controlling a rotational speed of a rotor of a turbogenerator
Stahlhut, Ronnie Dean; Vuk, Carl Thomas
2008-12-30
A system and method controls a rotational speed of a rotor or shaft of a turbogenerator in accordance with a present voltage level on a direct current bus. A lower threshold and a higher threshold are established for a speed of a rotor or shaft of a turbogenerator. A speed sensor determines speed data or a speed signal for the rotor or shaft associated with a turbogenerator. A voltage regulator adjusts a voltage level associated with a direct current bus within a target voltage range if the speed data or speed signal indicates that the speed is above the higher threshold or below the lower threshold.
Dynamic and Tunable Threshold Voltage in Organic Electrochemical Transistors.
Doris, Sean E; Pierre, Adrien; Street, Robert A
2018-04-01
In recent years, organic electrochemical transistors (OECTs) have found applications in chemical and biological sensing and interfacing, neuromorphic computing, digital logic, and printed electronics. However, the incorporation of OECTs in practical electronic circuits is limited by the relative lack of control over their threshold voltage, which is important for controlling the power consumption and noise margin in complementary and unipolar circuits. Here, the threshold voltage of OECTs is precisely tuned over a range of more than 1 V by chemically controlling the electrochemical potential at the gate electrode. This threshold voltage tunability is exploited to prepare inverters and amplifiers with improved noise margin and gain, respectively. By coupling the gate electrode with an electrochemical oscillator, single-transistor oscillators based on OECTs with dynamic time-varying threshold voltages are prepared. This work highlights the importance of electrochemistry at the gate electrode in determining the electrical properties of OECTs, and opens a path toward the system-level design of low-power OECT-based electronics. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lower-Order Compensation Chain Threshold-Reduction Technique for Multi-Stage Voltage Multipliers.
Dell' Anna, Francesco; Dong, Tao; Li, Ping; Wen, Yumei; Azadmehr, Mehdi; Casu, Mario; Berg, Yngvar
2018-04-17
This paper presents a novel threshold-compensation technique for multi-stage voltage multipliers employed in low power applications such as passive and autonomous wireless sensing nodes (WSNs) powered by energy harvesters. The proposed threshold-reduction technique enables a topological design methodology which, through an optimum control of the trade-off among transistor conductivity and leakage losses, is aimed at maximizing the voltage conversion efficiency (VCE) for a given ac input signal and physical chip area occupation. The conducted simulations positively assert the validity of the proposed design methodology, emphasizing the exploitable design space yielded by the transistor connection scheme in the voltage multiplier chain. An experimental validation and comparison of threshold-compensation techniques was performed, adopting 2N5247 N-channel junction field effect transistors (JFETs) for the realization of the voltage multiplier prototypes. The attained measurements clearly support the effectiveness of the proposed threshold-reduction approach, which can significantly reduce the chip area occupation for a given target output performance and ac input signal.
Response of pMOS dosemeters on gamma-ray irradiation during its re-use.
Pejovic, Milic M; Pejovic, Momcilo M; Jaksic, Aleksandar B
2013-08-01
Response of pMOS dosemeters during two successive irradiations with gamma-ray irradiation to a dose of 35 Gy and annealing at room and elevated temperature has been studied. The response was followed on the basis of threshold voltage shift, determined from transfer characteristics, as a function of absorbed dose or annealing time. It was shown that the threshold voltage shifts during first and second irradiation for the gate bias during irradiation of 5 and 2.5 V insignificantly differ although complete fading was not achieved after the first cycle of annealing. In order to analyse the defects formed in oxide and at the interface during irradiation and annealing, which are responsible for threshold voltage shift, midgap and charge-pumping techniques were used. It was shown that during first irradiation and annealing a dominant influence to threshold voltage shift is made by fixed oxide traps, while at the beginning of the second annealing cycle, threshold voltage shift is a consequence of both fixed oxide traps and slow switching traps.
NASA Technical Reports Server (NTRS)
Asenov, Asen; Saini, Subhash
2000-01-01
In this paper, we investigate various aspects of the polysilicon gate influence on the random dopant induced threshold voltage fluctuations in sub-100 nm MOSFET's with ultrathin gate oxides. The study is done by using an efficient statistical three-dimensional (3-D) "atomistic" simulation technique described else-where. MOSFET's with uniform channel doping and with low doped epitaxial channels have been investigated. The simulations reveal that even in devices with a single crystal gate the gate depletion and the random dopants in it are responsible for a substantial fraction of the threshold voltage fluctuations when the gate oxide is scaled-in the range of 1-2 nm. Simulation experiments have been used in order to separate the enhancement in the threshold voltage fluctuations due to an effective increase in the oxide thickness associated with the gate depletion from the direct influence of the random dopants in the gate depletion layer. The results of the experiments show that the both factors contribute to the enhancement of the threshold voltage fluctuations, but the effective increase in the oxide-thickness has a dominant effect in the investigated range of devices. Simulations illustrating the effect or the polysilicon grain boundaries on the threshold voltage variation are also presented.
Janardhan, Ajit H; Li, Wenwen; Fedorov, Vadim V; Yeung, Michael; Wallendorf, Michael J; Schuessler, Richard B; Efimov, Igor R
2012-12-11
The authors sought to develop a low-energy electrotherapy that terminates ventricular tachycardia (VT) when antitachycardia pacing (ATP) fails. High-energy implantable cardioverter-defibrillator (ICD) shocks are associated with device failure, significant morbidity, and increased mortality. A low-energy alternative to ICD shocks is desirable. Myocardial infarction was created in 25 dogs. Sustained, monomorphic VT was induced by programmed stimulation. Defibrillation electrodes were placed in the right ventricular apex, and coronary sinus and left ventricular epicardium. If ATP failed to terminate sustained VT, the defibrillation thresholds (DFTs) of standard versus experimental electrotherapies were measured. Sustained VT ranged from 276 to 438 beats/min (mean 339 beats/min). The right ventricular-coronary sinus shock vector had lower impedance than the right ventricular-left ventricular patch (54.4 ± 18.1 Ω versus 109.8 ± 16.9 Ω; p < 0.001). A single shock required between 0.3 ± 0.2 J to 5.9 ± 2.5 J (mean 2.64 ± 3.22 J; p = 0.008) to terminate VT, and varied depending upon the phase of the VT cycle in which it was delivered. By contrast, multiple shocks delivered within 1 VT cycle length were not phase dependent and achieved lower DFT compared with a single shock (0.13 ± 0.09 J for 3 shocks, 0.08 ± 0.04 J for 5 shocks, and 0.09 ± 0.07 J for 7 shocks; p < 0.001). Finally, a multistage electrotherapy (MSE) achieved significantly lower DFT compared with a single biphasic shock (0.03 ± 0.05 J versus 2.37 ± 1.20 J; respectively, p < 0.001). At a peak shock amplitude of 20 V, MSE achieved 91.3% of terminations versus 10.5% for a biphasic shock (p < 0.001). MSE achieved a major reduction in DFT compared with a single biphasic shock for ATP-refractory monomorphic VT, and represents a novel electrotherapy to reduce high-energy ICD shocks. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Threshold voltage control in TmSiO/HfO2 high-k/metal gate MOSFETs
NASA Astrophysics Data System (ADS)
Dentoni Litta, E.; Hellström, P.-E.; Östling, M.
2015-06-01
High-k interfacial layers have been proposed as a way to extend the scalability of Hf-based high-k/metal gate CMOS technology, which is currently limited by strong degradations in threshold voltage control, channel mobility and device reliability when the chemical oxide (SiOx) interfacial layer is scaled below 0.4 nm. We have previously demonstrated that thulium silicate (TmSiO) is a promising candidate as a high-k interfacial layer, providing competitive advantages in terms of EOT scalability and channel mobility. In this work, the effect of the TmSiO interfacial layer on threshold voltage control is evaluated, showing that the TmSiO/HfO2 dielectric stack is compatible with threshold voltage control techniques commonly used with SiOx/HfO2 stacks. Specifically, we show that the flatband voltage can be set in the range -1 V to +0.5 V by the choice of gate metal and that the effective workfunction of the stack is properly controlled by the metal workfunction in a gate-last process flow. Compatibility with a gate-first approach is also demonstrated, showing that integration of La2O3 and Al2O3 capping layers can induce a flatband voltage shift of at least 150 mV. Finally, the effect of the annealing conditions on flatband voltage is investigated, finding that the duration of the final forming gas anneal can be used as a further process knob to tune the threshold voltage. The evaluation performed on MOS capacitors is confirmed by the fabrication of TmSiO/HfO2/TiN MOSFETs achieving near-symmetric threshold voltages at sub-nm EOT.
Separation of β-amyloid binding and white matter uptake of 18F-flutemetamol using spectral analysis
Heurling, Kerstin; Buckley, Christopher; Vandenberghe, Rik; Laere, Koen Van; Lubberink, Mark
2015-01-01
The kinetic components of the β-amyloid ligand 18F-flutemetamol binding in grey and white matter were investigated through spectral analysis, and a method developed for creation of parametric images separating grey and white matter uptake. Tracer uptake in grey and white matter and cerebellar cortex was analyzed through spectral analysis in six subjects, with (n=4) or without (n=2) apparent β-amyloid deposition, having undergone dynamic 18F-flutemetamol scanning with arterial blood sampling. The spectra were divided into three components: slow, intermediate and fast basis function rates. The contribution of each of the components to total volume of distribution (VT) was assessed for different tissue types. The slow component dominated in white matter (average 90%), had a higher contribution to grey matter VT in subjects with β-amyloid deposition (average 44%) than without (average 6%) and was absent in cerebellar cortex, attributing the slow component of 18F-flutemetamol uptake in grey matter to β-amyloid binding. Parametric images of voxel-based spectral analysis were created for VT, the slow component and images segmented based on the slow component contribution; confirming that grey matter and white matter uptake can be discriminated on voxel-level using a threshold for the contribution from the slow component to VT. PMID:26550542
Self-reported tolerance influences prefrontal cortex hemodynamics and affective responses.
Tempest, Gavin; Parfitt, Gaynor
2016-02-01
The relationship between cognitive and sensory processes in the brain contributes to the regulation of affective responses (pleasure-displeasure). Exercise can be used to manipulate sensory processes (by increasing physiological demand) in order to examine the role of dispositional traits that may influence an individual's ability to cognitively regulate these responses. With the use of near infrared spectroscopy, in this study we examined the influence of self-reported tolerance upon prefrontal cortex (PFC) hemodynamics and affective responses. The hemodynamic response was measured in individuals with high or low tolerance during an incremental exercise test. Sensory manipulation was standardized against metabolic processes (ventilatory threshold [VT] and respiratory compensation point [RCP]), and affective responses were recorded. The results showed that the high-tolerance group displayed a larger hemodynamic response within the right PFC above VT (which increased above RCP). The low-tolerance group showed a larger hemodynamic response within the left PFC above VT. The high-tolerance group reported a more positive/less negative affective response above VT. These findings provide direct neurophysiological evidence of differential hemodynamic responses within the PFC that are associated with tolerance in the presence of increased physiological demands. This study supports the role of dispositional traits and previous theorizing into the underlying mechanisms (cognitive vs. sensory processes) of affective responses.
Discharging dynamics in an electrolytic cell
NASA Astrophysics Data System (ADS)
Feicht, Sarah E.; Frankel, Alexandra E.; Khair, Aditya S.
2016-07-01
We analyze the dynamics of a discharging electrolytic cell comprised of a binary symmetric electrolyte between two planar, parallel blocking electrodes. When a voltage is initially applied, ions in the electrolyte migrate towards the electrodes, forming electrical double layers. After the system reaches steady state and the external current decays to zero, the applied voltage is switched off and the cell discharges, with the ions eventually returning to a uniform spatial concentration. At voltages on the order of the thermal voltage VT=kBT /q ≃25 mV, where kB is Boltzmann's constant, T is temperature, and q is the charge of a proton, experiments on surfactant-doped nonpolar fluids observe that the temporal evolution of the external current during charging and discharging is not symmetric [V. Novotny and M. A. Hopper, J. Electrochem. Soc. 126, 925 (1979), 10.1149/1.2129195; P. Kornilovitch and Y. Jeon, J. Appl. Phys. 109, 064509 (2011), 10.1063/1.3554445]. In fact, at sufficiently large voltages (several VT), the current during discharging is no longer monotonic: it displays a "reverse peak" before decaying in magnitude to zero. We analyze the dynamics of discharging by solving the Poisson-Nernst-Planck equations governing ion transport via asymptotic and numerical techniques in three regimes. First, in the "linear regime" when the applied voltage V is formally much less than VT, the charging and discharging currents are antisymmetric in time; however, the potential and charge density profiles during charging and discharging are asymmetric. The current evolution is on the R C timescale of the cell, λDL /D , where L is the width of the cell, D is the diffusivity of ions, and λD is the Debye length. Second, in the (experimentally relevant) thin-double-layer limit ɛ =λD/L ≪1 , there is a "weakly nonlinear" regime defined by VT≲V ≲VTln(1 /ɛ ) , where the bulk salt concentration is uniform; thus the R C timescale of the evolution of the current magnitude persists. However, nonlinear, voltage-dependent, capacitance of the double layer is responsible for a break in temporal antisymmetry of the charging and discharging currents. Third, the reverse peak in the discharging current develops in a "strongly nonlinear" regime V ≳VTln(1 /ɛ ) , driven by neutral salt adsorption into the double layers and consequent bulk depletion during charging. The strongly nonlinear regime features current evolution over three timescales. The current decays in magnitude on the double layer relaxation timescale, λD2/D ; then grows exponentially in time towards the reverse peak on the diffusion timescale, L2/D , indicating that the reverse peak is the results of fast diffusion of ions from the double layer layer to the bulk. Following the reverse peak, the current decays exponentially to zero on the R C timescale. Notably, the current at the reverse peak and the time of the reverse peak saturate at large voltages V ≫VTln(1 /ɛ ) . We provide semi-analytic expressions for the saturated reverse peak time and current, which can be used to infer charge carrier diffusivity and concentration from experiments.
Wang, Huiliang; Wei, Peng; Li, Yaoxuan; Han, Jeff; Lee, Hye Ryoung; Naab, Benjamin D.; Liu, Nan; Wang, Chenggong; Adijanto, Eric; Tee, Benjamin C.-K.; Morishita, Satoshi; Li, Qiaochu; Gao, Yongli; Cui, Yi; Bao, Zhenan
2014-01-01
Tuning the threshold voltage of a transistor is crucial for realizing robust digital circuits. For silicon transistors, the threshold voltage can be accurately controlled by doping. However, it remains challenging to tune the threshold voltage of single-wall nanotube (SWNT) thin-film transistors. Here, we report a facile method to controllably n-dope SWNTs using 1H-benzoimidazole derivatives processed via either solution coating or vacuum deposition. The threshold voltages of our polythiophene-sorted SWNT thin-film transistors can be tuned accurately and continuously over a wide range. Photoelectron spectroscopy measurements confirmed that the SWNT Fermi level shifted to the conduction band edge with increasing doping concentration. Using this doping approach, we proceeded to fabricate SWNT complementary inverters by inkjet printing of the dopants. We observed an unprecedented noise margin of 28 V at VDD = 80 V (70% of 1/2VDD) and a gain of 85. Additionally, robust SWNT complementary metal−oxide−semiconductor inverter (noise margin 72% of 1/2VDD) and logic gates with rail-to-rail output voltage swing and subnanowatt power consumption were fabricated onto a highly flexible substrate. PMID:24639537
Role of AlGaN/GaN interface traps on negative threshold voltage shift in AlGaN/GaN HEMT
NASA Astrophysics Data System (ADS)
Malik, Amit; Sharma, Chandan; Laishram, Robert; Bag, Rajesh Kumar; Rawal, Dipendra Singh; Vinayak, Seema; Sharma, Rajesh Kumar
2018-04-01
This article reports negative shift in the threshold-voltage in AlGaN/GaN high electron mobility transistor (HEMT) with application of reverse gate bias stress. The device is biased in strong pinch-off and low drain to source voltage condition for a fixed time duration (reverse gate bias stress), followed by measurement of transfer characteristics. Negative threshold voltage shift after application of reverse gate bias stress indicates the presence of more carriers in channel as compared to the unstressed condition. We propose the presence of AlGaN/GaN interface states to be the reason of negative threshold voltage shift, and developed a process to electrically characterize AlGaN/GaN interface states. We verified the results with Technology Computer Aided Design (TCAD) ATLAS simulation and got a good match with experimental measurements.
Gas composition sensing using carbon nanotube arrays
NASA Technical Reports Server (NTRS)
Li, Jing (Inventor); Meyyappan, Meyya (Inventor)
2008-01-01
A method and system for estimating one, two or more unknown components in a gas. A first array of spaced apart carbon nanotubes (''CNTs'') is connected to a variable pulse voltage source at a first end of at least one of the CNTs. A second end of the at least one CNT is provided with a relatively sharp tip and is located at a distance within a selected range of a constant voltage plate. A sequence of voltage pulses {V(t.sub.n)}.sub.n at times t=t.sub.n (n=1, . . . , N1; N1.gtoreq.3) is applied to the at least one CNT, and a pulse discharge breakdown threshold voltage is estimated for one or more gas components, from an analysis of a curve I(t.sub.n) for current or a curve e(t.sub.n) for electric charge transported from the at least one CNT to the constant voltage plate. Each estimated pulse discharge breakdown threshold voltage is compared with known threshold voltages for candidate gas components to estimate whether at least one candidate gas component is present in the gas. The procedure can be repeated at higher pulse voltages to estimate a pulse discharge breakdown threshold voltage for a second component present in the gas.
Choi, Tayoung; Ganapathy, Sriram; Jung, Jaehak; Savage, David R.; Lakshmanan, Balasubramanian; Vecasey, Pamela M.
2013-04-16
A system and method for detecting a low performing cell in a fuel cell stack using measured cell voltages. The method includes determining that the fuel cell stack is running, the stack coolant temperature is above a certain temperature and the stack current density is within a relatively low power range. The method further includes calculating the average cell voltage, and determining whether the difference between the average cell voltage and the minimum cell voltage is greater than a predetermined threshold. If the difference between the average cell voltage and the minimum cell voltage is greater than the predetermined threshold and the minimum cell voltage is less than another predetermined threshold, then the method increments a low performing cell timer. A ratio of the low performing cell timer and a system run timer is calculated to identify a low performing cell.
Tao, Qian; Milles, Julien; VAN Huls VAN Taxis, Carine; Lamb, Hildo J; Reiber, Johan H C; Zeppenfeld, Katja; VAN DER Geest, Rob J
2012-01-01
Integration of preprocedural delayed enhanced magnetic resonance imaging (DE-MRI) with electroanatomical voltage mapping (EAVM) may provide additional high-resolution substrate information for catheter ablation of scar-related ventricular tachycardias (VT). Accurate and fast image integration of DE-MRI with EAVM is desirable for MR-guided ablation. Twenty-six VT patients with large transmural scar underwent catheter ablation and preprocedural DE-MRI. With different registration models and EAVM input, 3 image integration methods were evaluated and compared to the commercial registration module CartoMerge. The performance was evaluated both in terms of distance measure that describes surface matching, and correlation measure that describes actual scar correspondence. Compared to CartoMerge, the method that uses the translation-and-rotation model and high-density EAVM input resulted in a registration error of 4.32±0.69 mm as compared to 4.84 ± 1.07 (P <0.05); the method that uses the translation model and high-density EAVM input resulted in a registration error of 4.60 ± 0.65 mm (P = NS); and the method that uses the translation model and a single anatomical landmark input resulted in a registration error of 6.58 ± 1.63 mm (P < 0.05). No significant difference in scar correlation was observed between all 3 methods and CartoMerge (P = NS). During VT ablation procedures, accurate integration of EAVM and DE-MRI can be achieved using a translation registration model and a single anatomical landmark. This model allows for image integration in minimal mapping time and is likely to reduce fluoroscopy time and increase procedure efficacy. © 2011 Wiley Periodicals, Inc.
Crothers, James M; Forte, John G; Machen, Terry E
2016-05-01
A computer model, constructed for evaluation of integrated functioning of cellular components involved in acid secretion by the gastric parietal cell, has provided new interpretations of older experimental evidence, showing the functional significance of a canalicular space separated from a mucosal bath by a gland lumen and also shedding light on basolateral Cl(-) transport. The model shows 1) changes in levels of parietal cell secretion (with stimulation or H-K-ATPase inhibitors) result mainly from changes in electrochemical driving forces for apical K(+) and Cl(-) efflux, as canalicular [K(+)] ([K(+)]can) increases or decreases with changes in apical H(+)/K(+) exchange rate; 2) H-K-ATPase inhibition in frog gastric mucosa would increase [K(+)]can similarly with low or high mucosal [K(+)], depolarizing apical membrane voltage similarly, so electrogenic H(+) pumping is not indicated by inhibition causing similar increase in transepithelial potential difference (Vt) with 4 and 80 mM mucosal K(+); 3) decreased H(+) secretion during strongly mucosal-positive voltage clamping is consistent with an electroneutral H-K-ATPase being inhibited by greatly decreased [K(+)]can (Michaelis-Menten mechanism); 4) slow initial change ("long time-constant transient") in current or Vt with clamping of Vt or current involves slow change in [K(+)]can; 5) the Na(+)-K(+)-2Cl(-) symporter (NKCC) is likely to have a significant role in Cl(-) influx, despite evidence that it is not necessary for acid secretion; and 6) relative contributions of Cl(-)/HCO3 (-) exchanger (AE2) and NKCC to Cl(-) influx would differ greatly between resting and stimulated states, possibly explaining reported differences in physiological characteristics of stimulated open-circuit Cl(-) secretion (≈H(+)) and resting short-circuit Cl(-) secretion (>H(+)). Copyright © 2016 the American Physiological Society.
Differences in Pedaling Technique in Cycling: A Cluster Analysis.
Lanferdini, Fábio J; Bini, Rodrigo R; Figueiredo, Pedro; Diefenthaeler, Fernando; Mota, Carlos B; Arndt, Anton; Vaz, Marco A
2016-10-01
To employ cluster analysis to assess if cyclists would opt for different strategies in terms of neuromuscular patterns when pedaling at the power output of their second ventilatory threshold (PO VT2 ) compared with cycling at their maximal power output (PO MAX ). Twenty athletes performed an incremental cycling test to determine their power output (PO MAX and PO VT2 ; first session), and pedal forces, muscle activation, muscle-tendon unit length, and vastus lateralis architecture (fascicle length, pennation angle, and muscle thickness) were recorded (second session) in PO MAX and PO VT2 . Athletes were assigned to 2 clusters based on the behavior of outcome variables at PO VT2 and PO MAX using cluster analysis. Clusters 1 (n = 14) and 2 (n = 6) showed similar power output and oxygen uptake. Cluster 1 presented larger increases in pedal force and knee power than cluster 2, without differences for the index of effectiveness. Cluster 1 presented less variation in knee angle, muscle-tendon unit length, pennation angle, and tendon length than cluster 2. However, clusters 1 and 2 showed similar muscle thickness, fascicle length, and muscle activation. When cycling at PO VT2 vs PO MAX , cyclists could opt for keeping a constant knee power and pedal-force production, associated with an increase in tendon excursion and a constant fascicle length. Increases in power output lead to greater variations in knee angle, muscle-tendon unit length, tendon length, and pennation angle of vastus lateralis for a similar knee-extensor activation and smaller pedal-force changes in cyclists from cluster 2 than in cluster 1.
Wester, Jason C.
2013-01-01
Spike threshold filters incoming inputs and thus gates activity flow through neuronal networks. Threshold is variable, and in many types of neurons there is a relationship between the threshold voltage and the rate of rise of the membrane potential (dVm/dt) leading to the spike. In primary sensory cortex this relationship enhances the sensitivity of neurons to a particular stimulus feature. While Na+ channel inactivation may contribute to this relationship, recent evidence indicates that K+ currents located in the spike initiation zone are crucial. Here we used a simple Hodgkin-Huxley biophysical model to systematically investigate the role of K+ and Na+ current parameters (activation voltages and kinetics) in regulating spike threshold as a function of dVm/dt. Threshold was determined empirically and not estimated from the shape of the Vm prior to a spike. This allowed us to investigate intrinsic currents and values of gating variables at the precise voltage threshold. We found that Na+ inactivation is sufficient to produce the relationship provided it occurs at hyperpolarized voltages combined with slow kinetics. Alternatively, hyperpolarization of the K+ current activation voltage, even in the absence of Na+ inactivation, is also sufficient to produce the relationship. This hyperpolarized shift of K+ activation allows an outward current prior to spike initiation to antagonize the Na+ inward current such that it becomes self-sustaining at a more depolarized voltage. Our simulations demonstrate parameter constraints on Na+ inactivation and the biophysical mechanism by which an outward current regulates spike threshold as a function of dVm/dt. PMID:23344915
Specific features of a single-pulse sliding discharge in neon near the threshold for spark breakdown
NASA Astrophysics Data System (ADS)
Trusov, K. K.
2017-08-01
Experimental data on the spatial structure of a single-pulse sliding discharge in neon at voltages below, equal to, and above the threshold for spark breakdown are discussed. The experiments were carried at gas pressures of 30 and 100 kPa and different polarities of the discharge voltage. Photographs of the plasma structure in two discharge chambers with different dimensions of the discharge zone and different thicknesses of an alumina dielectric plate on the surface of which the discharge develops are inspected. Common features of the prebreakdown discharge and its specific features depending on the voltage polarity and gas pressure are analyzed. It is shown that, at voltages below the threshold for spark breakdown, a low-current glow discharge with cathode and anode spots develops in the electrode gap. Above the breakdown threshold, regardless of the voltage polarity, spark channels directed from the cathode to the anode develop against the background of a low-current discharge.
Cardiorespiratory demands during an inline speed skating marathon race: a case report.
Stangier, Carolin; Abel, Thomas; Mierau, Julia; Hollmann, Wildor; Strüder, Heiko K
2016-09-01
This study was designed to investigate the intensity profile during an inline speed skating marathon road race. A highly-trained male athlete (20 y, 73.4 kg, 178 cm, V̇O2 peak: 60.8 mL·kg-1·min-1) participated in a marathon road race. Oxygen uptake (V̇O2), respiratory exchange ratio (RER), heart rate (HR) and speed were measured using a portable gas analysis system with a HR monitor and GPS-Sensor integrated. The athlete´s peak V̇O2, HR and speed at ventilatory thresholds were assessed during an incremental field test (22 km·h-1, increase 2 km·h-1 every 5 min) one week before the race. During the race, the absolute time spent in the "easy intensity zone" (V̇O2 below VT1) was 1 min, 49 min "moderate intensity zone" (V̇O2 between VT1 and VT2), and 26 min in the "hard intensity zone" (V̇O2 above VT2). The average HR was 171±6 bpm, corresponding to 95% of the maximum. This study shows that inline speed skating road races over a marathon are conducted at moderate to high V̇O2 and heart rate levels. The physiological racing pattern is very intermittent, requiring both a high level of aerobic and anaerobic capacity.
NASA Technical Reports Server (NTRS)
Asenov, Asen; Slavcheva, G.; Brown, A. R.; Davies, J. H.; Saini, S.
2000-01-01
In this paper we present a detailed simulation study of the influence of quantum mechanical effects in the inversion layer on random dopant induced threshold voltage fluctuations and lowering in sub 100 nm MOSFETs. The simulations have been performed using a 3-D implementation of the density gradient (DG) formalism incorporated in our established 3-D atomistic simulation approach. This results in a self-consistent 3-D quantum mechanical picture, which implies not only the vertical inversion layer quantisation but also the lateral confinement effects related to current filamentation in the 'valleys' of the random potential fluctuations. We have shown that the net result of including quantum mechanical effects, while considering statistical dopant fluctuations, is an increase in both threshold voltage fluctuations and lowering. At the same time, the random dopant induced threshold voltage lowering partially compensates for the quantum mechanical threshold voltage shift in aggressively scaled MOSFETs with ultrathin gate oxides.
Gas Composition Sensing Using Carbon Nanotube Arrays
NASA Technical Reports Server (NTRS)
Li, Jing; Meyyappan, Meyya
2012-01-01
This innovation is a lightweight, small sensor for inert gases that consumes a relatively small amount of power and provides measurements that are as accurate as conventional approaches. The sensing approach is based on generating an electrical discharge and measuring the specific gas breakdown voltage associated with each gas present in a sample. An array of carbon nanotubes (CNTs) in a substrate is connected to a variable-pulse voltage source. The CNT tips are spaced appropriately from the second electrode maintained at a constant voltage. A sequence of voltage pulses is applied and a pulse discharge breakdown threshold voltage is estimated for one or more gas components, from an analysis of the current-voltage characteristics. Each estimated pulse discharge breakdown threshold voltage is compared with known threshold voltages for candidate gas components to estimate whether at least one candidate gas component is present in the gas. The procedure can be repeated at higher pulse voltages to estimate a pulse discharge breakdown threshold voltage for a second component present in the gas. The CNTs in the gas sensor have a sharp (low radius of curvature) tip; they are preferably multi-wall carbon nanotubes (MWCNTs) or carbon nanofibers (CNFs), to generate high-strength electrical fields adjacent to the tips for breakdown of the gas components with lower voltage application and generation of high current. The sensor system can provide a high-sensitivity, low-power-consumption tool that is very specific for identification of one or more gas components. The sensor can be multiplexed to measure current from multiple CNT arrays for simultaneous detection of several gas components.
Macananey, Oscar; O'Shea, Donal; Warmington, Stuart A; Green, Simon; Egaña, Mikel
2012-08-01
Supervised exercise (SE) in patients with type 2 diabetes improves oxygen uptake kinetics at the onset of exercise. Maintenance of these improvements, however, has not been examined when supervision is removed. We explored if potential improvements in oxygen uptake kinetics following a 12-week SE that combined aerobic and resistance training were maintained after a subsequent 12-week unsupervised exercise (UE). The involvement of cardiac output (CO) in these improvements was also tested. Nineteen volunteers with type 2 diabetes were recruited. Oxygen uptake kinetics and CO (inert gas rebreathing) responses to constant-load cycling at 50% ventilatory threshold (V(T)), 80% V(T), and mid-point between V(T) and peak workload (50% Δ) were examined at baseline (on 2 occasions) and following each 12-week training period. Participants decided to exercise at a local gymnasium during the UE. Thirteen subjects completed all the interventions. The time constant of phase 2 of oxygen uptake was significantly faster (p < 0.05) post-SE and post-UE compared with baseline at 50% V(T) (17.3 ± 10.7 s and 17.5 ± 5.9 s vs. 29.9 ± 10.7 s), 80% V(T) (18.9 ± 4.7 and 20.9 ± 8.4 vs. 34.3 ± 12.7s), and 50% Δ (20.4 ± 8.2 s and 20.2 ± 6.0 s vs. 27.6 ± 3.7 s). SE also induced faster heart rate kinetics at all 3 intensities and a larger increase in CO at 30 s in relation to 240 s at 80% V(T); and these responses were maintained post-UE. Unsupervised exercise maintained benefits in oxygen uptake kinetics obtained during a supervised exercise in subjects with diabetes, and these benefits were associated with a faster dynamic response of heart rate after training.
Tennis Play Intensity Distribution and Relation with Aerobic Fitness in Competitive Players
Baiget, Ernest; Fernández-Fernández, Jaime; Iglesias, Xavier; Rodríguez, Ferran A.
2015-01-01
The aims of this study were (i) to describe the relative intensity of simulated tennis play based on the cumulative time spent in three metabolic intensity zones, and (ii) to determine the relationships between this play intensity distribution and the aerobic fitness of a group of competitive players. 20 male players of advanced to elite level (ITN) performed an incremental on-court specific endurance tennis test to exhaustion to determine maximal oxygen uptake (VO2max) and the first and second ventilatory thresholds (VT1, VT2). Ventilatory and gas exchange parameters were monitored using a telemetric portable gas analyser (K4 b2, Cosmed, Rome, Italy). Two weeks later the participants played a simulated tennis set against an opponent of similar level. Intensity zones (1: low, 2: moderate, and 3: high) were delimited by the individual VO2 values corresponding to VT1 and VT2, and expressed as percentage of maximum VO2 and heart rate. When expressed relative to VO2max, percentage of playing time in zone 1 (77 ± 25%) was significantly higher (p < 0.001) than in zone 2 (20 ± 21%) and zone 3 (3 ± 5%). Moderate to high positive correlations were found between VT1, VT2 and VO2max, and the percentage of playing time spent in zone 1 (r = 0.68–0.75), as well as low to high inverse correlations between the metabolic variables and the percentage of time spent in zone 2 and 3 (r = -0.49–0.75). Players with better aerobic fitness play at relatively lower intensities. We conclude that players spent more than 75% of the time in their low-intensity zone, with less than 25% of the time spent at moderate to high intensities. Aerobic fitness appears to determine the metabolic intensity that players can sustain throughout the game. PMID:26098638
Schaun, Gustavo Z; Pinto, Stephanie S; Silva, Mariana R; Dolinski, Davi B; Alberton, Cristine L
2018-05-07
Schaun, GZ, Pinto, SS, Silva, MR, Dolinski, DB, and Alberton, CL. Sixteen weeks of whole-body high-intensity interval training induce similar cardiorespiratory responses compared with traditional high-intensity interval training and moderate-intensity continuous training in healthy men. J Strength Cond Res XX(X): 000-000, 2018-Low-volume high-intensity interval training (HIIT) protocols that use the body weight as resistance could be an interesting and inexpensive alternative to traditional ergometer-based high-intensity interval training (HIIT-T) and moderate-intensity continuous training (MICT). Therefore, our aim was to compare the effects of 16 weeks of whole-body HIIT (HIIT-WB), HIIT-T, and MICT on maximal oxygen uptake (V[Combining Dot Above]O2max), second ventilatory threshold (VT2), and running economy (RE) outcomes. Fifty-five healthy men (23.7 ± 0.7 years, 1.79 ± 0.01 m, 78.5 ± 1.7 kg) were randomized into 3 training groups (HIIT-T = 17; HIIT-WB = 19; MICT = 19) for 16 weeks (3× per week). The HIIT-T group performed eight 20-second bouts at 130% of the velocity associated to V[Combining Dot Above]O2max (vV[Combining Dot Above]O2max) interspersed by 10-second passive recovery on a treadmill, whereas HIIT-WB group performed the same protocol but used calisthenics exercises at an all-out intensity instead of treadmill running. Finally, MICT group exercised for 30 minutes at 90-95% of the heart rate (HR) associated to VT2. After the intervention, all groups improved V[Combining Dot Above]O2max, vV[Combining Dot Above]O2max, time to exhaustion (Tmax), VT2, velocity associated with VT2 (vVT2), and time to reach VT2 (tVT2) significantly (p < 0.05). Moreover, Tmax, vVT2, and tVT2 were greater after HIIT-T compared with HIIT-WB (p < 0.05), whereas oxygen uptake increased and HR decreased during the RE test in all groups (p < 0.05). Our results demonstrate that HIIT-WB can be as effective as traditional HIIT while also being time-efficient compared with MICT to improve health-related outcomes after 16 weeks of training. However, HIIT-T and MICT seem preferable to enhance performance-related outcomes compared with HIIT-WB.
NASA Technical Reports Server (NTRS)
Asenov, Asen; Saini, Subhash
1999-01-01
A detailed three-dimensional (3-D) statistical 'atomistic' simulation study of fluctuation-resistant sub-0.1-(micron)meter MOSFET architectures with epitaxial channels and delta doping is presented. The need for enhancing the fluctuation resistance of the sub-0.1-(micron)meter generation transistors is highlighted by presenting summarized results from atomistic simulations of a wide range of conventional devices with uniformly doped channel. According to our atomistic results, the doping concentration dependence of the random dopant-induced threshold voltage fluctuations in conventional devices is stronger than the analytically predicted fourth-root dependence. As a result of this, the scaling of such devices will be restricted by the "intrinsic" random dopant-induced fluctuations earlier than anticipated. Our atomistic simulations confirm that the introduction of a thin epitaxial layer in the MOSFET's channel can efficiently suppress the random dopant-induced threshold voltage fluctuations in sub-0.1-(micron)meter devices. For the first time, we observe an "anomalous" reduction in the threshold voltage fluctuations with an increase in the doping concentration behind the epitaxial channel, which we attribute to screening effects. Also, for the first time we study the effect of a delta-doping, positioned behind the epitaxial layer, on the intrinsic threshold voltage fluctuations. Above a certain thickness of epitaxial layer, we observe a pronounced anomalous decrease in the threshold voltage fluctuation with the increase of the delta doping. This phenomenon, which is also associated with screening, enhances the importance of the delta doping in the design of properly scaled fluctuation-resistant sub-0.1-(micron)meter MOSFET's. Index Terms-Doping, fluctuations, MOSFET, semiconductor device simulation, silicon devices, threshold.
NASA Astrophysics Data System (ADS)
Lin, Yu-Ta; Ker, Ming-Dou; Wang, Tzu-Ming
2011-03-01
A new on-panel readout circuit with threshold voltage compensation for capacitive sensor in low temperature polycrystalline silicon (poly-Si) thin-film transistor (LTPS-TFT) process has been proposed. In order to compensate the threshold voltage variation from LTPS process variation, the proposed readout circuit applies a novel compensation approach with switch capacitor technique. In addition, a 4-bit analog-to-digital converter (ADC) is added to identify different sensed capacitor values and further enhances the overall resolution of touch panel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Kuan-Hsien; Chou, Wu-Ching, E-mail: tcchang3708@gmail.com, E-mail: wuchingchou@mail.nctu.edu.tw; Chang, Ting-Chang, E-mail: tcchang3708@gmail.com, E-mail: wuchingchou@mail.nctu.edu.tw
2014-10-21
This paper investigates abnormal dimension-dependent thermal instability in amorphous indium-gallium-zinc-oxide (a-IGZO) thin-film transistors. Device dimension should theoretically have no effects on threshold voltage, except for in short channel devices. Unlike short channel drain-induced source barrier lowering effect, threshold voltage increases with increasing drain voltage. Furthermore, for devices with either a relatively large channel width or a short channel length, the output drain current decreases instead of saturating with an increase in drain voltage. Moreover, the wider the channel and the shorter the channel length, the larger the threshold voltage and output on-state current degradation that is observed. Because of themore » surrounding oxide and other thermal insulating material and the low thermal conductivity of the IGZO layer, the self-heating effect will be pronounced in wider/shorter channel length devices and those with a larger operating drain bias. To further clarify the physical mechanism, fast I{sub D}-V{sub G} and modulated peak/base pulse time I{sub D}-V{sub D} measurements are utilized to demonstrate the self-heating induced anomalous dimension-dependent threshold voltage variation and on-state current degradation.« less
Effects of Endurance Training at the Crossover Point in Women with Metabolic Syndrome.
Borel, Benoit; Coquart, Jérémy; Boitel, Guillaume; Duhamel, Alain; Matran, Régis; Delsart, Pascal; Mounier-Vehier, Claire; Garcin, Murielle
2015-11-01
On the basis of theoretical evidence, intensity at the crossover point (COP) of substrate utilization could be considered as potential exercise intensity for metabolic syndrome (MetS). This study aimed to examine the effects of a training program at COP on exercise capacity parameters in women with MetS and to compare two metabolic indices (COP and the maximal fat oxidation rate point LIPOXmax®) with ventilatory threshold (VT). Nineteen women with MetS volunteered to perform a 12-wk training program on a cycle ergometer, with intensity corresponding to COP. Pre- and posttraining values of anthropometric and exercise capacity parameters were compared to determine the effects of exercise training. The pre-post training change of COP, LIPOXmax®, and VT were also investigated. After training, anthropometric parameters were significantly modified, with reduction of body mass (3.0% ± 3.0%, P < 0.001), fat mass (3.3% ± 3.4%, P < 0.001), and body mass index (3.2% ± 3.4%, P < 0.001). Exercise capacity was improved after the training program, with significant increase of maximal power output (25.0% ± 18.4%, P < 0.001) and maximal oxygen uptake (V˙O2max, 9.0% ± 11.2%; P < 0.01). Lastly, when expressed in terms of power output, COP, LIPOXmax®, and VT occurred at a similar exercise intensity, but the occurrence of these three indices is different when expressed in terms of oxygen uptake, HR, or RPE. This study highlights the effectiveness of a 12-wk training program at COP to improve physical fitness in women with MetS. The relations between metabolic indices and VT in terms of power output highlight the determination of VT from a shorter maximal exercise as a useful method for determining metabolic indices in MetS.
NASA Astrophysics Data System (ADS)
Samba, R.; Herrmann, T.; Zeck, G.
2015-02-01
Objective. The aim of this study was to compare two different microelectrode materials—the conductive polymer composite poly-3,4-ethylenedioxythiophene (PEDOT)-carbon nanotube(CNT) and titanium nitride (TiN)—at activating spikes in retinal ganglion cells in whole mount rat retina through stimulation of the local retinal network. Stimulation efficacy of the microelectrodes was analyzed by comparing voltage, current and transferred charge at stimulation threshold. Approach. Retinal ganglion cell spikes were recorded by a central electrode (30 μm diameter) in the planar grid of an electrode array. Extracellular stimulation (monophasic, cathodic, 0.1-1.0 ms) of the retinal network was performed using constant voltage pulses applied to the eight surrounding electrodes. The stimulation electrodes were equally spaced on the four sides of a square (400 × 400 μm). Threshold voltage was determined as the pulse amplitude required to evoke network-mediated ganglion cell spiking in a defined post stimulus time window in 50% of identical stimulus repetitions. For the two electrode materials threshold voltage, transferred charge at threshold, maximum current and the residual current at the end of the pulse were compared. Main results. Stimulation of retinal interneurons using PEDOT-CNT electrodes is achieved with lower stimulation voltage and requires lower charge transfer as compared to TiN. The key parameter for effective stimulation is a constant current over at least 0.5 ms, which is obtained by PEDOT-CNT electrodes at lower stimulation voltage due to its faradaic charge transfer mechanism. Significance. In neuroprosthetic implants, PEDOT-CNT may allow for smaller electrodes, effective stimulation in a safe voltage regime and lower energy-consumption. Our study also indicates, that the charge transferred at threshold or the charge injection capacity per se does not determine stimulation efficacy.
Low Threshold Voltage Continuous Wave Vertical-Cavity Surface-Emitting Lasers
1993-04-26
Data are presented demonstrating a design and fabrication process for the realization of low- threshold , high-output vertical-cavity surface-emitting...layers), the low series resistance of the design results in a bias voltage on o 1.8 V at a threshold current of 1.9 mA for 10-micrometer-diam devices.... Vertical-cavity surface-emitting lasers.
Day, John D; Doshi, Rahul N; Belott, Peter; Birgersdotter-Green, Ulrika; Behboodikhah, Mahnaz; Ott, Peter; Glatter, Kathryn A; Tobias, Serge; Frumin, Howard; Lee, Byron K; Merillat, John; Wiener, Isaac; Wang, Samuel; Grogin, Harlan; Chun, Sung; Patrawalla, Rob; Crandall, Brian; Osborn, Jeffrey S; Weiss, J Peter; Lappe, Donald L; Neuman, Stacey
2007-05-08
Implantable cardioverter-defibrillators and cardiac resynchronization therapy defibrillators have relied on multiple ventricular fibrillation (VF) induction/defibrillation tests at implantation to ensure that the device can reliably sense, detect, and convert VF. The ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations) is the first large, multicenter, prospective trial comparing vulnerability safety margin testing versus defibrillation safety margin testing with a single VF induction/defibrillation. A total of 426 patients receiving an implantable cardioverter-defibrillator or cardiac resynchronization therapy defibrillator underwent vulnerability safety margin or defibrillation safety margin screening at 14 J in a randomized order. After this, patients underwent confirmatory testing, which required 2 VF conversions without failure at < or = 21 J. Patients who passed their first 14-J and confirmatory tests, irrespective of the results of their second 14-J test, had their devices programmed to a 21-J shock for ventricular tachycardia (VT) or VF > or = 200 bpm and were followed up for 1 year. Of 420 patients who underwent 14-J vulnerability safety margin screening, 322 (76.7%) passed. Of these, 317 (98.4%) also passed 21-J confirmatory tests. Of 416 patients who underwent 14-J defibrillation safety margin screening, 343 (82.5%) passed, and 338 (98.5%) also passed 21-J confirmatory tests. Most clinical VT/VF episodes (32 of 37, or 86%) were terminated by the first shock, with no difference in first shock success. In all observed cases in which the first shock was unsuccessful, subsequent shocks terminated VT/VF without complication. Although spontaneous episodes of fast VT/VF were limited, there was no difference in the odds of first shock efficacy between groups. Screening with vulnerability safety margin or defibrillation safety margin may allow for inductionless or limited shock testing in most patients.
Electrically controllable liquid crystal random lasers below the Fréedericksz transition threshold.
Lee, Chia-Rong; Lin, Jia-De; Huang, Bo-Yuang; Lin, Shih-Hung; Mo, Ting-Shan; Huang, Shuan-Yu; Kuo, Chie-Tong; Yeh, Hui-Chen
2011-01-31
This investigation elucidates for the first time electrically controllable random lasers below the threshold voltage in dye-doped liquid crystal (DDLC) cells with and without adding an azo-dye. Experimental results show that the lasing intensities and the energy thresholds of the random lasers can be decreased and increased, respectively, by increasing the applied voltage below the Fréedericksz transition threshold. The below-threshold-electric-controllability of the random lasers is attributable to the effective decrease of the spatial fluctuation of the orientational order and thus of the dielectric tensor of LCs by increasing the electric-field-aligned order of LCs below the threshold, thereby increasing the diffusion constant and decreasing the scattering strength of the fluorescence photons in their recurrent multiple scattering. This can result in the decrease in the lasing intensity of the random lasers and the increase in their energy thresholds. Furthermore, the addition of an azo-dye in DDLC cell can induce the range of the working voltage below the threshold for the control of the random laser to reduce.
Memory formation and evolution of the vortex configuration associated with random organization
NASA Astrophysics Data System (ADS)
Dobroka, M.; Kawamura, Y.; Ienaga, K.; Kaneko, S.; Okuma, S.
2017-05-01
We study the general phenomenon of random organization using a vortex system. When a periodic shear with a small shear amplitude d inp is applied to many-particle (vortex) assemblies with a random distribution, the particles (vortices) gradually self-organize to avoid future collisions and transform into an organized configuration. This is detected from the time-evolution of the voltage V(t) (average velocity) that increases towards a steady-state value. From the subsequent readout measurements of V(t) using various shear amplitudes, we find that the information of the input shear amplitude d inp is memorized in the configuration of the vortex distributions in the transient as well as the steady state, and that it is readable. We also find that the transient vortex configuration formed during random organization is not microscopically homogeneous but consists of disordered and organized regions.
Astorino, Todd A; deRevere, Jamie; Anderson, Theodore; Kellogg, Erin; Holstrom, Patrick; Ring, Sebastian; Ghaseb, Nicholas
2018-06-19
Completion of high-intensity interval training (HIIT) leads to significant increases in maximal oxygen uptake (VO 2max ) and oxidative capacity. However, individual responses to HIIT have been identified as approximately 20-40% of individuals show no change in VO 2max , which may be due to the relatively homogeneous approach to implementing HIIT. This study tested the effects of HIIT prescribed using ventilatory threshold (VT) on changes in VO 2max and cycling performance. Fourteen active men and women (age and VO 2max = 27 ± 8 year and 38 ± 4 mL/kg/min) underwent nine sessions of HIIT, and 14 additional men and women (age and VO 2max = 22 ± 3 year and 40 ± 5 mL/kg/min) served as controls. Training was performed on a cycle ergometer at a work rate equal to 130%VT and consisted of eight to ten 1 min bouts interspersed with 75 s of recovery. At baseline and post-testing, they completed progressive cycling to exhaustion to determine VO 2max , and on a separate day, a 5 mile cycling time trial. Compared to the control group, HIIT led to significant increases in VO 2max (6%, p = 0.007), cycling performance (2.5%, p = 0.003), and absolute VT (9 W, p = 0.005). However, only 57% of participants revealed meaningful increases in VO 2max and cycling performance in response to training, and two showed no change in either outcome. A greater volume of HIIT may be needed to maximize the training response for all individuals.
Pinto, Stephanie S; Brasil, Roxana M; Alberton, Cristine L; Ferreira, Hector K; Bagatini, Natália C; Calatayud, Joaquin; Colado, Juan C
2016-02-01
This study compared heart rate (HR), oxygen uptake (VO2), percentage of maximal HR (%HRmax), percentage of maximal VO2, and cadence (Cad) related to the anaerobic threshold (AT) during a water cycling maximal test between heart rate deflection point (HRDP) and ventilatory (VT) methods. In addition, the correlations between both methods were assessed for all variables. The test was performed by 27 men in a cycle ergometer in an aquatic environment. The protocol started at a Cad of 100 b · min(-1) for 3 minutes with subsequent increments of 15 b · min(-1) every 2 minutes until exhaustion. A paired two-tailed Student's t-test was used to compare the variables between the HRDP and VT methods. The Pearson product-moment correlation test was used to correlate the same variables determined by the 2 methods. There was no difference in HR (166 ± 13 vs. 166 ± 13 b · min(-1)), VO2 (38.56 ± 6.26 vs. 39.18 ± 6.13 ml · kg(-1) · min(-1)), %HRmax (89.24 ± 3.84 vs. 89.52 ± 4.29%), VO2max (70.44 ± 7.99 vs. 71.64 ± 8.32%), and Cad (174 ± 14 b · min(-1) vs. 171 ± 8 b · min(-1)) related to AT between the HRDP and VT methods. Moreover, significant relationships were found between the methods to determine the AT for all variables analyzed (r = 0.57-0.97). The estimation of the HRDP may be a noninvasive and easy method to determine the AT, which could be used to adapt individualized training intensities to practitioners during water cycling classes.
The voltage threshold for arcing for solar cells in Leo - Flight and ground test results
NASA Technical Reports Server (NTRS)
Ferguson, Dale C.
1986-01-01
Ground and flight results of solar cell arcing in low earth orbit (LEO) conditions are compared and interpreted. It is shown that an apparent voltage threshold for arcing may be produced by a storage power law dependence of arc rate on voltage, combined with a limited observation time. The change in this apparent threshold with plasma density is a reflection of the density dependence of the arc rate. A nearly linear dependence of arc rate on density is inferred from the data. A real voltage threshold for arcing for 2 by 2 cm solar cells may exist however, independent of plasma density, near -230 V relative to the plasma. Here, arc rates may change by more than an order of magnitude for a change of only 30 V in array potential. For 5.9 by 5.9 solar cells, the voltage dependence of the arc rate is steeper, and the data are insufficient to indicate the existence of an arcing increased by an atomic oxygen plasma, as is found in LEO, and by arcing from the backs of welded-through substrates.
The voltage threshold for arcing for solar cells in LEO: Flight and ground test results
NASA Technical Reports Server (NTRS)
Ferguson, D. C.
1986-01-01
Ground and flight results of solar cell arcing in low Earth orbit (LEO) conditions are compared and interpreted. It is shown that an apparent voltage threshold for arcing may be produced by a strong power law dependence of arc rate on voltage, combined with a limited observation time. The change in this apparent threshold with plasma density is a reflection of the density dependence of the arc rate. A nearly linear dependence of arc rate on density is inferred from the data. A real voltage threshold for arcing for 2 by 2 cm solar cells may exist however, independent of plasma density, near -230 V relative to the plasma. Here, arc rates may change by more than an order of magnitude for a change of only 30 V in array potential. For 5.9 by 5.9 solar cells, the voltage dependence of the arc rate is steeper, and the data are insufficient to indicate the existence of an arcing increased by an atomic oxygen plasma, as is found in LEO, and by arcing from the backs of welded-through substrates.
Effect of ferroelectric BaTiO3 particles on the threshold voltage of a smectic A liquid crystal.
Imamaliyev, Abbas Rahim; Ramazanov, Mahammadali Ahmad; Humbatov, Shirkhan Arastun
2018-01-01
The influence of small ferroelectric BaTiO 3 particles on the planar-homeotropic transition threshold voltage in smectic A liquid crystals consisting of p -nitrophenyl p -decyloxybenzoate and 4-cyano-4'-pentylbiphenyl were studied by using capacitance-voltage ( C - V ) measurements. It was shown that the BaTiO 3 particles significantly reduce the threshold voltage. The obtained result is explained by two factors: an increase of dielectric anisotropy of the liquid crystals and the formation of a strong electric field near polarized particles of BaTiO 3 . It was shown that the role of the second factor is dominant. The explanations of some features observed in the C - V characteristics are given.
NASA Astrophysics Data System (ADS)
Ching-Lin Fan,; Hui-Lung Lai,; Jyu-Yu Chang,
2010-05-01
In this paper, we propose a novel pixel design and driving method for active-matrix organic light-emitting diode (AM-OLED) displays using low-temperature polycrystalline silicon thin-film transistors (LTPS-TFTs). The proposed threshold voltage compensation circuit, which comprised five transistors and two capacitors, has been verified to supply uniform output current by simulation work using the automatic integrated circuit modeling simulation program with integrated circuit emphasis (AIM-SPICE) simulator. The driving scheme of this voltage programming method includes four periods: precharging, compensation, data input, and emission. The simulated results demonstrate excellent properties such as low error rate of OLED anode voltage variation (<1%) and high output current. The proposed pixel circuit shows high immunity to the threshold voltage deviation characteristics of both the driving poly-Si TFT and the OLED.
NASA Astrophysics Data System (ADS)
Ching-Lin Fan,; Yi-Yan Lin,; Jyu-Yu Chang,; Bo-Jhang Sun,; Yan-Wei Liu,
2010-06-01
This study presents one novel compensation pixel design and driving method for active matrix organic light-emitting diode (AMOLED) displays that use low-temperature polycrystalline silicon thin-film transistors (LTPS-TFTs) with a voltage feed-back method and the simulation results are proposed and verified by SPICE simulator. The measurement and simulation of LTPS TFT characteristics demonstrate the good fitting result. The proposed circuit consists of four TFTs and two capacitors with an additional signal line. The error rates of OLED anode voltage variation are below 0.3% under the threshold voltage deviation of driving TFT (Δ VTH = ± 0.33 V). The simulation results show that the pixel design can improve the display image non-uniformity by compensating the threshold voltage deviation of driving TFT and the degradation of OLED threshold voltage at the same time.
NASA Astrophysics Data System (ADS)
Fan, Ching-Lin; Lin, Yi-Yan; Chang, Jyu-Yu; Sun, Bo-Jhang; Liu, Yan-Wei
2010-06-01
This study presents one novel compensation pixel design and driving method for active matrix organic light-emitting diode (AMOLED) displays that use low-temperature polycrystalline silicon thin-film transistors (LTPS-TFTs) with a voltage feed-back method and the simulation results are proposed and verified by SPICE simulator. The measurement and simulation of LTPS TFT characteristics demonstrate the good fitting result. The proposed circuit consists of four TFTs and two capacitors with an additional signal line. The error rates of OLED anode voltage variation are below 0.3% under the threshold voltage deviation of driving TFT (ΔVTH = ±0.33 V). The simulation results show that the pixel design can improve the display image non-uniformity by compensating the threshold voltage deviation of driving TFT and the degradation of OLED threshold voltage at the same time.
Durkalec-Michalski, Krzysztof; Jeszka, Jan
2016-09-01
Durkalec-Michalski, K and Jeszka, J. The effect of β-hydroxy-β-methylbutyrate on aerobic capacity and body composition in trained athletes. J Strength Cond Res 30(9): 2617-2626, 2016-The aim of this study was to investigate whether supplementation with β-hydroxy-β-methylbutyrate (HMB) affects body composition, aerobic capacity, or intramuscular enzymes activity, as well as in anabolic and/or catabolic hormones and lactate concentrations. A cohort of 58 highly trained males was subjected to 12-week supplementation with HMB (3 × 1 gHMB·d) and a placebo (PLA) in randomized, PLA controlled, double-blind crossover trials, with a 10-day washout period. Body composition and aerobic capacity were recorded, whereas the levels of creatine kinase, lactate dehydrogenase, testosterone, cortisol, and lactate, as well as the T/C ratio, in blood samples were measured. After HMB supplementation, fat-free mass increased (+0.2 kgHMB vs. -1.0 kgPLA, p = 0.021), with a simultaneous reduction of fat mass (-0.8 kgHMB vs. +0.8 kgPLA, p < 0.001). In turn, after HMB supplementation, in comparison to PLA, maximal oxygen uptake (V[Combining Dot Above][Combining Dot Above]O2max: +0.102 L·minHMB vs. -0.063 L·minPLA, p = 0.013), time to reach ventilatory threshold (VT) (TVT: +1.0 minHMB vs. -0.4 minPLA, p < 0.0001), threshold load at VT (WVT: +20 WHMB vs. -7 WPLA, p = 0.001), and the threshold heart rate at VT (HRVT: +8 b·minHMB vs. -1 b·minPLA, p < 0.0001) increased significantly. Analysis of the tested biochemical markers shows significant differences only in relation to the initial concentration. In HMB group, testosterone levels increased (p = 0.047) and in both groups (HMB: p = 0.008; PLA: p = 0.008) higher cortisol levels were observed. The results indicate that supplying HMB promotes advantageous changes in body composition and stimulates an increase in aerobic capacity, although seeming not to significantly affect the levels of the analyzed blood markers.
The Effects of Acute Exercise on Memory and Brain-Derived Neurotrophic Factor (BDNF).
Etnier, Jennifer L; Wideman, Laurie; Labban, Jeffrey D; Piepmeier, Aaron T; Pendleton, Daniel M; Dvorak, Kelly K; Becofsky, Katie
2016-08-01
Acute exercise benefits cognition, and some evidence suggests that brain-derived neurotrophic factor (BDNF) plays a role in this effect. The purpose of this study was to explore the dose-response relationship between exercise intensity, memory, and BDNF. Young adults completed 3 exercise sessions at different intensities relative to ventilator threshold (Vt) (VO 2max , Vt - 20%, Vt + 20%). For each session, participants exercised for approximately 30 min. Following exercise, they performed the Rey Auditory Verbal Learning Test (RAVLT) to assess short-term memory, learning, and long-term memory recall. Twenty-four hours later, they completed the RAVLT recognition trial, which provided another measure of long-term memory. Blood was drawn before exercise, immediately postexercise, and after the 30-min recall test. Results indicated that long-term memory as assessed after the 24-hr delay differed as a function of exercise intensity with the largest benefits observed following maximal intensity exercise. BDNF data showed a significant increase in response to exercise; however, there were no differences relative to exercise intensity and there were no significant associations between BDNF and memory. Future research is warranted so that we can better understand how to use exercise to benefit cognitive performance.
Effect of ferroelectric BaTiO3 particles on the threshold voltage of a smectic A liquid crystal
Imamaliyev, Abbas Rahim; Ramazanov, Mahammadali Ahmad
2018-01-01
The influence of small ferroelectric BaTiO3 particles on the planar–homeotropic transition threshold voltage in smectic A liquid crystals consisting of p-nitrophenyl p-decyloxybenzoate and 4-cyano-4′-pentylbiphenyl were studied by using capacitance–voltage (C–V) measurements. It was shown that the BaTiO3 particles significantly reduce the threshold voltage. The obtained result is explained by two factors: an increase of dielectric anisotropy of the liquid crystals and the formation of a strong electric field near polarized particles of BaTiO3. It was shown that the role of the second factor is dominant. The explanations of some features observed in the C–V characteristics are given. PMID:29600143
Electrical leakage detection circuit
Wild, Arthur
2006-09-05
A method is provided for detecting electrical leakage between a power supply and a frame of a vehicle or machine. The disclosed method includes coupling a first capacitor between a frame and a first terminal of a power supply for a predetermined period of time. The current flowing between the frame and the first capacitor is limited to a predetermined current limit. It is determined whether the voltage across the first capacitor exceeds a threshold voltage. A first output signal is provided when the voltage across the capacitor exceeds the threshold voltage.
Optimal Dynamic Sub-Threshold Technique for Extreme Low Power Consumption for VLSI
NASA Technical Reports Server (NTRS)
Duong, Tuan A.
2012-01-01
For miniaturization of electronics systems, power consumption plays a key role in the realm of constraints. Considering the very large scale integration (VLSI) design aspect, as transistor feature size is decreased to 50 nm and below, there is sizable increase in the number of transistors as more functional building blocks are embedded in the same chip. However, the consequent increase in power consumption (dynamic and leakage) will serve as a key constraint to inhibit the advantages of transistor feature size reduction. Power consumption can be reduced by minimizing the voltage supply (for dynamic power consumption) and/or increasing threshold voltage (V(sub th), for reducing leakage power). When the feature size of the transistor is reduced, supply voltage (V(sub dd)) and threshold voltage (V(sub th)) are also reduced accordingly; then, the leakage current becomes a bigger factor of the total power consumption. To maintain low power consumption, operation of electronics at sub-threshold levels can be a potentially strong contender; however, there are two obstacles to be faced: more leakage current per transistor will cause more leakage power consumption, and slow response time when the transistor is operated in weak inversion region. To enable low power consumption and yet obtain high performance, the CMOS (complementary metal oxide semiconductor) transistor as a basic element is viewed and controlled as a four-terminal device: source, drain, gate, and body, as differentiated from the traditional approach with three terminals: i.e., source and body, drain, and gate. This technique features multiple voltage sources to supply the dynamic control, and uses dynamic control to enable low-threshold voltage when the channel (N or P) is active, for speed response enhancement and high threshold voltage, and when the transistor channel (N or P) is inactive, to reduce the leakage current for low-leakage power consumption.
Choi, Bum-Rak; Li, Weiyan; Terentyev, Dmitry; Kabakov, Anatoli Y; Zhong, Mingwang; Rees, Colin M; Terentyeva, Radmila; Kim, Tae Yun; Qu, Zhilin; Peng, Xuwen; Karma, Alain; Koren, Gideon
2018-06-01
Sudden death in long-QT syndrome type 1 (LQT1), an inherited disease caused by loss-of-function mutations in KCNQ1, is triggered by early afterdepolarizations (EADs) that initiate polymorphic ventricular tachycardia (pVT). We investigated ionic mechanisms that underlie pVT in LQT1 using a transgenic rabbit model of LQT1. Optical mapping, cellular patch clamping, and computer modeling were used to elucidate the mechanisms of EADs in transgenic LQT1 rabbits. The results showed that shorter action potential duration in the right ventricle (RV) was associated with focal activity during pVT initiation. RV cardiomyocytes demonstrated higher incidence of EADs under 50 nmol/L isoproterenol. Voltage-clamp studies revealed that the transient outward potassium current (I to ) magnitude was 28% greater in RV associated with KChiP2 but with no differences in terms of calcium-cycling kinetics and other sarcolemmal currents. Perfusing with the I to blocker 4-aminopyridine changed the initial focal sites of pVT from the RV to the left ventricle, corroborating the role of I to in pVT initiation. Computer modeling showed that EADs occur preferentially in the RV because of the larger conductance of the slow-inactivating component of I to , which repolarizes the membrane potential sufficiently rapidly to allow reactivation of I Ca,L before I Kr has had sufficient time to activate. I to heterogeneity creates both triggers and an arrhythmogenic substrate in LQT1. In the absence of I Ks , I to interactions with I Ca,L and I Kr promote EADs in the RV while prolonging action potential duration in the left ventricle. This heterogeneity of action potential enhances dispersion of refractoriness and facilitates conduction blocks that initiate pVTs. © 2018 American Heart Association, Inc.
NASA Astrophysics Data System (ADS)
Tsao, Yu-Ching; Chang, Ting-Chang; Chen, Hua-Mao; Chen, Bo-Wei; Chiang, Hsiao-Cheng; Chen, Guan-Fu; Chien, Yu-Chieh; Tai, Ya-Hsiang; Hung, Yu-Ju; Huang, Shin-Ping; Yang, Chung-Yi; Chou, Wu-Ching
2017-01-01
This work demonstrates the generation of abnormal capacitance for amorphous indium-gallium-zinc oxide (a-InGaZnO4) thin-film transistors after being subjected to negative bias stress under ultraviolet light illumination stress (NBIS). At various operation frequencies, there are two-step tendencies in their capacitance-voltage curves. When gate bias is smaller than threshold voltage, the measured capacitance is dominated by interface defects. Conversely, the measured capacitance is dominated by oxygen vacancies when gate bias is larger than threshold voltage. The impact of these interface defects and oxygen vacancies on capacitance-voltage curves is verified by TCAD simulation software.
Evidence for thermally assisted threshold switching behavior in nanoscale phase-change memory cells
NASA Astrophysics Data System (ADS)
Le Gallo, Manuel; Athmanathan, Aravinthan; Krebs, Daniel; Sebastian, Abu
2016-01-01
In spite of decades of research, the details of electrical transport in phase-change materials are still debated. In particular, the so-called threshold switching phenomenon that allows the current density to increase steeply when a sufficiently high voltage is applied is still not well understood, even though there is wide consensus that threshold switching is solely of electronic origin. However, the high thermal efficiency and fast thermal dynamics associated with nanoscale phase-change memory (PCM) devices motivate us to reassess a thermally assisted threshold switching mechanism, at least in these devices. The time/temperature dependence of the threshold switching voltage and current in doped Ge2Sb2Te5 nanoscale PCM cells was measured over 6 decades in time at temperatures ranging from 40 °C to 160 °C. We observe a nearly constant threshold switching power across this wide range of operating conditions. We also measured the transient dynamics associated with threshold switching as a function of the applied voltage. By using a field- and temperature-dependent description of the electrical transport combined with a thermal feedback, quantitative agreement with experimental data of the threshold switching dynamics was obtained using realistic physical parameters.
Processing circuitry for single channel radiation detector
NASA Technical Reports Server (NTRS)
Holland, Samuel D. (Inventor); Delaune, Paul B. (Inventor); Turner, Kathryn M. (Inventor)
2009-01-01
Processing circuitry is provided for a high voltage operated radiation detector. An event detector utilizes a comparator configured to produce an event signal based on a leading edge threshold value. A preferred event detector does not produce another event signal until a trailing edge threshold value is satisfied. The event signal can be utilized for counting the number of particle hits and also for controlling data collection operation for a peak detect circuit and timer. The leading edge threshold value is programmable such that it can be reprogrammed by a remote computer. A digital high voltage control is preferably operable to monitor and adjust high voltage for the detector.
1983-10-01
will be: V(t) = 4,100 et/RC = 4,100 e 5/100 3,900 Volts Note that failure of a device during such test will classify the device as being Class 3 of DOD...Volts) 50 mV/small div., 50 nsec 0.1 mV/small div., 50 nsec (Inverted) NU-N E U Figure 12: (Charging Voltage: +1000 Volts) Figure 13: (Charging Voltage...Ij stchari I-,, i-1)401)0 1 It (uIrllis wi th vovy rt’~dIt- e l b (’i a, Ch .11it(! 11 1~ lit u t’ ~ 0 KV vult*.ge, I’Zinge anld at hw nFgrs 3~s. it
NASA Astrophysics Data System (ADS)
Kim, Jong Beom; Lee, Dong Ryeol
2018-04-01
We studied the effect of the addition of free hole- and electron-rich organic molecules to organic semiconductors (OSCs) in organic field effect transistors (OFETs) on the gate voltage-dependent mobility. The drain current versus gate voltage characteristics were quantitatively analyzed using an OFET mobility model of power law behavior based on hopping transport in an OSC. This analysis distinguished the threshold voltage shifts, depending on the materials and structures of the OFET device, and properly estimated the hopping transport of the charge carriers induced by the gate bias within the OSC from the power law exponent parameter. The addition of pentacene or C60 molecules to a one-monolayer pentacene-based OFET shifted the threshold voltages negatively or positively, respectively, due to the structural changes that occurred in the OFET device. On the other hand, the power law parameters revealed that the addition of charge carriers of the same or opposite polarity enhanced or hindered hopping transport, respectively. This study revealed the need for a quantitative analysis of the gate voltage-dependent mobility while distinguishing this effect from the threshold voltage effect in order to understand OSC hopping transport in OFETs.
NASA Astrophysics Data System (ADS)
Jiang, C.; Rumyantsev, S. L.; Samnakay, R.; Shur, M. S.; Balandin, A. A.
2015-02-01
We report on fabrication of MoS2 thin-film transistors (TFTs) and experimental investigations of their high-temperature current-voltage characteristics. The measurements show that MoS2 devices remain functional to temperatures of at least as high as 500 K. The temperature increase results in decreased threshold voltage and mobility. The comparison of the direct current (DC) and pulse measurements shows that the direct current sub-linear and super-linear output characteristics of MoS2 thin-films devices result from the Joule heating and the interplay of the threshold voltage and mobility temperature dependences. At temperatures above 450 K, a kink in the drain current occurs at zero gate voltage irrespective of the threshold voltage value. This intriguing phenomenon, referred to as a "memory step," was attributed to the slow relaxation processes in thin films similar to those in graphene and electron glasses. The fabricated MoS2 thin-film transistors demonstrated stable operation after two months of aging. The obtained results suggest new applications for MoS2 thin-film transistors in extreme-temperature electronics and sensors.
Second ventilatory threshold from heart-rate variability: valid when the upper body is involved?
Mourot, Laurent; Fabre, Nicolas; Savoldelli, Aldo; Schena, Federico
2014-07-01
To determine the most accurate method based on spectral analysis of heart-rate variability (SA-HRV) during an incremental and continuous maximal test involving the upper body, the authors tested 4 different methods to obtain the heart rate (HR) at the second ventilatory threshold (VT(2)). Sixteen ski mountaineers (mean ± SD; age 25 ± 3 y, height 177 ± 8 cm, mass 69 ± 10 kg) performed a roller-ski test on a treadmill. Respiratory variables and HR were continuously recorded, and the 4 SA-HRV methods were compared with the gas-exchange method through Bland and Altman analyses. The best method was the one based on a time-varying spectral analysis with high frequency ranging from 0.15 Hz to a cutoff point relative to the individual's respiratory sinus arrhythmia. The HR values were significantly correlated (r(2) = .903), with a mean HR difference with the respiratory method of 0.1 ± 3.0 beats/min and low limits of agreements (around -6 /+6 beats/min). The 3 other methods led to larger errors and lower agreements (up to 5 beats/min and around -23/+20 beats/min). It is possible to accurately determine VT(2) with an HR monitor during an incremental test involving the upper body if the appropriate HRV method is used.
A Dynamical Threshold for Cardiac Delayed Afterdepolarization-Mediated Triggered Activity.
Liu, Michael B; Ko, Christopher Y; Song, Zhen; Garfinkel, Alan; Weiss, James N; Qu, Zhilin
2016-12-06
Ventricular myocytes are excitable cells whose voltage threshold for action potential (AP) excitation is ∼-60 mV at which I Na is activated to give rise to a fast upstroke. Therefore, for a short stimulus pulse to elicit an AP, a stronger stimulus is needed if the resting potential lies further away from the I Na threshold, such as in hypokalemia. However, for an AP elicited by a long duration stimulus or a diastolic spontaneous calcium release, we observed that the stimulus needed was lower in hypokalemia than in normokalemia in both computer simulations and experiments of rabbit ventricular myocytes. This observation provides insight into why hypokalemia promotes calcium-mediated triggered activity, despite the resting potential lying further away from the I Na threshold. To understand the underlying mechanisms, we performed bifurcation analyses and demonstrated that there is a dynamical threshold, resulting from a saddle-node bifurcation mainly determined by I K1 and I NCX . This threshold is close to the voltage at which I K1 is maximum, and lower than the I Na threshold. After exceeding this dynamical threshold, the membrane voltage will automatically depolarize above the I Na threshold due to the large negative slope of the I K1 -V curve. This dynamical threshold becomes much lower in hypokalemia, especially with respect to calcium, as predicted by our theory. Because of the saddle-node bifurcation, the system can automatically depolarize even in the absence of I Na to voltages higher than the I Ca,L threshold, allowing for triggered APs in single myocytes with complete I Na block. However, because I Na is important for AP propagation in tissue, blocking I Na can still suppress premature ventricular excitations in cardiac tissue caused by calcium-mediated triggered activity. This suppression is more effective in normokalemia than in hypokalemia due to the difference in dynamical thresholds. Copyright © 2016 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Chien, China; Chang, Huiyi Harriet; Wu, Hsi-Yang
2015-08-01
Pediatric urinary incontinence has been proposed as a cause for adult urinary incontinence, yet animal models mimic the findings of overactive bladder more closely than dysfunctional voiding. We used the bladder reduction (BR) model to study the effects of early external urethral sphincter (EUS) dysfunction on the maturation of lower urinary tract function in neonatal and young adult rats of both sexes. To determine long-term alterations in bladder and EUS function in young adult rats caused by neonatal BR. 46 Sprague-Dawley rats underwent BR and 52 underwent sham surgery at 1 week of age. At 3, 6, and 9 weeks of life, cystometry was carried out, 8-OH-DPAT (serotonergic receptor agonist) and WAY 100,635 (serotonergic receptor antagonist) were administered intravenously. Pressure threshold (PT), volume threshold (VT), storage tonic AUC, contraction area under the curve (AUC), EUS burst amplitude and burst duration were measured at baseline and after administration of serotonergic agents. PT increased in 3-week BR females compared with shams (31.1 vs. 22.7 cm H2O, p < 0.01), in conjunction with less efficient EUS emptying, as burst amplitude was suppressed (BR 0.04 vs. sham 0.07 mV, p < 0.05). VT subsequently increased in 9-week BR females compared with shams (0.81 vs. 0.36 mL, p < 0.05). Although 3-week BR males also experienced suppressed burst amplitude (BR 0.17 vs. sham 0.28 mV, p < 0.05), they showed no difference in PT at 3 weeks or VT at 9 weeks compared with sham males. The burst amplitude returned to normal in 6- and 9-week BR animals of both sexes, confirming a spontaneous recovery of EUS function over time. The thresholds for voiding in male rats are not as sensitive to early changes in EUS function compared with female rats. The response to serotonergic agents was identical between BR and sham animals. In the female animals, 8-OH-DPAT increased storage tonic AUC and burst duration, whereas in male animals, 8-OH-DPAT increased contraction AUC, burst amplitude, and burst duration. WAY 100,635 reversed the enhancements of EUS function caused by 8-OH-DPAT. BR caused a temporary impairment of EUS emptying at 3 weeks of life, similar to dysfunctional voiding, while serotonergic agonists remained effective at enhancing EUS emptying in BR animals. Although EUS emptying spontaneously improved, the increase in VT in female young adult rats suggests that timely treatment of EUS dysfunction is required to decrease the risk of long-term bladder dysfunction. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Asenov, Asen; Kaya, S.; Davies, J. H.; Saini, S.
2000-01-01
We use the density gradient (DG) simulation approach to study, in 3D, the effect of local oxide thickness fluctuations on the threshold voltage of decanano MOSFETs in a statistical manner. A description of the reconstruction procedure for the random 2D surfaces representing the 'atomistic' Si-SiO2 interface variations is presented. The procedure is based on power spectrum synthesis in the Fourier domain and can include either Gaussian or exponential spectra. The simulations show that threshold voltage variations induced by oxide thickness fluctuation become significant when the gate length of the devices become comparable to the correlation length of the fluctuations. The extent of quantum corrections in the simulations with respect to the classical case and the dependence of threshold variations on the oxide thickness are examined.
Ma, R M; Peng, R M; Wen, X N; Dai, L; Liu, C; Sun, T; Xu, W J; Qin, G G
2010-10-01
We show that the threshold voltages of both n- and p-channel metal-oxide-semiconductor field-effect-transistors (MOSFETs) can be lowered to close to zero by adding extra Schottky contacts on top of nanowires (NWs). Novel complementary metal-oxide-semiconductor (CMOS) inverters are constructed on these Schottky barrier modified n- and p-channel NW MOSFETs. Based on the high performances of the modified n- and p-channel MOSFETs, especially the low threshold voltages, the as-fabricated CMOS inverters have low operating voltage, high voltage gain, and ultra-low static power dissipation.
NASA Astrophysics Data System (ADS)
Lükens, G.; Yacoub, H.; Kalisch, H.; Vescan, A.
2016-05-01
The interface charge density between the gate dielectric and an AlGaN/GaN heterostructure has a significant impact on the absolute value and stability of the threshold voltage Vth of metal-insulator-semiconductor (MIS) heterostructure field effect transistor. It is shown that a dry-etching step (as typically necessary for normally off devices engineered by gate-recessing) before the Al2O3 gate dielectric deposition introduces a high positive interface charge density. Its origin is most likely donor-type trap states shifting Vth to large negative values, which is detrimental for normally off devices. We investigate the influence of oxygen plasma annealing techniques of the dry-etched AlGaN/GaN surface by capacitance-voltage measurements and demonstrate that the positive interface charge density can be effectively compensated. Furthermore, only a low Vth hysteresis is observable making this approach suitable for threshold voltage engineering. Analysis of the electrostatics in the investigated MIS structures reveals that the maximum Vth shift to positive voltages achievable is fundamentally limited by the onset of accumulation of holes at the dielectric/barrier interface. In the case of the Al2O3/Al0.26Ga0.74N/GaN material system, this maximum threshold voltage shift is limited to 2.3 V.
Affect, exercise, and physical activity among healthy adolescents.
Schneider, Margaret; Dunn, Andrea; Cooper, Daniel
2009-12-01
Many adolescents do not meet public health recommendations for moderate-to-vigorous physical activity (MVPA). In studies of variables influencing adolescent MVPA, one that has been understudied is the affective response to exercise. We hypothesized that adolescents with a more positive affective response to acute exercise would be more active. Adolescents (N = 124; 46% male) completed two 30-min exercise tasks (above and below the ventilatory threshold [VT]), and wore ActiGraph accelerometers for 6.5 +/- 0.7 days. Affective valence was assessed before, during, and after each task. A more positive affective response during exercise below the VT was associated with greater participation in MVPA (p < .05). The results are consistent with the hypothesis that individuals who have a more positive affective response to exercise will engage in more MVPA. To promote greater participation in MVPA among adolescents, programs should be designed to facilitate a positive affective experience during exercise.
Direct electronic probing of biological complexes formation
NASA Astrophysics Data System (ADS)
Macchia, Eleonora; Magliulo, Maria; Manoli, Kyriaki; Giordano, Francesco; Palazzo, Gerardo; Torsi, Luisa
2014-10-01
Functional bio-interlayer organic field - effect transistors (FBI-OFET), embedding streptavidin, avidin and neutravidin as bio-recognition element, have been studied to probe the electronic properties of protein complexes. The threshold voltage control has been achieved modifying the SiO2 gate diaelectric surface by means of the deposition of an interlayer of bio-recognition elements. A threshold voltage shift with respect to the unmodified dielectric surface toward more negative potential values has been found for the three different proteins, in agreement with their isoelectric points. The relative responses in terms of source - drain current, mobility and threshold voltage upon exposure to biotin of the FBI-OFET devices have been compared for the three bio-recognition elements.
NASA Astrophysics Data System (ADS)
Na, Jun-Seok; Kwon, Oh-Kyong
2014-01-01
We propose pixel structures for large-size and high-resolution active matrix organic light-emitting diode (AMOLED) displays using a polycrystalline silicon (poly-Si) thin-film transistor (TFT) backplane. The proposed pixel structures compensate the variations of the threshold voltage and mobility of the driving TFT using the subthreshold current. The simulated results show that the emission current error of the proposed pixel structure B ranges from -2.25 to 2.02 least significant bit (LSB) when the variations of the threshold voltage and mobility of the driving TFT are ±0.5 V and ±10%, respectively.
Estimating the biophysical properties of neurons with intracellular calcium dynamics.
Ye, Jingxin; Rozdeba, Paul J; Morone, Uriel I; Daou, Arij; Abarbanel, Henry D I
2014-06-01
We investigate the dynamics of a conductance-based neuron model coupled to a model of intracellular calcium uptake and release by the endoplasmic reticulum. The intracellular calcium dynamics occur on a time scale that is orders of magnitude slower than voltage spiking behavior. Coupling these mechanisms sets the stage for the appearance of chaotic dynamics, which we observe within certain ranges of model parameter values. We then explore the question of whether one can, using observed voltage data alone, estimate the states and parameters of the voltage plus calcium (V+Ca) dynamics model. We find the answer is negative. Indeed, we show that voltage plus another observed quantity must be known to allow the estimation to be accurate. We show that observing both the voltage time course V(t) and the intracellular Ca time course will permit accurate estimation, and from the estimated model state, accurate prediction after observations are completed. This sets the stage for how one will be able to use a more detailed model of V+Ca dynamics in neuron activity in the analysis of experimental data on individual neurons as well as functional networks in which the nodes (neurons) have these biophysical properties.
Arrhythmogenic Risk Assessment Following Four-Week Pretreatment With Nicotine and Black Tea in Rat
Joukar, Siyavash; Sheibani, Vahid; Koushesh, Faramarz; Ghasemipoor Afshar, Elham; Ghorbani Shahrbabaki, Soodabe
2015-01-01
Background: There is the controversy concerning the main component of tobacco, which is responsible for its arrhythmogenesis. In addition, there is the lack of adequate information about the influence of combination of black tea and nicotine on heart rhythm. Objectives: This study aimed to examine whether pretreatment with black tea and nicotine could modulate the susceptibility to lethal ventricular arrhythmias. Materials and Methods: Animals were randomized to control, black tea, nicotine, and black tea plus nicotine groups. Test groups were treated with black tea brewed (orally) and nicotine (2 mg/kg, subcutaneous), alone and in combination for four weeks. On day 29, aconitine was infused intravenously for induction of cardiac arrhythmia. Results: In comparison with the control group, each of tea and nicotine significantly decreased the duration of the ventricular tachycardia (VT) plus ventricular fibrillation (VF) and the score of arrhythmia severity (P < 0.05 and P < 0.01, respectively,). The latency for the first VT event was significantly longer in the all test groups, but VF latency was significant only in tea and nicotine groups compared with control group (P < 0.05 and P < 0.01, respectively).Threshold dose of aconitine for inducing VT and VF increased in all test groups, but only VT showed a significant difference in comparison to the control group (P < 0.001). Conclusions: The findings suggest that sub-chronic consumption of nicotine or black tea alone with appropriate doses could potentially be antiarrhythmic and its combination regimen does not increase the risk of fatal ventricular arrhythmias during four-week consumption period in rats. PMID:26436072
Evidence for thermally assisted threshold switching behavior in nanoscale phase-change memory cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Le Gallo, Manuel; Athmanathan, Aravinthan; Krebs, Daniel
2016-01-14
In spite of decades of research, the details of electrical transport in phase-change materials are still debated. In particular, the so-called threshold switching phenomenon that allows the current density to increase steeply when a sufficiently high voltage is applied is still not well understood, even though there is wide consensus that threshold switching is solely of electronic origin. However, the high thermal efficiency and fast thermal dynamics associated with nanoscale phase-change memory (PCM) devices motivate us to reassess a thermally assisted threshold switching mechanism, at least in these devices. The time/temperature dependence of the threshold switching voltage and current inmore » doped Ge{sub 2}Sb{sub 2}Te{sub 5} nanoscale PCM cells was measured over 6 decades in time at temperatures ranging from 40 °C to 160 °C. We observe a nearly constant threshold switching power across this wide range of operating conditions. We also measured the transient dynamics associated with threshold switching as a function of the applied voltage. By using a field- and temperature-dependent description of the electrical transport combined with a thermal feedback, quantitative agreement with experimental data of the threshold switching dynamics was obtained using realistic physical parameters.« less
NASA Astrophysics Data System (ADS)
Ahn, Hyung-Woo; Seok Jeong, Doo; Cheong, Byung-ki; Lee, Hosuk; Lee, Hosun; Kim, Su-dong; Shin, Sang-Yeol; Kim, Donghwan; Lee, Suyoun
2013-07-01
We investigated the effect of nitrogen (N) doping on the threshold voltage of an ovonic threshold switching device using amorphous GeSe. Using the spectroscopic ellipsometry, we found that the addition of N brought about significant changes in electronic structure of GeSe, such as the density of localized states and the band gap energy. Besides, it was observed that the characteristics of OTS devices strongly depended on the doping of N, which could be attributed to those changes in electronic structure suggesting a method to modulate the threshold voltage of the device.
Low-threshold field emission in planar cathodes with nanocarbon materials
NASA Astrophysics Data System (ADS)
Zhigalov, V.; Petukhov, V.; Emelianov, A.; Timoshenkov, V.; Chaplygin, Yu.; Pavlov, A.; Shamanaev, A.
2016-12-01
Nanocarbon materials are of great interest as field emission cathodes due to their low threshold voltage. In this work current-voltage characteristics of nanocarbon electrodes were studied. Low-threshold emission was found in planar samples where field enhancement is negligible (<10). Electron work function values, calculated by Fowler-Nordheim theory, are anomalous low (<1 eV) and come into collision with directly measured work function values in fabricated planar samples (4.1-4.4 eV). Non-applicability of Fowler-Nordheim theory for the nanocarbon materials was confirmed. The reasons of low-threshold emission in nanocarbon materials are discussed.
SONOS Nonvolatile Memory Cell Programming Characteristics
NASA Technical Reports Server (NTRS)
MacLeod, Todd C.; Phillips, Thomas A.; Ho, Fat D.
2010-01-01
Silicon-oxide-nitride-oxide-silicon (SONOS) nonvolatile memory is gaining favor over conventional EEPROM FLASH memory technology. This paper characterizes the SONOS write operation using a nonquasi-static MOSFET model. This includes floating gate charge and voltage characteristics as well as tunneling current, voltage threshold and drain current characterization. The characterization of the SONOS memory cell predicted by the model closely agrees with experimental data obtained from actual SONOS memory cells. The tunnel current, drain current, threshold voltage and read drain current all closely agreed with empirical data.
Safety of American Heart Association-recommended minimum exercise for desmosomal mutation carriers.
Sawant, Abhishek C; Te Riele, Anneline S J M; Tichnell, Crystal; Murray, Brittney; Bhonsale, Aditya; Tandri, Harikrishna; Judge, Daniel P; Calkins, Hugh; James, Cynthia A
2016-01-01
Endurance exercise is associated with adverse outcomes in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C). Exercise recommendations for family members remain undetermined. The purposes of this study were to determine if (1) endurance exercise (Bethesda class C) and exercise intensity (metabolic equivalent hours per year [MET-Hr/year]) increase the likelihood of fulfilling 2010 Task Force Criteria and ventricular arrhythmias/implantable cardioverter-defibrillator shock (ventricular tachycardia/ventricular fibrillation [VT/VF]), and (2) exercise restriction to the American Heart Association (AHA)-recommended minimum for healthy adults is associated with favorable outcomes of at-risk family members. Twenty-eight family members of 10 probands inheriting a PKP2 mutation were interviewed about exercise from age 10. Exercise threshold to maintain overall health was based on the 2007 AHA guidelines of a minimum 390 to 650 MET-Hr/year. After adjustment for age, sex, and family membership, both participation in endurance athletics (odds ratio [OR] 7.4, P = .03) and higher-intensity exercise (OR = 4.2, P = .004) were associated with diagnosis (n = 13). Endurance athletes were also significantly more likely to develop VT/VF (n = 6, P = .02). Family members who restricted exercise at or below the upper bound of the AHA goal (≤650 MET-Hr/year) were significantly less likely to be diagnosed (OR = 0.07, P = .002) and had no VT/VF. At diagnosis and first VT/VF, family members had accumulated 2.8-fold (P = .002) and 3.5-fold (P = .03), respectively, greater MET-Hr exercise than the AHA-recommended minimum. Those who developed VT/VF had performed particularly high-intensity exercise in adolescence compared to unaffected family members (age 10-14: P = .04; age 14-19: P = .02). The results of this study suggest restricting unaffected desmosomal mutation carriers from endurance and high-intensity athletics but potentially not from AHA-recommended minimum levels of exercise for healthy adults. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Scaling properties of ballistic nano-transistors
2011-01-01
Recently, we have suggested a scale-invariant model for a nano-transistor. In agreement with experiments a close-to-linear thresh-old trace was found in the calculated ID - VD-traces separating the regimes of classically allowed transport and tunneling transport. In this conference contribution, the relevant physical quantities in our model and its range of applicability are discussed in more detail. Extending the temperature range of our studies it is shown that a close-to-linear thresh-old trace results at room temperatures as well. In qualitative agreement with the experiments the ID - VG-traces for small drain voltages show thermally activated transport below the threshold gate voltage. In contrast, at large drain voltages the gate-voltage dependence is weaker. As can be expected in our relatively simple model, the theoretical drain current is larger than the experimental one by a little less than a decade. PMID:21711899
Han, Su-Ting; Zhou, Ye; Yang, Qing Dan; Zhou, Li; Huang, Long-Biao; Yan, Yan; Lee, Chun-Sing; Roy, Vellaisamy A L
2014-02-25
Tunable memory characteristics are used in multioperational mode circuits where memory cells with various functionalities are needed in one combined device. It is always a challenge to obtain control over threshold voltage for multimode operation. On this regard, we use a strategy of shifting the work function of reduced graphene oxide (rGO) in a controlled manner through doping gold chloride (AuCl3) and obtained a gradient increase of rGO work function. By inserting doped rGO as floating gate, a controlled threshold voltage (Vth) shift has been achieved in both p- and n-type low voltage flexible memory devices with large memory window (up to 4 times for p-type and 8 times for n-type memory devices) in comparison with pristine rGO floating gate memory devices. By proper energy band engineering, we demonstrated a flexible floating gate memory device with larger memory window and controlled threshold voltage shifts.
NASA Astrophysics Data System (ADS)
Kim, Youngjun; Cho, Seongeun; Kim, Hyeran; Seo, Soonjoo; Lee, Hyun Uk; Lee, Jouhahn; Ko, Hyungduk; Chang, Mincheol; Park, Byoungnam
2017-09-01
Electric field-induced charge trapping and exciton dissociation were demonstrated at a penatcene/grapheme quantum dot (GQD) interface using a bottom contact bi-layer field effect transistor (FET) as an electrical nano-probe. Large threshold voltage shift in a pentacene/GQD FET in the dark arises from field-induced carrier trapping in the GQD layer or GQD-induced trap states at the pentacene/GQD interface. As the gate electric field increases, hysteresis characterized by the threshold voltage shift depending on the direction of the gate voltage scan becomes stronger due to carrier trapping associated with the presence of a GQD layer. Upon illumination, exciton dissociation and gate electric field-induced charge trapping simultaneously contribute to increase the threshold voltage window, which can potentially be exploited for photoelectric memory and/or photovoltaic devices through interface engineering.
Sun, Yi-Lin; Xie, Dan; Xu, Jian-Long; Zhang, Cheng; Dai, Rui-Xuan; Li, Xian; Meng, Xiang-Jian; Zhu, Hong-Wei
2016-01-01
Double-gated field effect transistors have been fabricated using the SWCNT networks as channel layer and the organic ferroelectric P(VDF-TrFE) film spin-coated as top gate insulators. Standard photolithography process has been adopted to achieve the patterning of organic P(VDF-TrFE) films and top-gate electrodes, which is compatible with conventional CMOS process technology. An effective way for modulating the threshold voltage in the channel of P(VDF-TrFE) top-gate transistors under polarization has been reported. The introduction of functional P(VDF-TrFE) gate dielectric also provides us an alternative method to suppress the initial hysteresis of SWCNT networks and obtain a controllable ferroelectric hysteresis behavior. Applied bottom gate voltage has been found to be another effective way to highly control the threshold voltage of the networked SWCNTs based FETs by electrostatic doping effect. PMID:26980284
A study on the temperature dependence of the threshold switching characteristics of Ge2Sb2Te5
NASA Astrophysics Data System (ADS)
Lee, Suyoun; Jeong, Doo Seok; Jeong, Jeung-hyun; Zhe, Wu; Park, Young-Wook; Ahn, Hyung-Woo; Cheong, Byung-ki
2010-01-01
We investigated the temperature dependence of the threshold switching characteristics of a memory-type chalcogenide material, Ge2Sb2Te5. We found that the threshold voltage (Vth) decreased linearly with temperature, implying the existence of a critical conductivity of Ge2Sb2Te5 for its threshold switching. In addition, we investigated the effect of bias voltage and temperature on the delay time (tdel) of the threshold switching of Ge2Sb2Te5 and described the measured relationship by an analytic expression which we derived based on a physical model where thermally activated hopping is a dominant transport mechanism in the material.
Hyodo, Kazuki; Dan, Ippeita; Kyutoku, Yasushi; Suwabe, Kazuya; Byun, Kyeongho; Ochi, Genta; Kato, Morimasa; Soya, Hideaki
2016-01-15
Previous studies have shown that higher aerobic fitness is related to higher cognitive function and higher task-related prefrontal activation in older adults. However, a holistic picture of these factors has yet to be presented. As a typical age-related change of brain activation, less lateralized activity in the prefrontal cortex during cognitive tasks has been observed in various neuroimaging studies. Thus, this study aimed to reveal the relationship between aerobic fitness, cognitive function, and frontal lateralization. Sixty male older adults each performed a submaximal incremental exercise test to determine their oxygen intake (V·O2) at ventilatory threshold (VT) in order to index their aerobic fitness. They performed a color-word Stroop task while prefrontal activation was monitored using functional near infrared spectroscopy. As an index of cognitive function, Stroop interference time was analyzed. Partial correlation analyses revealed significant correlations among higher VT, shorter Stroop interference time and greater left-lateralized dorsolateral prefrontal cortex (DLPFC) activation when adjusting for education. Moreover, mediation analyses showed that left-lateralized DLPFC activation significantly mediated the association between VT and Stroop interference time. These results suggest that higher aerobic fitness is associated with cognitive function via lateralized frontal activation in older adults. Copyright © 2015 Elsevier Inc. All rights reserved.
Robinson, Edward H; Stout, Jeffrey R; Miramonti, Amelia A; Fukuda, David H; Wang, Ran; Townsend, Jeremy R; Mangine, Gerald T; Fragala, Maren S; Hoffman, Jay R
2014-01-01
Previous research combining Calcium β-hydroxy-β-methylbutyrate (CaHMB) and running high-intensity interval training (HIIT) have shown positive effects on aerobic performance measures. The purpose of this study was to examine the effect of β-hydroxy-β-methylbutyric free acid (HMBFA) and cycle ergometry HIIT on maximal oxygen consumption (VO2peak), ventilatory threshold (VT), respiratory compensation point (RCP) and time to exhaustion (Tmax) in college-aged men and women. Thirty-four healthy men and women (Age: 22.7 ± 3.1 yrs ; VO2peak: 39.3 ± 5.0 ml · kg(-1) · min(-1)) volunteered to participate in this double-blind, placebo-controlled design study. All participants completed a series of tests prior to and following treatment. A peak oxygen consumption test was performed on a cycle ergometer to assess VO2peak, Tmax, VT, and RCP. Twenty-six participants were randomly assigned into either a placebo (PLA-HIIT) or 3 g per day of HMBFA (BetaTor™) (HMBFA-HIIT) group. Eight participants served as controls (CTL). Participants in the HIIT groups completed 12 HIIT (80-120% maximal workload) exercise sessions consisting of 5-6 bouts of a 2:1 minute cycling work to rest ratio protocol over a four-week period. Body composition was measured with dual energy x-ray absorptiometry (DEXA). Outcomes were assessed by ANCOVA with posttest means adjusted for pretest differences. The HMBFA-HIIT intervention showed significant (p < 0.05) gains in VO2peak, and VT, versus the CTL and PLA-HIIT group. Both PLA-HIIT and HMBFA-HIIT treatment groups demonstrated significant (p < 0.05) improvement over CTL for Tmax, and RCP with no significant difference between the treatment groups. There were no significant differences observed for any measures of body composition. An independent-samples t-test confirmed that there were no significant differences between the training volumes for the PLA-HIIT and HMBFA-HIIT groups. Our findings support the use of HIIT in combination with HMBFA to improve aerobic fitness in college age men and women. These data suggest that the addition of HMBFA supplementation may result in greater changes in VO2peak and VT than HIIT alone. The study was registered on ClinicalTrials.gov (ID NCT01941368).
High-wafer-yield, high-performance vertical cavity surface-emitting lasers
NASA Astrophysics Data System (ADS)
Li, Gabriel S.; Yuen, Wupen; Lim, Sui F.; Chang-Hasnain, Constance J.
1996-04-01
Vertical cavity surface emitting lasers (VCSELs) with very low threshold current and voltage of 340 (mu) A and 1.5 V is achieved. The molecular beam epitaxially grown wafers are grown with a highly accurate, low cost and versatile pre-growth calibration technique. One- hundred percent VCSEL wafer yield is obtained. Low threshold current is achieved with a native oxide confined structure with excellent current confinement. Single transverse mode with stable, predetermined polarization direction up to 18 times threshold is also achieved, due to stable index guiding provided by the structure. This is the highest value reported to data for VCSELs. We have established that p-contact annealing in these devices is crucial for low voltage operation, contrary to the general belief. Uniform doping in the mirrors also appears not to be inferior to complicated doping engineering. With these design rules, very low threshold voltage VCSELs are achieved with very simple growth and fabrication steps.
NASA Astrophysics Data System (ADS)
Pandey, Shivendra Kumar; Manivannan, Anbarasu
2017-07-01
Prefixing a weak electric field (incubation) might enhance the crystallization speed via pre-structural ordering and thereby achieving faster programming of phase change memory (PCM) devices. We employed a weak electric field, equivalent to a constant small voltage (that is incubation voltage, Vi of 0.3 V) to the applied voltage pulse, VA (main pulse) for a systematic understanding of voltage-dependent rapid threshold switching characteristics and crystallization (set) process of In3SbTe2 (IST) PCM devices. Our experimental results on incubation-assisted switching elucidate strikingly one order faster threshold switching, with an extremely small delay time, td of 300 ps, as compared with no incubation voltage (Vi = 0 V) for the same VA. Also, the voltage dependent characteristics of incubation-assisted switching dynamics confirm that the initiation of threshold switching occurs at a lower voltage of 0.82 times of VA. Furthermore, we demonstrate an incubation assisted ultrafast set process of IST device for a low VA of 1.7 V (˜18 % lesser compared to without incubation) within a short pulse-width of 1.5 ns (full width half maximum, FWHM). These findings of ultrafast switching, yet low power set process would immensely be helpful towards designing high speed PCM devices with low power operation.
Similarity between the response of memristive and memcapacitive circuits subjected to ramped voltage
NASA Astrophysics Data System (ADS)
Kanygin, Mikhail A.; Katkov, Mikhail V.; Pershin, Yuriy V.
2017-07-01
We report a similar feature in the response of resistor-memristor and capacitor-memcapacitor circuits with threshold-type memory devices driven by triangular waveform voltage. In both cases, the voltage across the memory device is stabilized during the switching of the memory device state. While in the memristive circuit this feature is observed when the applied voltage changes in one direction, the memcapacitive circuit with a ferroelectric memcapacitor demonstrates the voltage stabilization effect at both sweep directions. The discovered behavior of capacitor-memcapacitor circuit is also demonstrated experimentally. We anticipate that our observation can be used in the design of electronic circuits with emergent memory devices as well as in the identification and characterization of memory effects in threshold-type memory devices.
Liquid-Solid Dual-Gate Organic Transistors with Tunable Threshold Voltage for Cell Sensing.
Zhang, Yu; Li, Jun; Li, Rui; Sbircea, Dan-Tiberiu; Giovannitti, Alexander; Xu, Junling; Xu, Huihua; Zhou, Guodong; Bian, Liming; McCulloch, Iain; Zhao, Ni
2017-11-08
Liquid electrolyte-gated organic field effect transistors and organic electrochemical transistors have recently emerged as powerful technology platforms for sensing and simulation of living cells and organisms. For such applications, the transistors are operated at a gate voltage around or below 0.3 V because prolonged application of a higher voltage bias can lead to membrane rupturing and cell death. This constraint often prevents the operation of the transistors at their maximum transconductance or most sensitive regime. Here, we exploit a solid-liquid dual-gate organic transistor structure, where the threshold voltage of the liquid-gated conduction channel is controlled by an additional gate that is separated from the channel by a metal-oxide gate dielectric. With this design, the threshold voltage of the "sensing channel" can be linearly tuned in a voltage window exceeding 0.4 V. We have demonstrated that the dual-gate structure enables a much better sensor response to the detachment of human mesenchymal stem cells. In general, the capability of tuning the optimal sensing bias will not only improve the device performance but also broaden the material selection for cell-based organic bioelectronics.
Variable-Threshold Threshold Elements,
A threshold element is a mathematical model of certain types of logic gates and of a biological neuron. Much work has been done on the subject of... threshold elements with fixed thresholds; this study concerns itself with elements in which the threshold may be varied, variable- threshold threshold ...elements. Physical realizations include resistor-transistor elements, in which the threshold is simply a voltage. Variation of the threshold causes the
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feng, Liefeng, E-mail: fengliefeng@tju.edu.cn, E-mail: lihongru@nankai.edu.cn; Yang, Xiufang; Wang, Cunda
2015-04-15
The junction behavior of different narrow band-gap multi-quantum-well (MQW) laser diodes (LDs) confirmed that the jump in the junction voltage in the threshold region is a general characteristic of narrow band-gap LDs. The relative change in the 1310 nm LD is the most obvious. To analyze this sudden voltage change, the threshold region is divided into three stages by I{sub th}{sup l} and I{sub th}{sup u}, as shown in Fig. 2; I{sub th}{sup l} is the conventional threshold, and as long as the current is higher than this threshold, lasing exists and the IdV/dI-I plot drops suddenly; I{sub th}{sup u}more » is the steady lasing point, at which the separation of the quasi-Fermi levels of electron and holes across the active region (V{sub j}) is suddenly pinned. Based on the evolutionary model of dissipative structure theory, the rate equations of the photons in a single-mode LD were deduced in detail at I{sub th}{sup l} and I{sub th}{sup u}. The results proved that the observed behavior of stimulated emission suddenly substituting for spontaneous emission, in a manner similar to biological evolution, must lead to a sudden increase in the injection carriers in the threshold region, which then causes the sudden increase in the junction voltage in this region.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manivannan, Anbarasu, E-mail: anbarasu@iiti.ac.in, E-mail: ranjith@iith.ac.in; Sahu, Smriti; Myana, Santosh Kumar
2014-12-15
Minimizing the dimensions of the electrode could directly impact the energy-efficient threshold switching and programming characteristics of phase change memory devices. A ∼12–15 nm AFM probe-tip was employed as one of the electrodes for a systematic study of threshold switching of as-deposited amorphous GeTe{sub 6} thin films. This configuration enables low power threshold switching with an extremely low steady state current in the on state of 6–8 nA. Analysis of over 48 different probe locations on the sample reveals a stable Ovonic threshold switching behavior at threshold voltage, V{sub TH} of 2.4 ± 0.5 V and the off state was retained below a holding voltage,more » V{sub H} of 0.6 ± 0.1 V. All these probe locations exhibit repeatable on-off transitions for more than 175 pulses at each location. Furthermore, by utilizing longer biasing voltages while scanning, a plausible nano-scale control over the phase change behavior from as-deposited amorphous to crystalline phase was studied.« less
Relationship between left atrium catheter contact force and pacing threshold.
Barrio-López, Teresa; Ortiz, Mercedes; Castellanos, Eduardo; Lázaro, Carla; Salas, Jefferson; Madero, Sergio; Almendral, Jesús
2017-08-01
The purpose of this study is to analyze the relationship between contact force (CF) and pacing threshold in left atrium (LA). Six to ten LA sites were studied in 28 consecutive patients with atrial fibrillation undergoing pulmonary vein isolation. Median CF, bipolar and unipolar electrogram voltage, impedance, and bipolar and unipolar thresholds for consistent constant capture and for consistent intermittent capture were measured at each site. Pacing threshold measurements were performed at 188 LA sites. Both unipolar and bipolar pacing thresholds correlated significantly with median CF; however, unipolar pacing threshold correlated better (unipolar: Pearson R -0.45; p < 0.001; Spearman Rho -0.62; p < 0.001, bipolar: Pearson R -0.39; p < 0.001; Spearman Rho -0.52; p < 0.001). Consistent constant capture threshold had better correlation with median CF than consistent intermittent capture threshold for both unipolar and bipolar pacing (Pearson R -0.45; p < 0.001 and Spearman Rho -0.62; p < 0.001 vs. Pearson R -0.35; p < 0.001; Spearman Rho -0.52; p < 0.001). The best pacing threshold cutoff point to detect a good CF (>10 g) was 3.25 mA for unipolar pacing with 69% specificity and 73% sensitivity. Both increased to 80% specificity and 74% sensitivity for sites with normal bipolar voltage and a pacing threshold cutoff value of 2.85 mA. Pacing thresholds correlate with CF in human not previously ablated LA. Since the combination of a normal bipolar voltage and a unipolar pacing threshold <2.85 mA provide reasonable parameters of validity, pacing threshold could be of interest as a surrogate for CF in LA.
Marques-Neto, Silvio R; Maior, Alex S; Maranhão Neto, Geraldo A; Santos, Edil L
2012-07-01
Many studies have used the heart rate deflection points (HRDPs) during incremental exercise tests, because of their strong correlation with the anaerobic threshold. The aim of this study was to evaluate the profile of the HRDPs identified by a computerized method and compare them with ventilatory and lactate thresholds. Twenty-four professional soccer players (age, 22 ± 5 years; body mass, 74 ± 7 kg; height 177 ± 7 cm) volunteered for the study. The subjects completed a Bruce-protocol incremental treadmill exercise test to volitional fatigue. Heart rate (HR) and alveolar gas exchange were recorded continuously at ≥1 Hz during exercise testing. Subsequently, the time course of the HR was fit by a computer algorithm, and a set of lines yielding the lowest pooled residual sum of squares was chosen as the best fit. This procedure defined 2 HRDPs (HRDP1 and HRDP2). The HR break points averaged 43.9 ± 5.9 and 89.7 ± 7.5% of the VO2peak. The HRDP1 showed a poor correlation with ventilatory threshold (VT; r = 0.50), but HRDP2 was highly correlated to the respiratory compensation (RC) point (r = 0.98). Neither HRDP1 nor HRDP2 was correlated with LT1 (at VO2 = 2.26 ± 0.72 L·min(-1); r = 0.26) or LT2 (2.79 ± 0.59 L·min(-1); r = 0.49), respectively. LT1 and LT2 also were not well correlated with VT (2.93 ± 0.68 L·min(-1); r = 0.20) or RC (3.82 ± 0.60 L·min(-1); r = 0.58), respectively. Although the HR deflection points were not correlated to LT, HRDP2 could be identified in all the subjects and was strongly correlated with RC, consistent with a relationship to cardiorespiratory fatigue and endurance performance.
Effect of thermal insulation on the electrical characteristics of NbOx threshold switches
NASA Astrophysics Data System (ADS)
Wang, Ziwen; Kumar, Suhas; Wong, H.-S. Philip; Nishi, Yoshio
2018-02-01
Threshold switches based on niobium oxide (NbOx) are promising candidates as bidirectional selector devices in crossbar memory arrays and building blocks for neuromorphic computing. Here, it is experimentally demonstrated that the electrical characteristics of NbOx threshold switches can be tuned by engineering the thermal insulation. Increasing the thermal insulation by ˜10× is shown to produce ˜7× reduction in threshold current and ˜45% reduction in threshold voltage. The reduced threshold voltage leads to ˜5× reduction in half-selection leakage, which highlights the effectiveness of reducing half-selection leakage of NbOx selectors by engineering the thermal insulation. A thermal feedback model based on Poole-Frenkel conduction in NbOx can explain the experimental results very well, which also serves as a piece of strong evidence supporting the validity of the Poole-Frenkel based mechanism in NbOx threshold switches.
NASA Astrophysics Data System (ADS)
Ashenafi, Emeshaw
Integrated circuits (ICs) are moving towards system-on-a-chip (SOC) designs. SOC allows various small and large electronic systems to be implemented in a single chip. This approach enables the miniaturization of design blocks that leads to high density transistor integration, faster response time, and lower fabrication costs. To reap the benefits of SOC and uphold the miniaturization of transistors, innovative power delivery and power dissipation management schemes are paramount. This dissertation focuses on on-chip integration of power delivery systems and managing power dissipation to increase the lifetime of energy storage elements. We explore this problem from two different angels: On-chip voltage regulators and power gating techniques. On-chip voltage regulators reduce parasitic effects, and allow faster and efficient power delivery for microprocessors. Power gating techniques, on the other hand, reduce the power loss incurred by circuit blocks during standby mode. Power dissipation (Ptotal = Pstatic and Pdynamic) in a complementary metal-oxide semiconductor (CMOS) circuit comes from two sources: static and dynamic. A quadratic dependency on the dynamic switching power and a more than linear dependency on static power as a form of gate leakage (subthreshold current) exist. To reduce dynamic power loss, the supply power should be reduced. A significant reduction in power dissipation occurs when portions of a microprocessor operate at a lower voltage level. This reduction in supply voltage is achieved via voltage regulators or converters. Voltage regulators are used to provide a stable power supply to the microprocessor. The conventional off-chip switching voltage regulator contains a passive floating inductor, which is difficult to be implemented inside the chip due to excessive power dissipation and parasitic effects. Additionally, the inductor takes a very large chip area while hampering the scaling process. These limitations make passive inductor based on-chip regulator design very unattractive for SOC integration and multi-/many-core environments. To circumvent the challenges, three alternative techniques based on active circuit elements to replace the passive LC filter of the buck convertor are developed. The first inductorless on-chip switching voltage regulator architecture is based on a cascaded 2nd order multiple feedback (MFB) low-pass filter (LPF). This design has the ability to modulate to multiple voltage settings via pulse-with modulation (PWM). The second approach is a supplementary design utilizing a hybrid low drop-out scheme to lower the output ripple of the switching regulator over a wider frequency range. The third design approach allows the integration of an entire power management system within a single chipset by combining a highly efficient switching regulator with an intermittently efficient linear regulator (area efficient), for robust and highly efficient on-chip regulation. The static power (Pstatic) or subthreshold leakage power (Pleak) increases with technology scaling. To mitigate static power dissipation, power gating techniques are implemented. Power gating is one of the popular methods to manage leakage power during standby periods in low-power high-speed IC design. It works by using transistor based switches to shut down part of the circuit block and put them in the idle mode. The efficiency of a power gating scheme involves minimum Ioff and high Ion for the sleep transistor. A conventional sleep transistor circuit design requires an additional header, footer, or both switches to turn off the logic block. This additional transistor causes signal delay and increases the chip area. We propose two innovative designs for next generation sleep transistor designs. For an above threshold operation, we present a sleep transistor design based on fully depleted silicon-on-insulator (FDSOI) device. For a subthreshold circuit operation, we implement a sleep transistor utilizing the newly developed silicon-on-ferroelectric-insulator field effect transistor (SOFFET). In both of the designs, the ability to control the threshold voltage via bias voltage at the back gate makes both devices more flexible for sleep transistors design than a bulk MOSFET. The proposed approaches simplify the design complexity, reduce the chip area, eliminate the voltage drop by sleep transistor, and improve power dissipation. In addition, the design provides a dynamically controlled Vt for times when the circuit needs to be in a sleep or switching mode.
NASA Astrophysics Data System (ADS)
Tang, Lan-Feng; Yu, Guang; Lu, Hai; Wu, Chen-Fei; Qian, Hui-Min; Zhou, Dong; Zhang, Rong; Zheng, You-Dou; Huang, Xiao-Ming
2015-08-01
The influence of white light illumination on the stability of an amorphous InGaZnO thin film transistor is investigated in this work. Under prolonged positive gate bias stress, the device illuminated by white light exhibits smaller positive threshold voltage shift than the device stressed under dark. There are simultaneous degradations of field-effect mobility for both stressed devices, which follows a similar trend to that of the threshold voltage shift. The reduced threshold voltage shift under illumination is explained by a competition between bias-induced interface carrier trapping effect and photon-induced carrier detrapping effect. It is further found that white light illumination could even excite and release trapped carriers originally exiting at the device interface before positive gate bias stress, so that the threshold voltage could recover to an even lower value than that in an equilibrium state. The effect of photo-excitation of oxygen vacancies within the a-IGZO film is also discussed. Project supported by the State Key Program for Basic Research of China (Grant Nos. 2011CB301900 and 2011CB922100) and the Priority Academic Program Development of Jiangsu Higher Education Institutions, China.
NASA Astrophysics Data System (ADS)
Lisauskas, Alvydas; Ikamas, Kestutis; Massabeau, Sylvain; Bauer, Maris; ČibiraitÄ--, DovilÄ--; Matukas, Jonas; Mangeney, Juliette; Mittendorff, Martin; Winnerl, Stephan; Krozer, Viktor; Roskos, Hartmut G.
2018-05-01
We propose to exploit rectification in field-effect transistors as an electrically controllable higher-order nonlinear phenomenon for the convenient monitoring of the temporal characteristics of THz pulses, for example, by autocorrelation measurements. This option arises because of the existence of a gate-bias-controlled super-linear response at sub-threshold operation conditions when the devices are subjected to THz radiation. We present measurements for different antenna-coupled transistor-based THz detectors (TeraFETs) employing (i) AlGaN/GaN high-electron-mobility and (ii) silicon CMOS field-effect transistors and show that the super-linear behavior in the sub-threshold bias regime is a universal phenomenon to be expected if the amplitude of the high-frequency voltage oscillations exceeds the thermal voltage. The effect is also employed as a tool for the direct determination of the speed of the intrinsic TeraFET response which allows us to avoid limitations set by the read-out circuitry. In particular, we show that the build-up time of the intrinsic rectification signal of a patch-antenna-coupled CMOS detector changes from 20 ps in the deep sub-threshold voltage regime to below 12 ps in the vicinity of the threshold voltage.
Threshold-voltage modulated phase change heterojunction for application of high density memory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yan, Baihan; Tong, Hao, E-mail: tonghao@hust.edu.cn; Qian, Hang
2015-09-28
Phase change random access memory is one of the most important candidates for the next generation non-volatile memory technology. However, the ability to reduce its memory size is compromised by the fundamental limitations inherent in the CMOS technology. While 0T1R configuration without any additional access transistor shows great advantages in improving the storage density, the leakage current and small operation window limit its application in large-scale arrays. In this work, phase change heterojunction based on GeTe and n-Si is fabricated to address those problems. The relationship between threshold voltage and doping concentration is investigated, and energy band diagrams and X-raymore » photoelectron spectroscopy measurements are provided to explain the results. The threshold voltage is modulated to provide a large operational window based on this relationship. The switching performance of the heterojunction is also tested, showing a good reverse characteristic, which could effectively decrease the leakage current. Furthermore, a reliable read-write-erase function is achieved during the tests. Phase change heterojunction is proposed for high-density memory, showing some notable advantages, such as modulated threshold voltage, large operational window, and low leakage current.« less
NASA Astrophysics Data System (ADS)
Oby, Emily R.; Perel, Sagi; Sadtler, Patrick T.; Ruff, Douglas A.; Mischel, Jessica L.; Montez, David F.; Cohen, Marlene R.; Batista, Aaron P.; Chase, Steven M.
2016-06-01
Objective. A traditional goal of neural recording with extracellular electrodes is to isolate action potential waveforms of an individual neuron. Recently, in brain-computer interfaces (BCIs), it has been recognized that threshold crossing events of the voltage waveform also convey rich information. To date, the threshold for detecting threshold crossings has been selected to preserve single-neuron isolation. However, the optimal threshold for single-neuron identification is not necessarily the optimal threshold for information extraction. Here we introduce a procedure to determine the best threshold for extracting information from extracellular recordings. We apply this procedure in two distinct contexts: the encoding of kinematic parameters from neural activity in primary motor cortex (M1), and visual stimulus parameters from neural activity in primary visual cortex (V1). Approach. We record extracellularly from multi-electrode arrays implanted in M1 or V1 in monkeys. Then, we systematically sweep the voltage detection threshold and quantify the information conveyed by the corresponding threshold crossings. Main Results. The optimal threshold depends on the desired information. In M1, velocity is optimally encoded at higher thresholds than speed; in both cases the optimal thresholds are lower than are typically used in BCI applications. In V1, information about the orientation of a visual stimulus is optimally encoded at higher thresholds than is visual contrast. A conceptual model explains these results as a consequence of cortical topography. Significance. How neural signals are processed impacts the information that can be extracted from them. Both the type and quality of information contained in threshold crossings depend on the threshold setting. There is more information available in these signals than is typically extracted. Adjusting the detection threshold to the parameter of interest in a BCI context should improve our ability to decode motor intent, and thus enhance BCI control. Further, by sweeping the detection threshold, one can gain insights into the topographic organization of the nearby neural tissue.
Oby, Emily R; Perel, Sagi; Sadtler, Patrick T; Ruff, Douglas A; Mischel, Jessica L; Montez, David F; Cohen, Marlene R; Batista, Aaron P; Chase, Steven M
2018-01-01
Objective A traditional goal of neural recording with extracellular electrodes is to isolate action potential waveforms of an individual neuron. Recently, in brain–computer interfaces (BCIs), it has been recognized that threshold crossing events of the voltage waveform also convey rich information. To date, the threshold for detecting threshold crossings has been selected to preserve single-neuron isolation. However, the optimal threshold for single-neuron identification is not necessarily the optimal threshold for information extraction. Here we introduce a procedure to determine the best threshold for extracting information from extracellular recordings. We apply this procedure in two distinct contexts: the encoding of kinematic parameters from neural activity in primary motor cortex (M1), and visual stimulus parameters from neural activity in primary visual cortex (V1). Approach We record extracellularly from multi-electrode arrays implanted in M1 or V1 in monkeys. Then, we systematically sweep the voltage detection threshold and quantify the information conveyed by the corresponding threshold crossings. Main Results The optimal threshold depends on the desired information. In M1, velocity is optimally encoded at higher thresholds than speed; in both cases the optimal thresholds are lower than are typically used in BCI applications. In V1, information about the orientation of a visual stimulus is optimally encoded at higher thresholds than is visual contrast. A conceptual model explains these results as a consequence of cortical topography. Significance How neural signals are processed impacts the information that can be extracted from them. Both the type and quality of information contained in threshold crossings depend on the threshold setting. There is more information available in these signals than is typically extracted. Adjusting the detection threshold to the parameter of interest in a BCI context should improve our ability to decode motor intent, and thus enhance BCI control. Further, by sweeping the detection threshold, one can gain insights into the topographic organization of the nearby neural tissue. PMID:27097901
Oby, Emily R; Perel, Sagi; Sadtler, Patrick T; Ruff, Douglas A; Mischel, Jessica L; Montez, David F; Cohen, Marlene R; Batista, Aaron P; Chase, Steven M
2016-06-01
A traditional goal of neural recording with extracellular electrodes is to isolate action potential waveforms of an individual neuron. Recently, in brain-computer interfaces (BCIs), it has been recognized that threshold crossing events of the voltage waveform also convey rich information. To date, the threshold for detecting threshold crossings has been selected to preserve single-neuron isolation. However, the optimal threshold for single-neuron identification is not necessarily the optimal threshold for information extraction. Here we introduce a procedure to determine the best threshold for extracting information from extracellular recordings. We apply this procedure in two distinct contexts: the encoding of kinematic parameters from neural activity in primary motor cortex (M1), and visual stimulus parameters from neural activity in primary visual cortex (V1). We record extracellularly from multi-electrode arrays implanted in M1 or V1 in monkeys. Then, we systematically sweep the voltage detection threshold and quantify the information conveyed by the corresponding threshold crossings. The optimal threshold depends on the desired information. In M1, velocity is optimally encoded at higher thresholds than speed; in both cases the optimal thresholds are lower than are typically used in BCI applications. In V1, information about the orientation of a visual stimulus is optimally encoded at higher thresholds than is visual contrast. A conceptual model explains these results as a consequence of cortical topography. How neural signals are processed impacts the information that can be extracted from them. Both the type and quality of information contained in threshold crossings depend on the threshold setting. There is more information available in these signals than is typically extracted. Adjusting the detection threshold to the parameter of interest in a BCI context should improve our ability to decode motor intent, and thus enhance BCI control. Further, by sweeping the detection threshold, one can gain insights into the topographic organization of the nearby neural tissue.
Van, Ngoc Huynh; Lee, Jae-Hyun; Sohn, Jung Inn; Cha, Seung Nam; Whang, Dongmok; Kim, Jong Min; Kang, Dae Joon
2014-05-21
We successfully fabricated nanowire-based complementary metal-oxide semiconductor (NWCMOS) inverter devices by utilizing n- and p-type Si nanowire field-effect-transistors (NWFETs) via a low-temperature fabrication processing technique. We demonstrate that NWCMOS inverter devices can be operated at less than 1 V, a significantly lower voltage than that of typical thin-film based complementary metal-oxide semiconductor (CMOS) inverter devices. This low-voltage operation was accomplished by controlling the threshold voltage of the n-type Si NWFETs through effective management of the nanowire (NW) doping concentration, while realizing high voltage gain (>10) and ultra-low static power dissipation (≤3 pW) for high-performance digital inverter devices. This result offers a viable means of fabricating high-performance, low-operation voltage, and high-density digital logic circuits using a low-temperature fabrication processing technique suitable for next-generation flexible electronics.
Modeling of Gate Bias Modulation in Carbon Nanotube Field-Effect-Transistor
NASA Technical Reports Server (NTRS)
Toshishige, Yamada; Biegel, Bryan A. (Technical Monitor)
2002-01-01
The threshold voltages of a carbon-nanotube (CNT) field-effect transistor (FET) are studied. The CNT channel is so thin that there is no voltage drop perpendicular to the gate electrode plane, and this makes the device characteristics quite unique. The relation between the voltage and the electrochemical potentials, and the mass action law for electrons and holes are examined in the context of CNTs, and inversion and accumulation threshold voltages (V(sub Ti), and V(sub Ta)) are derived. V(sub Ti) of the CNTFETs has a much stronger doping dependence than that of the metal-oxide- semiconductor FETs, while V(sub Ta) of both devices depends weakly on doping with the same functional form.
Zhu, Ye; Gu, Xiang; Xu, Chao
2017-10-16
Implantable cardioverter defibrillators (ICD) are capable of effectively terminating malignant ventricular arrhythmia and are the most effective way to prevent sudden cardiac death. However, some evidences demonstrated that both anti-tachycardia pacing (ATP) and ICD shock can also bring adverse prognosis. A 66-year-old Han Chinese man with prior ICD implantation was admitted to our hospital because of frequent ICD shocks. Although intravenous amiodarone and esmolol succinate were administered daily, the patient suffered 155 episodes of VT/VF during 8 weeks after implantation. After repeated discharge of the device, the pacing threshold of the patient increased gradually. Considering the inappropriate increase of the pacing threshold, we decided to reposition the right ventricular (RV) lead with good sensing and threshold parameters confirmed. Subsequent 22 months interrogation follow-up revealed a stable lead position and electrical specifications. Furthermore, antiarrhythmic drugs were maximally increased, while ATP burst was remarkably decreased and the inappropriate ICD shock never occurred until now. An inappropriate pacing threshold was increased secondary to repeated ICD electrical storm. A timely active lead position adjustment reduced the pacing threshold and eliminated the risk of premature battery depletion.
Muir, Ryan D.; Pogranichney, Nicholas R.; Muir, J. Lewis; Sullivan, Shane Z.; Battaile, Kevin P.; Mulichak, Anne M.; Toth, Scott J.; Keefe, Lisa J.; Simpson, Garth J.
2014-01-01
Experiments and modeling are described to perform spectral fitting of multi-threshold counting measurements on a pixel-array detector. An analytical model was developed for describing the probability density function of detected voltage in X-ray photon-counting arrays, utilizing fractional photon counting to account for edge/corner effects from voltage plumes that spread across multiple pixels. Each pixel was mathematically calibrated by fitting the detected voltage distributions to the model at both 13.5 keV and 15.0 keV X-ray energies. The model and established pixel responses were then exploited to statistically recover images of X-ray intensity as a function of X-ray energy in a simulated multi-wavelength and multi-counting threshold experiment. PMID:25178010
Muir, Ryan D; Pogranichney, Nicholas R; Muir, J Lewis; Sullivan, Shane Z; Battaile, Kevin P; Mulichak, Anne M; Toth, Scott J; Keefe, Lisa J; Simpson, Garth J
2014-09-01
Experiments and modeling are described to perform spectral fitting of multi-threshold counting measurements on a pixel-array detector. An analytical model was developed for describing the probability density function of detected voltage in X-ray photon-counting arrays, utilizing fractional photon counting to account for edge/corner effects from voltage plumes that spread across multiple pixels. Each pixel was mathematically calibrated by fitting the detected voltage distributions to the model at both 13.5 keV and 15.0 keV X-ray energies. The model and established pixel responses were then exploited to statistically recover images of X-ray intensity as a function of X-ray energy in a simulated multi-wavelength and multi-counting threshold experiment.
NASA Technical Reports Server (NTRS)
Asenov, Asen; Slavcheva, G.; Brown, A. R.; Davies, J. H.; Saini, Subhash
1999-01-01
A detailed study of the influence of quantum effects in the inversion layer on the random dopant induced threshold voltage fluctuations and lowering in sub 0.1 micron MOSFETs has been performed. This has been achieved using a full 3D implementation of the density gradient (DG) formalism incorporated in our previously published 3D 'atomistic' simulation approach. This results in a consistent, fully 3D, quantum mechanical picture which implies not only the vertical inversion layer quantisation but also the lateral confinement effects manifested by current filamentation in the 'valleys' of the random potential fluctuations. We have shown that the net result of including quantum mechanical effects, while considering statistical fluctuations, is an increase in both threshold voltage fluctuations and lowering.
Reactive power and voltage control strategy based on dynamic and adaptive segment for DG inverter
NASA Astrophysics Data System (ADS)
Zhai, Jianwei; Lin, Xiaoming; Zhang, Yongjun
2018-03-01
The inverter of distributed generation (DG) can support reactive power to help solve the problem of out-of-limit voltage in active distribution network (ADN). Therefore, a reactive voltage control strategy based on dynamic and adaptive segment for DG inverter is put forward to actively control voltage in this paper. The proposed strategy adjusts the segmented voltage threshold of Q(U) droop curve dynamically and adaptively according to the voltage of grid-connected point and the power direction of adjacent downstream line. And then the reactive power reference of DG inverter can be got through modified Q(U) control strategy. The reactive power of inverter is controlled to trace the reference value. The proposed control strategy can not only control the local voltage of grid-connected point but also help to maintain voltage within qualified range considering the terminal voltage of distribution feeder and the reactive support for adjacent downstream DG. The scheme using the proposed strategy is compared with the scheme without the reactive support of DG inverter and the scheme using the Q(U) control strategy with constant segmented voltage threshold. The simulation results suggest that the proposed method has a significant improvement on solving the problem of out-of-limit voltage, restraining voltage variation and improving voltage quality.
Vogel, T; Leprêtre, P-M; Brechat, P-H; Lonsdorfer, E; Benetos, A; Kaltenbach, G; Lonsdorfer, J
2011-12-01
The aim of this study was to evaluate the efficiency of a short-term Intermittent Work Exercise Program (IWEP) among healthy elderly subjects. This longitudinal prospective study took place at the Strasbourg University Hospital geriatric department. One hundred and fifty older volunteers, previously determined as being free from cardiac and pulmonary disease, were separated into two age groups: the "young senior" (60.2 ± 3.1 yr) and the "older senior" groups (70.8 ± 5.2 yr). These groups were then subdivided by gender into the "young female senior", "young male senior" "older female senior" and "older male senior" groups. Before and after the IWEP, all subjects were asked to perform an incremental cycle exercise to obtain their first ventilatory threshold (VT1), maximal tolerated power (MTP), peak oxygen uptake (VO2peak) and maximal minute ventilation (MMV). The IWEP consisted of a 30-min cycling exercise which took place twice a week, and was divided into six 5-min stages consisting of 4 min at VT1 intensity and 1 min at 90% MTP. An assessment was made of the effects of the IWEP on maximal cardio-respiratory function (MTP, VO2peak, MMV) and endurance parameters (VT1, heart rate [HR] measured at pretraining VT1 and lactate concentrations at pre-training MTP). This short-term training program resulted in a significant increase of MTP (from 13.2% to 20.6%), VO2peak (from 8.9% to 16.6%) and MMV (from 11.1% to 21.8%) in all groups (p<0.05). VT1 improved from 21% at pretraining to 27%, while HR at pre-training VT1 as well as lactate concentrations at pre-training MTP decreased significantly in all groups (p<0.05). The post-training values for VO2peak and MMV of the "older seniors" were not significantly different (p>0.05) from the "young seniors" pre-training values for the same parameters. The most striking finding in this study is that after only 9 weeks, our short-term "individually-tailored" IWEP significantly improved both maximal cardio-respiratory function and endurance parameters in healthy, previously untrained seniors.
Effects of Reduced Strength on Self-Selected Pacing for Long-Duration Activities
NASA Technical Reports Server (NTRS)
Buxton, Roxanne E.; Ryder, Jeffrey W.; English, Kirk E.; Guined, Jamie R.; Ploutz-Snyder, Lori L.
2015-01-01
Strength and aerobic capacity are predictors of astronaut performance for extravehicular activities (EVA) during exploration missions. It is expected that astronauts will self-select a pace below their ventilatory threshold (VT). PURPOSE: To determine the percentage of VT that subjects self-select for prolonged occupational tasks. METHODS: Maximal aerobic capacity and a variety of lower-body strength and power variables were assessed in 17 subjects who climbed 480 rungs on a ladder ergometer and then completed 10 km on a treadmill as quickly as possible using a self-selected pace. The tasks were performed on 4 days, with a weighted suit providing 0% (suit fabric only), 40%, 60%, and 80% of additional bodyweight (BW), thereby altering the strength to BW ratio. Oxygen consumption and heart rate were continuously measured. Repeated measures ANOVA and post-hoc comparisons were performed on the percent of VT values under each suited condition. RESULTS: Subjects consistently self-paced at or below VT for both tasks and the pace was related to suit weight. At the midpoint for the ladder climb the 80% BW condition elicited the lowest metabolic cost (-19+/-14% below VT), significantly different than the 0% BW (-3+/-16%, P=0.002) and the 40% BW conditions (-5+/-22%, P=0.023). The 60% BW condition (-13+/-19%) was different than the 40% BW condition (P=0.034). Upon completion of the ladder task there were no differences among the conditions (0%BW: 3+/-18%; 40%BW: 3+/-21%; 60%BW: - 8+/-25%; 80%BW: -10+/-18%). All subjects failed to complete 5km at 80%BW. At the midpoint of the treadmill test the three remaining conditions were all significantly different (0%BW: -20+/-15%; 40%BW: - 33+/-15%; 60%BW: -41+/-19%). Upon completion of the treadmill test the 60% BW condition (-38+/-12%) was significantly different than the 40% BW (-28+/-15%, P=0.024). CONCLUSIONS: Decreasing relative strength results in progressive and disproportionate decreases (relative to VT) in self-selected pacing during long-duration activities. Thus, during prolonged, endurance-type activities, large reductions in strength cause notable performance decrements despite no changes in aerobic capacity. These data highlight the importance of both aerobic capacity and muscle strength to the performance of prolonged EVA in exploration mission scenarios.
Modeling Radiation Effects on a Triple Junction Solar Cell using Silvaco ATLAS
2012-06-01
circuit voltage can then be calculated from ln 1 Loc t S IV V I (4.3) where IS is the reverse saturation current, and Vt is the...orbiting electronic equipment. The first orbit of interest is the low Earth orbit ( LEO ). LEO encompasses any orbit within 650 kilometers of the...Light Beams #Solving #Meshing mesh width=200000 #X-Mesh: Surface=500 um2 = 1/200000 cm2 x.mesh loc =-250 spac=50 x.mesh loc =0 spac=10
Noise characterization of enhancement-mode AlGaN graded barrier MIS-HEMT devices
NASA Astrophysics Data System (ADS)
Mohanbabu, A.; Saravana Kumar, R.; Mohankumar, N.
2017-12-01
This paper reports a systematic theoretical study on the microwave noise performance of graded AlGaN/GaN metal-insulator semiconductor high-electron mobility transistors (MIS-HEMTs) built on an Al2O3 substrate. The HfAlOx/AlGaN/GaN MIS-HEMT devices designed for this study show an outstanding small signal analog/RF and noise performance. The results on 1 μm gate length device show an enhancement mode operation with threshold voltage, VT = + 5.3 V, low drain leakage current, Ids,LL in the order of 1 × 10-9 A/mm along with high current gain cut-off frequency, fT of 17 GHz and maximum oscillation frequency fmax of 47 GHz at Vds = 10 V. The device Isbnd V and low-frequency noise estimation of the gate and drain noise spectral density and their correlation are evaluated using a Green's function method under different biasing conditions. The devices show a minimum noise figure (NFmin) of 1.053 dB in combination with equivalent noise resistance (Rn) of 23 Ω at 17 GHz, at Vgs = 6 V and Vds = 5 V which is relatively low and is suitable for broad-band low-noise amplifiers. This study shows that the graded AlGaN MIS-HEMT with HfAlOX gate insulator is appropriate for application requiring high-power and low-noise.
NASA Astrophysics Data System (ADS)
Mohanbabu, A.; Mohankumar, N.; Godwin Raj, D.; Sarkar, Partha
2017-08-01
In this paper, we examined normally-OFF N-polar InN-channel Metal insulated semiconductor high-electron mobility transistors (MISHEMTs) device with a relaxed In0.9Al0.1N buffer layer. In addition, the enhancement-mode operation of the N-polar structure was investigated. The effect of scaling in N-polar MISHEMT, such as the dielectric and the channel thickness, alter the electrical behavior of the device. We have achieved a maximum drain current of 1.17 A/mm, threshold voltage (VT) =0.728 V, transconductance (gm) of 2.9 S mm-1, high ION/IOFF current ratio of 3.23×103, lowest ON-state resistance (RON) of 0.41 Ω mm and an intrinsic delay time (τ) of 1.456 Fs along with high-frequency performance with ft/ fmaxof 90 GHz/109 GHz and 180 GHz/260 GHz for TCH =0.5 nm at Vds =0.5 V and 1.0 V. The numerically simulated results of highly confined GaN/InN/GaN/In0.9Al0.1N heterostructure MISHEMT exhibits outstanding potential as one of the possibility to replace presently used N-polar MISHEMTs for delivering high power density and frequency at RF/power amplifier applications.
Vivodtzev, Isabelle; Gagnon, Philippe; Pepin, Véronique; Saey, Didier; Laviolette, Louis; Brouillard, Cynthia; Maltais, François
2011-01-01
Rationale The endurance time (Tend) during constant-workrate cycling exercise (CET) is highly variable in COPD. We investigated pulmonary and physiological variables that may contribute to these variations in Tend. Methods Ninety-two patients with COPD completed a CET performed at 80% of peak workrate capacity (Wpeak). Patients were divided into tertiles of Tend [Group 1: <4 min; Group 2: 4–6 min; Group 3: >6 min]. Disease severity (FEV1), aerobic fitness (Wpeak, peak oxygen consumption [ peak], ventilatory threshold [ VT]), quadriceps strength (MVC), symptom scores at the end of CET and exercise intensity during CET (heart rate at the end of CET to heart rate at peak incremental exercise ratio [HRCET/HRpeak]) were analyzed as potential variables influencing Tend. Results Wpeak, peak, VT, MVC, leg fatigue at end of CET, and HRCET/HRpeak were lower in group 1 than in group 2 or 3 (p≤0.05). VT and leg fatigue at end of CET independently predicted Tend in multiple regression analysis (r = 0.50, p = 0.001). Conclusion Tend was independently related to the aerobic fitness and to tolerance to leg fatigue at the end of exercise. A large fraction of the variability in Tend was not explained by the physiological parameters assessed in the present study. Individualization of exercise intensity during CET should help in reducing variations in Tend among patients with COPD. PMID:21386991
Evans, B W; Potteiger, J A
1995-06-01
This study compared ventilatory and metabolic responses during exercise using three breathing assemblies: mouthpiece/noseclip (BV); mouth/face mask (MM); and facemask (FM). Ten male runners completed three maximal treadmill tests with breathing assembly randomly assigned. Metabolic and ventilatory data were recorded every 15s, and heart rate (HR) and rating of perceived exertion (RPE) each min. No significant differences were found for treadmill run time, HRmax, respiratory exchange ratio (RER), and RPE, indicating similar efforts on all trials. No significant differences were found at maximal exercise for VO2 minute ventilation (VE), tidal volume (VT), and breathing frequency (f). At ventilatory threshold (TVENT), VO2, VE, and f were not significantly different. However, peak flow (PF) was significantly higher for BV than FM, and VT was significantly higher for BV than MM and FM. Results indicate alterations in ventilatory mechanics occur at TVENT, but type of breathing assembly does not significantly affect maximal values.
Process dependency on threshold voltage of GaN MOSFET on AlGaN/GaN heterostructure
NASA Astrophysics Data System (ADS)
Wang, Qingpeng; Jiang, Ying; Miyashita, Takahiro; Motoyama, Shin-ichi; Li, Liuan; Wang, Dejun; Ohno, Yasuo; Ao, Jin-Ping
2014-09-01
GaN metal-oxide-semiconductor field-effect transistors (MOSFETs) with recessed gate on AlGaN/GaN heterostructure are reported in which the drain and source ohmic contacts were fabricated on the AlGaN/GaN heterostructure and the electron channel was formed on the GaN buffer layer by removing the AlGaN barrier layer. Negative threshold voltages were commonly observed in all devices. To investigate the reasons of the negative threshold voltages, different oxide thickness, etching gas and bias power of inductively-coupled plasma (ICP) system were utilized in the fabrication process of the GaN MOSFETs. It is found that positive charges of around 1 × 1012 q/cm2 exist near the interface at the just threshold condition in both silane- and tetraethylorthosilicate (TEOS)-based devices. It is also found that the threshold voltages do not obviously change with the different etching gas (SiCl4, BCl3 and two-step etching of SiCl4/Cl2) at the same ICP bias power level (20-25 W) and will become deeper when higher bias power is used in the dry recess process which may be related to the much serious ion bombardment damage. Furthermore, X-ray photoelectron spectroscopy (XPS) experiments were done to investigate the surface conditions. It is found that N 1s peaks become lower with higher bias power of the dry etching process. Also, silicon contamination was found and could be removed by HNO3/HF solution. It indicates that the nitrogen vacancies are mainly responsible for the negative threshold voltages rather than the silicon contamination. It demonstrates that optimization of the ICP recess conditions and improvement of the surface condition are still necessary to realize enhancement-mode GaN MOSFETs on AlGaN/GaN heterostructure.
Structure-dependent Pseudoreceptor Intracellular Traffic of Adamantyl Globotriaosyl Ceramide Mimics*
Saito, Mitsumasa; Mylvaganum, Murugespillai; Tam, Patty; Novak, Anton; Binnington, Beth; Lingwood, Clifford
2012-01-01
The verotoxin (VT) (Shiga toxin) receptor globotriaosyl ceramide (Gb3), mediates VT1/VT2 retrograde transport to the endoplasmic reticulum (ER) for cytosolic A subunit access to inhibit protein synthesis. Adamantyl Gb3 is an amphipathic competitive inhibitor of VT1/VT2 Gb3 binding. However, Gb3-negative VT-resistant CHO/Jurkat cells incorporate adaGb3 to become VT1/VT2-sensitive. CarboxyadaGb3, urea-adaGb3, and hydroxyethyl adaGb3, preferentially bound by VT2, also mediate VT1/VT2 cytotoxicity. VT1/VT2 internalize to early endosomes but not to Golgi/ER. AdabisGb3 (two deacyl Gb3s linked to adamantane) protects against VT1/VT2 more effectively than adaGb3 without incorporating into Gb3-negative cells. AdaGb3 (but not hydroxyethyl adaGb3) incorporation into Gb3-positive Vero cells rendered punctate cell surface VT1/VT2 binding uniform and subverted subsequent Gb3-dependent retrograde transport to Golgi/ER to render cytotoxicity (reduced for VT1 but not VT2) brefeldin A-resistant. VT2-induced vacuolation was maintained in adaGb3-treated Vero cells, but vacuolar membrane VT2 was lost. AdaGb3 destabilized membrane cholesterol and reduced Gb3 cholesterol stabilization in phospholipid liposomes. Cholera toxin GM1-mediated Golgi/ER targeting was unaffected by adaGb3. We demonstrate the novel, lipid-dependent, pseudoreceptor function of Gb3 mimics and their structure-dependent modulation of endogenous intracellular Gb3 vesicular traffic. PMID:22418442
A Survey of Architectural Techniques for Near-Threshold Computing
Mittal, Sparsh
2015-12-28
Energy efficiency has now become the primary obstacle in scaling the performance of all classes of computing systems. In low-voltage computing and specifically, near-threshold voltage computing (NTC), which involves operating the transistor very close to and yet above its threshold voltage, holds the promise of providing many-fold improvement in energy efficiency. However, use of NTC also presents several challenges such as increased parametric variation, failure rate and performance loss etc. Our paper surveys several re- cent techniques which aim to offset these challenges for fully leveraging the potential of NTC. By classifying these techniques along several dimensions, we also highlightmore » their similarities and differences. Ultimately, we hope that this paper will provide insights into state-of-art NTC techniques to researchers and system-designers and inspire further research in this field.« less
A Survey of Architectural Techniques for Near-Threshold Computing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mittal, Sparsh
Energy efficiency has now become the primary obstacle in scaling the performance of all classes of computing systems. In low-voltage computing and specifically, near-threshold voltage computing (NTC), which involves operating the transistor very close to and yet above its threshold voltage, holds the promise of providing many-fold improvement in energy efficiency. However, use of NTC also presents several challenges such as increased parametric variation, failure rate and performance loss etc. Our paper surveys several re- cent techniques which aim to offset these challenges for fully leveraging the potential of NTC. By classifying these techniques along several dimensions, we also highlightmore » their similarities and differences. Ultimately, we hope that this paper will provide insights into state-of-art NTC techniques to researchers and system-designers and inspire further research in this field.« less
Investigation of AlGaN/GaN HEMTs degradation with gate pulse stressing at cryogenic temperature
NASA Astrophysics Data System (ADS)
Wang, Ning; Wang, Hui; Lin, Xinpeng; Qi, Yongle; Duan, Tianli; Jiang, Lingli; Iervolino, Elina; Cheng, Kai; Yu, Hongyu
2017-09-01
Degradation on DC characteristics of AlGaN/GaN high electron mobility transistors (HEMTs) after applying pulsed gate stress at cryogenic temperatures is presented in this paper. The nitrogen vacancy near to the AlGaN/GaN interface leads to threshold voltage of stress-free sample shifting positively at low temperature. The anomalous behavior of threshold voltage variation (decrease first and then increase) under gate stressing as compared to stress-free sample is observed when lowing temperature. This can be correlated with the pre-existing electron traps in SiNX layer or at SiNX/AlGaN interface which can be de-activated and the captured electrons inject back to channel with lowering temperature, which counterbalances the influence of nitrogen vacancy on threshold voltage shift.
Back-and-forth micromotion of aqueous droplets in a dc electric field.
Kurimura, Tomo; Ichikawa, Masatoshi; Takinoue, Masahiro; Yoshikawa, Kenichi
2013-10-01
Recently, it was reported that an aqueous droplet in an oil phase exhibited rhythmic back-and-forth motion under stationary dc voltage on the order of 100 V. Here, we demonstrate that the threshold voltage for inducing such oscillation is successfully decreased to the order of 10 V through downsizing of the experimental system. Notably, the threshold electric field tends to decrease with a nonlinear scaling relationship accompanied by the downsizing. We derive a simple theoretical model to interpret the system size dependence of the threshold voltage. This model equation suggests the unique effect of additional noise, which is qualitatively characterized as a coherent resonance by an actual experiment as a kind of coherent resonance. Our result would provide insight into the construction of micrometer-sized self-commutating motors and actuators in microfluidic and micromechanical devices.
NASA Astrophysics Data System (ADS)
Tripathi, Shweta
2016-10-01
In the present work, a two-dimensional (2D) analytical framework of triple material symmetrical gate stack (TMGS) DG-MOSFET is presented in order to subdue the short channel effects. A lightly doped channel along with triple material gate having different work functions and symmetrical gate stack structure, showcases substantial betterment in quashing short channel effects to a good extent. The device functioning amends in terms of improved exemption to threshold voltage roll-off, thereby suppressing the short channel effects. The encroachments of respective device arguments on the threshold voltage of the proposed structure are examined in detail. The significant outcomes are compared with the numerical simulation data obtained by using 2D ATLAS™ device simulator to affirm and formalize the proposed device structure.
NASA Astrophysics Data System (ADS)
Yadav, Dharmendra Singh; Raad, Bhagwan Ram; Sharma, Dheeraj
2016-12-01
In this paper, we focus on the improvement of figures of merit for charge plasma based tunnel field-effect transistor (TFET) in terms of ON-state current, threshold voltage, sub-threshold swing, ambipolar nature, and gate to drain capacitance which provides better channel controlling of the device with improved high frequency response at ultra-low supply voltages. Regarding this, we simultaneously employ work function engineering on the drain and gate electrode of the charge plasma TFET. The use of gate work function engineering modulates the barrier on the source/channel interface leads to improvement in the ON-state current, threshold voltage, and sub-threshold swing. Apart from this, for the first time use of work function engineering on the drain electrode increases the tunneling barrier for the flow of holes on the drain/channel interface, it results into suppression of ambipolar behavior. The lowering of gate to drain capacitance therefore enhanced high frequency parameters. Whereas, the presence of dual work functionality at the gate electrode and over the drain region improves the overall performance of the charge plasma based TFET.
NASA Astrophysics Data System (ADS)
Kumar, Manoj; Haldar, Subhasis; Gupta, Mridula; Gupta, R. S.
2016-10-01
The threshold voltage degradation due to the hot carrier induced localized charges (LC) is a major reliability concern for nanoscale Schottky barrier (SB) cylindrical gate all around (GAA) metal-oxide-semiconductor field-effect transistors (MOSFETs). The degradation physics of gate material engineered (GME)-SB-GAA MOSFETs due to LC is still unexplored. An explicit threshold voltage degradation model for GME-SB-GAA-MOSFETs with the incorporation of localized charges (N it) is developed. To accurately model the threshold voltage the minimum channel carrier density has been taken into account. The model renders how +/- LC affects the device subthreshold performance. One-dimensional (1D) Poisson’s and 2D Laplace equations have been solved for two different regions (fresh and damaged) with two different gate metal work-functions. LCs are considered at the drain side with low gate metal work-function as N it is more vulnerable towards the drain. For the reduction of carrier mobility degradation, a lightly doped channel has been considered. The proposed model also includes the effect of barrier height lowering at the metal-semiconductor interface. The developed model results have been verified using numerical simulation data obtained by the ATLAS-3D device simulator and excellent agreement is observed between analytical and simulation results.
Radiation tolerant back biased CMOS VLSI
NASA Technical Reports Server (NTRS)
Maki, Gary K. (Inventor); Gambles, Jody W. (Inventor); Hass, Kenneth J. (Inventor)
2003-01-01
A CMOS circuit formed in a semiconductor substrate having improved immunity to total ionizing dose radiation, improved immunity to radiation induced latch up, and improved immunity to a single event upset. The architecture of the present invention can be utilized with the n-well, p-well, or dual-well processes. For example, a preferred embodiment of the present invention is described relative to a p-well process wherein the p-well is formed in an n-type substrate. A network of NMOS transistors is formed in the p-well, and a network of PMOS transistors is formed in the n-type substrate. A contact is electrically coupled to the p-well region and is coupled to first means for independently controlling the voltage in the p-well region. Another contact is electrically coupled to the n-type substrate and is coupled to second means for independently controlling the voltage in the n-type substrate. By controlling the p-well voltage, the effective threshold voltages of the n-channel transistors both drawn and parasitic can be dynamically tuned. Likewise, by controlling the n-type substrate, the effective threshold voltages of the p-channel transistors both drawn and parasitic can also be dynamically tuned. Preferably, by optimizing the threshold voltages of the n-channel and p-channel transistors, the total ionizing dose radiation effect will be neutralized and lower supply voltages can be utilized for the circuit which would result in the circuit requiring less power.
Roy, Sharani; Mujica, Vladimiro; Ratner, Mark A
2013-08-21
The scanning tunneling microscope (STM) is a fascinating tool used to perform chemical processes at the single-molecule level, including bond formation, bond breaking, and even chemical reactions. Hahn and Ho [J. Chem. Phys. 123, 214702 (2005)] performed controlled rotations and dissociations of single O2 molecules chemisorbed on the Ag(110) surface at precise bias voltages using STM. These threshold voltages were dependent on the direction of the bias voltage and the initial orientation of the chemisorbed molecule. They also observed an interesting voltage-direction-dependent and orientation-dependent pathway selectivity suggestive of mode-selective chemistry at molecular junctions, such that in one case the molecule underwent direct dissociation, whereas in the other case it underwent rotation-mediated dissociation. We present a detailed, first-principles-based theoretical study to investigate the mechanism of the tunneling-induced O2 dynamics, including the origin of the observed threshold voltages, the pathway dependence, and the rate of O2 dissociation. Results show a direct correspondence between the observed threshold voltage for a process and the activation energy for that process. The pathway selectivity arises from a competition between the voltage-modified barrier heights for rotation and dissociation, and the coupling strength of the tunneling electrons to the rotational and vibrational modes of the adsorbed molecule. Finally, we explore the "dipole" and "resonance" mechanisms of inelastic electron tunneling to elucidate the energy transfer between the tunneling electrons and chemisorbed O2.
Rådman, Lisa; Gunnarsson, Lars-Gunnar; Nilsagård, Ylva; Nilsson, Tohr
2016-12-01
Symptoms described in previous studies indicate that electrical injury can cause longstanding injuries to the neurosensory nerves. The aim of the present case series was to objectively assess the profile of neurosensory dysfunction in electricians in relation to high voltage or low voltage electrical injury and the "no-let-go phenomenon". Twenty-three Swedish male electricians exposed to electrical injury were studied by using a battery of clinical instruments, including quantitative sensory testing (QST). The clinical test followed a predetermined order of assessments: thermal perceptions thresholds, vibration perception thresholds, tactile gnosis (the Shape and Texture Identification test), manual dexterity (Purdue Pegboard Test), and grip strength. In addition, pain was studied by means of a questionnaire, and a colour chart was used for estimation of white fingers. The main findings in the present case series were reduced thermal perceptions thresholds, where half of the group showed abnormal values for warm thermal perception and/or cold thermal perception. Also, the tactile gnosis and manual dexterity were reduced. High voltage injury was associated with more reduced sensibility compared to those with low voltage. Neurosensory injury can be objectively assessed after an electrical injury by using QST with thermal perception thresholds. The findings are consistent with injuries to small nerve fibres. In the clinical setting thermal perception threshold is therefore recommended, in addition to tests of tactile gnosis and manual dexterity (Purdue Pegboard). Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
2014-01-01
Background Previous research combining Calcium β-hydroxy-β-methylbutyrate (CaHMB) and running high-intensity interval training (HIIT) have shown positive effects on aerobic performance measures. The purpose of this study was to examine the effect of β-hydroxy-β-methylbutyric free acid (HMBFA) and cycle ergometry HIIT on maximal oxygen consumption (VO2peak), ventilatory threshold (VT), respiratory compensation point (RCP) and time to exhaustion (Tmax) in college-aged men and women. Methods Thirty-four healthy men and women (Age: 22.7 ± 3.1 yrs ; VO2peak: 39.3 ± 5.0 ml · kg-1 · min-1) volunteered to participate in this double-blind, placebo-controlled design study. All participants completed a series of tests prior to and following treatment. A peak oxygen consumption test was performed on a cycle ergometer to assess VO2peak, Tmax, VT, and RCP. Twenty-six participants were randomly assigned into either a placebo (PLA-HIIT) or 3 g per day of HMBFA (BetaTor™) (HMBFA-HIIT) group. Eight participants served as controls (CTL). Participants in the HIIT groups completed 12 HIIT (80-120% maximal workload) exercise sessions consisting of 5–6 bouts of a 2:1 minute cycling work to rest ratio protocol over a four-week period. Body composition was measured with dual energy x-ray absorptiometry (DEXA). Outcomes were assessed by ANCOVA with posttest means adjusted for pretest differences. Results The HMBFA-HIIT intervention showed significant (p < 0.05) gains in VO2peak, and VT, versus the CTL and PLA-HIIT group. Both PLA-HIIT and HMBFA-HIIT treatment groups demonstrated significant (p < 0.05) improvement over CTL for Tmax, and RCP with no significant difference between the treatment groups. There were no significant differences observed for any measures of body composition. An independent-samples t-test confirmed that there were no significant differences between the training volumes for the PLA-HIIT and HMBFA-HIIT groups. Conclusions Our findings support the use of HIIT in combination with HMBFA to improve aerobic fitness in college age men and women. These data suggest that the addition of HMBFA supplementation may result in greater changes in VO2peak and VT than HIIT alone. Study registration The study was registered on ClinicalTrials.gov (ID NCT01941368). PMID:24782684
Effect of gate bias sweep rate on the threshold voltage of in-plane gate nanowire transistor
NASA Astrophysics Data System (ADS)
Liu, H. X.; Li, J.; Tan, R. R.
2018-01-01
In2O3 nanowire electric-double-layer (EDL) transistors with in-plane gate gated by SiO2 solid-electrolyte are fabricated on transparent glass substrates. The gate voltage sweep rates can effectively modulate the threshold voltage (Vth) of nanowire device. Both depletion mode and enhancement mode are realized, and the Vth shift of the nanowire transistors is estimated to be 0.73V (without light). This phenomenon is due to increased adsorption of oxygen on the nanowire surface by the slower gate voltage sweep rates. Adsorbed oxygens capture electrons and cause a surface of nanowire channel was depleted. The operation voltage of transistor was 1.0 V, because the EDL gate dielectric can lead to high gate dielectric capacitance. These transparent in-plane gate nanowire transistors are promising for “see-through” nanoscale sensors.
Top-gate organic depletion and inversion transistors with doped channel and injection contact
NASA Astrophysics Data System (ADS)
Liu, Xuhai; Kasemann, Daniel; Leo, Karl
2015-03-01
Organic field-effect transistors constitute a vibrant research field and open application perspectives in flexible electronics. For a commercial breakthrough, however, significant performance improvements are still needed, e.g., stable and high charge carrier mobility and on-off ratio, tunable threshold voltage, as well as integrability criteria such as n- and p-channel operation and top-gate architecture. Here, we show pentacene-based top-gate organic transistors operated in depletion and inversion regimes, realized by doping source and drain contacts as well as a thin layer of the transistor channel. By varying the doping concentration and the thickness of the doped channel, we control the position of the threshold voltage without degrading on-off ratio or mobility. Capacitance-voltage measurements show that an inversion channel can indeed be formed, e.g., an n-doped channel can be inverted to a p-type inversion channel with highly p-doped contacts. The Cytop polymer dielectric minimizes hysteresis, and the transistors can be biased for prolonged cycles without a shift of threshold voltage, indicating excellent operation stability.
Tyler, S D; Johnson, W M; Lior, H; Wang, G; Rozee, K R
1991-01-01
A set of synthetic oligonucleotide primers was designed for use in a polymerase chain reaction protocol to specifically detect the B subunit genes in vtx2ha and vtx2hb, which code for the production of the VT2 (Shiga-like toxin II) variant cytotoxins VT2v-a and VT2v-b, respectively. An additional set of primers amplified a fragment common to the B subunits of the VT2 and the VT2 variant genes. Subsequent restriction endonuclease digestion of this amplicon permitted prediction of specific VT2 and variant genotypes on the basis of predetermined restriction fragment length polymorphisms. Genotypes of 21 VT2-producing strains of Escherichia coli were determined using this polymerase chain reaction-restriction fragment length polymorphism procedure. Four strains contained B subunit target sequences only for VT2 genes, 9 strains contained sequences only for VT2v-a genes, and 3 strains contained sequences only for VT2v-b. For genes in combination, one strain contained B subunit genes for both VT2 and VT2v-a and two strains contained B subunit genes for VT2 and VT2v-b. Two strains of E. coli O91:H21 contained both VT2v-a and VT2v-b B subunit genes. The VT2 reference strain of E. coli, E32511, was found to contain the targeted sequences from both VT2 and VT2v-a genes, whereas the recombinant E. coli, pEB1, possessed only that of the VT2 gene. The specific activities of extracellular VT2 determined in HeLa cells ranged from 0.3 to 41.7 TCD50 per microgram of protein in strains carrying the VT2 gene target and from 0 to 50.0 TCD50 per microgram of protein in strains carrying only the VT2 variant target (TCD50 is the tissue culture dose by which 50% of the cells were affected), suggesting that phenotypic expression does not correlate with genotype. Images PMID:1679436
Characteristics of edge breakdowns on Teflon samples
NASA Technical Reports Server (NTRS)
Yadlowsky, E. J.; Hazelton, R. C.; Churchill, R. J.
1980-01-01
The characteristics of electrical discharges induced on silverbacked Teflon samples irradiated by a monoenergetic electron beam have been studied under controlled laboratory conditions. Measurements of breakdown threshold voltages indicate a marked anisotropy in the electrical breakdown properties of Teflon: differences of up to 10 kV in breakdown threshold voltage are observed depending on the sample orientation. The material anisotropy can be utilized in spacecraft construction to reduce the magnitude of discharge currents.
NASA Technical Reports Server (NTRS)
Neudeck, Philip G.; Spry, David J.; Chen, Liangyu
2015-01-01
This work reports a theoretical and experimental study of 4H-SiC JFET threshold voltage as a function of substrate body bias, device position on the wafer, and temperature from 25 C (298K) to 500 C (773K). Based on these results, an alternative approach to SPICE circuit simulation of body effect for SiC JFETs is proposed.
Lee, In-Kyu; Lee, Kwan Hyi; Lee, Seok; Cho, Won-Ju
2014-12-24
We used a microwave annealing process to fabricate a highly reliable biosensor using amorphous-InGaZnO (a-IGZO) thin-film transistors (TFTs), which usually experience threshold voltage instability. Compared with furnace-annealed a-IGZO TFTs, the microwave-annealed devices showed superior threshold voltage stability and performance, including a high field-effect mobility of 9.51 cm(2)/V·s, a low threshold voltage of 0.99 V, a good subthreshold slope of 135 mV/dec, and an outstanding on/off current ratio of 1.18 × 10(8). In conclusion, by using the microwave-annealed a-IGZO TFT as the transducer in an extended-gate ion-sensitive field-effect transistor biosensor, we developed a high-performance biosensor with excellent sensing properties in terms of pH sensitivity, reliability, and chemical stability.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bajaj, Sanyam, E-mail: bajaj.10@osu.edu; Hung, Ting-Hsiang; Akyol, Fatih
2014-12-29
We report on the potential of high electron mobility transistors (HEMTs) consisting of high composition AlGaN channel and barrier layers for power switching applications. Detailed two-dimensional (2D) simulations show that threshold voltages in excess of 3 V can be achieved through the use of AlGaN channel layers. We also calculate the 2D electron gas mobility in AlGaN channel HEMTs and evaluate their power figures of merit as a function of device operating temperature and Al mole fraction in the channel. Our models show that power switching transistors with AlGaN channels would have comparable on-resistance to GaN-channel based transistors for the samemore » operation voltage. The modeling in this paper shows the potential of high composition AlGaN as a channel material for future high threshold enhancement mode transistors.« less
Takeishi, Shunsaku; Rant, Ulrich; Fujiwara, Tsuyoshi; Buchholz, Karin; Usuki, Tatsuya; Arinaga, Kenji; Takemoto, Kazuya; Yamaguchi, Yoshitaka; Tornow, Marc; Fujita, Shozo; Abstreiter, Gerhard; Yokoyama, Naoki
2004-03-22
DNA oligo-nucleotides, localized at Au metal electrodes in aqueous solution, are found to be released when applying a negative bias voltage to the electrode. The release was confirmed by monitoring the intensity of the fluorescence of cyanine dyes (Cy3) linked to the 5' end of the DNA. The threshold voltage of the release changes depending on the kind of linker added to the DNA 3'-terminal. The amount of released DNA depends on the duration of the voltage pulse. Using this technique, we can retain DNA at Au electrodes or Au needles, and release the desired amount of DNA at a precise location in a target. The results suggest that DNA injection into living cells is possible with this method. (c) 2004 American Institute of Physics
Dao, Toan Thanh; Sakai, Heisuke; Nguyen, Hai Thanh; Ohkubo, Kei; Fukuzumi, Shunichi; Murata, Hideyuki
2016-07-20
We present controllable and reliable complementary organic transistor circuits on a PET substrate using a photoactive dielectric layer of 6-[4'-(N,N-diphenylamino)phenyl]-3-ethoxycarbonylcoumarin (DPA-CM) doped into poly(methyl methacrylate) (PMMA) and an electron-trapping layer of poly(perfluoroalkenyl vinyl ether) (Cytop). Cu was used for a source/drain electrode in both the p-channel and n-channel transistors. The threshold voltage of the transistors and the inverting voltage of the circuits were reversibly controlled over a wide range under a program voltage of less than 10 V and under UV light irradiation. At a program voltage of -2 V, the inverting voltage of the circuits was tuned to be at nearly half of the supply voltage of the circuit. Consequently, an excellent balance between the high and low noise margins (NM) was produced (64% of NMH and 68% of NML), resulting in maximum noise immunity. Furthermore, the programmed circuits showed high stability, such as a retention time of over 10(5) s for the inverter switching voltage. Our findings bring about a flexible, simple way to obtain robust, high-performance organic circuits using a controllable complementary transistor inverter.
Hierarchical Approach to 'Atomistic' 3-D MOSFET Simulation
NASA Technical Reports Server (NTRS)
Asenov, Asen; Brown, Andrew R.; Davies, John H.; Saini, Subhash
1999-01-01
We present a hierarchical approach to the 'atomistic' simulation of aggressively scaled sub-0.1 micron MOSFET's. These devices are so small that their characteristics depend on the precise location of dopant atoms within them, not just on their average density. A full-scale three-dimensional drift-diffusion atomistic simulation approach is first described and used to verify more economical, but restricted, options. To reduce processor time and memory requirements at high drain voltage, we have developed a self-consistent option based on a solution of the current continuity equation restricted to a thin slab of the channel. This is coupled to the solution of the Poisson equation in the whole simulation domain in the Gummel iteration cycles. The accuracy of this approach is investigated in comparison to the full self-consistent solution. At low drain voltage, a single solution of the nonlinear Poisson equation is sufficient to extract the current with satisfactory accuracy. In this case, the current is calculated by solving the current continuity equation in a drift approximation only, also in a thin slab containing the MOSFET channel. The regions of applicability for the different components of this hierarchical approach are illustrated in example simulations covering the random dopant-induced threshold voltage fluctuations, threshold voltage lowering, threshold voltage asymmetry, and drain current fluctuations.
NASA Astrophysics Data System (ADS)
Borthakur, Tribeni; Sarma, Ranjit
2017-05-01
Top-contact Pentacene-based organic thin film transistors (OTFTs) with a thin layer of Vanadium Pent-oxide between Pentacene and Au layer are fabricated. Here we have found that the devices with V2O5/Au bi-layer source-drain electrode exhibit better field-effect mobility, high on-off ratio, low threshold voltage and low sub-threshold slope than the devices with Au only. The field-effect mobility, current on-off ratio, threshold voltage and sub-threshold slope of V2O5/Au bi-layer OTFT estimated from the device with 15 nm thick V2O5 layer is .77 cm2 v-1 s-1, 7.5×105, -2.9 V and .36 V/decade respectively.
Durkalec-Michalski, Krzysztof; Zawieja, Emilia E; Podgórski, Tomasz; Łoniewski, Igor; Zawieja, Bogna E; Warzybok, Marta; Jeszka, Jan
2018-01-01
Sodium bicarbonate (SB) has been proposed as an ergogenic aid, as it improves high-intensity and resistance exercise performance. However, no studies have yet investigated SB application in CrossFit. This study examined the effects of chronic, progressive-dose SB ingestion on CrossFit-like performance and aerobic capacity. In a randomized, double-blind, cross-over trial, 21 CrossFit-trained participants were randomly allocated to 2 groups and underwent 2 trials separated by a 14-day washout period. Participants ingested either up to 150 mg∙kg-1 of SB in a progressive-dose regimen or placebo for 10 days. Before and after each trial, Fight Gone Bad (FGB) and incremental cycling (ICT) tests were performed. In order to examine biochemical responses, blood samples were obtained prior to and 3 min after completing each exercise test. No gastrointestinal (GI) side effects were reported during the entire protocol. The overall FGB performance improved under SB by ~6.1% (p<0.001) and it was ~3.1% higher compared to post placebo (PLApost) (p = 0.040). The number of repetitions completed in each round also improved under SB (mean from baseline: +5.8% to +6.4%). Moreover, in ICT, the time to ventilatory threshold (VT) (~8:25 min SBpost vs. ~8:00 min PLApost, p = 0.020), workload at VT (~218 W SBpost vs. ~208 W PLApost, p = 0.037) and heart rate at VT (~165 bpm SBpost vs. ~161 bpm PLApost, p = 0.030) showed higher SBpost than PLApost. Furthermore, the maximum carbon dioxide production increased under SB by ~4.8% (from ~3604 mL∙min-1 to ~3776 mL∙min-1, p = 0.049). Pyruvate concentration and creatine kinase activity before ICT showed higher SBpost than PLApost (~0.32 mmol∙L-1 vs. ~0.26 mmol∙L-1, p = 0.001; ~275 U∙L-1 vs. ~250 U∙L-1, p = 0.010, respectively). However, the small sample size limits the wide-application of our results. Progressive-dose SB ingestion regimen eliminated GI side effects and improved CrossFit-like performance, as well as delayed ventilatory threshold occurrence.
Electrical switching in cadmium boracite single crystals
NASA Technical Reports Server (NTRS)
Takahashi, T.; Yamada, O.
1981-01-01
Cadmium boracite single crystals at high temperatures ( 300 C) were found to exhibit a reversible electric field-induced transition between a highly insulative and a conductive state. The switching threshold is smaller than a few volts for an electrode spacing of a few tenth of a millimeter corresponding to an electric field of 100 to 1000 V/cm. This is much smaller than the dielectric break-down field for an insulator such as boracite. The insulative state reappears after voltage removal. A pulse technique revealed two different types of switching. Unstable switching occurs when the pulse voltage slightly exceeds the switching threshold and is characterized by a pre-switching delay and also a residual current after voltage pulse removal. A stable type of switching occurs when the voltage becomes sufficiently high. Possible device applications of this switching phenomenon are discussed.
Schell, W A; Jones, A M; Garvey, E P; Hoekstra, W J; Schotzinger, R J; Alexander, B D
2017-03-01
The in vitro activities of fungal CYP51 inhibitors VT-1161 and VT-1129 were determined for Candida glabrata ( n = 34) and C. krusei ( n = 50). C. glabrata isolates were screened for FKS gene mutations. All isolates were resistant clinically and/or in vitro to at least one standard antifungal compound. VT-1161 and VT-1129 MICs for all isolates were at least 5-fold below achievable human plasma levels for VT-1161. VT-1161 and VT-1129 are promising for the treatment of resistant C. glabrata and C. krusei infections. Copyright © 2017 American Society for Microbiology.
A theoretical approach to study the optical sensitivity of a MESFET
NASA Astrophysics Data System (ADS)
Dutta, Sutanu
2018-05-01
A theoretical model to study the optical sensitivity of a metal-semiconductor field effect transistor has been proposed for a relatively high drain field. An analytical expression of drain current of the device has been derived for a MESFET under optical illumination considering field dependent mobility of electrons across the channel. The variation of drain current with and without optical illumination has been studied with drain and gate voltages. The optical sensitivity of the drain current has been studied for different biasing conditions and gate lengths. In addition, the shift in threshold voltage of a MESFET under optical illumination is determined and optical sensitivity of the device in terms of its threshold voltage has been studied.
NASA Astrophysics Data System (ADS)
Cazimajou, T.; Legallais, M.; Mouis, M.; Ternon, C.; Salem, B.; Ghibaudo, G.
2018-05-01
We studied the current-voltage characteristics of percolating networks of silicon nanowires (nanonets), operated in back-gated transistor mode, for future use as gas or biosensors. These devices featured P-type field-effect characteristics. It was found that a Lambert W function-based compact model could be used for parameter extraction of electrical parameters such as apparent low field mobility, threshold voltage and subthreshold slope ideality factor. Their variation with channel length and nanowire density was related to the change of conduction regime from direct source/drain connection by parallel nanowires to percolating channels. Experimental results could be related in part to an influence of the threshold voltage dispersion of individual nanowires.
Addressable inverter matrix for process and device characterization
NASA Technical Reports Server (NTRS)
Buehler, M. G.; Sayah, H. R.
1985-01-01
The addressable inverter matrix consists of 222 inverters each accessible with the aid of a shift register. The structure has proven useful in characterizing the variability of inverter transfer curves and in diagnosing processing faults. For good 3-micron CMOS bulk inverters investigated in this study, the percent standard deviation of the inverter threshold voltage was less than one percent and the inverter gain (the slope of the inverter transfer curve at the inverter threshold voltage) was less than 3 percent. The average noise margin for the inverters was near 2 volts for a power supply voltage of 5 volts. The specific faults studied included undersize pull-down transistor widths and various open contacts in the matrix.
Precision Voltage Referencing Techniques in MOS Technology.
NASA Astrophysics Data System (ADS)
Song, Bang-Sup
With the increasing complexity of functions on a single MOS chip, precision analog cicuits implemented in the same technology are in great demand so as to be integrated together with digital circuits. The future development of MOS data acquisition systems will require precision on-chip MOS voltage references. This dissertation will probe two most promising configurations of on-chip voltage references both in NMOS and CMOS technologies. In NMOS, an ion-implantation effect on the temperature behavior of MOS devices is investigated to identify the fundamental limiting factors of a threshold voltage difference as an NMOS voltage source. For this kind of voltage reference, the temperature stability on the order of 20ppm/(DEGREES)C is achievable with a shallow single-threshold implant and a low-current, high-body bias operation. In CMOS, a monolithic prototype bandgap reference is designed, fabricated and tested which embodies a curvature compensation and exhibits a minimized sensitivity to the process parameter variation. Experimental results imply that an average temperature stability on the order of 10ppm/(DEGREES)C with a production spread of less than 10ppm/(DEGREES)C feasible over the commercial temperature range.
NASA Technical Reports Server (NTRS)
MacLeod, Todd C.; Ho, Fat Duen
1999-01-01
The ferroelectric channel in a Metal-Ferroelectric-Semiconductor Field Effect Transistor (MFSFET) can partially change its polarization when the gate voltage near the polarization threshold voltage. This causes the MFSFET Drain current to change with repeated pulses of the same gate voltage near the polarization threshold voltage. A previously developed model [11, based on the Fermi-Dirac function, assumed that for a given gate voltage and channel polarization, a sin-le Drain current value would be generated. A study has been done to characterize the effects of partial polarization on the Drain current of a MFSFET. These effects have been described mathematically and these equations have been incorporated into a more comprehensive mathematical model of the MFSFET. The model takes into account the hysteresis nature of the MFSFET and the time dependent decay as well as the effects of partial polarization. This model defines the Drain current based on calculating the degree of polarization from previous gate pulses, the present Gate voltage, and the amount of time since the last Gate volta-e pulse.
CT volumetry can potentially predict the local stage for gastric cancer after chemotherapy
Wang, Zhi-Cong; Wang, Chen; Ding, Ying; Ji, Yuan; Zeng, Meng-Su; Rao, Sheng-Xiang
2017-01-01
PURPOSE We aimed to evaluate the value of CT tumor volumetry for predicting T and N stages of gastric cancer after chemotherapy, with pathologic results as the reference standard. METHODS This study retrospectively evaluated 42 patients diagnosed with gastric cancer, who underwent chemotherapy followed by surgery. Pre- and post-treatment CT tumor volumes (VT) were measured in portal venous phase and volume reduction ratios were calculated. Correlations between pre- and post-treatment VT, reduction ratio, and pathologic stages were analyzed. Receiver operator characteristic (ROC) analyses were also performed to assess diagnostic performance for prediction of downstaging to T0–2 stage and N0 stage. RESULTS Pretreatment VT, post-treatment VT, and VT reduction ratio were significantly correlated with T stage (rs=0.329, rs=0.546, rs= −0.422, respectively). Post-treatment VT and VT reduction ratio were significantly correlated with N stage (rs=0.442 and rs= −0.376, respectively). Pretreatment VT, post-treatment VT, and VT reduction ratio were significantly different between T0–2 and T3,4 stage tumors (P = 0.05, P < 0.001, and P = 0.002, respectively). The differences between N0 and ≥N1 groups were also statistically significant (P = 0.005 for post-treatment VT, P = 0.016 for VT reduction ratio, respectively). The area under the ROC curve (AUC) for identification of T0–2 groups was 0.70 for pretreatment VT, 0.88 for post-treatment VT, and 0.82 for VT reduction ratio, respectively. AUC was 0.78 for post-treatment VT and 0.74 for VT reduction ratio for identification of N0 groups. CONCLUSION CT tumor volumetry, particularly post-treatment measurement of VT, is potentially valuable for predicting histopathologic T and N stages after chemotherapy in patients with gastric cancer. PMID:28703101
Van, Ngoc Huynh; Lee, Jae-Hyun; Whang, Dongmok; Kang, Dae Joon
2016-06-09
We have successfully synthesized axially doped p- and n-type regions on a single Si nanowire (NW). Diodes and complementary metal-oxide-semiconductor (CMOS) inverter devices using single axial p- and n-channel Si NW field-effect transistors (FETs) were fabricated. We show that the threshold voltages of both p- and n-channel Si NW FETs can be lowered to nearly zero by effectively controlling the doping concentration. Because of the high performance of the p- and n-type Si NW channel FETs, especially with regard to the low threshold voltage, the fabricated NW CMOS inverters have a low operating voltage (<3 V) while maintaining a high voltage gain (∼6) and ultralow static power dissipation (≤0.3 pW) at an input voltage of ±3 V. This result offers a viable way for the fabrication of a high-performance high-density logic circuit using a low-temperature fabrication process, which makes it suitable for flexible electronics.
NASA Technical Reports Server (NTRS)
Asenov, Asen; Kaya, S.
2000-01-01
In this paper we use the Density Gradient (DG) simulation approach to study, in 3-D, the effect of local oxide thickness fluctuations on the threshold voltage of decanano MOSFETs on a statistical scale. The random 2-D surfaces used to represent the interface are constructed using the standard assumptions for the auto-correlation function of the interface. The importance of the Quantum Mechanical effects when studying oxide thickness fluctuations are illustrated in several simulation examples.
McAuliffe, Liam; Parfitt, Gaynor C; Eston, Roger G; Gray, Caitlin; Keage, Hannah A D; Smith, Ashleigh E
2018-01-01
Exercise adherence in already low-active older adults with and without mild cognitive impairment (MCI) remains low. Perceptual regulation and exergaming may facilitate future exercise behaviour by improving the affective experience, however evidence that this population can perceptually regulate is lacking. To explore this, we investigated 1) perceptual regulation of exercise intensity during either exergaming or regular ergometer cycling and 2) explored affective responses. Thirty-two low active older adults (73.9 ± 7.3 years, n = 16, 8 females) with or without MCI (70.9 ± 5.5 years, n = 16, 11 females) participated in a sub-maximal fitness assessment to determine ventilatory threshold (VT) and two experimental sessions (counterbalanced: exergaming or regular ergometer cycling). Experimental sessions consisted 21-min of continuous cycling with 7-min at each: RPE 9, 11 and 13. Oxygen consumption (VO 2 ), heart rate (HR), and affect (Feeling Scale) were obtained throughout the exercise. VO 2 ( p < 0.01) and HR ( p < 0.01) increased linearly with RPE, but were not significantly different between exercise modes or cognitive groups. At RPE 13, participants worked above VT in both modes (exergaming: 115.7 ± 27.3; non-exergaming 114.1 ± 24.3 VO 2 (%VT)). Regardless of cognitive group, affect declined significantly as RPE increased ( p < 0.01). However on average, affect remained pleasant throughout and did not differ between exercise modes or cognitive groups. These results suggest low-active older adults can perceptually regulate exercise intensity, regardless of cognition or mode. At RPE 13, participants regulated above VT, at an intensity that improves cardiorespiratory fitness long-term, and affect remained positive in the majority of participants, which may support long-term physical activity adherence.
Method, memory media and apparatus for detection of grid disconnect
Ye, Zhihong [Clifton Park, NY; Du, Pengwei [Troy, NY
2008-09-23
A phase shift procedure for detecting a disconnect of a power grid from a feeder that is connected to a load and a distributed generator. The phase shift procedure compares a current phase shift of the output voltage of the distributed generator with a predetermined threshold and if greater, a command is issued for a disconnect of the distributed generator from the feeder. To extend the range of detection, the phase shift procedure is used when a power mismatch between the distributed generator and the load exceeds a threshold and either or both of an under/over frequency procedure and an under/over voltage procedure is used when any power mismatch does not exceed the threshold.
Lofrano-Prado, Mara Cristina; Hill, James O; Silva, Humberto José Gomes; Freitas, Camila Rodrigues Menezes; Lopes-de-Souza, Sandra; Lins, Tatiana Acioli; do Prado, Wagner Luiz
2012-04-03
The aim of this study was to determine the acute effects of exercise intensity on anxiety, mood states and hunger in obese adolescents. Subjects were eight male obese adolescents (age 15.44 ± 2.06 y; BMI 33.06 ± 4.78 kg/m2). Each subject underwent three experimental trials: (1) Control, seated for 30 min; (2) Low intensity exercise (LIE)--exercise at 10% below ventilatory threshold (VT); (3) High intensity exercise (HIE)--exercise at 10% above VT. Anxiety (STAI Trait/State), mood (POMS) and hunger (VAS) were assessed before and immediately after the experimental sessions. Comparisons between trials and times were assessed using Kruskal-Wallis and Wilcoxon tests, respectively. Associations between variables were described using a Spearman test. The largest increase in hunger was observed after LEI (914.22%). Both exercise sessions increased anxiety, fatigue and decreased vigor (p < 0.05). Acute exercise bouts are associated with negative changes in anxiety and mood, and with increases in hunger in obese adolescents.
Modeling of Gate Bias Modulation in Carbon Nanotube Field-Effect-Transistors
NASA Technical Reports Server (NTRS)
Yamada, Toshishige; Biegel, Bryan (Technical Monitor)
2002-01-01
The threshold voltages of a carbon nanotube (CNT) field-effect transistor (FET) are derived and compared with those of the metal oxide-semiconductor (MOS) FETs. The CNT channel is so thin that there is no voltage drop perpendicular to the gate electrode plane, which is the CNT diameter direction, and this makes the CNTFET characteristics quite different from those in MOSFETs. The relation between the voltage and the electrochemical potentials, and the mass action law for electrons and holes are examined in the context of CNTs, and it is shown that the familiar relations are still valid because of the macroscopic number of states available in the CNTs. This is in sharp contrast to the cases of quantum dots. Using these relations, we derive an inversion threshold voltage V(sub Ti) and an accumulation threshold voltage V(sub Ta) as a function of the Fermi level E(sub F) in the channel, where E(sub F) is a measure of channel doping. V(sub Ti) of the CNTFETs has a much stronger dependence than that of MOSFETs, while V(sub Ta)s of both CNTFETs and MOSFETs depend quite weakly on E(sub F) with the same functional form. This means the transition from normally-off mode to normally-on mode is much sharper in CNTFETs as the doping increases, and this property has to be taken into account in circuit design.
The effect of ethnicity on the vascular responses to cold exposure of the extremities.
Maley, Matthew J; Eglin, Clare M; House, James R; Tipton, Michael J
2014-11-01
Cold injuries are more prevalent in individuals of African descent (AFD). Therefore, we investigated the effect of extremity cooling on skin blood flow (SkBF) and temperature (T sk) between ethnic groups. Thirty males [10 Caucasian (CAU), 10 Asian (ASN), 10 AFD] undertook three tests in 30 °C air whilst digit T sk and SkBF were measured: (i) vasomotor threshold (VT) test--arm immersed in 35 °C water progressively cooled to 10 °C and rewarmed to 35 °C to identify vasoconstriction and vasodilatation; (ii) cold-induced vasodilatation (CIVD) test--hand immersed in 8 °C water for 30 min followed by spontaneous warming; (iii) cold sensitivity (CS) test--foot immersed in 15 °C water for 2 min followed by spontaneous warming. Cold sensory thresholds of the forearm and finger were also assessed. In the VT test, vasoconstriction and vasodilatation occurred at a warmer finger T sk in AFD during cooling [21.2 (4.4) vs. 17.0 (3.1) °C, P = 0.034] and warming [22.0 (7.9) vs. 12.1 (4.1) °C, P = 0.002] compared with CAU. In the CIVD test, average SkBF during immersion was greater in CAU [42 (24) %] than ASN [25 (8) %, P = 0.036] and AFD [24 (13) %, P = 0.023]. Following immersion, SkBF was higher and rewarming faster in CAU [3.2 (0.4) °C min(-1)] compared with AFD [2.5 (0.7) °C min(-1), P = 0.037], but neither group differed from ASN [3.0 (0.6) °C min(-1)]. Responses to the CS test and cold sensory thresholds were similar between groups. AFD experienced a more intense protracted finger vasoconstriction than CAU during hand immersion, whilst ASN experienced an intermediate response. This greater sensitivity to cold may explain why AFD are more susceptible to cold injuries.
Luther, Vishal; Qureshi, Norman; Lim, Phang Boon; Koa-Wing, Michael; Jamil-Copley, Shahnaz; Ng, Fu Siong; Whinnett, Zachary; Davies, D Wyn; Peters, Nicholas S; Kanagaratnam, Prapa; Linton, Nick
2018-03-01
Postablation reentrant ATs depend upon conducting isthmuses bordered by scar. Bipolar voltage maps highlight scar as sites of low voltage, but the voltage amplitude of an electrogram depends upon the myocardial activation sequence. Furthermore, a voltage threshold that defines atrial scar is unknown. We used Ripple Mapping (RM) to test whether these isthmuses were anatomically fixed between different activation vectors and atrial rates. We studied post-AF ablation ATs where >1 rhythm was mapped. Multipolar catheters were used with CARTO Confidense for high-density mapping. RM visualized the pattern of activation, and the voltage threshold below which no activation was seen. Isthmuses were characterized at this threshold between maps for each patient. Ten patients were studied (Map 1 was AT1; Map 2: sinus 1/10, LA paced 2/10, AT2 with reverse CS activation 3/10; AT2 CL difference 50 ± 30 ms). Point density was similar between maps (Map 1: 2,589 ± 1,330; Map 2: 2,214 ± 1,384; P = 0.31). RM activation threshold was 0.16 ± 0.08 mV. Thirty-one isthmuses were identified in Map 1 (median 3 per map; width 27 ± 15 mm; 7 anterior; 6 roof; 8 mitral; 9 septal; 1 posterior). Importantly, 7 of 31 (23%) isthmuses were unexpectedly identified within regions without prior ablation. AT1 was treated following ablation of 11/31 (35%) isthmuses. Of the remaining 20 isthmuses, 14 of 16 isthmuses (88%) were consistent between the two maps (four were inadequately mapped). Wavefront collision caused variation in low voltage distribution in 2 of 16 (12%). The distribution of isthmuses and nonconducting tissue within the ablated left atrium, as defined by RM, appear concordant between rhythms. This could guide a substrate ablative approach. © 2018 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Hashemi, Adeleh; Bahari, Ali; Ghasemi, Shahram
2017-09-01
In this work, povidone/silica nanocomposite dielectric layers were deposited on the n-type Si (100) substrates for application in n-type silicon field-effect transistors (FET). Thermogravimetric analysis (TGA) indicated that strong chemical interactions between polymer and silica nanoparticles were created. In order to examine the effect of annealing temperatures on chemical interactions and nanostructure properties, annealing process was done at 423-513 K. Atomic force microscopy (AFM) images show the very smooth surfaces with very low surface roughness (0.038-0.088 nm). The Si2p and C1s core level photoemission spectra were deconvoluted to the chemical environments of Si and C atoms respectively. The obtained results of deconvoluted X-ray photoelectron spectroscopy (XPS) spectra revealed a high percentage of silanol hydrogen bonds in the sample which was not annealed. These bonds were inversed to stronger covalence bonds (siloxan bonds) at annealing temperature of 423 K. By further addition of temperature, siloxan bonds were shifted to lower binding energy of about 1 eV and their intensity were abated at annealing temperature of 513 K. The electrical characteristics were extracted from current-Voltage (I-V) and capacitance-voltage (C-V) measurements in metal-insulator-semiconductor (MIS) structure. The all n-type Si transistors showed very low threshold voltages (-0.24 to 1 V). The formation of the strongest cross-linking at nanostructure of dielectric film annealed at 423 K caused resulted in an un-trapped path for the transport of charge carriers yielding the lowest threshold voltage (0.08 V) and the highest electron mobility (45.01 cm2/V s) for its FET. By increasing the annealing temperature (473 and 513 K) on the nanocomposite dielectric films, the values of the average surface roughness, the capacitance and the FET threshold voltage increased and the value of FET electron field-effect mobility decreased.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Niang, K. M.; Flewitt, A. J., E-mail: ajf@eng.cam.ac.uk; Barquinha, P. M. C.
Thin film transistors (TFTs) employing an amorphous indium gallium zinc oxide (a-IGZO) channel layer exhibit a positive shift in the threshold voltage under the application of positive gate bias stress (PBS). The time and temperature dependence of the threshold voltage shift was measured and analysed using the thermalization energy concept. The peak energy barrier to defect conversion is extracted to be 0.75 eV and the attempt-to-escape frequency is extracted to be 10{sup 7} s{sup −1}. These values are in remarkable agreement with measurements in a-IGZO TFTs under negative gate bias illumination stress (NBIS) reported recently (Flewitt and Powell, J. Appl. Phys.more » 115, 134501 (2014)). This suggests that the same physical process is responsible for both PBS and NBIS, and supports the oxygen vacancy defect migration model that the authors have previously proposed.« less
Bidirectional control system for energy flow in solar powered flywheel
NASA Technical Reports Server (NTRS)
Nola, Frank J. (Inventor)
1987-01-01
An energy storage system for a spacecraft is provided which employs a solar powered flywheel arrangement including a motor/generator which, in different operating modes, drives the flywheel and is driven thereby. A control circuit, including a threshold comparator, senses the output of a solar energy converter, and when a threshold voltage is exceeded thereby indicating the availability of solar power for the spacecraft loads, activates a speed control loop including the motor/generator so as to accelerate the flywheel to a constant speed and thereby store mechanical energy, while also supplying energy from the solar converter to the loads. Under circumstances where solar energy is not available and thus the threshold voltage is not exceeded, the control circuit deactivates the speed control loop and activates a voltage control loop that provides for operation of the motor as a generator so that mechanical energy from the flywheel is converted into electrical energy for supply to the spacecraft loads.
A CMOS matrix for extracting MOSFET parameters before and after irradiation
NASA Technical Reports Server (NTRS)
Blaes, B. R.; Buehler, M. G.; Lin, Y.-S.; Hicks, K. A.
1988-01-01
An addressable matrix of 16 n- and 16 p-MOSFETs was designed to extract the dc MOSFET parameters for all dc gate bias conditions before and after irradiation. The matrix contains four sets of MOSFETs, each with four different geometries that can be biased independently. Thus the worst-case bias scenarios can be determined. The MOSFET matrix was fabricated at a silicon foundry using a radiation-soft CMOS p-well LOCOS process. Co-60 irradiation results for the n-MOSFETs showed a threshold-voltage shift of -3 mV/krad(Si), whereas the p-MOSFETs showed a shift of 21 mV/krad(Si). The worst-case threshold-voltage shift occurred for the n-MOSFETs, with a gate bias of 5 V during the anneal. For the p-MOSFETs, biasing did not affect the shift in the threshold voltage. A parasitic MOSFET dominated the leakage of the n-MOSFET biased with 5 V on the gate during irradiation. Co-60 test results for other parameters are also presented.
NASA Astrophysics Data System (ADS)
Wang, Ruo Zheng; Wu, Sheng Li; Li, Xin Yu; Zhang, Jin Tao
2017-07-01
In this study, we set out to fabricate an amorphous indium gallium zinc oxide (a-IGZO) thin-film transistor (TFT) with SiNx/HfO2/SiNx (SHS) sandwiched dielectrics. The J-V and C-V of this SHS film were extracted by the Au/p-Si/SHS/Ti structure. At room temperature the a-IGZO with SHS dielectrics showed the following electrical properties: a threshold voltage of 2.9 V, a subthreshold slope of 0.35 V/decade, an on/off current ratio of 3.5 × 107, and a mobility of 12.8 cm2 V-1 s-1. Finally, we tested the influence of gate bias stress on the TFT, and the result showed that the threshold voltage shifted to a positive voltage when applying a positive gate voltage to the TFT.
Investigation of the novel attributes in double recessed gate SiC MESFETs at drain side
NASA Astrophysics Data System (ADS)
Orouji, Ali A.; Razavi, S. M.; Ebrahim Hosseini, Seyed; Amini Moghadam, Hamid
2011-11-01
In this paper, the potential impact of drain side-double recessed gate (DS-DRG) on silicon carbide (SiC)-based metal semiconductor field effect transistors (MESFETs) is studied. We investigate the device performance focusing on breakdown voltage, threshold voltage, drain current and dc output conductance with two-dimensional and two-carrier device simulation. Our simulation results demonstrate that the channel thickness under the gate in the drain side is an important factor in the breakdown voltage. Also, the positive shift in the threshold voltage for the DS-DRG structure is larger in comparison with that for the source side-double recessed gate (SS-DRG) SiC MESFET. The saturated drain current for the DS-DRG structure is larger compared to that for the SS-DRG structure. The maximum dc output conductance in the DS-DRG structure is smaller than that in the SS-DRG structure.
Choi, Sungjin; Lee, Junhyuk; Kim, Donghyoun; Oh, Seulki; Song, Wangyu; Choi, Seonjun; Choi, Eunsuk; Lee, Seung-Beck
2011-12-01
We report on the fabrication and capacitance-voltage characteristics of double layer nickel-silicide nanocrystals with Si3N4 interlayer tunnel barrier for nano-floating gate memory applications. Compared with devices using SiO2 interlayer, the use of Si3N4 interlayer separation reduced the average size (4 nm) and distribution (+/- 2.5 nm) of NiSi2 nanocrystal (NC) charge traps by more than 50% and giving a two fold increase in NC density to 2.3 x 10(12) cm(-2). The increased density and reduced NC size distribution resulted in a significantly decrease in the distribution of the device C-V characteristics. For each program voltage, the distribution of the shift in the threshold voltage was reduced by more than 50% on average to less than 0.7 V demonstrating possible multi-level-cell operation.
NASA Astrophysics Data System (ADS)
Ueda, Daiki; Takeuchi, Kiyoshi; Kobayashi, Masaharu; Hiramoto, Toshiro
2018-04-01
A new circuit model that provides a clear guide on designing a MOS-gated thyristor (MGT) is reported. MGT plays a significant role in achieving a steep subthreshold slope of a PN-body tied silicon-on-insulator (SOI) FET (PNBTFET), which is an SOI MOSFET merged with an MGT. The effects of design parameters on MGT and the proposed equivalent circuit model are examined to determine how to regulate the voltage response of MGT and how to suppress power dissipation. It is demonstrated that MGT with low threshold voltages, small hysteresis widths, and small power dissipation can be designed by tuning design parameters. The temperature dependence of MGT is also examined, and it is confirmed that hysteresis width decreases with the average threshold voltage kept nearly constant as temperature rises. The equivalent circuit model can be conveniently used to design low-power PNBTFET.
NASA Astrophysics Data System (ADS)
Matsuura, Masahiro; Mano, Takaaki; Noda, Takeshi; Shibata, Naokazu; Hotta, Masahiro; Yusa, Go
2018-02-01
Quantum energy teleportation (QET) is a proposed protocol related to quantum vacuum. The edge channels in a quantum Hall system are well suited for the experimental verification of QET. For this purpose, we examine a charge-density wave packet excited and detected by capacitively coupled front gate electrodes. We observe the waveform of the charge packet, which is proportional to the time derivative of the applied square voltage wave. Further, we study the transmission and reflection behaviors of the charge-density wave packet by applying a voltage to another front gate electrode to control the path of the edge state. We show that the threshold voltages where the dominant direction is switched in either transmission or reflection for dense and sparse wave packets are different from the threshold voltage where the current stops flowing in an equilibrium state.
Negative differential conductance in doped-silicon nanoscale devices with superconducting electrodes
NASA Astrophysics Data System (ADS)
Shapovalov, A.; Shaternik, V.; Suvorov, O.; Zhitlukhina, E.; Belogolovskii, M.
2018-02-01
We present a proof-of-concept nanoelectronics device with a negative differential conductance, an attractive from the applied viewpoint functionality. The device, characterized by the decreasing current with increasing voltage in a certain voltage region above a threshold bias of about several hundred millivolts, consists of two superconducting electrodes with an amorphous 10-nm-thick silicon interlayer doped by tungsten nano-inclusions. We show that small changes in the W content radically modify the shape of the trilayer current-voltage dependence and identify sudden conductance switching at a threshold voltage as an effect of Andreev fluctuators. The latter entities are two-level systems at the superconductor-doped silicon interface where a Cooper pair tunnels from a superconductor and occupies a pair of localized electronic states. We argue that in contrast to previously proposed devices, our samples permit very large-scale integration and are practically feasible.
NASA Astrophysics Data System (ADS)
Shrestha, Niraj M.; Li, Yiming; Chang, E. Y.
2016-07-01
Normally-off AlGaN/GaN high electron mobility transistors (HEMTs) are indispensable devices for power electronics as they can greatly simplify circuit designs in a cost-effective way. In this work, the electrical characteristics of p-type InAlN gate normally-off AlGaN/GaN HEMTs with a step buffer layer of Al0.25Ga0.75N/Al0.1Ga0.9N is studied numerically. Our device simulation shows that a p-InAlN gate with a step buffer layer allows the transistor to possess normally-off behavior with high drain current and high breakdown voltage simultaneously. The gate modulation by the p-InAlN gate and the induced holes appearing beneath the gate at the GaN/Al0.25Ga0.75N interface is because a hole appearing in the p-InAlN layer can effectively vary the threshold voltage positively. The estimated threshold voltage of the normally-off HEMTs explored is 2.5 V at a drain bias of 25 V, which is 220% higher than the conventional p-AlGaN normally-off AlGaN/GaN gate injection transistor (GIT). Concurrently, the maximum current density of the explored HEMT at a drain bias of 10 V slightly decreases by about 7% (from 240 to 223 mA mm-1). At a drain bias of 15 V, the current density reached 263 mA mm-1. The explored structure is promising owing to tunable positive threshold voltage and the maintenance of similar current density; notably, its breakdown voltage significantly increases by 36% (from 800 V, GIT, to 1086 V). The engineering findings of this study indicate that novel p-InAlN for both the gate and the step buffer layer can feature a high threshold voltage, large current density and high operating voltage for advanced AlGaN/GaN HEMT devices.
NASA Astrophysics Data System (ADS)
Lee, Kin Kiong; Wang, Danna; Shinobu, Onoda; Ohshima, Takeshi
2018-04-01
Radiation-induced charge trapping and interface traps in n-channel ZnO thin film transistors are characterised as a function of total dose and irradiation bias following exposure to gamma-rays. Devices were irradiated up to ∼60 kGy(SiO?) and the electrical characteristic exhibits two distinct regimes. In the first regime, up to a total dose of 40 kGy(SiO?), the threshold voltage increases positively. However, in the second regime with irradiation greater than 40 kGy(SiO?), the threshold voltage moves in the opposite direction. This reversal of threshold voltage is attributed to the influence of the radiation-induced interface and oxide- charge, in which both have opposite polarity, on the electrical performance of the transistors. In the first regime, the generation of the oxide- charge is initially greater than the density of interface traps and caused a positive shift. In the second regime, when the total doses were greater than 40 kGy(SiO?), the radiation-induced interface traps are greater than the density of oxide- charge and caused the threshold voltage to switch direction. Further, the generated interface traps contributed to the degradation of the effective channel mobility, whereas the density of traps at the grain-boundaries did not increase significantly upon irradiation. Isothermal annealing of the devices at 363 K results in a reduction in the trap density and an improvement of the effective channel mobility to ∼90% of its pre-irradiation value.
Graphics Software For VT Terminals
NASA Technical Reports Server (NTRS)
Wang, Caroline
1991-01-01
VTGRAPH graphics software tool for DEC/VT computer terminal or terminals compatible with it, widely used by government and industry. Callable in FORTRAN or C language, library program enabling user to cope with many computer environments in which VT terminals used for window management and graphic systems. Provides PLOT10-like package plus color or shade capability for VT240, VT241, and VT300 terminals. User can easily design more-friendly user-interface programs and design PLOT10 programs on VT terminals with different computer systems. Requires ReGis graphics set terminal and FORTRAN compiler.
Jin, Qi; Jacobsen, Peter Karl; Pehrson, Steen; Chen, Xu
2017-11-01
Ventricular tachycardia (VT) recurrence after catheter ablation for electrical storm is commonly seen in patients with ischemic cardiomyopathy (ICM). We hypothesized that VT recurrence can be predicted and be related to the all-cause death after VT storm ablation guided by remote magnetic navigation (RMN) in patients with ICM. A total of 54 ICM patients (87% male; mean age, 65 ± 7.1 years) presenting with VT storm undergoing acute ablation using RMN were enrolled. Acute complete ablation success was defined as noninducibility of any sustained monomorphic VT at the end of the procedure. Early VT recurrence was defined as the occurrence of sustained VT within 1 month after the first ablation. After a mean follow-up of 17.1 months, 27 patients (50%) had freedom from VT recurrence. Sustained VT recurred in 12 patients (22%) within 1 month following the first ablation. In univariate analysis, VT recurrence was associated with incomplete procedural success (hazard ratio [HR]: 6.25, 95% confidence interval [CI]: 1.20-32.47, P = 0.029), lack of amiodarone usage before ablation (HR: 4.71, 95% CI: 1.12-19.7, P = 0.034), and a longer procedural time (HR: 1.023, 95% CI: 1.00-1.05, P = 0.05). The mortality of patients with early VT recurrence was higher than that of patients without recurrence (P < 0.01). Inducibility of any VT at the end of procedure for VT storm guided by RMN is the strongest predictor of VT recurrence. ICM patients who have early recurrences after VT storm ablation are at high risk of all-cause death. © 2017 Wiley Periodicals, Inc.
Hong, Caron M; Xu, Da-Zhong; Lu, Qi; Cheng, Yunhui; Pisarenko, Vadim; Doucet, Danielle; Brown, Margaret; Aisner, Seena; Zhang, Chunxiang; Deitch, Edwin A; Delphin, Ellise
2010-06-01
Protective mechanical ventilation with low tidal volume (Vt) and low plateau pressure reduces mortality and decreases the length of mechanical ventilation in patients with acute respiratory distress syndrome. Mechanical ventilation that will protect normal lungs during major surgical procedures of long duration may improve postoperative outcomes. We performed an animal study comparing 3 ventilation strategies used in the operating room in normal lungs. We compared the effects on pulmonary mechanics, inflammatory mediators, and lung tissue injury. Female pigs were randomized into 3 groups. Group H-Vt/3 (n = 6) was ventilated with a Vt of 15 mL/kg predicted body weight (PBW)/positive end-expiratory pressure (PEEP) of 3 cm H(2)O, group L-Vt/3 (n = 6) with a Vt of 6 mL/kg PBW/PEEP of 3 cm H(2)O, and group L-Vt/10 (n = 6) with a Vt of 6 mL/kg PBW/PEEP of 10 cm H(2)O, for 8 hours. Hemodynamics, airway mechanics, arterial blood gases, and inflammatory markers were monitored. Bronchoalveolar lavage (BAL) was analyzed for inflammatory markers and protein concentration. The right lower lobe was assayed for mRNA of specific cytokines. The right lower lobe and right upper lobe were evaluated histologically. In contrast to groups H-Vt/3 and L-Vt/3, group L-Vt/10 exhibited a 6-fold increase in inflammatory mediators in BAL (P < 0.001). Cytokines in BAL were similar in groups H-Vt/3 and L-Vt/3. Group H-Vt/3 had a significantly lower lung injury score than groups L-Vt/3 and L-Vt/10. Comparing intraoperative strategies, ventilation with high PEEP resulted in increased production of inflammatory markers. Low PEEP resulted in lower levels of inflammatory markers. High Vt/low PEEP resulted in less histologic lung injury.
Histopathology of tympanic membranes from patients with ventilation tubes.
Oktay, Mehmet Faruk; Tansuker, Hasan Deniz; Fukushima, Hisaki; Paparella, Michael M; Schachern, Patricia A; Cureoglu, Sebahattin
2018-06-01
To evaluate the histopathologic changes in tympanic membranes (TMs) with ventilation tubes (VTs). In this retrospective human temporal bone study our overall study group included 4 subgroups of TMs from deceased donors as follows: 24 with a history of VT insertion for chronic otitis media with effusion (COME-VT); 5 with a history of VT insertion for Meniere's disease (MD-VT); 33 without a history of VT insertion for chronic otitis media with effusion (COME); and 14 without a history of VT insertion for Meniere's disease (MD). We classified the extent of migration of the outer keratinized squamous epithelium onto the inner surface of TM perforations and noted the presence and location of tympanosclerosis, of atrophy, of perforation, and/or of cholesteatoma formation. Tympanosclerosis occurred in 14/24 TMs in the COME-VT subgroup; 2/5, MD-VT; 7/33, COME; and 0/14, MD. The VT insertion site was mostly in the anteroinferior (63%) quadrant of the TM; tympanosclerosis occurred more frequently in the posteroinferior (42%) and posterosuperior (33%) quadrants. We found no significant correlation between the location of tympanosclerosis and the VT insertion site (P>0.05). Atrophy occurred in 7/24 TMs in the COME-VT subgroup; 3/5, MD-VT; 8/33, COME; and 2/14, MD. We found no significant correlation between the location of atrophy and the VT insertion site; however, atrophy was located mostly in the anteroinferior quadrant (one of the most common VT insertion sites) of the TM. Regarding the ingrowth of keratinized epithelium, the mucocutanous junction was detected at any point at the inner surface of the TM in 50% of the specimens. We observed intratympanic cholesteatoma formation in 2/24 TMs in the COME-VT subgroup. TM changes due to VT insertion are more common than previously realized. Meticulous otomicroscopic evaluation of the TM is necessary during tympanomastoidectomies in order to prevent the intratympanic inclusion pearls and squamous epithelial ingrowth to prevent any further cholesteatoma formation. Copyright © 2017. Published by Elsevier B.V.
Electronic circuit provides accurate sensing and control of dc voltage
NASA Technical Reports Server (NTRS)
Loftus, W. D.
1966-01-01
Electronic circuit used relay coil to sense and control dc voltage. The control relay is driven by a switching transistor that is biased to cutoff for all input up to slightly less than the threshold level.
Upsets in Erased Floating Gate Cells With High-Energy Protons
Gerardin, S.; Bagatin, M.; Paccagnella, A.; ...
2017-01-01
We discuss upsets in erased floating gate cells, due to large threshold voltage shifts, using statistical distributions collected on a large number of memory cells. The spread in the neutral threshold voltage appears to be too low to quantitatively explain the experimental observations in terms of simple charge loss, at least in SLC devices. The possibility that memories exposed to high energy protons and heavy ions exhibit negative charge transfer between programmed and erased cells is investigated, although the analysis does not provide conclusive support to this hypothesis.
Analysis of the instability underlying electrostatic suppression of the Leidenfrost state
NASA Astrophysics Data System (ADS)
Shahriari, Arjang; Das, Soumik; Bahadur, Vaibhav; Bonnecaze, Roger T.
2017-03-01
A liquid droplet on a hot solid can generate enough vapor to prevent its contact on the surface and reduce the rate of heat transfer, the so-called Leidenfrost effect. We show theoretically and experimentally that for a sufficiently high electrostatic potential on the droplet, the formation of the vapor layer is suppressed. The interplay of the destabilizing electrostatic force and stabilizing capillary force and evaporation determines the minimum or threshold voltage to suppress the Leidenfrost effect. Linear stability theory accurately predicts threshold voltages for different size droplets and varying temperatures.
NASA Astrophysics Data System (ADS)
Amrani, Aumeur El; Es-saghiri, Abdeljabbar; Boufounas, El-Mahjoub; Lucas, Bruno
2018-06-01
The performance of a pentacene based organic thin film transistor (OTFT) with polymethylmethacrylate as a dielectric insulator and indium tin oxide based electrical gate is investigated. On the one hand, we showed that the threshold voltage increases with gate voltage, and on the other hand that it decreases with drain voltage. Thus, we noticed that the onset voltage shifts toward positive voltage values with the drain voltage increase. In addition, threshold-onset differential voltage (TODV) is proposed as an original approach to estimate an averaged carrier density in pentacene. Indeed, a value of about 4.5 × 1016 cm-3 is reached at relatively high gate voltage of -50 V; this value is in good agreement with that reported in literature with other technique measurements. However, at a low applied gate voltage, the averaged pentacene carrier density remains two orders of magnitude lower; it is of about 2.8 × 1014 cm-3 and remains similar to that obtained from space charge limited current approach for low applied bias voltage of about 2.2 × 1014 cm-3. Furthermore, high IOn/IOff and IOn/IOnset current ratios of 5 × 106 and 7.5 × 107 are reported for lower drain voltage, respectively. The investigated OTFTs also showed good electrical performance including carrier mobility increasing with gate voltage; mobility values of 4.5 × 10-2 cm2 V-1 s-1 and of 4.25 × 10-2 cm2 V-1 s-1 are reached for linear and saturation regimes, respectively. These results remain enough interesting since current modulation ratio exceeds a value of 107 that is a quite important requirement than high mobility for some particular logic gate applications.
NASA Technical Reports Server (NTRS)
Javadi, Hamid (Inventor)
2001-01-01
A device to protect electronic circuitry from high voltage transients is constructed from a relatively thin piece of conductive composite sandwiched between two conductors so that conduction is through the thickness of the composite piece. The device is based on the discovery that conduction through conductive composite materials in this configuration switches to a high resistance mode when exposed to voltages above a threshold voltage.
NASA Technical Reports Server (NTRS)
Javadi, Hamid (Inventor)
2002-01-01
A device to protect electronic circuitry from high voltage transients is constructed from a relatively thin piece of conductive composite sandwiched between two conductors so that conduction is through the thickness of the composite piece. The device is based on the discovery that conduction through conductive composite materials in this configuration switches to a high resistance mode when exposed to voltages above a threshold voltage.
Chen, Qiusong; Jia, Weiyao; Chen, Lixiang; Yuan, De; Zou, Yue; Xiong, Zuhong
2016-01-01
Lowering the driving voltage of organic light-emitting diodes (OLEDs) is an important approach to reduce their energy consumption. We have fabricated a series of bifunctional devices (OLEDs and photovoltaics) using rubrene and fullerene (C60) as the active layer, in which the electroluminescence threshold voltage(~1.1 V) was half the value of the bandgap of rubrene. Magneto-electroluminescence (MEL) response of planner heterojunction diodes exhibited a small increase in response to a low magnetic field strength (<20 mT); however, a very large decay was observed at a high magnetic field strength (>20 mT). When a hole-transport layer with a low mobility was included in these devices, the MEL response reversed in shape, and simultaneously, the EL threshold voltage became larger than the bandgap voltage. When bulk heterojunction device was examined, the amplitude of MEL curves presented an anomalous voltage-dependence. Following an analysis of the MEL responses of these devices, we proposed that the EL of half-bandgap-voltage device originated from bimolecular triplet-triplet annihilation in the rubrene film, rather than from singlet excitons that formed via an interface auger recombination. This work provides critical insight into the mechanisms of OLED emission and will help advance the applications of bifunctional devices. PMID:27142285
High Performance Complementary Circuits Based on p-SnO and n-IGZO Thin-Film Transistors.
Zhang, Jiawei; Yang, Jia; Li, Yunpeng; Wilson, Joshua; Ma, Xiaochen; Xin, Qian; Song, Aimin
2017-03-21
Oxide semiconductors are regarded as promising materials for large-area and/or flexible electronics. In this work, a ring oscillator based on n-type indium-gallium-zinc-oxide (IGZO) and p-type tin monoxide (SnO) is presented. The IGZO thin-film transistor (TFT) shows a linear mobility of 11.9 cm²/(V∙s) and a threshold voltage of 12.2 V. The SnO TFT exhibits a mobility of 0.51 cm²/(V∙s) and a threshold voltage of 20.1 V which is suitable for use with IGZO TFTs to form complementary circuits. At a supply voltage of 40 V, the complementary inverter shows a full output voltage swing and a gain of 24 with both TFTs having the same channel length/channel width ratio. The three-stage ring oscillator based on IGZO and SnO is able to operate at 2.63 kHz and the peak-to-peak oscillation amplitude reaches 36.1 V at a supply voltage of 40 V. The oxide-based complementary circuits, after further optimization of the operation voltage, may have wide applications in practical large-area flexible electronics.
High Performance Complementary Circuits Based on p-SnO and n-IGZO Thin-Film Transistors
Zhang, Jiawei; Yang, Jia; Li, Yunpeng; Wilson, Joshua; Ma, Xiaochen; Xin, Qian; Song, Aimin
2017-01-01
Oxide semiconductors are regarded as promising materials for large-area and/or flexible electronics. In this work, a ring oscillator based on n-type indium-gallium-zinc-oxide (IGZO) and p-type tin monoxide (SnO) is presented. The IGZO thin-film transistor (TFT) shows a linear mobility of 11.9 cm2/(V∙s) and a threshold voltage of 12.2 V. The SnO TFT exhibits a mobility of 0.51 cm2/(V∙s) and a threshold voltage of 20.1 V which is suitable for use with IGZO TFTs to form complementary circuits. At a supply voltage of 40 V, the complementary inverter shows a full output voltage swing and a gain of 24 with both TFTs having the same channel length/channel width ratio. The three-stage ring oscillator based on IGZO and SnO is able to operate at 2.63 kHz and the peak-to-peak oscillation amplitude reaches 36.1 V at a supply voltage of 40 V. The oxide-based complementary circuits, after further optimization of the operation voltage, may have wide applications in practical large-area flexible electronics. PMID:28772679
Serrano-Pinto, Vania; Vazquez-Boucard, Celia; Villarreal-Colmenares, Humberto
2003-01-01
Vitellins from ovaries and eggs at different stages of development in freshwater crayfish (Cherax quadricarinatus) were examined by chromatography, PAGE and SDS-PAGE. With these methods, two forms of vitellin (Vt1 and Vt2) were observed in ovaries and eggs (stages I and V). In ovaries in secondary vitellogenesis, native molecular mass was 470 (Vt1) and 440 (Vt2) kDa. The electrophoretic pattern of the eggs proved to be more complex. The protein molecular mass depend on the development stage of the egg: stage I, 650 kDa (Vt1) and 440 kDa (Vt2); stage V, 390 kDa (Vt1) and 340 kDa (Vt2). The identified vitellins appear to be lipo-glycocarotenoprotein. A similar vitellin polypeptide composition was observed in the two forms of vitellin from ovaries and eggs in stage V. In ovaries the SDS-PAGE analysis showed four subunits with molecular weights of approximately 180, 120, 95 and 80 kDa (Vt1 and Vt2). The polypeptide composition in the two forms of vitellins in stage I and stage III eggs were different at 195, 190, 130 and 110 kDa (Vt1) and 116 and 107 kDa (Vt2). On the other hand, in stage V eggs, 110, 95, 87 and 75 kDa (Vt1 and Vt2) were identified. Two antibodies (Ab1 and Ab2) were prepared against the purified proteins of stage V eggs and their specificity was demonstrated by radial immunoprecipitation, and Western blotting analysis. Two forms of vitellins were also found in stage V eggs after chromatography on Sepharose CL-2B column and hydroxylapatite and polyacrylamide gel electrophoresis.
Break, Timothy J; Desai, Jigar V; Ferre, Elise M N; Henderson, Christina; Zelazny, Adrian M; Siebenlist, Ulrich; Hoekstra, William J; Schotzinger, Robert J; Garvey, Edward P; Lionakis, Michail S
2018-01-01
Abstract Background Candida albicans, the most common human fungal pathogen, causes chronic mucosal infections in patients with inborn errors of IL-17 immunity that rely heavily on chronic, often lifelong, azole antifungal agents for treatment. However, a rise in azole resistance has predicated a need for developing new antifungal drugs. Objectives To test the in vitro and in vivo efficacy of VT-1161 and VT-1129 in the treatment of oropharyngeal candidiasis with azole-susceptible or -resistant C. albicans strains. Methods MICs of VT-1161, VT-1129 and nine licensed antifungal drugs were determined for 31 Candida clinical isolates. The drug concentrations in mouse serum and tongues were measured following oral administration. IL-17-signalling-deficient Act1−/− mice were infected with fluconazole-susceptible or fluconazole-resistant C. albicans strains, and the amount of mucosal fungal burden was determined after fluconazole or VT-1161 treatment. Results Fourteen isolates (45%) were not fluconazole susceptible (MIC ≥4 mg/L). VT-1161 and VT-1129 showed significant in vitro activity against the majority of the 31 mucosal clinical isolates (MIC50 0.03 and 0.06 mg/L, respectively), including Candida glabrata (MIC50, 0.125 and 0.25 mg/L, respectively). After oral doses, VT-1161 and VT-1129 concentrations in mouse serum and tongues were well above their MIC50 values. VT-1161 was highly effective as treatment of both fluconazole-susceptible and -resistant oropharyngeal candidiasis in Act1−/− mice. Conclusions VT-1129 and VT-1161 exhibit significant in vitro activity against Candida strains, including fluconazole-resistant C. albicans and C. glabrata. VT-1161 administration in mice results in significant mucosal drug accumulation and eradicates infection caused by fluconazole-susceptible and -resistant Candida strains. PMID:29040636
Relationships Between Glycemic Control and Cardiovascular Fitness.
Moxley, Elizabeth W; Smith, Donald; Quinn, Lauretta; Park, Chang
2018-07-01
Diabetes is a serious health problem affecting approximately 29.1 million individuals in the United States. Another 86 million have prediabetes. The development and implementation of lifestyle modifications such as physical activity for these persons are among the most effective methods for prevention and treatment. The aim of this study was to examine relationships between glycemic control (HbA1c) and cardiovascular fitness (peak maximal oxygen uptake [VO 2 peak] and ventilatory threshold [VT]) in overweight/obese subjects with and without type 2 diabetes (T2DM). In addition, the influences of body mass index (BMI) and insulin sensitivity (homeostasis model assessment [HOMA %S]) on the relationship between glycemic control and cardiovascular fitness were explored. Data were abstracted from a completed study that included 51 overweight or obese subjects with T2DM ( n = 18), impaired glucose tolerance ( n = 8), or normal glucose tolerance ( n = 25). Relationships between glycemic control (HbA1c) and cardiovascular fitness (VO 2 peak and VT) were determined using correlational analysis and multiple linear regression analyses. A statistically significant relationship was observed between HbA1c and cardiovascular fitness. However, BMI and HOMA %S did not influence the relationship between glycemic control and cardiovascular fitness. HbA1c contributes to VO 2 peak and VT in obese and overweight subjects across glucose tolerance categories. Significant results were achieved despite the fact that there was a limited range of HbA1c based on the study inclusion criteria. This finding suggests that even a mild decrease in glycemic control can negatively influence cardiovascular fitness.
Forbes, Scott C; Sletten, Nathan; Durrer, Cody; Myette-Côté, Étienne; Candow, D; Little, Jonathan P
2017-06-01
High-intensity interval training (HIIT) has been shown to improve cardiorespiratory fitness, performance, body composition, and insulin sensitivity. Creatine (Cr) supplementation may augment responses to HIIT, leading to even greater physiological adaptations. The purpose of this study was to determine the effects of 4 weeks of HIIT (three sessions/week) combined with Cr supplementation in recreationally active females. Seventeen females (age = 23 ± 4 yrs; BMI = 23.4 ± 2.4) were randomly assigned to either Cr (Cr; 0.3 g・kg -1 ・d -1 for 5 d followed by 0.1 g・kg -1 ・d -1 for 23 days; n = 9) or placebo (PLA; n = 8). Before and after the intervention, VO 2peak , ventilatory threshold (VT), time-trial performance, lean body mass and fat mass, and insulin sensitivity were assessed. HIIT improved VO 2peak (Cr = +10.2%; PLA = +8.8%), VT (Cr = +12.7%; PLA = +9.9%), and time-trial performance (Cr = -11.5%; PLA = -11.6%) with no differences between groups (time main effects, all p < .001). There were no changes over time for fat mass (Cr = -0.3%; PLA = +4.3%), whole-body lean mass (Cr = +0.5%; PLA = -0.9%), or insulin resistance (Cr = +3.9%; PLA = +18.7%). In conclusion, HIIT is an effective way to improve cardiorespiratory fitness, VT, and time-trial performance. The addition of Cr to HIIT did not augment improvements in cardiorespiratory fitness, performance or body composition in recreationally active females.
Mendonca, Goncalo V; Teixeira, Micael S; Heffernan, Kevin S; Fernhall, Bo
2013-06-01
Ingestion of water attenuates the chronotropic response to submaximal exercise. However, it is not known whether this effect is equally manifested during dynamic exercise below and above the ventilatory threshold (VT). We explored the effects of water ingestion on the heart rate response to an incremental cycle-ergometer protocol. In a randomized fashion, 19 healthy adults (10 men and nine women, age 20.9 ± 1.8 years) ingested 50 and 500 ml of water before completing a cycle-ergometer protocol on two separate days. The heart rate and oxygen uptake ( ) responses to water ingestion were analysed both at rest and during exercise performed below and above the VT. The effects of water intake on brachial blood pressure were measured only at rest. Resting mean arterial pressure increased and resting heart rate decreased, but only after 500 ml of water (P < 0.05). Compared with that seen after 50 ml of water, the 500 ml volume elicited an overall decrease in submaximal heart rate (P < 0.05). In contrast, drinking 500 ml of water did not affect submaximal . The participants' maximal heart rate, maximal and VT were similar between conditions. Our results therefore indicate that, owing to its effects on submaximal heart rate over a broad spectrum of intensities, the drinking of water should be recognized as a potential confounder in cardiovascular exercise studies. However, by showing no differences between conditions for submaximal , they also suggest that the magnitude of heart rate reduction after drinking 500 ml of water may be of minimal physiological significance for exercise cardiorespiratory capacity.
OBSAPS Data Acquisition System: Operator’s Manual and System Overview
2011-05-01
Explanation of Druck Voltage to Depth Conversion used during OBSAPS (April-May’11) 25 Druck Pressure sensor conversion from...for H-91, PA Voltage, PA Current and Sonobuoy and Druck pressure sensor analog inputs. 6. Software settable thresholds for H-91, PA Voltage, PA...17. Custom dry side box for Druck Pressure Sensor supply voltage and dropping resistor. 18. Battery 9-30VDC for supplying Druck power 19. Druck PTX
Measuring Input Thresholds on an Existing Board
NASA Technical Reports Server (NTRS)
Kuperman, Igor; Gutrich, Daniel G.; Berkun, Andrew C.
2011-01-01
A critical PECL (positive emitter-coupled logic) interface to Xilinx interface needed to be changed on an existing flight board. The new Xilinx input interface used a CMOS (complementary metal-oxide semiconductor) type of input, and the driver could meet its thresholds typically, but not in worst-case, according to the data sheet. The previous interface had been based on comparison with an external reference, but the CMOS input is based on comparison with an internal divider from the power supply. A way to measure what the exact input threshold was for this device for 64 inputs on a flight board was needed. The measurement technique allowed an accurate measurement of the voltage required to switch a Xilinx input from high to low for each of the 64 lines, while only probing two of them. Directly driving an external voltage was considered too risky, and tests done on any other unit could not be used to qualify the flight board. The two lines directly probed gave an absolute voltage threshold calibration, while data collected on the remaining 62 lines without probing gave relative measurements that could be used to identify any outliers. The PECL interface was forced to a long-period square wave by driving a saturated square wave into the ADC (analog to digital converter). The active pull-down circuit was turned off, causing each line to rise rapidly and fall slowly according to the input s weak pull-down circuitry. The fall time shows up as a change in the pulse width of the signal ready by the Xilinx. This change in pulse width is a function of capacitance, pulldown current, and input threshold. Capacitance was known from the different trace lengths, plus a gate input capacitance, which is the same for all inputs. The pull-down current is the same for all inputs including the two that are probed directly. The data was combined, and the Excel solver tool was used to find input thresholds for the 62 lines. This was repeated over different supply voltages and temperatures to show that the interface had voltage margin under all worst case conditions. Gate input thresholds are normally measured at the manufacturer when the device is on a chip tester. A key function of this machine was duplicated on an existing flight board with no modifications to the nets to be tested, with the exception of changes in the FPGA program.
NASA Astrophysics Data System (ADS)
Kim, Youngjun; Cho, Seongeun; Park, Byoungnam
2018-03-01
We report ultraviolet (UV)-induced optical gating in a Zn1-x Mg x O nanocrystal solid solution (NCSS) field effect transistor (FET) through a systematic study in which UV-induced charge transport properties are probed as a function of Mg composition. Change in the electrical properties of Zn1-x Mg x O NCSS associated with electronic traps is investigated by field effect-modulated current-voltage characteristic curves in the dark and under illumination. Under UV illumination, significant threshold voltage shift to a more negative value in an n-channel Zn1-x Mg x O NCSS FET is observed. Importantly, as the Mg composition increases, the effect of UV illumination on the threshold voltage shift is alleviated. We found that threshold voltage shift as a function of Mg composition in the dark and under illumination is due to difference in the deep trap density in the Zn1-x Mg x O NCSS. This is supported by Mg composition dependent photoluminescence intensity in the visible range and reduced FET mobility with Mg addition. The presence of the deep traps and the corresponding trap energy levels in the Zn1-x Mg x O NCSS are ensured by photoelectron spectroscopy in air.
Design and construction of a home-made and cheaper argon arc lamp
NASA Astrophysics Data System (ADS)
Sabaeian, Mohammad; Nazari-Tarkarani, Zeinab; Ebrahimzadeh, Azadeh
2018-05-01
The authors report on the design and construction of an argon arc lamp which provides noticeably a cheaper instrument for laser and medical applications. Cesium-doped tungsten and pure tungsten rods were used, respectively, for the lamp cathode and anode. To seal the glassy tube, a 50-50 Fe-Ni alloy was successfully used as a medium to attach the tungsten electrodes to the borosilicate glass tube. Starting voltage of the lamp versus the gas pressure, operation voltage-current diagram at various gas pressures, and lamp spectrum in the various pressures were measured. A comparison was made with krypton arc lamp. The lamp operation was satisfactory without any crack or fracture during lightening operation. The results showed that the lamp-lightening threshold voltage depends linearly on the pressure and arc length in such a way that there is an increase in the voltage by raising these two parameters. We have also observed that by increasing the argon pressure, there is a shifting in emission spectrum from the ultraviolet to the visible region. Comparison with krypton arc lamp indicated that argon lamp needs a higher threshold lightening voltage.
Mechanism-specific effects of adenosine on ventricular tachycardia.
Lerman, Bruce B; Ip, James E; Shah, Bindi K; Thomas, George; Liu, Christopher F; Ciaccio, Edward J; Wit, Andrew L; Cheung, Jim W; Markowitz, Steven M
2014-12-01
There is no universally accepted method by which to diagnose clinical ventricular tachycardia (VT) due to cAMP-mediated triggered activity. Based on cellular and clinical data, adenosine termination of VT is thought to be consistent with a diagnosis of triggered activity. However, a major gap in evidence mitigates the validity of this proposal, namely, defining the specificity of adenosine response in well-delineated reentrant VT circuits. To this end, we systematically studied the effects of adenosine in a model of canine reentrant VT and in human reentrant VT, confirmed by 3-dimensional, pace- and substrate mapping. Adenosine (12 mg [IQR 12-24]) failed to terminate VT in 31 of 31 patients with reentrant VT due to structural heart disease, and had no effect on VT cycle length (age, 67 years [IQR 53-74]); ejection fraction, 35% [IQR 20-55]). In contrast, adenosine terminated VT in 45 of 50 (90%) patients with sustained focal right or left outflow tract tachycardia. The sensitivity of adenosine for identifying VT due to triggered activity was 90% (95% CI, 0.78-0.97) and its specificity was 100% (95% CI, 0.89-1.0). Additionally, reentrant circuits were mapped in the epicardial border zone of 4-day-old infarcts in mongrel dogs. Adenosine (300-400 μg/kg) did not terminate sustained VT or have any effect on VT cycle length. These data support the concept that adenosine's effects on ventricular myocardium are mechanism specific, such that termination of VT in response to adenosine is diagnostic of cAMP-mediated triggered activity. © 2014 Wiley Periodicals, Inc.
Fernandez, Fernando R.; Malerba, Paola; White, John A.
2015-01-01
The presence of voltage fluctuations arising from synaptic activity is a critical component in models of gain control, neuronal output gating, and spike rate coding. The degree to which individual neuronal input-output functions are modulated by voltage fluctuations, however, is not well established across different cortical areas. Additionally, the extent and mechanisms of input-output modulation through fluctuations have been explored largely in simplified models of spike generation, and with limited consideration for the role of non-linear and voltage-dependent membrane properties. To address these issues, we studied fluctuation-based modulation of input-output responses in medial entorhinal cortical (MEC) stellate cells of rats, which express strong sub-threshold non-linear membrane properties. Using in vitro recordings, dynamic clamp and modeling, we show that the modulation of input-output responses by random voltage fluctuations in stellate cells is significantly limited. In stellate cells, a voltage-dependent increase in membrane resistance at sub-threshold voltages mediated by Na+ conductance activation limits the ability of fluctuations to elicit spikes. Similarly, in exponential leaky integrate-and-fire models using a shallow voltage-dependence for the exponential term that matches stellate cell membrane properties, a low degree of fluctuation-based modulation of input-output responses can be attained. These results demonstrate that fluctuation-based modulation of input-output responses is not a universal feature of neurons and can be significantly limited by subthreshold voltage-gated conductances. PMID:25909971
Fernandez, Fernando R; Malerba, Paola; White, John A
2015-04-01
The presence of voltage fluctuations arising from synaptic activity is a critical component in models of gain control, neuronal output gating, and spike rate coding. The degree to which individual neuronal input-output functions are modulated by voltage fluctuations, however, is not well established across different cortical areas. Additionally, the extent and mechanisms of input-output modulation through fluctuations have been explored largely in simplified models of spike generation, and with limited consideration for the role of non-linear and voltage-dependent membrane properties. To address these issues, we studied fluctuation-based modulation of input-output responses in medial entorhinal cortical (MEC) stellate cells of rats, which express strong sub-threshold non-linear membrane properties. Using in vitro recordings, dynamic clamp and modeling, we show that the modulation of input-output responses by random voltage fluctuations in stellate cells is significantly limited. In stellate cells, a voltage-dependent increase in membrane resistance at sub-threshold voltages mediated by Na+ conductance activation limits the ability of fluctuations to elicit spikes. Similarly, in exponential leaky integrate-and-fire models using a shallow voltage-dependence for the exponential term that matches stellate cell membrane properties, a low degree of fluctuation-based modulation of input-output responses can be attained. These results demonstrate that fluctuation-based modulation of input-output responses is not a universal feature of neurons and can be significantly limited by subthreshold voltage-gated conductances.
Ultra-Low-Energy Sub-Threshold Circuits: Program Overview
2007-04-10
with global > 0.1 corner, but so does VUL, VIH 0 .0 5 -_ "or ni n a Global Variatlion 0.0a 0•,lN& 0.24.. 7 Mir" Output Swing Metrics " Need a... VIH . lines plot the VTCs when random local VT mismatch is ap- In Figure 1(b), a NAND gate has sufficient output swing plied to the inverter. One case...the VTC is input-dependent, all inputs are varied simultaneously to >P 1 0 SNM side of largest obtain the worst case ViH and VIL. > 0 ins0nbedsquare
Dynamics of action potential initiation in the GABAergic thalamic reticular nucleus in vivo.
Muñoz, Fabián; Fuentealba, Pablo
2012-01-01
Understanding the neural mechanisms of action potential generation is critical to establish the way neural circuits generate and coordinate activity. Accordingly, we investigated the dynamics of action potential initiation in the GABAergic thalamic reticular nucleus (TRN) using in vivo intracellular recordings in cats in order to preserve anatomically-intact axo-dendritic distributions and naturally-occurring spatiotemporal patterns of synaptic activity in this structure that regulates the thalamic relay to neocortex. We found a wide operational range of voltage thresholds for action potentials, mostly due to intrinsic voltage-gated conductances and not synaptic activity driven by network oscillations. Varying levels of synchronous synaptic inputs produced fast rates of membrane potential depolarization preceding the action potential onset that were associated with lower thresholds and increased excitability, consistent with TRN neurons performing as coincidence detectors. On the other hand the presence of action potentials preceding any given spike was associated with more depolarized thresholds. The phase-plane trajectory of the action potential showed somato-dendritic propagation, but no obvious axon initial segment component, prominent in other neuronal classes and allegedly responsible for the high onset speed. Overall, our results suggest that TRN neurons could flexibly integrate synaptic inputs to discharge action potentials over wide voltage ranges, and perform as coincidence detectors and temporal integrators, supported by a dynamic action potential threshold.
Normalization of respiratory sinus arrhythmia by factoring in tidal volume.
Kobayashi, H
1998-09-01
The amplitude of respiratory sinus arrhythmia (RSA) was measured in eight healthy young male students with special reference to the effect of tidal volume (Vt). Under simultaneously controlled respiratory frequency and Vt, the heart rate variability (HRV) of the subjects was measured. While the respiratory frequency was adjusted to either 0.25 or 0.10 Hz, the Vt was controlled at 13 different volumes for each frequency. Linear relationships between RSA amplitude and Vt were observed and close correlations were obtained for 0.25 Hz compared with 0.10 Hz. However, regression equations showed a marked variation among subjects. Furthermore, RSA amplitude was related to vital capacity. Subjects who had lower vital capacity tended to show higher RSA amplitudes at the same Vt. Therefore, the ratio (% Vt) of Vt to vital capacity is a more effective index in normalizing RSA than raw tidal volume. From these results, we have proposed a normalized RSA (RSA amplitude/% Vt) as a new index of autonomic activity that provides a constant value regardless of Vt.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erofeev, E. V., E-mail: erofeev@micran.ru; Fedin, I. V.; Kutkov, I. V.
High-electron-mobility transistors (HEMTs) based on AlGaN/GaN epitaxial heterostructures are a promising element base for the fabrication of high voltage electronic devices of the next generation. This is caused by both the high mobility of charge carriers in the transistor channel and the high electric strength of the material, which makes it possible to attain high breakdown voltages. For use in high-power switches, normally off-mode GaN transistors operating under enhancement conditions are required. To fabricate normally off GaN transistors, one most frequently uses a subgate region based on magnesium-doped p-GaN. However, optimization of the p-GaN epitaxial-layer thickness and the doping levelmore » makes it possible to attain a threshold voltage of GaN transistors close to V{sub th} = +2 V. In this study, it is shown that the use of low temperature treatment in an atomic hydrogen flow for the p-GaN-based subgate region before the deposition of gate-metallization layers makes it possible to increase the transistor threshold voltage to V{sub th} = +3.5 V. The effects under observation can be caused by the formation of a dipole layer on the p-GaN surface induced by the effect of atomic hydrogen. The heat treatment of hydrogen-treated GaN transistors in a nitrogen environment at a temperature of T = 250°C for 12 h reveals no degradation of the transistor’s electrical parameters, which can be caused by the formation of a thermally stable dipole layer at the metal/p-GaN interface as a result of hydrogenation.« less
1978-09-01
AWACS EMP Guidelines presents two different models to predict the damage pcwer of the dev-ce and the circuit damage EMP voltage ( VEMP ). Neither of...calculated as K P~ I V BD 6. The damage EMP voltage ( VEMP ) is calculated KZ EMP +IZ =D +BD VBD1F 7. The damage EMP voltage is calculated for collector
NASA Astrophysics Data System (ADS)
Ding, Xingwei; Zhang, Hao; Ding, He; Zhang, Jianhua; Huang, Chuanxin; Shi, Weimin; Li, Jun; Jiang, Xueyin; Zhang, Zhilin
2014-12-01
We successfully integrated the high-performance oxide thin film transistors with novel IZO/IGZO dual-active-layers. The results showed that dual-active-layer (IZO/IGZO) TFTs, compared with single active layer IGZO TFTs and IZO TFTs, exhibited the excellent performances; specifically, a high field effect mobility of 14.4 cm2/Vs, a suitable threshold voltage of 0.8 V, a high on/off ratio of more than 107, a steep sub-threshold swing of 0.13 V/dec, and a substantially small threshold voltage shift of 0.51 V after temperature stress from 293 K to 353 K. In order to understand the superior performance, the density-of-states (DOS) were investigated based on the temperature-dependent transfer curves. The superior electric properties were attributed to the smaller DOS and higher carrier concentration. The proposed IZO/IGZO-TFT in this paper can be used as driving devices in the next-generation flat panel displays.
Stability study of solution-processed zinc tin oxide thin-film transistors
NASA Astrophysics Data System (ADS)
Zhang, Xue; Ndabakuranye, Jean Pierre; Kim, Dong Wook; Choi, Jong Sun; Park, Jaehoon
2015-11-01
In this study, the environmental dependence of the electrical stability of solution-processed n-channel zinc tin oxide (ZTO) thin-film transistors (TFTs) is reported. Under a prolonged negative gate bias stress, a negative shift in threshold voltage occurs in atmospheric air, whereas a negligible positive shift in threshold voltage occurs under vacuum. In the positive bias-stress experiments, a positive shift in threshold voltage was invariably observed both in atmospheric air and under vacuum. In this study, the negative gate-bias-stress-induced instability in atmospheric air is explained through an internal potential in the ZTO semiconductor, which can be generated owing to the interplay between H2O molecules and majority carrier electrons at the surface of the ZTO film. The positive bias-stress-induced instability is ascribed to electron-trapping phenomenon in and around the TFT channel region, which can be further augmented in the presence of air O2 molecules. These results suggest that the interaction between majority carriers and air molecules will have crucial implications for a reliable operation of solution-processed ZTO TFTs. [Figure not available: see fulltext.
Performance analysis and simulation of vertical gallium nitride nanowire transistors
NASA Astrophysics Data System (ADS)
Witzigmann, Bernd; Yu, Feng; Frank, Kristian; Strempel, Klaas; Fatahilah, Muhammad Fahlesa; Schumacher, Hans Werner; Wasisto, Hutomo Suryo; Römer, Friedhard; Waag, Andreas
2018-06-01
Gallium nitride (GaN) nanowire transistors are analyzed using hydrodynamic simulation. Both p-body and n-body devices are compared in terms of threshold voltage, saturation behavior and transconductance. The calculations are calibrated using experimental data. The threshold voltage can be tuned from enhancement to depletion mode with wire doping. Surface states cause a shift of threshold voltage and saturation current. The saturation current depends on the gate design, with a composite gate acting as field plate in the p-body device. He joined Bell Laboratories, Murray Hill, NJ, as a Technical Staff Member. In October 2001, he joined the Optical Access and Transport Division, Agere Systems, Alhambra, CA. In 2004, he was appointed an Assistant Professor at ETH Zurich,. Since 2008, at the University of Kassel, Kassel, Germany, and he has been a Professor the Head of the Computational Electronics and Photonics Group, and co-director of CINSaT since 2010. His research interests include computational optoelectronics, process and device design of semiconductor photonic devices, microwave components, and electromagnetics modeling for nanophotonics. Dr. Witzigmann is a senior member of the SPIE and IEEE.
Circuit design advances for ultra-low power sensing platforms
NASA Astrophysics Data System (ADS)
Wieckowski, Michael; Dreslinski, Ronald G.; Mudge, Trevor; Blaauw, David; Sylvester, Dennis
2010-04-01
This paper explores the recent advances in circuit structures and design methodologies that have enabled ultra-low power sensing platforms and opened up a host of new applications. Central to this theme is the development of Near Threshold Computing (NTC) as a viable design space for low power sensing platforms. In this paradigm, the system's supply voltage is approximately equal to the threshold voltage of its transistors. Operating in this "near-threshold" region provides much of the energy savings previously demonstrated for subthreshold operation while offering more favorable performance and variability characteristics. This makes NTC applicable to a broad range of power-constrained computing segments including energy constrained sensing platforms. This paper explores the barriers to the adoption of NTC and describes current work aimed at overcoming these obstacles in the circuit design space.
Thacker, Louis H.
1990-01-01
An ionizing radiation detector is provided which is based on the principle of analog electronic integration of radiation sensor currents in the sub-pico to nano ampere range between fixed voltage switching thresholds with automatic voltage reversal each time the appropriate threshold is reached. The thresholds are provided by a first NAND gate Schmitt trigger which is coupled with a second NAND gate Schmitt trigger operating in an alternate switching state from the first gate to turn either a visible or audible indicating device on and off in response to the gate switching rate which is indicative of the level of radiation being sensed. The detector can be configured as a small, personal radiation dosimeter which is simple to operate and responsive over a dynamic range of at least 0.01 to 1000 R/hr.
Arrhythmogenic Mechanisms in a Mouse Model of Catecholaminergic Polymorphic Ventricular Tachycardia
Cerrone, Marina; Noujaim, Sami F.; Tolkacheva, Elena G.; Talkachou, Arkadzi; O’Connell, Ryan; Berenfeld, Omer; Anumonwo, Justus; Pandit, Sandeep V.; Vikstrom, Karen; Napolitano, Carlo; Priori, Silvia G.; Jalife, José
2008-01-01
Catecholaminergic polymorphic ventricular tachycardia (VT) is a lethal familial disease characterized by bidirectional VT, polymorphic VT, and ventricular fibrillation. Catecholaminergic polymorphic VT is caused by enhanced Ca2+ release through defective ryanodine receptor (RyR2) channels. We used epicardial and endocardial optical mapping, chemical subendocardial ablation with Lugol’s solution, and patch clamping in a knockin (RyR2/RyR2R4496C) mouse model to investigate the arrhythmogenic mechanisms in catecholaminergic polymorphic VT. In isolated hearts, spontaneous ventricular arrhythmias occurred in 54% of 13 RyR2/RyR2R4496C and in 9% of 11 wild-type (P=0.03) littermates perfused with Ca2+ and isoproterenol; 66% of 12 RyR2/RyR2R4496C and 20% of 10 wild-type hearts perfused with caffeine and epinephrine showed arrhythmias (P=0.04). Epicardial mapping showed that monomorphic VT, bidirectional VT, and polymorphic VT manifested as concentric epicardial breakthrough patterns, suggesting a focal origin in the His–Purkinje networks of either or both ventricles. Monomorphic VT was clearly unifocal, whereas bidirectional VT was bifocal. Polymorphic VT was initially multifocal but eventually became reentrant and degenerated into ventricular fibrillation. Endocardial mapping confirmed the Purkinje fiber origin of the focal arrhythmias. Chemical ablation of the right ventricular endocardial cavity with Lugol’s solution induced complete right bundle branch block and converted the bidirectional VT into monomorphic VT in 4 anesthetized RyR2/RyR2R4496C mice. Under current clamp, single Purkinje cells from RyR2/RyR2R4496C mouse hearts generated delayed afterdepolarization–induced triggered activity at lower frequencies and level of adrenergic stimulation than wild-type. Overall, the data demonstrate that the His–Purkinje system is an important source of focal arrhythmias in catecholaminergic polymorphic VT. PMID:17872467
Stein-Merlob, Ashley F.; Kessinger, Chase W.; Erdem, S. Sibel; Zelada, Henry; Hilderbrand, Scott A.; Lin, Charles P.; Tearney, Guillermo J.; Jaff, Michael R.; Reed, Guy L.; Henke, Peter K.; McCarthy, Jason R.; Jaffer, Farouc A.
2015-01-01
Fibrinolytic therapy of venous thromboembolism (VTE) is increasingly utilized, yet limited knowledge is available regarding in vivo mechanisms that govern fibrinolytic efficacy. In particular, it is unknown how age-dependent thrombus organization limits direct blood contact with fibrin, the target of blood-based fibrinolytic agents. Utilizing high-resolution in vivo optical molecular imaging with FTP11, a near-infrared fluorescence (NIRF) fibrin-specific reporter, here we investigated the in vivo interrelationships of blood accessibility to fibrin, thrombus age, thrombus neoendothelialization, and fibrinolysis in murine venous thrombosis (VT). In both stasis VT and non-stasis VT, NIRF microscopy showed that FTP11 fibrin binding was thrombus age-dependent. FTP11 localized to the luminal surface of early-stage VT, but only minimally to subacute VT (p<0.001). Transmission electron microscopy of early stage VT revealed direct blood cell contact with luminal fibrin-rich surfaces. In contrast, subacute VT exhibited an encasing CD31+ neoendothelial layer that limited blood cell contact with thrombus fibrin in both VT models. Next we developed a theranostic strategy to predict fibrinolytic efficacy based on the in vivo fibrin accessibility to blood NIRF signal. Mice with variably aged VT underwent FTP11 injection and intravital microscopy (IVM), followed by tissue plasminogen activator infusion to induce VT fibrinolysis. Fibrin molecular IVM revealed that early stage VT, but not subacute VT, bound FTP11 (p<0.05), and experienced higher rates of fibrinolysis and total fibrinolysis (p<0.05 vs. subacute VT). Before fibrinolysis, the baseline FTP11 NIRF signal predicted the net fibrinolysis at 60 minutes (p<0.001). Taken together, these data provide novel insights into the temporal evolution of VT and its susceptibility to therapeutic fibrinolysis. Fibrin molecular imaging may provide a theranostic strategy to identify venous thrombi amenable to fibrinolytic therapies. PMID:26516370
Apparatus for Controlling Low Power Voltages in Space Based Processing Systems
NASA Technical Reports Server (NTRS)
Petrick, David J. (Inventor)
2017-01-01
A low power voltage control circuit for use in space missions includes a switching device coupled between an input voltage and an output voltage. The switching device includes a control input coupled to an enable signal, wherein the control input is configured to selectively turn the output voltage on or off based at least in part on the enable signal. A current monitoring circuit is coupled to the output voltage and configured to produce a trip signal, wherein the trip signal is active when a load current flowing through the switching device is determined to exceed a predetermined threshold and is inactive otherwise. The power voltage control circuit is constructed of space qualified components.
Highly Uniform Carbon Nanotube Field-Effect Transistors and Medium Scale Integrated Circuits.
Chen, Bingyan; Zhang, Panpan; Ding, Li; Han, Jie; Qiu, Song; Li, Qingwen; Zhang, Zhiyong; Peng, Lian-Mao
2016-08-10
Top-gated p-type field-effect transistors (FETs) have been fabricated in batch based on carbon nanotube (CNT) network thin films prepared from CNT solution and present high yield and highly uniform performance with small threshold voltage distribution with standard deviation of 34 mV. According to the property of FETs, various logical and arithmetical gates, shifters, and d-latch circuits were designed and demonstrated with rail-to-rail output. In particular, a 4-bit adder consisting of 140 p-type CNT FETs was demonstrated with higher packing density and lower supply voltage than other published integrated circuits based on CNT films, which indicates that CNT based integrated circuits can reach to medium scale. In addition, a 2-bit multiplier has been realized for the first time. Benefitted from the high uniformity and suitable threshold voltage of CNT FETs, all of the fabricated circuits based on CNT FETs can be driven by a single voltage as small as 2 V.
Anatomy of filamentary threshold switching in amorphous niobium oxide.
Li, Shuai; Liu, Xinjun; Nandi, Sanjoy Kumar; Elliman, Robert Glen
2018-06-25
The threshold switching behaviour of Pt/NbOx/TiN devices is investigated as a function device area and NbOx film thickness and shown to reveal important insight into the structure of the self-assembled switching region. The devices exhibit combined selector-memory (1S1R) behavior after an initial voltage-controlled forming process, but exhibit symmetric threshold switching when the RESET and SET currents are kept below a critical value. In this mode, the threshold and hold voltages are independent of the device area and film thickness but the threshold current (power), while independent of device area, decreases with increasing film thickness. These results are shown to be consistent with a structure in which the threshold switching volume is confined, both laterally and vertically, to the region between the residual memory filament and the TiN electrode, and where the memory filament has a core-shell structure comprising a metallic core and a semiconducting shell. The veracity of this structure is demonstrated by comparing experimental results with the predictions of a simple circuit model, and more detailed finite element simulations. These results provide further insight into the structure and operation of NbOx threshold switching devices that have application in emerging memory and neuromorphic computing fields. © 2018 IOP Publishing Ltd.
Avoidance of Timeout from Response-Independent Food: Effects of Delivery Rate and Quality
ERIC Educational Resources Information Center
Richardson, Joseph V.; Baron, Alan
2008-01-01
In three experiments, a rat's lever presses could postpone timeouts from food pellets delivered on response-independent schedules. In Experiment 1, the pellets were delivered at variable-time (VT) rates ranging from VT 0.5 to VT 8 min. Experiment 2 replicated the VT 1 min and VT 8 min conditions of Experiment 1 with new subjects. Finally, subjects…
Influence of humic acid on adsorption of Hg(II) by vermiculite.
do Nascimento, Fernando Henrique; Masini, Jorge Cesar
2014-10-01
Geochemical mobility of Hg(II) species is strongly affected by the interactions of these compounds with naturally occurring adsorbents such as humic acids, clay minerals, oxides, etc. Interactions among these sorbents affect their affinity for Hg(II) and a full understanding of these processes is still lacking. The present work describes the influence of a humic acid (HA) sample on the adsorption of Hg(II) by vermiculite (VT). Adsorption isotherms were constructed to evaluate the affinity of Hg(II) by VT, HA, VT modified with humic acid (VT-HA), and VT-HA in presence of soluble humic acid (VT-HA + HA). All experiments were made at pH 6.0 ± 0.1 in 0.02 M NaNO3 and 25.0 ± 0.5 °C for initial Hg(II) concentrations from 1.0 to 100 μM. Determinations of Hg(II) were made by square wave voltammetry automated by sequential injection analysis, an approach that enables the determination of the free plus labile fractions of Hg(II) in HA suspensions without the need for laborious separation steps. The adsorption isotherms were fitted to Langmuir and Freundlich equations, showing that HA was the material with the higher adsorption capacity (537 ± 30 μmol g(-1)) in comparison with VT and VT-HA (44 ± 3 and 51 ± 11 μmol g(-1), respectively). Adsorption order was HA > VT-HA + HA > VT = VT-HA. At pH 6.0 the interaction of HA with VT is weak and only 14% of C initially added to the suspension was effectively retained by the mineral. Desorption of Hg(II) in acidic medium (0.05 M HCl) was higher in binary (VT-HA) and ternary (VT-HA + HA) systems in comparison with that of VT and HA alone, suggesting that interactions between VT and HA are facilitated in acidic medium, weakening the binding to Hg(II). Copyright © 2014 Elsevier Ltd. All rights reserved.
The association of statin therapy with the risk of recurrent venous thrombosis.
Smith, N L; Harrington, L B; Blondon, M; Wiggins, K L; Floyd, J S; Sitlani, C M; McKnight, B; Larson, E B; Rosendaal, F R; Heckbert, S R; Psaty, B M
2016-07-01
Essentials A lowered risk of recurrent venous thrombosis (VT) with statin treatment is controversial. Among observational inception cohort of 2,798 adults with incident VT, 457 had recurrent VT. Time-to-event models with time-varying statin use and adjustment for potential confounders was used for analysis. Compared to nonuse, current statin use was associated with 26% lower risk of recurrent VT. Click to hear Prof. Büller's perspective on Anticoagulant Therapy in the Treatment of Venous Thromboembolism Background Meta-analyses of randomized controlled trials suggest that treatment with hydroxymethylglutaryl-coenzyme A reductase inhibitors (statins) lowers the risk of incident venous thrombosis (VT), particularly among those without prevalent clinical cardiovascular disease (CVD). Whether this is true for the prevention of recurrent VT is debated. We used an observational inception cohort to estimate the association of current statin use with the risk of recurrent VT. Methods and Results The study setting was a large healthcare organization with detailed medical record and pharmacy information at cohort entry and throughout follow-up. We followed 2798 subjects 18-89 years of age who experienced a validated incident VT between January 1, 2002, and December 31, 2010, for a first recurrent VT, validated by medical record review. During follow-up, 457 (16%) developed a first recurrent VT. In time-to-event models incorporating time-varying statin use and adjusting for potential confounders, current statin use was associated with a 26% lower risk of recurrent VT: hazard ratio 0.74, 95% confidence interval 0.59-0.94. Among cohort members free of CVD (n = 2134), current statin use was also associated with a lower risk (38%) of recurrent VT: hazard ratio 0.62, 95% confidence interval 0.45-0.85. We found similar results when restricting to new users of statins and in subgroups of different statin types and doses. Conclusions In a population-based cohort of subjects who had experienced an incident VT, statin use, compared with nonuse, was associated with a clinically relevant lower risk of recurrent VT. These findings suggest a potential secondary benefit of statins among patients who have experienced an incident VT. © 2016 International Society on Thrombosis and Haemostasis.
Diagnosis and ablation of multiform fascicular tachycardia.
Sung, Raphael K; Kim, Albert M; Tseng, Zian H; Han, Frederick; Inada, Keiichi; Tedrow, Usha B; Viswanathan, Mohan N; Badhwar, Nitish; Varosy, Paul D; Tanel, Ronn; Olgin, Jeffrey E; Stephenson, William G; Scheinman, Melvin
2013-03-01
Fascicular tachycardia (FT) is an uncommon cause of monomorphic sustained ventricular tachycardia (VT). We describe 6 cases of FT with multiform QRS morphologies. Six of 823 consecutive VT cases were retrospectively analyzed and found attributable to FT with multiform QRS patterns, with 3 cases exhibiting narrow QRS VT as well. All underwent electrophysiology study including fascicular potential mapping, entrainment pacing, and electroanatomic mapping. The first 3 cases describe similar multiform VT patterns with successful ablation in the upper mid septum. Initially, a right bundle branch block (RBBB) VT with superior axis was induced. Radiofrequency catheter ablation (RFCA) targeting the left posterior fascicle (LPF) resulted in a second VT with RBBB inferior axis. RFCA in the upper septum just apical to the LBB potential abolished VT in all cases. Cases 4 and 5 showed RBBB VT with alternating fascicular block compatible with upper septal dependent VT, resulting in bundle branch reentrant VT (BBRT) after ablation of LPF and left anterior fascicle (LAF). Finally, Cases 5 and 6 demonstrated spontaneous shift in QRS morphology during VT, implicating participation of a third fascicle. In Case 6, successful ablation was achieved over the proximal LAF, likely representing insertion of the auxiliary fascicle near the proximal LAF. Multiform FTs show a reentrant mechanism using multiple fascicular branches. We hypothesize that retrograde conduction over the septal fascicle produces alternate fascicular patterns as well as narrow VT forms. Ablation of the respective fascicle was successful in abolishing FT but does not preclude development of BBRT unless septal fascicle is targeted and ablated. © 2012 Wiley Periodicals, Inc.
Do, Duc H; Bradfield, Jason; Ajijola, Olujimi A; Vaseghi, Marmar; Le, John; Rahman, Siamak; Mahajan, Aman; Nogami, Akihiko; Boyle, Noel G; Shivkumar, Kalyanam
2017-10-27
Novel therapies aimed at modulating the autonomic nervous system, including thoracic epidural anesthesia (TEA), have been shown in small case series to be beneficial in treating medically refractory ventricular tachycardia (VT) storm. However, it is not clear when these options should be considered. We reviewed a multicenter experience with TEA in the management of VT storm to determine its optimal therapeutic use. Data for 11 patients in whom TEA was instituted for VT storm between July 2005 and March 2016 were reviewed to determine the clinical characteristics, outcomes, and role in management. The clinical presentation was incessant VT in 7 (64%), with polymorphic VT in 3 (27%) and monomorphic VT in 8 (73%). The underlying conditions were nonischemic cardiomyopathy in 5 (45%), ischemic cardiomyopathy in 3 (27%), and hypertrophic cardiomyopathy, Brugada syndrome, and cardiac lipoma in 1 (9%) each. Five (45%) had a complete and 1 (9%) had a partial response to TEA; 4 of the complete responders had incessant VT. All 4 patients with a documented response to deep sedation demonstrated a complete response to TEA. More than half of the patients with VT storm in our series responded to TEA. TEA may be effective and should be considered as a therapeutic option in patients with VT storm, especially incessant VT, who are refractory to initial management. Improvement in VT burden with deep sedation may suggest that sympathoexcitation plays a key role in perpetuating VT and predict a positive response to TEA. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Gopinathannair, Rakesh; Chaudhary, Ashok K; Xing, Dezhi; Ely, Debra; Zheng, Wei; Martins, James B
2009-11-01
Ischemic focal ventricular tachycardia (VT) occurs in animals and humans. Angiotensin-converting enzyme inhibitors and receptor blockers reduce sudden death in patients with ischemic heart disease. In our dog model of coronary artery occlusion (CAO), we tested the hypothesis that angiotensin II (AGII) will selectively promote focal VT and that the specific AT(2) blocker PD-123319 (PD), or AT(1) blocker losartan, will affect this VT. Anesthetized dogs (n = 90) underwent CAO, followed by three-dimensional activation mapping of inducible VT. Dogs without VT in 1-3 h after CAO received AGII, and those with VT received either PD or losartan. Focal endocardium excised from ischemic sites was studied in vitro with standard microelectrode. Of 33 dogs with no inducible VT, AGII infusion resulted in sustained VT of only focal Purkinje origin in 13 (39%) compared with 0 of 20 dogs with saline. Of 26 dogs with inducible VT at baseline, given PD, reinduction was blocked in 8 of 10 (P < 0.05) focal VT, but only 1 of 15 with reentry. In contrast, of 11 dogs given losartan, reinduction of either mechanism was not blocked. In vitro triggered activity in Purkinje was blocked by PD in 13 of 19 (P < 0.05), but not by losartan in 8. Also, triggered activity was promoted by AGII, losartan, or the combination in 9 of 12 tissues. AGII promotes only focal, mainly Purkinje ischemic VT. PD, but not losartan, preferentially blocked focal VT, which is likely due to triggered activity due to delayed afterdepolarizations in Purkinje.
Herraiz, Sonia; Novella-Maestre, Edurne; Rodríguez, Beatriz; Díaz, César; Sánchez-Serrano, María; Mirabet, Vicente; Pellicer, Antonio
2014-03-01
To compare slow freezing (SF) with four vitrification techniques (VT) for cryopreservation of ovarian tissue (OT) and to evaluate the best protocol for human OT in a xenograft model. Experimental study. University hospital. Patients undergoing fertility preservation. Ovariectomized nude mice. Cryopreservation of bovine OT after SF and four VTs (VT1, VT2, VT3, and VT4) by combining two cryoprotectant vitrification solutions (VS1 and VS2) and two devices (metallic grid and ethyl vinyl acetate bag), after which the cryopreservation of human OT by SF and VT1 and xenograft into nude mice. Follicular densities, proliferation, vascularization, fibrosis, apoptosis, tissue viability. The in vitro study in bovine OT showed a lower percentage of quiescent follicles in the SF group but not in the vitrification groups (VT1-VT4). Apoptosis increased and cell proliferation decreased in all the experimental groups except VT1 (20% ethylene glycol, 20% dimethyl sulfoxide, 0.5 M sucrose, and 20% synthetic serum substitute in HEPES-buffered M199 culture media with Cryotissue metallic grids). Tissue viability was diminished in VT3, and the SF-xenografted human samples showed reduced primordial and secondary densities and unbalanced follicular populations when compared with fresh and VT1 tissue. VT1 offers similar conditions to fresh tissue for follicular density, proliferation, viability, and cell death and preserves a larger population of quiescent follicles than SF after transplantation, thus ensuring the maintenance of graft potential fertility. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Zawieja, Emilia E.; Podgórski, Tomasz; Łoniewski, Igor; Zawieja, Bogna E.
2018-01-01
Background Sodium bicarbonate (SB) has been proposed as an ergogenic aid, as it improves high-intensity and resistance exercise performance. However, no studies have yet investigated SB application in CrossFit. This study examined the effects of chronic, progressive-dose SB ingestion on CrossFit-like performance and aerobic capacity. Methods In a randomized, double-blind, cross-over trial, 21 CrossFit-trained participants were randomly allocated to 2 groups and underwent 2 trials separated by a 14-day washout period. Participants ingested either up to 150 mg∙kg-1 of SB in a progressive-dose regimen or placebo for 10 days. Before and after each trial, Fight Gone Bad (FGB) and incremental cycling (ICT) tests were performed. In order to examine biochemical responses, blood samples were obtained prior to and 3 min after completing each exercise test. Results No gastrointestinal (GI) side effects were reported during the entire protocol. The overall FGB performance improved under SB by ~6.1% (p<0.001) and it was ~3.1% higher compared to post placebo (PLApost) (p = 0.040). The number of repetitions completed in each round also improved under SB (mean from baseline: +5.8% to +6.4%). Moreover, in ICT, the time to ventilatory threshold (VT) (~8:25 min SBpost vs. ~8:00 min PLApost, p = 0.020), workload at VT (~218 W SBpost vs. ~208 W PLApost, p = 0.037) and heart rate at VT (~165 bpm SBpost vs. ~161 bpm PLApost, p = 0.030) showed higher SBpost than PLApost. Furthermore, the maximum carbon dioxide production increased under SB by ~4.8% (from ~3604 mL∙min-1 to ~3776 mL∙min-1, p = 0.049). Pyruvate concentration and creatine kinase activity before ICT showed higher SBpost than PLApost (~0.32 mmol∙L-1 vs. ~0.26 mmol∙L-1, p = 0.001; ~275 U∙L-1 vs. ~250 U∙L-1, p = 0.010, respectively). However, the small sample size limits the wide-application of our results. Conclusions Progressive-dose SB ingestion regimen eliminated GI side effects and improved CrossFit-like performance, as well as delayed ventilatory threshold occurrence. PMID:29771966
Selvam, R; Jurkevich, A; Kang, S W; Mikhailova, M V; Cornett, L E; Kuenzel, W J
2013-01-01
The neurohormone arginine vasotocin (AVT) in non mammalian vertebrates is homologous to arginine vasopressin (AVP) in mammals. Its actions are mediated via G protein-coupled receptors that belong to the vasotocin/mesotocin family. Because of the known regulatory effects of nonapeptide hormones on anterior pituitary functions, receptor subtypes in that family have been proposed to be located in anterior pituitary cells. Recently, an avian vasotocin receptor subtype designated VT4R has been cloned, which shares 69% sequence homology with a human vasopressin receptor, the V1aR. In the present study, a polyclonal antibody to the VT4R was developed and validated to confirm its specificity to the VT4R. The antibody was used to test the hypothesis that the VT4R is present in the avian anterior pituitary and is specifically associated with certain cell types, where its expression is modulated by acute stress. Western blotting of membrane protein extracts from pituitary tissue, the use of HeLa cells transfected with the VT4R and peptide competition assays all confirmed the specificity of the antibody to the VT4R. Dual-labelling immunofluorescence microscopy was utilised to identify pituitary cell types that contained immunoreactive VT4R. The receptor was found to be widely distributed throughout the cephalic lobe but not in the caudal lobe of the anterior pituitary. Immunoreactive VT4R was associated with corticotrophs. Approximately 89% of immunolabelled corticotrophs were shown to contain the VT4R. The immunoreactive VT4R was not found in gonadotrophs, somatotrophs or lactotrophs. To determine a possible functional role of the VT4R and previously characterised VT2R, gene expression levels in the anterior pituitary were determined after acute immobilisation stress by quantitative reverse transcriptase-polymerase chain reaction. The results showed a significant increase in plasma corticosterone levels (three- to four-fold), a significant reduction of VT4R mRNA and an increase of VT2R mRNA (P < 0.05) in acutely immobilised chicks compared to controls. The data suggest a role of the VT4R in the avian stress response. © 2012 British Society for Neuroendocrinology.
You, J S; Park, S; Chung, S P; Park, J W
2009-03-01
A needle thoracocentesis should be performed with maximal safety and optimal efficacy in mind. Mobile video telephony (VT) could be used to facilitate instructions for the accurate performance of needle thoracocentesis in an emergency setting. This new communication method will increase the accuracy of identifying the relevant anatomical site during the decompression technique. A prospective randomised manikin study was performed to investigate the effectiveness of using VT as a method of instruction for the identification of anatomical landmarks during the performance of needle thoracocentesis. The overall success rate was significantly higher in the VT group which performed needle thoracocentesis under the guidance of VT than in the non-VT group who performed the procedure without VT-aided instruction. The instrument difficulty score and procedure satisfaction score were significantly lower in the VT group than in the non-VT group. Identification of the correct anatomical landmark for needle thoracocentesis can be performed with instructions provided via VT because a dispatcher can monitor every step and provide correct instructions. This new technology will improve critical care medicine.
Photocurrent Suppression of Transparent Organic Thin Film Transistors
NASA Astrophysics Data System (ADS)
Chuang, Chiao-Shun; Tsai, Shu-Ting; Lin, Yung-Sheng; Chen, Fang-Chung; Shieh, Hang-Ping D.
2007-12-01
Organic thin-film transistors (OTFTs) with high transmittance and low photosensitivity have been demonstrated. By using titanium dioxide nanoparticles as the additives in the polymer gate insulators, the level of device photoresponse has been reduced. The device shows simultaneously a high transparence and a minimal threshold voltage shift under white light illumination. It is inferred that the localized energy levels deep in the energy gap of pentacene behave as the recombination centers, enhancing substantially the recombination process in the conducting channel of the OTFTs. Therefore, the electron trapping is relieved and the shift of threshold voltage is reduced upon illumination.
Kremers, M S; Black, W H; Lange, R; Wells, P J; Solo, M
1990-11-01
Electrocardiographic signal-averaging during sinus rhythm (61 to 99 beats/min) and atrial pacing (100 to 171 beats/min) were performed to determine the effect of heart rate on late potentials in 15 patients without (group 1) and 7 patients with (group 2) inducible sustained ventricular tachycardia (VT). In sinus rhythm (79 +/- 12 vs 77 +/- 12 beats/min, difference not significant), the duration of the low-amplitude signal less than 40 microV was longer in group 2 than group 1 (43 +/- 21 vs 26 +/- 8 ms, p = 0.034) and more patients had late potentials (57 vs 7%, p = 0.021), but QRS duration (121 +/- 32 vs 98 +/- 19 ms) and terminal voltage (33 +/- 33 vs 50 +/- 26 ms) were not significantly different. With atrial pacing in group 1 (128 +/- 16 beats/min), 3 patients developed a simultaneous decrease in terminal voltage and an increase in terminal QRS duration consistent with a late potential, but mean total and terminal durations were unchanged. Terminal voltage increased (50 +/- 26 to 59 +/- 40) but not significantly. With atrial pacing in group 2 (119 +/- 12 beats/min) all patients either had a late potential or developed a simultaneous decrease in terminal voltage and an increase in terminal QRS duration (p = 0.001 vs group 1). Root mean square (p = 0.001 vs group 1). Root mean square voltage decreased (33 +/- 23 to 22 +/- 23) and became significantly different from group 1 (p = 0.017). Mean QRS duration, root mean square terminal voltage and low-amplitude terminal QRS duration, however, were unchanged.(ABSTRACT TRUNCATED AT 250 WORDS)
NASA Astrophysics Data System (ADS)
Chen, R. M.; Diggins, Z. J.; Mahatme, N. N.; Wang, L.; Zhang, E. X.; Chen, Y. P.; Zhang, H.; Liu, Y. N.; Narasimham, B.; Witulski, A. F.; Bhuva, B. L.; Fleetwood, D. M.
2017-08-01
The single-event sensitivity of bulk 40-nm sequential circuits is investigated as a function of temperature and supply voltage. An overall increase in SEU cross section versus temperature is observed at relatively high supply voltages. However, at low supply voltages, there is a threshold temperature beyond which the SEU cross section decreases with further increases in temperature. Single-event transient induced errors in flip-flops also increase versus temperature at relatively high supply voltages and are more sensitive to temperature variation than those caused by single-event upsets.
CNFET-based voltage rectifier circuit for biomedical implantable applications
NASA Astrophysics Data System (ADS)
Tu, Yonggen; Qian, Libo; Xia, Yinshui
2017-02-01
Carbon nanotube field effect transistor (CNFET) shows lower threshold voltage and smaller leakage current in comparison to its CMOS counterpart. In this paper, two kinds of CNFET-based rectifiers, full-wave rectifiers and voltage doubler rectifiers are presented for biomedical implantable applications. Based on the standard 32 nm CNFET model, the electrical performance of CNFET rectifiers is analyzed and compared. Simulation results show the voltage conversion efficiency (VCE) and power conversion efficiency (PCE) achieve 70.82% and 72.49% for CNFET full-wave rectifiers and 56.60% and 61.17% for CNFET voltage double rectifiers at typical 1.0 V input voltage excitation, which are higher than that of CMOS design. Moreover, considering the controllable property of CNFET threshold voltage, the effect of various design parameters on the electrical performance is investigated. It is observed that the VCE and PCE of CNFET rectifier increase with increasing CNT diameter and number of tubes. The proposed results would provide some guidelines for design and optimization of CNFET-based rectifier circuits. Project supported by the National Natural Science Foundation of China (Nos. 61131001, 61404077, 61571248), the Science and Technology Fund of Zhejiang Province (No. 2015C31090), the Natural Science Foundation of Ningbo (No. 2014A610147), State Key Laboratory of ASIC & System (No. 2015KF006) and the K. C. Wong Magna Fund in Ningbo University.
Evaluation of anthropometric parameters and physical fitness in elderly Japanese.
Miyatake, Nobuyuki; Miyachi, Motohiko; Tabata, Izumi; Numata, Takeyuki
2012-01-01
We evaluated anthropometric parameters and physical fitness in elderly Japanese. A total of 2,106 elderly Japanese (749 men and 1,357 women), aged 60-79 years, were enrolled in a cross-sectional investigation study. Anthropometric parameters and physical fitness, i.e., muscle strength and flexibility, were measured. Of the 2,106 subjects, 569 subjects (302 men and 267 women) were further evaluated for aerobic exercise level, using the ventilatory threshold (VT). Muscle strength in subjects in their 70s was significantly lower than that in subjects in their 60s in both sexes. Two hundred and twenty-nine men (30.6%) and 540 women (39.8%) were taking no medications. In men, anthropometric parameters were significantly lower and muscle strength, flexibility, and work rate at VT were significantly higher in subjects without medications than these values in subjects with medications. In women, body weight, body mass index (BMI), and abdominal circumference were significantly lower, and muscle strength was significantly higher in subjects without medications than these values in subjects with medications. This mean value may provide a useful database for evaluating anthropometric parameters and physical fitness in elderly Japanese subjects.
Koplan, Bruce A; Gilligan, David M; Nguyen, Luc S; Lau, Theodore K; Thackeray, Lisa M; Berg, Kellie Chase
2008-11-01
An automatic capture (AC) algorithm adjusts ventricular pacing output to capture the ventricle while optimizing output to 0.5 V above threshold. AC maintains this output and confirms capture on a beat-to-beat basis in bipolar and unipolar pacing and sensing. To assess the AC algorithm and its impact on device longevity. Patients implanted with a pacemaker were randomized 1:1 to have the AC feature on or off for 12 months. Two threshold tests were conducted at each visit- automatic threshold and manual threshold. Average ventricular voltage output and projected device longevity were compared between AC on and off using nonparametric tests. Nine hundred ten patients were enrolled and underwent device implantation. Average ventricular voltage output was 1.6 V for the AC on arm (n = 444) and 3.1 V for the AC off arm (n = 446) (P < 0.001). Projected device longevity was 10.3 years for AC on and 8.9 years for AC off (P < 0.0001), or a 16% increase in longevity for AC on. The proportion of patients in whom there was a difference between automatic threshold and manual threshold of
Skucas, Kestutis; Pokvytyte, Vaida
2017-04-01
The aim of this paper was to investigate the effect of short-term period, moderate intensity and high volume endurance training on physiological variables in elite wheelchair basketball players. Eight wheelchair basketball players were examined. The subjects participated in a two-week intervention program of mainly two training types: wheelchair basketball and wheelchair driving endurance training. The subjects performed the continuously increasing cycling exercise (CCE) at the constant 60 rpm arm cranking speed at the beginning of the program and after two weeks of the program. The initial workload was 20 W, then the workload was increased by 2 W every 5 seconds until fatigue. The post training of the wheelchair basketball group in the study showed a significant improvement in the peak oxygen uptake (VO2peak) and the peak power output (POpeak). VO2peak increased by 9% from 2.32±0.16 L/min to 2.53±0.2 L/min (P<0.05). POpeak increased by 28% from 141.75±14.23 W, to 181.63±26.3 W (P<0.05). The pre-training and post training test power output (PO [w]), relative power output (PO [w/kg]) increased significantly in all zones of energy production. In conclusion, this study indicated that the wheelchair basketball squad had relatively high levels of aerobic fitness prior to participating in the endurance training program. Nevertheless, the high-volume, moderate-intensity, short-term training program, which evolved over the two-weeks period, resulted in the improvement of the athlete's aerobic endurance. The ventilatory threshold (VT) and the second ventilatory threshold (VT2) are good markers for aerobic capacity of wheelchair athletes.
Gómez-Molina, Josué; Ogueta-Alday, Ana; Camara, Jesus; Stickley, Christopher; García-López, Juan
2018-03-01
Concurrent plyometric and running training has the potential to improve running economy (RE) and performance through increasing muscle strength and power, but the possible effect on spatiotemporal parameters of running has not been studied yet. The aim of this study was to compare the effect of 8 weeks of concurrent plyometric and running training on spatiotemporal parameters and physiological variables of novice runners. Twenty-five male participants were randomly assigned into two training groups; running group (RG) (n = 11) and running + plyometric group (RPG) (n = 14). Both groups performed 8 weeks of running training programme, and only the RPG performed a concurrent plyometric training programme (two sessions per week). Anthropometric, physiological (VO 2max , heart rate and RE) and spatiotemporal variables (contact and flight times, step rate and length) were registered before and after the intervention. In comparison to RG, the RPG reduced step rate and increased flight times at the same running speeds (P < .05) while contact times remained constant. Significant increases in pre- and post-training (P < .05) were found in RPG for squat jump and 5 bound test, while RG remained unchanged. Peak speed, ventilatory threshold (VT) speed and respiratory compensation threshold (RCT) speed increased (P < .05) for both groups, although peak speed and VO 2max increased more in the RPG than in the RG. In conclusion, concurrent plyometric and running training entails a reduction in step rate, as well as increases in VT speed, RCT speed, peak speed and VO 2max . Athletes could benefit from plyometric training in order to improve their strength, which would contribute to them attaining higher running speeds.
GaN HEMTs with p-GaN gate: field- and time-dependent degradation
NASA Astrophysics Data System (ADS)
Meneghesso, G.; Meneghini, M.; Rossetto, I.; Canato, E.; Bartholomeus, J.; De Santi, C.; Trivellin, N.; Zanoni, E.
2017-02-01
GaN-HEMTs with p-GaN gate have recently demonstrated to be excellent normally-off devices for application in power conversion systems, thanks to the high and robust threshold voltage (VTH>1 V), the high breakdown voltage, and the low dynamic Ron increase. For this reason, studying the stability and reliability of these devices under high stress conditions is of high importance. This paper reports on our most recent results on the field- and time-dependent degradation of GaN-HEMTs with p-GaN gate submitted to stress with positive gate bias. Based on combined step-stress experiments, constant voltage stress and electroluminescence testing we demonstrated that: (i) when submitted to high/positive gate stress, the transistors may show a negative threshold voltage shift, that is ascribed to the injection of holes from the gate metal towards the p-GaN/AlGaN interface; (ii) in a step-stress experiment, the analyzed commercial devices fail at gate voltages higher than 9-10 V, due to the extremely high electric field over the p-GaN/AlGaN stack; (iii) constant voltage stress tests indicate that the failure is also time-dependent and Weibull distributed. The several processes that can explain the time-dependent failure are discussed in the following.
Park, Sung Wook; Brenneman, Michael; Cooke, William H; Cordova, Alberto; Fogt, Donovan
The purpose was to determine if heart rate (HR) and heart rate variability (HRV) responses would reflect anaerobic threshold (AT) using a discontinuous, incremental, cycle test. AT was determined by ventilatory threshold (VT). Cyclists (30.6±5.9y; 7 males, 8 females) completed a discontinuous cycle test consisting of 7 stages (6 min each with 3 min of rest between). Three stages were performed at power outputs (W) below those corresponding to a previously established AT, one at W corresponding to AT, and 3 at W above those corresponding to AT. The W at the intersection of the trend lines was considered each metric's "threshold". The averaged stage data for Ve, HR, and time- and frequency-domain HRV metrics were plotted versus W. The W at the "threshold" for the metrics of interest were compared using correlation analysis and paired-sample t -test. In all, several heart rate-related parameters accurately reflected AT with significant correlations (p≤0.05) were observed between AT W and HR, mean RR interval (MRR), low and high frequency spectral energy (LF and HR, respectively), high frequency peak (fHF), and HFxfHF metrics' threshold W (i.e., MRRTW, etc.). Differences in HR or HRV metric threshold W and AT for all subjects were less than 14 W. The steady state data from discontinuous protocols may allow for a true indication of steady-state physiologic stress responses and corresponding W at AT, compared to continuous protocols using 1-2 min exercise stages.
Rosman, Jonathan; Hanon, Sam; Shapiro, Michael; Evans, Steven J; Schweitzer, Paul
2006-04-01
The mechanisms underlying the initiation of sustained ventricular tachycardia (VT) have not been fully elucidated. The extent to which reentry, abnormal automaticity, and triggered activity play a role in VT differs depending on the etiology of left ventricular dysfunction. By analyzing electrograms from implantable cardioverter defibrillator (ICD), we sought to determine whether there were differences in VT initiation patterns between patients with ischemic and nonischemic cardiomyopathy. We analyzed ICD electrograms in patients with ejection fractions < 40% who had sustained VT over a 27-month period. The trigger for VT onset was classified as a ventricular premature beat (VPB), supraventricular tachycardia, or of "sudden onset." The baseline cycle length, VT cycle length, coupling interval, and prematurity ratio were recorded for each event. The prematurity ratio was calculated as the coupling interval of the VT initiator divided by the baseline cycle length. Sixty-three VT events in 14 patients met the inclusion criteria. A VPB initiated the VT in 58 episodes (92%), 1 episode (2%) was initiated by a supraventricular tachycardia, and 4 episodes (6%) were sudden onset. The prematurity ratio was significantly higher (P < 0.05) in patients with ischemic cardiomyopathy (0.751 +/- 0.068) as compared to patients with nonischemic cardiomyopathy (0.604 +/- 0.139). VPBs initiated most sustained VT episodes. A significantly higher prematurity ratio was observed in the ischemic heart disease group. This may represent different mechanisms of VT initiation in patients with ischemic versus nonischemic heart disease.
Resonant tunneling via a Ru-dye complex using a nanoparticle bridge junction.
Nishijima, Satoshi; Otsuka, Yoichi; Ohoyama, Hiroshi; Kajimoto, Kentaro; Araki, Kento; Matsumoto, Takuya
2018-06-15
Nonlinear current-voltage (I-V) characteristics is an important property for the realization of information processing in molecular electronics. We studied the electrical conduction through a Ru-dye complex (N-719) on a 2-aminoethanethiol (2-AET) monolayer in a nanoparticle bridge junction system. The nonlinear I-V characteristics exhibited a threshold voltage at around 1.2 V and little temperature dependence. From the calculation of the molecular states using density functional theory and the energy alignment between the electrodes and molecules, the conduction mechanism in this system was considered to be resonant tunneling via the HOMO level of N-719. Our results indicate that the weak electronic coupling of electrodes and molecules is essential for obtaining nonlinear I-V characteristics with a clear threshold voltage that reflect the intrinsic molecular state.
NASA Astrophysics Data System (ADS)
Shin, Min-Seok; Jo, Yun-Rae; Kwon, Oh-Kyong
2011-03-01
In this paper, we propose a driving method for compensating the electrical instability of hydrogenated amorphous silicon (a-Si:H) thin film transistors (TFTs) and the luminance degradation of organic light-emitting diode (OLED) devices for large active matrix OLED (AMOLED) displays. The proposed driving method senses the electrical characteristics of a-Si:H TFTs and OLEDs using current integrators and compensates them by an external compensation method. Threshold voltage shift is controlled a using negative bias voltage. After applying the proposed driving method, the measured error of the maximum emission current ranges from -1.23 to +1.59 least significant bit (LSB) of a 10-bit gray scale under the threshold voltage shift ranging from -0.16 to 0.17 V.
NASA Astrophysics Data System (ADS)
Knorr, Nikolaus; Rosselli, Silvia; Miteva, Tzenka; Nelles, Gabriele
2009-06-01
Although charging of insulators by atomic force microscopy (AFM) has found widespread interest, often with data storage or nanoxerography in mind, less attention has been paid to the charging mechanism and the nature of the charge. Here we present a systematic study on charging of amorphous polymer films by voltage pulses applied to conducting AFM probes. We find a quadratic space charge limited current law of Kelvin probe force microscopy and electrostatic force microscopy peak volumes in pulse height, offset by a threshold voltage, and a power law in pulse width of positive exponents smaller than one. We interpret the results by a charging mechanism of injection and surface near accumulation of aqueous ions stemming from field induced water adsorption, with threshold voltages linked to the water affinities of the polymers.
Resonant tunneling via a Ru–dye complex using a nanoparticle bridge junction
NASA Astrophysics Data System (ADS)
Nishijima, Satoshi; Otsuka, Yoichi; Ohoyama, Hiroshi; Kajimoto, Kentaro; Araki, Kento; Matsumoto, Takuya
2018-06-01
Nonlinear current–voltage (I–V) characteristics is an important property for the realization of information processing in molecular electronics. We studied the electrical conduction through a Ru–dye complex (N-719) on a 2-aminoethanethiol (2-AET) monolayer in a nanoparticle bridge junction system. The nonlinear I–V characteristics exhibited a threshold voltage at around 1.2 V and little temperature dependence. From the calculation of the molecular states using density functional theory and the energy alignment between the electrodes and molecules, the conduction mechanism in this system was considered to be resonant tunneling via the HOMO level of N-719. Our results indicate that the weak electronic coupling of electrodes and molecules is essential for obtaining nonlinear I–V characteristics with a clear threshold voltage that reflect the intrinsic molecular state.
The influence of weight loss on anaerobic threshold in obese women.
Zak-Golab, Agnieszka; Zahorska-Markiewicz, Barbara; Langfort, Józef; Kocelak, Piotr; Holecki, Michal; Mizia-Stec, Katarzyna; Olszanecka-Glinianowicz, Magdalena; Chudek, Jerzy
2010-01-01
Obesity is associated with decreased physical activity. The aim of the study was to assess the anaerobic threshold in obese and normal weight women and to analyse the effect of weight-reduction therapy on the determined thresholds. 42 obese women without concomitant disease (age 30.5 ± 6.9y; BMI 33.6 ± 3.7 kg·m(-2)) and 19 healthy normal weight women (age 27.6 ± 7.0y; BMI 21.2 ± 1.9 kg·m(-2)) performed cycle ergometer incremental ramp exercise test up to exhaustion. The test was repeated in 19 obese women after 12.3 ± 4.2% weight loss. The lactate threshold (LT) and the ventilatory threshold (VT) were determined. Obese women had higher lactate (expressed as oxygen consumption) and ventilator threshold than normal weight women. The lactate threshold was higher than ventilatory one both in obese and normal weight women (1.11 ± 0.21 vs 0.88 ± 0.18 L·min(-1), p < 0.001; 0.94 ± 0.15 vs 0.79 ± 0.23 L·min(- 1), p < 0.01, respectively). After weight reduction therapy neither the lactate nor the ventilatory threshold changed significantly. The results concluded that; 1. The higher lactate threshold noted in obese women may be related to the increased fat acid usage in metabolism. 2. Both in obese and normal weight women lactate threshold appears at higher oxygen consumption than ventilatory threshold. 3. The obtained weight reduction, without weight normalisation was insufficient to cause significant changes of lactate and ventilatory thresholds in obese women. Key pointsResults showed that adolescent young female gymnasts have an altered serum inflammatory markers and endothelial activation, compared to their less physically active peers.Physical activities improved immune system.Differences in these biochemical data kept significant after adjustment for body weight and height.
Santangeli, Pasquale; Zado, Erica S; Supple, Gregory E; Haqqani, Haris M; Garcia, Fermin C; Tschabrunn, Cory M; Callans, David J; Lin, David; Dixit, Sanjay; Hutchinson, Mathew D; Riley, Michael P; Marchlinski, Francis E
2015-12-01
Catheter ablation of ventricular tachycardia (VT) in arrhythmogenic right ventricular cardiomyopathy improves short-term VT-free survival. We sought to determine the long-term outcomes of VT control and need for antiarrhythmic drug therapy after endocardial (ENDO) and adjuvant epicardial (EPI) substrate modification in patients with arrhythmogenic right ventricular cardiomyopathy. We examined 62 consecutive patients with Task Force criteria for arrhythmogenic right ventricular cardiomyopathy referred for VT ablation with a minimum follow-up of 1 year. Catheter ablation was guided by activation/entrainment mapping for tolerated VT and pacemapping/targeting of abnormal substrate for unmappable VT. Adjuvant EPI ablation was performed when recurrent VT or persistent inducibility after ENDO-only ablation. Endocardial plus adjuvant EPI ablation was performed in 39 (63%) patients, including 13 who crossed over to ENDO-EPI after VT recurrence during follow-up, after ENDO-only ablation. Before ablation, 54 of 62 patients failed a mean of 2.4 antiarrhythmic drugs, including amiodarone in 29 (47%) patients. During follow-up of 56±44 months after the last ablation, VT-free survival was 71% with only a single VT episode in additional 9 patients (15%). At last follow-up, 39 (64%) patients were only on β-blockers or no treatment, 21 were on class 1 or 3 antiarrhythmic drugs (11 for atrial arrhythmias), and 2 were on amiodarone as a bridge to heart transplantation. The long-term outcome after ENDO and adjuvant EPI substrate ablation of VT in arrhythmogenic right ventricular cardiomyopathy is good. Most patients have complete VT control without amiodarone therapy and limited need for antiarrhythmic drugs. © 2015 American Heart Association, Inc.
Di Biase, Luigi; Tung, Roderick; Szili-Torok, Tamás; Burkhardt, J David; Weiss, Peter; Tavernier, Rene; Berman, Adam E; Wissner, Erik; Spear, William; Chen, Xu; Neužil, Petr; Skoda, Jan; Lakkireddy, Dhanunjaya; Schwagten, Bruno; Lock, Ken; Natale, Andrea
2017-04-01
Patients with ischemic cardiomyopathy (ICM) are prone to scar-related ventricular tachycardia (VT). The success of VT ablation depends on accurate arrhythmogenic substrate localization, followed by optimal delivery of energy provided by constant electrode-tissue contact. Current manual and remote magnetic navigation (RMN)-guided ablation strategies aim to identify a reentry circuit and to target a critical isthmus through activation and entrainment mapping during ongoing tachycardia. The MAGNETIC VT trial will assess if VT ablation using the Niobe™ ES magnetic navigation system results in superior outcomes compared to a manual approach in subjects with ischemic scar VT and low ejection fraction. This is a randomized, single-blind, prospective, multicenter post-market study. A total of 386 subjects (193 per group) will be enrolled and randomized 1:1 between treatment with the Niobe ES system and treatment via a manual procedure at up to 20 sites. The study population will consist of patients with ischemic cardiomyopathy with left ventricular ejection fraction (LVEF) of ≤35% and implantable cardioverter defibrillator (ICD) who have sustained monomorphic VT. The primary study endpoint is freedom from any recurrence of VT through 12 months. The secondary endpoints are acute success; freedom from any VT at 1 year in a large-scar subpopulation; procedure-related major adverse events; and mortality rate through 12-month follow-up. Follow-up will consist of visits at 3, 6, 9, and 12 months, all of which will include ICD interrogation. The MAGNETIC VT trial will help determine whether substrate-based ablation of VT with RMN has clinical advantages over manual catheter manipulation. Clinicaltrials.gov identifier: NCT02637947.
Muser, Daniele; Santangeli, Pasquale; Pathak, Rajeev K; Castro, Simon A; Liang, Jackson J; Magnani, Silvia; Hayashi, Tatsuya; Garcia, Fermin C; Hutchinson, Mathew D; Supple, Gregory E; Frankel, David S; Riley, Michael P; Lin, David; Schaller, Robert D; Desjardins, Benoit; Dixit, Sanjay; Callans, David J; Zado, Erica S; Marchlinski, Francis E
2016-08-01
Catheter ablation (CA) of ventricular tachycardia (VT) in patients with cardiac sarcoidosis can be challenging because of the complex underlying substrate. We sought to determine the long-term outcome of CA of VT in patients with cardiac sarcoidosis. We enrolled 31 patients (age, 55±10 years) with diagnosis of cardiac sarcoidosis based on Heart Rhythm Society criteria and VT who underwent CA. In 23 (74%) patients, preprocedure cardiac magnetic resonance imaging and positron emission tomographic (PET) evaluation were performed. Preprocedure magnetic resonance imaging was positive for late gadolinium enhancement in 21 of 23 (91%) patients, whereas abnormal 18-fluorodeoxyglucose uptake was found in 15 of 23 (65%) cases. In 14 of 15 patients with positive PET at baseline, PET was repeated after 6.1±3.7-month follow-up. After a median follow-up of 2.5 (range, 0-10.5) years, 1 (3%) patient died and 4 (13%) underwent heart transplant. Overall VT-free survival was 55% at 2-year follow-up. Among the 16 (52%) patients with VT recurrences, CA resulted in a significant reduction of VT burden, with 8 (50%) having only isolated (1-3) VT episodes and only 1 patient with recurrent VT storm. The presence of late gadolinium enhancement at magnetic resonance imaging, a positive PET at baseline, and lack of PET improvement over follow-up were associated with increased risk of recurrent VT. In patients with cardiac sarcoidosis and VT, CA is effective in achieving long-term freedom from VT or improvement in VT burden in the majority of patients. The presence of late gadolinium enhancement at magnetic resonance imaging, a positive PET scan at baseline, or lack of improvement at repeat PET over follow-up predict worse arrhythmia-free survival. © 2016 American Heart Association, Inc.
Pre-Clinical Model to Study Recurrent Venous Thrombosis in the Inferior Vena Cava.
Andraska, Elizabeth A; Luke, Catherine E; Elfline, Megan A; Henke, Samuel P; Madapoosi, Siddharth S; Metz, Allan K; Hoinville, Megan E; Wakefield, Thomas W; Henke, Peter K; Diaz, Jose A
2018-06-01
Patients undergoing deep vein thrombosis (VT) have over 30% recurrence, directly increasing their risk of post-thrombotic syndrome. Current murine models of inferior vena cava (IVC) VT model host one thrombosis event. We aimed to develop a murine model to study IVC recurrent VT in mice. An initial VT was induced using the electrolytic IVC model (EIM) with constant blood flow. This approach takes advantage of the restored vein lumen 21 days after a single VT event in the EIM demonstrated by ultrasound. We then induced a second VT 21 days later, using either EIM or an IVC ligation model for comparison. The control groups were a sham surgery and, 21 days later, either EIM or IVC ligation. IVC wall and thrombus were harvested 2 days after the second insult and analysed for IVC and thrombus size, gene expression of fibrotic markers, histology for collagen and Western blot for citrullinated histone 3 (Cit-H3) and fibrin. Ultrasound confirmed the first VT and its progressive resolution with an anatomical channel allowing room for the second thrombus by day 21. As compared with a primary VT, recurrent VT has heavier walls with significant up-regulation of transforming growth factor-β (TGF-β), elastin, interleukin (IL)-6, matrix metallopeptidase 9 (MMP9), MMP2 and a thrombus with high citrullinated histone-3 and fibrin content. Experimental recurrent thrombi are structurally and compositionally different from the primary VT, with a greater pro-fibrotic remodelling vein wall profile. This work provides a VT recurrence IVC model that will help to improve the current understanding of the biological mechanisms and directed treatment of recurrent VT. Schattauer GmbH Stuttgart.
Hysteresis-Free Carbon Nanotube Field-Effect Transistors.
Park, Rebecca S; Hills, Gage; Sohn, Joon; Mitra, Subhasish; Shulaker, Max M; Wong, H-S Philip
2017-05-23
While carbon nanotube (CNT) field-effect transistors (CNFETs) promise high-performance and energy-efficient digital systems, large hysteresis degrades these potential CNFET benefits. As hysteresis is caused by traps surrounding the CNTs, previous works have shown that clean interfaces that are free of traps are important to minimize hysteresis. Our previous findings on the sources and physics of hysteresis in CNFETs enabled us to understand the influence of gate dielectric scaling on hysteresis. To begin with, we validate through simulations how scaling the gate dielectric thickness results in greater-than-expected benefits in reducing hysteresis. Leveraging this insight, we experimentally demonstrate reducing hysteresis to <0.5% of the gate-source voltage sweep range using a very large-scale integration compatible and solid-state technology, simply by fabricating CNFETs with a thin effective oxide thickness of 1.6 nm. However, even with negligible hysteresis, large subthreshold swing is still observed in the CNFETs with multiple CNTs per transistor. We show that the cause of large subthreshold swing is due to threshold voltage variation between individual CNTs. We also show that the source of this threshold voltage variation is not explained solely by variations in CNT diameters (as is often ascribed). Rather, other factors unrelated to the CNTs themselves (i.e., process variations, random fixed charges at interfaces) are a significant factor in CNT threshold voltage variations and thus need to be further improved.
NASA Astrophysics Data System (ADS)
Matys, M.; Kaneki, S.; Nishiguchi, K.; Adamowicz, B.; Hashizume, T.
2017-12-01
We proposed that the disorder induced gap states (DIGS) can be responsible for the threshold voltage (Vth) instability in Al2O3/AlGaN/GaN metal-oxide-semiconductor high-electron-mobility transistors. In order to verify this hypothesis, we performed the theoretical calculations of the capacitance voltage (C-V) curves for the Al2O3/AlGaN/GaN structures using the DIGS model and compared them with measured ones. We found that the experimental C-V curves with a complex hysteresis behavior varied with the maximum forward bias and the sweeping rate can be well reproduced theoretically by assuming a particular distribution in energy and space of the DIGS continuum near the Al2O3/AlGaN interface, i.e., a U-shaped energy density distribution and exponential depth decay from the interface into Al2O3 layer (up to 4 nm), as well as suitable DIGS capture cross sections (the order of magnitude of 10-15 cm2). Finally, we showed that the DIGS model can also explain the negative bias induced threshold voltage instability. We believe that these results should be critical for the successful development of the passivation techniques, which allows to minimize the Vth instability related effects.
NASA Astrophysics Data System (ADS)
Rhee, Jihyun; Choi, Sungju; Kang, Hara; Kim, Jae-Young; Ko, Daehyun; Ahn, Geumho; Jung, Haesun; Choi, Sung-Jin; Myong Kim, Dong; Kim, Dae Hwan
2018-02-01
Experimental extraction of the electron trap parameters which are associated with charge trapping into gate insulators under the positive bias temperature stress (PBTS) is proposed and demonstrated for the first time in amorphous indium-gallium-zinc-oxide thin-film transistors. This was done by combining the PBTS/recovery time-evolution of the experimentally decomposed threshold voltage shift (ΔVT) and the technology computer-aided design (TCAD)-based charge trapping simulation. The extracted parameters were the trap density (NOT) = 2.6 × 1018 cm-3, the trap energy level (ΔET) = 0.6 eV, and the capture cross section (σ0) = 3 × 10-19 cm2. Furthermore, based on the established TCAD framework, the relationship between the electron trap parameters and the activation energy (Ea) is comprehensively investigated. It is found that Ea increases with an increase in σ0, whereas Ea is independent of NOT. In addition, as ΔET increases, Ea decreases in the electron trapping-dominant regime (low ΔET) and increases again in the Poole-Frenkel (PF) emission/hopping-dominant regime (high ΔET). Moreover, our results suggest that the cross-over ΔET point originates from the complicated temperature-dependent competition between the capture rate and the emission rate. The PBTS bias dependence of the relationship between Ea and ΔET suggests that the electric field dependence of the PF emission-based electron hopping is stronger than that of the thermionic field emission-based electron trapping.
VTGRAPH - GRAPHIC SOFTWARE TOOL FOR VT TERMINALS
NASA Technical Reports Server (NTRS)
Wang, C.
1994-01-01
VTGRAPH is a graphics software tool for DEC/VT or VT compatible terminals which are widely used by government and industry. It is a FORTRAN or C-language callable library designed to allow the user to deal with many computer environments which use VT terminals for window management and graphic systems. It also provides a PLOT10-like package plus color or shade capability for VT240, VT241, and VT300 terminals. The program is transportable to many different computers which use VT terminals. With this graphics package, the user can easily design more friendly user interface programs and design PLOT10 programs on VT terminals with different computer systems. VTGRAPH was developed using the ReGis Graphics set which provides a full range of graphics capabilities. The basic VTGRAPH capabilities are as follows: window management, PLOT10 compatible drawing, generic program routines for two and three dimensional plotting, and color graphics or shaded graphics capability. The program was developed in VAX FORTRAN in 1988. VTGRAPH requires a ReGis graphics set terminal and a FORTRAN compiler. The program has been run on a DEC MicroVAX 3600 series computer operating under VMS 5.0, and has a virtual memory requirement of 5KB.
NASA Astrophysics Data System (ADS)
Enpuku, Keiji; Matsuo, Masaaki; Yoshida, Yujiro; Yamashita, Shigeya; Sasayama, Teruyoshi; Yoshida, Takashi
2018-06-01
We developed a magnetometer based on inductance modulation of a coil made from a high-critical-temperature superconducting material. The coil inductance was modulated over time via a modulation current applied to a magnetic wire that was inserted into the coil. The magnetic field was then converted into a signal voltage using this time-dependent inductance. The relationship between magnetometer performance and the modulation current conditions was studied. Under appropriate conditions, the magnetometer had responsivity of 885 V/T. The magnetic field noise was 1.3 pT/Hz1/2 in the white noise region and 5.6 pT/Hz1/2 at f = 1 Hz.
Dynamics of Action Potential Initiation in the GABAergic Thalamic Reticular Nucleus In Vivo
Muñoz, Fabián; Fuentealba, Pablo
2012-01-01
Understanding the neural mechanisms of action potential generation is critical to establish the way neural circuits generate and coordinate activity. Accordingly, we investigated the dynamics of action potential initiation in the GABAergic thalamic reticular nucleus (TRN) using in vivo intracellular recordings in cats in order to preserve anatomically-intact axo-dendritic distributions and naturally-occurring spatiotemporal patterns of synaptic activity in this structure that regulates the thalamic relay to neocortex. We found a wide operational range of voltage thresholds for action potentials, mostly due to intrinsic voltage-gated conductances and not synaptic activity driven by network oscillations. Varying levels of synchronous synaptic inputs produced fast rates of membrane potential depolarization preceding the action potential onset that were associated with lower thresholds and increased excitability, consistent with TRN neurons performing as coincidence detectors. On the other hand the presence of action potentials preceding any given spike was associated with more depolarized thresholds. The phase-plane trajectory of the action potential showed somato-dendritic propagation, but no obvious axon initial segment component, prominent in other neuronal classes and allegedly responsible for the high onset speed. Overall, our results suggest that TRN neurons could flexibly integrate synaptic inputs to discharge action potentials over wide voltage ranges, and perform as coincidence detectors and temporal integrators, supported by a dynamic action potential threshold. PMID:22279567
Lockwood, Christopher M; Moon, Jordan R; Smith, Abbie E; Tobkin, Sarah E; Kendall, Kristina L; Graef, Jennifer L; Cramer, Joel T; Stout, Jeffrey R
2010-08-01
Energy drink use has grown despite limited research to support efficacy or safety and amid concerns when combined with exercise. The purpose of this study was to assess the effects of 10 weeks of once-daily energy drink consumption or energy drink consumption with exercise on measures of body composition, cardiorespiratory fitness, strength, mood, and safety in previously sedentary males. Thirty-eight males were randomly assigned to energy drink + exercise (EX-A), energy drink (NEX-A), placebo + exercise (EX-B), or placebo (NEX-B). All participants consumed 1 drink per day for 10 weeks; EX-A and EX-B participated in 10 weeks of resistance and endurance exercise. Testing was performed before (PRE) and after (POST) the 10-week intervention. No significant (p > 0.05) changes were observed for body composition, fitness, or strength in NEX-A; however, significantly greater decreases in fat mass and percentage body fat and increases in VO2peak were observed in EX-A versus EX-B. Ventilatory threshold (VT), minute ventilation, VO2 at VT, and power output at VT improved significantly PRE to POST in EX-A but not in EX-B or nonexercising groups. Clinical markers for hepatic, renal, cardiovascular, and immune function, as determined by PRE and POST blood work revealed no adverse effects in response to the energy drink. Mood was not affected by energy drink use. Absent energy restriction or other dietary controls, chronic ingestion of a once-daily low-calorie energy drink appears ineffective at improving body composition, cardiorespiratory fitness, or strength in sedentary males. However, when combined with exercise, preworkout energy drink consumption may significantly improve some physiological adaptations to combined aerobic and resistance training.
al Makdessi, S; Sweidan, H; Dietz, K; Jacob, R
1999-04-01
The protective effect against reperfusion arrhythmias of a 3-month oral pretreatment with a dried extract of Crataegus oxyacantha (LI 132)(standardized to 2.2% flavonoids) was studied with the Langendorff heart of the rat after global no-flow ischemia. The heart was perfused with a modified Krebs-Henseleit solution in which the K+ content was reduced to 3.4 mmol/l in order to lower the fibrillation threshold. According to pilot experiments which considered various durations of global no-flow ischemia ranging from 10 to 20 minutes, two durations were chosen for the present study: 20 minutes (group 20) in which ventricular fibrillation (VF) was the predominant form of arrhythmias, and 18 minutes (group 18) in which the prevalence of VF was markedly lower despite the small difference in the duration of ischemia. Crataegus pretreatment significantly (p = 0.02) reduced the average prevalence of malignant arrhythmias (VF + Flutter) as observed during the 20-min-period of reperfusion as follows: group 20: from 89% (control, n = 9) to 51% (LI 132, n = 7), group 18: from 48% (control, n = 8) to 8% (LI 132, n = 8). In group 20, ventricular tachycardia (VT) could be observed only in the treated group, because of the predominance of VF in the control group. LI 132 pretreatment reduced the average prevalence of VT in group 18 in spite of the identical percentage of occurrence (6 out of 8 rats, with and without treatment) due to a shorter duration of the VT episodes. Thus, under the conditions of our experiments, effective prevention against reperfusion arrhythmias by Crataegus pretreatment was evident.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dale, R.; Sáez, D., E-mail: rdale@umh.es, E-mail: diego.saez@uv.es
The vector-tensor (VT) theory of gravitation revisited in this article was studied in previous papers, where it was proved that VT works and deserves attention. New observational data and numerical codes have motivated further development which is presented here. New research has been planed with the essential aim of proving that current cosmological observations, including Planck data, baryon acoustic oscillations (BAO), and so on, may be explained with VT, a theory which accounts for a kind of dark energy which has the same equation of state as vacuum. New versions of the codes CAMB and COSMOMC have been designed formore » applications to VT, and the resulting versions have been used to get the cosmological parameters of the VT model at suitable confidence levels. The parameters to be estimated are the same as in general relativity (GR), plus a new parameter D . For D = 0, VT linear cosmological perturbations reduces to those of GR, but the VT background may explain dark energy. The fits between observations and VT predictions lead to non vanishing | D | upper limits at the 1σ confidence level. The value D = 0 is admissible at this level, but this value is not that of the best fit in any case. Results strongly suggest that VT may explain current observations, at least, as well as GR; with the advantage that, as it is proved in this paper, VT has an additional parameter which facilitates adjustments to current observational data.« less
Acute severe asthma: performance of ventilator at simulated altitude.
Tourtier, Jean-Pierre; Forsans, Emma; Leclerc, Thomas; Libert, Nicolas; Ramsang, Solange; Tazarourte, Karim; Man, Michel; Borne, Marc
2011-04-01
Exacerbation of asthma can be seen during air transport. Severe patients, not responding to conventional therapy, require ventilator support. We evaluated the performance of two transport ventilators, built with turbine technology, the T-birdVSO2 and the LTV-1000, for use during aeromedical evacuation of acute severe asthma. We have assessed the ability of both the ventilators to deliver to an acute severe asthma model a tidal volume (Vt) set at different simulated altitudes, by changing the ambient air pressure. The simulated cabin altitudes were 1500, 2500, and 3000 m (decompression chamber). Vt was set at 700 and 400 ml in an acute severe asthma lung model. Comparisons of the preset with the actual measured values were accomplished using a t-test. Comparisons between the actual delivered Vt and set Vt showed a significant difference starting at 1500 m for both the ventilators. The T-birdVSO2 showed a decrease in the volume delivered, with a negative variation of more than 10% compared with the Vt set. The LTV-1000 showed mostly an increase in the volume delivered. The delivered Vt remained within 10% of the set Vt. The accuracy of Vt delivery was superior with the LTV-1000 than with the T-birdVSO2, but the higher delivered Vt of the LTV-1000 are likely to be more harmful than lower delivered Vt of the T-birdVSO2.
Samore, Naseer Ahmed; Imran Majeed, Syed Muhammad; Kayani, Azhar Mahmud; Bhalli, Muhammad Asif; Shabbir, Muhammad
2009-09-01
To determine the outcome of Radiofrequency Catheter Ablation (RFCA) as a non-pharmacological curative therapy for idiopathic Ventricular Tachycardia (VT) and to identify procedure-related complications. Descriptive study. The Armed Forces Institute of Cardiology and National Institute of Heart Diseases, Rawalpindi, from February 2001 to October 2008. Ninety eight consecutive patients with idiopathic VT, resistant to drug therapy, who underwent Electrophysiology Studies (EPS) radiofrequency catheter ablation were enrolled. Clinical and electrophysiological variables were recorded and a descriptive analysis was done. Out of the 98 patients, 79 were males (80.6%). The mean age was 33.29+11.93 years. Modes of presentation were sustained VT, Repetitive Monomorphic VT (RMVT), Non-sustained VT (NSVT) and Ventricular Premature Beats (VPBs). Right Ventricular Outflow Tract (RVOT) VT was found in 37 patients, 37 had Idiopathic Left Ventricular Tachycardia (ILVT), 20 had Left Ventricular Outflow Tract (LVOT) VT, and Inflow Right Ventricular Tachycardia (IRVT) was found in 7 patients. Other sites of origin of VT were infrequent. Eight patients had dual morphologies of VT. Atrioventricular Nodal Re-entry Tachycardia (AVNRT) was found in 8 patients. RFCA was successful in abolishing inducible VT in 88 patients. One patient developed complete AV block requiring a permanent pacemaker. Results of this study confirm a high degree of success and safety of radiofrequency catheter ablation as curative therapy for idiopathic ventricular tachycardia.
Transistor biased amplifier minimizes diode discriminator threshold attenuation
NASA Technical Reports Server (NTRS)
Larsen, R. N.
1967-01-01
Transistor biased amplifier has a biased diode discriminator driven by a high impedance /several megohms/ current source, rather than a voltage source with several hundred ohms output impedance. This high impedance input arrangement makes the incremental impedance of the threshold diode negligible relative to the input impedance.
NASA Astrophysics Data System (ADS)
Watanabe, Takeshi; Tada, Keisuke; Yasuno, Satoshi; Oji, Hiroshi; Yoshimoto, Noriyuki; Hirosawa, Ichiro
2016-03-01
The effect of gate voltage on electric potential in a pentacene (PEN) layer was studied by hard X-ray photoelectron spectroscopy under a bias voltage. It was observed that applying a negative gate voltage substantially increases the width of a C 1s peak. This suggested that injected and accumulated carriers in an organic thin film transistor channel modified the potential depth profile in PEN. It was also observed that the C 1s kinetic energy tends to increase monotonically with threshold voltage.
Systems and methods for initializing a charging system
Ransom, Ray M.; Perisic, Milun; Kajouke, Lateef A.
2014-09-09
Systems and methods are provided for initiating a charging system. The method, for example, may include, but is not limited to, providing, by the charging system, an incrementally increasing voltage to a battery up to a first predetermined threshold while the energy conversion module has a zero-percent duty cycle, providing, by the charging system, an incrementally increasing voltage to the battery from an initial voltage level of the battery up to a peak voltage of a voltage source while the energy conversion module has a zero-percent duty cycle, and providing, by the charging system, an incrementally increasing voltage to the battery by incrementally increasing the duty cycle of the energy conversion module.
Maia, Lígia de A; Samary, Cynthia S; Oliveira, Milena V; Santos, Cintia L; Huhle, Robert; Capelozzi, Vera L; Morales, Marcelo M; Schultz, Marcus J; Abreu, Marcelo G; Pelosi, Paolo; Silva, Pedro L; Rocco, Patricia Rieken Macedo
2017-10-01
Intraoperative mechanical ventilation may yield lung injury. To date, there is no consensus regarding the best ventilator strategy for abdominal surgery. We aimed to investigate the impact of the mechanical ventilation strategies used in 2 recent trials (Intraoperative Protective Ventilation [IMPROVE] trial and Protective Ventilation using High versus Low PEEP [PROVHILO] trial) on driving pressure (ΔPRS), mechanical power, and lung damage in a model of open abdominal surgery. Thirty-five Wistar rats were used, of which 28 were anesthetized, and a laparotomy was performed with standardized bowel manipulation. Postoperatively, animals (n = 7/group) were randomly assigned to 4 hours of ventilation with: (1) tidal volume (VT) = 7 mL/kg and positive end-expiratory pressure (PEEP) = 1 cm H2O without recruitment maneuvers (RMs) (low VT/low PEEP/RM-), mimicking the low-VT/low-PEEP strategy of PROVHILO; (2) VT = 7 mL/kg and PEEP = 3 cm H2O with RMs before laparotomy and hourly thereafter (low VT/moderate PEEP/4 RM+), mimicking the protective ventilation strategy of IMPROVE; (3) VT = 7 mL/kg and PEEP = 6 cm H2O with RMs only before laparotomy (low VT/high PEEP/1 RM+), mimicking the strategy used after intubation and before extubation in PROVHILO; or (4) VT = 14 mL/kg and PEEP = 1 cm H2O without RMs (high VT/low PEEP/RM-), mimicking conventional ventilation used in IMPROVE. Seven rats were not tracheotomized, operated, or mechanically ventilated, and constituted the healthy nonoperated and nonventilated controls. Low VT/moderate PEEP/4 RM+ and low VT/high PEEP/1 RM+, compared to low VT/low PEEP/RM- and high VT/low PEEP/RM-, resulted in lower ΔPRS (7.1 ± 0.8 and 10.2 ± 2.1 cm H2O vs 13.9 ± 0.9 and 16.9 ± 0.8 cm H2O, respectively; P< .001) and less mechanical power (63 ± 7 and 79 ± 20 J/min vs 110 ± 10 and 120 ± 20 J/min, respectively; P = .007). Low VT/high PEEP/1 RM+ was associated with less alveolar collapse than low VT/low PEEP/RM- (P = .03). E-cadherin expression was higher in low VT/moderate PEEP/4 RM+ than in low VT/low PEEP/RM- (P = .013) or high VT/low PEEP/RM- (P = .014). The extent of alveolar collapse, E-cadherin expression, and tumor necrosis factor-alpha correlated with ΔPRS (r = 0.54 [P = .02], r = -0.48 [P = .05], and r = 0.59 [P = .09], respectively) and mechanical power (r = 0.57 [P = .02], r = -0.54 [P = .02], and r = 0.48 [P = .04], respectively). In this model of open abdominal surgery based on the mechanical ventilation strategies used in IMPROVE and PROVHILO trials, lower mechanical power and its surrogate ΔPRS were associated with reduced lung damage.
Allen, Zachery W [Mandan, ND; Zevenbergen, Gary A [Arvada, CO
2012-04-03
A device and method for detecting ground potential rise (GPR) comprising positioning a first electrode and a second electrode at a distance from each other into the earth. The voltage of the first electrode and second electrode is attenuated by an attenuation factor creating an attenuated voltage. The true RMS voltage of the attenuated voltage is determined creating an attenuated true RMS voltage. The attenuated true RMS voltage is then multiplied by the attenuation factor creating a calculated true RMS voltage. If the calculated true RMS voltage is greater than a first predetermined voltage threshold, a first alarm is enabled at a local location. If user input is received at a remote location acknowledging the first alarm, a first alarm acknowledgment signal is transmitted. The first alarm acknowledgment signal is then received at which time the first alarm is disabled.
Sudden cardiac arrest in people with epilepsy in the community
Lamberts, Robert J.; Blom, Marieke T.; Wassenaar, Merel; Bardai, Abdennasser; Leijten, Frans S.; de Haan, Gerrit-Jan; Sander, Josemir W.; Thijs, Roland D.
2015-01-01
Objective: To ascertain whether characteristics of ventricular tachycardia/fibrillation (VT/VF) differed between people with epilepsy and those without and which individuals with epilepsy were at highest risk. Methods: We ascertained 18 people with active epilepsy identified in a community-based registry of sudden cardiac arrest (SCA) with ECG-confirmed VT/VF (cases). We compared them with 470 individuals with VT/VF without epilepsy (VT/VF controls) and 54 individuals with epilepsy without VT/VF (epilepsy controls). Data on comorbidity, epilepsy severity, and medication use were collected and entered into (conditional) logistic regression models to identify determinants of VT/VF in epilepsy. Results: In most cases, there was an obvious (10/18) or presumed cardiovascular cause (5/18) in view of preexisting heart disease. In 2 of the 3 remaining events, near–sudden unexpected death in epilepsy (SUDEP) was established after successful resuscitation. Cases had a higher prevalence of congenital/inherited heart disease (17% vs 1%, p = 0.002), and experienced VT/VF at younger age (57 vs 64 years, p = 0.023) than VT/VF controls. VT/VF in cases occurred more frequently at/near home (89% vs 58%, p = 0.009), and was less frequently witnessed (72% vs 89%, p = 0.048) than in VT/VF controls. Cases more frequently had clinically relevant heart disease (50% vs 15%, p = 0.005) and intellectual disability (28% vs 1%, p < 0.001) than epilepsy controls. Conclusion: Cardiovascular disease rather than epilepsy characteristics is the main determinant of VT/VF in people with epilepsy in the community. SCA and SUDEP are partially overlapping disease entities. PMID:26092917
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chida, K.; Yamauchi, Y.; Arakawa, T.
2013-12-04
We performed the resistively-detected nuclear magnetic resonance (RDNMR) to study the electron spin polarization in the non-equilibrium quantum Hall regime. By measuring the Knight shift, we derive source-drain bias voltage dependence of the electron spin polarization in quantum wires. The electron spin polarization shows minimum value around the threshold voltage of the dynamic nuclear polarization.
Interfacial fields in organic field-effect transistors and sensors
NASA Astrophysics Data System (ADS)
Dawidczyk, Thomas J.
Organic electronics are currently being commercialized and present a viable alternative to conventional electronics. These organic materials offer the ability to chemically manipulate the molecule, allowing for more facile mass processing techniques, which in turn reduces the cost. One application where organic semiconductors (OSCs) are being investigated is sensors. This work evaluates an assortment of n- and p-channel semiconductors as organic field-effect transistor (OFET) sensors. The sensor responses to dinitrotoluene (DNT) vapor and solid along with trinitrotoluene (TNT) solid were studied. Different semiconductor materials give different magnitude and direction of electrical current response upon exposure to DNT. Additional OFET parameters---mobility and threshold voltage---further refine the response to the DNT with each OFET sensor requiring a certain gate voltage for an optimized response to the vapor. The pattern of responses has sufficient diversity to distinguish DNT from other vapors. To effectively use these OFET sensors in a circuit, the threshold voltage needs to be tuned for each transistor to increase the efficiency of the circuit and maximize the sensor response. The threshold voltage can be altered by embedding charges into the dielectric layer of the OFET. To study the quantity and energy of charges needed to alter the threshold voltage, charge carriers were injected into polystyrene (PS) and investigated with scanning Kelvin probe microscopy (SKPM) and thermally stimulated discharge current (TSDC). Lateral heterojunctions of pentacene/PS were scanned using SKPM, effectively observing polarization along a side view of a lateral nonvolatile organic field-effect transistor dielectric interface. TSDC was used to observe charge migration out of PS films and to estimate the trap energy level inside the PS, using the initial rise method. The process was further refined to create lateral heterojunctions that were actual working OFETs, consisting of a PS or poly (3-trifluoro)styrene (F-PS) gate dielectric and a pentacene OSC. The charge storage inside the dielectric was visualized with SKPM, correlated to a threshold voltage shift in the transistor operation, and related to bias stress as well. The SKPM method allows the dielectric/OSC interface of the OFET to be visualized without any alteration of the OFET. Furthermore, this technique allows for the observation of charge distribution between the two dielectric interfaces, PS and F-PS. The SKPM is used to visualize the charge from conventional gate biasing and also as a result of embedding charges deliberately into the dielectric to shift the threshold voltage. Conventional gate biasing shows considerable residual charge in the PS dielectric, which results in gate bias stress. Gate bias stress is one of the major hurdles left in the commercialization of OFETs. To prevent this bias stress, additives of different energy levels were inserted into the dielectric to limit the gate bias stress. Additionally, the dielectrics were pre-charged to try and prevent further bias stress. Neither pre-charging the dielectric or the addition of additive has been used in gate bias prevention, but both methods offer improved resistance to gate bias stress, and help to further refine the dielectric design.
Feature Weighting via Optimal Thresholding for Video Analysis (Open Access)
2014-03-03
EKF MKL LPBoost ALF FWOT BP CaVT FMG GaVU GaA MaS PR PK RaA WaSP Mean 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 P m is s@ T E R = 1 2 .5 Trajectory EKF MKL...processing, and finance. SIAM Journal on Op- timization, 19(3):1344–1367, 2008. [8] H. Kuehne, H. Jhuang, E . Garrote, T. Poggio, and T. Serre. HMDB: a large...Vitaladevuni, X. Zhuang, S. Tsakalidis , U. Park, and R. Prasad. Multimodal feature fusion for robust event detection in web videos. In CVPR, 2012. [16] A
NASA Astrophysics Data System (ADS)
Yi, Guosheng; Wang, Jiang; Wei, Xile; Deng, Bin; Li, Huiyan; Che, Yanqiu
2017-06-01
Spike-frequency adaptation (SFA) mediated by various adaptation currents, such as voltage-gated K+ current (IM), Ca2+-gated K+ current (IAHP), or Na+-activated K+ current (IKNa), exists in many types of neurons, which has been shown to effectively shape their information transmission properties on slow timescales. Here we use conductance-based models to investigate how the activation of three adaptation currents regulates the threshold voltage for action potential (AP) initiation during the course of SFA. It is observed that the spike threshold gets depolarized and the rate of membrane depolarization (dV/dt) preceding AP is reduced as adaptation currents reduce firing rate. It is indicated that the presence of inhibitory adaptation currents enables the neuron to generate a dynamic threshold inversely correlated with preceding dV/dt on slower timescales than fast dynamics of AP generation. By analyzing the interactions of ionic currents at subthreshold potentials, we find that the activation of adaptation currents increase the outward level of net membrane current prior to AP initiation, which antagonizes inward Na+ to result in a depolarized threshold and lower dV/dt from one AP to the next. Our simulations demonstrate that the threshold dynamics on slow timescales is a secondary effect caused by the activation of adaptation currents. These findings have provided a biophysical interpretation of the relationship between adaptation currents and spike threshold.
Suppression of threshold voltage variability in MOSFETs by adjustment of ion implantation parameters
NASA Astrophysics Data System (ADS)
Park, Jae Hyun; Chang, Tae-sig; Kim, Minsuk; Woo, Sola; Kim, Sangsig
2018-01-01
In this study, we investigate threshold voltage (VTH) variability of metal-oxide-semiconductor field-effect transistors induced by random dopant fluctuation (RDF). Our simulation work demonstrates not only the influence of the implantation parameters such as its dose, tilt angle, energy, and rotation angle on the RDF-induced VTH variability, but also the solution to reduce the effect of this variability. By adjusting the ion implantation parameters, the 3σ (VTH) is reduced from 43.8 mV to 28.9 mV. This 34% reduction is significant, considering that our technique is very cost effective and facilitates easy fabrication, increasing availability.
Park, Byoungnam; Whitham, Kevin; Bian, Kaifu; Lim, Yee-Fun; Hanrath, Tobias
2014-12-21
We used a bilayer field effect transistor (FET) consisting of a thin PbS nanocrystals (NCs) film interfaced with vacuum-deposited pentacene to probe trap states in NCs. We interpret the observed threshold voltage shift in context of charge carrier trapping by PbS NCs and relate the magnitude of the threshold voltage shift to the number of trapped carriers. We explored a series of NC surface ligands to modify the interface between PbS NCs and pentacene and demonstrate the impact of interface chemistry on charge carrier density and the FET mobility in a pentacene FET.
Static Noise Margin Enhancement by Flex-Pass-Gate SRAM
NASA Astrophysics Data System (ADS)
O'Uchi, Shin-Ichi; Masahara, Meishoku; Sakamoto, Kunihiro; Endo, Kazuhiko; Liu, Yungxun; Matsukawa, Takashi; Sekigawa, Toshihiro; Koike, Hanpei; Suzuki, Eiichi
A Flex-Pass-Gate SRAM, i.e. a fin-type-field-effect-transistor- (FinFET-) based SRAM, is proposed to enhance noise margin during both read and write operations. In its cell, the flip-flop is composed of usual three-terminal- (3T-) FinFETs while pass gates are composed of four-terminal- (4T-) FinFETs. The 4T-FinFETs enable to adopt a dynamic threshold-voltage control in the pass gates. During a write operation, the threshold voltage of the pass gates is lowered to enhance the writing speed and stability. During the read operation, on the other hand, the threshold voltage is raised to enhance the static noise margin. An asymmetric-oxide 4T-FinFET is helpful to manage the leakage current through the pass gate. In this paper, a design strategy of the pass gate with an asymmetric gate oxide is considered, and a TCAD-based Monte Carlo simulation reveals that the Flex-Pass-Gate SRAM based on that design strategy is expected to be effective in half-pitch 32-nm technology for low-standby-power (LSTP) applications, even taking into account the variability in the device performance.
NASA Astrophysics Data System (ADS)
Kawamura, Yumi; Tani, Mai; Hattori, Nozomu; Miyatake, Naomasa; Horita, Masahiro; Ishikawa, Yasuaki; Uraoka, Yukiharu
2012-02-01
We investigated zinc oxide (ZnO) thin films prepared by plasma assisted atomic layer deposition (PA-ALD), and thin-film transistors (TFTs) with the ALD ZnO channel layer for application to next-generation displays. We deposited the ZnO channel layer by PA-ALD at 100 or 300 °C, and fabricated TFTs. The transfer characteristic of the 300 °C-deposited ZnO TFT exhibited high mobility (5.7 cm2 V-1 s-1), although the threshold voltage largely shifted toward the negative (-16 V). Furthermore, we deposited Al2O3 thin film as a gate insulator by PA-ALD at 100 °C for the low-temperature TFT fabrication process. In the case of ZnO TFTs with the Al2O3 gate insulator, the shift of the threshold voltage improved (-0.1 V). This improvement of the negative shift seems to be due to the negative charges of the Al2O3 film deposited by PA-ALD. On the basis of the experimental results, we confirmed that the threshold voltage of ZnO TFTs is controlled by PA-ALD for the deposition of the gate insulator.
IGZO TFT-based circuit with tunable threshold voltage by laser annealing
NASA Astrophysics Data System (ADS)
Huang, Xiaoming; Yu, Guang; Wu, Chenfei
2017-11-01
In this work, a high-performance inverter based on amorphous indium-gallium-zinc oxide thin-film transistors (TFTs) has been fabricated, which consists of a driver TFT and a load TFT. The threshold voltage (Vth) of the load TFT can be tuned by applying an area-selective laser annealing. The transfer curve of the load TFT shows a parallel shift into the negative bias direction upon laser annealing. Based on x-ray photoelectron spectroscopy analyses, the negative Vth shift can be attributed to the increase of oxygen vacancy concentration within the device channel upon laser irradiation. Compared to the untreated inverter, the laser annealed inverter shows much improved switching characteristics, including a large output swing range which is close to full swing, as well as an enhanced output voltage gain. Furthermore, the dynamic performance of ring oscillator based on the laser-annealed inverter is improved.
Pseudo-diode based on protonic/electronic hybrid oxide transistor
NASA Astrophysics Data System (ADS)
Fu, Yang Ming; Liu, Yang Hui; Zhu, Li Qiang; Xiao, Hui; Song, An Ran
2018-01-01
Current rectification behavior has been proved to be essential in modern electronics. Here, a pseudo-diode is proposed based on protonic/electronic hybrid indium-gallium-zinc oxide electric-double-layer (EDL) transistor. The oxide EDL transistors are fabricated by using phosphorous silicate glass (PSG) based proton conducting electrolyte as gate dielectric. A diode operation mode is established on the transistor, originating from field configurable proton fluxes within the PSG electrolyte. Current rectification ratios have been modulated to values ranged between ˜4 and ˜50 000 with gate electrode biased at voltages ranged between -0.7 V and 0.1 V. Interestingly, the proposed pseudo-diode also exhibits field reconfigurable threshold voltages. When the gate is biased at -0.5 V and 0.3 V, threshold voltages are set to ˜-1.3 V and -0.55 V, respectively. The proposed pseudo-diode may find potential applications in brain-inspired platforms and low-power portable systems.
Verocytotoxin-induced apoptosis of human microvascular endothelial cells.
Pijpers, A H; van Setten, P A; van den Heuvel, L P; Assmann, K J; Dijkman, H B; Pennings, A H; Monnens, L A; van Hinsbergh, V W
2001-04-01
The pathogenesis of the epidemic form of hemolytic uremic syndrome is characterized by endothelial cell damage. In this study, the role of apoptosis in verocytotoxin (VT)-mediated endothelial cell death in human glomerular microvascular endothelial cells (GMVEC), human umbilical vein endothelial cells, and foreskin microvascular endothelial cells (FMVEC) was investigated. VT induced apoptosis in GMVEC and human umbilical vein endothelial cells when the cells were prestimulated with the inflammatory mediator tumor necrosis factor-alpha (TNF-alpha). FMVEC displayed strong binding of VT and high susceptibility to VT under basal conditions, which made them suitable for the study of VT-induced apoptosis without TNF-alpha interference. On the basis of functional (flow cytometry and immunofluorescence microscopy using FITC-conjugated annexin V and propidium iodide), morphologic (transmission electron microscopy), and molecular (agarose gel electrophoresis of cellular DNA fragments) criteria, it was documented that VT induced programmed cell death in microvascular endothelial cells in a dose- and time-dependent manner. Furthermore, whereas partial inhibition of protein synthesis by VT was associated with a considerable number of apoptotic cells, comparable inhibition of protein synthesis by cycloheximide was not. This suggests that additional pathways, independent of protein synthesis inhibition, may be involved in VT-mediated apoptosis in microvascular endothelial cells. Specific inhibition of caspases by Ac-Asp-Glu-Val-Asp-CHO, but not by Ac-Tyr-Val-Ala-Asp-CHO, was accompanied by inhibition of VT-induced apoptosis in FMVEC and TNF-alpha-treated GMVEC. These data indicate that VT can induce apoptosis in human microvascular endothelial cells.
Giudici, Marcela; Pascual, Roberto; de la Canal, Laura; Pfüller, Karola; Pfüller, Uwe; Villalaín, José
2003-01-01
Viscotoxins are small proteins that are thought to interact with biomembranes, displaying different toxic activities against a varied number of cell types, being viscotoxin A3 (VtA3) the most cytotoxic whereas viscotoxin B (VtB) is the less potent. By using infrared and fluorescence spectroscopies, we have studied the interaction of VtA3 and VtB, both wild and reduced ones, with model membranes containing negatively charged phospholipids. Both VtA3 and VtB present a high conformational stability, and a similar conformation both in solution and when bound to membranes. In solution, the infrared spectra of the reduced proteins show an increase in bandwidth compared to the nonreduced ones indicating a greater flexibility. VtA3 and VtB bind with high affinity to membranes containing negatively charged phospholipids and are motional restricted, their binding being dependent on phospholipid composition. Whereas nonreduced proteins maintain their structure when bound to membranes, reduced ones aggregate. Furthermore, leakage experiments show that wild proteins were capable of disrupting membranes whereas reduced proteins were not. The effect of VtA3 and VtB on membranes having different phospholipid composition is diverse, affecting the cooperativity and fluidity of the membranes. Viscotoxins interact with membranes in a complex way, most likely organizing themselves at the surface inducing the appearance of defects that lead to the destabilization and disruption of the membrane bilayer. PMID:12885644
Luo, Bin; Zhou, Gongbu; Guo, Xiaogang; Liu, Xu; Yang, Jiandu; Sun, Qi; Ma, Jian; Zhang, Shu
2017-06-01
The present study aimed to retrospectively investigate long-term clinical outcomes of patients undergoing catheter ablation of left posterior fascicular ventricular tachycardia (LPF-VT) with the development of left posterior fascicular block (LPF block) and characteristics of repeat procedures. A total of 195 patients (mean age 29.76±1.03years, 16.4% females) who underwent catheter ablation for LPF-VT were consecutively enrolled. The earliest ventricular potential with a single fused Purkinje potential (PP) during VT and the PP located in the inferior-apical or mid-apical septum during SR were targeted for linear ablation. The endpoint of the procedure was noninducible VT and development of new-onset LPF block. Follow-up with clinic visits or telephonic interviews, electrocardiogram (ECG), or Holter monitoring was performed after the procedure. With a median follow-up of 85 (18,181) months, 20 patients were censored and 152 of 175 (86.86%) patients had long-term freedom from VT after a single procedure. No statistical difference in the outcome of catheter ablation of LPF-VT was found between inducible and non-inducible groups (P=0.89). Twenty-three patients exhibited recurrent LPF-VT. Seven of 23 patients developed new-onset left upper septal ventricular tachycardia that was successfully ablated. All the patients undergoing repeat procedures had freedom from VT. No procedural complications occurred. Ablation of LPF-VT using the development of LPF block as the endpoint is associated with a high procedural success rate. No difference in freedom from LPF-VT was found between inducible and non-inducible patients. New-onset LPF block recovery and non-early PP-QRS interval can be the predictors of LPF-VT repeat procedure. Copyright © 2017 Elsevier B.V. All rights reserved.
Hoekstra, W. J.; Schotzinger, R. J.; Sobel, J. D.; Lilly, E. A.; Fidel, P. L.
2015-01-01
Vulvovaginal candidiasis (VVC) and recurrent VVC (RVVC) remain major health problems for women. VT-1161, a novel fungal CYP51 inhibitor which has potent antifungal activity against fluconazole-sensitive Candida albicans, retained its in vitro potency (MIC50 of ≤0.015 and MIC90 of 0.12 μg/ml) against 10 clinical isolates from VVC or RVVC patients resistant to fluconazole (MIC50 of 8 and MIC90 of 64 μg/ml). VT-1161 pharmacokinetics in mice displayed a high volume of distribution (1.4 liters/kg), high oral absorption (73%), and a long half-life (>48 h) and showed rapid penetration into vaginal tissue. In a murine model of vaginal candidiasis using fluconazole-sensitive yeast, oral doses as low as 4 mg/kg VT-1161 significantly reduced the fungal burden 1 and 4 days posttreatment (P < 0.0001). Similar VT-1161 efficacy was measured when an isolate highly resistant to fluconazole (MIC of 64 μg/ml) but fully sensitive in vitro to VT-1161 was used. When an isolate partially sensitive to VT-1161 (MIC of 0.12 μg/ml) and moderately resistant to fluconazole (MIC of 8 μg/ml) was used, VT-1161 remained efficacious, whereas fluconazole was efficacious on day 1 but did not sustain efficacy 4 days posttreatment. Both agents were inactive in treating an infection with an isolate that demonstrated weaker potency (MICs of 2 and 64 μg/ml for VT-1161 and fluconazole, respectively). Finally, the plasma concentrations of free VT-1161 were predictive of efficacy when in excess of the in vitro MIC values. These data support the clinical development of VT-1161 as a potentially more efficacious treatment for VVC and RVVC. PMID:26124165
Škerk, Vedrana; Markotić, Alemka; Brkljačić, Diana Delić; Manola, Šime; Krčmar, Tomislav; Gabrić, Ivo Darko; Štajminger, Gordana; Pintarić, Hrvoje
2013-01-01
Background Ventricular tachycardia (VT) is frequently seen in ischemic settings like acute myocardial infarction with ST segment elevation (STEMI). Endothelial dysfunction (ED) represents inflammation and the loss of all protective features of the endothelium. We aimed to examine the association between VT and ED in patients with STEMI. Material/Methods The study included 90 subjects (30 with VT and acute STEMI, 30 with STEMI without VT, and 30 controls). Sera of all subjects were tested on ED markers by enzyme immunoassay: sICAM-1 (intracellular adhesive molecule-1), sVCAM-1 (vascular adhesive molecule-1), P- and E-selectins, and VEGF (vascular endothelial growth factor). In addition, CRP (C-reactive protein) was detected. Results Significantly increased values of low-density lipoprotein, triglycerides, leukocytes, creatinine, and the number of cigarettes smoked were observed among patients with VT+STEMI in comparison to controls. The levels of E-selectin were significantly lower in the VT+STEMI group than in the other groups, while the levels of VCAM-1 were significantly higher in the groups with STEMI and VT+STEMI compared to the controls. Lower levels of VEGF were recorded in STEMI and VT+STEMI groups compared to the control group. A significant correlation between CRP and VCAM-1 in patients with VT +STEMI was demonstrated. Conclusions We showed that ED may have a role in the immunopathogenesis of VT in patients with STEMI. The role of sE-selectin and correlation of sVCAM-1 with CRP as possible ED predictive markers in patients with VT+STEMI should be further investigated in a large cohort of patients. PMID:24253420
The Association of Statin Therapy with the Risk of Recurrent Venous Thrombosis
Smith, Nicholas L.; Harrington, Laura B.; Blondon, Marc; Wiggins, Kerri L.; Floyd, James S.; Sitlani, Colleen M.; McKnight, Barbara; Larson, Eric B.; Rosendaal, Frits R.; Heckbert, Susan R.; Psaty, Bruce M.
2016-01-01
Background Meta-analyses of randomized controlled trials suggest that treatment with HMG-CoA reductase inhibitors (statins) lowers the risk of incident venous thrombosis (VT), particularly among those without prevalent clinical cardiovascular disease (CVD). Whether this is true for the prevention of recurrent VT is debated. We used an observational inception cohort to estimate the association of current statin use with the risk of recurrent VT. Methods and Results The study setting was a large healthcare organization with detailed medical record and pharmacy information at cohort entry and throughout follow-up. We followed 2,798 subjects 18–89 years of age who experienced a validated incident VT between January 1, 2002 and December 31, 2010, for a first recurrent VT, validated by medical record review. During follow-up, 457 (16%) developed a first recurrent VT. In time-to-event models incorporating time-varying statin use and adjusting for potential confounders, current statin use was associated with a 26% lower risk of recurrent VT: HR=0.74; 95%CI: 0.59–0.94. Among cohort members free of CVD (n=2,134), current statin use was also associated with a lower risk (38%) of recurrent VT: HR=0.62; 95%CI: 0.45–0.85. We found similar results when restricting to new users of statins and in subgroups of different statin types and doses. Conclusions In a population-based cohort of subjects who had experienced an incident VT, statin use, compared with non-use, was associated with a clinically-relevant lower risk of recurrent VT. These findings suggest a potential secondary benefit of statins among patients who have experienced an incident VT. PMID:27061794
Lung and chest wall impedances in the dog: effects of frequency and tidal volume.
Barnas, G M; Stamenović, D; Lutchen, K R; Mackenzie, C F
1992-01-01
Dependences of the mechanical properties of the respiratory system on frequency (f) and tidal volume (VT) in the normal ranges of breathing are not clear. We measured, simultaneously and in vivo, resistance and elastance of the total respiratory system (Rrs and Ers), lungs (RL and EL), and chest wall (Rcw and Ecw) of five healthy anesthetized paralyzed dogs during sinusoidal volume oscillations at the trachea (50-300 ml, 0.2-2 Hz) delivered at a constant mean lung volume. Each dog showed the same f and VT dependences. The Ers and Ecw increased with increasing f to 1 Hz and decreased with increasing VT up to 200 ml. Although EL increased slightly with increasing f, it was independent of VT. The Rcw decreased from 0.2 to 2 Hz at all VT and decreased with increasing VT. Although the RL decreased from 0.2 to 0.6 Hz and was independent of VT, at higher f RL tended to increase with increasing f and VT (i.e., as peak flow increased). Finally, the f and VT dependences of Rrs were similar to those of Rcw below 0.6 Hz but mirrored RL at higher f. These data capture the competing influences of airflow nonlinearities vs. tissue nonlinearities on f and VT dependence of the lung, chest wall, and total respiratory system. More specifically, we conclude that 1) VT dependences in Ers and Rrs below 0.6 Hz are due to nonlinearities in chest wall properties, 2) above 0.6 Hz, the flow dependence of airways resistance dominates RL and Rrs, and 3) lung tissue behavior is linear in the normal range of breathing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cuneo, M.E.; Hanson, D.L.; Menge, P.R.
SABRE (Sandia Accelerator and Beam Research Experiment) is a ten-cavity linear induction magnetically insulated voltage adder (6 MV, 300 kA) operated in positive polarity to investigate issues relevant to ion beam production and propagation for inertial confinement fusion. The voltage adder section is coupled to an applied-B extraction ion diode via a long coaxial output transmission line. Observations indicate that the power propagates in a vacuum wave prior to electron emission. After the electron emission threshold is reached, power propagates in a magnetically insulated wave. The precursor is observed to have a dominant impact on he turn-on, impedance history, andmore » beam characteristics of applied-B ion diodes since the precursor voltage is large enough to cause electron emission at the diode from both the cathode feed and cathode tips. The amplitude of the precursor at the load (3--4.5 MV) is a significant fraction of the maximum load voltage (5--6 MV) because (1) the transmission line gaps ( {approx} 9 cm at output) and therefore impedances are relatively large, and hence the electric field threshold for electron emission (200 to 300 kV/cm) is not reached until well into the power pulse rise time; and (2) the rapidly falling forward wave and diode impedance reduces the ratio of main pulse voltage to precursor voltage. Experimental voltage and current data from the transmission line and the ion diode will be presented and compared with TWOQUICK (2-D electromagnetic PIC code) simulations and analytic models.« less
Volume versus wiring transmission in the brain: a new theoretical frame for neuropsychopharmacology.
Agnati, L F; Bjelke, B; Fuxe, K
1995-01-01
A volume transmission mode of communication in brain was implicit already in the early work of Golgi, who postulated the existence of electrical signals in the extracellular fluid (ECF) based on Volta's "wet conductor" made by solutions. The term volume transmission is taken from the term volume conduction describing the flow of ionic currents in the ECF as a basis for the electrocorticogram. The slow VT mode includes also chemical signals and is opposed to the fast synaptic (wiring) transmission. Every neuron may function in a dual mode, the synaptic and the volume transmission mode, when considering the autocrine and synaptic classes of communication. The paracrine- and neuroendocrine-like classes only involve the VT mode in the latter case including the CSF as a route. The chemical signals for VT are the neuropeptides, but also the classical transmitters, the monoamines, acetylcholine, GABA, and glutamate can participate, when they operate via slow, high affinity G protein coupled receptors. Ions such as K+, Ca++, and H+ also function as VT signals. The hypothesis is also introduced that CO2 can act as a multifacit long-distance VT and WT regulator besides being part of the CO2/HCO3 buffer. CO2 via regulating NMDA receptor sensitivity can also regulate NO formation, which represents a paracrine and fast VT signal. The therapy of CNS disorders is also discussed in the frame of the wiring and VT concept. Two therapeutical approaches can therefore be developed, one based on increasing WT and one based on increasing VT. In contrast to the WT therapy, which must preserve the electrotemporal code, the VT therapy can operate also with postsynaptic agonists. Therefore, a therapeutic effect with such a drug indicates that the deficiency in the communication process operates via VT. In view of the lack of very effective negative feedbacks in VT vs. WT, VT therapy may produce less tolerance and drug dependency.
Predictors of new malignant ventricular arrhythmias after coronary surgery: a case-control study.
Ascione, Raimondo; Reeves, Barnaby C; Santo, Kirkpatrick; Khan, Nouman; Angelini, Gianni D
2004-05-05
We sought to investigate the relationship between perioperative factors and the occurrence of ventricular tachycardia (VT) and ventricular fibrillation (VF), as well as the impact of VT/VF on early and late mortality. Both VT and VF are rare but serious complications after coronary artery bypass graft surgery (CABG), and their etiology and implications remain uncertain. Data on 4,411 consecutive patients undergoing CABG (1,154 [25.8%] had off-pump surgery) between April 1996 and September 2001 were extracted from a prospective database and analyzed. Odds ratios (ORs) describing associations between possible risk factors and VT/VF were estimated separately. Factors observed to be significantly associated with VT/VF were further investigated using multivariate logistic regression. Sixty-nine patients suffered VT/VF (1.6%). There were 61 (1.4%) in-hospital/30-day deaths, 15 among patients who had postoperative VT/VF (21.7%). Patient factors independently associated with an increase in the odds of VT/VF included age <65 years, female gender, body mass index <25 kg/m(2), unstable angina, moderate or poor ejection fraction, and the need for inotropes and an intra-aortic balloon pump (OR 1.72 to 4.47, p < 0.05). After adjustment, off-pump surgery was associated with a substantial but nonsignificant protective effect against VT/VF (OR 0.53, 95% confidence interval [CI] 0.25 to 1.13; p = 0.10). Actuarial survival at two years was 98.2% among patients who had VT/VF and who survived to discharge/30 days, compared with 97.0% for the control group (adjusted hazard ratio 0.96 (95% CI 0.40 to 2.31, p = 0.92). The incidence of VT/VF is low in patients undergoing coronary surgery but is associated with high in-hospital mortality. The late survival of the discharged VT/VF patients compares favorably with that of controls.
Delécrin, Joël; Allain, Jérôme; Beaurain, Jacques; Steib, Jean-Paul; Chataigner, Hervé; Aubourg, Lucie; Huppert, Jean; Ameil, Marc; Nguyen, Jean-Michel
2009-01-01
Background An artificial disc prosthesis is thought to restore segmental motion in the lumbar spine. However, it is reported that disc prosthesis can increase the intervertebral translation (VT). The concept of the mobile-core prosthesis is to mimic the kinematic effects of the migration of the natural nucleus and therefore core mobility should minimize the VT. This study explored the hypothesis that core translation should influence VT and that a mobile core prosthesis may facilitate physiological motion. Methods Vertebral translation (measured with a new method presented here), core translation, range of motion (ROM), and distribution of flexion-extension were measured on flexion-extension, neutral standing, and lateral bending films in 89 patients (63 mobile-core [M]; 33 fixed-core [F]). Results At L4-5 levels the VT with M was lower than with F and similar to the VT of untreated levels. At L5-S1 levels the VT with M was lower than with F but was significantly different compared to untreated levels. At M levels a strong correlation was found between VT and core translation; the VT decreases as the core translation increases. At F levels the VT increases as the ROM increases. No significant difference was found between the ROM of untreated levels and levels implanted with either M or F. Regarding the mobility distribution with M and F we observed a deficit in extension at L5-S1 levels and a similar distribution at L4-5 levels compared to untreated levels. Conclusion The intervertebral mobility was different between M and F. The M at L4-5 levels succeeded to replicate mobility similar to L4-5 untreated levels. The M at L5-S1 succeeded in ROM, but failed regarding VT and mobility distribution. Nevertheless M minimized VT at L5-S1 levels. The F increased VT at both L4-5 and L5-S1. Clinical Relevance This study validates the concept that the core translation of an artificial lumbar disc prosthesis minimizes the VT. PMID:25802632
NASA Astrophysics Data System (ADS)
Kim, Hunho; Kwack, Young-Jin; Yun, Eui-Jung; Choi, Woon-Seop
2016-09-01
Solution-processed gate dielectrics were fabricated with the combined ZrO2 and Al2O3 (ZAO) in the form of mixed and stacked types for oxide thin film transistors (TFTs). ZAO thin films prepared with double coatings for solid gate dielectrics were characterized by analytical tools. For the first time, the capacitance of the oxide semiconductor was extracted from the capacitance-voltage properties of the zinc-tin oxide (ZTO) TFTs with the combined ZAO dielectrics by using the proposed metal-insulator-semiconductor (MIS) structure model. The capacitance evolution of the semiconductor from the TFT model structure described well the threshold voltage shift observed in the ZTO TFT with the ZAO (1:2) gate dielectric. The electrical properties of the ZTO TFT with a ZAO (1:2) gate dielectric showed low voltage driving with a field effect mobility of 37.01 cm2/Vs, a threshold voltage of 2.00 V, an on-to-off current ratio of 1.46 × 105, and a subthreshold slope of 0.10 V/dec.
NASA Astrophysics Data System (ADS)
Chou, Kuan-Yu; Hsu, Nai-Wen; Su, Yi-Hsin; Chou, Chung-Tao; Chiu, Po-Yuan; Chuang, Yen; Li, Jiun-Yun
2018-02-01
We investigate DC characteristics of a two-dimensional electron gas (2DEG) in an undoped Si/SiGe heterostructure and its temperature dependence. An insulated-gate field-effect transistor was fabricated, and transfer characteristics were measured at 4 K-300 K. At low temperatures (T < 45 K), source electrons are injected into the buried 2DEG channel first and drain current increases with the gate voltage. By increasing the gate voltage further, the current saturates followed by a negative transconductance observed, which can be attributed to electron tunneling from the buried channel to the surface channel. Finally, the drain current is saturated again at large gate biases due to parallel conduction of buried and surface channels. By increasing the temperature, an abrupt increase in threshold voltage is observed at T ˜ 45 K and it is speculated that negatively charged impurities at the Al2O3/Si interface are responsible for the threshold voltage shift. At T > 45 K, the current saturation and negative transconductance disappear and the device acts as a normal transistor.
Kim, Hunho; Kwack, Young-Jin; Yun, Eui-Jung; Choi, Woon-Seop
2016-01-01
Solution-processed gate dielectrics were fabricated with the combined ZrO2 and Al2O3 (ZAO) in the form of mixed and stacked types for oxide thin film transistors (TFTs). ZAO thin films prepared with double coatings for solid gate dielectrics were characterized by analytical tools. For the first time, the capacitance of the oxide semiconductor was extracted from the capacitance-voltage properties of the zinc-tin oxide (ZTO) TFTs with the combined ZAO dielectrics by using the proposed metal-insulator-semiconductor (MIS) structure model. The capacitance evolution of the semiconductor from the TFT model structure described well the threshold voltage shift observed in the ZTO TFT with the ZAO (1:2) gate dielectric. The electrical properties of the ZTO TFT with a ZAO (1:2) gate dielectric showed low voltage driving with a field effect mobility of 37.01 cm2/Vs, a threshold voltage of 2.00 V, an on-to-off current ratio of 1.46 × 105, and a subthreshold slope of 0.10 V/dec. PMID:27641430
NASA Astrophysics Data System (ADS)
Han, Chang-Wook; Han, Min-Koo; Choi, Nack-Bong; Kim, Chang-Dong; Kim, Ki-Yong; Chung, In-Jae
2007-07-01
Hydrogenated amorphous silicon (a-Si:H) thin-film transistors (TFTs) were fabricated on a flexible stainless-steel (SS) substrate. The stability of the a-Si:H TFT is a key issue for active matrix organic light-emitting diodes (AMOLEDs). The drain current decreases because of the threshold voltage shift (Δ VTH) during OLED driving. A negative voltage at a floated gate can be induced by a negative substrate bias through a capacitor between the substrate and the gate electrode without additional circuits. The negative voltage biased at the SS substrate can recover Δ VTH and reduced drain current of the driving TFT. The VTH of the TFT increased by 2.3 V under a gate bias of +15 V and a drain bias of +15 V at 65 °C applied for 3,500 s. The VTH decreased by -2.3 V and the drain current recovered 97% of its initial value under a substrate bias of -23 V at 65 °C applied for 3,500 s.
Method and system for controlling a synchronous machine over full operating range
Walters, James E.; Gunawan, Fani S.; Xue, Yanhong
2002-01-01
System and method for controlling a synchronous machine are provided. The method allows for calculating a stator voltage index. The method further allows for relating the magnitude of the stator voltage index against a threshold voltage value. An offset signal is generated based on the results of the relating step. A respective state of operation of the machine is determined. The offset signal is processed based on the respective state of the machine.
Threshold Voltage Instability in A-Si:H TFTS and the Implications for Flexible Displays and Circuits
2008-12-01
and negative gate voltages with and without elevated drain voltages for FDC TFTs. Extending techniques used to localize hot electron degradation...in MOSFETs, experiments in our lab have localized the degradation of a-Si:H to the gate dielectric/a-Si:H channel interface [Shringarpure, et al...saturation, increased drain source current measured with the source and drain reversed indicates localization of ΔVth to the gate dielectric/amorphous
Solntseva, E I; Bukanova, J V; Ostrovskaya, R U; Gudasheva, T A; Voronina, T A; Skrebitsky, V G
1997-07-01
1. With the use of the two-microelectrode voltage-clamp method, three types of voltage-activated ionic currents were examined in isolated neurons of the snail Helix pomatia: high-threshold Ca2+ current (ICa), high-threshold Ca(2+)-dependent K+ current (IK(Ca)) and high-threshold K+ current independent of Ca2+ (IK(V)). 2. The effect of bath application of the nootropics piracetam and a novel piracetam peptide analog, ethyl ester of N-phenyl-acetyl-L-prolyl-glycine (GVS-111), on these three types of voltage-activated ionic currents was studied. 3. In more than half of the tested cells, ICa was resistant to both piracetam and GVS-111. In the rest of the cells, ICa decreased 19 +/- 7% with 2 mM of piracetam and 39 +/- 14% with 2 microM of GVS-111. 4. IK(V) in almost all cells tested was resistant to piracetam at concentrations up to 2 mM. However, IK(V) in two-thirds of the cells was sensitive to GVS-111, being suppressed 49 +/- 18% with 1 microM GVS-111. 5. IK(Ca) appeared to be the most sensitive current of those studied to both piracetam and GVS-111. Piracetam at 1 mM and GVS-111 at 0.1 microM decreased the amplitude of IK(Ca) in most of the cells examined by 49 +/- 19% and 69 +/- 24%, respectively. 6. The results suggest that piracetam and GVS-111 suppression of voltage-activated calcium and potassium currents of the neuronal membrane may regulate (both up and down) Ca2+ influx into neurons.
NASA Astrophysics Data System (ADS)
Hsu, M. K.; Chiu, S. Y.; Wu, C. H.; Guo, D. F.; Lour, W. S.
2008-12-01
Pseudomorphic Al0.22Ga0.78As/In0.16Ga0.84As/Al0.22Ga0.78As double heterojunction high electron mobility transistors (DH-HEMTs) fabricated with different gate-formation structures of a single-recess gate (SRG), a double-recess gate (DRG) and a field-plate gate (FPG) were comparatively investigated. FPG devices show the best breakdown characteristics among these devices due to great reduction in the peak electric field between the drain and gate electrodes. The measured gate-drain breakdown voltages defined at a 1 mA mm-1 reverse gate-drain current density were -15.3, -19.1 and -26.0 V for SRG, DRG and FPG devices, respectively. No significant differences in their room-temperature common-source current-voltage characteristics were observed. However, FPG devices exhibit threshold voltages being the least sensitive to temperature. Threshold voltages as a function of temperature indicate a threshold-voltage variation as low as -0.97 mV K-1 for FPG devices. According to the 2.4 GHz load-pull power measurement at VDS = 3.0 V and VGS = -0.5 V, the saturated output power (POUT), power gain (GP) and maximum power-added efficiency (PAE) were 10.3 dBm/13.2 dB/36.6%, 11.2 dBm/13.1 dB/39.7% and 13.06 dBm/12.8 dB/47.3%, respectively, for SRG, DRG and FPG devices with a pi-gate in class AB operation. When the FPG device is biased at a VDS of 10 V, the saturated power density is more than 600 mW mm-1.
Badenhorst, Werner; Hanekom, Tania; Hanekom, Johan J
2016-12-01
This study presents the development of an alternative noise current term and novel voltage-dependent current noise algorithm for conductance-based stochastic auditory nerve fibre (ANF) models. ANFs are known to have significant variance in threshold stimulus which affects temporal characteristics such as latency. This variance is primarily caused by the stochastic behaviour or microscopic fluctuations of the node of Ranvier's voltage-dependent sodium channels of which the intensity is a function of membrane voltage. Though easy to implement and low in computational cost, existing current noise models have two deficiencies: it is independent of membrane voltage, and it is unable to inherently determine the noise intensity required to produce in vivo measured discharge probability functions. The proposed algorithm overcomes these deficiencies while maintaining its low computational cost and ease of implementation compared to other conductance and Markovian-based stochastic models. The algorithm is applied to a Hodgkin-Huxley-based compartmental cat ANF model and validated via comparison of the threshold probability and latency distributions to measured cat ANF data. Simulation results show the algorithm's adherence to in vivo stochastic fibre characteristics such as an exponential relationship between the membrane noise and transmembrane voltage, a negative linear relationship between the log of the relative spread of the discharge probability and the log of the fibre diameter and a decrease in latency with an increase in stimulus intensity.
NASA Astrophysics Data System (ADS)
Shian, Samuel; Kjeer, Peter; Clarke, David R.
2018-03-01
When a voltage is applied to a percolative, mechanically compliant mat of carbon nanotubes (CNTs) on a smooth elastomer bilayer attached to an ITO coated glass substrate, the in-line optical transmittance decreases with increasing voltage. Two regimes of behavior have been identified based on optical scattering, bright field optical microscopy, and confocal optical microscopy. In the low field regime, the electric field produces a spatially inhomogeneous surface deformation of the elastomer that causes local variations in optical refraction and modulates the light transmittance. The spatial variation is associated with the distribution of the CNTs over the surface. At higher fields, above a threshold voltage, an array of pits in the surface form by a nucleation and growth mechanism and these also scatter light. The formation of pits, and creases, in the thickness of the elastomer, is due to a previously identified electro-mechanical surface instability. When the applied voltage is decreased from its maximum, the transmittance returns to its original value although there is a transmittance hysteresis and a complicated time response. When the applied voltage exceeds the threshold voltage, there can be remnant optical contrast associated with creasing of the elastomer and the recovery time appears to be dependent on local jamming of CNTs in areas where the pits formed. A potential application of this work as an electrically tunable privacy window or camouflaging devices is demonstrated.
Lactate Threshold as a Measure of Aerobic Metabolism in Resistance Exercise.
Domínguez, Raúl; Maté-Muñoz, José Luis; Serra-Paya, Noemí; Garnacho-Castaño, Manuel Vicente
2018-02-01
In resistance training, load intensity is usually calculated as the percentage of a maximum repetition (1RM) or maximum number of possible repetitions (% of 1RM). Some studies have proposed a lactate threshold (LT) intensity as an optimal approach for concurrent training of cardiorespiratory endurance and muscle strength, as well as an alternative in resistance training. The objective of the present study was to analyze the results obtained in research evaluating the use of LT in resistance training. A keyword and search tree strategy identified 14 relevant articles in the Dialnet, Elsevier, Medline, Pubmed, Scopus and Web of Science databases. Based on the studies analyzed, the conclusion was that the LT in resistance exercises can be determined either by mathematical methods or by visual inspection of graphical plots. Another possibility is to measure the intensity at which LT might coincide with the first ventilatory threshold (VT1). Since performing an exercise session at one's LT intensity has been shown to accelerate the cardiorespiratory response and induce neuromuscular fatigue, this intensity could be used to set the training load in a resistance training program. © Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
Mookerjea, Saurabh A.
Over the past decade the microprocessor clock frequency has hit a plateau. The main reason for this has been the inability to follow constant electric field scaling, which requires the transistor supply voltage to be scaled down as the transistor dimensions are reduced. Scaling the supply voltage down reduces the dynamic power quadratically but increases the static leakage power exponentially due to non-scalability of threshold voltage of the transistor, which is required to maintain the same ON state performance. This limitation in supply voltage scaling is directly related to MOSFET's (Metal Oxide Semiconductor Field Effect Transistor) sub-threshold slope (SS) limitation of 60 mV/dec at room temperature. Thus novel device design/materials are required that would allow the transistor to switch with sub-threshold slopes steeper than 60 mV/dec at room temperature, thus facilitating supply voltage scaling. Recently, a new class of devices known as super-steep slope (SS<60 mV/dec) transistors are under intense research for its potential to replace the ubiquitous MOSFET. The focus of this dissertation is on the design, fabrication and characterization of band-to-band tunneling field effect transistor (TFET) which belongs to the family of steep slope transistors. TFET with a gate modulated zener tunnel junction at the source allows sub-kT/q (sub-60 mV/dec at room temperature) sub-threshold slope (SS) device operation over a certain gate bias range near the off-state. This allows TFET to achieve much higher I ON-IOFF ratio over a specified gate voltage swing compared to MOSFETs, thus enabling aggressive supply voltage scaling for low power logic operation without impacting its ON-OFF current ratio. This dissertation presents the operating principle of TFET, the material selection strategy and device design for TFET fabrication. This is followed by a novel 6T SRAM design which circumvents the issue of unidirectional conduction in TFET. The switching behavior of TFET is studied through mixed-mode numerical simulations. The significance of correct benchmarking methodology to estimate the effective drive current and capacitance in TFET is highlighted and compared with MOSFET. This is followed by the fabrication details of homo-junction TFET. Analysis of the electrical characteristics of homo-junction TFET gives key insight into its device operation and identifies the critical factors that impact its performance. In order to boost the ON current, the design and fabrication of hetero-junction TFET is also presented.
NASA Astrophysics Data System (ADS)
Goo, Yong Sook; Ye, Jang Hee; Lee, Seokyoung; Nam, Yoonkey; Ryu, Sang Baek; Kim, Kyung Hwan
2011-06-01
Retinal prostheses are being developed to restore vision for those with retinal diseases such as retinitis pigmentosa or age-related macular degeneration. Since neural prostheses depend upon electrical stimulation to control neural activity, optimal stimulation parameters for successful encoding of visual information are one of the most important requirements to enable visual perception. In this paper, we focused on retinal ganglion cell (RGC) responses to different stimulation parameters and compared threshold charge densities in wild-type and rd1 mice. For this purpose, we used in vitro retinal preparations of wild-type and rd1 mice. When the neural network was stimulated with voltage- and current-controlled pulses, RGCs from both wild-type and rd1 mice responded; however the temporal pattern of RGC response is very different. In wild-type RGCs, a single peak within 100 ms appears, while multiple peaks (approximately four peaks) with ~10 Hz rhythm within 400 ms appear in RGCs in the degenerated retina of rd1 mice. We find that an anodic phase-first biphasic voltage-controlled pulse is more efficient for stimulation than a biphasic current-controlled pulse based on lower threshold charge density. The threshold charge densities for activation of RGCs both with voltage- and current-controlled pulses are overall more elevated for the rd1 mouse than the wild-type mouse. Here, we propose the stimulus range for wild-type and rd1 retinas when the optimal modulation of a RGC response is possible.
Ji, G E; Park, S Y; Wong, S S; Pestka, J J
1998-02-06
Characterization of how vomitoxin (VT) and other trichothecenes affect macrophage regulatory and effector function may contribute to improved understanding of mechanisms by which these mycotoxins impact the immune system. The RAW 264.7 murine cell line was used as a macrophage model to assess effects of the VT on proliferation and the production of nitric oxide (NO), hydrogen peroxide (H2O2) and cytokines. Using the MTT cleavage assay, VT at concentrations of 50 ng/ml or higher was found to significantly decrease proliferation and viability of RAW 264.7 cells without stimulation or with stimulation by lipopolysaccharide (LPS) or interferon (IFN)-gamma. In the absence of an activation agent, VT (25-250 ng/ml) had negligible effects on the production of NO, H2O2, and cytokines. Upon activation with LPS at concentrations of 10 to 100 ng/ml, VT at 25-100 ng/ml markedly enhanced production of H2O2 but was inhibitory at 250 ng/ml. VT enhancement of H2O2 production was observed as early as 12 h after LPS stimulation. When IFN-gamma was used as the stimulant, VT (25-250 ng/ml) delayed peak H2O2 production. VT (25-250 ng/ml) also markedly decreased NO production in cells activated with LPS or IFN-gamma. Interestingly, VT superinduced TNF-alpha and IL-6 production in LPS-stimulated cells and also elevated TNF-alpha in IFN-gamma stimulated cells. These results suggest that VT can selectively and concurrently upregulate or downregulate critical functions associated with activated macrophages.
Herholz, C; Straub, R; Gerber, V; Wampfler, B; Lüthi, S; Imhof, A; Moens, Y; Busato, A
2002-03-01
The pulmonary health of 66 horses was assessed by a clinical examination and simple supplementary diagnostic methods. Single breath diagrams for CO(2) (SBD-CO(2)) and derived lung function indices were used to determine pulmonary function. The clinical signs in different groups were related to the results of the lung function indices derived from the SBD-CO(2). In horses with moderate to severe chronic obstructive pulmonary disease (COPD), a significant relationship was found between the respiratory frequency and the ratio of Bohr's dead space to the tidal volume (VD(Bohr)/VT), and between the physiological dead space/tidal volume ratio (VD(phys)/VT) and the ratio of the alveolar dead space to the alveolar tidal volume (VD(alv)/VT(alv)), but no significant associations were found between the arterial oxygen tension (P(a)O(2)) and lung function indices derived from the SBD-CO(2). The occurrence of cough, the viscosity of tracheobronchial mucus and the amount of polynuclear neutrophils in tracheobronchial aspirates were significantly related to the expiratory tidal volume (VT), the total expired volume of CO(2) (VCO(2)), VD(Bohr)/VT, VD(phys)/VT and VD(alv)/VT(alv). We conclude that abnormal findings in these clinical parameters indicate a measurable ventilation and perfusion (V(A)/Q) mismatch which is reflected by increases in dead space, VD(Bohr)/VT and VD(phys)/VT as well as VD(alv)/VT(alv). Copyright 2002 Elsevier Science Ltd. All rights reserved.
Murata, Hiroshige; Miyauchi, Yasushi; Hayashi, Meiso; Iwasaki, Yu-Ki; Yodogawa, Kenji; Ueno, Akira; Hayashi, Hiroshi; Tsuboi, Ippei; Uetake, Shunsuke; Takahashi, Kenta; Yamamoto, Teppei; Maruyama, Mitsunori; Akutsu, Koichi; Yamamoto, Takeshi; Kobayashi, Yoshinori; Tanaka, Keiji; Atarashi, Hirotsugu; Katoh, Takao; Shimizu, Wataru
2015-01-01
Few reports are available on the characteristics of electrical storms of ventricular tachycardia (VT storm) refractory to intravenous (IV) amiodarone. IV-amiodarone was administered to 60 patients with ventricular tachyarrhythmia between 2007 and 2012. VT storms, defined as 3 or more episodes of VT within 24 h, occurred in 30 patients (68±12 years, 7 female), with 12 having ischemic and 18 non-ischemic heart disease. We compared the clinical and electrocardiographic characteristics of the patients with VT storms suppressed by IV-amiodarone (Effective group) to those of patients not affected by the treatment (Refractory group). IV-amiodarone could not control recurrence of VT in 9 patients (30%). The Refractory group comprised 5 patients with acute myocardial infarctions. Although there was no difference in the VT cycle length, the QRS duration of both the VT and premature ventricular contractions (PVCs) followed by VT was narrower in the Refractory group than in the Effective group (140±30 vs. 178±25 ms, P<0.01; 121±14 vs. 179±22 ms, P<0.01). In the Refractory group, additional administration of IV-mexiletine and/or Purkinje potential-guided catheter ablation was effective. IV-amiodarone-refractory VT exhibited a relatively narrow QRS tachycardia. The narrow triggering PVCs, suggesting a Purkinje fiber origin, may be treated by additional IV-mexiletine and endocardial catheter ablation.
Vantage Theory and Linguistic Relativity
ERIC Educational Resources Information Center
Allan, Keith
2010-01-01
Rob MacLaury's Vantage Theory, VT, models the way in which a cognizer constructs, recalls, uses, and modifies a category in terms of point of view or vantage. Alongside of VT, there is place for the kind of semantic specification found in the lexicon. VT2 [Allan, Keith, 2002. "Vantage theory, VT2, and number." "Language Sciences" 24(5-6), 679-703…
Mohsenifar, Z; Tashkin, D P; Levy, S E; Bjerke, R D; Clements, P J; Furst, D
1981-05-01
Wasted ventilation fraction (Vd/Vt) normally declines substantially during exercise in persons without lung disease. Failure of Vd/Vt to decrease during exercise has been reported to be one of the earliest abnormalities in patients with dyspnea caused by pulmonary vaso-occlusive disease, suggesting that measurement of Vd/Vt at rest and during exercise are useful in the diagnosis of pulmonary vascular disorders. We studied pulmonary hemodynamic and Vd/Vt responses to exercise in 11 patients in the supine position with suspected pulmonary vascular involvement caused by progressive systemic sclerosis, systemic lupus erythematosus, or recurrent pulmonary emboli, 10 of whom had dyspnea at rest and/or on exertion. In contrast to previous reports of no change or an increase in Vd/Vt during exercise in patients with pulmonary vascular disease, we found Vd/Vt to decrease significantly during exercise in 8 of 9 patients in whom mean pulmonary artery pressures were abnormally elevated at rest and/or during exercise. Our findings suggest that normal responses of Vd/Vt to exercise do not exclude hemodynamically significant pulmonary vaso-occlusive disease.
NASA Astrophysics Data System (ADS)
Kim, Youngjun; Ko, Hyungduk; Park, Byoungnam
2018-04-01
Nanocrystal (NC) size and ligand dependent dynamic trap formation of lead sulfide (PbS) NCs in contact with an organic semiconductor were investigated using a pentacene/PbS field effect transistor (FET). We used a bilayer pentacene/PbS FET to extract information of the surface traps of PbS NCs at the pentacene/PbS interface through the field effect-induced charge carrier density measurement in the threshold and subthreshold regions. PbS size and ligand dependent trap properties were elucidated by the time domain and threshold voltage measurements in which threshold voltage shift occurs by carrier charging and discharging in the trap states of PbS NCs. The observed threshold voltage shift is interpreted in context of electron trapping through dynamic trap formation associated with PbS NCs. To the best of our knowledge, this is the first demonstration of the presence of interfacial dynamic trap density of PbS NC in contact with an organic semiconductor (pentacene). We found that the dynamic trap density of the PbS NC is size dependent and the carrier residence time in the specific trap sites is more sensitive to NC size variation than to NC ligand exchange. The probing method presented in the study offers a means to investigate the interfacial surface traps at the organic-inorganic hetero-junction, otherwise understanding of the buried surface traps at the functional interface would be elusive.
Instability of phosphorous doped SiO2 in 4H-SiC MOS capacitors at high temperatures
NASA Astrophysics Data System (ADS)
Idris, M. I.; Weng, M. H.; Chan, H.-K.; Murphy, A. E.; Clark, D. T.; Young, R. A. R.; Ramsay, E. P.; Wright, N. G.; Horsfall, A. B.
2016-12-01
In this paper, the effect of inclusion of phosphorous (at a concentration below 1%) on the high temperature characteristics (up to 300 °C) of the SiO2/SiC interface is investigated. Capacitance-voltage measurements taken for a range of frequencies have been utilized to extract parameters including flatband voltage, threshold voltage, effective oxide charge, and interface state density. The variation of these parameters with temperature has been investigated for bias sweeps in opposing directions and a comparison made between phosphorous doped and as-grown oxides. At room temperature, the effective oxide charge for SiO2 may be reduced by the phosphorous termination of dangling bonds at the interface. However, at high temperatures, the effective charge in the phosphorous doped oxide remains unstable and effects such as flatband voltage shift and threshold voltage shift dominate the characteristics. The instability in these characteristics was found to result from the trapped charges in the oxide (±1012 cm-3) or near interface traps at the interface of the gate oxide and the semiconductor (1012-1013 cm-2 eV-1). Hence, the performance enhancements observed for phosphorous doped oxides are not realised in devices operated at elevated temperatures.
Characterization of Thermal Refugia and Biogeochemical Hotspots at Sleepers River Watershed, VT
NASA Astrophysics Data System (ADS)
Hwang, K.; Chandler, D. G.; Kelleher, C.; Shanley, J. B.; Shaw, S. B.
2017-12-01
During low flow, changes in the extent of the channel network in headwater catchments depend on groundwater-surface water interactions, and dictate thermal and biogeochemical heterogeneities. Channel reaches with low temperature may act as refugia for valued species such as brook trout, and warmer reaches with high dissolved organic matter may act as biogeochemical hotspots. Prior studies have found uniform scaling of hydrologic and biogeochemical processes above certain spatial thresholds but sizable heterogeneities in these processes below the threshold. We utilize high resolution measurements of water quality parameters including stream temperature, conductivity and fluorescent dissolved organic matter (fDOM) at tributaries in two catchments of Sleepers River Watershed, Vermont to investigate seasonal and spatial variation of water quality and scaling of stream chemistry within the intensive study area and the larger Sleepers River Watershed. This study leverages findings from various small scale regional studies to identify differences in headwater channel reach behavior in a similar climate across some dissimilar geomorphic units, to inform the identification of thermal refugia and biogeochemical hotspots.
Over-voltage protection system and method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chi, Song; Dong, Dong; Lai, Rixin
An over-voltage protection system includes an electronic valve connected across two terminals of a circuit and an over-voltage detection circuit connected across one of the plurality of semiconductor devices for detecting an over-voltage across the circuit. The electronic valve includes a plurality of semiconductor devices connected in series. The over-voltage detection circuit includes a voltage divider circuit connected to a break-over diode in a way to provide a representative low voltage to the break-over diode and an optocoupler configured to receive a current from the break-over diode when the representative low voltage exceeds a threshold voltage of the break-over diodemore » indicating an over-voltage condition. The representative low voltage provided to the break-over diode represents a voltage across the one semiconductor device. A plurality of self-powered gate drive circuits are connected to the plurality of semiconductor devices, wherein the plurality of self-powered gate drive circuits receive over-voltage triggering pulses from the optocoupler during the over-voltage condition and switch on the plurality of semiconductor devices to bypass the circuit.« less
Paradigm shift in lead design.
Irnich, W
1999-09-01
During the past 30 years there has been a tremendous development in electrode technology from bulky (90 mm2) to pin-sized (1.0 mm2) electrodes. Simultaneously, impedance has increased from 110 Ohms to >1 kOhms, which has been termed a "paradigm shift" in lead design. If current is responsible for stimulation, why is its impedance a key factor in saving energy? Further, what mechanism is behind this development based on experimental findings and what conclusion can be drawn from it to optimize electrode size? If it is assumed that there is always a layer of nonexcitable tissue between the electrode surface and excitable myocardium and that the electric field (potential gradient) produced by the electrode at this boundary is reaching threshold level, then a formula can be derived for the voltage threshold that completely describes the electrophysiology and electrophysics of a hemispherical electrode. Assuming that the mean chronic threshold for porous steroid-eluting electrodes is 0.6 V with 0.5-ms pulse duration, thickness of nonexcitable tissue can be estimated to be 1.5 mm. Taking into account this measure and the relationship between chronaxie and electrode area, voltage threshold, impedance, and energy as a function of surface area can be calculated. The lowest voltage for 0.5-ms pulse duration is reached with r(o) = 0.5 d, yielding a surface area of 4 mm2 and a voltage threshold of 0.62 V, an impedance of 1 kOhms, and an energy level of 197 nJ. It can be deduced from our findings that a further reduction of surface areas below 1.6 mm2 will not diminish energy threshold substantially, if pulse duration remains at 0.5 ms. Lowest energy is reached with t = chronaxie, yielding an energy level <100 nJ with surface areas < or =1.5 mm2. It is striking to see how well the theoretically derived results correspond to the experimental findings. It is also surprising that the hemispheric model so accurately approximates experimental results with differently shaped electrodes that it can be concluded that electrode shape seems to play a minor role in electrode efficiency. Further energy reduction can only be achieved by reducing the pulse duration to chronaxie. A real paradigm shift will occur only if the fundamentals of electrostimulation in combination with electrophysics are accepted by the pacing community.
The Rated Voltage Determination of DC Building Power Supply System Considering Human Beings Safety
NASA Astrophysics Data System (ADS)
Wang, Zhicheng; Yu, Kansheng; Xie, Guoqiang; Zou, Jin
2018-01-01
Generally two-level voltages are adopted for DC building power supply system. From the point of view of human beings safety, only the lower level voltage which may be contacted barehanded is discussed in this paper based on the related safety thresholds of human beings current effect. For several voltage levels below 100V recommended by IEC, the body current and current density of human electric shock under device normal work condition, as well as effect of unidirectional single impulse currents of short durations are calculated and analyzed respectively. Finally, DC 60V is recommended as the lower level rating voltage through the comprehensive consideration of technical condition and cost of safety criteria.
[Effect of airway humidification on lung injury induced by mechanical ventilation].
Song, Junjie; Jiang, Min; Qi, Guiyan; Xie, Yuying; Wang, Huaiquan; Tian, Yonggang; Qu, Jingdong; Zhang, Xiaoming; Li, Haibo
2014-12-01
To explore the effect of airway humidification on lung injury as a result of mechanical ventilation with different tidal volume (VT). Twenty-four male Japanese white rabbits were randomly divided into four groups: low VT with airway humidification group, high VT with airway humidification group, low VT and high VT group without humidification, with 6 rabbits in each group. Mechanical ventilation was started after intubation and lasted for 6 hours. Low VT denoted 8 mL/kg, while high VT was 16 mL/kg, fraction of inspired oxygen (FiO₂) denoted 0.40, positive end-expiratory pressure (PEEP) was 0. Temperature at Y piece of circuit in airway humidification groups was monitored and controlled at 40 centigrade. Arterial blood gas analysis, including pH value, arterial partial pressure of oxygen (PaO₂), arterial partial pressure of carbon dioxide (PaCO₂), lung mechanics indexes, including peak airway pressure (P(peak)) and airway resistance (Raw), and lung compliance was measured at 0, 2, 4, 6 hours of mechanical ventilation. The levels of tumor necrosis factor-α (TNF-α) and interleukin-8 (IL-8) in plasma and bronchoalveolar lavage fluid (BALF) were determined by enzyme linked immunosorbent assay (ELISA). The animals were sacrificed at the end of mechanical ventilation. The wet to dry (W/D) ratio of lung tissues was calculated. Histopathologic changes in the lung tissueies were observed with microscope, and lung injury score was calculated. Scanning and transmission electron microscopies were used to examine the integrity of the airway cilia and the tracheal epithelium. Compared with low V(T) group, pH value in high V(T) group was significantly increased, PaCO₂was significantly lowered, and no difference in PaO₂was found. P(peak), Raw, and lung compliance were significantly increased during mechanical ventilation. There were no significant differences in blood gas analysis and lung mechanics indexes between low V(T) with airway humidification group and low V(T) group. Compared with high V(T) group, PaCO₂in high V(T) with airway humidification group was significantly decreased, Ppeak raised obviously, and no difference in pH value, PaO₂, Raw and pulmonary compliance was found. Compared with low V(T) with airway humidification group, no difference in blood gas analysis (PaCO2, mmHg, 1 mmHg=0.133 kPa) was found, but Ppeak (cmH₂O, 1 cmH₂O=0.098 kPa), Raw (cmH₂O), and lung compliance (mL/cmH₂O) were increased significantly in high V(T) with airway humidification group (PaCO₂at 2 hours: 27.96 ± 4.64 vs. 36.08 ± 2.11, 4 hours: 28.62 ± 2.93 vs. 34.55 ± 5.50, 6 hours: 29.33 ± 2.14 vs. 35.01 ± 5.53; Ppeak at 0 hour: 14.34 ± 1.97 vs. 8.84 ± 1.32, 2 hours: 17.33 ± 0.52 vs. 11.17 ± 2.14, 4 hours: 17.83 ± 0.98 vs. 12.67 ± 2.06, 6 hours: 18.67 ± 1.22 vs. 13.50 ± 2.16; Raw at 0 hour: 37.36 ± 5.14 vs. 27.0 5 ± 2.93, 2 hours: 43.94 ± 6.58 vs. 31.95 ± 3.56, 4 hours: 48.04 ± 6.07 vs. 35.24 ± 3.50, 6 hours: 50.33 ± 6.34 vs. 36.66 ± 3.64; pulmonary compliance at 6 hours: 2.28 ± 0.18 vs. 1.86 ± 0.37, all P<0.05). The lung W/D ratio in high VT group was significantly higher than that of the low V(T) group (6.17 ± 2.14 vs. 3.50 ± 1.52, P<0.05). W/D in high V(T) with airway humidification group was higher than that of low V(T) with airway humidification group but without statistically significant difference (5.17 ± 2.14 vs. 3.00 ± 1.10, P>0.05). Microscopic observation showed that cilia were partially detached, adhered and sparse in low V(T) group, while cilia in high V(T) group showed serious detachment and lodging. Remaining cilia were sparse, with lodging, and cellular structure was damaged. Lung tissue pathological injury score in the high V(T) group was significantly higher than that of low V(T) group (6.17 ± 2.14 vs. 3.50 ± 1.52, P<0.05). Cilia density and cellularity were normal in low V(T) with airway humidification group, and no difference in lung tissue pathological injury score was found compared with low V(T) group (3.00 ± 1.10 vs. 3.50 ± 1.52, P>0.05). Cilia were severely detached, adhered and lodging, and cellularity were not obvious in high V(T) with airway humidification group, and lung tissue pathological injury score was elevated significantly than that of the low V(T) with airway humidification group but without statistically significant difference (5.17 ± 2.14 vs. 3.00 ± 1.10, P>0.05). TNF-α and IL-8 concentrations showed no change in plasma and BALF in all groups during ventilation, and no significant difference was found among the groups. Airway humidification can alleviate pathological lung injury, damage of cilia and cellular structure in trachea caused by mechanical ventilation with low and high V(T). High V(T) with humidification can result in serious pulmonary edema.
Muser, Daniele; Liang, Jackson J; Pathak, Rajeev K; Magnani, Silvia; Castro, Simon A; Hayashi, Tatsuya; Garcia, Fermin C; Supple, Gregory E; Riley, Michael P; Lin, David; Dixit, Sanjay; Zado, Erica S; Frankel, David S; Callans, David J; Marchlinski, Francis E; Santangeli, Pasquale
2017-07-01
The goal of this study was to determine the long-term outcomes of catheter ablation (CA) of electrical storm in patients with nonischemic dilated cardiomyopathy (NIDCM) compared with patients with ischemic cardiomyopathy (ICM). CA of ventricular tachycardia (VT) electrical storm has been shown to improve VT-free survival in patients with ICM. Data on the outcomes of CA of electrical storm in patients with NIDCM are insufficient. The study included 267 consecutive patients with NIDCM (n = 71; ejection fraction 32 ± 14%) and ICM (n = 196; ejection fraction 28 ± 12%). Endo-epicardial CA was performed in 59 (22%) patients. CA was guided by activation and entrainment mapping for tolerated VT and pacemapping/targeting of abnormal substrate for unmappable VT. After a median follow-up of 45 (25th to 75th percentile: 9 to 71) months and 1 (25th to 75th percentile: 1 to 8) procedures, 76 (29%) patients died, 25 (9%) underwent heart transplantation, 87 (33%) experienced VT recurrence, and 13 (5%) had recurrence of electrical storm. Overall VT-free survival was 54% at 60 months (48% in NIDCM and 54% in ICM; p = 0.128). Patients with VT recurrence experienced a median of 2 (1 to 10) VT episodes in the 5 (1 to 14) months after the procedure. Death/transplantation-free survival was 62% at 60 months (53% in NIDCM and 64% in ICM; p = 0.067). Persistent inducibility of any VT with cycle length ≥250 ms at programmed stimulation at the end of the procedure was the only independent predictor of VT recurrence. Low ejection fraction, New York Heart Association functional class, and VT recurrence over follow-up independently predicted death/transplantation. CA of electrical storm was similarly effective in patients with NIDCM compared with patients with ICM, with elimination of electrical storm in 95% of cases and achievement of complete VT control at long-term follow-up in most patients. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Akhmedova, A. M.
2018-04-01
The behavior of an electronic subsystem is investigated in the course of formation and development of a memory channel in solid solutions of the TlInTe2-TlYbTe2 system. An analysis of the current-voltage characteristics allows getting an insight into the reason for a sharp change in electrical conductance of the specimens under study during their transition from the high-resistance to high-conductance state and the reasons for the well known instability of threshold converters, which makes it possible to design devices with high threshold voltage stability.
NASA Technical Reports Server (NTRS)
Kim, J. H.; Katz, J.; Lin, S. H.; Psaltis, D.
1989-01-01
A monolithic 10 x 10 two-dimensional array of 'optical neuron' optoelectronic threshold elements for neural network applications has been designed, fabricated, and tested. Overall array dimensions are 5 x 5 mm, while the individual neurons, composed of an LED that is driven by a double-heterojunction bipolar transistor, are 250 x 250 microns. The overall integrated structure exhibited semiconductor-controlled rectifier characteristics, with a breakover voltage of 75 V and a reverse-breakdown voltage of 60 V; this is attributable to the parasitic p-n-p transistor which exists as a result of the sharing of the same n-AlGaAs collector between the transistors and the LED.
Quantum Corrections to the 'Atomistic' MOSFET Simulations
NASA Technical Reports Server (NTRS)
Asenov, Asen; Slavcheva, G.; Kaya, S.; Balasubramaniam, R.
2000-01-01
We have introduced in a simple and efficient manner quantum mechanical corrections in our 3D 'atomistic' MOSFET simulator using the density gradient formalism. We have studied in comparison with classical simulations the effect of the quantum mechanical corrections on the simulation of random dopant induced threshold voltage fluctuations, the effect of the single charge trapping on interface states and the effect of the oxide thickness fluctuations in decanano MOSFETs with ultrathin gate oxides. The introduction of quantum corrections enhances the threshold voltage fluctuations but does not affect significantly the amplitude of the random telegraph noise associated with single carrier trapping. The importance of the quantum corrections for proper simulation of oxide thickness fluctuation effects has also been demonstrated.
Addressable inverter matrix for process and device characterization
NASA Technical Reports Server (NTRS)
Buehler, M. G.; Sayah, H. R.
1985-01-01
The addressable inverter matrix consists of 222 inverters each accessible with the aid of a shift register. The structure has proven useful in characterizing the variability of inverter transfer curves and in diagnosing processing faults. For good 3-micron CMOS bulk inverters investigated, the percent standard deviation of the inverter threshold voltage was less than one percent and the inverter gain (the slope of the inverter transfer curve at the inverter threshold vltage) was less than 3 percent. The average noise margin for the inverters was near 2 volts for a power supply voltage of 5 volts. The specific faults studied included undersize pull-down transistor widths and various open contacts in the matrix.
Liu, Wei; Zhang, Zhao-qin; Zhao, Xiao-min; Gao, Yun-sheng
2006-05-01
To investigate the effect of Uncaria rhynchophylla total alkaloids (RTA) pretreatment on the voltage-gated sodium currents of the rat hippocampal neurons after acute hypoxia. Primary cultured hippocampal neurons were divided into RTA pre-treated and non-pretreated groups. Patch clamp whole-cell recording was used to compare the voltage-gated sodium current amplitude and threshold with those before hypoxia. After acute hypoxia, sodium current amplitude was significantly decreased and its threshold was upside. RTA pretreatment could inhibit the reduction of sodium current amplitude. RTA pretreatment alleviates the acute hypoxia-induced change of sodium currents, which may be one of the mechanisms for protective effect of RTA on cells.
Vibration therapy in patients with cerebral palsy: a systematic review
Ritzmann, Ramona; Stark, Christina; Krause, Anne
2018-01-01
The neurological disorder cerebral palsy (CP) is caused by unprogressive lesions of the immature brain and affects movement, posture, and the musculoskeletal system. Vibration therapy (VT) is increasingly used to reduce the signs and symptoms associated with this developmental disability. The purpose of this narrative review was systematically to appraise published research regarding acute and long-term effects of VT on functional, neuromuscular, and structural parameters. Systematic searches of three electronic databases identified 28 studies that fulfilled the inclusion criteria. Studies were analyzed to determine participant characteristics, VT-treatment protocols, effect on gross motor function (GMF), strength, gait, posture, mobility, spasticity, reflex excitability, muscle tone, mass, and bone strength within this population, and outcome measures used to evaluate effects. The results revealed that one acute session of VT reduces reflex excitability, spasticity, and coordination deficits. Subsequently, VT has a positive effect on the ability to move, manifested for GMF, strength, gait, and mobility in patients with CP. Effects persist up to 30 minutes after VT. Long-term effects of VT manifest as reduced muscle tone and spasticity occurring concomitantly with improved movement ability in regard to GMF, strength, gait, and mobility, as well as increased muscle mass and bone-mineral density. Posture control remained unaffected by VT. In conclusion, the acute and chronic application of VT as a nonpharmacological approach has the potential to ameliorate CP symptoms, achieving functional and structural adaptations associated with significant improvements in daily living. Even though further studies including adult populations validating the neuromuscular mechanisms underlying the aforementioned adaptations should be fostered, growing scientific evidence supports the effectiveness of VT in regard to supplementing conventional treatments (physiotherapy and drugs). Therefore, VT could reduce CP-associated physical disability and sensorimotor handicaps. Goals for patients and their caregivers referring to greater independence and improved safety may be achieved more easily and time efficiently.
Garvey, E P; Hoekstra, W J; Schotzinger, R J; Sobel, J D; Lilly, E A; Fidel, P L
2015-09-01
Vulvovaginal candidiasis (VVC) and recurrent VVC (RVVC) remain major health problems for women. VT-1161, a novel fungal CYP51 inhibitor which has potent antifungal activity against fluconazole-sensitive Candida albicans, retained its in vitro potency (MIC50 of ≤0.015 and MIC90 of 0.12 μg/ml) against 10 clinical isolates from VVC or RVVC patients resistant to fluconazole (MIC50 of 8 and MIC90 of 64 μg/ml). VT-1161 pharmacokinetics in mice displayed a high volume of distribution (1.4 liters/kg), high oral absorption (73%), and a long half-life (>48 h) and showed rapid penetration into vaginal tissue. In a murine model of vaginal candidiasis using fluconazole-sensitive yeast, oral doses as low as 4 mg/kg VT-1161 significantly reduced the fungal burden 1 and 4 days posttreatment (P < 0.0001). Similar VT-1161 efficacy was measured when an isolate highly resistant to fluconazole (MIC of 64 μg/ml) but fully sensitive in vitro to VT-1161 was used. When an isolate partially sensitive to VT-1161 (MIC of 0.12 μg/ml) and moderately resistant to fluconazole (MIC of 8 μg/ml) was used, VT-1161 remained efficacious, whereas fluconazole was efficacious on day 1 but did not sustain efficacy 4 days posttreatment. Both agents were inactive in treating an infection with an isolate that demonstrated weaker potency (MICs of 2 and 64 μg/ml for VT-1161 and fluconazole, respectively). Finally, the plasma concentrations of free VT-1161 were predictive of efficacy when in excess of the in vitro MIC values. These data support the clinical development of VT-1161 as a potentially more efficacious treatment for VVC and RVVC. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
2014-01-01
Background: To aid decision making for pneumococcal conjugate vaccine (PCV) use in infant national immunization programs, we summarized the indirect effects of PCV on clinical outcomes among nontargeted age groups. Methods: We systematically reviewed the English literature on infant PCV dosing schedules published from 1994 to 2010 (with ad hoc addition of 2011 articles) for outcomes on children >5 years of age and adults including vaccine-type nasopharyngeal carriage (VT-NP), vaccine-type invasive pneumococcal disease (VT-IPD) and syndromic pneumonia. Results: Of 12,980 citations reviewed, we identified 21 VT-IPD, 6 VT-NP and 9 pneumonia studies. Of these 36, 21 (58%) included 3 primary doses plus PCV or pneumococcal polysaccharide vaccine (PPV23) booster schedule (3+1 or 3+PPV23), 5 (14%) 3+0, 9 (25%) 2+1 and 1 (3%) 2+0. Most (95%) were PCV7 studies. Among observational VT-IPD studies, all schedules (2+1, 3+0 and 3+1) demonstrated reductions in incidence among young adult groups. Among syndromic pneumonia observational studies (2+1, 3+0 and 3+1), only 3+1 schedules showed significant indirect impact. Of 2 VT-NP controlled trials (3+0 and 3+1) and 3 VT-NP observational studies (2+1, 3+1 and 3+PPV23), 3+1 and 3+PPV23 schedules showed significant indirect effect. The 1 study to directly compare between schedules was a VT-NP study (2+0 vs. 2+1), which found no indirect effect on older siblings and parents of vaccinated children with either schedule. Conclusions: Indirect benefit of a 3+1 infant PCV dosing schedule has been demonstrated for VT-IPD, VT-NP and syndromic pneumonia; 2+1 and 3+0 schedules have demonstrated indirect effect only for VT-IPD. The choice of optimal infant PCV schedule is limited by data paucity on indirect effects, especially a lack of head-to-head studies and studies of PCV10 and PCV13. PMID:24336058
Seita, Tetsurou; Kuribayashi, Takashi; Honjo, Toshio; Yamamoto, Shizuo
2013-04-01
The efficacy of bovine immune colostral (colostral) antibodies against verotoxin (VT) 2, flagellum and somatic cells of Escherichia coli (E. coli) O157:H7 in mice was determined. Three major immunoglobulin (Ig) classes were isolated from the colostral antibody against VT2 by affinity chromatography and were used for estimation. Mice inoculated with VT2 were administered each Ig class from the colostral antibody, colostral antibody (colostral whey containing antibody) or serum antibody against VT2 at 1 hour after VT2 inoculation. All control mice (20/20) died after administration of sterilized saline instead of the colostral antibody. The survival rate was 93.3% (14/15) after administration of S-IgA or IgM antibody, or colostral antibody. Survival rates for IgG antibody and serum antibody administration were 80% (12/15) and 60% (9/15), respectively. Serum concentrations of VT2, which was absorbed from the small intestine in mice after administration of VT2 and colostral antibody, were measured by fluorescence enzyme immunoassay (FEIA). Serum concentrations of VT2 after administration of colostral antibody were lower than those after administration of sterilized saline. Mice inoculated with VT2-producing E. coli 157:H7 were administered anti-flagellum or anti-somatic colostral antibodies. Survival rates for E. coli O157:H7-infected mice administered the anti-flagellum and anti-somatic colostral antibodies were 52.4% (11/21) and 22.2% (4/18), respectively. Furthermore, survival rates increased to 89.5% (17/19) with combined administration of anti-flagellum and anti-VT2 colostral antibodies. These results suggest that colostral antibodies against VT2, flagellum and somatic cells are effective against E. coli O157:H7 infection. Copyright © 2012. Published by Elsevier B.V.
Rhythms and outcomes of adult in-hospital cardiac arrest.
Meaney, Peter A; Nadkarni, Vinay M; Kern, Karl B; Indik, Julia H; Halperin, Henry R; Berg, Robert A
2010-01-01
To determine the relationship of electrocardiographic rhythm during cardiac arrest with survival outcomes. Prospective, observational study. Total of 411 hospitals in the National Registry of Cardiopulmonary Resuscitation. Total of 51,919 adult patients with pulseless cardiac arrests from April 1999 to July 2005. Registry data collected included first documented rhythm, patient demographics, pre-event data, event data, and survival and neurologic outcome data. Of 51,919 indexed cardiac arrests, first documented pulseless rhythm was ventricular tachycardia (VT) in 3810 (7%), ventricular fibrillation (VF) in 8718 (17%), pulseless electrical activity (PEA) in 19,262 (37%) and asystole 20,129 (39%). Subsequent VT/VF (that is, VT or VF occurring during resuscitation for PEA or asystole) occurred in 5154 (27%), with first documented rhythm of PEA and 4988 (25%) with asystole. Survival to hospital discharge rate was not different between those with first documented VF and VT (37% each, adjusted odds ratio [OR]) 1.08; 95% confidence interval [CI] 0.95-1.23). Survival to hospital discharge was slightly more likely after PEA than asystole (12% vs. 11%, adjusted OR 1.1; 95% CI 1.00-1.18), Survival to discharge was substantially more likely after first documented VT/VF than PEA/asystole (adjusted OR 1.68; 95% CI 1.55-1.82). Survival to discharge was also more likely after PEA/asystole without subsequent VT/VF compared with PEA/asystole with subsequent VT/VF (14% vs. 7% for PEA without vs. with subsequent VT/VF; 12% vs. 8% for asystole without vs. with subsequent VT/VF; adjusted OR 1.60; 95% CI, 1.44-1.80). Survival to hospital discharge was substantially more likely when the first documented rhythm was shockable rather than nonshockable, and slightly more likely after PEA than asystole. Survival to hospital discharge was less likely following PEA/asystole with subsequent VT/VF compared to PEA/asystole without subsequent VT/VF.
1981-01-01
HIGH DESELECT DON’T CARE +5 V IMPEDANCE IH DON ’T HtIGH PO1WEAR DOWN VI1 +5 CARE IMPEDENCE PULSED PR RXPAM V TO V +25 v DATA NPRGA IL VIH VIl t PRORAM...VERIFY V +25 V DATA OUT IL IL PRARAM INHtIBIT VIL +25 VIH HIGH IMPEDANCE *[HIRESlHOLD MEASUREMENT +25V VARY V DATA OUT OV TO VT IL DFPR0GROVA +25V...VIL.C’E - VIH ) ! [l VCC Active Power Supply Current 57 100 mA 2 (5T C VIL) VPP Current (VPP - 5 25V) 6 mA 2.3 Vi.l Output High Voltage 24 Volts IOH -400
Kosmidou, Ioanna; Embacher, Monica; McAndrew, Thomas; Dizon, José M; Mehran, Roxana; Ben-Yehuda, Ori; Mintz, Gary S; Stone, Gregg W
2017-11-15
The prevalence and impact of early ventricular arrhythmias (ventricular tachycardia [VT]/ventricular fibrillation [VF]) occurring before mechanical revascularization for acute ST segment elevation myocardial infarction (STEMI) treated with percutaneous coronary intervention are poorly understood. We sought to investigate the association between early VT/VF and long-term clinical outcomes using data from the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction trial. Among 3,602 patients with STEMI, 108 patients (3.0%) had early VT/VF. Baseline clinical characteristics were similar in patients with versus without early VT/VF. Patients with early VT/VF had shorter symptom-to-balloon times and lower left ventricular ejection fraction and underwent more frequent thrombectomy compared with patients without early VT/VF. Adjusted 3-year rates of all-cause death (15.7% vs 6.5%; adjusted hazard ratio 2.62, 95% confidence interval 1.48 to 4.61, p <0.001) and stent thrombosis (13.7% vs 5.7%; adjusted hazard ratio 2.74, 95% confidence interval 1.52 to 4.93, p <0.001) were significantly higher in patients with early VT/VF compared with patients without early VT/VF. In conclusion, in the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction trial, VT/VF occurring before coronary angiography and revascularization in patients with STEMI was strongly associated with increased 3-year rates of death and stent thrombosis. Further investigation into the mechanisms underlying the increased risk of early stent thrombosis in patients with early VT/VF is required. Copyright © 2017 Elsevier Inc. All rights reserved.
Roach, R E J; Lijfering, W M; Helmerhorst, F M; Cannegieter, S C; Rosendaal, F R; van Hylckama Vlieg, A
2013-01-01
Oral contraception (OC) and postmenopausal hormone therapy (HT) can be used to alleviate menopausal symptoms. However, the risk of venous thrombosis (VT) associated with OC use in women over 50 years old has never been assessed and the two preparations have not been directly compared. To determine and compare the risk of VT associated with OC and HT use. From a large case-control study, 2550 women aged over 50 years old, 1082 patients with a first VT and 1468 controls, were included. Odds ratios (ORs) and 95% confidence intervals for VT were calculated for OC-users (164 patients and 54 controls) and HT-users (88 patients and 102 controls) compared with non-hormone users (823 patients and 1304 controls). OC-users had a 6.3-fold (4.6-9.8) increased risk of VT. This ranged from 5.4 (3.3-8.9) for preparations containing levonorgestrel to 10.2 (4.8-21.7) for desogestrel. The VT-risk associated with oral HT use was 4.0 (1.8-8.2) for conjugated equine estrogen combined with medroxyprogesterone acetate and 3.9 (1.5-10.7) for micronized estradiol combined with norethisterone acetate. Non-oral HT did not increase the risk of VT: OR 1.1 (0.6-1.8). Relative risk estimates were further increased in hormone users with factor V Leiden, prothrombin G20210A or blood group non-O and hormone users with a family history of VT. In this study, non-oral HT seemed to be the safest hormonal preparation in women over 50 years old. OC use increased the VT risk the most, especially in women with inherited thrombophilia or a family history of VT. © 2012 International Society on Thrombosis and Haemostasis.
Boufouss, El Hafed; Francis, Laurent A; Kilchytska, Valeriya; Gérard, Pierre; Simon, Pascal; Flandre, Denis
2013-12-13
This paper presents an ultra-low power CMOS voltage reference circuit which is robust under biomedical extreme conditions, such as high temperature and high total ionized dose (TID) radiation. To achieve such performances, the voltage reference is designed in a suitable 130 nm Silicon-on-Insulator (SOI) industrial technology and is optimized to work in the subthreshold regime of the transistors. The design simulations have been performed over the temperature range of -40-200 °C and for different process corners. Robustness to radiation was simulated using custom model parameters including TID effects, such as mobilities and threshold voltages degradation. The proposed circuit has been tested up to high total radiation dose, i.e., 1 Mrad (Si) performed at three different temperatures (room temperature, 100 °C and 200 °C). The maximum drift of the reference voltage V(REF) depends on the considered temperature and on radiation dose; however, it remains lower than 10% of the mean value of 1.5 V. The typical power dissipation at 2.5 V supply voltage is about 20 μW at room temperature and only 75 μW at a high temperature of 200 °C. To understand the effects caused by the combination of high total ionizing dose and temperature on such voltage reference, the threshold voltages of the used SOI MOSFETs were extracted under different conditions. The evolution of V(REF) and power consumption with temperature and radiation dose can then be explained in terms of the different balance between fixed oxide charge and interface states build-up. The total occupied area including pad-ring is less than 0.09 mm2.
DNA Inversion on Conjugative Plasmid pVT745
Chen, Jinbiao; Leblanc, Donald J.; Galli, Dominique M.
2002-01-01
Plasmid pVT745 from Actinobacillus actinomycetemcomitans strain VT745 can be transferred to other A. actinomycetemcomitans strains at a frequency of 10−6. Screening of transconjugants revealed that the DNA of pDMG21A, a pVT745 derivative containing a kanamycin resistance gene, displayed a structural rearrangement after transfer. A 9-kb segment on the plasmid had switched orientation. The inversion was independent of RecA and required the activity of the pVT745-encoded site-specific recombinase. This recombinase, termed Inv, was highly homologous to invertases of the Din family. Two recombination sites of 22 bp, which are arranged in opposite orientation and which function as DNA crossover sequences, were identified on pVT745. One of the sites was located adjacent to the 5′ end of the invertase gene, inv. Inversion of the 9-kb segment on pVT745 derivatives has been observed in all A. actinomycetemcomitans strains tested except for the original host, VT745. This would suggest that a host factor that is either inactive or absent in VT745 is required for efficient recombination. Inactivation of the invertase in the donor strain resulted in a 1,000-fold increase in the number of transconjugants upon plasmid transfer. It is proposed that an activated invertase causes the immediate loss of the plasmid in most recipient cells after mating. No biological role has been associated with the invertase as of yet. PMID:12374826
Yang, Xiaolong; Yu, Zhijun; He, Yanjie; Xu, Xiaoli; Gao, Zhihua; Wang, Hui; Chen, Jie; Liu, Jingze
2015-03-01
Vitellin (Vt) was purified from eggs of parthenogenetic bush tick Haemaphysalis longicornis by gel filtration and ion exchange chromatography. Our results revealed that only one single Vt existed in parthenogenetic bush tick, and the purified Vt was proved to be a hemoglycolipoprotein consisting of nine polypeptides with molecular weights of 203, 147, 126, 82, 74, 70, 61, 47 and 31 kDa, respectively. Polyclonal antibody and monoclonal antibody against Vt were produced using the purified Vt. The change in vitellogenin (Vg) and Vt levels over time of the parthenogenetic H. longicornis was established, and the Vg content in haemolymph and Vt in ovary at different feeding or engorgement statuses was also determined using a double antibody sandwich enzyme-linked immunosorbent assay. The Vg level in haemolymph was distinctly increased on the day of engorgement (1.785 mg/mL) and continued to increase until 2nd day post-engorgement (5.611 mg/mL). There was a slight decrease in Vg level after 4 days of engorgement, and a second peak was observed on day 2 post-oviposition (10.774 mg/mL). Subsequently, Vg content continuously decreased and reached a low level on the 10th day post-oviposition. The Vt content in ovary continuously increased once the female reached its critical weight (0.024 mg per female), and reached the maximum level on day 2 post-oviposition (1.942 mg per female). Afterwards, Vt content rapidly decreased.
Occurrence of verotoxin-producing Escherichia coli in dairy heifers grazing an irrigated pasture.
Thran, B H; Hussein, H S; Hall, M R; Khaiboullina, S F
2001-02-28
Verotoxin-producing Escherichia coli (VTEC) produce one or two toxins known as VT1 and VT2. These toxins have been associated with several human illnesses. Dairy cattle harboring VTEC represent a potential health hazard because they enter the food chain as ground beef. The objective of this study was to assess the occurrence of VTEC in dairy heifers. A total of 91 fecal samples were rectally collected during four periods (spring, summer, fall, and winter of 1999) from 23 heifers. A random sample (n=530) of potential VTEC isolates were tested for verotoxicity and were screened by the polymerase chain reaction (PCR) for presence or absence of VT1 and/or VT2 genes. Thirteen isolates from two heifers (from the winter collection) were verotoxic and were confirmed as E. coli. VTEC were only detected during winter with an occurrence rate of 9.5%. Using PCR, five isolates had the VT1 gene while the remaining eight had the VT2 gene. The sequence and expression of VT1 and VT2 genes were confirmed. No E. coli O157:H7 was detected, but serotyping revealed that the five VT1-positive isolates were O26:NM (a non-motile strain of O26). The remaining eight isolates were untypeable. Identification of VTEC-positive cattle before slaughter is a critical step in any on-farm strategy to minimize the risk of beef contamination with such pathogens.
Genetics of Venous Thrombosis: Insights from a New Genome Wide Association Study
Germain, Marine; Saut, Noémie; Greliche, Nicolas; Dina, Christian; Lambert, Jean-Charles; Perret, Claire; Cohen, William; Oudot-Mellakh, Tiphaine; Antoni, Guillemette; Alessi, Marie-Christine; Zelenika, Diana; Cambien, François; Tiret, Laurence; Bertrand, Marion; Dupuy, Anne-Marie; Letenneur, Luc; Lathrop, Mark; Emmerich, Joseph; Amouyel, Philippe; Trégouët, David-Alexandre; Morange, Pierre-Emmanuel
2011-01-01
Background Venous Thrombosis (VT) is a common multifactorial disease associated with a major public health burden. Genetics factors are known to contribute to the susceptibility of the disease but how many genes are involved and their contribution to VT risk still remain obscure. We aimed to identify genetic variants associated with VT risk. Methodology/Principal Findings We conducted a genome-wide association study (GWAS) based on 551,141 SNPs genotyped in 1,542 cases and 1,110 controls. Twelve SNPs reached the genome-wide significance level of 2.0×10−8 and encompassed four known VT-associated loci, ABO, F5, F11 and FGG. By means of haplotype analyses, we also provided novel arguments in favor of a role of HIVEP1, PROCR and STAB2, three loci recently hypothesized to participate in the susceptibility to VT. However, no novel VT-associated loci came out of our GWAS. Using a recently proposed statistical methodology, we also showed that common variants could explain about 35% of the genetic variance underlying VT susceptibility among which 3% could be attributable to the main identified VT loci. This analysis additionally suggested that the common variants left to be identified are not uniformly distributed across the genome and that chromosome 20, itself, could contribute to ∼7% of the total genetic variance. Conclusions/Significance This study might also provide a valuable source of information to expand our understanding of biological mechanisms regulating quantitative biomarkers for VT. PMID:21980494
Effect of Wheelchair Frame Material on Users' Mechanical Work and Transmitted Vibration
Aissaoui, Rachid
2014-01-01
Wheelchair propulsion exposes the user to a high risk of shoulder injury and to whole-body vibration that exceeds recommendations of ISO 2631-1:1997. Reducing the mechanical work required to travel a given distance (WN-WPM, weight-normalized work-per-meter) can help reduce the risk of shoulder injury, while reducing the vibration transmissibility (VT) of the wheelchair frame can reduce whole-body vibration. New materials such as titanium and carbon are used in today's wheelchairs and are advertised to improve both parameters, but current knowledge on this matter is limited. In this study, WN-WPM and VT were measured simultaneously and compared between six folding wheelchairs (1 titanium, 1 carbon, and 4 aluminium). Ten able-bodied users propelled the six wheelchairs on three ground surfaces. Although no significant difference of WN-WPM was found between wheelchairs (P < 0.1), significant differences of VT were found (P < 0.05). The carbon wheelchair had the lowest VT. Contrarily to current belief, the titanium wheelchair VT was similar to aluminium wheelchairs. A negative correlation between VT and WN-WPM was found, which means that reducing VT may be at the expense of increasing WN-WPM. Based on our results, use of carbon in wheelchair construction seems promising to reduce VT without increasing WN-WPM. PMID:25276802
Tsai, Ching-Fent; Wang, Kun-Teng; Chen, Lih-Geeng; Lee, Chia-Jung; Tseng, Sung-Hui
2014-01-01
Abstract Vitis thunbergii Sieb. et Zucc. var. taiwaniana Lu (VT) is an indigenous plant in Taiwan that is traditionally used for promoting joint health. In this study, we used in vitro primary human chondrocytes (PHCs) and two in vivo animal models to evaluate the anti-inflammatory effects of VT on arthritis. Results showed that the water extract of the stems and roots from VT (VT-SR) was rich in flavones and phenols with 1.1 mg/g of resveratrol, 6.7 mg/g of hopeaphenol, and 5.1 mg/g of (+)-ɛ-viniferin. VT-SR significantly scavenged DPPH radicals and inhibited prostaglandin E2 (PGE2) production in lipopolysaccharide (LPS)-induced PHCs without exhibiting significant cytotoxicity. In in vivo models, the VT-SR (500 mg/kg) significantly decreased serum PGE2 and knee 2-18F-fluoro-2-deoxy-D-glucose (18F-FDG) levels in LPS-induced acute inflammatory arthritis in rabbits. In addition, dietary supplementation with VT-SR for 28 days significantly alleviated type II collagenase-induced rat osteoarthritis with improvements in weight bearing and range of motion tests. In conclusion, our results suggest that the VT-SR is a good candidate for developing dietary supplements to prevent joint deterioration and inhibit inflammation. PMID:24720858
Lassnig, R.; Striedinger, B.; Hollerer, M.; Fian, A.; Stadlober, B.; Winkler, A.
2015-01-01
The fabrication of organic thin film transistors with highly reproducible characteristics presents a very challenging task. We have prepared and analyzed model pentacene thin film transistors under ultra-high vacuum conditions, employing surface analytical tools and methods. Intentionally contaminating the gold contacts and SiO2 channel area with carbon through repeated adsorption, dissociation, and desorption of pentacene proved to be very advantageous in the creation of devices with stable and reproducible parameters. We mainly focused on the device properties, such as mobility and threshold voltage, as a function of film morphology and preparation temperature. At 300 K, pentacene displays Stranski-Krastanov growth, whereas at 200 K fine-grained, layer-like film growth takes place, which predominantly influences the threshold voltage. Temperature dependent mobility measurements demonstrate good agreement with the established multiple trapping and release model, which in turn indicates a predominant concentration of shallow traps in the crystal grains and at the oxide-semiconductor interface. Mobility and threshold voltage measurements as a function of coverage reveal that up to four full monolayers contribute to the overall charge transport. A significant influence on the effective mobility also stems from the access resistance at the gold contact-semiconductor interface, which is again strongly influenced by the temperature dependent, characteristic film growth mode. PMID:25814770
NASA Astrophysics Data System (ADS)
Lassnig, R.; Striedinger, B.; Hollerer, M.; Fian, A.; Stadlober, B.; Winkler, A.
2014-09-01
The fabrication of organic thin film transistors with highly reproducible characteristics presents a very challenging task. We have prepared and analyzed model pentacene thin film transistors under ultra-high vacuum conditions, employing surface analytical tools and methods. Intentionally contaminating the gold contacts and SiO2 channel area with carbon through repeated adsorption, dissociation, and desorption of pentacene proved to be very advantageous in the creation of devices with stable and reproducible parameters. We mainly focused on the device properties, such as mobility and threshold voltage, as a function of film morphology and preparation temperature. At 300 K, pentacene displays Stranski-Krastanov growth, whereas at 200 K fine-grained, layer-like film growth takes place, which predominantly influences the threshold voltage. Temperature dependent mobility measurements demonstrate good agreement with the established multiple trapping and release model, which in turn indicates a predominant concentration of shallow traps in the crystal grains and at the oxide-semiconductor interface. Mobility and threshold voltage measurements as a function of coverage reveal that up to four full monolayers contribute to the overall charge transport. A significant influence on the effective mobility also stems from the access resistance at the gold contact-semiconductor interface, which is again strongly influenced by the temperature dependent, characteristic film growth mode.
The endophyte Verticillium Vt305 protects cauliflower against Verticillium wilt.
Tyvaert, L; França, S C; Debode, J; Höfte, M
2014-06-01
To investigate the interaction between cauliflower and the isolate VerticilliumVt305, obtained from a field suppressive to Verticillium wilt of cauliflower, and to evaluate the ability of VerticilliumVt305 to control Verticillium wilt of cauliflower caused by V. longisporum. Single and combined inoculations of VerticilliumVt305 and V. longisporum were performed on cauliflower seedlings. Symptom development was evaluated, and fungal colonization was measured in the roots, hypocotyl and stem with real-time PCR. No symptoms were observed after single inoculation of VerticilliumVt305, although it colonized the plant tissues. Pre-inoculation of VerticilliumVt305 reduced symptom development and colonization of plant tissues by V. longisporum. VerticilliumVt305 is an endophyte on cauliflower plants and showed effective biological control of V. longisporum in controlled conditions. This work can contribute to the development of a sustainable control measure of V. longisporum in Brassicaceae hosts, which is currently not available. Additionally, this study provides evidence for the different roles of Verticillium species present in the agro-ecosystem. © 2014 The Society for Applied Microbiology.
Ning, Xiaohui; Ye, Xuerui; Si, Yanhua; Yang, Zihe; Zhao, Yunzi; Sun, Qi; Chen, Ruohan; Tang, Min; Chen, Keping; Zhang, Xiaoli; Zhang, Shu
2018-03-21
We investigated the prevalence of ventricular tachycardia/ventricular fibrillation (VT/VF) in Post-infarction left ventricular aneurysm (PI-LVA) patients and analyze clinical outcomes in patients presenting with VT/VF. 575 PI-LVA patients were enrolled and investigated by logistic regression analysis. Patients with VT/VF were followed up, the composite primary endpoint was cardiac death and appropriate ICD/external shocks. The incidence of sustained VT/VF was 11%. Logistical regression analysis showed male gender, enlarged LV end diastolic diameter (LVEDD) and higher NYHA class were correlated with VT/VF development. During follow up of 46 ± 15 months, 19 out of 62(31%) patients reached study end point. Multivariate Cox regression analysis revealed that enlarged LVEDD and moderate/severe mitral regurgitation (MR) were independently predictive of clinical outcome. Male gender, enlarged LVEDD and higher NYHA class associated with risk of sustained VT/VF in PI-LVA patients. Among VT/VF positive patients, enlarged LVEDD and moderate/severe MR independently predicted poor clinical prognosis. Copyright © 2018. Published by Elsevier Inc.
Advanced Initiation Systems Manufacturing Level 2 Milestone Completion Summary
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chow, R; Schmidt, M
2009-10-01
Milestone Description - Advanced Initiation Systems Detonator Design and Prototype. Milestone Grading Criteria - Design new generation chip slapper detonator and manufacture a prototype using advanced manufacturing processes, such as all-dry chip metallization and solvent-less flyer coatings. The advanced processes have been developed for manufacturing detonators with high material compatibility and reliability to support future LEPs, e.g. the B61, and new weapons systems. Perform velocimetry measurements to determine slapper velocity as a function of flight distance. A prototype detonator assembly and stripline was designed for low-energy chip slappers. Pictures of the prototype detonator and stripline are shown. All-dry manufacturing processesmore » were used to address compatibility issues. KCP metallized the chips in a physical vapor deposition system through precision-aligned shadow masks. LLNL deposited a solvent-less polyimide flyer with a processes called SLIP, which stands for solvent-less vapor deposition followed by in-situ polymerization. LANL manufactured the high-surface-area (HSA) high explosive (HE) pellets. Test fires of two chip slapper designs, radius and bowtie, were performed at LLNL in the High Explosives Application Facility (HEAF). Test fires with HE were conducted to establish the threshold firing voltages. pictures of the chip slappers before and after test fires are shown. Velocimetry tests were then performed to obtain slapper velocities at or above the threshold firing voltages. Figure 5 shows the slapper velocity as a function of distance and time at the threshold voltage, for both radius and bowtie bridge designs. Both designs were successful at initiating the HE at low energy levels. Summary of Accomplishments are: (1) All-dry process for chip manufacture developed; (2) Solventless process for slapper materials developed; (3) High-surface area explosive pellets developed; (4) High performance chip slappers developed; (5) Low-energy chip slapper detonator designs; and (6) Low-voltage threshold chip slapper detonator demonstrated.« less
Yaksh, Ameeta; Kik, Charles; Knops, Paul; Zwiers, Korinne; van Ettinger, Maarten J B; Manintveld, Olivier C; de Wijs, Marcel C J; van der Kemp, Peter; Bogers, Ad J J C; de Groot, Natasja M S
2016-07-08
Early postoperative ventricular tachyarrhythmia (PoVT) after left ventricular assist device (LVAD) implantation are common and associated with higher mortality-rates. At present, there is no data on initiation of these PoVT and the role of alterations in cardiac hemodynamics. A LVAD was implanted in a patient with end-stage heart failure due to a ischemic cardiomyopathy. Alterations in cardiac rhythm and hemodynamics preceding PoVT-episodes during the first five postoperative days were examined by using continuous recordings of cardiac rhythm and various hemodynamic parameters. All PoVT (N=120) were monomorphic, most often preceded by short-long-short-sequences or regular SR and initiated by ventricular runs. Prior to PoVT, mean arterial pressure decreased; heart rate and ST-segments deviations increased. PoVT are caused by different underlying electrophysiological mechanisms. Yet, they are all monomorphic and preceded by hemodynamic deterioration due to myocardial ischemia.
George, W D; Godfrey, R W; Ketring, R C; Vinson, M C; Willard, S T
2014-11-01
Digital infrared thermal imaging (DITI) using a thermal camera has potential to be a useful tool for the production animal industry. Thermography has been used in both humans and a wide range of animal species to measure body temperature as a method to detect injury or inflammation. The objective of these experiments was to compare the temperature of the eye (EYE) or muzzle (MUZ) measured using DITI to vaginal (VT) and rectal temperature (RT) as measures of core body temperature in hair sheep and beef cattle. In Exp.1 EYE, VT and RT were measured in lactating, multiparous hair sheep ewes (St. Croix White, n = 10, and Dorper × St. Croix White, n = 10) in a non-febrile state 5 times over a 48-h period. Data loggers were used to measure VT and a digital veterinary thermometer was used to measure RT. There was a high correlation (P < 0.001) between VT and RT (r = 0.95), EYE and RT (r = 0.76) and EYE and VT (r = 0.77). In Exp. 2 EYE, MUZ, VT and RT were measured in multiparous, lactating ewes (St. Croix White, n = 2, and Barbados Blackbelly, n = 12) at -12, -1, 0, 1, 2, 3, 4, 6, 12, 24, 36, and 48 h after being administered lipopolysaccharide (LPS; n = 7; 0.2 µg/kg BW, i.v.) or saline (n = 7; 0.5 mL, i.v.). Data loggers were used to measure VT and a digital veterinary thermometer was used to measure RT. When data were combined across treatments (LPS and saline) there was a high correlation (P < 0.001) between VT and RT (r = 0.96), EYE and RT (r = 0.82), MUZ and RT (r = 0.72), and EYE and VT (r = 0.93). In Exp. 3 EYE, MUZ, VT and RT were measured in multiparous, non-lactating, pregnant Senepol cattle (n = 44) between 0900 and 1200 h on a single day. A digital veterinary thermometer was used to measure both VT and RT. There was a high correlation (P < 0.001) between VT and RT (r = 0.78), a moderate correlation (P < 0.001) between VT and EYE (r = 0.52), RT and EYE (r = 0.58) and EYE and MUZ (r = 0.48). There was no correlation (P > 0.10) between RT or VT and MUZ. The findings of these three studies indicate that temperature of the eye, measured using DITI, can be used as an indicator of core body temperature in hair sheep and beef cattle as an alternative to using vaginal or rectal temperature.
Tunnel magnetoresistance for coherent spin-flip processes on an interacting quantum dot.
Rudziński, W
2009-01-28
Spin-polarized electronic tunneling through a quantum dot coupled to ferromagnetic electrodes is investigated within a nonequilibrium Green function approach. An interplay between coherent intradot spin-flip transitions, tunneling processes and Coulomb correlations on the dot is studied for current-voltage characteristics of the tunneling junction in parallel and antiparallel magnetic configurations of the leads. It is found that due to the spin-flip processes electric current in the antiparallel configuration tends to the current characteristics in the parallel configuration, thus giving rise to suppression of the tunnel magnetoresistance (TMR) between the threshold bias voltages at which the dot energy level becomes active in tunneling. Also, the effect of a negative differential conductance in symmetrical junctions, splitting of the conductance peaks, significant modulation of TMR peaks around the threshold bias voltages as well as suppression of the diode-like behavior in asymmetrical junctions is discussed in the context of coherent intradot spin-flip transitions. It is also shown that TMR may be inverted at selected gate voltages, which qualitatively reproduces the TMR behavior predicted recently for temperatures in the Kondo regime, and observed experimentally beyond the Kondo regime for a semiconductor InAs quantum dot coupled to nickel electrodes.
An “ohmic-first” self-terminating gate-recess technique for normally-off Al2O3/GaN MOSFET
NASA Astrophysics Data System (ADS)
Wang, Hongyue; Wang, Jinyan; Li, Mengjun; He, Yandong; Wang, Maojun; Yu, Min; Wu, Wengang; Zhou, Yang; Dai, Gang
2018-04-01
In this article, an ohmic-first AlGaN/GaN self-terminating gate-recess etching technique was demonstrated where ohmic contact formation is ahead of gate-recess-etching/gate-dielectric-deposition (GRE/GDD) process. The ohmic contact exhibits few degradations after the self-terminating gate-recess process. Besides, when comparing with that using the conventional fabrication process, the fabricated device using the ohmic-first fabrication process shows a better gate dielectric quality in terms of more than 3 orders lower forward gate leakage current, more than twice higher reverse breakdown voltage as well as better stability. Based on this proposed technique, the normally-off Al2O3/GaN MOSFET exhibits a threshold voltage (V th) of ˜1.8 V, a maximum drain current of ˜328 mA/mm, a forward gate leakage current of ˜10-6 A/mm and an off-state breakdown voltage of 218 V at room temperature. Meanwhile, high temperature characteristics of the device was also evaluated and small variations (˜7.6%) of the threshold voltage was confirmed up to 300 °C.
NASA Astrophysics Data System (ADS)
Khadem Hosseini, Vahideh; Ahmadi, Mohammad Taghi; Ismail, Razali
2018-05-01
The single electron transistor (SET) as a fast electronic device is a candidate for future nanoscale circuits because of its low energy consumption, small size and simplified circuit. It consists of source and drain electrodes with a quantum dot (QD) located between them. Moreover, it operates based on the Coulomb blockade (CB) effect. It occurs when the charging energy is greater than the thermal energy. Consequently, this condition limits SET operation at cryogenic temperatures. Hence, using QD arrays can overcome this temperature limitation in SET which can therefore work at room temperature but QD arrays increase the threshold voltage with is an undesirable effect. In this research, fullerene as a zero-dimensional material with unique properties such as quantum capacitance and high critical temperature has been selected for the material of the QDs. Moreover, the current of a fullerene QD array SET has been modeled and its threshold voltage is also compared with a silicon QD array SET. The results show that the threshold voltage of fullerene SET is lower than the silicon one. Furthermore, the comparison study shows that homogeneous linear QD arrays have a lower CB range and better operation than a ring QD array SET. Moreover, the effect of the number of QDs in a QD array SET is investigated. The result confirms that the number of QDs can directly affect the CB range. Moreover, the desired current can be achieved by controlling the applied gate voltage and island diameters in a QD array SET.
Keum, Dongil; Kim, Dong-Il; Suh, Byung-Chang
2016-01-01
Voltage-sensing phosphatases (VSPs) are homologs of phosphatase and tensin homolog (PTEN), a phosphatidylinositol 3,4-bisphosphate [PI(3,4)P2] and phosphatidylinositol 3,4,5-trisphosphate [PI(3,4,5)P3] 3-phosphatase. However, VSPs have a wider range of substrates, cleaving 3-phosphate from PI(3,4)P2 and probably PI(3,4,5)P3 as well as 5-phosphate from phosphatidylinositol 4,5-bisphosphate [PI(4,5)P2] and PI(3,4,5)P3 in response to membrane depolarization. Recent proposals say these reactions have differing voltage dependence. Using Förster resonance energy transfer probes specific for different PIs in living cells with zebrafish VSP, we quantitate both voltage-dependent 5- and 3-phosphatase subreactions against endogenous substrates. These activities become apparent with different voltage thresholds, voltage sensitivities, and catalytic rates. As an analytical tool, we refine a kinetic model that includes the endogenous pools of phosphoinositides, endogenous phosphatase and kinase reactions connecting them, and four exogenous voltage-dependent 5- and 3-phosphatase subreactions of VSP. We show that apparent voltage threshold differences for seeing effects of the 5- and 3-phosphatase activities in cells are not due to different intrinsic voltage dependence of these reactions. Rather, the reactions have a common voltage dependence, and apparent differences arise only because each VSP subreaction has a different absolute catalytic rate that begins to surpass the respective endogenous enzyme activities at different voltages. For zebrafish VSP, our modeling revealed that 3-phosphatase activity against PI(3,4,5)P3 is 55-fold slower than 5-phosphatase activity against PI(4,5)P2; thus, PI(4,5)P2 generated more slowly from dephosphorylating PI(3,4,5)P3 might never accumulate. When 5-phosphatase activity was counteracted by coexpression of a phosphatidylinositol 4-phosphate 5-kinase, there was accumulation of PI(4,5)P2 in parallel to PI(3,4,5)P3 dephosphorylation, emphasizing that VSPs can cleave the 3-phosphate of PI(3,4,5)P3. PMID:27222577
Influence of the magnetic field profile on ITER conductor testing
NASA Astrophysics Data System (ADS)
Nijhuis, A.; Ilyin, Y.; ten Kate, H. H. J.
2006-08-01
We performed simulations with the numerical CUDI-CICC code on a typical short ITER (International Thermonuclear Experimental Reactor) conductor test sample of dual leg configuration, as usually tested in the SULTAN test facility, and made a comparison with the new EFDA-Dipole test facility offering a larger applied DC field region. The new EFDA-Dipole test facility, designed for short sample testing of conductors for ITER, has a homogeneous high field region of 1.2 m, while in the SULTAN facility this region is three times shorter. The inevitable non-uniformity of the current distribution in the cable, introduced by the joints at both ends, has a degrading effect on voltage-current (VI) and voltage-temperature (VT) characteristics, particularly for these short samples. This can easily result in an underestimation or overestimation of the actual conductor performance. A longer applied DC high field region along a conductor suppresses the current non-uniformity by increasing the overall longitudinal cable electric field when reaching the current sharing mode. The numerical interpretation study presented here gives a quantitative analysis for a relevant practical case of a test of a short sample poloidal field coil insert (PFCI) conductor in SULTAN. The simulation includes the results of current distribution analysis from self-field measurements with Hall sensor arrays, current sharing measurements and inter-petal resistance measurements. The outcome of the simulations confirms that the current uniformity improves with a longer high field region but the 'measured' VI transition is barely affected, though the local peak voltages become somewhat suppressed. It appears that the location of the high field region and voltage taps has practically no influence on the VI curve as long as the transverse voltage components are adequately cancelled. In particular, for a thin conduit wall, the voltage taps should be connected to the conduit in the form of an (open) azimuthally soldered wire, averaging the transverse conduit surface potentials initiated in the joints.
NASA Astrophysics Data System (ADS)
Lin, Hui; Kong, Xiao; Li, Yiran; Kuang, Peng; Tao, Silu
2018-03-01
In this article, we have investigated the effect of nanocomposite gate dielectric layer built by alumina (Al2O3) and poly(4-vinyphenol) (PVP) with solution method which could enhance the dielectric capability and decrease the surface polarity. Then, we used modify layer to optimize the surface morphology of dielectric layer to further improve the insulation capability, and finally we fabricated the high-performance and low-voltage organic thin-film transistors by using this nanocomposite dielectric layer. The result shows that the devices with Al2O3:10%PVP dielectric layer with a modified layer exhibited a mobility of 0.49 cm2/Vs, I on/Ioff ratio of 7.8 × 104, threshold voltage of - 1.2 V, sub-threshold swing of 0.3 V/dec, and operating voltage as low as - 4 V. The improvement of devices performance was owing to the good insulation capability, appropriate capacitance of dielectric layer, and preferable interface contact, smaller crystalline size of active layer.
Physical implication of transition voltage in organic nano-floating-gate nonvolatile memories
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Shun; Gao, Xu, E-mail: wangsd@suda.edu.cn, E-mail: gaoxu@suda.edu.cn; Zhong, Ya-Nan
High-performance pentacene-based organic field-effect transistor nonvolatile memories, using polystyrene as a tunneling dielectric and Au nanoparticles as a nano-floating-gate, show parallelogram-like transfer characteristics with a featured transition point. The transition voltage at the transition point corresponds to a threshold electric field in the tunneling dielectric, over which stored electrons in the nano-floating-gate will start to leak out. The transition voltage can be modulated depending on the bias configuration and device structure. For p-type active layers, optimized transition voltage should be on the negative side of but close to the reading voltage, which can simultaneously achieve a high ON/OFF ratio andmore » good memory retention.« less
The role of pore fluids on deforming volcanic rocks: an experimental study
NASA Astrophysics Data System (ADS)
Fazio, Marco; Benson, Philip; Vinciguerra, Sergio; Meredith, Philip
2015-04-01
Pore fluids play an important role on the process of the deformation of rocks. Not only it affects the mechanical properties and the elastic velocities of the material, but it is also responsible in the generation of a whole kind of seismicity, characterized by lower frequency and longer tail (i.e. Long Period, LP, and Hybrid events) than the Volcano-Tectonic (VT) signals, generated by simple shear. While great progress has been made in understanding VT events, LPs, Hybrid signals and the transition between these types of activity are not fully understood yet. This study, aiming in particular on the transition between VT and Hybrid events, shows the results of triaxial experiments on a volcanic rock, run both in dry and wet conditions, to better understand the role of the pore fluids on the final stage of the deformation tests, when the sample is approaching failure. This is achieved through a servo-controlled triaxial testing machine and a state-of the-art acoustic emissions (AEs) kit, composed by an array of 12 piezoelectric sensors surrounding the sample and by both a "triggered" unit, where the events are recorded only if a certain threshold is reached, and a "continuous" unit, where the data is recorded from the beginning to the end of the acquisition, fundamental when the AEs grow exponentially and the triggered unit cannot store at the same rate. The use of sensors of different dominant frequency allows us to better investigate the events occurring as the sample is approaching failure. In both conditions we observe a decrease of the dominant frequency of the seismic activity, due to two different processes: in dry conditions the coalescence of fractures, eventually leading to the major shear zone, creates relatively low-frequency VT events; the same occurs in wet conditions, but the movement of fluids, eased by the merging of the cracks, generates hybrid events. These two type of seismicity are then distinguished in terms of their source mechanism components, where the low-frequency VTs are characterized by a higher DC component, while hybrid events show a greater CLVD one. These results may have a great impacts in the failure forecasting models, not only in volcanic settings, but wherever the pore fluids play an important role on the stability of the rock mass.
Volume Transmission in Central Dopamine and Noradrenaline Neurons and Its Astroglial Targets.
Fuxe, Kjell; Agnati, Luigi F; Marcoli, Manuela; Borroto-Escuela, Dasiel O
2015-12-01
Already in the 1960s the architecture and pharmacology of the brainstem dopamine (DA) and noradrenaline (NA) neurons with formation of vast numbers of DA and NA terminal plexa of the central nervous system (CNS) indicated that they may not only communicate via synaptic transmission. In the 1980s the theory of volume transmission (VT) was introduced as a major communication together with synaptic transmission in the CNS. VT is an extracellular and cerebrospinal fluid transmission of chemical signals like transmitters, modulators etc. moving along energy gradients making diffusion and flow of VT signals possible. VT interacts with synaptic transmission mainly through direct receptor-receptor interactions in synaptic and extrasynaptic heteroreceptor complexes and their signaling cascades. The DA and NA neurons are specialized for extrasynaptic VT at the soma-dendrtitic and terminal level. The catecholamines released target multiple DA and adrenergic subtypes on nerve cells, astroglia and microglia which are the major cell components of the trophic units building up the neural-glial networks of the CNS. DA and NA VT can modulate not only the strength of synaptic transmission but also the VT signaling of the astroglia and microglia of high relevance for neuron-glia interactions. The catecholamine VT targeting astroglia can modulate the fundamental functions of astroglia observed in neuroenergetics, in the Glymphatic system, in the central renin-angiotensin system and in the production of long-distance calcium waves. Also the astrocytic and microglial DA and adrenergic receptor subtypes mediating DA and NA VT can be significant drug targets in neurological and psychiatric disease.
Virtual cathode emission of an annular cold cathode
NASA Astrophysics Data System (ADS)
Park, S.-d.; Kim, J.-h.; Han, J.; Yoon, M.; Park, S. Y.; Choi, D. W.; Shin, J. W.; So, J. H.
2009-11-01
Recent measurement of voltage V and current I of the electron gun of a relativistic klystron amplifier revealed that the resulting current-voltage relationship appeared to differ from the usual Child-Langmuir law (I∝V3/2) especially during the initial period of voltage increase. This paper attempts to explain this deviation by examining the emission mechanism using particle-in-cell simulation. The emission area in the cathode increased stepwise as the applied voltage increased and within each step the current and voltage followed the Child-Langmuir law. The electron emission began when the voltage reached a threshold, and the perveance increased with the emission area. Furthermore, an apparent virtual cathode was formed which was larger than the cathode tip. This occurs because, above a certain voltage, the emission from the edge and the side of the cathode surface dominates the emission from the front-end surface.
Spike-Threshold Adaptation Predicted by Membrane Potential Dynamics In Vivo
Fontaine, Bertrand; Peña, José Luis; Brette, Romain
2014-01-01
Neurons encode information in sequences of spikes, which are triggered when their membrane potential crosses a threshold. In vivo, the spiking threshold displays large variability suggesting that threshold dynamics have a profound influence on how the combined input of a neuron is encoded in the spiking. Threshold variability could be explained by adaptation to the membrane potential. However, it could also be the case that most threshold variability reflects noise and processes other than threshold adaptation. Here, we investigated threshold variation in auditory neurons responses recorded in vivo in barn owls. We found that spike threshold is quantitatively predicted by a model in which the threshold adapts, tracking the membrane potential at a short timescale. As a result, in these neurons, slow voltage fluctuations do not contribute to spiking because they are filtered by threshold adaptation. More importantly, these neurons can only respond to input spikes arriving together on a millisecond timescale. These results demonstrate that fast adaptation to the membrane potential captures spike threshold variability in vivo. PMID:24722397
Pharmacological Tie2 activation in kidney transplantation.
Thamm, Kristina; Njau, Florence; Van Slyke, Paul; Dumont, Daniel J; Park, Joon-Keun; Haller, Hermann; David, Sascha
2016-09-24
To investigate the therapeutic potential of vasculotide (VT) - a Tie2 activating therapeutic - in kidney transplantation. We performed a murine MHC-mismatched renal transplant model (C57Bl/6 male into Balb/c female) with 60 min cold and 30 min warm ischemia time. 500 ng VT was administered i.p. to donor mice 1 h before organ removal. In addition, recipients received 500 ng VT i.p. directly and 3 d after surgery. Survival was monitored and remaining animals were sacrificed 28 d after transplantation. In this model, we analyzed: (1) organ function; (2) Kaplan-Meier survival; (3) organ damage (periodic acid Schiff staining) via semi-quantitative scoring [0-4 (0 = no injury/inflammation to 4 = very severe injury/inflammation)]; (4) expression of renal endothelial adhesion molecules (ICAM-1) via immunofluorescence (IF) staining, immunoblotting and qPCR; (5) infiltration of inflammatory cells (IF Gr-1, F4/80); and (6) fibrosis via staining of α-smooth muscle actin (αSMA), Sirius red staining and immunoblotting of SMAD3 activation. Exogenous activation of Tie2 with VT resulted in diminished expression of peritubular and glomerular endothelial adhesion molecules. Consequently, infiltration of inflammatory cells (analyzed as ICAM-1, Gr-1 and F4/80 positive cells) was reduced in VT-treated mice compared to controls. Additionally, VT was protective against fibrogenesis after kidney transplantation. Trends towards lower serum creatinine (vehicle: 142 ± 17 μmol/L vs VT: 94 ± 23 μmol/L), urea (vehicle: 76 ± 5 mmol/L vs VT: 60 ± 8 mmol/L) and lactate dehydrogenase (vehicle: 1288 ± 383 iU vs VT: 870 ± 275 iU) were observed on day 6 after transplantation. Kaplan-Meier survival analysis showed improved survival rates in the VT-treated mice that did not reach statistical significance (27% vs 54%, P = 0.24, n = 11 per group). Exogenous activation of Tie2 via VT might reduce infiltration of inflammatory cells into renal tissue thereby protecting the transplant from early graft dysfunction potentially affecting long-term function. Protection of the endothelial microvasculature via the Tie2 axis in the early transplant setting might hold promise as a therapeutic target.
AC electrified jets in a flow-focusing device: Jet length scaling
García-Sánchez, Pablo; Alzaga-Gimeno, Javier; Baret, Jean-Christophe
2016-01-01
We use a microfluidic flow-focusing device with integrated electrodes for controlling the production of water-in-oil drops. In a previous work, we reported that very long jets can be formed upon application of AC fields. We now study in detail the appearance of the long jets as a function of the electrical parameters, i.e., water conductivity, signal frequency, and voltage amplitude. For intermediate frequencies, we find a threshold voltage above which the jet length rapidly increases. Interestingly, this abrupt transition vanishes for high frequencies of the signal and the jet length grows smoothly with voltage. For frequencies below a threshold value, we previously reported a transition from a well-behaved uniform jet to highly unstable liquid structures in which axisymmetry is lost rather abruptly. These liquid filaments eventually break into droplets of different sizes. In this work, we characterize this transition with a diagram as a function of voltage and liquid conductivity. The electrical response of the long jets was studied via a distributed element circuit model. The model allows us to estimate the electric potential at the tip of the jet revealing that, for any combination of the electrical parameters, the breakup of the jet occurs at a critical value of this potential. We show that this voltage is around 550 V for our device geometry and choice of flow rates. PMID:27375826
AC electrified jets in a flow-focusing device: Jet length scaling.
Castro-Hernández, Elena; García-Sánchez, Pablo; Alzaga-Gimeno, Javier; Tan, Say Hwa; Baret, Jean-Christophe; Ramos, Antonio
2016-07-01
We use a microfluidic flow-focusing device with integrated electrodes for controlling the production of water-in-oil drops. In a previous work, we reported that very long jets can be formed upon application of AC fields. We now study in detail the appearance of the long jets as a function of the electrical parameters, i.e., water conductivity, signal frequency, and voltage amplitude. For intermediate frequencies, we find a threshold voltage above which the jet length rapidly increases. Interestingly, this abrupt transition vanishes for high frequencies of the signal and the jet length grows smoothly with voltage. For frequencies below a threshold value, we previously reported a transition from a well-behaved uniform jet to highly unstable liquid structures in which axisymmetry is lost rather abruptly. These liquid filaments eventually break into droplets of different sizes. In this work, we characterize this transition with a diagram as a function of voltage and liquid conductivity. The electrical response of the long jets was studied via a distributed element circuit model. The model allows us to estimate the electric potential at the tip of the jet revealing that, for any combination of the electrical parameters, the breakup of the jet occurs at a critical value of this potential. We show that this voltage is around 550 V for our device geometry and choice of flow rates.
Results of the 2015 testbeam of a 180 nm AMS High-Voltage CMOS sensor prototype
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benoit, M.; de Mendizabal, J. Bilbao; Casse, G.
We investigated the active pixel sensors based on the High-Voltage CMOS technology as a viable option for the future pixel tracker of the ATLAS experiment at the High-Luminosity LHC. Our paper reports on the testbeam measurements performed at the H8 beamline of the CERN Super Proton Synchrotron on a High-Voltage CMOS sensor prototype produced in 180 nm AMS technology. These results in terms of tracking efficiency and timing performance, for different threshold and bias conditions, are shown.
Results of the 2015 testbeam of a 180 nm AMS High-Voltage CMOS sensor prototype
Benoit, M.; de Mendizabal, J. Bilbao; Casse, G.; ...
2016-07-21
We investigated the active pixel sensors based on the High-Voltage CMOS technology as a viable option for the future pixel tracker of the ATLAS experiment at the High-Luminosity LHC. Our paper reports on the testbeam measurements performed at the H8 beamline of the CERN Super Proton Synchrotron on a High-Voltage CMOS sensor prototype produced in 180 nm AMS technology. These results in terms of tracking efficiency and timing performance, for different threshold and bias conditions, are shown.
New design of a passive type RADFET reader for enhanced sensitivity
NASA Astrophysics Data System (ADS)
Lee, Dae-Hee
2016-07-01
We present a new design of a passive type RADFET reader with enhanced radiation sensitivity. Using a electostatic plate, we have applied a static electric field to the gate voltage, which impacts a positive biasing on the p-type MOSFET. The resultant effect shows that 1.8 times of radiation sensitivity increased when we measured the threshold voltage shift of the RADFET exposed to 30 krad irradiation. We discuss further about the characteristic changes of a RADFET according to the positive biasing on the gate voltage.
Active damping of the e-p instability at the Los Alamos Proton Storage Ring
NASA Astrophysics Data System (ADS)
Macek, R. J.; Assadi, S.; Byrd, J. M.; Deibele, C. E.; Henderson, S. D.; Lee, S. Y.; McCrady, R. C.; Pivi, M. F. T.; Plum, M. A.; Walbridge, S. B.; Zaugg, T. J.
2007-12-01
A prototype of an analog, transverse (vertical) feedback system for active damping of the two-stream (e-p) instability has been developed and successfully tested at the Los Alamos Proton Storage Ring (PSR). This system was able to improve the instability threshold by approximately 30% (as measured by the change in RF buncher voltage at instability threshold). The feedback system configuration, setup procedures, and optimization of performance are described. Results of several experimental tests of system performance are presented including observations of instability threshold improvement and grow-damp experiments, which yield estimates of instability growth and damping rates. A major effort was undertaken to identify and study several factors limiting system performance. Evidence obtained from these tests suggests that performance of the prototype was limited by higher instability growth rates arising from beam leakage into the gap at lower RF buncher voltage and the onset of instability in the horizontal plane, which had no feedback.
Furong, Liu; Shengtian, L I
2016-05-25
To investigate patterns of action potential firing in cortical heurons of neonatal mice and their electrophysiological properties. The passive and active membrane properties of cortical neurons from 3-d neonatal mice were observed by whole-cell patch clamp with different voltage and current mode. Three patterns of action potential firing were identified in response to depolarized current injection. The effects of action potential firing patterns on voltage-dependent inward and outward current were found. Neurons with three different firing patterns had different thresholds of depolarized current. In the morphology analysis of action potential, the three type neurons were different in rise time, duration, amplitude and threshold of the first action potential evoked by 80 pA current injection. The passive properties were similar in three patterns of action potential firing. These results indicate that newborn cortical neurons exhibit different patterns of action potential firing with different action potential parameters such as shape and threshold.
Voltage and pace-capture mapping of linear ablation lesions overestimates chronic ablation gap size.
O'Neill, Louisa; Harrison, James; Chubb, Henry; Whitaker, John; Mukherjee, Rahul K; Bloch, Lars Ølgaard; Andersen, Niels Peter; Dam, Høgni; Jensen, Henrik K; Niederer, Steven; Wright, Matthew; O'Neill, Mark; Williams, Steven E
2018-04-26
Conducting gaps in lesion sets are a major reason for failure of ablation procedures. Voltage mapping and pace-capture have been proposed for intra-procedural identification of gaps. We aimed to compare gap size measured acutely and chronically post-ablation to macroscopic gap size in a porcine model. Intercaval linear ablation was performed in eight Göttingen minipigs with a deliberate gap of ∼5 mm left in the ablation line. Gap size was measured by interpolating ablation contact force values between ablation tags and thresholding at a low force cut-off of 5 g. Bipolar voltage mapping and pace-capture mapping along the length of the line were performed immediately, and at 2 months, post-ablation. Animals were euthanized and gap sizes were measured macroscopically. Voltage thresholds to define scar were determined by receiver operating characteristic analysis as <0.56 mV (acutely) and <0.62 mV (chronically). Taking the macroscopic gap size as gold standard, error in gap measurements were determined for voltage, pace-capture, and ablation contact force maps. All modalities overestimated chronic gap size, by 1.4 ± 2.0 mm (ablation contact force map), 5.1 ± 3.4 mm (pace-capture), and 9.5 ± 3.8 mm (voltage mapping). Error on ablation contact force map gap measurements were significantly less than for voltage mapping (P = 0.003, Tukey's multiple comparisons test). Chronically, voltage mapping and pace-capture mapping overestimated macroscopic gap size by 11.9 ± 3.7 and 9.8 ± 3.5 mm, respectively. Bipolar voltage and pace-capture mapping overestimate the size of chronic gap formation in linear ablation lesions. The most accurate estimation of chronic gap size was achieved by analysis of catheter-myocardium contact force during ablation.
DiFranco, Marino; Quinonez, Marbella
2012-01-01
A two-microelectrode voltage clamp and optical measurements of membrane potential changes at the transverse tubular system (TTS) were used to characterize delayed rectifier K currents (IKV) in murine muscle fibers stained with the potentiometric dye di-8-ANEPPS. In intact fibers, IKV displays the canonical hallmarks of KV channels: voltage-dependent delayed activation and decay in time. The voltage dependence of the peak conductance (gKV) was only accounted for by double Boltzmann fits, suggesting at least two channel contributions to IKV. Osmotically treated fibers showed significant disconnection of the TTS and displayed smaller IKV, but with similar voltage dependence and time decays to intact fibers. This suggests that inactivation may be responsible for most of the decay in IKV records. A two-channel model that faithfully simulates IKV records in osmotically treated fibers comprises a low threshold and steeply voltage-dependent channel (channel A), which contributes ∼31% of gKV, and a more abundant high threshold channel (channel B), with shallower voltage dependence. Significant expression of the IKV1.4 and IKV3.4 channels was demonstrated by immunoblotting. Rectangular depolarizing pulses elicited step-like di-8-ANEPPS transients in intact fibers rendered electrically passive. In contrast, activation of IKV resulted in time- and voltage-dependent attenuations in optical transients that coincided in time with the peaks of IKV records. Normalized peak attenuations showed the same voltage dependence as peak IKV plots. A radial cable model including channels A and B and K diffusion in the TTS was used to simulate IKV and average TTS voltage changes. Model predictions and experimental data were compared to determine what fraction of gKV in the TTS accounted simultaneously for the electrical and optical data. Best predictions suggest that KV channels are approximately equally distributed in the sarcolemma and TTS membranes; under these conditions, >70% of IKV arises from the TTS. PMID:22851675
Yokokawa, Miki; Desjardins, Benoit; Crawford, Thomas; Good, Eric; Morady, Fred; Bogun, Frank
2013-01-08
The purpose of this study was to assess the determinants of ventricular tachycardia (VT) recurrence in patients who underwent VT ablation for post-infarction VT. The factors that predict recurrence of VT after catheter ablation in patients with prior infarctions are not well described. Catheter ablation was performed in 98 consecutive patients (88 males [90%]; mean age 67 ± 10 years; ejection fraction 27 ± 13%) with post-infarction VT. Electrograms from the implantable cardioverter-defibrillator were analyzed, and VTs were classified as clinical, nonclinical, or new clinical. A total of 725 VTs were induced during the ablation procedure. All VTs were targeted. In 76 patients, 105 clinical VTs were inducible. Critical sites were identified with entrainment mapping and pace-mapping (≥10 of 12 matching leads) for 75 of 105 clinical VTs (71%) and for 278 of 620 nonclinical VTs (45%). Post-ablation, the clinical VT was not inducible in any patient, and all VTs were rendered noninducible in 63% of the patients. Over a mean follow-up period of 35 ± 23 months, 65 of 98 patients (66%) had no recurrent VTs and 33 (34%) had VT recurrence. A new VT occurred in 26 of 33 patients (79%), and a prior clinical VT recurred in 7 patients (21%). Patients with recurrent VT had a larger scar area as assessed by electroanatomic mapping compared with patients without recurrent VTs (93 ± 40 cm(2) vs. 69 ± 30 cm(2); p = 0.002). In patients with repeat procedures, the majority of inducible VTs for which a critical area could be identified were at a distance of 6 ± 3 mm to the prior ablation lesions. Patients with recurrent VTs have a larger scar as assessed by electroanatomic mapping. Most recurrent VTs were new, and the majority of these VTs were mapped to the vicinity of prior ablation lesions in patients with repeat procedures. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Highly symmetric D-brane-anti-D-brane effective actions
NASA Astrophysics Data System (ADS)
Hatefi, Ehsan
2017-09-01
The entire S-matrix elements of four, five and six point functions of D-brane-anti D-brane system are explored. To deal with symmetries of string amplitudes as well as their all order α ' corrections we first address a four point function of one closed string Ramond-Ramond (RR) and two real tachyons on the world volume of brane-anti brane system. We then focus on symmetries of string theory as well as universal tachyon expansion to achieve both string and effective field theory of an RR and three tachyons where the complete algebraic analysis for the whole S-matrix < {V}_{C^{-1}}{V}_{T^{-1}}{V}_{T^0}{V}_{T^0}> was also revealed. Lastly, we employ all the conformal field theory techniques to < {V}_{C^{-1}}{V}_{T^{-1}}{V}_{T^0}{V}_{T^0}{V}_{T^0}> , working out with symmetries of theory and find out the expansion for the amplitude to be able to precisely discover all order singularity structures of D-brane-anti-D-brane effective actions of string theory. Various remarks about the so called generalized Veneziano amplitude and new string couplings are elaborated as well.
2015-01-01
The Virtual Teacher paradigm, a version of the Human Dynamic Clamp (HDC), is introduced into studies of learning patterns of inter-personal coordination. Combining mathematical modeling and experimentation, we investigate how the HDC may be used as a Virtual Teacher (VT) to help humans co-produce and internalize new inter-personal coordination pattern(s). Human learners produced rhythmic finger movements whilst observing a computer-driven avatar, animated by dynamic equations stemming from the well-established Haken-Kelso-Bunz (1985) and Schöner-Kelso (1988) models of coordination. We demonstrate that the VT is successful in shifting the pattern co-produced by the VT-human system toward any value (Experiment 1) and that the VT can help humans learn unstable relative phasing patterns (Experiment 2). Using transfer entropy, we find that information flow from one partner to the other increases when VT-human coordination loses stability. This suggests that variable joint performance may actually facilitate interaction, and in the long run learning. VT appears to be a promising tool for exploring basic learning processes involved in social interaction, unraveling the dynamics of information flow between interacting partners, and providing possible rehabilitation opportunities. PMID:26569608
Lerma, Claudia; Wessel, Niels; Schirdewan, Alexander; Kurths, Jürgen; Glass, Leon
2008-07-01
The objective was to determine the characteristics of heart rate variability and ventricular arrhythmias prior to the onset of ventricular tachycardia (VT) in patients with an implantable cardioverter defibrillator (ICD). Sixty-eight beat-to-beat time series from 13 patients with an ICD were analyzed to quantify heart rate variability and ventricular arrhythmias. The episodes of VT were classified in one of two groups depending on whether the sinus rate in the 1 min preceding the VT was greater or less than 90 beats per minute. In a subset of patients, increased heart rate and reduced heart rate variability was often observed up to 20 min prior to the VT. There was a non-significant trend to higher incidence of premature ventricular complexes (PVCs) before VT compared to control recordings. The patterns of the ventricular arrhythmias were highly heterogeneous among different patients and even within the same patient. Analysis of the changes of heart rate and heart rate variability may have predictive value about the onset of VT in selected patients. The patterns of ventricular arrhythmia could not be used to predict onset of VT in this group of patients.
Kostrubiec, Viviane; Dumas, Guillaume; Zanone, Pier-Giorgio; Kelso, J A Scott
2015-01-01
The Virtual Teacher paradigm, a version of the Human Dynamic Clamp (HDC), is introduced into studies of learning patterns of inter-personal coordination. Combining mathematical modeling and experimentation, we investigate how the HDC may be used as a Virtual Teacher (VT) to help humans co-produce and internalize new inter-personal coordination pattern(s). Human learners produced rhythmic finger movements whilst observing a computer-driven avatar, animated by dynamic equations stemming from the well-established Haken-Kelso-Bunz (1985) and Schöner-Kelso (1988) models of coordination. We demonstrate that the VT is successful in shifting the pattern co-produced by the VT-human system toward any value (Experiment 1) and that the VT can help humans learn unstable relative phasing patterns (Experiment 2). Using transfer entropy, we find that information flow from one partner to the other increases when VT-human coordination loses stability. This suggests that variable joint performance may actually facilitate interaction, and in the long run learning. VT appears to be a promising tool for exploring basic learning processes involved in social interaction, unraveling the dynamics of information flow between interacting partners, and providing possible rehabilitation opportunities.
Ran, Yang; Su, Rongtao; Ma, Pengfei; Wang, Xiaolin; Zhou, Pu; Si, Lei
2016-05-10
We present a new quantitative index of standard deviation to measure the homogeneity of spectral lines in a fiber amplifier system so as to find the relation between the stimulated Brillouin scattering (SBS) threshold and the homogeneity of the corresponding spectral lines. A theoretical model is built and a simulation framework has been established to estimate the SBS threshold when input spectra with different homogeneities are set. In our experiment, by setting the phase modulation voltage to a constant value and the modulation frequency to different values, spectral lines with different homogeneities can be obtained. The experimental results show that the SBS threshold increases negatively with the standard deviation of the modulated spectrum, which is in good agreement with the theoretical results. When the phase modulation voltage is confined to 10 V and the modulation frequency is set to 80 MHz, the standard deviation of the modulated spectrum equals 0.0051, which is the lowest value in our experiment. Thus, at this time, the highest SBS threshold has been achieved. This standard deviation can be a good quantitative index in evaluating the power scaling potential in a fiber amplifier system, which is also a design guideline in suppressing the SBS to a better degree.
Hoffmayer, Kurt S; Bhave, Prashant D; Marcus, Gregory M; James, Cynthia A; Tichnell, Crystal; Chopra, Nagesh; Moxey, Laura; Krahn, Andrew D; Dixit, Sanjay; Stevenson, William; Calkins, Hugh; Badhwar, Nitish; Gerstenfeld, Edward P; Scheinman, Melvin M
2013-04-01
Ventricular arrhythmias in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) and idiopathic ventricular tachycardia (VT) can share a left bundle branch block/inferior axis morphology. We previously reported electrocardiogram characteristics during outflow tract ventricular arrhythmias that helped distinguish VT related to ARVD/C from idiopathic VT. To prospectively validate these criteria. We created a risk score by using a derivation cohort. Two experienced electrophysiologists blinded to the diagnosis prospectively scored patients with VT/premature ventricular contractions (PVCs) with left bundle branch block/inferior axis pattern in a validation cohort of 37 ARVD/C tracings and 49 idiopathic VT tracings. All patients with ARVD/C had their diagnosis confirmed based on the revised task force criteria. Patients with idiopathic VT were selected based on structurally normal hearts with documented right ventricular outflow tract VT successfully treated with ablation. The scoring system provides 3 points for sinus rhythm anterior T-wave inversions in leads V1-V3 and during ventricular arrhythmia: 2 points for QRS duration in lead I≥120 ms, 2 points for QRS notching, and 1 point for precordial transition at lead V5 or later. A score of 5 or greater was able to correctly distinguish ARVD/C from idiopathic VT 93% of the time, with a sensitivity of 84%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 91%. We describe a simple scoring algorithm that uses 12-lead electrocardiogram characteristics to effectively distinguish right ventricular outflow tract arrhythmias originating from patients with ARVD/C versus patients with idiopathic VT. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Tingay, David G; Polglase, Graeme R; Bhatia, Risha; Berry, Clare A; Kopotic, Robert J; Kopotic, Clinton P; Song, Yong; Szyld, Edgardo; Jobe, Alan H; Pillow, J Jane
2015-04-01
Support of the mechanically complex preterm lung needs to facilitate aeration while avoiding ventilation heterogeneities: whether to achieve this gradually or quickly remains unclear. We compared the effect of gradual vs. constant tidal inflations and a pressure-limited sustained inflation (SI) at birth on gas exchange, lung mechanics, gravity-dependent lung volume distribution, and lung injury in 131-day gestation preterm lambs. Lambs were resuscitated with either 1) a 20-s, 40-cmH2O pressure-limited SI (PressSI), 2) a gradual increase in tidal volume (Vt) over 5-min from 3 ml/kg to 7 ml/kg (IncrVt), or 3) 7 ml/kg Vt from birth. All lambs were subsequently ventilated for 15 min with 7 ml/kg Vt with the same end-expiratory pressure. Lung mechanics, gas exchange and spatial distribution of end-expiratory volume (EEV), and tidal ventilation (electrical impedance tomography) were recorded regularly. At 15 min, early mRNA tissue markers of lung injury were assessed. The IncrVt group resulted in greater tissue hysteresivity at 5 min (P = 0.017; two-way ANOVA), higher alveolar-arterial oxygen difference from 10 min (P < 0.01), and least uniform gravity-dependent distribution of EEV. There were no other differences in lung mechanics between groups, and the PressSI and 7 ml/kg Vt groups behaved similarly throughout. EEV was more uniformly distributed, but Vt least so, in the PressSI group. There were no differences in mRNA markers of lung injury. A gradual increase in Vt from birth resulted in less recruitment of the gravity-dependent lung with worse oxygenation. There was no benefit of a SI at birth over mechanical ventilation with 7 ml/kg Vt. Copyright © 2015 the American Physiological Society.
Blouin, D; Topping, C; Moore, S; Stiell, I; Afilalo, M
2001-09-01
The American Heart Association protocols for use of automated external defibrillators (AEDs) recommend that a rhythm analysis be done immediately after each defibrillation attempt. However, shock is often followed by electrical silence or marginally organized electrical activity before ventricular fibrillation (VF) or ventricular tachycardia (VT) recurs. The optimal timing of postshock analysis for identification of recurrent VF/VT is unknown. This study examines the time to recurrence of VF/VT after a defibrillation attempt with AED. Over an 18-month period, all tapes from patients with out-of-hospital cardiac arrest who received shocks at least once with an AED were screened for recurrent VF/VT. All cases come from a single emergency medical services system providing basic life support, defibrillation with AED, and intubation with an esophageal-tracheal twin-lumen airway device (Combitube) for a population of 633,511 individuals. Pediatric and traumatic cases were excluded. When VF/VT recurred within 3 minutes of the defibrillation attempt, rhythm strips were printed and included in the study. Two cardiology fellows, blinded to the study objectives, measured the time from defibrillation to recurrent VF/VT for each strip. Over the study period, 222 tapes from 96 patients met the inclusion criteria. Only 44 (20%) occurrences of VF/VT had recurred within 6 seconds of defibrillation, 162 (73%) at 60 seconds, and 200 (90%) at 90 seconds. Eighty percent of VF/VT recurred more than 6 seconds after defibrillation and were missed when using current American Heart Association AED protocols. Subsequent analysis should be postponed until at least 30 seconds after defibrillation. Performing 30 seconds of chest compressions after defibrillation before subsequent AED rhythm analysis would increase AED identification of VF/VT to 52%.
Kapel, Gijsbert F L; Reichlin, Tobias; Wijnmaalen, Adrianus P; Piers, Sebastiaan R D; Holman, Eduard R; Tedrow, Usha B; Schalij, Martin J; Stevenson, William G; Zeppenfeld, Katja
2015-02-01
Ventricular tachycardia (VT) is an important cause of late morbidity and mortality in repaired congenital heart disease. The substrate often includes anatomic isthmuses that can be transected by radiofrequency catheter ablation similar to isthmus block for atrial flutter. This study evaluates the long-term efficacy of isthmus block for treatment of re-entry VT in adults with repaired congenital heart disease. Thirty-four patients (49±13 years; 74% male) with repaired congenital heart disease who underwent radiofrequency catheter ablation of VT in 2 centers were included. Twenty-two (65%) had a preserved left and right ventricular function. Patients were inducible for 1 (interquartile range, 1-2) VT, median cycle length: 295 ms (interquartile range, 242-346). Ablation aimed to transect anatomic isthmuses containing VT re-entry circuit isthmuses. Procedural success was defined as noninducibility of any VT and transection of the anatomic isthmus and was achieved in 25 (74%) patients. During long-term follow-up (46±29 months), all patients with procedural success (18/25 with internal cardiac defibrillators) were free of VT recurrence but 7 of 18 experienced internal cardiac defibrillator-related complications. One patient with procedural success and depressed cardiac function received an internal cardiac defibrillator shock for ventricular fibrillation. None of the 18 patients (12/18 with internal cardiac defibrillators) with complete success and preserved cardiac function experienced any ventricular arrhythmia. In contrast, VT recurred in 4 of 9 patients without procedural success. Four patients died from nonarrhythmic causes. In patients with repaired congenital heart disease with preserved ventricular function and isthmus-dependent re-entry, VT isthmus ablation can be curative. © 2014 American Heart Association, Inc.
A meta-analysis of manual versus remote magnetic navigation for ventricular tachycardia ablation.
Turagam, Mohit K; Atkins, Donita; Tung, Roderick; Mansour, Moussa; Ruskin, Jeremy; Cheng, Jie; Di Biase, Luigi; Natale, Andrea; Lakkireddy, Dhanunjaya
2017-09-01
There are limited studies on the safety and efficacy of remote magnetic navigation (RMN) versus manual navigation (MAN) in ventricular tachycardia (VT) ablation. A comprehensive literature search was performed using the keywords VT ablation, stereotaxis, RMN and MAN in Pubmed, Ebsco, Web of Science, Cochrane, and Google scholar databases. The analysis included seven studies (one randomized, three prospective observational, and three retrospective) including 779 patients [both structural heart disease (SHD) and idiopathic VT] comparing RMN (N = 433) and MAN (N = 339) in VT ablation. The primary end point of long-term VT recurrence was significantly lower with RMN (OR 0.61, 95% CI 0.44-0.85, p = 0.003) compared with MAN. Other end points of acute procedural success (OR 2.13, 95% CI 1.40-3.23, p = 0.0004) was significantly higher with RMN compared with MAN. Fluoroscopy [mean difference -10.42, 95% CI -12.7 to -8.1, p < 0.0001], procedural time [mean difference -9.79, 95% CI -19.27 to -0.3, p = 0.04] and complications (OR 0.35, 95% CI 0.17-0.74, p = 0.0006) were also significantly lower in RMN when compared with MAN. In a subgroup analysis SHD, there was no significant difference in VT recurrence or acute procedural success with RMN vs. MAN. In idiopathic VT, RMN significantly increased acute procedural success with no difference in VT recurrence. The results demonstrate that RMN is safe and effective when compared with MAN in patients with both SHD and idiopathic VT undergoing catheter ablation. Further prospective studies are needed to further verify the safety and efficacy of RMN.
Fan, Shengxian; Ni, Xiaodong; Wang, Jian; Zhang, Yongliang; Tao, Shen; Kong, Wencheng; Li, Yousheng; Li, Jieshou
2017-04-01
Previous studies have noticed the high incidence of suboptimal vitamin D (VtD) status and bone loss in short bowel syndrome (SBS) with parenteral nutrition (PN) dependence. However, limited data have focused on adult SBS without PN dependence. Therefore, our objective was to investigate the incidence and risk factors of suboptimal VtD status and bone loss in adult SBS even after weaning off PN. We performed a prospective study of 60 adult patients with SBS. Serum 25-hydroxyvitamin D (25-OHD) was measured by radioimmunoassay. Bone mineral density (BMD) was measured using dual-energy x-ray absorptiometry (DEXA). Medical records and various laboratory parameters were collected in all participants. Suboptimal VtD status was identified in all individuals, including 3 (5.0%) with VtD insufficiency and 57 (95.0%) with VtD deficiency. Residual small bowel length (B, 0.072, P = .001) and duration of SBS (B, -0.066, P = .020) were both significantly correlated with suboptimal VtD levels. Overall, only 2 patients presented a normal BMD; osteopenia and osteoporosis were noted in 41 (68.3%) and 17 (28.3%) individuals, respectively. Low 25-OHD concentration was associated with a decreased BMD (B, 0.065, P = .029). There were no other demographic characteristics or clinical examinations associated with suboptimal VtD levels and bone loss. Suboptimal VtD status and bone loss were common in adult SBS even after weaning off PN. Despite routine oral VtD supplementation, most patients did not achieve satisfactory status. This emphasizes the critical importance of routine surveillance of 25-OHD and BMD, as well as consideration of alternative methods of supplementation after weaning off PN.
Wilke, Carolina F; Ramos, Guilherme P; Pacheco, Diogo A S; Santos, Weslley H M; Diniz, Mateus S L; Gonçalves, Gabriela G P; Marins, João C B; Wanner, Samuel P; Silami-Garcia, Emerson
2016-08-01
Wilke, CF, Ramos, GP, Pacheco, DAS, Santos, WHM, Diniz, MSL, Gonçalves, GGP, Marins, JCB, Wanner, SP, and Silami-Garcia, E. Metabolic demand and internal training load in technical-tactical training sessions of professional futsal players. J Strength Cond Res 30(8): 2330-2340, 2016-The aim of the study was to characterize aspects of technical-tactical training sessions of a professional futsal team. We addressed 4 specific aims: characterize the metabolic demands and intensity of these training sessions, compare the training intensity among players of different positions, compare the intensity of different futsal-specific activities (4 × 4, 6 × 4, and match simulation), and investigate the association between an objective (training impulse; TRIMP) and a subjective method (session rating of perceived exertion; sRPE) of measuring a player's internal training load. Twelve top-level futsal players performed an incremental exercise to determine their maximal oxygen consumption, maximal heart rate (HRmax), ventilatory threshold (VT), and respiratory compensation point (RCP). Each player's HR and RPE were measured and used to calculate energy expenditure, TRIMP, and sRPE during 37 training sessions over 8 weeks. The average intensity was 74 ± 4% of HRmax, which corresponded to 9.3 kcal·min. The players trained at intensities above the RCP, between the RCP and VT and below the VT for 20 ± 8%, 28 ± 6%, and 51 ± 10% of the session duration, respectively. Wingers, defenders, and pivots exercised at a similar average intensity but with different intensity distributions. No difference in intensity was found between the 3 typical activities. A strong correlation between the average daily TRIMP and sRPE was observed; however, this relationship was significant for only 4 of 12 players, indicating that sRPE is a useful tool for monitoring training loads but that it should be interpreted for each player individually rather than collectively.
Espada, Mario C; Reis, Joana F; Almeida, Tiago F; Bruno, Paula M; Vleck, Veronica E; Alves, Francisco B
2015-10-01
The purpose of this study was to understand the ventilatory and physiological responses immediately below and above the maximal lactate steady-state (MLSS) velocity and to determine the relationship of oxygen uptake (VO2) kinetics parameters with performance, in swimmers. Competitive athletes (N = 12) completed in random order and on different days a 400-m all-out test, an incremental step test comprising 5 × 250- and 1 × 200-m stages and 30 minutes at a constant swimming velocity (SV) at 87.5, 90, and 92.5% of the maximal aerobic velocity for MLSS velocity (MLSSv) determination. Two square-wave transitions of 500 m, 2.5% above and below the MLSSv were completed to determine VO2 on-kinetics. End-exercise VO2 at 97.5 and 102.5% of MLSSv represented, respectively, 81 and 97% of VO2max; the latter was not significantly different from maximal VO2 (VO2max). The VO2 at MLSSv (49.3 ± 9.2 ml·kg(-1)·min(-1)) was not significantly different from the second ventilatory threshold (VT2) (51.3 ± 7.6 ml·kg(-1)·min(-1)). The velocity associated with MLSS seems to be accurately estimated by the SV at VT2 (vVT2), and vVO2max also seems to be estimated with accuracy from the central 300-m mean velocity of a 400-m trial, indicators that represent a helpful tool for coaches. The 400-m swimming performance (T400) was correlated with the time constant of the primary phase VO2 kinetics (τp) at 97.5% MLSSv, and T800 was correlated with τp in both 97.5 and 102.5% of MLSSv. The assessment of the VO2 kinetics in swimming can help coaches to build training sets according to a swimmer's individual physiological response.
Physiologic responses during indoor cycling.
Battista, Rebecca A; Foster, Carl; Andrew, Jessica; Wright, Glenn; Lucia, Alejandro; Porcari, John P
2008-07-01
During the last decade, there has been active interest in indoor cycling (e.g., spinning) as a method of choreographed group exercise. Recent studies have suggested that exercise intensity during indoor cycling may be quite high and may transiently exceed Vo2max. This study sought to confirm these findings, as the apparent high intensity of indoor cycling has implications for both the efficacy and the risk of indoor cycling as an exercise method. Twenty healthy female students performed an incremental exercise test to define Vo2max and performed 2 videotaped indoor exercise classes lasting 45 minutes and 35 minutes. Vo2, heart rate (HR), and rating of perceived exertion (RPE) were measured during the indoor cycling classes, with Vo2 data integrated in 30-second intervals. The mean %Vo2max during the indoor cycling classes was modest (74 +/- 14% Vo2max and 66 +/- 14%Vo2max, respectively). However, 52% and 35% of the time during the 45- and 35-minute classes was spent at intensities greater than the ventilatory threshold (VT). The HR response indicated that 35% and 38% of the session time was above the HR associated with VT. In 10 of the 40 exercise sessions, there were segments in which the momentary Vo2 exceeded Vo2max observed during incremental testing, and the cumulative time with exercise intensity greater than Vo2max ranged from 0.5 to 14.0 minutes. It can be concluded that although the intensity of indoor cycling in healthy, physically active women is moderate, there are frequent observations of transient values of Vo2 exceeding Vo2max, and a substantial portion of the exercise bouts at intensities greater than VT. As such, the data suggest that indoor cycling must be considered a high-intensity exercise mode of exercise training, which has implications for both efficacy and risk.
Fong, Shirley S M; Ng, Shamay S M; Cheng, Yoyo T Y; Wong, Janet Y H; Yu, Esther Y T; Chow, Gary C C; Chak, Yvonne T C; Chan, Ivy K Y; Zhang, Joni; Macfarlane, Duncan; Chung, Louisa M Y
2016-01-01
Objectives. To evaluate the effects of Ving Tsun (VT) martial art training on the upper extremity muscle strength and eye-hand coordination of middle-aged and older adults. Methods. This study used a nonequivalent pretest-posttest control group design. Forty-two community-dwelling healthy adults participated in the study; 24 (mean age ± SD = 68.5 ± 6.7 years) underwent VT training for 4 weeks (a supervised VT session twice a week, plus daily home practice), and 18 (mean age ± SD = 72.0 ± 6.7 years) received no VT training and acted as controls. Shoulder and elbow isometric muscle strength and eye-hand coordination were evaluated using the Lafayette Manual Muscle Test System and a computerized finger-pointing test, respectively. Results. Elbow extensor peak force increased by 13.9% (P = 0.007) in the VT group and the time to reach peak force decreased (9.9%) differentially in the VT group compared to the control group (P = 0.033). For the eye-hand coordination assessment outcomes, reaction time increased by 2.9% in the VT group and decreased by 5.3% in the control group (P = 0.002). Conclusions. Four weeks of VT training could improve elbow extensor isometric peak force and the time to reach peak force but not eye-hand coordination in community-dwelling middle-aged and older adults.
Márton, Virág; Zádori, János; Kozinszky, Zoltan; Keresztúri, Attila
2016-11-01
To evaluate whether vanishing twin (VT) pregnancies achieved by in vitro fertilization and intracytoplasmic sperm injection (IVF-ICSI) had a more adverse perinatal outcome than those after natural conception. Longitudinal, retrospective cohort study. Tertiary university hospital. Three hundred and six (78 after IVF-ICSI and 228 after natural conception) VT pregnancies over a 22-year period, with VT cases matched to primarily singleton controls. None. Obstetric and neonatal outcome data. The incidence of VT was statistically significantly higher after natural conception (18.2% of twins) than after IVF-ICSI (12.6% of twins). The odds of VT in pregnancies complicated with pregestational or gestational diabetes were disproportionally higher in IVF-ICSI cases than in spontaneously conceived VT pregnancies (adjusted odds ratio [AOR]: 0.80 vs. 3.10 and 1.00 vs. 1.07, respectively). Previous induced abortion (AOR 1.34) or second-trimester fetal loss (AOR 3.3) increased the risk of VT pregnancies after spontaneous conception. Gestational diabetes mellitus in both the previous (AOR 5.41) and the present (AOR 2.3) pregnancy as well as chronic maternal diseases (AOR 3.5) and placentation anomalies all represented independent risk factors for VT after IVF-ICSI. Vanishing twin pregnancies had a lower prevalence and a worse perinatal outcome after IVF-ICSI as compared with those of their spontaneously conceived counterparts. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
An open-label study of sodium oxybate (Xyrem®) in spasmodic dysphonia
Rumbach, Anna F.; Blitzer, Andrew; Frucht, Steven J.; Simonyan, Kristina
2016-01-01
Objective Spasmodic dysphonia (SD) is a task-specific laryngeal dystonia that affects speech production. Co-occurring voice tremor (VT) often complicates the diagnosis and clinical management of SD. Treatment of SD and VT is largely limited to botulinum toxin injections into laryngeal musculature; other pharmacological options are not sufficiently developed. Study Design and Methods We conducted an open-label study in 23 SD and 22 SD/VT patients to examine the effects of sodium oxybate (Xyrem®), an oral agent with therapeutic effects similar to those of alcohol in these patients. Blinded randomized analysis of voice and speech samples assessed symptom improvement before and after drug administration. Results Sodium oxybate significantly improved voice symptoms (p = 0.001) primarily by reducing the number of SD-characteristic voice breaks and severity of VT. Sodium oxybate further showed a trend for improving VT symptoms (p = 0.03) in a subset of patients who received successful botulinum toxin injections for the management of their SD symptoms. The drug’s effects were observed approximately 30–40 min after its intake and lasted about 3.5–4 hours. Conclusion Our study demonstrated that sodium oxybate reduced voice symptoms in 82.2% of alcohol-responsive SD patients both with and without co-occurring VT. Our findings suggest that the therapeutic mechanism of sodium oxybate in SD and SD/VT may be linked to that of alcohol and as such sodium oxybate might be beneficial for alcohol-responsive SD and SD/VT patients. PMID:27808415
Ng, Shamay S. M.; Cheng, Yoyo T. Y.; Yu, Esther Y. T.; Chow, Gary C. C.; Chak, Yvonne T. C.; Chan, Ivy K. Y.; Zhang, Joni; Macfarlane, Duncan
2016-01-01
Objectives. To evaluate the effects of Ving Tsun (VT) martial art training on the upper extremity muscle strength and eye-hand coordination of middle-aged and older adults. Methods. This study used a nonequivalent pretest-posttest control group design. Forty-two community-dwelling healthy adults participated in the study; 24 (mean age ± SD = 68.5 ± 6.7 years) underwent VT training for 4 weeks (a supervised VT session twice a week, plus daily home practice), and 18 (mean age ± SD = 72.0 ± 6.7 years) received no VT training and acted as controls. Shoulder and elbow isometric muscle strength and eye-hand coordination were evaluated using the Lafayette Manual Muscle Test System and a computerized finger-pointing test, respectively. Results. Elbow extensor peak force increased by 13.9% (P = 0.007) in the VT group and the time to reach peak force decreased (9.9%) differentially in the VT group compared to the control group (P = 0.033). For the eye-hand coordination assessment outcomes, reaction time increased by 2.9% in the VT group and decreased by 5.3% in the control group (P = 0.002). Conclusions. Four weeks of VT training could improve elbow extensor isometric peak force and the time to reach peak force but not eye-hand coordination in community-dwelling middle-aged and older adults. PMID:27525020
Self similarities in desalination dynamics and performance using capacitive deionization.
Ramachandran, Ashwin; Hemmatifar, Ali; Hawks, Steven A; Stadermann, Michael; Santiago, Juan G
2018-09-01
Charge transfer and mass transport are two underlying mechanisms which are coupled in desalination dynamics using capacitive deionization (CDI). We developed simple reduced-order models based on a mixed reactor volume principle which capture the coupled dynamics of CDI operation using closed-form semi-analytical and analytical solutions. We use the models to identify and explore self-similarities in the dynamics among flow rate, current, and voltage for CDI cell operation including both charging and discharging cycles. The similarity approach identifies the specific combination of cell (e.g. capacitance, resistance) and operational parameters (e.g. flow rate, current) which determine a unique effluent dynamic response. We here demonstrate self-similarity using a conventional flow between CDI (fbCDI) architecture, and we hypothesize that our similarity approach has potential application to a wide range of designs. We performed an experimental study of these dynamics and used well-controlled experiments of CDI cell operation to validate and explore limits of the model. For experiments, we used a CDI cell with five electrode pairs and a standard flow between (electrodes) architecture. Guided by the model, we performed a series of experiments that demonstrate natural response of the CDI system. We also identify cell parameters and operation conditions which lead to self-similar dynamics under a constant current forcing function and perform a series of experiments by varying flowrate, currents, and voltage thresholds to demonstrate self-similarity. Based on this study, we hypothesize that the average differential electric double layer (EDL) efficiency (a measure of ion adsorption rate to EDL charging rate) is mainly dependent on user-defined voltage thresholds, whereas flow efficiency (measure of how well desalinated water is recovered from inside the cell) depends on cell volumes flowed during charging, which is determined by flowrate, current and voltage thresholds. Results of experiments strongly support this hypothesis. Results show that cycle efficiency and salt removal for a given flowrate and current are maximum when average EDL and flow efficiencies are approximately equal. We further explored a range of CC operations with varying flowrates, currents, and voltage thresholds using our similarity variables to highlight trade-offs among salt removal, energy, and throughput performance. Copyright © 2018 Elsevier Ltd. All rights reserved.
Ultra-sensitive Hall sensors based on graphene encapsulated in hexagonal boron nitride
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dauber, Jan; Stampfer, Christoph; Peter Grünberg Institute
2015-05-11
The encapsulation of graphene in hexagonal boron nitride provides graphene on substrate with excellent material quality. Here, we present the fabrication and characterization of Hall sensor elements based on graphene boron nitride heterostructures, where we gain from high mobility and low charge carrier density at room temperature. We show a detailed device characterization including Hall effect measurements under vacuum and ambient conditions. We achieve a current- and voltage-related sensitivity of up to 5700 V/AT and 3 V/VT, respectively, outpacing state-of-the-art silicon and III/V Hall sensor devices. Finally, we extract a magnetic resolution limited by low frequency electric noise of less than 50more » nT/√(Hz) making our graphene sensors highly interesting for industrial applications.« less
NASA Astrophysics Data System (ADS)
Sun, Jia; Wan, Qing; Lu, Aixia; Jiang, Jie
2009-11-01
Battery drivable low-voltage SnO2-based paper thin-film transistors with a near-zero threshold voltage (Vth=0.06 V) gated by microporous SiO2 dielectric with electric-double-layer (EDL) effect are fabricated at room temperature. The operating voltage is found to be as low as 1.5 V due to the huge gate specific capacitance (1.34 μF/cm2 at 40 Hz) related to EDL formation. The subthreshold gate voltage swing and current on/off ratio is found to be 82 mV/decade and 2.0×105, respectively. The electron field-effect mobility is estimated to be 47.3 cm2/V s based on the measured gate specific capacitance at 40 Hz.
Tunneling contact IGZO TFTs with reduced saturation voltages
NASA Astrophysics Data System (ADS)
Wang, Longyan; Sun, Yin; Zhang, Xintong; Zhang, Lining; Zhang, Shengdong; Chan, Mansun
2017-04-01
We report a tunneling contact indium-gallium-zinc oxide (IGZO) thin film transistor (TFT) with a graphene interlayer technique in this paper. A Schottky junction is realized between a metal and IGZO with a graphene interlayer, leading to a quantum tunneling of the TFT transport in saturation regions. This tunneling contact enables a significant reduction in the saturation drain voltage Vdsat compared to that of the thermionic emission TFTs, which is usually equal to the gate voltage minus their threshold voltages. Measured temperature independences of the subthreshold swing confirm a transition from the thermionic emission to quantum tunneling transports depending on the gate bias voltages in the proposed device. The tunneling contact TFTs with the graphene interlayer have implications to reduce the power consumptions of certain applications such as the active matrix OLED display.
NASA Astrophysics Data System (ADS)
Smallwood, Jeremy; Swenson, David E.
2011-06-01
Evaluation of electrostatic performance of footwear and flooring in combination is necessary in applications such as electrostatic discharge (ESD) control in electronics manufacture, evaluation of equipment for avoidance of factory process electrostatic ignition risks and avoidance of electrostatic shocks to personnel in working environments. Typical standards use a walking test in which the voltage produced on a subject is evaluated by identification and measurement of the magnitude of the 5 highest "peaks" and "valleys" of the recorded voltage waveform. This method does not lend itself to effective analysis of the risk that the voltage will exceed a hazard threshold. This paper shows the advantages of voltage probability analysis and recommends that the method is adopted for use in future standards.
Current-voltage characteristics in organic field-effect transistors. Effect of interface dipoles
NASA Astrophysics Data System (ADS)
Sworakowski, Juliusz
2015-07-01
The role of polar molecules present at dielectric/semiconductor interfaces of organic field-effect transistors (OFETs) has been assessed employing the electrostatic model put forward in a recently published paper (Sworakowski et al., 2014). The interface dipoles create dipolar traps in the surface region of the semiconductor, their depths decreasing with the distance from the interface. This feature results in appearance of mobility gradients in the direction perpendicular to the dielectric/semiconductor interface, manifesting themselves in modification of the shapes of current-voltage characteristics. The effect may account for differences in carrier mobilities determined from the same experimental data using methods scanning different ranges of channel thicknesses (e.g., transconductances vs. transfer characteristics), differences between turn-on voltages and threshold voltages, and gate voltage dependence of mobility.
High Voltage Solar Array Arc Testing for a Direct Drive Hall Effect Thruster System
NASA Technical Reports Server (NTRS)
Schneider, Todd; Carruth, M. R., Jr.; Vaughn, J. A.; Jongeward, G. A.; Mikellides, I. G.; Ferguson, D.; Kerslake, T. W.; Peterson, T.; Snyder, D.; Hoskins, A.
2004-01-01
The deleterious effects of spacecraft charging are well known, particularly when the charging leads to arc events. The damage that results from arcing can severely reduce system lifetime and even cause critical system failures. On a primary spacecraft system such as a solar array, there is very little tolerance for arcing. Motivated by these concerns, an experimental investigation was undertaken to determine arc thresholds for a high voltage (200-500 V) solar array in a plasma environment. The investigation was in support of a NASA program to develop a Direct Drive Hall-Effect Thruster (D2HET) system. By directly coupling the solar array to a Hall-effect thruster, the D2HET program seeks to reduce mass, cost and complexity commonly associated with the power processing in conventional power systems. In the investigation, multiple solar array technologies and configurations were tested. The cell samples were biased to a negative voltage, with an applied potential difference between them, to imitate possible scenarios in solar array strings that could lead to damaging arcs. The samples were tested in an environment that emulated a low-energy, HET-induced plasma. Short duration trigger arcs as well as long duration sustained arcs were generated. Typical current and voltage waveforms associated with the arc events are presented. Arc thresholds are also defined in terms of voltage, current and power. The data will be used to propose a new, high-voltage (greater than 300 V) solar array design for which the likelihood of damage from arcing is minimal.
High-speed low-power voltage-programmed driving scheme for AMOLED displays
NASA Astrophysics Data System (ADS)
Xingheng, Xia; Weijing, Wu; Xiaofeng, Song; Guanming, Li; Lei, Zhou; Lirong, Zhang; Miao, Xu; Lei, Wang; Junbiao, Peng
2015-12-01
A new voltage-programmed driving scheme named the mixed parallel addressing scheme is presented for AMOLED displays, in which one compensation interval can be divided into the first compensation frame and the consequent N -1 post-compensation frames without periods of initialization and threshold voltage detection. The proposed driving scheme has the advantages of both high speed and low driving power due to the mixture of the pipeline technology and the threshold voltage one-time detection technology. Corresponding to the proposed driving scheme, we also propose a new voltage-programmed compensation pixel circuit, which consists of five TFTs and two capacitors (5T2C). In-Zn-O thin-film transistors (IZO TFTs) are used to build the proposed 5T2C pixel circuit. It is shown that the non-uniformity of the proposed pixel circuit is considerably reduced compared with that of the conventional 2T1C pixel circuit. The number of frames (N) preserved in the proposed driving scheme are measured and can be up to 35 with the variation of the OLED current remaining in an acceptable range. Moreover, the proposed voltage-programmed driving scheme can be more valuable for an AMOLED display with high resolution, and may also be applied to other compensation pixel circuits. Project supported by the State Key Development Program for Basic Research of China (No. 2015CB655000) the National Natural Science Foundation of China (Nos. 61204089, 61306099, 61036007, 51173049, U1301243), and the Fundamental Research Funds for the Central Universities (Nos. 2013ZZ0046, 2014ZZ0028).
Kim, Sung-Jin; Yokokawa, Ryuji; Takayama, Shuichi
2012-12-03
This paper reveals a critical limitation in the electro-hydraulic analogy between a microfluidic membrane-valve (μMV) and an electronic transistor. Unlike typical transistors that have similar on and off threshold voltages, in hydraulic μMVs, the threshold pressures for opening and closing are significantly different and can change, even for the same μMVs depending on overall circuit design and operation conditions. We explain, in particular, how the negative values of the closing threshold pressures significantly constrain operation of even simple hydraulic μMV circuits such as autonomously switching two-valve microfluidic oscillators. These understandings have significant implications in designing self-regulated microfluidic devices.
Method and Apparatus for Reducing the Vulnerability of Latches to Single Event Upsets
NASA Technical Reports Server (NTRS)
Shuler, Robert L., Jr. (Inventor)
2002-01-01
A delay circuit includes a first network having an input and an output node, a second network having an input and an output, the input of the second network being coupled to the output node of the first network. The first network and the second network are configured such that: a glitch at the input to the first network having a length of approximately one-half of a standard glitch time or less does not cause the voltage at the output of the second network to cross a threshold, a glitch at the input to the first network having a length of between approximately one-half and two standard glitch times causes the voltage at the output of the second network to cross the threshold for less than the length of the glitch, and a glitch at the input to the first network having a length of greater than approximately two standard glitch times causes the voltage at the output of the second network to cross the threshold for approximately the time of the glitch. The method reduces the vulnerability of a latch to single event upsets. The latch includes a gate having an input and an output and a feedback path from the output to the input of the gate. The method includes inserting a delay into the feedback path and providing a delay in the gate.
Method and Apparatus for Reducing the Vulnerability of Latches to Single Event Upsets
NASA Technical Reports Server (NTRS)
Shuler, Robert L., Jr. (Inventor)
2002-01-01
A delay circuit includes a first network having an input and an output node, a second network having an input and an output, the input of the second network being coupled to the output node of the first network. The first network and the second network are configured such that: a glitch at the input to the first network having a length of approximately one-half of a standard glitch time or less does not cause tile voltage at the output of the second network to cross a threshold, a glitch at the input to the first network having a length of between approximately one-half and two standard glitch times causes the voltage at the output of the second network to cross the threshold for less than the length of the glitch, and a glitch at the input to the first network having a length of greater than approximately two standard glitch times causes the voltage at the output of the second network to cross the threshold for approximately the time of the glitch. A method reduces the vulnerability of a latch to single event upsets. The latch includes a gate having an input and an output and a feedback path from the output to the input of the gate. The method includes inserting a delay into the feedback path and providing a delay in the gate.
NASA Astrophysics Data System (ADS)
Yao, Congwei; Chang, Zhengshi; Chen, Sile; Ma, Hengchi; Mu, Haibao; Zhang, Guan-Jun
2017-09-01
Dielectric barrier discharge (DBD) is widely applied in many fields, and the discharge characteristics of insert gas have been the research focus for years. In this paper, fluid models of atmospheric Ar and He DBDs driven by 22 kHz sinusoidal voltage are built to analyze their ignition processes. The contributions of different electron sources in ignition process are analyzed, including the direct ionization of ground state atom, stepwise ionization of metastable particles, and secondary electron emission from dielectric wall, and they play different roles in different discharge stages. The Townsend direct ionization coefficient of He is higher than Ar with the same electrical field intensity, which is the direct reason for the different ignition thresholds between He and Ar. Further, the electron energy loss per free electron produced in Ar and He DBDs is discussed. It is found that the total electron energy loss rate of Ar is higher than He when the same electrical field is applied. The excitation reaction of Ar consumes the major electron energy but cannot produce free electrons effectively, which is the essential reason for the higher ignition threshold of Ar. The computation results of He and Ar extinction voltages can be explained in the view of electron energy loss, as well as the experimental results of different extinction voltages between Ar/NH3 and He DBDs.
Towards highly stable polymer electronics (Conference Presentation)
NASA Astrophysics Data System (ADS)
Nikolka, Mark; Nasrallah, Iyad; Broch, Katharina; Sadhanala, Aditya; Hurhangee, Michael; McCulloch, Iain; Sirringhaus, Henning
2016-11-01
Due to their ease of processing, organic semiconductors are promising candidates for applications in high performance flexible displays and fast organic electronic circuitry. Recently, a lot of advances have been made on organic semiconductors exhibiting surprisingly high performance and carrier mobilities exceeding those of amorphous silicon. However, there remain significant concerns about their operational and environmental stability, particularly in the context of applications that require a very high level of threshold voltage stability, such as active-matrix addressing of organic light-emitting diode (OLED) displays. Here, we report a novel technique for dramatically improving the operational stress stability, performance and uniformity of high mobility polymer field-effect transistors by the addition of specific small molecule additives to the polymer semiconductor film. We demonstrate for the first time polymer FETs that exhibit stable threshold voltages with threshold voltage shifts of less than 1V when subjected to a constant current operational stress for 1 day under conditions that are representative for applications in OLED active matrix displays. The approach constitutes in our view a technological breakthrough; it also makes the device characteristics independent of the atmosphere in which it is operated, causes a significant reduction in contact resistance and significantly improves device uniformity. We will discuss in detail the microscopic mechanism by which the molecular additives lead to this significant improvement in device performance and stability.
Wiegand, U K; Zhdanov, A; Stammwitz, E; Crozier, I; Claessens, R J; Meier, J; Bos, R J; Bode, F; Potratz, J
1999-06-01
The aim of this multicenter study was to investigate the performance of a new cardiac pacemaker lead with a titanium nitride cathode coated with a copolymer membrane. In particular, the electrophysiological effect of steroid dissolved in this ion-exchange membrane was evaluated by randomized comparison. Ninety-five patients were randomized either to the 1450 T (n = 51) or the 1451 T ventricular lead (n = 45) and received telemeteral VVI(R) pacemakers with identical diagnostic features. Both leads were bipolar, were passively affixed, and had a porous titanium nitride tip with a surface area of 3.5 mm2. The only difference between the two electrodes was 13 micrograms of dexamethasone added to the 1450 Ts membrane coating. Voltage thresholds (VTH) at pulse durations of 0.25, 0.37, and 0.5 ms, lead impedance, and sensing thresholds were measured at discharge, 2 weeks, 1 month, 3 months, and 6 months after implantation. Mean amplitude and the slew rate from three telemetered intracardiac electrograms, chronaxie-rheobase product, and minimum energy consumption were calculated. After a 6-month follow-up, mean voltage thresholds of 0.65 +/- 0.20 V and 0.63 +/- 0.34 were achieved for the 1450 T lead and 1451 T lead, respectively. As a result, a VTH < 1.0 V was obtained in all patients with 1450 T electrodes and in 97.7% of patients with 1451 T leads after 6 months follow-up. In both electrodes, stable VTH was reached 2 weeks after implantation, and no transient rise in threshold was observed. No differences were observed between the steroid and the nonsteroid group in respect to VTH, chronaxie-rheobase product, minimum energy consumption, and potential amplitude and slew rate. In conclusion, safe and efficient pacing at low pulse amplitudes were achieved with both leads. The tip design, independently of the steroid additive, prevented any energy-consuming increases in the voltage threshold.
TH-CD-201-12: Preliminary Evaluation of Organic Field Effect Transistors as Radiation Detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Syme, A; Lin, H; Rubio-Sanchez, J
Purpose: To fabricate organic field effect transistors (OFETs) and evaluate their performance before and after exposure to ionizing radiation. To determine if OFETs have potential to function as radiation dosimeters. Methods: OFETs were fabricated on both Si/SiO{sub 2} wafers and flexible polymer substrates using standard processing techniques. Pentacene was used as the organic semiconductor material and the devices were fabricated in a bottom gate configuration. Devices were irradiated using an orthovoltage treatment unit (120 kVp x-rays). Threshold voltage values were measured with the devices in saturation mode and quantified as a function of cumulative dose. Current-voltage characteristics of the devicesmore » were measured using a Keithley 2614 SourceMeter SMU Instrument. The devices were connected to the reader but unpowered during irradiations. Results: Devices fabricated on Si/SiO2 wafers demonstrated excellent linearity (R{sup 2} > 0.997) with threshold voltages that ranged between 15 and 36 V. Devices fabricated on a flexible polymer substrate had substantially smaller threshold voltages (∼ 4 – 8 V) and slightly worse linearity (R{sup 2} > 0.98). The devices demonstrated excellent stability in I–V characteristics over a large number (>2000) cycles. Conclusion: OFETs have demonstrated excellent potential in radiation dosimetry applications. A key advantage of these devices is their composition, which can be substantially more tissue-equivalent at low photon energies relative to many other types of radiation detector. In addition, fabrication of organic electronics can employ techniques that are faster, simpler and cheaper than conventional silicon-based devices. These results support further development of organic electronic devices for radiation detection purposes. Funding Support, Disclosures, and Conflict of Interest: This work was funded by the Natural Sciences and Engineering Research Council of Canada.« less
Lorenzo, Daniel; Velluti, Julio C
2004-01-01
The noradrenergic modulation of neuronal properties has been described at different levels of the mammalian brain. Although the anatomical characteristics of the noradrenergic system are well known in reptiles, functional data are scarce. In our study the noradrenergic modulation of cortical electrogenesis in the turtle medial cortex was studied in vitro using a combination of field and intracellular recordings. Turtle EEG consists of a low voltage background interspersed by spontaneous large sharp waves (LSWs). Noradrenaline (NA, 5-40 microM) induced (or enhanced) the generation of LSWs in a dose-dependent manner. Pharmacological experiments suggest the participation of alpha and beta receptors in this effect. In medial cortex neurons NA induced a hyperpolarization of the resting potential and a decrease of input resistance. Both effects were observed also after TTX treatment. Noradrenaline increased the response of the cells to depolarizing pulses, resulting in an upward shift of the frequency/current relation. In most cells the excitability change was mediated by a decrease of the spike voltage threshold resulting in the reduction of the amount of depolarization needed to fire the cell (voltage threshold minus resting potential). As opposed to the mechanisms reported in mammalian neurons, no changes in the frequency adaptation or the post-train afterhyperpolarization were observed. The NA effects at the cellular level were not reproduced by noradrenergic agonists. Age- and species-dependent properties in the pharmacology of adrenergic receptors could be involved in this result. Cellular effects of NA in turtle cortex are similar to those described in mammals, although the increase in cellular excitability seems to be mediated by a different mechanism. Copyright 2004 S. Karger AG, Basel
A Vowel-Based Method for Vocal Tract Control in Clarinet Pedagogy
ERIC Educational Resources Information Center
González, Darleny; Payri, Blas
2017-01-01
Our review of scientific literature shows that the activity inside the clarinetist's vocal tract (VT) affects pitch and timbre, while also facilitating technical exercises. Clarinetists adapt their VT intuitively and, in some cases, may compensate an inadequate VT configuration through unnecessary pressure, resulting in technical blockage,…
Complete genome analysis of jasmine virus T from Jasminum sambac in China.
Tang, Yajun; Gao, Fangluan; Yang, Zhen; Wu, Zujian; Yang, Liang
2016-07-01
The genome of a potyvirus (isolate JaVT_FZ) recovered from jasmine (Jasminum sambac L.) showing yellow ringspot symptoms in Fuzhou, China, was sequenced. JaVT_FZ is closely related to seven other potyviruses with completely sequenced genomes, with which it shares 66-70 % nucleotide and 52-56 % amino acid sequence identity. However, the coat protein (CP) gene shares 82-92 % nucleotide and 90-97 % amino acid sequence identity with those of two partially sequenced potyviruses, named jasmine potyvirus T (JaVT-jasmine) and jasmine yellow mosaic potyvirus (JaYMV-India), respectively. This suggests that JaVT_FZ, JaVT-jasmine and JaYMV-India should be regarded as members of a single potyvirus species, for which the name "Jasmine virus T" has priority.
Modelling voltage sag mitigation using dynamic voltage restorer and analyzing power quality issue
NASA Astrophysics Data System (ADS)
Ismail, Nor Laili; Hidzir, Hizrin Dayana Mohd; Thanakodi, Suresh; Nazar, Nazatul Shiema Moh; Ibrahim, Pungut; Ali, Che Ku Muhammad Sabri Che Ku
2018-02-01
Power quality problem which are arise due to a fault or a pulsed load can have caused an interruption of critical load. The modern power systems are becoming more sensitive to the quality of the power supplied by the utility company. Voltage sags and swells, flicker, interruptions, harmonic distortion and other distortion to the sinusoidal waveform are the examples of the power quality problems. The most affected due to these problems is industrial customers who use a lot of sensitive equipment. There has suffered a huge loss to these problems. Resulting of broken or damage equipment if voltage sag exceeds the sensitive threshold of the equipment. Thus, device such as Static Synchronous Compensator (STATCOM) and Dynamic Voltage Restorer (DVR) has been created to solve this problem among users. DVR is a custom power device that most effective and efficient. This paper intended to report the DVR operations during voltage sag compensation.
Anatomy of Ag/Hafnia-Based Selectors with 10 10 Nonlinearity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Midya, Rivu; Wang, Zhongrui; Zhang, Jiaming
We developed a novel Ag/oxide-based threshold switching device with attractive features including ≈10 10 nonlinearity. Furthermore, in a high-resolution transmission electron microscopic analysis of the nanoscale crosspoint device it is suggested that elongation of an Ag nanoparticle under voltage bias followed by spontaneous reformation of a more spherical shape after power off, is responsible for the observed threshold switching.
Anatomy of Ag/Hafnia-Based Selectors with 10 10 Nonlinearity
Midya, Rivu; Wang, Zhongrui; Zhang, Jiaming; ...
2017-01-30
We developed a novel Ag/oxide-based threshold switching device with attractive features including ≈10 10 nonlinearity. Furthermore, in a high-resolution transmission electron microscopic analysis of the nanoscale crosspoint device it is suggested that elongation of an Ag nanoparticle under voltage bias followed by spontaneous reformation of a more spherical shape after power off, is responsible for the observed threshold switching.
Negative differential resistance in GaN nanocrystals above room temperature.
Chitara, Basant; Ivan Jebakumar, D S; Rao, C N R; Krupanidhi, S B
2009-10-07
Negative differential resistance (NDR) has been observed for the first time above room temperature in gallium nitride nanocrystals synthesized by a simple chemical route. Current-voltage characteristics have been used to investigate this effect through a metal-semiconductor-metal (M-S-M) configuration on SiO2. The NDR effect is reversible and reproducible through many cycles. The threshold voltage is approximately 7 V above room temperature.