Sample records for tibialis anterior tendon

  1. Is tibialis anterior tendon transfer effective for recurrent clubfoot?

    PubMed

    Gray, Kelly; Burns, Joshua; Little, David; Bellemore, Michael; Gibbons, Paul

    2014-02-01

    Tibialis anterior tendon transfer surgery forms a part of Ponseti management for children with congenital talipes equinovarus who, after initial correction, present with residual dynamic supination. Although retrospective studies support good outcomes, prospective longitudinal studies in this population are lacking. We assessed strength, plantar loading, ROM, foot alignment, function, satisfaction, and quality of life in patients with clubfoot that recurred after Ponseti casting who met indications for tibialis anterior tendon transfer surgery, and compared them with a group of patients with clubfoot treated with casting but whose deformity did not recur (therefore who were not indicated for tibialis anterior tendon transfer surgery). Twenty children with idiopathic congenital talipes equinovarus indicated for tibialis anterior tendon transfer surgery were recruited. Assessment at baseline (before surgery), and 3, 6, and 12 months (after surgery) included strength (hand-held dynamometry), plantar loading (capacitance transducer matrix platform), ROM (Dimeglio scale), foot alignment (Foot Posture Index(©)), function and satisfaction (disease-specific instrument for clubfoot), and quality of life (Infant Toddler Quality of Life Questionnaire™). Outcomes were compared with those of 12 age-matched children with congenital talipes equinovarus not indicated for tibialis anterior tendon transfer surgery. Followup was 100% in the control group and 95% (19 of 20) in the tibialis anterior transfer group. At baseline, the tibialis anterior tendon transfer group had a significantly worse eversion-to-inversion strength ratio, plantar loading, ROM, foot alignment, and function and satisfaction. At 3 months after surgery, eversion-to-inversion strength, plantar loading, and function and satisfaction were no longer different between groups. Improvements were maintained at 12 months after surgery (eversion-to-inversion strength mean difference, 8% body weight; 95% CI, -26% to 11

  2. Minimally invasive repair of the tibialis anterior tendon using a semitendinosus autograft.

    PubMed

    Michels, Frederick; Van Der Bauwhede, Jan; Oosterlinck, Dirk; Thomas, Sam; Guillo, Stéphane

    2014-03-01

    Ruptures of the tibialis anterior tendon are rare but can cause substantial functional deficiencies. The literature regarding the treatment of such injuries is very limited. Atraumatic ruptures often occur in the presence of an abnormal tendon structure, and retraction often makes end-to-end repair impossible. With traumatic lesions, the risk of developing both adhesions and scar tissue is high. This study assesses the results of a surgical reconstruction using the interposition of a semitendinosus tendon autograft in 12 patients. Three patients had a traumatic rupture, and 9 patients had an atraumatic rupture. In 8 patients, the procedure was carried out using a minimally invasive technique. The average postoperative American Orthopaedic Foot & Ankle Society (AOFAS) Ankle-Hindfoot score was 95.7 in the atraumatic group and 94.7 in the traumatic group. Active dorsiflexion was possible after 2 to 3 weeks. We believe that the interposition of a strong, healthy tendon facilitated healing and allowed early weight bearing. All patients had good recovery of dorsiflexion and gait. Repairing a ruptured tibialis anterior tendon using a semitendinosus autograft was a reliable technique and offered a good result. With the minimally invasive approach, there was no need to divide the extensor retinaculum, which we believe allowed faster recovery and reduced the risk of adhesions and wound healing problems. Level IV, retrospective case series.

  3. A systematic review of tibialis anterior tendon rupture treatments and outcomes.

    PubMed

    Christman-Skieller, Claudia; Merz, Michael K; Tansey, Joseph P

    2015-04-01

    Tibialis anterior (TA) tendon rupture is a relatively rare injury that has been documented primarily in case reports. This article is the first large systematic review of the literature on treatment techniques for subcutaneous rupture of TA tendons. Studies for review were identified through a PubMed search. Eligible studies involved cases of closed tendon rupture. Of the 87 cases in the study, 72 were treated with surgery, 15 with conservative measures. Mean age was 63.9 years (surgery group) and 72.4 years (conservative treatment group). Primary repair was used most often for newer injuries, autograft most often for older injuries. Operative repair of subcutaneous TA tendon rupture leads to successful outcomes in many patients. A surgeon who is deciding which operative technique to use for a patient should consider the age of the injury and the findings of intraoperative assessment for tendon necrosis.

  4. A Comparative Study of Clinical Outcomes and Second-Look Arthroscopic Findings between Remnant-Preserving Tibialis Tendon Allograft and Hamstring Tendon Autograft in Anterior Cruciate Ligament Reconstruction: Matched-Pair Design.

    PubMed

    Kim, You Keun; Ahn, Jong Hyun; Yoo, Jae Doo

    2017-12-01

    This study aimed to compare stability, functional outcome, and second-look arthroscopic findings after anterior cruciate ligament reconstruction between remnant-preserving tibialis tendon allograft and remnant-sacrificing hamstring tendon autograft. We matched two groups (remnant-preserving tibialis tendon allograft group and hamstring tendon autograft group) in terms of demographic characteristics, associated injury, and knee characteristics. Each group consisted of 25 patients. Operation time was longer in the remnant-preserving tibialis tendon allograft group, but there was no significant intergroup difference in stability, clinical outcome, and second-look arthroscopic findings. When an autograft is not feasible in anterior cruciate ligament reconstruction, the remnant-preserving technique can produce comparable results in terms of restoration of function, stability of the knee, and degree of synovium coverage at second-look arthroscopy compared to remnant-sacrificing hamstring autograft.

  5. Anatomical Footprint of the Tibialis Anterior Tendon: Surgical Implications for Foot and Ankle Reconstructions.

    PubMed

    Willegger, Madeleine; Seyidova, Nargiz; Schuh, Reinhard; Windhager, Reinhard; Hirtler, Lena

    2017-01-01

    This study aimed to analyze precisely the dimensions, shapes, and variations of the insertional footprints of the tibialis anterior tendon (TAT) at the medial cuneiform (MC) and first metatarsal (MT1) base. Forty-one formalin-fixed human cadaveric specimens were dissected. After preparation of the TAT footprint, standardized photographs were made and the following parameters were evaluated: the footprint length, width, area of insertion, dorsoplantar location, shape, and additional tendon slips. Twenty feet (48.8%) showed an equal insertion at the MC and MT1, another 20 feet (48.8%) had a wide insertion at the MC and a narrow insertion at the MT1, and 1 foot (2.4%) demonstrated a narrow insertion at the MC and a wide insertion at the MT1. Additional tendon slips inserting at the metatarsal shaft were found in two feet (4.8%). Regarding the dorsoplantar orientation, the footprints were located medial in 29 feet (70.7%) and medioplantar in 12 feet (29.3%). The most common shape at the MT1 base was the crescent type (75.6%) and the oval type at the MC (58.5%). The present study provided more detailed data on the dimensions and morphologic types of the tibialis anterior tendon footprint. The established anatomical data may allow for a safer surgical preparation and a more anatomical reconstruction.

  6. [Rupture of the tendon of the tibialis anterior muscle : Etiology, clinical symptoms and treatment].

    PubMed

    Waizy, H; Bouillon, B; Stukenborg-Colsman, C; Yao, D; Ettinger, S; Claassen, L; Plaass, C; Danniilidis, K; Arbab, D

    2017-12-01

    Ruptures of the tendon of the tibialis anterior muscle tend to occur in the context of degenerative impairments. This mainly affects the distal avascular portion of the tendon. Owing to the good compensation through the extensor hallucis longus and extensor digitorum muscles, diagnosis is often delayed. In addition to the clinical examination, magnetic resonance inaging (MRI) diagnostics are of particular importance, although damage or rupture of the tendon can also be demonstrated sonographically. Therapeutic measures include conservative or operative measures, depending on the clinical symptoms. Conservative stabilization of the ankle can be achieved by avoiding plantar flexion using a peroneal orthosis or an ankle-foot orthosis. Subsequent problems, such as metatarsalgia or overloading of the medial foot edge can be addressed by insoles or a corresponding shoe adjustment. An operative procedure is indicated when there is corresponding suffering due to pressure and functional impairment. The direct end-to-end reconstruction of the tendon is only rarely possible in cases of delayed diagnosis due to the degenerative situation and the retraction of the tendon stumps. Depending on the defect size and the tendon quality, various operative techniques, such as rotationplasty, free transplants or tendon transfer can be used.

  7. Functional Outcomes Following Anterior Transfer of the Tibialis Posterior Tendon for Foot Drop Secondary to Peroneal Nerve Palsy.

    PubMed

    Cho, Byung-Ki; Park, Kyoung-Jin; Choi, Seung-Myung; Im, Se-Hyuk; SooHoo, Nelson F

    2017-06-01

    This retrospective comparative study reports the practical function in daily and sports activities after tibialis posterior tendon transfer for foot drop secondary to peroneal nerve palsy. Seventeen patients were followed for a minimum of 3 years after tibialis posterior tendon transfer for foot drop secondary to peroneal nerve palsy. Matched controls were used to evaluate the level of functional restoration. Functional evaluations included American Orthopaedic Foot & Ankle Society (AOFAS) scores, Foot and Ankle Outcome Score (FAOS), Foot and Ankle Ability Measure (FAAM) scores, and isokinetic muscle strength test. Radiographic evaluation for the changes of postoperative foot alignment included Meary angle, calcaneal pitch angle, hindfoot alignment angle, and navicular height. Mean AOFAS, FAOS, and FAAM scores significantly improved from 65.1 to 86.2, 55.6 to 87.8, and 45.7 to 84.4 points at final follow-up, respectively. However, all functional evaluation scores were significantly lower as compared to the control group ( P < .001). Mean peak torque (60 degrees/sec) of ankle dorsiflexors, plantarflexors, invertors, and evertors at final follow-up were 7.1 (deficit ratio of 65.4%), 39.2, 9.8, and 7.3 Nm, respectively. These muscle strengths were significantly lower compared to the control group ( P < .001). No significant differences in radiographic measurements were found, and no patients presented with a postoperative flat foot deformity. One patient (5.9%) needed an ankle-foot orthosis for occupational activity. Anterior transfer of the tibialis posterior tendon appears to be an effective surgical option for paralytic foot drop secondary to peroneal nerve palsy. Although restoration of dorsiflexion strength postoperatively was about 33% of the normal ankle, function in daily activities and gait ability were satisfactorily improved. In addition, tibialis posterior tendon transfer demonstrated no definitive radiographic or clinical progression to postoperative flat

  8. A Comparative Outcome Study of Hamstring Versus Tibialis Anterior and Synthetic Grafts for Deltoid to Triceps Transfers.

    PubMed

    Dunn, Jennifer A; Mohammed, Khalid D; Beadel, Gordon P; Rothwell, Alastair G; Simcock, Jeremy W

    2017-10-01

    To assess elbow extension strength and complications after deltoid-triceps transfers using hamstring tendon graft compared with tibialis anterior and synthetic tendon grafts. A retrospective review of deltoid-triceps transfers in patients with tetraplegia performed between 1983 and 2014. Seventy-five people (136 arms) had surgery performed, with the majority undergoing simultaneous bilateral surgery (n = 61; 81%). Tibialis anterior tendon grafts were used in 68 arms, synthetic grafts in 23 arms, and hamstring tendon grafts in 45 arms. The average age at surgery was 31 years. Sixty-three arms (46%) were assessed between 12 and 24 months after surgery. Seventy percent of the group (n = 54) were able to extend their elbow against gravity (grade 3 of 5 or greater) following surgery. Seventy-nine percent of those with hamstring grafts achieved grade 3 of 5 or more compared with 77% with tibialis anterior and 33% with synthetic grafts. There was a statistically significant difference in postsurgery elbow extension between the tibialis anterior group and the synthetic graft group and the hamstring and the synthetic graft group but not between the tibialis anterior and the hamstring group. Complications occurred in 19 arms (14%), the majority occurring immediately after surgery and associated with the wounds. The remaining complications were with the synthetic graft group in which dehiscence of the proximal attachment occurred in 30% of the arms. Autologous tendon grafting is associated with achievement of antigravity elbow extension in a greater proportion of individuals than with prosthetic grafting. Therapeutic IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  9. Response of tibialis anterior tendon to a chronic exposure of stretch-shortening cycles: age effects

    PubMed Central

    Ensey, James S; Hollander, Melinda S; Wu, John Z; Kashon, Michael L; Baker, Brent B; Cutlip, Robert G

    2009-01-01

    Background The purpose of the current study was to investigate the effects of aging on tendon response to repetitive exposures of stretch-shortening cycles (SSC's). Methods The left hind limb from young (3 mo, N = 4) and old (30 mo, N = 9) male Fisher 344 × Brown Norway rats were exposed to 80 maximal SSCs (60 deg/s, 50 deg range of motion) 3x/week for 4.5 weeks in vivo. After the last exposure, tendons from the tibialis anterior muscle were isolated, stored at -80°C, and then tested using a micro-mechanical testing machine. Deformation of each tendon was evaluated using both relative grip-to-grip displacements and reference marks via a video system. Results At failure, the young control tendons had higher strain magnitude than the young exposed (p < 0.01) and the old control tendons (p < .0001). Total load at inflection was affected by age only (p < 0.01). Old exposed and control tendons exhibited significantly higher loads at the inflection point than their young counterparts (p < 0.05 for both comparisons). At failure, the old exposed tendons carried higher loads than the young exposed tendons (p < 0.05). Stiffness was affected by age only at failure where the old tendons exhibited higher stiffness in both exposed and control tendons than their young counterparts (p < 0.05 and p < 0.01, respectively). Conclusion The chronic protocol enhanced the elastic stiffness of young tendon and the loads in both the young and old tendons. The old exposed tendons were found to exhibit higher load capacity than their younger counterparts, which differed from our initial hypothesis. PMID:19563638

  10. Regional stiffening with aging in tibialis anterior tendons of mice occurs independent of changes in collagen fibril morphology

    PubMed Central

    Wood, Lauren K.; Arruda, Ellen M.

    2011-01-01

    The incidence of tendon degeneration and rupture increases with advancing age. The mechanisms underlying this increased risk remain unknown but may arise because of age-related changes in tendon mechanical properties and structure. Our purpose was to determine the effect of aging on tendon mechanical properties and collagen fibril morphology. Regional mechanical properties and collagen fibril characteristics were determined along the length of tibialis anterior (TA) tendons from adult (8- to 12-mo-old) and old (28- to 30-mo-old) mice. Tangent modulus of all regions along the tendons increased in old age, but the increase was substantially greater in the proximal region adjacent to the muscle than in the rest of the tendon. Overall end-to-end modulus increased with old age at maximum tendon strain (799 ± 157 vs. 1,419 ± 91 MPa) and at physiologically relevant strain (377 ± 137 vs. 798 ± 104 MPa). Despite the dramatic changes in tendon mechanical properties from adulthood to old age, collagen fibril morphology and packing fraction remained relatively constant in all tendon regions examined. Since tendon properties are influenced by their external loading environment, we also examined the effect of aging on TA muscle contractile properties. Maximum isometric force did not differ between the age groups. We conclude that TA tendons stiffen in a region-dependent manner throughout the life span, but the changes in mechanical properties are not accompanied by corresponding changes in collagen fibril morphology or force-generating capacity of the TA muscle. PMID:21737825

  11. Os tibiale externum or sesamoid in the tendon of tibialis posterior.

    PubMed

    Bareither, D J; Muehleman, C M; Feldman, N J

    1995-01-01

    From a total of 165 foot and lower leg cadaveric specimens, 38 specimens were selected by palpation of the region of the tuberosity of the navicular for the possible presence of an accessory bone. Specimens were radiographed and dissected to reveal the presence of an accessory bone and its relationship to the tibialis posterior tendon. Nineteen of the specimens exhibited hypertrophy of the tibialis posterior tendon and 19 specimens exhibited an accessory bone. Specimens exhibiting an accessory bone were divided into two categories. In one group, the accessory bone was located in the tibialis posterior tendon prior to its division and was separated from the tuberosity by at least 3 mm. In the other group, the accessory bone was located in the main segment of the tibialis posterior tendon, connected to the tuberosity of the navicular by fibrous tissue, and, in some cases, exhibited a central cavity between the accessory bone and tuberosity. The accessory bone of specimens in the first group was considered to be a sesamoid in the tibialis posterior tendon and the accessory bone in the second group was an ossicle considered to be the os tibiale externum. Linking the os tibiale externum to the tibiale component of the primitive tetrapod foot rather than to the prehallux component eliminates the use of the term "prehallux" as an alternative name for this ossicle.

  12. [The operative treatment of the degenerative rupture of the anterior tibialis tendon].

    PubMed

    Schneppendahl, J; Gehrmann, S V; Stosberg, U; Regenbrecht, B; Windolf, J; Wild, M

    2010-05-01

    A degenerative tear of the anterior tibial tendon is a rare event compared to other tendons. The purpose of this study was to evaluate the functional results after surgical refixation. In a retrospective study, we report the functional outcome of five consecutive operatively treated patients suffering from a tear close to the insertion site of the anterior tibial tendon. All patients were assessed postoperatively, the AOFAS and Richter scores were obtained and the range of motion in the ankle joint was evaluated. Preoperatively all patients presented with a significant walking impairment due to a reduced active dorsiflexion, so the decision for surgical refixation was made. In all cases an MRI scan was performed preoperatively. Postoperative immobilisation without weight-bearing was done for six weeks. All patients returned to their former activity level, were satisfied with the postoperative result and had a normal gait in the follow-up examination. The range of motion was equal on both sides, the median AOFAS score was 86 and the median Richter score was 90 out of 100. There were no postoperative complications. Untreated tears of the anterior tibial tendon lead to significant impairment of the ankle joint and deformities of the foot. There is no consensus about the treatment with recommendations for operative and non-operative treatment. Various surgical procedures have been described. The surgical reconstruction of the tendon leads to a restored function of the ankle joint and allows a normal gait and is therefore desirable. Due to the loss of function and the good results after surgical treatment in our study, the non-operative treatment is not advisable. Surgical repair of degenerative tears of the anterior tibial tendon leads to very good functional results and high patient satisfaction.

  13. Acute effects of Achilles tendon vibration on soleus and tibialis anterior spinal and cortical excitability.

    PubMed

    Lapole, Thomas; Deroussen, François; Pérot, Chantal; Petitjean, Michel

    2012-08-01

    Prolonged vibration is known to alter muscle performance. Attenuation of Ia afferent efficacy is the main mechanism suggested. However, changes in motor cortex excitability could also be hypothesized. The purpose of the present study was therefore to analyze the acute and outlasting effects of 1 h of Achilles tendon vibration (frequency, 50 Hz) on the soleus (SOL) and tibialis anterior (TA) neuromuscular excitability. Spinal excitability was investigated by means of H-reflexes and F-waves while cortical excitability was characterized by motor evoked potentials (MEPs) obtained by transcranial magnetic stimulation. Twelve subjects performed the experimental procedures 3 times: at the beginning of the testing session (PRE), immediately after 1 h of Achilles tendon vibration (POST), and 1 h after the end of vibration (POST-1H). Prolonged vibration led to acute reduced H-reflex amplitudes for SOL only (46.9% ± 7.7% vs. 32.8% ± 7%; p = 0.006). Mainly presynaptic inhibition mechanisms were thought to be involved because of unchanged F-wave persistence and amplitude mean values, suggesting unaffected motoneuronal excitability. While no acute effects were reported for SOL and TA cortical excitability, both muscles were characterized by an outlasting increase in their MEP amplitude (0.64 ± 0.2 mV vs. 0.43 ± 0.18 mV and 2.17 ± 0.56 mV vs. 1.26 ± 0.36 mV, respectively; p < 0.05). The high modulation of Ia afferent input by vibration led to changes in motor cortex excitability that could contribute to the enhancement in muscular activation capacities reported after chronic use of tendon vibration.

  14. Foot segmental motion and coupling in stage II and III tibialis posterior tendon dysfunction.

    PubMed

    Van de Velde, Maarten; Matricali, Giovanni Arnoldo; Wuite, Sander; Roels, Charlotte; Staes, Filip; Deschamps, Kevin

    2017-06-01

    Classification systems developed in the field of posterior tibialis tendon dysfunction omit to include dynamic measurements. Since this may negatively affect the selection of the most appropriate treatment modality, studies on foot kinematics are highly recommended. Previous research characterised the foot kinematics in patients with posterior tibialis tendon dysfunction. However, none of the studies analysed foot segmental motion synchrony during stance phase, nor compared the kinematic behaviour of the foot in presence of different posterior tibialis tendon dysfunction stages. Therefore, we aimed at comparing foot segmental motion and coupling in patients with posterior tibialis tendon dysfunction grade 2 and 3 to those of asymptomatic subjects. Foot segmental motion of 11 patients suffering from posterior tibialis tendon dysfunction stage 2, 4 patients with posterior tibialis tendon dysfunction stage 3 and 15 asymptomatic subjects was objectively quantified with the Rizzoli foot model using an instrumented walkway and a 3D passive motion capture system. Dependent variables were the range of motion occurring at the different inter-segment angles during subphases of stance and swing phase as well as the cross-correlation coefficient between a number of segments. Significant differences in range of motion were predominantly found during the forefoot push off phase and swing phase. In general, both patient cohorts demonstrated a reduced range of motion compared to the control group. This hypomobility occurred predominantly in the rearfoot and midfoot (p<0.01). Significant differences between both posterior tibialis tendon dysfunction patient cohorts were not revealed. Cross-correlation coefficients highlighted a loss of joint coupling between rearfoot and tibia as well as between rearfoot and forefoot in both posterior tibialis tendon dysfunction groups. The current evidence reveals considerable mechanical alterations in the foot which should be considered in the

  15. Repair of Chronic Tibialis Anterior Tendon Rupture With a Major Defect Using Gracilis Allograft.

    PubMed

    Burton, Alex; Aydogan, Umur

    2016-08-01

    Tibialis anterior tendon (TAT) rupture is an uncommon injury, however, it can cause substantial deficit. Diagnosis is often delayed due to lack of initial symptoms; yet loss of function over time typically causes the patient to present for treatment. This delay usually ends up with major defects creating a great technical challenge for the operating surgeon. We present a novel technique and operative algorithm for the management of chronic TAT ruptures with a major gap after a delayed diagnosis not otherwise correctable with currently described techniques in the literature. This technique has been performed in 4 cases without any complications with fairly successful functional outcomes. For the reconstruction of chronic TAT rupture with an average delay of nine weeks after initial injury and gap of greater than 10 cm, a thorough operative algorithm was implemented in 4 patients using a double bundle gracilis allograft. Patients were then kept nonweightbearing for 6 weeks followed by weightbearing as tolerated. They began physical therapy with a focus on ankle exercises and gradual return to normal activity at 8 weeks, with resistance training exercises allowed at 12 weeks. At a mean follow-up time of 24.5 months, all patients reported significant pain relief with normal gait pattern. There were no reported intra- or postoperative complications. The average Foot and Ankle Ability Measure score increased to 90 from 27.5 in the postoperative period. All patients were able to return their previous activity levels. Gracilis allograft reconstruction as used in this study is a viable and reproducible alternative to primary repair with postoperative results being favorable without using complex tendon transfer techniques or autograft use necessitating the functional sacrifice of transferred or excised tendon. To the best of our knowledge, this is the first study demonstrating a successful technique and operative algorithm of gracilis allograft reconstruction of the TAT

  16. Intravital multiphoton imaging of mouse tibialis anterior muscle

    PubMed Central

    Lau, Jasmine; Goh, Chi Ching; Devi, Sapna; Keeble, Jo; See, Peter; Ginhoux, Florent; Ng, Lai Guan

    2016-01-01

    ABSTRACT Intravital imaging by multiphoton microscopy is a powerful tool to gain invaluable insight into tissue biology and function. Here, we provide a step-by-step tissue preparation protocol for imaging the mouse tibialis anterior skeletal muscle. Additionally, we include steps for jugular vein catheterization that allow for well-controlled intravenous reagent delivery. Preparation of the tibialis anterior muscle is minimally invasive, reducing the chances of inducing damage and inflammation prior to imaging. The tibialis anterior muscle is useful for imaging leukocyte interaction with vascular endothelium, and to understand muscle contraction biology. Importantly, this model can be easily adapted to study neuromuscular diseases and myopathies. PMID:28243520

  17. Interosseous membrane window size for tibialis posterior tendon transfer-Geometrical and MRI analysis.

    PubMed

    Wagner, Pablo; Ortiz, Cristian; Vela, Omar; Arias, Paul; Zanolli, Diego; Wagner, Emilio

    2016-09-01

    Tibialis posterior (TP) tendon transfer through the interosseous membrane is commonly performed in Charcot-Marie-Tooth disease. In order to avoid entrapment of this tendon, no clear recommendation relative to the interosseous membrane (IOM) incision size has been made. Analyze the TP size at the transfer level and therefore determine the most adequate IOM window size to avoid muscle entrapment. Eleven lower extremity magnetic resonances were analyzed. TP muscle measurements were made in axial views, obtaining the medial-lateral and antero-posterior diameter at various distances from the medial malleolus tip. The distance from the posterior to anterior compartment was also measured. These measurements were applied to a mathematical model to predict the IOM window size necessary to allow an ample TP passage in an oblique direction. The average tendon diameter (confidence-interval) at 15cm proximal to the medial malleolus tip was 19.47mm (17.47-21.48). The deep posterior compartment to anterior compartment distance was 10.97mm (9.03-12.90). Using a mathematical model, the estimated IOM window size ranges from 4.2 to 4.9cm. The IOM window size is of utmost importance in trans-membrane TP transfers, given that if equal or smaller than the transposed tendon oblique diameter, a high entrapment risk exists. A membrane window of 5cm or 2.5 times the size of the tendon diameter should be performed in order to theoretically diminish this complication. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  18. Ultrasound Imaging of Muscle Contraction of the Tibialis Anterior in Patients with Facioscapulohumeral Dystrophy.

    PubMed

    Gijsbertse, Kaj; Goselink, Rianne; Lassche, Saskia; Nillesen, Maartje; Sprengers, André; Verdonschot, Nico; van Alfen, Nens; de Korte, Chris

    2017-11-01

    A need exists for biomarkers to diagnose, quantify and longitudinally follow facioscapulohumeral muscular dystrophy (FSHD) and many other neuromuscular disorders. Furthermore, the pathophysiological mechanisms leading to muscle weakness in most neuromuscular disorders are not completely understood. Dynamic ultrasound imaging (B-mode image sequences) in combination with speckle tracking is an easy, applicable and patient-friendly imaging tool to visualize and quantify muscle deformation. This dynamic information provides insight in the pathophysiological mechanisms and may help to distinguish the various stages of diseased muscle in FSHD. In this proof-of-principle study, we applied a speckle tracking technique to 2-D ultrasound image sequences to quantify the deformation of the tibialis anterior muscle in patients with FSHD and in healthy controls. The resulting deformation patterns were compared with muscle ultrasound echo intensity analysis (a measure of fat infiltration and dystrophy) and clinical outcome measures. Of the four FSHD patients, two patients had severe peroneal weakness and two patients had mild peroneal weakness on clinical examination. We found a markedly varied muscle deformation pattern between these groups: patients with severe peroneal weakness showed a different motion pattern of the tibialis anterior, with overall less displacement of the central tendon region, while healthy patients showed a non-uniform displacement pattern, with the central aponeurosis showing the largest displacement. Hence, dynamic muscle ultrasound of the tibialis anterior muscle in patients with FSHD revealed a distinctively different tissue deformation pattern among persons with and without tibialis anterior weakness. These findings could clarify the understanding of the pathophysiology of muscle weakness in FSHD patients. In addition, the change in muscle deformation shows good correlation with clinical measures and quantitative muscle ultrasound measurements. In

  19. Intramuscular Electrical Stimulation for Muscle Activation of the Tibialis Anterior After Surgical Repair: A Case Report.

    PubMed

    Hollis, Sharon; McClure, Philip

    2017-12-01

    Background Loss of voluntary activation of musculature can result in muscle weakness. External neuromuscular stimulation can be utilized to improve voluntary activation but is often poorly tolerated because of pain associated with required stimulus level. Intramuscular electrical stimulation requires much lower voltage and may be better tolerated, and therefore more effective at restoring voluntary muscle activation. Case Description A 71-year-old man sustained a rupture of the distal attachment of the tibialis anterior tendon. Thirty-two weeks after surgical repair, there was no palpable or visible tension development in the muscle belly or tendon. Dorsiflexion was dependent on toe extensors. Electrical stimulation applied via a dry needling placement in the muscle belly was utilized to induce an isometric contraction. Outcomes Five sessions of intramuscular electrical stimulation were delivered. By day 4 (second visit), the patient was able to dorsiflex without prominent use of the extensor hallucis longus. By day 6 (third visit), active-range-of-motion dorsiflexion with toes flexed increased 20° (-10° to 10°). Eighteen days after the initial treatment, the patient walked without his previous high-step gait pattern, and the tibialis anterior muscle test improved to withstanding moderate resistance (manual muscle test score, 4/5). Discussion The rapid change in muscle function observed suggests that intramuscular electrical stimulation may facilitate voluntary muscle activation. Level of Evidence Therapy, level 5. J Orthop Sports Phys Ther 2017;47(12):965-969. Epub 15 Oct 2017. doi:10.2519/jospt.2017.7368.

  20. Intramuscular pressure varies with depth. The tibialis anterior muscle studied in 12 volunteers

    NASA Technical Reports Server (NTRS)

    Nakhostine, M.; Styf, J. R.; van Leuven, S.; Hargens, A. R.; Gershuni, D. H.

    1993-01-01

    Pressures in the tibialis anterior muscle were recorded at rest and during exercise with transducer-tipped catheters in 12 volunteers while they were supine or standing. The recordings were repeated with venous stasis created by an inflated tourniquet cuff on the thigh. Catheters were placed at 3 different sites in the muscle: catheter I adjacent to the deep surface of the fascia over the anterior compartment; catheter II between the fascia and the central tendon; and catheter III deep in the muscle close to the interosseous membrane. In both the supine and standing positions the intramuscular pressure at rest and the muscle relaxation pressure during exercise, obtained by catheter II, were greater than the corresponding pressures measured by the superficially located catheter I in the normal as well as in the volume loaded limb. The same conditions for pressure measurement consistently revealed lower pressures recorded by catheter III compared to II, but the difference was not significant. Our results indicate that intramuscular pressure increases centripetally, as the centrally lying tendon is approached. We conclude that pressure measurements for diagnosis of acute and chronic compartment syndromes and in ergonomic studies should be based on recordings from a standard location of the catheter within the muscle and a standard posture of the subject.

  1. A novel miniature in-line load-cell to measure in-situ tensile forces in the tibialis anterior tendon of rats.

    PubMed

    Schmoll, Martin; Unger, Ewald; Bijak, Manfred; Stoiber, Martin; Lanmüller, Hermann; Jarvis, Jonathan Charles

    2017-01-01

    Direct measurements of muscular forces usually require a substantial rearrangement of the biomechanical system. To circumvent this problem, various indirect techniques have been used in the past. We introduce a novel direct method, using a lightweight (~0.5 g) miniature (3 x 3 x 7 mm) in-line load-cell to measure tension in the tibialis anterior tendon of rats. A linear motor was used to produce force-profiles to assess linearity, step-response, hysteresis and frequency behavior under controlled conditions. Sensor responses to a series of rectangular force-pulses correlated linearly (R2 = 0.999) within the range of 0-20 N. The maximal relative error at full scale (20 N) was 0.07% of the average measured signal. The standard deviation of the mean response to repeated 20 N force pulses was ± 0.04% of the mean response. The step-response of the load-cell showed the behavior of a PD2T2-element in control-engineering terminology. The maximal hysteretic error was 5.4% of the full-scale signal. Sinusoidal signals were attenuated maximally (-4 dB) at 200 Hz, within a measured range of 0.01-200 Hz. When measuring muscular forces this should be of minor concern as the fusion-frequency of muscles is generally much lower. The newly developed load-cell measured tensile forces of up to 20 N, without inelastic deformation of the sensor. It qualifies for various applications in which it is of interest directly to measure forces within a particular tendon causing only minimal disturbance to the biomechanical system.

  2. Age-related motor unit remodeling in the Tibialis Anterior.

    PubMed

    Siddiqi, Ariba; Kumar, Dinesh; Arjunan, Sridhar

    2015-01-01

    Limited studies exist on the use of surface electromyogram (EMG) signal features to detect age-related motor unit remodeling in the Tibialis Anterior. Motor unit remodeling leads to declined muscle strength and force steadiness during submaximal contractions which are factors for risk of falls in the elderly. This study investigated the remodeling phenomena in the Tibialis Anterior using sample entropy and higher order statistics. Eighteen young (26.1 ± 2.9 years) and twelve elderly (68.7 ± 9.0 years) participants performed isometric dorsiflexion of the ankle at 20% maximal voluntary contraction (MVC) and their Tibialis Anterior (TA) EMG was recorded. Sample entropy, Gaussianity and Linearity Test statistics were calculated from the recorded EMG for each MVC. Shapiro-Wilk test was used to determine normality, and either a two-tail student t-test or Wilcoxon rank sum test was performed to determine significant difference in the EMG features between the young and old cohorts. Results show age-related motor unit remodeling to be depicted by decreased sample entropy (p <; 0.1), increased non-Gaussianity (p <; 0.05) and lesser degree of linearity in the elderly. This is due to the increased sparsity of the MUAPs as a result of the denervation-reinnervation process, and the decrease in total number of motor units.

  3. A novel miniature in-line load-cell to measure in-situ tensile forces in the tibialis anterior tendon of rats

    PubMed Central

    Unger, Ewald; Bijak, Manfred; Stoiber, Martin; Lanmüller, Hermann; Jarvis, Jonathan Charles

    2017-01-01

    Direct measurements of muscular forces usually require a substantial rearrangement of the biomechanical system. To circumvent this problem, various indirect techniques have been used in the past. We introduce a novel direct method, using a lightweight (~0.5 g) miniature (3 x 3 x 7 mm) in-line load-cell to measure tension in the tibialis anterior tendon of rats. A linear motor was used to produce force-profiles to assess linearity, step-response, hysteresis and frequency behavior under controlled conditions. Sensor responses to a series of rectangular force-pulses correlated linearly (R2 = 0.999) within the range of 0–20 N. The maximal relative error at full scale (20 N) was 0.07% of the average measured signal. The standard deviation of the mean response to repeated 20 N force pulses was ± 0.04% of the mean response. The step-response of the load-cell showed the behavior of a PD2T2-element in control-engineering terminology. The maximal hysteretic error was 5.4% of the full-scale signal. Sinusoidal signals were attenuated maximally (-4 dB) at 200 Hz, within a measured range of 0.01–200 Hz. When measuring muscular forces this should be of minor concern as the fusion-frequency of muscles is generally much lower. The newly developed load-cell measured tensile forces of up to 20 N, without inelastic deformation of the sensor. It qualifies for various applications in which it is of interest directly to measure forces within a particular tendon causing only minimal disturbance to the biomechanical system. PMID:28934327

  4. Tibialis anterior volumes and areas in ACL-injured limbs compared with unimpaired.

    PubMed

    Binder-Macleod, Benjamin I; Buchanan, Thomas S

    2006-09-01

    Past research has shown that subjects with ACL injuries show activation differences and atrophy in the muscles that cross the knee, including the gastrocnemii, which predominately act at the ankle. However, it is not known how the other ankle muscles that do not cross the knee are affected. We focused on the two muscles that control the ankle, the soleus and tibialis anterior muscles, to see how they were affected by an ACL injury. We hypothesized that the ankle muscles of subjects with ACL injuries that did not require surgery (copers) would be more like normals and that the muscles of subjects with ACL injuries who required surgery to return to normal activity (noncopers) would atrophy. Twenty-seven subjects were divided into three even categories: unimpaired subjects, copers, and noncopers. Axial spin-echo T1-weighted MRI images were used to digitally reconstruct the tibialis anterior and the soleus. We used the digitally reconstructed muscles to determine the peak cross-sectional area and volume of each muscle. The copers' tibialis anterior muscles were similar to the unimpaired subjects, but, surprisingly, the noncoper's tibialis anterior muscles of the injured leg were larger than those of their uninjured legs (P < 0.05). In the soleus, the results showed a trend of not being affected. The increase in size of the tibialis anterior in noncopers may have been caused by altered gait patterns in noncopers. We believe this is due to either an ankle-stiffening strategy during heel strike or from the inversion of the foot causing external rotation of the tibia as a stabilizing technique for the knee.

  5. Acute Tears of the Tibialis Posterior Tendon Following Ankle Sprain.

    PubMed

    Jackson, Lyle T; Dunaway, Linda J; Lundeen, Gregory A

    2017-07-01

    Traumatic tears of the tibialis posterior (TP) tendon following an ankle sprain are rare. The purpose of this study was to report our case series of TP tendon tears following an ankle sprain. Patients with persistent TP tendon pain after an ankle sprain were retrospectively identified over a 4-year period and reviewed. A comparison of magnetic resonance imaging (MRI) interpretations by a radiologist and surgeon was made. Patients failing conservative management underwent operative repair of the TP tendon tear and concomitant pathology. Failure of the index surgery was defined as TP tendinosis, which was treated with excision and flexor digitorum longus tendon transfer. Outcomes were measured with the Foot Function Index (FFI) and American Orthopaedic Foot & Ankle Society (AOFAS) hindfoot scores. Thirteen patients were found to have a TP tendon tear following an ankle sprain. The incidence for TP tears with sprains presented to our clinic was 1.04%. MRI identified TP tendon pathology in 4 patients by a radiologist review and in 11 patients by a surgeon review. The most common concomitant pathology was a talar osteochondral defect in 13 of 13 patients and ligament instability in 12 of 13 patients (5/13 lateral, 3/13 medial, 4/13 multidirectional instability). Four of 13 patients failed the index surgery. Of the 9 remaining patients, 4 had clinical follow-up at an average of 4.6 years postoperatively. The average FFI subscale scores were the following: pain, 40.4; disability, 28.9; and activity, 23.6. The average AOFAS hindfoot score was 68.8. Despite being rare, a TP tendon tear should be included in the differential diagnosis for persistent medial-sided pain following an ankle sprain. MRI findings can be subtle. Associated pathology was very common and likely confounded the diagnosis and outcomes. Patients should be counseled on the possibility of poor outcomes and long-term pain. Level IV, case series.

  6. Non-operative management of posterior tibialis tendon dysfunction: design of a randomized clinical trial [NCT00279630

    PubMed Central

    Kulig, Kornelia; Pomrantz, Amy B; Burnfield, Judith M; Reischl, Stephen F; Mais-Requejo, Susan; Thordarson, David B; Smith, Ronald W

    2006-01-01

    Background Posterior tibialis tendon dysfunction (PTTD) is a common cause of foot pain and dysfunction in adults. Clinical observations strongly suggest that the condition is progressive. There are currently no controlled studies evaluating the effectiveness of exercise, orthoses, or orthoses and exercise on Stage I or IIA PTTD. Our study will explore the effectiveness of an eccentric versus concentric strengthening intervention to results obtained with the use of orthoses alone. Findings from this study will guide the development of more efficacious PTTD intervention programs and contribute to enhanced function and quality of life in persons with posterior tibialis tendon dysfunction. Methods/design This paper presents the rationale and design for a randomized clinical trial evaluating the effectiveness of a treatment regime for the non-operative management of Stage I or IIA PTTD. Discussion We have presented the rationale and design for an RCT evaluating the effectiveness of a treatment regimen for the non-operative management of Stage I or IIA PTTD. The results of this trial will be presented as soon as they are available. PMID:16756656

  7. Action of vanillin (Vanilla planifolia) on the morphology of tibialis anterior and soleus muscles after nerve injury

    PubMed Central

    Peretti, Ana Luiza; Antunes, Juliana Sobral; Lovison, Keli; Kunz, Regina Inês; Castor, Lidyane Regina Gomes; Brancalhão, Rose Meire Costa; Bertolini, Gladson Ricardo Flor; Ribeiro, Lucinéia de Fátima Chasko

    2017-01-01

    ABSTRACT Objective To evaluate the action of vanillin (Vanilla planifolia) on the morphology of tibialis anterior and soleus muscles after peripheral nerve injury. Methods Wistar rats were divided into four groups, with seven animals each: Control Group, Vanillin Group, Injury Group, and Injury + Vanillin Group. The Injury Group and the Injury + Vanillin Group animals were submitted to nerve injury by compression of the sciatic nerve; the Vanillin Group and Injury + Vanillin Group, were treated daily with oral doses of vanillin (150mg/kg) from the 3rd to the 21st day after induction of nerve injury. At the end of the experiment, the tibialis anterior and soleus muscles were dissected and processed for light microscopy and submitted to morphological analysis. Results The nerve compression promoted morphological changes, typical of denervation, and the treatment with vanillin was responsible for different responses in the studied muscles. For the tibialis anterior, there was an increase in the number of satellite cells, central nuclei and fiber atrophy, as well as fascicular disorganization. In the soleus, only increased vascularization was observed, with no exacerbation of the morphological alterations in the fibers. Conclusion The treatment with vanillin promoted increase in intramuscular vascularization for the muscles studied, with pro-inflammatory potential for tibialis anterior, but not for soleus muscle. PMID:28767917

  8. Relative changes with contraction in the central excitability state of the tibialis anterior and calf muscles.

    PubMed Central

    Fisher, M A

    1980-01-01

    F responses were recorded from the surface of the tibialis muscle and medial aspect of the soleus muscle in 14 normal subjects. The persistence (that is the fraction of measurable F responses found with a series of supramaximal stimuli) and average F amplitudes (measured peak-to-peak and based on at least five F responses) were determined both at rest and with isometric contraction with the ankle maintained at 90 degrees. Although the persistence at rest was significantly less in the tibialis anterior soleus than the (p less than 0.001), no significant difference was found with the muscles contracted. This was associated with a significant increase in both average F amplitudes and average F amplitude/direct motor response ratios in the tibialis anterior in comparison to the soleus. In four of the subjects, studies were also performed when the H reflex in the soleus muscle was eliminated by thigh compression. Comparable changes in both F response persistence and average F amplitude were found with and without an H reflex. These data indicate that, in contrast to the situation at rest, with isometric contraction the "central excitatory state" of the tibialis anterior is at least as great as in its antagonist antigravity muscles and that this is not due simply to increased large fiber reflex input associated with agonist contraction. PMID:7373321

  9. Plyometric Training Favors Optimizing Muscle–Tendon Behavior during Depth Jumping

    PubMed Central

    Hirayama, Kuniaki; Iwanuma, Soichiro; Ikeda, Naoki; Yoshikawa, Ayumi; Ema, Ryoichi; Kawakami, Yasuo

    2017-01-01

    The purpose of the present study was to elucidate how plyometric training improves stretch–shortening cycle (SSC) exercise performance in terms of muscle strength, tendon stiffness, and muscle–tendon behavior during SSC exercise. Eleven men were assigned to a training group and ten to a control group. Subjects in the training group performed depth jumps (DJ) using only the ankle joint for 12 weeks. Before and after the period, we observed reaction forces at foot, muscle–tendon behavior of the gastrocnemius, and electromyographic activities of the triceps surae and tibialis anterior during DJ. Maximal static plantar flexion strength and Achilles tendon stiffness were also determined. In the training group, maximal strength remained unchanged while tendon stiffness increased. The force impulse of DJ increased, with a shorter contact time and larger reaction force over the latter half of braking and initial half of propulsion phases. In the latter half of braking phase, the average electromyographic activity (mEMG) increased in the triceps surae and decreased in tibialis anterior, while fascicle behavior of the gastrocnemius remained unchanged. In the initial half of propulsion, mEMG of triceps surae and shortening velocity of gastrocnemius fascicle decreased, while shortening velocity of the tendon increased. These results suggest that the following mechanisms play an important role in improving SSC exercise performance through plyometric training: (1) optimization of muscle–tendon behavior of the agonists, associated with alteration in the neuromuscular activity during SSC exercise and increase in tendon stiffness and (2) decrease in the neuromuscular activity of antagonists during a counter movement. PMID:28179885

  10. Hamstring tendon versus patellar tendon anterior cruciate ligament reconstruction using biodegradable interference fit fixation: a prospective matched-group analysis.

    PubMed

    Wagner, Michael; Kääb, Max J; Schallock, Jessica; Haas, Norbert P; Weiler, Andreas

    2005-09-01

    There are still controversies about graft selection for primary anterior cruciate ligament reconstruction, especially with respect to knee stability and functional outcome. Biodegradable interference screw fixation of hamstring tendon grafts provides clinical results similar to those achieved with identical fixation of bone-patellar tendon-bone grafts. Cohort study; Level of evidence, 2. In 1996 and 1997, primary isolated anterior cruciate ligament reconstruction using a bone-patellar tendon-bone autograft was performed in 72 patients. Since 1998, hamstring tendons were used as routine grafts. Matched patients with a hamstring tendon graft were selected from a database (n = 284). All patients were followed prospectively for a minimum of 2 years with KT-1000 arthrometer testing, International Knee Documentation Committee score, and Lysholm score. In the bone-patellar tendon-bone group, 9 patients were excluded because of bilateral rupture of the anterior cruciate ligament, 3 patients (4.2%) had a graft rupture, and 4 patients were lost to follow-up (follow-up rate, 92.1%), leaving 56 patients for a matched-group analysis. In the hamstring tendon database, the graft rupture rate was 5.6% (P = .698). The Lysholm score was 89.7 in the patellar tendon group and 94 in the hamstring tendon group (P = .003). The KT-1000 arthrometer side-to-side difference was 2.6 mm for the patellar tendon group and 2.1 mm for the hamstring tendon group (P = .041). There were significantly less positive pivot-shift test results in the hamstring tendon group (P = .005), and hamstring tendon patients showed lower thigh atrophy (P = .024) and patellofemoral crepitus (P = .003). Overall International Knee Documentation Committee scores were better (P = .001) in the hamstring tendon group (hamstring tendon: 34 x A, 21 x B, 0 x C, 0 x D; bone-patellar tendon-bone: 17 x A, 32 x B, 6 x C, 0 x D). In this comparison of anterior cruciate ligament reconstruction with bone-patellar tendon-bone and

  11. Revision of anterior cruciate ligament reconstruction with allografts in patients younger than 40 years old: a 2 to 4 year results.

    PubMed

    Pascual-Garrido, Cecilia; Carbo, L; Makino, A

    2014-05-01

    The purpose of this study is first to report the outcomes, at 4 years follow-up, in revision ACL surgery using allografts in patients younger than 40 years old, and then compared soft tissue allografts to bone tendon allografts. This retrospective study included 47 patients who underwent ACL revision surgery with fresh-frozen allografts. Patellar tendon allograft or tibialis anterior allograft was used. Twenty-seven patients undergoing ACL revision with patellar tendon allograft were compared retrospectively with twenty-two patients undergoing the same procedure with soft tissue tibialis anterior allograft. Lysholm, IKDC, and KT-1000 values were obtained preoperatively and postoperatively. The average patient follow-up was 4.6 years (±2.5). The mean age at time of the revision was 34 years old (±6.3). Overall, patients reported the overall condition of their knee as excellent or good in 85% of the patients (10 excellent, 33 good). Based on their experience, 85% would have the surgery again if they had the same problem in the other knee. Both subgroups experienced significant improvement in Lysholm, IKDC, and KT-1000 values, with no difference found between groups at final follow-up. Revision ACL with allografts has excellent and good results in 85% of patients younger than 40 years old. No statistical difference was seen between soft tissue (tibialis anterior) and patellar tendon allograft. IV.

  12. Changes in tibialis anterior corticospinal properties after acute prolonged muscle vibration.

    PubMed

    Farabet, Adrien; Souron, Robin; Millet, Guillaume Y; Lapole, Thomas

    2016-06-01

    Prolonged local vibration is known to impair muscle performance. While involved mechanisms were previously evidenced at the spinal level, changes at the cortical level were also hypothesized. The aims of the present study were to investigate the effects of 30 min of 100-Hz tibialis anterior muscle vibration on force production capacities and to further identify the respective changes in spinal loop properties, descending voluntary drive and corticospinal properties. Thirteen subjects were tested before and after a vibration condition, and before and after a resting control condition. Maximal voluntary contraction (MVC) in dorsiflexion was measured. Transcranial magnetic stimulation was superimposed during MVCs to assess cortical voluntary activation (VATMS), motor-evoked potential amplitude (MEP) and cortical silent period length (CSP). MEP and CSP were also measured during 50 and 75 % MVC contractions. Spinal excitability was investigated by mean of H-reflex. There were no vibration effects on MVC (p = 0.805), maximal EMG activity (p = 0.653), VATMS (p = 1), and CSP (p = 0.877). Vibration tended to decrease MEP amplitude (p = 0.117). H-reflex amplitude was depressed following vibration (p = 0.008). Dorsiflexion maximal force production capacities were unaffected by 30 min of tibialis anterior muscle vibration, despite spinal loop and corticospinal excitabilities being reduced. These findings suggest that acute prolonged vibration has the potential to modulate corticospinal excitability of lower limb muscles without a concomitant functional consequence.

  13. Complex Anatomic Abnormalities of the Lower Leg Muscles and Tendons Associated With Phocomelia: A Case Report.

    PubMed

    Hodo, Thomas; Hamrick, Mark; Melenevsky, Yulia

    Musculoskeletal anatomy is widely known to have components that stray from the norm in the form of variant muscle and tendon presence, absence, origin, insertion, and bifurcation. Although these variant muscles and tendons might be deemed incidental and insignificant findings by most, they can be important contributors to pathologic physiology or, more importantly, an option for effective treatment. In the present case report, we describe a patient with phocomelia and Müllerian abnormalities secondary to in utero thalidomide exposure. The patient had experienced recurrent bilateral foot pain accompanied by numbness, stiffness, swelling, and longstanding pes planus. These symptoms persisted despite conservative treatment with orthotics, steroids, and nonsteroidal anti-inflammatory drugs. Radiographic imaging showed dysmorphic and degenerative changes of the ankle and foot joints. Further investigation with magnetic resonance imaging revealed complex anatomic abnormalities, including the absence of the posterior tibialis and peroneus brevis, lateralization of the peroneus longus, and the presence of a variant anterior compartment muscle. The variant structure was likely a previously described anterior compartment variant, anterior fibulocalcaneus, and might have been a source of the recurrent pain. Also, the absence of the posterior tibialis might have caused the pes planus in the present patient, considering that posterior tibialis tendon dysfunction is the most common cause of acquired pes planus. Although thalidomide infrequently affects the lower extremities, its effects on growth and development were likely the cause of this rare array of anatomic abnormalities and resulting ankle and foot pathologic features. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Non-linear finite element model to assess the effect of tendon forces on the foot-ankle complex.

    PubMed

    Morales-Orcajo, Enrique; Souza, Thales R; Bayod, Javier; Barbosa de Las Casas, Estevam

    2017-11-01

    A three-dimensional foot finite element model with actual geometry and non-linear behavior of tendons is presented. The model is intended for analysis of the lower limb tendon forces effect in the inner foot structure. The geometry of the model was obtained from computational tomographies and magnetic resonance images. Tendon tissue was characterized with the first order Ogden material model based on experimental data from human foot tendons. Kinetic data was employed to set the load conditions. After model validation, a force sensitivity study of the five major foot extrinsic tendons was conducted to evaluate the function of each tendon. A synergic work of the inversion-eversion tendons was predicted. Pulling from a peroneus or tibialis tendon stressed the antagonist tendons while reducing the stress in the agonist. Similar paired action was predicted for the Achilles tendon with the tibialis anterior. This behavior explains the complex control motion performed by the foot. Furthermore, the stress state at the plantar fascia, the talocrural joint cartilage, the plantar soft tissue and the tendons were estimated in the early and late midstance phase of walking. These estimations will help in the understanding of the functional role of the extrinsic muscle-tendon-units in foot pronation-supination. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Measuring Regional Changes in Damaged Tendon

    NASA Astrophysics Data System (ADS)

    Frisch, Catherine Kayt Vincent

    Mechanical properties of tendon predict tendon health and function, but measuring these properties in vivo is difficult. An ultrasound-based (US) analysis technique called acoustoelastography (AE) uses load-dependent changes in the reflected US signal to estimate tissue stiffness non-invasively. This thesis explores whether AE can provide information about stiffness alteration resulting from tendon tears both ex vivo and in vivo. An ex vivo ovine infraspinatus tendon model suggests that the relative load transmitted by the different tendon layers transmit different fractions of the load and that ultrasound echo intensity change during cyclic loading decreases, becoming less consistent once the tendon is torn. An in vivo human tibialis anterior tendon model using electrically stimulated twitch contractions investigated the feasibility of measuring the effect in vivo. Four of the five subjects showed the expected change and that the muscle contraction times calculated using the average grayscale echo intensity change compared favorably with the times calculated based on the force data. Finally an AE pilot study with patients who had rotator cuff tendon tears found that controlling the applied load and the US view of the system will be crucial to a successful in vivo study.

  16. Function-sparing tibialis anterior pivoted muscle flap for reconstruction of post-burn and post-traumatic middle-third leg defects with exposed tibia

    PubMed Central

    Megahed, M.A.

    2011-01-01

    Summary Reconstruction of the middle third of the leg is a challenging procedure. The tibialis anterior muscle flap can be useful in reconstruction of the middle third of the leg with exposed tibia. The aim of this work was to evaluate the efficacy of tibialis anterior pivoted muscle flap for reconstruction of the middle third of the leg with functional preservation. This study, performed in the Plastic, Reconstructive and Burn Unit, Menoufiya University Hospital, Egypt, included 16 patients (13 males and 3 females) during the period February 2007/May 2010: seven post-burn and nine post-traumatic patients with post-burn middle-third leg defects with exposed tibia. Their ages ranged from 14 to 67 years. A function-sparing lateral split tibialis anterior pivoted muscle flap was used in all the patients. Follow-up ranged from six months to two years. Partial flap loss occurred in one patient (6.25%), there was no post-operative haematoma or infection, and only one case of wound dehiscence (6.25%), managed by secondary suture. No donor site morbidity or any significant functional impairment was observed, and the subjective aesthetic results were satisfactory. Lateral split tibialis anterior pivoted muscle flap is a useful, simple technique, allowing rapid, durable and reliable coverage of middle-third leg defects without significant impairment of function and without sacrificing major nerves or vessels in the foot, and without any donor site morbidity. PMID:22262962

  17. [Anterior dislocation of the popliteus tendon].

    PubMed

    Martinez Molina, Oscar

    2009-01-01

    Review the most relevant aspects of the posterolateral corner anatomy of the knee, based on the analysis of papers that throughout the years have made important contributions to the knowledge of these structures. Last et al rejected the idea that the popliteal tendon is an isolated structure, suggesting rather that its variants are closely linked to other anatomical structures. The studies by Tria et al contributed the features of the tendon as it attaches to the lateral condyle, just to mention a couple of examples. This is the case of a 48 year-old female patient with a knee injury caused by an external rotation mechanism. Clinical features included pain, a protruding sensation in the lateral aspect of the knee, and voluntary pseudoblocking resulting from external rotation maneuvers. Knee arthroscopy was performed and dislocation of the popliteal tendon anterior to the lateral condyle was diagnosed, besides a longitudinal tear. The tendon was repositioned, radiofrequency was applied to both the tendon and the popliteal hiatus, and the former was kept in place with a plaster cast worn for 6 weeks. Even though the isolated tear or avulsion of the tendon has already been reported, the dislocation or instability of the popliteal tendon as it relates to the lateral femoral condyle has apparently not been approached yet. As we did in this case, other authors have also confirmed the diagnosis arthroscopically, Naver in 1985, Rose in 1988, and Burstein in 1990.

  18. Conservative treatment of tibialis posterior tendon dysfunction--a review.

    PubMed

    Bowring, Beverly; Chockalingam, Nachiappan

    2010-03-01

    Appropriate conservative treatment is considered essential to address symptoms associated with tibialis posterior tendon dysfunction (TPTD) and prevent its potential long-term disabling consequences. The main aim of this review, undertaken in 2007, was to evaluate the evidence from studies for the effects of conservative treatment modalities in the management of TPTD. This evidence could then be used as a basis for the development of a clinical guideline for the management of the condition. Studies were selected according to specific criteria and evaluated for methodological quality. As preliminary literature searches had identified no randomised controlled trials at the time of the review, studies of lower hierarchy were included. Five uncontrolled observational studies evaluating the outcomes of various orthotic treatments alone or in combination with other therapies were included in the review. Different study designs, methodological quality, population characteristics, interventions and outcome measures were found. Limited and poor quality evidence was found in this review regarding the conservative treatment of TPTD. Thus a cause-effect relationship between intervention and outcome could not be established nor an optimal conservative treatment regime for the condition. Further better quality research is warranted in this area to inform practice, particularly as there is no consensus in the literature regarding treatment of this condition. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  19. Achilles tendon vibration-induced changes in plantar flexor corticospinal excitability.

    PubMed

    Lapole, Thomas; Temesi, John; Gimenez, Philippe; Arnal, Pierrick J; Millet, Guillaume Y; Petitjean, Michel

    2015-02-01

    Daily Achilles tendon vibration has been shown to increase muscle force, likely via corticospinal neural adaptations. The aim of the present study was to determine the extent by which corticospinal excitability is influenced during direct Achilles tendon vibration. Motor-evoked potentials (MEPs) were elicited in the soleus (SOL), gastrocnemius medialis (GM) and tibialis anterior (TA) by transcranial magnetic stimulation of the motor cortical area of the leg with and without Achilles tendon vibration at various frequencies (50, 80 and 110 Hz). Contralateral homologues were also investigated. SOL and GM MEP amplitude significantly increased by 226 ± 188 and 66 ± 39%, respectively, during Achilles tendon vibration, without any difference between the tested frequencies. No MEP changes were reported for TA or contralateral homologues. Increased SOL and GM MEP amplitude suggests increased vibration-induced corticospinal excitability independent of vibration frequency.

  20. Doppler ultrasonography of the anterior knee tendons in elite badminton players: colour fraction before and after match.

    PubMed

    Koenig, M J; Torp-Pedersen, S; Boesen, M I; Holm, C C; Bliddal, H

    2010-02-01

    Anterior knee tendon problems are seldom reported in badminton players although the game is obviously stressful to the lower extremities. Painful anterior knee tendons are common among elite badminton players. The anterior knee tendons exhibit colour Doppler activity. This activity increases after a match. Painful tendons have more Doppler activity than tendons without pain. Cohort study. 72 elite badminton players were interviewed about training, pain and injuries. The participants were scanned with high-end ultrasound equipment. Colour Doppler was used to examine the tendons of 64 players before a match and 46 players after a match. Intratendinous colour Doppler flow was measured as colour fraction (CF). The tendon complex was divided into three loci: the quadriceps tendon, the proximal patellar tendon and the insertion on the tibial tuberosity. Interview: Of the 72 players, 62 players had problems with 86 tendons in the lower extremity. Of these 86 tendons, 48 were the anterior knee tendons. Ultrasound: At baseline, the majority of players (87%) had colour Doppler flow in at least one scanning position. After a match, the percentage of the knee complexes involved did not change. CF increased significantly in the dominant leg at the tibial tuberosity; single players had a significantly higher CF after a match at the tibial tuberosity and in the patellar tendon both before and after a match. Painful tendons had the highest colour Doppler activity. Most elite badminton players had pain in the anterior knee tendons and intratendinous Doppler activity both before and after match. High levels of Doppler activity were associated with self-reported ongoing pain.

  1. Action of vanillin (Vanilla planifolia) on the morphology of tibialis anterior and soleus muscles after nerve injury.

    PubMed

    Peretti, Ana Luiza; Antunes, Juliana Sobral; Lovison, Keli; Kunz, Regina Inês; Castor, Lidyane Regina Gomes; Brancalhão, Rose Meire Costa; Bertolini, Gladson Ricardo Flor; Ribeiro, Lucinéia de Fátima Chasko

    2017-01-01

    To evaluate the action of vanillin (Vanilla planifolia) on the morphology of tibialis anterior and soleus muscles after peripheral nerve injury. Wistar rats were divided into four groups, with seven animals each: Control Group, Vanillin Group, Injury Group, and Injury + Vanillin Group. The Injury Group and the Injury + Vanillin Group animals were submitted to nerve injury by compression of the sciatic nerve; the Vanillin Group and Injury + Vanillin Group, were treated daily with oral doses of vanillin (150mg/kg) from the 3rd to the 21st day after induction of nerve injury. At the end of the experiment, the tibialis anterior and soleus muscles were dissected and processed for light microscopy and submitted to morphological analysis. The nerve compression promoted morphological changes, typical of denervation, and the treatment with vanillin was responsible for different responses in the studied muscles. For the tibialis anterior, there was an increase in the number of satellite cells, central nuclei and fiber atrophy, as well as fascicular disorganization. In the soleus, only increased vascularization was observed, with no exacerbation of the morphological alterations in the fibers. The treatment with vanillin promoted increase in intramuscular vascularization for the muscles studied, with pro-inflammatory potential for tibialis anterior, but not for soleus muscle. Avaliar a ação da vanilina (Vanilla planifolia) sobre a morfologia dos músculos tibial anterior e sóleo após lesão nervosa periférica. Ratos Wistar foram divididos em quatro grupos, com sete animais cada, sendo Grupo Controle, Grupo Vanilina, Grupo Lesão e Grupo Lesão + Vanilina. Os animais dos Grupos Lesão e Grupo Lesão + Vanilina foram submetidos à lesão nervosa por meio da compressão do nervo isquiático, e os Grupos Vanilina e Grupo Lesão + Vanilina foram tratados diariamente com doses orais de vanilina (150mg/kg) do 3o ao 21o dia após a indução da lesão nervosa. Ao término do

  2. How does a cadaver model work for testing ultrasound diagnostic capability for rheumatic-like tendon damage?

    PubMed

    Janta, Iustina; Morán, Julio; Naredo, Esperanza; Nieto, Juan Carlos; Uson, Jacqueline; Möller, Ingrid; Bong, David; Bruyn, George A W; D Agostino, Maria Antonietta; Filippucci, Emilio; Hammer, Hilde Berner; Iagnocco, Annamaria; Terslev, Lene; González, Jorge Murillo; Mérida, José Ramón; Carreño, Luis

    2016-06-01

    To establish whether a cadaver model can serve as an effective surrogate for the detection of tendon damage characteristic of rheumatoid arthritis (RA). In addition, we evaluated intraobserver and interobserver agreement in the grading of RA-like tendon tears shown by US, as well as the concordance between the US findings and the surgically induced lesions in the cadaver model. RA-like tendon damage was surgically induced in the tibialis anterior tendon (TAT) and tibialis posterior tendon (TPT) of ten ankle/foot fresh-frozen cadaveric specimens. Of the 20 tendons examined, six were randomly assigned a surgically induced partial tear; six a complete tear; and eight left undamaged. Three rheumatologists, experts in musculoskeletal US, assessed from 1 to 5 the quality of US imaging of the cadaveric models on a Likert scale. Tendons were then categorized as having either no damage, (0); partial tear, (1); or complete tear (2). All 20 tendons were blindly and independently evaluated twice, over two rounds, by each of the three observers. Overall, technical performance was satisfactory for all items in the two rounds (all values over 2.9 in a Likert scale 1-5). Intraobserver and interobserver agreement for US grading of tendon damage was good (mean κ values 0.62 and 0.71, respectively), with greater reliability found in the TAT than the TPT. Concordance between US findings and experimental tendon lesions was acceptable (70-100 %), again greater for the TAT than for the TPT. A cadaver model with surgically created tendon damage can be useful in evaluating US metric properties of RA tendon lesions.

  3. High Prevalence of Obesity and Female Gender Among Patients With Concomitant Tibialis Posterior Tendonitis and Plantar Fasciitis.

    PubMed

    Reb, Christopher W; Schick, Faith A; Karanjia, Homyar N; Daniel, Joseph N

    2015-10-01

    The link between increased body weight and hindfoot complaints is largely based on correlation to single foot pathology. We retrospectively reviewed 6879 patients with tibialis posterior tendonitis (TPT), plantar fasciitis (PF), or both. Among patients with either TPT or PF, 1 in 11 (9%) had both. We then compared age, gender, and body mass index among these groups. Patients with both diagnoses were neither statistically older nor more obese than patients with single diagnoses. However, they were statistically more female. Given the overall high prevalence of obesity in the study population, we feel these data support the link between obesity and multiple foot pathology. Prognostic, Level IV: Case series. © 2015 The Author(s).

  4. Dynamic effect of the tibialis posterior muscle on the arch of the foot during cyclic axial loading.

    PubMed

    Kamiya, Tomoaki; Uchiyama, Eiichi; Watanabe, Kota; Suzuki, Daisuke; Fujimiya, Mineko; Yamashita, Toshihiko

    2012-11-01

    The most common cause of acquired flatfoot deformity is tibialis posterior tendon dysfunction. The present study compared the change in medial longitudinal arch height during cyclic axial loading with and without activated tibialis posterior tendon force. Fourteen normal, fresh frozen cadaveric legs were used. A total of 10,000 cyclic axial loadings of 500 N were applied to the longitudinal axis of the tibia. The 32-N tibialis posterior tendon forces were applied to the specimens of the active group (n=7). Specimens of another group (non-active group, n=7) were investigated without the tibialis posterior tendon force. The bony arch index was calculated from the displacement of the navicular height. The mean initial bony arch indexes with maximal weightbearing were 0.239 (SD 0.009) in active group and 0.239 (SD 0.014) in non-active group. After 7000 cycles, the bony arch indexes with maximal weightbearing were significantly greater in the active group (mean 0.214, SD 0.013) than in the non-active group (mean 0.199, SD 0.013). The mean bony arch indexes with maximal weightbearing after 10,000 cycles were 0.212 (SD 0.011) in the active group and 0.196 (SD 0.015) in the non-active group. The passive supportive structures were inadequate, and the tibialis posterior muscle was essential to maintain the medial longitudinal arch of the foot in the dynamic weightbearing condition. The findings underscore that physical therapy and arch supportive equipments are important to prevent flatfoot deformity in the condition of weakness or dysfunction of the tibialis posterior muscle. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. The influence of freezing on the tensile strength of tendon grafts : a biomechanical study.

    PubMed

    Arnout, Nele; Myncke, Jan; Vanlauwe, Johan; Labey, Luc; Lismont, Daniel; Bellemans, Johan

    2013-08-01

    We investigated the influence of freezing on the tensile strength of fresh frozen tendon grafts. The biomechanical characteristics of tendons that are less commonly used in knee surgery (tibialis anterior, tibialis posterior, peroneus longus and medial and lateral half of Achilles tendons) were compared to those of a semitendinosus and gracilis graft harvested from the same 10 multi-organ donors. All right side tendons constituted the study group and were frozen at -80 degrees C and thawed at room temperature 5 times. All left side tendons were frozen at -80 degrees C and thawed at room temperature once. There were 59 tendons in the control group and 56 in the study group. The looped grafts were clamped at one side using a custom-made freeze clamp and loaded until failure on an Instron 4505 testing machine. The average ultimate failure load was not significantly different between the control and the study group (p > 0.05). The failure load of the medial tendon Achilles was the lowest in both study and control group (p < 0.001). There was no significant difference in maximum stress, maximum displacement, maximum strain and stiffness between the control and study group (p > 0.05). From our study, we conclude that freezing tendons at -80 degrees C and thawing several times does not influence the maximum load, maximum stress, maximum displacement, maximum strain and stiffness. The medial half of the Achilles tendon is clearly the weakest tendon (p < 0.001). These findings show that tendon grafts can be frozen at -80 degrees C and thawed at room temperature several times without altering their biomechanical properties.

  6. Rupture of the anterior tibial tendon: three clinical cases, anatomical study, and literature review.

    PubMed

    Anagnostakos, Konstantinos; Bachelier, Felix; Fürst, Oliver Alexander; Kelm, Jens

    2006-05-01

    We report three cases of anterior tibial tendon ruptures and the results of an anatomical study in regard to the tendon's insertion site and a literature review. Three patients were referred to our hospital with anterior tibial tendon ruptures. In the anatomical study, 53 feet were dissected, looking in particular for variants of the bony insertion of the tendon. Two patients had surgical treatment (one primary repair and one semimembranosus tendon graft) and one conservative treatment. After a mean followup of 14 weeks all patients had satisfactory outcomes. In the anatomical study, we noted three different insertion sites: in 36 feet the tendon inserted into the medial side of the cuneiform and the base of the first metatarsal bone and in 13 feet only into the medial side of the cuneiform bone. In the remaining four feet the tendon inserted into the cuneiform and the first metatarsal bone, but an additional tendon was noted taking its origin from the anterior tibial tendon near its insertion into the medial cuneiform and attaching to the proximal part of the first metatarsal. According to literature, surgical repair is the treatment of choice for acute ruptures and for patients with high activity levels. For chronic ruptures and patients with low demands, conservative management may lead to an equally good outcome. Knowledge of the anatomy in this region may be helpful for diagnosis and for the interpretation of intraoperative findings and choosing the most appropriate surgical procedure.

  7. Free Bone Plug Quadriceps Tendon Harvest and Suspensory Button Attachment for Anterior Cruciate Ligament Reconstruction.

    PubMed

    Todor, Adrian; Caterev, Sergiu; Nistor, Dan Viorel; Khallouki, Youssef

    2016-06-01

    The most commonly used autografts for anterior cruciate ligament reconstruction are the bone-patellar tendon-bone and hamstring tendons. Each has its advantages and limitations. The bone-patellar tendon-bone autograft can lead to more donor-site morbidity, and the hamstring autograft can be unpredictable in size. The quadriceps tendon, with or without a bone block, has been described as an alternative graft source and has been used especially in revision cases, but in recent years, it has attracted attention even for primary cases. We report a technique for harvesting a free bone quadriceps tendon graft and attaching an extracortical button for femoral fixation for anterior cruciate ligament reconstruction.

  8. A Biomechanical Comparison of Allograft Tendons for Ligament Reconstruction.

    PubMed

    Palmer, Jeremiah E; Russell, Joseph P; Grieshober, Jason; Iacangelo, Abigail; Ellison, Benjamin A; Lease, T Dylan; Kim, Hyunchul; Henn, R Frank; Hsieh, Adam H

    2017-03-01

    Allograft tendons are frequently used for ligament reconstruction about the knee, but they entail availability and cost challenges. The identification of other tissues that demonstrate equivalent performance to preferred tendons would improve limitations. Hypothesis/Purpose: We compared the biomechanical properties of 4 soft tissue allograft tendons: tibialis anterior (TA), tibialis posterior (TP), peroneus longus (PL), and semitendinosus (ST). We hypothesized that allograft properties would be similar when standardized by the looped diameter. Controlled laboratory study. This study consisted of 2 arms evaluating large and small looped-diameter grafts: experiment A consisted of TA, TP, and PL tendons (n = 47 each) with larger looped diameters of 9.0 to 9.5 mm, and experiment B consisted of TA, TP, PL, and ST tendons (n = 53 each) with smaller looped diameters of 7.0 to 7.5 mm. Each specimen underwent mechanical testing to measure the modulus of elasticity (E), ultimate tensile force (UTF), maximal elongation at failure, ultimate tensile stress (UTS), and ultimate tensile strain (UTε). Experiment A: No significant differences were noted among tendons for UTF, maximal elongation at failure, and UTϵ. UTS was significantly higher for the PL (54 MPa) compared with the TA (44 MPa) and TP (43 MPa) tendons. E was significantly higher for the PL (501 MPa) compared with the TP (416 MPa) tendons. Equivalence testing showed that the TP and PL tendon properties were equivalent or superior to those of the TA tendons for all outcomes. Experiment B: All groups exhibited a similar E. UTF was again highest in the PL tendons (2294 N) but was significantly different from only the ST tendons (1915 N). UTϵ was significantly higher for the ST (0.22) compared with the TA (0.19) and TP (0.19) tendons. Equivalence testing showed that the TA, TP, and PL tendon properties were equivalent or superior to those of the ST tendons. Compared with TA tendons, TP and PL tendons of a given looped

  9. The effect of subtalar inversion/eversion on the dynamic function of the tibialis anterior, soleus, and gastrocnemius during the stance phase of gait.

    PubMed

    Wang, Ruoli; Gutierrez-Farewik, Elena M

    2011-05-01

    The purpose of this study was to determine how gait deviation in one plane (i.e. excessive subtalar inversion/eversion) can affect the dynamic function of the tibialis anterior, gastrocnemius, and soleus to accelerate the subtalar, ankle, knee and hip joints, as well as the body center of mass. Induced acceleration analysis was performed based on a subject-specific three-dimensional linkage model configured by stance phase gait data and driven by one unit of muscle force. Eight healthy adult subjects were examined in gait analysis. The subtalar inversion/eversion was modeled by offsetting up to 20° from the normal subtalar angle while other configurations remained unaltered. This study showed that the gastrocnemius, soleus and tibialis anterior generally functioned as their anatomical definition in normal gait, but counterintuitive function was occasionally found in the bi-articular gastrocnemius. The plantarflexors play important roles in the body support and forward progression. Excessive subtalar eversion was found to enlarge the plantarflexors and tibialis anterior's function. Induced acceleration analysis demonstrated its ability to isolate the contributions of individual muscle to a given factor, and as a means of studying effect of pathological gait on the dynamic muscle functions. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Short-Term effects of neuromuscular electrical stimulation on muscle architecture of the tibialis anterior and gastrocnemius in children with cerebral palsy: preliminary results of a prospective controlled study.

    PubMed

    Karabay, İlkay; Öztürk, Gökhan Tuna; Malas, Fevziye Ünsal; Kara, Murat; Tiftik, Tülay; Ersöz, Murat; Özçakar, Levent

    2015-09-01

    The aim of this study was to explore the short-term effects of neuromuscular electrical stimulation application on tibialis anterior (stimulated muscle) and gastrocnemius (antagonist) muscles' size and architecture in children with cerebral palsy by using ultrasound. This prospective, controlled study included 28 children diagnosed with spastic diplegic cerebral palsy. Participants were treated either with neuromuscular electrical stimulation application and conventional physiotherapy (group A) or with conventional physiotherapy alone (group B). Outcome was evaluated by clinical (gross motor function, selective motor control, range of motion, spasticity) and ultrasonographic (cross-sectional area, pennation angle, fascicle length of tibialis anterior and gastrocnemius muscles) measurements before and after treatment in both groups. Cross-sectional area values of tibialis anterior (238.7 ± 61.5 vs. 282.0 ± 67.1 mm) and gastrocnemius (207.9 ± 48.0 vs. 229.5 ± 52.4 mm) (P < 0.001 and P = 0.008, respectively) muscles were increased after treatment in group A. Cross-sectional area values of tibialis anterior muscle were decreased (257.3 ± 64.7 vs. 239.7 ± 60.0 mm) after treatment in group B (P < 0.001), and the rest of the measurements were found not to have changed significantly in either group. These results have shown that cross-sectional area of both the agonist and antagonist muscles increased after 20 sessions of neuromuscular electrical stimulation treatment. Future studies with larger samples and longer follow-up are definitely awaited for better evaluation of neuromuscular electrical stimulation application on muscle architecture and its possible correlates in clinical/functional outcome.

  11. Limited fiber type grouping in self-reinnervation cat tibialis anterior muscles.

    PubMed

    Unguez, G A; Roy, R R; Bodine-Fowler, S; Edgerton, V R

    1996-10-01

    The percent and distribution patterns of three immunohistochemically identified fiber types within the anterior compartment of the cat tibialis anterior were determined 6 months after denervation and self-reinnervation. After self-reinnervation, mean frequencies of slow (9%) and fast (91%) fibers were similar to those in control (12% and 88%, respectively) muscles. However, a lower proportion of fast-1 (26%) and a higher proportion of fast-2 (65%) fibers were observed in self-reinnervated than control (32% and 56%) muscles. Quantitation of adjacencies between fibers of similar myosin heavy chain (MHC) phenotype, a measure of type grouping, revealed that the frequencies of two slow or two fast-1 fibers being adjacent in self-reinnervated muscles were similar to control. In contrast, the frequency of fast-2/fast-2 fiber adjacencies found in self-reinnervated muscles (45%) was significantly higher than in control muscles (37%). In both groups, the frequency of adjacencies between slow, fast-1, or fast-2 fibers was largely attributable to the number of each fiber type present. These data show that the incidence of grouping within each fiber type present was not altered after 6 months of self-reinnervation. Minimal changes in the spatial distribution of fiber types following self-reinnervation in adults suggests a limited degree of conversion of muscle fibers to a MHC phenotype matching the motoneuron characteristics.

  12. Evidence of accumulated stress in Achilles and anterior knee tendons in elite badminton players.

    PubMed

    Boesen, Anders Ploug; Boesen, Morten Ilum; Koenig, Merete Juhl; Bliddal, Henning; Torp-Pedersen, Soren; Langberg, Henning

    2011-01-01

    Tendon-related injuries are a major problem, but the aetiology of tendinopathies is unknown. In tendinopathies as well as during unaccustomed loading, intra-tendinous flow can be detected indicating that extensive loading can provoke intra-tendinous flow. The aim of present study is to evaluate the vascular response as indicated by colour Doppler (CD) activity in both the Achilles and patella tendon after loading during high-level badminton matches. The Achilles tendon was subdivided into a mid-tendon, pre-insertional, and insertional region and the anterior knee tendons into a quadriceps-, patella- and tuberositas region. Intra-tendinous flow was measured using both a semi-quantitative grading system (CD grading) and a quantitative scoring system (CF) on colour Doppler. Intra-tendinous flow in the Achilles and anterior knee tendons was examined in fourteen single players before tournament and after 1st and 2nd match, respectively on both the dominant and non-dominant side. All players had abnormal intra-tendinous flow (Colour Doppler ≥ grade 2) in at least one tendon in at least one scan during the tournament. At baseline, only two of the 14 players had normal flow in all the tendons examined. After 1st match, tendencies to higher intra-tendinous flow were observed in both the dominant patella tendon and non-dominant quadriceps tendon (P-values n.s.). After 2nd match, intra-tendinous flow was significant increased in the dominant patella tendon (P = 0.009). In all other locations, there was a trend towards a stepwise increase in intra-tendinous flow. The preliminary results indicate that high amount of intra-tendinous flow was found in elite badminton players at baseline and was increased after repetitive loading, especially in the patella tendon (dominant leg). The colour Doppler measurement can be used to determine changes in intra-tendinous flow after repetitive loading.

  13. Effects of tibialis anterior vibration on postural control when exposed to support surface translations.

    PubMed

    Temple, David R; Lee, Beom-Chan; Layne, Charles S

    2016-03-01

    The sensory re-weighting theory suggests unreliable inputs may be down-weighted to favor more reliable sensory information and thus maintain proper postural control. This study investigated the effects of tibialis anterior (TA) vibration on center of pressure (COP) motion in healthy individuals exposed to support surface translations to further explore the concept of sensory re-weighting. Twenty healthy young adults stood with eyes closed and arms across their chest while exposed to randomized blocks of five trials. Each trial lasted 8 s, with TA vibration either on or off. After 2 s, a sudden backward or forward translation occurred. Anterior-posterior (A/P) COP data were evaluated during the preparatory (first 2 s), perturbation (next 3 s), and recovery (last 3 s) phases to assess the effect of vibration on perturbation response features. The knowledge of an impending perturbation resulted in reduced anterior COP motion with TA vibration in the preparatory phase relative to the magnitude of anterior motion typically observed during TA vibration. During the perturbation phase, vibration did not influence COP motion. However, during the recovery phase vibration induced greater anterior COP motion than during trials without vibration. The fact that TA vibration produced differing effects on COP motion depending upon the phase of the perturbation response may suggest that the immediate context during which postural control is being regulated affects A/P COP responses to TA vibration. This indicates that proprioceptive information is likely continuously re-weighted according to the context in order to maintain effective postural control.

  14. Quadriceps Tendon Autograft in Anterior Cruciate Ligament Reconstruction: A Systematic Review.

    PubMed

    Hurley, Eoghan T; Calvo-Gurry, Manuel; Withers, Dan; Farrington, Shane K; Moran, Ray; Moran, Cathal J

    2018-05-01

    To systematically review the current evidence to ascertain whether quadriceps tendon autograft (QT) is a viable option in anterior cruciate ligament reconstruction. A literature review was conducted in accordance with Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. Cohort studies comparing QT with bone-patellar tendon-bone autograft (BPTB) or hamstring tendon autograft (HT) were included. Clinical outcomes were compared, with all statistical analyses performed using IBM SPSS Statistics for Windows, version 22.0, with P < .05 being considered statistically significant. We identified 15 clinical trials with 1,910 patients. In all included studies, QT resulted in lower rates of anterior knee pain than BPTB. There was no difference in the rate of graft rupture between QT and BPTB or HT in any of the studies reporting this. One study found that QT resulted in greater knee stability than BPTB, and another study found increased stability compared with HT. One study found that QT resulted in improved functional outcomes compared with BPTB, and another found improved outcomes compared with HT, but one study found worse outcomes compared with BPTB. Current literature suggests QT is a viable option in anterior cruciate ligament reconstruction, with published literature showing comparable knee stability, functional outcomes, donor-site morbidity, and rerupture rates compared with BPTB and HT. Level III, systematic review of Level I, II, and III studies. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  15. Computational model to investigate the relative contributions of different neuromuscular properties of tibialis anterior on force generated during ankle dorsiflexion.

    PubMed

    Siddiqi, Ariba; Poosapadi Arjunan, Sridhar; Kumar, Dinesh Kant

    2018-01-16

    This study describes a new model of the force generated by tibialis anterior muscle with three new features: single-fiber action potential, twitch force, and pennation angle. This model was used to investigate the relative effects and interaction of ten age-associated neuromuscular parameters. Regression analysis (significance level of 0.05) between the neuromuscular properties and corresponding simulated force produced at the footplate was performed. Standardized slope coefficients were computed to rank the effect of the parameters. The results show that reduction in the average firing rate is the reason for the sharp decline in the force and other factors, such as number of muscle fibers, specific force, pennation angle, and innervation ratio. The fast fiber ratio affects the simulated force through two significant interactions. This study has ranked the individual contributions of the neuromuscular factors to muscle strength decline of the TA and identified firing rate decline as the biggest cause followed by decrease in muscle fiber number and specific force. The strategy for strength preservation for the elderly should focus on improving firing rate. Graphical abstract Neuromuscular properties of Tibialis Anterior on force generated during ankle dorsiflexion.

  16. A model for generating Surface EMG signal of m. Tibialis Anterior.

    PubMed

    Siddiqi, Ariba; Kumar, Dinesh; Arjunan, Sridhar P

    2014-01-01

    A model that simulates surface electromyogram (sEMG) signal of m. Tibialis Anterior has been developed and tested. This has a firing rate equation that is based on experimental findings. It also has a recruitment threshold that is based on observed statistical distribution. Importantly, it has considered both, slow and fast type which has been distinguished based on their conduction velocity. This model has assumed that the deeper unipennate half of the muscle does not contribute significantly to the potential induced on the surface of the muscle and has approximated the muscle to have parallel structure. The model was validated by comparing the simulated and the experimental sEMG signal recordings. Experiments were conducted on eight subjects who performed isometric dorsiflexion at 10, 20, 30, 50, 75, and 100% maximal voluntary contraction. Normalized root mean square and median frequency of the experimental and simulated EMG signal were computed and the slopes of the linearity with the force were statistically analyzed. The gradients were found to be similar (p>0.05) for both experimental and simulated sEMG signal, validating the proposed model.

  17. PT-12, a putative ras-activated proliferation-dependent gene, is expressed in patellar tendon and not in anterior cruciate ligament.

    PubMed

    Goomer, R S; Maris, T; Ostrander, R; Amiel, D

    1999-09-01

    We describe a gene (PT-12) that is expressed in the patellar tendon and not in the anterior cruciate ligament. We used a recently developed polymerase chain reaction-based subtractive cDNA analysis to discover genes that are overexpressed in the patellar tendon but not expressed in the anterior cruciate ligament; the long-term objective was to find genes that are central to the self-repair of the patellar tendon, in contrast with the inability of the anterior cruciate ligament to launch a repair response following injury. PT-12 is a homologue of human S2 or mouse LLRep3 ribosomal genes, which are known to be overexpressed in highly proliferating cells. This study opens a new vista to the development of techniques and reagents to study the differences between two periarticular tissues (i.e., the patellar tendon and anterior cruciate ligament) that differ primarily in their ability to self-repair.

  18. Half-peroneus-longus-tendon graft augmentation for unqualified hamstring tendon graft of anterior cruciate ligament reconstruction.

    PubMed

    Liu, Chung-Ting; Lu, Yung-Chang; Huang, Chang-Hung

    2015-09-01

    In some situations, harvested hamstring tendon grafts are not qualified for anterior cruciate ligament (ACL) reconstruction. This study aimed to present a reinforcing method with additional half peroneus longus tendon (half-PLT) graft augmentation. Eight cases underwent ACL reconstruction with unqualified hamstring tendon grafts (diameter <7 mm) and were salvaged by additional half-PLT graft augmentation. The pivot shift test and KT-1000 tests were performed 3 years after surgery. Functional evaluation of subjective International Knee Documentation Committee (IKDC) and Lysholm scores was also done. In addition, Foot and Ankle Disability Index (FADI) scores were used to evaluate the function of the ankle donor site. The diameter of unqualified four-strand hamstring tendon grafts was 6.2 mm on average (range, 6.0-6.5 mm). The average diameter of hamstring grafts with half-PLT augmentation was 9.6 mm (range, 9.5-10.0 mm). The pivot shift test was negative in all patients. No significant differences between normal and abnormal knees were found by KT-1000. The average IKDC score was 86.0 (range, 83 to 89), and the average Lysholm score was 84.4 (range, 80-90). The average FADI score for the donor sites of half-PLT was 135.8 (range, 134-136). Additional half-PLT can successfully and safely reinforce unqualified hamstring tendon grafts for ACL reconstruction.

  19. Measuring tendon properties in mdx mice: cell viability and viscoelastic characteristics.

    PubMed

    Rizzuto, E; Musarò, A; Catizone, A; Del Prete, Z

    2009-10-16

    Muscular dystrophy is a genetic disorder of skeletal muscle characterized by progressive muscle weakness. Here we assessed whether muscle wasting affects cell viability and mechanical properties of extensor digitorum longus (EDL) and of tibialis anterior (TA) tendons from mdx dystrophic mice compared to wild type (WT) mice. mdx mice represent the classical animal model for human Duchenne muscular dystrophy, and show several signs of the pathology, including a decrease in specific force and an increase of fibrotic index. Cell viability of tendons was evaluated by histological analysis, and viscoelastic properties have been assessed by a rapid measurement protocol that allowed us to compute, at the same time, tissue complex compliance for all the frequencies of interest. Confocal microscopy and mechanical properties measurements revealed that mdx tendons, compared to WT ones, have an increase in the number of dead cells and a significant reduction in tissue elasticity for all the frequencies that were tested. These findings indicate a reduced quality of the tissue. Moreover, mdx tendons have an increase in the viscous response, indicating that during dynamic loading, they dissipate more energy compared to WT. Our results demonstrate that muscular dystrophy involves not only muscle wasting, but also alteration in the viscoelastic properties of tendons, suggesting a paracrine effect of altered skeletal muscle on tendinous tissue.

  20. Age related neuromuscular changes in sEMG of m. Tibialis Anterior using higher order statistics (Gaussianity & linearity test).

    PubMed

    Siddiqi, Ariba; Arjunan, Sridhar P; Kumar, Dinesh K

    2016-08-01

    Age-associated changes in the surface electromyogram (sEMG) of Tibialis Anterior (TA) muscle can be attributable to neuromuscular alterations that precede strength loss. We have used our sEMG model of the Tibialis Anterior to interpret the age-related changes and compared with the experimental sEMG. Eighteen young (20-30 years) and 18 older (60-85 years) performed isometric dorsiflexion at 6 different percentage levels of maximum voluntary contractions (MVC), and their sEMG from the TA muscle was recorded. Six different age-related changes in the neuromuscular system were simulated using the sEMG model at the same MVCs as the experiment. The maximal power of the spectrum, Gaussianity and Linearity Test Statistics were computed from the simulated and experimental sEMG. A correlation analysis at α=0.05 was performed between the simulated and experimental age-related change in the sEMG features. The results show the loss in motor units was distinguished by the Gaussianity and Linearity test statistics; while the maximal power of the PSD distinguished between the muscular factors. The simulated condition of 40% loss of motor units with halved the number of fast fibers best correlated with the age-related change observed in the experimental sEMG higher order statistical features. The simulated aging condition found by this study corresponds with the moderate motor unit remodelling and negligible strength loss reported in literature for the cohorts aged 60-70 years.

  1. Incidence and Association of CT Findings of Ankle Tendon Injuries in Patients Presenting With Ankle and Hindfoot Fractures.

    PubMed

    Golshani, Ashkahn; Zhu, Liang; Cai, Chunyan; Beckmann, Nicholas M

    2017-02-01

    Tendon injuries are a commonly encountered finding in ankle CT examinations performed for fractures. This study was designed to identify the incidence and associations of tendon injuries in ankle CT examinations performed for fractures. A retrospective review was performed of 410 patients who underwent ankle CT during a 6-year period. Tendon injuries were common, seen in 25% of all ankle CT examinations. Tendon subluxation-dislocation accounted for most of the tendon injuries (77 of 196 total injuries). Pilon fractures carried 2.2 times increased risk of tibialis posterior tendon injury (p = 0.0094). Calcaneus fractures carried 11.86 times increased risk of peroneus brevis tendon and 10.71 times increased risk of peroneus longus tendon injury (p < 0.0001). Calcaneus fractures also carried 5.21 times increased risk of flexor hallucis longus tendon injury (p = 0.0024). Talus fracture was associated with injury to all flexor compartment tendons. Talus fractures carried 3.43 times increased risk of tibialis posterior tendon injury (p < 0.0001), 4.51 times increased risk of flexor digitorum longus tendon injury (p = 0.0005), and 6.97 times increased risk of flexor hallucis longus tendon injury (p < 0.0001). Calcaneal fractures are prone to peroneal tendon injury, and talus fractures are prone to flexor tendon injury. In patients with pilon fractures, it is important to look for tibialis posterior tendon injury, specifically for entrapment. Overall, the most common type of injury is tendon malalignment, so it is imperative to know the normal tendon paths and associated bony landmarks to identify tendon injury.

  2. IS THERE ANY ROOM FOR TENDOSCOPY IN THE SURGICAL TREATMENT OF POSTERIOR TIBIAL TENDON INSUFFICIENCY?

    PubMed

    Bojanić, Ivan; Dimnjaković, Damjan; Mahnik, Alan; Smoljanović, Tomislav

    2016-05-01

    Posterior tibial tendon insufficiency (PTTI) is nowadays considered to be the main cause of adult-acquired flatfoot deformity (AAFD). The purpose of this study is to report the outcomes of tendoscopic treatment of tibialis poste- rior tendon (TP) in eleven patients with stage 1 or 2 PTTI and failed prior conservative treatment. Tendoscopy was carried out as a solitary procedure in 8 patients, while in 3 patients additional procedures such as ,,mini-open" tubularization of TP or anterior ankle arthroscopy were necessary. In a single patient transfer of flexor digitorum longus tendon was performed as a second stage surgery due to complete rupture of TP. Related with tendoscopic procedure, no complications were re- ported. TP tendoscopy is a useful and beneficial minimally invasive procedure to treat TP pathology at earlier stages of PTTI. It is a technically demanding procedure that requires extensive experience in arthroscopic management of small ioints and excellent knowledge of repional anatomy.

  3. Electromechanical delay of the knee flexor muscles is impaired after harvesting hamstring tendons for anterior cruciate ligament reconstruction.

    PubMed

    Ristanis, Stavros; Tsepis, Elias; Giotis, Dimitrios; Stergiou, Nicholas; Cerulli, Guiliano; Georgoulis, Anastasios D

    2009-11-01

    Changes in electromechanical delay during muscle activation are expected when there are substantial alterations in the structural properties of the musculotendinous tissue. In anterior cruciate ligament reconstruction, specific tendons are being harvested for grafts. Thus, there is an associated scar tissue development at the tendon that may affect the corresponding electromechanical delay. This study was conducted to investigate whether harvesting of semitendinosus and gracilis tendons for anterior cruciate ligament reconstruction will affect the electromechanical delay of the knee flexors. Case-control study; Level of evidence, 3. The authors evaluated 12 patients with anterior cruciate ligament reconstruction with a semitendinosus and gracilis autograft, 2 years after the reconstruction, and 12 healthy controls. Each participant performed 4 maximally explosive isometric contractions with a 1-minute break between contractions. The surface electromyographic activity of the biceps femoris and the semitendinosus was recorded from both legs during the contractions. The statistical comparisons revealed significant increases of the electromechanical delay of the anterior cruciate ligament-reconstructed knee for both investigated muscles. Specifically, the electromechanical delay values were increased for both the biceps femoris (P = .029) and the semitendinosus (P = .005) of the reconstructed knee when compared with the intact knee. Comparing the anterior cruciate ligament-reconstructed knee against healthy controls revealed similar significant differences for both muscles (semitendinosus, P = .011; biceps femoris, P = .024). The results showed that harvesting the semitendinosus and gracilis tendons for anterior cruciate ligament reconstruction significantly increased the electromechanical delay of the knee flexors. Increased hamstring electromechanical delay might impair knee safety and performance by modifying the transfer time of muscle tension to the tibia and

  4. Hydroxyapatite-doped polycaprolactone nanofiber membrane improves tendon-bone interface healing for anterior cruciate ligament reconstruction.

    PubMed

    Han, Fei; Zhang, Peng; Sun, Yaying; Lin, Chao; Zhao, Peng; Chen, Jiwu

    2015-01-01

    Hamstring tendon autograft is a routine graft for anterior cruciate ligament (ACL) reconstruction. However, ways of improving the healing between the tendon and bone is often overlooked in clinical practice. This issue can be addressed by using a biomimetic scaffold. Herein, a biomimetic nanofiber membrane of polycaprolactone/nanohydroxyapatite/collagen (PCL/nHAp/Col) is fabricated that mimics the composition of native bone tissue for promoting tendon-bone healing. This membrane has good cytocompatibility, allowing for osteoblast cell adhesion and growth and bone formation. As a result, MC3T3 cells reveal a higher mineralization level in PCL/nHAp/Col membrane compared with PCL membrane alone. Further in vivo studies in ACL reconstruction in a rabbit model shows that PCL/nHAp/Col-wrapped tendon may afford superior tissue integration to nonwrapped tendon in the interface between the tendon and host bone as well as improved mechanical strength. This study shows that PCL/nHAp/Col nanofiber membrane wrapping of autologous tendon is effective for improving tendon healing with host bone in ACL reconstruction.

  5. [Isokinetic assessment with two years follow-up of anterior cruciate ligament reconstruction with patellar tendon or hamstring tendons].

    PubMed

    Condouret, J; Cohn, J; Ferret, J-M; Lemonsu, A; Vasconcelos, W; Dejour, D; Potel, J-F

    2008-12-01

    This retrospective multicentric study was designed to assess the outcome of quadriceps and hamstrings muscles two years after Anterior Cruciate Ligament (ACL) reconstruction and compare muscles recovery depending on the type of graft and individual variables like age, gender, level of sport, but also in terms of discomfort, pain and functional score. The results focused on the subjective and objective IKDC scores, SF36, the existence or not of subjective disorders and their location. The review included isokinetic muscle tests concentric and eccentric extensors/flexors but also internal rotators/external rotators with analysis of mean work and mean power. One hundred and twenty-seven patients were included with an average age 29 years (+/-10). They all had an ACL reconstruction with patellar tendon or hamstring tendon with single or double bundles. In the serie, the average muscles deficit at two years was 10% for the flexors and extensors but with a significant dispersion. Significant differences were not noted in the mean values of all parameters in term of sex or age (over 30 years or not), neither the type of sport, nor of clinical assessment (Class A and B of objective IKDC score), nor the existence of anterior knee pain. There was a relationship between the level of extensor or flexor recovery and the quality of functional results with minimal muscle deficits close to 5% if the IKDC score was over 90 and deficits falling to 15% in the group with IKDC score less than 90. The type of reconstruction (patellar tendon versus hamstrings) had an influence on the muscle deficit. For extensors, the recovery was the same in the two groups, more than 90% at two years and the distribution of these two populations by level of deficit was quite the same. For flexors, residual deficits were significantly higher in the hamstrings group on the three studied parameters whatever the speed and the type of contraction (concentric or eccentric) with an average deficit of 14 to 18

  6. The biomechanical effects of limb lengthening and botulinum toxin type A on rabbit tendon.

    PubMed

    Olabisi, Ronke M; Best, Thomas M; Hurschler, Christof; Vanderby, Ray; Noonan, Kenneth J

    2010-12-01

    Numerous studies have examined the effects of distraction osteogenesis (DO) on bone, but relatively fewer have explored muscle adaptation, and even less have addressed the concomitant alterations that occur in the tendon. The purpose herein was to characterize the biomechanical properties of normal and elongated rabbit (N = 20) tendons with and without prophylactic botulinum toxin type A (BTX-A) treatment. Elastic and viscoelastic properties of Achilles and Tibialis anterior (TA) tendons were evaluated through pull to failure and stress relaxation tests. All TA tendons displayed nonlinear viscoelastic responses that were strain dependent. A power law formulation was used to model tendon viscoelastic responses and tendon elastic responses were fit with a microstructural model. Distraction-elongated tendons displayed increases in compliance and stress relaxation rates over undistracted tendons; BTX-A administration offset this result. The elastic moduli of distraction-lengthened TA tendons were diminished (p = 0.010) when distraction was combined with gastrocnemius (GA) BTX-A administration, elastic moduli were further decreased (p = 0.004) and distraction following TA BTX-A administration resulted in TA tendons with moduli not different from contralateral control (p > 0.05). Compared to contralateral control, distraction and GA BTX-A administration displayed shortened toe regions, (p = 0.031 and 0.038, respectively), while tendons receiving BTX-A in the TA had no differences in the toe region (p > 0.05). Ultimate tensile stress was unaltered by DO, but stress at the transition from the toe to the linear region of the stress-stretch curve was diminished in all distraction-elongated TA tendons (p < 0.05). The data suggest that prophylactic BTX-A treatment to the TA protects some tendon biomechanical properties. Copyright © 2010 Elsevier Ltd. All rights reserved.

  7. Effect of eccentric exercise program for early tibialis posterior tendinopathy.

    PubMed

    Kulig, Kornelia; Lederhaus, Eric S; Reischl, Steve; Arya, Shruti; Bashford, Greg

    2009-09-01

    Morphology and vascularization of painful tibialis posterior (TP) tendons before and after an intervention targeting the degenerated tendon were examined. Functional status and pain level were also assessed. A10-week twice daily, progressive eccentric tendon loading, calf stretching program with orthoses was implemented with ten, early stage TP tendinopathy subjects. TP tendons were imaged by grayscale and Doppler ultrasound at INITIAL and POST evaluations to assess the tendon's morphology and signs of neovascularization. The Foot Functional Index (FFI), Physical Activity Scale (PAS), 5-Minute Walk Test, and single heel raise (SHR) test were completed at INITIAL and POST evaluations. The Global Rating Scale (GRS) was completed at 6 months followup. One-way ANOVA was used to compare the FFI at INITIAL, POST, and 6-MONTH time points. Paired t-tests were used to compare means between the remaining variables. The level of significance was p = 0.05. There was a significant difference in FFI total, pain, and disability at the three time-points. Post-hoc paired t-tests revealed that the FFI scores were lower for the total score and pain and disability subcategories when comparing from INITIAL to POST and INITIAL to 6-MONTH evaluations (p < 0.05 for all). The number of SHR increased significantly on the involved side from INITIAL to POST evaluation (p = 0.041). The GRS demonstrated minimum clinically important differences for improvements in symptoms at 6-MONTH. Tendon morphology and vascularization remained abnormal following the intervention. A 10-week tendon specific eccentric program resulted in improvements in symptoms and function without changes in tendon morphology or neovascularization.

  8. Tissue oxygen partial pressure in the tibialis anterior muscle in patients with claudication before, during and after a two-stage treadmill stress test.

    PubMed

    Jung, F; Krüger, A; Pindur, G; Sternitzky, R; Franke, R P; Gori, T

    2014-01-01

    The role of the microcirculation in the pathophysiology and symptoms of peripheral arterial obliterative disease (PAOD) has been progressively emphasized during the past decades. Under resting conditions, already, the tissue oxygen partial pressure in the m. tibialis anterior (pO2im) is reduced to about 50% compared to healthy subjects. In the framework of this study the pO2im of patients with PAOD stage II according to Fontaine (n=16) in the m. tibialis anterior was measured under resting conditions and during walking on a treadmill in comparison to healthy subjects (n=10). Under resting conditions the pO2im only marginally differed between PAOD patients and healthy subjects. But during exercise the pO2im dropped significantly more severely in PAOD patients and a return to baseline values could only be reached when the treadmill was stopped and the patients stood still. The pO2im minima correlated clearly with the clinical symptom of calf pain. The data revealed that the pO2im values were lower in PAOD patients and dropped significantly faster during walking compared to the pO2im values in healthy subjects. The pO2im decrease correlated with the calf pain occurring when the pO2im values approached or fell below 10 mmHg.

  9. Knee isokinetic performance following anterior cruciate ligament reconstruction: patellar tendon versus hamstrings graft.

    PubMed

    Machado, Felipe; Debieux, Pedro; Kaleka, Camila Cohen; Astur, Diego; Peccin, Maria Stella; Cohen, Moisés

    2018-02-01

    To compare knee isokinetic performance six months after reconstruction of the anterior cruciate ligament using grafts from either the patellar tendon or the hamstrings among patients who underwent the same rehabilitation protocol. Thirty-four patients were evaluated (17 with grafts from the patellar tendon and 17 with grafts from the hamstrings). Operated and non-operated knees were compared with regards to the variables of peak torque, work and the hamstring/quadriceps relationship at velocities of 60º/s and 180º/s and power of 180º/s after six months of surgery. The patients with ACL reconstruction using the patellar tendon (BPTB) showed quadriceps deficits for all variables, but the flexor musculature was balanced. In the hamstring group, both the extensors and the flexors showed deficits for the variables analyzed, except for hamstring power at 180º/s. Patients in the patellar tendon group had a greater quadriceps deficit compared with those in the hamstrings group. Patients in the hamstrings group had a greater muscular deficit in the flexor mechanism compared with the contralateral knee. An unbalanced H/Q ratio was observed regardless of graft type, but this was more evident in the BPTB group.

  10. Interosseous nerve transfers for tibialis anterior muscle paralysis (foot drop): a human cadaver-based feasibility study.

    PubMed

    Pirela-Cruz, Miguel A; Hansen, Uel; Terreros, Daniel A; Rossum, Alfred; West, Priscilla

    2009-03-01

    This study explored the anatomical feasibility of using an interosseous nerve transfer (routed between the tibia and fibula) to restore motor function to the tibialis anterior (TA) muscle, following injury to the common peroneal nerve (resulting in a foot drop). The specific nerve branches evaluated as possible donor nerves included the nerves to the medial gastrocnemius, the lateral gastrocnemius, and the soleus muscles. All nerve transfers were accomplished using a direct interosseous route and a direct repair (one medial gastrocnemius transfer did require interpositional grafting). The distance from the repair site to the TA muscle was shortest for the transfer using the nerve branch to the soleus. Histologically, the nerve branch to the soleus was most similar to the branch to the TA for both axonal count and cross-sectional area. A two-incision surgical approach using a fibular window (mobilizing a fibular segment after double osteotomy) and interosseous routing of the transfer is proposed.

  11. Changes in the estimated time course of the motoneuron afterhyperpolarization induced by tendon vibration.

    PubMed

    MacDonell, Christopher W; Ivanova, Tanya D; Garland, S Jayne

    2010-12-01

    Group Ia afferents are activated vigorously with high-frequency tendon vibration and provide excitatory input to the agonist muscle and inhibitory input to the antagonist muscle group via inhibitory interneurons. The purpose of this experiment was to determine whether the afterhyperpolarization (AHP) time course in humans is altered in response to tendon vibration. The AHP time course is estimated using the interval death rate (IDR) analysis, a transform of the motor unit action potential train. Single motor units from tibialis anterior (TA) were recorded as subjects held low force dorsiflexor contractions for 600 s with and without vibration. The vibratory stimulus was superimposed on the low force contraction either to the tendon of the TA or the antagonist Achilles tendon. During TA tendon vibration, the time course of the AHP, as expressed by its time constant (τ), decreased from 35.5 ms in the previbration control condition to 31.3 ms during the vibration (P = 0.003) and returned to 36.3 ms after the vibration was removed (P = 0.002). The AHP τ during vibration of the antagonist Achilles tendon (38.6 ms) was greater than the previbration control condition (33.6 ms; P = 0.001). It is speculated that the reduction in AHP time constant with TA vibration may have resulted alone or in combination with a modulation of motoneuron gain, an alteration of persistent inward currents and/or the restructuring of synaptic noise. A decrease in firing probability, possibly reflecting Ia reciprocal inhibition, may have been responsible for the larger AHP time constant.

  12. Age-Associated Changes in the Spectral and Statistical Parameters of Surface Electromyogram of Tibialis Anterior.

    PubMed

    Siddiqi, Ariba; Arjunan, Sridhar Poosapadi; Kumar, Dinesh Kant

    2016-01-01

    Age-related neuromuscular change of Tibialis Anterior (TA) is a leading cause of muscle strength decline among the elderly. This study has established the baseline for age-associated changes in sEMG of TA at different levels of voluntary contraction. We have investigated the use of Gaussianity and maximal power of the power spectral density (PSD) as suitable features to identify age-associated changes in the surface electromyogram (sEMG). Eighteen younger (20-30 years) and 18 older (60-85 years) cohorts completed two trials of isometric dorsiflexion at four different force levels between 10% and 50% of the maximal voluntary contraction. Gaussianity and maximal power of the PSD of sEMG were determined. Results show a significant increase in sEMG's maximal power of the PSD and Gaussianity with increase in force for both cohorts. It was also observed that older cohorts had higher maximal power of the PSD and lower Gaussianity. These age-related differences observed in the PSD and Gaussianity could be due to motor unit remodelling. This can be useful for noninvasive tracking of age-associated neuromuscular changes.

  13. Revision anterior cruciate ligament reconstruction with nonirradiated fresh-frozen patellar tendon allograft.

    PubMed

    Fox, Jeff A; Pierce, Mark; Bojchuk, John; Hayden, Jennifer; Bush-Joseph, Charles A; Bach, Bernard R

    2004-10-01

    To evaluate the effectiveness of a revision anterior cruciate ligament reconstruction with nonirradiated patellar tendon allograft used to salvage a failed index patellar tendon autograft procedure. Retrospective case series with minimum 2-year follow-up. Between 1993 and 1999, 39 patients underwent a revision reconstruction. Clinical, radiographic, arthrometric, and functional evaluations were performed. The Tegner, Lysholm, Noyes, Knee Injury and Osteoarthritis Outcome Score (KOOS), International Knee Documentation Committee (IKDC), and SF-12 rating scales were used. Statistical analysis was conducted with our Biostatistics Department. Thirty-two of 38 patients (84%) were personally evaluated. The mean patient age was 28 years (range, 16 to 57 years); the mean follow-up was 4.8 years (range, 2.1 to 12.1 years). After revision, there were significant improvements in the Lachman and pivot-shift test results: 87% had a grade 0/1+ Lachman and a 0/1+ pivot-shift. However, 25% had a grade 1+ pivot-shift. Postoperatively, KT-1000 testing revealed that 84% had a maximum manual side-to-side difference of < or =3 mm and 6% had >5 mm. Functional testing revealed a mean 4% difference in side-to-side comparisons for a single-leg hop for distance and time, as well as vertical jump. The mean results of Noyes sports function (72), Lysholm (75), Tegner (6.3), KOOS sports activity scale (67), SF-12 physical component (48), SF-12 mental component (55), and IKDC (71) were obtained. The Noyes sports activity score showed a significant improvement from 55 preoperatively to 70 at follow-up. Subjectively, 87% of patients indicated that they were completely or mostly satisfied with the surgical outcome. One patient required another revision. The 2- to 11-year follow-up showed that the results of revision ACL reconstruction with a nonirradiated patellar tendon allograft were less favorable than those of a primary anterior cruciate ligament reconstruction, with a lower subjective

  14. Tensile properties of a morphologically split supraspinatus tendon.

    PubMed

    Matsuhashi, Tomoya; Hooke, Alexander W; Zhao, Kristin D; Goto, Akira; Sperling, John W; Steinmann, Scott P; An, Kai-Nan

    2014-07-01

    The supraspinatus tendon consists morphologically of two sub-regions, anterior and posterior. The anterior sub-region is thick and tubular while the posterior is thin and strap-like. The purpose of this study was to compare the structural and mechanical properties of the anterior and posterior sub-regions of the supraspinatus tendon. The supraspinatus tendons from seven human cadaveric shoulders were morphologically divided into the anterior and posterior sub-regions. Length, width, and thickness were measured. A servo-hydraulic testing machine (MTS Systems Corporation, Minneapolis, MN) was used for tensile testing. The maximal load at failure, modulus of elasticity and ultimate tendon stress were calculated. Repeated measures were used for statistical comparisons. The mean anterior tendon cross-sectional area was 47.3 mm(2) and the posterior was 32.1 mm(2) . Failure occurred most often at the insertion site: anterior (5/7) and posterior (6/7). All parameters of the anterior sub-region were significantly greater than those of the posterior sub-region. The moduli of elasticity at the insertion site were 592.4 MPa in the anterior sub-region and 217.7 MPa in the posterior (P = 0.01). The ultimate failure loads were 779.2 N in the anterior sub-region and 335.6 N in the posterior (P = 0.003). The ultimate stresses were 22.1 MPa in the anterior sub-region and 11.6 MPa in the posterior (P = 0.008). We recognized that the anterior and posterior sub-regions of the SSP tendon have significantly different mechanical properties. In a future study, we need to evaluate how best to repair an SSP tendon considering these region-specific properties. Copyright © 2013 Wiley Periodicals, Inc.

  15. All-Inside Single-Bundle Reconstruction of the Anterior Cruciate Ligament with the Anterior Half of the Peroneus Longus Tendon Compared to the Semitendinosus Tendon: A Two-Year Follow-Up Study.

    PubMed

    Bi, Mingguang; Zhao, Chen; Zhang, Shuijun; Yao, Bin; Hong, Zheping; Bi, Qing

    2018-02-08

    The anterior half of the peroneus longus tendon (AHPLT) has been reported to be acceptable for ligament reconstruction with respect to strength and safety. However, there is little information regarding the clinical outcomes after using the AHPLT compared with other autograft tendons. A prospective randomized controlled study was performed to compare the results of 62 cases of all-inside anatomical single-bundle anterior cruciate ligament (ACL) reconstruction using the AHPLT and 62 cases using semitendinosus graft with an average of 30.0 ± 3.6 months' follow-up. Tunnel placements of enrolled cases were measured on three-dimensional (3D) computed tomography (CT) and X-ray imaging. Knee stability was assessed using the anterior drawer test, pivot shift test, and KT-1000. The International Knee Documentation Committee (IKDC) 2000 subjective score was used to evaluate functional outcomes. The American Orthopedic Foot and Ankle Score (AOFAS) and the assessment of eversion muscle strength were performed to evaluate the function of the ankle donor site. Tunnel positions, which were confirmed with 3D CT, were in the anatomical positions. At the final follow-up, there were no significant differences between the semitendinosus group and the AHPLT group in the IKDC score (90.4 ± 7.1 vs. 89.3. ± 8.4), KT 1000 measurements (1.71 ± 0.57 vs. 1.85 ± 0.77), pivot shift test, and Visual Analogue Scale (VAS) (0.15 ± 0.36 vs. 0.10 ± 0.30). No obvious ankle site complications were found at 24 months. The average AOFAS score of the AHPLT group was comparable to that of the semitendinosus tendon group (99.1 ± 1.40 vs. 99.5 ± 1.21). There was no significant difference in clinical outcomes or knee stability between the semitendinosus group and the AHPLT group at the 2-year follow-up. An AHPLT autograft may be a good alternative for all-inside ACL reconstruction with respect to its strength, safety, and donor site morbidity. Thieme Medical

  16. Revision anterior cruciate ligament reconstruction by double-bundle technique using multi-strand semitendinosus tendon.

    PubMed

    Muneta, Takeshi; Hara, Kenji; Ju, Young-Jin; Mochizuki, Tomoyuki; Morito, Toshiyuki; Yagishita, Kazuyoshi; Sekiya, Ichiro

    2010-06-01

    The purpose of the study was to compare the outcome of revision anterior cruciate ligament (ACL) reconstruction by the double-bundle (DB) technique using multi-strand semitendinosus tendon with that of primary reconstruction by use of the same technique. The study included 21 patients who underwent revision ACL reconstruction (mean follow-up, 40 months) with the semitendinosus tendon DB technique between 1995 and 2006 and 86 unilateral primary DB ACL reconstructions (mean follow-up, 33 months) between 2000 and 2004. The outcome of both groups was compared based on differences between operated and unoperated limbs and modified International Knee Documentation Committee grades. Both the overall and sports-related subjective scores were evaluated between the 2 groups. The KT measurements (MEDmetric, San Diego, CA) averaged 1.7 mm (SD, 1.8 mm) in the revision group and 1.5 mm (SD, 1.6 mm) in the primary group. There was no significant difference in KT measurements between the 2 groups. The Lachman test was negative in 83% of revision cases and 87% of primary cases; the anterior drawer test was negative in 83% and 91%, respectively, and the pivot-shift test was negative in 78% and 90%, respectively. There was a tendency for a positive pivot-shift test in the revision group being higher. The Lysholm score and subjective recovery score were significantly lower in the revision group. The semitendinosus tendon DB revision procedure provided range of motion and anterior stability comparable to those after primary DB surgery and a comparable return to athletic activities. However, the patients tended to have positive pivot-shift test results. The revision cases were also inferior in terms of the general evaluation of recovery of knee condition. The outcome scores were lower overall in the revision group. Level IV, therapeutic case series. Copyright (c) 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. Regional strain variations in the human patellar tendon.

    PubMed

    Pearson, Stephen J; Ritchings, Tim; Mohamed, Azlan S A

    2014-07-01

    Characteristics of localized tendon strain in vivo are largely unknown. The present study examines local tendon strain between the deep, middle, and surface structures at the proximal and distal aspects of the patellar tendon during ramped isometric contractions. Male subjects (age 28.0 ± 6.3 yr) were examined for patellar tendon excursion (anterior, midsection, and posterior) during ramped isometric voluntary contractions using real-time B-mode ultrasonography and dynamometry. Regional tendon excursion measurements were compared using an automated pixel tracking method. Strain was determined from the tendon delta length normalized to initial/resting segment length. Strain increased from 10% to 100% of force for all regions. Significantly greater mean strain was seen for the anterior proximal region compared to the posterior and mid layer of the tendon (7.5% ± 1.1% vs 3.7% ± 0.5% vs 5.5% ± 1.0%; P < 0.05). Similarly, the distal posterior region showed greater mean strain compared to the mid and anterior regions (7.9% ± 0.6% vs 5.0% ± 0.6% vs 5.4% ± 0.6%; P < 0.05). Relative changes in strain differences from 50% to 100% of force for the proximal region were greatest for the anterior to midline regions (4.6% ± 0.6% and 5.6% ± 0.6%, respectively) and those for the distal region were also greatest for the anterior to midline regions (4.4% ± 0.2% and 5.3% ± 0.2%, respectively). The largest mean strain for the proximal region was at the anterior layer (7.5% ± 1.1%) and that for the distal tendon region was at the posterior layer (7.9% ± 0.9%). This study shows significant regional differences in strain during ramped isometric contractions for the patellar tendon. Lower proximal strains in the posterior tendon compared to the anterior region may be associated with the suggestion of "stress shielding" as an etiological factor in insertional tendinopathy.

  18. Effects of microgravity and tail suspension on enzymes of individual soleus and tibialis anterior fibers

    NASA Technical Reports Server (NTRS)

    Chi, Maggie M.-Y.; Choski, Rati; Nemeth, Patti; Krasnov, Igor'; Il'ina-Kakueva, E. I.; Manchester, Jill K.; Lowry, Oliver H.

    1992-01-01

    Selected enzymes of energy metabolism were measured in random individual fibers of soleus and tibialis anterior (TA) muscles from rats exposed for 2 wk to spaceflight (F) aboard Cosmos 2044 or tail suspension (T) and from synchronous controls. Average size of soleus fibers (dry weight per unit length) was reduced 37 percent in F and T fibers; there was little change in Ta fibers. Enzyme changes were more pronounced in soleus than in TA fibers. Three enzymes characteristic of fast-twitch muscles, pyruvate kinase, glycerol-3-phosphate dehydrogenase, and 1-phosphofructokinase, were elevated in F and T soleus fibers, but changes in phosphofructokinase were not statistically significant. In TA fibers analyzed for hexokinase, malate dehydrogenase, phosphohexoisomerase, and pyruvate kinase, only hexokinase and malate dehydrogenase showed significant changes. Hexokinase incresed 83 percent in one of two T muscles. Enzyme data for TA fibers typed by myosin adenosinetriphosphatase were more informative: phosphofructokinase, phosphorylase, and glycerol-3-phosphate dehydrogenase were increased in type IIn fibers of either F or T muscles or both. Malate dehydrogenase was not changed in fibers of any type in either F or T muscle.

  19. Age-Associated Changes in the Spectral and Statistical Parameters of Surface Electromyogram of Tibialis Anterior

    PubMed Central

    2016-01-01

    Age-related neuromuscular change of Tibialis Anterior (TA) is a leading cause of muscle strength decline among the elderly. This study has established the baseline for age-associated changes in sEMG of TA at different levels of voluntary contraction. We have investigated the use of Gaussianity and maximal power of the power spectral density (PSD) as suitable features to identify age-associated changes in the surface electromyogram (sEMG). Eighteen younger (20–30 years) and 18 older (60–85 years) cohorts completed two trials of isometric dorsiflexion at four different force levels between 10% and 50% of the maximal voluntary contraction. Gaussianity and maximal power of the PSD of sEMG were determined. Results show a significant increase in sEMG's maximal power of the PSD and Gaussianity with increase in force for both cohorts. It was also observed that older cohorts had higher maximal power of the PSD and lower Gaussianity. These age-related differences observed in the PSD and Gaussianity could be due to motor unit remodelling. This can be useful for noninvasive tracking of age-associated neuromuscular changes. PMID:27610379

  20. Predictors for anterior pelvic tilt following surgical correction of flexed knee gait including patellar tendon shortening in children with cerebral palsy.

    PubMed

    Böhm, Harald; Hösl, Matthias; Döderlein, Leonhard

    2017-05-01

    Patellar tendon shortening procedure within single event multilevel surgeries was shown to improve crouch gait in Cerebral Palsy (CP) patients. However, one of the drawbacks associated to the correction of flexed knee gait may be increased pelvic anterior tilt with compensatory lumbar lordosis. Which CP patients are at risk for excessive anterior pelvic tilt following correction of flexed knee gait including patellar tendon shortening? 32 patients with CP between 8 and 18 years GMFCS I&II were included. They received patellar tendon shortenings within multilevel surgery. Patients with concomitant knee flexor lengthening were excluded. Gait analysis and clinical testing was performed pre- and 24.1 (SD=1.9) months postoperatively. Patients were subdivided into more/less than 5° increase in anterior pelvic tilt. Preoperative measures indicating m. rectus and m. psoas shortness, knee flexor over-length, hip extensor and abdominal muscle weakness and equinus gait were compared between groups. Stepwise multilinear regression of the response value increase in pelvic tilt during stance phase was performed from parameters that were significantly different between groups. 34% of patients showed more than 5° increased pelvic anterior tilt postoperatively. Best predictors for anterior pelvic tilt from preoperative measures were increased m. rectus tone and reduced hip extension during walking that explained together 39% of the variance in increase of anterior pelvic tilt. Every third patient showed considerable increased pelvic tilt following surgery of flexed knee gait. In particular patients with preoperative higher muscle tone in m. rectus and lower hip extension during walking were at risk and both features need to be addressed in the therapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Tendon Healing in Bone Tunnel after Human Anterior Cruciate Ligament Reconstruction: A Systematic Review of Histological Results.

    PubMed

    Lu, Hongbin; Chen, Can; Xie, Shanshan; Tang, Yifu; Qu, Jin

    2018-05-21

    Most studies concerning to tendon healing and incorporation into bone are mainly based on animal studies due to the invasive nature of the biopsy procedure. The evidence considering tendon graft healing to bone in humans is limited in several case series or case reports, and therefore, it is difficult to understand the healing process. A computerized search using relevant search terms was performed in the PubMed, EMBASE, Scopus, and Cochrane Library databases, as well as a manual search of reference lists. Searches were limited to studies that investigated tendon graft healing to bone by histologic examination after anterior cruciate ligament (ACL) reconstruction with hamstring. Ten studies were determined to be eligible for this systematic review. Thirty-seven cases were extracted from the included studies. Most studies showed that a fibrovascular interface would form at the tendon-bone interface at the early stage and a fibrous indirect interface with Sharpey-like fibers would be expected at the later stage. Cartilage-like tissue at tendon graft-bone interface was reported in three studies. Tendon graft failed to integrate with the surrounding bone in 10 of the 37 cases. Unexpectedly, suspensory type of fixation was used for the above failure cases. An indirect type of insertion with Sharpey-like fibers at tendon-bone interface could be expected after ACL reconstruction with hamstring. Regional cartilage-like tissue may form at tendon-bone interface occasionally. The underlying tendon-to-bone healing process is far from understood in the human hamstring ACL reconstruction. Further human studies are highly needed to understand tendon graft healing in bone tunnel after hamstring ACL reconstruction. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  2. Concordance of the location of the innervation zone of the tibialis anterior muscle using voluntary and imposed contractions by electrostimulation.

    PubMed

    Guzmán-Venegas, R A; Bralic, M P; Cordero, J J; Cavada, G; Araneda, O F

    2016-04-01

    The innervation zone (IZ) corresponds to the location of the neuromuscular junctions. Its location can be determined by using arranged surface linear electrode arrays. Typically, voluntary muscle contractions (VC) are used in this method. However, it also may be necessary to locate the IZ under clinical conditions such as spasticity, in which this type of contraction is difficult to perform. Therefore, contractions imposed by electrostimulation (ES) can be an alternative. There is little background comparing the locations of IZ obtained by two different types of contractions. Evaluate the concordance between using voluntary and imposed contractions from electrostimulation in order to determine the location of the innervation zone of the tibialis anterior muscle in healthy volunteers. The tibialis anterior (TA) muscle of sixteen volunteers (men: 8; women: 8; age: 22.1±1.4years, weight: 61.6±7.5kg, height: 167.1±7.5cm) were evaluated using a linear electrode array. The IZ of the TA muscle was located using two types of muscle contractions, voluntary (10% MVC) and imposed contractions by ES. The concordance between both conditions was evaluated using the Bland-Altman method and the concordance correlation coefficient (CCC). The analyses were applied to the absolute and relative positions to the length of an anatomical landmark frame. CCC for absolute position was 0.98 (p<0.0001, 95% CI [0.98-1.00], and CCC for relative positions also was 0.98 (p<0.0001, 95% CI [0.97-1.00]). The Bland-Altman analysis for absolute data showed an average difference of -0.63mm (SD: 4.1). Whereas, for adjusted data, the average difference was -0.20% (SD: 1.2). The power of the results, based on absolute data, was 98%, whereas for relative data, 82%. In healthy volunteers, there was a substantially concordance between the location of the IZ of the TA muscle derived from using contractions imposed by ES and the location derived from using VC. Copyright © 2016 Elsevier Ltd. All rights

  3. Electrical stimulation site influences the spatial distribution of motor units recruited in tibialis anterior.

    PubMed

    Okuma, Yoshino; Bergquist, Austin J; Hong, Mandy; Chan, K Ming; Collins, David F

    2013-11-01

    To compare the spatial distribution of motor units recruited in tibialis anterior (TA) when electrical stimulation is applied over the TA muscle belly versus the common peroneal nerve trunk. Electromyography (EMG) was recorded from the surface and from fine wires in superficial and deep regions of TA. Separate M-wave recruitment curves were constructed for muscle belly and nerve trunk stimulation. During muscle belly stimulation, significantly more current was required to generate M-waves that were 5% of the maximal M-wave (M max; M5%max), 50% M max (M 50%max) and 95% M max (M 95%max) at the deep versus the superficial recording site. In contrast, during nerve trunk stimulation, there were no differences in the current required to reach M5%max, M 50%max or M 95%max between deep and superficial recording sites. Surface EMG reflected activity in both superficial and deep muscle regions. Stimulation over the muscle belly recruited motor units from superficial to deep with increasing stimulation amplitude. Stimulation over the nerve trunk recruited superficial and deep motor units equally, regardless of stimulation amplitude. These results support the idea that where electrical stimulation is applied markedly affects how contractions are produced and have implications for the interpretation of surface EMG data. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  4. Do peak torque angles of muscles change following anterior cruciate ligament reconstruction using hamstring or patellar tendon graft?

    PubMed

    Yosmaoğlu, Hayri Baran; Baltacı, Gül; Sönmezer, Emel; Özer, Hamza; Doğan, Deha

    2017-12-01

    This study aims to compare the effects of anterior cruciate ligament (ACL) reconstruction using autogenous hamstring or patellar tendon graft on the peak torque angle. The study included 132 patients (103 males, 29 females; mean age 29±9 year) who were performed ACL reconstruction with autogenous hamstring or patellar tendon graft. The peak torque angles in the quadriceps and hamstring muscles were recorded using an isokinetic dynamometer. Angle of peak knee flexion torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the hamstring tendon group. Angle of peak knee extension torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the patellar tendon group. There were no statistically significant differences in the flexion and extension peak torque angles between the operated and nonoperated knees at 60°/second in both groups. The angle of peak torque at relatively high angular velocities is affected after ACL reconstruction in patients with hamstring or patellar tendon grafts. The graft donor site directly influences this parameter. This finding may be important for clinicians in terms of preventing re-injury.

  5. Subtle Lisfranc Injury: Low Energy Midfoot Sprain

    DTIC Science & Technology

    2007-09-01

    include the plantar fascia , the foot intrinsic muscles and tendons, and the insertions of the anterior tibialis, the posterior tibialis, and the...second additional avulsion fracture (Figure 1F, arrowhead) was noted adjacent to the plantar aspect of the base of the second metatarsal...fragment adjacent to the plantar surface of the base of the second metatarsal (white arrowhead). Discussion The tarsometatarsal articulation, also

  6. [Experimental study of tendon graft fixation in anterior cruciate ligament reconstruction with cortical press-fit bolt in rabbits].

    PubMed

    Qi, Wei; Li, Chun-bao; Wang, Jun-liang; Zhu, Juan-li; Liu, Yu-jie

    2013-05-21

    To explore the histological outcomes of tendon-bone healing in anterior cruciate ligament (ACL) reconstruction with cortical press-fit bolt (CPB). Twenty-four healthy female or male New Zealand White rabbits (2-3 months old) underwent bilateral ACL reconstruction with extensor digitorum longus tendon. A random method was used to decide one knee would receive the routine ACL reconstruction (control group) and another cortical press-fit bolt fixation (experimental group). After general anesthesia, extensor digitorum longus tendon was harvested and ACL reconstruction performed. All animals were sacrificed at 4, 8 and 12 weeks postoperation. Radiological and histological examinations were made at each timepoint. The specimens were stained with different methods to observe the pathological changes of tendon graft, bone tunnel and cortical press-fit bolt. More revascularization and massive new bone were found in tendon-bone junction of experimental group at 4, 8 and 12 weeks postoperation. The circum-graft new vessel proportion of the experimental and control groups were 0.48 ± 0.12 and 0.26 ± 0.05 respectively (P < 0.05). In the experimental group, more cartilage cells were present in tendon-bone junction at 12 weeks and the circum-graft new bone areas in two groups were 0.41 ± 0.11 and 0.21 ± 0.10 mm(2) respectively (P < 0.05). Cortical press-fit blot may improve tendon-bone healing after ACL reconstruction in rabbits. The application prospects of this procedure are promising.

  7. [Clinical application of peroneal muscles tendon transposition in repair of Achilles tendon rupture].

    PubMed

    Jin, Rihao; Jin, Yu; Fang, Xiulin

    2006-07-01

    To discuss applied anatomy, biomechanics and surgical procedures of long peroneal muscles tendon transposition in repair of occlusive achilles tendon rupture. The blood supply and the morphology of long peroneal muscles tendon were observed in the lower extremity of 50 sides adult specimens and the mechanical tests which stretch load on the tendon were carried out. The methods were designed on the basis of the anatomical characteristics and morphology. Ten patients suffering occlusive Achilles tendon rupture were treated by using long peroneal muscles tendon transposition from March 2001 to July 2004. Among 10 patients, there were 7 males and 3 females, aging 32 to 54 years including 6 cases of jump injury, 2 cases of bruise, 1 case of step vacancy and 1 case of spontaneity injury. The interval between injury and surgery was 6 hours to 7 days in 7 fresh rupture and 21 days to 3 months in 3 old rupture. All cases belonged to occlusive Achilles tendon rupture (8 cases of complete rupture and 2 cases of incomplete rupture). The origin of long peroneal muscles was proximal tibia and fibular head, the end of them was base of first metatarsal bones and medial cuboid. The length of tendon was 13.5 +/- 2.5 cm. The width of origin tendon was 0.9 +/- 0.2 cm and the thickness was 0.3 +/- 0.1 cm; the width on apex of lateral malleolus was 0.7 +/- 0.1 cm and the thickness was 0.4 +/- 0.1 cm, the width on head of cuboid was 0.7 +/- 0.1 cm and the thickness was 0.3 +/- 0.1 cm. The long peroneal muscles tendon had abundant blood supply. The results of mechanical test showed that the biggest load was 2,292.4 +/- 617.3 N on tendon calcaneus, 1,020.4 +/- 175.4 N on long peroneal muscles tendon, 752.0 +/- 165.4 N on peroneus brevis tendon and 938.2 +/- 216.7 N on tibialis posterior tendon. Ten cases of occlusive Achilles tendon rupture achieved healing by first intention and were followed up 18-24 months. No Achilles tendon re-rupture, necrosis of skin or other complications occurred

  8. Ultrasound definition of tendon damage in patients with rheumatoid arthritis. Results of a OMERACT consensus-based ultrasound score focussing on the diagnostic reliability.

    PubMed

    Bruyn, George A W; Hanova, Petra; Iagnocco, Annamaria; d'Agostino, Maria-Antonietta; Möller, Ingrid; Terslev, Lene; Backhaus, Marina; Balint, Peter V; Filippucci, Emilio; Baudoin, Paul; van Vugt, Richard; Pineda, Carlos; Wakefield, Richard; Garrido, Jesus; Pecha, Ondrej; Naredo, Esperanza

    2014-11-01

    To develop the first ultrasound scoring system of tendon damage in rheumatoid arthritis (RA) and assess its intraobserver and interobserver reliability. We conducted a Delphi study on ultrasound-defined tendon damage and ultrasound scoring system of tendon damage in RA among 35 international rheumatologists with experience in musculoskeletal ultrasound. Twelve patients with RA were included and assessed twice by 12 rheumatologists-sonographers. Ultrasound examination for tendon damage in B mode of five wrist extensor compartments (extensor carpi radialis brevis and longus; extensor pollicis longus; extensor digitorum communis; extensor digiti minimi; extensor carpi ulnaris) and one ankle tendon (tibialis posterior) was performed blindly, independently and bilaterally in each patient. Intraobserver and interobserver reliability were calculated by κ coefficients. A three-grade semiquantitative scoring system was agreed for scoring tendon damage in B mode. The mean intraobserver reliability for tendon damage scoring was excellent (κ value 0.91). The mean interobserver reliability assessment showed good κ values (κ value 0.75). The most reliable were the extensor digiti minimi, the extensor carpi ulnaris, and the tibialis posterior tendons. An ultrasound reference image atlas of tenosynovitis and tendon damage was also developed. Ultrasound is a reproducible tool for evaluating tendon damage in RA. This study strongly supports a new reliable ultrasound scoring system for tendon damage. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  9. A Comparative Animal Study of Tendon Grafts Healing After Remnant-Preserving Versus Conventional Anterior Cruciate Ligament Reconstruction

    PubMed Central

    Zhang, Lei; Jiang, Kan; Chai, Hao; Zhou, Mei; Bai, Jingping

    2016-01-01

    Background The aim of this study was to determine if anterior cruciate ligament (ACL) reconstruction by remnant preservation promotes cell proliferation, vascularization, proprioception recovery, and improved biomechanical properties of the tendon grafts. Material/Methods 75 New Zealand rabbits were randomly assigned into the control group (group A), conventional ACL reconstruction group (group B), ACL reconstruction using remnant preservation and graft through remnant sleeve technique group (group C), and ACL reconstruction using remnant preservation and remnant tensioning technique group (group D). The remnant and healing of tendon grafts in groups C and D were observed at 3, 6, and 12 weeks after surgery, and the mRNA expression levels of VEGF, NT-3 and GAP-43 in ACL (group A) or tendon graft samples (groups B, C, and D) were determined by real-time PCR. Tendon graft cell count, microvessel density (MVD), and proprioceptors were determined by H&E staining, CD34, and S-100 immunohistochemical staining. The biomechanical properties of the tendon graft at week 12 in groups B, C, and D were examined by using a tensile strength test. Results Remnant and tendon grafts were not healed at 3, 6, and 12 weeks after the operation in groups C and D. VEGF, NT-3, and GAP-43 mRNA expressions in groups B, C, and D were higher than those in group A (P<0.05), but no significant difference was observed between groups B, C, and D (P>0.05). Furthermore, tendon graft cell count, MVD, proprioception, and biomechanical properties showed no significant differences (P>0.05) among groups B, C, and D at various time points. Conclusions There was no significant difference in cell proliferation, vascularization, proprioception recovery, or biomechanical properties of the tendon grafts between remnant-preserving and conventional ACL reconstruction methods. PMID:27669454

  10. Acceleration of tendon-bone healing of anterior cruciate ligament graft using intermittent negative pressure in rabbits.

    PubMed

    Sun, Zhengming; Wang, Xiaoqing; Ling, Ming; Wang, Wei; Chang, Yanhai; Yang, Guang; Dong, Xianghui; Wu, Shixun; Wu, Xueyuan; Yang, Bo; Chen, Ming

    2017-04-18

    The purpose of this study was to test effects of negative pressure on tendon-bone healing after reconstruction of anterior cruciate ligament (ACL) in rabbits. Hind legs of 24 New Zealand White rabbits were randomly selected as negative pressure group and the contralateral hind legs as control. Reconstruction of the ACL was done. Joints of the negative pressure side were placed with drainage tubes connecting the micro-negative pressure aspirator. Control side was placed with ordinary drainage tubes. Drainage tubes on both sides were removed at the same time 5 days after operation. After 6 weeks, joint fluid was drawn to detect the expression levels of interleukin-1β (IL-1β) and tumor necrosis factor-α (TNF-α); at the same time, femur-ligament-tibia complex was obtained to determine tendon graft tension and to observe the histomorphology, blood vessels of the tendon-bone interface, and expression of vascular endothelial growth factor (VEGF). The maximum load breakage of tendon graft was significantly greater in the negative pressure group than in the control group (P < 0.05). Histological studies of the tendon-bone interface found that there was more new bone formation containing chondroid cells and aligned connective tissue in the negative pressure group than in the control group. Expression of VEGF was higher in the negative pressure group than in the control group (P < 0.01). Content of IL-1β and TNF-α in synovial fluid is lower in the negative pressure group than in the control group (P < 0.01). Intermittent negative pressure plays an active role in tendon-bone healing and creeping substitution of ACL reconstruction in the rabbits.

  11. Effects of Achilles tendon vibration, surface and visual conditions on lower leg electromyography in young adults with and without recurrent ankle sprains.

    PubMed

    Lubetzky, Anat V; Price, Robert; McCoy, Sarah W

    2016-07-01

    Functional ankle instability is associated with decreased ankle muscle function. Compliant surfaces and eyes-closed training are commonly used for rehabilitation and prevention of ankle sprains. Brief Achilles tendon vibration is commonly used in the study of postural control. To test the level of activation of tibialis anterior (TIB) and fibularis longus (FIB), bilateral Achilles tendon vibration was applied for the middle 20 s in a series of 60-s trials, when 10 healthy young adults and 10 adults with history of repeated ankle sprains were standing bipedal: on floor, on memory foam, or on a Both Sides Up (BOSU) ball, with eyes open, and on floor and foam with eyes closed. Differences in Integrated surface electromyography (IEMG) of TIB and FIB were significant for both groups pre, during, and post vibration (Friedman Tests, p < 0.001 for all). In both groups, the highest IEMG for TIB was obtained during vibration when standing on foam with eyes closed, whereas the highest IEMG for FIB was obtained during vibration when standing on the BOSU. Bipedal stance on BOSU and brief Achilles tendon vibration may be a useful intervention when a session's goal is to facilitate lower leg muscles activation. Future research should explore training effects as well as the effect of FIB tendon vibration. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Partial supraspinatus tears are associated with tendon lengthening.

    PubMed

    Farshad-Amacker, Nadja A; Buck, Florian M; Farshad, Mazda; Pfirrmann, Christian W A; Gerber, Christian

    2015-02-01

    Tendon tear may result in muscular retraction with the loss of contractile amplitude and strength of the rotator cuff muscles. Currently, neither a validated method of measuring supraspinatus tendon length nor normal values are known. It was therefore the purpose of this study to measure the normal length of the supraspinatus tendon and to determine whether partial tears are associated with changes in tendon length. MR examinations of 49 asymptomatic volunteers and 37 patients with arthroscopically proven, isolated partial tears of the supraspinatus tendon were compared. The ratio of the extramuscular tendon length to the distance between the footprint and the glenoid surface was calculated (TL/FG ratio). Tendon length measurements were taken by two independent readers at the bursal and articular surfaces at the anterior, the central and the posterior parts of the tendon. TL/FG ratios at the bursal surface of tendons with partial tears were significantly higher than those in the control group [anterior: 0.78 ± 0.20 vs. 0.66 ± 0.15 (p < 0.05); central: 0.61 ± 0.13 vs. 0.52 ± 0.10 (p < 0.05); posterior: 0.57 ± 0.15 vs. 0.52 ± 0.10 (p < 0.05)]. At the articular surface, differences were significant only anteriorly [0.60 ± 0.13, vs. 0.54 ± 0.10 (p < 0.05)]. A cut-off TL/FG ratio of 0.63 for measurements at the bursal surface in the center of the tendon achieved a sensitivity of 46 % and a specificity of 92 % for the identification of partial cuff tearing. A reproducible method for measurement of extramuscular supraspinatus tendon length is described. Partial tearing of the supraspinatus tendon is associated with significant tendon lengthening, suggesting failure in continuity, and this is most reliably measured on the bursal surface. III.

  13. Ultrasound in Total Hip Replacement: Value of Anterior Acetabular Cup Visibility and Contact With the Iliopsoas Tendon.

    PubMed

    Guillin, Raphaël; Bertaud, Valérie; Garetier, Marc; Fantino, Olivier; Polard, Jean-Louis; Lambotte, Jean-Christophe

    2018-06-01

    To assess visibility of the acetabular cup in total hip replacement and to determine the value of direct and indirect signs of iliopsoas impingement syndrome with ultrasound. Ultrasound examinations were performed by a single operator in 17 patients with iliopsoas impingement syndrome and 48 control patients. Cup visibility, contact between the cup and psoas tendon, and the presence of indirect signs of iliopsoas impingement syndrome were investigated in all patients. When the acetabular cup was visible, its size and position in relation to the psoas tendon were recorded. Anterior cup visibility (P = .03), contact with the psoas tendon (P < .001), psoas tendinopathy (P = .02), and iliopsoas bursitis (P < .001) were significantly associated with iliopsoas impingement syndrome, the latter reported with specificity of 100%. In the sagittal plane at the level of the psoas tendon, a maximum sagittal length of greater than 5 mm and a posteroanterior cup shift of 3 mm or greater yielded respective sensitivities of 82% and 59% and specificities of 81% and 100%. When iliopsoas impingement syndrome is clinically suspected, the presence of iliopsoas bursitis or a posteroanterior cup shift of greater than 3 mm under the psoas tendon serve to confirm the diagnosis. In the absence of these conditions, a therapeutic test may be necessary because of the incomplete, albeit high, specificity of other signs. © 2017 by the American Institute of Ultrasound in Medicine.

  14. Randomized Controlled Trial Comparing Orthosis Augmented by Either Stretching or Stretching and Strengthening for Stage II Tibialis Posterior Tendon Dysfunction.

    PubMed

    Houck, Jeff; Neville, Christopher; Tome, Josh; Flemister, Adolph

    2015-09-01

    The value of strengthening and stretching exercises combined with orthosis treatment in a home-based program has not been evaluated. The purpose of this study was to compare the effects of augmenting orthosis treatment with either stretching or a combination of stretching and strengthening in participants with stage II tibialis posterior tendon dysfunction (TPTD). Participants included 39 patients with stage II TPTD who were recruited from a medical center and then randomly assigned to a strengthening or stretching treatment group. Excluding 3 dropouts, there were 19 participants in the strengthening group and 17 in the stretching group. The stretching treatment consisted of a prefabricated orthosis used in conjunction with stretching exercises. The strengthening treatment consisted of a prefabricated orthosis used in conjunction with the stretching and strengthening exercises. The main outcome measures were self-report (ie, Foot Function Index and Short Musculoskeletal Function Assessment) and isometric deep posterior compartment strength. Two-way analysis of variance was used to test for differences between groups at 6 and 12 weeks after starting the exercise programs. Both groups significantly improved in pain and function over the 12-week trial period. The self-report measures showed minimal differences between the treatment groups. There were no differences in isometric deep posterior compartment strength. A moderate-intensity, home-based exercise program was minimally effective in augmenting orthosis wear alone in participants with stage II TPTD. Level I, prospective randomized study. © The Author(s) 2015.

  15. Convergence of flexor reflex and corticospinal inputs on tibialis anterior network in humans.

    PubMed

    Mackey, Ann S; Uttaro, Denise; McDonough, Maureen P; Krivis, Lisa I; Knikou, Maria

    2016-01-01

    Integration between descending and ascending inputs at supraspinal and spinal levels is a key characteristic of neural control of movement. In this study, we characterized convergence of the flexor reflex and corticospinal inputs on the tibialis anterior (TA) network in healthy human subjects. Specifically, we characterized the modulation profiles of the spinal TA flexor reflex following subthreshold and suprathreshold transcranial magnetic stimulation (TMS). We also characterized the modulation profiles of the TA motor evoked potentials (MEPs) following medial arch foot stimulation at sensory and above reflex threshold. TA flexor reflexes were evoked following stimulation of the medial arch of the foot with a 30 ms pulse train at innocuous intensities. TA MEPs were evoked following TMS of the leg motor cortex area. TMS at 0.7 and at 1.2 MEP resting threshold increased the TA flexor reflex when TMS was delivered 40-100 ms after foot stimulation, and decreased the TA flexor reflex when TMS was delivered 25-110 ms before foot stimulation. Foot stimulation at sensory and above flexor reflex threshold induced a similar time-dependent modulation in resting TA MEPs, that were facilitated when foot stimulation was delivered 40-100 ms before TMS. The flexor reflex and MEPs recorded from the medial hamstring muscle were modulated in a similar manner to that observed for the TA flexor reflex and MEP. Cutaneomuscular afferents from the distal foot can increase the output of the leg motor cortex area. Descending motor volleys that directly or indirectly depolarize flexor motoneurons increase the output of the spinal FRA interneuronal network. The parallel facilitation of flexor MEPs and flexor reflexes is likely cortical in origin. Afferent mediated facilitation of corticospinal excitability can be utilized to strengthen motor cortex output in neurological disorders. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All

  16. Changes in serum enzyme activities after injection of bupivacaine into rat tibialis anterior.

    PubMed

    Nosaka, K

    1996-08-01

    This study investigated the time course of changes in serum creatine kinase (CK), aspartate aminotransferase (AST), and alanine amino-transferase (ALT) activities after intramuscular injection of bupivacaine into the tibialis anterior (TA) of rats. Morphological changes in muscle cells, relationships between the amount of increase in the enzyme activities and the muscle mass damaged, and responses of serum enzymes to additional injections of bupivacaine hydrochloride (BPVC) were also examined. Adult male Wistar rats (24 wk) were placed into one of four groups. Group A (n = 7) was a control, and no injection was applied. Saline solution (0.5 ml of 0.9%) was injected into the right TA for group B (n = 5). BPVC (0.5 ml of 0.5%) was injected into the right TA for group C (n = 9) and into both the right and left TA for group D (n = 9). No increases in CK, AST, and ALT were observed for groups A and B. After BPVC injection, groups C and D showed significant (P < 0.01) increases in serum enzyme activities. CK peaked 4 h after BPVC injection, and AST and ALT peaked 12 h postinjection, then returned to the baseline by the time infiltration of mononuclear cells into the damaged muscle cells progressed. The amount of enzyme increase was significantly larger (P < 0.01) for group D compared with group C. Injection of BPVC into the right then into the left TA 4 h later displayed a bipolar response, and the second injection into the TA 12 wk after the first injection resulted in smaller increase in serum enzyme activities. It appeared that increases in serum enzyme activities reflected muscle damage; however, changes in enzymes occurred in the early stage of myonecrosis.

  17. Tendon and ligament injuries: the genetic component

    PubMed Central

    September, Alison V; Schwellnus, Martin P; Collins, Malcolm

    2007-01-01

    Tendons and ligaments within the upper and lower limbs are some of the more common sites of musculoskeletal injuries during physical activity. Several extrinsic and intrinsic factors have been shown to be associated with these injuries. More recently, studies have suggested that there is also, at least in part, a genetic component to the Achilles tendon, rotator cuff and anterior cruciate ligament injuries. However, specific genes have not been suggested to be associated with rotator cuff or anterior cruciate ligament injuries. Sequence variants of the tenascin C (TNC) gene, on the other hand, have been shown to be associated with Achilles tendinopathies and Achilles tendon ruptures, whereas a variant of the collagen V α 1 (COL5A1) gene has also been shown to be associated with Achilles tendinopathies. Both genes encode for important structural components of tendons and ligaments. The COL5A1 gene encodes for a component of type V collagen, which has an important role in regulating collagen fibre assembly and fibre diameters. The TNC gene, on the other hand, encodes for TNC, which regulates the tissue's response to mechanical load. To date, only variants in two genes have been shown to be associated with Achilles tendon injuries. In addition, although specific genes have not been identified, investigators have suggested that there is also a genetic component to both rotator cuff and anterior cruciate ligament injuries. In future, specific genotypes associated with increased risk of injury to specific tendons and ligaments can prevent these injuries by identifying individuals at higher risk. PMID:17261551

  18. A 45-year-old man presenting with anterior compartment syndrome three weeks following conservative treatment of an Achilles tendon rupture.

    PubMed

    van Niekerk, Michael; Jawad, Farrah; Huntley, James S; McCowan, Stuart

    2011-05-01

    Compartment syndrome complicating a ruptured Achilles tendon has previously been reported in a surgically treated patient. However--to our knowledge--this is the first report of compartment syndrome following conservative treatment. A 45-year-old man ruptured his Achilles tendon and elected to have treatment in an equinus cast. Three weeks later, he developed compartment syndrome and despite fasciotomy, required surgical debridement of his anterior compartment. Delay in both diagnosis and subsequent fasciotomy resulted in a poor outcome. Any suspicion of compartment syndrome mandates early compartmental pressure monitoring. The exact aetiology is uncertain but we speculate that the equinus position of his ankle combined with weight-bearing, was a major contributing factor.

  19. Inter-rater reliability of motor unit number estimates and quantitative motor unit analysis in the tibialis anterior muscle.

    PubMed

    Boe, S G; Dalton, B H; Harwood, B; Doherty, T J; Rice, C L

    2009-05-01

    To establish the inter-rater reliability of decomposition-based quantitative electromyography (DQEMG) derived motor unit number estimates (MUNEs) and quantitative motor unit (MU) analysis. Using DQEMG, two examiners independently obtained a sample of needle and surface-detected motor unit potentials (MUPs) from the tibialis anterior muscle from 10 subjects. Coupled with a maximal M wave, surface-detected MUPs were used to derive a MUNE for each subject and each examiner. Additionally, size-related parameters of the individual MUs were obtained following quantitative MUP analysis. Test-retest MUNE values were similar with high reliability observed between examiners (ICC=0.87). Additionally, MUNE variability from test-retest as quantified by a 95% confidence interval was relatively low (+/-28 MUs). Lastly, quantitative data pertaining to MU size, complexity and firing rate were similar between examiners. MUNEs and quantitative MU data can be obtained with high reliability by two independent examiners using DQEMG. Establishing the inter-rater reliability of MUNEs and quantitative MU analysis using DQEMG is central to the clinical applicability of the technique. In addition to assessing response to treatments over time, multiple clinicians may be involved in the longitudinal assessment of the MU pool of individuals with disorders of the central or peripheral nervous system.

  20. Soft-tissue allografts terminally sterilized with an electron beam are biomechanically equivalent to aseptic, nonsterilized tendons.

    PubMed

    Elenes, Egleide Y; Hunter, Shawn A

    2014-08-20

    Allograft safety is contingent on effective sterilization. However, current sterilization methods have been associated with decreased biomechanical strength and higher failure rates of soft-tissue allografts. In this study, electron beam (e-beam) sterilization was explored as an alternative sterilization method to preserve biomechanical integrity. We hypothesized that e-beam sterilization would not significantly alter the biomechanical properties of tendon allograft compared with aseptic, nonsterilized controls and gamma-irradiated grafts. Separate sets of forty fresh-frozen tibialis tendon allografts (four from each of ten donors) and forty bisected bone-patellar tendon-bone (BTB) allografts (four from each of ten donors) were randomly assigned to four study groups. One group received a 17.1 to 21.0-kGy gamma radiation dose; two other groups were sterilized with an e-beam at either a high (17.1 to 21.0-kGy) or low (9.2 to 12.2-kGy) dose. A fourth group served as nonsterilized controls. Each graft was cyclically loaded to 200 N of tension for 2000 cycles at a frequency of 2 Hz, allowed to relax for five minutes, and then tested in tension until failure at a 100%/sec strain rate. One-way analysis of variance testing was used to identify significant differences. Tibialis tendons sterilized with both e-beam treatments and with gamma irradiation exhibited values for cyclic tendon elongation, maximum load, maximum displacement, stiffness, maximum stress, maximum strain, and elastic modulus that were not significantly different from those of nonsterilized controls. BTB allografts sterilized with the high e-beam dose and with gamma irradiation were not significantly different in cyclic tendon elongation, maximum load, maximum displacement, stiffness, maximum stress, maximum strain, and elastic modulus from nonsterilized controls. BTB allografts sterilized with the e-beam at the lower dose were significantly less stiff than nonsterilized controls (p = 0.014) but did not

  1. Applications of In Vivo Functional Testing of the Rat Tibialis Anterior for Evaluating Tissue Engineered Skeletal Muscle Repair

    PubMed Central

    Mintz, Ellen L.; Passipieri, Juliana A.; Lovell, Daniel Y.; Christ, George J.

    2016-01-01

    Despite the regenerative capacity of skeletal muscle, permanent functional and/or cosmetic deficits (e.g., volumetric muscle loss (VML) resulting from traumatic injury, disease and various congenital, genetic and acquired conditions are quite common. Tissue engineering and regenerative medicine technologies have enormous potential to provide a therapeutic solution. However, utilization of biologically relevant animal models in combination with longitudinal assessments of pertinent functional measures are critical to the development of improved regenerative therapeutics for treatment of VML-like injuries. In that regard, a commercial muscle lever system can be used to measure length, tension, force and velocity parameters in skeletal muscle. We used this system, in conjunction with a high power, bi-phase stimulator, to measure in vivo force production in response to activation of the anterior crural compartment of the rat hindlimb. We have previously used this equipment to assess the functional impact of VML injury on the tibialis anterior (TA) muscle, as well as the extent of functional recovery following treatment of the injured TA muscle with our tissue engineered muscle repair (TEMR) technology. For such studies, the left foot of an anaesthetized rat is securely anchored to a footplate linked to a servomotor, and the common peroneal nerve is stimulated by two percutaneous needle electrodes to elicit muscle contraction and dorsiflexion of the foot. The peroneal nerve stimulation-induced muscle contraction is measured over a range of stimulation frequencies (1-200 Hz), to ensure an eventual plateau in force production that allows for an accurate determination of peak tetanic force. In addition to evaluation of the extent of VML injury as well as the degree of functional recovery following treatment, this methodology can be easily applied to study diverse aspects of muscle physiology and pathophysiology. Such an approach should assist with the more rational

  2. Applications of In Vivo Functional Testing of the Rat Tibialis Anterior for Evaluating Tissue Engineered Skeletal Muscle Repair.

    PubMed

    Mintz, Ellen L; Passipieri, Juliana A; Lovell, Daniel Y; Christ, George J

    2016-10-07

    Despite the regenerative capacity of skeletal muscle, permanent functional and/or cosmetic deficits (e.g., volumetric muscle loss (VML) resulting from traumatic injury, disease and various congenital, genetic and acquired conditions are quite common. Tissue engineering and regenerative medicine technologies have enormous potential to provide a therapeutic solution. However, utilization of biologically relevant animal models in combination with longitudinal assessments of pertinent functional measures are critical to the development of improved regenerative therapeutics for treatment of VML-like injuries. In that regard, a commercial muscle lever system can be used to measure length, tension, force and velocity parameters in skeletal muscle. We used this system, in conjunction with a high power, bi-phase stimulator, to measure in vivo force production in response to activation of the anterior crural compartment of the rat hindlimb. We have previously used this equipment to assess the functional impact of VML injury on the tibialis anterior (TA) muscle, as well as the extent of functional recovery following treatment of the injured TA muscle with our tissue engineered muscle repair (TEMR) technology. For such studies, the left foot of an anaesthetized rat is securely anchored to a footplate linked to a servomotor, and the common peroneal nerve is stimulated by two percutaneous needle electrodes to elicit muscle contraction and dorsiflexion of the foot. The peroneal nerve stimulation-induced muscle contraction is measured over a range of stimulation frequencies (1-200 Hz), to ensure an eventual plateau in force production that allows for an accurate determination of peak tetanic force. In addition to evaluation of the extent of VML injury as well as the degree of functional recovery following treatment, this methodology can be easily applied to study diverse aspects of muscle physiology and pathophysiology. Such an approach should assist with the more rational

  3. Reciprocal inhibition between motor neurons of the tibialis anterior and triceps surae in humans.

    PubMed

    Yavuz, Utku Ş; Negro, Francesco; Diedrichs, Robin; Farina, Dario

    2018-05-01

    Motor neurons innervating antagonist muscles receive reciprocal inhibitory afferent inputs to facilitate the joint movement in the two directions. The present study investigates the mutual transmission of reciprocal inhibitory afferent inputs between the tibialis anterior (TA) and triceps surae (soleus and medial gastrocnemius) motor units. We assessed this mutual mechanism in large populations of motor units for building a statistical distribution of the inhibition amplitudes during standardized input to the motor neuron pools to minimize the effect of modulatory pathways. Single motor unit activities were identified using high-density surface electromyography (HDsEMG) recorded from the TA, soleus (Sol), and medial gastrocnemius (GM) muscles during isometric dorsi- and plantarflexion. Reciprocal inhibition on the antagonist muscle was elicited by electrical stimulation of the tibial (TN) or common peroneal nerves (CPN). The probability density distributions of reflex strength for each muscle were estimated to examine the strength of mutual transmission of reciprocal inhibitory input. The results showed that the strength of reciprocal inhibition in the TA motor units was fourfold greater than for the GM and the Sol motor units. This suggests an asymmetric transmission of reciprocal inhibition between ankle extensor and flexor muscles. This asymmetry cannot be explained by differences in motor unit type composition between the investigated muscles since we sampled low-threshold motor units in all cases. Therefore, the differences observed for the strength of inhibition are presumably due to a differential reciprocal spindle afferent input and the relative contribution of nonreciprocal inhibitory pathways. NEW & NOTEWORTHY We investigated the mutual transmission of reciprocal inhibition in large samples of motor units using a standardized input (electrical stimulation) to the motor neurons. The results demonstrated that the disynaptic reciprocal inhibition exerted

  4. Irradiated Hamstring Tendon Allograft Versus Autograft for Anatomic Double-Bundle Anterior Cruciate Ligament Reconstruction: Midterm Clinical Outcomes.

    PubMed

    Tian, Shaoqi; Wang, Bin; Liu, Lun; Wang, Yuanhe; Ha, Chengzhi; Li, Qicai; Yang, Xu; Sun, Kang

    2016-10-01

    Most studies on grafts for anterior cruciate ligament (ACL) reconstruction (ACLR) have been of autografts or nonirradiated allografts with a single-bundle (SB) technique. Outcome reports evaluating anatomic double-bundle (DB) ACLR with a hamstring tendon autograft versus irradiated allograft are rare. To compare the clinical outcomes of arthroscopic anatomic DB ACLR with a hamstring tendon autograft versus irradiated allograft. Randomized controlled trial; Level of evidence, 2. Between 2008 and 2009, a total of 107 patients undergoing arthroscopic DB ACLR were prospectively randomized consecutively into 1 of 2 groups (autograft [Auto] group and irradiated allograft [Ir-Allo] group). All the surgical procedures were performed by the same senior surgeon using the DB reconstruction technique. All irradiated hamstring tendon allografts were sterilized with 2.5 Mrad of irradiation before distribution and were obtained from a single certified tissue bank. Graft fixation on the femoral side was by an Endobutton, and on the tibial side by a bioabsorbable interference screw augmented with a staple. The same rehabilitation protocol was applied to all patients. Before surgery and at a mean of 6.9 years of follow-up, patients were evaluated by the same observer according to objective and subjective clinical evaluations including detailed history, physical examination, radiography, functional knee ligament testing, KT-2000 arthrometer testing, Harner vertical jump and Daniel 1-legged hop tests, Lysholm score, Tegner score, International Knee Documentation Committee (IKDC) standard evaluation form, and Cincinnati knee score. A total of 83 patients (Auto: n = 40 [mean age, 29.2 ± 6.9 years]; Ir-Allo: n = 43 [mean age, 28.6 ± 7.2 years]) fulfilled follow-up and clinical evaluations. No significant differences were found between the 2 groups according to the overall IKDC functional and subjective evaluations as well as testing of activity levels. Significant between

  5. Three-Dimensional Bio-Printed Scaffold Sleeves With Mesenchymal Stem Cells for Enhancement of Tendon-to-Bone Healing in Anterior Cruciate Ligament Reconstruction Using Soft-Tissue Tendon Graft.

    PubMed

    Park, Sin Hyung; Choi, Yeong-Jin; Moon, Sang Won; Lee, Byung Hoon; Shim, Jin-Hyung; Cho, Dong-Woo; Wang, Joon Ho

    2018-01-01

    To investigate the efficacy of the insertion of 3-dimensional (3D) bio-printed scaffold sleeves seeded with mesenchymal stem cells (MSCs) to enhance osteointegration between the tendon and tunnel bone in anterior cruciate ligament (ACL) reconstruction in a rabbit model. Scaffold sleeves were fabricated by 3D bio-printing. Before ACL reconstruction, MSCs were seeded into the scaffold sleeves. ACL reconstruction with hamstring tendon was performed on both legs of 15 adult rabbits (aged 12 weeks). We implanted 15 bone tunnels with scaffold sleeves with MSCs and implanted another 15 bone tunnels with scaffold sleeves without MSCs before passing the graft. The specimens were harvested at 4, 8, and 12 weeks. H&E staining, immunohistochemical staining of type II collagen, and micro-computed tomography of the tunnel cross-sectional area were evaluated. Histologic assessment was conducted with a histologic scoring system. In the histologic assessment, a smooth bone-to-tendon transition through broad fibrocartilage formation was identified in the treatment group, and the interface zone showed abundant type II collagen production on immunohistochemical staining. Bone-tendon healing histologic scores were significantly higher in the treatment group than in the control group at all time points. Micro-computed tomography at 12 weeks showed smaller tibial (control, 9.4 ± 0.9 mm 2 ; treatment, 5.8 ± 2.9 mm 2 ; P = .044) and femoral (control, 9.6 ± 2.9 mm 2 ; treatment, 6.0 ± 1.0 mm 2 ; P = .03) bone-tunnel areas in the treated group than in the control group. The 3D bio-printed scaffold sleeve with MSCs exhibited excellent results in osteointegration enhancement between the tendon and tunnel bone in ACL reconstruction in a rabbit model. If secure biological healing between the tendon graft and tunnel bone can be induced in the early postoperative period, earlier, more successful rehabilitation may be facilitated. Three-dimensional bio-printed scaffold sleeves with

  6. [Influence of the posterior tibial tendon on the medial arch of the foot: an in vitro kinetic and kinematic study].

    PubMed

    Emmerich, J; Wülker, N; Hurschler, C

    2003-04-01

    The respective contributions of the active and passive structures of the foot to the stability of the medical arch were investigated using an in vitro kinetic and kinematic model. The effect of the tibialis posterior tendon on foot and ankle movements, and plantar pressure distribution of the foot were tested in a cadaveric human foot. The stance phase from heel-contact to toe-off of normal walking gait and after tibialis posterior tendon rupture was simulated in eight roentenographically normal human feet (age 66 +/- 19 years, males). Ground reaction force and tibial inclination was simulated by means of a tilting angle and force-controlled translation stage. Plantar pressure was measured using a pressure-measuring platform. The force developed by the flexors and extensor muscles of the foot were simulated via cables attached to 7 force-controlled hydraulic cylinders. Tibial rotation was produced by an electric servo-motor, and foot movements measured with an ultrasonic analysis system. The model was verified against the plantar distribution and kinematics of healthy subjects measured during normal gait. Tibialis posterior deficit did not result in any detectable changes in pressure or force-time integral in the medial regions of the foot--a common sign of flat foot (pressure: midfoot 0.2 < or = 0.9; medial forefoot 0.5 < or = p < or = 0.9; hallux 0.5 < or = p < or = 0.9; force-time integral: midfoot p = 0-871; medial forefoot p = 0.632; hallux p = 0.068). Only small tendential changes in the kinematics of the talus and calcaneus were observed in dorsiflexion (0-58 sec; talus 0.1 < or = p < or = 0.6; calcaneus 0.4 < or = p < or = 0.06) and eversion (talus: 0-60 sec. 0.1 < or = p < or = 0.6; calcaneus: 37-60 sec. 0.2 < or = p < or = 0.7). The results of this in vitro study show that defective tibialis posterior alone does not produce significant changes in the kinetics or kinematics of the stance phase of normal gait. This suggests that the development of flat foot

  7. [Tibial press-fit fixation of flexor tendons for reconstruction of the anterior cruciate ligament].

    PubMed

    Ettinger, M; Liodakis, E; Haasper, C; Hurschler, C; Breitmeier, D; Krettek, C; Jagodzinski, M

    2012-09-01

    Press-fit fixation of hamstring tendon autografts for anterior cruciate ligament reconstruction is an interesting technique because no hardware is necessary. This study compares the biomechanical properties of press-fit fixations to an interference screw fixation. Twenty-eight human cadaveric knees were used for hamstring tendon explantation. An additional bone block was harvested from the tibia. We used 28 porcine femora for graft fixation. Constructs were cyclically stretched and then loaded until failure. Maximum load to failure, stiffness and elongation during failure testing and cyclic loading were investigated. The maximum load to failure was 970±83 N for the press-fit tape fixation (T), 572±151 N for the bone bridge fixation (TS), 544±109 N for the interference screw fixation (I), 402±77 N for the press-fit suture fixation (S) and 290±74 N for the bone block fixation technique (F). The T fixation had a significantly better maximum load to failure compared to all other techniques (p<0.001). This study demonstrates that a tibial press-fit technique which uses an additional bone block has better maximum load to failure results compared to a simple interference screw fixation.

  8. Anterior cruciate ligament (ACL) autograft reconstruction with hamstring tendons: clinical research among three rehabilitation procedures.

    PubMed

    Zhu, Weimin; Wang, Daping; Han, Yun; Zhang, Na; Zeng, Yanjun

    2013-12-01

    To compare the effects of the three rehabilitation procedures following anterior cruciate ligament (ACL) autograft reconstruction with hamstring tendons. An observational and retrospective case-controlled series. The Department of Sports Medicine, Shenzhen Second People Hospital, Shenzhen, PR China. Forty-five patients who were made to undergo ACL reconstructions by using quadrupled semitendinosus and gracilis tendons were divided into three groups: accelerated rehabilitation procedures group, aggressive rehabilitation procedures group, and self-made rehabilitation procedures group. The knee range of motion, thigh perimeter, IKDC score, and bone tunnel diameter in 3D-CT films were evaluated 3 and 6 months and 1 year later. The knee range of motion and thigh perimeter of group A were higher than those of group B and group C at 3, 6, and 12 months. IKDC scores of group C were better than those of groups A and B. The bone tunnel widening with group B was larger than that with groups A and C, and the differences were statistically significant (P < 0.05). Early rehabilitation is beneficial for restoration of knee function after ACL reconstruction. Moderate procedure is better than accelerated procedure.

  9. Isokinetic evaluation of internal/external tibial rotation strength after the use of hamstring tendons for anterior cruciate ligament reconstruction.

    PubMed

    Armour, Tanya; Forwell, Lorie; Litchfield, Robert; Kirkley, Alexandra; Amendola, Ned; Fowler, Peter J

    2004-01-01

    Evaluation of the knee after an anterior cruciate ligament reconstruction with the use of the semitendinosus and gracilis (hamstring) autografts has primarily focused on flexion and extension strength. The semitendinosus and gracilis muscles contribute to internal tibial rotation, and it has been suggested that harvest of these tendons for the purpose of an anterior cruciate ligament reconstruction contributes to internal tibial rotation weakness. Internal tibial rotation strength may be affected by the semitendinosus and gracilis harvest after anterior cruciate ligament reconstruction. Prospective evaluation of internal and external tibial rotation strength. Inclusion criteria for subjects (N = 30): unilateral anterior cruciate ligament reconstruction at least 2 years previously, a stable anterior cruciate ligament (<5-mm side-to-side difference) at time of testing confirmed by surgeon and KT-1000 arthrometer, no history of knee problems after initial knee reconstruction, a normal contralateral knee, and the ability to comply with the testing protocol. In an attempt to minimize unwanted subtalar joint motion, subjects were immobilized using an ankle brace and tested at angular velocities of 60 degrees /s, 120 degrees /s, and 180 degrees /s at a knee flexion angle of 90 degrees . The mean peak torque measurements for internal rotation strength of the operative limb (60 degrees /s, 17.4 +/- 4.5 ft-lb; 120 degrees /s, 13.9 +/- 3.3 ft-lb; 180 degrees /s, 11.6 +/- 3.0 ft-lb) were statistically different compared to the nonoperated limb (60 degrees /s, 20.5 +/- 4.7 ft-lb; 120 degrees /s, 15.9 +/- 3.8 ft-lb; 180 degrees /s, 13.4 +/- 3.8 ft-lb) at 60 degrees /s (P = .012), 120 degrees /s (P = .036), and 180 degrees /s (P = .045). The nonoperative limb demonstrated greater strength at all speeds. The mean torque measurements for external rotation were statistically similar when compared to the nonoperated limb at all angular velocities. We have shown through our study that

  10. The Achilles Tendon Insertion is Crescent-shaped: An In Vitro Anatomic Investigation

    PubMed Central

    Arentz, Sabine; Nauck, Tanja; Dorn-Lange, Nadja V.; Konerding, Moritz A.

    2008-01-01

    Anatomic and operative textbooks and current literature do not clearly describe the Achilles tendon interface to the calcaneal tuberosity. We dissected 51 specimens to identify the detailed anatomy of the Achilles tendon insertion. Achilles tendon fascicles expanded from the anterior aspect of the distal Achilles tendon over the retrocalcaneal bursa to the anterior part of the Haglund’s tuberosity in nearly half of the specimens. The insertion of the transverse section of the Achilles tendon regularly had a crescent-shape corresponding to the posterior calcaneal prominence. In transverse sections, all specimens had a curved appearance with a radius of curvature ranging from 13.8 mm to 43.6 mm (mean, 20.4 mm) and Achilles tendon extensions to the lateral and medial calcaneal surfaces reached 1.0 mm (mean) and 3.5 mm (mean) anterior in relation to the most posterior point of the calcaneal tuberosity. Knowledge of the arcuate configuration and of the medial and lateral extensions of the plantaris and the Achilles tendon insertion with respect to the transverse plane is important to avoid iatrogenic complications during resection of Haglund’s tuberosity. PMID:18506561

  11. Autograft versus nonirradiated allograft tissue for anterior cruciate ligament reconstruction: a systematic review.

    PubMed

    Mariscalco, Michael W; Magnussen, Robert A; Mehta, Divyesh; Hewett, Timothy E; Flanigan, David C; Kaeding, Christopher C

    2014-02-01

    An autograft has traditionally been the gold standard for anterior cruciate ligament reconstruction (ACLR), but the use of allograft tissue has increased in recent years. While numerous studies have demonstrated that irradiated allografts are associated with increased failure rates, some report excellent results after ACLR with nonirradiated allografts. The purpose of this systematic review was to determine whether the use of nonirradiated allograft tissue is associated with poorer outcomes when compared with autografts. Patients undergoing ACLR with autografts versus nonirradiated allografts will demonstrate no significant differences in graft failure risk, laxity on postoperative physical examination, or differences in patient-oriented outcome scores. Systematic review. A systematic review was performed to identify prospective or retrospective comparative studies (evidence level 1, 2, or 3) of autografts versus nonirradiated allografts for ACLR. Outcome data included graft failure based on clinical findings and instrumented laxity, postoperative laxity on physical examination, and patient-reported outcome scores. Studies were excluded if they did not specify whether the allograft had been irradiated. Quality assessment and data extraction were performed by 2 examiners. Nine studies comparing autografts and nonirradiated allografts were included. Six of the 9 studies compared bone-patellar tendon-bone (BPTB) autografts with BPTB allografts. Two studies compared hamstring tendon autografts to hamstring tendon allografts, and 1 study compared hamstring tendon autografts to tibialis anterior allografts. The mean patient age in 7 of 9 studies ranged from 24.5 to 32 years, with 1 study including only patients older than 40 years and another not reporting patient age. The mean follow-up duration was 24 to 94 months. Six of 9 studies reported clinical graft failure rates, 8 of 9 reported postoperative instrumented laxity measurements, 7 of 9 reported postoperative

  12. Inducement of semitendinosus tendon regeneration to the pes anserinus after its harvest for anterior cruciate ligament reconstruction-A new inducer grafting technique

    PubMed Central

    2012-01-01

    Purpose To investigate the usefulness of the “inducer grafting” technique for regeneration of the semitendinosus (ST) tendon after its harvest for anterior cruciate ligament (ACL) reconstruction. Methods Twenty knees of 20 patients (mean age at the time of surgery, 23.1 years) underwent ACL reconstruction with a double bundle autograft using the ST tendon (7 patients) and the ST + the gracilis (G) tendons (13 patients). “Inducer grafting” technique After harvesting the ST tendon, a passing pin with a loop thread is inserted along with the tendon stripper. The passing pin is pulled out from the medial thigh and the loop thread retained. As an inducer graft, the ST tendon branch is used. After the ACL graft has been secured, the inducer graft is sutured to the pes anserinus and the proximal end passed through by pulling the thread out. Then the inducer graft is placed within the tendon canal. The mean follow-up period was 15 months. The presence and morphology of the regenerated ST tendon were examined by MRI. And the isometric hamstring strength was examined at 45°, 90° and 120° of knee flexion. Results One month after the operation in all the patients, MRI demonstrated a low-intensity structure at the anatomical location of the ST, at the level of the superior pole of the patella and the joint line, apparently representing the regenerated ST tendon. Four months after the operation, the distal portion of the regenerated ST tendon had reached the pes anserinus in all patients. Twelve months after the operation, the regenerated ST tendon was hypertrophic in 19 of the 20 patients (95%). The isometric knee flexion torque of the ACL-reconstructed limb was significantly lower at 90° and 120° compared with the contralateral limb. Conclusion These results suggest that the “inducer grafting” technique is able to improve the regeneration rate of the harvested ST tendon and promote hypertrophy of the regenerated ST tendon, extending all the way to the pes

  13. Anatomic single-bundle anterior cruciate ligament reconstruction improves walking economy: hamstrings tendon versus patellar tendon grafts.

    PubMed

    Iliopoulos, Efthymios; Galanis, Nikiforos; Zafeiridis, Andreas; Iosifidis, Michael; Papadopoulos, Pericles; Potoupnis, Michael; Geladas, Nikolaos; Vrabas, Ioannis S; Kirkos, John

    2017-10-01

    Anterior cruciate ligament (ACL) injury is associated with a pathologic gait pattern and increased energy cost during locomotion. ACL reconstruction could improve the gait pattern. Hamstrings tendon (HAM) and bone-patellar tendon-bone (BPTB) grafts are usually used for reconstruction. The aim of this study was to compare the efficacy of anatomic ACL reconstruction with HAM and BPTB grafts on improving and normalizing the energy cost and physiologic reserves during flat, uphill, and downhill walking. Twenty male subjects with unilateral ACL injuries were randomly assigned to ACL reconstruction with a HAM (n = 10) or BPTB (n = 10) graft. Ten matched controls were also enrolled. All participants performed three 8-min walking tasks at 0, +10, and -10 % gradients before and 9 months after surgery. Energy cost (oxygen consumption, VO 2 ), heart rate (HR), and ventilation (VE) were measured. Lysholm/IKDC scores were recorded. Pre-operatively, VO 2 , HR, and VE were higher in the HAM and BPTB groups than in controls during walking at 0, +10, and -10 % gradients (p < 0.001-0.01). Post-operatively, both HAM and BPTB groups showed reduced VO 2 , HR, and VE during the three walking tasks (p < 0.001-0.01). Although the post-operative VO 2 in both surgical groups reached 90-95 % of the normative (control) value during walking, it remained elevated against the value observed in controls (p < 0.001-0.01). The HAM and BPTB groups showed no differences in post-surgical VO 2 or HR during walking at all three gradients. Anatomic ACL reconstruction with either HAM or BPTB graft resulted in similar short-term improvements in energy cost and nearly normalized locomotion economy and cardiorespiratory reserves during flat, uphill, and downhill walking. The improved locomotion economy is an additional benefit of anatomic ACL reconstruction, irrespective of the type of graft used, that the orthopaedic surgeons should consider. II.

  14. Anatomic Double-Bundle Anterior Cruciate Ligament Reconstruction With a Free Quadriceps Tendon Autograft.

    PubMed

    Caterev, Sergiu; Nistor, Dan Viorel; Todor, Adrian

    2016-10-01

    Anatomic double-bundle anterior cruciate ligament (ACL) reconstruction aims to restore the 2 functional bundles of the ACL in an attempt to better reproduce the native biomechanics of the injured knee and promote long-term knee health. However, this concept is not fully accepted and is not performed on a standard basis. In addition, the superiority of this technique over the conventional single-bundle technique has been questioned, especially the long-term clinical results. One of the down sides of the double-bundle reconstruction is the complexity of the procedure, with increased risks, operative time, and costs compared with the single-bundle procedure. Also, the revision procedure, if necessary, is more challenging. We propose a technique that has some advantages over the traditional double-bundle procedure, using a single femoral tunnel, 2 tibial tunnels, and a free quadriceps tendon autograft.

  15. Local infiltration analgesia is comparable to femoral nerve block after anterior cruciate ligament reconstruction with hamstring tendon graft: a randomised controlled trial.

    PubMed

    Kristensen, Pia Kjær; Pfeiffer-Jensen, Mogens; Storm, Jens Ole; Thillemann, Theis Muncholm

    2014-02-01

    Arthroscopic anterior cruciate ligament (ACL) reconstruction is a painful procedure requiring intensive postoperative pain management. Femoral nerve block is widely used in ACL surgery. However, femoral nerve block does not cover the donor site of the hamstring tendons. Local infiltration analgesia is a simple technique that has proven effective in postoperative pain management after total knee arthroplasty. Further, local infiltration analgesia covers the donor site and is associated with few complications. It was hypothesised that local infiltration analgesia at the donor site and wounds would decrease pain and opioid consumption after ACL reconstruction with hamstring tendon graft. Sixty patients undergoing primary ACL surgery with hamstring tendon graft were randomised to receive either local infiltration analgesia or femoral nerve block. Pain was scored on the numeric rating scale, and use of opioid, range of motion and adverse effects were assessed at the postoperative recovery unit (0 h), 3, 24 and 48 h, postoperatively. There were no significant differences between the groups in pain intensity or total opioid consumption at any of the follow-up points. Further, there were no differences between groups concerning side effects and range of motion. Local infiltration analgesia and femoral nerve block are similar in the management of postoperative pain after ACL reconstruction with hamstring tendon graft. Until randomised studies have investigated femoral nerve block combined with infiltration at the donor site, we recommend local infiltration analgesia in ACL reconstruction with hamstring tendon graft.

  16. Arthroscopic single-bundle anterior cruciate ligament reconstruction with six-strand hamstring tendon allograft versus bone-patellar tendon-bone allograft.

    PubMed

    Dai, Chengliang; Wang, Fei; Wang, Xiaomeng; Wang, Ruipeng; Wang, Shengjie; Tang, Shiyu

    2016-09-01

    The aim of this study was to compare the clinical outcomes of arthroscopic single-bundle anterior cruciate ligament (ACL) reconstruction with six-strand hamstring tendon (HT) allograft versus bone-patellar tendon-bone (BPTB) allograft. The prospective randomized controlled trial was included 129 patients. Sixty-nine patients received reconstruction with six-strand HT allografts (HT group), whereas 60 patients with BPTB allografts (BPTB group). Outcome assessment included re-rupture findings, International Knee Documentation Committee (IKDC) scores, Lysholm scores, KT-1000 arthrometer, Lachman test, pivot-shift test, range of motion (ROM) and single-leg hop test. At a mean follow-up of 52 months, 113 patients (HT group, 61 patients; BPTB group, 52 patients) completed a minimum 4-year follow-up. Four patients in HT group and six in BPTB group experienced ACL re-rupture (6.2 vs. 10.3 %) and received revision surgery. Significant between-group differences were observed in KT-1000 outcomes and pivot-shift test 1 (1.2 ± 1.5 vs. 1.8 ± 1.3, p = 0.025; positive rate 6.5 vs. 18.9 %, p = 0.036), 2 (1.1 ± 1.4 vs. 1.6 ± 1.2, p = 0.044; 8.1 vs. 20.7 %, p = 0.039), 4 (1.1 ± 1.5 vs. 1.7 ± 1.4, p = 0.031; 9.7 vs. 25 %, p = 0.012) years postoperatively. The outcomes between the two groups were comparable in terms of IKDC scores, Lysholm scores, Lachman test, ROM and single-leg hop test. Six-strand HT allograft achieved superior anteroposterior and rotational stability after single-bundle ACL reconstruction. It is a reasonable graft substitute for ACL reconstruction. II.

  17. EMG analysis of peroneal and tibialis anterior muscle activity prior to foot contact during functional activities.

    PubMed

    McLoda, T A; Hansen, A J; Birrer, D A

    2004-06-01

    The purpose of this investigation was to determine the pre-activity of the tibialis anterior (TA), peroneus longus (PL), and peroneus brevis (PB) prior to foot contact during three conditions. Twenty-six subjects (age 22 +/- 2 yrs; 15 male, 11 female) with no lower extremity injuries reported for data collection. Data were collected from each subject's dominant leg using surface electromyography (EMG). EMG electrodes were applied over the test muscles using a standard protocol. A heel-toe strike transducer was affixed to the bottom of the subject's shoe. The subject completed two randomized trials of walking on a treadmill (5.6 kph), jogging on a treadmill (9.3 kph) and drop landing from a 38 cm box. Isometric reference positions (IRPs) were recorded for the TA, PL, and PB. Muscle data were normalized to IRPs and the average processed EMG for the 200 ms prior to heel strike during walking and jogging and prior to toe strike when dropping from the box was used for analysis. A one-way repeated measures MANOVA was used to detect differences in pre-activity of the muscles between the three conditions. Univariate tests were used to determine differences for each muscle and Tukey's was applied post hoc to determine individual effect differences. The MANOVA revealed significant differences among the three conditions (F2.50 = 10.770; P < .0005). Average TA activity was significantly higher during jogging (Tukey's; P < .0005). Significant differences existed between each condition for the TA. Average PL and PB activity was significantly higher when drop landing (Tukey's; P < .0005). There was no significant difference between walking and jogging for the PL and PB. The amount of muscle pre-activity occurring before heel or toe strike provides useful information for the examination of reaction times to unexpected inversion during dynamic activities.

  18. Effect of low dose and moderate dose gamma irradiation on the mechanical properties of bone and soft tissue allografts.

    PubMed

    Balsly, Colleen R; Cotter, Andrew T; Williams, Lisa A; Gaskins, Barton D; Moore, Mark A; Wolfinbarger, Lloyd

    2008-12-01

    The increased use of allograft tissue for musculoskeletal repair has brought more focus to the safety of allogenic tissue and the efficacy of various sterilization techniques. Gamma irradiation is an effective method for providing terminal sterilization to biological tissue, but it is also reported to have deleterious effects on tissue mechanics in a dose-dependent manner. At irradiation ranges up to 25 kGy, a clear relationship between mechanical strength and dose has yet to be established. The aim of this study was to investigate the mechanical properties of bone and soft tissue allografts, irradiated on dry ice at a low absorbed dose (18.3-21.8 kGy) and a moderate absorbed dose (24.0-28.5 kGy), using conventional compressive and tensile testing, respectively. Bone grafts consisted of Cloward dowels and iliac crest wedges, while soft tissue grafts consisted of patellar tendons, anterior tibialis tendons, semitendinosus tendons, and fascia lata. There were no statistical differences in mechanical strength or modulus of elasticity for any graft irradiated at a low absorbed dose, compared to control groups. Also, bone allografts and two soft tissue allografts (anterior tibialis and semitendinosus tendon) that were irradiated at a moderate dose demonstrated similar strength and modulus of elasticity values to control groups. The results of this study support the use of low dose and moderate dose gamma irradiation of bone grafts. For soft tissue grafts, the results support the use of low dose irradiation.

  19. THE ROLE OF MECHANOBIOLOGY IN TENDON HEALING

    PubMed Central

    Killian, Megan L.; Cavinatto, Leonardo; Galatz, Leesa M.; Thomopoulos, Stavros

    2011-01-01

    Mechanical cues affect tendon healing, homeostasis, and development in a variety of settings. Alterations in the mechanical environment are known to result in changes in the expression of extracellular matrix proteins, growth factors, transcription factors, and cytokines that can alter tendon structure and cell viability. Loss of muscle force in utero or in the immediate postnatal period delays tendon and enthesis development. The response of healing tendons to mechanical load varies depending on anatomic location. Flexor tendons require motion to prevent adhesion formation, yet excessive force results in gap formation and subsequent weakening of the repair. Excessive motion in the setting of anterior cruciate ligament reconstruction causes accumulation of macrophages, which are detrimental to tendon graft healing. Complete removal of load is detrimental to rotator cuff healing, yet large forces are also harmful. Controlled loading can enhance healing in most settings; however, a fine balance must be reached between loads that are too low (leading to a catabolic state) and too high (leading to micro-damage). This review will summarize existing knowledge of the mechanobiology of tendon development, homeostasis, and healing. PMID:22244066

  20. Morphological and molecular comparisons between tibialis anterior muscle and levator veli palatini muscle: A preliminary study on their augmentation potential.

    PubMed

    Cheng, Xu; Song, Lei; Lan, Min; Shi, Bing; Li, Jingtao

    2018-01-01

    Tibialis anterior (TA) muscle and other somite-derived limb muscles remain the prototype in skeletal muscle study. The majority of head muscles, however, develop from branchial arches and maintain a number of heterogeneities in comparison with their limb counterparts. Levator veli palatini (LVP) muscle is a deep-located head muscle responsible for breathing, swallowing and speech, and is central to cleft palate surgery, yet lacks morphological and molecular investigation. In the present study, multiscale in vivo analyses were performed to compare TA and LVP muscle in terms of their myofiber composition, in-situ stem cell population and augmentation potential. TA muscle was identified to be primarily composed of type 2B myofibers while LVP muscle primarily consisted of type 2A and 2X myofibers. In addition, LVP muscle maintained a higher percentage of centrally-nucleated myofibers and a greater population of satellite cells. Notably, TA and LVP muscle responded to exogenous Wnt7a stimulus in different ways. Three weeks after Wnt7a administration, TA muscle exhibited an increase in myofiber number and a decrease in myofiber size, while LVP muscle demonstrated no significant changes in myofiber number or myofiber size. These results suggested that LVP muscle exhibits obvious differences in comparison with TA muscle. Therefore, knowledge acquired from TA muscle studies requires further testing before being applied to LVP muscle.

  1. Changes in Muscle Cell Metabolism and Mechanotransduction Are Associated with Myopathic Phenotype in a Mouse Model of Collagen VI Deficiency

    PubMed Central

    De Palma, Sara; Leone, Roberta; Grumati, Paolo; Vasso, Michele; Polishchuk, Roman; Capitanio, Daniele; Braghetta, Paola; Bernardi, Paolo; Bonaldo, Paolo; Gelfi, Cecilia

    2013-01-01

    This study identifies metabolic and protein phenotypic alterations in gastrocnemius, tibialis anterior and diaphragm muscles of Col6a1−/− mice, a model of human collagen VI myopathies. All three muscles of Col6a1−/− mice show some common changes in proteins involved in metabolism, resulting in decreased glycolysis and in changes of the TCA cycle fluxes. These changes lead to a different fate of α-ketoglutarate, with production of anabolic substrates in gastrocnemius and tibialis anterior, and with lipotoxicity in diaphragm. The metabolic changes are associated with changes of proteins involved in mechanotransduction at the myotendineous junction/costameric/sarcomeric level (TN-C, FAK, ROCK1, troponin I fast) and in energy metabolism (aldolase, enolase 3, triose phosphate isomerase, creatine kinase, adenylate kinase 1, parvalbumin, IDH1 and FASN). Together, these change may explain Ca2+ deregulation, impaired force development, increased muscle-relaxation-time and fiber damage found in the mouse model as well as in patients. The severity of these changes differs in the three muscles (gastrocnemius<tibialis anteriortendon (myotendineous junction) ratio and to muscle morphology. PMID:23437220

  2. Changes in muscle cell metabolism and mechanotransduction are associated with myopathic phenotype in a mouse model of collagen VI deficiency.

    PubMed

    De Palma, Sara; Leone, Roberta; Grumati, Paolo; Vasso, Michele; Polishchuk, Roman; Capitanio, Daniele; Braghetta, Paola; Bernardi, Paolo; Bonaldo, Paolo; Gelfi, Cecilia

    2013-01-01

    This study identifies metabolic and protein phenotypic alterations in gastrocnemius, tibialis anterior and diaphragm muscles of Col6a1(-/-) mice, a model of human collagen VI myopathies. All three muscles of Col6a1(-/-) mice show some common changes in proteins involved in metabolism, resulting in decreased glycolysis and in changes of the TCA cycle fluxes. These changes lead to a different fate of α-ketoglutarate, with production of anabolic substrates in gastrocnemius and tibialis anterior, and with lipotoxicity in diaphragm. The metabolic changes are associated with changes of proteins involved in mechanotransduction at the myotendineous junction/costameric/sarcomeric level (TN-C, FAK, ROCK1, troponin I fast) and in energy metabolism (aldolase, enolase 3, triose phosphate isomerase, creatine kinase, adenylate kinase 1, parvalbumin, IDH1 and FASN). Together, these change may explain Ca(2+) deregulation, impaired force development, increased muscle-relaxation-time and fiber damage found in the mouse model as well as in patients. The severity of these changes differs in the three muscles (gastrocnemius<tibialis anteriortendon (myotendineous junction) ratio and to muscle morphology.

  3. Full-thickness tears of the supraspinatus tendon: A three-dimensional finite element analysis.

    PubMed

    Quental, C; Folgado, J; Monteiro, J; Sarmento, M

    2016-12-08

    Knowledge regarding the likelihood of propagation of supraspinatus tears is important to allow an early identification of patients for whom a conservative treatment is more likely to fail, and consequently, to improve their clinical outcome. The aim of this study was to investigate the potential for propagation of posterior, central, and anterior full-thickness tears of different sizes using the finite element method. A three-dimensional finite element model of the supraspinatus tendon was generated from the Visible Human Project data. The mechanical behaviour of the tendon was fitted from experimental data using a transversely isotropic hyperelastic constitutive model. The full-thickness tears were simulated at the supraspinatus tendon insertion by decreasing the interface area. Tear sizes from 10% to 90%, in 10% increments, of the anteroposterior length of the supraspinatus footprint were considered in the posterior, central, and anterior regions of the tendon. For each tear, three finite element analyses were performed for a supraspinatus force of 100N, 200N, and 400N. Considering a correlation between tendon strain and the risk of tear propagation, the simulated tears were compared qualitatively and quantitatively by evaluating the volume of tendon for which a maximum strain criterion was not satisfied. The finite element analyses showed a significant impact of tear size and location not only on the magnitude, but also on the patterns of the maximum principal strains. The mechanical outcome of the anterior full-thickness tears was consistently, and significantly, more severe than that of the central or posterior full-thickness tears, which suggests that the anterior tears are at greater risk of propagating than the central or posterior tears. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Surgical treatment for partial rupture of the distal biceps tendon using palmaris longus tendon graft: A case report.

    PubMed

    Ozasa, Yasuhiro; Wada, Takuro; Iba, Kousuke; Yamashita, Toshihiko

    2018-03-08

    We report a case of a partial rupture of the distal biceps tendon that was surgically treated using a palmaris longus tendon graft. A 58-year-old man complained of increasing pain with resisted elbow flexion and supination in the antecubital fossa. Magnetic resonance imaging revealed the irregularity of a distal attachment of the biceps brachii and peripheral signal changes. We diagnosed a partial rupture of the distal biceps tendon. Because conservative treatment failed, surgical treatment was performed through a single anterior approach. The insertion of the tendon was partially ruptured at the radial tuberosity. After the involved site was debrided, the palmaris longus tendon was grafted with suture anchors to reinforce the remaining tendon. Postoperative immobilization was not performed, and all moves were freed after 3 weeks. At the 6-year postoperative follow-up, the patient no longer experienced pain and returned to his original job without any limitations. Copyright © 2018 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  5. Visualization of the extra-articular portion of the long head of the biceps tendon during intra-articular shoulder arthroscopy.

    PubMed

    Festa, Anthony; Allert, Jesse; Issa, Kimona; Tasto, James P; Myer, Jonathan J

    2014-11-01

    To quantify the amount of the extra-articular long head of the biceps tendon (LHBT) seen during intra-articular shoulder arthroscopy by pulling the tendon into the joint with a probe through an anterior portal while viewing through a standard posterior portal. Intra-articular shoulder arthroscopy was performed on 10 forequarter cadaveric specimens. The extra-articular portion of the LHBT was evaluated by pulling the tendon into the joint with an arthroscopic probe inserted through an anterior portal. The tendon was marked at the pulley insertion on the humerus with a vascular clip before and after the tendon was pulled into the joint. An open deltopectoral approach was performed, and the amount of extra-articular tendon visualized was calculated as an absolute amount and in relation to nearby anatomic structures. An additional 1.9 cm (range, 1.4 to 2.6 cm) of extra-articular LHBT was viewed by pulling the tendon into the joint with an arthroscopic probe through an anterior portal during shoulder arthroscopy. This represented 30.8% of the extra-articular portion of the tendon, 47.7% of tendon in the bicipital groove, and 76.3% of the tendon that lies under the area from the pulley insertion to the distal edge of the transverse humeral ligament. During intra-articular shoulder arthroscopy, the extra-articular portion of the LHBT is incompletely visualized by pulling the tendon into the joint with a probe placed through an anterior portal while viewing through a standard posterior portal. An additional extra-articular portion of the LHBT may be viewed by pulling the tendon into the joint with an arthroscopic probe during shoulder arthroscopy. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  6. Effect of tendon tensioning: an in vitro study in porcine extensor tendons.

    PubMed

    Figueroa, David; Calvo, Rafael; Vaisman, Alex; Meleán, Patricio; Figueroa, Francisco

    2010-06-01

    Graft tensioning is a controversial issue in anterior cruciate ligament reconstruction (ACLR) that has not achieved consensus between peers. The purpose of this study is to determine if after tensioning tendon length and resistance to maximal load changes. We performed an in vitro study with 50 porcine extensors tendons. The first group (P=25) was tensioned with 80 N (19.97 lb) for 10 min, using an ACL graft preparation board. The second group (C=25) was used as control and was not tensioned. The average initial (groups P and C) and post tensioning tendon length (group C) were measured; the average initial and post tensioning tendon diameter were measured as well. All samples were fixated in a tube-clamp system connected to a tension sensor. The samples were stressed with continuous and progressive tension until ultimate failure at maximum load (UFML) occurs. The initial mean length was: P before tensioning=13.4 mm+/-1.4 mm (range 10.5-16.5); P after tensioning=13.8 mm+/-1.4 mm (range 11.5-16.5); C=13 mm+/-1.35 mm (p=0.005). The mean diameter was: P=5.6 mm (4.5-6); C=5.5 mm (range 4.5-6) (p>0.05). The UFML was: P=189.7 N (114-336); C=229.9 N (143-365) (p=0.029). Tendon tensioning with 80 N for 10 min produced 3% average elongation. These could be beneficial in ACLR since tendon tensioning decreases elongation of the graft after fixation. Regardless, tendon tensioning is not innocuous since it diminishes their resistance when continuously stressed until complete failure occurs.

  7. Simultaneous anatomic reconstruction of the acromioclavicular and coracoclavicular ligaments using a single tendon graft.

    PubMed

    Shin, Sang-Jin; Campbell, Sean; Scott, Jonathan; McGarry, Michelle H; Lee, Thay Q

    2014-09-01

    The purpose of this study was to introduce a novel surgical technique for simultaneous anatomic reconstruction of the acromioclavicular and coracoclavicular ligaments using a single tendon graft and to compare its biomechanical characteristics to those of a coracoid cerclage reconstruction of the coracoclavicular ligaments. Six matched pairs of human acromioclavicular joints with an average age of 54.8 ± 7.8 years were used. One shoulder from each pair received the single tendon acromioclavicular-coracoclavicular reconstruction; the contralateral shoulder received the coracoid cerclage reconstruction. Bovine extensor tendon was used for both techniques. The single tendon acromioclavicular-coracoclavicular reconstruction technique provided anatomic restoration of the two coracoclavicular ligaments and the superior and inferior acromioclavicular ligaments simultaneously using one coracoid hole, one acromion hole, and two clavicular holes with interference screws. Anterior-posterior and superior-inferior translations were quantified for all specimens before and after reconstruction, followed by load to failure testing. Following coracoid cerclage reconstruction, total anterior-posterior translation was significantly greater than intact (10.0 ± 5.7 mm; p = 0.008). Following single tendon acromioclavicular-coracoclavicular reconstruction, there was no significant difference in anterior-posterior translation compared to intact (-1.6 ± 2.2 mm; n.s.). The coracoid cerclage technique demonstrated significantly greater anterior-posterior translation than the single tendon acromioclavicular-coracoclavicular technique (p = 0.007). Both techniques restored superior-inferior translation to the intact condition (n.s.). Ultimate load, deformation at ultimate load, and energy absorbed at ultimate load were significantly greater after acromioclavicular-coracoclavicular reconstruction than after coracoid cerclage reconstruction (p < 0.05). This novel single tendon

  8. Anterior cruciate ligament- and hamstring tendon-derived cells: in vitro differential properties of cells involved in ACL reconstruction.

    PubMed

    Ghebes, Corina Adriana; Kelder, Cindy; Schot, Thomas; Renard, Auke J; Pakvis, Dean F M; Fernandes, Hugo; Saris, Daniel B

    2017-04-01

    Anterior cruciate ligament (ACL) reconstruction involves the replacement of the torn ligament with a new graft, often a hamstring tendon (HT). Described as similar, the ACL and HT have intrinsic differences related to their distinct anatomical locations. From a cellular perspective, identifying these differences represents a step forward in the search for new cues that enhance recovery after the reconstruction. The purpose of this study was to characterize the phenotype and multilineage potential of ACL- and HT-derived cells. ACL- and HT-derived cells were isolated from tissue harvest from patients undergoing total knee arthroplasty (TKA) or ACL reconstruction. In total, three ACL and three HT donors were investigated. Cell morphology, self-renewal potential (CFU-F), surface marker profiling, expression of tendon/ligament-related markers (PCR) and multilineage potential were analysed for both cell types; both had fibroblast-like morphology and low self-renewal potential. No differences in the expression of tendon/ligament-related genes or a selected set of surface markers were observed between the two cell types. However, differences in their multilineage potential were observed: while ACL-derived cells showed a high potential to differentiate into chondrocytes and adipocytes, but not osteoblasts, HT-derived cells showed poor potential to form adipocytes, chondrocytes and osteoblasts. Our results demonstrated that HT-derived cells have low multilineage potential compared to ACL-derived cells, further highlighting the need for extrinsic signals to fully restore the function of the ACL upon reconstruction. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  9. A Canine Arthroscopic Anterior Cruciate Ligament Reconstruction Model for Study of Synthetic Augmentation of Tendon Allografts.

    PubMed

    Cook, James L; Smith, Pat; Stannard, James P; Pfeiffer, Ferris; Kuroki, Keiichi; Bozynski, Chantelle C; Cook, Cristi

    2017-09-01

    Novel graft types, fixation methods, and means for augmenting anterior cruciate ligament (ACL) reconstructions require preclinical validation prior to safe and effective clinical application. The objective of this study was to describe and validate a translational canine model for all-inside arthroscopic complete ACL reconstruction using a quadriceps tendon allograft with internal brace (QTIB). With institutional approval, adult research hounds underwent complete transection of the native ACL followed by all-inside ACL reconstruction using the novel QTIB construct with suspensory fixation ( n  = 10). Contralateral knees were used as nonoperated controls ( n  = 10). Dogs were assessed over a 6-month period using functional, diagnostic imaging, gross, biomechanical, and histologic outcome measures required for preclinical animal models. Study results suggest that the novel QTIB construct used for complete ACL reconstruction can provide sustained knee stability and function without the development of premature osteoarthritis in a rigorous and valid preclinical model. The unique configuration of the QTIB construct-the combination of a tendon allograft with a synthetic suture tape internal brace-allowed for an effective biologic-synthetic load-sharing ACL construct. It prevented early failure, allowed for direct, four-zone graft-to-bone healing, and functional graft remodeling while avoiding problems noted with use of all-synthetic grafts. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  10. Succinate dehydrogenase activity and soma size of motoneurons innervating different portions of the rat tibialis anterior

    NASA Technical Reports Server (NTRS)

    Ishihara, A.; Roy, R. R.; Edgerton, V. R.

    1995-01-01

    The spatial distribution, soma size and oxidative enzyme activity of gamma and alpha motoneurons innervating muscle fibres in the deep (away from the surface of the muscle) and superficial (close to the surface of the muscle) portions of the tibialis anterior in normal rats were determined. The deep portion had a higher percentage of high oxidative fibres than the superficial portion of the muscle. Motoneurons were labelled by retrograde neuronal transport of fluorescent tracers: Fast Blue and Nuclear Yellow were injected into the deep portion and Nuclear Yellow into the superficial portion of the muscle. Therefore, motoneurons innervating the deep portion were identified by both a blue fluorescent cytoplasm and a golden-yellow fluorescent nucleus, while motoneurons innervating the superficial portion were identified by only a golden-yellow fluorescent nucleus. After staining for succinate dehydrogenase activity on the same section used for the identification of the motoneurons, soma size and succinate dehydrogenase activity of the motoneurons were measured. The gamma and alpha motoneurons innervating both the deep and superficial portions were located primarily at L4 and were intermingled within the same region of the dorsolateral portion of the ventral horn in the spinal cord. Mean soma size was similar for either gamma or alpha motoneurons in the two portions of the muscle. The alpha motoneurons innervating the superficial portion had a lower mean succinate dehydrogenase activity than those innervating the deep portion of the muscle. An inverse relationship between soma size and succinate dehydrogenase activity of alpha, but not gamma, motoneurons innervating both the deep and superficial portions was observed. Based on three-dimensional reconstructions within the spinal cord, there were no apparent differences in the spatial distribution of the motoneurons, either gamma or alpha, associated with the deep and superficial compartments of the muscle. The data

  11. Intramuscular Pressure of Tibialis Anterior Reflects Ankle Torque but Does Not Follow Joint Angle-Torque Relationship.

    PubMed

    Ateş, Filiz; Davies, Brenda L; Chopra, Swati; Coleman-Wood, Krista; Litchy, William J; Kaufman, Kenton R

    2018-01-01

    Intramuscular pressure (IMP) is the hydrostatic fluid pressure that is directly related to muscle force production. Electromechanical delay (EMD) provides a link between mechanical and electrophysiological quantities and IMP has potential to detect local electromechanical changes. The goal of this study was to assess the relationship of IMP with the mechanical and electrical characteristics of the tibialis anterior muscle (TA) activity at different ankle positions. We hypothesized that (1) the TA IMP and the surface EMG (sEMG) and fine-wire EMG (fwEMG) correlate to ankle joint torque, (2) the isometric force of TA increases at increased muscle lengths, which were imposed by a change in ankle angle and IMP follows the length-tension relationship characteristics, and (3) the electromechanical delay (EMD) is greater than the EMD of IMP during isometric contractions. Fourteen healthy adults [7 female; mean ( SD ) age = 26.9 (4.2) years old with 25.9 (5.5) kg/m 2 body mass index] performed (i) three isometric dorsiflexion (DF) maximum voluntary contraction (MVC) and (ii) three isometric DF ramp contractions from 0 to 80% MVC at rate of 15% MVC/second at DF, Neutral, and plantarflexion (PF) positions. Ankle torque, IMP, TA fwEMG, and TA sEMG were measured simultaneously. The IMP, fwEMG, and sEMG were significantly correlated to the ankle torque during ramp contractions at each ankle position tested. This suggests that IMP captures in vivo mechanical properties of active muscles. The ankle torque changed significantly at different ankle positions however, the IMP did not reflect the change. This is explained with the opposing effects of higher compartmental pressure at DF in contrast to the increased force at PF position. Additionally, the onset of IMP activity is found to be significantly earlier than the onset of force which indicates that IMP can be designed to detect muscular changes in the course of neuromuscular diseases impairing electromechanical transmission.

  12. Non-invasive measurement of tibialis anterior muscle temperature during rest, cycling exercise and post-exercise recovery.

    PubMed

    Flouris, Andreas D; Dinas, Petros C; Tsitoglou, Kiriakos; Patramani, Ioanna; Koutedakis, Yiannis; Kenny, Glen P

    2015-07-01

    We introduce a non-invasive and accurate method to assess tibialis anterior muscle temperature (Tm) during rest, cycling exercise, and post-exercise recovery using the insulation disk (INDISK) technique. Twenty-six healthy males (23.6  ±  6.2 years; 24.1  ±  3.1 body mass index) were randomly allocated into the 'model' (n = 16) and the 'validation' (n = 10) groups. Participants underwent 20 min supine rest, 20 min cycling exercise at 60% of age-predicted maximum heart rate, and 20 min supine post-exercise recovery. In the model group, Tm (34.55  ±  1.02 °C) was greater than INDISK temperature (Tid; 32.44  ±  1.23 °C; p < 0.001) and skin surface temperature (Tsk; 29.84  ±  1.47 °C; p < 0.001) throughout the experimental protocol. The strongest prediction model (R(2) = 0.646) incorporated Tid and the difference between the current Tid temperature and that recorded four minutes before. No mean difference (p > 0.05) and a strong correlation (r = 0.804; p < 0.001) were observed between Tm and predicted Tm (predTm) in the model group. Cross-validation analyses in the validation group demonstrated no mean difference (p > 0.05), a strong correlation (r = 0.644; p < 0.001), narrow 95% limits of agreement (-0.06  ±  1.51), and low percent coefficient of variation (2.24%) between Tm (34.39  ±  1.00 °C) and predTm (34.45  ±  0.73 °C). We conclude that the novel technique accurately predicts Tm during rest, cycling exercise, and post-exercise recovery, providing a valid and cost-efficient alternative when direct Tm measurement is not feasible.

  13. Augmentation of autologous hamstring graft during anterior cruciate ligament reconstruction using the bone chip technique.

    PubMed

    Nha, Kyung Wook; Shetty, Gautam M; Ahn, Jin Hwan; Lee, Yong Seuk; Chae, Dong Ju; Nam, Hyok Woo; Lee, Dae Hee

    2010-01-01

    The use of autologous quadrupled hamstring tendon graft is a well-known technique for anterior cruciate ligament reconstruction. In cases where the diameter of the graft is inadequate, the stability of graft fixation and subsequent bone to tendon healing may be compromised. We describe a new technique to augment the autologous double looped hamstring tendon graft during anterior cruciate ligament reconstruction using cancellous bone chips. This simple technique effectively enhances graft fixation and stability.

  14. Surgical repair of chronic patellar tendon rupture in total knee replacement with ipsilateral hamstring tendons.

    PubMed

    Spoliti, Marco; Giai Via, Alessio; Padulo, Johnny; Oliva, Francesco; Del Buono, Angelo; Maffulli, Nicola

    2016-10-01

    Patellar tendon rupture is a serious complication of total knee arthroplasty (TKA). Its reconstruction in patients with chronic ruptures is technically demanding. This article reports the results of surgical reconstruction of neglected patellar tendon rupture in TKA using autologous hamstring tendons. Nine TKA patients (six women and three men) (mean age at index surgery 68 years) with chronic patellar tendon tears underwent reconstruction with ipsilateral hamstrings tendon, leaving the distal insertion in situ. The clinical diagnosis was supported by imaging (anterior-posterior and 30° flexion lateral radiographs). Insall-Salvati index, range of motion, and leg extension test were recorded preoperatively and at last follow-up. The modified Cincinnati rating system and the Kujala score were administered. The patients sustained the patellar tendon tear an average of 8 weeks before the procedure. At final follow-up of 4 years (range 2-8 years), the median of extension lag was 5° (range 0°-15°; DS = 5). The median of post-operative Insall-Salvati index was 1.4 (range 1.3-1.8; SD = 0.15; p = 0.002) compared to the preoperative index of 1.7 (range 1.5-2.2; SD = 0.23). The mean modified Cincinnati and Kujala scores significantly increased compared with the preoperative ones (p < 0.01). At final follow-up, all patients were able to walk without brace or aids, and they were satisfied with the procedure. Based on our retrospective study of nine patients, reconstruction of neglected patellar tendon rupture in TKA with autologous hamstring tendons is feasible and safe, and provides good functional recovery. Case series, Level IV.

  15. Tunnel widening prevention with the allo-Achilles tendon graft in anterior cruciate ligament reconstruction: Surgical tips and short term followup

    PubMed Central

    Suh, Dong Won; Han, Seung Beom; Yeo, Woo Jin; Lee, Won Hee; Kwon, Jae Ho; Kyung, Bong Soo

    2017-01-01

    Background: Tunnel widening (TW) after anterior cruciate ligament (ACL) reconstruction can be a serious complication, and there is controversy over how to prevent it. This study aimed to suggest surgical approaches to prevent TW using an allo-Achilles tendon graft, and then to evaluate TW after these surgical tips were applied. Materials and Methods: Sixty two patients underwent ACL reconstruction with an allo-Achilles tendon graft. Four surgical approaches were used: Making a tibial tunnel by bone impaction, intraarticular reamer application, bone portion application for the femoral tunnel, and an additional bone plug application for the tibial tunnel. After more than 1-year, followup radiographs including anteroposterior and lateral views were taken in 29 patients encompassing thirty knees. The diameter of the tunnels at postoperation day 1 (POD1) and at followup was measured and compared. Results: In 18 knees (60%), there were no visible femoral tunnel margins on the radiographs at POD1 or followup. In the other 12 cases, which had visible femoral tunnel margins on followup radiographs, the mean femoral tunnel diameter was 8.6 mm. In the tibial tunnel, the mean diameters did not increase on all three levels (proximal, middle, and distal), and there was no statistically significant difference between the diameters at POD1 and followup. Conclusion: The suggested tips for surgery involving an allo-Achilles tendon graft can effectively prevent TW after ACL reconstruction according to this case series. These surgical tips can prevent TW. PMID:28400663

  16. Effect of Immediate and Delayed High-Strain Loading on Tendon-to-Bone Healing After Anterior Cruciate Ligament Reconstruction

    PubMed Central

    Packer, Jonathan D.; Bedi, Asheesh; Fox, Alice J.; Gasinu, Selom; Imhauser, Carl W.; Stasiak, Mark; Deng, Xiang-Hua; Rodeo, Scott A.

    2014-01-01

    Background: We previously demonstrated, in a rat anterior cruciate ligament (ACL) graft reconstruction model, that the delayed application of low-magnitude-strain loading resulted in improved tendon-to-bone healing compared with that observed after immediate loading and after prolonged immobilization. The purpose of this study was to determine the effect of higher levels of strain loading on tendon-to-bone healing. Methods: ACL reconstruction was carried out in a rat model in three randomly assigned groups: high-strain daily loading beginning on either (1) postoperative day one (immediate-loading group; n = 7) or (2) postoperative day four (delayed-loading group; n = 11) or (3) after prolonged immobilization (immobilized group; n = 8). Animals were killed two weeks after surgery and micro-computed tomography (micro-CT) and biomechanical testing of the bone-tendon-bone complex were carried out. Results: The delayed-loading group had greater tissue mineral density than either the immediate-loading or immobilized group (mean [and standard deviation], 813.0 ± 24.9 mg/mL compared with 778.4 ± 32.6 mg/mL and 784.9 ± 26.4 mg/mL, respectively; p < 0.05). There was a trend toward greater bone volume per total volume fraction in both the immobilized and the delayed-loading group compared with the immediate-loading group (0.24 ± 0.03 and 0.23 ± 0.06 compared with 0.20 ± 0.05; p = 0.06). Trabecular thickness was greater in the immobilized group compared with the immediate-loading group (106.5 ± 23.0 μm compared with 72.6 ± 10.6 μm; p < 0.01). There were no significant differences in failure load or stiffness between the immobilized group and either high-strain cyclic-loading group. Conclusions: Immediate application of high-strain loading appears to have a detrimental effect on healing in this rat model. Any beneficial effects of delayed loading on the healing tendon-bone interface (after a brief period of immobilization) may be offset by the detrimental effects of

  17. Morphologic Characteristics and Strength of the Hamstring Muscles Remain Altered at 2 Years After Use of a Hamstring Tendon Graft in Anterior Cruciate Ligament Reconstruction.

    PubMed

    Konrath, Jason M; Vertullo, Christopher J; Kennedy, Ben A; Bush, Hamish S; Barrett, Rod S; Lloyd, David G

    2016-10-01

    The hamstring tendon graft used in anterior cruciate ligament (ACL) reconstruction has been shown to lead to changes to the semitendinosus and gracilis musculature. We hypothesized that (1) loss of donor muscle size would significantly correlate with knee muscle strength deficits, (2) loss of donor muscle size would be greater for muscles that do not experience tendon regeneration, and (3) morphological adaptations would also be evident in nondonor knee muscles. Cross-sectional study; Level of evidence, 3. Twenty participants (14 men and 6 women, mean age 29 ± 7 years, mean body mass 82 ± 15 kg) who had undergone an ACL reconstruction with a hamstring tendon graft at least 2 years previously underwent bilateral magnetic resonance imaging and subsequent strength testing. Muscle and tendon volumes, peak cross-sectional areas (CSAs), and lengths were determined for 12 muscles and 6 functional muscle groups of the surgical and contralateral limbs. Peak isokinetic concentric strength was measured in knee flexion/extension and internal/external tibial rotation. Only 35% of the patients showed regeneration of both the semitendinosus and gracilis tendons. The regenerated tendons were longer with larger volume and CSA compared with the contralateral side. Deficits in semitendinosus and gracilis muscle size were greater for muscles in which tendons did not regenerate. In addition, combined hamstring muscles (semitendinosus, semimembranosus, and biceps femoris) and combined medial knee muscles (semitendinosus, semimembranosus, gracilis, vastus medialis, medial gastrocnemius, and sartorius) on the surgical side were reduced in volume by 12% and 10%, respectively. A 7% larger volume was observed in the surgical limb for the biceps femoris muscle and corresponded with a lower internal/external tibial rotation strength ratio. The difference in volume, peak CSA, and length of the semitendinosus and gracilis correlated significantly with the deficit in knee flexion strength, with

  18. Dependence of the paired motor unit analysis on motor unit discharge characteristics in the human tibialis anterior muscle

    PubMed Central

    Stephenson, Jennifer L.; Maluf, Katrina S.

    2011-01-01

    The paired motor unit analysis provides in vivo estimates of the magnitude of persistent inward currents (PIC) in human motoneurons by quantifying changes in the firing rate (ΔF) of an earlier recruited (reference) motor unit at the time of recruitment and derecruitment of a later recruited (test) motor unit. This study assessed the variability of ΔF estimates, and quantified the dependence of ΔF on the discharge characteristics of the motor units selected for analysis. ΔF was calculated for 158 pairs of motor units recorded from nine healthy individuals during repeated submaximal contractions of the tibialis anterior muscle. The mean (SD) ΔF was 3.7 (2.5) pps (range −4.2 to 8.9 pps). The median absolute difference in ΔF for the same motor unit pair across trials was 1.8 pps, and the minimal detectable change in ΔF required to exceed measurement error was 4.8 pps. ΔF was positively related to the amount of discharge rate modulation in the reference motor unit (r2=0.335; P<0.001), and inversely related to the rate of increase in discharge rate (r2=0.125; P<0.001). A quadratic function provided the best fit for relations between ΔF and the time between recruitment of the reference and test motor units (r2=0.229, P<0.001), the duration of test motor unit activity (r2=0.110, P<0.001), and the recruitment threshold of the test motor unit (r2=0.237, P<0.001). Physiological and methodological contributions to the variability in ΔF estimates of PIC magnitude are discussed, and selection criteria to reduce these sources of variability are suggested for the paired motor unit analysis. PMID:21459110

  19. The age related slow and fast contributions to the overall changes in tibialis anterior contractile features disclosed by maximal single twitch scan.

    PubMed

    Orizio, Claudio; Cogliati, Marta; Bissolotti, Luciano; Diemont, Bertrand; Gobbo, Massimiliano; Celichowski, Jan

    2016-01-01

    This work aimed to verify if maximal electrically evoked single twitch (STmax) scan discloses the relative functional weight of fast and slow small bundles of fibres (SBF) in determining the contractile features of tibialis anterior (TA) with ageing. SBFs were recruited by TA main motor point stimulation through 60 increasing levels of stimulation (LS): 20 stimuli at 2Hz for each LS. The lowest and highest LS provided the least ST and STmax, respectively. The scanned STmax was decomposed into individual SBF STs. They were identified when twitches from adjacent LS were significantly different and then subtracted from each other. Nine young (Y) and eleven old (O) subjects were investigated. Contraction time (CT) and STarea/STpeak (A/PT) were calculated per each SBF ST. 143 and 155 SBF STs were obtained in Y and O, respectively. Y: CT and A/PT range: 45-105ms and 67-183mNs/mN, respectively. Literature data set TA fast fibres at 34% so, from the arrays of CT and A/PT, 65ms and 100mNs/mN were identified as the upper limit for SBF fast ST classification. O: no SBF ST could be classified as fast. STmax scan reveals age-related changes in the relative contribution of fast and slow SBFs to the overall muscle mechanics. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. The effect of different decline angles on the biomechanics of double limb squats and the implications to clinical and training practice.

    PubMed

    Richards, Jim; Selfe, James; Sinclair, Jonathan; May, Karen; Thomas, Gavin

    2016-09-01

    Bilateral decline squatting has been well documented as a rehabilitation exercise, however, little information exists on the optimum angle of decline. The aim of this study was to determine the ankle and knee angle, moments, the patellofemoral joint load, patellar tendon load and associated muscle activity while performing a double limb squat at different decline angles and the implications to rehabilitation. Eighteen healthy subjects performed double limb squats at 6 angles of declination: 0, 5, 10, 15, 20 and 25 degrees. The range of motion of the knee and ankle joints, external moments, the patellofemoral/patellar tendon load and integrated EMG of gastrocnemius, tibialis anterior, rectus femoris and biceps femoris were evaluated. As the decline angle increased up to 20 degrees, the range of motion possible at the ankle and knee increased. The joint moments showed a decrease at the ankle up to 15 degrees and an increase at the knee up to 25 degrees, indicating a progressive reduction in loading around the ankle with a corresponding increase of the load in the patellar tendon and patellofemoral joint. These trends were supported by a decrease in tibialis anterior activity and an increase in the rectus femoris activity up to 15 degrees declination. However, gastrocnemius and biceps femoris activity increased as the decline angle increased above 15 degrees. The action of gastrocnemius and biceps femoris stabilises the knee against an anterior displacement of the femur on the tibia. These findings would suggest that there is little benefit in using a decline angle greater than 15-20 degrees unless the purpose is to offer an additional stability challenge to the knee joint.

  1. The effect of different decline angles on the biomechanics of double limb squats and the implications to clinical and training practice

    PubMed Central

    Richards, Jim; Selfe, James; Sinclair, Jonathan; May, Karen; Thomas, Gavin

    2016-01-01

    Abstract Bilateral decline squatting has been well documented as a rehabilitation exercise, however, little information exists on the optimum angle of decline. The aim of this study was to determine the ankle and knee angle, moments, the patellofemoral joint load, patellar tendon load and associated muscle activity while performing a double limb squat at different decline angles and the implications to rehabilitation. Eighteen healthy subjects performed double limb squats at 6 angles of declination: 0, 5, 10, 15, 20 and 25 degrees. The range of motion of the knee and ankle joints, external moments, the patellofemoral/patellar tendon load and integrated EMG of gastrocnemius, tibialis anterior, rectus femoris and biceps femoris were evaluated. As the decline angle increased up to 20 degrees, the range of motion possible at the ankle and knee increased. The joint moments showed a decrease at the ankle up to 15 degrees and an increase at the knee up to 25 degrees, indicating a progressive reduction in loading around the ankle with a corresponding increase of the load in the patellar tendon and patellofemoral joint. These trends were supported by a decrease in tibialis anterior activity and an increase in the rectus femoris activity up to 15 degrees declination. However, gastrocnemius and biceps femoris activity increased as the decline angle increased above 15 degrees. The action of gastrocnemius and biceps femoris stabilises the knee against an anterior displacement of the femur on the tibia. These findings would suggest that there is little benefit in using a decline angle greater than 15-20 degrees unless the purpose is to offer an additional stability challenge to the knee joint. PMID:28149400

  2. Low-Level Laser Therapy (808 nm) Reduces Inflammatory Response and Oxidative Stress in Rat Tibialis Anterior Muscle After Cryolesion

    PubMed Central

    Assis, Lívia; Moretti, Ana I.S.; Abrahão, Thalita B.; Cury, Vivian; Souza, Heraldo P.; Hamblin, Michael R.; Parizotto, Nivaldo A.

    2012-01-01

    Background and Objective Muscle regeneration is a complex phenomenon, involving coordinated activation of several cellular responses. During this process, oxidative stress and consequent tissue damage occur with a severity that may depend on the intensity and duration of the inflammatory response. Among the therapeutic approaches to attenuate inflammation and increase tissue repair, low-level laser therapy (LLLT) may be a safe and effective clinical procedure. The aim of this study was to evaluate the effects of LLLT on oxidative/nitrative stress and inflammatory mediators produced during a cryolesion of the tibialis anterior (TA) muscle in rats. Material and Methods Sixty Wistar rats were randomly divided into three groups (n = 20): control (BC), injured TA muscle without LLLT (IC), injured TA muscle submitted to LLLT (IRI). The injured region was irradiated daily for 4 consecutive days, starting immediately after the lesion using a AlGaAs laser (continuous wave, 808 nm, tip area of 0.00785 cm2, power 30 mW, application time 47 seconds, fluence 180 J/cm2; 3.8 mW/cm2; and total energy 1.4 J). The animals were sacrificed on the fourth day after injury. Results LLLT reduced oxidative and nitrative stress in injured muscle, decreased lipid peroxidation, nitrotyrosine formation and NO production, probably due to reduction in iNOS protein expression. Moreover, LLLT increased SOD gene expression, and decreased the inflammatory response as measured by gene expression of NF-kβ and COX-2 and by TNF-α and IL-1β concentration. Conclusion These results suggest that LLLT could be an effective therapeutic approach to modulate oxidative and nitrative stress and to reduce inflammation in injured muscle. PMID:23001637

  3. Low-level laser therapy (808 nm) reduces inflammatory response and oxidative stress in rat tibialis anterior muscle after cryolesion.

    PubMed

    Assis, Lívia; Moretti, Ana I S; Abrahão, Thalita B; Cury, Vivian; Souza, Heraldo P; Hamblin, Michael R; Parizotto, Nivaldo A

    2012-11-01

    Muscle regeneration is a complex phenomenon, involving coordinated activation of several cellular responses. During this process, oxidative stress and consequent tissue damage occur with a severity that may depend on the intensity and duration of the inflammatory response. Among the therapeutic approaches to attenuate inflammation and increase tissue repair, low-level laser therapy (LLLT) may be a safe and effective clinical procedure. The aim of this study was to evaluate the effects of LLLT on oxidative/nitrative stress and inflammatory mediators produced during a cryolesion of the tibialis anterior (TA) muscle in rats. Sixty Wistar rats were randomly divided into three groups (n = 20): control (BC), injured TA muscle without LLLT (IC), injured TA muscle submitted to LLLT (IRI). The injured region was irradiated daily for 4 consecutive days, starting immediately after the lesion using a AlGaAs laser (continuous wave, 808 nm, tip area of 0.00785 cm(2) , power 30 mW, application time 47 seconds, fluence 180 J/cm(2) ; 3.8 mW/cm(2) ; and total energy 1.4 J). The animals were sacrificed on the fourth day after injury. LLLT reduced oxidative and nitrative stress in injured muscle, decreased lipid peroxidation, nitrotyrosine formation and NO production, probably due to reduction in iNOS protein expression. Moreover, LLLT increased SOD gene expression, and decreased the inflammatory response as measured by gene expression of NF-kβ and COX-2 and by TNF-α and IL-1β concentration. These results suggest that LLLT could be an effective therapeutic approach to modulate oxidative and nitrative stress and to reduce inflammation in injured muscle. Copyright © 2012 Wiley Periodicals, Inc.

  4. Posterior Displacement of Supraspinatus Central Tendon Observed on Magnetic Resonance Imaging: A Useful Preoperative Indicator of Rotator Cuff Tear Characteristics.

    PubMed

    Updegrove, Gary F; Armstrong, April D; Mosher, Timothy J; Kim, H Mike

    2015-11-01

    To characterize the orientation of the normal supraspinatus central tendon and describe the displacement patterns of the central tendon in rotator cuff tears using a magnetic resonance imaging (MRI)-based method. We performed a retrospective MRI and chart review of 183 patients with a rotator cuff tear (cuff tear group), 52 with a labral tear but no rotator cuff tear (labral tear group), and 74 with a normal shoulder (normal group). The orientation of the supraspinatus central tendon relative to the bicipital groove was evaluated based on axial MRI and was numerically represented by the shortest distance from the lateral extension line of the central tendon to the bicipital groove. Tear size, fatty degeneration, and involvement of the anterior supraspinatus were evaluated to identify the factors associated with orientation changes. The mean distance from the bicipital groove to the central tendon line was 0.7 mm and 1.3 mm in the normal group and labral tear group, respectively. Full-thickness cuff tears involving the anterior supraspinatus showed a significantly greater distance (17.7 mm) than those sparing the anterior supraspinatus (4.9 mm, P = .001). Fatty degeneration of the supraspinatus was significantly correlated with the distance (P = .006). Disruption of the anterior supraspinatus and fatty degeneration of the supraspinatus were independent predictors of posterior displacement. The supraspinatus central tendon has a constant orientation toward the bicipital groove in normal shoulders, and the central tendon is frequently displaced posteriorly in full-thickness rotator cuff tears involving the anterior leading edge of the supraspinatus. The degree of posterior displacement is proportional to tear size and severity of fatty degeneration of the supraspinatus muscle. A simple and quick assessment of the central tendon orientation on preoperative MRI can be a useful indicator of tear characteristics, potentially providing insight into the intraoperative

  5. A rare knee extensor mechanism injury: Vastus intermedius tendon rupture.

    PubMed

    Cetinkaya, Engin; Aydin, Canan Gonen; Akman, Yunus Emre; Gul, Murat; Arikan, Yavuz; Aycan, Osman Emre; Kabukcuoglu, Yavuz Selim

    2015-01-01

    Quadriceps tendon injuries are rare. There is a limited number of studies in the literature, reporting partial quadriceps tendon ruptures. We did not find any study reporting an isolated vastus intermedius tendon injury in the literature. A 22 years old professional rugby player with the complaints of pain in the right lower limb, decreased range of motion in right knee and a mass in the mid-anterior of the right thigh applied following an overloading on his hyperflexed knee during a rugby match. T2 sequence magnetic resonance images revealed discontinuity in the vastus intermedius tendon and intramuscular hematoma. The patient has been conservatively treated. Quadriceps tendon ruptures generally occur after the 4th decade in the presence of degenerative changes. Our case is a young professional rugby player. Isolated vastus intermedius tendon rupture is unusual. Conservative treatment is performed as the intermedius tendon is in the deepest layer of the quadriceps muscle. We report the first case of isolated rupture of the vastus intermedius tendon in the literature and we claim that disorder may be succesfully treated with conservative treatment and adequate physiotheraphy. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. A rare knee extensor mechanism injury: Vastus intermedius tendon rupture

    PubMed Central

    Cetinkaya, Engin; Aydin, Canan Gonen; Akman, Yunus Emre; Gul, Murat; Arikan, Yavuz; Aycan, Osman Emre; Kabukcuoglu, Yavuz Selim

    2015-01-01

    Introduction Quadriceps tendon injuries are rare. There is a limited number of studies in the literature, reporting partial quadriceps tendon ruptures. We did not find any study reporting an isolated vastus intermedius tendon injury in the literature. Presentation of case A 22 years old professional rugby player with the complaints of pain in the right lower limb, decreased range of motion in right knee and a mass in the mid-anterior of the right thigh applied following an overloading on his hyperflexed knee during a rugby match. T2 sequence magnetic resonance images revealed discontinuity in the vastus intermedius tendon and intramuscular hematoma. The patient has been conservatively treated. Discussion Quadriceps tendon ruptures generally occur after the 4th decade in the presence of degenerative changes. Our case is a young professional rugby player. Isolated vastus intermedius tendon rupture is unusual. Conservative treatment is performed as the intermedius tendon is in the deepest layer of the quadriceps muscle. Conclusion We report the first case of isolated rupture of the vastus intermedius tendon in the literature and we claim that disorder may be succesfully treated with conservative treatment and adequate physiotheraphy. PMID:26298093

  7. Ultrasound-guided steroid tendon sheath injections in juvenile idiopathic arthritis: a 10-year single-center retrospective study.

    PubMed

    Peters, Shannon E; Laxer, Ronald M; Connolly, Bairbre L; Parra, Dimitri A

    2017-04-11

    The aims of this study were to: (a) Identify tendon sheaths most commonly treated with steroid injections in a pediatric patient population with Juvenile Idiopathic Arthritis (JIA); (b) Describe technical aspects of the procedure; (c) Characterize sonographic appearance of tenosynovitis in JIA; (d) Assess agreement between clinical request and sites injected. This was a 10 year single-center retrospective study (May 2006-April 2016) of patients with JIA referred by Rheumatology for ultrasound-guided tendon sheath injections. Patient demographics, clinical referral information, sonographic appearance of the tendon sheaths and technical aspects of the procedure were analyzed. There were 308 procedures of 244 patients (75% female, mean age 9.6 years) who underwent a total of 926 tendon sheath injections. Ankle tendons were most commonly injected (84.9%), specifically the tendon sheaths of tibialis posterior (22.3%), peroneus longus (20%) and brevis (19.7%). The majority of treated sites (91.9%) showed peritendinous fluid and sheath thickening on ultrasound. There were 2 minor intra-procedure complications without sequelae. A good agreement between clinical request and sites injected was observed. Ultrasound-guided tendon sheath injections with steroids are used frequently to treat patients with JIA. It is a safe intervention with a high technical success rate. The ankle region, specifically the medial compartment, is the site most commonly injected in this group of patients. The most common sonographic finding is peritendinous fluid and sheath thickening. These findings might assist clinicians and radiologists to characterize and more effectively manage tenosynovitis in patients with JIA.

  8. Modulation of plantar pressure and gastrocnemius activity during gait using electrical stimulation of the tibialis anterior in healthy adults

    PubMed Central

    Ueno, Mizuki; Yoshikawa, Yoshiyuki; Terashi, Hiroto; Fujino, Hidemi

    2018-01-01

    High plantar flexor moment during the stance phase is known to cause high plantar pressure under the forefoot; however, the effects on plantar pressure due to a change of gastrocnemius medialis (GM) activity during gait, have not been investigated to date. Reciprocal inhibition is one of the effects of electrical stimulation (ES), and is the automatic antagonist alpha motor neuron inhibition which is evoked by excitation of the agonist muscle. The aim of this study was to investigate the influences of ES of the tibialis anterior (TA) on plantar pressure and the GM activity during gait in healthy adults. ES was applied to the TAs of twenty healthy male adults for 30 minutes at the level of intensity that causes a full range of dorsiflexion in the ankle (frequency; 50 Hz, on-time; 10 sec, off-time; 10 sec). Subjects walked 10 meters before and after ES, and we measured the peak plantar pressure (PP), pressure time integral (PTI), and gait parameters by using an F-scan system. The percentage of integrated electromyogram (%IEMG), active time, onset time, peak time, and cessation time of TA and GM were calculated. PP and PTI under the forefoot, rear foot, and total plantar surface significantly decreased after the application of ES. Meanwhile, changes of gait parameters were not observed. %IEMG and the active time of both muscles did not change; however, onset time and peak time of GM became significantly delayed. ES application to the TA delayed the timing of onset and peak in the GM, and caused the decrease of plantar pressure during gait. The present results suggest that ES to the TA could become a new method for the control of plantar pressure via modulation of GM activity during gait. PMID:29746498

  9. Autologous platelet-rich plasma gel to reduce donor-site morbidity after patellar tendon graft harvesting for anterior cruciate ligament reconstruction: a randomized, controlled clinical study.

    PubMed

    Cervellin, M; de Girolamo, L; Bait, C; Denti, M; Volpi, P

    2012-01-01

    Bone-patellar tendon-bone technique (BPTB) for anterior cruciate ligament injuries is associated with a higher risk of donor-site morbidity. To evaluate whether platelet-rich plasma (PRP), due to its anti-inflammatory properties and capacity to stimulate tissue regeneration, was able to reduce the anterior knee pain, the kneeling pain, and donor-site morbidity, as evidenced by evaluation of VISA and VAS scoring scales and MRI analysis of the tendon and bone defect, we performed a clinical randomized controlled study where PRP gel was applied to donor site after ACL reconstruction with BPTB. Forty young athletes with the indication of ACL reconstruction with patellar tendon grafts were randomly assigned to group A (n = 20 patients, control group) or group B (n = 20 patients, PRP group). The autologous PRP gel was applied to both the patellar and tendon bone plug harvest site and stabilized by the peritenon suture. At 12-month follow-up, all patients underwent clinical examination and VAS and VISA questionnaires, respectively, evaluating the average daily pain of the knee and the pain during particular activities involving the knee, were filled. MRI at the same time point was also performed. VISA scores were significantly higher in the patients treated with PRP (84.5 ± 11.8 and 97.8 ± 2.5 for group A and for group B; P = 0.041), whereas no significant difference in postoperative VAS scores between the two groups was observed (1 ± 1.4 and 0.6 ± 0.9 for group A and group B, n.s.). In 85% of PRP group patients, the tibial and patellar bone defect was satisfactorily filled by new bony tissue (>70% of bone gap filled), whereas this percentage was just of 60% in control group patients, but this difference was not statistically significant. The study shows the usefulness of PRP in reducing subjective pain at the donor-site level after ACL reconstruction with BPTB. However, this approach deserves further investigations to confirm PRP efficacy and to

  10. The role of the bicipital groove in tendopathy of the long biceps tendon.

    PubMed

    Pfahler, M; Branner, S; Refior, H J

    1999-01-01

    Long biceps tendon disease is often underrated but plays an important role in anterior shoulder pain. We studied prospectively the anatomy of the bicipital groove and its relationship to clinical symptoms. Sixty-seven consecutive patients were investigated by mutual ultrasonography and radiographs of the intertubercular groove. All images were scrutinized for biceps tendon status (ultrasonography) and groove anatomy (radiography). Thirty-seven patients (21 male, 16 female, average age 48 years) had chronic anterior shoulder pain, and 30 patients (16 male, 14 female, average age 46 years) served as a control group. In 28 shoulders we found sonographic signs of tendovaginitis, and in 14 we found degenerative changes. The mean age of patients with pathologic conditions of the long biceps tendon was 40 years, significantly lower than that of the complete study group. The x-ray films revealed a great variation in the medial and total opening angle of the groove, whereas width, depth, and humeral head diameter showed sex-related differences. Radiologic signs of groove degeneration correlated in 43.6% with biceps tendon disease on the sonogram. Our study revealed statistically significant correlations between groove anatomy and long biceps tendon disease, which should be considered more while shoulder problems are evaluated.

  11. Sensitivity of subject-specific models to Hill muscle-tendon model parameters in simulations of gait.

    PubMed

    Carbone, V; van der Krogt, M M; Koopman, H F J M; Verdonschot, N

    2016-06-14

    Subject-specific musculoskeletal (MS) models of the lower extremity are essential for applications such as predicting the effects of orthopedic surgery. We performed an extensive sensitivity analysis to assess the effects of potential errors in Hill muscle-tendon (MT) model parameters for each of the 56 MT parts contained in a state-of-the-art MS model. We used two metrics, namely a Local Sensitivity Index (LSI) and an Overall Sensitivity Index (OSI), to distinguish the effect of the perturbation on the predicted force produced by the perturbed MT parts and by all the remaining MT parts, respectively, during a simulated gait cycle. Results indicated that sensitivity of the model depended on the specific role of each MT part during gait, and not merely on its size and length. Tendon slack length was the most sensitive parameter, followed by maximal isometric muscle force and optimal muscle fiber length, while nominal pennation angle showed very low sensitivity. The highest sensitivity values were found for the MT parts that act as prime movers of gait (Soleus: average OSI=5.27%, Rectus Femoris: average OSI=4.47%, Gastrocnemius: average OSI=3.77%, Vastus Lateralis: average OSI=1.36%, Biceps Femoris Caput Longum: average OSI=1.06%) and hip stabilizers (Gluteus Medius: average OSI=3.10%, Obturator Internus: average OSI=1.96%, Gluteus Minimus: average OSI=1.40%, Piriformis: average OSI=0.98%), followed by the Peroneal muscles (average OSI=2.20%) and Tibialis Anterior (average OSI=1.78%) some of which were not included in previous sensitivity studies. Finally, the proposed priority list provides quantitative information to indicate which MT parts and which MT parameters should be estimated most accurately to create detailed and reliable subject-specific MS models. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Partially irreversible paresis of the deep peroneal nerve caused by osteocartilaginous exostosis of the fibula without affecting the tibialis anterior muscle.

    PubMed

    Paprottka, Felix Julian; Machens, Hans-Günther; Lohmeyer, Jörn Andreas

    2012-08-01

    Dysfunction of the lower limb's muscles can cause severe impairment and immobilisation of the patient. As one of the leg's major motor and sensory nerves, the deep peroneal nerve (synonym: deep fibular nerve) plays a very important role in muscle innervation in the lower extremities. We report the case of a 19-year-old female patient, who suffered from a brace-like exostosis 6-cm underneath her left fibular head causing a partially irreversible paresis of her deep peroneal nerve. This nerve damage resulted in complete atrophy of her extensor digitorum longus and extensor hallucis longus muscle, and in painful sensory disturbance at her left shin and first web space. The tibialis anterior muscle stayed intact because its motor branch left the deep peroneal nerve proximal to the nerve lesion. Diagnosis was first verified 6 years after the onset of symptoms by a magnetic resonance imaging (MRI) scan of her complete left lower leg. Subsequently, the patient was operated on in our clinic, where a neurolysis was performed and the 4-cm-long osteocartilaginous exostosis was removed. Paralysis was already irreversible but sensibility returned completely after neurolysis. The presented case shows that an osteocartilaginous exostosis can be the cause for partial deep peroneal nerve paresis. If this disorder is diagnosed at an early stage, nerve damage is reversible. Typical for an exostosis is its first appearance during the juvenile growth phase. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. [Application of silk-based tissue engineering scaffold for tendon / ligament regeneration].

    PubMed

    Hu, Yejun; Le, Huihui; Jin, Zhangchu; Chen, Xiao; Yin, Zi; Shen, Weiliang; Ouyang, Hongwei

    2016-03-01

    Tendon/ligament injury is one of the most common impairments in sports medicine. The traditional treatments of damaged tissue repair are unsatisfactory, especially for athletes, due to lack of donor and immune rejection. The strategy of tissue engineering may break through these limitations, and bring new hopes to tendon/ligament repair, even regeneration. Silk is a kind of natural biomaterials, which has good biocompatibility, wide range of mechanical properties and tunable physical structures; so it could be applied as tendon/ligament tissue engineering scaffolds. The silk-based scaffold has robust mechanical properties; combined with other biological ingredients, it could increase the surface area, promote more cell adhesion and improve the biocompatibility. The potential clinical application of silk-based scaffold has been confirmed by in vivo studies on tendon/ligament repairing, such as anterior cruciate ligament, medial collateral ligament, achilles tendon and rotator cuff. To develop novel biomechanically stable and host integrated tissue engineered tendon/ligament needs more further micro and macro studies, combined with product development and clinical application, which will give new hope to patients with tendon/ligament injury.

  14. A retrospective review of bone tunnel enlargement after anterior cruciate ligament reconstruction with hamstring tendons fixed with a metal round cannulated interference screw in the femur.

    PubMed

    Kobayashi, Masahiko; Nakagawa, Yasuaki; Suzuki, Takashi; Okudaira, Shuzo; Nakamura, Takashi

    2006-10-01

    To assess bone tunnel enlargement after anterior cruciate ligament (ACL) reconstruction with the use of hamstring tendons fixed with a round cannulated interference (RCI) screw in the femur. A consecutive series of 30 ACL reconstructions performed with hamstring tendons fixed with an RCI screw in the femur and with staples via Leeds-Keio ligament in the tibia was retrospectively reviewed. The clinical outcome was evaluated through the Lysholm score. Anterior instability was tested by Telos-SE (Telos Japan, Tokyo, Japan) measurement. The location and angle of each femoral and tibial tunnel were measured with the use of plain radiographs, and bone tunnel enlargement greater than 2 mm detected any time 3, 6, 12, and 24 months postoperatively was defined as positive. Each factor (location and angle of the tunnels, sex, affected side, age, Lysholm score, and Telos-SE measurement) was compared between enlarged and nonenlarged groups. Positive enlargement of the bone tunnel (>2.0 mm) was observed in 36.7% (11 of 30) on the femoral side and 33.3% (10 of 30) on the tibial side, and in 6 knees of both sides. Half of patients (15 of 30) had an enlarged tunnel on the femoral or the tibial side until 1 year postoperatively. In most cases, enlargement reached maximum at 6 months postoperatively. Female patients tended to have an enlarged tunnel, especially on the femoral side (P < .05). Tunnel enlargement was not correlated with location and angle of the tunnels. Moreover, no difference was found in Lysholm score and Telos-SE measurement between enlarged and nonenlarged groups, although the nonenlarged group tended to exhibit higher Lysholm score and lesser instability. Bone tunnel enlargement of the femoral or tibial side was observed in half of patients (6 in both sides, 5 only in the femur, and 4 only in the tibia) after ACL reconstruction was performed with a hamstring tendon fixed with an RCI screw. Female patients had a greater chance for enlargement of the femoral tunnel

  15. Patellar tendon re-rupture on the opposite end of the previous site of surgical repair

    PubMed Central

    KOH, Bryan Thean Howe; SAYAMPANATHAN, Andrew A; LEE, Keng Thiam

    2017-01-01

    We describe a rare case of a patellar tendon “re-rupture” at the opposite end of a previous proximal tendon repair. A 32-year-old male with a history of surgically repaired right proximal patellar tendon rupture presented with an acute non-traumatic right knee pain and instability during sports. Magnetic resonance imaging confirmed a complete rupture of his distal patellar tendon at the tibial tuberosity. The patellar tendon was repaired using two 5.5 mm BioCorkscrews (Arthrex) inserted into the tibial tuberosity; the tendon was stitched with the No. 2 fiberwires using Krackow technique. As the patellar tendon was degenerative, the repair was augmented with a semitendinosus tendon harvested using an open tendon stripper, leaving the distal attachment intact. At 2.6 years followup he had mild anterior knee pain, range of motion 0-130° and was able to squat. MRI scan done at followup revealed good healing of repaired patellar tendon. PMID:28566788

  16. Tendon healing in a bone tunnel. Part II: Histologic analysis after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep.

    PubMed

    Weiler, Andreas; Hoffmann, Reinhard F G; Bail, Hermann J; Rehm, Oliver; Südkamp, Norbert P

    2002-02-01

    Tendon-to-bone healing of soft-tissue grafts has been described to progress by the development of a fibrous interzone that undergoes a maturation process leading to the development of an indirect type of ligament insertion. Previous studies used extra-articular models or fixation far away from the joint line; thus, no data are available investigating tendon-to-bone healing of a soft-tissue graft fixed anatomically. Therefore, we studied the tendon-to-bone healing of the anatomic soft-tissue graft interference fit fixation in a model of anterior cruciate ligament (ACL) reconstruction in sheep. Animal study. Thirty-five mature sheep underwent ACL reconstruction with an autologous Achilles tendon split graft. Grafts were directly fixed with biodegradable poly-(D,L-lactide) interference screws. Animals were euthanized after 6, 9, 12, 24, and 52 weeks and histologic evaluations were performed. Undecalcified specimens were evaluated under normal and polarized light. Additionally, animals received a polychrome sequential labeling (tetracycline, xylenol orange, and calcein green) to determine bone growth per time under fluorescent light. Intratunnel histologic findings at 6 weeks showed a tendon-bone junction with only a partial fibrous interzone between the graft tissue and the surrounding bone. A mature intratunnel tendon-bone junction with a zone of fibrocartilage was found at 9 to 12 weeks. At the tunnel entrance site a wide regular ligamentous insertion site was seen in all specimens after 24 weeks. This insertion showed regular patterns such as the direct type of insertion of a normal ligament with a dense basophilic transition zone consisting of mineralized cartilage. A fibrous interzone between the graft tissue and the bone tunnel was only partially developed, which is in contrast to all previous studies in which nonanatomic fixation was used. Thus, it is reasonable to assume that the tendon-to-bone healing in the present study may progress partially by direct

  17. Experimental and Numerical Analysis of Screw Fixation in Anterior Cruciate Ligament Reconstruction

    NASA Astrophysics Data System (ADS)

    Chizari, Mahmoud; Wang, Bin; Snow, Martyn; Barrett, Mel

    2008-09-01

    This paper reports the results of an experimental and finite element analysis of tibial screw fixation in anterior cruciate ligament (ACL) reconstruction. The mechanical properties of the bone and tendon graft are obtained from experiments using porcine bone and bovine tendon. The results of the numerical study are compared with those from mechanical testing. Analysis shows that the model may be used to establish the optimum placement of the tunnel in anterior cruciate ligament reconstruction by predicting mechanical parameters such as stress, strain and displacement at regions in the tunnel wall.

  18. Rupture of the subscapularis tendon after shoulder arthroplasty: diagnosis, treatment, and outcome.

    PubMed

    Miller, Bruce S; Joseph, Thomas A; Noonan, Thomas J; Horan, Marilee P; Hawkins, Richard J

    2005-01-01

    The purpose of this study was to document the diagnosis, surgical treatment, and functional outcome in patients with subscapularis ruptures after shoulder arthroplasty. Prospective objective and subjective data were collected on 7 patients with symptomatic rupture of the subscapularis tendon after shoulder arthroplasty. Presenting signs and symptoms included pain, weakness in internal rotation, increased external rotation, and anterior instability. All patients were treated with surgical repair of the ruptured tendon. Four required repair augmentation with a transfer of the pectoralis major tendon. After subscapularis repair and pectoralis transfer, 2 patients continued to have anterior instability and required an additional operation to address the instability. At a mean follow-up of 2.3 years (range, 18-55 months), the mean American Shoulder and Elbow Surgeons shoulder score in this study group was 63.2. The mean patient satisfaction rating, on a 10-point scale, was 6.2. Factors associated with post-arthroplasty subscapularis ruptures included subscapularis lengthening techniques used to address internal rotation contracture and previous surgery that violated the subscapularis tendon. Symptomatic subscapularis rupture after shoulder arthroplasty introduces the need for additional surgery and a period of protected or delayed rehabilitation after arthroplasty. Although symptoms were adequately addressed with appropriate surgical treatment, decreased functional outcomes were observed.

  19. Tendon healing in a bone tunnel. Part I: Biomechanical results after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep.

    PubMed

    Weiler, Andreas; Peine, Ricarda; Pashmineh-Azar, Alireza; Abel, Clemens; Südkamp, Norbert P; Hoffmann, Reinhard F G

    2002-02-01

    Interference fit fixation of soft-tissue grafts has recently raised strong interest because it allows for anatomic graft fixation that may increase knee stability and graft isometry. Although clinical data show promising results, no data exist on how tendon healing progresses using this fixation. The purpose of the present study was to investigate anterior cruciate ligament (ACL) reconstruction biomechanically using direct tendon-to-bone interference fit fixation with biodegradable interference screws in a sheep model. Animal study. Thirty-five mature sheep underwent ACL reconstruction with an autologous Achilles tendon split graft. Grafts were directly fixed with poly-(D,L-lactide) interference screws. Animals were euthanized after 6, 9, 12, 24, and 52 weeks and standard biomechanical evaluations were performed. All grafts at time zero failed by pullout from the bone tunnel, whereas grafts at 6 and 9 weeks failed intraligamentously at the screw insertion site. At 24 and 52 weeks, grafts failed by osteocartilaginous avulsion. At 24 weeks, interference screws were macroscopically degraded. At 6 and 9 weeks tensile stress was only 6.8% and 9.6%, respectively, of the graft tissue at time zero. At 52 weeks, tensile stress of the reconstruction equaled 63.8% and 47.3% of the Achilles tendon graft at time zero and the native ACL, respectively. A complete restitution of anterior-posterior drawer displacement was found at 52 weeks compared with the time-zero reconstruction. It was found that over the whole healing period the graft fixation proved not to be the weak link of the reconstruction and that direct interference fit fixation withstands loads without motion restriction in the present animal model. The weak link during the early healing stage was the graft at its tunnel entrance site, leading to a critical decrease in mechanical properties. This finding indicates that interference fit fixation of a soft-tissue graft may additionally alter the mechanical properties of

  20. Bioresorbable pins and interference screws for fixation of hamstring tendon grafts in anterior cruciate ligament reconstruction surgery: a randomized controlled trial.

    PubMed

    Stengel, Dirk; Casper, Dirk; Bauwens, Kai; Ekkernkamp, Axel; Wich, Michael

    2009-09-01

    Biodegradable cross-pins have been shown to provide higher failure loads than do screws for fixation of hamstring tendons under laboratory conditions. To compare the clinical results of biodegradable pins (RigidFix) and interference screws (BioCryl) for fixation of hamstring grafts in arthroscopically assisted anterior cruciate ligament reconstruction. Study Design Randomized controlled trial; Level of evidence, 1. To test the hypothesis of a difference of 1.0 +/- 1.2 mm in anterior knee laxity between the two fixation options, 54 patients were randomly assigned to groups via a block randomization scheme and sealed envelopes. All patients underwent standardized hamstring graft reconstruction and had similar postoperative aftercare by an accelerated rehabilitation protocol. Measures assessed at baseline and after 1 and 2 years of follow-up included (1) the side-to-side difference in anterior laxity (KT-1000 arthrometer), (2) Short Form 36 physical and mental component scores, and (3) the International Knee Documentation Committee form scores. After 1 and 2 years, 26 and 21 patients in the BioCryl group and 28 and 24 patients in the RigidFix group were available for follow-up examination. No significant difference was noted in instrumented anterior translation between BioCryl and RigidFix fixation: 1 year, 0.11 (95% CI, -0.60 to 0.82; P = .7537); 2 years, 0.33 (95% CI, -0.43 to 1.08 mm; P = .3849). Also, there were no significant differences in the mean physical and mental component scores and International Knee Documentation Committee form scores and in overall complication and surgical revision rates. A pin dislocation was classified as the sole procedure-specific serious adverse event. Bioresorbable pins do not provide better clinical results than do resorbable interference screws for hamstring graft fixation in anterior cruciate ligament reconstruction surgery.

  1. Is quadriceps tendon a better graft choice than patellar tendon? a prospective randomized study.

    PubMed

    Lund, Bent; Nielsen, Torsten; Faunø, Peter; Christiansen, Svend Erik; Lind, Martin

    2014-05-01

    The purpose of this randomized controlled study was to compare knee stability, kneeling pain, harvest site pain, sensitivity loss, and subjective clinical outcome after primary anterior cruciate ligament (ACL) reconstruction with either bone-patellar tendon-bone (BPTB) or quadriceps tendon-bone (QTB) autografts in a noninferiority study design. From 2005 to 2009, a total of 51 patients were included in the present study. Inclusion criteria were isolated ACL injuries in adults. Twenty-five patients were randomized to BPTB grafts and 26 to QTB grafts. An independent examiner performed follow-up evaluations 1 and 2 years postoperatively. Anteroposterior knee laxity was measured with a KT-1000 arthrometer (MEDmetric, San Diego, CA). Anterior knee pain was assessed clinically and by knee-walking ability. Knee Injury and Osteoarthritis Outcome Score (KOOS) and subjective International Knee Documentation Committee (IKDC) score were used for patient-evaluated outcome. Anterior knee laxity was equal between the 2 groups with KT-1000 values of 1.1 ± 1.4 mm and 0.8 ± 1.7 mm standard deviation (SD) at follow-up in QTB and BPTB groups, respectively (P = .65), whereas positive pivot shift test results were seen less frequently (14% compared with 38%, respectively; P = .03). Anterior kneeling pain, evaluated by the knee walking ability test, was significantly less in the QTB group, with only 7% of patients grading knee walking as difficult or impossible compared with 34% in the BPTB group. At 1 and 2 years' follow-up, there was no difference between the 2 groups in subjective patient-evaluated outcome. The IKDC score was 75 ± 13 patients and 76 ± 16 SD at 1-year follow-up in QTB and BPTB groups, respectively (P = .78). At 2 years, 12 patients were lost to follow-up, resulting in 18 in the BPTB group and 21 in the QTB group. The use of the QTB graft results in less kneeling pain, graft site pain, and sensitivity loss than seen with BPTB grafts; however, similar anterior knee

  2. In vitro structural properties of braided tendon grafts.

    PubMed

    Nicklin, S; Waller, C; Walker, P; Chung, W K; Walsh, W R

    2000-01-01

    In an effort to increase strength in hamstring tendon grafts for anterior cruciate ligament reconstruction, braiding or weaving of the tendons has been suggested. The purpose of this study was to examine the biomechanical properties of two braiding techniques compared with a four-stranded tendon graft using a sheep model. Digital extensor tendons from 5 adult sheep were harvested in 28 matched pairs and randomly allocated to French plait or four-stranded weave. The grafts were tested in a hydraulic testing machine with the tendons secured in brass grips frozen with liquid carbon dioxide. The tendons were preconditioned to a distraction of 1 mm for 10 cycles followed by testing to failure at 50 mm/sec, with a data acquisition rate of 1,000 Hz. The stiffness, ultimate load to failure, and the mode of failure were recorded. All braided samples failed at the midsubstance, while the four-stranded controls failed at the grip interface. There was a significant reduction in strength and stiffness of the braided samples compared with the controls. This study demonstrated that braiding decreases the strength and stiffness of a four-stranded tendon graft by up to 54% and 85%, respectively. This finding is supported by the work of Hearle et al. (1969), who demonstrated that the decrease in strength of fiber bundles is equal to the square of the cosine of the twist angle. The twist angle in our samples was approximately 45 degrees, which equates to a decrease in strength of 50%.

  3. Incidence of Major Tendon Ruptures and Anterior Cruciate Ligament Tears in US Army Soldiers

    DTIC Science & Technology

    2007-08-01

    the effect of activity, race, age, or gender. The majority of the reports have been case studies or focused on one particular tendon and do not have...forces created by eccentric muscle activation are usually responsible for tendon failure. 1312 White et al The American Journal of Sports Medicine...Activities that maximize eccentric loading, such as repeti- tive jumping and sprinting exercises for the lower extrem- ities (bench press for the pectoralis

  4. Proteomic Differences between Male and Female Anterior Cruciate Ligament and Patellar Tendon

    PubMed Central

    Little, Dianne; Thompson, J. Will; Dubois, Laura G.; Ruch, David S.; Moseley, M. Arthur; Guilak, Farshid

    2014-01-01

    The risk of anterior cruciate ligament (ACL) injury and re-injury is greater for women than men. Among other factors, compositional differences may play a role in this differential risk. Patellar tendon (PT) autografts are commonly used during reconstruction. The aim of the study was to compare protein expression in male and female ACL and PT. We hypothesized that there would be differences in key structural components between PT and ACL, and that components of the proteome critical for response to mechanical loading and response to injury would demonstrate significant differences between male and female. Two-dimensional liquid chromatography-tandem mass spectrometry and a label-free quantitative approach was used to identify proteomic differences between male and female PT and ACL. ACL contained less type I and more type III collagen than PT. There were tissue-specific differences in expression of proteoglycans, and ACL was enriched in elastin, tenascin C and X, cartilage oligomeric matrix protein, thrombospondin 4 and periostin. Between male and female donors, alcohol dehydrogenase 1B and complement component 9 were enriched in female compared to male. Myocilin was the major protein enriched in males compared to females. Important compositional differences between PT and ACL were identified, and we identified differences in pathways related to extracellular matrix regulation, complement, apoptosis, metabolism of advanced glycation end-products and response to mechanical loading between males and females. Identification of proteomic differences between male and female PT and ACL has identified novel pathways which may lead to improved understanding of differential ACL injury and re-injury risk between males and females. PMID:24818782

  5. Ultrasound-Guided Percutaneous Tenotomy of Biceps Tendon: Technical Feasibility on Cadavers.

    PubMed

    Sconfienza, Luca Maria; Mauri, Giovanni; Messina, Carmelo; Aliprandi, Alberto; Secchi, Francesco; Sardanelli, Francesco; Randelli, Pietro Simone

    2016-10-01

    We tested the technical feasibility of ultrasound-guided percutaneous tenotomy of the long head of the biceps tendon (LHBT) in cadavers. Both shoulders of two fresh cadavers were scanned anteriorly to evaluate the extra-articular portion of the LHBT. Under ultrasound monitoring, a scalpel was advanced obliquely up to touch the superficial medial side of the LHBT, cutting it until the tendon was not visible anymore. Ultrasound evaluation was repeated after the procedure, and anatomic dissection was performed. The procedure was 100% feasible: four cuts were made to completely sever the tendon; the duration was less than 1 min. Skin incision measured 5 mm in two cases and 6 mm in two cases. Anatomic dissection confirmed complete tendon cut in all cases with proximal and distal tendon stumps very close to each other. Ultrasound-guided percutaneous LHBT tenotomy was 100% technically feasible in cadavers with a quick procedure and minimal cutaneous incision. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  6. Distribution of muscle fibre conduction velocity for representative samples of motor units in the full recruitment range of the tibialis anterior muscle.

    PubMed

    Del Vecchio, A; Negro, F; Felici, F; Farina, D

    2018-02-01

    Motor units are recruited in an orderly manner according to the size of motor neurones. Moreover, because larger motor neurones innervate fibres with larger diameters than smaller motor neurones, motor units should be recruited orderly according to their conduction velocity (MUCV). Because of technical limitations, these relations have been previously tested either indirectly or in small motor unit samples that revealed weak associations between motor unit recruitment threshold (RT) and MUCV. Here, we analyse the relation between MUCV and RT for large samples of motor units. Ten healthy volunteers completed a series of isometric ankle dorsiflexions at forces up to 70% of the maximum. Multi-channel surface electromyographic signals recorded from the tibialis anterior muscle were decomposed into single motor unit action potentials, from which the corresponding motor unit RT, MUCV and action potential amplitude were estimated. Established relations between muscle fibre diameter and CV were used to estimate the fibre size. Within individual subjects, the distributions of MUCV and fibre diameters were unimodal and did not show distinct populations. MUCV was strongly correlated with RT (mean (SD) R 2  = 0.7 (0.09), P < 0.001; 406 motor units), which supported the hypothesis that fibre diameter is associated with RT. The results provide further evidence for the relations between motor neurone and muscle fibre properties for large samples of motor units. The proposed methodology for motor unit analysis has also the potential to open new perspectives in the study of chronic and acute neuromuscular adaptations to ageing, training and pathology. © 2017 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  7. Three-dimensional study of pectoralis major muscle and tendon architecture.

    PubMed

    Fung, Lillia; Wong, Brian; Ravichandiran, Kajeandra; Agur, Anne; Rindlisbacher, Tim; Elmaraghy, Amr

    2009-05-01

    A thorough understanding of the normal structural anatomy of the pectoralis major (PM) is of paramount importance in the planning of PM tendon transfers or repairs following traumatic PM tears. However, there is little consensus regarding the complex musculotendinous architecture of the PM in the anatomic or surgical literature. The purpose of this study is to model and quantify the three-dimensional architecture of the pectoralis muscle and tendon. Eleven formalin embalmed cadaveric specimens were examined: five (2M/3F) were serially dissected, digitized, and modeled in 3D using Autodesk Maya; six (4M/2F) were dissected and photographed. The PM tendon consisted of longer anterior and shorter posterior layers that were continuous inferiorly. The muscle belly consisted of an architecturally uniform clavicular head (CH) and a segmented sternal head (SH) with 6-7 segments. The most inferior SH segment in all specimens was found to fold anteriorly forming a trough that cradled the inferior aspect of the adjacent superior segment. No twisting of either the PM muscle or tendon was noted. Within the CH, the fiber bundle lengths (FBL) were found to increase from superior to inferior, whereas the mean FBLs of SH were greatest in segments 3-5 found centrally. The mean lateral pennation angle was greater in the CH (29.4 +/- 6.9 degrees ) than in the SH (20.6 +/- 2.7 degrees ). The application of these findings could form the basis of future studies to optimize surgical planning and functional recovery of repair/reconstruction procedures.

  8. Ipsilateral free semitendinosus tendon graft with interference screw fixation for minimally invasive reconstruction of chronic tears of the Achilles tendon.

    PubMed

    Maffulli, N; Del Buono, A; Loppini, M; Denaro, V

    2014-10-01

    Minimally invasive ipsilateral semitendinosus reconstruction of large chronic tears aims to be advantageous for the patient in terms of plantar flexion recovery, anthropometric measures, fast return to daily and sport activity, is safe, with low donor site co-morbidities, low risks of wound complications and neurovascular injuries. Tendon gaps greater than 6 cm and in cases of revision surgery (rerupture). Diabetes, vascular diseases, previous anterior cruciate ligament (ACL) reconstruction using ipsilateral semitendinosus tendon graft. The semitendinosus tendon is harvested through an incision in the medial aspect of the popliteal fossa, and the proximal stump is exposed and mobilized through an incision performed 2 cm proximal and medial to the palpable tendon gap. We repeat the same steps distally, approaching the distal stump of the tendon through a 2.5 cm longitudinal incision made 2 cm distal and just anterior to the lateral margin of the distal stump. Through the distal incision, we expose the Kager's space and the postero-superior corner of the osteotomized calcaneum. We drill a bone tunnel into the calcaneum from dorsal to plantar using a cannulated headed reamer. The semitendinosus tendon graft is passed into the proximal stump through a medial-to-lateral small incision, its two ends are moved distally, and finally it is pulled down and shuttled through the bone tunnel. The construct is fixed to the calcaneum using an interference screw. Immobilization in a below the knee plaster cast with the foot in plantar flexion for 2 weeks, weight bearing on the metatarsal heads as tolerated, use elbow crutches, and keep the knee flexed. At 2 weeks, plaster removed, and rehabilitative exercises started, walker cast allowed. Between 2008 and 2010, the procedure was performed on 28 consecutive patients (21 men and 7 women, median age 46 years). At the 2-year follow-up, average ATRS scores significantly improved (p < 0.0001) compared to average preoperative

  9. Dynamic restraint capacity of the hamstring muscles has important functional implications after anterior cruciate ligament injury and anterior cruciate ligament reconstruction.

    PubMed

    Bryant, Adam L; Creaby, Mark W; Newton, Robert U; Steele, Julie R

    2008-12-01

    The purpose of this study was to investigate the relation between knee functionality of anterior cruciate ligament deficient (ACLD) and anterior cruciate ligament reconstruction (ACLR) patients and hamstring antagonist torque generated during resisted knee extension. Cross-sectional. Laboratory based. Male ACLD subjects (n=10) (18-35 y) and 27 matched males who had undergone ACLR (14 patella tendon [PT] grafts and 13 combined semitendinosus/gracilis tendon grafts). Not applicable. Knee functionality was rated (0- to 100-point scale) by using the Cincinnati Knee Rating System. Using electromyography data from the semitendinosus (ST) and biceps femoris muscles, we created a mathematical model to estimate the opposing torque generated by the hamstrings during isokinetic knee extension in 10 degrees intervals from 80 degrees to 10 degrees knee flexion. Pearson product-moment correlations revealed that more functional ACLD subjects generated significantly (P<.05) higher hamstring antagonist torque throughout knee extension. In contrast, more functional PT subjects produced significantly lower hamstring antagonist torque at 80 degrees to 70 degrees knee flexion, whereas no significant associations were found between hamstring antagonist torque and knee functionality for the ST/gracilis tendon subjects. An increased hamstring antagonist torque generated by the more functional ACLD subjects, reflective of increased hamstring contractile force, is thought to represent a protective mechanism to compensate for mechanical instability. The restoration of anterior knee stability through ACLR negates the need for augmented hamstring antagonist torque.

  10. Do Australian Football players have sensitive groins? Players with current groin pain exhibit mechanical hyperalgesia of the adductor tendon.

    PubMed

    Drew, Michael K; Lovell, Gregory; Palsson, Thorvaldur S; Chiarelli, Pauline E; Osmotherly, Peter G

    2016-10-01

    This is the first study to evaluate the mechanical sensitivity, clinical classifications and prevalence of groin pain in Australian football players. Case-control. Professional (n=66) and semi-professional (n=9) Australian football players with and without current or previous groin injuries were recruited. Diagnoses were mapped to the Doha Agreement taxonomy. Point and career prevalence of groin pain was calculated. Pressure pain thresholds (PPTs) were assessed at regional and distant sites using handheld pressure algometry across four sites bilaterally (adductor longus tendon, pubic bone, rectus femoris, tibialis anterior muscle). To assess the relationship between current groin pain and fixed effects of hyperalgesia of each site and a history of groin pain, a mixed-effect logistic regression model was utilised. Receiver Operator Characteristic (ROC) curve were determined for the model. Point prevalence of groin pain in the preseason was 21.9% with a career prevalence of 44.8%. Adductor-related groin pain was the most prevalent classification in the pre-season period. Hyperalgesia was observed in the adductor longus tendon site in athletes with current groin pain (OR=16.27, 95% CI 1.86 to 142.02). The ROC area under the curve of the regression model was fair (AUC=0.76, 95% CI 0.54 to 0.83). Prevalence data indicates that groin pain is a larger issue than published incidence rates imply. Adductor-related groin pain is the most common diagnosis in pre-season in this population. This study has shown that hyperalgesia exists in Australian football players experiencing groin pain indicating the value of assessing mechanical pain sensitivity as a component of the clinical assessment. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  11. Tendon transfer fixation: comparing a tendon to tendon technique vs. bioabsorbable interference-fit screw fixation.

    PubMed

    Sabonghy, Eric Peter; Wood, Robert Michael; Ambrose, Catherine Glauber; McGarvey, William Christopher; Clanton, Thomas Oscar

    2003-03-01

    Tendon transfer techniques in the foot and ankle are used for tendon ruptures, deformities, and instabilities. This fresh cadaver study compares the tendon fixation strength in 10 paired specimens by performing a tendon to tendon fixation technique or using 7 x 20-25 mm bioabsorbable interference-fit screw tendon fixation technique. Load at failure of the tendon to tendon fixation method averaged 279N (Standard Deviation 81N) and the bioabsorbable screw 148N (Standard Deviation 72N) [p = 0.0008]. Bioabsorbable interference-fit screws in these specimens show decreased fixation strength relative to the traditional fixation technique. However, the mean bioabsorbable screw fixation strength of 148N provides physiologic strength at the tendon-bone interface.

  12. Can local corticosteroid injection in the retrocalcaneal bursa lead to rupture of the Achilles tendon and the medial head of the gastrocnemius muscle?

    PubMed

    Turmo-Garuz, A; Rodas, G; Balius, R; Til, L; Miguel-Perez, M; Pedret, C; Del Buono, A; Maffulli, N

    2014-08-01

    The purpose of the study is to explain the cause-effect relationship in three patients who reported combined ruptures of the Achilles tendon and the gastrosoleus complex 6 months after they had received corticosteroids injections for the management of retrocalcaneal bursitis. Three cryopreserved cadavers (three men, three left legs) were examined to assess the anatomic connection between the retrocalcaneal bursa and the Achilles tendon (distal and anterior fibers). Blue triptan medium contrast was injected. An unexpected connection between the retrocalcaneal bursa and the anterior fibers of the Achilles tendon was found in all instances. Local corticosteroid injection of the retrocalcaneal bursa may help the symptoms of retrocalcanear bursitis, but pose a risk of Achilles tendon rupture. This risk-benefit has to be taken into account when corticosteroid injections are prescribed to professional and high-level athletes.

  13. Tendon injuries

    PubMed Central

    Wu, Fan; Nerlich, Michael; Docheva, Denitsa

    2017-01-01

    Tendons connect muscles to bones, ensuring joint movement. With advanced age, tendons become more prone to degeneration followed by injuries. Tendon repair often requires lengthy periods of rehabilitation, especially in elderly patients. Existing medical and surgical treatments often fail to regain full tendon function. The development of novel treatment methods has been hampered due to limited understanding of basic tendon biology. Recently, it was discovered that tendons, similar to other mesenchymal tissues, contain tendon stem/progenitor cells (TSPCs) which possess the common stem cell properties. The current strategies for enhancing tendon repair consist mainly of applying stem cells, growth factors, natural and artificial biomaterials alone or in combination. In this review, we summarise the basic biology of tendon tissues and provide an update on the latest repair proposals for tendon tears. Cite this article: EFORT Open Rev 2017;2:332-342. DOI: 10.1302/2058-5241.2.160075 PMID:28828182

  14. Presence of Bacteria in Spontaneous Achilles Tendon Ruptures.

    PubMed

    Rolf, Christer G; Fu, Sai-Chuen; Hopkins, Chelsea; Luan, Ju; Ip, Margaret; Yung, Shu-Hang; Friman, Göran; Qin, Ling; Chan, Kai-Ming

    2017-07-01

    The structural pathology of Achilles tendon (AT) ruptures resembles tendinopathy, but the causes remain unknown. Recently, a number of diseases were found to be attributed to bacterial infections, resulting in low-grade inflammation and progressive matrix disturbance. The authors speculate that spontaneous AT ruptures may also be influenced by the presence of bacteria. Bacteria are present in ruptured ATs but not in healthy tendons. Cross-sectional study; Level of evidence, 3. Patients with spontaneous AT ruptures and patients undergoing anterior cruciate ligament (ACL) reconstruction were recruited for this study. During AT surgical repair, excised tendinopathic tissue was collected, and healthy tendon samples were obtained as controls from hamstring tendon grafts used in ACL reconstruction. Half of every sample was reserved for DNA extraction and the other half for histology. Polymerase chain reaction (PCR) was conducted using 16S rRNA gene universal primers, and the PCR products were sequenced for the identification of bacterial species. A histological examination was performed to compare tendinopathic changes in the case and control samples. Five of 20 AT rupture samples were positive for the presence of bacterial DNA, while none of the 23 hamstring tendon samples were positive. Sterile operating and experimental conditions and tests on samples, controlling for harvesting and processing procedures, ruled out the chance of postoperative bacterial contamination. The species identified predominantly belonged to the Staphylococcus genus. AT rupture samples exhibited histopathological features characteristic of tendinopathy, and most healthy hamstring tendon samples displayed normal tendon features. There were no apparent differences in histopathology between the bacterial DNA-positive and bacterial DNA-negative AT rupture samples. The authors have demonstrated the presence of bacterial DNA in ruptured AT samples. It may suggest the potential involvement of bacteria

  15. Mechanoactive Scaffold Induces Tendon Remodeling and Expression of Fibrocartilage Markers

    PubMed Central

    Spalazzi, Jeffrey P.; Vyner, Moira C.; Jacobs, Matthew T.; Moffat, Kristen L.

    2008-01-01

    Biological fixation of soft tissue-based grafts for anterior cruciate ligament (ACL) reconstruction poses a major clinical challenge. The ACL integrates with subchondral bone through a fibrocartilage enthesis, which serves to minimize stress concentrations and enables load transfer between two distinct tissue types. Functional integration thus requires the reestablishment of this fibrocartilage interface on reconstructed ACL grafts. We designed and characterized a novel mechanoactive scaffold based on a composite of poly-α-hydroxyester nanofibers and sintered microspheres; we then used the scaffold to test the hypothesis that scaffold-induced compression of tendon grafts would result in matrix remodeling and the expression of fibrocartilage interface-related markers. Histology coupled with confocal microscopy and biochemical assays were used to evaluate the effects of scaffold-induced compression on tendon matrix collagen distribution, cellularity, proteoglycan content, and gene expression over a 2-week period. Scaffold contraction resulted in over 15% compression of the patellar tendon graft and upregulated the expression of fibrocartilage-related markers such as Type II collagen, aggrecan, and transforming growth factor-β3 (TGF-β3). Additionally, proteoglycan content was higher in the compressed tendon group after 1 day. The data suggest the potential of a mechanoactive scaffold to promote the formation of an anatomic fibrocartilage enthesis on tendon-based ACL reconstruction grafts. PMID:18512112

  16. Mechanoactive scaffold induces tendon remodeling and expression of fibrocartilage markers.

    PubMed

    Spalazzi, Jeffrey P; Vyner, Moira C; Jacobs, Matthew T; Moffat, Kristen L; Lu, Helen H

    2008-08-01

    Biological fixation of soft tissue-based grafts for anterior cruciate ligament (ACL) reconstruction poses a major clinical challenge. The ACL integrates with subchondral bone through a fibrocartilage enthesis, which serves to minimize stress concentrations and enables load transfer between two distinct tissue types. Functional integration thus requires the reestablishment of this fibrocartilage interface on reconstructed ACL grafts. We designed and characterized a novel mechanoactive scaffold based on a composite of poly-alpha-hydroxyester nanofibers and sintered microspheres; we then used the scaffold to test the hypothesis that scaffold-induced compression of tendon grafts would result in matrix remodeling and the expression of fibrocartilage interface-related markers. Histology coupled with confocal microscopy and biochemical assays were used to evaluate the effects of scaffold-induced compression on tendon matrix collagen distribution, cellularity, proteoglycan content, and gene expression over a 2-week period. Scaffold contraction resulted in over 15% compression of the patellar tendon graft and upregulated the expression of fibrocartilage-related markers such as Type II collagen, aggrecan, and transforming growth factor-beta3 (TGF-beta3). Additionally, proteoglycan content was higher in the compressed tendon group after 1 day. The data suggest the potential of a mechanoactive scaffold to promote the formation of an anatomic fibrocartilage enthesis on tendon-based ACL reconstruction grafts.

  17. Effects of braiding on tensile properties of four-strand human hamstring tendon grafts.

    PubMed

    Millett, Peter J; Miller, Bruce S; Close, Matthew; Sterett, William I; Walsh, William; Hawkins, Richard J

    2003-01-01

    Anterior cruciate ligament reconstruction is commonly performed with autogenous hamstring tendon grafts. To ascertain the effects of braiding on ultimate tensile strength and stiffness of hamstring tendon graft. Controlled laboratory study. Sixteen fresh-frozen semitendinosus and gracilis tendons were harvested from eight matched (right and left) human cadaveric specimens. Both sets of hamstring tendons from each matched pair were doubled, creating a four-strand graft. Grafts were then randomized so that one graft from each matched pair was braided and the other remained unbraided. The diameter of each graft construct was recorded. Grafts were tested to failure on a materials testing machine. There were no significant differences in cross-sectional area before or after braiding. Fifteen of 16 tendons failed midsubstance; 1 failed at the lower clamp. Braiding reduced the initial tensile strength and stiffness of human hamstring tendon grafts in this study by 35.0% and 45.8%, respectively. Braiding may place the collagen fibers in a suboptimal orientation for loading that results in a weaker graft. We do not recommend the use of braiding if the strongest, stiffest initial graft is desired.

  18. EVALUATION OF THE RESULTS OF ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION USING FLEXOR TENDONS AND RIGID GUIDE TRANSVERSE SCREW

    PubMed Central

    de Castro, Renato Luiz Bevilacqua; Acras, Sandor Dosa

    2015-01-01

    Objective: The aim of this study was to analyze the results of ACL (anterior cruciate ligament) reconstruction using quadruple flexor tendons as grafts, with ligament fixation in the femur using a rigid guide transverse screw and in the tibia, using a cancellous screw with a fixing washer. Methods: 173 knees (166 from males and seven from females) that had undergone surgery with ACL reconstruction using this technique between December 2002 and February 2007 were evaluated. The mean age was 30 years (from 13 to 56 years), and the mean follow-up time was 30 months (6-55 months). We divided the knees into three groups, which were assessed using the Lysholm scale: Group A with six months of follow-up; Group B with 12 months of follow-up; and Group C with 24 months of follow-up. Results: We evaluated the results, and groups A, B and C received 94, 95 and 95 points respectively on the Lysholm scale. Conclusions: The surgical technique proved to be safe and easy to perform, with good results and a low complication rate. Also, its results were maintained throughout the study period of 24 months. PMID:27027002

  19. Anterior stability of the reverse shoulder arthroplasty depending on implant configuration and rotator cuff condition.

    PubMed

    Pastor, Marc-Frederic; Kraemer, Manuel; Wellmann, Mathias; Hurschler, Christof; Smith, Tomas

    2016-11-01

    The aim of this study was to investigate the stabilizing influence of the rotator cuff as well as the importance of glenosphere and onlay configuration on the anterior stability of the reverse total shoulder replacement (RTSR). A reverse total shoulder replacement was implanted into eight human cadaveric shoulders, and biomechanical testing was performed under three conditions: after implantation of the RTSR, after additional dissection of the subscapularis tendon, and after additional dissection of the infraspinatus and teres minor tendon. Testing was performed in 30° of abduction and three rotational positions: 30° internal rotation, neutral rotation, and 30° external rotation. Furthermore, the 38-mm and 42-mm glenospheres were tested in combination with a standard and a high-mobility humeral onlay. A gradually increased force was applied to the glenohumeral joint in anterior direction until the RTSR dislocated. The 42-mm glenosphere showed superior stability compared with the 38-mm glenosphere. The standard humeral onlay required significantly higher anterior dislocation forces than the more shallow high-mobility onlay. External rotation was the most stable position. Furthermore, isolated detachment of the subscapularis and combined dissection of the infraspinatus, teres minor, and subscapularis tendon increased anterior instability. This study showed superior stability with the 42-mm glenosphere and the more conforming standard onlay. External rotation was the most stable position. Detachment of the subscapularis as well as dissection of the complete rotator cuff decreased anterior stability.

  20. Characterising the proximal patellar tendon attachment and its relationship to skeletal maturity in adolescent ballet dancers

    PubMed Central

    Rudavsky, Aliza; Cook, Jillianne; Magnusson, Stig Peter; Kjaer, Michael; Docking, Sean

    2017-01-01

    Summary Background It is unknown how and when the proximal attachment of the patellar tendon matures; puberty may be key in ensuring normal tendon formation. The aim of this study was to investigate the features of the proximal patellar tendon attachment at different stages of skeletal maturity, to help gain an understanding of how and when the tendon attachment matures. Methods Sixty adolescent elite ballet students (ages 11–18) and eight mature adults participated. Peak height velocity (PHV) estimated skeletal maturity. Ultrasound tissue characterisation (UTC) scan was taken of the left knee and analysed for stability of echopattern. An image-based grading scale for greyscale ultrasound was developed to describe the tendon appearance. Anterior-posterior thickness was measured at the inferior pole of the patella, 1 and 2 centimetres distally. Outcomes were compared with skeletal maturity. Results Mid-portion patellar tendon thickness increased with skeletal maturity (p=0.001 at 1 cm and p=0.007 at 2 cm). There was more variance in structural appearance (greyscale classification and UTC echopattern) in pre and peri-PHV participants. Tendon attachment one-year post PHV appeared similar to mature tendons. Conclusions Early adolescence was associated with highly variable tendon appearance, whereas the tendon appeared mature after PHV. Adolescence may be a critical time for the formation of normal tendon attachment. Level of evidence IIb individual cohort study. PMID:29264342

  1. Intra and inter-session reliability of rapid Transcranial Magnetic Stimulation stimulus-response curves of tibialis anterior muscle in healthy older adults

    PubMed Central

    Colombo, Vera Maria; van de Ruit, Mark; Grey, Michael J.; Monticone, Marco; Ferriero, Giorgio; Pedrocchi, Alessandra; Ferrigno, Giancarlo; Ferrante, Simona

    2017-01-01

    Objective The clinical use of Transcranial Magnetic Stimulation (TMS) as a technique to assess corticospinal excitability is limited by the time for data acquisition and the measurement variability. This study aimed at evaluating the reliability of Stimulus-Response (SR) curves acquired with a recently proposed rapid protocol on tibialis anterior muscle of healthy older adults. Methods Twenty-four neurologically-intact adults (age:55–75 years) were recruited for this test-retest study. During each session, six SR curves, 3 at rest and 3 during isometric muscle contractions at 5% of maximum voluntary contraction (MVC), were acquired. Motor Evoked Potentials (MEPs) were normalized to the maximum peripherally evoked response; the coil position and orientation were monitored with an optical tracking system. Intra- and inter-session reliability of motor threshold (MT), area under the curve (AURC), MEPmax, stimulation intensity at which the MEP is mid-way between MEPmax and MEPmin (I50), slope in I50, MEP latency, and silent period (SP) were assessed in terms of Standard Error of Measurement (SEM), relative SEM, Minimum Detectable Change (MDC), and Intraclass Correlation Coefficient (ICC). Results The relative SEM was ≤10% for MT, I50, latency and SP both at rest and 5%MVC, while it ranged between 11% and 37% for AURC, MEPmax, and slope. MDC values were overall quite large; e.g., MT required a change of 12%MSO at rest and 10%MSO at 5%MVC to be considered a real change. Inter-sessions ICC were >0.6 for all measures but slope at rest and MEPmax and latency at 5%MVC. Conclusions Measures derived from SR curves acquired in <4 minutes are affected by similar measurement errors to those found with long-lasting protocols, suggesting that the rapid method is at least as reliable as the traditional methods. As specifically designed to include older adults, this study provides normative data for future studies involving older neurological patients (e.g. stroke survivors). PMID

  2. Intra and inter-session reliability of rapid Transcranial Magnetic Stimulation stimulus-response curves of tibialis anterior muscle in healthy older adults.

    PubMed

    Peri, Elisabetta; Ambrosini, Emilia; Colombo, Vera Maria; van de Ruit, Mark; Grey, Michael J; Monticone, Marco; Ferriero, Giorgio; Pedrocchi, Alessandra; Ferrigno, Giancarlo; Ferrante, Simona

    2017-01-01

    The clinical use of Transcranial Magnetic Stimulation (TMS) as a technique to assess corticospinal excitability is limited by the time for data acquisition and the measurement variability. This study aimed at evaluating the reliability of Stimulus-Response (SR) curves acquired with a recently proposed rapid protocol on tibialis anterior muscle of healthy older adults. Twenty-four neurologically-intact adults (age:55-75 years) were recruited for this test-retest study. During each session, six SR curves, 3 at rest and 3 during isometric muscle contractions at 5% of maximum voluntary contraction (MVC), were acquired. Motor Evoked Potentials (MEPs) were normalized to the maximum peripherally evoked response; the coil position and orientation were monitored with an optical tracking system. Intra- and inter-session reliability of motor threshold (MT), area under the curve (AURC), MEPmax, stimulation intensity at which the MEP is mid-way between MEPmax and MEPmin (I50), slope in I50, MEP latency, and silent period (SP) were assessed in terms of Standard Error of Measurement (SEM), relative SEM, Minimum Detectable Change (MDC), and Intraclass Correlation Coefficient (ICC). The relative SEM was ≤10% for MT, I50, latency and SP both at rest and 5%MVC, while it ranged between 11% and 37% for AURC, MEPmax, and slope. MDC values were overall quite large; e.g., MT required a change of 12%MSO at rest and 10%MSO at 5%MVC to be considered a real change. Inter-sessions ICC were >0.6 for all measures but slope at rest and MEPmax and latency at 5%MVC. Measures derived from SR curves acquired in <4 minutes are affected by similar measurement errors to those found with long-lasting protocols, suggesting that the rapid method is at least as reliable as the traditional methods. As specifically designed to include older adults, this study provides normative data for future studies involving older neurological patients (e.g. stroke survivors).

  3. Repair of distal biceps tendon rupture with the Biotenodesis screw.

    PubMed

    Khan, W; Agarwal, M; Funk, L

    2004-04-01

    Distal biceps tendon ruptures are uncommon injuries with only around 300 cases reported in the literature. Current management tends to favour anatomical reinsertion of the tendon into the radial tuberosity, especially in young and active individuals. These injuries are commonly repaired using either a single anterior incision with suture anchors or the Boyd-Anderson dual incision technique. We report the use of a bioabsorbable interference screw for the repair of distal biceps tendon rupture using a minimal incision technique. In this technique the avulsed tendon and a bioabsorbable screw are secured in a drill hole on the radial tuberosity using whip stitch and fibre wire sutures according to Biotenodesis system guidelines. The technique described requires minimal volar dissection that is associated with a reduced number of synostosis and posterior interosseous nerve injuries. The bioabsorbable interference screw has all the advantages of being biodegradable and has been shown to have greater pullout strength than suture anchors. It is also a reasonable alternative to titanium screws in terms of primary fixation strength. The strong fixation provided allows early active motion and return to previous activities as seen in our case.

  4. Biomechanical comparison between the rectangular-tunnel and the round-tunnel anterior cruciate ligament reconstruction procedures with a bone-patellar tendon-bone graft.

    PubMed

    Suzuki, Tomoyuki; Shino, Konsei; Otsubo, Hidenori; Suzuki, Daisuke; Mae, Tatsuo; Fujimiya, Mineko; Yamashita, Toshihiko; Fujie, Hiromichi

    2014-10-01

    The purpose of this study was to evaluate the effectiveness of 2 anterior cruciate ligament (ACL) reconstruction techniques using a bone-patellar tendon-bone (BPTB) graft with femoral tunnel, either a rectangular tunnel (RET) or a round tunnel (ROT). For experiment 1, nine fresh-frozen human cadaveric knees were tested with a robotic/universal force-moment sensor system to determine the initial optimal tension: the amount of graft tension at 15° of flexion most closely resembling the anterior laxity of a normal knee. The value was estimated by repeatedly measuring anterior laxity when 100 N of anteroposterior drawer load was applied to the knees at 30° of flexion after RET ACL or ROT ACL reconstruction. For experiment 2, six fresh-frozen human cadaveric knees were selected. On the basis of the initial tension determined in experiment 1, RET ACL reconstruction was conducted with the graft tensioned to 10 N, followed by ROT ACL reconstruction on the same knee at 40 N of initial tension, and the biomechanical efficacy of the 2 methods was compared. For experiment 1, the mean laxity match tension at 15° of flexion was 8.6 ± 4.8 N and 34.8 ± 9.2 N for RET- and ROT-reconstructed knees, respectively. For experiment 2, both RET and ROT ACL reconstructions were successful in controlling anterior tibial translation under anterior tibial loads, with the graft initially tensioned to 10 N in the former and to 40 N in the latter. However, the greater tensioning in ROT reconstruction led to proximal, posterior, and lateral displacement of the tibia along with its external and valgus rotation. The RET ACL-reconstructed knee more closely resembled the normal knee in biomechanical behavior. Although ROT reconstruction successfully controlled anterior translation with greater initial tensioning to the graft, the normal positional relation between the tibia and femur was impaired. Rectangular femoral ACL fixation constructs and grafts may prove more efficacious at

  5. Does Additional Biceps Augmentation Improve Rotator Cuff Healing and Clinical Outcomes in Anterior L-Shaped Rotator Cuff Tears? Clinical Comparisons With Arthroscopic Partial Repair.

    PubMed

    Jeon, Yoon Sang; Lee, Juyeob; Kim, Rag Gyu; Ko, Young-Won; Shin, Sang-Jin

    2017-11-01

    The repair of anterior L-shaped tears is usually difficult because of the lack of anterior rotator cuff tendon to cover the footprint. The biceps tendon is usually exposed from the retracted anterolateral corner of the torn tendon and can be easily used to augment rotator cuff repair. Hypothesis/Purpose: This study compared the clinical outcomes of the biceps augmentation technique with those of partial tendon repair for the arthroscopic treatment of large anterior L-shaped rotator cuff tears to evaluate the role of additional biceps augmentation in tendon healing. We hypothesized that the biceps augmentation technique would lead to a lower rotator cuff tendon retear rate and provide satisfactory functional outcomes. Cohort study; Level of evidence, 3. This study included 64 patients with anterior L-shaped rotator cuff tears who underwent arthroscopic repair. Patients were divided into 2 groups: group A (31 patients) underwent repair of an anterior L-shaped tear combined with biceps augmentation, and group B (33 patients) had a partially repaired tendon whose footprint was exposed after repair without undue tension on the retracted tendon. Clinical evaluations were performed using the American Shoulder and Elbow Surgeons (ASES) score, Constant score, muscle strength, visual analog scale for pain, and patient satisfaction. Magnetic resonance imaging (MRI) was performed for tendon integrity at 6 months postoperatively. The mean period of follow-up was 29.1 ± 3.5 months (range, 24-40 months). The mean ASES and Constant scores significantly improved from 52.8 ± 10.6 and 43.2 ± 9.9 preoperatively to 88.2 ± 6.9 and 86.8 ± 6.2 at final follow-up in group A ( P < .001) and from 53.0 ± 11.8 and 44.3 ± 11.3 preoperatively to 87.4 ± 7.2 and 87.9 ± 7.3 at final follow-up in group B ( P < .001). Overall muscle strength (given as % of the other side's strength) significantly increased from preoperatively to final follow-up in group A (forward flexion [FF]: 62.0 ± 8

  6. Comparison of Gait Aspects According to FES Stimulation Position Applied to Stroke Patients

    PubMed Central

    Mun, Byeong-mu; Kim, Tae-ho; Lee, Jin-hwan; Lim, Jin-youg; Seo, Dong-kwon; Lee, Dong-jin

    2014-01-01

    [Purpose] This study sought to identify the gait aspects according to the FES stimulation position in stroke patients during gait training. [Subjects and Methods] To perform gait analysis, ten stroke patients were grouped based on 4 types of gait conditions: gait without FES stimulation (non-FES), gait with FES stimulation on the tibialis anterior (Ta), gait with FES stimulation on the tibialis anterior and quadriceps (TaQ), and gait with FES stimulation on the tibialis anterior and gluteus medius (TaGm). [Results] Based on repeated measures analysis of variance of measurements of gait aspects comprised of gait speed, gait cycle, and step length according to the FES stimulation position, the FES stimulation significantly affected gait aspects. [Conclusion] In conclusion, stimulating the tibialis anterior and quadriceps and stimulating the tibialis anterior and gluteus medius are much more effective than stimulating only the tibialis anterior during gait training in stroke patients using FES. PMID:24764634

  7. Patellar tendon healing with platelet-rich plasma: a prospective randomized controlled trial.

    PubMed

    de Almeida, Adriano Marques; Demange, Marco Kawamura; Sobrado, Marcel Faraco; Rodrigues, Marcelo Bordalo; Pedrinelli, André; Hernandez, Arnaldo José

    2012-06-01

    The patellar tendon has limited ability to heal after harvesting its central third. Platelet-rich plasma (PRP) could improve patellar tendon healing. Adding PRP to the patellar tendon harvest site would improve donor site healing and improve clinical outcome at 6 months after anterior cruciate ligament (ACL) reconstruction with a patellar tendon graft. Randomized controlled trial; Level of evidence, 1. Twenty-seven patients were randomly divided to receive (n = 12) or not receive (n = 15) PRP in the patellar tendon harvest site during ACL reconstruction. The primary outcome was magnetic resonance imaging (MRI) assessment of patellar tendon healing (gap area) after 6 months. Secondary outcomes were questionnaires and isokinetic testing of ACL reconstruction with a patellar tendon graft comparing both groups. Patellar tendon gap area was significantly smaller in the PRP group (4.9 ± 5.3 mm(2); 95% confidence interval [CI], 1.1-8.8) than in the control group (9.4 ± 4.4 mm(2); 95% CI, 6.6-12.2; P = .046). Visual analog scale score for pain was lower in the PRP group immediately postoperatively (3.8 ± 1.0; 95% CI, 3.18-4.49) than in the control group (5.1 ± 1.4; 95% CI, 4.24-5.90; P = .02). There were no differences after 6 months in questionnaire and isokinetic testing results comparing both groups. We showed that PRP had a positive effect on patellar tendon harvest site healing on MRI after 6 months and also reduced pain in the immediate postoperative period. Questionnaire and isokinetic testing results were not different between the groups at 6 months.

  8. Utility of an allograft tendon for scoliosis correction via the costo-transverse foreman.

    PubMed

    Sun, Dong; McCarthy, Michael; Dooley, Adam C; Ramakrishnaiah, Raghu H; Shelton, R Shane; McLaren, Sandra G; Skinner, Robert A; Suva, Larry J; McCarthy, Richard E

    2017-01-01

    Current convex tethering techniques for treatment of scoliosis have centered on anterior convex staples or polypropylene tethers. We hypothesized that an allograft tendon tether inserted via the costo-transverse foramen would correct an established spinal deformity. In the pilot study, six 8-week-old pigs underwent allograft tendon tethering via the costo-transverse foreman or sham to test the strength of the transplanted tendon to retard spine growth. After 4 months, spinal deformity in three planes was induced in all animals with allograft tendons. In the treatment study, the allograft tendon tether was used to treat established scoliosis in 11 8-week-old pigs (spinal deformity > 50°). Once the deformity was observed (4 months) animals were assigned to either no treatment group or allograft tendon tether group and progression assessed by monthly radiographs. At final follow-up, coronal Cobb angle and maximum vertebral axial rotation of the treatment group was significantly smaller than the non-treatment group, whereas sagittal kyphosis of the treatment group was significantly larger than the non-treatment group. In sum, a significant correction was achieved using a unilateral allograft tendon spinal tether, suggesting that an allograft tendon tethering approach may represent a novel fusion-less procedure to correct idiopathic scoliosis. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:183-192, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  9. Outcomes and complications following graft reconstruction for anterior sternoclavicular joint instability.

    PubMed

    Willinger, Lukas; Schanda, Jakob; Herbst, Elmar; Imhoff, Andreas B; Martetschläger, Frank

    2016-12-01

    Publications describing tendon graft reconstruction for anterior sternoclavicular joint (SCJ) instability are rare and usually refer to small patient numbers. The aim of this study was to systematically review the literature regarding outcomes and complications following tendon graft reconstruction techniques for anterior SCJ instability. An online database was systematically searched to identify studies on graft reconstruction for anterior SCJ instability. Reported outcome scores were graded as excellent, good, fair and poor to summarize the study results. All reported complications were recorded. Five articles with a total of 80 patients met the inclusion criteria. Reported outcomes were excellent in 10 %, good in 89 % and fair in 1 %. Recurrent instability was found in 10 % of the patients, and 5 % underwent revision surgery due to persistent impairment of shoulder function related to SCJ instability or osteoarthritis. Surgical stabilization techniques for the SCJ using autologous tendon grafts have shown to be safe and reliable and make better patients' pain situation and shoulder function. However, a certain amount of impairment might persist, which needs to be discussed with patients. Severe complications were rare and revision rates were as low as 5 %. Therefore, graft reconstruction techniques should be considered for patients with chronic anterior SCJ instability after a course of failed conservative treatment. This study is valuable for clinicians in daily clinical practice when dealing with this difficult-to-treat pathology and can help surgeons to better predict the clinical outcomes and complications following SCJ graft reconstruction. It should, however, not lead to underestimation of the potential risks of the procedure. Systematic review, Level IV.

  10. Anatomic ACL reconstruction: does the platelet-rich plasma accelerate tendon healing?

    PubMed

    Silva, Alcindo; Sampaio, Ricardo

    2009-06-01

    Recently, the use of hamstring tendons in anterior cruciate ligament repair has been increasing. However, tendon-to-bone healing occurs slowly, which can be a problem to an early return to sport activities. The use of growth factors from platelets seems to improve tissue healing. We enrolled 40 patients in a prospective study that were submitted to an anatomic reconstruction of the anterior cruciate ligament. Patients were sequentially enrolled into four groups: group A without platelet-rich plasma (PRP); group B with PRP in femoral tunnels at the end of surgery; group C with PRP in femoral tunnels at the end of surgery and intra-articular at 2- and 4 weeks after surgery; group D with PRP activated with thrombin in the femoral tunnels. All patients underwent magnetic resonance imaging of the knee 3 months after surgery to evaluate the signal intensity of the fibrous interzone (FIZ) in the femoral tunnels. We did not find any difference among the groups when comparing the signal intensity of the FIZ on magnetic resonance imaging.

  11. Sterilization with electron beam irradiation influences the biomechanical properties and the early remodeling of tendon allografts for reconstruction of the anterior cruciate ligament (ACL).

    PubMed

    Schmidt, Tanja; Hoburg, Arnd; Broziat, Christine; Smith, Mark D; Gohs, Uwe; Pruss, Axel; Scheffler, Sven

    2012-08-01

    Although allografts for anterior cruciate ligament (ACL) replacement have shown advantages compared to autografts, their use is limited due to the risk of disease transmission and the limitations of available sterilization methods. Gamma sterilization has shown detrimental effects on graft properties at the high doses required for sufficient pathogen inactivation. In our previous in vitro study on human patellar tendon allografts, Electron beam (Ebeam) irradiation showed less detrimental effects compared to gamma sterilization (Hoburg et al. in Am J Sports Med 38(6):1134-1140, 2010). To investigate the biological healing and restoration of the mechanical properties of a 34 kGy Ebeam treated tendon allograft twenty-four sheep underwent ACL replacement with either a 34 kGy Ebeam treated allograft or a non-sterilized fresh frozen allograft. Biomechanical testing of stiffness, ultimate failure load and AP-laxity as well as histological analysis to investigate cell, vessel and myofibroblast-density were performed after 6 and 12 weeks. Native sheep ACL and hamstring tendons (HAT, each n = 9) served as controls. The results of a previous study analyzing the remodeling of fresh frozen allografts (n = 12) and autografts (Auto, n = 18) with the same study design were also included in the analysis. Statistics were performed using Mann-Whitney U test followed by Bonferroni-Holm correction. Results showed significantly decreased biomechanical properties during the early remodeling period in Ebeam treated grafts and this was accompanied with an increased remodeling activity. There was no recovery of biomechanical function from 6 to 12 weeks in this group in contrast to the results observed in fresh frozen allografts and autografts. Therefore, high dose Ebeam irradiation investigated in this paper cannot be recommended for soft tissue allograft sterilization.

  12. Material costs of anterior cruciate ligament reconstruction with hamstring tendons by two different techniques.

    PubMed

    Cournapeau, J; Klouche, S; Hardy, P

    2013-04-01

    In France, approximately 36,000 anterior cruciate ligament (ACL) reconstruction surgical procedures are performed every year. Technical progress, in particular arthroscopy, has made surgery more precise, but more expensive. In a context of healthcare cost containment, the increase in the cost of technology must be compared to the improved outcome for the patients. The main aim of this study was to determine all material costs related to ACL reconstruction using hamstring tendons. This study also compared the material costs between the two arthroscopic techniques: standard or "all-inside". A retrospective study of material costs was performed in 2011. With the standard technique, the tibial tunnel was drilled from outside to inside, while with the all-inside technique two tunnels were drilled from inside to outside. All of the material used from the first swab to the final bandage was reported. It was classified into three categories: reusable arthroscopy material, disposable arthroscopic material, and disposable surgical supplies. The costs were those of our supplier in 2011 (Arthrex™) and based on Public Hospitals of Paris (AP-HP) public contract tariffs. Standard ligament reconstruction was less expensive than the all-inside technique: 791.59€ versus 931.06€ excluding taxes (hors taxes [HT]), respectively. The largest percentage of expenses was allocated to disposable material use (81 and 84%). Possible avenues of savings are limited: all the material used was necessary. To control costs, correct use and good maintenance of instruments are the most important elements. Level IV. Economic and decision analyses, retrospective study. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  13. Transcription factor EGR1 directs tendon differentiation and promotes tendon repair

    PubMed Central

    Guerquin, Marie-Justine; Charvet, Benjamin; Nourissat, Geoffroy; Havis, Emmanuelle; Ronsin, Olivier; Bonnin, Marie-Ange; Ruggiu, Mathilde; Olivera-Martinez, Isabel; Robert, Nicolas; Lu, Yinhui; Kadler, Karl E.; Baumberger, Tristan; Doursounian, Levon; Berenbaum, Francis; Duprez, Delphine

    2013-01-01

    Tendon formation and repair rely on specific combinations of transcription factors, growth factors, and mechanical parameters that regulate the production and spatial organization of type I collagen. Here, we investigated the function of the zinc finger transcription factor EGR1 in tendon formation, healing, and repair using rodent animal models and mesenchymal stem cells (MSCs). Adult tendons of Egr1–/– mice displayed a deficiency in the expression of tendon genes, including Scx, Col1a1, and Col1a2, and were mechanically weaker compared with their WT littermates. EGR1 was recruited to the Col1a1 and Col2a1 promoters in postnatal mouse tendons in vivo. Egr1 was required for the normal gene response following tendon injury in a mouse model of Achilles tendon healing. Forced Egr1 expression programmed MSCs toward the tendon lineage and promoted the formation of in vitro–engineered tendons from MSCs. The application of EGR1-producing MSCs increased the formation of tendon-like tissues in a rat model of Achilles tendon injury. We provide evidence that the ability of EGR1 to promote tendon differentiation is partially mediated by TGF-β2. This study demonstrates EGR1 involvement in adult tendon formation, healing, and repair and identifies Egr1 as a putative target in tendon repair strategies. PMID:23863709

  14. The effect of platelet-derived growth factors on knee stability after anterior cruciate ligament reconstruction: a prospective randomized clinical study.

    PubMed

    Vogrin, Matjaz; Rupreht, Mitja; Crnjac, Anton; Dinevski, Dejan; Krajnc, Zmago; Recnik, Gregor

    2010-05-01

    Arthroscopic reconstruction is a standard surgical procedure in cases of symptomatic knee instability due to rupture of the anterior cruciate ligament. Bone-tendon-bone and hamstring tendon grafts are both in use for anterior cruciate ligament reconstruction. There are no significant differences between the two types of graft in relation to function scores, but there is a difference in anteroposterior stability when measured on the KT-2000 arthrometer: knee joints after reconstruction with bone-tendon-bone autografts are more stable than those reconstructed with hamstring tendon autografts. To improve knee stability after anterior cruciate ligament reconstruction with a hamstring graft and use of platelet-derived growth factors. Platelet-leukocyte gel was produced from platelet-leukocyte-rich plasma prepared from a unit of whole blood in an autologous platelet separator. The gel was applied locally, after hamstring graft placement. Fifty patients were included in the study: 25 in the platelet gel group, 25 in a control group. We evaluated anteroposterior knee stability with the KT-2000 arthrometer before surgery and at 3 and 6 months after surgery. Patients treated with the gel demonstrated significantly better anteroposterior knee stability than patients in the control group. The calculated improvements in knee stability at 6 months were 1.3 +/- 1.8 mm in the control group and 3.1 +/- 2.5 mm in the platelet gel group (P = 0.011). Platelet-leukocyte gel, applied locally, can improve knee stability in surgery for reconstruction of the anterior cruciate ligament.

  15. Effect of Achilles tendon loading on plantar fascia tension in the standing foot.

    PubMed

    Cheung, Jason Tak-Man; Zhang, Ming; An, Kai-Nan

    2006-02-01

    The plantar fascia, which is one of the major arch-supporting structures of the human foot, sustains high tensions during weight-bearing. A positive correlation between Achilles tendon loading and plantar fascia tension has been reported. Excessive stretching and tightness of the Achilles tendon are thought to be the risk factors of plantar fasciitis but their biomechanical effects on the plantar fascia have not been fully addressed. A three-dimensional finite element model of the human foot and ankle, incorporating geometrical and material nonlinearity, was employed to investigate the loading response of the plantar fascia in the standing foot with different magnitudes of Achilles tendon loading. With the total ground reaction forces of one foot maintained at 350 N to represent half body weight, an increase in Achilles tendon load from (0-700 N) resulted in a general increase in total force and peak plantar pressure at the forefoot of up to about 250%. There was a lateral and anterior shift of the centre of pressure and a reduction in the arch height with an increasing Achilles tendon load as a result of the plantar flexion moment on the calcaneus. From the finite element predictions of simulated balanced standing, Achilles tendon forces of 75% of the total weight on the foot (350 N) were found to provide the closest match of the measured centre of pressure of the subject during balanced standing. Both the weight on the foot and Achilles tendon loading resulted in an increase in tension of the plantar fascia with the latter showing a two-times larger straining effect. Increasing tension on the Achilles tendon is coupled with an increasing strain on the plantar fascia. Overstretching of the Achilles tendon resulting from intense muscle contraction and passive stretching of tight Achilles tendon are plausible mechanical factors for overstraining of the plantar fascia.

  16. Short medial approach harvesting of hamstring tendons.

    PubMed

    Lanternier, H; de Cussac, J B; Collet, T

    2016-04-01

    Harvesting the hamstring tendons for anterior cruciate ligament reconstruction is not straightforward to perform or to teach: the incision is small, the work-space is narrow and the surgeon's tactile feedback using the stripper is difficult to explain to juniors. The purpose of this short note is to describe a reliable means of harvesting the semitendinosus, gracilis or both. Patient and tourniquet positioning, instrumentation and landmarks are detailed; then the 6 steps (speed-bump 1, speed-bump 2, bubble, hook, expansions, stripper) are explained. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  17. INTEGRITY OF THE SUBSCAPULARIS TENDON AFTER OPEN SURGERY FOR THE TREATMENT OF ANTERIOR SHOULDER INSTABILITY: A CLINICAL AND RADIOLOGICAL EVALUATION

    PubMed Central

    Lech, Osvandré; Piluski, Paulo; Tambani, Renato; Castro, Nero; Pimentel, Gilnei

    2015-01-01

    Objective: To evaluate the integrity of the subscapularis tendon by strength, function and magnetic resonance imaging after deltopectoralis access for anterior shoulder instability. Methods: 20 patients with anterior shoulder instability have been evaluated. Minimum follow-up was 12 months, with a mean of 40 months. Only male patients were included, with a mean of age of 29 years (20 − 42 years). The patients have been submitted to physical examinations of mobility, muscular strength, Belly Test and Gerber Test. The isokinetic strength in internal and external rotation, in angular speeds of 600/s and 1800/s, for both shoulders was measured using a dynamometer. In 15 patients magnetic resonance imaging (MRI) was carried out on both shoulders for evaluating the thickness, cross-sectional area and atrophy of the subscapularis muscle. Results: A significant difference was found between torque peaks at the speed of 600/s for internal (p=0.036) and external (p=0.008) rotation. However, at 1800/s the opposite happens (internal rotation: p=0.133; external rotation: p=0.393). Subscapularis muscle thickness and area are significantly smaller than the normal side, with a deficit of 19% and 23%, respectively. According to Rowe and UCLA scores, we find excellent and good results for the majority of patients, with a mean of 88 and 31.6 points, respectively. Conclusion: Despite of the good functional results, open surgery can limit strength and reduce the thickness and the cross-sectional area of subscapularis muscle. However, the best results were found in the patients who had the dominant side operated. PMID:27004190

  18. INTEGRITY OF THE SUBSCAPULARIS TENDON AFTER OPEN SURGERY FOR THE TREATMENT OF ANTERIOR SHOULDER INSTABILITY: A CLINICAL AND RADIOLOGICAL EVALUATION.

    PubMed

    Lech, Osvandré; Piluski, Paulo; Tambani, Renato; Castro, Nero; Pimentel, Gilnei

    2009-01-01

    To evaluate the integrity of the subscapularis tendon by strength, function and magnetic resonance imaging after deltopectoralis access for anterior shoulder instability. 20 patients with anterior shoulder instability have been evaluated. Minimum follow-up was 12 months, with a mean of 40 months. Only male patients were included, with a mean of age of 29 years (20 - 42 years). The patients have been submitted to physical examinations of mobility, muscular strength, Belly Test and Gerber Test. The isokinetic strength in internal and external rotation, in angular speeds of 60(0)/s and 180(0)/s, for both shoulders was measured using a dynamometer. In 15 patients magnetic resonance imaging (MRI) was carried out on both shoulders for evaluating the thickness, cross-sectional area and atrophy of the subscapularis muscle. A significant difference was found between torque peaks at the speed of 60(0)/s for internal (p=0.036) and external (p=0.008) rotation. However, at 180(0)/s the opposite happens (internal rotation: p=0.133; external rotation: p=0.393). Subscapularis muscle thickness and area are significantly smaller than the normal side, with a deficit of 19% and 23%, respectively. According to Rowe and UCLA scores, we find excellent and good results for the majority of patients, with a mean of 88 and 31.6 points, respectively. Despite of the good functional results, open surgery can limit strength and reduce the thickness and the cross-sectional area of subscapularis muscle. However, the best results were found in the patients who had the dominant side operated.

  19. The effect of in situ freezing on rabbit patellar tendon. A histologic, biochemical, and biomechanical analysis

    NASA Technical Reports Server (NTRS)

    Graf, B. K.; Fujisaki, K.; Vanderby, R. Jr; Vailas, A. C.

    1992-01-01

    Cell necrosis has been well documented as one of the many changes that occur in autogenous tendon when it is used to reconstruct the anterior cruciate ligament. The purpose of this experiment was to isolate cell necrosis as a variable and study its effect on the patellar tendon. To accomplish this, both knees of 25 New Zealand White rabbits were operated on. In one knee, a 5-mm wide band of patellar tendon was subjected to two rapid freeze-thaw cycles, while the other knee underwent sham surgery. Histologic evaluation showed a zone of necrosis at 2 and 4 weeks with cellular repopulation complete at 8 weeks. patellar tendon cross-sectional area was 0.118 cm2 at 8 weeks for the frozen specimens compared to 0.102 cm2 for the sham-operated controls. This difference was significant at the P = 0.025 level. Mechanical testing at 4 and 8 weeks revealed no significant changes in tendon length, maximum load, or stiffness. The collagen content was also unchanged at both 4 and 8 weeks.

  20. Bone morphogenetic protein 7 (BMP-7) influences tendon-bone integration in vitro.

    PubMed

    Schwarting, Tim; Lechler, Philipp; Struewer, Johannes; Ambrock, Marius; Frangen, Thomas Manfred; Ruchholtz, Steffen; Ziring, Ewgeni; Frink, Michael

    2015-01-01

    Successful graft ingrowth following reconstruction of the anterior cruciate ligament is governed by complex biological processes at the tendon-bone interface. The aim of this study was to investigate in an in vitro study the effects of bone morphogenetic protein 7 (BMP-7) on tendon-bone integration. To study the biological effects of BMP-7 on the process of tendon-bone-integration, two independent in vitro models were used. The first model involved the mono- and coculture of bovine tendon specimens and primary bovine osteoblasts with and without BMP-7 exposure. The second model comprised the mono- and coculture of primary bovine osteoblasts and fibroblasts. Alkaline phosphatase (ALP), lactate dehydrogenase (LDH), lactate and osteocalcin (OCN) were analyzed by ELISA. Histological analysis and electron microscopy of the tendon specimens were performed. In both models, positive effects of BMP-7 on ALP enzyme activity were observed (p<0.001). Additionally, similar results were noted for LDH activity and lactate concentration. BMP-7 stimulation led to a significant increase in OCN expression. Whereas the effects of BMP-7 on tendon monoculture peaked during an early phase of the experiment (p<0.001), the cocultures showed a maximal increase during the later stages (p<0.001). The histological analysis showed a stimulating effect of BMP-7 on extracellular matrix formation. Organized ossification zones and calcium carbonate-like structures were only observed in the BMP-stimulated cell cultures. This study showed the positive effects of BMP-7 on the biological process of tendon-bone integration in vitro. Histological signs of improved mineralization were paralleled by increased rates of osteoblast-specific protein levels in primary bovine osteoblasts and fibroblasts. Our findings indicated a role for BMP-7 as an adjuvant therapeutic agent in the treatment of ligamentous injuries, and they emphasized the importance of the transdifferentiation process of tendinous fibroblasts

  1. Is Quadriceps Tendon Autograft a Better Choice Than Hamstring Autograft for Anterior Cruciate Ligament Reconstruction? A Comparative Study With a Mean Follow-up of 3.6 Years.

    PubMed

    Cavaignac, Etienne; Coulin, Benoit; Tscholl, Philippe; Nik Mohd Fatmy, Nik; Duthon, Victoria; Menetrey, Jacques

    2017-05-01

    The quadriceps tendon (QT) autograft is known as an effective graft for anterior cruciate ligament (ACL) reconstruction and shows a similar functional outcome to the bone-patellar tendon-bone (BPTB) in randomized controlled trials, with a lesser incidence of complications. Up until now, only 2 studies have compared QT to hamstring tendon (HT) autograft. The functional outcomes of the QT technique are at least as good as those of the HT technique, with the same morbidity. Cohort study; Level of evidence, 3. Ninety-five patients underwent isolated ACL reconstruction between January 1 and December 31, 2012. Fifty underwent ACL reconstruction with the QT and 45 with the HT. The same surgical technique, fixation method, and postoperative protocol were used in both groups. The following parameters were evaluated: surgical revisions, functional outcome (Lysholm, Knee injury and Osteoarthritis Outcome Score [KOOS], Tegner, subjective International Knee Documentation Committee), joint stability (KT-1000, Lachman, pivot shift), anterior knee pain (Shelbourne-Trumper score), and isokinetic strength. Descriptive statistics are presented for these variables using the Student t test. Eighty-six patients (45 QT, 41 HT) were reviewed with a mean follow-up of 3.6 ± 0.4 years; minimum follow-up was 3 years. There were 4 reoperations in the QT group (including 1 ACL revision) and 3 in the HT group (including 2 ACL revisions) ( P > .05). The Lysholm (89 ± 6.9 vs 83.1 ± 5.3), KOOS Symptoms (90 ± 11.2 vs 81 ± 10.3), and KOOS Sport (82 ± 11.3 vs 67 ± 12.4) scores were significantly better in the QT group than in the HT group. In terms of stability, the mean side-to-side difference was 1.1 ± 0.9 mm for the QT group and 3.1 ± 1.3 mm for the HT group based on KT-1000 measurements ( P < .005). The negative Lachman component was higher in the QT group than in the HT group (90% vs 46%, P < .005). There was a trend for the negative pivot-shift component to be higher in the QT group

  2. Decellularized Tendon Extracellular Matrix—A Valuable Approach for Tendon Reconstruction?

    PubMed Central

    Schulze-Tanzil, Gundula; Al-Sadi, Onays; Ertel, Wolfgang; Lohan, Anke

    2012-01-01

    Tendon healing is generally a time-consuming process and often leads to a functionally altered reparative tissue. Using degradable scaffolds for tendon reconstruction still remains a compromise in view of the required high mechanical strength of tendons. Regenerative approaches based on natural decellularized allo- or xenogenic tendon extracellular matrix (ECM) have recently started to attract interest. This ECM combines the advantages of its intrinsic mechanical competence with that of providing tenogenic stimuli for immigrating cells mediated, for example, by the growth factors and other mediators entrapped within the natural ECM. A major restriction for their therapeutic application is the mainly cell-associated immunogenicity of xenogenic or allogenic tissues and, in the case of allogenic tissues, also the risk of disease transmission. A survey of approaches for tendon reconstruction using cell-free tendon ECM is presented here, whereby the problems associated with the decellularization procedures, the success of various recellularization strategies, and the applicable cell types will be thoroughly discussed. Encouraging in vivo results using cell-free ECM, as, for instance, in rabbit models, have already been reported. However, in comparison to native tendon, cells remain mostly inhomogeneously distributed in the reseeded ECM and do not align. Hence, future work should focus on the optimization of tendon ECM decellularization and recolonization strategies to restore tendon functionality. PMID:24710540

  3. Management of acute Achilles tendon rupture with tendon-bundle technique

    PubMed Central

    Li, Chun-Guang; Li, Bing

    2017-01-01

    Objective *These authors contributed equally to this work.To explore tendon-bundle technique for treating Achilles tendon rupture with no defects. Methods Patients with full unilateral Achilles tendon rupture with no defects were included. The Achilles tendon medial edge surgical repair approach was used, revealing horsetail-like rupture bundles. Tendon bundles were anatomically realigned and repaired end-to-end using 5-0 sutures. Patients were followed-up for 1 year, and assessed for differences between the repaired versus healthy limb. Results Out of 24 patients (18 male, 6 female; aged 19–56 years) at 1 year following surgery, mean American Orthopaedic Foot and Ankle Society score was 92.4 ± 5.9; mean differences between the surgically repaired versus contralateral side in dorsiflexion and plantarflexion angle were 3.5 ± 2.3° and 5.6 ± 3.2°, respectively; mean difference in calf circumference between the two sides was 0.9 ± 0.5 cm; and mean increase in Achilles tendon width versus the healthy side was 0.8 ± 0.2 cm. By 1 year post-surgery, there were no significant between-side differences in dorsiflexion and plantarflexion angle, or calf circumference. Conclusions Tendon-bundle surgery resulted in good ankle function restoration and low complication rates. Tendon-bundle surgery may reduce blood supply destruction and maximally preserve Achilles tendon length, and may be effective for treating Achilles tendon rupture with no defects. PMID:28222622

  4. [Ultrastructural observation of tendonization of artificial tendon 109HH in rabbit].

    PubMed

    Liu, L; Cao, Q; Xiao, H

    1995-09-01

    Ten New Zealand rabbits were divided into 5 groups at random. Calcaneal tendons were cut bilaterally, then atificial tendon 109HH was used to connect the two ends of the cut tendon. Ultrastructural changes of control group and experimental groups at 2, 6, 12, 28 weeks after section were observed. The results showed that fibroblast proliferated and a lot of ribosome and RER appeared in plasm during 2 approximately 6 weeks, indicating artificial tendon caused fibroblast proliferation. During this period, fibroblast over synthesized collagenous protein and the synthesis of collagenous fibers peaked. During 12-28 weeks, the number of fibroblasts and the synthesis of collagenous protein decreased. Finally, fibroblasts became inactive tendon cells. With the formation of new tendons, the artificial tendens were degradated and absorbed, and disappeared after 12 weeks. The new tendon fibers became thicker and had the correct direction through reconstruction. The structure and function of new tendons could be restored to be consistent with normal values.

  5. [Rheumatic tendon pathologies].

    PubMed

    Thomas, M; Jordan, M

    2014-11-01

    Rheumatoid arthritis is found in approximately 2 % of the total population in Europe and the peak incidence of the disease is during the fourth and fifth decades of life. In approximately 15 % the first symptoms of the disease occur at the level of the foot and ankle. If the early stage-dependent therapy with pharmaceuticals fails isolated surgery of the tendons (e.g. tenosynovectomy) and reconstructive surgery including the tendons (e.g. tendon transfer and tendon readaptation) are performed to keep the patient mobile. The aim of this article is to give an overview of the most commonly used interventions in the reconstruction of tendons in rheumatism patients and the corresponding indications. The conservative therapy options for rheumatic foot and ankle alterations with a special emphasis on tendon pathologies have a well-established importance and are also presented. A selective literature search was carried out for therapeutic options of rheumatic tendon pathologies. If possible attempts should be made to preserve functional qualities using tenosynovectomy, tendon sutures or tendon transfer operations. If joints are already destroyed or dislocated, tendon operations should be carried out only as combined interventions with arthrodesis, endoprostheses or resection arthroplasty. The time window in which these interventions are possible should not be missed. Orthotic devices, bandages or even orthopedic shoes provide external support and splinting but do not represent a causal therapy.

  6. Double-layer versus single-layer bone-patellar tendon-bone anterior cruciate ligament reconstruction: a prospective randomized study with 3-year follow-up.

    PubMed

    Mei, Xiaoliang; Zhang, Zhenxiang; Yang, Jingwen

    2016-12-01

    To evaluate the clinical results of a randomized controlled trial of single-layer versus double-layer bone-patellar tendon-bone (BPTB) anterior cruciate ligament (ACL) reconstruction. Fifty-eight subjects who underwent primary ACL reconstruction with a BPTB allograft were prospectively randomized into two groups: single-layer reconstruction (n = 31) and double-layer reconstruction (n = 27). The following evaluation methods were used: clinical examination, KT-1000 arthrometer measurement, muscle strength, Tegner activity score, Lysholm score, subjective rating scale regarding patient satisfaction and sports performance level, graft retear, contralateral ACL tear, and additional meniscus surgery. Forty-eight subjects (24 in single-layer group and 24 in double-layer group) who were followed up for 3 years were evaluated. Preoperatively, there were no differences between the groups. At 3-year follow-up, the Lachman and pivot-shift test results were better in the double-layer group (P = 0.019 and P < 0.0001, respectively). KT measurements were better in the double-layer group (mean 2.9 versus 1.5 mm; P = 0.0025). The Tegner score was also better in the double-layer group (P = 0.024). There were no significant differences in range of motion, muscle strength, Lysholm score, subjective rating scale, graft retear, and secondary meniscal tear. In ACL reconstruction, double-layer BPTB reconstruction was significantly better than single-layer reconstruction regarding anterior and rotational stability at 3-year follow-up. The results of KT measurements and the Lachman and pivot-shift tests were significantly better in the double-layer group, whereas there was no difference in the anterior drawer test results. The Tegner score was also better in the double-layer group; however, there were no differences in the other subjective findings.

  7. Biologics for tendon repair☆

    PubMed Central

    Docheva, Denitsa; Müller, Sebastian A.; Majewski, Martin; Evans, Christopher H.

    2015-01-01

    Tendon injuries are common and present a clinical challenge to orthopedic surgery mainly because these injuries often respond poorly to treatment and require prolonged rehabilitation. Therapeutic options used to repair ruptured tendons have consisted of suture, autografts, allografts, and synthetic prostheses. To date, none of these alternatives has provided a successful long-term solution, and often the restored tendons do not recover their complete strength and functionality. Unfortunately, our understanding of tendon biology lags far behind that of other musculoskeletal tissues, thus impeding the development of new treatment options for tendon conditions. Hence, in this review, after introducing the clinical significance of tendon diseases and the present understanding of tendon biology, we describe and critically assess the current strategies for enhancing tendon repair by biological means. These consist mainly of applying growth factors, stem cells, natural biomaterials and genes, alone or in combination, to the site of tendon damage. A deeper understanding of how tendon tissue and cells operate, combined with practical applications of modern molecular and cellular tools could provide the long awaited breakthrough in designing effective tendon-specific therapeutics and overall improvement of tendon disease management. PMID:25446135

  8. Patellar Sleeve Fracture With Ossification of the Patellar Tendon.

    PubMed

    Damrow, Derek S; Van Valin, Scott E

    2017-03-01

    Patellar sleeve fractures make up greater than 50% of all patellar fractures. They are essentially only seen in the pediatric population because of the thick periosteum and the distal patellar pole apophysis in this group. These fractures can lead to complications if not treated appropriately and in a timely fashion. Complications of missed or untreated patellar sleeve fractures include patella alta, anterior knee pain, and quadriceps atrophy. These can all result in severe limitations in activity. The authors describe a case of a 16-year-old boy who sustained a patellar sleeve fracture 3 years prior to presentation. On presentation, he had patella alta, diminished strength, 5° of extensor lag, and radiographs that revealed bone formation along the patellar tendon. Despite this, he was able to maintain a high level of activity. This case report explores how the patient could have maintained a high level of activity despite having a patellar sleeve fracture. Also, because of the delayed presentation, the patella was ossified and the quadriceps was retracted, which led to a novel approach to reconstructing his distal extensor mechanism. This approach included a V-Y advancement of the quadriceps tendon and patellar tendon reconstruction using the patient's hamstring tendon (semitendinosus). This technique, combined with physical therapy postoperatively, resulted in his return to varsity high school soccer. To the best of the authors' knowledge, this technique has not been reported for this rare condition. [Orthopedics. 2017; 40(2):e357-e359.]. Copyright 2016, SLACK Incorporated.

  9. Achilles tendon: US examination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fornage, B.D.

    Real-time ultrasonography (US) using linear-array probes and a stand-off pad as a ''waterpath'' was performed to evaluate the Achilles tendon in 67 patients (including 24 athletes) believed to have acute or chronic traumatic or inflammatory pathologic conditions. Tendons in 23 patients appeared normal on US scans. The 44 abnormal tendons comprised five complete and four partial ruptures, seven instances of postoperative change, and 28 cases of tendonitis. US depiction of the inner structure of the tendon resulted in the diagnosis of focal abnormalities, including partial ruptures, nodules, and calcifications. Tendonitis was characterized by enlargement and decreased echogenicity of the tendon.more » The normal US appearance of the Achilles tendon is described.« less

  10. Phenytoin accelerates tendon healing in a rat model of Achilles tendon rupture.

    PubMed

    Hajipour, B; Navali, A M; Mohammad, S Ali; Mousavi, G; Akbari, M Gahvechi; Miyandoab, T Maleki; Roshangar, L; Saleh, B Mohammadi; Kermani, T Asvadi; Laleh, F Moutab; Ghabili, M

    2016-01-01

    Tendons are vulnerable to various types of acute or chronic injures. Different methods have been investigated to achieve better healing. Phenytoin is a drug which could stimulate fibroblasts to produce collagen. This experimental study was performed to assess the effect of phenytoin on tendon healing in a rat model of tendon rupture. Thirty healthy rats were divided into 3 groups, 1) Sham group; 2) Tendon rupture; 3) Tendon rupture+phenytoin (100 mg/kg intraperitoneally) for 21 days. On 21st day after tendon injury, the rats were anesthetized and tendon tissue was sampled for studying by light and electron microscopy. Qualitative and quantitative microscopic comparisons of the repair tissues of both groups were made on the 21st day. The results obtained from light and electron microscopy studies showed that tendon tissue healing was significantly better in phenytoin group compared to the control group (p < 0.05). Systemic administration of phenytoin may have a positive effect on tendon healing by increasing fibroblast quantity, fibrillar collagen synthesis, vascularity, and suppressing inflammation (Tab. 2, Ref. 25).

  11. Informing Stem Cell-Based Tendon Tissue Engineering Approaches with Embryonic Tendon Development.

    PubMed

    Okech, William; Kuo, Catherine K

    Adult tendons fail to regenerate normal tissue after injury, and instead form dysfunctional scar tissue with abnormal mechanical properties. Surgical repair with grafts is the current standard to treat injuries, but faces significant limitations including pain and high rates of re-injury. To address this, we aim to regenerate new, normal tendons to replace dysfunctional tendons. A common approach to tendon tissue engineering is to design scaffolds and bioreactors based on adult tendon properties that can direct adult stem cell tenogenesis. Despite significant progress, advances have been limited due, in part, to a need for markers and potent induction cues. Our goal is to develop novel tendon tissue engineering approaches informed by embryonic tendon development. We are characterizing structure-property relationships of embryonic tendon to identify design parameters for three-dimensional scaffolds and bioreactor mechanical loading systems to direct adult stem cell tenogenesis. We will review studies in which we quantified changes in the mechanical and biochemical properties of tendon during embryonic development and elucidated specific mechanisms of functional property elaboration. We then examined the effects of these mechanical and biochemical factors on embryonic tendon cell behavior. Using custom-designed bioreactors, we also examined the effects of dynamic mechanical loading and growth factor treatment on embryonic tendon cells. Our findings have established cues to induce tenogenesis as well as metrics to evaluate differentiation. We finish by discussing how we have evaluated the tenogenic differentiation potential of adult stem cells by comparing their responses to that of embryonic tendon cells in these culture systems.

  12. Latissimus Dorsi Tendon Transfer for Irreparable Rotator Cuff Tears: A Modified Technique Using Arthroscopy

    PubMed Central

    Villacis, Diego; Merriman, Jarrad; Wong, Karlton; Rick Hatch, George F.

    2013-01-01

    Latissimus dorsi transfer is a well-established method for the treatment of posterosuperior massive irreparable rotator cuff tears. We propose using an arthroscopically assisted technique that avoids insult to the deltoid. With the patient in the lateral decubitus position, an L-shaped incision is made along the anterior belly of the latissimus muscle and then along the posterior axillary line. The latissimus and teres major are identified and separated. The tendon insertion of the latissimus is isolated, and a FiberWire traction suture (Arthrex, Naples, FL) is placed, facilitating dissection of the muscle to the thoracodorsal neurovascular pedicle and subsequent mobilization. The interval deep to the deltoid and superficial to the teres minor is developed into a subdeltoid tunnel for arthroscopic tendon transfer. The latissimus tendon is then transferred and stabilized arthroscopically to the lateral aspect of the infraspinatus and supraspinatus footprints by multiple suture anchors. PMID:23767006

  13. Simultaneous bilateral distal biceps tendon ruptures repaired using an endobutton technique: a case report.

    PubMed

    Dacambra, Mark P; Walker, Richard Ea; Hildebrand, Kevin A

    2013-08-23

    The simultaneous rupture of both distal biceps tendons is a rare clinical entity that is difficult to treat and can have poor outcomes. A variety of treatment and rehabilitation options exist and have been reported for single sided and staged bilateral repairs, but none have described an approach for acute bilateral ruptures. Repairing distal biceps tendon ruptures using a single anterior incision and a cortical suspensory button technique has become increasingly popular in recent years. We present a report of our surgical approach using an endobutton technique and rehabilitation algorithm for this unusual injury pattern. A 43-year-old Caucasian man presented with acute onset bilateral elbow pain while lifting a large sheet of drywall off the ground. He initially felt a 'pop' on the right and almost immediately felt another on the left after having to quickly shift the weight. He was unable to continue working and sought medical attention. His pain was predominantly in his bilateral antecubital fossae and he had significant swelling and ecchymoses. His clinical examination demonstrated no palpable tendon, a retracted biceps muscle belly, and clear supination weakness. Magnetic resonance imaging was performed and showed bilateral distal biceps tendon ruptures with retraction on both sides. After discussion with our patient, we decided that both sides would be repaired using a single anterior incision with endobutton fixation, first his right followed by his left six weeks later. Overall, our patient did very well and had returned to full manual work by our last follow-up at 30 months. Although he was never able to return to competitive recreational hockey and was left with mild lateral antebrachial cutaneous nerve dysesthesias on his right, he felt he was at 85% of his premorbid level of function. We describe what we believe to be, to the best of our knowledge, the first case of simultaneous bilateral distal biceps tendon ruptures successfully treated with a single

  14. Simultaneous bilateral distal biceps tendon ruptures repaired using an endobutton technique: a case report

    PubMed Central

    2013-01-01

    Introduction The simultaneous rupture of both distal biceps tendons is a rare clinical entity that is difficult to treat and can have poor outcomes. A variety of treatment and rehabilitation options exist and have been reported for single sided and staged bilateral repairs, but none have described an approach for acute bilateral ruptures. Repairing distal biceps tendon ruptures using a single anterior incision and a cortical suspensory button technique has become increasingly popular in recent years. We present a report of our surgical approach using an endobutton technique and rehabilitation algorithm for this unusual injury pattern. Case presentation A 43-year-old Caucasian man presented with acute onset bilateral elbow pain while lifting a large sheet of drywall off the ground. He initially felt a ‘pop’ on the right and almost immediately felt another on the left after having to quickly shift the weight. He was unable to continue working and sought medical attention. His pain was predominantly in his bilateral antecubital fossae and he had significant swelling and ecchymoses. His clinical examination demonstrated no palpable tendon, a retracted biceps muscle belly, and clear supination weakness. Magnetic resonance imaging was performed and showed bilateral distal biceps tendon ruptures with retraction on both sides. After discussion with our patient, we decided that both sides would be repaired using a single anterior incision with endobutton fixation, first his right followed by his left six weeks later. Conclusion Overall, our patient did very well and had returned to full manual work by our last follow-up at 30 months. Although he was never able to return to competitive recreational hockey and was left with mild lateral antebrachial cutaneous nerve dysesthesias on his right, he felt he was at 85% of his premorbid level of function. We describe what we believe to be, to the best of our knowledge, the first case of simultaneous bilateral distal biceps

  15. Modified tendon stripper for obtaining palmaris longus tendon graft.

    PubMed

    Aköz, T; Altintaş, H; Civelek, B

    1999-04-01

    Tendon graft harvesting is a challenging part of hand surgery. It is not only a time-consuming procedure but also carries the potential complications associated with it. Various alternatives for this procedure are presented in the literature to overcome these difficulties. In this paper, we are presenting a series of cases in which a newly modified tendon stripper was used for tendon graft harvesting.

  16. A case of adult-onset reducing body myopathy presenting a novel clinical feature, asymmetrical involvement of the sternocleidomastoid and trapezius muscles.

    PubMed

    Fujii, Takayuki; Hayashi, Shintaro; Kawamura, Nobutoshi; Higuchi, Masa-Aki; Tsugawa, Jun; Ohyagi, Yasumasa; Hayashi, Yukiko K; Nishino, Ichizo; Kira, Jun-Ichi

    2014-08-15

    We herein report a 32-year-old woman with adult-onset reducing body myopathy (RBM) who had a mutation in the four-and-a-half LIM domain 1 gene (FHL1) and showed a marked asymmetrical involvement of sternocleidomastoid and trapezius muscles. At 30 years of age she noticed bilateral foot drop, and over the next two years developed difficulty raising her right arm. At 32 years of age she was admitted to our hospital for a diagnostic evaluation. Neurological examination showed moderate weakness and atrophy of her right sternocleidomastoid muscle, right trapezius muscle, and bilateral upper proximal muscles. There were severe weakness and atrophy of her bilateral tibialis anterior muscles. Her deep tendon reflexes were hypoactive in her upper extremities. Her serum creatine kinase level was mildly increased. Muscle biopsy specimens from the left tibialis anterior muscle revealed marked variation in fiber size, some necrotic or regenerating fibers, and reducing bodies. Gene analysis of FHL1 demonstrated a mutation: a heterozygous missense mutation of c.377G>A (p. C126T) in FHL1. Compared with previous adult-onset RBM cases harboring mutations in FHL1, our case was characterized by asymmetrical atrophy of the sternocleidomastoid and trapezius muscles. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Fos Promotes Early Stage Teno-Lineage Differentiation of Tendon Stem/Progenitor Cells in Tendon.

    PubMed

    Chen, Jialin; Zhang, Erchen; Zhang, Wei; Liu, Zeyu; Lu, Ping; Zhu, Ting; Yin, Zi; Backman, Ludvig J; Liu, Huanhuan; Chen, Xiao; Ouyang, Hongwei

    2017-11-01

    Stem cells have been widely used in tendon tissue engineering. The lack of refined and controlled differentiation strategy hampers the tendon repair and regeneration. This study aimed to find new effective differentiation factors for stepwise tenogenic differentiation. By microarray screening, the transcript factor Fos was found to be expressed in significantly higher amounts in postnatal Achilles tendon tissue derived from 1 day as compared with 7-days-old rats. It was further confirmed that expression of Fos decreased with time in postnatal rat Achilles tendon, which was accompanied with the decreased expression of multiply tendon markers. The expression of Fos also declined during regular in vitro cell culture, which corresponded to the loss of tendon phenotype. In a cell-sheet and a three-dimensional cell culture model, the expression of Fos was upregulated as compared with in regular cell culture, together with the recovery of tendon phenotype. In addition, significant higher expression of tendon markers was found in Fos-overexpressed tendon stem/progenitor cells (TSPCs), and Fos knock-down gave opposite results. In situ rat tendon repair experiments found more normal tendon-like tissue formed and higher tendon markers expression at 4 weeks postimplantation of Fos-overexpressed TSPCs derived nonscaffold engineering tendon (cell-sheet), as compared with the control group. This study identifies Fos as a new marker and functional driver in the early stage teno-lineage differentiation of tendon, which paves the way for effective stepwise tendon differentiation and future tendon regeneration. Stem Cells Translational Medicine 2017;6:2009-2019. © 2017 The Authors Stem Cells Translational Medicine published by Wiley Periodicals, Inc. on behalf of AlphaMed Press.

  18. Tendon-Holding Capacities of Two Newly Designed Implants for Tendon Repair: An Experimental Study on the Flexor Digitorum Profundus Tendon of Sheep

    PubMed Central

    Ağır, İsmail; Aytekin, Mahmut Nedim; Başçı, Onur; Çaypınar, Barış; Erol, Bülent

    2014-01-01

    Background: Two main factors determine the strength of tendon repair; the tensile strength of material and the gripping capacity of a suture configuration. Different repair techniques and suture materials were developed to increase the strength of repairs but none of techniques and suture materials seem to provide enough tensile strength with safety margins for early active mobilization. In order to overcome this problem tendon suturing implants are being developed. We designed two different suturing implants. The aim of this study was to measure tendon-holding capacities of these implants biomechanically and to compare them with frequently used suture techniques Materials and Methods: In this study we used 64 sheep flexor digitorum profundus tendons. Four study groups were formed and each group had 16 tendons. We applied model 1 and model 2 implant to the first 2 groups and Bunnell and locking-loop techniques to the 3rd and 4th groups respectively by using 5 Ticron sutures. Results: In 13 tendons in group 1 and 15 tendons in group 2 and in all tendons in group 3 and 4, implants and sutures pulled out of the tendon in longitudinal axis at the point of maximum load. The mean tensile strengths were the largest in group 1 and smallest in group 3. Conclusion: In conclusion, the new stainless steel tendon suturing implants applied from outside the tendons using steel wires enable a biomechanically stronger repair with less tendon trauma when compared to previously developed tendon repair implants and the traditional suturing techniques. PMID:25067965

  19. Use of Posterior Hamstring Harvest During Anterior Cruciate Ligament Reconstruction in the Pediatric and Adolescent Population.

    PubMed

    Khanna, Krishn; Janghala, Abhinav; Pandya, Nirav K

    2018-06-01

    Posterior hamstring harvest has been described in the adult population in a limited fashion, but no study is available describing the use of posterior hamstring harvest in an active pediatric and adolescent cohort. At times, surgeons may be faced with a challenging anterior harvest due to patient anatomic characteristics, particularly the anatomic features and size of the pes tendons. Clinicians need to have multiple harvest approaches at their disposal. Complications with hamstring harvest such as premature graft transection are more problematic in this population due to higher failure rates with allograft tissue. The posterior harvest via its more proximal location may allow for easier tendon identification, visualization of the accessory attachments, and longer preserved tendon length if transection error occurs when the anterior approach is avoided based on surgical technique, patient anatomic characteristics, and surgeon and patient preference. To describe the technique of a posterior hamstring harvest in pediatric and adolescent patients and to analyze complications. Case series; Level of evidence, 4. This study was a retrospective review of a consecutive series of pediatric and adolescent patients who underwent posterior hamstring harvest. During surgery, the patient's leg was abducted and externally rotated to expose the posteromedial aspect of the knee. A 2-cm incision was made overlying the palpable medial hamstring at the popliteal crease. The posterior hamstring tendons were first harvested proximally with an open tendon stripper and distally with a closed stripper. Preoperative, intraoperative, and postoperative findings and complications were analyzed. A total of 214 patients (mean ± SD age, 15.7 ± 4.1 years; range, 8.0-19.8 years) underwent posterior harvest, with a mean ± SD follow-up of 1.83 ± 1.05 years. No complications occurred in our series related to graft harvest-no graft transections, neurovascular injuries, secondary procedures for

  20. Immediate effect of exercise on achilles tendon properties: systematic review.

    PubMed

    Obst, Steven J; Barrett, Rod S; Newsham-West, Richard

    2013-08-01

    Understanding the mechanical and morphological adaptation of the Achilles tendon (AT) in response to acute exercise could have important implications for athletic performance, injury prevention, and rehabilitation. The purpose of this study was to conduct a systematic review and critical evaluation of the literature to determine the immediate effect of a single bout of exercise on the mechanical and morphological properties of the AT in vivo. Five electronic research databases were systematically searched for intervention-based studies reporting mechanical and morphological properties of the AT after a single bout of exercise. Searches revealed 3292 possible articles; 21 met the inclusion criteria. There is evidence that maximal isometric contractions and prolonged static stretching (>5 min) of the triceps surae complex cause an immediate decrease in AT stiffness, whereas prolonged running and hopping have minimal effect. Limited but consistent evidence exists, indicating that AT hysteresis is reduced after prolonged static stretching. Consistent evidence supports a reduction in free AT diameter (anterior-posterior) after dynamic ankle exercise, and this change appears most pronounced in the healthy tendon and after eccentric exercise. The mechanical and morphological properties of the AT in vivo are affected by acute exercise in a mode- and dose-dependent manner. Transient changes in AT stiffness, hysteresis, and diameter after unaccustomed exercise modes and doses may expose the tendon to increased risk of strain injury and impact on the mechanical function of the triceps surae muscle-tendon unit.

  1. Allograft tendon reconstruction of the anterior talofibular ligament and calcaneofibular Ligament in the treatment of chronic ankle instability.

    PubMed

    Wang, Weikai; Xu, Guo Hong

    2017-04-08

    The purpose was retrospectively to investigate functional and clinical outcomes after anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL) reconstruction using a single allograft. Patients with severe chronic lateral instability of the ankle underwent surgery after conservative treatment failed. Ultrasounds of the ankle were performed, and if the AFTL and CFL were completely torn without enough soft tissue for repair, the ligaments were reconstructed using allograft tendon. Outcomes were assessed by clinical examination, stress radiography, ultrasound, the American Orthopaedic Foot and Ankle Society score (AOFAS), and Karlsson Ankle Functional score (KAFS) before surgery and at final follow-up. Nineteen patients, ten men and nine women with mean age of 27.9 years (range, 19-41 years), underwent reconstruction. Mean follow-up was 30 months (range, 24-40 months). At final follow-up, all patients had returned to activity without instability, pain, or limited range of motion. On stress radiography, mean talar tilt angle decreased from 17.32° ± 3.58° before surgery to 4.16° ± 1.12° at follow-up (p < 0.001). Mean anterior drawer test (ADT) distance decreased from 9.79 ± 1.01 mm before surgery to 3.97 ± 0.99 mm at follow-up (p < 0.05). Mean AOFAS improved from 64.00 ± 18.43 to 90.32 ± 5.17 points (p < 0.001), and mean KAFS improved from 50.84 ± 16.73 to 90.89 ± 5.08 points (p < 0.001). Ultrasound showed the reconstructed ligaments maintained good continuity and excellent tension. No case of infection and immunological rejection was reported. This novel reconstruction technique takes into account the anatomical specialty of AFTL and CFL. This case series showed increased stability of the ankle in clinical and functional outcomes. The trial registration number (TRN) and date of registration: ChiCTR-ORC-17010796 , Mar 6th 2017. Retrospectively registered.

  2. Usefulness of oblique axial scan in magnetic resonance imaging evaluation of anterior talofibular ligament in ankle sprain.

    PubMed

    Kim, Jin-su; Moon, Yong-ju; Choi, Yun Sun; Park, Young Uk; Park, Seung Min; Lee, Kyung Tai

    2012-01-01

    The purpose of the present study was to clarify the usefulness of the oblique axial scan parallel to the course of the anterior talofibular ligament in magnetic resonance imaging of the anterior talofibular ligament in patients with chronic ankle instability. We evaluated this anterior talofibular ligament view and routine axial magnetic resonance imaging planes of 115 ankles. We diagnosed the grade of the anterior talofibular ligament injury and confirmed full-length views of the anterior talofibular ligament. Associated lesions were also checked. The subjective diagnostic convenience of associated problems was determined. The full-length view of the anterior talofibular ligament was checked in 85 (73.9%) patients in the routine axial view and 112 (97.4%) patients in the anterior talofibular ligament view. The grade of injury increased in the anterior talofibular ligament view in 26 (22.6%) patients compared with the routine axial view. There were 64 associated injuries. The anterior inferior tibiofibular ligament, posterior inferior tibiofibular ligament, and posterior tibialis tendinitis were more easily diagnosed on the routine axial view than on the anterior talofibular ligament view. An additional anterior talofibular ligament view is useful in the evaluation of the anterior talofibular ligament in patients with chronic ankle instability. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Effect of posterior tibial tendon dysfunction on unipedal standing balance test.

    PubMed

    Kulig, Kornelia; Lee, Szu-Ping; Reischl, Stephen F; Noceti-DeWit, Lisa

    2015-01-01

    Foot pain and diminished functional capacity are characteristics of tibialis posterior tendon dysfunction (TPTD). This study tested the hypotheses that women with TPTD would have impaired performance of a unipedal standing balance test (USBT) and that balance performance would be related to the number of single limb heel raises (SLHR). Thirty-nine middle-aged women, 19 with early stage TPTD (stage I and II), were instructed to perform 2 tasks; a USBT and repeated SLHR. Balance success was defined as a 10-second stance. For those who were successful, center of pressure (COP) data in anterior-posterior (AP) and medial-lateral (ML) directions were recorded as a measure of postural sway. SLHR performance was divided into 3 bins (≤2; 3-9 and > 10 repetitions). The between-balance success on performing the SLHR test was analyzed using the Fisher's exact test (2 × 3). Independent t tests were used to compare between-group differences in postural sway. Relationship of postural sway to the number of heel raises was assessed using Spearman's rho. The success rate of the USBT was significantly lower in women with TPTD than the controls (47% vs 85%, P = .041). In addition, women with TPTD who completed the USBT exhibited increased AP COP displacement (14.0 ± 7.4 vs 8.4 ± 1.3 mm, P = .008), and a strong trend of increased ML COP displacement (8.3 ± 4.5 vs 6.1 ± 1.2 mm, P = .050). The success rate of USBT was correlated with the number of SLHR (P = .01). The AP and ML COP displacement were correlated with SLHR (r = -.538 and .495), respectively. Women with TPTD have difficulty in performing the USBT. Performance of the USBT and SLHR are highly correlated and predictive of each other. A unipedal balance test may be used as a proxy TPTD assessment tool to the heel raising test when pain prevents performance. Level III, case control study. © The Author(s) 2014.

  4. Tendon injuries of the hand

    PubMed Central

    Schöffl, Volker; Heid, Andreas; Küpper, Thomas

    2012-01-01

    Tendon injuries are the second most common injuries of the hand and therefore an important topic in trauma and orthopedic patients. Most injuries are open injuries to the flexor or extensor tendons, but less frequent injuries, e.g., damage to the functional system tendon sheath and pulley or dull avulsions, also need to be considered. After clinical examination, ultrasound and magnetic resonance imaging have proved to be important diagnostic tools. Tendon injuries mostly require surgical repair, dull avulsions of the distal phalanges extensor tendon can receive conservative therapy. Injuries of the flexor tendon sheath or single pulley injuries are treated conservatively and multiple pulley injuries receive surgical repair. In the postoperative course of flexor tendon injuries, the principle of early passive movement is important to trigger an “intrinsic” tendon healing to guarantee a good outcome. Many substances were evaluated to see if they improved tendon healing; however, little evidence was found. Nevertheless, hyaluronic acid may improve intrinsic tendon healing. PMID:22720265

  5. Peroneal tendon disorders

    PubMed Central

    Davda, Kinner; Malhotra, Karan; O’Donnell, Paul; Singh, Dishan; Cullen, Nicholas

    2017-01-01

    Pathological abnormality of the peroneal tendons is an under-appreciated source of lateral hindfoot pain and dysfunction that can be difficult to distinguish from lateral ankle ligament injuries. Enclosed within the lateral compartment of the leg, the peroneal tendons are the primary evertors of the foot and function as lateral ankle stabilisers. Pathology of the tendons falls into three broad categories: tendinitis and tenosynovitis, tendon subluxation and dislocation, and tendon splits and tears. These can be associated with ankle instability, hindfoot deformity and anomalous anatomy such as a low lying peroneus brevis or peroneus quartus. A thorough clinical examination should include an assessment of foot type (cavus or planovalgus), palpation of the peronei in the retromalleolar groove on resisted ankle dorsiflexion and eversion as well as testing of lateral ankle ligaments. Imaging including radiographs, ultrasound and MRI will help determine the diagnosis. Treatment recommendations for these disorders are primarily based on case series and expert opinion. The aim of this review is to summarise the current understanding of the anatomy and diagnostic evaluation of the peroneal tendons, and to present both conservative and operative management options of peroneal tendon lesions. Cite this article: EFORT Open Rev 2017;2:281-292. DOI: 10.1302/2058-5241.2.160047 PMID:28736620

  6. Peroneal tendon disorders.

    PubMed

    Davda, Kinner; Malhotra, Karan; O'Donnell, Paul; Singh, Dishan; Cullen, Nicholas

    2017-06-01

    Pathological abnormality of the peroneal tendons is an under-appreciated source of lateral hindfoot pain and dysfunction that can be difficult to distinguish from lateral ankle ligament injuries.Enclosed within the lateral compartment of the leg, the peroneal tendons are the primary evertors of the foot and function as lateral ankle stabilisers.Pathology of the tendons falls into three broad categories: tendinitis and tenosynovitis, tendon subluxation and dislocation, and tendon splits and tears. These can be associated with ankle instability, hindfoot deformity and anomalous anatomy such as a low lying peroneus brevis or peroneus quartus.A thorough clinical examination should include an assessment of foot type (cavus or planovalgus), palpation of the peronei in the retromalleolar groove on resisted ankle dorsiflexion and eversion as well as testing of lateral ankle ligaments.Imaging including radiographs, ultrasound and MRI will help determine the diagnosis. Treatment recommendations for these disorders are primarily based on case series and expert opinion.The aim of this review is to summarise the current understanding of the anatomy and diagnostic evaluation of the peroneal tendons, and to present both conservative and operative management options of peroneal tendon lesions. Cite this article: EFORT Open Rev 2017;2:281-292. DOI: 10.1302/2058-5241.2.160047.

  7. Functional tissue engineering of tendon: Establishing biological success criteria for improving tendon repair.

    PubMed

    Breidenbach, Andrew P; Gilday, Steven D; Lalley, Andrea L; Dyment, Nathaniel A; Gooch, Cynthia; Shearn, Jason T; Butler, David L

    2014-06-27

    Improving tendon repair using Functional Tissue Engineering (FTE) principles has been the focus of our laboratory over the last decade. Although our primary goals were initially focused only on mechanical outcomes, we are now carefully assessing the biological properties of our tissue-engineered tendon repairs so as to link biological influences with mechanics. However, given the complexities of tendon development and healing, it remains challenging to determine which aspects of tendon biology are the most important to focus on in the context of tissue engineering. To address this problem, we have formalized a strategy to identify, prioritize, and evaluate potential biological success criteria for tendon repair. We have defined numerous biological properties of normal tendon relative to cellular phenotype, extracellular matrix and tissue ultra-structure that we would like to reproduce in our tissue-engineered repairs and prioritized these biological criteria by examining their relative importance during both normal development and natural tendon healing. Here, we propose three specific biological criteria which we believe are essential for normal tendon function: (1) scleraxis-expressing cells; (2) well-organized and axially-aligned collagen fibrils having bimodal diameter distribution; and (3) a specialized tendon-to-bone insertion site. Moving forward, these biological success criteria will be used in conjunction with our already established mechanical success criteria to evaluate the effectiveness of our tissue-engineered tendon repairs. © 2013 Published by Elsevier Ltd.

  8. A Comparison of the Quasi-static Mechanical and Nonlinear Viscoelastic Properties of the Human Semitendinosus and Gracilis Tendons

    PubMed Central

    Abramowitch, Steven D.; Zhang, Xiaoyan; Curran, Molly; Kilger, Robert

    2010-01-01

    Background Over fifty-percent of anterior cruciate ligament reconstructions are performed using semitendinosus and gracilis tendon autografts. Despite their increased use, there remains little quantitative data on their mechanical behavior. Therefore, the objective of this study was to investigate the quasi-static mechanical and nonlinear viscoelastic properties of human semitendinosus and gracilis tendons, as well as the variation of these properties along their length. Methods Specimens were subjected to a series of uniaxial tensile tests: one-hour static stress-relaxation test, 30-cycle cyclic stress-relaxation test and load to failure test. To describe the nonlinear viscoelastic behavior, the quasi-linear viscoelastic theory was utilized to model data from the static stress relaxation experiment. Findings The constants describing the viscoelastic behavior were similar between the proximal and distal halves of the gracilis tendon. The proximal half of the semitendinosus tendon, however, had a greater viscous response than its distal half, which was also significantly higher than the proximal gracilis tendon. In terms of the quasi-static mechanical properties, the properties were similar between the proximal and distal halves of the semitendinosus tendon. However, the distal gracilis tendon showed a significantly higher tangent modulus and ultimate stress compared to its proximal half, which was also significantly higher than the distal semitendinosus tendon. Interpretation The results of this study demonstrate differences between the semitendinosus and gracilis tendons in terms of their quasi-static mechanical and nonlinear viscoelastic properties. These results are important for establishing surgical preconditioning protocols and graft selection. PMID:20092917

  9. Proteomic differences between native and tissue‐engineered tendon and ligament

    PubMed Central

    Tew, Simon R.; Peffers, Mandy; Canty‐Laird, Elizabeth G.; Comerford, Eithne

    2016-01-01

    Tendons and ligaments (T/Ls) play key roles in the musculoskeletal system, but they are susceptible to traumatic or age‐related rupture, leading to severe morbidity as well as increased susceptibility to degenerative joint diseases such as osteoarthritis. Tissue engineering represents an attractive therapeutic approach to treating T/L injury but it is hampered by our poor understanding of the defining characteristics of the two tissues. The present study aimed to determine differences in the proteomic profile between native T/Ls and tissue engineered (TE) T/L constructs. The canine long digital extensor tendon and anterior cruciate ligament were analyzed along with 3D TE fibrin‐based constructs created from their cells. Native tendon and ligament differed in their content of key structural proteins, with the ligament being more abundant in fibrocartilaginous proteins. 3D T/L TE constructs contained less extracellular matrix (ECM) proteins and had a greater proportion of cellular‐associated proteins than native tissue, corresponding to their low collagen and high DNA content. Constructs were able to recapitulate native T/L tissue characteristics particularly with regard to ECM proteins. However, 3D T/L TE constructs had similar ECM and cellular protein compositions indicating that cell source may not be an important factor for T/L tissue engineering. PMID:27080496

  10. Tendon Mineralization Is Progressive and Associated with Deterioration of Tendon Biomechanical Properties, and Requires BMP-Smad Signaling in the Mouse Achilles Tendon Injury Model

    PubMed Central

    Zhang, Kairui; Asai, Shuji; Hast, Michael W.; Liu, Min; Usami, Yu; Iwamoto, Masahiro; Soslowsky, Louis J.; Enomoto-Iwamoto, Motomi

    2016-01-01

    Ectopic tendon mineralization can develop following tendon rupture or trauma surgery. The pathogenesis of ectopic tendon mineralization and its clinical impact have not been fully elucidated yet. In this study, we utilized a mouse Achilles tendon injury model to determine whether ectopic tendon mineralization alters the biomechanical properties of the tendon and whether BMP signaling is involved in this condition. A complete transverse incision was made at the midpoint of the right Achilles tendon in 8-week-old CD1 mice and the gap was left open. Ectopic cartilaginous mass formation was found in the injured tendon by 4 weeks post-surgery and ectopic mineralization was detected at 8–10 weeks post-surgery. Ectopic mineralization grew over time and volume of the mineralized materials of 25-weeks samples was about 2.5 fold bigger than that of 10-weeks samples, indicating that injury-induced ectopic tendon mineralization is progressive. In vitro mechanical testing showed that max force, max stress and mid-substance modulus in the 25-weeks samples were significantly lower than the 10-weeks samples. We observed substantial increases in expression of bone morphogenetic protein family genes in injured tendons 1 week post-surgery. Immunohistochemical analysis showed that phosphorylation of both Smad1 and Smad3 were highly increased in injured tendons as early as 1 week post-injury and remained high in ectopic chondrogenic lesions 4 weeks post-injury. Treatment with the BMP receptor kinase inhibitor (LDN193189) significantly inhibited injury-induced tendon mineralization. These findings indicate that injury-induced ectopic tendon mineralization is progressive, involves BMP signaling and associated with deterioration of tendon biomechanical properties. PMID:26825318

  11. Multidisciplinary approach to the persistent double distal tendon of the biceps brachii.

    PubMed

    Blasi, Marc; de la Fuente, Javier; Martinoli, Carlo; Blasi, Juan; Pérez-Bellmunt, Albert; Domingo, Tomás; Miguel-Pérez, Maribel

    2014-01-01

    The aim of this study is to correlate the ultrasound (US) appearance of the persistent double or bifid distal tendon of the biceps brachii muscle with anatomical and histological data. This will provide a new model to study the pathological distal biceps brachii tendon (DBBT). The DBBT of 20 cadaveric elbows were examined with linear array broadband US transducers (frequency band 14-6 MHz) using an anterior approach. Trypan blue dye was injected underneath the paratenon under US guidance in 16 specimens. After they were dissected, five of them were processed to obtain histological slices stained with hematoxylin-eosin and antiserum to protein S100. At US, the DBBT is a tendon in which the fascicles are organized in two different hyperechoic components separated by a hyperechoic septum related to the endotenon. The endotenon is lax, flexible, and makes folding and gliding of the two portions feasible. The DBBT is surrounded by a hyperechoic paratenon adjacent to the tendon surface, which is only differentiable by US when dye is interposed between such structures. The connective septum of endotenon located between the two main components of the DBBT is responsible for the US image of two separate tendons and functionally enables it to work as two separate entities, thus allowing respective folding and gliding. The paratenon surrounding the lacertus fibrosus and the DBBT plays an important stabilization role, enabling them to change shape and arrangement during joint motion. It is also an important conduit for nerves and blood vessels.

  12. Investigating tendon mineralisation in the avian hindlimb: a model for tendon ageing, injury and disease

    PubMed Central

    Agabalyan, Natacha A; Evans, Darrell J R; Stanley, Rachael L

    2013-01-01

    Mineralisation of the tendon tissue has been described in various models of injury, ageing and disease. Often resulting in painful and debilitating conditions, the processes underlying this mechanism are poorly understood. To elucidate the progression from healthy tendon to mineralised tendon, an appropriate model is required. In this study, we describe the spontaneous and non-pathological ossification and calcification of tendons of the hindlimb of the domestic chicken (Gallus gallus domesticus). The appearance of the ossified avian tendon has been described previously, although there have been no studies investigating the developmental processes and underlying mechanisms leading to the ossified avian tendon. The tissue and cells from three tendons – the ossifying extensor and flexor digitorum longus tendons and the non-ossifying Achilles tendon – were analysed for markers of ageing and mineralisation using histology, immunohistochemistry, cytochemistry and molecular analysis. Histologically, the adult tissue showed a loss of healthy tendon crimp morphology as well as markers of calcium deposits and mineralisation. The tissue showed a lowered expression of collagens inherent to the tendon extracellular matrix and presented proteins expressed by bone. The cells from the ossified tendons showed a chondrogenic and osteogenic phenotype as well as tenogenic phenotype and expressed the same markers of ossification and calcification as the tissue. A molecular analysis of the gene expression of the cells confirmed these results. Tendon ossification within the ossified avian tendon seems to be the result of an endochondral process driven by its cells, although the roles of the different cell populations have yet to be elucidated. Understanding the role of the tenocyte within this tissue and the process behind tendon ossification may help us prevent or treat ossification that occurs in injured, ageing or diseased tendon. PMID:23826786

  13. Achilles Tendonitis

    MedlinePlus

    ... almost impossible. Achilles tendonitis is a very common running injury. But it can also affect basketball players, dancers, ... Proximal Biceps Tendonitis Safety Tips: Basketball Safety Tips: Running Repetitive Stress Injuries Sports and Exercise Safety Dealing With Sports Injuries ...

  14. The effect of seprafilm on adhesion formation and tendon healing after flexor tendon repair in chicken.

    PubMed

    Yilmaz, Erhan; Avci, Mustafa; Bulut, Mehmet; Kelestimur, Halidun; Karakurt, Lokman; Ozercan, Ibrahim

    2010-03-01

    Adhesion of the tendon, which can occur during healing of tendon repair, is negatively affected by the outcome of surgery. In this experimental study, we sought to prevent adhesion of the tendon, and determined the mechanical stiffness of repair tissue by wrapping sodium hyaluronate and carboxymethylcellulose (Seprafilm; Genzyme, Cambridge, Massachusetts) around the repaired tendon segments. The study group comprised 2 groups of 20 chickens. In group I, the right gastrocnemius tendons of the chickens were cut smoothly, and after tendon and sheath repair, the skin was sutured. In group II, the right gastrocnemius tendons of the chickens were cut, the tendons were repaired, and before skin closure, Seprafilm was wrapped around the repaired tendon segments. Plastic splints were used for holding the chickens' ankles in a neutral position, and they were allowed weight bearing for 8 weeks. In group II, anatomic space between the tendon-sheath and tendon was clear and the tendon-sheath complex was sliding easily around the repaired tendon segment, and this complex was more functional both biomechanically and histologically. Also, the Seprafilm-applied tendons (group II) were observed to be biomechanically more resistant to the tensile forces in group I. Seprafilm is an easily applied interpositional material that can be used safely to prevent adhesion during the tendon healing process. Copyright 2010, SLACK Incorporated.

  15. A Review on Biomechanics of Anterior Cruciate Ligament and Materials for Reconstruction

    PubMed Central

    Marieswaran, M.; Jain, Ishita; Garg, Bhavuk; Sharma, Vijay

    2018-01-01

    The anterior cruciate ligament is one of the six ligaments in the human knee joint that provides stability during articulations. It is relatively prone to acute and chronic injuries as compared to other ligaments. Repair and self-healing of an injured anterior cruciate ligament are time-consuming processes. For personnel resuming an active sports life, surgical repair or replacement is essential. Untreated anterior cruciate ligament tear results frequently in osteoarthritis. Therefore, understanding of the biomechanics of injury and properties of the native ligament is crucial. An abridged summary of the prominent literature with a focus on key topics on kinematics and kinetics of the knee joint and various loads acting on the anterior cruciate ligament as a function of flexion angle is presented here with an emphasis on the gaps. Briefly, we also review mechanical characterization composition and anatomy of the anterior cruciate ligament as well as graft materials used for replacement/reconstruction surgeries. The key conclusions of this review are as follows: (a) the highest shear forces on the anterior cruciate ligament occur during hyperextension/low flexion angles of the knee joint; (b) the characterization of the anterior cruciate ligament at variable strain rates is critical to model a viscoelastic behavior; however, studies on human anterior cruciate ligament on variable strain rates are yet to be reported; (c) a significant disparity on maximum stress/strain pattern of the anterior cruciate ligament was observed in the earlier works; (d) nearly all synthetic grafts have been recalled from the market; and (e) bridge-enhanced repair developed by Murray is a promising technique for anterior cruciate ligament reconstruction, currently in clinical trials. It is important to note that full extension of the knee is not feasible in the case of most animals and hence the loading pattern of human ACL is different from animal models. Many of the published reviews on

  16. Distal Biceps Tendon Rupture

    DTIC Science & Technology

    2010-06-01

    Distal Biceps Tendon Rupture Military Medicine Radiology Corner, 2006 Radiology Corner Distal Biceps Tendon Rupture Contributors: CPT Michael...treatment of a 56-year-old man with complete rupture of the distal biceps tendon . The mechanism of injury, symptoms, and findings at physical...be used in pre-operative planning. Introduction Rupture of the distal biceps tendon is a relatively uncommon injury, but delayed diagnosis may

  17. A novel remaining tendon preserving repair technique leads to improved outcomes in special rotator cuff tear patterns.

    PubMed

    Jeon, Yoon Sang; Kim, Rag Gyu; Shin, Sang-Jin

    2018-05-16

    The purpose of this study was to identify the tear pattern that could be anatomically repaired by preserving the remaining tendon on footprint and evaluate clinical outcomes of patients who underwent remaining tendon preserving cuff repair. Of 523 patients with full-thickness rotator cuff tears who underwent arthroscopic repair, 41 (7.8%) patients had repairable rotator cuff tear while preserving the remaining tendon. Among them, 31 patients were followed-up for more than 2 years, including 26 patients with posterior L-shaped tear and 5 patients with transtendinous tear patterns. Clinical outcomes were evaluated using ASES and Constant score, SANE score for patient satisfaction, and VAS for pain. MRI was taken for tendon integrity 6 months postoperatively. Of the 31 patients, 11 (35.5%) had previous injury history before rotator cuff tear, including 7 (26.9%) of the 26 patients with posterior L-shaped tear and 4 (80%) of the 5 patients with transtendinous tear. The average size of preoperative cuff tear was 17.8 ± 6.8 mm in anterior-to-posterior direction and 15.2 ± 5.1 mm in medial-to-lateral direction. ASES and Constant score, SANE score, and VAS for pain were significantly (p < 0.001) improved after remaining tendon preserving rotator cuff repair. Rotator cuff tendons of 22(84.6%) patients with posterior L-shaped tear and 4(80%) patients with transtendinous tear patterns were healed. Patients who underwent rotator cuff repair with preservation of the remaining tendon on the footprint obtained satisfactory functional outcomes. Rotator cuff tears in patients who had posterior L-shaped tear extending between supraspinatus and infraspinatus tendons or transtendinous tear pattern with substantial remaining tendon could be repaired using remaining tendon preserving repair technique. Anatomic reduction of torn cuff tendon without undue tension could be achieved using the remaining tendon preserving repair technique.

  18. Tendon Functional Extracellular Matrix

    PubMed Central

    Screen, H.R.C.; Birk, D.E.; Kadler, K.E.; Ramirez, F; Young, M.F.

    2015-01-01

    This article is one of a series, summarising views expressed at the Orthopaedic Research Society New Frontiers in Tendon Research Conference. This particular article reviews the three workshops held under the “Functional Extracellular Matrix” stream. The workshops focused on the roles of the tendon extracellular matrix, such as performing the mechanical functions of tendon, creating the local cell environment and providing cellular cues. Tendon is a complex network of matrix and cells, and its biological functions are influenced by widely-varying extrinsic and intrinsic factors such as age, nutrition, exercise levels and biomechanics. Consequently, tendon adapts dynamically during development, ageing and injury. The workshop discussions identified research directions associated with understanding cell-matrix interactions to be of prime importance for developing novel strategies to target tendon healing or repair. PMID:25640030

  19. Therapeutics for tendon regeneration: a multidisciplinary review of tendon research for improved healing.

    PubMed

    Paredes, J J; Andarawis-Puri, Nelly

    2016-11-01

    Tendon injuries, known as tendinopathies, are common musculoskeletal injuries that affect a wide range of the population. Canonical tendon healing is characterized by fibrosis, scar formation, and the loss of tissue mechanical and structural properties. Understanding the regenerative tendon environment is an area of increasing interest in the field of musculoskeletal research. Previous studies have focused on utilizing individual elements from the fields of biomechanics, developmental biology, cell and growth factor therapy, and tissue engineering in an attempt to develop regenerative tendon therapeutics. Still, the specific mechanism for regenerative healing remains unknown. In this review, we highlight some of the current approaches of tendon therapeutics and elucidate the differences along the tendon midsubstance and enthesis, exhibiting the necessity of location-specific tendon therapeutics. Furthermore, we emphasize the necessity of further interdisciplinary research in order to reach the desired goal of fully understanding the mechanisms underlying regenerative healing. © 2016 New York Academy of Sciences.

  20. Neuronal regulation of tendon homoeostasis

    PubMed Central

    Ackermann, Paul W

    2013-01-01

    The regulation of tendon homoeostasis, including adaptation to loading, is still not fully understood. Accumulating data, however, demonstrates that in addition to afferent (sensory) functions, the nervous system, via efferent pathways which are associated with through specific neuronal mediators plays an active role in regulating pain, inflammation and tendon homeostasis. This neuronal regulation of intact-, healing- and tendinopathic tendons has been shown to be mediated by three major groups of molecules including opioid, autonomic and excitatory glutamatergic neuroregulators. In intact healthy tendons the neuromediators are found in the surrounding structures: paratenon, endotenon and epitenon, whereas the proper tendon itself is practically devoid of neurovascular supply. This neuroanatomy reflects that normal tendon homoeostasis is regulated from the tendon surroundings. After injury and during tendon repair, however, there is extensive nerve ingrowth into the tendon proper, followed by a time-dependent emergence of sensory, autonomic and glutamatergic mediators, which amplify and fine-tune inflammation and regulate tendon regeneration. In tendinopathic condition, excessive and protracted presence of sensory and glutamatergic neuromediators has been identified, suggesting involvement in inflammatory, nociceptive and hypertrophic (degenerative) tissue responses. Under experimental and clinical conditions of impaired (e.g. diabetes) as well as excessive (e.g. tendinopathy) neuromediator release, dysfunctional tendon homoeostasis develops resulting in chronic pain and gradual degeneration. Thus there is a prospect that in the future pharmacotherapy and tissue engineering approaches targeting neuronal mediators and their receptors may prove to be effective therapies for painful, degenerative and traumatic tendon disorders. PMID:23718724

  1. Kartogenin with PRP promotes the formation of fibrocartilage zone in the tendon-bone interface.

    PubMed

    Zhou, Yiqin; Zhang, Jianying; Yang, Jinsong; Narava, Manoj; Zhao, Guangyi; Yuan, Ting; Wu, Haishan; Zheng, Nigel; Hogan, MaCalus V; Wang, James H-C

    2017-12-01

    Treatment of tendon-bone junction injuries is a challenge because tendon-bone interface often heals poorly and the fibrocartilage zone, which reduces stress concentration, at the interface is not formed. In this study, we used a compound called kartogenin (KGN) with platelet-rich plasma (PRP) to induce the formation of fibrocartilage zone in a rat tendon graft-bone tunnel model. The experimental rats received KGN-PRP or PRP injections in the tendon graft-bone tunnel interface. The control group received saline. After 4, 8 and 12 weeks, Safranin O staining of the tendon graft-bone tunnels revealed abundant proteoglycans in the KGN-PRP group indicating the formation of cartilage-like transition zone. Immunohistochemical and immuno-fluorescence staining revealed collagen types I (Col-I) and II (Col-II) in the newly formed fibrocartilage zone. Both fibrocartilage zone formation and maturation were healing time dependent. In contrast, the PRP and saline control groups had no cartilage-like tissues and minimal Col-I and Col-II staining. Some gaps were also present in the saline control group. Finally, pull-out strength in the KGN-PRP-treated group at 8 weeks was 1.4-fold higher than the PRP-treated group and 1.6-fold higher than the saline control group. These findings indicate that KGN, with PRP as a carrier, promotes the formation of fibrocartilage zone between the tendon graft and bone interface. Thus, KGN-PRP may be used as a convenient cell-free therapy in clinics to promote fibrocartilage zone formation in rotator calf repair and anterior cruciate ligament reconstruction, thereby enhancing the mechanical strength of the tendon-bone interface and hence the clinical outcome of these procedures. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  2. Angiopoietin‐like 4 promotes angiogenesis in the tendon and is increased in cyclically loaded tendon fibroblasts

    PubMed Central

    Mousavizadeh, Rouhollah; Scott, Alex; Lu, Alex; Ardekani, Gholamreza S; Behzad, Hayedeh; Lundgreen, Kirsten; Ghaffari, Mazyar; McCormack, Robert G

    2016-01-01

    Key points Angiopoietin‐like 4 (ANGPTL4) modulates tendon neovascularization.Cyclic loading stimulates the activity of transforming growth factor‐β and hypoxia‐inducible factor 1α and thereby increases the expression and release of ANGPTL4 from human tendon cells.Targeting ANGPTL4 and its regulatory pathways is a potential avenue for regulating tendon vascularization to improve tendon healing or adaptation. Abstract The mechanisms that regulate angiogenic activity in injured or mechanically loaded tendons are poorly understood. The present study examined the potential role of angiopoietin‐like 4 (ANGPTL4) in the angiogenic response of tendons subjected to repetitive mechanical loading or injury. Cyclic stretching of human tendon fibroblasts stimulated the expression and release of ANGPTL4 protein via transforming growth factor‐β (TGF‐β) and hypoxia‐inducible factor 1α (HIF‐1α) signalling, and the released ANGPTL4 was pro‐angiogenic. Angiogenic activity was increased following ANGPTL4 injection into mouse patellar tendons, whereas the patellar tendons of ANGPTL4 knockout mice displayed reduced angiogenesis following injury. In human rotator cuff tendons, the expression of ANGPTL4 was correlated with the density of tendon endothelial cells. To our knowledge, this is the first study characterizing a role of ANGPTL4 in the tendon. ANGPTL4 may assist in the regulation of vascularity in the injured or mechanically loaded tendon. TGF‐β and HIF‐1α comprise two signalling pathways that modulate the expression of ANGPTL4 by mechanically stimulated tendon fibroblasts and, in the future, these could be manipulated to influence tendon healing or adaptation. PMID:26670924

  3. How Obesity Affects Tendons?

    PubMed

    Abate, Michele; Salini, Vincenzo; Andia, Isabel

    Several epidemiological and clinical observations have definitely demonstrated that obesity has harmful effects on tendons. The pathogenesis of tendon damage is multi-factorial. In addition to overload, attributable to the increased body weight, which significantly affects load-bearing tendons, systemic factors play a relevant role. Several bioactive peptides (chemerin, leptin, adiponectin and others) are released by adipocytes, and influence tendon structure by means of negative activities on mesenchymal cells. The ensuing systemic state of chronic, sub-clinic, low-grade inflammation can damage tendon structure. Metabolic disorders (diabetes, impaired glucose tolerance, and dislipidemia), frequently associated with visceral adiposity, are concurrent pathogenetic factors. Indeed, high glucose levels increase the formation of Advanced Glycation End-products, which in turn form stable covalent cross-links within collagen fibers, modifying their structure and functionality.Sport activities, so useful for preventing important cardiovascular complications, may be detrimental for tendons if they are submitted to intense acute or chronic overload. Therefore, two caution rules are mandatory: first, to engage in personalized soft training program, and secondly to follow regular check-up for tendon pathology.

  4. Editorial Commentary: All-Inside Anterior Cruciate Ligament Reconstruction Can Afford Satisfactory Clinical Outcome and Functional Stability.

    PubMed

    Yoshiya, Shinichi

    2016-02-01

    Anatomic all-inside anterior cruciate ligament reconstruction using the autogenous semitendinosus tendon graft can afford satisfactory outcomes, achieving significant postoperative improvement in all clinical parameters. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  5. Lubricin Surface Modification Improves Tendon Gliding After Tendon Repair in a Canine Model in Vitro

    PubMed Central

    Taguchi, Manabu; Sun, Yu-Long; Zhao, Chunfeng; Zobitz, Mark E.; Cha, Chung-Ja; Jay, Gregory D.; An, Kai-Nan; Amadio, Peter C.

    2011-01-01

    This study investigated the effects of lubricin on the gliding of repaired flexor digitorum profundus (FDP) tendons in vitro. Canine FDP tendons were completely lacerated, repaired with a modified Pennington technique, and treated with one of the following solutions: saline, carbodiimide derivatized gelatin/hyaluronic acid (cd-HA-gelatin), carbodiimide derivatized gelatin to which lubricin was added in a second step (cd-gelatin + lubricin), or carbodiimide derivatized gelatin/HA + lubricin (cd-HA-gelatin + lubricin). After treatment, gliding resistance was measured up to 1,000 cycles of simulated flexion/extension motion. The increase in average and peak gliding resistance in cd-HA-gelatin, cd-gelatin + lubricin, and cd-HA-gelatin + lubricin tendons was less than the control tendons after 1,000 cycles (p < 0.05). The increase in average gliding resistance of cd-HA-gelatin + lubricin treated tendons was also less than that of the cd-HA-gelatin treated tendons (p < 0.05). The surfaces of the repaired tendons and associated pulleys were assessed qualitatively with scanning electron microscopy and appeared smooth after 1,000 cycles of tendon motion for the cd-HA-gelatin, cd-gelatin + lubricin, and cd-HA-gelatin + lubricin treated tendons, while that of the saline control appeared roughened. These results suggest that tendon surface modification can improve tendon gliding ability, with a trend suggesting that lubricin fixed on the repaired tendon may provide additional improvement over that provided by HA and gelatin alone. PMID:18683890

  6. Angiopoietin-like 4 promotes angiogenesis in the tendon and is increased in cyclically loaded tendon fibroblasts.

    PubMed

    Mousavizadeh, Rouhollah; Scott, Alex; Lu, Alex; Ardekani, Gholamreza S; Behzad, Hayedeh; Lundgreen, Kirsten; Ghaffari, Mazyar; McCormack, Robert G; Duronio, Vincent

    2016-06-01

    Angiopoietin-like 4 (ANGPTL4) modulates tendon neovascularization. Cyclic loading stimulates the activity of transforming growth factor-β and hypoxia-inducible factor 1α and thereby increases the expression and release of ANGPTL4 from human tendon cells. Targeting ANGPTL4 and its regulatory pathways is a potential avenue for regulating tendon vascularization to improve tendon healing or adaptation. The mechanisms that regulate angiogenic activity in injured or mechanically loaded tendons are poorly understood. The present study examined the potential role of angiopoietin-like 4 (ANGPTL4) in the angiogenic response of tendons subjected to repetitive mechanical loading or injury. Cyclic stretching of human tendon fibroblasts stimulated the expression and release of ANGPTL4 protein via transforming growth factor-β (TGF-β) and hypoxia-inducible factor 1α (HIF-1α) signalling, and the released ANGPTL4 was pro-angiogenic. Angiogenic activity was increased following ANGPTL4 injection into mouse patellar tendons, whereas the patellar tendons of ANGPTL4 knockout mice displayed reduced angiogenesis following injury. In human rotator cuff tendons, the expression of ANGPTL4 was correlated with the density of tendon endothelial cells. To our knowledge, this is the first study characterizing a role of ANGPTL4 in the tendon. ANGPTL4 may assist in the regulation of vascularity in the injured or mechanically loaded tendon. TGF-β and HIF-1α comprise two signalling pathways that modulate the expression of ANGPTL4 by mechanically stimulated tendon fibroblasts and, in the future, these could be manipulated to influence tendon healing or adaptation. © 2015 The Authors. The Journal of Physiology © 2015 The Physiological Society.

  7. The Influence of a Cognitive Task on the Postural Phase of Gait Initiation in Parkinson's Disease: An Electromyographic-Based Analysis.

    PubMed

    Fernandes, Ângela; Sousa, Andreia S P; Rocha, Nuno; Tavares, João Manuel R S

    2017-07-01

    The aim of this study was to compare postural control strategies during gait initiation in single- and dual-task conditions in individuals in early stages of Parkinson's Disease (PD). The activation timing of tibialis anterior occurred significantly later in the individuals with PD than in the controls (p = .05), and a significant interaction between the groups, conditions and limbs was found (p = .027). Differences between the single- and dual-task conditions were observed for the activation timing of the tibialis anterior (p = .042) and for the magnitude of soleus (p = .007), with lower values for the dual-task condition. Furthermore, not all the individuals followed the previously reported pattern of soleus inhibition followed by tibialis anterior activation. The duration of the mediolateral displacement of the center of pressure was longer in the individuals with PD than in the controls (p = .019). The anticipatory postural adjustments during gait initiation are impaired in PD and are expressed by an activation failure of tibialis anterior in both single- and dual-task conditions. Hence, it is important that during rehabilitation, intervention should concentrate on the tibialis anterior TA.

  8. Radioprotection provides functional mechanics but delays healing of irradiated tendon allografts after ACL reconstruction in sheep.

    PubMed

    Seto, Aaron U; Culp, Brian M; Gatt, Charles J; Dunn, Michael

    2013-12-01

    Successful protection of tissue properties against ionizing radiation effects could allow its use for terminal sterilization of musculoskeletal allografts. In this study we functionally evaluate Achilles tendon allografts processed with a previously developed radioprotective treatment based on (1-ethyl-3-(3-dimethylaminopropyl)carbodiimide) crosslinking and free radical scavenging using ascorbate and riboflavin, for ovine anterior cruciate ligament reconstruction. Arthroscopic anterior cruciate ligament (ACL) reconstruction was performed using double looped allografts, while comparing radioprotected irradiated and fresh frozen allografts after 12 and 24 weeks post-implantation, and to control irradiated grafts after 12 weeks. Radioprotection was successful at preserving early subfailure mechanical properties comparable to fresh frozen allografts. Twelve week graft stiffness and anterior-tibial (A-T) translation for radioprotected and fresh frozen allografts were comparable at 30 % of native stiffness, and 4.6 and 5 times native A-T translation, respectively. Fresh frozen allograft possessed the greatest 24 week peak load at 840 N and stiffness at 177 N/mm. Histological evidence suggested a delay in tendon to bone healing for radioprotected allografts, which was reflected in mechanical properties. There was no evidence that radioprotective treatment inhibited intra-articular graft healing. This specific radioprotective method cannot be recommended for ACL reconstruction allografts, and data suggest that future efforts to improve allograft sterilization procedures should focus on modifying or eliminating the pre-crosslinking procedure.

  9. Synovial Mesenchymal Stem Cells Promote Meniscus Regeneration Augmented by an Autologous Achilles Tendon Graft in a Rat Partial Meniscus Defect Model

    PubMed Central

    Ozeki, Nobutake; Muneta, Takeshi; Matsuta, Seiya; Koga, Hideyuki; Nakagawa, Yusuke; Mizuno, Mitsuru; Tsuji, Kunikazu; Mabuchi, Yo; Akazawa, Chihiro; Kobayashi, Eiji; Saito, Tomoyuki; Sekiya, Ichiro

    2015-01-01

    Although meniscus defects and degeneration are strongly correlated with the later development of osteoarthritis, the promise of regenerative medicine strategies is to prevent and/or delay the disease's progression. Meniscal reconstruction has been shown in animal models with tendon grafting and transplantation of mesenchymal stem cells (MSCs); however, these procedures have not shown the same efficacy in clinical studies. Here, our aim was to investigate the ability of tendon grafts pretreated with exogenous synovial-derived MSCs to prevent cartilage degeneration in a rat partial meniscus defect model. We removed the anterior half of the medial meniscus and grafted autologous Achilles tendons with or without a 10-minute pretreatment of the tendon with synovial MSCs. The meniscus and surrounding cartilage were evaluated at 2, 4, and 8 weeks (n = 5). Tendon grafts increased meniscus size irrespective of synovial MSCs. Histological scores for regenerated menisci were better in the tendon + MSC group than in the other two groups at 4 and 8 weeks. Both macroscopic and histological scores for articular cartilage were significantly better in the tendon + MSC group at 8 weeks. Implanted synovial MSCs survived around the grafted tendon and native meniscus integration site by cell tracking assays with luciferase+, LacZ+, DiI+, and/or GFP+ synovial MSCs and/or GFP+ tendons. Flow cytometric analysis showed that transplanted synovial MSCs retained their MSC properties at 7 days and host synovial tissue also contained cells with MSC characteristics. Synovial MSCs promoted meniscus regeneration augmented by autologous Achilles tendon grafts and prevented cartilage degeneration in rats. Stem Cells 2015;33:1927–1938 PMID:25993981

  10. [Achilles tendon rupture].

    PubMed

    Thermann, H; Hüfner, T; Tscherne, H

    2000-03-01

    The treatment of acute of Achilles tendon rupture experienced a dynamic development in the last ten years. Decisive for this development was the application of MRI and above all the ultrasonography in the diagnostics of the pathological changes and injuries of tendons. The question of rupture morphology as well as different courses of healing could be now evaluated objectively. These advances led consequently to new modalities in treatment concepts and rehabilitation protocols. The decisive input for improvements of the outcome results and particularly the shortening of the rehabilitation period came with introduction of the early functional treatment in contrast to immobilizing plaster treatment. In a prospective randomized study (1987-1989) at the Trauma Dept. of the Hannover Medical School could show no statistical differences comparing functional non-operative with functional operative therapy with a special therapy boot (Variostabil/Adidas). The crucial criteria for therapy selection results from the sonographically measured position of the tendon stumps in plantar flexion (20 degrees). With complete adaptation of the tendons' ends surgical treatment does not achieve better results than non-operative functional treatment in term of tendon healing and functional outcome. Regarding the current therapeutic standards each method has is advantages and disadvantages. Both, the operative and non-operative functional treatment enable a stable tendon healing with a low risk of re-rupture (1-2%). Meanwhile there is consensus for early functional after-treatment of the operated Achilles' tendons. There seems to be a trend towards non-operative functional treatment in cases of adequate sonographical findings, or to minimal invasive surgical techniques.

  11. Modified Kidner procedure utilizing a Mitek bone anchor.

    PubMed

    Dawson, D M; Julsrud, M E; Erdmann, B B; Jacobs, P M; Ringstrom, J B

    1998-01-01

    The recent development of small bone suture anchors has created several potential applications in reconstructive surgery of the foot. Mitek bone anchors are simple to insert, require less aggressive dissection and surgical time than reefing of the redundant posterior tibial tendon, and are a reliable method of tendon-to-bone fixation. Mitek bone anchors are an excellent technique for the treatment of redundant tibialis posterior tendon following a modified Kidner procedure. In modified Kidner procedures involving an excessively large os tibiale externum, Mitek anchoring of the redundant tibialis posterior tendon to the navicular bone is an excellent means for secure plication of the posterior tibial tendon in cases involving intraoperative tendon laxity. A description of the Mitek Anchor System and technique of application in a modified Kinder procedure is presented. The purpose of this study was to describe patient satisfaction and long-term clinical outcomes of the modified Kinder procedure with and without the Mitek bone anchoring system. A retrospective study of the modified Kinder procedure was performed with 13 patients being evaluated, seven with Mitek anchoring and six without. The University of Maryland 100-point Painful Foot Center Scoring System was modified to be more specific to the modified Kinder procedure for assessment of subjective long-term results. Patient overall satisfaction was rated good to excellent by 85.6% of patients in the Mitek group and by 100% of patients in the non-Mitek group. Use of the Mitek anchor allowed for quicker postoperative recovery to resumption of ambulation without assistive devices (average of 3 weeks vs. 4.42 weeks) and a quicker return to pain-free ambulation in normal shoegear (average of 4 weeks vs. 6 weeks). Mitek anchoring of the tibialis posterior tendon, theoretically, increases medial arch support as evidenced by 14% of the Mitek group and 67% of the non-Mitek group requiring postoperative orthotics.

  12. Assessment of Postoperative Tendon Quality in Patients With Achilles Tendon Rupture Using Diffusion Tensor Imaging and Tendon Fiber Tracking.

    PubMed

    Sarman, Hakan; Atmaca, Halil; Cakir, Ozgur; Muezzinoglu, Umit Sefa; Anik, Yonca; Memisoglu, Kaya; Baran, Tuncay; Isik, Cengiz

    2015-01-01

    Although pre- and postoperative imaging of Achilles tendon rupture (ATR) has been well documented, radiographic evaluations of postoperative intratendinous healing and microstructure are still lacking. Diffusion tensor imaging (DTI) is an innovative technique that offers a noninvasive method for describing the microstructure characteristics and organization of tissues. DTI was used in the present study for quantitative assessment of fiber continuity postoperatively in patients with acute ATR. The data from 16 patients with ATR from 2005 to 2012 were retrospectively analyzed. The microstructure of ART was evaluated using tendon fiber tracking, tendon continuity, fractional anisotropy, and apparent diffusion coefficient values by way of DTI. The distal and proximal portions were measured separately in both the ruptured and the healthy extremities of each patient. The mean patient age was 41.56 ± 8.49 (range 26 to 56) years. The median duration of follow-up was 21 (range 6 to 80) months. The tendon fractional anisotropy values of the ruptured Achilles tendon were significantly lower statistically than those of the normal side (p = .001). However, none of the differences between the 2 groups with respect to the distal and proximal apparent diffusion coefficient were statistically significant (p = .358 and p = .899, respectively). In addition, the fractional anisotropy and apparent diffusion coefficient measurements were not significantly different in the proximal and distal regions of the ruptured tendons compared with the healthy tendons. The present study used DTI and fiber tracking to demonstrate the radiologic properties of postoperative Achilles tendons with respect to trajectory and tendinous fiber continuity. Quantifying DTI and fiber tractography offers an innovative and effective tool that might be able to detect microstructural abnormalities not appreciable using conventional radiologic techniques. Copyright © 2015 American College of Foot and Ankle

  13. Motor unit number estimates and neuromuscular transmission in the tibialis anterior of master athletes: evidence that athletic older people are not spared from age-related motor unit remodeling.

    PubMed

    Piasecki, Mathew; Ireland, Alex; Coulson, Jessica; Stashuk, Dan W; Hamilton-Wright, Andrew; Swiecicka, Agnieszka; Rutter, Martin K; McPhee, Jamie S; Jones, David A

    2016-10-01

    Muscle motor unit numbers decrease markedly in old age, while remaining motor units are enlarged and can have reduced neuromuscular junction transmission stability. However, it is possible that regular intense physical activity throughout life can attenuate this remodeling. The aim of this study was to compare the number, size, and neuromuscular junction transmission stability of tibialis anterior (TA) motor units in healthy young and older men with those of exceptionally active master runners. The distribution of motor unit potential (MUP) size was determined from intramuscular electromyographic signals recorded in healthy male Young (mean ± SD, 26 ± 5 years), Old (71 ± 4 years) and Master Athletes (69 ± 3 years). Relative differences between groups in numbers of motor units was assessed using two methods, one comparing MUP size and muscle cross-sectional area (CSA) determined with MRI, the other comparing surface recorded MUPs with maximal compound muscle action potentials and commonly known as a "motor unit number estimate (MUNE)". Near fiber (NF) jiggle was measured to assess neuromuscular junction transmission stability. TA CSA did not differ between groups. MUNE values for the Old and Master Athletes were 45% and 40%, respectively, of the Young. Intramuscular MUPs of Old and Master Athletes were 43% and 56% larger than Young. NF jiggle was slightly higher in the Master Athletes, with no difference between Young and Old. These results show substantial and similar motor unit loss and remodeling in Master Athletes and Old individuals compared with Young, which suggests that lifelong training does not attenuate the age-related loss of motor units. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  14. Proteomic differences between native and tissue-engineered tendon and ligament.

    PubMed

    Kharaz, Yalda A; Tew, Simon R; Peffers, Mandy; Canty-Laird, Elizabeth G; Comerford, Eithne

    2016-05-01

    Tendons and ligaments (T/Ls) play key roles in the musculoskeletal system, but they are susceptible to traumatic or age-related rupture, leading to severe morbidity as well as increased susceptibility to degenerative joint diseases such as osteoarthritis. Tissue engineering represents an attractive therapeutic approach to treating T/L injury but it is hampered by our poor understanding of the defining characteristics of the two tissues. The present study aimed to determine differences in the proteomic profile between native T/Ls and tissue engineered (TE) T/L constructs. The canine long digital extensor tendon and anterior cruciate ligament were analyzed along with 3D TE fibrin-based constructs created from their cells. Native tendon and ligament differed in their content of key structural proteins, with the ligament being more abundant in fibrocartilaginous proteins. 3D T/L TE constructs contained less extracellular matrix (ECM) proteins and had a greater proportion of cellular-associated proteins than native tissue, corresponding to their low collagen and high DNA content. Constructs were able to recapitulate native T/L tissue characteristics particularly with regard to ECM proteins. However, 3D T/L TE constructs had similar ECM and cellular protein compositions indicating that cell source may not be an important factor for T/L tissue engineering. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Tension degradation of anterior cruciate ligament grafts with dynamic flexion-extension loading: a biomechanical model in porcine knees.

    PubMed

    Dargel, Jens; Koebke, Jürgen; Brüggemann, Gert-Peter; Pennig, Dietmar; Schmidt-Wiethoff, Rüdiger

    2009-10-01

    This study investigates the influence of various femoral anterior cruciate ligament graft fixation methods on the amount of tension degradation and the initial fixation strength after cyclic flexion-extension loading in a porcine knee model. One hundred twenty porcine digital extensor tendons, used as 4-stranded free tendon grafts, were fixated within porcine femoral bone tunnels by use of extracortical button, cross-pin, or interference screw fixation. One hundred twenty porcine patellar tendon-bone grafts were fixated by use of cross-pin, interference screw, or press-fit fixation. Each femur-graft complex was submitted to cyclic flexion-extension loading for 1,000 cycles throughout different loading ranges, and the total loss of tension was determined. After cyclic testing, the grafts were loaded to failure, and the data were compared with a pullout series without cyclic loading. Tension degradation after 1,000 cycles of flexion-extension loading averaged 62.6% +/- 10.0% in free tendon grafts and 48.9% +/- 13.35% in patellar tendon-bone grafts. There was no influence of the loading range on the total amount of tension degradation. The total amount of tension degradation was the highest with interference screw fixation of free tendon and patellar tendon-bone grafts. Despite excessive loss of tension, the initial fixation strength of the femur-graft complex was not reduced. The method of femoral graft fixation significantly influenced tension degradation during dynamic flexion-extension loading. Femoral graft fixation methods that secure the graft close to the tunnel entrance and that displace the graft substance from the center of the bone tunnel show the largest amount of tension degradation during cyclic flexion-extension loading. The graft substance, not the fixation site, was the weakest link of the graft complex within this investigation. We believe that the graft fixation method should be considered when aiming to improve the precision of femoral graft

  16. ANATOMICAL RECONSTRUCTION OF ANTERIOR CRUCIATE LIGAMENT OF THE KNEE: DOUBLE BAND OR SINGLE BAND?

    PubMed

    Zanella, Luiz Antonio Zanotelli; Junior, Adair Bervig; Badotti, Augusto Alves; Michelin, Alexandre Froes; Algarve, Rodrigo Ilha; de Quadros Martins, Cesar Antonio

    2012-01-01

    To evaluate the double-band and single-band techniques for anatomical reconstruction of the anterior cruciate ligament of the knee and demonstrate that the double-band technique not only provides greater anterior stability but also causes less pain and a better subjective patient response. We selected 42 patients who underwent anterior cruciate ligament reconstruction, by means of either the single-band anatomical reconstruction technique, using flexor tendon grafts with two tunnels, or the double-band anatomical reconstruction technique, using four tunnels and grafts from the semitendinosus and gracilis tendons. All fixations were performed using interference screws. There was no variation in the sample. Before the operation, the objective and subjective IKDC scores, Lysholm score and length of time with the injury were evaluated. All these variables were reassessed six months later, and the KT-1000 correlation with the contralateral knee was also evaluated. There was no significant difference between the two groups in subjective evaluations, but the single-band group showed better results in relation to range of motion and objective evaluations including KT-1000 (with statistical significance). Our study demonstrated that there was no difference between the two groups in subjective evaluations, but better results were found using the single-band anatomical technique, in relation to objective evaluations.

  17. ANATOMICAL RECONSTRUCTION OF ANTERIOR CRUCIATE LIGAMENT OF THE KNEE: DOUBLE BAND OR SINGLE BAND?

    PubMed Central

    Zanella, Luiz Antonio Zanotelli; Junior, Adair Bervig; Badotti, Augusto Alves; Michelin, Alexandre Froes; Algarve, Rodrigo Ilha; de Quadros Martins, Cesar Antonio

    2015-01-01

    Objective: To evaluate the double-band and single-band techniques for anatomical reconstruction of the anterior cruciate ligament of the knee and demonstrate that the double-band technique not only provides greater anterior stability but also causes less pain and a better subjective patient response. Methods: We selected 42 patients who underwent anterior cruciate ligament reconstruction, by means of either the single-band anatomical reconstruction technique, using flexor tendon grafts with two tunnels, or the double-band anatomical reconstruction technique, using four tunnels and grafts from the semitendinosus and gracilis tendons. All fixations were performed using interference screws. There was no variation in the sample. Before the operation, the objective and subjective IKDC scores, Lysholm score and length of time with the injury were evaluated. All these variables were reassessed six months later, and the KT-1000 correlation with the contralateral knee was also evaluated. Results: There was no significant difference between the two groups in subjective evaluations, but the single-band group showed better results in relation to range of motion and objective evaluations including KT-1000 (with statistical significance). Conclusion: Our study demonstrated that there was no difference between the two groups in subjective evaluations, but better results were found using the single-band anatomical technique, in relation to objective evaluations. PMID:27042621

  18. [Rupture of the Achilles tendon].

    PubMed

    Ulmar, B; Simon, S; Eschler, A; Mittlmeier, T

    2014-10-01

    The rupture of the Achilles tendon is the most frequent tendon rupture in humans and it is associated with increasing incidence. The main risk factor is intrinsic degeneration of the tendon. During the rupture the person feels a whiplash or dagger thrust-like pain, followed by restricted walking ability and decreased plantar flexion of the ankle. The positive Simmond/Thompson test and a palpable dent above the tendon rupture are pathognomical. Diagnostically, ultrasound of the tendon and lateral x-ray of the calcaneus (bony pull-out of the tendon insertion) are necessary. Regarding correct indication and treatment modalities, most established conservative and surgical therapies realize optimal functional results. Surgical treatment promises better primary stability and slightly earlier better functional results, but there is the potential for surgical complications. Conservative therapy is associated with higher rates of re-rupture and healing of the tendon under elongation. Therefore, therapy planning in Achilles tendon rupture should be determined based on each patient. We recommend surgical treatment in patients with higher sporting demands and in younger patients (< 50 years).

  19. Tendon elasticity and muscle function.

    PubMed

    Alexander, R McNeill

    2002-12-01

    Vertebrate animals exploit the elastic properties of their tendons in several different ways. Firstly, metabolic energy can be saved in locomotion if tendons stretch and then recoil, storing and returning elastic strain energy, as the animal loses and regains kinetic energy. Leg tendons save energy in this way when birds and mammals run, and an aponeurosis in the back is also important in galloping mammals. Tendons may have similar energy-saving roles in other modes of locomotion, for example in cetacean swimming. Secondly, tendons can recoil elastically much faster than muscles can shorten, enabling animals to jump further than they otherwise could. Thirdly, tendon elasticity affects the control of muscles, enhancing force control at the expense of position control.

  20. Fatigue loading of tendon

    PubMed Central

    Shepherd, Jennifer H; Screen, Hazel R C

    2013-01-01

    Tendon injuries, often called tendinopathies, are debilitating and painful conditions, generally considered to develop as a result of tendon overuse. The aetiology of tendinopathy remains poorly understood, and whilst tendon biopsies have provided some information concerning tendon appearance in late-stage disease, there is still little information concerning the mechanical and cellular events associated with disease initiation and progression. Investigating this in situ is challenging, and numerous models have been developed to investigate how overuse may generate tendon fatigue damage and how this may relate to tendinopathy conditions. This article aims to review these models and our current understanding of tendon fatigue damage. We review the strengths and limitations of different methodologies for characterizing tendon fatigue, considering in vitro methods that adopt both viable and non-viable samples, as well as the range of different in vivo approaches. By comparing data across model systems, we review the current understanding of fatigue damage development. Additionally, we compare these findings with data from tendinopathic tissue biopsies to provide some insights into how these models may relate to the aetiology of tendinopathy. Fatigue-induced damage consistently highlights the same microstructural, biological and mechanical changes to the tendon across all model systems and also correlates well with the findings from tendinopathic biopsy tissue. The multiple testing routes support matrix damage as an important contributor to tendinopathic conditions, but cellular responses to fatigue appear complex and often contradictory. PMID:23837793

  1. Endoscopic treatment of snapping hips, iliotibial band, and iliopsoas tendon.

    PubMed

    Ilizaliturri, Victor M; Camacho-Galindo, Javier

    2010-06-01

    Indications for endoscopic surgery of the hip have expanded recently. The technique has found a clear indication in the management of snapping hip syndromes, both external snapping hip and internal snapping hip. Even though the snapping hips (external and internal) share a common name, they are very different in origin. The external snapping hip is produced by the iliotibial band snapping over the prominence of the greater trochanter during flexion and extension. Indication for surgical treatment is painful snapping with failure of conservative treatment. The endoscopic technique is designed to release the iliotibial band producing a diamond shape defect on the iliotibial band lateral to the greater trochanter. The defect allows the greater trochanter to move freely without snapping. The greater trochanteric bursa is resected through the defect and the abductor tendons inspected. This procedure is performed without traction and usually only the peritrochanteric space is accessed. If necessary, hip arthroscopy can also be performed. There is limited literature regarding the results of endoscopic treatment for the external snapping hip syndrome, but early reports are encouraging. The internal snapping hip syndrome is produced by the iliopsoas tendon snapping over the iliopectineal eminence or the femoral head. The snapping phenomenon usually occurs with extension of the hip from a flexed position of more than 90 degree. Two different endoscopic techniques have been described to treat this condition. Iliopsoas tendon release at the level of the hip joint, with this technique the iliopsoas bursa is accessed through an anterior hip capsulotomy and is frequently referred to as a transcapsular release. The second technique is a release at the insertion of the iliopsoas tendon on the lesser trochanter, with this technique the iliospaos bursa is accessed directly. In every report the iliopsoas tendon release has been combined with arthroscopy of the hip joint. It has been

  2. First Record of the Arid-Land Termite Reticulitermes tibialis Banks, in Wisconsin

    Treesearch

    Rachel A. Arango

    2015-01-01

    During a survey of termites in Wisconsin, one colony was found from a different habitat than the remaining populations. This observation led to further genetic testing which resulted in a determination of Reticulitermes tibialis Banks. This is the first record of a termite species other than Reticulitermes flavipes (Kollar) to be...

  3. Tendon 'turnover lengthening' technique.

    PubMed

    Cerovac, S; Miranda, B H

    2013-11-01

    Tendon defect reconstruction is amongst the most technically challenging areas in hand surgery. Tendon substance deficiency reconstruction techniques include lengthening, grafting, two-stage reconstruction and tendon transfers, however each is associated with unique challenges over and above direct repair. We describe a novel 'turnover lengthening' technique for hand tendons that has successfully been applied to the repair of several cases, including a case of attritional flexor and traumatic extensor tendon rupture in two presented patients where primary tenorrhaphy was not possible. In both cases a good post-operative outcome was achieved, as the patients were happy having returned back to normal activities of daily living such that they were discharged 12 weeks post-operatively. Our technique avoids the additional morbidity and complications associated with grafting, transfers and two stage reconstructions. It is quick, simple and reproducible for defects not exceeding 3-4 cm, provides a means of immediate one stage reconstruction, no secondary donor site morbidity and does not compromise salvage by tendon transfer and/or two-stage reconstruction in cases of failure. To our knowledge no such technique has been previously been described to reconstruct such hand tendon defects. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  4. Rectus Femoris Tendon Calcification

    PubMed Central

    Zini, Raul; Panascì, Manlio; Papalia, Rocco; Franceschi, Francesco; Vasta, Sebastiano; Denaro, Vincenzo

    2014-01-01

    Background: Since it was developed, hip arthroscopy has become the favored treatment for femoroacetabular impingement. Due to recent considerable improvements, the indications for this technique have been widely extended. Injuries of the rectus femoris tendon origin, after an acute phase, could result in a chronic tendinopathy with calcium hydroxyapatite crystal deposition, leading to pain and loss of function. Traditionally, this condition is addressed by local injection of anesthetic and corticosteroids or, when conservative measures fail, by open excision of the calcific lesion by an anterior approach. Purpose: To assess whether arthroscopic excision of calcification of the proximal rectus is a safe and effective treatment. Study Design: Case series; Level of evidence, 4. Methods: Outcomes were studied from 6 top amateur athletes (age range, 30-43 years; mean, 32.6 years) affected by calcification of the proximal rectus who underwent arthroscopic excision of the calcification. Patients were preoperatively assessed radiographically, and diagnosis was confirmed by a 3-dimensional computed tomography scan. To evaluate the outcome, standardized hip rating scores were used pre- and postoperatively (at 6 and 12 months): the Hip disability and Osteoarthritis Outcome Score, Oxford Hip Score, and Modified Harris Hip Score. Moreover, visual analog scales (VAS) for pain, sport activity level (SAL), and activities of daily living (ADL) were also used. Results: One year after surgery, all patients reported satisfactory outcomes, with 3 of 6 rating their return-to-sport level as high as preinjury level, and the remaining 3 with a percentage higher than 80%. Five patients ranked their ability to carry on daily activities at 100%. Statistical analysis showed significant improvement of the Oxford Hip Score, the Modified Harris Hip Score, and all 3 VAS subscales (pain, SAL, and ADL) from pre- to latest postoperative assessment (P < .05). Conclusion: Arthroscopic excision of

  5. Scaffolds in Tendon Tissue Engineering

    PubMed Central

    Longo, Umile Giuseppe; Lamberti, Alfredo; Petrillo, Stefano; Maffulli, Nicola; Denaro, Vincenzo

    2012-01-01

    Tissue engineering techniques using novel scaffold materials offer potential alternatives for managing tendon disorders. Tissue engineering strategies to improve tendon repair healing include the use of scaffolds, growth factors, cell seeding, or a combination of these approaches. Scaffolds have been the most common strategy investigated to date. Available scaffolds for tendon repair include both biological scaffolds, obtained from mammalian tissues, and synthetic scaffolds, manufactured from chemical compounds. Preliminary studies support the idea that scaffolds can provide an alternative for tendon augmentation with an enormous therapeutic potential. However, available data are lacking to allow definitive conclusion on the use of scaffolds for tendon augmentation. We review the current basic science and clinical understanding in the field of scaffolds and tissue engineering for tendon repair. PMID:22190961

  6. Multiple tendon ruptures of unknown etiology.

    PubMed

    Axibal, Derek P; Anderson, John G

    2013-10-01

    Tendon ruptures are common findings in foot and ankle practice. The etiology of tendon ruptures tends to be multifactorial-usually due to a combination of trauma, effects of systemic diseases, adverse effects of medications, and obesity. We present an unusual case of right Achilles tendinitis, left Achilles tendon rupture, bilateral peroneus longus tendon rupture, and left peroneus brevis tendon rupture of unknown etiology. This case report highlights the need for research for other possible, lesser known etiologies of tendon pathology. Therapeutic, Level IV, Case Study.

  7. Tendon and ligament imaging

    PubMed Central

    Hodgson, R J; O'Connor, P J; Grainger, A J

    2012-01-01

    MRI and ultrasound are now widely used for the assessment of tendon and ligament abnormalities. Healthy tendons and ligaments contain high levels of collagen with a structured orientation, which gives rise to their characteristic normal imaging appearances as well as causing particular imaging artefacts. Changes to ligaments and tendons as a result of disease and injury can be demonstrated using both ultrasound and MRI. These have been validated against surgical and histological findings. Novel imaging techniques are being developed that may improve the ability of MRI and ultrasound to assess tendon and ligament disease. PMID:22553301

  8. Mechanical Strength of the Side-to-Side Tendon Attachment for Mismatched Tendon Sizes and Shapes

    PubMed Central

    Fridén, Jan; Tirrell, Timothy F.; Bhola, Siddharth; Lieber, Richard L.

    2015-01-01

    Summary Certain combinations are advised against in tendon transfers due to size or shape mismatches between donor and recipient tendons. In this study, ultimate load, stiffness and Young’s modulus were measured in two tendon-to-tendon attachments with intentionally mismatched donor and recipient tendons - pronator teres (PT)-to-extensor carpi radialis brevis (ECRB) and flexor carpi ulnaris (FCU)-to-extensor digitorum communis (EDC). FCU-EDC attachments failed at higher loads than PT-to-ECRB attachments but they had similar modulus and stiffness values. Ultimate tensile strength of the tendon attachments exceeded the maximum predicted contraction force of any of the affected muscles, with safety factors of 4x and 2x for the FCU-to-EDC and PT-to-ECRB constructs, respectively. This implies that size and shape mismatch should not be a contraindication to tendon attachment in transfers. Further, these safety factors strongly suggest that no postoperative immobilization of these attachments is necessary. PMID:24413573

  9. Lengthening osteotomy of the calcaneus and flexor digitorum longus tendon transfer in flexible flatfoot deformity improves talo-1st metatarsal-Index, clinical outcome and pedographic parameter.

    PubMed

    Richter, Martinus; Zech, Stefan

    2013-03-01

    Lengthening osteotomy of the calcaneus (LO) and flexor digitorum longus tendon (FDL) transfer to the navicular is one option for the treatment of flexible flatfoot deformity (FD). The aim of the study was to analyse the amount of correction and clinical outcome including pedographic assessment. In a prospective consecutive non-controlled clinical followup study, all patients with FD that were treated with LO and FDL from September 1st 2006 to August 31st, 2009 were included. Assessment was performed before surgery and at 2-year-followup including clinical examination (with staging of posterior tibialis insufficiency) weight bearing radiographs (Talo-1st metatarsal angles (TMT)), pedography (increased midfoot contact area and force) and Visual Analogue Scale Foot and Ankle (VAS FA). 112 feet in 102 patients were analysed (age, 57.6 (13-82), 42% male). In 12 feet (9%) wound healing delay without further surgical measures was registered. All patients achieved full weight bearing during the 7th postoperative week. Until followup, revision surgery was done in 3 patients (fusion calcaneocuboid joint (n=2), correction triple arthrodesis (n=1)). 101 feet (90%) completed 2-year-followup. TMT dorsoplantar/lateral/Index and VAS FA scores were increased, and posterior tibialis insufficiency stage, pedographic midfoot contact area and force percentage were decreased (each p<.05). All relevant parameters (stage of posterior tibialis insufficiency, TMT angles and Index, pedographic midfoot contact area and force percentage, VAS FA) were improved 2 years after LO and FDL transfer to the navicular in FD. The complication rate was low. This method allows safe and predictable correction. Copyright © 2012 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  10. Bilateral Patellar Tendon Rupture

    DTIC Science & Technology

    2009-07-01

    Bilateral patellar tendon rupture Military Medicine Radiology Corner, Volume 173, July, 2009...Radiology Corner Bilateral patellar tendon rupture (#37) Guarantor: 2dLt Ramon A. Riojas, USAF, MSC1 Contributors: 2dLt Ramon A. Riojas...with the abbreviated answer in the July 2009 issue. 1 The authors present a case of bilateral patellar tendon rupture in an active duty male exiting

  11. [Foster Modification of Full Tendon Transposition of Vertical Rectus Muscles for Sixth Nerve Palsy].

    PubMed

    Heede, Santa

    2018-04-11

    Since 1907 a variety of muscle transposition procedures for the treatment of abducens nerve palsy has been established internationally. Full tendon transposition of the vertical rectus muscle was initially described by O'Connor 1935 and then augmented by Foster 1997 with addition of posterior fixation sutures on the vertical rectus muscle. Full tendon transposition augmented by Foster belongs to the group of the most powerful surgical techniques to improve the abduction. Purpose of this study was to evaluate the results of full tendon vertical rectus transposition augmented with lateral fixation suture for patients with abducens nerve palsy. Full tendon transpositions of vertical rectus muscles augmented with posterior fixation suture was performed in 2014 on five patients with abducens nerve palsy. Two of the patients received Botox injections in the medial rectus muscle: one of them three months after the surgery and another during the surgery. One of the patients had a combined surgery of the horizontal muscles one year before. On three of the patients, who received a pure transposition surgery, the preoperative deviation at the distance (mean: + 56.6 pd; range: + 40 to + 80 pd) was reduced by a mean of 39.6 pd (range 34 to 50 pd), the abduction was improved by a mean of 3 mm (range 2 to 4 mm). The other two patients, who received besides the transposition procedure additional surgeries of the horizontal muscles, the preoperative deviation at the distance (+ 25 and + 126 pd respectively) was reduced by 20 and 81 pd respectively. The abduction was improved by 4 and 8 mm respectively. After surgery two patients developed a vertical deviation with a maximum of 4 pd. None of the patients had complications or signs of anterior segment ischemia. The elevation and/or depression was only marginally affected. There was no diplopia in up- or downgaze. Full tendon transposition of vertical rectus muscles, augmented with lateral posterior fixation suture is

  12. Between-day reliability of MyotonPRO for the non-invasive measurement of muscle material properties in the lower extremities of patients with a chronic spinal cord injury.

    PubMed

    Ko, Chang-Yong; Choi, Hyuk-Jae; Ryu, Jeicheong; Kim, Gyoosuk

    2018-05-17

    Measuring the muscle properties of patients with spinal cord injuries (SCIs) is important to better understand their biomechanical features. In this study, we sought to evaluate the between-day reliability of MyotonPRO, a handheld device that can measure muscle mechanical properties, and assess whether it is reliable to measure muscle properties over time in patients with SCI. Thirteen men with complete SCIs (age 53.9 ± 6.3 years, height 171.0 ± 5.2 cm, weight 66.1 ± 5.8 kg), and injury levels ranging from L1 to T12, were enrolled. Oscillation frequency; logarithmic decrement; dynamic stiffness; mechanical stress relaxation time; and creep of the biceps femoris, medial and lateral gastrocnemius, rectus femoris, tibialis anterior, and Achilles tendon were measured on consecutive days using MyotonPRO. The intraclass coefficient for most muscles and the Achilles tendon ranged from 0.53 to 0.99 for all parameters. The percentage standard error of the measurement for many parameters in most muscles and the Achilles tendon was less than 10%. Bland-Altman analysis showed a high agreement for all mechanical properties. No significant differences were observed in any muscle or Achilles tendon properties between days (all p > 0.05). These results indicate that the MyotonPRO is reliable for between-day measurements of the mechanical properties of lower limb muscles and Achilles tendon in patients with SCI. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Improvement of isometric dorsiflexion protocol for assessment of tibialis anterior muscle strength☆

    PubMed Central

    Siddiqi, Ariba; Arjunan, Sridhar P.; Kumar, Dinesh

    2015-01-01

    It is important to accurately estimate the electromyogram (EMG)/force relationship of triceps surae (TS) muscle for detecting strength deficit of tibalis anterior (TA) muscle. In literature, the protocol for recording EMG and force of dorsiflexion have been described, and the necessity for immobilizing the ankle has been explained. However, there is a significant variability of the results among researchers even though they report the fixation of the ankle. We have determined that toe extension can cause significant variation in the dorsiflexion force and EMG of TS and this can occur despite following the current guidelines which require immobilizing the ankle. The results also show that there was a large increase in the variability of the force and the RMS of EMG of TS when the toes were not strapped compared with when they were strapped. Thus, with the current guidelines, where there are no instructions regarding the necessity of strapping the toes, the EMG/force relationship of TS could be incorrect and give an inaccurate assessment of the dorsiflexor TA strength. In summary, • Current methodology to estimate the dorsiflexor TA strength with respect to the TS activity, emphasizing on ankle immobilization is insufficient to prevent large variability in the measurements. • Toe extension during dorsiflexion was found to be one source of variability in estimating the TA strength. • It is recommended that guidelines for recording force and EMG from TA and TS muscles should require the strapping of the toes along with the need for immobilizing the ankle. PMID:26150978

  14. Improvement of isometric dorsiflexion protocol for assessment of tibialis anterior muscle strength.

    PubMed

    Siddiqi, Ariba; Arjunan, Sridhar P; Kumar, Dinesh

    2015-01-01

    It is important to accurately estimate the electromyogram (EMG)/force relationship of triceps surae (TS) muscle for detecting strength deficit of tibalis anterior (TA) muscle. In literature, the protocol for recording EMG and force of dorsiflexion have been described, and the necessity for immobilizing the ankle has been explained. However, there is a significant variability of the results among researchers even though they report the fixation of the ankle. We have determined that toe extension can cause significant variation in the dorsiflexion force and EMG of TS and this can occur despite following the current guidelines which require immobilizing the ankle. The results also show that there was a large increase in the variability of the force and the RMS of EMG of TS when the toes were not strapped compared with when they were strapped. Thus, with the current guidelines, where there are no instructions regarding the necessity of strapping the toes, the EMG/force relationship of TS could be incorrect and give an inaccurate assessment of the dorsiflexor TA strength. In summary, •Current methodology to estimate the dorsiflexor TA strength with respect to the TS activity, emphasizing on ankle immobilization is insufficient to prevent large variability in the measurements.•Toe extension during dorsiflexion was found to be one source of variability in estimating the TA strength.•It is recommended that guidelines for recording force and EMG from TA and TS muscles should require the strapping of the toes along with the need for immobilizing the ankle.

  15. Optimization of human tendon tissue engineering: peracetic acid oxidation for enhanced reseeding of acellularized intrasynovial tendon.

    PubMed

    Woon, Colin Y L; Pridgen, Brian C; Kraus, Armin; Bari, Sina; Pham, Hung; Chang, James

    2011-03-01

    Tissue engineering of human flexor tendons combines tendon scaffolds with recipient cells to create complete cell-tendon constructs. Allogenic acellularized human flexor tendon has been shown to be a useful natural scaffold. However, there is difficulty repopulating acellularized tendon with recipient cells, as cell penetration is restricted by a tightly woven tendon matrix. The authors evaluated peracetic acid treatment in optimizing intratendinous cell penetration. Cadaveric human flexor tendons were harvested, acellularized, and divided into experimental groups. These groups were treated with peracetic acid in varying concentrations (2%, 5%, and 10%) and for varying time periods (4 and 20 hours) to determine the optimal treatment protocol. Experimental tendons were analyzed for differences in tendon microarchitecture. Additional specimens were reseeded by incubation in a fibroblast cell suspension at 1 × 10(6) cells/ml. This group was then analyzed for reseeding efficacy. A final group underwent biomechanical studies for strength. The optimal treatment protocol comprising peracetic acid at 5% concentration for 4 hours produced increased scaffold porosity, improving cell penetration and migration. Treated scaffolds did not show reduced collagen or glycosaminoglycan content compared with controls (p = 0.37 and p = 0.65, respectively). Treated scaffolds were cytotoxic to neither attached cells nor the surrounding cell suspension. Treated scaffolds also did not show inferior ultimate tensile stress or elastic modulus compared with controls (p = 0.26 and p = 0.28, respectively). Peracetic acid treatment of acellularized tendon scaffolds increases matrix porosity, leading to greater reseeding. It may prove to be an important step in tissue engineering of human flexor tendon using natural scaffolds.

  16. Influence of the initial rupture size and tendon subregion on three-dimensional biomechanical properties of single-row and double-row rotator cuff reconstructions.

    PubMed

    Lorbach, O; Pape, D; Raber, F; Busch, L C; Kohn, D; Kieb, M

    2012-11-01

    Influence of the initial rotator cuff tear size and of different subregions of the SSP tendon on the cyclic loading behavior of a modified single-row reconstruction compared to a suture-bridging double-row repair. Artificial tears (25 and 35 mm) were created in the rotator cuff of 24 human cadaver shoulders. The reconstructions were performed as a single-row repair (SR) using a modified suture configuration or a suture-bridge double-row repair (DR). Radiostereometric analysis was used under cyclic loading (50 cycles, 10–180 N, 10–250 N) to calculate cyclic displacement in three different planes (anteroposterior (x), craniocaudal (y) and mediolateral (z) level). Cyclic displacement was recorded, and differences in cyclic displacement of the anterior compared to the posterior subregions of the tendon were calculated. In small-to-medium tears (25 mm) and medium-to-large tears (35 mm), significant lower cyclic displacement was seen for the SR-reconstruction compared to the DR-repair at 180 N (p ≤ 0.0001; p = 0.001) and 250 N (p = 0.001; p = 0.007) in the x-level. These results were confirmed in the y-level at 180 N (p = 0.001; p = 0.0022) and 250 N (p = 0.005; p = 0.0018). Comparison of the initial tear sizes demonstrated significant differences in cyclic displacement for the DR technique in the x-level at 180 N (p = 0.002) and 250 N (p = 0.004). Comparison of the anterior versus the posterior subregion of the tendon revealed significant lower gap formation in the posterior compared to the anterior subregions in the x-level for both tested rotator cuff repairs (p ≤ 0.05). The tested single-row repair using a modified suture configuration achieved superior results in three-dimensional measurements of cyclic displacement compared to the tested double-row suture-bridge repair. The results were dependent on the initial rupture size of the rotator cuff tear. Furthermore, significant differences were found between tendon subregions of the rotator cuff with

  17. The distal biceps tendon.

    PubMed

    Schmidt, Christopher C; Jarrett, Claudius D; Brown, Brandon T

    2013-04-01

    Distal biceps tendon ruptures continue to be an important injury seen and treated by upper extremity surgeons. Since the mid-1980s, the emphasis has been placed on techniques that limit complications or improve initial tendon-to-bone fixation strength. Recently, basic science research has expanded the knowledge base regarding the biceps tendon structure, footprint anatomy, and biomechanics. Clinical data have further delineated the results of conservative and surgical management of both partial and complete tears in acute or chronic states. The current literature on the distal biceps tendon is described in detail. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  18. Predictors and effects of patellofemoral pain following hamstring-tendon ACL reconstruction.

    PubMed

    Culvenor, Adam G; Collins, Natalie J; Vicenzino, Bill; Cook, Jill L; Whitehead, Timothy S; Morris, Hayden G; Crossley, Kay M

    2016-07-01

    Patellofemoral pain is a frequent and troublesome complication following anterior cruciate ligament reconstruction (ACLR), irrespective of graft source. Yet, little is known about the factors associated with patellofemoral pain following hamstring-tendon ACLR. Retrospective analysis of potential patellofemoral pain predictors, and cross-sectional analysis of possible patellofemoral pain consequences. Potential predictors (pre-injury patellofemoral pain and activity level, concomitant patellofemoral cartilage damage and meniscectomy, age, sex, and surgical delay) and consequences (hopping performance, quality of life, kinesiophobia, and return to sport rates and attitudes) of patellofemoral pain 12 months following hamstring-tendon ACLR were assessed in 110 participants using univariate and multivariate analyses. Thirty-three participants (30%) had patellofemoral pain at 12 months post-ACLR. Older age at the time of ACLR was the only predictor of post-operative patellofemoral pain. Following ACLR, those with patellofemoral pain had a higher body mass index, and worse physical performance, quality of life, kinesiophobia and return to sport attitudes. Patellofemoral pain has a significant burden on individuals 12 months following hamstring-tendon ACLR. Clinicians need to be cognisant of patellofemoral pain, particularly in older individuals and those with a higher body mass index. The importance of considering psychological factors that are not typically addressed during ACLR rehabilitation, such as kinesiophobia, quality of life and return to sport attitudes is emphasised. Copyright © 2016. Published by Elsevier Ltd.

  19. Tendon Driven Finger Actuation System

    NASA Technical Reports Server (NTRS)

    Ihrke, Chris A. (Inventor); Reich, David M. (Inventor); Bridgwater, Lyndon (Inventor); Linn, Douglas Martin (Inventor); Askew, Scott R. (Inventor); Diftler, Myron A. (Inventor); Platt, Robert (Inventor); Hargrave, Brian (Inventor); Valvo, Michael C. (Inventor); Abdallah, Muhammad E. (Inventor); hide

    2013-01-01

    A humanoid robot includes a robotic hand having at least one finger. An actuation system for the robotic finger includes an actuator assembly which is supported by the robot and is spaced apart from the finger. A tendon extends from the actuator assembly to the at least one finger and ends in a tendon terminator. The actuator assembly is operable to actuate the tendon to move the tendon terminator and, thus, the finger.

  20. Surgical Management of Simultaneous Anterior Cruciate Ligament and Patellar Tendon Ruptures: A Systematic Review.

    PubMed

    Meheux, Carlos J; Jack, Robert A; McCulloch, Patrick C; Lintner, David M; Harris, Joshua D

    2017-12-28

    This study performs a systematic review to determine (1) if a significant difference exists in return to preinjury activity level between one- and two-stage treatment of combined anterior cruciate ligament (ACL) and patellar tendon (PT) tears; and (2) if a significant difference exists in the number of postoperative complications between the two differing surgical treatment approaches. A systematic review was performed using Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines and registered on PROSPERO. MEDLINE, Cochrane Central Register of Controlled Trials, SCOPUS, and Sport Discus were searched for English language level I-IV evidence studies on either one- (simultaneous) or two-stage (sequential) surgical treatment of simultaneously sustained ipsilateral ACL and PT tears. The approach to initial evaluation, diagnosis, treatment, and outcomes were qualitatively analyzed. Methodological quality assessment of all included studies was completed using the Methodological Index for Non-randomized Studies (MINORS). The Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) tool was used to assess quality of evidence and provide strength of recommendation. Statistical analyses were done using Fischer's exact test. Eleven articles (18 patients; 83% males; mean age, 31.1 ± 10.1 years; mean follow-up, 2.2 ± 1.7 years; and mean MINORS 7.8/16) were analyzed. Eight patients had a one-stage procedure (primary PT repair and ACL reconstruction), and 10 patients underwent a two-stage procedure (primary PT repair first followed by ACL reconstruction) with mean 28 ± 45.7 weeks (5 weeks-3 years) between surgeries. The rate for return to preinjury activity level after surgery was not significantly different between one- (88%) and two-stage (100%) ( p  = 0.444). There was a significantly higher complication rate ( p  = 0.023) in the one-stage (stiffness, instability, and patella baja) versus two

  1. Changes in Achilles tendon mechanical properties following eccentric heel drop exercise are specific to the free tendon.

    PubMed

    Obst, S J; Newsham-West, R; Barrett, R S

    2016-04-01

    Mechanical loading of the Achilles tendon during isolated eccentric contractions could induce immediate and region-dependent changes in mechanical properties. Three-dimensional ultrasound was used to examine the immediate effect of isolated eccentric exercise on the mechanical properties of the distal (free tendon) and proximal (gastrocnemii) regions of the Achilles tendon. Participants (n = 14) underwent two testing sessions in which tendon measurements were made at rest and during a 30% and 70% isometric plantar flexion contractions immediately before and after either: (a) 3 × 15 eccentric heel drops or (b) 10-min rest. There was a significant time-by-session interaction for free tendon length and strain for all loading conditions (P < 0.05). Pairwise comparisons revealed a significant increase in free tendon length and strain at all contraction intensities after eccentric exercise (P < 0.05). There was no significant time-by-session interaction for the gastrocnemii (medial or lateral) aponeurosis or tendon for any of the measured parameters. Immediate changes in Achilles tendon mechanical properties were specific to the free tendon and consistent with changes due to mechanical creep. These findings suggest that the mechanical properties of the free tendon may be more vulnerable to change with exercise compared with the gastrocnemii aponeurosis or tendon. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Mechanisms of tendon injury and repair

    PubMed Central

    Thomopoulos, Stavros; Parks, William C.; Rifkin, Daniel B.; Derwin, Kathleen A.

    2015-01-01

    Tendon disorders are common and lead to significant disability, pain, healthcare cost, and lost productivity. A wide range of injury mechanisms exist leading to tendinopathy or tendon rupture. Tears can occur in healthy tendons that are acutely overloaded (e.g., during a high speed or high impact event) or lacerated (e.g., a knife injury). Tendinitis or tendinosis can occur in tendons exposed to overuse conditions (e.g., an elite swimmer’s training regimen) or intrinsic tissue degeneration (e.g., age-related degeneration). The healing potential of a torn or pathologic tendon varies depending on anatomic location (e.g., Achilles vs. rotator cuff) and local environment (e.g., intrasynovial vs. extrasynovial). Although healing occurs to varying degrees, in general healing of repaired tendons follows the typical wound healing course, including an early inflammatory phase, followed by proliferative and remodeling phases. Numerous treatment approaches have been attempted to improve tendon healing, including growth factor- and cell-based therapies and rehabilitation protocols. This review will describe the current state of knowledge of injury and repair of the three most common tendinopathies-- flexor tendon lacerations, Achilles tendon rupture, and rotator cuff disorders-- with a particular focus on the use of animal models for understanding tendon healing. PMID:25641114

  3. Magnetotherapy: The quest for tendon regeneration.

    PubMed

    Pesqueira, Tamagno; Costa-Almeida, Raquel; Gomes, Manuela E

    2018-05-09

    Tendons are mechanosensitive tissues that connect and transmit the forces generated by muscles to bones by allowing the conversion of mechanical input into biochemical signals. These physical forces perform the fundamental work of preserving tendon homeostasis assuring body movements. However, overloading causes tissue injuries, which leads us to the field of tendon regeneration. Recently published reviews have broadly shown the use of biomaterials and different strategies to attain tendon regeneration. In this review, our focus is the use of magnetic fields as an alternative therapy, which has demonstrated clinical relevance in tendon medicine because of their ability to modulate cell fate. Yet the underlying cellular and molecular mechanisms still need to be elucidated. While providing a brief outlook about specific signalling pathways and intracellular messengers as framework in play by tendon cells, application of magnetic fields as a subcategory of physical forces is explored, opening up a compelling avenue to enhance tendon regeneration. We outline here useful insights on the effects of magnetic fields both at in vitro and in vivo levels, particularly on the expression of tendon genes and inflammatory cytokines, ultimately involved in tendon regeneration. Subsequently, the potential of using magnetically responsive biomaterials in tendon tissue engineering is highlighted and future directions in magnetotherapy are discussed. © 2018 Wiley Periodicals, Inc.

  4. [Arthroscopic reconstruction of anterior cruciate ligament with press-fit technique].

    PubMed

    Halder, A M

    2010-08-01

    Problems related to the use of interference screws for fixation of bone-patellar tendon-bone grafts for anterior cruciate ligament (ACL) replacement have led to increasing interest in press-fit techniques. Most of the described techniques use press-fit fixation on either the femoral or tibial side. Therefore an arthroscopic technique was developed which achieves bone-patellar tendon-bone graft fixation by press-fit on both sides without the need for supplemental fixation material. The first consecutive 40 patients were examined clinically with a KT-1000 arthrometer and radiologically after a mean of 28.7 months (range 20-40 months) postoperatively. The mean difference in side-to-side laxity was 1.3 mm (SD 2.2 mm) and the results according to the International Knee Documentation Committee (IKDC) score were as follows: 7 A, 28 B, 5 C, 0 D. The presented press-fit technique avoids all complications related to the use of interference screws. It achieves primary stable fixation of the bone-patellar tendon-bone graft thereby allowing early functional rehabilitation. However, fixation strength depends on bone quality and the arthroscopic procedure is demanding. The results showed reliable stabilization of the operated knees.

  5. Experimental evaluation of multiscale tendon mechanics.

    PubMed

    Fang, Fei; Lake, Spencer P

    2017-07-01

    Tendon's primary function is a mechanical link between muscle and bone. The hierarchical structure of tendon and specific compositional constituents are believed to be critical for proper mechanical function. With increased appreciation for tendon importance and the development of various technological advances, this review paper summarizes recent experimental approaches that have been used to study multiscale tendon mechanics, includes an overview of studies that have evaluated the role of specific tissue constituents, and also proposes challenges/opportunities facing tendon study. Tendon has been demonstrated to have specific structural characteristics (e.g., multi-level hierarchy, crimp pattern, helix) and complex mechanical properties (e.g., non-linearity, anisotropy, viscoelasticity). Physical mechanisms including uncrimping, fiber sliding, and collagen reorganization have been shown to govern tendon mechanical responses under both static and dynamic loading. Several tendon constituents with relatively small quantities have been suggested to play a role in its mechanics, although some results are conflicting. Further research should be performed to understand the interplay and communication of tendon mechanical properties across levels of the hierarchical structure, and further show how each of these components contribute to tendon mechanics. The studies summarized and discussed in this review have helped elucidate important aspects of multiscale tendon mechanics, which is a prerequisite for analyzing stress/strain transfer between multiple scales and identifying key principles of mechanotransduction. This information could further facilitate interpreting the functional diversity of tendons from different species, different locations, and even different developmental stages, and then better understand and identify fundamental concepts related to tendon degeneration, disease, and healing. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc

  6. Achilles Tendon Rupture

    MedlinePlus

    ... also help the muscle and tendon absorb more force and prevent injury. Vary your exercises. Alternate high-impact sports, such as running, with low-impact sports, such as walking, biking or swimming. Avoid activities that place excessive stress on your Achilles tendons, such as hill ...

  7. Collagen fibrils in functionally distinct tendons have differing structural responses to tendon rupture and fatigue loading.

    PubMed

    Herod, Tyler W; Chambers, Neil C; Veres, Samuel P

    2016-09-15

    In this study we investigate relationships between the nanoscale structure of collagen fibrils and the macroscale functional response of collagenous tissues. To do so, we study two functionally distinct classes of tendons, positional tendons and energy storing tendons, using a bovine forelimb model. Molecular-level assessment using differential scanning calorimetry (DSC), functional crosslink assessment using hydrothermal isometric tension (HIT) analysis, and ultrastructural assessment using scanning electron microscopy (SEM) were used to study undamaged, ruptured, and cyclically loaded samples from the two tendon types. HIT indicated differences in both crosslink type and crosslink density, with flexor tendons having more thermally stable crosslinks than the extensor tendons (higher TFmax of >90 vs. 75.1±2.7°C), and greater total crosslink density than the extensor tendons (higher t1/2 of 11.5±1.9 vs. 3.5±1.0h after NaBH4 treatment). Despite having a lower crosslink density than flexor tendons, extensor tendons were significantly stronger (37.6±8.1 vs. 23.1±7.7MPa) and tougher (14.3±3.6 vs. 6.8±3.4MJ/m(3)). SEM showed that collagen fibrils in the tougher, stronger extensor tendons were able to undergo remarkable levels of plastic deformation in the form of discrete plasticity, while those in the flexor tendons were not able to plastically deform. When cyclically loaded, collagen fibrils in extensor tendons accumulated fatigue damage rapidly in the form of kink bands, while those in flexor tendons did not accumulate significant fatigue damage. The results demonstrate that collagen fibrils in functionally distinct tendons respond differently to mechanical loading, and suggests that fibrillar collagens may be subject to a strength vs. fatigue resistance tradeoff. Collagen fibrils-nanoscale biological cables-are the fundamental load-bearing elements of all structural human tissues. While all collagen fibrils share common features, such as being composed of a

  8. Anterior Segment Ischemia after Strabismus Surgery

    PubMed Central

    Göçmen, Emine Seyhan; Atalay, Yonca; Evren Kemer, Özlem; Sarıkatipoğlu, Hikmet Yavuz

    2017-01-01

    A 46-year-old male patient was referred to our clinic with complaints of diplopia and esotropia in his right eye that developed after a car accident. The patient had right esotropia in primary position and abduction of the right eye was totally limited. Primary deviation was over 40 prism diopters at near and distance. The patient was diagnosed with sixth nerve palsy and 18 months after trauma, he underwent right medial rectus muscle recession. Ten months after the first operation, full-thickness tendon transposition of the superior and inferior rectus muscles (with Foster suture) was performed. On the first postoperative day, slit-lamp examination revealed corneal edema, 3+ cells in the anterior chamber and an irregular pupil. According to these findings, the diagnosis was anterior segment ischemia. Treatment with 0.1/5 mL topical dexamethasone drops (16 times/day), cyclopentolate hydrochloride drops (3 times/day) and 20 mg oral fluocortolone (3 times/day) was initiated. After 1 week of treatment, corneal edema regressed and the anterior chamber was clean. Topical and systemic steroid treatment was gradually discontinued. At postoperative 1 month, the patient was orthophoric and there were no pathologic symptoms besides the irregular pupil. Anterior segment ischemia is one of the most serious complications of strabismus surgery. Despite the fact that in most cases the only remaining sequel is an irregular pupil, serious circulation deficits could lead to phthisis bulbi. Clinical properties of anterior segment ischemia should be well recognized and in especially risky cases, preventative measures should be taken. PMID:28182149

  9. Bioreactor design for tendon/ligament engineering.

    PubMed

    Wang, Tao; Gardiner, Bruce S; Lin, Zhen; Rubenson, Jonas; Kirk, Thomas B; Wang, Allan; Xu, Jiake; Smith, David W; Lloyd, David G; Zheng, Ming H

    2013-04-01

    Tendon and ligament injury is a worldwide health problem, but the treatment options remain limited. Tendon and ligament engineering might provide an alternative tissue source for the surgical replacement of injured tendon. A bioreactor provides a controllable environment enabling the systematic study of specific biological, biochemical, and biomechanical requirements to design and manufacture engineered tendon/ligament tissue. Furthermore, the tendon/ligament bioreactor system can provide a suitable culture environment, which mimics the dynamics of the in vivo environment for tendon/ligament maturation. For clinical settings, bioreactors also have the advantages of less-contamination risk, high reproducibility of cell propagation by minimizing manual operation, and a consistent end product. In this review, we identify the key components, design preferences, and criteria that are required for the development of an ideal bioreactor for engineering tendons and ligaments.

  10. [Reconstruction of the extensor pollicis longus tendon by transposition of the extensor indicis tendon].

    PubMed

    Loos, A; Kalb, K; Van Schoonhoven, J; Landsleitner Dagger, B

    2003-12-01

    Rupture of the extensor pollicis longus-tendon (EPL) is a frequent complication after distal radius fractures. Other traumatic and non-traumatic reasons for this tendon lesion are known, including a theory about a disorder in the blood supply to the tendon itself. We examined 40 patients after reconstruction of the EPL-tendon in a mean follow-up time of 30 months. All patients were clinically examined and a DASH questionnaire was answered by all patients. The method to reconstruct the EPL-tendon was the transposition of the extensor indicis-tendon. After the operations the thumb was put in a splint for four weeks in a "hitch-hiker's-position". 31 ruptures of the tendon (77.5 %) were a result of trauma. In 20 of them (50 %) a distal radius fracture had occurred. Clinical examination included measurements of the movement of the thumb- and index-finger joints, the grip strength and the maximal span of the hand. Significant differences were not found. The isolated extension of the index finger was possible in all patients. But it was reduced in ten cases which represent 25 %. Our results were evaluated by the Geldmacher score to evaluate the reconstruction of the EPL-tendon. 20 % excellent, 65 % good, 12.5 % fair and 2.5 % poor results were reached. The Geldmacher score was used critically. We suggest its modification for the evaluation of thumb abduction. The DASH score reached a functional value of ten points which represents a very good result. In conclusion the extensor indicis-transposition is a safe method to reconstruct the EPL-tendon. Its substantial advantage is taking a healthy muscle as the motor, thereby avoiding the risk of using a degenerated muscle in late tendon reconstruction. A powerful extension of the index finger will be maintained by physical education. Generally, the loss of the extension of the index finger is negligible. It does not disturb the patients. But it has to be discussed with the patient before the operation.

  11. Structure-function relationships in tendons: a review

    PubMed Central

    Benjamin, M; Kaiser, E; Milz, S

    2008-01-01

    The purpose of the current review is to highlight the structure-function relationship of tendons and related structures to provide an overview for readers whose interest in tendons needs to be underpinned by anatomy. Because of the availability of several recent reviews on tendon development and entheses, the focus of the current work is primarily directed towards what can best be described as the ‘tendon proper’ or the ‘mid-substance’ of tendons. The review covers all levels of tendon structure from the molecular to the gross and deals both with the extracellular matrix and with tendon cells. The latter are often called ‘tenocytes’ and are increasingly recognized as a defined cell population that is functionally and phenotypically distinct from other fibroblast-like cells. This is illustrated by their response to different types of mechanical stress. However, it is not only tendon cells, but tendons as a whole that exhibit distinct structure-function relationships geared to the changing mechanical stresses to which they are subject. This aspect of tendon biology is considered in some detail. Attention is briefly directed to the blood and nerve supply of tendons, for this is an important issue that relates to the intrinsic healing capacity of tendons. Structures closely related to tendons (joint capsules, tendon sheaths, pulleys, retinacula, fat pads and bursae) are also covered and the concept of a ‘supertendon’ is introduced to describe a collection of tendons in which the function of the whole complex exceeds that of its individual members. Finally, attention is drawn to the important relationship between tendons and fascia, highlighted by Wood Jones in his concept of an ‘ectoskeleton’ over half a century ago – work that is often forgotten today. PMID:18304204

  12. Simultaneous bilateral distal biceps tendon repair: case report.

    PubMed

    Storti, Thiago Medeiros; Paniago, Alexandre Firmino; Faria, Rafael Salomon Silva

    2017-01-01

    Simultaneous bilateral rupture of the distal biceps tendon is a rare clinical entity, seldom reported in the literature and with unclear therapeutic setting. The authors report the case of a 39-year-old white man who suffered a simultaneous bilateral rupture while working out. When weightlifting with elbows at 90° of flexion, he suddenly felt pain on the anterior aspect of the arms, coming for evaluation after two days. He presented bulging contour of the biceps muscle belly and ecchymosis in the antecubital fossa, extending distally to the medial aspect of the forearm, as well as a marked decrease of supination strength and pain in active elbow flexion. MRI confirmed the rupture with retraction of the distal biceps bilaterally. The authors opted for performing the tendon repairs simultaneously through the double incision technique and fixation to the bicipital tuberosity with anchors. The patient progressed quite well, with full return to labor and sports activities, being satisfied with the result after two years of surgery. In the literature search, few reports of simultaneous bilateral rupture of the distal biceps were retrieved, with only one treated in the acute phase of injury. Therefore, the authors consider this procedure to be a good option to solve this complex condition.

  13. [Secondary tendon reconstruction on the thumb].

    PubMed

    Bickert, B; Kremer, T; Kneser, U

    2016-12-01

    Closed tendon ruptures of the thumb that require secondary reconstruction can affect the extensor pollicis longus (EPL), extensor pollicis brevis (EPB) and flexor pollicis longus (FPL) tendons. Treatment of rupture of the EPB tendon consists of refixation to the bone and temporary transfixation of the joint. In the case of preexisting or posttraumatic arthrosis, definitive arthrodesis of the thumb is the best procedure. Closed ruptures of the EPL and FPL tendons at the wrist joint cannot be treated by direct tendon suture. Rupture of the EPL tendon occurs after distal radius fractures either due to protruding screws or following conservative treatment especially in undisplaced fractures. Transfer of the extensor indicis tendon to the distal EPL stump is a good option and free interposition of the palmaris longus tendon is a possible alternative. The tension should be adjusted to slight overcorrection, which can be checked intraoperatively by performing the tenodesis test. Closed FPL ruptures at the wrist typically occur 3-6 months after osteosynthesis of distal radius fractures with palmar plates and are mostly characterized by crepitation and pain lasting for several weeks. They can be prevented by premature plate removal, synovectomy and carpal tunnel release. For treatment of a ruptured FPL tendon in adult patients the options for tendon reconstruction should be weighed up against the less complicated tenodesis or arthrodesis of the thumb interphalangeal joint.

  14. Tendon neuroplastic training: changing the way we think about tendon rehabilitation: a narrative review

    PubMed Central

    Rio, Ebonie; Kidgell, Dawson; Moseley, G Lorimer; Docking, Sean; Purdam, Craig; Cook, Jill

    2016-01-01

    Tendinopathy can be resistant to treatment and often recurs, implying that current treatment approaches are suboptimal. Rehabilitation programmes that have been successful in terms of pain reduction and return to sport outcomes usually include strength training. Muscle activation can induce analgesia, improving self-efficacy associated with reducing one's own pain. Furthermore, strength training is beneficial for tendon matrix structure, muscle properties and limb biomechanics. However, current tendon rehabilitation may not adequately address the corticospinal control of the muscle, which may result in altered control of muscle recruitment and the consequent tendon load, and this may contribute to recalcitrance or symptom recurrence. Outcomes of interest include the effect of strength training on tendon pain, corticospinal excitability and short interval cortical inhibition. The aims of this concept paper are to: (1) review what is known about changes to the primary motor cortex and motor control in tendinopathy, (2) identify the parameters shown to induce neuroplasticity in strength training and (3) align these principles with tendon rehabilitation loading protocols to introduce a combination approach termed as tendon neuroplastic training. Strength training is a powerful modulator of the central nervous system. In particular, corticospinal inputs are essential for motor unit recruitment and activation; however, specific strength training parameters are important for neuroplasticity. Strength training that is externally paced and akin to a skilled movement task has been shown to not only reduce tendon pain, but modulate excitatory and inhibitory control of the muscle and therefore, potentially tendon load. An improved understanding of the methods that maximise the opportunity for neuroplasticity may be an important progression in how we prescribe exercise-based rehabilitation in tendinopathy for pain modulation and potentially restoration of the corticospinal

  15. ANTERIOR CRUCIATE LIGAMENT INJURY: TREATMENT AND REHABILITATION. CURRENT PERSPECTIVES AND TRENDS

    PubMed Central

    Arliani, Gustavo Gonçalves; Astur, Diego da Costa; Kanas, Michel; Kaleka, Camila Cohen; Cohen, Moises

    2015-01-01

    Objective: The aim of this study was to evaluate the procedures used by knee surgeons in Brazil for treating and rehabilitating anterior cruciate ligament injuries. Methods: A questionnaire consisting of 21 closed questions was developed, addressing topics relating to treatment and rehabilitation after anterior cruciate ligament reconstruction. The questionnaire was applied to Brazilian knee surgeons during the three days of the 42nd Brazilian Congress of Orthopedics and Traumatology in 2010. Results: A total of 226 surgeons filled out the questionnaire completely. The most commonly used types of graft were hamstrings tendons and the central third of the ipsilateral patellar tendon, which were used by 82.3% and 53.5% of the sample, respectively. The technique of reconstruction with a single transtibial band was the first preference and was used by 66.4% of the participants. A period of 1 to 4 weeks between injury and surgical procedure was considered ideal by most participants (52.65%). Complaints from patients that the knee was ‘giving way’ or unstable and presence of a positive pivot shift maneuver were the most decisive factors considered in making the decision to operate the patient. Patient satisfaction and absence of complaints of instability during the postoperative period were the criteria deemed to be most important for the surgery to be considered a success. Conclusions: There are clearly evolving trends in treating and rehabilitating the anterior cruciate ligament in Brazil. However, more prospective controlled studies are needed in order to evaluate the clinical and scientific benefits of these trends. PMID:27042620

  16. Bioreactor Design for Tendon/Ligament Engineering

    PubMed Central

    Wang, Tao; Gardiner, Bruce S.; Lin, Zhen; Rubenson, Jonas; Kirk, Thomas B.; Wang, Allan; Xu, Jiake

    2013-01-01

    Tendon and ligament injury is a worldwide health problem, but the treatment options remain limited. Tendon and ligament engineering might provide an alternative tissue source for the surgical replacement of injured tendon. A bioreactor provides a controllable environment enabling the systematic study of specific biological, biochemical, and biomechanical requirements to design and manufacture engineered tendon/ligament tissue. Furthermore, the tendon/ligament bioreactor system can provide a suitable culture environment, which mimics the dynamics of the in vivo environment for tendon/ligament maturation. For clinical settings, bioreactors also have the advantages of less-contamination risk, high reproducibility of cell propagation by minimizing manual operation, and a consistent end product. In this review, we identify the key components, design preferences, and criteria that are required for the development of an ideal bioreactor for engineering tendons and ligaments. PMID:23072472

  17. Double-Bundle Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon Hybrid Grafts in Patients Over 40 Years of Age: Comparisons Between Different Age Groups.

    PubMed

    Nishio, Yusuke; Kondo, Eiji; Onodera, Jun; Onodera, Tomohiro; Yagi, Tomonori; Iwasaki, Norimasa; Yasuda, Kazunori

    2018-05-01

    Several recent studies have reported that favorable clinical results and a high level of patient satisfaction can generally be obtained with no increased risk of complications after single-bundle anterior cruciate ligament (ACL) reconstruction performed in patients >40 years of age. However, no studies have yet clarified the age-based differences in clinical outcomes after double-bundle reconstruction. To compare clinical outcomes after double-bundle ACL reconstruction using hamstring tendon hybrid grafts between patients in 2 different age groups: ≥40 years and <40 years. Cohort study; Level of evidence, 3. A retrospective study was conducted using 96 patients (48 men, 48 women ; mean age, 37 years) who underwent unilateral ACL reconstruction between 2008 and 2011. These patients were divided into 2 groups: group M included patients ≥40 years of age (n = 40 patients), and group Y included patients <40 years of age (n = 56 patients). All patients underwent the same anatomic double-bundle ACL reconstruction procedure. Clinical outcomes were evaluated at 2 years after surgery. Tunnel enlargement was also evaluated by computed digital radiography at 1 week and 2 years after surgery. Mean postoperative side-to-side differences in anterior laxity were 0.5 ± 1.9 mm and 1.2 ± 1.5 mm in groups M and Y, respectively; there was a significant difference between the 2 groups ( P = .039). There were no significant differences between the groups in Lysholm knee scores, International Knee Documentation Committee (IKDC) scores, or peak muscle torque of the hamstring. On the other hand, peak muscle torque of the quadriceps was significantly lower in group M (81%) than in group Y (89%) ( P = .025). With respect to femoral tunnel enlargement, the posterolateral tunnel in group M was significantly larger than that in group Y on anteroposterior and lateral radiographs ( P = .015 and P = .002, respectively). Equivalent clinical outcomes were seen between the 2 age groups after

  18. Bilateral spinal anterior horn lesions in acute motor axonal neuropathy.

    PubMed

    Sawada, Daisuke; Fujii, Katsunori; Misawa, Sonoko; Shiohama, Tadashi; Fukuhara, Tomoyuki; Fujita, Mayuko; Kuwabara, Satoshi; Shimojo, Naoki

    2018-05-28

    Guillain-Barré syndrome is an acute immune-mediated peripheral polyneuropathy. Neuroimaging findings from patients with this syndrome have revealed gadolinium enhancement in the cauda equina and in the anterior and posterior nerve roots, but intra-spinal lesions have never been described. Herein, we report, for the first time, bilateral spinal anterior horn lesions in a patient with an acute motor axonal neuropathy form of Guillain-Barré syndrome. The patient was a previously healthy 13-year-old Japanese girl, who exhibited acute-onset flaccid tetraplegia and loss of tendon reflexes. Nerve conduction studies revealed motor axonal damage, leading to the diagnosis of acute motor axonal neuropathy. Notably, spinal magnetic resonance imaging revealed bilateral anterior horn lesions on T2-weighted imaging at the Th11-12 levels, as well as gadolinium enhancement of the cauda equina and anterior and posterior nerve roots. The anterior horn lesions were most prominent on day 18, and their signal intensity declined thereafter. Although intravenous treatment with immunoglobulins was immediately administered, the motor function was not completely regained. We propose that anterior spinal lesions might be responsible for the prolonged neurological disability of patients with Guillain-Barré syndrome, possibly produced by retrograde progression from the affected anterior nerve roots to the intramedullary roots, and the anterior horn motor neurons. Copyright © 2018 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  19. Conditioning of the Achilles tendon via ankle exercise improves correlations between sonographic measures of tendon thickness and body anthropometry.

    PubMed

    Wearing, Scott C; Grigg, Nicole L; Hooper, Sue L; Smeathers, James E

    2011-05-01

    Although conditioning is routinely used in mechanical tests of tendon in vitro, previous in vivo research evaluating the influence of body anthropometry on Achilles tendon thickness has not considered its potential effects on tendon structure. This study evaluated the relationship between Achilles tendon thickness and body anthropometry in healthy adults both before and after resistive ankle plantarflexion exercise. A convenience sample of 30 healthy male adults underwent sonographic examination of the Achilles tendon in addition to standard anthropometric measures of stature and body weight. A 10-5 MHz linear array transducer was used to acquire longitudinal sonograms of the Achilles tendon, 20 mm proximal to the tendon insertion. Participants then completed a series (90-100 repetitions) of conditioning exercises against an effective resistance between 100% and 150% body weight. Longitudinal sonograms were repeated immediately on completion of the exercise intervention, and anteroposterior Achilles tendon thickness was determined. Achilles tendon thickness was significantly reduced immediately following conditioning exercise (t = 9.71, P < 0.001), resulting in an average transverse strain of -18.8%. In contrast to preexercise measures, Achilles tendon thickness was significantly correlated with body weight (r = 0.72, P < 0.001) and to a lesser extent height (r = 0.45, P = 0.01) and body mass index (r = 0.63, P < 0.001) after exercise. Conditioning of the Achilles tendon via resistive ankle exercises induces alterations in tendon structure that substantially improve correlations between Achilles tendon thickness and body anthropometry. It is recommended that conditioning exercises, which standardize the load history of tendon, are employed before measurements of sonographic tendon thickness in vivo.

  20. Changes in recruitment of Rhesus soleus and gastrocnemius muscles following a 14 day spaceflight

    NASA Technical Reports Server (NTRS)

    Hodgson, J. A.; Bodine-Fowler, S. C.; Roy, R. R.; De Leon, R. D.; De Guzman, C. P.; Koslovskaia, I.; Sirota, M.; Edgerton, V. R.

    1991-01-01

    The effect of microgravity on the recruitment patterns of the soleus, gastrocnemius, and tibialis-anterior muscles was investigated by comparing electromyograms (EMGs) of these muscles of Rhesus monkeys implanted with EMG electrodes, taken before and after a 14-day flight on board Cosmos 2044. It was found that the EMG amplitude values in the soleus muscle decreased after the spaceflight but returned to normal values over the 2-wk recovery period. The medial amplitudes of gastrocnemius and tibialis anterior were not changed by flight. Joint probability density distributions displayed changes after flight in both the soleus and gastrocnemius muscles, but not in tibialis anterior.

  1. Comparison of clinical outcomes and second-look arthroscopic findings after ACL reconstruction using a hamstring autograft or a tibialis allograft.

    PubMed

    Yoo, Seung-Hyun; Song, Eun-Kyoo; Shin, Young-Rok; Kim, Sung-Kyu; Seon, Jong-Keun

    2017-04-01

    The purpose of this prospective randomized clinical study was to compare the clinical and radiological outcomes, including tibial tunnel widening and the progression of osteoarthritis after ACL reconstruction using a hamstring autograft or a tibialis allograft. In addition, we compared the graft tear and synovial coverage of grafts in patients that underwent the second-look arthroscopy. Among 184 patients with an ACL injury who underwent ACL reconstruction, 68 patients of autograft group and 64 patients of tibialis allograft group were included for this study after minimum of 2-year follow-up. The Lachman and pivot-shift tests, Tegner activity score, Lysholm knee score, and IKDC score were compared between the two groups. The quadriceps and hamstring isokinetic strengths using dynamometer were also compared. Degree of OA was determined using the Kellgren-Lawrence grading system on the weight-bearing radiographs. In total, 51 patients (26 patients in autograft group and 25 in the tibialis allograft group) underwent the second-look arthroscopy, in which we compared the apparent tear of graft and synovial coverage of grafts. At the final follow-up, there were no statistical significances in the two groups in Lachman and pivot-shift tests (n.s.). The Tegner activity, Lysholm knee score, and IKDC scores were similar in the two groups. Moreover, no significant differences were observed in the muscle power (n.s.). Some patients showed the progression of OA (five in autograft and four in allograft groups) without intergroup difference (n.s.). Regarding the findings of second-look arthroscopy, although there was no significant difference in graft tear, synovial coverage was better in autograft group than in allograft group. Even though hamstring autografts and tibialis allografts provided good functional outcomes without significant differences, the second-look arthroscopy revealed that hamstring autografts produced better synovial coverage than tibialis allograft. I.

  2. Time-Dependent Alterations of MMPs, TIMPs and Tendon Structure in Human Achilles Tendons after Acute Rupture

    PubMed Central

    Minkwitz, Susann; Schmock, Aysha; Kurtoglu, Alper; Tsitsilonis, Serafeim; Manegold, Sebastian; Klatte-Schulz, Franka

    2017-01-01

    A balance between matrix metalloproteinases (MMPs) and their inhibitors (TIMPs) is required to maintain tendon homeostasis. Variation in this balance over time might impact on the success of tendon healing. This study aimed to analyze structural changes and the expression profile of MMPs and TIMPs in human Achilles tendons at different time-points after rupture. Biopsies from 37 patients with acute Achilles tendon rupture were taken at surgery and grouped according to time after rupture: early (2–4 days), middle (5–6 days), and late (≥7 days), and intact Achilles tendons served as control. The histological score increased from the early to the late time-point after rupture, indicating the progression towards a more degenerative status. In comparison to intact tendons, qRT-PCR analysis revealed a significantly increased expression of MMP-1, -2, -13, TIMP-1, COL1A1, and COL3A1 in ruptured tendons, whereas TIMP-3 decreased. Comparing the changes over time post rupture, the expression of MMP-9, -13, and COL1A1 significantly increased, whereas MMP-3 and -10 expression decreased. TIMP expression was not significantly altered over time. MMP staining by immunohistochemistry was positive in the ruptured tendons exemplarily analyzed from early and late time-points. The study demonstrates a pivotal contribution of all investigated MMPs and TIMP-1, but a minor role of TIMP-2, -3, and -4, in the early human tendon healing process. PMID:29053586

  3. Angiogenesis in healing autogenous flexor-tendon grafts.

    PubMed

    Gelberman, R H; Chu, C R; Williams, C S; Seiler, J G; Amiel, D

    1992-09-01

    On the basis of recent evidence that flexor tendon grafts may heal without the ingrowth of vascular adhesions, eighteen autogenous donor tendons of intrasynovial and extrasynovial origin were transferred to the synovial sheaths in the forepaws of nine dogs, and controlled passive mobilization was instituted early in the postoperative period. The angiogenic responses of the tendon grafts were determined with perfusion studies with India ink followed by cleaing of the tissues with the Spalteholz technique at two, four, and six weeks. A consistent pattern of neovascularization was noted in the donor tendons of extrasynovial origin. Vascular adhesions arising from the flexor digitorum superficialis and the tendon sheath enveloped the tendon grafts by two weeks. By six weeks, the vascularity of the tendon grafts of extrasynovial origin appeared completely integrated with that of the surrounding tissues. Examination of cross sections revealed that the segments of tendon had been completely vascularized by obliquely oriented intratendinous vessels. In contrast, the flexor tendon grafts of intrasynovial origin healed without ingrowth of vascular adhesions. Primary intrinsic neovascularization took place from the proximal and, to a lesser extent, distal sites of the sutures. Examination of cross sections revealed vessels extending through the surface layer of the tendon graft, with small vessels penetrating the interior of the tendons at regular intervals.

  4. Human tendon behaviour and adaptation, in vivo

    PubMed Central

    Magnusson, S Peter; Narici, Marco V; Maganaris, Constantinos N; Kjaer, Michael

    2008-01-01

    Tendon properties contribute to the complex interaction of the central nervous system, muscle–tendon unit and bony structures to produce joint movement. Until recently limited information on human tendon behaviour in vivo was available; however, novel methodological advancements have enabled new insights to be gained in this area. The present review summarizes the progress made with respect to human tendon and aponeurosis function in vivo, and how tendons adapt to ageing, loading and unloading conditions. During low tensile loading or with passive lengthening not only the muscle is elongated, but also the tendon undergoes significant length changes, which may have implications for reflex responses. During active loading, the length change of the tendon far exceeds that of the aponeurosis, indicating that the aponeurosis may more effectively transfer force onto the tendon, which lengthens and stores elastic energy subsequently released during unloading, in a spring-like manner. In fact, data recently obtained in vivo confirm that, during walking, the human Achilles tendon provides elastic strain energy that can decrease the energy cost of locomotion. Also, new experimental evidence shows that, contrary to earlier beliefs, the metabolic activity in human tendon is remarkably high and this affords the tendon the ability to adapt to changing demands. With ageing and disuse there is a reduction in tendon stiffness, which can be mitigated with resistance exercises. Such adaptations seem advantageous for maintaining movement rapidity, reducing tendon stress and risk of injury, and possibly, for enabling muscles to operate closer to the optimum region of the length–tension relationship. PMID:17855761

  5. Anterior cruciate ligament reconstruction: principles of treatment.

    PubMed

    Paschos, Nikolaos K; Howell, Stephen M

    2016-11-01

    Anterior cruciate ligament (ACL) reconstruction is one of the most common procedures in sports medicine. Several areas of controversy exist in ACL tear management which have engaged surgeons and researchers in debates towards identifying an ideal approach for these patients.This instructional review discusses the principles of ACL reconstruction in an attempt to provide guidelines and initiate a critical thinking approach on the most common areas of controversy regarding ACL reconstruction.Using high-level evidence from the literature, as presented in randomised controlled trials, systematic reviews, and meta-analyses, operative versus conservative treatment, timing of surgery, and rehabilitation are discussed. Also, the advantages and disadvantages of the most common types of autografts, such as patellar tendon and hamstrings as well as allografts are presented.Key considerations for the anatomical, histological, biomechanical and clinical data ('IDEAL') graft positioning are reviewed. Cite this article: Paschos NK, Howell SM. Anterior cruciate ligament reconstruction: principles of treatment. EFORT Open Rev 2016;398-408. DOI: 10.1302/2058-5241.1.160032.

  6. Deficits in heel-rise height and achilles tendon elongation occur in patients recovering from an Achilles tendon rupture.

    PubMed

    Silbernagel, Karin Grävare; Steele, Robert; Manal, Kurt

    2012-07-01

    Whether an Achilles tendon rupture is treated surgically or not, complications such as muscle weakness, decrease in heel-rise height, and gait abnormalities persist after injury. The purpose of this study was to evaluate if side-to-side differences in maximal heel-rise height can be explained by differences in Achilles tendon length. Case series; level of evidence, 4. Eight patients (mean [SD] age of 46 [13] years) with acute Achilles tendon rupture and 10 healthy subjects (mean [SD] age of 28 [8] years) were included in the study. Heel-rise height, Achilles tendon length, and patient-reported outcome were measured 3, 6, and 12 months after injury. Achilles tendon length was evaluated using motion analysis and ultrasound imaging. The Achilles tendon length test-retest reliability (intraclass correlation coefficient = 0.97) was excellent. For the healthy subjects, there were no side-to-side differences in tendon length and heel-rise height. Patients with Achilles tendon ruptures had significant differences between the injured and uninjured side for both tendon length (mean [SD] difference, 2.6-3.1 [1.2-1.4] cm, P = .017-.028) and heel-rise height (mean [SD] difference, -4.1 to -6.1 [1.7-1.8] cm, P = .012-.028). There were significant negative correlations (r = -0.943, P = .002, and r = -0.738, P = .037) between the side-to-side difference in heel-rise height and Achilles tendon length at the 6- and 12-month evaluations, respectively. The side-to-side difference found in maximal heel-rise height can be explained by a difference in Achilles tendon length in patients recovering from an Achilles tendon rupture. Minimizing tendon elongation appears to be an important treatment goal when aiming for full return of function.

  7. Tendon sheath fibroma in the thigh.

    PubMed

    Moretti, Vincent M; Ashana, Adedayo O; de la Cruz, Michael; Lackman, Richard D

    2012-04-01

    Tendon sheath fibromas are rare, benign soft tissue tumors that are predominantly found in the fingers, hands, and wrists of young adult men. This article describes a tendon sheath fibroma that developed in the thigh of a 70-year-old man, the only known tendon sheath fibroma to form in this location. Similar to tendon sheath fibromas that develop elsewhere, our patient's lesion presented as a painless, slow-growing soft tissue nodule. Physical examination revealed a firm, nontender mass with no other associated signs or symptoms. Although the imaging appearance of tendon sheath fibromas varies, our patient's lesion appeared dark on T1- and bright on T2-weighted magnetic resonance imaging. It was well marginated and enhanced with contrast.Histologically, tendon sheath fibromas are composed of dense fibrocollagenous stromas with scattered spindle-shaped fibroblasts and narrow slit-like vascular spaces. Most tendon sheath fibromas can be successfully removed by marginal excision, although 24% of lesions recur. No lesions have metastasized. Our patient's tendon sheath fibroma was removed by marginal excision, and the patient remained disease free 35 months postoperatively. Despite its rarity, tendon sheath fibroma should be included in the differential diagnosis of a thigh mass on physical examination or imaging, especially if it is painless, nontender, benign appearing, and present in men. Copyright 2012, SLACK Incorporated.

  8. The promoting effect of pentadecapeptide BPC 157 on tendon healing involves tendon outgrowth, cell survival, and cell migration.

    PubMed

    Chang, Chung-Hsun; Tsai, Wen-Chung; Lin, Miao-Sui; Hsu, Ya-Hui; Pang, Jong-Hwei Su

    2011-03-01

    Pentadecapeptide BPC 157, composed of 15 amino acids, is a partial sequence of body protection compound (BPC) that is discovered in and isolated from human gastric juice. Experimentally it has been demonstrated to accelerate the healing of many different wounds, including transected rat Achilles tendon. This study was designed to investigate the potential mechanism of BPC 157 to enhance healing of injured tendon. The outgrowth of tendon fibroblasts from tendon explants cultured with or without BPC 157 was examined. Results showed that BPC 157 significantly accelerated the outgrowth of tendon explants. Cell proliferation of cultured tendon fibroblasts derived from rat Achilles tendon was not directly affected by BPC 157 as evaluated by MTT assay. However, the survival of BPC 157-treated cells was significantly increased under the H(2)O(2) stress. BPC 157 markedly increased the in vitro migration of tendon fibroblasts in a dose-dependent manner as revealed by transwell filter migration assay. BPC 157 also dose dependently accelerated the spreading of tendon fibroblasts on culture dishes. The F-actin formation as detected by FITC-phalloidin staining was induced in BPC 157-treated fibroblasts. The protein expression and activation of FAK and paxillin were determined by Western blot analysis, and the phosphorylation levels of both FAK and paxillin were dose dependently increased by BPC 157 while the total amounts of protein was unaltered. In conclusion, BPC 157 promotes the ex vivo outgrowth of tendon fibroblasts from tendon explants, cell survival under stress, and the in vitro migration of tendon fibroblasts, which is likely mediated by the activation of the FAK-paxillin pathway.

  9. Greater inadvertent muscle damage in direct anterior approach when compared with the direct superior approach for total hip arthroplasty.

    PubMed

    Amanatullah, D F; Masini, M A; Roger, D J; Pagnano, M W

    2016-08-01

    We wished to quantify the extent of soft-tissue damage sustained during minimally invasive total hip arthroplasty through the direct anterior (DA) and direct superior (DS) approaches. In eight cadavers, the DA approach was performed on one side, and the DS approach on the other, a single brand of uncemented hip prosthesis was implanted by two surgeons, considered expert in their surgical approaches. Subsequent reflection of the gluteus maximus allowed the extent of muscle and tendon damage to be measured and the percentage damage to each anatomical structure to be calculated. The DA approach caused substantially greater damage to the gluteus minimus muscle and tendon when compared with the DS approach (t-test, p = 0.049 and 0.003, respectively). The tensor fascia lata and rectus femoris muscles were damaged only in the DA approach. There was no difference in the amount of damage to the gluteus medius muscle and tendon, piriformis tendon, obturator internus tendon, obturator externus tendon or quadratus femoris muscle between approaches. The posterior soft-tissue releases of the DA approach damaged the gluteus minimus muscle and tendon, piriformis tendon and obturator internus tendon. The DS approach caused less soft-tissue damage than the DA approach. However the clinical relevance is unknown. Further clinical outcome studies, radiographic evaluation of component position, gait analyses and serum biomarker levels are necessary to evaluate and corroborate the safety and efficacy of the DS approach. Cite this article: Bone Joint J 2016;98-B1036-42. ©2016 The British Editorial Society of Bone & Joint Surgery.

  10. Abnormal origins of the long head of the biceps tendon can lead to rotator cuff pathology: a report of two cases.

    PubMed

    Zhang, Alan L; Gates, Cameron H; Link, Thomas M; Ma, C Benjamin

    2014-11-01

    Previous case reports have highlighted various anomalous origins of the long head of the biceps tendon (LHBT) that do not originate from the superior glenoid labrum or supraglenoid tubercle. Yet, these cases were all reported as incidental findings and were not thought to cause any significant shoulder pathology. We present the magnetic resonance (MR) imaging and clinical treatment of two cases where aberrant intra-articular origins of the long head of the biceps tendon from the anterior edge of the supraspinatus tendon may have contributed to symptomatic rotator cuff pathology. Arthroscopy confirmed MR findings of partial articular-sided supraspinatus lesions in close proximity to the anomalous origins and treatment with tenodesis of the LHBT successfully relieved symptoms. Although rare occurrences with subtle and potentially misleading imaging findings, it is important to be aware of aberrant origins of the LHBT that may contribute to concomitant rotator cuff pathology.

  11. Bone-Patellar Tendon-Bone Versus Soft-Tissue Allograft for Anterior Cruciate Ligament Reconstruction: A Systematic Review.

    PubMed

    Joyce, Christopher D; Randall, Kyle L; Mariscalco, Michael W; Magnussen, Robert A; Flanigan, David C

    2016-02-01

    To describe the outcomes of bone-patellar tendon-bone (BPTB) and soft-tissue allografts in anterior cruciate ligament (ACL) reconstruction with respect to graft failure risk, physical examination findings, instrumented laxity, and patient-reported outcomes. A search of the PubMed, Scopus, CINAHL (Cumulative Index to Nursing and Allied Health Literature) Complete, Cochrane Collaboration, and SPORTDiscus databases was performed. English-language studies with outcome data on primary ACL reconstruction with nonirradiated BPTB and soft-tissue allografts were identified. Outcome data included failure risk, physical examination findings, instrumented laxity measurements, and patient-reported outcome scores. Seventeen studies met the inclusion criteria. Of these studies, 11 reported on BPTB allografts exclusively, 5 reported on soft-tissue allografts exclusively, and 1 compared both types. The comparative study showed no difference in failure risk, Lachman grade, pivot-shift grade, instrumented laxity, or overall International Knee Documentation Committee score between the 2 allograft types. Data from all studies yielded a failure risk of 10.3% (95% confidence interval [CI], 4.5% to 18.1%) in the soft-tissue group and 15.2% (95% CI, 11.3% to 19.6%) in the BPTB group. The risk of a Lachman grade greater than 5 mm was 6.4% (95% CI, 1.7% to 13.7%) in the soft-tissue group and 8.6% (95% CI, 6.3% to 11.2%) in the BPTB group. The risk of a grade 2 or 3 pivot shift was 1.4% (95% CI, 0.3% to 3.3%) in the soft-tissue group and 4.1% (95% CI, 1.9% to 7.2%) in the BPTB group. One comparative study showed no difference in results after ACL reconstruction with nonirradiated BPTB and soft-tissue allografts. Inclusion of case series in the analysis showed qualitatively similar outcomes with the 2 graft types. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Role of tissue-engineered artificial tendon in healing of a large Achilles tendon defect model in rabbits.

    PubMed

    Moshiri, Ali; Oryan, Ahmad; Meimandi-Parizi, Abdolhamid

    2013-09-01

    Treatment of large Achilles tendon defects is technically demanding. Tissue engineering is an option. We constructed a collagen-based artificial tendon, covered it with a polydioxanon (PDS) sheath, and studied the role of this bioimplant on experimental tendon healing in vivo. A 2-cm tendon gap was created in the left Achilles tendon of rabbits (n = 120). The animals were randomly divided into 3 groups: control (no implant), treated with tridimensional-collagen, and treated with tridimensional-collagen-bidimensional-PDS implants. Each group was divided into 2 subgroups of 60 and 120 days postinjury (DPI). Another 50 pilot animals were used to study the host-implant interaction. Physical activity of the animals was scored and ultrasonographic and bioelectrical characteristics of the injured tendons were investigated weekly. After euthanasia, macro, micro, and nano morphologies and biophysical and biomechanical characteristics of the healing tendons were studied. Treatment improved function of the animals, time dependently. At 60 and 120 DPI, the treated tendons showed significantly higher maximum load, yield, stiffness, stress, and modulus of elasticity compared with controls. The collagen implant induced inflammation and absorbed the migrating fibroblasts in the defect area. By its unique architecture, it aligned the fibroblasts and guided their proliferation and collagen deposition along the stress line of the tendon and resulted in improved collagen density, micro-amp, micro-ohm, water uptake, and delivery of the regenerated tissue. The PDS-sheath covering amplified these characteristics. The implants were gradually absorbed and replaced by a new tendon. Minimum amounts of peritendinous adhesion, muscle atrophy, and fibrosis were observed in the treated groups. Some remnants of the implants were preserved and accepted as a part of the new tendon. The implants were cytocompatible, biocompatible, biodegradable, and effective in tendon healing and regeneration. This

  13. Aging Does Not Alter Tendon Mechanical Properties During Homeostasis, but does Impair Flexor Tendon Healing

    PubMed Central

    Ackerman, Jessica E.; Bah, Ibrahima; Jonason, Jennifer H.; Buckley, Mark R.; Loiselle, Alayna E.

    2017-01-01

    Aging is an important factor in disrupted homeostasis of many tissues. While an increased incidence of tendinopathy and tendon rupture are observed with aging, it is unclear whether this is due to progressive changes in tendon cell function and mechanics over time, or an impaired repair reaction from aged tendons in response to insult or injury. In the present study we examined changes in the mechanical properties of Flexor Digitorum Longus (FDL), Flexor Carpi Ulnaris (FCU), and tail fascicles in both male and female C57Bl/6 mice between 3-27 months of age to better understand the effects of sex and age on tendon homeostasis. No change in max load at failure was observed in any group over the course of aging, although there were significant decreases in toe and linear stiffness in female mice from 3-months to 15, and to 22-27-months. No changes in cell proliferation were observed with aging, although an observable decrease in cellularity occurred in 31-month old tendons. Given that aging did not dramatically alter tendon mechanical homeostasis we hypothesized that a disruption in tendon homeostasis, via acute injury would result in an impaired healing response. Significant decreases in max load, stiffness, and yield load were observed in repairs of 22-month old mice, relative to 4-month old mice. No changes in cell proliferation were observed between young and aged, however a dramatic loss of bridging collagen extracellular matrix was observed in aged repairs suggest that matrix production, but not cell proliferation leads to impaired tendon healing with aging. PMID:28419543

  14. Cytoplasm-to-myonucleus ratios following microgravity.

    PubMed

    Kasper, C E; Xun, L

    1996-10-01

    The cytoplasmic volume-to-myonucleus ratio in the tibialis anterior and gastrocnemius muscles of juvenile rats after 5.4 days of microgravity was studied. Three groups of rats (n = 8 each) were used. The experimental group (space rats) was flown aboard the space shuttle Discovery (NASA, STS-48), while two ground-based groups, one hindlimb suspended (suspended rats), one non-suspended (control), served as controls. Single fibre analysis revealed a significant decrease in cross-sectional area (microns2) in the gastrocnemius for both the space and the suspended rats; in the tibialis anterior only the suspended rats showed a significant decrease. Myonuclei counts (myonuclei per mm) in both the tibialis anterior and gastrocnemius were significantly increased in the space rats but not in the suspended rats. The mean myonuclear volume (individual nuclei: microns3) in tibialis anterior fibres from the space rats, and in gastrocnemius fibres from both the space and the suspended rats, was significantly lower than that in the respective control group. Estimation of the total myonuclear volume (microns3 per.mm), however, revealed no significant differences between the three groups in either the tibialis anterior or gastrocnemius. The described changes in the cross-sectional area and myonuclei numbers resulted in significant decreases in the cytoplasmic volume-to-myonucleus ratio (microns3 x 10(3)) in both muscles and for both space and suspended rats (tibialis anterior; 15.6 +/- 0.6 (space), 17.2 +/- 1.0 (suspended), 20.8 +/- 0.9 (control): gastrocnemius; 13.4 +/- 0.4 (space) and 14.9 +/- 1.1 (suspended) versus 18.1 +/- 1.1 (control)). These results indicate that even short periods of unweighting due to microgravity or limb suspension result in changes in skeletal muscle fibres which lead to significant decreases in the cytoplasmic volume-to-myonucleus ratio.

  15. Using pre-operative MRI to predict intraoperative hamstring graft size for anterior cruciate ligament reconstruction.

    PubMed

    Leiter, Jeff; Elkurbo, Mohamed; McRae, Sheila; Chiu, James; Froese, Warren; MacDonald, Peter

    2017-01-01

    Large variation in tendon size between individuals makes hamstring graft diameter for anterior cruciate ligament (ACL) reconstruction unpredictable. Inadequate graft diameter may necessitate an alternative source of tissue requiring pre-operative planning. The purpose of this study was to determine whether magnetic resonance image (MRI) measurements and clinical anthropometric data are predictive of hamstring tendon graft diameter. Data from 109 patients having ACL reconstruction with semitendinosus-gracilis (STGT) autograft were retrospectively evaluated. Cross-sectional area (CSA) of the gracilis tendon (GT) and semitendinosus tendon (ST) were determined from pre-operative MRI scans. Variables included pre-operative height, weight, body mass index (BMI), age and gender; and intra-operative graft diameter. Correlations between anthropometric variables, hamstring tendons CSA and intra-operative graft diameter were calculated. Multiple stepwise regression was performed to assess the predictive value of these variables to graft diameter. Sensitivity and specificity were calculated to evaluate the utility of MRI CSA measurements in accurately identifying inadequate graft diameter (<8 mm). All anthropometric variables were positively correlated with intraoperative graft diameter (p < 0.01). Semitendinosus-gracilis tendon CSA (p < 0.001) and STGT CSA and weight (p < 0.001) were significantly predictive models of graft diameter. Sensitivity and specificity were 79 and 74 %, respectively. The strongest indicators of a four-stranded STGT graft for primary ACL reconstruction were STGT CSA on MRI plus weight. Measurement of graft diameter can be performed pre-operatively via MRI to identify tendons that may be of inadequate size for ACL reconstruction. This can assist with surgical planning to determine the most appropriate graft choice. III.

  16. Long latency postural responses are functionally modified by cognitive set.

    PubMed

    Beckley, D J; Bloem, B R; Remler, M P; Roos, R A; Van Dijk, J G

    1991-10-01

    We examined how cognitive set influences the long latency components of normal postural responses in the legs. We disturbed the postural stability of standing human subjects with sudden toe-up ankle rotations. To influence the subjects' cognitive set, we varied the rotation amplitude either predictably (serial 4 degrees versus serial 10 degrees) or unpredictably (random mixture of 4 degrees and 10 degrees). The subjects' responses to these ankle rotations were assessed from the EMG activity of the tibialis anterior, the medial gastrocnemius, and the vastus lateralis muscles of the left leg. The results indicate that, when the rotation amplitude is predictable, only the amplitude of the long latency (LL) response in tibialis anterior and vastus lateralis varied directly with perturbation size. Furthermore, when the rotation amplitude is unpredictable, the central nervous system selects a default amplitude for the LL response in the tibialis anterior. When normal subjects are exposed to 2 perturbation amplitudes which include the potential risk of falling, the default LL response in tibialis anterior appropriately anticipates the larger amplitude perturbation rather than the smaller or an intermediate one.

  17. [The mini-open Latarjet procedure for treatment of recurrent anterior instability of the shoulder].

    PubMed

    Pogorzelski, J; Beitzel, K; Imhoff, A B; Braun, S

    2016-12-01

    Shoulder stabilization. Symptomatic recurrent anterior shoulder instability combined with glenoid bone loss of approximately 20-35 % of the glenoid surface, engaging Hill-Sachs lesion and/or previously failed arthroscopic Bankart repair. In patients with a high risk of redislocation (contact sports) or irreparable soft tissue injury the Latarjet procedure can be considered as a first-line treatment. Contraindicated if arthroscopic Bankart repair is possible. Irreparable damage of subscapularis tendon. Bony defect >35 % of the glenoid that cannot be filled with coracoid bone block. Arbitrary shoulder dislocation. Young patients with open growth plates (relative contraindication). Mini-open deltopectoral approach of approximately 6 cm. Preparation of the coracoid process and the conjoined tendons. Osteotomy of the coracoid process at its base using a 90° sawblade. Split of the subscapularis tendon. Preparation of the glenoid defect and implantation of 2-3 suture anchors where appropriate. Drilling of two parallel holes through the coracoid process. Fixation of the bone block with cannulated screws at the anterior glenoid rim and refixation of the joint capsula, if necessary with the help of the suture anchors. Wound drainage and closure in layers. Intermittent immobilization in a sling for 6 weeks with limited abduction, flexion and external rotation. Sport-specific training after 3 months, over-head sports after 6 months. Since 2009 64 mini-open Latarjet procedures (61 patients) performed. In all, 9.4 % of patients suffered from persistent instability (dislocations and subluxations); only 1 patient needed revision surgery due to instability.

  18. Role of biomechanics in the understanding of normal, injured, and healing ligaments and tendons

    PubMed Central

    Jung, Ho-Joong; Fisher, Matthew B; Woo, Savio L-Y

    2009-01-01

    Ligaments and tendons are soft connective tissues which serve essential roles for biomechanical function of the musculoskeletal system by stabilizing and guiding the motion of diarthrodial joints. Nevertheless, these tissues are frequently injured due to repetition and overuse as well as quick cutting motions that involve acceleration and deceleration. These injuries often upset this balance between mobility and stability of the joint which causes damage to other soft tissues manifested as pain and other morbidity, such as osteoarthritis. The healing of ligament and tendon injuries varies from tissue to tissue. Tendinopathies are ubiquitous and can take up to 12 months for the pain to subside before one could return to normal activity. A ruptured medial collateral ligament (MCL) can generally heal spontaneously; however, its remodeling process takes years and its biomechanical properties remain inferior when compared to the normal MCL. It is also known that a midsubstance anterior cruciate ligament (ACL) tear has limited healing capability, and reconstruction by soft tissue grafts has been regularly performed to regain knee function. However, long term follow-up studies have revealed that 20–25% of patients experience unsatisfactory results. Thus, a better understanding of the function of ligaments and tendons, together with knowledge on their healing potential, may help investigators to develop novel strategies to accelerate and improve the healing process of ligaments and tendons. With thousands of new papers published in the last ten years that involve biomechanics of ligaments and tendons, there is an increasing appreciation of this subject area. Such attention has positively impacted clinical practice. On the other hand, biomechanical data are complex in nature, and there is a danger of misinterpreting them. Thus, in these review, we will provide the readers with a brief overview of ligaments and tendons and refer them to appropriate methodologies used to

  19. Effects of initial graft tension on femoral tunnel widening after anatomic anterior cruciate ligament reconstruction using a bone-patellar tendon-bone graft.

    PubMed

    Taketomi, Shuji; Inui, Hiroshi; Tahara, Keitaro; Shirakawa, Nobuyuki; Tanaka, Sakae; Nakagawa, Takumi

    2017-09-01

    The effects of initial graft tension upon tunnel widening (TW) following anatomic anterior cruciate ligament (ACL) reconstruction have not been elucidated. The purpose of this study was to retrospectively investigate the effect of two different graft-tensioning protocols upon femoral TW following anatomic ACL reconstruction using a bone-patellar tendon-bone (BPTB) graft and a three-dimensional (3D) computed tomography (CT) model. Forty-three patients who underwent isolated ACL reconstruction using BPTB grafts were included in this study. In 18 out of the 43 patients, the graft was fixed at full knee extension with manual maximum pull (Group H). These patients were compared with 25 patients in whom the BPTB graft was fixed at full knee extension with 80-N pull (Group L). Tunnel aperture area was measured using 3D CT 1 week and 1 year postoperatively, thus enabling us to calculate the percentage change in the area of femoral tunnel aperture. Clinical assessment was performed 1 year postoperatively, corresponding to the time period of CT assessment, and involved the evaluation of Lysholm score, anterior knee stability using a KneeLax3 arthrometer, and the pivot-shift test. When measured at 1 year postoperatively, the mean area of the femoral tunnel aperture had increased by 78.6 ± 36.8% in Group H when compared with at 1 week postoperatively, whereas that of Group L had increased by 27.7 ± 32.3%. Furthermore, TW (%) in Group H was significantly greater than that of Group L (P < 0.001). No significant differences were detected between the two groups with regard to any of the clinical outcomes evaluated. High levels of initial graft tension resulted in greater TW of the femoral tunnel aperture following anatomical ACL reconstruction using BPTB grafts. However, such levels of graft tension did not affect clinical outcome.

  20. Structure-mechanics relationships in mineralized tendons.

    PubMed

    Spiesz, Ewa M; Zysset, Philippe K

    2015-12-01

    In this paper, we review the hierarchical structure and the resulting elastic properties of mineralized tendons as obtained by various multiscale experimental and computational methods spanning from nano- to macroscale. The mechanical properties of mineralized collagen fibres are important to understand the mechanics of hard tissues constituted by complex arrangements of these fibres, like in human lamellar bone. The uniaxial mineralized collagen fibre array naturally occurring in avian tendons is a well studied model tissue for investigating various stages of tissue mineralization and the corresponding elastic properties. Some avian tendons mineralize with maturation, which results in a graded structure containing two zones of distinct morphology, circumferential and interstitial. These zones exhibit different amounts of mineral, collagen, pores and a different mineral distribution between collagen fibrillar and extrafibrillar space that lead to distinct elastic properties. Mineralized tendon cells have two phenotypes: elongated tenocytes placed between fibres in the circumferential zone and cuboidal cells with lower aspect ratios in the interstitial zone. Interestingly some regions of avian tendons seem to be predestined to mineralization, which is exhibited as specific collagen cross-linking patterns as well as distribution of minor tendon constituents (like proteoglycans) and loss of collagen crimp. Results of investigations in naturally mineralizing avian tendons may be useful in understanding the pathological mineralization occurring in some human tendons. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Ultrasonographic assessment of the equine palmar tendons

    PubMed Central

    Padaliya, N. R.; Ranpariya, J. J.; Kumar, Dharmendra; Javia, C. B.; Barvalia, D. R.

    2015-01-01

    Aim: The present study was conducted to evaluate the equine palmar tendon by ultrasonography (USG) in standing the position. Materials and Methods: USG of palmar tendons was performed in 40 adult horses using linear transducer having frequency of 10-18 MHz (e-soate, My Lab FIVE) and L52 linear array transducer (Titan, SonoSite) with frequencies ranging from 8 to 10 MHz. Palmar tendon was divided into 7 levels from distal to accessory carpal bone up to ergot in transverse scanning and 3 levels in longitudinal scanning. Results: The USG evaluation was very useful for diagnosis of affections of the conditions such as chronic bowed tendon, suspensory ligament desmitis, carpal sheath tenosynovitis and digital sheath effusions. The mean cross-sectional area (cm2) of affected tendons was significantly increased in affected than normal tendons. The echogenicity was also found reduced in affected tendons and ligaments along with disorganization of fiber alignment depending on the severity of lesion and injury. Conclusion: USG proved ideal diagnostic tool for diagnosis and post-treatment healing assessment of tendon injuries in horses. PMID:27047074

  2. Surgical Treatment for Failure of Repair of Patellar and Quadriceps Tendon Rupture With Ipsilateral Hamstring Tendon Graft.

    PubMed

    Maffulli, Nicola; Papalia, Rocco; Torre, Guglielmo; Denaro, Vincenzo

    2017-03-01

    Tears of the patellar and quadriceps tendon are common in the active population, especially in athletes. At present, several techniques for surgical repair and reconstruction are available. When reruptures occur, a reconstruction is mandatory. In the present paper, we describe a surgical technique for patellar and quadriceps tendon reconstruction using ipsilateral hamstring autograft. After routine hamstring tendon harvesting, the tendon ends are prepared using a whip stitch. A transverse tunnel is drilled in the midportion of the patella, the hamstring graft is passed through the patella, and firmly secured to the patellar tunnel openings with sutures. The details of the technique are fully described. Autologous ipsilateral hamstring tendon grafts provide a secure sound means to manage these challenging injuries.

  3. Markers for the identification of tendon-derived stem cells in vitro and tendon stem cells in situ - update and future development.

    PubMed

    Lui, Pauline Po Yee

    2015-06-02

    The efficacy of tendon-derived stem cells (TDSCs) for the promotion of tendon and tendon-bone junction repair has been reported in animal studies. Modulation of the tendon stem cell niche in vivo has also been reported to influence tendon structure. There is a need to have specific and reliable markers that can define TDSCs in vitro and tendon stem cells in situ for several reasons: to understand the basic biology of TDSCs and their subpopulations in vitro; to understand the identity, niches and functions of tendon/progenitor stem cells in vivo; to meet the governmental regulatory requirements for quality of TDSCs when translating the exciting preclinical findings into clinical trial/practice; and to develop new treatment strategies for mobilizing endogenous stem/progenitor cells in tendon. TDSCs were reported to express the common mesenchymal stem cell (MSC) markers and some embryonic stem cell (ESC) markers, and there were attempts to use these markers to label tendon stem cells in situ. Are these stem cell markers useful for the identification of TDSCs in vitro and tracking of tendon stem cells in situ? This review aims to discuss the values of the panel of MSC, ESC and tendon-related markers for the identification of TDSCs in vitro. Important factors influencing marker expression by TDSCs are discussed. The usefulness and limitations of the panel of MSC, ESC and tendon-related markers for tracking stem cells in tendon, especially tendon stem cells, in situ are then reviewed. Future research directions are proposed.

  4. Collagen structure of tendon relates to function.

    PubMed

    Franchi, Marco; Trirè, Alessandra; Quaranta, Marilisa; Orsini, Ester; Ottani, Victoria

    2007-03-30

    A tendon is a tough band of fibrous connective tissue that connects muscle to bone, designed to transmit forces and withstand tension during muscle contraction. Tendon may be surrounded by different structures: 1) fibrous sheaths or retinaculae; 2) reflection pulleys; 3) synovial sheaths; 4) peritendon sheaths; 5) tendon bursae. Tendons contain a) few cells, mostly represented by tenoblasts along with endothelial cells and some chondrocytes; b) proteoglycans (PGs), mainly decorin and hyaluronan, and c) collagen, mostly type I. Tendon is a good example of a high ordered extracellular matrix in which collagen molecules assemble into filamentous collagen fibrils (formed by microfibrils) which aggregate to form collagen fibers, the main structural components. It represents a multihierarchical structure as it contains collagen molecules arranged in fibrils then grouped in fibril bundles, fascicles and fiber bundles that are almost parallel to the long axis of the tendon, named as primary, secondary and tertiary bundles. Collagen fibrils in tendons show prevalently large diameter, a D-period of about 67 nm and appear built of collagen molecules lying at a slight angle (< 5 degrees). Under polarized light microscopy the collagen fiber bundles appear crimped with alternative dark and light transverse bands. In recent studies tendon crimps observed via SEM and TEM show that the single collagen fibrils suddenly changing their direction contain knots. These knots of collagen fibrils inside each tendon crimp have been termed "fibrillar crimps", and even if they show different aspects they all may fulfil the same functional role. As integral component of musculoskeletal system, the tendon acts to transmit muscle forces to the skeletal system. There is no complete understanding of the mechanisms in transmitting/absorbing tensional forces within the tendon; however it seems likely that a flattening of tendon crimps may occur at a first stage of tendon stretching. Increasing

  5. Associations between abnormal ultrasound color Doppler measures and tendon pain symptoms in badminton players during a season: a prospective cohort study.

    PubMed

    Boesen, Anders Ploug; Boesen, Morten Ilum; Torp-Pedersen, Soren; Christensen, Robin; Boesen, Lars; Hölmich, Per; Nielsen, Michael Bachmann; Koenig, Merete Juhl; Hartkopp, Andreas; Ellegaard, Karen; Bliddal, Henning; Langberg, Henning

    2012-03-01

    Color Doppler ultrasound is widely used to examine intratendinous flow in individuals with overuse tendon problems, but the association between color Doppler and pain is still unclear. Intratendinous flow is present and associated with pain in badminton players, and intratendinous flow and pain increase during a badminton season. Cohort study (prognosis); Level of evidence, 2. Ninety-five semiprofessional badminton players were included in the study at a tournament at the start of the badminton season. All players were interviewed regarding pain. The anterior knee tendons and Achilles tendons were studied. Each tendon was scored using a quantitative grading system (grades 0-5) and a qualitative scoring system (color fraction) using color Doppler ultrasound. Eight months later, 86 of the players (91%) were retested by the same investigators during an equivalent badminton tournament (including 1032 tendon regions; 86 players with 4 tendons each with 3 regions), thus forming the study group. At the start of the season, 24 players (28%) experienced pain in 37 tendons (11%), and at the end of the season, 31 players (36%) experienced pain in 51 tendons (15%), which was a statistically significant increase (P = .0002). Abnormal flow was found in 230 tendon regions in 71 players (83%) at the start of the season compared with 78 tendon regions in 41 players (48%) at the follow-up. The decrease in abnormal flow was statistically significant (P < .0001). Of the 37 painful tendons at the start of the season, 25 had abnormal flow (68%). In contrast, 131 tendons (85%) with abnormal flow at the start of the season were pain free. At the end of the season, 18 of the 51 painful tendons (35%) had abnormal flow. Ninety-six of the 131 pain-free tendons (73%) with abnormal flow at the start of the season were normalized (no pain and normal flow) at the end of the season. It was not possible to verify any association between intratendinous flow and pain at the start of the season or at

  6. Distal biceps reconstruction using an Achilles tendon allograft, transosseous EndoButton, and Pulvertaft weave with tendon wrap technique for retracted, irreparable distal biceps ruptures.

    PubMed

    Phadnis, Joideep; Flannery, Olivia; Watts, Adam C

    2016-06-01

    Distal biceps ruptures can result in ongoing pain and weakness when treated nonoperatively. If retraction of the tendon renders primary repair impossible, reconstruction using a graft is recommended. The current literature includes a variety of techniques with studies reporting small patient numbers. The aim of this study was to report the results of a larger cohort of patients using a technique modified from those previously described in the literature. Twenty-one consecutive male patients underwent distal biceps reconstruction through 2 small anterior incisions using an Achilles tendon allograft that was fixed distally using a transosseous EndoButton and secured proximally using a Pulvertaft weave and tendon wrap. The mean age was 44 years, and the mean time to surgery was 25 months (range, 2-96 months). Functional outcomes were collected prospectively. The mean preoperative Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score (11 patients) was 1.9 (range, 0-4.5). The mean postoperative Oxford Elbow Score, QuickDASH score, and Mayo Elbow Performance Score were 44.7 (range, 35-48), 4 (range, 0-20.5), and 92.9 (range, 70-100), respectively, at a mean follow up of 15 months (range, 6-35 months). The mean postoperative QuickDASH score was significantly improved compared with preoperatively (P < .001). All patients were satisfied and all returned to their previous level of activity. There were 2 transient lateral antebrachial cutaneous nerve paresthesias, and 2 patients had a 5° extension lag. There were no other complications. Achilles allograft reconstruction of retracted irreparable distal biceps ruptures provides consistently good results with few complications using this technique. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  7. IFSSH Flexor Tendon Committee report 2014: from the IFSSH Flexor Tendon Committee (Chairman: Jin Bo Tang).

    PubMed

    Tang, Jin Bo; Chang, James; Elliot, David; Lalonde, Donald H; Sandow, Michael; Vögelin, Esther

    2014-01-01

    Hand surgeons continue to search for the best surgical flexor tendon repair and treatment of the tendon sheaths and pulleys, and they are attempting to establish postoperative regimens that fit diverse clinical needs. It is the purpose of this report to present the current views, methods, and suggestions of six senior hand surgeons from six different countries - all experienced in tendon repair and reconstruction. Although certainly there is common ground, the report presents provocative views and approaches. The report reflects an update in the views of the committee. We hope that it is helpful to surgeons and therapists in treating flexor tendon injuries.

  8. Grasp Assist Device with Shared Tendon Actuator Assembly

    NASA Technical Reports Server (NTRS)

    Ihrke, Chris A. (Inventor); Bergelin, Bryan J. (Inventor); Bridgwater, Lyndon (Inventor)

    2015-01-01

    A grasp assist device includes a glove with first and second tendon-driven fingers, a tendon, and a sleeve with a shared tendon actuator assembly. Tendon ends are connected to the respective first and second fingers. The actuator assembly includes a drive assembly having a drive axis and a tendon hook. The tendon hook, which defines an arcuate surface slot, is linearly translatable along the drive axis via the drive assembly, e.g., a servo motor thereof. The flexible tendon is routed through the surface slot such that the surface slot divides the flexible tendon into two portions each terminating in a respective one of the first and second ends. The drive assembly may include a ball screw and nut. An end cap of the actuator assembly may define two channels through which the respective tendon portions pass. The servo motor may be positioned off-axis with respect to the drive axis.

  9. Biomechanical and clinical factors related to stage I posterior tibial tendon dysfunction.

    PubMed

    Rabbito, Melissa; Pohl, Michael B; Humble, Neil; Ferber, Reed

    2011-10-01

    Case control. To investigate differences in arch height, ankle muscle strength, and biomechanical factors in individuals with stage I posterior tibial tendon dysfunction (PTTD) in comparison to healthy individuals. PTTD is a progressive condition, so early recognition and treatment are essential to help delay or reverse the progression. However, no previous studies have investigated stage I PTTD, and no single study has measured static anatomical structure, muscle strength, and gait mechanics in this population. Twelve individuals with stage I PTTD and 12 healthy, age- and gender-matched control subjects, who were engaged in running-related activities, participated in this study. Measurements of arch height index, maximum voluntary ankle invertor muscle strength, and 3-dimensional rearfoot and medial longitudinal arch kinematics during walking were obtained. The runners with PTTD demonstrated significantly lower seated arch height index (P = .02) and greater (P = .03) and prolonged (P = .05) peak rearfoot eversion angle during gait, compared to the healthy runners. No differences were found in standing arch height index values (P = .28), arch rigidity index (P = .06), ankle invertor strength (P = .49), or peak medial longitudinal arch values (P = .49) between groups. The increased foot pronation is hypothesized to place greater strain on the posterior tibialis muscle, which may partially explain the progressive nature of this condition.

  10. Evolution of the Achilles tendon: The athlete's Achilles heel?

    PubMed

    Malvankar, S; Khan, W S

    2011-12-01

    The Achilles tendon is believed to have first developed two million years ago enabling humans to run twice as fast. However if the Achilles tendon is so important in terms of evolution, then why is this tendon so prone to injury - especially for those more active like athletes. The Achilles tendon had an integral role in evolving apes from a herbivorous diet to early humans who started hunting for food over longer distances, resulting in bipedal locomotion. Evolutionary advantages of the Achilles tendon includes it being the strongest tendon in the body, having an energy-saving mechanism for fast locomotion, allows humans to jump and run, and additionally is a spring and shock absorber during gait. Considering these benefits it is therefore not surprising that studies have shown athletes have thicker Achilles tendons than subjects who are less active. However, contradictory to these findings that show the importance of the Achilles tendon for athletes, it is well known that obtaining an Achilles tendon injury for an athlete can be career-altering. A disadvantage of the Achilles tendon is that the aetiology of its pathology is complicated. Achilles tendon ruptures are believed to be caused by overloading the tensed tendon, like during sports. However studies have also shown athlete Achilles tendon ruptures to have degenerative changes in the tendon. Other flaws of the Achilles tendon are its non-uniform vascularity and incomplete repair system which may suggest the Achilles tendon is on the edge of evolution. Research has shown that there is a genetic influence on the predisposition a person has towards Achilles tendon injuries. So if this tendon is here to stay in our anatomy, and it probably is due to the slow rate of evolution in humans, research in genetic modification could be used to decrease athletes' predisposition to Achilles tendinopathy. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Peroneal tendon displacement accompanying intra-articular calcaneal fractures.

    PubMed

    Toussaint, Rull James; Lin, Darius; Ehrlichman, Lauren K; Ellington, J Kent; Strasser, Nicholas; Kwon, John Y

    2014-02-19

    Peroneal tendon displacement (subluxation or dislocation) accompanying an intra-articular calcaneal fracture is often undetected and under-treated. The goals of this study were to determine (1) the prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures, (2) the association of tendon displacement with fracture classifications, (3) the association of tendon displacement with heel width, and (4) the rate of missed diagnosis of the tendon displacement on radiographs and computed tomography (CT) scans and the resulting treatment rate. A retrospective radiographic review of all calcaneal fractures presenting at three institutions from June 30, 2006, to June 30, 2011, was performed. CT imaging of 421 intra-articular calcaneal fractures involving the posterior facet was available for review. The prevalence of peroneal tendon displacement was noted and its associations with fracture classification and heel width were evaluated. Peroneal tendon displacement was identified in 118 (28.0%) of the 421 calcaneal fracture cases. The presence of tendon displacement was significantly associated with joint-depression fractures compared with tongue-type fractures (p < 0.001). Only twelve (10.2%) of the 118 cases of peroneal tendon displacement had been identified in the radiology reports. Although sixty-five (55.1%) of the fractures with tendon displacement had been treated with internal fixation, the tendon displacement was treated surgically in only seven (10.8%) of these cases. Analysis of CT images showed a 28% prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures. Surgeons and radiologists are encouraged to consider this association.

  12. Subscapularis tendon tears

    PubMed Central

    Lenart, Brett A.; Ticker, Jonathan B.

    2017-01-01

    Tears of the subscapularis tendon have been under-recognised until recently. Therefore, a high index of suspicion is essential for diagnosis. A directed physical examination, including the lift-off, belly-press and increased passive external rotation can help identify tears of the subscapularis. All planes on MR imaging should be carefully evaluated to identify tears of the subscapularis, retraction, atrophy and biceps pathology. Due to the tendency of the tendon to retract medially, acute and traumatic full-thickness tears should be repaired. Chronic tears without significant degeneration should be considered for repair if no contraindication exists. Arthroscopic repair can be performed using a 30-degree arthroscope and a laterally-based single row repair; one anchor for full thickness tears ⩽ 50% of tendon length and two anchors for those ⩾ 50% of tendon length. Biceps pathology, which is invariably present, should be addressed by tenotomy or tenodesis. Timing of post-operative rehabilitation is dictated by the size of the repair and the security of the repair construct. The stages of rehabilitation typically involve a period of immobilisation followed by range of movement exercises, with a delay in active internal rotation (IR) and strengthening in IR. Cite this article: EFORT Open Rev 2017;2:484–495. DOI: 10.1302/2058-5241.2.170015 PMID:29387471

  13. [Reconstruction of chronic Achilles tendon rupture with flexor hallucis longus tendon harvested using a minimally invasive technique].

    PubMed

    Miao, Xudong; Wu, Yongping; Tao, Huimin; Yang, Disheng

    2011-07-01

    To evaluate the effectiveness of flexor hallucis longus tendon harvested using a minimally invasive technique in reconstruction of chronic Achilles tendon rupture. Between July 2006 and December 2009, 22 patients (22 feet) with chronic Achilles tendon rupture were treated, including 16 males and 6 females with a median age of 48 years (range, 28-65 years). The disease duration was 27-1,025 days (median, 51 days). Twenty-one patients had hooflike movement's history and 1 patient had no obvious inducement. The result of Thompson test was positive in 22 cases. The score was 53.04 +/- 6.75 according to American Orthopedic Foot and Ankle Society (AOFAS) ankle and hindfoot score system. MRI indicated that the gap of the chronic Achilles tendon rupture was 4.2-8.0 cm. A 3 cm-long incision was made vertically in the plantar aspect of the midfoot and a 1 cm-long transverse incision was made in a plantar flexor crease at the base of the great toe to harvest flexor hallucis longus tendon. The flexor hallucis longus tendon was 10.5-13.5 cm longer from tuber calcanei to the end of the Achilles tendon, and then the tendon was fixed to the tuber calcanei using interface screws or anchor nail after they were woven to form reflexed 3-bundle and sutured. Wound healed by first intention in all patients and no early complication occurred. Twenty-two patients were followed up 12-42 months (mean, 16.7 months). At 12 months after operation, The AOFAS ankle and hindfoot score was 92.98 +/- 5.72, showing significant difference when compared with that before operation (t= -40.903, P=0.000). The results were excellent in 18 cases, good in 2 cases, and fair in 2 cases with an excellent and good rate of 90.9%. No sural nerve injury, posterior tibial nerve injury, plantar painful scar, medial plantar nerve injury, and lateral plantar nerve injury occurred. Chronic Achilles tendon rupture reconstruction with flexor hallucis longus tendon harvested using a minimally invasive technique offers a

  14. Semitendinosus Tendon Autograft for Reconstruction of Large Defects in Chronic Achilles Tendon Ruptures.

    PubMed

    Dumbre Patil, Sampat Shivajirao; Dumbre Patil, Vaishali Sampat; Basa, Vikas Rajeshwarrao; Dombale, Ajay Birappa

    2014-07-01

    Chronic Achilles tendon ruptures are associated with considerable functional morbidity. When treated operatively, debridement of degenerated tendon ends may create large defects. Various procedures to reconstruct large defects have been described. We present a simple technique in which an autologous semitendinosus tendon graft is used to reconstruct defects larger than 5 cm in chronic Achilles tendon ruptures. The purpose of this study was to describe our operative technique and its functional outcome. Achilles ruptures of more than 6 weeks duration were considered for the study. We treated 35 patients (20 males, 15 females) with symptomatic chronic Achilles tendon ruptures. The mean age was 47.4 years (range, 30 to 59). The smallest defect that we had reconstructed was 5 cm, and the largest was 9 cm in length. The average follow-up duration was 30.7 months (range, 20 to 42). Postoperatively, the strength of gastrocsoleus was measured by manual muscle testing (MMT) in non-weight-bearing and weight-bearing positions. All operated patients showed satisfactory functional outcome, good soft tissue healing, and no reruptures. The preoperative weight-bearing MMT of 2/5 improved to 4/5 or 5/5 postoperatively. In all patients, postoperative non-weight-bearing MMT was 5/5. All patients returned to their prerupture daily activity. We present a technique that is simple, with low morbidity. We believe it is a valuable option especially when allografts are not available. It is inexpensive as suture anchors or tenodesis screws are not used. This can be a useful option if other tendons (flexor hallucis longus, peroneus brevis, etc) are not available for transfer. Level IV, retrospective case series. © The Author(s) 2014.

  15. Specialization of tendon mechanical properties results from interfascicular differences

    PubMed Central

    Thorpe, Chavaunne T.; Udeze, Chineye P.; Birch, Helen L.; Clegg, Peter D.; Screen, Hazel R. C.

    2012-01-01

    Tendons transfer force from muscle to bone. Specific tendons, including the equine superficial digital flexor tendon (SDFT), also store and return energy. For efficient function, energy-storing tendons need to be more extensible than positional tendons such as the common digital extensor tendon (CDET), and when tested in vitro have a lower modulus and failure stress, but a higher failure strain. It is not known how differences in matrix organization contribute to distinct mechanical properties in functionally different tendons. We investigated the properties of whole tendons, tendon fascicles and the fascicular interface in the high-strain energy-storing SDFT and low-strain positional CDET. Fascicles failed at lower stresses and strains than tendons. The SDFT was more extensible than the CDET, but SDFT fascicles failed at lower strains than CDET fascicles, resulting in large differences between tendon and fascicle failure strain in the SDFT. At physiological loads, the stiffness at the fascicular interface was lower in the SDFT samples, enabling a greater fascicle sliding that could account for differences in tendon and fascicle failure strain. Sliding between fascicles prior to fascicle extension in the SDFT may allow the large extensions required in energy-storing tendons while protecting fascicles from damage. PMID:22764132

  16. Specialization of tendon mechanical properties results from interfascicular differences.

    PubMed

    Thorpe, Chavaunne T; Udeze, Chineye P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2012-11-07

    Tendons transfer force from muscle to bone. Specific tendons, including the equine superficial digital flexor tendon (SDFT), also store and return energy. For efficient function, energy-storing tendons need to be more extensible than positional tendons such as the common digital extensor tendon (CDET), and when tested in vitro have a lower modulus and failure stress, but a higher failure strain. It is not known how differences in matrix organization contribute to distinct mechanical properties in functionally different tendons. We investigated the properties of whole tendons, tendon fascicles and the fascicular interface in the high-strain energy-storing SDFT and low-strain positional CDET. Fascicles failed at lower stresses and strains than tendons. The SDFT was more extensible than the CDET, but SDFT fascicles failed at lower strains than CDET fascicles, resulting in large differences between tendon and fascicle failure strain in the SDFT. At physiological loads, the stiffness at the fascicular interface was lower in the SDFT samples, enabling a greater fascicle sliding that could account for differences in tendon and fascicle failure strain. Sliding between fascicles prior to fascicle extension in the SDFT may allow the large extensions required in energy-storing tendons while protecting fascicles from damage.

  17. Anterior cruciate ligament reconstruction: principles of treatment

    PubMed Central

    Paschos, Nikolaos K.; Howell, Stephen M.

    2016-01-01

    Anterior cruciate ligament (ACL) reconstruction is one of the most common procedures in sports medicine. Several areas of controversy exist in ACL tear management which have engaged surgeons and researchers in debates towards identifying an ideal approach for these patients. This instructional review discusses the principles of ACL reconstruction in an attempt to provide guidelines and initiate a critical thinking approach on the most common areas of controversy regarding ACL reconstruction. Using high-level evidence from the literature, as presented in randomised controlled trials, systematic reviews, and meta-analyses, operative versus conservative treatment, timing of surgery, and rehabilitation are discussed. Also, the advantages and disadvantages of the most common types of autografts, such as patellar tendon and hamstrings as well as allografts are presented. Key considerations for the anatomical, histological, biomechanical and clinical data (‘IDEAL’) graft positioning are reviewed. Cite this article: Paschos NK, Howell SM. Anterior cruciate ligament reconstruction: principles of treatment. EFORT Open Rev 2016;398-408. DOI: 10.1302/2058-5241.1.160032. PMID:28461919

  18. The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons

    PubMed Central

    Thorpe, Chavaunne T.; Godinho, Marta S.C.; Riley, Graham P.; Birch, Helen L.; Clegg, Peter D.; Screen, Hazel R.C.

    2015-01-01

    While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy storage and return. In the equine forelimb, the energy storing superficial digital flexor tendon (SDFT) has much higher failure strains than the positional common digital extensor tendon (CDET). However, we have previously shown that this is not due to differences in the properties of the SDFT and CDET fascicles (the largest tendon subunits). Instead, there is a greater capacity for interfascicular sliding in the SDFT which facilitates the greater extensions in this particular tendon (Thorpe et al., 2012). In the current study, we exposed fascicles and interfascicular matrix (IFM) from the SDFT and CDET to cyclic loading followed by a test to failure. The results show that IFM mechanical behaviour is not a result of irreversible deformation, but the IFM is able to withstand cyclic loading, and is more elastic in the SDFT than in the CDET. We also assessed the effect of ageing on IFM properties, demonstrating that the IFM is less able to resist repetitive loading as it ages, becoming stiffer with increasing age in the SDFT. These results provide further indications that the IFM is important for efficient function in energy storing tendons, and age-related alterations to the IFM may compromise function and predispose older tendons to injury. PMID:25958330

  19. The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons.

    PubMed

    Thorpe, Chavaunne T; Godinho, Marta S C; Riley, Graham P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2015-12-01

    While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy storage and return. In the equine forelimb, the energy storing superficial digital flexor tendon (SDFT) has much higher failure strains than the positional common digital extensor tendon (CDET). However, we have previously shown that this is not due to differences in the properties of the SDFT and CDET fascicles (the largest tendon subunits). Instead, there is a greater capacity for interfascicular sliding in the SDFT which facilitates the greater extensions in this particular tendon (Thorpe et al., 2012). In the current study, we exposed fascicles and interfascicular matrix (IFM) from the SDFT and CDET to cyclic loading followed by a test to failure. The results show that IFM mechanical behaviour is not a result of irreversible deformation, but the IFM is able to withstand cyclic loading, and is more elastic in the SDFT than in the CDET. We also assessed the effect of ageing on IFM properties, demonstrating that the IFM is less able to resist repetitive loading as it ages, becoming stiffer with increasing age in the SDFT. These results provide further indications that the IFM is important for efficient function in energy storing tendons, and age-related alterations to the IFM may compromise function and predispose older tendons to injury. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Muscle-tendon glucose uptake in Achilles tendon rupture and tendinopathy before and after eccentric rehabilitation: Comparative case reports.

    PubMed

    Masood, Tahir; Kalliokoski, Kari; Bojsen-Møller, Jens; Finni, Taija

    2016-09-01

    Achilles tendon rupture (ATR) is the most common tendon rupture injury. The consequences of ATR on metabolic activity of the Achilles tendon and ankle plantarflexors are unknown. Furthermore, the effects of eccentric rehabilitation on metabolic activity patterns of Achilles tendon and ankle plantarflexors in ATR patients have not been reported thus far. We present a case study demonstrating glucose uptake (GU) in the Achilles tendon, the triceps surae, and the flexor hallucis longus of a post-surgical ATR patient before and after a 5-month eccentric rehabilitation. At baseline, three months post-surgery, all muscles and Achilles tendon displayed much higher GU in the ATR patient compared to a healthy individual despite lower plantarflexion force. After the rehabilitation, plantarflexion force increased in the operated leg while muscle GU was considerably reduced. The triceps surae muscles showed similar values to the healthy control. When compared to the healthy or a matched patient with Achilles tendon pain after 12 weeks of rehabilitation, Achilles tendon GU levels of ATR patient remained greater after the rehabilitation. Past studies have shown a shift in the metabolic fuel utilization towards glycolysis due to immobilization. Further research, combined with immuno-histological investigation, is needed to fully understand the mechanism behind excessive glucose uptake in ATR cases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Rat supraspinatus muscle atrophy after tendon detachment.

    PubMed

    Barton, Elisabeth R; Gimbel, Jonathan A; Williams, Gerald R; Soslowsky, Louis J

    2005-03-01

    Rotator cuff tears are one of the most common tendon disorders found in the healthy population. Tendon tears not only affect the biomechanical properties of the tendon, but can also lead to debilitation of the muscles attached to the damaged tendons. The changes that occur in the muscle after tendon detachment are not well understood. A rat rotator cuff model was utilized to determine the time course of changes that occur in the supraspinatus muscle after tendon detachment. It was hypothesized that the lack of load on the supraspinatus muscle would cause a significant decrease in muscle mass and a conversion of muscle fiber properties toward those of fast fiber types. Tendons were detached at the insertion on the humerus without repair. Muscle mass, morphology and fiber properties were measured at one, two, four, eight, and 16 weeks after detachment. Tendon detachment resulted in a rapid loss of muscle mass, an increase in the proportion of fast muscle fibers, and an increase in the fibrotic content of the muscle bed, concomitant with the appearance of adhesions of the tendon to surrounding surfaces. At 16 weeks post-detachment, muscle mass and the fiber properties in the deep muscle layers returned to normal levels. However, the fiber shifts observed in the superficial layers persisted throughout the experiment. These results suggest that load returned to the muscle via adhesions to surrounding surfaces, which may be sufficient to reverse changes in muscle mass.

  2. The flexor digitorum profundus "demi-tendon"--a new technique for passage of the flexor profundus tendon through the A4 pulley.

    PubMed

    Elliot, D; Khandwala, A R; Ragoowansi, R

    2001-10-01

    The flexor digitorum profundus (FDP) tendon may retract after avulsion or division in Zone 1. When treatment has been delayed, the oedematous tendon can be too swollen to pass freely through the A4 pulley. We present a new technique for dealing with this situation which depends on the "double-barrelled" nature of the distal part of the FDP tendon. One half of the tendon is excised longitudinally and the remaining "demi-tendon" is passed through the intact A4 pulley to allow tendon repair or re-attachment. This technique has been used in six cases in which passage of the FDP tendon through the A4 pulley would otherwise have been impossible. Copyright 2001 The British Society for Surgery of the Hand.

  3. Muscle contributions to medial tibiofemoral compartment contact loading following ACL reconstruction using semitendinosus and gracilis tendon grafts.

    PubMed

    Konrath, Jason M; Saxby, David J; Killen, Bryce A; Pizzolato, Claudio; Vertullo, Christopher J; Barrett, Rod S; Lloyd, David G

    2017-01-01

    The muscle-tendon properties of the semitendinosus (ST) and gracilis (GR) are substantially altered following tendon harvest for the purpose of anterior cruciate ligament reconstruction (ACLR). This study adopted a musculoskeletal modelling approach to determine how the changes to the ST and GR muscle-tendon properties alter their contribution to medial compartment contact loading within the tibiofemoral joint in post ACLR patients, and the extent to which other muscles compensate under the same external loading conditions during walking, running and sidestep cutting. Motion capture and electromyography (EMG) data from 16 lower extremity muscles were acquired during walking, running and cutting in 25 participants that had undergone an ACLR using a quadruple (ST+GR) hamstring auto-graft. An EMG-driven musculoskeletal model was used to estimate the medial compartment contact loads during the stance phase of each gait task. An adjusted model was then created by altering muscle-tendon properties for the ST and GR to reflect their reported changes following ACLR. Parameters for the other muscles in the model were calibrated to match the experimental joint moments. The medial compartment contact loads for the standard and adjusted models were similar. The combined contributions of ST and GR to medial compartment contact load in the adjusted model were reduced by 26%, 17% and 17% during walking, running and cutting, respectively. These deficits were balanced by increases in the contribution made by the semimembranosus muscle of 33% and 22% during running and cutting, respectively. Alterations to the ST and GR muscle-tendon properties in ACLR patients resulted in reduced contribution to medial compartment contact loads during gait tasks, for which the semimembranosus muscle can compensate.

  4. A novel biodegradable PCL film for tendon reconstruction: Achilles tendon defect model in rats.

    PubMed

    Kazimoğlu, C; Bölükbaşi, S; Kanatli, U; Senköylü, A; Altun, N S; Babaç, C; Yavuz, H; Pişkin, E

    2003-09-01

    This study aims to investigate applicability of poly(epsilon-caprolactone) (PCL) biodegradable films for repair of gaps in Achilles tendons in a rat model, also comparing surgical repair versus no repair approaches. PCL was synthesized with tailor-made properties, then, PCL films were prepared by solvent casting. Seventy-five outbred Sprague-Dawley rats were randomly allocated into five groups: (i) sham operated (skin incision only); (ii) no repair (complete division of the Achilles tendon and plantaris tendon without repair); (iii) Achilles repair (with a modified Kessler type suture); and (iv) plasty of Achilles tendon defects with the biodegradable PCL films, and (v) animals subjected to 1 cm mid-substance defect with no repair. Functional performance was determined from the measurements of hindpaw prints utilizing the Achilles functional index. The animals were killed 8 weeks after surgery and histological and biomechanical evaluations were made. All groups subjected to Achilles tendon division had a significant functional impairment that gradually improved so that by day 28 there were no functional impairments in any group whereas animals with a defect remained impaired. The magnitude of the biomechanical and morphological changes at postoperative 8 weeks were similar for no repair group (conservative), Achilles repair group and tendonplasty group (biodegradable PCL film group). The initial rate of functional recovery was significantly different for primary suture, Achilles repair group and PCL film group (p>0.01). But, at the 28th day, functional recovery was quite similar to the other groups. In summary, our results suggest that the PCL film can be an alternative biomaterial for tendon replacement.

  5. Healing of donor site in bone-tendon-bone ACL reconstruction accelerated with plasma rich in growth factors: a randomized clinical trial.

    PubMed

    Seijas, Roberto; Rius, Marta; Ares, Oscar; García-Balletbó, Montserrat; Serra, Iván; Cugat, Ramón

    2015-04-01

    To determine whether the use of plasma rich in growth factors accelerates healing of the donor site in bone-tendon-bone anterior cruciate ligament (ACL) reconstruction (patellar graft). The use of the patellar graft presents post-operative problems such as anterior knee pain, which limits its use and leads to preference being taken for alternative grafts. A double-blind, randomized, clinical trial was performed comparing two groups of patients who underwent ACL reconstruction using patellar tendon graft and comparing the use of plasma rich in growth factors at the donor site after graft harvest in terms of local regeneration by ultrasound assessment. The plasma rich in growth factors group shows earlier donor site regeneration in comparison with the control group (2 months earlier), with significant differences in the first 4 months of the follow-up. The application of plasma rich in growth factors shows accelerated tissue regeneration processes with respect to the control group. This fact, together with the previously published with similar conclusions, can create a knowledge basis in order to set out new recovery guidelines following ACL reconstruction. Therapeutic study, Level I.

  6. Relationship between metabolic cost and muscular coactivation across running speeds.

    PubMed

    Moore, Isabel S; Jones, Andrew M; Dixon, Sharon J

    2014-11-01

    Muscular coactivation can help stabilise a joint, but contrasting results in previous gait studies highlight that it is not clear whether this is metabolically beneficial. The aim was to assess the relationship between the metabolic cost of running and muscular coactivation across different running speeds, in addition to assessing the reliability and precision of lower limb muscular coactivation. Eleven female recreational runners visited the laboratory on two separate occasions. On both occasions subjects ran at three speeds (9.1, 11 and 12 km h(-1)) for six minutes each. Oxygen consumption and electromyographic data were simultaneously recorded during the final two minutes of each speed. Temporal coactivations of lower limb muscles during the stance phase were calculated. Five muscles were assessed: rectus femoris, vastus lateralis, biceps femoris, tibialis anterior and gastrocnemius lateralis. Nonparametric correlations revealed at least one significant, positive association between lower limb muscular coactivation and the metabolic cost of running for each speed. The length of tibialis anterior activation and muscular coactivation of the biceps femoris-tibialis anterior and gastrocnemius lateralis-tibialis anterior decreased with speed. These results show that longer coactivations of the proximal (rectus femoris-biceps femoris and vastus lateralis-biceps femoris) and leg extensor (rectus femoris-gastrocnemius lateralis) muscles were related to a greater metabolic cost of running, which could be detrimental to performance. The decrease in coactivation in the flexor and distal muscles at faster speeds occurs due to the shorter duration of tibialis anterior activation as speed increases, yet stability may be maintained. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  7. Higher anterior knee laxity influences the landing biomechanics displayed by pubescent girls.

    PubMed

    Wild, Catherine Y; Munro, Bridget J; Steele, Julie R

    2017-01-01

    Despite an increase in anterior knee laxity (AKL) during the adolescent growth spurt in girls, it is unknown whether landing biomechanics are affected by this change. This study investigated whether pubescent girls with higher AKL displayed differences in their lower limb strength or landing biomechanics when performing a horizontal leap movement compared to girls with lower AKL. Forty-six pubescent girls (10-13 years) were tested at the time of their peak height velocity (PHV). Passive AKL was quantified and used to classify participants into higher (HAKL; peak displacement > 4 mm) and lower (LAKL; peak displacement < 3 mm) AKL groups (n = 15/group). Three-dimensional kinematics, ground reaction forces (GRF) and muscle activation patterns were assessed during a horizontal leap landing. HAKL participants displayed significantly (P < 0.05) reduced hip abduction, increased hip abduction moments, as well as earlier hamstring muscle and later tibialis anterior activation compared to LAKL participants. Girls with HAKL displayed compensatory landing biomechanics, which are suggested to assist the functional stability of their knees during this dynamic task. Further research is warranted, however, to confirm or refute this notion.

  8. Response to Tendon Vibration Questions the Underlying Rationale of Proprioceptive Training

    PubMed Central

    Lubetzky, Anat Vilnai; McCoy, Sarah Westcott; Price, Robert; Kartin, Deborah

    2017-01-01

    Context: Proprioceptive training on compliant surfaces is used to rehabilitate and prevent ankle sprains. The ability to improve proprioceptive function via such training has been questioned. Achilles tendon vibration is used in motor-control research as a form of proprioceptive stimulus. Using measures of postural steadiness with nonlinear measures to elucidate control mechanisms, tendon vibration can be applied to investigate the underlying rationale of proprioceptive training. Objective: To test whether the effect of vibration on young adults' postural control depended on the support surface. Design: Descriptive laboratory study. Setting: Research laboratory. Patients or Other Participants: Thirty healthy adults and 10 adults with chronic ankle instability (CAI; age range = 18−40 years). Intervention(s): With eyes open, participants stood in bilateral stance on a rigid plate (floor), memory foam, and a Both Sides Up (BOSU) ball covering a force platform. We applied bilateral Achilles tendon vibration for the middle 20 seconds in a series of 60-second trials and analyzed participants' responses from previbration to vibration (pre-vib) and from vibration to postvibration (vib-post). Main Outcome Measure(s): We calculated anterior-posterior excursion of the center of pressure and complexity index derived from the area under multiscale entropy curves. Results: The excursion response to vibration differed by surface, as indicated by a significant interaction of P < .001 for the healthy group at both time points and for the CAI group vib-post. Although both groups demonstrated increased excursion from pre-vib and from vib-post, a decrease was observed on the BOSU. The complexity response to vibration differed by surface for the healthy group (pre-vib, P < .001). The pattern for the CAI group was similar but not significant. Complexity changes vib-post were the same on all surfaces for both groups. Conclusions: Participants reacted less to ankle vibration when

  9. Response to Tendon Vibration Questions the Underlying Rationale of Proprioceptive Training.

    PubMed

    Lubetzky, Anat Vilnai; McCoy, Sarah Westcott; Price, Robert; Kartin, Deborah

    2017-02-01

    Proprioceptive training on compliant surfaces is used to rehabilitate and prevent ankle sprains. The ability to improve proprioceptive function via such training has been questioned. Achilles tendon vibration is used in motor-control research as a form of proprioceptive stimulus. Using measures of postural steadiness with nonlinear measures to elucidate control mechanisms, tendon vibration can be applied to investigate the underlying rationale of proprioceptive training. To test whether the effect of vibration on young adults' postural control depended on the support surface. Descriptive laboratory study. Research laboratory. Thirty healthy adults and 10 adults with chronic ankle instability (CAI; age range = 18-40 years). With eyes open, participants stood in bilateral stance on a rigid plate (floor), memory foam, and a Both Sides Up (BOSU) ball covering a force platform. We applied bilateral Achilles tendon vibration for the middle 20 seconds in a series of 60-second trials and analyzed participants' responses from previbration to vibration (pre-vib) and from vibration to postvibration (vib-post). We calculated anterior-posterior excursion of the center of pressure and complexity index derived from the area under multiscale entropy curves. The excursion response to vibration differed by surface, as indicated by a significant interaction of P < .001 for the healthy group at both time points and for the CAI group vib-post. Although both groups demonstrated increased excursion from pre-vib and from vib-post, a decrease was observed on the BOSU. The complexity response to vibration differed by surface for the healthy group (pre-vib, P < .001). The pattern for the CAI group was similar but not significant. Complexity changes vib-post were the same on all surfaces for both groups. Participants reacted less to ankle vibration when standing on the BOSU as compared with the floor, suggesting that proprioceptive training may not be occurring. Different balance

  10. Fibrocartilage associated with human tendons and their pulleys.

    PubMed Central

    Benjamin, M; Qin, S; Ralphs, J R

    1995-01-01

    The presence of fibrocartilage in tendons that wrap around bony or fibrous pulleys is well known. It is an adaptation to resisting compression or shear, but the extent to which the structure of most human tendons is modified where they contact pulleys is less clear, for there has been no single comprehensive survey of a large number of sites. Less is known of the structure of the corresponding pulleys. In the present study, 38 regions of tendons that wrap around bony pulleys or pass beneath fibrous retinacula have been studied in routine histology sections taken from each of 2 or 3 elderly dissecting room cadavers. Most of the corresponding pulleys have also been examined. Fibrocartilage was present in 22 of the 38 tendon sites and it was most conspicuous where the tendons pressed predominantly against bone rather than retinacula and where they showed a large change in direction. Fibrocartilage was more characteristic of tendons at the ankle than the wrist, probably because the long axis of the foot is at right angles to that of the leg. There was considerable variation in the structure of tendon fibrocartilage. The most fibrocartilaginous tendons had oval or round cells embedded in a highly metachromatic matrix with interwoven or spiralling collagen fibres. At other sites, fibrocartilage cells were arranged in rows between parallel collagen fibres. The differences probably relate to differences in development. A single tendon could be modified at successive points along its length and fibrocartilage could be present in the endotenon and epitenon as well as in the tendon itself. Pathological changes seen in 'wrap around' tendons were fragmentation and partial delamination of the compressed surface, chondrocyte clustering, fatty infiltration and bone formation. Three types of pulleys were described for tendons--bony prominences and grooves, fibrous retinacula and synovial joints. The extent of cartilaginous differentiation on the periosteum of bony pulleys

  11. Achilles Tendon Rupture: Avoiding Tendon Lengthening during Surgical Repair and Rehabilitation

    PubMed Central

    Maquirriain, Javier

    2011-01-01

    Achilles tendon rupture is a serious injury for which the best treatment is still controversial. Its primary goal should be to restore normal length and tension, thus obtaining an optimal function. Tendon elongation correlates significantly with clinical outcome; lengthening is an important cause of morbidity and may produce permanent functional impairment. In this article, we review all factors that may influence the repair, including the type of surgical technique, suture material, and rehabilitation program, among many others. PMID:21966048

  12. The revitalisation of flexor tendon allografts with bone marrow stromal cells and mechanical stimulation: An ex vivo model revitalising flexor tendon allografts.

    PubMed

    Wu, J H; Thoreson, A R; Gingery, A; An, K N; Moran, S L; Amadio, P C; Zhao, C

    2017-03-01

    The present study describes a novel technique for revitalising allogenic intrasynovial tendons by combining cell-based therapy and mechanical stimulation in an ex vivo canine model. Specifically, canine flexor digitorum profundus tendons were used for this study and were divided into the following groups: (1) untreated, unprocessed normal tendon; (2) decellularised tendon; (3) bone marrow stromal cell (BMSC)-seeded tendon; and (4) BMSC-seeded and cyclically stretched tendon. Lateral slits were introduced on the tendon to facilitate cell seeding. Tendons from all four study groups were distracted by a servohydraulic testing machine. Tensile force and displacement data were continuously recorded at a sample rate of 20 Hz until 200 Newton of force was reached. Before testing, the cross-sectional dimensions of each tendon were measured with a digital caliper. Young's modulus was calculated from the slope of the linear region of the stress-strain curve. The BMSCs were labeled for histological and cell viability evaluation on the decellularized tendon scaffold under a confocal microscope. Gene expression levels of selected extracellular matrix tendon growth factor genes were measured. Results were reported as mean ± SD and data was analyzed with one-way ANOVAs followed by Tukey's post hoc multiple-comparison test. We observed no significant difference in cross-sectional area or in Young's modulus among the four study groups. In addition, histological sections showed that the BMSCs were aligned well and viable on the tendon slices after two-week culture in groups three and four. Expression levels of several extracellular matrix tendon growth factors, including collagen type I, collagen type III, and matrix metalloproteinase were significantly higher in group four than in group three (p < 0.05). Lateral slits introduced into de-cellularised tendon is a promising method of delivery of BMSCs without compromising cell viability and tendon mechanical properties. In addition

  13. Kinetics and Kinematics after the Bridle Procedure for Treatment of Traumatic Foot Drop

    PubMed Central

    Hastings, Mary K.; Sinacore, David R.; Woodburn, James; Paxton, E. Scott; Klein, Sandra E.; McCormick, Jeremy J.; Bohnert, Kathryn L.; Beckert, Krista S.; Stein, Michelle L.; Strube, Michael J; Johnson, Jeffrey E.

    2014-01-01

    Background The Bridle procedure restores active ankle dorsiflexion through a tri-tendon anastamosis of the tibialis posterior, transferred to the dorsum of the foot, with the peroneus longus and tibialis anterior tendon. Inter-segmental foot motion after the Bridle procedure has not been measured. The purpose of this study is to report kinetic and kinematic variables during walking and heel rise in patients after the Bridle procedure. Methods 18 Bridle and 10 control participants were studied. Walking and heel rise kinetic and kinematic variables were collected and compared using an ANOVA. Findings During walking the Bridle group, compared with controls, had reduced ankle power at push off [2.3 (SD 0.7) W/kg, 3.4 (SD 0.6) W/kg, respectively, P<.01], less hallux extension during swing [−13 (SD 7)°, 15 (SD6)°, respectively, P<.01] and slightly less ankle dorsiflexion during swing [6 (SD4)°, 9 (SD 2)°, respectively, P=.03]. During heel rise the Bridle group had 4 (SD 6)° of forefoot on hindfoot dorsiflexion compared to 8 (SD 3)° of plantarflexion in the controls (P<.01). Interpretation This study provides evidence that the Bridle procedure restores the majority of dorsiflexion motion during swing. However, plantarflexor function during push off and hallux extension during swing were reduced during walking in the Bridle group. Abnormal mid-tarsal joint motion, forefoot on hindfoot dorsiflexion instead of plantarflexion, was identified in the Bridle group during the more challenging heel rise task. Intervention after the Bridle procedure must maximize ankle plantarflexor function and midfoot motion should be examined during challenging tasks. PMID:23684087

  14. Shear load transfer in high and low stress tendons.

    PubMed

    Kondratko-Mittnacht, Jaclyn; Duenwald-Kuehl, Sarah; Lakes, Roderic; Vanderby, Ray

    2015-05-01

    Tendon is an integral part of joint movement and stability, as it functions to transmit load from muscle to bone. It has an anisotropic, fibrous hierarchical structure that is generally loaded in the direction of its fibers/fascicles. Internal load distributions are altered when joint motion rotates an insertion site or when local damage disrupts fibers/fascicles, potentially causing inter-fiber (or inter-fascicular) shear. Tendons with different microstructures (helical versus linear) may redistribute loads differently. This study explored how shear redistributes axial loads in rat tail tendon (low stress tendons with linear microstructure) and porcine flexor tendon (high stress with helical microstructure) by creating lacerations on opposite sides of the tendon, ranging from about 20% to 60% of the tendon width, to create various magnitudes of shear. Differences in fascicular orientation were quantified using polarized light microscopy. Unexpectedly, both tendon types maintained about 20% of pre-laceration stress values after overlapping cuts of 60% of tendon width (no intact fibers end to end) suggesting that shear stress transfer can contribute more to overall tendon strength and stiffness than previously reported. All structural parameters for both tendon types decreased linearly with increasing laceration depth. The tail tendon had a more rapid decline in post-laceration elastic stress and modulus parameters as well as a more linear and less tightly packed fascicular structure, suggesting that positional tendons may be less well suited to redistribute loads via a shear mechanism. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Shear Load Transfer in High and Low Stress Tendons

    PubMed Central

    Kondratko-Mittnacht, Jaclyn; Duenwald-Kuehl, Sarah; Lakes, Roderic; Vanderby, Ray

    2016-01-01

    Background Tendon is an integral part of joint movement and stability, as it functions to transmit load from muscle to bone. It has an anisotropic, fibrous hierarchical structure that is generally loaded in the direction of its fibers/fascicles. Internal load distributions are altered when joint motion rotates an insertion site or when local damage disrupts fibers/fascicles, potentially causing inter-fiber (or inter-fascicular) shear. Tendons with different microstructure (helical versus linear) may redistribute loads differently. Method of Approach This study explored how shear redistributes axial loads in rat tail tendon (low stress tendons with linear microstructure) and porcine flexor tendon (high stress with helical microstructure) by creating lacerations on opposite sides of the tendon, ranging from about 20-60% of the tendon width, to create various magnitudes of shear. Differences in fascicular orientation were quantified using polarized light microscopy. Results and Conclusions Unexpectedly, both tendon types maintained about 20% of pre-laceration stress values after overlapping cuts of 60% of tendon width (no intact fibers end to end) suggesting that shear stress transfer can contribute more to overall tendon strength and stiffness than previously reported. All structural parameters for both tendon types decreased linearly with increasing laceration depth. The tail tendon had a more rapid decline in post-laceration elastic stress and modulus parameters as well as a more linear and less tightly packed fascicular structure, suggesting that positional tendons may be less well suited to redistribute loads via a shear mechanism. PMID:25700261

  16. Matrix metabolism rate differs in functionally distinct tendons.

    PubMed

    Birch, Helen L; Worboys, Sarah; Eissa, Sabry; Jackson, Brendan; Strassburg, Sandra; Clegg, Peter D

    2008-04-01

    Tendon matrix integrity is vital to ensure adequate mechanical properties for efficient function. Although historically tendon was considered to be relatively inert, recent studies have shown that tendon matrix turnover is active. During normal physiological activities some tendons are subjected to stress and strains much closer to their failure properties than others. Tendons with low safety margins are those which function as energy stores such as the equine superficial digital flexor tendon (SDFT) and human Achilles tendon (AT). We postulate therefore that energy storing tendons suffer a higher degree of micro-damage and thus have a higher rate of matrix turnover than positional tendons. The hypothesis was tested using tissue from the equine SDFT and common digital extensor tendon (CDET). Matrix turnover was assessed indirectly by a combination of measurements for matrix age, markers of degradation, potential for degradation and protein expression. Results show that despite higher cellularity, the SDFT has lower relative levels of mRNA for collagen types I and III. Non-collagenous proteins, although expressed at different levels per cell, do not appear to differ between tendon types. Relative levels of mRNA for MMP1, MMP13 and both pro-MMP3 and MMP13 protein activity were significantly higher in the CDET. Correspondingly levels of cross-linked carboxyterminal telopeptide of type I collagen (ICTP) were higher in the CDET and tissue fluorescence lower suggesting more rapid turnover of the collagenous component. Reduced or inhibited collagen turnover in the SDFT may account for the high level of degeneration and subsequent injury compared to the CDET.

  17. Evaluating Changes in Tendon Crimp with Fatigue Loading as an ex vivo Structural Assessment of Tendon Damage

    PubMed Central

    Freedman, Benjamin R.; Zuskov, Andrey; Sarver, Joseph J.; Buckley, Mark R.; Soslowsky, Louis J.

    2015-01-01

    The complex structure of tendons relates to their mechanical properties. Previous research has associated the waviness of collagen fibers (crimp) during quasi-static tensile loading to tensile mechanics, but less is known about the role of fatigue loading on crimp properties. In this study (IACUC approved), mouse patellar tendons were fatigue loaded while an integrated plane polariscope simultaneously assessed crimp properties. We demonstrate a novel structural mechanism whereby tendon crimp amplitude and frequency are altered with fatigue loading. In particular, fatigue loading increased the crimp amplitude across the tendon width and length, and these structural alterations were shown to be both region and load dependent. The change in crimp amplitude was strongly correlated to mechanical tissue laxity (defined as the ratio of displacement and gauge length relative to the first cycle of fatigue loading assessed at constant load throughout testing), at all loads and regions evaluated. Together, this study highlights the role of fatigue loading on tendon crimp properties as a function of load applied and region evaluated, and offers an additional structural mechanism for mechanical alterations that may lead to ultimate tendon failure. PMID:25773654

  18. Minimally invasive reconstruction of chronic achilles tendon ruptures using the ipsilateral free semitendinosus tendon graft and interference screw fixation.

    PubMed

    Maffulli, Nicola; Loppini, Mattia; Longo, Umile Giuseppe; Maffulli, Gayle D; Denaro, Vincenzo

    2013-05-01

    Achilles tendon ruptures represent more than 40% of all tendon ruptures requiring surgical management. About 20% of acute Achilles tendon tears are not diagnosed at the time of injury and become chronic, necessitating more complicated management than fresh injuries. Several techniques for the reconstruction of chronic tears of the Achilles tendon have been described, but the superiority of one technique over the others has not been demonstrated. Mini-invasive reconstruction of the Achilles tendon, with a gap lesion larger than 6 cm, using the ipsilateral free semitendinosus tendon graft will result in improvement of the overall function with a low rate of complications. Case series; Level of evidence, 4. Between 2008 and 2010, the authors prospectively enrolled 28 consecutive patients (21 men and 7 women; median age, 46 years) with chronic closed ruptures of the Achilles tendon who had undergone reconstruction with a free semitendinosus tendon graft. They assessed the Achilles tendon Total Rupture Score (ATRS), maximum calf circumference, and isometric plantarflexion strength before surgery and at the last follow-up. Outcome of surgery and rate of complications were also recorded. The median follow-up after surgery was 31.4 months. The overall result of surgery was excellent/good in 26 (93%) of 28 patients. The ATRS improved from 42 (range, 29-55) to 86 (range, 78-95) (P < .0001). In the operated leg, the maximum calf circumference and isometric plantarflexion strength were significantly improved after surgery (P < .0001); however, their values remained significantly lower than those of the opposite side (P < .0001). All patients were able to walk on tiptoes and returned to their preinjury working occupation. No infections were recorded. Mini-invasive reconstruction of the Achilles tendon, with a gap lesion larger than 6 cm, using the ipsilateral free semitendinosus tendon graft provides a significant improvement of symptoms and function, although calf

  19. Anatomic findings and complications after surgical treatment of chronic, partial distal biceps tendon tears: a case cohort comparison study.

    PubMed

    Ruch, David S; Watters, Tyler Steven; Wartinbee, Daniel A; Richard, Marc J; Leversedge, Fraser J; Mithani, Suhail K

    2014-08-01

    To describe pertinent anatomic findings during repair of chronic, partial distal biceps tendon tears and to compare the complications of surgery with a similar cohort of acute, complete tears. Group 1 included 14 patients (15 elbows) with partial tears managed operatively an average of 10 months from onset of injury or symptoms. Group 2 included a matched cohort of 16 patients (17 elbows) treated for complete, acute tears an average of 19 days from injury. A retrospective review of all 30 patients focused on demographic data, intraoperative findings, and postoperative complications. A single, anterior incision was used in all cases with multiple suture anchors or a bicortical toggling button for fixation of the repair. We evaluated 27 men and 3 women with an average age of 55 years (group 1) and 48 years (group 2). Intratendinous ganglion formation at the site of rupture of the degenerative tendon was observed in 5 cases of partial tears and none of the complete tears. Partial tears involved the lateral aspect or short head of the biceps tendon insertion in all cases. Postoperative complications included lateral antebrachial cutaneous nerve neuritis in 8 group 1 patients and 6 group 2 patients and transient posterior interosseus nerve palsy in 3 group 1 patients. Partial distal biceps tendon ruptures showed a consistent pattern of pathology involving disruption of the lateral side of the tendon insertion involving the small head of the biceps. Degenerative intratendinous ganglion formation was present in one third of cases. Repair of chronic, partial distal biceps tendon injuries may have a higher incidence of posterior interosseous and lateral antebrachial cutaneous nerve palsies. Therapeutic III. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  20. Genome-wide association screens for Achilles tendon and ACL tears and tendinopathy

    PubMed Central

    Roos, Thomas R.; Roos, Andrew K.; Kleimeyer, John P.; Ahmed, Marwa A.; Goodlin, Gabrielle T.; Fredericson, Michael; Ioannidis, John P. A.; Avins, Andrew L.; Dragoo, Jason L.

    2017-01-01

    Achilles tendinopathy or rupture and anterior cruciate ligament (ACL) rupture are substantial injuries affecting athletes, associated with delayed recovery or inability to return to competition. To identify genetic markers that might be used to predict risk for these injuries, we performed genome-wide association screens for these injuries using data from the Genetic Epidemiology Research on Adult Health and Aging (GERA) cohort consisting of 102,979 individuals. We did not find any single nucleotide polymorphisms (SNPs) associated with either of these injuries with a p-value that was genome-wide significant (p<5x10-8). We found, however, four and three polymorphisms with p-values that were borderline significant (p<10−6) for Achilles tendon injury and ACL rupture, respectively. We then tested SNPs previously reported to be associated with either Achilles tendon injury or ACL rupture. None showed an association in our cohort with a false discovery rate of less than 5%. We obtained, however, moderate to weak evidence for replication in one case; specifically, rs4919510 in MIR608 had a p-value of 5.1x10-3 for association with Achilles tendon injury, corresponding to a 7% chance of false replication. Finally, we tested 2855 SNPs in 90 candidate genes for musculoskeletal injury, but did not find any that showed a significant association below a false discovery rate of 5%. We provide data containing summary statistics for the entire genome, which will be useful for future genetic studies on these injuries. PMID:28358823

  1. Kinesthetic illusions attenuate experimental muscle pain, as do muscle and cutaneous stimulation.

    PubMed

    Gay, André; Aimonetti, Jean-Marc; Roll, Jean-Pierre; Ribot-Ciscar, Edith

    2015-07-30

    In the present study, muscle pain was induced experimentally in healthy subjects by administrating hypertonic saline injections into the tibialis anterior (TA) muscle. We first aimed at comparing the analgesic effects of mechanical vibration applied to either cutaneous or muscle receptors of the TA or to both types simultaneously. Secondly, pain alleviation was compared in subjects in whom muscle tendon vibration evoked kinesthetic illusions of the ankle joint. Muscle tendon vibration, which primarily activated muscle receptors, reduced pain intensity by 30% (p<0.01). In addition, tangential skin vibration reduced pain intensity by 33% (p<0.01), primarily by activating cutaneous receptors. Concurrently stimulating both sensory channels induced stronger analgesic effects (-51%, p<0.01), as shown by the lower levels of electrodermal activity. The strongest analgesic effects of the vibration-induced muscle inputs occurred when illusory movements were perceived (-38%, p=0.01). The results suggest that both cutaneous and muscle sensory feedback reduce muscle pain, most likely via segmental and supraspinal processes. Further clinical trials are needed to investigate these new methods of muscle pain relief. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Reconstruction of a ruptured patellar tendon using ipsilateral semitendinosus and gracilis tendons with preserved distal insertions: two case reports

    PubMed Central

    2013-01-01

    Background Acute patellar tendon ruptures with poor tissue quality. Ruptures that have been neglected are difficult to repair. Several surgical techniques for the repair of the patellar tendon have been reported, however, these techniques remain difficult because of contractures, adhesions, and atrophy of the quadriceps muscle after surgery. Case presentation We report the cases of 2 Japanese patients (Case 1: a 16-year-old male and Case 2: a 43-year-old male) with patellar tendon ruptures who were treated by reconstruction using semitendinosus-gracilis (STG) tendons with preserved distal insertions. Retaining the original insertion of the STG appears to preserve its viability and provide the revascularization necessary to accelerate healing. Both tendons were placed in front of the patella, in a figure-of-eight fashion, providing stability to the patella. Conclusion Both patients recovered near normal strength and stability of the patellar tendon as well as restoration of function after the operation. PMID:24010848

  3. Using the zebrafish to understand tendon development and repair

    PubMed Central

    Chen, Jessica W.; Galloway, Jenna L.

    2017-01-01

    Tendons are important components of our musculoskeletal system. Injuries to these tissues are very common, resulting from occupational-related injuries, sports-related trauma, and age-related degeneration. Unfortunately, there are few treatment options, and current therapies rarely restore injured tendons to their original function. An improved understanding of the pathways regulating their development and repair would have significant impact in stimulating the formulation of regenerative-based approaches for tendon injury. The zebrafish provides an ideal system in which to perform genetic and chemical screens to identify new pathways involved in tendon biology. Until recently, there had been few descriptions of tendons and ligaments in the zebrafish and their similarity to mammalian tendon tissues. In this chapter, we describe the development of the zebrafish tendon and ligament tissues in the context of their gene expression, structure, and interactions with neighboring musculoskeletal tissues. We highlight the similarities with tendon development in higher vertebrates, showing that the craniofacial tendons and ligaments in zebrafish morphologically, molecularly, and structurally resemble mammalian tendons and ligaments from embryonic to adult stages. We detail methods for fluorescent in situ hybridization and immunohistochemistry as an assay to examine morphological changes in the zebrafish musculoskeleton. Staining assays such as these could provide the foundation for screen-based approaches to identify new regulators of tendon development, morphogenesis, and repair. These discoveries would provide new targets and pathways to study in the context of regenerative medicine-based approaches to improve tendon healing. PMID:28129848

  4. An Overview of the Management of Flexor Tendon Injuries

    PubMed Central

    Griffin, M; Hindocha, S; Jordan, D; Saleh, M; Khan, W

    2012-01-01

    Flexor tendon injuries still remain a challenging condition to manage to ensure optimal outcome for the patient. Since the first flexor tendon repair was described by Kirchmayr in 1917, several approaches to flexor tendon injury have enabled successful repairs rates of 70-90%. Primary surgical repair results in better functional outcome compared to secondary repair or tendon graft surgery. Flexor tendon injury repair has been extensively researched and the literature demonstrates successful repair requires minimal gapping at the repair site or interference with tendon vascularity, secure suture knots, smooth junction of tendon end and having sufficient strength for healing. However, the exact surgical approach to achieve success being currently used among surgeons is still controversial. Therefore, this review aims to discuss the results of studies demonstrating the current knowledge regarding the optimal approach for flexor tendon repair. Post-operative rehabilitation for flexor tendon surgery is another area, which has caused extensive debate in hand surgery. The trend to more active mobilisation protocols seems to be favoured but further study in this area is needed to find the protocol, which achieves function and gliding but avoids rupture of the tendons. Lastly despite success following surgery complications commonly still occur post surgery, including adhesion formation, tendon rupture and stiffness of the joints. Therefore, this review aims to discuss the appropriate management of these difficulties post surgery. New techniques in management of flexor tendon will also be discussed including external laser devices, addition of growth factors and cytokines. PMID:22431948

  5. 21 CFR 888.3025 - Passive tendon prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Passive tendon prosthesis. 888.3025 Section 888...) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3025 Passive tendon prosthesis. (a) Identification. A passive tendon prosthesis is a device intended to be implanted made of silicon elastomer or a...

  6. 21 CFR 888.3025 - Passive tendon prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Passive tendon prosthesis. 888.3025 Section 888...) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3025 Passive tendon prosthesis. (a) Identification. A passive tendon prosthesis is a device intended to be implanted made of silicon elastomer or a...

  7. [Results of flexor tendon sutures of the fingers with 2-strand (40 tendons) and 4-strand (64 tendons) core sutures].

    PubMed

    Winkel, R; Kalbhenn, O; Hoffmann, R

    2012-06-01

    This retrospective examination compares the results of finger flexor tendon sutures with 2 strands and 4 strands. It was checked, whether and how 2 more strands influenced the rupture rate, the movement of the finger and the contentment of the patients. From 1996 to 2000 for the core suture of the flexor tendon of fingers we used 2 strands. 35 patients with 40 tendon sutures of 73 patients were examined. From 2001 to 2005 we used for the core suture 2 loop threads. 53 patients with 64 tendon sutures from a total of 111 patients were examined. At least 12 months had passed between operation and the examination. The rupture rate and the range of movement of each finger joint and the total mobility of the affected fingers were evaluated. Each case was compared to the uninjured opposite hand. The functional result was judged according to the score of Buck-Gramcko. The patient's contentment was recorded by the DASH (disability of arm, shoulder and hand) score. Effects of gender, age, accompanying injuries, zone of the injury and their influence on the results were analysed. The Buck-Gramcko score showed in the 2-strand group a distribution from summarised 70% "excellent" and "good" and 30% "fair" and "poor". In the 4-strand-group the relation was 93.7% "excellent" and "good", 6.3% "fair", one "poor". In the 2-strand group 2/40 (5%) of the tendon sutures ruptured, in the 4-strand group 1/64 (1.6%) ruptured. The average DASH value in the 2-strands-group was 16.6/100, in the 4-strands-group 18.1/100 when 0 is the best possible result and 100 the worst. The patient judgement in the 2-strand group was summarised to 70% for "excellent" and "good" and 30% "fair" and "poor". In the 4-strand group the patient's judgment was summarised in 75% "excellent" and "good" and in 25% "fair". The results of flexor tendon sutures with 4-strand core sutures have been superior to the results with 2-strand core suture according to range of motion of the fingers (P <0.005). © Georg Thieme

  8. A Patient-Specific Foot Model for the Estimate of Ankle Joint Forces in Patients with Juvenile Idiopathic Arthritis.

    PubMed

    Prinold, Joe A I; Mazzà, Claudia; Di Marco, Roberto; Hannah, Iain; Malattia, Clara; Magni-Manzoni, Silvia; Petrarca, Maurizio; Ronchetti, Anna B; Tanturri de Horatio, Laura; van Dijkhuizen, E H Pieter; Wesarg, Stefan; Viceconti, Marco

    2016-01-01

    Juvenile idiopathic arthritis (JIA) is the leading cause of childhood disability from a musculoskeletal disorder. It generally affects large joints such as the knee and the ankle, often causing structural damage. Different factors contribute to the damage onset, including altered joint loading and other mechanical factors, associated with pain and inflammation. The prediction of patients' joint loading can hence be a valuable tool in understanding the disease mechanisms involved in structural damage progression. A number of lower-limb musculoskeletal models have been proposed to analyse the hip and knee joints, but juvenile models of the foot are still lacking. This paper presents a modelling pipeline that allows the creation of juvenile patient-specific models starting from lower limb kinematics and foot and ankle MRI data. This pipeline has been applied to data from three children with JIA and the importance of patient-specific parameters and modelling assumptions has been tested in a sensitivity analysis focused on the variation of the joint reaction forces. This analysis highlighted the criticality of patient-specific definition of the ankle joint axes and location of the Achilles tendon insertions. Patient-specific detection of the Tibialis Anterior, Tibialis Posterior, and Peroneus Longus origins and insertions were also shown to be important.

  9. Biomechanical Cadaveric Evaluation of Partial Acute Peroneal Tendon Tears.

    PubMed

    Wagner, Emilio; Wagner, Pablo; Ortiz, Cristian; Radkievich, Ruben; Palma, Felipe; Guzmán-Venegas, Rodrigo

    2018-06-01

    No clear guideline or solid evidence exists for peroneal tendon tears to determine when to repair, resect, or perform a tenodesis on the damaged tendon. The objective of this study was to analyze the mechanical behavior of cadaveric peroneal tendons artificially damaged and tested in a cyclic and failure mode. The hypothesis was that no failure would be observed in the cyclic phase. Eight cadaveric long leg specimens were tested on a specially designed frame. A longitudinal full thickness tendon defect was created, 3 cm in length, behind the tip of the fibula, compromising 66% of the visible width of the peroneal tendons. Cyclic testing was initially performed between 50 and 200 N, followed by a load-to-failure test. Tendon elongation and load to rupture were measured. No tendon failed or lengthened during cyclic testing. The mean load to failure for peroneus brevis was 416 N (95% confidence interval, 351-481 N) and for the peroneus longus was 723 N (95% confidence interval, 578-868 N). All failures were at the level of the defect created. In a cadaveric model of peroneal tendon tears, 33% of remaining peroneal tendon could resist high tensile forces, above the physiologic threshold. Some peroneal tendon tears can be treated conservatively without risking spontaneous ruptures. When surgically treating a symptomatic peroneal tendon tear, increased efforts may be undertaken to repair tears previously considered irreparable.

  10. Augmented Repair of an Achilles Tendon Rupture Using the Flexor Digitorum Lateralis Tendon in a Toy Poodle.

    PubMed

    Katayama, Masaaki

    2016-11-01

    To report appositional augmentation of Achilles tendon rupture in a toy breed dog with an intact flexor digitorum lateralis (FDL) muscle tendon. Clinical case report. Two-year-old spayed female Toy Poodle with Achilles tendon rupture. The Achilles tendon was accidentally ruptured by hair clippers during grooming. The dog demonstrated a plantigrade stance without digital flexion of the right hind limb. The ruptured gastrocnemius and superficial digital flexor tendons were sutured to their respective cut ends using a simple locking loop pattern under a surgical microscope. The repair site was appositionally augmented by the caudally retracted intact FDL. An aluminum splint was applied on the plantar aspect to immobilize the tarsal joint for the first 2 weeks, after which a soft bandage was applied for another 2 weeks. At the 7 month follow-up no lameness was detected during walking and no complications associated with decreased FDL function such as digital contracture were observed. The range of motion of the tarsal joint had improved and could be flexed to ∼60° and extended fully. Use of the FDL is feasible for augmenting Achilles tendon repair in toy breed dogs. © Copyright 2016 by The American College of Veterinary Surgeons.

  11. Bilateral Patellar Tendon Rupture.

    PubMed

    Kamienski, Mary

    The knee is the most complex and largest joint in the body. Injuries to any part of this joint affect the entire body. There are multiple injuries that can occur to the knee, with the most common being ligament and meniscus tears. A not-so-common injury to the knee is a patellar tendon rupture. A bilateral patellar tendon rupture is extremely rare. A case study of a 43-year-old man who sustained a bilateral patellar tendon rupture while playing softball is used to present this devastating injury. This discussion includes the incidence and diagnosis of the tear, surgical repair, as well as a description of the comprehensive rehabilitation process necessary to allow the patient to return to normal physical activity. Risks and complications of this surgery and the expected outcomes are also presented.

  12. Anterior deltoid deficiency in reverse total shoulder replacement: a biomechanical study with cadavers.

    PubMed

    Gulotta, L V; Choi, D; Marinello, P; Wright, T; Cordasco, F A; Craig, E V; Warren, R F

    2012-12-01

    Reverse total shoulder replacement (RTSR) depends on adequate deltoid function for a successful outcome. However, the anterior deltoid and/or axillary nerve may be damaged due to prior procedures or injury. The purpose of this study was to determine the compensatory muscle forces required for scapular plane elevation following RTSR when the anterior deltoid is deficient. The soft tissues were removed from six cadaver shoulders, except for tendon attachments. After implantation of the RTSR, the shoulders were mounted on a custom-made shoulder simulator to determine the mean force in each muscle required to achieve 30° and 60° of scapular plane elevation. Two conditions were tested: 1) Control with an absent supraspinatus and infraspinatus; and 2) Control with anterior deltoid deficiency. Anterior deltoid deficiency resulted in a mean increase of 195% in subscapularis force at 30° when compared with the control (p = 0.02). At 60°, the subscapularis force increased a mean of 82% (p < 0.001) and the middle deltoid force increased a mean of 26% (p = 0.04). Scapular plane elevation may still be possible following an RTSR in the setting of anterior deltoid deficiency. When the anterior deltoid is deficient, there is a compensatory increase in the force required by the subscapularis and middle deltoid. Attempts to preserve the subscapularis, if present, might maximise post-operative function.

  13. Robot Arm with Tendon Connector Plate and Linear Actuator

    NASA Technical Reports Server (NTRS)

    Bridgwater, Lyndon (Inventor); Millerman, Alexander (Inventor); Ihrke, Chris A. (Inventor); Diftler, Myron A. (Inventor); Nguyen, Vienny (Inventor)

    2014-01-01

    A robotic system includes a tendon-driven end effector, a linear actuator, a flexible tendon, and a plate assembly. The linear actuator assembly has a servo motor and a drive mechanism, the latter of which translates linearly with respect to a drive axis of the servo motor in response to output torque from the servo motor. The tendon connects to the end effector and drive mechanism. The plate assembly is disposed between the linear actuator assembly and the tendon-driven end effector and includes first and second plates. The first plate has a first side that defines a boss with a center opening. The second plate defines an accurate through-slot having tendon guide channels. The first plate defines a through passage for the tendon between the center opening and a second side of the first plate. A looped end of the flexible tendon is received within the tendon guide channels.

  14. [Flexor tendon repair: a short story].

    PubMed

    Moutet, F; Corcella, D; Forli, A; Mesquida, V

    2014-12-01

    This short story of flexor tendon repair aims to illustrate hesitations and wanderings of this surgery. Obviously tendon repair was very early considered, but it developed and diffused rather lately. It became a routine practice only in 20th century. This was due on the one hand, in Occident, to the Galen's dogmatic interdiction, on the other hand, to the repair difficulties of this paradoxical structure. Actually tendon is made of fibroblasts and collagen (sticky substances), and then its only goal is to move. According to this necessity, whatever the used techniques are, gliding is the final purpose. Technical evolutions are illustrated by historical contributions to flexor tendon surgery of several "giants" of hand surgery. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  15. Effect of Tendon Stem Cells in Chitosan/β-Glycerophosphate/Collagen Hydrogel on Achilles Tendon Healing in a Rat Model.

    PubMed

    Yang, Zhijin; Cao, Honghui; Gao, Shang; Yang, Mingyu; Lyu, Jingtong; Tang, Kanglai

    2017-09-27

    BACKGROUND The aim of this study was to determine whether the local application of tendon stem cells (TSCs) with chitosan/β-glycerophosphate/collagen(C/GP/Co) hydrogel promotes healing after an acute Achilles tendon injury in a rat model. MATERIAL AND METHODS Ninety-six Sprague-Dawley (SD) rats were used to make an Achilles tendon defect model, then the animals were randomly divided into 4 groups consisting of 8 rats each: control group, hydrogel group, TSCs group, and TSCs with hydrogel group. At 2, 4, and 6 weeks after treatment, tendon samples were harvested, and the quality of tendon repair was evaluated based on histology, immunohistochemistry, and biomechanical properties. RESULTS Combining TSCs with C/GP/Co hydrogel significantly enhances tendon healing compared with the control, hydrogel, and TSCs groups. The improved healing was indicated by the improvement in histological and immunohistochemistry outcomes and the increase in the biomechanical properties of the regenerated tissue at both 4 and 6 weeks post-injury. CONCLUSIONS This study demonstrates that the transplantation of TSCs combined with C/GP/Co hydrogel significantly improved the histological, immunohistochemistry, and biomechanical outcomes of the regenerated tissue at 4 and 6 weeks after implantation. TSCs with C/GP/Co hydrogel is a potentially effective treatment for tendon injury.

  16. New Developments Are Improving Flexor Tendon Repair.

    PubMed

    Tang, Jin Bo

    2018-06-01

    New developments in primary tendon repair in recent decades include stronger core tendon repair techniques, judicious and adequate venting of critical pulleys, followed by a combination of passive and active digital flexion and extension. During repair, core sutures over the tendon should have sufficient suture purchase (no shorter than 0.7 to 1 cm) in each tendon end and must be sufficiently tensioned to resist loosening and gap formation between tendon ends. Slight or even modest bulkiness in the tendon substance at the repair site is not harmful, although marked bulkiness should always be avoided. To expose the tendon ends and reduce restriction to tendon gliding, the longest annular pulley in the fingers (i.e., the A2 pulley) can be vented partially with an incision over its distal or proximal sheath no longer than 1.5 to 2 cm; the annular pulley over the middle phalanx (i.e., the A4 pulley) can be vented entirely. Surgeons have not observed adverse effects on hand function after judicious and limited venting. The digital extension-flexion test to check the quality of the repair during surgery has become increasingly routine. A wide-awake surgical setting allows patient to actively move the digits. After surgery, surgeons and therapists protect patients with a short splint and flexible wrist positioning, and are now moving toward out-of-splint freer early active motion. Improved outcomes have been reported over the past decade with minimal or no rupture during postoperative active motion, along with lower rates of tenolysis.

  17. Rotator cuff tendon connections with the rotator cable.

    PubMed

    Rahu, Madis; Kolts, Ivo; Põldoja, Elle; Kask, Kristo

    2017-07-01

    The literature currently contains no descriptions of the rotator cuff tendons, which also describes in relation to the presence and characteristics of the rotator cable (anatomically known as the ligamentum semicirculare humeri). The aim of the current study was to elucidate the detailed anatomy of the rotator cuff tendons in association with the rotator cable. Anatomic dissection was performed on 21 fresh-frozen shoulder specimens with an average age of 68 years. The rotator cuff tendons were dissected from each other and from the glenohumeral joint capsule, and the superior glenohumeral, coracohumeral, coracoglenoidal and semicircular (rotator cable) ligaments were dissected. Dissection was performed layer by layer and from the bursal side to the joint. All ligaments and tendons were dissected in fine detail. The rotator cable was found in all specimens. It was tightly connected to the supraspinatus (SSP) tendon, which was partly covered by the infraspinatus (ISP) tendon. The posterior insertion area of the rotator cable was located in the region between the middle and inferior facets of the greater tubercle of the humerus insertion areas for the teres minor (TM), and ISP tendons were also present and fibres from the SSP extended through the rotator cable to those areas. The connection between the rotator cable and rotator cuff tendons is tight and confirms the suspension bridge theory for rotator cuff tears in most areas between the SSP tendons and rotator cable. In its posterior insertion area, the rotator cable is a connecting structure between the TM, ISP and SSP tendons. These findings might explain why some patients with relatively large rotator cuff tears can maintain seamless shoulder function.

  18. Treatment of the neglected Achilles tendon rupture.

    PubMed

    Bevilacqua, Nicholas J

    2012-04-01

    Achilles tendon ruptures are best managed acutely. Neglected Achilles tendon ruptures are debilitating injuries and the increased complexity of the situation must be appreciated. Surgical management is recommended, and only in the poorest surgical candidate is conservative treatment entertained. Numerous treatment algorithms and surgical techniques have been described. A V-Y advancement flap and flexor halluces longus tendon transfer have been found to be reliable and achieve good clinical outcomes for defects ranging from 2 cm to 8 cm. This article focuses on the treatment options for the neglected Achilles tendon rupture. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Relationship between tendon stiffness and failure: a metaanalysis

    PubMed Central

    LaCroix, Andrew S.; Duenwald-Kuehl, Sarah E.; Lakes, Roderic S.

    2013-01-01

    Tendon is a highly specialized, hierarchical tissue designed to transfer forces from muscle to bone; complex viscoelastic and anisotropic behaviors have been extensively characterized for specific subsets of tendons. Reported mechanical data consistently show a pseudoelastic, stress-vs.-strain behavior with a linear slope after an initial toe region. Many studies report a linear, elastic modulus, or Young's modulus (hereafter called elastic modulus) and ultimate stress for their tendon specimens. Individually, these studies are unable to provide a broader, interstudy understanding of tendon mechanical behavior. Herein we present a metaanalysis of pooled mechanical data from a representative sample of tendons from different species. These data include healthy tendons and those altered by injury and healing, genetic modification, allograft preparation, mechanical environment, and age. Fifty studies were selected and analyzed. Despite a wide range of mechanical properties between and within species, elastic modulus and ultimate stress are highly correlated (R2 = 0.785), suggesting that tendon failure is highly strain-dependent. Furthermore, this relationship was observed to be predictable over controlled ranges of elastic moduli, as would be typical of any individual species. With the knowledge gained through this metaanalysis, noninvasive tools could measure elastic modulus in vivo and reasonably predict ultimate stress (or structural compromise) for diseased or injured tendon. PMID:23599401

  20. The use of Achilles tendon allograft for latissimus dorsi tendon reconstruction: a minimally invasive technique.

    PubMed

    Sabzevari, Soheil; Chao, Tom; Kalawadia, Jay; Lin, Albert

    2018-01-01

    Treatment of subacute, retracted latissimus dorsi and teres major tendon ruptures in young overhead athletes is challenging. This case report describes management of a subacute retracted latissimus dorsi and teres major rupture with Achilles tendon allograft reconstruction using a two-incision minimally invasive technique. Level of evidence V.

  1. [Conservative functional treatment of Achilles tendon ruptures].

    PubMed

    Hüfner, T; Gaulke, R; Imrecke, J; Krettek, C; Stübig, T

    2010-09-01

    The conservative functional treatment of Achilles tendon ruptures has developed further over the last 20 years and is basically possible for 60-80% of patients. The treatment leads to success if the indications obtained by dynamic sonography are correctly interpreted (adaptation of the tendon ends up to 20 degrees plantar flexion), if the patient presents sufficient compliance and the physiotherapy is increasingly intensified depending on tendon healing. Modern ortheses allow an increased equinus position and therefore improved protection of the healing tendon. If these factors are present a relatively low re-rupture rate of only 7% can be achieved. The decisive advantage of conservative functional therapy is the avoidance of specific operative risks, such as infection and injury to the sural nerve. After removal of the orthesis the tendon should continue to be modeled using shoe insoles and raised heels.

  2. Position Control of Tendon-Driven Fingers

    NASA Technical Reports Server (NTRS)

    Abdallah, Muhammad E.; Platt, Robert, Jr.; Hargrave, B.; Pementer, Frank

    2011-01-01

    Conventionally, tendon-driven manipulators implement some force control scheme based on tension feedback. This feedback allows the system to ensure that the tendons are maintained taut with proper levels of tensioning at all times. Occasionally, whether it is due to the lack of tension feedback or the inability to implement sufficiently high stiffnesses, a position control scheme is needed. This work compares three position controllers for tendon-driven manipulators. A new controller is introduced that achieves the best overall performance with regards to speed, accuracy, and transient behavior. To compensate for the lack of tension feedback, the controller nominally maintains the internal tension on the tendons by implementing a two-tier architecture with a range-space constraint. These control laws are validated experimentally on the Robonaut-2 humanoid hand. I

  3. Is the chronic painful tendinosis tendon a strong tendon?: a case study involving an Olympic weightlifter with chronic painful Jumper's knee.

    PubMed

    Gisslén, Karl; Ohberg, Lars; Alfredson, Håkan

    2006-09-01

    The chronic painful tendinosis tendon is generally considered a degenerated and weak tendon. However, this has not been scientifically verified, and is to be considered a hypothesis. We present here a case study involving a high-level Olympic weightlifter with chronic painful patellar tendinosis who started heavy-weight training very early after successful treatment with sclerosing injections. A 25-year-old super heavy-weight (+105 kg) Olympic weightlifter with 9 months duration of severe pain (prohibiting full training) in the proximal patellar tendon, where ultrasound and Doppler showed a widened tendon with structural changes and neovascularisation, was given one treatment with ultrasound and Doppler-guided injections of the sclerosing agent polidocanol. The injections targeted the neovessels posterior to the tendon. The patient was pain-free after the treatment, and already after 2-weeks he started with heavy-weight training (240 kg in deep squats) to try to qualify for the Olympics. Additional very heavy training on training camps, most often without having any discomfort or pain in the patellar tendon, resulted in Swedish records and ninth place at the European Championships 17 weeks after the treatment. Despite beating the national records, he did not qualify for the Olympics. Ultrasound and Doppler follow-ups have shown only a few remaining neovessels, and little structural tendon changes. This case questions previous theories about the weak tendinosis tendon, and stresses the importance of studies evaluating tendon strength.

  4. Uncovering the cellular and molecular changes in tendon stem/progenitor cells attributed to tendon aging and degeneration.

    PubMed

    Kohler, Julia; Popov, Cvetan; Klotz, Barbara; Alberton, Paolo; Prall, Wolf Christian; Haasters, Florian; Müller-Deubert, Sigrid; Ebert, Regina; Klein-Hitpass, Ludger; Jakob, Franz; Schieker, Matthias; Docheva, Denitsa

    2013-12-01

    Although the link between altered stem cell properties and tissue aging has been recognized, the molecular and cellular processes of tendon aging have not been elucidated. As tendons contain stem/progenitor cells (TSPC), we investigated whether the molecular and cellular attributes of TSPC alter during tendon aging and degeneration. Comparing TSPC derived from young/healthy (Y-TSPC) and aged/degenerated human Achilles tendon biopsies (A-TSPC), we observed that A-TSPC exhibit a profound self-renewal and clonogenic deficits, while their multipotency was still retained. Senescence analysis showed a premature entry into senescence of the A-TSPC, a finding accompanied by an upregulation of p16(INK4A). To identify age-related molecular factors, we performed microarray and gene ontology analyses. These analyses revealed an intriguing transcriptomal shift in A-TSPC, where the most differentially expressed probesets encode for genes regulating cell adhesion, migration, and actin cytoskeleton. Time-lapse analysis showed that A-TSPC exhibit decelerated motion and delayed wound closure concomitant to a higher actin stress fiber content and a slower turnover of actin filaments. Lastly, based on the expression analyses of microarray candidates, we suggest that dysregulated cell-matrix interactions and the ROCK kinase pathway might be key players in TSPC aging. Taken together, we propose that during tendon aging and degeneration, the TSPC pool is becoming exhausted in terms of size and functional fitness. Thus, our study provides the first fundamental basis for further exploration into the molecular mechanisms behind tendon aging and degeneration as well as for the selection of novel tendon-specific therapeutical targets. © 2013 The Authors. Aging Cell published by the Anatomical Society and John Wiley & Sons Ltd.

  5. Anterior Cruciate Ligament Reconstruction in a Rabbit Model Using Silk-Collagen Scaffold and Comparison with Autograft

    PubMed Central

    Bi, Fanggang; Shi, Zhongli; Liu, An; Guo, Peng; Yan, Shigui

    2015-01-01

    The objective of the present study was to perform an in vivo assessment of a novel silk-collagen scaffold for anterior cruciate ligament (ACL) reconstruction. First, a silk-collagen scaffold was fabricated by combining sericin-extracted knitted silk fibroin mesh and type I collagen to mimic the components of the ligament. Scaffolds were electron-beam sterilized and rolled up to replace the ACL in 20 rabbits in the scaffold group, and autologous semitendinosus tendons were used to reconstruct the ACL in the autograft control group. At 4 and 16 weeks after surgery, grafts were retrieved and analyzed for neoligament regeneration and tendon-bone healing. To evaluate neoligament regeneration, H&E and immunohistochemical staining was performed, and to assess tendon-bone healing, micro-CT, biomechanical test, H&E and Russell-Movat pentachrome staining were performed. Cell infiltration increased over time in the scaffold group, and abundant fibroblast-like cells were found in the core of the scaffold graft at 16 weeks postoperatively. Tenascin-C was strongly positive in newly regenerated tissue at 4 and 16 weeks postoperatively in the scaffold group, similar to observations in the autograft group. Compared with the autograft group, tendon-bone healing was better in the scaffold group with trabecular bone growth into the scaffold. The results indicate that the silk-collagen scaffold has considerable potential for clinical application. PMID:25938408

  6. [Tendinosis and ruptures of the Achilles tendon].

    PubMed

    Amlang, M H; Zwipp, H

    2012-02-01

    Tendinosis of the Achilles tendon is a degenerative-reparative structural change of the tendon with microdefects, increases in cross-section due to cicatricial tendon regeneration, neoangiogenesis and reduction of elasticity. The previously used term tendinitis is only rarely used for the chronic form since signs of inflammation such as redness and hyperthermia or elevated levels of inflammatory parameters on laboratory testing are generally absent. Duplex sonography with visualization of the neovascularization has become a valuable supplement not only for diagnostics but also for therapy planning. The classic, conservative therapy for painful tendinosis consists of oral anti-inflammatory drugs, pain-adapted load reduction, raising the heel, stretching the calf musculature, and various physiotherapeutic interventions. When conservative treatment over a period of 4 - 6 months fails to produce any or non-adequate pain relief, an indication for surgical treatment should be considered. In the therapy for fresh ruptures of the Achilles tendon further developments in minimally invasive techniques have led to a worldwide paradigm change over the past 10 years. The decisive advantage of minimally invasive surgical techniques is the lower risk of wound infection as compared to the sutures of the open technique. When compared with conservative functional therapy the minimally invasive repair has the advantage of being less dependent on the compliance of the patient since, in the early phase of tendon healing the suture prevents a separation of the tendon ends upon controlled movements. However, not every patient with a ruptured Achilles tendon should be treated with a minimally invasive repair. Open tendon reconstruction and functional conservative therapy are still justified when the correct indication is given. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Cell phenotypic variation in normal and damaged tendons

    PubMed Central

    Clegg, Peter D; Strassburg, Sandra; Smith, Roger K

    2007-01-01

    Injuries to tendons are common in both human athletes as well as in animals, such as the horse, which are used for competitive purposes. Furthermore, such injuries are also increasing in prevalence in the ageing, sedentary population. Tendon diseases often respond poorly to treatment and require lengthy periods of rehabilitation. The tendon has a unique extracellular matrix, which has developed to withstand the mechanical demands of such tensile-load bearing structures. Following injury, any repair process is inadequate and results in tissue that is distinct from original tendon tissue. There is growing evidence for the key role of the tendon cell (tenocyte) in both the normal physiological homeostasis and regulation of the tendon matrix and the pathological derangements that occur in disease. In particular, the tenocyte is considered to have a major role in effecting the subclinical matrix degeneration that is thought to occur prior to clinical disease, as well as in the severe degradative events that occur in the tendon at the onset of clinical disease. Furthermore, the tenocyte is likely to have a central role in the production of the biologically inadequate fibrocartilaginous repair tissue that develops subsequent to tendinopathy. Understanding the biology of the tenocyte is central to the development of appropriate interventions and drug therapies that will either prevent the onset of disease, or lead to more rapid and appropriate repair of injured tendon. Central to this is a full understanding of the proteolytic response in the tendon in disease by such enzymes as metalloproteinases, as well as the control of the inappropriate fibrocartilaginous differentiation. Finally, it is important that we understand the role of both intrinsic and extrinsic cellular elements in the repair process in the tendon subsequent to injury. PMID:17696903

  8. Tendon rupture associated with excessive smartphone gaming.

    PubMed

    Gilman, Luke; Cage, Dori N; Horn, Adam; Bishop, Frank; Klam, Warren P; Doan, Andrew P

    2015-06-01

    Excessive use of smartphones has been associated with injuries. A 29-year-old, right hand-dominant man presented with chronic left thumb pain and loss of active motion from playing a Match-3 puzzle video game on his smartphone all day for 6 to 8 weeks. On physical examination, the left extensor pollicis longus tendon was not palpable, and no tendon motion was noted with wrist tenodesis. The thumb metacarpophalangeal range of motion was 10° to 80°, and thumb interphalangeal range of motion was 30° to 70°. The clinical diagnosis was rupture of the left extensor pollicis longus tendon. The patient subsequently underwent an extensor indicis proprius (1 of 2 tendons that extend the index finger) to extensor pollicis longus tendon transfer. During surgery, rupture of the extensor pollicis longus tendon was seen between the metacarpophalangeal and wrist joints. The potential for video games to reduce pain perception raises clinical and social considerations about excessive use, abuse, and addiction. Future research should consider whether pain reduction is a reason some individuals play video games excessively, manifest addiction, or sustain injuries associated with video gaming.

  9. Return to Sports and Subsequent Injury Rates After Revision Anterior Cruciate Ligament Reconstruction With Patellar Tendon Autograft.

    PubMed

    Shelbourne, K Donald; Benner, Rodney W; Gray, Tinker

    2014-06-01

    The return-to-sport and reinjury rates are not well defined after revision anterior cruciate ligament (ACL) reconstruction. School-age athletes would have a higher rate of return to sports and reinjury to either knee after revision ACL surgery compared with college or recreational athletes. Cohort study; Level of evidence, 2. Patients were prospectively studied after revision ACL reconstruction with bone-patellar tendon-bone (BPTB) autograft. Participants were grouped by competitive sport levels of school age (mean age, 16.6 ± 0.9 years; n = 84), college (19.6 ± 1.2 years; n = 58), or recreational adult (27.6 ± 4.1 years; n = 117). An activity survey was used to determine the specific sport and sport level patients participated in before and after surgery. The International Knee Documentation Committee (IKDC) knee survey and Cincinnati Knee Rating System (CKRS) survey responses were also obtained. The rate of return to the same sport at the same level was 62 of 84 school-age athletes (74%), 43 of 58 college athletes (74%), and 73 of 117 recreational athletes (62%) (P = .1065). The number of patients who had a subsequent ACL graft tear rate after revision surgery was 2 of 84 (2.3%) in the high school group, 3 of 58 (5.1%) in the college group, and 4 of 117 (3.4%) in the recreational group (P = .6706). The number of patients who had a subsequent ACL tear in the contralateral knee was 1 of 84 (1.1%) in the school-age group, 1 of 58 (1.7%) in the college group, and 2 of 117 (1.7%) in the recreational group (P = .9501). At 2 years postoperatively, the mean IKDC subjective total score was 86.1 ± 11.7 points and the mean CKRS total score was 89.7 ± 11.1 points. Revision ACL reconstruction with BPTB autograft and perioperative rehabilitation allowed high school and college athletes to return to sports at the preinjury level at a rate of 74%; the return rate for recreational-level adults was 62%. Reinjury rates in the first 5 years after revision surgery ranged from 2

  10. Stem Cell Applications in Tendon Disorders: A Clinical Perspective

    PubMed Central

    Young, Mark

    2012-01-01

    Tendon injuries are a common cause of morbidity and a significant health burden on society. Tendons are structural tissues connecting muscle to bone and are prone to tearing and tendinopathy, an overuse or degenerative condition that is characterized by failed healing and cellular depletion. Current treatments, for tendon tear are conservative, surgical repair or surgical scaffold reconstruction. Tendinopathy is treated by exercises, injection therapies, shock wave treatments or surgical tendon debridement. However, tendons usually heal with fibrosis and scar tissue, which has suboptimal tensile strength and is prone to reinjury, resulting in lifestyle changes with activity restriction. Preclinical studies show that cell therapies have the potential to regenerate rather than repair tendon tissue, a process termed tenogenesis. A number of different cell lines, with varying degrees of differentiation, have being evaluated including stem cells, tendon derived cells and dermal fibroblasts. Even though cellular therapies offer some potential in treating tendon disorders, there have been few published clinical trials to determine the ideal cell source, the number of cells to administer, or the optimal bioscaffold for clinical use. PMID:22448174

  11. Force Model for Control of Tendon Driven Hands

    NASA Technical Reports Server (NTRS)

    Pena, Edward; Thompson, David E.

    1997-01-01

    Knowing the tendon forces generated for a given task such as grasping via a model, an artificial hand can be controlled. A two-dimensional force model for the index finger was developed. This system is assumed to be in static equilibrium, therefore, the equations of equilibrium were applied at each joint. Constraint equations describing the tendon branch connectivity were used. Gaussian elimination was used to solve for the unknowns of the Linear system. Results from initial work on estimating tendon forces in post-operative hands during active motion therapy were discussed. The results are important for understanding the effects of hand position on tendon tension, elastic effects on tendon tension, and overall functional anatomy of the hand.

  12. The role of animal models in tendon research

    PubMed Central

    Hast, M. W.; Zuskov, A.; Soslowsky, L. J.

    2014-01-01

    Tendinopathy is a debilitating musculoskeletal condition which can cause significant pain and lead to complete rupture of the tendon, which often requires surgical repair. Due in part to the large spectrum of tendon pathologies, these disorders continue to be a clinical challenge. Animal models are often used in this field of research as they offer an attractive framework to examine the cascade of processes that occur throughout both tendon pathology and repair. This review discusses the structural, mechanical, and biological changes that occur throughout tendon pathology in animal models, as well as strategies for the improvement of tendon healing. Cite this article: Bone Joint Res 2014;3:193–202. PMID:24958818

  13. The Achilles tendon: fundamental properties and mechanisms governing healing

    PubMed Central

    Freedman, Benjamin R.; Gordon, Joshua A.; Soslowsky, Louis J.

    2014-01-01

    Summary This review highlights recent research on Achilles tendon healing, and comments on the current clinical controversy surrounding the diagnosis and treatment of injury. The processes of Achilles tendon healing, as demonstrated through changes in its structure, composition, and biomechanics, are reviewed. Finally, a review of tendon developmental biology and mechano transductive pathways is completed to recognize recent efforts to augment injured Achilles tendons, and to suggest potential future strategies for therapeutic intervention and functional tissue engineering. Despite an abundance of clinical evidence suggesting that current treatments and rehabilitation strategies for Achilles tendon ruptures are equivocal, significant questions remain to fully elucidate the basic science mechanisms governing Achilles tendon injury, healing, treatment, and rehabilitation. PMID:25332943

  14. Intravoxel incoherent motion (IVIM) imaging in human achilles tendon.

    PubMed

    Wengler, Kenneth; Fukuda, Takeshi; Tank, Dharmesh; Huang, Mingqian; Gould, Elaine S; Schweitzer, Mark E; He, Xiang

    2018-05-09

    Limited microcirculation has been implicated in Achilles tendinopathy and may affect healing and disease progression. Existing invasive and noninvasive approaches to evaluate tendon microcirculation lack sensitivity and spatial coverage. To develop a novel Achilles tendon intravoxel incoherent motion (IVIM) MRI protocol to overcome the limitations from low tendon T 2 /T 2 * value and low intratendinous blood volume and blood velocity to evaluate tendon microcirculation. Prospective. Sixteen healthy male participants (age 31.0 ± 2.1) were recruited. A stimulated echo readout-segmented echo planar imaging (ste-RS-EPI) IVIM sequence at 3.0T. The feasibility of the proposed ste-RS-EPI IVIM protocol combined with Achilles tendon magic angle effect was evaluated. The sensitivity of the protocol was assessed by an exercise-induced intratendinous hemodynamic response in healthy participants. The vascular origin of the observed IVIM signal was validated by varying the diffusion mixing time and echo time. Two-tailed t-tests were used to evaluate differences (P < 0.05 was considered significant). Consistent with known tendon hypovascularity, the midportion Achilles tendon at baseline showed significantly lower IVIM-derived perfusion fraction (f p ) (3.1 ± 0.9%) compared to the proximal and distal Achilles tendon (6.0 ± 1.8% and 6.1 ± 2.0%, respectively; P < 0.01). Similarly, the midportion Achilles tendon exhibited significantly lower baseline blood flow index (D*×f p ) (40.9 ± 19.2, 18.3 ± 5.3, and 32.0 ± 9.4 in proximal, midportion, and distal Achilles tendon, respectively; P < 0.01). Eccentric heel-raise exercise led to ∼2 times increase of Achilles tendon blood flow in healthy participants. Consistent with its vascular origin, the estimated f p demonstrated a high dependency to IVIM protocol parameters, while the T 1 /T 2 -corrected absolute intratendinous microvascular blood volume fraction (V b ) did not vary. Achilles tendon ste-RS-EPI IVIM noninvasively

  15. Tendon entheses of the human masticatory muscles.

    PubMed

    Hems, T; Tillmann, B

    2000-09-01

    Tendons attach to the limb skeleton via chondral-apophysary or periosteal-diaphysary entheses. It was the aim of the present study to investigate the tendon entheses of the temporal, the masseter, as well as the medial and lateral pterygoid muscles, considering the biomechanics and the mode of osteogenesis at the attachment sites. The origin and insertion zones of the four masticatory muscles were studied histologically and by polarization light microscopy in six halves of human heads. Contrary to the limb skeleton no causal relationship between the histological structure of the tendon entheses and the osteogenic mode of the bone areas involved was observed in the masticatory muscles that were studied. Based on the histological findings, a purely structural classification of the tendon attachments irrespective of the osteogenesis is therefore proposed that is applicable to the entire skeleton. It is possible to distinguish between tendon entheses inserting into periosteum, into bone or into fibrocartilage. Tendon attachments with periosteal insertion are found at the temporal plane, the retromolar triangle, zygomatic arch, lateral pterygoid plate, in the caudal zone of the pterygoid fovea of the neck of mandible as well as major portions of the ramus and angle of the mandible. The attachment zones in which collagen fibrils of tendons insert into the bone via the periosteum correspond in their structure to plane periosteal-diaphysary insertions into the diaphyses of long bones. Attachment zones to the bone are present at the inferior temporal line, the base of the coronoid process, the caudal surface of the zygomatic arch, the cranial zones of the pterygoid fovea of the neck of the mandible as well as at circumscribed areas of the ramus and angle of the mandible. In these zones the collagen fibers of the tendon insert immediately into the bone without any mediation of other tissues. The entheses resemble those of circumscribed periosteal-diaphysary attachments to

  16. Closing the gap on Achilles tendon rupture: A cadaveric study quantifying the tendon apposition achieved with commonly used immobilisation practices.

    PubMed

    Collins, Ruaraidh; Sudlow, Alexis; Loizou, Constantinos; Loveday, David T; Smith, George

    2018-04-01

    The relative benefits of surgical and conservative treatment of Achilles tendon rupture are widely debated. With modern conservative management protocols, the re-rupture risk appears to fall to one similar to surgical repair with negligible loss of function. Conservative management typically employs a period of time in an equinus cast with sequential ankle dorsiflexion in a functional orthosis. The optimal duration of immobilisation and rate of dorsiflexion is unknown. We aimed to quantify the change in Achilles tendon approximation achieved in common immobilisation techniques to assist the design of rehabilitation protocols. Twelve fresh-frozen cadaveric specimens had 2.5cm of Achilles tendon excised. The gap between the tendon ends were measured via windowed full equinus casts and compared with functional boots with successively removed heel wedges. The greatest tendon apposition was achieved with the equinus cast. Each wedge removed decreased the reapproximation by approximately 5mm. This paper supports the early use of maximal equinus casting in early management of acute Achilles tendon ruptures. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  17. Tendon allograft sterilized by peracetic acid/ethanol combined with gamma irradiation.

    PubMed

    Zhou, Mo; Zhang, Naili; Liu, Xiaoming; Li, Youchen; Zhang, Yumin; Wang, Xusheng; Li, Baoming; Li, Baoxing

    2014-07-01

    Research and clinical applications have demonstrated that the effects of tendon allografts are comparable to those of autografts when reconstructing injured tendons or ligaments, but allograft safety remains problematic. Sterilisation could eliminate or decrease the possibility of disease transmission, but current methods seldom achieve satisfactory sterilisation without affecting the mechanical properties of the tendon. Peracetic acid-ethanol in combination with low-dose gamma irradiation (PE-R) would inactivate potential deleterious microorganisms without affecting mechanical and biocompatible properties of tendon allograft. Controlled laboratory design. HIV, PPV, PRV and BVDV inactivation was evaluated. After verifying viral inactivation, the treated tendon allografts were characterised by optical microscopy, scanning electron microscopy and tensile testing, and the cytocompatibility was assessed with an MTT assay and by subcutaneous implantation. Effective and efficient inactivation of HIV, PPV, PRV and BVDV was observed. Histological structure and ultrastructure were unchanged in the treated tendon allograft, which also exhibited comparable biomechanical properties and good biocompatibility. The preliminary results confirmed our hypothesis and demonstrated that the PE-R tendon allograft has significant potential as an alternative to ligament/tendon reconstruction. Tendon allografts have been extensively used in ligament reconstruction and tendon repair. However, current sterilisation methods have various shortcomings, so PE-R has been proposed. This study suggests that PE-R tendon allograft has great potential as an alternative for ligament/tendon reconstruction. Sterilisation has been a great concern for tendon allografts. However, most sterilisation methods cannot inactivate viruses and bacteria without impairing the mechanical properties of the tendon allograft. Peracetic acid/ethanol with gamma irradiation can effectively inactivate viruses and bacteria

  18. Conservative management of partial extensor tendon lacerations greater than half the width of the tendon in manual workers.

    PubMed

    Al-Qattan, Mohammad M

    2015-04-01

    Conservative management (without suturing or splints) of partial extensor tendon lacerations greater than half the width of the tendon has not been previously investigated. In this prospective study, a total of 45 injured tendons (with lacerations involving 55%-90% of the width of the tendon) in 39 patients were treated conservatively. Injury zones I, III, and V of the fingers; and zones I and III of the thumb were excluded. Immediate non-resistive active mobilization was initiated and continued for 4 weeks, followed by resistive exercises. Patients were allowed to go back to work after 6 weeks. There were no cases of ruptures, triggering, infection, or complex regional pain syndrome. At final follow-up (8-9 months after injury), all patients obtained full range of motion with no extension lags. All patients were able to go back to normal duties. We conclude that early active motion without the use of splints or sutures in major extensor tendon lacerations in zones II, IV, VI-VIII of the fingers; and zones II, IV, and V of the thumb is safe.

  19. Is there still a place for Achilles tendon lengthening?

    PubMed

    Tagoe, Mark T; Reeves, Neil D; Bowling, Frank L

    2016-01-01

    Patients with diabetes and ankle equinus are at particularly high risk for forefoot ulceration because of the development of high forefoot pressures. Stiffness in the triceps surae muscles and tendons are thought to be largely responsible for equinus in patients with diabetes and underpins the surgical rationale for Achilles tendon lengthening (ATL) procedures to alleviate this deformity and reduce ulcer risk. The established/traditional surgical approach is the triple hemisection along the length of the Achilles tendon. Although the percutaneous approach has been successful in achieving increases in ankle dorsiflexion >30°, the tendon rupture risk has led to some surgeons looking at alternative approaches. The gastrocnemius aponeurosis may be considered as an alternative because of the Achilles tendon's poor blood supply. ATL procedures are a balance between achieving adequate tendon lengthening and minimizing tendon rupture risk during or after surgery. After ATL surgery, the first 7 days should involve reduced loading and protected range of motion to avoid rupture, after which gradual reintroduction to loading should be encouraged to increase tendon strength. In summary, there is a moderate level of evidence to support surgical intervention for ankle joint equinus in patients with diabetes and forefoot ulceration that is non-responsive to other conservative treatments. Areas of caution for ATL procedures include the risk for overcorrection, tendon rupture and the tendon's poor blood supply. Further prospective randomized control trials are required to confirm the benefits of ATL procedures over conservative care and the most optimal anatomical sites for surgical intervention. Copyright © 2016 John Wiley & Sons, Ltd.

  20. Achilles tendon reflex measuring system

    NASA Astrophysics Data System (ADS)

    Szebeszczyk, Janina; Straszecka, Joanna

    1995-06-01

    The examination of Achilles tendon reflex is widely used as a simple, noninvasive clinical test in diagnosis and pharmacological therapy monitoring in such diseases as: hypothyroidism, hyperthyroidism, diabetic neuropathy, the lower limbs obstructive angiopathies and intermittent claudication. Presented Achilles tendon reflect measuring system is based on the piezoresistive sensor connected with the cylinder-piston system. To determinate the moment of Achilles tendon stimulation a detecting circuit was used. The outputs of the measuring system are connected to the PC-based data acquisition board. Experimental results showed that the measurement accuracy and repeatability is good enough for diagnostics and therapy monitoring purposes. A user friendly, easy-to-operate measurement system fulfills all the requirements related to recording, presentation and storing of the patients' reflexograms.

  1. Effects of regular Tai Chi practice and jogging on neuromuscular reaction during lateral postural control in older people.

    PubMed

    Wang, Shao-Jun; Xu, Dong-Qing; Li, Jing-Xian

    2017-01-01

    This study examined the effects of regular Tai Chi practice and jogging on the neuromuscular activity of the trunk, hip, and ankle joint muscles of older people during lateral postural perturbation. A total of 42 older people participated in the study and formed the Tai Chi, jogging, and sedentary control groups. Electromyography signals were collected from the peroneus longus, anterior tibialis, gluteus medius, and erector spinae during unpredictable mediolateral perturbation. The Tai Chi group exhibited significantly faster latencies of the tibialis anterior and erector spinae than the control group. The jogging group showed a significantly shorter neuromuscular reaction time of the erector spinae than the control group. No significant difference was observed between the Tai Chi and jogging groups. Long-term regular Tai Chi practice enhanced the neuromuscular reaction of the erector spinae and tibialis anterior to lateral perturbation and will help timely posture correction when lateral postural distributions occur.

  2. The Degree of Knee Extension Does Not Affect Postoperative Stability or Subsequent Graft Tear Rate After Anterior Cruciate Ligament Reconstruction With Patellar Tendon Autograft.

    PubMed

    Benner, Rodney W; Shelbourne, K Donald; Gray, Tinker

    2016-04-01

    There is concern that high degrees of hyperextension may lead to an increase in graft laxity or graft failure after anterior cruciate ligament (ACL) reconstruction. Patients with a high degree of hyperextension will have a higher rate of graft tear/failure and lower subjective scores after surgery compared with patients with less knee extension. Cohort study, Level of evidence, 2. Of 2329 patients who underwent ACL reconstruction with patellar tendon autograft between 1998 and 2008, there were 625 patients who met the inclusion criteria of having primary ACL surgery, no bilateral ACL injuries, no existing osteoarthritis, and having either ≥6° of knee hyperextension before and after surgery (group A: n = 318; mean hyperextension, 8° ± 2° [range, 6°-15°]) or ≤3° of knee hyperextension before and after surgery (group B: n = 307; mean hyperextension, 0° ± 3° [range, 3° hyperextension to -4° short of 0° neutral]). KT-1000 arthrometer manual maximum difference between knees, range of motion measurements, and subjective follow-up with International Knee Documentation Committee (IKDC) and Cincinnati Knee Ratings Scale (CKRS) surveys were used to evaluate results. Subsequent graft tear related to specific injury within 5 years of surgery was recorded. Graft failure was defined as a KT-1000 manual maximum difference of >5 mm. Follow-up was obtained from 278 (87%) in group A and 275 (90%) in group B at a mean of 4.1 ± 1.1 years after surgery. The KT-1000 arthrometer manual maximum difference between knees was 2.0 ± 1.4 in group A and 2.1 ± 1.6 in group B (P = .701). Subsequent ACL graft tear/failure occurred in 22 patients (6.9%) in group A and 30 patients (9.8%) in group B (P = .246). Further subanalysis showed that the graft tear/failure rate was 6 of 81 (7.4%) for patients with ≥10° of hyperextension versus 16 of 237 (6.8%) for patients with 6° to 9° of hyperextension. There was no difference in IKDC or CKRS scores between groups after surgery (P

  3. Tendon basic science: Development, repair, regeneration, and healing.

    PubMed

    Andarawis-Puri, Nelly; Flatow, Evan L; Soslowsky, Louis J

    2015-06-01

    Tendinopathy and tendon rupture are common and disabling musculoskeletal conditions. Despite the prevalence of these injuries, a limited number of investigators are conducting fundamental, basic science studies focused on understanding processes governing tendinopathies and tendon healing. Development of effective therapeutics is hindered by the lack of fundamental guiding data on the biology of tendon development, signal transduction, mechanotransduction, and basic mechanisms underlying tendon pathogenesis and healing. To propel much needed progress, the New Frontiers in Tendon Research Conference, co-sponsored by NIAMS/NIH, the Orthopaedic Research Society, and the Icahn School of Medicine at Mount Sinai, was held to promote exchange of ideas between tendon researchers and basic science experts from outside the tendon field. Discussed research areas that are underdeveloped and represent major hurdles to the progress of the field will be presented in this review. To address some of these outstanding questions, conference discussions and breakout sessions focused on six topic areas (Cell Biology and Mechanics, Functional Extracellular Matrix, Development, Mechano-biology, Scarless Healing, and Mechanisms of Injury and Repair), which are reviewed in this special issue and briefly presented in this review. Review articles in this special issue summarize the progress in the field and identify essential new research directions. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  4. Torque Control of Underactuated Tendon-driven Robotic Fingers

    NASA Technical Reports Server (NTRS)

    Ihrke, Chris A. (Inventor); Wampler, Charles W. (Inventor); Abdallah, Muhammad E. (Inventor); Reiland, Matthew J. (Inventor); Diftler, Myron A. (Inventor); Bridgwater, Lyndon (Inventor); Platt, Robert (Inventor)

    2013-01-01

    A robotic system includes a robot having a total number of degrees of freedom (DOF) equal to at least n, an underactuated tendon-driven finger driven by n tendons and n DOF, the finger having at least two joints, being characterized by an asymmetrical joint radius in one embodiment. A controller is in communication with the robot, and controls actuation of the tendon-driven finger using force control. Operating the finger with force control on the tendons, rather than position control, eliminates the unconstrained slack-space that would have otherwise existed. The controller may utilize the asymmetrical joint radii to independently command joint torques. A method of controlling the finger includes commanding either independent or parameterized joint torques to the controller to actuate the fingers via force control on the tendons.

  5. Tendon biomechanics and mechanobiology--a minireview of basic concepts and recent advancements.

    PubMed

    Wang, James H-C; Guo, Qianping; Li, Bin

    2012-01-01

    Due to their unique hierarchical structure and composition, tendons possess characteristic biomechanical properties, including high mechanical strength and viscoelasticity, which enable them to carry and transmit mechanical loads (muscular forces) effectively. Tendons are also mechanoresponsive by adaptively changing their structure and function in response to altered mechanical loading conditions. In general, mechanical loading at physiological levels is beneficial to tendons, but excessive loading or disuse of tendons is detrimental. This mechanoadaptability is due to the cells present in tendons. Tendon fibroblasts (tenocytes) are the dominant tendon cells responsible for tendon homeostasis and repair. Tendon stem cells (TSCs), which were recently discovered, also play a vital role in tendon maintenance and repair by virtue of their ability to self-renew and differentiate into tenocytes. TSCs may also be responsible for chronic tendon injury, or tendinopathy, by undergoing aberrant differentiation into nontenocytes in response to excessive mechanical loading. Thus, it is necessary to devise optimal rehabilitation protocols to enhance tendon healing while reducing scar tissue formation and tendon adhesions. Moreover, along with scaffolds that can mimic tendon matrix environments and platelet-rich plasma, which serves as a source of growth factors, TSCs may be the optimal cell type for enhancing repair of injured tendons. Copyright © 2012 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  6. Combined Intra- and Extra-articular Reconstruction of the Anterior Cruciate Ligament: The Reconstruction of the Knee Anterolateral Ligament

    PubMed Central

    Helito, Camilo Partezani; Bonadio, Marcelo Batista; Gobbi, Riccardo Gomes; da Mota e Albuquerque, Roberto Freire; Pécora, José Ricardo; Camanho, Gilberto Luis; Demange, Marco Kawamura

    2015-01-01

    We present a new technique for the combined intra- and extra-articular reconstruction of the anterior cruciate ligament. Intra-articular reconstruction is performed in an outside-in manner according to the precepts of the anatomic femoral tunnel technique. Extra-articular reconstruction is performed with the gracilis tendon while respecting the anatomic parameters of the origin and insertion points and the path described for the knee anterolateral ligament. PMID:26258037

  7. Tendon Reattachment to Bone in an Ovine Tendon Defect Model of Retraction Using Allogenic and Xenogenic Demineralised Bone Matrix Incorporated with Mesenchymal Stem Cells.

    PubMed

    Thangarajah, Tanujan; Shahbazi, Shirin; Pendegrass, Catherine J; Lambert, Simon; Alexander, Susan; Blunn, Gordon W

    2016-01-01

    Tendon-bone healing following rotator cuff repairs is mainly impaired by poor tissue quality. Demineralised bone matrix promotes healing of the tendon-bone interface but its role in the treatment of tendon tears with retraction has not been investigated. We hypothesized that cortical demineralised bone matrix used with minimally manipulated mesenchymal stem cells will result in improved function and restoration of the tendon-bone interface with no difference between xenogenic and allogenic scaffolds. In an ovine model, the patellar tendon was detached from the tibial tuberosity and a complete distal tendon transverse defect measuring 1 cm was created. Suture anchors were used to reattach the tendon and xenogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5), or allogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5) were used to bridge the defect. Graft incorporation into the tendon and its effect on regeneration of the enthesis was assessed using histomorphometry. Force plate analysis was used to assess functional recovery. Compared to the xenograft, the allograft was associated with significantly higher functional weight bearing at 6 (P = 0.047), 9 (P = 0.028), and 12 weeks (P = 0.009). In the allogenic group this was accompanied by greater remodeling of the demineralised bone matrix into tendon-like tissue in the region of the defect (p = 0.015), and a more direct type of enthesis characterized by significantly more fibrocartilage (p = 0.039). No failures of tendon-bone healing were noted in either group. Demineralised bone matrix used with minimally manipulated mesenchymal stem cells promotes healing of the tendon-bone interface in an ovine model of acute tendon retraction, with superior mechanical and histological results associated with use of an allograft.

  8. Extensor Tendon Injuries and Repairs in the Hand

    PubMed Central

    Kontor, J. A.

    1982-01-01

    Due to their superficial course, the extensor tendons are frequently lacerated over the dorsum of the hand and fingers. Excellent functional results are obtained in repairs of simple tendon lacerations. ‘Open’ mallet lacerations over the distal IP joint or involving the central extensor slip over the proximal IP joint require more precise suturing methods. More proximal extensor tendon divisions near the wrist involve dissection of the retracted finger extensors or long thumb extensor in the distal forearm and more formal tendon repairs, including a possible tendon transfer to the thumb. ‘Closed injuries’, with varying degrees of extensor tendon disruption, occur at three main sites. The mallet injury at the DIP joint and the boutonnière deformity over the PIP joint are sometimes recognized late, but respond to conservative splinting for a minimum of four weeks with guarded motion avoiding secondary stiffening of the remaining small joints of the hand. Surgery of closed injuries most frequently involves the intra-articular traction fracture type of mallet deformities in which the DIP joint has taken the brunt of the injury. PMID:21286174

  9. Immediate post-operative pain in anterior cruciate ligament reconstruction surgery with bone patellar tendon bone graft versus hamstring graft.

    PubMed

    Gupta, Ravi; Kapoor, Dheeraj; Kapoor, Love; Malhotra, Anubhav; Masih, Gladson David; Kapoor, Anil; Joshi, Shweta

    2016-06-08

    Pain in the immediate post-operative period after anterior cruciate ligament (ACL) surgery, apart from an unpleasant experience for the patient, can act as a barrier for static quadriceps contractions and optimum execution of the initial rehabilitation protocol resulting in slow recovery and a later return to full function for a sportsperson. There is no report in the literature comparing pain in the immediate post-operative period after using the two most widely used autografts, bone patellar tendon bone (BPTB) graft and hamstring graft. The present study compared the visual analogue scale (VAS) pain score in the immediate post-operative period after arthroscopic ACL reconstruction with the BPTB and hamstring autografts. Both groups consisted of 50 patients each. The mean age of the BPTB and hamstring cohorts was 26.9 ± 7.3 years (age range 18-59 years) and 26.7 ± 9.0 years (age range 17-52 years), respectively. Unpaired t test was applied to compare pain scores between the BPTB and hamstring cohorts. In the present study, patients in the BPTB cohort showed higher mean pain scores across all the post-operative time intervals except at 6 h. However, the difference in the mean VAS pain score at post-operative 6, 12,18, 24, 36 and 48 h in the two groups was statistically not significant (p value of 1, 0.665, 0.798, 0.377, 0.651 and 0.215 at 6, 12, 18, 24, 36 and 48 h, respectively). Our study concludes that the arthroscopic ACL reconstruction with BPTB autograft and hamstring autograft is associated with similar pain in the immediate post-operative period. As a result, aggressive physiotherapy regime is not affected by the type of graft being used for ACL reconstruction, as the pain scores in the immediate post-operative period are similar for both techniques. Clinical Trials Registry-India, CTRI/2016/01/006502.

  10. Tendon Reconstruction with Tissue Engineering Approach--A Review.

    PubMed

    Verdiyeva, Gunay; Koshy, Kiron; Glibbery, Natalia; Mann, Haroon; Seifalian, Alexander M

    2015-09-01

    Tendon injuries are a common and rising occurrence, associated with significant impairment to quality of life and financial burden to the healthcare system. Clinically, they represent an unresolved problem, due to poor natural tendon healing and the inability of current treatment strategies to restore the tendon to its native state. Tissue engineering offers a promising alternative, with the incorporation of scaffolds, cells and growth factors to support the complete regeneration of the tendon. The materials used in tendon engineering to date have provided significant advances in structural integrity and biological compatibility and in many cases the results obtained are superior to those observed in natural healing. However, grafts fail to reproduce the qualities of the pre-injured tendon and each has weaknesses subject to its constituent parts. Furthermore, many materials and cell types are being investigated concurrently, with seemingly little association or comparison between research results. In this review the properties of the most-investigated and effective components have been appraised in light of the surrounding literature, with research from early in-vitro experiments to clinical trials being discussed. Extensive comparisons have been made between scaffolds, cell types and growth factors used, listing strengths and weaknesses to provide a stable platform for future research. Promising future endeavours are also described in the field of nanocomposite material science, stem cell sources and growth factors, which may bypass weaknesses found in individual elements. The future of tendon engineering looks bright, with growing understanding in material technology, cell and growth factor application and encouraging recent advances bringing us ever closer to regenerating the native tendon.

  11. Preoperative cryotherapy use in anterior cruciate ligament reconstruction.

    PubMed

    Koyonos, Loukas; Owsley, Kevin; Vollmer, Emily; Limpisvasti, Orr; Gambardella, Ralph

    2014-12-01

    Unrelieved postoperative pain may impair rehabilitation, compromise functional outcomes, and lead to patient dissatisfaction. Preemptive multimodal analgesic techniques may improve outcomes after surgery. We hypothesized that patients using preoperative cryotherapy plus a standardized postoperative treatment plan will have lower pain scores and require less pain medication compared with patients receiving a standardized postoperative treatment plan alone after arthroscopically assisted anterior cruciate ligament reconstruction (ACLR). A total of 53 consecutive patients undergoing arthroscopically assisted ACLR performed by one of seven surgeons were randomly assigned to one of two groups. Group 1 received no preoperative cryotherapy and group 2 received 30 to 90 minutes of preoperative cryotherapy to the operative leg using a commercial noncompressive cryotherapy unit. Visual analog scale pain scores and narcotic use were recorded for the first 4 days postoperatively. Total hours of cold therapy and continuous passive motion (CPM) use and highest degree of flexion achieved were recorded as well. Group 1 consisted of 26 patients (15 allograft Achilles tendon and 11 autograft bone patellar tendon bone [BPTB]), and group 2 consisted of 27 patients (16 allograft Achilles tendon and 11 autograft BPTB). Group 2 patients reported less pain (average 1.3 units, p < 0.02) and used less narcotic use (average 1.7 tablets, p < 0.02) for the first 36 hours compared with group 1. No statistically significant differences were identified between the two groups with regard to demographics, hours of postoperative cryotherapy, hours of CPM use, or maximum knee flexion achieved. Complications did not occur in either group. This is the first report we are aware of showing the postoperative effects of preoperative cryotherapy. Our results support the safety and efficacy of preoperative cryotherapy in a multimodal pain regimen for patients undergoing ACL reconstruction. Thieme

  12. Modelling approaches for evaluating multiscale tendon mechanics

    PubMed Central

    Fang, Fei; Lake, Spencer P.

    2016-01-01

    Tendon exhibits anisotropic, inhomogeneous and viscoelastic mechanical properties that are determined by its complicated hierarchical structure and varying amounts/organization of different tissue constituents. Although extensive research has been conducted to use modelling approaches to interpret tendon structure–function relationships in combination with experimental data, many issues remain unclear (i.e. the role of minor components such as decorin, aggrecan and elastin), and the integration of mechanical analysis across different length scales has not been well applied to explore stress or strain transfer from macro- to microscale. This review outlines mathematical and computational models that have been used to understand tendon mechanics at different scales of the hierarchical organization. Model representations at the molecular, fibril and tissue levels are discussed, including formulations that follow phenomenological and microstructural approaches (which include evaluations of crimp, helical structure and the interaction between collagen fibrils and proteoglycans). Multiscale modelling approaches incorporating tendon features are suggested to be an advantageous methodology to understand further the physiological mechanical response of tendon and corresponding adaptation of properties owing to unique in vivo loading environments. PMID:26855747

  13. Tendon material properties vary and are interdependent among turkey hindlimb muscles.

    PubMed

    Matson, Andrew; Konow, Nicolai; Miller, Samuel; Konow, Pernille P; Roberts, Thomas J

    2012-10-15

    The material properties of a tendon affect its ability to store and return elastic energy, resist damage, provide mechanical feedback and amplify or attenuate muscle power. While the structural properties of a tendon are known to respond to a variety of stimuli, the extent to which material properties vary among individual muscles remains unclear. We studied the tendons of six different muscles in the hindlimb of Eastern wild turkeys to determine whether there was variation in elastic modulus, ultimate tensile strength and resilience. A hydraulic testing machine was used to measure tendon force during quasi-static lengthening, and a stress-strain curve was constructed. There was substantial variation in tendon material properties among different muscles. Average elastic modulus differed significantly between some tendons, and values for the six different tendons varied nearly twofold, from 829±140 to 1479±106 MPa. Tendons were stretched to failure, and the stress at failure, or ultimate tensile stress, was taken as a lower-limit estimate of tendon strength. Breaking tests for four of the tendons revealed significant variation in ultimate tensile stress, ranging from 66.83±14.34 to 112.37±9.39 MPa. Resilience, or the fraction of energy returned in cyclic length changes was generally high, and one of the four tendons tested was significantly different in resilience from the other tendons (range: 90.65±0.83 to 94.02±0.71%). An analysis of correlation between material properties revealed a positive relationship between ultimate tensile strength and elastic modulus (r(2)=0.79). Specifically, stiffer tendons were stronger, and we suggest that this correlation results from a constrained value of breaking strain, which did not vary significantly among tendons. This finding suggests an interdependence of material properties that may have a structural basis and may explain some adaptive responses observed in studies of tendon plasticity.

  14. Surface Modification Counteracts Adverse Effects Associated with Immobilization after Flexor Tendon Repair

    PubMed Central

    Zhao, Chunfeng; Sun, Yu-Long; Jay, Gregory D.; Moran, Steven L.; An, Kai-Nan; Amadio, Peter C.

    2012-01-01

    SUMMARY Although post-rehabilitation is routinely performed following flexor tendon repair, in some clinical scenarios post-rehabilitation must be delayed. We investigated modification of the tendon surface using carbodiimide derivatized hyaluronic acid and lubricin (cd-HA-Lub) to maintain gliding function following flexor tendon repair with postoperative immobilization in a in vivo canine model. Flexor digitorum profundus tendons from the 2nd and 5th digits of one forepaw of six dogs were transected and repaired. One tendon in each paw was treated with cd-HA-Lub; the other repaired tendon was not treated. Following tendon repair, a forearm cast was applied to fully immobilize the operated forelimb for 10 days, after which the animals were euthanized. Digit normalized work of flexion (nWOF) and tendon gliding resistance were assessed. The nWOF of the FDP tendons treated with cd-HA-Lub was significantly lower than the nWOF of the untreated tendons (p < 0.01). The gliding resistance of cd-HA-Lub treated tendons was also significantly lower than that of the untreated tendons (p < 0.05). Surface treatment with cd-HA-Lub following flexor tendon repair provides an opportunity to improve outcomes for patients in whom the post-operative therapy must be delayed after flexor tendon repair. PMID:22714687

  15. Light microscopic histology of supraspinatus tendon ruptures.

    PubMed

    Longo, Umile Giuseppe; Franceschi, Francesco; Ruzzini, Laura; Rabitti, Carla; Morini, Sergio; Maffulli, Nicola; Forriol, Francisco; Denaro, Vincenzo

    2007-11-01

    We analysed the morphological features of the human surgical specimens of supraspinatus tendon from patients with rotator cuff tears. Tendon samples were harvested from 31 subjects (21 men and 10 women; mean age 51 years, range 38-64) who underwent arthroscopic repair of a rotator cuff tear, and from five male patients who died of cardiovascular events (mean age, 69.6 years). Histological examination was performed using Haematoxylin and Eosin, Masson's Trichrome and Van Gieson's connective tissue stain. The specimens were examined twice by the same examiner under white light and polarized light microscopy. Particular effort was made to assess any evidence of the changes associated with tendinopathy. Within each specific category of tendon abnormalities, the chi-square test showed significant differences between the control and ruptured tendons (P < 0.05). Using the kappa statistics, the agreement between the two readings ranged from 0.57 to 0.84. We found thinning and disorientation of collagen fibres and chondroid metaplasia to be more pronounced on the articular side of the specimens from patients with rotator cuff tear (P < 0.05). The present study provides a description of the histological architecture of human surgical specimens of normal supraspinatus tendon from patients with rotator cuff tears and demonstrates more frequent tendon changes on the articular side of the rotator cuff.

  16. Flexor Tendon Repair With Looped Suture: 1 Versus 2 Knots.

    PubMed

    Gil, Joseph A; Skjong, Christian; Katarincic, Julia A; Got, Christopher

    2016-03-01

    To assess the strength of flexor tendon repair with looped suture. We hypothesized that, after passing the intact looped suture in the desired repair configuration, splitting the loop and tying 2 independent knots would increase the strength of flexor tendon repair. Thirty-two flexor tendons were harvested and were sharply transected in zone II. The tendons were repaired with a 4-strand core suture repair using 3-0 looped nonabsorbable nylon suture. The harvested tendons were randomly assigned and repaired with either a 1- or a 2-knot construct. The repaired flexor tendons were fixed in a servohydraulic material testing system and were loaded to failure either with uniaxial tension or cyclically. The average force at failure was 43 N for the 1-knot repair and 28 N for the 2-knot repair. The mode of failure of 15 of the flexor tendon repairs that were cyclically loaded to failure was suture pull-out. The average number of cycles and force in cyclic testing that caused failure of flexor tendon repairs was 134 cycles and 31 N for tendons repaired with looped 3-0 suture tied with 1 knot and 94 cycles and 33 N for tendons repaired with looped 3-0 suture tied with 2 knots. Our hypothesis was disproved by the results of this study. This study suggests that, when using looped suture, tying 2 independent knots instead of tying a single knot does not increase the strength of the flexor tendon repair. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. A Rare Case of Massive Rotator Cuff Tear and Biceps Tendon Rupture with Posterior Shoulder Dislocation in a Young Adult - Surgical Decision-making and Outcome

    PubMed Central

    Soon, En Loong; Razak, Hamid Rahmatullah Bin Abd; Tan, Andrew Hwee Chye

    2017-01-01

    Introduction: Massive rotator cuff tears (RCTs) in the context of shoulder dislocations are relatively uncommon in the young adult (<40 years) and if reported are more commonly described in association with acute traumatic anterior glenohumeral dislocations. They have rarely been described with posterior dislocations, regardless of patient age. This is the 1st case reported in the context of posterior dislocations, where a triad of biceps tendon rupture, posterior dislocation, and RCTs was observed during surgery. It provides an important reminder to readers about certain injuries commonly overlooked during the assessment of an acute traumatic shoulder. Case Report: We report an atypical case of a massive RCT involving a 34-year-old Asian male who landed on his outstretched hand after falling off a bicycle. A tear involving the supraspinatus and subscapularis was visualized during surgery, along with long head of biceps (LHB) tendon rupture. This was after an initial failure to achieve closed reduction of the posteriorly dislocated left shoulder. Conclusion: It is easy to miss the posterior instability, the associated RCTs or the biceps tendon injuries. Biceps tendon rupture should be a consideration when one is unable to reduce a posteriorly dislocated shoulder. The interposed torn LHB tendon trapped within the glenohumeral joint was the likely physical block in the initial failure to achieve closed reduction. With timely diagnosis, prudent physical examination, early imaging and surgery, and excellent results can potentially be achieved to return a young patient to full functionality. PMID:28819610

  18. Muscle-Tendon-Enthesis Unit.

    PubMed

    Tadros, Anthony S; Huang, Brady K; Pathria, Mini N

    2018-07-01

    Injuries to the muscle-tendon-enthesis unit are common and a significant source of pain and loss of function. This article focuses on the important anatomical and biomechanical considerations for each component of the muscle-tendon-enthesis unit. We review normal and pathologic conditions affecting this unit, illustrating the imaging appearance of common disorders on magnetic resonance imaging and ultrasound. Knowledge of the anatomy and biomechanics of these structures is crucial for the radiologist to make accurate diagnoses and provide clinically relevant assessments. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. Arthroscopic anterior cruciate ligament reconstruction using the double press- fit technique: an alternative to interference screw fixation.

    PubMed

    Halder, Andreas M; Ludwig, Silke; Neumann, Wolfram

    2002-01-01

    Patellar tendon autograft fixation in arthroscopic anterior cruciate ligament reconstruction is commonly accomplished using interference screws. However, improper insertion of the screws may reduce primary stability, injure the posterior femoral cortex, or displace hardware into the joint. Even if placed properly, metallic screws interfere with postoperative magnetic resonance imaging. In case of revision surgery, removing screws may be difficult and leaves bone defects. Retrospective study. An arthroscopic technique was developed that achieves patellar tendon autograft fixation by press-fit without any supplemental internal fixation. Forty patients were examined clinically and by KT-1000 arthrometer 28.7 months (range, 22 to 40 months) postoperatively. The mean difference in side-to-side laxity was 1.3 mm (SD 2.2) and the results according to the IKDC score were as follows: 7 A, 28 B, 5 C, and 0 D. The double press-fit technique we present avoids all complications related to the use of interference screws and creates an ideal environment for osseous integration of the bone-patellar tendon-bone autograft. Concurrently, it achieves a stable fixation of the autograft and allows early functional rehabilitation. However, fixation strength depends on bone quality and the arthroscopic procedure is demanding.

  20. Platelet-rich plasma in tendon-related disorders: results and indications.

    PubMed

    Filardo, Giuseppe; Di Matteo, Berardo; Kon, Elizaveta; Merli, Giulia; Marcacci, Maurilio

    2016-09-24

    Platelet-rich plasma (PRP) is currently the most exploited strategy in the clinical practice to provide a regenerative stimulus for tendon healing. The aim of the present study was to systematically review the available evidence on the treatment of the main tendon disorders where PRP is currently applied. A systematic review of the literature was performed on the use of PRP as a treatment for tendinopathies focusing on the following sites: Achilles tendon, patellar tendon, rotator cuff tendons, and lateral elbow tendons. The following inclusion criteria for relevant articles were used: clinical trials written in English language up to 21 June 2016 on the use of PRP in the conservative or surgical treatment of the aforementioned tendinopathies. The research identified the following clinical trials dealing with the application of PRP in the selected tendons: 19 papers on patellar tendon (6 being RCTs: 4 dealing with PRP conservative application and 2 surgical), 24 papers on Achilles tendon (4 RCTs: 3 conservative and 1 surgical), 29 on lateral elbow tendons (17 RCTs, all conservative), and 32 on rotator cuff (22 RCTs: 18 surgical and 3 conservative). Patellar tendons seem to benefit from PRP injections, whereas in the Achilles tendon, PRP application is not indicated neither as a conservative approach nor as a surgical augmentation. Lateral elbow tendinopathy showed an improvement in most of the high-level studies, but the lack of proven superiority with respect to the more simple whole-blood injections still questions its use in the clinical practice. With regard to rotator cuff pathology, the vast majority of surgical RCTs documented a lack of beneficial effects, whereas there is still inconclusive evidence concerning its conservative application in rotator cuff disorders. Systematic review of level I-IV trials, Level IV.

  1. Secure fixation of femoral bone plug with a suspensory button in anatomical anterior cruciate ligament reconstruction with bone-patellar tendon-bone graft

    PubMed Central

    TAKETOMI, SHUJI; INUI, HIROSHI; NAKAMURA, KENSUKE; YAMAGAMI, RYOTA; TAHARA, KEITARO; SANADA, TAKAKI; MASUDA, HIRONARI; TANAKA, SAKAE; NAKAGAWA, TAKUMI

    2015-01-01

    Purpose the efficacy and safety of using a suspensory button for femoral fixation in anatomical anterior cruciate ligament (ACL) reconstruction with bone-patellar tendon-bone (BPTB) graft have not been established. The purpose of the current study was to evaluate bone plug integration onto the femoral socket and migration of the bone plug and the EndoButton (EB) (Smith & Nephew, Andover, MA, USA) after rectangular tunnel ACL reconstruction with BPTB autograft. Methods thirty-four patients who underwent anatomical rectangular ACL reconstruction with BPTB graft using EB for femoral fixation and in whom three-dimensional (3D) computed tomography (CT) was performed one week and one year after surgery were included in this study. Bone plug integration onto the femoral socket, bone plug migration, soft tissue interposition, EB migration and EB rotation were evaluated on 3D CT. The clinical outcome was also assessed and correlated with the imaging outcomes. Results the bone plug was integrated onto the femoral socket in all cases. The incidence of bone plug migration, soft tissue interposition, EB migration and EB rotation was 15, 15, 9 and 56%, respectively. No significant association was observed between the imaging outcomes. The postoperative mean Lysholm score was 97.1 ± 5.0 points. The postoperative side-to-side difference, evaluated using a KT-2000 arthrometer, averaged 0.5 ± 1.3 mm. There were no complications associated with EB use. Imaging outcomes did not affect the postoperative KT side-to-side difference. Conclusions the EB is considered a reliable device for femoral fixation in anatomical rectangular tunnel ACL reconstruction with BPTB autograft. Level of evidence Level IV, therapeutic case series. PMID:26889465

  2. Sonographic differentiation of digital tendon rupture from adhesive scarring after primary surgical repair.

    PubMed

    Budovec, Joseph J; Sudakoff, Gary S; Dzwierzynski, William W; Matloub, Hani S; Sanger, James R

    2006-04-01

    After the surgical repair of finger tendons finger range of motion may be limited by tendon rupture or adhesive scarring. Differentiating tendon rupture from adhesive scarring may be difficult clinically. Digital tendon sonography allows the evaluation of tendon integrity in a dynamic setting. Our objective was to determine if sonography could differentiate tendon rupture from adhesive scarring in patients who have had primary tendon repair. A retrospective review was performed of the radiographic, clinical, and surgical records of patients referred for finger sonography over a 2-year period. Twenty-eight digits in 21 patients were evaluated for finger tendon disruption after primary surgical repair. The diagnosis of complete tendon rupture was made when 1 or more of the following was identified: a gap separating the proximal and distal tendon margins, visualization of only the proximal tendon margin, or visualization of only the distal tendon margin. Adhesive scarring was diagnosed if the tendon appeared intact with abnormal peritendinous soft tissue abutting or partially encasing the tendon, with synovial sheath thickening, or with restricted tendon motion during dynamic evaluation. Sonography correctly identified tendon rupture or adhesive scarring in 27 of 28 digits with 1 false-positive case (sensitivity, 100%; specificity, 93%; positive-predictive value, 93%; negative-predictive value, 100%; accuracy, 96%). Sonography is an accurate modality for differentiating tendon rupture from adhesive scarring in patients with prior surgical tendon repair. Diagnostic, Level I.

  3. The role of the non-collagenous matrix in tendon function.

    PubMed

    Thorpe, Chavaunne T; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2013-08-01

    Tendon consists of highly ordered type I collagen molecules that are grouped together to form subunits of increasing diameter. At each hierarchical level, the type I collagen is interspersed with a predominantly non-collagenous matrix (NCM) (Connect. Tissue Res., 6, 1978, 11). Whilst many studies have investigated the structure, organization and function of the collagenous matrix within tendon, relatively few have studied the non-collagenous components. However, there is a growing body of research suggesting the NCM plays an important role within tendon; adaptations to this matrix may confer the specific properties required by tendons with different functions. Furthermore, age-related alterations to non-collagenous proteins have been identified, which may affect tendon resistance to injury. This review focuses on the NCM within the tensional region of developing and mature tendon, discussing the current knowledge and identifying areas that require further study to fully understand structure-function relationships within tendon. This information will aid in the development of appropriate techniques for tendon injury prevention and treatment. © 2013 The Authors. International Journal of Experimental Pathology © 2013 International Journal of Experimental Pathology.

  4. Postinjury biomechanics of Achilles tendon vary by sex and hormone status

    PubMed Central

    Fryhofer, George W.; Freedman, Benjamin R.; Hillin, Cody D.; Salka, Nabeel S.; Pardes, Adam M.; Weiss, Stephanie N.; Farber, Daniel C.

    2016-01-01

    Achilles tendon ruptures are common injuries. Sex differences are present in mechanical properties of uninjured Achilles tendon, but it remains unknown if these differences extend to tendon healing. We hypothesized that ovariectomized females (OVX) and males would exhibit inferior postinjury tendon properties compared with females. Male, female, and OVX Sprague-Dawley rats (n = 32/group) underwent acclimation and treadmill training before blunt transection of the Achilles tendon midsubstance. Injured hindlimbs were immobilized for 1 wk, followed by gradual return to activity and assessment of active and passive hindlimb function. Animals were euthanized at 3 or 6 wk postinjury to assess tendon structure, mechanics, and composition. Passive ankle stiffness and range of motion were superior in females at 3 wk; however, by 6 wk, passive and active function were similar in males and females but remained inferior in OVX. At 6 wk, female tendons had greater normalized secant modulus, viscoelastic behavior, and laxity compared with males. Normalized secant modulus, cross-sectional area and tendon glycosaminoglycan composition were inferior in OVX compared with females at 6 wk. Total fatigue cycles until tendon failure were similar among groups. Postinjury muscle fiber size was better preserved in females compared with males, and females had greater collagen III at the tendon injury site compared with males at 6 wk. Despite male and female Achilles tendons withstanding similar durations of fatigue loading, early passive hindlimb function and tendon mechanical properties, including secant modulus, suggest superior healing in females. Ovarian hormone loss was associated with inferior Achilles tendon healing. PMID:27633741

  5. Supraspinatus tendon micromorphology in individuals with subacromial pain syndrome.

    PubMed

    Pozzi, Federico; Seitz, Amee L; Plummer, Hillary A; Chow, Kira; Bashford, Gregory R; Michener, Lori A

    Cross-sectional cohort. Tendon collagen organization can be estimated by peak spatial frequency radius (PSFR) on ultrasound images. Characterizing PSFR can define the contribution of collagen disruption to shoulder symptoms. The purpose of this was to characterize the (1) supraspinatus tendon PSFR in participants with subacromial pain syndrome (SPS) and healthy controls; (2) PSFR between participants grouped on a tendon visual quality score; and (3) relationship between PSFR with patient-reported pain, function, and shoulder strength. Participants with SPS (n = 20) and age, sex, and arm-dominance-matched healthy controls (n = 20) completed strength testing in scaption and external rotation, and patient-reported pain, and functional outcomes. Supraspinatus tendon ultrasound images were acquired, and PSFR was calculated for a region of interest 15 mm medial to the supraspinatus footprint. PSFR was compared between groups using an independent t-test and an analysis of variance to compare between 3 groups for visually qualitatively rated tendon abnormalities. Relationships between PSFR with pain, function, and strength were assessed using Pearson correlation coefficient. Supraspinatus tendon PSFR was not different between groups (P = .190) or tendon qualitative ratings (P = .556). No relationship was found between PSFR and pain, functional loss, and strength (P > .05). Collagen disruption (PSFR) measured via ultrasound images of the supraspinatus tendon was not different between participants with SPS or in those with visually rated tendon defects. PSFR is not related to shoulder pain, function, and strength, suggesting that supraspinatus tendon collagen disorganization may not be a contributing factor to shoulder SPS. However, collagen disruption may not be isolated to a single region of interest. 3b: case-control study. Copyright © 2017 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  6. Step Cut Lengthening: A Technique for Treatment of Flexor Pollicis Longus Tendon Rupture.

    PubMed

    Chong, Chew-Wei; Chen, Shih-Heng

    2018-04-01

    Reconstruction of a tendon defect is a challenging task in hand surgery. Delayed repair of a ruptured flexor pollicis longus (FPL) tendon is often associated with tendon defect. Primary repair of the tendon is often not possible, particularly after debridement of the unhealthy segment of the tendon. As such, various surgical treatments have been described in the literature, including single-stage tendon grafting, 2-stage tendon grafting, flexor digitorum superficialis tendon transfer from ring finger, and interphalangeal joint arthrodesis. We describe step cut lengthening of FPL tendon for the reconstruction of FPL rupture. This is a single-stage reconstruction without the need for tendon grafting or tendon transfer. To our knowledge, no such technique has been previously described.

  7. Multiple variations of the tendons of the anatomical snuffbox.

    PubMed

    Thwin, San San; Fazlin, Fazlin; Than, Myo

    2014-01-01

    Multiple tendons of the abductor pollicis longus (APL) in the anatomical snuffbox of the wrist can lead to the development of de Quervain's syndrome, which is caused by stenosing tenosynovitis. A cadaveric study was performed to establish the variations present in the tendons of the anatomical snuffbox in a Malaysian population, in the hope that this knowledge would aid clinical investigation and surgical treatment of de Quervain's tenosynovitis. Routine dissection of ten upper limbs was performed to determine the variations in the tendons of the anatomical snuffbox of the wrist. In all the dissected upper limbs, the APL tendon of the first extensor compartment was found to have several (3-14) tendon slips. The insertion of the APL tendon slips in all upper limbs were at the base of the first metacarpal bone, trapezium and fascia of the opponens pollicis muscle; however, in seven specimens, they were also found to be attached to the fleshy belly of the abductor pollicis brevis muscle. In two specimens, double tendons of the extensor pollicis longus located in the third extensor compartment were inserted into the capsule of the proximal interphalangeal joints before being joined to the extensor expansion. In two other specimens, the first extensor compartment had two osseofibrous tunnels divided by a septum that separated the APL tendon from the extensor pollicis brevis tendon. Multiple variations were found in the anatomical snuffbox region of the dissected upper limbs. Knowledge of these variations would be useful in interventional radiology and orthopaedic surgery.

  8. Multiple variations of the tendons of the anatomical snuffbox

    PubMed Central

    Thwin, San San; Zaini, Fazlin; Than, Myo

    2014-01-01

    INTRODUCTION Multiple tendons of the abductor pollicis longus (APL) in the anatomical snuffbox of the wrist can lead to the development of de Quervain's syndrome, which is caused by stenosing tenosynovitis. A cadaveric study was performed to establish the variations present in the tendons of the anatomical snuffbox in a Malaysian population, in the hope that this knowledge would aid clinical investigation and surgical treatment of de Quervain's tenosynovitis. METHODS Routine dissection of ten upper limbs was performed to determine the variations in the tendons of the anatomical snuffbox of the wrist. RESULTS In all the dissected upper limbs, the APL tendon of the first extensor compartment was found to have several (3–14) tendon slips. The insertion of the APL tendon slips in all upper limbs were at the base of the first metacarpal bone, trapezium and fascia of the opponens pollicis muscle; however, in seven specimens, they were also found to be attached to the fleshy belly of the abductor pollicis brevis muscle. In two specimens, double tendons of the extensor pollicis longus located in the third extensor compartment were inserted into the capsule of the proximal interphalangeal joints before being joined to the extensor expansion. In two other specimens, the first extensor compartment had two osseofibrous tunnels divided by a septum that separated the APL tendon from the extensor pollicis brevis tendon. CONCLUSION Multiple variations were found in the anatomical snuffbox region of the dissected upper limbs. Knowledge of these variations would be useful in interventional radiology and orthopaedic surgery. PMID:24452976

  9. Prevalence and Role of a Low-Lying Peroneus Brevis Muscle Belly in Patients With Peroneal Tendon Pathologic Features: A Potential Source of Tendon Subluxation.

    PubMed

    Mirmiran, Roya; Squire, Chad; Wassell, Daniel

    2015-01-01

    A peroneus brevis low-lying muscle belly (LLMB) is a rare anomaly. A few published studies have supported the presence of this anomaly as an etiology for a peroneal tendon tear. However, the association between a peroneus brevis LLMB and tendon subluxation has not been well explored. In the present retrospective study, the magnetic resonance imaging (MRI) and intraoperative findings of 50 consecutive patients undergoing primary peroneal tendon surgery during a 5-year period were assessed. The sensitivity and specificity of MRI compared with the intraoperative findings for identifying peroneal tendon disease were investigated. The presence of associated peroneal tendon pathologic features in patients with and without a peroneus brevis LLMB was also compared. The sensitivity of MRI was high for identifying peroneal tenosynovitis (81.58%) and tear (85.71%). Although the sensitivity of MRI for detecting a peroneus brevis LLMB (3.23%) and tendon subluxation (10.00%) was low, MRI had high specificity at 94.74% and 100%, respectively. Intraoperatively, a peroneus brevis LLMB was seen in 62.00% of the patients with chronic lateral ankle pain and was associated with 64.52% of the patients with tenosynovitis, 29.03% of those with tendon subluxation, and 80.65% of those with a peroneus brevis tendon tear. Although the presence of a peroneus brevis LLMB did not show any statistically significant association with peroneus brevis tendon subluxation, of the 10 patients with intraoperatively observed tendon subluxation, 9 had a concomitant peroneus brevis LLMB. More studies with larger patient populations are needed to better investigate the role of a peroneus brevis LLMB as a mass-occupying lesion resulting in peroneal tendon subluxation. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  10. FROM ACUTE ACHILLES TENDON RUPTURE TO RETURN TO PLAY - A CASE REPORT EVALUATING RECOVERY OF TENDON STRUCTURE, MECHANICAL PROPERTIES, CLINICAL AND FUNCTIONAL OUTCOMES.

    PubMed

    Zellers, Jennifer A; Cortes, Daniel H; Silbernagel, Karin Grävare

    2016-12-01

    Achilles tendon rupture results in significant functional deficits regardless of treatment strategy (surgical versus non-surgical intervention). Recovery post-rupture is highly variable, making comprehensive patient assessment critical. Assessment tools may change along the course of recovery as the patient progresses - for instance, moving from a seated heel-rise to standing heel-rise to jump testing. However, tools that serve as biomarkers for early recovery may be particularly useful in informing clinical decision-making. The purpose of this case report was to describe the progress of a young, athletic individual following Achilles tendon rupture managed non-surgically, using patient reported and functional performance outcome measures and comprehensively evaluating Achilles tendon structure and function incorporating a novel imaging technique (cSWE). The subject is a 26 year-old, female basketball coach who sustained an Achilles tendon rupture and was managed non-surgically. The subject was able to steadily progress using a gradual tendon loading treatment approach well-supported by the literature. Multiple evaluative techniques including the addition of diagnostic ultrasound imaging and continuous shear wave elastography (cSWE) to standard clinical tests and measures were used to assess patient-reported symptoms, tendon structure, and tendon functional performance. Five assessments were performed over the course of 2-14 months post-rupture. By the 14-month follow-up, the subject had achieved full self-reported function. Tendon structural and mechanical properties showed similar shear modulus by 14 months, however, viscosity continued to be lower and tendon length longer on the ruptured side. Functional performance, evidenced by the heel-rise test and jump tests, also showed a positive trajectory, however, deficits of 12-28% remained between ruptured and non-ruptured sides at 14 months. This case report outlines comprehensive outcomes assessment in an athletic

  11. Cell-laden composite suture threads for repairing damaged tendons.

    PubMed

    Costa-Almeida, Raquel; Domingues, Rui M A; Fallahi, Afsoon; Avci, Huseyin; Yazdi, Iman K; Akbari, Mohsen; Reis, Rui L; Tamayol, Ali; Gomes, Manuela E; Khademhosseini, Ali

    2018-04-01

    Tendons have limited regenerative capacity due to their low cellularity and hypovascular nature, which results in poor clinical outcomes of presently used therapies. As tendon injuries are often observed in active adults, it poses an increasing socio-economic burden on healthcare systems. Currently, suture threads are used during surgical repair to anchor the tissue graft or to connect injured ends. Here, we created composite suture threads coated with a layer of cell-laden hydrogel that can be used for bridging the injured tissue aiming at tendon regeneration. In addition, the fibres can be used to engineer 3-dimensional constructs through textile processes mimicking the architecture and mechanical properties of soft tissues, including tendons and ligaments. Encapsulated human tendon-derived cells migrated within the hydrogel and aligned at the surface of the core thread. An up-regulation of tendon-related genes (scleraxis and tenascin C) and genes involved in matrix remodelling (matrix metalloproteinases 1, matrix metalloproteinases 2) was observed. Cells were able to produce a collagen-rich matrix, remodelling their micro-environment, which is structurally comparable to native tendon tissue. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Etiology and pathophysiology of tendon ruptures in sports.

    PubMed

    Kannus, P; Natri, A

    1997-04-01

    Of all spontaneous tendon ruptures, complete Achilles tendon tears are most closely associated with sports activities (1-3). Schönbauer (3) reported that 75% of all ruptures of the Achilles tendon are related to sports. In Plecko & Passl (2) the number was 60%. In our material of 430 cases, the number of sports-related Achilles ruptures was very similar (62%), while only 2% of ruptures of other tendons were sports-related (P < 0.001) (1). Also, the majority of Achilles reruptures occurred in sports. The ruptures occurred most often in soccer (34%), track and field (16%) and basketball (14%). The distribution of Achilles ruptures according to different sports varies considerably from country to country, according to the national sport traditions. For example, in northern and middle Europe, soccer, tennis, track and field, indoor ball games, downhill skiing, and gymnastics are the most common; and in North America, football, basketball, baseball, tennis and downhill skiing dominate the statistics (1, 2, 4). In sports, some Achilles ruptures are not spontaneous or degeneration-induced but may occur as a consequence of the remarkably high forces that are involved in the performance (2). Ruptures in the high jump or triple jump are good examples. In such cases, failure in the neuromuscular protective mechanisms due to fatigue or disturbed co-ordination can frequently be found. The spontaneous complete rupture of the supraspinatus tendon of the rotator cuff does not occur very frequently in sports. Those sports that include high-energy throwing movements, such as American and Finnish baseball, American football, rugby and discuss and javelin throwing, may, however, produce this injury. Partial tears and inflammations of the rotator cuff complex are much more frequent in throwing sports. The complete rupture of the proximal long head of the biceps brachii tendon is rare among competitive and recreational athletes. In our material, under 2% of these ruptures were

  13. Dental pulp stem cells express tendon markers under mechanical loading and are a potential cell source for tissue engineering of tendon-like tissue.

    PubMed

    Chen, Yu-Ying; He, Sheng-Teng; Yan, Fu-Hua; Zhou, Peng-Fei; Luo, Kai; Zhang, Yan-Ding; Xiao, Yin; Lin, Min-Kui

    2016-12-16

    Postnatal mesenchymal stem cells have the capacity to differentiate into multiple cell lineages. This study explored the possibility of dental pulp stem cells (DPSCs) for potential application in tendon tissue engineering. The expression of tendon-related markers such as scleraxis, tenascin-C, tenomodulin, eye absent homologue 2, collagens I and VI was detected in dental pulp tissue. Interestingly, under mechanical stimulation, these tendon-related markers were significantly enhanced when DPSCs were seeded in aligned polyglycolic acid (PGA) fibre scaffolds. Furthermore, mature tendon-like tissue was formed after transplantation of DPSC-PGA constructs under mechanical loading conditions in a mouse model. This study demonstrates that DPSCs could be a potential stem cell source for tissue engineering of tendon-like tissue.

  14. Tendon material properties vary and are interdependent among turkey hindlimb muscles

    PubMed Central

    Matson, Andrew; Konow, Nicolai; Miller, Samuel; Konow, Pernille P.; Roberts, Thomas J.

    2012-01-01

    SUMMARY The material properties of a tendon affect its ability to store and return elastic energy, resist damage, provide mechanical feedback and amplify or attenuate muscle power. While the structural properties of a tendon are known to respond to a variety of stimuli, the extent to which material properties vary among individual muscles remains unclear. We studied the tendons of six different muscles in the hindlimb of Eastern wild turkeys to determine whether there was variation in elastic modulus, ultimate tensile strength and resilience. A hydraulic testing machine was used to measure tendon force during quasi-static lengthening, and a stress–strain curve was constructed. There was substantial variation in tendon material properties among different muscles. Average elastic modulus differed significantly between some tendons, and values for the six different tendons varied nearly twofold, from 829±140 to 1479±106 MPa. Tendons were stretched to failure, and the stress at failure, or ultimate tensile stress, was taken as a lower-limit estimate of tendon strength. Breaking tests for four of the tendons revealed significant variation in ultimate tensile stress, ranging from 66.83±14.34 to 112.37±9.39 MPa. Resilience, or the fraction of energy returned in cyclic length changes was generally high, and one of the four tendons tested was significantly different in resilience from the other tendons (range: 90.65±0.83 to 94.02±0.71%). An analysis of correlation between material properties revealed a positive relationship between ultimate tensile strength and elastic modulus (r2=0.79). Specifically, stiffer tendons were stronger, and we suggest that this correlation results from a constrained value of breaking strain, which did not vary significantly among tendons. This finding suggests an interdependence of material properties that may have a structural basis and may explain some adaptive responses observed in studies of tendon plasticity. PMID:22771746

  15. It's positive to be negative: Achilles tendon work loops during human locomotion.

    PubMed

    Zelik, Karl E; Franz, Jason R

    2017-01-01

    Ultrasound imaging is increasingly used with motion and force data to quantify tendon dynamics during human movement. Frequently, tendon dynamics are estimated indirectly from muscle fascicle kinematics (by subtracting muscle from muscle-tendon unit length), but there is mounting evidence that this Indirect approach yields implausible tendon work loops. Since tendons are passive viscoelastic structures, when they undergo a loading-unloading cycle they must exhibit a negative work loop (i.e., perform net negative work). However, prior studies using this Indirect approach report large positive work loops, often estimating that tendons return 2-5 J of elastic energy for every 1 J of energy stored. More direct ultrasound estimates of tendon kinematics have emerged that quantify tendon elongations by tracking either the muscle-tendon junction or localized tendon tissue. However, it is unclear if these yield more plausible estimates of tendon dynamics. Our objective was to compute tendon work loops and hysteresis losses using these two Direct tendon kinematics estimates during human walking. We found that Direct estimates generally resulted in negative work loops, with average tendon hysteresis losses of 2-11% at 1.25 m/s and 33-49% at 0.75 m/s (N = 8), alluding to 0.51-0.98 J of tendon energy returned for every 1 J stored. We interpret this finding to suggest that Direct approaches provide more plausible estimates than the Indirect approach, and may be preferable for understanding tendon energy storage and return. However, the Direct approaches did exhibit speed-dependent trends that are not consistent with isolated, in vitro tendon hysteresis losses of about 5-10%. These trends suggest that Direct estimates also contain some level of error, albeit much smaller than Indirect estimates. Overall, this study serves to highlight the complexity and difficulty of estimating tendon dynamics non-invasively, and the care that must be taken to interpret biological function from

  16. Interactions between COL5A1 Gene and Risk of the Anterior Cruciate Ligament Rupture.

    PubMed

    Lulińska-Kuklik, Ewelina; Rahim, Masouda; Domańska-Senderowska, Daria; Ficek, Krzysztof; Michałowska-Sawczyn, Monika; Moska, Waldemar; Kaczmarczyk, Mariusz; Brzeziański, Michał; Brzeziańska-Lasota, Ewa; Cięszczyk, Paweł; September, Alison V

    2018-06-01

    Collagen alpha-1(V) chain, encoded by the COL5A1 gene, plays a crucial role in abundant fibrillar collagens supporting many tissues in the body containing type I collagen and appears to regulate the association between heterotypic fibers composed of both type I and type V collagen occurring among others in muscles, tendons and ligaments. Taking this fact into consideration we decided to examine the association between COL5A1 rs12722 and rs13946 polymorphisms, individually and as inferred haplotypes, with anterior cruciate ligament rupture risk (ACLR) in professional soccer players. A total of 134 male professional soccer players with surgically diagnosed primary anterior cruciate ligament ruptures and 211 apparently healthy male professional soccer players, who were without any self-reported history of ligament or tendon injury, were included in the study. Both the cases and the healthy controls were recruited from the same soccer teams, of a similar age category, and had a comparable level of exposure to anterior cruciate ligament injury. Genomic DNA was extracted from oral epithelial cells using GenElute Mammalian Genomic DNA MiniprepKit. All samples were genotyped for the rs12722 and rs13946 polymorphisms using a Rotor-Gene realtime polymerase chain reaction. Statistically significant differences in the genotype frequencies for the COL5A1 rs13946 polymorphisms in dominant modes of inheritance occurred (p = 0.039). Statistically significant differences were documented only in the dominant model under the representation tendency of the C-C haplotype in the ACLR group compared to controls (p = 0.038). Our results suggest that variation in the COL5A1 gene may be one of the non-modifiable factors associated with the ACL injury in professional soccer players. The C-C rs12722-rs13946 haplotype provides a protective effect against the ACL tear.

  17. [Ultrasound diagnostics of muscle and tendon injuries].

    PubMed

    Stević, Ruza; Masulović, Dragan

    2009-01-01

    Sonography is a useful technique for the investigation of a number of musculoskeletal disorders. The most common indication for ultrasonography of muscles and tendons is the diagnosis of traumatic lesions, distinguishing them from other disorders and follow- up of healing process. The purpose of this paper is to show the importance of ultrasound in the diagnosis of muscle and tendon injuries. The study included 170 patients (148 male and 22 female), mean age 29.6 years (range 14-60 years). All examinations were performed by linear transducer of 7.5-10 MHz, with longitudinal and transverse scanning. Ultrasound examination followed physical examination. Traumatic lesions of muscles were diagnosed in 113 patients (66.7%) and tendon injuries in 57 cases (33.2%). The muscle changes detected by ultrasonography were the following: 70 (61.9%) partial and two (1.76%) complete ruptures, 22 (19.46%) haematoma, 9 (7.96%) strains grade I, 4 fibroses and 4 ossifying myositis 4 (3.5%, respectively). Complications of muscle injuries were diagnosed in two cases, a muscular hernia and an arteriovenous fistula. Among tendon injuries, 21 (33.8%) ruptures and 36 (66.1%) tendinitis were diagnosed. Accompanying effusion in the bursa of patients with tendon injuries was found in 9 cases. Ultrasonography allowed visualization and objective assessment of the type and the extent of traumatic pathomorphological changes of muscles and tendons. Such diagnostic possibilities of ultrasonography are especially important in the choice of appropriate therapy.

  18. Central Tendon Injuries of Hamstring Muscles: Case Series of Operative Treatment.

    PubMed

    Lempainen, Lasse; Kosola, Jussi; Pruna, Ricard; Puigdellivol, Jordi; Sarimo, Janne; Niemi, Pekka; Orava, Sakari

    2018-02-01

    As compared with injuries involving muscle only, those involving the central hamstring tendon have a worse prognosis. Limited information is available regarding the surgical treatment of central tendon injuries of the hamstrings. To describe the operative treatment and outcomes of central tendon injuries of the hamstrings among athletes. Case series; Level of evidence, 4. Eight athletes (6 top level, 2 recreational) with central hamstring tendon injuries underwent magnetic resonance imaging and surgical treatment. The indication for surgery was recurrent (n = 6) or acute (n = 2) central hamstring tendon injury. All patients followed the same postoperative rehabilitation protocol, and return to play was monitored. Magnetic resonance imaging found a central tendon injury in all 3 hamstring muscles (long head of the biceps femoris, semimembranosus, and semitendinosus) with disrupted tendon ends. In acute and recurrent central tendon injuries, full return to play was achieved at 2.5 to 4 months. There were no adverse events during follow-up. Central tendon injuries of the hamstrings can be successfully repaired surgically after acute and recurrent ruptures.

  19. Central Tendon Injuries of Hamstring Muscles: Case Series of Operative Treatment

    PubMed Central

    Lempainen, Lasse; Kosola, Jussi; Pruna, Ricard; Puigdellivol, Jordi; Sarimo, Janne; Niemi, Pekka; Orava, Sakari

    2018-01-01

    Background: As compared with injuries involving muscle only, those involving the central hamstring tendon have a worse prognosis. Limited information is available regarding the surgical treatment of central tendon injuries of the hamstrings. Purpose: To describe the operative treatment and outcomes of central tendon injuries of the hamstrings among athletes. Study Design: Case series; Level of evidence, 4. Methods: Eight athletes (6 top level, 2 recreational) with central hamstring tendon injuries underwent magnetic resonance imaging and surgical treatment. The indication for surgery was recurrent (n = 6) or acute (n = 2) central hamstring tendon injury. All patients followed the same postoperative rehabilitation protocol, and return to play was monitored. Results: Magnetic resonance imaging found a central tendon injury in all 3 hamstring muscles (long head of the biceps femoris, semimembranosus, and semitendinosus) with disrupted tendon ends. In acute and recurrent central tendon injuries, full return to play was achieved at 2.5 to 4 months. There were no adverse events during follow-up. Conclusion: Central tendon injuries of the hamstrings can be successfully repaired surgically after acute and recurrent ruptures. PMID:29479545

  20. The histology of tendon attachments to bone in man.

    PubMed Central

    Benjamin, M; Evans, E J; Copp, L

    1986-01-01

    Based on a parallel study of a wide range of human tendons from embalmed dissecting room subjects and from a study of dried bones, an explanation is offered for the well known similarity in gross appearance between the markings left by certain tendons (e.g. those of the rotator cuff) and by articular surfaces on dried bones. Epiphyseal tendons leave markings on bones that look like those left by articular surfaces. These tendons have a prominent zone of fibrocartilage at their attachment site and the deepest part of this is calcified, just as the deepest part of articular hyaline cartilage is calcified. After maceration of the soft tissues, the calcified (fibro) cartilage is left attached to the bone at articular surfaces and at the sites of tendon attachment. In all cases, the tissues separate at the basophilic tidemark between the calcified and uncalcified regions. This tidemark is smooth where there is much overlying uncalcified (fibro) cartilage and it is the smoothness that gives the typical appearance of the dried bone. Blood vessels do not generally traverse the tendon fibrocartilage plugs. Hence the areas are devoid of vascular foramina. The functional significance of tendon fibrocartilage is discussed with particular reference to supraspinatus. It is suggested that the uncalcified fibrocartilage ensures that the tendon fibres do not bend, splay out or become compressed at a hard tissue interface, and are thereby offered some protection from wear and tear. It is also suggested that the fibrocartilage plug of supraspinatus prevents the tendon from rubbing on the head of the humerus. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 PMID:3693113

  1. A biomechanical comparison of tendon-bone interface motion and cyclic loading between single-row, triple-loaded cuff repairs and double-row, suture-tape cuff repairs using biocomposite anchors.

    PubMed

    Barber, F Alan; Drew, Otis R

    2012-09-01

    To compare tendon-bone interface motion and cyclic loading in a single-row, triple-loaded anchor repair with a suture-tape, rip-stop, double-row rotator cuff repair. Using 18 human shoulders from 9 matched cadaveric pairs, we created 2 groups of rotator cuff repairs. Group 1 was a double-row, rip-stop, suture-tape construct. Group 2 was a single-row, triple-loaded construct. Before mechanical testing, the supraspinatus footprint was measured with calipers. A superiorly positioned digital camera optically measured the tendon footprint motion during 60° of humeral internal and external rotation. Specimens were secured at a fixed angle not exceeding 45° in reference to the load. After preloading, each sample was cycled between 10 N and 100 N for 200 cycles at 1 Hz, followed by destructive testing at 33 mm/s. A digital camera with tracking software measured the repair displacement at 100 and 200 cycles. Ultimate load and failure mode for each sample were recorded. The exposed anterior footprint border (6.5% ± 6%) and posterior footprint border (0.9% ± 1.7%) in group 1 were statistically less than the exposed anterior footprint border (30.3% ± 17%) and posterior footprint border (29.8% ± 14%) in group 2 (P = .003 and P < .001, respectively). The maximal internal rotation and external rotation tendon footprint displacements in group 1 (1.6 mm and 1.4 mm, respectively) were less than those in group 2 (both 3.6 mm) (P = .007 and P = .004, respectively). Mean displacement after 100 cycles for group 1 and group 2 was 2.0 mm and 3.2 mm, respectively, and at 200 cycles, mean displacement was 2.5 mm and 4.2 mm, respectively (P = .02). The mean ultimate failure load in group 1 (586 N) was greater than that in group 2 (393 N) (P = .02). The suture-tendon interface was the site of most construct failures. The suture-tape, rip-stop, double-row rotator cuff repair had greater footprint coverage, less rotational footprint displacement, and a greater mean ultimate failure load

  2. Tendon biomechanics and mechanobiology - a mini-review of basic concepts and recent advancements

    PubMed Central

    Wang, James H-C.; Guo, Qianping; Li, Bin

    2011-01-01

    Due to their unique hierarchical structure and composition, tendons possess characteristic biomechanical properties, including high mechanical strength and viscoelasticity, which enable them to carry and transmit mechanical loads (muscular forces) effectively. Tendons are also mechano-responsive by adaptively changing their structure and function in response to altered mechanical loading conditions. In general, mechanical loading at physiological levels is beneficial to tendons, but excessive loading or disuse of tendons is detrimental. This mechano-adaptability is due to the cells present in tendons. Tendon fibroblasts (tenocytes) are the dominant tendon cells responsible for tendon homeostasis and repair. Tendon stem cells (TSCs), which were recently discovered, also play a vital role in tendon maintenance and repair by virtue of their ability to self-renew and differentiate into tenocytes. TSCs may also be responsible for chronic tendon injury, or tendinopathy, by undergoing aberrant differentiation into non-tenocytes in response to excessive mechanical loading. Thus, it is necessary to devise optimal rehabilitation protocols in order to enhance tendon healing while reducing scar tissue formation and tendon adhesions. Moreover, along with scaffolds that can mimic tendon matrix environments and platelet-rich plasma (PRP), which serves as a source of growth factors, TSCs may be the optimal cell type for enhancing repair of injured tendons. PMID:21925835

  3. Contraction dynamics and function of the muscle-tendon complex depend on the muscle fibre-tendon length ratio: a simulation study.

    PubMed

    Mörl, Falk; Siebert, Tobias; Häufle, Daniel

    2016-02-01

    Experimental studies show different muscle-tendon complex (MTC) functions (e.g. motor or spring) depending on the muscle fibre-tendon length ratio. Comparing different MTC of different animals examined experimentally, the extracted MTC functions are biased by, for example, MTC-specific pennation angle and fibre-type distribution or divergent experimental protocols (e.g. influence of temperature or stimulation on MTC force). Thus, a thorough understanding of variation of these inner muscle fibre-tendon length ratios on MTC function is difficult. In this study, we used a hill-type muscle model to simulate MTC. The model consists of a contractile element (CE) simulating muscle fibres, a serial element (SE) as a model for tendon, and a parallel elastic element (PEE) modelling tissue in parallel to the muscle fibres. The simulation examines the impact of length variations of these components on contraction dynamics and MTC function. Ensuring a constant overall length of the MTC by L(MTC) = L(SE) + L(CE), the SE rest length was varied over a broad physiological range from 0.1 to 0.9 MTC length. Five different MTC functions were investigated by simulating typical physiological experiments: the stabilising function with isometric contractions, the motor function with contractions against a weight, the capability of acceleration with contractions against a small inertial mass, the braking function by decelerating a mass, and the spring function with stretch-shortening cycles. The ratio of SE and CE mainly determines the MTC function. MTC with comparably short tendon generates high force and maximal shortening velocity and is able to produce maximal work and power. MTC with long tendon is suitable to store and release a maximum amount of energy. Variation of muscle fibre-tendon ratio yielded two peaks for MTC's force response for short and long SE lengths. Further, maximum work storage capacity of the SE is at long relL(SE,0). Impact of fibre-tendon length ratio on MTC

  4. Storage and release of hydrogen cyanide in a chelicerate (Oribatula tibialis)

    PubMed Central

    Brückner, Adrian; Raspotnig, Günther; Wehner, Katja; Meusinger, Reinhard; Norton, Roy A.; Heethoff, Michael

    2017-01-01

    Cyanogenesis denotes a chemical defensive strategy where hydrogen cyanide (HCN, hydrocyanic or prussic acid) is produced, stored, and released toward an attacking enemy. The high toxicity and volatility of HCN requires both chemical stabilization for storage and prevention of accidental self-poisoning. The few known cyanogenic animals are exclusively mandibulate arthropods (certain myriapods and insects) that store HCN as cyanogenic glycosides, lipids, or cyanohydrins. Here, we show that cyanogenesis has also evolved in the speciose Chelicerata. The oribatid mite Oribatula tibialis uses the cyanogenic aromatic ester mandelonitrile hexanoate (MNH) for HCN storage, which degrades via two different pathways, both of which release HCN. MNH is emitted from exocrine opisthonotal oil glands, which are potent organs for chemical defense in most oribatid mites. PMID:28289203

  5. Dedicated ultrasound speckle tracking to study tendon displacement

    NASA Astrophysics Data System (ADS)

    Korstanje, Jan-Wiebe H.; Selles, Ruud W.; Stam, Henk J.; Hovius, Steven E. R.; Bosch, Johan G.

    2009-02-01

    Ultrasound can be used to study tendon and muscle movement. However, quantization is mostly based on manual tracking of anatomical landmarks such as the musculotendinous junction, limiting the applicability to a small number of muscle-tendon units. The aim of this study is to quantify tendon displacement without employing anatomical landmarks, using dedicated speckle tracking in long B-mode image sequences. We devised a dedicated two-dimensional multikernel block-matching scheme with subpixel accuracy to handle large displacements over long sequences. Images were acquired with a Philips iE33 with a 7 MHz linear array and a VisualSonics Vevo 770 using a 40 MHz mechanical probe. We displaced the flexor digitorum superficialis of two pig cadaver forelegs with three different velocities (4,10 and 16 mm/s) over 3 distances (5, 10, 15 mm). As a reference, we manually determined the total displacement of an injected hyperechogenic bullet in the tendons. We automatically tracked tendon parts with and without markers and compared results to the true displacement. Using the iE33, mean tissue displacement underestimations for the three different velocities were 2.5 +/- 1.0%, 1.7 +/- 1.1% and 0.7 +/- 0.4%. Using the Vevo770, mean tissue displacement underestimations were 0.8 +/- 1.3%, 0.6 +/- 0.3% and 0.6 +/- 0.3%. Marker tracking displacement underestimations were only slightly smaller, showing limited tracking drift for non-marker tendon tissue as well as for markers. This study showed that our dedicated speckle tracking can quantify extensive tendon displacement with physiological velocities without anatomical landmarks with good accuracy for different types of ultrasound configurations. This technique allows tracking of a much larger range of muscle-tendon units than by using anatomical landmarks.

  6. Relationship between chronic pathologies of the supraspinatus tendon and the long head of the biceps tendon: systematic review.

    PubMed

    Redondo-Alonso, Lucía; Chamorro-Moriana, Gema; Jiménez-Rejano, José Jesús; López-Tarrida, Patricio; Ridao-Fernández, Carmen

    2014-11-18

    Chronic supraspinatus tendinopathy is a common clinical problem that causes functional and labor disabilities in the population. It is the most frequent cause of shoulder pain. This pathology may be frequently associated to the affectation of the long head of biceps tendon (LHBT), the main stabilizer of the glenohumeral joint together with the supraspinatus. The main aim of this work is to study the prevalence of lesions in LHBT associated to the chronic pathology of the supraspinatus tendon. A systematic review was carried out between May to July 2013 in the electronic databases: CINAHL, WOK, Medline, Scopus, PEDro, IME (CSIC) and Dialnet. The keywords used were: 1) in English: chronic, supraspinatus "long head of the biceps tendon", biceps, rotator cuff, tendinosis, tendinopathy, evaluation, examination; 2) in Spanish: supraespinoso, biceps, tendinopatía. Inclusion criteria of the articles included subjects with a previously diagnosed chronic pathology of rotator cuff (RC) without previous surgery or any other pathologies of the shoulder complex. The total number of articles included in the study were five. The results show an epidemiological relationship between both tendons. The age of the subjects included in the review was between 35 and 80 years, and some of the studies seem to indicate that the tendinopathy is more frequent in men than in women. The sample size of the studies varies according to the design, the highest being composed of 229 subjects, and the minimum of 28. Not all the articles selected specify the diagnostic testing, though the ones most normally used are arthroscopy, ultrasound, magnetic resonance imaging and assessment tests. The percentage of associated lesions of LHBT and supraspinatus tendon is between 78.5% and 22%, with a major prevalence in the studies with a smaller sample. The review of literature corroborates an association between the chronic pathology of the supraspinatus tendon and LHBT due to the epidemiological data. In

  7. Preinjury and postinjury running analysis along with measurements of strength and tendon length in a patient with a surgically repaired Achilles tendon rupture.

    PubMed

    Silbernagel, Karin Grävare; Willy, Richard; Davis, Irene

    2012-06-01

    Case report. The Achilles tendon is the most frequently ruptured tendon, and the incidence of Achilles tendon rupture has increased in the last decade. The rupture generally occurs without any preceding warning signs, and therefore preinjury data are seldom available. This case represents a unique opportunity to compare preinjury running mechanics with postinjury evaluation in a patient with an Achilles tendon rupture. A 23-year-old female sustained a right complete Achilles tendon rupture while playing soccer. Running mechanics data were collected preinjury, as she was a healthy participant in a study on running analysis. In addition, patient-reported symptoms, physical activity level, strength, ankle range of motion, heel-rise ability, Achilles tendon length, and running kinetics were evaluated 1 year after surgical repair. During running, greater ankle dorsiflexion and eversion and rearfoot abduction were noted on the involved side postinjury when compared to preinjury data. In addition, postinjury, the magnitude of all kinetics data was lower on the involved limb when compared to the uninvolved limb. The involved side displayed differences in strength, ankle range of motion, heel rise, and tendon length when compared to the uninvolved side 1 year after injury. Despite a return to normal running routine and reports of only minor limitations with running, considerable changes were noted in running biomechanics 1 year after injury. Calf muscle weakness and Achilles tendon elongation were also found when comparing the involved and uninvolved sides.

  8. System and Method for Tensioning a Robotically Actuated Tendon

    NASA Technical Reports Server (NTRS)

    Reiland, Matthew J. (Inventor); Diftler, Myron A. (Inventor)

    2013-01-01

    A tendon tensioning system includes a tendon having a proximal end and a distal end, an actuator, and a motor controller. The actuator may include a drive screw and a motor, and may be coupled with the proximal end of the tendon and configured to apply a tension through the tendon in response to an electrical current. The motor controller may be electrically coupled with the actuator, and configured to provide an electrical current having a first amplitude to the actuator until a stall tension is achieved through the tendon; provide a pulse current to the actuator following the achievement of the stall tension, where the amplitude of the pulse current is greater than the first amplitude, and return the motor to a steady state holding current following the conclusion of the pulse current.

  9. Cellular therapy in bone-tendon interface regeneration

    PubMed Central

    Rothrauff, Benjamin B; Tuan, Rocky S

    2014-01-01

    The intrasynovial bone-tendon interface is a gradual transition from soft tissue to bone, with two intervening zones of uncalcified and calcified fibrocartilage. Following injury, the native anatomy is not restored, resulting in inferior mechanical properties and an increased risk of re-injury. Recent in vivo studies provide evidence of improved healing when surgical repair of the bone-tendon interface is augmented with cells capable of undergoing chondrogenesis. In particular, cellular therapy in bone-tendon healing can promote fibrocartilage formation and associated improvements in mechanical properties. Despite these promising results in animal models, cellular therapy in human patients remains largely unexplored. This review highlights the development and structure-function relationship of normal bone-tendon insertions. The natural healing response to injury is discussed, with subsequent review of recent research on cellular approaches for improved healing. Finally, opportunities for translating in vivo findings into clinical practice are identified. PMID:24326955

  10. Pleiotropic roles of the matricellular protein Sparc in tendon maturation and ageing

    PubMed Central

    Gehwolf, Renate; Wagner, Andrea; Lehner, Christine; Bradshaw, Amy D.; Scharler, Cornelia; Niestrawska, Justyna A.; Holzapfel, Gerhard A.; Bauer, Hans-Christian; Tempfer, Herbert; Traweger, Andreas

    2016-01-01

    Acute and chronic tendinopathies remain clinically challenging and tendons are predisposed to degeneration or injury with age. Despite the high prevalence of tendon disease in the elderly, our current understanding of the mechanisms underlying the age-dependent deterioration of tendon function remains very limited. Here, we show that Secreted protein acidic and rich in cysteine (Sparc) expression significantly decreases in healthy-aged mouse Achilles tendons. Loss of Sparc results in tendon collagen fibrillogenesis defects and Sparc−/− tendons are less able to withstand force in comparison with their respective wild type counterparts. On the cellular level, Sparc-null and healthy-aged tendon-derived cells exhibited a more contracted phenotype and an altered actin cytoskeleton. Additionally, an elevated expression of the adipogenic marker genes PPARγ and Cebpα with a concomitant increase in lipid deposits in aged and Sparc−/− tendons was observed. In summary, we propose that Sparc levels in tendons are critical for proper collagen fibril maturation and its age-related decrease, together with a change in ECM properties favors lipid accretion in tendons. PMID:27586416

  11. Peroneal Tendon Reconstruction and Coverage for Treatment of Septic Peroneal Tenosynovitis: A Devastating Complication of Lateral Ankle Ligament Reconstruction With a Tendon Allograft.

    PubMed

    Schade, Valerie L; Harsha, Wayne; Rodman, Caitlin; Roukis, Thomas S

    2016-01-01

    Septic peroneal tenosynovitis is a rare and significant challenge. A search of peer-reviewed published studies revealed only 5 case reports to guide treatment, none of which resulted in significant loss of both peroneal tendons necessitating reconstruction. No clear guidance is available regarding how to provide reliable reconstruction of both peroneal tendons after a significant loss secondary to septic tenosynovitis. In the present report, we describe the case of a young, active-duty soldier who underwent lateral ankle ligament reconstruction with a tendon allograft whose postoperative course was complicated by septic peroneal tenosynovitis resulting in significant loss of both peroneal tendons. Reconstruction was achieved in a staged fashion with the use of silicone rods and external fixation to maintain physiologic tension and preserve peroneal tendon function, followed by reconstruction of both peroneal tendons and the superior peroneal retinaculum with a tensor fascia lata autograft. Soft tissue coverage was obtained with an anterolateral thigh free tissue transfer and a split-thickness skin graft. The patient returned to full activity as an active-duty soldier with minimal pain and no instability of the right lower extremity. The muscle strength of both peroneal tendons remained at 5 of 5, and no objective findings of ankle instability were seen at 3.5 years postoperatively. Published by Elsevier Inc.

  12. Differences between the Cell Populations from the Peritenon and the Tendon Core with Regard to Their Potential Implication in Tendon Repair

    PubMed Central

    Cadby, Jennifer A.; Buehler, Evelyne; Godbout, Charles; van Weeren, P. René; Snedeker, Jess G.

    2014-01-01

    The role of intrinsic and extrinsic healing in injured tendons is still debated. In this study, we characterized cell plasticity, proliferative capacity, and migration characteristics as proxy measures of healing potential in cells derived from the peritenon (extrinsic healing) and compared these to cells from the tendon core (intrinsic healing). Both cell populations were extracted from horse superficial digital flexor tendon and characterized for tenogenic and matrix remodeling markers as well as for rates of migration and replication. Furthermore, colony-forming unit assays, multipotency assays, and real-time quantitative polymerase chain reaction analyses of markers of osteogenic and adipogenic differentiation after culture in induction media were performed. Finally, cellular capacity for differentiation towards a myofibroblastic phenotype was assessed. Our results demonstrate that both tendon- and peritenon-derived cell populations are capable of adipogenic and osteogenic differentiation, with higher expression of progenitor cell markers in peritenon cells. Cells from the peritenon also migrated faster, replicate more quickly, and show higher differentiation potential toward a myofibroblastic phenotype when compared to cells from the tendon core. Based on these data, we suggest that cells from the peritenon have substantial potential to influence tendon-healing outcome, warranting further scrutiny of their role. PMID:24651449

  13. Different Achilles Tendon Pathologies Show Distinct Histological and Molecular Characteristics

    PubMed Central

    Minkwitz, Susann; Schmock, Aysha; Bormann, Nicole; Kurtoglu, Alper; Tsitsilonis, Serafeim; Manegold, Sebastian

    2018-01-01

    Reasons for the development of chronic tendon pathologies are still under debate and more basic knowledge is needed about the different diseases. The aim of the present study was therefore to characterize different acute and chronic Achilles tendon disorders. Achilles tendon samples from patients with chronic tendinopathy (n = 7), chronic ruptures (n = 6), acute ruptures (n = 13), and intact tendons (n = 4) were analyzed. The histological score investigating pathological changes was significantly increased in tendinopathy and chronic ruptures compared to acute ruptures. Inflammatory infiltration was detected by immunohistochemistry in all tendon pathology groups, but was significantly lower in tendinopathy compared to chronic ruptures. Quantitative real-time PCR (qRT-PCR) analysis revealed significantly altered expression of genes related to collagens and matrix modeling/remodeling (matrix metalloproteinases, tissue inhibitors of metalloproteinases) in tendinopathy and chronic ruptures compared to intact tendons and/or acute ruptures. In all three tendon pathology groups markers of inflammation (interleukin (IL) 1β, tumor necrosis factor α, IL6, IL10, IL33, soluble ST2, transforming growth factor β1, cyclooxygenase 2), inflammatory cells (cluster of differentaition (CD) 3, CD68, CD80, CD206), fat metabolism (fatty acid binding protein 4, peroxisome proliferator-activated receptor γ, CCAAT/enhancer-binding protein α, adiponectin), and innervation (protein gene product 9.5, growth associated protein 43, macrophage migration inhibitory factor) were detectable, but only in acute ruptures significantly regulated compared to intact tendons. The study gives an insight into structural and molecular changes of pathological processes in tendons and might be used to identify targets for future therapy of tendon pathologies. PMID:29385715

  14. Landing strategies of athletes with an asymptomatic patellar tendon abnormality.

    PubMed

    Edwards, Suzi; Steele, Julie R; McGhee, Deirdre E; Beattie, Sue; Purdam, Craig; Cook, Jill L

    2010-11-01

    Risk factors associated with a clinical presentation of patellar tendinopathy are patellar tendon ultrasonographic abnormality (PTA) and excessive loading. It remains unknown whether characteristics of an athlete's landing technique contribute to this excessive patellar tendon loading. This study investigated whether asymptomatic athletes with and without PTA had different landing strategies and hypothesized that asymptomatic athletes with a PTA would create higher patellar tendon loading and a different lower-limb landing strategy compared with athletes with normal patellar tendons. Seven athletes with no previous history or clinical signs of patellar tendon injury with a PTA were matched to athletes with normal patellar tendons (controls). Participants performed five successful trials of a stop-jump task, which involved a simultaneous two-foot horizontal and then vertical landing. During each trial, the participants' ground reaction forces and lower-limb electromyographic data were recorded, the three-dimensional kinematics measured, and the peak patellar tendon force calculated by dividing the net knee joint moment by the patellar tendon moment arm. Significant between-group differences in landing technique were mostly observed during the horizontal landing phase. Participants with a PTA created similar patellar tendon loading to the controls, but with altered sequencing, by landing with significantly greater knee flexion and extending their hips while the controls flexed their hips as they landed, reflecting a different muscle recruitment order compared with the PTA group. The crucial part in the development of PTA and, in turn, patellar tendinopathy may not be the magnitude of the patellar tendon load but rather the loading patterns. This research provides clinicians with important landing assessment criteria against which to identify athletes at risk of developing patellar tendinopathy.

  15. Intracapsular origin of the long head of the biceps tendon with glenoid avulsion of the glenohumeral ligaments.

    PubMed

    Parikh, Shital N; Bonnaig, Nicolas; Zbojniewicz, Andrew

    2011-11-09

    An 18-year-old woman presented with a history of recurrent glenohumeral dislocations involving her right dominant shoulder. Physical examination suggested physiologic hyperlaxity and anterior instability. Magnetic resonance arthrography demonstrated an anomalous intracapsular origin of the long head of the biceps tendon (LHBT), with normal-appearing LHBT in the intertubercular groove. Diagnostic arthroscopy confirmed the absence of the LHBT attachment on the superior labrum. Instead, the LHBT originated from the capsule of the shoulder joint. Diagnostic arthroscopy also revealed glenoid avulsion of the glenohumeral ligaments (GAGL) lesion as a tear in the anterior-inferior capsule near its insertion on the glenoid and labrum. An arthroscopic anterior capsulolabral repair was performed with rotator interval closure by imbrication of superior and middle glenohumeral ligaments. A retrospective review of the magnetic resonance arthrogram identified irregularity and interposition of contrast between the capsule and the anterior-inferior labrum that was reproduced in the abduction-external rotation view corresponding with the GAGL lesion seen at arthroscopy. At 12 months postoperatively, the patient demonstrated full range of motion and no signs of instability. This case report helps to raise awareness about 2 rare shoulder lesions: the anomalous origin of LHBT and the GAGL lesion. Diagnosing such lesions on preoperative magnetic resonance imaging may aid in operative planning and avoid unexpected intraoperative findings. Copyright 2011, SLACK Incorporated.

  16. Effect of Intraoperative Platelet-Rich Plasma Treatment on Postoperative Donor Site Knee Pain in Patellar Tendon Autograft Anterior Cruciate Ligament Reconstruction: A Double-Blind Randomized Controlled Trial.

    PubMed

    Walters, Brian L; Porter, David A; Hobart, Sarah J; Bedford, Benjamin B; Hogan, Daniel E; McHugh, Malachy M; Klein, Devon A; Harousseau, Kendall; Nicholas, Stephen J

    2018-05-01

    Donor site morbidity in the form of anterior knee pain is a frequent complication after bone-patellar tendon-bone (BPTB) autograft anterior cruciate ligament (ACL) reconstruction. Hypothesis/Purpose: The purpose was to examine the effect of the intraoperative administration of platelet-rich plasma (PRP) on postoperative kneeling pain. It was hypothesized that PRP treatment would reduce knee pain. Randomized controlled trial; Level of evidence, 2. Fifty patients (mean ± SD age, 30 ± 12 years) undergoing BPTB ACL autograft reconstruction were randomized to the PRP (n = 27) or sham (n = 23) treatment. In either case, 10 mL of venous blood was drawn before the induction of anesthesia and either discarded (sham) or processed (PRP) for preparation of a PRP gel to be later mixed with donor site bone chips and inserted into the patellar defect. At 12 weeks, 6 months, 1 year, and 2 years after surgery, patients completed International Knee Documentation Committee (IKDC) forms and visual analog scale pain scores for activities of daily living and kneeling. Healing indices at the donor site were assessed by routine noncontrast magnetic resonance imaging (MRI) at 6 months. Mixed-model analysis of variance was used to assess the effect of PRP on patient symptoms and MRI indices of donor site healing, as measured by the width of the donor site defect. Kneeling pain, pain with activities of daily living, and IKDC scores were not different between treatment groups at any of the time intervals ( P = .08-.83). Kneeling pain improved from 12 weeks to 6 months and from 1 to 2 years ( P < .05). IKDC scores improved substantially from 12 weeks to 6 months ( P < .001) and continued to improve to 2 years (PRP, 86 ± 19; sham, 89 ± 10). MRI indices of donor site healing were not different between treatment groups ( P = .53-.90). Whether randomized to receive PRP in their patellar defect or not, patients continued to have similar levels of kneeling pain and patellar defect sizes after

  17. Proximal Biceps Tendonitis

    MedlinePlus

    ... teens, biceps tendonitis is usually an overuse injury. Baseball pitchers, swimmers, tennis players, and people who have ... But if you swim or play tennis or baseball, that might not be an option! If your ...

  18. Extensor Tendon Injuries

    MedlinePlus

    ... the Hand. Find a hand surgeon near you. Videos Figures Figure 1 - Extensor tendons, located on the ... or "in." Also, avoid using media types like "video," "article," and "picture." Tip 4: Your results can ...

  19. Tendon Transfer Surgery

    MedlinePlus

    ... Transfer Surgery Find a hand surgeon near you. Videos Figures Figure 2: Example of Tendon Transfer surgery ... or "in." Also, avoid using media types like "video," "article," and "picture." Tip 4: Your results can ...

  20. Flexor Tendon Injuries

    MedlinePlus

    ... the Hand. Find a hand surgeon near you. Videos Figures Figure 1 -The tendons of the hand ... or "in." Also, avoid using media types like "video," "article," and "picture." Tip 4: Your results can ...

  1. The effect of muscle excursion on muscle recovery after tendon repair in a neglected tendon injury: a study in rabbit soleus muscles.

    PubMed

    Jeon, Suk Ha; Chung, Moon Sang; Baek, Goo Hyun; Lee, Young Ho; Gong, Hyun Sik

    2011-01-01

    We attempted to determine whether muscle excursion observed during operation can be a prognostic indicator of muscle recovery after delayed tendon repair in a rabbit soleus model. Eighteen rabbits underwent tenotomy of the soleus muscles bilaterally and were divided into three groups according to the period from tenotomy to repair. The tendons of each group were repaired 2, 4, and 6 weeks after tenotomy. The excursion of each soleus muscle was measured at the time of tenotomy (baseline), at 2, 4, 6 weeks after tenotomy, and 8 weeks after tendon repair. The amount of muscle recovery after tendon repair in terms of muscle excursion independently depended on the timing of repair and on the muscle excursion observed during repair. The regression model predicted that the muscle excursion recovered on average by 0.6% as the muscle excursion at the time of repair increased by 1% after adjusting for the timing of repair. This study suggests that measuring the muscle excursion during tendon repair may help physicians estimate the potential of muscle recovery in cases of delayed tendon repair. Copyright © 2010 Orthopaedic Research Society.

  2. Quantitative US Elastography Can Be Used to Quantify Mechanical and Histologic Tendon Healing in a Rabbit Model of Achilles Tendon Transection.

    PubMed

    Yamamoto, Yohei; Yamaguchi, Satoshi; Sasho, Takahisa; Fukawa, Taisuke; Akatsu, Yorikazu; Akagi, Ryuichiro; Yamaguchi, Tadashi; Takahashi, Kenji; Nagashima, Kengo; Takahashi, Kazuhisa

    2017-05-01

    Purpose To determine the time-dependent change in strain ratios (SRs) at the healing site of an Achilles tendon rupture in a rabbit model of tendon transection and to assess the correlation between SRs and the mechanical and histologic properties of the healing tissue. Materials and Methods Experimental methods were approved by the institutional animal care and use committee. The Achilles tendons of 24 New Zealand white rabbits (48 limbs) were surgically transected. The SRs of Achilles tendons were calculated by using compression-based quantitative ultrasonographic elastography measurements obtained 2, 4, 8, and 12 weeks after transection. After in vivo elastography, the left Achilles tendon was harvested for mechanical testing of ultimate load, ultimate stress, elastic modulus, and linear stiffness, and the right tendons were harvested for tissue histologic analysis with the Bonar scale. Time-dependent changes in SRs, mechanical parameters, and Bonar scale scores were evaluated by using repeated-measures analysis of variance. The correlation between SRs and each measured variable was evaluated by using the Spearman rank correlation coefficient. Results Mean SRs and Bonar scale values decreased as a function of time after transection, whereas mechanical parameters increased (P < .001). SR correlated with ultimate stress (ρ = 0.68, P <.001,) elastic modulus (ρ = 0.74, P <.001), and the Bonar scale (ρ = 0.87, P <.001). Conclusion Quantitative elastography could be a useful method with which to evaluate mechanical and histologic properties of the healing tendon. © RSNA, 2017 Online supplemental material is available for this article.

  3. Age-related differences in muscle activity patterns during walking in healthy individuals.

    PubMed

    Van Criekinge, Tamaya; Saeys, Wim; Hallemans, Ann; Van de Walle, Patricia; Vereeck, Luc; De Hertogh, Willem; Truijen, Steven

    2018-05-26

    To examine how muscle activity over the entire gait cycle changes with increasing age. Electromyography data of the erector spinae, rectus femoris, vastus lateralis, biceps femoris, tibialis anterior and gastrocnemius muscles were collected by an instrumented gait analysis during over ground walking in healthy adults aged between 20 and 89 years. Participants were categorized per decade (n = 105, 15 per decade, decades 3-9). Normalized integrated linear envelopes of the electromyographic signal were calculated for one stride. A one way ANOVA using spm1d statistics explored the differences between age groups, followed by a post hoc analysis. While initiation of decline commenced at the age of 60 for erector spinae and tibialis anterior, age-related changes are most pronounced after the age of 80. Concerning timing of muscle activity, subjects in decade 7-9 had prolonged activity and/or early activity of the erector spinae, vastus lateralis, biceps femoris, tibialis anterior and gastrocnemius compared to other decades. Regarding amplitude of muscle activity, decreased peak amplitudes of the erector spinae, rectus femoris, vastus lateralis and gastrocnemius were observed in decades 7-9 compared to other decades. Both timing and amplitude of muscle activation patterns need to be considered to understand the aging process. Regarding the erector spinae, tibialis anterior and vastus lateralis, a decrease in muscle activation coincides with prolonged activity, compared to the gastrocnemius where decreased muscle activation is associated with early activation. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Rolled Tendon Allograft Interposition Arthroplasty for Salvage Surgery of the Hallux Metatarsophalangeal Joint.

    PubMed

    Thomas, Danielle; Thordarson, David

    2018-04-01

    Hallux rigidus is a common osteoarthritic disease of the first metatarsophalangeal joint (MTPJ). Few salvage treatment options exist that preserve motion for patients who have failed an initial procedure and who are not amenable to fusion, typically patients who are active or who would like to wear high heels. Allograft tendon interpositional arthroplasty is an unconventional salvage treatment option that may preserve motion and prevent bone loss. A retrospective chart review is reported of 19 patients who failed previous procedures and refused fusion who underwent allograft tendon interpositional arthroplasty of the hallux MTPJ by a single surgeon between 2012 and 2015. Outcomes included the American Orthopaedic Foot & Ankle Society (AOFAS) hallux metatarsophalangeal-interphalangeal scale assessment as well as measurement of apparent joint space on anterior to posterior and lateral views. The cumulative average AOFAS score for all patients was 68.5 preoperatively and 74.1 postoperatively. The average AOFAS pain subscore was 24.7 preoperatively and 26.8 postoperatively (SD = 7.7 and 13.8, respectively). Radiographically, patients had an increase in apparent joint space from pre- to postoperatively, most notable on the lateral view (0.6 to 4.7 mm; SD = 0.7 and 3.2 mm). Five patients required a second operative procedure, for an overall 26% reoperation rate. One patient underwent hallux MTPJ fusion after the interpositional arthroplasty. An additional 4 patients (21%) had symptoms requiring a steroid injection, and another 3 patients (16%) were recommended to undergo a revision procedure based on their symptoms. Rolled allograft tendon interposition arthroplasty performed poorly as a salvage strategy for failed previous hallux MTPJ surgery for hallux rigidus because of a high rate of complication and minimal benefits. The senior author has abandoned the technique. Level IV, retrospective case series.

  5. Changes in bacterial gut community of Reticulitermes flavipes (Kollar) and Reticulitermes tibialis Banks after feeding on termiticidal bait material

    Treesearch

    Rachel A. Arango; Frederick Green III; Kenneth F. Raffa

    2014-01-01

    In this study, 454-pyrosequencing was used to evaluate the effect of two termiticidal baits, hexaflumuron and diflubenzuron, on the bacterial gut community in two Reticulitermes flavipes colonies and one Reticulitermes tibialis colony. Results showed two bacterial groups to be most abundant in the gut, the Bacteroidetes and...

  6. HGF Mediates the Anti-inflammatory Effects of PRP on Injured Tendons

    PubMed Central

    Zhang, Jianying; Middleton, Kellie K.; Fu, Freddie H.; Im, Hee-Jeong; Wang, James H-C.

    2013-01-01

    Platelet-rich plasma (PRP) containing hepatocyte growth factor (HGF) and other growth factors are widely used in orthopaedic/sports medicine to repair injured tendons. While PRP treatment is reported to decrease pain in patients with tendon injury, the mechanism of this effect is not clear. Tendon pain is often associated with tendon inflammation, and HGF is known to protect tissues from inflammatory damages. Therefore, we hypothesized that HGF in PRP causes the anti-inflammatory effects. To test this hypothesis, we performed in vitro experiments on rabbit tendon cells and in vivo experiments on a mouse Achilles tendon injury model. We found that addition of PRP or HGF decreased gene expression of COX-1, COX-2, and mPGES-1, induced by the treatment of tendon cells in vitro with IL-1β. Further, the treatment of tendon cell cultures with HGF antibodies reduced the suppressive effects of PRP or HGF on IL-1β-induced COX-1, COX-2, and mPGES-1 gene expressions. Treatment with PRP or HGF almost completely blocked the cellular production of PGE2 and the expression of COX proteins. Finally, injection of PRP or HGF into wounded mouse Achilles tendons in vivo decreased PGE2 production in the tendinous tissues. Injection of platelet-poor plasma (PPP) however, did not reduce PGE2 levels in the wounded tendons, but the injection of HGF antibody inhibited the effects of PRP and HGF. Further, injection of PRP or HGF also decreased COX-1 and COX-2 proteins. These results indicate that PRP exerts anti-inflammatory effects on injured tendons through HGF. This study provides basic scientific evidence to support the use of PRP to treat injured tendons because PRP can reduce inflammation and thereby reduce the associated pain caused by high levels of PGE2. PMID:23840657

  7. 21 CFR 888.3025 - Passive tendon prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Passive tendon prosthesis. 888.3025 Section 888.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3025 Passive tendon prosthesis. (a...

  8. 21 CFR 888.3025 - Passive tendon prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Passive tendon prosthesis. 888.3025 Section 888.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3025 Passive tendon prosthesis. (a...

  9. 21 CFR 888.3025 - Passive tendon prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Passive tendon prosthesis. 888.3025 Section 888.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3025 Passive tendon prosthesis. (a...

  10. The role of ultrasound in the management of flexor tendon injuries.

    PubMed

    Jeyapalan, K; Bisson, M A; Dias, J J; Griffin, Y; Bhatt, R

    2008-08-01

    The use of ultrasound scanning to establish tendon pathologies was assessed retrospectively in 17 patients in 18 digits. The ultrasound scan demonstrated four patterns: (1) normal intact tendons in four, (2) ruptured tendons in three, (3) tendons in continuity but attenuated in five and (4) tendons in continuity but thickened with fibrosis and decreased movement representing adhesions in five patients. Surgery was undertaken in only three cases, confirming the ultrasound diagnosis in two. Surgery was offered to all three patients with ruptures but was declined by two. Ultrasound imaging helped to avoid surgery in 14 cases by excluding flexor tendon re-ruptures. This allowed on-going mobilisation, leading to recovery of function.

  11. Distal Triceps Tendon Injuries.

    PubMed

    Keener, Jay D; Sethi, Paul M

    2015-11-01

    Acute triceps ruptures are an uncommon entity, occurring mainly in athletes, weight lifters (especially those taking anabolic steroids), and following elbow trauma. Accurate diagnosis is made clinically, although MRI may aid in confirmation and surgical planning. Acute ruptures are classified on an anatomic basis based on tear location and the degree of tendon involvement. Most complete tears are treated surgically in medically fit patients. Partial-thickness tears are managed according to the tear severity, functional demands, and response to conservative treatment. We favor an anatomic footprint repair of the triceps to provide optimal tendon to bone healing and, ultimately, functional outcome. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Quadriceps Tendon Autograft Medial Patellofemoral Ligament Reconstruction.

    PubMed

    Fink, Christian; Steensen, Robert; Gföller, Peter; Lawton, Robert

    2018-06-01

    Critically evaluate the published literature related to quadriceps tendon (QT) medial patellofemoral ligament (MPFL) reconstruction. Hamstring tendon (HT) MPFL reconstruction techniques have been shown to successfully restore patella stability, but complications including patella fracture are reported. Quadriceps tendon (QT) reconstruction techniques with an intact graft pedicle on the patella side have the advantage that patella bone tunnel drilling and fixation are no longer needed, reducing risk of patella fracture. Several QT MPFL reconstruction techniques, including minimally invasive surgical (MIS) approaches, have been published with promising clinical results and fewer complications than with HT techniques. Parallel laboratory studies have shown macroscopic anatomy and biomechanical properties of QT are more similar to native MPFL than hamstring (HS) HT, suggesting QT may more accurately restore native joint kinematics. Quadriceps tendon MPFL reconstruction, via both open and MIS techniques, have promising clinical results and offer valuable alternatives to HS grafts for primary and revision MPFL reconstruction in both children and adults.

  13. Effects of celecoxib on proliferation and tenocytic differentiation of tendon-derived stem cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Kairui; Zhang, Sheng; Li, Qianqian

    Highlights: • Celecoxib has no effects on TDSCs cell proliferation in various concentrations. • Celecoxib reduced mRNAs levels of tendon associated transcription factor. • Celecoxib reduced mRNAs levels of main tendon associated collagen. • Celecoxib reduced mRNAs levels of tendon associated molecules. - Abstract: NSAIDs are often ingested to reduce the pain and improve regeneration of tendon after tendon injury. Although the effects of NSAIDs in tendon healing have been reported, the data and conclusions are not consistent. Recently, tendon-derived stem cells (TDSCs) have been isolated from tendon tissues and has been suggested involved in tendon repair. Our study aimsmore » to determine the effects of COX-2 inhibitor (celecoxib) on the proliferation and tenocytic differentiation of TDSCs. TDSCs were isolated from mice Achilles tendon and exposed to celecoxib. Cell proliferation rate was investigated at various concentrations (0.1, 1, 10 and 100 μg/ml) of celecoxib by using hemocytometer. The mRNA expression of tendon associated transcription factors, tendon associated collagens and tendon associated molecules were determined by reverse transcription-polymerase chain reaction. The protein expression of Collagen I, Collagen III, Scleraxis and Tenomodulin were determined by Western blotting. The results showed that celecoxib has no effects on TDSCs cell proliferation in various concentrations (p > 0.05). The levels of most tendon associated transcription factors, tendon associated collagens and tendon associated molecules genes expression were significantly decreased in celecoxib (10 μg/ml) treated group (p < 0.05). Collagen I, Collagen III, Scleraxis and Tenomodulin protein expression were also significantly decreased in celecoxib (10 μg/ml) treated group (p < 0.05). In conclusion, celecoxib inhibits tenocytic differentiation of tendon-derived stem cells but has no effects on cell proliferation.« less

  14. Endoscopy-assisted percutaneous repair of acute Achilles tendon tears.

    PubMed

    Chiu, Chih-Hao; Yeh, Wen-Lin; Tsai, Min-Chien; Chang, Shih-Sheng; Hsu, Kuo-Yao; Chan, Yi-Sheng

    2013-08-01

    We developed a technique for endoscopy-assisted percutaneous repair of acute Achilles tendon tears. Nineteen patients with acute Achilles tendon tears were prospectively recruited into the study. All patients (18 male, 1 female) had sports-related injuries. Preoperative diagnosis was made from patient history, physical examination, and sonography. The average patient age was 38.7 years, and follow-up averaged 24 months. All patients received endoscopy-assisted percutaneous Achilles tendon repair with modified Bunnell sutures passed by bird beak and No. 5 Ethibond under direct visualization using 4.0-mm arthroscopy. Results were evaluated by physical examination, sonography, and magnetic resonance imaging (MRI). All 19 patients achieved tendon healing. All patients were evaluated by sonography, and the tendons of 16 patients were imaged using MRI to evaluate the extent of healing. Final dorsiflexion was 16 degrees and plantar flexion 26 degrees, and 95% of the patients (18/19) returned to their previous level of sporting activity. One patient developed a superficial infection, and 2 patients had postoperative sural nerve injury with numbness for 1 month. There were no other major complications. Endoscopy-assisted percutaneous repair of the Achilles tendon allowed good tendon healing and return to sports at 6 months. Sural nerve injury during surgery was a potential complication of this procedure. Level IV, retrospective case series.

  15. Similar Outcomes After Osteochondral Allograft Transplantation in Anterior Cruciate Ligament-Intact and -Reconstructed Knees: A Comparative Matched-Group Analysis With Minimum 2-Year Follow-Up.

    PubMed

    Wang, Dean; Eliasberg, Claire D; Wang, Tim; Fader, Ryan R; Coxe, Francesca R; Pais, Mollyann D; Williams, Riley J

    2017-12-01

    To compare failure rates and clinical outcomes of osteochondral allograft transplantation (OCA) in anterior cruciate ligament (ACL)-intact versus ACL-reconstructed knees at midterm follow-up. After a priori power analysis, a prospective registry of patients treated with OCA for focal chondral lesions ≥2 cm 2 in size with minimum 2-year follow-up was used to match ACL-reconstructed knees with ACL-intact knees by age, sex, and primary chondral defect location. Exclusion criteria included meniscus transplantation, realignment osteotomy, or other ligamentous injury. Complications, reoperations, and patient responses to validated outcome measures were reviewed. Failure was defined by any procedure involving allograft removal/revision or conversion to arthroplasty. Kaplan-Meier analysis and multivariate Cox regression were performed to evaluate the association of ACL reconstruction (ACLR) with failure. A total of 50 ACL-intact and 25 ACL-reconstructed (18 prior, 7 concomitant) OCA patients were analyzed. The mean age was 36.2 years (range, 14-62 years). Mean follow-up was 3.9 years (range, 2-14 years). Patient demographics and chondral lesion characteristics were similar between groups. ACL-reconstructed patients averaged 2.2 ± 1.9 prior surgeries on the ipsilateral knee compared with 1.4 ± 1.4 surgeries for ACL-intact patients (P = .014). Grafts used for the last ACLR included bone-patellar tendon-bone autograft, hamstring autograft, Achilles tendon allograft, and tibialis allograft (data available for only 11 of 25 patients). At final follow-up, 22% of ACL-intact and 32% of ACL-reconstructed patients had undergone reoperation. OCA survivorship was 90% and 96% at 2 years and 79% and 85% at 5 years in ACL-intact and ACL-reconstructed patients, respectively (P = .774). ACLR was not independently associated with failure. Both groups demonstrated clinically significant improvements in the Short Form-36 pain and physical functioning, International Knee

  16. The Achilles Tendon in Healthy Subjects: An Anthropometric and Ultrasound Mapping Study.

    PubMed

    Patel, Nick N; Labib, Sameh A

    Ultrasonography is an inexpensive, fast, and reliable imaging technique widely used to assess the Achilles tendon. Although significant data exists regarding pathologic tendon changes, ultrasound data from healthy individuals are more limited. We aimed to better characterize ultrasound Achilles tendon measurements in healthy individuals and identify important correlating factors. The information collected included patient demographics, body habitus, activity level, foot dominance, and resting ankle angle. Ultrasound analysis was performed bilaterally on the Achilles tendons of 50 subjects using a high-frequency transducer to measure tendon width, thickness, cross-sectional area, and length. Males had a significantly larger mean tendon length, width, thickness, and cross-sectional area. No statistically significant difference was found in any tendon dimension between the white and black participants. Similarly, no difference was found in any tendon parameter when comparing right versus left leg dominance. Healthy subjects had a mean ankle resting angle of 45.1° ± 24° with no statistically significant difference between right and left ankles. Considering all individuals, each tendon parameter (tendon length, width, thickness, and cross-sectional area) correlated positively with subject height, weight, tibia length, and foot size. Only the Achilles cross-sectional area correlated significantly with the activity level. The resting angle of the ankle correlated positively with both tendon length and thickness. In conclusion, we found significant variations in Achilles tendon anatomy in the healthy adult population. We have thoroughly characterized significant correlations between healthy tendon dimensions and various body habitus, activity levels, and ankle parameters. Greater knowledge of the normal Achilles tendon anatomy and characterization of its variations in the healthy population will potentially allow for better pathologic diagnosis and surgical repair

  17. Achilles tendon shape and echogenicity on ultrasound among active badminton players.

    PubMed

    Malliaras, P; Voss, C; Garau, G; Richards, P; Maffulli, N

    2012-04-01

    The relationship between Achilles tendon ultrasound abnormalities, including a spindle shape and heterogeneous echogenicity, is unclear. This study investigated the relationship between these abnormalities, tendon thickness, Doppler flow and pain. Sixty-one badminton players (122 tendons, 36 men, and 25 women) were recruited. Achilles tendon thickness, shape (spindle, parallel), echogenicity (heterogeneous, homogeneous) and Doppler flow (present or absent) were measured bilaterally with ultrasound. Achilles tendon pain (during or after activity over the last week) and pain and function [Victorian Institute of Sport Achilles Assessment (VISA-A)] were measured. Sixty-eight (56%) tendons were parallel with homogeneous echogenicity (normal), 22 (18%) were spindle shaped with homogeneous echogenicity, 16 (13%) were parallel with heterogeneous echogenicity and 16 (13%) were spindle shaped with heterogeneous echogenicity. Spindle shape was associated with self-reported pain (P<0.05). Heterogeneous echogenicity was associated with lower VISA-A scores than normal tendon (P<0.05). There was an ordinal relationship between normal tendon, parallel and heterogeneous and spindle shaped and heterogeneous tendons with regard to increasing thickness and likelihood of Doppler flow. Heterogeneous echogenicity with a parallel shape may be a physiological phase and may develop into heterogeneous echogenicity with a spindle shape that is more likely to be pathological. © 2010 John Wiley & Sons A/S.

  18. Tensile properties of craniofacial tendons in the mature and aged zebrafish

    PubMed Central

    Shah, Rishita R.; Nerurkar, Nandan L.; Wang, Calvin; Galloway, Jenna L.

    2015-01-01

    The zebrafish Danio rerio is a powerful model for the study of development, regenerative biology, and human disease. However, the analysis of load-bearing tissues such as tendons and ligaments has been limited in this system. This is largely due to technical limitations that preclude accurate measurement of their mechanical properties. Here, we present a custom tensile testing system that applies nano-Newton scale forces to zebrafish tendons as small as 1 mm in length. Tendon properties were remarkably similar to mammalian tendons, including stress-strain nonlinearity and a linear modulus (515±152 MPa) that aligned closely with mammalian data. Additionally, a simple exponential constitutive law used to describe tendon mechanics was successfully fit to zebrafish tendons; the associated material constants agreed with literature values for mammalian tendons. Finally, mature and aged zebrafish comparisons revealed a significant decline in mechanical function with age. Based on the exponential constitutive model, age related changes were primarily caused by a reduction in nonlinearity (e.g. changes in collagen crimp or fiber recruitment). These findings demonstrate the utility of zebrafish as a model to study tendon biomechanics in health and disease. Moreover, these findings suggest that tendon mechanical behavior is highly conserved across vertebrates. PMID:25665155

  19. Tendon reflex is suppressed during whole-body vibration.

    PubMed

    Karacan, Ilhan; Cidem, Muharrem; Yilmaz, Gizem; Sebik, Oguz; Cakar, Halil Ibrahim; Türker, Kemal Sıtkı

    2016-10-01

    In this study we have investigated the effect of whole body vibration (WBV) on the tendon reflex (T-reflex) amplitude. Fifteen young adult healthy volunteer males were included in this study. Records of surface EMG of the right soleus muscle and accelerometer taped onto the right Achilles tendon were obtained while participant stood upright with the knees in extension, on the vibration platform. Tendon reflex was elicited before and during WBV. Subjects completed a set of WBV. Each WBV set consisted of six vibration sessions using different frequencies (25, 30, 35, 40, 45, 50Hz) applied randomly. In each WBV session the Achilles tendon was tapped five times with a custom-made reflex hammer. The mean peak-to-peak (PP) amplitude of T-reflex was 1139.11±498.99µV before vibration. It decreased significantly during WBV (p<0.0001). The maximum PP amplitude of T-reflex was 1333±515μV before vibration. It decreased significantly during WBV (p<0.0001). No significant differences were obtained in the mean acceleration values of Achilles tendon with tapping between before and during vibration sessions. This study showed that T-reflex is suppressed during WBV. T-reflex suppression indicates that the spindle primary afferents must have been pre-synaptically inhibited during WBV similar to the findings in high frequency tendon vibration studies. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. A passive exoskeleton with artificial tendons: design and experimental evaluation.

    PubMed

    van Dijk, Wietse; van der Kooij, Herman; Hekman, Edsko

    2011-01-01

    We developed a passive exoskeleton that was designed to minimize joint work during walking. The exoskeleton makes use of passive structures, called artificial tendons, acting in parallel with the leg. Artificial tendons are elastic elements that are able to store and redistribute energy over the human leg joints. The elastic characteristics of the tendons have been optimized to minimize the mechanical work of the human leg joints. In simulation the maximal reduction was 40 percent. The performance of the exoskeleton was evaluated in an experiment in which nine subjects participated. Energy expenditure and muscle activation were measured during three conditions: Normal walking, walking with the exoskeleton without artificial tendons, and walking with the exoskeleton with the artificial tendons. Normal walking was the most energy efficient. While walking with the exoskeleton, the artificial tendons only resulted in a negligibly small decrease in energy expenditure. © 2011 IEEE

  1. The role of bone sialoprotein in the tendon-bone insertion.

    PubMed

    Marinovich, Ryan; Soenjaya, Yohannes; Wallace, Gregory Q; Zuskov, Andre; Dunkman, Andrew; Foster, Brian L; Ao, Min; Bartman, Kevin; Lam, Vida; Rizkalla, Amin; Beier, Frank; Somerman, Martha J; Holdsworth, David W; Soslowsky, Louis J; Lagugné-Labarthet, François; Goldberg, Harvey A

    2016-01-01

    Tendons/ligaments insert into bone via a transitional structure, the enthesis, which is susceptible to injury and difficult to repair. Fibrocartilaginous entheses contain fibrocartilage in their transitional zone, part of which is mineralized. Mineral-associated proteins within this zone have not been adequately characterized. Members of the Small Integrin Binding Ligand N-linked Glycoprotein (SIBLING) family are acidic phosphoproteins expressed in mineralized tissues. Here we show that two SIBLING proteins, bone sialoprotein (BSP) and osteopontin (OPN), are present in the mouse enthesis. Histological analyses indicate that the calcified zone of the quadriceps tendon enthesis is longer in Bsp(-/-) mice, however no difference is apparent in the supraspinatus tendon enthesis. In an analysis of mineral content within the calcified zone, micro-CT and Raman spectroscopy reveal that the mineral content in the calcified fibrocartilage of the quadriceps tendon enthesis are similar between wild type and Bsp(-/-) mice. Mechanical testing of the patellar tendon shows that while the tendons fail under similar loads, the Bsp(-/-) patellar tendon is 7.5% larger in cross sectional area than wild type tendons, resulting in a 16.5% reduction in failure stress. However, Picrosirius Red staining shows no difference in collagen organization. Data collected here indicate that BSP is present in the calcified fibrocartilage of murine entheses and suggest that BSP plays a regulatory role in this structure, influencing the growth of the calcified fibrocartilage in addition to the weakening of the tendon mechanical properties. Based on the phenotype of the Bsp(-/-) mouse enthesis, and the known in vitro functional properties of the protein, BSP may be a useful therapeutic molecule in the reattachment of tendons and ligaments to bone. Copyright © 2016 International Society of Matrix Biology. All rights reserved.

  2. The Role of Bone Sialoprotein in the Tendon-Bone Insertion

    PubMed Central

    Marinovich, Ryan; Soenjaya, Yohannes; Wallace, Gregory Q.; Zuskov, Andre; Dunkman, Andrew; Foster, Brian L.; Ao, Min; Bartman, Kevin; Lam, Vida; Rizkalla, Amin; Beier, Frank; Somerman, Martha J.; Holdsworth, David W.; Soslowsky, Louis J.; Lagugné-Labarthet, François; Goldberg, Harvey A.

    2016-01-01

    Tendons/ligaments insert into bone via a transitional structure, the enthesis, which is susceptible to injury and difficult to repair. Fibrocartilaginous entheses contain fibrocartilage in their transitional zone, part of which is mineralized. Mineral-associated proteins within this zone have not been adequately characterized. Members of the Small Integrin Binding Ligand N-Linked Glycoprotein (SIBLING) family are acidic phosphoproteins expressed in mineralized tissues. Here we show that two SIBLING proteins, bone sialoprotein (BSP) and osteopontin (OPN), are present in the mouse enthesis. Histological analyses indicate that the calcified zone of the quadriceps tendon enthesis is longer in Bsp−/− mice, however no difference is apparent in the supraspinatus tendon enthesis. In an analysis of mineral content within the calcified zone, micro-CT and Raman spectroscopy reveal that the mineral content in the calcified fibrocartilage of the quadriceps tendon enthesis are similar between wild type and Bsp−/− mice. Mechanical testing of the patellar tendon shows that while the tendons fail under similar loads, the Bsp−/− patellar tendon is 7.5% larger in cross sectional area than wild type tendons, resulting in a 16.5% reduction in failure stress. However, picrosirius red staining shows no difference in collagen organization. Data collected here indicate that BSP is present in the calcified fibrocartilage of murine entheses and suggest that BSP plays a regulatory role in this structure, influencing the growth of the calcified fibrocartilage in addition to the weakening of the tendon mechanical properties. Based on the phenotype of the Bsp−/− mouse enthesis, and the known in vitro functional properties of the protein, BSP may be a useful therapeutic molecule in the reattachment of tendons and ligaments to bone. PMID:26826499

  3. The Role of Mechanical Loading in Tendon Development, Maintenance, Injury, and Repair

    PubMed Central

    Galloway, Marc T.; Lalley, Andrea L.; Shearn, Jason T.

    2013-01-01

    Tendon injuries often result from excessive or insufficient mechanical loading, impairing the ability of the local tendon cell population to maintain normal tendon function. ➤ The resident cell population composing tendon tissue is mechanosensitive, given that the cells are able to alter the extracellular matrix in response to modifications of the local loading environment. ➤ Natural tendon healing is insufficient, characterized by improper collagen fibril diameter formation, collagen fibril distribution, and overall fibril misalignment. ➤ Current tendon repair rehabilitation protocols focus on implementing early, well-controlled eccentric loading exercises to improve repair outcome. ➤ Tissue engineers look toward incorporating mechanical loading regimens to precondition cell populations for the creation of improved biological augmentations for tendon repair. PMID:24005204

  4. High-resolution US and MR imaging of peroneal tendon injuries.

    PubMed

    Taljanovic, Mihra S; Alcala, Jennifer N; Gimber, Lana H; Rieke, Joshua D; Chilvers, Margaret M; Latt, L Daniel

    2015-01-01

    Injuries of the peroneal tendon complex are common and should be considered in every patient who presents with chronic lateral ankle pain. These injuries occur as a result of trauma (including ankle sprains), in tendons with preexisting tendonopathy, and with repetitive microtrauma due to instability. The peroneus brevis and peroneus longus tendons are rarely torn simultaneously. Several anatomic variants, including a flat or convex fibular retromalleolar groove, hypertrophy of the peroneal tubercle at the lateral aspect of the calcaneus, an accessory peroneus quartus muscle, a low-lying peroneus brevis muscle belly, and an os peroneum, may predispose to peroneal tendon injuries. High-resolution 1.5-T and 3-T magnetic resonance (MR) imaging with use of dedicated extremity coils and high-resolution ultrasonography (US) with high-frequency linear transducers and dynamic imaging are proved to adequately depict the peroneal tendons for evaluation and can aid the orthopedic surgeon in injury management. An understanding of current treatment approaches for partial- and full-thickness peroneal tendon tears, subluxation and dislocation of these tendons with superior peroneal retinaculum (SPR) injuries, intrasheath subluxations, and peroneal tendonopathy and tenosynovitis can help physicians achieve a favorable outcome. Patients with low functional demands do well with conservative treatment, while those with high functional demands may benefit from surgery if nonsurgical treatment is unsuccessful. Radiologists should recognize the normal anatomy and specific pathologic conditions of the peroneal tendons at US and MR imaging and understand the various treatment options for peroneal tendon and SPR superior peroneal retinaculum injuries. Online supplemental material is available for this article. RSNA, 2015

  5. Achilles tendon injury risk factors associated with running.

    PubMed

    Lorimer, Anna V; Hume, Patria A

    2014-10-01

    Research into the nature of overuse Achilles tendon injuries is extensive, yet uncertainty remains around how to identify athletes susceptible to Achilles tendon injury. To identify the strength of evidence for biomechanical risk factors associated with Achilles tendon injuries. SPORTDiscus, CINAHL, Web of Science and PubMed were searched for Achilles tendon injury risk factors and biomechanical measures which are altered in runners with Achilles tendon injuries, excluding ruptures. Fifteen articles were included in the analysis. Two variables, high vertical forces and high arch, showed strong evidence for reduced injury risk. High propulsive forces and running on stiffer surfaces may also be protective. Only one biomechanical variable, high braking force, showed clear evidence for increasing Achilles injury risk. Gait retraining to direct the centre of mass further forward to reduce high braking force could be useful in decreasing the risk of Achilles injury. The majority of biomechanical risk factors examined showed unclear results, which is likely due to the multifactorial nature of Achilles overuse injuries. Many risk factors are related to how the athlete's body interacts with the environment during gait, including ground reaction forces, muscle activity both prior to landing and immediately post ground contact, and joint motion throughout stance. Multiple risk factors have been associated with the development of Achilles tendon injuries in running athletes but most effects remain unclear. Advice for athletes recovering from Achilles tendon injuries could include avoiding soft surfaces and reducing the pace of recovery runs. Orthotic intervention could assist athletes with low arches but modification of pronation should be viewed with caution. Strength training and gait retraining could be beneficial for reducing injury risk.

  6. Traumatic diaphragmatic rupture through the central tendon with herniation of the stomach and coils of small bowel into the pericardial cavity.

    PubMed

    Nwafor, I A; Eze, J C; Aminu, M B

    2011-01-01

    Traumatic diaphragmatic rupture through the central tendon with herniation of the stomach and coils of small bowel into the pericardial cavity. Case note of a patient managed for traumatic diaphragmatic rupture through the central tendon with herniation of the stomach and coils of small bowel into the pericardial cavity was used with a review of relevant literature. A 49-year old civil engineer who presented with 2-year history of easy fatigability and palpitations as well as a 6-month history of hypertension and was initially managed as a case dilated cardiomyopathy to rule out incipient CCF secondary to hypertension, was evaluated and found to have chronic diaphragmatic hernia through the central tendon with evisceration of the stomach and coils of the small bowel into the pericardial cavity. Though there was history of motor vehicle crash preceding the development of the symptoms, but the long history of effort dyspnoea and palpitations added to enlarged cardiac silhouette on posterior anterior chest x-ray, a diagnostic challenge was posed which was resolved by thoracoabdominal CT scan. Patient had left sided posteriorlateral thoracotomy via 7h intercostal space followed with reduction of thq stomach and coils of small bowel after careful adhesiolysis and repair of the defect in double layers. High index of suspicion is very important in the diagnosis of diaphragmatic central tendon injury considering the rarity of the injury and diagnostic challenges it poses in chronic form. However, where the facilities are available, CT scan and 2-D echo will most of the time clinch the diagnosis; also is upper gastrointestinal series.

  7. Incidence and clinical outcomes of tendon rupture following distal radius fracture.

    PubMed

    White, Brian D; Nydick, Jason A; Karsky, Dawnne; Williams, Bailee D; Hess, Alfred V; Stone, Jeffrey D

    2012-10-01

    To evaluate the incidence of tendon rupture after nonoperative and operative management of distal radius fractures, report clinical outcomes after tendon repair or transfer, and examine volar plate and dorsal screw prominence as a predictor of tendon rupture. We performed a retrospective chart review on patients treated for tendon rupture after distal radius fracture. We evaluated active range of motion, Disabilities of Arm, Shoulder, and Hand score, grip strength, and pain score, and performed radiographic evaluation of volar plate and dorsal screw prominence in both the study group and a matched control group. There were 6 tendon ruptures in 1,359 patients (0.4%) treated nonoperatively and 8 tendon ruptures in 999 patients (0.8%) treated with volar plate fixation. At the time of final follow-up, regardless of treatment, we noted that patients had minimal pain and excellent motion and grip strength. Mean Disabilities of the Shoulder, Arm, and Hand scores were 6 for patients treated nonoperatively and 4 for those treated with volar plating. We were unable to verify volar plate or dorsal screw prominence as independent risk factors for tendon rupture after distal radius fractures. However, we recommend continued follow-up and plate removal for symptomatic patients who have volar plate prominence or dorsal screw prominence. In the event of tendon rupture, we report excellent clinical outcomes after tendon repair or tendon transfer. Therapeutic IV. Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  8. Enhanced tendon-to-bone repair through adhesive films.

    PubMed

    Linderman, Stephen W; Golman, Mikhail; Gardner, Thomas R; Birman, Victor; Levine, William N; Genin, Guy M; Thomopoulos, Stavros

    2018-04-01

    Tendon-to-bone surgical repairs have unacceptably high failure rates, possibly due to their inability to recreate the load transfer mechanisms of the native enthesis. Instead of distributing load across a wide attachment footprint area, surgical repairs concentrate shear stress on a small number of suture anchor points. This motivates development of technologies that distribute shear stresses away from suture anchors and across the enthesis footprint. Here, we present predictions and proof-of-concept experiments showing that mechanically-optimized adhesive films can mimic the natural load transfer mechanisms of the healthy attachment and increase the load tolerance of a repair. Mechanical optimization, based upon a shear lag model corroborated by a finite element analysis, revealed that adhesives with relatively high strength and low stiffness can, theoretically, strengthen tendon-to-bone repairs by over 10-fold. Lap shear testing using tendon and bone planks validated the mechanical models for a range of adhesive stiffnesses and strengths. Ex vivo human supraspinatus repairs of cadaveric tissues using multipartite adhesives showed substantial increase in strength. Results suggest that adhesive-enhanced repair can improve repair strength, and motivate a search for optimal adhesives. Current surgical techniques for tendon-to-bone repair have unacceptably high failure rates, indicating that the initial repair strength is insufficient to prevent gapping or rupture. In the rotator cuff, repair techniques apply compression over the repair interface to achieve contact healing between tendon and bone, but transfer almost all force in shear across only a few points where sutures puncture the tendon. Therefore, we evaluated the ability of an adhesive film, implanted between tendon and bone, to enhance repair strength and minimize the likelihood of rupture. Mechanical models demonstrated that optimally designed adhesives would improve repair strength by over 10-fold

  9. Homologies of the transversospinalis muscles in the anterior presacral region of Sauria (crown Diapsida).

    PubMed

    Tsuihiji, Takanobu

    2005-02-01

    Homologies of muscles of the m. transversospinalis group in the dorsal and cervical regions in Sauria are established based on detailed dissections and published accounts of lepidosaurs, crocodylians, and birds. Attachments and directions of tendons comprising this muscle group are fairly conserved among the saurian clades, enabling rather robust inferences on muscle homologies. The innervation pattern indicates that mm. ascendentes are the most lateral muscles of the m. transversospinalis group in Aves, and are inferred to be homologous with the crocodylian m. tendinoarticularis based on their topological similarities. It is suggested here that the lepidosaurian articulo-parietalis part of m. longissimus cervico-capitis actually belongs to the m. transversospinalis group because its tendons of origin are shared with those of m. semispinalis. The avian m. complexus and the lateral part of the crocodylian m. transversospinalis capitis have origins and insertions similar to this lepidosaurian muscle, and are proposed to be homologous with the latter. In some birds, m. longus colli dorsalis, pars profunda continues directly into the anterior cervical region as m. splenius accessorius, suggesting a serially homologous relationship. Similarly, m. splenius anticus continues anteriorly from m. longus colli dorsalis, pars cranialis, and both of these muscles lie dorsal to m. splenius accessorius. Therefore, the currently used nomenclature that regards m. splenius accessorius as a part of m. longus colli dorsalis, pars cranialis and that regards m. splenius anticus as a part of the former muscle does not accurately reflect the serial homologies among these muscles and may not be justified. Copyright 2004 Wiley-Liss, Inc.

  10. Structural and Ultrastructural Characteristics of Bone-Tendon Junction of the Calcaneal Tendon of Adult and Elderly Wistar Rats

    PubMed Central

    Cury, Diego Pulzatto; Dias, Fernando José; Miglino, Maria Angélica; Watanabe, Ii-sei

    2016-01-01

    Tendons are transition tissues that transfer the contractile forces generated by the muscles to the bones, allowing movement. The region where the tendon attaches to the bone is called bone-tendon junction or enthesis and may be classified as fibrous or fibrocartilaginous. This study aims to analyze the collagen fibers and the cells present in the bone-tendon junction using light microscopy and ultrastructural techniques as scanning electron microscopy and transmission electron microscopy. Forty male Wistar rats were used in the experiment, being 20 adult rats at 4 months-old and 20 elderly rats at 20 months-old. The hind limbs of the rats were removed, dissected and prepared to light microscopy, transmission electron microscopy and scanning electron microscopy. The aging process showed changes in the collagen fibrils, with a predominance of type III fibers in the elderly group, in addition to a decrease in the amount of the fibrocartilage cells, fewer and shorter cytoplasmic processes and a decreased synthetic capacity due to degradation of the organelles involved in synthesis. PMID:27078690

  11. Structural and Ultrastructural Characteristics of Bone-Tendon Junction of the Calcaneal Tendon of Adult and Elderly Wistar Rats.

    PubMed

    Cury, Diego Pulzatto; Dias, Fernando José; Miglino, Maria Angélica; Watanabe, Ii-sei

    2016-01-01

    Tendons are transition tissues that transfer the contractile forces generated by the muscles to the bones, allowing movement. The region where the tendon attaches to the bone is called bone-tendon junction or enthesis and may be classified as fibrous or fibrocartilaginous. This study aims to analyze the collagen fibers and the cells present in the bone-tendon junction using light microscopy and ultrastructural techniques as scanning electron microscopy and transmission electron microscopy. Forty male Wistar rats were used in the experiment, being 20 adult rats at 4 months-old and 20 elderly rats at 20 months-old. The hind limbs of the rats were removed, dissected and prepared to light microscopy, transmission electron microscopy and scanning electron microscopy. The aging process showed changes in the collagen fibrils, with a predominance of type III fibers in the elderly group, in addition to a decrease in the amount of the fibrocartilage cells, fewer and shorter cytoplasmic processes and a decreased synthetic capacity due to degradation of the organelles involved in synthesis.

  12. Initial experience with visualizing hand and foot tendons by dual-energy computed tomography.

    PubMed

    Deng, Kai; Sun, Cong; Liu, Cheng; Ma, Rui

    2009-01-01

    To assess the feasibility of visualizing hand and foot tendons by dual-energy computed tomography (CT). Twenty patients who suffered from hand or feet pains were scanned on dual-source CT (Definition, Forchheim, Germany) with dual-energy mode at tube voltages of 140 and 80 kV and a corresponding ratio of 1:4 between tube currents. The reconstructed images were postprocessed by volume rendering techniques (VRT) and multiplanar reconstruction (MPR). All of the suspected lesions were confirmed by surgery or follow-up studies. Twelve patients (total of 24 hands and feet, respectively) were found to be normal and the other eight patients (total of nine hands and feet, respectively) were found abnormal. Dual-energy techniques are very useful in visualizing tendons of the hands and feet, such as flexor pollicis longus tendon, flexor digitorum superficialis/profundus tendon, Achilles tendon, extensor hallucis longus tendon, and extensor digitorum longus tendon, etc. It can depict the whole shape of the tendons and their fixation points clearly. Peroneus longus tendon in the sole of the foot was not displayed very well. The distal ends of metacarpophalangeal joints with extensor digitoium tendon and extensor pollicis longus tendon were poorly shown. The lesions of tendons such as the circuitry, thickening, and adherence were also shown clearly. Dual-energy CT offers a new method to visualize tendons of the hand and foot. It could clearly display both anatomical structures and pathologic changes of hand and foot tendons.

  13. Current Concepts in Examination and Treatment of Elbow Tendon Injury

    PubMed Central

    Ellenbecker, Todd S.; Nirschl, Robert; Renstrom, Per

    2013-01-01

    Context: Injuries to the tendons of the elbow occur frequently in the overhead athlete, creating a significant loss of function and dilemma to sports medicine professionals. A detailed review of the anatomy, etiology, and pathophysiology of tendon injury coupled with comprehensive evaluation and treatment information is needed for clinicians to optimally design treatment programs for rehabilitation and prevention. Evidence Acquisitions: The PubMed database was searched in January 2012 for English-language articles pertaining to elbow tendon injury. Results: Detailed information on tendon pathophysiology was found along with incidence of elbow injury in overhead athletes. Several evidence-based reviews were identified, providing a thorough review of the recommended rehabilitation for elbow tendon injury. Conclusions: Humeral epicondylitis is an extra-articular tendon injury that is common in athletes subjected to repetitive upper extremity loading. Research is limited on the identification of treatment modalities that can reduce pain and restore function to the elbow. Eccentric exercise has been studied in several investigations and, when coupled with a complete upper extremity strengthening program, can produce positive results in patients with elbow tendon injury. Further research is needed in high-level study to delineate optimal treatment methods. PMID:24427389

  14. Modified rerouting procedure for failed peroneal tendon dislocation surgery.

    PubMed

    Gaulke, R; Hildebrand, F; Panzica, M; Hüfner, T; Krettek, C

    2010-04-01

    Recurrent dislocation of the peroneal tendons following operative treatment is relatively uncommon, but can be difficult to treat. We asked whether subligamental transposition of the peroneus brevis tendon, fibular grooving, and reattachment of the superior peroneal retinaculum for failed peroneal tendon dislocation surgery would achieve a stable fixation of the peroneal tendons and whether there would be restrictions of ROM or instability of the hindfoot. We reviewed six female patients (mean age, 24.5 years) with general laxity of joints preoperatively and at 6 weeks and 3, 6, and 12 months postoperatively. Within 1 year postoperatively no recurrence was found. In two ankles the extension was restricted 5 degrees to 10 degrees . In another pronation and supination was restricted 5 degrees each. Stability of the ankle increased in four patients and stayed unchanged in two. AOFAS score increased from a mean value of 36 +/- 20.6 preoperatively to 90 +/- 7 postoperatively at 1 year. We conclude transposition of the peroneus brevis tendon is a reasonable treatment for failed peroneal tendon dislocation surgery. Level IV, therapeutic study (prospective case series). See Guidelines for Authors for a complete description of levels of evidence.

  15. Magnesium inference screw supports early graft incorporation with inhibition of graft degradation in anterior cruciate ligament reconstruction

    PubMed Central

    Cheng, Pengfei; Han, Pei; Zhao, Changli; Zhang, Shaoxiang; Zhang, Xiaonong; Chai, Yimin

    2016-01-01

    Patients after anterior cruciate ligament (ACL) reconstruction surgery commonly encounters graft failure in the initial phase of rehabilitation. The inhibition of graft degradation is crucial for the successful reconstruction of the ACL. Here, we used biodegradable high-purity magnesium (HP Mg) screws in the rabbit model of ACL reconstruction with titanium (Ti) screws as a control and analyzed the graft degradation and screw corrosion using direct pull-out tests, microCT scanning, and histological and immunohistochemical staining. The most noteworthy finding was that tendon graft fixed by HP Mg screws exhibited biomechanical properties substantially superior to that by Ti screws and the relative area of collagen fiber at the tendon-bone interface was much larger in the Mg group, when severe graft degradation was identified in the histological analysis at 3 weeks. Semi-quantitative immunohistochemical results further elucidated that the MMP-13 expression significantly decreased surrounding HP Mg screws with relatively higher Collagen II expression. And HP Mg screws exhibited uniform corrosion behavior without displacement or loosening in the femoral tunnel. Therefore, our results demonstrated that Mg screw inhibited graft degradation and improved biomechanical properties of tendon graft during the early phase of graft healing and highlighted its potential in ACL reconstruction. PMID:27210585

  16. Magnesium inference screw supports early graft incorporation with inhibition of graft degradation in anterior cruciate ligament reconstruction

    NASA Astrophysics Data System (ADS)

    Cheng, Pengfei; Han, Pei; Zhao, Changli; Zhang, Shaoxiang; Zhang, Xiaonong; Chai, Yimin

    2016-05-01

    Patients after anterior cruciate ligament (ACL) reconstruction surgery commonly encounters graft failure in the initial phase of rehabilitation. The inhibition of graft degradation is crucial for the successful reconstruction of the ACL. Here, we used biodegradable high-purity magnesium (HP Mg) screws in the rabbit model of ACL reconstruction with titanium (Ti) screws as a control and analyzed the graft degradation and screw corrosion using direct pull-out tests, microCT scanning, and histological and immunohistochemical staining. The most noteworthy finding was that tendon graft fixed by HP Mg screws exhibited biomechanical properties substantially superior to that by Ti screws and the relative area of collagen fiber at the tendon-bone interface was much larger in the Mg group, when severe graft degradation was identified in the histological analysis at 3 weeks. Semi-quantitative immunohistochemical results further elucidated that the MMP-13 expression significantly decreased surrounding HP Mg screws with relatively higher Collagen II expression. And HP Mg screws exhibited uniform corrosion behavior without displacement or loosening in the femoral tunnel. Therefore, our results demonstrated that Mg screw inhibited graft degradation and improved biomechanical properties of tendon graft during the early phase of graft healing and highlighted its potential in ACL reconstruction.

  17. Evaluation of the potential application of three different biomaterials combined with bone morphological proteins for enhancing tendon-bone integration.

    PubMed

    Pan, Weimin; Cao, Zheng; Li, Dan; Zhang, Mingjun

    2013-04-01

    Secure tendon-bone integration is crucial for successful anterior cruciate ligament (ACL) reconstruction. Previous studies have applied different types of biomaterial or biomaterial combined with bone-growth factors to enhance tendon-bone integration. However, which approach is better remains controversial. This comparison evaluation could help identify a suitable composite biomaterial for osteointegration of grafted tendon. Three different composite biomaterials mixed with bone morphological proteins (BMPs) were fabricated. The in vitro study investigates cell metabolism, osteogenic gene expression and the growth behaviour of bone marrow stromal cells (BMSCs) on fibrin glue-BMPs (FGB), calcium phosphate cement-BMPs (CPCB) and recombined bone xenograft (RBX), which are commercially, clinically available biomaterials. Meanwhile, the changes in the physical, morphological and mechanical properties between the three composites and the original biomaterials were also observed. The in vivo study mainly examined the osteogenic ability of the three composites through rat ectopic testing. The porosity structure of three biomaterials was improved after being combined with BMPs powder for SEM observation, and the setting times of the injectable composites were not significantly delayed. More importantly, there were no significant decreases in compressive strength between the three composite biomaterials and the original biomaterials. The highest proliferation rate of BMSCs was found in the RBX group, followed by the CPCB and FGB groups. BMSCs seeded onto an RBX showed the highest alkaline phosphatase (ALPase) activity and gene expression of collagen I (P < 0.05). Histological examination showed endochondral new bone formation in the specimens of all groups, but the ALPase activity of newly formed tissue in the RBX group showed the highest level (P < 0.01). Our results indicate that RBX seems to be a very good choice for accelerating tendon-bone integration, and CPCB also has

  18. Has platelet-rich plasma any role in anterior cruciate ligament allograft healing?

    PubMed

    Nin, Juan Ramón Valentí; Gasque, Gonzalo Mora; Azcárate, Andrés Valentí; Beola, Jesús Dámaso Aquerreta; Gonzalez, Milagros Hernandez

    2009-11-01

    The aim of this study was to evaluate and compare the clinical and inflammatory parameters with the addition of platelet-derived growth factor (PDGF) in primary anterior cruciate ligament (ACL) reconstruction with bone-patellar tendon-bone allograft. We prospectively randomized 100 patients undergoing arthroscopic patellar tendon allograft ACL reconstruction to a group in whom platelet-enriched gel was used (n = 50) and a non-gel group (n = 50). The platelet concentration was 837 x 10(3)/mm(3), and the gel was introduced inside the graft and the tibial tunnel. Demographic data were comparable between groups. The mean follow-up was 24 months for both groups and included a history, clinical evaluation with the International Knee Documentation Committee score, radiographs, and magnetic resonance imaging. There were no differences in the number of associated injuries. The results did not show any statistically significant differences between the groups for inflammatory parameters (perimeters of the knee and C-reactive protein level), magnetic resonance imaging appearance of the graft, and clinical evaluation scores (visual analog scale, International Knee Documentation Committee, and KT-1000 arthrometer [MEDmetric, San Diego, CA]). At this time, the therapeutic role of PDGF in ACL reconstruction remains unclear. The use of PDGF, on the graft and inside the tibial tunnel, in patients treated with bone-patellar tendon-bone allografts has no discernable clinical or biomechanical effect at 2 years' follow-up. More clinical studies will be needed to show the efficacy and use of these factors in daily practice in ACL reconstruction. Level I, prospective, randomized, double-blind study.

  19. A wrist tendon travel assessment of hand movements associated with industrial repetitive activities.

    PubMed

    Ugbolue, U Chris; Nicol, Alexander C

    2012-01-01

    To investigate slow and fast paced industrial activity hand repetitive movements associated with carpal tunnel syndrome where movements are evaluated based on finger and wrist tendon travel measurements. Nine healthy subjects were recruited for the study aged between 23 and 33 years. Participants mimicked an industrial repetitive task by performing the following activities: wrist flexion and extension task, palm open and close task; and pinch task. Each task was performed for a period of 5 minutes at a slow (0.33 Hz) and fast (1 Hz) pace for a duration of 3 minutes and 2 minutes respectively. Tendon displacement produced higher flexor digitorum superficialis (FDS) tendon travel when compared to the flexor digitorum profundus (FDP) tendons. The left hand mean (SD) tendon travel for the FDS tendon and FDP tendon were 11108 (5188) mm and 9244 (4328) mm while the right hand mean tendon travel (SD) for the FDS tendon and FDP tendon were 9225 (3441) mm and 7670 (2856) mm respectively. Of the three tasks mimicking an industrial repetitive activity, the wrist flexion and extension task produced the most tendon travel. The findings may be useful to researchers in classifying the level of strenuous activity in relation to tendon travel.

  20. Hamstring autograft versus soft-tissue allograft in anterior cruciate ligament reconstruction: a systematic review and meta-analysis of randomized controlled trials.

    PubMed

    Cvetanovich, Gregory L; Mascarenhas, Randy; Saccomanno, Maristella F; Verma, Nikhil N; Cole, Brian J; Bush-Joseph, Charles A; Bach, Bernard R

    2014-12-01

    To compare outcomes of anterior cruciate ligament (ACL) reconstruction with hamstring autograft versus soft-tissue allograft by systematic review and meta-analysis. A systematic review of randomized controlled studies comparing hamstring autograft with soft-tissue allograft in ACL reconstruction was performed. Studies were identified by strict inclusion and exclusion criteria. Descriptive statistics were reported. Where possible, the data were pooled and a meta-analysis was performed using RevMan software (The Nordic Cochrane Centre, The Cochrane Collaboration, Copenhagen, Denmark). Dichotomous data were reported as risk ratios, whereas continuous data were reported as standardized mean differences and 95% confidence intervals. Heterogeneity was assessed by use of I(2) for each meta-analysis. Study methodologic quality was analyzed with the Modified Coleman Methodology Score and Jadad scale. Five studies with 504 combined patients (251 autograft and 253 allograft; 374 male and 130 female patients) with a mean age of 29.9 ± 2.2 years were included. The allografts used were fresh-frozen hamstring, irradiated hamstring, mixture of fresh-frozen and cryopreserved hamstring, fresh-frozen tibialis anterior, and fresh-frozen Achilles tendon grafts without bone blocks. The mean follow-up period was 47.4 ± 26.9 months, with a mean follow-up rate of 83.3% ± 8.6%. Two studies found a longer operative time with autograft than with allograft (77.1 ± 2.0 minutes v 59.9 ± 0.9 minutes, P = .008). Meta-analysis showed no statistically significant differences between autografts and allografts for any outcome measures (P > .05 for all tests). One study found significantly greater laxity for irradiated allograft than for autograft. The methodologic quality of the 5 studies was poor, with a mean Modified Coleman Methodology Score of 54.4 ± 6.9 and mean Jadad score of 1.6 ± 1.5. On the basis of this systematic review and meta-analysis of 5 randomized controlled trials, there is